WorldWideScience

Sample records for shot mr-cholangiopancreatography mrcp

  1. Imaging of the normal and abnormal pancreaticobiliary system with single-shot MR cholangiopancreatography: a pictorial review

    International Nuclear Information System (INIS)

    Little, A. F.; Smith, P.J.; Lee, W.K.; Hennessy, O.F.; Lourensz, M.E.; Desmond, P.V.; Banting, S.W.

    1999-01-01

    Magnetic resonance cholangiopancreatography (MRCP) is a rapidly evolving non-invasive imaging modality that produces images of the pancreatic duct and binary tree without the need for intravenous or oral contrast. The images are equivalent to those from endoscopic retrograde cholangiopancreatography (ERCP), but the non-invasive acquisition avoids the morbidity and mortality associated with diagnostic ERCP. Magnetic resonance cholangiopancreatography is indicated in patients who require only a diagnostic ERCP, who fail an ERCP or who are unable to undergo ERCP due to altered post-surgical anatomy. Other evolving indications include triaging of patients with obstructive jaundice into percutaneous or endoscopic management drainage pathways depending on the site, length and nature of the duct obstruction, thereby potentially decreasing the number of failed or unsuccessful ERCP. Preoperative identification of anomalous binary anatomy and choledocholithiasis prior to laparoscopic cholecystectomy promise to modify the pre-operative and operative management of the patient in order to minimize the risk of duct injury and unnecessary intra-operative dissection and cholangiography. The advantages of the technique include its non-invasiveness, the absence of contrast administration, its relative operator independence and the ability to evaluate both sides of an obstructed duct, thereby accurately evaluating stricture morphology and length. The disadvantages of MRCP compared to ERCP include its lack of an immediate therapeutic solution to duct obstruction, procedural cost, unit availability and the inability to evaluate patients with pacemakers or ferromagnetic implants. Copyright (1999) Blackwell Science Pty Ltd

  2. Comparison of respiratory-triggered 3-D fast spin-echo and single-shot fast spin-echo radial slab MR cholangiopancreatography images in children

    Energy Technology Data Exchange (ETDEWEB)

    Chavhan, Govind B.; Almehdar, Abeer; Gupta, Sumeet [The Hospital for Sick Children and University of Toronto, Department of Diagnostic Imaging, Toronto (Canada); Moineddin, Rahim [University of Toronto, Department of Family and Community Medicine, Toronto (Canada); Babyn, Paul S. [Royal University Hospital, Department of Medical Imaging, Saskatoon (Canada)

    2013-09-15

    The two most commonly performed magnetic resonance cholangiopancreatography (MRCP) sequences, 3-D fast spin-echo (3-D FSE) and single-shot fast spin-echo radial slabs (radial slabs), have not been compared in children. The purpose of this study was to compare 3-D FSE and radial slabs MRCP sequences on a 3-T scanner to determine their ability to show various segments of pancreaticobiliary tree and presence of artifacts in children. We reviewed 79 consecutive MRCPs performed in 74 children on a 3-T scanner. We noted visibility of major ducts on 3-D FSE and radial slabs. We noted the order of branching of ducts in the right and left hepatic ducts and the degree of visibility of the pancreatic duct. Statistical analysis was performed using McNemar and signed rank tests. There was no significant difference in the visibility of major bile ducts and the order of branching in the right hepatic lobe between sequences. A higher order of branching in the left lobe was seen on radial slabs than 3-D FSE (mean order of branching 2.82 versus 2.27; P-value = 0.0002). The visibility of pancreatic duct was better on radial slabs as compared to 3-D FSE (mean value of 1.53 vs. 0.90; P-value < 0.0001). 3-D FSE sequence was artifact-free in 25/79 (31.6%) MRCP exams as compared to radial slabs, which were artifact-free in 18/79 (22.8%) MRCP exams (P-value = 0.0001). There is no significant difference in the visibility of major bile ducts between 3-D FSE and radial slab MRCP sequences at 3-T in children. However, radial slab MRCP shows a higher order of branching in the left hepatic lobe and superior visibility of the pancreatic duct than 3-D FSE. (orig.)

  3. 3 T MR cholangiopancreatography appearances of biliary ascariasis

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Z.X., E-mail: hangzhoudzx73@126.co [Department of Radiology, Zhejiang Provincial People' s Hospital, Hangzhou (China); Yuan, J.H. [Department of Radiology, Zhejiang Provincial People' s Hospital, Hangzhou (China); Chong, V. [Department of Diagnostic Imaging, National University Health System, Yong Loo Lin School of Medicine, National University of Singapore (Singapore); Zhao, D.J. [Department of Hepatobiliary Surgery, Zhejiang Provincial People' s Hospital, Hangzhou (China); Chen, F.H.; Li, Y.M. [Department of Radiology, Zhejiang Provincial People' s Hospital, Hangzhou (China)

    2011-03-15

    Aim: To evaluate the 3 T MR cholangiopancreatography (MRCP) appearances of biliary ascariasis. Materials and methods: Nine patients with a MRCP diagnosis of biliary ascariasis were reviewed. All patients had endoscopic retrograde cholangiopancreatography (ERCP) or surgical confirmation of the disease. Results: On thin-slab MRCP imaging, Ascaris worms are clearly demarcated within the biliary tree. All the identified worms demonstrated a characteristic three-parallel-lines appearance. The middle high-signal intensity line is sandwiched between two low-signal intensity lines and they are in turn surrounded by high signal bile. On thick-slab MRCP the worms also show the three-line sign but with less clarity. However, thick-slab MRCP has the advantage of providing three-dimensional ERCP-like images of the pancreaticobiliary system. Conclusion: The 'three-line' sign appears to be a characteristic sign of biliary ascariasis on 3 T MRCP.

  4. MR cholangiopancreatography. Comparison of images obtained with 1.0 and 1.5 tesla units

    International Nuclear Information System (INIS)

    Yasui, Masayasu; Ito, Katsuyoshi; Koike, Shinji; Matsunaga, Naofumi

    2002-01-01

    The purpose of this study was to compare the image quality and visualization obtained in MR cholangiopancreatography (MRCP) using different high-field strength (1.0 vs. 1.5 Tesla) MR units and to assess the effect of field strength on MRCP. This study population included 10 healthy volunteers and 37 patients suspected of having pancreatobiliary diseases. MRCP images were obtained using two MR units with different high-field strengths (1.0 and 1.5 Tesla), with half-Fourier acquisition single-shot turbo spin-echo (HASTE) and rapid acquisition by relaxation enhancement (RARE) sequences. The image quality and visualization of each portion of the pancreatobiliary system were graded and recorded using a four-point scale. Additionally, the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured. The SNR and CNR in HASTE sequences acquired with the 1.5 Tesla (T) unit were significantly higher than those acquired with the 1.0 T unit (p=0.001). In qualitative analysis, there were no statistically significant differences in image quality or visualization of the ducts in either HASTE or RARE sequences between 1.0 T and 1.5 T. Our study showed that visual image quality provided by MRCP was equivalent at 1.0 and 1.5 T. (author)

  5. MR cholangiopancreatography diagnosis for cholangitis caused by clonorchis sinensis

    International Nuclear Information System (INIS)

    Cui Bing; Hu Qiugen; Wang Yan

    2003-01-01

    Objective: To evaluate the MR cholangiopancreatography (MRCP) diagnosis for cholangitis caused by clonorchis sinensis. Methods: Fifty-four cases with cholangitis caused by clonorchis sinensis were examined by MRCP (3D FASE-Heavy T 2 WI sequence). The results of MRCP were compared with that of ERCP, laparoscopy, and pathology. Results: The diagnostic accuracy for the cause of the disease was 88.9%. Main findings on MRCP included slight dilation of the intra-hepatic biliary duct (n=46), small cystiform dilation of peripheral biliary ending (n=43), extra-hepatic biliary dilations (n=15) and strictures (n=19), and low signal intensity filling defect in the common bile duct and gallbladder (n=6). Conclusion: MRCP of biliary tree images can be obtained with 3D FASE Heavy T 2 WI sequence in considerable details. The characteristic of the cholangitis caused by clonorchis sinensis on MRCP was the slight dilation or stricture of extensive intra-hepatic biliary duct, combined with small cystiform dilation of peripheral biliary ending. MRCP was an ideal technique in diagnosing the disease

  6. MR cholangiopancreatography in children: feasibility, safety, and initial experience

    International Nuclear Information System (INIS)

    Delaney, Lisa; Karmazyn, Boaz; Akisik, M.F.; Jennings, S.G.; Applegate, Kimberly E.

    2008-01-01

    The indications for MR cholangiopancreatography (MRCP) in children, and its safety and findings, might differ from those in adults and are not well described. To investigate the safety, feasibility, and accuracy of MRCP in children. We reviewed all prospective MRCP reports, noting the indication, the use of secretin, endoscopic retrograde cholangiopancreatography (ERCP) findings, and patient outcomes. Two readers reviewed each MRCP study by consensus to rate duct visualization and compare pancreatic duct sizes before and after secretin administration (paired t-test). The likelihood of a normal versus an abnormal MRCP study was compared by gender, pancreatitis as the primary indication, secretin use, and whether ERCP was performed (Fisher's exact test), as well as age (t-test). A total of 85 MRCP studies were performed in children (mean age 10.3 years), most commonly for evaluation of pancreatitis (n=47, 55%); 41 (48%) used secretin and 39 (46%) used a negative oral contrast agent. Of the 85 studies, 72 (85%) had excellent image quality and 43 were normal. ERCP was performed after 16 of the 85 MRCP studies (19%); the diagnoses were concordant with those of MRCP in 13 (81%). There were 42 abnormal MRCP studies, and these were more likely to be in girls (P=0.03) and in children who had undergone ERCP (P<0.01). Secretin and the negative oral contrast agent were well-tolerated. Secretin improved duct visualization (P<0.001). MRCP safely and accurately depicted pancreaticobiliary anatomy in children. The use of secretin improved visualization of the pancreatic duct. (orig.)

  7. On the appearance of bile in clinical MR cholangiopancreatography

    International Nuclear Information System (INIS)

    Haakansson, K.; Christoffersson, J.O.; Leander, P.; Ekberg, O.; Haakansson, H.O.

    2002-01-01

    Purpose: To study the appearance of bile in clinical MR cholangiopancreatography (MRCP) with special reference to its chemical and physical properties. Material and Methods: Gallbladder bile was collected during surgery from 38 patients and studied with respect to chemical constituents. The relaxation rates 1/T1 and 1/T2 of bile were also determined in vitro. In 16 of these 38 patients, abdominal imaging was performed using MRCP as well as T1-weighted GE sequences. Results: For 9 of the 13 chemical parameters studied, a positive significant correlation with 1/T1 as well as 1/T2 was found. The median relaxation rates 1/T1 and 1/T2 were 0.76 and 1.48/s, respectively. The corresponding ranges were 0.38-3.13/s and 0.70-5.75/s, respectively. On the MRCP images a few patients showed gallbladder of poor visibility due to low signal-to-noise ratio. This coincided with a high relaxation rate 1/T2 of bile. On the T1-weighted GE sequences a few patients showed hyperintense gallbladder relative to liver, coinciding with high relaxation rates 1/T1 of bile. Conclusion: Bile was found to show a large interindividual variation with respect to relaxation rates 1/T1 and 1/T2. The relaxation rates increased with increasing amounts of substances in the bile. For some patients (11%) MRCP imaging is unsuccessful due to high relaxation rate of bile

  8. Gadopentetate dimeglumine-enhanced MR cholangiopancreatography in infants with cholestasis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Mi-Jung; Kim, Myung-Joon [Yonsei University, College of Medicine, Department of Radiology and Research Institute of Radiological Science, Severance Children' s Hospital, Seoul (Korea, Republic of); Severance Pediatric Liver Disease Research Group, Seoul (Korea, Republic of); Yoon, Choon-Sik [Yonsei University, College of Medicine, Department of Radiology, Gangnam Severance Hospital, Seoul (Korea, Republic of); Chung, Yong Eun [Yonsei University, College of Medicine, Department of Radiology and Research Institute of Radiological Science, Severance Children' s Hospital, Seoul (Korea, Republic of); Han, Seok Joo [Yonsei University, College of Medicine, Department of Pediatric Surgery, Severance Children' s Hospital, Seoul (Korea, Republic of); Severance Pediatric Liver Disease Research Group, Seoul (Korea, Republic of); Koh, Hong [Yonsei University, College of Medicine, Department of Pediatric Gastroenterology, Hepatology, and Nutrition, Severance Children' s Hospital, Seoul (Korea, Republic of); Severance Pediatric Liver Disease Research Group, Seoul (Korea, Republic of)

    2011-04-15

    Biliary atresia (BA) is a progressive, obliterative cholangiopathy that occurs in neonates with hepatic portoenterostomy the treatment of choice, but early surgery is important for optimum outcomes. MRI, including MR cholangiopancreatography (MRCP) may be a diagnostically useful alternative to US, but the heavily T2-weighted sequences used include not only bile duct signals, but also other heterogeneously high signal intensities from surrounding structures. To evaluate the effects of gadolinium when used to decrease background signal intensity on T2-weighted MR cholangiopancreatography (MRCP) in infants and to evaluate the qualitative improvement of the depiction of the common bile duct (CBD) for evaluating neonatal cholestasis. Our Institutional Review Board approved this prospective study. MRCP was performed with gadopentetate dimeglumine injection using a 1.5-T scanner. Pre- and postcontrast MRCP images were compared. Forty-nine infants (male:female = 21:28; age 0-12 months, mean 2.3) were included. The final diagnoses were biliary atresia (BA) in 28 cases and non-BA in 21. Quantitative analysis was conducted using region-of-interest measurements of mean signal intensities of the liver, pancreatic head and gallbladder (if defined). Qualitative analysis was performed by four radiologists who subjectively scored image confidence in the presence of CBD on a 4-point scale (0 for definitely absent, 1 for probably absent, 2 for probably present, and 3 for definitely present). The signal-to-noise ratios were significantly decreased in the liver and pancreatic head after contrast medium enhancement (mean 5.7{yields}4.0 in liver and mean 44.9{yields}12.7 in the pancreatic head; P < 0.0001), and this finding was constant in both the BA and the non-BA group. The mean confidence score in the presence of CBD decreased in the BA group (0.9{yields}0.5; P < 0.0001), but did not change significantly in the non-BA group (2.0{yields}2.1; P = 0.459) after contrast medium

  9. Primary biliary cirrhosis: Evaluation with T2-weighted MR imaging and MR cholangiopancreatography

    International Nuclear Information System (INIS)

    Haliloglu, Nuray; Erden, Ayse; Erden, Ilhan

    2009-01-01

    Purpose: The aim of this retrospective study is to evaluate the role of T2-weighted MR imaging (MRI) and MR cholangiopancreatography (MRCP) findings in the diagnosis of primary biliary cirrhosis (PBC). Materials and methods: The following T2-weighted MRI and MRCP findings: segmental hepatic atrophy/hypertrophy, irregular liver surface, parenchymal lace-like fibrosis, rounded low signal intensity lesions centering portal vein branches (periportal halo sign), periportal hyperintensity (cuffing), splenomegaly, ascites, lymphadenopathy, venous collaterals, and the configuration of intrahepatic biliary ducts were reviewed for their diagnostic significance by two observers in 13 female patients (mean age: 49 years) with PBC. Discordant readings of the observers were resolved at consensus. Results: When parenchymal lace-like fibrosis and periportal halo sign were seen together the sensitivity of T2-weighted MR images was 69%. In six cases periportal hyperintensity (cuffing) and periportal halo sign were seen together. Segmental hypertrophy was present in nine patients and hepatic surface irregularity due to regenerative nodules were present in 10 patients. Lymphadenopathy was seen in 10, splenomegaly was seen in 5, collateral vascular structures were seen in 2 and minimal perihepatic free fluid was seen in 2 patients. MRCP images revealed various mild irregularity in the intrahepatic bile ducts in 8 patients and focal narrowing at the common bile duct level in 1 patient. Conclusion: MRI and MRCP may support the clinical and laboratory findings of PBC even in the early stages of the disease. MRI can also be a choice of method for the recommended prolonged follow up.

  10. Primary biliary cirrhosis: Evaluation with T2-weighted MR imaging and MR cholangiopancreatography

    Energy Technology Data Exchange (ETDEWEB)

    Haliloglu, Nuray [Ankara University, Faculty of Medicine, Department of Radiology, Ibni Sina Hospital, 06100 Ankara (Turkey)], E-mail: nurayunsal2@hotmail.com; Erden, Ayse; Erden, Ilhan [Ankara University, Faculty of Medicine, Department of Radiology, Ibni Sina Hospital, 06100 Ankara (Turkey)

    2009-03-15

    Purpose: The aim of this retrospective study is to evaluate the role of T2-weighted MR imaging (MRI) and MR cholangiopancreatography (MRCP) findings in the diagnosis of primary biliary cirrhosis (PBC). Materials and methods: The following T2-weighted MRI and MRCP findings: segmental hepatic atrophy/hypertrophy, irregular liver surface, parenchymal lace-like fibrosis, rounded low signal intensity lesions centering portal vein branches (periportal halo sign), periportal hyperintensity (cuffing), splenomegaly, ascites, lymphadenopathy, venous collaterals, and the configuration of intrahepatic biliary ducts were reviewed for their diagnostic significance by two observers in 13 female patients (mean age: 49 years) with PBC. Discordant readings of the observers were resolved at consensus. Results: When parenchymal lace-like fibrosis and periportal halo sign were seen together the sensitivity of T2-weighted MR images was 69%. In six cases periportal hyperintensity (cuffing) and periportal halo sign were seen together. Segmental hypertrophy was present in nine patients and hepatic surface irregularity due to regenerative nodules were present in 10 patients. Lymphadenopathy was seen in 10, splenomegaly was seen in 5, collateral vascular structures were seen in 2 and minimal perihepatic free fluid was seen in 2 patients. MRCP images revealed various mild irregularity in the intrahepatic bile ducts in 8 patients and focal narrowing at the common bile duct level in 1 patient. Conclusion: MRI and MRCP may support the clinical and laboratory findings of PBC even in the early stages of the disease. MRI can also be a choice of method for the recommended prolonged follow up.

  11. The primary applications of Gd-DTPA as an oral negative gastrointestinal contrast agent for MRCP

    International Nuclear Information System (INIS)

    Chen Yanping; Zhang Xuelin; Cheng Guanxun; Chang Renmin; Zhang Yuzhong; Cang Peng; Xia Qiong

    2003-01-01

    Objective: Using oral Gd-DTPA as a negative contrast agent to null the bowel signal during MR cholangiopancreatography (MRCP) to improve the quality of MRCP. Methods: A phantom study was performed to select the optimal concentration of Gd-DTPA to be used as an oral negative contrast agent in MRCP. 15 patients suspected of biliary tract and pancreatic disease were performed with MRCP before and after using 250 ml oral contrast agents (1:5 diluted Gd-DTPA, 1.488 g/L). All MR images were acquired using a 1.5 T whole body MR scanner (Vision Plus, Siemens). MRCP was acquired using two-dimensional single slice fast spin-echo sequence and HASTE (half-fourier acquisition single-shot fast spin echo) sequence. Results: The phantom study showed that the dilution ratio 1:5 of Gd-DTPA oral contrast agent was best in decreasing the signal intensity both in T 2 WI (59.3%) and in HASTE sequence (82.45%). All the dilution ratio of Gd-DTPA oral contrast agent decreased the signal intensity up to 90% on single slice MRCP. In all the patients the high signal intensity from the stomach and intestinal fluid was completely suppressed. The depictions of common bile duct and pancreatic duct were markedly improved by the oral contrast agent (P<0.05). Conclusion: 1:5 diluted (1.488 g/L) oral MR contrast agent Gd-DTPA can be an effective and safe negative contrast agent in eliminating signal intensity of the gastrointestinal tract, thus improving the depiction of the biliary system in MRCP

  12. The value of adding conventional MR imaging to MR cholangiopancreatography in differentiation of benign and malignant causes of postoperative disorders

    International Nuclear Information System (INIS)

    Sun Changjin; Zhou Xiangping; Song Bin; Chen Xian; Liu Rongbo; Yan Zhihan; Xiong Yan

    2003-01-01

    Objective: To determine the value of conventional T 1 - and T 2 -weighted images and gadolinium-enhanced magnetic resonance (MR) images as a supplement to MR cholangiopancreatography (MRCP) in differentiation of benign from malignant causes of postoperative disorders in the biliary ductal system. Methods: Sixty-one patients with postoperative disorders in the biliary ductal system with proved causes underwent MRCP, conventional T 1 - and less heavily T 2 -weighted images, as well as gadolinium-enhanced images. Two radiologists independently reviewed MRCP images alone, MRCP plus nonenhanced T 1 - and T 2 -weighted images, and MRCP plus nonenhanced and gadolinium-enhanced images. The results of MR findings were compared with that of the surgical findings and the pathology. Results: For the diagnosis of postoperative disorders only with MRCP images, the sensitivity, specificity, and accuracy was 42.1%, 80.9% and 68.9% for radiologist 1 and 47.4%, 85.7%, and 73.8% for radiologist 2, respectively. When MRCP images were interpreted with T 1 - and T 2 -weighted images, the sensitivity, specificity, and accuracy was 78.9%, 92.9% and 88.5% for radiologist 1 and, 78.9%, 95.2%, and 90.2% for radiologist 2, respectively. When MRCP images were combined with both nonenhanced T 1 - and T 2 -weighted images and enhanced MR images, the sensitivity, specificity, and accuracy was 84.2%, 95.2% and 91.8% for radiologist 1 and 84.2%, 97.6%, and 93.4% for radiologist 2, respectively. There was no significant difference between the 2 readers (P>0.05). For differentiation of benign from malignant causes of postoperative disorders, the area under the receiver operating characteristic curve (Az) was significantly larger for MRCP images interpreted with T 1 - and T 2 weighted images (0.907 for reader 1, 0.920 for reader 2) than for MRCP images alone (0.682 reader 1, 0.714 for reader 2) (P 1 - and T 2 -weighted images did not significantly increase the accuracy (Az = 0.948 for reader 1, 0

  13. Pancreatic adenocarcinoma: combination of MR imaging, MR angiography and MR cholangiopancreatography for the diagnosis and assessment of resectability

    International Nuclear Information System (INIS)

    Catalano, C.; Pavone, P.; Laghi, A.; Panebianco, V.; Scipioni, A.; Fanelli, F.; Brillo, R.; Passariello, R.

    1998-01-01

    The purpose of this study was to determine the possibility of integrating MR cholangiopancreatography (MRCP) and MR angiography (MRA) to conventional MR images in the diagnosis and assessment of resectability of pancreatic adenocarcinoma. Twenty-three patients with pancreatic adenocarcinoma were prospectively examined with MR. Conventional MR images were acquired in all patients. Three-dimensional MRCP and MRA images were acquired in all patients with suspected biliary and vascular involvement. Acquisition time was less than 45 min in all cases. Images were independently evaluated by two radiologists, with final reading decided by consensus among readers. Diagnosis was confirmed with surgery in 16 patients and with percutaneous biopsy in 7. Concordance among readers was high with a kappa value of 0.83. Pancreatic adenocarcinoma was observed in all patients. Correct assessment of unresectability due to vascular involvement was found in 22 of 23 patients. Biliary obstruction was evident in 13 patients, involving the biliary and pancreatic ducts in 9 and the biliary ducts only in 4. Technical advances permit extensive use of MRI in the evaluation of abdominal pathologies. The combination of MR imaging, MRCP, and MRA can provide sufficient information for the diagnosis and assessment of resectability of pancreatic adenocarcinoma, which otherwise would require three different exams. (orig.)

  14. Value of selective MIP reconstructions of respiratory triggered 3D-TSE-MR cholangiography on a workstation versus standard MIP reconstructions and single-shot MRCP

    International Nuclear Information System (INIS)

    Schaible, R.; Textor, J.; Kreft, B.; Schild, H.; Neubrand, M.

    2001-01-01

    Comparison of anatomical visualisation and diagnostic value of selective MIP reconstructions of respiratory triggered 3D-TSE-MRCP versus standard MIP reconstructions and single-shot MRCP. Material and Methods: 50 patients with pancreaticobiliary disease were examined at 1.5 Tesla (ACS NT II, Philips Medical Systems) using a breath-hold single-shot (SS) and a respiratory triggered 3D-TSE-MRCP technique in 12 standard MIP projections. Additional selective MIP reconstructions with different slice thickness (2, 4, 10 cm) and projections were performed on a workstation. Visualization of the pancreaticobiliary system and the diagnostic value of the examinations were analysed. Results: Single-shot and 3D-TSE in standard projections showed comparable anatomical visualisation. On selective MIP reconstructions the biliary system (SS p [de

  15. Pancreatic changes in patients with primary sclerosing cholangitis: MR cholangiopancreatography and MRI findings

    International Nuclear Information System (INIS)

    Ozkavukcu, Esra; Erden, Ayse; Erden, Ilhan

    2009-01-01

    Purpose: To evaluate the possible pancreatic changes and their frequencies in patients with primary sclerosing cholangitis (PSC) on MR cholangiopancreatography (MRCP), and conventional abdominal MRI. Materials and Methods: Patient group consisted of 29 PSC (13 male, 16 female) cases, whereas cohort 1 consisted of 12 female patients with primary biliary cirrhosis, and cohort 2 consisted of 17 patients (6 male, 11 female) with non-immune chronic liver disease. Two radiologists retrospectively evaluated the MR examinations paying special attention to the pancreatic size (atrophy or enlargement), T1- and T2-signal intensity of the pancreas, focal pancreatic lesion, capsule-like rim, peripancreatic edema or fluid, fascial thickening, and pancreatic ducts (dilatation or narrowing). The results are expressed as percentages. Three groups were compared using Pearson chi-square test for each feature. However, only p-value for 'dilatation of the pancreatic duct' was determined, whereas p-value could not be calculated because of the insufficient number of subjects/sequences for the other features. Results: Twelve PSC patients (41.3%) had pancreatic abnormalities. The most common pancreatic changes in PSC patients were decreased T1-signal intensity (44%) and dilatation of the pancreatic duct (13.8%), respectively. Increased T2-signal intensity was also shown in 2 PSC patients (6.9%). Conclusion: Even PSC patients without any sign of pancreatitis, can show MR changes in the pancreatic parenchyma or the pancreatic duct. The etiologies of these changes, and whether they are unique to PSC, are still controversial. Histopathological studies bringing light to these pancreatic changes are needed.

  16. Usefulness of MR cholangiopancreatography after intravenous morphine administration

    International Nuclear Information System (INIS)

    Lee, So Jung; Ko, Ji Ho; Cho, Young Duk; Jung, Mi Hee; Yoon, Byung Chull

    2007-01-01

    We wanted to assess the usefulness of MRCP after intravenous morphine administration in the evaluation of the hepatopancreatic pancreatico-biliary ductal system. We studied 15 patients who were suspected of having disease of hepatopancreatic ductal system and they did not have any obstructive lesion on ultrasonography and/or CT. MRCP was acquired before and after morphine administration (0.04 mg/kg, intravenously). Three radiologists scored the quality of the images of the anatomic structures in the hepatopancreatic ductal system. We directly compared the quality of the images obtained with using the two methods and the improvement of the artifacts by pulsatile vascular compression. The MRCP images obtained after intravenous morphine administration were better than those obtained before morphine administration for visualizing the hepatopancreatic ductal system. On direct comparison, the MRCP images obtained after morphine administration were better in 12 cases, equivocal in two cases, and the images before morphine administration were better in only one case. In three patients, MRCP before morphine injection showed signal loss at the duct across the pulsatile hepatic artery. In two of three patients, MRCP after morphine injection showed no signal loss in this ductal area. MRCP after intravenous morphine administration enables physicians to see the hepatopancreatic ductal system significantly better and the artifacts caused by pulsation of the hepatic artery can be avoided

  17. Oral gadopentetate dimeglumine administration as a negative gastrointestinal contrast agent to improve image quality of MR cholangiopancreatography

    International Nuclear Information System (INIS)

    Chen Yi; Xu Yikai; Zhao Yuhui; Wang Guisheng

    2008-01-01

    Objective: To choose optimal concentration and volume of Gd-DTPA solution as a oral gastrointestinal negative contrast agent for MRCP. To evaluate the role of Gd-DTPA solution in improving image quality of MRCP. Methods: In vitro experiment: Gd-DTPA solution was made with different concentrations. T 1 WI, T 2 WI, two-dimensional single slice fast spin echo sequence and three-dimensional half-fourier acquisition single-shot fast spin echo sequence were performed to measure the signal intensity of these contrast agents respectively, so Gd-DTPA solution with the optimal concentration can be decided as oral negative gastrointestinal contrast agent on MRCP. Clinical study: The Gd-DTPA solution with optimal concentration and volume was regarded as an oral negative gastrointestinal contrast agent of MRCP. Twenty- four' patients were performed with MRCP before and after (5-10 minutes and 10-15 minutes) administration of oral negative gastrointestinal contrast agent and image quality was analyzed. Statistical analysis was performed using analysis of variance with SPSS 10.0. Results: When the concentration of Gd-DTPA solution was ≤0.01 mol/L, the contrast agent was hyperintense on T 1 WI. On T 2 WI, when the concentration was ≥0.015 mol/L, it was as hypointense as basic ground; On 2D FSE MRCP images, controls were hyperintense and the contrast agent with concentration ranging from 0.0025 mol/L to 0.03 mol/L was hypointense. On 3D HEAST MRCP image, controls were hyperintense and when the concentration of Gd-DTPA was ≥0.01 mol, the contrast agent was hypointense. The Gd-DTPA solution with the concentration of 0.01 mol/L and the volume of 100 ml was chosen as MRCP oral negative gastrointestinal contrast agent. On MRCP images after oral administration of the contrast agent, in 10-15 minutes, the average grade scores within 24 patients of the intrahepatic bile duct, the common hepatic bile duct, the gall bladder, the common bile duct and pancreatic duct (the average grade

  18. Assessment of the form and patency of the pancreatic duct by magnetic resonance cholangiopancreatography (MRCP)

    International Nuclear Information System (INIS)

    Kitamura, Masaya; Takahashi, Tuyoshi; Yoshida, Muneki; Shimada, Ken; Kakita, Akira; Isobe, Yoshinori

    1999-01-01

    There have been no reliable methods for the assessment of the patency of an end-to-side style pancreaticojejunal anastomosis in Whipple procedure. We evaluated the ability of MR-Cholangiopancreatography (MRCP) to assess the form and patency of the pancreatic duct in 181 patients. The pancreatic duct was displayed on MRCP in 70.9% of the patients. The domostrative rate of the pancreatic duct on MRCP and the PFD test were well correlated (p=0.031). Further, we assessed the patency of pancreaticojejunal anastomosis in Whipple procedure by MRCP following a secretin load. It was considered that the pancreatic duct to be patent when pancreatic excretion into the jejunum had increased and/or the ability to display the pancreatic duct had improved on MRCP following an i.v. load of secretin. A secretin-loading MRCP was suggested to be of much help in the assessment of the patency of pancreaticojejunostomy in patients undergoing Whipple procedure for a long-term follow up. (author)

  19. Assessment of the form and patency of the pancreatic duct by magnetic resonance cholangiopancreatography (MRCP)

    Energy Technology Data Exchange (ETDEWEB)

    Kitamura, Masaya; Takahashi, Tuyoshi; Yoshida, Muneki; Shimada, Ken; Kakita, Akira; Isobe, Yoshinori [Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Medicine

    1999-02-01

    There have been no reliable methods for the assessment of the patency of an end-to-side style pancreaticojejunal anastomosis in Whipple procedure. We evaluated the ability of MR-Cholangiopancreatography (MRCP) to assess the form and patency of the pancreatic duct in 181 patients. The pancreatic duct was displayed on MRCP in 70.9% of the patients. The domostrative rate of the pancreatic duct on MRCP and the PFD test were well correlated (p=0.031). Further, we assessed the patency of pancreaticojejunal anastomosis in Whipple procedure by MRCP following a secretin load. It was considered that the pancreatic duct to be patent when pancreatic excretion into the jejunum had increased and/or the ability to display the pancreatic duct had improved on MRCP following an i.v. load of secretin. A secretin-loading MRCP was suggested to be of much help in the assessment of the patency of pancreaticojejunostomy in patients undergoing Whipple procedure for a long-term follow up. (author)

  20. MR cholangiopancreatography: prospective comparison of a breath-hold 2D projection technique with diagnostic ERCP

    International Nuclear Information System (INIS)

    Lomas, D.J.; Bearcroft, P.W.P.; Gimson, A.E.

    1999-01-01

    The aim of this study was to compare prospectively a breath-hold projection magnetic resonance cholangiopancreatography (MRCP) technique with diagnostic endoscopic retrograde cholangiopancreatography (ERCP). Seventy-six patients with suspected strictures or choledocholithiasis were referred for MRCP and subsequent ERCP examination, which were performed within 4 h of each other. The MRCP technique was performed using fat-suppressed rapid acquisition with relaxation enhancement (RARE) projection images obtained in standardised planes with additional targeted projections as required by the supervising radiologist. Two radiologists (in consensus) assessed the MRCP results prospectively and independently for the presence of bile duct calculi, strictures, non-specific biliary dilatation and pancreatic duct dilatation, and recorded a single primary diagnosis. The ERCP was assessed prospectively and independently by a single endoscopist and used as a gold standard for comparison with MRCP. Diagnostic agreement was assessed by the Kappa statistic. The MRCP technique failed in two patients and ERCP in five. In the remaining 69 referrals ERCP demonstrated normal findings in 23 cases, strictures in 19 cases, choledocholithiasis in 9 cases, non-specific biliary dilatation in 14 cases and chronic pancreatitis in 4 cases. The MRCP technique correctly demonstrated 22 of 23 normal cases, 19 strictures with one false positive (sensitivity 100 %, specificity 98 %), all 9 cases of choledocholithiasis with two false positives (sensitivity 100 %, specificity 97 %), 12 of 14 cases of non-specific biliary dilatation and only 1 of 4 cases of chronic pancreatitis. There was overall good agreement for diagnosis based on a kappa value of 0.88. Breath-hold projection MRCP can provide non-invasively comparable diagnostic information to diagnostic ERCP for suspected choledocholithiasis and biliary strictures and may allow more selective use of therapeutic ERCP. (orig.)

  1. The role of MR cholangiopancreatography in acute abdominal pain (a case study)

    International Nuclear Information System (INIS)

    Obradovic, G.

    2000-01-01

    Rapid technological advances have resulted in improved Magnetic Resonance Imaging (MRI) of the abdomen. In particular, the development of single breath hold sequences have led to a resurgence in imaging of the binary tree and pancreatic duct. For this reason, Magnetic Resonance Cholangiopancreatography (MRCP) is recognised as a valuable tool which is safe, fast and noninvasive. This case study demonstrates that MRCP could identify the intrahepatic duct obstruction adequately, so that the appropriate course of management could be readily instigated. In addition, the excellent quality of MR imaging will lead to an increase in referrals for MRCP if the modality is available and there are no patient contra-indications. Copyright (1999) Australian Institute of Radiography

  2. MRCP. Magnetic resonance cholangiopancreatography; MRCP. Magnetresonanzcholangiopankreatografie

    Energy Technology Data Exchange (ETDEWEB)

    Kinner, Sonja [Wisconsin-Madison Univ., Madison, WI (United States). Dept. of Radiology; Lauenstein, Thomas [Evangelisches Krankenhaus Duesseldorf (Germany). Radiologie

    2016-06-15

    Magnetic resonance cholangiopancreatography (MRCP) is a special MR technique to display and analyze the biliary tract and pancreatic ducts. MRCP sequences are equivalent to endoscopic retrograde cholangiopancreatography (ERCP) for diagnostic purposes due to technical developments of the classical T2 weighted MRCP sequences and the availability of contrast enhanced T1 weighted sequences. Therefore, MRCP plays a fundamental role in the diagnoses of hepatobliary and pancreatic diseases, which are presented in this review article as are technical details of sequence acquisitions and the underlying anatomy.

  3. Imaging features of portal biliopathy: Frequency of involvement patterns with emphasis on MRCP

    Energy Technology Data Exchange (ETDEWEB)

    Ozkavukcu, Esra [Ankara University School of Medicine, Department of Radiology (Turkey)], E-mail: eozkavukcu@gmail.com; Erden, Ayse; Erden, Ilhan [Ankara University School of Medicine, Department of Radiology (Turkey)

    2009-07-15

    Purpose: To investigate the imaging features of portal biliopathy with emphasis on MR cholangiopancreatography (MRCP). The ancillary vascular findings of portal biliopathy were also evaluated by accompanying MR portography, dynamic contrast-enhanced (CE) CT, and dynamic CE MRI studies. Materials and methods: Sixteen patients with portal cavernoma were included in the study. Patients had undergone MRCP (n = 16) studies accompanied by MR portography (n = 13), dynamic CE CT (n = 3) or dynamic CE MRI (n = 2) of the liver. Two patients had undergone both dynamic CE CT and dynamic CE MRI. Two radiologists evaluated all the examinations together, retrospectively. MRCP images were analyzed for the presence of biliary stenosis, upstream (prestenotic) dilatation, wavy appearance of the bile ducts, angulation of the common bile duct (CBD), and choledocholithiasis. MR portography, dynamic CE CT and dynamic CE MRI studies were evaluated for the existence of portal cavernomas, and the presence of gall bladder/choledochal varices. Results: All patients had signs of portal biliopathy on MRCP. Frequencies of the biliary findings on MRCP were as follows: biliary stenosis, 93.7%; upstream dilatation, 68.7%; wavy appearance of the biliary tree, 87.5%; angulation of the CBD, 75%. None of the patients had choledocholithiasis. Frequencies of the ancillary vascular findings detected on CE studies were as follows: gall bladder varices, 100%, choledochal varices, 93.7%. Conclusion: MRCP features of portal biliopathy in order to their frequencies were as follows: biliary stenosis, wavy appearance of the bile ducts, angulation of the CBD, and upstream dilatation of the bile ducts.

  4. Quality rating of MR-cholangiopancreatography with oral application of iron oxide particles

    International Nuclear Information System (INIS)

    Lorenzen, M.; Wedegaertner, U.; Fiehler, J.; Adam, G.

    2003-01-01

    Purpose: To compare image quality in magnetic resonance cholangiopancreatography (MRCP) performed with and without oral application of Loesferron trademark (ferrous gluconate, Lilly Pharma, Hamburg). Materials and Methods: A prospective study compares MRCPs performed on 52 patients with a 1.5 T clinical whole body scanner using a standard body coil. After randomization, patients ingested either 0.5 l of Loeseferron trademark (n=27, group 1) or no oral contrast agent (n=25, group 2) prior to the examination. 7 RARE (40 to 20 ) sequences were obtained, followed by selected 3 mm HASTE (T 2 -weighted with fat suppression) sequences. After blinding, image quality was rated by two radiologists using a scale of 1 (not discernible) to 5 (very well discernible). The following sections of the biliary ductal system were evaluated: left and right hepatic duct, extrahepatic bile duct and intrapancreatic bile duct. The pancreatic duct was evaluated by its location: head, body and tail of the pancreas. A Wilcoxon-Mann-Whitney test was used to determine significant differences (p trademark was well tolerated by all patients, and all sequences could be acquired and evaluated in all 52 patients. For the different sections of the biliary system, the mean ratings with and without Loesferron trademark were, respectively, 3.28 and 3.36 for the left hepatic duct, 3.26 and 3.33 for the right hepatic duct, 3.46 and 4.0 for the extrahepatic bile duct, and 2.8 and 3.48 for the intrapancreatic bile duct. The corresponding ratings for the pancreatic duct were 2.8 and 3.24 for the pancreatic head, 2.84 and 3.38 for the pancreatic body, and 2.68 and 3.22 for the pancreatic tail. The differences with and without contrast agent were not statistically significant. Interobserver variability was between 0.37 for the pancreatic duct in the tail of the pancreas and 0.66 for the right hepatic duct. Conclusion: Despite the trend toward a better rating of the image quality for all sections of the

  5. MR imaging and MR cholangiopancreatography in the preoperative evaluation of hilar cholangiocarcinoma: correlation with surgical and pathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Masselli, Gabriele; Gualdi, Gianfranco [Umberto I Hospital-La Sapienza University Rome, Department of Radiology, Rome (Italy); Manfredi, Riccardo [University of Verona, Department of Radiology, Verona (Italy); Vecchioli, Amorino [A. Gemelli Hospital-University of Sacred Heart, Department of Radiology, Rome (Italy)

    2008-10-15

    The primary aim was to evaluate delayed contrast-enhanced MRI in depicting perineural spread of hilar cholangiocarcinoma (CCC) and consequently to determine the capability of MRI/MRCP for staging CCC. Fifteen patients that underwent MRI/MRCP and surgical treatment were retrospectively included. Two radiologists evaluated MR images to assess delayed periductal enhancement, extent of bile duct stenosis, liver parenchymal and vascular involvement and presence of liver atrophy. An agreement between delayed enhancement of the bile duct walls and perineural neoplastic spread showed a very good correlation factor (0.93). The overall accuracy in detecting biliary neoplastic invasion was higher for delayed T1-weighted images (93.3%) than for the MRCP images (80%), and T1-delayed image increased the MR accuracy in assessing the neoplastic resectability (p < 0.05). MRI correctly predicted vascular involvement in 73% and liver involvement in 80% of the cases. The number of overall correctly assessed patients with regard to resectability was 11 true positive, 1 false positive and 3 true negative. The combination of MRI/MRCP is a reliable diagnostic method for staging hilar cholangiocarcinomas. Delayed periductal enhancement is accurate in the evaluation of neoplastic perineural spread, and it can improve diagnostic accuracy to identify resectable and unresectable tumours. (orig.)

  6. The Impact of Gd-Eob-Dtpa-Enhanced MR Cholangiography in Biliary Diseases: Comparison with T2-Weighted MR Cholangiopancreatography

    Directory of Open Access Journals (Sweden)

    Evrim Özmen

    2016-06-01

    Full Text Available Background: Contrast enhanced magnetic resonance cholangiography is a novel technique and promising method in demonstrating biliary tree anatomy and evaluating biliary disorders. However, to date, there are a limited number of studies that have focused on the impact of this technique. Aims: We aimed to evaluate the additional role of contrast enhanced MR cholangiography (MRC and compare contrast enhanced MRC with T2-weighted (w magnetic resonance cholangiopancreatography (MRCP in the diagnosis of biliary disorders. Study Design: Diagnostic accuracy study. Methods: The T2w-MRCP and contrast enhanced MRC sequences of 31 patients whose gold standard test results were available were scored visually for the existence of pathological findings with regard to any of the biliary diseases. Gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA was used as the contrast agent. The correlation values were determined according to the statistical analysis made from those scores and the sensitivity, specificity and accuracy values of each sequence were detected as well. Results: We detected that the correlation values with gold standard methods of contrast enhanced MRC sequences were significantly higher than the ones of T2w-MRCP sequences. The correlation ratios of T2w-MRCP sequences were between 26 and 34%, while those for contrast enhanced MRC sequences were between 81 and 83% for the first reader and the correlation ratios of T2w-MRCP sequences were between 10 and 61%, whereas those of contrast enhanced MRC were between 79 and 81% for the second reader The mean sensitivity, specificity and accuracy values of T2w-MRCP sequences were 14.3-42.5%, 85-89.2% and 59.3-72.5%, respectively, while the mean sensitivity, specificity and accuracy values of contrast enhanced MRC sequences were 100%, 86.7% and 93.2-93.3%, respectively. Conclusion: We suggest that obtaining of contrast enhanced MRC sequences in addition to the T2w-MRCP can be useful in

  7. Automatic gallbladder segmentation using combined 2D and 3D shape features to perform volumetric analysis in native and secretin-enhanced MRCP sequences.

    Science.gov (United States)

    Gloger, Oliver; Bülow, Robin; Tönnies, Klaus; Völzke, Henry

    2017-11-24

    We aimed to develop the first fully automated 3D gallbladder segmentation approach to perform volumetric analysis in volume data of magnetic resonance (MR) cholangiopancreatography (MRCP) sequences. Volumetric gallbladder analysis is performed for non-contrast-enhanced and secretin-enhanced MRCP sequences. Native and secretin-enhanced MRCP volume data were produced with a 1.5-T MR system. Images of coronal maximum intensity projections (MIP) are used to automatically compute 2D characteristic shape features of the gallbladder in the MIP images. A gallbladder shape space is generated to derive 3D gallbladder shape features, which are then combined with 2D gallbladder shape features in a support vector machine approach to detect gallbladder regions in MRCP volume data. A region-based level set approach is used for fine segmentation. Volumetric analysis is performed for both sequences to calculate gallbladder volume differences between both sequences. The approach presented achieves segmentation results with mean Dice coefficients of 0.917 in non-contrast-enhanced sequences and 0.904 in secretin-enhanced sequences. This is the first approach developed to detect and segment gallbladders in MR-based volume data automatically in both sequences. It can be used to perform gallbladder volume determination in epidemiological studies and to detect abnormal gallbladder volumes or shapes. The positive volume differences between both sequences may indicate the quantity of the pancreatobiliary reflux.

  8. Clinical evaluation of further-developed MRCP sequences in comparison with standard MRCP sequences

    International Nuclear Information System (INIS)

    Hundt, W.; Scheidler, J.; Reiser, M.; Petsch, R.

    2002-01-01

    The purpose of this study was the comparison of technically improved single-shot magnetic resonance cholangiopancreatography (MRCP) sequences with standard single-shot rapid acquisition with relaxation enhancement (RARE) and half-Fourier acquired single-shot turbo spin-echo (HASTE) sequences in evaluating the normal and abnormal biliary duct system. The bile duct system of 45 patients was prospectively investigated on a 1.5-T MRI system. The investigation was performed with RARE and HASTE MR cholangiography sequences with standard and high spatial resolutions, and with a delayed-echo half-Fourier RARE (HASTE) sequence. Findings of the improved MRCP sequences were compared with the standard MRCP sequences. The level of confidence in assessing the diagnosis was divided into five groups. The Wilcoxon signed-rank test at a level of p<0.05 was applied. In 15 patients no pathology was found. The MRCP showed stenoses of the bile duct system in 10 patients and choledocholithiasis and cholecystolithiasis in 16 patients. In 12 patients a dilatation of the bile duct system was found. Comparison of the low- and high spatial resolution sequences and the short and long TE times of the half-Fourier RARE (HASTE) sequence revealed no statistically significant differences regarding accuracy of the examination. The diagnostic confidence level in assessing normal or pathological findings for the high-resolution RARE and half-Fourier RARE (HASTE) was significantly better than for the standard sequences. For the delayed-echo half-Fourier RARE (HASTE) sequence no statistically significant difference was seen. The high-resolution RARE and half-Fourier RARE (HASTE) sequences had a higher confidence level, but there was no significant difference in diagnosis in terms of detection and assessment of pathological changes in the biliary duct system compared with standard sequences. (orig.)

  9. Differential diagnosis of benign and malignant intraductal papillary mucinous tumors of the pancreas: MR cholangiopancreatography and MR angiography

    International Nuclear Information System (INIS)

    Choi, Byung Se; Kim, Tae Kyoung; Kim, Ah Young; Kim, Kyoung Won; Park, Sung Won; Kim, Pyo Nyun; Ha, Kyun Kwon; Lee, Moon Gyu; Kim, Song Cheol

    2003-01-01

    To compare the usefulness of magnetic resonance cholangiopancreatography (MRCP) and MR angiography (MRA) in differentiating malignant from benign intraductal papillary mucinous tumors of the pancreas (IPMTs), and to determine the findings which suggest malignancy. During a 6-year period, 46 patients with IPMT underwent MRCP. Morphologically, tumor type was classified as main duct, branch duct, or combined. The diameter of the main pancreatic duct (MPD), the extent of the dilated MPD, and the location and size of the cystic lesion, septum, and communicating channel were assessed. For all types of IPMTs, enhanced mural nodules and portal vein narrowing were evaluated at MRA. Combined-type IPMTs were more frequently malignant (78%) than benign (42%) (p<0.05). Compared with benign lesions, malignant lesions were larger, and the caliber of the communicating channel was also larger (p < 0.05). Their dilated MPD was more extensive and of greater diameter (p<0.05), and the presence of mural nodules was more frequent (p<0.001). Combined MRCP and MRA might be useful for the differential diagnosis of malignant and benign IPMTs of the pancreas

  10. MRCP in the evaluation of pancreaticobiliary disease in children

    Energy Technology Data Exchange (ETDEWEB)

    Arcement, C.M.; Meza, M.P.; Arumanla, S.; Towbin, R.B. [Children' s Hospital of Pittsburgh, Dept. of Radiology, Pittsburgh, PA (United States)

    2001-02-01

    Background. Radiologic assessment of pancreaticobiliary ductal disease (PBDD) in children currently consists of physiologic tests (radionuclide examinations) or invasive anatomic studies (ERCP and PTC). An accurate noninvasive and reproducible examination that can direct the subsequent need for more invasive studies would be helpful in this patient group. Objective. To determine the effectiveness of MRCP as a screening tool for PBBD in the pediatric population. Materials and methods. Over the last year, 33 patients ranging from 7 months to 20 years of age were prospectively evaluated with MRCP on a 1.5 T magnet. One patient was examined twice, several months apart. Thirteen patients had liver transplants. Coronal SPGR and heavily T-2W FSE cross-sectional images were obtained. Standard and oblique 2- to 6-cm-thick slab SSFSE (single-shot fast spin echo) acquisition and 3D MIP reconstruction of 2D FSE images were obtained in the planes of the CBD and pancreatic duct. Nine studies were performed with the patient under sedation with chloral hydrate or nembutal and fentanyl with quiet respiration, and the non-sedated patients were assessed with single breath hold or quiet respiration. Three patients received secretin. MRCP results were correlated with ERCP (9), PTC (7), liver biopsy (13), clinical information (6), surgery (3), and autopsy (2). Results. All 34 studies performed were considered diagnostic. Periportal fluid, proximal bowel fluid, and gallbladder distention did not significantly diminish the diagnostic information in any cases. Motion artifact did not cause serious degradation in image quality. MRCP depicted abnormalities including stones, stricture, intraductal tumor, and extrinsic compression, all of which were confirmed at ERCP, PTC (two unsuccessful in patients with non-dilated ducts by MRCP), surgery, liver biopsy, and autopsy. There were no false-negative examinations. Normal pancreatic studies performed to exclude pancreas divisum were followed

  11. MRCP in the evaluation of pancreaticobiliary disease in children

    International Nuclear Information System (INIS)

    Arcement, C.M.; Meza, M.P.; Arumanla, S.; Towbin, R.B.

    2001-01-01

    Background. Radiologic assessment of pancreaticobiliary ductal disease (PBDD) in children currently consists of physiologic tests (radionuclide examinations) or invasive anatomic studies (ERCP and PTC). An accurate noninvasive and reproducible examination that can direct the subsequent need for more invasive studies would be helpful in this patient group. Objective. To determine the effectiveness of MRCP as a screening tool for PBBD in the pediatric population. Materials and methods. Over the last year, 33 patients ranging from 7 months to 20 years of age were prospectively evaluated with MRCP on a 1.5 T magnet. One patient was examined twice, several months apart. Thirteen patients had liver transplants. Coronal SPGR and heavily T-2W FSE cross-sectional images were obtained. Standard and oblique 2- to 6-cm-thick slab SSFSE (single-shot fast spin echo) acquisition and 3D MIP reconstruction of 2D FSE images were obtained in the planes of the CBD and pancreatic duct. Nine studies were performed with the patient under sedation with chloral hydrate or nembutal and fentanyl with quiet respiration, and the non-sedated patients were assessed with single breath hold or quiet respiration. Three patients received secretin. MRCP results were correlated with ERCP (9), PTC (7), liver biopsy (13), clinical information (6), surgery (3), and autopsy (2). Results. All 34 studies performed were considered diagnostic. Periportal fluid, proximal bowel fluid, and gallbladder distention did not significantly diminish the diagnostic information in any cases. Motion artifact did not cause serious degradation in image quality. MRCP depicted abnormalities including stones, stricture, intraductal tumor, and extrinsic compression, all of which were confirmed at ERCP, PTC (two unsuccessful in patients with non-dilated ducts by MRCP), surgery, liver biopsy, and autopsy. There were no false-negative examinations. Normal pancreatic studies performed to exclude pancreas divisum were followed

  12. Diagnostic accuracy of MRCP in choledocholithiasis

    International Nuclear Information System (INIS)

    Guarise, Alessandro; Mainardi, Paride; Baltieri, Susanna; Faccioli, Niccolo'

    2005-01-01

    Purpose: To evaluate the accuracy of MRCP in diagnosing choledocholithiasis considering Endoscopic Retrograde Cholangiopancreatography (ERCP) as the gold standard. To compare the results achieved during the first two years of use (1999-2000) of Magnetic Resonance Cholangiopancreatography (MRCP) in patients with suspected choledocholithiasis with those achieved during the following two years (2001-2002) in order to establish the repeatability and objectivity of MRCP results. Materials and methods: One hundred and seventy consecutive patients underwent MRCP followed by ERCP within 72 h. In 22/170 (13%) patients ERCP was unsuccessful for different reasons. MRCP was performed using a 1.5 T magnet with both multi-slice HASTE sequences and thick-slice projection technique. Choledocholithiasis was diagnosed in the presence of signal void images in the dependent portion of the duct surrounded by hyperintense bile and detected at least in two projections. The MRCP results, read independently from the ERCP results, were compared in two different and subsequent periods. Results: ERCP confirmed choledocholithiasis in 87 patients. In these cases the results of MRCP were the following: 78 true positives, 53 true negatives, 7 false positives, and 9 false negatives. The sensitivity, specificity and accuracy were 90%, 88% and 89%, respectively. After the exclusion of stones with diameters smaller than 6 mm, the sensitivity, specificity and accuracy were 100%, 99% and 99%, respectively. MRCP accuracy was related to the size of the stones. There was no significant statistical difference between the results obtained in the first two-year period and those obtained in the second period. Conclusions: MRCP i sufficiently accurate to replace ERCP in patients with suspected choledocholithiasis. The results are related to the size of stones. The use of well-defined radiological signs allows good diagnostic accuracy independent of the learning curve [it

  13. Non-invasive quantification of pancreatic exocrine function using secretin-stimulated MRCP

    International Nuclear Information System (INIS)

    Punwani, S.; Gillams, A.R.; Lees, W.R.

    2003-01-01

    Our objective was to quantify water volume using magnetic resonance cholangiopancreatography (MRCP) sequences and apply this to secretin-stimulated studies with the aim of quantifying pancreatic exocrine function. A commercially available single-shot MRCP sequence was used in conjunction with a body phased-array coil and a 1.5-T MR system. Signal intensity was measured in samples of water, pancreatic, duodenal juice, and secretin-stimulated pancreatic juice. A water phantom was made and MR calculated volumes compared with known water volumes within the phantom. Changes in small intestinal volume in response to secretin were measured in a group of 11 patients with no evidence of pancreatic disease. Changes in water volume were plotted over time. The pancreatic duct diameter before and after secretin was noted and filling defects were sought. All patients also underwent an axial breath-hold T1-weighted gradient-echo sequence and the pancreatic parenchyma was evaluated for size and signal intensity. There was no difference in the signal intensity of the different juice samples. There was excellent correlation between known and calculated MRCP volumes (χ 2 =0.99). All patients demonstrated normal duct morphology on MRCP and normal pancreatic parenchyma on T1-weighted imaging. The mean flow rate in the patient population was 8.1±2.5 ml/s over a median of 7 min (range 5-9 min). The MRCP sequence can be used to measure water volume. Sequential MRCP measurements following secretin permitted calculation of volume change and flow rate. This should prove useful as an indicator of pancreatic exocrine function. (orig.)

  14. Quality rating of MR-cholangiopancreatography with oral application of iron oxide particles; Wertigkeit der MR-Cholangiopankreatikographie nach Gabe eines oralen eisenhaltigen Kontrastmittels

    Energy Technology Data Exchange (ETDEWEB)

    Lorenzen, M.; Wedegaertner, U.; Fiehler, J.; Adam, G. [Universitaetsklinikum Hamburg, Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie (Germany)

    2003-07-01

    Purpose: To compare image quality in magnetic resonance cholangiopancreatography (MRCP) performed with and without oral application of Loesferron {sup trademark} (ferrous gluconate, Lilly Pharma, Hamburg). Materials and Methods: A prospective study compares MRCPs performed on 52 patients with a 1.5 T clinical whole body scanner using a standard body coil. After randomization, patients ingested either 0.5 l of Loeseferron {sup trademark} (n=27, group 1) or no oral contrast agent (n=25, group 2) prior to the examination. 7 RARE (40 to 20 ) sequences were obtained, followed by selected 3 mm HASTE (T{sub 2}-weighted with fat suppression) sequences. After blinding, image quality was rated by two radiologists using a scale of 1 (not discernible) to 5 (very well discernible). The following sections of the biliary ductal system were evaluated: left and right hepatic duct, extrahepatic bile duct and intrapancreatic bile duct. The pancreatic duct was evaluated by its location: head, body and tail of the pancreas. A Wilcoxon-Mann-Whitney test was used to determine significant differences (p<0.05) between sampled ductal segments. Correction for multiple testing was applied. Results: The oral application of Loeseferron {sup trademark} was well tolerated by all patients, and all sequences could be acquired and evaluated in all 52 patients. For the different sections of the biliary system, the mean ratings with and without Loesferron {sup trademark} were, respectively, 3.28 and 3.36 for the left hepatic duct, 3.26 and 3.33 for the right hepatic duct, 3.46 and 4.0 for the extrahepatic bile duct, and 2.8 and 3.48 for the intrapancreatic bile duct. The corresponding ratings for the pancreatic duct were 2.8 and 3.24 for the pancreatic head, 2.84 and 3.38 for the pancreatic body, and 2.68 and 3.22 for the pancreatic tail. The differences with and without contrast agent were not statistically significant. Interobserver variability was between 0.37 for the pancreatic duct in the tail of

  15. CT vs. MRCP in choledocholithiasis jaundice.

    Science.gov (United States)

    Petrescu, I; Bratu, A M; Petrescu, S; Popa, B V; Cristian, D; Burcos, T

    2015-01-01

    Obstructive jaundice can raise problems to diagnostic imaging. The radiologist must choose the most appropriate examination that delivers the most important diagnostic information because the differences between a lithiasic obstruction and a tumoral one are vital. This information helps the surgeon speed up the process of decision-making, because the treatment may be very different in relation to the nature of the obstruction. This study tries to demonstrate the diagnostic accuracy of computed tomography (CT) and magnetic resonance cholangiopancreatography (MRCP) in detecting the obstacle in the common bile duct (CBD) and the possibility of establishing the lithiasic nature of the obstruction. A retrospective analysis was analyzed during an interval of 18 months that included jaundice patients admitted in the General Surgery Department of "Coltea" Clinical Hospital. They were examined by CT scanning and by MRCP, being suspected of choledocholithiasis. 63 patients were included in the study, 34 females and 29 males. 33 CT scans and 30 MRCP exams were performed. CT scan is useful in detecting residual or iterative choledocholithiasis in patients after cholecystectomy, contrast enhanced CT (CECT), being able to differentiate between lithiasic and non-lithiasic obstruction. MRCP delivers important anatomic details of the biliary tree; it is superior to CT in diagnosing the hepatocholedochal lithiasis; MRCP tends to replace endoscopic retrograde cholangiopancreatography (ERCP)--the diagnostic "gold standard" reducing the number of unnecessary invasive diagnostic procedures.

  16. Diagnostic value of high strength MRCP in the obstructive jaundice

    International Nuclear Information System (INIS)

    Yang Yang; Dong Yuhai; Yin Jie; Lv Guoyi

    2007-01-01

    Objective: To evaluate the diagnostic value of high strength MRCP in patients with obstructive jaundice. Methods: Routine MRI and MRCP examination on 161 patients with obstructive jaundice were carded out with 1.5T Siemens super-conductive magnetic resonance machine. Of them, 103 cases were benign lesions and 58 were malignant after surgical and ERCP pathological confirmation. Results: The diagnostic accuracy of MRCP was 100%, with the qualitative diagnostic accuracy at 90.2%. Conclusion: MRCP was the best method in diagnosing patients with obstructive jaundice, the concerned performances of MRCP could provide the dependable basis for surgical operation project. (authors)

  17. Comparison between magnetic resonance cholangiopancreatography (MRCP) and endoscopic retrograde cholangiopancreatography (ERCP); Comparacion entre calongiografia por resonancia magnetica (CPRM) y colangiografia retrograda endoscopia (CPRE)

    Energy Technology Data Exchange (ETDEWEB)

    Pulpeiro, J. R.; Armesto, V. [Clinica Nosa Senora dos Ollos Grandes. Lugo (Spain); Lopez-Roses, L.; Lancho, A.; Gonzalez, A. [Hospital Xeral. Lugo (Spain)

    2000-07-01

    To assess the correlation between magnetic resonance cholangiopancreatography (MRCP) and endoscopic retrograde cholangiopancreatography (ERCP). The authors carried out a prospective study of 71 patients suspected of having biliary diseases. MRCP was performed, followed by ERCP.MRCP was done with a 1.5-T system using hypergradients, abdominal phase array coil and single-shot fast spin-echo (SSFSE) sequences with maximum signal intensity in T2-weighted images. This sequence only provides images of the fluids, similar to those obtained with ERCP. The results of ERCP were employed as a reference standard. Thirty patients were found to have stenosis (19 malignant and 11 benign). 25 had choledocholithiasis and 16 showed no abnormal findings. The correlation was complete in patients with stenosis. MRCP detected 23 cases of choledocholithiasis (ERCP was normal in the remaining two patients, but calculi were discovered on shpincterotomy). MRCP confirmed the normal condition of the bile duct in 12 of the 16 patients free of biliary disease (2 patients in whom ERCP had been normal had been diagnosed as having bile duct dilatation due to choledocholithiasis 24 hours and 10 days earlier, respectively, and two cases of presented ectasia due to fibrosis of the sphincter of Oddi showed good emptying during ERCP). MRCP using SSFSE is highly correlated with ERCP, which should be reserved for cases in which the diagnosis is in doubt or endoscopic management is necessary. (Author) 25 refs.

  18. Comparison of 2D and 3D sequences for MRCP. Clinical value of the different techniques; Vergleich von 2D- und 3D-Sequenzen fuer die MRCP. Klinischer Stellenwert der einzelnen Techniken

    Energy Technology Data Exchange (ETDEWEB)

    Wallnoefer, A.M.; Herrmann, K.A.; Zech, C.J.; Gourtsoyianni, S.; Reiser, M.F.; Schoenberg, S.O. [Klinikum Grosshadern der Ludwig-Maximilian-Universitaet Muenchen (Germany). Institut fuer Klinische Radiologie; Beuers, U. [Klinikum Grosshadern der Ludwig-Maximilian-Universitaet Muenchen (Germany). Klinik fuer Innere Medizin II

    2005-11-01

    Magnetic resonance cholangio-pancreaticograpy (MRCP) is a non-invasive imaging modality of the pancreatico-biliary system which plays an increasingly important role in the clinical and diagnostic workup of patients with biliary or pancreatic diseases. The present review is designed to give an overview of the currently available and appropriate sequences, their technical background, as well as new developments and their relevance to the various clinical issues and challenges. The impact of the latest technical innovations, such as integrated parallel imaging techniques and navigator-based respiratory triggering, on the diagnostic capacities of MRCP is discussed. In this context, the individual value of RARE, T2w single shot turbo/fast spin echo (SSFSE) and the recently introduced 3D T2w turbo/fast spin echo sequences (T2w 3D-T/FSE) is reviewed. RARE imaging may be preferred in severely ill patients with limitations in cooperation, SSFSE is particularly effective in differentiating benign and malignant stenosis, and 3D-FSE offers additional advantages in the detection of small biliary concrements. (orig.) [German] Die Magnetresonanzcholangiopankreatikographie (MRCP) ist eine nichtinvasive Untersuchungsmethode des pankreatikobiliaeren Systems, die heute einen festen Platz in der klinischen Diagnostik eingenommen hat. Die vorliegende Arbeit gibt einen Ueberblick ueber die derzeit gaengigen Sequenzen, ihre technischen Grundlagen sowie ihre jeweilige Bedeutung in den verschiedenen klinischen Einsatzgebieten und Fragestellungen. Darueber hinaus werden die Bedeutung der parallelen Bildgebung, der navigatorbasierten Atemtriggerung und der neu eingefuehrten dreidimensionalen Sequenzen fuer die MRCP sowie ihre moeglichen Einsatzgebiete behandelt. Fuer die MRCP haben die 3 gaengigen Sequenzen, die SS-RARE-Sequenz, die T2w-single-shot-fast-spin-echo- (SSFSE) und die 3D-FSE-Sequenz spezifische Vor- und Nachteile. Die SS-RARE-Sequenz ist aufgrund der sehr kurzen Messzeit bei

  19. Evaluation of dynamic MRCP after secretin stimulation for biliopancreatic diseases

    International Nuclear Information System (INIS)

    Ohhigashi, Seiji; Nishio, Takeki; Watanabe, Fumihiko; Haradome, Hiroki; Doi, Osamu

    2000-01-01

    Both pancreaticobiliary maljunction and pancreatogastrostomy after pancreatoduodenectomy were analyzed to assess the utility of dynamic MRCP after secretin stimulation. Dynamic MRCP obtained every 60 seconds for 15 minutes after secretin administration revealed the bile and pancreatic fluid kinetics. Calculating the intensity value from the MR images allowed objective estimation of the bile and pancreatic fluid kinetics. Thus, this study demonstrated that dynamic MRCP after secretin stimulation was significantly useful in evaluating not only the morphologic features in pancreaticobiliary maljunction but also pancreatic exocrine function after resection of the pancreas. (author)

  20. [Comparison of 2D and 3D sequences for MRCP. Clinical value of the different techniques].

    Science.gov (United States)

    Wallnoefer, A M; Herrmann, K A; Beuers, U; Zech, C J; Gourtsoyianni, S; Reiser, M F; Schoenberg, S O

    2005-11-01

    Magnetic resonance cholangio-pancreaticograpy (MRCP) is a non-invasive imaging modality of the pancreatico-biliary system which plays an increasingly important role in the clinical and diagnostic workup of patients with biliary or pancreatic diseases. The present review is designed to give an overview of the currently available and appropriate sequences, their technical background, as well as new developments and their relevance to the various clinical issues and challenges. The impact of the latest technical innovations, such as integrated parallel imaging techniques and navigator-based respiratory triggering, on the diagnostic capacities of MRCP is discussed. In this context, the individual value of RARE, T2w single shot turbo/fast spin echo (SSFSE) and the recently introduced 3D T2w turbo/fast spin echo sequences (T2w 3D-T/FSE) is reviewed. RARE imaging may be preferred in severely ill patients with limitations in cooperation, SSFSE is particularly effective in differentiating benign and malignant stenosis, and 3D-FSE offers additional advantages in the detection of small biliary concrements.

  1. Utility of MRCP in clinical decision making of suspected choledocholithiasis: An institutional analysis and literature review.

    Science.gov (United States)

    Badger, Wesley R; Borgert, Andrew J; Kallies, Kara J; Kothari, Shanu N

    2017-08-01

    The ideal treatment algorithm for suspected choledocholithiasis is not yet well defined. Imaging options include magnetic resonance cholangiopancreatography (MRCP), endoscopic retrograde cholangiopancreatography (ERCP), and intraoperative cholangiogram (IOC). MRCP is diagnostic, while the other two modalities can also be therapeutic. Each of these modalities for diagnosis and treatment carries its own set of risks, benefits, and institutional costs. We hypothesized that there would be a significant difference between the biochemical profiles and characteristics of patients who undergo ERCP vs. MRCP vs. operative intervention as the initial choice of treatment/imaging modality. We performed a retrospective review of the electronic medical records for all patients with a coded diagnosis of choledocholithiasis from 2011 to 2014. The initial diagnostic modality was assessed for each hospital encounter. The statistical characteristics of MRCP as compared to fluoroscopic imaging of the biliary tree (ERCP, IOC) were analyzed. Overall, 527 hospital encounters were identified. Initial intervention included ERCP in 63%, MRCP in 12%, and cholecystectomy in 25% of patients. Patients undergoing cholecystectomy first, compared to MRCP or ERCP, tended to have lower values for alkaline phosphatase (P utility in this patient population should be questioned. Further research is needed to better define the pretest characteristics which would predict which patients do not need further intervention after MRCP as well as defining the most cost-effective strategy. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Normal pancreatic exocrine function does not exclude MRI/MRCP chronic pancreatitis findings.

    Science.gov (United States)

    Alkaade, Samer; Cem Balci, Numan; Momtahen, Amir Javad; Burton, Frank

    2008-09-01

    Abnormal pancreatic function tests have been reported to precede the imaging findings of chronic pancreatitis. Magnetic resonance imaging (MRI) with magnetic resonance cholangiopancreatography (MRCP) is increasingly accepted as the primary imaging modality for the detection of structural changes of early mild chronic pancreatitis. The aim of this study was to evaluate MRI/MRCP findings in patients with symptoms consistent with chronic pancreatitis who have normal Secretin Endoscopic Pancreatic Function test. A retrospective study of 32 patients referred for evaluation of chronic abdominal pain consistent with chronic pancreatitis and reported normal standard abdominal imaging (ultrasound, computed tomography, or MRI). All patients underwent Secretin Endoscopic Pancreatic Function testing and pancreatic MRI/MRCP at our institution. We reviewed the MRI/MRCP images in patients who had normal Secretin Endoscopic Pancreatic Function testing. MRI/MRCP images were assessed for pancreatic duct morphology, gland size, parenchymal signal and morphology, and arterial contrast enhancement. Of the 32 patients, 23 had normal Secretin Endoscopic Pancreatic Function testing, and 8 of them had mild to marked spectrum of abnormal MRI/MRCP findings that were predominantly focal. Frequencies of the findings were as follows: pancreatic duct stricture (n=3), pancreatic duct dilatation (n=3), side branch ectasia (n=4), atrophy (n=5), decreased arterial enhancement (n=5), decreased parenchymal signal (n=1), and cavity formation (n=1). The remaining15 patients had normal pancreatic structure on MRI/MRCP. Normal pancreatic function testing cannot exclude abnormal MRI/MRCP especially focal findings of chronic pancreatitis. Further studies needed to verify significance of these findings and establish MRI/MRCP imaging criteria for the diagnosis of chronic pancreatitis.

  3. The diagnostic value of MRI and MRCP in congenital duct cysts and complications

    International Nuclear Information System (INIS)

    Xiao Fang; Huang Suiqiao; Hu Tao

    2009-01-01

    Objective: To investigate the value of MRI and MRCP in diagnosis of congenital duct cysts and their complications. Methods: The MRI and MRCP of 29 cases of congenital duct cyst verified by pathological findings were analyzed retrospectively. Results: In 29 cases of Congenital choledochocele, 10 of which are type lb and 7 were Ic, appearing as the focal choledochal ecstasis, which were connected with the bile duct tree and displayed by MRCP. 10 cases were type IV and 2 are type V, appearing as the multiple cholangiectasis extrahepaticly and/or intrahepaticly and displayed by MRCP as the multiple cystoid with different sizes. There were 7 cases with complication of calculus, 4 in type Ib and 3 in type IV, appearing as single or multiple non-enhanced lesion with clear border. There were 3 cases with complication of tumors, 1 cholangiocarcinoma in type IV and type V respectively, appearing as the enhanced nodus within the wall of dilatant bile duct, 1 gallbladder carcinoma in type lb with multiple liver metastasis. The interruption of distal choledochocele was demonstrated in the complication of biliary atresia in 1 of type V. There was pancreatitis in 1 of type IV. The diagnosis and typing of choledochocele can be accurately made by MRI combined with MRCP, and complications were easily and clearly showed. The accuracy rate for location of choledochocele was 100%. Conclusion: There is an important value for MRI and MRCP examination in diagnosis of congenital bile duct cysts and their complications. (authors)

  4. Allergy Shots (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Allergy Shots KidsHealth / For Parents / Allergy Shots What's in ... to help a child deal with them. Why Allergy Shots Are Used An allergy occurs when the ...

  5. Evaluation of date syrup as an oral negative contrast agent for MRCP.

    Science.gov (United States)

    Govindarajan, Arunkumar; Lakshmanan, Prakash Manikka; Sarawagi, Radha; Prabhakaran, Velu

    2014-11-01

    The purpose of this study was to compare the in vitro effects of date syrup with those of other contrast agents by qualitative and quantitative analysis and in vivo evaluation of the use of date syrup to improve the quality of MRCP images. Phantoms containing date syrup, ferumoxsil, pineapple juice, and water were imaged by 1.5-T MRI with T2-weighted and MRCP sequences, and signal-to-noise ratios were calculated. Biochemical analysis of date syrup was performed to find the nature of iron in it, and the iron content was quantified by energy-dispersive x-ray spectroscopy. Sixty patients underwent MRCP before and 30 minutes after ingestion of 100 mL of date syrup. Unenhanced and contrast-enhanced images were scored for gastrointestinal tract signal suppression and visualization of various pancreaticobiliary structures. In vitro evaluation showed that images obtained with date syrup had a signal-to-noise ratio comparable to that of images obtained with ferumoxsil in T2-weighted and MRCP sequences. The iron concentration in date syrup was 2.6 mg/dL, and it was in ferric form. Images obtained after oral contrast administration had statistically significant improvement in gastrointestinal tract signal suppression (p Date syrup can be used as a negative oral contrast agent for gastrointestinal tract signal suppression during MRCP and for improving visualization of various pancreaticobiliary structures.

  6. Magnetic resonance cholangiopancreatography findings of pancreatic diseases: quantitative analysis

    International Nuclear Information System (INIS)

    Xu Jun; Lu Jianping; Wang Jian; Wang Fei; Liu Qi; Wang Li; Gong Jianguo; Jin Aiguo; Zeng Hao

    2004-01-01

    Objective: To study the MR cholangiopancreatography (MRCP) characteristics of different pancreatic diseases, and to identify the diagnostic value of MRCP for pancreatic diseases. Methods: One hundred and eleven patients with suspected pancreatic diseases underwent MRCP examination. The MRCP sequences included thick-slice turbo spin echo (TSE) and thin-slice half-Fourier acquisition single shot turbo spin echo (HASTE) sequences. The pancreatic diseases included pancreatic carcinoma (n=46), chronic pancreatitis (n=39), peri-ampullar carcinoma (n=23), and choledocholith (n=3). Results: (1) The abnormal manifestation of pancreatic duct was observed in 37 cases of pancreatic carcinoma, 24 cases of chronic pancreatitis, and 12 cases of peri-ampullar carcinoma. Dilated pancreatic duct with smooth and regular caliber was observed in 33 cases of pancreatic carcinoma, 0 case of chronic pancreatitis, and 12 cases of peri-ampullar carcinoma, and statistical analysis showed significant difference (χ 2 =57.911, P 2 =60.343, P 2 =61.217, P 2 =34.654, P 2 =54.593, P<0.01). Conclusion: Different MRI characteristics were observed in various pancreatic diseases respectively. MRCP can show the subtle differences among the pancreatic diseases, and is very helpful in the diagnosis and differential diagnosis of pancreatic diseases

  7. Birth Control Shot

    Science.gov (United States)

    ... Health Food & Fitness Diseases & Conditions Infections Drugs & Alcohol School & Jobs Sports Expert Answers (Q&A) Staying Safe Videos for Educators Search English Español Birth Control Shot KidsHealth / For Teens / Birth Control Shot What's ...

  8. Pancreatic duct abnormalities in focal autoimmune pancreatitis: MR/MRCP imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Negrelli, Riccardo; Manfredi, Riccardo; Pedrinolla, Beatrice; Boninsegna, Enrico; Ventriglia, Anna; Mehrabi, Sara; Pozzi Mucelli, Roberto [G.B. Rossi University Hospital, University of Verona, Department of Radiology, Verona (Italy); Frulloni, Luca [Universita di Verona, Department of Gastroenterology, Policlinico G.B. Rossi, Verona (Italy)

    2014-08-09

    To evaluate the magnetic resonance (MR) imaging-MR cholangiopancreatographic (MRCP) findings of focal forms of autoimmune pancreatitis (AIP) to describe ductal involvement at diagnosis. MR examinations of 123 patients affected by AIP were analysed. We included 26 patients who satisfied International Consensus Diagnostic Criteria and were suffering from focal AIP. Image analysis included: site of parenchymal enlargement, main pancreatic duct (MPD) diameter, MPD stenosis, stricture length, presence of upstream dilation within the stricture, signal intensity, and pancreatic enhancement. Signal intensity abnormalities were localized in the head in 10/26 (38.5 %) and in the body-tail in 16/26 (61.5 %) patients. MRCP showed a single MPD stenosis in 12/26 (46.1 %) and multiple MPD stenosis in 14/26 (53.8 %) patients, without a dilation of the upstream MPD (mean: 3.83 mm). Lesions showed hypointensity on T1-weighted images in all patients, and hyperintensity on T2-weighted images in 22/26 (84.6 %) patients. The affected parenchyma was hypovascular during the arterial phase in 25/26 (96.2 %) patients with contrast retention. MR-MRCP are effective techniques for the diagnosis of AIP showing the loss of the physiological lobulation and the typical contrastographic appearance. The presence of multiple, long stenoses without an upstream MPD dilation at MRCP suggests the diagnosis of AIP, and can be useful in differential diagnosis of pancreatic adenocarcinoma. (orig.)

  9. Assessment of MRI and MRCP in diagnosis of biliary cystadenoma and cystadenocarcinoma

    International Nuclear Information System (INIS)

    Lewin, Maite; Arrive, Lionel; Tubiana, Jean-Michel; Mourra, Najat; Flejou, Jean-Francois; Honigman, Isabelle; Parc, Rolland

    2006-01-01

    Magnetic resonance imaging (MRI) and magnetic resonance cholangio-pancreatography (MRCP) features were analyzed in the diagnosis of seven surgically resected hepatobiliary cystic tumors with reference to histopathological data. Homogeneity, size, location, signal intensity, presence or absence of septa and/or nodules and MRCP features of the lesions were studied. Histological evidence demonstrated six biliary cystadenoma (BCA) including four pseudo-ovarian stroma (POS) and one biliary cystadenocarcinoma (BCAC). Cystic lesions (3-15 cm in diameter) were homogeneous in the six BCA, heterogeneous in the one BCAC, and were located in the left and right liver, respectively. On T2-weighted images all lesions were hyperintense. On T1-weighted images hypointensity was found in three BCA (all serous fluid, including one POS), isointensity was found in the three others (two mucinous and one hemorrhagic fluid, including three POS) and in the one BCAC (containing mucinous fluid). Septas were present in all cases and nodules only in the one BCAC. On MRCP a hyperintense cystic lesion was found in all cases and a bile ducts dilatation in two BCA and the one BCAC. Gadolinium-enhanced MRI in combination with MRCP is a valuable tool for the diagnosis of BCA or BCAC. However, no specific information is gained for POS detection. (orig.)

  10. Utility of single shot fast spin echo technique in evaluating pancreaticobiliary diseases: T2-weighted image and magnetic resonance cholangiopancreatography

    International Nuclear Information System (INIS)

    Choi, Byoung Wook; Kim, Myeong Jin; Chung, Jae Bok; Ko, Heung Kyu; Kim, Dong Joon; Kim, Joo Hee; Chung, Jae Joon; Yoo, Hyung Sik; Lee, Jong Tae

    1999-01-01

    To evaluate the accuracy of T2-weighted imaging an MR cholangiopancreatography using the single shot fast spin-echo technique for evaluating pancreaticobiliary disease. Between March and July 1997, axial and coronal T2-weighted images(TE: 80-200 msec) and MR cholangiopancreatograms (TE: 800-1200 msec) were obtained in two ways [single slab (thickness: 30-50 mm) and multislice acquisition under chemical fat saturation] using SSFSE pulse sequencing in 131 cases of suspected pancreati-cobiliary disease. The accuracy of SSFSE MR imaging was assessed in 89 lesions of 74 patients [male, 48; female, 26; age range, 30-86 (mean, 59) years] confirmed surgicopathologically (50 lesions in 39 patients) and clinically (39 lesions in 35 patients). Two radiologists reviewed the MR images and diagnosis was determined by consensus. Correct diagnosis was confirmed in 84 of 89 lesions (94%). Seven lesions were falsely interpreted, false positive and false negative results accounting for two and five cases, respectively. Two pancreatic cancers were misdiagnosed as pancreatitis and a cancer of the proximal common bile duct(CBD) was interpreted as a distal CBD cancer. The sensitivity of SSFSE MR imaging for malignancy was 93 %. One CBD stone revealed by endoscopic retrograde cholangiopancreatography (ERCP) was not detected on MR images. In contrast, a stone in the CBD seen on MR images was not apparent on subsequent ERCP. Sensitivity and specificity for calculous disease were 96% and 99.7%, respectively. A benign stricture of the ampulla of Vater was falsely interpreted as normal, and correct diagnosis was possible in two falsely diagnosed cases when MR images were reviewed retrospectively. The combination of T2-weighted and cholangiographic images using SSFSE is an accurate method for diagnosing pancreatcobiliary diseases

  11. PLAB and UK graduates’ performance on MRCP(UK) and MRCGP examinations: data linkage study

    Science.gov (United States)

    Wakeford, Richard

    2014-01-01

    Objectives To assess whether international medical graduates passing the two examinations set by the Professional and Linguistic Assessments Board (PLAB1 and PLAB2) of the General Medical Council (GMC) are equivalent to UK graduates at the end of the first foundation year of medical training (F1), as the GMC requires, and if not, to assess what changes in the PLAB pass marks might produce equivalence. Design Data linkage of GMC PLAB performance data with data from the Royal Colleges of Physicians and the Royal College of General Practitioners on performance of PLAB graduates and UK graduates at the MRCP(UK) and MRCGP examinations. Setting Doctors in training for internal medicine or general practice in the United Kingdom. Participants 7829, 5135, and 4387 PLAB graduates on their first attempt at MRCP(UK) Part 1, Part 2, and PACES assessments from 2001 to 2012 compared with 18 532, 14 094, and 14 376 UK graduates taking the same assessments; 3160 PLAB1 graduates making their first attempt at the MRCGP AKT during 2007-12 compared with 14 235 UK graduates; and 1411 PLAB2 graduates making their first attempt at the MRCGP CSA during 2010-12 compared with 6935 UK graduates. Main outcome measures Performance at MRCP(UK) Part 1, Part 2, and PACES assessments, and MRCGP AKT and CSA assessments in relation to performance on PLAB1 and PLAB2 assessments, as well as to International English Language Testing System (IELTS) scores. MRCP(UK), MRCGP, and PLAB results were analysed as marks relative to the pass mark at the first attempt. Results PLAB1 marks were a valid predictor of MRCP(UK) Part 1, MRCP(UK) Part 2, and MRCGP AKT (r=0.521, 0.390, and 0.490; all PIELTS scores correlated significantly with later performance, multiple regression showing that the effect of PLAB1 (β=0.496) was much stronger than the effect of IELTS (β=0.086). Changes to PLAB pass marks that would result in international medical graduate and UK medical graduate equivalence were assessed in two

  12. PLAB and UK graduates' performance on MRCP(UK) and MRCGP examinations: data linkage study.

    Science.gov (United States)

    McManus, I C; Wakeford, Richard

    2014-04-17

    To assess whether international medical graduates passing the two examinations set by the Professional and Linguistic Assessments Board (PLAB1 and PLAB2) of the General Medical Council (GMC) are equivalent to UK graduates at the end of the first foundation year of medical training (F1), as the GMC requires, and if not, to assess what changes in the PLAB pass marks might produce equivalence. Data linkage of GMC PLAB performance data with data from the Royal Colleges of Physicians and the Royal College of General Practitioners on performance of PLAB graduates and UK graduates at the MRCP(UK) and MRCGP examinations. Doctors in training for internal medicine or general practice in the United Kingdom. 7829, 5135, and 4387 PLAB graduates on their first attempt at MRCP(UK) Part 1, Part 2, and PACES assessments from 2001 to 2012 compared with 18,532, 14,094, and 14,376 UK graduates taking the same assessments; 3160 PLAB1 graduates making their first attempt at the MRCGP AKT during 2007-12 compared with 14,235 UK graduates; and 1411 PLAB2 graduates making their first attempt at the MRCGP CSA during 2010-12 compared with 6935 UK graduates. Performance at MRCP(UK) Part 1, Part 2, and PACES assessments, and MRCGP AKT and CSA assessments in relation to performance on PLAB1 and PLAB2 assessments, as well as to International English Language Testing System (IELTS) scores. MRCP(UK), MRCGP, and PLAB results were analysed as marks relative to the pass mark at the first attempt. PLAB1 marks were a valid predictor of MRCP(UK) Part 1, MRCP(UK) Part 2, and MRCGP AKT (r=0.521, 0.390, and 0.490; all PIELTS scores correlated significantly with later performance, multiple regression showing that the effect of PLAB1 (β=0.496) was much stronger than the effect of IELTS (β=0.086). Changes to PLAB pass marks that would result in international medical graduate and UK medical graduate equivalence were assessed in two ways. Method 1 adjusted PLAB pass marks to equate median performance of PLAB

  13. Noninvasive investigation of exocrine pancreatic function: Feasibility of cine dynamic MRCP with a spatially selective inversion-recovery pulse.

    Science.gov (United States)

    Yasokawa, Kazuya; Ito, Katsuyoshi; Tamada, Tsutomu; Yamamoto, Akira; Hayashida, Minoru; Tanimoto, Daigo; Higaki, Atsushi; Noda, Yasufumi; Kido, Ayumu

    2015-11-01

    To investigate the feasibility of noncontrast-enhanced cine dynamic magnetic resonance cholangiopancreatography (MRCP) with a spatially selective inversion-recovery (IR) pulse for evaluating exocrine pancreatic function in comparison with the N-benzoyl-L-tyrosyl-p-aminobenzoic acid (BT-PABA) test as a pancreatic exocrine function test. Twenty subjects with or without chronic pancreatitis were included. MRCP with a spatially selective IR pulse was repeated every 15 seconds for 5 minutes to acquire a total of 20 images (cine-dynamic MRCP). The median and mean frequency of the observation (the number of times) and the moving distance (mean secretion grading scores) of pancreatic juice inflow on cine-dynamic MRCP were compared with a BT-PABA test. The urinary PABA excretion rate (%) had significant positive correlations with both the mean secretion grade (r = 0.66, P = 0.002) and frequency of secretory inflow (r = 0.62, P = 0.004) in cine dynamic MRCP. Both the mean frequency of observations of pancreatic secretory inflow (1.4 ± 1.6 times vs. 14.3 ± 4.2 times, P Cine dynamic MRCP with a spatially selective IR pulse may have potential for estimating the pancreatic exocrine function noninvasively as a substitute for the BT-PABA test. © 2015 Wiley Periodicals, Inc.

  14. An incidental case of biliary fascioliasis with subtle clinical findings: US and MRCP findings

    International Nuclear Information System (INIS)

    Önder, Hakan; Ekici, Faysal; Adin, Emin; Kuday, Suzan; Gümüş, Hatice; Bilici, Aslan

    2013-01-01

    Fascioliasis is a disease caused by the trematode Fasciola hepatica. Cholangitis is a common clinical manifestation. Although fascioliasis may show various radiological and clinical features, cases without biliary dilatation are rare. We present unique ultrasound (US) and magnetic resonance cholangiopancreatography (MRCP) findings of a biliary fascioliasis case which doesn’t have biliary obstruction or cholestasis. Radiologically, curvilinear parasites compatible with juvenile and mature Fasciola hepatica within the gallbladder and common bile duct were found. The parasites appear as bright echogenic structures with no acoustic shadow on US and hypo-intense curvilinear lesions on T2 weighted MRCP images. Imaging studies may significantly contribute to the diagnosis of patients with subtle clinical and laboratory findings, particularly in endemic regions

  15. The exploratory development of A self-made oral Gd-DTPA solution for low field MRCP in children

    International Nuclear Information System (INIS)

    Sheng Mao; Zhou Min; Gu Zhicheng; Wu Jizhi; Guo Wanliang; Ni Yongbiao; Fang Lin

    2010-01-01

    Objective: To evaluate the value of ingestion self-made Gd-DTPA solutin for low field magnetic resonance cholangiopancreatography (MRCP) (0.35T) in children. Methods: Phantom experiments were performed to select the optimal concentration of Gd-DTPA to be used as an oral negative contrast agent in low field MRCP. Twenty children suspected of celiac disease were performed with MRCP before and after ingestion Gd-DTPA solution. Signal intensity measurements of gastroduodenal lumens, pancreatobiliary ducts, and image quality scores were obtained systematically before and after contrast ingestion. Results: The selected Gd-DTPA concentration was 1.992 mmol/L. Ingestion of 80 ml solution eliminated or suppressed efficiently the gastroduodenal signal intensity, improving the MRCP image quality scores (P<0.01) significantly in children. Conclusion: 1.992 mmol/L self-made Gd-DTPA solutin can suppress or eliminate water signals from gastrointestinal tract and improve the quality of low field MRCP image in children. (authors)

  16. Generalised shot noise Cox processes

    DEFF Research Database (Denmark)

    Møller, Jesper; Torrisi, Giovanni Luca

    2005-01-01

    We introduce a class of cox cluster processes called generalised shot noise Cox processes (GSNCPs), which extends the definition of shot noise Cox processes (SNCPs) in two directions: the point process that drives the shot noise is not necessarily Poisson, and the kernel of the shot noise can...

  17. MRCP and 3D LAVA imaging of extrahepatic cholangiocarcinoma at 3 T MRI

    Energy Technology Data Exchange (ETDEWEB)

    Li, N.; Liu, C.; Bi, W.; Lin, X.; Jiao, H. [Shandong Medical Imaging Research Institute, Shandong University, Jinan (China); Zhao, P., E-mail: Gavinsdu@163.com [Department of Radiology, Shandong Provincial Hospital, Shandong University, Jinan (China)

    2012-06-15

    Extrahepatic cholangiocarcinoma (CCA) is a primary bile duct malignant tumour with poor prognosis. Familiarity with their varied imaging characteristics can be helpful in developing a correct diagnosis and in optimal treatment planning, and thus contribute to a better prognosis. The purpose of this article is to illustrate the typical appearances of extrahepatic CCA on magnetic resonance cholangiopancreatography (MRCP) and three-dimensional (3D) LAVA (liver acquisition with volume acceleration) sequences at 3 T magnetic resonance imaging (MRI), and to discuss the superiority of the two techniques in the diagnosis of CCA.

  18. Single dose oral ranitidine improves MRCP image quality: a double-blind study

    International Nuclear Information System (INIS)

    Bowes, M.T.; Martin, D.F.; Melling, A.; Roberts, D.; Laasch, H.-U.; Sukumar, S.; Morris, J.

    2007-01-01

    Aim: To investigate the possibility of whether a single 300 mg dose of ranitidine given orally 2-3 h before magnetic resonance cholangiopancreatography (MRCP) could reduce the signal from the stomach and duodenum, and thus increase the conspicuousness of the biliary tree. Materials and methods: Thirty-five volunteers (22 female, 13 male), (age range 21-50) were underwent MRCP in a double-blind, placebo-controlled, randomized, crossover trial on a Philips Intera 1.5 T machine using a phased array surface coil. Imaging was carried out in the coronal oblique plane. Six 40 mm sections were acquired at varying angles to delineate the biliary tree and pancreatic duct. The 70 examinations were blindly scored by three consultants experienced in cholangiography. Results: After ranitidine administration there was a significant decrease in signal from the stomach (mean = 17.7, p = 0.0005, CI 10, 25.3) and duodenum (mean = 18.4, p = 0.0005, 95%CI 9.6, 27.1) with a significant increase in conspicuousness of the distal common duct (mean = 7.7, p = 0.033, 95%CI 0.7, 14.7) and proximal common duct (mean = 8.7, p = 0.010 CI 2.2, 15.2). There were no adverse effects. Conclusion: Oral ranitidine is a cheap and effective agent to decrease signal from the upper gastrointestinal tract and to improve visibility of the biliary tree

  19. Shot loading platform analysis

    International Nuclear Information System (INIS)

    Norman, B.F.

    1994-01-01

    This document provides the wind/seismic analysis and evaluation for the shot loading platform. Hand calculations were used for the analysis. AISC and UBC load factors were used in this evaluation. The results show that the actual loads are under the allowable loads and all requirements are met

  20. Kids Guide to Shots

    Science.gov (United States)

    ... First Aid & Safety Doctors & Hospitals Videos Recipes for Kids Kids site Sitio para niños How the Body ... Safe Videos for Educators Search English Español A Kid's Guide to Shots KidsHealth / For Kids / A Kid's ...

  1. Vergleich von 2D- und 3D-Sequenzen für die MRCP. Klinischer Stellenwert der einzelnen Techniken

    NARCIS (Netherlands)

    Wallnoefer, A. M.; Herrmann, K. A.; Beuers, U.; Zech, C. J.; Gourtsoyianni, S.; Reiser, M. F.; Schoenberg, S. O.

    2005-01-01

    Magnetic resonance cholangio-pancreaticograpy (MRCP) is a non-invasive imaging modality of the pancreatico-biliary system which plays an increasingly important role in the clinical and diagnostic workup of patients with biliary or pancreatic diseases. The present review is designed to give an

  2. Implementing statistical equating for MRCP(UK) Parts 1 and 2.

    Science.gov (United States)

    McManus, I C; Chis, Liliana; Fox, Ray; Waller, Derek; Tang, Peter

    2014-09-26

    The MRCP(UK) exam, in 2008 and 2010, changed the standard-setting of its Part 1 and Part 2 examinations from a hybrid Angoff/Hofstee method to statistical equating using Item Response Theory, the reference group being UK graduates. The present paper considers the implementation of the change, the question of whether the pass rate increased amongst non-UK candidates, any possible role of Differential Item Functioning (DIF), and changes in examination predictive validity after the change. Analysis of data of MRCP(UK) Part 1 exam from 2003 to 2013 and Part 2 exam from 2005 to 2013. Inspection suggested that Part 1 pass rates were stable after the introduction of statistical equating, but showed greater annual variation probably due to stronger candidates taking the examination earlier. Pass rates seemed to have increased in non-UK graduates after equating was introduced, but was not associated with any changes in DIF after statistical equating. Statistical modelling of the pass rates for non-UK graduates found that pass rates, in both Part 1 and Part 2, were increasing year on year, with the changes probably beginning before the introduction of equating. The predictive validity of Part 1 for Part 2 was higher with statistical equating than with the previous hybrid Angoff/Hofstee method, confirming the utility of IRT-based statistical equating. Statistical equating was successfully introduced into the MRCP(UK) Part 1 and Part 2 written examinations, resulting in higher predictive validity than the previous Angoff/Hofstee standard setting. Concerns about an artefactual increase in pass rates for non-UK candidates after equating were shown not to be well-founded. Most likely the changes resulted from a genuine increase in candidate ability, albeit for reasons which remain unclear, coupled with a cognitive illusion giving the impression of a step-change immediately after equating began. Statistical equating provides a robust standard-setting method, with a better

  3. ZAPP shot summary

    Energy Technology Data Exchange (ETDEWEB)

    Loisel, Guillaume Pascal [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-10-01

    This was the second Z Astrophysical Plasma Properties (ZAPP) fundamental science shot series of 2015. ZAPP experiments measure fundamental properties of atoms in plasmas to solve the following important astrophysical puzzles: Why can’t we accurately model the opacity of Fe at the convection zone boundary in the Sun? How accurate are the photoionization models used to interpret data from xray satellite observations? and Why doesn’t spectral fitting provide the correct properties for White Dwarfs?

  4. One-shot synesthesia

    Directory of Open Access Journals (Sweden)

    Kirschner Alexandra

    2017-11-01

    Full Text Available Synesthesia is commonly thought to be a phenomenon of fixed associations between an outside inducer and a vivid concurrent experience. Hence, it has been proposed that synesthesia occurs due to additional connections in the brain with which synesthetes are born. Here we show that synesthesia can be a much richer and more flexible phenomenon with a capability to creatively construct novel synesthetic experiences as events unfold in people’s lives. We describe here cases of synesthetes who occasionally generate novel synesthetic experience, called one-shot synesthesias. These synesthetic experiences seem to share all the properties with the classical synesthetic associations except that they occur extremely rarely, people recalling only a few events over the lifetime. It appears that these one-shots are not created at random but are instead responses to specific life events. We contrast the properties of those rare synesthetic events with other, more commonly known forms of synesthesia that also create novel synesthetic experiences, but at a high rate—sometimes creating novel experiences every few seconds. We argue that one-shot synesthesias indicate that synesthetic associations are by their nature not prewired at birth but are dynamically constructed through mental operations and according to the needs of a synesthetic mind. Our conclusions have implications for understanding the biological underpinnings of synesthesia and the role the phenomenon plays in the lives of people endowed with synesthetic capacities.

  5. An increased flip angle in late phase Gd-EOB-DTPA MRI shows improved performance in bile duct visualization compared to T2w-MRCP

    Energy Technology Data Exchange (ETDEWEB)

    Stelter, Lars, E-mail: lars.stelter@charite.de [Klinik für Radiologie, Charité – Universitätsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Freyhardt, Patrick, E-mail: patrick.freyhardt@charite.de [Klinik für Radiologie, Charité – Universitätsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Grieser, Christian, E-mail: christian.grieser@charite.de [Klinik für Radiologie, Charité – Universitätsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Walter, Thula, E-mail: thula.walter@charite.de [Klinik für Radiologie, Charité – Universitätsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Geisel, Dominik, E-mail: dominik.geisel@charite.de [Klinik für Radiologie, Charité – Universitätsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Baur, Alexander, E-mail: alexander.baur@charite.de [Klinik für Radiologie, Charité – Universitätsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); and others

    2014-10-15

    Highlights: • EOB-MRC acquired with a flip angle of 35° revealed a better diagnostic performance compared to T2w-MRCP. • EOB-MRC increased the readers’ confidence in identifying anatomic variations of the biliary tree. • As EOB-MRC comprises functional information it is a valuable adjunct to T2w-MRCP. - Abstract: Objectives: To estimate the additional value of an increased flip angle of 35° in late phase Gd-EOB-DTPA-enhanced magnetic resonance cholangiography, as compared to T2w-MRCP. Methods: 40 adult patients underwent Gd-EOB-DTPA enhanced MRI of the liver including a T2-weighted 3D TSE MRCP (T2w-MRCP) as well as a late phase T1-weighted THRIVE sequences applying a flip angle of 35° (fa35). Two experienced observers evaluated the images regarding the delineation of the different biliary regions using a three-point grading system. A five-point scale was applied to determine the readers’ confidence in identifying anatomical variations of the biliary tree. ROI analysis was performed to compare the signal-to-noise (SNR) and contrast-to-noise (CNR) ratios. Results: The quality for visualizing the biliary tree differed between T2w-MRCP and fa35 (p = <0.001). Late phase EOB-MRC was rated as good for delineating the entire biliary system, whereas T2w-MRCP received an overall poor rating. Especially the depiction of the intrahepatic bile ducts was estimated as problematic in T2w-MRCP. T2w-MRCP and fa35 revealed a discordant assessment of anatomical variations in 12.5% of the cases, comprising a generally higher confidence level for fa35 (4.0 ± 1.1 vs. 2.2 ± 1.2, p = <0.001). SNR proofed to be significantly higher in fa35 (p = <0.001), whereas T2w-MRCP revealed a significantly higher CNR (<0.001). Conclusions: Gd-EOB-DTPA enhanced magnetic resonance cholangiography acquired with a flip angle of 35° revealed a better diagnostic performance compared to T2w-MRCP and might be a valuable adjunct in assessing functional bile duct abnormalities.

  6. Postprandial changes in secretory flow of pancreatic juice in the main pancreatic duct: evaluation with cine-dynamic MRCP with a spatially selective inversion-recovery (IR) pulse.

    Science.gov (United States)

    Yasokawa, Kazuya; Ito, Katsuyoshi; Tamada, Tsutomu; Yamamoto, Akira; Hayashida, Minoru; Torigoe, Teruyuki; Tanimoto, Daigo; Higaki, Atsushi; Noda, Yasufumi; Kido, Ayumu

    2016-12-01

    To evaluate the influence of oral ingestion on the secretory flow dynamics of physiological pancreatic juice within the main pancreatic duct in healthy subjects by using cine-dynamic MRCP with spatially-selective inversion-recovery (IR) pulse non-invasively. Thirty-eight healthy subjects were investigated. MRCP with spatially-selective IR pulse was repeated every 15 s for 5 min to acquire a total of 20 images (cine-dynamic MRCP). A set of 20 MRCP images was repeatedly obtained before and after liquid oral ingestion every 7 min (including 2-min interval) for 40 min (a total of seven sets). Secretion grade of pancreatic juice on cine-dynamic MRCP was compared before and after oral ingestion using the nonparametric Wilcoxon signed-rank test. Median secretion grades of pancreatic juice at 5 min (score = 2.15), 12 min (score = 1.95) and 19 min (score = 2.05) after ingestion were significantly higher than that before ingestion (score = 1.40) (P = 0.004, P = 0.032, P = 0.045, respectively). Secretion grade of pancreatic juice showed a maximum peak of 2.15 at 5 min after ingestion. Thereafter, the secretion grade of pancreatic juice tended to gradually decline. Non-invasive cine-dynamic MRCP using spatially-selective IR pulse showed potential for evaluating postprandial changes in the secretory flow dynamics of pancreatic juice as a physiological reaction. • Secretion grade of pancreatic juice at cine-dynamic MRCP after ingestion was evaluated. • Secretion grade was significantly increased within 19 min after liquid meal ingestion. • Secretion grade showed maximum peak of 2.15 at 5 min after ingestion. • Postprandial changes in pancreatic juice flow can be assessed by cine-dynamic MRCP.

  7. Postprandial changes in secretory flow of pancreatic juice in the main pancreatic duct: evaluation with cine-dynamic MRCP with a spatially selective inversion-recovery (IR) pulse

    International Nuclear Information System (INIS)

    Yasokawa, Kazuya; Ito, Katsuyoshi; Tamada, Tsutomu; Yamamoto, Akira; Hayashida, Minoru; Torigoe, Teruyuki; Tanimoto, Daigo; Higaki, Atsushi; Noda, Yasufumi; Kido, Ayumu

    2016-01-01

    To evaluate the influence of oral ingestion on the secretory flow dynamics of physiological pancreatic juice within the main pancreatic duct in healthy subjects by using cine-dynamic MRCP with spatially-selective inversion-recovery (IR) pulse non-invasively. Thirty-eight healthy subjects were investigated. MRCP with spatially-selective IR pulse was repeated every 15 s for 5 min to acquire a total of 20 images (cine-dynamic MRCP). A set of 20 MRCP images was repeatedly obtained before and after liquid oral ingestion every 7 min (including 2-min interval) for 40 min (a total of seven sets). Secretion grade of pancreatic juice on cine-dynamic MRCP was compared before and after oral ingestion using the nonparametric Wilcoxon signed-rank test. Median secretion grades of pancreatic juice at 5 min (score = 2.15), 12 min (score = 1.95) and 19 min (score = 2.05) after ingestion were significantly higher than that before ingestion (score = 1.40) (P = 0.004, P = 0.032, P = 0.045, respectively). Secretion grade of pancreatic juice showed a maximum peak of 2.15 at 5 min after ingestion. Thereafter, the secretion grade of pancreatic juice tended to gradually decline. Non-invasive cine-dynamic MRCP using spatially-selective IR pulse showed potential for evaluating postprandial changes in the secretory flow dynamics of pancreatic juice as a physiological reaction. (orig.)

  8. Biliary anatomy in potential right hepatic lobe living donor liver transplantation (LDLT): The utility of CT cholangiography in the setting of inconclusive MRCP

    International Nuclear Information System (INIS)

    McSweeney, Sean E.; Kim, Tae Kyoung; Jang, Hyun-Jung; Khalili, Korosh

    2012-01-01

    Objective: To determine the utility of CT cholangiography (CT-Ch) in preoperative evaluation of the biliary anatomy of living-donor liver transplantation (LDLT) donors when magnetic resonance cholangiopancreatography (MRCP) is inconclusive. Materials and methods: Over a 2-year period, 22 potential living liver donors underwent contrast-enhanced CT-Ch for preoperative evaluating biliary anatomy due to inconclusive results on MRCP and subsequently donated their right hepatic lobe. Nineteen of them underwent intraoperative cholangiography and were included in this study. Two radiologists retrospectively reviewed both MRCP and CT-Ch with 1-month interval and documented the types of bile duct branching patterns and visualization score of intrahepatic bile ducts (4-point scale). Results: There were no complications associated with CT-Ch examinations. CT-Ch was concordant with the reference standard in 18/19 (95%) including 7/8 typical branching type and 11/11 anomalous branching types. MRCP was concordant with the reference standard in 14/19 (74%) including 4/8 typical branching types and 10/11 anomalous branching types. The discordant case by CT-Ch was the identification of a tiny accessory right intrahepatic duct joining the common bile duct which was not visualized on intraoperative cholangiography. CT-Ch showed higher visualization score (mean, 3.9) than MRCP (mean, 2.6) (P < .001). Conclusion: CT-Ch can be effectively used for the depiction of the branching pattern of the bile duct at the hepatic hilum when MRCP is inconclusive.

  9. Postprandial changes in secretory flow of pancreatic juice in the main pancreatic duct: evaluation with cine-dynamic MRCP with a spatially selective inversion-recovery (IR) pulse

    Energy Technology Data Exchange (ETDEWEB)

    Yasokawa, Kazuya; Ito, Katsuyoshi; Tamada, Tsutomu; Yamamoto, Akira; Hayashida, Minoru; Torigoe, Teruyuki; Tanimoto, Daigo; Higaki, Atsushi; Noda, Yasufumi; Kido, Ayumu [Kawasaki Medical School, Department of Diagnostic Radiology, Kurashiki, Okayama (Japan)

    2016-12-15

    To evaluate the influence of oral ingestion on the secretory flow dynamics of physiological pancreatic juice within the main pancreatic duct in healthy subjects by using cine-dynamic MRCP with spatially-selective inversion-recovery (IR) pulse non-invasively. Thirty-eight healthy subjects were investigated. MRCP with spatially-selective IR pulse was repeated every 15 s for 5 min to acquire a total of 20 images (cine-dynamic MRCP). A set of 20 MRCP images was repeatedly obtained before and after liquid oral ingestion every 7 min (including 2-min interval) for 40 min (a total of seven sets). Secretion grade of pancreatic juice on cine-dynamic MRCP was compared before and after oral ingestion using the nonparametric Wilcoxon signed-rank test. Median secretion grades of pancreatic juice at 5 min (score = 2.15), 12 min (score = 1.95) and 19 min (score = 2.05) after ingestion were significantly higher than that before ingestion (score = 1.40) (P = 0.004, P = 0.032, P = 0.045, respectively). Secretion grade of pancreatic juice showed a maximum peak of 2.15 at 5 min after ingestion. Thereafter, the secretion grade of pancreatic juice tended to gradually decline. Non-invasive cine-dynamic MRCP using spatially-selective IR pulse showed potential for evaluating postprandial changes in the secretory flow dynamics of pancreatic juice as a physiological reaction. (orig.)

  10. Centrifugal shot blast system

    International Nuclear Information System (INIS)

    1998-02-01

    This report describes a demonstration of Concrete cleaning, Inc., modified centrifugal shot blast technology to remove the paint coating from concrete flooring. This demonstration is part of the Chicago Pile-5 (CP-5) Large-Scale Demonstration Project (LSDP) sponsored by the US Department of Energy (DOE), office of Science and Technology (OST), Deactivation and Decommissioning Focus Area (DDFA). The objective of the LSDP is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East (ANL) CP-5 Research Reactor. The purpose of the LSDP is to demonstrate that using innovative and improved decontamination and decommissioning (D and D) technologies from various sources can result in significant benefits, such as decreased cost and increased health and safety, as compared with baseline D and D technologies. Potential markets exist for the innovative centrifugal shot blast system at the following sites: Fernald Environmental Management Project, Los Alamos, Nevada, Oak Ridge Y-12 and K-25, Paducah, Portsmouth Gaseous Diffusion site, and the Savannah River Site. This information is based on a revision to the OST Linkage Tables dated August 4, 1997

  11. Focal Pancreatitis Mimicking Pancreatic Mass: Magnetic Resonance Imaging (MRI)/Magnetic Resonance Cholangiopancreatography (MRCP) Findings Including Diffusion-Weighted MRI

    International Nuclear Information System (INIS)

    Momtahen, A.J.; Balci, N.C.; Alkaade, S.; Akduman, E.I.; Burton, F.R.

    2008-01-01

    Background: Focal pancreatitis (FP) is a confined inflammation that mimics a pancreatic mass. Its imaging diagnosis is important to avoid unnecessary procedures. Purpose: To describe the spectrum of magnetic resonance imaging (MRI)/magnetic resonance cholangiopancreatography (MRCP) and diffusion-weighted MRI (DWI) findings of focal pancreatitis mimicking pancreatic masses. Material and Methods: Findings of MRI/MRCP including DWI with a b value of 0 and 600 s/mm2 in 14 patients with pancreatic masses on MRI were retrospectively reviewed and compared to normal pancreas in 14 patients as a control group. Results: FP revealed hypointense signal intensity (SI) (3/14), hypo- to isointense SI (7/14), or isointense SI (4/14) on T1-weighted images, and hypointense SI (1/14), isointense SI (5/14), iso- to hyperintense SI (7/14), or hyperintense SI (1/14) on T2-weighted images compared to remaining pancreas (RP). MRCP images revealed dilatation of the common bile duct (CBD) and main pancreatic duct (MPD) (5/14), dilatation of the MPD only (3/14), dilatation of the CBD only (3/14), and normal MPD and CBD (3/14). Both FP and RP revealed three types of time-signal intensity curves: 1) rapid rise to a peak, with a rapid decline (FP=2, RP=4), 2) slow rise to a peak, followed by a slow decline (FP=5, RP=4), and 3) slower rise to a peak, with a slow decline or plateau (FP=7, RP=6). Mean apparent diffusion coefficient (ADC) values for FP and RP were 2.09±0.18 and 2.03±0.2x10 -3 mm 2 /s, respectively. ADC values of FP and RP revealed no significant difference. Conclusion: The spectrum of imaging findings of focal pancreatitis on MRI/MRCP including DWI was described. Findings of FP were not distinctive as compared to the remaining pancreas

  12. Buster-Jangle Shot Dog

    International Nuclear Information System (INIS)

    Kaul, Dean C.

    1987-01-01

    Shot Dog of the Buster-Jangle Series used a device which had a high-explosive configuration virtually identical to that of the Nagasaki bomb, though with different fissionable components. Dog was detonated at a height of 431.9 m with the mean atmospheric conditions between burst and ground being dry air density 1.027 mg/cc and atmospheric moisture density 0.006 mg/cc. The ground was taken to be that of Nevada test site (NTS) area 9 with a water content of 8% by weight. The yield of the weapon was 21 kt. Results shown here for Buster-Jangle Shot Dog have been scaled from those calculated for Ranger Shot Fox. The design features and burst geometries of the two devices were deemed sufficiently similar to make this substitution in the absence of a radiation leakage spectrum calculated explicitly for Buster-Jangle Shot Dog. However, while the relative atmospheric contents of the two shots were very similar, Shot Fox took place in air of approximately 10% greater density than Shot Dog. Thus, scaled calculated results could not be obtained to compare with the three closest measurement points at Shot Dog

  13. The effect of mastication on human motor preparation processing: a study with CNV and MRCP.

    Science.gov (United States)

    Sakamoto, Kiwako; Nakata, Hiroki; Honda, Yukiko; Kakigi, Ryusuke

    2009-07-01

    To clarify the effect of mastication on motor preparation processing using electroencephalography (EEG), we investigated the effect of mastication on contingent negative variation (CNV) and reaction time (RT) in Experiment 1, and movement-related cortical potentials (MRCPs) in Experiment 2. The twelve subjects performed four CNV or MRCP sessions, and in the Mastication condition chewed a gum base during the resting period between sessions, Pre (before chewing) and Post 1, 2, and 3 (after chewing). In the Control condition, the subjects performed the same sessions without chewing gum during the intervals between sessions on another day. In Experiment 1, the mean amplitudes of the early- and late-CNV were significantly larger in Mastication than Control at Post 2 and Post 3. RT also differed significantly between Mastication and Control at Post 3. By contrast, in Experiment 2, there were no significant differences between Mastication and Control for the mean amplitudes of MRCPs including Bereitschaftspotential (BP) and negative slope (NS') in any session. These results suggest that mastication influences cognitive processing reflected by CNV with stimulus-triggered movement, rather than motor-related processing reflected by MRCPs relating to self-initiated movement, and provide evidence concerning the mechanisms for the effect of mastication on the human brain.

  14. Generalised shot noise Cox processes

    DEFF Research Database (Denmark)

    Møller, Jesper; Torrisi, Giovanni Luca

    We introduce a new class of Cox cluster processes called generalised shot-noise processes (GSNCPs), which extends the definition of shot noise Cox processes (SNCPs) in two directions: the point process which drives the shot noise is not necessarily Poisson, and the kernel of the shot noise can...... be random. Thereby a very large class of models for aggregated or clustered point patterns is obtained. Due to the structure of GSNCPs, a number of useful results can be established. We focus first on deriving summary statistics for GSNCPs and next on how to make simulation for GSNCPs. Particularly, results...... for first and second order moment measures, reduced Palm distributions, the -function, simulation with or without edge effects, and conditional simulation of the intensity function driving a GSNCP are given. Our results are exemplified for special important cases of GSNCPs, and we discuss the relation...

  15. Magnetic resonance cholangiopancreatography (MRCP) using new negative per-oral contrast agent based on superparamagnetic iron oxide nanoparticles for extrahepatic biliary duct visualization in liver cirrhosis.

    Science.gov (United States)

    Polakova, Katerina; Mocikova, Ingrid; Purova, Dana; Tucek, Pavel; Novak, Pavel; Novotna, Katerina; Izak, Niko; Bielik, Radoslav; Zboril, Radek; Miroslav, Herman

    2016-12-01

    Magnetic resonance cholangiopancreatography (MRCP) is often used for imaging of the biliary tree and is required by surgeons before liver transplantation. Advanced liver cirrhosis and ascites in patients however present diagnostic problems for MRCP. The aim of this study was to find out if the use of our negative per-oral contrast agent containing superparamagnetic iron oxide nanoparticles (SPIO) in MRCP is helpful for imaging of hepatobiliary tree in patients with liver cirrhosis. Forty patients with liver cirrhosis were examined on a 1.5 T MR unit using standard MRCP protocol. Twenty patients (group A) underwent MRCP after administration of per-oral SPIO contrast agent 30 min before examination. In group B, twenty patients were examined without per-oral bowel preparation. Ascites was present in eleven patients from group A and in thirteen patients in group B. Four radiologists analyzed MR images for visibility and delineation of the biliary tree. χ 2 tests were used for comparison of the visibility of intrahepatic and extrahepatic biliary ducts in patients with and without ascites. Better extrahepatic biliary duct visualization and visibility of extraluminal pathologies in patients with ascites was proved after administration of SPIO contrast agent. No statistically significant difference between group A and B was found for visualization of extrahepatic biliary ducts in patients without ascites. Delineation of intrahepatic biliary ducts was independent on bowel preparation. Application of our negative per-oral SPIO contrast agent before MRCP improves the visualization of extrahepatic biliary ducts in patients with ascites which is helpful during the liver surgery, mainly in liver transplantation.

  16. Secretin-stimulating MRCP in patients with pancreatobiliary maljunction and occult pancreatobiliary reflux: direct demonstration of pancreatobiliary reflux

    Energy Technology Data Exchange (ETDEWEB)

    Motosugi, Utaroh; Ichikawa, Tomoaki; Araki, Tsutomu [University of Yamanashi, Department of Radiology, Chuo-shi, Yamanashi (Japan); Kitahara, Fumiaki; Sato, Tadashi [University of Yamanashi, First Department of Internal Medicine, Chuo-shi, Yamanashi (Japan); Itakura, Jun; Fujii, Hideki [University of Yamanashi, First Department of Surgery, Chuo-shi, Yamanashi (Japan)

    2007-09-15

    We propose the hypothesis that the enlargement of the common bile duct (CBD) or gallbladder (GB) that is occasionally demonstrated on magnetic resonance cholangiopancreatography (MRCP) after secretin stimulation is caused by pancreatobiliary reflux. Recently, occult pancreatobiliary reflux (OPR) has been demonstrated in patients without morphological pancreatobiliary maljunction (MPBM). The aim of this study was to evaluate the efficacy of secretin-stimulating MRCP (SMRCP) in the diagnosis of pancreatobiliary reflux. The study included 14 patients with MPBM and 32 patients with a normal pancreatobiliary junction. OPR was evaluated by bile collection and diagnosed in seven of the 32 patients. All the patients underwent SMRCP; the related findings were considered positive when enlargement of the CBD or GB was observed. Positive findings on SMRCP were observed in all MPBM patients. In the patients with normal pancreatobiliary junction, there was significant difference between the mean amylase levels in the patients with positive and negative SMRCP findings (mean, 4,755.7 and 29.7 IU/l). The sensitivity and specificity of SMRCP for diagnosing OPR was 85.7% and 68.0%, respectively. SMRCP provides a non invasive method for excluding PBR and can identify patients who could benefit from bile duct sampling to diagnose OPR. (orig.)

  17. Lichtheim’s Golden shot

    NARCIS (Netherlands)

    Eling, P.A.T.M.

    2011-01-01

    Lichtheim belongs to the ranks of most famous aphasiologists, in particular because of a diagram often referred to as ‘Lichtheim’s House’. His single paper on aphasia has drawn the attention of the aphasiological community for many years and may be considered a golden shot. But it became, to

  18. Magnetic resonance cholangiographic (MRCP) features of ischemic-type biliary lesions (ITBL). A case-control study; Magnetresonanz-Cholangiografie (MRCP) bei Patienten mit Ischemic-Type Biliary Lesions (ITBL). Eine Fall-Kontroll-Studie

    Energy Technology Data Exchange (ETDEWEB)

    Collettini, F.; Kroencke, T.J.; Renz, D.M.; Bucourt, M. de; Poellinger, A. [Charite, Berlin (Germany). Klinik fuer Radiologie; Heidenhain, C.; Neuhaus, P. [Charite, Berlin (Germany). Klinik fuer Allgemein-, Visceral- und Transplantationschirurgie CVK

    2011-08-15

    Purpose: To evaluate the spectrum of MR cholangiography (MRCP) features of ischemic-type biliary lesions (ITBL) after orthotopic liver transplantation (OLT). Materials and Methods: 30 patients (16 m, 14 f) with an average age of 52 years (9 - 69 y) were examined in two 1.5 MR units using breath-hold 2D-SS-FSE-sequences and 3D-MRCP sequences. 20 of the 30 patients had an established ITBL, and the remaining 10 patients were post-OLT controls. MRCPs were evaluated independently by two experienced radiologists that were blinded to the clinical history as well as the results of other imaging modalities. All images were analyzed for the presence of 16 different pathological features. Differences between ITBL patients and controls were analyzed using the Mann-Whitney-U Test. Inter-rater variability was tested using the Cohen's Kappa test. Results: Abnormal findings of bile ducts were seen in all patients. The most common findings were (in percentage for reader 1/2) intrahepatic bile duct dilatation (95 %/95 %) and extrahepatic bile duct stenoses (95 %/85 %), followed by intrahepatic main duct stenoses (90 %/95 %) and segmental duct stenoses (85 %/85 %). Differences between ITBL patients and controls were significant for most of the analyzed features (Mann-Whitney-U test, p < 0.05). For 12 of 16 features, there was substantial or almost perfect agreement (K = 0.61 - 1.00), for 2 of 16 features moderate agreement (K = 0.41- 0.60) and for 2 of 16 features fair agreement (K < 0.40). Conclusion: In patients with ITBL, MR cholangiography reveals characteristic features that may allow differentiation from other biliary complications after liver transplantation. (orig.)

  19. Assembly procedure for Shot Loading Platform

    International Nuclear Information System (INIS)

    Routh, R.D.

    1995-01-01

    This supporting document describes the assembly procedure for the Shot Loading Platform. The Shot Loading Platform is used by multiple equipment removal projects to load shielding shot in the annular spaces of the equipment storage containers. The platform height is adjustable to accommodate different sizes of storage containers and transport assemblies

  20. Shot Automation for the National Ignition Facility

    International Nuclear Information System (INIS)

    Lagin, L J; Bettenhausen, R C; Beeler, R G; Bowers, G A; Carey, R.; Casavant, D.D.; Cline, B.D.; Demaret, R.D.; Domyancic, D.M.; Elko, S.D.; Fisher, J.M.; Hermann, M.R.; Krammen, J.E.; Kohut, T.R.; Marshall, C.D.; Mathisen, D.G.; Ludwigsen, A.P.; Patterson, Jr. R.W.; Sanchez, R.J.; Stout, E.A.; Van Arsdall, P.J.; Van Wonterghem, B.M.

    2005-01-01

    A shot automation framework has been developed and deployed during the past year to automate shots performed on the National Ignition Facility (NIF) using the Integrated Computer Control System This framework automates a 4-8 hour shot sequence, that includes inputting shot goals from a physics model, set up of the laser and diagnostics, automatic alignment of laser beams and verification of status. This sequence consists of set of preparatory verification shots, leading to amplified system shots using a 4-minute countdown, triggering during the last 2 seconds using a high-precision timing system, followed by post-shot analysis and archiving. The framework provides for a flexible, model-based execution driven of scriptable automation called macro steps. The framework is driven by high-level shot director software that provides a restricted set of shot life cycle state transitions to 25 collaboration supervisors that automate 8-laser beams (bundles) and a common set of shared resources. Each collaboration supervisor commands approximately 10 subsystem shot supervisors that perform automated control and status verification. Collaboration supervisors translate shot life cycle state commands from the shot director into sequences of ''macro steps'' to be distributed to each of its shot supervisors. Each Shot supervisor maintains order of macro steps for each subsystem and supports collaboration between macro steps. They also manage failure, restarts and rejoining into the shot cycle (if necessary) and manage auto/manual macro step execution and collaborations between other collaboration supervisors. Shot supervisors execute macro step shot functions commanded by collaboration supervisors. Each macro step has database-driven verification phases and a scripted perform phase. This provides for a highly flexible methodology for performing a variety of NIF shot types. Database tables define the order of work and dependencies (workflow) of macro steps to be performed for a

  1. Magnetic resonance cholangiographic (MRCP) features of ischemic-type biliary lesions (ITBL). A case-control study

    International Nuclear Information System (INIS)

    Collettini, F.; Kroencke, T.J.; Renz, D.M.; Bucourt, M. de; Poellinger, A.; Heidenhain, C.; Neuhaus, P.

    2011-01-01

    Purpose: To evaluate the spectrum of MR cholangiography (MRCP) features of ischemic-type biliary lesions (ITBL) after orthotopic liver transplantation (OLT). Materials and Methods: 30 patients (16 m, 14 f) with an average age of 52 years (9 - 69 y) were examined in two 1.5 MR units using breath-hold 2D-SS-FSE-sequences and 3D-MRCP sequences. 20 of the 30 patients had an established ITBL, and the remaining 10 patients were post-OLT controls. MRCPs were evaluated independently by two experienced radiologists that were blinded to the clinical history as well as the results of other imaging modalities. All images were analyzed for the presence of 16 different pathological features. Differences between ITBL patients and controls were analyzed using the Mann-Whitney-U Test. Inter-rater variability was tested using the Cohen's Kappa test. Results: Abnormal findings of bile ducts were seen in all patients. The most common findings were (in percentage for reader 1/2) intrahepatic bile duct dilatation (95 %/95 %) and extrahepatic bile duct stenoses (95 %/85 %), followed by intrahepatic main duct stenoses (90 %/95 %) and segmental duct stenoses (85 %/85 %). Differences between ITBL patients and controls were significant for most of the analyzed features (Mann-Whitney-U test, p < 0.05). For 12 of 16 features, there was substantial or almost perfect agreement (K = 0.61 - 1.00), for 2 of 16 features moderate agreement (K = 0.41- 0.60) and for 2 of 16 features fair agreement (K < 0.40). Conclusion: In patients with ITBL, MR cholangiography reveals characteristic features that may allow differentiation from other biliary complications after liver transplantation. (orig.)

  2. Rotary peening with captive shot

    International Nuclear Information System (INIS)

    1998-02-01

    Roto Peen with captive shot removes coatings and surface contamination from concrete floors. The objective of treating radioactively contaminated concrete floors during the Deactivation and Decommissioning (D and D) process is to reduce the surface contamination levels to meet regulatory criteria for unrestricted use. The US Department of Energy (DOE) Chicago Operations office and DOE's Federal Energy Technology Center (FETC) jointly sponsored a Large-Scale Demonstration Project (LSDP) at the Chicago Pile-5 Research Reactor (CP-5) at Argonne National Laboratory-East (ANL). The objective of the LSDP is to demonstrate potentially beneficial D and D technologies in comparison with current baseline technologies. As part of the LSDP, roto Peen with captive shot was demonstrated March 17--20, 1997, to treat a 20 x 25 ft area of radioactively contaminated concrete floor on the service level of the CP-5 building

  3. The Problem of Shot Selection in Basketball

    Science.gov (United States)

    Skinner, Brian

    2012-01-01

    In basketball, every time the offense produces a shot opportunity the player with the ball must decide whether the shot is worth taking. In this article, I explore the question of when a team should shoot and when they should pass up the shot by considering a simple theoretical model of the shot selection process, in which the quality of shot opportunities generated by the offense is assumed to fall randomly within a uniform distribution. Within this model I derive an answer to the question “how likely must the shot be to go in before the player should take it?” and I show that this lower cutoff for shot quality depends crucially on the number of shot opportunities remaining (say, before the shot clock expires), with larger demanding that only higher-quality shots should be taken. The function is also derived in the presence of a finite turnover rate and used to predict the shooting rate of an optimal-shooting team as a function of time. The theoretical prediction for the optimal shooting rate is compared to data from the National Basketball Association (NBA). The comparison highlights some limitations of the theoretical model, while also suggesting that NBA teams may be overly reluctant to shoot the ball early in the shot clock. PMID:22295109

  4. The problem of shot selection in basketball.

    Directory of Open Access Journals (Sweden)

    Brian Skinner

    Full Text Available In basketball, every time the offense produces a shot opportunity the player with the ball must decide whether the shot is worth taking. In this article, I explore the question of when a team should shoot and when they should pass up the shot by considering a simple theoretical model of the shot selection process, in which the quality of shot opportunities generated by the offense is assumed to fall randomly within a uniform distribution. Within this model I derive an answer to the question "how likely must the shot be to go in before the player should take it?" and I show that this lower cutoff for shot quality f depends crucially on the number n of shot opportunities remaining (say, before the shot clock expires, with larger n demanding that only higher-quality shots should be taken. The function f(n is also derived in the presence of a finite turnover rate and used to predict the shooting rate of an optimal-shooting team as a function of time. The theoretical prediction for the optimal shooting rate is compared to data from the National Basketball Association (NBA. The comparison highlights some limitations of the theoretical model, while also suggesting that NBA teams may be overly reluctant to shoot the ball early in the shot clock.

  5. The problem of shot selection in basketball.

    Science.gov (United States)

    Skinner, Brian

    2012-01-01

    In basketball, every time the offense produces a shot opportunity the player with the ball must decide whether the shot is worth taking. In this article, I explore the question of when a team should shoot and when they should pass up the shot by considering a simple theoretical model of the shot selection process, in which the quality of shot opportunities generated by the offense is assumed to fall randomly within a uniform distribution. Within this model I derive an answer to the question "how likely must the shot be to go in before the player should take it?" and I show that this lower cutoff for shot quality f depends crucially on the number n of shot opportunities remaining (say, before the shot clock expires), with larger n demanding that only higher-quality shots should be taken. The function f(n) is also derived in the presence of a finite turnover rate and used to predict the shooting rate of an optimal-shooting team as a function of time. The theoretical prediction for the optimal shooting rate is compared to data from the National Basketball Association (NBA). The comparison highlights some limitations of the theoretical model, while also suggesting that NBA teams may be overly reluctant to shoot the ball early in the shot clock.

  6. Sounding out the logo shot

    OpenAIRE

    Nicolai Jørgensgaard Graakjær

    2013-01-01

    This article focuses on how sound in combination with visuals (i.e. ‘branding by’) may possibly affect the signifying potentials (i.e. ‘branding effect’) of products and corporate brands (i.e. ‘branding of’) during logo shots in television commercials (i.e. ‘branding through’). This particular focus adds both to the understanding of sound in television commercials and to the understanding of sound brands. The article firstly presents a typology of sounds. Secondly, this typology is applied...

  7. Shot peening: theory applications and recent development

    International Nuclear Information System (INIS)

    Zaid, A.I.O.

    1999-01-01

    Shot peening is a surface treatment process by which the surface of an elastic-plastic target material is subjected to multiple impact by spherical shots made of glass or hard steel in a defined and controlled manner. The multiple impact produces a dynamic compressive stress at the surface of the target, thereby effectively improving its mechanical behavior and eliminates cracks and imperfections hence improving the fatigue life and strength. In this paper, the theory and practice of the shot peening process are reviewed. The main parameters involved in the process and their effects on shot peening are presented and discussed which include: shot material, size and geometry, shot pressure and shot velocity, projection angle, exposure time, table rotational speed, standoff distance coverage, saturation and peening intensity. Furthermore, the effect of shot peening on fatigue life and fatigue strength of ferrous and non-ferrous materials together with other different industrial applications of the process are given. Recent developments in utilizing the shot peening process with welded parts and hard chromium plating aiming at improvement of their fatigue strength and their resistance to stress corrosion cracking are also presented and discussed. Finally, future development of the process are outlined and discussed. (author)

  8. Basketball Shot Types and Shot Success in Different Levels of Competitive Basketball

    OpenAIRE

    Er?ulj, Frane; ?trumbelj, Erik

    2015-01-01

    The purpose of our research was to investigate the relative frequencies of different types of basketball shots (above head, hook shot, layup, dunk, tip-in), some details about their technical execution (one-legged, two-legged, drive, cut, …), and shot success in different levels of basketball competitions. We analysed video footage and categorized 5024 basketball shots from 40 basketball games and 5 different levels of competitive basketball (National Basketball Association (NBA), Euroleague,...

  9. SunShot Initiative Portfolio Book 2014

    Energy Technology Data Exchange (ETDEWEB)

    Solar Energy Technologies Office

    2014-05-01

    The 2014 SunShot Initiative Portfolio Book outlines the progress towards the goals outlined in the SunShot Vision Study. Contents include overviews of each of SunShot’s five subprogram areas, as well as a description of every active project in the SunShot’s project portfolio as of May 2014.

  10. A review on the basketball jump shot.

    Science.gov (United States)

    Okazaki, Victor H A; Rodacki, André L F; Satern, Miriam N

    2015-06-01

    The ability to shoot an effective jump shot in the sport of basketball is critical to a player's success. In an attempt to better understand the aspects related to expert performance, researchers have investigated successful free throws and jump shots of various basketball players and identified movement variables that contribute to their success. The purpose of this study was to complete a systematic review of the scientific literature on the basketball free throw and jump shot for the purpose of revealing the critical components of shooting that coaches, teachers, and players should focus on when teaching, learning, practising, and performing a jump shot. The results of this review are presented in three sections: (a) variables that affect ball trajectory, (b) phases of the jump shot, and (c) additional variables that influence shooting.

  11. Hepatitis A and the Vaccine (Shot) to Prevent It

    Science.gov (United States)

    ... Resources Maternal Immunization Resources Related Links Vaccines & Immunizations Hepatitis A and the Vaccine (Shot) to Prevent It ... the vaccine. Why should my child get the hepatitis A shot? The hepatitis A shot: Protects your ...

  12. MRI and MRCP of chronic pancreatitis. 1: technique and methods; La valutazione delle pancreatiti croniche con Risonanza Magnetica e colangiopancreatografia con Risonanza Magnetica. Prima parte: aspetti tecnico-metodologici

    Energy Technology Data Exchange (ETDEWEB)

    Laghi, A.; Pavone, P.; Catalano, C.; Panebianco, V.; Luccichenti, G.; Fabiano, S.; Passariello, R. [Rome Univ. La Sapienza, Rome (Italy). Ist. di Radiologia

    1999-10-01

    Until recently, MR examinations of the pancreas were limited by motion artifacts, vascular pulsatility and poor spatial resolution. Today, new techniques have been developed, which allow to overcome these problems and provide additional information such as selective images of biliary and pancreatic ducts and vascular structures. As a complement to baseline sequences, MR cholangiopancreatography images can be acquired, possibly integrated by functional examination after secretin administration. Finally, contrast-enhanced MR angiography opens new perspectives for vascular studies, particularly for the locoregional staging of pancreatic cancer. [Italian] Lo studio del pancreas con risonanza magnetica e' stato fino a pochi anni fa limitato dagli artefatti da movimento, da pulsatilita' vascolare e dalla ridotta risoluzione spaziale. Recentemente sono state sviluppate nuove tecniche che consentono da un lato di risolvere tali problemi e dall'altro di fornire informazioni aggiuntive, quali immagini selettive delle vie biliari e del dotto pancreatico e delle strutture vascolari. Come completamento all'esame di base si possono ottenere immagini di colangiopancreatografia con RM, eventualmente integrate da prove funzionali, rappresentate dall'iniezione di secretina. Infine, le nuove tecniche di angiografia con RM con mdc, nelle quali si effettua un'acquisizione durante la prima fase di passaggio arterioso o venoso dopo introduzione rapida del mdc a livello di una vena periferica, aprono nuove prospettive per lo studio vascolare, in particolare nella stadiazione loco-regionale dei processi neoplastici.

  13. 78 FR 65573 - Migratory Bird Hunting; Application for Approval of Copper-Clad Iron Shot and Fluoropolymer Shot...

    Science.gov (United States)

    2013-11-01

    ... shot, causing sediment/soil and water contamination and the direct ingestion of shot by aquatic and.... Shot[supreg]. * Coatings of copper, nickel, tin, zinc, zinc chloride, zinc chrome, and fluoropolymers...

  14. Basketball shot types and shot success in different levels of competitive basketball.

    Directory of Open Access Journals (Sweden)

    Frane Erčulj

    Full Text Available The purpose of our research was to investigate the relative frequencies of different types of basketball shots (above head, hook shot, layup, dunk, tip-in, some details about their technical execution (one-legged, two-legged, drive, cut, …, and shot success in different levels of basketball competitions. We analysed video footage and categorized 5024 basketball shots from 40 basketball games and 5 different levels of competitive basketball (National Basketball Association (NBA, Euroleague, Slovenian 1st Division, and two Youth basketball competitions. Statistical analysis with hierarchical multinomial logistic regression models reveals that there are substantial differences between competitions. However, most differences decrease or disappear entirely after we adjust for differences in situations that arise in different competitions (shot location, player type, and attacks in transition. Differences after adjustment are mostly between the Senior and Youth competitions: more shots executed jumping or standing on one leg, more uncategorised shot types, and more dribbling or cutting to the basket in the Youth competitions, which can all be attributed to lesser technical and physical ability of developing basketball players. The two discernible differences within the Senior competitions are that, in the NBA, dunks are more frequent and hook shots are less frequent compared to European basketball, which can be attributed to better athleticism of NBA players. The effect situational variables have on shot types and shot success are found to be very similar for all competitions.

  15. Basketball shot types and shot success in different levels of competitive basketball.

    Science.gov (United States)

    Erčulj, Frane; Štrumbelj, Erik

    2015-01-01

    The purpose of our research was to investigate the relative frequencies of different types of basketball shots (above head, hook shot, layup, dunk, tip-in), some details about their technical execution (one-legged, two-legged, drive, cut, …), and shot success in different levels of basketball competitions. We analysed video footage and categorized 5024 basketball shots from 40 basketball games and 5 different levels of competitive basketball (National Basketball Association (NBA), Euroleague, Slovenian 1st Division, and two Youth basketball competitions). Statistical analysis with hierarchical multinomial logistic regression models reveals that there are substantial differences between competitions. However, most differences decrease or disappear entirely after we adjust for differences in situations that arise in different competitions (shot location, player type, and attacks in transition). Differences after adjustment are mostly between the Senior and Youth competitions: more shots executed jumping or standing on one leg, more uncategorised shot types, and more dribbling or cutting to the basket in the Youth competitions, which can all be attributed to lesser technical and physical ability of developing basketball players. The two discernible differences within the Senior competitions are that, in the NBA, dunks are more frequent and hook shots are less frequent compared to European basketball, which can be attributed to better athleticism of NBA players. The effect situational variables have on shot types and shot success are found to be very similar for all competitions.

  16. Geotomography using refraction fan shots

    Science.gov (United States)

    Pavlis, Gary L.

    1986-05-01

    This paper introduces a new method for imaging lateral variations in the seismic velocity structure of the earth. The discussion is centered around the geometry of a pilot experiment conducted in Salt Creek valley near Bloomington, Indiana, but the methodology is more general in scope. In the pilot experiment, 24 explosions were fired at equal intervals around a circular area 190 m in diameter and recorded by geophones positioned diametrically opposite the source. Travel time residuals for the fan shots are inverted to estimate lateral velocity variations in a two-dimensional, bowl-shaped image reconstruction region under the circular array. A simple damped least squares inversion worked poorly when delay times were included as additional free parameters in the solution. A parameter separation procedure was more successful. The value of these data in determining structure was analyzed using synthetic data and resolving power calculations. Structure could be determined to high accuracy with little distortion in the center of the circular region where rays crossed from all directions, but results were comparatively poor near the fringes of the region where angular coverage was more limited. Inversion of the Salt Creek data indicates the observed variations in the residuals can be almost completely accounted for by variations in the weathered layer. The refractor velocity is nearly constant to a precision of 0.005 s/km, but there is a suggestion of a slight velocity decrease in the refractor at higher elevations above the water table.

  17. Evaluation of pancreatic exocrine insufficiency by cine-dynamic MRCP using spatially selective inversion-recovery (IR) pulse: Correlation with severity of chronic pancreatitis based on morphological changes of pancreatic duct.

    Science.gov (United States)

    Yasokawa, Kazuya; Ito, Katsuyoshi; Kanki, Akihiko; Yamamoto, Akira; Torigoe, Teruyuki; Sato, Tomohiro; Tamada, Tsutomu

    2018-05-01

    To evaluate the correlation between the pancreatic exocrine insufficiency estimated by cine-dynamic MRCP using spatially selective IR pulse and the severity stages (modified Cambridge classification) based on morphological changes of the pancreatic duct in patients with suspected chronic pancreatitis. Thirty-nine patients with suspected chronic pancreatitis underwent cine-dynamic MRCP with a spatially selective IR pulse. The secretion grading score (5-point scale) based on the moving distance of pancreatic juice inflow on cine-dynamic MRCP was assessed, and compared with the stage of the severity of chronic pancreatitis based on morphological changes of pancreatic duct. The stage of the severity of chronic pancreatitis based on morphological changes had significant negative correlations with the secretion grade (r=-0.698, P0.70 in 2 (33%) of 6 patients showing normal pancreatic exocrine function. It should be noted that the degree of morphological changes of pancreatic duct does not necessarily reflect the severity of pancreatic exocrine insufficiency at cine-dynamic MRCP in stage 2-3 chronic pancreatitis. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Comparison between MRI with MR cholangiopancreatography and endoscopic ultrasonography for differentiating malignant from benign mucinous neoplasms of the pancreas

    International Nuclear Information System (INIS)

    Hwang, Jiyoung; Hong, Seong Sook; Kim, Hyun-joo; Kim, Young Kon; Jeong, Woo Kyung; Min, Ji Hye

    2018-01-01

    To compare diagnostic performance of magnetic resonance imaging (MRI) and endoscopic ultrasonography (EUS) for differentiating malignant from benign intraductal papillary mucinous neoplasms (IPMN) and mucinous cystic neoplasms (MCN) of the pancreas. This retrospective study included 55 patients with 47 surgically confirmed IPMNs (12 malignant, 35 benign) and eight MCNs (two malignant, six benign) who underwent contrast-enhanced pancreas MRI and EUS. Contrast enhancement was not routinely used at EUS examination. Two observers independently evaluated the MRIs, and another reviewed EUS images. They recorded their confidence for malignancy with each imaging modality. We calculated diagnostic performance using the area under the receiver operating characteristic curves (A z ), and to determine the accuracy, sensitivity, specificity, and positive (PPV) and negative predictive (NPV) values. The A z values of MRI were higher than those of EUS (0.712 and 0.688 for MRI vs. 0.543 for EUS; p = 0.007). The diagnostic accuracies (74.5%), specificity (78.0% and 80.5%) and PPV (50.0%) of MRI in two observers were higher than those (56.4%, 58.5% and 29.2%, respectively) of EUS (p = 0.013-0.049). MRI showed better diagnostic performance than EUS for differentiating malignant from benign pancreatic IPMN and MCN. (orig.)

  19. Comparison between MRI with MR cholangiopancreatography and endoscopic ultrasonography for differentiating malignant from benign mucinous neoplasms of the pancreas

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jiyoung; Hong, Seong Sook; Kim, Hyun-joo [Seoul Hospital, Department of Radiology, Soonchunhyang University College of Medicine, Seoul (Korea, Republic of); Kim, Young Kon; Jeong, Woo Kyung [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Min, Ji Hye [Chungnam National University College of Medicine, Department of Radiology, Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2018-01-15

    To compare diagnostic performance of magnetic resonance imaging (MRI) and endoscopic ultrasonography (EUS) for differentiating malignant from benign intraductal papillary mucinous neoplasms (IPMN) and mucinous cystic neoplasms (MCN) of the pancreas. This retrospective study included 55 patients with 47 surgically confirmed IPMNs (12 malignant, 35 benign) and eight MCNs (two malignant, six benign) who underwent contrast-enhanced pancreas MRI and EUS. Contrast enhancement was not routinely used at EUS examination. Two observers independently evaluated the MRIs, and another reviewed EUS images. They recorded their confidence for malignancy with each imaging modality. We calculated diagnostic performance using the area under the receiver operating characteristic curves (A{sub z}), and to determine the accuracy, sensitivity, specificity, and positive (PPV) and negative predictive (NPV) values. The A{sub z} values of MRI were higher than those of EUS (0.712 and 0.688 for MRI vs. 0.543 for EUS; p = 0.007). The diagnostic accuracies (74.5%), specificity (78.0% and 80.5%) and PPV (50.0%) of MRI in two observers were higher than those (56.4%, 58.5% and 29.2%, respectively) of EUS (p = 0.013-0.049). MRI showed better diagnostic performance than EUS for differentiating malignant from benign pancreatic IPMN and MCN. (orig.)

  20. SunShot Initiative Fact Sheet

    Energy Technology Data Exchange (ETDEWEB)

    DOE Solar Energy Technologies Office

    2015-04-01

    The U.S. Department of Energy (DOE) SunShot Initiative is a collaborative national effort launched in 2011 that aggressively drives innovation to make solar energy fully cost competitive with traditional energy sources before the end of the decade. The SunShot fact sheet outlines goals and successes of the program as it works with private companies, universities, non-profit organizations, state and local governments, and national laboratories to drive down the cost of solar electricity to $0.06 per kilowatt-hour, without incentives, by the year 2020.

  1. Graduates of different UK medical schools show substantial differences in performance on MRCP(UK Part 1, Part 2 and PACES examinations

    Directory of Open Access Journals (Sweden)

    Mollon Jennifer

    2008-02-01

    Full Text Available Abstract Background The UK General Medical Council has emphasized the lack of evidence on whether graduates from different UK medical schools perform differently in their clinical careers. Here we assess the performance of UK graduates who have taken MRCP(UK Part 1 and Part 2, which are multiple-choice assessments, and PACES, an assessment using real and simulated patients of clinical examination skills and communication skills, and we explore the reasons for the differences between medical schools. Method We perform a retrospective analysis of the performance of 5827 doctors graduating in UK medical schools taking the Part 1, Part 2 or PACES for the first time between 2003/2 and 2005/3, and 22453 candidates taking Part 1 from 1989/1 to 2005/3. Results Graduates of UK medical schools performed differently in the MRCP(UK examination between 2003/2 and 2005/3. Part 1 and 2 performance of Oxford, Cambridge and Newcastle-upon-Tyne graduates was significantly better than average, and the performance of Liverpool, Dundee, Belfast and Aberdeen graduates was significantly worse than average. In the PACES (clinical examination, Oxford graduates performed significantly above average, and Dundee, Liverpool and London graduates significantly below average. About 60% of medical school variance was explained by differences in pre-admission qualifications, although the remaining variance was still significant, with graduates from Leicester, Oxford, Birmingham, Newcastle-upon-Tyne and London overperforming at Part 1, and graduates from Southampton, Dundee, Aberdeen, Liverpool and Belfast underperforming relative to pre-admission qualifications. The ranking of schools at Part 1 in 2003/2 to 2005/3 correlated 0.723, 0.654, 0.618 and 0.493 with performance in 1999–2001, 1996–1998, 1993–1995 and 1989–1992, respectively. Conclusion Candidates from different UK medical schools perform differently in all three parts of the MRCP(UK examination, with the

  2. Magnetic Resonance Cholangiopancreatography (MRCP)

    Science.gov (United States)

    ... radio waves and a computer to evaluate the liver, gallbladder, bile ducts, pancreas and pancreatic duct for disease. It is ... of the hepatobiliary and pancreatic systems, including the liver, gallbladder, bile ducts, pancreas and pancreatic duct . Magnetic resonance imaging (MRI) ...

  3. SnapShot: The Bacterial Cytoskeleton.

    Science.gov (United States)

    Fink, Gero; Szewczak-Harris, Andrzej; Löwe, Jan

    2016-07-14

    Most bacteria and archaea contain filamentous proteins and filament systems that are collectively known as the bacterial cytoskeleton, though not all of them are cytoskeletal, affect cell shape, or maintain intracellular organization. To view this SnapShot, open or download the PDF. Copyright © 2016. Published by Elsevier Inc.

  4. Shot noise of a quantum shuttle

    DEFF Research Database (Denmark)

    Novotny, Tomas; Donarini, Andrea; Flindt, Christian

    2004-01-01

    We formulate a theory for shot noise in quantum nanoelectromechanical systems. As a specific example, the theory is applied to a quantum shuttle, and the zero-frequency noise, measured by the Fano factor F, is computed. F reaches very low values (Fsimilar or equal to10(-2)) in the shuttling regim...

  5. Get Your Flu Shot!| NIH MedlinePlus the Magazine

    Science.gov (United States)

    ... of this page please turn Javascript on. Feature: Flu Shot Get Your Flu Shot! Past Issues / Winter 2011 Table of Contents ... failure, or lung disease "For the 2010–2011 flu season, the flu vaccine provides protection against the ...

  6. Research of shot noise based on realistic nano-MOSFETs

    Directory of Open Access Journals (Sweden)

    Xiaofei Jia

    2017-05-01

    Full Text Available Experimental measurements and simulation results have shown that the dominant noise source of current noise changes from thermal noise to shot noise with scaling of MOSFET, and shot noise were suppressed by Fermi and Coulomb interactions. In this paper, Shot noise test system is established, and experimental results proved that shot noise were suppressed, and the expressions of shot noise in realistic nano-MOSFETs are derived with considering Fermi effect, Coulomb interaction and the combination of the both co-existence, respectively. On this basis, the variation of shot noise with voltage, temperature and source-drain doping were researched. The results we obtained are consistent with those from experiments and the theoretically explanation is given. At the same time, the shot noise test system is suitable for traditional nanoscale electronic components; the shot noise model is suitable for nanoscale MOSFET.

  7. What You Can Expect with a Cortisone Shot

    Science.gov (United States)

    ... should avoid before your cortisone shot. What you can expect During the cortisone shot Your doctor might ... ll then be positioned so that your doctor can easily insert the needle. The area around the ...

  8. Shot-to-shot reproducibility of a self-magnetically insulated ion diode

    International Nuclear Information System (INIS)

    Pushkarev, A. I.; Isakova, Yu. I.; Khailov, I. P.

    2012-01-01

    In this paper we present the analysis of shot to shot reproducibility of the ion beam which is formed by a self-magnetically insulated ion diode with an explosive emission graphite cathode. The experiments were carried out with the TEMP-4M accelerator operating in double-pulse mode: the first pulse is of negative polarity (300–500 ns, 100–150 kV), and this is followed by a second pulse of positive polarity (150 ns, 250–300 kV). The ion current density was 10–70 A/cm 2 depending on the diode geometry. The beam was composed from carbon ions (80%–85%) and protons. It was found that shot to shot variation in the ion current density was about 35%–40%, whilst the diode voltage and current were comparatively stable with the variation limited to no more than 10%. It was shown that focusing of the ion beam can improve the stability of the ion current generation and reduces the variation to 18%–20%. In order to find out the reason for the shot-to-shot variation in ion current density we examined the statistical correlation between the current density of the accelerated beam and other measured characteristics of the diode, such as the accelerating voltage, total current, and first pulse duration. The correlation between the ion current density measured simultaneously at different positions within the cross-section of the beam was also investigated. It was shown that the shot-to-shot variation in ion current density is mainly attributed to the variation in the density of electrons diffusing from the drift region into the A-K gap.

  9. Shot-by-shot spectrum model for rod-pinch, pulsed radiography machines

    Directory of Open Access Journals (Sweden)

    Wm M. Wood

    2018-02-01

    Full Text Available A simplified model of bremsstrahlung production is developed for determining the x-ray spectrum output of a rod-pinch radiography machine, on a shot-by-shot basis, using the measured voltage, V(t, and current, I(t. The motivation for this model is the need for an agile means of providing shot-by-shot spectrum prediction, from a laptop or desktop computer, for quantitative radiographic analysis. Simplifying assumptions are discussed, and the model is applied to the Cygnus rod-pinch machine. Output is compared to wedge transmission data for a series of radiographs from shots with identical target objects. Resulting model enables variation of parameters in real time, thus allowing for rapid optimization of the model across many shots. “Goodness of fit” is compared with output from LSP Particle-In-Cell code, as well as the Monte Carlo Neutron Propagation with Xrays (“MCNPX” model codes, and is shown to provide an excellent predictive representation of the spectral output of the Cygnus machine. Improvements to the model, specifically for application to other geometries, are discussed.

  10. Shot-by-shot spectrum model for rod-pinch, pulsed radiography machines

    Science.gov (United States)

    Wood, Wm M.

    2018-02-01

    A simplified model of bremsstrahlung production is developed for determining the x-ray spectrum output of a rod-pinch radiography machine, on a shot-by-shot basis, using the measured voltage, V(t), and current, I(t). The motivation for this model is the need for an agile means of providing shot-by-shot spectrum prediction, from a laptop or desktop computer, for quantitative radiographic analysis. Simplifying assumptions are discussed, and the model is applied to the Cygnus rod-pinch machine. Output is compared to wedge transmission data for a series of radiographs from shots with identical target objects. Resulting model enables variation of parameters in real time, thus allowing for rapid optimization of the model across many shots. "Goodness of fit" is compared with output from LSP Particle-In-Cell code, as well as the Monte Carlo Neutron Propagation with Xrays ("MCNPX") model codes, and is shown to provide an excellent predictive representation of the spectral output of the Cygnus machine. Improvements to the model, specifically for application to other geometries, are discussed.

  11. Shot peening of doel 3 plant

    International Nuclear Information System (INIS)

    Slama, G.; Sort, M.

    1985-12-01

    The process implementation for DOEL consisted in: developing tooling and test procedures for an industrial application including ALARA considerations; qualifying process, tooling and procedures using representative conditions (full size mock-up, of steam generator channel head and associated working area); Establishing the reliability of tooling and procedures to comply permanently with the required criteria (chiefly Almen Intensity); and training and qualifying personnel. A variety of tests were performed by FRAMATOME and BELGATOM to qualify the process and characterize its effects on both inside and outside diameters of the tubes. These are: Mg Cl 2 ; 10% caustic tests at high temperature and pressure; tetrathionate; strain gauges and X rays stresses measurements; effects on precracked tubes; Leak tests after shot peening. The operation was performed at Doel in July 1985. Laboratory tests performed on mockups by FRAMATOME and BELGATOM could demonstrate that on tubes without cracks no difference was found between Eddy current signals from tubes shot-peened or not

  12. Shot peening speed measurements using lidar technology

    DEFF Research Database (Denmark)

    Angelou, Nikolas; Zhang, Xiaodan; Sjöholm, Mikael

    The shot peening technique is used for the surface modification of metallic components that are part of wind turbines, such as gears, bolts and blade coatings to prevent erosion. An important parameter of this technique is the dynamic energy of emitted shots. In this context the objective......, the risk of damaging the peening machine by installing an instrument inside the chamber during operation is eliminated by this approach. Laser anemometers are being researched and developed in the department of Wind Energy, mainly in the framework of the WindScanner.dk infrastructure project [1], but also...... validated and used in monitoring the wind conditions around wind turbines (wake and inflow), over complex terrain as well as offshore....

  13. Beauty and science in a shot

    Science.gov (United States)

    Ciceri, Piera

    2017-04-01

    Taking pictures has become a daily action for young. Photography is an essential component of many areas of science, has played a crucial role in the study of anatomy, botany, archeology, ... Still today it is a "scientific tool" in the school textbooks: pictures describe, make reality larger or smaller, faster or slower, show evidence and experimental results. But a photograph has the ability to move, engage and inspire viewers. That means that a photograph can build an emotional bridge between science and people. People and students can get closer to science through beautiful, evocative and expressive shot. In this project students are involved in taking pictures with a scientific and aesthetic content looking around, setting an experiment, watching nature, playing with light, point of wiew, colors and perspective. They have to write a short text and a title that explains the scientific content, why and how they have taken the picture. Both description and title should let increase curiosity, could looks fun or stress artistic aspects. Student show their shots in an official public event in Milan managed by a committee of science and photograph experts and in a local event to parents and local community. "Shots of science" is a project promoted by the italian national association "Scienza under 18", the Physic Department of "Università degli Studi di Milano" and the "Museo di fotografia contemporanea" of Cinisello Balsamo (MI) that help students in discussing about scientific and artistic aspects of their shots. This project contributes to develop digital skills (such as to manage digital images, to share documents, to learn about copyright and creative commons license), communication skills (such as to write a caption, public speaking, to use a picture to communicate), collaboration skills (such as to work with pairs, to respect scheduled times, to be positive in giving and taking into account suggestions) and artistic skills (to learn how to compose a good

  14. Empathy in One-Shot Prisoner Dilemma

    OpenAIRE

    Rossi, Giulia; Tcheukam, Alain; Tembine, Hamidou

    2017-01-01

    Strategic decision making involves affective and cognitive functions like reasoning, cognitive and emotional empathy which may be subject to age and gender differences. However, empathy-related changes in strategic decision-making and their relation to age, gender and neuropsychological functions have not been studied widely. In this article, we study a one-shot prisoner dilemma from a psychological game theory viewpoint. Forty seven participants (28 women and 19 men), aged 18 to 42 years, we...

  15. Centrifugal shot blasting. Innovative technology summary report

    International Nuclear Information System (INIS)

    1999-07-01

    At the US Department of Energy (DOE) Fernald Environmental Management Project (FEMP), the Facilities Closure and Demolition Projects Integrated Remedial Design/Remedial Action (RD/RA) work plan calls for the removal of one inch (1 in) depth of concrete surface in areas where contamination with technetium-99 has been identified. This report describes a comparative demonstration between two concrete removal technologies: an innovative system using Centrifugal Shot Blasting (CSB) and a modified baseline technology called a rotary drum planer

  16. Osseointegration improvement by shot peening in titanium dental implants

    International Nuclear Information System (INIS)

    Aparicio, C.; Gil, F.J.; Planell, J.A.; Padros, A.; Peraire, C.

    1998-01-01

    In order to optimize the implant-bone fixation, different shot peening treatments with different shot particles (TiO 2 , Al 2 O 3 ; SiC) have been made. The influence that each type of shot particle has in the bone colonization on the different treatment surfaces has been determined by means of osteoblast-like cells culture. Commercially pure titanium discs have been shot peened. Their qualitative and quantitative surface roughness have been characterized; as well as their surface contamination caused by the shot particles. Particle size has also been determined, before and after the treatment, in order to evaluate their breaking averages. Finally, a TiO 2 shot particles manufacture process by sintering has been developed. The manufacture has been necessary since this type of shot particles are not available in the market with the adequate size. (Author) 10 refs

  17. Surface severe plastic deformation of AISI 304 via conventional shot peening, severe shot peening and repeening

    Energy Technology Data Exchange (ETDEWEB)

    Unal, Okan, E-mail: unalokan78@gmail.com [Mechanical Engineering Department, Bartın University, Bartın 74100 (Turkey); Varol, Remzi [Mechanical Engineering Department, Suleyman Demirel University, Isparta 32200 (Turkey)

    2015-10-01

    Highlights: • CSP and SSP treatments transform austenite to metastable martensite structure. • Nanograin layer thickness after CSP and SSP is 8 μm and 22 μm, respectively. • Shot peening leads to carbon segregation from coarse to nano grain layer. • Repeening is an effective way to reduce surface roughness. - Abstract: Air blast conventional shot peening (CSP), severe shot peening (SSP) and repeening (RP) as a severe plastic deformation applications on AISI 304 austenitic stainless steel is addressed. Shot peened specimens are investigated based on optical, FESEM and digital microscope. The investigations present the austenite transformation to metastable martensite via mechanical twinning due to plastic deformation with high strain rates. It is found that SSP induces thicker nanograin layer with compared to CSP. In XRD studies, the austenite peaks broaden by means of severe shot peening and FWHM increase reveals the grain size reduction below 25 nm regimes on the surface. In EDAX line analysis of CSP specimen, carbon content increase has been detected from deformed layer through the nanocrystalline layer then the content reduces. The carbon segregation takes place due to the energy level distinction between dislocations and Fe−C bonds. 3d contour digital microscope studies and roughness investigations reveal that SSP has deleterious side effect on the surface roughness and surface flatness. However, RP is an effective way to reduce the surface roughness to reasonable values.

  18. SnapShot: Phosphoregulation of Mitosis.

    Science.gov (United States)

    Burgess, Andrew; Vuong, Jenny; Rogers, Samuel; Malumbres, Marcos; O'Donoghue, Seán I

    2017-06-15

    During mitosis, a cell divides its duplicated genome into two identical daughter cells. This process must occur without errors to prevent proliferative diseases (e.g., cancer). A key mechanism controlling mitosis is the precise timing of more than 32,000 phosphorylation and dephosphorylation events by a network of kinases and counterbalancing phosphatases. The identity, magnitude, and temporal regulation of these events have emerged recently, largely from advances in mass spectrometry. Here, we show phosphoevents currently believed to be key regulators of mitosis. For an animated version of this SnapShot, please see http://www.cell.com/cell/enhanced/odonoghue2. Copyright © 2017. Published by Elsevier Inc.

  19. Shuttlecock Velocity of a Badminton Drop Shot

    Directory of Open Access Journals (Sweden)

    Ampharin Ongvises

    2013-01-01

    Full Text Available In a badminton ‘drop shot’, the shuttlecock is struck by a non-rotating racquet at low speed. In this investigation, a shuttlecock was hit by a badminton racquet in a linear collision, simulating a drop shot. The collision was recorded with high-speed video and the velocities of the racquet and shuttlecock determined. The relationship between the impact velocity of the racquet and the velocity of the shuttlecock as it leaves the badminton racquet after collision was found to be proportional over the range tested.

  20. Shuttlecock Velocity of a Badminton Drop Shot

    Directory of Open Access Journals (Sweden)

    Ampharin Ongvises

    2013-12-01

    Full Text Available In a badminton ‘drop shot’, the shuttlecock is struck by a non-rotating racquet at low speed. In this investigation, a shuttlecock was hit by a badminton racquet in a linear collision, simulating a drop shot. The collision was recorded with high-speed video and the velocities of the racquet and shuttlecock determined. The relationship between the impact velocity of the racquet and the velocity of the shuttlecock as it leaves the badminton racquet after collision was found to be proportional over the range tested.

  1. Influence of Running on Pistol Shot Hit Patterns.

    Science.gov (United States)

    Kerkhoff, Wim; Bolck, Annabel; Mattijssen, Erwin J A T

    2016-01-01

    In shooting scene reconstructions, risk assessment of the situation can be important for the legal system. Shooting accuracy and precision, and thus risk assessment, might be correlated with the shooter's physical movement and experience. The hit patterns of inexperienced and experienced shooters, while shooting stationary (10 shots) and in running motion (10 shots) with a semi-automatic pistol, were compared visually (with confidence ellipses) and statistically. The results show a significant difference in precision (circumference of the hit patterns) between stationary shots and shots fired in motion for both inexperienced and experienced shooters. The decrease in precision for all shooters was significantly larger in the y-direction than in the x-direction. The precision of the experienced shooters is overall better than that of the inexperienced shooters. No significant change in accuracy (shift in the hit pattern center) between stationary shots and shots fired in motion can be seen for all shooters. © 2015 American Academy of Forensic Sciences.

  2. Concrete Cleaning, Inc. centrifugal shot blaster: Baseline report; Summary

    International Nuclear Information System (INIS)

    1997-01-01

    The centrifugal shot blaster is an electronically operated shot-blast machine that removes layer of concrete of varying depths. Hardened steel shot propelled at a high rate of speed abrades the surface of the concrete. The depth of material removed is determined by the rate of speed the machine is traveling and the volume of shot being fired into the blast chamber. The steel shot is reused until it is pulverized to dust, which is deposited in the waste container with the concrete being removed. Debris is continually vacuumed by a large dust collection system attached to the shot blaster. The safety and health evaluation during the human factors assessment focused on two main areas: noise and dust

  3. Removal of Retained Lead Shot Through Laparoscopic Appendectomy

    Science.gov (United States)

    Lloyd, D. M.

    2003-01-01

    We describe a patient presenting with lead shot in his appendix. A plain radiograph of his lumbar spine was performed for back pain, and an incidental finding of lead shot retained within the appendix was seen. Lead shot in the appendix is associated with appendicitis, and 2 cases have been reported of lead intoxication. We suggest that an elective laparoscopic appendectomy should be offered to patients as a possible management option. PMID:12856854

  4. [Contact shot from infantry weapons with a flash-suppressor].

    Science.gov (United States)

    Perdekamp, Markus Grosse; Braunwarth, Roland; Schmidt, Ulrike; Schmidt, Wolfgang; Pollak, Stefan

    2003-01-01

    The number of reports on contact shots from firearms with a flash suppressor attached to the muzzle is small. On the basis of a case report (suicidal shot to the forehead with a Kalschnikow AKMS 47 assault rifle) the morphological peculiarities (characteristics soot pattern, relatively small powder cavity and only minor skin tears in the presence of a bony support) are presented and the conclusions to be drawn from the findings regarding the flash-suppressor, the shot distance, the angle of the shot and the way of holding the weapon are discussed.

  5. Entrance, exit, and reentrance of one shot with a shotgun

    DEFF Research Database (Denmark)

    Gulmann, C; Hougen, H P

    1999-01-01

    The case being reported is one of a homicidal shotgun fatality with an unusual wound pattern. A 34-year-old man was shot at close range with a 12-gauge shotgun armed with No. 5 birdshot ammunition. The shot entered the left axillary region, exited through the left infraclavicular region, and ther......The case being reported is one of a homicidal shotgun fatality with an unusual wound pattern. A 34-year-old man was shot at close range with a 12-gauge shotgun armed with No. 5 birdshot ammunition. The shot entered the left axillary region, exited through the left infraclavicular region...

  6. Collider shot setup for Run 2 observations and suggestions

    International Nuclear Information System (INIS)

    Annala, J.; Joshel, B.

    1996-01-01

    This note is intended to provoke discussion on Collider Run II shot setup. We hope this is a start of activities that will converge on a functional description of what is needed for shot setups in Collider Run II. We will draw on observations of the present shot setup to raise questions and make suggestions for the next Collider run. It is assumed that the reader has some familiarity with the Collider operational issues. Shot setup is defined to be the time between the end of a store and the time the Main Control Room declares colliding beams. This is the time between Tevatron clock events SCE and SCB. This definition does not consider the time experiments use to turn on their detectors. This analysis was suggested by David Finley. The operational scenarios for Run II will require higher levels of reliability and speed for shot setup. See Appendix I and II. For example, we estimate that a loss of 3 pb -1 /week (with 8 hour stores) will occur if shot setups take 90 minutes instead of 30 minutes. In other words: If you do 12 shots for one week and accept an added delay of one minute in each shot, you will loose more than 60 nb -1 for that week alone (based on a normal shot setup of 30 minutes). These demands should lead us to be much more pedantic about all the factors that affect shot setups. Shot setup will be viewed as a distinct process that is composed of several inter- dependent 'components': procedures, hardware, controls, and sociology. These components don't directly align with the different Accelerator Division departments, but are topical groupings of the needed accelerator functions. Defining these components, and categorizing our suggestions within them, are part of the goal of this document. Of course, some suggestions span several of these components

  7. Multi-shot type pellet injection device

    International Nuclear Information System (INIS)

    Onozuka, Masaki; Uchikawa, Takashi; Kuribayashi, Shitomi.

    1988-01-01

    Purpose: To inject pellets at high speed without melting or sublimating not-injected pellets even at a long pellet injection interval. Constitution: In the conventional multi-shot pellet injection device, the pellet injection interval is set depending on the plasma retention time. However, as the pellet injection interval is increased, not-injected pellets are melted or sublimated due to the introduced heat of acceleration gases supplied from an acceleration gas introduction pipe to give an effect on the dimensional shape of the pellets. In view of the above, a plurality of pellet forming and injection portions each comprising a carrier, an injection pipe and a holder are disposed independently of each other and pellets are formed and injected independently to thereby prevent the thermal effects of the acceleration gases. (Kamimura, M.)

  8. Multi-shot type pellet injection device

    Energy Technology Data Exchange (ETDEWEB)

    Onozuka, Masaki; Uchikawa, Takashi; Kuribayashi, Shitomi.

    1988-07-27

    Purpose: To inject pellets at high speed without melting or sublimating not-injected pellets even at a long pellet injection interval. Constitution: In the conventional multi-shot pellet injection device, the pellet injection interval is set depending on the plasma retention time. However, as the pellet injection interval is increased, not-injected pellets are melted or sublimated due to the introduced heat of acceleration gases supplied from an acceleration gas introduction pipe to give an effect on the dimensional shape of the pellets. In view of the above, a plurality of pellet forming and injection portions each comprising a carrier, an injection pipe and a holder are disposed independently of each other and pellets are formed and injected independently to thereby prevent the thermal effects of the acceleration gases. (Kamimura, M.).

  9. Mumps and the Vaccine (Shot) to Prevent It

    Science.gov (United States)

    ... as measles and rubella. Prevents your child from getting a fever and swollen glands under the ears or jaw from mumps. Keeps your child from missing school or child care (and keeps you from missing work to care for your sick child). Is the MMR shot safe? Yes. The MMR shot is very safe, and it ...

  10. Toxicity of Lead and Proposed Substitute Shot to Mallards

    Science.gov (United States)

    Longcore, J.R.; Andrews, R.; Locke, L.N.; Bagley, George E.; Young, L.T.

    1974-01-01

    Poisoning of North American waterfowl resulting from the ingestion of lead shot by ducks, geese, and swans causes an estimated annual mortality of 2 to 3% of the population (Bellrose 1959). To alleviate this problem the search for a suitable substitute for lead has been underway since the early 1950's. Proposed substitutes for lead shot were evaluated in a series of acute toxicity tests with pen-reared mallards (Anas platyrhynchos). Most candidate materials were as toxic to ducks as commercial lead shot. Coating or alloying lead with other metals only delayed mortality among dosed ducks. The reputedly 'disintegrable' lead shot with the water-soluble binder and the lead containing biochemical additives were also as toxic to mallards as the commercial lead shot. Mortality was not significantly different among lead-dosed adult or first-year hen and drake pen-reared mallards; lead-dosed adult, wild mallards of both sexes; and lead-dosed adult, male black ducks (Anas rubripes). The ingestion of one lead shot, size 4, by each of 80 pen-reared mallards caused an average 19% mortality. The presence and type of grit in the gizzard had a measurable effect on erosion of ingested shot and on shot retention among dosed mallards. Significantly fewer lead-dosed ducks died when fed crushed oystershell grit than when fed either quartz grit or no grit.

  11. Single-shot fluctuations in waveguided high-harmonic generation

    NARCIS (Netherlands)

    Goh, S.J.; Tao, Y.; van der Slot, Petrus J.M.; Bastiaens, Hubertus M.J.; Herek, Jennifer Lynn; Biedron, S.G.; Danailov, M.B.; Milton, S.V.; Boller, Klaus J.

    2015-01-01

    For exploring the application potential of coherent soft x-ray (SXR) and extreme ultraviolet radiation (XUV) provided by high-harmonic generation, it is important to characterize the central output parameters. Of specific importance are pulse-to-pulse (shot-to-shot) fluctuations of the high-harmonic

  12. Equilibrium and shot noise in mesoscopic systems

    Energy Technology Data Exchange (ETDEWEB)

    Martin, T.

    1994-10-01

    Within the last decade, there has been a resurgence of interest in the study of noise in Mesoscopic devices, both experimentally and theoretically. Noise in solid state devices can have different origins: there is 1/f noise, which is believed to arise from fluctuations in the resistance of the sample due to the motion of impurities. On top of this contribution is a frequency independent component associated with the stochastic nature of electron transport, which will be the focus of this paper. If the sample considered is small enough that dephasing and inelastic effects can be neglected, equilibrium (thermal) and excess noise can be completely described in terms of the elastic scattering properties of the sample. As mentioned above, noise arises as a consequence of random processes governing the transport of electrons. Here, there are two sources of randomness: first, electrons incident on the sample occupy a given energy state with a probability given by the Fermi-Dirac distribution function. Secondly, electrons can be transmitted across the sample or reflected in the same reservoir where they came from with a probability given by the quantum mechanical transmission/reflection coefficients. Equilibrium noise refers to the case where no bias voltage is applied between the leads connected to the sample, where thermal agitation alone allows the electrons close to the Fermi level to tunnel through the sample. In general, equilibrium noise is related to the conductance of the sample via the Johnson-Nyquist formula. In the presence of a bias, in the classical regime, one expects to recover the full shot noise < {Delta}{sup 2}I >= 2I{Delta}{mu} as was observed a long time ago in vacuum diodes. In the Mesoscopic regime, however, excess noise is reduced below the shot noise level. The author introduces a more intuitive picture, where the current passing through the device is a superposition of pulses, or electron wave packets, which can be transmitted or reflected.

  13. A shot parameter specification subsystem for automated control of PBFA II accelerator shots

    International Nuclear Information System (INIS)

    Spiller, J.L.

    1987-01-01

    The author reports on the shot parameter specification subsystem (SPSS), an integral part of the automatic control system developed for the Particle Beam Fusion Accelerator II (PBFA II). This system has been designed to fully utilize the accelerator by tailoring shot parameters to the needs of the experimenters. The SPSS is the key to this flexibility. Automatic systems will be required on many pulsed power machines for the fastest turnaround, the highest reliability, and most cost effective operation. These systems will require the flexibility and the ease of use that is part of the SPSS. The author discusses how the PBFA II control system has proved to be an effective modular system, flexible enough to meet the demands of both the fast track construction of PBFA II and the control needs of Hermes III. This system is expected to meet the demands of most future machine changes

  14. Bond strength investigation of two shot moulded polymer

    DEFF Research Database (Denmark)

    Islam, Mohammad Aminul

    This report on the project “Bond strength investigation of two shot moulded polymers” has been submitted for fulfilling the requirements for the course “Experimental Plastic Technology – 42234” at IPL-DTU. Two shot moulding is a classic manufacturing process to combine two different polymers...... in a single product and it is getting more and more importance day by day. One of the biggest challenges of two shot moulding is to achieve a reasonably good bonding between two polymers. The purpose of this project is to investigate the effects of different process, material and machine parameters...... on the bond strength of two shot moulded polymers. For the experiments two engineering polymers (PS and ABS) were used. After all the experimental work, several parameters were found which could effectively control the bond strength of two shot moulded polymers. This report also presents different aspects...

  15. Catastrophe Insurance Modeled by Shot-Noise Processes

    Directory of Open Access Journals (Sweden)

    Thorsten Schmidt

    2014-02-01

    Full Text Available Shot-noise processes generalize compound Poisson processes in the following way: a jump (the shot is followed by a decline (noise. This constitutes a useful model for insurance claims in many circumstances; claims due to natural disasters or self-exciting processes exhibit similar features. We give a general account of shot-noise processes with time-inhomogeneous drivers inspired by recent results in credit risk. Moreover, we derive a number of useful results for modeling and pricing with shot-noise processes. Besides this, we obtain some highly tractable examples and constitute a useful modeling tool for dynamic claims processes. The results can in particular be used for pricing Catastrophe Bonds (CAT bonds, a traded risk-linked security. Additionally, current results regarding the estimation of shot-noise processes are reviewed.

  16. Investigation of kinematics of knuckling shot in soccer

    Science.gov (United States)

    Asai, T.; Hong, S.

    2017-02-01

    In this study, we use four high-speed video cameras to investigate the swing characteristics of the kicking leg while delivering the knuckling shot in soccer. We attempt to elucidate the impact process of the kicking foot at the instant of its impact with the ball and the technical mechanisms of the knuckling shot via comparison of its curved motion with that of the straight and curved shots. Two high-speed cameras (Fastcam, Photron Inc., Tokyo, Japan; 1000 fps, 1024 × 1024 pixels) are set up 2 m away from the site of impact with a line of sight perpendicular to the kicking-leg side. In addition, two semi-high-speed cameras (EX-F1, Casio Computer Co., Ltd., Tokyo, Japan; 300 fps; 720 × 480 pixels) are positioned, one at the rear and the other on the kicking-leg side, to capture the kicking motion. We observe that the ankle joint at impact in the knuckling shot flexes in an approximate L-shape in a manner similar to the joint flexing for the curve shot. The hip's external rotation torque in the knuckling shot is greater than those of other shots, which suggests the tendency of the kicker to push the heel forward and impact with the inside of the foot. The angle of attack in the knuckling shot is smaller than that in other shots, and we speculate that this small attack angle is a factor in soccer kicks which generate shots with smaller rotational frequencies of the ball.

  17. Orchestrating Shots for the National Ignition Facility (NIF)

    International Nuclear Information System (INIS)

    Mathisen, D G; Bettenhausen, R C; Beeler, R G; Bowers, G A; Carey, R W; Casavant, D D; Cline, B D; Demaret, R D; Domyancic, D M; Elko, S D; Fisher, J M; Krammen, J E; Lagin, L J; Ludwigsen, A P; Patterson, R W; Sanchez, R J; Stout, E A

    2005-01-01

    The National Ignition Facility (NIF), currently under construction at the Lawrence Livermore National Laboratory, is a stadium-sized facility containing a 192-beam, 1.8 Megajoule, 500-Terawatt, ultra-violet laser system together with a 10-meter diameter target chamber with room for nearly 100 experimental diagnostics. When completed, NIF will be the world's largest and most energetic laser experimental system, providing an international center to study inertial confinement fusion and physics of matter at extreme densities and pressures. The NIF is operated by the Integrated Computer Control System (ICCS), which is a layered architecture of over 700 lower-level front-end processors attached to nearly 60,000 control points and coordinated by higher-level supervisory subsystems in the main control room. A shot automation framework has been developed and deployed during the past year to orchestrate and automate shots performed at the NIF using the ICCS. The Shot Automation framework is designed to automate 4-8 hour shot sequences, that includes deriving shot goals from an experiment definition, set up of the laser and diagnostics, automatic alignment of laser beams, and a countdown to charge and fire the lasers. These sequences consist of set of preparatory verification shots, leading to amplified system shots followed by post-shot analysis and archiving. The framework provides for a flexible, model-based work-flow execution, driven by scripted automation called macro steps. The shot director software is the orchestrating component of a very flexible automation layer which allows us to define, coordinate and reuse simpler automation sequences. This software provides a restricted set of shot life cycle state transitions to 26 collaboration supervisors that automate 8-laser beams (bundle) and a common set of shared resources. Each collaboration supervisor commands approximately 10 subsystem shot supervisors that perform automated control and status verification

  18. Resitting a high-stakes postgraduate medical examination on multiple occasions: nonlinear multilevel modelling of performance in the MRCP(UK examinations

    Directory of Open Access Journals (Sweden)

    McManus IC

    2012-06-01

    Full Text Available Abstract Background Failure rates in postgraduate examinations are often high and many candidates therefore retake examinations on several or even many times. Little, however, is known about how candidates perform across those multiple attempts. A key theoretical question to be resolved is whether candidates pass at a resit because they have got better, having acquired more knowledge or skills, or whether they have got lucky, chance helping them to get over the pass mark. In the UK, the issue of resits has become of particular interest since the General Medical Council issued a consultation and is considering limiting the number of attempts candidates may make at examinations. Methods Since 1999 the examination for Membership of the Royal Colleges of Physicians of the United Kingdom (MRCP(UK has imposed no limit on the number of attempts candidates can make at its Part 1, Part2 or PACES (Clinical examination. The present study examined the performance of candidates on the examinations from 2002/2003 to 2010, during which time the examination structure has been stable. Data were available for 70,856 attempts at Part 1 by 39,335 candidates, 37,654 attempts at Part 2 by 23,637 candidates and 40,303 attempts at PACES by 21,270 candidates, with the maximum number of attempts being 26, 21 and 14, respectively. The results were analyzed using multilevel modelling, fitting negative exponential growth curves to individual candidate performance. Results The number of candidates taking the assessment falls exponentially at each attempt. Performance improves across attempts, with evidence in the Part 1 examination that candidates are still improving up to the tenth attempt, with a similar improvement up to the fourth attempt in Part 2 and the sixth attempt at PACES. Random effects modelling shows that candidates begin at a starting level, with performance increasing by a smaller amount at each attempt, with evidence of a maximum, asymptotic level for

  19. Resitting a high-stakes postgraduate medical examination on multiple occasions: nonlinear multilevel modelling of performance in the MRCP(UK) examinations.

    Science.gov (United States)

    McManus, I C; Ludka, Katarzyna

    2012-06-14

    Failure rates in postgraduate examinations are often high and many candidates therefore retake examinations on several or even many times. Little, however, is known about how candidates perform across those multiple attempts. A key theoretical question to be resolved is whether candidates pass at a resit because they have got better, having acquired more knowledge or skills, or whether they have got lucky, chance helping them to get over the pass mark. In the UK, the issue of resits has become of particular interest since the General Medical Council issued a consultation and is considering limiting the number of attempts candidates may make at examinations. Since 1999 the examination for Membership of the Royal Colleges of Physicians of the United Kingdom (MRCP(UK)) has imposed no limit on the number of attempts candidates can make at its Part 1, Part 2 or PACES (Clinical) examination. The present study examined the performance of candidates on the examinations from 2002/2003 to 2010, during which time the examination structure has been stable. Data were available for 70,856 attempts at Part 1 by 39,335 candidates, 37,654 attempts at Part 2 by 23,637 candidates and 40,303 attempts at PACES by 21,270 candidates, with the maximum number of attempts being 26, 21 and 14, respectively. The results were analyzed using multilevel modelling, fitting negative exponential growth curves to individual candidate performance. The number of candidates taking the assessment falls exponentially at each attempt. Performance improves across attempts, with evidence in the Part 1 examination that candidates are still improving up to the tenth attempt, with a similar improvement up to the fourth attempt in Part 2 and the sixth attempt at PACES. Random effects modelling shows that candidates begin at a starting level, with performance increasing by a smaller amount at each attempt, with evidence of a maximum, asymptotic level for candidates, and candidates showing variation in starting

  20. The role of MRI in evaluation of acute pancreatitis

    International Nuclear Information System (INIS)

    Baba, Maiko; Munechika, Horotsugu

    2003-01-01

    The purpose of this study is to assess the role of MRI in acute pancreatitis. The findings of MPD (main pancreatic duct) and CBD (common bile duct) on MR cholangiopancreatography (MRCP) images were retrospectively reviewed in 60 patients with acute pancreatitis. The patients were divided into two groups; severe and mild pancreatitis, according to the criteria of Japanese group of investigation for pancreatic diseases. T2 weighed MR images were compared with contrast-enhanced CT images for evaluation of severity of the disease. MRCP images were also compared with endoscopic retrograde cholangiopancreatography (ERCP) images for evaluation of MPD and CBD. CBD was more clearly demonstrated by MRCP than MPD. Both MPD and CBD were more clearly seen in the mild group than in the severe group. A few false-negative cases were seen in MRCP. T2 weighed MR images were almost the same as contrast-enhanced CT images in diagnosis of acute pancreatitis. MRCP is useful for evaluation of CBD in severe cases and for evaluation of both CBD and MPD in mild cases of acute pancreatitis. The severity of disease can be evaluated by combination of T2 weighted MR images and MRCP alternative to contrast-enhanced CT. (author)

  1. Polio and the Vaccine (Shot) to Prevent It

    Science.gov (United States)

    ... and Teen Vaccine Resources Related Links Vaccines & Immunizations Polio and the Vaccine (Shot) to Prevent It Language: ... recommend all children get the vaccine. What is polio? Polio (or poliomyelitis) is a disease caused by ...

  2. Shot Noise in Negative-Differential-Conductance Devices

    National Research Council Canada - National Science Library

    Song, W

    2003-01-01

    The authors have compared the shot-noise properties at T = 4.2 K of a double-barrier resonant-tunneling diode and a superlattice tunnel diode, both of which exhibit negative differential-conductance (NDC...

  3. Flu shots and the characteristics of unvaccinated elderly Medicare beneficiaries.

    Science.gov (United States)

    Lochner, Kimberly A; Wynne, Marc

    2011-12-21

    Data from the Medicare Current Beneficiary Survey, 2009. • Overall, 73% of Medicare beneficiaries aged 65 years and older reported receiving a flu shot for the 2008 flu season, but vaccination rates varied by socio-demographic characteristics. Flu vaccination was lowest for beneficiaries aged 65-74 years old, who were non-Hispanic Blacks and Hispanics, were not married, had less than a high school education, or who were eligible for Medicaid (i.e., dual eligibles). • Healthcare utilization and personal health behavior were also related to vaccination rates, with current smokers and those with no hospitalizations or physician visits being less likely to be vaccinated. • Among those beneficiaries who reported receiving a flu shot, 59% received it in a physician's office or clinic, with the next most common setting being in the community (21%); e.g., grocery store, shopping mall, library, or church. • Among those beneficiaries who did not receive a flu shot, the most common reasons were beliefs that the shot could cause side effects or disease (20%), that they didn't think the shot could prevent the flu (17%), or that the shot wasn't needed (16%). Less than 1% reported that they didn't get the flu shot because of cost. Elderly persons (aged 65 years and older) are at increased risk of complications from influenza, with the majority of influenza-related hospitalizations and deaths occurring among the elderly (Fiore et al., 2010). Most physicians recommend their elderly patients get a flu shot each year, and many hospitals inquire about elderly patient's immunization status upon admission, providing a vaccination if requested. The importance of getting a flu shot is underscored by the Department of Health and Human Services' Healthy People initiative, which has set a vaccination goal of 90% for the Nation's elderly by the year 2020 (Department of Health and Human Services [DHHS], 2011). Although all costs related to flu shots are covered by Medicare, requiring

  4. SunShot Vision Study: February 2012 (Book)

    Energy Technology Data Exchange (ETDEWEB)

    2012-02-01

    The objective of the SunShot Vision Study is to provide an in-depth assessment of the potential for solar technologies to meet a significant share of electricity demand in the United States during the next several decades. Specifically, it explores a future in which the price of solar technologies declines by about 75% between 2010 and 2020 - in line with the U.S. Department of Energy (DOE) SunShot Initiative's targets.

  5. Single-shot spiral imaging at 7 T.

    Science.gov (United States)

    Engel, Maria; Kasper, Lars; Barmet, Christoph; Schmid, Thomas; Vionnet, Laetitia; Wilm, Bertram; Pruessmann, Klaas P

    2018-03-25

    The purpose of this work is to explore the feasibility and performance of single-shot spiral MRI at 7 T, using an expanded signal model for reconstruction. Gradient-echo brain imaging is performed on a 7 T system using high-resolution single-shot spiral readouts and half-shot spirals that perform dual-image acquisition after a single excitation. Image reconstruction is based on an expanded signal model including the encoding effects of coil sensitivity, static off-resonance, and magnetic field dynamics. The latter are recorded concurrently with image acquisition, using NMR field probes. The resulting image resolution is assessed by point spread function analysis. Single-shot spiral imaging is achieved at a nominal resolution of 0.8 mm, using spiral-out readouts of 53-ms duration. High depiction fidelity is achieved without conspicuous blurring or distortion. Effective resolutions are assessed as 0.8, 0.94, and 0.98 mm in CSF, gray matter and white matter, respectively. High image quality is also achieved with half-shot acquisition yielding image pairs at 1.5-mm resolution. Use of an expanded signal model enables single-shot spiral imaging at 7 T with unprecedented image quality. Single-shot and half-shot spiral readouts deploy the sensitivity benefit of high field for rapid high-resolution imaging, particularly for functional MRI and arterial spin labeling. © 2018 International Society for Magnetic Resonance in Medicine.

  6. Single-shot measurement of nonlinear absorption and nonlinear refraction.

    Science.gov (United States)

    Jayabalan, J; Singh, Asha; Oak, Shrikant M

    2006-06-01

    A single-shot method for measurement of nonlinear optical absorption and refraction is described and analyzed. A spatial intensity variation of an elliptical Gaussian beam in conjugation with an array detector is the key element of this method. The advantages of this single-shot technique were demonstrated by measuring the two-photon absorption and free-carrier absorption in GaAs as well as the nonlinear refractive index of CS2 using a modified optical Kerr setup.

  7. The single-shot opto-digitizer

    International Nuclear Information System (INIS)

    Nail, M.; Gibert, Ph.

    2000-01-01

    Laser-plasma experiments need to measure signals provided either by X-ray, photonic or neutronic detector. The measurement should have 50 GHz bandwidth and up to several hundred of Giga-Hertz for sub picosecond plasmas. For this purpose, a 35 GHz single shot opto-digitizer (10 ps risetime) has been studied and built. The device is made up of a 50 ohms microstrip propagation line, periodically lined by 100 sampled gates. The propagation line is long enough to measure a 400 ps duration. The sampling rate is 250 Gsa/s (every 4 ps). The sampled gates are made with fast recombining photo-material and turn on by a subpicosecond laser pulse which is synchronized exactly with the analysed phenomena. Every gate is recording to a storing capacitor. After the recording, every capacitor charge is needed to built the signal that was displayed on the propagation line. The dynamic range of measurement is 47 for the entire device. The device can measure positive or negative signals from 1.5 to 70 Volts. To increase the bandwidth, two another kinds of opto-digitizer were studied: one is a buried stripline with 56 GHz band width, the other a 70 GHz coplanar transmission line. For the purpose of subpicosecond plasmas, a 30 coplanar waveguide opto-digitizer was studied. Characteristics are as followed: window of measurement 40 ps, sampling rate 1 ps, bandwidth 230 GHz. Finally, a bundle of optical fibers was used to propagate the laser beam on semiconductor gates. If the gates are lighted at the same time, i.e. if the optical fibers have the same length, we get a simultaneous addressing. By using different lengths of optical fibers, we can do a sequential addressing. So, the sampling rate becomes a combination of the distance between two adjacent sampled channels, and the difference in length of optical fibers. (author)

  8. Biomechanical Analysis of the Jump Shot in Basketball

    Directory of Open Access Journals (Sweden)

    Struzik Artur

    2014-10-01

    Full Text Available Basketball players usually score points during the game using the jump shot. For this reason, the jump shot is considered to be the most important element of technique in basketball and requires a high level of performance. The aim of this study was to compare the biomechanical characteristics of the lower limbs during a jump shot without the ball and a countermovement jump without an arm swing. The differences between variables provide information about the potential that an athlete can utilise during a game when performing a jump shot. The study was conducted among 20 second-league basketball players by means of a Kistler force plate and the BTS SMART system for motion analysis. The variables measured included the take-off time, mean power, peak power, relative mean power, jump height, maximum landing force and calculated impact ratio. Surprisingly, more advantageous variables were found for the jump shot. This finding suggests a very high performance level in the jump shot in the studied group and a maximum utilisation of their motor abilities. Both types of jumps were characterised by high mean and peak power values and average heights. The high forces at landing, which result in considerable impact ratios, may have prompted the studied group to land softly. Use of the countermovement jump without an arm swing is recommended to assess and predict the progression of player’s jumping ability

  9. Shot reproducibility of the self-magnetic-pinch diode at 4.5 MV

    OpenAIRE

    Nichelle Bennett; M. Dale Crain; Darryl W. Droemer; Raymond E. Gignac; Greg Lare; Isidro Molina; Robert Obregon; Chase C. Smith; Frank L. Wilkins; Dale R. Welch; Steve Cordova; Manuel L. Gallegos; Mark D. Johnston; Mark L. Kiefer; Joshua J. Leckbee

    2014-01-01

    In experiments conducted at Sandia National Laboratories’ RITS-6 accelerator, the self-magnetic-pinch diode exhibits significant shot-to-shot variability. Specifically, for identical hardware operated at the same voltage, some shots exhibit a catastrophic drop in diode impedance. A study is underway to identify sources of shot-to-shot variations which correlate with diode impedance collapse. The scope of this report is limited to data collected at 4.5-MV peak voltage and sources of variabilit...

  10. Effect of shot peening on metastable austenitic stainless steels

    Energy Technology Data Exchange (ETDEWEB)

    Fargas, G., E-mail: gemma.fargas@upc.edu [CIEFMA - Departament de Ciència dels Materials i Enginyeria Metallúrgica, Universitat Politècnica de Catalunya, 08028 Barcelona (Spain); CRnE, Centre de Recerca en Nanoenginyeria, Universitat Politècnica de Catalunya, 08028 Barcelona (Spain); Roa, J.J.; Mateo, A. [CIEFMA - Departament de Ciència dels Materials i Enginyeria Metallúrgica, Universitat Politècnica de Catalunya, 08028 Barcelona (Spain); CRnE, Centre de Recerca en Nanoenginyeria, Universitat Politècnica de Catalunya, 08028 Barcelona (Spain)

    2015-08-12

    In this work, shot peening was performed in a metastable austenitic stainless steel EN 1.4318 (AISI 301LN) in order to evaluate its effect on austenite to martensite phase transformation and also the influence on the fatigue limit. Two different steel conditions were considered: annealed, i.e., with a fully austenitic microstructure, and cold rolled, consisting of a mixture of austenite and martensite. X-ray diffraction, electron back-scattered diffraction and focus ion beam, as well as nanoindentation techniques, were used to elucidate deformation mechanisms activated during shot peening and correlate with fatigue response. Results pointed out that extensive plastic deformation and phase transformation developed in annealed specimens as a consequence of shot peening. However, the increase of roughness and the generation of microcracks led to a limited fatigue limit improvement. In contrast, shot peened cold rolled specimens exhibited enhanced fatigue limit. In the latter case, the main factor that determined the influence on the fatigue response was the distance from the injector, followed successively by the exit speed of the shots and the coverage factor.

  11. Intra-shot MSE Calibration Technique For LHCD Experiments

    International Nuclear Information System (INIS)

    Ko, Jinseok; Scott, Steve; Shiraiwa, Syun'ichi; Greenwald, Martin; Parker, Ronald; Wallace, Gregory

    2009-01-01

    The spurious drift in pitch angle of order several degrees measured by the Motional Stark Effect (MSE) diagnostic in the Alcator C-Mod tokamak1 over the course of an experimental run day has precluded direct utilization of independent absolute calibrations. Recently, the underlying cause of the drift has been identified as thermal stress-induced birefringence in a set of in-vessel lenses. The shot-to-shot drift can be avoided by using MSE to measure only the change in pitch angle between a reference phase and a phase of physical interest within a single plasma discharge. This intra-shot calibration technique has been applied to the Lower Hybrid Current Drive (LHCD) experiments and the measured current profiles qualitatively demonstrate several predictions of LHCD theory such as an inverse dependence of current drive efficiency on the parallel refractive index and the presence of off-axis current drive.

  12. Shot H3837: Darht's First Dual-Axis Explosive Experiment

    Science.gov (United States)

    Mendez, Jacob; McNeil, Wendy Vogan; Harsh, James; Hull, Lawrence

    2011-06-01

    Test H3837 was the first explosive shot performed in front of both flash x-ray axes at the Los Alamos Dual Axis Radiographic HydroTest (DARHT) facility. Executed in November 2009, the shot was an explosively-driven metal flyer plate in a series of experiments designed to explore equation-of-state properties of shocked materials. Imaging the initial shock wave traveling through the flyer plate, DARHT Axis II captured the range of motion from the shock front emergence in the flyer to breakout at the free surface; the Axis I pulse provided a perpendicular perspective of the shot at a time coinciding with the third pulse of Axis II. Since the days of the Manhattan Project, penetrating radiography with multiple frames from different viewing angles has remained a high-profile goal at the Laboratory. H3837 is merely the beginning of a bright future for two-axis penetrating radiography.

  13. The Effect of Multiple Shot Peening on the Corrosion Behavior of Duplex Stainless Steel

    Science.gov (United States)

    Feng, Qiang; She, Jia; Wu, Xueyan; Wang, Chengxi; Jiang, Chuanhai

    2018-03-01

    Various types of shot peening treatments were applied to duplex stainless steel. The effects of shot peening intensity and working procedures on the microstructure were investigated. The domain size and microstrain evolution in the surface layer were characterized utilizing the Rietveld method. As the shot peening intensity increased, the surface roughness increased in the surface layer; however, it decreased after multiple (dual and triple) shot peening. The mole fraction of strain-induced martensite as a function of the intensity of shot peening was evaluated by XRD measurements. Both potentiodynamic polarization curves and salt spray tests of shot-peened samples in NaCl solution were investigated. The results indicate that traditional shot peening has negative effects on corrosion resistance with increasing shot peening intensity; however, the corrosion rate can be reduced by means of multiple shot peening.

  14. Analysis of shot-to-shot variability in post-disruption runaway electron currents for diverted DIII-D discharges

    International Nuclear Information System (INIS)

    Izzo, V A; Humphreys, D A; Kornbluth, M

    2012-01-01

    In DIII-D experiments, rapid termination by Ar-pellet injection sometimes produces a post-termination runaway electron (RE) current plateau, but this effect is highly non-reproducible on a shot-to-shot basis, particularly for diverted target plasmas. A set of DIII-D discharges is analyzed with two MHD codes to understand the relationship between the current profile of the target plasma and the amplitude of the RE current plateau. Using the linear stability code GATO, a correlation between the radial profile of the unstable n = 1 mode just after Ar-pellet injection and the observed appearance of an RE plateau is identified. Nonlinear NIMROD simulations with RE test-particle calculations directly predict RE confinement times during the disruption. With one exception, NIMROD predicts better RE confinement for shots in which higher RE currents were observed in DIII-D. But, the variation in confinement is primarily connected to the saturated n = 1 mode amplitude and not its radial profile. Still, both sets of analyses support the hypothesis that RE deconfinement by MHD fluctuations is a major factor in the shot-to-shot variability of RE plateaus, though additional factors such as seed current amplitude cannot be ruled out. (paper)

  15. Study on Plastic Deformation Characteristics of Shot Peening of Ni-Based Superalloy GH4079

    Science.gov (United States)

    Zhong, L. Q.; Liang, Y. L.; Hu, H.

    2017-09-01

    In this paper, the X-ray stress diffractometer, surface roughness tester, field emission scanning electron microscope(SEM), dynamic ultra-small microhardness tester were used to measure the surface residual stress and roughness, topography and surface hardness changes of GH4079 superalloy, which was processed by metallographic grinding, turning, metallographic grinding +shot peening and turning + shot peening. Analysized the effects of shot peening parameters on shot peening plastic deformation features; and the effects of the surface state before shot peening on shot peening plastic deformation characteristics. Results show that: the surface residual compressive stress, surface roughness and surface hardness of GH4079 superalloy were increased by shot peening, in addition, the increment of the surface residual compressive stress, surface roughness and surface hardness induced by shot peening increased with increasing shot peening intensity, shot peening time, shot peening pressure and shot hardness, but harden layer depth was not affected considerably. The more plastic deformation degree of before shot peening surface state, the less increment of the surface residual compressive stress, surface roughness and surface hardness induced by shot peening.

  16. Preparation of Ultracold Atom Clouds at the Shot Noise Level

    DEFF Research Database (Denmark)

    Gajdacz, M.; Hilliard, A. J.; Kristensen, Mick

    2016-01-01

    We prepare number stabilized ultracold atom clouds through the real-time analysis of nondestructive images and the application of feedback. In our experiments, the atom number N∼10^6 is determined by high precision Faraday imaging with uncertainty ΔN below the shot noise level, i.e., ΔN... on this measurement, feedback is applied to reduce the atom number to a user-defined target, whereupon a second imaging series probes the number stabilized cloud. By this method, we show that the atom number in ultracold clouds can be prepared below the shot noise level....

  17. Micro-MID Manufacturing By Two-Shot Injection Moulding

    DEFF Research Database (Denmark)

    Islam, Mohammad Aminul; Hansen, Hans Nørgaard; Tang, Peter Torben

    2008-01-01

    a specific MID process chain is used for micro products, many technical challenges are encountered which would not be problems for macro scale products. This paper investigates on a specific MID process chain (two shot moulding) and discusses the technical difficulties associated with the production process...

  18. Flu Shots, Mammogram, and the Perception of Probabilities

    NARCIS (Netherlands)

    Carman, K.G.; Kooreman, P.

    2010-01-01

    We study individuals’ decisions to decline or accept preventive health care interventions such as flu shots and mammograms. In particular, we analyze the role of perceptions of the effectiveness of the intervention, by eliciting individuals' subjective probabilities of sickness and survival, with

  19. Opening Shots and Loose Slots: adapting Las Vegas

    NARCIS (Netherlands)

    Goggin, J.

    2015-01-01

    Anyone who has ever seen a film set in Las Vegas will be familiar with opening shots of sensational neon signage clustered against the night sky. This montage sequence, now an established convention, leads the viewer on a thrilling joy-ride, generally beginning on Fremont Street in the old city

  20. SnapShot: O-Glycosylation Pathways across Kingdoms

    DEFF Research Database (Denmark)

    Joshi, Hiren J.; Narimatsu, Yoshiki; Schjoldager, Katrine T.

    2018-01-01

    O-glycosylation is one of the most abundant and diverse types of post-translational modifications of proteins. O-glycans modulate the structure, stability, and function of proteins and serve generalized as well as highly specific roles in most biological processes. This ShapShot presents types of......-glycans found in different organisms and their principle biosynthetic pathways...

  1. Assessment for One-Shot Library Instruction: A Conceptual Approach

    Science.gov (United States)

    Wang, Rui

    2016-01-01

    The purpose of this study is to explore a conceptual approach to assessment for one-shot library instruction. This study develops a new assessment instrument based on Carol Kuhlthau's information search process (ISP) model. The new instrument focuses on measuring and identifying changes in student readiness to do research along three…

  2. SunShot Catalyst Prize Competition Fact Sheet

    Energy Technology Data Exchange (ETDEWEB)

    Solar Energy Technologies Office

    2015-04-01

    This fact sheet is an overview of the Catalyst Energy Innovation Prize, an open innovation program launched in 2014 by the U.S. Department of Energy SunShot Initiative. This program aims to catalyze the rapid creation and development of products and solutions that address near-term challenges in the U.S. solar energy marketplace.

  3. One-shot valve may be remotely actuated

    Science.gov (United States)

    Kami, S.

    1965-01-01

    One-shot valve, with spring-loaded plunger and sealing diaphragm, incorporates an emergency release actuated by a remote sensor. The plunger is released by the electrical melting of a fuse link and pierces the valve seal. The valve lowers fluid pressure in a container without losing the contained fluid.

  4. Improvement of Surface Layer Characteristics by Shot Lining

    Science.gov (United States)

    Harada, Yasunori

    In the present study, lining of the metal with foils using shot peening was investigated to improve the surface layer characteristics. In the shot peening experiment, the foils set on the metal are pelted with hard particles traveling at a high velocity. The foils are bonded to the metal surface due to plastic deformation induced by the collision of the particles. The foils and the metal are heated to heighten the bondability because of the reduction of flow stress. Lining the metal with the hard powder sandwiched between two aluminum foil sheets was also attempted. In this experiment, a centrifugal shot peening machine wite an electrical heater was employed. The metals are commercially aluminium alloys and magnesium alloys, and the foils are commercially aluminum, titanium and nickel. The effects of shot speed and the heating temperature on the bondability were examined. Wear resistance was also evaluated by grinding. The foils were successfully bonded to the metal surface. It was found that the present method is effective in improving of surface layer characteristics.

  5. ON THE USE OF SHOT NOISE FOR PHOTON COUNTING

    Energy Technology Data Exchange (ETDEWEB)

    Zmuidzinas, Jonas, E-mail: jonas@caltech.edu [Division of Physics, Mathematics, and Astronomy, California Institute Institute of Technology, Pasadena, CA 91125 (United States)

    2015-11-01

    Lieu et al. have recently claimed that it is possible to substantially improve the sensitivity of radio-astronomical observations. In essence, their proposal is to make use of the intensity of the photon shot noise as a measure of the photon arrival rate. Lieu et al. provide a detailed quantum-mechanical calculation of a proposed measurement scheme that uses two detectors and conclude that this scheme avoids the sensitivity degradation that is associated with photon bunching. If correct, this result could have a profound impact on radio astronomy. Here I present a detailed analysis of the sensitivity attainable using shot-noise measurement schemes that use either one or two detectors, and demonstrate that neither scheme can avoid the photon bunching penalty. I perform both semiclassical and fully quantum calculations of the sensitivity, obtaining consistent results, and provide a formal proof of the equivalence of these two approaches. These direct calculations are furthermore shown to be consistent with an indirect argument based on a correlation method that establishes an independent limit to the sensitivity of shot-noise measurement schemes. Furthermore, these calculations are directly applicable to the regime of interest identified by Lieu et al. Collectively, these results conclusively demonstrate that the photon-bunching sensitivity penalty applies to shot-noise measurement schemes just as it does to ordinary photon counting, in contradiction to the fundamental claim made by Lieu et al. The source of this contradiction is traced to a logical fallacy in their argument.

  6. Gaze Embeddings for Zero-Shot Image Classification

    NARCIS (Netherlands)

    Karessli, N.; Akata, Z.; Schiele, B.; Bulling, A.

    2017-01-01

    Zero-shot image classification using auxiliary information, such as attributes describing discriminative object properties, requires time-consuming annotation by domain experts. We instead propose a method that relies on human gaze as auxiliary information, exploiting that even non-expert users have

  7. Movement symmetry and asymmetry of goal shots in female football ...

    African Journals Online (AJOL)

    This study examined the phenomenon of symmetrical skills in goal shot technique in female football players, of nine video recorded matches. The recording was taken during the 2nd Under 19 female football World Cup in 2004 and the 6th European female Championships of female seniors in 2005. The study comprised ...

  8. Optical properties (bidirectional reflectance distribution function) of shot fabric.

    Science.gov (United States)

    Lu, R; Koenderink, J J; Kappers, A M

    2000-11-01

    To study the optical properties of materials, one needs a complete set of the angular distribution functions of surface scattering from the materials. Here we present a convenient method for collecting a large set of bidirectional reflectance distribution function (BRDF) samples in the hemispherical scattering space. Material samples are wrapped around a right-circular cylinder and irradiated by a parallel light source, and the scattered radiance is collected by a digital camera. We tilted the cylinder around its center to collect the BRDF samples outside the plane of incidence. This method can be used with materials that have isotropic and anisotropic scattering properties. We demonstrate this method in a detailed investigation of shot fabrics. The warps and the fillings of shot fabrics are dyed different colors so that the fabric appears to change color at different viewing angles. These color-changing characteristics are found to be related to the physical and geometrical structure of shot fabric. Our study reveals that the color-changing property of shot fabrics is due mainly to an occlusion effect.

  9. RF Shot Noise Measurements in Au Atomic-scale Junctions

    Science.gov (United States)

    Chen, Ruoyu

    Conduction electrons are responsible for many physical or chemical phenomena in condensed matter systems, and their behavior can be directly studied by electronic transport measurements. In conventional transport measurements, conductance or resistance is usually the focus. Such a measurement can be as simple as a quick two terminal DC check by a multi-meter, or a more sophisticated lock-in measurement of multiple higher harmonic signals synchronized to different frequencies. Conductance carries direct information about the quasi-particle density of states and the local electronic distributions, which are usually Fermi-Dirac distribution. Conductance is modified or dominated by scattering from defacts or interfaces, and could also reflect the spin-spin exchange interactions or inelastic couplings with phonons and photons. Naturally one can ask the question: is there anything else we can measure electronically, which carries extra information that a conductance measurement does not provide? One answer to this question is the electronic noise. While the conductance reflects the average charge conduction ability of a system, noise describes how the physical quantities fluctuate around their average values. Some of the fluctuations carry information about their physical origins. This thesis will focus on one particular type of the electronic noise shot noise, but other types of noise will also be introduced and discussed. We choose to measure the radio frequency component of shot noise, combining with a modulated lock-in detection technique, which provides a method to largely get rid of other unwanted low-frequency noise signals. Au atomic-scale junctions are the systems we studied here. Au is relatively well understood and will not generate too many complications, so it's ideal as the first platform for us to understand both shot noise itself and our RF technique. On the other hand, the atomic scale raises fundamental questions about electronic transport and local

  10. Lower Extremity Muscle Activity During a Women's Overhand Lacrosse Shot

    Directory of Open Access Journals (Sweden)

    Millard Brianna M.

    2014-07-01

    Full Text Available The purpose of this study was to describe lower extremity muscle activity during the lacrosse shot. Participants (n=5 females, age 22±2 years, body height 162.6±15.2 cm, body mass 63.7±23.6 kg were free from injury and had at least one year of lacrosse experience. The lead leg was instrumented with electromyography (EMG leads to measure muscle activity of the rectus femoris (RF, biceps femoris (BF, tibialis anterior (TA, and medial gastrocnemius (GA. Participants completed five trials of a warm-up speed shot (Slow and a game speed shot (Fast. Video analysis was used to identify the discrete events defining specific movement phases. Full-wave rectified data were averaged per muscle per phase (Crank Back Minor, Crank Back Major, Stick Acceleration, Stick Deceleration. Average EMG per muscle was analyzed using a 4 (Phase x 2 (Speed ANOVA. BF was greater during Fast vs. Slow for all phases (p0.05. RF and GA were each influenced by the interaction of Phase and Speed (p<0.05 with GA being greater during Fast vs. Slow shots during all phases and RF greater during Crank Back Minor and Major as well as Stick Deceleration (p<0.05 but only tended to be greater during Stick Acceleration (p=0.076 for Fast vs. Slow. The greater muscle activity (BF, RF, GA during Fast vs. Slow shots may have been related to a faster approach speed and/or need to create a stiff lower extremity to allow for faster upper extremity movements.

  11. The effect of shot peening on notched low cycle fatigue

    International Nuclear Information System (INIS)

    Soady, K.A.; Mellor, B.G.; Shackleton, J.; Morris, A.; Reed, P.A.S.

    2011-01-01

    Highlights: → Shot peening improves notched component three point bend low cycle fatigue life. → Notch shape does not affect the efficacy of the peening process. → Strain hardening and residual stress effects need separate consideration. → Loading direction residual stresses do not relax under bend load. - Abstract: The improvement in low cycle fatigue life created by shot peening ferritic heat resistant steel was investigated in components of varying geometries based on those found in conventional power station steam turbine blades. It was found that the shape of the component did not affect the efficacy of the shot peening process, which was found to be beneficial even under the high stress amplitude three point bend loads applied. Furthermore, by varying the shot peening process parameters and considering fatigue life it has been shown that the three surface effects of shot peening; roughening, strain hardening and the generation of a compressive residual stress field must be included in remnant life models as physically separate entities. The compressive residual stress field during plane bending low cycle fatigue has been experimentally determined using X-ray diffraction at varying life fractions and found to be retained in a direction parallel to that of loading and to only relax to 80% of its original magnitude in a direction orthogonal to loading. This result, which contributes to the retention of fatigue life improvement in low cycle fatigue conditions, has been discussed in light of the specific stress distribution applied to the components. The ultimate aim of the research is to apply these results in a life assessment methodology which can be used to justify a reduction in the length of scheduled plant overhauls. This will result in significant cost savings for the generating utility.

  12. Some properties of focus points in one-shot decision theory

    OpenAIRE

    Guo, Peijun

    2011-01-01

    One-shot (one-time) decision problems concern the situations where a decision is experienced only once. Such one-shot decision problems are commonly encountered in business, economics and social systems. One-shot decision theory has been initially proposed by Guo [4]. The one-shot decision procedure comprises two steps. In the first step, a decision maker identifies which state of nature should be taken into account for each alternative amongst all available states of nature. These identified...

  13. A focal-spot diagnostic for on-shot characterization of high-energy petawatt lasers.

    Science.gov (United States)

    Bromage, J; Bahk, S-W; Irwin, D; Kwiatkowski, J; Pruyne, A; Millecchia, M; Moore, M; Zuegel, J D

    2008-10-13

    An on-shot focal-spot diagnostic for characterizing high-energy, petawatt-class laser systems is presented. Accurate measurements at full energy are demonstrated using high-resolution wavefront sensing in combination with techniques to calibrate on-shot measurements with low-power sample beams. Results are shown for full-energy activation shots of the OMEGA EP Laser System.

  14. An investigation of the properties of conventional and severe shot peened low alloy steel

    Science.gov (United States)

    Quang Trung, Pham; Butler, David Lee; Win Khun, Nay

    2017-07-01

    The effects of the conventional shot peening and severe shot peening process on the mechanical and tribological properties of shot peened AISI 4340 high strength steel were systematically investigated. Compared with the conventional shot peened sample, the ultrafine grain surface layer with a depth of about 20 µm generated by the severe shot peening process can enhance the hardness and wear resistance of the treated material. However, deeper dimples generated by the high media velocity in the severe shot peening process resulted in a higher surface roughness, which is considered as a side effect of this method reducing the fatigue life of the material. Applying a smaller shot size with an appropriate intensity can be used to peen the severe shot peened samples to not only reduce the surface roughness and friction coefficient but also improve the wear resistance for these samples. This work was presented in the shot peening section during ‘The 30th International Conference on Surface Modification Technologies, 2016, Milan, Italy’ (SMT30, ID 61, entitled ‘Comparison of the effects of conventional shot peening and severe shot peening processes on the mechanical and tribological properties of shot peened AISI 4340’) and the authors were encouraged to submit a manuscript to the Materials Research Express journal after adding some nessesary information.

  15. Networks of ·/G/∞ queues with shot-noise-driven arrival intensities

    NARCIS (Netherlands)

    Koops, D.T.; Boxma, O.J.; Mandjes, M.R.H.

    2017-01-01

    We study infinite-server queues in which the arrival process is a Cox process (or doubly stochastic Poisson process), of which the arrival rate is given by a shot-noise process. A shot-noise rate emerges naturally in cases where the arrival rate tends to exhibit sudden increases (or shots) at random

  16. Single-shot positron annihilation lifetime spectroscopy with LYSO scintillators

    Science.gov (United States)

    Alonso, A. M.; Cooper, B. S.; Deller, A.; Cassidy, D. B.

    2016-08-01

    We have evaluated the application of a lutetium yttrium oxyorthosilicate (LYSO) based detector to single-shot positron annihilation lifetime spectroscopy. We compare this detector directly with a similarly configured PbWO4 scintillator, which is the usual choice for such measurements. We find that the signal to noise ratio obtained using LYSO is around three times higher than that obtained using PbWO4 for measurements of Ps excited to longer-lived (Rydberg) levels, or when they are ionized soon after production. This is due to the much higher light output for LYSO (75% and 1% of NaI for LYSO and PbWO4 respectively). We conclude that LYSO is an ideal scintillator for single-shot measurements of positronium production and excitation performed using a low-intensity pulsed positron beam.

  17. Single-shot positron annihilation lifetime spectroscopy with LYSO scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, A.M., E-mail: a.alonso@ucl.ac.uk; Cooper, B.S.; Deller, A.; Cassidy, D.B.

    2016-08-21

    We have evaluated the application of a lutetium yttrium oxyorthosilicate (LYSO) based detector to single-shot positron annihilation lifetime spectroscopy. We compare this detector directly with a similarly configured PbWO{sub 4} scintillator, which is the usual choice for such measurements. We find that the signal to noise ratio obtained using LYSO is around three times higher than that obtained using PbWO{sub 4} for measurements of Ps excited to longer-lived (Rydberg) levels, or when they are ionized soon after production. This is due to the much higher light output for LYSO (75% and 1% of NaI for LYSO and PbWO{sub 4} respectively). We conclude that LYSO is an ideal scintillator for single-shot measurements of positronium production and excitation performed using a low-intensity pulsed positron beam.

  18. On the Path to SunShot - Executive Summary

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2016-05-01

    The halfway mark of the SunShot Initiative’s 2020 target date is a good time to take stock: How much progress has been made? What have we learned? What barriers and opportunities must still be addressed to ensure that solar technologies achieve cost parity in 2020 and realize their full potential in the decades beyond? To answer these questions, the Solar Energy Technology Office launched the On the Path to SunShot series in early 2015 in collaboration with the National Renewable Energy Laboratory (NREL) and with contributions from Lawrence Berkeley National Laboratory (LBNL), Sandia National Laboratories (SNL), and Argonne National Laboratory (ANL). The reports focus on the areas of technology development, systems integration, and market enablers.

  19. Short wavelength limits of current shot noise suppression

    International Nuclear Information System (INIS)

    Nause, Ariel; Dyunin, Egor; Gover, Avraham

    2014-01-01

    Shot noise in electron beam was assumed to be one of the features beyond control of accelerator physics. Current results attained in experiments at Accelerator Test Facility in Brookhaven and Linac Coherent Light Source in Stanford suggest that the control of the shot noise in electron beam (and therefore of spontaneous radiation and Self Amplified Spontaneous Emission of Free Electron Lasers) is feasible at least in the visible range of the spectrum. Here, we present a general linear formulation for collective micro-dynamics of e-beam noise and its control. Specifically, we compare two schemes for current noise suppression: a quarter plasma wavelength drift section and a combined drift/dispersive (transverse magnetic field) section. We examine and compare their limits of applicability at short wavelengths via considerations of electron phase-spread and the related Landau damping effect

  20. Short wavelength limits of current shot noise suppression

    Energy Technology Data Exchange (ETDEWEB)

    Nause, Ariel, E-mail: arielnau@post.tau.ac.il [Faculty of Exact Sciences, Department of Physics, Tel Aviv University, Tel Aviv (Israel); Dyunin, Egor; Gover, Avraham [Faculty of Engineering, Department of Physical Electronics, Tel Aviv University, Tel Aviv (Israel)

    2014-08-15

    Shot noise in electron beam was assumed to be one of the features beyond control of accelerator physics. Current results attained in experiments at Accelerator Test Facility in Brookhaven and Linac Coherent Light Source in Stanford suggest that the control of the shot noise in electron beam (and therefore of spontaneous radiation and Self Amplified Spontaneous Emission of Free Electron Lasers) is feasible at least in the visible range of the spectrum. Here, we present a general linear formulation for collective micro-dynamics of e-beam noise and its control. Specifically, we compare two schemes for current noise suppression: a quarter plasma wavelength drift section and a combined drift/dispersive (transverse magnetic field) section. We examine and compare their limits of applicability at short wavelengths via considerations of electron phase-spread and the related Landau damping effect.

  1. The Distribution of the Interval between Events of a Cox Process with Shot Noise Intensity

    Directory of Open Access Journals (Sweden)

    Angelos Dassios

    2008-01-01

    Full Text Available Applying piecewise deterministic Markov processes theory, the probability generating function of a Cox process, incorporating with shot noise process as the claim intensity, is obtained. We also derive the Laplace transform of the distribution of the shot noise process at claim jump times, using stationary assumption of the shot noise process at any times. Based on this Laplace transform and from the probability generating function of a Cox process with shot noise intensity, we obtain the distribution of the interval of a Cox process with shot noise intensity for insurance claims and its moments, that is, mean and variance.

  2. Music video shot segmentation using independent component analysis and keyframe extraction based on image complexity

    Science.gov (United States)

    Li, Wei; Chen, Ting; Zhang, Wenjun; Shi, Yunyu; Li, Jun

    2012-04-01

    In recent years, Music video data is increasing at an astonishing speed. Shot segmentation and keyframe extraction constitute a fundamental unit in organizing, indexing, retrieving video content. In this paper a unified framework is proposed to detect the shot boundaries and extract the keyframe of a shot. Music video is first segmented to shots by illumination-invariant chromaticity histogram in independent component (IC) analysis feature space .Then we presents a new metric, image complexity, to extract keyframe in a shot which is computed by ICs. Experimental results show the framework is effective and has a good performance.

  3. Multivariate Product-Shot-noise Cox Point Process Models

    DEFF Research Database (Denmark)

    Jalilian, Abdollah; Guan, Yongtao; Mateu, Jorge

    We introduce a new multivariate product-shot-noise Cox process which is useful for model- ing multi-species spatial point patterns with clustering intra-specific interactions and neutral, negative or positive inter-specific interactions. The auto and cross pair correlation functions of the process...... can be obtained in closed analytical forms and approximate simulation of the process is straightforward. We use the proposed process to model interactions within and among five tree species in the Barro Colorado Island plot....

  4. SnapShot: Hormones of the gastrointestinal tract.

    Science.gov (United States)

    Coate, Katie C; Kliewer, Steven A; Mangelsdorf, David J

    2014-12-04

    Specialized endocrine cells secrete a variety of peptide hormones all along the gastrointestinal (GI) tract, making it one of the largest endocrine organs in the body. Nutrients and developmental and neural cues trigger the secretion of gastrointestinal (GI) hormones from specialized endocrine cells along the GI tract. These hormones act in target tissues to facilitate digestion and regulate energy homeostasis. This SnapShot summarizes the production and functions of GI hormones. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Distributions of Conductance and Shot Noise and Associated Phase Transitions

    International Nuclear Information System (INIS)

    Vivo, Pierpaolo; Majumdar, Satya N.; Bohigas, Oriol

    2008-01-01

    For a chaotic cavity with two identical leads each supporting N channels, we compute analytically, for large N, the full distribution of the conductance and the shot noise power and show that in both cases there is a central Gaussian region flanked on both sides by non-Gaussian tails. The distribution is weakly singular at the junction of Gaussian and non-Gaussian regimes, a direct consequence of two phase transitions in an associated Coulomb gas problem

  6. Project Rulison: post-shot plans and evaluations

    Energy Technology Data Exchange (ETDEWEB)

    1969-12-01

    Project Rulison post-shot plans and evaluations are discussed and include physical characteristics of the Rulison cavity; pressure and temperature expected in the cavity; amount, nature, and distribution of radioactivity in the cavity; reentry plan; radioactive species which may be encountered during reentry; public safety considerations arising from release of radioactivity; procedures to assure public safety; and the radiological safety plan. Maximum hypothetical accidents and ecological considerations are discussed in the appendices.

  7. SnapShot: Fanconi anemia and associated proteins.

    Science.gov (United States)

    Wang, Anderson T; Smogorzewska, Agata

    2015-01-15

    Fanconi anemia is a genetic disorder resulting from biallelic mutations in one of the 17 FANC genes. It is characterized by congenital abnormalities, bone marrow failure, and cancer predisposition. The underlying cause is genomic instability resulting from the deficiency in replication-dependent DNA interstrand crosslink repair pathway commonly referred to as the Fanconi anemia-BRCA pathway. This SnapShot presents the key factors involved. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Zero-Shot Learning by Generating Pseudo Feature Representations

    OpenAIRE

    Lu, Jiang; Li, Jin; Yan, Ziang; Zhang, Changshui

    2017-01-01

    Zero-shot learning (ZSL) is a challenging task aiming at recognizing novel classes without any training instances. In this paper we present a simple but high-performance ZSL approach by generating pseudo feature representations (GPFR). Given the dataset of seen classes and side information of unseen classes (e.g. attributes), we synthesize feature-level pseudo representations for novel concepts, which allows us access to the formulation of unseen class predictor. Firstly we design a Joint Att...

  9. Transfer of mechanical energy during the shot put

    Directory of Open Access Journals (Sweden)

    Błażkiewicz Michalina

    2016-09-01

    Full Text Available The aim of this study was to analyse transfer of mechanical energy between body segments during the glide shot put. A group of eight elite throwers from the Polish National Team was analysed in the study. Motion analysis of each throw was recorded using an optoelectronic Vicon system composed of nine infrared camcorders and Kistler force plates. The power and energy were computed for the phase of final acceleration of the glide shot put. The data were normalized with respect to time using the algorithm of the fifth order spline and their values were interpolated with respect to the percentage of total time, assuming that the time of the final weight acceleration movement was different for each putter. Statistically significant transfer was found in the study group between the following segments: Right Knee – Right Hip (p = 0.0035, Left Hip - Torso (p = 0.0201, Torso – Right Shoulder (p = 0.0122 and Right Elbow – Right Wrist (p = 0.0001. Furthermore, the results of cluster analysis showed that the kinetic chain used during the final shot acceleration movement had two different models. Differences between the groups were revealed mainly in the energy generated by the hips and trunk.

  10. First-time viewers' comprehension of films: bridging shot transitions.

    Science.gov (United States)

    Ildirar, Sermin; Schwan, Stephan

    2015-02-01

    Which perceptual and cognitive prerequisites must be met in order to be able to comprehend a film is still unresolved and a controversial issue. In order to gain some insights into this issue, our field experiment investigates how first-time adult viewers extract and integrate meaningful information across film cuts. Three major types of commonalities between adjacent shots were differentiated, which may help first-time viewers with bridging the shots: pictorial, causal, and conceptual. Twenty first-time, 20 low-experienced and 20 high-experienced viewers from Turkey were shown a set of short film clips containing these three kinds of commonalities. Film clips conformed also to the principles of continuity editing. Analyses of viewers' spontaneous interpretations show that first-time viewers indeed are able to notice basic pictorial (object identity), causal (chains of activity), as well as conceptual (links between gaze direction and object attention) commonalities between shots due to their close relationship with everyday perception and cognition. However, first-time viewers' comprehension of the commonalities is to a large degree fragile, indicating the lack of a basic notion of what constitutes a film. © 2014 The British Psychological Society.

  11. IMPACT OF SHOTS ON FINAL SCORE OF A FOOTBALL MATCH

    Directory of Open Access Journals (Sweden)

    Miroslav Radoman

    2008-08-01

    Full Text Available The research has been done on a sample of 64 played games on the World championship FIFA, World Cup Germany 2006 and 128 results of the games divided in three integrals according to the score (win, defeat and unresolved score . The analysis is done according to the total number of shots during the game. Considering the results that are got and their interpretations, we could conclude that the results of data analysis in which is used the multi-method of MANOVA analysis and discriminative analysis, has shown that there are significant difference in frequency of the games result (win, defeat or unresolved score in shots element during the game. Even thou the noticed difference in frequency are not equally expressed, the results that are got have insinuated that there are significant differences in followed elements of the football game. Implemented analysis (royev test i T-test have confirmed that in every analyzed elements of the shot there are statistically significant differences in the result of the game (win, defeat, unresolved score and that the differences in shot’s elements are consequence different selection of the tactics and techniques also the ability of their realization in the stage of at tack and defense.

  12. Muscular power, neuromuscular activation, and performance in shot put athletes at preseason and at competition period.

    Science.gov (United States)

    Kyriazis, Thomas A; Terzis, Gerasimos; Boudolos, Konstantinos; Georgiadis, Georgios

    2009-09-01

    The aim of this study was to investigate changes in shot put performance, muscular power, and neuromuscular activation of the lower extremities, between the preseason and the competition period, in skilled shot put athletes using the rotational technique. Shot put performance was assessed at the start of the pre-season period as well as after 12 weeks, at the competition period, in nine shot putters. Electromyographic (EMG) activity of the right vastus lateralis muscle was recorded during all shot put trials. Maximum squat strength (1RM) and mechanical parameters during the countermovement jump (CMJ) on a force platform were also determined at pre-season and at competition period. Shot put performance increased 4.7% (p phase was increased significantly (p training period. Shot put performance was significantly related with muscular power and takeoff velocity during the CMJ, at competition period (r = 0.66, p competition period.

  13. A Shot Parameter Specification Subsystem for automated control of PBFA [Particle Beam Fusion Accelerator] II accelerator shots

    International Nuclear Information System (INIS)

    Spiller, J.L.

    1987-01-01

    The Shot Parameter Specification Subsystem (SPSS) is an integral part of the automatic control system developed for the Particle Beam Fusion Accelerator II (PBFA II) by the Control Monitor (C/M) Software Development Team. This system has been designed to fully utilize the accelerator by tailoring shot parameters to the needs of the experimenters. The SPSS is the key to this flexibility. Automatic systems will be required on many pulsed power machines for the fastest turnaround, the highest reliability, and most cost effective operation. These systems will require the flexibility and the ease of use that is part of the SPSS. The PBFA II control system has proved to be an effective modular system, flexible enough to meet the demands of both the fast track construction of PBFA II and the control needs of Hermes III at the Simulation Technology Laboratory. This system is expected to meet the demands of most future machine changes

  14. Effects of Rayleigh damping, friction and rate-dependency on 3D residual stress simulation of angled shot peening

    International Nuclear Information System (INIS)

    Kim, Taehyung; Lee, Hyungyil; Hyun, Hong Chul; Jung, Sunghwan

    2013-01-01

    Highlights: ► We propose a 3D FE model to study peening residual stress involving angled shots. ► The FE model set with plastic shot are found to best match the X-ray diffraction data. ► The model provides 3D multi-shot impact FE solution with various incidence angles. - Abstract: In this study, we propose a 3D finite element (FE) model to study shot peening involving angled shots. Using the FE model for angled shot peening, we examine relationships with the residual stress introduced by shot peening of the factors such as the Rayleigh damping in the material, dynamic friction, and the rate dependency of the material and systematically integrate them with the FE model. The FE model is set with rigid shot, elastic shot, and plastic shot respectively. Plastic deformation of the shot is also explored with the FE model. The FE model is applied to study angled multi-shots. The FE results are verified with experimental data using X-ray diffraction (XRD). The FE model set with plastic shot are found to best match the XRD results validating accuracy of the 3D FE model properly integrated with the factors and plastically deformable shot ball. The proposed model will serve to simulate actual shot peening cases, which generally involve multi-shots with various incidence angles

  15. A prospective pilot study: Can the biliary tree be visualized in children younger than 3 months on Magnetic Resonance Cholangiopancreatography?

    Energy Technology Data Exchange (ETDEWEB)

    Siles, Pascale [La Timone Children' s Hospital, Department of Radiology, Marseille (France); Aschero, Audrey; Gorincour, Guillaume; Bourliere-Najean, Brigitte; Petit, Philippe [La Timone Children' s Hospital, Department of Pediatric Radiology, Marseille (France); Roquelaure, Bertrand [La Timone Children' s Hospital, Department of Pediatrics, Marseille (France); Delarue, Arnauld [La Timone Children' s Hospital, Department of Pediatric Surgery, Marseille (France)

    2014-09-15

    Magnetic resonance cholangiopancreatography (MRCP) could aid in the diagnosis of biliary atresia, a hepatic pathology with thin, irregular or interrupted biliary ducts. There is little published evidence of MRCP appearances in normal neonates and young infants. To assess the use of MR cholangiopancreatography in visualizing the biliary tree in neonates and infants younger than 3 months with no hepatobiliary disorder, and to assess this visibility in relationship to the child's age, weight, and sedation and fasting states. Between December 2008 and October 2010 our department performed MRI of the brain, orbits and face on 16 full-term neonates and infants. Each child was younger than 3 months (90 days) and without any hepatobiliary disorders. The children were scanned with a respiratory-gated 0.54 x 0.51 x 0.4-mm{sup 3} 3-D MRCP sequence. We used a reading grid to assess subjectively the visibility of the extrahepatic bile ducts along with extrahepatic bile duct confluence. The visibility of the extrahepatic bile duct confluence was assessed against age, weight, and sedation and fasting states. The extrahepatic bile duct confluence was seen in 10 children out of 16 (62.5%). In the neonate sub-group (corrected age younger than 30 days), the MRCP was technically workable and the extrahepatic bile duct confluence was seen in four cases out of eight (50%). This visualization was up to 75% in the subgroup older than 30 days. However, statistically there was no significant difference in visibility of the extrahepatic bile duct confluence in relationship to age, weight or MRCP performance conditions (feeding, fasting or sedation). The complete normal biliary system (extrahepatic bile duct confluence included) is not consistently visualized in infants younger than 3 months old on non-enhanced MRCP. Thus the use of MRCP to exclude a diagnosis of biliary atresia is compromised at optimal time of surgery. (orig.)

  16. A prospective pilot study: Can the biliary tree be visualized in children younger than 3 months on Magnetic Resonance Cholangiopancreatography?

    International Nuclear Information System (INIS)

    Siles, Pascale; Aschero, Audrey; Gorincour, Guillaume; Bourliere-Najean, Brigitte; Petit, Philippe; Roquelaure, Bertrand; Delarue, Arnauld

    2014-01-01

    Magnetic resonance cholangiopancreatography (MRCP) could aid in the diagnosis of biliary atresia, a hepatic pathology with thin, irregular or interrupted biliary ducts. There is little published evidence of MRCP appearances in normal neonates and young infants. To assess the use of MR cholangiopancreatography in visualizing the biliary tree in neonates and infants younger than 3 months with no hepatobiliary disorder, and to assess this visibility in relationship to the child's age, weight, and sedation and fasting states. Between December 2008 and October 2010 our department performed MRI of the brain, orbits and face on 16 full-term neonates and infants. Each child was younger than 3 months (90 days) and without any hepatobiliary disorders. The children were scanned with a respiratory-gated 0.54 x 0.51 x 0.4-mm 3 3-D MRCP sequence. We used a reading grid to assess subjectively the visibility of the extrahepatic bile ducts along with extrahepatic bile duct confluence. The visibility of the extrahepatic bile duct confluence was assessed against age, weight, and sedation and fasting states. The extrahepatic bile duct confluence was seen in 10 children out of 16 (62.5%). In the neonate sub-group (corrected age younger than 30 days), the MRCP was technically workable and the extrahepatic bile duct confluence was seen in four cases out of eight (50%). This visualization was up to 75% in the subgroup older than 30 days. However, statistically there was no significant difference in visibility of the extrahepatic bile duct confluence in relationship to age, weight or MRCP performance conditions (feeding, fasting or sedation). The complete normal biliary system (extrahepatic bile duct confluence included) is not consistently visualized in infants younger than 3 months old on non-enhanced MRCP. Thus the use of MRCP to exclude a diagnosis of biliary atresia is compromised at optimal time of surgery. (orig.)

  17. Effects of single antegrade hot shot in comparison with no hot shot administration during coronary artery bypass grafting

    Directory of Open Access Journals (Sweden)

    Pouya Mirmohammadsadeghi

    2015-05-01

    Full Text Available BACKGROUND: Superior results will be achieved from cardiac surgery by minimizing the effect of ischemia/reperfusion injury during cross-clamping of the aorta. Different cardioplegia solutions have been introduced, but the optimum one is still ambiguous. The aim of this study is to determine the effect of single antegrade hot shot terminal warm blood cardioplegia (TWBC on patients who had undergone coronary artery bypass grafting (CABG. METHODS: In total, 2488 patients who had CABG surgery in Sina Hospital, Isfahan, Iran, from 2003 to 2011 were enrolled in this case-control study. They were divided into two groups, those who received cold cardioplegia only and those who received a hot shot following cold cardioplegia. Demographics, and clinical data, such as; premature atrial contraction (PAC arrhythmia, diabetes treatment, and left ventricular ejection fraction (EF, were collected and logistic regression analysis was used to analyze the data. RESULTS: There were significant differences found between subjects receiving antegrade hot shot based on direct current (DC shocks, with regard to; female, EF levels, diabetes treatment (P < 0.050. Those who did not receive the hot shot and were not diabetic received more DC shock (P = 0.019. The prevalence of subjects who did no need DC shock was significantly higher among male subjects who had good EF and acceptable diabetic treatment. Multiple logistic regression showed that PAC arrhythmia did not have a significant effect on receiving DC shock during CAGB [0.84 (0.25, 2.85, (P = 0.780]. Having poor EF increased the risk of receiving DC shock among subjects by 2.81 [(1.69, 4.69, (P ≤ 0.001] (P < 0.001. Among the diabetic subjects, receiving insulin decreased the risk of receiving DC shock by 0.54 (0.29, 0.98 (P = 0.042. CONCLUSION: It was concluded that single antegrade hot shot following cold cardioplegia was not particularly effective in the CABG group. TWBC will decrease the need for DC shock.   

  18. Imaging diagnosis of intraductal papillary mucinous tumor of the pancreas

    International Nuclear Information System (INIS)

    Zhang Huimao; Lai Ying; Yang Shuqin; Yang Haishan; Murakami, K.

    2005-01-01

    Objective: To explore the diagnostic value of intraductal papillary mucinous tumor (IPMT) of the pancreas, and to assess its clinical and characteristic radiological features. Methods: Thirty-six cases with IPMT who underwent CT and MRI with plain and contrast enhancement before operation were reviewed. The clinical presentation and characteristic imaging findings of main duct type (8 cases) and branch duct type (28 cases) were retrospectively reviewed. Results: Typical imaging findings of main duct type were segmental or diffuse dilation of MPD (diameter was over 9 mm) with enhanced mural nodules after contrast medium administration. MR cholangiopancreatography (MRCP) showed dilation of MPD with flat/nodule filling defects in 4 cases and MPD dilatation in the head side in 2 cases. Branch duct type was more frequently located in the head or uncinate. Typical imaging findings of branch duct type were unilocular or multilocular cystic tumors with septa, mural nodules, and MPD dilatation. MRCP showed septa in 24 cases, filling defects in 15 cases, and MPD dilatation in 8 cases. Communication between the cystic lesion and the MPD was demonstrated in 19 cases by MRCP. Conclusion: It is extremely important to accurately make the diagnosis of IPMT for planning the surgical strategy. MRCP is a noninvasive and useful method in detecting and making definite diagnosis of IPMT. (authors)

  19. Shot noise of spin current and spin transfer torque

    Science.gov (United States)

    Yu, Yunjin; Zhan, Hongxin; Wan, Langhui; Wang, Bin; Wei, Yadong; Sun, Qingfeng; Wang, Jian

    2013-04-01

    We report the theoretical investigation of the shot noise of the spin current (Sσ) and the spin transfer torque (Sτ) for non-collinear spin polarized transport in a spin-valve device which consists of a normal scattering region connected by two ferromagnetic electrodes (MNM system). Our theory was developed using the non-equilibrium Green’s function method, and general nonlinear Sσ - V and Sτ - V relations were derived as a function of the angle θ between the magnetizations of two leads. We have applied our theory to a quantum dot system with a resonant level coupled with two ferromagnetic electrodes. It was found that, for the MNM system, the auto-correlation of the spin current is enough to characterize the fluctuation of the spin current. For a system with three ferromagnetic layers, however, both auto-correlation and cross-correlation of the spin current are needed to characterize the noise of the spin current. For a quantum dot with a resonant level, the derivative of spin torque with respect to bias voltage is proportional to sinθ when the system is far away from resonance. When the system is near resonance, the spin transfer torque becomes a non-sinusoidal function of θ. The derivative of the noise of the spin transfer torque with respect to the bias voltage Nτ behaves differently when the system is near or far away from resonance. Specifically, the differential shot noise of the spin transfer torque Nτ is a concave function of θ near resonance while it becomes a convex function of θ far away from resonance. For certain bias voltages, the period Nτ(θ) becomes π instead of 2π. For small θ, it was found that the differential shot noise of the spin transfer torque is very sensitive to the bias voltage and the other system parameters.

  20. Shot noise of spin current and spin transfer torque

    International Nuclear Information System (INIS)

    Yu Yunjin; Zhan Hongxin; Wan Langhui; Wang Bin; Wei Yadong; Sun Qingfeng; Wang Jian

    2013-01-01

    We report the theoretical investigation of the shot noise of the spin current (S σ ) and the spin transfer torque (S τ ) for non-collinear spin polarized transport in a spin-valve device which consists of a normal scattering region connected by two ferromagnetic electrodes (MNM system). Our theory was developed using the non-equilibrium Green’s function method, and general nonlinear S σ − V and S τ − V relations were derived as a function of the angle θ between the magnetizations of two leads. We have applied our theory to a quantum dot system with a resonant level coupled with two ferromagnetic electrodes. It was found that, for the MNM system, the auto-correlation of the spin current is enough to characterize the fluctuation of the spin current. For a system with three ferromagnetic layers, however, both auto-correlation and cross-correlation of the spin current are needed to characterize the noise of the spin current. For a quantum dot with a resonant level, the derivative of spin torque with respect to bias voltage is proportional to sinθ when the system is far away from resonance. When the system is near resonance, the spin transfer torque becomes a non-sinusoidal function of θ. The derivative of the noise of the spin transfer torque with respect to the bias voltage N τ behaves differently when the system is near or far away from resonance. Specifically, the differential shot noise of the spin transfer torque N τ is a concave function of θ near resonance while it becomes a convex function of θ far away from resonance. For certain bias voltages, the period N τ (θ) becomes π instead of 2π. For small θ, it was found that the differential shot noise of the spin transfer torque is very sensitive to the bias voltage and the other system parameters. (paper)

  1. Methodology for calculating guideline concentrations for safety shot sites

    International Nuclear Information System (INIS)

    1997-06-01

    Residual plutonium (Pu), with trace quantities of depleted uranium (DU) or weapons grade uranium (WU), exists in surficial soils at the Nevada Test Site (NTS), Nellis Air Force Range (NAFR), and the Tonopah Test Range (TTR) as the result of the above-ground testing of nuclear weapons and special experiments involving the detonation of plutonium-bearing devices. The special experiments (referred to as safety shots) involving plutonium-bearing devices were conducted to study the behavior of Pu as it was being explosively compressed; ensure that the accidental detonation of the chemical explosive in a production weapon would not result in criticality; evaluate the ability of personnel to manage large-scale Pu dispersal accidents; and develop criteria for transportation and storage of nuclear weapons. These sites do not pose a health threat to either workers or the general public because they are under active institutional control. The DOE is committed to remediating the safety shot sites so that radiation exposure to the public, both now and in the future, will be maintained within the established limits and be as low as reasonably achievable. Remediation requires calculation of a guideline concentration for the Pu, U, and their decay products that are present in the surface soil. This document presents the methodology for calculating guideline concentrations of weapons grade plutonium, weapons grade uranium, and depleted uranium in surface soils at the safety shot sites. Emphasis is placed on obtaining site-specific data for use in calculating dose to potential residents from the residual soil contamination

  2. Ranking TEM cameras by their response to electron shot noise

    International Nuclear Information System (INIS)

    Grob, Patricia; Bean, Derek; Typke, Dieter; Li, Xueming; Nogales, Eva; Glaeser, Robert M.

    2013-01-01

    We demonstrate two ways in which the Fourier transforms of images that consist solely of randomly distributed electrons (shot noise) can be used to compare the relative performance of different electronic cameras. The principle is to determine how closely the Fourier transform of a given image does, or does not, approach that of an image produced by an ideal camera, i.e. one for which single-electron events are modeled as Kronecker delta functions located at the same pixels where the electrons were incident on the camera. Experimentally, the average width of the single-electron response is characterized by fitting a single Lorentzian function to the azimuthally averaged amplitude of the Fourier transform. The reciprocal of the spatial frequency at which the Lorentzian function falls to a value of 0.5 provides an estimate of the number of pixels at which the corresponding line-spread function falls to a value of 1/e. In addition, the excess noise due to stochastic variations in the magnitude of the response of the camera (for single-electron events) is characterized by the amount to which the appropriately normalized power spectrum does, or does not, exceed the total number of electrons in the image. These simple measurements provide an easy way to evaluate the relative performance of different cameras. To illustrate this point we present data for three different types of scintillator–coupled camera plus a silicon-pixel (direct detection) camera. - Highlights: ► Fourier amplitude spectra of noise are well fitted by a single Lorentzian. ► This measures how closely, or not, the response approaches the single-pixel ideal. ► Noise in the Fourier amplitudes is (1−π/4) times the shot noise power spectrum. ► Finite variance in the single-electron responses adds to the output noise. ► This excess noise may be equal to or greater than shot noise itself

  3. Methodology for calculating guideline concentrations for safety shot sites

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    Residual plutonium (Pu), with trace quantities of depleted uranium (DU) or weapons grade uranium (WU), exists in surficial soils at the Nevada Test Site (NTS), Nellis Air Force Range (NAFR), and the Tonopah Test Range (TTR) as the result of the above-ground testing of nuclear weapons and special experiments involving the detonation of plutonium-bearing devices. The special experiments (referred to as safety shots) involving plutonium-bearing devices were conducted to study the behavior of Pu as it was being explosively compressed; ensure that the accidental detonation of the chemical explosive in a production weapon would not result in criticality; evaluate the ability of personnel to manage large-scale Pu dispersal accidents; and develop criteria for transportation and storage of nuclear weapons. These sites do not pose a health threat to either workers or the general public because they are under active institutional control. The DOE is committed to remediating the safety shot sites so that radiation exposure to the public, both now and in the future, will be maintained within the established limits and be as low as reasonably achievable. Remediation requires calculation of a guideline concentration for the Pu, U, and their decay products that are present in the surface soil. This document presents the methodology for calculating guideline concentrations of weapons grade plutonium, weapons grade uranium, and depleted uranium in surface soils at the safety shot sites. Emphasis is placed on obtaining site-specific data for use in calculating dose to potential residents from the residual soil contamination.

  4. Single-shot positron annihilation lifetime spectroscopy with LYSO scintillators

    OpenAIRE

    Alonso, A. M.; Cooper, B. S.; Deller, A.; Cassidy, D. B.

    2016-01-01

    We have evaluated the application of a lutetium yttrium oxyorthosilicate (LYSO) based detector to single-shot positron annihilation lifetime spectroscopy. We compare this detector directly with a similarly configured PbWO4 scintillator, which is the usual choice for such measurements. We find that the signal to noise ratio obtained using LYSO is around three times higher than that obtained using PbWO4 for measurements of Ps excited to longer-lived (Rydberg) levels, or when they are ionized so...

  5. Multi-shot analysis of the gamma reaction history diagnostic

    International Nuclear Information System (INIS)

    Sayre, D. B.; Bernstein, L. A.; Church, J. A.; Stoeffl, W.; Herrmann, H. W.

    2012-01-01

    The gamma reaction history diagnostic at the National Ignition Facility has the capability to determine a number of important performance metrics for cryogenic deuterium-tritium implosions: the fusion burn width, bang time and yield, as well as the areal density of the compressed ablator. Extracting those values from the measured γ rays of an implosion, requires accounting for a γ-ray background in addition to the impulse response function of the instrument. To address these complications, we have constructed a model of the γ-ray signal, and are developing a simultaneous multi-shot fitting routine to constrain its parameter space.

  6. The example of the UK SHOT haemovigilance system

    Directory of Open Access Journals (Sweden)

    Perla Eleftheriou

    2014-12-01

    Full Text Available SHOT (Serious Hazards of Transfusion scheme is the UK’s National confidential haemovigilance system, and was set up in 1996. It is an independent, confidential, professionally led haemovigilance scheme. Initially the reporting was voluntary but now required by several professional bodies. SHOT publishes annual reports with recommendations and circulates to all relevant organizations including the 4 UK Blood services, Departments of Health in England, Wales, Scotland and Northern Ireland, all relevant professional bodies and reporting hospitals. Over the 17 years of reporting, the evidence gathered has prompted changes in transfusion practice from the selection and management of donors to changes in hospital practice, better education and training. Acute transfusion reactions and transfusion-associated circulatory overload carry the highest risk for morbidity and death. Greatest risk to patients remain errors in the process at the point of blood sampling, in the laboratory and at bedside administration. SHOT’s objectives are to use findings to improve standards of hospital transfusion practice, to educate users on transfusion hazards and prevention, to aid production of clinical guidelines in blood transfusion and to inform national policy on transfusion safety. MHRA is the UK competent authority to which serious adverse reactions and events have to be reported annually. Overall the most common adverse incidents are caused by errors, resulting in the transfusion of an incorrect component or one that does not meet the specific requirements of the patient (e.g. not irradiated or not appropriately antigen matched. TACO (transfusion associated circulatory overload accounts for most deaths and major morbidity reported to SHOT but is overall underreported. Transfusions are not always given appropriately. This may be due to wrong haemoglobin results, failure to assess patients appropriately, or avoidable use of emergency O RhD negative units because

  7. One-shot service searches: Preprint repositories at a mouseclick

    International Nuclear Information System (INIS)

    Canessa, E.; Pastore, G.

    1996-09-01

    In this article we introduce the ICTP-International Centre for Theoretical Physics's prototype for a ''One-Shot World-Wide Preprints Search'' on the Web. This is a new centralized interface for a global search throughout the most popular scientific preprint repositories. Herein, we briefly discuss our experience with the implementation of this service and propose it as a possible alternative solution to the problem of getting access to the information without being either overloaded with lots of new documents or not being informed at all. (author). 13 refs, 3 figs

  8. Start-Up of FEL Oscillator from Shot Noise

    International Nuclear Information System (INIS)

    Kumar, V.; Krishnagopal, S.; Fawley, W.M.

    2007-01-01

    In free-electron laser (FEL) oscillators, as in self-amplified spontaneous emission (SASE) FELs, the buildup of cavity power starts from shot noise resulting from the discreteness of electronic charge. It is important to do the start-up analysis for the build-up of cavity power in order to fix the macropulse width from the electron accelerator such that the system reaches saturation. In this paper, we use the time-dependent simulation code GINGER [1]to perform this analysis. We present results of this analysis for the parameters of the Compact Ultrafast TErahertz FEL (CUTE-FEL) [2] being built at RRCAT

  9. The effect of controlled shot peening on fusion welded joints

    International Nuclear Information System (INIS)

    Lah, Nur Azida Che; Ali, Aidy; Ismail, Napsiah; Chai, Lim Poon; Mohamed, Abdul Aziz

    2010-01-01

    This work examines the effect of controlled shot peening (CSP) treatment on the fatigue strength of an ASTM A516 grade 70 carbon steel welded joint. Metallurgical modifications, hardness, elemental compositions, and internal discontinuities, such as porosity, inclusions, lack of penetration, and undercut found in treated and untreated fusion welded joints, were characterized. The fatigue results of as-welded and peened skimmed joints were compared. It was observed that the effect of the CSP and skimming processes improved the fatigue life of the fusion weld by 50% on MMA-welded, 63% on MIG-welded, and 60% on TIG-welded samples.

  10. Modeling Microbunching from Shot Noise Using Vlasov Solvers

    International Nuclear Information System (INIS)

    Venturini, Marco; Venturini, Marco; Zholents, Alexander

    2008-01-01

    Unlike macroparticle simulations, which are sensitive to unphysical statistical fluctuations when the number of macroparticles is smaller than the bunch population, direct methods for solving the Vlasov equation are free from sampling noise and are ideally suited for studying microbunching instabilities evolving from shot noise. We review a 2D (longitudinal dynamics) Vlasov solver we have recently developed to study the microbunching instability in the beam delivery systems for x-ray FELs and present an application to FERMI(at)Elettra. We discuss, in particular, the impact of the spreader design on microbunching

  11. One-shot service searches: Preprint repositories at a mouseclick

    Energy Technology Data Exchange (ETDEWEB)

    Canessa, E [International Centre for Theoretical Physics, Trieste (Italy); Pastore, G [Trieste Univ., Trieste (Italy). Dipt. di Fisica

    1996-09-01

    In this article we introduce the ICTP-International Centre for Theoretical Physics`s prototype for a ``One-Shot World-Wide Preprints Search`` on the Web. This is a new centralized interface for a global search throughout the most popular scientific preprint repositories. Herein, we briefly discuss our experience with the implementation of this service and propose it as a possible alternative solution to the problem of getting access to the information without being either overloaded with lots of new documents or not being informed at all. (author). 13 refs, 3 figs.

  12. Single-shot 35 fs temporal resolution electron shadowgraphy

    Energy Technology Data Exchange (ETDEWEB)

    Scoby, C. M.; Li, R. K.; Threlkeld, E.; To, H.; Musumeci, P. [Department of Physics and Astronomy, UCLA, Los Angeles, California 90095 (United States)

    2013-01-14

    We obtain single-shot time-resolved shadowgraph images of the electromagnetic fields resulting from the interaction of a high intensity ultrashort laser pulse with a metal surface. Using a high brightness relativistic electron beam and a high streaking speed radiofrequency deflector, we report <35 fs temporal resolution enabling a direct visualization of the retarded-time dominated field evolution which follows the laser-induced charge emission. A model including the finite signal propagation speed well reproduces the data and yields measurements of fundamental parameters in short pulse laser-matter interaction such as the amount of emitted charge and the emission time scale.

  13. Single-shot 35 fs temporal resolution electron shadowgraphy

    International Nuclear Information System (INIS)

    Scoby, C. M.; Li, R. K.; Threlkeld, E.; To, H.; Musumeci, P.

    2013-01-01

    We obtain single-shot time-resolved shadowgraph images of the electromagnetic fields resulting from the interaction of a high intensity ultrashort laser pulse with a metal surface. Using a high brightness relativistic electron beam and a high streaking speed radiofrequency deflector, we report <35 fs temporal resolution enabling a direct visualization of the retarded-time dominated field evolution which follows the laser-induced charge emission. A model including the finite signal propagation speed well reproduces the data and yields measurements of fundamental parameters in short pulse laser-matter interaction such as the amount of emitted charge and the emission time scale.

  14. The finite element analysis for prediction of residual stresses induced by shot peening

    International Nuclear Information System (INIS)

    Kim, Cheol; Yang, Won Ho; Sung, Ki Deug; Cho, Myoung Rae; Ko, Myung Hoon

    2000-01-01

    The shot peening is largely used for a surface treatment in which small spherical parts called shots are blasted on a surface of a metallic components with velocities up to 100m/s. This treatment leads to an improvement of fatigue behavior due to the developed compressive residual stresses, and so it has gained widespread acceptance in the automobile and aerospace industries. The residual stress profile on surface layer depends on the parameters of shot peening, which are, shot velocity, shot diameter, coverage, impact angle, material properties etc. and the method to confirm this profile is only measurement by X-ray diffractometer. Despite its importance to automobile and aerospace industries, little attention has been devoted to the accurate modeling of the process. In this paper, the simulation technique is applied to predict the magnitude and distribution of the residual stress and plastic deformation caused by shot peening with the help of the finite element analysis

  15. Numerical investigation of a shot peening process by a finite element approach

    DEFF Research Database (Denmark)

    Liu, Hongsheng; Zhang, Xiaodan; Hansen, Niels

    2014-01-01

    Shot peening is a surface impact treatment widely used to improve the performance of a metal or a component. The better performance of the shot peened part is controlled by compressive residual stresses resulting from the plastic deformation of the surface layers by impacts of shot. The compressive...... residual stress is generally measured by X-ray diffraction. However, considerable cost and time are needed for such measurements. For this reason, in this work a 3D finite element (FE) model is introduced for a shot peening process. Through the FE simulations, the effect of process parameters...... such as damping ratio of material, friction coefficient, shot velocity and shot angle on the magnitude and distribution of the compressive residual stress is examined....

  16. Clinical application of multi-shot diffusion EPI in neurological disease

    International Nuclear Information System (INIS)

    Ishihara, Tetsuya; Hirata, Koichi; Kubo, Jin; Yamazaki, Kaoru; Sato, Toshihiko

    1998-01-01

    Using the multi-shot EPI method we investigated the clinical application of diffusion weighted imaging (DWI) in the diagnosis of neurological disease. The multi-shot method provided better susceptibility artifact-free DWI than the single-shot method particularly in the region of the posterior cranial fossa. DWI using the multi-shot EPI method readily shows the pyramidal tract extending from the internal capsule to the brainstems which is inaccessible by the conventional single-shot EPI method, and providing three-dimensional and distinct images of pyramidal tract changes in amyotrophic lateral sclerosis or cerebral infarction with pyramidal tract disturbance. Our findings suggest that the use of DWI with the multi-shot EPI method would provide a technique for the easy diagnosis and evaluation of various neurological diseases. (author)

  17. Clinical application of multi-shot diffusion EPI in neurological disease

    Energy Technology Data Exchange (ETDEWEB)

    Ishihara, Tetsuya; Hirata, Koichi; Kubo, Jin; Yamazaki, Kaoru [Dokkyo Univ., Mibu, Tochigi (Japan). School of Medicine; Sato, Toshihiko

    1998-05-01

    Using the multi-shot EPI method we investigated the clinical application of diffusion weighted imaging (DWI) in the diagnosis of neurological disease. The multi-shot method provided better susceptibility artifact-free DWI than the single-shot method particularly in the region of the posterior cranial fossa. DWI using the multi-shot EPI method readily shows the pyramidal tract extending from the internal capsule to the brainstems which is inaccessible by the conventional single-shot EPI method, and providing three-dimensional and distinct images of pyramidal tract changes in amyotrophic lateral sclerosis or cerebral infarction with pyramidal tract disturbance. Our findings suggest that the use of DWI with the multi-shot EPI method would provide a technique for the easy diagnosis and evaluation of various neurological diseases. (author)

  18. IMPACT OF VIBRATORY AND ROTATIONAL SHOT PEENING ONTO SELECTED PROPERTIES OF TITANIUM ALLOY SURFACE LAYER

    Directory of Open Access Journals (Sweden)

    Kazimierz Zaleski

    2014-06-01

    Full Text Available This study presents the results of tests on impact of vibratory and rotational shot peening of the Ti6A12Mo2Cr titanium alloy onto the processed object surface roughness and surface layer microhardness. The external surfaces of ring-shaped samples were shot peened. The preceding process consisted of turning with a cubic boron nitride blade knife. Steel beads, having a diameter of 6 mm, were used as a processing medium. The variable parameters of shot peening were vibrator amplitude and shot peening time. The range of recommended technological parameters for vibratory and rotational shot peening was determined. As a result of shot peening, the surface roughness could be reduced by approximately 4 times and the surface layer could be hardened to the depth of approximately 0.4 mm.

  19. Temperature dependence of shot noise in double barrier magnetic tunnel junctions

    Science.gov (United States)

    Niu, Jiasen; Liu, Liang; Feng, J. F.; Han, X. F.; Coey, J. M. D.; Zhang, X.-G.; Wei, Jian

    2018-03-01

    Shot noise reveals spin dependent transport properties in a magnetic tunnel junction. We report measurement of shot noise in CoFeB/MgO/CoFeB/MgO/CoFeB double barrier magnetic tunnel junctions, which shows a strong temperature dependence. The Fano factor used to characterize shot noise increases with decreasing temperature. A sequential tunneling model can be used to account for these results, in which a larger Fano factor results from larger spin relaxation length at lower temperatures.

  20. Lead shot pellets dispersed by hunters: ingested by ducks

    Energy Technology Data Exchange (ETDEWEB)

    Danell, K [Univ. of Umea, Sweden; Andersson, A; Marcstrom, V

    1977-01-01

    Many of the lead pellets shot by waterfowl hunters over shores and waters fall on the feeding grounds of ducks and geese. These pellets, picked up and ingested by the birds, can remain in the gizzard where they are eroded by mechanical and chemical action. In some cases the bird absorbs enough lead to cause lead poisoning. This report describes the incidence of ingested lead shot pellets found in 928 ducks collected in Sweden during hunting season. Pellets were found in both dabbling and diving ducks and were present in birds from six of the eight localities sampled. Usually one or two pellets were found but some ducks contained up to 62 pellets. As the incidence of ingested pellets in the present study is approximately the same as that found in North America, where the annual duck loss due to lead poisoning is estimated to be 2 to 3 percent of the population, it may be assumed that lead poisoning is a mortality factor for Swedish ducks also.

  1. Single-Shot MR Spectroscopic Imaging with Partial Parallel Imaging

    Science.gov (United States)

    Posse, Stefan; Otazo, Ricardo; Tsai, Shang-Yueh; Yoshimoto, Akio Ernesto; Lin, Fa-Hsuan

    2010-01-01

    An MR spectroscopic imaging (MRSI) pulse sequence based on Proton-Echo-Planar-Spectroscopic-Imaging (PEPSI) is introduced that measures 2-dimensional metabolite maps in a single excitation. Echo-planar spatial-spectral encoding was combined with interleaved phase encoding and parallel imaging using SENSE to reconstruct absorption mode spectra. The symmetrical k-space trajectory compensates phase errors due to convolution of spatial and spectral encoding. Single-shot MRSI at short TE was evaluated in phantoms and in vivo on a 3 T whole body scanner equipped with 12-channel array coil. Four-step interleaved phase encoding and 4-fold SENSE acceleration were used to encode a 16×16 spatial matrix with 390 Hz spectral width. Comparison with conventional PEPSI and PEPSI with 4-fold SENSE acceleration demonstrated comparable sensitivity per unit time when taking into account g-factor related noise increases and differences in sampling efficiency. LCModel fitting enabled quantification of Inositol, Choline, Creatine and NAA in vivo with concentration values in the ranges measured with conventional PEPSI and SENSE-accelerated PEPSI. Cramer-Rao lower bounds were comparable to those obtained with conventional SENSE-accelerated PEPSI at the same voxel size and measurement time. This single-shot MRSI method is therefore suitable for applications that require high temporal resolution to monitor temporal dynamics or to reduce sensitivity to tissue movement. PMID:19097245

  2. Caffeine Content in Popular Energy Drinks and Energy Shots.

    Science.gov (United States)

    Attipoe, Selasi; Leggit, Jeffrey; Deuster, Patricia A

    2016-09-01

    The use of energy beverages is high among the general population and military personnel. Previous studies have reported discrepancies between the actual amount of caffeine in products and the amount of caffeine on stated labels. Thus, the purpose of this study was to examine the content of caffeine listed on the labels of various energy drinks and energy shots. Top-selling energy drinks (n = 9) and energy shots (n = 5) were purchased from retail stores. Three of each of the 14 products were purchased and analyzed for caffeine content by an independent laboratory. Of the 14 products tested, 5 did not provide caffeine amounts on their facts panel-of those, 3 listed caffeine as an ingredient and 2 listed caffeine as part of a proprietary blend. The remaining 9 (of 14) products stated the amounts of caffeine on their labels, all of which were within 15% of the amount indicated on the label. In this study, although the energy beverages that indicated the amount of caffeine it contained had values within ±15% of the amount listed on the label, a potentially acceptable range, this finding is not acceptable with regard to current labeling regulations, which require added ingredients to total 100%. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.

  3. Shot-Noise Limited Time-Encoded Raman Spectroscopy

    Directory of Open Access Journals (Sweden)

    Sebastian Karpf

    2017-01-01

    Full Text Available Raman scattering, an inelastic scattering mechanism, provides information about molecular excitation energies and can be used to identify chemical compounds. Albeit being a powerful analysis tool, especially for label-free biomedical imaging with molecular contrast, it suffers from inherently low signal levels. This practical limitation can be overcome by nonlinear enhancement techniques like stimulated Raman scattering (SRS. In SRS, an additional light source stimulates the Raman scattering process. This can lead to orders of magnitude increase in signal levels and hence faster acquisition in biomedical imaging. However, achieving a broad spectral coverage in SRS is technically challenging and the signal is no longer background-free, as either stimulated Raman gain (SRG or loss (SRL is measured, turning a sensitivity limit into a dynamic range limit. Thus, the signal has to be isolated from the laser background light, requiring elaborate methods for minimizing detection noise. Here, we analyze the detection sensitivity of a shot-noise limited broadband stimulated time-encoded Raman (TICO-Raman system in detail. In time-encoded Raman, a wavelength-swept Fourier domain mode locking (FDML laser covers a broad range of Raman transition energies while allowing a dual-balanced detection for lowering the detection noise to the fundamental shot-noise limit.

  4. Finding the gap: An empirical study of the most effective shots in elite goalball.

    Directory of Open Access Journals (Sweden)

    Daniel Link

    Full Text Available This research identifies which shots types in goalball are most likely to lead to a goal and herby provides background information for improving training and competition. Therefore, we observed 117 elite level matches including 20,541 shots played in the regular situation (3 vs. 3 using notational analysis. We characterized the shots by using their target sector (A-E, technique (traditional, rotation, trajectory (flat, bounce, angle (straight, diagonal and outcome (goal, violation, out, blocked. In our data, a χ2-test showed a significantly higher goal rate for men (3.9% compared to women (3.0%. For men, we found a significantly higher goal rate in the intersection sectors between players C (5.6%, D (4.9%, and in the outer sector A. In sector A, goal rate was higher only for straight shots (6.6%. Technique and trajectory did not affect goal rate for men, but flat shots showed a higher violation rate (3.2% compared to bounce shouts (2.0%. In women's goalball, goal rate was higher only on sector D (4.4%. Bounce-rotation shots were the most successful (5.5%. We conclude that men should focus on shots to sectors C and D (called pocket and straight shots to sector A, as long as there are no other tactical considerations. Women should shoot primarily towards the pocket. It might also be worth playing more bounce-rotation shots and practicing them in training.

  5. Finding the gap: An empirical study of the most effective shots in elite goalball.

    Science.gov (United States)

    Link, Daniel; Weber, Christoph

    2018-01-01

    This research identifies which shots types in goalball are most likely to lead to a goal and herby provides background information for improving training and competition. Therefore, we observed 117 elite level matches including 20,541 shots played in the regular situation (3 vs. 3) using notational analysis. We characterized the shots by using their target sector (A-E), technique (traditional, rotation), trajectory (flat, bounce), angle (straight, diagonal and outcome (goal, violation, out, blocked). In our data, a χ2-test showed a significantly higher goal rate for men (3.9%) compared to women (3.0%). For men, we found a significantly higher goal rate in the intersection sectors between players C (5.6%), D (4.9%), and in the outer sector A. In sector A, goal rate was higher only for straight shots (6.6%). Technique and trajectory did not affect goal rate for men, but flat shots showed a higher violation rate (3.2%) compared to bounce shouts (2.0%). In women's goalball, goal rate was higher only on sector D (4.4%). Bounce-rotation shots were the most successful (5.5%). We conclude that men should focus on shots to sectors C and D (called pocket) and straight shots to sector A, as long as there are no other tactical considerations. Women should shoot primarily towards the pocket. It might also be worth playing more bounce-rotation shots and practicing them in training.

  6. Study on the use of types of shots in Valencian Handball on professional players

    Directory of Open Access Journals (Sweden)

    José Antonio Martínez Carbonell

    2013-01-01

    Full Text Available Due to the shortage of studies of analysis in Valencian ball, we have centred this study on this sport. The aim of study has been to analyze and to quantify the types of shots , and to compare the same ones between the positions of game of 1st game line (resto and 2nd game line (medio. Analysis of 6 games of the 19th Professional League of Stand and rope 2009-2010 was carried out so i, and specifically of 12 players, using Sports Code analysis software. The results indicate significant differences (p<0.05 between the shots carried out by first game line player and second game line in the rebound and rebound-shot all of them of right and left hand,and stand shot right hand; being almost realitzados only by players from the first game line position. At the same time we find data which demonstrate us by another band used mainly by second game line players beatings, these have been volley shot, volley shot after bounce, volley shot under the line of the shoulders, palm shot and horizontal shot all of them of right hand. As conclusion of the study, we have obtained that depending on the position of game the players use a few types of I throb or others. Therefore, we affirm, that the analysis of the high performance in stand and rope from the advances of the technologies, a valuable information contributes us to establish specific bosses of training.

  7. Different types of asynchronous music and effects on performance of basketball foul shot.

    Science.gov (United States)

    Geisler, G; Leith, L M

    2001-12-01

    48 undergraduate women performed basketball foul shots with and without background music. Slow music, fast music, and music personally selected by subjects did not significantly affect shooting performance.

  8. The Numerical FEM Model of the Kinematics of the Vibratory Shot Peening Process

    Directory of Open Access Journals (Sweden)

    Stanisław Bławucki

    2017-12-01

    Full Text Available The paper presents the results of numerical calculations, with the finite element method in the ABAQUS program environment, of the vibratory shot peening process with loose peening elements. The behaviour of shot peening elements was analysed in the kinematic aspect. The impact of the initial deployment of vibratory shot peening elements on their behaviour during processing was investigated, including the displacement, velocity, acceleration and the number of collisions. The way of determining the effectiveness of the processing with the vibratory shot peening was illustrated.

  9. A study on corrosive behavior of spring steel by shot-peening process

    International Nuclear Information System (INIS)

    An, Jae Pil; Park, Keyung Dong

    2004-01-01

    In this study, the influence of shot peening on the corrosion was investigated on spring steel immersed in 3.5% NaCl. The immersion test was performed on the two kinds of specimens. Corrosion potential, polarization curve, residual stress and etc. were investigated from experimental results. From test results, the effect of shot peening on the corrosion was evaluated. In case of corrosion potential, shot peened specimen shows more activated negative direction as compared with parent metal. Surface of specimen, which is treated with the shot peened, is placed as more activated state against inner base metal. It can cause the anti-corrosion effect on the base metal

  10. Hepatic involvement of Langerhans cell histiocytosis in children - imaging findings of computed tomography, magnetic resonance imaging and magnetic resonance cholangiopancreatography

    International Nuclear Information System (INIS)

    Shi, Yingyan; Qiao, Zhongwei; Gong, Ying; Yang, Haowei; Li, Guoping; Pa, Mier; Xia, Chunmei

    2014-01-01

    Langerhans cell histiocytosis is a rare disease that occurs mainly in children, and hepatic involvement is generally a poor prognostic factor. To describe CT and MRI findings of hepatic involvement of Langerhans cell histiocytosis in children, especially the abnormal bile duct manifestation on magnetic resonance cholangiopancreatography (MRCP). Thirteen children (seven boys, six girls; mean age 28.9 months) were diagnosed with disseminated Langerhans cell histiocytosis. They underwent CT (n = 5) or MRI (n = 4), or CT and MRI examinations (n = 4) to evaluate the liver involvement. Periportal abnormalities presented as band-like or nodular lesions on CT and MRI in all 13 children. The hepatic parenchymal lesions were found in the peripheral regions of the liver in seven children, including multiple nodules on MRI (n = 6), and cystic-like lesions on CT and MRI (n = 3). In 11 of the 13 children the dilatations of the bile ducts were observed on CT and MRI. Eight of the 13 children underwent MR cholangiopancreatography, which demonstrated stenoses or segmental stenoses with slight dilatation of the central bile ducts, including the common hepatic duct and its first-order branches. The peripheral bile ducts in these children showed segmental dilatations and stenoses. Stenosis of the central bile ducts revealed by MR cholangiopancreatography was the most significant finding of liver involvement in Langerhans cell histiocytosis in children. (orig.)

  11. Hepatic involvement of Langerhans cell histiocytosis in children - imaging findings of computed tomography, magnetic resonance imaging and magnetic resonance cholangiopancreatography

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Yingyan; Qiao, Zhongwei; Gong, Ying; Yang, Haowei; Li, Guoping; Pa, Mier [Children' s Hospital of Fudan University, Department of Radiology, Shanghai (China); Xia, Chunmei [Shanghai Medical College of Fudan University, Physiology and Pathophysiology Department, Shanghai (China)

    2014-06-15

    Langerhans cell histiocytosis is a rare disease that occurs mainly in children, and hepatic involvement is generally a poor prognostic factor. To describe CT and MRI findings of hepatic involvement of Langerhans cell histiocytosis in children, especially the abnormal bile duct manifestation on magnetic resonance cholangiopancreatography (MRCP). Thirteen children (seven boys, six girls; mean age 28.9 months) were diagnosed with disseminated Langerhans cell histiocytosis. They underwent CT (n = 5) or MRI (n = 4), or CT and MRI examinations (n = 4) to evaluate the liver involvement. Periportal abnormalities presented as band-like or nodular lesions on CT and MRI in all 13 children. The hepatic parenchymal lesions were found in the peripheral regions of the liver in seven children, including multiple nodules on MRI (n = 6), and cystic-like lesions on CT and MRI (n = 3). In 11 of the 13 children the dilatations of the bile ducts were observed on CT and MRI. Eight of the 13 children underwent MR cholangiopancreatography, which demonstrated stenoses or segmental stenoses with slight dilatation of the central bile ducts, including the common hepatic duct and its first-order branches. The peripheral bile ducts in these children showed segmental dilatations and stenoses. Stenosis of the central bile ducts revealed by MR cholangiopancreatography was the most significant finding of liver involvement in Langerhans cell histiocytosis in children. (orig.)

  12. Spent shot availability and ingestion on areas managed for mourning doves

    Science.gov (United States)

    Schulz, J.H.; Millspaugh, J.J.; Washburn, B.E.; Wester, G.R.; Lanigan, J. T.; Franson, J.C.

    2002-01-01

    Mourning dove (Zenaida macroura) hunting is becoming increasingly popular, especially in managed shooting fields. Given the possible increase in the availability of lead (Pb) shot on these areas, our objective was to estimate availability and ingestion of spent shot at the Eagle Bluffs Conservation Area (EBCA, hunted with nontoxic shot) and the James A. Reed Memorial Wildlife Area (JARWA, hunted with Pb shot) in Missouri. During 1998, we collected soil samples one or 2 weeks prior to the hunting season (prehunt) and after 4 days of dove hunting (posthunt). We also collected information on number of doves harvested, number of shots fired, shotgun gauge, and shotshell size used. Dove carcasses were collected on both areas during 1998-99. At EBCA, 60 hunters deposited an estimated 64,775 pellets/ha of nontoxic shot on or around the managed field. At JARWA, approximately 1,086,275 pellets/ha of Pb shot were deposited by 728 hunters. Our posthunt estimates of spent-shot availability from soil sampling were 0 pellets/ha for EBCA and 6,342 pellets/ha for JARWA. Our findings suggest that existing soil sampling protocols may not provide accurate estimates of spent-shot availability in managed dove shooting fields. During 1998-99, 15 of 310 (4.8%) mourning doves collected from EBCA had ingested nontoxic shot. Of those doves, 6 (40.0%) contained a?Y7 shot pellets. In comparison, only 2 of 574 (0.3%) doves collected from JARWA had ingested Pb shot. Because a greater proportion of doves ingested multiple steel pellets compared to Pb pellets, we suggest that doves feeding in fields hunted with Pb shot may succumb to acute Pb toxicosis and thus become unavailable to harvest, resulting in an underestimate of ingestion rates. Although further research is needed to test this hypothesis, our findings may partially explain why previous studies have shown few doves with ingested Pb shot despite their feeding on areas with high Pb shot availability.

  13. Single-shot polarimetry imaging of multicore fiber.

    Science.gov (United States)

    Sivankutty, Siddharth; Andresen, Esben Ravn; Bouwmans, Géraud; Brown, Thomas G; Alonso, Miguel A; Rigneault, Hervé

    2016-05-01

    We report an experimental test of single-shot polarimetry applied to the problem of real-time monitoring of the output polarization states in each core within a multicore fiber bundle. The technique uses a stress-engineered optical element, together with an analyzer, and provides a point spread function whose shape unambiguously reveals the polarization state of a point source. We implement this technique to monitor, simultaneously and in real time, the output polarization states of up to 180 single-mode fiber cores in both conventional and polarization-maintaining fiber bundles. We demonstrate also that the technique can be used to fully characterize the polarization properties of each individual fiber core, including eigen-polarization states, phase delay, and diattenuation.

  14. Study of transient turbine shot without bypass in a BWR

    International Nuclear Information System (INIS)

    Vallejo Q, J. A.; Martin del Campo M, C.; Fuentes M, L.; Francois L, J. L.

    2015-09-01

    The study and analysis of operational transients are important for predicting the behavior of a system to short-terms events and the impact that would cause this transition. For the nuclear industry these studies are indispensable due to economic, environmental and social impacts that could result in an accident during the operation of a nuclear reactor. In this paper the preparation, simulation and analysis of results of a turbine shot transient, which is not taken into operation the bypass is presented. The study is realized for a BWR of 2027 MWt, to an intermediate cycle life and using the computer code Simulate-3K a depressurization stage of the vessel is created which shows the response of other security systems and gives a coherent prediction to the event presented type. (Author)

  15. Shot noise in systems with semi-Dirac points

    International Nuclear Information System (INIS)

    Zhai, Feng; Wang, Juan

    2014-01-01

    We calculate the ballistic conductance and shot noise of electrons through a two-dimensional stripe system (width W ≫ length L) with semi-Dirac band-touching points. We find that the ratio between zero-temperature noise power and mean current (the Fano factor) is highly anisotropic. When the transport is along the linear-dispersion direction and the Fermi energy is fixed at the semi-Dirac point, the Fano factor has a universal value F = 0.179 while a minimum conductivity exists and scales with L 1∕2 . Along the parabolic dispersion direction, the Fano factor at the semi-Dirac point has a contact-independent limit exceeding 0.9, which varies weakly with L due to the common-path interference of evanescent waves. Our findings suggest a way to discern the type of band-touching points

  16. Comparison of optimization algorithms for the slow shot phase in HPDC

    Science.gov (United States)

    Frings, Markus; Berkels, Benjamin; Behr, Marek; Elgeti, Stefanie

    2018-05-01

    High-pressure die casting (HPDC) is a popular manufacturing process for aluminum processing. The slow shot phase in HPDC is the first phase of this process. During this phase, the molten metal is pushed towards the cavity under moderate plunger movement. The so-called shot curve describes this plunger movement. A good design of the shot curve is important to produce high-quality cast parts. Three partially competing process goals characterize the slow shot phase: (1) reducing air entrapment, (2) avoiding temperature loss, and (3) minimizing oxide caused by the air-aluminum contact. Due to the rough process conditions with high pressure and temperature, it is hard to design the shot curve experimentally. There exist a few design rules that are based on theoretical considerations. Nevertheless, the quality of the shot curve design still depends on the experience of the machine operator. To improve the shot curve it seems to be natural to use numerical optimization. This work compares different optimization strategies for the slow shot phase optimization. The aim is to find the best optimization approach on a simple test problem.

  17. Who Takes Advantage of Free Flu Shots? Examining the Effects of an Expansion in Coverage

    NARCIS (Netherlands)

    Carman, K.G.; Mosca, I.

    2011-01-01

    Because of the high risk of costly complications (including death) and the externalities of contagious diseases, many countries provide free flu shots to certain populations free of charge. This paper examines the expansion of the free flu shot program in the Netherlands. This program expanded in

  18. Time-resolved single-shot terahertz time-domain spectroscopy for ultrafast irreversible processes

    Science.gov (United States)

    Zhai, Zhao-Hui; Zhong, Sen-Cheng; Li, Jun; Zhu, Li-Guo; Meng, Kun; Li, Jiang; Liu, Qiao; Peng, Qi-Xian; Li, Ze-Ren; Zhao, Jian-Heng

    2016-09-01

    Pulsed terahertz spectroscopy is suitable for spectroscopic diagnostics of ultrafast events. However, the study of irreversible or single shot ultrafast events requires ability to record transient properties at multiple time delays, i.e., time resolved at single shot level, which is not available currently. Here by angular multiplexing use of femtosecond laser pulses, we developed and demonstrated a time resolved, transient terahertz time domain spectroscopy technique, where burst mode THz pulses were generated and then detected in a single shot measurement manner. The burst mode THz pulses contain 2 sub-THz pulses, and the time gap between them is adjustable up to 1 ns with picosecond accuracy, thus it can be used to probe the single shot event at two different time delays. The system can detect the sub-THz pulses at 0.1 THz-2.5 THz range with signal to noise ratio (SNR) of ˜400 and spectrum resolution of 0.05 THz. System design was described here, and optimizations of single shot measurement of THz pulses were discussed in detail. Methods to improve SNR were also discussed in detail. A system application was demonstrated where pulsed THz signals at different time delays of the ultrafast process were successfully acquired within single shot measurement. This time resolved transient terahertz time domain spectroscopy technique provides a new diagnostic tool for irreversible or single shot ultrafast events where dynamic information can be extracted at terahertz range within one-shot experiment.

  19. Shot reproducibility of the self-magnetic-pinch diode at 4.5 MV

    Directory of Open Access Journals (Sweden)

    Nichelle Bennett

    2014-05-01

    Full Text Available In experiments conducted at Sandia National Laboratories’ RITS-6 accelerator, the self-magnetic-pinch diode exhibits significant shot-to-shot variability. Specifically, for identical hardware operated at the same voltage, some shots exhibit a catastrophic drop in diode impedance. A study is underway to identify sources of shot-to-shot variations which correlate with diode impedance collapse. The scope of this report is limited to data collected at 4.5-MV peak voltage and sources of variability which occur away from the diode, such as sheath electron emission and trajectories, variations in pulsed power, load and transmission line alignment, and different field shapers. We find no changes in the transmission line hardware, alignment, or hardware preparation methods which correlate with impedance collapse. However, in classifying good versus poor shots, we find that there is not a continuous spectrum of diode impedance behavior but that the good and poor shots can be grouped into two distinct impedance profiles. In poor shots, the sheath current in the load region falls from 16%–30% of the total current to less than 10%. This result will form the basis of a follow-up study focusing on the variability resulting from diode physics.

  20. Pumped shot noise in adiabatically modulated graphene-based double-barrier structures.

    Science.gov (United States)

    Zhu, Rui; Lai, Maoli

    2011-11-16

    Quantum pumping processes are accompanied by considerable quantum noise. Based on the scattering approach, we investigated the pumped shot noise properties in adiabatically modulated graphene-based double-barrier structures. It is found that compared with the Poisson processes, the pumped shot noise is dramatically enhanced where the dc pumped current changes flow direction, which demonstrates the effect of the Klein paradox.

  1. Pumped shot noise in adiabatically modulated graphene-based double-barrier structures

    Science.gov (United States)

    Zhu, Rui; Lai, Maoli

    2011-11-01

    Quantum pumping processes are accompanied by considerable quantum noise. Based on the scattering approach, we investigated the pumped shot noise properties in adiabatically modulated graphene-based double-barrier structures. It is found that compared with the Poisson processes, the pumped shot noise is dramatically enhanced where the dc pumped current changes flow direction, which demonstrates the effect of the Klein paradox.

  2. 77 FR 36272 - SunShot Prize: America's Most Affordable Rooftop

    Science.gov (United States)

    2012-06-18

    ...The Department of Energy (DOE) announces in this notice the release of the SunShot Prize: America's Most Affordable Rooftop Solar for public comment. Interested persons are encouraged to learn about the SunShot Prize: America's Most Affordable Rooftop rules at eere.energy.gov/solar/sunshot/prize.html.

  3. Investigations of shot reproducibility for the SMP diode at 4.5 MV.

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, Nichelle [National Security Technologies, LLC, Las Vegas, NV (United States); Crain, Marlon D. [National Security Technologies, LLC, Las Vegas, NV (United States); Droemer, Darryl W. [National Security Technologies, LLC, Las Vegas, NV (United States); Gignac, Raymond Edward [National Security Technologies, LLC, Las Vegas, NV (United States); Lare, Gregory A. [National Security Technologies, LLC, Las Vegas, NV (United States); Molina, Isidro [National Security Technologies, LLC, Las Vegas, NV (United States); Obregon, Rafael [National Security Technologies, LLC, Las Vegas, NV (United States); Smith, Chase C. [National Security Technologies, LLC, Las Vegas, NV (United States); Wilkins, Frank Lee [National Security Technologies, LLC, Las Vegas, NV (United States); Welch, Dale Robert [Voss Scientific, LLC, Albuquerque, NM (United States); Cordova, Steve Ray; Gallegos, M.; Johnston, Mark D.; Kiefer, Mark Linden; Leckbee, Joshua J.; Nielsen, Daniel Scott; Oliver, Bryan Velten; Renk, Timothy Jerome; Romero, Tobias; Webb, Timothy Jay; Ziska, Derek Raymond

    2013-11-01

    In experiments conducted on the RITS-6 accelerator, the SMP diode exhibits sig- ni cant shot-to-shot variability. Speci cally, for identical hardware operated at the same voltage, some shots exhibit a catastrophic drop in diode impedance. A study is underway to identify sources of shot-to-shot variations which correlate with diode impedance collapse. To remove knob emission as a source, only data from a shot series conducted with a 4.5-MV peak voltage are considered. The scope of this report is limited to sources of variability which occur away from the diode, such as power ow emission and trajectory changes, variations in pulsed power, dustbin and transmission line alignment, and di erent knob shapes. We nd no changes in the transmission line hardware, alignment, or hardware preparation methods which correlate with impedance collapse. However, in classifying good versus poor shots, we nd that there is not a continuous spectrum of diode impedance behavior but that the good and poor shots can be grouped into two distinct impedance pro les. This result forms the basis of a follow-on study focusing on the variability resulting from diode physics. 3

  4. Space based lidar shot pattern targeting strategies for small targets such as streams

    Science.gov (United States)

    Spiers, Gary D.

    2001-01-01

    An analysis of the effectiveness of four different types of lidar shot distribution is conducted to determine which is best for concentrating shots in a given location. A simple preemptive targeting strategy is found to work as adequately as a more involved dynamic strategy for most target sizes considered.

  5. The wear and corrosion resistance of shot peened-nitrided 316L austenitic stainless steel

    International Nuclear Information System (INIS)

    Hashemi, B.; Rezaee Yazdi, M.; Azar, V.

    2011-01-01

    Research highlights: → Shot peening-nitriding increased the wear resistance and surface hardness of samples. → This treatment improved the surface mechanical properties. → Shot peening alleviates the adverse effects of nitriding on the corrosion behavior. -- Abstract: 316L austenitic stainless steel was gas nitrided at 570 o C with pre-shot peening. Shot peening and nitriding are surface treatments that enhance the mechanical properties of surface layers by inducing compressive residual stresses and formation of hard phases, respectively. The structural phases, micro-hardness, wear behavior and corrosion resistance of specimens were investigated by X-ray diffraction, Vickers micro-hardness, wear testing, scanning electron microscopy and cyclic polarization tests. The effects of shot peening on the nitride layer formation and corrosion resistance of specimens were studied. The results showed that shot peening enhanced the nitride layer formation. The shot peened-nitrided specimens had higher wear resistance and hardness than other specimens. On the other hand, although nitriding deteriorated the corrosion resistance of the specimens, cyclic polarization tests showed that shot peening before the nitriding treatment could alleviate this adverse effect.

  6. Effects of Laser Peening, and Shot Peening, on Friction Stir Welding

    Science.gov (United States)

    Hatamleh, Omar; Hackel, Lloyd; Rankin, Jon; Truong, Chanh; Walter, Matt

    2006-01-01

    A viewgraph presentation describing the effects of laser peening and shot peening on friction stir welding is shown. The topics include: 1) Background; 2) Friction Stir Welding (FSW); 3) Microstructure; 4) Laser & Shot Peening; 5) Residual Stresses; 6) Tensile Behavior; 7) Fatigue Life & Surface Roughness; 8) Crack Growth; and 9) Benefits.

  7. The effect of court location and available time on the tactical shot selection of elite squash players.

    Science.gov (United States)

    Vučković, Goran; James, Nic; Hughes, Mike; Murray, Stafford; Sporiš, Goran; Perš, Janez

    2013-01-01

    No previous research in squash has considered the time between shots or the proximity of the ball to a wall, which are two important variables that influence shot outcomes. The aim of this paper was to analyse shot types to determine the extent to which they are played in different court areas and a more detailed analysis to determine whether the time available had an influence on the shot selected. Ten elite matches, contested by fifteen of the world's top right handed squash players (age 27 ± 3.2, height 1.81 ± 0.06 m, weight 76.3 ± 3.7 kg), at the men's World Team Championships were processed using the SAGIT/Squash tracking system with shot information manually added to the system. Results suggested that shot responses were dependent upon court location and the time between shots. When these factors were considered repeatable performance existed to the extent that one of two shots was typically played when there was limited time to play the shot (tactics affect shot selections. Key pointsPrevious research has suggested that a playing strategy, elements decided in advance of the match, may be evident for elite players by examining court location and preceding shot type, however these parameters alone are unlikely to be sufficient predictors.At present there is no known analysis in squash, or indeed in any of the racket sports, that has quantified the time available to respond to different shot types. An understanding of the time interval between shots and the movement characteristics of the player responding to different shots according to the court positions might facilitate a better understanding of the dynamics that determine shot selection.Some elements of a general playing strategy were evident e.g. predominately hitting to the back left of the court, but tactical differences in shot selection were also evident on the basis of court location and time available to play a shot.

  8. Upper body strength and power are associated with shot speed in men's ice hockey

    Directory of Open Access Journals (Sweden)

    Juraj Bežák

    2017-06-01

    Full Text Available Background: Recent studies that addressed shot speed in ice hockey have focused on the relationship between shot speed and variables such as a player's skills or hockey stick construction and its properties. There has been a lack of evidence that considers the relationship between shot speed and player strength, particularly in players at the same skill level. Objective: The aim of this study was to identify the relationship between maximal puck velocity of two shot types (the wrist shot and the slap shot and players' upper body strength and power. Methods: Twenty male professional and semi-professional ice hockey players (mean age 23.3 ± 2.4 years participated in this study. The puck velocity was measured in five trials of the wrist shot and five trials of the slap shot performed by every subject. All of the shots were performed on ice in a stationary position 11.6 meters in front of an electronic device that measures the speed of the puck. The selected strength and power variables were: muscle power in concentric contraction in the countermovement bench press with 40 kg and 50 kg measured with the FiTRODyne Premium device; bench press one-repetition maximum; and grip strength measured by digital hand dynamometer. Results: The correlations between strength/power variables and the puck velocity in the wrist shot and the slap shot ranged between .29-.72 and .16-.62, respectively. Puck velocities produced by wrist shots showed significant correlations with bench press muscle power with 40 kg (p = .004 and 50 kg (p < .001; and one-repetition maximum in bench press (p = .004. The slap shot puck velocity was significantly associated with bench press muscle power with 40 kg (p = .014 and 50 kg (p = .004. Conclusions: This study provides evidence that there are significant associations between shot speed and upper body strength and power.

  9. High human exposure to lead through consumption of birds hunted with lead shot

    International Nuclear Information System (INIS)

    Johansen, P.; Asmund, G.; Riget, F.

    2004-01-01

    Lead shot contaminates the edible parts of birds so that tolerable human lead intake is exceeded. - We assess lead contamination of Greenland seabirds killed with lead shot having studied thick-billed murre and common eider, the two most important species in the diet. The lead concentration is very high in meat of eiders killed with lead shot (mean 6.1 μg/g-wet wt, 95% CL 2.1-12). This level is about 44 times higher than in drowned eiders and eight times higher than in shot murres. Analyzing whole breasts instead of sub-samples reveals about seven times higher lead levels in birds' meat. We conclude that in some cases the lead intake by Greenland bird eaters will largely exceed the FAO/WHO tolerable lead intake guideline and that lead shot is a more important source of lead in the diet than previously estimated

  10. Mug shot exposure prior to lineup identification: interference, transference, and commitment effects.

    Science.gov (United States)

    Dysart, J E; Lindsay, R C; Hammond, R; Dupuis, P

    2001-12-01

    The effects of viewing mug shots on subsequent identification performance are as yet unclear. Two experiments used a live staged-crime paradigm to determine if interpolated eyewitness exposure to mug shots caused interference, unconscious transference, or commitment effects influencing subsequent lineup accuracy. Experiment 1 (N = 104) tested interference effects. Similar correct decision rates were obtained for the mug shot and no mug shot groups from both perpetrator-present and absent lineups. Experiment 2 (N = 132) tested for commitment and transference effects. Results showed that the commitment group made significantly more incorrect identifications than either the control or the transference group, which had similar false-identification rates. Commitment effects present a serious threat to identification accuracy from lineups following mug shot searches.

  11. Finite element modelling of coverage effects during shot peening of IN718

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, Marc; Hoffmeister, Juergen [Inst. fuer Werkstoffkunde I, Karlsruhe Inst. of Tech. (Germany); Schulze, Volker [Inst. fur Produktionstechnik, Karlsruhe Inst. of Tech. (Germany)

    2010-08-15

    Current 3D shot peening simulation models proposed in literature do not take into account coverage as a process parameter influencing the residual state after shot peening. In this study a classic approach, using an ordered dimple pattern, and a new approach, using a stochastic dimple pattern were tested to describe the correlation between coverage, the surface topography and the residual stress state. Model verification was conducted based on X-ray and confocal white light microscopy measurements on shot peened test specimens. The test material was age hardened IN718. Simulations showed that the dimple pattern and the impact order of the shots can have a strong influence on the calculated macroscopic residual stress state. The stochastic approach enabled a realistic prediction of the surface topography and the residual stress state for arbitrary values of coverage while the classic approach strongly underestimated the number of shot impacts needed to achieve a certain value of coverage. (orig.)

  12. Effect of shot peening process on fatigue behavior of an alloyed austempered ductile iron

    Directory of Open Access Journals (Sweden)

    Amir Sadighzadeh Benam

    2011-08-01

    Full Text Available Shot peening is one of the most common surface treatments to improve the fatigue behavior of metallic parts. In this study the effect of shot peening process on the fatigue behavior of an alloyed austempered ductile iron (ADI has been studied. Austempering heat treatment consisted of austenitizing at 875℃ for 90 min followed by austempering at three different temperatures of 320, 365 and 400℃. Rotating-bending fatigue test was carried out on samples after shot peening by 0.4 – 0.6 mm shots. XRD and SEM analysis, micro hardness and roughness tests were carried out to study the fatigue behavior of the samples. Results indicate that the fatigue strengths of samples austempered at 320, 365 and 400℃ are increased by 27.3%, 33.3% and 48.4%, respectively, after shot peening process.

  13. Design and Implementation of Video Shot Detection on Field Programmable Gate Arrays

    Directory of Open Access Journals (Sweden)

    Jharna Majumdar

    2012-09-01

    Full Text Available Video has become an interactive medium of communication in everyday life. The sheer volume of video makes it extremely difficult to browse through and find the required data. Hence extraction of key frames from the video which represents the abstract of the entire video becomes necessary. The aim of the video shot detection is to find the position of the shot boundaries, so that key frames can be selected from each shot for subsequent processing such as video summarization, indexing etc. For most of the surveillance applications like video summery, face recognition etc., the hardware (real time implementation of these algorithms becomes necessary. Here in this paper we present the architecture for simultaneous accessing of consecutive frames, which are then used for the implementation of various Video Shot Detection algorithms. We also present the real time implementation of three video shot detection algorithms using the above mentioned architecture on FPGA (Field Programmable Gate Arrays.

  14. Acceptance test procedure, 241-SY-101/241-C-106 shot loading system

    International Nuclear Information System (INIS)

    Ostrom, M.J.

    1994-01-01

    This Acceptance Test Procedure is for the 241-SY-101/241-C-106 Shot Loading System. The procedure will test the components of the Shot Loading System and its capability of adequately loading shot into the annular space of the Container. The loaded shot will provide shielding as required for transporting and storage of a contaminated pump after removal from the tank. This test serves as verification that the SLS is acceptable for use in the pump removal operations for Tanks 241-SY-101, 241-C-106 and 241-AY-102. The pump removal operation for these three tanks will be performed by two different organizations with different equipment, but the Shot Loading System will be compatible between the two operations

  15. On the residual stress modeling of shot-peened AISI 4340 steel: finite element and response surface methods

    Science.gov (United States)

    Asgari, Ali; Dehestani, Pouya; Poruraminaie, Iman

    2018-02-01

    Shot peening is a well-known process in applying the residual stress on the surface of industrial parts. The induced residual stress improves fatigue life. In this study, the effects of shot peening parameters such as shot diameter, shot speed, friction coefficient, and the number of impacts on the applied residual stress will be evaluated. To assess these parameters effect, firstly the shot peening process has been simulated by finite element method. Then, effects of the process parameters on the residual stress have been evaluated by response surface method as a statistical approach. Finally, a strong model is presented to predict the maximum residual stress induced by shot peening process in AISI 4340 steel. Also, the optimum parameters for the maximum residual stress are achieved. The results indicate that effect of shot diameter on the induced residual stress is increased by increasing the shot speed. Also, enhancing the friction coefficient magnitude always cannot lead to increase in the residual stress.

  16. AN ECOLOGICAL RISK ASSESSMENT OF LEAD SHOT EXPOSURE IN NON-WATERFOWL AVIAN SPECIES: UPLAND GAME BIRDS AND RAPTORS

    Science.gov (United States)

    There is increasing concern that birds in terrestrial ecosystems may be exposed to spent lead shot. Evidence exists that upland birds, particularly mourning doves (Zenaida macroura), ingest spent lead shot and that raptors ingest lead shot by consuming wounded game. Mortality, ne...

  17. Radiologically contaminated lead shot reuse at the Idaho National Engineering Laboratory (INEL)

    International Nuclear Information System (INIS)

    Heileson, W.M.; Grant, R.P.

    1995-01-01

    This project involved the utilization of radioactively contaminated lead shot located at the Radioactive Waste Management Complex (RWMC) for radiation shielding on a radioactive liquid process tank located at Argonne National Laboratory-West (ANL-W). The use of previously contaminated shot precludes the radioactive contamination of clean shot. With limited treatment and disposal options for contaminated lead shot, the reuse of lead for shielding is significant due to the inherent characteristic of becoming a mixed waste when radiologically contaminated. The INEL conducted a lead cleanup campaign in 1990. This was designed to ensure control of potential Resource Conservation and Recovery Act (RCRA) regulated waste. Contaminated lead from throughout the INEL, was containerized per the lead Waste Acceptance Criteria at the generator sites. Limited areas at the INEL are designated for mixed waste storage. As a result, some of the lead was stored at the RWMC in the air support weather shield (ASWS). This lead was contaminated with small amounts of fission product contamination. The lead was in the form of shot, brick, sheet, casks, and other various sized pieces. In 1993, ANL-W identified a need for lead shot to be used as shielding in a radioactive liquid waste storage and processing tank at the Fuel Cycle Facility (FCF). The contaminated lead used on this project had been in storage as mixed waste at the RWMC. This paper will focus on the processes and problems encountered to utilize the contaminated lead shot

  18. Subjective State, Blood Pressure, and Behavioral Control Changes Produced by an "Energy Shot"

    Science.gov (United States)

    Marczinski, Cecile A; Stamates, Amy L; Ossege, Julianne; Maloney, Sarah F; Bardgett, Mark E; Brown, Clifford J

    2014-06-01

    Background: Energy drinks and energy shots are popular consumer beverages that are advertised to increase feelings of alertness. Typically, these products include high levels of caffeine, a mild psychostimulant drug. The scientific evidence demonstrating the specific benefits of energy products to users in terms of subjective state and objective performance is surprisingly lacking. Moreover, there are rising health concerns associated with the use of these products. Therefore, the purpose of this study was to investigate the acute effects of a popular energy shot (5-Hour Energy ® ) on subjective and objective measures that were assessed hourly for 6 hours following consumption. Methods: Participants ( n =14) completed a three-session study where they received the energy shot, a placebo control, and no drink. Following dose administration, participants completed subjective Profile of Mood States ratings hourly for 6 hours. Participants also repeatedly completed a behavioral control task (the cued go/no-go task) and provided blood pressure and pulse rate readings at each hour. Results: Consumption of the energy shot did improve subjective state, as measured by increased ratings of vigor and decreased ratings of fatigue. However, the energy shot did not alter objective performance, which worsened over time. Importantly, the energy shot elevated both systolic and diastolic blood pressure. Conclusions: Consumption of one energy shot may only result in modest benefits to subjective state. Individuals with preexisting hypertension or other medical conditions should be cautious about using these new consumer products.

  19. Spectrometer for shot-to-shot photon energy characterization in the multi-bunch mode of the free electron laser at Hamburg

    International Nuclear Information System (INIS)

    Palutke, S.; Wurth, W.; Gerken, N. C.; Mertens, K.; Klumpp, S.; Martins, M.; Mozzanica, A.; Schmitt, B.; Wunderer, C.; Graafsma, H.; Meiwes-Broer, K.-H.

    2015-01-01

    The setup and first results from commissioning of a fast online photon energy spectrometer for the vacuum ultraviolet free electron laser at Hamburg (FLASH) at DESY are presented. With the use of the latest advances in detector development, the presented spectrometer reaches readout frequencies up to 1 MHz. In this paper, we demonstrate the ability to record online photon energy spectra on a shot-to-shot base in the multi-bunch mode of FLASH. Clearly resolved shifts in the mean wavelength over the pulse train as well as shot-to-shot wavelength fluctuations arising from the statistical nature of the photon generating self-amplified spontaneous emission process have been observed. In addition to an online tool for beam calibration and photon diagnostics, the spectrometer enables the determination and selection of spectral data taken with a transparent experiment up front over the photon energy of every shot. This leads to higher spectral resolutions without the loss of efficiency or photon flux by using single-bunch mode or monochromators

  20. Robust shot-noise measurement for continuous-variable quantum key distribution

    Science.gov (United States)

    Kunz-Jacques, Sébastien; Jouguet, Paul

    2015-02-01

    We study a practical method to measure the shot noise in real time in continuous-variable quantum key distribution systems. The amount of secret key that can be extracted from the raw statistics depends strongly on this quantity since it affects in particular the computation of the excess noise (i.e., noise in excess of the shot noise) added by an eavesdropper on the quantum channel. Some powerful quantum hacking attacks relying on faking the estimated value of the shot noise to hide an intercept and resend strategy were proposed. Here, we provide experimental evidence that our method can defeat the saturation attack and the wavelength attack.

  1. Finite element analysis for prediction of the residual stresses induced by shot peening II

    International Nuclear Information System (INIS)

    Kim, Cheol; Seok, Chang Sung; Yang, Won Ho; Ryu, Myung Hai

    2002-01-01

    Shot peening is a surface impact treatment widely used to improve the performance of metal parts and welded details subjected to fatigue loading, contact fatigue, stress corrosion and other damage mechanisms. The better performance of the peened parts is mainly due to the residual stresses resulting from the plastic deformation of the surface layers of the material caused by the impact of the shot. In this paper the simulation technique is applied to predict the magnitude and distribution of the residual stress and plastic deformation caused by shot peening with the help of finite element analysis

  2. Effects of shot peening on the residual stress of welded SS400 steel

    International Nuclear Information System (INIS)

    Lee, Jong Man; Kim, Tae Hyung; Cheong, Seong Kyun; Lee, Seung Ho

    2002-01-01

    The fatigue life of structures is usually determined by welding zone. The tensile residual stress, which is induced by welding, reduces the fatigue life and fatigue strength of welded structures. If we remove the tensile residual stress or induce the compressive residual stress, the fatigue life of welded structures will be improved. The change of hardness and compressive residual stress of welded zone after shot peening was investigated in this paper. The results show that the hardness was increased by shot peening. The residual stress was reduced by shot peening

  3. Shot noise as a probe of spin-correlated transport through single atoms

    Science.gov (United States)

    Pradhan, S.; Fransson, J.

    2018-03-01

    We address the shot noise in the tunneling current through a local spin, pertaining to recent experiments on magnetic adatoms and single molecular magnets. We show that both uncorrelated and spin-correlated scattering processes contribute vitally to the noise spectrum. The spin-correlated scattering processes provide an additional contribution to the Landauer-Büttiker shot noise expression, accounting for correlations between the tunneling electrons and the localized spin moment. By calculating the Fano factor, we show that both super- and sub-Poissonian shot noise can be described within our approach. Our theory provides transparent insights into noise spectroscopy, consistent with recent experiments using local probing techniques on magnetic atoms.

  4. "Heart Shots": a classroom activity to instigate active learning.

    Science.gov (United States)

    Abraham, Reem Rachel; Vashe, Asha; Torke, Sharmila

    2015-09-01

    The present study aimed to provide undergraduate medical students at Melaka Manipal Medical College (Manipal Campus), Manipal University, in Karnataka, India, an opportunity to apply their knowledge in cardiovascular concepts to real-life situations. A group activity named "Heart Shots" was implemented for a batch of first-year undergraduate students (n = 105) at the end of a block (teaching unit). Students were divided into 10 groups each having 10-11 students. They were requested to make a video/PowerPoint presentation about the application of cardiovascular principles to real-life situations. The presentation was required to be of only pictures/photos and no text material, with a maximum duration of 7 min. More than 95% of students considered that the activity helped them to apply their knowledge in cardiovascular concepts to real-life situations and understand the relevance of physiology in medicine and to revise the topic. More than 90% of students agreed that the activity helped them to apply their creativity in improving their knowledge and to establish a link between concepts rather than learning them as isolated facts. Based on the feedback, we conclude that the activity was student centered and that it facilitated learning. Copyright © 2015 The American Physiological Society.

  5. ANALYSIS OF DIFFERENT FORMS OF SHOTS IN FOOTBALL

    Directory of Open Access Journals (Sweden)

    Miroslav Radoman

    2010-09-01

    Full Text Available The area of technical-tactical activities is very interesting and unexplored, especially because the game from year to year changes faster. The aim of this research is to perform analysis of different forms of shots in football (in the official statistics and their association with outcomes of football matches at the World Cup 2006. in Germany (FIFA World Cup Germany 2006.. The sample consists of observations of 64 games played at the World Cup 2006. in Germany. Sample characteristics are elements of games that are leading the official statistics, which is promoted for all FIFA competitions that take place under its auspices, including the World Championships. Of five elements for analysis was selected four. Based on the analysis set forth can be concluded that the team winning the game stands out significantly in all analyzed characteristics in relation to the game the team with a score draw or a defeat where the difference is less. All teams that have achieved the victory had offensive tactics or were technically dominant in relation to the opponent.

  6. Ship Detection Using Transfer Learned Single Shot Multi Box Detector

    Directory of Open Access Journals (Sweden)

    Nie Gu-Hong

    2017-01-01

    Full Text Available Ship detection in satellite images is a challenging task. In this paper, we introduce a transfer learned Single Shot MultiBox Detector (SSD for ship detection. To this end, a state-of-the-art object detection model pre-trained from a large number of natural images was transfer learned for ship detection with limited labeled satellite images. To the best of our knowledge, this could be one of the first studies which introduce SSD into ship detection on satellite images. Experiments demonstrated that our method could achieve 87.9% AP at 47 FPS using NVIDIA TITAN X. In comparison with Faster R-CNN, 6.7% AP improvement could be achieved. Effects of the observation resolution has also been studied with the changing input sizes among 300 × 300, 600 × 600 and 900 × 900. It has been noted that the detection accuracy declined sharply with the decreasing resolution that is mainly caused by the missing small ships.

  7. SunShot Initiative: Making Solar Energy Affordable for All Americans (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2013-10-01

    Through SunShot, DOE supports efforts by private companies, universities, and national laboratories to drive down the cost of solar electricity to $0.06 per kilowatt-hour, making solar energy affordable for more American families and businesses.

  8. 77 FR 58114 - SunShot Prize: Race to the Rooftop

    Science.gov (United States)

    2012-09-19

    ...This notice announces the release of the SunShot Prize: Race to the Rooftop competition. This competition offers $10 million in prizes to those who can lower the non-hardware installation cost of rooftop solar energy systems.

  9. Shot Boundary Detection in Soccer Video using Twin-comparison Algorithm and Dominant Color Region

    Directory of Open Access Journals (Sweden)

    Matko Šarić

    2008-06-01

    Full Text Available The first step in generic video processing is temporal segmentation, i.e. shot boundary detection. Camera shot transitions can be either abrupt (e.g. cuts or gradual (e.g. fades, dissolves, wipes. Sports video is one of the most challenging domains for robust shot boundary detection. We proposed a shot boundary detection algorithm for soccer video based on the twin-comparison method and the absolute difference between frames in their ratios of dominant colored pixels to total number of pixels. With this approach the detection of gradual transitions is improved by decreasing the number of false positives caused by some camera operations. We also compared performances of our algorithm and the standard twin-comparison method.

  10. The importance of reliability to the SunShot Initiative (Presentation Recording)

    Science.gov (United States)

    Jones-Albertus, Rebecca

    2015-09-01

    The U.S. Department of Energy's SunShot Initiative was launched in 2011 to make subsidy-free solar electricity cost competitive with conventional energy sources by the end of the decade. Research in reliability can play a major role in realizing the SunShot goal of 0.06/kWh. By improving photovoltaic module lifetime and reducing degradation rates, a system's lifetime energy output is increased. Increasing confidence in photovoltaic performance prediction can lower perceived investment risk and thus the cost of capital. Accordingly, in 2015, SunShot expects to award more than $40 million through its SunShot National Laboratory Multiyear Partnership (SuNLaMP) and Physics of Reliability: Evaluating Design Insights for Component Technologies in Solar (PREDICTS) 2 funding programs, for research into reliability topics such as determining acceleration factors, modeling degradation rates and failure mechanisms, improving predictive performance models, and developing new test methods and instrumentation.

  11. Shot noise and electronic properties in the inversion-symmetric Weyl semimetal resonant structure

    Science.gov (United States)

    Yang, Yanling; Bai, Chunxu; Xu, Xiaoguang; Jiang, Yong

    2018-02-01

    Using the transfer matrix method, the authors combine the analytical formula with numerical calculation to explore the shot noise and conductance of massless Weyl fermions in the Weyl semimetal resonant junction. By varying the barrier strength, the structure of the junction, the Fermi energy, and the crystallographic angle, the shot noise and conductance can be tuned efficiently. For a quasiperiodic superlattice, in complete contrast to the conventional junction case, the effect of the disorder strength on the shot noise and conductance depends on the competition of classical tunneling and Klein tunneling. Moreover, the delta barrier structure is also vital in determining the shot noise and conductance. In particular, a universal Fano factor has been found in a single delta potential case, whereas the resonant structure of the Fano factor perfectly matches with the number of barriers in a delta potential superlattice. These results are crucial for engineering nanoelectronic devices based on this topological semimetal material.

  12. Student Hands-On Training (SHOT) Workshop Summer 2003 and 2004

    National Research Council Canada - National Science Library

    Koehler, Chris

    2004-01-01

    .... The objective of SHOT I AND II workshops are to provide these new students exposure to some of the basics of spacecraft construction, the teamwork and coordination involved, as well as the challenges...

  13. Maximum one-shot dissipated work from Rényi divergences

    Science.gov (United States)

    Yunger Halpern, Nicole; Garner, Andrew J. P.; Dahlsten, Oscar C. O.; Vedral, Vlatko

    2018-05-01

    Thermodynamics describes large-scale, slowly evolving systems. Two modern approaches generalize thermodynamics: fluctuation theorems, which concern finite-time nonequilibrium processes, and one-shot statistical mechanics, which concerns small scales and finite numbers of trials. Combining these approaches, we calculate a one-shot analog of the average dissipated work defined in fluctuation contexts: the cost of performing a protocol in finite time instead of quasistatically. The average dissipated work has been shown to be proportional to a relative entropy between phase-space densities, to a relative entropy between quantum states, and to a relative entropy between probability distributions over possible values of work. We derive one-shot analogs of all three equations, demonstrating that the order-infinity Rényi divergence is proportional to the maximum possible dissipated work in each case. These one-shot analogs of fluctuation-theorem results contribute to the unification of these two toolkits for small-scale, nonequilibrium statistical physics.

  14. Time to Get Your Seasonal Flu Shot | NIH MedlinePlus the Magazine

    Science.gov (United States)

    ... page please turn JavaScript on. Feature: Flu Season Time to Get Your Seasonal Flu Shot Past Issues / ... able to infect others for an even longer time. How serious is the flu? Certain people are ...

  15. Control of lead solubility in soil contaminated with lead shot: Effect of soil pH

    International Nuclear Information System (INIS)

    Rooney, Corinne P.; McLaren, Ronald G.; Condron, Leo M.

    2007-01-01

    An incubation experiment was carried out to assess the rate of oxidation of Pb shot and subsequent transfer of Pb to the soil under a range of soil pH conditions. Lead shot corrosion was rapid, so that soil solution and fine earth ( 3 (CO 3 ) 2 (OH) 2 ), developed in crusts surrounding individual Pb pellets. However, irrespective of pH, Pb 2+ activities in the soil solutions, modelled using WHAM 6, were much lower than would be the case if they were controlled by the solubility of the dominant Pb compounds present in the Pb shot crust material. In contrast, modelling of soil solid-solution phase distribution of Pb, again using WHAM 6, suggested that, at least during the 24 months of the study, soil solution Pb concentrations were more likely to be controlled by sorption of Pb by the soil solid phase. - Sorption processes control Pb 2+ ion activity in soils contaminated with Pb shot

  16. SunShot 2030 for Photovoltaics (PV): Envisioning a Low-Cost PV Future

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Wesley J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Frew, Bethany A [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Gagnon, Pieter J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Richards, James [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Sun, Yinong [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Zuboy, Jarrett; Woodhouse, Michael A [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Margolis, Robert M [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-10-01

    This presentation summarizes the findings from the report 'SunShot 2030 for Photovoltaics (PV): Envisioning a Low-cost PV Future.' This presentation was given as a webinar on September 26, 2017.

  17. Diphtheria and the Vaccine (Shot) to Prevent It: Information for Parents

    Science.gov (United States)

    ... PARENTS | DISEASES and the VACCINES THAT PREVENT THEM | Diphtheria and the Vaccine (Shot) to Prevent It Last ... April 2017 The best way to protect against diphtheria is by getting the diphther ia-tet anus- ...

  18. Automatic video shot boundary detection using k-means clustering and improved adaptive dual threshold comparison

    Science.gov (United States)

    Sa, Qila; Wang, Zhihui

    2018-03-01

    At present, content-based video retrieval (CBVR) is the most mainstream video retrieval method, using the video features of its own to perform automatic identification and retrieval. This method involves a key technology, i.e. shot segmentation. In this paper, the method of automatic video shot boundary detection with K-means clustering and improved adaptive dual threshold comparison is proposed. First, extract the visual features of every frame and divide them into two categories using K-means clustering algorithm, namely, one with significant change and one with no significant change. Then, as to the classification results, utilize the improved adaptive dual threshold comparison method to determine the abrupt as well as gradual shot boundaries.Finally, achieve automatic video shot boundary detection system.

  19. Experimental and Numerical Analysis of Microstructures and Stress States of Shot-Peened GH4169 Superalloys

    Science.gov (United States)

    Hu, Dianyin; Gao, Ye; Meng, Fanchao; Song, Jun; Wang, Rongqiao

    2018-04-01

    Combining experiments and finite element analysis (FEA), a systematic study was performed to analyze the microstructural evolution and stress states of shot-peened GH4169 superalloy over a variety of peening intensities and coverages. A dislocation density evolution model was integrated into the representative volume FEA model to quantitatively predict microstructural evolution in the surface layers and compared with experimental results. It was found that surface roughness and through-depth residual stress profile are more sensitive to shot-peening intensity compared to coverage due to the high kinetic energy involved. Moreover, a surface nanocrystallization layer was discovered in the top surface region of GH4169 for all shot-peening conditions. However, the grain refinement was more intensified under high shot-peening coverage, under which enough time was permitted for grain refinement. The grain size gradient predicted by the numerical framework showed good agreement with experimental observations.

  20. Influence of the shot-peening treatment on the CRF gearing behaviour

    International Nuclear Information System (INIS)

    Molinie, D.; Lemaire, E.; Randrianarivo, L.; Dorier, C.

    1998-01-01

    Surface damage are observed in service on CRF case-hardened cases. Such damage is like surface fatigue which appears in the form of frosting and can come to a micro-spalling or even a spalling damage. Survey and studies realised on gears affected by such damage, led EDF and the manufacturer to search for appropriated solutions since 1985 (optimisation of the gear bottom profile, care of the grinding and the thermochemical processing, use of oils with higher viscosity). Simulations on a running wheel device can reproduce the meshing conditions on simplified specimen. The aim is to study the influence of residual stresses following a severe grinding and shot peening treatments. An empiric selection was realised among different shot peening treatments. Endurance tests are realised on case-hardened gears with or without shot-peening treatments. Compared with standard grinded gears, it appears that the shot-peening selected increases up to 40% the gear lifetime till extended spalling. (authors)

  1. Berry phase and shot noise for spin-polarized and entangled electrons

    International Nuclear Information System (INIS)

    Wang Pei; Tang Weihua; Lu Dinghui; Jiang Lixia; Zhao Xuean

    2007-01-01

    Shot noise for entangled and spin-polarized states in a four-probe geometric setup has been studied by adding two rotating magnetic fields in an incoming channel. Our results show that the noise power oscillates as the magnetic fields vary. The singlet, entangled triplet and polarized states can be distinguished by adjusting the magnetic fields. The Berry phase can be derived by measuring the shot noise power

  2. Gun Shot Wound to the Chest of a Military Working Dog

    Science.gov (United States)

    2009-06-01

    special care ought to be taken when either human or dog is on isolation precautions. Also, animals without airway compromise should be muzzled , as...Gun Shot Wound to Chest of Military Working Dog Military Medicine Radiology Corner, Volume 174, June, 2009 Radiology Corner Gun Shot Wound to...the Chest of a Military Working Dog Guarantor: 2LT Meghan Galer, MSC, USA1 Contributors: 2LT Meghan Galer, MSC, USA1; Donna Magid, MD, MEd2; Les

  3. Kinematic Differences between Set- and Jump-Shot Motions in Basketball

    OpenAIRE

    Hiroki Okubo; Mont Hubbard

    2018-01-01

    Shooting arm motions at release in one-hand set and jump basketball shots have been analyzed using a kinematic model. Set and jump shots are classified by the vertical velocity and acceleration of the shooter’s shooting-side shoulder at release. The two-dimensional three-segment model includes the vertical shooting-side shoulder velocity and acceleration. Numerical simulation investigates the effect of shoulder motion. Release backspin angular velocity can be described as a function of the ve...

  4. Microscopic analysis of effect of shot peening on corrosion fatigue behavior of aluminum alloy

    International Nuclear Information System (INIS)

    Kim, Jong Cheon; Cheong, Seong Kyun

    2012-01-01

    The object of this study considers corrosion fatigue improvement of 7075-T6 aluminum by using shot peening treatment on 3.5% NaCl solution at room temperature. Aluminum alloy is generally used in aerospace structural components because of the light weight and high strength characteristics. Many studies have shown that an aluminum alloy can be approximately 50% lighter than other materials. Mostly, corrosion leads to earlier fatigue crack propagation under tensile conditions and severely reduces the life of structures. Therefore, the technique to improve material resistance to corrosion fatigue is required. Shot peening technology is widely used to improve fatigue life and other mechanical properties by induced compressive residual stress. Even the roughness of treated surface causes pitting corrosion, the compressive residual stress, which is induced under the surface layer of material by shot peening, suppersses the corrosion and increases the corrosion resistance. The experimental results for shot peened specimens were compared with previous work for non treated aluminum alloy. The results show that the shot peening treatment affects the corrosion fatigue improvement of aluminum alloys and the induced compressive residual stress by shot peening treatment improves the resistance to corrosion fatigue

  5. Shot-peening of carbonitrided steel: influence of the process on the mechanical state

    Directory of Open Access Journals (Sweden)

    François M.

    2010-06-01

    Full Text Available Residual stresses have a significant role in affecting engineering properties of materials and shot peening process is an effective production technique to ensure required residual stress levels. This paper presents an analysis of an orthogonal design of experiment to establish an empirical relationship between main parameters of shot peening process and residual stress profiles for a carbonitrided steel. The hardening / softening evolution of the material is followed using hardness and diffraction peak width. Four critical peening parameters, i.e. shot size, incident angle, exposure time, airblast pressure, have been chosen and the range of peening conditions are established by using the Taguchi technique. In this study, a shot velocity measurement system is used to obtain the on-line velocity during the peening process and the relationship between the maximum compressive residual stresses and the shot velocity is also developed. Analysis of the experimental data showed that it is possible to optimize the shot peening process by an effective control of process parameters.

  6. Use and Perceptions of Caffeinated Energy Drinks and Energy Shots in Canada.

    Science.gov (United States)

    Wiggers, Danielle; Reid, Jessica L; White, Christine M; Hammond, David

    2017-12-01

    In Canada, energy drinks and energy shots are currently classified and regulated differently (food and drugs versus natural health products, respectively), on the assumption that they are used and perceived differently. The current study examined potential differences in use and perceptions of energy drinks and shots. An online survey was conducted in 2015 using a national commercial online panel of youth and young adults aged 12-24 years (n=2,040 retained for analysis in 2016). Participants were randomized to view an image of an energy shot or drink, and were asked about 14 potential reasons for using the product. Past consumption of each product was also assessed. Chi-square and t-tests were conducted to examine differences in use and perceptions between products. Overall, 15.6% of respondents reported using both energy shots and drinks. Of all respondents, ordering of the reasons for use of each product was comparable. Despite differences in prevalence of ever-use of energy shots and drinks, consumption patterns and perceived reasons for using the products are similar. The findings provide little support for regulating energy shots differently than energy drinks. Copyright © 2017 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  7. A Study on the Microstructural Evolution of a Low Alloy Steel by Different Shot Peening Treatments

    Directory of Open Access Journals (Sweden)

    Juan González

    2018-03-01

    Full Text Available Recent studies have shown that severe shot peening can be categorized as a severe plastic deformation surface treatment that is able to strongly modify the microstructure of the surface layer of materials, by both increasing the dislocation density and introducing a large number of defects that define new grain boundaries and form ultrafine structure. In this work, conventional shot peening and severe shot peening treatments were applied to 39NiCrMo3 steel samples. The samples were characterized in terms of microstructure, surface roughness, microhardness, residual stresses, and surface work-hardening as a function of surface coverage. Particular attention was focused on the analysis of the microstructure to assess the evolution of grain size from the surface to the inner material to capture the gradient microstructure. Severe shot peening proved to cause a more remarkable improvement of the general mechanical characteristics compared to conventional shot peening; more significant improvement was associated with the microstructural alteration induced by the treatment. Our datas provide a detailed verification of the relationship between shot peening treatment parameters and the microstructure evolution from the treated surface to the core material.

  8. Evaluation of the 1Shot Phantom dedicated to the mammography system using FCR

    International Nuclear Information System (INIS)

    Nagashima, Chieko; Uchiyama, Nachiko; Moriyama, Noriyuki; Nagata, Mio; Kobayashi, Hiroyuki; Sankoda, Katsuhiro; Saotome, Shigeru; Tagi, Masahiro; Kusunoki, Tetsurou

    2009-01-01

    Currently daily quality control (QC) tests for mammography systems are generally evaluated by using visual analysis phantoms, which of course means subjective measurement. In our study, however, we evaluated a novel digital phantom, the 1Shot Phantom M plus (1Shot Phantom), together with automatic analysis software dedicated for mammography systems using Fuji computed radiography (FCR). The digital phantom enables objective evaluation by providing for actual physical measurement rather than subjective visual assessment. We measured contrast to noise ratio (CNR), image receptor homogeneity, missed tissue at chest wall side, modulation transfer function (MTF), and geometric distortion utilizing the 1Shot Phantom. We then compared the values obtained using the 1Shot Phantom with values obtained from the European guidelines and International Electrotechnical Commission (IEC) standards. In addition, we evaluated the convenience of using the digital phantom. The values utilizing the 1Shot Phantom and those from the European guidelines and IEC standards were consistent, but the QC tests for the European guidelines and IEC standards methods took about six hours while the same QC tests using the 1Shot Phantom took 10 minutes or less including exposure of the phantom image, measurement, and analysis. In conclusion, the digital phantom and dedicated software proved very useful and produced improved analysis for mammography systems using FCR in clinical daily QC testing because of their objectivity and substantial time-saving convenience. (author)

  9. Microscopic analysis of effect of shot peening on corrosion fatigue behavior of aluminum alloy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Cheon; Cheong, Seong Kyun [Seoul Nat' l Univ. of Science and Technology, Seoul (Korea, Republic of)

    2012-11-15

    The object of this study considers corrosion fatigue improvement of 7075-T6 aluminum by using shot peening treatment on 3.5% NaCl solution at room temperature. Aluminum alloy is generally used in aerospace structural components because of the light weight and high strength characteristics. Many studies have shown that an aluminum alloy can be approximately 50% lighter than other materials. Mostly, corrosion leads to earlier fatigue crack propagation under tensile conditions and severely reduces the life of structures. Therefore, the technique to improve material resistance to corrosion fatigue is required. Shot peening technology is widely used to improve fatigue life and other mechanical properties by induced compressive residual stress. Even the roughness of treated surface causes pitting corrosion, the compressive residual stress, which is induced under the surface layer of material by shot peening, suppersses the corrosion and increases the corrosion resistance. The experimental results for shot peened specimens were compared with previous work for non treated aluminum alloy. The results show that the shot peening treatment affects the corrosion fatigue improvement of aluminum alloys and the induced compressive residual stress by shot peening treatment improves the resistance to corrosion fatigue.

  10. Kinematic Differences between Set- and Jump-Shot Motions in Basketball

    Directory of Open Access Journals (Sweden)

    Hiroki Okubo

    2018-02-01

    Full Text Available Shooting arm motions at release in one-hand set and jump basketball shots have been analyzed using a kinematic model. Set and jump shots are classified by the vertical velocity and acceleration of the shooter’s shooting-side shoulder at release. The two-dimensional three-segment model includes the vertical shooting-side shoulder velocity and acceleration. Numerical simulation investigates the effect of shoulder motion. Release backspin angular velocity can be described as a function of the vertical shoulder acceleration and the vertical fingertip acceleration relative to the shoulder. For proper backspin, jump shots require large vertical fingertip acceleration relative to the shoulder. The upward shoulder speed at release contributes to the vertical fingertip velocity relative to the shoulder for a given desired ball release speed, angle and backspin. On the other hand, upward shoulder motion does not contribute to the horizontal direction. As horizontal shot distance increases, upper arm angular speed also increases to produce the ball release conditions. Ball release with upward shoulder speed reduces the magnitudes of the upper arm, forearm and hand angular velocities. All these facts imply that the shooting arm motion in the jump shot is different from that of the set shot.

  11. Magnetic Resonance Imaging Including Magnetic Resonance Cholangiopancreatography for Tumor Localization and Therapy Planning in Malignant Hilar Obstructions

    International Nuclear Information System (INIS)

    Haenninen, E.L.

    2005-01-01

    PURPOSE: To assess image quality and overall accuracy of magnetic resonance imaging (MRI), including two magnetic cholangiopancreatography (MRCP) techniques, for the diagnostics and preoperative work-up of malignant hilar obstructions. MATERIAL AND METHODS: Thirty-one patients with malignant hilar obstructions (hilar cholangiocarcinoma, n=30; hepatocellular carcinoma, n=1) received MRCP by two techniques (single-shot thick-slab and multisection thin-slice MRCP) and unenhanced and contrast material-enhanced MRI. MR assessment included the evaluation of image quality and visualization of bile ducts (5-point scale), and the classification of tumor status. MR results were subsequently correlated with the results from surgery and pathology. RESULTS: The maximum intensity projections of multisection thin-slice MRCP had significantly more artifacts compared to MRCP in the single-shot thick-slab technique, and overall image quality of single-shot thick-slab MRCP was rated significantly superior compared to multisection thin-slice MRCP (4.4 ± 0.7 and 4.1 ± 0.9, respectively). Moreover, ductal visualization of different parts of the biliary system was rated superior with single-shot thick-slab MRCP. In contrast, the original data from multisection thin slice MRCP facilitated visualization of periductal lesions and adjacent structures. Overall MR accuracy for the assessment of tumor status, periductal infiltration, and lymph node metastases was 90%, 87%, and 66%, respectively. CONCLUSION: For evaluation of malignant hilar obstructions, MRCP by the single-shot thick-slab technique had superior image quality and fewer artifacts; in contrast, besides sole biliary visualization, multisection MRCP depicted complementary adjacent parenchymal and periductal structures. We therefore recommend MRI, with a combination of both MRCP techniques, for the diagnostic work-up and therapy planning of malignant hilar obstructions

  12. Disorganized junior doctors fail the MRCP (UK).

    Science.gov (United States)

    Stanley, Adrian G; Khan, Khalid M; Hussain, Walayat; Tweed, Michael

    2006-02-01

    Career progression during undergraduate and early postgraduate years is currently determined by successfully passing examinations. Both academic factors (secondary school examination results, learning style and training opportunities) and non-academic factors (maturity, ethnic origin, gender and motivation) have been identified as predicting examination outcome. Few studies have examined organization skills. Disorganized medical students are more likely to perform poorly in end-of-year examinations but this observation has not been examined in junior doctors. This study asked whether organization skills relate to examination outcome amongst junior doctors taking the clinical Part II examination for the Membership of the Royal College of Physicians (Practical Assessment of Clinical Examination Skills). The study was conducted prospectively at four consecutive clinical courses that provided clinical teaching and practice to prepare trainees for the examination. Arrival time at registration for the course was the chosen surrogate for organization skills. Trainees were advised that they should arrive promptly at 8.00 a.m. for registration and it was explained that the course would start at 8.30 a.m. Recorded arrival times were compared with the pass lists published by the Royal College of Physicians. The mean arrival time was 8.17 a.m. A total of 81 doctors (53.3%) passed the examination with a mean arrival time of 8.14 a.m. However, 71 doctors failed the exam and arrived, on average, six minutes later than doctors who passed (p?=?0.006). Better-prepared junior doctors were more likely to pass the final examination. Arriving on time represents a composite of several skills involved in the planning of appropriate travel arrangements and is therefore a valid marker of organization skills and preparation. This novel study has shown that good time-keeping skills are positively associated with examination outcome.

  13. 3-D analysis of fatigue crack behaviour in a shot peened steam turbine blade material

    Energy Technology Data Exchange (ETDEWEB)

    He, B.Y., E-mail: Binyan.he@soton.ac.uk [Engineering Materials, Faculty of Engineering and the Environment, University of Southampton, Southampton SO17 1BJ (United Kingdom); Katsamenis, O.L. [muVIS X-ray Imaging Centre, Faculty of Engineering and the Environment, University of Southampton, Southampton SO17 1BJ (United Kingdom); Mellor, B.G.; Reed, P.A.S. [Engineering Materials, Faculty of Engineering and the Environment, University of Southampton, Southampton SO17 1BJ (United Kingdom)

    2015-08-26

    Serial mechanical sectioning and high resolution X-ray tomography have been used to study the three-dimensional morphology of small fatigue cracks growing in a 12 Cr tempered martensitic steam turbine blade material. A range of surface conditions has been studied, namely polished and shot peened (with varying levels of intensity). In the polished (unpeened) condition, inclusions (alumina and manganese sulphide) played an important role in initiating and controlling early fatigue crack behaviour. When fatigue cracks initiated from an alumina stringer, the crack morphology was normally dominated by single stringers, which were always in the centre of the fatigue crack, indicating its primary role in initiation. Manganese sulphide inclusion groups however seemed to dominate and affect the crack path along both the surface and depth crack growth directions. The more intensely shot peened condition did not however evidence inclusion or stringer affected fatigue crack initiation or growth behaviour; sub-surface crack coalescence being clearly observed by both serial sectioning and computed tomography (CT) imaging techniques at a depth of about 150–180 μm. These sub-surface crack coalescences can be linked to both the extent of the compressive residual stress as well as the depth of the plastic deformation arising from the intense shot peening process. Shot peening appears to provide a different defect population that initiates fatigue cracks and competes with the underlying metallurgical defect populations. The most beneficial shot peening process would in this case appear to “deactivate” the original metallurgical defect population and substitute a known defect distribution from the shot peening process from which fatigue cracks grow rather slowly in the strain hardened surface layer which also contains compressive residual stresses. A benefit to fatigue life in bending, even under Low Cycle Fatigue (LCF) conditions, has been observed in these tests if a

  14. Numerical simulation of the shot peening process under previous loading conditions

    International Nuclear Information System (INIS)

    Romero-Ángeles, B; Urriolagoitia-Sosa, G; Torres-San Miguel, C R; Molina-Ballinas, A; Benítez-García, H A; Vargas-Bustos, J A; Urriolagoitia-Calderón, G

    2015-01-01

    This research presents a numerical simulation of the shot peening process and determines the residual stress field induced into a component with a previous loading history. The importance of this analysis is based on the fact that mechanical elements under shot peening are also subjected to manufacturing processes, which convert raw material into finished product. However, material is not provided in a virgin state, it has a previous loading history caused by the manner it is fabricated. This condition could alter some beneficial aspects of the residual stress induced by shot peening and could accelerate the crack nucleation and propagation progression. Studies were performed in beams subjected to strain hardening in tension (5ε y ) before shot peening was applied. Latter results were then compared in a numerical assessment of an induced residual stress field by shot peening carried out in a component (beam) without any previous loading history. In this paper, it is clearly shown the detrimental or beneficial effect that previous loading history can bring to the mechanical component and how it can be controlled to improve the mechanical behavior of the material

  15. Characteristics of magnetically insulated diode in a multi-shot operation

    Energy Technology Data Exchange (ETDEWEB)

    Chishiro, E; Masugata, K; Yatsui, K [Nagaoka Univ. of Technology (Japan). Laboratory of Beam Technology

    1997-12-31

    The beam characteristics in a multi-shot operation were evaluated. The MID utilized in the experiment is a racetrack type diode, where flat anode and cathode electrodes are utilized. On the anode, a polyethylene sheet of 1 mm thickness is attached as an ion source. The MID is successively operated without breaking the vacuum. An ion current density (J{sub i}) of 350 A/cm{sup 2} is observed at the first shot when the diode gap is 5 mm. The value decreases with increasing number of shots and at the 7th shot, J{sub i} is less than 150 A/cm{sup 2}. After 7 shots, the anode surface is inspected and found to be covered with stuck matter of metallic materials such as Zn, Al, Fe, Cu. These materials seem to be produced by the ablation of the MID electrode. By eliminating the stuck matter from the surface, J{sub i} is recovered to the initial value. The decrease in J{sub i} is due to the fact that the anode is covered with the stuck matter, which prevents the growth of anode plasma. (author). 6 figs., 8 refs.

  16. Kinematic and kinetic analysis of overhand, sidearm and underhand lacrosse shot techniques.

    Science.gov (United States)

    Macaulay, Charles A J; Katz, Larry; Stergiou, Pro; Stefanyshyn, Darren; Tomaghelli, Luciano

    2017-12-01

    Lacrosse requires the coordinated performance of many complex skills. One of these skills is shooting on the opponents' net using one of three techniques: overhand, sidearm or underhand. The purpose of this study was to (i) determine which technique generated the highest ball velocity and greatest shot accuracy and (ii) identify kinematic and kinetic variables that contribute to a high velocity and high accuracy shot. Twelve elite male lacrosse players participated in this study. Kinematic data were sampled at 250 Hz, while two-dimensional force plates collected ground reaction force data (1000 Hz). Statistical analysis showed significantly greater ball velocity for the sidearm technique than overhand (P  0.05). Kinematic and kinetic variables were not significantly correlated to shot accuracy or velocity across all shot types; however, when analysed independently, the lead foot horizontal impulse showed a negative correlation with underhand ball velocity (P = 0.042). This study identifies the technique with the highest ball velocity, defines kinematic and kinetic predictors related to ball velocity and provides information to coaches and athletes concerned with improving lacrosse shot performance.

  17. Effect of Shot Peening on Tribological Behaviors of Molybdenum-Thermal Spray Coating using HVOF Method

    Directory of Open Access Journals (Sweden)

    H. Mohassel

    2017-03-01

    Full Text Available We have investigated the influence of post-shot peening on Mo-coating as compared to substrate steel 16MnCr5 (according to ZFN-413 A. Shot peening of carburized steel discs with and without Mo-coating was performed by using Shot size S230, Almen intensity 0.42 mm ’A’ and exposure time 96 sec. Tribological properties were analyzed, using pin-on-disc tribometer apparatus, under dry sliding conditions at different specific applied loads, sliding velocities and distance. Typical standardized methods were used for studying of surface integrity parameters (micro-hardness, topography and surface roughness. Surface morphology of the Mo-coating specimens with and without Shot Peening before and after wear was evaluated by Scanning Electron Microscopy. The results showed that shot peening after Mo-coating has considerable effect on improving wear resistance and because of having low friction coefficient has showed better wear behavior and tribologi cal properties over that of the un-peened Mo-coating.

  18. Feasibility of ultrasonic and eddy current methods for measurement of residual stress in shot peened metals

    International Nuclear Information System (INIS)

    Lavrentyev, Anton I.; Stucky, Paul A.; Veronesi, William A.

    2000-01-01

    Shot peening is a well-known method for extending the fatigue life of metal components by introducing compressive residual stresses near their surfaces. The capability to nondestructively evaluate the near surface residual stress would greatly aid the assurance of proper fatigue life in shot-peened components. This paper presents preliminary results from a feasibility study examining the use of ultrasonic and eddy current NDE methods for residual stress measurement in components where the stress has been introduced by shot peening. With an ultrasonic method, a variation of ultrasonic surface wave speed with shot peening intensity was measured. Near surface conductivity was measured by eddy current methods. Since the effective penetration depth of both methods employed is inversely related to the excitation frequency, by making measurements at different frequencies, each method has the potential to provide the stress-depth profile. Experiments were conducted on aluminum specimens (alloy 7075-T7351) peened within the Almen peening intensity range of 4C to 16C. The experimental results obtained demonstrate a correlation between peening intensity and Rayleigh wave velocity and between peening intensity and conductivity. The data suggests either of the methods may be suitable, with limitations, for detecting unsatisfactory levels of shot peening. Several factors were found to contribute to the measured responses: surface roughness, near surface plastic deformation (cold work) and residual stress. The contribution of each factor was studied experimentally. The feasibility of residual stress determination from the measured data is discussed

  19. A Shot Number Based Approach to Performance Analysis in Table Tennis

    Directory of Open Access Journals (Sweden)

    Tamaki Sho

    2017-01-01

    Full Text Available The current study proposes a novel approach that improves the conventional performance analysis in table tennis by introducing the concept of frequency, or the number of shots, of each shot number. The improvements over the conventional method are as follows: better accuracy of the evaluation of skills and tactics of players, additional insights into scoring and returning skills and ease of understanding the results with a single criterion. The performance analysis of matches played at the 2012 Summer Olympics in London was conducted using the proposed method. The results showed some effects of the shot number and gender differences in table tennis. Furthermore, comparisons were made between Chinese players and players from other countries, what threw light on the skills and tactics of the Chinese players. The present findings demonstrate that the proposed method provides useful information and has some advantages over the conventional method.

  20. Shot-Peening Effect on High Cycling Fatigue of Al-Cu Alloy

    Science.gov (United States)

    Fouad, Yasser; Metwally, Mostafa El

    2013-12-01

    The present work was aimed at evaluating the effects of shot-peening on the high cycle fatigue performance of the age-hardening aircraft alloy Al 2024 at different almen intensities. Shot-peening to full coverage (100 pct) was performed using spherically conditioned cut wire (SCCW 14) with an average shot size of 0.36 mm and at almen intensities of 0.1, 0.2, and 0.3 mmA. After applying the various mechanical surface treatments, the changes in the surface and near-surface layer properties such as microhardness, residual stress-depth profiles, and surface roughness were determined. The microhardness, surface roughness, and the residual stresses increased proportionally with the almen intensity. Electropolitically polished conditions were used as reference in the mechanically surface treated specimens. A significant improvement was seen in the fatigue performance of the 0.1 mmA.

  1. Clarifying beliefs underlying hunter intentions to support a ban on lead shot

    Science.gov (United States)

    Schroeder, Susan A.; Fulton, David C.; Doncarlos, Kathy

    2016-01-01

    Shot from hunting adds toxic lead to environments worldwide. Existing lead shot regulations have been instituted with little understanding of hunter beliefs and attitudes. This study applied the Theory of Reasoned Action, using a multilevel, multivariate approach, to clarify how positive and negative beliefs relate to attitudes about a ban on lead shot. Structure coefficients and commonality analysis were employed to further examine relationships between beliefs and attitudes. Results suggest that while both positive and negative outcomes influence attitudes, positive outcomes were more influential for supporters and negative beliefs for opposers. Management may need to focus on the results from hunters who indicated that they would be unlikely to support a ban, as these hunters include those who may actively oppose additional efforts to regulate lead.

  2. High-Fidelity Single-Shot Toffoli Gate via Quantum Control.

    Science.gov (United States)

    Zahedinejad, Ehsan; Ghosh, Joydip; Sanders, Barry C

    2015-05-22

    A single-shot Toffoli, or controlled-controlled-not, gate is desirable for classical and quantum information processing. The Toffoli gate alone is universal for reversible computing and, accompanied by the Hadamard gate, forms a universal gate set for quantum computing. The Toffoli gate is also a key ingredient for (nontopological) quantum error correction. Currently Toffoli gates are achieved by decomposing into sequentially implemented single- and two-qubit gates, which require much longer times and yields lower overall fidelities compared to a single-shot implementation. We develop a quantum-control procedure to construct a single-shot Toffoli gate for three nearest-neighbor-coupled superconducting transmon systems such that the fidelity is 99.9% and is as fast as an entangling two-qubit gate under the same realistic conditions. The gate is achieved by a nongreedy quantum control procedure using our enhanced version of the differential evolution algorithm.

  3. High frequency measurements of shot noise suppression in atomic-scale metal contacts

    Science.gov (United States)

    Wheeler, Patrick J.; Evans, Kenneth; Russom, Jeffrey; King, Nicholas; Natelson, Douglas

    2009-03-01

    Shot noise provides a means of assessing the number and transmission coefficients of transmitting channels in atomic- and molecular-scale junctions. Previous experiments at low temperatures in metal and semiconductor point contacts have demonstrated the expected suppression of shot noise when junction conductance is near an integer multiple of the conductance quantum, G0≡2e^2/h. Using high frequency techniques, we demonstrate the high speed acquisition of such data at room temperature in mechanical break junctions. In clean Au contacts conductance histograms with clear peaks at G0, 2G0, and 3G0 are acquired within hours, and histograms of simultaneous measurements of the shot noise show clear suppression at those conductance values. We describe the dependence of the noise on bias voltage and analyze the noise vs. conductance histograms in terms of a model that averages over transmission coefficients.

  4. Duopoly Market Analysis within One-Shot Decision Framework with Asymmetric Possibilistic Information

    Directory of Open Access Journals (Sweden)

    Peijun Guo

    2010-12-01

    Full Text Available In this paper, a newly emerging duopoly market with a short life cycle is analyzed. The partially known information of market is characterized by the possibility distribution of the parameter in the demand function. Since the life cycle of the new product is short, how many products should be produced by two rival firms is a typical one-shot decision problem. Within the one-shot decision framework, the possibilistic Cournot equilibrium is obtained for the optimal production level of each firm in a duopoly market with asymmetrical possibilistic information. The analysis results show that the proposed approaches are reasonable for one-shot decision problems, which are extensively encountered in business and economics.

  5. Shot noise of charge current in a quantum dot responded by rotating and oscillating magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Hong-Kang, E-mail: zhaohonk@yahoo.com; Zou, Wei-Ke [School of Physics, Beijing Institute of Technology, Beijing 100081 (China); Chen, Qiao [Department of Maths and Physics, Hunan Institute of Engineering, Xiangtan 411104 (China)

    2014-09-07

    We have investigated the shot noise and Fano factor of the dynamic spin-polarized quantum dot under the perturbations of a rotating magnetic field (RMF), and an oscillating magnetic field (OMF) by employing the non-equilibrium Green's function approach. The shot noise is enhanced from sub-Poissonian to super-Poissonian due to the application of RMF and OMF, and it is controlled sensitively by the tilt angle θ of RMF. The magnitude of shot noise increases as the photon energy ℏω of OMF increases, and its valley eventually is reversed to peaks as the photon energy is large enough. Double-peak structure of Fano factor is exhibited as the frequency of OMF increases to cover a large regime. The Zeeman energy μ{sub 0}B{sub 0} acts as an effective gate bias to exhibit resonant behavior, and novel peak emerges associated with the applied OMF.

  6. Sensitivity of Rooftop PV Projections in the SunShot Vision Study to Market Assumptions

    Energy Technology Data Exchange (ETDEWEB)

    Drury, E.; Denholm, P.; Margolis, R.

    2013-01-01

    The SunShot Vision Study explored the potential growth of solar markets if solar prices decreased by about 75% from 2010 to 2020. The SolarDS model was used to simulate rooftop PV demand for this study, based on several PV market assumptions--future electricity rates, customer access to financing, and others--in addition to the SunShot PV price projections. This paper finds that modeled PV demand is highly sensitive to several non-price market assumptions, particularly PV financing parameters.

  7. Shot Noise Suppression in a Quantum Point Contact with Short Channel Length

    International Nuclear Information System (INIS)

    Jeong, Heejun

    2015-01-01

    An experimental study on the current shot noise of a quantum point contact with short channel length is reported. The experimentally measured maximum energy level spacing between the ground and the first excited state of the device reached up to 7.5 meV, probably due to the hard wall confinement by using shallow electron gas and sharp point contact geometry. The two-dimensional non-equilibrium shot noise contour map shows noise suppression characteristics in a wide range of bias voltage. Fano factor analysis indicates spin-polarized transport through a short quantum point contact. (paper)

  8. Microstructural characterisation of metallic shot peened and laser shock peened Ti–6Al–4V

    International Nuclear Information System (INIS)

    Lainé, Steven J.; Knowles, Kevin M.; Doorbar, Phillip J.; Cutts, Richard D.; Rugg, David

    2017-01-01

    A detailed analysis has been conducted of Ti–6Al–4V processed by metallic shot peening and laser shock peening. Analysis by incremental hole drilling, electron backscattered diffraction microscopy, transmission electron microscopy and transmission Kikuchi diffraction microscopy is evaluated and discussed. The results of this analysis highlight the very different dislocation structures in surfaces processed by these two techniques. Transmission Kikuchi diffraction also has been used to evaluate sub-grains generated by laser shock peening. A notable feature of material processed by laser shock peening is the almost complete absence of deformation twinning, contrasting with the frequent observation of extensive deformation twinning observed in the material processed by metallic shot peening.

  9. Zero-Shot Style Transfer in Text Using Recurrent Neural Networks

    OpenAIRE

    Carlson, Keith; Riddell, Allen; Rockmore, Daniel

    2017-01-01

    Zero-shot translation is the task of translating between a language pair where no aligned data for the pair is provided during training. In this work we employ a model that creates paraphrases which are written in the style of another existing text. Since we provide the model with no paired examples from the source style to the target style during training, we call this task zero-shot style transfer. Herein, we identify a high-quality source of aligned, stylistically distinct text in Bible ve...

  10. Electromyographic Patterns during Golf Swing: Activation Sequence Profiling and Prediction of Shot Effectiveness.

    Science.gov (United States)

    Verikas, Antanas; Vaiciukynas, Evaldas; Gelzinis, Adas; Parker, James; Olsson, M Charlotte

    2016-04-23

    This study analyzes muscle activity, recorded in an eight-channel electromyographic (EMG) signal stream, during the golf swing using a 7-iron club and exploits information extracted from EMG dynamics to predict the success of the resulting shot. Muscles of the arm and shoulder on both the left and right sides, namely flexor carpi radialis, extensor digitorum communis, rhomboideus and trapezius, are considered for 15 golf players (∼5 shots each). The method using Gaussian filtering is outlined for EMG onset time estimation in each channel and activation sequence profiling. Shots of each player revealed a persistent pattern of muscle activation. Profiles were plotted and insights with respect to player effectiveness were provided. Inspection of EMG dynamics revealed a pair of highest peaks in each channel as the hallmark of golf swing, and a custom application of peak detection for automatic extraction of swing segment was introduced. Various EMG features, encompassing 22 feature sets, were constructed. Feature sets were used individually and also in decision-level fusion for the prediction of shot effectiveness. The prediction of the target attribute, such as club head speed or ball carry distance, was investigated using random forest as the learner in detection and regression tasks. Detection evaluates the personal effectiveness of a shot with respect to the player-specific average, whereas regression estimates the value of target attribute, using EMG features as predictors. Fusion after decision optimization provided the best results: the equal error rate in detection was 24.3% for the speed and 31.7% for the distance; the mean absolute percentage error in regression was 3.2% for the speed and 6.4% for the distance. Proposed EMG feature sets were found to be useful, especially when used in combination. Rankings of feature sets indicated statistics for muscle activity in both the left and right body sides, correlation-based analysis of EMG dynamics and features

  11. Different intensities of basketball drills affect jump shot accuracy of expert and junior players

    Directory of Open Access Journals (Sweden)

    Giuseppe Marcolin

    2018-02-01

    Full Text Available Background In basketball a maximum accuracy at every game intensity is required while shooting. The aim of the present study was to investigate the acute effect of three different drill intensity simulation protocols on jump shot accuracy in expert and junior basketball players. Materials & Methods Eleven expert players (age 26 ± 6 yrs, weight 86 ± 11 kg, height 192 ± 8 cm and ten junior players (age 18 ± 1 yrs, weight 75 ± 12 kg, height 184 ± 9 cm completed three series of twenty jump shots at three different levels of exertion. Counter Movement Jump (CMJ height was also measured after each series of jump shots. Exertion’s intensity was induced manipulating the basketball drills. Heart rate was measured for the whole duration of the tests while the rating of perceived exertion (RPE was collected at the end of each series of shots. Results Heart rate and rating of perceived exertion (RPE were statistically different in the three conditions for both expert and junior players. CMJ height remained almost unchanged in both groups. Jump shot accuracy decreased with increasing drills intensity both in experts and junior players. Expert players showed higher accuracy than junior players for all the three levels of exertion (83% vs 64%, p < 0.001; 75% vs 57%, p < 0.05; 76% vs 60%, p < 0.01. Moreover, for the most demanding level of exertion, experts showed a higher accuracy in the last ten shots compared to the first ten shots (82% vs 70%, p < 0.05. Discussion Experts coped better with the different exertion’s intensities, thus maintaining a higher level of performance. The introduction of technical short bouts of high-intensity sport-specific exercises into skill sessions should be proposed to improve jump shot accuracy during matches.

  12. Single-Shot Spectrometry for X-Ray Free-Electron Lasers

    International Nuclear Information System (INIS)

    Yabashi, Makina; Ishikawa, Tetsuya; Hastings, Jerome B.; Zolotorev, Max S.; Mimura, Hidekazu; Yumoto, Hirokatsu; Matsuyama, Satoshi; Yamauchi, Kazuto

    2006-01-01

    An experimental scheme to realize single-shot spectrometry for the diagnostics of x-ray free-electron lasers (XFELs) is presented. The combination of an ultraprecisely figured mirror and a perfect crystal form a simple, high-precision spectrometer that can cover an energy range from a few eV to a hundred eV with high resolution. The application of the spectrometer to determine XFEL pulse widths was investigated theoretically and experimentally. It has been shown that the present system can determine pulse widths from sub-fs to ps in a single shot even for spontaneous radiation. The system can be easily extended to even shorter pulses

  13. Shot noise enhancement from non-equilibrium plasmons in Luttinger liquid junctions

    International Nuclear Information System (INIS)

    Kim, Jaeuk U; Kinaret, Jari M; Choi, Mahn-Soo

    2005-01-01

    We consider a quantum wire double junction system with each wire segment described by a spinless Luttinger model, and study theoretically shot noise in this system in the sequential tunnelling regime. We find that the non-equilibrium plasmonic excitations in the central wire segment give rise to qualitatively different behaviour compared to the case with equilibrium plasmons. In particular, shot noise is greatly enhanced by them, and exceeds the Poisson limit. We show that the enhancement can be explained by the emergence of several current-carrying processes, and that the effect disappears if the channels effectively collapse to one because of fast plasmon relaxation processes, for example

  14. Electromyographic Patterns during Golf Swing: Activation Sequence Profiling and Prediction of Shot Effectiveness

    Directory of Open Access Journals (Sweden)

    Antanas Verikas

    2016-04-01

    Full Text Available This study analyzes muscle activity, recorded in an eight-channel electromyographic (EMG signal stream, during the golf swing using a 7-iron club and exploits information extracted from EMG dynamics to predict the success of the resulting shot. Muscles of the arm and shoulder on both the left and right sides, namely flexor carpi radialis, extensor digitorum communis, rhomboideus and trapezius, are considered for 15 golf players (∼5 shots each. The method using Gaussian filtering is outlined for EMG onset time estimation in each channel and activation sequence profiling. Shots of each player revealed a persistent pattern of muscle activation. Profiles were plotted and insights with respect to player effectiveness were provided. Inspection of EMG dynamics revealed a pair of highest peaks in each channel as the hallmark of golf swing, and a custom application of peak detection for automatic extraction of swing segment was introduced. Various EMG features, encompassing 22 feature sets, were constructed. Feature sets were used individually and also in decision-level fusion for the prediction of shot effectiveness. The prediction of the target attribute, such as club head speed or ball carry distance, was investigated using random forest as the learner in detection and regression tasks. Detection evaluates the personal effectiveness of a shot with respect to the player-specific average, whereas regression estimates the value of target attribute, using EMG features as predictors. Fusion after decision optimization provided the best results: the equal error rate in detection was 24.3% for the speed and 31.7% for the distance; the mean absolute percentage error in regression was 3.2% for the speed and 6.4% for the distance. Proposed EMG feature sets were found to be useful, especially when used in combination. Rankings of feature sets indicated statistics for muscle activity in both the left and right body sides, correlation-based analysis of EMG

  15. Single-shot self-interference incoherent digital holography using off-axis configuration.

    Science.gov (United States)

    Hong, Jisoo; Kim, Myung K

    2013-12-01

    We propose a single-shot incoherent holographic imaging technique that adopts self-interference incoherent digital holography (SIDH) with slight tilt of the plane mirror in the optical configuration. The limited temporal coherence length of the illumination leads the guide-star hologram of the proposed system to have a Gaussian envelope of elliptical ring shape. The observation shows that the reconstruction by cross correlation with the guide-star hologram achieves better quality than the usual propagation methods. Experimentally, we verify that the hologram and 3D reconstruction can be implemented incoherently with the proposed single-shot off-axis SIDH.

  16. Laser Shot Peening System Final Report CRADA No. TC-1369-96

    Energy Technology Data Exchange (ETDEWEB)

    Stuart, B. C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Harris, F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-09-27

    This CRADA project was established with a primary goal to develop a laser shot peening system which could operate at production throughput rates and produce the desired depth and intensity of induced shots. The first objective was to understand all parameters required for acceptable peening, including pulse energy, pulse temporal format, pulse spatial format, sample configuration and tamping mechanism. The next objective was to demonstrate the technique on representative samples and then on representative parts. The final objective was to implement the technology into a meaningful industrial peen.

  17. Shot-peening effect on the structure, microhardness, and compressive stresses of the austenitic steel 1.4539

    Directory of Open Access Journals (Sweden)

    Barbara Nasiłowska

    2015-06-01

    Full Text Available This article presents shot-peening effect on the structure, microhardness, and compressive stresses of the austenitic steel 1.4539. The research shows strengthening of the top layer and the formation of compressive stresses in the subsurface layers of the shot-peening elements.[b]Keyword[/b]: austenitic steel 1.4539, residual stresses, Waisman-Phillips’a method

  18. Biomechanical Comparison of Three Perceived Effort Set Shots in Team Handball Players.

    Science.gov (United States)

    Plummer, Hillary A; Gascon, Sarah S; Oliver, Gretchen D

    2017-01-01

    Plummer, HA, Gascon, SS, and Oliver, GD. Biomechanical comparison of three perceived effort set shots in team handball players. J Strength Cond Res 31(1): 80-87, 2017-Shoulder injuries are prevalent in the sport of team handball; however, no guidelines currently exist in the implementation of an interval throwing protocol for players returning from an upper extremity injury. These guidelines exist for the sport of baseball, but team handball may present additional challenges due to greater ball mass that must be accounted for. The purpose of this study was to examine kinematic differences in the team handball set shot at 50, 75, and 100% effort which are common throwing intensities in throwing protocols. Eleven male team handball players (23.09 ± 3.05 years; 185.12 ± 8.33 cm; 89.65 ± 12.17 kg) volunteered. An electromagnetic tracking system was used to collect kinematic data at the pelvis, trunk, scapula, and shoulder. Kinematic differences at the shoulder, trunk, and pelvis were observed across effort levels throughout the set shot with most occurring at ball release and maximum internal rotation. Significant differences in ball speed were observed between all 3 effort level shots (p handball players are able to gauge the effort at which they shoot; however, it cannot be assumed that these speeds will be at a certain percentage of their maximum. The results of this study provide valuable evidence that can be used to prepare a team handball player to return to throwing activities.

  19. Neural Computations Mediating One-Shot Learning in the Human Brain

    Science.gov (United States)

    Lee, Sang Wan; O’Doherty, John P.; Shimojo, Shinsuke

    2015-01-01

    Incremental learning, in which new knowledge is acquired gradually through trial and error, can be distinguished from one-shot learning, in which the brain learns rapidly from only a single pairing of a stimulus and a consequence. Very little is known about how the brain transitions between these two fundamentally different forms of learning. Here we test a computational hypothesis that uncertainty about the causal relationship between a stimulus and an outcome induces rapid changes in the rate of learning, which in turn mediates the transition between incremental and one-shot learning. By using a novel behavioral task in combination with functional magnetic resonance imaging (fMRI) data from human volunteers, we found evidence implicating the ventrolateral prefrontal cortex and hippocampus in this process. The hippocampus was selectively “switched” on when one-shot learning was predicted to occur, while the ventrolateral prefrontal cortex was found to encode uncertainty about the causal association, exhibiting increased coupling with the hippocampus for high-learning rates, suggesting this region may act as a “switch,” turning on and off one-shot learning as required. PMID:25919291

  20. A practical globalization of one-shot optimization for optimal design of tokamak divertors

    Energy Technology Data Exchange (ETDEWEB)

    Blommaert, Maarten, E-mail: maarten.blommaert@kuleuven.be [Institute of Energy and Climate Research (IEK-4), FZ Jülich GmbH, D-52425 Jülich (Germany); Dekeyser, Wouter; Baelmans, Martine [KU Leuven, Department of Mechanical Engineering, 3001 Leuven (Belgium); Gauger, Nicolas R. [TU Kaiserslautern, Chair for Scientific Computing, 67663 Kaiserslautern (Germany); Reiter, Detlev [Institute of Energy and Climate Research (IEK-4), FZ Jülich GmbH, D-52425 Jülich (Germany)

    2017-01-01

    In past studies, nested optimization methods were successfully applied to design of the magnetic divertor configuration in nuclear fusion reactors. In this paper, so-called one-shot optimization methods are pursued. Due to convergence issues, a globalization strategy for the one-shot solver is sought. Whereas Griewank introduced a globalization strategy using a doubly augmented Lagrangian function that includes primal and adjoint residuals, its practical usability is limited by the necessity of second order derivatives and expensive line search iterations. In this paper, a practical alternative is offered that avoids these drawbacks by using a regular augmented Lagrangian merit function that penalizes only state residuals. Additionally, robust rank-two Hessian estimation is achieved by adaptation of Powell's damped BFGS update rule. The application of the novel one-shot approach to magnetic divertor design is considered in detail. For this purpose, the approach is adapted to be complementary with practical in parts adjoint sensitivities. Using the globalization strategy, stable convergence of the one-shot approach is achieved.

  1. IMPROVED MOTOR-TIMING: EFFECTS OF SYNCHRONIZED METRO-NOME TRAINING ON GOLF SHOT ACCURACY

    Directory of Open Access Journals (Sweden)

    Louise Rönnqvist

    2009-12-01

    Full Text Available This study investigates the effect of synchronized metronome training (SMT on motor timing and how this training might affect golf shot accuracy. Twenty-six experienced male golfers participated (mean age 27 years; mean golf handicap 12.6 in this study. Pre- and post-test investigations of golf shots made by three different clubs were conducted by use of a golf simulator. The golfers were randomized into two groups: a SMT group and a Control group. After the pre-test, the golfers in the SMT group completed a 4-week SMT program designed to improve their motor timing, the golfers in the Control group were merely training their golf-swings during the same time period. No differences between the two groups were found from the pre-test outcomes, either for motor timing scores or for golf shot accuracy. However, the post-test results after the 4-weeks SMT showed evident motor timing improvements. Additionally, significant improvements for golf shot accuracy were found for the SMT group and with less variability in their performance. No such improvements were found for the golfers in the Control group. As with previous studies that used a SMT program, this study's results provide further evidence that motor timing can be improved by SMT and that such timing improvement also improves golf accuracy

  2. Comparative study of deep learning methods for one-shot image classification (abstract)

    NARCIS (Netherlands)

    van den Bogaert, J.; Mohseni, H.; Khodier, M.; Stoyanov, Y.; Mocanu, D.C.; Menkovski, V.

    2017-01-01

    Training deep learning models for images classification requires large amount of labeled data to overcome the challenges of overfitting and underfitting. Usually, in many practical applications, these labeled data are not available. In an attempt to solve this problem, the one-shot learning paradigm

  3. Watching More Closely: Shot Scale Affects Film Viewers’ Theory of Mind Tendency But Not Ability

    Science.gov (United States)

    Rooney, Brendan; Bálint, Katalin E.

    2018-01-01

    Recent research debates the effects of exposure to narrative fiction on recognition of mental states in others and self, referred to as Theory of Mind. The current study explores the mechanisms by which such effects could occur in fictional film. Using manipulated film scenes, we conducted a between subject experiment (N = 136) exploring how film shot-scale affects viewers’ Theory of Mind. Specifically, in our methods we distinguish between the trait Theory of Mind abilities (ToM ability), and the state-like tendency to recognize mental states in others and self (ToM tendency). Results showed that close-up shots (compared to long shots) of a character was associated with higher levels of Theory of Mind tendency, when the facial expression was sad but not when it was neutral. And this effect did not transfer to other characters in the film. There was also no observable effect of character depiction on viewers’ general Theory of Mind ability. Together the findings suggest that formal and content features of shot scale can elicit Theory of Mind responses by directing attention toward character mental states rather than improving viewers’ general Theory of Mind ability. PMID:29387032

  4. Shot noise as a probe of spin-polarized transport through single atoms

    DEFF Research Database (Denmark)

    Burtzlaff, Andreas; Weismann, Alexander; Brandbyge, Mads

    2015-01-01

    Single atoms on Au(111) surfaces have been contacted with the Au tip of a low temperature scanning tunneling microscope. The shot noise of the current through these contacts has been measured up to frequencies of 120 kHz and Fano factors have been determined to characterize the transport channels...

  5. Light emission probing quantum shot noise and charge fluctuations at a biased molecular junction

    DEFF Research Database (Denmark)

    Schneider, N.L.; Lu, Jing Tao; Brandbyge, M.

    2012-01-01

    The emission of plasmonic light from a single C60 molecule on Cu(111) is probed in a scanning tunneling microscope from the weak-coupling, tunneling range to strong coupling of the molecule to the electrodes at contact. At positive sample voltage the photon yield decreases owing to shot...

  6. Shot-noise-weighted processes : a new family of spatial point processes

    NARCIS (Netherlands)

    M.N.M. van Lieshout (Marie-Colette); I.S. Molchanov (Ilya)

    1995-01-01

    textabstractThe paper suggests a new family of of spatial point processes distributions. They are defined by means of densities with respect to the Poisson point process within a bounded set. These densities are given in terms of a functional of the shot-noise process with a given influence

  7. Feature Selection Methods for Zero-Shot Learning of Neural Activity

    Directory of Open Access Journals (Sweden)

    Carlos A. Caceres

    2017-06-01

    Full Text Available Dimensionality poses a serious challenge when making predictions from human neuroimaging data. Across imaging modalities, large pools of potential neural features (e.g., responses from particular voxels, electrodes, and temporal windows have to be related to typically limited sets of stimuli and samples. In recent years, zero-shot prediction models have been introduced for mapping between neural signals and semantic attributes, which allows for classification of stimulus classes not explicitly included in the training set. While choices about feature selection can have a substantial impact when closed-set accuracy, open-set robustness, and runtime are competing design objectives, no systematic study of feature selection for these models has been reported. Instead, a relatively straightforward feature stability approach has been adopted and successfully applied across models and imaging modalities. To characterize the tradeoffs in feature selection for zero-shot learning, we compared correlation-based stability to several other feature selection techniques on comparable data sets from two distinct imaging modalities: functional Magnetic Resonance Imaging and Electrocorticography. While most of the feature selection methods resulted in similar zero-shot prediction accuracies and spatial/spectral patterns of selected features, there was one exception; A novel feature/attribute correlation approach was able to achieve those accuracies with far fewer features, suggesting the potential for simpler prediction models that yield high zero-shot classification accuracy.

  8. Single-shot LIBS spectral quality for waste particles in open air

    NARCIS (Netherlands)

    Xia, H.; Bakker, M.C.M.

    2015-01-01

    This work investigates the ability of LIBS to produce quality spectra from small particles of concrete demolition waste using single-shot spectra collected in open air. The 2–8?mm materials are rounded river gravel, green glass shards, and plastic flakes. Considered are focal length, air, moisture,

  9. The effect of shot biopsy on behavior, salivary cortisol, and heart rate in slaughter pigs

    NARCIS (Netherlands)

    Geverink, NA; Ruis, MAW; Eisen, R; Lambooij, E; Blokhuis, HJ; Wiegant, VM

    This paper describes behavioral and. physiological responses of pigs to shot biopsy, an experimental method used to study muscle tissue processes or to:predict meat quality. One biopsy sample from the longissimus muscle was obtained from 23-wk-old gilts (n = 10) using a cannula connected to a

  10. Laser Shot Peening Final Report CRADA No. TC-02059-03

    Energy Technology Data Exchange (ETDEWEB)

    Stuart, B. C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hackel, L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-09-27

    This was a collaborative effort between The Regents of the University of California, Lawrence Livermore National Laboratory (LLNL) and Metal Improvement Company, Inc. (MIC), to further develop the laser shot peening technology. This project had an emphasis on laser development and government and military applications including DOE’s natural gas and oil technology program (NGOTP), Yucca Mountain Project (YMP), F-22 Fighter, etc.

  11. Shot-noise dominant regime of a nanoparticle in a laser beam

    Science.gov (United States)

    Zhong, Changchun; Robicheaux, Francis

    2017-04-01

    The technique of laser levitation of nanoparticles has become increasingly promising in the study of cooling and controlling mesoscopic quantum systems. Unlike a mechanical system, the levitated nanoparticle is less exposed to thermalization and decoherence due to the absence of direct contact with a thermal environment. In ultrahigh vacuum, the dominant source of decoherence comes from the unavoidable photon recoil from the optical trap which sets an ultimate bound for the control of levitated systems. In this paper, we study the shot noise heating and the parametric feedback cooling of an optically trapped anisotropic nanoparticle in the laser shot noise dominant regime. The rotational trapping frequency and shot noise heating rate have a dependence on the shape of the trapped particle. For an ellipsoidal particle, the ratio of the axis lengths and the overall size controls the shot noise heating rate relative to the rotational frequency. For a near spherical nanoparticle, the effective heating rate for the rotational degrees of freedom is smaller than that for translation suggesting that the librational ground state may be easier to achieve than the vibrational ground state.

  12. Analysis of shots on target and goals scored in soccer matches ...

    African Journals Online (AJOL)

    The aim of this study was to analyse the characteristics and patterns of shots on target and goals scored during the 2012-European Championship. The broadcasted matches were recorded and converted into electronic video files for a computerbased analysis. This quantitative study examined 31 matches of the ...

  13. Two-step estimation procedures for inhomogeneous shot-noise Cox processes

    DEFF Research Database (Denmark)

    Prokesová, Michaela; Dvorák, Jirí; Jensen, Eva B. Vedel

    In the present paper we develop several two-step estimation procedures for inhomogeneous shot-noise Cox processes. The intensity function is parametrized by the inhomogeneity parameters while the pair-correlation function is parametrized by the interaction parameters. The suggested procedures...

  14. Effect of Shot Peening on the Fatigue Strength of Automotive Tubular Stabilizer Bars DC 218

    Directory of Open Access Journals (Sweden)

    Wittek A.M.

    2016-12-01

    Full Text Available This paper concerns issues related to the development of designs of stabilizer bars for new motor vehicle models. It involves not only the designing of a stabilizer bar with the shape required by the manufacturer, but also the preparation of bending and heat treatment processes as well as the performance of strength and fatigue tests. In the prototype development phase, the simulations techniques (FEM may be used to assess the design. The article contains a detailed analysis of a stabilizer bar designated with the DC 218 VA symbol. Performed numerical strength and fatigue calculations showed that the developed stabilizer bar design with the desired shape did not achieve the required number of fatigue cycles. It was also proven at the test stand by testing a prototype stabilizer bar. Therefore, it was suggested to supplement the technological process with an additional shot peening operation whose main aim was to reduce the length of microcracks on the stabilizer bar’s surface. This effect was confirmed during comparative metallographic tests of not shot – peened and shot – peened stabilizer bars. After shot peening, the analysed stabilizer bar reached a fatigue strength which exceeded the limits set by the manufacturer.

  15. A solid target for SINQ based on a Pb-shot Pebble-bed

    International Nuclear Information System (INIS)

    Atchison, F.; Heidenreich, G.

    1991-01-01

    Preliminary results from scoping calculations examining the possibilities of implementing a Pebble-bed of Pb-shot as a target for SINQ are presented. The primary design objects are set out and estimates of heating and activation given. Cooling circuit parameters are discussed and estimates for operating conditions presented. A short discussion of problems associated with a realisation is included. (author)

  16. Shot noise limit of the optical 3D measurement methods for smooth surfaces

    Czech Academy of Sciences Publication Activity Database

    Pavlíček, Pavel; Pech, Miroslav

    2016-01-01

    Roč. 27, č. 3 (2016), 1-7, č. článku 035205. ISSN 0957-0233 R&D Projects: GA ČR GA13-12301S Institutional support: RVO:68378271 Keywords : measurement uncertainty * shot noise * 3D measurement * interferometry Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.585, year: 2016

  17. 76 FR 58108 - Safety Zone; Ryder Cup Captain's Duel Golf Shot, Chicago River, Chicago, IL

    Science.gov (United States)

    2011-09-20

    ...-AA00 Safety Zone; Ryder Cup Captain's Duel Golf Shot, Chicago River, Chicago, IL AGENCY: Coast Guard... the Chicago River during a golfing event that will involve hitting golf balls from land onto a... vessels from the hazards associated with golf balls being hit from land onto a stationary barge in the...

  18. Estimation of post disruption plasma temperature for fast current quench Aditya plasma shots

    International Nuclear Information System (INIS)

    Purohit, S.; Chowdhuri, M.B.; Joisa, Y.S.; Raval, J.V.; Ghosh, J.; Jha, R.

    2013-01-01

    Characteristics of tokamak current quenches are an important issue for the determination of electromagnetic forces that act on the in-vessel components and vacuum vessel during major disruptions. It is observed that thermal quench is followed by a sharp current decay. Fast current quench disruptive plasma shots were investigated for ADITYA tokamak. The current decay time was determined for the selected shots, which were in the range of 0.8 msec to 2.5 msec. This current decay information was then applied to L/R model, frequently employed for the estimation of the current decay time in tokamak plasmas, considering plasma inductance and plasma resistivity. This methodology was adopted for the estimation of the post disruption plasma temperature using the experimentally observed current decay time for the fast current quench disruptive ADITYA plasma shots. The study reveals that for the identified shots there is a constant increase in the current decay time with the post disruption plasma temperature. The investigations also explore the behavior post disruption plasma temperature and the current decay time as a function of the edge safety factor, Q. Post disruption plasma temperature and the current decay time exhibits a decrease with the increase in the value Q. (author)

  19. Visual one-shot learning as an 'anti-camouflage device': a novel morphing paradigm.

    Science.gov (United States)

    Ishikawa, Tetsuo; Mogi, Ken

    2011-09-01

    Once people perceive what is in the hidden figure such as Dallenbach's cow and Dalmatian, they seldom seem to come back to the previous state when they were ignorant of the answer. This special type of learning process can be accomplished in a short time, with the effect of learning lasting for a long time (visual one-shot learning). Although it is an intriguing cognitive phenomenon, the lack of the control of difficulty of stimuli presented has been a problem in research. Here we propose a novel paradigm to create new hidden figures systematically by using a morphing technique. Through gradual changes from a blurred and binarized two-tone image to a blurred grayscale image of the original photograph including objects in a natural scene, spontaneous one-shot learning can occur at a certain stage of morphing when a sufficient amount of information is restored to the degraded image. A negative correlation between confidence levels and reaction times is observed, giving support to the fluency theory of one-shot learning. The correlation between confidence ratings and correct recognition rates indicates that participants had an accurate introspective ability (metacognition). The learning effect could be tested later by verifying whether or not the target object was recognized quicker in the second exposure. The present method opens a way for a systematic production of "good" hidden figures, which can be used to demystify the nature of visual one-shot learning.

  20. Single-shot spiral imaging enabled by an expanded encoding model: Demonstration in diffusion MRI.

    Science.gov (United States)

    Wilm, Bertram J; Barmet, Christoph; Gross, Simon; Kasper, Lars; Vannesjo, S Johanna; Haeberlin, Max; Dietrich, Benjamin E; Brunner, David O; Schmid, Thomas; Pruessmann, Klaas P

    2017-01-01

    The purpose of this work was to improve the quality of single-shot spiral MRI and demonstrate its application for diffusion-weighted imaging. Image formation is based on an expanded encoding model that accounts for dynamic magnetic fields up to third order in space, nonuniform static B 0 , and coil sensitivity encoding. The encoding model is determined by B 0 mapping, sensitivity mapping, and concurrent field monitoring. Reconstruction is performed by iterative inversion of the expanded signal equations. Diffusion-tensor imaging with single-shot spiral readouts is performed in a phantom and in vivo, using a clinical 3T instrument. Image quality is assessed in terms of artefact levels, image congruence, and the influence of the different encoding factors. Using the full encoding model, diffusion-weighted single-shot spiral imaging of high quality is accomplished both in vitro and in vivo. Accounting for actual field dynamics, including higher orders, is found to be critical to suppress blurring, aliasing, and distortion. Enhanced image congruence permitted data fusion and diffusion tensor analysis without coregistration. Use of an expanded signal model largely overcomes the traditional vulnerability of spiral imaging with long readouts. It renders single-shot spirals competitive with echo-planar readouts and thus deploys shorter echo times and superior readout efficiency for diffusion imaging and further prospective applications. Magn Reson Med 77:83-91, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  1. In vivo single-shot (13)C spectroscopic imaging of hyperpolarized metabolites by spatiotemporal encoding

    DEFF Research Database (Denmark)

    Schmidt, Rita; Laustsen, Christoffer; Dumez, Jean-Nicolas

    2014-01-01

    are necessary. Several approaches have been customized for hyperpolarized (13)C MRI, including CSI with a center-out k-space encoding, EPSI, and spectrally selective pulses in combination with spiral EPI acquisitions. Recent studies have described the potential of single-shot alternatives based...... temporal) data sets were obtained at 7T from a murine lymphoma tumor model....

  2. Big Kids Need Shots Too (A Minute of Health with CDC)

    Centers for Disease Control (CDC) Podcasts

    At ages 11 through 12, vaccines are recommended to protect against cancers caused by HPV, as well as to prevent tetanus, diphtheria, pertussis, and meningitis. In addition, everyone in the family should get a flu vaccine each year. This podcast discusses the importance of ensuring preteens and teens stay current on their shots.

  3. Watching More Closely: Shot Scale Affects Film Viewers’ Theory of Mind Tendency But Not Ability

    Directory of Open Access Journals (Sweden)

    Brendan Rooney

    2018-01-01

    Full Text Available Recent research debates the effects of exposure to narrative fiction on recognition of mental states in others and self, referred to as Theory of Mind. The current study explores the mechanisms by which such effects could occur in fictional film. Using manipulated film scenes, we conducted a between subject experiment (N = 136 exploring how film shot-scale affects viewers’ Theory of Mind. Specifically, in our methods we distinguish between the trait Theory of Mind abilities (ToM ability, and the state-like tendency to recognize mental states in others and self (ToM tendency. Results showed that close-up shots (compared to long shots of a character was associated with higher levels of Theory of Mind tendency, when the facial expression was sad but not when it was neutral. And this effect did not transfer to other characters in the film. There was also no observable effect of character depiction on viewers’ general Theory of Mind ability. Together the findings suggest that formal and content features of shot scale can elicit Theory of Mind responses by directing attention toward character mental states rather than improving viewers’ general Theory of Mind ability.

  4. Regularity of particle velocity decrease with scale d distance for rockbursts and shot holes

    Czech Academy of Sciences Publication Activity Database

    Holub, Karel; Rušajová, Jana

    2015-01-01

    Roč. 20, č. 2 (2015), s. 80-85 ISSN 1335-1788 Institutional support: RVO:68145535 Keywords : rockburst * hole shot * particle velocity * scaled distance * cylindrical and spherical waveforms Subject RIV: DC - Siesmology, Volcanology, Earth Structure Impact factor: 0.390, year: 2015 http://actamont.tuke.sk/pdf/2015/n2/2holub.pdf

  5. Neural computations mediating one-shot learning in the human brain.

    Directory of Open Access Journals (Sweden)

    Sang Wan Lee

    2015-04-01

    Full Text Available Incremental learning, in which new knowledge is acquired gradually through trial and error, can be distinguished from one-shot learning, in which the brain learns rapidly from only a single pairing of a stimulus and a consequence. Very little is known about how the brain transitions between these two fundamentally different forms of learning. Here we test a computational hypothesis that uncertainty about the causal relationship between a stimulus and an outcome induces rapid changes in the rate of learning, which in turn mediates the transition between incremental and one-shot learning. By using a novel behavioral task in combination with functional magnetic resonance imaging (fMRI data from human volunteers, we found evidence implicating the ventrolateral prefrontal cortex and hippocampus in this process. The hippocampus was selectively "switched" on when one-shot learning was predicted to occur, while the ventrolateral prefrontal cortex was found to encode uncertainty about the causal association, exhibiting increased coupling with the hippocampus for high-learning rates, suggesting this region may act as a "switch," turning on and off one-shot learning as required.

  6. Comparative Study on the Efficacy of Two Regimens of Single-Shot ...

    African Journals Online (AJOL)

    Objective: To assess and compare the satisfaction and efficacy of two regimens of single-shot spinal blocks for the relief of labor pain in women who present in active phase of labour. Design: A prospective randomised single-blind observational study. Setting: Labour ward of Kenyatta National Hospital, Nairobi. Subjects: All ...

  7. A study on the corrosion characteristics of gear steel by shot peening

    International Nuclear Information System (INIS)

    Kang, Jin Shik; Kim, Tae Hyung; Cheong, Seong Kyun; Yoon, Jong Ku; Lee, Seung Ho

    2001-01-01

    The surface treatment technique to increase corrosion resistance is very important in mechanical components of structures. Therefore, this paper investigates the effects of shot peening on the corrosion resistance of SCM 420steel. The results show that the surface compressive residual stress largely increases, which cause the increase of corrosion resistance

  8. Improved design and durability of aluminum die casting horizontal shot sleeves

    Science.gov (United States)

    Birceanu, Sebastian

    The design and performance of shot sleeves is critical in meeting the engineering requirements of aluminum die cast parts. Improvement in shot sleeve materials have a major impact on dimensional stability, reproducibility and quality of the product. This investigation was undertaken in order to improve the life of aluminum die casting horizontal shot sleeves. Preliminary pin tests were run to evaluate the soldering, wash-out and thermal fatigue behavior of commercially available materials and coatings. An experimental rig was designed and constructed for shot sleeve configuration evaluation. Fabrication and testing of experimental shot sleeves was based upon preliminary results and manufacturing costs. Three shot sleeve designs and materials were compared to a reference nitrided H13 sleeve. Nitrided H13 is the preferred material for aluminum die casting shot sleeves because of wear resistance, strength and relative good soldering and wash-out resistance. The study was directed towards damage evaluation on the area under the pouring hole. This area is the most susceptible to damage because of high temperatures and impingement of molten aluminum. The results of this study showed that tungsten and molybdenum had the least amount of soldering and wash-out damage, and the best thermal fatigue resistance. Low solubility in molten aluminum and stability of intermetallic layers are main factors that determine the soldering and wash-out behavior. Thermal conductivity and thermal expansion coefficient directly influence thermal fatigue behavior. TiAlN nanolayered coating was chosen as the material with the best damage resistance among several commercial PVD coatings, because of relatively large thickness and simple deposition conditions. The results show that molybdenum thermal sprayed coating provided the best protection against damage under the pouring hole. Improved bonding is however required for life extension of the coating. TiAlN PVD coating applied on H13 nitrided

  9. From single-shot towards general work extraction in a quantum thermodynamic framework

    International Nuclear Information System (INIS)

    Gemmer, Jochen; Anders, Janet

    2015-01-01

    This paper considers work extraction from a quantum system to a work storage system (or weight) following Horodecki and Oppenheim (2013 Nat. Commun. 4 2059). An alternative approach is here developed that relies on the comparison of subspace dimensions without a need to introduce thermo-majorization used previously. Optimal single shot work for processes where a weight transfers from (a) a single energy level to another single energy level is then re-derived. In addition we discuss the final state of the system after work extraction and show that the system typically ends in its thermal state, while there are cases where the system is only close to it. The work of formation in the single level transfer setting is also re-derived. The approach presented now allows the extension of the single shot work concept to work extraction (b) involving multiple final levels of the weight. A key conclusion here is that the single shot work for case (a) is appropriate only when a resonance of a particular energy is required. When wishing to identify ‘work extraction’ with finding the weight in a specific available energy or any higher energy a broadening of the single shot work concept is required. As a final contribution we consider transformations of the system that (c) result in general weight state transfers. Introducing a transfer-quantity allows us to formulate minimum requirements for transformations to be at all possible in a thermodynamic framework. We show that choosing the free energy difference of the weight as the transfer-quantity one recovers various single shot results including single level transitions (a), multiple final level transitions (b), and recent results on restricted sets of multi-level to multi-level weight transfers. (paper)

  10. Is Attribute-Based Zero-Shot Learning an Ill-Posed Strategy?

    KAUST Repository

    Alabdulmohsin, Ibrahim; Cisse, Moustapha; Zhang, Xiangliang

    2016-01-01

    One transfer learning approach that has gained a wide popularity lately is attribute-based zero-shot learning. Its goal is to learn novel classes that were never seen during the training stage. The classical route towards realizing this goal is to incorporate a prior knowledge, in the form of a semantic embedding of classes, and to learn to predict classes indirectly via their semantic attributes. Despite the amount of research devoted to this subject lately, no known algorithm has yet reported a predictive accuracy that could exceed the accuracy of supervised learning with very few training examples. For instance, the direct attribute prediction (DAP) algorithm, which forms a standard baseline for the task, is known to be as accurate as supervised learning when as few as two examples from each hidden class are used for training on some popular benchmark datasets! In this paper, we argue that this lack of significant results in the literature is not a coincidence; attribute-based zero-shot learning is fundamentally an ill-posed strategy. The key insight is the observation that the mechanical task of predicting an attribute is, in fact, quite different from the epistemological task of learning the “correct meaning” of the attribute itself. This renders attribute-based zero-shot learning fundamentally ill-posed. In more precise mathematical terms, attribute-based zero-shot learning is equivalent to the mirage goal of learning with respect to one distribution of instances, with the hope of being able to predict with respect to any arbitrary distribution. We demonstrate this overlooked fact on some synthetic and real datasets. The data and software related to this paper are available at https://mine. kaust.edu.sa/Pages/zero-shot-learning.aspx. © Springer International Publishing AG 2016.

  11. Is Attribute-Based Zero-Shot Learning an Ill-Posed Strategy?

    KAUST Repository

    Alabdulmohsin, Ibrahim

    2016-09-03

    One transfer learning approach that has gained a wide popularity lately is attribute-based zero-shot learning. Its goal is to learn novel classes that were never seen during the training stage. The classical route towards realizing this goal is to incorporate a prior knowledge, in the form of a semantic embedding of classes, and to learn to predict classes indirectly via their semantic attributes. Despite the amount of research devoted to this subject lately, no known algorithm has yet reported a predictive accuracy that could exceed the accuracy of supervised learning with very few training examples. For instance, the direct attribute prediction (DAP) algorithm, which forms a standard baseline for the task, is known to be as accurate as supervised learning when as few as two examples from each hidden class are used for training on some popular benchmark datasets! In this paper, we argue that this lack of significant results in the literature is not a coincidence; attribute-based zero-shot learning is fundamentally an ill-posed strategy. The key insight is the observation that the mechanical task of predicting an attribute is, in fact, quite different from the epistemological task of learning the “correct meaning” of the attribute itself. This renders attribute-based zero-shot learning fundamentally ill-posed. In more precise mathematical terms, attribute-based zero-shot learning is equivalent to the mirage goal of learning with respect to one distribution of instances, with the hope of being able to predict with respect to any arbitrary distribution. We demonstrate this overlooked fact on some synthetic and real datasets. The data and software related to this paper are available at https://mine. kaust.edu.sa/Pages/zero-shot-learning.aspx. © Springer International Publishing AG 2016.

  12. Evaluation of cardiac function using multi-shot echo planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, Tadashi; Tanitame, Nobuko; Hata, Ryoichiro; Hirai, Nobuhiko; Ikeda, Midori; Ono, Chiaki; Fukuoka, Haruhito; Ito, Katsuhide [Hiroshima Univ. (Japan). School of Medicine

    1998-01-01

    In this study, we performed multi-shot echo planar imaging (8 shot, TR/TE/FL=55 ms/18 ms/60 degrees) and k-space segmented fast gradient echo sequence (8 views per segment, TR/TE/FL=9.9 ms/1.8 ms/30 degrees) to assess cardiac function in healthy volunteers. Transaxial sections of the entire heart were obtained with both sequences in ECG triggered, breath hold, and with a 256 x 128 matrix. Resulting temporal resolution was 55 ms for echo planar imaging, and 71 ms for k-space segmented fast gradient echo sequence, respectively. Ventricular volume and ejection fraction of both ventricles and left ventricular mass obtained with multi-shot echo planar imaging were assessed in comparison with k-space segmented fast gradient echo sequence. Measurements of left ventricular volume, ejection fraction and mass obtained with multi-shot echo planar imaging demonstrated close correlation with those obtained with k-space segmented fast gradient echo sequence. Right ventricular volumes obtained with echo planar imaging were significantly higher than those obtained with k-space segmented fast gradient echo sequence. This tendency is considered to be due to differing contrast between right ventricular myocardium and fat tissue observed with echo planar imaging relative to that observed with fast gradient echo sequence, because fat suppression is always performed in echo planar images. Multi-shot echo planar imaging can be a reliable tool for measurement of cardiac functional parameters, although wall motion analysis of the left ventricle requires higher temporal resolution and a short axial section. (K.H.)

  13. MR elastography in primary sclerosing cholangitis: correlating liver stiffness with bile duct strictures and parenchymal changes.

    Science.gov (United States)

    Bookwalter, Candice A; Venkatesh, Sudhakar K; Eaton, John E; Smyrk, Thomas D; Ehman, Richard L

    2018-04-07

    To determine correlation of liver stiffness measured by MR Elastography (MRE) with biliary abnormalities on MR Cholangiopancreatography (MRCP) and MRI parenchymal features in patients with primary sclerosing cholangitis (PSC). Fifty-five patients with PSC who underwent MRI of the liver with MRCP and MRE were retrospectively evaluated. Two board-certified abdominal radiologists in agreement reviewed the MRI, MRCP, and MRE images. The biliary tree was evaluated for stricture, dilatation, wall enhancement, and thickening at segmental duct, right main duct, left main duct, and common bile duct levels. Liver parenchyma features including signal intensity on T2W and DWI, and hyperenhancement in arterial, portal venous, and delayed phase were evaluated in nine Couinaud liver segments. Atrophy or hypertrophy of segments, cirrhotic morphology, varices, and splenomegaly were scored as present or absent. Regions of interest were placed in each of the nine segments on stiffness maps wherever available and liver stiffness (LS) was recorded. Mean segmental LS, right lobar (V-VIII), left lobar (I-III, and IVA, IVB), and global LS (average of all segments) were calculated. Spearman rank correlation analysis was performed for significant correlation. Features with significant correlation were then analyzed for significant differences in mean LS. Multiple regression analysis of MRI and MRCP features was performed for significant correlation with elevated LS. A total of 439/495 segments were evaluated and 56 segments not included in MRE slices were excluded for correlation analysis. Mean segmental LS correlated with the presence of strictures (r = 0.18, p duct strictures. Segments with increased LS show T2 hyperintensity, DWI hyperintensity, and post-contrast hyperenhancement. Global liver stiffness shows a moderate correlation with number of segmental strictures and significantly correlates with spleen stiffness, splenomegaly, and varices.

  14. Potential Hazard to Human Health from Exposure to Fragments of Lead Bullets and Shot in the Tissues of Game Animals

    Science.gov (United States)

    Pain, Deborah J.; Cromie, Ruth L.; Newth, Julia; Brown, Martin J.; Crutcher, Eric; Hardman, Pippa; Hurst, Louise; Mateo, Rafael; Meharg, Andrew A.; Moran, Annette C.; Raab, Andrea; Taggart, Mark A.; Green, Rhys E.

    2010-01-01

    Background Lead is highly toxic to animals. Humans eating game killed using lead ammunition generally avoid swallowing shot or bullets and dietary lead exposure from this source has been considered low. Recent evidence illustrates that lead bullets fragment on impact, leaving small lead particles widely distributed in game tissues. Our paper asks whether lead gunshot pellets also fragment upon impact, and whether lead derived from spent gunshot and bullets in the tissues of game animals could pose a threat to human health. Methodology/Principal Findings Wild-shot gamebirds (6 species) obtained in the UK were X-rayed to determine the number of shot and shot fragments present, and cooked using typical methods. Shot were then removed to simulate realistic practice before consumption, and lead concentrations determined. Data from the Veterinary Medicines Directorate Statutory Surveillance Programme documenting lead levels in raw tissues of wild gamebirds and deer, without shot being removed, are also presented. Gamebirds containing ≥5 shot had high tissue lead concentrations, but some with fewer or no shot also had high lead concentrations, confirming X-ray results indicating that small lead fragments remain in the flesh of birds even when the shot exits the body. A high proportion of samples from both surveys had lead concentrations exceeding the European Union Maximum Level of 100 ppb w.w. (0.1 mg kg−1 w.w.) for meat from bovine animals, sheep, pigs and poultry (no level is set for game meat), some by several orders of magnitude. High, but feasible, levels of consumption of some species could result in the current FAO/WHO Provisional Weekly Tolerable Intake of lead being exceeded. Conclusions/Significance The potential health hazard from lead ingested in the meat of game animals may be larger than previous risk assessments indicated, especially for vulnerable groups, such as children, and those consuming large amounts of game. PMID:20436670

  15. Potential hazard to human health from exposure to fragments of lead bullets and shot in the tissues of game animals.

    Directory of Open Access Journals (Sweden)

    Deborah J Pain

    Full Text Available BACKGROUND: Lead is highly toxic to animals. Humans eating game killed using lead ammunition generally avoid swallowing shot or bullets and dietary lead exposure from this source has been considered low. Recent evidence illustrates that lead bullets fragment on impact, leaving small lead particles widely distributed in game tissues. Our paper asks whether lead gunshot pellets also fragment upon impact, and whether lead derived from spent gunshot and bullets in the tissues of game animals could pose a threat to human health. METHODOLOGY/PRINCIPAL FINDINGS: Wild-shot gamebirds (6 species obtained in the UK were X-rayed to determine the number of shot and shot fragments present, and cooked using typical methods. Shot were then removed to simulate realistic practice before consumption, and lead concentrations determined. Data from the Veterinary Medicines Directorate Statutory Surveillance Programme documenting lead levels in raw tissues of wild gamebirds and deer, without shot being removed, are also presented. Gamebirds containing > or =5 shot had high tissue lead concentrations, but some with fewer or no shot also had high lead concentrations, confirming X-ray results indicating that small lead fragments remain in the flesh of birds even when the shot exits the body. A high proportion of samples from both surveys had lead concentrations exceeding the European Union Maximum Level of 100 ppb w.w. (0.1 mg kg(-1 w.w. for meat from bovine animals, sheep, pigs and poultry (no level is set for game meat, some by several orders of magnitude. High, but feasible, levels of consumption of some species could result in the current FAO/WHO Provisional Weekly Tolerable Intake of lead being exceeded. CONCLUSIONS/SIGNIFICANCE: The potential health hazard from lead ingested in the meat of game animals may be larger than previous risk assessments indicated, especially for vulnerable groups, such as children, and those consuming large amounts of game.

  16. Potential hazard to human health from exposure to fragments of lead bullets and shot in the tissues of game animals.

    Science.gov (United States)

    Pain, Deborah J; Cromie, Ruth L; Newth, Julia; Brown, Martin J; Crutcher, Eric; Hardman, Pippa; Hurst, Louise; Mateo, Rafael; Meharg, Andrew A; Moran, Annette C; Raab, Andrea; Taggart, Mark A; Green, Rhys E

    2010-04-26

    Lead is highly toxic to animals. Humans eating game killed using lead ammunition generally avoid swallowing shot or bullets and dietary lead exposure from this source has been considered low. Recent evidence illustrates that lead bullets fragment on impact, leaving small lead particles widely distributed in game tissues. Our paper asks whether lead gunshot pellets also fragment upon impact, and whether lead derived from spent gunshot and bullets in the tissues of game animals could pose a threat to human health. Wild-shot gamebirds (6 species) obtained in the UK were X-rayed to determine the number of shot and shot fragments present, and cooked using typical methods. Shot were then removed to simulate realistic practice before consumption, and lead concentrations determined. Data from the Veterinary Medicines Directorate Statutory Surveillance Programme documenting lead levels in raw tissues of wild gamebirds and deer, without shot being removed, are also presented. Gamebirds containing > or =5 shot had high tissue lead concentrations, but some with fewer or no shot also had high lead concentrations, confirming X-ray results indicating that small lead fragments remain in the flesh of birds even when the shot exits the body. A high proportion of samples from both surveys had lead concentrations exceeding the European Union Maximum Level of 100 ppb w.w. (0.1 mg kg(-1) w.w.) for meat from bovine animals, sheep, pigs and poultry (no level is set for game meat), some by several orders of magnitude. High, but feasible, levels of consumption of some species could result in the current FAO/WHO Provisional Weekly Tolerable Intake of lead being exceeded. The potential health hazard from lead ingested in the meat of game animals may be larger than previous risk assessments indicated, especially for vulnerable groups, such as children, and those consuming large amounts of game.

  17. Comparison of Multi-shot Models for Short-term Re-identification of People using RGB-D Sensors

    DEFF Research Database (Denmark)

    Møgelmose, Andreas; Bahnsen, Chris; Moeslund, Thomas B.

    2015-01-01

    This work explores different types of multi-shot descriptors for re-identification in an on-the-fly enrolled environment using RGB-D sensors. We present a full re-identification pipeline complete with detection, segmentation, feature extraction, and re-identification, which expands on previous work...... by using multi-shot descriptors modeling people over a full camera pass instead of single frames with no temporal linking. We compare two different multi-shot models; mean histogram and histogram series, and test them each in 3 different color spaces. Both histogram descriptors are assisted by a depth...

  18. Factors which influence on force of boxers` and footballers` shots on the stage of base pre-treatment

    Directory of Open Access Journals (Sweden)

    Nikitenko S.A.

    2011-02-01

    Full Text Available On the stage of base pre-treatment factors which influence on force of shots the hands of boxers and feet of footballers as a criterion of competition activity efficiency are certain. Connections are certain between force of shots by hands and feet. The objective test of the specialized sense determination of boxers` and footballers` shots is offered. It is recommended to develop maximal and explosive force of all parts of sportsman body at implementation preparatory exercises with the further transfer of physical qualities on implementation of the special exercises.

  19. Quantification of pancreatic exocrine function with secretin-enhanced magnetic resonance cholangiopancreatography: normal values and short-term effects of pancreatic duct drainage procedures in chronic pancreatitis. Initial results

    International Nuclear Information System (INIS)

    Bali, M.A.; Sztantics, A.; Metens, T.; Matos, C.; Arvanitakis, M.; Delhaye, M.; Deviere, J.

    2005-01-01

    The aim of this study was to quantify pancreatic exocrine function in normal subjects and in patients with chronic pancreatitis (CP) before and after pancreatic duct drainage procedures (PDDP) with dynamic secretin-enhanced magnetic resonance (MR) cholangiopancreatography (S-MRCP). Pancreatic exocrine secretions [quantified by pancreatic flow output (PFO) and total excreted volume (TEV)] were quantified twice in ten healthy volunteers and before and after treatment in 20 CP patients (18 classified as severe, one as moderate, and one as mild according to the Cambridge classification). PFO and TEV were derived from a linear regression between MR-calculated volumes and time. In all subjects, pancreatic exocrine fluid volume initially increased linearly with time during secretin stimulation. In controls, the mean PFO and TEV were 6.8 ml/min and 97 ml; intra-individual deviations were 0.8 ml/min and 16 ml. In 10/20 patients with impaired exocrine secretions before treatment, a significant increase of PFO and TEV was observed after treatment (P<0.05); 3/20 patients presented post-procedural acute pancreatitis and a reduced PFO. The S-MRCP quantification method used in the present study is reproducible and provides normal values for PFO and TEV in the range of those obtained from previous published intubation studies. The initial results in CP patients have demonstrated non-invasively a significant short-term improvement of PFO and TEV after PDDP. (orig.)

  20. EM algorithm for one-shot device testing with competing risks under exponential distribution

    International Nuclear Information System (INIS)

    Balakrishnan, N.; So, H.Y.; Ling, M.H.

    2015-01-01

    This paper provides an extension of the work of Balakrishnan and Ling [1] by introducing a competing risks model into a one-shot device testing analysis under an accelerated life test setting. An Expectation Maximization (EM) algorithm is then developed for the estimation of the model parameters. An extensive Monte Carlo simulation study is carried out to assess the performance of the EM algorithm and then compare the obtained results with the initial estimates obtained by the Inequality Constrained Least Squares (ICLS) method of estimation. Finally, we apply the EM algorithm to a clinical data, ED01, to illustrate the method of inference developed here. - Highlights: • ALT data analysis for one-shot devices with competing risks is considered. • EM algorithm is developed for the determination of the MLEs. • The estimations of lifetime under normal operating conditions are presented. • The EM algorithm improves the convergence rate

  1. Single-shot readout of accumulation mode Si/SiGe spin qubits using RF reflectometry

    Science.gov (United States)

    Volk, Christian; Martins, Frederico; Malinowski, Filip; Marcus, Charles M.; Kuemmeth, Ferdinand

    Spin qubits based on gate-defined quantum dots are promising systems for realizing quantum computation. Due to their low concentration of nuclear-spin-carrying isotopes, Si/SiGe heterostructures are of particular interest. While high fidelities have been reported for single-qubit and two-qubit gate operations, qubit initialization and measurement times are relatively slow. In order to develop fast read-out techniques compatible with the operation of spin qubits, we characterize double and triple quantum dots confined in undoped Si/Si0.7Ge0.3 heterostructures using accumulation and depletion gates and a nearby RF charge sensor dot. We implement a RF reflectometry technique that allows single-shot charge read-out at integration times on the order of a few μs. We show our recent advancement towards implementing spin qubits in these structures, including spin-selective single-shot read-out.

  2. A generic access to shot-based data for European Tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Signoret, J.; Imbeaux, F. [Association EURATOM-CEA, CEA / DSM / Institut de Recherche sur la Fusion par confinement Magnetique, CEA-Cadarache, 13 - ST-Paul-Lez-Durance (France)

    2009-07-01

    The EFDA Integrated Tokamak Modeling Task Force has defined a data structure offering a generic representation of the properties of physics problems and tokamak subsystem characteristics. It gathers the hardware description, modeling results and data measured during experiments, structured in terms of Consistent Physical Objects (CPOs). A generic tool has been developed to retrieve shot-based data from the various European tokamak databases: Exp2ITM. A tokamak specific XML 'mapping file' is used to map the local data formats to the ITM (Integrated Tokamak Modeling) data format. Exp2ITM is then dynamically generated from the ITM data structure and uses generic procedures to import the shot-based data. Successful tests show we have managed to import into the ITM DB experimental data from Jet and Tore-Supra. This document is a poster. (authors)

  3. An analytical framework for reliability growth of one-shot systems

    International Nuclear Information System (INIS)

    Hall, J. Brian; Mosleh, Ali

    2008-01-01

    In this paper, we introduce a new reliability growth methodology for one-shot systems that is applicable to the case where all corrective actions are implemented at the end of the current test phase. The methodology consists of four model equations for assessing: expected reliability, the expected number of failure modes observed in testing, the expected probability of discovering new failure modes, and the expected portion of system unreliability associated with repeat failure modes. These model equations provide an analytical framework for which reliability practitioners can estimate reliability improvement, address goodness-of-fit concerns, quantify programmatic risk, and assess reliability maturity of one-shot systems. A numerical example is given to illustrate the value and utility of the presented approach. This methodology is useful to program managers and reliability practitioners interested in applying the techniques above in their reliability growth program

  4. Parametric study on single shot peening by dimensional analysis method incorporated with finite element method

    Science.gov (United States)

    Wu, Xian-Qian; Wang, Xi; Wei, Yan-Peng; Song, Hong-Wei; Huang, Chen-Guang

    2012-06-01

    Shot peening is a widely used surface treatment method by generating compressive residual stress near the surface of metallic materials to increase fatigue life and resistance to corrosion fatigue, cracking, etc. Compressive residual stress and dent profile are important factors to evaluate the effectiveness of shot peening process. In this paper, the influence of dimensionless parameters on maximum compressive residual stress and maximum depth of the dent were investigated. Firstly, dimensionless relations of processing parameters that affect the maximum compressive residual stress and the maximum depth of the dent were deduced by dimensional analysis method. Secondly, the influence of each dimensionless parameter on dimensionless variables was investigated by the finite element method. Furthermore, related empirical formulas were given for each dimensionless parameter based on the simulation results. Finally, comparison was made and good agreement was found between the simulation results and the empirical formula, which shows that a useful approach is provided in this paper for analyzing the influence of each individual parameter.

  5. Estimation of fatigue strength enhancement for carburized and shot-peened gears

    Science.gov (United States)

    Inoue, Katsumi; Kato, Masana

    1994-05-01

    An experimental formula has been proposed to estimate the bending fatigue strength of carburized gears from the hardness and the residual stress. The derivation of the formula is briefly reviewed, and the effectiveness of the formula is demonstrated in this article. The comparison with many test results for carburized and shot-peened gears verifies that the formula is effective for the approximate estimation of the fatigue strength. The formula quantitatively shows a way of enhancing fatigue strength, i.e., the increase of hardness and residual stress at the fillet. The strength is enhanced about 300 MPa by an appropriate shot peening, and it can be improved still more by the surface removal by electropolishing.

  6. Shot-noise evidence of fractional quasiparticle creation in a local fractional quantum Hall state.

    Science.gov (United States)

    Hashisaka, Masayuki; Ota, Tomoaki; Muraki, Koji; Fujisawa, Toshimasa

    2015-02-06

    We experimentally identify fractional quasiparticle creation in a tunneling process through a local fractional quantum Hall (FQH) state. The local FQH state is prepared in a low-density region near a quantum point contact in an integer quantum Hall (IQH) system. Shot-noise measurements reveal a clear transition from elementary-charge tunneling at low bias to fractional-charge tunneling at high bias. The fractional shot noise is proportional to T(1)(1-T(1)) over a wide range of T(1), where T(1) is the transmission probability of the IQH edge channel. This binomial distribution indicates that fractional quasiparticles emerge from the IQH state to be transmitted through the local FQH state. The study of this tunneling process enables us to elucidate the dynamics of Laughlin quasiparticles in FQH systems.

  7. Blocking-state influence on shot noise and conductance in quantum dots

    Science.gov (United States)

    Harabula, M.-C.; Ranjan, V.; Haller, R.; Fülöp, G.; Schönenberger, C.

    2018-03-01

    Quantum dots (QDs) investigated through electron transport measurements often exhibit varying, state-dependent tunnel couplings to the leads. Under specific conditions, weakly coupled states can result in a strong suppression of the electrical current, and they are correspondingly called blocking states. Using the combination of conductance and shot noise measurements, we investigate blocking states in carbon nanotube (CNT) QDs. We report negative differential conductance and super-Poissonian noise. The enhanced noise is the signature of electron bunching, which originates from random switches between the strongly and weakly conducting states of the QD. Negative differential conductance appears here when the blocking state is an excited state. In this case, at the threshold voltage where the blocking state becomes populated, the current is reduced. Using a master equation approach, we provide numerical simulations reproducing both the conductance and the shot noise pattern observed in our measurements.

  8. A study on the reliability evaluation of shot peened aluminium alloy using accelerated life test

    International Nuclear Information System (INIS)

    Nam, Ji Hun; Cheong, Seong Kyun; Kang, Min Woo

    2006-01-01

    In this paper, the concept of accelerated life test, which is a popular research field nowadays, is applied to the shot peened material. To predict the efficient and exact room temperature fatigue characteristics from the high temperature fatigue data, the adequate accelerated model is investigated. Ono type rotary bending fatigue tester and high temperature chamber were used for the experiment. Room temperature fatigue lives were predicted by applying accelerated models and doing reliability evaluation. Room temperature fatigue tests were accomplished to check the effectiveness of predicted data and the adequate accelerated life test models were presented by considering errors. Experimental result using Arrhenius model, fatigue limit obtain almost 5.45% of error, inverse power law has about 1.36% of error, so we found that inverse power law is applied well to temperature-life relative of shot peended material

  9. Residual stresses under quasi-static and cyclic loading in shot peened Inconel 718

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmeister, Juergen; Schulze, Volker [Karlsruhe Institute of Technology (KIT), Karlsruhe (Germany). Inst. for Applied Materials; Hessert, Roland; Koenig, Gerhard [MTU Aero Engines, Munich (Germany)

    2012-01-15

    The residual stress state induced by shot peening should be taken into account in the dimensioning of turbine components. Understanding the changes in the residual stress state caused by the application of quasi-static and cyclic loads is a prerequisite. In order to describe the residual stress state after quasi-static loading, several different shot peened Inconel 718 specimens were loaded isothermally up to specific tensile loadings. To analyze the residual stress state after cyclic loading, isothermal low cycle fatigue tests were performed. These tests were stopped after a defined number of cycles. Finally, after the specimens had been subjected to different loads, the surface residual stresses and - for special loadings - the residual stress depth distributions were determined experimentally by using X-ray diffraction. The surface - core model was adapted so that the complete residual stress depth distribution after quasi-static and cyclic loading can now be described. (orig.)

  10. Radiography simulation on single-shot dual-spectrum X-ray for cargo inspection system

    International Nuclear Information System (INIS)

    Gil, Youngmi; Oh, Youngdo; Cho, Moohyun; Namkung, Won

    2011-01-01

    We propose a method to identify materials in the dual energy X-ray (DeX) inspection system. This method identifies materials by combining information on the relative proportions T of high-energy and low-energy X-rays transmitted through the material, and the ratio R of the attenuation coefficient of the material when high-energy are used to that when low energy X-rays are used. In Monte Carlo N-Particle Transport Code (MCNPX) simulations using the same geometry as that of the real container inspection system, this T vs. R method successfully identified tissue-equivalent plastic and several metals. In further simulations, the single-shot mode of operating the accelerator led to better distinguishing of materials than the dual-shot system.

  11. Finite Element Simulation of Shot Peening: Prediction of Residual Stresses and Surface Roughness

    Science.gov (United States)

    Gariépy, Alexandre; Perron, Claude; Bocher, Philippe; Lévesque, Martin

    Shot peening is a surface treatment that consists of bombarding a ductile surface with numerous small and hard particles. Each impact creates localized plastic strains that permanently stretch the surface. Since the underlying material constrains this stretching, compressive residual stresses are generated near the surface. This process is commonly used in the automotive and aerospace industries to improve fatigue life. Finite element analyses can be used to predict residual stress profiles and surface roughness created by shot peening. This study investigates further the parameters and capabilities of a random impact model by evaluating the representative volume element and the calculated stress distribution. Using an isotropic-kinematic hardening constitutive law to describe the behaviour of AA2024-T351 aluminium alloy, promising results were achieved in terms of residual stresses.

  12. Ultrafast T2-weighted single shot spin-echo sequences: applications on abdominal and pelvic pathologies

    International Nuclear Information System (INIS)

    Martin, J.; Martin, C.; Falco, J.; Esteban, L.

    1999-01-01

    The magnetic resonance imaging (MRI) sequences that obtain all the data using a sole excitation pulse of 90 degree centigrade, filling the K space in a single repetition time (TR) is known as snap shot or single shot (SS). The SS sequence based on the rapid acquisition with relaxation enhancement (SS-RARE) method, designed by Hening (1) and a variation of it with a half-Fourier reconstruction (SS-HF-RARE (HASTEL)) (2, 3) are capable of obtaining high contrast images in T2, in very short times, that oscillate between one to several seconds. The clinical application of these sequences to abdominal and pelvic pathologies is increasing, providing and improvement in the contrast resolution, but also in the spatial resolution, with a high relation signal/noise ratio, high contrast and absence of movement artifacts. (Author)

  13. Algorithms for image recovery calculation in extended single-shot phase-shifting digital holography

    Science.gov (United States)

    Hasegawa, Shin-ya; Hirata, Ryo

    2018-04-01

    The single-shot phase-shifting method of image recovery using an inclined reference wave has the advantages of reducing the effects of vibration, being capable of operating in real time, and affording low-cost sensing. In this method, relatively low reference angles compared with that in the conventional method using phase shift between three or four pixels has been required. We propose an extended single-shot phase-shifting technique which uses the multiple-step phase-shifting algorithm and the corresponding multiple pixels which are the same as that of the period of an interference fringe. We have verified the theory underlying this recovery method by means of Fourier spectral analysis and its effectiveness by evaluating the visibility of the image using a high-resolution pattern. Finally, we have demonstrated high-contrast image recovery experimentally using a resolution chart. This method can be used in a variety of applications such as color holographic interferometry.

  14. Single-shot and single-spot measurement of laser ablation threshold for carbon nanotubes

    OpenAIRE

    Lednev, Vasily N.; Pershin, Sergey M.; Obraztsova, Elena D.; Kudryashov, Sergey I.; Bunkin, Alexey F.

    2013-01-01

    A simple and convenient procedure for single-shot, single-spot ablation threshold measurement has been developed. It is based on the employment of cylindrical lens to obtain elliptical Gaussian laser spot. The ablated spot chords which are parallel to the minor axis were measured across the spot major axis which is proportional to the fluence cross-section thus providing wide range dependence of damaged spot size versus fluence in one spot measurement. For both conventional and new-developed ...

  15. Influence of plasma molybdenizing and shot-peening on fretting damage behavior of titanium alloy

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Chang-bin, E-mail: tcbtop@126.com [School of Metallurgy and Engineering, Xi’an University of Architecture and Technology, Xi’an, Shaanxi 710055 (China); Institute of Corrosion and Protection, Northwestern Polytechnical University, Xi’an, Shaanxi 710072 (China); Liu, Dao-xin, E-mail: liudaox@nwpu.edu.cn [Institute of Corrosion and Protection, Northwestern Polytechnical University, Xi’an, Shaanxi 710072 (China); Tang, Bin [Institute of Surface Engineering, Taiyuan University of Technology, Taiyuan Shanxi 030024 (China); Zhang, Xiao-hua [Institute of Corrosion and Protection, Northwestern Polytechnical University, Xi’an, Shaanxi 710072 (China); Qin, Lin [Institute of Surface Engineering, Taiyuan University of Technology, Taiyuan Shanxi 030024 (China); Liu, Cheng-song [Institute of Corrosion and Protection, Northwestern Polytechnical University, Xi’an, Shaanxi 710072 (China)

    2016-12-30

    Highlights: • Plasma molybdenizing increases FW resistance of Ti6Al4V, but reduces its FF life. • Shot-peened plasmamolybdenizing surface enhances FW and FF resistance of Ti6Al4V. • Combined treatment yields low surface-roughness & high hardness gradient distribution. • Combined treatment yields beneficial residual compressive stress & good toughness. • Anti-wear & -fatigue performance improvements for surface engineering applications. - Abstract: Effect of plasma molybdenizing and shot-peening on fretting wear and fretting fatigue behaviors of Ti6Al4V alloy was investigated. The plasma molybdenized layer composed of a dense molybdenum deposition layer and a Mo–Ti solid–solution layer can increase surface hardness by 2.8 times and cause its volume loss by fretting wear to decrease to 1/14 compared with that of the substrate. Plasma molybdenized treatment results in a significant decrease in resistance of the substrate to fretting fatigue. It is ascribed that the molybdenized layer with high hardness yields a low toughness, and its high surface roughness leads to a micro-notched effect. However, proper combination plasma molybdenizing and subsequent shot-peening may enhance the simultaneous fretting fatigue and fretting wear resistance of Ti6Al4V significantly, which can decrease the fretting wear volume loss to 1/27, and may increase the fretting fatigue life by more than 69 times. A synergistic improvement in fretting fatigue of the titanium alloy by combining surface alloying with shot-peening can be achieved. The results indicate that a beneficial residual compressive stress distribution, high surface hardness with suitable hardness gradient distribution, good apparent toughness, relatively low surface roughness, and excellent surface integrity are achieved.

  16. Fracture mechanics analysis of the steam generator tube after shot peening

    International Nuclear Information System (INIS)

    Shin, Kyu In; Jhung, Myung Jo; Choi, Young Hwan; Park, Jai Hak

    2003-01-01

    One of the main degradation of steam generator tubes is stress corrosion cracking induced by residual stress. The resulting damages can cause tube bursting or leakage of the primary water which contained radioactivity. Primary water stress corrosion crack occurs at the location of tube/tubesheet hard rolled transition zone. In order to investigate the effect of shot peening on stress corrosion cracking, stress intensity factors are calculated for the crack which is located in the induced residual stress field

  17. On the Path to SunShot: Emerging Opportunities and Challenges in Financing Solar

    Energy Technology Data Exchange (ETDEWEB)

    Feldman, David [National Renewable Energy Lab. (NREL), Golden, CO (United States); Bolinger, Mark [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-05-01

    This report analyzes solar financing strategies and their role in achieving the U.S. Department of Energy's SunShot goals. Financing is critical to solar deployment, because the costs of solar technologies are paid up front, while their benefits are realized over decades. Solar financing has been shaped by government solar incentives, particularly federal tax incentives, which have spawned complex tax-equity structures that monetize tax benefits for project sponsors who otherwise could not use them efficiently. Although these structures have helped expand solar deployment, they are relatively costly and inefficient. This has spurred solar stakeholders to develop lower-cost financing solutions such as securitization of solar project portfolios, solar-specific loan products, and methods for incorporating residential solar's value into home values. To move solar further toward an unsubsidized SunShot future, additional financial innovation must occur. Development of a larger, more mature U.S. solar industry will likely increase financial transparency and investor confidence, which in turn will enable simpler, lower-cost financing methods. Utility-scale solar might be financed more like conventional generation assets are today, non-residential solar might be financed more like a new roof, and residential solar might be financed more like an expensive appliance. Assuming a constant, SunShot-level installed photovoltaic (PV) system price, such financing innovations could reduce PV's levelized cost of electricity (LCOE) by an estimated 25%-50% compared with historical financing approaches. These results suggest that financing can adapt to changing conditions and might ease the transition away from a reliance on tax incentives while driving solar's LCOE toward the SunShot goals.

  18. Shot-noise at a Fermi-edge singularity: Non-Markovian dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Ubbelohde, N.; Maire, N.; Haug, R. J. [Institut für Festkörperphysik, Leibniz Universität Hannover, Appelstraße 2, D-30167 Hannover (Germany); Roszak, K. [Institute of Physics, Wrocław University of Technology, PL-50370 Wrocław (Poland); Hohls, F. [Physikalisch-Technische Bundesanstalt, D-38116 Braunschweig (Germany); Novotný, T. [Department of Condensed Matter Physics, Faculty of Mathematics and Physics, Charles University, CZ-12116 Prague (Czech Republic)

    2013-12-04

    For an InAs quantum dot we study the current shot noise at a Fermi-edge singularity in low temperature cross-correlation measurements. In the regime of the interaction effect the strong suppression of noise observed at zero magnetic field and the sequence of enhancement and suppression in magnetic field go beyond a Markovian master equation model. Qualitative and quantitative agreement can however be achieved by a generalized master equation model taking non-Markovian dynamics into account.

  19. Bits or Shots in Combat? The Generalized Deitchman Model of Guerrilla Warfare

    OpenAIRE

    Kress, Moshe; MacKay, Niall J.

    2013-01-01

    Operations Research Letters, accepted. We generalize Deitchman's guerrilla warfare model to account for trade-off between intelligence ('bits') and firepower ('shots'). Intelligent targeting leads to aimed fire, absence of intelligence leads to unaimed fire, dependent on targets' density. We propose a new Lanchester-type model that mixes aimed with unaimed fire, the balance between these being determined by quality of information. We derive the model's conserved quantity, and use it ...

  20. Infrared single shot diagnostics for the longitudinal profile of the electron bunches at FLASH

    International Nuclear Information System (INIS)

    Delsim-Hashemi, Hossein

    2008-09-01

    The longitudinal profile of electron bunches plays an important role in the design of single-pass free electron lasers and future linear e + e - colliders. For the free electron laser FLASH in Hamburg, a longitudinal compression scheme is used which results in an asymmetric longitudinal bunch profile with a 'spike'. This 'spike', which has a very high peak current, is used in a high-gain SASE-FEL process to produce high intensity (about 70 μJ) femtosecond photon pulses in the XUV wavelength range. The required high peak current of the electron bunch is realized by confining a large number of electrons in a width, measured in time units, of few tens of femtosecond, making the diagnostics of such bunches a challenge. Furthermore, the operation of facilities such as FLASH shows that single-shot diagnostics is indispensable. It is intuitive to use a time domain method to measure the electron bunch length. However, when the structures present in the bunch profile fall in the femtoseconds range, this is beyond the resolution of time-resolved methods developed so far. In this thesis, a wavelength-domain technique is described that can fulfill both requirements of single shot and high resolution reaching to the femtoseconds range. The amount of charge that is confined in a typical length of several femtoseconds (FWHM of the spike) can be determined by a novel single-shot spectrometer that resolves the coherent radiation (e.g. coherent transition radiation) in the far-infrared and mid-infrared range. Furthermore the extension of this single-shot spectroscopy to shorter wavelengths reaching the near-infrared, makes it possible to investigate the presence of structures in the bunch profile that might correlate or anti-correlate to the SASE intensity. (orig.)

  1. Single-shot speckle reduction in numerical reconstruction of digitally recorded holograms.

    Science.gov (United States)

    Hincapie, Diego; Herrera-Ramírez, Jorge; Garcia-Sucerquia, Jorge

    2015-04-15

    A single-shot method to reduce the speckle noise in the numerical reconstructions of electronically recorded holograms is presented. A recorded hologram with the dimensions N×M is split into S=T×T sub-holograms. The uncorrelated superposition of the individually reconstructed sub-holograms leads to an image with the speckle noise reduced proportionally to the 1/S law. The experimental results are presented to support the proposed methodology.

  2. original papers : Returns to scale in one-shot information processing when hours count

    OpenAIRE

    Catherine de Fontenay; Kieron J. Meagher

    2001-01-01

    The decentralized information processing approach pioneered by Radner and Van Zandt endogenously determines the optimal hierarchy for decision making within an organization. The simplest information processing model is the one-shot problem (one set of information to process) which serves as the testing ground for ever richer descriptions of managers and their tasks. Meagher and Van Zandt observed that an hours-based measure should be used for calculating managerial costs rather than the fixed...

  3. Newsvendor Models for Innovative Products with One-Shot Decision Theory

    OpenAIRE

    Guo, Peijun; Ma, Xiuyan

    2014-01-01

    In this paper, newsvendor problems for innovative products are analyzed. Becausethe product is new, no relevant historical data is available for statistical demand analysis. Insteadof using the probability distribution, the possibility distribution is utilized to characterize theuncertainty of the demand. We consider products whose life cycles are expected to be smallerthan the procurement lead times. Determining optimal order quantities of such products is atypical one-shot decision problem ...

  4. Big Kids Need Shots Too (A Minute of Health with CDC)

    Centers for Disease Control (CDC) Podcasts

    2013-08-29

    At ages 11 through 12, vaccines are recommended to protect against cancers caused by HPV, as well as to prevent tetanus, diphtheria, pertussis, and meningitis. In addition, everyone in the family should get a flu vaccine each year. This podcast discusses the importance of ensuring preteens and teens stay current on their shots.  Created: 8/29/2013 by MMWR.   Date Released: 8/29/2013.

  5. Infrared single shot diagnostics for the longitudinal profile of the electron bunches at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Delsim-Hashemi, Hossein

    2008-09-15

    The longitudinal profile of electron bunches plays an important role in the design of single-pass free electron lasers and future linear e{sup +}e{sup -} colliders. For the free electron laser FLASH in Hamburg, a longitudinal compression scheme is used which results in an asymmetric longitudinal bunch profile with a 'spike'. This 'spike', which has a very high peak current, is used in a high-gain SASE-FEL process to produce high intensity (about 70 {mu}J) femtosecond photon pulses in the XUV wavelength range. The required high peak current of the electron bunch is realized by confining a large number of electrons in a width, measured in time units, of few tens of femtosecond, making the diagnostics of such bunches a challenge. Furthermore, the operation of facilities such as FLASH shows that single-shot diagnostics is indispensable. It is intuitive to use a time domain method to measure the electron bunch length. However, when the structures present in the bunch profile fall in the femtoseconds range, this is beyond the resolution of time-resolved methods developed so far. In this thesis, a wavelength-domain technique is described that can fulfill both requirements of single shot and high resolution reaching to the femtoseconds range. The amount of charge that is confined in a typical length of several femtoseconds (FWHM of the spike) can be determined by a novel single-shot spectrometer that resolves the coherent radiation (e.g. coherent transition radiation) in the far-infrared and mid-infrared range. Furthermore the extension of this single-shot spectroscopy to shorter wavelengths reaching the near-infrared, makes it possible to investigate the presence of structures in the bunch profile that might correlate or anti-correlate to the SASE intensity. (orig.)

  6. Big Kids Need Shots Too (A Cup of Health with CDC)

    Centers for Disease Control (CDC) Podcasts

    Just because your kids are getting older doesn’t mean you can mark vaccines off your “to do” list. Pre-teens and teens need to stay up-to-date on their shots. In this podcast, Dr. Robin Curtis discusses the importance of keeping older children up-to-date for recommended vaccines.

  7. Color-SIFT model: a robust and an accurate shot boundary detection algorithm

    Science.gov (United States)

    Sharmila Kumari, M.; Shekar, B. H.

    2010-02-01

    In this paper, a new technique called color-SIFT model is devised for shot boundary detection. Unlike scale invariant feature transform model that uses only grayscale information and misses important visual information regarding color, here we have adopted different color planes to extract keypoints which are subsequently used to detect shot boundaries. The basic SIFT model has four stages namely scale-space peak selection, keypoint localization, orientation assignment and keypoint descriptor and all these four stages were employed to extract key descriptors in each color plane. The proposed model works on three different color planes and a fusion has been made to take a decision on number of keypoint matches for shot boundary identification and hence is different from the color global scale invariant feature transform that works on quantized images. In addition, the proposed algorithm possess invariance to linear transformation and robust to occlusion and noisy environment. Experiments have been conducted on the standard TRECVID video database to reveal the performance of the proposed model.

  8. Conductivity Profile Determination by Eddy Current for Shot Peened Superalloy Surfaces Toward Residual Stress Assessment

    International Nuclear Information System (INIS)

    Shen, Y.; Lo, C. C. H.; Frishman, A. M.; Lee, C.; Nakagawa, N.

    2007-01-01

    This paper describes an eddy current model-based method for inverting near-surface conductivity deviation profiles of surface treated materials from swept-high frequency eddy current (SHFEC) data. This work forms part of our current research directed towards the development of an electromagnetic nondestructive technique for assessing residual stress of shot-peened superalloy components. The inversion procedure is based on the use of a parameterized function to describe the near-surface conductivity as a function of depth for a shot-peened surface, and the laterally uniform multi-layer theory of Cheng, Dodd and Deeds to calculate the resulting coil impedance deviations. The convergence of the inversion procedure has been tested against synthesized eddy current data. As a demonstration, the conductivity deviation profiles of a series of Inconel 718 specimens, shot peened at various Almen intensities, have been obtained by inversion. Several consistency tests were conducted to examine the reliability of the inverted conductivity profiles. The results show that conductivity deviation profiles can be reliably determined from SHFEC data within the accuracy of the current measurement system

  9. Heuristics guide the implementation of social preferences in one-shot Prisoner's Dilemma experiments.

    Science.gov (United States)

    Capraro, Valerio; Jordan, Jillian J; Rand, David G

    2014-10-28

    Cooperation in one-shot anonymous interactions is a widely documented aspect of human behaviour. Here we shed light on the motivations behind this behaviour by experimentally exploring cooperation in a one-shot continuous-strategy Prisoner's Dilemma (i.e. one-shot two-player Public Goods Game). We examine the distribution of cooperation amounts, and how that distribution varies based on the benefit-to-cost ratio of cooperation (b/c). Interestingly, we find a trimodal distribution at all b/c values investigated. Increasing b/c decreases the fraction of participants engaging in zero cooperation and increases the fraction engaging in maximal cooperation, suggesting a role for efficiency concerns. However, a substantial fraction of participants consistently engage in 50% cooperation regardless of b/c. The presence of these persistent 50% cooperators is surprising, and not easily explained by standard models of social preferences. We present evidence that this behaviour is a result of social preferences guided by simple decision heuristics, rather than the rational examination of payoffs assumed by most social preference models. We also find a strong correlation between play in the Prisoner's Dilemma and in a subsequent Dictator Game, confirming previous findings suggesting a common prosocial motivation underlying altruism and cooperation.

  10. SunShot solar power reduces costs and uncertainty in future low-carbon electricity systems.

    Science.gov (United States)

    Mileva, Ana; Nelson, James H; Johnston, Josiah; Kammen, Daniel M

    2013-08-20

    The United States Department of Energy's SunShot Initiative has set cost-reduction targets of $1/watt for central-station solar technologies. We use SWITCH, a high-resolution electricity system planning model, to study the implications of achieving these targets for technology deployment and electricity costs in western North America, focusing on scenarios limiting carbon emissions to 80% below 1990 levels by 2050. We find that achieving the SunShot target for solar photovoltaics would allow this technology to provide more than a third of electric power in the region, displacing natural gas in the medium term and reducing the need for nuclear and carbon capture and sequestration (CCS) technologies, which face technological and cost uncertainties, by 2050. We demonstrate that a diverse portfolio of technological options can help integrate high levels of solar generation successfully and cost-effectively. The deployment of GW-scale storage plays a central role in facilitating solar deployment and the availability of flexible loads could increase the solar penetration level further. In the scenarios investigated, achieving the SunShot target can substantially mitigate the cost of implementing a carbon cap, decreasing power costs by up to 14% and saving up to $20 billion ($2010) annually by 2050 relative to scenarios with Reference solar costs.

  11. [The forensic medical characteristics of the entrance bullet holes created by the shots from pneumatic rifles].

    Science.gov (United States)

    Legin, G A; Bondarchuk, A O; Perebetjuk, A N

    2015-01-01

    The objective of the present study was to compare the injurious action of three types of the bullets for the pneumatic weapons shot from different distances using the Gamo pump air pistol and the BAM B22-1 pneumatic rifle. The following four kinds of the bullets were tested: "the fireball", "Luman cap 0.3", "Luman Field Target 0.68" and "DIABOLO". It was experimentally shown that the injurious action of the bullets fired from the same distance from the pneumatic weapons depends on the type of both the bullet and the weapon, as well as the properties of the target material. Specifically, the action of bullets fired from the piston pneumatic rifle remained stable whereas that of the bullets shot from the gas-balloon air pistol decreased as the gas was exhausted. The studies by the contact-diffusion method have demonstrated that the entrance bullet holes created by the shots from pneumatic weapons are surrounded by dispersed metal particles which makes it possible to estimate the shooting distance. Moreover, the bullets fired from the pneumatic weapons leave the muzzle face imprint on certain target materials.

  12. Eddy Current Nondestructive Residual Stress Assessment in Shot-Peened Nickel-Base Superalloys

    International Nuclear Information System (INIS)

    Blodgett, M.P.; Yu, F.; Nagy, P.B.

    2005-01-01

    Shot peening and other mechanical surface enhancement methods improve the fatigue resistance and foreign-object damage tolerance of metallic components by introducing beneficial near-surface compressive residual stresses and hardening the surface. However, the fatigue life improvement gained via surface enhancement is not explicitly accounted for in current engine component life prediction models because of the lack of accurate and reliable nondestructive methods that could verify the presence of compressive near-surface residual stresses in shot-peened hardware. In light of its frequency-dependent penetration depth, the measurement of eddy current conductivity has been suggested as a possible means to allow the nondestructive evaluation of subsurface residual stresses in surface-treated components. This technique is based on the so-called piezoresistivity effect, i.e., the stress-dependence of electrical resistivity. We found that, in contrast with most other materials, surface-treated nickel-base superalloys exhibit an apparent increase in electrical conductivity at increasing inspection frequencies, i.e., at decreasing penetration depths. Experimental results are presented to illustrate that the excess frequency-dependent apparent eddy current conductivity of shot-peened nickel-base superalloys can be used to estimate the absolute level and penetration depth of the compressive residual stress layer both before and after partial thermal relaxation

  13. Single shot diffraction of picosecond 8.7-keV x-ray pulses

    Directory of Open Access Journals (Sweden)

    F. H. O’Shea

    2012-02-01

    Full Text Available We demonstrate multiphoton, single shot diffraction images of x rays produced by inverse Compton scattering a high-power CO_{2} laser from a relativistic electron beam, creating a pulse of 8.7 keV x rays. The tightly focused, relatively high peak brightness electron beam and high photon density from the 2 J CO_{2} laser yielded 6×10^{7} x-ray photons over the full opening angle in a single shot. Single shot x-ray diffraction is performed by passing the x rays though a vertical slit and on to a flat silicon (111 crystal. 10^{2} diffracted photons were detected. The spectrum of the detected x rays is compared to simulation. The diffraction and detection of 10^{2} x rays is a key step to a more efficient time resolved diagnostic in which the number of observed x rays might reach 10^{4}; enabling a unique, flexible x-ray source as a sub-ps resolution diagnostic for studying the evolution of chemical reactions, lattice deformation and melting, and magnetism.

  14. Lead shot from hunting as a source of lead in human blood

    International Nuclear Information System (INIS)

    Johansen, Poul; Pedersen, Henning Sloth; Asmund, Gert; Riget, Frank

    2006-01-01

    This study investigates the relationship between the intake of birds hunted with lead shot and the lead concentration in human blood. Fifty adult men from Nuuk, Greenland took part in the study. From September 2003 to June 2004 they regularly gave blood samples and recorded how many birds they ate. We found a clear relationship between the number of bird meals and blood lead and also a clear seasonal variation. The concentration was highest in mid-winter when bird consumption is at its highest. Blood lead was low (15 μg/L, mean concentration) among the participants reporting not eating birds. Among those reporting to eat birds regularly, blood lead was significantly higher, up to 128 μg/L (mean concentration). Concentrations depended on the frequency of bird meals: the more the bird meals, the higher the resulting blood lead. This clear relationship points to lead shot as the dominating lead source to people in Greenland. - Birds hunted with lead shot and consumed are a source of lead in human blood

  15. Unconditional violation of the shot-noise limit in photonic quantum metrology

    Science.gov (United States)

    Slussarenko, Sergei; Weston, Morgan M.; Chrzanowski, Helen M.; Shalm, Lynden K.; Verma, Varun B.; Nam, Sae Woo; Pryde, Geoff J.

    2017-11-01

    Interferometric phase measurement is widely used to precisely determine quantities such as length, speed and material properties1-3. Without quantum correlations, the best phase sensitivity Δ ϕ achievable using n photons is the shot-noise limit, Δ ϕ =1 /√{n }. Quantum-enhanced metrology promises better sensitivity, but, despite theoretical proposals stretching back decades3,4, no measurement using photonic (that is, definite photon number) quantum states has truly surpassed the shot-noise limit. Instead, all such demonstrations, by discounting photon loss, detector inefficiency or other imperfections, have considered only a subset of the photons used. Here, we use an ultrahigh-efficiency photon source and detectors to perform unconditional entanglement-enhanced photonic interferometry. Sampling a birefringent phase shift, we demonstrate precision beyond the shot-noise limit without artificially correcting our results for loss and imperfections. Our results enable quantum-enhanced phase measurements at low photon flux and open the door to the next generation of optical quantum metrology advances.

  16. Single-shot echo-planar imaging of multiple sclerosis: effects of varying echo time

    International Nuclear Information System (INIS)

    Wolansky, L.J.; Chong, S.; Liu, W.C.; Kang, E.; Simpson, S.W.; Karimi, S.; Akbari, H.

    1999-01-01

    Our aim was to determine the relative merits of short and long echo times (TE) with single-shot echo-planar imaging for imaging cerebral lesions such as multiple sclerosis. We examined seven patients with clinically definite multiple sclerosis were imaged at 1.5 T. Patients were scanned with spin-echo, single-shot echo-planar imaging, using TEs of 45, 75, 105, and 135 ms. Region of interest (ROI) measurements were performed on 36 lesions at or above the level of the corona radiata. The mean image contrast (IC) was highest (231.1) for a TE of 45 ms, followed by 75 ms (218.9), 105 ms (217.9), and 135 ms (191.6). When mean contrast-to-noise ratios (C/N) were compared, the value was again highest (29.7) for TE 45 ms, followed by 75 ms (28.9), 105 ms (28.5), and 135 ms (26.3). In a lesion-by-lesion comparison, TE 45 ms had the highest IC and C/N in the largest number of cases (50 % and 47.2 %, respectively). IC and C/N for TE 45 ms were superior to those of 75 ms in 64 % and 58 %, respectively. These results support the use of relatively short TEs for single-shot echo-planar imaging in the setting of cerebral lesions such as multiple sclerosis. (orig.) (orig.)

  17. Golf in the Wind: Exploring the Effect of Wind on the Accuracy of Golf Shots

    Science.gov (United States)

    Yaghoobian, Neda; Mittal, Rajat

    2015-11-01

    Golf play is highly dependent on the weather conditions with wind being the most significant factor in the unpredictability of the ball landing position. The direction and strength of the wind alters the aerodynamic forces on a ball in flight, and consequently its speed, distance and direction of travel. The fact that local wind conditions on any particular hole change over times-scales ranging all the way from a few seconds to minutes, hours and days introduces an element of variability in the ball trajectory that is not understood. Any such analysis is complicated by the effect of the local terrestrial and vegetation topology, as well as the inherent complexity of golf-ball aerodynamics. In the current study, we use computational modeling to examine the unpredictability of the shots under different wind conditions over Hole-12 at the Augusta National Golf Club, where the Masters Golf Tournament takes place every year. Despite this being the shortest hole on the course, the presence of complex vegetation canopy around this hole introduces a spatial and temporal variability in wind conditions that evokes uncertainty and even fear among professional golfers. We use our model to examine the effect of wind direction and wind-speed on the accuracy of the golf shots at this hole and use the simulations to determine the key aerodynamic factors that affect the accuracy of the shot.

  18. Cross-correlation measurement of quantum shot noise using homemade transimpedance amplifiers

    International Nuclear Information System (INIS)

    Hashisaka, Masayuki; Ota, Tomoaki; Yamagishi, Masakazu; Fujisawa, Toshimasa; Muraki, Koji

    2014-01-01

    We report a cross-correlation measurement system, based on a new approach, which can be used to measure shot noise in a mesoscopic conductor at milliKelvin temperatures. In contrast to other measurement systems in which high-speed low-noise voltage amplifiers are commonly used, our system employs homemade transimpedance amplifiers (TAs). The low input impedance of the TAs significantly reduces the crosstalk caused by unavoidable parasitic capacitance between wires. The TAs are designed to have a flat gain over a frequency band from 2 kHz to 1 MHz. Low-noise performance is attained by installing the TAs at a 4 K stage of a dilution refrigerator. Our system thus fulfills the technical requirements for cross-correlation measurements: low noise floor, high frequency band, and negligible crosstalk between two signal lines. Using our system, shot noise generated at a quantum point contact embedded in a quantum Hall system is measured. The good agreement between the obtained shot-noise data and theoretical predictions demonstrates the accuracy of the measurements

  19. The Effect of Introducing a Smaller and Lighter Basketball on Female Basketball Players’ Shot Accuracy

    Science.gov (United States)

    Podmenik, Nadja; Leskošek, Bojan; Erčulj, Frane

    2012-01-01

    Our study examined whether the introduction of a smaller and lighter basketball (no. 6) affected the accuracy of female basketball players’ shots at the basket. The International Basketball Federation (FIBA) introduced a size 6 ball in the 2004/2005 season to improve the efficiency and accuracy of technical elements, primarily shots at the basket. The sample for this study included 573 European female basketball players who were members of national teams that had qualified for the senior women’s European championships in 2001, 2003, 2005 and 2007. A size 7 (larger and heavier) basketball was used by 286 players in 1,870 matches, and a size 6 basketball was used by 287 players in 1,966 matches. The players were categorised into three playing positions: guards, forwards and centres. The results revealed that statistically significant changes by year occurred only in terms of the percentage of successful free throws. With the size 6 basketball, this percentage decreased. Statistically significant differences between the playing positions were observed in terms of the percentage of field goals worth three points (between guards and forwards) and two points (between guards and centres). The results show that the introduction of the size 6 basketball did not lead to improvement in shooting accuracy (the opposite was found for free throws), although the number of three-point shots increased. PMID:23486286

  20. Using deep neural networks to augment NIF post-shot analysis

    Science.gov (United States)

    Humbird, Kelli; Peterson, Luc; McClarren, Ryan; Field, John; Gaffney, Jim; Kruse, Michael; Nora, Ryan; Spears, Brian

    2017-10-01

    Post-shot analysis of National Ignition Facility (NIF) experiments is the process of determining which simulation inputs yield results consistent with experimental observations. This analysis is typically accomplished by running suites of manually adjusted simulations, or Monte Carlo sampling surrogate models that approximate the response surfaces of the physics code. These approaches are expensive and often find simulations that match only a small subset of observables simultaneously. We demonstrate an alternative method for performing post-shot analysis using inverse models, which map directly from experimental observables to simulation inputs with quantified uncertainties. The models are created using a novel machine learning algorithm which automates the construction and initialization of deep neural networks to optimize predictive accuracy. We show how these neural networks, trained on large databases of post-shot simulations, can rigorously quantify the agreement between simulation and experiment. This work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  1. Lead shot from hunting as a source of lead in human blood

    Energy Technology Data Exchange (ETDEWEB)

    Johansen, Poul [National Environmental Research Institute, Frederiksborgvej 399, DK-4000 Roskilde (Denmark)]. E-mail: poj@dmu.dk; Pedersen, Henning Sloth [Primary Health Care Center, DK-3900 Nuuk (Greenland); Asmund, Gert [National Environmental Research Institute, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Riget, Frank [National Environmental Research Institute, Frederiksborgvej 399, DK-4000 Roskilde (Denmark)

    2006-07-15

    This study investigates the relationship between the intake of birds hunted with lead shot and the lead concentration in human blood. Fifty adult men from Nuuk, Greenland took part in the study. From September 2003 to June 2004 they regularly gave blood samples and recorded how many birds they ate. We found a clear relationship between the number of bird meals and blood lead and also a clear seasonal variation. The concentration was highest in mid-winter when bird consumption is at its highest. Blood lead was low (15 {mu}g/L, mean concentration) among the participants reporting not eating birds. Among those reporting to eat birds regularly, blood lead was significantly higher, up to 128 {mu}g/L (mean concentration). Concentrations depended on the frequency of bird meals: the more the bird meals, the higher the resulting blood lead. This clear relationship points to lead shot as the dominating lead source to people in Greenland. - Birds hunted with lead shot and consumed are a source of lead in human blood.

  2. Geochemistry of Eagle Ford group source rocks and oils from the first shot field area, Texas

    Science.gov (United States)

    Edman, Janell D.; Pitman, Janet K.; Hammes, Ursula

    2010-01-01

    Total organic carbon, Rock-Eval pyrolysis, and vitrinite reflectance analyses performed on Eagle Ford Group core and cuttings samples from the First Shot field area, Texas demonstrate these samples have sufficient quantity, quality, and maturity of organic matter to have generated oil. Furthermore, gas chromatography and biomarker analyses performed on Eagle Ford Group oils and source rock extracts as well as weight percent sulfur analyses on the oils indicate the source rock facies for most of the oils are fairly similar. Specifically, these source rock facies vary in lithology from shales to marls, contain elevated levels of sulfur, and were deposited in a marine environment under anoxic conditions. It is these First Shot Eagle Ford source facies that have generated the oils in the First Shot Field. However, in contrast to the generally similar source rock facies and organic matter, maturity varies from early oil window to late oil window in the study area, and these maturity variations have a pronounced effect on both the source rock and oil characteristics. Finally, most of the oils appear to have been generated locally and have not experienced long distance migration. 

  3. Effect of high energy shot peening pressure on the stress corrosion cracking of the weld joint of 304 austenitic stainless steel

    International Nuclear Information System (INIS)

    Zhiming, Lu; Laimin, Shi; Shenjin, Zhu; Zhidong, Tang; Yazhou, Jiang

    2015-01-01

    The weld joint of 304 stainless steel is treated using high energy shot peening(HESP) with various shot peening pressures. The grain size and metallographic microstructure of the specimen surface layer are analyzed using the X-ray diffraction method, and the surface hardness is measured. Slow strain rate tension tests are then performed to investigate the effect of shot peening pressure on the stress corrosion sensitivity. The results show that in the surface layer of the specimen, the grain refinement, hardness and the strain-induced plastic deformation all increase with the increasing shot peening pressure. Martensitic transformation is observed in the surface layer after being treated with HESP. The martensite phase ratio is found to increase with increasing shot peening pressure. The result also shows that the effects of the shot peening treatment on the stress corrosion sensitivity index depend on the shot peening pressure. When the shot peening pressure is less than 0.4 MPa, the grain refinement effect plays the main role, and the stress corrosion sensitivity index decreases with the increasing shot peening pressure. In contrast, when the shot peening pressure is higher than 0.4 MPa, the martensite transformation effect plays the main role, the stress corrosion sensitivity index increases with increasing shot peening pressure

  4. SHOT PUT O’BRIAN TECHNIQUE, EXTENDING THE ANALYSIS OF TECHNIQUE FROM FOUR TO SIX PHASES WITH THE DESCRIPTION

    Directory of Open Access Journals (Sweden)

    Zlatan Saračević

    2011-09-01

    Full Text Available Due to the complexity of the motion, shot put technique is described in phases for easier analysis, easer learning of technique and error correction. It is complete so that in its implementation the transition from phase to phase is not noticed. In aforementioned and described phases of O'Brian spinal shot put technique a large distance, emptiness and disconnection appear between the initial position phase and a phase of overtaking the device, which in the training methods and training technique in primary and secondary education, as well as for students and athletes beginners in shot put represents a major problem regarding connecting, training and technique advancement. Therefore, this work is aimed at facilitating the methods of training of shot put technique, extending from four to six phases, which have been described and include the complete O'Brian technique.

  5. Integration of Heat Treatment with Shot Peening of 17-4 Stainless Steel Fabricated by Direct Metal Laser Sintering

    Science.gov (United States)

    AlMangour, Bandar; Yang, Jenn-Ming

    2017-11-01

    Direct metal laser sintering (DMLS) is a promising powder-based additive manufacturing process for fabrication of near-net-shape parts. However, the typically poor fatigue performance of DMLS parts must be addressed for use in demanding industrial applications. Post-treatment can be applied to enhance the performance of such components. Earlier attempts at inducing grain refinement through severe plastic deformation of part surfaces using shot peening improved the physical and mechanical properties of metals without chemical alteration. However, heat treatment can modify the surface-hardening effects attained by shot peening. Hence, we examined the feasibility of applying shot peening combined with heat treatment to improve the performance of DMLS-fabricated 17-4 stainless steel parts through microstructural evolution studies and hardness measurements. Compared to a specimen treated only by shot peening, the sample exposed to additional heat treatment showed increased hardness due to aging of the dominant phase.

  6. The impact of sound technology on the distribution of shot lengths in Hollywood cinema, 1920 to 1933

    Directory of Open Access Journals (Sweden)

    Nick Redfern

    2012-11-01

    Full Text Available The impact of sound technology on Hollywood is analysed through looking at the median shot lengths of silent films from the 1920s (n = 54 and early sound films (n = 106. The results show a large increase in the median shot lengths with the introduction of sound (Mann Whitney U = 554.0, Z = -8.33, p = <0.01, PS = 0.0968, estimated to be 2.0s (95% CI: 1.6, 2.4. The dispersion of shot lengths measured using the robust estimator Qn shows a similarly large increase in the dispersion of shot lengths with the transition to sound (Mann Whitney U = 319.0, Z = -9.18, p = <0.01, PS = 0.0557, estimated to be 2.0s (95% CI: 1.7, 2.4.

  7. Kinetic energy of ions produced with first-, second-, and multi-shot femtosecond laser ablation on a solid surface

    International Nuclear Information System (INIS)

    Kobayashi, Tohru; Kato, Toshiyuki; Kurata-Nishimura, Mizuki; Matsuo, Yukari; Kawai, Jun; Motobayashi, Tohru; Hayashizaki, Yoshihide

    2007-01-01

    We report that the kinetic energy of samarium (Sm) atom and Sm + ion produced by femtosecond laser ablation of solid samarium is strongly dependent on the number of ablation laser shots in the range from 1 to 10. By ablating the fresh surface (i.e. 1st shot), we find the kinetic energy of both Sm and Sm + ion to be the largest (24 and 250 eV, respectively). Almost 10 times larger kinetic energy of Sm + ion than that of Sm clearly indicates the contribution of Coulomb explosion in the acceleration process. From the second shot, kinetic energies of Sm and Sm + ion are lower than those of the first shot and almost constant (ca. 12 and 80 eV, respectively). This behaviour suggests the change in the nature of the solid surface after femtosecond laser ablation, which can be explained by the amorphization of ablated sample surface reported in recent studies

  8. Finite element modelling of shot peening process: Prediction of the compressive residual stresses, the plastic deformations and the surface integrity

    International Nuclear Information System (INIS)

    Frija, M.; Hassine, T.; Fathallah, R.; Bouraoui, C.; Dogui, A.

    2006-01-01

    This paper presents a numerical simulation of the shot peening process using finite element method. The majority of the controlling parameters of the process have been taken into account. The shot peening loading has been characterised by using energy equivalence between the dynamic impact and a static indentation of a peening shot in the treated surface. The behaviour of the subjected material is supposed to be elastic plastic with damage. An integrated law of the damage proposed by Lemaitre and Chaboche has been used. The proposed model leads to obtain the residual stress, the plastic deformation profiles and the surface damage. An application on a shot peened Ni-based super alloy Waspaloy has been carried out. The comparison of the residual stresses, obtained by X-ray diffraction method and by finite element calculation, shows a good correlation. The in-depth profile of the plastic deformations and the superficial damage values are in good agreement with the experimental observations

  9. Self-Consistent Theory of Shot Noise Suppression in Ballistic Conductors

    Science.gov (United States)

    Bulashenko, O. M.; Rubí, J. M.; Kochelap, V. A.

    Shot-noise measurements become a fundamental tool to probe carrier interactions in mesoscopic systems [1]. A matter of particular interest is the significance of Coulomb interaction which may keep nearby electrons more regularly spaced rather than strictly at random and lead to the noise reduction. That effect occurs in different physical situations. Among them are charge-limited ballistic transport, resonant tunneling, single-electron tunneling, etc. In this communication we address the problem of Coulomb correlations in ballistic conductors under the space-charge-limited transport conditions, and present for the first time a semiclassical self-consistent theory of shot noise in these conductors by solving analytically the kinetic equation coupled self-consistently with a Poisson equation. Basing upon this theory, exact results for current noise in a two-terminal ballistic conductor under the action of long-range Coulomb correlations has been derived. The noise reduction factor (in respect to the uncorrelated value) is obtained in a closed analytical form for a full range of biases ranging from thermal to shot-noise limits which describe perfectly the results of the Monte Carlo simulations for a nondegenerate electron gas [2]. The magnitude of the noise reduction exceeds 0.01, which is of interest from the point of view of possible applications. Using these analytical results one may estimate a relative contribution to the noise from different groups of carriers (in energy space and/or real space) and to investigate in great detail the correlations between different groups of carriers. This leads us to suggest an electron energy spectroscopy experiment to probe the Coulomb correlations in ballistic conductors. Indeed, while the injected carriers are uncorrelated, those in the volume of the conductor are strongly correlated, as follows from the derived formulas for the fluctuation of the distribution function. Those correlations may be observed experimentally by

  10. AN EFFECT OF SHOT PEENING ON GROWTH AND RETARDATION OF PHYSICALLY SHORT FATIGUE CRACKS IN AN AIRCRAFT Al-ALLOY

    Directory of Open Access Journals (Sweden)

    Ivo Černý

    2009-11-01

    Full Text Available Results of an investigation of effect of shot peening on development of physically short fatigue crack in an aircraft V-95 Al-alloy, which is of a similar type as 7075 alloy, are described and discussed in the paper. The first part deals with adaptation and verification of direct current potential drop method for detection and measurement of short crack initiation and growth. The specific material and quite large dimensions of flat specimens with side necking of a low stress concentration factor had to be considered when position of electrodes was specified and the measurement method verified. The specimen type and dimensions were proposed taking account of the investigation of shot peening effects. Physically short fatigue cracks of the length from 0.2 mm to more than 3 mm, most of them between 0.8 – 1.5 mm, were prepared under high cycle fatigue loading of a constant nominal stress amplitude plus/minus 160 MPa. Specimens with existing short fatigue cracks were shot peened using two different groups of parameters. Development of crack growth after shot peening was measured and compared with crack growth in specimens without shot peening. Retardation of crack growth was significant particularly with cracks shorter than 2 mm. For the specific stress amplitude, evaluated results enable to estimate threshold length of defects, which after the application of shot peening will be reliably arrested.

  11. Assessment of surface hardening effects from shot peening on a Ni-based alloy using electron backscatter diffraction techniques

    International Nuclear Information System (INIS)

    Child, D.J.; West, G.D.; Thomson, R.C.

    2011-01-01

    An electron backscatter diffraction (EBSD)-based tool is described to assess the depth of strain-hardening effects of shot-peening treatments applied to the Ni-based superalloy, Udimet (copy right) alloy 720Li. The method consists of a statistical analysis of a number of data points from each grain scanned based on the grain orientation spread and their relative position from the shot-peened edge. The output is a quantitative measure of the depth of strain-hardening effects. The tool is used at various shot-peening intensities to demonstrate the ability to distinguish between these changes, using a range of intensities from 4 to 10 Almen. An increase in shot-peening intensity is observed to increase the depth of strain-hardening effects in the alloy. A comparison with residual stress measurements using X-ray diffraction for the same material shows that the strain-hardened depth determined by EBSD extends to approximately half the distance of the residual stress present due to shot peening. A comparison is also made with predicted profiles from the Peenstress SM model and subsequent microhardness testing. A positive correlation is observed between strained hardened depth and surface roughness of the peened samples. In each case, the increases in surface roughness and strain-hardened depth diminish toward the upper end of the shot-peening intensity range studied for this alloy.

  12. Reducing Pb poisoning in birds and Pb exposure in game meat consumers: the dual benefit of effective Pb shot regulation.

    Science.gov (United States)

    Mateo, Rafael; Vallverdú-Coll, Núria; López-Antia, Ana; Taggart, Mark A; Martínez-Haro, Monica; Guitart, Raimon; Ortiz-Santaliestra, Manuel E

    2014-02-01

    The use of lead (Pb) ammunition in the form of shot pellets has been identified as a Pb exposure risk in wildlife and their human consumers. We explore the hypothesis that Pb shot ban enforcement reduces the risk of avian Pb poisoning as well as Pb exposure in game meat consumers. We assessed compliance with a partial ban on Pb shot commencing in 2003 by examination of 937 waterbirds harvested by hunters between 2007 and 2012 in the Ebro delta (Spain). Prevalence of Pb shot ingestion was determined, as were Pb concentrations in liver and muscle tissue to evaluate the potential for Pb exposure in game meat consumers. Hunted birds with only embedded Pb shot (no steel) declined from 26.9% in 2007-08 to meat (0.1μg/g wet weight) in the 2008-09 season, when Pb shot ingestion prevalence was also at a minimum (5.1%). Effective restrictions in Pb ammunition use have a dual benefit since this reduces Pb exposure for game meat consumers due to embedded ammunition as well as reducing Pb poisoning in waterbirds. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Full report of laser doppler velocimetry (Het-V) data, results , and analysis for pRad shot 0632

    Energy Technology Data Exchange (ETDEWEB)

    Tupa, Dale [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Tainter, Amy Marie [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-21

    This was a collaborative shot with AWE investigators Paul Willis-Patel, David Bell, Seth Grant, David Tarr, and James Richley. The shot was assembled in Los Alamos, after which David Bell set up the probe holder and finalized the alignment. The probe holder location and configuration was modified from previous years to make room for the laser illuminated visible imaging diagnostic. The LANL pRad PDV team was Dale Tupa, Amy Tainter, and Patrick Medina. This shot had three PDV probes: one aimed at the center, one aimed at a feature, one aimed at the reverse side of the shot. The shot also had 9 points of a spectroscopy diagnostic. The pRad team helped set up and field the spectroscopy, but did not help with any data analysis. (The support documentation for the PDV results includes a timing map for the spectroscopy.) Please direct questions on the velocimetry to Dale Tupa or Amy Tainter. The shot radiographs were classified, but the data from the optical diagnostics are not.

  14. Flu Shot

    Science.gov (United States)

    Flu is a respiratory infection caused by a number of viruses. Most people with the flu get better on their own. But it can ... cause complications and sometimes even death. Getting the flu vaccine every year is the best way to ...

  15. A Gene Family Coding for Salivary Proteins (SHOT) of the Polyphagous Spider Mite Tetranychus urticae Exhibits Fast Host-Dependent Transcriptional Plasticity.

    Science.gov (United States)

    Jonckheere, Wim; Dermauw, Wannes; Khalighi, Mousaalreza; Pavlidi, Nena; Reubens, Wim; Baggerman, Geert; Tirry, Luc; Menschaert, Gerben; Kant, Merijn R; Vanholme, Bartel; Van Leeuwen, Thomas

    2018-01-01

    The salivary protein repertoire released by the herbivorous pest Tetranychus urticae is assumed to hold keys to its success on diverse crops. We report on a spider mite-specific protein family that is expanded in T. urticae. The encoding genes have an expression pattern restricted to the anterior podocephalic glands, while peptide fragments were found in the T. urticae secretome, supporting the salivary nature of these proteins. As peptide fragments were identified in a host-dependent manner, we designated this family as the SHOT (secreted host-responsive protein of Tetranychidae) family. The proteins were divided in three groups based on sequence similarity. Unlike TuSHOT3 genes, TuSHOT1 and TuSHOT2 genes were highly expressed when feeding on a subset of family Fabaceae, while expression was depleted on other hosts. TuSHOT1 and TuSHOT2 expression was induced within 24 h after certain host transfers, pointing toward transcriptional plasticity rather than selection as the cause. Transfer from an 'inducer' to a 'noninducer' plant was associated with slow yet strong downregulation of TuSHOT1 and TuSHOT2, occurring over generations rather than hours. This asymmetric on and off regulation points toward host-specific effects of SHOT proteins, which is further supported by the diversity of SHOT genes identified in Tetranychidae with a distinct host repertoire.

  16. Electrochemical and morphological analyses on the titanium surface modified by shot blasting and anodic oxidation processes

    Energy Technology Data Exchange (ETDEWEB)

    Szesz, Eduardo M., E-mail: eszesz@neoortho.com.br [Neoortho Research Institute, Rua Ângelo Domingos Durigan, 607-Cascatinha, CEP 82025-100 Curitiba, PR (Brazil); Pereira, Bruno L., E-mail: brnl7@hotmail.com [Physics Department, Universidade Federal do Paraná, 81531-980 Curitiba, PR (Brazil); Kuromoto, Neide K., E-mail: kuromoto@fisica.ufpr.br [Physics Department, Universidade Federal do Paraná, 81531-980 Curitiba, PR (Brazil); Marino, Claudia E.B., E-mail: claudiamarino@yahoo.com [Mechanical Engineering Department, Universidade Federal do Paraná, 81531-980 Curitiba, PR (Brazil); Souza, Gelson B. de, E-mail: gelsonbs@uepg.br [Physics Department, Universidade Estadual de Ponta Grossa, 84051-510 Ponta Grossa, PR (Brazil); Soares, Paulo, E-mail: pa.soares@pucpr.br [Mechanical Engineering Department, Pontifícia Universidade Católica do Paraná, 80215-901 Curitiba, PR (Brazil)

    2013-01-01

    In recent years, many surface modification processes have been developed in order to induce the osseointegration on titanium surface and thus to improve the implants' biocompatibility. In this work, Ti surface has been modified by shot blasting followed by anodic oxidation process in order to associate the good surface characteristics of both processes to obtain a rough and porous surface able to promote the titanium surface bioactivity. Commercially pure titanium (grade 2) plates were used on the surface treatments that were as follows: Shot blasting (SB) performed using alumina (Al{sub 2}O{sub 3}) particles, and anodic oxidation (AO) using NaOH electrolyte. The morphology, structural changes and the open-circuit potentials (OCP) of the surfaces were analyzed. It can be observed that an increase on the roughness of the blasted surface and a rough and porous surface happens after the AO process. The anodic film produced is thin and followed the blasted surface topography. It can be observed that there are small pores with regular shape covering the entire surface. X-ray diffraction results showed the presence of the anatase and rutile phases on the blasted and anodized surface after heat treatment at 600 °C/1 h. Concerning electrochemical measurements, when the different samples were submitted to open-circuit conditions in a physiological electrolyte, the protective effect increases with the oxidation process due to the oxide layer. When the surface was blasted, the OCP was more negative when compared with the Ti surface without surface treatments. - Highlights: ► A combination of shot blasting and anodic oxidation surface treatments is proposed. ► Both processes produced an increase in roughness compared to the polished surface. ► The combination of processes produced a rough and porous surface. ► Open circuit results show that the protective effect increases with oxidation process. ► The combination of processes presents the better results in this

  17. Accurate estimation of camera shot noise in the real-time

    Science.gov (United States)

    Cheremkhin, Pavel A.; Evtikhiev, Nikolay N.; Krasnov, Vitaly V.; Rodin, Vladislav G.; Starikov, Rostislav S.

    2017-10-01

    Nowadays digital cameras are essential parts of various technological processes and daily tasks. They are widely used in optics and photonics, astronomy, biology and other various fields of science and technology such as control systems and video-surveillance monitoring. One of the main information limitations of photo- and videocameras are noises of photosensor pixels. Camera's photosensor noise can be divided into random and pattern components. Temporal noise includes random noise component while spatial noise includes pattern noise component. Temporal noise can be divided into signal-dependent shot noise and signal-nondependent dark temporal noise. For measurement of camera noise characteristics, the most widely used methods are standards (for example, EMVA Standard 1288). It allows precise shot and dark temporal noise measurement but difficult in implementation and time-consuming. Earlier we proposed method for measurement of temporal noise of photo- and videocameras. It is based on the automatic segmentation of nonuniform targets (ASNT). Only two frames are sufficient for noise measurement with the modified method. In this paper, we registered frames and estimated shot and dark temporal noises of cameras consistently in the real-time. The modified ASNT method is used. Estimation was performed for the cameras: consumer photocamera Canon EOS 400D (CMOS, 10.1 MP, 12 bit ADC), scientific camera MegaPlus II ES11000 (CCD, 10.7 MP, 12 bit ADC), industrial camera PixeLink PL-B781F (CMOS, 6.6 MP, 10 bit ADC) and video-surveillance camera Watec LCL-902C (CCD, 0.47 MP, external 8 bit ADC). Experimental dependencies of temporal noise on signal value are in good agreement with fitted curves based on a Poisson distribution excluding areas near saturation. Time of registering and processing of frames used for temporal noise estimation was measured. Using standard computer, frames were registered and processed during a fraction of second to several seconds only. Also the

  18. Fourier Analysis of Single-Shot Dual-Energy X-ray Imaging Characteristics

    International Nuclear Information System (INIS)

    Kim, Jun Woo; Kim, Dong Woon; Kim, Ho Kyung

    2016-01-01

    The sandwich detector was realized by stacking two scintillator-based flat-panel detectors (FPDs) between which an intermediate copper (Cu) filter layer was placed to further enhance spectral energy separation. As a result, the proper selection of filter material and its thickness could be a trade-off between the extent of energy separation (hence, DE image quality) and image noise due to reduction in the number of x-ray quanta reaching the rear FPD. Although the conventional kVp-switching dual-shot method showed better image qualities than the single-shot method because of larger spectral energy separation, the motion-artifact-free DE image with reasonably good image quality was a potential prospect of the single-shot method. For the reliable and better use of the sandwich detector for specific imaging applications, the sandwich detector should be optimally designed with a proper selection of scintillator material and thickness in each detector layer (i.e. the front and rear detectors), and aforementioned intermediate filter material and thickness. It is noted that glue is used to adhere the fragile photodiode array onto the ceramic substrate and these glue patterns are apparent in the rear and DE images. The glue pattern in the rear image comes from the front FPD. Unlike the conventional ESF as shown in Fig. 3(a), the ESF obtained from the subtracted image showed an enhancement as shown in Fig. 3(b). Consequently, the MTF obtained from the subtraction ESF showed a bandpass filter characteristic, as shown in Fig. 3(c), unlike the conventional low-pass filter characteristic (i.e., monotonic decrease of MTF value with increasing the spatial frequency). This MTF characteristic is due to the subtraction of two images with different spatial resolving powers (i.e., different thicknesses of phosphors between the front and rear detectors) as can be seen in unsharp masking digital image processing, which subtracts Gaussian-blurred image from the original image

  19. Partial Fourier techniques in single-shot cross-term spatiotemporal encoded MRI.

    Science.gov (United States)

    Zhang, Zhiyong; Frydman, Lucio

    2018-03-01

    Cross-term spatiotemporal encoding (xSPEN) is a single-shot approach with exceptional immunity to field heterogeneities, the images of which faithfully deliver 2D spatial distributions without requiring a priori information or using postacquisition corrections. xSPEN, however, suffers from signal-to-noise ratio penalties due to its non-Fourier nature and due to diffusion losses-especially when seeking high resolution. This study explores partial Fourier transform approaches that, acting along either the readout or the spatiotemporally encoded dimensions, reduce these penalties. xSPEN uses an orthogonal (e.g., z) gradient to read, in direct space, the low-bandwidth (e.g., y) dimension. This substantially changes the nature of partial Fourier acquisitions vis-à-vis conventional imaging counterparts. A suitable theoretical analysis is derived to implement these procedures, along either the spatiotemporally or readout axes. Partial Fourier single-shot xSPEN images were recorded on preclinical and human scanners. Owing to their reduction in the experiments' acquisition times, this approach provided substantial sensitivity gains vis-à-vis previous implementations for a given targeted in-plane resolution. The physical origins of these gains are explained. Partial Fourier approaches, particularly when implemented along the low-bandwidth spatiotemporal dimension, provide several-fold sensitivity advantages at minimal costs to the execution and processing of the single-shot experiments. Magn Reson Med 79:1506-1514, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  20. Ultrafast bold fMRI using single-shot spin-echo echo planar imaging

    Directory of Open Access Journals (Sweden)

    Boujraf Said

    2009-01-01

    Full Text Available The choice of imaging parameters for functional MRI can have an impact on the accuracy of functional localization by affecting the image quality and the degree of blood oxygenation-dependent (BOLD contrast achieved. By improving sampling efficiency, parallel acquisition techniques such as sensitivity encoding (SENSE have been used to shorten readout trains in single-shot (SS echo planar imaging (EPI. This has been applied to susceptibility artifact reduction and improving spatial resolution. SENSE together with single-shot spin-echo (SS-SE imaging may also reduce off-resonance artifacts. The goal of this work was to investigate the BOLD response of a SENSE-adapted SE-EPI on a three Tesla scanner. Whole-brain fMRI studies of seven healthy right hand-dominant volunteers were carried out in a three Tesla scanner. fMRI was performed using an SS-SE EPI sequence with SENSE. The data was processed using statistical parametric mapping. Both, group and individual subject data analyses were performed. Individual average percentage and maximal percentage signal changes attributed to the BOLD effect in M1 were calculated for all the subjects as a function of echo time. Corresponding activation maps and the sizes of the activated clusters were also calculated. Our results show that susceptibility artifacts were reduced with the use of SENSE; and the acquired BOLD images were free of the typical quadrature artifacts of SS-EPI. Such measures are crucial at high field strengths. SS SE-EPI with SENSE offers further benefits in this regard and is more specific for oxygenation changes in the microvasculature bed. Functional brain activity can be investigated with the help of single-shot spin echo EPI using SENSE at high magnetic fields.

  1. Fourier Analysis of Single-Shot Dual-Energy X-ray Imaging Characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jun Woo; Kim, Dong Woon; Kim, Ho Kyung [Pusan National University, Busan (Korea, Republic of)

    2016-05-15

    The sandwich detector was realized by stacking two scintillator-based flat-panel detectors (FPDs) between which an intermediate copper (Cu) filter layer was placed to further enhance spectral energy separation. As a result, the proper selection of filter material and its thickness could be a trade-off between the extent of energy separation (hence, DE image quality) and image noise due to reduction in the number of x-ray quanta reaching the rear FPD. Although the conventional kVp-switching dual-shot method showed better image qualities than the single-shot method because of larger spectral energy separation, the motion-artifact-free DE image with reasonably good image quality was a potential prospect of the single-shot method. For the reliable and better use of the sandwich detector for specific imaging applications, the sandwich detector should be optimally designed with a proper selection of scintillator material and thickness in each detector layer (i.e. the front and rear detectors), and aforementioned intermediate filter material and thickness. It is noted that glue is used to adhere the fragile photodiode array onto the ceramic substrate and these glue patterns are apparent in the rear and DE images. The glue pattern in the rear image comes from the front FPD. Unlike the conventional ESF as shown in Fig. 3(a), the ESF obtained from the subtracted image showed an enhancement as shown in Fig. 3(b). Consequently, the MTF obtained from the subtraction ESF showed a bandpass filter characteristic, as shown in Fig. 3(c), unlike the conventional low-pass filter characteristic (i.e., monotonic decrease of MTF value with increasing the spatial frequency). This MTF characteristic is due to the subtraction of two images with different spatial resolving powers (i.e., different thicknesses of phosphors between the front and rear detectors) as can be seen in unsharp masking digital image processing, which subtracts Gaussian-blurred image from the original image.

  2. Avulsion of the Lesser Trochanter Following a Shot Put Sport Session

    Directory of Open Access Journals (Sweden)

    Mohamed H. Grissa

    2017-03-01

    Full Text Available Avulsion of the lesser trochanter is an uncommon injury. In children and adolescents it usually occurs as a sports injury via traumatic avulsion of the psoas major tendon. In adults, isolated fractures of the lesser trochanter are most commonly pathological due to metastatic tumor invasion of the proximal femur. This case report documents how a 14-year-old boy, who presented with an avulsion of the lesser trochanter of the proximal femur following a seemingly atraumatic shot put session at a track and field event, was diagnosed and successfully treated with a conservative approach.

  3. Tunnel barrier and noncollinear magnetization effects on shot noise in ferromagnetic/semiconductor/ferromagnetic heterojunctions

    International Nuclear Information System (INIS)

    An Xingtao; Liu Jianjun

    2008-01-01

    Based on the scattering approach, we investigate transport properties of electrons in a one-dimensional waveguide that contains a ferromagnetic/semiconductor/ferromagnetic heterojunction and tunnel barriers in the presence of Rashba and Dresselhaus spin-orbit interactions. We simultaneously consider significant quantum size effects, quantum coherence, Rashba and Dresselhaus spin-orbit interactions and noncollinear magnetizations. It is found that the tunnel barrier plays a decisive role in the transmission coefficient and shot noise of the ballistic spin electron transport through the heterojunction. When the small tunnel barriers are considered, the transport properties of electrons are quite different from those without tunnel barriers

  4. Low voltage excess noise and shot noise in YBCO bicrystal junctions

    DEFF Research Database (Denmark)

    Constantinian, K.Y.; Ovsyannikov, G.A.; Borisenko, I.V.

    2002-01-01

    The spectral density of background noise emitted by symmetric bicrystal YBaCuO Josephson junctions on sapphire substrates have been measured by a low noise cooled HEMT amplifier for bias voltages up to V approximate to 50 mV. At relatively low voltages V noise rise has been...... registered. At large bias voltages V > 30 mV a clear dependence of noise power. exactly coinciding to the asymptote of the Schottky shot noise function, has been observed for the first time. Experimental results are discussed in terms of multiple Andreev reflections which may take place in d...

  5. Recalling ISX shot data files from the off-line archive

    International Nuclear Information System (INIS)

    Stanton, J.S.

    1981-02-01

    This document describes a set of computer programs designed to allow access to ISX shot data files stored on off-line disk packs. The programs accept user requests for data files and build a queue of end requests. When an operator is available to mount the necessary disk packs, the system copies the requested files to an on-line disk area. The program runs on the Fusion Energy Division's DECsystem-10 computer. The request queue is implemented under the System 1022 data base management system. The support programs are coded in MACRO-10 and FORTRAN-10

  6. Shot-noise-limited monitoring and phase locking of the motion of a single trapped ion.

    Science.gov (United States)

    Bushev, P; Hétet, G; Slodička, L; Rotter, D; Wilson, M A; Schmidt-Kaler, F; Eschner, J; Blatt, R

    2013-03-29

    We perform a high-resolution real-time readout of the motion of a single trapped and laser-cooled Ba+ ion. By using an interferometric setup, we demonstrate a shot-noise-limited measurement of thermal oscillations with a resolution of 4 times the standard quantum limit. We apply the real-time monitoring for phase control of the ion motion through a feedback loop, suppressing the photon recoil-induced phase diffusion. Because of the spectral narrowing in the phase-locked mode, the coherent ion oscillation is measured with a resolution of about 0.3 times the standard quantum limit.

  7. Big Kids Need Shots Too (A Cup of Health with CDC)

    Centers for Disease Control (CDC) Podcasts

    2013-08-29

    Just because your kids are getting older doesn’t mean you can mark vaccines off your “to do” list. Pre-teens and teens need to stay up-to-date on their shots. In this podcast, Dr. Robin Curtis discusses the importance of keeping older children up-to-date for recommended vaccines.  Created: 8/29/2013 by MMWR.   Date Released: 8/29/2013.

  8. ["A shot at the father: a student's assault". Sigmund Freud and the case of Ernst Haberl].

    Science.gov (United States)

    Aichhorn, Thomas

    2014-01-01

    In the fall of 1922, the Freud family was involved in a criminal case: The son of Mathilde Freud's nursing sister, Ernst Haberl, had shot at his father. With the help of August Aichhorn the Viennese Juvenile Court's social assistance department was engaged on behalf of the young man. Freud commissioned the lawyer Valentin Teirich to defend him in court. The Viennese dailies reported the deed and the trial extensively (Haberl was acquitted). That a comment published in the Neue Freie Presse was written by Freud himself, as Teirich believed, is, according to Anna Freud, highly improbable.

  9. Effect of Heart rate on Basketball Three-Point Shot Accuracy

    OpenAIRE

    Luca P. Ardigò; Goran Kuvacic; Antonio D. Iacono; Giacomo Dascanio; Johnny Padulo; Johnny Padulo

    2018-01-01

    The three-point shot (3S) is a fundamental basketball skill used frequently during a game, and is often a main determinant of the final result. The aim of the study was to investigate the effect of different metabolic conditions, in terms of heart rates, on 3S accuracy (3S%) in 24 male (Under 17) basketball players (age 16.3 ± 0.6 yrs). 3S performance was specifically investigated at different heart rates. All sessions consisted of 10 consecutive 3Ss from five different significant field spot...

  10. Single-shot secure quantum network coding on butterfly network with free public communication

    Science.gov (United States)

    Owari, Masaki; Kato, Go; Hayashi, Masahito

    2018-01-01

    Quantum network coding on the butterfly network has been studied as a typical example of quantum multiple cast network. We propose a secure quantum network code for the butterfly network with free public classical communication in the multiple unicast setting under restricted eavesdropper’s power. This protocol certainly transmits quantum states when there is no attack. We also show the secrecy with shared randomness as additional resource when the eavesdropper wiretaps one of the channels in the butterfly network and also derives the information sending through public classical communication. Our protocol does not require verification process, which ensures single-shot security.

  11. The effects of localised fatigue on upper extremity jump shot kinematics and kinetics in team handball.

    Science.gov (United States)

    Plummer, Hillary A; Oliver, Gretchen D

    2017-01-01

    Team handball is a popular sport worldwide that requires numerous throws to be made throughout the course of a game. Because of the upper extremity demands of repetitive throwing, it is possible that fatigue can alter the mechanics of a shot. The purpose of this study was to determine the influence of localised fatigue on jump shot kinematics and kinetics. Eleven male team handball players (23.1 ± 3.1 years; 185.1 ± 8.3 cm; 89.7 ± 12.2 kg) volunteered. An electromagnetic tracking system was used to examine the jump shot prior to and following localised fatigue. The fatiguing protocol consisted of throwing a 2.2 kg medicine ball into a rebounder until volitional fatigue. No significant kinematic or kinetic differences were observed following fatigue. Shoulder external rotation was -74.8 ± 14.9° prior to and -79.0 ± 14.7° following fatigue at MER. Scapula, external rotation at ball release (BR) prior to fatigue was -2.2 ± 7.0° and -3.2 ± 11.1° following fatigue. Scapular internal rotation, at maximum shoulder internal rotation (MIR), changed from 18.4 ± 11.2° to 20.4 ± 11.8°. Ball velocity decreased from19.8 m · s -1 to 18.8 m · s -1 (P = 0.12). Accuracy percentage in the pre-fatigue trials was 60.8 ± 14.1% and 52.8 ± 12.7% following fatigue (P = 0.20). While no significant changes were observed, it is possible that other fatiguing protocols that more closely represent the aerobic and throwing demands of the sport may have a greater effect on the kinematics and kinetics of the jump shot.

  12. On the effectiveness of surface severe plastic deformation by shot peening at cryogenic temperature

    Science.gov (United States)

    Novelli, M.; Fundenberger, J.-J.; Bocher, P.; Grosdidier, T.

    2016-12-01

    The effect of cryogenic temperature (CT) on the graded microstructures obtained by severe shot peening using surface mechanical attrition treatment (SMAT) was investigated for two austenitic steels that used different mechanisms for assisting plastic deformation. For the metastable 304L steel, the depth of the hardened region increases because CT promotes the formation of strain induced martensite. Comparatively, for the 310S steel that remained austenitic, the size of the subsurface affected region decreases because of the improved strength of the material at CT but the fine twinned nanostructures results in significant top surface hardening.

  13. Residual stress stability and alternating bending strength of AISI 4140 after shot peening and successive annealing

    Energy Technology Data Exchange (ETDEWEB)

    Menig, R.; Schulze, V.; Voehringer, O. [Inst. fuer Werkstoffkunde I, Univ. of Karlsruhe (TH), Karlsruhe (Germany)

    2002-07-01

    Increases of residual stress stability and alternating bending strength of shot peened AISI 4140 are obtained by successive annealing treatments. This is caused by static strain aging effects, which lead to pinning of dislocations by carbon atoms and finest carbides. It will be shown that by short-time annealing of a quenched and tempered AISI 4140 it is possible to maximize the positive effect of static strain aging, while minimizing the detrimental effect of thermal residual stress relaxation, which was measured by X-ray diffraction method. Static strain aging effects were also found to be responsible for an increase of the quasi static and cyclic surface yield strengths. (orig.)

  14. Light emission and finite-frequency shot noise in molecular junctions: from tunneling to contact

    DEFF Research Database (Denmark)

    Lu, Jing Tao; Christensen, Rasmus Bjerregaard; Brandbyge, Mads

    2013-01-01

    Scanning tunneling microscope induced light emission from an atomic or molecular junction has been probed from the tunneling to contact regime in recent experiments. There, the measured light emission yields suggest a strong correlation with the high-frequency current/charge fluctuations. We show...... that this is consistent with the established theory in the tunneling regime, by writing the finite-frequency shot noise as a sum of inelastic transitions between different electronic states. Based on this, we develop a practical scheme to perform calculations on realistic structures using nonequilibrium Green's functions...

  15. Reduction of shot noise in an interference gravitational-wave detector

    International Nuclear Information System (INIS)

    Troitskii, Yu V

    2001-01-01

    The characteristics of a Michelson interferometer whose arms are formed by reflection Fabri - Perot interferometers (FPIs), which is designed for measurements of ultra-small displacements, are studied. It is shown that the recent advances in the mirror coating technology along with the optimisation of the parameters of the FPI mirrors makes it possible to greatly improve the ratio of the signal to the shot noise. Optimal transmission of the front FPI mirror is approximately equal to the absorption coefficient of the mirrors. (laser applications and other topics in quantum electronics)

  16. Single-shot femtosecond-pulsed phase-shifting digital holography.

    Science.gov (United States)

    Kakue, Takashi; Itoh, Seiya; Xia, Peng; Tahara, Tatsuki; Awatsuji, Yasuhiro; Nishio, Kenzo; Ura, Shogo; Kubota, Toshihiro; Matoba, Osamu

    2012-08-27

    Parallel phase-shifting digital holography is capable of three-dimensional measurement of a dynamically moving object with a single-shot recording. In this letter, we demonstrated a parallel phase-shifting digital holography using a single femtosecond light pulse whose central wavelength and temporal duration were 800 nm and 96 fs, respectively. As an object, we set spark discharge in atmospheric pressure air induced by applying a high voltage to between two electrodes. The instantaneous change in phase caused by the spark discharge was clearly reconstructed. The reconstructed phase image shows the change of refractive index of air was -3.7 × 10(-4).

  17. Effect of laser shot peening on precipitation hardened aluminum alloy 6061-T6 using low energy laser

    Science.gov (United States)

    Sathyajith, S.; Kalainathan, S.

    2012-03-01

    Mechanical properties of engineering material can be improved by introducing compressive residual stress on the material surface and refinement of their microstructure. Variety of mechanical process such as shot peening, water jet peening, ultrasonic peening, laser shot peening were developed in the last decades on this contrast. Among these, lasers shot peening emerged as a novel industrial treatment to improve the crack resistance of turbine blades and the stress corrosion cracking (SCC) of austenic stainless steel in power plants. In this study we successfully performed laser shot peening on precipitation hardened aluminum alloy 6061-T6 with low energy (300 mJ, 1064 nm) Nd:YAG laser using different pulse densities of 22 pulses/mm 2 and 32 pulses/mm 2. Residual stress evaluation based on X-ray diffraction sin 2 ψ method indicates a maximum of 190% percentage increase on surface compressive stress. Depth profile of micro-hardness shows the impact of laser generated shock wave up to 1.2 mm from the surface. Apart from that, the crystalline size and micro-strain on the laser shot peened surfaces have been investigated and compared with the unpeened surface using X-ray diffraction in conjunction with line broadening analysis through the Williamson-Hall plot.

  18. The influence of shot peening on the fatigue and corrosion properties of an austenitic stainless steel for surgical implants

    International Nuclear Information System (INIS)

    Wieser, H.

    1997-01-01

    To roughen the surface surgical implants are often peened with granular media. Local depressions formed by the peening process lower the fatigue and corrosion resistance. This negative effect can be avoided by shot peening with spherical particles, which leads to high compressive residual stresses near the surface. As it is shown in this work several kinds of surface flaws like overlappings, cracks and sharp edged notches are formed by shot peening. Their form and depth and the reasons for their occurrence are not well known since the commonly used measurements with a stylus tip cannot detect them. For this reason sharp edged metallographic sections which represent the surface profile are examined. In order to estimate the maximum depth of these depressions a statistical model was developed applying the theory of statistics of extreme values. The influence of shot peening on fatigue and corrosion behavior is examined by fatigue tests in air, physiological NaCl-solution and by electrochemical corrosion tests. An increase of the fatigue resistance in air can be obtained by shot peening with large ceramic particles (0,6 mm to 0,8 mm) and low peening pressure since these conditions generate smaller surface flaws than with small balls and high pressure. In physiological NaCl-solution the fatigue resistance decreases after the shot peening treatment. This can be related to crevices formed by overlappings and cracks. Removal by subsequent electrolytical polishing the corrosion fatigue resistance increases again. (author)

  19. Experiments and Analysis of Close-Shot Identification of On-Branch Citrus Fruit with RealSense

    Directory of Open Access Journals (Sweden)

    Jizhan Liu

    2018-05-01

    Full Text Available Fruit recognition based on depth information has been a hot topic due to its advantages. However, the present equipment and methods cannot meet the requirements of rapid and reliable recognition and location of fruits in close shot for robot harvesting. To solve this problem, we propose a recognition algorithm for citrus fruit based on RealSense. This method effectively utilizes depth-point cloud data in a close-shot range of 160 mm and different geometric features of the fruit and leaf to recognize fruits with a intersection curve cut by the depth-sphere. Experiments with close-shot recognition of six varieties of fruit under different conditions were carried out. The detection rates of little occlusion and adhesion were from 80–100%. However, severe occlusion and adhesion still have a great influence on the overall success rate of on-branch fruits recognition, the rate being 63.8%. The size of the fruit has a more noticeable impact on the success rate of detection. Moreover, due to close-shot near-infrared detection, there was no obvious difference in recognition between bright and dark conditions. The advantages of close-shot limited target detection with RealSense, fast foreground and background removal and the simplicity of the algorithm with high precision may contribute to high real-time vision-servo operations of harvesting robots.

  20. Effect of shot peening treatment in the behavior of residual stress in duplex stainless steel during medium cycle fatigue; Efeito do tratamento de shot peening no comportamento das tensoes residuais em aco inoxidavel duplex durante fadiga de medio ciclo

    Energy Technology Data Exchange (ETDEWEB)

    Pedrosa, Peter D.S.; Rebello, Joao Marcos A. [Coordenacao dos Programas de Pos-Graduacao de Engenharia (PEMM/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Metalurgica e de Materiais; Fonseca, Maria P. Cindra, E-mail: mcindra@vm.uff.b [Universidade Federal Fluminense (PGMEC/UFF), Niteroi, RJ (Brazil). Escola de Engenharia. Programa de Pos-Graduacao em Engenharia Mecanica

    2010-07-01

    The lifetime of duplex stainless steel parts experiencing cyclic fatigue is directly influenced by the residual stresses present in the ferrite and austenite phases. The motivation for this work was to analyze the behaviour of the residual stresses fields introduced by shot peening treatment in both phases, in the sample surface as in the subsurface layers, in low fatigue cycles, using the X-rays diffraction technique. The results shows that the compressive residual stresses introduced by the shot peening treatment in both phases improved fatigue life of the material. However, the cyclical loads produce partial or total relief in these residual stresses fields. It was verified that the shot peening process induced the formation of microcracks only in the ferrite phase. The largest variations in the total compressive residual stresses fields also occurred in this phase. The samples surfaces were analyzed by scanning electron microscopy. (author)

  1. On-shot characterization of single plasma mirror temporal contrast improvement

    Science.gov (United States)

    Obst, L.; Metzkes-Ng, J.; Bock, S.; Cochran, G. E.; Cowan, T. E.; Oksenhendler, T.; Poole, P. L.; Prencipe, I.; Rehwald, M.; Rödel, C.; Schlenvoigt, H.-P.; Schramm, U.; Schumacher, D. W.; Ziegler, T.; Zeil, K.

    2018-05-01

    We report on the setup and commissioning of a compact recollimating single plasma mirror (PM) for temporal contrast enhancement at the Draco 150 TW laser during laser-proton acceleration experiments. The temporal contrast with and without PM is characterized single-shot by means of self-referenced spectral interferometry with extended time excursion at unprecedented dynamic and temporal range. This allows for the first single-shot measurement of the PM trigger point, which is interesting for the quantitative investigation of the complex pre-plasma formation process at the surface of the target used for proton acceleration. As a demonstration of high contrast laser plasma interaction we present proton acceleration results with ultra-thin liquid crystal targets of ∼ 1 μm down to 10 nm thickness. Focus scans of different target thicknesses show that highest proton energies are reached for the thinnest targets at best focus. This indicates that the contrast enhancement is effective such that the acceleration process is not limited by target pre-expansion induced by laser light preceding the main laser pulse.

  2. Frequency-Domain Tomography for Single-shot, Ultrafast Imaging of Evolving Laser-Plasma Accelerators

    Science.gov (United States)

    Li, Zhengyan; Zgadzaj, Rafal; Wang, Xiaoming; Downer, Michael

    2011-10-01

    Intense laser pulses propagating through plasma create plasma wakefields that often evolve significantly, e.g. by expanding and contracting. However, such dynamics are known in detail only through intensive simulations. Laboratory visualization of evolving plasma wakes in the ``bubble'' regime is important for optimizing and scaling laser-plasma accelerators. Recently snap-shots of quasi-static wakes were recorded using frequency-domain holography (FDH). To visualize the wake's evolution, we have generalized FDH to frequency-domain tomography (FDT), which uses multiple probes propagating at different angles with respect to the pump pulse. Each probe records a phase streak, imprinting a partial record of the evolution of pump-created structures. We then topographically reconstruct the full evolution from all phase streaks. To prove the concept, a prototype experiment visualizing nonlinear index evolution in glass is demonstrated. Four probes propagating at 0, 0.6, 2, 14 degrees to the index ``bubble'' are angularly and temporally multiplexed to a single spectrometer to achieve cost-effective FDT. From these four phase streaks, an FDT algorithm analogous to conventional CT yields a single-shot movie of the pump's self-focusing dynamics.

  3. Differences Between Perceived and Registered Behavior of Basketball Coaches After Shot

    Directory of Open Access Journals (Sweden)

    Benjamin Longarela Pérez

    2015-09-01

    Full Text Available This research examines the behavior of youth club basketball coaches after a shot in real-competition situations. Six licensed coaches of the Spanish Basketball Federation took part in this study; all the teams competed in the Galician league (Spain in the 2010/2011 and 2011/2012 seasons. There were five men’s teams and one women’s team, with players between 11 and 17 years old. To record the behavior, a new instrument was used based mainly on the Coach Behaviour Assessment System (CBAS, which also incorporates some of the adjustments made in the SOCE (Sistema Observación Conductas Entrenador developed by Montero. The instrument was designed to analyze the behavior of coaches after their players have taken shots. In total, 38 official matches were analyzed. Registered behaviors were compared with auto-perceived data in the same situation. From the results obtained, significant differences between the registered behavior and the auto-perception of the coaches are evident.

  4. Feasibility of one-shot-per-crystal structure determination using Laue diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Cornaby, Sterling [School of Applied and Engineering Physics, Cornell University, Ithaca, New York (United States); CHESS (Cornell High Energy Synchrotron Source), Cornell University, Ithaca, New York (United States); Szebenyi, Doletha M. E. [MacCHESS (Macromolecular Diffraction Facilities at CHESS), Cornell University, Ithaca, New York (United States); Smilgies, Detlef-M. [CHESS (Cornell High Energy Synchrotron Source), Cornell University, Ithaca, New York (United States); Schuller, David J.; Gillilan, Richard; Hao, Quan [MacCHESS (Macromolecular Diffraction Facilities at CHESS), Cornell University, Ithaca, New York (United States); Bilderback, Donald H., E-mail: dhb2@cornell.edu [School of Applied and Engineering Physics, Cornell University, Ithaca, New York (United States); CHESS (Cornell High Energy Synchrotron Source), Cornell University, Ithaca, New York (United States)

    2010-01-01

    Structure determination was successfully carried out using single Laue exposures from a group of lysozyme crystals. The Laue method may be a viable option for collection of one-shot-per-crystal data from microcrystals. Crystal size is an important factor in determining the number of diffraction patterns which may be obtained from a protein crystal before severe radiation damage sets in. As crystal dimensions decrease this number is reduced, eventually falling to one, at which point a complete data set must be assembled using data from multiple crystals. When only a single exposure is to be collected from each crystal, the polychromatic Laue technique may be preferable to monochromatic methods owing to its simultaneous recording of a large number of fully recorded reflections per image. To assess the feasibility of solving structures using single Laue images from multiple crystals, data were collected using a ‘pink’ beam at the CHESS D1 station from groups of lysozyme crystals with dimensions of the order of 20–30 µm mounted on MicroMesh grids. Single-shot Laue data were used for structure determination by molecular replacement and correct solutions were obtained even when as few as five crystals were used.

  5. Feasibility of one-shot-per-crystal structure determination using Laue diffraction

    International Nuclear Information System (INIS)

    Cornaby, Sterling; Szebenyi, Doletha M. E.; Smilgies, Detlef-M.; Schuller, David J.; Gillilan, Richard; Hao, Quan; Bilderback, Donald H.

    2010-01-01

    Structure determination was successfully carried out using single Laue exposures from a group of lysozyme crystals. The Laue method may be a viable option for collection of one-shot-per-crystal data from microcrystals. Crystal size is an important factor in determining the number of diffraction patterns which may be obtained from a protein crystal before severe radiation damage sets in. As crystal dimensions decrease this number is reduced, eventually falling to one, at which point a complete data set must be assembled using data from multiple crystals. When only a single exposure is to be collected from each crystal, the polychromatic Laue technique may be preferable to monochromatic methods owing to its simultaneous recording of a large number of fully recorded reflections per image. To assess the feasibility of solving structures using single Laue images from multiple crystals, data were collected using a ‘pink’ beam at the CHESS D1 station from groups of lysozyme crystals with dimensions of the order of 20–30 µm mounted on MicroMesh grids. Single-shot Laue data were used for structure determination by molecular replacement and correct solutions were obtained even when as few as five crystals were used

  6. Evaluation of shot peening on the fatigue strength of anodized Ti-6Al-4V alloy

    Directory of Open Access Journals (Sweden)

    Costa Midori Yoshikawa Pitanga

    2006-01-01

    Full Text Available The increasingly design requirements for modern engineering applications resulted in the development of new materials with improved mechanical properties. Low density, combined with excellent weight/strength ratio as well as corrosion resistance, make the titanium attractive for application in landing gears. Fatigue control is a fundamental parameter to be considered in the development of mechanical components. The aim of this research is to analyze the fatigue behavior of anodized Ti-6Al-4V alloy and the influence of shot peening pre treatment on the experimental data. Axial fatigue tests (R = 0.1 were performed, and a significant reduction in the fatigue strength of anodized Ti-6Al-4V was observed. The shot peening superficial treatment, which objective is to create a compressive residual stress field in the surface layers, showed efficiency to increase the fatigue life of anodized material. Experimental data were represented by S-N curves. Scanning electron microscopy technique (SEM was used to observe crack origin sites.

  7. Anode performance of boron-doped graphites prepared from shot and sponge cokes

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Tao; Luo, Ruiying [School of Science, Beihang University, Beijing 100083 (China); Yoon, Seong-Ho; Mochida, Isao [Institute for Materials Chemistry and Engineering, Kyushu University, Kasuga, Fukuoka 816-8580 (Japan)

    2010-03-15

    The structures and anode performances of graphitized pristine and boron-doped shot and sponge cokes have been comparatively studied by means of scanning electron microscope (SEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and galvanostatic measurement. The results show that high degree of graphitization can be obtained by the substituted boron atom in the carbon lattice, and boron in the resultant boron-doped graphites mainly exist in the form of boron carbide and boron substituted in the carbon lattice. Both of boron-doped graphites from shot and sponge cokes obtain discharge capacity of 350 mAh g{sup -1} and coulombic efficiency above 90%. Apart from commonly observed discharge plateau for graphite, boron-doped samples in this study also show a small plateau at ca. 0.06 V. This phenomenon can be explained that Li ion stores in the site to be void-like spaces that are produced by ''molecular bridging'' between the edge sites of graphene layer stack with a release of boron atoms substituted at the edge of graphene layer. The effect of the amount of boron dopant and graphitization temperature on the anode performance of boron-doped graphite are also investigated in this paper. (author)

  8. Single-shot magnetic resonance spectroscopic imaging with partial parallel imaging.

    Science.gov (United States)

    Posse, Stefan; Otazo, Ricardo; Tsai, Shang-Yueh; Yoshimoto, Akio Ernesto; Lin, Fa-Hsuan

    2009-03-01

    A magnetic resonance spectroscopic imaging (MRSI) pulse sequence based on proton-echo-planar-spectroscopic-imaging (PEPSI) is introduced that measures two-dimensional metabolite maps in a single excitation. Echo-planar spatial-spectral encoding was combined with interleaved phase encoding and parallel imaging using SENSE to reconstruct absorption mode spectra. The symmetrical k-space trajectory compensates phase errors due to convolution of spatial and spectral encoding. Single-shot MRSI at short TE was evaluated in phantoms and in vivo on a 3-T whole-body scanner equipped with a 12-channel array coil. Four-step interleaved phase encoding and fourfold SENSE acceleration were used to encode a 16 x 16 spatial matrix with a 390-Hz spectral width. Comparison with conventional PEPSI and PEPSI with fourfold SENSE acceleration demonstrated comparable sensitivity per unit time when taking into account g-factor-related noise increases and differences in sampling efficiency. LCModel fitting enabled quantification of inositol, choline, creatine, and N-acetyl-aspartate (NAA) in vivo with concentration values in the ranges measured with conventional PEPSI and SENSE-accelerated PEPSI. Cramer-Rao lower bounds were comparable to those obtained with conventional SENSE-accelerated PEPSI at the same voxel size and measurement time. This single-shot MRSI method is therefore suitable for applications that require high temporal resolution to monitor temporal dynamics or to reduce sensitivity to tissue movement.

  9. Multianalyte imaging in one-shot format sensors for natural waters

    International Nuclear Information System (INIS)

    Lapresta-Fernandez, A.; Huertas, Rafael; Melgosa, Manuel; Capitan-Vallvey, L.F.

    2009-01-01

    A one-shot multisensor based on ionophore-chromoionophore chemistry for optical monitoring of potassium, magnesium and hardness in water is presented. The analytical procedure uses a black and white non-cooled CCD camera for image acquisition of the one-shot multisensor after reaction, followed by data treatment for quantitation using the grey value pixel average from a defined region of interest from each sensing area to build the analytical parameter 1 - α. In optimised experimental conditions, the procedure shows a large linear range, up to 6 orders using the linearised model and good detection limits: 9.92 x 10 -5 mM, 1.86 x 10 -3 mM and 1.30 x 10 -2 mg L -1 of CaCO 3 for potassium, magnesium and hardness, respectively. This analysis system exhibits good precision in terms of relative standard deviation (RSD%) from 2.3 to 3.8 for potassium, from 5.0 to 6.8 for magnesium and from 5.4 to 5.9 for hardness. The trueness of this multisensor procedure was demonstrated comparing it with results obtained by a DAD spectrophotometer used as a reference. Finally, it was satisfactorily applied to the analysis of these analytes in miscellaneous samples, such as water and beverage samples from different origins, validating the results against atomic absorption spectrometry (AAS) as the reference procedure

  10. Experimental results from CEM-UTS single shot 9 mj railgun

    International Nuclear Information System (INIS)

    Hayes, R.J.; Zowarka, R.C.

    1991-01-01

    The Center for Electromechanics at the University of Texas at Austin (CEM-UT) has designed and fabricated a 10-m long 90 mm bore railgun. During the test program, a number of solid armatures and projectile packages have been tested in a 50 m deep vertical test range. The experiments are powered by six homopolar generator (HPG) charged inductive stores, sequentially staged to provide the desired acceleration profile. Prior to testing, computer simulations are run to determine the preferred current profile and predict system performance. During projectile flight, high speed films, x-rays, muzzle volts, and velocity/acceleration profiles are recorded along with power supply operating parameters. Postshot diagnostics include bore wear analysis and armature and target recovery. Comparisons of predicted and recorded shot performance are also made. On selected tests, an energy balance is performed to determine efficiencies of the various system components. In this paper, a summary of all 90 mm gun shots is presented along with critical data collected from selected tests

  11. Gunshot-like wound caused by sling shot injury – a case report

    Directory of Open Access Journals (Sweden)

    Vinuthinee N

    2015-02-01

    Full Text Available Naidu Vinuthinee,1,2 Anuar Azreen-Redzal,1 Jaafar Juanarita,1 Embong Zunaina2 1Department of Ophthalmology, Hospital Sultanah Bahiyah, Alor Setar, Kedah, Malaysia; 2Department of Ophthalmology, School of Medical Sciences, Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia Abstract: We report a rare case of sling shot injury that presented with a gunshot-like wound with preseptal cellulitis, in a toddler. An 11-month-old Malay child presented with a gunshot-like wound over the forehead following sling shot injury. On examination, he had a deep circular laceration wound over the forehead, measuring 2.0 cm in diameter, with minimal bleeding. There was no obvious foreign body seen inside the wound and no palpable foreign body surrounding the wound. The gunshot-like wound was associated with left preseptal cellulitis. A skull X-ray showed a white opaque foreign body in the left frontal bone. Computed tomography (CT scan of orbit and brain revealed a left comminuted fracture of the left orbital roof, and left frontal brain contusion with prelesional edema. Wound exploration was performed and revealed a 0.5 cm unshattered marble embedded in the left frontal bone. The marble and bone fragments were removed. The left preseptal cellulitis responded well to intravenous antibiotic and topical antibiotic. Keywords: preseptal cellulitis, orbital roof fracture, pediatric trauma

  12. Anode performance of boron-doped graphites prepared from shot and sponge cokes

    Science.gov (United States)

    Liu, Tao; Luo, Ruiying; Yoon, Seong-Ho; Mochida, Isao

    The structures and anode performances of graphitized pristine and boron-doped shot and sponge cokes have been comparatively studied by means of scanning electron microscope (SEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and galvanostatic measurement. The results show that high degree of graphitization can be obtained by the substituted boron atom in the carbon lattice, and boron in the resultant boron-doped graphites mainly exist in the form of boron carbide and boron substituted in the carbon lattice. Both of boron-doped graphites from shot and sponge cokes obtain discharge capacity of 350 mAh g -1 and coulombic efficiency above 90%. Apart from commonly observed discharge plateau for graphite, boron-doped samples in this study also show a small plateau at ca. 0.06 V. This phenomenon can be explained that Li ion stores in the site to be void-like spaces that are produced by "molecular bridging" between the edge sites of graphene layer stack with a release of boron atoms substituted at the edge of graphene layer. The effect of the amount of boron dopant and graphitization temperature on the anode performance of boron-doped graphite are also investigated in this paper.

  13. Shot-noise-limited optical Faraday polarimetry with enhanced laser noise cancelling

    International Nuclear Information System (INIS)

    Li, Jiaming; Luo, Le; Carvell, Jeff; Cheng, Ruihua; Lai, Tianshu; Wang, Zixin

    2014-01-01

    We present a shot-noise-limited measurement of optical Faraday rotations with sub-ten-nanoradian angular sensitivity. This extremely high sensitivity is achieved by using electronic laser noise cancelling and phase sensitive detection. Specially, an electronic laser noise canceller with a common mode rejection ratio of over 100 dB was designed and built for enhanced laser noise cancelling. By measuring the Faraday rotation of ambient air, we demonstrate an angular sensitivity of up to 9.0×10 −9  rad/√(Hz), which is limited only by the shot-noise of the photocurrent of the detector. To date, this is the highest angular sensitivity ever reported for Faraday polarimeters in the absence of cavity enhancement. The measured Verdet constant of ambient air, 1.93(3)×10 −9 rad/(G cm) at 633 nm wavelength, agrees extremely well with the earlier experiments using high finesse optical cavities. Further, we demonstrate the applications of this sensitive technique in materials science by measuring the Faraday effect of an ultrathin iron film

  14. Quad shot - hypofractionated radiotherapy for palliation in advanced squamous cell carcinoma of head and neck

    International Nuclear Information System (INIS)

    Maqsood, T.; Ali, U.; Arif, S.

    2017-01-01

    The objective of this study was to determine the efficacy of quad-shot radiation therapy for palliation in locally advanced and metastatic inoperable squamous cell carcinomas of head and neck. Study Design: A quasi-experimental study. Place and Duration of Study: Oncology department, Combined Military Hospital Rawalpindi, from Sep 2012 to Sep 2013. Material and Methods: Thirty five patients were included with histologically confirmed advanced inoperable squamous cell carcinoma in head and neck region, performance status 2 or 3 and survival =3 months. Patients were treated with radiation therapy 14 Gy in four fractions, megavoltage beam, twice daily fractions (at least 6 hours apart), for 2 consecutive days. Symptoms due to cancer (pain and dysphagia) were assessed as per common toxicity criteria adverse event version 4.0 on day 0 before treatment and day 21 after start of treatment. Results: Grades of pain and dysphagia showed significant improvement after treatment with a p-value <0.001. A total of 91.4% patients showed an improvement in grade of pain (32 out of 35 patients) and 45.7% of patients showed improvement in grade of dysphagia (16 out of 35 patients). There was a statistically significant decrease in grades of pain and dysphagia after treatment. Conclusion: The short duration of hypofractionated radiotherapy with Quad Shot was effective with respect to symptom palliation in locally advanced and metastatic inoperable head and neck cancers.

  15. One-Shot Learning of Human Activity With an MAP Adapted GMM and Simplex-HMM.

    Science.gov (United States)

    Rodriguez, Mario; Orrite, Carlos; Medrano, Carlos; Makris, Dimitrios

    2016-05-10

    This paper presents a novel activity class representation using a single sequence for training. The contribution of this representation lays on the ability to train an one-shot learning recognition system, useful in new scenarios where capturing and labeling sequences is expensive or impractical. The method uses a universal background model of local descriptors obtained from source databases available on-line and adapts it to a new sequence in the target scenario through a maximum a posteriori adaptation. Each activity sample is encoded in a sequence of normalized bag of features and modeled by a new hidden Markov model formulation, where the expectation-maximization algorithm for training is modified to deal with observations consisting in vectors in a unit simplex. Extensive experiments in recognition have been performed using one-shot learning over the public datasets Weizmann, KTH, and IXMAS. These experiments demonstrate the discriminative properties of the representation and the validity of application in recognition systems, achieving state-of-the-art results.

  16. Eight-shot pellet injector and fueling experiments at the HL-1M tokamak

    International Nuclear Information System (INIS)

    Xiao Zhenggui; Li Bo; Li Li

    2001-01-01

    An Eight-shot Pellet Injection (EPI) system has been proposed and developed in collaboration between STU (St. Petersburg State Technical University) of Russia and SWIP. In the EPI, the I n-situ c ondensation technique was used to produce the pellets in eight gun barrels respectively. The nominal pellet size (diameter of 1.0 mm and of 1.4 mm or 1.2 mm) is limited by the gun barrel inner diameter. The pellet length is adjusted by changing the g radient temperature o n the gun barrels and the amounts of filling fuel gas. Pellets are fired at speed range of 200 - 1200 m/s by He propellant with pressure of 2 - 6 MPa and then transferred to HL-1M vessel through an injection line that consists of two set of differential vacuum pumped chambers and guide tube combined with fast valves. In addition, this unit is equipped with diagnostics for pellet velocity and shape measure. The EPI has installed on HL-1M since 1996 for the multi-shot pellet fueling experiments. The typical characteristics including the peaked density profile and improved confinement, the deep penetration and suppression of soft X-ray sawteeth, the variance of rotation and flow of plasma in edge region as well as the photographing of pellet ablation clouds are presented

  17. D2 and DT Liquid-Layer Target Shots on NIF

    Energy Technology Data Exchange (ETDEWEB)

    Walters, Curtis [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Alger, Ethan [General Atomics, San Diego, CA (United States); Bhandarkar, Suhas [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Boehm, Kurt [General Atomics, San Diego, CA (United States); Braun, Tom [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Espinosaloza, Francisco [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Haid, Benjamin [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Heredia, Ricardo [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kline, John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Kozioziemski, Bernard [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kroll, Jeremy [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Malone, Daniel [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Nikroo, Abbas [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Opsahl, Patrick [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Sater, James [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Zylstra, Alex [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-22

    Experiments at the National Ignition Facility (NIF) using targets containing a Deuterium-Tritium (DT) fuel layer have, until recently, required that a high-quality layer of solid deuterium-tritium (herein referred to as an "ice-layer") be formed in the capsule. The development of a process to line the inner surface of a target capsule with a foam layer of a thickness that is typical of icelayers has resulted in the ability to field targets with liquid layers wetting the foam. Successful fielding of liquid-layer targets on NIF required not only a foam lined capsule, but also changes to the capsule filling process and the manner with which the inventory is maintained in the capsule. Additionally, changes to target heater power and the temperature drops across target components were required in order to achieve the desired range of shot temperatures. These changes, and the target's performance during four target shots on NIF will be discussed.

  18. Single shot trajectory design for region-specific imaging using linear and nonlinear magnetic encoding fields.

    Science.gov (United States)

    Layton, Kelvin J; Gallichan, Daniel; Testud, Frederik; Cocosco, Chris A; Welz, Anna M; Barmet, Christoph; Pruessmann, Klaas P; Hennig, Jürgen; Zaitsev, Maxim

    2013-09-01

    It has recently been demonstrated that nonlinear encoding fields result in a spatially varying resolution. This work develops an automated procedure to design single-shot trajectories that create a local resolution improvement in a region of interest. The technique is based on the design of optimized local k-space trajectories and can be applied to arbitrary hardware configurations that employ any number of linear and nonlinear encoding fields. The trajectories designed in this work are tested with the currently available hardware setup consisting of three standard linear gradients and two quadrupolar encoding fields generated from a custom-built gradient insert. A field camera is used to measure the actual encoding trajectories up to third-order terms, enabling accurate reconstructions of these demanding single-shot trajectories, although the eddy current and concomitant field terms of the gradient insert have not been completely characterized. The local resolution improvement is demonstrated in phantom and in vivo experiments. Copyright © 2012 Wiley Periodicals, Inc.

  19. Do individual differences in use of cover habitat affect red deer`s (Cervus elaphus) probability of being shot by hunters?

    OpenAIRE

    Stamnes, Inga

    2014-01-01

    The purpose of this study was to test if red deer (Cervus elaphus) habitat use affects their risk of being shot by hunters. I compared habitat use of 20 GPS-marked red deer that survived the hunting season with 20 individuals that were shot. I predicted that shot red deer used open areas within forested habitats with a better visibility for hunters than surviving red deer. I also predicted that the use of less risky habitat is costly in terms of foraging opportunity, with shot animals using b...

  20. A preliminary investigation regarding the effect of tennis grunting: does white noise during a tennis shot have a negative impact on shot perception?

    Science.gov (United States)

    Sinnett, Scott; Kingstone, Alan

    2010-10-01

    There is a growing chorus of critics who complain that many of the top-ranked professional tennis players who grunt when they hit the ball gain an unfair advantage because the sound of the grunt interferes with their opponent's game. However, there is no scientific evidence to support this claim. We explored this potential detrimental effect of grunting by presenting videos of a tennis player hitting a ball to either side of a tennis court; the shot either did, or did not, contain a brief sound that occurred at the same time as contact. The participants' task was to respond as quickly as possible, indicating whether the ball was being hit to the left- or right-side of the court. The results were unequivocal: The presence of an extraneous sound interfered with a participants' performance, making their responses both slower and less accurate. Our data suggest that a grunting player has a competitive edge on the professional tennis tour. The mechanism that underlies this effect is a topic for future investigation. Viable alternatives are discussed. For example, the possibility that the interfering auditory stimulus masks the sound of the ball being struck by the racket or it distracts an opponent's attention away from the sound of the ball.

  1. A preliminary investigation regarding the effect of tennis grunting: does white noise during a tennis shot have a negative impact on shot perception?

    Directory of Open Access Journals (Sweden)

    Scott Sinnett

    Full Text Available BACKGROUND: There is a growing chorus of critics who complain that many of the top-ranked professional tennis players who grunt when they hit the ball gain an unfair advantage because the sound of the grunt interferes with their opponent's game. However, there is no scientific evidence to support this claim. METHODOLOGY/PRINCIPAL FINDINGS: We explored this potential detrimental effect of grunting by presenting videos of a tennis player hitting a ball to either side of a tennis court; the shot either did, or did not, contain a brief sound that occurred at the same time as contact. The participants' task was to respond as quickly as possible, indicating whether the ball was being hit to the left- or right-side of the court. The results were unequivocal: The presence of an extraneous sound interfered with a participants' performance, making their responses both slower and less accurate. CONCLUSIONS/SIGNIFICANCE: Our data suggest that a grunting player has a competitive edge on the professional tennis tour. The mechanism that underlies this effect is a topic for future investigation. Viable alternatives are discussed. For example, the possibility that the interfering auditory stimulus masks the sound of the ball being struck by the racket or it distracts an opponent's attention away from the sound of the ball.

  2. THE EFFECT OF THE CONDITIONS OF SHOT PEENING THE INCONEL 718 NICKEL ALLOY ON THE GEOMETRICAL STRUCTURE OF THE SURFACE

    Directory of Open Access Journals (Sweden)

    Kazimierz Zaleski

    2017-06-01

    Full Text Available The article presents the research results of roughness and topography of the surface of Inconel 718 nickel alloy after shot peening. Evaluation of stereometric properties of the surface layer of the examined material was performed based on the amplitude, height and Abbott-Firestone curve parametres. The shot peening was carried out on the impulse shot peening stand. The impact energy Ej, distance between the traces xs and the ball diameter dk were changed in the range: Ej = 60 ÷ 240 mJ, xs = 0,15 ÷ 0,5 mm, dk = 3,95 ÷ 12,45 mm. The T8000 RC 120-140 device of the Hommel-Etamic company, along with the software, was used for measuring the surface roughness and for determining the material bearing curve. As a result of the machin-ing, the surface roughness was reduced and the selected functional parameters were improved.

  3. Effect of shot peening treatment in the behavior of residual stress in duplex stainless steel during medium cycle fatigue

    International Nuclear Information System (INIS)

    Pedrosa, Peter D.S.; Rebello, Joao Marcos A.; Fonseca, Maria P. Cindra

    2010-01-01

    The lifetime of duplex stainless steel parts experiencing cyclic fatigue is directly influenced by the residual stresses present in the ferrite and austenite phases. The motivation for this work was to analyze the behaviour of the residual stresses fields introduced by shot peening treatment in both phases, in the sample surface as in the subsurface layers, in low fatigue cycles, using the X-rays diffraction technique. The results shows that the compressive residual stresses introduced by the shot peening treatment in both phases improved fatigue life of the material. However, the cyclical loads produce partial or total relief in these residual stresses fields. It was verified that the shot peening process induced the formation of microcracks only in the ferrite phase. The largest variations in the total compressive residual stresses fields also occurred in this phase. The samples surfaces were analyzed by scanning electron microscopy. (author)

  4. On the Path to SunShot: Emerging Issues and Challenges in Integrating Solar with the Distribution System.

    Energy Technology Data Exchange (ETDEWEB)

    Broderick, Robert Joseph [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Palmintier, Bryan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Mather, Bary [National Renewable Energy Lab. (NREL), Golden, CO (United States); Coddington, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States); Baker, Kyri [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ding, Fei [National Renewable Energy Lab. (NREL), Golden, CO (United States); Reno, Matthew J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lave, Matthew Samuel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bharatkumar, Ashwini [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2016-03-01

    The U.S. Department of Energy launched the SunShot Initiative in 2011 with the goal of making solar electricity cost-competitive with conventionally generated electricity by 2020. At the time this meant reducing photovoltaic and concentrating solar power prices by approximately 75%— relative to 2010 costs—across the residential, commercial, and utility-scale sectors. To examine the implications of this ambitious goal, the Department of Energy’s Solar Energy Technologies Office (SETO) published the SunShot Vision Study in 2012. The study projected that achieving the SunShot price-reduction targets could result in solar meeting roughly 14% of U.S. electricity demand by 2030 and 27% by 2050—while reducing fossil fuel use, cutting emissions of greenhouse gases and other pollutants, creating solar-related jobs, and lowering consumer electricity bills.

  5. Magnetic Resonance Cholangiopancreatography: Image Quality, Ductal Morphology, and Value of Additional T2- and T1-weighted Sequences for the Assessment of Suspected Pancreatic Cancer

    International Nuclear Information System (INIS)

    Lopez Haenninen, E.; Ricke, H.; Amthauer, H.; Roettgen, R.; Boehmig, M.; Langrehr, J.; Pech, M.; Denecke, T.; Rosewicz, S.; Felix, R.

    2005-01-01

    Purpose: To assess image quality and duct morphology on magnetic resonance cholangiopancreatography (MRCP) and also the value of additional T2- and T1-weighted sequences for differentiation of benignity and malignancy in patients with suspected pancreatic tumors. Material and Methods: One-hundred-and-fourteen patients received MRCP and unenhanced and contrast material-enhanced MR imaging. MR results were analyzed independently by two blinded readers, and subsequently correlated with the results from surgery, biopsy, and follow-up. Assessment included the evaluation of image quality, duct visualization and morphology, and the differentiation of pancreatic lesion status (benign versus malignant).Results: Overall, 49 patients had benign final diagnoses, while 65 had a malignant diagnosis. Image quality of single-shot thick-slab MRCP was rated significantly better than the MIP images of multisection MRCP. With MRCP alone, the two readers' accuracy in the assessment of pancreatic lesion status was 72% (95% CI, 64% to 83%) and 69% (95% CI, 56% to 77%), respectively; with the addition of T2- and T1-weighted images the accuracy significantly improved to 89% (95% CI, 82% to 95%) and 84% (95% CI, 77% to 92%) for readers 1 and 2, respectively. Conclusion: Single-shot thick-slab MRCP and multisection MRCP provide complementary results; however, single-shot MRCP had superior image quality. Moreover, assessment of ductal morphology with MRCP alone facilitated the diagnosis of different pathologic conditions of the pancreatobiliary system in the majority of patients. However, with the addition of T2- and T1-weighted sequences the overall diagnostic accuracy was significantly improved and thus we consider that a comprehensive MR approach should comprise both MRCP techniques and parenchymal sequences

  6. Comparison of caffeine disposition following administration by oral solution (energy drink) and inspired powder (AeroShot) in human subjects.

    Science.gov (United States)

    Laizure, S Casey; Meibohm, Bernd; Nelson, Kembral; Chen, Feng; Hu, Zhe-Yi; Parker, Robert B

    2017-12-01

    To determine the disposition and effects of caffeine after administration using a new dosage form (AeroShot) that delivers caffeine by inspiration of a fine powder into the oral cavity and compare it to an equivalent dose of an oral solution (energy drink) as the reference standard. Healthy human subjects (n = 17) inspired a 100 mg caffeine dose using the AeroShot device or consumed an energy drink on separate study days. Heart rate, blood pressure and subject assessments of effects were measured over an 8-h period. Plasma concentrations of caffeine and its major metabolites were determined by liquid chromatography-mass spectrometry. Pharmacokinetic, cardiovascular and perceived stimulant effects were compared between AeroShot and energy drink phases using a paired t test and standard bioequivalency analysis. Caffeine disposition was similar after caffeine administration by the AeroShot device and energy drink: peak plasma concentration 1790 and 1939 ng ml -1 , and area under the concentration-time curve (AUC) 15 579 and 17 569 ng ml -1 × h, respectively, but they were not bioequivalent: AeroShot AUC of 80.3% (confidence interval 71.2-104.7%) and peak plasma concentration of 86.3% (confidence interval 62.8-102.8%) compared to the energy drink. Female subjects did have a significantly larger AUC compared to males after consumption of the energy drink. The heart rate and blood pressure were not significantly affected by the 100 mg caffeine dose, and there were no consistently perceived stimulant effects by the subjects using visual analogue scales. Inspiration of caffeine as a fine powder using the AeroShot device produces a similar caffeine profile and effects compared to administration of an oral solution (energy drink). © 2017 The British Pharmacological Society.

  7. On superactivation of one-shot quantum zero-error capacity and the related property of quantum measurements

    DEFF Research Database (Denmark)

    Shirokov, M. E.; Shulman, Tatiana

    2014-01-01

    We give a detailed description of a low-dimensional quantum channel (input dimension 4, Choi rank 3) demonstrating the symmetric form of superactivation of one-shot quantum zero-error capacity. This property means appearance of a noiseless (perfectly reversible) subchannel in the tensor square...... of a channel having no noiseless subchannels. Then we describe a quantum channel with an arbitrary given level of symmetric superactivation (including the infinite value). We also show that superactivation of one-shot quantum zero-error capacity of a channel can be reformulated in terms of quantum measurement...

  8. Residual stress relaxation due to fretting fatigue in shot peened surfaces of Ti-6Al-4V

    International Nuclear Information System (INIS)

    Martinez, S.A.; Blodgett, M.P.; Mall, S.; Sathish, S.; Namjoshi, S.

    2003-01-01

    Fretting fatigue occurs at locations where the materials are sliding against each other under load. In order to enhance the fatigue life under fretting conditions the surface of the component is shot peened. In general, the shot peening process produces a compressive stress on the surface of the material, thereby increasing the resistance of the material to crack initiation. This paper presents the relaxation of residual stress caused during fretting fatigue. X-ray diffraction has been utilized as the method to measure residual stress in fretting fatigued samples of Ti-6Al-4V

  9. The role of biomechanics in maximising distance and accuracy of golf shots.

    Science.gov (United States)

    Hume, Patria A; Keogh, Justin; Reid, Duncan

    2005-01-01

    Golf biomechanics applies the principles and technique of mechanics to the structure and function of the golfer in an effort to improve golf technique and performance. A common recommendation for technical correction is maintaining a single fixed centre hub of rotation with a two-lever one-hinge moment arm to impart force on the ball. The primary and secondary spinal angles are important for conservation of angular momentum using the kinetic link principle to generate high club-head velocity. When the golfer wants to maximise the distance of their drives, relatively large ground reaction forces (GRF) need to be produced. However, during the backswing, a greater proportion of the GRF will be observed on the back foot, with transfer of the GRF on to the front foot during the downswing/acceleration phase. Rapidly stretching hip, trunk and upper limb muscles during the backswing, maximising the X-factor early in the downswing, and uncocking the wrists when the lead arm is about 30 degrees below the horizontal will take advantage of the summation of force principle. This will help generate large angular velocity of the club head, and ultimately ball displacement. Physical conditioning will help to recruit the muscles in the correct sequence and to optimum effect. To maximise the accuracy of chipping and putting shots, the golfer should produce a lower grip on the club and a slower/shorter backswing. Consistent patterns of shoulder and wrist movements and temporal patterning result in successful chip shots. Qualitative and quantitative methods are used to biomechanically assess golf techniques. Two- and three-dimensional videography, force plate analysis and electromyography techniques have been employed. The common golf biomechanics principles necessary to understand golf technique are stability, Newton's laws of motion (inertia, acceleration, action reaction), lever arms, conservation of angular momentum, projectiles, the kinetic link principle and the stretch

  10. Optimization And Single-Shot Characterization Of Ultrashort Thz Pulses From A Laser Wakefield Accelerator

    International Nuclear Information System (INIS)

    Plateau, G.R.; Matlis, N.H.; van Tilborg, J.; Geddes, C.G.R.; Toth, Cs.; Schroeder, C.B.; Leemans, W.P.

    2009-01-01

    We present spatiotemporal characterization of μJ-class ultrashort THz pulses generated from a laser wakefield accelerator (LWFA). Accelerated electrons, resulting from the interaction of a high-intensity laser pulse with a plasma, emit high-intensity THz pulses as coherent transition radiation. Such high peak-power THz pulses, suitable for high-field (MV/cm) pump-probe experiments, also provide a non-invasive bunch-length diagnostic and thus feedback for the accelerator. The characterization of the THz pulses includes energy measurement using a Golay cell, 2D sign-resolved electro-optic measurement and single-shot spatiotemporal electric-field distribution retrieval using a new technique, coined temporal electric-field cross-Correlation (TEX). All three techniques corroborate THz pulses of ∼ 5 μJ, with peak fields of 100's of kV/cm and ∼ 0.4 ps rms duration.

  11. Single-Shot Quantum Nondemolition Detection of Individual Itinerant Microwave Photons

    Science.gov (United States)

    Besse, Jean-Claude; Gasparinetti, Simone; Collodo, Michele C.; Walter, Theo; Kurpiers, Philipp; Pechal, Marek; Eichler, Christopher; Wallraff, Andreas

    2018-04-01

    Single-photon detection is an essential component in many experiments in quantum optics, but it remains challenging in the microwave domain. We realize a quantum nondemolition detector for propagating microwave photons and characterize its performance using a single-photon source. To this aim, we implement a cavity-assisted conditional phase gate between the incoming photon and a superconducting artificial atom. By reading out the state of this atom in a single shot, we reach an external (internal) photon-detection fidelity of 50% (71%), limited by transmission efficiency between the source and the detector (75%) and the coherence properties of the qubit. By characterizing the coherence and average number of photons in the field reflected off the detector, we demonstrate its quantum nondemolition nature. We envisage applications in generating heralded remote entanglement between qubits and for realizing logic gates between propagating microwave photons.

  12. Single-shot parallel full range complex Fourier-domain optical coherence tomography

    International Nuclear Information System (INIS)

    Huang Bingjie; Bu Peng; Nan Nan; Wang Xiangzhao

    2011-01-01

    We present a method of parallel full range complex Fourier-domain optical coherence tomography (FDOCT) that is capable of acquiring an artifacts-free two-dimensional (2-D) cross-sectional image, i.e. a full range B-scan tomogram, by a single shot of 2-D CCD camera. This method is based on a spatial carrier technique, in which the spatial carrier-frequency is instantaneously introduced into the 2-D spectral interferogram registered in parallel FDOCT by using a grating-generated reference beam. The spatial-carrier-contained 2-D spectral interferogram is processed through Fourier transformation to obtain a complex 2-D spectral interferogram. From the 2-D complex spectral interferomgram, a full range B-scan tomogram is reconstructed. The principle of our method is confirmed by imaging an onion sample.

  13. One-Shot Decoupling and Page Curves from a Dynamical Model for Black Hole Evaporation.

    Science.gov (United States)

    Brádler, Kamil; Adami, Christoph

    2016-03-11

    One-shot decoupling is a powerful primitive in quantum information theory and was hypothesized to play a role in the black hole information paradox. We study black hole dynamics modeled by a trilinear Hamiltonian whose semiclassical limit gives rise to Hawking radiation. An explicit numerical calculation of the discretized path integral of the S matrix shows that decoupling is exact in the continuous limit, implying that quantum information is perfectly transferred from the black hole to radiation. A striking consequence of decoupling is the emergence of an output radiation entropy profile that follows Page's prediction. We argue that information transfer and the emergence of Page curves is a robust feature of any multilinear interaction Hamiltonian with a bounded spectrum.

  14. Surface topography of cylindrical gear wheels after smoothing in abrasive mass, honing and shot peening

    International Nuclear Information System (INIS)

    Michalski, J; Pawlus, P; Zelasko, W

    2011-01-01

    The present paper presents the analysis of surface topography of gear teeth as the result of final machining processes. Teeth of multiple cylindrical gears shaped by grinding were smoothed in abrasive mass, honed or shot peened. The measurement of gears were made using coordinate measuring machine and 3D surface topography stylus instrument. The following deviations were studied; pitch deviation, total pitches deviations, variation of teeth thickness and deviation of gear radial run-out. Changes in teeth surface topography during machining process were determined. 3D surface topography parameters, surface directionality as well as areal autocorrelation and power spectral density functions were taken into consideration. As the results of the analysis, the best surface topography with regard to gear operational properties was recommended.

  15. Evaluation of shot peened surfaces using characterization technique of three-dimensional surface topography

    International Nuclear Information System (INIS)

    Kurokawa, S; Ariura, Y

    2005-01-01

    Objective parameters to characterize global topography of three-dimensional surfaces have been derived. The idea of this evaluation is to separate the topography into two global form deviations and residual ones according to the degree of curved surfaces. A shot peened Almen strip is measured by profilometer and concrete parameters of inclination and circular-arc shaped global topography are extracted using the characterization technique. The arc height is calculated using the circular arc-shaped part and compared with a value measured by an Almen gauge. The relation between the coverage and roughness parameters is also investigated. The advantage of this evaluation is that it is possible to determine the arc height and the coverage at the same time from single measured topography. In addition, human error can be excluded from measurement results. This method has the wide application in the field of measurement

  16. Single-shot and single-spot measurement of laser ablation threshold for carbon nanotubes

    International Nuclear Information System (INIS)

    Lednev, Vasily N; Pershin, Sergey M; Bunkin, Alexey F; Obraztsova, Elena D; Kudryashov, Sergey I

    2013-01-01

    A simple and convenient procedure for single-shot, single-spot ablation threshold measurement is developed. It is based on the employment of cylindrical lens to obtain an elliptical Gaussian laser spot. The ablated spot chords that are parallel to the minor axis are measured across the spot major axis, which is proportional to the fluence cross-section, thus providing wide range dependence of damaged spot size versus fluence in one spot measurement. For both conventional and newly developed procedures the ablation threshold for typical Nd:YAG laser parameters (1064 nm, 10 ns) is measured as 50 ± 5 mJ cm -2 , which is one order of magnitude lower than that for bulk graphite.

  17. Contact doping, Klein tunneling, and asymmetry of shot noise in suspended graphene

    Science.gov (United States)

    Laitinen, Antti; Paraoanu, G. S.; Oksanen, Mika; Craciun, Monica F.; Russo, Saverio; Sonin, Edouard; Hakonen, Pertti

    2016-01-01

    The inherent asymmetry of the electric transport in graphene is attributed to Klein tunneling across barriers defined by p n interfaces between positively and negatively charged regions. By combining conductance and shot noise experiments, we determine the main characteristics of the tunneling barrier (height and slope) in a high-quality suspended sample with Au/Cr/Au contacts. We observe an asymmetric resistance Rodd=100 -70 Ω across the Dirac point of the suspended graphene at carrier density | nG|=(0.3 -4 ) × 1011cm-2 , while the Fano factor displays a nonmonotonic asymmetry in the range Fodd˜0.03 -0.1. Our findings agree with analytical calculations based on the Dirac equation with a trapezoidal barrier. Comparison between the model and the data yields the barrier height for tunneling, an estimate of the thickness of the p n interface d graphene.

  18. [Pediatric orbital emphysema caused by a compressed-air pistol shot: a case report].

    Science.gov (United States)

    Navarro-Mingorance, A; Reyes-Dominguez, S B; León-León, M C

    2014-09-01

    We report the case of a 2 year-old child with orbital emphysema secondary to a compressed-air gun shot in the malar region, with no evidence of orbital wall fracture. Conservative treatment was applied, and no complications were observed. Orbital emphysema in the absence of an orbital wall fracture is a rare situation. Orbital emphysema is usually seen in facial trauma associated with damage to the adjacent paranasal sinuses or facial bones. To our knowledge there have been very few reports of orbital emphysema caused by a compressed-air injury. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  19. DebrisLV Hypervelocity Impact Post-Shot Physical Results Summary

    Science.gov (United States)

    2015-02-27

    simulaFng  a  solar-­‐panel   •  15  MJoules  energy   •  6061-T6 Frame •  Nylon Body •  Hollow Center for Electronics BODY...model  results  to  predict   plasm  jet  formaOon  in  relaOvely  simple  structures.    More  modeling  needs  to...Post-­‐Shot  Materials  Physics  Results,”   TOR-­‐2014-­‐03192   Approved Electronically by: Technical Peer Review Performed by

  20. Kinematic MRI using short TR single shot fast spin echo (SSFSE) in evaluating swallowing

    Energy Technology Data Exchange (ETDEWEB)

    Isogai, Satoshi; Takehara, Yasuo; Isoda, Haruo; Kodaira, Nami; Masunaga, Hatsuko; Ozawa, Fukujirou; Kaneko, Masao [Hamamatsu Univ. School of Medicine, Shizuoka (Japan); Nozaki, Atsushi; Kabasawa, Hiroyuki

    1999-03-01

    The utility of short TR single shot fast spin echo (SSFSE) MR imaging for evaluating swallowing was determined. Five healthy volunteers underwent kinematic MR imaging of swallowing with a 1.5 T MR scanner using the short TR (300 ms) SSFSE sequence. Twenty phases of sagittal sections were acquired within 6 sec, where the temporal resolution was 300 ms. For oral contrast medium, we used prune yogurt juice with Fe added. The image contrast of short TR SSFSE was found to be somewhere like that of T1-weighted images. In all cases, both the buccal and pharyngeal stages of swallowing were successfully depicted. The Fe-added prune yogurt juice performed as a positive contrast medium and helped determine anatomical structures in the buccal stage. Short TR (300 ms) SSFSE was useful in evaluating swallowing. The combined use of Fe-added prune yogurt juice was helpful in enhancing the surface of the oropharynx. (author)

  1. Kinematic MRI using short TR single shot fast spin echo (SSFSE) in evaluating swallowing

    International Nuclear Information System (INIS)

    Isogai, Satoshi; Takehara, Yasuo; Isoda, Haruo; Kodaira, Nami; Masunaga, Hatsuko; Ozawa, Fukujirou; Kaneko, Masao; Nozaki, Atsushi; Kabasawa, Hiroyuki

    1999-01-01

    The utility of short TR single shot fast spin echo (SSFSE) MR imaging for evaluating swallowing was determined. Five healthy volunteers underwent kinematic MR imaging of swallowing with a 1.5 T MR scanner using the short TR (300 ms) SSFSE sequence. Twenty phases of sagittal sections were acquired within 6 sec, where the temporal resolution was 300 ms. For oral contrast medium, we used prune yogurt juice with Fe added. The image contrast of short TR SSFSE was found to be somewhere like that of T1-weighted images. In all cases, both the buccal and pharyngeal stages of swallowing were successfully depicted. The Fe-added prune yogurt juice performed as a positive contrast medium and helped determine anatomical structures in the buccal stage. Short TR (300 ms) SSFSE was useful in evaluating swallowing. The combined use of Fe-added prune yogurt juice was helpful in enhancing the surface of the oropharynx. (author)

  2. Fast Detection of Airports on Remote Sensing Images with Single Shot MultiBox Detector

    Science.gov (United States)

    Xia, Fei; Li, HuiZhou

    2018-01-01

    This paper introduces a method for fast airport detection on remote sensing images (RSIs) using Single Shot MultiBox Detector (SSD). To our knowledge, this could be the first study which introduces an end-to-end detection model into airport detection on RSIs. Based on the common low-level features between natural images and RSIs, a convolution neural network trained on large amounts of natural images was transferred to tackle the airport detection problem with limited annotated data. To deal with the specific characteristics of RSIs, some related parameters in the SSD, such as the scales and layers, were modified for more accurate and rapider detection. The experiments show that the proposed method could achieve 83.5% Average Recall at 8 FPS on RSIs with the size of 1024*1024. In contrast to Faster R-CNN, an improvement on AP and speed could be obtained.

  3. An Eye-tracking Study of Feature-based Choice in One-shot Games

    DEFF Research Database (Denmark)

    Devetag, Giovanna; Di Guida, Sibilla; Polonio, Luca

    2016-01-01

    for a subset of game outcomes. We analyze subjects’ eye movements while playing a series of two-person, 3x3 one-shot games in normal form. Games within each class differ by a set of descriptive features (i.e., features that can be changed without altering the game equilibrium properties). Data show......Previous experimental research suggests that individuals apply rules of thumb to a simplified mental model of the "real" decision problem. We claim that this simplification is obtained either by neglecting the other players' incentives and beliefs or by taking them into consideration only...... that subjects on average perform partial or non-strategic analysis of the payoff matrix, often ignoring the opponent´s payoffs and rarely performing the necessary steps to detect dominance. Our analysis of eye-movements supports the hypothesis that subjects use simple decision rules such as "choose the strategy...

  4. Compressive sensing sectional imaging for single-shot in-line self-interference incoherent holography

    Science.gov (United States)

    Weng, Jiawen; Clark, David C.; Kim, Myung K.

    2016-05-01

    A numerical reconstruction method based on compressive sensing (CS) for self-interference incoherent digital holography (SIDH) is proposed to achieve sectional imaging by single-shot in-line self-interference incoherent hologram. The sensing operator is built up based on the physical mechanism of SIDH according to CS theory, and a recovery algorithm is employed for image restoration. Numerical simulation and experimental studies employing LEDs as discrete point-sources and resolution targets as extended sources are performed to demonstrate the feasibility and validity of the method. The intensity distribution and the axial resolution along the propagation direction of SIDH by angular spectrum method (ASM) and by CS are discussed. The analysis result shows that compared to ASM the reconstruction by CS can improve the axial resolution of SIDH, and achieve sectional imaging. The proposed method may be useful to 3D analysis of dynamic systems.

  5. Method for single-shot measurement of picosecond laser pulse-lengths without electronic time dispersion

    International Nuclear Information System (INIS)

    Kyrala, G.A.

    1987-01-01

    A two-source shear pattern recording is proposed as a method for single-shot measurement of the pulse shape from nearly monochromatic sources whose pulse lengths are shorter than their coherence times. The basis of this method relies on the assertion that if two identical electromagnetic pulses are recombined with a time delay greater than the sum of their pulse widths, the recordable spatial pattern has no fringes in it. At an arbitrary delay, translated into an actual spatial recording position, the recorded modulated intensity will sample the corresponding laser intensity at that delay time, but with a modulation due to the coherence function of the electromagnetic pulse. Two arrangements are proposed for recording the pattern. The principles, the design parameters, and the methodologies of these arrangements are presented. Resolutions of the configurations and their limitations are given as well

  6. Development of a single-shot-imaging thin film for an online Thomson parabola spectrometer

    International Nuclear Information System (INIS)

    Sakaki, H.; Fukuda, Y.; Nishiuchi, M.; Hori, T.; Yogo, A.; Jinno, S.; Kanasaki, M.; Niita, K.

    2013-01-01

    A single-shot-imaging thin scintillator film was developed for an online Thomson parabola (TP) spectrometer and the first analysis of laser accelerated ions, using the online TP spectrometer, was demonstrated at the JAEA-Kansai Advanced Relativistic Engineering Laser System (J-KAREN). An energy spectrum of ∼4.0 MeV protons is obtained using only this imaging film without the need of a microchannel plate that is typically utilized in online ion analyses. A general-purpose Monte Carlo particle and heavy ion-transport code system, which consists of various quantum dynamics models, was used for the prediction of the luminescent properties of the scintillator. The simulation can reasonably predict not only the ion trajectories detected by the spectrometer, but also luminescence properties.

  7. Transport, shot noise, and topology in AC-driven dimer arrays

    Science.gov (United States)

    Niklas, Michael; Benito, Mónica; Kohler, Sigmund; Platero, Gloria

    2016-11-01

    We analyze an AC-driven dimer chain connected to a strongly biased electron source and drain. It turns out that the resulting transport exhibits fingerprints of topology. They are particularly visible in the driving-induced current suppression and the Fano factor. Thus, shot noise measurements provide a topological phase diagram as a function of the driving parameters. The observed phenomena can be explained physically by a mapping to an effective time-independent Hamiltonian and the emergence of edge states. Moreover, by considering quantum dissipation, we determine the requirements for the coherence properties in a possible experimental realization. For the computation of the zero-frequency noise, we develop an efficient method based on matrix-continued fractions.

  8. Single-shot electro-optic experiments for electron bunch diagnostics at Tsinghua Accelerator Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Wei; Du, Yingchao; Yan, Lixin; Hua, Jianfei; Zhang, Zhen; Zhou, Zheng [Accelerator Laboratory, Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education, Beijing 100084 (China); Huang, Wenhui, E-mail: huangwh@mail.tsinghua.edu.cn [Accelerator Laboratory, Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education, Beijing 100084 (China); Tang, Chuanxiang [Accelerator Laboratory, Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education, Beijing 100084 (China); Li, Ming [Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900 (China)

    2016-10-21

    The electro-optic (EO) technique detects the Coulomb electric field distribution of relativistic electron bunches to obtain the associated longitudinal profile. This diagnostic method allows the direct time-resolved single-shot measurement and thus the real-time monitoring of the bunch profile and beam arrival time in a non-destructive way with sub-picosecond temporal resolution. In this paper, we report the measurement of the longitudinal profile of an electron bunch through electro-optic spectral decoding detection, in which the bunch profile is encoded into the spectra of the linearly chirped laser pulse. The experimental setup and measurement results of a 40 MeV electron bunch are presented, with a temporal profile length of 527 fs rms (~1.24 ps FWHM) and a beam arrival time jitter of 471 fs rms. Temporal resolution and future experimental improvement are also discussed.

  9. Super-Poissonian Shot Noise of Squeezed-Magnon Mediated Spin Transport.

    Science.gov (United States)

    Kamra, Akashdeep; Belzig, Wolfgang

    2016-04-08

    The magnetization of a ferromagnet (F) driven out of equilibrium injects pure spin current into an adjacent conductor (N). Such F|N bilayers have become basic building blocks in a wide variety of spin-based devices. We evaluate the shot noise of the spin current traversing the F|N interface when F is subjected to a coherent microwave drive. We find that the noise spectrum is frequency independent up to the drive frequency, and increases linearly with frequency thereafter. The low frequency noise indicates super-Poissonian spin transfer, which results from quasiparticles with effective spin ℏ^{*}=ℏ(1+δ). For typical ferromagnetic thin films, δ∼1 is related to the dipolar interaction-mediated squeezing of F eigenmodes.

  10. 3 ns single-shot read-out in a quantum dot-based memory structure

    International Nuclear Information System (INIS)

    Nowozin, T.; Bimberg, D.; Beckel, A.; Lorke, A.; Geller, M.

    2014-01-01

    Fast read-out of two to six charges per dot from the ground and first excited state in a quantum dot (QD)-based memory is demonstrated using a two-dimensional electron gas. Single-shot measurements on modulation-doped field-effect transistor structures with embedded InAs/GaAs QDs show read-out times as short as 3 ns. At low temperature (T = 4.2 K) this read-out time is still limited by the parasitics of the setup and the device structure. Faster read-out times and a larger read-out signal are expected for an improved setup and device structure

  11. Hyperspectral interferometry for single-shot absolute measurement of 3-D shape and displacement fields

    Directory of Open Access Journals (Sweden)

    Ruiz P. D.

    2010-06-01

    Full Text Available We propose a method that we call Hyperspectral Interferometry (HSI to resolve the 2π phase unwrapping problem in the analysis of interferograms recorded with a narrow-band light source. By using a broad-band light source and hyperspectral imaging system, a set of interferograms at different wavenumbers are recorded simultaneously on a high resolution image sensor. These are then assembled to form a three-dimensional intensity distribution. By Fourier transformation along the wavenumber axis, an absolute optical path difference is obtained for each pixel independently of the other pixels in the field of view. As a result, interferograms with spatially distinct regions are analysed as easily as continuous ones. The approach is illustrated with a HSI system to measure 3-D profiles of optically smooth or rough surfaces. Compared to existing profilometers able to measure absolute path differences, the single shot nature of the approach provides greater immunity from environmental disturbance.

  12. Single-shot quantitative phase microscopy with color-multiplexed differential phase contrast (cDPC.

    Directory of Open Access Journals (Sweden)

    Zachary F Phillips

    Full Text Available We present a new technique for quantitative phase and amplitude microscopy from a single color image with coded illumination. Our system consists of a commercial brightfield microscope with one hardware modification-an inexpensive 3D printed condenser insert. The method, color-multiplexed Differential Phase Contrast (cDPC, is a single-shot variant of Differential Phase Contrast (DPC, which recovers the phase of a sample from images with asymmetric illumination. We employ partially coherent illumination to achieve resolution corresponding to 2× the objective NA. Quantitative phase can then be used to synthesize DIC and phase contrast images or extract shape and density. We demonstrate amplitude and phase recovery at camera-limited frame rates (50 fps for various in vitro cell samples and c. elegans in a micro-fluidic channel.

  13. Single-shot dual-wavelength in-line and off-axis hybrid digital holography

    Science.gov (United States)

    Wang, Fengpeng; Wang, Dayong; Rong, Lu; Wang, Yunxin; Zhao, Jie

    2018-02-01

    We propose an in-line and off-axis hybrid holographic real-time imaging technique. The in-line and off-axis digital holograms are generated simultaneously by two lasers with different wavelengths, and they are recorded using a color camera with a single shot. The reconstruction is carried using an iterative algorithm in which the initial input is designed to include the intensity of the in-line hologram and the approximate phase distributions obtained from the off-axis hologram. In this way, the complex field in the object plane and the output by the iterative procedure can produce higher quality amplitude and phase images compared to traditional iterative phase retrieval. The performance of the technique has been demonstrated by acquiring the amplitude and phase images of a green lacewing's wing and a living moon jellyfish.

  14. A versatile diffractive maskless lithography for single-shot and serial microfabrication.

    Science.gov (United States)

    Jenness, Nathan J; Hill, Ryan T; Hucknall, Angus; Chilkoti, Ashutosh; Clark, Robert L

    2010-05-24

    We demonstrate a diffractive maskless lithographic system that is capable of rapidly performing both serial and single-shot micropatterning. Utilizing the diffractive properties of phase holograms displayed on a spatial light modulator, arbitrary intensity distributions were produced to form two and three dimensional micropatterns/structures in a variety of substrates. A straightforward graphical user interface was implemented to allow users to load templates and change patterning modes within the span of a few minutes. A minimum resolution of approximately 700 nm is demonstrated for both patterning modes, which compares favorably to the 232 nm resolution limit predicted by the Rayleigh criterion. The presented method is rapid and adaptable, allowing for the parallel fabrication of microstructures in photoresist as well as the fabrication of protein microstructures that retain functional activity.

  15. Pulsed laser deposition of lysozyme: the dependence on shot numbers and the angular distribution

    DEFF Research Database (Denmark)

    Constantinescu, C.; Matei, A.; Schou, Jørgen

    2013-01-01

    The ejection of molecules from a pressed solid target of lysozyme induced by laser ablation in the UV-regime at a wavelength of 355 nm was investigated. The ablation studies were carried out in vacuum at a laser fluence of 2 J/cm2 for which a significant fraction of proteins remains intact....... This was verified by matrix-assisted laser desorption ionization (MALDI) spectrometry of thin films deposited on silicon substrates. The deposition rate of lysozyme was found to decrease with the number of shots and was correlated with increasing thermal damage of the lysozyme. This was monitored by measurements...... of the optical reflectivity of dry lysozyme. The angular distribution of the mass deposition can be fitted well by Anisimov’s hydrodynamic model. The total deposited yield over the entire hemisphere from direct laser ablation of lysozyme was estimated from this model and found to be three orders of magnitude...

  16. Near shot-noise limited time-resolved circular dichroism pump-probe spectrometer

    Science.gov (United States)

    Stadnytskyi, Valentyn; Orf, Gregory S.; Blankenship, Robert E.; Savikhin, Sergei

    2018-03-01

    We describe an optical near shot-noise limited time-resolved circular dichroism (TRCD) pump-probe spectrometer capable of reliably measuring circular dichroism signals in the order of μdeg with nanosecond time resolution. Such sensitivity is achieved through a modification of existing TRCD designs and introduction of a new data processing protocol that eliminates approximations that have caused substantial nonlinearities in past measurements and allows the measurement of absorption and circular dichroism transients simultaneously with a single pump pulse. The exceptional signal-to-noise ratio of the described setup makes the TRCD technique applicable to a large range of non-biological and biological systems. The spectrometer was used to record, for the first time, weak TRCD kinetics associated with the triplet state energy transfer in the photosynthetic Fenna-Matthews-Olson antenna pigment-protein complex.

  17. Cardiovascular magnetic resonance of myocardial infarction after blunt chest trauma: a heartbreaking soccer-shot

    Directory of Open Access Journals (Sweden)

    Fogarassy Peter

    2009-10-01

    Full Text Available Abstract Cardiac injury occasionally occurs as a result of blunt chest trauma. Most cardiac complications in chest trauma are due to myocardial contusion rather than direct damage to the coronary arteries. However, traumatic coronary injury has been reported, and a variety of underlying pathophysiological mechanisms have been proposed. We present a 26 year old patient presenting with an acute coronary syndrome as a consequence of a soccer-shot impact to the chest. CMR showed apical inferior infarction, as well as multiple small septal lesions which were presumed to have resulted from embolization. The culprit lesion was a proximal 75% LAD stenosis with a prominent plaque-rupture and thrombus-formation, and the distal LAD was occluded by thromboembolic material.

  18. Numerical Study of Mechanical Response of Pure Titanium during Shot Peening

    Science.gov (United States)

    Wang, Y. M.; Cheng, J. P.; Yang, H. P.; Zhang, C. H.

    2018-05-01

    Mechanical response of pure titanium impacted by a steel ball was simulated using finite element method to investigate stress and strain evolution during shot peening. It is indicated that biaxial residual stress was obtained in the surface layer while in the interior triaxial residual stress existed because the S33 was comparable to S11 and S22. With decreasing the depth from the top surface, the stress was higher during impacting, but the stress relief extent became more significant when the ball rebounded. Therefore the maximum residual stress was formed in the subsurface layer with depth of 130 μm. As for the residual strain, it is shown that the maximum residual strain LE33 was obtained at the depth of 60 μm corresponding to the maximum shear stress during impacting.

  19. Ruin Probabilities and Aggregrate Claims Distributions for Shot Noise Cox Processes

    DEFF Research Database (Denmark)

    Albrecher, H.; Asmussen, Søren

    claim size is investigated under these assumptions. For both light-tailed and heavy-tailed claim size distributions, asymptotic estimates for infinite-time and finite-time ruin probabilities are derived. Moreover, we discuss an extension of the model to an adaptive premium rule that is dynamically......We consider a risk process Rt where the claim arrival process is a superposition of a homogeneous Poisson process and a Cox process with a Poisson shot noise intensity process, capturing the effect of sudden increases of the claim intensity due to external events. The distribution of the aggregate...... adjusted according to past claims experience....

  20. Continual and One-Shot Learning Through Neural Networks with Dynamic External Memory

    DEFF Research Database (Denmark)

    Lüders, Benno; Schläger, Mikkel; Korach, Aleksandra

    2017-01-01

    it easier to find unused memory location and therefor facilitates the evolution of continual learning networks. Our results suggest that augmenting evolving networks with an external memory component is not only a viable mechanism for adaptive behaviors in neuroevolution but also allows these networks...... a new task is learned. This paper takes a step in overcoming this limitation by building on the recently proposed Evolving Neural Turing Machine (ENTM) approach. In the ENTM, neural networks are augmented with an external memory component that they can write to and read from, which allows them to store...... associations quickly and over long periods of time. The results in this paper demonstrate that the ENTM is able to perform one-shot learning in reinforcement learning tasks without catastrophic forgetting of previously stored associations. Additionally, we introduce a new ENTM default jump mechanism that makes...