WorldWideScience

Sample records for shot mr-cholangiopancreatography mrcp

  1. MRCP. Magnetic resonance cholangiopancreatography; MRCP. Magnetresonanzcholangiopankreatografie

    Energy Technology Data Exchange (ETDEWEB)

    Kinner, Sonja [Wisconsin-Madison Univ., Madison, WI (United States). Dept. of Radiology; Lauenstein, Thomas [Evangelisches Krankenhaus Duesseldorf (Germany). Radiologie

    2016-06-15

    Magnetic resonance cholangiopancreatography (MRCP) is a special MR technique to display and analyze the biliary tract and pancreatic ducts. MRCP sequences are equivalent to endoscopic retrograde cholangiopancreatography (ERCP) for diagnostic purposes due to technical developments of the classical T2 weighted MRCP sequences and the availability of contrast enhanced T1 weighted sequences. Therefore, MRCP plays a fundamental role in the diagnoses of hepatobliary and pancreatic diseases, which are presented in this review article as are technical details of sequence acquisitions and the underlying anatomy.

  2. Contribution of abdoscan using MR cholangio-pancreatography and MR urography

    International Nuclear Information System (INIS)

    Lecesne, R.; Drouillard, J.; Cisse, R.; Schiratti, M.

    1998-01-01

    MR cholangio-pancreatography (MRCP) and MR Urography (MRU) are promising recent imaging modalities. Oral magnetic particles (Abdoscan, Nycomed SA, Oslo, Norway) is an negative contrast agent eliminating signal intensity of the gastro-intestinal tract thus improvising image quality at MRCP and MRU. (author)

  3. 3 T MR cholangiopancreatography appearances of biliary ascariasis

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Z.X., E-mail: hangzhoudzx73@126.co [Department of Radiology, Zhejiang Provincial People' s Hospital, Hangzhou (China); Yuan, J.H. [Department of Radiology, Zhejiang Provincial People' s Hospital, Hangzhou (China); Chong, V. [Department of Diagnostic Imaging, National University Health System, Yong Loo Lin School of Medicine, National University of Singapore (Singapore); Zhao, D.J. [Department of Hepatobiliary Surgery, Zhejiang Provincial People' s Hospital, Hangzhou (China); Chen, F.H.; Li, Y.M. [Department of Radiology, Zhejiang Provincial People' s Hospital, Hangzhou (China)

    2011-03-15

    Aim: To evaluate the 3 T MR cholangiopancreatography (MRCP) appearances of biliary ascariasis. Materials and methods: Nine patients with a MRCP diagnosis of biliary ascariasis were reviewed. All patients had endoscopic retrograde cholangiopancreatography (ERCP) or surgical confirmation of the disease. Results: On thin-slab MRCP imaging, Ascaris worms are clearly demarcated within the biliary tree. All the identified worms demonstrated a characteristic three-parallel-lines appearance. The middle high-signal intensity line is sandwiched between two low-signal intensity lines and they are in turn surrounded by high signal bile. On thick-slab MRCP the worms also show the three-line sign but with less clarity. However, thick-slab MRCP has the advantage of providing three-dimensional ERCP-like images of the pancreaticobiliary system. Conclusion: The 'three-line' sign appears to be a characteristic sign of biliary ascariasis on 3 T MRCP.

  4. MR cholangiopancreatography. Comparison of images obtained with 1.0 and 1.5 tesla units

    International Nuclear Information System (INIS)

    Yasui, Masayasu; Ito, Katsuyoshi; Koike, Shinji; Matsunaga, Naofumi

    2002-01-01

    The purpose of this study was to compare the image quality and visualization obtained in MR cholangiopancreatography (MRCP) using different high-field strength (1.0 vs. 1.5 Tesla) MR units and to assess the effect of field strength on MRCP. This study population included 10 healthy volunteers and 37 patients suspected of having pancreatobiliary diseases. MRCP images were obtained using two MR units with different high-field strengths (1.0 and 1.5 Tesla), with half-Fourier acquisition single-shot turbo spin-echo (HASTE) and rapid acquisition by relaxation enhancement (RARE) sequences. The image quality and visualization of each portion of the pancreatobiliary system were graded and recorded using a four-point scale. Additionally, the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured. The SNR and CNR in HASTE sequences acquired with the 1.5 Tesla (T) unit were significantly higher than those acquired with the 1.0 T unit (p=0.001). In qualitative analysis, there were no statistically significant differences in image quality or visualization of the ducts in either HASTE or RARE sequences between 1.0 T and 1.5 T. Our study showed that visual image quality provided by MRCP was equivalent at 1.0 and 1.5 T. (author)

  5. Comparison between magnetic resonance cholangiopancreatography (MRCP) and endoscopic retrograde cholangiopancreatography (ERCP); Comparacion entre calongiografia por resonancia magnetica (CPRM) y colangiografia retrograda endoscopia (CPRE)

    Energy Technology Data Exchange (ETDEWEB)

    Pulpeiro, J. R.; Armesto, V. [Clinica Nosa Senora dos Ollos Grandes. Lugo (Spain); Lopez-Roses, L.; Lancho, A.; Gonzalez, A. [Hospital Xeral. Lugo (Spain)

    2000-07-01

    To assess the correlation between magnetic resonance cholangiopancreatography (MRCP) and endoscopic retrograde cholangiopancreatography (ERCP). The authors carried out a prospective study of 71 patients suspected of having biliary diseases. MRCP was performed, followed by ERCP.MRCP was done with a 1.5-T system using hypergradients, abdominal phase array coil and single-shot fast spin-echo (SSFSE) sequences with maximum signal intensity in T2-weighted images. This sequence only provides images of the fluids, similar to those obtained with ERCP. The results of ERCP were employed as a reference standard. Thirty patients were found to have stenosis (19 malignant and 11 benign). 25 had choledocholithiasis and 16 showed no abnormal findings. The correlation was complete in patients with stenosis. MRCP detected 23 cases of choledocholithiasis (ERCP was normal in the remaining two patients, but calculi were discovered on shpincterotomy). MRCP confirmed the normal condition of the bile duct in 12 of the 16 patients free of biliary disease (2 patients in whom ERCP had been normal had been diagnosed as having bile duct dilatation due to choledocholithiasis 24 hours and 10 days earlier, respectively, and two cases of presented ectasia due to fibrosis of the sphincter of Oddi showed good emptying during ERCP). MRCP using SSFSE is highly correlated with ERCP, which should be reserved for cases in which the diagnosis is in doubt or endoscopic management is necessary. (Author) 25 refs.

  6. Assessment of the form and patency of the pancreatic duct by magnetic resonance cholangiopancreatography (MRCP)

    International Nuclear Information System (INIS)

    Kitamura, Masaya; Takahashi, Tuyoshi; Yoshida, Muneki; Shimada, Ken; Kakita, Akira; Isobe, Yoshinori

    1999-01-01

    There have been no reliable methods for the assessment of the patency of an end-to-side style pancreaticojejunal anastomosis in Whipple procedure. We evaluated the ability of MR-Cholangiopancreatography (MRCP) to assess the form and patency of the pancreatic duct in 181 patients. The pancreatic duct was displayed on MRCP in 70.9% of the patients. The domostrative rate of the pancreatic duct on MRCP and the PFD test were well correlated (p=0.031). Further, we assessed the patency of pancreaticojejunal anastomosis in Whipple procedure by MRCP following a secretin load. It was considered that the pancreatic duct to be patent when pancreatic excretion into the jejunum had increased and/or the ability to display the pancreatic duct had improved on MRCP following an i.v. load of secretin. A secretin-loading MRCP was suggested to be of much help in the assessment of the patency of pancreaticojejunostomy in patients undergoing Whipple procedure for a long-term follow up. (author)

  7. Assessment of the form and patency of the pancreatic duct by magnetic resonance cholangiopancreatography (MRCP)

    Energy Technology Data Exchange (ETDEWEB)

    Kitamura, Masaya; Takahashi, Tuyoshi; Yoshida, Muneki; Shimada, Ken; Kakita, Akira; Isobe, Yoshinori [Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Medicine

    1999-02-01

    There have been no reliable methods for the assessment of the patency of an end-to-side style pancreaticojejunal anastomosis in Whipple procedure. We evaluated the ability of MR-Cholangiopancreatography (MRCP) to assess the form and patency of the pancreatic duct in 181 patients. The pancreatic duct was displayed on MRCP in 70.9% of the patients. The domostrative rate of the pancreatic duct on MRCP and the PFD test were well correlated (p=0.031). Further, we assessed the patency of pancreaticojejunal anastomosis in Whipple procedure by MRCP following a secretin load. It was considered that the pancreatic duct to be patent when pancreatic excretion into the jejunum had increased and/or the ability to display the pancreatic duct had improved on MRCP following an i.v. load of secretin. A secretin-loading MRCP was suggested to be of much help in the assessment of the patency of pancreaticojejunostomy in patients undergoing Whipple procedure for a long-term follow up. (author)

  8. MR cholangiopancreatography in children: feasibility, safety, and initial experience

    International Nuclear Information System (INIS)

    Delaney, Lisa; Karmazyn, Boaz; Akisik, M.F.; Jennings, S.G.; Applegate, Kimberly E.

    2008-01-01

    The indications for MR cholangiopancreatography (MRCP) in children, and its safety and findings, might differ from those in adults and are not well described. To investigate the safety, feasibility, and accuracy of MRCP in children. We reviewed all prospective MRCP reports, noting the indication, the use of secretin, endoscopic retrograde cholangiopancreatography (ERCP) findings, and patient outcomes. Two readers reviewed each MRCP study by consensus to rate duct visualization and compare pancreatic duct sizes before and after secretin administration (paired t-test). The likelihood of a normal versus an abnormal MRCP study was compared by gender, pancreatitis as the primary indication, secretin use, and whether ERCP was performed (Fisher's exact test), as well as age (t-test). A total of 85 MRCP studies were performed in children (mean age 10.3 years), most commonly for evaluation of pancreatitis (n=47, 55%); 41 (48%) used secretin and 39 (46%) used a negative oral contrast agent. Of the 85 studies, 72 (85%) had excellent image quality and 43 were normal. ERCP was performed after 16 of the 85 MRCP studies (19%); the diagnoses were concordant with those of MRCP in 13 (81%). There were 42 abnormal MRCP studies, and these were more likely to be in girls (P=0.03) and in children who had undergone ERCP (P<0.01). Secretin and the negative oral contrast agent were well-tolerated. Secretin improved duct visualization (P<0.001). MRCP safely and accurately depicted pancreaticobiliary anatomy in children. The use of secretin improved visualization of the pancreatic duct. (orig.)

  9. Magnetic Resonance Imaging Including Magnetic Resonance Cholangiopancreatography for Tumor Localization and Therapy Planning in Malignant Hilar Obstructions

    International Nuclear Information System (INIS)

    Haenninen, E.L.

    2005-01-01

    PURPOSE: To assess image quality and overall accuracy of magnetic resonance imaging (MRI), including two magnetic cholangiopancreatography (MRCP) techniques, for the diagnostics and preoperative work-up of malignant hilar obstructions. MATERIAL AND METHODS: Thirty-one patients with malignant hilar obstructions (hilar cholangiocarcinoma, n=30; hepatocellular carcinoma, n=1) received MRCP by two techniques (single-shot thick-slab and multisection thin-slice MRCP) and unenhanced and contrast material-enhanced MRI. MR assessment included the evaluation of image quality and visualization of bile ducts (5-point scale), and the classification of tumor status. MR results were subsequently correlated with the results from surgery and pathology. RESULTS: The maximum intensity projections of multisection thin-slice MRCP had significantly more artifacts compared to MRCP in the single-shot thick-slab technique, and overall image quality of single-shot thick-slab MRCP was rated significantly superior compared to multisection thin-slice MRCP (4.4 ± 0.7 and 4.1 ± 0.9, respectively). Moreover, ductal visualization of different parts of the biliary system was rated superior with single-shot thick-slab MRCP. In contrast, the original data from multisection thin slice MRCP facilitated visualization of periductal lesions and adjacent structures. Overall MR accuracy for the assessment of tumor status, periductal infiltration, and lymph node metastases was 90%, 87%, and 66%, respectively. CONCLUSION: For evaluation of malignant hilar obstructions, MRCP by the single-shot thick-slab technique had superior image quality and fewer artifacts; in contrast, besides sole biliary visualization, multisection MRCP depicted complementary adjacent parenchymal and periductal structures. We therefore recommend MRI, with a combination of both MRCP techniques, for the diagnostic work-up and therapy planning of malignant hilar obstructions

  10. MR cholangiopancreatography diagnosis for cholangitis caused by clonorchis sinensis

    International Nuclear Information System (INIS)

    Cui Bing; Hu Qiugen; Wang Yan

    2003-01-01

    Objective: To evaluate the MR cholangiopancreatography (MRCP) diagnosis for cholangitis caused by clonorchis sinensis. Methods: Fifty-four cases with cholangitis caused by clonorchis sinensis were examined by MRCP (3D FASE-Heavy T 2 WI sequence). The results of MRCP were compared with that of ERCP, laparoscopy, and pathology. Results: The diagnostic accuracy for the cause of the disease was 88.9%. Main findings on MRCP included slight dilation of the intra-hepatic biliary duct (n=46), small cystiform dilation of peripheral biliary ending (n=43), extra-hepatic biliary dilations (n=15) and strictures (n=19), and low signal intensity filling defect in the common bile duct and gallbladder (n=6). Conclusion: MRCP of biliary tree images can be obtained with 3D FASE Heavy T 2 WI sequence in considerable details. The characteristic of the cholangitis caused by clonorchis sinensis on MRCP was the slight dilation or stricture of extensive intra-hepatic biliary duct, combined with small cystiform dilation of peripheral biliary ending. MRCP was an ideal technique in diagnosing the disease

  11. Pancreatic adenocarcinoma: combination of MR imaging, MR angiography and MR cholangiopancreatography for the diagnosis and assessment of resectability

    International Nuclear Information System (INIS)

    Catalano, C.; Pavone, P.; Laghi, A.; Panebianco, V.; Scipioni, A.; Fanelli, F.; Brillo, R.; Passariello, R.

    1998-01-01

    The purpose of this study was to determine the possibility of integrating MR cholangiopancreatography (MRCP) and MR angiography (MRA) to conventional MR images in the diagnosis and assessment of resectability of pancreatic adenocarcinoma. Twenty-three patients with pancreatic adenocarcinoma were prospectively examined with MR. Conventional MR images were acquired in all patients. Three-dimensional MRCP and MRA images were acquired in all patients with suspected biliary and vascular involvement. Acquisition time was less than 45 min in all cases. Images were independently evaluated by two radiologists, with final reading decided by consensus among readers. Diagnosis was confirmed with surgery in 16 patients and with percutaneous biopsy in 7. Concordance among readers was high with a kappa value of 0.83. Pancreatic adenocarcinoma was observed in all patients. Correct assessment of unresectability due to vascular involvement was found in 22 of 23 patients. Biliary obstruction was evident in 13 patients, involving the biliary and pancreatic ducts in 9 and the biliary ducts only in 4. Technical advances permit extensive use of MRI in the evaluation of abdominal pathologies. The combination of MR imaging, MRCP, and MRA can provide sufficient information for the diagnosis and assessment of resectability of pancreatic adenocarcinoma, which otherwise would require three different exams. (orig.)

  12. Evaluation fo MR cholangio-pancreatography in the diagnosis of pancreaticobiliary diseases. In comparison with ERCP

    International Nuclear Information System (INIS)

    Saito, Masayuki; Watahiki, Hajime; Yamamoto, Hideaki

    1995-01-01

    The clinical usefulness of MR cholangio-pancreatography (MRCP) by fast spin echo method was compared with that of endoscopic retrograde cholangio pancreatography (ERCP). In MRCP, favorable images of bile and pancreatic ducts were obtained in 66.7% (78/117) and bile duct images in 16.2% (19/117), showing the overall efficacy rate of 92.9% (97/117). Seventy-seven of these images were compared with simultaneously obtained favorable ERCP images. The excellent and favorable rate of MRCP reached 84.5% (65/77), showing clinical usefulness of MRCP. Obscure images were considered due to insufficient breath-hold time. (S.Y.)

  13. The role of MR cholangiopancreatography in acute abdominal pain (a case study)

    International Nuclear Information System (INIS)

    Obradovic, G.

    2000-01-01

    Rapid technological advances have resulted in improved Magnetic Resonance Imaging (MRI) of the abdomen. In particular, the development of single breath hold sequences have led to a resurgence in imaging of the binary tree and pancreatic duct. For this reason, Magnetic Resonance Cholangiopancreatography (MRCP) is recognised as a valuable tool which is safe, fast and noninvasive. This case study demonstrates that MRCP could identify the intrahepatic duct obstruction adequately, so that the appropriate course of management could be readily instigated. In addition, the excellent quality of MR imaging will lead to an increase in referrals for MRCP if the modality is available and there are no patient contra-indications. Copyright (1999) Australian Institute of Radiography

  14. Clinical evaluation of further-developed MRCP sequences in comparison with standard MRCP sequences

    International Nuclear Information System (INIS)

    Hundt, W.; Scheidler, J.; Reiser, M.; Petsch, R.

    2002-01-01

    The purpose of this study was the comparison of technically improved single-shot magnetic resonance cholangiopancreatography (MRCP) sequences with standard single-shot rapid acquisition with relaxation enhancement (RARE) and half-Fourier acquired single-shot turbo spin-echo (HASTE) sequences in evaluating the normal and abnormal biliary duct system. The bile duct system of 45 patients was prospectively investigated on a 1.5-T MRI system. The investigation was performed with RARE and HASTE MR cholangiography sequences with standard and high spatial resolutions, and with a delayed-echo half-Fourier RARE (HASTE) sequence. Findings of the improved MRCP sequences were compared with the standard MRCP sequences. The level of confidence in assessing the diagnosis was divided into five groups. The Wilcoxon signed-rank test at a level of p<0.05 was applied. In 15 patients no pathology was found. The MRCP showed stenoses of the bile duct system in 10 patients and choledocholithiasis and cholecystolithiasis in 16 patients. In 12 patients a dilatation of the bile duct system was found. Comparison of the low- and high spatial resolution sequences and the short and long TE times of the half-Fourier RARE (HASTE) sequence revealed no statistically significant differences regarding accuracy of the examination. The diagnostic confidence level in assessing normal or pathological findings for the high-resolution RARE and half-Fourier RARE (HASTE) was significantly better than for the standard sequences. For the delayed-echo half-Fourier RARE (HASTE) sequence no statistically significant difference was seen. The high-resolution RARE and half-Fourier RARE (HASTE) sequences had a higher confidence level, but there was no significant difference in diagnosis in terms of detection and assessment of pathological changes in the biliary duct system compared with standard sequences. (orig.)

  15. Primary biliary cirrhosis: Evaluation with T2-weighted MR imaging and MR cholangiopancreatography

    Energy Technology Data Exchange (ETDEWEB)

    Haliloglu, Nuray [Ankara University, Faculty of Medicine, Department of Radiology, Ibni Sina Hospital, 06100 Ankara (Turkey)], E-mail: nurayunsal2@hotmail.com; Erden, Ayse; Erden, Ilhan [Ankara University, Faculty of Medicine, Department of Radiology, Ibni Sina Hospital, 06100 Ankara (Turkey)

    2009-03-15

    Purpose: The aim of this retrospective study is to evaluate the role of T2-weighted MR imaging (MRI) and MR cholangiopancreatography (MRCP) findings in the diagnosis of primary biliary cirrhosis (PBC). Materials and methods: The following T2-weighted MRI and MRCP findings: segmental hepatic atrophy/hypertrophy, irregular liver surface, parenchymal lace-like fibrosis, rounded low signal intensity lesions centering portal vein branches (periportal halo sign), periportal hyperintensity (cuffing), splenomegaly, ascites, lymphadenopathy, venous collaterals, and the configuration of intrahepatic biliary ducts were reviewed for their diagnostic significance by two observers in 13 female patients (mean age: 49 years) with PBC. Discordant readings of the observers were resolved at consensus. Results: When parenchymal lace-like fibrosis and periportal halo sign were seen together the sensitivity of T2-weighted MR images was 69%. In six cases periportal hyperintensity (cuffing) and periportal halo sign were seen together. Segmental hypertrophy was present in nine patients and hepatic surface irregularity due to regenerative nodules were present in 10 patients. Lymphadenopathy was seen in 10, splenomegaly was seen in 5, collateral vascular structures were seen in 2 and minimal perihepatic free fluid was seen in 2 patients. MRCP images revealed various mild irregularity in the intrahepatic bile ducts in 8 patients and focal narrowing at the common bile duct level in 1 patient. Conclusion: MRI and MRCP may support the clinical and laboratory findings of PBC even in the early stages of the disease. MRI can also be a choice of method for the recommended prolonged follow up.

  16. Primary biliary cirrhosis: Evaluation with T2-weighted MR imaging and MR cholangiopancreatography

    International Nuclear Information System (INIS)

    Haliloglu, Nuray; Erden, Ayse; Erden, Ilhan

    2009-01-01

    Purpose: The aim of this retrospective study is to evaluate the role of T2-weighted MR imaging (MRI) and MR cholangiopancreatography (MRCP) findings in the diagnosis of primary biliary cirrhosis (PBC). Materials and methods: The following T2-weighted MRI and MRCP findings: segmental hepatic atrophy/hypertrophy, irregular liver surface, parenchymal lace-like fibrosis, rounded low signal intensity lesions centering portal vein branches (periportal halo sign), periportal hyperintensity (cuffing), splenomegaly, ascites, lymphadenopathy, venous collaterals, and the configuration of intrahepatic biliary ducts were reviewed for their diagnostic significance by two observers in 13 female patients (mean age: 49 years) with PBC. Discordant readings of the observers were resolved at consensus. Results: When parenchymal lace-like fibrosis and periportal halo sign were seen together the sensitivity of T2-weighted MR images was 69%. In six cases periportal hyperintensity (cuffing) and periportal halo sign were seen together. Segmental hypertrophy was present in nine patients and hepatic surface irregularity due to regenerative nodules were present in 10 patients. Lymphadenopathy was seen in 10, splenomegaly was seen in 5, collateral vascular structures were seen in 2 and minimal perihepatic free fluid was seen in 2 patients. MRCP images revealed various mild irregularity in the intrahepatic bile ducts in 8 patients and focal narrowing at the common bile duct level in 1 patient. Conclusion: MRI and MRCP may support the clinical and laboratory findings of PBC even in the early stages of the disease. MRI can also be a choice of method for the recommended prolonged follow up.

  17. Gadopentetate dimeglumine-enhanced MR cholangiopancreatography in infants with cholestasis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Mi-Jung; Kim, Myung-Joon [Yonsei University, College of Medicine, Department of Radiology and Research Institute of Radiological Science, Severance Children' s Hospital, Seoul (Korea, Republic of); Severance Pediatric Liver Disease Research Group, Seoul (Korea, Republic of); Yoon, Choon-Sik [Yonsei University, College of Medicine, Department of Radiology, Gangnam Severance Hospital, Seoul (Korea, Republic of); Chung, Yong Eun [Yonsei University, College of Medicine, Department of Radiology and Research Institute of Radiological Science, Severance Children' s Hospital, Seoul (Korea, Republic of); Han, Seok Joo [Yonsei University, College of Medicine, Department of Pediatric Surgery, Severance Children' s Hospital, Seoul (Korea, Republic of); Severance Pediatric Liver Disease Research Group, Seoul (Korea, Republic of); Koh, Hong [Yonsei University, College of Medicine, Department of Pediatric Gastroenterology, Hepatology, and Nutrition, Severance Children' s Hospital, Seoul (Korea, Republic of); Severance Pediatric Liver Disease Research Group, Seoul (Korea, Republic of)

    2011-04-15

    Biliary atresia (BA) is a progressive, obliterative cholangiopathy that occurs in neonates with hepatic portoenterostomy the treatment of choice, but early surgery is important for optimum outcomes. MRI, including MR cholangiopancreatography (MRCP) may be a diagnostically useful alternative to US, but the heavily T2-weighted sequences used include not only bile duct signals, but also other heterogeneously high signal intensities from surrounding structures. To evaluate the effects of gadolinium when used to decrease background signal intensity on T2-weighted MR cholangiopancreatography (MRCP) in infants and to evaluate the qualitative improvement of the depiction of the common bile duct (CBD) for evaluating neonatal cholestasis. Our Institutional Review Board approved this prospective study. MRCP was performed with gadopentetate dimeglumine injection using a 1.5-T scanner. Pre- and postcontrast MRCP images were compared. Forty-nine infants (male:female = 21:28; age 0-12 months, mean 2.3) were included. The final diagnoses were biliary atresia (BA) in 28 cases and non-BA in 21. Quantitative analysis was conducted using region-of-interest measurements of mean signal intensities of the liver, pancreatic head and gallbladder (if defined). Qualitative analysis was performed by four radiologists who subjectively scored image confidence in the presence of CBD on a 4-point scale (0 for definitely absent, 1 for probably absent, 2 for probably present, and 3 for definitely present). The signal-to-noise ratios were significantly decreased in the liver and pancreatic head after contrast medium enhancement (mean 5.7{yields}4.0 in liver and mean 44.9{yields}12.7 in the pancreatic head; P < 0.0001), and this finding was constant in both the BA and the non-BA group. The mean confidence score in the presence of CBD decreased in the BA group (0.9{yields}0.5; P < 0.0001), but did not change significantly in the non-BA group (2.0{yields}2.1; P = 0.459) after contrast medium

  18. The primary applications of Gd-DTPA as an oral negative gastrointestinal contrast agent for MRCP

    International Nuclear Information System (INIS)

    Chen Yanping; Zhang Xuelin; Cheng Guanxun; Chang Renmin; Zhang Yuzhong; Cang Peng; Xia Qiong

    2003-01-01

    Objective: Using oral Gd-DTPA as a negative contrast agent to null the bowel signal during MR cholangiopancreatography (MRCP) to improve the quality of MRCP. Methods: A phantom study was performed to select the optimal concentration of Gd-DTPA to be used as an oral negative contrast agent in MRCP. 15 patients suspected of biliary tract and pancreatic disease were performed with MRCP before and after using 250 ml oral contrast agents (1:5 diluted Gd-DTPA, 1.488 g/L). All MR images were acquired using a 1.5 T whole body MR scanner (Vision Plus, Siemens). MRCP was acquired using two-dimensional single slice fast spin-echo sequence and HASTE (half-fourier acquisition single-shot fast spin echo) sequence. Results: The phantom study showed that the dilution ratio 1:5 of Gd-DTPA oral contrast agent was best in decreasing the signal intensity both in T 2 WI (59.3%) and in HASTE sequence (82.45%). All the dilution ratio of Gd-DTPA oral contrast agent decreased the signal intensity up to 90% on single slice MRCP. In all the patients the high signal intensity from the stomach and intestinal fluid was completely suppressed. The depictions of common bile duct and pancreatic duct were markedly improved by the oral contrast agent (P<0.05). Conclusion: 1:5 diluted (1.488 g/L) oral MR contrast agent Gd-DTPA can be an effective and safe negative contrast agent in eliminating signal intensity of the gastrointestinal tract, thus improving the depiction of the biliary system in MRCP

  19. Magnetic Resonance Cholangiopancreatography: Image Quality, Ductal Morphology, and Value of Additional T2- and T1-weighted Sequences for the Assessment of Suspected Pancreatic Cancer

    International Nuclear Information System (INIS)

    Lopez Haenninen, E.; Ricke, H.; Amthauer, H.; Roettgen, R.; Boehmig, M.; Langrehr, J.; Pech, M.; Denecke, T.; Rosewicz, S.; Felix, R.

    2005-01-01

    Purpose: To assess image quality and duct morphology on magnetic resonance cholangiopancreatography (MRCP) and also the value of additional T2- and T1-weighted sequences for differentiation of benignity and malignancy in patients with suspected pancreatic tumors. Material and Methods: One-hundred-and-fourteen patients received MRCP and unenhanced and contrast material-enhanced MR imaging. MR results were analyzed independently by two blinded readers, and subsequently correlated with the results from surgery, biopsy, and follow-up. Assessment included the evaluation of image quality, duct visualization and morphology, and the differentiation of pancreatic lesion status (benign versus malignant).Results: Overall, 49 patients had benign final diagnoses, while 65 had a malignant diagnosis. Image quality of single-shot thick-slab MRCP was rated significantly better than the MIP images of multisection MRCP. With MRCP alone, the two readers' accuracy in the assessment of pancreatic lesion status was 72% (95% CI, 64% to 83%) and 69% (95% CI, 56% to 77%), respectively; with the addition of T2- and T1-weighted images the accuracy significantly improved to 89% (95% CI, 82% to 95%) and 84% (95% CI, 77% to 92%) for readers 1 and 2, respectively. Conclusion: Single-shot thick-slab MRCP and multisection MRCP provide complementary results; however, single-shot MRCP had superior image quality. Moreover, assessment of ductal morphology with MRCP alone facilitated the diagnosis of different pathologic conditions of the pancreatobiliary system in the majority of patients. However, with the addition of T2- and T1-weighted sequences the overall diagnostic accuracy was significantly improved and thus we consider that a comprehensive MR approach should comprise both MRCP techniques and parenchymal sequences

  20. The value of adding conventional MR imaging to MR cholangiopancreatography in differentiation of benign and malignant causes of postoperative disorders

    International Nuclear Information System (INIS)

    Sun Changjin; Zhou Xiangping; Song Bin; Chen Xian; Liu Rongbo; Yan Zhihan; Xiong Yan

    2003-01-01

    Objective: To determine the value of conventional T 1 - and T 2 -weighted images and gadolinium-enhanced magnetic resonance (MR) images as a supplement to MR cholangiopancreatography (MRCP) in differentiation of benign from malignant causes of postoperative disorders in the biliary ductal system. Methods: Sixty-one patients with postoperative disorders in the biliary ductal system with proved causes underwent MRCP, conventional T 1 - and less heavily T 2 -weighted images, as well as gadolinium-enhanced images. Two radiologists independently reviewed MRCP images alone, MRCP plus nonenhanced T 1 - and T 2 -weighted images, and MRCP plus nonenhanced and gadolinium-enhanced images. The results of MR findings were compared with that of the surgical findings and the pathology. Results: For the diagnosis of postoperative disorders only with MRCP images, the sensitivity, specificity, and accuracy was 42.1%, 80.9% and 68.9% for radiologist 1 and 47.4%, 85.7%, and 73.8% for radiologist 2, respectively. When MRCP images were interpreted with T 1 - and T 2 -weighted images, the sensitivity, specificity, and accuracy was 78.9%, 92.9% and 88.5% for radiologist 1 and, 78.9%, 95.2%, and 90.2% for radiologist 2, respectively. When MRCP images were combined with both nonenhanced T 1 - and T 2 -weighted images and enhanced MR images, the sensitivity, specificity, and accuracy was 84.2%, 95.2% and 91.8% for radiologist 1 and 84.2%, 97.6%, and 93.4% for radiologist 2, respectively. There was no significant difference between the 2 readers (P>0.05). For differentiation of benign from malignant causes of postoperative disorders, the area under the receiver operating characteristic curve (Az) was significantly larger for MRCP images interpreted with T 1 - and T 2 weighted images (0.907 for reader 1, 0.920 for reader 2) than for MRCP images alone (0.682 reader 1, 0.714 for reader 2) (P 1 - and T 2 -weighted images did not significantly increase the accuracy (Az = 0.948 for reader 1, 0

  1. Magnetic resonance cholangiopancreatography findings of pancreatic diseases: quantitative analysis

    International Nuclear Information System (INIS)

    Xu Jun; Lu Jianping; Wang Jian; Wang Fei; Liu Qi; Wang Li; Gong Jianguo; Jin Aiguo; Zeng Hao

    2004-01-01

    Objective: To study the MR cholangiopancreatography (MRCP) characteristics of different pancreatic diseases, and to identify the diagnostic value of MRCP for pancreatic diseases. Methods: One hundred and eleven patients with suspected pancreatic diseases underwent MRCP examination. The MRCP sequences included thick-slice turbo spin echo (TSE) and thin-slice half-Fourier acquisition single shot turbo spin echo (HASTE) sequences. The pancreatic diseases included pancreatic carcinoma (n=46), chronic pancreatitis (n=39), peri-ampullar carcinoma (n=23), and choledocholith (n=3). Results: (1) The abnormal manifestation of pancreatic duct was observed in 37 cases of pancreatic carcinoma, 24 cases of chronic pancreatitis, and 12 cases of peri-ampullar carcinoma. Dilated pancreatic duct with smooth and regular caliber was observed in 33 cases of pancreatic carcinoma, 0 case of chronic pancreatitis, and 12 cases of peri-ampullar carcinoma, and statistical analysis showed significant difference (χ 2 =57.911, P 2 =60.343, P 2 =61.217, P 2 =34.654, P 2 =54.593, P<0.01). Conclusion: Different MRI characteristics were observed in various pancreatic diseases respectively. MRCP can show the subtle differences among the pancreatic diseases, and is very helpful in the diagnosis and differential diagnosis of pancreatic diseases

  2. Comparison of respiratory-triggered 3-D fast spin-echo and single-shot fast spin-echo radial slab MR cholangiopancreatography images in children

    Energy Technology Data Exchange (ETDEWEB)

    Chavhan, Govind B.; Almehdar, Abeer; Gupta, Sumeet [The Hospital for Sick Children and University of Toronto, Department of Diagnostic Imaging, Toronto (Canada); Moineddin, Rahim [University of Toronto, Department of Family and Community Medicine, Toronto (Canada); Babyn, Paul S. [Royal University Hospital, Department of Medical Imaging, Saskatoon (Canada)

    2013-09-15

    The two most commonly performed magnetic resonance cholangiopancreatography (MRCP) sequences, 3-D fast spin-echo (3-D FSE) and single-shot fast spin-echo radial slabs (radial slabs), have not been compared in children. The purpose of this study was to compare 3-D FSE and radial slabs MRCP sequences on a 3-T scanner to determine their ability to show various segments of pancreaticobiliary tree and presence of artifacts in children. We reviewed 79 consecutive MRCPs performed in 74 children on a 3-T scanner. We noted visibility of major ducts on 3-D FSE and radial slabs. We noted the order of branching of ducts in the right and left hepatic ducts and the degree of visibility of the pancreatic duct. Statistical analysis was performed using McNemar and signed rank tests. There was no significant difference in the visibility of major bile ducts and the order of branching in the right hepatic lobe between sequences. A higher order of branching in the left lobe was seen on radial slabs than 3-D FSE (mean order of branching 2.82 versus 2.27; P-value = 0.0002). The visibility of pancreatic duct was better on radial slabs as compared to 3-D FSE (mean value of 1.53 vs. 0.90; P-value < 0.0001). 3-D FSE sequence was artifact-free in 25/79 (31.6%) MRCP exams as compared to radial slabs, which were artifact-free in 18/79 (22.8%) MRCP exams (P-value = 0.0001). There is no significant difference in the visibility of major bile ducts between 3-D FSE and radial slab MRCP sequences at 3-T in children. However, radial slab MRCP shows a higher order of branching in the left hepatic lobe and superior visibility of the pancreatic duct than 3-D FSE. (orig.)

  3. Non-invasive quantification of pancreatic exocrine function using secretin-stimulated MRCP

    International Nuclear Information System (INIS)

    Punwani, S.; Gillams, A.R.; Lees, W.R.

    2003-01-01

    Our objective was to quantify water volume using magnetic resonance cholangiopancreatography (MRCP) sequences and apply this to secretin-stimulated studies with the aim of quantifying pancreatic exocrine function. A commercially available single-shot MRCP sequence was used in conjunction with a body phased-array coil and a 1.5-T MR system. Signal intensity was measured in samples of water, pancreatic, duodenal juice, and secretin-stimulated pancreatic juice. A water phantom was made and MR calculated volumes compared with known water volumes within the phantom. Changes in small intestinal volume in response to secretin were measured in a group of 11 patients with no evidence of pancreatic disease. Changes in water volume were plotted over time. The pancreatic duct diameter before and after secretin was noted and filling defects were sought. All patients also underwent an axial breath-hold T1-weighted gradient-echo sequence and the pancreatic parenchyma was evaluated for size and signal intensity. There was no difference in the signal intensity of the different juice samples. There was excellent correlation between known and calculated MRCP volumes (χ 2 =0.99). All patients demonstrated normal duct morphology on MRCP and normal pancreatic parenchyma on T1-weighted imaging. The mean flow rate in the patient population was 8.1±2.5 ml/s over a median of 7 min (range 5-9 min). The MRCP sequence can be used to measure water volume. Sequential MRCP measurements following secretin permitted calculation of volume change and flow rate. This should prove useful as an indicator of pancreatic exocrine function. (orig.)

  4. Imaging of the normal and abnormal pancreaticobiliary system with single-shot MR cholangiopancreatography: a pictorial review

    International Nuclear Information System (INIS)

    Little, A. F.; Smith, P.J.; Lee, W.K.; Hennessy, O.F.; Lourensz, M.E.; Desmond, P.V.; Banting, S.W.

    1999-01-01

    Magnetic resonance cholangiopancreatography (MRCP) is a rapidly evolving non-invasive imaging modality that produces images of the pancreatic duct and binary tree without the need for intravenous or oral contrast. The images are equivalent to those from endoscopic retrograde cholangiopancreatography (ERCP), but the non-invasive acquisition avoids the morbidity and mortality associated with diagnostic ERCP. Magnetic resonance cholangiopancreatography is indicated in patients who require only a diagnostic ERCP, who fail an ERCP or who are unable to undergo ERCP due to altered post-surgical anatomy. Other evolving indications include triaging of patients with obstructive jaundice into percutaneous or endoscopic management drainage pathways depending on the site, length and nature of the duct obstruction, thereby potentially decreasing the number of failed or unsuccessful ERCP. Preoperative identification of anomalous binary anatomy and choledocholithiasis prior to laparoscopic cholecystectomy promise to modify the pre-operative and operative management of the patient in order to minimize the risk of duct injury and unnecessary intra-operative dissection and cholangiography. The advantages of the technique include its non-invasiveness, the absence of contrast administration, its relative operator independence and the ability to evaluate both sides of an obstructed duct, thereby accurately evaluating stricture morphology and length. The disadvantages of MRCP compared to ERCP include its lack of an immediate therapeutic solution to duct obstruction, procedural cost, unit availability and the inability to evaluate patients with pacemakers or ferromagnetic implants. Copyright (1999) Blackwell Science Pty Ltd

  5. On the appearance of bile in clinical MR cholangiopancreatography

    International Nuclear Information System (INIS)

    Haakansson, K.; Christoffersson, J.O.; Leander, P.; Ekberg, O.; Haakansson, H.O.

    2002-01-01

    Purpose: To study the appearance of bile in clinical MR cholangiopancreatography (MRCP) with special reference to its chemical and physical properties. Material and Methods: Gallbladder bile was collected during surgery from 38 patients and studied with respect to chemical constituents. The relaxation rates 1/T1 and 1/T2 of bile were also determined in vitro. In 16 of these 38 patients, abdominal imaging was performed using MRCP as well as T1-weighted GE sequences. Results: For 9 of the 13 chemical parameters studied, a positive significant correlation with 1/T1 as well as 1/T2 was found. The median relaxation rates 1/T1 and 1/T2 were 0.76 and 1.48/s, respectively. The corresponding ranges were 0.38-3.13/s and 0.70-5.75/s, respectively. On the MRCP images a few patients showed gallbladder of poor visibility due to low signal-to-noise ratio. This coincided with a high relaxation rate 1/T2 of bile. On the T1-weighted GE sequences a few patients showed hyperintense gallbladder relative to liver, coinciding with high relaxation rates 1/T1 of bile. Conclusion: Bile was found to show a large interindividual variation with respect to relaxation rates 1/T1 and 1/T2. The relaxation rates increased with increasing amounts of substances in the bile. For some patients (11%) MRCP imaging is unsuccessful due to high relaxation rate of bile

  6. Magnetic resonance cholangiopancreatography (MRCP) using new negative per-oral contrast agent based on superparamagnetic iron oxide nanoparticles for extrahepatic biliary duct visualization in liver cirrhosis.

    Science.gov (United States)

    Polakova, Katerina; Mocikova, Ingrid; Purova, Dana; Tucek, Pavel; Novak, Pavel; Novotna, Katerina; Izak, Niko; Bielik, Radoslav; Zboril, Radek; Miroslav, Herman

    2016-12-01

    Magnetic resonance cholangiopancreatography (MRCP) is often used for imaging of the biliary tree and is required by surgeons before liver transplantation. Advanced liver cirrhosis and ascites in patients however present diagnostic problems for MRCP. The aim of this study was to find out if the use of our negative per-oral contrast agent containing superparamagnetic iron oxide nanoparticles (SPIO) in MRCP is helpful for imaging of hepatobiliary tree in patients with liver cirrhosis. Forty patients with liver cirrhosis were examined on a 1.5 T MR unit using standard MRCP protocol. Twenty patients (group A) underwent MRCP after administration of per-oral SPIO contrast agent 30 min before examination. In group B, twenty patients were examined without per-oral bowel preparation. Ascites was present in eleven patients from group A and in thirteen patients in group B. Four radiologists analyzed MR images for visibility and delineation of the biliary tree. χ 2 tests were used for comparison of the visibility of intrahepatic and extrahepatic biliary ducts in patients with and without ascites. Better extrahepatic biliary duct visualization and visibility of extraluminal pathologies in patients with ascites was proved after administration of SPIO contrast agent. No statistically significant difference between group A and B was found for visualization of extrahepatic biliary ducts in patients without ascites. Delineation of intrahepatic biliary ducts was independent on bowel preparation. Application of our negative per-oral SPIO contrast agent before MRCP improves the visualization of extrahepatic biliary ducts in patients with ascites which is helpful during the liver surgery, mainly in liver transplantation.

  7. Differential diagnosis of benign and malignant intraductal papillary mucinous tumors of the pancreas: MR cholangiopancreatography and MR angiography

    International Nuclear Information System (INIS)

    Choi, Byung Se; Kim, Tae Kyoung; Kim, Ah Young; Kim, Kyoung Won; Park, Sung Won; Kim, Pyo Nyun; Ha, Kyun Kwon; Lee, Moon Gyu; Kim, Song Cheol

    2003-01-01

    To compare the usefulness of magnetic resonance cholangiopancreatography (MRCP) and MR angiography (MRA) in differentiating malignant from benign intraductal papillary mucinous tumors of the pancreas (IPMTs), and to determine the findings which suggest malignancy. During a 6-year period, 46 patients with IPMT underwent MRCP. Morphologically, tumor type was classified as main duct, branch duct, or combined. The diameter of the main pancreatic duct (MPD), the extent of the dilated MPD, and the location and size of the cystic lesion, septum, and communicating channel were assessed. For all types of IPMTs, enhanced mural nodules and portal vein narrowing were evaluated at MRA. Combined-type IPMTs were more frequently malignant (78%) than benign (42%) (p<0.05). Compared with benign lesions, malignant lesions were larger, and the caliber of the communicating channel was also larger (p < 0.05). Their dilated MPD was more extensive and of greater diameter (p<0.05), and the presence of mural nodules was more frequent (p<0.001). Combined MRCP and MRA might be useful for the differential diagnosis of malignant and benign IPMTs of the pancreas

  8. Value of selective MIP reconstructions of respiratory triggered 3D-TSE-MR cholangiography on a workstation versus standard MIP reconstructions and single-shot MRCP

    International Nuclear Information System (INIS)

    Schaible, R.; Textor, J.; Kreft, B.; Schild, H.; Neubrand, M.

    2001-01-01

    Comparison of anatomical visualisation and diagnostic value of selective MIP reconstructions of respiratory triggered 3D-TSE-MRCP versus standard MIP reconstructions and single-shot MRCP. Material and Methods: 50 patients with pancreaticobiliary disease were examined at 1.5 Tesla (ACS NT II, Philips Medical Systems) using a breath-hold single-shot (SS) and a respiratory triggered 3D-TSE-MRCP technique in 12 standard MIP projections. Additional selective MIP reconstructions with different slice thickness (2, 4, 10 cm) and projections were performed on a workstation. Visualization of the pancreaticobiliary system and the diagnostic value of the examinations were analysed. Results: Single-shot and 3D-TSE in standard projections showed comparable anatomical visualisation. On selective MIP reconstructions the biliary system (SS p [de

  9. MR cholangio-pancreatography using an open, low magnetic field of 0.2 Tesla. Early clinical results and comparison with a higher magnetic field (1.5 Tesla) and with ERCP

    International Nuclear Information System (INIS)

    Wacker, Q.; Branding, G.; Wolf, K.J.; Zimmer, T.; Faiss, S.

    1997-01-01

    Aim: To evaluate MR cholangio-pancreatography (MRCP) using an open low magnetic field apparatus in normals and in patients with mechanical cholestasis. Methods: MRCP was performed on five normals and on 30 patients, using both an 0.2 Tesla and 1.5 Tesla apparatus. With the low field system, rapid acquisition by relaxation enhancement was used, for the high field system, half Fourier acquisition single shot turbo spin-echo sequences were used. In all patients, sonography and ERCP of PTC was performed; 23 underwent surgery. Results: In all normals it was possible to show the bile duct, hepatic duct, gall bladder and intrahepatic ducts of the first order. Using the high field system, second order ducts could be shown and sometimes third order ducts. In the patients, MRCP, using either system, demonstrated all 21 obstructive sites due to tumours or stenoses. Stones were shown in 69% by the low field system and in 88% by the high field system. Conclusion: MRCP can be successfully carried out using the low field system. In the presence of mechanical cholestasis, image quality is adequate for the localisation of stenoses and occlusions, and using an open magnet, is suitable for planning further intervention. (orig.) [de

  10. Pineapple juice labeled with gadolinium: a convenient oral contrast for magnetic resonance cholangiopancreatography

    International Nuclear Information System (INIS)

    Coppens, Emmanuel; Metens, Thierry; Winant, Catherine; Matos, Celso

    2005-01-01

    The aim of our study was to prepare in vitro a pineapple juice (PJ) solution labeled with a minimal gadolinium concentration working as a negative contrast agent in heavily T2-weighted imaging and to assess that solution in vivo as a negative oral contrast agent for magnetic resonance cholangiopancreatography (MRCP). Three PJs were compared in vitro according to their T2. Increasing concentrations of gadolinium (Gd)-DOTA in PJ were assessed in vitro for T2 reduction. Single-shot turbo spin echo T2-weighted MR cholangiopancreatograms were obtained for 35 patients with suspected biliopancreatic duct disease, before and after ingestion of the PJ/Gd-DOTA solution. Signal intensity (SI) measurements of gastroduodenal lumens, pancreatobiliary ducts, and image quality scores were obtained systematically before and after contrast ingestion. The in vitro selected Gd-DOTA concentration in the PJ was 2.76 mmol/l. Ingestion of 180 ml of PJ labeled with 1 ml of Gd-DOTA eliminated efficiently the gastroduodenal SI in MRCP, improving significantly the rates of complete visualization of the pancreatobiliary ducts (P<0.01) and the MRCP image quality scores (P<0.05). All patients easily ingested the contrast solution and found the solution palatable. PJ labeled with gadolinium constituted an efficient and convenient negative oral contrast agent for MRCP. (orig.)

  11. Pineapple juice labeled with gadolinium: a convenient oral contrast for magnetic resonance cholangiopancreatography

    Energy Technology Data Exchange (ETDEWEB)

    Coppens, Emmanuel; Metens, Thierry; Winant, Catherine; Matos, Celso [Hopital Erasme, Universite Libre de Bruxelles, Department of Radiology, Division of Magnetic Resonance, Brussels (Belgium)

    2005-10-01

    The aim of our study was to prepare in vitro a pineapple juice (PJ) solution labeled with a minimal gadolinium concentration working as a negative contrast agent in heavily T2-weighted imaging and to assess that solution in vivo as a negative oral contrast agent for magnetic resonance cholangiopancreatography (MRCP). Three PJs were compared in vitro according to their T2. Increasing concentrations of gadolinium (Gd)-DOTA in PJ were assessed in vitro for T2 reduction. Single-shot turbo spin echo T2-weighted MR cholangiopancreatograms were obtained for 35 patients with suspected biliopancreatic duct disease, before and after ingestion of the PJ/Gd-DOTA solution. Signal intensity (SI) measurements of gastroduodenal lumens, pancreatobiliary ducts, and image quality scores were obtained systematically before and after contrast ingestion. The in vitro selected Gd-DOTA concentration in the PJ was 2.76 mmol/l. Ingestion of 180 ml of PJ labeled with 1 ml of Gd-DOTA eliminated efficiently the gastroduodenal SI in MRCP, improving significantly the rates of complete visualization of the pancreatobiliary ducts (P<0.01) and the MRCP image quality scores (P<0.05). All patients easily ingested the contrast solution and found the solution palatable. PJ labeled with gadolinium constituted an efficient and convenient negative oral contrast agent for MRCP. (orig.)

  12. Cost-effectiveness of endoscopic ultrasonography, magnetic resonance cholangiopancreatography and endoscopic retrograde cholangiopancreatography in patients suspected of pancreaticobiliary disease

    DEFF Research Database (Denmark)

    Ainsworth, A P; Rafaelsen, S R; Wamberg, P A

    2004-01-01

    BACKGROUND: It is not known whether initial endoscopic ultrasonography (EUS) or magnetic resonance cholangiopancreatography (MRCP) is more cost effective than endoscopic retrograde cholangiopancreatography (ERCP). METHODS: A cost-effectiveness analysis of EUS, MRCP and ERCP was performed on 163...

  13. The Impact of Gd-Eob-Dtpa-Enhanced MR Cholangiography in Biliary Diseases: Comparison with T2-Weighted MR Cholangiopancreatography

    Directory of Open Access Journals (Sweden)

    Evrim Özmen

    2016-06-01

    Full Text Available Background: Contrast enhanced magnetic resonance cholangiography is a novel technique and promising method in demonstrating biliary tree anatomy and evaluating biliary disorders. However, to date, there are a limited number of studies that have focused on the impact of this technique. Aims: We aimed to evaluate the additional role of contrast enhanced MR cholangiography (MRC and compare contrast enhanced MRC with T2-weighted (w magnetic resonance cholangiopancreatography (MRCP in the diagnosis of biliary disorders. Study Design: Diagnostic accuracy study. Methods: The T2w-MRCP and contrast enhanced MRC sequences of 31 patients whose gold standard test results were available were scored visually for the existence of pathological findings with regard to any of the biliary diseases. Gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA was used as the contrast agent. The correlation values were determined according to the statistical analysis made from those scores and the sensitivity, specificity and accuracy values of each sequence were detected as well. Results: We detected that the correlation values with gold standard methods of contrast enhanced MRC sequences were significantly higher than the ones of T2w-MRCP sequences. The correlation ratios of T2w-MRCP sequences were between 26 and 34%, while those for contrast enhanced MRC sequences were between 81 and 83% for the first reader and the correlation ratios of T2w-MRCP sequences were between 10 and 61%, whereas those of contrast enhanced MRC were between 79 and 81% for the second reader The mean sensitivity, specificity and accuracy values of T2w-MRCP sequences were 14.3-42.5%, 85-89.2% and 59.3-72.5%, respectively, while the mean sensitivity, specificity and accuracy values of contrast enhanced MRC sequences were 100%, 86.7% and 93.2-93.3%, respectively. Conclusion: We suggest that obtaining of contrast enhanced MRC sequences in addition to the T2w-MRCP can be useful in

  14. Imaging features of portal biliopathy: Frequency of involvement patterns with emphasis on MRCP

    Energy Technology Data Exchange (ETDEWEB)

    Ozkavukcu, Esra [Ankara University School of Medicine, Department of Radiology (Turkey)], E-mail: eozkavukcu@gmail.com; Erden, Ayse; Erden, Ilhan [Ankara University School of Medicine, Department of Radiology (Turkey)

    2009-07-15

    Purpose: To investigate the imaging features of portal biliopathy with emphasis on MR cholangiopancreatography (MRCP). The ancillary vascular findings of portal biliopathy were also evaluated by accompanying MR portography, dynamic contrast-enhanced (CE) CT, and dynamic CE MRI studies. Materials and methods: Sixteen patients with portal cavernoma were included in the study. Patients had undergone MRCP (n = 16) studies accompanied by MR portography (n = 13), dynamic CE CT (n = 3) or dynamic CE MRI (n = 2) of the liver. Two patients had undergone both dynamic CE CT and dynamic CE MRI. Two radiologists evaluated all the examinations together, retrospectively. MRCP images were analyzed for the presence of biliary stenosis, upstream (prestenotic) dilatation, wavy appearance of the bile ducts, angulation of the common bile duct (CBD), and choledocholithiasis. MR portography, dynamic CE CT and dynamic CE MRI studies were evaluated for the existence of portal cavernomas, and the presence of gall bladder/choledochal varices. Results: All patients had signs of portal biliopathy on MRCP. Frequencies of the biliary findings on MRCP were as follows: biliary stenosis, 93.7%; upstream dilatation, 68.7%; wavy appearance of the biliary tree, 87.5%; angulation of the CBD, 75%. None of the patients had choledocholithiasis. Frequencies of the ancillary vascular findings detected on CE studies were as follows: gall bladder varices, 100%, choledochal varices, 93.7%. Conclusion: MRCP features of portal biliopathy in order to their frequencies were as follows: biliary stenosis, wavy appearance of the bile ducts, angulation of the CBD, and upstream dilatation of the bile ducts.

  15. MR cholangiopancreatography: prospective comparison of a breath-hold 2D projection technique with diagnostic ERCP

    International Nuclear Information System (INIS)

    Lomas, D.J.; Bearcroft, P.W.P.; Gimson, A.E.

    1999-01-01

    The aim of this study was to compare prospectively a breath-hold projection magnetic resonance cholangiopancreatography (MRCP) technique with diagnostic endoscopic retrograde cholangiopancreatography (ERCP). Seventy-six patients with suspected strictures or choledocholithiasis were referred for MRCP and subsequent ERCP examination, which were performed within 4 h of each other. The MRCP technique was performed using fat-suppressed rapid acquisition with relaxation enhancement (RARE) projection images obtained in standardised planes with additional targeted projections as required by the supervising radiologist. Two radiologists (in consensus) assessed the MRCP results prospectively and independently for the presence of bile duct calculi, strictures, non-specific biliary dilatation and pancreatic duct dilatation, and recorded a single primary diagnosis. The ERCP was assessed prospectively and independently by a single endoscopist and used as a gold standard for comparison with MRCP. Diagnostic agreement was assessed by the Kappa statistic. The MRCP technique failed in two patients and ERCP in five. In the remaining 69 referrals ERCP demonstrated normal findings in 23 cases, strictures in 19 cases, choledocholithiasis in 9 cases, non-specific biliary dilatation in 14 cases and chronic pancreatitis in 4 cases. The MRCP technique correctly demonstrated 22 of 23 normal cases, 19 strictures with one false positive (sensitivity 100 %, specificity 98 %), all 9 cases of choledocholithiasis with two false positives (sensitivity 100 %, specificity 97 %), 12 of 14 cases of non-specific biliary dilatation and only 1 of 4 cases of chronic pancreatitis. There was overall good agreement for diagnosis based on a kappa value of 0.88. Breath-hold projection MRCP can provide non-invasively comparable diagnostic information to diagnostic ERCP for suspected choledocholithiasis and biliary strictures and may allow more selective use of therapeutic ERCP. (orig.)

  16. Pancreatic duct abnormalities in focal autoimmune pancreatitis: MR/MRCP imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Negrelli, Riccardo; Manfredi, Riccardo; Pedrinolla, Beatrice; Boninsegna, Enrico; Ventriglia, Anna; Mehrabi, Sara; Pozzi Mucelli, Roberto [G.B. Rossi University Hospital, University of Verona, Department of Radiology, Verona (Italy); Frulloni, Luca [Universita di Verona, Department of Gastroenterology, Policlinico G.B. Rossi, Verona (Italy)

    2014-08-09

    To evaluate the magnetic resonance (MR) imaging-MR cholangiopancreatographic (MRCP) findings of focal forms of autoimmune pancreatitis (AIP) to describe ductal involvement at diagnosis. MR examinations of 123 patients affected by AIP were analysed. We included 26 patients who satisfied International Consensus Diagnostic Criteria and were suffering from focal AIP. Image analysis included: site of parenchymal enlargement, main pancreatic duct (MPD) diameter, MPD stenosis, stricture length, presence of upstream dilation within the stricture, signal intensity, and pancreatic enhancement. Signal intensity abnormalities were localized in the head in 10/26 (38.5 %) and in the body-tail in 16/26 (61.5 %) patients. MRCP showed a single MPD stenosis in 12/26 (46.1 %) and multiple MPD stenosis in 14/26 (53.8 %) patients, without a dilation of the upstream MPD (mean: 3.83 mm). Lesions showed hypointensity on T1-weighted images in all patients, and hyperintensity on T2-weighted images in 22/26 (84.6 %) patients. The affected parenchyma was hypovascular during the arterial phase in 25/26 (96.2 %) patients with contrast retention. MR-MRCP are effective techniques for the diagnosis of AIP showing the loss of the physiological lobulation and the typical contrastographic appearance. The presence of multiple, long stenoses without an upstream MPD dilation at MRCP suggests the diagnosis of AIP, and can be useful in differential diagnosis of pancreatic adenocarcinoma. (orig.)

  17. Diagnostic accuracy of MRCP in choledocholithiasis

    International Nuclear Information System (INIS)

    Guarise, Alessandro; Mainardi, Paride; Baltieri, Susanna; Faccioli, Niccolo'

    2005-01-01

    Purpose: To evaluate the accuracy of MRCP in diagnosing choledocholithiasis considering Endoscopic Retrograde Cholangiopancreatography (ERCP) as the gold standard. To compare the results achieved during the first two years of use (1999-2000) of Magnetic Resonance Cholangiopancreatography (MRCP) in patients with suspected choledocholithiasis with those achieved during the following two years (2001-2002) in order to establish the repeatability and objectivity of MRCP results. Materials and methods: One hundred and seventy consecutive patients underwent MRCP followed by ERCP within 72 h. In 22/170 (13%) patients ERCP was unsuccessful for different reasons. MRCP was performed using a 1.5 T magnet with both multi-slice HASTE sequences and thick-slice projection technique. Choledocholithiasis was diagnosed in the presence of signal void images in the dependent portion of the duct surrounded by hyperintense bile and detected at least in two projections. The MRCP results, read independently from the ERCP results, were compared in two different and subsequent periods. Results: ERCP confirmed choledocholithiasis in 87 patients. In these cases the results of MRCP were the following: 78 true positives, 53 true negatives, 7 false positives, and 9 false negatives. The sensitivity, specificity and accuracy were 90%, 88% and 89%, respectively. After the exclusion of stones with diameters smaller than 6 mm, the sensitivity, specificity and accuracy were 100%, 99% and 99%, respectively. MRCP accuracy was related to the size of the stones. There was no significant statistical difference between the results obtained in the first two-year period and those obtained in the second period. Conclusions: MRCP i sufficiently accurate to replace ERCP in patients with suspected choledocholithiasis. The results are related to the size of stones. The use of well-defined radiological signs allows good diagnostic accuracy independent of the learning curve [it

  18. The role of magnetic resonance cholangiopancreatography and ...

    African Journals Online (AJOL)

    ) is accepted as the gold standard, there is a place for magnetic resonance cholangiopancreatography (MRCP) and diffusion-weighted imaging (DWI) in the diagnosis of obstructive biliary disorders. Aim: To compare the findings of MRCP with ...

  19. Evaluation of the use of blueberry juice in magnetic resonance cholangiopancreatography

    International Nuclear Information System (INIS)

    Tanaka, Yasunori; Fujita, Osamu; Yuuki, Masako; Matsuoka, Takae; Yamamoto, Kazuhiro; Shimizu, Tadahumi; Narabayashi, Isamu; Nishio, Seiichi

    1998-01-01

    We evaluated the use of blueberry juice (BJ), which is rich in manganese, as an oral negative contrast agent for magnetic resonance cholangiopancreatography (MRCP) and compared the findings thus obtained with corresponding findings for ferric ammonium citrate solution (FerriSeltz; FS). The optimum concentrations for the two oral contrast agents were determined by a phantom examination. Precontrast and postcontrast MRCP images were obtained in 26 patients and 4 volunteers using BJ and in 30 patients using FS. The pulse sequence applied for MRCP was a single shot fast spin-echo (ssfse) with an echo time of 950 to 1300 ms. In several cases, multislice ssfse with 90 ms echo time was conducted using both BJ and FS. Additionally, 8 volunteers who had recently consumed food or liquids underwent precontrast and postcontrast MRCP using BJ. BJ and FS eliminated the high signal intensity of gastrointestinal fluids which degrade MRCP images. In the multislice ssfse images with 90 ms. Echo time, BJ reduced the intragastrointestinal high intensity signal, but FS did not. In all volunteers whose stomachs were filled with food and/or water, intragastrointestinal high intensity signal was eliminated with use of BJ. We concluded that BJ is very useful as an MRCP negative contrast agent. (author)

  20. CT vs. MRCP in choledocholithiasis jaundice.

    Science.gov (United States)

    Petrescu, I; Bratu, A M; Petrescu, S; Popa, B V; Cristian, D; Burcos, T

    2015-01-01

    Obstructive jaundice can raise problems to diagnostic imaging. The radiologist must choose the most appropriate examination that delivers the most important diagnostic information because the differences between a lithiasic obstruction and a tumoral one are vital. This information helps the surgeon speed up the process of decision-making, because the treatment may be very different in relation to the nature of the obstruction. This study tries to demonstrate the diagnostic accuracy of computed tomography (CT) and magnetic resonance cholangiopancreatography (MRCP) in detecting the obstacle in the common bile duct (CBD) and the possibility of establishing the lithiasic nature of the obstruction. A retrospective analysis was analyzed during an interval of 18 months that included jaundice patients admitted in the General Surgery Department of "Coltea" Clinical Hospital. They were examined by CT scanning and by MRCP, being suspected of choledocholithiasis. 63 patients were included in the study, 34 females and 29 males. 33 CT scans and 30 MRCP exams were performed. CT scan is useful in detecting residual or iterative choledocholithiasis in patients after cholecystectomy, contrast enhanced CT (CECT), being able to differentiate between lithiasic and non-lithiasic obstruction. MRCP delivers important anatomic details of the biliary tree; it is superior to CT in diagnosing the hepatocholedochal lithiasis; MRCP tends to replace endoscopic retrograde cholangiopancreatography (ERCP)--the diagnostic "gold standard" reducing the number of unnecessary invasive diagnostic procedures.

  1. Sensitivity and Specificity of Magnetic Resonance Cholangiopancreatography versus Endoscopic Ultrasonography against Endoscopic Retrograde Cholangiopancreatography in Diagnosing Choledocholithiasis: The Indonesian Experience

    Directory of Open Access Journals (Sweden)

    Dadang Makmun

    2017-09-01

    Full Text Available Background/Aims Biliary stone disease is one of the most common conditions leading to hospitalization. In addition to endoscopic retrograde cholangiopancreatography (ERCP, endoscopic ultrasonography (EUS and magnetic resonance cholangiopancreatography (MRCP are required in diagnosing choledocholithiasis. This study aimed to compare the sensitivity and specificity of EUS and MRCP against ERCP in diagnosing choledocholithiasis. Methods This retrospective study was conducted after prospective collection of data involving 62 suspected choledocholithiasis patients who underwent ERCP from June 2013 to August 2014. Patients were divided into two groups. The first group (31 patients underwent EUS and the second group (31 patients underwent MRCP. Then, ERCP was performed in both groups. Sensitivity, specificity, and diagnostic accuracy of EUS and MRCP were determined by comparing them to ERCP, which is the gold standard. Results The male to female ratio was 3:2. The mean ages were 47.25 years in the first group and 52.9 years in the second group. Sensitivity, specificity, accuracy, positive predictive value, and negative predictive value for EUS were 96%, 57%, 87%, 88%, and 80% respectively, and for MRCP were 81%, 40%, 68%, 74%, and 50%, respectively. Conclusions EUS is a better diagnostic tool than MRCP for diagnosing choledocholithiasis.

  2. Magnetic resonance cholangiopancreatography. The fine art of bilio-pancreatic imaging.

    Science.gov (United States)

    Adamek, H E; Breer, H; Layer, G; Riemann, J F

    2002-01-01

    With the introduction of endoscopic retrograde cholangio-pancreatography in the early 1970s, gastroenterologists have a lot of diagnostic options in the biliopancreatic system to their disposal. Meanwhile, magnetic resonance cholangiopancreatography (MRCP) has become a competitive replacement for diagnostic ERCP with the advantage of avoiding complications related to endoscopic techniques. Mounting evidence suggests that both MRCP and MRI (magnetic resonance imaging) have a profound influence of diagnostic algorithms in a variety of hepatobiliary and pancreatic diseases. Copyright 2002 S. Karger AG, Basel and IAP

  3. Focal Pancreatitis Mimicking Pancreatic Mass: Magnetic Resonance Imaging (MRI)/Magnetic Resonance Cholangiopancreatography (MRCP) Findings Including Diffusion-Weighted MRI

    International Nuclear Information System (INIS)

    Momtahen, A.J.; Balci, N.C.; Alkaade, S.; Akduman, E.I.; Burton, F.R.

    2008-01-01

    Background: Focal pancreatitis (FP) is a confined inflammation that mimics a pancreatic mass. Its imaging diagnosis is important to avoid unnecessary procedures. Purpose: To describe the spectrum of magnetic resonance imaging (MRI)/magnetic resonance cholangiopancreatography (MRCP) and diffusion-weighted MRI (DWI) findings of focal pancreatitis mimicking pancreatic masses. Material and Methods: Findings of MRI/MRCP including DWI with a b value of 0 and 600 s/mm2 in 14 patients with pancreatic masses on MRI were retrospectively reviewed and compared to normal pancreas in 14 patients as a control group. Results: FP revealed hypointense signal intensity (SI) (3/14), hypo- to isointense SI (7/14), or isointense SI (4/14) on T1-weighted images, and hypointense SI (1/14), isointense SI (5/14), iso- to hyperintense SI (7/14), or hyperintense SI (1/14) on T2-weighted images compared to remaining pancreas (RP). MRCP images revealed dilatation of the common bile duct (CBD) and main pancreatic duct (MPD) (5/14), dilatation of the MPD only (3/14), dilatation of the CBD only (3/14), and normal MPD and CBD (3/14). Both FP and RP revealed three types of time-signal intensity curves: 1) rapid rise to a peak, with a rapid decline (FP=2, RP=4), 2) slow rise to a peak, followed by a slow decline (FP=5, RP=4), and 3) slower rise to a peak, with a slow decline or plateau (FP=7, RP=6). Mean apparent diffusion coefficient (ADC) values for FP and RP were 2.09±0.18 and 2.03±0.2x10 -3 mm 2 /s, respectively. ADC values of FP and RP revealed no significant difference. Conclusion: The spectrum of imaging findings of focal pancreatitis on MRI/MRCP including DWI was described. Findings of FP were not distinctive as compared to the remaining pancreas

  4. Automatic gallbladder segmentation using combined 2D and 3D shape features to perform volumetric analysis in native and secretin-enhanced MRCP sequences.

    Science.gov (United States)

    Gloger, Oliver; Bülow, Robin; Tönnies, Klaus; Völzke, Henry

    2017-11-24

    We aimed to develop the first fully automated 3D gallbladder segmentation approach to perform volumetric analysis in volume data of magnetic resonance (MR) cholangiopancreatography (MRCP) sequences. Volumetric gallbladder analysis is performed for non-contrast-enhanced and secretin-enhanced MRCP sequences. Native and secretin-enhanced MRCP volume data were produced with a 1.5-T MR system. Images of coronal maximum intensity projections (MIP) are used to automatically compute 2D characteristic shape features of the gallbladder in the MIP images. A gallbladder shape space is generated to derive 3D gallbladder shape features, which are then combined with 2D gallbladder shape features in a support vector machine approach to detect gallbladder regions in MRCP volume data. A region-based level set approach is used for fine segmentation. Volumetric analysis is performed for both sequences to calculate gallbladder volume differences between both sequences. The approach presented achieves segmentation results with mean Dice coefficients of 0.917 in non-contrast-enhanced sequences and 0.904 in secretin-enhanced sequences. This is the first approach developed to detect and segment gallbladders in MR-based volume data automatically in both sequences. It can be used to perform gallbladder volume determination in epidemiological studies and to detect abnormal gallbladder volumes or shapes. The positive volume differences between both sequences may indicate the quantity of the pancreatobiliary reflux.

  5. Pancreatic changes in patients with primary sclerosing cholangitis: MR cholangiopancreatography and MRI findings

    International Nuclear Information System (INIS)

    Ozkavukcu, Esra; Erden, Ayse; Erden, Ilhan

    2009-01-01

    Purpose: To evaluate the possible pancreatic changes and their frequencies in patients with primary sclerosing cholangitis (PSC) on MR cholangiopancreatography (MRCP), and conventional abdominal MRI. Materials and Methods: Patient group consisted of 29 PSC (13 male, 16 female) cases, whereas cohort 1 consisted of 12 female patients with primary biliary cirrhosis, and cohort 2 consisted of 17 patients (6 male, 11 female) with non-immune chronic liver disease. Two radiologists retrospectively evaluated the MR examinations paying special attention to the pancreatic size (atrophy or enlargement), T1- and T2-signal intensity of the pancreas, focal pancreatic lesion, capsule-like rim, peripancreatic edema or fluid, fascial thickening, and pancreatic ducts (dilatation or narrowing). The results are expressed as percentages. Three groups were compared using Pearson chi-square test for each feature. However, only p-value for 'dilatation of the pancreatic duct' was determined, whereas p-value could not be calculated because of the insufficient number of subjects/sequences for the other features. Results: Twelve PSC patients (41.3%) had pancreatic abnormalities. The most common pancreatic changes in PSC patients were decreased T1-signal intensity (44%) and dilatation of the pancreatic duct (13.8%), respectively. Increased T2-signal intensity was also shown in 2 PSC patients (6.9%). Conclusion: Even PSC patients without any sign of pancreatitis, can show MR changes in the pancreatic parenchyma or the pancreatic duct. The etiologies of these changes, and whether they are unique to PSC, are still controversial. Histopathological studies bringing light to these pancreatic changes are needed.

  6. MR imaging and MR cholangiopancreatography in the preoperative evaluation of hilar cholangiocarcinoma: correlation with surgical and pathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Masselli, Gabriele; Gualdi, Gianfranco [Umberto I Hospital-La Sapienza University Rome, Department of Radiology, Rome (Italy); Manfredi, Riccardo [University of Verona, Department of Radiology, Verona (Italy); Vecchioli, Amorino [A. Gemelli Hospital-University of Sacred Heart, Department of Radiology, Rome (Italy)

    2008-10-15

    The primary aim was to evaluate delayed contrast-enhanced MRI in depicting perineural spread of hilar cholangiocarcinoma (CCC) and consequently to determine the capability of MRI/MRCP for staging CCC. Fifteen patients that underwent MRI/MRCP and surgical treatment were retrospectively included. Two radiologists evaluated MR images to assess delayed periductal enhancement, extent of bile duct stenosis, liver parenchymal and vascular involvement and presence of liver atrophy. An agreement between delayed enhancement of the bile duct walls and perineural neoplastic spread showed a very good correlation factor (0.93). The overall accuracy in detecting biliary neoplastic invasion was higher for delayed T1-weighted images (93.3%) than for the MRCP images (80%), and T1-delayed image increased the MR accuracy in assessing the neoplastic resectability (p < 0.05). MRI correctly predicted vascular involvement in 73% and liver involvement in 80% of the cases. The number of overall correctly assessed patients with regard to resectability was 11 true positive, 1 false positive and 3 true negative. The combination of MRI/MRCP is a reliable diagnostic method for staging hilar cholangiocarcinomas. Delayed periductal enhancement is accurate in the evaluation of neoplastic perineural spread, and it can improve diagnostic accuracy to identify resectable and unresectable tumours. (orig.)

  7. Utility of single shot fast spin echo technique in evaluating pancreaticobiliary diseases: T2-weighted image and magnetic resonance cholangiopancreatography

    International Nuclear Information System (INIS)

    Choi, Byoung Wook; Kim, Myeong Jin; Chung, Jae Bok; Ko, Heung Kyu; Kim, Dong Joon; Kim, Joo Hee; Chung, Jae Joon; Yoo, Hyung Sik; Lee, Jong Tae

    1999-01-01

    To evaluate the accuracy of T2-weighted imaging an MR cholangiopancreatography using the single shot fast spin-echo technique for evaluating pancreaticobiliary disease. Between March and July 1997, axial and coronal T2-weighted images(TE: 80-200 msec) and MR cholangiopancreatograms (TE: 800-1200 msec) were obtained in two ways [single slab (thickness: 30-50 mm) and multislice acquisition under chemical fat saturation] using SSFSE pulse sequencing in 131 cases of suspected pancreati-cobiliary disease. The accuracy of SSFSE MR imaging was assessed in 89 lesions of 74 patients [male, 48; female, 26; age range, 30-86 (mean, 59) years] confirmed surgicopathologically (50 lesions in 39 patients) and clinically (39 lesions in 35 patients). Two radiologists reviewed the MR images and diagnosis was determined by consensus. Correct diagnosis was confirmed in 84 of 89 lesions (94%). Seven lesions were falsely interpreted, false positive and false negative results accounting for two and five cases, respectively. Two pancreatic cancers were misdiagnosed as pancreatitis and a cancer of the proximal common bile duct(CBD) was interpreted as a distal CBD cancer. The sensitivity of SSFSE MR imaging for malignancy was 93 %. One CBD stone revealed by endoscopic retrograde cholangiopancreatography (ERCP) was not detected on MR images. In contrast, a stone in the CBD seen on MR images was not apparent on subsequent ERCP. Sensitivity and specificity for calculous disease were 96% and 99.7%, respectively. A benign stricture of the ampulla of Vater was falsely interpreted as normal, and correct diagnosis was possible in two falsely diagnosed cases when MR images were reviewed retrospectively. The combination of T2-weighted and cholangiographic images using SSFSE is an accurate method for diagnosing pancreatcobiliary diseases

  8. A prospective pilot study: Can the biliary tree be visualized in children younger than 3 months on Magnetic Resonance Cholangiopancreatography?

    Energy Technology Data Exchange (ETDEWEB)

    Siles, Pascale [La Timone Children' s Hospital, Department of Radiology, Marseille (France); Aschero, Audrey; Gorincour, Guillaume; Bourliere-Najean, Brigitte; Petit, Philippe [La Timone Children' s Hospital, Department of Pediatric Radiology, Marseille (France); Roquelaure, Bertrand [La Timone Children' s Hospital, Department of Pediatrics, Marseille (France); Delarue, Arnauld [La Timone Children' s Hospital, Department of Pediatric Surgery, Marseille (France)

    2014-09-15

    Magnetic resonance cholangiopancreatography (MRCP) could aid in the diagnosis of biliary atresia, a hepatic pathology with thin, irregular or interrupted biliary ducts. There is little published evidence of MRCP appearances in normal neonates and young infants. To assess the use of MR cholangiopancreatography in visualizing the biliary tree in neonates and infants younger than 3 months with no hepatobiliary disorder, and to assess this visibility in relationship to the child's age, weight, and sedation and fasting states. Between December 2008 and October 2010 our department performed MRI of the brain, orbits and face on 16 full-term neonates and infants. Each child was younger than 3 months (90 days) and without any hepatobiliary disorders. The children were scanned with a respiratory-gated 0.54 x 0.51 x 0.4-mm{sup 3} 3-D MRCP sequence. We used a reading grid to assess subjectively the visibility of the extrahepatic bile ducts along with extrahepatic bile duct confluence. The visibility of the extrahepatic bile duct confluence was assessed against age, weight, and sedation and fasting states. The extrahepatic bile duct confluence was seen in 10 children out of 16 (62.5%). In the neonate sub-group (corrected age younger than 30 days), the MRCP was technically workable and the extrahepatic bile duct confluence was seen in four cases out of eight (50%). This visualization was up to 75% in the subgroup older than 30 days. However, statistically there was no significant difference in visibility of the extrahepatic bile duct confluence in relationship to age, weight or MRCP performance conditions (feeding, fasting or sedation). The complete normal biliary system (extrahepatic bile duct confluence included) is not consistently visualized in infants younger than 3 months old on non-enhanced MRCP. Thus the use of MRCP to exclude a diagnosis of biliary atresia is compromised at optimal time of surgery. (orig.)

  9. A prospective pilot study: Can the biliary tree be visualized in children younger than 3 months on Magnetic Resonance Cholangiopancreatography?

    International Nuclear Information System (INIS)

    Siles, Pascale; Aschero, Audrey; Gorincour, Guillaume; Bourliere-Najean, Brigitte; Petit, Philippe; Roquelaure, Bertrand; Delarue, Arnauld

    2014-01-01

    Magnetic resonance cholangiopancreatography (MRCP) could aid in the diagnosis of biliary atresia, a hepatic pathology with thin, irregular or interrupted biliary ducts. There is little published evidence of MRCP appearances in normal neonates and young infants. To assess the use of MR cholangiopancreatography in visualizing the biliary tree in neonates and infants younger than 3 months with no hepatobiliary disorder, and to assess this visibility in relationship to the child's age, weight, and sedation and fasting states. Between December 2008 and October 2010 our department performed MRI of the brain, orbits and face on 16 full-term neonates and infants. Each child was younger than 3 months (90 days) and without any hepatobiliary disorders. The children were scanned with a respiratory-gated 0.54 x 0.51 x 0.4-mm 3 3-D MRCP sequence. We used a reading grid to assess subjectively the visibility of the extrahepatic bile ducts along with extrahepatic bile duct confluence. The visibility of the extrahepatic bile duct confluence was assessed against age, weight, and sedation and fasting states. The extrahepatic bile duct confluence was seen in 10 children out of 16 (62.5%). In the neonate sub-group (corrected age younger than 30 days), the MRCP was technically workable and the extrahepatic bile duct confluence was seen in four cases out of eight (50%). This visualization was up to 75% in the subgroup older than 30 days. However, statistically there was no significant difference in visibility of the extrahepatic bile duct confluence in relationship to age, weight or MRCP performance conditions (feeding, fasting or sedation). The complete normal biliary system (extrahepatic bile duct confluence included) is not consistently visualized in infants younger than 3 months old on non-enhanced MRCP. Thus the use of MRCP to exclude a diagnosis of biliary atresia is compromised at optimal time of surgery. (orig.)

  10. Clinical significance of magnetic resonance cholangiopancreatography for the diagnosis of cystic tumor of the pancreas compared with endoscopic retrograde cholangiopancreatography and computed tomography

    International Nuclear Information System (INIS)

    Mera, Kiyomi; Tajiri, Hisao; Muto, Manabu

    1999-01-01

    Cystic tumor of the pancreas has been investigated by a variety of imaging techniques. Magnetic resonance cholangiopancreatography (MRCP) is being widely used as a non-invasive diagnostic modality for investigation of the biliary tree and pancreatic duct system. The purpose of this study was to compare MRCP images with those of endoscopic retrograde cholangiopancreatography (ERCP) and computed tomography (CT) in order to clarify the diagnostic efficacy of MRCP for cystic tumor of the pancreas. We retrospectively studied 15 patients with cystic tumor of the pancreas that had been surgically resected and histopathologically confirmed. There were five cases of intraductal papillary adenocarcinoma, five of intraductal papillary adenoma, two of serous cyst adenoma, two of retention cyst associated with invasive ductal adenocarcinoma and one of solid cystic tumor. In all cases MRCP correctly identified the main pancreatic duct (MPD) and showed the entire cystic tumor and the communication between the tumor and the MPD. On the other hand, the detection rate by ERCP of the cystic tumor and the communication between the cystic tumor and the MPD was only 60%. Although the detection rates by CT for the septum and solid components inside the cystic tumor were 100 and 90.0%, respectively, those of MRCP for each were 58.3 and 20.0%. MRCP is capable of providing diagnostic information superior to ERCP for the diagnosis of cystic tumor of the pancreas. Although MRCP may provide complementary information about the whole lesion of interest, the characteristic internal features of cystic tumor of the pancreas should be carefully diagnosed in combination with CT. (author)

  11. Utility of MRCP in clinical decision making of suspected choledocholithiasis: An institutional analysis and literature review.

    Science.gov (United States)

    Badger, Wesley R; Borgert, Andrew J; Kallies, Kara J; Kothari, Shanu N

    2017-08-01

    The ideal treatment algorithm for suspected choledocholithiasis is not yet well defined. Imaging options include magnetic resonance cholangiopancreatography (MRCP), endoscopic retrograde cholangiopancreatography (ERCP), and intraoperative cholangiogram (IOC). MRCP is diagnostic, while the other two modalities can also be therapeutic. Each of these modalities for diagnosis and treatment carries its own set of risks, benefits, and institutional costs. We hypothesized that there would be a significant difference between the biochemical profiles and characteristics of patients who undergo ERCP vs. MRCP vs. operative intervention as the initial choice of treatment/imaging modality. We performed a retrospective review of the electronic medical records for all patients with a coded diagnosis of choledocholithiasis from 2011 to 2014. The initial diagnostic modality was assessed for each hospital encounter. The statistical characteristics of MRCP as compared to fluoroscopic imaging of the biliary tree (ERCP, IOC) were analyzed. Overall, 527 hospital encounters were identified. Initial intervention included ERCP in 63%, MRCP in 12%, and cholecystectomy in 25% of patients. Patients undergoing cholecystectomy first, compared to MRCP or ERCP, tended to have lower values for alkaline phosphatase (P utility in this patient population should be questioned. Further research is needed to better define the pretest characteristics which would predict which patients do not need further intervention after MRCP as well as defining the most cost-effective strategy. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Secretin-stimulated MR cholangio-pancreatography in the evaluation of asymptomatic patients with non-specific pancreatic hyperenzymemia

    Energy Technology Data Exchange (ETDEWEB)

    Donati, Francescamaria, E-mail: fra.donati@katamail.co [2nd Department of Radiology, Pisa University-Hospital, Via Paradisa 2, I-56124 Pisa (Italy); Boraschi, Piero; Gigoni, Roberto; Salemi, Simonetta [2nd Department of Radiology, Pisa University-Hospital, Via Paradisa 2, I-56124 Pisa (Italy); Faggioni, Lorenzo; Bertucci, Cristina; Cecchi, Claudia; Bartolozzi, Carlo [Diagnostic and Interventional Radiology, University of Pisa, Via Rome 67, I-56126 Pisa (Italy); Falaschi, Fabio [2nd Department of Radiology, Pisa University-Hospital, Via Paradisa 2, I-56124 Pisa (Italy)

    2010-08-15

    Purpose: To assess the diagnostic value of secretin-stimulated MRCP (SS-MRCP) compared with conventional MRCP in asymptomatic patients with mild elevations of pancreatic enzymes. Materials and methods: Eighty asymptomatic patients with pancreatic hyperenzymemia underwent MR imaging at 1.5 T-device (Signa EXCITE, GE Healthcare). After the acquisition of axial T1w,T2w sequences, and conventional MRCP, SS-MRCP was performed using a single-slice coronal breath-hold, thick-slab, SSFSE T2w sequence, repeated every 30 s up to 15 min following intravenous injection of secretin (Secrelux, Sanochemia). Results: On the basis of the standards of reference, our final diagnoses were: negative findings (n = 23), pancreas divisum (n = 22), mild chronic pancreatitis (n = 14), inflammatory ampullary stenosis (n = 3), juxtapapillary duodenal diverticulum (n = 1), small cystic lesions (<1 cm) (n = 22; 5/22 cases associated with pancreas divisum). The image quality of SS-MRCP was significantly higher than that of conventional MRCP (p < 0.0001). Standards of reference did not differ significantly from of SS-MRCP findings (p = 0.5), while was statistically different from those of conventional MRCP (p < 0.0001). A significant difference was found between conventional MRCP and SS-MRCP findings (p < 0.0001). Conclusion: In asymptomatic patients with non-specific pancreatic hyperenzymemia SS-MRCP may represent the best non-invasive diagnostic technique, since it gives morphological and functional information.

  13. Cholangiopancreatography for magnetic resonance (CPRM), using T2 - TSE technique and reconstructions 3D - Experience with 38 patients

    International Nuclear Information System (INIS)

    Esguerra Espinosa, Monica

    1997-01-01

    Magnetic resonance cholangiopancreatography (MRCP) is a non-invasive diagnostic method for the study of the biliary system that does not require contrast media or exposure to ionising radiation. Thirty-eight patients were studied; five apparently healthy ones only with MRCP; and 33 with possible biliary tract pathology, most of which had both endoscopes retrograde cholangiopancreatogaphy (ERCP) and MRCP: All MRCP's were performed with a 3D - TSE sequence with T2 - weighting, using coronal thin contiguous slices and reconstructions with maximal intensity projections (MIP) on different planes. MRCP allows an excellent anatomic depiction of the biliary tree and pancreatic duct

  14. Noninvasive study of anatomic variations of the bile and pancreatic duct using magnetic resonance cholangiopancreatography

    International Nuclear Information System (INIS)

    Fernandez, E.; Falco, J.; Campo, R.; Martin, J.; Brullet, E.; Espinos, J.

    1999-01-01

    To identify anatomic variations of the bile duct and pancreatic duct and papillary anomalies by means of magnetic resonance cholangiopancreatography (MRCP) and determine their correlation with endoscopic retrograde cholangiopancreatography (ERCP) findings. Eighty-five patients were selected by means of a prospective study comparing MRCP and ERCP. Coronal and axial HASTE images and coronal and oblique coronal RARE images were acquired in all the patients. Four of the studies (6%) were excluded because of poor technical quality. Anatomic variations were observed in 26 cases (30.5%), including trifurcation (n=7; 27%), right hepatic duct draining into left hepatic duct (n=2, 7.7%), right hepatic duct draining into common bile duct (n=4; 15.4%), extrahepatic confluence (n=2; 7.7%), medial cystic duct (n=2; 7.7%), parallel cystic duct (n=3; 11.5%), juxtapapillary duodenal diverticulum (n=3; 11.5%) and pancreas divisum (n=3; 11.5%). A good correlation was observed between the MRCP and ERCP findings. The introduction of MRCP into the noninvasive study of biliary disease may be useful in the detection of anatomic variations relevant to laparoscopic surgery and other endoscopic and interventional techniques. (Author) 11 refs

  15. Usefulness of MR cholangiopancreatography after intravenous morphine administration

    International Nuclear Information System (INIS)

    Lee, So Jung; Ko, Ji Ho; Cho, Young Duk; Jung, Mi Hee; Yoon, Byung Chull

    2007-01-01

    We wanted to assess the usefulness of MRCP after intravenous morphine administration in the evaluation of the hepatopancreatic pancreatico-biliary ductal system. We studied 15 patients who were suspected of having disease of hepatopancreatic ductal system and they did not have any obstructive lesion on ultrasonography and/or CT. MRCP was acquired before and after morphine administration (0.04 mg/kg, intravenously). Three radiologists scored the quality of the images of the anatomic structures in the hepatopancreatic ductal system. We directly compared the quality of the images obtained with using the two methods and the improvement of the artifacts by pulsatile vascular compression. The MRCP images obtained after intravenous morphine administration were better than those obtained before morphine administration for visualizing the hepatopancreatic ductal system. On direct comparison, the MRCP images obtained after morphine administration were better in 12 cases, equivocal in two cases, and the images before morphine administration were better in only one case. In three patients, MRCP before morphine injection showed signal loss at the duct across the pulsatile hepatic artery. In two of three patients, MRCP after morphine injection showed no signal loss in this ductal area. MRCP after intravenous morphine administration enables physicians to see the hepatopancreatic ductal system significantly better and the artifacts caused by pulsation of the hepatic artery can be avoided

  16. The role of MRI in evaluation of acute pancreatitis

    International Nuclear Information System (INIS)

    Baba, Maiko; Munechika, Horotsugu

    2003-01-01

    The purpose of this study is to assess the role of MRI in acute pancreatitis. The findings of MPD (main pancreatic duct) and CBD (common bile duct) on MR cholangiopancreatography (MRCP) images were retrospectively reviewed in 60 patients with acute pancreatitis. The patients were divided into two groups; severe and mild pancreatitis, according to the criteria of Japanese group of investigation for pancreatic diseases. T2 weighed MR images were compared with contrast-enhanced CT images for evaluation of severity of the disease. MRCP images were also compared with endoscopic retrograde cholangiopancreatography (ERCP) images for evaluation of MPD and CBD. CBD was more clearly demonstrated by MRCP than MPD. Both MPD and CBD were more clearly seen in the mild group than in the severe group. A few false-negative cases were seen in MRCP. T2 weighed MR images were almost the same as contrast-enhanced CT images in diagnosis of acute pancreatitis. MRCP is useful for evaluation of CBD in severe cases and for evaluation of both CBD and MPD in mild cases of acute pancreatitis. The severity of disease can be evaluated by combination of T2 weighted MR images and MRCP alternative to contrast-enhanced CT. (author)

  17. Hepatic involvement of Langerhans cell histiocytosis in children - imaging findings of computed tomography, magnetic resonance imaging and magnetic resonance cholangiopancreatography

    International Nuclear Information System (INIS)

    Shi, Yingyan; Qiao, Zhongwei; Gong, Ying; Yang, Haowei; Li, Guoping; Pa, Mier; Xia, Chunmei

    2014-01-01

    Langerhans cell histiocytosis is a rare disease that occurs mainly in children, and hepatic involvement is generally a poor prognostic factor. To describe CT and MRI findings of hepatic involvement of Langerhans cell histiocytosis in children, especially the abnormal bile duct manifestation on magnetic resonance cholangiopancreatography (MRCP). Thirteen children (seven boys, six girls; mean age 28.9 months) were diagnosed with disseminated Langerhans cell histiocytosis. They underwent CT (n = 5) or MRI (n = 4), or CT and MRI examinations (n = 4) to evaluate the liver involvement. Periportal abnormalities presented as band-like or nodular lesions on CT and MRI in all 13 children. The hepatic parenchymal lesions were found in the peripheral regions of the liver in seven children, including multiple nodules on MRI (n = 6), and cystic-like lesions on CT and MRI (n = 3). In 11 of the 13 children the dilatations of the bile ducts were observed on CT and MRI. Eight of the 13 children underwent MR cholangiopancreatography, which demonstrated stenoses or segmental stenoses with slight dilatation of the central bile ducts, including the common hepatic duct and its first-order branches. The peripheral bile ducts in these children showed segmental dilatations and stenoses. Stenosis of the central bile ducts revealed by MR cholangiopancreatography was the most significant finding of liver involvement in Langerhans cell histiocytosis in children. (orig.)

  18. Hepatic involvement of Langerhans cell histiocytosis in children - imaging findings of computed tomography, magnetic resonance imaging and magnetic resonance cholangiopancreatography

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Yingyan; Qiao, Zhongwei; Gong, Ying; Yang, Haowei; Li, Guoping; Pa, Mier [Children' s Hospital of Fudan University, Department of Radiology, Shanghai (China); Xia, Chunmei [Shanghai Medical College of Fudan University, Physiology and Pathophysiology Department, Shanghai (China)

    2014-06-15

    Langerhans cell histiocytosis is a rare disease that occurs mainly in children, and hepatic involvement is generally a poor prognostic factor. To describe CT and MRI findings of hepatic involvement of Langerhans cell histiocytosis in children, especially the abnormal bile duct manifestation on magnetic resonance cholangiopancreatography (MRCP). Thirteen children (seven boys, six girls; mean age 28.9 months) were diagnosed with disseminated Langerhans cell histiocytosis. They underwent CT (n = 5) or MRI (n = 4), or CT and MRI examinations (n = 4) to evaluate the liver involvement. Periportal abnormalities presented as band-like or nodular lesions on CT and MRI in all 13 children. The hepatic parenchymal lesions were found in the peripheral regions of the liver in seven children, including multiple nodules on MRI (n = 6), and cystic-like lesions on CT and MRI (n = 3). In 11 of the 13 children the dilatations of the bile ducts were observed on CT and MRI. Eight of the 13 children underwent MR cholangiopancreatography, which demonstrated stenoses or segmental stenoses with slight dilatation of the central bile ducts, including the common hepatic duct and its first-order branches. The peripheral bile ducts in these children showed segmental dilatations and stenoses. Stenosis of the central bile ducts revealed by MR cholangiopancreatography was the most significant finding of liver involvement in Langerhans cell histiocytosis in children. (orig.)

  19. Normal pancreatic exocrine function does not exclude MRI/MRCP chronic pancreatitis findings.

    Science.gov (United States)

    Alkaade, Samer; Cem Balci, Numan; Momtahen, Amir Javad; Burton, Frank

    2008-09-01

    Abnormal pancreatic function tests have been reported to precede the imaging findings of chronic pancreatitis. Magnetic resonance imaging (MRI) with magnetic resonance cholangiopancreatography (MRCP) is increasingly accepted as the primary imaging modality for the detection of structural changes of early mild chronic pancreatitis. The aim of this study was to evaluate MRI/MRCP findings in patients with symptoms consistent with chronic pancreatitis who have normal Secretin Endoscopic Pancreatic Function test. A retrospective study of 32 patients referred for evaluation of chronic abdominal pain consistent with chronic pancreatitis and reported normal standard abdominal imaging (ultrasound, computed tomography, or MRI). All patients underwent Secretin Endoscopic Pancreatic Function testing and pancreatic MRI/MRCP at our institution. We reviewed the MRI/MRCP images in patients who had normal Secretin Endoscopic Pancreatic Function testing. MRI/MRCP images were assessed for pancreatic duct morphology, gland size, parenchymal signal and morphology, and arterial contrast enhancement. Of the 32 patients, 23 had normal Secretin Endoscopic Pancreatic Function testing, and 8 of them had mild to marked spectrum of abnormal MRI/MRCP findings that were predominantly focal. Frequencies of the findings were as follows: pancreatic duct stricture (n=3), pancreatic duct dilatation (n=3), side branch ectasia (n=4), atrophy (n=5), decreased arterial enhancement (n=5), decreased parenchymal signal (n=1), and cavity formation (n=1). The remaining15 patients had normal pancreatic structure on MRI/MRCP. Normal pancreatic function testing cannot exclude abnormal MRI/MRCP especially focal findings of chronic pancreatitis. Further studies needed to verify significance of these findings and establish MRI/MRCP imaging criteria for the diagnosis of chronic pancreatitis.

  20. Cost-effectiveness analysis of endoscopic ultrasound versus magnetic resonance cholangiopancreatography in patients with suspected common bile duct stones.

    Directory of Open Access Journals (Sweden)

    Stephen Morris

    Full Text Available Patients with suspected common bile duct (CBD stones are often diagnosed using endoscopic retrograde cholangiopancreatography (ERCP, an invasive procedure with risk of significant complications. Using endoscopic ultrasound (EUS or Magnetic Resonance CholangioPancreatography (MRCP first to detect CBD stones can reduce the risk of unnecessary procedures, cut complications and may save costs.This study sought to compare the cost-effectiveness of initial EUS or MRCP in patients with suspected CBD stones.This study is a model based cost-utility analysis estimating mean costs and quality-adjusted life years (QALYs per patient from the perspective of the UK National Health Service (NHS over a 1 year time horizon. A decision tree model was constructed and populated with probabilities, outcomes and cost data from published sources, including one-way and probabilistic sensitivity analyses.Using MRCP to select patients for ERCP was less costly than using EUS to select patients or proceeding directly to ERCP ($1299 versus $1753 and $1781, respectively, with similar QALYs accruing to each option (0.998, 0.998 and 0.997 for EUS, MRCP and direct ERCP, respectively. Initial MRCP was the most cost-effective option with the highest monetary net benefit, and this result was not sensitive to model parameters. MRCP had a 61% probability of being cost-effective at $29,000, the maximum willingness to pay for a QALY commonly used in the UK.From the perspective of the UK NHS, MRCP was the most cost-effective test in the diagnosis of CBD stones.

  1. The exploratory development of A self-made oral Gd-DTPA solution for low field MRCP in children

    International Nuclear Information System (INIS)

    Sheng Mao; Zhou Min; Gu Zhicheng; Wu Jizhi; Guo Wanliang; Ni Yongbiao; Fang Lin

    2010-01-01

    Objective: To evaluate the value of ingestion self-made Gd-DTPA solutin for low field magnetic resonance cholangiopancreatography (MRCP) (0.35T) in children. Methods: Phantom experiments were performed to select the optimal concentration of Gd-DTPA to be used as an oral negative contrast agent in low field MRCP. Twenty children suspected of celiac disease were performed with MRCP before and after ingestion Gd-DTPA solution. Signal intensity measurements of gastroduodenal lumens, pancreatobiliary ducts, and image quality scores were obtained systematically before and after contrast ingestion. Results: The selected Gd-DTPA concentration was 1.992 mmol/L. Ingestion of 80 ml solution eliminated or suppressed efficiently the gastroduodenal signal intensity, improving the MRCP image quality scores (P<0.01) significantly in children. Conclusion: 1.992 mmol/L self-made Gd-DTPA solutin can suppress or eliminate water signals from gastrointestinal tract and improve the quality of low field MRCP image in children. (authors)

  2. Magnetic resonance cholangiopancreatography in the diagnosis of pancreas divisum: a systematic review and meta-analysis.

    Science.gov (United States)

    Rustagi, Tarun; Njei, Basile

    2014-08-01

    This study aimed to perform a structured meta-analysis of all eligible studies to assess the overall diagnostic use of magnetic resonance cholangiopancreatography (MRCP) alone or with secretin enhancement (secretin-enhanced MRCP [S-MRCP]) in the detection of pancreas divisum. Two authors independently performed a comprehensive search of PubMed, MEDLINE, and the Cochrane Library from inception to September 2013. Studies were included if they allowed construction of 2 × 2 contingency tables of MRCP and/or S-MRCP compared with criterion standard. DerSimonian-Laird random effect models were used to estimate the pooled sensitivity, specificity, specificity, and quantitative receiver operating characteristics. Of 51 citations, 10 studies with 1474 patients were included. Secretin-enhanced MRCP had a higher overall diagnostic performance than MRCP (S-MRCP: pooled sensitivity, 86% [95% confidence interval (CI), 77%-93%]; specificity, 97% [95% CI, 94%-99%]; and area under the curve, 0.93 ± 0.056 compared with MRCP: sensitivity, 52% [95% CI, 45%-59%]; specificity, 97% [95% CI, 94%-99%]; and area under the curve, 0.76 ± 0.104). Pooled diagnostic odds ratios were 72.19 (95% CI, 5.66-938.8) and 23.39 (95% CI, 7.93-69.02) for S-MRCP and MRCP, respectively. Visual inspection of the funnel plot showed low potential for publication bias. Secretin-enhanced MRCP has a much higher diagnostic accuracy than MRCP and should be preferred for diagnosis of pancreas divisum.

  3. Inpatient magnetic resonance cholangiopancreatography: does it increase the efficiency in emergency hepatopancreaticobiliary surgery services?

    Science.gov (United States)

    Milburn, J A; Bailey, J A; Dunn, Wk; Cameron, I C; Gomez, D S

    2017-04-01

    INTRODUCTION Magnetic resonance cholangiopancreatography (MRCP) is commonly used to evaluate the biliary tree, although indications for patients who require inpatient imaging are not fully defined. The aim of this study was to evaluate inpatient MRCP performed on surgical patients and to devise a treatment pathway for these patients. MATERIAL AND METHODS All adult inpatient MRCP examinations between January 2012 and December 2013 were reviewed. Demographic, clinical and radiological data were collated. RESULTS During the study period, 271 inpatient MRCP were requested, of which 234 examinations were included. The majority of patients were female (n=140) and the median age was 63 years (range 16-93 years). Surgical admissions accounted for 171 (73%) of cases. Indications for inpatient MRCP include gallstone-related complications (n=173; 74%), malignant process (n=17; 7%) and other indications (n=44; 19%). Overall, inpatient MRCP led to further inpatient interventions in 22% (gallstone group, n=32, 18%; patients with malignancy, n=8, 47%; other indications, n=12, 27%). The median duration of inpatient MRCP from request to examination was 2 days (range 0-15 days) and median reporting after examination was 1 day (range 0-14 days). DISCUSSION AND CONCLUSION Improved access and timely reporting of iMRCP may reduce length of hospital stay. Inpatient MRCP also led to further inpatient interventions, in particular, in patients with malignancy.

  4. Evaluation of dynamic MRCP after secretin stimulation for biliopancreatic diseases

    International Nuclear Information System (INIS)

    Ohhigashi, Seiji; Nishio, Takeki; Watanabe, Fumihiko; Haradome, Hiroki; Doi, Osamu

    2000-01-01

    Both pancreaticobiliary maljunction and pancreatogastrostomy after pancreatoduodenectomy were analyzed to assess the utility of dynamic MRCP after secretin stimulation. Dynamic MRCP obtained every 60 seconds for 15 minutes after secretin administration revealed the bile and pancreatic fluid kinetics. Calculating the intensity value from the MR images allowed objective estimation of the bile and pancreatic fluid kinetics. Thus, this study demonstrated that dynamic MRCP after secretin stimulation was significantly useful in evaluating not only the morphologic features in pancreaticobiliary maljunction but also pancreatic exocrine function after resection of the pancreas. (author)

  5. An incidental case of biliary fascioliasis with subtle clinical findings: US and MRCP findings

    International Nuclear Information System (INIS)

    Önder, Hakan; Ekici, Faysal; Adin, Emin; Kuday, Suzan; Gümüş, Hatice; Bilici, Aslan

    2013-01-01

    Fascioliasis is a disease caused by the trematode Fasciola hepatica. Cholangitis is a common clinical manifestation. Although fascioliasis may show various radiological and clinical features, cases without biliary dilatation are rare. We present unique ultrasound (US) and magnetic resonance cholangiopancreatography (MRCP) findings of a biliary fascioliasis case which doesn’t have biliary obstruction or cholestasis. Radiologically, curvilinear parasites compatible with juvenile and mature Fasciola hepatica within the gallbladder and common bile duct were found. The parasites appear as bright echogenic structures with no acoustic shadow on US and hypo-intense curvilinear lesions on T2 weighted MRCP images. Imaging studies may significantly contribute to the diagnosis of patients with subtle clinical and laboratory findings, particularly in endemic regions

  6. Assessment of MRI and MRCP in diagnosis of biliary cystadenoma and cystadenocarcinoma

    International Nuclear Information System (INIS)

    Lewin, Maite; Arrive, Lionel; Tubiana, Jean-Michel; Mourra, Najat; Flejou, Jean-Francois; Honigman, Isabelle; Parc, Rolland

    2006-01-01

    Magnetic resonance imaging (MRI) and magnetic resonance cholangio-pancreatography (MRCP) features were analyzed in the diagnosis of seven surgically resected hepatobiliary cystic tumors with reference to histopathological data. Homogeneity, size, location, signal intensity, presence or absence of septa and/or nodules and MRCP features of the lesions were studied. Histological evidence demonstrated six biliary cystadenoma (BCA) including four pseudo-ovarian stroma (POS) and one biliary cystadenocarcinoma (BCAC). Cystic lesions (3-15 cm in diameter) were homogeneous in the six BCA, heterogeneous in the one BCAC, and were located in the left and right liver, respectively. On T2-weighted images all lesions were hyperintense. On T1-weighted images hypointensity was found in three BCA (all serous fluid, including one POS), isointensity was found in the three others (two mucinous and one hemorrhagic fluid, including three POS) and in the one BCAC (containing mucinous fluid). Septas were present in all cases and nodules only in the one BCAC. On MRCP a hyperintense cystic lesion was found in all cases and a bile ducts dilatation in two BCA and the one BCAC. Gadolinium-enhanced MRI in combination with MRCP is a valuable tool for the diagnosis of BCA or BCAC. However, no specific information is gained for POS detection. (orig.)

  7. The effective use of acai juice, blueberry juice and pineapple juice as negative contrast agents for magnetic resonance cholangiopancreatography in children

    International Nuclear Information System (INIS)

    Bittman, Mark E.; Callahan, Michael J.

    2014-01-01

    Magnetic resonance cholangiopancreatography (MRCP) is commonly performed in the evaluation of known or suspected pancreaticobiliary disease in children. The administration of a negative oral contrast agent can improve the quality of the examination without significant additional cost. We describe our experience with certain brands of acai juice, blueberry juice and pineapple juice as negative oral contrast agents in children. We believe these fruit juices are safe, palatable and may improve MRCP image quality. (orig.)

  8. The effective use of acai juice, blueberry juice and pineapple juice as negative contrast agents for magnetic resonance cholangiopancreatography in children

    Energy Technology Data Exchange (ETDEWEB)

    Bittman, Mark E. [Cohen Children' s Medical Center of New York, North Shore Long Island Jewish Health System, Department of Radiology, New Hyde Park, NY (United States); Callahan, Michael J. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States)

    2014-07-15

    Magnetic resonance cholangiopancreatography (MRCP) is commonly performed in the evaluation of known or suspected pancreaticobiliary disease in children. The administration of a negative oral contrast agent can improve the quality of the examination without significant additional cost. We describe our experience with certain brands of acai juice, blueberry juice and pineapple juice as negative oral contrast agents in children. We believe these fruit juices are safe, palatable and may improve MRCP image quality. (orig.)

  9. Noninvasive investigation of exocrine pancreatic function: Feasibility of cine dynamic MRCP with a spatially selective inversion-recovery pulse.

    Science.gov (United States)

    Yasokawa, Kazuya; Ito, Katsuyoshi; Tamada, Tsutomu; Yamamoto, Akira; Hayashida, Minoru; Tanimoto, Daigo; Higaki, Atsushi; Noda, Yasufumi; Kido, Ayumu

    2015-11-01

    To investigate the feasibility of noncontrast-enhanced cine dynamic magnetic resonance cholangiopancreatography (MRCP) with a spatially selective inversion-recovery (IR) pulse for evaluating exocrine pancreatic function in comparison with the N-benzoyl-L-tyrosyl-p-aminobenzoic acid (BT-PABA) test as a pancreatic exocrine function test. Twenty subjects with or without chronic pancreatitis were included. MRCP with a spatially selective IR pulse was repeated every 15 seconds for 5 minutes to acquire a total of 20 images (cine-dynamic MRCP). The median and mean frequency of the observation (the number of times) and the moving distance (mean secretion grading scores) of pancreatic juice inflow on cine-dynamic MRCP were compared with a BT-PABA test. The urinary PABA excretion rate (%) had significant positive correlations with both the mean secretion grade (r = 0.66, P = 0.002) and frequency of secretory inflow (r = 0.62, P = 0.004) in cine dynamic MRCP. Both the mean frequency of observations of pancreatic secretory inflow (1.4 ± 1.6 times vs. 14.3 ± 4.2 times, P Cine dynamic MRCP with a spatially selective IR pulse may have potential for estimating the pancreatic exocrine function noninvasively as a substitute for the BT-PABA test. © 2015 Wiley Periodicals, Inc.

  10. Oral gadopentetate dimeglumine administration as a negative gastrointestinal contrast agent to improve image quality of MR cholangiopancreatography

    International Nuclear Information System (INIS)

    Chen Yi; Xu Yikai; Zhao Yuhui; Wang Guisheng

    2008-01-01

    Objective: To choose optimal concentration and volume of Gd-DTPA solution as a oral gastrointestinal negative contrast agent for MRCP. To evaluate the role of Gd-DTPA solution in improving image quality of MRCP. Methods: In vitro experiment: Gd-DTPA solution was made with different concentrations. T 1 WI, T 2 WI, two-dimensional single slice fast spin echo sequence and three-dimensional half-fourier acquisition single-shot fast spin echo sequence were performed to measure the signal intensity of these contrast agents respectively, so Gd-DTPA solution with the optimal concentration can be decided as oral negative gastrointestinal contrast agent on MRCP. Clinical study: The Gd-DTPA solution with optimal concentration and volume was regarded as an oral negative gastrointestinal contrast agent of MRCP. Twenty- four' patients were performed with MRCP before and after (5-10 minutes and 10-15 minutes) administration of oral negative gastrointestinal contrast agent and image quality was analyzed. Statistical analysis was performed using analysis of variance with SPSS 10.0. Results: When the concentration of Gd-DTPA solution was ≤0.01 mol/L, the contrast agent was hyperintense on T 1 WI. On T 2 WI, when the concentration was ≥0.015 mol/L, it was as hypointense as basic ground; On 2D FSE MRCP images, controls were hyperintense and the contrast agent with concentration ranging from 0.0025 mol/L to 0.03 mol/L was hypointense. On 3D HEAST MRCP image, controls were hyperintense and when the concentration of Gd-DTPA was ≥0.01 mol, the contrast agent was hypointense. The Gd-DTPA solution with the concentration of 0.01 mol/L and the volume of 100 ml was chosen as MRCP oral negative gastrointestinal contrast agent. On MRCP images after oral administration of the contrast agent, in 10-15 minutes, the average grade scores within 24 patients of the intrahepatic bile duct, the common hepatic bile duct, the gall bladder, the common bile duct and pancreatic duct (the average grade

  11. Role of diffusion-weighted magnetic resonance imaging in the diagnosis of extrahepatic cholangiocarcinoma

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    AIM: To determine the clinical value of diffusion-weight- ed imaging (DWI) for the diagnosis of extrahepatic cholangiocarcinoma (EHCC) by comparing the diagnostic sensitivity of DWI and magnetic resonance cholan-giopancreatography (MRCP). METHODS: Magnetic resonance imaging examination was performed in 56 patients with suspected EHCC. T1- weighted imaging, T2-weighted imaging, MRCP and DWI sequence, DWI using single-shot spin-echo echoplanar imaging sequence with different b values (100, 300, 500, 800 and 1...

  12. MR imaging of primary sclerosing cholangitis - Additional value of diffusion-weighted imaging and ADC measurement

    Energy Technology Data Exchange (ETDEWEB)

    Djokicc Kovac, Jelena [Center for Radiology and Magnetic Resonance Imaging, Clinical Center Serbia, Belgrade (Serbia)], e-mail: jelenadjokic2003@yahoo.co.uk; Maksimovic, Ruzica [Center for Radiology and Magnetic Resonance Imaging, Clinical Center Serbia, Belgrade (Serbia); Faculty of Medicine, Univ. of Belgrade, Belgrade (Serbia); Jesic, Rada [Clinic for Gastroenterohepatology, Clinical Center Serbia, Belgrade (Serbia); Faculty of Medicine, Univ. of Belgrade, Belgrade (Serbia); Stanisavljevic, Dejana [Inst. for Statistics, Faculty of Medicine, Univ. of Belgrade, Belgrade (Serbia); Kovac, Bojan [Military Medical Academy, Belgrade (Serbia)

    2013-04-15

    Background: Primary sclerosing cholangitis (PSC) is a cholestatic liver disease with chronic inflammation and progressive destruction of biliary tree. Magnetic resonance (MR) examination with diffusion-weighted imaging (DWI) allows analysis of morphological liver parenchymal changes and non-invasive assessment of liver fibrosis. Moreover, MR cholangiopancreatography (MRCP), as a part of standard MR protocol, provides insight into bile duct irregularities. Purpose: To evaluate MR and MRCP findings in patients with primary sclerosing cholangitis and to determine the value of DWI in the assessment of liver fibrosis. Material and Methods: The following MR findings were reviewed in 38 patients: abnormalities in liver parenchyma signal intensity, changes in liver morphology, lymphadenopathy, signs of portal hypertension, and irregularities of intra- and extrahepatic bile ducts. Apparent diffusion coefficient (ADC) was calculated for six locations in the liver for b = 800 s/mm{sup 2}. Results: T2-weighted hyperintensity was seen as peripheral wedge-shaped areas in 42.1% and as periportal edema in 28.9% of patients. Increased enhancement of liver parenchyma on arterial-phase imaging was observed in six (15.8%) patients. Caudate lobe hypertrophy was present in 10 (26.3%), while spherical liver shape was noted in 7.9% of patients. Liver cirrhosis was seen in 34.2% of patients; the most common pattern was micronodular cirrhosis (61.5%). Other findings included lymphadenopathy (28.9%), signs of portal hypertension (36.7%), and bile duct irregularities (78.9%). The mean ADCs (x10{sup -3} mm{sup 2}/s) were significantly different at stage I vs. stages III and IV, and stage II vs. stage IV. No significant difference was found between stages II and III. For prediction of stage {>=}II and stage {>=}III, areas under receiver-operating characteristic curves were 0.891 and 0.887, respectively. Conclusion: MR with MRCP is a necessary diagnostic procedure for diagnosis of PSC and

  13. Does secretin add value in pediatric magnetic resonance cholangiopancreatography?

    International Nuclear Information System (INIS)

    Trout, Andrew T.; Podberesky, Daniel J.; Serai, Suraj D.; Towbin, Alexander J.; Ren, Yan; Altaye, Mekebib

    2013-01-01

    Secretin - a hormone that stimulates pancreatic exocrine secretion - is described to improve visualization of the pancreatic duct by magnetic resonance cholangiopancreatography (MRCP). In our pediatric practice, however, we have not observed substantial benefit with the use of secretin. To determine whether secretin dilates and improves visualization of the pancreatic duct in pediatric MRCP. Retrospective evaluation of secretin-enhanced MRCPs performed over a 15-month period. One reviewer measured the pancreatic duct pre- and post-secretin and two reviewers, blinded to the administration of secretin, assessed image quality and subjective duct visibility. Similar assessments of the biliary tree served as internal controls. We reviewed 20 MRCPs in 17 children. Following secretin administration, there was a small (0.3 mm) but statistically significant increase in pancreatic duct diameter (P = 0.002) and small (<0.2 mm) but significant increase in intrahepatic bile duct diameter (P = 0.0104). On subjective review, there was no significant difference in image quality or duct visibility based on the administration of secretin. Secretin induces dilatation of the pancreatic duct but the value of that effect in pediatric MRCP is suspect given the small change in duct diameter and the lack of improvement in image quality and duct visibility. (orig.)

  14. Quality rating of MR-cholangiopancreatography with oral application of iron oxide particles; Wertigkeit der MR-Cholangiopankreatikographie nach Gabe eines oralen eisenhaltigen Kontrastmittels

    Energy Technology Data Exchange (ETDEWEB)

    Lorenzen, M.; Wedegaertner, U.; Fiehler, J.; Adam, G. [Universitaetsklinikum Hamburg, Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie (Germany)

    2003-07-01

    Purpose: To compare image quality in magnetic resonance cholangiopancreatography (MRCP) performed with and without oral application of Loesferron {sup trademark} (ferrous gluconate, Lilly Pharma, Hamburg). Materials and Methods: A prospective study compares MRCPs performed on 52 patients with a 1.5 T clinical whole body scanner using a standard body coil. After randomization, patients ingested either 0.5 l of Loeseferron {sup trademark} (n=27, group 1) or no oral contrast agent (n=25, group 2) prior to the examination. 7 RARE (40 to 20 ) sequences were obtained, followed by selected 3 mm HASTE (T{sub 2}-weighted with fat suppression) sequences. After blinding, image quality was rated by two radiologists using a scale of 1 (not discernible) to 5 (very well discernible). The following sections of the biliary ductal system were evaluated: left and right hepatic duct, extrahepatic bile duct and intrapancreatic bile duct. The pancreatic duct was evaluated by its location: head, body and tail of the pancreas. A Wilcoxon-Mann-Whitney test was used to determine significant differences (p<0.05) between sampled ductal segments. Correction for multiple testing was applied. Results: The oral application of Loeseferron {sup trademark} was well tolerated by all patients, and all sequences could be acquired and evaluated in all 52 patients. For the different sections of the biliary system, the mean ratings with and without Loesferron {sup trademark} were, respectively, 3.28 and 3.36 for the left hepatic duct, 3.26 and 3.33 for the right hepatic duct, 3.46 and 4.0 for the extrahepatic bile duct, and 2.8 and 3.48 for the intrapancreatic bile duct. The corresponding ratings for the pancreatic duct were 2.8 and 3.24 for the pancreatic head, 2.84 and 3.38 for the pancreatic body, and 2.68 and 3.22 for the pancreatic tail. The differences with and without contrast agent were not statistically significant. Interobserver variability was between 0.37 for the pancreatic duct in the tail of

  15. Does secretin stimulation add to magnetic resonance cholangiopancreatography in characterising pancreatic cystic lesions as side-branch intraductal papillary mucinous neoplasm?

    International Nuclear Information System (INIS)

    Purysko, Andrei S.; Gandhi, Namita S.; Veniero, Joseph C.; Walsh, R.M.; Obuchowski, Nancy A.

    2014-01-01

    To assess the value of secretin during magnetic resonance cholangiopancreatography (MRCP) in demonstrating communication between cystic lesions and the pancreatic duct to help determine the diagnosis of side-branch intraductal papillary mucinous neoplasm (SB-IPMN). This is an IRB-approved, HIPAA-compliant retrospective study of 29 SB-IPMN patients and 13 non-IPMN subjects (control) who underwent secretin-enhanced MRCP (s-MRCP). Two readers blinded to the final diagnosis reviewed three randomised image sets: (1) pre-secretin HASTE, (2) dynamic s-MRCP and (3) post-secretin HASTE. Logistic regression, generalised linear models and ROC analyses were used to compare pre- and post-secretin results. There was no significant difference in median scores for the pre-secretin [reader 1: 1; reader 2: 2 (range -2 to 2)] and post-secretin HASTE [reader 1: 1; reader 2: 1 (range -2 to 2)] in the SB-IPMN group (P = 0.14), while the scores were lower for s-MRCP [reader 1: 0.5 (range -2 to 2); reader 2: 0 (range -1 to 2); P = 0.016]. There was no significant difference in mean maximum diameter of SB-IPMN on pre- and post-secretin HASTE, and s-MRCP (P > 0.05). Secretin stimulation did not add to MRCP in characterising pancreatic cystic lesions as SB-IPMN. (orig.)

  16. MRCP and 3D LAVA imaging of extrahepatic cholangiocarcinoma at 3 T MRI

    Energy Technology Data Exchange (ETDEWEB)

    Li, N.; Liu, C.; Bi, W.; Lin, X.; Jiao, H. [Shandong Medical Imaging Research Institute, Shandong University, Jinan (China); Zhao, P., E-mail: Gavinsdu@163.com [Department of Radiology, Shandong Provincial Hospital, Shandong University, Jinan (China)

    2012-06-15

    Extrahepatic cholangiocarcinoma (CCA) is a primary bile duct malignant tumour with poor prognosis. Familiarity with their varied imaging characteristics can be helpful in developing a correct diagnosis and in optimal treatment planning, and thus contribute to a better prognosis. The purpose of this article is to illustrate the typical appearances of extrahepatic CCA on magnetic resonance cholangiopancreatography (MRCP) and three-dimensional (3D) LAVA (liver acquisition with volume acceleration) sequences at 3 T magnetic resonance imaging (MRI), and to discuss the superiority of the two techniques in the diagnosis of CCA.

  17. Clinical role of secretin loading magnetic resonance cholangiopancreatography in the patients undergoing pancreatic resection

    Energy Technology Data Exchange (ETDEWEB)

    Shimada, Ken; Takahashi, Tsuyoshi; Yoshida, Muneki; Kakita, Akira [Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Medicine

    2002-01-01

    We determined factors contributing to increased signal intensity in the reconstructed jejunal loop in patients undergoing pancreatic resection, frequently observed on magnetic resonance cholangiopancreatography following intravenous injection of secretin (S/MRCP). We also evaluated the possible roles of S/MRCP in assessing the patency of pancreatojejunal anastomosis and the secretory function of the remnant pancreas. Subject were 44 patients undergoing several types of pancreatic resection. Baseline output and response to secretin of the remnant pancreas were measured after surgery. S/MRCP and pancreatic function diagnostant (PFD) tests were conducted preoperatively, and in early and late periods after surgery. Baseline pancreatic output was 1.2{+-}0.7 ml/10-min, and increased after secretin load to a maximum 9.0{+-}6.6 ml/10-min in 10 min. Signal intensity of the jejunal loop increased in 2 patients versus 40 patients (95%) during the early versus late postoperative periods. During the late period, PFD was significantly higher in patients with increased signal intensity than in those without. PFD correlated well with cumulative pancreatic output following secretin loading (r=0.820). A major factor responsible for increased signal intensity in S/MRCP of the jejunal loop was increased pancreatic output. The increase in signal intensity was a definitive sign of patent pancreatojejunal anastomosis. S/MRCP thus seems to have a potential for evaluating the secretory function of the remnant pancreas. (author)

  18. Clinical role of secretin loading magnetic resonance cholangiopancreatography in the patients undergoing pancreatic resection

    International Nuclear Information System (INIS)

    Shimada, Ken; Takahashi, Tsuyoshi; Yoshida, Muneki; Kakita, Akira

    2002-01-01

    We determined factors contributing to increased signal intensity in the reconstructed jejunal loop in patients undergoing pancreatic resection, frequently observed on magnetic resonance cholangiopancreatography following intravenous injection of secretin (S/MRCP). We also evaluated the possible roles of S/MRCP in assessing the patency of pancreatojejunal anastomosis and the secretory function of the remnant pancreas. Subject were 44 patients undergoing several types of pancreatic resection. Baseline output and response to secretin of the remnant pancreas were measured after surgery. S/MRCP and pancreatic function diagnostant (PFD) tests were conducted preoperatively, and in early and late periods after surgery. Baseline pancreatic output was 1.2±0.7 ml/10-min, and increased after secretin load to a maximum 9.0±6.6 ml/10-min in 10 min. Signal intensity of the jejunal loop increased in 2 patients versus 40 patients (95%) during the early versus late postoperative periods. During the late period, PFD was significantly higher in patients with increased signal intensity than in those without. PFD correlated well with cumulative pancreatic output following secretin loading (r=0.820). A major factor responsible for increased signal intensity in S/MRCP of the jejunal loop was increased pancreatic output. The increase in signal intensity was a definitive sign of patent pancreatojejunal anastomosis. S/MRCP thus seems to have a potential for evaluating the secretory function of the remnant pancreas. (author)

  19. Quantification of pancreatic exocrine function with secretin-enhanced magnetic resonance cholangiopancreatography: normal values and short-term effects of pancreatic duct drainage procedures in chronic pancreatitis. Initial results

    International Nuclear Information System (INIS)

    Bali, M.A.; Sztantics, A.; Metens, T.; Matos, C.; Arvanitakis, M.; Delhaye, M.; Deviere, J.

    2005-01-01

    The aim of this study was to quantify pancreatic exocrine function in normal subjects and in patients with chronic pancreatitis (CP) before and after pancreatic duct drainage procedures (PDDP) with dynamic secretin-enhanced magnetic resonance (MR) cholangiopancreatography (S-MRCP). Pancreatic exocrine secretions [quantified by pancreatic flow output (PFO) and total excreted volume (TEV)] were quantified twice in ten healthy volunteers and before and after treatment in 20 CP patients (18 classified as severe, one as moderate, and one as mild according to the Cambridge classification). PFO and TEV were derived from a linear regression between MR-calculated volumes and time. In all subjects, pancreatic exocrine fluid volume initially increased linearly with time during secretin stimulation. In controls, the mean PFO and TEV were 6.8 ml/min and 97 ml; intra-individual deviations were 0.8 ml/min and 16 ml. In 10/20 patients with impaired exocrine secretions before treatment, a significant increase of PFO and TEV was observed after treatment (P<0.05); 3/20 patients presented post-procedural acute pancreatitis and a reduced PFO. The S-MRCP quantification method used in the present study is reproducible and provides normal values for PFO and TEV in the range of those obtained from previous published intubation studies. The initial results in CP patients have demonstrated non-invasively a significant short-term improvement of PFO and TEV after PDDP. (orig.)

  20. Noninvasive study of anatomic variations of the bile and pancreatic duct using magnetic resonance cholangiopancreatography; Estudio no invasivo de variantes anatomicas de la via biliar y pancreatica mediante colangiopancreatografia por resonancia magnetica (CPRM)

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, E.; Falco, J.; Campo, R.; Martin, J.; Brullet, E. [SDI-UDIAT Corporacio Sanitaria Parc Tauli. Sabadell (Spain); Espinos, J. [Hospital Mutua de Tarrasa (Spain)

    1999-07-01

    To identify anatomic variations of the bile duct and pancreatic duct and papillary anomalies by means of magnetic resonance cholangiopancreatography (MRCP) and determine their correlation with endoscopic retrograde cholangiopancreatography (ERCP) findings. Eighty-five patients were selected by means of a prospective study comparing MRCP and ERCP. Coronal and axial HASTE images and coronal and oblique coronal RARE images were acquired in all the patients. Four of the studies (6%) were excluded because of poor technical quality. Anatomic variations were observed in 26 cases (30.5%), including trifurcation (n=7; 27%), right hepatic duct draining into left hepatic duct (n=2, 7.7%), right hepatic duct draining into common bile duct (n=4; 15.4%), extrahepatic confluence (n=2; 7.7%), medial cystic duct (n=2; 7.7%), parallel cystic duct (n=3; 11.5%), juxtapapillary duodenal diverticulum (n=3; 11.5%) and pancreas divisum (n=3; 11.5%). A good correlation was observed between the MRCP and ERCP findings. The introduction of MRCP into the noninvasive study of biliary disease may be useful in the detection of anatomic variations relevant to laparoscopic surgery and other endoscopic and interventional techniques. (Author) 11 refs.

  1. MRCP in the evaluation of pancreaticobiliary disease in children

    International Nuclear Information System (INIS)

    Arcement, C.M.; Meza, M.P.; Arumanla, S.; Towbin, R.B.

    2001-01-01

    Background. Radiologic assessment of pancreaticobiliary ductal disease (PBDD) in children currently consists of physiologic tests (radionuclide examinations) or invasive anatomic studies (ERCP and PTC). An accurate noninvasive and reproducible examination that can direct the subsequent need for more invasive studies would be helpful in this patient group. Objective. To determine the effectiveness of MRCP as a screening tool for PBBD in the pediatric population. Materials and methods. Over the last year, 33 patients ranging from 7 months to 20 years of age were prospectively evaluated with MRCP on a 1.5 T magnet. One patient was examined twice, several months apart. Thirteen patients had liver transplants. Coronal SPGR and heavily T-2W FSE cross-sectional images were obtained. Standard and oblique 2- to 6-cm-thick slab SSFSE (single-shot fast spin echo) acquisition and 3D MIP reconstruction of 2D FSE images were obtained in the planes of the CBD and pancreatic duct. Nine studies were performed with the patient under sedation with chloral hydrate or nembutal and fentanyl with quiet respiration, and the non-sedated patients were assessed with single breath hold or quiet respiration. Three patients received secretin. MRCP results were correlated with ERCP (9), PTC (7), liver biopsy (13), clinical information (6), surgery (3), and autopsy (2). Results. All 34 studies performed were considered diagnostic. Periportal fluid, proximal bowel fluid, and gallbladder distention did not significantly diminish the diagnostic information in any cases. Motion artifact did not cause serious degradation in image quality. MRCP depicted abnormalities including stones, stricture, intraductal tumor, and extrinsic compression, all of which were confirmed at ERCP, PTC (two unsuccessful in patients with non-dilated ducts by MRCP), surgery, liver biopsy, and autopsy. There were no false-negative examinations. Normal pancreatic studies performed to exclude pancreas divisum were followed

  2. MRCP in the evaluation of pancreaticobiliary disease in children

    Energy Technology Data Exchange (ETDEWEB)

    Arcement, C.M.; Meza, M.P.; Arumanla, S.; Towbin, R.B. [Children' s Hospital of Pittsburgh, Dept. of Radiology, Pittsburgh, PA (United States)

    2001-02-01

    Background. Radiologic assessment of pancreaticobiliary ductal disease (PBDD) in children currently consists of physiologic tests (radionuclide examinations) or invasive anatomic studies (ERCP and PTC). An accurate noninvasive and reproducible examination that can direct the subsequent need for more invasive studies would be helpful in this patient group. Objective. To determine the effectiveness of MRCP as a screening tool for PBBD in the pediatric population. Materials and methods. Over the last year, 33 patients ranging from 7 months to 20 years of age were prospectively evaluated with MRCP on a 1.5 T magnet. One patient was examined twice, several months apart. Thirteen patients had liver transplants. Coronal SPGR and heavily T-2W FSE cross-sectional images were obtained. Standard and oblique 2- to 6-cm-thick slab SSFSE (single-shot fast spin echo) acquisition and 3D MIP reconstruction of 2D FSE images were obtained in the planes of the CBD and pancreatic duct. Nine studies were performed with the patient under sedation with chloral hydrate or nembutal and fentanyl with quiet respiration, and the non-sedated patients were assessed with single breath hold or quiet respiration. Three patients received secretin. MRCP results were correlated with ERCP (9), PTC (7), liver biopsy (13), clinical information (6), surgery (3), and autopsy (2). Results. All 34 studies performed were considered diagnostic. Periportal fluid, proximal bowel fluid, and gallbladder distention did not significantly diminish the diagnostic information in any cases. Motion artifact did not cause serious degradation in image quality. MRCP depicted abnormalities including stones, stricture, intraductal tumor, and extrinsic compression, all of which were confirmed at ERCP, PTC (two unsuccessful in patients with non-dilated ducts by MRCP), surgery, liver biopsy, and autopsy. There were no false-negative examinations. Normal pancreatic studies performed to exclude pancreas divisum were followed

  3. Quality rating of MR-cholangiopancreatography with oral application of iron oxide particles

    International Nuclear Information System (INIS)

    Lorenzen, M.; Wedegaertner, U.; Fiehler, J.; Adam, G.

    2003-01-01

    Purpose: To compare image quality in magnetic resonance cholangiopancreatography (MRCP) performed with and without oral application of Loesferron trademark (ferrous gluconate, Lilly Pharma, Hamburg). Materials and Methods: A prospective study compares MRCPs performed on 52 patients with a 1.5 T clinical whole body scanner using a standard body coil. After randomization, patients ingested either 0.5 l of Loeseferron trademark (n=27, group 1) or no oral contrast agent (n=25, group 2) prior to the examination. 7 RARE (40 to 20 ) sequences were obtained, followed by selected 3 mm HASTE (T 2 -weighted with fat suppression) sequences. After blinding, image quality was rated by two radiologists using a scale of 1 (not discernible) to 5 (very well discernible). The following sections of the biliary ductal system were evaluated: left and right hepatic duct, extrahepatic bile duct and intrapancreatic bile duct. The pancreatic duct was evaluated by its location: head, body and tail of the pancreas. A Wilcoxon-Mann-Whitney test was used to determine significant differences (p trademark was well tolerated by all patients, and all sequences could be acquired and evaluated in all 52 patients. For the different sections of the biliary system, the mean ratings with and without Loesferron trademark were, respectively, 3.28 and 3.36 for the left hepatic duct, 3.26 and 3.33 for the right hepatic duct, 3.46 and 4.0 for the extrahepatic bile duct, and 2.8 and 3.48 for the intrapancreatic bile duct. The corresponding ratings for the pancreatic duct were 2.8 and 3.24 for the pancreatic head, 2.84 and 3.38 for the pancreatic body, and 2.68 and 3.22 for the pancreatic tail. The differences with and without contrast agent were not statistically significant. Interobserver variability was between 0.37 for the pancreatic duct in the tail of the pancreas and 0.66 for the right hepatic duct. Conclusion: Despite the trend toward a better rating of the image quality for all sections of the

  4. Sensitivity of endoscopic ultrasound, multidetector computed tomography, and magnetic resonance cholangiopancreatography in the diagnosis of pancreas divisum: a tertiary center experience.

    Science.gov (United States)

    Kushnir, Vladimir M; Wani, Sachin B; Fowler, Kathryn; Menias, Christine; Varma, Rakesh; Narra, Vamsi; Hovis, Christine; Murad, Faris M; Mullady, Daniel K; Jonnalagadda, Sreenivasa S; Early, Dayna S; Edmundowicz, Steven A; Azar, Riad R

    2013-04-01

    There are limited data comparing imaging modalities in the diagnosis of pancreas divisum. We aimed to: (1) evaluate the sensitivity of endoscopic ultrasound (EUS), magnetic resonance cholangiopancreatography (MRCP), and multidetector computed tomography (MDCT) for pancreas divisum; and (2) assess interobserver agreement (IOA) among expert radiologists for detecting pancreas divisum on MDCT and MRCP. For this retrospective cohort study, we identified 45 consecutive patients with pancreaticobiliary symptoms and pancreas divisum established by endoscopic retrograde pancreatography who underwent EUS and cross-sectional imaging. The control group was composed of patients without pancreas divisum who underwent endoscopic retrograde pancreatography and cross-sectional imaging. The sensitivity of EUS for pancreas divisum was 86.7%, significantly higher than the sensitivity reported in the medical records for MDCT (15.5%) or MRCP (60%) (P pancreas divisum; IOA was moderate (κ = 0.43). Endoscopic ultrasound is a sensitive test for diagnosing pancreas divisum and is superior to MDCT and MRCP. Review of MDCT studies by expert radiologists substantially raises its sensitivity for pancreas divisum.

  5. MR elastography in primary sclerosing cholangitis: correlating liver stiffness with bile duct strictures and parenchymal changes.

    Science.gov (United States)

    Bookwalter, Candice A; Venkatesh, Sudhakar K; Eaton, John E; Smyrk, Thomas D; Ehman, Richard L

    2018-04-07

    To determine correlation of liver stiffness measured by MR Elastography (MRE) with biliary abnormalities on MR Cholangiopancreatography (MRCP) and MRI parenchymal features in patients with primary sclerosing cholangitis (PSC). Fifty-five patients with PSC who underwent MRI of the liver with MRCP and MRE were retrospectively evaluated. Two board-certified abdominal radiologists in agreement reviewed the MRI, MRCP, and MRE images. The biliary tree was evaluated for stricture, dilatation, wall enhancement, and thickening at segmental duct, right main duct, left main duct, and common bile duct levels. Liver parenchyma features including signal intensity on T2W and DWI, and hyperenhancement in arterial, portal venous, and delayed phase were evaluated in nine Couinaud liver segments. Atrophy or hypertrophy of segments, cirrhotic morphology, varices, and splenomegaly were scored as present or absent. Regions of interest were placed in each of the nine segments on stiffness maps wherever available and liver stiffness (LS) was recorded. Mean segmental LS, right lobar (V-VIII), left lobar (I-III, and IVA, IVB), and global LS (average of all segments) were calculated. Spearman rank correlation analysis was performed for significant correlation. Features with significant correlation were then analyzed for significant differences in mean LS. Multiple regression analysis of MRI and MRCP features was performed for significant correlation with elevated LS. A total of 439/495 segments were evaluated and 56 segments not included in MRE slices were excluded for correlation analysis. Mean segmental LS correlated with the presence of strictures (r = 0.18, p duct strictures. Segments with increased LS show T2 hyperintensity, DWI hyperintensity, and post-contrast hyperenhancement. Global liver stiffness shows a moderate correlation with number of segmental strictures and significantly correlates with spleen stiffness, splenomegaly, and varices.

  6. Optimal sequence for magnetic resonance cholangiopancreatography

    Energy Technology Data Exchange (ETDEWEB)

    Kanzaki, Hiroshi; Akata, Soichi; Ozuki, Taizo; Abe, Kimihiko [Tokyo Medical Coll. (Japan)

    2001-09-01

    Magnetic resonance cholangiopancreatography (MRCP) has attracted attention as a useful examination for abnormalities of the pancreaticobiliary system, because it is a simple procedure. Since there are few detailed reports on optimal sequences for MRCP, we attempted to clarify the topic. The magnetic resonance imaging (MRI) equipment we used was a 1.0 Tesla super-conductive type. A fast spin echo (16 echo train) was used, and the echo space was set at 17 msec. TE was changed from 17 msec to 272 msec in 17 msec increments. TR was changed from 1,000 msec to 9,000 msec by 1,000 msec increments. Bile juice which had been collected from the PTCD tube of a patient with common bile duct cancer, was put in a test tube of 10 mm internal diameter. Saline was used as a substitute for pancreatic juice, because collection of pancreatic juice was difficult. Fat was used for contrast. Each signal intensity inside the test tube was measured and evaluated. We attempted to evaluate the signal of gastric juice by adding blueberry juice, making use of its manganese ion (Mn{sup ++}). With longer TR, the signal intensities of bile and pancreas juice increased. As TE became longer, the signal intensities of bile and pancreas juice decreased slightly, while that of fat decreased much more. In MRCP, it is necessary to set up a long TE to increase the relative signal intensity difference of fat in bile and pancreas juice. The signal intensity of gastric juice was made to disappear by the addition of blueberry juice diluted to a ratio of 1:3. (author)

  7. Optimal sequence for magnetic resonance cholangiopancreatography

    International Nuclear Information System (INIS)

    Kanzaki, Hiroshi; Akata, Soichi; Ozuki, Taizo; Abe, Kimihiko

    2001-01-01

    Magnetic resonance cholangiopancreatography (MRCP) has attracted attention as a useful examination for abnormalities of the pancreaticobiliary system, because it is a simple procedure. Since there are few detailed reports on optimal sequences for MRCP, we attempted to clarify the topic. The magnetic resonance imaging (MRI) equipment we used was a 1.0 Tesla super-conductive type. A fast spin echo (16 echo train) was used, and the echo space was set at 17 msec. TE was changed from 17 msec to 272 msec in 17 msec increments. TR was changed from 1,000 msec to 9,000 msec by 1,000 msec increments. Bile juice which had been collected from the PTCD tube of a patient with common bile duct cancer, was put in a test tube of 10 mm internal diameter. Saline was used as a substitute for pancreatic juice, because collection of pancreatic juice was difficult. Fat was used for contrast. Each signal intensity inside the test tube was measured and evaluated. We attempted to evaluate the signal of gastric juice by adding blueberry juice, making use of its manganese ion (Mn ++ ). With longer TR, the signal intensities of bile and pancreas juice increased. As TE became longer, the signal intensities of bile and pancreas juice decreased slightly, while that of fat decreased much more. In MRCP, it is necessary to set up a long TE to increase the relative signal intensity difference of fat in bile and pancreas juice. The signal intensity of gastric juice was made to disappear by the addition of blueberry juice diluted to a ratio of 1:3. (author)

  8. Comparison of 2D and 3D sequences for MRCP. Clinical value of the different techniques; Vergleich von 2D- und 3D-Sequenzen fuer die MRCP. Klinischer Stellenwert der einzelnen Techniken

    Energy Technology Data Exchange (ETDEWEB)

    Wallnoefer, A.M.; Herrmann, K.A.; Zech, C.J.; Gourtsoyianni, S.; Reiser, M.F.; Schoenberg, S.O. [Klinikum Grosshadern der Ludwig-Maximilian-Universitaet Muenchen (Germany). Institut fuer Klinische Radiologie; Beuers, U. [Klinikum Grosshadern der Ludwig-Maximilian-Universitaet Muenchen (Germany). Klinik fuer Innere Medizin II

    2005-11-01

    Magnetic resonance cholangio-pancreaticograpy (MRCP) is a non-invasive imaging modality of the pancreatico-biliary system which plays an increasingly important role in the clinical and diagnostic workup of patients with biliary or pancreatic diseases. The present review is designed to give an overview of the currently available and appropriate sequences, their technical background, as well as new developments and their relevance to the various clinical issues and challenges. The impact of the latest technical innovations, such as integrated parallel imaging techniques and navigator-based respiratory triggering, on the diagnostic capacities of MRCP is discussed. In this context, the individual value of RARE, T2w single shot turbo/fast spin echo (SSFSE) and the recently introduced 3D T2w turbo/fast spin echo sequences (T2w 3D-T/FSE) is reviewed. RARE imaging may be preferred in severely ill patients with limitations in cooperation, SSFSE is particularly effective in differentiating benign and malignant stenosis, and 3D-FSE offers additional advantages in the detection of small biliary concrements. (orig.) [German] Die Magnetresonanzcholangiopankreatikographie (MRCP) ist eine nichtinvasive Untersuchungsmethode des pankreatikobiliaeren Systems, die heute einen festen Platz in der klinischen Diagnostik eingenommen hat. Die vorliegende Arbeit gibt einen Ueberblick ueber die derzeit gaengigen Sequenzen, ihre technischen Grundlagen sowie ihre jeweilige Bedeutung in den verschiedenen klinischen Einsatzgebieten und Fragestellungen. Darueber hinaus werden die Bedeutung der parallelen Bildgebung, der navigatorbasierten Atemtriggerung und der neu eingefuehrten dreidimensionalen Sequenzen fuer die MRCP sowie ihre moeglichen Einsatzgebiete behandelt. Fuer die MRCP haben die 3 gaengigen Sequenzen, die SS-RARE-Sequenz, die T2w-single-shot-fast-spin-echo- (SSFSE) und die 3D-FSE-Sequenz spezifische Vor- und Nachteile. Die SS-RARE-Sequenz ist aufgrund der sehr kurzen Messzeit bei

  9. SENSITIVITY OF ENDOSCOPIC ULTRASOUND, MULTIDETECTOR COMPUTER TOMOGRAPHY AND MAGNETIC RESONANCE CHOLANGIOPANCREATOGRAPHY IN THE DIAGNOSIS OF PANCREAS DIVISUM: A TERTIARY CENTER EXPERIENCE

    Science.gov (United States)

    Kushnir, Vladimir M.; Wani, Sachin B.; Fowler, Kathryn; Menias, Christine; Varma, Rakesh; Narra, Vamsi; Hovis, Christine; Murad, Faris; Mullady, Daniel; Jonnalagadda, Sreenivasa S.; Early, Dayna S.; Edmundowicz, Steven A.; Azar, Riad R.

    2014-01-01

    OBJECTIVES There are limited data comparing imaging modalities in the diagnosis of pancreas divisum. We aimed to: 1. Evaluate the sensitivity of endoscopic ultrasound (EUS), magnetic resonance cholangiopancreatography (MRCP) and multi-detector computed tomography (MDCT) for pancreas divisum. 2. Assess interobserver agreement (IOA) among expert radiologists for detecting pancreas divisum on MDCT and MRCP. METHODS For this retrospective cohort study, we identified 45 consecutive patients with pancreaticobiliary symptoms and pancreas divisum established by endoscopic retrograde pancreatography (ERP) who underwent EUS and cross-sectional imaging. The control group was composed of patients without pancreas divisum who underwent ERP and cross-sectional imaging. RESULTS The sensitivity of EUS for pancreas divisum was 86.7%, significantly higher than sensitivity reported in the medical records for MDCT (15.5%) or MRCP (60%) [ppancreas divisum; IOA was moderate (қ=0.43). CONCLUSIONS EUS is a sensitive test for diagnosing pancreas divisum and is superior to MDCT and MRCP. Review of MDCT studies by expert radiologists substantially raises its sensitivity for pancreas divisum. PMID:23211370

  10. Biliary anatomy in potential right hepatic lobe living donor liver transplantation (LDLT): The utility of CT cholangiography in the setting of inconclusive MRCP

    International Nuclear Information System (INIS)

    McSweeney, Sean E.; Kim, Tae Kyoung; Jang, Hyun-Jung; Khalili, Korosh

    2012-01-01

    Objective: To determine the utility of CT cholangiography (CT-Ch) in preoperative evaluation of the biliary anatomy of living-donor liver transplantation (LDLT) donors when magnetic resonance cholangiopancreatography (MRCP) is inconclusive. Materials and methods: Over a 2-year period, 22 potential living liver donors underwent contrast-enhanced CT-Ch for preoperative evaluating biliary anatomy due to inconclusive results on MRCP and subsequently donated their right hepatic lobe. Nineteen of them underwent intraoperative cholangiography and were included in this study. Two radiologists retrospectively reviewed both MRCP and CT-Ch with 1-month interval and documented the types of bile duct branching patterns and visualization score of intrahepatic bile ducts (4-point scale). Results: There were no complications associated with CT-Ch examinations. CT-Ch was concordant with the reference standard in 18/19 (95%) including 7/8 typical branching type and 11/11 anomalous branching types. MRCP was concordant with the reference standard in 14/19 (74%) including 4/8 typical branching types and 10/11 anomalous branching types. The discordant case by CT-Ch was the identification of a tiny accessory right intrahepatic duct joining the common bile duct which was not visualized on intraoperative cholangiography. CT-Ch showed higher visualization score (mean, 3.9) than MRCP (mean, 2.6) (P < .001). Conclusion: CT-Ch can be effectively used for the depiction of the branching pattern of the bile duct at the hepatic hilum when MRCP is inconclusive.

  11. Diagnosis of mild chronic pancreatitis (Cambridge classification): comparative study using secretin injection-magnetic resonance cholangiopancreatography and endoscopic retrograde pancreatography.

    Science.gov (United States)

    Sai, Jin-Kan; Suyama, Masafumi; Kubokawa, Yoshihiro; Watanabe, Sumio

    2008-02-28

    To investigate the usefulness of secretin injection-MRCP for the diagnosis of mild chronic pancreatitis. Sixteen patients having mild chronic pancreatitis according to the Cambridge classification and 12 control subjects with no abnormal findings on the pancreatogram were examined for the diagnostic accuracy of secretin injection-MRCP regarding abnormal branch pancreatic ducts associated with mild chronic pancreatitis (Cambridge Classification), using endoscopic retrograde cholangiopancreatography (ERCP) for comparison. The sensitivity and specificity for abnormal branch pancreatic ducts determined by two reviewers were respectively 55%-63% and 75%-83% in the head, 57%-64% and 82%-83% in the body, and 44%-44% and 72%-76% in the tail of the pancreas. The sensitivity and specificity for mild chronic pancreatitis were 56%-63% and 92%-92%, respectively. Interobserver agreement (kappa statistics) concerning the diagnosis of an abnormal branch pancreatic duct and of mild chronic pancreatitis was good to excellent. Secretin injection-MRCP might be useful for the diagnosis of mild chronic pancreatitis.

  12. Fast MR imaging for evaluating the pancreaticobiliary system

    International Nuclear Information System (INIS)

    Takehara, Yasuo

    1999-01-01

    Due to physiological movement clinical MR applications for abdominal organs got off to a very slow start compared to MR imaging of other organs. However, with recent cutting-edge hardware technologies such as high performance gradient systems and phased-array capability, as well as software innovations including short TR fast spoiled gradient recalled acquisition in the steady state (GRASS), snapshot imaging such as single shot fast spin echo sequence (SSFSE) and echo planar imaging (EPI), scan times have been further reduced to make breath-hold imaging clinically viable and to enable semi-fluoroscopic, kinematic imaging recognition. The elimination of physiological motion has contributed to the significant improvement in image quality, or more specifically, the physiological motion that had long been problematic has been turned into a source of physiological information about pancreaticobiliary pathologies. In this article, the author reviewed the current status of fast MR technologies for examining pancreaticobiliary pathologies, stressing the functional and physiological aspects of the corresponding anatomy. The technologies included secretin MRCP, which became a powerful tool when combined with kinematic imaging

  13. Mucinous cystic neoplasms and serous cystadenomas arising in the body-tail of the pancreas: MR imaging characterization

    Energy Technology Data Exchange (ETDEWEB)

    Manfredi, Riccardo; Ventriglia, Anna; Mehrabi, Sara; Boninsegna, Enrico; Pozzi Mucelli, Roberto [University of Verona, Department of Radiology, Verona (Italy); Mantovani, William [Provincial Health Services, Department of Public Health and Prevention, Trento (Italy); Zamboni, Giuseppe [University of Verona, Department of Pathology, Verona (Italy); Salvia, Roberto [University of Verona, Department of Surgery, Verona (Italy)

    2015-04-01

    To identify magnetic resonance (MR)/MR cholangiopancreatography (MRCP) imaging signs helpful in the differential diagnosis between serous cystadenomas (SCAs) and mucinous cystic neoplasms (MCNs), arising from the body/tail of the pancreas. This retrospective study had institutional review board approval and informed consent was waived. Fifty-three patients with non-communicating cystic pancreatic neoplasm of the body/tail, undergoing MR/MRCP, were included. Qualitative image analysis assessed the macroscopic pattern, number of cysts, presence of central scar, contrast enhancement of peripheral wall, and mural nodules. Quantitative analysis assessed the maximum diameter of the neoplasm, thickness of the peripheral wall, and calibre of the upstream main pancreatic duct. Histopathology results revealed that 27/53 (51 %) were SCAs, 26/53 (49 %) were MCNs. Microcystic pattern was observed in 88.2 % of SCAs and 11.8 % of MCNs; macrocystic pattern was observed in 90.5 % of MCNs and 9.5 % of SCAs (p < 0.0001). Central scar was detected in 29.6 % of SCAs and no MCNs (p = 0.003). Contrast enhancement of the peripheral wall was evident in 99.5 % of MCNs and 11.5 % of SCAs (p < 0.0001); mural nodules were depicted in 94.1 % of MCNs and 5.9 % of SCAs (p < 0.0001). Median maximum diameter was 54 mm for MCNs, 32 mm for SCAs (p = 0.001); median wall thickness was 4 mm for MCNs, 2 mm for SCAs (p < 0.0001). Macrocystic pattern, enhancement of a peripheral wall and mural nodules are suggestive of MCNs; whereas microcystic pattern, lack of peripheral wall and central scar are suggestive of SCAs. (orig.)

  14. Single dose oral ranitidine improves MRCP image quality: a double-blind study

    International Nuclear Information System (INIS)

    Bowes, M.T.; Martin, D.F.; Melling, A.; Roberts, D.; Laasch, H.-U.; Sukumar, S.; Morris, J.

    2007-01-01

    Aim: To investigate the possibility of whether a single 300 mg dose of ranitidine given orally 2-3 h before magnetic resonance cholangiopancreatography (MRCP) could reduce the signal from the stomach and duodenum, and thus increase the conspicuousness of the biliary tree. Materials and methods: Thirty-five volunteers (22 female, 13 male), (age range 21-50) were underwent MRCP in a double-blind, placebo-controlled, randomized, crossover trial on a Philips Intera 1.5 T machine using a phased array surface coil. Imaging was carried out in the coronal oblique plane. Six 40 mm sections were acquired at varying angles to delineate the biliary tree and pancreatic duct. The 70 examinations were blindly scored by three consultants experienced in cholangiography. Results: After ranitidine administration there was a significant decrease in signal from the stomach (mean = 17.7, p = 0.0005, CI 10, 25.3) and duodenum (mean = 18.4, p = 0.0005, 95%CI 9.6, 27.1) with a significant increase in conspicuousness of the distal common duct (mean = 7.7, p = 0.033, 95%CI 0.7, 14.7) and proximal common duct (mean = 8.7, p = 0.010 CI 2.2, 15.2). There were no adverse effects. Conclusion: Oral ranitidine is a cheap and effective agent to decrease signal from the upper gastrointestinal tract and to improve visibility of the biliary tree

  15. Secretin-stimulating MRCP in patients with pancreatobiliary maljunction and occult pancreatobiliary reflux: direct demonstration of pancreatobiliary reflux

    Energy Technology Data Exchange (ETDEWEB)

    Motosugi, Utaroh; Ichikawa, Tomoaki; Araki, Tsutomu [University of Yamanashi, Department of Radiology, Chuo-shi, Yamanashi (Japan); Kitahara, Fumiaki; Sato, Tadashi [University of Yamanashi, First Department of Internal Medicine, Chuo-shi, Yamanashi (Japan); Itakura, Jun; Fujii, Hideki [University of Yamanashi, First Department of Surgery, Chuo-shi, Yamanashi (Japan)

    2007-09-15

    We propose the hypothesis that the enlargement of the common bile duct (CBD) or gallbladder (GB) that is occasionally demonstrated on magnetic resonance cholangiopancreatography (MRCP) after secretin stimulation is caused by pancreatobiliary reflux. Recently, occult pancreatobiliary reflux (OPR) has been demonstrated in patients without morphological pancreatobiliary maljunction (MPBM). The aim of this study was to evaluate the efficacy of secretin-stimulating MRCP (SMRCP) in the diagnosis of pancreatobiliary reflux. The study included 14 patients with MPBM and 32 patients with a normal pancreatobiliary junction. OPR was evaluated by bile collection and diagnosed in seven of the 32 patients. All the patients underwent SMRCP; the related findings were considered positive when enlargement of the CBD or GB was observed. Positive findings on SMRCP were observed in all MPBM patients. In the patients with normal pancreatobiliary junction, there was significant difference between the mean amylase levels in the patients with positive and negative SMRCP findings (mean, 4,755.7 and 29.7 IU/l). The sensitivity and specificity of SMRCP for diagnosing OPR was 85.7% and 68.0%, respectively. SMRCP provides a non invasive method for excluding PBR and can identify patients who could benefit from bile duct sampling to diagnose OPR. (orig.)

  16. Diagnostic value of high strength MRCP in the obstructive jaundice

    International Nuclear Information System (INIS)

    Yang Yang; Dong Yuhai; Yin Jie; Lv Guoyi

    2007-01-01

    Objective: To evaluate the diagnostic value of high strength MRCP in patients with obstructive jaundice. Methods: Routine MRI and MRCP examination on 161 patients with obstructive jaundice were carded out with 1.5T Siemens super-conductive magnetic resonance machine. Of them, 103 cases were benign lesions and 58 were malignant after surgical and ERCP pathological confirmation. Results: The diagnostic accuracy of MRCP was 100%, with the qualitative diagnostic accuracy at 90.2%. Conclusion: MRCP was the best method in diagnosing patients with obstructive jaundice, the concerned performances of MRCP could provide the dependable basis for surgical operation project. (authors)

  17. Magnetic resonance cholangiographic (MRCP) features of ischemic-type biliary lesions (ITBL). A case-control study; Magnetresonanz-Cholangiografie (MRCP) bei Patienten mit Ischemic-Type Biliary Lesions (ITBL). Eine Fall-Kontroll-Studie

    Energy Technology Data Exchange (ETDEWEB)

    Collettini, F.; Kroencke, T.J.; Renz, D.M.; Bucourt, M. de; Poellinger, A. [Charite, Berlin (Germany). Klinik fuer Radiologie; Heidenhain, C.; Neuhaus, P. [Charite, Berlin (Germany). Klinik fuer Allgemein-, Visceral- und Transplantationschirurgie CVK

    2011-08-15

    Purpose: To evaluate the spectrum of MR cholangiography (MRCP) features of ischemic-type biliary lesions (ITBL) after orthotopic liver transplantation (OLT). Materials and Methods: 30 patients (16 m, 14 f) with an average age of 52 years (9 - 69 y) were examined in two 1.5 MR units using breath-hold 2D-SS-FSE-sequences and 3D-MRCP sequences. 20 of the 30 patients had an established ITBL, and the remaining 10 patients were post-OLT controls. MRCPs were evaluated independently by two experienced radiologists that were blinded to the clinical history as well as the results of other imaging modalities. All images were analyzed for the presence of 16 different pathological features. Differences between ITBL patients and controls were analyzed using the Mann-Whitney-U Test. Inter-rater variability was tested using the Cohen's Kappa test. Results: Abnormal findings of bile ducts were seen in all patients. The most common findings were (in percentage for reader 1/2) intrahepatic bile duct dilatation (95 %/95 %) and extrahepatic bile duct stenoses (95 %/85 %), followed by intrahepatic main duct stenoses (90 %/95 %) and segmental duct stenoses (85 %/85 %). Differences between ITBL patients and controls were significant for most of the analyzed features (Mann-Whitney-U test, p < 0.05). For 12 of 16 features, there was substantial or almost perfect agreement (K = 0.61 - 1.00), for 2 of 16 features moderate agreement (K = 0.41- 0.60) and for 2 of 16 features fair agreement (K < 0.40). Conclusion: In patients with ITBL, MR cholangiography reveals characteristic features that may allow differentiation from other biliary complications after liver transplantation. (orig.)

  18. [Comparison of 2D and 3D sequences for MRCP. Clinical value of the different techniques].

    Science.gov (United States)

    Wallnoefer, A M; Herrmann, K A; Beuers, U; Zech, C J; Gourtsoyianni, S; Reiser, M F; Schoenberg, S O

    2005-11-01

    Magnetic resonance cholangio-pancreaticograpy (MRCP) is a non-invasive imaging modality of the pancreatico-biliary system which plays an increasingly important role in the clinical and diagnostic workup of patients with biliary or pancreatic diseases. The present review is designed to give an overview of the currently available and appropriate sequences, their technical background, as well as new developments and their relevance to the various clinical issues and challenges. The impact of the latest technical innovations, such as integrated parallel imaging techniques and navigator-based respiratory triggering, on the diagnostic capacities of MRCP is discussed. In this context, the individual value of RARE, T2w single shot turbo/fast spin echo (SSFSE) and the recently introduced 3D T2w turbo/fast spin echo sequences (T2w 3D-T/FSE) is reviewed. RARE imaging may be preferred in severely ill patients with limitations in cooperation, SSFSE is particularly effective in differentiating benign and malignant stenosis, and 3D-FSE offers additional advantages in the detection of small biliary concrements.

  19. Magnetic resonance cholangiographic (MRCP) features of ischemic-type biliary lesions (ITBL). A case-control study

    International Nuclear Information System (INIS)

    Collettini, F.; Kroencke, T.J.; Renz, D.M.; Bucourt, M. de; Poellinger, A.; Heidenhain, C.; Neuhaus, P.

    2011-01-01

    Purpose: To evaluate the spectrum of MR cholangiography (MRCP) features of ischemic-type biliary lesions (ITBL) after orthotopic liver transplantation (OLT). Materials and Methods: 30 patients (16 m, 14 f) with an average age of 52 years (9 - 69 y) were examined in two 1.5 MR units using breath-hold 2D-SS-FSE-sequences and 3D-MRCP sequences. 20 of the 30 patients had an established ITBL, and the remaining 10 patients were post-OLT controls. MRCPs were evaluated independently by two experienced radiologists that were blinded to the clinical history as well as the results of other imaging modalities. All images were analyzed for the presence of 16 different pathological features. Differences between ITBL patients and controls were analyzed using the Mann-Whitney-U Test. Inter-rater variability was tested using the Cohen's Kappa test. Results: Abnormal findings of bile ducts were seen in all patients. The most common findings were (in percentage for reader 1/2) intrahepatic bile duct dilatation (95 %/95 %) and extrahepatic bile duct stenoses (95 %/85 %), followed by intrahepatic main duct stenoses (90 %/95 %) and segmental duct stenoses (85 %/85 %). Differences between ITBL patients and controls were significant for most of the analyzed features (Mann-Whitney-U test, p < 0.05). For 12 of 16 features, there was substantial or almost perfect agreement (K = 0.61 - 1.00), for 2 of 16 features moderate agreement (K = 0.41- 0.60) and for 2 of 16 features fair agreement (K < 0.40). Conclusion: In patients with ITBL, MR cholangiography reveals characteristic features that may allow differentiation from other biliary complications after liver transplantation. (orig.)

  20. Magnetic resonance cholangiopancreaticography as a diagnostic tool for common bile duct stones - A comparison with ERCP and clinical follow-up

    NARCIS (Netherlands)

    Kats, J; Kraai, M; Dijkstra, AJ; Koster, K; ter Borg, F; Hazenberg, HJA; Schattenkerk, ME; des Plantes, BGZ; Eddes, EH

    2003-01-01

    Background/Aims: The diagnostic potential of magnetic resonance cholangiopancreaticography (MRCP) has improved as a result of evolving technique. MRCP has the advantage of negligible morbidity and mortality in contrast to endoscopic retrograde cholangiopancreatography (ERCP). This study was

  1. Magnetic Resonance Cholangiopancreatography (MRCP)

    Science.gov (United States)

    ... radio waves and a computer to evaluate the liver, gallbladder, bile ducts, pancreas and pancreatic duct for disease. It is ... of the hepatobiliary and pancreatic systems, including the liver, gallbladder, bile ducts, pancreas and pancreatic duct . Magnetic resonance imaging (MRI) ...

  2. Single-Shot MR Spectroscopic Imaging with Partial Parallel Imaging

    Science.gov (United States)

    Posse, Stefan; Otazo, Ricardo; Tsai, Shang-Yueh; Yoshimoto, Akio Ernesto; Lin, Fa-Hsuan

    2010-01-01

    An MR spectroscopic imaging (MRSI) pulse sequence based on Proton-Echo-Planar-Spectroscopic-Imaging (PEPSI) is introduced that measures 2-dimensional metabolite maps in a single excitation. Echo-planar spatial-spectral encoding was combined with interleaved phase encoding and parallel imaging using SENSE to reconstruct absorption mode spectra. The symmetrical k-space trajectory compensates phase errors due to convolution of spatial and spectral encoding. Single-shot MRSI at short TE was evaluated in phantoms and in vivo on a 3 T whole body scanner equipped with 12-channel array coil. Four-step interleaved phase encoding and 4-fold SENSE acceleration were used to encode a 16×16 spatial matrix with 390 Hz spectral width. Comparison with conventional PEPSI and PEPSI with 4-fold SENSE acceleration demonstrated comparable sensitivity per unit time when taking into account g-factor related noise increases and differences in sampling efficiency. LCModel fitting enabled quantification of Inositol, Choline, Creatine and NAA in vivo with concentration values in the ranges measured with conventional PEPSI and SENSE-accelerated PEPSI. Cramer-Rao lower bounds were comparable to those obtained with conventional SENSE-accelerated PEPSI at the same voxel size and measurement time. This single-shot MRSI method is therefore suitable for applications that require high temporal resolution to monitor temporal dynamics or to reduce sensitivity to tissue movement. PMID:19097245

  3. Imaging of the intrabiliary rupture of hepatic hydatid cysts

    International Nuclear Information System (INIS)

    Liu Wenya; Wang Jian; Liu Xinli

    2009-01-01

    Objective: To discuss the imaging features of ultrasonography (USG), CT /CT cholangiography (CTC), MR/MR cholangiopancreatography (MRCP) and endoscopic retrograde cholangiopancreatography (ERCP) of the hepatic hydatid cysts ruptured into biliary duct, and to evaluate the diagnostic efficacy of different modalities. Methods: Fifty one cases of hepatic hydatid cysts with intrabiliary rupture were divided into 4 groups according to imaging modality used to study these cases. 46 cases, 41 cases, 35 cases and 14 cases were examined by USG, CT, MRCP and ERCP respectively. Comparison of the imaging findings from different imaging modalities with surgical results were made to evaluate the efficacy of each imaging modality. Analysis of χ 2 were performed for the positive predictive value among the 4 groups. Results: The positive predictive values of these four methods in diagnosing the intrabiliary rupture of liver hydatid cyst were 67.4% (31/46), 80.5% (33/41), 94.3% (33/35)and respectively (χ 2 =13.1370, P<0.05). There were statistical difference between USG and 100.0% (14/14) MRCP (P<0.0084). The direct manifestations of intrabiliary rupture of hepatic hydatid cysts on USG, CT, MRCP and ERCP were as following: (1) Communication break point was seen in 3/46,3/41,9/35 and 13/14 eases respectively; (2) Increased biliary density due to the presence of membrane of echinococcus cysts and daughter cysts were seen in 5/46, 6/41,6/35 and 8/14 cases respectively; (3) Lesions adjacent to bile duct, gall bladder wall thickening, and/or interruption of bile duct, remote biliary dilatation were seen in 24/46, 26/41, 31/35 and 8/14 of cases respectively. Indirect signs included: (1) Cyst collapse, increased cyst fluid density were seen in 30/46, 33/41, 27/35 and 0/14 of cases respectively; (2) Detached membrane signs were seen in 21/46, 24/41,22/35 and 0/14; (3) Dilatation of adjacent hepatic bile duct were seen in 30/46, 29/41, 34/35 and 6/14 of cases respectively. Conclusions: Both

  4. Detection of common bile duct stones: comparison between endoscopic ultrasonography, magnetic resonance cholangiography, and helical-computed-tomographic cholangiography

    International Nuclear Information System (INIS)

    Kondo, Shintaro; Isayama, Hiroyuki; Akahane, Masaaki; Toda, Nobuo; Sasahira, Naoki; Nakai, Yosuke; Yamamoto, Natsuyo; Hirano, Kenji; Komatsu, Yutaka; Tada, Minoru; Yoshida, Haruhiko; Kawabe, Takao; Ohtomo, Kuni; Omata, Masao

    2005-01-01

    Objectives: New modalities, namely, endoscopic ultrasonography (EUS), magnetic resonance cholangiopancreatography (MRCP), and helical computed-tomographic cholangiography (HCT-C), have been introduced recently for the detection of common bile duct (CBD) stones and shown improved detectability compared to conventional ultrasound or computed tomography. We conducted this study to compare the diagnostic ability of EUS, MRCP, and HCT-C in patients with suspected choledocholithiasis. Methods: Twenty-eight patients clinically suspected of having CBD stones were enrolled, excluding those with cholangitis or a definite history of choledocholithiasis. Each patient underwent EUS, MRCP, and HCT-C prior to endoscopic retrograde cholangio-pancreatography (ERCP), the result of which served as the diagnostic gold standard. Results: CBD stones were detected in 24 (86%) of 28 patients by ERCP/IDUS. The sensitivity of EUS, MRCP, and HCT-C was 100%, 88%, and 88%, respectively. False negative cases for MRCP and HCT-C had a CBD stone smaller than 5 mm in diameter. No serious complications occurred while one patient complained of itching in the eyelids after the infusion of contrast agent on HCT-C. Conclusions: When examination can be scheduled, MRCP or HCT-C will be the first choice because they were less invasive than EUS. MRCP and HCT-C had similar detectability but the former may be preferable considering the possibility of allergic reaction in the latter. When MRCP is negative, EUS is recommended to check for small CBD stones

  5. Usefulness of magnetic resonance cholangiography in the diagnosis of biliary tract lesions in patients with suspected complication following cholecystectomy; Valor da colangiopancreatografia por ressonancia magnetica no diagnostico de lesoes das vias biliares em pacientes com suspeita de complicacao pos-colecistectomia

    Energy Technology Data Exchange (ETDEWEB)

    Cecin, Alexandre de Oliveira [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil); Goldman, Suzan Menasce; Caetano, Simone; Rosas, George de Queiroz; Coelho, Rafael Darahem de Souza [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. de Diagnostico por Imagem; Lobo, Edson Jose [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. de Gastroenterologia Cirurgica; Abdalla, Nitamar; Szejnfeld, Jacob [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. de Diagnostico por Imagem

    2005-01-15

    Objective: to determine the usefulness of magnetic resonance cholangiopancreatography (MRCP) in the diagnoses of bile duct injuries following cholecystectomy. Material and method: MRCP was retrospectively evaluated in 40 patients with suspected bile duct injury after laparoscopic or conventional cholecystectomy. Eight of these patients had been submitted to biliary reconstruction. All patients were symptomatic (jaundice, fever and chills, weight loss and abdominal pain). The scans were independently reviewed by two radiologists. The results were confirmed by surgery, percutaneous drainage, endoscopic retrograde cholangiopancreatography and clinical follow-up. The level and severity of bile duct injury were rated according to the Bismuth classification. Results: in a total of 40 symptomatic patients, 10 (25%) had normal findings on MRCP; Postoperative complications were seen in 29 (72.5%) patients, seven of them with more than one finding. Pancreatic head neoplasia was diagnoses in one patient. The most frequent finding was sclerosing (41.4%) followed by biliary duct stenosis (34.5%), residual or recurrent biliary stones (31.0%) and fluid collections (17.2%). The images obtained by MRCP were considered of good quality. Conclusion: MRCP is an effective method for the evaluation of patients with suspected postcholecystectomy biliary tract complications. (author)

  6. Usefulness of magnetic resonance cholangiography in the diagnosis of biliary tract lesions in patients with suspected complication following cholecystectomy

    International Nuclear Information System (INIS)

    Cecin, Alexandre de Oliveira; Goldman, Suzan Menasce; Caetano, Simone; Rosas, George de Queiroz; Coelho, Rafael Darahem de Souza; Lobo, Edson Jose; Abdalla, Nitamar; Szejnfeld, Jacob

    2005-01-01

    Objective: to determine the usefulness of magnetic resonance cholangiopancreatography (MRCP) in the diagnoses of bile duct injuries following cholecystectomy. Material and method: MRCP was retrospectively evaluated in 40 patients with suspected bile duct injury after laparoscopic or conventional cholecystectomy. Eight of these patients had been submitted to biliary reconstruction. All patients were symptomatic (jaundice, fever and chills, weight loss and abdominal pain). The scans were independently reviewed by two radiologists. The results were confirmed by surgery, percutaneous drainage, endoscopic retrograde cholangiopancreatography and clinical follow-up. The level and severity of bile duct injury were rated according to the Bismuth classification. Results: in a total of 40 symptomatic patients, 10 (25%) had normal findings on MRCP; Postoperative complications were seen in 29 (72.5%) patients, seven of them with more than one finding. Pancreatic head neoplasia was diagnoses in one patient. The most frequent finding was sclerosing (41.4%) followed by biliary duct stenosis (34.5%), residual or recurrent biliary stones (31.0%) and fluid collections (17.2%). The images obtained by MRCP were considered of good quality. Conclusion: MRCP is an effective method for the evaluation of patients with suspected postcholecystectomy biliary tract complications. (author)

  7. Acute interstitial edematous pancreatitis: Findings on non-enhanced MR imaging

    Science.gov (United States)

    Zhang, Xiao-Ming; Feng, Zhi-Song; Zhao, Qiong-Hui; Xiao, Chun-Ming; Mitchell, Donald G; Shu, Jian; Zeng, Nan-Lin; Xu, Xiao-Xue; Lei, Jun-Yang; Tian, Xiao-Bing

    2006-01-01

    AIM: To study the appearances of acute interstitial edematous pancreatitis (IEP) on non-enhanced MR imaging. METHODS: A total of 53 patients with IEP diagnosed by clinical features and laboratory findings were underwent MR imaging. MR imaging sequences included fast spoiled gradient echo (FSPGR) fat saturation axial T1-weighted imaging, gradient echo T1-weighted (in phase), single shot fast spin echo (SSFSE) T2-weighted, respiratory triggered (R-T) T2-weighted with fat saturation, and MR cholangiopancreatography. Using the MR severity score index, pancreatitis was graded as mild (0-2 points), moderate (3-6 points) and severe (7-10 points). RESULTS: Among the 53 patients, IEP was graded as mild in 37 patients and as moderate in 16 patients. Forty-seven of 53 (89%) patients had at least one abnormality on MR images. Pancreas was hypointense relative to liver on FSPGR T1-weighted images in 18.9% of patients, and hyperintense in 25% and 30% on SSFSE T2-weighted and R-T T2-weighted images, respectively. The prevalences of the findings of IEP on R-T T2-weighted images were, respectively, 85% for pancreatic fascial plane, 77% for left renal fascial plane, 55% for peripancreatic fat stranding, 42% for right renal fascial plane, 45% for perivascular fluid, 40% for thickened pancreatic lobular septum and 25% for peripancreatic fluid, which were markedly higher than those on in-phase or SSFSE T2-weighted images (P fluid. R-T T2-weighted imaging is more sensitive than in-phase and SSFSE T2-weighted imaging for depicting IEP. PMID:17007053

  8. Santorinicele: secretin-enhanced magnetic resonance cholangiopancreatography findings before and after minor papilla sphincterotomy

    Energy Technology Data Exchange (ETDEWEB)

    Boninsegna, Enrico; Manfredi, Riccardo; Ventriglia, Anna; Negrelli, Riccardo; Pedrinolla, Beatrice; Mehrabi, Sara; Pozzi Mucelli, Roberto [University of Verona, Department of Radiology - Policlinico G.B. Rossi, Verona (Italy); Gabbrielli, Armando [University of Verona, Department of Medicine - Policlinico G.B. Rossi, Verona (Italy)

    2015-08-15

    To evaluate secretin-enhanced MRCP (S-MRCP) findings of patients with pancreas divisum and Santorinicele, before and after minor papilla sphincterotomy. S-MRCP examinations of 519 patients with suspected pancreatic disease were included. Size of the main pancreatic duct, presence and calibre of Santorinicele were evaluated. Duodenal filling was assessed on dynamic images. After sphincterotomy the same parameters and the clinical findings were re-evaluated. Pancreas divisum was depicted in 55/519 patients (11 %) by MRCP and an additional 26/519 by S-MRCP (total 81/519, 16 %). Santorinicele was detected in 7/81 patients (8.6 %) with pancreas divisum by MRCP and an additional 20/81 by S-MRCP (total 27/81, 33 %). Dorsal duct in patients with Santorinicele was significantly larger in the head compared with patients with only pancreas divisum (p < 0.01), in basal conditions (average 2.4 versus 1.9 mm) and after secretin administration (average 3.0 versus 2.4 mm). Duodenal filling was impaired in 11/27 patients (41 %) with Santorinicele. After sphincterotomy significant reduction in size of Santorinicele (-33 %) and dorsal duct (-17 %), increase of pancreatic juice and symptoms improvement were observed. Secretin administration increases the accuracy of MRCP in detecting Santorinicele and demonstrates the impaired duodenal filling. S-MRCP is useful to assess results of sphincterotomy. (orig.)

  9. Anterior chamber configuration in patients with glaucoma: MR gonioscopy evaluation with half-Fourier single-shot RARE sequence and microscopy coil.

    Science.gov (United States)

    Tanitame, Keizo; Sasaki, Ko; Sone, Takashi; Uyama, Shinji; Sumida, Masumi; Ichiki, Toshio; Ito, Katsuhide

    2008-10-01

    The purpose of the study was to determine the accuracy of half-Fourier single-shot rapid acquisition with relaxation enhancement high-spatial-resolution magnetic resonance (MR) imaging performed with a microscopy coil in the diagnosis of narrow anterior chamber angle in patients with glaucoma. Slit-lamp biomicroscopy served as the reference standard. The institutional review board approved this study, and written informed consent was obtained from the 20 recruited patients. There was excellent agreement between MR gonioscopy and slit-lamp biomicroscopy in the classification of anterior chamber angles as narrow or open (kappa = 0.89 [95% confidence interval: 0.69, 1.10]). MR gonioscopy has substantial potential as a technique used to evaluate glaucoma. (c) RSNA, 2008.

  10. Imaging diagnosis of intraductal papillary mucinous tumor of the pancreas

    International Nuclear Information System (INIS)

    Zhang Huimao; Lai Ying; Yang Shuqin; Yang Haishan; Murakami, K.

    2005-01-01

    Objective: To explore the diagnostic value of intraductal papillary mucinous tumor (IPMT) of the pancreas, and to assess its clinical and characteristic radiological features. Methods: Thirty-six cases with IPMT who underwent CT and MRI with plain and contrast enhancement before operation were reviewed. The clinical presentation and characteristic imaging findings of main duct type (8 cases) and branch duct type (28 cases) were retrospectively reviewed. Results: Typical imaging findings of main duct type were segmental or diffuse dilation of MPD (diameter was over 9 mm) with enhanced mural nodules after contrast medium administration. MR cholangiopancreatography (MRCP) showed dilation of MPD with flat/nodule filling defects in 4 cases and MPD dilatation in the head side in 2 cases. Branch duct type was more frequently located in the head or uncinate. Typical imaging findings of branch duct type were unilocular or multilocular cystic tumors with septa, mural nodules, and MPD dilatation. MRCP showed septa in 24 cases, filling defects in 15 cases, and MPD dilatation in 8 cases. Communication between the cystic lesion and the MPD was demonstrated in 19 cases by MRCP. Conclusion: It is extremely important to accurately make the diagnosis of IPMT for planning the surgical strategy. MRCP is a noninvasive and useful method in detecting and making definite diagnosis of IPMT. (authors)

  11. Evaluation of date syrup as an oral negative contrast agent for MRCP.

    Science.gov (United States)

    Govindarajan, Arunkumar; Lakshmanan, Prakash Manikka; Sarawagi, Radha; Prabhakaran, Velu

    2014-11-01

    The purpose of this study was to compare the in vitro effects of date syrup with those of other contrast agents by qualitative and quantitative analysis and in vivo evaluation of the use of date syrup to improve the quality of MRCP images. Phantoms containing date syrup, ferumoxsil, pineapple juice, and water were imaged by 1.5-T MRI with T2-weighted and MRCP sequences, and signal-to-noise ratios were calculated. Biochemical analysis of date syrup was performed to find the nature of iron in it, and the iron content was quantified by energy-dispersive x-ray spectroscopy. Sixty patients underwent MRCP before and 30 minutes after ingestion of 100 mL of date syrup. Unenhanced and contrast-enhanced images were scored for gastrointestinal tract signal suppression and visualization of various pancreaticobiliary structures. In vitro evaluation showed that images obtained with date syrup had a signal-to-noise ratio comparable to that of images obtained with ferumoxsil in T2-weighted and MRCP sequences. The iron concentration in date syrup was 2.6 mg/dL, and it was in ferric form. Images obtained after oral contrast administration had statistically significant improvement in gastrointestinal tract signal suppression (p Date syrup can be used as a negative oral contrast agent for gastrointestinal tract signal suppression during MRCP and for improving visualization of various pancreaticobiliary structures.

  12. The diagnostic value of MRI and MRCP in congenital duct cysts and complications

    International Nuclear Information System (INIS)

    Xiao Fang; Huang Suiqiao; Hu Tao

    2009-01-01

    Objective: To investigate the value of MRI and MRCP in diagnosis of congenital duct cysts and their complications. Methods: The MRI and MRCP of 29 cases of congenital duct cyst verified by pathological findings were analyzed retrospectively. Results: In 29 cases of Congenital choledochocele, 10 of which are type lb and 7 were Ic, appearing as the focal choledochal ecstasis, which were connected with the bile duct tree and displayed by MRCP. 10 cases were type IV and 2 are type V, appearing as the multiple cholangiectasis extrahepaticly and/or intrahepaticly and displayed by MRCP as the multiple cystoid with different sizes. There were 7 cases with complication of calculus, 4 in type Ib and 3 in type IV, appearing as single or multiple non-enhanced lesion with clear border. There were 3 cases with complication of tumors, 1 cholangiocarcinoma in type IV and type V respectively, appearing as the enhanced nodus within the wall of dilatant bile duct, 1 gallbladder carcinoma in type lb with multiple liver metastasis. The interruption of distal choledochocele was demonstrated in the complication of biliary atresia in 1 of type V. There was pancreatitis in 1 of type IV. The diagnosis and typing of choledochocele can be accurately made by MRI combined with MRCP, and complications were easily and clearly showed. The accuracy rate for location of choledochocele was 100%. Conclusion: There is an important value for MRI and MRCP examination in diagnosis of congenital bile duct cysts and their complications. (authors)

  13. Imaging patients with 'post-cholecystectomy syndrome': an algorithmic approach

    International Nuclear Information System (INIS)

    Terhaar, O.A.; Abbas, S.; Thornton, F.J.; Duke, D.; O'Kelly, P.; Abdullah, K.; Varghese, J.C.; Lee, M.J.

    2005-01-01

    AIM: To assess the role of ultrasound (US), magnetic resonance cholangiopancreatography (MRCP) and liver function tests (LFTs) in the evaluation of selected patients presenting with late post-cholecystectomy syndrome (PCS) who were referred for endoscopic retrograde cholangiopancreatography (ERCP) MATERIALS AND METHODS: In a retrospective study a final group of 42 patients with PCS referred for diagnostic ERCP underwent MRCP and abdominal US. ERCP and MRCP images were assessed for bile duct diameters and the presence of strictures and stones. A common bile duct (CBD) diameter of <10 mm was considered normal, whereas ≥10 mm was considered abnormal on US. Findings were correlated to LFTs with contingency table results performed for single techniques and combination of methods. RESULTS: In total 14 stones and one stricture were seen. US had a high negative predictive value (86.4%). MRCP had a sensitivity of 100% and specificity of 88.0%. ERCP is the most accurate test but failed in 11 patients, five of whom had a stone. The accuracy of US and LFTs increases to 93.8% if test results agree in either negative or positive outcome. CONCLUSION: US and LFTs are first-line tests in PCS. If the CBD on US is ≥10 mm, but no cause is identified, MRCP should be performed. If US and LFTs are normal then MRCP is not necessary. The availability of LFTs raises the diagnostic value of imaging

  14. The role of multi-detector-row computed tomograph in the diagnosis of intraductal papillary-mucinous tumors of the pancreas in comparison to endoscopic retrograde pancreatography, endoscopic ultrasonography, magnetic resonance cholangiopancreatography

    International Nuclear Information System (INIS)

    Arikawa, Shunji; Uchida, Masafumi; Shinagawa, Masaharu

    2007-01-01

    Thirty patients with intraductal papillary-mucinous tumor (IPMT) of the pancreas underwent multidetector-row CT (MD-CT) in addition to endoscopic retrograde pancreatography (ERP), and, in 27 cases magnetic resonance cholangiopancreatography (MRCP) and endoscopic ultrasonography (EUS). The usefulness of MD-CT was investigated by comparing various imaging methods of the communication from the main pancreatic duct (MPD) to patulous/bulging papilla in addition to the indices for benign or malignant disease, the degree of dilation of the MPD, localization and size of cystic lesions, and presence or absence of neoplastic lesions, such as thickened walls and septa, intramural nodule, solid mass. With MD-CT, dilation of the MPD and localization and size of cystic lesions were accurately assessed, even in patients with obstruction of the main pancreatic duct in whom ERP was difficult to perform regardless of the presence or absence of massive amount of mucus. MD-CT with reconstructive imaging, such as multiplanar reformation (MPR) imaging and curred planar reformation (CPR) imaging, allowed us to assess communication with the MPD and patulous/bulging papilla easier than MRCP. In our study, MD-CT was useful in the evaluation of thickened walls and septa that are predictive factors of malignancy in IPMT. (author)

  15. [Value of MR imaging in the diagnosis of intraductal papillary neoplasm of the bile duct].

    Science.gov (United States)

    Song, Fengxiang; Zhou, Jun; Shi, Yuxin; Zeng, Mengsu; Zhou, Kangrong; Ding, Yuqin; Cao, Yingli; Zhou, Jianjun

    2015-01-01

    To analyze the value of MR imaging in diagnosis of intraductal papillary neoplasm of the bile duct (IPN-B). Fourteen patients with intraductal papillary neoplasms of the bile duct confirmed by surgical pathology were included in this study. The patients underwent MR routine plain scanning and enhancement scanning (including T1WI, T2WI with fat suppression, FALSH T1WI, and three-phase enhancement scanning), diffusion weighted imaging(DWI) and magnetic resonance cholangiopancreatography (MRCP) before operation. The imaging data were reviewed and analyzed retrospectively in comparison with the surgical and pathological results. In these patients, 7 cases had tumors located in the left lobe, 2 cases had tumors in both the left and right lobes, 2 cases in the hepatic hilum, 2 cases in the common bile duct, and 1 case in both the right lobe and the common bile duct. Solitary or multiple intraductal masses could be found in 12 cases, with 11 cases appeared as papillary masses and one case as flat mass. In the other two cases the tumor was not visible (one case had too many stones, and in another case the tumor was too small). The tumors in the 12 cases showed hypointensity on T1WI and hyperintensity on T2WI. On the dynamic contrast-enhanced MRI, 11 cases showed mild and one showed moderate enhancement in arterial phase, and all the cases showed mildly and gradually delayed enhancement. On DWI, the lesion areas showed high signal intensity in all the cases, and the ADC value of the tumor area (1.697×10(-3)mm(2)/s) was significantly lower than that of the normal bile (3.973×10(-3)mm(2)/s) (t = -10.94, P invisible tumors ). In the 3 cases with aneurysmal bile dilatation, the multiple directions of MRCP images helped to find the communication between the aneurysmal dilatation and the bile duct. All the cases showed significant proximal bile duct dilatation (the extent of dilatation >100%), and 9 cases also showed distal bile duct dilatation. Bile duct stones were noted in 6

  16. PLAB and UK graduates’ performance on MRCP(UK) and MRCGP examinations: data linkage study

    Science.gov (United States)

    Wakeford, Richard

    2014-01-01

    Objectives To assess whether international medical graduates passing the two examinations set by the Professional and Linguistic Assessments Board (PLAB1 and PLAB2) of the General Medical Council (GMC) are equivalent to UK graduates at the end of the first foundation year of medical training (F1), as the GMC requires, and if not, to assess what changes in the PLAB pass marks might produce equivalence. Design Data linkage of GMC PLAB performance data with data from the Royal Colleges of Physicians and the Royal College of General Practitioners on performance of PLAB graduates and UK graduates at the MRCP(UK) and MRCGP examinations. Setting Doctors in training for internal medicine or general practice in the United Kingdom. Participants 7829, 5135, and 4387 PLAB graduates on their first attempt at MRCP(UK) Part 1, Part 2, and PACES assessments from 2001 to 2012 compared with 18 532, 14 094, and 14 376 UK graduates taking the same assessments; 3160 PLAB1 graduates making their first attempt at the MRCGP AKT during 2007-12 compared with 14 235 UK graduates; and 1411 PLAB2 graduates making their first attempt at the MRCGP CSA during 2010-12 compared with 6935 UK graduates. Main outcome measures Performance at MRCP(UK) Part 1, Part 2, and PACES assessments, and MRCGP AKT and CSA assessments in relation to performance on PLAB1 and PLAB2 assessments, as well as to International English Language Testing System (IELTS) scores. MRCP(UK), MRCGP, and PLAB results were analysed as marks relative to the pass mark at the first attempt. Results PLAB1 marks were a valid predictor of MRCP(UK) Part 1, MRCP(UK) Part 2, and MRCGP AKT (r=0.521, 0.390, and 0.490; all PIELTS scores correlated significantly with later performance, multiple regression showing that the effect of PLAB1 (β=0.496) was much stronger than the effect of IELTS (β=0.086). Changes to PLAB pass marks that would result in international medical graduate and UK medical graduate equivalence were assessed in two

  17. PLAB and UK graduates' performance on MRCP(UK) and MRCGP examinations: data linkage study.

    Science.gov (United States)

    McManus, I C; Wakeford, Richard

    2014-04-17

    To assess whether international medical graduates passing the two examinations set by the Professional and Linguistic Assessments Board (PLAB1 and PLAB2) of the General Medical Council (GMC) are equivalent to UK graduates at the end of the first foundation year of medical training (F1), as the GMC requires, and if not, to assess what changes in the PLAB pass marks might produce equivalence. Data linkage of GMC PLAB performance data with data from the Royal Colleges of Physicians and the Royal College of General Practitioners on performance of PLAB graduates and UK graduates at the MRCP(UK) and MRCGP examinations. Doctors in training for internal medicine or general practice in the United Kingdom. 7829, 5135, and 4387 PLAB graduates on their first attempt at MRCP(UK) Part 1, Part 2, and PACES assessments from 2001 to 2012 compared with 18,532, 14,094, and 14,376 UK graduates taking the same assessments; 3160 PLAB1 graduates making their first attempt at the MRCGP AKT during 2007-12 compared with 14,235 UK graduates; and 1411 PLAB2 graduates making their first attempt at the MRCGP CSA during 2010-12 compared with 6935 UK graduates. Performance at MRCP(UK) Part 1, Part 2, and PACES assessments, and MRCGP AKT and CSA assessments in relation to performance on PLAB1 and PLAB2 assessments, as well as to International English Language Testing System (IELTS) scores. MRCP(UK), MRCGP, and PLAB results were analysed as marks relative to the pass mark at the first attempt. PLAB1 marks were a valid predictor of MRCP(UK) Part 1, MRCP(UK) Part 2, and MRCGP AKT (r=0.521, 0.390, and 0.490; all PIELTS scores correlated significantly with later performance, multiple regression showing that the effect of PLAB1 (β=0.496) was much stronger than the effect of IELTS (β=0.086). Changes to PLAB pass marks that would result in international medical graduate and UK medical graduate equivalence were assessed in two ways. Method 1 adjusted PLAB pass marks to equate median performance of PLAB

  18. Cardiac and vascular imaging with snapshot FLASH MR imaging

    International Nuclear Information System (INIS)

    Matthaei, D.; Haase, A.; Norris, D.; Leibfritz, D.; Henrich, D.; Duhmke, E.

    1989-01-01

    Acceleration of fast low-angle-shot (FLASH) MR imaging to about 200 msec measuring time on dedicated MR systems is called snapshot FLASH MR imaging. It snaps real-time series of MR images of the MR relaxation and of physiologic motions with nearly absent motion and susceptibility artifacts. Results in animals (4.7T) and human volunteers (2.0T) show plain vascular and cardiac snapshot FLASH MR images obtained as single shot, triggered reconstructed motion, or real-time films. The reduction of artifacts and the high resolution (triggered, three-dimensional moving heart images are possible) result in favorable applications in myocardial and great vascular disease

  19. Anatomic variants of the pancreatic duct and their clinical relevance: an MR-guided study in the general population

    International Nuclear Information System (INIS)

    Buelow, Robin; Thiel, Robert; Thamm, Patrick; Messner, Philip; Hosten, Norbert; Kuehn, Jens-Peter; Simon, Peter; Lerch, Markus M.; Mayerle, Julia; Voelzke, Henry

    2014-01-01

    To investigate the frequency of pancreatic duct (PD) variants and their effect on pancreatic exocrine function in a population-based study using non-invasive secretin-stimulated magnetic resonance cholangiopancreatography (sMRCP). Nine hundred and ninety-five volunteers, 457 women and 538 men, aged 51.9 ± 13.4 years, underwent navigator-triggered, T2-weighted, 3D turbo spin echo MRCP on a 1.5 T system after 1 unit/kg secretin administration. Two readers evaluated images for PD variants. Pancreatic exocrine function and morphological signs of chronic pancreatitis such as abnormalities of the main PD, side branch dilatation, and pancreatic cysts were evaluated and related to PD variants using a Kruskal-Wallis test and post hoc analysis. Of all sMRCP, 93.2 % were of diagnostic quality. Interobserver reliability for detection of PD variants was found to be kappa 0.752 (95 %CI, 0.733 - 0.771). Normal PD variants were observed in 90.4 % (n = 838/927). Variants of pancreas divisum was identified in 9.6 % (n = 89/927). Abnormalities of the main PD, side branch dilatation, and pancreatic cysts were observed in 2.4 %, 16.6 %, and 27.7 %, respectively, and were not significantly different between pancreas divisum and non-divisum group (P = 0.122; P = 0.152; P = 0.741). There was no association between PD variants and pancreatic exocrine function (P = 0.367). PD variants including pancreas divisum are not associated with morphological signs of chronic pancreatitis or restriction of pancreatic exocrine function. (orig.)

  20. Anatomic variants of the pancreatic duct and their clinical relevance: an MR-guided study in the general population

    Energy Technology Data Exchange (ETDEWEB)

    Buelow, Robin; Thiel, Robert; Thamm, Patrick; Messner, Philip; Hosten, Norbert; Kuehn, Jens-Peter [University Medicine, Ernst Moritz Arndt University Greifswald, Department of Radiology and Neuroradiology, Greifswald (Germany); Simon, Peter; Lerch, Markus M.; Mayerle, Julia [University Medicine, Ernst Moritz Arndt University Greifswald, Division of Gastroenterology and Department of Medicine A, Greifswald (Germany); Voelzke, Henry [University Medicine, Ernst Moritz Arndt University Greifswald, Institute for Community Medicine, Greifswald (Germany)

    2014-12-15

    To investigate the frequency of pancreatic duct (PD) variants and their effect on pancreatic exocrine function in a population-based study using non-invasive secretin-stimulated magnetic resonance cholangiopancreatography (sMRCP). Nine hundred and ninety-five volunteers, 457 women and 538 men, aged 51.9 ± 13.4 years, underwent navigator-triggered, T2-weighted, 3D turbo spin echo MRCP on a 1.5 T system after 1 unit/kg secretin administration. Two readers evaluated images for PD variants. Pancreatic exocrine function and morphological signs of chronic pancreatitis such as abnormalities of the main PD, side branch dilatation, and pancreatic cysts were evaluated and related to PD variants using a Kruskal-Wallis test and post hoc analysis. Of all sMRCP, 93.2 % were of diagnostic quality. Interobserver reliability for detection of PD variants was found to be kappa 0.752 (95 %CI, 0.733 - 0.771). Normal PD variants were observed in 90.4 % (n = 838/927). Variants of pancreas divisum was identified in 9.6 % (n = 89/927). Abnormalities of the main PD, side branch dilatation, and pancreatic cysts were observed in 2.4 %, 16.6 %, and 27.7 %, respectively, and were not significantly different between pancreas divisum and non-divisum group (P = 0.122; P = 0.152; P = 0.741). There was no association between PD variants and pancreatic exocrine function (P = 0.367). PD variants including pancreas divisum are not associated with morphological signs of chronic pancreatitis or restriction of pancreatic exocrine function. (orig.)

  1. Value of MR cisternography using three-dimensional half-fourier single-shot fast spin-echo sequences in the diagnosis of diseases related to cranial nerves VII and VIII

    Energy Technology Data Exchange (ETDEWEB)

    Yamakami, Norio [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1999-05-01

    The purpose of this study was to evaluate the value of MR cisternography using three-dimensional half-Fourier single-shot fast spin-echo sequences in the diagnosis of diseasea related to cranial nerves VII and VIII. With a 0.5-T imager, the most appropriate setting of echo time and section thickness was first assessed in five volunteers. This resulted in echo time of 250 msec and section thickness of 2 mm as the most effective parameters. Second, using echo time of 120 msec and section thickness of 1.5 mm that were available from the beginning of this study, the demonstration of four nerves within the audistory canal was assessed in seven volunteers. In all of the volunteers, the facial, cochlear, and vestibular nerves were determined with demonstration of each of superior and inferior vestibular nerves in four of them. Next, MR cisternography using the same echo time and section thickness was applied in 368 patients with suspicion of acoustic neurinoma and 14 with hemifacial spasm. In 28 of the 368 patients, MR cisternograms depicted an acoustic neurinoma that was confirmed on postcontrast T1-weighted images. Meanwhile, in five of the 14 patients with hemifacial spasm, MR cisternograms revealed a vessel compressing the root exit zone of the affected facial nerve. It is concluded that MR cisternography using three-dimensional half-Fourier single-shot fast spin-echo sequences can be a useful means for demonstrating nerves within the auditory nerve as well as for the screening of acoustic neurionoma. (author)

  2. Value of MR cisternography using three-dimensional half-fourier single-shot fast spin-echo sequences in the diagnosis of diseases related to cranial nerves VII and VIII

    International Nuclear Information System (INIS)

    Yamakami, Norio

    1999-01-01

    The purpose of this study was to evaluate the value of MR cisternography using three-dimensional half-Fourier single-shot fast spin-echo sequences in the diagnosis of diseasea related to cranial nerves VII and VIII. With a 0.5-T imager, the most appropriate setting of echo time and section thickness was first assessed in five volunteers. This resulted in echo time of 250 msec and section thickness of 2 mm as the most effective parameters. Second, using echo time of 120 msec and section thickness of 1.5 mm that were available from the beginning of this study, the demonstration of four nerves within the audistory canal was assessed in seven volunteers. In all of the volunteers, the facial, cochlear, and vestibular nerves were determined with demonstration of each of superior and inferior vestibular nerves in four of them. Next, MR cisternography using the same echo time and section thickness was applied in 368 patients with suspicion of acoustic neurinoma and 14 with hemifacial spasm. In 28 of the 368 patients, MR cisternograms depicted an acoustic neurinoma that was confirmed on postcontrast T1-weighted images. Meanwhile, in five of the 14 patients with hemifacial spasm, MR cisternograms revealed a vessel compressing the root exit zone of the affected facial nerve. It is concluded that MR cisternography using three-dimensional half-Fourier single-shot fast spin-echo sequences can be a useful means for demonstrating nerves within the auditory nerve as well as for the screening of acoustic neurionoma. (author)

  3. Magnetic resonance (MR) in the diagnosis of pancreatic disease

    International Nuclear Information System (INIS)

    Anacker, H.; Rupp, N.; Reiser, M.; Technische Univ. Muenchen

    1984-01-01

    New methods of examination are measured in terms of the efficiency of their predecessors. The introduction of endoscopic retrograde cholangiopancreatography (ERCP) and computerised tomography (CT) constituted a turning point in the diagnosis of pancreatic disease. In this incipient stages as a clinical diagnostic method, the question is raised whether or not there is evidence that magnetic resonance (MR) can supplement, improve upon or replace the customary methods. It must, however, be taken into account that the technical development of MR is still in progress and that clinical experience with MR in the diagnosis of pancreatic disease, as in other areas, is still insufficient. At this point it is only possible to survey the trends. (orig.)

  4. An increased flip angle in late phase Gd-EOB-DTPA MRI shows improved performance in bile duct visualization compared to T2w-MRCP

    Energy Technology Data Exchange (ETDEWEB)

    Stelter, Lars, E-mail: lars.stelter@charite.de [Klinik für Radiologie, Charité – Universitätsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Freyhardt, Patrick, E-mail: patrick.freyhardt@charite.de [Klinik für Radiologie, Charité – Universitätsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Grieser, Christian, E-mail: christian.grieser@charite.de [Klinik für Radiologie, Charité – Universitätsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Walter, Thula, E-mail: thula.walter@charite.de [Klinik für Radiologie, Charité – Universitätsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Geisel, Dominik, E-mail: dominik.geisel@charite.de [Klinik für Radiologie, Charité – Universitätsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Baur, Alexander, E-mail: alexander.baur@charite.de [Klinik für Radiologie, Charité – Universitätsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); and others

    2014-10-15

    Highlights: • EOB-MRC acquired with a flip angle of 35° revealed a better diagnostic performance compared to T2w-MRCP. • EOB-MRC increased the readers’ confidence in identifying anatomic variations of the biliary tree. • As EOB-MRC comprises functional information it is a valuable adjunct to T2w-MRCP. - Abstract: Objectives: To estimate the additional value of an increased flip angle of 35° in late phase Gd-EOB-DTPA-enhanced magnetic resonance cholangiography, as compared to T2w-MRCP. Methods: 40 adult patients underwent Gd-EOB-DTPA enhanced MRI of the liver including a T2-weighted 3D TSE MRCP (T2w-MRCP) as well as a late phase T1-weighted THRIVE sequences applying a flip angle of 35° (fa35). Two experienced observers evaluated the images regarding the delineation of the different biliary regions using a three-point grading system. A five-point scale was applied to determine the readers’ confidence in identifying anatomical variations of the biliary tree. ROI analysis was performed to compare the signal-to-noise (SNR) and contrast-to-noise (CNR) ratios. Results: The quality for visualizing the biliary tree differed between T2w-MRCP and fa35 (p = <0.001). Late phase EOB-MRC was rated as good for delineating the entire biliary system, whereas T2w-MRCP received an overall poor rating. Especially the depiction of the intrahepatic bile ducts was estimated as problematic in T2w-MRCP. T2w-MRCP and fa35 revealed a discordant assessment of anatomical variations in 12.5% of the cases, comprising a generally higher confidence level for fa35 (4.0 ± 1.1 vs. 2.2 ± 1.2, p = <0.001). SNR proofed to be significantly higher in fa35 (p = <0.001), whereas T2w-MRCP revealed a significantly higher CNR (<0.001). Conclusions: Gd-EOB-DTPA enhanced magnetic resonance cholangiography acquired with a flip angle of 35° revealed a better diagnostic performance compared to T2w-MRCP and might be a valuable adjunct in assessing functional bile duct abnormalities.

  5. Readout-Segmented Echo-Planar Imaging in Diffusion-Weighted MR Imaging in Breast Cancer: Comparison with Single-Shot Echo-Planar Imaging in Image Quality

    International Nuclear Information System (INIS)

    Kim, Yun Ju; Kim, Sung Hun; Kang, Bong Joo; Park, Chang Suk; Kim, Hyeon Sook; Son, Yo Han; Porter, David Andrew; Song, Byung Joo

    2014-01-01

    The purpose of this study was to compare the image quality of standard single-shot echo-planar imaging (ss-EPI) and that of readout-segmented EPI (rs-EPI) in patients with breast cancer. Seventy-one patients with 74 breast cancers underwent both ss-EPI and rs-EPI. For qualitative comparison of image quality, three readers independently assessed the two sets of diffusion-weighted (DW) images. To evaluate geometric distortion, a comparison was made between lesion lengths derived from contrast enhanced MR (CE-MR) images and those obtained from the corresponding DW images. For assessment of image parameters, signal-to-noise ratio (SNR), lesion contrast, and contrast-to-noise ratio (CNR) were calculated. The rs-EPI was superior to ss-EPI in most criteria regarding the qualitative image quality. Anatomical structure distinction, delineation of the lesion, ghosting artifact, and overall image quality were significantly better in rs-EPI. Regarding the geometric distortion, lesion length on ss-EPI was significantly different from that of CE-MR, whereas there were no significant differences between CE-MR and rs-EPI. The rs-EPI was superior to ss-EPI in SNR and CNR. Readout-segmented EPI is superior to ss-EPI in the aspect of image quality in DW MR imaging of the breast

  6. Comparison of ultrasound evaluation of patients of obstructive jaundice with endoscopic retrograde cholangio-pancreatography findings

    International Nuclear Information System (INIS)

    Farrukh, S.Z.U.I.; Siddiqui, A.R.; Haqqi, S.A.; Muhammad, A.J.

    2017-01-01

    Ultrasonography has proven to be quite effective in differentiating hepatocellular from obstructive cause of jaundice in various studies. This study was conducted with the aim to determine the efficacy of ultrasonography and Endoscopic Retrograde Cholangio-Pancreatography (ERCP) in the diagnosis of obstructive reason of jaundice. Methods: In this descriptive case series, 200 patients with >15 years age of either gender with cholestatic liver enzymes were included, i.e., those patients who had an ultrasound prior to ERCP at the department of gastroenterology of Patel Hospital, Karachi. Patients known to have liver disease with cholestatic jaundice had imaging other than ultrasound were excluded. The results of ultrasonography and ERCPs were compared in particularly looking for the cause of obstruction. Results: Out of total 200 patients, mean age was 41.22+-12.46 years with 107 (53.5 percent) females. Ability of ultrasound in correctly diagnosing obstructive reason for stone CBD was found to be 72.5 percent, dilated CBD without reason 41.7 percent, proximal obstruction, 63.15 percent, distal CBD obstruction 60 percent, and sludge 66.7 percent. Overall ability of ultrasound in correctly diagnosing the cause of obstruction was 64.17 percent. Conclusion: Ultrasound is recommended as the initial examination, which provides a guide to choose patients for either a more advanced non-invasive imaging like MRCP or to an invasive procedure like ERCP. (author)

  7. MRI of oriental cholangiohepatitis

    Energy Technology Data Exchange (ETDEWEB)

    Wani, N.A., E-mail: ahmad77chinar@gmail.co [Department of Radiodiagnosis and Imaging, Sher-I-Kashmir Institute of Medical Sciences (SKIMS), Srinagar (India); Robbani, I.; Kosar, T. [Department of Radiodiagnosis and Imaging, Sher-I-Kashmir Institute of Medical Sciences (SKIMS), Srinagar (India)

    2011-02-15

    Oriental cholangiohepatitis (OCH) also called recurrent pyogenic cholangitis is characterized by intrahepatic duct calculi, strictures, and recurrent infections. In turn cholangitis can result in multiple hepatic abscesses, further biliary strictures, and in severe cases, progressive hepatic parenchymal destruction, cirrhosis, and portal hypertension. Magnetic resonance cholangiopancreatography (MRCP) and conventional T1-weighted (T1 W) and T2-weighted (T2 W) magnetic resonance imaging (MRI) findings have been described in patients with OCH. MRCP findings include duct dilation, strictures, and calculi. MRCP can help to localize the diseased ducts and determine the severity of involvement. T1 and T2 W sequences reveal the parenchymal changes of atrophy, abscess formation, and portal hypertension in addition to calculi. Post-treatment changes are also well depicted using MRI. Comprehensive, non-invasive assessment is achieved by using conventional MRI and MRCP in OCH providing a roadmap for endoscopic or surgical management.

  8. Normal anatomy of the fetus at MR imaging.

    Science.gov (United States)

    Amin, R S; Nikolaidis, P; Kawashima, A; Kramer, L A; Ernst, R D

    1999-10-01

    Owing to recent advances in magnetic resonance (MR) imaging, the role of obstetric MR imaging has increased in cases in which the results of ultrasonography are equivocal. Fast MR imaging sequences, such as T2-weighted fast spin-echo (SE), half-Fourier single-shot fast SE, 0.5-signal-acquired single-shot fast SE, and echo-planar imaging, have virtually eliminated the need for fetal premedication, with a concomitant improvement in image resolution and diminished blurring. Artifacts related to maternal respiratory motion and fetal motion no longer limit the anatomic detail that can be demonstrated with MR imaging. With such advances in obstetric MR imaging, knowledge of normal fetal anatomy at MR imaging is essential to detect disease in utero. MR imaging can demonstrate fetal anatomy in detail, especially the brain, thorax, abdomen, pelvis, and vasculature. Major developmental structures of the fetus, particularly the cranial nervous system, naso- and oropharynx, lungs, and major abdominal viscera, can be adequately evaluated with targeted fast MR imaging as early as the beginning of the second trimester. However, MR imaging of the heart remains limited. Fetal MR imaging during the first trimester remains controversial secondary to biosafety issues and is limited due to diminutive fetal size.

  9. Endoscopic retrograde cholangiopancreatography and endoscopic ...

    African Journals Online (AJOL)

    An approach to suspected gallstone pancreatitis'based on endoscopic retrograde cholangiopancreatography (ERCP) and endoscopic sphincterotomy (ES) was adopted in 1976 and was followed in 29 patients. ERCp became the routine method of early biliary tract assessment when gallstone pancreatitis was suspected on ...

  10. Optimal Timing for Laparoscopic Cholecystectomy After Endoscopic Retrograde Cholangiopancreatography: A Systematic Review.

    Science.gov (United States)

    Friis, C; Rothman, J P; Burcharth, J; Rosenberg, J

    2018-06-01

    Endoscopic retrograde cholangiopancreatography followed by laparoscopic cholecystectomy is often used as definitive treatment for common bile duct stones. The aim of this study was to investigate the optimal time interval between endoscopic retrograde cholangiopancreatography and laparoscopic cholecystectomy. PubMed and Embase were searched for studies comparing different time delays between endoscopic retrograde cholangiopancreatography and laparoscopic cholecystectomy. Observational studies and randomized controlled trials were included. Primary outcome was conversion rate from laparoscopic to open cholecystectomy and secondary outcomes were complications, mortality, operating time, and length of stay. A total of 14 studies with a total of 1930 patients were included. The pooled estimate revealed an increase from a 4.2% conversion rate when laparoscopic cholecystectomy was performed within 24 h of endoscopic retrograde cholangiopancreatography to 7.6% for 24-72 h delay to 12.3% when performed within 2 weeks, to 12.3% for 2-6 weeks, and to a 14% conversion rate when operation was delayed more than 6 weeks. According to this systematic review, it is preferable to perform cholecystectomy within 24 h of endoscopic retrograde cholangiopancreatography to reduce conversion rate. Early laparoscopic cholecystectomy does not increase mortality, perioperative complications, or length of stay and on the contrary it reduces the risk of reoccurrence and progression of disease in the delay between endoscopic retrograde cholangiopancreatography and laparoscopic cholecystectomy.

  11. A prospective, comparative study of magnetic resonance cholangipancreatography and direct cholangiography in the diagnosis of biliary diseases

    International Nuclear Information System (INIS)

    Fernandez, E.; Falco, J.; Martin, J.; Brullet, E.; Campo, R.; Espinos, J.; Darnell, A.

    2001-01-01

    To assess the sensitivity and specificity of magnetic resonance cholangiopancreatography (MRCP) as a noninvasive diagnostic technique, comparing it with endoscopic retrograde cholangiopancreatography (ERCP) and percutaneous transhepatic cholangiography (PTHC) in the diagnosis of biliary disease, focusing particularly on patients with choledocholithiasis. Between June 1997 and february 1998, 109 patients referred by the Corporacio Sanitaria del Parc Tauli and the Hospital Mutua de terrasa in Barcelona, Spain were evaluated. MRCP and ERCP or PTHC were performed in every case, always in that order and separated by a maximum of 7 days. Twenty-four patients were excluded from the study for different reasons, leaving a series of 85 patients. All the studies were performed with a 1-Tesla Siemens Magneton Impact Expert using half-fourier single-short turbo spin-echo (HASTE) and rapid acquisition with relaxation enhancement (RARE) methods in several coronal and axial planes. The MRCP readings were carried out by consensus by two radiologists who are experts in the assessment of diseases of the digestive tract. In this series of 85 patients; MCRP showed a sensitivity of 98.4%, a specificity of 94.7%, a positive predictive value of 98.4% and a negative predictive value of 94.7% for the detection of biliary diseases. For the detection choledocholithiasis, these values were 100%, 89.5%, 88% and 100%, respectively. MRCP is extremely reliable in the diagnosis of biliary diseases, especially in cases of choledocholithiasis. Its high negative predictive value obviates the need for other invasive diagnostic tests. (Author) 30 refs

  12. A prospective, comparative study of magnetic resonance cholangipancreatography and direct cholangiography in the diagnosis of biliary diseases; Estudio propsective comparativo en el diagnostico de la patologia biliar. Colangiopancreatografia por resonancia magnetica frente a colangiografia directa

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, E.; Falco, J.; Martin, J.; Brullet, E.; Campo, R.; Espinos, J.; Darnell, A.

    2001-07-01

    To assess the sensitivity and specificity of magnetic resonance cholangiopancreatography (MRCP) as a noninvasive diagnostic technique, comparing it with endoscopic retrograde cholangiopancreatography (ERCP) and percutaneous transhepatic cholangiography (PTHC) in the diagnosis of biliary disease, focusing particularly on patients with choledocholithiasis. Between June 1997 and february 1998, 109 patients referred by the Corporacio Sanitaria del Parc Tauli and the Hospital Mutua de terrasa in Barcelona, Spain were evaluated. MRCP and ERCP or PTHC were performed in every case, always in that order and separated by a maximum of 7 days. Twenty-four patients were excluded from the study for different reasons, leaving a series of 85 patients. All the studies were performed with a 1-Tesla Siemens Magneton Impact Expert using half-fourier single-short turbo spin-echo (HASTE) and rapid acquisition with relaxation enhancement (RARE) methods in several coronal and axial planes. The MRCP readings were carried out by consensus by two radiologists who are experts in the assessment of diseases of the digestive tract. In this series of 85 patients; MCRP showed a sensitivity of 98.4%, a specificity of 94.7%, a positive predictive value of 98.4% and a negative predictive value of 94.7% for the detection of biliary diseases. For the detection choledocholithiasis, these values were 100%, 89.5%, 88% and 100%, respectively. MRCP is extremely reliable in the diagnosis of biliary diseases, especially in cases of choledocholithiasis. Its high negative predictive value obviates the need for other invasive diagnostic tests. (Author) 30 refs.

  13. Gadolinium-enhanced excretory MR urography: comparison with MR urography using HASTE technique

    International Nuclear Information System (INIS)

    Jin, Gong Yong; Lee, Jeong Min; Han, Young Min; Cheong, Gyung Ho; Oh, Hee Sul; Kim, Chong Soo; Park, Sung Kwang; Kim, Young Gon

    2000-01-01

    To compare the feasibility of gadolinium-enhanced excretory MR urography (GEMRU) and conventional MR urography using the half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence in patients with hydronephrosis or non-visualized kidney. Fifteen patients with hydronephrosis or non-visualized kidney, as demonstrated by ultrasonography or intravenous urography, were enrolled in this study. Nine were men and six were women, and their age ranged from 18 to 77 (mean, 60.6) years. For all MR examinations, a 1.5T MR unit was employed. For breath-hold MR urography, the HASTE technique (MRU) was used, and reconstruction involved the use of a maximum intensity-projection (MIP) algorithm. For gadolinium-enhanced excretory MR urography, the fast low angle shot (FLASH) 3-D method was used and images were obtained at 5, 10, 20, and 30 minutes, and reconstruction again involved the use of MIP algorithm. In some cases, additional GEMRU was obtained 24 hour after contrast material injection, and an MIP algorithm was used for reconstruction. MRU and GEMRU were independently interpreted by two radiologists who for quantitative analysis compared SNR with CNR, and at each anatomic level qualitatively analyzed morphologic accuracy and diagnostic value of the lesions. In quantitative analysis, SNR and CNR differences between the two sequences at the renal pelvis and the level of the ureter were not significant (p greater than 0.05). In qualitative analysis, GEMRU was superior to MRU for the assessment of evaluated ureter at each level (p less than 0.05), anatomic anomaly and intrinsic tumor. Ureteral stones, however, were more easily diagnosed with MRU. For assessment of the ureter GEMRU is superior to MRU and has the advantage of evaluating renal function. We believe that for evaluation of the urinary tract, especially the distal ureter, GEMRU may be a valuable adjunct to routine MR urography. (author)

  14. Postprandial changes in secretory flow of pancreatic juice in the main pancreatic duct: evaluation with cine-dynamic MRCP with a spatially selective inversion-recovery (IR) pulse.

    Science.gov (United States)

    Yasokawa, Kazuya; Ito, Katsuyoshi; Tamada, Tsutomu; Yamamoto, Akira; Hayashida, Minoru; Torigoe, Teruyuki; Tanimoto, Daigo; Higaki, Atsushi; Noda, Yasufumi; Kido, Ayumu

    2016-12-01

    To evaluate the influence of oral ingestion on the secretory flow dynamics of physiological pancreatic juice within the main pancreatic duct in healthy subjects by using cine-dynamic MRCP with spatially-selective inversion-recovery (IR) pulse non-invasively. Thirty-eight healthy subjects were investigated. MRCP with spatially-selective IR pulse was repeated every 15 s for 5 min to acquire a total of 20 images (cine-dynamic MRCP). A set of 20 MRCP images was repeatedly obtained before and after liquid oral ingestion every 7 min (including 2-min interval) for 40 min (a total of seven sets). Secretion grade of pancreatic juice on cine-dynamic MRCP was compared before and after oral ingestion using the nonparametric Wilcoxon signed-rank test. Median secretion grades of pancreatic juice at 5 min (score = 2.15), 12 min (score = 1.95) and 19 min (score = 2.05) after ingestion were significantly higher than that before ingestion (score = 1.40) (P = 0.004, P = 0.032, P = 0.045, respectively). Secretion grade of pancreatic juice showed a maximum peak of 2.15 at 5 min after ingestion. Thereafter, the secretion grade of pancreatic juice tended to gradually decline. Non-invasive cine-dynamic MRCP using spatially-selective IR pulse showed potential for evaluating postprandial changes in the secretory flow dynamics of pancreatic juice as a physiological reaction. • Secretion grade of pancreatic juice at cine-dynamic MRCP after ingestion was evaluated. • Secretion grade was significantly increased within 19 min after liquid meal ingestion. • Secretion grade showed maximum peak of 2.15 at 5 min after ingestion. • Postprandial changes in pancreatic juice flow can be assessed by cine-dynamic MRCP.

  15. Single-shot echo-planar MR sequences in the diagnosis of intracranial infectious diseases

    International Nuclear Information System (INIS)

    Tsuchiya, Kazuhiro; Katase, Shichiro; Yoshino, Ayako; Yamakami, Norio; Hachiya, Junichi

    1998-01-01

    The purpose of this study was to present our preliminary experience in the application of echo-planar-imaging (EPI) MR sequences for the diagnosis of intracranial infectious diseases and to assess the value of these sequences. We reviewed single-shot EPI MR images obtained at 1.5 T in 17 patients and compared these images with conventional or fast spin-echo (SE) or fluid attenuated inversion-recovery (FLAIR) images. The clinical diagnoses for the 17 patients were meningitis (2 patients), encephalitis or meningoencephalitis (7 patients), brain abscess (5 patients), epidural empyema (2 patients) and Creutzfeldt-Jakob disease (1 patient). We obtained EPI-T 2 -weighted (T 2 W) images in 8 patients, EPI-FLAIR images in 13 patients and EPI-diffusion-weighted (DW) images in 14 patients. Among the 8 patients for whom EPI-T 2 W imaging was performed, EPI-T 2 W imaging yielded superior results compared with SE-T 2 W imaging in 3 patients as a consequence of patient motion and equal results compared with SE-T 2 W imaging in 5 patients. Among the 13 patients for whom EPI-FLAIR imaging was performed, the EPI-FLAIR images were superior to conventional FLAIR images in 3 unstable patients. In the remaining 10 patients for whom EPI-FLAIR imaging was performed, EPI-FLAIR images were equivalent or inferior to conventional FLAIR images. In 6 patients with encephalitis or meningoencephalitis, the encephalitic lesions showed hyperintensity in EPI-DW images to a greater extent than in images obtained with the other techniques. In 3 patients, EPI-DW images also demonstrated hyperintensity for the contents of abscesses or areas of empyema that was not seen with the other imaging techniques. The value of EPI-T 2 W and EPI-FLAIR imaging is limited in uncooperative patients. EPI-DW imaging was found to be of value for the evaluation of several intracranial infectious diseases. (author)

  16. Single-shot echo-planar MR sequences in the diagnosis of intracranial infectious diseases

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, Kazuhiro; Katase, Shichiro; Yoshino, Ayako; Yamakami, Norio; Hachiya, Junichi [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1998-06-01

    The purpose of this study was to present our preliminary experience in the application of echo-planar-imaging (EPI) MR sequences for the diagnosis of intracranial infectious diseases and to assess the value of these sequences. We reviewed single-shot EPI MR images obtained at 1.5 T in 17 patients and compared these images with conventional or fast spin-echo (SE) or fluid attenuated inversion-recovery (FLAIR) images. The clinical diagnoses for the 17 patients were meningitis (2 patients), encephalitis or meningoencephalitis (7 patients), brain abscess (5 patients), epidural empyema (2 patients) and Creutzfeldt-Jakob disease (1 patient). We obtained EPI-T{sub 2}-weighted (T{sub 2}W) images in 8 patients, EPI-FLAIR images in 13 patients and EPI-diffusion-weighted (DW) images in 14 patients. Among the 8 patients for whom EPI-T{sub 2}W imaging was performed, EPI-T{sub 2}W imaging yielded superior results compared with SE-T{sub 2}W imaging in 3 patients as a consequence of patient motion and equal results compared with SE-T{sub 2}W imaging in 5 patients. Among the 13 patients for whom EPI-FLAIR imaging was performed, the EPI-FLAIR images were superior to conventional FLAIR images in 3 unstable patients. In the remaining 10 patients for whom EPI-FLAIR imaging was performed, EPI-FLAIR images were equivalent or inferior to conventional FLAIR images. In 6 patients with encephalitis or meningoencephalitis, the encephalitic lesions showed hyperintensity in EPI-DW images to a greater extent than in images obtained with the other techniques. In 3 patients, EPI-DW images also demonstrated hyperintensity for the contents of abscesses or areas of empyema that was not seen with the other imaging techniques. The value of EPI-T{sub 2}W and EPI-FLAIR imaging is limited in uncooperative patients. EPI-DW imaging was found to be of value for the evaluation of several intracranial infectious diseases. (author)

  17. Magnetic Resonance Cholangiopancreatographv: A Meta-Analysis of Test Performance in Suspected Biliary Disease

    International Nuclear Information System (INIS)

    Romagnuolo J; Bardou M; Rahme, E and others

    2004-01-01

    Magnetic resonance cholangiopancreatography (MRCP) is one of many newer noninvasive tests that can image the biliary tree. To precisely estimate the overall sensitivity and specificity of MRCP in suspected biliary obstruction and to evaluate clinically important subgroups. MEDLINE search (January 1987 to March 2003) for studies in English or French, bibliographies, and subject matter experts. Studies were included if they allowed construction of 2x2 contingency tables of MRCP compared with a reasonable gold standard for at least 1 of the following: the presence, level, or cause of biliary obstruction. Two independent observers graded study quality, which included consecutive enrollment, blinding, use of a single (versus composite) gold standard, and nonselective use of the gold standard. Logistic regression was used to examine the influence of publication year, quality score, proportion of patients having a direct gold standard, and clinical context on diagnostic performance. Of 498 studies identified, 67 were included (4711 patients). Mixed-effect models were used to estimate the sensitivity and specificity, and quantitative receiver-operating characteristic analysis was performed. Magnetic resonance cholangiopancreatography had a high overall pooled sensitivity (95% (+/-1.96 SD: spread of SD, 75% to 99%) and specificity (97% (spread of SD, 86% to 99 %)) The procedure was less sensitive for stones (92%; odds ratio, 0.51 (CI, 0.35 to 0.75) and malignant conditions (88%; odds ratio, 0.28 (CI, 0.18 to 0.44f) than for the presence of obstruction, In addition, diagnostic performance was higher in studies that were larger, did not use consecutive enrollment, and did not use gold standard assessment for some patients. Magnetic resonance cholangiopancreatography is a noninvasive imaging test with excellent overall sensitivity and specificity for demonstrating the level and presence of biliary obstruction; however, it seems less sensitive for detecting stones or

  18. Postprandial changes in secretory flow of pancreatic juice in the main pancreatic duct: evaluation with cine-dynamic MRCP with a spatially selective inversion-recovery (IR) pulse

    International Nuclear Information System (INIS)

    Yasokawa, Kazuya; Ito, Katsuyoshi; Tamada, Tsutomu; Yamamoto, Akira; Hayashida, Minoru; Torigoe, Teruyuki; Tanimoto, Daigo; Higaki, Atsushi; Noda, Yasufumi; Kido, Ayumu

    2016-01-01

    To evaluate the influence of oral ingestion on the secretory flow dynamics of physiological pancreatic juice within the main pancreatic duct in healthy subjects by using cine-dynamic MRCP with spatially-selective inversion-recovery (IR) pulse non-invasively. Thirty-eight healthy subjects were investigated. MRCP with spatially-selective IR pulse was repeated every 15 s for 5 min to acquire a total of 20 images (cine-dynamic MRCP). A set of 20 MRCP images was repeatedly obtained before and after liquid oral ingestion every 7 min (including 2-min interval) for 40 min (a total of seven sets). Secretion grade of pancreatic juice on cine-dynamic MRCP was compared before and after oral ingestion using the nonparametric Wilcoxon signed-rank test. Median secretion grades of pancreatic juice at 5 min (score = 2.15), 12 min (score = 1.95) and 19 min (score = 2.05) after ingestion were significantly higher than that before ingestion (score = 1.40) (P = 0.004, P = 0.032, P = 0.045, respectively). Secretion grade of pancreatic juice showed a maximum peak of 2.15 at 5 min after ingestion. Thereafter, the secretion grade of pancreatic juice tended to gradually decline. Non-invasive cine-dynamic MRCP using spatially-selective IR pulse showed potential for evaluating postprandial changes in the secretory flow dynamics of pancreatic juice as a physiological reaction. (orig.)

  19. Postprandial changes in secretory flow of pancreatic juice in the main pancreatic duct: evaluation with cine-dynamic MRCP with a spatially selective inversion-recovery (IR) pulse

    Energy Technology Data Exchange (ETDEWEB)

    Yasokawa, Kazuya; Ito, Katsuyoshi; Tamada, Tsutomu; Yamamoto, Akira; Hayashida, Minoru; Torigoe, Teruyuki; Tanimoto, Daigo; Higaki, Atsushi; Noda, Yasufumi; Kido, Ayumu [Kawasaki Medical School, Department of Diagnostic Radiology, Kurashiki, Okayama (Japan)

    2016-12-15

    To evaluate the influence of oral ingestion on the secretory flow dynamics of physiological pancreatic juice within the main pancreatic duct in healthy subjects by using cine-dynamic MRCP with spatially-selective inversion-recovery (IR) pulse non-invasively. Thirty-eight healthy subjects were investigated. MRCP with spatially-selective IR pulse was repeated every 15 s for 5 min to acquire a total of 20 images (cine-dynamic MRCP). A set of 20 MRCP images was repeatedly obtained before and after liquid oral ingestion every 7 min (including 2-min interval) for 40 min (a total of seven sets). Secretion grade of pancreatic juice on cine-dynamic MRCP was compared before and after oral ingestion using the nonparametric Wilcoxon signed-rank test. Median secretion grades of pancreatic juice at 5 min (score = 2.15), 12 min (score = 1.95) and 19 min (score = 2.05) after ingestion were significantly higher than that before ingestion (score = 1.40) (P = 0.004, P = 0.032, P = 0.045, respectively). Secretion grade of pancreatic juice showed a maximum peak of 2.15 at 5 min after ingestion. Thereafter, the secretion grade of pancreatic juice tended to gradually decline. Non-invasive cine-dynamic MRCP using spatially-selective IR pulse showed potential for evaluating postprandial changes in the secretory flow dynamics of pancreatic juice as a physiological reaction. (orig.)

  20. Does Courvoisier's sign stand the test of time?

    LENUS (Irish Health Repository)

    Murphy, K

    2012-11-01

    To investigate the validity of Courvoisier\\'s sign, in the age of cross-sectional imaging and image analysis software by objectively measuring gallbladder volumes at magnetic resonance cholangiopancreatography (MRCP) in patients with and without biliary obstruction and to assess whether gallbladder volume is more significantly increased in patients with gallstone-related rather than non-gallstone-related biliary obstruction.

  1. Comparison of single-shot fast spin-echo sequence and T2-weighted fast spin-echo sequence in MR imaging of the brain

    International Nuclear Information System (INIS)

    Cha, Sung Ho; Seo, Jeong Jin; Jeong, Gwang Woo; Kim, Jae Kyu; Kim, Yun Hyeon; Jeong, Yong Yeon; Kang, Heoung Keun; Oh, Hee Yeon; Yoon, Jong Hoon

    1998-01-01

    The purpose of this study was to evaluate the usefulness of the single-shot fast spinecho (SS-FSE) sequence in comparison with the T2-weighted fast spin-echo (T2-FSE) sequence in brain MR imaging. In 41 patients aged 15-75 years with intracranial lesion, both SS-FSE and T2-FES images were obtained using a 1.5-T MR system. Lesions included cerebral ischemia or infarcts (n=3D23), tumors (n=3D10), hemorrhages (n=3D3), inflammatory diseases (n=3D2), arachnoid cysts(n=3D2), and vascular disease (n=3D1), and the MR images were retrospectively evaluated. To calculate contrast-to-noise ratio (CNR), percentage contrast, and signal-to-noise ratio (SNR)-and thus make a quantitative comparison-the mean signal intensities of lesions, normal brain tissue, and noise out-side the patient were measured. For qualitative comparison, the visibility, margin, and extent of the lesions were rated using a five-grade system, and the degree of MR artifacts was also evaluated. Wilcoxon's signed ranks test was used for statistical analysis. The mean CNR of lesions was significantly higher on SS-FSE (31.3) than on T2-FSE images (27.5) (p=3D0.0131). Mean percentage contrast was also higher on SS-FSE (159.0) than on T2-FSE images (108.5) (p=3D0.0222), but mean SNR was higher on T2-FSE (80.3) than on SS-FSE images (53.5) (p=3D0.0000). No significant differences in lesion visibility were observed between the two imaging sequences, though margin and extent of the lesion were worse on SS-FSE images. For MR artifacts, no significant differences were demonstrated. For the evaluation of most intracranial lesions, MR imaging using the SS-FSE sequence appears to be slightly inferior to the T2-FSE sequence, but may be useful where patients are ill or uncooperative, or where children require sedation.=20

  2. Implementing statistical equating for MRCP(UK) Parts 1 and 2.

    Science.gov (United States)

    McManus, I C; Chis, Liliana; Fox, Ray; Waller, Derek; Tang, Peter

    2014-09-26

    The MRCP(UK) exam, in 2008 and 2010, changed the standard-setting of its Part 1 and Part 2 examinations from a hybrid Angoff/Hofstee method to statistical equating using Item Response Theory, the reference group being UK graduates. The present paper considers the implementation of the change, the question of whether the pass rate increased amongst non-UK candidates, any possible role of Differential Item Functioning (DIF), and changes in examination predictive validity after the change. Analysis of data of MRCP(UK) Part 1 exam from 2003 to 2013 and Part 2 exam from 2005 to 2013. Inspection suggested that Part 1 pass rates were stable after the introduction of statistical equating, but showed greater annual variation probably due to stronger candidates taking the examination earlier. Pass rates seemed to have increased in non-UK graduates after equating was introduced, but was not associated with any changes in DIF after statistical equating. Statistical modelling of the pass rates for non-UK graduates found that pass rates, in both Part 1 and Part 2, were increasing year on year, with the changes probably beginning before the introduction of equating. The predictive validity of Part 1 for Part 2 was higher with statistical equating than with the previous hybrid Angoff/Hofstee method, confirming the utility of IRT-based statistical equating. Statistical equating was successfully introduced into the MRCP(UK) Part 1 and Part 2 written examinations, resulting in higher predictive validity than the previous Angoff/Hofstee standard setting. Concerns about an artefactual increase in pass rates for non-UK candidates after equating were shown not to be well-founded. Most likely the changes resulted from a genuine increase in candidate ability, albeit for reasons which remain unclear, coupled with a cognitive illusion giving the impression of a step-change immediately after equating began. Statistical equating provides a robust standard-setting method, with a better

  3. MR myelography of sacral meningeal cysts

    International Nuclear Information System (INIS)

    Tsuchiya, K.; Katase, S.; Hachiya, J.

    1999-01-01

    Purpose: To describe the findings of sacral meningeal cysts (SMCs) on MR myelography and assess its value for the diagnosis of SMCs. Material and Methods: We evaluated the MR images and MR myelograms obtained from 10 patients with SMC. MR myelograms were obtained using a 2D or 3D single-shot fast spin-echo sequence. In 5 patients, X-ray myelograms and postmyelographic CT images were compared with the MR myelograms. Results: A total of 33 SMCs were diagnosed within the spinal canal and/or sacral foramen. MR myelograms clearly revealed each cyst as a well-defined mass showing hyperintensity (10 cysts) or isointensity (23 cysts) compared to cerebrospinal fluid. MR myelograms demonstrated SMCs better than X-ray myelograms and postmyelographic CT images in 3 of the 5 patients. Conclusion: MR myelography can be an adjunct to conventional imaging techniques when surgical treatment is indicated, because it can precisely delineate the extent of SMCs. (orig.)

  4. Cine MR imaging in valvular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Tsunehiko; Yamada, Naoaki; Itoh, Akira; Miyatake, Kunio

    1989-01-01

    Cine MR Imaging was carried out using FLASH (fast low angle shot) which employes TE of 16 msec and TR of 30/similar to/40 msec. Regurgitant jet was visible as discrete area of low signal intensity extending from the incompetent valve into the respective cardiac chamber. In 20 patients with mitral regurgitation, the correlation of the length and area of mitral jet by cine MR and color doppler mapping was 0.74 and 0.71, respectively. Cine MR imaging is a promising modality for detection and quantification of valvular heart disease.

  5. Ansa Pancreatica: A Case Report of a Type of Ductal Variation in a Patient with Idiopathic Acute Recurrent Pancreatitis

    International Nuclear Information System (INIS)

    Kim, Hye Mi; Park, Jung Yup; Kim, Myeong Jin

    2010-01-01

    Ansa pancreatica is a rare type of pancreatic ductal variation. Recently, ansa pancreatic has been considered as a predisposing factor in patients with idiopathic acute pancreatitis. To the best of our knowledge, no previously published report in Korea has described ansa pancreatica. We report a case of acute recurrent pancreatitis with ansa pancreatica, which was revealed on magnetic resonance cholangiopancreatography (MRCP)

  6. MR imaging of the gastrointestinal tract with half-fourier single-shot fast spin echo (SSFSE)

    International Nuclear Information System (INIS)

    Boku, Houjun; Takehara, Yasuo; Isoda, Haruo; Isogai, Satoshi; Kaneko, Masao

    1999-01-01

    Our objective was to implement a non-invasive magnetic resonance imaging (MRI) technique combined with concentrated milk ingestion for depicting the gastrointestinal (GI) tract and detecting gastrointestinal motility and transit. The half-Fourier SSFSE (single-shot fast spin echo) sequence was optimized on the basis of a phantom study. In order to determine the feasibility of milk ingestion as a substitute for contrast medium, ten human volunteers were examined with SSFSE after two types of liquid ingestion (i.e., milk and water). The snapshot images provided subsecond data acquisition for each coronal plane, allowing visualization of peristalsis in the gastrointestinal tract in an almost real-time fashion, without motion-related image degradation, as would normally be seen using conventional MRI. There was no significant difference between concentrated milk and water in terms of depiction of the upper gastrointestinal tract; however, 10 min and 30 min after ingestion, concentrated milk showed better delineation of the intestine than that observed after water ingestion (p<0.01). MR gastrointestinal imaging is a non-invasive method that allows gastrointestinal depiction as well as analysis of motility and passage. Especially with concentrated milk ingestion, the distal intestines were well depicted with adequate contrast filling and distention. (author)

  7. Evaluation of late stage iatrogenic extrahepatic bile duct stricture by using magnetic resonance cholangiopancreagraphy

    International Nuclear Information System (INIS)

    Sun Changjin; Zhou Xiangping; Liu Rongbo; Song Bin; Yan Zhihan; Chen Xian; Wang Wentao; Xiong Yan; Xu Minsheng; Gu Jianping

    2003-01-01

    Objective: To assess the role of magnetic resonance cholangiopancreagraphy (MRCP) in the preoperative evaluation of late stage iatrogenic extrahepatic bile duct stricture. Methods: Eighteen cases, which were diagnosed as late stage iatrogenic extrahepatic bile duct strictures only by MRCP and proved by surgery and pathology, were classified according to Bismuth classification and the surgical operation strategy was planed on the basis of MR cholangiopancreagraphic findings before surgery. The results were compared with surgery. Results: Diagnostic MR Cholangiopancreagrams were acquired in 18 patients. Among all 18 patients, the level of stricture was classified as Bismuth I in 3 patients, Bismuth II in 7 patients, Bismuth III in 3 patients, and Bismuth IV in 3 patients. A Bismuth II stricture was incorrectly classified as a Bismuth III lesion. On the basis of MR cholangiopancreagraphic findings, a surgical operation strategy can be planed. The therapeutic plan anticipated with MRCP matched the actually used procedure in 16 of 18 patients. conclusion: MRCP plays an important role in the evaluation of late stage iatrogenic extrahepatic bile duct stricture

  8. Endoscopic retrograde cholangiopancreatography causes reduced myocardial blood flow

    DEFF Research Database (Denmark)

    Christensen, M; Hendel, H W; Rasmussen, V

    2002-01-01

    BACKGROUND AND STUDY AIMS: Previous studies have shown that up to 50% of healthy patients may develop ST-segment changes during upper gastrointestinal endoscopy. The aim of the study was to evaluate myocardial blood flow in patients during endoscopic retrograde cholangiopancreatography (ERCP...

  9. Massive pleural effusion in a young woman

    OpenAIRE

    Ghiringhelli, Paolo; Cattaneo, Roberto; Tiso, Angelo; Cesaro, Claudia

    2012-01-01

    Pleural effusion is a clinical manifestation shared by several underlying pathologies. The differential diagnosis is based on the clinical history, the physical examination, the analysis of the pleural fluid, and the laboratory data (mainly blood tests). There are cases, such as the patient described, where TC is not enough, and unusual imaging techniques are required for the study of pleural effusion, i.e. magnetic resonance cholangiography, cholangiopancreatography (MRCP) and endoscopic ret...

  10. Clinical evaluation of single-shot and readout-segmented diffusion-weighted imaging in stroke patients at 3 T

    International Nuclear Information System (INIS)

    Morelli, John; Porter, David; Ai, Fei

    2013-01-01

    Background: Diffusion-weighted imaging (DWI) magnetic resonance imaging (MRI) is most commonly performed utilizing a single-shot echo-planar imaging technique (ss-EPI). Susceptibility artifact and image blur are severe when this sequence is utilized at 3 T. Purpose: To evaluate a readout-segmented approach to DWI MR in comparison with single-shot echo planar imaging for brain MRI. Material and Methods: Eleven healthy volunteers and 14 patients with acute and early subacute infarctions underwent DWI MR examinations at 1.5 and 3T with ss-EPI and readout-segmented echo-planar (rs-EPI) DWI at equal nominal spatial resolutions. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) calculations were made, and two blinded readers ranked the scans in terms of high signal intensity bulk susceptibility artifact, spatial distortions, image blur, overall preference, and motion artifact. Results: SNR and CNR were greatest with rs-EPI (8.1 ± 0.2 SNR vs. 6.0 ± 0.2; P -4 at 3T). Spatial distortions were greater with single-shot (0.23 ± 0.03 at 3T; P <0.001) than with rs-EPI (0.12 ± 0.02 at 3T). Combined with blur and artifact reduction, this resulted in a qualitative preference for the readout-segmented scans overall. Conclusion: Substantial image quality improvements are possible with readout-segmented vs. single-shot EPI - the current clinical standard for DWI - regardless of field strength (1.5 or 3 T). This results in improved image quality secondary to greater real spatial resolution and reduced artifacts from susceptibility in MR imaging of the brain

  11. Endoscopic Sphincterotomy Using the Rendezvous Technique for Choledocholithiasis during Laparoscopic Cholecystectomy: A Case Report.

    Science.gov (United States)

    Tanaka, Takayuki; Haraguchi, Masashi; Tokai, Hirotaka; Ito, Shinichiro; Kitajima, Masachika; Ohno, Tsuyoshi; Onizuka, Shinya; Inoue, Keiji; Motoyoshi, Yasuhide; Kuroki, Tamotsu; Kanemastu, Takashi; Eguchi, Susumu

    2014-05-01

    A 50-year-old male was examined at another hospital for fever, general fatigue and slight abdominal pain. He was treated with antibiotics and observed. However, his symptoms did not lessen, and laboratory tests revealed liver dysfunction, jaundice and an increased inflammatory response. He was then admitted to our hospital and underwent an abdominal computed tomography scan and magnetic resonance cholangiopancreatography (MRCP), which revealed common bile duct (CBD) stones. He was diagnosed with mild acute cholangitis. As the same time, he was admitted to our hospital and an emergency endoscopic retrograde cholangiopancreatography was performed. Vater papilla opening in the third portion of the duodenum and presence of a peripapillary duodenal diverticulum made it difficult to perform cannulation of the CBD. In addition, MRCP revealed that the CBD was extremely narrow (diameter 5 mm). We therefore performed laparoscopic cholecystectomy and endoscopic sphincterotomy using the rendezvous technique for choledocholithiasis simultaneously rather than laparoscopic CBD exploration. After the operation, the patient was discharged with no complications. Although the rendezvous technique has not been very commonly used because several experts in the technique and a large operating room are required, this technique is a very attractive and effective approach for treating choledocholithiasis, for which endoscopic treatment is difficult.

  12. Endoscopic Sphincterotomy Using the Rendezvous Technique for Choledocholithiasis during Laparoscopic Cholecystectomy: A Case Report

    Directory of Open Access Journals (Sweden)

    Takayuki Tanaka

    2014-08-01

    Full Text Available A 50-year-old male was examined at another hospital for fever, general fatigue and slight abdominal pain. He was treated with antibiotics and observed. However, his symptoms did not lessen, and laboratory tests revealed liver dysfunction, jaundice and an increased inflammatory response. He was then admitted to our hospital and underwent an abdominal computed tomography scan and magnetic resonance cholangiopancreatography (MRCP, which revealed common bile duct (CBD stones. He was diagnosed with mild acute cholangitis. As the same time, he was admitted to our hospital and an emergency endoscopic retrograde cholangiopancreatography was performed. Vater papilla opening in the third portion of the duodenum and presence of a peripapillary duodenal diverticulum made it difficult to perform cannulation of the CBD. In addition, MRCP revealed that the CBD was extremely narrow (diameter 5 mm. We therefore performed laparoscopic cholecystectomy and endoscopic sphincterotomy using the rendezvous technique for choledocholithiasis simultaneously rather than laparoscopic CBD exploration. After the operation, the patient was discharged with no complications. Although the rendezvous technique has not been very commonly used because several experts in the technique and a large operating room are required, this technique is a very attractive and effective approach for treating choledocholithiasis, for which endoscopic treatment is difficult.

  13. The value of cholangiography through Jackson-Pratt drains in the management of postoperative biliary injuries.

    Science.gov (United States)

    Macedo, Francisco Igor B; Casillas, Victor J; Davis, James S; Levi, Joe U; Sleeman, Danny

    2014-01-01

    Iatrogenic biliary injury is the most significant complication after laparoscopic cholecystectomy. We present our experience with an alternative diagnostic approach using transcatheter cholangiography (TCC) through a Jackson-Pratt (JP) drain and discuss potential benefits and limitations of the technique. From March 2002 to February 2012, 40 patients with major postoperative biliary injury underwent biliary reconstruction at our institution. Mean age was 51.7 ± 18.1 years (range, 19 to 86 years) with 30 (75%) females. Seventeen (42.5%) injuries were detected intraoperatively and in 13 (32.5%) cases, JP drains were placed for biliary drainage. Lesions were classified according to Bismuth grade: I (10 patients [25%]), II (10 patients [25%]), III (six patients [15%]), IV (10 patients [25%]), and V (four patients [10%]). TCC was performed in seven patients with JP drains (53.8%). It fully defined the injury site in three cases of limited magnetic resonance cholangiopancreatography (MRCP) such as common hepatic duct and common bile duct leaks and in four cases (57.1%) that endoscopic retrograde cholangiopancreatography (ERCP) was limited as a result of clipping of the distal common bile duct. TCC showed promising results in cases of limited MRCP and ERCP such as fistulous orifices or leakage. It may represent an alternative adjunct in the diagnostic armamentarium of complex biliary injuries.

  14. The use of endoscopic ultrasonography in the diagnosis of the causes of common bile duct dilation

    International Nuclear Information System (INIS)

    Sajewicz, Z.; Wozniak-Stolarska, B.; Salomon, A.; Poniewierka, E.; Kempinski, R.

    2006-01-01

    Background. Ultrasonography (US) does not come up to the expectations in the diagnosis of the causes of common bile duct (CBD) dilation. Objectives. An assessment of the usefulness of endoscopic ultrasonography (EUS) in the diagnosis of the causes of CBD dilation. Material and Methods. The authors examined 30 persons (16 females and 14 males) with CBD dilated > 7 mm in US. In these patients the authors performed EUS with the usage of Pentax FG-38UX echoendoscope of 5-10 MHz frequency connected with EUB 6000 Hitachi ultrasonograph looking for the cause of CBD dilation. Findings gathered were verified with the usage of endoscopic retrograde cholangiopancreatography (ERCP) or magnetic resonance cholangiopancreatography (MRCP). Results. In 16 patients the authors found stones in CBD. In ERCP or MRCP the frequency of CBD stones was a bit higher. In these examinations CBD stones were found in 18 patients. The authors found out that pancreatic head carcinoma was the cause of CBD dilation in 8 patients; in 2 patients the authors diagnosed ampullary carcinoma and in 1 patient - carcinoma of distal part of CBD. In 1 patient the authors pointed out a benign stricture of CBD with dilation above the stricture. Conclusions. EUS is a useful diagnosing method of the causes of CBD dilation. (authors)

  15. Evaluation of pancreatic exocrine insufficiency by cine-dynamic MRCP using spatially selective inversion-recovery (IR) pulse: Correlation with severity of chronic pancreatitis based on morphological changes of pancreatic duct.

    Science.gov (United States)

    Yasokawa, Kazuya; Ito, Katsuyoshi; Kanki, Akihiko; Yamamoto, Akira; Torigoe, Teruyuki; Sato, Tomohiro; Tamada, Tsutomu

    2018-05-01

    To evaluate the correlation between the pancreatic exocrine insufficiency estimated by cine-dynamic MRCP using spatially selective IR pulse and the severity stages (modified Cambridge classification) based on morphological changes of the pancreatic duct in patients with suspected chronic pancreatitis. Thirty-nine patients with suspected chronic pancreatitis underwent cine-dynamic MRCP with a spatially selective IR pulse. The secretion grading score (5-point scale) based on the moving distance of pancreatic juice inflow on cine-dynamic MRCP was assessed, and compared with the stage of the severity of chronic pancreatitis based on morphological changes of pancreatic duct. The stage of the severity of chronic pancreatitis based on morphological changes had significant negative correlations with the secretion grade (r=-0.698, P0.70 in 2 (33%) of 6 patients showing normal pancreatic exocrine function. It should be noted that the degree of morphological changes of pancreatic duct does not necessarily reflect the severity of pancreatic exocrine insufficiency at cine-dynamic MRCP in stage 2-3 chronic pancreatitis. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Medical image of the week: ascending cholangitis from biliary obstruction

    Directory of Open Access Journals (Sweden)

    Wong C

    2013-04-01

    Full Text Available A 79 year old man with a history of quadriplegia presented to an outside hospital in septic shock. He was found to have an elevated total bilirubin of 10 mg/dL, direct bilirubin of 7 mg/dL, alkaline phosphatase of 405 U/L, and lipase of 370 U/L. Imaging showed cholelithiasis with likely intra- and extrahepatic biliary duct dilatation. The patient underwent placement of a biliary drain with clinical improvement. Additional imaging was requested prior to endoscopic retrograde cholangiopancreatography (ERCP, but magnetic resonance cholangiopancreatography (MRCP was unavailable due to metallic implants. Interventional radiology performed a cholangiogram using the biliary drain which confirmed biliary obstruction. ERCP was then performed, with significant biliary sludge found and two stents placed.

  17. MR-guided lumbar sympathicolysis

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, Claudius W.; Schott, Ulrich G.; Pereira, Philippe L.; Truebenbach, Jochen; Claussen, Claus D.; Duda, Stephan H. [Department of Diagnostic Radiology, University of Tuebingen (Germany); Schneider, Wilke [Department of Vascular Surgery, University of Tuebingen (Germany)

    2002-06-01

    The aim of this study was to demonstrate the feasibility of MR-guided lumbar sympathicolysis (LSL) in a non-selected patient population. One hundred one MR-guided LSL procedures were performed in 89 patients according to Haaga's technique using a horizontally open clinical MR system (0.2 T) and non-ferromagnetic 20-G cannulas (neurolysis, n=93; blockade, n=8). Only gradient-recalled sequences in either single or multislice mode [fast imaging with steady-state precession (FISP) and fast low-angle shot] were applied for anatomical survey and needle guiding. Bupivacaine injection was monitored with MR fluoroscopically. Fluid distribution was subsequently documented in a CT scan in 65 patients. Ninety-one LSL procedures could be successfully completed. Ten patients were not treated using MR due to patient inconvenience, severe motion artifacts (n=4 each), excessive spondylophytes, and retroperitoneal hematoma (n=1 each). One case of ureteral necrosis occurred. Motion artifacts were rated less severe in single-slice FISP sequences and in obese patients. An average of 3.48 sequence measurements were required for definitive needle placement. Average table time was 32.3 min. An MR-guided LSL is feasible and can be performed with acceptable safety and time effort. It can be recommended for repeated sympathetic blockades in younger patients to avoid cumulative irradiation associated with CT guidance. (orig.)

  18. MR-guided lumbar sympathicolysis

    International Nuclear Information System (INIS)

    Koenig, Claudius W.; Schott, Ulrich G.; Pereira, Philippe L.; Truebenbach, Jochen; Claussen, Claus D.; Duda, Stephan H.; Schneider, Wilke

    2002-01-01

    The aim of this study was to demonstrate the feasibility of MR-guided lumbar sympathicolysis (LSL) in a non-selected patient population. One hundred one MR-guided LSL procedures were performed in 89 patients according to Haaga's technique using a horizontally open clinical MR system (0.2 T) and non-ferromagnetic 20-G cannulas (neurolysis, n=93; blockade, n=8). Only gradient-recalled sequences in either single or multislice mode [fast imaging with steady-state precession (FISP) and fast low-angle shot] were applied for anatomical survey and needle guiding. Bupivacaine injection was monitored with MR fluoroscopically. Fluid distribution was subsequently documented in a CT scan in 65 patients. Ninety-one LSL procedures could be successfully completed. Ten patients were not treated using MR due to patient inconvenience, severe motion artifacts (n=4 each), excessive spondylophytes, and retroperitoneal hematoma (n=1 each). One case of ureteral necrosis occurred. Motion artifacts were rated less severe in single-slice FISP sequences and in obese patients. An average of 3.48 sequence measurements were required for definitive needle placement. Average table time was 32.3 min. An MR-guided LSL is feasible and can be performed with acceptable safety and time effort. It can be recommended for repeated sympathetic blockades in younger patients to avoid cumulative irradiation associated with CT guidance. (orig.)

  19. Vagal withdrawal during endoscopic retrograde cholangiopancreatography

    DEFF Research Database (Denmark)

    Christensen, M; Rasmussen, Verner; Schulze, S

    2000-01-01

    BACKGROUND: Patients undergoing endoscopic retrograde cholangiopancreatography (ERCP) are at risk of developing cardiorespiratory complications, but the mechanism is still unknown. Treatment with metoprolol 2 h before the endoscopy has been shown to decrease the incidence of myocardial ischaemia......: The existence of a defence-like reaction ('vagal withdrawal') during ERCP has been shown. Metoprolol given 2 h before the procedure did not affect the occurrence of this phenomenon. The interaction of other periendoscopic factors is still unclear and should be studied further....

  20. Centrically reordered inversion recovery half-Fourier single-shot turbo spin-echo sequence: improvement of the image quality of oxygen-enhanced MRI

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Hatabu, Hiroto; Higashino, Takanori; Kawamitsu, Hideaki; Watanabe, Hirokazu; Takenaka, Daisuke; Cauteren, Marc van; Sugimura, Kazuro

    2004-01-01

    Purpose: The purpose of the study presented here was to determine the improvement in image quality of oxygen-enhanced magnetic resonance (MR) subtraction imaging obtained with a centrically reordered inversion recovery half-Fourier single-shot turbo spin-echo (c-IR-HASTE) sequence compared with that obtained with a conventional sequentially reordered inversion recovery single-shot HASTE (s-IR-HASTE) sequence for pulmonary imaging. Materials and methods: Oxygen-enhanced MR imaging using a 1.5 T whole body scanner was performed on 12 healthy, non-smoking volunteers. Oxygen-enhanced MR images were obtained with the coronal two-dimensional (2D) c-IR-HASTE sequence and 2D s-IR-HASTE sequence combined with respiratory triggering. For a 256x256 matrix, 132 phase-encoding steps were acquired including four steps for phase correction. Inter-echo spacing for each sequence was 4.0 ms. The effective echo time (TE) for c-IR-HASTE was 4.0 ms, and 16 ms for s-IR-HASTE. The inversion time (TI) was 900 ms. To determine the improvement in oxygen-enhanced MR subtraction imaging by c-IR-HASTE, CNRs of subtraction image, overall image quality, and image degradation of the c-IR-HASTE and s-IR-HASTE techniques were statistically compared. Results: CNR, overall image quality, and image degradation of c-IR-HASTE images showed significant improvement compared to those s-IR-HASTE images (P<0.05). Conclusion: Centrically reordered inversion recovery half-Fourier single-shot turbo spin-echo (c-IR-HASTE) sequence enhanced the signal from the lung and improved the image quality of oxygen-enhanced MR subtraction imaging

  1. Huge biloma after endoscopic retrograde cholangiopancreatography and endoscopic biliary sphincterotomy

    Directory of Open Access Journals (Sweden)

    Harith M. Alkhateeb

    2015-01-01

    Conclusions: (1 Following endoscopic retrograde cholangiopancreatography, a patient’s complaints should not be ignored. (2 A massive biloma can occur due to such procedures. (3 Conservative treatment with minimal invasive technique can prove to be effective.

  2. Vergleich von 2D- und 3D-Sequenzen für die MRCP. Klinischer Stellenwert der einzelnen Techniken

    NARCIS (Netherlands)

    Wallnoefer, A. M.; Herrmann, K. A.; Beuers, U.; Zech, C. J.; Gourtsoyianni, S.; Reiser, M. F.; Schoenberg, S. O.

    2005-01-01

    Magnetic resonance cholangio-pancreaticograpy (MRCP) is a non-invasive imaging modality of the pancreatico-biliary system which plays an increasingly important role in the clinical and diagnostic workup of patients with biliary or pancreatic diseases. The present review is designed to give an

  3. Inaccurate preoperative imaging assessment on biliary anatomy not increases biliary complications after living donor liver transplantation

    International Nuclear Information System (INIS)

    Xu Xiao; Wei Xuyong; Ling Qi; Wang Kai; Bao Haiwei; Xie Haiyang; Zhou Lin; Zheng Shusen

    2012-01-01

    Backgrounds and aims: Accurate assessment of graft bile duct is important to plan surgical procedure. Magnetic resonance cholangiopancreatography (MRCP) has become an important diagnostic procedure in evaluation of pancreaticobiliary ductal abnormalities and has been reported as highly accurate. We aim to estimate the efficacy of preoperative MRCP on depicting biliary anatomy in living donor liver transplantation (LDLT), and to determine whether inaccurate preoperative imaging assessment would increase the biliary complications after LDLT. Methods: The data of 118 cases LDLT were recorded. Information from preoperative MRCP was assessed using intraoperative cholangiography (IOC) as the gold standard. The possible risk factors of recipient biliary complications were analyzed. Results: Of 118 donors, 84 had normal anatomy (type A) and 34 had anatomic variants (19 cases of type B, 9 cases of type C, 1 case of type E, 2 cases of type F and 3 cases of type I) confirmed by IOC. MRCP correctly predicted all 84 normal cases and 17 of 34 variant cases, and showed an accuracy of 85.6% (101/118). The incidence of biliary complications was comparable between cases with accurate and inaccurate classification of biliary tree from MRCP, and between cases with normal and variant anatomy of bile duct. While cases with graft duct opening ≤5 mm showed a significant higher incidence of total biliary complications (21.1% vs. 6.6%, P = 0.028) and biliary stricture (10.5% vs. 1.6%, P = 0.041) compared with cases with large duct opening >5 mm. Conclusion: MRCP could correctly predict normal but not variant biliary anatomy. Inaccurate assessment of biliary anatomy from MRCP not increases the rate of biliary complications, while small-sized graft duct may cause an increase in biliary complications particularly biliary stricture after LDLT.

  4. An unusual experience with endoscopic retrograde cholangiopancreatography

    Directory of Open Access Journals (Sweden)

    Mallikarjun Patil

    2013-01-01

    Full Text Available The endoscopic retrograde cholangiopancreatography (ERCP is known for its varied diagnostic and therapeutic utility for a variety of disorders. However it has greater likelihood of procedure related complications among the endoscopic procedures of gastrointestinal tract. The extraluminal hemorrhagic complications following ERCP are potentially life threatening though relatively rare. We present a 50 year patient with choledocholithiasis and cholelithiasis developing rare complication of subcapsular hepatic hematoma, following ERCP due to guide wire injury.

  5. Hilar cholangiocarcinoma: Cross sectional evaluation of disease spectrum

    Science.gov (United States)

    Mahajan, Mangal S; Moorthy, Srikanth; Karumathil, Sreekumar P; Rajeshkannan, R; Pothera, Ramchandran

    2015-01-01

    Although hilar cholangiocarcinoma is relatively rare, it can be diagnosed on imaging by identifying its typical pattern. In most cases, the tumor appears to be centered on the right or left hepatic duct with involvement of the ipsilateral portal vein, atrophy of hepatic lobe on that side, and invasion of adjacent liver parenchyma. Multi-detector computed tomography (MDCT) and magnetic resonance cholangiopancreatography (MRCP) are commonly used imaging modalities to assess the longitudinal and horizontal spread of tumor. PMID:25969643

  6. MRI and MRCP of chronic pancreatitis. 1: technique and methods; La valutazione delle pancreatiti croniche con Risonanza Magnetica e colangiopancreatografia con Risonanza Magnetica. Prima parte: aspetti tecnico-metodologici

    Energy Technology Data Exchange (ETDEWEB)

    Laghi, A.; Pavone, P.; Catalano, C.; Panebianco, V.; Luccichenti, G.; Fabiano, S.; Passariello, R. [Rome Univ. La Sapienza, Rome (Italy). Ist. di Radiologia

    1999-10-01

    Until recently, MR examinations of the pancreas were limited by motion artifacts, vascular pulsatility and poor spatial resolution. Today, new techniques have been developed, which allow to overcome these problems and provide additional information such as selective images of biliary and pancreatic ducts and vascular structures. As a complement to baseline sequences, MR cholangiopancreatography images can be acquired, possibly integrated by functional examination after secretin administration. Finally, contrast-enhanced MR angiography opens new perspectives for vascular studies, particularly for the locoregional staging of pancreatic cancer. [Italian] Lo studio del pancreas con risonanza magnetica e' stato fino a pochi anni fa limitato dagli artefatti da movimento, da pulsatilita' vascolare e dalla ridotta risoluzione spaziale. Recentemente sono state sviluppate nuove tecniche che consentono da un lato di risolvere tali problemi e dall'altro di fornire informazioni aggiuntive, quali immagini selettive delle vie biliari e del dotto pancreatico e delle strutture vascolari. Come completamento all'esame di base si possono ottenere immagini di colangiopancreatografia con RM, eventualmente integrate da prove funzionali, rappresentate dall'iniezione di secretina. Infine, le nuove tecniche di angiografia con RM con mdc, nelle quali si effettua un'acquisizione durante la prima fase di passaggio arterioso o venoso dopo introduzione rapida del mdc a livello di una vena periferica, aprono nuove prospettive per lo studio vascolare, in particolare nella stadiazione loco-regionale dei processi neoplastici.

  7. Conservative treatment of bronchobiliary fistula evaluated with magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Adžić-Vukičević Tatjana N.

    2015-01-01

    Full Text Available Introduction. Bronchobiliary fistula (BBF is a pathological communication between the bronchial system and the biliary tree that presents with bilioptysis. Many conditions can cause its development. There is still no optimal therapy for BBF. Conservative treatment is rarely indicated, as was published before in a few cases. Case report. We presented a 71-year-old Caucasian Serbian woman with BBF secondary to previous laparotomy due to multiple echinococcus liver cysts. The diagnosis was established by the presence of bilirubin and bile acids in sputum and magnetic resonance cholangiopancreatography (MRCP. A repeat MRCP performed after conservative procedure, did not reveal fistulous communication. Conclusion. We suggest that in small and less severe fistulas between the biliary and the bronchial tract, conservative treatment may be used successfully, and invasive treatment methods are not needed in all patients.

  8. Papel da ranitidina como meio de aprimorar a qualidade do exame de colangiopancreatografia por ressonância magnética The role of ranitidine in the enhancement of imaging quality in magnetic resonance cholangiopancreatography

    Directory of Open Access Journals (Sweden)

    Lucas Rios Torres

    2013-04-01

    Full Text Available OBJETIVO: Avaliar o impacto da ranitidina por via oral na qualidade do exame de colangiopancreatografia por ressonância magnética (CPRM. MATERIAIS E MÉTODOS: Trinta e dois pacientes realizaram CPRM com aquisições 3D e 2D, com três estratégias de supressão do sinal líquido gastrintestinal: a apenas em jejum; b 12 horas após ingerir 300 mg de ranitidina; c após a ingestão de solução de gadolínio. Três observadores avaliaram os estudos, atentos para o grau de visualização da árvore biliopancreática. Foi medida a concordância interobservador com o teste kappa. A diferença entre técnicas e formas de aquisição foi avaliada pela média da soma dos escores de graduação. RESULTADOS: As três estratégias de supressão do sinal líquido gastrintestinal apresentaram elevada reprodutibilidade. A supressão do sinal líquido gastrintestinal com a ranitidina foi semelhante ao jejum e ambas foram piores do que a solução de gadolínio. As aquisições 3D superaram a 2D apenas na visualização do ducto cístico e da vesícula biliar, sendo inferior ou equivalente nos demais segmentos ductais biliopancreáticos. CONCLUSÃO: O uso da ranitidina não parece justificado para aprimorar a avaliação da árvore biliopancreática em exames de CPRM. A CPRM 2D apenas em jejum permite a visualização ductal com elevada qualidade e reprodutibilidade na maioria dos casos.OBJECTIVE: To assess the impact of oral ranitidine on the imaging quality in magnetic resonance cholangiopancreatography (MRCP. MATERIALS AND METHODS: Thirty-two patients underwent MRCP with 3D and 2D acquisitions, and three strategies for suppression of the gastrointestinal fluid signal: a only at fasting; b 12 hours after ingestion of 300 mg ranitidine; c after oral administration of gadolinium solution. Three observers reviewed the images with a focus on the degree of visualization of the biliopancreatic tree. The interobserver agreement was evaluated with the kappa test

  9. MR imaging of edematous limbs in lymphatic and nonlymphatic edema

    International Nuclear Information System (INIS)

    Fujii, K.

    1994-01-01

    To evaluate the role of MR imaging in the diagnosis of edema, various types of edema were examined with MR imaging. MR imaging of edematous limbs was performed on 60 patients (lymphatic edema 48, nonlymphatic edema 12) using. T1-and T2-weighted spin-echo and shot inversion time inversion recovery sequences. Thickness and signal intensity of the cutis, subcutis and subfascia were evaluated in the images. In all 48 cases with lymphatic edema, trabecular structures suggesting dilated collateral lymphatic vessels were observed in the swollen subcutis. Two cases with nephrotic syndrome showed similar findings. In 6 cases with venous edema, fatty intensity was found in the subfascia. In the remaining 4 cases, the subcutis exhibited only water intensity. MR imaging is a potential contributor to the diagnosis of various edematous diseases. (orig./MG)

  10. Development of a novel fusion imaging technique in the diagnosis of hepatobiliary-pancreatic lesions

    International Nuclear Information System (INIS)

    Soga, Koichi; Ochiai, Jun; Miyajima, Takashi; Kassai, Kyoichi; Itani, Kenji; Yagi, Nobuaki; Naito, Yuji

    2013-01-01

    Multi-row detector computed tomography (MDCT) and magnetic resonance cholangiopancreatography (MRCP) play an important role in the imaging diagnosis of hepatobiliary-pancreatic lesions. Here we investigated whether unifying the MDCT and MRCP images onto the same screen using fusion imaging could overcome the limitations of each technique, while still maintaining their benefits. Moreover, because reports of fusion imaging using MDCT and MRCP are rare, we assessed the benefits and limitations of this method for its potential application in a clinical setting. The patient group included 9 men and 11 women. Among the 20 patients, the final diagnoses were as follows: 10 intraductal papillary mucinous neoplasms, 5 biliary system carcinomas, 1 pancreatic adenocarcinoma and 5 non-neoplastic lesions. After transmitting the Digital Imaging and Communication in Medicine data of the MDCT and MRCP images to a workstation, we performed a 3-D organisation of both sets of images using volume rendering for the image fusion. Fusion imaging enabled clear identification of the spatial relationship between a hepatobiliary-pancreatic lesion and the solid viscera and/or vessels. Further, this method facilitated the determination of the relationship between the anatomical position of the lesion and its surroundings more easily than either MDCT or MRCP alone. Fusion imaging is an easy technique to perform and may be a useful tool for planning treatment strategies and for examining pathological changes in hepatobiliary-pancreatic lesions. Additionally, the ease of obtaining the 3-D images suggests the possibility of using these images to plan intervention strategies.

  11. Advances in endoscopic retrograde cholangiopancreatography

    Directory of Open Access Journals (Sweden)

    WANG Xiangping

    2018-03-01

    Full Text Available Endoscopic retrograde cholangiopancreatography (ERCP is a well-established advanced endoscopic technique for the diagnosis and treatment of pancreatobiliary diseases. New advances have been made in the treatment concept and techniques of ERCP in recent years. This article elaborates on the recent advances in ERCP, including the application of pancreatic duct stent, non-steroidal anti-inflammatory drugs, and aggressive hydration to prevent postoperative pancreatitis, covered metal stent for the treatment of benign bile duct stenosis, intraluminal radiofrequency ablation for malignant bile duct stenosis, extracorporeal shockwave lithotripsy and covered metal stent for the treatment of chronic pancreatitis, peroral choledochoscopy for qualitative diagnosis of bile duct stenosis and huge refractory stones, definition of difficult intubation, timing of pre-cut technique, and ERCP after gastrointestinal reconstruction.

  12. Incremental value of secretin-enhanced magnetic resonance cholangiopancreatography in detecting ductal communication in a population with high prevalence of small pancreatic cysts

    International Nuclear Information System (INIS)

    Rastegar, Neda; Matteoni-Athayde, Luciana G.; Eng, John; Takahashi, Naoki; Tamm, Eric P.; Mortele, Koenraad J.; Syngal, Sapna; Margolis, Daniel; Lennon, Anne Marie; Wolfgang, Christopher L.; Fishman, Elliot K.; Hruban, Ralph H.; Goggins, Michael; Canto, Marcia I.; Kamel, Ihab R.

    2015-01-01

    Highlights: •Secretin improved visualization of ductal communication of a cystic pancreatic lesion. •No association between cysts and gender, ethnicity or type of high risk. •Incremental value of secretin could offset the added cost and time. -- Abstract: Purpose: We investigated the incremental diagnostic yield of S-MRCP in a population with high prevalence of small pancreatic cysts. Methods: Standard MRCP protocol was performed with and without secretin using 1.5 T units in subjects undergoing pancreatic screening because of a strong family history of pancreatic cancer as part of the multicenter Cancer of the Pancreas Screening-3 trial (CAPS 3). All studies were reviewed prospectively by two independent readers who recorded the presence and number of pancreatic cysts, the presence of visualized ductal communication before and after secretin, and the degree of confidence in the diagnoses. Result: Of 202 individuals enrolled (mean age 56 years, 46% males), 93 (46%) had pancreatic cysts detected by MRCP, and 64 of the 93 had pre-and post-secretin MRCP images available for comparison. Data from the 128 readings show that 6 (6/128 = 4.7%) had ductal communication visualized only on the secretin studies compared to pre-secretin studies (odds ratio 1.28, p = 0.04). In addition, there was a statistically significant increase in confidence in reporting ductal communication after secretin compared to before secretin (p < 0.0005). Conclusion: At 1.5 T MRI, the use of secretin can improve the visualization of ductal communication of cystic pancreatic lesions

  13. Incremental value of secretin-enhanced magnetic resonance cholangiopancreatography in detecting ductal communication in a population with high prevalence of small pancreatic cysts

    Energy Technology Data Exchange (ETDEWEB)

    Rastegar, Neda; Matteoni-Athayde, Luciana G.; Eng, John [Departments of Medicine (Gastroenterology) and Radiology, The Sol Goldman Pancreatic Cancer Research Center, Johns Hopkins Medical Institutions (United States); Takahashi, Naoki [Mayo Clinic (United States); Tamm, Eric P. [MD Anderson Cancer Center (United States); Mortele, Koenraad J. [Beth Israel Deaconess Medical Center (United States); Syngal, Sapna [Dana Farber Cancer Institute (United States); Margolis, Daniel [University of California, Los Angeles (United States); Lennon, Anne Marie; Wolfgang, Christopher L.; Fishman, Elliot K.; Hruban, Ralph H.; Goggins, Michael; Canto, Marcia I. [Departments of Medicine (Gastroenterology) and Radiology, The Sol Goldman Pancreatic Cancer Research Center, Johns Hopkins Medical Institutions (United States); Kamel, Ihab R., E-mail: ikamel@jhmi.edu [Departments of Medicine (Gastroenterology) and Radiology, The Sol Goldman Pancreatic Cancer Research Center, Johns Hopkins Medical Institutions (United States)

    2015-04-15

    Highlights: •Secretin improved visualization of ductal communication of a cystic pancreatic lesion. •No association between cysts and gender, ethnicity or type of high risk. •Incremental value of secretin could offset the added cost and time. -- Abstract: Purpose: We investigated the incremental diagnostic yield of S-MRCP in a population with high prevalence of small pancreatic cysts. Methods: Standard MRCP protocol was performed with and without secretin using 1.5 T units in subjects undergoing pancreatic screening because of a strong family history of pancreatic cancer as part of the multicenter Cancer of the Pancreas Screening-3 trial (CAPS 3). All studies were reviewed prospectively by two independent readers who recorded the presence and number of pancreatic cysts, the presence of visualized ductal communication before and after secretin, and the degree of confidence in the diagnoses. Result: Of 202 individuals enrolled (mean age 56 years, 46% males), 93 (46%) had pancreatic cysts detected by MRCP, and 64 of the 93 had pre-and post-secretin MRCP images available for comparison. Data from the 128 readings show that 6 (6/128 = 4.7%) had ductal communication visualized only on the secretin studies compared to pre-secretin studies (odds ratio 1.28, p = 0.04). In addition, there was a statistically significant increase in confidence in reporting ductal communication after secretin compared to before secretin (p < 0.0005). Conclusion: At 1.5 T MRI, the use of secretin can improve the visualization of ductal communication of cystic pancreatic lesions.

  14. Factors that affect the variability in heart rate during endoscopic retrograde cholangiopancreatography

    DEFF Research Database (Denmark)

    Christensen, Merete; Reinert, Rebekka; Rasmussen, Verner

    2002-01-01

    OBJECTIVE: To find out if drugs, position, and endoscopic manipulation during endoscopic retrograde cholangiopancreatography (ERCP) influence the changes in the variability of heart rate. DESIGN: Single-blind randomised trial. SUBJECTS: 10 volunteers given butyscopolamine, glucagon, or saline...

  15. Single-Shot Echo-Planar Diffusion-Weighted MR Imaging at 3T and 1.5T for Differentiation of Benign Vertebral Fracture Edema and Tumor Infiltration

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee Jin; Lee, So Yeon; Rho, Myung Ho; Chung, Eun Chul; Kim, Mi Sung; Kwon, Heon Ju; Youn, In Young [Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul 03181 (Korea, Republic of)

    2016-11-01

    To compare the apparent diffusion coefficient (ADC) value using single-shot echo-planar imaging sequences at 3T and 1.5T for differentiation of benign fracture edema and tumor infiltration of the vertebral body. A total of 46 spinal examinations were included in the 1.5T MRI group, and a total of 40 spinal examinations were included in the 3T MRI group. The ADC values of the lesion were measured and calculated. The diagnostic performance of the conventional MR image containing sagittal T2-weighted fat saturated image and each diffusion weighted image (DWI) with an ADC value with different b values were evaluated. The mean ADC value of the benign lesions was higher than that of the malignant lesions on 1.5T and 3T (p < 0.05). The sensitivity of the diagnostic performance was higher with an additional DWI in both 1.5T and 3T, but the sensitivities were similar with the addition of b values of 400 and 1000. The specificities of the diagnostic performances did not show significant differences (p value > 0.05). The diagnostic accuracies were higher when either of the DWIs (b values of 400 and 1000) was added to routine MR image for 1.5T and 3T. Statistical differences between 1.5T and 3T or between b values of 400 and 1000 were not seen. The ADC values of the benign lesions were significantly higher than those of the malignant lesions on 1.5T and 3T. There was no statistically significant difference in the diagnostic performances when either of the DWIs (b values of 400 and 1000) was added to the routine MR image for 1.5T and 3T.

  16. Signal-shot echo-planner diffusion-weighted MR imaging at 3T and 1.5T for differentiation of benign vertebral fracture edema and tumor infiltration

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee Jin; Lee, So Yeon; Rho, Myung Ho; Chung, Eun Chul; Kim, Mi Sung; Kwon, Heon Ju; Youn, In Young [Dept. of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2016-09-15

    To compare the apparent diffusion coefficient (ADC) value using single-shot echo-planar imaging sequences at 3T and 1.5T for differentiation of benign fracture edema and tumor infiltration of the vertebral body. A total of 46 spinal examinations were included in the 1.5T MRI group, and a total of 40 spinal examinations were included in the 3T MRI group. The ADC values of the lesion were measured and calculated. The diagnostic performance of the conventional MR image containing sagittal T2-weighted fat saturated image and each diffusion weighted image (DWI) with an ADC value with different b values were evaluated. The mean ADC value of the benign lesions was higher than that of the malignant lesions on 1.5T and 3T (p < 0.05). The sensitivity of the diagnostic performance was higher with an additional DWI in both 1.5T and 3T, but the sensitivities were similar with the addition of b values of 400 and 1000. The specificities of the diagnostic performances did not show significant differences (p value > 0.05). The diagnostic accuracies were higher when either of the DWIs (b values of 400 and 1000) was added to routine MR image for 1.5T and 3T. Statistical differences between 1.5T and 3T or between b values of 400 and 1000 were not seen. The ADC values of the benign lesions were significantly higher than those of the malignant lesions on 1.5T and 3T. There was no statistically significant difference in the diagnostic performances when either of the DWIs (b values of 400 and 1000) was added to the routine MR image for 1.5T and 3T.

  17. Basketball shot types and shot success in different levels of competitive basketball.

    Directory of Open Access Journals (Sweden)

    Frane Erčulj

    Full Text Available The purpose of our research was to investigate the relative frequencies of different types of basketball shots (above head, hook shot, layup, dunk, tip-in, some details about their technical execution (one-legged, two-legged, drive, cut, …, and shot success in different levels of basketball competitions. We analysed video footage and categorized 5024 basketball shots from 40 basketball games and 5 different levels of competitive basketball (National Basketball Association (NBA, Euroleague, Slovenian 1st Division, and two Youth basketball competitions. Statistical analysis with hierarchical multinomial logistic regression models reveals that there are substantial differences between competitions. However, most differences decrease or disappear entirely after we adjust for differences in situations that arise in different competitions (shot location, player type, and attacks in transition. Differences after adjustment are mostly between the Senior and Youth competitions: more shots executed jumping or standing on one leg, more uncategorised shot types, and more dribbling or cutting to the basket in the Youth competitions, which can all be attributed to lesser technical and physical ability of developing basketball players. The two discernible differences within the Senior competitions are that, in the NBA, dunks are more frequent and hook shots are less frequent compared to European basketball, which can be attributed to better athleticism of NBA players. The effect situational variables have on shot types and shot success are found to be very similar for all competitions.

  18. Basketball shot types and shot success in different levels of competitive basketball.

    Science.gov (United States)

    Erčulj, Frane; Štrumbelj, Erik

    2015-01-01

    The purpose of our research was to investigate the relative frequencies of different types of basketball shots (above head, hook shot, layup, dunk, tip-in), some details about their technical execution (one-legged, two-legged, drive, cut, …), and shot success in different levels of basketball competitions. We analysed video footage and categorized 5024 basketball shots from 40 basketball games and 5 different levels of competitive basketball (National Basketball Association (NBA), Euroleague, Slovenian 1st Division, and two Youth basketball competitions). Statistical analysis with hierarchical multinomial logistic regression models reveals that there are substantial differences between competitions. However, most differences decrease or disappear entirely after we adjust for differences in situations that arise in different competitions (shot location, player type, and attacks in transition). Differences after adjustment are mostly between the Senior and Youth competitions: more shots executed jumping or standing on one leg, more uncategorised shot types, and more dribbling or cutting to the basket in the Youth competitions, which can all be attributed to lesser technical and physical ability of developing basketball players. The two discernible differences within the Senior competitions are that, in the NBA, dunks are more frequent and hook shots are less frequent compared to European basketball, which can be attributed to better athleticism of NBA players. The effect situational variables have on shot types and shot success are found to be very similar for all competitions.

  19. The inconsistent nature of symptomatic pancreatico-jejunostomy anastomotic strictures

    Science.gov (United States)

    Demirjian, Aram N; Kent, Tara S; Callery, Mark P; Vollmer, Charles M

    2010-01-01

    Background Pancreatico-jejunostomy strictures (PJS) after pancreatiocoduodenectomy (PD) are poorly understood. Methods Patients treated for PJS were identified from all PDs (n =357) performed for all indications in our practice (2002 to 2009). Technical aspects of the original operation, as well as the presentation, management and outcomes of the resultant stricture were assessed. Results Seven patients developed a symptomatic PJS for an incidence of 2%. ‘Soft’ glands and small ducts (≤3 mm) were each present in 3/7 of the original anastomoses. Pancreatic fistula occurred in 6/7. The latency period to stricture presentation averaged 41 months. Diagnosis of PJS was confirmed by secretin magnetic resonance cholangio-pancreatography (MRCP). Therapeutic endoscopic retrograde cholangiopancreatography (ERCP) was attempted – each unsuccessfully – in four patients. All patients required operative correction of their PJS by takedown/revision of the original pancreatico-jejunal anastomoses (PJA) (n =4) ± a modified Puestow (n =2). One patient's PJS was completely inaccessible due to dense adhesions. Another patient's stricture recurred and was successfully revised with a stricturoplasty. At a mean follow-up of 25 months, all are alive, but only 4/7 are pain free. Conclusion A symptomatic PJS appears to be independent of original pathological, glandular or technical features but pancreatic fistulae may contribute. Secretin MRCP is diagnostically useful, whereas ERCP has been proven to be therapeutically ineffective. Durable resolution of symptoms after surgical revision is unpredictable. PMID:20815857

  20. Abdominal applications of 3.0-T MR imaging: comparative review versus a 1.5-T system.

    Science.gov (United States)

    Choi, Jin-Young; Kim, Myeong-Jin; Chung, Yong Eun; Kim, Ji Youn; Jones, Alun C; de Becker, Jan; van Cauteren, Marc

    2008-01-01

    With the development of dedicated receiver coils and increased gradient performance, 3.0-T magnetic resonance (MR) systems are gaining wider acceptance in clinical practice. The expected twofold increase in signal-to-noise ratio (SNR) compared with that of 1.5-T MR systems may help improve spatial resolution or increase temporal resolution when used with parallel acquisition techniques. Several issues must be considered when applying 3.0-T MR in the abdomen, including the alteration of the radiofrequency field and relaxation time, increase in energy deposition and susceptibility effects, and problems associated with motion artifacts. For the evaluation of liver lesions, higher SNR and greater resolution achieved with the 3.0-T system could translate into better detection of malignant lesions on T2-weighted images obtained with adjusted imaging parameters. For the evaluation of pancreatic and biliary diseases, high-resolution T2-weighted imaging using single-shot turbo spin-echo sequences is useful; improvement in SNR was noticeable on two-dimensional MR cholangiopancreatographic images. For the preoperative imaging of rectal cancer, a single-shot sequence is useful for dramatically decreasing imaging time while maintaining image quality. Substantial modification of examination protocols, with optimized imaging parameters and sequence designs along with ongoing development of hardware, could contribute to an increased role of the 3.0-T system for abdominal MR examinations.

  1. MR assessment of fetal pulmonary hypoplasia

    Energy Technology Data Exchange (ETDEWEB)

    Kuwashima, Shigeko; Kohno, Atsushi; Saiki, Natoru; Iimura, Fumitoshi; Kohno, Tatsuo; Hashimoto, Teisuke; Fujioka, Mutsuhisa [Dokkyo Univ. School of Medicine, Mibu, Tochigi (Japan)

    2000-08-01

    The purpose of this study is to evaluate pulmonary hypoplasia of the fetus using MRI. The subjects consisted of 36 fetuses (18 to 40 weeks' gestation). All fetuses or mothers had major anomalies diagnosed on fetal ultrasonography. MR imaging was performed with a 1.5-T magnet and HASTE (half-Fourier acquisition single-shot turbo spin-echo) sequence. MR images were evaluated with special attention to the intensity of the lung. A diagnosis of pulmonary hypoplasia was based on the clinical, surgical, and autopsy findings. All fetuses with normal pulmonary development showed high intensity in the lung, while all fetuses with pulmonary hypoplasia showed a low intensity in the lung, obscured pulmonary vessels and a small thorax. There was a close correlation between the lung intensity and pulmonary growth. MR assessment of lung intensity may facilitate the diagnosis of pulmonary hypoplasia, particularly after 26 weeks' gestation. Some of the normally developing lung showed a low intensity from 20 to 24 weeks of gestational age. The change to normal lung intensity may occur during this period. (author)

  2. Kinematic MRI using short TR single shot fast spin echo (SSFSE) in evaluating swallowing

    Energy Technology Data Exchange (ETDEWEB)

    Isogai, Satoshi; Takehara, Yasuo; Isoda, Haruo; Kodaira, Nami; Masunaga, Hatsuko; Ozawa, Fukujirou; Kaneko, Masao [Hamamatsu Univ. School of Medicine, Shizuoka (Japan); Nozaki, Atsushi; Kabasawa, Hiroyuki

    1999-03-01

    The utility of short TR single shot fast spin echo (SSFSE) MR imaging for evaluating swallowing was determined. Five healthy volunteers underwent kinematic MR imaging of swallowing with a 1.5 T MR scanner using the short TR (300 ms) SSFSE sequence. Twenty phases of sagittal sections were acquired within 6 sec, where the temporal resolution was 300 ms. For oral contrast medium, we used prune yogurt juice with Fe added. The image contrast of short TR SSFSE was found to be somewhere like that of T1-weighted images. In all cases, both the buccal and pharyngeal stages of swallowing were successfully depicted. The Fe-added prune yogurt juice performed as a positive contrast medium and helped determine anatomical structures in the buccal stage. Short TR (300 ms) SSFSE was useful in evaluating swallowing. The combined use of Fe-added prune yogurt juice was helpful in enhancing the surface of the oropharynx. (author)

  3. Kinematic MRI using short TR single shot fast spin echo (SSFSE) in evaluating swallowing

    International Nuclear Information System (INIS)

    Isogai, Satoshi; Takehara, Yasuo; Isoda, Haruo; Kodaira, Nami; Masunaga, Hatsuko; Ozawa, Fukujirou; Kaneko, Masao; Nozaki, Atsushi; Kabasawa, Hiroyuki

    1999-01-01

    The utility of short TR single shot fast spin echo (SSFSE) MR imaging for evaluating swallowing was determined. Five healthy volunteers underwent kinematic MR imaging of swallowing with a 1.5 T MR scanner using the short TR (300 ms) SSFSE sequence. Twenty phases of sagittal sections were acquired within 6 sec, where the temporal resolution was 300 ms. For oral contrast medium, we used prune yogurt juice with Fe added. The image contrast of short TR SSFSE was found to be somewhere like that of T1-weighted images. In all cases, both the buccal and pharyngeal stages of swallowing were successfully depicted. The Fe-added prune yogurt juice performed as a positive contrast medium and helped determine anatomical structures in the buccal stage. Short TR (300 ms) SSFSE was useful in evaluating swallowing. The combined use of Fe-added prune yogurt juice was helpful in enhancing the surface of the oropharynx. (author)

  4. Diffusion-weighted MR imaging of the abdomen with pulse triggering

    International Nuclear Information System (INIS)

    Muertz, P.; Pauleit, D.; Traeber, F.; Kreft, B.P.; Schild, H.H.

    2000-01-01

    Purpose: The aim of this work was to reduce the influence of motion on diffusion-weighted MR images of the abdomen by pulse triggering of single-shot sequences. Methods: Five healthy volunteers were examined both without and with finger pulse-triggering of a diffusion-weighted single-shot echo planar MR imaging sequence at 1.5 T. Series of diffusion-weighted images were acquired at different phases of the cardiac cycle by varying the time delay between finger pulse and sequence acquisition. The measurements were repeated three times. The diffusion weighted images were analysed by measuring the signal intensities and by determining the ADC values within the spleen, kidney and liver. Results: The magnitude of motion artifacts on diffusion weighted images shows a strong dependence on the trigger delay. The optimum trigger delay is found to be between 500 and 600 ms. For these values the abdominal organs appear homogeneous on all diffusion weighted images and the strongest signal intensities are detected. At optimum triggering the accuracy of the apparent diffusion coefficients is up to 10 times better than without triggering. Moreover, the standard deviation of the repeated measurements is smaller than 12% for all volunteers and for all organs. Without triggering the standard deviation is larger by a factor of 4 on average. Conclusion: Pulse triggering of single-shot sequences leads to significant reduction of motion related artifacts on diffusion weighted images of the abdomen and provides more accurate and reproducible ADC values. (orig.) [de

  5. Basketball Shot Types and Shot Success in Different Levels of Competitive Basketball

    OpenAIRE

    Er?ulj, Frane; ?trumbelj, Erik

    2015-01-01

    The purpose of our research was to investigate the relative frequencies of different types of basketball shots (above head, hook shot, layup, dunk, tip-in), some details about their technical execution (one-legged, two-legged, drive, cut, …), and shot success in different levels of basketball competitions. We analysed video footage and categorized 5024 basketball shots from 40 basketball games and 5 different levels of competitive basketball (National Basketball Association (NBA), Euroleague,...

  6. Shot-by-shot spectrum model for rod-pinch, pulsed radiography machines

    Directory of Open Access Journals (Sweden)

    Wm M. Wood

    2018-02-01

    Full Text Available A simplified model of bremsstrahlung production is developed for determining the x-ray spectrum output of a rod-pinch radiography machine, on a shot-by-shot basis, using the measured voltage, V(t, and current, I(t. The motivation for this model is the need for an agile means of providing shot-by-shot spectrum prediction, from a laptop or desktop computer, for quantitative radiographic analysis. Simplifying assumptions are discussed, and the model is applied to the Cygnus rod-pinch machine. Output is compared to wedge transmission data for a series of radiographs from shots with identical target objects. Resulting model enables variation of parameters in real time, thus allowing for rapid optimization of the model across many shots. “Goodness of fit” is compared with output from LSP Particle-In-Cell code, as well as the Monte Carlo Neutron Propagation with Xrays (“MCNPX” model codes, and is shown to provide an excellent predictive representation of the spectral output of the Cygnus machine. Improvements to the model, specifically for application to other geometries, are discussed.

  7. Shot-by-shot spectrum model for rod-pinch, pulsed radiography machines

    Science.gov (United States)

    Wood, Wm M.

    2018-02-01

    A simplified model of bremsstrahlung production is developed for determining the x-ray spectrum output of a rod-pinch radiography machine, on a shot-by-shot basis, using the measured voltage, V(t), and current, I(t). The motivation for this model is the need for an agile means of providing shot-by-shot spectrum prediction, from a laptop or desktop computer, for quantitative radiographic analysis. Simplifying assumptions are discussed, and the model is applied to the Cygnus rod-pinch machine. Output is compared to wedge transmission data for a series of radiographs from shots with identical target objects. Resulting model enables variation of parameters in real time, thus allowing for rapid optimization of the model across many shots. "Goodness of fit" is compared with output from LSP Particle-In-Cell code, as well as the Monte Carlo Neutron Propagation with Xrays ("MCNPX") model codes, and is shown to provide an excellent predictive representation of the spectral output of the Cygnus machine. Improvements to the model, specifically for application to other geometries, are discussed.

  8. Massive pleural effusion in a young woman

    Directory of Open Access Journals (Sweden)

    Paolo Ghiringhelli

    2012-12-01

    Full Text Available Pleural effusion is a clinical manifestation shared by several underlying pathologies. The differential diagnosis is based on the clinical history, the physical examination, the analysis of the pleural fluid, and the laboratory data (mainly blood tests. There are cases, such as the patient described, where TC is not enough, and unusual imaging techniques are required for the study of pleural effusion, i.e. magnetic resonance cholangiography, cholangiopancreatography (MRCP and endoscopic retrograde cholangiopancreatography (ERCP.This case analyses a 42-year-old female patient who arrived with progressive dyspnoea, chest pain, cough, a history of alcohol abuse, and a recent episode of acute pancreatitis. The physical examination revealed signs of right-sided pleural effusion. These features, together with laboratory data, made it possible to pose the diagnosis of pancreaticopleural fistula, to treat it, and to obtain a complete healing in a two-month period.

  9. Buster-Jangle Shot Dog

    International Nuclear Information System (INIS)

    Kaul, Dean C.

    1987-01-01

    Shot Dog of the Buster-Jangle Series used a device which had a high-explosive configuration virtually identical to that of the Nagasaki bomb, though with different fissionable components. Dog was detonated at a height of 431.9 m with the mean atmospheric conditions between burst and ground being dry air density 1.027 mg/cc and atmospheric moisture density 0.006 mg/cc. The ground was taken to be that of Nevada test site (NTS) area 9 with a water content of 8% by weight. The yield of the weapon was 21 kt. Results shown here for Buster-Jangle Shot Dog have been scaled from those calculated for Ranger Shot Fox. The design features and burst geometries of the two devices were deemed sufficiently similar to make this substitution in the absence of a radiation leakage spectrum calculated explicitly for Buster-Jangle Shot Dog. However, while the relative atmospheric contents of the two shots were very similar, Shot Fox took place in air of approximately 10% greater density than Shot Dog. Thus, scaled calculated results could not be obtained to compare with the three closest measurement points at Shot Dog

  10. Shot-to-shot reproducibility of a self-magnetically insulated ion diode

    International Nuclear Information System (INIS)

    Pushkarev, A. I.; Isakova, Yu. I.; Khailov, I. P.

    2012-01-01

    In this paper we present the analysis of shot to shot reproducibility of the ion beam which is formed by a self-magnetically insulated ion diode with an explosive emission graphite cathode. The experiments were carried out with the TEMP-4M accelerator operating in double-pulse mode: the first pulse is of negative polarity (300–500 ns, 100–150 kV), and this is followed by a second pulse of positive polarity (150 ns, 250–300 kV). The ion current density was 10–70 A/cm 2 depending on the diode geometry. The beam was composed from carbon ions (80%–85%) and protons. It was found that shot to shot variation in the ion current density was about 35%–40%, whilst the diode voltage and current were comparatively stable with the variation limited to no more than 10%. It was shown that focusing of the ion beam can improve the stability of the ion current generation and reduces the variation to 18%–20%. In order to find out the reason for the shot-to-shot variation in ion current density we examined the statistical correlation between the current density of the accelerated beam and other measured characteristics of the diode, such as the accelerating voltage, total current, and first pulse duration. The correlation between the ion current density measured simultaneously at different positions within the cross-section of the beam was also investigated. It was shown that the shot-to-shot variation in ion current density is mainly attributed to the variation in the density of electrons diffusing from the drift region into the A-K gap.

  11. Allergy Shots (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Allergy Shots KidsHealth / For Parents / Allergy Shots What's in ... to help a child deal with them. Why Allergy Shots Are Used An allergy occurs when the ...

  12. Simultaneous static and cine nonenhanced MR angiography using radial sampling and highly constrained back projection reconstruction.

    Science.gov (United States)

    Koktzoglou, Ioannis; Mistretta, Charles A; Giri, Shivraman; Dunkle, Eugene E; Amin, Parag; Edelman, Robert R

    2014-10-01

    To describe a pulse sequence for simultaneous static and cine nonenhanced magnetic resonance angiography (NEMRA) of the peripheral arteries. The peripheral arteries of 10 volunteers and 6 patients with peripheral arterial disease (PAD) were imaged with the proposed cine NEMRA sequence on a 1.5 Tesla (T) system. The impact of multi-shot imaging and highly constrained back projection (HYPR) reconstruction was examined. The propagation rate of signal along the length of the arterial tree in the cine nonenhanced MR angiograms was quantified. The cine NEMRA sequence simultaneously provided a static MR angiogram showing vascular anatomy as well as a cine display of arterial pulse wave propagation along the entire length of the peripheral arteries. Multi-shot cine NEMRA improved temporal resolution and reduced image artifacts. HYPR reconstruction improved image quality when temporal reconstruction footprints shorter than 100 ms were used (P cine NEMRA was slower in patients with PAD than in volunteers. Simultaneous static and cine NEMRA of the peripheral arteries is feasible. Multi-shot acquisition and HYPR reconstruction can be used to improve arterial conspicuity and temporal resolution. Copyright © 2013 Wiley Periodicals, Inc.

  13. Relationship between levels of serum creatinine and perirenal hyperintensity on heavily T2-weighted MR images

    Energy Technology Data Exchange (ETDEWEB)

    Erden, Ayse, E-mail: ayse.erden@medicine.ankara.edu.tr [Ankara University, School of Medicine, Department of Radiology, Talatpasa Bulvari, Sihhiye, 06100 Ankara (Turkey); Sahin, Burcu Savran, E-mail: bsavrans@hotmail.com [Ankara University, School of Medicine, Department of Radiology, Talatpasa Bulvari, Sihhiye, 06100 Ankara (Turkey); Orgodol, Horolsuren, E-mail: hoogii99@yahoo.com [Ankara University, School of Medicine, Department of Radiology, Talatpasa Bulvari, Sihhiye, 06100 Ankara (Turkey); Erden, Ilhan, E-mail: erden@medicine.ankara.edu.tr [Ankara University, School of Medicine, Department of Radiology, Talatpasa Bulvari, Sihhiye, 06100 Ankara (Turkey); Biyikli, Zeynep, E-mail: zeynep.biyikli@gmail.com [Ankara University, School of Medicine, Department of Biostatistics, Talatpasa Bulvari, Sihhiye, 06100 Ankara (Turkey)

    2011-11-15

    Objective: To determine the frequency of perirenal hyperintensity on heavily T2-weighted images and to evaluate its relationship with serum creatinine levels. Subjects and methods: Axial and coronal single-shot fast spin-echo images which have been originally obtained for MR cholangiopancreatography in 150 subjects were examined by two observers individually for the presence of perirenal hyperintensity. The morphologic properties of perirenal hyperintensity (peripheral rim-like, discontinuous, polar) were recorded. Chi square test was used to test whether the frequencies of bilateral perirenal hyperintensity differ significantly in subjects with high serum creatinine levels and those with normal creatinine levels. This test was also used to compare the frequencies of perirenal hyperintensity in patients with and without renal cysts and in patients with and without corticomedullary differentiation. A p value of less than 0.05 was considered to be statistically significant. Results: The perirenal hyperintensity was identified in 40 of 150 cases (26.6%) on heavily T2-weighted image. Serum creatinine levels were high in 18 of 150 cases (12%). The perirenal hyperintensity was present in 11 of 18 subjects (61%) with high serum creatinine levels and 26 of 132 subjects (19.7%) with normal creatinine levels. The difference of rates in two groups was statistically significant. Odds ratio was 6407 (95% confidence interval 2264-18,129). The frequency of perirenal hyperintensity was also significantly higher in subjects with renal cyst or cysts in whom serum creatinine levels were normal (p < 0.05) (37.5% vs. 11.8%). Conclusion: Perirenal hyperintensities are more frequent in patients with high serum creatinine levels. They are also more common in patients with simple renal cysts.

  14. Relationship between levels of serum creatinine and perirenal hyperintensity on heavily T2-weighted MR images

    International Nuclear Information System (INIS)

    Erden, Ayse; Sahin, Burcu Savran; Orgodol, Horolsuren; Erden, Ilhan; Biyikli, Zeynep

    2011-01-01

    Objective: To determine the frequency of perirenal hyperintensity on heavily T2-weighted images and to evaluate its relationship with serum creatinine levels. Subjects and methods: Axial and coronal single-shot fast spin-echo images which have been originally obtained for MR cholangiopancreatography in 150 subjects were examined by two observers individually for the presence of perirenal hyperintensity. The morphologic properties of perirenal hyperintensity (peripheral rim-like, discontinuous, polar) were recorded. Chi square test was used to test whether the frequencies of bilateral perirenal hyperintensity differ significantly in subjects with high serum creatinine levels and those with normal creatinine levels. This test was also used to compare the frequencies of perirenal hyperintensity in patients with and without renal cysts and in patients with and without corticomedullary differentiation. A p value of less than 0.05 was considered to be statistically significant. Results: The perirenal hyperintensity was identified in 40 of 150 cases (26.6%) on heavily T2-weighted image. Serum creatinine levels were high in 18 of 150 cases (12%). The perirenal hyperintensity was present in 11 of 18 subjects (61%) with high serum creatinine levels and 26 of 132 subjects (19.7%) with normal creatinine levels. The difference of rates in two groups was statistically significant. Odds ratio was 6407 (95% confidence interval 2264-18,129). The frequency of perirenal hyperintensity was also significantly higher in subjects with renal cyst or cysts in whom serum creatinine levels were normal (p < 0.05) (37.5% vs. 11.8%). Conclusion: Perirenal hyperintensities are more frequent in patients with high serum creatinine levels. They are also more common in patients with simple renal cysts.

  15. Imaging of blunt pancreatic trauma: The value of initial and sequential CT examinations

    International Nuclear Information System (INIS)

    Szmigielski, W.; Darweesh, A.; Kassem, H.; Alhilli, S.

    2008-01-01

    The purpose of the study was to assess the value of initial, repeated and sequential computed tomography (CT) in patients with blunt pancreatic trauma, and then define and correlate CT findings with endoscopic retrograde cholangiopancreatography (ERCP) or magnetic resonance cholangiopancreatography (MRCP), ultrasound (US), both laboratory and surgical findings. This retrospective study covers an eight-year period from 1999 to 2007. The material includes 21 patients (17 males and 4 females) with confirmed pancreatic injury. CT was performed on admission in all cases and in 15 cases follow-up CT was performed from 24 hrs to 14 days later. US was performed in 9 cases, ERCP in 8 cases and MRCP in one case. Serum amylase level was obtained at the admission in all cases. The CT at admission was positive in 17 patients (81.0%); the diagnosis was missed in 4 patients (19.0%), all performed on single row spiral CT. In all these four cases repeated CT was positive. ERCP showed rupture of the main pancreatic duct in 7 cases, one was inconclusive. One MRCP was positive. The serum amylase was elevated in 14 cases (66.7%) Specific CT features in initial and repeated examinations together were: organ fracture - 33.3%, swelling - 38.1%, haematoma/ contusion - 38.1%, fluid between splenic vein and pancreas - 19.0%. Non-specific features were: thickening of anterior-renal fascia- 23.8%, fluid in lesser sac - 28.6%, extra peritoneal fluid - 42.9%, associated splenic injury -14.3% and intraperitoneal fluid - 38.1%. On retrospective analysis, two out of four false negative CT results could have been avoided. No correlation between the CT features and the outcome of surgical and conservative management could be found in this study. A proper technique and accurate reading of images are mandatory for the diagnosis of pancreatic injury. When CT performed on admission is negative and there is abdominal pain and an elevated serum amylase, CT examination should be repeated within 24-48 hours

  16. Is the 'Trondsen Discriminant Function' useful in patients referred for endoscopic retrograde cholangiopancreatography?

    DEFF Research Database (Denmark)

    Ainsworth, A P; Pless, T; Mortensen, M B

    2003-01-01

    BACKGROUND: Ideally, patients should only be referred to endoscopic retrograde cholangiopancreatography (ERCP) if therapy is indicated. The aim of this study was to evaluate whether or not the 'Trondsen Discriminant Function' (DF) could be used for selecting patients directly for ERCP. METHODS...

  17. Is the 'Trondsen Discriminant Function' useful in patients referred for endoscopic retrograde cholangiopancreatography?

    DEFF Research Database (Denmark)

    Ainsworth, A P; Pless, T; Mortensen, M B

    2003-01-01

    BACKGROUND: Ideally, patients should only be referred to endoscopic retrograde cholangiopancreatography (ERCP) if therapy is indicated. The aim of this study was to evaluate whether or not the 'Trondsen Discriminant Function' (DF) could be used for selecting patients directly for ERCP. METHODS: T...

  18. Generalised shot noise Cox processes

    DEFF Research Database (Denmark)

    Møller, Jesper; Torrisi, Giovanni Luca

    2005-01-01

    We introduce a class of cox cluster processes called generalised shot noise Cox processes (GSNCPs), which extends the definition of shot noise Cox processes (SNCPs) in two directions: the point process that drives the shot noise is not necessarily Poisson, and the kernel of the shot noise can...

  19. MR imaging of the central nervous system in infants and children with Gd-DTPA

    International Nuclear Information System (INIS)

    Baierl, P.; Bauer, W.M.; Forster, C.; Haustein, J.

    1988-01-01

    Twenty-five infants and children (aged 2 - 12 years) were examined with MR imaging at 1.0 T. Most of them were younger than 6 years, and general anesthesia was required for the recording of the images. Gd-DTPA was given in doses of 0.1 mmol/kg (Schering). The native MR images were followed by short flip-angle sequences (fast low-angle shot [FLASH] during the flow of Gd-DTPA. After that, T1-weighted images demonstrated contrast enhancement best. No severe adverse effects were seen. The sensitivity of plain MR imaging could not be improved by Gd-DTPA, but contrast enhancement of a lesion proved to be important for the differential diagnosis

  20. Cytology evaluation for brushing in biliary and pancreatic stenosis during endoscopic cholangiopancreatography

    International Nuclear Information System (INIS)

    Ruiz, Mario H; Castano, Rodrigo; Alvarez, Oscar A; Velez, Alejandro; Munera, Veronica

    2002-01-01

    No surgical pathologic confirmation of malignant bile duct strictures is desirable for defining subsequent treatment and prognosis. Endoscopic retrograde cholangiopancreatography is frequently performed in patients suspected of having pancreaticobiliary obstruction, but there exists no standardized method or instruments for defining benign or malignant nature of obstructing lesions by ERCP. We prospectively evaluated the yields of endoscopic retrograde brush cytology for the diagnosis of malignant bile and pancreatic duct strictures. Fluoroscopically guided endobiliary brush cytology was performed during endoscopic retrograde cholangiopancreatography in 29 consecutive patients, 20 with malignant strictures and 9 with benign stricture. A single pathologist classified the results of these studies as positive, or negative for malignancy. The sensitivities of the procedure were 69%. Specificity proved excellent, 100%. Two major complications that occurred in the same patient were acute pancreatitis in a patient with chronic pancreatitis and bleeding from pancreatic duct. Both were managed medically and improved. This study indicates that endoscopic retrograde brush cytology alone may be sufficient in daily practice, to differentiate against benign and malignant biliary or pancreatic stenosis

  1. Birth Control Shot

    Science.gov (United States)

    ... Health Food & Fitness Diseases & Conditions Infections Drugs & Alcohol School & Jobs Sports Expert Answers (Q&A) Staying Safe Videos for Educators Search English Español Birth Control Shot KidsHealth / For Teens / Birth Control Shot What's ...

  2. Clinical methods for single-shot instant MR imaging of the heart

    International Nuclear Information System (INIS)

    Cohen, M.S.; Weisskoff, R.; Rzedzian, R.

    1989-01-01

    The authors have compared cardiac protocols for instant MR methods that acquire complete images in 32 msec. Four protocols are compared: continuous scanning at a fixed TR with retrospective reordering; pseudogating by using a TR 50 msec greater than the R-R interval; progressive time delay (PTD), in which the delay from the R wave is electronically advanced; and real-time (RT) imaging at 16 images/sec, which enabled complete movies to be obtained in a single heartbeat. Spin-echo techniques have been used for the first three protocols; the RT method used gradient echoes

  3. Shot Automation for the National Ignition Facility

    International Nuclear Information System (INIS)

    Lagin, L J; Bettenhausen, R C; Beeler, R G; Bowers, G A; Carey, R.; Casavant, D.D.; Cline, B.D.; Demaret, R.D.; Domyancic, D.M.; Elko, S.D.; Fisher, J.M.; Hermann, M.R.; Krammen, J.E.; Kohut, T.R.; Marshall, C.D.; Mathisen, D.G.; Ludwigsen, A.P.; Patterson, Jr. R.W.; Sanchez, R.J.; Stout, E.A.; Van Arsdall, P.J.; Van Wonterghem, B.M.

    2005-01-01

    A shot automation framework has been developed and deployed during the past year to automate shots performed on the National Ignition Facility (NIF) using the Integrated Computer Control System This framework automates a 4-8 hour shot sequence, that includes inputting shot goals from a physics model, set up of the laser and diagnostics, automatic alignment of laser beams and verification of status. This sequence consists of set of preparatory verification shots, leading to amplified system shots using a 4-minute countdown, triggering during the last 2 seconds using a high-precision timing system, followed by post-shot analysis and archiving. The framework provides for a flexible, model-based execution driven of scriptable automation called macro steps. The framework is driven by high-level shot director software that provides a restricted set of shot life cycle state transitions to 25 collaboration supervisors that automate 8-laser beams (bundles) and a common set of shared resources. Each collaboration supervisor commands approximately 10 subsystem shot supervisors that perform automated control and status verification. Collaboration supervisors translate shot life cycle state commands from the shot director into sequences of ''macro steps'' to be distributed to each of its shot supervisors. Each Shot supervisor maintains order of macro steps for each subsystem and supports collaboration between macro steps. They also manage failure, restarts and rejoining into the shot cycle (if necessary) and manage auto/manual macro step execution and collaborations between other collaboration supervisors. Shot supervisors execute macro step shot functions commanded by collaboration supervisors. Each macro step has database-driven verification phases and a scripted perform phase. This provides for a highly flexible methodology for performing a variety of NIF shot types. Database tables define the order of work and dependencies (workflow) of macro steps to be performed for a

  4. Diclofenac Is Associated With a Reduced Incidence of Post–Endoscopic Retrograde Cholangiopancreatography Pancreatitis

    DEFF Research Database (Denmark)

    Leerhøy, Bonna; Nordholm-Carstensen, Andreas; Novovic, Srdan

    2014-01-01

    OBJECTIVE: The aim of this study was to assess the clinical effect of diclofenac administered as a single dose for the prevention of postprocedure pancreatitis in a consecutive series of patients who had undergone endoscopic retrograde cholangiopancreatography (ERCP). METHODS: Patients with a nat......OBJECTIVE: The aim of this study was to assess the clinical effect of diclofenac administered as a single dose for the prevention of postprocedure pancreatitis in a consecutive series of patients who had undergone endoscopic retrograde cholangiopancreatography (ERCP). METHODS: Patients...... with a native papilla Vateri subjected to ERCP during 2010 (control group, n = 218) and 2012 (diclofenac group, n = 182) were included. Patients with a history of chronic pancreatitis or recent acute pancreatitis were excluded. From January 2012, a rectal suppository containing 100 mg of diclofenac...... patients in the diclofenac group (P = 0.002). Moderate to severe pancreatitis occurred in 22 (10.1%) of the 218 patients in the control group versus 8 (4.4%) of the 182 patients in the diclofenac group (P = 0.036). CONCLUSIONS: This controlled cohort study suggests that the implementation of a single dose...

  5. Pancreas divisum: Analysis and therapeutic alternatives with a case report

    Directory of Open Access Journals (Sweden)

    Jokić Radoica

    2013-01-01

    Full Text Available Introduction. Pancreas divisum is a relatively common pancreatic duct anatomic variant, firstly described in the 17th century. Case report. We reported a 2-year-old child admitted to the Pediatric Clinic with breathing difficulties and abdominal pains. Examination and X-ray image, showed a vast right hydrothorax containing rusty coloured solution with a high degree of amylase. Ultrasound and computed tomography examination revealed pancreatic polycyclic pseudocysts; following magnetic resonance cholangiopancreatography (MRCP, the diagnosis of pancreas divisum was confirmed. The general condition of the patient worsened, requiring an urgent operation. External drainage of the perforated pancreatic pseudocyst was performed. Following external fistula maturation, a change from external to internal drainage was performed using Roux-en-Y fistulojejunostomy. A 3-year postoperative period was uneventful. Conclusion. Pancreas divisum cases are unique requiring clinical experience, rational approach, and complex multimodal management. MRCP is a valuable diagnostic method. Amongst therapeutic options, outer and internal drainage can be seen as reliable methods. Further investigations are absolutely required to determine practical and appropriate conclusions.

  6. Fast MR imaging and ultrafast MR imaging of fetal central nervous system abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Shakudo, Miyuki; Manabe, Takao; Murata, Katsuko; Matsuo, Ryoichi; Oda, Junro [Osaka City General Hospital (Japan); Inoue, Yuichi; Mochizuki, Kunizo; Yamada, Ryusaku

    2001-12-01

    The aims of this study were two: to compare the efficacy of fast MRI (breath-hold fast spin-echo T2-weighted and fast gradient-echo T1-weighted sequence) and ultrafast MRI (half-Fourier acquisition single-shot turbo spin-echo sequence) in evaluation of fetal central nervous system (CNS) abnormalities at late gestational age, and to compare the capability of fast MRI and ultrafast MRI to assess fetal CNS abnormalities with that of prenatal ultrasonography (US). Forty-nine women with fetuses at gestational ages of 26-39 weeks underwent fast MRI (29 patients) or ultrafast MRI (20 patients). In detection of motion artifact, visualization of the lateral and 4th ventricles, and differentiation between gray and white matter in cerebral hemispheres, ultrafast MRI was significantly superior to fast MRI (p<0.0001, Mann-Whitney U test). In 25 of 43 cases, US and MR diagnoses were the same and consistent with postnatal diagnosis. In 10 of 43 cases, MRI demonstrated findings additional to or different from those of US, and MR findings were confirmed postnatally. MRI, particularly ultrafast MRI, is useful for demonstrating CNS abnormalities in situations in which US is suggestive but not definitive. (author)

  7. Choledochal cyst: Comparison of MR and conventional cholangiography

    International Nuclear Information System (INIS)

    Kim, S.H.; Lim, J.H.; Yoon, H.-K.; Han, B.K.; Lee, S.K.; Kim, Y.I.

    2000-01-01

    AIMS: To assess the diagnostic value of magnetic resonance (MR) cholangiography versus conventional cholangiography in patients with choledochal cyst and to determine whether MR cholangiography can be considered an alternative to conventional cholangiography. MATERIALS AND METHODS: Thirteen patients with choledochal cyst were examined by MR cholangiography and conventional cholangiograms. Magnetic resonance cholangiography employed T2-weighted axial and coronal fast spin-echo, single and multislab single-shot fast spin-echo sequences, including source images with maximum intensity projections. The diagnostic value of MR cholangiography and conventional cholangiograms was assessed and compared using the criteria of depiction of morphology, anomalous pancreaticobiliary duct union and demonstration of complications such as stones. A four-point diagnostic scale was applied to the delineation of the ductal anatomy with the Wilcoxon signed-ranks test and McNemar's test used for statistical analysis. RESULTS: The depiction of the choledochal cyst was significantly better with MR cholangiography than with conventional cholangiography (P 0.03). The detection rate of an anomalous pancreaticobiliary duct union was not significantly different with either method (P = 0.641), nor was the detection rate of bile duct stones (P = 0.375). CONCLUSION: Magnetic resonance cholangiography provides data equivalent to or superior to those from conventional cholangiography in evaluating choledochal cyst. Magnetic resonance cholangiography is recommended as a non-invasive examination of choice for the evaluation of choledochal cyst. Kim, S.H. (2000). Clinical Radiology 55, 378-383

  8. MR imaging in the diagnosis of intracranial infections, inflammations and AIDS

    International Nuclear Information System (INIS)

    Henkes, H.; Schoerner, W.; Felix, R.

    1988-01-01

    At present there is limited experience with MR imaging in infectious and inflammatory diseases of the brain. The purpose of this study was to compare the diagnostic sensitivity of MR imaging and CT in presumed or proved cases of cerebral infection, inflammation, or intracranial manifestation of the acquired immunodeficiency syndrome (AIDS). Third-generation CT scanners were used to obtain plain and Gd-DTPA-enhanced scans. A 0.5-T Magnetom MR imager was used to obtain plain and contrast-enhanced T1-weighted, T1/T2-weighted, and T2-weighted images with spin-echo and fast low-angle shot (FLASH) techniques. Group 1 (immunocompetent) included 35 patients (63 examinations), group 2 (AIDS), 78 (115 examinations). Diagnoses in both groups yielded a wide range of etiologies (e.g., group 1: sarcoidosis, herpes encephalitis, meningitis, neurocysticercosis, Jakob-Creutzfeldt disease, tuberculosis, virus encephalitis; group 2: toxoplasmosis, progressive diffuse leukoencephalopathia (PDL), progressive multifocal leukoencephalopathia (PML), meningitis

  9. Dynamic MR cardiac perfusion studies in patients with acquired heart diseases

    International Nuclear Information System (INIS)

    Finelli, D.A.; Adler, L.P.; Paschal, C.B.; Haacke, E.M.

    1990-01-01

    The combination of ultrafast scanning techniques with contrast administration has opened new venues for MR imaging relating to the physiology of organ perfusion. Regional cardiac perfusion determinations lend important additional information to the morphologic and functional data provided by conventional cardiac MR imaging. The authors of this paper studied 10 patients with acquired heart diseases, including ischemic heart disease, cardiomyopathy, ventricular hypertrophy, and cardiac tumor, using conventional spin-echo imaging, cine gradient-echo imaging, and dynamic Gd-DTPA--enhanced perfusion imaging with an ultrafast, inversion-recovery, Turbo-fast low-angle shot sequence. This technique enables analysis of the first pass and early biodistribution phases following contrast administration, information that has been correlated with cardiac catheterization, single photo emission CT (SPECT), and administration emission tomographic (PET) data

  10. 78 FR 65573 - Migratory Bird Hunting; Application for Approval of Copper-Clad Iron Shot and Fluoropolymer Shot...

    Science.gov (United States)

    2013-11-01

    ... shot, causing sediment/soil and water contamination and the direct ingestion of shot by aquatic and.... Shot[supreg]. * Coatings of copper, nickel, tin, zinc, zinc chloride, zinc chrome, and fluoropolymers...

  11. The Problem of Shot Selection in Basketball

    Science.gov (United States)

    Skinner, Brian

    2012-01-01

    In basketball, every time the offense produces a shot opportunity the player with the ball must decide whether the shot is worth taking. In this article, I explore the question of when a team should shoot and when they should pass up the shot by considering a simple theoretical model of the shot selection process, in which the quality of shot opportunities generated by the offense is assumed to fall randomly within a uniform distribution. Within this model I derive an answer to the question “how likely must the shot be to go in before the player should take it?” and I show that this lower cutoff for shot quality depends crucially on the number of shot opportunities remaining (say, before the shot clock expires), with larger demanding that only higher-quality shots should be taken. The function is also derived in the presence of a finite turnover rate and used to predict the shooting rate of an optimal-shooting team as a function of time. The theoretical prediction for the optimal shooting rate is compared to data from the National Basketball Association (NBA). The comparison highlights some limitations of the theoretical model, while also suggesting that NBA teams may be overly reluctant to shoot the ball early in the shot clock. PMID:22295109

  12. The problem of shot selection in basketball.

    Directory of Open Access Journals (Sweden)

    Brian Skinner

    Full Text Available In basketball, every time the offense produces a shot opportunity the player with the ball must decide whether the shot is worth taking. In this article, I explore the question of when a team should shoot and when they should pass up the shot by considering a simple theoretical model of the shot selection process, in which the quality of shot opportunities generated by the offense is assumed to fall randomly within a uniform distribution. Within this model I derive an answer to the question "how likely must the shot be to go in before the player should take it?" and I show that this lower cutoff for shot quality f depends crucially on the number n of shot opportunities remaining (say, before the shot clock expires, with larger n demanding that only higher-quality shots should be taken. The function f(n is also derived in the presence of a finite turnover rate and used to predict the shooting rate of an optimal-shooting team as a function of time. The theoretical prediction for the optimal shooting rate is compared to data from the National Basketball Association (NBA. The comparison highlights some limitations of the theoretical model, while also suggesting that NBA teams may be overly reluctant to shoot the ball early in the shot clock.

  13. The problem of shot selection in basketball.

    Science.gov (United States)

    Skinner, Brian

    2012-01-01

    In basketball, every time the offense produces a shot opportunity the player with the ball must decide whether the shot is worth taking. In this article, I explore the question of when a team should shoot and when they should pass up the shot by considering a simple theoretical model of the shot selection process, in which the quality of shot opportunities generated by the offense is assumed to fall randomly within a uniform distribution. Within this model I derive an answer to the question "how likely must the shot be to go in before the player should take it?" and I show that this lower cutoff for shot quality f depends crucially on the number n of shot opportunities remaining (say, before the shot clock expires), with larger n demanding that only higher-quality shots should be taken. The function f(n) is also derived in the presence of a finite turnover rate and used to predict the shooting rate of an optimal-shooting team as a function of time. The theoretical prediction for the optimal shooting rate is compared to data from the National Basketball Association (NBA). The comparison highlights some limitations of the theoretical model, while also suggesting that NBA teams may be overly reluctant to shoot the ball early in the shot clock.

  14. [New guidelines on chronic pancreatitis : interdisciplinary treatment strategies].

    Science.gov (United States)

    Lerch, M M; Bachmann, K A; Izbicki, J R

    2013-02-01

    Chronic pancreatitis is a common disorder associated with significant morbidity and mortality. Interdisciplinary consensus guidelines have recently updated the definitions and diagnostic criteria for chronic pancreatitis and provide a critical assessment of therapeutic procedures. Diagnostic imaging relies on endoscopic ultrasound (EUS) as the most sensitive technique, whereas computed tomography (CT) and magnetic resonance imaging (MRI)/magnetic resonance cholangiopancreatography (MRCP) remain a frequent preoperative requirement. Endoscopic retrograde cholangiopancreatography (ERCP) is now used mostly as a therapeutic procedure except for the differential diagnosis of autoimmune pancreatitis. Complications of chronic pancreatitis, such as pseudocysts, duct stricture and intractable pain can be treated with endoscopic interventions as well as open surgery. In the treatment of pseudocysts endoscopic drainage procedures now prevail while pain treatment has greater long-term effectiveness following surgical procedures. Currently, endocopic as well as surgical treatment of chronic pancreatitis require an ever increasing degree of technical and medical expertise and are provided increasingly more often by interdisciplinary centres. Surgical treatment is superior to interventional therapy regarding the outcome of pain control and duodenum-preserving pancreatic head resection is presently the surgical procedure of choice.

  15. Added value of gadoxetic acid-enhanced T1-weighted magnetic resonance cholangiography for the diagnosis of post-transplant biliary complications

    Energy Technology Data Exchange (ETDEWEB)

    Kinner, Sonja [University of Wisconsin School of Medicine and Public Health, Department of Radiology, Madison, WI (United States); University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Schubert, Tilman B. [University of Wisconsin School of Medicine and Public Health, Department of Radiology, Madison, WI (United States); Basel University Hospital, Clinic of Radiology and Nuclear Medicine, Basel (Switzerland); Said, Adnan [University of Wisconsin-Madison, Department of Medicine, Madison, WI (United States); Mezrich, Joshua D. [University of Wisconsin-Madison, Department of Surgery, Madison, WI (United States); Reeder, Scott B. [University of Wisconsin School of Medicine and Public Health, Department of Radiology, Madison, WI (United States); University of Wisconsin-Madison, Department of Medicine, Madison, WI (United States); University of Wisconsin-Madison, Department of Biomedical Engineering, Madison, WI (United States); University of Wisconsin-Madison, Department of Medical Physics, Madison, WI (United States); University of Wisconsin-Madison, Department of Emergency Medicine, Madison, WI (United States)

    2017-10-15

    Biliary complications after liver transplantation (LT) are common. This study aimed to ascertain the value of gadoxetic acid-enhanced T1-weighted (T1w) magnetic resonance cholangiography (MRC) to evaluate anastomotic strictures (AS), non-anastomotic strictures (NAS) and biliary casts (BC). Sixty liver-transplanted patients with suspicion of biliary complications and T2w-MRCP and T1w-MRC followed by endoscopic retrograde cholangiopancreatography (ERCP) or percutaneous transhepatic cholangiography (PTC) were analysed. Two readers reviewed the MRCs and rated image quality (IQ) and likelihood for AS/NAS/BC on Likert scales. Sensitivity, specificity and predictive values were calculated, ROC curve analysis performed, and inter-reader variability assessed. The subjective added value of T1w-MRC was rated. IQ was high for all sequences without significant differences (2.83-2.88). In 39 patients ERCP/PTC detected a complication. Sensitivity and specificity for AS were 64-96 using T2w-MRCP, increasing to 79-100 using all sequences. Use of all sequences increased the sensitivity of detecting NAS/BC from 72-92% to 88-100% and 67-89% to 72-94%, respectively. Kappa values were substantial (0.45-0.62). T1w-MRC was found to be helpful in 75-83.3%. Combining T1w-MRC and T2w-MRCP increased sensitivity and specificity and diagnostic confidence in patients after LT with suspected biliary complications. T1w-MRC is a valuable tool for evaluating post-transplant biliary complications. (orig.)

  16. Diagnosis and treatment with endoscopic retrograde cholangiopancreatography

    International Nuclear Information System (INIS)

    Soendenaa, K.; Horn, A.; Viste, A.

    1994-01-01

    Endoscopic retrograde cholangiopancreatography (ERCP) was carried out for the first time in 1968. Five years later endoscopic sphincterotomy was performed. Since then both modalities have become established as necessary adjuncts in the diagnosis and treatment of patients with pathology in the bile duct or pancreas. The main indication is common bile duct stone, and as a consequence of this treatment fewer patients are now treated surgically. Patients with malignant bile duct obstruction can be given reasonable palliation of both jaundice and pruritus and therefore improved quality of life. Some reports indicate that endoscopic drainage may be useful for pancreatic stenosis. Complications are few, but vigilance and prompt treatment is necessary to keep morbidity at a minimum. Follow-up after several years shows that sphincterotomy is successful also in the long term. The authors discuss the present diagnostic and therapeutic situation. 31 refs., 2 tabs

  17. Intestinal lesions in pediatric Crohn disease: comparative detectability among pulse sequences at MR enterography

    International Nuclear Information System (INIS)

    Sohn, Beomseok; Kim, Myung-Joon; Lee, Mi-Jung; Koh, Hong; Han, Kyung Hwa

    2014-01-01

    Variable sequences can be used in MR enterography, and no consensus exists for the best protocol in children with Crohn disease. To compare the lesion detectability of various MR enterography sequences and to correlate the findings of these sequences with the Pediatric Crohn's Disease Activity Index (PCDAI) in children with Crohn disease. Children with clinically or pathologically confirmed Crohn disease underwent MR enterography, including a single-shot fast spin-echo (SSFSE) sequence, motility imaging (coronal 2-D balanced fast field echo), diffusion-weighted imaging (DWI), and dynamic contrast enhancement imaging (including arterial, portal and delayed phases). The lesion detectability of each sequence was graded 0-2 for each involved bowel segment. The lesion detectability and PCDAI result on different sequences were compared using the weighted least squares method and Student's t-test, respectively. Fifteen children (11 boys, 4 girls, mean age 13.7 ± 1.4 years) with a total of 41 lesions were included in this study. All lesions detected in more than two sequences were visible on the single-shot fast spin-echo (SSFSE) sequence. The relative lesion detection rate was 78.1% on motility imaging, 90.2% on DWI, and 92.7% on arterial, 95.1% on portal and 95.1% on delayed phase imaging. Compared to the SSFSE sequence, motility imaging (P < 0.001) and DWI (P = 0.039) demonstrated lower detectability. The mean PCDAI result in the detected lesions was statistically higher only on dynamic enhancement imaging (P < 0.001). All MR enterography sequences were found to have relatively high lesion detectability in children with Crohn disease, while motility imaging showed the lowest lesion detectability. Lesions detected on dynamic enhancement imaging showed a higher PCDAI result, which suggests that this sequence is specific for active inflammation. (orig.)

  18. Pancreatitis. An update; Pankreatitis. Ein Update

    Energy Technology Data Exchange (ETDEWEB)

    Schreyer, A.G. [Universitaetsklinikum Regensburg, Institut fuer Roentgendiagnostik, Regensburg (Germany); Grenacher, L. [Diagnostik Muenchen, MVZ Radiologie, Muenchen (Germany); Juchems, M. [Klinikum Konstanz, Diagnostische und Interventionelle Radiologie, Konstanz (Germany)

    2016-04-15

    Acute and chronic pancreatitis are becoming increasingly more severe diseases in the western world with far-reaching consequences for the individual patient as well as the socioeconomic situation. This article gives an overview of the contribution of radiological imaging to the diagnostics and therapy of both forms of the disease. Acute pancreatitis can be subdivided into severe (20 %) and mild manifestations. The diagnostics should be performed with computed tomography (CT) or magnetic resonance imaging (MRI) for assessing necrosis or potential infections only in severe forms of pancreatitis. In chronic pancreatitis transabdominal ultrasound should initially be adequate for assessment of the pancreas. For the differential diagnosis between pancreatic carcinoma and chronic pancreatitis, MRI with magnetic resonance cholangiopancreatography (MRCP) followed by an endoscopic ultrasound-guided fine needle aspiration is the method of choice. For the primary diagnosis for acute and chronic pancreatitis ultrasound examination is the modality of first choice followed by radiological CT and MRI with MRCP examinations. (orig.) [German] Akute und chronische Pankreatitis sind in der westlichen Welt zunehmende schwere Krankheitsbilder mit tiefgreifenden Konsequenzen fuer den einzelnen Patienten sowie soziooekonomisch. Der Beitrag radiologischer Bildgebung zur Diagnostik und Therapie beider Erkrankungsformen soll im vorliegenden Uebersichtsbeitrag diskutiert werden. Die akute Pankreatitis kann in eine schwere (20 %) und milde Verlaufsform unterteilt werden. Lediglich bei den schweren Formen sollte eine CT- oder MRT-Diagnostik bzgl. der Beurteilung von Nekrosen und moeglichen Infektionen erfolgen. Bei der chronischen Pankreatitis genuegt zunaechst eine Beurteilung des Pankreas durch transabdominellen Ultraschall. Hier sind die MRT mit der Magnetresonanzcholangiopankreatikographie (MRCP) sowie die endosonographisch gesteuerte Feinnadelpunktion die Methode, um

  19. Shot peening: theory applications and recent development

    International Nuclear Information System (INIS)

    Zaid, A.I.O.

    1999-01-01

    Shot peening is a surface treatment process by which the surface of an elastic-plastic target material is subjected to multiple impact by spherical shots made of glass or hard steel in a defined and controlled manner. The multiple impact produces a dynamic compressive stress at the surface of the target, thereby effectively improving its mechanical behavior and eliminates cracks and imperfections hence improving the fatigue life and strength. In this paper, the theory and practice of the shot peening process are reviewed. The main parameters involved in the process and their effects on shot peening are presented and discussed which include: shot material, size and geometry, shot pressure and shot velocity, projection angle, exposure time, table rotational speed, standoff distance coverage, saturation and peening intensity. Furthermore, the effect of shot peening on fatigue life and fatigue strength of ferrous and non-ferrous materials together with other different industrial applications of the process are given. Recent developments in utilizing the shot peening process with welded parts and hard chromium plating aiming at improvement of their fatigue strength and their resistance to stress corrosion cracking are also presented and discussed. Finally, future development of the process are outlined and discussed. (author)

  20. Assembly procedure for Shot Loading Platform

    International Nuclear Information System (INIS)

    Routh, R.D.

    1995-01-01

    This supporting document describes the assembly procedure for the Shot Loading Platform. The Shot Loading Platform is used by multiple equipment removal projects to load shielding shot in the annular spaces of the equipment storage containers. The platform height is adjustable to accommodate different sizes of storage containers and transport assemblies

  1. Clinical value of diffusion-weighted MR imaging in acute contusion of spinal cord

    International Nuclear Information System (INIS)

    Zhang Jinsong; Huan Yi; Sun Lijun; Zhao Haitao; Ge Yali; Chang Yingjuan; Yang Chunmin

    2005-01-01

    Objective: To study the clinical value of diffusion-weighted MR imaging (DWI) in acute contusion of spinal cord. Methods: Eighteen cases with acute contusion of spinal cord were examined with routine MRI and DWI, including single-shot DWI (ssh-DWI) in 2 cases and multi-shot DWI (msh-DWI) in 16 cases, on a 1.5-tesla MR system within 72 h post-trauma. Results: Two cases examined by ssh-DWI showed local lesions with significant high signals, but ssh-DWI images could not be used to measure apparent diffusion coefficient (ADC) value due to its weak resolution. Other 16 cases examined by msh-DWI showed better images and were classified into three categories depending on different degrees of tissue injury and characteristics of DWI: (1) Edema-type: ten cases presented DWI high signals with different degree in local lesions. There were significant difference of ADC values between lesions and normal parts (t=7.515, P 2 WI heterogeneous high signals and T 1 WI low signals due to prominent hemorrhage. Conclusion: DWI of the spinal cord provided satisfactory images and was a useful method for visualizing the injury cord in the super-early stage, helping determine integrity and compression degree of spinal cord and detecting hemorrhage. (authors)

  2. Excretory MR urography using breathhold three-dimensional FISP: comparison with MR urography using HASTE technique

    Energy Technology Data Exchange (ETDEWEB)

    Song, Won Kue; Lee, Jeong Min; Jin, Kong Young; Hwang, Ho keung; Han, Young Min [Chonbuk Narional University Hospital, Chonju (Korea, Republic of); Ym, Seong Hee [Namwon Medical Center, Chonju (Korea, Republic of)

    2000-09-01

    To compare the usefulness of gadolinium-enhanced excretory MR urography using breath-hold three-dimensional fast imaging with steady state precession (3-D FISP) with conventional MR urography using the half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence in the evaluation of obstructive uropathy. Twenty-three patients in whom ultrasonography (US) and/or intravenous urography (IVU) revealed signs of urinary obstruction were enrolled in this study. Fifteen were men and eight were women, and their mean age was 54 (range, 21-80) years. All MR images were obtained using a 1.5T MR unit. MR urography using the HASTE technique (MRU) and gadolinium-enhanced excretory MR urography using the 3D-FISP technique were performed, and in all cases, reconstructions involved maximum intensity projection. For contrast-enhanced MR urography(CEMRU), images were obtained 3, 5, 20, and 30 minutes after the administration of intravenous contrast media, and for selected cases, additional images were obtained until 24 hours after contrast media injection. For qualitative analysis, two experienced radiologists compared CEMRU and MRU in terms of their diagnostic value as regards the level and cause of urinary obstruction, and morphologic accuracy. In addition, signal to noise ration(SNR) and contrast to noise ration (CNR) of the urinary tract at each anatomic level were quantitatively analysed. Quantitative analysis showed that in terms of SNR and CNR of the urinary tract at the level of the mid and distal ureter, CEMRU using 3-D FISP was better than MRU using HASTE (p less than 0.05). Qualitative analysis indicated that for the depiction of the whole length of normal ureter, and detection of the level of obstruction, anatomic anomalies and intrinsic tumors, 3-D FISP was superior to HASTE. There was, however, no difference between these two modalities in the diagnosis of ureteral stone and the degree of hydronephrosis. In addition, 3-D FISP was better than HASTE for the

  3. Excretory MR urography using breathhold three-dimensional FISP: comparison with MR urography using HASTE technique

    International Nuclear Information System (INIS)

    Song, Won Kue; Lee, Jeong Min; Jin, Kong Young; Hwang, Ho keung; Han, Young Min; Ym, Seong Hee

    2000-01-01

    To compare the usefulness of gadolinium-enhanced excretory MR urography using breath-hold three-dimensional fast imaging with steady state precession (3-D FISP) with conventional MR urography using the half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence in the evaluation of obstructive uropathy. Twenty-three patients in whom ultrasonography (US) and/or intravenous urography (IVU) revealed signs of urinary obstruction were enrolled in this study. Fifteen were men and eight were women, and their mean age was 54 (range, 21-80) years. All MR images were obtained using a 1.5T MR unit. MR urography using the HASTE technique (MRU) and gadolinium-enhanced excretory MR urography using the 3D-FISP technique were performed, and in all cases, reconstructions involved maximum intensity projection. For contrast-enhanced MR urography(CEMRU), images were obtained 3, 5, 20, and 30 minutes after the administration of intravenous contrast media, and for selected cases, additional images were obtained until 24 hours after contrast media injection. For qualitative analysis, two experienced radiologists compared CEMRU and MRU in terms of their diagnostic value as regards the level and cause of urinary obstruction, and morphologic accuracy. In addition, signal to noise ration(SNR) and contrast to noise ration (CNR) of the urinary tract at each anatomic level were quantitatively analysed. Quantitative analysis showed that in terms of SNR and CNR of the urinary tract at the level of the mid and distal ureter, CEMRU using 3-D FISP was better than MRU using HASTE (p less than 0.05). Qualitative analysis indicated that for the depiction of the whole length of normal ureter, and detection of the level of obstruction, anatomic anomalies and intrinsic tumors, 3-D FISP was superior to HASTE. There was, however, no difference between these two modalities in the diagnosis of ureteral stone and the degree of hydronephrosis. In addition, 3-D FISP was better than HASTE for the

  4. Worsening cholestasis and possible cefuroxime-induced liver injury following "successful" therapeutic endoscopic retrograde cholangiopancreatography for a distal common bile duct stone: a case report.

    Science.gov (United States)

    Niriella, Madunil Anuk; Kumarasena, Ravindu Sujeewa; Dassanayake, Anuradha Supun; Pathirana, Aloka; de Silva Hewavisenthi, Janaki; de Silva, Hithanadura Janaka

    2016-12-21

    Cefuroxime very rarely causes drug-induced liver injury. We present a case of a patient with paradoxical worsening of jaundice caused by cefuroxime-induced cholestasis following therapeutic endoscopic retrograde cholangiopancreatography for a distal common bile duct stone. A 51-year-old, previously healthy Sri Lankan man presented to our hospital with obstructive jaundice caused by a distal common bile duct stone. Endoscopic retrograde cholangiopancreatography with stone extraction, common bile duct clearance, and stenting failed to improve the cholestasis, with paradoxical worsening of his jaundice. A liver biopsy revealed features of drug-induced intrahepatic cholestasis. Although his case was complicated by an episode of cholangitis, the patient made a complete recovery in 4 months with supportive treatment and withdrawal of the offending drug. This case highlights a very rare drug-induced liver injury caused by cefuroxime as well as our approach to treating a patient with paradoxical worsening of jaundice after therapeutic endoscopic retrograde cholangiopancreatography.

  5. Tuberculosis 2: Pathophysiology and microbiology of pulmonary ...

    African Journals Online (AJOL)

    2005-08-01

    Aug 1, 2005 ... February 2013 Downloaded from www.southsudanmedicaljournal.com. MaIN arTIClES. 10. Tuberculosis 2: Pathophysiology and microbiology of pulmonary tuberculosis. Robert L. Serafino Wania MBBS, MrCP, MSc (Trop Med). Pathophysiology. Inhalation of Mycobacterium tuberculosis leads to one of.

  6. Diagnostic and Prevention Approach in Post Endoscopic Retrograde Cholangiopancreatography Pancreatitis

    Directory of Open Access Journals (Sweden)

    Stella Ilone

    2016-12-01

    Full Text Available Obstructive jaundice (icterus was an emergency situation in gastroenterology. Endoscopic retrograde cholangiopancreatography (ERCP was a nonsurgical approach to release obstruction, mostly in common bile duct. Nowadays, this procedure was become frequently used in daily practice, but several complications also emerging. One of the severe complication was Post-ERCP Pancreatitis (PEP. Since it has a high mortality and morbidity, and also reduce patient quality of life, several approaches have been developed to reduce its incidence. In general, approaches consist of patient identification, efficient procedure, until pharmacological agent prevention. Although there were still contradiction among these, careful approach should be considered for each patients for a better outcomes.

  7. Increased cholestatic enzymes in two patients with long-term history of ulcerative colitis: consider primary biliary cholangitis not always primary sclerosing cholangitis.

    Science.gov (United States)

    Polychronopoulou, Erietta; Lygoura, Vasiliki; Gatselis, Nikolaos K; Dalekos, George N

    2017-09-25

    Several hepatobiliary disorders have been reported in ulcerative colitis (UC) patients with primary sclerosing cholangitis (PSC) being the most specific. Primary biliary cholangitis (PBC), previously known as primary biliary cirrhosis, rarely occurs in UC. We present two PBC cases of 67 and 71 years who suffered from long-standing UC. Both patients were asymptomatic but they had increased cholestatic enzymes and high titres of antimitochondrial antibodies (AMA)-the laboratory hallmark of PBC. After careful exclusion of other causes of cholestasis by MRI/magnetic resonance cholangiopancreatography (MRCP), virological and microbiological investigations, a diagnosis of PBC associated with UC was established. The patients started ursodeoxycholic acid (13 mg/kg/day) with complete response. During follow-up, both patients remained asymptomatic with normal blood biochemistry. Although PSC is the most common hepatobiliary manifestation among patients with UC, physicians must keep also PBC in mind in those with unexplained cholestasis and repeatedly normal MRCP. In these cases, a reliable AMA testing can help for an accurate diagnosis. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Risk factors for pancreatic cancer and early diagnosis of pancreatic cancer

    International Nuclear Information System (INIS)

    Yamao, Kenji; Mizuno, Nobumasa; Sawaki, Akira; Shimizu, Yasuhiro; Chang, K.J.

    2008-01-01

    This paper describes the strategy for improving the poor prognosis of the pancreatic (P) cancer by its early imaging diagnosis followed by resection, based on recent findings on its high risk group. Epidemiological studies have revealed that patients with diabetes, chronic pancreatitis, intraductal papillary-mucious tumor, P cyst, familial history of P cancer, and hereditary P cancer syndrome are involved in the high risk group of P cancer. Imaging diagnosis with CT and/or endoscopic ultrasonography (EUS) followed by histological confirmation for resection can be a useful approach to improve the prognosis in those high risk, asymptomatic individuals with abnormal levels of P enzyme and tumor marker, and with US findings of P ductal dilation and cyst. The guideline 2006 for P cancer by Japan Pancreas Society shows the algorithm leading to the final diagnosis for the positive high risk group: firstly, CT and/or MRCP (MR cholangiopancreatography (CP)); or, in case of uncertainty, EUS and/or ERCP (E retrograde CP) and/or PET; and finally, cytological, histological diagnosis. The newer approach proposed recently for the group is: multi detector row (MD)-CT and EUS; then cytodiagnosis guided by ERCP and/or with fine needle aspiration by EUS, also a promising early diagnosis. As well, molecular biological approaches are supposedly useful for the future diagnosis. (R.T.)

  9. What is the most suitable MR signal index for quantitative evaluation of placental function using Half-Fourier acquisition single-shot turbo spin-echo compared with T2-relaxation time?

    Science.gov (United States)

    Kameyama, Kyoko Nakao; Kido, Aki; Himoto, Yuki; Moribata, Yusaku; Minamiguchi, Sachiko; Konishi, Ikuo; Togashi, Kaori

    2018-06-01

    Background Half-Fourier acquisition single-shot turbo spin-echo (HASTE) imaging is now widely used for placental and fetal imaging because of its rapidity and low sensitivity to fetal movement. If placental dysfunction is also predicted by quantitative value obtained from HASTE image, then it might be beneficial for evaluating placental wellbeing. Purpose To ascertain the most suitable magnetic resonance (MR) signal indexes reflecting placental function using HASTE imaging. Material and Methods This retrospective study included 37 consequent patients who had given informed consent to MR imaging (MRI) examinations. All had undergone MRI examinations between February 2014 and June 2015. First, the correlation between T2-relaxation time of normal placenta and gestational age (GA) was examined. Second, correlation between signal intensity ratios (SIRs) using HASTE imaging and placental T2-relaxation time were assessed. The SIRs were calculated using placental signal intensity (SI) relative to the SI of the amniotic fluid, fetal ocular globes, gastric fluid, bladder, maternal psoas major muscles, and abdominal subcutaneous adipose tissue. Results Among the 37 patients, the correlation between T2-relaxation time of the 25 normal placentas and GA showed a moderately strong correlation (Spearman rho = -0.447, P = 0.0250). The most significant correlation with placental T2-relaxation time was observed with the placental SIR relative to the maternal psoas major muscles (SIR pl./psoas muscle ) (Spearman rho = -0.531, P = 0.0007). Conclusion This study revealed that SIR pl./psoas muscle showed the best correlation to placental T2-relaxation time. Results show that SIR pl./psoas muscle might be optimal as a clinically available quantitative index of placental function.

  10. Generalised shot noise Cox processes

    DEFF Research Database (Denmark)

    Møller, Jesper; Torrisi, Giovanni Luca

    We introduce a new class of Cox cluster processes called generalised shot-noise processes (GSNCPs), which extends the definition of shot noise Cox processes (SNCPs) in two directions: the point process which drives the shot noise is not necessarily Poisson, and the kernel of the shot noise can...... be random. Thereby a very large class of models for aggregated or clustered point patterns is obtained. Due to the structure of GSNCPs, a number of useful results can be established. We focus first on deriving summary statistics for GSNCPs and next on how to make simulation for GSNCPs. Particularly, results...... for first and second order moment measures, reduced Palm distributions, the -function, simulation with or without edge effects, and conditional simulation of the intensity function driving a GSNCP are given. Our results are exemplified for special important cases of GSNCPs, and we discuss the relation...

  11. Computed tomography, ultrasonography, and endoscopic retrograde cholangiopancreatography in the diagnosis of pancreatic disease

    International Nuclear Information System (INIS)

    Foley, W.D.; Stewart, E.T.; Lawson, T.L.; Maher, L.; Unger, G.F.; Geenan, J.; Loguidice, J.

    1980-01-01

    A prospective study was performed comparing the sensitivity of computed tomography, ultrasonography, and endoscopic retrograde cholangiopancreatography (ERCP) in the diagnosis of pancreatic disease. Forty patients with suspected pancreatic carcinoma, acute recurrent or chronic pancreatitis, and/or jaundice were studied. CT was the most sensitive study in evaluation of pancreatitis. ERCP was most accurate in evaluation of pancreatic malignancy. Ultrasonography was the least sensitive method in detecting pancreatic disease and dilatation of the extrahepatic biliary ducts. (orig.) [de

  12. MR imaging assessment of cerebral vascular disease: A combination of angiographic and parenchymal techniques

    International Nuclear Information System (INIS)

    Masaryk, T.J.; Modic, M.T.; Ross, J.S.; Ruggieri, P.; Laub, G.; Haacke, E.M.

    1988-01-01

    This study tested the accuracy and clinical utility of a three-dimensional MR angiographic technique of the cervical carotids in combination with a routine spin-echo examination of the brain as a screening examination for cerebrovascular disease in 23 patients. The technique used a fast low-angle shot sequence with a reduced echo time and voxel size, gradient refocusing, and time of flight effects to minimize signal loss secondary to phase dispersion and maximize vessel contrast. Subsequent multiplanar three-dimensional reconstructions were obtained at 5 0 increments about the z-axis via ray-tracing linear thresholding algorithms. Examinations were compared with IV/IA-digital subtraction angiography or Doppler US as the objective of accuracy. Results of this ongoing study indicate that an MR angiographic screening examination can be coupled with routine brain MR imaging with only a 10-14 minute extension of examination time, providing both a vascular and a parenchymal evaluation

  13. Orchestrating Shots for the National Ignition Facility (NIF)

    International Nuclear Information System (INIS)

    Mathisen, D G; Bettenhausen, R C; Beeler, R G; Bowers, G A; Carey, R W; Casavant, D D; Cline, B D; Demaret, R D; Domyancic, D M; Elko, S D; Fisher, J M; Krammen, J E; Lagin, L J; Ludwigsen, A P; Patterson, R W; Sanchez, R J; Stout, E A

    2005-01-01

    The National Ignition Facility (NIF), currently under construction at the Lawrence Livermore National Laboratory, is a stadium-sized facility containing a 192-beam, 1.8 Megajoule, 500-Terawatt, ultra-violet laser system together with a 10-meter diameter target chamber with room for nearly 100 experimental diagnostics. When completed, NIF will be the world's largest and most energetic laser experimental system, providing an international center to study inertial confinement fusion and physics of matter at extreme densities and pressures. The NIF is operated by the Integrated Computer Control System (ICCS), which is a layered architecture of over 700 lower-level front-end processors attached to nearly 60,000 control points and coordinated by higher-level supervisory subsystems in the main control room. A shot automation framework has been developed and deployed during the past year to orchestrate and automate shots performed at the NIF using the ICCS. The Shot Automation framework is designed to automate 4-8 hour shot sequences, that includes deriving shot goals from an experiment definition, set up of the laser and diagnostics, automatic alignment of laser beams, and a countdown to charge and fire the lasers. These sequences consist of set of preparatory verification shots, leading to amplified system shots followed by post-shot analysis and archiving. The framework provides for a flexible, model-based work-flow execution, driven by scripted automation called macro steps. The shot director software is the orchestrating component of a very flexible automation layer which allows us to define, coordinate and reuse simpler automation sequences. This software provides a restricted set of shot life cycle state transitions to 26 collaboration supervisors that automate 8-laser beams (bundle) and a common set of shared resources. Each collaboration supervisor commands approximately 10 subsystem shot supervisors that perform automated control and status verification

  14. Graduates of different UK medical schools show substantial differences in performance on MRCP(UK Part 1, Part 2 and PACES examinations

    Directory of Open Access Journals (Sweden)

    Mollon Jennifer

    2008-02-01

    Full Text Available Abstract Background The UK General Medical Council has emphasized the lack of evidence on whether graduates from different UK medical schools perform differently in their clinical careers. Here we assess the performance of UK graduates who have taken MRCP(UK Part 1 and Part 2, which are multiple-choice assessments, and PACES, an assessment using real and simulated patients of clinical examination skills and communication skills, and we explore the reasons for the differences between medical schools. Method We perform a retrospective analysis of the performance of 5827 doctors graduating in UK medical schools taking the Part 1, Part 2 or PACES for the first time between 2003/2 and 2005/3, and 22453 candidates taking Part 1 from 1989/1 to 2005/3. Results Graduates of UK medical schools performed differently in the MRCP(UK examination between 2003/2 and 2005/3. Part 1 and 2 performance of Oxford, Cambridge and Newcastle-upon-Tyne graduates was significantly better than average, and the performance of Liverpool, Dundee, Belfast and Aberdeen graduates was significantly worse than average. In the PACES (clinical examination, Oxford graduates performed significantly above average, and Dundee, Liverpool and London graduates significantly below average. About 60% of medical school variance was explained by differences in pre-admission qualifications, although the remaining variance was still significant, with graduates from Leicester, Oxford, Birmingham, Newcastle-upon-Tyne and London overperforming at Part 1, and graduates from Southampton, Dundee, Aberdeen, Liverpool and Belfast underperforming relative to pre-admission qualifications. The ranking of schools at Part 1 in 2003/2 to 2005/3 correlated 0.723, 0.654, 0.618 and 0.493 with performance in 1999–2001, 1996–1998, 1993–1995 and 1989–1992, respectively. Conclusion Candidates from different UK medical schools perform differently in all three parts of the MRCP(UK examination, with the

  15. Gadolinium-enhanced turbo FLASH MR imaging of renal perfusion and excretion

    International Nuclear Information System (INIS)

    Watanabe, A.; Teresi, L.M.; Herbst, M.; O'Sullivan, R.M.; Lee, R.; Smith, C.; Renner, J.; Rappaport, A.; Bradley, W.G. Jr.

    1990-01-01

    This paper describes a novel approach to MR imaging of renal perfusion and excretion using gadolinium-enhanced, T1-weighted TURBP, fast low-angle shot (FLASH) imaging. Five normal volunteers and four patients were studied on a 1.5-T imaging system. Time-intensity curves of the appearance of gadolinium in each kidney and the bladder were then generated. In normal volunteers, marked first-pass enhancement of renal cortex followed by renal pyramids and collecting systems could be demonstrated on the first-pass gadolinium images. Delayed images showed hyperintense gadolinium within the bladder

  16. Readout-segmented echo-planar imaging improves the image quality of diffusion-weighted MR imaging in rectal cancer: Comparison with single-shot echo-planar diffusion-weighted sequences

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Chun-chao; Liu, Xi; Peng, Wan-lin; Li, Lei; Zhang, Jin-ge [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Meng, Wen-jian; Deng, Xiang-bing [Department of Gastrointestinal Surgery, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Zuo, Pan-li [Siemens Healthcare, MR Collaborations NE Asia, 100010, Beijing (China); Li, Zhen-lin, E-mail: lzlcd01@126.com [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China)

    2016-10-15

    Purpose: To determine whether readout-segmented echo-planar imaging (rs-EPI) diffusion-weighted imaging (DWI) can improve the image quality in patients with rectal cancer compared with single-shot echo-planar imaging (ss-EPI) DWI using 3.0 T magnetic resonance (MR) imaging. Materials and methods: This study was approved by the Institutional Review Board, and informed consent was obtained from all patients. Seventy-one patients with rectal cancer were enrolled in this study. For all patients, both rs-EPI and ss-EPI DWI were performed using a 3T MR scanner. Two radiologists independently assessed the overall image quality, lesion conspicuity, geometric distortion and distinction of anatomical structures. The signal-to-noise ratio (SNR), lesion contrast, contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) were also measured. Comparisons of the quantitative and qualitative parameters between the two sequences were performed using the paired t-test and the Wilcoxon signed rank test. Results: The scores of overall image quality, lesion conspicuity, geometric distortion and distinction of anatomical structures of rs-EPI were all significantly higher than those of ss-EPI (all p < 0.05). The SNR and CNR were higher in rs-EPI than those in ss-EPI (all p < 0.05). There was no significant difference between ss-EPI and rs-EPI with regard to ROI size and mean ADCs of the tumour (p = 0.574 and p = 0.479, respectively), but the mean ADC of the normal tissue was higher in rs-EPI than in ss-EPI (1.73 ± 0.30 × 10{sup −3} mm{sup 2}/s vs. 1.60 ± 0.31 × 10{sup −3} mm{sup 2}/s, p = 0.001). Conclusions: DW imaging based on readout-segmented echo-planar imaging is a clinically useful technique to improve the image quality for the purpose of evaluating lesions in patients with rectal tumours.

  17. Duodenal perforation: after endoscopic retrograde cholangiopancreatography: when to operate?

    International Nuclear Information System (INIS)

    Garcia Navarrete, Aldhem Francisco

    2014-01-01

    The mainly surgical management of duodenal perforation as the iatrogenicity of endoscopic retrograde cholangiopancreatography (ERCP) is defined and protocolized through the exhaustive review of the most conclusive literature available on the subject. Bibliography on the management of post-ERCP duodenal perforation is reviewed in scientific databases, textbooks, publications of medical journals, MD Consult and Medline. A total of 60 bibliographical citations were reviewed; succeeding in defining the protocol on the management of this type of complications, thanks to the appropriate selection of the most conclusive citations and the greatest consensus on the subject. A total of 60 bibliographical citations were reviewed; succeeding in defining the protocol on the management of this type of complications, based on the appropriate selection of the most conclusive citations and the greatest consensus on the subject [es

  18. First-pass myocardial perfusion MR imaging with gadolinium-enhanced turbo FLASH

    International Nuclear Information System (INIS)

    Teresi, L.M.; Smith, C.; Messenger, J.; Watanabe, A.; Herbst, M.; O'Sullivan, R.M.; Lee, R.; Remer, J.; Rappaport, A.; Bradley, W.G.

    1990-01-01

    This paper determines the efficacy of MR first-pass myocardial perfusion imaging using gadolinium-enhanced Turbo--fast low-angle shot (FLASH) ultrafast imaging combined with MR systolic wall thickening data for the determination of myocardial viability. Five normal volunteers and five patients with remote myocardial infarction were studied on a 1.5-T imaging system (Siemans, Ehrlangen, NJ). Turbo-FLASH imaging utilized a 180 degrees inversion pulse followed by a rapid gradient-echo sequence (TI 400 msec, TE2 msec, TR 4.9 msec, FA 8 degrees) with a complete 64 x 64 matrix image (300 mm FOV) being acquired in 300 msec. First-pass myocardial perfusion imaging was performed in the short-axis and long-axis oblique projections with a concantenated series of Turbo-FLASH images triggered to end-systole acquired immediately before and during a rapid bolus injection of 5cc gadolinium-DTPA

  19. Catastrophe Insurance Modeled by Shot-Noise Processes

    Directory of Open Access Journals (Sweden)

    Thorsten Schmidt

    2014-02-01

    Full Text Available Shot-noise processes generalize compound Poisson processes in the following way: a jump (the shot is followed by a decline (noise. This constitutes a useful model for insurance claims in many circumstances; claims due to natural disasters or self-exciting processes exhibit similar features. We give a general account of shot-noise processes with time-inhomogeneous drivers inspired by recent results in credit risk. Moreover, we derive a number of useful results for modeling and pricing with shot-noise processes. Besides this, we obtain some highly tractable examples and constitute a useful modeling tool for dynamic claims processes. The results can in particular be used for pricing Catastrophe Bonds (CAT bonds, a traded risk-linked security. Additionally, current results regarding the estimation of shot-noise processes are reviewed.

  20. A review on the basketball jump shot.

    Science.gov (United States)

    Okazaki, Victor H A; Rodacki, André L F; Satern, Miriam N

    2015-06-01

    The ability to shoot an effective jump shot in the sport of basketball is critical to a player's success. In an attempt to better understand the aspects related to expert performance, researchers have investigated successful free throws and jump shots of various basketball players and identified movement variables that contribute to their success. The purpose of this study was to complete a systematic review of the scientific literature on the basketball free throw and jump shot for the purpose of revealing the critical components of shooting that coaches, teachers, and players should focus on when teaching, learning, practising, and performing a jump shot. The results of this review are presented in three sections: (a) variables that affect ball trajectory, (b) phases of the jump shot, and (c) additional variables that influence shooting.

  1. Calculation of T2 relaxation time from ultrafast single shot sequences for differentiation of liver tumors. Comparison of echo-planar, HASTE, and spin-echo sequences

    International Nuclear Information System (INIS)

    Abe, Yasuko; Yamashita, Yasuyuki; Tang, Yi; Namimoto, Tomohiro; Takahashi, Mutsumasa

    2000-01-01

    The purpose of this study was to evaluate the accuracy of T2 calculation from single shot imaging sequences such as echo-planar imaging (EPI) and half-Fourier single shot turbo spin-echo (HASTE) imaging. For the phantom study, we prepared vials containing different concentrations of agarose, copper sulfate, and nickel chloride. The temperature of the phantom was kept at 22 deg C. MR images were obtained with a 1.5-Tesla superconductive magnet. Spin-echo (SE)-type EPI and HASTE sequences with different TEs were obtained for T2 calculation, and the T2 values were compared with those obtained from the Carr-Purcell-Meiborm-Gill (CPMG) sequence. The clinical study group consisted of 30 consecutive patients referred for MR imaging to characterize focal liver lesions. A total of 40 focal liver lesions were evaluated, including 25 primary or metastatic solid masses and 15 non-solid lesions. Single shot SE-type EPI and HASTE were both performed with TEs of 64 and 90 msec. In the phantom study, the T2 values obtained from both single shot sequences showed significant correlations with those from the CPMG sequence (T2 on EPI vs. T2 on CPMG: r=0.98, p<0.01; T2 on HASTE vs. T2 on CPMG: r=0.99, p<0.01). In the clinical study, mean T2 values for liver calculated from EPI (42 msec) were significantly shorter than those calculated from the HASTE sequence (58 msec) (p<0.001). Mean T2 values for solid tumors were 95 msec with HASTE and 72 msec with EPI, and mean T2 values for non-solid lesions were 128 msec with HASTE and 159 msec with EPI. Although mean T2 values between solid and non-solid lesions were significantly different for both EPI and HASTE sequences (p=0.01 for HASTE, p<0.001 for EPI), the overlap of solid and non-solid lesions was less frequent in EPI than in HASTE. With single shot sequences, it is possible to obtain the T2 values that show excellent correlation with the CPMG sequence. Although both HASTE and EPI are useful to calculate T2 values, EPI appears to be more

  2. Research of shot noise based on realistic nano-MOSFETs

    Directory of Open Access Journals (Sweden)

    Xiaofei Jia

    2017-05-01

    Full Text Available Experimental measurements and simulation results have shown that the dominant noise source of current noise changes from thermal noise to shot noise with scaling of MOSFET, and shot noise were suppressed by Fermi and Coulomb interactions. In this paper, Shot noise test system is established, and experimental results proved that shot noise were suppressed, and the expressions of shot noise in realistic nano-MOSFETs are derived with considering Fermi effect, Coulomb interaction and the combination of the both co-existence, respectively. On this basis, the variation of shot noise with voltage, temperature and source-drain doping were researched. The results we obtained are consistent with those from experiments and the theoretically explanation is given. At the same time, the shot noise test system is suitable for traditional nanoscale electronic components; the shot noise model is suitable for nanoscale MOSFET.

  3. Investigation of kinematics of knuckling shot in soccer

    Science.gov (United States)

    Asai, T.; Hong, S.

    2017-02-01

    In this study, we use four high-speed video cameras to investigate the swing characteristics of the kicking leg while delivering the knuckling shot in soccer. We attempt to elucidate the impact process of the kicking foot at the instant of its impact with the ball and the technical mechanisms of the knuckling shot via comparison of its curved motion with that of the straight and curved shots. Two high-speed cameras (Fastcam, Photron Inc., Tokyo, Japan; 1000 fps, 1024 × 1024 pixels) are set up 2 m away from the site of impact with a line of sight perpendicular to the kicking-leg side. In addition, two semi-high-speed cameras (EX-F1, Casio Computer Co., Ltd., Tokyo, Japan; 300 fps; 720 × 480 pixels) are positioned, one at the rear and the other on the kicking-leg side, to capture the kicking motion. We observe that the ankle joint at impact in the knuckling shot flexes in an approximate L-shape in a manner similar to the joint flexing for the curve shot. The hip's external rotation torque in the knuckling shot is greater than those of other shots, which suggests the tendency of the kicker to push the heel forward and impact with the inside of the foot. The angle of attack in the knuckling shot is smaller than that in other shots, and we speculate that this small attack angle is a factor in soccer kicks which generate shots with smaller rotational frequencies of the ball.

  4. Diagnostic value of MRI for hepatic hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Wang Zhen; Zuo Yujiang; Sun Lihui; Zhou Jian; Shen Bingqi

    2010-01-01

    Objective: To investigate the value of MRI in the diagnosis of hepatic hilar cholangiocarcinoma. Methods: Sixty-four patients with hepatic hilar cholangiocarcinomas confirmed by surgery or pathology underwent MRI using a 1.5-T superconductive MR system including conventional unenhanced MRI, MRCP and dynamic contrast-enhanced MRI with Gd-DTPA. Results: Dilatation of the intrahepatic biliary tree with narrowing, occlusion or filling defects in the hepatic hilar bile ducts was noted in all 64 cases. Unenhanced MR[ showed T 1 - and T 2 -hyperintense hilar masses in 42 patients and was normal in the remaining 22 patients. The hilar masses demonstrated slow, progressive and delayed enhancement patterns. There was enhancement of the thickened bile duct wall with luminal narrowing in the 22 patients without hilar masses. Conclusion: The characteristic MRI findings of enhancing hepatic hilar mass and bile duct wall thickening together with MRCP are valuable for diagnosing hepatic hilar cholangiocarcinomas. (authors)

  5. Ultrafast MR Imaging in Pediatric Neuroradiology

    International Nuclear Information System (INIS)

    Singh, R.K.; Smith, J.T.; Wilkinson, I.D.; Griffiths, P.D.

    2003-01-01

    Purpose: To compare the diagnostic information obtained from ultrafast MR imaging with standard MR imaging techniques in pediatric neuroradiology. The goal was to judge whether ultrafast methods can be used to replace standard methods and reduce the need for sedation or general anesthesia as a result of the considerably shorter scan times. Material and Methods: Our prospective study involved 125 patients. Routine clinical imaging was performed along with two ultrafast methods. Single shot fast spin echo (SSFSE) was used to give T2-weighted images and an echo planar imaging (EPI) sequence to provide a T1-weighted images. The ultrafast images were presented to an experienced neuro radiologist who was also given the information present on the initial referral card. These reports based on the ultrafast images were then compared with the formal radiologic report made solely on the basis of the standard imaging. Results: The overall sensitivity and specificity for ultrafast imaging when compared to the reference standard were 78% and 98% with positive and negative predictive values of 98% and 76%. Pathologies characterized by small areas of subtle T2 prolongation were difficult or impossible to see on the ultrafast images but otherwise they provided reliable information. Conclusions: This paper demonstrates that ultrafast MR imaging can diagnose many pediatric intracranial abnormalities as well as standard methods. Anatomic resolution limits its capacity to define subtle developmental anomalies and contrast resolution limitations of the ultrafast methods reduce the detection of pathology characterized by subtle T2 prolongation

  6. Multishot versus single-shot pulse sequences in very high field fMRI: a comparison using retinotopic mapping.

    Directory of Open Access Journals (Sweden)

    Jascha D Swisher

    Full Text Available High-resolution functional MRI is a leading application for very high field (7 Tesla human MR imaging. Though higher field strengths promise improvements in signal-to-noise ratios (SNR and BOLD contrast relative to fMRI at 3 Tesla, these benefits may be partially offset by accompanying increases in geometric distortion and other off-resonance effects. Such effects may be especially pronounced with the single-shot EPI pulse sequences typically used for fMRI at standard field strengths. As an alternative, one might consider multishot pulse sequences, which may lead to somewhat lower temporal SNR than standard EPI, but which are also often substantially less susceptible to off-resonance effects. Here we consider retinotopic mapping of human visual cortex as a practical test case by which to compare examples of these sequence types for high-resolution fMRI at 7 Tesla. We performed polar angle retinotopic mapping at each of 3 isotropic resolutions (2.0, 1.7, and 1.1 mm using both accelerated single-shot 2D EPI and accelerated multishot 3D gradient-echo pulse sequences. We found that single-shot EPI indeed led to greater temporal SNR and contrast-to-noise ratios (CNR than the multishot sequences. However, additional distortion correction in postprocessing was required in order to fully realize these advantages, particularly at higher resolutions. The retinotopic maps produced by both sequence types were qualitatively comparable, and showed equivalent test/retest reliability. Thus, when surface-based analyses are planned, or in other circumstances where geometric distortion is of particular concern, multishot pulse sequences could provide a viable alternative to single-shot EPI.

  7. Fetal cleft lip with and without cleft palate: Comparison between MR imaging and US for prenatal diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Wang Guangbin, E-mail: wgb7932596@hotmail.com [Shandong Medical Imaging Research Institute, 324 Jingwu Road, Jinan, 250021 (China); Shan Ruiqin [Jinan Maternity and Child Care Hospital, Jinan (China); Zhao Lianxin; Zhu Xiangyu; Zhang Xinjuan [Shandong Medical Imaging Research Institute, 324 Jingwu Road, Jinan, 250021 (China)

    2011-09-15

    Objective: To describe the magnetic resonance (MR) imaging findings of fetal CL/CP and evaluate its diagnostic value. Methods and materials: Twelve fetuses with CL/CP diagnosed by transabdominal US underwent MR imaging within 2 days of US. Half-Fourier acquisition single-shot turbo spin echo (HASTE) sequence on T2-weighted images was performed on sagittal, coronal, and axial planes anatomic to the fetuses during maternal breath holding. US and MR imaging findings were compared with final diagnoses obtained from post-natal physical examination or fetal autopsy. Results: Final diagnoses confirmed incomplete midline cleft lip (n = 1), unilateral cleft lip and palate (n = 7), bilateral cleft lip and palate (n = 1), midline cleft lip and palate (n = 3). US and MR imaging diagnosed all 12 fetuses with cleft lip and the laterality. 5 (45.5%) of 11 cleft palates were identified with US, 2 of 7 fetuses with unilateral cleft palate, 2 of 3 fetuses with midline cleft palate, and one fetus with bilateral cleft palate. On MR imaging, 10 (91%) of 11 cleft palates were correctly detected. One fetus with unilateral cleft palate was not detected. No false-positives occurred. Conclusion: MR imaging is valuable for diagnosis of fetal CL/CP. It can demonstrate additional findings and provide more information compared with US.

  8. Fetal cleft lip with and without cleft palate: Comparison between MR imaging and US for prenatal diagnosis

    International Nuclear Information System (INIS)

    Wang Guangbin; Shan Ruiqin; Zhao Lianxin; Zhu Xiangyu; Zhang Xinjuan

    2011-01-01

    Objective: To describe the magnetic resonance (MR) imaging findings of fetal CL/CP and evaluate its diagnostic value. Methods and materials: Twelve fetuses with CL/CP diagnosed by transabdominal US underwent MR imaging within 2 days of US. Half-Fourier acquisition single-shot turbo spin echo (HASTE) sequence on T2-weighted images was performed on sagittal, coronal, and axial planes anatomic to the fetuses during maternal breath holding. US and MR imaging findings were compared with final diagnoses obtained from post-natal physical examination or fetal autopsy. Results: Final diagnoses confirmed incomplete midline cleft lip (n = 1), unilateral cleft lip and palate (n = 7), bilateral cleft lip and palate (n = 1), midline cleft lip and palate (n = 3). US and MR imaging diagnosed all 12 fetuses with cleft lip and the laterality. 5 (45.5%) of 11 cleft palates were identified with US, 2 of 7 fetuses with unilateral cleft palate, 2 of 3 fetuses with midline cleft palate, and one fetus with bilateral cleft palate. On MR imaging, 10 (91%) of 11 cleft palates were correctly detected. One fetus with unilateral cleft palate was not detected. No false-positives occurred. Conclusion: MR imaging is valuable for diagnosis of fetal CL/CP. It can demonstrate additional findings and provide more information compared with US.

  9. Antioxidant drugs to prevent post-endoscopic retrograde cholangiopancreatography pancreatitis: What does evidence suggest?

    Science.gov (United States)

    Fuentes-Orozco, Clotilde; Dávalos-Cobián, Carlos; García-Correa, Jesús; Ambriz-González, Gabriela; Macías-Amezcua, Michel Dassaejv; García-Rentería, Jesús; Rendón-Félix, Jorge; Chávez-Tostado, Mariana; Cuesta-Márquez, Lizbeth Araceli; Alvarez-Villaseñor, Andrea Socorro; Cortés-Flores, Ana Olivia; González-Ojeda, Alejandro

    2015-06-07

    To determine whether or not the use of antioxidant supplementation aids in the prevention of post- endoscopic retrograde cholangiopancreatography pancreatitis. A systematic review of randomized controlled trials (RCTs) was made to evaluate the preventive effect of prophylactic antioxidant supplementation in post-endoscopic retrograde cholangiopancreatography pancreatitis (PEP). The inclusion criteria included: acute post-endoscopic retrograde cholangiopancreatography pancreatitis in adults; randomized clinical trials with the use of any antioxidant as an intervention compared with placebo, to reduce PEP. The outcome measure was the incidence and severity of PEP. Twelve RCTs involving 3110 patients since 1999 were included. The antioxidants used were selenite, β-carotene, and pentoxifylline (each one in one trial), N-acetylcysteine (NAC) in three trials, and allopurinol in six trials. The group of patients treated with NAC received different doses; either oral or intravenous, and allopurinol-treated patients received five different oral doses in two different administration periods. The results are expressed with raw numbers, proportions, as well as mean and standard deviations. The incidence of pancreatitis between groups was analyzed with Pearson's χ(2) test or Fisher's exact test (F). The main outcome is expressed as relative risks and 95%CI. The incidence of pancreatitis in all antioxidant treatment groups was 8.6%, whereas it was 9.7% in the control group. The antioxidants used were selenite, β-carotene, and pentoxifylline (each one in one trial), NAC in three trials, and allopurinol in six trials. In allopurinol trials, three different dosifications were used; two trials reported a low dosage (of less than 400 mg), two trials reported a moderate dose (600 mg) and the remaining two employed higher doses (more than 900 mg). Supplementation was not associated with a significant reduction in the incidence of PEP [relative risk (RR) = 0.93; 95%CI: 0.82-1.06; P

  10. Analysis of shot-to-shot variability in post-disruption runaway electron currents for diverted DIII-D discharges

    International Nuclear Information System (INIS)

    Izzo, V A; Humphreys, D A; Kornbluth, M

    2012-01-01

    In DIII-D experiments, rapid termination by Ar-pellet injection sometimes produces a post-termination runaway electron (RE) current plateau, but this effect is highly non-reproducible on a shot-to-shot basis, particularly for diverted target plasmas. A set of DIII-D discharges is analyzed with two MHD codes to understand the relationship between the current profile of the target plasma and the amplitude of the RE current plateau. Using the linear stability code GATO, a correlation between the radial profile of the unstable n = 1 mode just after Ar-pellet injection and the observed appearance of an RE plateau is identified. Nonlinear NIMROD simulations with RE test-particle calculations directly predict RE confinement times during the disruption. With one exception, NIMROD predicts better RE confinement for shots in which higher RE currents were observed in DIII-D. But, the variation in confinement is primarily connected to the saturated n = 1 mode amplitude and not its radial profile. Still, both sets of analyses support the hypothesis that RE deconfinement by MHD fluctuations is a major factor in the shot-to-shot variability of RE plateaus, though additional factors such as seed current amplitude cannot be ruled out. (paper)

  11. Usefulness of MR angiography in renal tumor

    Energy Technology Data Exchange (ETDEWEB)

    Oka, Toshitsugu; Morimoto, Kouji; Nishimura, Kenji; Tsujimura, Akira; Yasunaga, Yutaka; Matsumiya, Kiyomi; Takaha, Minato (Osaka National Hospital (Japan))

    1992-11-01

    MR angiography using a gradient-echo, pulse sequence FLASH (fast, low-angle shot) method during breath-hold with a MAGNETOM H-15 scanner (1.5 Tesla; Siemens Medical System) was performed on 27 patients with renal tumor at our clinic between Feburary 20, 1990 and September 30, 1991 and we studied to evaluate its usefulness. Of these 27 patients, 22 patients including one patient under hemodialysis treatment had renal cell carcinoma and one patient had oncocytoma pathologically proven from the excised specimens. The remaining four patients including two patients associated with inferior vena cava tumor thrombus were clinically diagnosed as renal cell carcinoma based on the result of imaging examinations such as excretory urography, ultrasonography, computed tomography and conventional angiography. However, they could not be operated on because their tumors were too advanced. By reconstruction of the data of consecutive coronal scans of the abdominal blood vessels such as the abdominal aorta, inferior vena cava and renal arteries and veins simultaneously without any intravenous contrast materials. Our present study revealed that MR angiography has some advantages, especially with regard to preoperative angiographic information about the abdomen of patients with renal tumor. That is, MR angiography can delineate many kinds of arteries and veins of the abdomen simultaneously and in a broader range, as well as it can be performed on the patients with hypersensitivity to iodinate contrast materials or renal insufficiency in a usual fashion. Furthermore, our present study suggested that the MR angiography is useful for assessing the presence and extent of inferior vena caval tumor thrombus of renal cell carcinoma and for clearly distinguishing tumor lesion and the surrounding normal renal parenchyma in the patients with renal tumor. (author).

  12. Usefulness of MR angiography in renal tumor

    International Nuclear Information System (INIS)

    Oka, Toshitsugu; Morimoto, Kouji; Nishimura, Kenji; Tsujimura, Akira; Yasunaga, Yutaka; Matsumiya, Kiyomi; Takaha, Minato

    1992-01-01

    MR angiography using a gradient-echo, pulse sequence FLASH (fast, low-angle shot) method during breath-hold with a 'MAGNETOM H-15' scanner (1.5 Tesla; Siemens Medical System) was performed on 27 patients with renal tumor at our clinic between Feburary 20, 1990 and September 30, 1991 and we studied to evaluate its usefulness. Of these 27 patients, 22 patients including one patient under hemodialysis treatment had renal cell carcinoma and one patient had oncocytoma pathologically proven from the excised specimens. The remaining four patients including two patients associated with inferior vena cava tumor thrombus were clinically diagnosed as renal cell carcinoma based on the result of imaging examinations such as excretory urography, ultrasonography, computed tomography and conventional angiography. However, they could not be operated on because their tumors were too advanced. By reconstruction of the data of consecutive coronal scans of the abdominal blood vessels such as the abdominal aorta, inferior vena cava and renal arteries and veins simultaneously without any intravenous contrast materials. Our present study revealed that MR angiography has some advantages, especially with regard to preoperative angiographic information about the abdomen of patients with renal tumor. That is, MR angiography can delineate many kinds of arteries and veins of the abdomen simultaneously and in a broader range, as well as it can be performed on the patients with hypersensitivity to iodinate contrast materials or renal insufficiency in a usual fashion. Furthermore, our present study suggested that the MR angiography is useful for assessing the presence and extent of inferior vena caval tumor thrombus of renal cell carcinoma and for clearly distinguishing tumor lesion and the surrounding normal renal parenchyma in the patients with renal tumor. (author)

  13. Osseointegration improvement by shot peening in titanium dental implants

    International Nuclear Information System (INIS)

    Aparicio, C.; Gil, F.J.; Planell, J.A.; Padros, A.; Peraire, C.

    1998-01-01

    In order to optimize the implant-bone fixation, different shot peening treatments with different shot particles (TiO 2 , Al 2 O 3 ; SiC) have been made. The influence that each type of shot particle has in the bone colonization on the different treatment surfaces has been determined by means of osteoblast-like cells culture. Commercially pure titanium discs have been shot peened. Their qualitative and quantitative surface roughness have been characterized; as well as their surface contamination caused by the shot particles. Particle size has also been determined, before and after the treatment, in order to evaluate their breaking averages. Finally, a TiO 2 shot particles manufacture process by sintering has been developed. The manufacture has been necessary since this type of shot particles are not available in the market with the adequate size. (Author) 10 refs

  14. Concrete Cleaning, Inc. centrifugal shot blaster: Baseline report; Summary

    International Nuclear Information System (INIS)

    1997-01-01

    The centrifugal shot blaster is an electronically operated shot-blast machine that removes layer of concrete of varying depths. Hardened steel shot propelled at a high rate of speed abrades the surface of the concrete. The depth of material removed is determined by the rate of speed the machine is traveling and the volume of shot being fired into the blast chamber. The steel shot is reused until it is pulverized to dust, which is deposited in the waste container with the concrete being removed. Debris is continually vacuumed by a large dust collection system attached to the shot blaster. The safety and health evaluation during the human factors assessment focused on two main areas: noise and dust

  15. Correlation between High Resolution Dynamic MR Features and Prognostic Factors in Breast Cancer

    International Nuclear Information System (INIS)

    Lee, Shin Ho; Cho, Nariya; Kim, Seung Ja; Cho, Kyung Soo; Ko, Eun Sook; Moon, Woo Kyung; Cha, Joo Hee

    2008-01-01

    To correlate high resolution dynamic MR features with prognostic factors in breast cancer. One hundred and ninety-four women with invasive ductal carcinomas underwent dynamic MR imaging using T1-weighted three dimensional fast low-angle shot (3D-FLASH) sequence within two weeks prior to surgery. Morphological and kinetic MR features were determined based on the breast imaging and reporting data system (BI-RADS) MR imaging lexicon. Histological specimens were analyzed for tumor size, axillary lymph node status, histological grade, expression of estrogen receptor (ER), expression of progesterone receptor (PR), and expression of p53, c-erbB-2, and Ki-67. Correlations between the MR features and prognostic factors were determined using the Pearson x 2 test, linear-by-linear association, and logistic regression analysis. By multivariate analysis, a spiculated margin was a significant, independent predictor of a lower histological grade (p < 0.001), and lower expression of Ki-67 (p = 0.007). Rim enhancement was significant, independent predictor of a higher histological grade (p < 0.001), negative expression of ER (p 0.001), negative expression of PR (p < 0.001) and a larger tumor size (p = 0.006). A washout curve may predict a higher level of Ki-67 (p = 0.05). Most of the parameters of the initial enhancement phase cannot predict the status of the prognostic factors. Only the enhancement ratio may predict a larger tumor size (p 0.05). Of the BI-RADS-MR features, a spiculated margin may predict favorable prognosis, whereas rim enhancement or washout may predict unfavorable prognosis of breast cancer

  16. Research advances in the prevention and treatment of pancreatitis after endoscopic retrograde cholangiopancreatography

    Directory of Open Access Journals (Sweden)

    ZHANG Weifeng

    2018-03-01

    Full Text Available Endoscopic retrograde cholangiopancreatography (ERCP is an important technique for the diagnosis and treatment of biliary and pancreatic diseases and post-ERCP pancreatitis (PEP is the most common complication of ERCP. Since the birth of ERCP, the prevention and treatment of PEP has become the focus of international research. In recent years, much progress has been made in the aspects of risk factors, pharmacological prevention, and prophylactic stent implantation in the pancreatic duct. Since these research findings are not consistent, further clinical studies are needed to demonstrate such findings.

  17. Influence of Running on Pistol Shot Hit Patterns.

    Science.gov (United States)

    Kerkhoff, Wim; Bolck, Annabel; Mattijssen, Erwin J A T

    2016-01-01

    In shooting scene reconstructions, risk assessment of the situation can be important for the legal system. Shooting accuracy and precision, and thus risk assessment, might be correlated with the shooter's physical movement and experience. The hit patterns of inexperienced and experienced shooters, while shooting stationary (10 shots) and in running motion (10 shots) with a semi-automatic pistol, were compared visually (with confidence ellipses) and statistically. The results show a significant difference in precision (circumference of the hit patterns) between stationary shots and shots fired in motion for both inexperienced and experienced shooters. The decrease in precision for all shooters was significantly larger in the y-direction than in the x-direction. The precision of the experienced shooters is overall better than that of the inexperienced shooters. No significant change in accuracy (shift in the hit pattern center) between stationary shots and shots fired in motion can be seen for all shooters. © 2015 American Academy of Forensic Sciences.

  18. A study on MR images of the articular cartilage in medial-type osteoarthritis of the knee

    International Nuclear Information System (INIS)

    Miyazaki, Hiroyuki; Ishii, Yoshiaki; Hayashi, Mitsutoshi; Kotani, Akihiro

    2001-01-01

    Changes in the articular cartilage of 88 knees of 73 cases (age range 40-78) diagnosed clinically and radiologically as OA (osteoarthritis) were studied by obtaining fat-suppressed MR images of the knee. On 27 knees out of the 88, moreover, macroscopic observation was performed to make a comparative study between the directly-observed findings and MR findings. Fat-suppressed MR images were obtained sagittally by 3D-FLASH (fast low angle shot) sequence. The examined regions consisted of the following 4 sites; the medial condyle of the femur, its lateral condyle, the medial condyle of the tibia, and its lateral condyle. The revealed conditions of the cartilage were morphologically classified into 4 Stages. The evidence of cartilage defect on MR images was most frequently found at the medial condyle of the femur, with the medial condyle of the tibia, the lateral condyle of the femur, and the lateral condyle of the tibia following in a less frequent order. Fat-suppressed MRI's sensitivity to cartilage defect against macroscopy was 94.5%, specificity 95.4%, and accuracy 95.2%. MR imaging using fat-suppression can reveal cartilaginous degeneration and defect so well that this technique provides an important indication for selecting a proper method of treatment. (author)

  19. Surface severe plastic deformation of AISI 304 via conventional shot peening, severe shot peening and repeening

    Energy Technology Data Exchange (ETDEWEB)

    Unal, Okan, E-mail: unalokan78@gmail.com [Mechanical Engineering Department, Bartın University, Bartın 74100 (Turkey); Varol, Remzi [Mechanical Engineering Department, Suleyman Demirel University, Isparta 32200 (Turkey)

    2015-10-01

    Highlights: • CSP and SSP treatments transform austenite to metastable martensite structure. • Nanograin layer thickness after CSP and SSP is 8 μm and 22 μm, respectively. • Shot peening leads to carbon segregation from coarse to nano grain layer. • Repeening is an effective way to reduce surface roughness. - Abstract: Air blast conventional shot peening (CSP), severe shot peening (SSP) and repeening (RP) as a severe plastic deformation applications on AISI 304 austenitic stainless steel is addressed. Shot peened specimens are investigated based on optical, FESEM and digital microscope. The investigations present the austenite transformation to metastable martensite via mechanical twinning due to plastic deformation with high strain rates. It is found that SSP induces thicker nanograin layer with compared to CSP. In XRD studies, the austenite peaks broaden by means of severe shot peening and FWHM increase reveals the grain size reduction below 25 nm regimes on the surface. In EDAX line analysis of CSP specimen, carbon content increase has been detected from deformed layer through the nanocrystalline layer then the content reduces. The carbon segregation takes place due to the energy level distinction between dislocations and Fe−C bonds. 3d contour digital microscope studies and roughness investigations reveal that SSP has deleterious side effect on the surface roughness and surface flatness. However, RP is an effective way to reduce the surface roughness to reasonable values.

  20. Frequency and contributing factors for acute pancreatitis after endoscopic retrograde cholangiopancreatography in patients with obstructive jaundice

    International Nuclear Information System (INIS)

    Zubair, M.; Zaidi, A.R.; Hyder, A.

    2017-01-01

    To evaluate the frequency and contributing factors for acute pancreatitis after endoscopic retrograde cholangio-pancreatography in patients with obstructive jaundice. Study Design: Descriptive case series. Place and Duration of Study: A descriptive case series conducted at department of Gastroenterology, Shaikh Zayed Hospital, Lahore in the period of six months. Material and Methods: Two hundred and thirty patients diagnosed as having obstructive jaundice and undergoing ERCP who fulfilled the inclusion criteria were included in the study from the outpatient and indoor department of Gastroenterology-Hepatology Shaikh Zayed Hospital Lahore. Informed consent was taken. After the selection of the cases, patients were evaluated for the presence or absence of contributing factors like age, gender, cannulation attempts, cannulation time, percutaneous papillotomy, pancreatic duct contrast injection and previous history of post ERCP pancreatitis. Data was analysed by using the statistical software for social sciences (SPSS) version 15. Results: In our study, mean age was 44 +- 14.12 years. Out of 230 patients 42.17% (n=97) were male and 57.83% (n=133) were females. Frequency of acute pancreatitis after ERCP in patients with obstructive jaundice was 4.78% (n=11) while 95.22% (n=219) had no findings of acute pancreatitis after ERCP. Frequency of factors for acute pancreatitis after endoscopic retrograde cholangiopancreatography in patients with obstructive jaundice was recorded which shows that out of 11 cases, 45.45% (n=5) were females, 36.36% (n=4) had previous history of Post ERCP Pancreatitis, 27.27% (n=3) had >5 attempts of cannulation, 36.36% (n=4) had >5 minute time for cannulation, 54.55% (n=6) had pre-cut papillotomy while 63.64% (n=7) had pancreatic duct contrast injection. Conclusion: We concluded that frequency of acute pancreatitis after endoscopic retrograde cholangiopancreatography in patients with obstructive jaundice was found not very high in our practice

  1. Single-shot spiral imaging at 7 T.

    Science.gov (United States)

    Engel, Maria; Kasper, Lars; Barmet, Christoph; Schmid, Thomas; Vionnet, Laetitia; Wilm, Bertram; Pruessmann, Klaas P

    2018-03-25

    The purpose of this work is to explore the feasibility and performance of single-shot spiral MRI at 7 T, using an expanded signal model for reconstruction. Gradient-echo brain imaging is performed on a 7 T system using high-resolution single-shot spiral readouts and half-shot spirals that perform dual-image acquisition after a single excitation. Image reconstruction is based on an expanded signal model including the encoding effects of coil sensitivity, static off-resonance, and magnetic field dynamics. The latter are recorded concurrently with image acquisition, using NMR field probes. The resulting image resolution is assessed by point spread function analysis. Single-shot spiral imaging is achieved at a nominal resolution of 0.8 mm, using spiral-out readouts of 53-ms duration. High depiction fidelity is achieved without conspicuous blurring or distortion. Effective resolutions are assessed as 0.8, 0.94, and 0.98 mm in CSF, gray matter and white matter, respectively. High image quality is also achieved with half-shot acquisition yielding image pairs at 1.5-mm resolution. Use of an expanded signal model enables single-shot spiral imaging at 7 T with unprecedented image quality. Single-shot and half-shot spiral readouts deploy the sensitivity benefit of high field for rapid high-resolution imaging, particularly for functional MRI and arterial spin labeling. © 2018 International Society for Magnetic Resonance in Medicine.

  2. Collider shot setup for Run 2 observations and suggestions

    International Nuclear Information System (INIS)

    Annala, J.; Joshel, B.

    1996-01-01

    This note is intended to provoke discussion on Collider Run II shot setup. We hope this is a start of activities that will converge on a functional description of what is needed for shot setups in Collider Run II. We will draw on observations of the present shot setup to raise questions and make suggestions for the next Collider run. It is assumed that the reader has some familiarity with the Collider operational issues. Shot setup is defined to be the time between the end of a store and the time the Main Control Room declares colliding beams. This is the time between Tevatron clock events SCE and SCB. This definition does not consider the time experiments use to turn on their detectors. This analysis was suggested by David Finley. The operational scenarios for Run II will require higher levels of reliability and speed for shot setup. See Appendix I and II. For example, we estimate that a loss of 3 pb -1 /week (with 8 hour stores) will occur if shot setups take 90 minutes instead of 30 minutes. In other words: If you do 12 shots for one week and accept an added delay of one minute in each shot, you will loose more than 60 nb -1 for that week alone (based on a normal shot setup of 30 minutes). These demands should lead us to be much more pedantic about all the factors that affect shot setups. Shot setup will be viewed as a distinct process that is composed of several inter- dependent 'components': procedures, hardware, controls, and sociology. These components don't directly align with the different Accelerator Division departments, but are topical groupings of the needed accelerator functions. Defining these components, and categorizing our suggestions within them, are part of the goal of this document. Of course, some suggestions span several of these components

  3. Hepatitis A and the Vaccine (Shot) to Prevent It

    Science.gov (United States)

    ... Resources Maternal Immunization Resources Related Links Vaccines & Immunizations Hepatitis A and the Vaccine (Shot) to Prevent It ... the vaccine. Why should my child get the hepatitis A shot? The hepatitis A shot: Protects your ...

  4. Parallel imaging enhanced MR colonography using a phantom model.

    LENUS (Irish Health Repository)

    Morrin, Martina M

    2008-09-01

    To compare various Array Spatial and Sensitivity Encoding Technique (ASSET)-enhanced T2W SSFSE (single shot fast spin echo) and T1-weighted (T1W) 3D SPGR (spoiled gradient recalled echo) sequences for polyp detection and image quality at MR colonography (MRC) in a phantom model. Limitations of MRC using standard 3D SPGR T1W imaging include the long breath-hold required to cover the entire colon within one acquisition and the relatively low spatial resolution due to the long acquisition time. Parallel imaging using ASSET-enhanced T2W SSFSE and 3D T1W SPGR imaging results in much shorter imaging times, which allows for increased spatial resolution.

  5. Contrast-enhanced dynamic MR imaging in rheumatoid arthritis

    International Nuclear Information System (INIS)

    Koenig, H.; Sieper, J.; Wolf, K.J.

    1989-01-01

    This paper reports on a study for the identification of different pannus formations. Twenty patients with advanced rheumatoid arthritis of the knee joint were examined with MR imaging primary to surgery. The authors used a 1.5-T Magnetom unit, a circular surface coil for signal detection, 0.1 mmol/kg of Gd-DTPA given as a bolus injection, fast low-angle shot (FLASH) sequence (TR, 30 msec; TE, 10 msec; 128 x 128 matrix; excitation angle, 70 degrees) repeated 30 times within 120 seconds, and a T1-weighted spin-echo sequence (Tr, 500 msec; TE, 22 msec) before and 2 minutes after contrast medium injection. Enhancement of pannus and joint effusion has been measured and standardized to muscle tissue

  6. Bedside Endoscopic Retrograde Cholangiopancreatography Using Portable X-Ray in Acute Severe Cholangitis

    Directory of Open Access Journals (Sweden)

    Rushikesh Shah

    2018-01-01

    Full Text Available Patients with acute cholangitis require emergent biliary decompression. Those who are hemodynamically unstable on vasopressor support and mechanical ventilation are too critically ill to move outside of the intensive care unit. This prohibits performing Endoscopic Retrograde Cholangiopancreatography (ERCP in the endoscopy unit. Fluoroscopic guidance is required to confirm deep biliary cannulation during ERCP. There are a few reported cases of bedside ERCP using portable C-arm fluoroscopy unit or ultrasound guided cannulation. We present a unique case of life-saving emergent bedside ERCP in a severely ill patient with cholangitis and septic shock, using simple portable X-ray to confirm biliary cannulation.

  7. Preoperative local MRI-staging of patients with a suspected pancreatic mass.

    Science.gov (United States)

    Fischer, U; Vosshenrich, R; Horstmann, O; Becker, H; Salamat, B; Baum, F; Grabbe, E

    2002-02-01

    The aim of this study was to define the value of MRI of the pancreas for preoperative local staging of patients with a suspected pancreatic mass. Ninety-four patients (41 women, 53 men; age range 32-87 years) with a suspected pancreatic tumor underwent preoperative staging with MRI on a 1.5-T system. The MRI protocol included breath-hold MR cholangiopancreatography in turbo spin-echo technique, biphasic contrast-enhanced 3D MR angiography, and MRI of the upper abdomen with breath-hold T2-weighted half-Fourier acquired single-shot turbo spin-echo and T1-weighted fast-low-angle-shot (pre- and postcontrast) sequences. Data were collected prospectively and analyzed by two radiologists in agreement modality. Evaluation criteria were vascular involvement, resectability, and a characterization benign vs malignant. Results were compared to histopathology in 78 patients. Sixteen patients were followed-up. In 74 of 94 patients a solid tumor or an inflammation of the pancreas ( n=62) or the papilla ( n=12) was detected. In this group, MRI had a sensitivity of 98%, a specificity of 92%, and an accuracy of 96% in the characterization of malignant tumors. Regarding only the solid tumors, the positive predictive value of MRI was 87% with respect to resectability. Other pathologic findings included adenoma or inflammation of the duodenum ( n=5), carcinoma or benign stenosis of the choledochus duct ( n=7) and carcinoma of the gall bladder ( n=2). In 6 patients MRI did not depict any pathologic findings, and follow-up confirmed this interpretation. Magnetic resonance imaging allows a local preoperative staging in patients with suspected pancreatic tumor. Limitations, however, concern to the diagnostics of peritoneal and/or liver metastases.

  8. SunShot Initiative Portfolio Book 2014

    Energy Technology Data Exchange (ETDEWEB)

    Solar Energy Technologies Office

    2014-05-01

    The 2014 SunShot Initiative Portfolio Book outlines the progress towards the goals outlined in the SunShot Vision Study. Contents include overviews of each of SunShot’s five subprogram areas, as well as a description of every active project in the SunShot’s project portfolio as of May 2014.

  9. Spectrometer for shot-to-shot photon energy characterization in the multi-bunch mode of the free electron laser at Hamburg

    International Nuclear Information System (INIS)

    Palutke, S.; Wurth, W.; Gerken, N. C.; Mertens, K.; Klumpp, S.; Martins, M.; Mozzanica, A.; Schmitt, B.; Wunderer, C.; Graafsma, H.; Meiwes-Broer, K.-H.

    2015-01-01

    The setup and first results from commissioning of a fast online photon energy spectrometer for the vacuum ultraviolet free electron laser at Hamburg (FLASH) at DESY are presented. With the use of the latest advances in detector development, the presented spectrometer reaches readout frequencies up to 1 MHz. In this paper, we demonstrate the ability to record online photon energy spectra on a shot-to-shot base in the multi-bunch mode of FLASH. Clearly resolved shifts in the mean wavelength over the pulse train as well as shot-to-shot wavelength fluctuations arising from the statistical nature of the photon generating self-amplified spontaneous emission process have been observed. In addition to an online tool for beam calibration and photon diagnostics, the spectrometer enables the determination and selection of spectral data taken with a transparent experiment up front over the photon energy of every shot. This leads to higher spectral resolutions without the loss of efficiency or photon flux by using single-bunch mode or monochromators

  10. Bond strength investigation of two shot moulded polymer

    DEFF Research Database (Denmark)

    Islam, Mohammad Aminul

    This report on the project “Bond strength investigation of two shot moulded polymers” has been submitted for fulfilling the requirements for the course “Experimental Plastic Technology – 42234” at IPL-DTU. Two shot moulding is a classic manufacturing process to combine two different polymers...... in a single product and it is getting more and more importance day by day. One of the biggest challenges of two shot moulding is to achieve a reasonably good bonding between two polymers. The purpose of this project is to investigate the effects of different process, material and machine parameters...... on the bond strength of two shot moulded polymers. For the experiments two engineering polymers (PS and ABS) were used. After all the experimental work, several parameters were found which could effectively control the bond strength of two shot moulded polymers. This report also presents different aspects...

  11. Toxicity of Lead and Proposed Substitute Shot to Mallards

    Science.gov (United States)

    Longcore, J.R.; Andrews, R.; Locke, L.N.; Bagley, George E.; Young, L.T.

    1974-01-01

    Poisoning of North American waterfowl resulting from the ingestion of lead shot by ducks, geese, and swans causes an estimated annual mortality of 2 to 3% of the population (Bellrose 1959). To alleviate this problem the search for a suitable substitute for lead has been underway since the early 1950's. Proposed substitutes for lead shot were evaluated in a series of acute toxicity tests with pen-reared mallards (Anas platyrhynchos). Most candidate materials were as toxic to ducks as commercial lead shot. Coating or alloying lead with other metals only delayed mortality among dosed ducks. The reputedly 'disintegrable' lead shot with the water-soluble binder and the lead containing biochemical additives were also as toxic to mallards as the commercial lead shot. Mortality was not significantly different among lead-dosed adult or first-year hen and drake pen-reared mallards; lead-dosed adult, wild mallards of both sexes; and lead-dosed adult, male black ducks (Anas rubripes). The ingestion of one lead shot, size 4, by each of 80 pen-reared mallards caused an average 19% mortality. The presence and type of grit in the gizzard had a measurable effect on erosion of ingested shot and on shot retention among dosed mallards. Significantly fewer lead-dosed ducks died when fed crushed oystershell grit than when fed either quartz grit or no grit.

  12. Diagnosis of choledocholithiasis and therapeutic results with endoscopic retrograde cholangiopancreatography

    International Nuclear Information System (INIS)

    Ramos Pachon, Carlos; Gonzalez Cansino, Juan; Fernandez Maderos, Irma

    2009-01-01

    A descriptive, prospective study was carried out on 451 patients that were attended for endoscopic retrograde cholangiopancreatography at CIMEQ's Hospital from January 2004-March 2006. The sample was constituted by 353 patients with choledocholithiasis suspicion. The information was search in the reports of ERCP and the variables were analyzed with the objective of evaluating the diagnostic possibilities and the therapy for choledocholithiasis by ERCP. Choledocholithiasis was detected in 1/4 of the patients with indication of ERCP, and was more frequent in patients of the female sex and in patients older than 40 years. The jaundice was the main clinical condition that motivated the ERCP in the patients with choledocholithiasis. The diagnostic effectiveness of the alkaline phosphatase and the ultrasound was not high. The treatment of the choledocholithiasis by means of ERCP showed good results and low morbidity

  13. One-shot synesthesia

    Directory of Open Access Journals (Sweden)

    Kirschner Alexandra

    2017-11-01

    Full Text Available Synesthesia is commonly thought to be a phenomenon of fixed associations between an outside inducer and a vivid concurrent experience. Hence, it has been proposed that synesthesia occurs due to additional connections in the brain with which synesthetes are born. Here we show that synesthesia can be a much richer and more flexible phenomenon with a capability to creatively construct novel synesthetic experiences as events unfold in people’s lives. We describe here cases of synesthetes who occasionally generate novel synesthetic experience, called one-shot synesthesias. These synesthetic experiences seem to share all the properties with the classical synesthetic associations except that they occur extremely rarely, people recalling only a few events over the lifetime. It appears that these one-shots are not created at random but are instead responses to specific life events. We contrast the properties of those rare synesthetic events with other, more commonly known forms of synesthesia that also create novel synesthetic experiences, but at a high rate—sometimes creating novel experiences every few seconds. We argue that one-shot synesthesias indicate that synesthetic associations are by their nature not prewired at birth but are dynamically constructed through mental operations and according to the needs of a synesthetic mind. Our conclusions have implications for understanding the biological underpinnings of synesthesia and the role the phenomenon plays in the lives of people endowed with synesthetic capacities.

  14. LOCUS MR: Localization of unaffected spins in MR tomography and MR spectroscopy

    International Nuclear Information System (INIS)

    Matthael, D.; Haase, A.

    1986-01-01

    Different pulse sequences have been proposed for localized in vivo MR spectroscopy. For localized MR tomography and MR spectroscopy, a method is proposed, dubbed LOCUS (LOCalization of Unaffected Spins) MR. The method uses the initial saturation of regions surrounding the region of interest (ROI) in the presence of gradients. This is followed by a conventional MR study of the unaffected ROI. In animals, human extremities, and phantoms, proton MR studies demonstrated that the method provides an optimal signal-to-noise ratio, an easily variable ROI, and ROI shim. The method can be combined with two- and three-dimensional imaging, and it allows localized measurement of MR parameters. The multinuclear capability is discussed

  15. Clinical application of multi-shot diffusion EPI in neurological disease

    International Nuclear Information System (INIS)

    Ishihara, Tetsuya; Hirata, Koichi; Kubo, Jin; Yamazaki, Kaoru; Sato, Toshihiko

    1998-01-01

    Using the multi-shot EPI method we investigated the clinical application of diffusion weighted imaging (DWI) in the diagnosis of neurological disease. The multi-shot method provided better susceptibility artifact-free DWI than the single-shot method particularly in the region of the posterior cranial fossa. DWI using the multi-shot EPI method readily shows the pyramidal tract extending from the internal capsule to the brainstems which is inaccessible by the conventional single-shot EPI method, and providing three-dimensional and distinct images of pyramidal tract changes in amyotrophic lateral sclerosis or cerebral infarction with pyramidal tract disturbance. Our findings suggest that the use of DWI with the multi-shot EPI method would provide a technique for the easy diagnosis and evaluation of various neurological diseases. (author)

  16. Clinical application of multi-shot diffusion EPI in neurological disease

    Energy Technology Data Exchange (ETDEWEB)

    Ishihara, Tetsuya; Hirata, Koichi; Kubo, Jin; Yamazaki, Kaoru [Dokkyo Univ., Mibu, Tochigi (Japan). School of Medicine; Sato, Toshihiko

    1998-05-01

    Using the multi-shot EPI method we investigated the clinical application of diffusion weighted imaging (DWI) in the diagnosis of neurological disease. The multi-shot method provided better susceptibility artifact-free DWI than the single-shot method particularly in the region of the posterior cranial fossa. DWI using the multi-shot EPI method readily shows the pyramidal tract extending from the internal capsule to the brainstems which is inaccessible by the conventional single-shot EPI method, and providing three-dimensional and distinct images of pyramidal tract changes in amyotrophic lateral sclerosis or cerebral infarction with pyramidal tract disturbance. Our findings suggest that the use of DWI with the multi-shot EPI method would provide a technique for the easy diagnosis and evaluation of various neurological diseases. (author)

  17. A newly developed MR simulation system for intracavitary brachytherapy for cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ebe, Kazuyu; Matsunaga, Naofumi [Yamaguchi Univ., Ube (Japan). School of Medicine

    1997-03-01

    We have developed a prototype system for a magnetic resonance (MR) simulation to accurately estimate radiation doses to the tumor and surrounding normal tissues during brachytherapy for cervical cancer. Six patients with cervical cancer underwent MR simulation prior to intracavitary high-dose-rate brachytherapy using Co-60 sources. Tandem and ovoid applicators filled with tap-water were placed in the uterine cavity and vaginal fornix, then MR imaging examinations were performed. Frontal and lateral images of maximum intensity projection (MIP) of applicators generated from a data set of half-Fourier single shot turbo spin-echo (HASTE) images were chosen for processing by the treatment planning computer system. Then, isodose curves on the coronal or sagittal plane of the tandem section were superimposed on corresponding T2-weighted images derived from a turbo spin-echo technique. Doses to the tumor, the posterior wall of the urinary bladder, the anterior wall of the rectum, and the urethra were read from isodose curves superimposed on the T2-weighted sagittal image. Phantom experiments were done to evaluate geometrical errors. The possible distortion of the lattice image on the phantom was small. This system promises to be useful in customizing the dose distribution corresponding to the tumor and surrounding normal tissues. (author)

  18. A newly developed MR simulation system for intracavitary brachytherapy for cervical cancer

    International Nuclear Information System (INIS)

    Ebe, Kazuyu; Matsunaga, Naofumi

    1997-01-01

    We have developed a prototype system for a magnetic resonance (MR) simulation to accurately estimate radiation doses to the tumor and surrounding normal tissues during brachytherapy for cervical cancer. Six patients with cervical cancer underwent MR simulation prior to intracavitary high-dose-rate brachytherapy using Co-60 sources. Tandem and ovoid applicators filled with tap-water were placed in the uterine cavity and vaginal fornix, then MR imaging examinations were performed. Frontal and lateral images of maximum intensity projection (MIP) of applicators generated from a data set of half-Fourier single shot turbo spin-echo (HASTE) images were chosen for processing by the treatment planning computer system. Then, isodose curves on the coronal or sagittal plane of the tandem section were superimposed on corresponding T2-weighted images derived from a turbo spin-echo technique. Doses to the tumor, the posterior wall of the urinary bladder, the anterior wall of the rectum, and the urethra were read from isodose curves superimposed on the T2-weighted sagittal image. Phantom experiments were done to evaluate geometrical errors. The possible distortion of the lattice image on the phantom was small. This system promises to be useful in customizing the dose distribution corresponding to the tumor and surrounding normal tissues. (author)

  19. Optimisation of the MR protocol in pregnant women with suspected acute appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ilah; Chung, Yong Eun; An, Chansik; Kim, Honsoul; Lim, Joon Seok; Kim, Myeong-Jin [Yonsei University College of Medicine, Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Seoul (Korea, Republic of); Lee, Hye Sun [Yonsei University College of Medicine, Department of Research Affairs, Biostatistics Collaboration Unit, Seoul (Korea, Republic of)

    2018-02-15

    To investigate the optimal magnetic resonance (MR) imaging protocol in pregnant women suspected of having acute appendicitis. One hundred and forty-six pregnant women with suspected appendicitis were included. MR images were reviewed by two radiologists in three separate sessions. In session 1, only axial single-shot turbo spin echo (SSH-TSE) T2-weighted images (WI) were included with other routine sequences. In sessions 2 and 3, coronal and sagittal T2WI were sequentially added. The visibility of the appendix and diagnostic confidence of appendicitis were evaluated in each session using a 5-point grading scale. If diseases other than appendicitis were suspected, specific diagnosis with a 5-point confidence scale was recorded. Diagnostic performance for appendicitis and other diseases were evaluated. Twenty-five patients (17.1%) were diagnosed with appendicitis. Among the patients with normal appendix, 28 were diagnosed with other disease. Diagnostic performance including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and area under the curve values for diagnosing appendicitis and other diseases showed no significant difference among sets for both reviewers (p>0.05). Diagnostic performance of MR in pregnant patients with suspected appendicitis can be preserved with omission of sagittal or both coronal and sagittal SSH-T2WI. (orig.)

  20. Optimisation of the MR protocol in pregnant women with suspected acute appendicitis

    International Nuclear Information System (INIS)

    Shin, Ilah; Chung, Yong Eun; An, Chansik; Kim, Honsoul; Lim, Joon Seok; Kim, Myeong-Jin; Lee, Hye Sun

    2018-01-01

    To investigate the optimal magnetic resonance (MR) imaging protocol in pregnant women suspected of having acute appendicitis. One hundred and forty-six pregnant women with suspected appendicitis were included. MR images were reviewed by two radiologists in three separate sessions. In session 1, only axial single-shot turbo spin echo (SSH-TSE) T2-weighted images (WI) were included with other routine sequences. In sessions 2 and 3, coronal and sagittal T2WI were sequentially added. The visibility of the appendix and diagnostic confidence of appendicitis were evaluated in each session using a 5-point grading scale. If diseases other than appendicitis were suspected, specific diagnosis with a 5-point confidence scale was recorded. Diagnostic performance for appendicitis and other diseases were evaluated. Twenty-five patients (17.1%) were diagnosed with appendicitis. Among the patients with normal appendix, 28 were diagnosed with other disease. Diagnostic performance including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and area under the curve values for diagnosing appendicitis and other diseases showed no significant difference among sets for both reviewers (p>0.05). Diagnostic performance of MR in pregnant patients with suspected appendicitis can be preserved with omission of sagittal or both coronal and sagittal SSH-T2WI. (orig.)

  1. Spent shot availability and ingestion on areas managed for mourning doves

    Science.gov (United States)

    Schulz, J.H.; Millspaugh, J.J.; Washburn, B.E.; Wester, G.R.; Lanigan, J. T.; Franson, J.C.

    2002-01-01

    Mourning dove (Zenaida macroura) hunting is becoming increasingly popular, especially in managed shooting fields. Given the possible increase in the availability of lead (Pb) shot on these areas, our objective was to estimate availability and ingestion of spent shot at the Eagle Bluffs Conservation Area (EBCA, hunted with nontoxic shot) and the James A. Reed Memorial Wildlife Area (JARWA, hunted with Pb shot) in Missouri. During 1998, we collected soil samples one or 2 weeks prior to the hunting season (prehunt) and after 4 days of dove hunting (posthunt). We also collected information on number of doves harvested, number of shots fired, shotgun gauge, and shotshell size used. Dove carcasses were collected on both areas during 1998-99. At EBCA, 60 hunters deposited an estimated 64,775 pellets/ha of nontoxic shot on or around the managed field. At JARWA, approximately 1,086,275 pellets/ha of Pb shot were deposited by 728 hunters. Our posthunt estimates of spent-shot availability from soil sampling were 0 pellets/ha for EBCA and 6,342 pellets/ha for JARWA. Our findings suggest that existing soil sampling protocols may not provide accurate estimates of spent-shot availability in managed dove shooting fields. During 1998-99, 15 of 310 (4.8%) mourning doves collected from EBCA had ingested nontoxic shot. Of those doves, 6 (40.0%) contained a?Y7 shot pellets. In comparison, only 2 of 574 (0.3%) doves collected from JARWA had ingested Pb shot. Because a greater proportion of doves ingested multiple steel pellets compared to Pb pellets, we suggest that doves feeding in fields hunted with Pb shot may succumb to acute Pb toxicosis and thus become unavailable to harvest, resulting in an underestimate of ingestion rates. Although further research is needed to test this hypothesis, our findings may partially explain why previous studies have shown few doves with ingested Pb shot despite their feeding on areas with high Pb shot availability.

  2. Removal of Retained Lead Shot Through Laparoscopic Appendectomy

    Science.gov (United States)

    Lloyd, D. M.

    2003-01-01

    We describe a patient presenting with lead shot in his appendix. A plain radiograph of his lumbar spine was performed for back pain, and an incidental finding of lead shot retained within the appendix was seen. Lead shot in the appendix is associated with appendicitis, and 2 cases have been reported of lead intoxication. We suggest that an elective laparoscopic appendectomy should be offered to patients as a possible management option. PMID:12856854

  3. [Contact shot from infantry weapons with a flash-suppressor].

    Science.gov (United States)

    Perdekamp, Markus Grosse; Braunwarth, Roland; Schmidt, Ulrike; Schmidt, Wolfgang; Pollak, Stefan

    2003-01-01

    The number of reports on contact shots from firearms with a flash suppressor attached to the muzzle is small. On the basis of a case report (suicidal shot to the forehead with a Kalschnikow AKMS 47 assault rifle) the morphological peculiarities (characteristics soot pattern, relatively small powder cavity and only minor skin tears in the presence of a bony support) are presented and the conclusions to be drawn from the findings regarding the flash-suppressor, the shot distance, the angle of the shot and the way of holding the weapon are discussed.

  4. Initial experience in perfusion MR imaging of intracranial major artery occlusion with echo-planar technique

    International Nuclear Information System (INIS)

    Tsuchiya, Kazuhiro; Mizutani, Yoshiyuki; Inaoka, Sayuki; Hachiya, Junichi

    1997-01-01

    The purpose of this study was to evaluate the usefulness of perfusion MR imaging using a single-shot echo-planar technique in occlusion of intracranial main arteries. Our patient group consisted of 16 patients with internal carotid artery occlusion (n=9), Moyamoya disease (n=4), and middle cerebral artery occlusion (n=3). We performed the echo-planar perfusion studies with a 1.5-T unit using a free-induction-decay-type echo-planar sequence. With a bolus injection of Gd-DTPA, 30 consecutive scans were obtained at 10 sections every 2 seconds. The data were analyzed in three ways: a time-intensity curves in the territory of the involved artery (n=16); semiquantitative flow map of each section representing signal changes due to passage of Gd-DTPA (n=15); and serial images at a selected section (n=7). The time intensity curves were abnormal in 13 patients. The peak of signal drop was delayed in all of them. Flow maps showed focal flow abnormalities in 11 patients, but they were apparently normal in 4 patients probably due to collateral flow. In serial images, delay in appearance and/or disappearance of Gd-DTPA was noted in 6 patients. In patients with occlusion of intracranial main arteries, MR single-shot echo-planar technique is of clinical use because it can provide information about hemodynamic changes in a short examination time, in multiple sections, and with good temporal resolution. (author)

  5. Importance of early diagnosis of pancreaticobiliary maljunction without biliary dilatation

    Science.gov (United States)

    Takuma, Kensuke; Kamisawa, Terumi; Tabata, Taku; Hara, Seiichi; Kuruma, Sawako; Inaba, Yoshihiko; Kurata, Masanao; Honda, Goro; Tsuruta, Koji; Horiguchi, Shin-ichiro; Igarashi, Yoshinori

    2012-01-01

    AIM: To clarify the strategy for early diagnosis of pancreaticobiliary maljunction (PBM) without biliary dilatation and to pathologically examine gallbladder before cancer develops. METHODS: The anatomy of the union of the pancreatic and bile ducts was assessed by using endoscopic retrograde cholangiopancreatography (ERCP). Patients with a long common channel in which communication between the pancreatic and bile ducts was maintained even during sphincter contraction were diagnosed as having PBM. Of these, patients in which the maximal diameter of the bile duct was less than 10 mm were diagnosed with PBM without biliary dilatation. The process of diagnosing 54 patients with PBM without biliary dilatation was retrospectively investigated. Histopathological analysis of resected gallbladder specimens from 8 patients with PBM without biliary dilatation or cancer was conducted. RESULTS: Thirty-six PBM patients without biliary dilatation were diagnosed with gallbladder cancer after showing clinical symptoms such as abdominal or back pain (n = 16) or jaundice (n = 12). Radical surgery for gallbladder cancer was only possible in 11 patients (31%) and only 4 patients (11%) survived for 5 years. Eight patients were suspected as having PBM without biliary dilatation from the finding of gallbladder wall thickening on ultrasound and the diagnosis was confirmed by ERCP and/or magnetic resonance cholangiopancreatography (MRCP). The median age of these 8 patients was younger by a decade than PBM patients with gallbladder cancer. All 8 patients underwent prophylactic cholecystectomy and bile duct cancer has not occurred. Wall thickness and mucosal height of the 8 resected gallbladders were significantly greater than controls, and hyperplastic changes, hypertrophic muscular layer, subserosal fibrosis, and adenomyomatosis were detected in 7 (88%), 5 (63%), 7 (88%) and 5 (63%) patients, respectively. Ki-67 labeling index was high and K-ras mutation was detected in 3 of 6 patients

  6. Ultra-high-speed inversion recovery echo planar MR imaging

    International Nuclear Information System (INIS)

    Stehling, M.K.; Ordidge, R.J.; Coxon, R.; Chapman, B.; Houseman, A.M.; Guifoyle, D.; Blamire, A.; Gibbs, P.; Mansfield, P.

    1988-01-01

    Fast two-dimensional FT MR imaging techniques such as fast low-angle shot do not allow inversion recovery (IR). Rapid repetition of low-angle pulses is incompatible with a 180 0 inversion pulse. Echo planar imaging (EPI) can be applied in conjunction with IR, because after preparation of the spin system, a complete image is acquired. Data acquisition in less than 100 msec and real-time display allows interactive optimization of inversion time (4.0-9,000 msec) with little time penalty. The authors have applied IR EPI to the study of the brain, liver, and kidneys in normal volunteers and patients. Technical details are presented, and the applications of this first ultra-high-speed IR technique will be shown

  7. Activities in a social networking-based discussion group by endoscopic retrograde cholangiopancreatography doctors.

    Science.gov (United States)

    Kang, Xiaoyu; Zhao, Lina; Liu, Na; Wang, Xiangping; Zhang, Rongchun; Liu, Zhiguo; Liang, Shuhui; Yao, Shaowei; Tao, Qin; Jia, Hui; Pan, Yanglin; Guo, Xuegang

    2017-10-01

    Online social networking is increasingly being used among medical practitioners. However, few studies have evaluated its use in therapeutic endoscopy. Here, we aimed to analyze the shared topics and activities of a group of endoscopic retrograde cholangiopancreatography (ERCP) doctors in a social networking-based endoscopic retrograde cholangiopancreatography discussion group (EDG). Six ERCP trainers working in Xijing Hospital and 48 graduated endoscopists who had finished ERCP training in the same hospital were invited to join in EDG. All group members were informed not to divulge any private information of patients when using EDG. The activities of group members on EDG were retrospectively extracted. The individual data of the graduated endoscopists were collected by a questionnaire. From June 2014 to May 2015, 6924 messages were posted on EDG, half of which were ERCP related. In total, 214 ERCP-related topics were shared, which could be categorized into three types: sharing experience/cases (52.3%), asking questions (38.3%), and sharing literatures/advances (9.3%). Among the 48 graduated endoscopists, 21 had a low case volume of less than 50 per year and 27 had a high volume case volume of 50 or more. High-volume graduated endoscopists posted more ERCP-related messages (P=0.008) and shared more discussion topics (P=0.003) compared with low-volume graduated endoscopists. A survey showed that EDG was useful for graduated endoscopists in ERCP performance and management of post-ERCP complications, etc. A wide range of ERCP-related topics were shared on the social networking-based EDG. The ERCP-related behaviors on EDG were more active in graduated endoscopists with an ERCP case volume of more than 50 per year.

  8. Retrograde cholangiopancreatography in the diagnosis of biliary and pancreatic duct diseases

    International Nuclear Information System (INIS)

    Vasil'ev, Yu.D.; Sedletskaya, T.N.

    1980-01-01

    Results of retrograde cannulation with the aid of flexible fibroduodenoscopes with subsequent introduction of a contrast substance into biliary and pancreatic ducts are presented. The investigation is carried out on 120 patients with different diseases of hepatopancreatoduodenal zone. The standard technique of X-ray examination has been applied permitting to obtain the most exhaustive information. Using retrograde cholangiopancreatography revealed have been choledocholithiasis, deformation of biliary ducts after surgical intervention, pancreatic cyst, tumor of the main pancreatic duct etc. Results of investigation of biliary and pancreatic ducts using retrograde cannulation are reaffirmed with the data of operations on biliary tract in 72 patients. Intraoperational cholangiography has been carried out on 36 of them during operation. An attempt to cannulate big duodenal papilla in 12 patients proved to be ineffective. No complications have been observed during examination

  9. SunShot Initiative Fact Sheet

    Energy Technology Data Exchange (ETDEWEB)

    DOE Solar Energy Technologies Office

    2015-04-01

    The U.S. Department of Energy (DOE) SunShot Initiative is a collaborative national effort launched in 2011 that aggressively drives innovation to make solar energy fully cost competitive with traditional energy sources before the end of the decade. The SunShot fact sheet outlines goals and successes of the program as it works with private companies, universities, non-profit organizations, state and local governments, and national laboratories to drive down the cost of solar electricity to $0.06 per kilowatt-hour, without incentives, by the year 2020.

  10. Diffusion weighted MR imaging of pancreatic islet cell tumors

    International Nuclear Information System (INIS)

    Bakir, Baris; Salmaslioglu, Artur; Poyanli, Arzu; Rozanes, Izzet; Acunas, Bulent

    2010-01-01

    Purpose: The aim of our study is to demonstrate the feasibility of body diffusion weighted (DW) MR imaging in the evaluation of pancreatic islet cell tumors (ICTs) and to define apparent diffusion coefficient (ADC) values for these tumors. Materials and methods: 12 normal volunteers and 12 patients with histopathologically proven pancreatic ICT by surgery were included in the study. DW MR images were obtained by a body-phased array coil using a multisection single-shot echo planar sequence on the axial plane without breath holding. In addition, the routine abdominal imaging protocol for pancreas was applied in the patient group. We measured the ADC value within the normal pancreas in control group, pancreatic ICT, and surrounding pancreas parenchyma. Mann-Whitney U-test has been used to compare ADC values between tumoral tissues and normal pancreatic tissues of the volunteers. Wilcoxon Signed Ranks Test was preferred to compare ADC values between tumoral tissues and surrounding pancreatic parenchyma of the patients. Results: In 11 patients out of 12, conventional MR sequences were able to demonstrate ICTs successfully. In 1 patient an indistinct suspicious lesion was noted at the pancreatic tail. DW sequence was able to demonstrate the lesions in all of the 12 patients. On the DW images, all ICTs demonstrated high signal intensity relative to the surrounding pancreatic parenchyma. The mean and standard deviations of the ADC values (x10 -3 mm 2 /s) were as follows: ICT (n = 12), 1.51 ± 0.35 (0.91-2.11), surrounding parenchyma (n = 11) 0.76 ± 0.15 (0.51-1.01) and normal pancreas in normal volunteers (n = 12), 0.80 ± 0.06 (0.72-0.90). ADC values of the ICT were significantly higher compared with those of surrounding parenchyma (p < 0.01) and normal pancreas (p < 0.001). Conclusion: DW MR imaging does not appear to provide significant contribution to routine MR imaging protocol in the evaluation of pancreatic islet cell tumors. But it can be added to MR imaging

  11. MR of the small bowel with a biphasic oral contrast agent (polyethylene glycol): technical aspects and findings in patients affected by Crohn's disease.

    Science.gov (United States)

    Laghi, Andrea; Paolantonio, Pasquale; Iafrate, Franco; Borrelli, Osvaldo; Dito, Lucia; Tomei, Ernesto; Cucchiara, Salvatore; Passariello, Roberto

    2003-01-01

    To report our experience using MR of the small bowel with polyethylene glycol (PEG) solution as an oral contrast agent in a population of adults and children with known Crohn's disease. 40 patients (29 males; 11 females), 15 adults (age range 24-52 years) and 25 children (age range 5-17 years), with known Crohn's disease, underwent MR of the small bowel using a supeconductive 1.5 T magnet, and polyethylene glycol solution as an oral contrast agent. The fixed amount of contrast agent was 750-1000 ml for adults and 10 ml/kg of body weight for children. The Crohn's Disease Activity Index (CDAI) was available in all patients. Our study protocol included the acquisition of T2-weighted half-Fourier single-shot turbo spin-echo (HASTE) sequences and true fast imaging in the steady-state precession (true-FISP) sequences, followed by the acquisition of "spoiled" 2D gradient echo T1-weighted sequences with fat suppression (FLASH, fast low-angle shot) or alternatively "spoiled" 3D (VIBE, volume interpolated breath-hold examination), acquired 70 seconds after intravenous administration of gadopentetate dimeglumine (Gd-DTPA) (0,1 mmol/kg). A specific MR score was created and calculated for each patient and was compared by means of the Spearman rank with CDAI. In all patients no significant side effects were observed and the MR examination was well tolerated even by paediatric patients. In all cases MR showed a small bowel wall thickening (> 4 mm) in the terminal ileum, with lumen stenosis in 26 patients. In 3 cases pathological segments proximal to the terminal ileum were observed and in another 3 cases caecal involvement was visible. The MR examination was able to show abnormalities of perivisceral fat tissue in 15 patients, mesenteric lymphadenopathy in 1 patient and abdominal abscess in 1 case. The Spearman rank showed a statistically significant correlation between CDAI and the MR score (r = 0.91, P = 0,0001). MR using PEG as an oral contrast agent could be considered a test

  12. What You Can Expect with a Cortisone Shot

    Science.gov (United States)

    ... should avoid before your cortisone shot. What you can expect During the cortisone shot Your doctor might ... ll then be positioned so that your doctor can easily insert the needle. The area around the ...

  13. Some properties of focus points in one-shot decision theory

    OpenAIRE

    Guo, Peijun

    2011-01-01

    One-shot (one-time) decision problems concern the situations where a decision is experienced only once. Such one-shot decision problems are commonly encountered in business, economics and social systems. One-shot decision theory has been initially proposed by Guo [4]. The one-shot decision procedure comprises two steps. In the first step, a decision maker identifies which state of nature should be taken into account for each alternative amongst all available states of nature. These identified...

  14. MRI of the abdomen – how we do it?

    International Nuclear Information System (INIS)

    Zlatanov, Y.; Penkov, M.

    2013-01-01

    Full text: Introduction: Currently MR tomography in comparison with multidetector CT plays a subordinate role in the diagnostic and imaging algorithm in the study of abdomen organs. However, technical innovation occurring in magnetic resonance imaging, allow us to obtain images with high resolution at an acceptable duration of the study. Moreover assessment of the condition of the biliary system can be optimized through the use of MR cysto- pancreatography that allows non-invasive assessment of pancreatic biliary system, and the use of MR angiography, which visualized in the abdominal vessels. What you will learn: methods for approach to patient for abdominal examination; the advantages and disadvantages of different MR sequences in imaging of organs and structures in the abdomen; the advantages and disadvantages of different types MR cysto- pancreatography for the purpose of magnetic resonance tomography in patients with diseases in the abdomen. Discussion: MR is used for diseases of the organs in the abdomen especially for diagnosis and staging of neoplastic processes, to differentiate between tumors and inflammatory processes, and in the characterization of the cystic lesion. MRI scan has three main tasks in the assessment of the conditions of the organs in the abdomen: should provide a definitive diagnosis in patients with inconclusive data on abdominal ultrasound or CT scan for any pathological process , must allow proper staging of malignancies in order to preoperative assessment of the state of patient and sometimes non-resectability of the tumor formations due to their advancing, should characterize cystic lesions whose frequency increases in the conduct of routine or diagnostic CT studies. Conclusion: As a result of rapid technological progress current protocols for MR examinations of the abdomen are very different from those used 10 years ago. Most sequences can be performed during one or more breath-hold cycle and 3D sequences with thin consecutive

  15. Endoscopic retrograde cholangiopancreatography, endoscopic esphinterotomy and laparoscopic cholecystectomy in a patient with choledocolitiasis and cholelitiasis

    International Nuclear Information System (INIS)

    Riveron Quevedo, Kelly; Irsula Ballaga, Vladimir; Gonzalez Ulloa, Lianne; Deborah LLorca, Armando

    2012-01-01

    The case report of a 30 year-old presumably healthy patient, who attended the Gastroenterology Department from 'Dr Juan Bruno Zayas Alfonso' Teaching General Hospital in Santiago de Cuba, and suffering from biliary cholic, ictero, choluria, nausea, vomit and loss of appetite is presented. The complementary examinations confirmed the choledocolitiasis and cholelitiasis diagnosis, reason why it was necessary to carry out a endoscopic retrograde cholangiopancreatography, endoscopic esphinterotomy and ambulatory laparoscopic cholecystectomy, in a single anesthetic injection. The postoperative clinical course was favorable and she was discharged without complications 24 hours before the intervention

  16. Comparison of optimization algorithms for the slow shot phase in HPDC

    Science.gov (United States)

    Frings, Markus; Berkels, Benjamin; Behr, Marek; Elgeti, Stefanie

    2018-05-01

    High-pressure die casting (HPDC) is a popular manufacturing process for aluminum processing. The slow shot phase in HPDC is the first phase of this process. During this phase, the molten metal is pushed towards the cavity under moderate plunger movement. The so-called shot curve describes this plunger movement. A good design of the shot curve is important to produce high-quality cast parts. Three partially competing process goals characterize the slow shot phase: (1) reducing air entrapment, (2) avoiding temperature loss, and (3) minimizing oxide caused by the air-aluminum contact. Due to the rough process conditions with high pressure and temperature, it is hard to design the shot curve experimentally. There exist a few design rules that are based on theoretical considerations. Nevertheless, the quality of the shot curve design still depends on the experience of the machine operator. To improve the shot curve it seems to be natural to use numerical optimization. This work compares different optimization strategies for the slow shot phase optimization. The aim is to find the best optimization approach on a simple test problem.

  17. Comparision between biphasic helical CT and dynamic gadolinium-enhanced MR in the detection and characterization of focal hepatic lesions in cirrhotic patients

    International Nuclear Information System (INIS)

    Puig, J.; Martin, J.; Donoso, L.; Falco, J.; Rue, M.

    1997-01-01

    To assess the agreement between biphasic helical computerized tomography (BHCT) and dynamic gadolinium-enhanced magnetic resonance (MR) in the detection and characterization of focal hepatic lesions in a group of cirrhotic patients. A prospective study was done in 50 cirrhotic patients suspected of having hepatocarcinoma (HC) on the basis of ultrasonographic images evaluated by means of BHCT and dynamic gadolinium-enhanced MR using fast low-angle shot (FLASH) sequences (110-135/4/90 degree centigree). The images were assessed jointly by four radiologists. Between the two techniques, a total of 83 lesions were detected. MR disclosed more lesions (n=79) than BHCT (n=67) (p<0.005). Moreover, 25 of the lesions that were visible by both techniques were more clearly evident in MR images (p<0.01). MR correctly classified 6 of 7 benign lesions (85%) and 49 of 66 malignant ones (74%). BHCT correctly classifed 2 of 7 benign lesions (28%) and 32 of 66 malignant ones (48%). The sensitivities of MR and BHCT for the characterization of these lesions were 74% and 48%, respectively (p=0.0009), while the respective specificities were 86% and 29% (P<0.001). Dynamic gadolinium-enhanced MR with FLASH sequences is more efficient than BHCT in the detection and characterization of focal lesions in cirrhotic patients. (Author) 37 refs

  18. Hepatocellular carcinoma with bile duct tumor thrombi: Correlation of magnetic resonance imaging features to histopathologic manifestations

    Energy Technology Data Exchange (ETDEWEB)

    Liu Qingyu, E-mail: liu.qingyu@163.co [Department of Radiology, Second Affiliated Hospital of Sun Yat-sen University, 107 Yan Jiang Xi Road, Guangzhou, 510120, Guangdong Province (China); Chen Jianyu, E-mail: chenjianyu5562@sina.co [Department of Radiology, The Second Affiliated Hospital of Sun Yat-sen University, 107 Yan Jiang Xi Road, Guangzhou, 510120, Guangdong Province (China); Li Haigang, E-mail: lhg00433@yahoo.com.c [Department of Pathology, Second Affiliated Hospital of Sun Yat-sen University, Guangzhou, Guangdong Province (China); Liang Biling, E-mail: liangbl@163.ne [Department of Radiology, Second Affiliated Hospital of Sun Yat-sen University, 107 Yan Jiang Xi Road, Guangzhou, 510120, Guangdong Province (China); Zhang Lei, E-mail: zhanglei646@126.co [Department of Hepatobiliary Surgery, Second Affiliated Hospital of Sun Yat-sen University, Guangzhou, Guangdong Province (China); Hu Tao, E-mail: htwuaini@hotmail.co [Department of Radiology, Second Affiliated Hospital of Sun Yat-sen University, 107 Yan Jiang Xi Road, Guangzhou, 510120, Guangdong Province (China)

    2010-10-15

    Purpose: This study was to analyze the magnetic resonance imaging (MRI) features of hepatocellular carcinoma (HCC) with bile duct tumor thrombi, and explore their correlations to histopathology to improve the accuracy of diagnosis. Materials and methods: 21 patients with pathologically confirmed HCC with bile duct tumor thrombi was performed with a superconducting 1.5-T MR imager within two weeks before operation. Magnetic resonance cholangiopancreatography (MRCP) was performed on 18 patients. Images were retrospectively assessed for the size, location and MRI manifestations of HCC lesions and associated bile duct tumor thrombi. The differentiation of HCC lesions and the pathologic changes of bile duct tumor thrombi were retrospectively analyzed under microscope. Results: The average diameter of HCC lesions was 5.8 {+-} 2.8 cm, and {<=}5.0 cm in nine cases. Capsule formation was observed on MRI or pathology in 4 cases of HCC (19%). Of the 21 cases with bile duct tumor thrombi, 20 were clearly presented on MRI as cord-like or columnar masses in the bile duct with proximal cholangiectasis. The tumor thrombi showed slightly hypointense on T1WI and slightly hyperintense on T2WI. On enhanced scan, three cases of tumor thrombi, which were mainly consisted of necrotic tissue, did not show enhancement; 17 cases, which were mainly consisted of cancer cells, showed mild or moderate enhancement. On magnetic resonance cholangiopancreatogram (MRCP), 14 cases of tumor thrombi presented as filling defect in the bile duct, abrupt obstruction of the bile duct, and cholangiectasis above the obstruction; four presented as dilated intra-hepatic bile ducts with missing common bile duct. Of the 21 patients, 16 had biliary hemorrhage; three also had tumor thrombi in the portal vein. Seventeen of the 21 HCC with biliary thrombi were poorly differentiated, unencapsulated and with an invasive growth. Nineteen of 21 bile duct tumor thrombi did not invade the bile duct wall and could be

  19. Hepatocellular carcinoma with bile duct tumor thrombi: Correlation of magnetic resonance imaging features to histopathologic manifestations

    International Nuclear Information System (INIS)

    Liu Qingyu; Chen Jianyu; Li Haigang; Liang Biling; Zhang Lei; Hu Tao

    2010-01-01

    Purpose: This study was to analyze the magnetic resonance imaging (MRI) features of hepatocellular carcinoma (HCC) with bile duct tumor thrombi, and explore their correlations to histopathology to improve the accuracy of diagnosis. Materials and methods: 21 patients with pathologically confirmed HCC with bile duct tumor thrombi was performed with a superconducting 1.5-T MR imager within two weeks before operation. Magnetic resonance cholangiopancreatography (MRCP) was performed on 18 patients. Images were retrospectively assessed for the size, location and MRI manifestations of HCC lesions and associated bile duct tumor thrombi. The differentiation of HCC lesions and the pathologic changes of bile duct tumor thrombi were retrospectively analyzed under microscope. Results: The average diameter of HCC lesions was 5.8 ± 2.8 cm, and ≤5.0 cm in nine cases. Capsule formation was observed on MRI or pathology in 4 cases of HCC (19%). Of the 21 cases with bile duct tumor thrombi, 20 were clearly presented on MRI as cord-like or columnar masses in the bile duct with proximal cholangiectasis. The tumor thrombi showed slightly hypointense on T1WI and slightly hyperintense on T2WI. On enhanced scan, three cases of tumor thrombi, which were mainly consisted of necrotic tissue, did not show enhancement; 17 cases, which were mainly consisted of cancer cells, showed mild or moderate enhancement. On magnetic resonance cholangiopancreatogram (MRCP), 14 cases of tumor thrombi presented as filling defect in the bile duct, abrupt obstruction of the bile duct, and cholangiectasis above the obstruction; four presented as dilated intra-hepatic bile ducts with missing common bile duct. Of the 21 patients, 16 had biliary hemorrhage; three also had tumor thrombi in the portal vein. Seventeen of the 21 HCC with biliary thrombi were poorly differentiated, unencapsulated and with an invasive growth. Nineteen of 21 bile duct tumor thrombi did not invade the bile duct wall and could be easily

  20. Sudden death after endoscopic retrograde cholangiopancreatography (ERCP)--case report and literature review.

    Science.gov (United States)

    Hauser, Goran; Milosevic, Marko; Zelić, Marko; Stimac, Davor

    2014-12-01

    There are only a few cases found in literature regarding air embolism in endoscopic procedures, especially in connection to endoscopic retrograde cholangiopancreatography (ERCP). We are presenting a case of a 56-year-old female patient who suffered from non-Hodgkin lymphoma located in her right groin. She was also diagnosed with choledocholithiasis and underwent ERCP to remove the gallstones. Immediately after the procedure she went into sudden cardiac arrest and subsequently died, despite all of our efforts. We reviewed literature in order to identify possible causes of death because fatal outcome following an uneventful and successful procedure was not expected. It is important to bear in mind all possible complications of ERCP. Our focus during the literature search was on air embolism.

  1. MR-guided MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Tratting, S.; Breitenseher, M.; Pretterklieber, M.; Kontaxis, G.; Rand, T.; Imhof, H.

    1996-01-01

    Purpose: To develop an MR-guided technique for joint puncture in MR arthrography of the shoulder and to confirm the intracapsular position of the needle tip by visualization of the flow of contrast media into the joint. Materials and methods: Three unfixed human shoulder joint specimens were examined on a 1.0 T unit. The optimal point of entrance and depth for joint puncture were estimated by means of MR-compatible markers on the skin. Needle orientation and localization of the needle tip (MR-compatible 22-gauge needle) in the shoulder joint were monitored by rapid localizer gradient-echo sequences in two orthogonal planes. To confirm the intracapsular position of the needle tip, diluted gadolinium-DTPA was administered via a long connecting tube and the flow of contrast media into the joint was viewed directly on an LCD screen using real-time MR imaging (local look technique). Results: The MR-compatible markers on the skin allowed determination of the optimal point of entrance and estimation of the depth for joint puncture. Passive visualization of the MR-compatible needle due to spin dephasing and signal loss provided adequate localization of the intra-articular needle tip position in all specimens, although significant artefacts were present on rapid localizer gradient-echo sequences with an increase in width of the apparent needle shaft. Real-time MR imaging of the flow of contrast media was possible using the local look technique and the LCD screen of the MR unit and allowed confirmation of the intracapsular position. Conclusion: MR-guided joint puncture and real-time MR-assisted contrast media application results in improved MR arthrography and may replace conventional fluoroscopic guidance. (orig.) [de

  2. Biomechanical Analysis of the Jump Shot in Basketball

    Directory of Open Access Journals (Sweden)

    Struzik Artur

    2014-10-01

    Full Text Available Basketball players usually score points during the game using the jump shot. For this reason, the jump shot is considered to be the most important element of technique in basketball and requires a high level of performance. The aim of this study was to compare the biomechanical characteristics of the lower limbs during a jump shot without the ball and a countermovement jump without an arm swing. The differences between variables provide information about the potential that an athlete can utilise during a game when performing a jump shot. The study was conducted among 20 second-league basketball players by means of a Kistler force plate and the BTS SMART system for motion analysis. The variables measured included the take-off time, mean power, peak power, relative mean power, jump height, maximum landing force and calculated impact ratio. Surprisingly, more advantageous variables were found for the jump shot. This finding suggests a very high performance level in the jump shot in the studied group and a maximum utilisation of their motor abilities. Both types of jumps were characterised by high mean and peak power values and average heights. The high forces at landing, which result in considerable impact ratios, may have prompted the studied group to land softly. Use of the countermovement jump without an arm swing is recommended to assess and predict the progression of player’s jumping ability

  3. Study on Plastic Deformation Characteristics of Shot Peening of Ni-Based Superalloy GH4079

    Science.gov (United States)

    Zhong, L. Q.; Liang, Y. L.; Hu, H.

    2017-09-01

    In this paper, the X-ray stress diffractometer, surface roughness tester, field emission scanning electron microscope(SEM), dynamic ultra-small microhardness tester were used to measure the surface residual stress and roughness, topography and surface hardness changes of GH4079 superalloy, which was processed by metallographic grinding, turning, metallographic grinding +shot peening and turning + shot peening. Analysized the effects of shot peening parameters on shot peening plastic deformation features; and the effects of the surface state before shot peening on shot peening plastic deformation characteristics. Results show that: the surface residual compressive stress, surface roughness and surface hardness of GH4079 superalloy were increased by shot peening, in addition, the increment of the surface residual compressive stress, surface roughness and surface hardness induced by shot peening increased with increasing shot peening intensity, shot peening time, shot peening pressure and shot hardness, but harden layer depth was not affected considerably. The more plastic deformation degree of before shot peening surface state, the less increment of the surface residual compressive stress, surface roughness and surface hardness induced by shot peening.

  4. Preoperative local MRI-staging of patients with a suspected pancreatic mass

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, U.; Vosshenrich, R.; Salamat, B.; Baum, F.; Grabbe, E. [Department of Radiology, Georg August University, Goettingen (Germany); Horstmann, O.; Becker, H. [Department of Surgery, Georg August University, Goettingen (Germany)

    2002-02-01

    The aim of this study was to define the value of MRI of the pancreas for preoperative local staging of patients with a suspected pancreatic mass. Ninety-four patients (41 women, 53 men; age range 32-87 years) with a suspected pancreatic tumor underwent preoperative staging with MRI on a 1.5-T system. The MRI protocol included breath-hold MR cholangiopancreatography in turbo spin-echo technique, biphasic contrast-enhanced 3D MR angiography, and MRI of the upper abdomen with breath-hold T2-weighted half-Fourier acquired single-shot turbo spin-echo and T1-weighted fast-low-angle-shot (pre- and postcontrast) sequences. Data were collected prospectively and analyzed by two radiologists in agreement modality. Evaluation criteria were vascular involvement, resectability, and a characterization benign vs malignant. Results were compared to histopathology in 78 patients. Sixteen patients were followed-up. In 74 of 94 patients a solid tumor or an inflammation of the pancreas (n=62) or the papilla (n=12) was detected. In this group, MRI had a sensitivity of 98%, a specificity of 92%, and an accuracy of 96% in the characterization of malignant tumors. Regarding only the solid tumors, the positive predictive value of MRI was 87% with respect to resectability. Other pathologic findings included adenoma or inflammation of the duodenum (n=5), carcinoma or benign stenosis of the choledochus duct (n=7) and carcinoma of the gall bladder (n=2). In 6 patients MRI did not depict any pathologic findings, and follow-up confirmed this interpretation. Magnetic resonance imaging allows a local preoperative staging in patients with suspected pancreatic tumor. Limitations, however, concern to the diagnostics of peritoneal and/or liver metastases. (orig.)

  5. Preoperative local MRI-staging of patients with a suspected pancreatic mass

    International Nuclear Information System (INIS)

    Fischer, U.; Vosshenrich, R.; Salamat, B.; Baum, F.; Grabbe, E.; Horstmann, O.; Becker, H.

    2002-01-01

    The aim of this study was to define the value of MRI of the pancreas for preoperative local staging of patients with a suspected pancreatic mass. Ninety-four patients (41 women, 53 men; age range 32-87 years) with a suspected pancreatic tumor underwent preoperative staging with MRI on a 1.5-T system. The MRI protocol included breath-hold MR cholangiopancreatography in turbo spin-echo technique, biphasic contrast-enhanced 3D MR angiography, and MRI of the upper abdomen with breath-hold T2-weighted half-Fourier acquired single-shot turbo spin-echo and T1-weighted fast-low-angle-shot (pre- and postcontrast) sequences. Data were collected prospectively and analyzed by two radiologists in agreement modality. Evaluation criteria were vascular involvement, resectability, and a characterization benign vs malignant. Results were compared to histopathology in 78 patients. Sixteen patients were followed-up. In 74 of 94 patients a solid tumor or an inflammation of the pancreas (n=62) or the papilla (n=12) was detected. In this group, MRI had a sensitivity of 98%, a specificity of 92%, and an accuracy of 96% in the characterization of malignant tumors. Regarding only the solid tumors, the positive predictive value of MRI was 87% with respect to resectability. Other pathologic findings included adenoma or inflammation of the duodenum (n=5), carcinoma or benign stenosis of the choledochus duct (n=7) and carcinoma of the gall bladder (n=2). In 6 patients MRI did not depict any pathologic findings, and follow-up confirmed this interpretation. Magnetic resonance imaging allows a local preoperative staging in patients with suspected pancreatic tumor. Limitations, however, concern to the diagnostics of peritoneal and/or liver metastases. (orig.)

  6. An unusual case of prolonged post-endoscopic retrograde cholangiopancreatography jaundice.

    Science.gov (United States)

    Tziatzios, Georgios; Gkolfakis, Paraskevas; Papanikolaou, Ioannis S; Dimitriadis, George; Triantafyllou, Konstantinos

    2016-04-01

    Despite the effectiveness of endoscopic retrograde cholangiopancreatography (ERCP) for the treatment of choledocholithiasis, various complications have been described. We herein report the first case of prolonged post-ERCP jaundice due to toxicity of the contrast agent Iobitridol (®XENETIX, Guerbet, Roissy CdG Cedex, France) in a patient who underwent ERCP with sphincterectomy and common bile duct stone removal. While clinical improvement and normalization of aminotransferases and cholestatic enzymes after the procedure, an unexplained increase of direct bilirubin was noticed. A second ERCP was performed one week later, excluding possible remaining choledocholithiasis. Nevertheless, serum direct bilirubin increased further up to 15 mg/dL. Other potential causes of direct hyperbilirubinemia were ruled out and patient's liver biopsy was compatible with drug-induced liver toxicity. Additionally, the cause-result time connection between the use of Iobitridol and bilirubin increase indicated the possibility of a toxic effect related to the repeated use of the particular contrast agent. Iobitridol, a contrast agent, can induce prolonged direct hyperbilirubinemia.

  7. Multiple half-second acquisition method of the moving knee joint. Kinematic MR imaging of the anterior cruciate ligament

    Energy Technology Data Exchange (ETDEWEB)

    Niitsu, Mamoru; Ikeda, Kotaroh; Fukubayashi, Tohru; Echigo, Junko; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    1996-10-01

    The objective of this study was to delineate the moving anterior cruciate ligament (ACL) with multiple rapid magnetic resonance (MR) imaging. Rapid gradient echo MR images with an one-shot acquisition time of a half-second were accomplished by short repetition time and phase encoding reduction. Using a mobile knee brace and a flexible surface coil, half-second acquisitions were sequentially acquired during active, constant knee movement. Sixteen knees with intact ACLs and 27 knees with arthroscopically proven ACL tears were examined. Normal ACLs were identified as moving linear low-intensities. The ligaments were readily identified as straight or minimally curved structures when the knee was in semi-flexion compared to the knee extension. Torn ACLs were demonstrated as moving fragments or an amorphous configuration. Intermittent appearances of joint fluid interrupted the ligamentous continuities. Compared to the static images, no significant superiority of the kinematic imaging was found in diagnosis of ACL tears. However, this instant kinematic imaging is feasible with a standard MR system and can provide morphological information for functional analysis of the knee. (author)

  8. A colangiopancreatografia retrógrada endoscópica pode ser realizada com segurança em caráter ambulatorial Safety of endoscopic retrograde cholangiopancreatography performed in ambulatory centers

    Directory of Open Access Journals (Sweden)

    Mara Virginia Lellis Marçal

    2005-03-01

    á evolução nos pacientes inicialmente liberados, confirmando a segurança na realização da colangiopancreatografia endoscópica retrógrada em ambulatório.BACKGROUND: Endoscopic retrograde cholangiopancreatography is effective technique to approach various biliary and pancreatic disorders. Safety of endoscopic retrograde cholangiopancreatography on an outpatient basis has been questioned. OBJECTIVES: To evaluate the safety of outpatient endoscopic retrograde cholangiopancreatography and describe procedure complications. PATIENTS/METHOD: We prospectively assessed outpatients endoscopic retrograde cholangiopancreatography during 2001 to 2003 period. Complications were defined according to consensus criteria and all adverse effects related to procedure were included. RESULTS: One hundred and ninety five outpatients endoscopic retrograde cholangiopancreatography were performed, 79 (40.5% diagnostic and 116 (59.5% therapeutic. The study group included 112 women, mean age 51 (± 18.9 years. The most common diagnoses were: biliary calculi (30.2%, benign stenosis, (13.8%, malignant obstruction (10.2% and chronic pancreatitis (10.2%. Success was achieved in 88.6% of diagnostic endoscopic retrograde cholangiopancreatography and 78.5% in therapeutic. Complications necessitating observation developed in 10 (5.1% of 195 endoscopic retrograde cholangiopancreatography, among them, 7 (3.6% were hospitalized, (2 acute pancreatitis, 2 perforations, 1 bleeding, 1 cardio-respiratory e 1 fever. Among 188 patients initially discharged 8 (4.2% needed readmission (1 acute pancreatitis, 1 bleeding, 1 perforation, 3 cholangitis, 2 abdominal pain. Comparing the first group where complications were immediately identified to the second, no significant statistical difference concerning to age, sex, diagnoses and procedure difficulty degree was found. CONCLUSION: Sample size and negative statistical results failed to determinate independent risk factors for outpatients endoscopic retrograde

  9. Single-shot fluctuations in waveguided high-harmonic generation

    NARCIS (Netherlands)

    Goh, S.J.; Tao, Y.; van der Slot, Petrus J.M.; Bastiaens, Hubertus M.J.; Herek, Jennifer Lynn; Biedron, S.G.; Danailov, M.B.; Milton, S.V.; Boller, Klaus J.

    2015-01-01

    For exploring the application potential of coherent soft x-ray (SXR) and extreme ultraviolet radiation (XUV) provided by high-harmonic generation, it is important to characterize the central output parameters. Of specific importance are pulse-to-pulse (shot-to-shot) fluctuations of the high-harmonic

  10. Villous adenoma of the common hepatic duct: the importance of contrast-enhanced ultrasound and endoscopic retrograde cholangiopancreatography for relevant diagnosis. A case report and review of the literature.

    Science.gov (United States)

    Tefas, Cristian; Tanţău, Marcel; Szenftleben, Alexandru; Chiorean, Liliana; Badea, Radu

    2015-12-01

    Adenomas are frequently encountered in the lower digestive tract but are rarely diagnosed in the biliary tree. We report a case of villous adenoma of the common hepatic duct. A 58-year old male was admitted with a four week history of intermittent upper right quadrant pain. Gray scale and contrast-enhanced abdominal ultrasound showed a mass inside the common hepatic duct with arterial enhancement and slow wash-out during the late venous phase. Subsequent endoscopic retrograde cholangiopancreatography and intraductal ultrasound confirmed the presence of the lesion. The final histopathological examination showed villous adenoma of the common hepatic duct with high-grade dysplasia. Contrast enhanced ultrasonography used in conjecture with endoscopic retrograde cholangiopancreatography can help in differentiating biliary tumors.

  11. Entrance, exit, and reentrance of one shot with a shotgun

    DEFF Research Database (Denmark)

    Gulmann, C; Hougen, H P

    1999-01-01

    The case being reported is one of a homicidal shotgun fatality with an unusual wound pattern. A 34-year-old man was shot at close range with a 12-gauge shotgun armed with No. 5 birdshot ammunition. The shot entered the left axillary region, exited through the left infraclavicular region, and ther......The case being reported is one of a homicidal shotgun fatality with an unusual wound pattern. A 34-year-old man was shot at close range with a 12-gauge shotgun armed with No. 5 birdshot ammunition. The shot entered the left axillary region, exited through the left infraclavicular region...

  12. Effect of shot peening on metastable austenitic stainless steels

    Energy Technology Data Exchange (ETDEWEB)

    Fargas, G., E-mail: gemma.fargas@upc.edu [CIEFMA - Departament de Ciència dels Materials i Enginyeria Metallúrgica, Universitat Politècnica de Catalunya, 08028 Barcelona (Spain); CRnE, Centre de Recerca en Nanoenginyeria, Universitat Politècnica de Catalunya, 08028 Barcelona (Spain); Roa, J.J.; Mateo, A. [CIEFMA - Departament de Ciència dels Materials i Enginyeria Metallúrgica, Universitat Politècnica de Catalunya, 08028 Barcelona (Spain); CRnE, Centre de Recerca en Nanoenginyeria, Universitat Politècnica de Catalunya, 08028 Barcelona (Spain)

    2015-08-12

    In this work, shot peening was performed in a metastable austenitic stainless steel EN 1.4318 (AISI 301LN) in order to evaluate its effect on austenite to martensite phase transformation and also the influence on the fatigue limit. Two different steel conditions were considered: annealed, i.e., with a fully austenitic microstructure, and cold rolled, consisting of a mixture of austenite and martensite. X-ray diffraction, electron back-scattered diffraction and focus ion beam, as well as nanoindentation techniques, were used to elucidate deformation mechanisms activated during shot peening and correlate with fatigue response. Results pointed out that extensive plastic deformation and phase transformation developed in annealed specimens as a consequence of shot peening. However, the increase of roughness and the generation of microcracks led to a limited fatigue limit improvement. In contrast, shot peened cold rolled specimens exhibited enhanced fatigue limit. In the latter case, the main factor that determined the influence on the fatigue response was the distance from the injector, followed successively by the exit speed of the shots and the coverage factor.

  13. Detection of peritoneal dissemination in gynecological malignancy: evaluation by diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Fujii, Shinya; Matsusue, Eiji; Kanasaki, Yoshiko; Nakanishi, Junko; Sugihara, Shuji; Ogawa, Toshihide; Kanamori, Yasunobu; Kigawa, Junzo; Terakawa, Naoki

    2008-01-01

    The aim of this study is to evaluate the usefulness of diffusion-weighted (DW) magnetic resonance (MR) imaging in detecting peritoneal dissemination in cases of gynecological malignancy. We retrospectively analyzed MR images obtained from 26 consecutive patients with gynecological malignancy. Peritoneal dissemination was histologically diagnosed in 15 of the 26 patients after surgery. We obtained DW images and half-Fourier single-shot turbo-spin-echo images in the abdomen and pelvis, and then generated fusion images. Coronal maximum-intensity-projection images were reconstructed from the axial source images. Reader interpretations were compared with the laparotomy findings in the surgical records. Receiver-operating characteristic (ROC) curves were used to represent the presence of peritoneal dissemination. In addition, the sensitivity and specificity were calculated. DW imaging depicted the tumors in 14 of 15 patients with peritoneal dissemination as abnormal signal intensity. ROC analysis yielded Az values of 0.974 and 0.932 for the two reviewers. The mean sensitivity and specificity were 90 and 95.5%. DW imaging plays an important role in the diagnosis and therapeutic management of patients with gynecological malignancy. (orig.)

  14. Kids Guide to Shots

    Science.gov (United States)

    ... First Aid & Safety Doctors & Hospitals Videos Recipes for Kids Kids site Sitio para niños How the Body ... Safe Videos for Educators Search English Español A Kid's Guide to Shots KidsHealth / For Kids / A Kid's ...

  15. [Obstructive cholangiopathy: are endoscopic retrograde cholangiopancreatography and papillotomy always really necessary?].

    Science.gov (United States)

    Pierie, J P; van Vroonhoven, T J

    1999-07-17

    In two women aged 76 and 29 years, who presented with cholangitis and small ductus choledochus calculi and with painless icterus respectively, endoscopic retrograde cholangiopancreatography (ERCP) was carried out with papillotomy. Both developed a duodenal perforation which, however, could not be localized. The first patient eventually died, the second recovered after prolonged hospitalization. A third patient, a 53-year-old man, developed abdominal pain and fever four days after laparoscopic cholecystectomy. ERCP was planned, but in the meantime the patient showed signs of recovery. The ERCP was carried out nevertheless. It failed and the patient suffered a prolonged recovery with necrotizing pancreatitis and multiple operations necessitating a temporary colostoma. In all three patients the endoscopic procedure was performed routinely without strict individualized indication. ERCP and papillotomy may be relatively safe procedures, but it should always be considered whether they will really serve the patient.

  16. Numerical investigation of a shot peening process by a finite element approach

    DEFF Research Database (Denmark)

    Liu, Hongsheng; Zhang, Xiaodan; Hansen, Niels

    2014-01-01

    Shot peening is a surface impact treatment widely used to improve the performance of a metal or a component. The better performance of the shot peened part is controlled by compressive residual stresses resulting from the plastic deformation of the surface layers by impacts of shot. The compressive...... residual stress is generally measured by X-ray diffraction. However, considerable cost and time are needed for such measurements. For this reason, in this work a 3D finite element (FE) model is introduced for a shot peening process. Through the FE simulations, the effect of process parameters...... such as damping ratio of material, friction coefficient, shot velocity and shot angle on the magnitude and distribution of the compressive residual stress is examined....

  17. Investigations of shot reproducibility for the SMP diode at 4.5 MV.

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, Nichelle [National Security Technologies, LLC, Las Vegas, NV (United States); Crain, Marlon D. [National Security Technologies, LLC, Las Vegas, NV (United States); Droemer, Darryl W. [National Security Technologies, LLC, Las Vegas, NV (United States); Gignac, Raymond Edward [National Security Technologies, LLC, Las Vegas, NV (United States); Lare, Gregory A. [National Security Technologies, LLC, Las Vegas, NV (United States); Molina, Isidro [National Security Technologies, LLC, Las Vegas, NV (United States); Obregon, Rafael [National Security Technologies, LLC, Las Vegas, NV (United States); Smith, Chase C. [National Security Technologies, LLC, Las Vegas, NV (United States); Wilkins, Frank Lee [National Security Technologies, LLC, Las Vegas, NV (United States); Welch, Dale Robert [Voss Scientific, LLC, Albuquerque, NM (United States); Cordova, Steve Ray; Gallegos, M.; Johnston, Mark D.; Kiefer, Mark Linden; Leckbee, Joshua J.; Nielsen, Daniel Scott; Oliver, Bryan Velten; Renk, Timothy Jerome; Romero, Tobias; Webb, Timothy Jay; Ziska, Derek Raymond

    2013-11-01

    In experiments conducted on the RITS-6 accelerator, the SMP diode exhibits sig- ni cant shot-to-shot variability. Speci cally, for identical hardware operated at the same voltage, some shots exhibit a catastrophic drop in diode impedance. A study is underway to identify sources of shot-to-shot variations which correlate with diode impedance collapse. To remove knob emission as a source, only data from a shot series conducted with a 4.5-MV peak voltage are considered. The scope of this report is limited to sources of variability which occur away from the diode, such as power ow emission and trajectory changes, variations in pulsed power, dustbin and transmission line alignment, and di erent knob shapes. We nd no changes in the transmission line hardware, alignment, or hardware preparation methods which correlate with impedance collapse. However, in classifying good versus poor shots, we nd that there is not a continuous spectrum of diode impedance behavior but that the good and poor shots can be grouped into two distinct impedance pro les. This result forms the basis of a follow-on study focusing on the variability resulting from diode physics. 3

  18. MR neurography of ulnar nerve entrapment at the cubital tunnel: a diffusion tensor imaging study

    International Nuclear Information System (INIS)

    Breitenseher, Julia B.; Berzaczy, Dominik; Nemec, Stefan F.; Weber, Michael; Prayer, Daniela; Kasprian, Gregor; Kranz, Gottfried; Sycha, Thomas; Hold, Alina

    2015-01-01

    MR neurography, diffusion tensor imaging (DTI) and tractography at 3 Tesla were evaluated for the assessment of patients with ulnar neuropathy at the elbow (UNE). Axial T2-weighted and single-shot DTI sequences (16 gradient encoding directions) were acquired, covering the cubital tunnel of 46 patients with clinically and electrodiagnostically confirmed UNE and 20 healthy controls. Cross-sectional area (CSA) was measured at the retrocondylar sulcus and FA and ADC values on each section along the ulnar nerve. Three-dimensional nerve tractography and T2-weighted neurography results were independently assessed by two raters. Patients showed a significant reduction of ulnar nerve FA values at the retrocondylar sulcus (p = 0.002) and the deep flexor fascia (p = 0.005). At tractography, a complete or partial discontinuity of the ulnar nerve was found in 26/40 (65 %) of patients. Assessment of T2 neurography was most sensitive in detecting UNE (sensitivity, 91 %; specificity, 79 %), followed by tractography (88 %/69 %). CSA and FA measurements were less effective in detecting UNE. T2-weighted neurography remains the most sensitive MR technique in the imaging evaluation of clinically manifest UNE. DTI-based neurography at 3 Tesla supports the MR imaging assessment of UNE patients by adding quantitative and 3D imaging data. (orig.)

  19. MR neurography of ulnar nerve entrapment at the cubital tunnel: a diffusion tensor imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Breitenseher, Julia B.; Berzaczy, Dominik; Nemec, Stefan F.; Weber, Michael; Prayer, Daniela; Kasprian, Gregor [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Kranz, Gottfried; Sycha, Thomas [Medical University of Vienna, Department of Neurology, Vienna (Austria); Hold, Alina [Medical University of Vienna, Department of Plastic and Reconstructive Surgery, Vienna (Austria)

    2015-07-15

    MR neurography, diffusion tensor imaging (DTI) and tractography at 3 Tesla were evaluated for the assessment of patients with ulnar neuropathy at the elbow (UNE). Axial T2-weighted and single-shot DTI sequences (16 gradient encoding directions) were acquired, covering the cubital tunnel of 46 patients with clinically and electrodiagnostically confirmed UNE and 20 healthy controls. Cross-sectional area (CSA) was measured at the retrocondylar sulcus and FA and ADC values on each section along the ulnar nerve. Three-dimensional nerve tractography and T2-weighted neurography results were independently assessed by two raters. Patients showed a significant reduction of ulnar nerve FA values at the retrocondylar sulcus (p = 0.002) and the deep flexor fascia (p = 0.005). At tractography, a complete or partial discontinuity of the ulnar nerve was found in 26/40 (65 %) of patients. Assessment of T2 neurography was most sensitive in detecting UNE (sensitivity, 91 %; specificity, 79 %), followed by tractography (88 %/69 %). CSA and FA measurements were less effective in detecting UNE. T2-weighted neurography remains the most sensitive MR technique in the imaging evaluation of clinically manifest UNE. DTI-based neurography at 3 Tesla supports the MR imaging assessment of UNE patients by adding quantitative and 3D imaging data. (orig.)

  20. SunShot Vision Study: February 2012 (Book)

    Energy Technology Data Exchange (ETDEWEB)

    2012-02-01

    The objective of the SunShot Vision Study is to provide an in-depth assessment of the potential for solar technologies to meet a significant share of electricity demand in the United States during the next several decades. Specifically, it explores a future in which the price of solar technologies declines by about 75% between 2010 and 2020 - in line with the U.S. Department of Energy (DOE) SunShot Initiative's targets.

  1. Improvement of Surface Layer Characteristics by Shot Lining

    Science.gov (United States)

    Harada, Yasunori

    In the present study, lining of the metal with foils using shot peening was investigated to improve the surface layer characteristics. In the shot peening experiment, the foils set on the metal are pelted with hard particles traveling at a high velocity. The foils are bonded to the metal surface due to plastic deformation induced by the collision of the particles. The foils and the metal are heated to heighten the bondability because of the reduction of flow stress. Lining the metal with the hard powder sandwiched between two aluminum foil sheets was also attempted. In this experiment, a centrifugal shot peening machine wite an electrical heater was employed. The metals are commercially aluminium alloys and magnesium alloys, and the foils are commercially aluminum, titanium and nickel. The effects of shot speed and the heating temperature on the bondability were examined. Wear resistance was also evaluated by grinding. The foils were successfully bonded to the metal surface. It was found that the present method is effective in improving of surface layer characteristics.

  2. Get Your Flu Shot!| NIH MedlinePlus the Magazine

    Science.gov (United States)

    ... of this page please turn Javascript on. Feature: Flu Shot Get Your Flu Shot! Past Issues / Winter 2011 Table of Contents ... failure, or lung disease "For the 2010–2011 flu season, the flu vaccine provides protection against the ...

  3. The Effect of Multiple Shot Peening on the Corrosion Behavior of Duplex Stainless Steel

    Science.gov (United States)

    Feng, Qiang; She, Jia; Wu, Xueyan; Wang, Chengxi; Jiang, Chuanhai

    2018-03-01

    Various types of shot peening treatments were applied to duplex stainless steel. The effects of shot peening intensity and working procedures on the microstructure were investigated. The domain size and microstrain evolution in the surface layer were characterized utilizing the Rietveld method. As the shot peening intensity increased, the surface roughness increased in the surface layer; however, it decreased after multiple (dual and triple) shot peening. The mole fraction of strain-induced martensite as a function of the intensity of shot peening was evaluated by XRD measurements. Both potentiodynamic polarization curves and salt spray tests of shot-peened samples in NaCl solution were investigated. The results indicate that traditional shot peening has negative effects on corrosion resistance with increasing shot peening intensity; however, the corrosion rate can be reduced by means of multiple shot peening.

  4. Flu shots and the characteristics of unvaccinated elderly Medicare beneficiaries.

    Science.gov (United States)

    Lochner, Kimberly A; Wynne, Marc

    2011-12-21

    Data from the Medicare Current Beneficiary Survey, 2009. • Overall, 73% of Medicare beneficiaries aged 65 years and older reported receiving a flu shot for the 2008 flu season, but vaccination rates varied by socio-demographic characteristics. Flu vaccination was lowest for beneficiaries aged 65-74 years old, who were non-Hispanic Blacks and Hispanics, were not married, had less than a high school education, or who were eligible for Medicaid (i.e., dual eligibles). • Healthcare utilization and personal health behavior were also related to vaccination rates, with current smokers and those with no hospitalizations or physician visits being less likely to be vaccinated. • Among those beneficiaries who reported receiving a flu shot, 59% received it in a physician's office or clinic, with the next most common setting being in the community (21%); e.g., grocery store, shopping mall, library, or church. • Among those beneficiaries who did not receive a flu shot, the most common reasons were beliefs that the shot could cause side effects or disease (20%), that they didn't think the shot could prevent the flu (17%), or that the shot wasn't needed (16%). Less than 1% reported that they didn't get the flu shot because of cost. Elderly persons (aged 65 years and older) are at increased risk of complications from influenza, with the majority of influenza-related hospitalizations and deaths occurring among the elderly (Fiore et al., 2010). Most physicians recommend their elderly patients get a flu shot each year, and many hospitals inquire about elderly patient's immunization status upon admission, providing a vaccination if requested. The importance of getting a flu shot is underscored by the Department of Health and Human Services' Healthy People initiative, which has set a vaccination goal of 90% for the Nation's elderly by the year 2020 (Department of Health and Human Services [DHHS], 2011). Although all costs related to flu shots are covered by Medicare, requiring

  5. Mumps and the Vaccine (Shot) to Prevent It

    Science.gov (United States)

    ... as measles and rubella. Prevents your child from getting a fever and swollen glands under the ears or jaw from mumps. Keeps your child from missing school or child care (and keeps you from missing work to care for your sick child). Is the MMR shot safe? Yes. The MMR shot is very safe, and it ...

  6. Kinematic Differences between Set- and Jump-Shot Motions in Basketball

    Directory of Open Access Journals (Sweden)

    Hiroki Okubo

    2018-02-01

    Full Text Available Shooting arm motions at release in one-hand set and jump basketball shots have been analyzed using a kinematic model. Set and jump shots are classified by the vertical velocity and acceleration of the shooter’s shooting-side shoulder at release. The two-dimensional three-segment model includes the vertical shooting-side shoulder velocity and acceleration. Numerical simulation investigates the effect of shoulder motion. Release backspin angular velocity can be described as a function of the vertical shoulder acceleration and the vertical fingertip acceleration relative to the shoulder. For proper backspin, jump shots require large vertical fingertip acceleration relative to the shoulder. The upward shoulder speed at release contributes to the vertical fingertip velocity relative to the shoulder for a given desired ball release speed, angle and backspin. On the other hand, upward shoulder motion does not contribute to the horizontal direction. As horizontal shot distance increases, upper arm angular speed also increases to produce the ball release conditions. Ball release with upward shoulder speed reduces the magnitudes of the upper arm, forearm and hand angular velocities. All these facts imply that the shooting arm motion in the jump shot is different from that of the set shot.

  7. A shot parameter specification subsystem for automated control of PBFA II accelerator shots

    International Nuclear Information System (INIS)

    Spiller, J.L.

    1987-01-01

    The author reports on the shot parameter specification subsystem (SPSS), an integral part of the automatic control system developed for the Particle Beam Fusion Accelerator II (PBFA II). This system has been designed to fully utilize the accelerator by tailoring shot parameters to the needs of the experimenters. The SPSS is the key to this flexibility. Automatic systems will be required on many pulsed power machines for the fastest turnaround, the highest reliability, and most cost effective operation. These systems will require the flexibility and the ease of use that is part of the SPSS. The author discusses how the PBFA II control system has proved to be an effective modular system, flexible enough to meet the demands of both the fast track construction of PBFA II and the control needs of Hermes III. This system is expected to meet the demands of most future machine changes

  8. Shot reproducibility of the self-magnetic-pinch diode at 4.5 MV

    OpenAIRE

    Nichelle Bennett; M. Dale Crain; Darryl W. Droemer; Raymond E. Gignac; Greg Lare; Isidro Molina; Robert Obregon; Chase C. Smith; Frank L. Wilkins; Dale R. Welch; Steve Cordova; Manuel L. Gallegos; Mark D. Johnston; Mark L. Kiefer; Joshua J. Leckbee

    2014-01-01

    In experiments conducted at Sandia National Laboratories’ RITS-6 accelerator, the self-magnetic-pinch diode exhibits significant shot-to-shot variability. Specifically, for identical hardware operated at the same voltage, some shots exhibit a catastrophic drop in diode impedance. A study is underway to identify sources of shot-to-shot variations which correlate with diode impedance collapse. The scope of this report is limited to data collected at 4.5-MV peak voltage and sources of variabilit...

  9. An investigation of the properties of conventional and severe shot peened low alloy steel

    Science.gov (United States)

    Quang Trung, Pham; Butler, David Lee; Win Khun, Nay

    2017-07-01

    The effects of the conventional shot peening and severe shot peening process on the mechanical and tribological properties of shot peened AISI 4340 high strength steel were systematically investigated. Compared with the conventional shot peened sample, the ultrafine grain surface layer with a depth of about 20 µm generated by the severe shot peening process can enhance the hardness and wear resistance of the treated material. However, deeper dimples generated by the high media velocity in the severe shot peening process resulted in a higher surface roughness, which is considered as a side effect of this method reducing the fatigue life of the material. Applying a smaller shot size with an appropriate intensity can be used to peen the severe shot peened samples to not only reduce the surface roughness and friction coefficient but also improve the wear resistance for these samples. This work was presented in the shot peening section during ‘The 30th International Conference on Surface Modification Technologies, 2016, Milan, Italy’ (SMT30, ID 61, entitled ‘Comparison of the effects of conventional shot peening and severe shot peening processes on the mechanical and tribological properties of shot peened AISI 4340’) and the authors were encouraged to submit a manuscript to the Materials Research Express journal after adding some nessesary information.

  10. Solitary Fibrous Tumor of the Pancreas: Imaging Findings

    International Nuclear Information System (INIS)

    Kwon, Heon Ju; Byun, Jae Ho; Kang, Jun; Park, Seong Ho; Lee, Moon Gyu

    2008-01-01

    We report here a case of a pathologically proven solitary fibrous tumor of the pancreas. A 54-year-old man was referred to our hospital for further evaluation of a pancreatic mass that was found incidentally. CT, MR imaging, and endoscopic ultrasonography showed a well-defined, enhancing mass with cystic portions of the pancreas body. MR cholangiopancreatography showed no pancreatic duct dilatation. A solitary fibrous tumor of the pancreas is a very rare lesion

  11. Efficiency of the confocal method of laser endomicroscopy in complex diagnoses of diseases of common bile duct

    International Nuclear Information System (INIS)

    Anaskin, S G; Korniletsky, I D; Panchenkov, D N; Chertyuk, V B; Sazonov, D V; Zabozlayev, F G; Danilevskaya, O V; Mokshina, N V

    2017-01-01

    One of the more frequent manifestations of diseases of the bile ducts are its’ strictures or stenoses that could be of either malignant or benign nature. Current methods of diagnosing this pathology include computer tomography (CT) scan, magnetic resonance cholangiopancreatography (MRCP), endoscopic ultrasound (EUS) and endoscopic retrograde cholangiopancreatography (ERCP). However, these methods are not always informative, which makes this a current and topical problem. A fundamentally new method that broadens the capabilities of ERCP when diagnosing diseases of the bile duct accompanied by the development of strictures or stenoses is probe-based confocal laser endomicroscopy (pCLE). The method is based on the principle of confocal fluorescence microscopy. The most elaborate complications arise with the presence of the pre-existing pancreatobiliary pathology: pseudotumoral chronic pancreatitis, acute cholangitis, etc. Early stage cholangiocarcinoma diagnosis can be difficult (and not always possible) even with the help of modern research methods. For the timely diagnostic it is advantageous to conduct pCLE and targeted biopsy of the zone with most manifested changes. In all instances, the first use of the pCLE method for diagnostic purposes allowed us to clarify and correctly verify the diagnosis. When concerning the diseases of the bile duct, the modern stage of pCLE development can be of critical importance when other methods are not effective. (paper)

  12. MR imaging of the temporomandibular joint. Part 2. Effect of flip angle on MR imaging with FLASH sequence

    International Nuclear Information System (INIS)

    Sakamoto, Maya; Sasano, Takashi; Higano, Shuichi; Takahashi, Shoki; Kurihara, Noriko

    1998-01-01

    In our previous study on MR imaging of the temporomandibular joint (TMJ), fast low angle shot (FLASH) showed the highest image contrast between disc and surrounding TMJ tissues compared with those of 4 other sequences (i,e., fast imaging with steady precession (FISP), conventional T1-weighted spin echo (SE) and fast spin echo (FSE, TR/TE/ETL: 1100/12/3, 3000/15/7)). Furthermore, FLASH also received a high score on visual evaluation including the position and contour of the disc, and the border between the disc and surrounding tissues. Therefore, we concluded that FLASH was the most suitable sequence for evaluating the TMJ disc. However, the image contrast and signal intensity on MR imaging with gradient echo pulse sequence are affected by flip angle. Consequently, in this report, to find the most suitable flip angle for MR scanning of the TMJ using a FLASH sequence (TR/TE: 450/11), ten TMJs of 5 volunteers were experimentally imaged with various flip angles from 10 degrees to 70 degrees at an interval of 10 degrees between 10 to 70. The image contrast and contrast-to-noise ratio (CNR) between the disc and surrounding tissues were compared. In addition, signal-to-noise ratio (SNR) of phantoms was also calculated using the same imaging parameters. Visual evaluation including position and contour of the disc, and the border between the disc and surrounding tissues, was also performed by 4 radiologists. As the flip angle increased, imaging contrast decreased while SNR increased. Images with flip angles between 30 and 60 degrees demonstrated high CNR. On visual evaluation, images using flip angles between 30 and 50 degrees received high scores. In conclusion, FLASH sequence with a flip angle between 30 and 50 degrees was considered most suitable for evaluating the TMJ disc based on the results of visual assessment and analysis of three major components of image diagnostic quality: image contrast, CNR and SNR. (author)

  13. Improved MR imaging evaluation of chondromalacia patellae with use of a vise for cartilage compression

    International Nuclear Information System (INIS)

    Koenig, H.; Dinkelaker, F.; Wolf, K.J.

    1990-01-01

    This paper reports on earlier and more precise evaluation of chondromalacia patellae by means of MR imaging performed with a specially constructed vise for compression of the retropatellar cartilage. Two volunteers and 18 patients were examined 1-4 weeks before arthroscopy and cartilage biopsy. Imaging parameters included spin-echo (SE) (1,600/22 + 110 msec) and fast low-angle shot (FLASH) (30/12 msec, 10 degrees and 30 degrees excitation angles) sequences, 4-mm section thickness, and sagittal and axial views. For cartilage compression, we used a wooden vise. FLASH imaging was done without and with compression of the retropatellar cartilage. Cartilage thickness and signal intensities were measured

  14. Shot loading platform analysis

    International Nuclear Information System (INIS)

    Norman, B.F.

    1994-01-01

    This document provides the wind/seismic analysis and evaluation for the shot loading platform. Hand calculations were used for the analysis. AISC and UBC load factors were used in this evaluation. The results show that the actual loads are under the allowable loads and all requirements are met

  15. The effect of mastication on human motor preparation processing: a study with CNV and MRCP.

    Science.gov (United States)

    Sakamoto, Kiwako; Nakata, Hiroki; Honda, Yukiko; Kakigi, Ryusuke

    2009-07-01

    To clarify the effect of mastication on motor preparation processing using electroencephalography (EEG), we investigated the effect of mastication on contingent negative variation (CNV) and reaction time (RT) in Experiment 1, and movement-related cortical potentials (MRCPs) in Experiment 2. The twelve subjects performed four CNV or MRCP sessions, and in the Mastication condition chewed a gum base during the resting period between sessions, Pre (before chewing) and Post 1, 2, and 3 (after chewing). In the Control condition, the subjects performed the same sessions without chewing gum during the intervals between sessions on another day. In Experiment 1, the mean amplitudes of the early- and late-CNV were significantly larger in Mastication than Control at Post 2 and Post 3. RT also differed significantly between Mastication and Control at Post 3. By contrast, in Experiment 2, there were no significant differences between Mastication and Control for the mean amplitudes of MRCPs including Bereitschaftspotential (BP) and negative slope (NS') in any session. These results suggest that mastication influences cognitive processing reflected by CNV with stimulus-triggered movement, rather than motor-related processing reflected by MRCPs relating to self-initiated movement, and provide evidence concerning the mechanisms for the effect of mastication on the human brain.

  16. MR colonography with fecal tagging: comparison between 2D turbo FLASH and 3D FLASH sequences

    International Nuclear Information System (INIS)

    Papanikolaou, Nickolas; Grammatikakis, John; Maris, Thomas; Prassopoulos, Panos; Gourtsoyiannis, Nicholas; Lauenstein, Thomas

    2003-01-01

    The objective of this study was to compare inversion recovery turbo 2D fast low-angle shot (FLASH) and 3D FLASH sequences for fecal-tagged MR colonography studies. Fifteen consecutive patients with indications for colonoscopy underwent MR colonography with fecal tagging. An inversion recovery turbo-FLASH sequence was applied and compared in terms of artifacts presence, efficiency for masking residual stool, and colonic wall conspicuity with a fat-saturated 3D FLASH sequence. Both sequences were acquired following administration of paramagnetic contrast agent. Contrast-to-noise ratio and relative contrast between colonic wall and lumen were calculated and compared for both sequences. Turbo 2D FLASH provided fewer artifacts, higher efficiency for masking the residual stool, and colonic wall conspicuity equivalent to 3D FLASH. An inversion time of 10 ms provided homogeneously low signal intensity of the colonic lumen. Contrast to noise between colonic wall and lumen was significantly higher in the 3D FLASH images, whereas differences in relative contrast were not statistically significant. An optimized inversion-recovery 2D turbo-FLASH sequence provides better fecal tagging results and should be added to the 3D FLASH sequence when designing dark-lumen MR colonography examination protocols. (orig.)

  17. Maximum one-shot dissipated work from Rényi divergences

    Science.gov (United States)

    Yunger Halpern, Nicole; Garner, Andrew J. P.; Dahlsten, Oscar C. O.; Vedral, Vlatko

    2018-05-01

    Thermodynamics describes large-scale, slowly evolving systems. Two modern approaches generalize thermodynamics: fluctuation theorems, which concern finite-time nonequilibrium processes, and one-shot statistical mechanics, which concerns small scales and finite numbers of trials. Combining these approaches, we calculate a one-shot analog of the average dissipated work defined in fluctuation contexts: the cost of performing a protocol in finite time instead of quasistatically. The average dissipated work has been shown to be proportional to a relative entropy between phase-space densities, to a relative entropy between quantum states, and to a relative entropy between probability distributions over possible values of work. We derive one-shot analogs of all three equations, demonstrating that the order-infinity Rényi divergence is proportional to the maximum possible dissipated work in each case. These one-shot analogs of fluctuation-theorem results contribute to the unification of these two toolkits for small-scale, nonequilibrium statistical physics.

  18. Effects of single antegrade hot shot in comparison with no hot shot administration during coronary artery bypass grafting

    Directory of Open Access Journals (Sweden)

    Pouya Mirmohammadsadeghi

    2015-05-01

    Full Text Available BACKGROUND: Superior results will be achieved from cardiac surgery by minimizing the effect of ischemia/reperfusion injury during cross-clamping of the aorta. Different cardioplegia solutions have been introduced, but the optimum one is still ambiguous. The aim of this study is to determine the effect of single antegrade hot shot terminal warm blood cardioplegia (TWBC on patients who had undergone coronary artery bypass grafting (CABG. METHODS: In total, 2488 patients who had CABG surgery in Sina Hospital, Isfahan, Iran, from 2003 to 2011 were enrolled in this case-control study. They were divided into two groups, those who received cold cardioplegia only and those who received a hot shot following cold cardioplegia. Demographics, and clinical data, such as; premature atrial contraction (PAC arrhythmia, diabetes treatment, and left ventricular ejection fraction (EF, were collected and logistic regression analysis was used to analyze the data. RESULTS: There were significant differences found between subjects receiving antegrade hot shot based on direct current (DC shocks, with regard to; female, EF levels, diabetes treatment (P < 0.050. Those who did not receive the hot shot and were not diabetic received more DC shock (P = 0.019. The prevalence of subjects who did no need DC shock was significantly higher among male subjects who had good EF and acceptable diabetic treatment. Multiple logistic regression showed that PAC arrhythmia did not have a significant effect on receiving DC shock during CAGB [0.84 (0.25, 2.85, (P = 0.780]. Having poor EF increased the risk of receiving DC shock among subjects by 2.81 [(1.69, 4.69, (P ≤ 0.001] (P < 0.001. Among the diabetic subjects, receiving insulin decreased the risk of receiving DC shock by 0.54 (0.29, 0.98 (P = 0.042. CONCLUSION: It was concluded that single antegrade hot shot following cold cardioplegia was not particularly effective in the CABG group. TWBC will decrease the need for DC shock.   

  19. Lichtheim’s Golden shot

    NARCIS (Netherlands)

    Eling, P.A.T.M.

    2011-01-01

    Lichtheim belongs to the ranks of most famous aphasiologists, in particular because of a diagram often referred to as ‘Lichtheim’s House’. His single paper on aphasia has drawn the attention of the aphasiological community for many years and may be considered a golden shot. But it became, to

  20. MR-imaging of anterior tibiotalar impingement syndrome: Agreement, sensitivity and specificity of MR-imaging and indirect MR-arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Haller, Joerg [Department of Radiology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Ludwig Boltzmann Institute for Osteology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Bernt, Reinhard [Department of Radiology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria)]. E-mail: reinhard.bernt@wgkk.sozvers.at; Seeger, Thomas [Department of Trauma Surgery, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Weissenbaeck, Alexander [Department of Trauma Surgery, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Tuechler, Heinrich [Ludwig Boltzmann Institute for Hematology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Resnick, Donald [Department of Radiology, VA Medical Center, UCSD, 3350 La Jolla Village Dr, San Diego, CA 92161 (United States)

    2006-06-15

    Objective: To clarify the role of MR-imaging in the diagnosis of anterior ankle impingement syndromes. Materials and methods: We prospectively examined 51 consecutive patients with chronic ankle pain by MR-imaging. Arthroscopy was performed in 29 patients who previously underwent non-enhanced MR-imaging; in 11 patients, indirect MR-arthrography additionally was performed. MR-examinations were correlated with clinical findings; MR and arthroscopy scores were statistically compared, agreement was measured. Results: Arthroscopy demonstrated granulation tissue in the lateral gutter (38%) and anterior recess (31%), lesions of the anterior tibiofibular (31%) and the anterior talofibular ligament (21%) as well as intraarticular bodies (10%). Stenosing tenosynovitis and a ganglionic cyst were revealed as extraarticular causes for chronic ankle pain by MR-examination (17%). Agreement of MR-imaging and arthroscopy was fair for the anterior talofibular ligament and the anterior joint cavity (kappa 0.40). Major discrepancy was found for non-enhanced MR scans (kappa 0.49) when compared with indirect MR-arthrography (kappa 0.03) in the anterior cavity. The sensitivity for lesions of the anterior talofibular and calcaneofibular ligament and the anterior cavity (0.91-0.87) detected by MR-imaging was superior in comparison to lesions of the anterior tibiofibular ligament and anteromedial cavity (0.50-0.24). Conclusion: MR-imaging provides additional information about the mechanics of chronic ankle impingement rather than an accurate diagnosis of this clinical entity. The method is helpful in differentiating extra- from intra-articular causes of ankle impingement. Indirect MR-arthrography has little or no additional value in patients with ankle impingement syndrome.

  1. MR-imaging of anterior tibiotalar impingement syndrome: Agreement, sensitivity and specificity of MR-imaging and indirect MR-arthrography

    International Nuclear Information System (INIS)

    Haller, Joerg; Bernt, Reinhard; Seeger, Thomas; Weissenbaeck, Alexander; Tuechler, Heinrich; Resnick, Donald

    2006-01-01

    Objective: To clarify the role of MR-imaging in the diagnosis of anterior ankle impingement syndromes. Materials and methods: We prospectively examined 51 consecutive patients with chronic ankle pain by MR-imaging. Arthroscopy was performed in 29 patients who previously underwent non-enhanced MR-imaging; in 11 patients, indirect MR-arthrography additionally was performed. MR-examinations were correlated with clinical findings; MR and arthroscopy scores were statistically compared, agreement was measured. Results: Arthroscopy demonstrated granulation tissue in the lateral gutter (38%) and anterior recess (31%), lesions of the anterior tibiofibular (31%) and the anterior talofibular ligament (21%) as well as intraarticular bodies (10%). Stenosing tenosynovitis and a ganglionic cyst were revealed as extraarticular causes for chronic ankle pain by MR-examination (17%). Agreement of MR-imaging and arthroscopy was fair for the anterior talofibular ligament and the anterior joint cavity (kappa 0.40). Major discrepancy was found for non-enhanced MR scans (kappa 0.49) when compared with indirect MR-arthrography (kappa 0.03) in the anterior cavity. The sensitivity for lesions of the anterior talofibular and calcaneofibular ligament and the anterior cavity (0.91-0.87) detected by MR-imaging was superior in comparison to lesions of the anterior tibiofibular ligament and anteromedial cavity (0.50-0.24). Conclusion: MR-imaging provides additional information about the mechanics of chronic ankle impingement rather than an accurate diagnosis of this clinical entity. The method is helpful in differentiating extra- from intra-articular causes of ankle impingement. Indirect MR-arthrography has little or no additional value in patients with ankle impingement syndrome

  2. MR-fluid yield surface determination in disc-type MR rotary brakes

    International Nuclear Information System (INIS)

    Farjoud, Alireza; Vahdati, Nader; Fah, Yap Fook

    2008-01-01

    Magneto-rheological (MR) fluids are currently attracting a great deal of attention because of their unique rheological behavior. Many devices have been designed using MR fluids, and of potential interest here are disc-type MR rotary brakes. The plug flow region in MR devices is defined as the region where the fluid is not flowing. The plug flow region plays an important role in design and analysis of MR devices. In MR dampers, the damping coefficient is a function of the plug thickness. In MR valves, the plug thickness is used to control the flow rate through, and the pressure drop across, the MR valve. A MR clutch is performing at the highest efficiency when the entire MR gap is the plug region. For an MR rotary brake, the highest restraining torque is obtained when the entire gap is the plug region as far as there are no wall slip effects. In this paper, using the Bercovier and Engelman constitutive model, the MR fluid flow in disc-type MR brakes is modeled to determine the plug flow region. The resulting system of equations is solved numerically. It is shown that the existence of a plug flow region in the brake will affect the control torque ratio. Better estimation of the plug flow region results in better estimation of the viscous torque

  3. Mug shot exposure prior to lineup identification: interference, transference, and commitment effects.

    Science.gov (United States)

    Dysart, J E; Lindsay, R C; Hammond, R; Dupuis, P

    2001-12-01

    The effects of viewing mug shots on subsequent identification performance are as yet unclear. Two experiments used a live staged-crime paradigm to determine if interpolated eyewitness exposure to mug shots caused interference, unconscious transference, or commitment effects influencing subsequent lineup accuracy. Experiment 1 (N = 104) tested interference effects. Similar correct decision rates were obtained for the mug shot and no mug shot groups from both perpetrator-present and absent lineups. Experiment 2 (N = 132) tested for commitment and transference effects. Results showed that the commitment group made significantly more incorrect identifications than either the control or the transference group, which had similar false-identification rates. Commitment effects present a serious threat to identification accuracy from lineups following mug shot searches.

  4. Acceptance test procedure, 241-SY-101/241-C-106 shot loading system

    International Nuclear Information System (INIS)

    Ostrom, M.J.

    1994-01-01

    This Acceptance Test Procedure is for the 241-SY-101/241-C-106 Shot Loading System. The procedure will test the components of the Shot Loading System and its capability of adequately loading shot into the annular space of the Container. The loaded shot will provide shielding as required for transporting and storage of a contaminated pump after removal from the tank. This test serves as verification that the SLS is acceptable for use in the pump removal operations for Tanks 241-SY-101, 241-C-106 and 241-AY-102. The pump removal operation for these three tanks will be performed by two different organizations with different equipment, but the Shot Loading System will be compatible between the two operations

  5. Upper body strength and power are associated with shot speed in men's ice hockey

    Directory of Open Access Journals (Sweden)

    Juraj Bežák

    2017-06-01

    Full Text Available Background: Recent studies that addressed shot speed in ice hockey have focused on the relationship between shot speed and variables such as a player's skills or hockey stick construction and its properties. There has been a lack of evidence that considers the relationship between shot speed and player strength, particularly in players at the same skill level. Objective: The aim of this study was to identify the relationship between maximal puck velocity of two shot types (the wrist shot and the slap shot and players' upper body strength and power. Methods: Twenty male professional and semi-professional ice hockey players (mean age 23.3 ± 2.4 years participated in this study. The puck velocity was measured in five trials of the wrist shot and five trials of the slap shot performed by every subject. All of the shots were performed on ice in a stationary position 11.6 meters in front of an electronic device that measures the speed of the puck. The selected strength and power variables were: muscle power in concentric contraction in the countermovement bench press with 40 kg and 50 kg measured with the FiTRODyne Premium device; bench press one-repetition maximum; and grip strength measured by digital hand dynamometer. Results: The correlations between strength/power variables and the puck velocity in the wrist shot and the slap shot ranged between .29-.72 and .16-.62, respectively. Puck velocities produced by wrist shots showed significant correlations with bench press muscle power with 40 kg (p = .004 and 50 kg (p < .001; and one-repetition maximum in bench press (p = .004. The slap shot puck velocity was significantly associated with bench press muscle power with 40 kg (p = .014 and 50 kg (p = .004. Conclusions: This study provides evidence that there are significant associations between shot speed and upper body strength and power.

  6. Time-resolved single-shot terahertz time-domain spectroscopy for ultrafast irreversible processes

    Science.gov (United States)

    Zhai, Zhao-Hui; Zhong, Sen-Cheng; Li, Jun; Zhu, Li-Guo; Meng, Kun; Li, Jiang; Liu, Qiao; Peng, Qi-Xian; Li, Ze-Ren; Zhao, Jian-Heng

    2016-09-01

    Pulsed terahertz spectroscopy is suitable for spectroscopic diagnostics of ultrafast events. However, the study of irreversible or single shot ultrafast events requires ability to record transient properties at multiple time delays, i.e., time resolved at single shot level, which is not available currently. Here by angular multiplexing use of femtosecond laser pulses, we developed and demonstrated a time resolved, transient terahertz time domain spectroscopy technique, where burst mode THz pulses were generated and then detected in a single shot measurement manner. The burst mode THz pulses contain 2 sub-THz pulses, and the time gap between them is adjustable up to 1 ns with picosecond accuracy, thus it can be used to probe the single shot event at two different time delays. The system can detect the sub-THz pulses at 0.1 THz-2.5 THz range with signal to noise ratio (SNR) of ˜400 and spectrum resolution of 0.05 THz. System design was described here, and optimizations of single shot measurement of THz pulses were discussed in detail. Methods to improve SNR were also discussed in detail. A system application was demonstrated where pulsed THz signals at different time delays of the ultrafast process were successfully acquired within single shot measurement. This time resolved transient terahertz time domain spectroscopy technique provides a new diagnostic tool for irreversible or single shot ultrafast events where dynamic information can be extracted at terahertz range within one-shot experiment.

  7. Detection of common bile duct stones before laparoscopic cholecystectomy. Evaluation with MR cholangiography

    International Nuclear Information System (INIS)

    Boraschi, P.; Gigoni, R.; Falaschi, F.; Braccini, G.; Lamacchia, M.; Rossi, M.

    2002-01-01

    Purpose: To assess the diagnostic value of MR cholangiography (MRC) for detecting common bile duct (CBD) stones in candidates for laparoscopic cholecystectomy (LC). Material and Methods: A series of 95 selected patients with gallstones and suspected CBD lithiasis (abnormal serum liver tests and/or CBD size 6.5 mm at US) were referred to our institution for MRC, before LC. MRC was performed on a 0.5 T magnet through a non-breath-hold, respiratory-triggered, fat-suppressed, thin-slab, heavily T2-weighted fast spin-echo sequence and through a breath-hold, thick-slab, single-shot T2-weighted sequence in the coronal plane. Axial T1- and T2-weighted sequences were first obtained. Two observers in conference reviewed source images and maximum intensity projections to determine the presence or absence of choledocholithiasis. MR findings were compared with endoscopic retrograde cholangiography and intraoperative cholangiography (IOC); IOC was always performed during LC. Results: CBD calculi (single or multiple) were identified in 41 out of 95 patients (43%). Two false-positive and 4 false-negative cases were found on MRC. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of MRC for choledocholithiasis were 90%, 96%, 94%, 95%, and 93%, respectively. Conclusion: MRC is a highly effective diagnostic modality for evaluation of patients with risk factors for CBD stones prior to LC Bile ducts gallbladder calculi stenosis or obstruction MR imaging

  8. Characteristics of magnetically insulated diode in a multi-shot operation

    Energy Technology Data Exchange (ETDEWEB)

    Chishiro, E; Masugata, K; Yatsui, K [Nagaoka Univ. of Technology (Japan). Laboratory of Beam Technology

    1997-12-31

    The beam characteristics in a multi-shot operation were evaluated. The MID utilized in the experiment is a racetrack type diode, where flat anode and cathode electrodes are utilized. On the anode, a polyethylene sheet of 1 mm thickness is attached as an ion source. The MID is successively operated without breaking the vacuum. An ion current density (J{sub i}) of 350 A/cm{sup 2} is observed at the first shot when the diode gap is 5 mm. The value decreases with increasing number of shots and at the 7th shot, J{sub i} is less than 150 A/cm{sup 2}. After 7 shots, the anode surface is inspected and found to be covered with stuck matter of metallic materials such as Zn, Al, Fe, Cu. These materials seem to be produced by the ablation of the MID electrode. By eliminating the stuck matter from the surface, J{sub i} is recovered to the initial value. The decrease in J{sub i} is due to the fact that the anode is covered with the stuck matter, which prevents the growth of anode plasma. (author). 6 figs., 8 refs.

  9. Does Courvoisier's sign stand the test of time?

    International Nuclear Information System (INIS)

    Murphy, K.; McLaughlin, P.; O'Connor, B.R.; Breen, M.; O'Súilleabháin, C.; MacEneaney, P.; Maher, M.M.

    2012-01-01

    Aim: To investigate the validity of Courvoisier's sign, in the age of cross-sectional imaging and image analysis software by objectively measuring gallbladder volumes at magnetic resonance cholangiopancreatography (MRCP) in patients with and without biliary obstruction and to assess whether gallbladder volume is more significantly increased in patients with gallstone-related rather than non-gallstone-related biliary obstruction. Materials and methods: All MCRP investigations that were performed at a tertiary hepatobiliary centre over a 2-year period were analysed. The information recorded included the presence or absence of gallbladder stones as well as the presence and type of common bile duct (CBD) disease. Gallbladder volume was calculated from MRCP studies using image analysis software. Results: Three hundred and ninety-four of 645 examined MRCPs (61.1%) were eligible for analysis. A statistically significant difference in mean gallbladder volume existed between the summated obstructive and non-obstructive groups (p < 0.001). In addition, a significant difference existed in mean gallbladder volume between those with CBD stones and non-gallstone CBD obstruction (p = 0.03). Conclusion: A significant difference was observed in gallbladder volumes in the group with biliary obstruction from choledocholithiasis compared with the group with biliary obstruction from other causes. Thus, objective measurement of gallbladder volume from modern cross-sectional imaging studies appears to validate Courvoisier's sign as a valuable clinical sign, which could be applied to modern imaging studies in distinguishing different causes of biliary obstruction in the jaundiced patient.

  10. Rotary peening with captive shot

    International Nuclear Information System (INIS)

    1998-02-01

    Roto Peen with captive shot removes coatings and surface contamination from concrete floors. The objective of treating radioactively contaminated concrete floors during the Deactivation and Decommissioning (D and D) process is to reduce the surface contamination levels to meet regulatory criteria for unrestricted use. The US Department of Energy (DOE) Chicago Operations office and DOE's Federal Energy Technology Center (FETC) jointly sponsored a Large-Scale Demonstration Project (LSDP) at the Chicago Pile-5 Research Reactor (CP-5) at Argonne National Laboratory-East (ANL). The objective of the LSDP is to demonstrate potentially beneficial D and D technologies in comparison with current baseline technologies. As part of the LSDP, roto Peen with captive shot was demonstrated March 17--20, 1997, to treat a 20 x 25 ft area of radioactively contaminated concrete floor on the service level of the CP-5 building

  11. Networks of ·/G/∞ queues with shot-noise-driven arrival intensities

    NARCIS (Netherlands)

    Koops, D.T.; Boxma, O.J.; Mandjes, M.R.H.

    2017-01-01

    We study infinite-server queues in which the arrival process is a Cox process (or doubly stochastic Poisson process), of which the arrival rate is given by a shot-noise process. A shot-noise rate emerges naturally in cases where the arrival rate tends to exhibit sudden increases (or shots) at random

  12. Synthesis and characterization of magneto-rheological (MR fluids for MR brake application

    Directory of Open Access Journals (Sweden)

    Bhau K. Kumbhar

    2015-09-01

    Full Text Available Magneto rheological (MR fluid technology has been proven for many industrial applications like shock absorbers, actuators, etc. MR fluid is a smart material whose rheological characteristics change rapidly and can be controlled easily in presence of an applied magnetic field. MR brake is a device to transmit torque by the shear stress of MR fluid. However, MR fluids exhibit yield stress of 50–90 kPa. In this research, an effort has been made to synthesize MR fluid sample/s which will typically meet the requirements of MR brake applications. In this study, various electrolytic and carbonyl iron powder based MR fluids have been synthesized by mixing grease as a stabilizer, oleic acid as an antifriction additive and gaur gum powder as a surface coating to reduce agglomeration of the MR fluid. MR fluid samples based on sunflower oil, which is bio-degradable, environmentally friendly and abundantly available have also been synthesized. These MR fluid samples are characterized for determination of magnetic, morphological and rheological properties. This study helps identify most suitable localized MR fluid meant for MR brake application.

  13. Optical properties (bidirectional reflectance distribution function) of shot fabric.

    Science.gov (United States)

    Lu, R; Koenderink, J J; Kappers, A M

    2000-11-01

    To study the optical properties of materials, one needs a complete set of the angular distribution functions of surface scattering from the materials. Here we present a convenient method for collecting a large set of bidirectional reflectance distribution function (BRDF) samples in the hemispherical scattering space. Material samples are wrapped around a right-circular cylinder and irradiated by a parallel light source, and the scattered radiance is collected by a digital camera. We tilted the cylinder around its center to collect the BRDF samples outside the plane of incidence. This method can be used with materials that have isotropic and anisotropic scattering properties. We demonstrate this method in a detailed investigation of shot fabrics. The warps and the fillings of shot fabrics are dyed different colors so that the fabric appears to change color at different viewing angles. These color-changing characteristics are found to be related to the physical and geometrical structure of shot fabric. Our study reveals that the color-changing property of shot fabrics is due mainly to an occlusion effect.

  14. Centrifugal shot blast system

    International Nuclear Information System (INIS)

    1998-02-01

    This report describes a demonstration of Concrete cleaning, Inc., modified centrifugal shot blast technology to remove the paint coating from concrete flooring. This demonstration is part of the Chicago Pile-5 (CP-5) Large-Scale Demonstration Project (LSDP) sponsored by the US Department of Energy (DOE), office of Science and Technology (OST), Deactivation and Decommissioning Focus Area (DDFA). The objective of the LSDP is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East (ANL) CP-5 Research Reactor. The purpose of the LSDP is to demonstrate that using innovative and improved decontamination and decommissioning (D and D) technologies from various sources can result in significant benefits, such as decreased cost and increased health and safety, as compared with baseline D and D technologies. Potential markets exist for the innovative centrifugal shot blast system at the following sites: Fernald Environmental Management Project, Los Alamos, Nevada, Oak Ridge Y-12 and K-25, Paducah, Portsmouth Gaseous Diffusion site, and the Savannah River Site. This information is based on a revision to the OST Linkage Tables dated August 4, 1997

  15. Shot reproducibility of the self-magnetic-pinch diode at 4.5 MV

    Directory of Open Access Journals (Sweden)

    Nichelle Bennett

    2014-05-01

    Full Text Available In experiments conducted at Sandia National Laboratories’ RITS-6 accelerator, the self-magnetic-pinch diode exhibits significant shot-to-shot variability. Specifically, for identical hardware operated at the same voltage, some shots exhibit a catastrophic drop in diode impedance. A study is underway to identify sources of shot-to-shot variations which correlate with diode impedance collapse. The scope of this report is limited to data collected at 4.5-MV peak voltage and sources of variability which occur away from the diode, such as sheath electron emission and trajectories, variations in pulsed power, load and transmission line alignment, and different field shapers. We find no changes in the transmission line hardware, alignment, or hardware preparation methods which correlate with impedance collapse. However, in classifying good versus poor shots, we find that there is not a continuous spectrum of diode impedance behavior but that the good and poor shots can be grouped into two distinct impedance profiles. In poor shots, the sheath current in the load region falls from 16%–30% of the total current to less than 10%. This result will form the basis of a follow-up study focusing on the variability resulting from diode physics.

  16. Location of disease on imaging may predict radiation exposure during endoscopic retrograde cholangiopancreatography

    International Nuclear Information System (INIS)

    Choi, Moon Hyung; Jung, Seung Eun; Yoon, Seung Bae; Lee, In Seokand; Byun, Jae Young

    2017-01-01

    Endoscopic retrograde cholangiopancreatography (ERCP) is performed for various diseases. The aim of this study is to evaluate the difference of dose-area product (DAP) during the ERCP procedures according to location of the lesion. We performed a retrospective study of consecutive 217 therapeutic ERCP examinations performed between November 2014 and April 2015 at a tertiary care center. ERCP procedures divided into two groups according to location of the lesion identified on imaging: lesions in the common hepatic duct (CHD) or the common bile duct (CBD) and lesions in the hepatic hilum or the intrahepatic duct (IHD). The mean DAP of the hilum-IHD group (48.7 Gy cm 2 ) was significantly higher than that of the CBD-CHD group (34.9 Gy cm 2 ) (P = 0.003). Radiation exposure during ERCP was significantly different according to location of bile duct lesion. (authors)

  17. The value of fast MR imaging as an adjunct to ultrasound in prenatal diagnosis

    International Nuclear Information System (INIS)

    Breysem, L.; Bosmans, H.; Dymarkowski, S.; Demaerel, P.; Vanbeckevoort, D.; Smet, M.; Schoubroeck, D.Van; Witters, I.; Deprest, J.; Vanhole, C.; Casaer, P.

    2003-01-01

    The aim of this study was to evaluate the role of MR imaging of the fetus to improve sonographic prenatal diagnosis of congenital anomalies. In 40 fetuses (not consecutive cases) with an abnormality diagnosed with ultrasound, additional MR imaging was performed. The basic sequence was a T2-weighted single-shot half Fourier (HASTE) technique. Head, neck, spinal, thoracic, urogenital, and abdominal fetal pathologies were found. This retrospective, observational study compared MR imaging findings with ultrasonographic findings regarding detection, topography, and etiology of the pathology. The MR findings were evaluated as superior, equal to, or inferior compared with US, in consent with the referring gynecologists. The role of these findings in relation to pregnancy management was studied and compared with postnatal follow-up in 30 of 40 babies. Fetal MRI technique was successful in 36 of 39 examinations and provided additional information in 21 of 40 fetuses (one twin pregnancy with two members to evaluate). More precise anatomy and location of fetal pathology (20 of 40 cases) and additional etiologic information (8 of 40 cases) were substantial advantages in cerebrospinal abnormalities [ventriculomegaly, encephalocele, vein of Galen malformation, callosal malformations, meningo(myelo)cele], in retroperitoneal abnormalities (lymphangioma, renal agenesis, multicystic renal dysplasia), and in neck/thoracic pathology [cervical cystic teratoma, congenital hernia diaphragmatica, congenital cystic adenomatoid lung malformation (CCAM)]. This improved parental counseling and pregnancy management in 15 pregnancies. In 3 cases, prenatal MRI findings did not correlate with prenatal ultrasonographic findings or neonatal diagnosis. The MRI provided a more detailed description and insight into fetal anatomy, pathology, and etiology in the vast majority of these selected cases. This improved prenatal parental counseling and postnatal therapeutic planning. (orig.)

  18. The value of fast MR imaging as an adjunct to ultrasound in prenatal diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Breysem, L.; Bosmans, H.; Dymarkowski, S.; Demaerel, P.; Vanbeckevoort, D.; Smet, M. [Department of Radiology, University Hospitals, Herestraat 49, 3000, Leuven (Belgium); Schoubroeck, D.Van; Witters, I.; Deprest, J. [Department of Obstetrics and Gynecology, University Hospitals, Herestraat 49, 3000, Leuven (Belgium); Vanhole, C.; Casaer, P. [Department of Pediatrics, University Hospitals, Herestraat 49, 3000, Leuven (Belgium)

    2003-07-01

    The aim of this study was to evaluate the role of MR imaging of the fetus to improve sonographic prenatal diagnosis of congenital anomalies. In 40 fetuses (not consecutive cases) with an abnormality diagnosed with ultrasound, additional MR imaging was performed. The basic sequence was a T2-weighted single-shot half Fourier (HASTE) technique. Head, neck, spinal, thoracic, urogenital, and abdominal fetal pathologies were found. This retrospective, observational study compared MR imaging findings with ultrasonographic findings regarding detection, topography, and etiology of the pathology. The MR findings were evaluated as superior, equal to, or inferior compared with US, in consent with the referring gynecologists. The role of these findings in relation to pregnancy management was studied and compared with postnatal follow-up in 30 of 40 babies. Fetal MRI technique was successful in 36 of 39 examinations and provided additional information in 21 of 40 fetuses (one twin pregnancy with two members to evaluate). More precise anatomy and location of fetal pathology (20 of 40 cases) and additional etiologic information (8 of 40 cases) were substantial advantages in cerebrospinal abnormalities [ventriculomegaly, encephalocele, vein of Galen malformation, callosal malformations, meningo(myelo)cele], in retroperitoneal abnormalities (lymphangioma, renal agenesis, multicystic renal dysplasia), and in neck/thoracic pathology [cervical cystic teratoma, congenital hernia diaphragmatica, congenital cystic adenomatoid lung malformation (CCAM)]. This improved parental counseling and pregnancy management in 15 pregnancies. In 3 cases, prenatal MRI findings did not correlate with prenatal ultrasonographic findings or neonatal diagnosis. The MRI provided a more detailed description and insight into fetal anatomy, pathology, and etiology in the vast majority of these selected cases. This improved prenatal parental counseling and postnatal therapeutic planning. (orig.)

  19. The wear and corrosion resistance of shot peened-nitrided 316L austenitic stainless steel

    International Nuclear Information System (INIS)

    Hashemi, B.; Rezaee Yazdi, M.; Azar, V.

    2011-01-01

    Research highlights: → Shot peening-nitriding increased the wear resistance and surface hardness of samples. → This treatment improved the surface mechanical properties. → Shot peening alleviates the adverse effects of nitriding on the corrosion behavior. -- Abstract: 316L austenitic stainless steel was gas nitrided at 570 o C with pre-shot peening. Shot peening and nitriding are surface treatments that enhance the mechanical properties of surface layers by inducing compressive residual stresses and formation of hard phases, respectively. The structural phases, micro-hardness, wear behavior and corrosion resistance of specimens were investigated by X-ray diffraction, Vickers micro-hardness, wear testing, scanning electron microscopy and cyclic polarization tests. The effects of shot peening on the nitride layer formation and corrosion resistance of specimens were studied. The results showed that shot peening enhanced the nitride layer formation. The shot peened-nitrided specimens had higher wear resistance and hardness than other specimens. On the other hand, although nitriding deteriorated the corrosion resistance of the specimens, cyclic polarization tests showed that shot peening before the nitriding treatment could alleviate this adverse effect.

  20. Occupational exposure to staff during endoscopic retrograde cholangiopancreatography in Sudan

    International Nuclear Information System (INIS)

    Sulieman, A.; Elzaki, M.; Khalil, M.

    2011-01-01

    Endoscopic retrograde cholangiopancreatography (ERCP) procedure is an invasive technique that requires fluoroscopic and radiographic exposure. The purpose of this study was to determine the occupational dose of ionising radiation at three gastroenterology departments (Fedial, Soba and Ibn seena hospitals) in Khartoum (Sudan). The radiation dose was measured during 55 therapeutic ERCP procedures. Thermoluminescence dosemeters were used. The mean radiation dose for the first operator was 0.27 mGy for the eye lens, 0.21 for the thyroid, 0.32 for the chest, 0.17 for the hand and 0.22 for the leg. The mean radiation dose for the second operator was 0.21 mGy for the hand and 0.20 mGy for the chest, while the mean radiation dose for the nurse was 0.44 mGy for the hand and 0.19 for the chest. The radiation dose received by the staff in these hospitals was found to be higher than most of the values in the literature. The radiation absorbed dose received by the different organs is relatively low. Additional studies need to be conducted for radiation dose optimisation. (authors)

  1. Endoscopic retrograde cholangiopancreatography after Billroth-Ⅱ gastrectomy and its safety

    Directory of Open Access Journals (Sweden)

    LEI Ting

    2016-06-01

    Full Text Available ObjectiveTo investigate the safety of endoscopic retrograde cholangiopancreatography (ERCP after Billroth-Ⅱ gastrectomy. MethodsA total of 43 patients who were admitted to our hospital and underwent Billroth-Ⅱ gastrectomy from June 2012 to June 2015 were enrolled and underwent ERCP. ResultsOf all 43 patients undergoing ERCP, 39 (90.7% received successful intubation, 2 (4.7% received failed intubation, and 2 (47% experienced the complication of digestive tract perforation. Among the 39 patients who underwent ERCP, 31 (79.5% were diagnosed with common bile duct stones (3 underwent sphincterotomy and 28 underwent endoscopic papillary balloon dilation to remove stones, 6 (15.4% were diagnosed with benign stenosis at the end of bile duct (4 underwent papillary balloon dilation alone and 2 underwent biliary plastic stent implantation, and 1 patient each (2.6% was diagnosed with ampullary tumor and hepatic portal metastasis of gastric cancer and received implantation of metal and plastic stents, respectively. One patient (26% experienced acute pancreatitis after surgery. ConclusionERCP is safe and effective in patients after Billroth-Ⅱ gastrectomy and holds promise for clinical application.

  2. ZAPP shot summary

    Energy Technology Data Exchange (ETDEWEB)

    Loisel, Guillaume Pascal [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-10-01

    This was the second Z Astrophysical Plasma Properties (ZAPP) fundamental science shot series of 2015. ZAPP experiments measure fundamental properties of atoms in plasmas to solve the following important astrophysical puzzles: Why can’t we accurately model the opacity of Fe at the convection zone boundary in the Sun? How accurate are the photoionization models used to interpret data from xray satellite observations? and Why doesn’t spectral fitting provide the correct properties for White Dwarfs?

  3. Intra-shot MSE Calibration Technique For LHCD Experiments

    International Nuclear Information System (INIS)

    Ko, Jinseok; Scott, Steve; Shiraiwa, Syun'ichi; Greenwald, Martin; Parker, Ronald; Wallace, Gregory

    2009-01-01

    The spurious drift in pitch angle of order several degrees measured by the Motional Stark Effect (MSE) diagnostic in the Alcator C-Mod tokamak1 over the course of an experimental run day has precluded direct utilization of independent absolute calibrations. Recently, the underlying cause of the drift has been identified as thermal stress-induced birefringence in a set of in-vessel lenses. The shot-to-shot drift can be avoided by using MSE to measure only the change in pitch angle between a reference phase and a phase of physical interest within a single plasma discharge. This intra-shot calibration technique has been applied to the Lower Hybrid Current Drive (LHCD) experiments and the measured current profiles qualitatively demonstrate several predictions of LHCD theory such as an inverse dependence of current drive efficiency on the parallel refractive index and the presence of off-axis current drive.

  4. Value of new MR techniques in MR-PET; Stellenwert neuer MR-Techniken in der MR-PET

    Energy Technology Data Exchange (ETDEWEB)

    Attenberger, U.I.; Schoenberg, S.O. [Universitaetsmedizin Mannheim, Medizinische Fakultaet Mannheim der Universitaet Heidelberg, Institut fuer klinische Radiologie und Nuklearmedizin, Mannheim (Germany); Quick, H.H. [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Institut fuer Medizinische Physik, Erlangen (Germany); Guimaraes, A. [Massachusetts General Hospital, Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown (United States); Catalano, O. [University of Naples Federico II, Naples (Italy); Morelli, J.N. [The Johns Hopkins Hospital, The Russell H. Morgan Department of Radiology and Radiological Science, Baltimore (United States)

    2013-12-15

    The unparalleled soft tissue contrast of magnetic resonance imaging (MRI) and the functional information obtainable with 18-F fluorodeoxyglucose positron emission tomography (FDG-PET) render MR-PET well-suited for oncological and psychiatric imaging. The lack of ionizing radiation with MRI also makes MR-PET a promising modality for oncology patients requiring frequent follow-up and pediatric patients. Lessons learned with PET computed tomography (CT) over the last few years do not directly translate to MR-PET. For example, in PET-CT the Hounsfield units derived from CT are used for attenuation correction (AC). As 511 keV photons emitted in PET examinations are attenuated by the patient's body CT data are converted directly to linear attenuation coefficients (LAC); however, proton density measured by MRI is not directly related to the radiodensity or LACs of biological tissue. Thus, direct conversion to LAC data is not possible making AC more challenging in simultaneous MRI-PET scanning. In addition to these constraints simultaneous MRI-PET acquisitions also improve on some solutions to well-known challenges of hybrid imaging techniques, such as limitations in motion correction. This article reports on initial clinical experiences with simultaneously acquired MRI-PET data, focusing on the potential benefits and limitations of MRI with respect to motion correction as well as metal and attenuation correction artefacts. (orig.) [German] Die klinische Implementierung der neuen Hybridtechnologie MR-Positronenemissionstomographie (MR-PET) bietet durch die Kombination aus hochaufloesender Morphologie, Funktion und Metabolismus bisher ungeahnte diagnostische Moeglichkeiten, die nicht nur fuer die Diagnose und die Verlaufskontrolle onkologischer und psychiatrischer Erkrankungen von hoher Bedeutung sind. Verglichen mit der PET-CT wird dies mit reduzierter Strahlenbelastung fuer den Patienten moeglich, was wiederum insbesondere fuer Patienten in der Tumornachsorge, die

  5. MRI diagnosis and preoperative evaluation for hepatic hilar tumor

    International Nuclear Information System (INIS)

    Liu Yulin; Kong xiangquan; Xu Haibo; Xiao Xuehong; Liu Dingxi; Peng Zhenjun

    2004-01-01

    Objective: To investigate the value of the all-in-one MR scanning in the diagnosis and preoperative evaluation of hepatic hilar tumor. Methods: Forty-two cases of hepatic hilar tumors were examined with a 1.5 T superconductive MR system, including hepatocellular carcinoma (HCC, n=12), hilar cholangiocarcinoma (HC, n=22), and hilar metastasis (n=8). Besides the precontrast MRI and MRCP, all cases underwent consecutive dynamic contrast-enhanced MR scanning. The whole liver dynamic contrast-enhanced MR was performed with the first bolus injection of Gd-DTPA (10 ml), and 15 minutes later, 3D DCE MRA was performed with additional injection of Gd-DTPA (15-20 ml) (0.15-0.20 mmol/kg). The contrast time-signal curve of liver and tumor was drawn, and arterial and portal venous phase images were reconstructed with MIP. MR appearances were compared with surgical findings and pathology. Results: Consecutive DCE scanning was successfully performed in all cases. The contrast time-signal curve of HCC showed type I and II (10/12, 83.3%), and the curve of HC showed type III and IV (21/22, 95.4%), whereas the curve of metastasis was various. The difference of tumor peak transit time (PT) between HCC group and HC group was significant (P<0.05). The vascular invasion in HCC group appeared as arterial-portal vein fistula (2/12, 16.7%), portal vein infiltration (3/24, 12.5%), and occlusion by tumor thrombosis (4/24, 16.7%). However, the vascular invasion in HC group showed spiral artery (5/22, 22.7%), portal vein infiltration (5/44, 11.4%), portal vein central narrowing (8/44, 18.2%) and occlusion (11/44, 25.0%). All metastasis had no vascular invasion expect one gall bladder carcinoma with right portal vein infiltration. The accuracy of preoperative evaluation with MRI in HCC group and HC group was 83.3% (10/12) and 86.4% (19/22), respectively. The accuracy of preoperative evaluation in all hilar tumors was 78.6% (33/42). Conclusion: Consecutive DCE was a safe and useful technique in MR

  6. MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

    Science.gov (United States)

    Fei, Baowei; Yang, Xiaofeng; Nye, Jonathon A.; Aarsvold, John N.; Raghunath, Nivedita; Cervo, Morgan; Stark, Rebecca; Meltzer, Carolyn C.; Votaw, John R.

    2012-01-01

    Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with [11C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR

  7. MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

    Energy Technology Data Exchange (ETDEWEB)

    Fei, Baowei, E-mail: bfei@emory.edu [Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1841 Clifton Road Northeast, Atlanta, Georgia 30329 (United States); Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, Georgia 30322 (United States); Department of Mathematics and Computer Sciences, Emory University, Atlanta, Georgia 30322 (United States); Yang, Xiaofeng; Nye, Jonathon A.; Raghunath, Nivedita; Votaw, John R. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Aarsvold, John N. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Nuclear Medicine Service, Atlanta Veterans Affairs Medical Center, Atlanta, Georgia 30033 (United States); Cervo, Morgan; Stark, Rebecca [The Medical Physics Graduate Program in the George W. Woodruff School, Georgia Institute of Technology, Atlanta, Georgia 30332 (United States); Meltzer, Carolyn C. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Department of Neurology and Department of Psychiatry and Behavior Sciences, Emory University School of Medicine, Atlanta, Georgia 30322 (United States)

    2012-10-15

    Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with [{sup 11}C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR/PET.

  8. MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

    International Nuclear Information System (INIS)

    Fei, Baowei; Yang, Xiaofeng; Nye, Jonathon A.; Raghunath, Nivedita; Votaw, John R.; Aarsvold, John N.; Cervo, Morgan; Stark, Rebecca; Meltzer, Carolyn C.

    2012-01-01

    Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with ["1"1C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR/PET.

  9. The finite element analysis for prediction of residual stresses induced by shot peening

    International Nuclear Information System (INIS)

    Kim, Cheol; Yang, Won Ho; Sung, Ki Deug; Cho, Myoung Rae; Ko, Myung Hoon

    2000-01-01

    The shot peening is largely used for a surface treatment in which small spherical parts called shots are blasted on a surface of a metallic components with velocities up to 100m/s. This treatment leads to an improvement of fatigue behavior due to the developed compressive residual stresses, and so it has gained widespread acceptance in the automobile and aerospace industries. The residual stress profile on surface layer depends on the parameters of shot peening, which are, shot velocity, shot diameter, coverage, impact angle, material properties etc. and the method to confirm this profile is only measurement by X-ray diffractometer. Despite its importance to automobile and aerospace industries, little attention has been devoted to the accurate modeling of the process. In this paper, the simulation technique is applied to predict the magnitude and distribution of the residual stress and plastic deformation caused by shot peening with the help of the finite element analysis

  10. Shot-peening of carbonitrided steel: influence of the process on the mechanical state

    Directory of Open Access Journals (Sweden)

    François M.

    2010-06-01

    Full Text Available Residual stresses have a significant role in affecting engineering properties of materials and shot peening process is an effective production technique to ensure required residual stress levels. This paper presents an analysis of an orthogonal design of experiment to establish an empirical relationship between main parameters of shot peening process and residual stress profiles for a carbonitrided steel. The hardening / softening evolution of the material is followed using hardness and diffraction peak width. Four critical peening parameters, i.e. shot size, incident angle, exposure time, airblast pressure, have been chosen and the range of peening conditions are established by using the Taguchi technique. In this study, a shot velocity measurement system is used to obtain the on-line velocity during the peening process and the relationship between the maximum compressive residual stresses and the shot velocity is also developed. Analysis of the experimental data showed that it is possible to optimize the shot peening process by an effective control of process parameters.

  11. Temperature dependence of shot noise in double barrier magnetic tunnel junctions

    Science.gov (United States)

    Niu, Jiasen; Liu, Liang; Feng, J. F.; Han, X. F.; Coey, J. M. D.; Zhang, X.-G.; Wei, Jian

    2018-03-01

    Shot noise reveals spin dependent transport properties in a magnetic tunnel junction. We report measurement of shot noise in CoFeB/MgO/CoFeB/MgO/CoFeB double barrier magnetic tunnel junctions, which shows a strong temperature dependence. The Fano factor used to characterize shot noise increases with decreasing temperature. A sequential tunneling model can be used to account for these results, in which a larger Fano factor results from larger spin relaxation length at lower temperatures.

  12. Appearances of diffuse excessive high signal intensity (DEHSI) on MR imaging following preterm birth

    International Nuclear Information System (INIS)

    Hart, Anthony R.; Smith, Michael F.; Rigby, Alan S.; Wallis, Lauren I.; Whitby, Elspeth H.

    2010-01-01

    Diffuse damage to the periventricular white matter has recently been suggested to be a cause of the cognitive deficits seen following preterm birth. It is unclear whether this form of injury can be visualised on MR imaging, but one group has described diffuse excessive high signal intensity (DEHSI) as a possible form of diffuse white matter injury. This finding is dependant on window imaging and the subjective assessment of the reviewer, but little data have been published on the degree of subjectivity on its appearance among raters. To assess the subjectivity of DEHSI on conventional and ultrafast T2-weighted MR imaging following preterm birth. An observational study of 40 preterm infants who had MR imaging of the brain around term-equivalent age, including conventional fast spin-echo (FSE) and ultrafast single-shot fast spin-echo (SSFSE) T2-weighted sequences in the axial plane. Images were anonymised and scored twice by four observers for the presence of DEHSI. Inter- and intra-observer agreement were calculated. Sixty-five percent of conventional and 100% of the ultrafast images were of diagnostic quality. DEHSI was noted in between 0% and 69.2% of conventional images and 27.5-90% of the ultrafast images. Inter- and intra-observer agreement ranged from none to moderate. The visual appearances of DEHSI on conventional FSE and ultrafast SSFSE T2-W images are highly subjective, limiting its clinical application. (orig.)

  13. Appearances of diffuse excessive high signal intensity (DEHSI) on MR imaging following preterm birth

    Energy Technology Data Exchange (ETDEWEB)

    Hart, Anthony R. [Sheffield Teaching Hospital NHS Foundation Trust, Department of Neonatology, Jessop Wing, Sheffield (United Kingdom); University of Sheffield, Academic Unit of Radiology, Royal Hallamshire Hospital, Sheffield (United Kingdom); University of Sheffield, Department of Academic Radiology, Royal Hallamshire Hospital, Sheffield (United Kingdom); Smith, Michael F. [Sheffield Teaching Hospital NHS Foundation Trust, Department of Neonatology, Jessop Wing, Sheffield (United Kingdom); Rigby, Alan S. [University of Hull, Postgraduate Medical Centre, Castle Hill Hospital, East Yorkshire (United Kingdom); Wallis, Lauren I.; Whitby, Elspeth H. [University of Sheffield, Academic Unit of Radiology, Royal Hallamshire Hospital, Sheffield (United Kingdom)

    2010-08-15

    Diffuse damage to the periventricular white matter has recently been suggested to be a cause of the cognitive deficits seen following preterm birth. It is unclear whether this form of injury can be visualised on MR imaging, but one group has described diffuse excessive high signal intensity (DEHSI) as a possible form of diffuse white matter injury. This finding is dependant on window imaging and the subjective assessment of the reviewer, but little data have been published on the degree of subjectivity on its appearance among raters. To assess the subjectivity of DEHSI on conventional and ultrafast T2-weighted MR imaging following preterm birth. An observational study of 40 preterm infants who had MR imaging of the brain around term-equivalent age, including conventional fast spin-echo (FSE) and ultrafast single-shot fast spin-echo (SSFSE) T2-weighted sequences in the axial plane. Images were anonymised and scored twice by four observers for the presence of DEHSI. Inter- and intra-observer agreement were calculated. Sixty-five percent of conventional and 100% of the ultrafast images were of diagnostic quality. DEHSI was noted in between 0% and 69.2% of conventional images and 27.5-90% of the ultrafast images. Inter- and intra-observer agreement ranged from none to moderate. The visual appearances of DEHSI on conventional FSE and ultrafast SSFSE T2-W images are highly subjective, limiting its clinical application. (orig.)

  14. Assessment of resectability of pancreatic cancer with dynamic contrast-enhanced MR imaging: technique, surgical correlation and patient outcome

    International Nuclear Information System (INIS)

    Spencer, J.A.; Ward, J.; Guthrie, J.A.; Robinson, P.J.A.; Guillou, P.J.

    1998-01-01

    The aim of our work was to investigate the use of a dynamic contrast-enhanced MR (DCEMR) technique for staging apparently localised pancreatic cancer, and to determine the patterns of tumour and vascular enhancement with this technique. Thirty-five consecutive patients were examined. The MR findings were correlated with surgical findings in 13 patients and with clinical outcome in 22 patients. Breath-hold gradient-echo fast low angle shot (TR = 100, TE = 4, flip angle 80 ) acquisitions were obtained at 10 and 40 s (right anterior coronal oblique plane) and at 90 s (axial plane) following intravenous gadolinium. Mean contrast-to-noise ratio was higher on the first than the second acquisition (p < 0.001) and higher on the second acquisition than the third (p < 0.005). Tumour conspicuity was greatest and arterial anatomy was best demonstrated on the first acquisition and the portal venous anatomy on the second. Small tumours were isointense by the third acquisition. Maximal intensity projections were helpful. The MR findings correctly predicted the surgical findings in 11 of 13 cases (85 %) and the clinical course in the other 22 patients. The DCEMR imaging technique is valuable in the staging of patients with pancreatic cancer. Capillary and portal venous phase images are both required for complete local staging. (orig.)

  15. Evaluation of patellar cartilage surface lesions: comparison of CT arthrography and fat-suppressed FLASH 3D MR imaging

    International Nuclear Information System (INIS)

    Daenen, B.R.; Ferrara, M.A.; Marcelis, S.; Dondelinger, R.F.

    1998-01-01

    The aim of this study was to evaluate the sensitivity and specificity of fat-suppressed fast low-angle shot (FLASH) 3D MR imaging in the detection of patellar cartilage surface lesions in comparison with CT arthrography. Fifty patients, with or without symptoms of chondromalacia, were prospectively examined by CT arthrography and fat-suppressed 3D gradient-echo MR imaging. All MR examinations were evaluated by three observers, two of them reaching a consensus interpretation. The lesions were graded according to their morphology and their extent. The CT arthrography was considered as the reference examination. For both sets of observers, the final diagnosis of chondromalacia was obtained in 92.5 %. The specificity was 60 % on a patient-by-patient basis. Fissures were missed in 83 and 60 %, respectively, but were isolated findings only in 2.5 % of the cases. Considering ulcers involving more than 50 % of the cartilage thickness, 65 and 88 %, respectively, were recognized. Fat-suppressed FLASH 3D is an adequate pulse sequence for the detection of patellar cartilage ulcers. It can be applied on a routine clinical basis, but it does not show as many fissures as CT arthrography and is less precise for grading of lesions. (orig.)

  16. Evaluation of patellar cartilage surface lesions: comparison of CT arthrography and fat-suppressed FLASH 3D MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Daenen, B.R.; Ferrara, M.A.; Marcelis, S.; Dondelinger, R.F. [Department of Medical Imaging, University Hospital Sart-Tilman, Liege (Belgium)

    1998-07-01

    The aim of this study was to evaluate the sensitivity and specificity of fat-suppressed fast low-angle shot (FLASH) 3D MR imaging in the detection of patellar cartilage surface lesions in comparison with CT arthrography. Fifty patients, with or without symptoms of chondromalacia, were prospectively examined by CT arthrography and fat-suppressed 3D gradient-echo MR imaging. All MR examinations were evaluated by three observers, two of them reaching a consensus interpretation. The lesions were graded according to their morphology and their extent. The CT arthrography was considered as the reference examination. For both sets of observers, the final diagnosis of chondromalacia was obtained in 92.5 %. The specificity was 60 % on a patient-by-patient basis. Fissures were missed in 83 and 60 %, respectively, but were isolated findings only in 2.5 % of the cases. Considering ulcers involving more than 50 % of the cartilage thickness, 65 and 88 %, respectively, were recognized. Fat-suppressed FLASH 3D is an adequate pulse sequence for the detection of patellar cartilage ulcers. It can be applied on a routine clinical basis, but it does not show as many fissures as CT arthrography and is less precise for grading of lesions. (orig.) With 4 figs., 3 tabs., 21 refs.

  17. Diffusion-weighted MR and apparent diffusion coefficient in the evaluation of severe brain injury

    International Nuclear Information System (INIS)

    Nakahara, M.; Ericson, K.; Bellander, B.M.

    2001-01-01

    Purpose: To study apparent diffusion coefficient (ADC) maps in severely brain-injured patients. Material and Methods: Four deeply comatose patients with severe brain injury were investigated with single-shot, diffusion-weighted, spin-echo echo planar imaging. The tetrahedral diffusion gradient configuration and four iterations of a set of b-values (one time of 0 mm2/s, and four times of 1000 mm2/s) were used to create isotropic ADC maps with high signal-to-noise ratio. ADC values of gray and white matter were compared among patients and 4 reference subjects. Results: one patient was diagnosed as clinically brain dead after the MR examination. The patient's ADC values of gray and white matter were significantly lower than those of 3 other brain-injured patients. In addition the ADC value of white matter was significantly lower than that of gray matter. Conclusion: The patient with fatal outcome shortly after MR examination differed significantly from other patients with severe brain injury but non-fatal outcome, with regard to ADC values in gray and white matter. This might indicate a prognostic value of ADC maps in the evaluation of traumatic brain injury

  18. A study on corrosive behavior of spring steel by shot-peening process

    International Nuclear Information System (INIS)

    An, Jae Pil; Park, Keyung Dong

    2004-01-01

    In this study, the influence of shot peening on the corrosion was investigated on spring steel immersed in 3.5% NaCl. The immersion test was performed on the two kinds of specimens. Corrosion potential, polarization curve, residual stress and etc. were investigated from experimental results. From test results, the effect of shot peening on the corrosion was evaluated. In case of corrosion potential, shot peened specimen shows more activated negative direction as compared with parent metal. Surface of specimen, which is treated with the shot peened, is placed as more activated state against inner base metal. It can cause the anti-corrosion effect on the base metal

  19. 77 FR 36272 - SunShot Prize: America's Most Affordable Rooftop

    Science.gov (United States)

    2012-06-18

    ...The Department of Energy (DOE) announces in this notice the release of the SunShot Prize: America's Most Affordable Rooftop Solar for public comment. Interested persons are encouraged to learn about the SunShot Prize: America's Most Affordable Rooftop rules at eere.energy.gov/solar/sunshot/prize.html.

  20. The Numerical FEM Model of the Kinematics of the Vibratory Shot Peening Process

    Directory of Open Access Journals (Sweden)

    Stanisław Bławucki

    2017-12-01

    Full Text Available The paper presents the results of numerical calculations, with the finite element method in the ABAQUS program environment, of the vibratory shot peening process with loose peening elements. The behaviour of shot peening elements was analysed in the kinematic aspect. The impact of the initial deployment of vibratory shot peening elements on their behaviour during processing was investigated, including the displacement, velocity, acceleration and the number of collisions. The way of determining the effectiveness of the processing with the vibratory shot peening was illustrated.

  1. MR-based source localization for MR-guided HDR brachytherapy

    Science.gov (United States)

    Beld, E.; Moerland, M. A.; Zijlstra, F.; Viergever, M. A.; Lagendijk, J. J. W.; Seevinck, P. R.

    2018-04-01

    For the purpose of MR-guided high-dose-rate (HDR) brachytherapy, a method for real-time localization of an HDR brachytherapy source was developed, which requires high spatial and temporal resolutions. MR-based localization of an HDR source serves two main aims. First, it enables real-time treatment verification by determination of the HDR source positions during treatment. Second, when using a dummy source, MR-based source localization provides an automatic detection of the source dwell positions after catheter insertion, allowing elimination of the catheter reconstruction procedure. Localization of the HDR source was conducted by simulation of the MR artifacts, followed by a phase correlation localization algorithm applied to the MR images and the simulated images, to determine the position of the HDR source in the MR images. To increase the temporal resolution of the MR acquisition, the spatial resolution was decreased, and a subpixel localization operation was introduced. Furthermore, parallel imaging (sensitivity encoding) was applied to further decrease the MR scan time. The localization method was validated by a comparison with CT, and the accuracy and precision were investigated. The results demonstrated that the described method could be used to determine the HDR source position with a high accuracy (0.4–0.6 mm) and a high precision (⩽0.1 mm), at high temporal resolutions (0.15–1.2 s per slice). This would enable real-time treatment verification as well as an automatic detection of the source dwell positions.

  2. Radiologically contaminated lead shot reuse at the Idaho National Engineering Laboratory (INEL)

    International Nuclear Information System (INIS)

    Heileson, W.M.; Grant, R.P.

    1995-01-01

    This project involved the utilization of radioactively contaminated lead shot located at the Radioactive Waste Management Complex (RWMC) for radiation shielding on a radioactive liquid process tank located at Argonne National Laboratory-West (ANL-W). The use of previously contaminated shot precludes the radioactive contamination of clean shot. With limited treatment and disposal options for contaminated lead shot, the reuse of lead for shielding is significant due to the inherent characteristic of becoming a mixed waste when radiologically contaminated. The INEL conducted a lead cleanup campaign in 1990. This was designed to ensure control of potential Resource Conservation and Recovery Act (RCRA) regulated waste. Contaminated lead from throughout the INEL, was containerized per the lead Waste Acceptance Criteria at the generator sites. Limited areas at the INEL are designated for mixed waste storage. As a result, some of the lead was stored at the RWMC in the air support weather shield (ASWS). This lead was contaminated with small amounts of fission product contamination. The lead was in the form of shot, brick, sheet, casks, and other various sized pieces. In 1993, ANL-W identified a need for lead shot to be used as shielding in a radioactive liquid waste storage and processing tank at the Fuel Cycle Facility (FCF). The contaminated lead used on this project had been in storage as mixed waste at the RWMC. This paper will focus on the processes and problems encountered to utilize the contaminated lead shot

  3. Generation of structural MR images from amyloid PET: Application to MR-less quantification.

    Science.gov (United States)

    Choi, Hongyoon; Lee, Dong Soo

    2017-12-07

    Structural magnetic resonance (MR) images concomitantly acquired with PET images can provide crucial anatomical information for precise quantitative analysis. However, in the clinical setting, not all the subjects have corresponding MR. Here, we developed a model to generate structural MR images from amyloid PET using deep generative networks. We applied our model to quantification of cortical amyloid load without structural MR. Methods: We used florbetapir PET and structural MR data of Alzheimer's Disease Neuroimaging Initiative database. The generative network was trained to generate realistic structural MR images from florbetapir PET images. After the training, the model was applied to the quantification of cortical amyloid load. PET images were spatially normalized to the template space using the generated MR and then standardized uptake value ratio (SUVR) of the target regions was measured by predefined regions-of-interests. A real MR-based quantification was used as the gold standard to measure the accuracy of our approach. Other MR-less methods, a normal PET template-based, multi-atlas PET template-based and PET segmentation-based normalization/quantification methods, were also tested. We compared performance of quantification methods using generated MR with that of MR-based and MR-less quantification methods. Results: Generated MR images from florbetapir PET showed visually similar signal patterns to the real MR. The structural similarity index between real and generated MR was 0.91 ± 0.04. Mean absolute error of SUVR of cortical composite regions estimated by the generated MR-based method was 0.04±0.03, which was significantly smaller than other MR-less methods (0.29±0.12 for the normal PET-template, 0.12±0.07 for multiatlas PET-template and 0.08±0.06 for PET segmentation-based methods). Bland-Altman plots revealed that the generated MR-based SUVR quantification was the closest to the SUVR values estimated by the real MR-based method. Conclusion

  4. Robust shot-noise measurement for continuous-variable quantum key distribution

    Science.gov (United States)

    Kunz-Jacques, Sébastien; Jouguet, Paul

    2015-02-01

    We study a practical method to measure the shot noise in real time in continuous-variable quantum key distribution systems. The amount of secret key that can be extracted from the raw statistics depends strongly on this quantity since it affects in particular the computation of the excess noise (i.e., noise in excess of the shot noise) added by an eavesdropper on the quantum channel. Some powerful quantum hacking attacks relying on faking the estimated value of the shot noise to hide an intercept and resend strategy were proposed. Here, we provide experimental evidence that our method can defeat the saturation attack and the wavelength attack.

  5. Consensus for the management of IPMN

    International Nuclear Information System (INIS)

    Tanaka, Masao

    2012-01-01

    International Consensus Guidelines for management of intraductal papillary mucious neoplasms (IPMIN) and mucious cystic neoplasms (MCN) of the pancreas defined their difference in 2006 Sendai Conference, and this paper describes about their still remaining problem in the consensus by referring related literatures. The author explains the macroscopic classification of IPMIN in types of brunch duct (BD), main duct (MD) and their mixture. Guidelines are obscure concerning which of the histology or preoperative imaging is appropriate for diagnosis of the mixed type and the author considers that the latter imaging is better as the method used has influence on indication of surgery thereafter. MD-IPMIN is easily diagnosed differentially from chronic pantreatitis, but differential diagnosis of BD-IPMIN and other cystic lesion is rather complex, particularly, for MCN tending to malignancy and macrocystic serous CN (SCN). For this, analysis of the intraductal mucious liquid obtained by endoscopic ultrasonography-fine needle aspiration biopsy (EUS-FNA) is useful but its safety to see the grade of malignancy for extending the indication leading to resection is not established. Diagnosis of the malignancy of BD-IPMIN can be done best based on the presence of mural nodules, and other markers are of low reliability. In fact, cysts with >3 cm, when resected, are found mostly (80%) benign, indicating the necessity of a more reliable sign and of detailed classification of sub-tissue type. The purpose of progress observation involves diagnoses of changing to malignancy, of concurrent cancer and of recurrence of resected lesion, and an author's case report of this is given with MR cholangiopancreatography (MRCP), CT and MRI images. Observatory approach, interval and period of the disease progression are yet unestablished. (T.T.)

  6. The use of magnetic resonance tomography in gastrointestinal diagnostics

    International Nuclear Information System (INIS)

    Geitung, Jonn Terje

    2000-01-01

    Background: Magnetic resonance imaging (MRI) is a promising method for examination of the gastrointestinal tract. In this article we present the present status and potential of MRI. Material and method: The review is based on personal experience and selected published, international papers. Results: Magnetic resonance cholangio-pancreatography (MRCP) and MRI of the liver are well documented examinations which are widely performed. These examinations partly replace existing modalities such as CT and ERCP and represent additional possibilities for examining this anatomic area. MRI is not as yet accepted as the standard examination of the pancreas, but it is regarded as comparable to CT. The adrenals may be examined even more accurately with MRI than with CT. MRI examinations of the oesophagus and gastric ventricle seem promising, but it should be said that they are in an early and not well document phase. MRI of the small and large bowels is not common. With the exception of preoperative staging of rectal cancers, it is still experimental. MR angiography, functional MRI studies and perfusion studies are not yet common in abdominal diseases. We may, however, believe that they will become important diagnostic tools. Interpretation: MRI is rapidly increasing its share of gastrointestinal imaging examinations. This is mainly due to the increased speed of newer machines. The diagnostic quality has improved and will improve more. It is thus likely that MRI will, in a large amount of abdominal imaging, replace CT and to some extent other diagnostic modalities. It is, however, not possible to replace CT for emergencies and we will probably look forward to more and better imaging with more diagnostic modalities in the future

  7. Finite element modelling of coverage effects during shot peening of IN718

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, Marc; Hoffmeister, Juergen [Inst. fuer Werkstoffkunde I, Karlsruhe Inst. of Tech. (Germany); Schulze, Volker [Inst. fur Produktionstechnik, Karlsruhe Inst. of Tech. (Germany)

    2010-08-15

    Current 3D shot peening simulation models proposed in literature do not take into account coverage as a process parameter influencing the residual state after shot peening. In this study a classic approach, using an ordered dimple pattern, and a new approach, using a stochastic dimple pattern were tested to describe the correlation between coverage, the surface topography and the residual stress state. Model verification was conducted based on X-ray and confocal white light microscopy measurements on shot peened test specimens. The test material was age hardened IN718. Simulations showed that the dimple pattern and the impact order of the shots can have a strong influence on the calculated macroscopic residual stress state. The stochastic approach enabled a realistic prediction of the surface topography and the residual stress state for arbitrary values of coverage while the classic approach strongly underestimated the number of shot impacts needed to achieve a certain value of coverage. (orig.)

  8. Design and Implementation of Video Shot Detection on Field Programmable Gate Arrays

    Directory of Open Access Journals (Sweden)

    Jharna Majumdar

    2012-09-01

    Full Text Available Video has become an interactive medium of communication in everyday life. The sheer volume of video makes it extremely difficult to browse through and find the required data. Hence extraction of key frames from the video which represents the abstract of the entire video becomes necessary. The aim of the video shot detection is to find the position of the shot boundaries, so that key frames can be selected from each shot for subsequent processing such as video summarization, indexing etc. For most of the surveillance applications like video summery, face recognition etc., the hardware (real time implementation of these algorithms becomes necessary. Here in this paper we present the architecture for simultaneous accessing of consecutive frames, which are then used for the implementation of various Video Shot Detection algorithms. We also present the real time implementation of three video shot detection algorithms using the above mentioned architecture on FPGA (Field Programmable Gate Arrays.

  9. Beauty and science in a shot

    Science.gov (United States)

    Ciceri, Piera

    2017-04-01

    Taking pictures has become a daily action for young. Photography is an essential component of many areas of science, has played a crucial role in the study of anatomy, botany, archeology, ... Still today it is a "scientific tool" in the school textbooks: pictures describe, make reality larger or smaller, faster or slower, show evidence and experimental results. But a photograph has the ability to move, engage and inspire viewers. That means that a photograph can build an emotional bridge between science and people. People and students can get closer to science through beautiful, evocative and expressive shot. In this project students are involved in taking pictures with a scientific and aesthetic content looking around, setting an experiment, watching nature, playing with light, point of wiew, colors and perspective. They have to write a short text and a title that explains the scientific content, why and how they have taken the picture. Both description and title should let increase curiosity, could looks fun or stress artistic aspects. Student show their shots in an official public event in Milan managed by a committee of science and photograph experts and in a local event to parents and local community. "Shots of science" is a project promoted by the italian national association "Scienza under 18", the Physic Department of "Università degli Studi di Milano" and the "Museo di fotografia contemporanea" of Cinisello Balsamo (MI) that help students in discussing about scientific and artistic aspects of their shots. This project contributes to develop digital skills (such as to manage digital images, to share documents, to learn about copyright and creative commons license), communication skills (such as to write a caption, public speaking, to use a picture to communicate), collaboration skills (such as to work with pairs, to respect scheduled times, to be positive in giving and taking into account suggestions) and artistic skills (to learn how to compose a good

  10. Finding the gap: An empirical study of the most effective shots in elite goalball.

    Directory of Open Access Journals (Sweden)

    Daniel Link

    Full Text Available This research identifies which shots types in goalball are most likely to lead to a goal and herby provides background information for improving training and competition. Therefore, we observed 117 elite level matches including 20,541 shots played in the regular situation (3 vs. 3 using notational analysis. We characterized the shots by using their target sector (A-E, technique (traditional, rotation, trajectory (flat, bounce, angle (straight, diagonal and outcome (goal, violation, out, blocked. In our data, a χ2-test showed a significantly higher goal rate for men (3.9% compared to women (3.0%. For men, we found a significantly higher goal rate in the intersection sectors between players C (5.6%, D (4.9%, and in the outer sector A. In sector A, goal rate was higher only for straight shots (6.6%. Technique and trajectory did not affect goal rate for men, but flat shots showed a higher violation rate (3.2% compared to bounce shouts (2.0%. In women's goalball, goal rate was higher only on sector D (4.4%. Bounce-rotation shots were the most successful (5.5%. We conclude that men should focus on shots to sectors C and D (called pocket and straight shots to sector A, as long as there are no other tactical considerations. Women should shoot primarily towards the pocket. It might also be worth playing more bounce-rotation shots and practicing them in training.

  11. Finding the gap: An empirical study of the most effective shots in elite goalball.

    Science.gov (United States)

    Link, Daniel; Weber, Christoph

    2018-01-01

    This research identifies which shots types in goalball are most likely to lead to a goal and herby provides background information for improving training and competition. Therefore, we observed 117 elite level matches including 20,541 shots played in the regular situation (3 vs. 3) using notational analysis. We characterized the shots by using their target sector (A-E), technique (traditional, rotation), trajectory (flat, bounce), angle (straight, diagonal and outcome (goal, violation, out, blocked). In our data, a χ2-test showed a significantly higher goal rate for men (3.9%) compared to women (3.0%). For men, we found a significantly higher goal rate in the intersection sectors between players C (5.6%), D (4.9%), and in the outer sector A. In sector A, goal rate was higher only for straight shots (6.6%). Technique and trajectory did not affect goal rate for men, but flat shots showed a higher violation rate (3.2%) compared to bounce shouts (2.0%). In women's goalball, goal rate was higher only on sector D (4.4%). Bounce-rotation shots were the most successful (5.5%). We conclude that men should focus on shots to sectors C and D (called pocket) and straight shots to sector A, as long as there are no other tactical considerations. Women should shoot primarily towards the pocket. It might also be worth playing more bounce-rotation shots and practicing them in training.

  12. Numerical simulation of the shot peening process under previous loading conditions

    International Nuclear Information System (INIS)

    Romero-Ángeles, B; Urriolagoitia-Sosa, G; Torres-San Miguel, C R; Molina-Ballinas, A; Benítez-García, H A; Vargas-Bustos, J A; Urriolagoitia-Calderón, G

    2015-01-01

    This research presents a numerical simulation of the shot peening process and determines the residual stress field induced into a component with a previous loading history. The importance of this analysis is based on the fact that mechanical elements under shot peening are also subjected to manufacturing processes, which convert raw material into finished product. However, material is not provided in a virgin state, it has a previous loading history caused by the manner it is fabricated. This condition could alter some beneficial aspects of the residual stress induced by shot peening and could accelerate the crack nucleation and propagation progression. Studies were performed in beams subjected to strain hardening in tension (5ε y ) before shot peening was applied. Latter results were then compared in a numerical assessment of an induced residual stress field by shot peening carried out in a component (beam) without any previous loading history. In this paper, it is clearly shown the detrimental or beneficial effect that previous loading history can bring to the mechanical component and how it can be controlled to improve the mechanical behavior of the material

  13. Effects of Rayleigh damping, friction and rate-dependency on 3D residual stress simulation of angled shot peening

    International Nuclear Information System (INIS)

    Kim, Taehyung; Lee, Hyungyil; Hyun, Hong Chul; Jung, Sunghwan

    2013-01-01

    Highlights: ► We propose a 3D FE model to study peening residual stress involving angled shots. ► The FE model set with plastic shot are found to best match the X-ray diffraction data. ► The model provides 3D multi-shot impact FE solution with various incidence angles. - Abstract: In this study, we propose a 3D finite element (FE) model to study shot peening involving angled shots. Using the FE model for angled shot peening, we examine relationships with the residual stress introduced by shot peening of the factors such as the Rayleigh damping in the material, dynamic friction, and the rate dependency of the material and systematically integrate them with the FE model. The FE model is set with rigid shot, elastic shot, and plastic shot respectively. Plastic deformation of the shot is also explored with the FE model. The FE model is applied to study angled multi-shots. The FE results are verified with experimental data using X-ray diffraction (XRD). The FE model set with plastic shot are found to best match the XRD results validating accuracy of the 3D FE model properly integrated with the factors and plastically deformable shot ball. The proposed model will serve to simulate actual shot peening cases, which generally involve multi-shots with various incidence angles

  14. SnapShot: The Bacterial Cytoskeleton.

    Science.gov (United States)

    Fink, Gero; Szewczak-Harris, Andrzej; Löwe, Jan

    2016-07-14

    Most bacteria and archaea contain filamentous proteins and filament systems that are collectively known as the bacterial cytoskeleton, though not all of them are cytoskeletal, affect cell shape, or maintain intracellular organization. To view this SnapShot, open or download the PDF. Copyright © 2016. Published by Elsevier Inc.

  15. Use and Perceptions of Caffeinated Energy Drinks and Energy Shots in Canada.

    Science.gov (United States)

    Wiggers, Danielle; Reid, Jessica L; White, Christine M; Hammond, David

    2017-12-01

    In Canada, energy drinks and energy shots are currently classified and regulated differently (food and drugs versus natural health products, respectively), on the assumption that they are used and perceived differently. The current study examined potential differences in use and perceptions of energy drinks and shots. An online survey was conducted in 2015 using a national commercial online panel of youth and young adults aged 12-24 years (n=2,040 retained for analysis in 2016). Participants were randomized to view an image of an energy shot or drink, and were asked about 14 potential reasons for using the product. Past consumption of each product was also assessed. Chi-square and t-tests were conducted to examine differences in use and perceptions between products. Overall, 15.6% of respondents reported using both energy shots and drinks. Of all respondents, ordering of the reasons for use of each product was comparable. Despite differences in prevalence of ever-use of energy shots and drinks, consumption patterns and perceived reasons for using the products are similar. The findings provide little support for regulating energy shots differently than energy drinks. Copyright © 2017 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  16. MR tractography

    International Nuclear Information System (INIS)

    Kinosada, Yasutomi; Okuda, Yasuyuki; Ono, Mototsugu

    1993-01-01

    We developed a new noninvasive technique to visualize the anatomical structure of the nerve fiber system in vivo, and named this technique magnetic resonance (MR) tractography and the acquired image an MR tractogram. MR tractography has two steps. One is to obtain diffusion-weighted images sensitized along axes appropriate for depicting the intended nerve fibers with anisotropic water diffusion MR imaging. The other is to extract the anatomical structure of the nerve fiber system from a series of diffusion-weighted images by the maximum intensity projection method. To examine the clinical usefulness of the proposed technique, many contiguous, thin (3 mm) coronal two-dimensional sections of the brain were acquired sequentially in normal volunteers and selected patients with paralyses, on a 1.5 Tesla MR system (Signa, GE) with an ECG-gated Stejskal-Tanner pulse sequence. The structure of the nerve fiber system of normal volunteers was almost the same as the anatomy. The tractograms of patients with paralyses clearly showed the degeneration of nerve fibers and were correlated with clinical symptoms. MR tractography showed great promise for the study of neuroanatomy and neuroradiology. (author)

  17. A focal-spot diagnostic for on-shot characterization of high-energy petawatt lasers.

    Science.gov (United States)

    Bromage, J; Bahk, S-W; Irwin, D; Kwiatkowski, J; Pruyne, A; Millecchia, M; Moore, M; Zuegel, J D

    2008-10-13

    An on-shot focal-spot diagnostic for characterizing high-energy, petawatt-class laser systems is presented. Accurate measurements at full energy are demonstrated using high-resolution wavefront sensing in combination with techniques to calibrate on-shot measurements with low-power sample beams. Results are shown for full-energy activation shots of the OMEGA EP Laser System.

  18. Neural computations mediating one-shot learning in the human brain.

    Directory of Open Access Journals (Sweden)

    Sang Wan Lee

    2015-04-01

    Full Text Available Incremental learning, in which new knowledge is acquired gradually through trial and error, can be distinguished from one-shot learning, in which the brain learns rapidly from only a single pairing of a stimulus and a consequence. Very little is known about how the brain transitions between these two fundamentally different forms of learning. Here we test a computational hypothesis that uncertainty about the causal relationship between a stimulus and an outcome induces rapid changes in the rate of learning, which in turn mediates the transition between incremental and one-shot learning. By using a novel behavioral task in combination with functional magnetic resonance imaging (fMRI data from human volunteers, we found evidence implicating the ventrolateral prefrontal cortex and hippocampus in this process. The hippocampus was selectively "switched" on when one-shot learning was predicted to occur, while the ventrolateral prefrontal cortex was found to encode uncertainty about the causal association, exhibiting increased coupling with the hippocampus for high-learning rates, suggesting this region may act as a "switch," turning on and off one-shot learning as required.

  19. The effect of court location and available time on the tactical shot selection of elite squash players.

    Science.gov (United States)

    Vučković, Goran; James, Nic; Hughes, Mike; Murray, Stafford; Sporiš, Goran; Perš, Janez

    2013-01-01

    No previous research in squash has considered the time between shots or the proximity of the ball to a wall, which are two important variables that influence shot outcomes. The aim of this paper was to analyse shot types to determine the extent to which they are played in different court areas and a more detailed analysis to determine whether the time available had an influence on the shot selected. Ten elite matches, contested by fifteen of the world's top right handed squash players (age 27 ± 3.2, height 1.81 ± 0.06 m, weight 76.3 ± 3.7 kg), at the men's World Team Championships were processed using the SAGIT/Squash tracking system with shot information manually added to the system. Results suggested that shot responses were dependent upon court location and the time between shots. When these factors were considered repeatable performance existed to the extent that one of two shots was typically played when there was limited time to play the shot (tactics affect shot selections. Key pointsPrevious research has suggested that a playing strategy, elements decided in advance of the match, may be evident for elite players by examining court location and preceding shot type, however these parameters alone are unlikely to be sufficient predictors.At present there is no known analysis in squash, or indeed in any of the racket sports, that has quantified the time available to respond to different shot types. An understanding of the time interval between shots and the movement characteristics of the player responding to different shots according to the court positions might facilitate a better understanding of the dynamics that determine shot selection.Some elements of a general playing strategy were evident e.g. predominately hitting to the back left of the court, but tactical differences in shot selection were also evident on the basis of court location and time available to play a shot.

  20. Study on the use of types of shots in Valencian Handball on professional players

    Directory of Open Access Journals (Sweden)

    José Antonio Martínez Carbonell

    2013-01-01

    Full Text Available Due to the shortage of studies of analysis in Valencian ball, we have centred this study on this sport. The aim of study has been to analyze and to quantify the types of shots , and to compare the same ones between the positions of game of 1st game line (resto and 2nd game line (medio. Analysis of 6 games of the 19th Professional League of Stand and rope 2009-2010 was carried out so i, and specifically of 12 players, using Sports Code analysis software. The results indicate significant differences (p<0.05 between the shots carried out by first game line player and second game line in the rebound and rebound-shot all of them of right and left hand,and stand shot right hand; being almost realitzados only by players from the first game line position. At the same time we find data which demonstrate us by another band used mainly by second game line players beatings, these have been volley shot, volley shot after bounce, volley shot under the line of the shoulders, palm shot and horizontal shot all of them of right hand. As conclusion of the study, we have obtained that depending on the position of game the players use a few types of I throb or others. Therefore, we affirm, that the analysis of the high performance in stand and rope from the advances of the technologies, a valuable information contributes us to establish specific bosses of training.

  1. The importance of reliability to the SunShot Initiative (Presentation Recording)

    Science.gov (United States)

    Jones-Albertus, Rebecca

    2015-09-01

    The U.S. Department of Energy's SunShot Initiative was launched in 2011 to make subsidy-free solar electricity cost competitive with conventional energy sources by the end of the decade. Research in reliability can play a major role in realizing the SunShot goal of 0.06/kWh. By improving photovoltaic module lifetime and reducing degradation rates, a system's lifetime energy output is increased. Increasing confidence in photovoltaic performance prediction can lower perceived investment risk and thus the cost of capital. Accordingly, in 2015, SunShot expects to award more than $40 million through its SunShot National Laboratory Multiyear Partnership (SuNLaMP) and Physics of Reliability: Evaluating Design Insights for Component Technologies in Solar (PREDICTS) 2 funding programs, for research into reliability topics such as determining acceleration factors, modeling degradation rates and failure mechanisms, improving predictive performance models, and developing new test methods and instrumentation.

  2. MR-guided biopsies

    International Nuclear Information System (INIS)

    Gehl, H.B.; Frahm, C.

    1998-01-01

    Biopsies were the first 'intervention' under MR guidance. After initial difficulties concerning ferromagnetic biopsy instruments and the design of MR scanners, the latest technological improvements rendered MR guidance for biopsies more feasible. In this article we illustrate present-day clinical experience in the field of abdominal, breast and bone biopsy. Important aspects regarding the different designs of 'interventional' MR scanners and the visualization of instruments for biopsy are discussed. (orig.) [de

  3. Advances in endoscopic retrograde cholangiopancreatography for the treatment of cholangiocarcinoma.

    Science.gov (United States)

    Uppal, Dushant S; Wang, Andrew Y

    2015-06-25

    Cholangiocarcinoma (CCA) is a malignancy of the bile ducts that carries high morbidity and mortality. Patients with CCA typically present with obstructive jaundice, and associated complications of CCA include cholangitis and biliary sepsis. Endoscopic retrograde cholangiopancreatography (ERCP) is a valuable treatment modality for patients with CCA, as it enables internal drainage of blocked bile ducts and hepatic segments by using plastic or metal stents. While there remains debate as to if bilateral (or multi-segmental) hepatic drainage is required and/or superior to unilateral drainage, the underlying tenant of draining any persistently opacified bile ducts is paramount to good ERCP practice and good clinical outcomes. Endoscopic therapy for malignant biliary strictures from CCA has advanced to include ablative therapies via ERCP-directed photodynamic therapy (PDT) or radiofrequency ablation (RFA). While ERCP techniques cannot cure CCA, advancements in the field of ERCP have enabled us to improve upon the quality of life of patients with inoperable and incurable disease. ERCP-directed PDT has been used in lieu of brachytherapy to provide neoadjuvant local tumor control in patients with CCA who are awaiting liver transplantation. Lastly, mounting evidence suggests that palliative ERCP-directed PDT, and probably ERCP-directed RFA as well, offer a survival advantage to patients with this difficult-to-treat malignancy.

  4. Kinematic and kinetic analysis of overhand, sidearm and underhand lacrosse shot techniques.

    Science.gov (United States)

    Macaulay, Charles A J; Katz, Larry; Stergiou, Pro; Stefanyshyn, Darren; Tomaghelli, Luciano

    2017-12-01

    Lacrosse requires the coordinated performance of many complex skills. One of these skills is shooting on the opponents' net using one of three techniques: overhand, sidearm or underhand. The purpose of this study was to (i) determine which technique generated the highest ball velocity and greatest shot accuracy and (ii) identify kinematic and kinetic variables that contribute to a high velocity and high accuracy shot. Twelve elite male lacrosse players participated in this study. Kinematic data were sampled at 250 Hz, while two-dimensional force plates collected ground reaction force data (1000 Hz). Statistical analysis showed significantly greater ball velocity for the sidearm technique than overhand (P  0.05). Kinematic and kinetic variables were not significantly correlated to shot accuracy or velocity across all shot types; however, when analysed independently, the lead foot horizontal impulse showed a negative correlation with underhand ball velocity (P = 0.042). This study identifies the technique with the highest ball velocity, defines kinematic and kinetic predictors related to ball velocity and provides information to coaches and athletes concerned with improving lacrosse shot performance.

  5. Shot peening speed measurements using lidar technology

    DEFF Research Database (Denmark)

    Angelou, Nikolas; Zhang, Xiaodan; Sjöholm, Mikael

    The shot peening technique is used for the surface modification of metallic components that are part of wind turbines, such as gears, bolts and blade coatings to prevent erosion. An important parameter of this technique is the dynamic energy of emitted shots. In this context the objective......, the risk of damaging the peening machine by installing an instrument inside the chamber during operation is eliminated by this approach. Laser anemometers are being researched and developed in the department of Wind Energy, mainly in the framework of the WindScanner.dk infrastructure project [1], but also...... validated and used in monitoring the wind conditions around wind turbines (wake and inflow), over complex terrain as well as offshore....

  6. Correction of distortion of MR pictures for MR-guided robotic sterotactic procedures

    International Nuclear Information System (INIS)

    Jonckheere, E.A.; Kwoh, Y.S.

    1988-01-01

    Ever since magnetic resonance (MR) invaded the medical imaging field, it has played an increasingly important role and is even currently being considered for stereotactic guidance of probes in the brain. While MR pictures indeed convey more clinical information than CT, the geometry of MR pictures is, unfortunately, not as accurate as the geometry of CT pictures. In other words, if a square grid phantom is scanned, then the CT picture will show a square grid, while the MR picture will rather reveal a distorted grid. This distortion is primarily due to small variations in the static magnetic field. This small distortion does not impede radiological diagnosis; however, it is a source of concern if one contemplates utilizing the MR pictures for accurate stereotactic positioning of a probe at a very precise point in the brain. Another area of application where the distortion of the MR picture should be compensated for is the superposition of CT and MR pictures so that both informations could be used for diagnosis or stereotactic purposes. This paper essentially addresses the nonlinear distortion of MR pictures and how it could be compensated for through software manipulation of the MR picture

  7. RF Shot Noise Measurements in Au Atomic-scale Junctions

    Science.gov (United States)

    Chen, Ruoyu

    Conduction electrons are responsible for many physical or chemical phenomena in condensed matter systems, and their behavior can be directly studied by electronic transport measurements. In conventional transport measurements, conductance or resistance is usually the focus. Such a measurement can be as simple as a quick two terminal DC check by a multi-meter, or a more sophisticated lock-in measurement of multiple higher harmonic signals synchronized to different frequencies. Conductance carries direct information about the quasi-particle density of states and the local electronic distributions, which are usually Fermi-Dirac distribution. Conductance is modified or dominated by scattering from defacts or interfaces, and could also reflect the spin-spin exchange interactions or inelastic couplings with phonons and photons. Naturally one can ask the question: is there anything else we can measure electronically, which carries extra information that a conductance measurement does not provide? One answer to this question is the electronic noise. While the conductance reflects the average charge conduction ability of a system, noise describes how the physical quantities fluctuate around their average values. Some of the fluctuations carry information about their physical origins. This thesis will focus on one particular type of the electronic noise shot noise, but other types of noise will also be introduced and discussed. We choose to measure the radio frequency component of shot noise, combining with a modulated lock-in detection technique, which provides a method to largely get rid of other unwanted low-frequency noise signals. Au atomic-scale junctions are the systems we studied here. Au is relatively well understood and will not generate too many complications, so it's ideal as the first platform for us to understand both shot noise itself and our RF technique. On the other hand, the atomic scale raises fundamental questions about electronic transport and local

  8. The Distribution of the Interval between Events of a Cox Process with Shot Noise Intensity

    Directory of Open Access Journals (Sweden)

    Angelos Dassios

    2008-01-01

    Full Text Available Applying piecewise deterministic Markov processes theory, the probability generating function of a Cox process, incorporating with shot noise process as the claim intensity, is obtained. We also derive the Laplace transform of the distribution of the shot noise process at claim jump times, using stationary assumption of the shot noise process at any times. Based on this Laplace transform and from the probability generating function of a Cox process with shot noise intensity, we obtain the distribution of the interval of a Cox process with shot noise intensity for insurance claims and its moments, that is, mean and variance.

  9. Music video shot segmentation using independent component analysis and keyframe extraction based on image complexity

    Science.gov (United States)

    Li, Wei; Chen, Ting; Zhang, Wenjun; Shi, Yunyu; Li, Jun

    2012-04-01

    In recent years, Music video data is increasing at an astonishing speed. Shot segmentation and keyframe extraction constitute a fundamental unit in organizing, indexing, retrieving video content. In this paper a unified framework is proposed to detect the shot boundaries and extract the keyframe of a shot. Music video is first segmented to shots by illumination-invariant chromaticity histogram in independent component (IC) analysis feature space .Then we presents a new metric, image complexity, to extract keyframe in a shot which is computed by ICs. Experimental results show the framework is effective and has a good performance.

  10. Fatal air embolism during endoscopic retrograde cholangiopancreatography (ERCP): An 'impossible' diagnosis for the forensic pathologist.

    Science.gov (United States)

    Marchesi, Matteo; Battistini, Alessio; Pellegrinelli, Moira; Gentile, Guendalina; Zoja, Riccardo

    2016-01-01

    Fatal air embolism related to endoscopic retrograde cholangiopancreatography is a very rare phenomenon. The authors describe the case of a 51-year-old female patient who developed this mortal complication; a computed tomography (CT) examination was performed in articulo mortis by the physicians. Autopsy was unreliable because of bizarre post-mortem changes (reabsorption of intra-cardiac gas vs. conservation of intra-cranial gas) and a lack of strong diagnostic value of histological findings. The right diagnosis was possible thanks only to the CT examination that permitted the assumption of this possible cause of death before the autopsy and to prepare the necessary procedures to recognise and probe air embolism. This case exemplifies how early post-mortem imaging can be crucial to avoid a wrong diagnosis. © The Author(s) 2015.

  11. High human exposure to lead through consumption of birds hunted with lead shot

    International Nuclear Information System (INIS)

    Johansen, P.; Asmund, G.; Riget, F.

    2004-01-01

    Lead shot contaminates the edible parts of birds so that tolerable human lead intake is exceeded. - We assess lead contamination of Greenland seabirds killed with lead shot having studied thick-billed murre and common eider, the two most important species in the diet. The lead concentration is very high in meat of eiders killed with lead shot (mean 6.1 μg/g-wet wt, 95% CL 2.1-12). This level is about 44 times higher than in drowned eiders and eight times higher than in shot murres. Analyzing whole breasts instead of sub-samples reveals about seven times higher lead levels in birds' meat. We conclude that in some cases the lead intake by Greenland bird eaters will largely exceed the FAO/WHO tolerable lead intake guideline and that lead shot is a more important source of lead in the diet than previously estimated

  12. IMPACT OF VIBRATORY AND ROTATIONAL SHOT PEENING ONTO SELECTED PROPERTIES OF TITANIUM ALLOY SURFACE LAYER

    Directory of Open Access Journals (Sweden)

    Kazimierz Zaleski

    2014-06-01

    Full Text Available This study presents the results of tests on impact of vibratory and rotational shot peening of the Ti6A12Mo2Cr titanium alloy onto the processed object surface roughness and surface layer microhardness. The external surfaces of ring-shaped samples were shot peened. The preceding process consisted of turning with a cubic boron nitride blade knife. Steel beads, having a diameter of 6 mm, were used as a processing medium. The variable parameters of shot peening were vibrator amplitude and shot peening time. The range of recommended technological parameters for vibratory and rotational shot peening was determined. As a result of shot peening, the surface roughness could be reduced by approximately 4 times and the surface layer could be hardened to the depth of approximately 0.4 mm.

  13. Pseudotumor of the distal common bile duct at endoscopic retrograde cholangiopancreatography

    Science.gov (United States)

    Tan, Justin H.; Coakley, Fergus V; Wang, Zhen J.; Poder, Liina; Webb, Emily; Yeh, Benjamin M.

    2010-01-01

    Background Prior studies have described a pseudocalculus appearance in the distal common bile duct as a normal variant at cholangiography. The objective of this study is to describe the occurrence of pseudotumor in the distal common bile duct at endoscopic retrograde cholangiopancreatography (ERCP). Methods Nine patients who underwent ERCP between May 2004 and July 2008 were identified as having a transient eccentric mural-based filling defect in the distal common bile duct. A single reader systematically reviewed all studies and recorded the imaging findings. Results The mean diameter of the filling defect was 9 mm (range, 5 to 11). Eight patients had resolution of the filling defect during the same ERCP or on a subsequent ERCP, and in 2 of these patients the inferior border of the filling defect was not well visualized. The other patient underwent surgical resection of a presumed tumor with no evidence of malignancy on surgical pathology. Conclusion An eccentric mural-based filling defect in the distal common bile duct can be artifactual in nature and may reflect transient contraction of the sphincter of Oddi. Recognition of this pseudotumor may help avoid unnecessary surgery. PMID:21724120

  14. Assessment of patient dose and radiogenic risks during endoscopic retrograde cholangiopancreatography

    Energy Technology Data Exchange (ETDEWEB)

    Sulieman, A.; Elzaki, M. [Sudan University of Science and Technology, College of Medical Radiologic Science, P. O. Box 1908, Khartoum 11111 (Sudan); Alkhorayef, M.; Babikir, E. [King Saud University, College of Applied Sciences, Radiological Sciences Department, P. O. Box 10219, Riyadh 11433 (Saudi Arabia); Abuzaid, M. [University of Sharjah, College of Health Sciences, Medical Diagnostic Imaging Department, Sharjah (United Arab Emirates); Dalton, A.; Bradley, D., E-mail: Abdelmoneim_a@yahoo.com [University of Surrey, Centre for Nuclear and Radiation Physics, Department of Physics, GU2-7XH, Guildford, Surrey (United Kingdom)

    2015-10-15

    Endoscopic retrograde cholangiopancreatography (ERCP) is an invasive technique that has been used for over 30 years in the diagnosis and management of pancreaticobiliary disorders. The objectives of this study were to evaluate the patient entrance surface air kerma doses (ESAK) and estimate the organ and effective doses during ERCP in three hospitals in Khartoum. A total of 55 patients were examined in three hospitals in Khartoum state, Sudan. Calibrated thermoluminescence dosimeters (TLD)-Gr-200-A)) were used to measure patients ESAK. The overall mean of ESAK for all ERCP procedures was 42.4 mGy. The mean patient ESAK in Fedail, Soba and Ibn sena centers were 26.7 mGy, 26.0 mGy, 72.4 mGy, respectively. The effective doses in three centers were 1.6, 1.56 and 2.67 mSv in that order and the overall mean effective dose was 2.01 mSv. Patient radiation doses vary widely among the different hospitals. Patient ESAK is low compared to previous studies in the light of the current practice. Patient dose was decreased significantly in the last two decades. (Author)

  15. Assessment of patient dose and radiogenic risks during endoscopic retrograde cholangiopancreatography

    International Nuclear Information System (INIS)

    Sulieman, A.; Elzaki, M.; Alkhorayef, M.; Babikir, E.; Abuzaid, M.; Dalton, A.; Bradley, D.

    2015-10-01

    Endoscopic retrograde cholangiopancreatography (ERCP) is an invasive technique that has been used for over 30 years in the diagnosis and management of pancreaticobiliary disorders. The objectives of this study were to evaluate the patient entrance surface air kerma doses (ESAK) and estimate the organ and effective doses during ERCP in three hospitals in Khartoum. A total of 55 patients were examined in three hospitals in Khartoum state, Sudan. Calibrated thermoluminescence dosimeters (TLD)-Gr-200-A)) were used to measure patients ESAK. The overall mean of ESAK for all ERCP procedures was 42.4 mGy. The mean patient ESAK in Fedail, Soba and Ibn sena centers were 26.7 mGy, 26.0 mGy, 72.4 mGy, respectively. The effective doses in three centers were 1.6, 1.56 and 2.67 mSv in that order and the overall mean effective dose was 2.01 mSv. Patient radiation doses vary widely among the different hospitals. Patient ESAK is low compared to previous studies in the light of the current practice. Patient dose was decreased significantly in the last two decades. (Author)

  16. Usefulness of enteral contrast media in MR evaluation of pelvic mass

    International Nuclear Information System (INIS)

    Kim, Hun; Kim, Jung Sik; Kim, Hong; Shon, Chul Ho; Lee, Hee Jung; Lee, Sung Moon; Woo, Sung Ku; Suh, Soo Jhi

    1999-01-01

    To assess the value of enteral contrast media for the evaluation of pelvic masses by MR imaging. Between April and July 1998, 16 women with pelvic masses were examined by MRI. The origin of the lesion was the ovary in twelve cases, the uterus in three, and the sigmoid in one. Using a 1.5T scanner(Magnetom Vision, Siemens), T1-weighted axial spin echo(SE), T2-weighted turbo spin echo(TSE), two dimensional fast low-angle shot(FLASH 2D), and half-Fourier TSE(HASTE) images were obtained in all patients after the administration of Magnevist Enteral (Shering, Berlin, Germany). In each MR imagine sequence, distinction between the lesion and adjacent bowel (1, not distinguished; 2, partly distinguished; 3, clearly distinguished), artifact (0, absent; 1, mild; 2, severe), image quality (1, poor; 2, fair; 3, good), were compared before and after the use of enteral contrast media. Changes in MRI impression after the use of enteral contrast media were also evaluated. Two radiologists reached a consensus after reviewing the images. Statistical significance was determined by Wilcoxon's signed ranked test. For distinguishing lesions, SE T1WI and FLASH 2D with enteral contrast media were significantly superior to SE T1WI without enteral contrast media (p < 0.05). With regard to image quality, FLASH 2D and HASTE, both with enteral contrast media, were significantly superior to SE T1WI and TSE T2WI, respectively, both without enteral contrast media (p < 0.05). Artefacts were more frequently found after the application of enteral contrast media in conventional sequences but were not present in breathhold sequences. In two patients, MRI impression changed after the application of enteral contrast media. In a limited number of cases, enteral contrast media improved lesion detection, image quality and diagnostic accuracy when breathhold fast MR imaging was applied

  17. Choledocholithiasis: Evolving standards for diagnosis and management

    Institute of Scientific and Technical Information of China (English)

    Marilee L Freitas; Robert L Bell; Andrew J Duffy

    2006-01-01

    Cholelithiasis, one of the most common medical conditions leading to surgical intervention, affects approximately 10 % of the adult population in the United States.Choledocholithiasis develops in about 10%-20% of patients with gallbladder stones and the literature suggests that at least 3%-10% of patients undergoing cholecystectomy will have common bile duct (CBD) stones.CBD stones may be discovered preoperatively, intraoperatively or postoperatively Multiple modalities are available for assessing patients for choledocholithiasis including laboratory tests, ultrasound, computed tomography scans (CT), and magnetic resonance cholangiopancreatography (MRCP). Intraoperative cholangiography during cholecystectomy can be used routinely or selectively to diagnose CBD stones.The most common intervention for CBD stones is ERCP. Other commonly used interventions include intraoperative bile duct exploration, either laparoscopic or open. Percutaneous, transhepatic stone removal other novel techniques of biliary clearance have been devised.The availability of equipment and skilled practitioners who are facile with these techniques varies among institutions. The timing of the intervention is often dictated by the clinical situation.

  18. Primary Follicular Lymphoma of the Common Bile Duct Mimicking Cholangiocarcinoma

    Directory of Open Access Journals (Sweden)

    Khaled Youssef Elbanna

    2014-01-01

    Full Text Available Primary non-Hodgkin′s lymphoma of the common bile duct is extremely rare. We present a case with history of inflammatory bowel disease and clinical manifestations of obstructive jaundice. Abdominal magnetic resonance imaging with magnetic resonance cholangiopancreatography (MRCP was done and demonstrated tight stricture at the middle part of common bile duct, and radiological findings were supportive of extra-hepatic cholangiocarcinoma. Whipple′s procedure was performed and the case was histopathologically proven to be non-Hodgkin′s lymphoma of follicular subtype involving the common bile duct. Lymphoma of the hepatobiliary system is usually present as secondary manifestation of systemic malignant lymphoma. However, primary malignant lymphomas arising from the hepatobiliary tree are extremely rare. The radiological appearance of common bile duct lymphoma is very similar to cholangiocarcinoma, making preoperative diagnosis very difficult, as in our present case. We also compare the imaging findings of our case to those seen in reported cases of follicular lymphoma of the common bile duct.

  19. Single-shot measurement of nonlinear absorption and nonlinear refraction.

    Science.gov (United States)

    Jayabalan, J; Singh, Asha; Oak, Shrikant M

    2006-06-01

    A single-shot method for measurement of nonlinear optical absorption and refraction is described and analyzed. A spatial intensity variation of an elliptical Gaussian beam in conjugation with an array detector is the key element of this method. The advantages of this single-shot technique were demonstrated by measuring the two-photon absorption and free-carrier absorption in GaAs as well as the nonlinear refractive index of CS2 using a modified optical Kerr setup.

  20. Influence of the shot-peening treatment on the CRF gearing behaviour

    International Nuclear Information System (INIS)

    Molinie, D.; Lemaire, E.; Randrianarivo, L.; Dorier, C.

    1998-01-01

    Surface damage are observed in service on CRF case-hardened cases. Such damage is like surface fatigue which appears in the form of frosting and can come to a micro-spalling or even a spalling damage. Survey and studies realised on gears affected by such damage, led EDF and the manufacturer to search for appropriated solutions since 1985 (optimisation of the gear bottom profile, care of the grinding and the thermochemical processing, use of oils with higher viscosity). Simulations on a running wheel device can reproduce the meshing conditions on simplified specimen. The aim is to study the influence of residual stresses following a severe grinding and shot peening treatments. An empiric selection was realised among different shot peening treatments. Endurance tests are realised on case-hardened gears with or without shot-peening treatments. Compared with standard grinded gears, it appears that the shot-peening selected increases up to 40% the gear lifetime till extended spalling. (authors)

  1. Shot H3837: Darht's First Dual-Axis Explosive Experiment

    Science.gov (United States)

    Mendez, Jacob; McNeil, Wendy Vogan; Harsh, James; Hull, Lawrence

    2011-06-01

    Test H3837 was the first explosive shot performed in front of both flash x-ray axes at the Los Alamos Dual Axis Radiographic HydroTest (DARHT) facility. Executed in November 2009, the shot was an explosively-driven metal flyer plate in a series of experiments designed to explore equation-of-state properties of shocked materials. Imaging the initial shock wave traveling through the flyer plate, DARHT Axis II captured the range of motion from the shock front emergence in the flyer to breakout at the free surface; the Axis I pulse provided a perpendicular perspective of the shot at a time coinciding with the third pulse of Axis II. Since the days of the Manhattan Project, penetrating radiography with multiple frames from different viewing angles has remained a high-profile goal at the Laboratory. H3837 is merely the beginning of a bright future for two-axis penetrating radiography.

  2. High-Fidelity Single-Shot Toffoli Gate via Quantum Control.

    Science.gov (United States)

    Zahedinejad, Ehsan; Ghosh, Joydip; Sanders, Barry C

    2015-05-22

    A single-shot Toffoli, or controlled-controlled-not, gate is desirable for classical and quantum information processing. The Toffoli gate alone is universal for reversible computing and, accompanied by the Hadamard gate, forms a universal gate set for quantum computing. The Toffoli gate is also a key ingredient for (nontopological) quantum error correction. Currently Toffoli gates are achieved by decomposing into sequentially implemented single- and two-qubit gates, which require much longer times and yields lower overall fidelities compared to a single-shot implementation. We develop a quantum-control procedure to construct a single-shot Toffoli gate for three nearest-neighbor-coupled superconducting transmon systems such that the fidelity is 99.9% and is as fast as an entangling two-qubit gate under the same realistic conditions. The gate is achieved by a nongreedy quantum control procedure using our enhanced version of the differential evolution algorithm.

  3. Subjective State, Blood Pressure, and Behavioral Control Changes Produced by an "Energy Shot"

    Science.gov (United States)

    Marczinski, Cecile A; Stamates, Amy L; Ossege, Julianne; Maloney, Sarah F; Bardgett, Mark E; Brown, Clifford J

    2014-06-01

    Background: Energy drinks and energy shots are popular consumer beverages that are advertised to increase feelings of alertness. Typically, these products include high levels of caffeine, a mild psychostimulant drug. The scientific evidence demonstrating the specific benefits of energy products to users in terms of subjective state and objective performance is surprisingly lacking. Moreover, there are rising health concerns associated with the use of these products. Therefore, the purpose of this study was to investigate the acute effects of a popular energy shot (5-Hour Energy ® ) on subjective and objective measures that were assessed hourly for 6 hours following consumption. Methods: Participants ( n =14) completed a three-session study where they received the energy shot, a placebo control, and no drink. Following dose administration, participants completed subjective Profile of Mood States ratings hourly for 6 hours. Participants also repeatedly completed a behavioral control task (the cued go/no-go task) and provided blood pressure and pulse rate readings at each hour. Results: Consumption of the energy shot did improve subjective state, as measured by increased ratings of vigor and decreased ratings of fatigue. However, the energy shot did not alter objective performance, which worsened over time. Importantly, the energy shot elevated both systolic and diastolic blood pressure. Conclusions: Consumption of one energy shot may only result in modest benefits to subjective state. Individuals with preexisting hypertension or other medical conditions should be cautious about using these new consumer products.

  4. MR Imaging-Guided Attenuation Correction of PET Data in PET/MR Imaging.

    Science.gov (United States)

    Izquierdo-Garcia, David; Catana, Ciprian

    2016-04-01

    Attenuation correction (AC) is one of the most important challenges in the recently introduced combined PET/magnetic resonance (MR) scanners. PET/MR AC (MR-AC) approaches aim to develop methods that allow accurate estimation of the linear attenuation coefficients of the tissues and other components located in the PET field of view. MR-AC methods can be divided into 3 categories: segmentation, atlas, and PET based. This review provides a comprehensive list of the state-of-the-art MR-AC approaches and their pros and cons. The main sources of artifacts are presented. Finally, this review discusses the current status of MR-AC approaches for clinical applications. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Neural Computations Mediating One-Shot Learning in the Human Brain

    Science.gov (United States)

    Lee, Sang Wan; O’Doherty, John P.; Shimojo, Shinsuke

    2015-01-01

    Incremental learning, in which new knowledge is acquired gradually through trial and error, can be distinguished from one-shot learning, in which the brain learns rapidly from only a single pairing of a stimulus and a consequence. Very little is known about how the brain transitions between these two fundamentally different forms of learning. Here we test a computational hypothesis that uncertainty about the causal relationship between a stimulus and an outcome induces rapid changes in the rate of learning, which in turn mediates the transition between incremental and one-shot learning. By using a novel behavioral task in combination with functional magnetic resonance imaging (fMRI) data from human volunteers, we found evidence implicating the ventrolateral prefrontal cortex and hippocampus in this process. The hippocampus was selectively “switched” on when one-shot learning was predicted to occur, while the ventrolateral prefrontal cortex was found to encode uncertainty about the causal association, exhibiting increased coupling with the hippocampus for high-learning rates, suggesting this region may act as a “switch,” turning on and off one-shot learning as required. PMID:25919291

  6. Ankle ligamints : comparison of MR arthrography with conventional MR imaging in amputated feet

    International Nuclear Information System (INIS)

    Yoo, Jae Sung; Lee, Sang Yong; Lee, Jeong Min; Han, Young Min; Chung, Kyung Ho; Kim, CHong Soo

    2001-01-01

    To compare magnetic resonance (MR) arthrography with conventional MR imaging in the evaluation of ankle ligaments. Eight freshly amputated human feet underwent conventional MR imaging and MR arthrography. For the former, 1.5-T magnets in the axial, coronal and sagittal planes were used, and T1-weighted sequences were obtained. Following the injection of 6-10 ml of diluted contrast media (Gd-DTPA 1:250), T1-weighted images were obtained in the same positions as conventional MR images. Paired conventional MR imaging and MR arthrography of each ankle ligament were rated on a five-point scale, and to reflect inter-group differences a Wilcoxon singed-rank test was used to compare the different measurements (p<0.05). In two ankles, MR images of the ligaments were correlated with ankle dissection. Anterior and posterior talofibular ligaments were more clearly revealed by MR arthrography than by conventional MR imaging, while calcaneofibular ligaments showed no difference between these two modalities. With regard to deltoid ligaments, visualization of the anterior and posterior tibiotalar ligament was much improved when contrast material was used to outline the ligament's articular aspect. Visualization of the posterior inferior tibiofibular ligament and inferior transverse ligament were also improved when the use of contrast material provided delineation of the articular side of the ligaments and separated them from adjacent bone. In addition, MR arthography was very useful for indentification of the posterior intermalleolar ligament, though its use did not enhance visualization of the calcaneofibular, tibiocalcaneal, spring or tibiospring ligaments. MR arthrography accurately revealed the anatomic details of ankle ligaments, and may therefore be more useful than conventional Mr imaging for evaluation of these structures

  7. [Symptoms, diagnosis and treatment of pancreaticobiliary maljunction associated with congenital cystic dilatation of bile duct].

    Science.gov (United States)

    Funabiki, T; Matsubara, T; Ochiai, M

    1996-08-01

    The concept of congenital biliary dilatation (CBD) was established by Alonso-Lej whose classification has been widely accepted and become a standard. Todani, Komi and several investigators then added additional subclassifications and/or made a proposal of new classification. The trias, abdominal pain, abdominal mass and jaundice, had been characteristically found in these cases, but recently asymptomatic cases are often found. Many reports have shown that the cases with cystic dilation of the biliary duct frequently associated with biliary carcinoma and pancreaticobiliary maljunction (PBM), an anomalous union of pancreatic duct with biliary tree since the Rabbit's first report. Whereas extracorporeal ultrasound and CT scan are minimally invasive diagnostic procedures for these cases, a direct cholangiography, ERCP and PTC are the diagnostic procedures that make a definite diagnosis for the appropriate treatment. Recently, endoscopic ultrasound (EUS), helical CT and magnetic resonance cholangiopan-creatography (MRCP) have drawn an attention since these methods are less invasive than those ever being used. In particular, MRCP will be suitable for the screening of preoperative examination. Whereas cystoduodenostomy used to be performed in the past for these cases, the resection of dilatted bule duct along with the diversion of bile from pancreatic juice should be performed to prevent biliary carcinoma. Cholecystectomy along with the resection of bile duct and the biliary diversion from pancreatic juice should also be performed for cases of PBM without CBD because mutagenicity of bile mixed with pancreatic juice and K-ras point mutation in noncancerous bile duct epithelium in cases of PBM without CBD were demonstrated.

  8. Pancreaticobiliary maljunction and biliary cancer.

    Science.gov (United States)

    Kamisawa, Terumi; Kuruma, Sawako; Tabata, Taku; Chiba, Kazuro; Iwasaki, Susumu; Koizumi, Satomi; Kurata, Masanao; Honda, Goro; Itoi, Takao

    2015-03-01

    Pancreaticobiliary maljunction (PBM) is a congenital malformation in which the pancreatic and bile ducts join anatomically outside the duodenal wall. Japanese clinical practice guidelines on how to deal with PBM were made in 2012, representing a world first. According to the 2013 revision to the diagnostic criteria for PBM, in addition to direct cholangiography, diagnosis can be made by magnetic resonance cholangiopancreatography (MRCP), 3-dimensional drip infusion cholangiography computed tomography, endoscopic ultrasonography (US), or multiplanar reconstruction images by multidetector row computed tomography. In PBM, the common channel is so long that sphincter action does not affect the pancreaticobiliary junction, and pancreatic juice frequently refluxes into the biliary tract. Persistence of refluxed pancreatic juice injures epithelium of the biliary tract and promotes cancer development, resulting in higher rates of carcinogenesis in the biliary tract. In a nationwide survey, biliary cancer was detected in 21.6% of adult patients with congenital biliary dilatation (bile duct cancer, 32.1% vs. gallbladder cancer, 62.3%) and in 42.4% of PBM patients without biliary dilatation (bile duct cancer, 7.3% vs. gallbladder cancer, 88.1%). Pathophysiological conditions due to pancreatobiliary reflux occur in patients with high confluence of pancreaticobiliary ducts, a common channel ≥6 mm long, and occlusion of communication during contraction of the sphincter. Once the diagnosis of PBM is established, immediate prophylactic surgery is recommended. However, the surgical strategy for PBM without biliary dilatation remains controversial. To detect PBM without biliary dilatation early, MRCP is recommended for patients showing gallbladder wall thickening on screening US under suspicion of PBM.

  9. Spontaneous biliary peritonitis: Is bed side diagnosis possible?

    Directory of Open Access Journals (Sweden)

    Vijai Datta Upadhyaya

    2013-01-01

    Full Text Available Background: Spontaneous biliary peritonitis is a rare cause of acute abdomen. In spontaneous biliary peritonitis there is perforation in the wall of the extra-hepatic or intra-hepatic duct occurs without any traumatic or iatrogenic injury and have been described more often in neonates. The symptoms may be acute or insidious delaying the diagnosis. Present manuscript deals with diagnosis and management of these cases. Materials and Methods: This is a prospective study and all patients of suspected biliary peritonitis presented during Dec 2010 to Feb 2012 were included in the study. After preliminary investigations in all patients abdominal paracentesis was done and in cases where intra-abdominal fluid bilirubin level was several fold higher than serum bilirubin level were subjected to exploratory laparotomy. Further investigation like T-tube cholangiogram and magnetic resonance cholangiopancreatography (MRCP was done to rule out choledochal cyst before leveling these cases as SPBD. Results: A total of 6 patients were included in present series commonest presenting symptom was progressive abdominal distension without signs of overt peritonitis followed by progressive jaundice, fever and abdominal pain. On exploration site of perforation was observed in 50% of cases and in 50% of cases bile duct was not dilated. Second surgery was not required in 34% of cases. There was no mortality or significant morbidity in our series. Conclusion: Spontaneous perforation of bile duct is rare disease and high index of suspicion is required for diagnosis. Simple bed side test can help in diagnosis but T tube cholangiogram or MRCP are must to rule out choledochal cyst.

  10. Lower Extremity Muscle Activity During a Women's Overhand Lacrosse Shot

    Directory of Open Access Journals (Sweden)

    Millard Brianna M.

    2014-07-01

    Full Text Available The purpose of this study was to describe lower extremity muscle activity during the lacrosse shot. Participants (n=5 females, age 22±2 years, body height 162.6±15.2 cm, body mass 63.7±23.6 kg were free from injury and had at least one year of lacrosse experience. The lead leg was instrumented with electromyography (EMG leads to measure muscle activity of the rectus femoris (RF, biceps femoris (BF, tibialis anterior (TA, and medial gastrocnemius (GA. Participants completed five trials of a warm-up speed shot (Slow and a game speed shot (Fast. Video analysis was used to identify the discrete events defining specific movement phases. Full-wave rectified data were averaged per muscle per phase (Crank Back Minor, Crank Back Major, Stick Acceleration, Stick Deceleration. Average EMG per muscle was analyzed using a 4 (Phase x 2 (Speed ANOVA. BF was greater during Fast vs. Slow for all phases (p0.05. RF and GA were each influenced by the interaction of Phase and Speed (p<0.05 with GA being greater during Fast vs. Slow shots during all phases and RF greater during Crank Back Minor and Major as well as Stick Deceleration (p<0.05 but only tended to be greater during Stick Acceleration (p=0.076 for Fast vs. Slow. The greater muscle activity (BF, RF, GA during Fast vs. Slow shots may have been related to a faster approach speed and/or need to create a stiff lower extremity to allow for faster upper extremity movements.

  11. Evaluation of cardiac function using multi-shot echo planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, Tadashi; Tanitame, Nobuko; Hata, Ryoichiro; Hirai, Nobuhiko; Ikeda, Midori; Ono, Chiaki; Fukuoka, Haruhito; Ito, Katsuhide [Hiroshima Univ. (Japan). School of Medicine

    1998-01-01

    In this study, we performed multi-shot echo planar imaging (8 shot, TR/TE/FL=55 ms/18 ms/60 degrees) and k-space segmented fast gradient echo sequence (8 views per segment, TR/TE/FL=9.9 ms/1.8 ms/30 degrees) to assess cardiac function in healthy volunteers. Transaxial sections of the entire heart were obtained with both sequences in ECG triggered, breath hold, and with a 256 x 128 matrix. Resulting temporal resolution was 55 ms for echo planar imaging, and 71 ms for k-space segmented fast gradient echo sequence, respectively. Ventricular volume and ejection fraction of both ventricles and left ventricular mass obtained with multi-shot echo planar imaging were assessed in comparison with k-space segmented fast gradient echo sequence. Measurements of left ventricular volume, ejection fraction and mass obtained with multi-shot echo planar imaging demonstrated close correlation with those obtained with k-space segmented fast gradient echo sequence. Right ventricular volumes obtained with echo planar imaging were significantly higher than those obtained with k-space segmented fast gradient echo sequence. This tendency is considered to be due to differing contrast between right ventricular myocardium and fat tissue observed with echo planar imaging relative to that observed with fast gradient echo sequence, because fat suppression is always performed in echo planar images. Multi-shot echo planar imaging can be a reliable tool for measurement of cardiac functional parameters, although wall motion analysis of the left ventricle requires higher temporal resolution and a short axial section. (K.H.)

  12. Effects of Laser Peening, and Shot Peening, on Friction Stir Welding

    Science.gov (United States)

    Hatamleh, Omar; Hackel, Lloyd; Rankin, Jon; Truong, Chanh; Walter, Matt

    2006-01-01

    A viewgraph presentation describing the effects of laser peening and shot peening on friction stir welding is shown. The topics include: 1) Background; 2) Friction Stir Welding (FSW); 3) Microstructure; 4) Laser & Shot Peening; 5) Residual Stresses; 6) Tensile Behavior; 7) Fatigue Life & Surface Roughness; 8) Crack Growth; and 9) Benefits.

  13. Muscular power, neuromuscular activation, and performance in shot put athletes at preseason and at competition period.

    Science.gov (United States)

    Kyriazis, Thomas A; Terzis, Gerasimos; Boudolos, Konstantinos; Georgiadis, Georgios

    2009-09-01

    The aim of this study was to investigate changes in shot put performance, muscular power, and neuromuscular activation of the lower extremities, between the preseason and the competition period, in skilled shot put athletes using the rotational technique. Shot put performance was assessed at the start of the pre-season period as well as after 12 weeks, at the competition period, in nine shot putters. Electromyographic (EMG) activity of the right vastus lateralis muscle was recorded during all shot put trials. Maximum squat strength (1RM) and mechanical parameters during the countermovement jump (CMJ) on a force platform were also determined at pre-season and at competition period. Shot put performance increased 4.7% (p phase was increased significantly (p training period. Shot put performance was significantly related with muscular power and takeoff velocity during the CMJ, at competition period (r = 0.66, p competition period.

  14. Matas test combined with MR flow measurement

    International Nuclear Information System (INIS)

    Isoda, Haruo; Masui, Takayuki; Takahashi, Motoichiro; Mochizuki, Takao; Kaneko, Masao; Ohta, Atsuko; Shirakawa, Toyomi.

    1993-01-01

    Prior to the temporary or permanent therapeutic occlusion of the carotid artery, evaluation of the cerebral collateral circulation via the circle of Willis is necessary in order to prevent complications. The purpose of our study was to evaluate the flow velocity of the contralateral common carotid artery using Renal Time Acquisition and Velocity Evaluation (RACE) before and during a Matas test and to estimate brain collateral circulation. Five normal subjects were studied with a 1.5 T superconducting imager (Siemens, Erlangen) using a neck coil. RACE is a one-dimensional projective flow measurement technique using fast low angle shot (FLASH) without phase encoding gradient (FLASH sequence: TR=20 ms, TE=6 ms, FA=90 degrees, FOV=220 mm, slice thickness=8 mm). The total acquisition time is about 10 seconds without need for electrocardiographic synchronization. Flow velocity of the common carotid artery was evaluated using the RACE technique before and during a Matas test. The relative flow ratio of the contralateral carotid artery (flow velocity during the Matas test divided by that before the Matas test) was calculated. Additionally, using a head coil, 3 dimensional time-flight MR angiograms of the brain were obtained for each subject order to evaluate the anterior communicating artery. Six out of the 10 common carotid arteries were sufficiently compressed to stop blood flow. The relative mean ratio was 1.74 with a standard deviation of 0.36. The anterior communicating artery was visualized in all subjects. Increased blood volume is thus thought to maintain the blood supply of a cerebral hemisphere affected by compression of the common carotid artery via the anterior communicating artery. MR flow measurement using RACE before and during the Matas test seems to be a noninvasive method for evaluating cerebral collateral circulation via the circle of Willis. (author)

  15. Do carotid MR surface coils affect PET quantification in PET/MR imaging?

    International Nuclear Information System (INIS)

    Willemink, Martin J; Eldib, Mootaz; Leiner, Tim; Fayad, Zahi A; Mani, Venkatesh

    2015-01-01

    To evaluate the effect of surface coils for carotid MR imaging on PET quantification in a clinical simultaneous whole-body PET/MR scanner. A cylindrical phantom was filled with a homogeneous 2L water-FDG mixture at a starting dose of 301.2MBq. Clinical PET/MR and PET/CT systems were used to acquire PET-data without a coil (reference standard) and with two carotid MRI coils (Siemens Special Purpose 8-Channel and Machnet 4-Channel Phased Array). PET-signal attenuation was evaluated with Osirix using 51 (PET/MR) and 37 (PET/CT) circular ROIs. Mean and maximum standardized uptake values (SUVs) were quantified for each ROI. Furthermore, SUVs of PET/MR and PET/CT were compared. For validation, a patient was scanned with an injected dose of 407.7MBq on both a PET/CT and a PET/MR system without a coil and with both coils. PET/MR underestimations were -2.2% (Siemens) and -7.8% (Machnet) for SUVmean, and -1.2% (Siemens) and -3.3% (Machnet) for SUVmax, respectively. For PET/CT, underestimations were -1.3% (Siemens) and -1.4% (Machnet) for SUVmean and -0.5% (both Siemens and Machnet) for SUVmax, respectively using no coil data as reference. Except for PET/CT SUVmax values all differences were significant. SUVs differed significantly between PET/MR and PET/CT with SUVmean values of 0.51-0.55 for PET/MR and 0.68-0.69 for PET/CT, respectively. The patient examination showed that median SUVmean values measured in the carotid arteries decreased from 0.97 without a coil to 0.96 (Siemens) and 0.88 (Machnet). Carotid surface coils do affect attenuation correction in both PET/MR and PET/CT imaging. Furthermore, SUVs differed significantly between PET/MR and PET/CT.

  16. Diffusion-weighted MR imaging of neuro-Behcet's disease: initial and follow-up studies

    International Nuclear Information System (INIS)

    Heo, Suk Hee; Seo, Jeong Jin; Kim, Heung Joong; Chang, Nam Gyu; Shin, Sang Soo; Jeong, Yong Yeon; Jeong Gwang Woo; Kang, Heoung Keun

    2005-01-01

    To assess the usefulness of diffusion-weighted MR imaging (DWI) and apparent diffusion coefficient (ADC) in the initial and follow-up studies of patients with neuro-Behcet's disease. Six patients diagnosed with neuro-Behcet's disease were the subjects of this study. Initial and follow-up MR imaging were obtained in all six patients. Initial and follow-up DWI were also obtained is four of the six patients, with only an initial DWI in the other two. The DWI were obtained using multi-shot echo planar imaging, on a 1.5T MR unit, with two gradient steps (b values of 0, 1000 sec/mm 2 ). The ADC value and ADC maps were obtained using commercial software. The locations and signal intensities of the lesions were analyzed on conventional MRI and DWI, respectively. The ADC values of the lesions were calculated on the initial and follow-up DWI, and compared those of lesions in the normal contralateral regions. The initial DWI showed iso-signal intensities in four of the six patients, with high signal intensities in the other two. In five of the six patients, including three of the four that showed isosignal intensities and the two that showed high signal intensities on the initial DWI, the ADC values of the involved lesions were higher than those of the normal contralateral regions. In three of four that showed isosignal intensities, the ADC values of the lesions were decreased and normalized on the follow-up DWI. Obtaining DWI and ADC values in patients with neuro-Behcet's disease may be helpful in the understanding of pathophysiology and differential diagnosis of this disease

  17. Effect of shot peening process on fatigue behavior of an alloyed austempered ductile iron

    Directory of Open Access Journals (Sweden)

    Amir Sadighzadeh Benam

    2011-08-01

    Full Text Available Shot peening is one of the most common surface treatments to improve the fatigue behavior of metallic parts. In this study the effect of shot peening process on the fatigue behavior of an alloyed austempered ductile iron (ADI has been studied. Austempering heat treatment consisted of austenitizing at 875℃ for 90 min followed by austempering at three different temperatures of 320, 365 and 400℃. Rotating-bending fatigue test was carried out on samples after shot peening by 0.4 – 0.6 mm shots. XRD and SEM analysis, micro hardness and roughness tests were carried out to study the fatigue behavior of the samples. Results indicate that the fatigue strengths of samples austempered at 320, 365 and 400℃ are increased by 27.3%, 33.3% and 48.4%, respectively, after shot peening process.

  18. On the residual stress modeling of shot-peened AISI 4340 steel: finite element and response surface methods

    Science.gov (United States)

    Asgari, Ali; Dehestani, Pouya; Poruraminaie, Iman

    2018-02-01

    Shot peening is a well-known process in applying the residual stress on the surface of industrial parts. The induced residual stress improves fatigue life. In this study, the effects of shot peening parameters such as shot diameter, shot speed, friction coefficient, and the number of impacts on the applied residual stress will be evaluated. To assess these parameters effect, firstly the shot peening process has been simulated by finite element method. Then, effects of the process parameters on the residual stress have been evaluated by response surface method as a statistical approach. Finally, a strong model is presented to predict the maximum residual stress induced by shot peening process in AISI 4340 steel. Also, the optimum parameters for the maximum residual stress are achieved. The results indicate that effect of shot diameter on the induced residual stress is increased by increasing the shot speed. Also, enhancing the friction coefficient magnitude always cannot lead to increase in the residual stress.

  19. Shot-noise dominant regime of a nanoparticle in a laser beam

    Science.gov (United States)

    Zhong, Changchun; Robicheaux, Francis

    2017-04-01

    The technique of laser levitation of nanoparticles has become increasingly promising in the study of cooling and controlling mesoscopic quantum systems. Unlike a mechanical system, the levitated nanoparticle is less exposed to thermalization and decoherence due to the absence of direct contact with a thermal environment. In ultrahigh vacuum, the dominant source of decoherence comes from the unavoidable photon recoil from the optical trap which sets an ultimate bound for the control of levitated systems. In this paper, we study the shot noise heating and the parametric feedback cooling of an optically trapped anisotropic nanoparticle in the laser shot noise dominant regime. The rotational trapping frequency and shot noise heating rate have a dependence on the shape of the trapped particle. For an ellipsoidal particle, the ratio of the axis lengths and the overall size controls the shot noise heating rate relative to the rotational frequency. For a near spherical nanoparticle, the effective heating rate for the rotational degrees of freedom is smaller than that for translation suggesting that the librational ground state may be easier to achieve than the vibrational ground state.

  20. Shot Noise in Negative-Differential-Conductance Devices

    National Research Council Canada - National Science Library

    Song, W

    2003-01-01

    The authors have compared the shot-noise properties at T = 4.2 K of a double-barrier resonant-tunneling diode and a superlattice tunnel diode, both of which exhibit negative differential-conductance (NDC...

  1. Mr imaging and mr spectroscopy of brain metastases by mr perfusion

    International Nuclear Information System (INIS)

    Weber, Marc-Andre; Lichy, M.P.; Thilmann, C.; Guenther, M.; Bachert, P.; Delorme, S.; Schad, L.R.; Debus, J.; Schlemmer, H.P.; Maudsley, A.A.

    2003-01-01

    In follow-up examinations of irradiated brain metastases conventional contrast-enhanced morphological MR imaging is often unable to distinguish between transient radiation effects, radionecrosis, and tumor recurrence. To evaluate changes of relative cerebral blood flow (rCBF) in irradiated brain metastases arterial spin-labeling techniques (ASL) were applied and compared to the outcome of 1 H MR spectroscopy and spectroscopic imaging ( 1 H MRS, SI). Patients and methods In 2 patients follow-up examinations of irradiated brain metastases were performed on a 1.5-T tomograph (average single dose: 20 Gy/80% isodose). Relative CBF values of gray matter (GM), white matter (WM), and metastases (Met) were measured by means of the ASL techniques ITS-FAIR and Q2TIPS. 1 H MRS was performed with PRESS 1500/135. In both patients with initially hyperperfused metastases (Met/GM >1) the reduction of rCBF after stereotactic radiosurgery indicated response to treatment - even if the contrast-enhancing region increased - while increasing rCBF values indicated tumor progression. The findings were confirmed by 1 H MRS, SI and subsequent follow-up. The ASL techniques ITS-FAIR and Q2TIPS are able to monitor changes of rCBF in irradiated brain metastases. The two cases imply a possible role for ASL-MR perfusion imaging and 1 H MR spectroscopy in differentiating radiation effects from tumor progression. (orig.) [de

  2. Deep Learning MR Imaging-based Attenuation Correction for PET/MR Imaging.

    Science.gov (United States)

    Liu, Fang; Jang, Hyungseok; Kijowski, Richard; Bradshaw, Tyler; McMillan, Alan B

    2018-02-01

    Purpose To develop and evaluate the feasibility of deep learning approaches for magnetic resonance (MR) imaging-based attenuation correction (AC) (termed deep MRAC) in brain positron emission tomography (PET)/MR imaging. Materials and Methods A PET/MR imaging AC pipeline was built by using a deep learning approach to generate pseudo computed tomographic (CT) scans from MR images. A deep convolutional auto-encoder network was trained to identify air, bone, and soft tissue in volumetric head MR images coregistered to CT data for training. A set of 30 retrospective three-dimensional T1-weighted head images was used to train the model, which was then evaluated in 10 patients by comparing the generated pseudo CT scan to an acquired CT scan. A prospective study was carried out for utilizing simultaneous PET/MR imaging for five subjects by using the proposed approach. Analysis of covariance and paired-sample t tests were used for statistical analysis to compare PET reconstruction error with deep MRAC and two existing MR imaging-based AC approaches with CT-based AC. Results Deep MRAC provides an accurate pseudo CT scan with a mean Dice coefficient of 0.971 ± 0.005 for air, 0.936 ± 0.011 for soft tissue, and 0.803 ± 0.021 for bone. Furthermore, deep MRAC provides good PET results, with average errors of less than 1% in most brain regions. Significantly lower PET reconstruction errors were realized with deep MRAC (-0.7% ± 1.1) compared with Dixon-based soft-tissue and air segmentation (-5.8% ± 3.1) and anatomic CT-based template registration (-4.8% ± 2.2). Conclusion The authors developed an automated approach that allows generation of discrete-valued pseudo CT scans (soft tissue, bone, and air) from a single high-spatial-resolution diagnostic-quality three-dimensional MR image and evaluated it in brain PET/MR imaging. This deep learning approach for MR imaging-based AC provided reduced PET reconstruction error relative to a CT-based standard within the brain compared

  3. ON THE USE OF SHOT NOISE FOR PHOTON COUNTING

    Energy Technology Data Exchange (ETDEWEB)

    Zmuidzinas, Jonas, E-mail: jonas@caltech.edu [Division of Physics, Mathematics, and Astronomy, California Institute Institute of Technology, Pasadena, CA 91125 (United States)

    2015-11-01

    Lieu et al. have recently claimed that it is possible to substantially improve the sensitivity of radio-astronomical observations. In essence, their proposal is to make use of the intensity of the photon shot noise as a measure of the photon arrival rate. Lieu et al. provide a detailed quantum-mechanical calculation of a proposed measurement scheme that uses two detectors and conclude that this scheme avoids the sensitivity degradation that is associated with photon bunching. If correct, this result could have a profound impact on radio astronomy. Here I present a detailed analysis of the sensitivity attainable using shot-noise measurement schemes that use either one or two detectors, and demonstrate that neither scheme can avoid the photon bunching penalty. I perform both semiclassical and fully quantum calculations of the sensitivity, obtaining consistent results, and provide a formal proof of the equivalence of these two approaches. These direct calculations are furthermore shown to be consistent with an indirect argument based on a correlation method that establishes an independent limit to the sensitivity of shot-noise measurement schemes. Furthermore, these calculations are directly applicable to the regime of interest identified by Lieu et al. Collectively, these results conclusively demonstrate that the photon-bunching sensitivity penalty applies to shot-noise measurement schemes just as it does to ordinary photon counting, in contradiction to the fundamental claim made by Lieu et al. The source of this contradiction is traced to a logical fallacy in their argument.

  4. Shot peening of doel 3 plant

    International Nuclear Information System (INIS)

    Slama, G.; Sort, M.

    1985-12-01

    The process implementation for DOEL consisted in: developing tooling and test procedures for an industrial application including ALARA considerations; qualifying process, tooling and procedures using representative conditions (full size mock-up, of steam generator channel head and associated working area); Establishing the reliability of tooling and procedures to comply permanently with the required criteria (chiefly Almen Intensity); and training and qualifying personnel. A variety of tests were performed by FRAMATOME and BELGATOM to qualify the process and characterize its effects on both inside and outside diameters of the tubes. These are: Mg Cl 2 ; 10% caustic tests at high temperature and pressure; tetrathionate; strain gauges and X rays stresses measurements; effects on precracked tubes; Leak tests after shot peening. The operation was performed at Doel in July 1985. Laboratory tests performed on mockups by FRAMATOME and BELGATOM could demonstrate that on tubes without cracks no difference was found between Eddy current signals from tubes shot-peened or not

  5. Improved design and durability of aluminum die casting horizontal shot sleeves

    Science.gov (United States)

    Birceanu, Sebastian

    The design and performance of shot sleeves is critical in meeting the engineering requirements of aluminum die cast parts. Improvement in shot sleeve materials have a major impact on dimensional stability, reproducibility and quality of the product. This investigation was undertaken in order to improve the life of aluminum die casting horizontal shot sleeves. Preliminary pin tests were run to evaluate the soldering, wash-out and thermal fatigue behavior of commercially available materials and coatings. An experimental rig was designed and constructed for shot sleeve configuration evaluation. Fabrication and testing of experimental shot sleeves was based upon preliminary results and manufacturing costs. Three shot sleeve designs and materials were compared to a reference nitrided H13 sleeve. Nitrided H13 is the preferred material for aluminum die casting shot sleeves because of wear resistance, strength and relative good soldering and wash-out resistance. The study was directed towards damage evaluation on the area under the pouring hole. This area is the most susceptible to damage because of high temperatures and impingement of molten aluminum. The results of this study showed that tungsten and molybdenum had the least amount of soldering and wash-out damage, and the best thermal fatigue resistance. Low solubility in molten aluminum and stability of intermetallic layers are main factors that determine the soldering and wash-out behavior. Thermal conductivity and thermal expansion coefficient directly influence thermal fatigue behavior. TiAlN nanolayered coating was chosen as the material with the best damage resistance among several commercial PVD coatings, because of relatively large thickness and simple deposition conditions. The results show that molybdenum thermal sprayed coating provided the best protection against damage under the pouring hole. Improved bonding is however required for life extension of the coating. TiAlN PVD coating applied on H13 nitrided

  6. Microscopic analysis of effect of shot peening on corrosion fatigue behavior of aluminum alloy

    International Nuclear Information System (INIS)

    Kim, Jong Cheon; Cheong, Seong Kyun

    2012-01-01

    The object of this study considers corrosion fatigue improvement of 7075-T6 aluminum by using shot peening treatment on 3.5% NaCl solution at room temperature. Aluminum alloy is generally used in aerospace structural components because of the light weight and high strength characteristics. Many studies have shown that an aluminum alloy can be approximately 50% lighter than other materials. Mostly, corrosion leads to earlier fatigue crack propagation under tensile conditions and severely reduces the life of structures. Therefore, the technique to improve material resistance to corrosion fatigue is required. Shot peening technology is widely used to improve fatigue life and other mechanical properties by induced compressive residual stress. Even the roughness of treated surface causes pitting corrosion, the compressive residual stress, which is induced under the surface layer of material by shot peening, suppersses the corrosion and increases the corrosion resistance. The experimental results for shot peened specimens were compared with previous work for non treated aluminum alloy. The results show that the shot peening treatment affects the corrosion fatigue improvement of aluminum alloys and the induced compressive residual stress by shot peening treatment improves the resistance to corrosion fatigue

  7. Microscopic analysis of effect of shot peening on corrosion fatigue behavior of aluminum alloy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Cheon; Cheong, Seong Kyun [Seoul Nat' l Univ. of Science and Technology, Seoul (Korea, Republic of)

    2012-11-15

    The object of this study considers corrosion fatigue improvement of 7075-T6 aluminum by using shot peening treatment on 3.5% NaCl solution at room temperature. Aluminum alloy is generally used in aerospace structural components because of the light weight and high strength characteristics. Many studies have shown that an aluminum alloy can be approximately 50% lighter than other materials. Mostly, corrosion leads to earlier fatigue crack propagation under tensile conditions and severely reduces the life of structures. Therefore, the technique to improve material resistance to corrosion fatigue is required. Shot peening technology is widely used to improve fatigue life and other mechanical properties by induced compressive residual stress. Even the roughness of treated surface causes pitting corrosion, the compressive residual stress, which is induced under the surface layer of material by shot peening, suppersses the corrosion and increases the corrosion resistance. The experimental results for shot peened specimens were compared with previous work for non treated aluminum alloy. The results show that the shot peening treatment affects the corrosion fatigue improvement of aluminum alloys and the induced compressive residual stress by shot peening treatment improves the resistance to corrosion fatigue.

  8. Evaluation of the 1Shot Phantom dedicated to the mammography system using FCR

    International Nuclear Information System (INIS)

    Nagashima, Chieko; Uchiyama, Nachiko; Moriyama, Noriyuki; Nagata, Mio; Kobayashi, Hiroyuki; Sankoda, Katsuhiro; Saotome, Shigeru; Tagi, Masahiro; Kusunoki, Tetsurou

    2009-01-01

    Currently daily quality control (QC) tests for mammography systems are generally evaluated by using visual analysis phantoms, which of course means subjective measurement. In our study, however, we evaluated a novel digital phantom, the 1Shot Phantom M plus (1Shot Phantom), together with automatic analysis software dedicated for mammography systems using Fuji computed radiography (FCR). The digital phantom enables objective evaluation by providing for actual physical measurement rather than subjective visual assessment. We measured contrast to noise ratio (CNR), image receptor homogeneity, missed tissue at chest wall side, modulation transfer function (MTF), and geometric distortion utilizing the 1Shot Phantom. We then compared the values obtained using the 1Shot Phantom with values obtained from the European guidelines and International Electrotechnical Commission (IEC) standards. In addition, we evaluated the convenience of using the digital phantom. The values utilizing the 1Shot Phantom and those from the European guidelines and IEC standards were consistent, but the QC tests for the European guidelines and IEC standards methods took about six hours while the same QC tests using the 1Shot Phantom took 10 minutes or less including exposure of the phantom image, measurement, and analysis. In conclusion, the digital phantom and dedicated software proved very useful and produced improved analysis for mammography systems using FCR in clinical daily QC testing because of their objectivity and substantial time-saving convenience. (author)

  9. A Shot Parameter Specification Subsystem for automated control of PBFA [Particle Beam Fusion Accelerator] II accelerator shots

    International Nuclear Information System (INIS)

    Spiller, J.L.

    1987-01-01

    The Shot Parameter Specification Subsystem (SPSS) is an integral part of the automatic control system developed for the Particle Beam Fusion Accelerator II (PBFA II) by the Control Monitor (C/M) Software Development Team. This system has been designed to fully utilize the accelerator by tailoring shot parameters to the needs of the experimenters. The SPSS is the key to this flexibility. Automatic systems will be required on many pulsed power machines for the fastest turnaround, the highest reliability, and most cost effective operation. These systems will require the flexibility and the ease of use that is part of the SPSS. The PBFA II control system has proved to be an effective modular system, flexible enough to meet the demands of both the fast track construction of PBFA II and the control needs of Hermes III at the Simulation Technology Laboratory. This system is expected to meet the demands of most future machine changes

  10. MR enterography sequence evaluation for patients with Crohn's disease; Sequenz-Evaluation fuer die MR-Enterografie fuer Patienten mit Morbus Crohn

    Energy Technology Data Exchange (ETDEWEB)

    Schleder, S.; Dendle, L.M.; Friedrich, C.; Wiggermann, P.; Stroszczynski, C.; Schreyer, A.G. [Universitaetsklinikum Regensburg (Germany). Inst. fuer Roentgendiagnostik; Pawlik, M. [Caritas-Krankenhaus St. Josef, Regensburg (Germany). Klinik fuer Anaesthesiologie, Intensiv- und Notfallmedizin; Ott, C. [Universitaetsklinikum Regensburg (Germany). Klinik und Poliklinik fuer Innere Medizin I; Agha, A. [Universitaetsklinikum Regensburg (Germany). Klinik und Poliklinik fuer Chirurgie

    2013-05-15

    Purpose: To evaluate a routine MR enterography (MRE) protocol for patients with Crohn's disease (CD) in order to assess and rank the subjectively most important sequences regarding diagnostic decisions. Materials and Methods: We prospective ly examined 84 patients (42 male) with known CD using a coronal T2/T1-weighted balanced SSFP (TrueFISP), axial T2-weighted single shot TSE (HASTE) as well as an axial T1-weighted gradient-echo sequence (2D-FLASH) before intravenous contrast application and a 2D-FLASH sequence with axial and coronal orientation after in travenous contrast application. 4 experienced radiologists subjectively evaluate d the sequences independently using a scale between 1 and 5 (1 = excellent; 5 = non-diagnostic) regarding their diagnostic significance for a final radiologic d ecision. The ranking of the different sequences was statistically tested by the Friedman analysis. Results: The following ranking was found: HASTE sequences wer e ranked prior to contrast-enhanced axial gradient-echo (2D-FLASH). The third to fifth ranking was TrueFISP, the axial contrast-enhanced 2D-FLASH and the 2D-FLA SH without contrast, respectively. Differences between the first and second rank were significant (p < 0.05), and all other differences were highly significant (p < 0.01). Conclusion: The stable and fast T2-weighted MR sequences without intravenous contrast represented by axial HASTE and coronal TrueFISP were ranked as number 1 and 3. The examination protocol should be completed by a coronal T 1-weighted gradient-echo-sequence after contrast injection, which can be supplemented by an axial acquisition. The T1-weighted gradient-echo sequence without contrast could be omitted. (orig.)

  11. Pumped shot noise in adiabatically modulated graphene-based double-barrier structures.

    Science.gov (United States)

    Zhu, Rui; Lai, Maoli

    2011-11-16

    Quantum pumping processes are accompanied by considerable quantum noise. Based on the scattering approach, we investigated the pumped shot noise properties in adiabatically modulated graphene-based double-barrier structures. It is found that compared with the Poisson processes, the pumped shot noise is dramatically enhanced where the dc pumped current changes flow direction, which demonstrates the effect of the Klein paradox.

  12. Pumped shot noise in adiabatically modulated graphene-based double-barrier structures

    Science.gov (United States)

    Zhu, Rui; Lai, Maoli

    2011-11-01

    Quantum pumping processes are accompanied by considerable quantum noise. Based on the scattering approach, we investigated the pumped shot noise properties in adiabatically modulated graphene-based double-barrier structures. It is found that compared with the Poisson processes, the pumped shot noise is dramatically enhanced where the dc pumped current changes flow direction, which demonstrates the effect of the Klein paradox.

  13. MR imaging of prostate cancer; MR-Tomographie des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Heuck, A.; Scheidler, J.; Sommer, B.; Graser, A. [Radiologisches Zentrum Muenchen-Pasing (Germany); Mueller-Lisse, U.G. [Institut fuer Klinische Radiologie, Universitaet Muenchen (Germany); Massmann, J. [Gemeinschaftspraxis Pathologie, Muenchen (Germany)

    2003-06-01

    Accurate diagnosis and staging of prostate cancer (PC) is developing into an important health care issue in light of the high incidence of PC and the improvements in stage-adapted therapy. The purpose of this paper is to provide an overview on the current role of MR imaging and MR spectroscopy in the diagnosis and staging of PC.Material and methods Pertinent literature was searched and evaluated to collect information on current clinical indications, study techniques, diagnostic value, and limitations of magnetic resonance imaging and spectroscopy. Major indications for MR imaging of patients with supected PC are to define tumor location before biopsy when clinical or TRUS findings are inconclusive, and to provide accurate staging of histologically proven PC to ascertain effective therapy. Current MR imaging techniques for the evaluation of PC include multiplanar high-resolution T2-weighted FSE and T1-weighted SE sequences using combined endorectal and phased-array coils. Using these techniques, the reported accuracy of MR imaging for the diagnosis of extracapsular tumor extension ranges between 82 and 88% with sensitivities between 80 and 95%, and specificities between 82 and 93%. Typical MR findings of PC in different stages of disease, as well as diagnostic problems, such as chronic prostatitis, biopsy-related hemorrhage and therapy-related changes of prostatic tissue are discussed. In addition, the current perspectives and limitations of MR spectroscopy in PC are summarized. Current MR imaging techniques provide important diagnostic information in the pretherapeutic workup of PC including a high staging accuracy, and is superior to TRUS. (orig.) [German] Der Diagnostik des Prostatakarzinoms kommt wegen seiner hohen Inzidenz und den verbesserten stadienadaptierten Therapiemoeglichkeiten eine grosse Bedeutung zu. Dabei spielen bildgebende Verfahren bei den klinisch oft unzureichend diagnostizierbaren Faellen eine wesentliche Rolle fuer die praetherapeutische

  14. Shot noise of a quantum shuttle

    DEFF Research Database (Denmark)

    Novotny, Tomas; Donarini, Andrea; Flindt, Christian

    2004-01-01

    We formulate a theory for shot noise in quantum nanoelectromechanical systems. As a specific example, the theory is applied to a quantum shuttle, and the zero-frequency noise, measured by the Fano factor F, is computed. F reaches very low values (Fsimilar or equal to10(-2)) in the shuttling regim...

  15. Kinematic Differences between Set- and Jump-Shot Motions in Basketball

    OpenAIRE

    Hiroki Okubo; Mont Hubbard

    2018-01-01

    Shooting arm motions at release in one-hand set and jump basketball shots have been analyzed using a kinematic model. Set and jump shots are classified by the vertical velocity and acceleration of the shooter’s shooting-side shoulder at release. The two-dimensional three-segment model includes the vertical shooting-side shoulder velocity and acceleration. Numerical simulation investigates the effect of shoulder motion. Release backspin angular velocity can be described as a function of the ve...

  16. On the Path to SunShot - Executive Summary

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2016-05-01

    The halfway mark of the SunShot Initiative’s 2020 target date is a good time to take stock: How much progress has been made? What have we learned? What barriers and opportunities must still be addressed to ensure that solar technologies achieve cost parity in 2020 and realize their full potential in the decades beyond? To answer these questions, the Solar Energy Technology Office launched the On the Path to SunShot series in early 2015 in collaboration with the National Renewable Energy Laboratory (NREL) and with contributions from Lawrence Berkeley National Laboratory (LBNL), Sandia National Laboratories (SNL), and Argonne National Laboratory (ANL). The reports focus on the areas of technology development, systems integration, and market enablers.

  17. Interventional MR: vascular applications.

    Science.gov (United States)

    Smits, H F; Bos, C; van der Weide, R; Bakker, C J

    1999-01-01

    Three strategies for visualisation of MR-dedicated guidewires and catheters have been proposed, namely active tracking, the technique of locally induced field inhomogeneity and passive susceptibility-based tracking. In this article the pros and cons of these techniques are discussed, including the development of MR-dedicated guidewires and catheters, scan techniques, post-processing tools, and display facilities for MR tracking. Finally, some of the results obtained with MR tracking are discussed.

  18. The effect of shot peening on notched low cycle fatigue

    International Nuclear Information System (INIS)

    Soady, K.A.; Mellor, B.G.; Shackleton, J.; Morris, A.; Reed, P.A.S.

    2011-01-01

    Highlights: → Shot peening improves notched component three point bend low cycle fatigue life. → Notch shape does not affect the efficacy of the peening process. → Strain hardening and residual stress effects need separate consideration. → Loading direction residual stresses do not relax under bend load. - Abstract: The improvement in low cycle fatigue life created by shot peening ferritic heat resistant steel was investigated in components of varying geometries based on those found in conventional power station steam turbine blades. It was found that the shape of the component did not affect the efficacy of the shot peening process, which was found to be beneficial even under the high stress amplitude three point bend loads applied. Furthermore, by varying the shot peening process parameters and considering fatigue life it has been shown that the three surface effects of shot peening; roughening, strain hardening and the generation of a compressive residual stress field must be included in remnant life models as physically separate entities. The compressive residual stress field during plane bending low cycle fatigue has been experimentally determined using X-ray diffraction at varying life fractions and found to be retained in a direction parallel to that of loading and to only relax to 80% of its original magnitude in a direction orthogonal to loading. This result, which contributes to the retention of fatigue life improvement in low cycle fatigue conditions, has been discussed in light of the specific stress distribution applied to the components. The ultimate aim of the research is to apply these results in a life assessment methodology which can be used to justify a reduction in the length of scheduled plant overhauls. This will result in significant cost savings for the generating utility.

  19. Shot Boundary Detection in Soccer Video using Twin-comparison Algorithm and Dominant Color Region

    Directory of Open Access Journals (Sweden)

    Matko Šarić

    2008-06-01

    Full Text Available The first step in generic video processing is temporal segmentation, i.e. shot boundary detection. Camera shot transitions can be either abrupt (e.g. cuts or gradual (e.g. fades, dissolves, wipes. Sports video is one of the most challenging domains for robust shot boundary detection. We proposed a shot boundary detection algorithm for soccer video based on the twin-comparison method and the absolute difference between frames in their ratios of dominant colored pixels to total number of pixels. With this approach the detection of gradual transitions is improved by decreasing the number of false positives caused by some camera operations. We also compared performances of our algorithm and the standard twin-comparison method.

  20. Detectability of hepatocellular carcinoma: comparison of Gd-DTPA-enhanced and SPIO-enhanced MR imaging

    International Nuclear Information System (INIS)

    Kwak, Hyo Sung; Lee, Jeong Min; Kim In Hwan; Kim, Chong Soo; Han, Hyeun Young; Yoon, Kwon ha; Shin, Kyung Sook

    2000-01-01

    To compare the detectability of hepatocellular carcinoma (HCC) using superparamagnetic iron oxide (SPIO)-enhanced T2-weighted turbo spin echo (TSE), SPIO-enhanced T2-weighted FISP, and dynamic Gd-DTPA-enhanced fast low-angle shot (FLASH) MR images. In order to assess their hepatic lesions, 25 patients (20 men and 5 women) with HCC were enrolled in an MR study in which both gadolinium and Spiro were used. Since the lesions were most conspicuous during the phase of dynamic arterial dominant phase of dynamic gadolinium-enhanced imaging, this was the phase used for analysis. Images were analyzed qualitatively and quantitatively, and to compare the diagnostic value of gadolinium-enhanced imaging with that of SPIO-enhanced imaging for the detection of HCCs, a receiver-operated characteristic curve was obtained. Qualitative analysis revealed a significantly higher percentage of signal loss and a higher liver-lesion contrast-to-noise ratio on SPIO-enhanced FISP imaging than on SPIO-enhanced T2-weighted TSE imaging (p less than 0.05). It also showed that the lesions were most clearly visible on SPIO-enhanced FISP imaging (and significantly so), followed by SPIO-enhanced T2-weighted TSE imaging, and dynamic gadolinium-enhanced imaging. Imaging artifacts were more prominent on SPIO-enhanced T2-weighted TSE than on SPIO-enhanced PISF imaging or dynamic gadolinium-enhanced imaging (p less than 0.05). According to ROC analysis, SPIO-enhanced T2-weighted turbo spin echo (TSE) or SPIO-enhanced FISP imaging achieved higher accuracy than did dynamic gadolinium-enhanced FLASH imaging (p less than 0.05). For the detection of hepatocellular carcinomas, SPIO-enhanced MR imaging is better than gadolinium-enhanced FLASH imaging

  1. MR anatomy of the joints: an MR-cadaveric correlative study: part I. wrist

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Heung Sik [Seoul National University College of Medicine, Seoul (Korea, Republic of); Donald Resnick [University of California, San Diego (United States)

    1991-07-15

    To acquire the anatomic information necessary for correct interpretation of MR images of the wrist, transverse, coronal, and sagittal MR images of 3 fresh cadaveric wrists were obtained and, subsequently, sectioned along the MR imaging planes. For the precise correlation of anatomic features depicted with MR and with specimen section, cadaveric wrists were fixed in a rectangular cardboard box using paraffin and frozen after MR imaging. High contrast and spatial resolution enabled delineation of small structures including tendons, nerves, vessels, and ligaments, as well as osseous structures. Transverse images provided the best delineation of the carpal tunnel, tendons, nerves, and vessels. Coronal images permitted optimal visualization of triangular fibrocartilage and lunotriquetral and scapholunate ligaments. We conclude that MR imaging accurately and reliably displays the anatomy of the wrist.

  2. PET/MR in oncology: an introduction with focus on MR and future perspectives for hybrid imaging

    Science.gov (United States)

    Balyasnikova, Svetlana; Löfgren, Johan; de Nijs, Robin; Zamogilnaya, Yanna; Højgaard, Liselotte; Fischer, Barbara M

    2012-01-01

    After more than 20 years of research, a fully integrated PET/MR scanner was launched in 2010 enabling simultaneous acquisition of PET and MR imaging. Currently, no clinical indication for combined PET/MR has been established, however the expectations are high. In this paper we will discuss some of the challenges inherent in this new technology, but focus on potential applications for simultaneous PET/MR in the field of oncology. Methods and tracers for use with the PET technology will be familiar to most readers of this journal; thus this paper aims to provide a short and basic introduction to a number of different MRI techniques, such as DWI-MR (diffusion weighted imaging MR), DCE-MR (dynamic contrast enhanced MR), MRS (MR spectroscopy) and MR for attenuation correction of PET. All MR techniques presented in this paper have shown promising results in the treatment of patients with solid tumors and could be applied together with PET increasing the amount of information about the tissues of interest. The potential clinical benefit of applying PET/MR in staging, radiotherapy planning and treatment evaluation in oncology, as well as the research perspectives for the use of PET/MR in the development of new tracers and drugs will be discussed. PMID:23145362

  3. Transfer of mechanical energy during the shot put

    Directory of Open Access Journals (Sweden)

    Błażkiewicz Michalina

    2016-09-01

    Full Text Available The aim of this study was to analyse transfer of mechanical energy between body segments during the glide shot put. A group of eight elite throwers from the Polish National Team was analysed in the study. Motion analysis of each throw was recorded using an optoelectronic Vicon system composed of nine infrared camcorders and Kistler force plates. The power and energy were computed for the phase of final acceleration of the glide shot put. The data were normalized with respect to time using the algorithm of the fifth order spline and their values were interpolated with respect to the percentage of total time, assuming that the time of the final weight acceleration movement was different for each putter. Statistically significant transfer was found in the study group between the following segments: Right Knee – Right Hip (p = 0.0035, Left Hip - Torso (p = 0.0201, Torso – Right Shoulder (p = 0.0122 and Right Elbow – Right Wrist (p = 0.0001. Furthermore, the results of cluster analysis showed that the kinetic chain used during the final shot acceleration movement had two different models. Differences between the groups were revealed mainly in the energy generated by the hips and trunk.

  4. Shot noise as a probe of spin-correlated transport through single atoms

    Science.gov (United States)

    Pradhan, S.; Fransson, J.

    2018-03-01

    We address the shot noise in the tunneling current through a local spin, pertaining to recent experiments on magnetic adatoms and single molecular magnets. We show that both uncorrelated and spin-correlated scattering processes contribute vitally to the noise spectrum. The spin-correlated scattering processes provide an additional contribution to the Landauer-Büttiker shot noise expression, accounting for correlations between the tunneling electrons and the localized spin moment. By calculating the Fano factor, we show that both super- and sub-Poissonian shot noise can be described within our approach. Our theory provides transparent insights into noise spectroscopy, consistent with recent experiments using local probing techniques on magnetic atoms.

  5. Feature Selection Methods for Zero-Shot Learning of Neural Activity

    Directory of Open Access Journals (Sweden)

    Carlos A. Caceres

    2017-06-01

    Full Text Available Dimensionality poses a serious challenge when making predictions from human neuroimaging data. Across imaging modalities, large pools of potential neural features (e.g., responses from particular voxels, electrodes, and temporal windows have to be related to typically limited sets of stimuli and samples. In recent years, zero-shot prediction models have been introduced for mapping between neural signals and semantic attributes, which allows for classification of stimulus classes not explicitly included in the training set. While choices about feature selection can have a substantial impact when closed-set accuracy, open-set robustness, and runtime are competing design objectives, no systematic study of feature selection for these models has been reported. Instead, a relatively straightforward feature stability approach has been adopted and successfully applied across models and imaging modalities. To characterize the tradeoffs in feature selection for zero-shot learning, we compared correlation-based stability to several other feature selection techniques on comparable data sets from two distinct imaging modalities: functional Magnetic Resonance Imaging and Electrocorticography. While most of the feature selection methods resulted in similar zero-shot prediction accuracies and spatial/spectral patterns of selected features, there was one exception; A novel feature/attribute correlation approach was able to achieve those accuracies with far fewer features, suggesting the potential for simpler prediction models that yield high zero-shot classification accuracy.

  6. MR angiography, MR imaging and proton MR spectroscopy in-vivo assessment of skeletal muscle ischemia in diabetic rats.

    Directory of Open Access Journals (Sweden)

    Stefano Delli Pizzi

    Full Text Available To prospectively evaluate the feasibility of using magnetic resonance (MR techniques for in-vivo assessing a rat diabetic model of limb ischemia. Unilateral hind limb ischemia was induced by ligation of the iliac-femoral artery in male streptozotocin-treated and non-diabetic control rats. Four weeks after ligation, rats underwent MR Angiography (MRA, T(1-weighted and Short Time Inversion Recovery (STIR sequences and muscle Proton MR Spectroscopy ((1H-MRS on both hind limbs. After MR examinations, immunoblotting and immunofluorescence analysis were performed. MRA showed a signal void due to flow discontinuation distal to the artery ligation. T(1-weighted and STIR images showed, respectively, the presence of tissue swelling (p = 0.018 for non-diabetic; p = 0.027 for diabetic rats and signal hyperintensity in tissue affected by occlusion. Mean total creatine/water for the occluded limb was significantly lower than for the non-occluded limbs in both non-diabetic (5.46×10(-4 vs 1.14×10(-3, p = 0.028 and diabetic rats (1.37×10(-4 vs 1.10×10(-3; p = 0.018. MR Imaging and (1H-MRS changes were more pronounced in diabetic than in non-diabetic occluded limbs (p = 0.032. MR findings were confirmed by using histological findings. Combined MR techniques can be used to demonstrate the presence of structural and metabolic changes produced by iliac-femoral artery occlusion in rat diabetic model of limb ischemia.

  7. Berry phase and shot noise for spin-polarized and entangled electrons

    International Nuclear Information System (INIS)

    Wang Pei; Tang Weihua; Lu Dinghui; Jiang Lixia; Zhao Xuean

    2007-01-01

    Shot noise for entangled and spin-polarized states in a four-probe geometric setup has been studied by adding two rotating magnetic fields in an incoming channel. Our results show that the noise power oscillates as the magnetic fields vary. The singlet, entangled triplet and polarized states can be distinguished by adjusting the magnetic fields. The Berry phase can be derived by measuring the shot noise power

  8. Effects of shot peening on the residual stress of welded SS400 steel

    International Nuclear Information System (INIS)

    Lee, Jong Man; Kim, Tae Hyung; Cheong, Seong Kyun; Lee, Seung Ho

    2002-01-01

    The fatigue life of structures is usually determined by welding zone. The tensile residual stress, which is induced by welding, reduces the fatigue life and fatigue strength of welded structures. If we remove the tensile residual stress or induce the compressive residual stress, the fatigue life of welded structures will be improved. The change of hardness and compressive residual stress of welded zone after shot peening was investigated in this paper. The results show that the hardness was increased by shot peening. The residual stress was reduced by shot peening

  9. MR and MR arthrography to identify degenerative and posttraumatic diseases in the shoulder joint

    International Nuclear Information System (INIS)

    Lee, Shi-Uk; Lang, Philipp

    2000-01-01

    MR imaging provides a comprehensive evaluation of a wide spectrum of both intraarticular and extraarticular pathology of the shoulder. MR imaging enables the detection or exclusion of degenerative and posttraumatic diseases of the shoulder with a reasonable accuracy. MR arthrography is useful in the visualization of subtle anatomic details and further improves the differentiation. In this article, findings of MR imaging and MR arthrography of degenerative and posttraumatic shoulder diseases (impingement syndrome, rotator cuff tears, and glenohumeral instability) has been reviewed

  10. MR evaluation of CSF fistulae

    International Nuclear Information System (INIS)

    Gupta, V.; Goyal, M.; Mishra, N.; Gaikwad, S.; Sharma, A.

    1997-01-01

    Purpose: To evaluate the role of MR imaging in the localisation of cerebrospinal fluid (CSF) fistulae. Material and Methods: A total of 36 consecutive unselected patients with either clincally proven CSF leakage (n=26) or suspected CSF fistula (n=10) were prospectively evaluated by MR. All MR examinations included fast spin-echo T2-weighted images in the 3 orthogonal planes. Thin-section CT was performed following equivocal or negative MR examination. MR and CT findings were correlated with surgical results in 33 patients. Results: CSF fistula was visualised as a dural-bone defect with hyperintense fluid signal continuous with that in the basal cisterns on T2-weighted images. MR was positive in 26 cases, in 24 of which the fistula was confirmed surgically. In 2 patients the CSF leakage was directly demonstrated on MR. MR sensitivity of 80% compared favourably with the reported 46-81% of CT cisternography (CTC). No significant difference in MR sensitivity in detecting CSF fistula was found between active and inactive leaks. (orig.)

  11. Gaze Embeddings for Zero-Shot Image Classification

    NARCIS (Netherlands)

    Karessli, N.; Akata, Z.; Schiele, B.; Bulling, A.

    2017-01-01

    Zero-shot image classification using auxiliary information, such as attributes describing discriminative object properties, requires time-consuming annotation by domain experts. We instead propose a method that relies on human gaze as auxiliary information, exploiting that even non-expert users have

  12. Three-dimensional coronary MR angiography with continuous administration of Gd-DTPA. Delineation and detection of coronary artery stenosis

    International Nuclear Information System (INIS)

    Yokoyama, Kenichi

    1999-01-01

    Three-dimensional coronary MR angiography (3D coronary MRA) with Gd-DTPA administration was performed in 19 patients to evaluate the vascular delineation and diagnostic capability for stenotic lesions. A 3D fast low-angle shot (FLASH) with a navigator echo respiratory gating technique was used with a superconducting 1.5 tesla MR system (Vision, Siemens Medical Systems, Erlangen, Germany). Administration of the conventional T 1 contrast agent with extra-cellular distribution produced a significant increase in the SNR and CNR of the proximal coronary arterial images. Visual score of both the source images and the multiplanar reconstruction (MPR) images assessed by three radiologists was superior to those on control images (without contrast enhancement). The MRA findings of stenotic lesions of the coronary artery were compared with the results of the conventional coronary angiographic study. Overall sensitivity and specificity for the detection of stenosis were almost the same as those of control images. In conclusion, 3D coronary MRA with Gd-DTPA administration improved coronary artery delineation. However, further technical improvements are required to enhance the value of the technique in detecting stenoses. (author)

  13. Using deep neural networks to augment NIF post-shot analysis

    Science.gov (United States)

    Humbird, Kelli; Peterson, Luc; McClarren, Ryan; Field, John; Gaffney, Jim; Kruse, Michael; Nora, Ryan; Spears, Brian

    2017-10-01

    Post-shot analysis of National Ignition Facility (NIF) experiments is the process of determining which simulation inputs yield results consistent with experimental observations. This analysis is typically accomplished by running suites of manually adjusted simulations, or Monte Carlo sampling surrogate models that approximate the response surfaces of the physics code. These approaches are expensive and often find simulations that match only a small subset of observables simultaneously. We demonstrate an alternative method for performing post-shot analysis using inverse models, which map directly from experimental observables to simulation inputs with quantified uncertainties. The models are created using a novel machine learning algorithm which automates the construction and initialization of deep neural networks to optimize predictive accuracy. We show how these neural networks, trained on large databases of post-shot simulations, can rigorously quantify the agreement between simulation and experiment. This work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  14. Normal anatomy and MR findings of fetal main organs at MR imaging

    International Nuclear Information System (INIS)

    Xia Liming; Zou Mingli; Feng Dingyi; Hu Junwu; Qi Jianpin; Wang Chengyuan

    2005-01-01

    Objective: To investigate normal anatomy and MR findings of fetal main organs. Methods: Forty-seven fetus underwented fast MR imaging, SSFSE sequence was used, the normal anatomy and MR findings of fetal main organs was observed in different gestational age. The organs included: brain, lungs, heart, liver, spleen, gastrointestinal tract, urinary collecting systems, bladder, bones, spine, and subcutaneous fat. Results: Results of MR in 47 fetus showed that the main organs had developed by 20-week-old fetus, about 20 weeks gestation, cerebral cortical surface was smooth, no cortical gyri and sulci, then cortical gyri and sulci developed slowly. The lungs, trachea, bronchus, gastrointestinal tract, renal collecting system and bladder showed high signal intensity; the heart, great vessels, liver, spleen, bones and muscles appeared hypointense; the kidneys appeared isointense, the spine had developed and subcutaneous fat was seen in 20-week-old fetus, the subcutaneous fat increased with fetus maturating. Conclusion: Normal anatomy and MR findings of fetal main organs were clearly showed by fast MR imaging, and they are different from the newborns. (authors)

  15. Treatment of Duodenal Duplication by Trans-umbilical Exploratory Minimal Laparotomy

    Directory of Open Access Journals (Sweden)

    Li-Lan Chiang

    2009-08-01

    Full Text Available Duodenal duplication cysts are rare congenital lesions. Their presentation is often non-specific and physical examination and laboratory studies usually reveal no abnormal findings. The diagnosis of duodenal duplication cysts can thus be challenging and relies on ultrasonography, barium swallow, contrast enhanced computed tomography (CT, magnetic resonance imaging (MRI, and magnetic resonance cholangiopancreatography (MRCP. The management of duodenal duplication cyst is surgical. Laparotomy is usually necessary, and complete resection is the management goal. Subtotal excision with stripping of the mucosa due to close involvement of the pancreatobiliary tree, and endoscopic resection have Duodenal duplication cysts are rare congenital lesions usually diagnosed in infancy, although they may present in adulthood. Prenatal diagnosis is difficult, and postnatal diagnosis relies on ultrasonography, barium swallow, contrast-enhanced computerized tomography, magnetic resonance imaging (MRI, and magnetic resonance cholangiopancreatography. A female newborn was diagnosed with an abdominal cyst (size around 6 ×; 5 × 4 cm at gestational age (GA 24 weeks, by regular prenatal examination. After her birth at GA 37 weeks, we performed abdominal ultrasonography and MRI, but there was no definite diagnosis. The usual management of an abdominal cyst involves resection by laparotomy (requiring a large incision or laparoscopy (requiring several small incisions. We performed an exploratory trans-umbilical minimal laparotomy excision for surgery, and the pathology revealed duodenal duplication. In our case, there was no recurrence of the cyst after 18 months follow-up, and the operation scar was almost undetectable. Trans-umbilical minimal laparotomy excision may be considered as an alternative choice for the management of abdominal and duodenal duplication cysts.

  16. Biliary and pancreatic stenting: Devices and insertion techniques in therapeutic endoscopic retrograde cholangiopancreatography and endoscopic ultrasonography

    Science.gov (United States)

    Mangiavillano, Benedetto; Pagano, Nico; Baron, Todd H; Arena, Monica; Iabichino, Giuseppe; Consolo, Pierluigi; Opocher, Enrico; Luigiano, Carmelo

    2016-01-01

    Stents are tubular devices made of plastic or metal. Endoscopic stenting is the most common treatment for obstruction of the common bile duct or of the main pancreatic duct, but also employed for the treatment of bilio-pancreatic leakages, for preventing post- endoscopic retrograde cholangiopancreatography pancreatitis and to drain the gallbladder and pancreatic fluid collections. Recent progresses in techniques of stent insertion and metal stent design are represented by new, fully-covered lumen apposing metal stents. These stents are specifically designed for transmural drainage, with a saddle-shape design and bilateral flanges, to provide lumen-to-lumen anchoring, reducing the risk of migration and leakage. This review is an update of the technique of stent insertion and metal stent deployment, of the most recent data available on stent types and characteristics and the new applications for biliopancreatic stents. PMID:26862364

  17. Duopoly Market Analysis within One-Shot Decision Framework with Asymmetric Possibilistic Information

    Directory of Open Access Journals (Sweden)

    Peijun Guo

    2010-12-01

    Full Text Available In this paper, a newly emerging duopoly market with a short life cycle is analyzed. The partially known information of market is characterized by the possibility distribution of the parameter in the demand function. Since the life cycle of the new product is short, how many products should be produced by two rival firms is a typical one-shot decision problem. Within the one-shot decision framework, the possibilistic Cournot equilibrium is obtained for the optimal production level of each firm in a duopoly market with asymmetrical possibilistic information. The analysis results show that the proposed approaches are reasonable for one-shot decision problems, which are extensively encountered in business and economics.

  18. MR imaging of articular cartilage; Gelenkknorpel in der MR-Tomographie

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, F.K.W.; Muhle, C.; Heller, M.; Brossmann, J. [Kiel Univ. (Germany). Klinik fuer Diagnostische Radiologie

    2001-04-01

    MR imaging has evolved to the best non-invasive method for the evaluation of articular cartilage. MR imaging helps to understand the structure and physiology of cartilage, and to diagnose cartilage lesions. Numerous studies have shown high accuracy and reliability concerning detection of cartilage lesions and early changes in both structure and biochemistry. High contrast-to-noise ratio and high spatial resolution are essential for analysis of articular cartilage. Fat-suppressed 3D-T{sub 1} weighted gradient echo and T{sub 2}-weighted fast spin echo sequences with or without fat suppression are recommended for clinical routine. In this article the anatomy and pathology of hyaline articular cartilage and the complex imaging characteristics of hyaline cartilage will be discussed. (orig.) [German] Die MR-Tomographie hat sich zur besten nichtinvasiven bildgebenden Methode fuer die Untersuchung von Gelenkknorpel entwickelt. Die MR-Tomographie liefert einen Beitrag zum Verstaendnis der Knorpelstruktur und der Physiologie sowie zur Diagnostik von Knorpelschaeden. Zahlreiche MR-Studien konnten eine hohe Genauigkeit und Zuverlaessigkeit bei der Detektion chondraler Laesionen sowie frueher Veraenderungen struktureller und biochemischer Natur zeigen. Neben einem hohen Kontrast/Rausch-Verhaeltnis ist fuer die Gelenkknorpelanalyse eine hohe raeumliche Aufloesung erforderlich. Im klinischen Routinebetrieb empfehlen sich fuer die Erkennung von Knorpellaesionen besonders fettunterdrueckte 3D-T{sub 1}-gewichtete Gradientenecho- und T{sub 2}-gewichtete Fastspinecho-Sequenzen mit oder ohne Fettunterdrueckung. Die vorliegende Arbeit geht auf die Anatomie und Pathologie des hyalinen Gelenkknorpels ein und diskutiert das komplexe MR-Signalverhalten. (orig.)

  19. Efficacy and safety of endoscopic retrograde cholangiopancreatography in aged and elderly geriatric patients to treat acute cholecystitis

    Directory of Open Access Journals (Sweden)

    GAO Feng

    2013-03-01

    Full Text Available ObjectiveTo retrospectively evaluate the therapeutic efficacy and safety of endoscopic retrograde cholangiopancreatography (ERCP for treating acute cholecystitis in geriatric patients 75 years and older in age. MethodsThe clinical records of our institute were searched to identify aged (75-84 years old and elderly (85 years and older patients who underwent ERCP between January 2008 and December 2012 for new or long-term cholecystitis. The cholecystitis was clinically characterized as acute attack time(s of one to five days and diagnosis was confirmed by imaging analysis (including abdominal ultrasound, computed tomography, and/or magnetic resonance cholangiopancreatography. All surgeries were carried out with the endoscopic nasogallbladder drainage (ENGBD procedure. Postoperative symptoms (such as abdominal pain and fever and clinical findings (such as C-reactive protein (CRP level, imaging findings, and bile drainage volume and consistency were recorded, along with follow-up data of outcome and symptomology, for summary evaluation. ResultsA total 24 patients, including 13 men and 11 women between the ages of 75 and 88 (mean: 81.00±3.23 years, underwent ERCP examination. The cases included general cholecystitis (75.0%, n=18 and acalculous cholecystitis (25.0%, n=6. In addition, 13 (54.2% cases had biliary stones and two (8.3% cases had bile pancreatitis. The ENGBD tube was successfully inserted into the gallbladder in all cases. Twenty-one (87.5% patients experienced relief of abdominal pain and fever within 24 h of the surgery. CRP level decreased to normal for all (100% patients within six days of the surgery. Two (8.3% patients experienced hyperamylasemia within three days of the surgery, and both cases resolved prior to hospital release. There were no cases of ERCP-related hemorrhage, perforation, pancreatitis, or death. Follow-up time ranged from three to 12 months, during which 23 (95.8% patients showed long-term remission. The presence

  20. Zero-Shot Style Transfer in Text Using Recurrent Neural Networks

    OpenAIRE

    Carlson, Keith; Riddell, Allen; Rockmore, Daniel

    2017-01-01

    Zero-shot translation is the task of translating between a language pair where no aligned data for the pair is provided during training. In this work we employ a model that creates paraphrases which are written in the style of another existing text. Since we provide the model with no paired examples from the source style to the target style during training, we call this task zero-shot style transfer. Herein, we identify a high-quality source of aligned, stylistically distinct text in Bible ve...

  1. MR morphology of triangular fibrocartilage complex: correlation with quantitative MR and biomechanical properties

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Won C.; Chang, Eric Y.; Chung, Christine B. [VA San Diego Healthcare System, Radiology Service, San Diego, CA (United States); University of California-San Diego, Department of Radiology, San Diego, CA (United States); Ruangchaijatuporn, Thumanoon [Mahidol University, Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Rachathewi, Bangkok (Thailand); Biswas, Reni; Du, Jiang; Statum, Sheronda [University of California-San Diego, Department of Radiology, San Diego, CA (United States)

    2016-04-15

    To evaluate pathology of the triangular fibrocartilage complex (TFCC) using high-resolution morphologic magnetic resonance (MR) imaging, and compare with quantitative MR and biomechanical properties. Five cadaveric wrists (22-70 years) were imaged at 3 T using morphologic (proton density weighted spin echo, PD FS, and 3D spoiled gradient echo, 3D SPGR) and quantitative MR sequences to determine T2 and T1rho properties. In eight geographic regions, morphology of TFC disc and laminae were evaluated for pathology and quantitative MR values. Samples were disarticulated and biomechanical indentation testing was performed on the distal surface of the TFC disc. On morphologic PD SE images, TFC disc pathology included degeneration and tears, while that of the laminae included degeneration, degeneration with superimposed tear, mucinous transformation, and globular calcification. Punctate calcifications were highly visible on 3D SPGR images and found only in pathologic regions. Disc pathology occurred more frequently in proximal regions of the disc than distal regions. Quantitative MR values were lowest in normal samples, and generally higher in pathologic regions. Biomechanical testing demonstrated an inverse relationship, with indentation modulus being high in normal regions with low MR values. The laminae studied were mostly pathologic, and additional normal samples are needed to discern quantitative changes. These results show technical feasibility of morphologic MR, quantitative MR, and biomechanical techniques to characterize pathology of the TFCC. Quantitative MRI may be a suitable surrogate marker of soft tissue mechanical properties, and a useful adjunct to conventional morphologic MR techniques. (orig.)

  2. MR morphology of triangular fibrocartilage complex: correlation with quantitative MR and biomechanical properties

    International Nuclear Information System (INIS)

    Bae, Won C.; Chang, Eric Y.; Chung, Christine B.; Ruangchaijatuporn, Thumanoon; Biswas, Reni; Du, Jiang; Statum, Sheronda

    2016-01-01

    To evaluate pathology of the triangular fibrocartilage complex (TFCC) using high-resolution morphologic magnetic resonance (MR) imaging, and compare with quantitative MR and biomechanical properties. Five cadaveric wrists (22-70 years) were imaged at 3 T using morphologic (proton density weighted spin echo, PD FS, and 3D spoiled gradient echo, 3D SPGR) and quantitative MR sequences to determine T2 and T1rho properties. In eight geographic regions, morphology of TFC disc and laminae were evaluated for pathology and quantitative MR values. Samples were disarticulated and biomechanical indentation testing was performed on the distal surface of the TFC disc. On morphologic PD SE images, TFC disc pathology included degeneration and tears, while that of the laminae included degeneration, degeneration with superimposed tear, mucinous transformation, and globular calcification. Punctate calcifications were highly visible on 3D SPGR images and found only in pathologic regions. Disc pathology occurred more frequently in proximal regions of the disc than distal regions. Quantitative MR values were lowest in normal samples, and generally higher in pathologic regions. Biomechanical testing demonstrated an inverse relationship, with indentation modulus being high in normal regions with low MR values. The laminae studied were mostly pathologic, and additional normal samples are needed to discern quantitative changes. These results show technical feasibility of morphologic MR, quantitative MR, and biomechanical techniques to characterize pathology of the TFCC. Quantitative MRI may be a suitable surrogate marker of soft tissue mechanical properties, and a useful adjunct to conventional morphologic MR techniques. (orig.)

  3. MR morphology of triangular fibrocartilage complex: correlation with quantitative MR and biomechanical properties.

    Science.gov (United States)

    Bae, Won C; Ruangchaijatuporn, Thumanoon; Chang, Eric Y; Biswas, Reni; Du, Jiang; Statum, Sheronda; Chung, Christine B

    2016-04-01

    To evaluate pathology of the triangular fibrocartilage complex (TFCC) using high-resolution morphologic magnetic resonance (MR) imaging, and compare with quantitative MR and biomechanical properties. Five cadaveric wrists (22-70 years) were imaged at 3 T using morphologic (proton density weighted spin echo, PD FS, and 3D spoiled gradient echo, 3D SPGR) and quantitative MR sequences to determine T2 and T1rho properties. In eight geographic regions, morphology of TFC disc and laminae were evaluated for pathology and quantitative MR values. Samples were disarticulated and biomechanical indentation testing was performed on the distal surface of the TFC disc. On morphologic PD SE images, TFC disc pathology included degeneration and tears, while that of the laminae included degeneration, degeneration with superimposed tear, mucinous transformation, and globular calcification. Punctate calcifications were highly visible on 3D SPGR images and found only in pathologic regions. Disc pathology occurred more frequently in proximal regions of the disc than distal regions. Quantitative MR values were lowest in normal samples, and generally higher in pathologic regions. Biomechanical testing demonstrated an inverse relationship, with indentation modulus being high in normal regions with low MR values. The laminae studied were mostly pathologic, and additional normal samples are needed to discern quantitative changes. These results show technical feasibility of morphologic MR, quantitative MR, and biomechanical techniques to characterize pathology of the TFCC. Quantitative MRI may be a suitable surrogate marker of soft tissue mechanical properties, and a useful adjunct to conventional morphologic MR techniques.

  4. Different intensities of basketball drills affect jump shot accuracy of expert and junior players

    Directory of Open Access Journals (Sweden)

    Giuseppe Marcolin

    2018-02-01

    Full Text Available Background In basketball a maximum accuracy at every game intensity is required while shooting. The aim of the present study was to investigate the acute effect of three different drill intensity simulation protocols on jump shot accuracy in expert and junior basketball players. Materials & Methods Eleven expert players (age 26 ± 6 yrs, weight 86 ± 11 kg, height 192 ± 8 cm and ten junior players (age 18 ± 1 yrs, weight 75 ± 12 kg, height 184 ± 9 cm completed three series of twenty jump shots at three different levels of exertion. Counter Movement Jump (CMJ height was also measured after each series of jump shots. Exertion’s intensity was induced manipulating the basketball drills. Heart rate was measured for the whole duration of the tests while the rating of perceived exertion (RPE was collected at the end of each series of shots. Results Heart rate and rating of perceived exertion (RPE were statistically different in the three conditions for both expert and junior players. CMJ height remained almost unchanged in both groups. Jump shot accuracy decreased with increasing drills intensity both in experts and junior players. Expert players showed higher accuracy than junior players for all the three levels of exertion (83% vs 64%, p < 0.001; 75% vs 57%, p < 0.05; 76% vs 60%, p < 0.01. Moreover, for the most demanding level of exertion, experts showed a higher accuracy in the last ten shots compared to the first ten shots (82% vs 70%, p < 0.05. Discussion Experts coped better with the different exertion’s intensities, thus maintaining a higher level of performance. The introduction of technical short bouts of high-intensity sport-specific exercises into skill sessions should be proposed to improve jump shot accuracy during matches.

  5. First-time viewers' comprehension of films: bridging shot transitions.

    Science.gov (United States)

    Ildirar, Sermin; Schwan, Stephan

    2015-02-01

    Which perceptual and cognitive prerequisites must be met in order to be able to comprehend a film is still unresolved and a controversial issue. In order to gain some insights into this issue, our field experiment investigates how first-time adult viewers extract and integrate meaningful information across film cuts. Three major types of commonalities between adjacent shots were differentiated, which may help first-time viewers with bridging the shots: pictorial, causal, and conceptual. Twenty first-time, 20 low-experienced and 20 high-experienced viewers from Turkey were shown a set of short film clips containing these three kinds of commonalities. Film clips conformed also to the principles of continuity editing. Analyses of viewers' spontaneous interpretations show that first-time viewers indeed are able to notice basic pictorial (object identity), causal (chains of activity), as well as conceptual (links between gaze direction and object attention) commonalities between shots due to their close relationship with everyday perception and cognition. However, first-time viewers' comprehension of the commonalities is to a large degree fragile, indicating the lack of a basic notion of what constitutes a film. © 2014 The British Psychological Society.

  6. MR-sialography: optimisation and evaluation of an ultra-fast sequence in parallel acquisition technique and different functional conditions of salivary glands; MR-Sialographie: Optimierung und Bewertung ultraschneller Sequenzen mit paralleler Bildgebung und oraler Stimulation

    Energy Technology Data Exchange (ETDEWEB)

    Habermann, C.R.; Cramer, M.C.; Aldefeld, D.; Weiss, F.; Kaul, M.G.; Adam, G. [Radiologisches Zentrum, Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany); Graessner, J. [Siemens Medical Systems, Hamburg (Germany); Reitmeier, F.; Jaehne, M. [Kopf- und Hautzentrum, Klinik und Poliklinik fuer Hals-, Nasen- und Ohrenheilkunde, Universitaetsklinikum Hamburg-Eppendorf (Germany); Petersen, K.U. [Zentrum fuer Psychosoziale Medizin, Klinik und Poliklinik fuer Psychiatrie und Psychotherapie, Universitaetsklinikum Hamburg-Eppendorf (Germany)

    2005-04-01

    Purpose: To optimise a fast sequence for MR-sialography and to compare a parallel and non-parallel acquisition technique. Additionally, the effect of oral stimulation regarding the image quality was evaluated. Material and Methods: All examinations were performed by using a 1.5-T superconducting system. After developing a sufficient sequence for MR-sialography, a single-shot turbo-spin-echo sequence (ss-TSE) with an acquisition time of 2.8 sec was used in transverse and oblique sagittal orientation in 27 healthy volunteers. All images were performed with and without parallel imaging technique. The assessment of the ductal system of the submandibular and parotid gland was performed using a 1 to 5 visual scale for each side separately. Images were evaluated by four independent experienced radiologists. For statistical evaluation, an ANOVA with post-hoc comparisons was used with an overall two-tailed significance level of P=.05. For evaluation of interobserver variability, an intraclass correlation was computed and correlation >.08 was determined to indicate a high correlation. Results: All parts of salivary excretal ducts could be visualised in all volunteers, with an overall rating for all ducts of 2.26 (SD{+-}1.09). Between the four observers a high correlation could be obtained with an intraclass correlation of 0.9475. A significant influence regarding the slice angulations could not be obtained (p=0.74). In all healthy volunteers the visibility of excretory ducts improved significantly after oral application of a Sialogogum (p<0.001; {eta}{sup 2}=0.049). The use of a parallel imaging technique did not lead to an improvement of visualisation, showing a significant loss of image quality compared to an acquistion technique without parallel imaging (p<0.001; {eta}{sup 2}=0.013). Conclusion: The optimised ss-TSE MR-sialography seems to be a fast and sufficient technique for visualisation of excretory ducts of the main salivary glands, with no elaborate post

  7. Shot-Peening Effect on High Cycling Fatigue of Al-Cu Alloy

    Science.gov (United States)

    Fouad, Yasser; Metwally, Mostafa El

    2013-12-01

    The present work was aimed at evaluating the effects of shot-peening on the high cycle fatigue performance of the age-hardening aircraft alloy Al 2024 at different almen intensities. Shot-peening to full coverage (100 pct) was performed using spherically conditioned cut wire (SCCW 14) with an average shot size of 0.36 mm and at almen intensities of 0.1, 0.2, and 0.3 mmA. After applying the various mechanical surface treatments, the changes in the surface and near-surface layer properties such as microhardness, residual stress-depth profiles, and surface roughness were determined. The microhardness, surface roughness, and the residual stresses increased proportionally with the almen intensity. Electropolitically polished conditions were used as reference in the mechanically surface treated specimens. A significant improvement was seen in the fatigue performance of the 0.1 mmA.

  8. Single-Shot Spectrometry for X-Ray Free-Electron Lasers

    International Nuclear Information System (INIS)

    Yabashi, Makina; Ishikawa, Tetsuya; Hastings, Jerome B.; Zolotorev, Max S.; Mimura, Hidekazu; Yumoto, Hirokatsu; Matsuyama, Satoshi; Yamauchi, Kazuto

    2006-01-01

    An experimental scheme to realize single-shot spectrometry for the diagnostics of x-ray free-electron lasers (XFELs) is presented. The combination of an ultraprecisely figured mirror and a perfect crystal form a simple, high-precision spectrometer that can cover an energy range from a few eV to a hundred eV with high resolution. The application of the spectrometer to determine XFEL pulse widths was investigated theoretically and experimentally. It has been shown that the present system can determine pulse widths from sub-fs to ps in a single shot even for spontaneous radiation. The system can be easily extended to even shorter pulses

  9. MR imaging of normal bone marrow; Obraz MR prawidlowego szpiku kostnego

    Energy Technology Data Exchange (ETDEWEB)

    Stajgis, M.; Paprzycki, W. [Osrodek Diagnostyki Obrazowej IR, Akademia Medyczna, Poznan (Poland)

    1994-12-31

    Principles of MR bone marrow imaging on the basis of retrospective analysis of MR examinations of bone marrow in different anatomic sites in 200 patients have been discussed. Significance of different physiologic factors and processes such as age, steatosis, osteoporosis, conversion and reconversion, which influence on MR bone marrow images, have been emphasized. T1-weighted images obtained with spin-echo sequences give the most of information about bone marrow structure in MR. Thorough knowledge of bone marrow physiology and clinical status of the patient is indispensable in correct interpretation of hypointensive lesions on T1-weighted images. When presence of disseminated bone marrow disease is suspected, authors propose routine imaging of lumbar vertebral column, pelvis and proximal parts of femoral bones. (author) 7 refs, 7 figs

  10. Effect of Shot Peening on Tribological Behaviors of Molybdenum-Thermal Spray Coating using HVOF Method

    Directory of Open Access Journals (Sweden)

    H. Mohassel

    2017-03-01

    Full Text Available We have investigated the influence of post-shot peening on Mo-coating as compared to substrate steel 16MnCr5 (according to ZFN-413 A. Shot peening of carburized steel discs with and without Mo-coating was performed by using Shot size S230, Almen intensity 0.42 mm ’A’ and exposure time 96 sec. Tribological properties were analyzed, using pin-on-disc tribometer apparatus, under dry sliding conditions at different specific applied loads, sliding velocities and distance. Typical standardized methods were used for studying of surface integrity parameters (micro-hardness, topography and surface roughness. Surface morphology of the Mo-coating specimens with and without Shot Peening before and after wear was evaluated by Scanning Electron Microscopy. The results showed that shot peening after Mo-coating has considerable effect on improving wear resistance and because of having low friction coefficient has showed better wear behavior and tribologi cal properties over that of the un-peened Mo-coating.

  11. MR imaging of rhabdomyolysis

    International Nuclear Information System (INIS)

    Zagoria, R.J.; Karstaedt, N.; Koubek, T.D.

    1986-01-01

    The use of magnetic resonance (MR) imaging in two cases of rhabdomyolysis, one resulting from prolonged muscle compression and one from electrical burns, is described. The involved muscles were clearly demonstrated with MR. Recognition and assessment of the extent of rhabdomyolysis are important since life-threatening sequelae including severe metabolic disorders are possible. In one case, spin-echo and inversion-recovery MR imaging provided greater detail of muscle abnormalities than did 99mTc-pyrophosphate radionuclide scanning. Both cases illustrate the usefulness of MR in evaluation of skeletal muscle disorders

  12. Shot noise and electronic properties in the inversion-symmetric Weyl semimetal resonant structure

    Science.gov (United States)

    Yang, Yanling; Bai, Chunxu; Xu, Xiaoguang; Jiang, Yong

    2018-02-01

    Using the transfer matrix method, the authors combine the analytical formula with numerical calculation to explore the shot noise and conductance of massless Weyl fermions in the Weyl semimetal resonant junction. By varying the barrier strength, the structure of the junction, the Fermi energy, and the crystallographic angle, the shot noise and conductance can be tuned efficiently. For a quasiperiodic superlattice, in complete contrast to the conventional junction case, the effect of the disorder strength on the shot noise and conductance depends on the competition of classical tunneling and Klein tunneling. Moreover, the delta barrier structure is also vital in determining the shot noise and conductance. In particular, a universal Fano factor has been found in a single delta potential case, whereas the resonant structure of the Fano factor perfectly matches with the number of barriers in a delta potential superlattice. These results are crucial for engineering nanoelectronic devices based on this topological semimetal material.

  13. Preparation of Ultracold Atom Clouds at the Shot Noise Level

    DEFF Research Database (Denmark)

    Gajdacz, M.; Hilliard, A. J.; Kristensen, Mick

    2016-01-01

    We prepare number stabilized ultracold atom clouds through the real-time analysis of nondestructive images and the application of feedback. In our experiments, the atom number N∼10^6 is determined by high precision Faraday imaging with uncertainty ΔN below the shot noise level, i.e., ΔN... on this measurement, feedback is applied to reduce the atom number to a user-defined target, whereupon a second imaging series probes the number stabilized cloud. By this method, we show that the atom number in ultracold clouds can be prepared below the shot noise level....

  14. MR imaging and MR angiography in popliteal artery entrapment syndrome

    International Nuclear Information System (INIS)

    Atilla, S.; Akpek, S.; Yuecel, C.; Tali, E.T.; Isik, S.; Ilgit, E.T.

    1998-01-01

    Popliteal artery entrapment (PAE) syndrome is an uncommon congenital anomaly seen in young adults causing ischemic symptoms in the lower extremities. It is the result of various types of anomalous relationships between the popliteal artery and the neighboring muscular structures. The purpose of this study was to define the role of MR imaging combined with MR angiography in the diagnosis of PAE cases. Four cases with segmental occlusion and medial displacement of popliteal artery in digital subtraction angiography (DSA) examinations were diagnosed as PAE syndrome by MR imaging and MR angiography. The DSA and MRA images are compared. All of the cases showed various degrees of abnormal intercondylar insertion of the medial head of the gastrocnemius muscle. The MR images showed detailed anatomy of the region revealing the cause of the arterial entrapment. Subclassification of the cases were done and fat tissue filling the normal localization of the muscle was evaluated. The DSA and MRA images demonstrated the length and localization of the occluded segment and collateral vascular developments equally. It is concluded that angiographic evaluation alone in PAE syndrome might result in overlooking the underlying cause of the arterial occlusion, which in turn leads to unsuccessful therapy procedures such as balloon angioplasty. Magnetic resonance imaging combined with MR angiography demonstrates both the vascular anatomy and the variations in the muscular structures in the popliteal fossa successfully, and this combination seems to be the most effective way of evaluating young adults with ischemic symptoms suggesting PAE syndrome. (orig.)

  15. Accuracy of 3-Tesla MR and MR arthrography in diagnosis of meniscal retear in the post-operative knee

    Energy Technology Data Exchange (ETDEWEB)

    Magee, Thomas [NSI, Merritt Island, FL (United States); University of Central Florida School of Medicine, Orlando, FL (United States)

    2014-08-15

    This study assesses the accuracy of 3-Tesla (3-T) conventional MR imaging, 3-T MR arthrography, and the combined use of conventional MR and MR arthrography in the diagnosis of meniscal retears as compared with arthroscopy. The study also assess whether there are false-negative cases in which injected contrast does not extend into the meniscus despite a meniscal retear being seen on arthroscopy. One hundred consecutive knee MR arthrograms performed on patients with previous knee surgery were reviewed retrospectively. 3-T conventional MR imaging, 3-T MR arthrography, and the combined use of conventional MR and MR arthrography were assessed for meniscal retears as compared with arthroscopy. The criterion used to diagnose a meniscal retear on MR arthrogram was injected contrast tracking into the meniscus. All patients underwent second-look arthroscopy. Seventy-four patients had conventional MR findings consistent with a meniscal retear. In 83 of the 100 patients, intraarticular contrast helped in demonstrating a retear. In ten patients, there were MR findings consistent with a meniscal retear despite intra-articular contrast not tracking into the meniscus. Ninety-four of the 100 patients had meniscal retears on second-look arthroscopy. Three-Tesla conventional MR examination was 78 % sensitive and 75 % specific, MR arthrogram examination was 88 % sensitive and 100 % specific, and the combined use of MR and MR arthrogram imaging was 98 % sensitive and 75 % specific in the diagnosis of a meniscal retear. The combined use of 3-T MR and MR arthrography allows for high sensitivity and specificity in meniscal retear detection. In some patients, intraarticular contrast will not track into a meniscal retear. When MR findings are consistent with a meniscal retear but contrast does not extend into the meniscus, a meniscal retear is likely. (orig.)

  16. Von Mr Classic zu Mr Nerd: Wie Forschende soziale Medien nutzen

    Directory of Open Access Journals (Sweden)

    Doreen Siegfried

    2014-12-01

    Full Text Available Unter Wissenschaftlerinnen und Wissenschaftlern lassen sich vier Typen differenzieren, die ein signifikant unterschiedliches Verhalten in ihrer Nutzung und ihrer Einstellung gegenüber Social-Web-Anwendungen zeigen: Ms Maker, Mr Tech, Mr Classic und Mr Nerd. Grundlage für die Identifizierung dieser Social-Media-Typen ist die Auswertung von 778 Online-Fragebögen, die von Anfang September bis Mitte Oktober 2013 erhoben wurden. Erfragt wurde die Nutzung von Social-Media-Instrumenten für die tägliche Arbeit in Forschung, Lehre, Administration und Wissenschaftskommunikation. Neben Intensität und Kontext der Nutzung von Web-2.0-Diensten wurden auch die Gründe für Nutzung bzw. Nicht-Nutzung einzelner Kanäle sowie generelle Einstellungen gegenüber Social-Media-Werkzeugen erfragt. Among scientists, four types of personality can be identified whose usage and attitude towards social web applications show significant variations: Ms Maker, Mr Tech, Mr Classic and Mr Nerd. This typification is based on 778 online questionnaires received between September and October 2013. The survey sampled the usage of social media tools for daily routines in research, teaching, administrative work and scholarly communication. The survey asked questions about the intensity and the context in which Web 2.0 services are used, about the reasons for (not using certain channels, and about general attitudes towards social media tools.

  17. Endoscopic retrograde cholangiopancreatography with rendezvous cannulation reduces pancreatic injury.

    Science.gov (United States)

    Swahn, Fredrik; Regnér, Sara; Enochsson, Lars; Lundell, Lars; Permert, Johan; Nilsson, Magnus; Thorlacius, Henrik; Arnelo, Urban

    2013-09-28

    To examine whether rendezvous endoscopic retrograde cholangiopancreatography (ERCP) is associated with less pancreatic damage, measured as leakage of proenzymes, than conventional ERCP. Patients (n = 122) with symptomatic gallstone disease, intact papilla and no ongoing inflammation, were prospectively enrolled in this case-control designed study. Eighty-one patients were subjected to laparoscopic cholecystectomy and if intraoperative cholangiography suggested common bile duct stones (CBDS), rendezvous ERCP was performed intraoperatively (n = 40). Patients with a negative cholangiogram constituted the control group (n = 41). Another 41 patients with CBDS, not subjected to surgery, underwent conventional ERCP. Pancreatic proenzymes, procarboxypeptidase B and trypsinogen-2 levels in plasma, were analysed at 0, 4, 8 and 24 h. The proenzymes were determined in-house with a double-antibody enzyme linked immunosorbent assay. Pancreatic amylase was measured by an enzymatic colourimetric modular analyser with the manufacturer's reagents. All samples were blinded at analysis. Post ERCP pancreatitis (PEP) occurred in 3/41 (7%) of the patients cannulated with conventional ERCP and none in the rendezvous group. Increased serum levels indicating pancreatic leakage were significantly higher in the conventional ERCP group compared with the rendezvous ERCP group regarding pancreatic amylase levels in the 4- and 8-h samples (P = 0.0015; P = 0.03), procarboxypeptidase B in the 4- and 8-h samples (P rendezvous cannulation technique compared with patients that underwent cholecystectomy alone (control group). Post procedural concentrations of pancreatic amylase and procarboxypeptidase B were significantly correlated with pancreatic duct cannulation and opacification. Rendezvous ERCP reduces pancreatic enzyme leakage compared with conventional ERCP cannulation technique. Thus, laparo-endoscopic technique can be recommended with the ambition to minimise the risk for post ERCP

  18. Polio and the Vaccine (Shot) to Prevent It

    Science.gov (United States)

    ... and Teen Vaccine Resources Related Links Vaccines & Immunizations Polio and the Vaccine (Shot) to Prevent It Language: ... recommend all children get the vaccine. What is polio? Polio (or poliomyelitis) is a disease caused by ...

  19. Clarifying beliefs underlying hunter intentions to support a ban on lead shot

    Science.gov (United States)

    Schroeder, Susan A.; Fulton, David C.; Doncarlos, Kathy

    2016-01-01

    Shot from hunting adds toxic lead to environments worldwide. Existing lead shot regulations have been instituted with little understanding of hunter beliefs and attitudes. This study applied the Theory of Reasoned Action, using a multilevel, multivariate approach, to clarify how positive and negative beliefs relate to attitudes about a ban on lead shot. Structure coefficients and commonality analysis were employed to further examine relationships between beliefs and attitudes. Results suggest that while both positive and negative outcomes influence attitudes, positive outcomes were more influential for supporters and negative beliefs for opposers. Management may need to focus on the results from hunters who indicated that they would be unlikely to support a ban, as these hunters include those who may actively oppose additional efforts to regulate lead.

  20. Space based lidar shot pattern targeting strategies for small targets such as streams

    Science.gov (United States)

    Spiers, Gary D.

    2001-01-01

    An analysis of the effectiveness of four different types of lidar shot distribution is conducted to determine which is best for concentrating shots in a given location. A simple preemptive targeting strategy is found to work as adequately as a more involved dynamic strategy for most target sizes considered.