WorldWideScience

Sample records for short-wavelength automated perimetry

  1. Short wavelength automated perimetry can detect visual field changes in diabetic patients without retinopathy

    Directory of Open Access Journals (Sweden)

    Othman Ali Zico

    2014-01-01

    Full Text Available Purpose: The purpose of the following study is to compare short wave automated perimetry (SWAP versus standard automated perimetry (SAP for early detection of diabetic retinopathy (DR. Materials and Methods: A total of 40 diabetic patients, divided into group I without DR (20 patients = 40 eyes and group II with mild non-proliferative DR (20 patients = 40 eyes were included. They were tested with central 24-2 threshold test with both shortwave and SAP to compare sensitivity values and local visual field indices in both of them. A total of 20 healthy age and gender matched subjects were assessed as a control group. Results: Control group showed no differences between SWAP and SAP regarding mean deviation (MD, corrected pattern standard deviation (CPSD or short fluctuations (SF. In group I, MD showed significant more deflection in SWAP (−4.44 ± 2.02 dB compared to SAP (−0.96 ± 1.81 dB (P = 0.000002. However, CPSD and SF were not different between SWAP and SAP. In group II, MD and SF showed significantly different values in SWAP (−5.75 ± 3.11 dB and 2.0 ± 0.95 compared to SAP (−3.91 ± 2.87 dB and 2.86 ± 1.23 (P = 0.01 and 0.006 respectively. There are no differences regarding CPSD between SWAP and SAP. The SWAP technique was significantly more sensitive than SAP in patients without retinopathy (p, but no difference exists between the two techniques in patients with non-proliferative DR. Conclusion: The SWAP technique has a higher yield and efficacy to pick up abnormal findings in diabetic patients without overt retinopathy rather than patients with clinical retinopathy.

  2. Comparison of Size Modulation Standard Automated Perimetry and Conventional Standard Automated Perimetry with a 10-2 Test Program in Glaucoma Patients.

    Science.gov (United States)

    Hirasawa, Kazunori; Takahashi, Natsumi; Satou, Tsukasa; Kasahara, Masayuki; Matsumura, Kazuhiro; Shoji, Nobuyuki

    2017-08-01

    This prospective observational study compared the performance of size modulation standard automated perimetry with the Octopus 600 10-2 test program, with stimulus size modulation during testing, based on stimulus intensity and conventional standard automated perimetry, with that of the Humphrey 10-2 test program in glaucoma patients. Eighty-seven eyes of 87 glaucoma patients underwent size modulation standard automated perimetry with Dynamic strategy and conventional standard automated perimetry using the SITA standard strategy. The main outcome measures were global indices, point-wise threshold, visual defect size and depth, reliability indices, and test duration; these were compared between size modulation standard automated perimetry and conventional standard automated perimetry. Global indices and point-wise threshold values between size modulation standard automated perimetry and conventional standard automated perimetry were moderately to strongly correlated (p 33.40, p modulation standard automated perimetry than with conventional standard automated perimetry, but the visual-field defect size was smaller (p modulation-standard automated perimetry than on conventional standard automated perimetry. The reliability indices, particularly the false-negative response, of size modulation standard automated perimetry were worse than those of conventional standard automated perimetry (p modulation standard automated perimetry than with conventional standard automated perimetry (p = 0.02). Global indices and the point-wise threshold value of the two testing modalities correlated well. However, the potential of a large stimulus presented at an area with a decreased sensitivity with size modulation standard automated perimetry could underestimate the actual threshold in the 10-2 test protocol, as compared with conventional standard automated perimetry.

  3. Improved automated perimetry performance in elderly subjects after listening to Mozart.

    Science.gov (United States)

    Marques, Junia Cabral; Vanessa, Adriana Chaves Oliveira; Fiorelli, Macedo Batista; Kasahara, Niro

    2009-01-01

    To evaluate the performance of automated perimetry of elderly subjects naïve to AP after listening to a Mozart sonata. Automated perimetry (AP) is a psychophysical test used to assess visual fields in patients with neurological disorders and glaucoma. In a previous study, Fiorelli et al. showed that young subjects who listened to a Mozart sonata prior to undergoing AP performed better in terms of reliability than those who did not listen to the sonata. Fifty-two AP-naïve, normal subjects underwent Automated perimetry (SITA 24-2). The study group (25 subjects) underwent AP after listening to Mozart's Sonata for Two Pianos in D Major, and the control group (27 subjects) underwent Automated perimetry without prior exposure to the music. The study group had significantly lower false negative rates and a lower visual field reliability score than the controls (P=0.04 and P=0.04, respectively). The test time was shorter for the study group (P=0.03). This study shows that elderly subjects, when exposed to the Mozart sonata immediately before AP testing, have lower false negative rates and lower visual field reliability scores when compared with an age- and gender-matched control group. Our results differ from those of Fiorelli et al. who found lower false positive rates and less fixation loss in addition to lower false negative rates. Listening to a Mozart sonata seems to improve automated perimetry reliability in elderly subjects.

  4. Improved automated perimetry performance in elderly subjects after listening to Mozart

    Directory of Open Access Journals (Sweden)

    Junia Cabral Marques

    2009-01-01

    Full Text Available PURPOSE: To evaluate the performance of automated perimetry of elderly subjects naïve to AP after listening to a Mozart sonata. INTRODUCTION: Automated perimetry (AP is a psychophysical test used to assess visual fields in patients with neurological disorders and glaucoma. In a previous study, Fiorelli et al. showed that young subjects who listened to a Mozart sonata prior to undergoing AP performed better in terms of reliability than those who did not listen to the sonata. METHODS: Fifty-two AP-naïve, normal subjects underwent Automated perimetry (SITA 24-2. The study group (25 subjects underwent AP after listening to Mozart's Sonata for Two Pianos in D Major, and the control group (27 subjects underwent Automated perimetry without prior exposure to the music. RESULTS: The study group had significantly lower false negative rates and a lower visual field reliability score than the controls (P=0.04 and P=0.04, respectively. The test time was shorter for the study group (P=0.03. DISCUSSION: This study shows that elderly subjects, when exposed to the Mozart sonata immediately before AP testing, have lower false negative rates and lower visual field reliability scores when compared with an age- and gender-matched control group. Our results differ from those of Fiorelli et al. who found lower false positive rates and less fixation loss in addition to lower false negative rates. CONCLUSION: Listening to a Mozart sonata seems to improve automated perimetry reliability in elderly subjects.

  5. Relationship between short-wavelength automatic perimetry and Heidelberg retina tomograph parameters in eyes with ocular hypertension

    Directory of Open Access Journals (Sweden)

    Christos Pitsas

    2015-10-01

    Full Text Available AIM:To compare and correlate optic nerve head parameters obtained byHeidelberg retina tomograph (HRT with short-wavelength automatic perimetry (SWAP indices in eyes with ocular hypertension (OHT.METHODS: One hundred and forty-six patients with OHT included in the present study. All subjects had reliable SWAP and HRT measurements performed within a 2wk period. The eyes were classified as normal/abnormal according to visual field criteria and Moorfields regression analysis (MRA. Correlations between visual field indices and HRT parameters were analyzed using Pearson correlation coefficient (r.RESULTS:Twenty-nine eyes (19.9% had SWAP defects. Twenty-nine eyes (19.9% were classified as abnormal according to global MRA. Six eyes (4.1% had abnormal global MRA and SWAP defects. The k statistic is 0.116 (P=0.12 indicating a very poor agreement between the methods. No statistical significant correlation between HRT and SWAP parameters was detected.CONCLUSION:SWAP defects may coexist with abnormalities of optic disc detected by HRT in eyes with OHT. In most eyes, however, the two methods detect different glaucoma properties.

  6. The relationship between standard automated perimetry and GDx VCC measurements

    NARCIS (Netherlands)

    N.J. Reus; H.G. Lemij (Hans)

    2004-01-01

    textabstractPURPOSE: To investigate the relationship between retinal light sensitivity measured with standard automated perimetry (SAP) and retardation of the peripapillary retinal nerve fiber layer (RNFL) measured with the GDx VCC (Laser Diagnostic Technologies, Inc., San Diego,

  7. Influence of blue light spectrum filter on short-wavelength and standard automated perimetries Influência de filtro para o espectro azul da luz na perimetria computadorizada branco-branco e azul-amarelo

    Directory of Open Access Journals (Sweden)

    Leonardo Cunha Castro

    2006-10-01

    Full Text Available PURPOSE: To evaluate the influence of a blue light spectrum filter (BLSF, similar in light spectrum transmittance to the intraocular lens Acrysof NaturalTM, on standard automated perimetry (SAP and short-wavelength automated perimetry (SWAP. METHODS: Twenty young individuals (OBJETIVO: Avaliar a influência de um filtro para o espectro azul da luz, semelhante à lente intra-ocular Acrysof Natural®, nos exames de perimetria automatizada padrão (branco-no-branco e de comprimento de onda curto (azul-no-amarelo. MÉTODOS: Vinte pacientes jovens sem alterações oculares (20 olhos realizaram seqüência de 4 exames de campo visual: perimetria automatizada padrão e azul-no-amarelo com e sem o filtro para o espectro azul da luz. Os índices de limiar foveal (FT, desvio médio (MD e desvio-padrão (PSD obtidos em todos os exames e a diferença causada pela excentricidade nos exames de perimetria automatizada azul-no-amarelo foram analisados. Variabilidade interindivíduos (desvio-padrão dos pontos testados foi calculada. RESULTADOS: Observou-se redução estatisticamente significante no desvio médio (p<0.001 e no limiar foveal (p<0.001 medidos pela perimetria automatizada azul-no-amarelo com o uso do filtro para o espectro azul da luz comparado quando realizado sem o filtro. Nenhum outro índice avaliado apresentou diferença estatisticamente significante nos exames de perimetria automatizada padrão ou azul-no-amarelo. Foi notado aumento da variabilidade interindivíduos com a excentricidade nos exames de perimetria automatizada azul-no-amarelo com e sem o uso do filtro para o espectro azul da luz, assim como a diferença de sensibilidade entre os hemisférios inferior e superior (hemisfério inferior menos superior, mas não houve diferença estatisticamente significante quando comparados os exames com e sem o uso do filtro. Quando foram comparados os 4 pontos mais inferiores e os 4 pontos mais superiores, a diferença inferior-superior aumentou

  8. Comparison of Threshold Saccadic Vector Optokinetic Perimetry (SVOP) and Standard Automated Perimetry (SAP) in Glaucoma. Part II: Patterns of Visual Field Loss and Acceptability.

    Science.gov (United States)

    McTrusty, Alice D; Cameron, Lorraine A; Perperidis, Antonios; Brash, Harry M; Tatham, Andrew J; Agarwal, Pankaj K; Murray, Ian C; Fleck, Brian W; Minns, Robert A

    2017-09-01

    We compared patterns of visual field loss detected by standard automated perimetry (SAP) to saccadic vector optokinetic perimetry (SVOP) and examined patient perceptions of each test. A cross-sectional study was done of 58 healthy subjects and 103 with glaucoma who were tested using SAP and two versions of SVOP (v1 and v2). Visual fields from both devices were categorized by masked graders as: 0, normal; 1, paracentral defect; 2, nasal step; 3, arcuate defect; 4, altitudinal; 5, biarcuate; and 6, end-stage field loss. SVOP and SAP classifications were cross-tabulated. Subjects completed a questionnaire on their opinions of each test. We analyzed 142 (v1) and 111 (v2) SVOP and SAP test pairs. SVOP v2 had a sensitivity of 97.7% and specificity of 77.9% for identifying normal versus abnormal visual fields. SAP and SVOP v2 classifications showed complete agreement in 54% of glaucoma patients, with a further 23% disagreeing by one category. On repeat testing, 86% of SVOP v2 classifications agreed with the previous test, compared to 91% of SAP classifications; 71% of subjects preferred SVOP compared to 20% who preferred SAP. Eye-tracking perimetry can be used to obtain threshold visual field sensitivity values in patients with glaucoma and produce maps of visual field defects, with patterns exhibiting close agreement to SAP. Patients preferred eye-tracking perimetry compared to SAP. This first report of threshold eye tracking perimetry shows good agreement with conventional automated perimetry and provides a benchmark for future iterations.

  9. Pupillometer-based objective chromatic perimetry in normal eyes and patients with retinal photoreceptor dystrophies.

    Science.gov (United States)

    Skaat, Alon; Sher, Ifat; Kolker, Andrew; Elyasiv, Sivan; Rosenfeld, Elkana; Mhajna, Mohamad; Melamed, Shlomo; Belkin, Michael; Rotenstreich, Ygal

    2013-04-17

    To evaluate a novel objective perimetry using multifocal chromatic pupil light reflex in normal participants and patients with photoreceptor dysfunction, and to relate this new technique with subjective dark-adapted chromatic Goldmann perimetry. Thirty-two eyes of 17 retinitis pigmentosa (RP) or cone-rod dystrophy patients and 20 eyes of 12 healthy individuals were tested. A computerized infrared video pupillometer was used to record changes in pupil diameter in response to short- and long-wavelength stimuli (peak 485 and 640 nm, respectively; light intensity 40 cd/m(2)) at 13 different points of the 30° visual field (VF), under background illumination of 2.7 cd/m(2). The pupillary response (PR) of patients was compared with PR obtained from normal control participants. In 11 patients, the pupillary responses were also compared with their findings on dark-adapted chromatic Goldmann perimetry. Significantly reduced pupillary responses were obtained in RP patients in response to the short-wavelength stimulus in nearly all perimetric locations (P chromatic Goldmann perimetry. In all patients that were tested by the chromatic Goldmann, minimal PR was recorded in areas that were nondetected in the chromatic Goldmann perimetry. This study demonstrates the potential feasibility of using pupillometer-based chromatic perimetry for objectively assessing VF defects and retinal function in patients with retinal dystrophies. (ClinicalTrials.gov number, NCT01021982.).

  10. Improved automated perimetry performance following exposure to Mozart.

    Science.gov (United States)

    Fiorelli, V Macedo Batista; Kasahara, N; Cohen, R; França, A Santucci; Della Paolera, M; Mandia, C; de Almeida, G Vicente

    2006-05-01

    To evaluate the performance on automated perimetry (AP) after listening to a Mozart sonata in normal subjects naive to AP. 60 naive normal subjects underwent AP (SITA 24-2). The study group (30 subjects) underwent AP after listening to Mozart's Sonata for Two Pianos in D Major and the control group (30 subjects) underwent AP without previous exposure to the music. The study group had significantly less fixation loss, false positive, and false negative rates compared to controls (p Mozart seems to improve AP performance in normal naive subjects.

  11. Field of dreamers and dreamed-up fields: functional and fake perimetry.

    Science.gov (United States)

    Thompson, J C; Kosmorsky, G S; Ellis, B D

    1996-01-01

    Hysterical and malingering patients can manifest visual field defects on perimetry (visual field testing), including defects suggestive of true visual pathway pathology. It has been shown that control subjects can easily imitate some pathologic defects with automated, computed perimetry. The authors sought to determine whether subjects could imitate the same pathologic defect with manual and automated perimetry. Six subjects posed as patients with neurologic problems. They had manual perimetry with both an experienced and inexperienced technician followed by automated perimetry. They were later interviewed about the methods of the technicians and the difficulty of the exercise. Four of six subjects easily imitated the assigned defects with both technicians on manual perimetry and with automated perimetry. These included quadrantic, altitudinal, hemianopic, and enlarged blind-spot defects. Two subjects who were assigned cecocentral and paracentral scotomas instead produced enlarged blind spots by manual perimetry and defects suggestive of chiasmal pathology by automated perimetry. Paradoxically, some subjects found that experienced technicians were easier to fool than inexperienced technicians because of the systematic way in which experienced technicians defined defects. With minimal coaching, some subjects can imitate visual fields with enlarged blind spots, quadrantic, hemianopic, and altitudinal defects with ease and reproducibility by both automated and manual perimetry. Cecocentral and paracentral scotomas are harder to imitate but may be mistaken as representing chiasmal pathology. Paradoxically, experienced technicians may not be better at detecting hysterical or malingering individuals.

  12. [Sensitivity and specificity of flicker perimetry with Pulsar. Comparison with achromatic (white-on-white) perimetry in glaucoma patients].

    Science.gov (United States)

    Göbel, K; Erb, C

    2013-02-01

    The early detection of functional glaucoma damage plays an increasingly more central role in the diagnosis and treatment of glaucoma disease. Using selective perimetry detection of early glaucomatous defects is more likely and one of these methods is flicker perimetry with Pulsar. Flicker perimetry is used to analyze the temporal visual function in combination with spatial resolution and contrast sensitivity as opposed to standard automated perimetry which measures the differential light sensitivity with a non-specific stimulus. This study showed a higher sensitivity and specificity of Pulsar perimetry in comparison to achromatic perimetry in glaucoma patients.

  13. Factors That Influence Standard Automated Perimetry Test Results in Glaucoma : Test Reliability, Technician Experience, Time of Day, and Season

    NARCIS (Netherlands)

    Montolio, Francisco G. Junoy; Wesselink, Christiaan; Gordijn, Marijke; Jansonius, Nomdo M.

    2012-01-01

    PURPOSE. To determine the influence of several factors on standard automated perimetry test results in glaucoma. METHODS. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician experience,

  14. Factors that influence standard automated perimetry test results in glaucoma: Test reliability, technician experience, time of day, and season

    NARCIS (Netherlands)

    F.G.J. Montolio (Francisco G. Junoy); C. Wesselink (Christiaan); M.C.M. Gordijn (Marijke); N.M. Jansonius (Nomdo)

    2012-01-01

    textabstractPURPOSE. To determine the influence of several factors on standard automated perimetry test results in glaucoma. METHODS. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician

  15. Glaucoma progression detection with frequency doubling technology (FDT) compared to standard automated perimetry (SAP) in the Groningen Longitudinal Glaucoma Study.

    Science.gov (United States)

    Wesselink, Christiaan; Jansonius, Nomdo M

    2017-09-01

    To determine the usefulness of frequency doubling perimetry (FDT) for progression detection in glaucoma, compared to standard automated perimetry (SAP). Data were used from 150 eyes of 150 glaucoma patients from the Groningen Longitudinal Glaucoma Study. After baseline, SAP was performed approximately yearly; FDT every other year. First and last visit had to contain both tests. Using linear regression, progression velocities were calculated for SAP (Humphrey Field Analyzer) mean deviation (MD) and FDT MD and the number of test locations with a total deviation probability below p glaucoma progression in patients who cannot perform SAP reliably. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  16. Chromatic-achromatic perimetry in four clinic cases: Glaucoma and diabetes.

    Science.gov (United States)

    Cabezos, Inmaculada; Luque, Maria Jos; de Fez, Dolores; Moncho, Vicenta; Camps, Vicente

    2015-02-01

    Some diseases that affect the visual system may show loss of chromatic-achromatic sensitivity before obvious physical signs appear in the usual examination of the eye's posterior segment. A perimetric study has been conducted with four typical patients with glaucoma and diabetes, at different stages of the disease. In addition to the standard white-on-white (standard automated perimetry [SAP]), a test battery has been used to study patient's contrast sensitivity, using stimuli with different chromatic, spatial, and temporal content (multichannel perimetry). The choice of stimuli tries to maximize the response of different visual mechanisms: Achromatic (parvocellular and magnocellular origin); chromatic red-green (parvocellular origin); and chromatic blue-yellow (koniocellular origin). The results seem to indicate losses in the achromatic-parvocellular perimetry and both chromatic perimetry tests, undetected by conventional SAP. Our results illustrate that our patients without visible retinal alterations show signs of suspicion in multichannel perimetry.

  17. Learning effect and test-retest variability of pulsar perimetry.

    Science.gov (United States)

    Salvetat, Maria Letizia; Zeppieri, Marco; Parisi, Lucia; Johnson, Chris A; Sampaolesi, Roberto; Brusini, Paolo

    2013-03-01

    To assess Pulsar Perimetry learning effect and test-retest variability (TRV) in normal (NORM), ocular hypertension (OHT), glaucomatous optic neuropathy (GON), and primary open-angle glaucoma (POAG) eyes. This multicenter prospective study included 43 NORM, 38 OHT, 33 GON, and 36 POAG patients. All patients underwent standard automated perimetry and Pulsar Contrast Perimetry using white stimuli modulated in phase and counterphase at 30 Hz (CP-T30W test). The learning effect and TRV for Pulsar Perimetry were assessed for 3 consecutive visual fields (VFs). The learning effect were evaluated by comparing results from the first session with the other 2. TRV was assessed by calculating the mean of the differences (in absolute value) between retests for each combination of single tests. TRV was calculated for Mean Sensitivity, Mean Defect, and single Mean Sensitivity for each 66 test locations. Influence of age, VF eccentricity, and loss severity on TRV were assessed using linear regression analysis and analysis of variance. The learning effect was not significant in any group (analysis of variance, P>0.05). TRV for Mean Sensitivity and Mean Defect was significantly lower in NORM and OHT (0.6 ± 0.5 spatial resolution contrast units) than in GON and POAG (0.9 ± 0.5 and 1.0 ± 0.8 spatial resolution contrast units, respectively) (Kruskal-Wallis test, P=0.04); however, the differences in NORM among age groups was not significant (Kruskal-Wallis test, P>0.05). Slight significant differences were found for the single Mean Sensitivity TRV among single locations (Duncan test, PPulsar Perimetry CP-T30W test did not show significant learning effect in patients with standard automated perimetry experience. TRV for global indices was generally low, and was not related to patient age; it was only slightly affected by VF defect eccentricity, and significantly influenced by VF loss severity.

  18. Chromatic-achromatic perimetry in four clinic cases: Glaucoma and diabetes

    Directory of Open Access Journals (Sweden)

    Inmaculada Cabezos

    2015-01-01

    Full Text Available Background: Some diseases that affect the visual system may show loss of chromatic-achromatic sensitivity before obvious physical signs appear in the usual examination of the eye′s posterior segment. A perimetric study has been conducted with four typical patients with glaucoma and diabetes, at different stages of the disease. Materials and Methods: In addition to the standard white-on-white (standard automated perimetry [SAP], a test battery has been used to study patient′s contrast sensitivity, using stimuli with different chromatic, spatial, and temporal content (multichannel perimetry. The choice of stimuli tries to maximize the response of different visual mechanisms: Achromatic (parvocellular and magnocellular origin; chromatic red-green (parvocellular origin; and chromatic blue-yellow (koniocellular origin. Results: The results seem to indicate losses in the achromatic-parvocellular perimetry and both chromatic perimetry tests, undetected by conventional SAP. Conclusions: Our results illustrate that our patients without visible retinal alterations show signs of suspicion in multichannel perimetry.

  19. Comparison of Matrix Frequency-Doubling Technology (FDT) Perimetry with the SWEDISH Interactive Thresholding Algorithm (SITA) Standard Automated Perimetry (SAP) in Mild Glaucoma.

    Science.gov (United States)

    Doozandeh, Azadeh; Irandoost, Farnoosh; Mirzajani, Ali; Yazdani, Shahin; Pakravan, Mohammad; Esfandiari, Hamed

    2017-01-01

    This study aimed to compare second-generation frequency-doubling technology (FDT) perimetry with standard automated perimetry (SAP) in mild glaucoma. Forty-seven eyes of 47 participants who had mild visual field defect by SAP were included in this study. All participants were examined using SITA 24-2 (SITA-SAP) and matrix 24-2 (Matrix-FDT). The correlations of global indices and the number of defects on pattern deviation (PD) plots were determined. Agreement between two sets regarding the stage of visual field damage was assessed. Pearson's correlation, intra-cluster comparison, paired t-test, and 95% limit of agreement were calculated. Although there was no significant difference between global indices, the agreement between the two devices regarding the global indices was weak (the limit of agreement for mean deviation was -6.08 to 6.08 and that for pattern standard deviation was -4.42 to 3.42). The agreement between SITA-SAP and Matrix-FDT regarding the Glaucoma Hemifield Test (GHT) and the number of defective points in each quadrant and staging of the visual field damage was also weak. Because the correlation between SITA-SAP and Matrix-FDT regarding global indices, GHT, number of defective points, and stage of the visual field damage in mild glaucoma is weak, Matrix-FDT cannot be used interchangeably with SITA-SAP in the early stages of glaucoma.

  20. Factors that influence standard automated perimetry test results in glaucoma: test reliability, technician experience, time of day, and season.

    Science.gov (United States)

    Junoy Montolio, Francisco G; Wesselink, Christiaan; Gordijn, Marijke; Jansonius, Nomdo M

    2012-10-09

    To determine the influence of several factors on standard automated perimetry test results in glaucoma. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician experience, time of day, and season on the mean deviation (MD) was determined by performing linear regression analysis of MD against time on a series of visual fields and subsequently performing a multiple linear regression analysis with the MD residuals as dependent variable and the factors mentioned above as independent variables. Analyses were performed with and without adjustment for the test reliability (fixation losses and false-positive and false-negative answers) and with and without stratification according to disease stage (baseline MD). Mean follow-up was 9.4 years, with on average 10.8 tests per patient. Technician experience, time of day, and season were associated with the MD. Approximately 0.2 dB lower MD values were found for inexperienced technicians (P Technician experience, time of day, season, and the percentage of false-positive answers have a significant influence on the MD of standard automated perimetry.

  1. Comparison between the Correlations of Retinal Nerve Fiber Layer Thickness Measured by Spectral Domain Optical Coherence Tomography and Visual Field Defects in Standard Automated White-on-White Perimetry versus Pulsar Perimetry.

    Science.gov (United States)

    Alnawaiseh, Maged; Hömberg, Lisann; Eter, Nicole; Prokosch, Verena

    2017-01-01

    To compare the structure-function relationships between retinal nerve fiber layer thickness (RNFLT) and visual field defects measured either by standard automated perimetry (SAP) or by Pulsar perimetry (PP). 263 eyes of 143 patients were prospectively included. Depending on the RNFLT, patients were assigned to the glaucoma group (group A: RNFL score 3-6) or the control group (group B: RNFL score 0-2). Structure-function relationships between RNFLT and mean sensitivity (MS) measured by SAP and PP were analyzed. Throughout the entire group, the MS assessed by PP and SAP correlated significantly with RNFLT in all sectors. In the glaucoma group, there was no significant difference between the correlations RNFL-SAP and RNFL-PP, whereas a significant difference was found in the control group. In the control group, the correlation between structure and function based on the PP data was significantly stronger than that based on SAP.

  2. Comparison of visual field test results obtained through Humphrey matrix frequency doubling technology perimetry versus standard automated perimetry in healthy children.

    Science.gov (United States)

    Kocabeyoglu, Sibel; Uzun, Salih; Mocan, Mehmet Cem; Bozkurt, Banu; Irkec, Murat; Orhan, Mehmet

    2013-10-01

    The aim of this study was to compare the visual field test results in healthy children obtained via the Humphrey matrix 24-2 threshold program and standard automated perimetry (SAP) using the Swedish interactive threshold algorithm (SITA)-Standard 24-2 test. This prospective study included 55 healthy children without ocular or systemic disorders who underwent both SAP and frequency doubling technology (FDT) perimetry visual field testing. Visual field test reliability indices, test duration, global indices (mean deviation [MD], and pattern standard deviation [PSD]) were compared between the 2 tests using the Wilcoxon signed-rank test and paired t-test. The performance of the Humphrey field analyzer (HFA) 24-2 SITA-standard and frequency-doubling technology Matrix 24-2 tests between genders were compared with Mann-Whitney U-test. Fifty-five healthy children with a mean age of 12.2 ± 1.9 years (range from 8 years to 16 years) were included in this prospective study. The test durations of SAP and FDT were similar (5.2 ± 0.5 and 5.1 ± 0.2 min, respectively, P = 0.651). MD and the PSD values obtained via FDT Matrix were significantly higher than those obtained via SAP (P tests in terms of MD (r = 0.352, P = 0.008) and PSD (r = 0.329, P = 0.014) was observed. Children were able to complete both the visual test algorithms successfully within 6 min. However, SAP testing appears to be associated with less depression of the visual field indices of healthy children. FDT Matrix and SAP should not be used interchangeably in the follow-up of children.

  3. Short wavelength FELS

    International Nuclear Information System (INIS)

    Sheffield, R.L.

    1991-01-01

    The generation of coherent ultraviolet and shorter wavelength light is presently limited to synchrotron sources. The recent progress in the development of brighter electron beams enables the use of much lower energy electron rf linacs to reach short-wavelengths than previously considered possible. This paper will summarize the present results obtained with synchrotron sources, review proposed short- wavelength FEL designs and then present a new design which is capable of over an order of magnitude higher power to the extreme ultraviolet. 17 refs., 10 figs

  4. Short wavelength FELS

    Energy Technology Data Exchange (ETDEWEB)

    Sheffield, R.L.

    1991-01-01

    The generation of coherent ultraviolet and shorter wavelength light is presently limited to synchrotron sources. The recent progress in the development of brighter electron beams enables the use of much lower energy electron rf linacs to reach short-wavelengths than previously considered possible. This paper will summarize the present results obtained with synchrotron sources, review proposed short- wavelength FEL designs and then present a new design which is capable of over an order of magnitude higher power to the extreme ultraviolet. 17 refs., 10 figs.

  5. Comparison of visual field test results obtained through Humphrey matrix frequency doubling technology perimetry versus standard automated perimetry in healthy children

    Directory of Open Access Journals (Sweden)

    Sibel Kocabeyoglu

    2013-01-01

    Full Text Available Aims : The aim of this study was to compare the visual field test results in healthy children obtained via the Humphrey matrix 24-2 threshold program and standard automated perimetry (SAP using the Swedish interactive threshold algorithm (SITA-Standard 24-2 test. Materials and Methods: This prospective study included 55 healthy children without ocular or systemic disorders who underwent both SAP and frequency doubling technology (FDT perimetry visual field testing. Visual field test reliability indices, test duration, global indices (mean deviation [MD], and pattern standard deviation [PSD] were compared between the 2 tests using the Wilcoxon signed-rank test and paired t-test. The performance of the Humphrey field analyzer (HFA 24-2 SITA-standard and frequency-doubling technology Matrix 24-2 tests between genders were compared with Mann-Whitney U-test. Results: Fifty-five healthy children with a mean age of 12.2 ± 1.9 years (range from 8 years to 16 years were included in this prospective study. The test durations of SAP and FDT were similar (5.2 ± 0.5 and 5.1 ± 0.2 min, respectively, P = 0.651. MD and the PSD values obtained via FDT Matrix were significantly higher than those obtained via SAP (P < 0.001, and fixation losses and false negative errors were significantly less with SAP (P < 0.05. A weak positive correlation between the two tests in terms of MD (r = 0.352, P = 0.008 and PSD (r = 0.329, P = 0.014 was observed. Conclusion: Children were able to complete both the visual test algorithms successfully within 6 min. However, SAP testing appears to be associated with less depression of the visual field indices of healthy children. FDT Matrix and SAP should not be used interchangeably in the follow-up of children.

  6. Sensitivity and specificity of machine learning classifiers for glaucoma diagnosis using Spectral Domain OCT and standard automated perimetry

    Directory of Open Access Journals (Sweden)

    Fabrício R. Silva

    2013-06-01

    Full Text Available PURPOSE: To evaluate the sensitivity and specificity of machine learning classifiers (MLCs for glaucoma diagnosis using Spectral Domain OCT (SD-OCT and standard automated perimetry (SAP. METHODS: Observational cross-sectional study. Sixty two glaucoma patients and 48 healthy individuals were included. All patients underwent a complete ophthalmologic examination, achromatic standard automated perimetry (SAP and retinal nerve fiber layer (RNFL imaging with SD-OCT (Cirrus HD-OCT; Carl Zeiss Meditec Inc., Dublin, California. Receiver operating characteristic (ROC curves were obtained for all SD-OCT parameters and global indices of SAP. Subsequently, the following MLCs were tested using parameters from the SD-OCT and SAP: Bagging (BAG, Naive-Bayes (NB, Multilayer Perceptron (MLP, Radial Basis Function (RBF, Random Forest (RAN, Ensemble Selection (ENS, Classification Tree (CTREE, Ada Boost M1(ADA,Support Vector Machine Linear (SVML and Support Vector Machine Gaussian (SVMG. Areas under the receiver operating characteristic curves (aROC obtained for isolated SAP and OCT parameters were compared with MLCs using OCT+SAP data. RESULTS: Combining OCT and SAP data, MLCs' aROCs varied from 0.777(CTREE to 0.946 (RAN.The best OCT+SAP aROC obtained with RAN (0.946 was significantly larger the best single OCT parameter (p<0.05, but was not significantly different from the aROC obtained with the best single SAP parameter (p=0.19. CONCLUSION: Machine learning classifiers trained on OCT and SAP data can successfully discriminate between healthy and glaucomatous eyes. The combination of OCT and SAP measurements improved the diagnostic accuracy compared with OCT data alone.

  7. Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses.

    Science.gov (United States)

    Hirasawa, Kazunori; Ito, Hikaru; Ohori, Yukari; Takano, Yui; Shoji, Nobuyuki

    2017-01-01

    To evaluate the refractive correction for standard automated perimetry (SAP) in eyes with refractive multifocal contact lenses (CL) in healthy young participants. Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline); multifocal CL corrected for distance (mCL-D); and mCL-D corrected for near vision using a spectacle lens (mCL-N). Primary outcome measures were the foveal threshold, mean deviation (MD), and pattern standard deviation (PSD). The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB ( P correction without additional near correction is to be recommended.

  8. Towards short wavelengths FELs workshop

    International Nuclear Information System (INIS)

    Ben-Zvi, I.; Winick, H.

    1993-01-01

    This workshop was caged because of the growing perception in the FEL source community that recent advances have made it possible to extend FEL operation to wavelengths about two orders of magnitude shorter than the 240 nm that has been achieved to date. In addition short wavelength FELs offer the possibilities of extremely high peak power (several gigawatts) and very short pulses (of the order of 100 fs). Several groups in the USA are developing plans for such short wavelength FEL facilities. However, reviewers of these plans have pointed out that it would be highly desirable to first carry out proof-of-principle experiments at longer wavelengths to increase confidence that the shorter wavelength devices will indeed perform as calculated. The need for such experiments has now been broadly accepted by the FEL community. Such experiments were the main focus of this workshop as described in the following objectives distributed to attendees: (1) Define measurements needed to gain confidence that short wavelength FELs will perform as calculated. (2) List possible hardware that could be used to carry out these measurements in the near term. (3) Define a prioritized FEL physics experimental program and suggested timetable. (4) Form collaborative teams to carry out this program

  9. Towards short wavelengths FELs workshop

    Science.gov (United States)

    Ben-Zvi, I.; Winick, H.

    1993-11-01

    This workshop was caged because of the growing perception in the FEL source community that recent advances have made it possible to extend FEL operation to wavelengths about two orders of magnitude shorter than the 240 nm that has been achieved to date. In addition short wavelength FEL's offer the possibilities of extremely high peak power (several gigawatts) and very short pulses (of the order of 100 fs). Several groups in the USA are developing plans for such short wavelength FEL facilities. However, reviewers of these plans have pointed out that it would be highly desirable to first carry out proof-of-principle experiments at longer wavelengths to increase confidence that the shorter wavelength devices will indeed perform as calculated. The need for such experiments has now been broadly accepted by the FEL community. Such experiments were the main focus of this workshop as described in the following objectives distributed to attendees: (1) Define measurements needed to gain confidence that short wavelength FEL's will perform as calculated. (2) List possible hardware that could be used to carry out these measurements in the near term. (3) Define a prioritized FEL physics experimental program and suggested timetable. (4) Form collaborative teams to carry out this program.

  10. Effect of multizone refractive multifocal contact lenses on standard automated perimetry.

    Science.gov (United States)

    Madrid-Costa, David; Ruiz-Alcocer, Javier; García-Lázaro, Santiago; Albarrán-Diego, César; Ferrer-Blasco, Teresa

    2012-09-01

    The aim of this study was to evaluate whether the creation of 2 foci (distance and near) provided by multizone refractive multifocal contact lenses (CLs) for presbyopia correction affects the measurements on Humphreys 24-2 Swedish interactive threshold algorithm (SITA) standard automated perimetry (SAP). In this crossover study, 30 subjects were fitted in random order with either a multifocal CL or a monofocal CL. After 1 month, a Humphrey 24-2 SITA standard strategy was performed. The visual field global indices (the mean deviation [MD] and pattern standard deviation [PSD]), reliability indices, test duration, and number of depressed points deviating at P0.5% on pattern deviation probability plots were determined and compared between multifocal and monofocal CLs. Thirty eyes of 30 subjects were included in this study. There were no statistically significant differences in reliability indices or test duration. There was a statistically significant reduction in the MD with the multifocal CL compared with monfocal CL (P=0.001). Differences were not found in PSD nor in the number of depressed points deviating at P0.5% in the pattern deviation probability maps studied. The results of this study suggest that the multizone refractive lens produces a generalized depression in threshold sensitivity as measured by the Humphreys 24-2 SITA SAP.

  11. Flicker-defined form perimetry in glaucoma patients.

    Science.gov (United States)

    Horn, Folkert K; Kremers, Jan; Mardin, Christian Y; Jünemann, Anselm G; Adler, Werner; Tornow, Ralf P

    2015-03-01

    To assess the potential of flicker-defined form (FDF) perimetry to detect functional loss in patient groups with beginning glaucoma, and to evaluate the dynamic range of the FDF stimulus in individual patients and at individual test positions. FDF perimetry and standard automated perimetry (SAP) were performed at identical test locations (adapted G1 protocol) in 60 healthy subjects and 111 glaucoma patients. All patients showed glaucomatous optic disc appearance. Grouping within the glaucoma cohort was based on SAP-performance: 33 "preperimetric" open-angle glaucoma (OAG) patients, 28 "borderline" OAG (focal defects and SAP-mean defect (MD) <2 dB), 33 "early" OAG (SAP-MD < 5 dB), 17 "advanced" OAG. All participants were experienced in psychophysical and perimetric tests. Defect values and the areas under receiver operating characteristic curves (ROC) in patient groups were statistically compared. The values of FDF-MD in the preperimetric, borderline, and early OAG group were 2.7 ± 3.4 dB, 5.5 ± 2.6 dB, and 8.5 ± 3.4 dB respectively (all significantly above normal). The percentage of patients exceeding normal FDF-MD was 27.3 %, 60.7 %, and 87.9 % respectively. The age-adjusted FDF-mean defect (MD) of the G1X-protocol was not significantly correlated with refractive error, lens opacity, pupil size, or gender. Occurrence of ceiling effects (inability to detect targets at highest contrast) showed a high correlation with visual field losses (R = 0.72, p < 0.001). Local analysis indicates that SAP losses exceeding 5 dB could not be distinguished with the FDF technique. The FDF stimulus was able to detect beginning glaucoma damage. Patients with SAP-MD values exceeding 5 dB should be monitored with conventional perimetry because of its larger dynamic range.

  12. Comparison of Peristat Online Perimetry with the Humphrey Perimetry in a Clinic-Based Setting

    OpenAIRE

    Lowry, Eugene A.; Hou, Jing; Hennein, Lauren; Chang, Robert T.; Lin, Shan; Keenan, Jeremy; Wang, Sean K.; Ianchulev, Sean; Pasquale, Louis R.; Han, Ying

    2016-01-01

    Purpose We determined the receiver operating characteristic (ROC) curves for Peristat online perimetry at detecting varying degrees of glaucoma and the correlation between Peristat online perimetry and Humphrey visual field. Methods: A prospective, comparative study of Peristat online perimetry (an achromatic static computer threshold testing program) and Humphrey visual field (HVF) 24-2 SITA standard testing was performed by 63 glaucoma patients and 30 healthy controls in random order. The n...

  13. Eye movement perimetry in glaucoma.

    Science.gov (United States)

    Trope, G E; Eizenman, M; Coyle, E

    1989-08-01

    Present-day computerized perimetry is often inaccurate and unreliable owing to the need to maintain central fixation over long periods while repressing the normal response to presentation of peripheral stimuli. We tested a new method of perimetry that does not require prolonged central fixation. During this test eye movements were encouraged on presentation of a peripheral target. Twenty-three eyes were studied with an Octopus perimeter, with a technician monitoring eye movements. The sensitivity was 100% and the specificity 23%. The low specificity was due to the technician's inability to accurately monitor small eye movements in the central 6 degrees field. If small eye movements are monitored accurately with an eye tracker, eye movement perimetry could become an alternative method to standard perimetry.

  14. [Assessment of the macula function by static perimetry, microperimetry and rarebit perimetry in patients suffering from dry age related macular degeneration].

    Science.gov (United States)

    Nowomiejska, Katarzyna; Oleszczuk, Agnieszka; Zubilewicz, Anna; Krukowski, Jacek; Mańkowska, Anna; Rejdak, Robert; Zagórski, Zbigniew

    2007-01-01

    To compare the visual field results obtained by static perimetry, microperimetry and rabbit perimetry in patients suffering from dry age related macular degeneration (AMD). Fifteen eyes with dry AMD (hard or soft macula drusen and RPE disorders) were enrolled into the study. Static perimetry was performed using M2 macula program included in Octopus 101 instrument. Microperimetry was performed using macula program (14-2 threshold, 10dB) within 10 degrees of the central visual field. The fovea program within 4 degrees was used while performing rarebit perimetry. The mean sensitivity was significantly lower (p<0.001) during microperimetry (13.5 dB) comparing to static perimetry (26.7 dB). The mean deviation was significantly higher (p<0.001) during microperimetry (-6.32 dB) comparing to static perimetry (-3.11 dB). The fixation was unstable in 47% and eccentric in 40% while performing microperimetry. The median of the "mean hit rate" in rarebit perimetry was 90% (range 40-100%). The mean examination duration was 6.5 min. in static perimetry, 10.6 min. in microperimetry and 5,5 min. in rarebit perimetry (p<0.001). Sensitivity was 30%, 53% and 93% respectively. The visual field defects obtained by microperimetry were more pronounced than those obtained by static perimetry. Microperimetry was the most sensitive procedure although the most time-consuming. Microperimetry enables the control of the fixation position and stability, that is not possible using the remaining methods. Rarebit perimetry revealed slight reduction of the integrity of neural architecture of the retina. Microperimetry and rarebit perimetry provide more information in regard to the visual function than static perimetry, thus are the valuable method in the diagnosis of dry AMD.

  15. Is oculokinetic perimetry useful?

    Science.gov (United States)

    Abreu Reyes, J A; Gonzalez de la Rosa, M; Sanchez Mendez, M; Mesa Moreno, C G; Santos Barrera, R

    1992-09-01

    An evaluation was carried out comparing Oculokinetic Perimetry (O.K.P.) with Automatic Perimetry of Thresholds (Hipocampus Perimeter) for ocular hypertension and glaucoma studying 145 eyes. The O.K.P. shows a sensitivity between 35.65 and 38.54%, a specificity of 76.67-79.59%, a + predictive value of 78.72-85.42%, and a-predictive value of 23.71-39.80%.

  16. Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses

    Directory of Open Access Journals (Sweden)

    Kazunori Hirasawa

    2017-10-01

    Full Text Available AIM: To evaluate the refractive correction for standard automated perimetry (SAP in eyes with refractive multifocal contact lenses (CL in healthy young participants. METHODS: Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline; multifocal CL corrected for distance (mCL-D; and mCL-D corrected for near vision using a spectacle lens (mCL-N. Primary outcome measures were the foveal threshold, mean deviation (MD, and pattern standard deviation (PSD. RESULTS: The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB CONCLUSION: Despite the induced mydriasis and the optical design of the multifocal lens used in this study, our results indicated that, when the dome-shaped visual field test is performed with eyes with large pupils and wearing refractive multifocal CLs, distance correction without additional near correction is to be recommended.

  17. [Comparing the ranges of defect measured with standard white on white and Pulsar perimetries].

    Science.gov (United States)

    González de la Rosa, M; González-Hernández, M; García-Feijoo, J; Sánchez Méndez, M; García-Sánchez, J

    2011-04-01

    Normal thresholds on Pulsar perimetry fall faster than those of standard perimetry in the peripheral visual field. Two related studies were performed. Firstly, the frequency distributions of glaucoma defects on standard automated perimetry (SAP) and the relationship of the centre and periphery (Study A) were studied first, followed by an attempt to establish the limits of pulsar perimetry (Study B). A: frequency of defects was calculated in 78.663 SAP perimetries (G1-TOP, Octopus 1-2-3, Haag-Streit). Study B: 204 eyes with mean defect (MD-SAP) lower than 9 dB were examined 8.92 ± 4.19 times with SAP (TOP-32, Octopus 311) and temporal modulation perimetry (T30W, Pulsar Perimeter, Haag-Streit). Study A: 50.7% of the SAP examinations showed MD values lower than 9 dB and 32.7% bellow 6 dB. The MD correlation of the central 20° with the MD of the most peripheral points was r=0.933. Study B: in cases with MD-TOP-32 lower than 6 dB, SAP had the maximum possibility of detecting defect in 0.02% of points and Pulsar in 0.29%. In subjects with MD-TOP-32 between 6 and 9 dB frequencies were 0.38% in SAP and 3.5% in Pulsar (5.1% for eccentricities higher than 20°). Pulsar allows detecting defects, without range limitations, in the initial half of SAP frequencies expected on glaucoma patients. In order to study the progression of deeper defects the examination should focus on the central points, where the dynamic range of both systems is more equivalent. Copyright © 2010 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  18. Perimetric measurements with flicker-defined form stimulation in comparison with conventional perimetry and retinal nerve fiber measurements.

    Science.gov (United States)

    Horn, Folkert K; Tornow, Ralf P; Jünemann, Anselm G; Laemmer, Robert; Kremers, Jan

    2014-04-11

    We compared the results of flicker-defined form (FDF) perimetry with standard automated perimetry (SAP) and retinal nerve fiber layer (RNFL) thickness measurements using spectral domain optical coherence tomography (OCT). A total of 64 healthy subjects, 45 ocular hypertensive patients, and 97 "early" open-angle glaucoma (OAG) patients participated in this study. Definition of glaucoma was based exclusively on glaucomatous optic disc appearance. All subjects underwent FDF perimetry, SAP, and peripapillary measurements of the RNFL thickness. The FDF perimetry and SAP were performed at identical test locations (G1 protocol). Exclusion criteria were subjects younger than 34 years, SAP mean defect (SAP MD) > 5 dB, eye diseases other than glaucoma, or nonreliable FDF measurements. The correlations between the perimetric data on one hand and RNFL thicknesses on the other hand were analyzed statistically. The age-corrected sensitivity values and the local results from the controls were used to determine FDF mean defect (FDF MD). The FDF perimetry and SAP showed high concordance in this cohort of experienced patients (MD values, R = -0.69, P < 0.001). Of a total of 42 OAG patients with abnormal SAP MD, 38 also displayed abnormal FDF MD. However, FDF MD was abnormal in 28 of 55 OAG patients with normal SAP MD. The FDF MD was significantly (R = -0.61, P < 0.001) correlated with RNFL thickness with a (nonsignificantly) larger correlation coefficient than conventional SAP MD (R = -0.48, P < 0.001). The FDF perimetry is able to uncover functional changes concurrent with the changes in RNFL thickness. The FDF perimetry may be an efficient functional test to detect early glaucomatous nerve atrophy. (ClinicalTrials.gov number, NCT00494923.).

  19. An automated wavelength selection for flame spectroscopy

    International Nuclear Information System (INIS)

    Hurteau, M.; Mislan, J.P.; Ashley, R.W.

    1976-01-01

    A simple electro-mechanical programming system is described for use with a flame spectrophotometer. Its application for automated sequential multi-element analysis is illustrated. Reproducibility of wavelength settings are within +-0.5 A. Precision and sensitivities are at least as good as those obtained for single element determinations. (author)

  20. Short wavelength FELs using the SLAC linac

    International Nuclear Information System (INIS)

    Winick, H.; Bane, K.; Boyce, R.

    1993-08-01

    Recent technological developments have opened the possibility to construct a device which we call a Linac Coherent Light Source (LCLS); a fourth generation light source, with brightness, coherence, and peak power far exceeding other sources. Operating on the principle of the free electron laser (FEL), the LCLS would extend the range of FEL operation to much aborter wavelength than the 240 mn that has so far been reached. We report the results of studies of the use of the SLAC linac to drive an LCLS at wavelengths from about 3-100 nm initially and possibly even shorter wavelengths in the future. Lasing would be achieved in a single pass of a low emittance, high peak current, high energy electron beam through a long undulator. Most present FELs use an optical cavity to build up the intensity of the light to achieve lasing action in a low gain oscillator configuration. By eliminating the optical cavity, which is difficult to make at short wavelengths, laser action can be extended to shorter wavelengths by Self-Amplified-Spontaneous-Emission (SASE), or by harmonic generation from a longer wavelength seed laser. Short wavelength, single pass lasers have been extensively studied at several laboratories and at recent workshops

  1. Review of short wavelength lasers

    International Nuclear Information System (INIS)

    Hagelstein, P.L.

    1985-01-01

    There has recently been a substantial amount of research devoted to the development of short wavelength amplifiers and lasers. A number of experimental results have been published wherein the observation of significant gain has been claimed on transitions in the EUV and soft x-ray regimes. The present review is intended to discuss the main approaches to the creation of population inversions and laser media in the short wavelength regime, and hopefully aid workers in the field by helping to provide access to a growing literature. The approaches to pumping EUV and soft x-ray lasers are discussed according to inversion mechanism. The approaches may be divided into roughly seven categories, including collisional excitation pumping, recombination pumping, direct photoionization and photoexcitation pumping, metastable state storage plus optical pumping, charge exchange pumping, and finally, the extension of free electron laser techniques into the EUV and soft x-ray regimes. 250 references

  2. Review of short wavelength lasers

    Energy Technology Data Exchange (ETDEWEB)

    Hagelstein, P.L.

    1985-03-18

    There has recently been a substantial amount of research devoted to the development of short wavelength amplifiers and lasers. A number of experimental results have been published wherein the observation of significant gain has been claimed on transitions in the EUV and soft x-ray regimes. The present review is intended to discuss the main approaches to the creation of population inversions and laser media in the short wavelength regime, and hopefully aid workers in the field by helping to provide access to a growing literature. The approaches to pumping EUV and soft x-ray lasers are discussed according to inversion mechanism. The approaches may be divided into roughly seven categories, including collisional excitation pumping, recombination pumping, direct photoionization and photoexcitation pumping, metastable state storage plus optical pumping, charge exchange pumping, and finally, the extension of free electron laser techniques into the EUV and soft x-ray regimes. 250 references.

  3. Relationship Between Motor Vehicle Collisions and Results of Perimetry, Useful Field of View, and Driving Simulation in Drivers With Glaucoma

    NARCIS (Netherlands)

    Tatham, AJ; Boer, E.R.; Gracitelli, CPB; Rosen, PN; Medeiros, FA

    2015-01-01

    Purpose: To examine the relationship between Motor Vehicle Collisions (MVCs) in
    drivers with glaucoma and standard automated perimetry (SAP), Useful Field of View
    (UFOV), and driving simulator assessment of divided attention.
    Methods: A cross-sectional study of 153 drivers from the

  4. Comparing the Structure-Function Relationship at the Macula With Standard Automated Perimetry and Microperimetry.

    Science.gov (United States)

    Rao, Harsha L; Januwada, Manideepak; Hussain, Raza S M; Pillutla, Lalitha N; Begum, Viquar U; Chaitanya, Aditya; Senthil, Sirisha; Garudadri, Chandra S

    2015-12-01

    To compare the structure-function relationship between ganglion cell-inner plexiform layer (GCIPL) thickness measurements using spectral-domain optical coherence tomography (SDOCT) and visual sensitivities measured using standard automated perimetry (SAP) and microperimetry (MP) at the macula in glaucoma. In a prospective study, 45 control eyes (29 subjects) and 60 glaucoma eyes (45 patients) underwent visual sensitivity estimation at the macula (central 10°) by SAP and MP, and GCIPL thickness measurement at the macula by SDOCT. Structure-function relationships between GCILP thickness and visual sensitivity loss with SAP and MP at various macular sectors were assessed using the Hood and Kardon model. To compare structure-function relationship with SAP and MP, we calculated the number of data points falling outside the 5th and the 95th percentile values of the Hood and Kardon model with each of the perimeters. The number of points falling outside the 5th and 95th percentile values of the Hood and Kardon model ranged from 28 (superior sector) to 48 (inferonasal sector) with SAP and 33 (superior sector) to 49 (inferonasal sector) with MP. The difference in the number of points falling outside the 5th and 95th percentile values with SAP and MP was statistically insignificant (P > 0.05, χ(2) test) for all the sectors. Visual sensitivity measurements of both SAP and MP demonstrated a similar relationship with the GCIPL measurements of SDOCT at the macula in glaucoma.

  5. Short wavelength sources and atoms and ions

    International Nuclear Information System (INIS)

    Kennedy, E.T.

    2008-01-01

    The interaction of ionizing radiation with atoms and ions is a key fundamental process. Experimental progress has depended in particular on the development of short wavelength light sources. Laser-plasma and synchrotron sources have been exploited for several decades and most recently the development of short wavelength Free Electron Laser (FEL) sources is revolutionizing the field. This paper introduces laser plasma and synchrotron sources through examples of their use in studies of the interaction of ionizing radiation with atoms and ions, ranging from few-electron atomic and ionic systems to the many-electron high atomic number actinides. The new FEL source (FLASH) at DESY is introduced. (author)

  6. Automated dual-wavelength spectrophotometer optimized for phytochrome assay

    International Nuclear Information System (INIS)

    Pratt, L.H.; Wampler, J.E.; Rich, E.S. Jr.

    1985-01-01

    A microcomputer-controlled dual-wavelength spectrophotometer suitable for automated phytochrome assay is described. The optomechanical unit provides for sequential irradiation of the sample by the two measuring wavelengths with intervening dark intervals and for actinic irradiation to interconvert phytochrome between its two forms. Photomultiplier current is amplified, converted to a digital value and transferred into the computer using a custom-designed IEEE-488 bus interface. The microcomputer calculates mathematically both absorbance and absorbance difference values with dynamic correction for photomultiplier dark current. In addition, the computer controls the operating parameters of the spectrophotometer via a separate interface. These parameters include control of the durations of measuring and actinic irradiation intervals and their sequence. 14 references, 4 figures

  7. Volume of visual field assessed with kinetic perimetry and its application to static perimetry

    Directory of Open Access Journals (Sweden)

    Christoforidis JB

    2011-04-01

    Full Text Available John B ChristoforidisCollege of Medicine, The Ohio State University, Columbus, OH, USABackground: The purpose of this study was to quantify the volume of the kinetic visual field with a single unit that accounts for visual field area and differential luminance sensitivity.Methods: Kinetic visual field perimetry was performed with a Goldmann perimeter using I4e, I3e, I2e, and I1e targets. The visual fields of 25 normal volunteers (17 women, eight men of mean age 33.9 ± 10.1 (range 17–64 years were obtained and digitized. Isopter areas were measured with a method devised to correct cartographic distortion due to polar projection inherent in perimetry and are expressed in steradians. The third dimension of each isopter represents sensitivity to target luminance and was calculated as log (target luminance-1. If luminance is expressed in cd/m2, the values for the third dimension are 0.5 for I4e, 1.0 for I3e, 1.5 for I2e, and 2.0 for I1e. The resulting unit is a steradian (log 103 (cd/m2-1 which is referred to as a Goldmann. In addition, the visual fields of four patients with representative visual defect patterns were examined and compared with normal subjects.Results: Mean isopter areas for normal subjects were 3.092 ± 0.242 steradians for I4e, 2.349 ± 0.280 steradians for I3e, 1.242 ± 0.263 steradians for I2e, and 0.251 ± 0.114 steradians for the I1e target. Isopter volumes were 1.546 ± 0.121 Goldmanns for the I4e target, 1.174 ± 0.140 Goldmanns for I3e, 0.621 ± 0.131 Goldmanns for I2e, and 0.126 ± 0.057 Goldmanns for I1e. The total mean visual field volume in our study for the I target was 3.467 ± 0.371 Goldmanns.Conclusion: The volume of the island of vision may be used to quantify a visual field with a single value which contains information about both visual field extension and differential luminance sensitivity. This technique may be used to assess the progression or stability of visual field defects over time. A similar method may

  8. Self-amplified spontaneous emission for short wavelength coherent radiation

    International Nuclear Information System (INIS)

    Kim, K.J.; Xie, M.

    1992-09-01

    We review the recent progress in our understanding of the self-amplified spontaneous emission (SASE), emphasizing the application to short wavelength generation. Simple formulae are given for the start-up, exponential gain and the saturation of SASE. Accelerator technologies producing high brightness electron beams required for short wavelength SASE are discussed. An example utilizing electron beams from a photocathode-linac system to produce 4nm SASE in the multigigawatt range is presented

  9. Pulsar perimetry in the diagnosis of early glaucoma.

    Science.gov (United States)

    Zeppieri, Marco; Brusini, Paolo; Parisi, Lucia; Johnson, Chris A; Sampaolesi, Roberto; Salvetat, Maria Letizia

    2010-01-01

    To assess the ability of Pulsar perimetry (Pulsar) in detecting early glaucomatous visual field (VF) damage in comparison with Frequency Doubling Technology (FDT), Scanning Laser Polarimetry (SLP, GDx VCC), and Heidelberg Retina Tomography (HRT). Prospective observational cross-sectional case study. This multicenter study included: 87 ocular hypertensives (OHT); 67 glaucomatous optic neuropathy (GON) patients; 75 primary open-angle glaucoma (POAG) patients; and 90 normals. All patients underwent standard automated perimetry (SAP) HFA 30-2, Pulsar T30W, FDT N-30, HRT II, and GDx VCC. Area under Receiver Operating Characteristic Curves (AROCs) for discriminating between healthy and glaucomatous eyes and agreement among instruments were determined. The best parameters for Pulsar, FDT, HRT, and GDx were, respectively: loss variance square root; no. of areas with PPulsar (AROC, 0.90) appeared comparable with FDT (0.89) and significantly better than HRT (0.82) and GDx (0.79). For GON, Pulsar ability (0.74) was higher than GDx (0.69) and lower than FDT (0.80) and HRT (0.83). The agreement among instruments ranged from 0.12 to 0.56. Pulsar test duration was significantly shorter than SAP and FDT (PPulsar T30W test is a rapid and easy perimetric method, showing higher sensitivity than SAP in detecting early glaucomatous VF loss. Its diagnostic ability is good for detecting early perimetric POAG eyes and fair for GON eyes. Pulsar performance was comparable with FDT, HRT, and GDx, even if the agreement between instruments was poor to fair. Copyright 2010 Elsevier Inc. All rights reserved.

  10. PATTERN ELECTRORETINOGRAPHY IN RELATION TO KINETIC AND STATIC PERIMETRY AND VISUAL ACUITY IN RETINITIS PIGMENTOSA

    Directory of Open Access Journals (Sweden)

    Petra Popović

    2002-12-01

    Full Text Available Background. This study was conducted to assess whether pattern ERG is a sensitive test in evaluating the retinal function in patients with retinitis pigmentosa. We wanted to determine how pattern ERG, reflecting the activity of inner retinal layers, is related to other psychophysical tests such as perimetry and visual acuity.Methods. An analysis was performed on 50 eyes of 25 patients with typical rod-cone retinitis pigmentosa. The standard Snellen visual acuity was tested. Visual field sensitivity was measured with automated static perimetry (Octopus G2 program where mean defect was taken as an index of visual field loss. In kinetic perimetry (Goldmann the average radius of the visual field measured with target II/4 and V/4 was calculated. Transient pattern ERG and all five flash ERG responses were also measured according to ISCEV standards. Amplitudes of pattern ERG P50 and N95 waves were compared to results of visual acuity and visual field testing.Results. In our group of 25 RP patients with visual acuity ranging from 0.16 to 1.0, PERG responses were preserved much better than full field ERGs. 72% of them had still recordable PERG responses, while 48% had cone and only 32% maximal responses. Scotopic rod responses were extinguished in all eyes. The normalized amplitudes of the PERG responses were also much higher (43.5% than cone (22.5% or maximal responses (4.5%. A strong correlation of both P50 and N95 amplitudes with Octopus mean defect index was found. In kinetic perimetry the correlation with PERG amplitudes was also high, but it was better with II/4 than with V/4 target. Patients with high preserved ERG responses had good visual acuity. In all patients with visual acuity less than 0.4 both flash and pattern ERG responses were already absent.Conclusions. This study shows that pattern ERG is an objective and sensitive test in evaluating the functional visual loss in retinitis pigmentosa. Amplitudes of P50 and N95 responses are linearly

  11. Effects of different levels of intraocular stray light on kinetic perimetry findings.

    Directory of Open Access Journals (Sweden)

    Kazunori Hirasawa

    Full Text Available To evaluate the effect of different levels of intraocular stray light on kinetic perimetry findings.Twenty-five eyes of 25 healthy young participants were examined by automated kinetic perimetry (Octopus 900 using Goldmann stimuli III4e, I4e, I3e, I2e, and I1e. Each stimulus was presented with a velocity of 3°/s at 24 meridians with 15° intervals. Four levels of intraocular stray light were induced using non-white opacity filter (WOF filters and WOFs applied to the clear plastic eye covers of the participants. The visual acuity, pupil diameter, isopter area, and kinetic sensitivity of each meridian were analyzed for each WOF density.Visual acuity deteriorated with increasing WOF densities (p < 0.01. With a visual acuity of 0.1 LogMAR units, the isopter areas for III4e, I4e, I3e, I2e, and I1e decreased by -32.7 degree2 (-0.2%, -255.7 degree2 (-2.6%, -381.2 degree2 (-6.2%, -314.8 degree2 (-12.8%, and -59.2 degree2 (-15.2%, respectively; kinetic sensitivity for those stimuli decreased by -0.1 degree (-0.1%, -0.8 degree (-1.4%, -1.6 degree (-3.7%, -2.7 degree (-9.7%, and -1.7 degree (-16.2%, respectively. The pupil diameter with each WOF density was not significantly different.Kinetic perimetry measurements with a high-intensity stimulus (i.e., III4e were unaffected by intraocular stray light. In contrast, measurements with the I4e, I3e, I2e, and I1e stimuli, especially I2e and I1e, were affected. Changes in the shape of the isopter resulting from opacity must be monitored, especially in cases of smaller and lower-intensity stimuli.

  12. Local Analysis Approach for Short Wavelength Geopotential Variations

    Science.gov (United States)

    Bender, P. L.

    2009-12-01

    The value of global spherical harmonic analyses for determining 15 day to 30 day changes in the Earth's gravity field has been demonstrated extensively using data from the GRACE mission and previous missions. However, additional useful information appears to be obtainable from local analyses of the data. A number of such analyses have been carried out by various groups. In the energy approximation, the changes in the height of the satellite altitude geopotential can be determined from the post-fit changes in the satellite separation during individual one-revolution arcs of data from a GRACE-type pair of satellites in a given orbit. For a particular region, it is assumed that short wavelength spatial variations for the arcs crossing that region during a time T of interest would be used to determine corrections to the spherical harmonic results. The main issue in considering higher measurement accuracy in future missions is how much improvement in spatial resolution can be achieved. For this, the shortest wavelengths that can be determined are the most important. And, while the longer wavelength variations are affected by mass distribution changes over much of the globe, the shorter wavelength ones hopefully will be determined mainly by more local changes in the mass distribution. Future missions are expected to have much higher accuracy for measuring changes in the satellite separation than GRACE. However, how large an improvement in the derived results in hydrology will be achieved is still very much a matter of study, particularly because of the effects of uncertainty in the time variations in the atmospheric and oceanic mass distributions. To be specific, it will be assumed that improving the spatial resolution in continental regions away from the coastlines is the objective, and that the satellite altitude is in the range of roughly 290 to 360 km made possible for long missions by drag-free operation. The advantages of putting together the short wavelength

  13. Validity and cost-effectiveness of methods for screening of primary open angle glaucoma

    Directory of Open Access Journals (Sweden)

    Fröschl, Barbara

    2007-02-01

    Full Text Available Health political background: About 950,000 people are affected by glaucoma in Germany, about 50% of which are undiagnosed. The German Ophthalmological Society and the German Association of Ophthalmologists recommend a screening for glaucoma according to their guidelines. The Federal Joint Committee disapproved a glaucoma-screening program on expense of the compulsory health insurance in 2004. Scientific background: Primary open angle glaucoma is diagnosed by evaluation of the optic disc, the retinal fibre layer and the visual field. The main examinations are ophthalmoscopy, scanning laser polarimetry, confocal scanning laser ophthalmoscopy, retinal thickness analysis and optical coherence tomography. Scotomas are diagnosed by perimetry (standard automated perimetry, short wavelength automated perimetry and frequency doubling perimetry. The intraocular pressure is the most important treatable risk factor and is measured by (contact or non-contact tonometry. Research questions: The aim of this HTA-report is to investigate the diagnostic validity and cost effectiveness of diagnostic techniques or combinations of these methods with respect to the use in a screening setting in Germany. Methods: A systematic literature research was performed in 35 international databases and yielded 2602 articles. Overall 57 publications were included for assessment, according to predefined selection criteria. Results: The 55 medical articles deal mainly with frequency doubling perimetry, confocal scanning laser ophthalmoscopy and scanning laser polarimetry. Few articles cover short wavelength automated perimetry, tonometry and ophalmocopic evaluations by ophthalmologists. The quality of the papers is generally low, as far as the evidence in respect of screening is concerned. No single method exists with both, high sensitivity and high specificity for screening purpose. Data are also not sufficient to recommend combinations of methods. Only two economic models on cost

  14. Comparison of size modulation and conventional standard automated perimetry with the 24-2 test protocol in glaucoma patients

    Science.gov (United States)

    Hirasawa, Kazunori; Shoji, Nobuyuki; Kasahara, Masayuki; Matsumura, Kazuhiro; Shimizu, Kimiya

    2016-05-01

    This prospective randomized study compared test results of size modulation standard automated perimetry (SM-SAP) performed with the Octopus 600 and conventional SAP (C-SAP) performed with the Humphrey Field Analyzer (HFA) in glaucoma patients. Eighty-eight eyes of 88 glaucoma patients underwent SM-SAP and C-SAP tests with the Octopus 600 24-2 Dynamic and HFA 24-2 SITA-Standard, respectively. Fovea threshold, mean defect, and square loss variance of SM-SAP were significantly correlated with the corresponding C-SAP indices (P < 0.001). The false-positive rate was slightly lower, and false-negative rate slightly higher, with SM-SAP than C-SAP (P = 0.002). Point-wise threshold values obtained with SM-SAP were moderately to strongly correlated with those obtained with C-SAP (P < 0.001). The correlation coefficients of the central zone were significantly lower than those of the middle to peripheral zone (P = 0.031). The size and depth of the visual field (VF) defect were smaller (P = 0.039) and greater (P = 0.043), respectively, on SM-SAP than on C-SAP. Although small differences were observed in VF sensitivity in the central zone, the defect size and depth and the reliability indices between SM-SAP and C-SAP, global indices of the two testing modalities were well correlated.

  15. Estimates of SASE power in the short wavelength region

    International Nuclear Information System (INIS)

    Kim, Kwang-Je.

    1992-03-01

    Given a sufficiently bright electron beam, the self-amplified-spontaneous emission (SASE) can provide gigawatts of short wavelength coherent radiation. The advantages of SASE approach are that is requires neither optical cavity nor an imput seed laser. In this note, we estimate the peak power performance of SASE for wavelengths shorter than 1000 Angstrom. At each wavelength, we calculate the saturated power from a uniform parameter undulator and the enhanced power from a tapered undulator. The method described here is an adaptation of that discussed by L.H. Yu, who discussed the harmonic generation scheme with seeded laser, to the case of SASE

  16. OMEGA: a short-wavelength laser for fusion experiments

    International Nuclear Information System (INIS)

    Soures, J.M.; Hutchison, R.J.; Jacobs, S.D.; Lund, L.D.; McCrory, R.L.; Richardson, M.C.

    1983-01-01

    The OMEGA, Nd:glass laser facility was constructed for the purpose of investigating the feasibility of direct-drive laser fusion. With 24 beams producing a total energy of 4 kJ or a peak power of 12 TW, OMEGA is capable of nearly uniform illumination of spherical targets. Six of the OMEGA beams have recently been converted to short-wavelength operation (351 nm). In this paper, we discuss details of the system design and performance, with particular emphasis on the frequency-conversion system and multi-wavelength diagnostic system

  17. Research with high-power short-wavelength lasers

    International Nuclear Information System (INIS)

    Holzrichter, J.F.; Campbell, E.M.; Lindl, J.D.; Storm, E.

    1985-01-01

    Three important high-temperature, high-density experiments were conducted recently using the 10-TW, short-wavelength Novette laser system at the Lawrence Livermore National Laboratory. These experiments demonstrated successful solutions to problems that arose during previous experiments with long wavelength lasers (lambda greater than or equal to 1μm) in which inertial confinement fusion (ICF), x-ray laser, and other high-temperature physics concepts were being tested. The demonstrations were: (1) large-scale plasmas (typical dimensions of up to 1000 laser wavelengths) were produced in which potentially deleterious laser-plasma instabilities were collisionally damped. (2) Deuterium-tritium fuel was imploded to a density of 20 g/cm 3 and a pressure of 10 10 atm. (3) A 700-fold amplification of soft x rays by stimulated emission at 206 and 209 A (62 eV) from Se +24 ions was observed in a laser-generated plasma. Isoelectronic scaling to 155 A (87 eV) in Y +29 was also demonstrated

  18. On the combination of molecular replacement and single-wavelength anomalous diffraction phasing for automated structure determination

    International Nuclear Information System (INIS)

    Panjikar, Santosh; Parthasarathy, Venkataraman; Lamzin, Victor S.; Weiss, Manfred S.; Tucker, Paul A.

    2009-01-01

    The combination of molecular replacement and single-wavelength anomalous diffraction improves the performance of automated structure determination with Auto-Rickshaw. A combination of molecular replacement and single-wavelength anomalous diffraction phasing has been incorporated into the automated structure-determination platform Auto-Rickshaw. The complete MRSAD procedure includes molecular replacement, model refinement, experimental phasing, phase improvement and automated model building. The improvement over the standard SAD or MR approaches is illustrated by ten test cases taken from the JCSG diffraction data-set database. Poor MR or SAD phases with phase errors larger than 70° can be improved using the described procedure and a large fraction of the model can be determined in a purely automatic manner from X-ray data extending to better than 2.6 Å resolution

  19. Relationship between optical coherence tomography, pattern electroretinogram and automated perimetry in eyes with temporal hemianopia from chiasmal compression.

    Science.gov (United States)

    Monteiro, Mário L R; Cunha, Leonardo P; Costa-Cunha, Luciana V F; Maia, Otacílio O; Oyamada, Maria K

    2009-08-01

    To evaluate the relationship between pattern electroretinogram (PERG) amplitude, macular and retinal nerve fiber layer (RNFL) thickness by optical coherence tomography (OCT), and visual field (VF) loss on standard automated perimetry (SAP) in eyes with temporal hemianopia from chiasmal compression. Forty-one eyes from 41 patients with permanent temporal VF defects from chiasmal compression and 41 healthy subjects underwent transient full-field and hemifield (temporal or nasal) stimulation PERG, SAP and time domain-OCT macular and RNFL thickness measurements. Comparisons were made using Student's t-test. Deviation from normal VF sensitivity for the central 18 degrees of VF was expressed in 1/Lambert units. Correlations between measurements were verified by linear regression analysis. PERG and OCT measurements were significantly lower in eyes with temporal hemianopia than in normal eyes. A significant correlation was found between VF sensitivity loss and full-field or nasal, but not temporal, hemifield PERG amplitude. Likewise a significant correlation was found between VF sensitivity loss and most OCT parameters. No significant correlation was observed between OCT and PERG parameters, except for nasal hemifield amplitude. A significant correlation was observed between several macular and RNFL thickness parameters. In patients with chiasmal compression, PERG amplitude and OCT thickness measurements were significant related to VF loss, but not to each other. OCT and PERG quantify neuronal loss differently, but both technologies are useful in understanding structure-function relationship in patients with chiasmal compression. (ClinicalTrials.gov number, NCT00553761).

  20. Nonlinear propagation of short wavelength drift-Alfven waves

    DEFF Research Database (Denmark)

    Shukla, P. K.; Pecseli, H. L.; Juul Rasmussen, Jens

    1986-01-01

    Making use of a kinetic ion and a hydrodynamic electron description together with the Maxwell equation, the authors derive a set of nonlinear equations which governs the dynamics of short wavelength ion drift-Alfven waves. It is shown that the nonlinear drift-Alfven waves can propagate as two-dim...

  1. Learning effect of standard automated perimetry in healthy individuals Efeito aprendizado da perimetria automática padrão em indivíduos saudáveis

    Directory of Open Access Journals (Sweden)

    Dinorah Piacentini Engel Castro

    2008-08-01

    Full Text Available PURPOSE: To evaluate the learning effect in standard automated perimetry using SITA strategy, central 24-2 program, possible associated factors and spatial distribution in individuals with no perimetry experience. METHODS: A total of 55 healthy subjects were submitted to Humphrey perimetry in two different sessions in one day. Reliability and global indices, and threshold sensitivity at each point were compared between the two examinations. The influence of potential factors (age, gender, and educational level and the spatial distribution were evaluated regarding alterations between these two examinations. RESULTS: The duration of the test was longer in the first session (median, 5.7 min; interquartile range [IQR], 1.7 min than in the second (median, 5.3; IQR, 1.1 min (p=0.002. The median (IQR of false negative errors was 2% (6% in the first examination and 0% (6% in the second (p=0.04. The mean (standard deviation in the mean deviation (MD global index was -2.31 (1.86 dB in the first examination and -1.73 (1.69 dB in the second (p=0.07. No association was observed between the change in MD and age (p=0.29, gender (p=0.69 and educational level (p=0.27. The changes in threshold sensitivity were greater at the peripheral points than at the central points (pOBJETIVO: Avaliar o efeito aprendizado da perimetria automatizada padrão com a estratégia SITA, programa central 24-2, possíveis fatores associados e distribuição espacial em indivíduos inexperientes em perimetria. MÉTODOS: Um total de 55 indivíduos saudáveis foi submetido a exame de perimetria com aparelho Humphrey em duas sessões no mesmo dia. Foram comparados os índices de confiabilidade, globais e limiares de sensibilidade de cada ponto entre os exames. Foram analisados potenciais fatores relacionados (idade, sexo e nível educacional, bem como a distribuição espacial em relação à alteração entre os exames. RESULTADOS: A duração do exame foi maior na primeira sess

  2. Optical Detection in Ultrafast Short Wavelength Science

    International Nuclear Information System (INIS)

    Fullagar, Wilfred K.; Hall, Chris J.

    2010-01-01

    A new approach to coherent detection of ionising radiation is briefly motivated and recounted. The approach involves optical scattering of coherent light fields by colour centres in transparent solids. It has significant potential for diffractive imaging applications that require high detection dynamic range from pulsed high brilliance short wavelength sources. It also motivates new incarnations of Bragg's X-ray microscope for pump-probe studies of ultrafast molecular structure-dynamics.

  3. [Follow-up on MEWDS by fundus perimetry and multifocal ERG with the SLO].

    Science.gov (United States)

    Bültmann, S; Martin, M; Rohrschneider, K

    2002-09-01

    Most conventional techniques for examination such as perimetry or ERG may not be sensitive enough to detect functional alterations due to MEWDS precisely. We report on a follow-up performed by fundus perimetry and the new technique of multifocal ERG using the scanning laser ophthalmoscope. A 24-year-old female patient (VA 0.2/0.8) was followed up for 7 weeks with these techniques as well as Octopus perimetry, fluorescence angiography, Ganzfeld ERG and biomicroscopy. Multifocal ERG stimulation (mfERG, Retiscan) was performed with the SLO. Visual acuity improved from 0.2 to 0.8 and the central relative scotoma disappeared while a relevant increase of P1-wave amplitudes in mfERG could be observed. Combining objective measurements from the fundus controlled SLO-mfERG and results from fundus perimetry enable good correlation of morphology and results, even for minor alterations of the macula only accessible by few established clinical examinations.

  4. Objective perimetry using a four-channel multifocal VEP system: correlation with conventional perimetry and thickness of the retinal nerve fibre layer.

    Science.gov (United States)

    Horn, Folkert K; Kaltwasser, Christoph; Jünemann, Anselm G; Kremers, Jan; Tornow, Ralf P

    2012-04-01

    There is evidence that multifocal visual evoked potentials (VEPs) can be used as an objective tool to detect visual field loss. The aim of this study was to correlate multifocal VEP amplitudes with standard perimetry data and retinal nerve fibre layer (RNFL) thickness. Multifocal VEP recordings were performed with a four-channel electrode array using 58 stimulus fields (pattern reversal dartboard). For each field, the recording from the channel with maximal signal-to-noise ratio (SNR) was retained, resulting in an SNR optimised virtual recording. Correlation with RNFL thickness, measured with spectral domain optical coherence tomography and with standard perimetry, was performed for nerve fibre bundle related areas. The mean amplitudes in nerve fibre related areas were smaller in glaucoma patients than in normal subjects. The differences between both groups were most significant in mid-peripheral areas. Amplitudes in these areas were significantly correlated with corresponding RNFL thickness (Spearman R=0.76) and with standard perimetry (R=0.71). The multifocal VEP amplitude was correlated with perimetric visual field data and the RNFL thickness of the corresponding regions. This method of SNR optimisation is useful for extracting data from recordings and may be appropriate for objective assessment of visual function at different locations. This study has been registered at http://www.clinicaltrials.gov (NCT00494923).

  5. Reliability of Volumetry and Perimetry to Assess Knee Volume.

    Science.gov (United States)

    Nunes, Guilherme S; Yamashitafuji, Igor; Wageck, Bruna; Teixeira, Guilherme Garcia; Karloh, Manuela; de Noronha, Marcos

    2016-08-24

    The treatment of edema after a knee injury is usually 1 of the main objectives during rehabilitation. To assess the success of treatment, 2 methods are commonly used in clinical practice: volumetry and perimetry. To investigate the intra- and interassessor reliability of volumetry and perimetry to assess knee volume. Cross-sectional. Laboratory. 45 healthy participants (26 women) with mean age of 22.4 ± 2.8 y. Knee volume was assessed by 3 assessors (A, B, and C) with 3 methods (lower-limb volumetry [LLV], knee volumetry [KV], and knee perimetry [KP]). Assessor A was the most-experienced assessor, and assessor C, the least experienced. LLV and KV were performed with participants in the orthostatic position, while KP was performed with participants in supine. For the interassessor analysis, the ICC2,1 was high (.82) for KV and very high for LLV (.99) and KP (.99). For the intra-assessor analysis, ICC2,1 ranged from moderate to high for KV (.69-.83) and was very high for LLV (.99) and KP (.97-.99). KV, LLV, and KP are reliable methods, both intra- and interassessor, to measure knee volume.

  6. Short wavelength striations on expanding plasma clouds

    International Nuclear Information System (INIS)

    Winske, D.; Gary, S.P.

    1989-01-01

    The growth and evolution of short wavelength (< ion gyroradius) flute modes on a plasma expanding across an ambient magnetic field have been actively studied in recent years, both by means of experiments in the laboratory as well as in space and through numerical simulations. We review the relevant observations and simulations results, discuss the instability mechanism and related linear theory, and describe recent work to bring experiments and theory into better agreement. 30 refs., 6 figs

  7. Mapping the Structure-Function Relationship in Glaucoma and Healthy Patients Measured with Spectralis OCT and Humphrey Perimetry

    Science.gov (United States)

    Muñoz–Negrete, Francisco J.; Oblanca, Noelia; Rebolleda, Gema

    2018-01-01

    Purpose To study the structure-function relationship in glaucoma and healthy patients assessed with Spectralis OCT and Humphrey perimetry using new statistical approaches. Materials and Methods Eighty-five eyes were prospectively selected and divided into 2 groups: glaucoma (44) and healthy patients (41). Three different statistical approaches were carried out: (1) factor analysis of the threshold sensitivities (dB) (automated perimetry) and the macular thickness (μm) (Spectralis OCT), subsequently applying Pearson's correlation to the obtained regions, (2) nonparametric regression analysis relating the values in each pair of regions that showed significant correlation, and (3) nonparametric spatial regressions using three models designed for the purpose of this study. Results In the glaucoma group, a map that relates structural and functional damage was drawn. The strongest correlation with visual fields was observed in the peripheral nasal region of both superior and inferior hemigrids (r = 0.602 and r = 0.458, resp.). The estimated functions obtained with the nonparametric regressions provided the mean sensitivity that corresponds to each given macular thickness. These functions allowed for accurate characterization of the structure-function relationship. Conclusions Both maps and point-to-point functions obtained linking structure and function damage contribute to a better understanding of this relationship and may help in the future to improve glaucoma diagnosis. PMID:29850196

  8. Structure-function correlations in glaucoma using matrix and standard automated perimetry versus time-domain and spectral-domain OCT devices.

    Science.gov (United States)

    Pinto, Luciano Moreira; Costa, Elaine Fiod; Melo, Luiz Alberto S; Gross, Paula Blasco; Sato, Eduardo Toshio; Almeida, Andrea Pereira; Maia, Andre; Paranhos, Augusto

    2014-04-10

    We examined the structure-function relationship between two perimetric tests, the frequency doubling technology (FDT) matrix and standard automated perimetry (SAP), and two optical coherence tomography (OCT) devices (time-domain and spectral-domain). This cross-sectional study included 97 eyes from 29 healthy individuals, and 68 individuals with early, moderate, or advanced primary open-angle glaucoma. The correlations between overall and sectorial parameters of retinal nerve fiber layer thickness (RNFL) measured with Stratus and Spectralis OCT, and the visual field sensitivity obtained with FDT matrix and SAP were assessed. The relationship also was evaluated using a previously described linear model. The correlation coefficients for the threshold sensitivity measured with SAP and Stratus OCT ranged from 0.44 to 0.79, and those for Spectralis OCT ranged from 0.30 to 0.75. Regarding FDT matrix, the correlation ranged from 0.40 to 0.79 with Stratus OCT and from 0.39 to 0.79 with Spectralis OCT. Stronger correlations were found in the overall measurements and the arcuate sectors for both visual fields and OCT devices. A linear relationship was observed between FDT matrix sensitivity and the OCT devices. The previously described linear model fit the data from SAP and the OCT devices well, particularly in the inferotemporal sector. The FDT matrix and SAP visual sensitivities were related strongly to the RNFL thickness measured with the Stratus and Spectralis OCT devices, particularly in the overall and arcuate sectors. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  9. Operational characteristics of the OMEGA short-wavelength laser fusion facility

    International Nuclear Information System (INIS)

    Soures, J.M.; Hutchison, R.; Jacobs, S.; McCrory, R.L.; Peck, R.; Seka, W.

    1984-01-01

    Twelve beams of the OMEGA, 24 beam direct-drive laser facility have been converted to 351-nm wavelength operation. The performance characteristics of this short-wavelength facility will be discussed. Beam-to-beam energy balance of +-2.3% and on-target energy, at 351-nm, in excess of 70 J per beam have been demonstrated. Long-term performance (>600 shots) of the system has been optimized by appropriate choice of index matching liquid, optical materials and coatings. The application of this system in direct-drive laser fusion experiments will be discussed

  10. Short-Wavelength Light Enhances Cortisol Awakening Response in Sleep-Restricted Adolescents

    Directory of Open Access Journals (Sweden)

    Mariana G. Figueiro

    2012-01-01

    Full Text Available Levels of cortisol, a hormone produced by the adrenal gland, follow a daily, 24-hour rhythm with concentrations reaching a minimum in the evening and a peak near rising time. In addition, cortisol levels exhibit a sharp peak in concentration within the first hour after waking; this is known as the cortisol awakening response (CAR. The present study is a secondary analysis of a larger study investigating the impact of short-wavelength (λmax≈470 nm light on CAR in adolescents who were sleep restricted. The study ran over the course of three overnight sessions, at least one week apart. The experimental sessions differed in terms of the light exposure scenarios experienced during the evening prior to sleeping in the laboratory and during the morning after waking from a 4.5-hour sleep opportunity. Eighteen adolescents aged 12–17 years were exposed to dim light or to 40 lux (0.401 W/m2 of 470-nm peaking light for 80 minutes after awakening. Saliva samples were collected every 20 minutes to assess CAR. Exposure to short-wavelength light in the morning significantly enhanced CAR compared to dim light. Morning exposure to short-wavelength light may be a simple, yet practical way to better prepare adolescents for an active day.

  11. Short wavelength limits of current shot noise suppression

    International Nuclear Information System (INIS)

    Nause, Ariel; Dyunin, Egor; Gover, Avraham

    2014-01-01

    Shot noise in electron beam was assumed to be one of the features beyond control of accelerator physics. Current results attained in experiments at Accelerator Test Facility in Brookhaven and Linac Coherent Light Source in Stanford suggest that the control of the shot noise in electron beam (and therefore of spontaneous radiation and Self Amplified Spontaneous Emission of Free Electron Lasers) is feasible at least in the visible range of the spectrum. Here, we present a general linear formulation for collective micro-dynamics of e-beam noise and its control. Specifically, we compare two schemes for current noise suppression: a quarter plasma wavelength drift section and a combined drift/dispersive (transverse magnetic field) section. We examine and compare their limits of applicability at short wavelengths via considerations of electron phase-spread and the related Landau damping effect

  12. Short wavelength limits of current shot noise suppression

    Energy Technology Data Exchange (ETDEWEB)

    Nause, Ariel, E-mail: arielnau@post.tau.ac.il [Faculty of Exact Sciences, Department of Physics, Tel Aviv University, Tel Aviv (Israel); Dyunin, Egor; Gover, Avraham [Faculty of Engineering, Department of Physical Electronics, Tel Aviv University, Tel Aviv (Israel)

    2014-08-15

    Shot noise in electron beam was assumed to be one of the features beyond control of accelerator physics. Current results attained in experiments at Accelerator Test Facility in Brookhaven and Linac Coherent Light Source in Stanford suggest that the control of the shot noise in electron beam (and therefore of spontaneous radiation and Self Amplified Spontaneous Emission of Free Electron Lasers) is feasible at least in the visible range of the spectrum. Here, we present a general linear formulation for collective micro-dynamics of e-beam noise and its control. Specifically, we compare two schemes for current noise suppression: a quarter plasma wavelength drift section and a combined drift/dispersive (transverse magnetic field) section. We examine and compare their limits of applicability at short wavelengths via considerations of electron phase-spread and the related Landau damping effect.

  13. Towards Patient-Tailored Perimetry: Automated Perimetry Can Be Improved by Seeding Procedures With Patient-Specific Structural Information

    Science.gov (United States)

    Denniss, Jonathan; McKendrick, Allison M.; Turpin, Andrew

    2013-01-01

    Purpose: To explore the performance of patient-specific prior information, for example, from structural imaging, in improving perimetric procedures. Methods: Computer simulation was used to determine the error distribution and presentation count for Structure–Zippy Estimation by Sequential Testing (ZEST), a Bayesian procedure with prior distribution centered on a threshold prediction from structure. Structure-ZEST (SZEST) was trialled for single locations with combinations of true and predicted thresholds between 1 to 35 dB, and compared with a standard procedure with variability similar to Swedish Interactive Thresholding Algorithm (SITA) (Full-Threshold, FT). Clinical tests of glaucomatous visual fields (n = 163, median mean deviation −1.8 dB, 90% range +2.1 to −22.6 dB) were also compared between techniques. Results: For single locations, SZEST typically outperformed FT when structural predictions were within ± 9 dB of true sensitivity, depending on response errors. In damaged locations, mean absolute error was 0.5 to 1.8 dB lower, SD of threshold estimates was 1.2 to 1.5 dB lower, and 2 to 4 (29%–41%) fewer presentations were made for SZEST. Gains were smaller across whole visual fields (SZEST, mean absolute error: 0.5 to 1.2 dB lower, threshold estimate SD: 0.3 to 0.8 dB lower, 1 [17%] fewer presentation). The 90% retest limits of SZEST were median 1 to 3 dB narrower and more consistent (interquartile range 2–8 dB narrower) across the dynamic range than those for FT. Conclusion: Seeding Bayesian perimetric procedures with structural measurements can reduce test variability of perimetry in glaucoma, despite imprecise structural predictions of threshold. Translational Relevance: Structural data can reduce the variability of current perimetric techniques. A strong structure–function relationship is not necessary, however, structure must predict function within ±9 dB for gains to be realized. PMID:24049720

  14. Assessment of the reliability of standard automated perimetry in regions of glaucomatous damage.

    Science.gov (United States)

    Gardiner, Stuart K; Swanson, William H; Goren, Deborah; Mansberger, Steven L; Demirel, Shaban

    2014-07-01

    Visual field testing uses high-contrast stimuli in areas of severe visual field loss. However, retinal ganglion cells saturate with high-contrast stimuli, suggesting that the probability of detecting perimetric stimuli may not increase indefinitely as contrast increases. Driven by this concept, this study examines the lower limit of perimetric sensitivity for reliable testing by standard automated perimetry. Evaluation of a diagnostic test. A total of 34 participants with moderate to severe glaucoma; mean deviation at their last clinic visit averaged -10.90 dB (range, -20.94 to -3.38 dB). A total of 75 of the 136 locations tested had a perimetric sensitivity of ≤ 19 dB. Frequency-of-seeing curves were constructed at 4 nonadjacent visual field locations by the Method of Constant Stimuli (MOCS), using 35 stimulus presentations at each of 7 contrasts. Locations were chosen a priori and included at least 2 with glaucomatous damage but a sensitivity of ≥ 6 dB. Cumulative Gaussian curves were fit to the data, first assuming a 5% false-negative rate and subsequently allowing the asymptotic maximum response probability to be a free parameter. The strength of the relation (R(2)) between perimetric sensitivity (mean of last 2 clinic visits) and MOCS sensitivity (from the experiment) for all locations with perimetric sensitivity within ± 4 dB of each selected value, at 0.5 dB intervals. Bins centered at sensitivities ≥ 19 dB always had R(2) >0.1. All bins centered at sensitivities ≤ 15 dB had R(2) <0.1, an indication that sensitivities are unreliable. No consistent conclusions could be drawn between 15 and 19 dB. At 57 of the 81 locations with perimetric sensitivity <19 dB, including 49 of the 63 locations ≤ 15 dB, the fitted asymptotic maximum response probability was <80%, consistent with the hypothesis of response saturation. At 29 of these locations the asymptotic maximum was <50%, and so contrast sensitivity (50% response rate) is undefined. Clinical

  15. Sexual dimorphism of short-wavelength photoreceptors in the small white butterfly, Pieris rapae crucivora

    NARCIS (Netherlands)

    Arikawa, K; Wakakuwa, M; Qiu, XD; Kurasawa, M; Stavenga, DG; Qiu, Xudong

    2005-01-01

    The eyes of the female small white butterfly, Pieris rapae crucivora, are furnished with three classes of short-wavelength photoreceptors, with sensitivity peaks in the ultraviolet (UV) (lambda(max) = 360 nm), violet (V) (lambda max = 425 nm), and blue (B) (lambda(max) = 453 nm) wavelength range.

  16. Lack of short-wavelength light during the school day delays dim light melatonin onset (DLMO) in middle school students.

    Science.gov (United States)

    Figueiro, Mariana G; Rea, Mark S

    2010-01-01

    Circadian timing affects sleep onset. Delayed sleep onset can reduce sleep duration in adolescents required to awake early for a fixed school schedule. The absence of short-wavelength ("blue") morning light, which helps entrain the circadian system, can hypothetically delay sleep onset and decrease sleep duration in adolescents. The goal of this study was to investigate whether removal of short-wavelength light during the morning hours delayed the onset of melatonin in young adults. Dim light melatonin onset (DLMO) was measured in eleven 8th-grade students before and after wearing orange glasses, which removed short-wavelength light, for a five-day school week. DLMO was significantly delayed (30 minutes) after the five-day intervention, demonstrating that short-wavelength light exposure during the day can be important for advancing circadian rhythms in students. Lack of short-wavelength light in the morning has been shown to delay the circadian clock in controlled laboratory conditions. The results presented here are the first to show, outside laboratory conditions, that removal of short-wavelength light in the morning hours can delay DLMO in 8th-grade students. These field data, consistent with results from controlled laboratory studies, are directly relevant to lighting practice in schools.

  17. Short wavelength laser-plasma interaction experiments in a spherical geometry

    International Nuclear Information System (INIS)

    Keck, R.L.

    1984-01-01

    Short wavelength (250 to 500 nm) lasers should provide reduced fast electron preheat and increased laser-pellet coupling efficiency when used as laser fusion drivers. As part of an ongoing effort to study short wavelength laser plasm interaction, six beams of the 24 beam OMEGA Nd-glass laser system have been converted to operation at the third harmonic. This system is capable of providing in excess of 250 Joules of 351 nm light on spherical targets at intensities up to 2 x 10/sup 15/ W/cm/sup 2/. To date, experiments have been performed to study the uniformity of irradiation, laser absorption, fast electron production and preheat, energy transport within the target and underdense plasma instabilities. Both x-ray continuum measurements and Kα line measurements indicate that the absorption is dominated by inverse bremsstrahlung. Electron energy transport has been studied using x-ray burn-through and charge collector measurements. The results show that with 351 nm irradiation ablation pressures of order 100 Mbars are generated at intensities of 10/sup 15/ W/cm/sup 2/

  18. Short-wavelength free-electron laser sources and science: a review

    Science.gov (United States)

    Seddon, E. A.; Clarke, J. A.; Dunning, D. J.; Masciovecchio, C.; Milne, C. J.; Parmigiani, F.; Rugg, D.; Spence, J. C. H.; Thompson, N. R.; Ueda, K.; Vinko, S. M.; Wark, J. S.; Wurth, W.

    2017-11-01

    This review is focused on free-electron lasers (FELs) in the hard to soft x-ray regime. The aim is to provide newcomers to the area with insights into: the basic physics of FELs, the qualities of the radiation they produce, the challenges of transmitting that radiation to end users and the diversity of current scientific applications. Initial consideration is given to FEL theory in order to provide the foundation for discussion of FEL output properties and the technical challenges of short-wavelength FELs. This is followed by an overview of existing x-ray FEL facilities, future facilities and FEL frontiers. To provide a context for information in the above sections, a detailed comparison of the photon pulse characteristics of FEL sources with those of other sources of high brightness x-rays is made. A brief summary of FEL beamline design and photon diagnostics then precedes an overview of FEL scientific applications. Recent highlights are covered in sections on structural biology, atomic and molecular physics, photochemistry, non-linear spectroscopy, shock physics, solid density plasmas. A short industrial perspective is also included to emphasise potential in this area. Dedicated to John M J Madey (1943-2016) and Rodolfo Bonifacio (1940-2016) whose perception, drive and perseverance paved the way for the realisation and development of short-wavelength free-electron lasers.

  19. Influence of wavelength on transient short-circuit current in polycrystalline silicon solar cells

    International Nuclear Information System (INIS)

    Ba, B.; Kane, M.

    1993-10-01

    The influence of the wavelength of a monochromatic illumination on transient short-circuit current in an n/p polycrystalline silicon part solar cell junction is investigated. A wavelength dependence in the initial part of the current decay is observed in the case of cells with moderate grain boundary effects. This influence is attenuated in polycrystalline cells with strong grain boundary activity. (author). 10 refs, 6 figs

  20. Short-wavelength attenuated polychromatic white light during work at night : Limited melatonin suppression without substantial decline of alertness

    NARCIS (Netherlands)

    van de Werken, Maan; Giménez, Marina C; de Vries, Bonnie; Beersma, Domien G M; Gordijn, Marijke C M

    Exposure to light at night increases alertness, but light at night (especially short-wavelength light) also disrupts nocturnal physiology. Such disruption is thought to underlie medical problems for which shiftworkers have increased risk. In 33 male subjects we investigated whether short-wavelength

  1. Study of Optimal Perimetric Testing in Children (OPTIC: Feasibility, Reliability and Repeatability of Perimetry in Children.

    Directory of Open Access Journals (Sweden)

    Dipesh E Patel

    Full Text Available To investigate feasibility, reliability and repeatability of perimetry in children.A prospective, observational study recruiting 154 children aged 5-15 years, without an ophthalmic condition that affects the visual field (controls, identified consecutively between May 2012 and November 2013 from hospital eye clinics. Perimetry was undertaken in a single sitting, with standardised protocols, in a randomised order using the Humphrey static (SITA 24-2 FAST, Goldmann and Octopus kinetic perimeters. Data collected included test duration, subjective experience and test quality (incorporating examiner ratings on comprehension of instructions, fatigue, response to visual and auditory stimuli, concentration and co-operation to assess feasibility and reliability. Testing was repeated within 6 months to assess repeatability.Overall feasibility was very high (Goldmann=96.1%, Octopus=89% and Humphrey=100% completed the tests. Examiner rated reliability was 'good' in 125 (81.2% children for Goldmann, 100 (64.9% for Octopus and 98 (63.6% for Humphrey perimetry. Goldmann perimetry was the most reliable method in children under 9 years of age. Reliability improved with increasing age (multinomial logistic regression (Goldmann, Octopus and Humphrey, p<0.001. No significant differences were found for any of the three test strategies when examining initial and follow-up data outputs (Bland-Altman plots, n=43, suggesting good test repeatability, although the sample size may preclude detection of a small learning effect.Feasibility and reliability of formal perimetry in children improves with age. By the age of 9 years, all the strategies used here were highly feasible and reliable. Clinical assessment of the visual field is achievable in children as young as 5 years, and should be considered where visual field loss is suspected. Since Goldmann perimetry is the most effective strategy in children aged 5-8 years and this perimeter is no longer available, further

  2. Multifocal Visual Evoked Potential in Eyes With Temporal Hemianopia From Chiasmal Compression: Correlation With Standard Automated Perimetry and OCT Findings.

    Science.gov (United States)

    Sousa, Rafael M; Oyamada, Maria K; Cunha, Leonardo P; Monteiro, Mário L R

    2017-09-01

    To verify whether multifocal visual evoked potential (mfVEP) can differentiate eyes with temporal hemianopia due to chiasmal compression from healthy controls. To assess the relationship between mfVEP, standard automated perimetry (SAP), and Fourier domain-optical coherence tomography (FD-OCT) macular and peripapillary retinal nerve fiber layer (RNFL) thickness measurements. Twenty-seven eyes with permanent temporal visual field (VF) defects from chiasmal compression on SAP and 43 eyes of healthy controls were submitted to mfVEP and FD-OCT scanning. Multifocal visual evoked potential was elicited using a stimulus pattern of 60 sectors and the responses were averaged for the four quadrants and two hemifields. Optical coherence tomography macular measurements were averaged in quadrants and halves, while peripapillary RNFL thickness was averaged in four sectors around the disc. Visual field loss was estimated in four quadrants and each half of the 24-2 strategy test points. Multifocal visual evoked potential measurements in the two groups were compared using generalized estimated equations, and the correlations between mfVEP, VF, and OCT findings were quantified. Multifocal visual evoked potential-measured temporal P1 and N2 amplitudes were significantly smaller in patients than in controls. No significant difference in amplitude was observed for nasal parameters. A significant correlation was found between mfVEP amplitudes and temporal VF loss, and between mfVEP amplitudes and the corresponding OCT-measured macular and RNFL thickness parameters. Multifocal visual evoked potential amplitude parameters were able to differentiate eyes with temporal hemianopia from controls and were significantly correlated with VF and OCT findings, suggesting mfVEP is a useful tool for the detection of visual abnormalities in patients with chiasmal compression.

  3. Observation of magnon-phonon interaction at short wavelengths

    International Nuclear Information System (INIS)

    Dolling, G.; Cowley, R.A.

    1966-01-01

    Measurements have been made of the magnon and phonon dispersion relations in uranium dioxide at 9 o K. These measurements provide evidence of a strong interaction between the magnon and phonon excitations and enable a value to be deduced for the coupling constant. The interaction of long-wavelength magnons in ferromagnetic materials has been studied previously with ultrasonic techniques; however, inelastic scattering of slow neutrons enables both the magnon and phonon dispersion relations to be determined for short wavelengths. In those magnetic materials which have been studied by earlier workers, the magnons and phonons either interacted with one another very weakly or else their frequencies were very different. The results could then be understood without introducing any magnon-phonon interaction. In this note we report measurements of both the magnon and the phonon spectra of antiferromagnetic uranium dioxide, which lead to a magnon-phonon coupling constant of 9.6 ± 1.6 o K. Since the Neel temperature is 30.8 o K, this coupling constant is of a similar magnitude to the direct magnetic interactions. (author)

  4. Short-wavelength magnetic recording new methods and analyses

    CERN Document Server

    Ruigrok, JJM

    2013-01-01

    Short-wavelength magnetic recording presents a series of practical solutions to a wide range of problems in the field of magnetic recording. It features many new and original results, all derived from fundamental principles as a result of up-to-date research.A special section is devoted to the playback process, including the calculations of head efficiency and head impedance, derived from new theorems.Features include:A simple and fast method for measuring efficiency; a simple method for the accurate separation of the read and write behaviour of magnetic heads; a new concept - the bandpass hea

  5. Scanning laser densitometry and color perimetry demonstrate reduced photopigment density and sensitivity in two patients with retinal degeneration.

    Science.gov (United States)

    Tornow, R P; Stilling, R; Zrenner, E

    1999-10-01

    To test the feasibility of scanning laser densitometry with a modified Rodenstock scanning laser ophthalmoscope (SLO) to measure the rod and cone photopigment distribution in patients with retinal diseases. Scanning laser densitometry was performed using a modified Rodenstock scanning laser ophthalmoscope. The distribution of the photopigments was calculated from dark adapted and bleached images taken with the 514 nm laser of the SLO. This wavelength is absorbed by rod and cone photopigments. Discrimination is possible due to their different spatial distribution. Additionally, to measure retinal sensitivity profiles, dark adapted two color static perimetry with a Tübinger manual perimeter was performed along the horizontal meridian with 1 degree spacing. A patient with retinitis pigmentosa had slightly reduced photopigment density within the central +/- 5 degrees but no detectable photopigment for eccentricities beyond 5 degrees. A patient with cone dystrophy had nearly normal pigment density beyond +/- 5 degrees, but considerably reduced photopigment density within the central +/- 5 degrees. Within the central +/- 5 degrees, the patient with retinitis pigmentosa had normal sensitivity for the red stimulus and reduced sensitivity for the green stimulus. There was no measurable function beyond 7 degrees. The patient with cone dystrophy had normal sensitivity for the green stimulus outside the foveal center and reduced sensitivity for the red stimulus at the foveal center. The results of color perimetry for this patient with a central scotoma were probably influenced by eccentric fixation. Scanning laser densitometry with a modified Rodenstock SLO is a useful method to assess the human photopigment distribution. Densitometry results were confirmed by dark adapted two color static perimetry. Photopigment distribution and retinal sensitivity profiles can be measured with high spatial resolution. This may help to measure exactly the temporal development of retinal

  6. Extended short wavelength infrared HgCdTe detectors on silicon substrates

    Science.gov (United States)

    Park, J. H.; Hansel, D.; Mukhortova, A.; Chang, Y.; Kodama, R.; Zhao, J.; Velicu, S.; Aqariden, F.

    2016-09-01

    We report high-quality n-type extended short wavelength infrared (eSWIR) HgCdTe (cutoff wavelength 2.59 μm at 77 K) layers grown on three-inch diameter CdTe/Si substrates by molecular beam epitaxy (MBE). This material is used to fabricate test diodes and arrays with a planar device architecture using arsenic implantation to achieve p-type doping. We use different variations of a test structure with a guarded design to compensate for the lateral leakage current of traditional test diodes. These test diodes with guarded arrays characterize the electrical performance of the active 640 × 512 format, 15 μm pitch detector array.

  7. Stability of short wavelength tearing and twisting modes

    International Nuclear Information System (INIS)

    Waelbroeck, F.L.

    1998-01-01

    The stability and mutual interaction of tearing and twisting modes in a torus is governed by matrices that generalize the well-known Δ' stability index. The diagonal elements of these matrices determine the intrinsic stability of modes that reconnect the magnetic field at a single resonant surface. The off-diagonal elements indicate the strength of the coupling between the different modes. The author shows how the elements of these matrices can be evaluated, in the limit of short wavelength, from the free energy driving radially extended ballooning modes. The author applies the results by calculating the tearing and twisting Δ' for a model high-beta equilibrium with circular flux surfaces

  8. Sequentially optimized reconstruction strategy: A meta-strategy for perimetry testing.

    Directory of Open Access Journals (Sweden)

    Şerife Seda Kucur

    Full Text Available Perimetry testing is an automated method to measure visual function and is heavily used for diagnosing ophthalmic and neurological conditions. Its working principle is to sequentially query a subject about perceived light using different brightness levels at different visual field locations. At a given location, this query-patient-feedback process is expected to converge at a perceived sensitivity, such that a shown stimulus intensity is observed and reported 50% of the time. Given this inherently time-intensive and noisy process, fast testing strategies are necessary in order to measure existing regions more effectively and reliably. In this work, we present a novel meta-strategy which relies on the correlative nature of visual field locations in order to strongly reduce the necessary number of locations that need to be examined. To do this, we sequentially determine locations that most effectively reduce visual field estimation errors in an initial training phase. We then exploit these locations at examination time and show that our approach can easily be combined with existing perceived sensitivity estimation schemes to speed up the examinations. Compared to state-of-the-art strategies, our approach shows marked performance gains with a better accuracy-speed trade-off regime for both mixed and sub-populations.

  9. Local instabilities in magnetized rotational flows: A short-wavelength approach

    OpenAIRE

    Kirillov, Oleg N.; Stefani, Frank; Fukumoto, Yasuhide

    2014-01-01

    We perform a local stability analysis of rotational flows in the presence of a constant vertical magnetic field and an azimuthal magnetic field with a general radial dependence. Employing the short-wavelength approximation we develop a unified framework for the investigation of the standard, the helical, and the azimuthal version of the magnetorotational instability, as well as of current-driven kink-type instabilities. Considering the viscous and resistive setup, our main focus is on the cas...

  10. Experimental tests of induced spatial incoherence using short laser wavelength

    International Nuclear Information System (INIS)

    Obenschain, S.P.; Grun, J.; Herbst, M.J.

    1986-01-01

    The authors have developed a laser beam smoothing technique called induced spatial incoherence (ISI), which can produce the highly uniform focal profiles required for direct-drive laser fusion. Uniform well-controlled focal profiles are required to obtain the highly symmetric pellet implosions needed for high-energy gain. In recent experiments, the authors' tested the effects of ISI on high-power laser-target interaction. With short laser wavelength, the coupling physics dramatically improved over that obtained with an ordinary laser beam

  11. Influence of test reliability on the screening performance of frequency-doubling perimetry

    NARCIS (Netherlands)

    Heeg, GP; Jansonius, NM

    PURPOSE: To investigate the influence of test reliability on the screening performance of frequency,doubling perimetry (FDT). DESIGN: Cross-sectional study. METHODS: FDT sensitivity and specificity were calculated three times using three different strategies for handling unreliable (that is, > 0

  12. Self Referencing Heterodyne Transient Grating Spectroscopy with Short Wavelength

    Directory of Open Access Journals (Sweden)

    Jakob Grilj

    2015-04-01

    Full Text Available Heterodyning by a phase stable reference electric field is a well known technique to amplify weak nonlinear signals. For short wavelength, the generation of a reference field in front of the sample is challenging because of a lack of suitable beamsplitters. Here, we use a permanent grating which matches the line spacing of the transient grating for the creation of a phase stable reference field. The relative phase among the two can be changed by a relative translation of the permanent and transient gratings in direction orthogonal to the grating lines. We demonstrate the technique for a transient grating on a VO2 thin film and observe constructive as well as destructive interference signals.

  13. A cure for the blues: opsin duplication and subfunctionalization for short-wavelength sensitivity in jewel beetles (Coleoptera: Buprestidae).

    Science.gov (United States)

    Lord, Nathan P; Plimpton, Rebecca L; Sharkey, Camilla R; Suvorov, Anton; Lelito, Jonathan P; Willardson, Barry M; Bybee, Seth M

    2016-05-18

    Arthropods have received much attention as a model for studying opsin evolution in invertebrates. Yet, relatively few studies have investigated the diversity of opsin proteins that underlie spectral sensitivity of the visual pigments within the diverse beetles (Insecta: Coleoptera). Previous work has demonstrated that beetles appear to lack the short-wavelength-sensitive (SWS) opsin class that typically confers sensitivity to the "blue" region of the light spectrum. However, this is contrary to established physiological data in a number of Coleoptera. To explore potential adaptations at the molecular level that may compensate for the loss of the SWS opsin, we carried out an exploration of the opsin proteins within a group of beetles (Buprestidae) where short-wave sensitivity has been demonstrated. RNA-seq data were generated to identify opsin proteins from nine taxa comprising six buprestid species (including three male/female pairs) across four subfamilies. Structural analyses of recovered opsins were conducted and compared to opsin sequences in other insects across the main opsin classes-ultraviolet, short-wavelength, and long-wavelength. All nine buprestids were found to express two opsin copies in each of the ultraviolet and long-wavelength classes, contrary to the single copies recovered in all other molecular studies of adult beetle opsin expression. No SWS opsin class was recovered. Furthermore, the male Agrilus planipennis (emerald ash borer-EAB) expressed a third LWS opsin at low levels that is presumed to be a larval copy. Subsequent homology and structural analyses identified multiple amino acid substitutions in the UVS and LWS copies that could confer short-wavelength sensitivity. This work is the first to compare expressed opsin genes against known electrophysiological data that demonstrate multiple peak sensitivities in Coleoptera. We report the first instance of opsin duplication in adult beetles, which occurs in both the UVS and LWS opsin classes

  14. Effect of aspherical and yellow tinted intraocular lens on blue-on-yellow perimetry

    Directory of Open Access Journals (Sweden)

    Rodrigo França de Espíndola

    2012-10-01

    Full Text Available PURPOSE: To investigate the possible effect of aspherical or yellow tinted intraocular lens (IOL on contrast sensitivity and blue-on-yellow perimetry. METHODS: This prospective randomized bilateral double-masked clinical study included 52 patients with visually significant bilateral cataracts divided in two groups; 25 patients (50 eyes received aspherical intraocular lens in one eye and spherical intraocular lens in the fellow eye; and 27 patients (54 eyes received ultraviolet and blue light filter (yellow tinted IOL implantation in one eye and acrylic ultraviolet filter IOL in the fellow eye. The primary outcome measures were contrast sensitivity and blue-on-yellow perimetry values (mean deviation [MD] and pattern standard deviation [PSD] investigated two years after surgery. The results were compared intra-individually. RESULTS: There was a statistically significant between-group (aspherical and spherical intraocular lens difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. There were no between-group significant differences (yellow tinted and clear intraocular lens under photopic or mesopic conditions. There was no statistically significant difference between all intraocular lens in MD or PSD. CONCLUSION: Contrast sensitivity was better under mesopic conditions with aspherical intraocular lens. Blue-on-yellow perimetry did not appear to be affected by aspherical or yellow tinted intraocular lens. Further studies with a larger sample should be carried out to confirm or not that hypotheses.

  15. Laser spectroscopy on atoms and ions using short-wavelength radiation

    International Nuclear Information System (INIS)

    Larsson, Joergen.

    1994-05-01

    Radiative properties and energy structures in atoms and ions have been investigated using UV/VUV radiation. In order to obtain radiation at short wavelengths, frequency mixing of pulsed laser radiation in crystals and gases has been performed using recently developed frequency-mixing schemes. To allow the study of radiative lifetimes shorter than the pulses from standard Q-switched lasers, different techniques have been used to obtain sufficiently short pulses. The Hanle effect has been employed following pulsed laser excitation for the same purpose. High-resolution spectroscopic techniques have been adapted for use with the broad-band, pulsed laser sources which are readily available in the UV/VUV spectral region. In order to investigate sources of radiation in the XUV and soft X-ray spectral regions, harmonic generation in rare gases has been studied. The generation of coherent radiation by the interaction between laser radiation and relativistic electrons in a synchrotron storage ring has also been investigated. 60 refs

  16. Modelling single shot damage thresholds of multilayer optics for high-intensity short-wavelength radiation sources

    NARCIS (Netherlands)

    Loch, R.A.; Sobierajski, R.; Louis, Eric; Bosgra, J.; Bosgra, J.; Bijkerk, Frederik

    2012-01-01

    The single shot damage thresholds of multilayer optics for highintensity short-wavelength radiation sources are theoretically investigated, using a model developed on the basis of experimental data obtained at the FLASH and LCLS free electron lasers. We compare the radiation hardness of commonly

  17. Short-Wavelength Infrared (SWIR) spectroscopy of low-grade metamorphic volcanic rocks of the Pilbara Craton

    NARCIS (Netherlands)

    Abweny, Mohammad S.; van Ruitenbeek, Frank J A; de Smeth, Boudewijn; Woldai, Tsehaie; van der Meer, Freek D.; Cudahy, Thomas; Zegers, Tanja; Blom, Jan Kees; Thuss, Barbara

    This paper shows the results of Short-Wavelength Infrared (SWIR) spectroscopy investigations of volcanic rocks sampled from low-grade metamorphic greenstone belts of the Archean Pilbara Craton in Western Australia. From the reflectance spectra a range of spectrally active minerals were identified,

  18. Backscattering of gyrotron radiation and short-wavelength turbulence during electron cyclotron resonance plasma heating in the L-2M stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Batanov, G. M.; Borzosekov, V. D., E-mail: tinborz@gmail.com; Kovrizhnykh, L. M.; Kolik, L. V.; Konchekov, E. M.; Malakhov, D. V.; Petrov, A. E.; Sarksyan, K. A.; Skvortsova, N. N.; Stepakhin, V. D.; Kharchev, N. K. [Russian Academy of Sciences, Prokhorov General Physics Institute (Russian Federation)

    2013-06-15

    Backscattering of gyrotron radiation ({theta} = {pi}) by short-wavelength density fluctuations (k{sub Up-Tack} = 30 cm{sup -1}) in the plasma of the L-2M stellarator was studied under conditions of electron cyclotron resonance (ECR) plasma heating at the second harmonic of the electron gyrofrequency (75 GHz). The scattering of the O-wave emerging due to the splitting of the linearly polarized gyrotron radiation into the X- and O-waves was analyzed. The signal obtained after homodyne detection of scattered radiation is a result of interference of the reference signal, the quasi-steady component, and the fast oscillating component. The coefficients of reflection of the quasi-steady component, R{sub =}{sup 2}(Y), and fast oscillating component, R{sub {approx}}{sup 2}(Y), of scattered radiation are estimated. The growth of the R{sub {approx}}{sup 2}(Y) coefficient from 3.7 Multiplication-Sign 10{sup -4} to 5.2 Multiplication-Sign 10{sup -4} with increasing ECR heating power from 190 to 430 kW is found to correlate with the decrease in the energy lifetime from 1.9 to 1.46 ms. The relative density of short-wavelength fluctuations is estimated to be Left-Pointing-Angle-Bracket n{sub {approx}}{sup 2} Right-Pointing-Angle-Bracket / Left-Pointing-Angle-Bracket n{sub e}{sup 2} Right-Pointing-Angle-Bracket = 3 Multiplication-Sign 10{sup -7}. It is shown that the frequencies of short-wavelength fluctuations are in the range 10-150 kHz. The recorded short-wavelength fluctuations can be interpreted as structural turbulence, the energy of which comprises {approx}10% of the total fluctuations energy. Simulations of transport processes show that neoclassical heat fluxes are much smaller than anomalous ones. It is suggested that short-wavelength turbulence plays a decisive role in the anomalous heat transport.

  19. Automated Analysis of Short Responses in an Interactive Synthetic Tutoring System for Introductory Physics

    Science.gov (United States)

    Nakamura, Christopher M.; Murphy, Sytil K.; Christel, Michael G.; Stevens, Scott M.; Zollman, Dean A.

    2016-01-01

    Computer-automated assessment of students' text responses to short-answer questions represents an important enabling technology for online learning environments. We have investigated the use of machine learning to train computer models capable of automatically classifying short-answer responses and assessed the results. Our investigations are part…

  20. Nonlinear-optical generation of short-wavelength radiation controlled by laser-induced interference structures

    International Nuclear Information System (INIS)

    Popov, A K; Kimberg, V V

    1998-01-01

    A study is reported of the combined influence of laser-induced resonances in the energy continuum, of splitting of discrete resonances in the field of several strong radiations, and of absorption of the initial and generated radiations on totally resonant parametric conversion to the short-wavelength range. It is shown that the radiation power can be increased considerably by interference processes involving quantum transitions. (nonlinear optical phenomena and devices)

  1. Evidence for nonuniversal behavior of paraconductivity caused by predominant short-wavelength Gaussian fluctuations in YBa2Cu3O6.9

    International Nuclear Information System (INIS)

    Gauzzi, A.; Pavuna, D.

    1995-01-01

    We report on in-plane paraconductivity measurements in thin YBa 2 Cu 3 O 6.9 films. Our analysis of the data shows that the temperature dependence of paraconductivity is affected by lattice disorder and deviates at all temperatures from the universal power laws predicted by both scaling and mean-field theories. This gives evidence for the absence of critical fluctuations and for the failure of the Aslamazov-Larkin universal relation between critical exponent and dimensionality of the spectrum of Gaussian fluctuations. We account quantitatively for the data within the experimental error by introducing a short-wavelength cutoff into this spectrum. This implies that three-dimensional short-wavelength Gaussian fluctuations dominate in YBa 2 Cu 3 O 6.9 and suggests a rapid attenuation of these fluctuations with decreasing wavelength in short-coherence-length systems as compared to the case of the conventional Ginzburg-Landau theory

  2. The opto-cryo-mechanical design of the short wavelength camera for the CCAT Observatory

    Science.gov (United States)

    Parshley, Stephen C.; Adams, Joseph; Nikola, Thomas; Stacey, Gordon J.

    2014-07-01

    The CCAT observatory is a 25-m class Gregorian telescope designed for submillimeter observations that will be deployed at Cerro Chajnantor (~5600 m) in the high Atacama Desert region of Chile. The Short Wavelength Camera (SWCam) for CCAT is an integral part of the observatory, enabling the study of star formation at high and low redshifts. SWCam will be a facility instrument, available at first light and operating in the telluric windows at wavelengths of 350, 450, and 850 μm. In order to trace the large curvature of the CCAT focal plane, and to suit the available instrument space, SWCam is divided into seven sub-cameras, each configured to a particular telluric window. A fully refractive optical design in each sub-camera will produce diffraction-limited images. The material of choice for the optical elements is silicon, due to its excellent transmission in the submillimeter and its high index of refraction, enabling thin lenses of a given power. The cryostat's vacuum windows double as the sub-cameras' field lenses and are ~30 cm in diameter. The other lenses are mounted at 4 K. The sub-cameras will share a single cryostat providing thermal intercepts at 80, 15, 4, 1 and 0.1 K, with cooling provided by pulse tube cryocoolers and a dilution refrigerator. The use of the intermediate temperature stage at 15 K minimizes the load at 4 K and reduces operating costs. We discuss our design requirements, specifications, key elements and expected performance of the optical, thermal and mechanical design for the short wavelength camera for CCAT.

  3. Computer-Automated Approach for Scoring Short Essays in an Introductory Statistics Course

    Science.gov (United States)

    Zimmerman, Whitney Alicia; Kang, Hyun Bin; Kim, Kyung; Gao, Mengzhao; Johnson, Glenn; Clariana, Roy; Zhang, Fan

    2018-01-01

    Over two semesters short essay prompts were developed for use with the Graphical Interface for Knowledge Structure (GIKS), an automated essay scoring system. Participants were students in an undergraduate-level online introductory statistics course. The GIKS compares students' writing samples with an expert's to produce keyword occurrence and…

  4. Gamma-ray detection with an UV-enhanced photodiode and scintillation crystals emitting at short wavelengths

    International Nuclear Information System (INIS)

    Johansen, G.A.

    1997-01-01

    A low-noise ion implanted photodiode with high spectral response in the deep blue/UV region has been tested as read-out device for scintillation crystals with matching emission spectra (YAP(Ce), GSO(Ce), BGO and CsI(Tl)). This gamma-ray detector concept is attractive in many industrial applications where compactness, reliability and ambient temperature operation are important. The results show that the amount of detected scintillation light energy falls rapidly off as the wavelength of the scintillation light decreases. It is concluded that the dynamic spectral response of the photodiode, due to increasing carrier collection times, is considerably less than the DC response at short wavelengths. The diode is not useful in pulse mode operation with scintillation crystals emitting at wavelengths below about 400 nm. For read-out of CsI(Tl) with 661.6 keV gamma-radiation, however, the photodiode concept shows better energy resolution (7.1%) than other detectors. (orig.)

  5. Beam dynamics simulations for linacs driving short-wavelength FELs

    International Nuclear Information System (INIS)

    Ferrario, M.; Tazzioli, F.

    1999-01-01

    The fast code HOMDYN has been recently developed, in the framework of the TTF (Tesla test facility) collaboration, in order to study the beam dynamics of linacs delivering high brightness beams as those needed for short wavelength Fel experiments. These linacs are typically driven by radio-frequency photo-injectors, where correlated time dependent space charge effects are of great relevance: these effects cannot be studied by standard beam optics codes (TRACE3D, etc.) and they have been modeled so far by means of multi-particle (Pic or quasistatic) codes requiring heavy cpu time and memory allocations. HOMDYN is able to describe the beam generation at the photo-cathode and the emittance compensation process in the injector even running on a laptop with very modest running rimes (less than a minute). In this paper it is showed how this capability of the code is exploited so to model a whole linac up to the point where the space charge dominated regime is of relevance (200 MeV)

  6. Short wavelength light filtering by the natural human lens and IOLs -- implications for entrainment of circadian rhythm

    DEFF Research Database (Denmark)

    Brøndsted, Adam Elias; Lundeman, Jesper Holm; Kessel, Line

    2013-01-01

    Photoentrainment of circadian rhythm begins with the stimulation of melanopsin containing retinal ganglion cells that respond directly to blue light. With age, the human lens becomes a strong colour filter attenuating transmission of short wavelengths. The purpose of the study was to examine the ...

  7. Diagnostic capability of Pulsar perimetry in pre-perimetric and early glaucoma.

    Science.gov (United States)

    Hirasawa, Kazunori; Takahashi, Natsumi; Matsumura, Kazuhiro; Kasahara, Masayuki; Shoji, Nobuyuki

    2017-06-12

    This study aimed to compare the diagnostic capability of Pulsar perimetry (Pulsar) in pre-perimetric glaucoma (PPG) and early glaucoma (EG) with that of Flicker perimetry (Flicker) and spectral-domain optical conference tomography (SD-OCT). This prospective cross-sectional study included 25 eyes of 25 PPG patients, 35 eyes of 35 EG patients, and 42 eyes of 42 healthy participants. The diagnostic capability using the area under the curve (AUC) of the best parameter and agreement of detectability between structural and functional measurements were compared. For PPG patients, the AUC of Pulsar, Flicker, OCT-disc, and OCT-macular was 0.733, 0.663, 0.842, and 0.780, respectively. The AUC of Flicker was significantly lower than that of OCT-disc (p = 0.016). For EG patients, the AUC of Pulsar, Flicker, OCT-disc, and OCT-macular were 0.851, 0.869, 0.907, and 0.861, respectively. There was no significant difference in AUC among these methods. The agreement between structural and functional measurements expressed by kappa value ranged from -0.16 to 0.07 for PPG and from 0.01 to 0.25 for EG. Although the diagnostic capability of Pulsar in the PPG and EG groups was equal to that of Flicker and SD-OCT, the agreements between structural and functional measurements for both PPG and EG were poor.

  8. Integral equation based stability analysis of short wavelength drift modes in tokamaks

    International Nuclear Information System (INIS)

    Hirose, A.; Elia, M.

    2003-01-01

    Linear stability of electron skin-size drift modes in collisionless tokamak discharges has been investigated in terms of electromagnetic, kinetic integral equations in which neither ions nor electrons are assumed to be adiabatic. A slab-like ion temperature gradient mode persists in such a short wavelength regime. However, toroidicity has a strong stabilizing influence on this mode. In the electron branch, the toroidicity induced skin-size drift mode previously predicted in terms of local kinetic analysis has been recovered. The mode is driven by positive magnetic shear and strongly stabilized for negative shear. The corresponding mixing length anomalous thermal diffusivity exhibits favourable isotope dependence. (author)

  9. Development and operation of a high-throughput accurate-wavelength lens-based spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Bell, Ronald E., E-mail: rbell@pppl.gov [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States)

    2014-11-15

    A high-throughput spectrometer for the 400–820 nm wavelength range has been developed for charge exchange recombination spectroscopy or general spectroscopy. A large 2160 mm{sup −1} grating is matched with fast f/1.8 200 mm lenses, which provide stigmatic imaging. A precision optical encoder measures the grating angle with an accuracy ≤0.075 arc sec. A high quantum efficiency low-etaloning CCD detector allows operation at longer wavelengths. A patch panel allows input fibers to interface with interchangeable fiber holders that attach to a kinematic mount at the entrance slit. Computer-controlled hardware allows automated control of wavelength, timing, f-number, automated data collection, and wavelength calibration.

  10. Frequency doubling technique perimetry and spectral domain optical coherence tomography in patients with early glaucoma.

    Science.gov (United States)

    Horn, F K; Mardin, C Y; Bendschneider, D; Jünemann, A G; Adler, W; Tornow, R P

    2011-01-01

    To assess the combined diagnostic power of frequency-doubling technique (FDT)-perimetry and retinal nerve fibre layer (RNFL) thickness measurements with spectral domain optical coherence tomography (SDOCT). The study included 330 experienced participants in five age-related groups: 77 'preperimetric' open-angle glaucoma (OAG) patients, 52 'early' OAG, 50 'moderate' OAG, 54 ocular hypertensive patients, and 97 healthy subjects. For glaucoma assessment in all subjects conventional perimetry, evaluation of fundus photographs, FDT-perimetry and RNFL thickness measurement with SDOCT was done. Glaucomatous visual field defects were classified using the Glaucoma Staging System. FDT evaluation used a published method with casewise calculation of an 'FDT-score', including all missed localized probability levels. SDOCT evaluation used mean RNFL thickness and a new individual SDOCT-score considering normal confidence limits in 32 sectors of a peripapillary circular scan. To examine the joined value of both methods a combined score was introduced. Significance of the difference between Receiver-operating-characteristic (ROC) curves was calculated for a specificity of 96%. Sensitivity in the preperimetric glaucoma group was 44% for SDOCT-score, 25% for FDT-score, and 44% for combined score, in the early glaucoma group 83, 81, and 89%, respectively, and in the moderate glaucoma group 94, 94, and 98%, respectively, all at a specificity of 96%. ROC performance of the newly developed combined score is significantly above single ROC curves of FDT-score in preperimetric and early OAG and above RNFL thickness in moderate OAG. Combination of function and morphology by using the FDT-score and the SDOCT-score performs equal or even better than each single method alone.

  11. Ultra-high accuracy optical testing: creating diffraction-limited short-wavelength optical systems

    International Nuclear Information System (INIS)

    Goldberg, Kenneth A.; Naulleau, Patrick P.; Rekawa, Senajith B.; Denham, Paul E.; Liddle, J. Alexander; Gullikson, Eric M.; Jackson, KeithH.; Anderson, Erik H.; Taylor, John S.; Sommargren, Gary E.; Chapman, Henry N.; Phillion, Donald W.; Johnson, Michael; Barty, Anton; Soufli, Regina; Spiller, Eberhard A.; Walton, Christopher C.; Bajt, Sasa

    2005-01-01

    Since 1993, research in the fabrication of extreme ultraviolet (EUV) optical imaging systems, conducted at Lawrence Berkeley National Laboratory (LBNL) and Lawrence Livermore National Laboratory (LLNL), has produced the highest resolution optical systems ever made. We have pioneered the development of ultra-high-accuracy optical testing and alignment methods, working at extreme ultraviolet wavelengths, and pushing wavefront-measuring interferometry into the 2-20-nm wavelength range (60-600 eV). These coherent measurement techniques, including lateral shearing interferometry and phase-shifting point-diffraction interferometry (PS/PDI) have achieved RMS wavefront measurement accuracies of 0.5-1-(angstrom) and better for primary aberration terms, enabling the creation of diffraction-limited EUV optics. The measurement accuracy is established using careful null-testing procedures, and has been verified repeatedly through high-resolution imaging. We believe these methods are broadly applicable to the advancement of short-wavelength optical systems including space telescopes, microscope objectives, projection lenses, synchrotron beamline optics, diffractive and holographic optics, and more. Measurements have been performed on a tunable undulator beamline at LBNL's Advanced Light Source (ALS), optimized for high coherent flux; although many of these techniques should be adaptable to alternative ultraviolet, EUV, and soft x-ray light sources. To date, we have measured nine prototype all-reflective EUV optical systems with NA values between 0.08 and 0.30 (f/6.25 to f/1.67). These projection-imaging lenses were created for the semiconductor industry's advanced research in EUV photolithography, a technology slated for introduction in 2009-13. This paper reviews the methods used and our program's accomplishments to date

  12. Photonic crystal fibre enables short-wavelength two-photon laser scanning fluorescence microscopy with fura-2

    International Nuclear Information System (INIS)

    McConnell, Gail; Riis, Erling

    2004-01-01

    We report on a novel and compact reliable laser source capable of short-wavelength two-photon laser scanning fluorescence microscopy based on soliton self-frequency shift effects in photonic crystal fibre. We demonstrate the function of the system by performing two-photon microscopy of smooth muscle cells and cardiac myocytes from the rat pulmonary vein and Chinese hamster ovary cells loaded with the fluorescent calcium indicator fura-2/AM

  13. Short-wavelength luminescence in Ho{sup 3+}-doped KGd(WO{sub 4}){sub 2} crystals

    Energy Technology Data Exchange (ETDEWEB)

    Malinowski, M., E-mail: m.malinowski@elka.pw.edu.p [Institute of Microelectronics and Optoelectronics, Koszykowa 75, 00-662 Warsaw (Poland); Kaczkan, M.; Stopinski, S.; Piramidowicz, R. [Institute of Microelectronics and Optoelectronics, Koszykowa 75, 00-662 Warsaw (Poland); Majchrowski, A. [Institute of Applied Physics, Military University of Technology, Kaliskiego 2, 00-908 Warsaw (Poland)

    2009-12-15

    Emissions from the high-lying excited states, energy transfer and upconversion processes are investigated in Ho{sup 3+}-activated KGd(WO{sub 4}){sub 2} crystal. The spectral assignment based on time-resolved emission spectra allowed to identify various near ultra-violet (UV), blue and green emissions starting from the excited {sup 3}H{sub 5}, {sup 5}G{sub 4}, {sup 5}G{sub 5}, {sup 5}F{sub 3} and {sup 5}S{sub 2} levels. The temporal behavior of these transitions after pulsed excitation was analyzed as a function of temperature and holmium ions concentration. The shortening and nonexponentiality of the decays, observed with increasing activator concentrations, indicated cross-relaxation (CR) among the Ho{sup 3+} ions. Cross-relaxation rates were experimentally determined as a function of activator concentration and used to evaluate the values of the nearest-neighbor trapping rates X{sub 01} and to model the decays. It was observed that KGW, despite higher than in YAG maximum phonon energy of about 900 cm{sup -1}, is more efficient short-wavelength emitter than YAG. Examples of the excited-state absorption (ESA) and energy transfer (ET) mechanisms responsible for the upconverted, short-wavelength emissions were identified by analyzing fluorescence dynamics and possible energy resonances.

  14. Automated analysis of short responses in an interactive synthetic tutoring system for introductory physics

    Science.gov (United States)

    Nakamura, Christopher M.; Murphy, Sytil K.; Christel, Michael G.; Stevens, Scott M.; Zollman, Dean A.

    2016-06-01

    Computer-automated assessment of students' text responses to short-answer questions represents an important enabling technology for online learning environments. We have investigated the use of machine learning to train computer models capable of automatically classifying short-answer responses and assessed the results. Our investigations are part of a project to develop and test an interactive learning environment designed to help students learn introductory physics concepts. The system is designed around an interactive video tutoring interface. We have analyzed 9 with about 150 responses or less. We observe for 4 of the 9 automated assessment with interrater agreement of 70% or better with the human rater. This level of agreement may represent a baseline for practical utility in instruction and indicates that the method warrants further investigation for use in this type of application. Our results also suggest strategies that may be useful for writing activities and questions that are more appropriate for automated assessment. These strategies include building activities that have relatively few conceptually distinct ways of perceiving the physical behavior of relatively few physical objects. Further success in this direction may allow us to promote interactivity and better provide feedback in online learning systems. These capabilities could enable our system to function more like a real tutor.

  15. Automated analysis of short responses in an interactive synthetic tutoring system for introductory physics

    Directory of Open Access Journals (Sweden)

    Christopher M. Nakamura

    2016-03-01

    Full Text Available Computer-automated assessment of students’ text responses to short-answer questions represents an important enabling technology for online learning environments. We have investigated the use of machine learning to train computer models capable of automatically classifying short-answer responses and assessed the results. Our investigations are part of a project to develop and test an interactive learning environment designed to help students learn introductory physics concepts. The system is designed around an interactive video tutoring interface. We have analyzed 9 with about 150 responses or less. We observe for 4 of the 9 automated assessment with interrater agreement of 70% or better with the human rater. This level of agreement may represent a baseline for practical utility in instruction and indicates that the method warrants further investigation for use in this type of application. Our results also suggest strategies that may be useful for writing activities and questions that are more appropriate for automated assessment. These strategies include building activities that have relatively few conceptually distinct ways of perceiving the physical behavior of relatively few physical objects. Further success in this direction may allow us to promote interactivity and better provide feedback in online learning systems. These capabilities could enable our system to function more like a real tutor.

  16. Emitted short wavelength infrared radiation for detection and monitoring of volcanic activity

    Science.gov (United States)

    Rothery, D. A.; Francis, P. W.; Wood, C. A.

    1988-01-01

    Thematic Mapper images from LANDSAT were used to monitor volcanoes. Achievements include: (1) the discovery of a magmatic precursor to the 16 Sept. 1986 eruption of Lascar, northern Chile, on images from Mar. and July 1985 and of continuing fumarolic activity after the eruption; (2) the detection of unreported major changes in the distribution of lava lakes on Erta'Ale, Ethiopia; and (3) the mapping of a halo of still-hot spatter surrounding a vent on Mount Erebus, Antarctica, on an image acquired 5 min after a minor eruption otherwise known only from seismic records. A spaceborne short wavelength infrared sensor for observing hot phenomena of volcanoes is proposed. A polar orbit is suggested.

  17. Short-wavelength ablation of polymers in the high-fluence regime

    International Nuclear Information System (INIS)

    Liberatore, Chiara; Juha, Libor; Vyšín, Ludek; Endo, Akira; Mocek, Tomas; Mann, Klaus; Müller, Matthias; Pina, Ladislav; Rocca, Jorge J

    2014-01-01

    Short-wavelength ablation of poly(1,4-phenylene ether-ether-sulfone) (PPEES) and poly(methyl methacrylate) (PMMA) was investigated using extreme ultraviolet (XUV) and soft x-ray (SXR) radiation from plasma-based sources. The initial experiment was performed with a 10 Hz desktop capillary-discharge XUV laser lasing at 46.9 nm. The XUV laser beam was focused onto the sample by a spherical mirror coated with a Si/Sc multilayer. The same materials were irradiated with 13.5 nm radiation emitted by plasmas produced by focusing an optical laser beam onto a xenon gas-puff target. A Schwarzschild focusing optics coated with a Mo/Si multilayer was installed at the source to achieve energy densities exceeding 0.1 J cm −2 in the tight focus. The existing experimental system at the Laser Laboratorium Göttingen was upgraded by implementing a 1.2 J driving laser. An increase of the SXR fluence was secured by improving the alignment technique. (paper)

  18. Wavelength-stepped, actively mode-locked fiber laser based on wavelength-division-multiplexed optical delay lines

    Science.gov (United States)

    Lee, Eunjoo; Kim, Byoung Yoon

    2017-12-01

    We propose a new scheme for an actively mode-locked wavelength-swept fiber laser that produces a train of discretely wavelength-stepped pulses from a short fiber cavity. Pulses with different wavelengths are split and combined by standard wavelength division multiplexers with fiber delay lines. As a proof of concept, we demonstrate a laser using an erbium doped fiber amplifier and commercially available wavelength-division multiplexers with wavelength spacing of 0.8 nm. The results show simultaneous mode-locking at three different wavelengths. Laser output parameters in time domain, optical and radio frequency spectral domain, and the noise characteristics are presented. Suggestions for the improved design are discussed.

  19. Temperature distribution and heat radiation of patterned surfaces at short wavelengths

    Science.gov (United States)

    Emig, Thorsten

    2017-05-01

    We analyze the equilibrium spatial distribution of surface temperatures of patterned surfaces. The surface is exposed to a constant external heat flux and has a fixed internal temperature that is coupled to the outside heat fluxes by finite heat conductivity across the surface. It is assumed that the temperatures are sufficiently high so that the thermal wavelength (a few microns at room temperature) is short compared to all geometric length scales of the surface patterns. Hence the radiosity method can be employed. A recursive multiple scattering method is developed that enables rapid convergence to equilibrium temperatures. While the temperature distributions show distinct dependence on the detailed surface shapes (cuboids and cylinder are studied), we demonstrate robust universal relations between the mean and the standard deviation of the temperature distributions and quantities that characterize overall geometric features of the surface shape.

  20. Comparison of 30-2 Standard and Fast programs of Swedish Interactive Threshold Algorithm of Humphrey Field Analyzer for perimetry in patients with intracranial tumors.

    Science.gov (United States)

    Singh, Manav Deep; Jain, Kanika

    2017-11-01

    To find out whether 30-2 Swedish Interactive Threshold Algorithm (SITA) Fast is comparable to 30-2 SITA Standard as a tool for perimetry among the patients with intracranial tumors. This was a prospective cross-sectional study involving 80 patients aged ≥18 years with imaging proven intracranial tumors and visual acuity better than 20/60. The patients underwent multiple visual field examinations using the two algorithms till consistent and repeatable results were obtained. A total of 140 eyes of 80 patients were analyzed. Almost 60% of patients undergoing perimetry with SITA Standard required two or more sessions to obtain consistent results, whereas the same could be obtained in 81.42% with SITA Fast in the first session itself. Of 140 eyes, 70 eyes had recordable field defects and the rest had no defects as detected by either of the two algorithms. Mean deviation (MD) (P = 0.56), pattern standard deviation (PSD) (P = 0.22), visual field index (P = 0.83) and number of depressed points at P 0.5% on MD and PSD probability plots showed no statistically significant difference between two algorithms. Bland-Altman test showed that considerable variability existed between two algorithms. Perimetry performed by SITA Standard and SITA Fast algorithm of Humphrey Field Analyzer gives comparable results among the patients of intracranial tumors. Being more time efficient and with a shorter learning curve, SITA Fast my be recommended as a standard test for the purpose of perimetry among these patients.

  1. Laser spectroscopy of the products of photoevaporation with a short-wavelength (λ = 193 nm) excimer laser

    International Nuclear Information System (INIS)

    Gochelashvili, K S; Zemskov, M E; Evdokimova, O N; Mikhkel'soo, V T; Prokhorov, A M

    1999-01-01

    An excimer laser spectrometer was designed and constructed. It consists of a high-vacuum interaction chamber, a short-wavelength (λ = 193 nm) excimer ArF laser used for evaporation, a probe dye laser pumped by an XeCl excimer laser, and a system for recording a laser-induced fluorescence signal. This spectrometer was used to investigate nonthermal mechanisms of photoevaporation of a number of wide-gap dielectrics. (laser applications and other topics in quantum electronics)

  2. Ultrafast terawatt laser sources for high-field particle acceleration and short wavelength generation

    International Nuclear Information System (INIS)

    Downer, M.C.

    1996-01-01

    The Laser Sources working group concerned itself with recent advances in and future requirements for the development of laser sources relevant to high-energy physics (HEP) colliders, small scale accelerators, and the generation of short wave-length radiation. We heavily emphasized pulsed terawatt peak power laser sources for several reasons. First, their development over the past five years has been rapid and multi-faceted, and has made relativistic light intensity available to the advanced accelerator community, as well as the wider physics community, for the first time. Secondly, they have strongly impacted plasma-based accelerator research over the past two years, producing the first experimental demonstrations of the laser wakefield accelerator (LWFA) in both its resonantly-driven and self-modulated forms. Thirdly, their average power and wall-plug efficiency currently fall well short of projected requirements for future accelerators and other high average power applications, but show considerable promise for improving substantially over the next few years. A review of this rapidly emerging laser technology in the context of advanced accelerator research is therefore timely

  3. Visual discrimination training improves Humphrey perimetry in chronic cortically induced blindness.

    Science.gov (United States)

    Cavanaugh, Matthew R; Huxlin, Krystel R

    2017-05-09

    To assess if visual discrimination training improves performance on visual perimetry tests in chronic stroke patients with visual cortex involvement. 24-2 and 10-2 Humphrey visual fields were analyzed for 17 chronic cortically blind stroke patients prior to and following visual discrimination training, as well as in 5 untrained, cortically blind controls. Trained patients practiced direction discrimination, orientation discrimination, or both, at nonoverlapping, blind field locations. All pretraining and posttraining discrimination performance and Humphrey fields were collected with online eye tracking, ensuring gaze-contingent stimulus presentation. Trained patients recovered ∼108 degrees 2 of vision on average, while untrained patients spontaneously improved over an area of ∼16 degrees 2 . Improvement was not affected by patient age, time since lesion, size of initial deficit, or training type, but was proportional to the amount of training performed. Untrained patients counterbalanced their improvements with worsening of sensitivity over ∼9 degrees 2 of their visual field. Worsening was minimal in trained patients. Finally, although discrimination performance improved at all trained locations, changes in Humphrey sensitivity occurred both within trained regions and beyond, extending over a larger area along the blind field border. In adults with chronic cortical visual impairment, the blind field border appears to have enhanced plastic potential, which can be recruited by gaze-controlled visual discrimination training to expand the visible field. Our findings underscore a critical need for future studies to measure the effects of vision restoration approaches on perimetry in larger cohorts of patients. Copyright © 2017 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Neurology.

  4. Study of short wavelength turbulence in dense plasmas. Final technical report, September 8, 1981-August 7, 1983

    International Nuclear Information System (INIS)

    Chen, F.F.; Joshi, C.

    1983-10-01

    The work includes studies of four topics: (1) Thomson scattering from short wavelength density fluctuations from laser excited plasmas from solid targets; (2) studies of SBS driven ion acoustic waves and it's harmonics in underdense plasmas; (3) studies of optical mixing excitation of electron plasma waves (high frequency density fluctuations) in theta pinch plasma; and (4) computational studies of high frequency wave excitation by intense laser beams in plasmas

  5. NEURO-OPHTHALMOLOGY

    African Journals Online (AJOL)

    headache of 2 years duration and visual loss left eye (LE). She was ... perimetry confirmed a right homonymous hemianopia and Cranial CT scan showed a suprasellar ... Magnetic resonance imaging brain was ordered and neurosurgery ... as a function of decibel sensitivity loss on automated static perimetry. Implications ...

  6. The Effective Dynamic Ranges for Glaucomatous Visual Field Progression With Standard Automated Perimetry and Stimulus Sizes III and V.

    Science.gov (United States)

    Wall, Michael; Zamba, Gideon K D; Artes, Paul H

    2018-01-01

    It has been shown that threshold estimates below approximately 20 dB have little effect on the ability to detect visual field progression in glaucoma. We aimed to compare stimulus size V to stimulus size III, in areas of visual damage, to confirm these findings by using (1) a different dataset, (2) different techniques of progression analysis, and (3) an analysis to evaluate the effect of censoring on mean deviation (MD). In the Iowa Variability in Perimetry Study, 120 glaucoma subjects were tested every 6 months for 4 years with size III SITA Standard and size V Full Threshold. Progression was determined with three complementary techniques: pointwise linear regression (PLR), permutation of PLR, and linear regression of the MD index. All analyses were repeated on "censored'' datasets in which threshold estimates below a given criterion value were set to equal the criterion value. Our analyses confirmed previous observations that threshold estimates below 20 dB contribute much less to visual field progression than estimates above this range. These findings were broadly similar with stimulus sizes III and V. Censoring of threshold values < 20 dB has relatively little impact on the rates of visual field progression in patients with mild to moderate glaucoma. Size V, which has lower retest variability, performs at least as well as size III for longitudinal glaucoma progression analysis and appears to have a larger useful dynamic range owing to the upper sensitivity limit being higher.

  7. Surface Variability of Short-wavelength Radiation and Temperature on Exoplanets around M Dwarfs

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xin; Tian, Feng [Ministry of Education Key Laboratory for Earth System Modeling, Department of Earth System Science, Tsinghua University, Beijing 100084 (China); Wang, Yuwei [Department of Atmospheric and Oceanic Sciences, McGill University, Montreal, QC H3A 0B9 (Canada); Dudhia, Jimy; Chen, Ming, E-mail: tianfengco@tsinghua.edu.cn [National Center for Atmospheric Research, Boulder, CO (United States)

    2017-03-10

    It is a common practice to use 3D General Circulation Models (GCM) with spatial resolution of a few hundred kilometers to simulate the climate of Earth-like exoplanets. The enhanced albedo effect of clouds is especially important for exoplanets in the habitable zones around M dwarfs that likely have fixed substellar regions and substantial cloud coverage. Here, we carry out mesoscale model simulations with 3 km spatial resolution driven by the initial and boundary conditions in a 3D GCM and find that it could significantly underestimate the spatial variability of both the incident short-wavelength radiation and the temperature at planet surface. Our findings suggest that mesoscale models with cloud-resolving capability be considered for future studies of exoplanet climate.

  8. Recovery Of Short Wavelength Geophysical Signals With Future Delay-Doppler Altimeters (Cryosat Ii And Sentinel Type)

    DEFF Research Database (Denmark)

    Andersen, Ole Baltazar

    2010-01-01

    altimetry: Factor of 20 improvements in along track resolution. An along-track footprint length that does not vary with wave height (sea state). Twice the precision in sea surface height measurements / sea surface slope measurements. These improvements are studied with respect to retrieval of short...... wavelength geophysical signal related to mainly bathymetric features. The combination of upward continuation from the sea bottom and smoothing the altimeter observations resulted in the best recovery of geophysical signal for simulated 5-Hz DD observations. Simulations carried out in this investigation...

  9. Magneto-optical enhancement of TbFeCo/Al films at short wavelength

    International Nuclear Information System (INIS)

    Song, K.; Ito, H.; Naoe, M.

    1992-01-01

    In this paper, the bilayered films composed of magneto-optical (MO) amorphous Tb-Te-Co alloy and reflective Al layers were deposited successively on glass slide substrates without plasma exposure by using the facing targets sputtering system. The specimen films with the thickness of MO layer t MO below 5 nm showed apparent perpendicular magnetic anisotropy constant Ku of 2 to 3 x 10 6 erg/cm3 and rectangular Kerr loop. The specimen film with t MO of 14 nm took the Kerr rotation angle θ k as large as about 0.36 degree, at the wavelength λ as short as about 400 nm. These values of θ k is considerably larger than those of the bilayered films in the conventional MO media. Normally, the bilayered films with t MO above 50 nm took θ k of about 0.25 degree at θ k of 400 nm

  10. Losses of functional opsin genes, short-wavelength cone photopigments, and color vision--a significant trend in the evolution of mammalian vision.

    Science.gov (United States)

    Jacobs, Gerald H

    2013-03-01

    All mammalian cone photopigments are derived from the operation of representatives from two opsin gene families (SWS1 and LWS in marsupial and eutherian mammals; SWS2 and LWS in monotremes), a process that produces cone pigments with respective peak sensitivities in the short and middle-to-long wavelengths. With the exception of a number of primate taxa, the modal pattern for mammals is to have two types of cone photopigment, one drawn from each of the gene families. In recent years, it has been discovered that the SWS1 opsin genes of a widely divergent collection of eutherian mammals have accumulated mutational changes that render them nonfunctional. This alteration reduces the retinal complements of these species to a single cone type, thus rendering ordinary color vision impossible. At present, several dozen species from five mammalian orders have been identified as falling into this category, but the total number of mammalian species that have lost short-wavelength cones in this way is certain to be much larger, perhaps reaching as high as 10% of all species. A number of circumstances that might be used to explain this widespread cone loss can be identified. Among these, the single consistent fact is that the species so affected are nocturnal or, if they are not technically nocturnal, they at least feature retinal organizations that are typically associated with that lifestyle. At the same time, however, there are many nocturnal mammals that retain functional short-wavelength cones. Nocturnality thus appears to set the stage for loss of functional SWS1 opsin genes in mammals, but it cannot be the sole circumstance.

  11. Multi-wavelength mid-IR light source for gas sensing

    Science.gov (United States)

    Karioja, Pentti; Alajoki, Teemu; Cherchi, Matteo; Ollila, Jyrki; Harjanne, Mikko; Heinilehto, Noora; Suomalainen, Soile; Viheriälä, Jukka; Zia, Nouman; Guina, Mircea; Buczyński, Ryszard; Kasztelanic, Rafał; Kujawa, Ireneusz; Salo, Tomi; Virtanen, Sami; Kluczyński, Paweł; Sagberg, Hâkon; Ratajczyk, Marcin; Kalinowski, Przemyslaw

    2017-02-01

    Cost effective multi-wavelength light sources are key enablers for wide-scale penetration of gas sensors at Mid-IR wavelength range. Utilizing novel Mid-IR Si-based photonic integrated circuits (PICs) filter and wide-band Mid-IR Super Luminescent Light Emitting Diodes (SLEDs), we show the concept of a light source that covers 2.5…3.5 μm wavelength range with a resolution of price can be lowered in high volumes by utilizing tailored molded IR lens technology and automated packaging and assembling technologies. The status of the development of the key components of the light source are reported. The PIC is based on the use of micron-scale SOI technology, SLED is based on AlGaInAsSb materials and the lenses are tailored heavy metal oxide glasses fabricated by the use of hot-embossing. The packaging concept utilizing automated assembly tools is depicted. In safety and security applications, the Mid-IR wavelength range covered by the novel light source allows for detecting several harmful gas components with a single sensor. At the moment, affordable sources are not available. The market impact is expected to be disruptive, since the devices currently in the market are either complicated, expensive and heavy instruments, or the applied measurement principles are inadequate in terms of stability and selectivity.

  12. Scaling model for high-aspect-ratio microballoon direct-drive implosions at short laser wavelengths

    International Nuclear Information System (INIS)

    Schirmann, D.; Juraszek, D.; Lane, S.M.; Campbell, E.M.

    1992-01-01

    A scaling model for hot spherical ablative implosions in direct-drive mode is presented. The model results have been compared with experiments from LLE, ILE, and LLNL. Reduction of the neutron yield due to illumination nonuniformities is taken into account by the assumption that the neutron emission is cut off when the gas shock wave reflected off the center meets the incoming pusher, i.e., at a time when the probability of shell breakup is greatly enhanced. The main advantage of this semiempirical scaling model is that it elucidates the principal features of these simple implosions and permits one to estimate very quickly the performance of a high-aspect-ratio direct-drive target illuminated by short-wavelength laser light. (Author)

  13. Paraconductivity of three-dimensional amorphous superconductors: evidence for a short-wavelength cutoff in the fluctuation spectrum

    International Nuclear Information System (INIS)

    Johnson, W.L.

    1977-10-01

    Measurements of the temperature dependence and magnetic field dependence of the paraconductivity of a three dimensional amorphous superconductor are presented. The data are analyzed in terms of several current theories and are found to give good agreement for low fields and temperatures near T/sub c/. The paraconductivity falls well below predicted theoretical values in the high temperature and high field limits. This is attributed to the reduced role of high wavevector contributions to the paraconductivity. It is shown that the introduction of a short wavelength cutoff in the theoretical fluctuation spectrum provides a phenomelogical account of the discrepancy between theory and experiment

  14. Interferometry on small quantum systems at short wavelength

    Energy Technology Data Exchange (ETDEWEB)

    Usenko, Sergey

    2017-01-15

    The present work concentrates on prototypical studies of light-induced correlated many-body dynamics in complex systems. In its course a reflective split-and-delay unit (SDU) for phase-resolved one-color pump-probe experiments with gas phase samples using VUV-XUV laser pulses was built. The collinear propagation of pump and probe pulses is ensured by the special geometry of the SDU and allows to perform phase-resolved (coherent) autocorrelation measurements. The control of the pump-probe delay with attosecond precision is established by a specially developed diagnostic tool based on an in-vacuum white light interferometer that allows to monitor the relative displacement of the SDU reflectors with nanometer resolution. Phase-resolved (interferometric) pump-probe experiments with developed SDU require spatially-resolved imaging of the ionization volume. For this an electron-ion coincidence spectrometer was built. The spectrometer enables coincident detection of photoionization products using velocity map imaging (VMI) technique for electrons and VMI or spatial imaging for ions. In first experiments using the developed SDU and the spectrometer in the ion spatial-imaging mode linear field autocorrelation of free-electron laser pulses at the central wavelength of 38 nm was recorded. A further focus of the work were energy- and time-resolved resonant two-photon ionization experiments using short tunable UV laser pulses on C{sub 60} fullerene. The experiments demonstrated that dipole-selective excitation on a timescale faster than the characteristic intramolecular energy dissipation limits the number of accessible excitation pathways and thus results in a narrow resonance. Time-dependent one-color pump-probe study showed that nonadiabatic (vibron) coupling is the dominant energy dissipation mechanism for high-lying electronic excited states in C{sub 60}.

  15. Interferometry on small quantum systems at short wavelength

    International Nuclear Information System (INIS)

    Usenko, Sergey

    2017-01-01

    The present work concentrates on prototypical studies of light-induced correlated many-body dynamics in complex systems. In its course a reflective split-and-delay unit (SDU) for phase-resolved one-color pump-probe experiments with gas phase samples using VUV-XUV laser pulses was built. The collinear propagation of pump and probe pulses is ensured by the special geometry of the SDU and allows to perform phase-resolved (coherent) autocorrelation measurements. The control of the pump-probe delay with attosecond precision is established by a specially developed diagnostic tool based on an in-vacuum white light interferometer that allows to monitor the relative displacement of the SDU reflectors with nanometer resolution. Phase-resolved (interferometric) pump-probe experiments with developed SDU require spatially-resolved imaging of the ionization volume. For this an electron-ion coincidence spectrometer was built. The spectrometer enables coincident detection of photoionization products using velocity map imaging (VMI) technique for electrons and VMI or spatial imaging for ions. In first experiments using the developed SDU and the spectrometer in the ion spatial-imaging mode linear field autocorrelation of free-electron laser pulses at the central wavelength of 38 nm was recorded. A further focus of the work were energy- and time-resolved resonant two-photon ionization experiments using short tunable UV laser pulses on C_6_0 fullerene. The experiments demonstrated that dipole-selective excitation on a timescale faster than the characteristic intramolecular energy dissipation limits the number of accessible excitation pathways and thus results in a narrow resonance. Time-dependent one-color pump-probe study showed that nonadiabatic (vibron) coupling is the dominant energy dissipation mechanism for high-lying electronic excited states in C_6_0.

  16. Clinical application of automated Greulich-Pyle bone age determination in children with short stature

    International Nuclear Information System (INIS)

    Martin, David D.; Deusch, Dorothee; Schweizer, Roland; Binder, Gerhard; Ranke, Michael B.; Thodberg, Hans Henrik

    2009-01-01

    Bone age (BA) rating is time consuming and highly rater dependent. To adjust the fully automated BoneXpert method to agree with the manual Greulich and Pyle BA (GP BA) ratings of five raters and to validate the accuracy for short children. A total of 1,097 left hand radiographs from 188 children with short stature, including growth hormone deficiency (44%) and Turner syndrome (29%) were evaluated. BoneXpert rejected 14 of the 1,097 radiographs, and deviated by more than 1.9 years from the operator BA for 27 radiographs. These were rerated blindly by four operators. Of the 27 new ratings, 26 were within 1.9 years of the automatic BA values. The root mean square deviation between manual and automatic rating was 0.72 years (95% CI 0.69-0.75). BoneXpert's ability to process 99% of images automatically without errors, and to obtain good agreement with an operator suggests that the method is efficient and reliable for short children. (orig.)

  17. Clinical application of automated Greulich-Pyle bone age determination in children with short stature

    Energy Technology Data Exchange (ETDEWEB)

    Martin, David D.; Deusch, Dorothee; Schweizer, Roland; Binder, Gerhard; Ranke, Michael B. [University Children' s Hospital, Paediatric Endocrinology Section, Tuebingen (Germany); Thodberg, Hans Henrik [Visiana, Holte (Denmark)

    2009-06-15

    Bone age (BA) rating is time consuming and highly rater dependent. To adjust the fully automated BoneXpert method to agree with the manual Greulich and Pyle BA (GP BA) ratings of five raters and to validate the accuracy for short children. A total of 1,097 left hand radiographs from 188 children with short stature, including growth hormone deficiency (44%) and Turner syndrome (29%) were evaluated. BoneXpert rejected 14 of the 1,097 radiographs, and deviated by more than 1.9 years from the operator BA for 27 radiographs. These were rerated blindly by four operators. Of the 27 new ratings, 26 were within 1.9 years of the automatic BA values. The root mean square deviation between manual and automatic rating was 0.72 years (95% CI 0.69-0.75). BoneXpert's ability to process 99% of images automatically without errors, and to obtain good agreement with an operator suggests that the method is efficient and reliable for short children. (orig.)

  18. Short-wavelength InAlGaAs/AlGaAs quantum dot superluminescent diodes

    Science.gov (United States)

    Liang, De-Chun; An, Qi; Jin, Peng; Li, Xin-Kun; Wei, Heng; Wu, Ju; Wang, Zhan-Guo

    2011-10-01

    This paper reports the fabrication of J-shaped bent-waveguide superluminescent diodes utilizing an InAlGaAs/AlGaAs quantum dot active region. The emission spectrum of the device is centred at 884 nm with a full width at half maximum of 37 nm and an output power of 18 mW. By incorporating an Al composition into the quantum dot active region, short-wavelength superluminescent diode devices can be obtained. An intersection was found for the light power-injection current curves measured from the straight-waveguide facet and the bent-waveguide facet, respectively. The result is attributed to the conjunct effects of the gain and the additional loss of the bent waveguide. A numerical simulation is performed to verify the qualitative explanation. It is shown that bent waveguide loss is an important factor that affects the output power of J-shaped superluminescent diode devices.

  19. Towards shorter wavelength x-ray lasers using a high power, short pulse pump laser

    International Nuclear Information System (INIS)

    Tighe, W.; Krushelnick, K.; Valeo, E.; Suckewer, S.

    1991-05-01

    A near-terawatt, KrF* laser system, focussable to power densities >10 18 W/cm 2 has been constructed for use as a pump laser in various schemes aimed at the development of x-ray lasing below 5nm. The laser system along with output characteristics such as the pulse duration, the focal spot size, and the percentage of amplified spontaneous emission (ASE) emitted along with the laser pulse will be presented. Schemes intended to lead to shorter wavelength x-ray emission will be described. The resultant requirements on the pump laser characteristics and the target design will be outlined. Results from recent solid target experiments and two-laser experiments, showing the interaction of a high-power, short pulse laser with a preformed plasma, will be presented. 13 refs., 5 figs

  20. Multi-photon ionization of atoms in intense short-wavelength radiation fields

    Science.gov (United States)

    Meyer, Michael

    2015-05-01

    The unprecedented characteristics of XUV and X-ray Free Electron Lasers (FELs) have stimulated numerous investigations focusing on the detailed understanding of fundamental photon-matter interactions in atoms and molecules. In particular, the high intensities (up to 106 W/cm2) giving rise to non-linear phenomena in the short wavelength regime. The basic phenomenology involves the production of highly charged ions via electron emission to which both sequential and direct multi-photon absorption processes contribute. The detailed investigation of the role and relative weight of these processes under different conditions (wavelength, pulse duration, intensity) is the key element for a comprehensive understanding of the ionization dynamics. Here the results of recent investigations are presented, performed at the FELs in Hamburg (FLASH) and Trieste (FERMI) on atomic systems with electronic structures of increasing complexity (Ar, Ne and Xe). Mainly, electron spectroscopy is used to obtain quantitative information about the relevance of various multi-photon ionization processes. For the case of Ar, a variety of processes including above threshold ionization (ATI) from 3p and 3s valence shells, direct 2p two-photon ionization and resonant 2p-4p two-photon excitations were observed and their role was quantitatively determined comparing the experimental ionization yields to ab-initio calculations of the cross sections for the multi-photon processes. Using Ar as a benchmark to prove the reliability of the combined experimental and theoretical approach, the more complex and intriguing case of Xe was studied. Especially, the analysis of the two-photon ATI from the Xe 4d shell reveals new insight into the character of the 4d giant resonance, which was unresolved in the linear one-photon regime. Finally, the influence of intense XUV radiation to the relaxation dynamics of the Ne 2s-3p resonance was investigated by angle-resolved electron spectroscopy, especially be observing

  1. TES arrays for the short wavelength band of the SAFARI instrument on SPICA

    Science.gov (United States)

    Khosropanah, P.; Hijmering, R.; Ridder, M.; Gao, J. R.; Morozov, D.; Mauskopf, P. D.; Trappe, N.; O'Sullivan, C.; Murphy, A.; Griffin, D.; Goldie, D.; Glowacka, D.; Withington, S.; Jackson, B. D.; Audley, M. D.; de Lange, G.

    2012-09-01

    SPICA is an infra-red (IR) telescope with a cryogenically cooled mirror (~5K) with three instruments on board, one of which is SAFARI that is an imaging Fourier Transform Spectrometer (FTS) with three bands covering the wavelength of 34-210 μm. We develop transition edge sensors (TES) array for short wavelength band (34-60 μm) of SAFARI. These are based on superconducting Ti/Au bilayer as TES bolometers with a Tc of about 105 mK and thin Ta film as IR absorbers on suspended silicon nitride (SiN) membranes. These membranes are supported by long and narrow SiN legs that act as weak thermal links between the TES and the bath. Previously an electrical noise equivalent power (NEP) of 4×10-19 W/√Hz was achieved for a single pixel of such detectors. As an intermediate step toward a full-size SAFARI array (43×43), we fabricated several 8×9 detector arrays. Here we describe the design and the outcome of the dark and optical tests of several of these devices. We achieved high yield (<93%) and high uniformity in terms of critical temperature (<5%) and normal resistance (7%) across the arrays. The measured dark NEPs are as low as 5×10-19 W/√Hz with a response time of about 1.4 ms at preferred operating bias point. The optical coupling is implemented using pyramidal horns array on the top and hemispherical cavity behind the chip that gives a measured total optical coupling efficiency of 30±7%.

  2. Monolithic photonic integration for visible and short near-infrared wavelengths: technologies and platforms for bio and life science applications

    Science.gov (United States)

    Porcel, Marco A. G.; Artundo, Iñigo; Domenech, J. David; Geuzebroek, Douwe; Sunarto, Rino; Hoofman, Romano

    2018-04-01

    This tutorial aims to provide a general overview on the state-of-the-art of photonic integrated circuits (PICs) in the visible and short near-infrared (NIR) wavelength ranges, mostly focusing in silicon nitride (SiN) substrates, and a guide to the necessary steps in the design toward the fabrication of such PICs. The focus is put on bio- and life sciences, given the adequacy and, thus, a large number of applications in this field.

  3. Observation of Rayleigh - Taylor growth to short wavelengths on Nike

    International Nuclear Information System (INIS)

    Pawley, C.J.; Bodner, S.E.; Dahlburg, J.P.; Obenschain, S.P.; Schmitt, A.J.; Sethian, J.D.; Sullivan, C.A.; Gardner, J.H.; Aglitskiy, Y.; Chan, Y.; Lehecka, T.

    1999-01-01

    The uniform and smooth focal profile of the Nike KrF laser [S. Obenschain et al., Phys. Plasmas 3, 2098 (1996)] was used to ablatively accelerate 40 μm thick polystyrene planar targets with pulse shaping to minimize shock heating of the compressed material. The foils had imposed small-amplitude sinusoidal wave perturbations of 60, 30, 20, and 12.5 μm wavelength. The shortest wavelength is near the ablative stabilization cutoff for Rayleigh - Taylor growth. Modification of the saturated wave structure due to random laser imprint was observed. Excellent agreement was found between the two-dimensional simulations and experimental data for most cases where the laser imprint was not dominant. copyright 1999 American Institute of Physics

  4. Investigation of concept of efficient short wavelength laser. Final technical report, April 1, 1977-July 31, 1979

    International Nuclear Information System (INIS)

    Piper, L.G.; Krech, R.H.; Pugh, E.; Taylor, R.L.

    1979-01-01

    The feasibility of producing an efficient, short wavelength, storage laser for ICF driven applications by making use of certain state-specific reactions of exoergic azide compounds has been investigated. The ultraviolet (approx. 300 nm) photolysis of gaseous ClN 3 produced prompt emission in the red, which was attributed to the efficient formation of ClN(b 1 Σ + ) with subsequent ClN(X reverse arrow b) fluorescence. Based on these results, a small-scale laser demonstration experiment was constructed using short duration Xe flash lamps as the photolytic source. The results of this latter experiment were negative. The most plausible explanation was that the flash lamps provided sufficient far-uv radiation to dissociate and/or ionize the ClN(b) produced in the primary photolytic step. In parallel, limited experiments were performed on the rapid pyrolysis of a solid, ionic azide, NaN 3 , to produce gaseous N 3 radicals and subsequent production of triplet N 2 molecules

  5. Optimization of a miniature short-wavelength infrared objective optics of a short-wavelength infrared to visible upconversion layer attached to a mobile-devices visible camera

    Science.gov (United States)

    Kadosh, Itai; Sarusi, Gabby

    2017-10-01

    The use of dual cameras in parallax in order to detect and create 3-D images in mobile devices has been increasing over the last few years. We propose a concept where the second camera will be operating in the short-wavelength infrared (SWIR-1300 to 1800 nm) and thus have night vision capability while preserving most of the other advantages of dual cameras in terms of depth and 3-D capabilities. In order to maintain commonality of the two cameras, we propose to attach to one of the cameras a SWIR to visible upconversion layer that will convert the SWIR image into a visible image. For this purpose, the fore optics (the objective lenses) should be redesigned for the SWIR spectral range and the additional upconversion layer, whose thickness is mobile device visible range camera sensor (the CMOS sensor). This paper presents such a SWIR objective optical design and optimization that is formed and fit mechanically to the visible objective design but with different lenses in order to maintain the commonality and as a proof-of-concept. Such a SWIR objective design is very challenging since it requires mimicking the original visible mobile camera lenses' sizes and the mechanical housing, so we can adhere to the visible optical and mechanical design. We present in depth a feasibility study and the overall optical system performance of such a SWIR mobile-device camera fore optics design.

  6. Improved performance of P3HT:PCBM solar cells by both anode modification and short-wavelength energy utilization using Tb(aca)3phen

    International Nuclear Information System (INIS)

    Zhuo Zu-Liang; Wang Yong-Sheng; He Da-Wei; Fu Ming

    2014-01-01

    The performance of P3HT:PCBM solar cells was improved by anode modification using spin-coated Tb(aca) 3 phen ultrathin films. The modification of the Tb(aca) 3 phen ultrathin film between the indium tin oxide (ITO) anode and the PE-DOT:PSS layer resulted in a maximum power conversion efficiency (PCE) of 2.99% compared to 2.66% for the reference device, which was due to the increase in the short-circuit current density (J sc ). The PCE improvement could be attributed to the short-wavelength energy utilization and the optimized morphology of the active layers. Tb(aca) 3 phen with its strong down-conversion luminescence properties is suitable for the P3HT:PCBM blend active layer, and the absorption region of the ternary blend films is extended into the near ultraviolet region. Furthermore, the crystallization and the surface morphology of P3HT:PCBM films were improved with the Tb(aca) 3 phen ultrathin film. The ultraviolent—visible absorption spectra, atomic force microscope (AFM), and X-ray diffraction (XRD) of the films were investigated. Both anode modification and short-wavelength energy utilization using Tb(aca) 3 phen in P3HT:PCBM solar cells led to about a 12% PCE increase. (interdisciplinary physics and related areas of science and technology)

  7. Hardware and software for automating the process of studying high-speed gas flows in wind tunnels of short-term action

    Science.gov (United States)

    Yakovlev, V. V.; Shakirov, S. R.; Gilyov, V. M.; Shpak, S. I.

    2017-10-01

    In this paper, we propose a variant of constructing automation systems for aerodynamic experiments on the basis of modern hardware-software means of domestic development. The structure of the universal control and data collection system for performing experiments in wind tunnels of continuous, periodic or short-term action is proposed. The proposed hardware and software development tools for ICT SB RAS and ITAM SB RAS, as well as subsystems based on them, can be widely applied to any scientific and experimental installations, as well as to the automation of technological processes in production.

  8. Interrogation of weak Bragg grating sensors based on dual-wavelength differential detection.

    Science.gov (United States)

    Cheng, Rui; Xia, Li

    2016-11-15

    It is shown that for weak Bragg gratings the logarithmic ratio of reflected intensities at any two wavelengths within the spectrum follows a linear relationship with the Bragg wavelength shift, with a slope proportional to their wavelength spacing. This finding is exploited to develop a flexible, efficient, and cheap interrogation solution of weak fiber Bragg grating (FBGs), especially ultra-short FBGs, in distributed sensing based on dual-wavelength differential detection. The concept is experimentally studied in both single and distributed sensing systems with ultra-short FBG sensors. The work may form the basis of new and promising FBG interrogation techniques based on detecting discrete rather than continuous spectra.

  9. The Effect of Cataract on Eye Movement Perimetry

    Directory of Open Access Journals (Sweden)

    G. Thepass

    2015-01-01

    Full Text Available Purpose. To determine how different grades of cataract affect sensitivity threshold and saccadic reaction time (SRT in eye movement perimetry (EMP. Methods. In EMP, the visual field is tested by assessing the saccades that a subject makes towards peripheral stimuli using an eye tracker. Forty-eight cataract patients underwent pre- and postoperative EMP examination in both eyes. The subjects had to fix a central stimulus presented on the eye tracker monitor and to look at any detected peripheral stimulus upon its appearance. A multilevel mixed model was used to determine the factors that affected the sensitivity threshold and the SRT as a function of cataract grade. Results. We found no effect of cataract severity (LOCS III grades I through IV on SRT and the sensitivity thresholds. In cataract of LOCS III grade V, however, we found an increase by 27% and 21% (p<0.001, respectively, compared to the SRT and the sensitivity threshold in LOCS III grade I. Eyes that underwent cataract surgery showed no change in mean SRTs and sensitivity thresholds after surgery in LOCS III grade IV and lower. Conclusion. The present study shows that EMP can be readily used in patients with cataract with LOCS III grade IV and below.

  10. A UV pre-ionized dual-wavelength short-pulse high-power CO{sub 2} laser facility for laser particle acceleration research

    Energy Technology Data Exchange (ETDEWEB)

    Ebrahim, N A; Mouris, J F; Davis, R W

    1994-12-01

    In this report we describe the Chalk River dual-wavelength, short-pulse, single-mode, high-power CO{sub 2} laser facility for research in laser particle acceleration and CANDU materials modifications. The facility is designed and built around UV-preionized transversely-excited atmospheric-pressure (TEA) Lumonics CO{sub 2} laser discharge modules. Peak focussed power densities of up to 2 x 10{sup 14} W/cm{sup 2} in 500 ps pulses have been obtained. (author). 10 refs., 9 figs.

  11. Short wavelength infrared optical windows for evaluation of benign and malignant tissues

    Science.gov (United States)

    Sordillo, Diana C.; Sordillo, Laura A.; Sordillo, Peter P.; Shi, Lingyan; Alfano, Robert R.

    2017-04-01

    There are three short wavelength infrared (SWIR) optical windows outside the conventionally used first near-infrared (NIR) window (650 to 950 nm). They occur in the 1000- to 2500-nm range and may be considered second, third, and fourth NIR windows. The second (1100 to 1350 nm) and third windows (1600 to 1870 nm) are now being explored through label-free linear and multiphoton imaging. The fourth window (2100 to 2350 nm) has been mostly ignored because of water absorption and the absence of sensitive detectors and ultrafast lasers. With the advent of new technology, use of window IV is now possible. Absorption and scattering properties of light through breast and prostate cancer, bone, lipids, and intralipid solutions at these windows were investigated. We found that breast and prostate cancer and bone have longer total attenuation lengths at NIR windows III and IV, whereas fatty tissues and intralipid have longest lengths at windows II and III. Since collagen is the major chromophore at 2100 and 2350 nm, window IV could be especially valuable in evaluating cancers and boney tissues, whereas windows II and III may be more useful for tissues with high lipid content. SWIR windows may be utilized as additional optical tools for the evaluation of collagen in tissues.

  12. Action spectrum for photobleaching of human lenses by short wavelength visible irradiation

    DEFF Research Database (Denmark)

    Kessel, Line; Larsen, Michael

    2015-01-01

    transmission with increasing laser irradiation. CONCLUSIONS: For a 75 year old lens an effect corresponding to elimination of 15 years or more of optical ageing was obtained. This study of the spectral characteristics and intensity needed to bleach the human lens with single-photon laser effects found...... an action-spectrum peak at 420 nm tailing gradually off toward longer wavelengths and more steeply toward shorter wavelengths. The results may be used to guide experiments with two-photon bleaching....

  13. Introduction: a short-wavelength-FEL/storage-ring complex

    International Nuclear Information System (INIS)

    Sessler, A.M.

    1984-01-01

    We believe that, in view of the present state of FEL understanding, it is now proper to construct a research facility devoted to the use of coherent radiation and the advancement of FEL physics technology at wavelengths shorter than 1000 A. We show a possible layout of such a facility, which will be referred to as a Coherent xuv Facility (CXF), where research can be conducted on several techniques for generating coherent radiation. Undulators are already well understood and will generate broadly tunable, spatially coherent radiation of bandwidth lambda /Δlambda approx. = 10 2 . A crossed undulator system will extend the undulator capability to include variable polarization. For full coherence, in spatial as well as in longitudinal directions, it is necessary to induce and exploit density modulation in electron beams, as is the case in the transverse optical klystrons (TOKs) and FELs. In TOKs, coherent radiation is generated at harmonics of an input laser frequency, with the electron beam playing the role of a nonlinear medium. Ultimately, FELS would deliver intense, tunable x rays and vuv radiation of extremely narrow spectral width. There are two possible routes to an FEL, one based on feedback by end mirrors, the other based on development of a high-gain, single-pass device. It can be seen, from this paper, that the photon flux increases monotonically, or the wavelength decreases monotonically, as one goes through (1) undulator radiation, (2) TOK radiation, (3) FEL oscillator radiation, to (4) FEL single-pass radiation. Each of these will demand considerable quality development effort. Each will result in photon fluxes of increased value to the users

  14. Radiative flux calculations at UV and visible wavelengths

    International Nuclear Information System (INIS)

    Grossman, A.S.; Grant, K.E.; Wuebbles, D.J.

    1993-10-01

    A radiative transfer model to calculate the short wavelength fluxes at altitudes between 0 and 80 km has been developed at LLNL. The wavelength range extends from 175--735 nm. This spectral range covers the UV-B wavelength region, 250--350 nm, with sufficient resolution to allow comparison of UV-B measurements with theoretical predictions. Validation studies for the model have been made for both UV-B ground radiation calculations and tropospheric solar radiative forcing calculations for various ozone distributions. These studies indicate that the model produces results which agree well with respect to existing UV calculations from other published models

  15. Correlated evolution of short wavelength sensitive photoreceptor sensitivity and color pattern in Lake Malawi cichlids

    Directory of Open Access Journals (Sweden)

    Michael J. Pauers

    2016-02-01

    Full Text Available For evolutionary ecologists, the holy grail of visual ecology is to establish an unambiguous link between photoreceptor sensitivity, the spectral environment, and the perception of specific visual stimuli (e.g., mates, food, predators, etc.. Due to the bright nuptial colors of the males, and the role female mate choice plays in their evolution, the haplochromine cichlid fishes of the African great lakes are favorite research subjects for such investigations. Despite this attention, current evidence is equivocal; while distinct correlations among photoreceptor sensitivity, photic environment, and male coloration exist in Lake Victorian haplochromines, attempts to find such correlations in Lake Malawian cichlids have failed. Lake Malawi haplochromines have a wide variability in their short-wavelength-sensitive photoreceptors, especially compared to their mid- and long-wavelength-sensitive photoreceptors; these cichlids also vary in the degree to which they express one of three basic color patterns (vertical bars, horizontal stripes, and solid patches of colors, each of which is likely used in a different form of communication. Thus, we hypothesize that, in these fishes, spectral sensitivity and color pattern have evolved in a correlated fashion to maximize visual communication; specifically, ultraviolet sensitivity should be found in vertically-barred species to promote ‘private’ communication, while striped species should be less likely to have ultraviolet sensitivity, since their color pattern carries ‘public’ information. Using phylogenetic independent contrasts, we found that barred species had strong sensitivity to ultraviolet wavelengths, but that striped species typically lacked sensitivity to ultraviolet light. Further, the only variable, even when environmental variables were simultaneously considered, that could predict ultraviolet sensitivity was color pattern. We also found that, using models of correlated evolution, color

  16. Single Mode Fiber Optic Transceiver Using Short Wavelength Active Devices In Long Wavelength Fiber

    Science.gov (United States)

    Gillham, Frederick J.; Campbell, Daniel R.; Corke, Michael; Stowe, David W.

    1990-01-01

    Presently, single mode optical fiber technology is being utilized in systems to supply telephone service to the subscriber. However, in an attempt to be competitive with copper based systems, there are many development programs underway to determine the most cost effective solution while still providing a service that will either satisfy or be upgradeable to satisfy the demands of the consumer for the next 10 to 20 years. One such approach is to combine low cost laser transmitters and silicon receivers, which have been developed for the "compact disc" industry, with fiber that operates in the single mode regime at 1300 nm. In this paper, an optical transceiver will be presented, consisting of a compact disc laser, a silicon detector and a single mode coupler at 1300 nm. A possible system layout is presented which operates at 780 nm bi-directionally for POTS and upgradeable to 1300 nm for video services. There are several important design criteria that have to be considered in the development of such a system which will be addressed. These include: 1. Optimization of coupled power from laser to fiber while maintaining stable launched conditions over a wide range of environmental conditions. 2. Consideration of the multimode operation of the 1300 nm single mode fiber while operating in the 780 nm wavelength region. 3. Development of a low cost pseudo-wavelength division multiplexer for 1300 nm single mode/780 nm multimode operation and a low cost dual mode 50/50, 780 nm splitter using 1300 nm fiber. Details will be given of the design criteria and solution in terms of optimized design. Results of the performance of several prototype devices will be given with indications of the merits of this approach and where further development effort should be applied.

  17. Reducing Short-Wavelength Blue Light in Dry Eye Patients with Unstable Tear Film Improves Performance on Tests of Visual Acuity.

    Science.gov (United States)

    Kaido, Minako; Toda, Ikuko; Oobayashi, Tomoo; Kawashima, Motoko; Katada, Yusaku; Tsubota, Kazuo

    2016-01-01

    To investigate whether suppression of blue light can improve visual function in patients with short tear break up time (BUT) dry eye (DE). Twenty-two patients with short BUT DE (10 men, 12 women; mean age, 32.4 ± 6.4 years; age range, 23-43 years) and 18 healthy controls (10 men, 8 women; mean age, 30.1 ± 7.4 years; age range, 20-49 years) underwent functional visual acuity (VA) examinations with and without wearing eyeglasses with 50% blue light blocked lenses. The functional VA parameters were starting VA, functional VA, and visual maintenance ratio. The baseline mean values (logarithm of the minimum angle of resolution, logMAR) of functional VA and the visual maintenance ratio were significantly worse in the DE patients than in the controls (P 0.05). The DE patients had significant improvement in mean functional VA and visual maintenance ratio while wearing the glasses (P 0.05). Protecting the eyes from short-wavelength blue light may help to ameliorate visual impairment associated with tear instability in patients with DE. This finding represents a new concept, which is that the blue light exposure might be harmful to visual function in patients with short BUT DE.

  18. Reducing Short-Wavelength Blue Light in Dry Eye Patients with Unstable Tear Film Improves Performance on Tests of Visual Acuity.

    Directory of Open Access Journals (Sweden)

    Minako Kaido

    Full Text Available To investigate whether suppression of blue light can improve visual function in patients with short tear break up time (BUT dry eye (DE.Twenty-two patients with short BUT DE (10 men, 12 women; mean age, 32.4 ± 6.4 years; age range, 23-43 years and 18 healthy controls (10 men, 8 women; mean age, 30.1 ± 7.4 years; age range, 20-49 years underwent functional visual acuity (VA examinations with and without wearing eyeglasses with 50% blue light blocked lenses. The functional VA parameters were starting VA, functional VA, and visual maintenance ratio.The baseline mean values (logarithm of the minimum angle of resolution, logMAR of functional VA and the visual maintenance ratio were significantly worse in the DE patients than in the controls (P 0.05. The DE patients had significant improvement in mean functional VA and visual maintenance ratio while wearing the glasses (P 0.05.Protecting the eyes from short-wavelength blue light may help to ameliorate visual impairment associated with tear instability in patients with DE. This finding represents a new concept, which is that the blue light exposure might be harmful to visual function in patients with short BUT DE.

  19. Wavelength dependence of momentum-space images of low-energy electrons generated by short intense laser pulses at high intensities

    International Nuclear Information System (INIS)

    Maharjan, C M; Alnaser, A S; Litvinyuk, I; Ranitovic, P; Cocke, C L

    2006-01-01

    We have measured momentum-space images of low-energy electrons generated by the interaction of short intense laser pulses with argon atoms at high intensities. We have done this over a wavelength range from 400 to 800 nm. The spectra show considerable structure in both the energy and angular distributions of the electrons. Some, but not all, energy features can be identified as multi-photon resonances. The angular structure shows a regularity which transcends the resonant structure and may be due instead to diffraction. The complexity of the results defies easy model-dependent interpretations and invites full solutions to Schroedinger's equation for these systems

  20. Investigation of concept of efficient short wavelength laser. Quarterly progress report, 1 August 1978--31 October 1978

    International Nuclear Information System (INIS)

    Piper, L.G.; Krech, R.H.; Pugh, E.R.; Taylor, R.L.

    1978-01-01

    A concept for the development of an efficient short wavelength laser based on a class of endoergic molecules-azides is being studied. One of these two laser-device experiments involves generating high concentrations of azide radicals in the thermal pyrolysis of solid, ionic azides, with the subsequent excitation of the N 2 (B 3 pi/sub g/) state from azide-radical recombination. Laser action would then take place upon the N 2 (B 3 pi/sub g/ - A 3 Sigma + /sub u/), first-postive transition. The second laser-demonstration experiment involves creating a high density of NCl(b 1 Sigma + ) state by uv photolysis of ClN 3 . In this case laser emission is expected on the NCl(b 1 Sigma + → X 3 Sigma - ) transition at 665 nm

  1. Reactions of N2(A3SIGMA/sub u/+) and candidates for short wavelength lasers, March 1, 1984-February 28, 1985

    International Nuclear Information System (INIS)

    Setser, D.W.

    1987-01-01

    There are several potential schemes for efficiently generating high concentrations of the first electronically excited state of nitrogen, N 2 (A 3 Σ/sub u/ + , 6.2 eV) by either chemical or electrical pumping. The goal of this proposal is to study ways of utilizing the energy of the N 2 (A) molecules for developing efficient, short wavelength gas lasers. Such lasers are of potential interest for laser fusion. The authors report both excitation-transfer and dissociative excitation-transfer reactions of N 2 (A) that yield electronically-excited diatomic molecules as products. 25 refs

  2. The groningen longitudinal glaucoma study III. The predictive value of frequency-doubling perimetry and GDx nerve fibre analyser test results for the development of glaucomatous visual field loss

    NARCIS (Netherlands)

    Heeg, G. P.; Jansonius, N. M.

    Purpose To investigate whether frequency-doubling perimetry (FDT) and nerve fibre analyser (GDx) test results are able to predict glaucomatous visual field loss in glaucoma suspect patients. Methods A large cohort of glaucoma suspect patients (patients with ocular hypertension or a positive family

  3. Measurements of the growth rate of the short wavelength Rayleigh-Taylor instability of foam foil packages driven by a soft x-ray pulse

    International Nuclear Information System (INIS)

    Willi, O.; Pasley, J.; Iwase, A.; Nazarov, W.; Rose, S.J.

    2000-01-01

    The Rayleigh-Taylor instability was studied in the short wavelength regime using single mode targets that were driven by hohlraum radiation allowing the Takabe-Morse roll-over due to ablative stabilisation to be investigated. A temporally shaped soft x-ray drive was generated by focusing one of the PHEBUS laser beams into a gold hohlraum with a maximum radiation temperature of about 120 eV. Thin plastic foils with sinusoidal modulations with wavelengths between 12 and 50 μm, and a perturbation amplitude of about 10% of the wavelength, were used. A low density 50 mg/cc tri-acrylate foam 150 μm in length facing the hohlraum was attached to the modulated foam target. The targets were radiographed face-on at an x-ray energy of about 1.3 keV with a spatial resolution of about 5 μm using a Wolter-like x-ray microscope coupled to an x-ray streak camera with a temporal resolution of 50 ps. The acceleration was obtained from side-on radiography. 2-D hydrodynamic code simulations have been carried out to compare the experimental results with the simulations. (authors)

  4. 100G shortwave wavelength division multiplexing solutions for multimode fiber data links

    DEFF Research Database (Denmark)

    Cimoli, Bruno; Estaran Tolosa, Jose Manuel; Rodes Lopez, Guillermo Arturo

    2016-01-01

    We investigate an alternative 100G solution for optical short-range data center links. The presented solution adopts wavelength division multiplexing technology to transmit four channels of 25G over a multimode fiber. A comparative performance analysis of the wavelength-grid selection for the wav...

  5. New Insight into Short-Wavelength Solar Wind Fluctuations from Vlasov Theory

    Science.gov (United States)

    Sahraoui, Fouad; Belmont, G.; Goldstein, M. L.

    2012-01-01

    The nature of solar wind (SW) turbulence below the proton gyroscale is a topic that is being investigated extensively nowadays, both theoretically and observationally. Although recent observations gave evidence of the dominance of kinetic Alfven waves (KAWs) at sub-ion scales with omega omega (sub ci)) is more relevant. Here, we study key properties of the short-wavelength plasma modes under limited, but realistic, SW conditions, Typically Beta(sub i) approx. > Beta (sub e) 1 and for high oblique angles of propagation 80 deg theory, we discuss the relevance of each plasma mode (fast, Bernstein, KAW, whistler) in carrying the energy cascade down to electron scales. We show, in particular, that the shear Alfven mode (known in the magnetohydrodynamic limit) extends at scales kappa rho (sub i) approx. > 1 to frequencies either larger or smaller than omega (sub ci), depending on the anisotropy kappa (parallel )/ kappa(perpendicular). This extension into small scales is more readily called whistler (omega > omega (sub ci)) or KAW (omega < omega (sub ci)) although the mode is essentially the same. This contrasts with the well-accepted idea that the whistler branch always develops as a continuation at high frequencies of the fast magnetosonic mode. We show, furthermore, that the whistler branch is more damped than the KAW one, which makes the latter the more relevant candidate to carry the energy cascade down to electron scales. We discuss how these new findings may facilitate resolution of the controversy concerning the nature of the small-scale turbulence, and we discuss the implications for present and future spacecraft wave measurements in the SW.

  6. Investigation of concept of efficient short wavelength laser. Quarterly progress report, 1 August 1978--31 October 1978

    Energy Technology Data Exchange (ETDEWEB)

    Piper, L.G.; Krech, R.H.; Pugh, E.R.; Taylor, R.L.

    1978-12-01

    A concept for the development of an efficient short wavelength laser based on a class of endoergic molecules-azides is being studied. One of these two laser-device experiments involves generating high concentrations of azide radicals in the thermal pyrolysis of solid, ionic azides, with the subsequent excitation of the N/sub 2/(B/sup 3/pi/sub g/) state from azide-radical recombination. Laser action would then take place upon the N/sub 2/(B/sup 3/pi/sub g/ - A/sup 3/Sigma/sup +//sub u/), first-postive transition. The second laser-demonstration experiment involves creating a high density of NCl(b/sup 1/Sigma/sup +/) state by uv photolysis of ClN/sub 3/. In this case laser emission is expected on the NCl(b/sup 1/Sigma/sup +/ ..-->.. X/sup 3/Sigma/sup -/) transition at 665 nm.

  7. Investigation of concept of efficient short wavelength laser. Quarterly progress report, 1 November 1978-31 January 1979

    Energy Technology Data Exchange (ETDEWEB)

    Krech, R.H.; Piper, L.G.; Pugh, E.R.; Taylor, R.L.

    1979-03-01

    A concept for the development of an efficient short wavelength laser based on a class of endoergic molecules-azides is being investigated. The first of two laser-device experiments involves generating high concentrations of azide radicals in the thermal pyrolysis of solid, ionic azides, with the subsequent excitation of the N/sub 2/(B/sup 3/..pi../sub g/) state from azide-radical recombination. Laser action would then take place upon the N/sub 2/(B/sup 3/..pi../sub g/-A/sup 3/..sigma../sup +//sub u/), first-positive transition. The second laser-demonstration experiment involves creating a high density of NCl(b/sup 1/..sigma../sup +/) state by uv photolysis of ClN/sub 3/. In this case laser emission is expected on the NCl(b/sup 1/..sigma../sup +/..-->..X/sup 3/..sigma../sup -/) transition at 665 nm.

  8. Reactions of N2(A3Σ/sub u/+) and candidates for short wavelength lasers

    International Nuclear Information System (INIS)

    Setser, D.W.

    1987-01-01

    This proposal is a request for a one year renewal of a contract with the Univ. of California (Lawrence Livermore Laboratory). The proposed experiments are directed towards investigation of possible short-wavelength laser candidate molecules that can be pumped via excitation-transfer reactions with N 2 (A 3 Σ/sub u/ + ) molecules. We will continue our flowing-afterglow experiments to characterize the excitation-transfer collisions between N 2 (A) and promising acceptor diatomic molecules (radicals). We also will extend the studies to include excitation-transfer to Cd and to S atoms. For some chemical systems, a pulsed N 2 (A) source would be very convenient for kinetic measurements and we propose to develop a pulsed N 2 (A) source. During the first year, we have shown that the excitation-transfer reaction between N 2 (A) and SO(X) provides a possible laser candidate. Therefore, we propose to start a program to study the quenching and relaxation kinetics of the SO(A 3 PI) molecule, using pulsed laser excitation techniques to generate specific levels of SO(A 3 PI)

  9. Solutions for ultra-high speed optical wavelength conversion and clock recovery

    DEFF Research Database (Denmark)

    Oxenløwe, Leif Katsuo; Galili, Michael; Mulvad, Hans Christian Hansen

    2006-01-01

    This paper reports on our recent advances in ultra-fast optical communications relying on ultra-short pulses densely stacked in ultra-high bit rate serial data signals at a single wavelength. The paper describes details in solutions for the network functionalities of wavelength conversion and clock...... recovery at bit rates up to 320 Gb/s...

  10. Does one hour of bright or short-wavelength filtered tablet screenlight have a meaningful effect on adolescents' pre-bedtime alertness, sleep, and daytime functioning?

    Science.gov (United States)

    Heath, Melanie; Sutherland, Cate; Bartel, Kate; Gradisar, Michael; Williamson, Paul; Lovato, Nicole; Micic, Gorica

    2014-05-01

    Electronic media use is prevalent among adolescent populations, as is the frequency of sleeplessness. One mechanism proposed for technology affecting adolescents' sleep is the alerting effects from bright screens. Two explanations are provided. First, screens emit significant amounts of short-wavelength light (i.e. blue), which produces acute alertness and alters sleep timing. Second, later chronotypes are hypothesised to be hypersensitive to evening light. This study analysed the pre-sleep alertness (GO/NOGO task speed, accuracy; subjective sleepiness), sleep (sleep diary, polysomnography), and morning functioning of 16 healthy adolescents (M = 17.4 ± 1.9 yrs, 56% f) who used a bright tablet screen (80 lux), dim screen (1 lux) and a filtered short-wavelength screen (f.lux; 50 lux) for 1 hr before their usual bedtime in a within-subjects protocol. Chronotype was analysed as a continuous between-subjects factor; however, no significant interactions occurred. Significant effects occurred between bright and dim screens for GO/NOGO speed and accuracy. However, the magnitude of these differences was small (e.g. GO/NOGO speed = 23 ms, accuracy = 13%), suggesting minimal clinical significance. No significant effects were found for sleep onset latency, slow-rolling eye movements, or the number of SWS and REM minutes in the first two sleep cycles. Future independent studies are needed to test short (1 hr) vs longer (>2 hrs) screen usage to provide evidence for safe-to-harmful levels of screenlight exposure before adolescents' usual bedtime.

  11. Short-wavelength infrared imaging using low dark current InGaAs detector arrays and vertical-cavity surface-emitting laser illuminators

    Science.gov (United States)

    Macdougal, Michael; Geske, Jon; Wang, Chad; Follman, David

    2011-06-01

    We describe the factors that go into the component choices for a short wavelength IR (SWIR) imager, which include the SWIR sensor, the lens, and the illuminator. We have shown the factors for reducing dark current, and shown that we can achieve well below 1.5 nA/cm2 for 15 μm devices at 7 °C. In addition, we have mated our InGaAs detector arrays to 640×512 readout integrated integrated circuits to make focal plane arrays (FPAs). The resulting FPAs are capable of imaging photon fluxes with wavelengths between 1 and 1.6 μm at low light levels. The dark current associated with these FPAs is extremely low, exhibiting a mean dark current density of 0.26 nA/cm2 at 0 °C. Noise due to the readout can be reduced from 95 to 57 electrons by using off-chip correlated double sampling. In addition, Aerius has developed laser arrays that provide flat illumination in scenes that are normally light-starved. The illuminators have 40% wall-plug efficiency and provide low-speckle illumination, and provide artifact-free imagery versus conventional laser illuminators.

  12. Comparison of different wavelength pump sources for Tm subnanosecond amplifier

    Science.gov (United States)

    Cserteg, Andras; Guillemet, Sébastien; Hernandez, Yves; Giannone, Domenico

    2012-06-01

    We report here a comparison of different pumping wavelengths for short pulse Thulium fibre amplifiers. We compare the results in terms of efficiency and required fibre length. As we operate the laser in the sub-nanosecond regime, the fibre length is a critical parameter regarding non linear effects. With 793 nm clad-pumping, a 4 m long active fibre was necessary, leading to strong spectral deformation through Self Phase Modulation (SPM). Core-pumping scheme was then more in-depth investigated with several wavelengths tested. Good results with Erbium and Raman shifted pumping sources were obtained, with very short fibre length, aiming to reach a few micro-joules per pulse without (or with limited) SPM.

  13. Fully-automated identification of fish species based on otolith contour: using short-time Fourier transform and discriminant analysis (STFT-DA).

    Science.gov (United States)

    Salimi, Nima; Loh, Kar Hoe; Kaur Dhillon, Sarinder; Chong, Ving Ching

    2016-01-01

    Background. Fish species may be identified based on their unique otolith shape or contour. Several pattern recognition methods have been proposed to classify fish species through morphological features of the otolith contours. However, there has been no fully-automated species identification model with the accuracy higher than 80%. The purpose of the current study is to develop a fully-automated model, based on the otolith contours, to identify the fish species with the high classification accuracy. Methods. Images of the right sagittal otoliths of 14 fish species from three families namely Sciaenidae, Ariidae, and Engraulidae were used to develop the proposed identification model. Short-time Fourier transform (STFT) was used, for the first time in the area of otolith shape analysis, to extract important features of the otolith contours. Discriminant Analysis (DA), as a classification technique, was used to train and test the model based on the extracted features. Results. Performance of the model was demonstrated using species from three families separately, as well as all species combined. Overall classification accuracy of the model was greater than 90% for all cases. In addition, effects of STFT variables on the performance of the identification model were explored in this study. Conclusions. Short-time Fourier transform could determine important features of the otolith outlines. The fully-automated model proposed in this study (STFT-DA) could predict species of an unknown specimen with acceptable identification accuracy. The model codes can be accessed at http://mybiodiversityontologies.um.edu.my/Otolith/ and https://peerj.com/preprints/1517/. The current model has flexibility to be used for more species and families in future studies.

  14. Aluminum nitride nanophotonic circuits operating at ultraviolet wavelengths

    Energy Technology Data Exchange (ETDEWEB)

    Stegmaier, M.; Ebert, J.; Pernice, W. H. P., E-mail: wolfram.pernice@kit.edu [Institute of Nanotechnology, Karlsruhe Institute of Technology, 76133 Karlsruhe (Germany); Meckbach, J. M.; Ilin, K.; Siegel, M. [Institute of Micro- und Nanoelectronic Systems, Karlsruhe Institute of Technology, 76187 Karlsruhe (Germany)

    2014-03-03

    Aluminum nitride (AlN) has recently emerged as a promising material for integrated photonics due to a large bandgap and attractive optical properties. Exploiting the wideband transparency, we demonstrate waveguiding in AlN-on-Insulator circuits from near-infrared to ultraviolet wavelengths using nanophotonic components with dimensions down to 40 nm. By measuring the propagation loss over a wide spectral range, we conclude that both scattering and absorption of AlN-intrinsic defects contribute to strong attenuation at short wavelengths, thus providing guidelines for future improvements in thin-film deposition and circuit fabrication.

  15. Dual-wavelength phase-shifting digital holography selectively extracting wavelength information from wavelength-multiplexed holograms.

    Science.gov (United States)

    Tahara, Tatsuki; Mori, Ryota; Kikunaga, Shuhei; Arai, Yasuhiko; Takaki, Yasuhiro

    2015-06-15

    Dual-wavelength phase-shifting digital holography that selectively extracts wavelength information from five wavelength-multiplexed holograms is presented. Specific phase shifts for respective wavelengths are introduced to remove the crosstalk components and extract only the object wave at the desired wavelength from the holograms. Object waves in multiple wavelengths are selectively extracted by utilizing 2π ambiguity and the subtraction procedures based on phase-shifting interferometry. Numerical results show the validity of the proposed technique. The proposed technique is also experimentally demonstrated.

  16. Synthesis of tracers using automated radiochemistry and robotics

    International Nuclear Information System (INIS)

    Dannals, R.F.

    1992-07-01

    Synthesis of high specific activity radiotracers labeled with short-lived positron-emitting radionuclides for positron emission tomography (PET) often requires handling large initial quantities of radioactivity. High specific activities are required when preparing tracers for use in PET studies of neuroreceptors. A fully automated approach for tracer synthesis is highly desirable. This proposal involves the development of a system for the Synthesis of Tracers using Automated Radiochemistry and Robotics (STARR) for this purpose. While the long range objective of the proposed research is the development of a totally automated radiochemistry system for the production of major high specific activity 11 C-radiotracers for use in PET, the specific short range objectives are the automation of 11 C-methyl iodide ( 11 CH 3 I) production via an integrated approach using both radiochemistry modular labstations and robotics, and the extension of this automated capability to the production of several radiotracers for PET (initially, 11 C-methionine, 3-N-[ 11 C-methyl]spiperone, and [ 11 C]-carfentanil)

  17. High accuracy wavelength calibration for a scanning visible spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Scotti, Filippo; Bell, Ronald E. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States)

    2010-10-15

    Spectroscopic applications for plasma velocity measurements often require wavelength accuracies {<=}0.2 A. An automated calibration, which is stable over time and environmental conditions without the need to recalibrate after each grating movement, was developed for a scanning spectrometer to achieve high wavelength accuracy over the visible spectrum. This method fits all relevant spectrometer parameters using multiple calibration spectra. With a stepping-motor controlled sine drive, an accuracy of {approx}0.25 A has been demonstrated. With the addition of a high resolution (0.075 arc sec) optical encoder on the grating stage, greater precision ({approx}0.005 A) is possible, allowing absolute velocity measurements within {approx}0.3 km/s. This level of precision requires monitoring of atmospheric temperature and pressure and of grating bulk temperature to correct for changes in the refractive index of air and the groove density, respectively.

  18. Ultraviolet and short wavelength visible light exposure: why ultraviolet protection alone is not adequate.

    Science.gov (United States)

    Reichow, Alan W; Citek, Karl; Edlich, Richard F

    2006-01-01

    The danger of exposure to ultraviolet (UV) radiation in both the natural environment and artificial occupational settings has long been recognized by national and international standards committees and worker safety agencies. There is an increasing body of literature that suggests that protection from UV exposure is not enough. Unprotected exposure to the short wavelengths of the visible spectrum, termed the "blue light hazard", is gaining acceptance as a true risk to long-term visual health. Global standards and experts in the field are now warning that those individuals who spend considerable time outdoors should seek sun filter eyewear with high impact resistant lenses that provide 100% UV filtration, high levels of blue light filtration, and full visual field lens/frame coverage as provided by high wrap eyewear. The Skin Cancer Foundation has endorsed certain sunglasses as "product[s]...effective [as] UV filter[s] for the eyes and surrounding skin". However, such endorsement does not necessarily mean that the eyewear meets all the protective needs for outdoor use. There are several brands that offer products with such protective characteristics. Performance sun eyewear by Nike Vision, available in both corrective and plano (nonprescription) forms, is one such brand incorporating these protective features.

  19. Wavelength dependence of the linear growth rate of the Es layer instability

    Directory of Open Access Journals (Sweden)

    R. B. Cosgrove

    2007-06-01

    Full Text Available It has recently been shown, by computation of the linear growth rate, that midlatitude sporadic-E (Es layers are subject to a large scale electrodynamic instability. This instability is a logical candidate to explain certain frontal structuring events, and polarization electric fields, which have been observed in Es layers by ionosondes, by coherent scatter radars, and by rockets. However, the original growth rate derivation assumed an infinitely thin Es layer, and therefore did not address the short wavelength cutoff. Also, the same derivation ignored the effects of F region loading, which is a significant wavelength dependent effect. Herein is given a generalized derivation that remedies both these short comings, and thereby allows a computation of the wavelength dependence of the linear growth rate, as well as computations of various threshold conditions. The wavelength dependence of the linear growth rate is compared with observed periodicities, and the role of the zeroth order meridional wind is explored. A three-dimensional paper model is used to explain the instability geometry, which has been defined formally in previous works.

  20. Long-Wavelength Phonon Scattering in Nonpolar Semiconductors

    DEFF Research Database (Denmark)

    Lawætz, Peter

    1969-01-01

    The long-wavelength acoustic- and optical-phonon scattering of carriers in nonpolar semiconductors is considered from a general point of view. The deformation-potential approximation is defined and it is shown that long-range electrostatic forces give a nontrivial correction to the scattering...... of the very-short-range nature of interactions in a covalent semiconductor....

  1. Characterization of Low Noise TES Detectors Fabricated by D-RIE Process for SAFARI Short-Wavelength Band

    Science.gov (United States)

    Khosropanah, P.; Suzuki, T.; Hijmering, R. A.; Ridder, M. L.; Lindeman, M. A.; Gao, J.-R.; Hoevers, H.

    2014-08-01

    SRON is developing TES detectors based on a superconducting Ti/Au bilayer on a suspended SiN membrane for the short-wavelength band of the SAFARI instrument on SPICA mission. We have recently replaced the wet KOH etching of the Si substrate by deep reactive ion etching. The new process enables us to fabricate the detectors on the substrate and release the membrane at the very last step. Therefore the production of SAFARI large arrays (4343) on thin SiN membrane (250 nm) is feasible. It also makes it possible to realize narrow supporting SiN legs of 1 m, which are needed to meet SAFARI NEP requirements. Here we report the current-voltage characteristics, noise performance and impedance measurement of these devices. The measured results are then compared with the distributed leg model that takes into account the thermal fluctuation noise due to the SiN legs. We measured a dark NEP of 0.7 aW/, which is 1.6 times higher than the theoretically expected phonon noise.

  2. Agility of Felix Regarding Wavelength and Micropulse Shape

    NARCIS (Netherlands)

    Bakker, R. J.; van der Geer, C. A. J.; Jaroszynski, D. A.; van der Meer, A. F. G.; Oepts, D.; van Amersfoort, P. W.; Anderegg, V.; van Son, P. C.

    1993-01-01

    The user-facility FELIX employs two FELs together covering the spectral range from 6.5 to 110 mum. Adjustment of the undulator strength permits wavelength tuning over a factor of two within two minutes while continuously providing several kilowatts of output power. As FELIX combines short electron

  3. Does Posterior Capsule Opacification Affect the Results of Diagnostic Technologies to Evaluate the Retina and the Optic Disc?

    Directory of Open Access Journals (Sweden)

    Jose Javier Garcia-Medina

    2015-01-01

    should be set for future comparisons following capsulotomy when using automated perimetry and scanning laser polarimetry. To perform OCT in the presence of PCO, reliable examinations (considering signal strength apparently guarantee that measurements are not influenced by PCO.

  4. The role of hemifield sector analysis in multifocal visual evoked potential objective perimetry in the early detection of glaucomatous visual field defects

    Directory of Open Access Journals (Sweden)

    Mousa MF

    2013-05-01

    Full Text Available Mohammad F Mousa,1 Robert P Cubbidge,2 Fatima Al-Mansouri,1 Abdulbari Bener3,41Department of Ophthalmology, Hamad Medical Corporation, Doha, Qatar; 2School of Life and Health Sciences, Aston University, Birmingham, UK; 3Department of Medical Statistics and Epidemiology, Hamad Medical Corporation, Department of Public Health, Weill Cornell Medical College, Doha, Qatar; 4Department Evidence for Population Health Unit, School of Epidemiology and Health Sciences, University of Manchester, Manchester, UKObjective: The purpose of this study was to examine the effectiveness of a new analysis method of mfVEP objective perimetry in the early detection of glaucomatous visual field defects compared to the gold standard technique.Methods and patients: Three groups were tested in this study; normal controls (38 eyes, glaucoma patients (36 eyes, and glaucoma suspect patients (38 eyes. All subjects underwent two standard 24-2 visual field tests: one with the Humphrey Field Analyzer and a single mfVEP test in one session. Analysis of the mfVEP results was carried out using the new analysis ­protocol: the hemifield sector analysis protocol.Results: Analysis of the mfVEP showed that the signal to noise ratio (SNR difference between superior and inferior hemifields was statistically significant between the three groups (analysis of variance, P < 0.001 with a 95% confidence interval, 2.82, 2.89 for normal group; 2.25, 2.29 for glaucoma suspect group; 1.67, 1.73 for glaucoma group. The difference between superior and inferior hemifield sectors and hemi-rings was statistically significant in 11/11 pair of sectors and hemi-rings in the glaucoma patients group (t-test P < 0.001, statistically significant in 5/11 pairs of sectors and hemi-rings in the glaucoma suspect group (t-test P < 0.01, and only 1/11 pair was statistically significant (t-test P < 0.9. The sensitivity and specificity of the hemifield sector analysis protocol in detecting glaucoma was 97% and 86

  5. Increasing robustness of indirect drive capsule designs against short wavelength hydrodynamic instabilities

    International Nuclear Information System (INIS)

    Haan, S.W.; Herrmann, M.C.; Dittrich, T.R.; Fetterman, A.J.; Marinak, M.M.; Munro, D.H.; Pollaine, S.M.; Salmonson, J.D.; Strobel, G.L.; Suter, L.J.

    2005-01-01

    Targets meant to achieve ignition on the National Ignition Facility (NIF) [J. A. Paisner, J. D. Boyes, S. A. Kumpan, W. H. Lowdermilk, and M. S. Sorem, Laser Focus World 30, 75 (1994)] have been redesigned and their performance simulated. Simulations indicate dramatically reduced growth of short wavelength hydrodynamic instabilities, resulting from two changes in the designs. First, better optimization results from systematic mapping of the ignition target performance over the parameter space of ablator and fuel thickness combinations, using techniques developed by one of us (Herrmann). After the space is mapped with one-dimensional simulations, exploration of it with two-dimensional simulations quantifies the dependence of instability growth on target dimensions. Low modes and high modes grow differently for different designs, allowing a trade-off of the two regimes of growth. Significant improvement in high-mode stability can be achieved, relative to previous designs, with only insignificant increase in low-mode growth. This procedure produces capsule designs that, in simulations, tolerate several times the surface roughness that could be tolerated by capsules optimized by older more heuristic techniques. Another significant reduction in instability growth, by another factor of several, is achieved with ablators with radially varying dopant. In this type of capsule the mid-Z dopant, which is needed in the ablator to minimize x-ray preheat at the ablator-ice interface, is optimally positioned within the ablator. A fabrication scenario for graded dopants already exists, using sputter coating to fabricate the ablator shell. We describe the systematics of these advances in capsule design, discuss the basis behind their improved performance, and summarize how this is affecting our plans for NIF ignition

  6. Correlation between Macular Thickness and Visual Field in Early Open Angle Glaucoma: A Cross-Sectional Study.

    Science.gov (United States)

    Fallahi Motlagh, Behzad; Sadeghi, Ali

    2017-01-01

    The aim of this study was to correlate macular thickness and visual field parameters in early glaucoma. A total of 104 eyes affected with early glaucoma were examined in a cross-sectional, prospective study. Visual field testing using both standard automated perimetry (SAP) and shortwave automated perimetry (SWAP) was performed. Global visual field parameters, including mean deviation (MD) and pattern standard deviation (PSD), were recorded and correlated with spectral domain optical coherence tomography (SD-OCT)-measured macular thickness and asymmetry. Average macular thickness correlated significantly with all measures of visual field including MD-SWAP (r = 0.42), MD-SAP (r = 0.41), PSD-SWAP (r = -0.23), and PSD-SAP (r = -0.21), with P-values field parameters in early glaucoma. The results of this study should make macular thickness measurements even more meaningful to glaucoma specialists.

  7. [The effect of parenteral citicoline on visual functions and life quality of patients with primary open-angle glaucoma].

    Science.gov (United States)

    Frolov, M A; Gonchar, P A; Barashkov, V I; Kumar, V; Morozova, N S; Frolov, A M; Kazakova, K A

    2011-01-01

    The effect of nootropic drug citicoline on visual functions, perimetric indexes of static automated perimetry, morphometric characteristics of retinal tomography and life quality of patients with primary open-angle glaucoma (POAG) stage I-III and normalized intraocular pressure (IOP) was studied. 40 patients aged 46-78 years old with POAG stage I-III and normalized IOP were treated with citicoline. Among them there were 24 female and 16 male. The patients were divided into 2 equal groups--experimental and control. Patients of both groups were treated with intravenous citicoline for 10 days. The dose of citicoline in experimental group was 1000 mg/day, in control--500 mg/day. After treatment in both groups visual functions, perimetric indexes of static automated perimetry, morphometric characteristics of retinal tomography and life quality showed improvement. Citicoline has significant neuroprotective effect preventing apoptosis.

  8. Use of europium ions for SAD phasing of lysozyme at the Cu Kα wavelength

    International Nuclear Information System (INIS)

    Vijayakumar, Balakrishnan; Velmurugan, Devadasan

    2012-01-01

    Europium(III) ions bound to the surface of hen egg-white lysozyme were found to exhibit good anomalous signal facilitating SAD phasing using laboratory-source data and automated model building. The europium ion-binding sites were observed up to the 15σ level. Europium is shown to be a good anomalous scatterer in SAD phasing for solving the structure of biological macromolecules. The large value of the anomalous contribution of europium, f′′ = 11.17 e − , at the Cu Kα wavelength is an advantage in de novo phasing and automated model building. Tetragonal crystals of hen egg-white lysozyme (HEWL) incorporating europium(III) chloride (50 mM) were obtained which diffracted to a resolution of 2.3 Å at a wavelength of 1.54 Å (Cu Kα). The master data set (360° frames) was split and analyzed for anomalous signal-to-noise ratio, multiplicity, completeness, SAD phasing and automated building. The structure solution and model building of the split data sets were carried out using phenix.autosol and phenix.autobuild. The contributions of the Eu ions to SAD phasing using in-house data collection are discussed. This study revealed successful lysozyme phasing by SAD using laboratory-source data involving Eu ions, which are mainly coordinated by the side chains of Asn46, Asp52 and Asp101 together with some water molecules

  9. Is there an unknown risk for short-wavelength visible laser radiation?

    Energy Technology Data Exchange (ETDEWEB)

    Reidenbach, Hans-Dieter; Beckmann, Dirk; Al Ghouz, Imene; Dollinger, Klaus [Fachhochschule Koeln (Germany). Forschungsbereich Medizintechnik und Nichtionisierende Strahlung; Ott, Guenter [Bundesanstalt fuer Arbeitsschutz und Arbeitsmedizin (BAuA), Dortmund (Germany); Brose, Martin [Berufsgenossenschaft Energie Textil Elektro Medienerzeugnisse (BG ETEM), Koeln (Germany)

    2013-09-01

    A specially designed test apparatus was used in the investigation on temporary blinding. During provisional tests, exposure had been carried out with different wavelengths, power settings and exposure durations. One subject familiar to the effects of temporary blinding experienced an unusual effect, which lasted a long period of time. Concerning that this effect is not known enough to be considered in safety regulations, make it important to publish this report. (orig.)

  10. Cycle 24 COS FUV Internal/External Wavelength Scale Monitor

    Science.gov (United States)

    Fischer, William J.

    2018-02-01

    We report on the monitoring of the COS FUV wavelength scale zero-points during Cycle 24 in program 14855. Select cenwaves were monitored for all FUV gratings at Lifetime Position 3. The target and cenwaves have remained the same since Cycle 21, with a change only to the target acquisition sequence. All measured offsets are within the error goals, although the G140L cenwaves show offsets at the short-wavelength end of segment A that are approaching the tolerance. This behavior will be closely monitored in subsequent iterations of the program.

  11. Photoreceptor atrophy in acute zonal occult outer retinopathy

    DEFF Research Database (Denmark)

    Zibrandtsen, N.; Munch, I.C.; Klemp, K.

    2006-01-01

    Purpose: To assess retinal morphology in acute zonal occult outer retinopathy (AZOOR). Methods: Three patients with a normal ophthalmoscopic fundus appearance, a history of photopsia, and visual field loss compatible with AZOOR were examined using optical coherence tomography, automated perimetry...

  12. Artificial light pollution: Shifting spectral wavelengths to mitigate physiological and health consequences in a nocturnal marsupial mammal.

    Science.gov (United States)

    Dimovski, Alicia M; Robert, Kylie A

    2018-05-02

    The focus of sustainable lighting tends to be on reduced CO 2 emissions and cost savings, but not on the wider environmental effects. Ironically, the introduction of energy-efficient lighting, such as light emitting diodes (LEDs), may be having a great impact on the health of wildlife. These white LEDs are generated with a high content of short-wavelength 'blue' light. While light of any kind can suppress melatonin and the physiological processes it regulates, these short wavelengths are potent suppressors of melatonin. Here, we manipulated the spectral composition of LED lights and tested their capacity to mitigate the physiological and health consequences associated with their use. We experimentally investigated the impact of white LEDs (peak wavelength 448 nm; mean irradiance 2.87 W/m 2 ), long-wavelength shifted amber LEDs (peak wavelength 605 nm; mean irradiance 2.00 W/m 2 ), and no lighting (irradiance from sky glow light treatments. White LED exposed wallabies had significantly suppressed nocturnal melatonin compared to no light and amber LED exposed wallabies, while there was no difference in lipid peroxidation. Antioxidant capacity declined from baseline to week 10 under all treatments. These results provide further evidence that short-wavelength light at night is a potent suppressor of nocturnal melatonin. Importantly, we also illustrate that shifting the spectral output to longer wavelengths could mitigate these negative physiological impacts. © 2018 Wiley Periodicals, Inc.

  13. [Fundus autofluorescence in patients with inherited retinal diseases : Patterns of fluorescence at two different wavelengths.

    NARCIS (Netherlands)

    Theelen, T.; Boon, C.J.F.; Klevering, B.J.; Hoyng, C.B.

    2008-01-01

    BACKGROUND: Fundus autofluorescence (FAF) may be excited and measured at different wavelengths. In the present study we compared short wavelength and near-infrared FAF patterns of retinal dystrophies. METHODS: We analysed both eyes of 108 patients with diverse retinal dystrophies. Besides colour

  14. Stability of short-axial-wavelength internal kink modes of an anisotropic plasma

    Science.gov (United States)

    Faghihi, M.; Scheffel, J.

    1987-12-01

    The double adiabatic equations are used to study the stability of a cylindrical Z-pinch with respect to small axial wavelength, internal kink (m ≥ 1) modes. It is found that marginally (ideally) unstable, isotropic equilibria are stabilized. Also, constant-current-density equilibria can be stabilized for P > P and large β

  15. Expression and Evolution of Short Wavelength Sensitive Opsins in Colugos: A Nocturnal Lineage That Informs Debate on Primate Origins.

    Science.gov (United States)

    Moritz, Gillian L; Lim, Norman T-L; Neitz, Maureen; Peichl, Leo; Dominy, Nathaniel J

    2013-01-01

    A nocturnal activity pattern is central to almost all hypotheses on the adaptive origins of primates. This enduring view has been challenged in recent years on the basis of variation in the opsin genes of nocturnal primates. A correspondence between the opsin genes and activity patterns of species in Euarchonta-the superordinal group that includes the orders Primates, Dermoptera (colugos), and Scandentia (treeshrews)-could prove instructive, yet the basic biology of the dermopteran visual system is practically unknown. Here we show that the eye of the Sunda colugo ( Galeopterus variegatus ) lacks a tapetum lucidum and has an avascular retina, and we report on the expression and spectral sensitivity of cone photopigments. We found that Sunda colugos have intact short wavelength sensitive (S-) and long wavelength sensitive (L-) opsin genes, and that both opsins are expressed in cone photoreceptors of the retina. The inferred peak spectral sensitivities are 451 and 562 nm, respectively. In line with adaptation to nocturnal vision, cone densities are low. Surprisingly, a majority of S-cones coexpress some L-opsin. We also show that the ratio of rates of nonsynonymous to synonymous substitutions of exon 1 of the S-opsin gene is indicative of purifying selection. Taken together, our results suggest that natural selection has favored a functional S-opsin in a nocturnal lineage for at least 45 million years. Accordingly, a nocturnal activity pattern remains the most likely ancestral character state of euprimates.

  16. AlGaN-based laser diodes for the short-wavelength ultraviolet region

    International Nuclear Information System (INIS)

    Yoshida, Harumasa; Kuwabara, Masakazu; Yamashita, Yoji; Takagi, Yasufumi; Uchiyama, Kazuya; Kan, Hirofumi

    2009-01-01

    We have demonstrated the room-temperature operation of GaN/AlGaN and indium-free AlGaN multiple-quantum-well (MQW) laser diodes under the pulsed-current mode. We have successfully grown low-dislocation-density AlGaN films with AlN mole fractions of 20 and 30% on sapphire substrates using the hetero-facet-controlled epitaxial lateral overgrowth (hetero-FACELO) method. GaN/AlGaN and AlGaN MQW laser diodes have been fabricated on the low-dislocation-density Al 0.2 Ga 0.8 N and Al 0.3 Ga 0.7 N films, respectively. The GaN/AlGaN MQW laser diodes lased at a peak wavelength ranging between 359.6 and 354.4 nm. A threshold current density of 8 kA cm -2 , an output power as high as 80 mW and a differential external quantum efficiency (DEQE) of 17.4% have been achieved. The AlGaN MQW laser diodes lased at a peak wavelength down to 336.0 nm far beyond the GaN band gap. For the GaN/AlGaN MQW laser diodes, the modal gain coefficient and the optical internal loss are estimated to be 4.7±0.6 cm kA -1 and 10.6±2.7 cm -1 , respectively. We have observed that the characteristic temperature T 0 ranges from 132 to 89 K and DEQE shows an almost stable tendency with increase of temperature. A temperature coefficient of 0.049 nm K -1 is also found for the GaN/AlGaN MQW laser diode. The results for the AlGaN-based laser diodes grown on high-quality AlGaN films presented here will be essential for the future development of laser diodes emitting much shorter wavelengths.

  17. Tailoring Chirped Moiré Fiber Bragg Gratings for Wavelength-Division-Multiplexing and Optical Code-Division Multiple-Access Applications

    Science.gov (United States)

    Chen, Lawrence R.; Smith, Peter W. E.

    The design and fabrication of chirped Moiré fiber Bragg gratings (CMGs) are presented, which can be used in either (1) transmission as passband filters for providing wavelength selectivity in wavelength-division-multiplexed (WDM) systems or (2) reflection as encoding/decoding elements to decompose short broadband pulses in both wavelength and time in order to implement an optical code-division multiple-access (OCDMA) system. In transmission, the fabricated CMGs have single or multiple flattened passbands ( 12 dB isolation and near constant in-band group delay. It is shown that these filters do not produce any measurable dispersion-induced power penalties when used to provide wavelength selectivity in 2.5 Gbit/s systems. It is also demonstrated how CMGs can be used in reflection to encode/decode short pulses from a wavelength-tunable mode-locked Er-doped fiber laser.

  18. Stability of short-axial-wavelength internal kink modes of an anisotropic plasma

    International Nuclear Information System (INIS)

    Faghihi, M.; Schefffel, J.

    1987-01-01

    The double adiabatic equations are used to study the stability of a cylindrical Z-pinch with respect to small axial wavelength, internal kink (m ≥ 1) modes. It is found that marginally (ideally) unstable, isotropic equilibria are stabilized. Also, constant-current-density equilibria can be stabilized for Psub(perpendicular) > Psub(parallel) and large βsub(perpendicular). (author)

  19. Automation of radioimmunoassays

    International Nuclear Information System (INIS)

    Goldie, D.J.; West, P.M.; Ismail, A.A.A.

    1979-01-01

    A short account is given of recent developments in automation of the RIA technique. Difficulties encountered in the incubation, separation and quantitation steps are summarized. Published references are given to a number of systems, both discrete and continuous flow, and details are given of a system developed by the present authors. (U.K.)

  20. Why do drivers maintain short headways in fog? A driving-simulator study evaluating feeling of risk and lateral control during automated and manual car following.

    Science.gov (United States)

    Saffarian, M; Happee, R; Winter, J C F de

    2012-01-01

    Drivers in fog tend to maintain short headways, but the reasons behind this phenomenon are not well understood. This study evaluated the effect of headway on lateral control and feeling of risk in both foggy and clear conditions. Twenty-seven participants completed four sessions in a driving simulator: clear automated (CA), clear manual (CM), fog automated (FA) and fog manual (FM). In CM and FM, the drivers used the steering wheel, throttle and brake pedals. In CA and FA, a controller regulated the distance to the lead car, and the driver only had to steer. Drivers indicated how much risk they felt on a touchscreen. Consistent with our hypothesis, feeling of risk and steering activity were elevated when the lead car was not visible. These results might explain why drivers adopt short headways in fog. Practitioner Summary: Fog poses a serious road safety hazard. Our driving-simulator study provides the first experimental evidence to explain the role of risk-feeling and lateral control in headway reduction. These results are valuable for devising effective driver assistance and support systems.

  1. Role of frequency doubling technology perimetry in screening of diabetic retinopathy.

    Directory of Open Access Journals (Sweden)

    Parikh Rajul

    2006-01-01

    Full Text Available Purpose: To study the ability of frequency-doubling technology perimetry (FDT to detect sight-threatening diabetic retinopathy. Method: Fifty-eight eyes of fifty-eight patients with established diagnosis of diabetes mellitus with diabetic retinopathy, fifty-five eyes of fifty-five diabetic patients without retinopathy, and forty-one eyes of forty-one normals underwent FDT and dilated stereo-biomicroscopic fundus examination. The sensitivity and specificity of FDT in identification of "sight-threatening retinopathy" (severe and very severe nonproliferative diabetic retinopathy and proliferative diabetic retinopathy and clinically significant macular edema (CSME were determined. Results: For the detection of sight-threatening retinopathy, two abnormal adjacent points depressed to any level on the 20-1 screening program had a sensitivity of 90.5% and specificity of 97.6%. At (assuming a 10% prevalence of sight-threatening retinopathy in a diabetic clinic, two abnormal adjacent points anywhere in the field depressed to any level has a positive predictive value (PPV of 48% with a negative predictive value of 98.8%. Sensitivity and specificity for the detection of CSME was poor. Conclusions: The 20-1 screening program of the FDT is useful in the detection of sight-threatening diabetic retinopathy (PPV 48%. A normal 20-1 test rules out sight-threatening retinopathy. FDT was not useful in the detection of CSME.

  2. Stability of short-axial-wavelength internal kink modes of an anisotropic plasma

    Energy Technology Data Exchange (ETDEWEB)

    Faghihi, M.; Schefffel, J.

    1987-12-01

    The double adiabatic equations are used to study the stability of a cylindrical Z-pinch with respect to small axial wavelength, internal kink (m greater than or equal to 1) modes. It is found that marginally (ideally) unstable, isotropic equilibria are stabilized. Also, constant-current-density equilibria can be stabilized for Psub(perpendicular) > Psub(parallel) and large ..beta..sub(perpendicular).

  3. Optogalvanic wavelength calibration for laser monitoring of reactive atmospheric species

    Science.gov (United States)

    Webster, C. R.

    1982-01-01

    Laser-based techniques have been successfully employed for monitoring atmospheric species of importance to stratospheric ozone chemistry or tropospheric air quality control. When spectroscopic methods using tunable lasers are used, a simultaneously recorded reference spectrum is required for wavelength calibration. For stable species this is readily achieved by incorporating into the sensing instrument a reference cell containing the species to be monitored. However, when the species of interest is short-lived, this approach is unsuitable. It is proposed that wavelength calibration for short-lived species may be achieved by generating the species of interest in an electrical or RF discharge and using optogalvanic detection as a simple, sensitive, and reliable means of recording calibration spectra. The wide applicability of this method is emphasized. Ultraviolet, visible, or infrared lasers, either CW or pulsed, may be used in aircraft, balloon, or shuttle experiments for sensing atoms, molecules, radicals, or ions.

  4. Short-wavelength electrostatic waves in the earth's magnetosheath

    International Nuclear Information System (INIS)

    Gallagher, D.L.

    1985-01-01

    Recent observations with the ISEE 1 spacecraft have found electric field emissions in the dayside magnetosheath whose frequency spectrum is modulated at twice the spacecraft spin period. The upper frequency cutoff in the frequency-time spectrum of the emission has a characteristic parabola shape or ''festoon'' shape. The low-frequency cutoff ranges from 100 to 400 Hz, while the high-frequency limit ranges from about 1 to 4 kHz. The bandwidth is found to minimize for antenna orientations parallel to the wave vectors. The wave vector does not appear to be related to the local magnetic field, the plasma flow velocity, or the spacecraft-sun directions. The spacecraft observed frequency spectrum results from the spacecraft antenna response to the Doppler-shifted wave vector spectrum which exists in the plasma. Imposed constraints on the plasma rest frame wave vectors and frequencies indicate that emissions occur within the frequency range from about 150 Hz to 1 kHz, with wavelengths between about 40 and 600 m. These constraints strongly suggest that the festoon-shaped emissions are ion-acoustic waves. The small group velocity and k direction of the ion-acoustic mode are consistent with wave generation upstream at the bow shock and convection downstream to locations within the outer dayside magnetosheath

  5. Short wavelength electrostatic waves in the earth's magnetosheath

    International Nuclear Information System (INIS)

    Gallagher, D.L.

    1982-01-01

    Recent observations with the ISEE-1 spacecraft have found electric field emissions in the dayside magnetosheath whose frequency spectrum is modulated at twice the spacecraft spin period. The upper frequency cutoff in the frequency-time spectrum of the emissions has a characteristic parabola shape or ''festoon'' shape. The low frequency cutoff ranges from 100 Hz to 400 Hz, while the high frequency limit ranges from about 1kHz to 4kHz. The bandwidth is found to minimize for antenna orientations parallel to these wave number vectors, requiring the confinement of those vectors to a plane which contains the geocentric solar eclilptic coordinate z-axis. The spacecraft observed frequency spectrum results from the spacecraft antenna response to the Doppler shifted wave vector spectrum which exists in the plasma. Imposed constraints on the plasma rest-frame wave vectors and frequencies indicate that the emissions occur within the frequency range from about 150 Hz to 1 kHz, with wavelengths between about 30 meters and 600 meters. These constraints strongly suggest that the festoon-shaped emissions are ion-acoustic waves. The small group velocity and k vector direction of the ion-acoustic mode are consistent with wave generation upstream at the bow shock and convection downstream to locations within the outer dayside magnetosheath

  6. MIT wavelength tables. Volume 2. Wavelengths by element

    International Nuclear Information System (INIS)

    Phelps, F.M. III.

    1982-01-01

    This volume is the first stage of a project to expand and update the MIT wavelength tables first compiled in the 1930's. For 109,325 atomic emission lines, arranged by element, it presents wavelength in air, wavelength in vacuum, wave number and intensity. All data are stored on computer-readable magnetic tape

  7. Coherence techniques at extreme ultraviolet wavelengths

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Chang [Univ. of California, Berkeley, CA (United States)

    2002-01-01

    The renaissance of Extreme Ultraviolet (EUV) and soft x-ray (SXR) optics in recent years is mainly driven by the desire of printing and observing ever smaller features, as in lithography and microscopy. This attribute is complemented by the unique opportunity for element specific identification presented by the large number of atomic resonances, essentially for all materials in this range of photon energies. Together, these have driven the need for new short-wavelength radiation sources (e.g. third generation synchrotron radiation facilities), and novel optical components, that in turn permit new research in areas that have not yet been fully explored. This dissertation is directed towards advancing this new field by contributing to the characterization of spatial coherence properties of undulator radiation and, for the first time, introducing Fourier optical elements to this short-wavelength spectral region. The first experiment in this dissertation uses the Thompson-Wolf two-pinhole method to characterize the spatial coherence properties of the undulator radiation at Beamline 12 of the Advanced Light Source. High spatial coherence EUV radiation is demonstrated with appropriate spatial filtering. The effects of small vertical source size and beamline apertures are observed. The difference in the measured horizontal and vertical coherence profile evokes further theoretical studies on coherence propagation of an EUV undulator beamline. A numerical simulation based on the Huygens-Fresnel principle is performed.

  8. Wavelength converter technology

    DEFF Research Database (Denmark)

    Kloch, Allan; Hansen, Peter Bukhave; Poulsen, Henrik Nørskov

    1999-01-01

    Wavelength conversion is important since it ensures full flexibility of the WDM network layer. Progress in optical wavelength converter technology is reviewed with emphasis on all-optical wavelength converter types based on semiconductor optical amplifiers.......Wavelength conversion is important since it ensures full flexibility of the WDM network layer. Progress in optical wavelength converter technology is reviewed with emphasis on all-optical wavelength converter types based on semiconductor optical amplifiers....

  9. Acute Zonal Cone Photoreceptor Outer Segment Loss.

    Science.gov (United States)

    Aleman, Tomas S; Sandhu, Harpal S; Serrano, Leona W; Traband, Anastasia; Lau, Marisa K; Adamus, Grazyna; Avery, Robert A

    2017-05-01

    The diagnostic path presented narrows down the cause of acute vision loss to the cone photoreceptor outer segment and will refocus the search for the cause of similar currently idiopathic conditions. To describe the structural and functional associations found in a patient with acute zonal occult photoreceptor loss. A case report of an adolescent boy with acute visual field loss despite a normal fundus examination performed at a university teaching hospital. Results of a complete ophthalmic examination, full-field flash electroretinography (ERG) and multifocal ERG, light-adapted achromatic and 2-color dark-adapted perimetry, and microperimetry. Imaging was performed with spectral-domain optical coherence tomography (SD-OCT), near-infrared (NIR) and short-wavelength (SW) fundus autofluorescence (FAF), and NIR reflectance (REF). The patient was evaluated within a week of the onset of a scotoma in the nasal field of his left eye. Visual acuity was 20/20 OU, and color vision was normal in both eyes. Results of the fundus examination and of SW-FAF and NIR-FAF imaging were normal in both eyes, whereas NIR-REF imaging showed a region of hyporeflectance temporal to the fovea that corresponded with a dense relative scotoma noted on light-adapted static perimetry in the left eye. Loss in the photoreceptor outer segment detected by SD-OCT co-localized with an area of dense cone dysfunction detected on light-adapted perimetry and multifocal ERG but with near-normal rod-mediated vision according to results of 2-color dark-adapted perimetry. Full-field flash ERG findings were normal in both eyes. The outer nuclear layer and inner retinal thicknesses were normal. Localized, isolated cone dysfunction may represent the earliest photoreceptor abnormality or a distinct entity within the acute zonal occult outer retinopathy complex. Acute zonal occult outer retinopathy should be considered in patients with acute vision loss and abnormalities on NIR-REF imaging, especially if

  10. Mechanism of wavelength conversion in polystyrene doped with benzoxanthene: emergence of a complex.

    Science.gov (United States)

    Nakamura, Hidehito; Shirakawa, Yoshiyuki; Kitamura, Hisashi; Sato, Nobuhiro; Shinji, Osamu; Saito, Katashi; Takahashi, Sentaro

    2013-01-01

    Fluorescent guest molecules doped in polymers have been used to convert ultraviolet light into visible light for applications ranging from optical fibres to filters for the cultivation of plants. The wavelength conversion process involves the absorption of light at short wavelengths followed by fluorescence emission at a longer wavelength. However, a precise understanding of the light conversion remains unclear. Here we show light responses for a purified polystyrene base substrates doped with fluorescent benzoxanthene in concentrations varied over four orders of magnitude. The shape of the excitation spectrum for fluorescence emission changes significantly with the concentration of the benzoxanthene, indicating formation of a base substrate/fluorescent molecule complex. Furthermore, the wavelength conversion light yield increases in three stages depending on the nature of the complex. These findings identify a mechanism that will have many applications in wavelength conversion materials.

  11. Smart GSM Based Home Automation System

    OpenAIRE

    Teymourzadeh, Rozita

    2013-01-01

    This research work investigates the potential of ‘Full Home Control’, which is the aim of the Home Automation Systems in near future. The analysis and implementation of the home automation technology using Global System for Mobile Communication (GSM) modem to control home appliances such as light, conditional system, and security system via Short Message Service (SMS) text messages is presented in this paper. The proposed research work is focused on the functionality of the GSM protocol, whic...

  12. Measurement of short bunches

    International Nuclear Information System (INIS)

    Wang, D.X.

    1996-01-01

    In recent years, there has been increasing interest in short electron bunches for different applications such as short wavelength FELs, linear colliders, and advanced accelerators such as laser or plasma wakefield accelerators. One would like to meet various requirements such as high peak current, low momentum spread, high luminosity, small ratio of bunch length to plasma wavelength, and accurate timing. Meanwhile, recent development and advances in RF photoinjectors and various bunching schemes make it possible to generate very short electron bunches. Measuring the longitudinal profile and monitoring bunch length are critical to understand the bunching process and longitudinal beam dynamics, and to commission and operate such short bunch machines. In this paper, several commonly used measurement techniques for subpicosecond bunches and their relative advantages and disadvantages are discussed. As examples, bunch length related measurements at Jefferson Lab are presented. At Jefferson Lab, bunch lengths as short as 84 fs have been systematically measured using a zero-phasing technique. A highly sensitive Coherent Synchrotron Radiation (CSR) detector has been developed to noninvasively monitor bunch length for low charge bunches. Phase transfer function measurements provide a means of correcting RF phase drifts and reproducing RF phases to within a couple of tenths of a degree. The measurement results are in excellent agreement with simulations. A comprehensive bunch length control scheme is presented. (author)

  13. Measurement of short bunches

    International Nuclear Information System (INIS)

    Wang, D.X.

    1996-01-01

    In recent years, there has been increasing interest in short electron bunches for different applications such as short wavelength FELs, linear colliders, and advanced accelerators such as laser or plasma wakefield accelerators. One would like to meet various requirements such as high peak current, low momentum spread, high luminosity, small ratio of bunch length to plasma wavelength, and accurate timing. Meanwhile, recent development and advances in RF photoinjectors and various bunching schemes make it possible to generate very short electron bunches. Measuring the longitudinal profile and monitoring bunch length are critical to understand the bunching process and longitudinal beam dynamics, and to commission and operate such short bunch machines. In this paper, several commonly used measurement techniques for subpicosecond bunches and their relative advantages and disadvantages are discussed. As examples, bunch length related measurements at Jefferson lab are presented. At Jefferson Lab, bunch lengths s short as 84 fs have been systematically measured using a zero-phasing technique. A highly sensitive Coherent Synchrotron Radiation (CSR) detector has been developed to noninvasively monitor bunch length for low charge bunches. Phase transfer function measurements provide a means of correcting RF phase drifts and reproducing RF phases to within a couple of tenths of a degree. The measurement results are in excellent agreement with simulations. A comprehensive bunch length control scheme is presented

  14. Automation and robotics technology for intelligent mining systems

    Science.gov (United States)

    Welsh, Jeffrey H.

    1989-01-01

    The U.S. Bureau of Mines is approaching the problems of accidents and efficiency in the mining industry through the application of automation and robotics to mining systems. This technology can increase safety by removing workers from hazardous areas of the mines or from performing hazardous tasks. The short-term goal of the Automation and Robotics program is to develop technology that can be implemented in the form of an autonomous mining machine using current continuous mining machine equipment. In the longer term, the goal is to conduct research that will lead to new intelligent mining systems that capitalize on the capabilities of robotics. The Bureau of Mines Automation and Robotics program has been structured to produce the technology required for the short- and long-term goals. The short-term goal of application of automation and robotics to an existing mining machine, resulting in autonomous operation, is expected to be accomplished within five years. Key technology elements required for an autonomous continuous mining machine are well underway and include machine navigation systems, coal-rock interface detectors, machine condition monitoring, and intelligent computer systems. The Bureau of Mines program is described, including status of key technology elements for an autonomous continuous mining machine, the program schedule, and future work. Although the program is directed toward underground mining, much of the technology being developed may have applications for space systems or mining on the Moon or other planets.

  15. High color rendering index of remote-type white LEDs with multi-layered quantum dot-phosphor films and short-wavelength pass dichroic filters

    Science.gov (United States)

    Yoon, Hee Chang; Oh, Ji Hye; Do, Young Rag

    2014-09-01

    This paper introduces high color rendering index (CRI) white light-emitting diodes (W-LEDs) coated with red emitting (Sr,Ca)AlSiN3:Eu phosphors and yellowish-green emitting AgIn5S8/ZnS (AIS/ZS) quantum dots (QDs) on glass or a short-wavelength pass dichroic filter (SPDF), which transmit blue wavelength regions and reflect yellow wavelength regions. The red emitting (Sr,Ca)AlSiN3:Eu phosphor film is coated on glass and a SPDF using a screen printing method, and then the yellowish-green emitting AIS/ZS QDs are coated on the red phosphor (Sr,Ca)AlSiN3:Eu film-coated glass and SPDF using the electrospray (e-spray) method.To fabricate the red phosphor film, the optimum amount of phosphor is dispersed in a silicon binder to form a red phosphor paste. The AIS/ZS QDs are mixed with dimethylformamide (DMF), toluene, and poly(methyl methacrylate) (PMMA) for the e-spray coating. The substrates are spin-coated with poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) to fabricate a conductive surface. The CRI of the white LEDs is improved through inserting the red phosphor film between the QD layer and the glass substrate. Furthermore, the light intensities of the multi-layered phosphor films are enhanced through changing the glass substrate to the SPDF. The correlated color temperatures (CCTs) vary as a function of the phosphor concentration in the phosphor paste. The optical properties of the yellowish-green AIS/ZS QDs and red (Sr,Ca)AlSiN3:Eu phosphors are characterized using photoluminescence (PL), and the multi-layered QD-phosphor films are measured using electroluminescence (EL) with an InGaN blue LED (λmax = 450 nm) at 60 mA.

  16. Effective long wavelength scalar dynamics in de Sitter

    Energy Technology Data Exchange (ETDEWEB)

    Moss, Ian; Rigopoulos, Gerasimos, E-mail: ian.moss@newcastle.ac.uk, E-mail: gerasimos.rigopoulos@ncl.ac.uk [School of Mathematics and Statistics, Newcastle University, Herschel Building, Newcastle upon Tyne, NE1 7RU U.K. (United Kingdom)

    2017-05-01

    We discuss the effective infrared theory governing a light scalar's long wavelength dynamics in de Sitter spacetime. We show how the separation of scales around the physical curvature radius k / a ∼ H can be performed consistently with a window function and how short wavelengths can be integrated out in the Schwinger-Keldysh path integral formalism. At leading order, and for time scales Δ t >> H {sup −1}, this results in the well-known Starobinsky stochastic evolution. However, our approach allows for the computation of quantum UV corrections, generating an effective potential on which the stochastic dynamics takes place. The long wavelength stochastic dynamical equations are now second order in time, incorporating temporal scales Δ t ∼ H {sup −1} and resulting in a Kramers equation for the probability distribution—more precisely the Wigner function—in contrast to the more usual Fokker-Planck equation. This feature allows us to non-perturbatively evaluate, within the stochastic formalism, not only expectation values of field correlators, but also the stress-energy tensor of φ.

  17. [The 8-year follow-up study for clinical diagnostic potentials of frequency-doubling technology perimetry for perimetrically normal eyes of open-angle glaucoma patients with unilateral visual field loss].

    Science.gov (United States)

    Fan, X; Wu, L L; Xiao, G G; Ma, Z Z; Liu, F

    2018-03-11

    Objective: To analyze potentials of frequency-doubling technology perimetry (FDP) for diagnosing open-angle glaucoma (OAG) in perimetrically normal eyes of OAG patients diagnosed with standard automated perimetry (SAP) and relating factors from abnormalities on FDP to visual field loss on SAP. Methods: A prospective cohort study. Sixty-eight eyes of 68 OAG patients visiting the ophthalmic clinic of Peking University Third Hospital during November 2003 and October 2007 [32 primary open-angle glaucoma patients and 36 normal tension glaucoma patients, 32 males and 36 females, with an average age of (59±13) years] with unilateral field loss detected by SAP (Octopus101 tG2 program) were examined with the FDP N-30 threshold program (Humphrey Instruments) at baseline. Two groups, FDP positive group and FDP negative group, were divided based on the FDP results, and visual field examinations were followed by a series of SAP examinations for the perimetrically normal eyes over 8 years. During the follow-up, the difference of the converting rate of SAP tests between the two groups was analyzed. Differences between "convertors" and "non-convertors" of SAP tests in the FDP positive group, such as the cup-to-disk ratio and glaucomatous optic neuropathy rate, were also compared with the independent-sample t test or Wilcoxon two-sample test for continuous variable data and the χ(2) test or Fisher exact test for classified variable data and rates. Results: Forty-eight perimetrically normal eyes of 48 participants had complete data and a qualifying follow-up. Baseline FDP results were positive in 33 eyes and negative in 15 eyes. Of the eyes with positive FDP results, 22 eyes developed abnormal SAP results after 4.0 to 90.0 months (median 14.5 months) , whereas none of the eyes with negative FDP results developed abnormal SAP results. For perimetrically normal eyes in the FDP positive group, "converters" showed a greater cup-to-disk ratio (0.73±0.09 vs . 0.63±0.14, Wilcoxon two

  18. Automated Temperature and Emission Measure Analysis of Coronal Loops and Active Regions Observed with the Atmospheric Imaging Assembly on the Solar Dynamics Observatory (SDO/AIA)

    Science.gov (United States)

    Aschwanden, Markus J.; Boerner, Paul; Schrijver, Carolus J.; Malanushenko, Anna

    2013-03-01

    We developed numerical codes designed for automated analysis of SDO/AIA image datasets in the six coronal filters, including: i) coalignment test between different wavelengths with measurements of the altitude of the EUV-absorbing chromosphere, ii) self-calibration by empirical correction of instrumental response functions, iii) automated generation of differential emission measure [DEM] distributions with peak-temperature maps [ T p( x, y)] and emission measure maps [ EM p( x, y)] of the full Sun or active region areas, iv) composite DEM distributions [d EM( T)/d T] of active regions or subareas, v) automated detection of coronal loops, and vi) automated background subtraction and thermal analysis of coronal loops, which yields statistics of loop temperatures [ T e], temperature widths [ σ T], emission measures [ EM], electron densities [ n e], and loop widths [ w]. The combination of these numerical codes allows for automated and objective processing of numerous coronal loops. As an example, we present the results of an application to the active region NOAA 11158, observed on 15 February 2011, shortly before it produced the largest (X2.2) flare during the current solar cycle. We detect 570 loop segments at temperatures in the entire range of log( T e)=5.7 - 7.0 K and corroborate previous TRACE and AIA results on their near-isothermality and the validity of the Rosner-Tucker-Vaiana (RTV) law at soft X-ray temperatures ( T≳2 MK) and its failure at lower EUV temperatures.

  19. [Therapeutic follow-up using automatic perimetry in chronic cerebroretinal ischemia in elderly patients. Prospective double-blind study with graduated dose ginkgo biloba treatment (EGb 761)].

    Science.gov (United States)

    Raabe, A; Raabe, M; Ihm, P

    1991-12-01

    The chronic cerebral retinal insufficiency syndrome in elderly patients is an organ specific expression of a generalized vascular cerebral deficiency. The progress of the disease is characterized by complex symptoms, variation in course, spontaneous remissions and, until recently inadequate diagnostic measurement methods. The new method of automated perimetry with the octopus 2000 P offers a patient-friendly procedure for indirect non-invasive diagnosis of circulatory state in limited cerebral retinal perfusion. In the present study measurements were made with this method on 24 patients (4 men and 20 women with an age of 74.9 +/- 6.9 years). The effect of the extract of Ginkgo biloba (EGb 761) on the reversibility of visual field disturbances was tested using a randomized and double blind study-design in two phases and with two dose levels. The main parameter investigated in this study was the change in the luminous density difference threshold after therapy with EGb 761. In group B (EGb 761 dose 160 mg/day) a significant increase in retinal sensitivity was seen within 4 weeks (p less than 0.05). In the lower dose (80 mg EGb 761/day) group (A), this change in retinal sensitivity was first seen after increasing the dose to 160 mg/day (p less than 0.01). The relative sensitivity of damaged retinal areas was more strongly influenced than "healthy" areas. The assessment by both doctors and patients of the general condition of the patients showed a significant improvement after the course of therapy. The results presented here show that damage to the visual field by chronic lack of bloodflow are significantly reversible.(ABSTRACT TRUNCATED AT 250 WORDS)

  20. Automation of activation analysis

    International Nuclear Information System (INIS)

    Ivanov, I.N.; Ivanets, V.N.; Filippov, V.V.

    1985-01-01

    The basic data on the methods and equipment of activation analysis are presented. Recommendations on the selection of activation analysis techniques, and especially the technique envisaging the use of short-lived isotopes, are given. The equipment possibilities to increase dataway carrying capacity, using modern computers for the automation of the analysis and data processing procedure, are shown

  1. Ultra-short silicon MMI duplexer

    Science.gov (United States)

    Yi, Huaxiang; Huang, Yawen; Wang, Xingjun; Zhou, Zhiping

    2012-11-01

    The fiber-to-the-home (FTTH) systems are growing fast these days, where two different wavelengths are used for upstream and downstream traffic, typically 1310nm and 1490nm. The duplexers are the key elements to separate these wavelengths into different path in central offices (CO) and optical network unit (ONU) in passive optical network (PON). Multimode interference (MMI) has some benefits to be a duplexer including large fabrication tolerance, low-temperature dependence, and low-polarization dependence, but its size is too large to integrate in conventional case. Based on the silicon photonics platform, ultra-short silicon MMI duplexer was demonstrated to separate the 1310nm and 1490nm lights. By studying the theory of self-image phenomena in MMI, the first order images are adopted in order to keep the device short. A cascaded MMI structure was investigated to implement the wavelength splitting, where both the light of 1310nm and 1490nm was input from the same port, and the 1490nm light was coupling cross the first MMI and output at the cross-port in the device while the 1310nm light was coupling through the first and second MMI and output at the bar-port in the device. The experiment was carried on with the SOI wafer of 340nm top silicon. The cascaded MMI was investigated to fold the length of the duplexer as short as 117μm with the extinct ratio over 10dB.

  2. Using a fast dual-wavelength imaging ellipsometric system to measure the flow thickness profile of an oil thin film

    Science.gov (United States)

    Kuo, Chih-Wei; Han, Chien-Yuan; Jhou, Jhe-Yi; Peng, Zeng-Yi

    2017-11-01

    Dual-wavelength light sources with stroboscopic illumination technique were applied in a process of photoelastic modulated ellipsometry to retrieve two-dimensional ellipsometric parameters of thin films on a silicon substrate. Two laser diodes were alternately switched on and modulated by a programmable pulse generator to generate four short pulses at specific temporal phase angles in a modulation cycle, and short pulses were used to freeze the intensity variation of the PEM modulated signal that allows ellipsometric images to be captured by a charge-coupled device. Although the phase retardation of a photoelastic modulator is related to the light wavelength, we employed an equivalent phase retardation technique to avoid any setting from the photoelastic modulator. As a result, the ellipsometric parameters of different wavelengths may be rapidly obtained using this dual-wavelength ellipsometric system every 4 s. Both static and dynamic experiments are demonstrated in this work.

  3. Multiple pathways carry signals from short-wavelength-sensitive ('blue') cones to the middle temporal area of the macaque.

    Science.gov (United States)

    Jayakumar, Jaikishan; Roy, Sujata; Dreher, Bogdan; Martin, Paul R; Vidyasagar, Trichur R

    2013-01-01

    We recorded spike activity of single neurones in the middle temporal visual cortical area (MT or V5) of anaesthetised macaque monkeys. We used flashing, stationary spatially circumscribed, cone-isolating and luminance-modulated stimuli of uniform fields to assess the effects of signals originating from the long-, medium- or short- (S) wavelength-sensitive cone classes. Nearly half (41/86) of the tested MT neurones responded reliably to S-cone-isolating stimuli. Response amplitude in the majority of the neurones tested further (19/28) was significantly reduced, though not always completely abolished, during reversible inactivation of visuotopically corresponding regions of the ipsilateral primary visual cortex (striate cortex, area V1). Thus, the present data indicate that signals originating in S-cones reach area MT, either via V1 or via a pathway that does not go through area V1. We did not find a significant difference between the mean latencies of spike responses of MT neurones to signals that bypass V1 and those that do not; the considerable overlap we observed precludes the use of spike-response latency as a criterion to define the routes through which the signals reach MT.

  4. The dynamics of interacting nonlinearities governing long wavelength driftwave turbulence

    International Nuclear Information System (INIS)

    Newman, D.E.

    1993-09-01

    Because of the ubiquitous nature of turbulence and the vast array of different systems which have turbulent solutions, the study of turbulence is an area of active research. Much present day understanding of turbulence is rooted in the well established properties of homogeneous Navier-Stokes turbulence, which, due to its relative simplicity, allows for approximate analytic solutions. This work examines a group of turbulent systems with marked differences from Navier-Stokes turbulence, and attempts to quantify some of their properties. This group of systems represents a variety of drift wave fluctuations believed to be of fundamental importance in laboratory fusion devices. From extensive simulation of simple local fluid models of long wavelength drift wave turbulence in tokamaks, a reasonably complete picture of the basic properties of spectral transfer and saturation has emerged. These studies indicate that many conventional notions concerning directions of cascades, locality and isotropy of transfer, frequencies of fluctuations, and stationarity of saturation are not valid for moderate to long wavelengths. In particular, spectral energy transfer at long wavelengths is dominated by the E x B nonlinearity, which carries energy to short scale in a manner that is highly nonlocal and anisotropic. In marked contrast to the canonical self-similar cascade dynamics of Kolmogorov, energy is efficiently passed between modes separated by the entire spectrum range in a correlation time. At short wavelengths, transfer is dominated by the polarization drift nonlinearity. While the standard dual cascade applies in this subrange, it is found that finite spectrum size can produce cascades that are reverse directed and are nonconservative in enstrophy and energy similarity ranges. In regions where both nonlinearities are important, cross-coupling between the nolinearities gives rise to large no frequency shifts as well as changes in the spectral dynamics

  5. Transition operators in acoustic-wave diffraction theory. I - General theory. II - Short-wavelength behavior, dominant singularities of Zk0 and Zk0 exp -1

    Science.gov (United States)

    Hahne, G. E.

    1991-01-01

    A formal theory of the scattering of time-harmonic acoustic scalar waves from impenetrable, immobile obstacles is established. The time-independent formal scattering theory of nonrelativistic quantum mechanics, in particular the theory of the complete Green's function and the transition (T) operator, provides the model. The quantum-mechanical approach is modified to allow the treatment of acoustic-wave scattering with imposed boundary conditions of impedance type on the surface (delta-Omega) of an impenetrable obstacle. With k0 as the free-space wavenumber of the signal, a simplified expression is obtained for the k0-dependent T operator for a general case of homogeneous impedance boundary conditions for the acoustic wave on delta-Omega. All the nonelementary operators entering the expression for the T operator are formally simple rational algebraic functions of a certain invertible linear radiation impedance operator which maps any sufficiently well-behaved complex-valued function on delta-Omega into another such function on delta-Omega. In the subsequent study, the short-wavelength and the long-wavelength behavior of the radiation impedance operator and its inverse (the 'radiation admittance' operator) as two-point kernels on a smooth delta-Omega are studied for pairs of points that are close together.

  6. Tunable Optical Tweezers for Wavelength-dependent Measurements

    Science.gov (United States)

    2012-04-23

    have been studied in an optical levitation scheme over short laser wavelength ranges20 and for dye-loaded di- electric particles.21 In the first case...M. Block, IEEE J. Sel. Top. Quantum Electron. 2, 1066 (1996). 7K. Dholakia, W. M. Lee, L. Paterson, M. P. MacDonald, I. Andreev, P. Mthunzi, C. T. A...Brown, R. F. Marchington, and A. C. Riches, IEEE J. Sel. Top. Quantum Electron. 13, 1646 (2007). 8K. Dholakia, M. P. MacDonald, P. Zemanek, and T

  7. Optical frequency-domain reflectometry using multiple wavelength-swept elements of a DFB laser array

    Science.gov (United States)

    DiLazaro, Tom; Nehmetallah, Georges

    2017-02-01

    Coherent optical frequency-domain reflectometry (C-OFDR) is a distance measurement technique with significant sensitivity and detector bandwidth advantages over normal time-of-flight methods. Although several swept-wavelength laser sources exist, many exhibit short coherence lengths, or require precision mechanical tuning components. Semiconductor distributed feedback lasers (DFBs) are advantageous as a mid-to-long range OFDR source because they exhibit a narrow linewidth and can be rapidly tuned simply via injection current. However, the sweep range of an individual DFB is thermally limited. Here, we present a novel high-resolution OFDR system that uses a compact, monolithic 12-element DFB array to create a continuous, gap-free sweep over a wide wavelength range. Wavelength registration is provided by the incorporation of a HCN gas cell and reference interferometer. The wavelength-swept spectra of the 12 DFBs are combined in post-processing to achieve a continuous total wavelength sweep of more than 40 nm (5.4 THz) in the telecommunications C-Band range.

  8. Automated extraction of DNA from clothing

    DEFF Research Database (Denmark)

    Stangegaard, Michael; Hjort, Benjamin Benn; Nøhr Hansen, Thomas

    2011-01-01

    Presence of PCR inhibitors in extracted DNA may interfere with the subsequent quantification and short tandem repeat (STR) reactions used in forensic genetic DNA typing. We have compared three automated DNA extraction methods based on magnetic beads with a manual method with the aim of reducing...

  9. Wavelength switching dynamics of two-colour semiconductor lasers with optical injection and feedback

    International Nuclear Information System (INIS)

    Osborne, S; Heinricht, P; Brandonisio, N; Amann, A; O’Brien, S

    2012-01-01

    The wavelength switching dynamics of two-colour semiconductor lasers with optical injection and feedback are presented. These devices incorporate slotted regions etched into the laser ridge waveguide for tailoring the output spectrum. Experimental measurements are presented demonstrating that optical injection in one or both modes of these devices can induce wavelength bistability. Measured switching dynamics with modulated optical injection are shown to be in excellent agreement with numerical simulations based on a simple rate equation model. We also demonstrate experimentally that time-delayed optical feedback can induce wavelength bistability for short external cavity lengths. Numerical simulations indicate that this two-colour optical feedback system can provide fast optical memory functionality based on injected optical pulses without the need for an external holding beam. (paper)

  10. A compact design for monochromatic OSL measurements in the wavelength range 380-1020 NM

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.; Poolton, N.R.J.; Willumsen, F.

    1994-01-01

    automated Riso TL/OSL dating apparatus, thus allowing for either routine scanning or more detailed thermo-optical investigations. The high throughput efficiency of the unit means that the existing 75 W tungsten-halogen lamp can be directly used for such measurements on both quartz and feldspar samples......The development and performance of a compact module is described that allows for the monochromatic illumination of samples in the wavelength range 380-1020 nm, enabling the measurement of energy-resolved optically stimulated luminescence. The unit is designed to couple directly to the existing....... The design allows for rapid spectral scanning with a choice of resolution of anywhere between 10 and 80 nm: stray light levels are less than 0.01%. The unit can equally be used for recording wavelength-resolved emission spectra, whether photo-excited or thermally stimulated; the capabilities of the system...

  11. Experimental studies on the production and suppression mechanism of the hot electrons produced by short wavelength laser

    International Nuclear Information System (INIS)

    Qi Lanying; Jiang Xiaohua; Zhao Xuewei; Li Sanwei; Zhang Wenhai; Li Chaoguang; Zheng Zhijian; Ding Yongkun

    1999-12-01

    The experiments on gold-disk and hohlraum and plastic hydrocarbon (CH) film targets irradiated by laser beams with wavelength 0.35 μm (Xingguang-II) and 0.53 μm (Shenguang-I) are performed. The characteristics of hot electrons are commonly deduced from spectrum of hard X-ray. Associated with the measurement of backward SRS and 3/2ω 0 , the production mechanism of hot electrons for different target type is analyzed in laser plasma with shorter wavelength. A effective way to suppress hot electrons has been found

  12. Wavelength modulated surface enhanced (resonance) Raman scattering for background-free detection.

    Science.gov (United States)

    Praveen, Bavishna B; Steuwe, Christian; Mazilu, Michael; Dholakia, Kishan; Mahajan, Sumeet

    2013-05-21

    Spectra in surface-enhanced Raman scattering (SERS) are always accompanied by a continuum emission called the 'background' which complicates analysis and is especially problematic for quantification and automation. Here, we implement a wavelength modulation technique to eliminate the background in SERS and its resonant version, surface-enhanced resonance Raman scattering (SERRS). This is demonstrated on various nanostructured substrates used for SER(R)S. An enhancement in the signal to noise ratio for the Raman bands of the probe molecules is also observed. This technique helps to improve the analytical ability of SERS by alleviating the problem due to the accompanying background and thus making observations substrate independent.

  13. Determination of Seed Soundness in Conifers Cryptomeria japonica and Chamaecyparis obtusa Using Narrow-Multiband Spectral Imaging in the Short-Wavelength Infrared Range

    Science.gov (United States)

    Matsuda, Osamu; Hara, Masashi; Tobita, Hiroyuki; Yazaki, Kenichi; Nakagawa, Toshinori; Shimizu, Kuniyoshi; Uemura, Akira; Utsugi, Hajime

    2015-01-01

    Regeneration of planted forests of Cryptomeria japonica (sugi) and Chamaecyparis obtuse (hinoki) is the pressing importance to the forest administration in Japan. Low seed germination rate of these species, however, has hampered low-cost production of their seedlings for reforestation. The primary cause of the low germinability has been attributed to highly frequent formation of anatomically unsound seeds, which are indistinguishable from sound germinable seeds by visible observation and other common criteria such as size and weight. To establish a method for sound seed selection in these species, hyperspectral imaging technique was used to identify a wavelength range where reflectance spectra differ clearly between sound and unsound seeds. In sound seeds of both species, reflectance in a narrow waveband centered at 1,730 nm, corresponding to a lipid absorption band in the short-wavelength infrared (SWIR) range, was greatly depressed relative to that in adjacent wavebands on either side. Such depression was absent or less prominent in unsound seeds. Based on these observations, a reflectance index SQI, abbreviated for seed quality index, was formulated using reflectance at three narrow SWIR wavebands so that it represents the extent of the depression. SQI calculated from seed area-averaged reflectance spectra and spatial distribution patterns of pixelwise SQI within each seed area were both proven as reliable criteria for sound seed selection. Enrichment of sound seeds was accompanied by an increase in germination rate of the seed lot. Thus, the methods described are readily applicable toward low-cost seedling production in combination with single seed sowing technology. PMID:26083366

  14. Wavelength converter placement for different RWA algorithms in wavelength-routed all-optical networks

    Science.gov (United States)

    Chu, Xiaowen; Li, Bo; Chlamtac, Imrich

    2002-07-01

    Sparse wavelength conversion and appropriate routing and wavelength assignment (RWA) algorithms are the two key factors in improving the blocking performance in wavelength-routed all-optical networks. It has been shown that the optimal placement of a limited number of wavelength converters in an arbitrary mesh network is an NP complete problem. There have been various heuristic algorithms proposed in the literature, in which most of them assume that a static routing and random wavelength assignment RWA algorithm is employed. However, the existing work shows that fixed-alternate routing and dynamic routing RWA algorithms can achieve much better blocking performance. Our study in this paper further demonstrates that the wavelength converter placement and RWA algorithms are closely related in the sense that a well designed wavelength converter placement mechanism for a particular RWA algorithm might not work well with a different RWA algorithm. Therefore, the wavelength converter placement and the RWA have to be considered jointly. The objective of this paper is to investigate the wavelength converter placement problem under fixed-alternate routing algorithm and least-loaded routing algorithm. Under the fixed-alternate routing algorithm, we propose a heuristic algorithm called Minimum Blocking Probability First (MBPF) algorithm for wavelength converter placement. Under the least-loaded routing algorithm, we propose a heuristic converter placement algorithm called Weighted Maximum Segment Length (WMSL) algorithm. The objective of the converter placement algorithm is to minimize the overall blocking probability. Extensive simulation studies have been carried out over three typical mesh networks, including the 14-node NSFNET, 19-node EON and 38-node CTNET. We observe that the proposed algorithms not only outperform existing wavelength converter placement algorithms by a large margin, but they also can achieve almost the same performance comparing with full wavelength

  15. Automated rapid chemistry in heavy element research

    International Nuclear Information System (INIS)

    Schaedel, M.

    1994-01-01

    With the increasingly short half-lives of the heavy element isotopes in the transition region from the heaviest actinides to the transactinide elements the demand for automated rapid chemistry techniques is also increasing. Separation times of significantly less than one minute, high chemical yields, high repetition rates, and an adequate detection system are prerequisites for many successful experiments in this field. The development of techniques for separations in the gas phase and in the aqueous phase for applications of chemical or nuclear studies of the heaviest elements are briefly outlined. Typical examples of results obtained with automated techniques are presented for studies up to element 105, especially those obtained with the Automated Rapid Chemistry Apparatus, ARCA. The prospects to investigate the properties of even heavier elements with chemical techniques are discussed

  16. Automation: An Illustration of Social Change.

    Science.gov (United States)

    Warnat, Winifred I.

    Advanced automation is significantly affecting American society and the individual. To understand the extent of this impact, an understanding of the country's service economy is necessary. The United States made the transition from a goods- to service-based economy shortly after World War II. In 1982, services generated 67% of the Gross National…

  17. Group III nitride semiconductors for short wavelength light-emitting devices

    Science.gov (United States)

    Orton, J. W.; Foxon, C. T.

    1998-01-01

    The group III nitrides (AlN, GaN and InN) represent an important trio of semiconductors because of their direct band gaps which span the range 1.95-6.2 eV, including the whole of the visible region and extending well out into the ultraviolet (UV) range. They form a complete series of ternary alloys which, in principle, makes available any band gap within this range and the fact that they also generate efficient luminescence has been the main driving force for their recent technological development. High brightness visible light-emitting diodes (LEDs) are now commercially available, a development which has transformed the market for LED-based full colour displays and which has opened the way to many other applications, such as in traffic lights and efficient low voltage, flat panel white light sources. Continuously operating UV laser diodes have also been demonstrated in the laboratory, exciting tremendous interest for high-density optical storage systems, UV lithography and projection displays. In a remarkably short space of time, the nitrides have therefore caught up with and, in some ways, surpassed the wide band gap II-VI compounds (ZnCdSSe) as materials for short wavelength optoelectronic devices. The purpose of this paper is to review these developments and to provide essential background material in the form of the structural, electronic and optical properties of the nitrides, relevant to these applications. We have been guided by the fact that the devices so far available are based on the binary compound GaN (which is relatively well developed at the present time), together with the ternary alloys AlGaN and InGaN, containing modest amounts of Al or In. We therefore concentrate, to a considerable extent, on the properties of GaN, then introduce those of the alloys as appropriate, emphasizing their use in the formation of the heterostructures employed in devices. The nitrides crystallize preferentially in the hexagonal wurtzite structure and devices have so

  18. Performance of iPad-based threshold perimetry in glaucoma and controls.

    Science.gov (United States)

    Schulz, Angela M; Graham, Elizabeth C; You, YuYi; Klistorner, Alexander; Graham, Stuart L

    2017-10-04

    Independent validation of iPad visual field testing software Melbourne Rapid Fields (MRF). To examine the functionality of MRF and compare its performance with Humphrey SITA 24-2 (HVF). Prospective, cross-sectional validation study. Sixty glaucomas (MD:-5.08±5.22); 17 pre-perimetric, 43 HVF field defects and 25 controls. The MRF was compared with HVF for scotoma detection, global indices, regional mean threshold values and sensitivity/specificity. Long-term test-retest variability was assessed after 6 months. Linear regression and Bland Altman analyses of global indices sensitivity/specificity using ROC curves, intraclass correlations. Using a cluster definition of three points at <1% or two at 0.5% to define a scotoma on HVF, MRF detected 39/54 abnormal hemifields with a similar threshold-based criteria. Global indices were highly correlated between MRF and HVF: MD r 2 = 0.80, PSD r 2 = 0.77, VFI r 2 = 0.85 (all P < 0.0001). For manifest glaucoma patients, correlations of regional mean thresholds ranged from r 2 = 0.45-0.78, despite differing array of tested points between devices. ROC analysis of global indices showed reasonable sensitivity/specificity with AUC values of MD:0.89, PSD:0.85 and VFI:0.88. MRF retest variability was low with ICC values at 0.95 (MD and VFI), 0.94 (PSD). However, individual test point variability for mid-range thresholds was higher. MRF perimetry, despite using a completely different test paradigm, shows good performance characteristics compared to HVF for detection of defects, correlation of global indices and regional mean threshold values. Reproducibility for individual points may limit application for monitoring change over time, and fixation monitoring needs improvement. © 2017 Royal Australian and New Zealand College of Ophthalmologists.

  19. Perimetria azul-amarelo em usuários de tabaco-álcool Blue-on-yellow perimetry in tobacco and alcohol consumers

    Directory of Open Access Journals (Sweden)

    José Fernando de Carvalho Júnior

    2006-10-01

    Full Text Available OBJETIVO: Avaliar as alterações de campo visual em usuários crônicos de tabaco e álcool por meio da perimetria azul-amarelo estratégia 10-2. MÉTODOS: Quarenta e dois olhos de vinte e um voluntários usuários de tabaco e álcool, todos do gênero masculino, foram selecionados após exame oftalmológico completo e normal, sendo submetidos a perimetria azul-amarelo estratégia 10-2. Quinze voluntários participaram do grupo controle. A análise dos dados foi realizada mediante gráfico da profundidade do defeito e número de pontos alterados. RESULTADOS: Observou-se que 40 olhos (95,3% dos usuários crônicos de tabaco e álcool, apresentaram maior freqüência de alterações no gráfico de profundidade do defeito (>10dB e 27 olhos (64,3% apresentaram número de pontos alterados (>10 pontos, (pPURPOSE: To evaluate the visual field changes in blue-on-yellow perimetry (B/Y strategy 10-2 in alcohol and tobacco smoking consumers. METHODS: Forty-two eyes of twenty-one users were studied. Fifteen individuals were used as a control group. All volunteers were males. After normal ophthalmologic examinations, central 10-2 (B/Y was performed in both eyes. Analysis of the results was performed through the alterations in the depth graph defect and number of altered points. RESULTS: It was found that the majority of the chronic alcohol and tobacco smoking consumers had a greater frequency of alterations in the depth graph defect; 40 eyes (95.3%, (>10dB, and 27 eyes (64.3% showed a number of altered points, (>10 points, (p<0.0001. All those who were used as a control group showed alterations in the depth graph defect and number of altered points, but had less than 10dB and 10 altered points, respectively. CONCLUSION: A higher number of abnormal points and depth graph defects and number of altered points were observed in alcohol and tobacco smoking consumers reflecting a higher number of alterations in the cells of the parvocellular system, responsible

  20. Short-wavelength multiline erbium-doped fiber ring laser by a broadband long-period fiber grating inscribed in a taper transition

    International Nuclear Information System (INIS)

    Anzueto-Sánchez, G; Martínez-Rios, A

    2014-01-01

    A stable multiwavelength all-fiber erbium-doped fiber ring laser (EDFRL) based on a broadband long-period fiber grating (LPFG) inscribed in a fiber taper transition is presented. The LPFG’s characteristics were engineered to provide a higher loss at the natural lasing wavelength of the laser cavity. The LPFG inscribed on a taper transition provided a depth greater than 25 dB, and posterior chemical etching provided a broad notch band to inhibit laser generation on the long-wavelength side of the EDF gain. Up to four simultaneous laser wavelengths are generated in the range of 1530–1535 nm. (paper)

  1. On the influence of crystal size and wavelength on native SAD phasing.

    Science.gov (United States)

    Liebschner, Dorothee; Yamada, Yusuke; Matsugaki, Naohiro; Senda, Miki; Senda, Toshiya

    2016-06-01

    Native SAD is an emerging phasing technique that uses the anomalous signal of native heavy atoms to obtain crystallographic phases. The method does not require specific sample preparation to add anomalous scatterers, as the light atoms contained in the native sample are used as marker atoms. The most abundant anomalous scatterer used for native SAD, which is present in almost all proteins, is sulfur. However, the absorption edge of sulfur is at low energy (2.472 keV = 5.016 Å), which makes it challenging to carry out native SAD phasing experiments as most synchrotron beamlines are optimized for shorter wavelength ranges where the anomalous signal of sulfur is weak; for longer wavelengths, which produce larger anomalous differences, the absorption of X-rays by the sample, solvent, loop and surrounding medium (e.g. air) increases tremendously. Therefore, a compromise has to be found between measuring strong anomalous signal and minimizing absorption. It was thus hypothesized that shorter wavelengths should be used for large crystals and longer wavelengths for small crystals, but no thorough experimental analyses have been reported to date. To study the influence of crystal size and wavelength, native SAD experiments were carried out at different wavelengths (1.9 and 2.7 Å with a helium cone; 3.0 and 3.3 Å with a helium chamber) using lysozyme and ferredoxin reductase crystals of various sizes. For the tested crystals, the results suggest that larger sample sizes do not have a detrimental effect on native SAD data and that long wavelengths give a clear advantage with small samples compared with short wavelengths. The resolution dependency of substructure determination was analyzed and showed that high-symmetry crystals with small unit cells require higher resolution for the successful placement of heavy atoms.

  2. Automated Structure Solution with the PHENIX Suite

    Energy Technology Data Exchange (ETDEWEB)

    Zwart, Peter H.; Zwart, Peter H.; Afonine, Pavel; Grosse-Kunstleve, Ralf W.; Hung, Li-Wei; Ioerger, Tom R.; McCoy, A.J.; McKee, Eric; Moriarty, Nigel; Read, Randy J.; Sacchettini, James C.; Sauter, Nicholas K.; Storoni, L.C.; Terwilliger, Tomas C.; Adams, Paul D.

    2008-06-09

    Significant time and effort are often required to solve and complete a macromolecular crystal structure. The development of automated computational methods for the analysis, solution and completion of crystallographic structures has the potential to produce minimally biased models in a short time without the need for manual intervention. The PHENIX software suite is a highly automated system for macromolecular structure determination that can rapidly arrive at an initial partial model of a structure without significant human intervention, given moderate resolution and good quality data. This achievement has been made possible by the development of new algorithms for structure determination, maximum-likelihood molecular replacement (PHASER), heavy-atom search (HySS), template and pattern-based automated model-building (RESOLVE, TEXTAL), automated macromolecular refinement (phenix.refine), and iterative model-building, density modification and refinement that can operate at moderate resolution (RESOLVE, AutoBuild). These algorithms are based on a highly integrated and comprehensive set of crystallographic libraries that have been built and made available to the community. The algorithms are tightly linked and made easily accessible to users through the PHENIX Wizards and the PHENIX GUI.

  3. Automated structure solution with the PHENIX suite

    Energy Technology Data Exchange (ETDEWEB)

    Terwilliger, Thomas C [Los Alamos National Laboratory; Zwart, Peter H [LBNL; Afonine, Pavel V [LBNL; Grosse - Kunstleve, Ralf W [LBNL

    2008-01-01

    Significant time and effort are often required to solve and complete a macromolecular crystal structure. The development of automated computational methods for the analysis, solution, and completion of crystallographic structures has the potential to produce minimally biased models in a short time without the need for manual intervention. The PHENIX software suite is a highly automated system for macromolecular structure determination that can rapidly arrive at an initial partial model of a structure without significant human intervention, given moderate resolution, and good quality data. This achievement has been made possible by the development of new algorithms for structure determination, maximum-likelihood molecular replacement (PHASER), heavy-atom search (HySS), template- and pattern-based automated model-building (RESOLVE, TEXTAL), automated macromolecular refinement (phenix. refine), and iterative model-building, density modification and refinement that can operate at moderate resolution (RESOLVE, AutoBuild). These algorithms are based on a highly integrated and comprehensive set of crystallographic libraries that have been built and made available to the community. The algorithms are tightly linked and made easily accessible to users through the PHENIX Wizards and the PHENIX GUI.

  4. Design of Air Conditioning Automation for Patisserie Shopwindow

    OpenAIRE

    Kemal Tutuncu; Recai Ozcan

    2013-01-01

    Having done in this study, air-conditioning automation for patisserie shopwindow was designed. In the cooling sector it is quite important to cooling up the air temperature in the shopwindow within short time interval. Otherwise the patisseries inside of the shopwindow will be spoilt in a few days. Additionally the humidity is other important parameter for the patisseries kept in shopwindow. It must be raised up to desired level in a quite short time. Traditional patisser...

  5. A 12 GHz wavelength spacing multi-wavelength laser source for wireless communication systems

    Science.gov (United States)

    Peng, P. C.; Shiu, R. K.; Bitew, M. A.; Chang, T. L.; Lai, C. H.; Junior, J. I.

    2017-08-01

    This paper presents a multi-wavelength laser source with 12 GHz wavelength spacing based on a single distributed feedback laser. A light wave generated from the distributed feedback laser is fed into a frequency shifter loop consisting of 50:50 coupler, dual-parallel Mach-Zehnder modulator, optical amplifier, optical filter, and polarization controller. The frequency of the input wavelength is shifted and then re-injected into the frequency shifter loop. By re-injecting the shifted wavelengths multiple times, we have generated 84 optical carriers with 12 GHz wavelength spacing and stable output power. For each channel, two wavelengths are modulated by a wireless data using the phase modulator and transmitted through a 25 km single mode fiber. In contrast to previously developed schemes, the proposed laser source does not incur DC bias drift problem. Moreover, it is a good candidate for radio-over-fiber systems to support multiple users using a single distributed feedback laser.

  6. Long wavelength infrared radiation thermometry for non-contact temperature measurements in gas turbines

    Science.gov (United States)

    Manara, J.; Zipf, M.; Stark, T.; Arduini, M.; Ebert, H.-P.; Tutschke, A.; Hallam, A.; Hanspal, J.; Langley, M.; Hodge, D.; Hartmann, J.

    2017-01-01

    The objective of the EU project "Sensors Towards Advanced Monitoring and Control of Gas Turbine Engines (acronym STARGATE)" is the development of a suite of advanced sensors, instrumentation and related systems in order to contribute to the developing of the next generation of green and efficient gas turbine engines. One work package of the project deals with the design and development of a long wavelength infrared (LWIR) radiation thermometer for the non-contact measurement of the surface temperature of thermal barrier coatings (TBCs) during the operation of gas turbine engines. For opaque surfaces (e.g. metals or superalloys) radiation thermometers which are sensitive in the near or short wavelength infrared are used as state-of-the-art method for non-contact temperature measurements. But this is not suitable for oxide ceramic based TBCs (e.g. partially yttria stabilized zirconia) as oxide ceramics are semi-transparent in the near and short wavelength infrared spectral region. Fortunately the applied ceramic materials are non-transparent in the long wavelength infrared and additionally exhibit a high emittance in this wavelength region. Therefore, a LWIR pyrometer can be used for non-contact temperature measurements of the surfaces of TBCs as such pyrometers overcome the described limitation of existing techniques. For performing non-contact temperature measurements in gas turbines one has to know the infrared-optical properties of the applied TBCs as well as of the hot combustion gas in order to properly analyse the measurement data. For reaching a low uncertainty on the one hand the emittance of the TBC should be high (>0.9) in order to reduce reflections from the hot surrounding and on the other hand the absorbance of the hot combustion gas should be low (<0.1) in order to decrease the influence of the gas on the measured signal. This paper presents the results of the work performed by the authors with focus on the implementation of the LWIR pyrometer and the

  7. Long-wavelength photonic integrated circuits and avalanche photodetectors

    Science.gov (United States)

    Tsou, Yi-Jen D.; Zaytsev, Sergey; Pauchard, Alexandre; Hummel, Steve; Lo, Yu-Hwa

    2001-10-01

    Fast-growing internet traffic volume require high data communication bandwidth over longer distances. Access network bottlenecks put pressure on short-range (SR) telecommunication systems. To effectively address these datacom and telecom market needs, low-cost, high-speed laser modules at 1310 to 1550 nm wavelengths and avalanche photodetectors are required. The great success of GaAs 850nm VCSEls for Gb/s Ethernet has motivated efforts to extend VCSEL technology to longer wavelengths in the 1310 and 1550 nm regimes. However, the technological challenges associated with materials for long wavelength VCSELs are tremendous. Even with recent advances in this area, it is believed that significant additional development is necessary before long wavelength VCSELs that meet commercial specifications will be widely available. In addition, the more stringent OC192 and OC768 specifications for single-mode fiber (SMF) datacom may require more than just a long wavelength laser diode, VCSEL or not, to address numerous cost and performance issues. We believe that photonic integrated circuits (PICs), which compactly integrate surface-emitting lasers with additional active and passive optical components with extended functionality, will provide the best solutions to today's problems. Photonic integrated circuits have been investigated for more than a decade. However, they have produced limited commercial impact to date primarily because the highly complicated fabrication processes produce significant yield and device performance issues. In this presentation, we will discuss a new technology platform of InP-based PICs compatible with surface-emitting laser technology, as well as a high data rate externally modulated laser module. Avalanche photodetectors (APDs) are the key component in the receiver to achieve high data rate over long transmission distance because of their high sensitivity and large gain- bandwidth product. We have used wafer fusion technology to achieve In

  8. Adaptive Blending of Model and Observations for Automated Short-Range Forecasting: Examples from the Vancouver 2010 Olympic and Paralympic Winter Games

    Science.gov (United States)

    Bailey, Monika E.; Isaac, George A.; Gultepe, Ismail; Heckman, Ivan; Reid, Janti

    2014-01-01

    An automated short-range forecasting system, adaptive blending of observations and model (ABOM), was tested in real time during the 2010 Vancouver Olympic and Paralympic Winter Games in British Columbia. Data at 1-min time resolution were available from a newly established, dense network of surface observation stations. Climatological data were not available at these new stations. This, combined with output from new high-resolution numerical models, provided a unique and exciting setting to test nowcasting systems in mountainous terrain during winter weather conditions. The ABOM method blends extrapolations in time of recent local observations with numerical weather predictions (NWP) model predictions to generate short-range point forecasts of surface variables out to 6 h. The relative weights of the model forecast and the observation extrapolation are based on performance over recent history. The average performance of ABOM nowcasts during February and March 2010 was evaluated using standard scores and thresholds important for Olympic events. Significant improvements over the model forecasts alone were obtained for continuous variables such as temperature, relative humidity and wind speed. The small improvements to forecasts of variables such as visibility and ceiling, subject to discontinuous changes, are attributed to the persistence component of ABOM.

  9. A Computational Architecture for Programmable Automation Research

    Science.gov (United States)

    Taylor, Russell H.; Korein, James U.; Maier, Georg E.; Durfee, Lawrence F.

    1987-03-01

    This short paper describes recent work at the IBM T. J. Watson Research Center directed at developing a highly flexible computational architecture for research on sensor-based programmable automation. The system described here has been designed with a focus on dynamic configurability, layered user inter-faces and incorporation of sensor-based real time operations into new commands. It is these features which distinguish it from earlier work. The system is cur-rently being implemented at IBM for research purposes and internal use and is an outgrowth of programmable automation research which has been ongoing since 1972 [e.g., 1, 2, 3, 4, 5, 6] .

  10. WDM cross-connect cascade based on all-optical wavelength converters for routing and wavelength slot interchanging using a reduced number of internal wavelengths

    DEFF Research Database (Denmark)

    Pedersen, Rune Johan Skullerud; Mikkelsen, Benny; Jørgensen, Bo Foged

    1998-01-01

    interchanging can be used to create a robust and nonblocking OXC. However, for an OXC with n fiber inlets each carrying m wavelengths the OXC requires n×m internal wavelengths, which constrains the size of the cross-connect. In this paper we therefore propose and demonstrate an architecture that uses a reduced......Optical transport layers need rearrangeable wavelength-division multiplexing optical cross-connects (OXCs) to increase the capacity and flexibility of the network. It has previously been shown that a cross-connect based on all-optical wavelength converters for routing as well as wavelength slot...... set of internal wavelengths without sacrificing cross-connecting capabilities. By inserting a partly equipped OXC with the new architecture in a 10-Gbit/s re-circulating loop setup we demonstrate the possibility of cascading up to ten OXCs. Furthermore, we investigate the regenerating effect...

  11. Automating InDesign with Regular Expressions

    CERN Document Server

    Kahrel, Peter

    2006-01-01

    If you need to make automated changes to InDesign documents beyond what basic search and replace can handle, you need regular expressions, and a bit of scripting to make them work. This Short Cut explains both how to write regular expressions, so you can find and replace the right things, and how to use them in InDesign specifically.

  12. Ultra-short period X-ray mirrors: Production and investigation

    International Nuclear Information System (INIS)

    Bibishkin, M.S.; Chkhalo, N.I.; Fraerman, A.A.; Pestov, A.E.; Prokhorov, K.A.; Salashchenko, N.N.; Vainer, Yu.A.

    2005-01-01

    Technological problems that deal with manufacturing of highly effective ultra-short (d=0.7-3.2 nm) period X-ray multilayer mirrors (MLM) are discussed in the article. In an example of Cr/Sc and W/B 4 C MLM it is experimentally shown, that the problem of periodicity and selectivity for multilayer dispersive X-ray elements has been generally solved by now. However, the problem of short-period MLM reflectivity increase related to existing of transitive borders between layers in structures remains rather urgent. The new technique of tungsten deposition using the RF source in order to decrease roughness in borders is discussed and tested. The results of measurements on wavelengths of 0.154, 0.834 and 1.759 nm are given. The RbAP crystals ordinary used in experiments and short-period W/B 4 C MLM produced are compared. The specular and non-specular characteristics of scattering on the 0.154 nm wavelengths are also measured in order to study transitive borders structures

  13. Wavelength conversion devices

    DEFF Research Database (Denmark)

    Mikkelsen, Benny; Durhuus, Terji; Jørgensen, Carsten

    1996-01-01

    system requirements. The ideal wavelength converter should be transparent to the bit rate and signal format and provide an unchirped output signal with both a high extinction ratio and a large signal-to-noise ratio. It should allow conversion to both shorter and longer wavelengths with equal performance...

  14. Probabilistic classification method on multi wavelength chromatographic data for photosynthetic pigments identification

    Science.gov (United States)

    Prilianti, K. R.; Setiawan, Y.; Indriatmoko, Adhiwibawa, M. A. S.; Limantara, L.; Brotosudarmo, T. H. P.

    2014-02-01

    Environmental and health problem caused by artificial colorant encourages the increasing usage of natural colorant nowadays. Natural colorant refers to the colorant that is derivate from living organism or minerals. Extensive research topic has been done to exploit these colorant, but recent data shows that only 0.5% of the wide range of plant pigments in the earth has been exhaustively used. Hence development of the pigment characterization technique is an important consideration. High-performance liquid chromatography (HPLC) is a widely used technique to separate pigments in a mixture and identify it. In former HPLC fingerprinting, pigment characterization was based on a single chromatogram from a fixed wavelength (one dimensional) and discard the information contained at other wavelength. Therefore, two dimensional fingerprints have been proposed to use more chromatographic information. Unfortunately this method leads to the data processing problem due to the size of its data matrix. The other common problem in the chromatogram analysis is the subjectivity of the researcher in recognizing the chromatogram pattern. In this research an automated analysis method of the multi wavelength chromatographic data was proposed. Principal component analysis (PCA) was used to compress the data matrix and Maximum Likelihood (ML) classification was applied to identify the chromatogram pattern of the existing pigments in a mixture. Three photosynthetic pigments were selected to show the proposed method. Those pigments are β-carotene, fucoxanthin and zeaxanthin. The result suggests that the method could well inform the existence of the pigments in a particular mixture. A simple computer application was also developed to facilitate real time analysis. Input of the application is multi wavelength chromatographic data matrix and the output is information about the existence of the three pigments.

  15. Automated Parallel Capillary Electrophoretic System

    Science.gov (United States)

    Li, Qingbo; Kane, Thomas E.; Liu, Changsheng; Sonnenschein, Bernard; Sharer, Michael V.; Kernan, John R.

    2000-02-22

    An automated electrophoretic system is disclosed. The system employs a capillary cartridge having a plurality of capillary tubes. The cartridge has a first array of capillary ends projecting from one side of a plate. The first array of capillary ends are spaced apart in substantially the same manner as the wells of a microtitre tray of standard size. This allows one to simultaneously perform capillary electrophoresis on samples present in each of the wells of the tray. The system includes a stacked, dual carousel arrangement to eliminate cross-contamination resulting from reuse of the same buffer tray on consecutive executions from electrophoresis. The system also has a gel delivery module containing a gel syringe/a stepper motor or a high pressure chamber with a pump to quickly and uniformly deliver gel through the capillary tubes. The system further includes a multi-wavelength beam generator to generate a laser beam which produces a beam with a wide range of wavelengths. An off-line capillary reconditioner thoroughly cleans a capillary cartridge to enable simultaneous execution of electrophoresis with another capillary cartridge. The streamlined nature of the off-line capillary reconditioner offers the advantage of increased system throughput with a minimal increase in system cost.

  16. Role of short-wavelength filtering lenses in delaying myopia progression and amelioration of asthenopia in juveniles

    Directory of Open Access Journals (Sweden)

    Hai-Lan Zhao

    2017-08-01

    Full Text Available AIM: To evaluate the positive effects of blue-violet light filtering lenses in delaying myopia and relieving asthenopia in juveniles. METHODS: Sixty ametropia juveniles (aged range, 11-15y were randomized into two groups: the test group (30 children, 60 eyes, wearing blue-violet light filtering lenses; and the control group (30 children, 60 eyes, wearing ordinary aspherical lenses. Baseline refractive power of the affected eyes and axial length of the two groups was recorded. After 1-year, the patients underwent contrast sensitivity (glare and non-glare under bright and dark conditions, accommodation-related testing, asthenopia questionnaire assessment, and adverse reaction questionnaire assessment. RESULTS: After 1y of wearing the filtering lenses, changes in refractive power and axial length were not significantly different between the two groups (P>0.05. Under bright conditions, the contrast sensitivities at low and medium-frequency grating (vision angles of 6.3°, 4.0°, and 2.5° with glare in the test group were significantly higher than in the control group (P0.05. In the test group, the amplitude of accommodation, accommodative lag, and accommodative sensitivity of patients wearing glasses for 6 and 12mo were significantly elevated (P0.05, and the asthenopia grating was not significantly decreased (P>0.05. In addition, after wearing glasses for 6 to 12mo, the asthenopia grating of patients in the test group decreased significantly compared with the control group (P0.05. CONCLUSION: A 1-year follow-up reveal that compare with ordinary glasses, short-wavelength filtering lenses (blue/violet-light filters increase the low- and medium-frequency contrast sensitivity under bright conditions and improved accommodation. They effectively relieved asthenopia without severe adverse reactions, suggesting potential for clinical application. However, no significant advantages in terms of refractive power or axial length progression were found compared

  17. Efficient soft x-ray generation in short wavelength laser produced plasmas

    International Nuclear Information System (INIS)

    Mochizuki, T.; Yamanaka, C.

    1987-01-01

    Intense x-ray generation in 1.053, 0.53, 0.26 μm laser-produced plasma has been investigated in the photon energy range of 0.1 to 3keV. The x-ray spectrum is found to have several humps which move to the higher energy side as the atomic number of the target increases. This atomic dependence is explained by a semi-Moseley's law and allows us to predict a target material most suitable for generating the photons of desired energies. Conversion efficiencies of 1.5 -- 3keV x-rays are obtained also as a function of laser wavelength at the intensity of 10/sup 13/W/cm/sup 2/. The conversion efficiency of keV x rays has been enhanced by a factor of 2 -- 3 with a controlled prepulse laser. From the semi-Moseley's law we find that cryogenic targets using either Xe or Kr in a liquid or solid phase may be most useful for a number of applications because they radiate 1 -- 3 keV x rays efficiently and never deposit on the x-ray optical components and the objects to be exposed

  18. Effects of low or high doses of short wavelength ultraviolet light (UVB) on Langerhans cells and skin allograft survival

    International Nuclear Information System (INIS)

    Odling, K.A.; Halliday, G.M.; Muller, H.K.

    1987-01-01

    Donor C57BL mouse shaved dorsal trunk or tail skin was exposed to high (200 mJ/cm 2 ) or low (40 mJ/cm 2 ) doses of short wavelength ultraviolet light (UVB) before grafting on to the thorax of BALB/c mouse recipients of the same sex. Skin grafted 1-14 days following a single high dose of UVB irradiation was ultrastructurally depleted of LC and survived significantly longer than unirradiated skin before being rejected. After a 21-day interval between exposure and grafting when LC were again present in the epidermis there was no significant difference between treated and control graft survival. Exposure to low dose UVB irradiation only significantly increased graft survival for skin transplanted 1-3 days after irradiation; skin grafted 4 days following irradiation survived for a similar period to unirradiated control skin grafts. Electronmicroscopy showed that the low UVB dose did not deplete LC from the epidermis. We conclude that after low dose UVB treatment the class II MHC antigens on the LC Plasma membrane were lost temporarily, thus prolonging graft survival, but when the plasma membrane antigens were re-expressed graft survival returned to normal. In contrast, high-dose UVB irradiation prolonged graft survival by depleting LC from the epidermis, with graft survival only returning to control values as LC repopulated the epidermis

  19. Automation in high-content flow cytometry screening.

    Science.gov (United States)

    Naumann, U; Wand, M P

    2009-09-01

    High-content flow cytometric screening (FC-HCS) is a 21st Century technology that combines robotic fluid handling, flow cytometric instrumentation, and bioinformatics software, so that relatively large numbers of flow cytometric samples can be processed and analysed in a short period of time. We revisit a recent application of FC-HCS to the problem of cellular signature definition for acute graft-versus-host-disease. Our focus is on automation of the data processing steps using recent advances in statistical methodology. We demonstrate that effective results, on par with those obtained via manual processing, can be achieved using our automatic techniques. Such automation of FC-HCS has the potential to drastically improve diagnosis and biomarker identification.

  20. Intracluster dust, circumstellar shells, and the wavelength dependence of polarization in orion

    International Nuclear Information System (INIS)

    Breger, M.

    1977-01-01

    The wavelength dependence of polarization of 21 polarized stars near the Orion Nebula has been measured. Most stars fit the standard interstellar law. The wavelength of maximum linear polarization, lambda/sub max/, ranges from normal values to 0.71μm. The polarimetric, spectroscopic, and photometric data support a normal reddening law (Rapprox. =3) for most Orion stars, and present evidence for unusually large grain sizes in front of some Orion stars. For the stars BR 545 and BR 885 large values of lambda/sub max/ are associated with unusually large values of total to selective extinction.A division of the observed polarization into intracluster dust and circumstellar shell components shows that the presence of shells does not usually lead to linear polarization in the optical wavelength region. Also, no association of polarization with known light variability could be found. The nature of the intracluster dust clouds is discussed briefly.The results of searches for circular polarization as well as short-period variability are presented in two appendices

  1. The use of automated assessments in internet-based CBT: The computer will be with you shortly

    Directory of Open Access Journals (Sweden)

    Elizabeth C. Mason

    2014-10-01

    Full Text Available There is evidence from randomized control trials that internet-based cognitive behavioral therapy (iCBT is efficacious in the treatment of anxiety and depression, and recent research demonstrates the effectiveness of iCBT in routine clinical care. The aims of this study were to implement and evaluate a new pathway by which patients could access online treatment by completing an automated assessment, rather than seeing a specialist health professional. We compared iCBT treatment outcomes in patients who received an automated pre-treatment questionnaire assessment with patients who were assessed by a specialist psychiatrist prior to treatment. Participants were treated as part of routine clinical care and were therefore not randomized. The results showed that symptoms of anxiety and depression decreased significantly with iCBT, and that the mode of assessment did not affect outcome. That is, a pre-treatment assessment by a psychiatrist conferred no additional treatment benefits over an automated assessment. These findings suggest that iCBT is effective in routine care and may be implemented with an automated assessment. By providing wider access to evidence-based interventions and reducing waiting times, the use of iCBT within a stepped-care model is a cost-effective way to reduce the burden of disease caused by these common mental disorders.

  2. An automated quasi-continuous capillary refill timing device

    International Nuclear Information System (INIS)

    Blaxter, L L; Morris, D E; Crowe, J A; Hayes-Gill, B R; Henry, C; Hill, S; Sharkey, D; Vyas, H

    2016-01-01

    Capillary refill time (CRT) is a simple means of cardiovascular assessment which is widely used in clinical care. Currently, CRT is measured through manual assessment of the time taken for skin tone to return to normal colour following blanching of the skin surface. There is evidence to suggest that manually assessed CRT is subject to bias from ambient light conditions, a lack of standardisation of both blanching time and manually applied pressure, subjectiveness of return to normal colour, and variability in the manual assessment of time. We present a novel automated system for CRT measurement, incorporating three components: a non-invasive adhesive sensor incorporating a pneumatic actuator, a diffuse multi-wavelength reflectance measurement device, and a temperature sensor; a battery operated datalogger unit containing a self contained pneumatic supply; and PC based data analysis software for the extraction of refill time, patient skin surface temperature, and sensor signal quality. Through standardisation of the test, it is hoped that some of the shortcomings of manual CRT can be overcome. In addition, an automated system will facilitate easier integration of CRT into electronic record keeping and clinical monitoring or scoring systems, as well as reducing demands on clinicians. Summary analysis of volunteer (n  =  30) automated CRT datasets are presented, from 15 healthy adults and 15 healthy children (aged from 5 to 15 years), as their arms were cooled from ambient temperature to 5°C. A more detailed analysis of two typical datasets is also presented, demonstrating that the response of automated CRT to cooling matches that of previously published studies. (paper)

  3. A HIGH-RESOLUTION, MULTI-EPOCH SPECTRAL ATLAS OF PECULIAR STARS INCLUDING RAVE, GAIA , AND HERMES WAVELENGTH RANGES

    International Nuclear Information System (INIS)

    Tomasella, Lina; Munari, Ulisse; Zwitter, Tomaz

    2010-01-01

    We present an Echelle+CCD, high signal-to-noise ratio, high-resolution (R = 20,000) spectroscopic atlas of 108 well-known objects representative of the most common types of peculiar and variable stars. The wavelength interval extends from 4600 to 9400 A and includes the RAVE, Gaia, and HERMES wavelength ranges. Multi-epoch spectra are provided for the majority of the observed stars. A total of 425 spectra of peculiar stars, which were collected during 56 observing nights between 1998 November and 2002 August, are presented. The spectra are given in FITS format and heliocentric wavelengths, with accurate subtraction of both the sky background and the scattered light. Auxiliary material useful for custom applications (telluric dividers, spectrophotometric stars, flat-field tracings) is also provided. The atlas aims to provide a homogeneous database of the spectral appearance of stellar peculiarities, a tool useful both for classification purposes and inter-comparison studies. It could also serve in the planning and development of automated classification algorithms designed for RAVE, Gaia, HERMES, and other large-scale spectral surveys. The spectrum of XX Oph is discussed in some detail as an example of the content of the present atlas.

  4. E-health, phase two: the imperative to integrate process automation with communication automation for large clinical reference laboratories.

    Science.gov (United States)

    White, L; Terner, C

    2001-01-01

    The initial efforts of e-health have fallen far short of expectations. They were buoyed by the hype and excitement of the Internet craze but limited by their lack of understanding of important market and environmental factors. E-health now recognizes that legacy systems and processes are important, that there is a technology adoption process that needs to be followed, and that demonstrable value drives adoption. Initial e-health transaction solutions have targeted mostly low-cost problems. These solutions invariably are difficult to integrate into existing systems, typically requiring manual interfacing to supported processes. This limitation in particular makes them unworkable for large volume providers. To meet the needs of these providers, e-health companies must rethink their approaches, appropriately applying technology to seamlessly integrate all steps into existing business functions. E-automation is a transaction technology that automates steps, integration of steps, and information communication demands, resulting in comprehensive automation of entire business functions. We applied e-automation to create a billing management solution for clinical reference laboratories. Large volume, onerous regulations, small margins, and only indirect access to patients challenge large laboratories' billing departments. Couple these problems with outmoded, largely manual systems and it becomes apparent why most laboratory billing departments are in crisis. Our approach has been to focus on the most significant and costly problems in billing: errors, compliance, and system maintenance and management. The core of the design relies on conditional processing, a "universal" communications interface, and ASP technologies. The result is comprehensive automation of all routine processes, driving out errors and costs. Additionally, compliance management and billing system support and management costs are dramatically reduced. The implications of e-automated processes can extend

  5. Automated radiochemical processing for clinical PET

    International Nuclear Information System (INIS)

    Padgett, H.C.; Schmidt, D.G.; Bida, G.T.; Wieland, B.W.; Pekrul, E.; Kingsbury, W.G.

    1991-01-01

    With the recent emergence of positron emission tomography (PET) as a viable clinical tool, there is a need for a convenient, cost-effective source of the positron emitter-labeled radiotracers labeled with carbon-11, nitrogen-13, oxygen-15, and fluorine-18. These short-lived radioisotopes are accelerator produced and thus, require a cyclotron and radiochemistry processing instrumentation that can be operated 3 in a clinical environment by competant technicians. The basic goal is to ensure safety and reliability while setting new standards for economy and ease of operation. The Siemens Radioisotope Delivery System (RDS 112) is a fully automated system dedicated to the production and delivery of positron-emitter labeled precursors and radiochemicals required to support a clinical PET imaging program. Thus, the entire RDS can be thought of as an automated radiochemical processing apparatus

  6. Short-timescale variability in cataclysmic binaries

    International Nuclear Information System (INIS)

    Cordova, F.A.; Mason, K.O.

    1982-01-01

    Rapid variability, including flickering and pulsations, has been detected in cataclysmic binaries at optical and x-ray frequencies. In the case of the novalike variable TT Arietis, simultaneous observations reveal that the x-ray and optical flickering activity is strongly correlated, while short period pulsations are observed that occur at the same frequencies in both wavelength bands

  7. The evolution of automation and robotics in manned spaceflight

    Science.gov (United States)

    Moser, T. L.; Erickson, J. D.

    1986-01-01

    The evolution of automation on all manned spacecraft including the Space Shuttle is reviewed, and a concept for increasing automation and robotics from the current Shuttle Remote Manipulator System (RMS) to an autonomous system is presented. The requirements for robotic elements are identified for various functions on the Space Station, including extravehicular functions and functions within laboratory and habitation modules which expand man's capacity in space and allow selected teleoperation from the ground. The initial Space Station will employ a telerobot and necessary knowledge based systems as an advisory to the crew on monitoring, fault diagnosis, and short term planning and scheduling.

  8. Low-cost automated system for phase-shifting and phase retrieval based on the tunability of a laser diode

    Science.gov (United States)

    Rivera-Ortega, Uriel; Dirckx, Joris

    2016-09-01

    A low-cost and fully automated process for phase-shifting interferometry by continuously changing and turning on-off the input voltage of a laser diode under the scheme of an unbalanced Twyman-Green interferometer setup is presented. The input signal of a laser diode is controlled by a Data Acquisition (NI-DAQ) device which permits to change its wavelength according to its tunability features. The automation and data analysis will be done using LabVIEW in combination with MATLAB. By using Carré algorithm the phase map is obtained. Measurements of visibility and phase-shift to verify the PSI requirements are also shown.

  9. Performance of a fully automated scatterometer for BRDF and BTDF measurements at visible and infrared wavelengths

    International Nuclear Information System (INIS)

    Anderson, S.; Shepard, D.F.; Pompea, S.M.; Castonguay, R.

    1989-01-01

    The general performance of a fully automated scatterometer shows that the instrument can make rapid, accurate BRDF (bidirectional reflectance distribution function) and BTDF (bidirectional transmittance distribution function) measurements of optical surfaces over a range of approximately ten orders of magnitude in BRDF. These measurements can be made for most surfaces even with the detector at the specular angle, because of beam-attenuation techniques. He-Ne and CO2 lasers are used as sources in conjunction with a reference detector and chopper

  10. Broadband multi-wavelength Brillouin lasers with an operating wavelength range of 1500–1600 nm generated by four-wave mixing in a dual wavelength Brillouin fiber laser cavity

    Science.gov (United States)

    Li, Q.; Jia, Z. X.; Weng, H. Z.; Li, Z. R.; Yang, Y. D.; Xiao, J. L.; Chen, S. W.; Huang, Y. Z.; Qin, W. P.; Qin, G. S.

    2018-05-01

    We demonstrate broadband multi-wavelength Brillouin lasers with an operating wavelength range of 1500–1600 nm and a frequency separation of ~9.28 GHz generated by four-wave mixing in a dual wavelength Brillouin fiber laser cavity. By using one continuous-wave laser as the pump source, multi-wavelength Brillouin lasers with an operating wavelength range of 1554–1574 nm were generated via cascaded Brillouin scattering and four-wave mixing. Interestingly, when pumped by two continuous-wave lasers with an appropriate frequency separation, the operating wavelength range of the multi-wavelength Brillouin lasers was increased to 1500–1600 nm due to cavity-enhanced cascaded four-wave mixing among the frequency components generated by two pump lasers in the dual wavelength Brillouin laser cavity.

  11. Two-photon interference at telecom wavelengths for time-bin-encoded single photons from quantum-dot spin qubits.

    Science.gov (United States)

    Yu, Leo; Natarajan, Chandra M; Horikiri, Tomoyuki; Langrock, Carsten; Pelc, Jason S; Tanner, Michael G; Abe, Eisuke; Maier, Sebastian; Schneider, Christian; Höfling, Sven; Kamp, Martin; Hadfield, Robert H; Fejer, Martin M; Yamamoto, Yoshihisa

    2015-11-24

    Practical quantum communication between remote quantum memories rely on single photons at telecom wavelengths. Although spin-photon entanglement has been demonstrated in atomic and solid-state qubit systems, the produced single photons at short wavelengths and with polarization encoding are not suitable for long-distance communication, because they suffer from high propagation loss and depolarization in optical fibres. Establishing entanglement between remote quantum nodes would further require the photons generated from separate nodes to be indistinguishable. Here, we report the observation of correlations between a quantum-dot spin and a telecom single photon across a 2-km fibre channel based on time-bin encoding and background-free frequency downconversion. The downconverted photon at telecom wavelengths exhibits two-photon interference with another photon from an independent source, achieving a mean wavepacket overlap of greater than 0.89 despite their original wavelength mismatch (900 and 911 nm). The quantum-networking operations that we demonstrate will enable practical communication between solid-state spin qubits across long distances.

  12. Altering user' acceptance of automation through prior automation exposure.

    Science.gov (United States)

    Bekier, Marek; Molesworth, Brett R C

    2017-06-01

    Air navigation service providers worldwide see increased use of automation as one solution to overcome the capacity constraints imbedded in the present air traffic management (ATM) system. However, increased use of automation within any system is dependent on user acceptance. The present research sought to determine if the point at which an individual is no longer willing to accept or cooperate with automation can be manipulated. Forty participants underwent training on a computer-based air traffic control programme, followed by two ATM exercises (order counterbalanced), one with and one without the aid of automation. Results revealed after exposure to a task with automation assistance, user acceptance of high(er) levels of automation ('tipping point') decreased; suggesting it is indeed possible to alter automation acceptance. Practitioner Summary: This paper investigates whether the point at which a user of automation rejects automation (i.e. 'tipping point') is constant or can be manipulated. The results revealed after exposure to a task with automation assistance, user acceptance of high(er) levels of automation decreased; suggesting it is possible to alter automation acceptance.

  13. Experimental Demonstration of OCDMA Transmission Using a Three-Dimensional (Time-Wavelength-Polarization) Codeset

    Science.gov (United States)

    McGeehan, John E.; Motaghian Nezam, S. M. R.; Saghari, P.; Willner, Alan E.; Omrani, Reza; Vijay Kumar, P.

    2005-10-01

    We experimentally demonstrate a three-dimensional (3-D) optical code-division multiple-access (OCDMA) transmission system that encodes data on time, wavelength, and polarization. Such a system may be ideal for use in short-distance optical local area networks (LANs), where polarization states remain fairly stable. This type of coding can increase the number of potential users, by a factor of approximately 2kappa, over a conventional two-dimensional (2-D) code given the same code constraints, where"kappa"is the number of collisions the codeset will allow. We encode 1-Gbit/s, 11-Gchip/s data with an 11-chip, 4-wavelength, weight-4 (per polarization) code using free-space and fiber delay lines and polarization beam combiners and decode using a polarization beam splitter, wavelength demultiplexers, and additional fiber/free-space delays. After threshold detection using independent detectors for each polarization state, we obtain 1-Gbit/s nonreturn to zero (NRZ) output data. Encoding, transmission decoding, and detection carry a penalty of 1.8 dB.

  14. FREQUENT SUBCLINICAL MACULAR CHANGES IN COMBINED BRAF/MEK INHIBITION WITH HIGH-DOSE HYDROXYCHLOROQUINE AS TREATMENT FOR ADVANCED METASTATIC BRAF MUTANT MELANOMA: Preliminary Results From a Phase I/II Clinical Treatment Trial.

    Science.gov (United States)

    Nti, Akosua A; Serrano, Leona W; Sandhu, Harpal S; Uyhazi, Katherine E; Edelstein, Ilaina D; Zhou, Elaine J; Bowman, Scott; Song, Delu; Gangadhar, Tara C; Schuchter, Lynn M; Mitnick, Sheryl; Huang, Alexander; Nichols, Charles W; Amaravadi, Ravi K; Kim, Benjamin J; Aleman, Tomas S

    2018-01-10

    To assess the potential ocular toxicity of a combined BRAF inhibition (BRAFi) + MEK inhibition (MEKi) + hydroxychloroquine (HCQ) regime used to treat metastatic BRAF mutant melanoma. Patients with stage IV metastatic melanoma and BRAF V600E mutations (n = 11, 31-68 years of age) were included. Treatment was with oral dabrafenib, 150 mg bid, trametinib, 2 mg/day, and HCQ, 400 mg to 600 mg bid. An ophthalmic examination, spectral domain optical coherence tomography, near-infrared and short-wavelength fundus autofluorescence, and static perimetry were performed at baseline, 1 month, and q/6 months after treatment. There were no clinically significant ocular events; there was no ocular inflammation. The only medication-related change was a separation of the photoreceptor outer segment tip from the apical retinal pigment epithelium that could be traced from the fovea to the perifoveal retina noted in 9/11 (82%) of the patients. There were no changes in retinal pigment epithelium melanization or lipofuscin content by near-infrared fundus autofluorescence and short-wavelength fundus autofluorescence, respectively. There were no inner retinal or outer nuclear layer changes. Visual acuities and sensitivities were unchanged. BRAFi (trametinib) + MEKi (dabrafenib) + HCQ causes very frequent, subclinical separation of the photoreceptor outer segment from the apical retinal pigment epithelium without inner retinal changes or signs of inflammation. The changes suggest interference with the maintenance of the outer retinal barrier and/or phagocytic/pump functions of the retinal pigment epithelium by effective MEK inhibition.

  15. Short-wavelength out-of-band EUV emission from Sn laser-produced plasma

    Science.gov (United States)

    Torretti, F.; Schupp, R.; Kurilovich, D.; Bayerle, A.; Scheers, J.; Ubachs, W.; Hoekstra, R.; Versolato, O. O.

    2018-02-01

    We present the results of spectroscopic measurements in the extreme ultraviolet regime (7-17 nm) of molten tin microdroplets illuminated by a high-intensity 3 J, 60 ns Nd:YAG laser pulse. The strong 13.5 nm emission from this laser-produced plasma (LPP) is of relevance for next-generation nanolithography machines. Here, we focus on the shorter wavelength features between 7 and 12 nm which have so far remained poorly investigated despite their diagnostic relevance. Using flexible atomic code calculations and local thermodynamic equilibrium arguments, we show that the line features in this region of the spectrum can be explained by transitions from high-lying configurations within the Sn{}8+-Sn{}15+ ions. The dominant transitions for all ions but Sn{}8+ are found to be electric-dipole transitions towards the n = 4 ground state from the core-excited configuration in which a 4p electron is promoted to the 5s subshell. Our results resolve some long-standing spectroscopic issues and provide reliable charge state identification for Sn LPP, which could be employed as a useful tool for diagnostic purposes.

  16. 12th International Conference on Informatics in Control, Automation and Robotics

    CERN Document Server

    Gusikhin, Oleg; Madani, Kurosh; Sasiadek, Jurek

    2016-01-01

    The present book includes a set of selected extended papers from the 11th International Conference on Informatics in Control, Automation and Robotics (ICINCO 2014), held in Vienna, Austria, from 1 to 3 September 2014. The conference brought together researchers, engineers and practitioners interested in the application of informatics to Control, Automation and Robotics. Four simultaneous tracks will be held, covering Intelligent Control Systems, Optimization, Robotics, Automation, Signal Processing, Sensors, Systems Modelling and Control, and Industrial Engineering, Production and Management. Informatics applications are pervasive in many areas of Control, Automation and Robotics. ICINCO 2014 received 301 submissions, from 49 countries, in all continents. After a double blind paper review performed by the Program Committee, 20% were accepted as full papers and thus selected for oral presentation. Additional papers were accepted as short papers and posters. A further selection was made after the Conference, ba...

  17. 12th International Conference on Informatics in Control, Automation and Robotics

    CERN Document Server

    Madani, Kurosh; Gusikhin, Oleg; Sasiadek, Jurek

    2016-01-01

    The present book includes a set of selected extended papers from the 12th International Conference on Informatics in Control, Automation and Robotics (ICINCO 2015), held in Colmar, France, from 21 to 23 July 2015. The conference brought together researchers, engineers and practitioners interested in the application of informatics to Control, Automation and Robotics. Four simultaneous tracks will be held, covering Intelligent Control Systems, Optimization, Robotics, Automation, Signal Processing, Sensors, Systems Modelling and Control, and Industrial Engineering, Production and Management. Informatics applications are pervasive in many areas of Control, Automation and Robotics. ICINCO 2015 received 214 submissions, from 42 countries, in all continents. After a double blind paper review performed by the Program Committee, 14% were accepted as full papers and thus selected for oral presentation. Additional papers were accepted as short papers and posters. A further selection was made after the Conference, based ...

  18. Multi-wavelength copper vapour lasers for novel materials processing application

    International Nuclear Information System (INIS)

    Knowles, M.; Foster-Turner, R.; Kearsley, A.; Evans, J.

    1995-01-01

    The copper vapour laser (CVL) is a high average power, short pulse laser with a multi-kilohertz pulse repetition rate. The CVL laser lines (511 nm and 578 nm) combined with the good beam quality and high peak power available from these lasers allow it to operate in a unique parameter space. Consequently, it has demonstrated many unique and advantageous machining characteristics. We have also demonstrated efficient conversion of CVL radiation to other wavelengths using non-linear frequency conversion, dye lasers and Ti:AL 2 O 3 . Output powers of up to 4 W at 255 nm have been achieved by frequency doubling. The frequency doubled CVL is inherently narrow linewidth and frequency locked making it a suitable source for UV photolithography. Slope efficiencies in excess of 25 % have been achieved with CVL pumped Ti:Al 2 O 3 and dye lasers. These laser extend the wavelengths options into the red and infrared regions of the spectrum. The near diffraction limited beams from these tunable lasers can be efficiently frequency doubled into the blue and near UV. The wide range of wavelength options from the CVL enable a wide variety of materials processing and material interactions to be explored. A European consortium for Copper Laser Applications in Manufacture and Production (CLAMP) has been set up under the EUREKA scheme to coordinate the commercial and technical expertise currently available in Europe. (author)

  19. Intraoperative Subcortical Electrical Mapping of the Optic Tract in Awake Surgery Using a Virtual Reality Headset.

    Science.gov (United States)

    Mazerand, Edouard; Le Renard, Marc; Hue, Sophie; Lemée, Jean-Michel; Klinger, Evelyne; Menei, Philippe

    2017-01-01

    Brain mapping during awake craniotomy is a well-known technique to preserve neurological functions, especially the language. It is still challenging to map the optic radiations due to the difficulty to test the visual field intraoperatively. To assess the visual field during awake craniotomy, we developed the Functions' Explorer based on a virtual reality headset (FEX-VRH). The impaired visual field of 10 patients was tested with automated perimetry (the gold standard examination) and the FEX-VRH. The proof-of-concept test was done during the surgery performed on a patient who was blind in his right eye and presenting with a left parietotemporal glioblastoma. The FEX-VRH was used intraoperatively, simultaneously with direct subcortical electrostimulation, allowing identification and preservation of the optic radiations. The FEX-VRH detected 9 of the 10 visual field defects found by automated perimetry. The patient who underwent an awake craniotomy with intraoperative mapping of the optic tract using the FEX-VRH had no permanent postoperative visual field defect. Intraoperative visual field assessment with the FEX-VRH during direct subcortical electrostimulation is a promising approach to mapping the optical radiations and preventing a permanent visual field defect during awake surgery for epilepsy or tumor. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Short-wavelength soft-x-ray laser pumped in double-pulse single-beam non-normal incidence

    International Nuclear Information System (INIS)

    Zimmer, D.; Ros, D.; Guilbaud, O.; Habib, J.; Kazamias, S.; Zielbauer, B.; Bagnoud, V.; Ecker, B.; Aurand, B.; Kuehl, T.; Hochhaus, D. C.; Neumayer, P.

    2010-01-01

    We demonstrated a 7.36 nm Ni-like samarium soft-x-ray laser, pumped by 36 J of a neodymium:glass chirped-pulse amplification laser. Double-pulse single-beam non-normal-incidence pumping was applied for efficient soft-x-ray laser generation. In this case, the applied technique included a single-optic focusing geometry for large beam diameters, a single-pass grating compressor, traveling-wave tuning capability, and an optimized high-energy laser double pulse. This scheme has the potential for even shorter-wavelength soft-x-ray laser pumping.

  1. Short wavelength lateral variability of lithospheric mantle beneath the Middle Atlas (Morocco) as recorded by mantle xenoliths

    Science.gov (United States)

    El Messbahi, Hicham; Bodinier, Jean-Louis; Vauchez, Alain; Dautria, Jean-Marie; Ouali, Houssa; Garrido, Carlos J.

    2015-05-01

    mountains results from the combination of different mechanisms and occurred in a piecewise fashion at a short wavelength scale.

  2. Complacency and Automation Bias in the Use of Imperfect Automation.

    Science.gov (United States)

    Wickens, Christopher D; Clegg, Benjamin A; Vieane, Alex Z; Sebok, Angelia L

    2015-08-01

    We examine the effects of two different kinds of decision-aiding automation errors on human-automation interaction (HAI), occurring at the first failure following repeated exposure to correctly functioning automation. The two errors are incorrect advice, triggering the automation bias, and missing advice, reflecting complacency. Contrasts between analogous automation errors in alerting systems, rather than decision aiding, have revealed that alerting false alarms are more problematic to HAI than alerting misses are. Prior research in decision aiding, although contrasting the two aiding errors (incorrect vs. missing), has confounded error expectancy. Participants performed an environmental process control simulation with and without decision aiding. For those with the aid, automation dependence was created through several trials of perfect aiding performance, and an unexpected automation error was then imposed in which automation was either gone (one group) or wrong (a second group). A control group received no automation support. The correct aid supported faster and more accurate diagnosis and lower workload. The aid failure degraded all three variables, but "automation wrong" had a much greater effect on accuracy, reflecting the automation bias, than did "automation gone," reflecting the impact of complacency. Some complacency was manifested for automation gone, by a longer latency and more modest reduction in accuracy. Automation wrong, creating the automation bias, appears to be a more problematic form of automation error than automation gone, reflecting complacency. Decision-aiding automation should indicate its lower degree of confidence in uncertain environments to avoid the automation bias. © 2015, Human Factors and Ergonomics Society.

  3. Microcomputer control of automated TLD reader

    International Nuclear Information System (INIS)

    Bjarland, Bert.

    1979-10-01

    The interfacing electronics, the control algorithms and the developed programs of a 6800 microcomputer controlled automated TLD reader are described. The TL reading system is implemented with a photomultiplier tube and a charge-to-pulse converter. The gain of the TL reading system is controlled through the use of a temperature compensated LED reference light source. Automatic compensation of PM tube dark current is optional. The short term stability of TL readings is better than 3 %. (author)

  4. Unveiling the Progenitors of Short-duration Gamma-ray Bursts

    Science.gov (United States)

    Fong, Wen-Fai

    2016-03-01

    Gamma-ray bursts (GRBs) are relativistic explosions which originate at cosmological distances, and are among the most luminous transients in the universe. Following the prompt gamma-ray emission, a fading synchrotron ``afterglow'' is detectable at lower energies. While long-duration GRBs (duration >2 sec) are linked to the deaths of massive stars, the progenitors of short-duration GRBs (duration black hole. Such merging systems are also important to understand because they are premier candidates for gravitational wave detections with current facilities and are likely sites of heavy element nucleosynthesis. The launch of NASA's Swift satellite in 2004, with its rapid multi-wavelength monitoring and localization capabilities, led to the first discoveries of short GRB afterglows and therefore robust associations to host galaxies. At a detection rate of roughly 10 events per year, the growing number of well-localized short GRBs has enabled comprehensive population studies of their afterglows and environments for the first time. In this talk, I describe my multi-wavelength observational campaign to address testable predictions for the progenitors of short GRBs. My work comprises several lines of independent evidence to demonstrate that short GRBs originate from the mergers of two compact objects, and also provides the first constraints on the explosion properties for a large sample of events. With the direct detection of gravitational waves from compact object mergers on the horizon, these studies provide necessary inputs to inform the next decade of joint electromagnetic-gravitational wave search strategies.

  5. The test beamline of the European Spallation Source - Instrumentation development and wavelength frame multiplication

    DEFF Research Database (Denmark)

    Woracek, R.; Hofmann, T.; Bulat, M.

    2016-01-01

    which, in contrast, are all providing short neutron pulses. In order to enable the development of methods and technology adapted to this novel type of source well in advance of the first instruments being constructed at ESS, a test beamline (TBL) was designed and built at the BER II research reactor...... wavelength band between 1.6 A and 10 A by a dedicated wavelength frame multiplication (WFM) chopper system. WFM is proposed for several ESS instruments to allow for flexible time-of-flight resolution. Hence, ESS will benefit from the TBL which offers unique possibilities for testing methods and components....... This article describes the main capabilities of the instrument, its performance as experimentally verified during the commissioning, and its relevance to currently starting ESS instrumentation projects....

  6. Highly accurate Michelson type wavelength meter that uses a rubidium stabilized 1560 nm diode laser as a wavelength reference

    International Nuclear Information System (INIS)

    Masuda, Shin; Kanoh, Eiji; Irisawa, Akiyoshi; Niki, Shoji

    2009-01-01

    We investigated the accuracy limitation of a wavelength meter installed in a vacuum chamber to enable us to develop a highly accurate meter based on a Michelson interferometer in 1550 nm optical communication bands. We found that an error of parts per million order could not be avoided using famous wavelength compensation equations. Chromatic dispersion of the refractive index in air can almost be disregarded when a 1560 nm wavelength produced by a rubidium (Rb) stabilized distributed feedback (DFB) diode laser is used as a reference wavelength. We describe a novel dual-wavelength self-calibration scheme that maintains high accuracy of the wavelength meter. The method uses the fundamental and second-harmonic wavelengths of an Rb-stabilized DFB diode laser. Consequently, a highly accurate Michelson type wavelength meter with an absolute accuracy of 5x10 -8 (10 MHz, 0.08 pm) over a wide wavelength range including optical communication bands was achieved without the need for a vacuum chamber.

  7. CONFIRMING THE PRIMARILY SMOOTH STRUCTURE OF THE VEGA DEBRIS DISK AT MILLIMETER WAVELENGTHS

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, A. Meredith; Plambeck, Richard; Chiang, Eugene [Department of Astronomy, University of California, Berkeley, CA 94720 (United States); Wilner, David J.; Andrews, Sean M. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Mason, Brian [National Radio Astronomy Observatory, 520 Edgemont Road, Charlottesville, VA 22903-2475 (United States); Carpenter, John M. [California Institute of Technology, Department of Astronomy, MC 105-24, Pasadena, CA 91125 (United States); Chiang, Hsin-Fang [Institute for Astronomy, University of Hawaii, 640 North Aohoku Place, Hilo, HI 96720 (United States); Williams, Jonathan P. [Institute for Astronomy, University of Hawaii, 2680 Woodlawn Drive, Honolulu, HI 96822 (United States); Hales, Antonio [Joint ALMA Observatory, Av. El Golf 40, Piso 18, Santiago (Chile); Su, Kate [Steward Observatory, University of Arizona, 933 North Cherry Avenue, Tucson, AZ 85721 (United States); Dicker, Simon; Korngut, Phil; Devlin, Mark, E-mail: mhughes@astro.berkeley.edu [Department of Physics and Astronomy, University of Pennsylvania, 209 South 33rd Street, Philadelphia, PA 19104 (United States)

    2012-05-01

    Clumpy structure in the debris disk around Vega has been previously reported at millimeter wavelengths and attributed to concentrations of dust grains trapped in resonances with an unseen planet. However, recent imaging at similar wavelengths with higher sensitivity has disputed the observed structure. We present three new millimeter-wavelength observations that help to resolve the puzzling and contradictory observations. We have observed the Vega system with the Submillimeter Array (SMA) at a wavelength of 880 {mu}m and an angular resolution of 5''; with the Combined Array for Research in Millimeter-wave Astronomy (CARMA) at a wavelength of 1.3 mm and an angular resolution of 5''; and with the Green Bank Telescope (GBT) at a wavelength of 3.3 mm and angular resolution of 10''. Despite high sensitivity and short baselines, we do not detect the Vega debris disk in either of the interferometric data sets (SMA and CARMA), which should be sensitive at high significance to clumpy structure based on previously reported observations. We obtain a marginal (3{sigma}) detection of disk emission in the GBT data; the spatial distribution of the emission is not well constrained. We analyze the observations in the context of several different models, demonstrating that the observations are consistent with a smooth, broad, axisymmetric disk with inner radius 20-100 AU and width {approx}> 50 AU. The interferometric data require that at least half of the 860 {mu}m emission detected by previous single-dish observations with the James Clerk Maxwell Telescope be distributed axisymmetrically, ruling out strong contributions from flux concentrations on spatial scales of {approx}<100 AU. These observations support recent results from the Plateau de Bure Interferometer indicating that previous detections of clumpy structure in the Vega debris disk were spurious.

  8. CONFIRMING THE PRIMARILY SMOOTH STRUCTURE OF THE VEGA DEBRIS DISK AT MILLIMETER WAVELENGTHS

    International Nuclear Information System (INIS)

    Hughes, A. Meredith; Plambeck, Richard; Chiang, Eugene; Wilner, David J.; Andrews, Sean M.; Mason, Brian; Carpenter, John M.; Chiang, Hsin-Fang; Williams, Jonathan P.; Hales, Antonio; Su, Kate; Dicker, Simon; Korngut, Phil; Devlin, Mark

    2012-01-01

    Clumpy structure in the debris disk around Vega has been previously reported at millimeter wavelengths and attributed to concentrations of dust grains trapped in resonances with an unseen planet. However, recent imaging at similar wavelengths with higher sensitivity has disputed the observed structure. We present three new millimeter-wavelength observations that help to resolve the puzzling and contradictory observations. We have observed the Vega system with the Submillimeter Array (SMA) at a wavelength of 880 μm and an angular resolution of 5''; with the Combined Array for Research in Millimeter-wave Astronomy (CARMA) at a wavelength of 1.3 mm and an angular resolution of 5''; and with the Green Bank Telescope (GBT) at a wavelength of 3.3 mm and angular resolution of 10''. Despite high sensitivity and short baselines, we do not detect the Vega debris disk in either of the interferometric data sets (SMA and CARMA), which should be sensitive at high significance to clumpy structure based on previously reported observations. We obtain a marginal (3σ) detection of disk emission in the GBT data; the spatial distribution of the emission is not well constrained. We analyze the observations in the context of several different models, demonstrating that the observations are consistent with a smooth, broad, axisymmetric disk with inner radius 20-100 AU and width ∼> 50 AU. The interferometric data require that at least half of the 860 μm emission detected by previous single-dish observations with the James Clerk Maxwell Telescope be distributed axisymmetrically, ruling out strong contributions from flux concentrations on spatial scales of ∼<100 AU. These observations support recent results from the Plateau de Bure Interferometer indicating that previous detections of clumpy structure in the Vega debris disk were spurious.

  9. A recent investigation of neutron total cross section of zirconium in the wavelength range (0.1-1.25) Ao

    International Nuclear Information System (INIS)

    Abu El-Ela, M.A.

    1996-01-01

    The neutron total cross section of zirconium has been investigated in the neutron wavelength range (0.1 -1.52) A o by using slow neutron time of flight spectrometer, installed in front of the horizontal channel No.6 of the ETRR-1 reactor (2MW). The results have showed that the neutrons with short wavelength (0.1 - 0.76) A o cannot interact with the crystal structure while it can interact with the free bound atom to give the value (6.2 +0.1) barns for the potential scattering cross section or (the scattering length = 6.2 fermi)). The present measured value is in good agreement with the international published values by different technique. The neutrons with longer wavelength (0.76 - 1.52) A o have showed dependence of the total cross section on the neutron wavelength. Such dependence between the total cross section and the neutron wavelength can not be observed in the reported previous measurements, which can be attributed to the limited number of the measured values. 4 figs

  10. EFFECTS OF LIGHT WAVELENGTHS AND COHERENCE ON BASIDIOSPORES GERMINATION

    Directory of Open Access Journals (Sweden)

    Natalia Poyedinok

    2015-02-01

    Full Text Available The effects of light wavelengths and coherence on basidiospore germination of Agaricus bisporus, Flammulina velutipes, Ganoderma applanatum, Ganoderma lucidum, Hericium erinaceus, Lentinus edodes and Pleurotus ostreatus have been studied. Short-term low-intensity irradiation by coherent (laser light wavelength 488.0 nm and 632.8 nm at doses 45 and 230 mJ/cm2 has significantly increased the number of germinated basidiospores. It has established that there are differences in the photosensitivity not only between species but also between strains. Spores irradiation by 514.5 nm light has been either neutral or inhibitory. A comparative analysis of basidiospores sensitivity to laser and LED light has also been conducted. To stimulate germination of basidiospores and growth of monokaryons the most suitable solution was to use red coherent and incoherent light of 632.8 nm and 660,0 nm for A. bisporus, G. applanatum and P. ostreatus, red and blue coherent light of 632.8 nm and 488,0 nm for F. velutipes, and both red and blue laser and LED light G. lucidum and H. erinaceus and for L. edodes. No essential difference of a continuous wave mode and intermittent mode light effect at the same doses and wavelength on spore germination were revealed. Light influence has reduced germination time and formation of aerial mycelium on agar medium as compared to the original value and increased the growth rate of monosporous isolates. Characterization of basidiospores photosensitivity and development of environmentally friendly stimulating methods of their germination is important for creating highly effective technologies of mushrooms selection and cultivation.

  11. PHOTOGRAMMETRY-BASED AUTOMATED MEASUREMENTS FOR TOOTH SHAPE AND OCCLUSION ANALYSIS

    Directory of Open Access Journals (Sweden)

    V. A. Knyaz

    2016-06-01

    Full Text Available Tooth measurements (odontometry are performed for various scientific and practical applications, including dentistry. Present-day techniques are being increasingly based on 3D model use that provides wider prospects in comparison to measurements on real objects: teeth or their plaster copies. The main advantages emerge through application of new measurement methods which provide the needed degree of non-invasiveness, precision, convenience and details. Tooth measurements have been always regarded as a time-consuming research, even more so with use of new methods due to their wider opportunities. This is where automation becomes essential for further development and implication of measurement techniques. In our research automation in obtaining 3D models and automation of measurements provided essential data that was analysed to suggest recommendations for tooth preparation – one of the most responsible clinical procedures in prosthetic dentistry – within a comparatively short period of time. The original photogrammetric 3D reconstruction system allows to generate 3D models of dental arches, reproduce their closure, or occlusion, and to perform a set of standard measurement in automated mode.

  12. Photogrammetry-Based Automated Measurements for Tooth Shape and Occlusion Analysis

    Science.gov (United States)

    Knyaz, V. A.; Gaboutchian, A. V.

    2016-06-01

    Tooth measurements (odontometry) are performed for various scientific and practical applications, including dentistry. Present-day techniques are being increasingly based on 3D model use that provides wider prospects in comparison to measurements on real objects: teeth or their plaster copies. The main advantages emerge through application of new measurement methods which provide the needed degree of non-invasiveness, precision, convenience and details. Tooth measurements have been always regarded as a time-consuming research, even more so with use of new methods due to their wider opportunities. This is where automation becomes essential for further development and implication of measurement techniques. In our research automation in obtaining 3D models and automation of measurements provided essential data that was analysed to suggest recommendations for tooth preparation - one of the most responsible clinical procedures in prosthetic dentistry - within a comparatively short period of time. The original photogrammetric 3D reconstruction system allows to generate 3D models of dental arches, reproduce their closure, or occlusion, and to perform a set of standard measurement in automated mode.

  13. Improving the driver-automation interaction: an approach using automation uncertainty.

    Science.gov (United States)

    Beller, Johannes; Heesen, Matthias; Vollrath, Mark

    2013-12-01

    The aim of this study was to evaluate whether communicating automation uncertainty improves the driver-automation interaction. A false system understanding of infallibility may provoke automation misuse and can lead to severe consequences in case of automation failure. The presentation of automation uncertainty may prevent this false system understanding and, as was shown by previous studies, may have numerous benefits. Few studies, however, have clearly shown the potential of communicating uncertainty information in driving. The current study fills this gap. We conducted a driving simulator experiment, varying the presented uncertainty information between participants (no uncertainty information vs. uncertainty information) and the automation reliability (high vs.low) within participants. Participants interacted with a highly automated driving system while engaging in secondary tasks and were required to cooperate with the automation to drive safely. Quantile regressions and multilevel modeling showed that the presentation of uncertainty information increases the time to collision in the case of automation failure. Furthermore, the data indicated improved situation awareness and better knowledge of fallibility for the experimental group. Consequently, the automation with the uncertainty symbol received higher trust ratings and increased acceptance. The presentation of automation uncertaintythrough a symbol improves overall driver-automation cooperation. Most automated systems in driving could benefit from displaying reliability information. This display might improve the acceptance of fallible systems and further enhances driver-automation cooperation.

  14. Making Displaced Holograms At Two Wavelengths

    Science.gov (United States)

    Witherow, William K.; Ecker, Andreas

    1989-01-01

    Two-wavelength holographic system augmented with pair of prisms to introduce small separation between holograms formed simultaneously at two wavelengths on holographic plate. Principal use in study of flows. Gradients in index of refraction of fluid caused by variations in temperature, concentration, or both. Holography at one wavelength cannot be used to distinguish between two types of variations. Difference between spacings of fringes in photographs reconstructed from holograms taken simultaneously at two different wavelengths manipulated mathematically to determine type of variation.

  15. Certain features of FELs with short bunches

    International Nuclear Information System (INIS)

    Lebedev, A.N.

    2006-01-01

    The report is devoted to physics of free electron lasers operating in the short-wave domain where the bunch length could be less than the undulator length in the proper frame. Then the current component of the signal is locked within the bunch as in a cavity, while the electromagnetic component propagates freely. In contrast with gyrotrons where this regime can be of interest only for wavelengths comparable with the bunch length, we consider short waves in a bunch of arbitrary profile. Both amplification of an external harmonic signal and SASE regime, i.e. selective amplification of proper noises, are investigated

  16. Comparison of different Aethalometer correction schemes and a reference multi-wavelength absorption technique for ambient aerosol data

    Science.gov (United States)

    Saturno, Jorge; Pöhlker, Christopher; Massabò, Dario; Brito, Joel; Carbone, Samara; Cheng, Yafang; Chi, Xuguang; Ditas, Florian; Hrabě de Angelis, Isabella; Morán-Zuloaga, Daniel; Pöhlker, Mira L.; Rizzo, Luciana V.; Walter, David; Wang, Qiaoqiao; Artaxo, Paulo; Prati, Paolo; Andreae, Meinrat O.

    2017-08-01

    Deriving absorption coefficients from Aethalometer attenuation data requires different corrections to compensate for artifacts related to filter-loading effects, scattering by filter fibers, and scattering by aerosol particles. In this study, two different correction schemes were applied to seven-wavelength Aethalometer data, using multi-angle absorption photometer (MAAP) data as a reference absorption measurement at 637 nm. The compensation algorithms were compared to five-wavelength offline absorption measurements obtained with a multi-wavelength absorbance analyzer (MWAA), which serves as a multiple-wavelength reference measurement. The online measurements took place in the Amazon rainforest, from the wet-to-dry transition season to the dry season (June-September 2014). The mean absorption coefficient (at 637 nm) during this period was 1.8 ± 2.1 Mm-1, with a maximum of 15.9 Mm-1. Under these conditions, the filter-loading compensation was negligible. One of the correction schemes was found to artificially increase the short-wavelength absorption coefficients. It was found that accounting for the aerosol optical properties in the scattering compensation significantly affects the absorption Ångström exponent (åABS) retrievals. Proper Aethalometer data compensation schemes are crucial to retrieve the correct åABS, which is commonly implemented in brown carbon contribution calculations. Additionally, we found that the wavelength dependence of uncompensated Aethalometer attenuation data significantly correlates with the åABS retrieved from offline MWAA measurements.

  17. Wavelength dependence of interstellar polarization

    International Nuclear Information System (INIS)

    Mavko, G.E.

    1974-01-01

    The wavelength dependence of interstellar polarization was measured for twelve stars in three regions of the Milky Way. A 120A bandpass was used to measure the polarization at a maximum of sixteen wavelengths evenly spaced between 2.78μ -1 (3600A) and 1.28μ -1 (7800A). For such a wide wavelength range, the wavelength resolution is superior to that of any previously reported polarization measurements. The new scanning polarimeter built by W. A. Hiltner of the University of Michigan was used for the observations. Very broad structure was found in the wavelength dependence of the polarization. Extensive investigations were carried out to show that the structure was not caused by instrumental effects. The broad structure observed is shown to be in agreement with concurrent extinction measurements for the same stars. Also, the observed structure is of the type predicted when a homogeneous silicate grain model is fitted to the observed extinction. The results are in agreement with the hypothesis that the very broad band structure seen in the extinction is produced by the grains. (Diss. Abstr. Int., B)

  18. Working together on automated vehicle guidance AVG : preliminary business plan, abridged version.

    NARCIS (Netherlands)

    Awareness (ed.)

    1998-01-01

    This plan describes the questions which will have to be answered in the short term, and the action which need to be taken in a phased and structured manner to gain insight into the potential of automated vehicle guidance (AVG).

  19. System of automated processing of radionuclide investigations (SAPRI-01) in clinical practice

    International Nuclear Information System (INIS)

    Sivachenko, T.P.; Mechev, D.S.; Krupka, I.N.

    1988-01-01

    The author described the results of clinical testing of a system SAPRI-01 designed for automated collection, storage and processing of data on radionuclide investigations. He gave examples of automated processing of RCG and the results of positive scintigraphy of tumors of different sites using 67 Ga-citrate and 99m Tc pertechnetate in statistical and dynamic investigations. Short-comings and ways for updating 4 the system during its serial production were pointed out. The introduction of the system into clinical practice on a wide scale was shown to hold promise

  20. Topology optimised wavelength dependent splitters

    DEFF Research Database (Denmark)

    Hede, K. K.; Burgos Leon, J.; Frandsen, Lars Hagedorn

    A photonic crystal wavelength dependent splitter has been constructed by utilising topology optimisation1. The splitter has been fabricated in a silicon-on-insulator material (Fig. 1). The topology optimised wavelength dependent splitter demonstrates promising 3D FDTD simulation results....... This complex photonic crystal structure is very sensitive against small fabrication variations from the expected topology optimised design. A wavelength dependent splitter is an important basic building block for high-performance nanophotonic circuits. 1J. S. Jensen and O. Sigmund, App. Phys. Lett. 84, 2022...

  1. Effective wavelength calibration for moire fringe projection

    International Nuclear Information System (INIS)

    Purcell, Daryl; Davies, Angela; Farahi, Faramarz

    2006-01-01

    The fringe patterns seen when using moire instruments are similar to the patterns seen in traditional interferometry but differ in the spacing between consecutive fringes. In traditional interferometry, the spacing is constant and related to the wavelength of the source. In moire fringe projection, the spacing (the effective wavelength) may not be constant over the field of view and the spacing depends on the system geometry. In these cases, using a constant effective wavelength over the field of view causes inaccurate surface height measurements. We examine the calibration process of the moirefringe projection measurement, which takes this varying wavelength into account to produce a pixel-by-pixel wavelength map. The wavelength calibration procedure is to move the object in the out-of-plane direction a known distance until every pixel intensity value goes through at least one cycle. A sinusoidal function is then fit to the data to extract the effective wavelength pixel by pixel, yielding an effective wavelength map. A calibrated step height was used to validate the effective wavelength map with results within 1% of the nominal value of the step height. The error sources that contributed to the uncertainty in determining the height of the artifact are also investigated

  2. Comparison of XH2O Retrieved from GOSAT Short-Wavelength Infrared Spectra with Observations from the TCCON Network

    Directory of Open Access Journals (Sweden)

    Eric Dupuy

    2016-05-01

    Full Text Available Understanding the atmospheric distribution of water (H 2 O is crucial for global warming studies and climate change mitigation. In this context, reliable satellite data are extremely valuable for their global and continuous coverage, once their quality has been assessed. Short-wavelength infrared spectra are acquired by the Thermal And Near-infrared Sensor for carbon Observation-Fourier Transform Spectrometer (TANSO-FTS aboard the Greenhouse gases Observing Satellite (GOSAT. From these, column-averaged dry-air mole fractions of carbon dioxide, methane and water vapor (XH 2 O have been retrieved at the National Institute for Environmental Studies (NIES, Japan and are available as a Level 2 research product. We compare the NIES XH 2 O data, Version 02.21, with retrievals from the ground-based Total Carbon Column Observing Network (TCCON, Version GGG2014. The datasets are in good overall agreement, with GOSAT data showing a slight global low bias of −3.1% ± 24.0%, good consistency over different locations (station bias of −1.53% ± 10.35% and reasonable correlation with TCCON (R = 0.89. We identified two potential sources of discrepancy between the NIES and TCCON retrievals over land. While the TCCON XH 2 O amounts can reach 6000–7000 ppm when the atmospheric water content is high, the correlated NIES values do not exceed 5500 ppm. This could be due to a dry bias of TANSO-FTS in situations of high humidity and aerosol content. We also determined that the GOSAT-TCCON differences directly depend on the altitude difference between the TANSO-FTS footprint and the TCCON site. Further analysis will account for these biases, but the NIES V02.21 XH 2 O product, after public release, can already be useful for water cycle studies.

  3. Automated translating beam profiler for in situ laser beam spot-size and focal position measurements

    Science.gov (United States)

    Keaveney, James

    2018-03-01

    We present a simple and convenient, high-resolution solution for automated laser-beam profiling with axial translation. The device is based on a Raspberry Pi computer, Pi Noir CMOS camera, stepper motor, and commercial translation stage. We also provide software to run the device. The CMOS sensor is sensitive over a large wavelength range between 300 and 1100 nm and can be translated over 25 mm along the beam axis. The sensor head can be reversed without changing its axial position, allowing for a quantitative estimate of beam overlap with counter-propagating laser beams. Although not limited to this application, the intended use for this device is the automated measurement of the focal position and spot-size of a Gaussian laser beam. We present example data of one such measurement to illustrate device performance.

  4. Optimal issuing of perishables with a short fixed shelf life

    NARCIS (Netherlands)

    Haijema, R.

    2011-01-01

    The management of inventories of perishable products with a short maximal shelf life takes a good issuing policy next to a good ordering policy. Ordering policies of non-perishables are well studied in literature and implemented in Automated Store Ordering (ASO) systems and Computer Assisted

  5. A new software routine that automates the fitting of protein X-ray crystallographic electron-density maps.

    Science.gov (United States)

    Levitt, D G

    2001-07-01

    The classical approach to building the amino-acid residues into the initial electron-density map requires days to weeks of a skilled investigator's time. Automating this procedure should not only save time, but has the potential to provide a more accurate starting model for input to refinement programs. The new software routine MAID builds the protein structure into the electron-density map in a series of sequential steps. The first step is the fitting of the secondary alpha-helix and beta-sheet structures. These 'fits' are then used to determine the local amino-acid sequence assignment. These assigned fits are then extended through the loop regions and fused with the neighboring sheet or helix. The program was tested on the unaveraged 2.5 A selenomethionine multiple-wavelength anomalous dispersion (SMAD) electron-density map that was originally used to solve the structure of the 291-residue protein human heart short-chain L-3-hydroxyacyl-CoA dehydrogenase (SHAD). Inputting just the map density and the amino-acid sequence, MAID fitted 80% of the residues with an r.m.s.d. error of 0.43 A for the main-chain atoms and 1.0 A for all atoms without any user intervention. When tested on a higher quality 1.9 A SMAD map, MAID correctly fitted 100% (418) of the residues. A major advantage of the MAID fitting procedure is that it maintains ideal bond lengths and angles and constrains phi/psi angles to the appropriate Ramachandran regions. Recycling the output of this new routine through a partial structure-refinement program may have the potential to completely automate the fitting of electron-density maps.

  6. Aviation Safety: Modeling and Analyzing Complex Interactions between Humans and Automated Systems

    Science.gov (United States)

    Rungta, Neha; Brat, Guillaume; Clancey, William J.; Linde, Charlotte; Raimondi, Franco; Seah, Chin; Shafto, Michael

    2013-01-01

    The on-going transformation from the current US Air Traffic System (ATS) to the Next Generation Air Traffic System (NextGen) will force the introduction of new automated systems and most likely will cause automation to migrate from ground to air. This will yield new function allocations between humans and automation and therefore change the roles and responsibilities in the ATS. Yet, safety in NextGen is required to be at least as good as in the current system. We therefore need techniques to evaluate the safety of the interactions between humans and automation. We think that current human factor studies and simulation-based techniques will fall short in front of the ATS complexity, and that we need to add more automated techniques to simulations, such as model checking, which offers exhaustive coverage of the non-deterministic behaviors in nominal and off-nominal scenarios. In this work, we present a verification approach based both on simulations and on model checking for evaluating the roles and responsibilities of humans and automation. Models are created using Brahms (a multi-agent framework) and we show that the traditional Brahms simulations can be integrated with automated exploration techniques based on model checking, thus offering a complete exploration of the behavioral space of the scenario. Our formal analysis supports the notion of beliefs and probabilities to reason about human behavior. We demonstrate the technique with the Ueberligen accident since it exemplifies authority problems when receiving conflicting advices from human and automated systems.

  7. Automated Identification of Coronal Holes from Synoptic EUV Maps

    Science.gov (United States)

    Hamada, Amr; Asikainen, Timo; Virtanen, Ilpo; Mursula, Kalevi

    2018-04-01

    Coronal holes (CHs) are regions of open magnetic field lines in the solar corona and the source of the fast solar wind. Understanding the evolution of coronal holes is critical for solar magnetism as well as for accurate space weather forecasts. We study the extreme ultraviolet (EUV) synoptic maps at three wavelengths (195 Å/193 Å, 171 Å and 304 Å) measured by the Solar and Heliospheric Observatory/Extreme Ultraviolet Imaging Telescope (SOHO/EIT) and the Solar Dynamics Observatory/Atmospheric Imaging Assembly (SDO/AIA) instruments. The two datasets are first homogenized by scaling the SDO/AIA data to the SOHO/EIT level by means of histogram equalization. We then develop a novel automated method to identify CHs from these homogenized maps by determining the intensity threshold of CH regions separately for each synoptic map. This is done by identifying the best location and size of an image segment, which optimally contains portions of coronal holes and the surrounding quiet Sun allowing us to detect the momentary intensity threshold. Our method is thus able to adjust itself to the changing scale size of coronal holes and to temporally varying intensities. To make full use of the information in the three wavelengths we construct a composite CH distribution, which is more robust than distributions based on one wavelength. Using the composite CH dataset we discuss the temporal evolution of CHs during the Solar Cycles 23 and 24.

  8. Low cost automation

    International Nuclear Information System (INIS)

    1987-03-01

    This book indicates method of building of automation plan, design of automation facilities, automation and CHIP process like basics of cutting, NC processing machine and CHIP handling, automation unit, such as drilling unit, tapping unit, boring unit, milling unit and slide unit, application of oil pressure on characteristics and basic oil pressure circuit, application of pneumatic, automation kinds and application of process, assembly, transportation, automatic machine and factory automation.

  9. Comparison of different Aethalometer correction schemes and a reference multi-wavelength absorption technique for ambient aerosol data

    Directory of Open Access Journals (Sweden)

    J. Saturno

    2017-08-01

    Full Text Available Deriving absorption coefficients from Aethalometer attenuation data requires different corrections to compensate for artifacts related to filter-loading effects, scattering by filter fibers, and scattering by aerosol particles. In this study, two different correction schemes were applied to seven-wavelength Aethalometer data, using multi-angle absorption photometer (MAAP data as a reference absorption measurement at 637 nm. The compensation algorithms were compared to five-wavelength offline absorption measurements obtained with a multi-wavelength absorbance analyzer (MWAA, which serves as a multiple-wavelength reference measurement. The online measurements took place in the Amazon rainforest, from the wet-to-dry transition season to the dry season (June–September 2014. The mean absorption coefficient (at 637 nm during this period was 1.8 ± 2.1 Mm−1, with a maximum of 15.9 Mm−1. Under these conditions, the filter-loading compensation was negligible. One of the correction schemes was found to artificially increase the short-wavelength absorption coefficients. It was found that accounting for the aerosol optical properties in the scattering compensation significantly affects the absorption Ångström exponent (åABS retrievals. Proper Aethalometer data compensation schemes are crucial to retrieve the correct åABS, which is commonly implemented in brown carbon contribution calculations. Additionally, we found that the wavelength dependence of uncompensated Aethalometer attenuation data significantly correlates with the åABS retrieved from offline MWAA measurements.

  10. Compactly packaged monolithic four-wavelength VCSEL array with 100-GHz wavelength spacing for future-proof mobile fronthaul transport.

    Science.gov (United States)

    Lee, Eun-Gu; Mun, Sil-Gu; Lee, Sang Soo; Lee, Jyung Chan; Lee, Jong Hyun

    2015-01-12

    We report a cost-effective transmitter optical sub-assembly using a monolithic four-wavelength vertical-cavity surface-emitting laser (VCSEL) array with 100-GHz wavelength spacing for future-proof mobile fronthaul transport using the data rate of common public radio interface option 6. The wavelength spacing is achieved using selectively etched cavity control layers and fine current adjustment. The differences in operating current and output power for maintaining the wavelength spacing of four VCSELs are fiber without any dispersion-compensation techniques.

  11. AWG Filter for Wavelength Interrogator

    Science.gov (United States)

    Black, Richard J. (Inventor); Costa, Joannes M. (Inventor); Faridian, Fereydoun (Inventor); Moslehi, Behzad (Inventor); Sotoudeh, Vahid (Inventor)

    2015-01-01

    A wavelength interrogator is coupled to a circulator which couples optical energy from a broadband source to an optical fiber having a plurality of sensors, each sensor reflecting optical energy at a unique wavelength and directing the reflected optical energy to an AWG. The AWG has a detector coupled to each output, and the reflected optical energy from each grating is coupled to the skirt edge response of the AWG such that the adjacent channel responses form a complementary pair response. The complementary pair response is used to convert an AWG skirt response to a wavelength.

  12. Glaucomatous patterns in Frequency Doubling Technology (FDT) perimetry data identified by unsupervised machine learning classifiers.

    Science.gov (United States)

    Bowd, Christopher; Weinreb, Robert N; Balasubramanian, Madhusudhanan; Lee, Intae; Jang, Giljin; Yousefi, Siamak; Zangwill, Linda M; Medeiros, Felipe A; Girkin, Christopher A; Liebmann, Jeffrey M; Goldbaum, Michael H

    2014-01-01

    The variational Bayesian independent component analysis-mixture model (VIM), an unsupervised machine-learning classifier, was used to automatically separate Matrix Frequency Doubling Technology (FDT) perimetry data into clusters of healthy and glaucomatous eyes, and to identify axes representing statistically independent patterns of defect in the glaucoma clusters. FDT measurements were obtained from 1,190 eyes with normal FDT results and 786 eyes with abnormal FDT results from the UCSD-based Diagnostic Innovations in Glaucoma Study (DIGS) and African Descent and Glaucoma Evaluation Study (ADAGES). For all eyes, VIM input was 52 threshold test points from the 24-2 test pattern, plus age. FDT mean deviation was -1.00 dB (S.D. = 2.80 dB) and -5.57 dB (S.D. = 5.09 dB) in FDT-normal eyes and FDT-abnormal eyes, respectively (p<0.001). VIM identified meaningful clusters of FDT data and positioned a set of statistically independent axes through the mean of each cluster. The optimal VIM model separated the FDT fields into 3 clusters. Cluster N contained primarily normal fields (1109/1190, specificity 93.1%) and clusters G1 and G2 combined, contained primarily abnormal fields (651/786, sensitivity 82.8%). For clusters G1 and G2 the optimal number of axes were 2 and 5, respectively. Patterns automatically generated along axes within the glaucoma clusters were similar to those known to be indicative of glaucoma. Fields located farther from the normal mean on each glaucoma axis showed increasing field defect severity. VIM successfully separated FDT fields from healthy and glaucoma eyes without a priori information about class membership, and identified familiar glaucomatous patterns of loss.

  13. Extended wavelength InGaAs SWIR FPAs with high performance

    Science.gov (United States)

    Li, Xue; Li, Tao; Yu, Chunlei; Tang, Hengjing; Deng, Shuangyan; Shao, Xiumei; Zhang, Yonggang; Gong, Haimei

    2017-09-01

    The extended InGaAs short wavelength infrared (SWIR) detector covers 1.0-2.5 μm wavelength, which plays an important role in weather forecast, resource observation, low light level systems, and astronomical observation and so on. In order to fabricate the high performance extended InGaAs detector, materials structure and parameters were characterized with Scanning Capacitance Microscopy (SCM), Scanning Spreading Resistance Microscopy (SSRM), the spreading of minority carriers and lattice quality were obtained. Mesa etching process, etching damage restoration technique and low temperature passivation technique were used in the fabrication of the extended InGaAs detector. The improvement of material structure and device process was studied by fabricating and measuring different perimeter-to-area (P/A) photodiodes and singledevice, respectively. The dark current density of the extended InGaAs detector obviously was reduced, about 2 nA/cm2 at 170 K. The 512×256 FPAs were fabricated, the peak detectivity and the quantum efficiency of which are 5×1011 cmHz1/2/W and 80%, respectively. The staring image yielded of the 512×256 FPAs is shown, which demonstrates very good imaging quality.

  14. Short-Term Change Detection in Wetlands Using Sentinel-1 Time Series

    DEFF Research Database (Denmark)

    Muro, Javier; Canty, Morton; Conradsen, Knut

    2016-01-01

    Automated monitoring systems that can capture wetlands’ high spatial and temporal variability are essential for their management. SAR-based change detection approaches offer a great opportunity to enhance our understanding of complex and dynamic ecosystems. We test a recently-developed time serie...... certain landscape changes are detected only by either the Landsat-based or the S1-omnibus method. The S1-omnibus method shows a great potential for an automated monitoring of short time changes and accurate delineation of areas of high variability and of slow and gradual changes....

  15. Passively synchronized dual-wavelength Q-switched lasers

    DEFF Research Database (Denmark)

    Janousek, Jiri; Tidemand-Lichtenberg, Peter; Mortensen, Jesper Liltorp

    We present a simple and efficient way of generating synchronized Q-switched pulses at wavelengths hundreds of nanometers apart. This principle can result in new pulsed all-solid-state light sources at new wavelengths based on SFG.......We present a simple and efficient way of generating synchronized Q-switched pulses at wavelengths hundreds of nanometers apart. This principle can result in new pulsed all-solid-state light sources at new wavelengths based on SFG....

  16. Autonomy and Automation

    Science.gov (United States)

    Shively, Jay

    2017-01-01

    A significant level of debate and confusion has surrounded the meaning of the terms autonomy and automation. Automation is a multi-dimensional concept, and we propose that Remotely Piloted Aircraft Systems (RPAS) automation should be described with reference to the specific system and task that has been automated, the context in which the automation functions, and other relevant dimensions. In this paper, we present definitions of automation, pilot in the loop, pilot on the loop and pilot out of the loop. We further propose that in future, the International Civil Aviation Organization (ICAO) RPAS Panel avoids the use of the terms autonomy and autonomous when referring to automated systems on board RPA. Work Group 7 proposes to develop, in consultation with other workgroups, a taxonomy of Levels of Automation for RPAS.

  17. Decision Making In A High-Tech World: Automation Bias and Countermeasures

    Science.gov (United States)

    Mosier, Kathleen L.; Skitka, Linda J.; Burdick, Mark R.; Heers, Susan T.; Rosekind, Mark R. (Technical Monitor)

    1996-01-01

    Automated decision aids and decision support systems have become essential tools in many high-tech environments. In aviation, for example, flight management systems computers not only fly the aircraft, but also calculate fuel efficient paths, detect and diagnose system malfunctions and abnormalities, and recommend or carry out decisions. Air Traffic Controllers will soon be utilizing decision support tools to help them predict and detect potential conflicts and to generate clearances. Other fields as disparate as nuclear power plants and medical diagnostics are similarly becoming more and more automated. Ideally, the combination of human decision maker and automated decision aid should result in a high-performing team, maximizing the advantages of additional cognitive and observational power in the decision-making process. In reality, however, the presence of these aids often short-circuits the way that even very experienced decision makers have traditionally handled tasks and made decisions, and introduces opportunities for new decision heuristics and biases. Results of recent research investigating the use of automated aids have indicated the presence of automation bias, that is, errors made when decision makers rely on automated cues as a heuristic replacement for vigilant information seeking and processing. Automation commission errors, i.e., errors made when decision makers inappropriately follow an automated directive, or automation omission errors, i.e., errors made when humans fail to take action or notice a problem because an automated aid fails to inform them, can result from this tendency. Evidence of the tendency to make automation-related omission and commission errors has been found in pilot self reports, in studies using pilots in flight simulations, and in non-flight decision making contexts with student samples. Considerable research has found that increasing social accountability can successfully ameliorate a broad array of cognitive biases and

  18. Design and analysis of InN - In0.25Ga0.75N single quantum well laser for short distance communication wavelength

    Science.gov (United States)

    Polash, Md. Mobarak Hossain; Alam, M. Shah; Biswas, Saumya

    2018-03-01

    A single quantum well semiconductor laser based on wurtzite-nitride is designed and analyzed for short distance communication wavelength (at around 1300 nm). The laser structure has 12 Å well layer of InN, 15 Å barrier layer of In0.25Ga0.75N, and 54 Å separate confinement heterostructure layer of GaN. To calculate the electronic characteristics of the structure, a self-consistent method is used where Hamiltonian with effective mass approximation is solved for conduction band while six-bands Hamiltonian matrix with k · p formalism including the polarization effect, valence-band mixing effect, and strain effect is solved for valence band. The interband optical transition elements, optical gain, differential gain, radiative current density, spontaneous emission rate, and threshold characteristics have been calculated. The wave function overlap integral is found to be 45.93% for TE-polarized structure. Also, the spontaneous emission rate is found to be 6.57 × 1027 s - 1 cm - 3 eV - 1 at 1288.21 nm with the carrier density of 5 × 1019 cm - 3. Furthermore, the radiative current density and the radiative recombination rate are found to be 121.92 A cm - 2 and 6.35 × 1027 s - 1 cm - 3, respectively, while the TE-polarized optical gain of the structure is 3872.1 cm - 1 at 1301.7 nm.

  19. Photoreceptor atrophy in acute zonal occult outer retinopathy

    DEFF Research Database (Denmark)

    Zibrandtsen, N.; Munch, I.C.; Klemp, K.

    2008-01-01

    appearance were examined using optical coherence tomography (OCT), automated perimetry and electroretinography (ERG). RESULTS: Both patients demonstrated photoreceptor atrophy corresponding to partial or complete scotomata with reduced or extinct electroretinographic responses. Attenuation or complete loss...... of all the segments composing the photoreceptor layer was found by OCT. Full-field ERG revealed affection of the 30 Hz flicker responses and subnormal photopic responses in both patients and subnormal scotopic responses in case 1. Multifocal electroretinography (mERG) revealed localized outer retinal...

  20. Photoreceptor atrophy in acute zonal occult outer retinopathy

    DEFF Research Database (Denmark)

    Zibrandtsen, N.; Munch, I.C.; Klemp, K.

    2008-01-01

    examined using optical coherence tomography (OCT), automated perimetry and electroretinography (ERG). Both patients demonstrated photoreceptor atrophy corresponding to partial or complete scotomata with reduced or extinct electroretinographic responses. Attenuation or complete loss of all the segments...... composing the photoreceptor layer was found by OCT. Full-field ERG revealed affection of the 30 Hz flicker responses and subnormal photopic responses in both patients and subnormal scotopic responses in case 1. Multifocal electroretinography (mERG) revealed localized outer retinal dysfunction. The field...

  1. Automated quantitative analysis of in-situ NaI measured spectra in the marine environment using a wavelet-based smoothing technique

    International Nuclear Information System (INIS)

    Tsabaris, Christos; Prospathopoulos, Aristides

    2011-01-01

    An algorithm for automated analysis of in-situ NaI γ-ray spectra in the marine environment is presented. A standard wavelet denoising technique is implemented for obtaining a smoothed spectrum, while the stability of the energy spectrum is achieved by taking advantage of the permanent presence of two energy lines in the marine environment. The automated analysis provides peak detection, net area calculation, energy autocalibration, radionuclide identification and activity calculation. The results of the algorithm performance, presented for two different cases, show that analysis of short-term spectra with poor statistical information is considerably improved and that incorporation of further advancements could allow the use of the algorithm in early-warning marine radioactivity systems. - Highlights: → Algorithm for automated analysis of in-situ NaI γ-ray marine spectra. → Wavelet denoising technique provides smoothed spectra even at parts of the energy spectrum that exhibits strong statistical fluctuations. → Automated analysis provides peak detection, net area calculation, energy autocalibration, radionuclide identification and activity calculation. → Analysis of short-term spectra with poor statistical information is considerably improved.

  2. Automating with SIMATIC S7-1500 configuring, programming and testing with STEP 7 Professional

    CERN Document Server

    Berger, Hans

    2014-01-01

    With many innovations, the SIMATIC S7-1500 programmable logic controller (PLC) sets new standards in productivity and efficiency in control technology. By its outstanding system performance and with PROFINET as the standard interface, it ensures extremely short system response times and the highest control quality with a maximum of flexibility for most demanding automation tasks. The engineering software STEP 7 Professional operates inside TIA Portal, a user interface that is designed for intuitive operation. Functionality includes all aspects of Automation: from the configuration of the controllers via the programming in the IEC languages ¿¿LAD, FBD, STL, and SCL up to the program test. In the book, the hardware components of the automation system S7-1500 are presented including the description of their configuration and parameterization. A comprehensive introduction into STEP 7 Professional illustrates the basics of programming and troubleshooting. Beginners learn the basics of automation with Simatic...

  3. Reduction of short wavelength reflectance of multi-wall carbon nanotubes through ultraviolet laser irradiation

    Science.gov (United States)

    Stephens, Michelle S.; Simonds, Brian J.; Yung, Christopher S.; Conklin, Davis; Livigni, David J.; Oliva, Alberto Remesal; Lehman, John H.

    2018-05-01

    Multi-wall carbon nanotube coatings are used as broadband, low-reflectance absorbers for bolometric applications and for stray light control. They are also used as high emittance blackbody radiators. Irradiation of single wall carbon nanotubes with ultraviolet (UV) laser light has been shown to remove amorphous carbon debris, but there have been few investigations of the interaction of UV light with the more complex physics of multi-wall carbon nanotubes. We present measurements of reflectance and surface morphology before and after exposure of multi-wall carbon nanotube coatings to 248 nm UV laser light. We show that UV exposure reduces the reflectivity at wavelengths below 600 nm and present modeling of the thermal cycling the UV exposure causes at the surface of the carbon nanotubes. This effect can be used to flatten the spectral shape of the reflectivity curve of carbon nanotube absorber coatings used for broadband applications. Finally, we find that the effect of UV exposure depends on the nanotube growth process.

  4. Interprofessional education and social interaction: The use of automated external defibrillators in team-based basic life support.

    Science.gov (United States)

    Onan, Arif; Simsek, Nurettin

    2017-04-01

    Automated external defibrillators are pervasive computing devices designed for the treatment and management of acute sudden cardiac arrest. This study aims to explain users' actual use behavior in teams formed by different professions taken after a short time span of interaction with automated external defibrillator. Before the intervention, all the participants were certified with the American Heart Association Basic Life Support for healthcare providers. A statistically significant difference was revealed in mean individual automated external defibrillator technical skills between uniprofessional and interprofessional groups. The technical automated external defibrillator team scores were greater for groups with interprofessional than for those with uniprofessional education. The nontechnical automated external defibrillator skills of interprofessional and uniprofessional teams revealed differences in advantage of interprofessional teams. Students positively accept automated external defibrillators if well-defined and validated training opportunities to use them expertly are available. Uniprofessional teams were successfully supported by their members and, thereby, used automated external defibrillator effectively. Furthermore, the interprofessional approach resulted in as much effective teamwork as the uniprofessional approach.

  5. Subducted slabs and lateral viscosity variations: effects on the long-wavelength geoid

    Science.gov (United States)

    Tosi, Nicola; Čadek, Ondřej; Martinec, Zdeněk

    2009-11-01

    The characteristic broad local maxima exhibited by the long-wavelength geoid over subduction zones are investigated with a numerical model of mantle flow. In a spherical axisymmetric geometry, a synthetic model of buoyancy driven subduction is used to test the effects on the geoid caused by the depth of penetration of the lithosphere into the mantle, by the viscosity stratification and by lateral viscosity variations (LVV) in the lithosphere, upper and lower mantle. The presence of anomalous slab density in the lower mantle guarantees geoid amplitudes comparable with the observations, favouring the picture of slabs that penetrate the transition zone and sink into the deep mantle. The viscosity of the lower mantle controls the long-wavelength geoid to the first order, ensuring a clear positive signal when it is at least 30-times greater than the upper-mantle viscosity. The presence of LVV in the lithosphere, in the form of weak plate margins, helps to increase the contribution of the surface topography, causing a pronounced reduction of the geoid. Localized LVV associated with the cold slab play a secondary role if they are in the upper mantle. On the other hand, highly viscous slabs in the lower mantle exert a large influence on the geoid. They cause its amplitude to increase dramatically, way beyond the values typically observed over subduction zones. Long-wavelength flow becomes less vigorous as the slab viscosity increases. Deformation in the upper mantle becomes more localized and power is transferred to short wavelengths, causing the long-wavelength surface topography to diminish and the total geoid to increase. Slabs may be then weakened in the lower mantle or retain their high viscosity while other mechanisms act to lower the geoid. It is shown that a phase change from perovskite to post-perovskite above the core-mantle boundary can cause the geoid to reduce significantly, thereby helping to reconcile models and observations.

  6. Automated spectrophotometer for plutonium and uranium determination

    International Nuclear Information System (INIS)

    Jackson, D.D.; Hodgkins, D.J.; Hollen, R.M.; Rein, J.E.

    1975-09-01

    The automated spectrophotometer described is the first in a planned series of automated instruments for determining plutonium and uranium in nuclear fuel cycle materials. It has a throughput rate of 5 min per sample and uses a highly specific method of analysis for these elements. The range of plutonium and uranium measured is 0.5 to 14 mg and 1 to 14 mg, respectively, in 0.5 ml or less of solution with an option to pre-evaporate larger volumes. The precision of the measurements is about 0.02 mg standard deviation over the range corresponding to about 2 rel percent at the 1-mg level and 0.2 rel percent at the 10-mg level. The method of analysis involves the extraction of tetrapropylammonium plutonyl and uranyl trinitrate complexes into 2-nitropropane and the measurement of the optical absorbances in the organic phase at unique peak wavelengths. Various aspects of the chemistry associated with the method are presented. The automated spectrophotometer features a turntable that rotates as many as 24 samples in tubes to a series of stations for the sequential chemical operations of reagent addition and phase mixing to effect extraction, and then to a station for the absorbance measurement. With this system, the complications of sample transfers and flow-through cells are avoided. The absorbance measurement system features highly stable interference filters and a microcomputer that controls the timing sequence and operation of the system components. Output is a paper tape printout of three numbers: a four-digit number proportional to the quantity of plutonium or uranium, a two-digit number that designates the position of the tube in the turntable, and a one-digit number that designates whether plutonium or uranium was determined. Details of the mechanical and electrical components of the instrument and of the hardware and software aspects of the computerized control system are provided

  7. Home Automation

    OpenAIRE

    Ahmed, Zeeshan

    2010-01-01

    In this paper I briefly discuss the importance of home automation system. Going in to the details I briefly present a real time designed and implemented software and hardware oriented house automation research project, capable of automating house's electricity and providing a security system to detect the presence of unexpected behavior.

  8. Programming of the Wavelength Stabilization for a Titanium:Sapphire Laser using LabVIEW and Implementation into the CERN ISOLDE RILIS Measurement System

    CERN Document Server

    Rossel, Ralf Erik; Wendt, K; Rothe, S

    In the context of this work the foundation for the commissioning of a comprehensive environmental and operational data acquisition system was established. This development was performed for the Resonance Ionization Laser Ion Source (RILIS) at the ISOLDE radioactive ion beam facility within the European Organization for Nuclear Research CERN. As an essential step towards long-term automated operation, a remote control and wavelength stabilization system for the RILIS titanium:sapphire lasers was put into operation. This required the installation of a data recording infrastructure to work with a distributed sensor network. After operational data within the CERN technical computing network was collected and analyzed, the required wavelength adjustment was automatically performed by a stepper motor-driven correction system. The configuration of the hardware for acquisition and control and the integration of the dedicated system modules was performed using the graphical and data flow oriented programming language ...

  9. Sub-wavelength plasmon laser

    Science.gov (United States)

    Bora, Mihail; Bond, Tiziana C.

    2016-04-19

    A plasmonic laser device has resonant nanocavities filled with a gain medium containing an organic dye. The resonant plasmon frequencies of the nanocavities are tuned to align with both the absorption and emission spectra of the dye. Variables in the system include the nature of the dye and the wavelength of its absorption and emission, the wavelength of the pumping radiation, and the resonance frequencies of the nanocavities. In addition the pumping frequency of the dye is selected to be close to the absorption maximum.

  10. Analysis of subsystems in wavelength-division-multiplexing networks

    DEFF Research Database (Denmark)

    Liu, Fenghai

    2001-01-01

    Wavelength division multiplexing (WDM) technology together with optical amplification has created a new era for optical communication. Transmission capacity is greatly increased by adding more and more wavelength channels into a single fiber, as well as by increasing the line rate of each channel...... in semiconductor optical amplifiers (SOAs), and dispersion managed fiber sections. New subsystems are also proposed in the thesis: a modular 2×2 multiwavelength cross-connect using wavelength switching blocks, a wavelength converter based on cross phase modulation in a semiconductor modulator, a wavelength...

  11. Optimization of automation: I. Estimation method of cognitive automation rates reflecting the effects of automation on human operators in nuclear power plants

    International Nuclear Information System (INIS)

    Lee, Seung Min; Kim, Jong Hyun; Seong, Poong Hyun

    2014-01-01

    Highlights: • We propose an estimation method of the automation rate by taking the advantages of automation as the estimation measures. • We conduct the experiments to examine the validity of the suggested method. • The higher the cognitive automation rate is, the greater the decreased rate of the working time will be. • The usefulness of the suggested estimation method is proved by statistical analyses. - Abstract: Since automation was introduced in various industrial fields, the concept of the automation rate has been used to indicate the inclusion proportion of automation among all work processes or facilities. Expressions of the inclusion proportion of automation are predictable, as is the ability to express the degree of the enhancement of human performance. However, many researchers have found that a high automation rate does not guarantee high performance. Therefore, to reflect the effects of automation on human performance, this paper proposes a new estimation method of the automation rate that considers the effects of automation on human operators in nuclear power plants (NPPs). Automation in NPPs can be divided into two types: system automation and cognitive automation. Some general descriptions and characteristics of each type of automation are provided, and the advantages of automation are investigated. The advantages of each type of automation are used as measures of the estimation method of the automation rate. One advantage was found to be a reduction in the number of tasks, and another was a reduction in human cognitive task loads. The system and the cognitive automation rate were proposed as quantitative measures by taking advantage of the aforementioned benefits. To quantify the required human cognitive task loads and thus suggest the cognitive automation rate, Conant’s information-theory-based model was applied. The validity of the suggested method, especially as regards the cognitive automation rate, was proven by conducting

  12. The At-Wavelength Metrology Facility at BESSY-II

    Directory of Open Access Journals (Sweden)

    Franz Schäfers

    2016-02-01

    Full Text Available The At-Wavelength Metrology Facility at BESSY-II is dedicated to short-term characterization of novel UV, EUV and XUV optical elements, such as diffraction gratings, mirrors, multilayers and nano-optical devices like reflection zone plates. It consists of an Optics Beamline PM-1 and a Reflectometer in a clean-room hutch as a fixed end station. The bending magnet Beamline is a Plane Grating Monochromator beamline (c-PGM equipped with an SX700 monochromator. The beamline is specially tailored for efficient high-order suppression and stray light reduction. The versatile 11-axes UHV-Reflectometer can house life-sized optical elements, which are fully adjustable and of which the reflection properties can be measured in the full incidence angular range as well as in the full azimuthal angular range to determine polarization properties.

  13. An automated blood sampling system used in positron emission tomography

    International Nuclear Information System (INIS)

    Eriksson, L.; Bohm, C.; Kesselberg, M.

    1988-01-01

    Fast dynamic function studies with positron emission tomography (PET), has the potential to give accurate information of physiological functions of the brain. This capability can be realised if the positron camera system accurately quantitates the tracer uptake in the brain with sufficiently high efficiency and in sufficiently short time intervals. However, in addition, the tracer concentration in blood, as a function of time, must be accurately determined. This paper describes and evaluates an automated blood sampling system. Two different detector units are compared. The use of the automated blood sampling system is demonstrated in studies of cerebral blood flow, in studies of the blood-brain barrier transfer of amino acids and of the cerebral oxygen consumption. 5 refs.; 7 figs

  14. Automatic location of short circuit faults

    Energy Technology Data Exchange (ETDEWEB)

    Lehtonen, M. [VTT Energy, Espoo (Finland); Hakola, T.; Antila, E. [ABB Power Oy, Helsinki (Finland); Seppaenen, M. [North-Carelian Power Company (Finland)

    1996-12-31

    In this presentation, the automatic location of short circuit faults on medium voltage distribution lines, based on the integration of computer systems of medium voltage distribution network automation is discussed. First the distribution data management systems and their interface with the substation telecontrol, or SCADA systems, is studied. Then the integration of substation telecontrol system and computerised relay protection is discussed. Finally, the implementation of the fault location system is presented and the practical experience with the system is discussed

  15. Automatic location of short circuit faults

    Energy Technology Data Exchange (ETDEWEB)

    Lehtonen, M [VTT Energy, Espoo (Finland); Hakola, T; Antila, E [ABB Power Oy (Finland); Seppaenen, M [North-Carelian Power Company (Finland)

    1998-08-01

    In this chapter, the automatic location of short circuit faults on medium voltage distribution lines, based on the integration of computer systems of medium voltage distribution network automation is discussed. First the distribution data management systems and their interface with the substation telecontrol, or SCADA systems, is studied. Then the integration of substation telecontrol system and computerized relay protection is discussed. Finally, the implementation of the fault location system is presented and the practical experience with the system is discussed

  16. Automatic location of short circuit faults

    Energy Technology Data Exchange (ETDEWEB)

    Lehtonen, M [VTT Energy, Espoo (Finland); Hakola, T; Antila, E [ABB Power Oy, Helsinki (Finland); Seppaenen, M [North-Carelian Power Company (Finland)

    1997-12-31

    In this presentation, the automatic location of short circuit faults on medium voltage distribution lines, based on the integration of computer systems of medium voltage distribution network automation is discussed. First the distribution data management systems and their interface with the substation telecontrol, or SCADA systems, is studied. Then the integration of substation telecontrol system and computerised relay protection is discussed. Finally, the implementation of the fault location system is presented and the practical experience with the system is discussed

  17. Automated astatination of biomolecules - a stepping stone towards multicenter clinical trials

    DEFF Research Database (Denmark)

    Aneheim, Emma; Albertsson, Per; Bäck, Tom

    2015-01-01

    To facilitate multicentre clinical studies on targeted alpha therapy, it is necessary to develop an automated, on-site procedure for conjugating rare, short-lived, alpha-emitting radionuclides to biomolecules. Astatine-211 is one of the few alpha-emitting nuclides with appropriate chemical...... vector, which can guide the radiation to the cancer cells. Consequently, an appropriate method is required for coupling the nuclide to the vector. To increase the availability of astatine-211 radiopharmaceuticals for targeted alpha therapy, their production should be automated. Here, we present a method...... challenging, alpha-emitting radionuclide. In this work, we describe the process platform, and we demonstrate the production of both astaine-211, for preclinical use, and astatine-211 labelled antibodies....

  18. Automation facilities for agricultural machinery control

    Directory of Open Access Journals (Sweden)

    A. Yu. Izmaylov

    2017-01-01

    Full Text Available The possibility of use of the automation equipment for agricultural machinery control is investigated. The authors proposed solutions on creation of the centralized unified automated information system for mobile aggregates management. In accordance with the modern requirements this system should be open, integrated into the general schema of agricultural enterprise control. Standard hardware, software and communicative features should be realized in tasks of monitoring and control. Therefore the schema should be get with use the unified modules and Russian standards. The complex multivariate unified automated control system for different objects of agricultural purpose based on block and modular creation should correspond to the following principles: high reliability, simplicity of service, low expenses in case of operation, the short payback period connected to increase in productivity, the reduced losses when harvesting, postharvest processing and storage, the improved energetic indices. Technological processes control in agricultural production is exercised generally with feedback. The example without feedback is program control by temperature in storage in case of the cooling mode. Feedback at technological processes control in agricultural production allows to optimally solve a problem of rational distribution of functions in man-distributed systems and forming the intelligent ergonomic interfaces, consistent with professional perceptions of decision-makers. The negative feedback created by the control unit allows to support automatically a quality index of technological process at the set level. The quantitative analysis of a production situation base itself upon deeply formalized basis of computer facilities that promotes making of the optimal solution. Information automated control system introduction increases labor productivity by 40 percent, reduces energetic costs by 25 percent. Improvement of quality of the executed technological

  19. Josephson frequency meter for millimeter and submillimeter wavelengths

    Energy Technology Data Exchange (ETDEWEB)

    Anischenko, S.E.; Larkin, S.Y.; Chaikovsky, V.I. [State Research Center, Kiev (Ukraine)] [and others

    1994-12-31

    Frequency measurements of electromagnetic oscillations of millimeter and submillimeter wavebands with frequency growth due to a number of reasons become more and more difficult. First, these frequencies are considered to be cutoff for semiconductor converting devices and one has to use optical measurement methods instead of traditional ones with frequency transfer. Second, resonance measurement methods are characterized by using relatively narrow bands and optical ones are limited in frequency and time resolution due to the limited range and velocity of movement of their mechanical elements as well as the efficiency of these optical techniques decreases with the increase of wavelength due to diffraction losses. That requires the apriori information on the radiation frequency band of the source involved. Method of measuring frequency of harmonic microwave signals in millimeter and submillimeter wavebands based on the ac Josephson effect in superconducting contacts is devoid of all the above drawbacks. This approach offers a number of major advantages over the more traditional measurement methods, that is the one based on frequency conversion, resonance and interferrometric techniques. It can be characterized by high potential accuracy, wide range of frequencies measured, prompt measurement and the opportunity to obtain panoramic display of the results as well as full automation of the measuring process.

  20. Josephson frequency meter for millimeter and submillimeter wavelengths

    International Nuclear Information System (INIS)

    Anischenko, S.E.; Larkin, S.Y.; Chaikovsky, V.I.

    1994-01-01

    Frequency measurements of electromagnetic oscillations of millimeter and submillimeter wavebands with frequency growth due to a number of reasons become more and more difficult. First, these frequencies are considered to be cutoff for semiconductor converting devices and one has to use optical measurement methods instead of traditional ones with frequency transfer. Second, resonance measurement methods are characterized by using relatively narrow bands and optical ones are limited in frequency and time resolution due to the limited range and velocity of movement of their mechanical elements as well as the efficiency of these optical techniques decreases with the increase of wavelength due to diffraction losses. That requires the apriori information on the radiation frequency band of the source involved. Method of measuring frequency of harmonic microwave signals in millimeter and submillimeter wavebands based on the ac Josephson effect in superconducting contacts is devoid of all the above drawbacks. This approach offers a number of major advantages over the more traditional measurement methods, that is the one based on frequency conversion, resonance and interferrometric techniques. It can be characterized by high potential accuracy, wide range of frequencies measured, prompt measurement and the opportunity to obtain panoramic display of the results as well as full automation of the measuring process

  1. First tests of a multi-wavelength mini-DIAL system for the automatic detection of greenhouse gases

    Science.gov (United States)

    Parracino, S.; Gelfusa, M.; Lungaroni, M.; Murari, A.; Peluso, E.; Ciparisse, J. F.; Malizia, A.; Rossi, R.; Ventura, P.; Gaudio, P.

    2017-10-01

    Considering the increase of atmospheric pollution levels in our cities, due to emissions from vehicles and domestic heating, and the growing threat of terrorism, it is necessary to develop instrumentation and gather know-how for the automatic detection and measurement of dangerous substances as quickly and far away as possible. The Multi- Wavelength DIAL, an extension of the conventional DIAL technique, is one of the most powerful remote sensing methods for the identification of multiple substances and seems to be a promising solution compared to existing alternatives. In this paper, first in-field tests of a smart and fully automated Multi-Wavelength mini-DIAL will be presented and discussed in details. The recently developed system, based on a long-wavelength infrared (IR-C) CO2 laser source, has the potential of giving an early warning, whenever something strange is found in the atmosphere, followed by identification and simultaneous concentration measurements of many chemical species, ranging from the most important Greenhouse Gases (GHG) to other harmful Volatile Organic Compounds (VOCs). Preliminary studies, regarding the fingerprint of the investigated substances, have been carried out by cross-referencing database of infrared (IR) spectra, obtained using in-cell measurements, and typical Mixing Ratios in the examined region, extrapolated from the literature. First experiments in atmosphere have been performed into a suburban and moderately-busy area of Rome. Moreover, to optimize the automatic identification of the harmful species to be recognized on the basis of in cell measurements of the absorption coefficient spectra, an advanced multivariate statistical method for classification has been developed and tested.

  2. Process automation

    International Nuclear Information System (INIS)

    Moser, D.R.

    1986-01-01

    Process automation technology has been pursued in the chemical processing industries and to a very limited extent in nuclear fuel reprocessing. Its effective use has been restricted in the past by the lack of diverse and reliable process instrumentation and the unavailability of sophisticated software designed for process control. The Integrated Equipment Test (IET) facility was developed by the Consolidated Fuel Reprocessing Program (CFRP) in part to demonstrate new concepts for control of advanced nuclear fuel reprocessing plants. A demonstration of fuel reprocessing equipment automation using advanced instrumentation and a modern, microprocessor-based control system is nearing completion in the facility. This facility provides for the synergistic testing of all chemical process features of a prototypical fuel reprocessing plant that can be attained with unirradiated uranium-bearing feed materials. The unique equipment and mission of the IET facility make it an ideal test bed for automation studies. This effort will provide for the demonstration of the plant automation concept and for the development of techniques for similar applications in a full-scale plant. A set of preliminary recommendations for implementing process automation has been compiled. Some of these concepts are not generally recognized or accepted. The automation work now under way in the IET facility should be useful to others in helping avoid costly mistakes because of the underutilization or misapplication of process automation. 6 figs

  3. From laboratory to the sky: Th-Ar wavelength standards for the cryogenic infrared echelle spectrograph (CRIRES)

    Energy Technology Data Exchange (ETDEWEB)

    Kerber, Florian; Bristow, Paul [European Southern Observatory, Karl-Schwarzschild-Strasse 2, 85748 Garching (Germany); Nave, Gillian; Sansonetti, Craig J [National Institute of Standards and Technology, Gaithersburg, MD (United States)], E-mail: fkerber@eso.org, E-mail: gillian.nave@nist.gov, E-mail: craig.sansonetti@nist.gov, E-mail: bristowp@eso.org

    2009-05-15

    We report on the collaborative effort of the European Southern Observatory (ESO) and the National Institute of Standards and Technology (NIST) to establish-through laboratory measurements-wavelength standards in the near-infrared (IR) emission line spectrum of a low current Th-Ar hollow cathode lamp. These standards are now routinely used for the wavelength calibration of the cryogenic infrared echelle spectrograph (CRIRES) operated at one of the unit telescopes of the very large telescope (VLT) at ESO's La Silla Paranal Observatory in Chile. The availability of highly accurate wavelength standards from a commercially available calibration source permits a shift to a new operational paradigm for high-resolution IR spectroscopy. Wavelength calibration no longer has to rely on atmospheric features but can make use of laboratory traceable reference data as is normally done in the ultraviolet and visible regions. This opens the door for more quantitative spectroscopic work in the near-IR. To illustrate the potential impact of this development, we briefly review the current state of affairs in IR astronomy and its projected future. With the advent of the next generation of extremely large ground-based telescopes the IR region will become the most powerful window on the universe within the next 10-15 years. We conclude with a short outlook on the contribution atomic physics can make to this evolution.

  4. Wavelength mismatch effect in electromagnetically induced absorption

    International Nuclear Information System (INIS)

    Bharti, Vineet; Wasan, Ajay; Natarajan, Vasant

    2016-01-01

    We present a theoretical investigation of the phenomenon of electromagnetically induced absorption (EIA) in a 4-level system consisting of vee and ladder subsystems. The four levels are coupled using one weak probe field, and two strong control fields. We consider an experimental realization using energy levels of Rb. This necessitates dealing with different conditions of wavelength mismatch—near-perfect match where all three wavelengths are approximately equal; partial mismatch where the wavelength of one control field is less than the other fields; and complete mismatch where all three wavelengths are unequal. We present probe absorption profiles with Doppler averaging at room temperature to account for experiments in a room temperature Rb vapor cell. Our analysis shows that EIA resonances can be studied using Rydberg states excited with diode lasers. - Highlights: • Wavelength mismatch effect is investigated in electromagnetically induced absorption (EIA). • An experimental realization of 4-level vee + ladder system using energy levels of rubidium atom is presented. • EIA resonances are studied under different conditions of wavelength mismatch. • Possibility of observation of EIA using Rydberg states excited with diode lasers.

  5. Wavelength mismatch effect in electromagnetically induced absorption

    Energy Technology Data Exchange (ETDEWEB)

    Bharti, Vineet [Department of Physics, Indian Institute of Science, Bangalore 560012 (India); Wasan, Ajay [Department of Physics, Indian Institute of Technology, Roorkee 247667 (India); Natarajan, Vasant [Department of Physics, Indian Institute of Science, Bangalore 560012 (India)

    2016-07-15

    We present a theoretical investigation of the phenomenon of electromagnetically induced absorption (EIA) in a 4-level system consisting of vee and ladder subsystems. The four levels are coupled using one weak probe field, and two strong control fields. We consider an experimental realization using energy levels of Rb. This necessitates dealing with different conditions of wavelength mismatch—near-perfect match where all three wavelengths are approximately equal; partial mismatch where the wavelength of one control field is less than the other fields; and complete mismatch where all three wavelengths are unequal. We present probe absorption profiles with Doppler averaging at room temperature to account for experiments in a room temperature Rb vapor cell. Our analysis shows that EIA resonances can be studied using Rydberg states excited with diode lasers. - Highlights: • Wavelength mismatch effect is investigated in electromagnetically induced absorption (EIA). • An experimental realization of 4-level vee + ladder system using energy levels of rubidium atom is presented. • EIA resonances are studied under different conditions of wavelength mismatch. • Possibility of observation of EIA using Rydberg states excited with diode lasers.

  6. Surface photo-discoloration and degradation of dyed wood veneer exposed to different wavelengths of artificial light

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yi [MOE Key Laboratory of Wooden Material Science and Application, Beijing Forestry University, Beijing 100083 (China); Beijing Key Laboratory of Wood Science and Engineering, Beijing Forestry University, Beijing 100083 (China); MOE Engineering Research Center of Forestry Biomass Materials and Bioenergy, Beijing Forestry University, Beijing 100083 (China); Forest Products Development Center, School of Forestry and Wildlife Sciences, Auburn University, Auburn, AL 36830 (United States); Shao, Lingmin [MOE Key Laboratory of Wooden Material Science and Application, Beijing Forestry University, Beijing 100083 (China); Gao, Jianmin, E-mail: jmgao@bjfu.edu.cn [MOE Key Laboratory of Wooden Material Science and Application, Beijing Forestry University, Beijing 100083 (China); Beijing Key Laboratory of Wood Science and Engineering, Beijing Forestry University, Beijing 100083 (China); MOE Engineering Research Center of Forestry Biomass Materials and Bioenergy, Beijing Forestry University, Beijing 100083 (China); Guo, Hongwu, E-mail: hwg5052@163.com [MOE Key Laboratory of Wooden Material Science and Application, Beijing Forestry University, Beijing 100083 (China); Beijing Key Laboratory of Wood Science and Engineering, Beijing Forestry University, Beijing 100083 (China); MOE Engineering Research Center of Forestry Biomass Materials and Bioenergy, Beijing Forestry University, Beijing 100083 (China); Chen, Yao [MOE Key Laboratory of Wooden Material Science and Application, Beijing Forestry University, Beijing 100083 (China); Beijing Key Laboratory of Wood Science and Engineering, Beijing Forestry University, Beijing 100083 (China); MOE Engineering Research Center of Forestry Biomass Materials and Bioenergy, Beijing Forestry University, Beijing 100083 (China); Cheng, Qingzheng; Via, Brian K. [Forest Products Development Center, School of Forestry and Wildlife Sciences, Auburn University, Auburn, AL 36830 (United States)

    2015-03-15

    Highlights: • Investigate the selective absorption of different wavelengths of UV–vis light by dyed wood chromophores. • Identify connection between light wavelengths and surface color changes and chemical structure degradation. • Study hypochromic effect based on surface reflectance and K/S absorption changes during UV–vis irradiation. - Abstract: The surface of dyed wood is prone to discoloration when exposed to light irradiation which significantly decreases its decorative effect and shortens its service life. The influence of light wavelength exposure to the surface of dyed wood was investigated to study the effect on discoloration and degradation. Acid Blue V and Acid Red GR dyed wood veneers were subjected to light exposure with different wavelengths from the UV to visible region (254–420 nm). Results showed that the surface discoloration of dyed wood was linearly related to lignin concentration and dyes degradation and the consequent transformation of chromophoric groups such as aromatic (C=C) and carbonyl (C=O) through methoxy reaction. The dyes, lignin and some active constituents were degraded severely, even at short exposures. Acid Blue V dyed wood exhibited greater discoloration than the Acid Red GR treatment. The reflectance and K/S absorption curve showed a hypochromic effect on the dyed wood surface. The dyes and wood chemical structure played a complex and combined role on the selective absorption of different wavelengths of light. The color change rate was apparent with 254 nm exposure in the initial stages, but a greater discoloration rate occurred on the samples irradiated at 313 and 340 nm than at 254 and 420 nm with the time prolonged. The degradation rate and degree of discoloration correlated well with the light energy and wavelength.

  7. Observations of the polarized emission of Taurus A, Cas A and Cygnus A at 9-mm wavelength

    International Nuclear Information System (INIS)

    Flett, A.M.; Henderson, C.

    1979-01-01

    Measurements of the total intensity and degree of linear polarization of the supernova remnants Taurus A and Cas A and of the radiogalaxy Cygnus A have been made at lambda 9 mm using the 25-m radiotelescope at Chilbolton. A new experimental technique involving Faraday rotation of the incoming polarized radiation was employed. Taurus A shows the expected strong and uniform polarization over the central area investigated, and Cas A the ring-like distribution observed at other wavelengths. The beamwidth of 1.5 arcmin resolves the two major components of Cygnus A and it is found that the polarization in the E component has a position angle of 53 +- 3 0 and P = 7.5 +- 1.2 per cent, and the W component a position angle of 133 +- 3 0 and P = 9.6 +-1.1 per cent. When these results are combined with earlier data at longer wavelengths, the large rotation measure of the E component and the fall of the degree of polarization of the W component at short wavelength are further established. (author)

  8. Optimum electron temperature and density for short-wavelength plasma-lasing from nickel-like ions

    International Nuclear Information System (INIS)

    Masoudnia, Leili; Bleiner, Davide

    2014-01-01

    Soft X-ray lasing across a Ni-like plasma gain-medium requires optimum electron temperature and density for attaining to the Ni-like ion stage and for population inversion in the 3d 9 4d 1 (J=0)→3d 9 4p 1 (J=1) laser transition. Various scaling laws, function of operating parameters, were compared with respect to their predictions for optimum temperatures and densities. It is shown that the widely adopted local thermodynamic equilibrium (LTE) model underestimates the optimum plasma-lasing conditions. On the other hand, non-LTE models, especially when complemented with dielectronic recombination, provided accurate prediction of the optimum plasma-lasing conditions. It is further shown that, for targets with Z equal or greater than the rare-earth elements (e.g. Sm), the optimum electron density for plasma-lasing is not accessible for pump-pulses at λ=1ω=1μm. This observation explains a fundamental difficulty in saturating the wavelength of plasma-based X-ray lasers below 6.8 nm, unless using 2ω pumping

  9. Driving Performance After Self-Regulated Control Transitions in Highly Automated Vehicles.

    Science.gov (United States)

    Eriksson, Alexander; Stanton, Neville A

    2017-12-01

    This study aims to explore whether driver-paced, noncritical transitions of control may counteract some of the aftereffects observed in the contemporary literature, resulting in higher levels of vehicle control. Research into control transitions in highly automated driving has focused on urgent scenarios where drivers are given a relatively short time span to respond to a request to resume manual control, resulting in seemingly scrambled control when manual control is resumed. Twenty-six drivers drove two scenarios with an automated driving feature activated. Drivers were asked to read a newspaper or monitor the system and relinquish or resume control from the automation when prompted by vehicle systems. Driving performance in terms of lane positioning and steering behavior was assessed for 20 seconds post resuming control to capture the resulting level of control. It was found that lane positioning was virtually unaffected for the duration of the 20-second time span in both automated conditions compared to the manual baseline when drivers resumed manual control; however, significant increases in the standard deviation of steering input were found for both automated conditions compared to baseline. No significant differences were found between the two automated conditions. The results indicate that when drivers self-paced the transfer back to manual control they exhibit less of the detrimental effects observed in system-paced conditions. It was shown that self-paced transitions could reduce the risk of accidents near the edge of the operational design domain. Vehicle manufacturers must consider these benefits when designing contemporary systems.

  10. Free-space wavelength-multiplexed optical scanner.

    Science.gov (United States)

    Yaqoob, Z; Rizvi, A A; Riza, N A

    2001-12-10

    A wavelength-multiplexed optical scanning scheme is proposed for deflecting a free-space optical beam by selection of the wavelength of the light incident on a wavelength-dispersive optical element. With fast tunable lasers or optical filters, this scanner features microsecond domain scan setting speeds and large- diameter apertures of several centimeters or more for subdegree angular scans. Analysis performed indicates an optimum scan range for a given diffraction order and grating period. Limitations include beam-spreading effects based on the varying scanner aperture sizes and the instantaneous information bandwidth of the data-carrying laser beam.

  11. Dynamic Sensor Interrogation Using Wavelength-Swept Laser with a Polygon-Scanner-Based Wavelength Filter

    Science.gov (United States)

    Kwon, Yong Seok; Ko, Myeong Ock; Jung, Mi Sun; Park, Ik Gon; Kim, Namje; Han, Sang-Pil; Ryu, Han-Cheol; Park, Kyung Hyun; Jeon, Min Yong

    2013-01-01

    We report a high-speed (∼2 kHz) dynamic multiplexed fiber Bragg grating (FBG) sensor interrogation using a wavelength-swept laser (WSL) with a polygon-scanner-based wavelength filter. The scanning frequency of the WSL is 18 kHz, and the 10 dB scanning bandwidth is more than 90 nm around a center wavelength of 1,540 nm. The output from the WSL is coupled into the multiplexed FBG array, which consists of five FBGs. The reflected Bragg wavelengths of the FBGs are 1,532.02 nm, 1,537.84 nm, 1,543.48 nm, 1,547.98 nm, and 1,553.06 nm, respectively. A dynamic periodic strain ranging from 500 Hz to 2 kHz is applied to one of the multiplexed FBGs, which is fixed on the stage of the piezoelectric transducer stack. Good dynamic performance of the FBGs and recording of their fast Fourier transform spectra have been successfully achieved with a measuring speed of 18 kHz. The signal-to-noise ratio and the bandwidth over the whole frequency span are determined to be more than 30 dB and around 10 Hz, respectively. We successfully obtained a real-time measurement of the abrupt change of the periodic strain. The dynamic FBG sensor interrogation system can be read out with a WSL for high-speed and high-sensitivity real-time measurement. PMID:23899934

  12. Optical coherence tomography evaluation of retinal nerve fiber layer in longitudinally extensive transverse myelitis

    Directory of Open Access Journals (Sweden)

    Frederico C. Moura

    2011-02-01

    Full Text Available OBJECTIVE: To compare optical coherence tomography (OCT measurements on the retinal nerve fiber layer (RNFL of healthy controls and patients with longitudinally extensive transverse myelitis (LETM without previous optic neuritis. METHOD: Twenty-six eyes from 26 patients with LETM and 26 control eyes were subjected to automated perimetry and OCT for comparison of RNFL measurements. RESULTS: The mean deviation values from perimetry were significantly lower in patients with LETM than in controls (p<0.0001. RNFL measurements in the nasal quadrant and in the 3-o'clock segment were significantly smaller in LETM eyes than in controls. (p=0.04 and p=0.006, respectively. No significantly differences in other RNFL measurements were found. CONCLUSION: Patients with LETM may present localized RNFL loss, particularly on the nasal side of the optic disc, associated with slight visual field defects, even in the absence of previous episodes of optic neuritis. These findings emphasize the fact that patients with LETM may experience attacks of subclinical optic nerve damage.

  13. The influence of iris color on the pupillary light reflex.

    Science.gov (United States)

    Bergamin, O; Schoetzau, A; Sugimoto, K; Zulauf, M

    1998-08-01

    This study was carried out to investigate the effect of iris color on the pupillary light reflex (PLR) in normal healthy volunteers. Pupil perimetry was performed on 50 healthy volunteers with the Octopus 1-2-3 automated perimeter. Within the 30-deg visual field, 33 test locations were investigated four times. Stimulus parameters were Goldmann size V (1.72 degrees), intensity 1632 cd/m2, stimulus time 200 ms, background illumination 0 cd/m2, and interstimulus interval 3 s. Pupillometric parameters studied were initial pupil size, amplitude (magnitude of pupillary contraction), latency time, contraction time, pre-PLR movement, contraction velocity, and redilation velocity. Pupillometric parameters were investigated by analysis of variance by the independent variables blue and brown irides. Iris color (blue vs brown) influenced statistically significantly (P movement (0.328 mm2/s vs 0.325 mm2/s). Pupillary contraction amplitude and velocity depended on iris color, whereas pupil size and latency time were independent of iris color. Therefore, iris color might be considered when, evaluating pupillary movements in pupil perimetry.

  14. Short recovery time NMR probe

    International Nuclear Information System (INIS)

    Ramia, M.E.; Martin, C.A.; Jeandrevin, S.

    2011-01-01

    A NMR probe for low frequency and short recovery time is presented in this work. The probe contains the tuning circuit, diode expanders and quarter wavelength networks to protect the receiver from both the amplifier noise and the coil ringing following the transmitter power pulse. It also possesses a coil damper which is activated by of non active components. The probe performance shows a recovery time of about of 15μs a sensitive Q factor reduction and an increase of the signal to noise ratio of about 68% during the reception at a work frequency of 2 MHz. (author)

  15. Atomic layer deposition of absorbing thin films on nanostructured electrodes for short-wavelength infrared photosensing

    International Nuclear Information System (INIS)

    Xu, Jixian; Sutherland, Brandon R.; Hoogland, Sjoerd; Fan, Fengjia; Sargent, Edward H.; Kinge, Sachin

    2015-01-01

    Atomic layer deposition (ALD), prized for its high-quality thin-film formation in the absence of high temperature or high vacuum, has become an industry standard for the large-area deposition of a wide array of oxide materials. Recently, it has shown promise in the formation of nanocrystalline sulfide films. Here, we demonstrate the viability of ALD lead sulfide for photodetection. Leveraging the conformal capabilities of ALD, we enhance the absorption without compromising the extraction efficiency in the absorbing layer by utilizing a ZnO nanowire electrode. The nanowires are first coated with a thin shunt-preventing TiO 2 layer, followed by an infrared-active ALD PbS layer for photosensing. The ALD PbS photodetector exhibits a peak responsivity of 10 −2  A W −1 and a shot-derived specific detectivity of 3 × 10 9  Jones at 1530 nm wavelength

  16. Wavelength selection in traveling-wave convection in a fluid mixture

    International Nuclear Information System (INIS)

    Surko, C.M.; Eaton, K.D.; Baxter, G.W.; Iwata, K.

    1993-01-01

    The mechanisms by which a one-dimensional pattern of traveling waves changes wavelength (i.e. the Eckhaus instability) is studied in a binary fluid mixture. Propagating wavelength modulations develop when the Rayleigh number of the system is decreased below a wavelength-dependent threshold, commonly referred to as the Eckhaus boundary. These wavelength modulations increase in amplitude and narrow in spatial extent until they trigger the creation or annihilation of convection roll pairs and thereby change the average wavelength of the system. The authors find qualitatively different dynamics for wavelength-increasing events and wavelength-decreasing events; these differences are due to the strong wavelength dependence of the group velocity

  17. Load Segmentation for Convergence of Distribution Automation and Advanced Metering Infrastructure Systems

    Science.gov (United States)

    Pamulaparthy, Balakrishna; KS, Swarup; Kommu, Rajagopal

    2014-12-01

    Distribution automation (DA) applications are limited to feeder level today and have zero visibility outside of the substation feeder and reaching down to the low-voltage distribution network level. This has become a major obstacle in realizing many automated functions and enhancing existing DA capabilities. Advanced metering infrastructure (AMI) systems are being widely deployed by utilities across the world creating system-wide communications access to every monitoring and service point, which collects data from smart meters and sensors in short time intervals, in response to utility needs. DA and AMI systems convergence provides unique opportunities and capabilities for distribution grid modernization with the DA system acting as a controller and AMI system acting as feedback to DA system, for which DA applications have to understand and use the AMI data selectively and effectively. In this paper, we propose a load segmentation method that helps the DA system to accurately understand and use the AMI data for various automation applications with a suitable case study on power restoration.

  18. Construction of a flash-photolysis apparatus having a short discharge time

    International Nuclear Information System (INIS)

    Devillers, C.

    1964-01-01

    Flash photolysis aims at reaching directly the primary mechanisms resulting from the action of light on an absorbent matter. This makes it necessary to produce a flash as short and as bright as possible. Our main effort was directed towards reducing the duration of the flash by decreasing the self-inductance of the discharge circuit. A description of this circuit and study of the characteristics of the apparatus are followed by a short description of the two analytical methods: flash spectrography and absorption spectrophotometry at a given wave-length. (author) [fr

  19. Glaucoma management in patients with osteo-odonto-keratoprosthesis (OOKP): the Singapore OOKP Study.

    Science.gov (United States)

    Kumar, Rajesh S; Tan, Donald T H; Por, Yong-Ming; Oen, Francis T; Hoh, Sek-Tien; Parthasarathy, Anand; Aung, Tin

    2009-01-01

    To report diagnostic modalities and treatment options for glaucoma in eyes with osteo-odonto keratoprosthesis (OOKP). Eyes that underwent OOKP were evaluated for glaucoma at the time of the first postoperative visit, then at 1 and 3 months after the procedure, and thereafter every 6 months. All eyes underwent stereo-biomicroscopic optic nerve head (ONH) assessment, kinetic (Goldmann perimetry) and automated static visual field testing, ONH photography, Heidelberg retina tomograph, scanning laser polarimetery (GDx), and optical coherence tomography. Treatment of glaucoma was also reviewed. Average follow-up period was 19.1 (range: 5 to 31) months. Of the 15 eyes that underwent OOKP, 5 eyes had preexisting glaucoma. None of the other 10 eyes developed glaucoma after OOKP. ONH photography and visual field testing were the most reliable methods to assess status of the disease, whereas Heidelberg retina tomograph and optical coherence tomography could be performed with reasonable reproducibility and quality; GDx imaging was poor. All patients with glaucoma were treated with oral acetazolamide 500 mg twice a day. Transscleral cyclophotocoagulation was performed in 3 eyes at stage 2 of OOKP surgery. Progression of glaucoma was noted in 2 eyes on the basis of optic disc photographs and automated perimetry. Visual field testing and optic disc assessment with optic disc photographs seem to be effective methods to monitor eyes with OOKP for glaucoma. Treatment strategies include oral medications to lower intraocular pressure and cyclophotocoagulation.

  20. Wavelength scaling of laser plasma coupling

    International Nuclear Information System (INIS)

    Kruer, W.L.

    1983-01-01

    The use of shorter wavelength laser light both enhances collisional absorption and reduces deleterious collective plasma effects. Coupling processes which can be important in reactor-size targets are briefly reviewed. Simple estimates are presented for the intensity-wavelength regime in which collisional absorption is high and collective effects are minimized

  1. Short-term Automated Quantification of Radiologic Changes in the Characterization of Idiopathic Pulmonary Fibrosis Versus Nonspecific Interstitial Pneumonia and Prediction of Long-term Survival.

    Science.gov (United States)

    De Giacomi, Federica; Raghunath, Sushravya; Karwoski, Ronald; Bartholmai, Brian J; Moua, Teng

    2018-03-01

    Fibrotic interstitial lung diseases presenting with nonspecific and overlapping radiologic findings may be difficult to diagnose without surgical biopsy. We hypothesized that baseline quantifiable radiologic features and their short-term interval change may be predictive of underlying histologic diagnosis as well as long-term survival in idiopathic pulmonary fibrosis (IPF) presenting without honeycombing versus nonspecific interstitial pneumonia (NSIP). Forty biopsy-confirmed IPF and 20 biopsy-confirmed NSIP patients with available high-resolution chest computed tomography 4 to 24 months apart were studied. CALIPER software was used for the automated characterization and quantification of radiologic findings. IPF subjects were older (66 vs. 48; P<0.0001) with lower diffusion capacity for carbon monoxide and higher volumes of baseline reticulation (193 vs. 83 mL; P<0.0001). Over the interval period, compared with NSIP, IPF patients experienced greater functional decline (forced vital capacity, -6.3% vs. -1.7%; P=0.02) and radiologic progression, as noted by greater increase in reticulation volume (24 vs. 1.74 mL; P=0.048), and decrease in normal (-220 vs. -37.7 mL; P=0.045) and total lung volumes (-198 vs. 58.1 mL; P=0.03). Older age, male gender, higher reticulation volumes at baseline, and greater interval decrease in normal lung volumes were predictive of IPF. Both baseline and short-term changes in quantitative radiologic findings were predictive of mortality. Baseline quantitative radiologic findings and assessment of short-term disease progression may help characterize underlying IPF versus NSIP in those with difficult to differentiate clinicoradiologic presentations. Our study supports the possible utility of assessing serial quantifiable high-resolution chest computed tomographic findings for disease differentiation in these 2 entities.

  2. NETWORK DESIGN IN CLOSE-RANGE PHOTOGRAMMETRY WITH SHORT BASELINE IMAGES

    Directory of Open Access Journals (Sweden)

    L. Barazzetti

    2017-08-01

    Full Text Available The avaibility of automated software for image-based 3D modelling has changed the way people acquire images for photogrammetric applications. Short baseline images are required to match image points with SIFT-like algorithms, obtaining more images than those necessary for “old fashioned” photogrammetric projects based on manual measurements. This paper describes some considerations on network design for short baseline image sequences, especially on precision and reliability of bundle adjustment. Simulated results reveal that the large number of 3D points used for image orientation has very limited impact on network precision.

  3. Wavelength conversion technology

    DEFF Research Database (Denmark)

    Stubkjær, Kristian

    1998-01-01

    Optical wavelength conversion is currently attracting much interest. This is because it enables full flexibility and eases management of WDM fibre networks. The tutorial will review existing and potential application areas. Examples of node architectures and network demonstrators that use wavelen...

  4. Cassini Tour Atlas Automated Generation

    Science.gov (United States)

    Grazier, Kevin R.; Roumeliotis, Chris; Lange, Robert D.

    2011-01-01

    During the Cassini spacecraft s cruise phase and nominal mission, the Cassini Science Planning Team developed and maintained an online database of geometric and timing information called the Cassini Tour Atlas. The Tour Atlas consisted of several hundreds of megabytes of EVENTS mission planning software outputs, tables, plots, and images used by mission scientists for observation planning. Each time the nominal mission trajectory was altered or tweaked, a new Tour Atlas had to be regenerated manually. In the early phases of Cassini s Equinox Mission planning, an a priori estimate suggested that mission tour designers would develop approximately 30 candidate tours within a short period of time. So that Cassini scientists could properly analyze the science opportunities in each candidate tour quickly and thoroughly so that the optimal series of orbits for science return could be selected, a separate Tour Atlas was required for each trajectory. The task of manually generating the number of trajectory analyses in the allotted time would have been impossible, so the entire task was automated using code written in five different programming languages. This software automates the generation of the Cassini Tour Atlas database. It performs with one UNIX command what previously took a day or two of human labor.

  5. Lean automation development : applying lean principles to the automation development process

    OpenAIRE

    Granlund, Anna; Wiktorsson, Magnus; Grahn, Sten; Friedler, Niklas

    2014-01-01

    By a broad empirical study it is indicated that automation development show potential of improvement. In the paper, 13 lean product development principles are contrasted to the automation development process and it is suggested why and how these principles can facilitate, support and improve the automation development process. The paper summarises a description of what characterises a lean automation development process and what consequences it entails. Main differences compared to current pr...

  6. Systematic wavelength selection for improved multivariate spectral analysis

    Science.gov (United States)

    Thomas, Edward V.; Robinson, Mark R.; Haaland, David M.

    1995-01-01

    Methods and apparatus for determining in a biological material one or more unknown values of at least one known characteristic (e.g. the concentration of an analyte such as glucose in blood or the concentration of one or more blood gas parameters) with a model based on a set of samples with known values of the known characteristics and a multivariate algorithm using several wavelength subsets. The method includes selecting multiple wavelength subsets, from the electromagnetic spectral region appropriate for determining the known characteristic, for use by an algorithm wherein the selection of wavelength subsets improves the model's fitness of the determination for the unknown values of the known characteristic. The selection process utilizes multivariate search methods that select both predictive and synergistic wavelengths within the range of wavelengths utilized. The fitness of the wavelength subsets is determined by the fitness function F=.function.(cost, performance). The method includes the steps of: (1) using one or more applications of a genetic algorithm to produce one or more count spectra, with multiple count spectra then combined to produce a combined count spectrum; (2) smoothing the count spectrum; (3) selecting a threshold count from a count spectrum to select these wavelength subsets which optimize the fitness function; and (4) eliminating a portion of the selected wavelength subsets. The determination of the unknown values can be made: (1) noninvasively and in vivo; (2) invasively and in vivo; or (3) in vitro.

  7. Multi-Wavelength Photomagnetic Imaging for Oral Cancer

    Science.gov (United States)

    Marks, Michael

    In this study, a multi-wavelength Photomagnetic Imaging (PMI) system is developed and evaluated with experimental studies.. PMI measures temperature increases in samples illuminated by near-infrared light sources using magnetic resonance thermometry. A multiphysics solver combining light and heat transfer models the spatiotemporal distribution of the temperature change. The PMI system develop in this work uses three lasers of varying wavelength (785 nm, 808 nm, 860 nm) to heat the sample. By using multiple wavelengths, we enable the PMI system to quantify the relative concentrations of optical contrast in turbid media and monitor their distribution, at a higher resolution than conventional diffuse optical imaging. The data collected from agarose phantoms with multiple embedded contrast agents designed to simulate the optical properties of oxy- and deoxy-hemoglobin is presented. The reconstructed images demonstrate that multi-wavelength PMI can resolve this complex inclusion structure with high resolution and recover the concentration of each contrast agent with high quantitative accuracy. The modified multi-wavelength PMI system operates under the maximum skin exposure limits defined by the American National Standards Institute, to enable future clinical applications.

  8. Moving toward the automation of the systematic review process: a summary of discussions at the second meeting of International Collaboration for the Automation of Systematic Reviews (ICASR).

    Science.gov (United States)

    O'Connor, Annette M; Tsafnat, Guy; Gilbert, Stephen B; Thayer, Kristina A; Wolfe, Mary S

    2018-01-09

    The second meeting of the International Collaboration for Automation of Systematic Reviews (ICASR) was held 3-4 October 2016 in Philadelphia, Pennsylvania, USA. ICASR is an interdisciplinary group whose aim is to maximize the use of technology for conducting rapid, accurate, and efficient systematic reviews of scientific evidence. Having automated tools for systematic review should enable more transparent and timely review, maximizing the potential for identifying and translating research findings to practical application. The meeting brought together multiple stakeholder groups including users of summarized research, methodologists who explore production processes and systematic review quality, and technologists such as software developers, statisticians, and vendors. This diversity of participants was intended to ensure effective communication with numerous stakeholders about progress toward automation of systematic reviews and stimulate discussion about potential solutions to identified challenges. The meeting highlighted challenges, both simple and complex, and raised awareness among participants about ongoing efforts by various stakeholders. An outcome of this forum was to identify several short-term projects that participants felt would advance the automation of tasks in the systematic review workflow including (1) fostering better understanding about available tools, (2) developing validated datasets for testing new tools, (3) determining a standard method to facilitate interoperability of tools such as through an application programming interface or API, and (4) establishing criteria to evaluate the quality of tools' output. ICASR 2016 provided a beneficial forum to foster focused discussion about tool development and resources and reconfirm ICASR members' commitment toward systematic reviews' automation.

  9. Ultra-high accuracy optical testing: creating diffraction-limitedshort-wavelength optical systems

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, Kenneth A.; Naulleau, Patrick P.; Rekawa, Senajith B.; Denham, Paul E.; Liddle, J. Alexander; Gullikson, Eric M.; Jackson, KeithH.; Anderson, Erik H.; Taylor, John S.; Sommargren, Gary E.; Chapman,Henry N.; Phillion, Donald W.; Johnson, Michael; Barty, Anton; Soufli,Regina; Spiller, Eberhard A.; Walton, Christopher C.; Bajt, Sasa

    2005-08-03

    Since 1993, research in the fabrication of extreme ultraviolet (EUV) optical imaging systems, conducted at Lawrence Berkeley National Laboratory (LBNL) and Lawrence Livermore National Laboratory (LLNL), has produced the highest resolution optical systems ever made. We have pioneered the development of ultra-high-accuracy optical testing and alignment methods, working at extreme ultraviolet wavelengths, and pushing wavefront-measuring interferometry into the 2-20-nm wavelength range (60-600 eV). These coherent measurement techniques, including lateral shearing interferometry and phase-shifting point-diffraction interferometry (PS/PDI) have achieved RMS wavefront measurement accuracies of 0.5-1-{angstrom} and better for primary aberration terms, enabling the creation of diffraction-limited EUV optics. The measurement accuracy is established using careful null-testing procedures, and has been verified repeatedly through high-resolution imaging. We believe these methods are broadly applicable to the advancement of short-wavelength optical systems including space telescopes, microscope objectives, projection lenses, synchrotron beamline optics, diffractive and holographic optics, and more. Measurements have been performed on a tunable undulator beamline at LBNL's Advanced Light Source (ALS), optimized for high coherent flux; although many of these techniques should be adaptable to alternative ultraviolet, EUV, and soft x-ray light sources. To date, we have measured nine prototype all-reflective EUV optical systems with NA values between 0.08 and 0.30 (f/6.25 to f/1.67). These projection-imaging lenses were created for the semiconductor industry's advanced research in EUV photolithography, a technology slated for introduction in 2009-13. This paper reviews the methods used and our program's accomplishments to date.

  10. All-optical multi-wavelength conversion with negative power penalty by a commercial SOA-MZI for WDM wavelength multicast

    NARCIS (Netherlands)

    Yan, N.; Jung, H.D.; Tafur Monroy, I.; Waardt, de H.; Koonen, A.M.J.

    2007-01-01

    WDM wavelength multicast is demonstrated by all-optical multi-wavelength conversion at 10 Gb/s using a commercial SOA-MZI. We report for the first time simultaneous one-to-four conversion with negative power penalty of 1.84 dB.

  11. Both Automation and Paper.

    Science.gov (United States)

    Purcell, Royal

    1988-01-01

    Discusses the concept of a paperless society and the current situation in library automation. Various applications of automation and telecommunications are addressed, and future library automation is considered. Automation at the Monroe County Public Library in Bloomington, Indiana, is described as an example. (MES)

  12. Atomic layer deposition of absorbing thin films on nanostructured electrodes for short-wavelength infrared photosensing

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Jixian; Sutherland, Brandon R.; Hoogland, Sjoerd; Fan, Fengjia; Sargent, Edward H., E-mail: ted.sargent@utoronto.ca [Department of Electrical and Computer Engineering, University of Toronto, 10 King' s College Road, Toronto, Ontario M5S 3G4 (Canada); Kinge, Sachin [Advanced Technology, Materials and Research, Research and Development, Hoge Wei 33- Toyota Technical Centre, B-1930 Zaventem (Belgium)

    2015-10-12

    Atomic layer deposition (ALD), prized for its high-quality thin-film formation in the absence of high temperature or high vacuum, has become an industry standard for the large-area deposition of a wide array of oxide materials. Recently, it has shown promise in the formation of nanocrystalline sulfide films. Here, we demonstrate the viability of ALD lead sulfide for photodetection. Leveraging the conformal capabilities of ALD, we enhance the absorption without compromising the extraction efficiency in the absorbing layer by utilizing a ZnO nanowire electrode. The nanowires are first coated with a thin shunt-preventing TiO{sub 2} layer, followed by an infrared-active ALD PbS layer for photosensing. The ALD PbS photodetector exhibits a peak responsivity of 10{sup −2} A W{sup −1} and a shot-derived specific detectivity of 3 × 10{sup 9} Jones at 1530 nm wavelength.

  13. Effect of aspherical and yellow tinted intraocular lens on blue-on-yellow perimetry Efeito das lentes intraoculares asféricas e com pigmentação amarela na campimetria azul-amarelo

    Directory of Open Access Journals (Sweden)

    Rodrigo França de Espíndola

    2012-10-01

    Full Text Available PURPOSE: To investigate the possible effect of aspherical or yellow tinted intraocular lens (IOL on contrast sensitivity and blue-on-yellow perimetry. METHODS: This prospective randomized bilateral double-masked clinical study included 52 patients with visually significant bilateral cataracts divided in two groups; 25 patients (50 eyes received aspherical intraocular lens in one eye and spherical intraocular lens in the fellow eye; and 27 patients (54 eyes received ultraviolet and blue light filter (yellow tinted IOL implantation in one eye and acrylic ultraviolet filter IOL in the fellow eye. The primary outcome measures were contrast sensitivity and blue-on-yellow perimetry values (mean deviation [MD] and pattern standard deviation [PSD] investigated two years after surgery. The results were compared intra-individually. RESULTS: There was a statistically significant between-group (aspherical and spherical intraocular lens difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. There were no between-group significant differences (yellow tinted and clear intraocular lens under photopic or mesopic conditions. There was no statistically significant difference between all intraocular lens in MD or PSD. CONCLUSION: Contrast sensitivity was better under mesopic conditions with aspherical intraocular lens. Blue-on-yellow perimetry did not appear to be affected by aspherical or yellow tinted intraocular lens. Further studies with a larger sample should be carried out to confirm or not that hypotheses.OBJETIVO: Investigar a possibilidade de efeitos na sensibilidade ao contraste e nos resultados da campimetria azul-amarelo com implante de uma lente intraocular (LIO asférica ou de pigmentação amarela. MÉTODOS: Trata-se de um estudo prospectivo, randomizado, duplo-mascarado, envolvendo 52 pacientes portadores de catarata senil bilateral, divididos em dois grupos; 25

  14. JPLEX: Java Simplex Implementation with Branch-and-Bound Search for Automated Test Assembly

    Science.gov (United States)

    Park, Ryoungsun; Kim, Jiseon; Dodd, Barbara G.; Chung, Hyewon

    2011-01-01

    JPLEX, short for Java simPLEX, is an automated test assembly (ATA) program. It is a mixed integer linear programming (MILP) solver written in Java. It reads in a configuration file, solves the minimization problem, and produces an output file for postprocessing. It implements the simplex algorithm to create a fully relaxed solution and…

  15. Monochromatic Pupillometry in Unilateral Glaucoma Discloses no Adaptive Changes Subserved by the ipRGCs

    DEFF Research Database (Denmark)

    Nissen, Claus; Sander, Birgit Agnes; Milea, Dan

    2014-01-01

    PURPOSE: To detect signs of a possible adaptive mechanism of the intrinsically photosensitive ganglion cells in unilateral glaucoma. METHOD: Eleven patients with unilateral glaucoma, classified by automated perimetry (glaucoma: mean deviation ... in the glaucomatous eyes of unilateral glaucoma. No difference was detected between the pupillary light response of the unafflicted fellow eyes and that of a healthy, age-matched control group. Thus no sign of an adaptive mechanism was detected, neither in the glaucomatous nor in the unafflicted fellow eyes......, and consequently glaucoma appears to differ from non-arteritic anterior ischemic optic neuropathy....

  16. Evaluation of a glaucoma patient

    Science.gov (United States)

    Thomas, Ravi; Loibl, Klaus; Parikh, Rajul

    2011-01-01

    The diagnosis of glaucoma is usually made clinically and requires a comprehensive eye examination, including slit lamp, applanation tonometry, gonioscopy and dilated stereoscopic evaluation of the optic disc and retina. Automated perimetry is obtained if glaucoma is suspected. This establishes the presence of functional damage and provides a baseline for follow-up. Imaging techniques are not essential for the diagnosis but may have a role to play in the follow-up. We recommend a comprehensive eye examination for every clinic patient with the objective of detecting all potentially sight-threatening diseases, including glaucoma. PMID:21150033

  17. Automated Groundwater Screening

    International Nuclear Information System (INIS)

    Taylor, Glenn A.; Collard, Leonard B.

    2005-01-01

    The Automated Intruder Analysis has been extended to include an Automated Ground Water Screening option. This option screens 825 radionuclides while rigorously applying the National Council on Radiation Protection (NCRP) methodology. An extension to that methodology is presented to give a more realistic screening factor for those radionuclides which have significant daughters. The extension has the promise of reducing the number of radionuclides which must be tracked by the customer. By combining the Automated Intruder Analysis with the Automated Groundwater Screening a consistent set of assumptions and databases is used. A method is proposed to eliminate trigger values by performing rigorous calculation of the screening factor thereby reducing the number of radionuclides sent to further analysis. Using the same problem definitions as in previous groundwater screenings, the automated groundwater screening found one additional nuclide, Ge-68, which failed the screening. It also found that 18 of the 57 radionuclides contained in NCRP Table 3.1 failed the screening. This report describes the automated groundwater screening computer application

  18. Spectral shifts of mammalian ultraviolet-sensitive pigments (short wavelength-sensitive opsin 1) are associated with eye length and photic niche evolution.

    Science.gov (United States)

    Emerling, Christopher A; Huynh, Hieu T; Nguyen, Minh A; Meredith, Robert W; Springer, Mark S

    2015-11-22

    Retinal opsin photopigments initiate mammalian vision when stimulated by light. Most mammals possess a short wavelength-sensitive opsin 1 (SWS1) pigment that is primarily sensitive to either ultraviolet or violet light, leading to variation in colour perception across species. Despite knowledge of both ultraviolet- and violet-sensitive SWS1 classes in mammals for 25 years, the adaptive significance of this variation has not been subjected to hypothesis testing, resulting in minimal understanding of the basis for mammalian SWS1 spectral tuning evolution. Here, we gathered data on SWS1 for 403 mammal species, including novel SWS1 sequences for 97 species. Ancestral sequence reconstructions suggest that the most recent common ancestor of Theria possessed an ultraviolet SWS1 pigment, and that violet-sensitive pigments evolved at least 12 times in mammalian history. We also observed that ultraviolet pigments, previously considered to be a rarity, are common in mammals. We then used phylogenetic comparative methods to test the hypotheses that the evolution of violet-sensitive SWS1 is associated with increased light exposure, extended longevity and longer eye length. We discovered that diurnal mammals and species with longer eyes are more likely to have violet-sensitive pigments and less likely to possess UV-sensitive pigments. We hypothesize that (i) as mammals evolved larger body sizes, they evolved longer eyes, which limited transmittance of ultraviolet light to the retina due to an increase in Rayleigh scattering, and (ii) as mammals began to invade diurnal temporal niches, they evolved lenses with low UV transmittance to reduce chromatic aberration and/or photo-oxidative damage. © 2015 The Author(s).

  19. Comparison of Diagnostic Accuracy between Octopus 900 and Goldmann Kinetic Visual Fields

    Directory of Open Access Journals (Sweden)

    Fiona J. Rowe

    2014-01-01

    Full Text Available Purpose. To determine diagnostic accuracy of kinetic visual field assessment by Octopus 900 perimetry compared with Goldmann perimetry. Methods. Prospective cross section evaluation of 40 control subjects with full visual fields and 50 patients with known visual field loss. Comparison of test duration and area measurement of isopters for Octopus 3, 5, and 10°/sec stimulus speeds. Comparison of test duration and type of visual field classification for Octopus versus Goldmann perimetry. Results were independently graded for presence/absence of field defect and for type and location of defect. Statistical evaluation comprised of ANOVA and paired t test for evaluation of parametric data with Bonferroni adjustment. Bland Altman and Kappa tests were used for measurement of agreement between data. Results. Octopus 5°/sec perimetry had comparable test duration to Goldmann perimetry. Octopus perimetry reliably detected type and location of visual field loss with visual fields matched to Goldmann results in 88.8% of results (K=0.775. Conclusions. Kinetic perimetry requires individual tailoring to ensure accuracy. Octopus perimetry was reproducible for presence/absence of visual field defect. Our screening protocol when using Octopus perimetry is 5°/sec for determining boundaries of peripheral isopters and 3°/sec for blind spot mapping with further evaluation of area of field loss for defect depth and size.

  20. Wavelength stabilized multi-kW diode laser systems

    Science.gov (United States)

    Köhler, Bernd; Unger, Andreas; Kindervater, Tobias; Drovs, Simon; Wolf, Paul; Hubrich, Ralf; Beczkowiak, Anna; Auch, Stefan; Müntz, Holger; Biesenbach, Jens

    2015-03-01

    We report on wavelength stabilized high-power diode laser systems with enhanced spectral brightness by means of Volume Holographic Gratings. High-power diode laser modules typically have a relatively broad spectral width of about 3 to 6 nm. In addition the center wavelength shifts by changing the temperature and the driving current, which is obstructive for pumping applications with small absorption bandwidths. Wavelength stabilization of high-power diode laser systems is an important method to increase the efficiency of diode pumped solid-state lasers. It also enables power scaling by dense wavelength multiplexing. To ensure a wide locking range and efficient wavelength stabilization the parameters of the Volume Holographic Grating and the parameters of the diode laser bar have to be adapted carefully. Important parameters are the reflectivity of the Volume Holographic Grating, the reflectivity of the diode laser bar as well as its angular and spectral emission characteristics. In this paper we present detailed data on wavelength stabilized diode laser systems with and without fiber coupling in the spectral range from 634 nm up to 1533 nm. The maximum output power of 2.7 kW was measured for a fiber coupled system (1000 μm, NA 0.22), which was stabilized at a wavelength of 969 nm with a spectral width of only 0.6 nm (90% value). Another example is a narrow line-width diode laser stack, which was stabilized at a wavelength of 1533 nm with a spectral bandwidth below 1 nm and an output power of 835 W.

  1. Wavelength sweepable laser source

    DEFF Research Database (Denmark)

    2014-01-01

    Wavelength sweepable laser source is disclosed, wherein the laser source is a semiconductor laser source adapted for generating laser light at a lasing wavelength. The laser source comprises a substrate, a first reflector, and a second reflector. The first and second reflector together defines...... and having a rest position, the second reflector and suspension together defining a microelectromechanical MEMS oscillator. The MEMS oscillator has a resonance frequency and is adapted for oscillating the second reflector on either side of the rest position.; The laser source further comprises electrical...... connections adapted for applying an electric field to the MEMS oscillator. Furthermore, a laser source system and a method of use of the laser source are disclosed....

  2. Wavelength conversion techniques and devices

    DEFF Research Database (Denmark)

    Danielsen, Søren Lykke; Mikkelsen, Benny; Hansen, Peter Bukhave

    1997-01-01

    Taking into account the requirements to the converters e.g., bit rate transparency (at least up to 10 Gbit/s), polarisation independence, wavelength independence, moderate input power levels, high signal-to-noise ratio and high extinction ratio interferometric wavelength convertors are very...... interesting for use in WDM optical fibre networks. However, the perfect converter has probably not yet been fabricated and new techniques such as conversion relying on cross-absorption modulation in electro-absorption modulators might also be considered in pursue of effective conversion devices...

  3. Wavelength standards in the infrared

    CERN Document Server

    Rao, KN

    2012-01-01

    Wavelength Standards in the Infrared is a compilation of wavelength standards suitable for use with high-resolution infrared spectrographs, including both emission and absorption standards. The book presents atomic line emission standards of argon, krypton, neon, and xenon. These atomic line emission standards are from the deliberations of Commission 14 of the International Astronomical Union, which is the recognized authority for such standards. The text also explains the techniques employed in determining spectral positions in the infrared. One of the techniques used includes the grating con

  4. Automated model building

    CERN Document Server

    Caferra, Ricardo; Peltier, Nicholas

    2004-01-01

    This is the first book on automated model building, a discipline of automated deduction that is of growing importance Although models and their construction are important per se, automated model building has appeared as a natural enrichment of automated deduction, especially in the attempt to capture the human way of reasoning The book provides an historical overview of the field of automated deduction, and presents the foundations of different existing approaches to model construction, in particular those developed by the authors Finite and infinite model building techniques are presented The main emphasis is on calculi-based methods, and relevant practical results are provided The book is of interest to researchers and graduate students in computer science, computational logic and artificial intelligence It can also be used as a textbook in advanced undergraduate courses

  5. Analysis of calibration-free wavelength-scanned wavelength modulation spectroscopy for practical gas sensing using tunable diode lasers

    Science.gov (United States)

    Sun, K.; Chao, X.; Sur, R.; Goldenstein, C. S.; Jeffries, J. B.; Hanson, R. K.

    2013-12-01

    A novel strategy has been developed for analysis of wavelength-scanned, wavelength modulation spectroscopy (WMS) with tunable diode lasers (TDLs). The method simulates WMS signals to compare with measurements to determine gas properties (e.g., temperature, pressure and concentration of the absorbing species). Injection-current-tuned TDLs have simultaneous wavelength and intensity variation, which severely complicates the Fourier expansion of the simulated WMS signal into harmonics of the modulation frequency (fm). The new method differs from previous WMS analysis strategies in two significant ways: (1) the measured laser intensity is used to simulate the transmitted laser intensity and (2) digital lock-in and low-pass filter software is used to expand both simulated and measured transmitted laser intensities into harmonics of the modulation frequency, WMS-nfm (n = 1, 2, 3,…), avoiding the need for an analytic model of intensity modulation or Fourier expansion of the simulated WMS harmonics. This analysis scheme is valid at any optical depth, modulation index, and at all values of scanned-laser wavelength. The method is demonstrated and validated with WMS of H2O dilute in air (1 atm, 296 K, near 1392 nm). WMS-nfm harmonics for n = 1 to 6 are extracted and the simulation and measurements are found in good agreement for the entire WMS lineshape. The use of 1f-normalization strategies to realize calibration-free wavelength-scanned WMS is also discussed.

  6. Performance evaluation of distributed wavelength assignment in WDM optical networks

    Science.gov (United States)

    Hashiguchi, Tomohiro; Wang, Xi; Morikawa, Hiroyuki; Aoyama, Tomonori

    2004-04-01

    In WDM wavelength routed networks, prior to a data transfer, a call setup procedure is required to reserve a wavelength path between the source-destination node pairs. A distributed approach to a connection setup can achieve a very high speed, while improving the reliability and reducing the implementation cost of the networks. However, along with many advantages, several major challenges have been posed by the distributed scheme in how the management and allocation of wavelength could be efficiently carried out. In this thesis, we apply a distributed wavelength assignment algorithm named priority based wavelength assignment (PWA) that was originally proposed for the use in burst switched optical networks to the problem of reserving wavelengths of path reservation protocols in the distributed control optical networks. Instead of assigning wavelengths randomly, this approach lets each node select the "safest" wavelengths based on the information of wavelength utilization history, thus unnecessary future contention is prevented. The simulation results presented in this paper show that the proposed protocol can enhance the performance of the system without introducing any apparent drawbacks.

  7. Impact of beacon wavelength on phase-compensation performance

    Science.gov (United States)

    Enterline, Allison A.; Spencer, Mark F.; Burrell, Derek J.; Brennan, Terry J.

    2017-09-01

    This study evaluates the effects of beacon-wavelength mismatch on phase-compensation performance. In general, beacon-wavelength mismatch occurs at the system level because the beacon-illuminator laser (BIL) and high-energy laser (HEL) are often at different wavelengths. Such is the case, for example, when using an aperture sharing element to isolate the beam-control sensor suite from the blinding nature of the HEL. With that said, this study uses the WavePlex Toolbox in MATLAB® to model ideal spherical wave propagation through various atmospheric-turbulence conditions. To quantify phase-compensation performance, we also model a nominal adaptive-optics (AO) system. We achieve correction from a Shack-Hartmann wavefront sensor and continuous-face-sheet deformable mirror using a least-squares phase reconstruction algorithm in the Fried geometry and a leaky integrator control law. To this end, we plot the power in the bucket metric as a function of BIL-HEL wavelength difference. Our initial results show that positive BIL-HEL wavelength differences achieve better phase compensation performance compared to negative BIL-HEL wavelength differences (i.e., red BILs outperform blue BILs). This outcome is consistent with past results.

  8. Temperature Characteristics of Monolithically Integrated Wavelength-Selectable Light Sources

    International Nuclear Information System (INIS)

    Han Liang-Shun; Zhu Hong-Liang; Zhang Can; Ma Li; Liang Song; Wang Wei

    2013-01-01

    The temperature characteristics of monolithically integrated wavelength-selectable light sources are experimentally investigated. The wavelength-selectable light sources consist of four distributed feedback (DFB) lasers, a multimode interferometer coupler, and a semiconductor optical amplifier. The oscillating wavelength of the DFB laser could be modulated by adjusting the device operating temperature. A wavelength range covering over 8.0nm is obtained with stable single-mode operation by selecting the appropriate laser and chip temperature. The thermal crosstalk caused by the lateral heat spreading between lasers operating simultaneously is evaluated by oscillating-wavelength shift. The thermal crosstalk approximately decreases exponentially as the increasing distance between lasers

  9. Analysis of the fluctuation-induced excess dc conductivity of epitaxial YBa2Cu3O7 films: Influence of a short-wavelength cutoff in the fluctuation spectrum

    International Nuclear Information System (INIS)

    Hopfengaertner, R.; Hensel, B.; Saemann-Ischenko, G.

    1991-01-01

    Measurements of the temperature dependence of the in-plane dc conductivity on various high-quality epitaxial YBa 2 Cu 3 O 7 films are presented. The rounding of the resistivity in the transition region has been analyzed in terms of the anisotropic Aslamazov-Larkin (AL), Lawrence-Doniach (LD), and Maki-Thompson theories. In the framework of the time-dependent Ginzburg-Landau (GL) approach we have investigated the influence of a short-wavelength cutoff parameter in the fluctuation spectrum of the AL and LD term. In both theories this physically reasonable cutoff leads to a considerable reduction of the predicted excess dc conductivity at higher temperatures. Moreover, the three-dimensional anisotropic AL term, taking the cutoff into account, predicts nearly the same excess conductivity as the original LD term, although these two approaches describe different systems. A good agreement between experimental data and LD as well as the modified three-dimensional anisotropic AL term was found in the region 1.01T c ≤T≤1.1T c . The zero-temperature GL coherence length ξ c (0) has been estimated to be about 1.5 A

  10. The impact of coherent synchrotron radiation on the beam transport of short bunches

    International Nuclear Information System (INIS)

    Li, R.

    1999-01-01

    Designs for next-generation accelerator, such as future linear colliders and short-wavelength FEL drivers, require beams of short (mm-length or smaller) bunches and high charge (nC-regime). As such a high charge microbunch traverses magnetic bends, the curvature effect on the bunch self-interaction, by way of coherent synchrotron radiation (CSR) and space charge force, may cause serious emittance degradation. This impact of CSR on the beam transport of short bunches has raised significant concern in the design of future machines and led to extensive investigations. This paper reviews some of the recent progress in the understanding of the CSR effect, presents analysis of and computational work on the CSR impact on short bunch transport, and addresses remaining issues

  11. 78 FR 53466 - Modification of Two National Customs Automation Program (NCAP) Tests Concerning Automated...

    Science.gov (United States)

    2013-08-29

    ... Customs Automation Program (NCAP) Tests Concerning Automated Commercial Environment (ACE) Document Image... National Customs Automation Program (NCAP) tests concerning document imaging, known as the Document Image... the National Customs Automation Program (NCAP) tests concerning document imaging, known as the...

  12. Spectral domain optical coherence tomography as an effective screening test for hydroxychloroquine retinopathy (the "flying saucer" sign).

    Science.gov (United States)

    Chen, Eric; Brown, David M; Benz, Matthew S; Fish, Richard H; Wong, Tien P; Kim, Rosa Y; Major, James C

    2010-10-21

    While the long-term incidence of hydroxychloroquine (HCQ) retinopathy is low, there remains no definitive clinical screening test to recognize HCQ toxicity before ophthalmoscopic fundus changes or visual symptoms. Patients receiving HCQ were evaluated with spectral domain optical coherence tomography (SD OCT) to assess the feasibility of identifying HCQ retinopathy at an early stage. Twenty-five patients referred for the evaluation of hydroxychloroquine toxicity underwent a comprehensive ocular examination, Humphrey visual field (HVF) perimetry, time domain OCT, and SD OCT. Some patients with screening abnormalities also underwent further diagnostic testing at the discretion of the treating providers. Five patients were found to have SD OCT findings corresponding to HCQ toxicity and retinal damage as seen by clinical exam and/or HVF perimetry. Two patients with advanced toxicity were found to have significant outer retina disruption in the macula on SD OCT. Three patients with early HCQ toxicity and HVF 10-2 perifoveal defects were found to have loss of the perifoveal photoreceptor inner segment/outer segment (IS/OS) junction with intact outer retina directly under the fovea, creating the "flying saucer" sign. While two of these three patients had early ophthalmoscopic fundus changes, one had none. Outer retinal abnormalities including perifoveal photoreceptor IS/OS junction disruption can be identified by SD OCT in early HCQ toxicity, sometimes even before ophthalmoscopic fundus changes are apparent. SD OCT may have a potential complementary role in screening for HCQ retinopathy due to its quick acquisition and because it is more objective than automated perimetry.

  13. Optimization of automation: III. Development of optimization method for determining automation rate in nuclear power plants

    International Nuclear Information System (INIS)

    Lee, Seung Min; Kim, Jong Hyun; Kim, Man Cheol; Seong, Poong Hyun

    2016-01-01

    Highlights: • We propose an appropriate automation rate that enables the best human performance. • We analyze the shortest working time considering Situation Awareness Recovery (SAR). • The optimized automation rate is estimated by integrating the automation and ostracism rate estimation methods. • The process to derive the optimized automation rate is demonstrated through case studies. - Abstract: Automation has been introduced in various industries, including the nuclear field, because it is commonly believed that automation promises greater efficiency, lower workloads, and fewer operator errors through reducing operator errors and enhancing operator and system performance. However, the excessive introduction of automation has deteriorated operator performance due to the side effects of automation, which are referred to as Out-of-the-Loop (OOTL), and this is critical issue that must be resolved. Thus, in order to determine the optimal level of automation introduction that assures the best human operator performance, a quantitative method of optimizing the automation is proposed in this paper. In order to propose the optimization method for determining appropriate automation levels that enable the best human performance, the automation rate and ostracism rate, which are estimation methods that quantitatively analyze the positive and negative effects of automation, respectively, are integrated. The integration was conducted in order to derive the shortest working time through considering the concept of situation awareness recovery (SAR), which states that the automation rate with the shortest working time assures the best human performance. The process to derive the optimized automation rate is demonstrated through an emergency operation scenario-based case study. In this case study, four types of procedures are assumed through redesigning the original emergency operating procedure according to the introduced automation and ostracism levels. Using the

  14. A fast, automated, semideterministic weight windows generator for MCNP

    International Nuclear Information System (INIS)

    Mickael, M.W.

    1995-01-01

    A fast automated method is developed to estimate particle importance in the Los Alamos Carlo code MCNP. It provides an automated and efficient way of predicting and setting up an important map for the weight windows technique. A short analog simulation is first performed to obtain effective group parameters based on the input description of the problem. A solution of the multigroup time-dependent adjoint diffusion equation is then used to estimate particle importance. At any point in space, time, and energy, the particle importance is determined, based on the calculated parameters, and used as the lower limit of the weight window. The method has been tested for neutron, photon, and coupled neutron-photon problems. Significant improvement in the simulation efficiency is obtained using this technique at no additional computer time and with no prior knowledge of the nature of the problem. Moreover, time and angular importance that are not available yet in MCNP are easily implemented in this method

  15. Wavelength conversion, time demultiplexing and multicasting based on cross-phase modulation and four-wave mixing in dispersion-flattened highly nonlinear photonic crystal fiber

    International Nuclear Information System (INIS)

    Hui, Zhan-Qiang; Zhang, Jian-Guo

    2012-01-01

    We propose the use of cross-phase modulation (XPM) and four-wave mixing (FWM) in dispersion-flattened highly nonlinear photonic crystal fibers (HNL-PCFs) to implement the functionalities of wavelength conversion, simultaneous time demultiplexing and wavelength multicasting in optical time-division multiplexing (OTDM) systems. The experiments on wavelength conversion at 80 Gbit s −1 and OTDM demultiplexing from 80 to 10 Gbit s −1 with wavelength multicasting of two channels are successfully demonstrated to validate the proposed scheme, which are carried out by using two segments of dispersion-flattened HNL-PCFs with lengths of 100 and 50 m, respectively. Moreover, the bit error rate (BER) performance is also measured. The results show that our designed system can achieve a power penalty of less than 4.6 dB for two multicasting channels with a 24 nm wavelength span at the BER of 10 −9 when compared with the 10 Gbit/s back-to-back measurement. The proposed system is transparent to bit rate since only an ultrafast third-order nonlinear effect is used. The resulting configuration is compact, robust and reliable, benefiting from the use of dispersion-flattened HNL-PCFs with short lengths. This also makes the proposed system more flexible in the operational wavelengths than those based on dispersion-shifted fibers and traditional highly nonlinear fibers. (paper)

  16. Non-universality of critical exponents in the paraconductivity of short-coherence-length superconductors

    International Nuclear Information System (INIS)

    Gauzzi, A.

    1993-01-01

    The Aslamazov-Larkin paraconductivity term is calculated in the case of sufficiently small superconducting coherence length. It is found that the critical exponent of paraconductivity depends on the short-wavelength cut-off of the fluctuation spectrum in the whole Ginzburg-Landau mean-field region. Hence, it is predicted that the Aslamazov-Larkin universal relation between the critical exponent of paraconductivity and the dimensionality of the superconducting state is no longer valid in short-coherence-length superconductors. This prediction is confirmed by paraconductivity measurements on cuprate superconductors. (orig.)

  17. A Multi-Wavelength IR Laser for Space Applications

    Science.gov (United States)

    Li, Steven X.; Yu, Anthony W.; Sun, Xiaoli; Fahey, Molly E.; Numata, Kenji; Krainak, Michael A.

    2017-01-01

    We present a laser technology development with space flight heritage to generate laser wavelengths in the near- to mid-infrared (NIR to MIR) for space lidar applications. Integrating an optical parametric crystal to the LOLA (Lunar Orbiter Laser Altimeter) laser transmitter design affords selective laser wavelengths from NIR to MIR that are not easily obtainable from traditional diode pumped solid-state lasers. By replacing the output coupler of the LOLA laser with a properly designed parametric crystal, we successfully demonstrated a monolithic intra-cavity optical parametric oscillator (iOPO) laser based on all high technology readiness level (TRL) subsystems and components. Several desired wavelengths have been generated including 2.1 microns, 2.7 microns and 3.4 microns. This laser can also be used in trace-gas remote sensing, as many molecules possess their unique vibrational transitions in NIR to MIR wavelength region, as well as in time-of-flight mass spectrometer where desorption of samples using MIR laser wavelengths have been successfully demonstrated.

  18. Optimal wavelength band clustering for multispectral iris recognition.

    Science.gov (United States)

    Gong, Yazhuo; Zhang, David; Shi, Pengfei; Yan, Jingqi

    2012-07-01

    This work explores the possibility of clustering spectral wavelengths based on the maximum dissimilarity of iris textures. The eventual goal is to determine how many bands of spectral wavelengths will be enough for iris multispectral fusion and to find these bands that will provide higher performance of iris multispectral recognition. A multispectral acquisition system was first designed for imaging the iris at narrow spectral bands in the range of 420 to 940 nm. Next, a set of 60 human iris images that correspond to the right and left eyes of 30 different subjects were acquired for an analysis. Finally, we determined that 3 clusters were enough to represent the 10 feature bands of spectral wavelengths using the agglomerative clustering based on two-dimensional principal component analysis. The experimental results suggest (1) the number, center, and composition of clusters of spectral wavelengths and (2) the higher performance of iris multispectral recognition based on a three wavelengths-bands fusion.

  19. In-vacuum long-wavelength macromolecular crystallography.

    Science.gov (United States)

    Wagner, Armin; Duman, Ramona; Henderson, Keith; Mykhaylyk, Vitaliy

    2016-03-01

    Structure solution based on the weak anomalous signal from native (protein and DNA) crystals is increasingly being attempted as part of synchrotron experiments. Maximizing the measurable anomalous signal by collecting diffraction data at longer wavelengths presents a series of technical challenges caused by the increased absorption of X-rays and larger diffraction angles. A new beamline at Diamond Light Source has been built specifically for collecting data at wavelengths beyond the capability of other synchrotron macromolecular crystallography beamlines. Here, the theoretical considerations in support of the long-wavelength beamline are outlined and the in-vacuum design of the endstation is discussed, as well as other hardware features aimed at enhancing the accuracy of the diffraction data. The first commissioning results, representing the first in-vacuum protein structure solution, demonstrate the promising potential of the beamline.

  20. World-wide distribution automation systems

    International Nuclear Information System (INIS)

    Devaney, T.M.

    1994-01-01

    A worldwide power distribution automation system is outlined. Distribution automation is defined and the status of utility automation is discussed. Other topics discussed include a distribution management system, substation feeder, and customer functions, potential benefits, automation costs, planning and engineering considerations, automation trends, databases, system operation, computer modeling of system, and distribution management systems

  1. WIDAFELS flexible automation systems

    International Nuclear Information System (INIS)

    Shende, P.S.; Chander, K.P.; Ramadas, P.

    1990-01-01

    After discussing the various aspects of automation, some typical examples of various levels of automation are given. One of the examples is of automated production line for ceramic fuel pellets. (M.G.B.)

  2. Multiple wavelength X-ray monochromators

    International Nuclear Information System (INIS)

    Steinmeyer, P.A.

    1992-01-01

    An improved apparatus and method is provided for separating input x-ray radiation containing first and second x-ray wavelengths into spatially separate first and second output radiation which contain the first and second x-ray wavelengths, respectively. The apparatus includes a crystalline diffractor which includes a first set of parallel crystal planes, where each of the planes is spaced a predetermined first distance from one another. The crystalline diffractor also includes a second set of parallel crystal planes inclined at an angle with respect to the first set of crystal planes where each of the planes of the second set of parallel crystal planes is spaced a predetermined second distance from one another. In one embodiment, the crystalline diffractor is comprised of a single crystal. In a second embodiment, the crystalline diffractor is comprised of a stack of two crystals. In a third embodiment, the crystalline diffractor includes a single crystal that is bent for focusing the separate first and second output x-ray radiation wavelengths into separate focal points. 3 figs

  3. Automation in Clinical Microbiology

    Science.gov (United States)

    Ledeboer, Nathan A.

    2013-01-01

    Historically, the trend toward automation in clinical pathology laboratories has largely bypassed the clinical microbiology laboratory. In this article, we review the historical impediments to automation in the microbiology laboratory and offer insight into the reasons why we believe that we are on the cusp of a dramatic change that will sweep a wave of automation into clinical microbiology laboratories. We review the currently available specimen-processing instruments as well as the total laboratory automation solutions. Lastly, we outline the types of studies that will need to be performed to fully assess the benefits of automation in microbiology laboratories. PMID:23515547

  4. Virtual automation.

    Science.gov (United States)

    Casis, E; Garrido, A; Uranga, B; Vives, A; Zufiaurre, C

    2001-01-01

    Total laboratory automation (TLA) can be substituted in mid-size laboratories by a computer sample workflow control (virtual automation). Such a solution has been implemented in our laboratory using PSM, software developed in cooperation with Roche Diagnostics (Barcelona, Spain), to this purpose. This software is connected to the online analyzers and to the laboratory information system and is able to control and direct the samples working as an intermediate station. The only difference with TLA is the replacement of transport belts by personnel of the laboratory. The implementation of this virtual automation system has allowed us the achievement of the main advantages of TLA: workload increase (64%) with reduction in the cost per test (43%), significant reduction in the number of biochemistry primary tubes (from 8 to 2), less aliquoting (from 600 to 100 samples/day), automation of functional testing, drastic reduction of preanalytical errors (from 11.7 to 0.4% of the tubes) and better total response time for both inpatients (from up to 48 hours to up to 4 hours) and outpatients (from up to 10 days to up to 48 hours). As an additional advantage, virtual automation could be implemented without hardware investment and significant headcount reduction (15% in our lab).

  5. The test beamline of the European Spallation Source – Instrumentation development and wavelength frame multiplication

    International Nuclear Information System (INIS)

    Woracek, R.; Hofmann, T.; Bulat, M.; Sales, M.; Habicht, K.; Andersen, K.; Strobl, M.

    2016-01-01

    The European Spallation Source (ESS), scheduled to start operation in 2020, is aiming to deliver the most intense neutron beams for experimental research of any facility worldwide. Its long pulse time structure implies significant differences for instrumentation compared to other spallation sources which, in contrast, are all providing short neutron pulses. In order to enable the development of methods and technology adapted to this novel type of source well in advance of the first instruments being constructed at ESS, a test beamline (TBL) was designed and built at the BER II research reactor at Helmholtz-Zentrum Berlin (HZB). Operating the TBL shall provide valuable experience in order to allow for a smooth start of operations at ESS. The beamline is capable of mimicking the ESS pulse structure by a double chopper system and provides variable wavelength resolution as low as 0.5% over a wide wavelength band between 1.6 Å and 10 Å by a dedicated wavelength frame multiplication (WFM) chopper system. WFM is proposed for several ESS instruments to allow for flexible time-of-flight resolution. Hence, ESS will benefit from the TBL which offers unique possibilities for testing methods and components. This article describes the main capabilities of the instrument, its performance as experimentally verified during the commissioning, and its relevance to currently starting ESS instrumentation projects.

  6. The test beamline of the European Spallation Source – Instrumentation development and wavelength frame multiplication

    Energy Technology Data Exchange (ETDEWEB)

    Woracek, R., E-mail: robin.woracek@esss.se [European Spallation Source ESS ERIC, P.O. Box 176, SE-22100 Lund (Sweden); Hofmann, T.; Bulat, M. [Helmholtz-Zentrum Berlin für Materialien und Energie, Hahn-Meitner Platz 1, 14109 Berlin (Germany); Sales, M. [Technical University of Denmark, Fysikvej, 2800 Kgs. Lyngby (Denmark); Habicht, K. [Helmholtz-Zentrum Berlin für Materialien und Energie, Hahn-Meitner Platz 1, 14109 Berlin (Germany); Andersen, K. [European Spallation Source ESS ERIC, P.O. Box 176, SE-22100 Lund (Sweden); Strobl, M. [European Spallation Source ESS ERIC, P.O. Box 176, SE-22100 Lund (Sweden); Technical University of Denmark, Fysikvej, 2800 Kgs. Lyngby (Denmark)

    2016-12-11

    The European Spallation Source (ESS), scheduled to start operation in 2020, is aiming to deliver the most intense neutron beams for experimental research of any facility worldwide. Its long pulse time structure implies significant differences for instrumentation compared to other spallation sources which, in contrast, are all providing short neutron pulses. In order to enable the development of methods and technology adapted to this novel type of source well in advance of the first instruments being constructed at ESS, a test beamline (TBL) was designed and built at the BER II research reactor at Helmholtz-Zentrum Berlin (HZB). Operating the TBL shall provide valuable experience in order to allow for a smooth start of operations at ESS. The beamline is capable of mimicking the ESS pulse structure by a double chopper system and provides variable wavelength resolution as low as 0.5% over a wide wavelength band between 1.6 Å and 10 Å by a dedicated wavelength frame multiplication (WFM) chopper system. WFM is proposed for several ESS instruments to allow for flexible time-of-flight resolution. Hence, ESS will benefit from the TBL which offers unique possibilities for testing methods and components. This article describes the main capabilities of the instrument, its performance as experimentally verified during the commissioning, and its relevance to currently starting ESS instrumentation projects.

  7. Optical cross-connect circuit using hitless wavelength selective switch.

    Science.gov (United States)

    Goebuchi, Yuta; Hisada, Masahiko; Kato, Tomoyuki; Kokubun, Yasuo

    2008-01-21

    We have proposed and demonstrated the basic elements of a full matrix optical switching circuit (cross-connect circuit) using a hitless wavelength selective switch (WSS). The cross-connect circuits are made of a multi-wavelength channel selective switch consisting of cascaded hitless WSSs, and a multi-port switch. These switching elements are realized through the individual Thermo-Optic (TO) tuning of a series-coupled microring resonator, and can switch arbitrary wavelength channels without blocking other wavelength channels during tuning. We demonstrate a four wavelength selective switch using a parallel topology of double series coupled microring resonators and a three wavelength selective switch using a parallel topology of quadruple series coupled microring resonators. Since the spectrum shape of quadruple series coupled microring is much more box-like than the double series, a high extinction ratio of 39.0-46.6 dB and low switching cross talk of 19.3-24.5 dB were achieved.

  8. Automation of Test Cases for Web Applications : Automation of CRM Test Cases

    OpenAIRE

    Seyoum, Alazar

    2012-01-01

    The main theme of this project was to design a test automation framework for automating web related test cases. Automating test cases designed for testing a web interface provide a means of improving a software development process by shortening the testing phase in the software development life cycle. In this project an existing AutoTester framework and iMacros test automation tools were used. CRM Test Agent was developed to integrate AutoTester to iMacros and to enable the AutoTester,...

  9. Dynamical resonance shift and unification of resonances in short-pulse laser-cluster interaction

    Science.gov (United States)

    Mahalik, S. S.; Kundu, M.

    2018-06-01

    Pronounced maximum absorption of laser light irradiating a rare-gas or metal cluster is widely expected during the linear resonance (LR) when Mie-plasma wavelength λM of electrons equals the laser wavelength λ . On the contrary, by performing molecular dynamics (MD) simulations of an argon cluster irradiated by short 5-fs (FWHM) laser pulses it is revealed that, for a given laser pulse energy and a cluster, at each peak intensity there exists a λ —shifted from the expected λM—that corresponds to a unified dynamical LR at which evolution of the cluster happens through very efficient unification of possible resonances in various stages, including (i) the LR in the initial time of plasma creation, (ii) the LR in the Coulomb expanding phase in the later time, and (iii) anharmonic resonance in the marginally overdense regime for a relatively longer pulse duration, leading to maximum laser absorption accompanied by maximum removal of electrons from cluster and also maximum allowed average charge states for the argon cluster. Increasing the laser intensity, the absorption maxima is found to shift to a higher wavelength in the band of λ ≈(1 -1.5 ) λM than permanently staying at the expected λM. A naive rigid sphere model also corroborates the wavelength shift of the absorption peak as found in MD and unequivocally proves that maximum laser absorption in a cluster happens at a shifted λ in the marginally overdense regime of λ ≈(1 -1.5 ) λM instead of λM of LR. The present study is important for guiding an optimal condition laser-cluster interaction experiment in the short-pulse regime.

  10. Construction of a single/multiple wavelength RZ optical pulse source at 40 GHz by use of wavelength conversion in a high-nonlinearity DSF-NOLM

    DEFF Research Database (Denmark)

    Yu, Jianjun; Yujun, Qian; Jeppesen, Palle

    2001-01-01

    A single or multiple wavelength RZ optical pulse source at 40 GHz is successfully obtained by using wavelength conversion in a nonlinear optical loop mirror consisting of high nonlinearity-dispersion shifted fiber.......A single or multiple wavelength RZ optical pulse source at 40 GHz is successfully obtained by using wavelength conversion in a nonlinear optical loop mirror consisting of high nonlinearity-dispersion shifted fiber....

  11. Absorption spectrum of DNA for wavelengths greater than 300 nm

    International Nuclear Information System (INIS)

    Sutherland, J.C.; Griffin, K.P.

    1981-01-01

    Although DNA absorption at wavelengths greater than 300 nm is much weaker than that at shorter wavelengths, this absorption seems to be responsible for much of the biological damage caused by solar radiation of wavelengths less than 320 nm. Accurate measurement of the absorption spectrum of DNA above 300 nm is complicated by turbidity characteristic of concentrated solutions of DNA. We have measured the absorption spectra of DNA from calf thymus, Clostridium perfringens, Escherichia coli, Micrococcus luteus, salmon testis, and human placenta using procedures which separate optical density due to true absorption from that due to turbidity. Above 300 nm, the relative absorption of DNA increases as a function of guanine-cytosine content, presumably because the absorption of guanine is much greater than the absorption of adenine at these wavelengths. This result suggests that the photophysical processes which follow absorption of a long-wavelength photon may, on the average, differ from those induced by shorter-wavelength photons. It may also explain the lower quantum yield for the killing of cells by wavelengths above 300 nm compared to that by shorter wavelengths

  12. Investigation of concept of efficient short wavelength laser. Interim progress report, 1 April 1977-30 April 1978

    Energy Technology Data Exchange (ETDEWEB)

    Piper, L.G.; Krech, R.H.; Taylor, R.L.

    1978-05-01

    Under this program PSI is investigating the photolytic decomposition of a class of endoergic molecules - azides. Because these compounds contain substantial chemical energy, they offer a potentially more efficient approach for the production of electronically excited fragments. The goal of the present program was to acquire sufficient data and understanding of certain fundamental processes to permit the critical evaluation of this approach for laser development. An apparatus was built to study the wavelength-selected photolysis of gaseous, covalent azides. The photolysis source is a frequency doubled, tuneable dye laser. Detection of fragment species is accomplished by observation of primary fluorescence, or by laser-induced fluorescence (LIF) using a second tuneable dye laser. The design of the apparatus is discussed in detail.

  13. Sub-wavelength resonances in polygonal metamaterial cylinders

    DEFF Research Database (Denmark)

    Arslanagic, Samel; Breinbjerg, Olav

    2008-01-01

    It has been shown that the sub-wavelength resonances of circular MTM cylinders also occur for polygonal MTM cylinders. This is the case for lossless and non-dispersive cylinders as well as lossy and dispersive cylinders. The sub-wavelength resonances are thus not limited to structures of canonical...

  14. An Automation Planning Primer.

    Science.gov (United States)

    Paynter, Marion

    1988-01-01

    This brief planning guide for library automation incorporates needs assessment and evaluation of options to meet those needs. A bibliography of materials on automation planning and software reviews, library software directories, and library automation journals is included. (CLB)

  15. Automation in Immunohematology

    Directory of Open Access Journals (Sweden)

    Meenu Bajpai

    2012-01-01

    Full Text Available There have been rapid technological advances in blood banking in South Asian region over the past decade with an increasing emphasis on quality and safety of blood products. The conventional test tube technique has given way to newer techniques such as column agglutination technique, solid phase red cell adherence assay, and erythrocyte-magnetized technique. These new technologies are adaptable to automation and major manufacturers in this field have come up with semi and fully automated equipments for immunohematology tests in the blood bank. Automation improves the objectivity and reproducibility of tests. It reduces human errors in patient identification and transcription errors. Documentation and traceability of tests, reagents and processes and archiving of results is another major advantage of automation. Shifting from manual methods to automation is a major undertaking for any transfusion service to provide quality patient care with lesser turnaround time for their ever increasing workload. This article discusses the various issues involved in the process.

  16. Sensitivity and Specificity of Swedish Interactive Threshold Algorithm and Standard Full Threshold Perimetry in Primary Open-angle Glaucoma.

    Science.gov (United States)

    Bamdad, Shahram; Beigi, Vahid; Sedaghat, Mohammad Reza

    2017-01-01

    Perimetry is one of the mainstays in glaucoma diagnosis and treatment. Various strategies offer different accuracies in glaucoma testing. Our aim was to determine and compare the diagnostic sensitivity and specificity of Swedish Interactive Threshold Algorithm (SITA) Fast and Standard Full Threshold (SFT) strategies of the Humphrey Field Analyzer (HFA) in identifying patients with visual field defect in glaucoma disease. This prospective observational case series study was conducted in a university-based eye hospital. A total of 37 eyes of 20 patients with glaucoma were evaluated using the central 30-2 program and both the SITA Fast and SFT strategies. Both strategies were performed for each strategy in each session and for four times in a 2-week period. Data were analyzed using the Student's t-test, analysis of variance, and chi-square test. The SITA Fast and SFT strategies had similar sensitivity of 93.3%. The specificity of SITA Fast and SFT strategies was 57.4% and 71.4% respectively. The mean duration of SFT tests was 14.6 minutes, and that of SITA Fast tests was 5.45 minutes (a statistically significant 62.5% reduction). In gray scale plots, visual field defect was less deep in SITA Fast than in SFT; however, more points had significant defect (p 0.5% and p deviation plots in SITA Fast than in SFT; these differences were not clinically significant. In conclusion, the SITA Fast strategy showed higher sensitivity for detection of glaucoma compared to the SFT strategy, yet with reduced specificity; however, the shorter test duration makes it a more acceptable choice in many clinical situations, especially for children, elderly, and those with musculoskeletal diseases.

  17. Development of Nuclear Power Plant Safety Evaluation Method for the Automation Algorithm Application

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Geun; Seong, Poong Hyun [KAIST, Daejeon (Korea, Republic of)

    2016-10-15

    It is commonly believed that replacing human operators to the automated system would guarantee greater efficiency, lower workloads, and fewer human error. Conventional machine learning techniques are considered as not capable to handle complex situations in NPP. Due to these kinds of issues, automation is not actively adopted although human error probability drastically increases during abnormal situations in NPP due to overload of information, high workload, and short time available for diagnosis. Recently, new machine learning techniques, which are known as ‘deep learning’ techniques have been actively applied to many fields, and the deep learning technique-based artificial intelligences (AIs) are showing better performance than conventional AIs. In 2015, deep Q-network (DQN) which is one of the deep learning techniques was developed and applied to train AI that automatically plays various Atari 2800 games, and this AI surpassed the human-level playing in many kind of games. Also in 2016, ‘Alpha-Go’, which was developed by ‘Google Deepmind’ based on deep learning technique to play the game of Go (i.e. Baduk), was defeated Se-dol Lee who is the World Go champion with score of 4:1. By the effort for reducing human error in NPPs, the ultimate goal of this study is the development of automation algorithm which can cover various situations in NPPs. As the first part, quantitative and real-time NPP safety evaluation method is being developed in order to provide the training criteria for automation algorithm. For that, EWS concept of medical field was adopted, and the applicability is investigated in this paper. Practically, the application of full automation (i.e. fully replaces human operators) may requires much more time for the validation and investigation of side-effects after the development of automation algorithm, and so the adoption in the form of full automation will take long time.

  18. Development of Nuclear Power Plant Safety Evaluation Method for the Automation Algorithm Application

    International Nuclear Information System (INIS)

    Kim, Seung Geun; Seong, Poong Hyun

    2016-01-01

    It is commonly believed that replacing human operators to the automated system would guarantee greater efficiency, lower workloads, and fewer human error. Conventional machine learning techniques are considered as not capable to handle complex situations in NPP. Due to these kinds of issues, automation is not actively adopted although human error probability drastically increases during abnormal situations in NPP due to overload of information, high workload, and short time available for diagnosis. Recently, new machine learning techniques, which are known as ‘deep learning’ techniques have been actively applied to many fields, and the deep learning technique-based artificial intelligences (AIs) are showing better performance than conventional AIs. In 2015, deep Q-network (DQN) which is one of the deep learning techniques was developed and applied to train AI that automatically plays various Atari 2800 games, and this AI surpassed the human-level playing in many kind of games. Also in 2016, ‘Alpha-Go’, which was developed by ‘Google Deepmind’ based on deep learning technique to play the game of Go (i.e. Baduk), was defeated Se-dol Lee who is the World Go champion with score of 4:1. By the effort for reducing human error in NPPs, the ultimate goal of this study is the development of automation algorithm which can cover various situations in NPPs. As the first part, quantitative and real-time NPP safety evaluation method is being developed in order to provide the training criteria for automation algorithm. For that, EWS concept of medical field was adopted, and the applicability is investigated in this paper. Practically, the application of full automation (i.e. fully replaces human operators) may requires much more time for the validation and investigation of side-effects after the development of automation algorithm, and so the adoption in the form of full automation will take long time

  19. Automated Budget System -

    Data.gov (United States)

    Department of Transportation — The Automated Budget System (ABS) automates management and planning of the Mike Monroney Aeronautical Center (MMAC) budget by providing enhanced capability to plan,...

  20. Bioprocessing automation in cell therapy manufacturing: Outcomes of special interest group automation workshop.

    Science.gov (United States)

    Ball, Oliver; Robinson, Sarah; Bure, Kim; Brindley, David A; Mccall, David

    2018-04-01

    Phacilitate held a Special Interest Group workshop event in Edinburgh, UK, in May 2017. The event brought together leading stakeholders in the cell therapy bioprocessing field to identify present and future challenges and propose potential solutions to automation in cell therapy bioprocessing. Here, we review and summarize discussions from the event. Deep biological understanding of a product, its mechanism of action and indication pathogenesis underpin many factors relating to bioprocessing and automation. To fully exploit the opportunities of bioprocess automation, therapeutics developers must closely consider whether an automation strategy is applicable, how to design an 'automatable' bioprocess and how to implement process modifications with minimal disruption. Major decisions around bioprocess automation strategy should involve all relevant stakeholders; communication between technical and business strategy decision-makers is of particular importance. Developers should leverage automation to implement in-process testing, in turn applicable to process optimization, quality assurance (QA)/ quality control (QC), batch failure control, adaptive manufacturing and regulatory demands, but a lack of precedent and technical opportunities can complicate such efforts. Sparse standardization across product characterization, hardware components and software platforms is perceived to complicate efforts to implement automation. The use of advanced algorithmic approaches such as machine learning may have application to bioprocess and supply chain optimization. Automation can substantially de-risk the wider supply chain, including tracking and traceability, cryopreservation and thawing and logistics. The regulatory implications of automation are currently unclear because few hardware options exist and novel solutions require case-by-case validation, but automation can present attractive regulatory incentives. Copyright © 2018 International Society for Cellular Therapy

  1. Can the Roche hemolysis index be used for automated determination of cell-free hemoglobin? A comparison to photometric assays.

    Science.gov (United States)

    Petrova, Darinka Todorova; Cocisiu, Gabriela Ariadna; Eberle, Christoph; Rhode, Karl-Heinz; Brandhorst, Gunnar; Walson, Philip D; Oellerich, Michael

    2013-09-01

    The aim of this study was to develop a novel method for automated quantification of cell-free hemoglobin (fHb) based on the HI (Roche Diagnostics). The novel fHb method based on the HI was correlated with fHb measured using the triple wavelength methods of both Harboe [fHb, g/L = (0.915 * HI + 2.634)/100] and Fairbanks et al. [fHb, g/L = (0.917 * HI + 2.131)/100]. fHb concentrations were estimated from the HI using the Roche Modular automated platform in self-made and commercially available quality controls, as well as samples from a proficiency testing scheme (INSTAND). The fHb using Roche automated HI results were then compared to results obtained using the traditional spectrophotometric assays for one hundred plasma samples with varying degrees of hemolysis, lipemia and/or bilirubinemia. The novel method using automated HI quantification on the Roche Modular clinical chemistry platform correlated well with results using the classical methods in the 100 patient samples (Harboe: r = 0.9284; Fairbanks et al.: r = 0.9689) and recovery was good for self-made controls. However, commercially available quality controls showed poor recovery due to an unidentified matrix problem. The novel method produced reliable determination of fHb in samples without interferences. However, poor recovery using commercially available fHb quality control samples currently greatly limits its usefulness. © 2013.

  2. Structural changes of the macula and optic nerve head in the remaining eyes after enucleation for retinoblastoma: an optical coherence tomography study.

    Science.gov (United States)

    Said, Azza Mohamed Ahmed; Elbayomi, Ahmed Mohamed; Shaat, Ashraf Abdelsalam Kandeel

    2017-12-16

    To describe objectively the possible structural changes of the macula and optic nerve head in the free eyes of unilateral cured retinoblastoma patients and, also after enucleation using spectral domain optical coherence tomography. A cross sectional study involving 60 patients subdivided into three groups; 15 unilateral RB patients in whom enucleation was indicated as a sole treatment performed earlier in life [(study group (I)], 15 unilateral RB patients who had completely regressed disease with a preserved eye [(study group (II)] and 30 age and sex matched healthy controls. The remaining and free eyes in study groups and right eyes of control group had full ophthalmological examination, static automated perimetry and optical coherence tomography of the macula and optic nerve head. In study group (II); a significant thinning of total macula, central fovea, ganglion cell layer (GCL), ganglion cell complex (GCC), and some sectors of outer nuclear layer (P- values ≤0.05) was found with no significant difference in peripapillary nerve fiber layer (pRNFL) thickness and optic nerve head parameters compared to the control group and the study group (I). A significantly thickened total macula, GCL, GCC, and pRNFL in study group (I) compared to study group (II). Thickened pRNFL was significantly correlated to standard automated perimetry pattern deviations. No significant difference was found between study group (I) and control group. Retinoblastoma eyes characterized by thinning of central fovea, GCL, GCC compared to the control group. After unilateral enucleation, increased GCC and pRNFL thicknesses were detected compared to retinoblastoma group.

  3. Automating Hyperspectral Data for Rapid Response in Volcanic Emergencies

    Science.gov (United States)

    Davies, Ashley G.; Doubleday, Joshua R.; Chien, Steve A.

    2013-01-01

    In a volcanic emergency, time is of the essence. It is vital to quantify eruption parameters (thermal emission, effusion rate, location of activity) and distribute this information as quickly as possible to decision-makers in order to enable effective evaluation of eruption-related risk and hazard. The goal of this work was to automate and streamline processing of spacecraft hyperspectral data, automate product generation, and automate distribution of products. Visible and Short-Wave Infrared Images of volcanic eruption in Iceland in May 2010." class="caption" align="right">The software rapidly processes hyperspectral data, correcting for incident sunlight where necessary, and atmospheric transmission; detects thermally anomalous pixels; fits data with model black-body thermal emission spectra to determine radiant flux; calculates atmospheric convection thermal removal; and then calculates total heat loss. From these results, an estimation of effusion rate is made. Maps are generated of thermal emission and location (see figure). Products are posted online, and relevant parties notified. Effusion rate data are added to historical record and plotted to identify spikes in activity for persistently active eruptions. The entire process from start to end is autonomous. Future spacecraft, especially those in deep space, can react to detection of transient processes without the need to communicate with Earth, thus increasing science return. Terrestrially, this removes the need for human intervention.

  4. Takeover Time in Highly Automated Vehicles: Noncritical Transitions to and From Manual Control.

    Science.gov (United States)

    Eriksson, Alexander; Stanton, Neville A

    2017-06-01

    The aim of this study was to review existing research into driver control transitions and to determine the time it takes drivers to resume control from a highly automated vehicle in noncritical scenarios. Contemporary research has moved from an inclusive design approach to adhering only to mean/median values when designing control transitions in automated driving. Research into control transitions in highly automated driving has focused on urgent scenarios where drivers are given a relatively short time span to respond to a request to resume manual control. We found a paucity in research into more frequent scenarios for control transitions, such as planned exits from highway systems. Twenty-six drivers drove two scenarios with an automated driving feature activated. Drivers were asked to read a newspaper, or to monitor the system, and to relinquish, or resume, control from the automation when prompted by vehicle systems. Significantly longer control transition times were found between driving with and without secondary tasks. Control transition times were substantially longer than those reported in the peer-reviewed literature. We found that drivers take longer to resume control when under no time pressure compared with that reported in the literature. Moreover, we found that drivers occupied by a secondary task exhibit larger variance and slower responses to requests to resume control. Workload scores implied optimal workload. Intra- and interindividual differences need to be accommodated by vehicle manufacturers and policy makers alike to ensure inclusive design of contemporary systems and safety during control transitions.

  5. Automated processing integrated with a microflow cytometer for pathogen detection in clinical matrices.

    Science.gov (United States)

    Golden, J P; Verbarg, J; Howell, P B; Shriver-Lake, L C; Ligler, F S

    2013-02-15

    A spinning magnetic trap (MagTrap) for automated sample processing was integrated with a microflow cytometer capable of simultaneously detecting multiple targets to provide an automated sample-to-answer diagnosis in 40 min. After target capture on fluorescently coded magnetic microspheres, the magnetic trap automatically concentrated the fluorescently coded microspheres, separated the captured target from the sample matrix, and exposed the bound target sequentially to biotinylated tracer molecules and streptavidin-labeled phycoerythrin. The concentrated microspheres were then hydrodynamically focused in a microflow cytometer capable of 4-color analysis (two wavelengths for microsphere identification, one for light scatter to discriminate single microspheres and one for phycoerythrin bound to the target). A three-fold decrease in sample preparation time and an improved detection limit, independent of target preconcentration, was demonstrated for detection of Escherichia coli 0157:H7 using the MagTrap as compared to manual processing. Simultaneous analysis of positive and negative controls, along with the assay reagents specific for the target, was used to obtain dose-response curves, demonstrating the potential for quantification of pathogen load in buffer and serum. Published by Elsevier B.V.

  6. Longitudinal Diagnostics for Short Electron Beam Bunches

    Energy Technology Data Exchange (ETDEWEB)

    Loos, H.; /SLAC

    2010-06-11

    Single-pass free electron lasers require high peak currents from ultra-short electron bunches to reach saturation and an accurate measurement of bunch length and longitudinal bunch profile is necessary to control the bunch compression process from low to high beam energy. The various state-of-the-art diagnostics methods from ps to fs time scales using coherent radiation detection, RF deflection, and other techniques are presented. The use of linear accelerators as drivers for free electron lasers (FEL) and the advent of single-pass (SASE) FELs has driven the development of a wide range of diagnostic techniques for measuring the length and longitudinal distribution of short and ultra-short electron bunches. For SASE FELs the radiation power and the length of the undulator needed to achieve saturation depend strongly on the charge density of the electron beam. In the case of X-ray FELs, this requires the accelerator to produce ultra-high brightness beams with micron size transverse normalized emittances and peak currents of several kA through several stages of magnetic bunch compression. Different longitudinal diagnostics are employed to measure the peak current and bunch profile along these stages. The measurement techniques can be distinguished into different classes. Coherent methods detect the light emitted from the beam by some coherent radiation process (spectroscopic measurement), or directly measure the Coulomb field traveling with the beam (electro-optic). Phase space manipulation techniques map the time coordinate onto a transverse dimension and then use conventional transverse beam diagnostics (transverse deflector, rf zero-phasing). Further methods measure the profile or duration of an incoherent light pulse emitted by the bunch at wavelengths much shorted than the bunch length (streak camera, fluctuation technique) or modulate the electron beam at an optical wavelength and then generate a narrow bandwidth radiation pulse with the longitudinal profile of

  7. Delivery of Patient-Reported Outcome Instruments by Automated Mobile Phone Text Messaging.

    Science.gov (United States)

    Anthony, Christopher A; Lawler, Ericka A; Glass, Natalie A; McDonald, Katelyn; Shah, Apurva S

    2017-11-01

    Patient-reported outcome (PRO) instruments allow patients to interpret their health and are integral in evaluating orthopedic treatments and outcomes. The purpose of this study was to define: (1) correlation between PROs collected by automated delivery of text messages on mobile phones compared with paper delivery; and (2) patient use characteristics of a technology platform utilizing automated delivery of text messages on mobile phones. Paper versions of the 12-Item Short Form Health Survey (SF-12) and the short form of the Disabilities of the Arm, Shoulder and Hand (QuickDASH) were completed by patients in orthopedic hand and upper extremity clinics. Over the next 48 hours, the same patients also completed the mobile phone portion of the study outside of the clinic which included text message delivery of the SF-12 and QuickDASH, assigned in a random order. Correlations between paper and text message delivery of the 2 PROs were assessed. Among 72 patients, the intraclass correlation coefficient (ICC) between the written and mobile phone delivery of QuickDASH was 0.91 (95% confidence interval [CI], 0.85-0.95). The ICC between the paper and mobile phone delivery of the SF-12 physical health composite score was 0.88 (95% CI, 0.79-0.93) and 0.86 (95% CI, 0.75-0.92) for the SF-12 mental health composite score. We find that text message delivery using mobile phones permits valid assessment of SF-12 and QuickDASH scores. The findings suggest that software-driven automated delivery of text communication to patients via mobile phones may be a valid method to obtain other PRO scores in orthopedic patients.

  8. Reflective variable optical attenuators and fibre ring lasers for wavelength-division multiplexing systems

    Science.gov (United States)

    Liu, He Liang

    the common silicate fibres were used. Due to the high solubility of erbium ions in bismuth oxide based erbium-doped fibre (Bi-EDF), a stable and short-cavity fibre ring laser was realized by employing only 0.85 m of Bi-EDF. Ultrawide continuous wavelength tuning range over 100 nm was obtained by using a tuning MEMS filter or scanning fibre FP filter. A very narrow linewidth, single-longitudinal mode fibre ring laser, using an unpumped EDF acting as saturable absorber in the cavity, was realized. The linewidth of the fibre ring laser was measured by two optical mixing methods and about 1.17 kHz linewidth was measuring by the delayed self-heterodyne technique. (Abstract shortened by UMI.)

  9. Semi-automated retinal vessel analysis in nonmydriatic fundus photography.

    Science.gov (United States)

    Schuster, Alexander Karl-Georg; Fischer, Joachim Ernst; Vossmerbaeumer, Urs

    2014-02-01

    Funduscopic assessment of the retinal vessels may be used to assess the health status of microcirculation and as a component in the evaluation of cardiovascular risk factors. Typically, the evaluation is restricted to morphological appreciation without strict quantification. Our purpose was to develop and validate a software tool for semi-automated quantitative analysis of retinal vasculature in nonmydriatic fundus photography. matlab software was used to develop a semi-automated image recognition and analysis tool for the determination of the arterial-venous (A/V) ratio in the central vessel equivalent on 45° digital fundus photographs. Validity and reproducibility of the results were ascertained using nonmydriatic photographs of 50 eyes from 25 subjects recorded from a 3DOCT device (Topcon Corp.). Two hundred and thirty-three eyes of 121 healthy subjects were evaluated to define normative values. A software tool was developed using image thresholds for vessel recognition and vessel width calculation in a semi-automated three-step procedure: vessel recognition on the photograph and artery/vein designation, width measurement and calculation of central retinal vessel equivalents. Mean vessel recognition rate was 78%, vessel class designation rate 75% and reproducibility between 0.78 and 0.91. Mean A/V ratio was 0.84. Application on a healthy norm cohort showed high congruence with prior published manual methods. Processing time per image was one minute. Quantitative geometrical assessment of the retinal vasculature may be performed in a semi-automated manner using dedicated software tools. Yielding reproducible numerical data within a short time leap, this may contribute additional value to mere morphological estimates in the clinical evaluation of fundus photographs. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  10. All-optical 40 Gbit/s compact integrated interferometric wavelength converter

    DEFF Research Database (Denmark)

    Jørgensen, Carsten; Danielsen, Søren Lykke; Hansen, Peter Bukhave

    1997-01-01

    An interferometric Michelson wavelength converter is presented that combines a speed-optimized semiconductor optical amplifier technology with the benefits of the integrated interferometer showing 40-Gbit/s wavelength conversion. The optimized wavelength converter demonstrates noninverted converted...

  11. 78 FR 66039 - Modification of National Customs Automation Program Test Concerning Automated Commercial...

    Science.gov (United States)

    2013-11-04

    ... Customs Automation Program Test Concerning Automated Commercial Environment (ACE) Cargo Release (Formerly...) plan to both rename and modify the National Customs Automation Program (NCAP) test concerning the... data elements required to obtain release for cargo transported by air. The test will now be known as...

  12. Automation-aided Task Loads Index based on the Automation Rate Reflecting the Effects on Human Operators in NPPs

    International Nuclear Information System (INIS)

    Lee, Seungmin; Seong, Poonghyun; Kim, Jonghyun

    2013-01-01

    Many researchers have found that a high automation rate does not guarantee high performance. Therefore, to reflect the effects of automation on human performance, a new estimation method of the automation rate that considers the effects of automation on human operators in nuclear power plants (NPPs) was suggested. These suggested measures express how much automation support human operators but it cannot express the change of human operators' workload, whether the human operators' workload is increased or decreased. Before considering automation rates, whether the adopted automation is good or bad might be estimated in advance. In this study, to estimate the appropriateness of automation according to the change of the human operators' task loads, automation-aided task loads index is suggested based on the concept of the suggested automation rate. To insure plant safety and efficiency on behalf of human operators, various automation systems have been installed in NPPs, and many works which were previously conducted by human operators can now be supported by computer-based operator aids. According to the characteristics of the automation types, the estimation method of the system automation and the cognitive automation rate were suggested. The proposed estimation method concentrates on the effects of introducing automation, so it directly express how much the automated system support human operators. Based on the suggested automation rates, the way to estimate how much the automated system can affect the human operators' cognitive task load is suggested in this study. When there is no automation, the calculated index is 1, and it means there is no change of human operators' task load

  13. Innovative strategy for effective critical laboratory result management: end-to-end process using automation and manual call centre.

    Science.gov (United States)

    Ti, Lian Kah; Ang, Sophia Bee Leng; Saw, Sharon; Sethi, Sunil Kumar; Yip, James W L

    2012-08-01

    Timely reporting and acknowledgement are crucial steps in critical laboratory results (CLR) management. The authors previously showed that an automated pathway incorporating short messaging system (SMS) texts, auto-escalation, and manual telephone back-up improved the rate and speed of physician acknowledgement compared with manual telephone calling alone. This study investigated if it also improved the rate and speed of physician intervention to CLR and whether utilising the manual back-up affected intervention rates. Data from seven audits between November 2007 and January 2011 were analysed. These audits were carried out to assess the robustness of CLR reporting process in the authors' institution. Comparisons were made in the rate and speed of acknowledgement and intervention between the audits performed before and after automation. Using the automation audits, the authors compared intervention data between communication with SMS only and when manual intervention was required. 1680 CLR were reported during the audit periods. Automation improved the rate (100% vs 84.2%; pautomation audits, the use of SMS only did not improve physician intervention rates. The automated communication pathway improved physician intervention rate and time in tandem with improved acknowledgement rate and time when compared with manual telephone calling. The use of manual intervention to augment automation did not adversely affect physician intervention rate, implying that an end-to-end pathway was more important than automation alone.

  14. Pulsed hybrid dual wavelength Y-branch-DFB laser-tapered amplifier system suitable for water vapor detection at 965 nm with 16 W peak power

    Science.gov (United States)

    Vu, Thi N.; Klehr, Andreas; Sumpf, Bernd; Hoffmann, Thomas; Liero, Armin; Tränkle, Günther

    2016-03-01

    A master oscillator power amplifier system emitting alternatingly at two neighbored wavelengths around 965 nm is presented. As master oscillator (MO) a Y-branch DFB-laser is used. The two branches, which can be individually controlled, deliver the two wavelengths needed for a differential absorption measurement of water vapor. Adjusting the current through the DFB sections, the wavelength can be adjusted with respect to the targeted either "on" or "off" resonance, respectively wavelength λon or wavelength λoff. The emission of this laser is amplified in a tapered amplifier (TA). The ridge waveguide section of the TA acts as optical gate to generate short pulses with duration of 8 ns at a repetition rate of 25 kHz, the flared section is used for further amplification to reach peak powers up to 16 W suitable for micro-LIDAR (Light Detection and Ranging). The necessary pulse current supply user a GaN-transistor based driver electronics placed close to the power amplifier (PA). The spectral properties of the emission of the MO are preserved by the PA. A spectral line width smaller than 10 pm and a side mode suppression ratio (SMSR) of 37 dB are measured. These values meet the demands for water vapor absorption measurements under atmospheric conditions.

  15. Asleep at the automated wheel-Sleepiness and fatigue during highly automated driving.

    Science.gov (United States)

    Vogelpohl, Tobias; Kühn, Matthias; Hummel, Thomas; Vollrath, Mark

    2018-03-20

    Due to the lack of active involvement in the driving situation and due to monotonous driving environments drivers with automation may be prone to become fatigued faster than manual drivers (e.g. Schömig et al., 2015). However, little is known about the progression of fatigue during automated driving and its effects on the ability to take back manual control after a take-over request. In this driving simulator study with Nö=ö60 drivers we used a three factorial 2ö×ö2ö×ö12 mixed design to analyze the progression (12ö×ö5ömin; within subjects) of driver fatigue in drivers with automation compared to manual drivers (between subjects). Driver fatigue was induced as either mainly sleep related or mainly task related fatigue (between subjects). Additionally, we investigated the drivers' reactions to a take-over request in a critical driving scenario to gain insights into the ability of fatigued drivers to regain manual control and situation awareness after automated driving. Drivers in the automated driving condition exhibited facial indicators of fatigue after 15 to 35ömin of driving. Manual drivers only showed similar indicators of fatigue if they suffered from a lack of sleep and then only after a longer period of driving (approx. 40ömin). Several drivers in the automated condition closed their eyes for extended periods of time. In the driving with automation condition mean automation deactivation times after a take-over request were slower for a certain percentage (about 30%) of the drivers with a lack of sleep (Mö=ö3.2; SDö=ö2.1ös) compared to the reaction times after a long drive (Mö=ö2.4; SDö=ö0.9ös). Drivers with automation also took longer than manual drivers to first glance at the speed display after a take-over request and were more likely to stay behind a braking lead vehicle instead of overtaking it. Drivers are unable to stay alert during extended periods of automated driving without non-driving related tasks. Fatigued drivers could

  16. Evaluation of a glaucoma patient

    Directory of Open Access Journals (Sweden)

    Thomas Ravi

    2011-12-01

    Full Text Available The diagnosis of glaucoma is usually made clinically and requires a comprehensive eye examination, including slit lamp, applanation tonometry, gonioscopy and dilated stereoscopic evaluation of the optic disc and retina. Automated perimetry is obtained if glaucoma is suspected. This establishes the presence of functional damage and provides a baseline for follow-up. Imaging techniques are not essential for the diagnosis but may have a role to play in the follow-up. We recommend a comprehensive eye examination for every clinic patient with the objective of detecting all potentially sight-threatening diseases, including glaucoma.

  17. Procedure automation: the effect of automated procedure execution on situation awareness and human performance

    International Nuclear Information System (INIS)

    Andresen, Gisle; Svengren, Haakan; Heimdal, Jan O.; Nilsen, Svein; Hulsund, John-Einar; Bisio, Rossella; Debroise, Xavier

    2004-04-01

    As advised by the procedure workshop convened in Halden in 2000, the Halden Project conducted an experiment on the effect of automation of Computerised Procedure Systems (CPS) on situation awareness and human performance. The expected outcome of the study was to provide input for guidance on CPS design, and to support the Halden Project's ongoing research on human reliability analysis. The experiment was performed in HAMMLAB using the HAMBO BWR simulator and the COPMA-III CPS. Eight crews of operators from Forsmark 3 and Oskarshamn 3 participated. Three research questions were investigated: 1) Does procedure automation create Out-Of-The-Loop (OOTL) performance problems? 2) Does procedure automation affect situation awareness? 3) Does procedure automation affect crew performance? The independent variable, 'procedure configuration', had four levels: paper procedures, manual CPS, automation with breaks, and full automation. The results showed that the operators experienced OOTL problems in full automation, but that situation awareness and crew performance (response time) were not affected. One possible explanation for this is that the operators monitored the automated procedure execution conscientiously, something which may have prevented the OOTL problems from having negative effects on situation awareness and crew performance. In a debriefing session, the operators clearly expressed their dislike for the full automation condition, but that automation with breaks could be suitable for some tasks. The main reason why the operators did not like the full automation was that they did not feel being in control. A qualitative analysis addressing factors contributing to response time delays revealed that OOTL problems did not seem to cause delays, but that some delays could be explained by the operators having problems with the freeze function of the CPS. Also other factors such as teamwork and operator tendencies were of importance. Several design implications were drawn

  18. Span Restoration in Optical Networks with Limited Wavelength Conversion

    DEFF Research Database (Denmark)

    Ruepp, Sarah Renée; Buron, Jakob Due; Andriolli, N

    2007-01-01

    Next generation optical networks provide functionalities to dynamically provision and recover connections, while emerging technologies allow for the conversion between wavelengths. These devices are however expensive and hence it is likely that only few are deployed throughout the network...... converter-saving wavelength assignment in GMPLS networks. The converter saving property of the Suggested Vector is particularly desirable in span restoration, where the pre-failure path stubs have to be merged to the restoration path at the failure-adjacent nodes. In order to avoid wavelength conversion....... Furthermore, we describe different scenarios to extend the suggested vector wavelength assignment scheme to multi-domain networks with focus on span restoration....

  19. Automation-aided Task Loads Index based on the Automation Rate Reflecting the Effects on Human Operators in NPPs

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seungmin; Seong, Poonghyun [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Kim, Jonghyun [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2013-05-15

    Many researchers have found that a high automation rate does not guarantee high performance. Therefore, to reflect the effects of automation on human performance, a new estimation method of the automation rate that considers the effects of automation on human operators in nuclear power plants (NPPs) was suggested. These suggested measures express how much automation support human operators but it cannot express the change of human operators' workload, whether the human operators' workload is increased or decreased. Before considering automation rates, whether the adopted automation is good or bad might be estimated in advance. In this study, to estimate the appropriateness of automation according to the change of the human operators' task loads, automation-aided task loads index is suggested based on the concept of the suggested automation rate. To insure plant safety and efficiency on behalf of human operators, various automation systems have been installed in NPPs, and many works which were previously conducted by human operators can now be supported by computer-based operator aids. According to the characteristics of the automation types, the estimation method of the system automation and the cognitive automation rate were suggested. The proposed estimation method concentrates on the effects of introducing automation, so it directly express how much the automated system support human operators. Based on the suggested automation rates, the way to estimate how much the automated system can affect the human operators' cognitive task load is suggested in this study. When there is no automation, the calculated index is 1, and it means there is no change of human operators' task load.

  20. Emission wavelength of multilayer distributed feedback dye lasers

    DEFF Research Database (Denmark)

    Vannahme, Christoph; Smith, Cameron L. C.; Brøkner Christiansen, Mads

    2012-01-01

    Precise emission wavelength modeling is essential for understanding and optimization of distributed feedback (DFB) lasers. An analytical approach for determining the emission wavelength based on setting the propagation constant of the Bragg condition and solving for the resulting slab waveguide m...

  1. Wavelength encoding technique for particle analyses in hematology analyzer

    Science.gov (United States)

    Rongeat, Nelly; Brunel, Patrick; Gineys, Jean-Philippe; Cremien, Didier; Couderc, Vincent; Nérin, Philippe

    2011-07-01

    The aim of this study is to combine multiple excitation wavelengths in order to improve accuracy of fluorescence characterization of labeled cells. The experimental demonstration is realized with a hematology analyzer based on flow cytometry and a CW laser source emitting two visible wavelengths. A given optical encoding associated to each wavelength allows fluorescence identification coming from specific fluorochromes and avoiding the use of noisy compensation method.

  2. Wavelength comparison for laser induced breakdown spectroscopy caries detection

    Science.gov (United States)

    Amaral, Marcello M.; Raele, Marcus P.; Ana, Patrícia A.; Núñez, Sílvia C.; Zamataro, Claudia B.; Zezell, Denise M.

    2018-02-01

    Laser Induced Breakdown Spectroscopy (LIBS) is a technique capable to perform elemental analyses of a variety of samples, independent of matter state. Other spectroscopy techniques may require a destructive and time-consuming sample preparation. On the other hand, LIBS is a less destructive technique with no (or considerably less) sample preparation, using a relatively simple experimental setup. LIBS also provides a multielement analysis into one single spectrum acquisition, applying a Nd:YAG short-pulsed laser to ensure the stoichiometry between the sample and the generated plasma. LIBS have been applied on the study of carious lesions using a Nd:YAG into its fundamental emission at 1064 nm. It was shown that ratio of P/Ca and Zn/Ca can be used to monitor the cariogenic process. Another minor elements, e.g. C and Cu, associated with bacteria biofilm were also measured with the Nd:YAG laser. The fundamental wavelength emission (1064 nm) of Nd:YAG is coincident with a hydroxyapatite transmission window and it may affect the result. In order to address this issue a study used the second harmonic of the Nd:YAG laser at 532 nm. It was show that it is also possible perform LIBS on carious lesion using the Nd:YAG at 532 nm. However, there is not a work direct comparing the LIBS at 532 nm and 1064 nm for carious lesion detection. So, the aim of this work was to investigate the influence of laser wavelength on the LIBS performance for carious lesion detection. In both cases the carious lesion was detected with the advantage of no interference with hydroxyapatite at 532 nm.

  3. Short-pulse propagation in fiber optical parametric amplifiers

    DEFF Research Database (Denmark)

    Cristofori, Valentina

    Fiber optical parametric amplifiers (FOPAs) are attractive because they can provide large gain over a broad range of central wavelengths, depending only on the availability of a suitable pump laser. In addition, FOPAs are suitable for the realization of all-optical signal processing functionalities...... transfer can be reduced in saturated F OPAs. In order to characterize propagation impairments such as dispersion and Kerr effect, affecting signals reaching multi-terabit per second per channel, short pulses on the order of 500 fs need to be considered. Therefore, a short pulses fiber laser source...... is implemented to obtain an all-fiber system. The advantages of all fiber-systems are related to their reliability, long-term stability and compactness. Fiber optical parametric chirped pulse amplification is promising for the amplification of such signals thanks to the inherent compatibility of FOPAs with fiber...

  4. Automation of radioimmunoassay

    International Nuclear Information System (INIS)

    Yamaguchi, Chisato; Yamada, Hideo; Iio, Masahiro

    1974-01-01

    Automation systems for measuring Australian antigen by radioimmunoassay under development were discussed. Samples were processed as follows: blood serum being dispensed by automated sampler to the test tube, and then incubated under controlled time and temperature; first counting being omitted; labelled antibody being dispensed to the serum after washing; samples being incubated and then centrifuged; radioactivities in the precipitate being counted by auto-well counter; measurements being tabulated by automated typewriter. Not only well-type counter but also position counter was studied. (Kanao, N.)

  5. 77 FR 48527 - National Customs Automation Program (NCAP) Test Concerning Automated Commercial Environment (ACE...

    Science.gov (United States)

    2012-08-14

    ... National Customs Automation Program (NCAP) test concerning the simplified entry functionality in the... DEPARTMENT OF HOMELAND SECURITY U.S. Customs and Border Protection National Customs Automation Program (NCAP) Test Concerning Automated Commercial Environment (ACE) Simplified Entry: Modification of...

  6. MoS2-wrapped microfiber-based multi-wavelength soliton fiber laser

    Science.gov (United States)

    Lu, Feifei

    2017-11-01

    The single-, dual- and triple-wavelength passively mode-locked erbium-doped fiber lasers are demonstrated with MoS2 and polarization-dependent isolator (PD-ISO). The saturable absorber is fabricated by wrapping an MoS2 around a microfiber. The intracavity PD-ISO acts as a wavelength-tunable filter with a polarization controller (PC) by adjusting the linear birefringence. Single-wavelength mode-locked fiber laser can self-start with suitable pump power. With appropriate PC state, dual- and triple-wavelength operations can be observed when gains at different wavelengths reach a balance. It is noteworthy that dual-wavelength pulses exhibiting peak and dip sidebands, respectively, are demonstrated in the experiment. The proposed simple and multi-wavelength all-fiber conventional soliton lasers could possess potential applications in numerous fields, such as sensors, THz generations and optical communications.

  7. Laboratory Automation and Middleware.

    Science.gov (United States)

    Riben, Michael

    2015-06-01

    The practice of surgical pathology is under constant pressure to deliver the highest quality of service, reduce errors, increase throughput, and decrease turnaround time while at the same time dealing with an aging workforce, increasing financial constraints, and economic uncertainty. Although not able to implement total laboratory automation, great progress continues to be made in workstation automation in all areas of the pathology laboratory. This report highlights the benefits and challenges of pathology automation, reviews middleware and its use to facilitate automation, and reviews the progress so far in the anatomic pathology laboratory. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Managing laboratory automation.

    Science.gov (United States)

    Saboe, T J

    1995-01-01

    This paper discusses the process of managing automated systems through their life cycles within the quality-control (QC) laboratory environment. The focus is on the process of directing and managing the evolving automation of a laboratory; system examples are given. The author shows how both task and data systems have evolved, and how they interrelate. A BIG picture, or continuum view, is presented and some of the reasons for success or failure of the various examples cited are explored. Finally, some comments on future automation need are discussed.

  9. Determination of the Optimized Automation Rate considering Effects of Automation on Human Operators in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Lee, Seung Min; Seong, Poong Hyun; Kim, Jong Hyun; Kim, Man Cheol

    2015-01-01

    Automation refers to the use of a device or a system to perform a function previously performed by a human operator. It is introduced to reduce the human errors and to enhance the performance in various industrial fields, including the nuclear industry. However, these positive effects are not always achieved in complex systems such as nuclear power plants (NPPs). An excessive introduction of automation can generate new roles for human operators and change activities in unexpected ways. As more automation systems are accepted, the ability of human operators to detect automation failures and resume manual control is diminished. This disadvantage of automation is called the Out-of-the- Loop (OOTL) problem. We should consider the positive and negative effects of automation at the same time to determine the appropriate level of the introduction of automation. Thus, in this paper, we suggest an estimation method to consider the positive and negative effects of automation at the same time to determine the appropriate introduction of automation. This concept is limited in that it does not consider the effects of automation on human operators. Thus, a new estimation method for automation rate was suggested to overcome this problem

  10. Short-term Responses of Posidonia australis to Changes in Light Quality

    Directory of Open Access Journals (Sweden)

    Simone Strydom

    2018-01-01

    Full Text Available Seagrass meadows are highly productive ecosystems that provide ecosystem services to the coastal zone but are declining globally, particularly due to anthropogenic activities that reduce the quantity of light reaching seagrasses, such as dredging, river discharge and eutrophication. Light quality (the spectral composition of the light is also altered by these anthropogenic stressors as the differential attenuation of wavelengths of light is caused by materials within the water column. This study addressed the effect of altered light quality on different life-history stages of the seagrass Posidonia australis, a persistent, habitat-forming species in Australia. Aquarium-based experiments were conducted to determine how adult shoots and seedlings respond to blue (peak λ = 451 nm; green (peak λ = 522 nm; yellow (peak λ = 596 nm and red (peak λ = 673 nm wavelengths with a control of full-spectrum light (λ = 400 – 700 nm, at 200 μmol photons m-2 s-1. Posidonia australis adults did not respond to changes in light quality relative to full-spectrum light, demonstrating a capacity to obtain enough photons from a range of wavelengths across the visible spectrum to maintain short-term growth at high irradiances. Posidonia australis seedlings (<4 months old grown in blue light showed a significant increase in xanthophyll concentrations when compared to plants grown in full-spectrum, demonstrating a pigment acclimation response to blue light. These results differed significantly from negative responses to changes in light quality recently described for Halophila ovalis, a colonizing seagrass species. Persistent seagrasses such as P. australis, appear to be better at tolerating short-term changes in light quality compared to colonizing species when sufficient PPFD is present.

  11. Evaluation of Two Systems for Fundus-Controlled Scotopic and Mesopic Perimetry in Eye with Age-Related Macular Degeneration.

    Science.gov (United States)

    Steinberg, Julia S; Saßmannshausen, Marlene; Pfau, Maximilian; Fleckenstein, Monika; Finger, Robert P; Holz, Frank G; Schmitz-Valckenberg, Steffen

    2017-07-01

    The purpose of this study was to evaluate and compare the MP-1S (Nidek Technologies, Padova, Italy) and the S-MAIA (CenterVue, Padova, Italy) for mesopic and scotopic fundus-controlled perimetry (FCP) in age-related macular degeneration (AMD). Eleven eyes from 11 patients underwent mesopic and, after 30 minutes of dark adaptation, scotopic (MP-1S: Goldmann V, 200 ms, background luminance 0.0032 cd/m 2 ; S-MAIA: Goldman III, 200 ms, background luminance grid of 56 stimulus points covering 16° of the central macula was used. Examination time, fixation stability, and threshold values were analyzed. The upper end of the dynamic range (≤4 dB of lowest threshold) was frequently reached by the MP-1S for mesopic testing (median 34 of 56 stimuli), while threshold values within the lower 4 dB of the dynamic range were occasionally found with the S-MAIA for scotopic testing (median 3 for cyan, median 2 for red). After correction of the stimulus intensity for the S-MAIA results, the median difference for all stimuli between both devices for mesopic testing was -2.0 dB (interquartile range [-4;0], range -14 to 6). The results indicate that robust testing of mesopic and scotopic function is feasible with both devices in patients with AMD, although both devices are susceptible to floor and ceiling effects. The interpretation and particularly the comparison of both scotopic and mesopic FCP results between the MP-1S and the S-MAIA in AMD eyes need to consider variable susceptibility of floor and ceiling effects. Further software updates are desirable as FCP captures visual functional loss that is not noted with best-corrected central visual acuity and is important for clinical trials in AMD.

  12. 78 FR 44142 - Modification of Two National Customs Automation Program (NCAP) Tests Concerning Automated...

    Science.gov (United States)

    2013-07-23

    ... Customs Automation Program (NCAP) Tests Concerning Automated Commercial Environment (ACE) Document Image... (CBP's) plan to modify the National Customs Automation Program (NCAP) tests concerning document imaging... entry process by reducing the number of data elements required to obtain release for cargo transported...

  13. The Science of Home Automation

    Science.gov (United States)

    Thomas, Brian Louis

    Smart home technologies and the concept of home automation have become more popular in recent years. This popularity has been accompanied by social acceptance of passive sensors installed throughout the home. The subsequent increase in smart homes facilitates the creation of home automation strategies. We believe that home automation strategies can be generated intelligently by utilizing smart home sensors and activity learning. In this dissertation, we hypothesize that home automation can benefit from activity awareness. To test this, we develop our activity-aware smart automation system, CARL (CASAS Activity-aware Resource Learning). CARL learns the associations between activities and device usage from historical data and utilizes the activity-aware capabilities to control the devices. To help validate CARL we deploy and test three different versions of the automation system in a real-world smart environment. To provide a foundation of activity learning, we integrate existing activity recognition and activity forecasting into CARL home automation. We also explore two alternatives to using human-labeled data to train the activity learning models. The first unsupervised method is Activity Detection, and the second is a modified DBSCAN algorithm that utilizes Dynamic Time Warping (DTW) as a distance metric. We compare the performance of activity learning with human-defined labels and with automatically-discovered activity categories. To provide evidence in support of our hypothesis, we evaluate CARL automation in a smart home testbed. Our results indicate that home automation can be boosted through activity awareness. We also find that the resulting automation has a high degree of usability and comfort for the smart home resident.

  14. Adaptive Automation Design and Implementation

    Science.gov (United States)

    2015-09-17

    with an automated system to a real-world adaptive au- tomation system implementation. There have been plenty of adaptive automation 17 Adaptive...of systems without increasing manpower requirements by allocating routine tasks to automated aids, improving safety through the use of au- tomated ...between intermediate levels of au- tomation , explicitly defining which human task a given level automates. Each model aids the creation and classification

  15. High-throughput automated system for statistical biosensing employing microcantilevers arrays

    DEFF Research Database (Denmark)

    Bosco, Filippo; Chen, Ching H.; Hwu, En T.

    2011-01-01

    In this paper we present a completely new and fully automated system for parallel microcantilever-based biosensing. Our platform is able to monitor simultaneously the change of resonance frequency (dynamic mode), of deflection (static mode), and of surface roughness of hundreds of cantilevers...... in a very short time over multiple biochemical reactions. We have proven that our system is capable to measure 900 independent microsensors in less than a second. Here, we report statistical biosensing results performed over a haptens-antibody assay, where complete characterization of the biochemical...

  16. Layered distributed architecture for plant automation

    International Nuclear Information System (INIS)

    Aravamuthan, G.; Verma, Yachika; Ranjan, Jyoti; Chachondia, Alka S.; Ganesh, G.

    2005-01-01

    The development of plant automation system and associated software remains one of the greatest challenges to the widespread implementation of highly adaptive re-configurable automation technology. This paper presents a layered distributed architecture for a plant automation system designed to support rapid reconfiguration and redeployment of automation components. The paper first presents evolution of automation architecture and their associated environment in the past few decades and then presents the concept of layered system architecture and the use of automation components to support the construction of a wide variety of automation system. It also highlights the role of standards and technology, which can be used in the development of automation components. We have attempted to adhere to open standards and technology for the development of automation component at a various layers. It also highlights the application of this concept in the development of an Operator Information System (OIS) for Advanced Heavy Water Reactor (AHWR). (author)

  17. Semantics-based Automated Web Testing

    Directory of Open Access Journals (Sweden)

    Hai-Feng Guo

    2015-08-01

    Full Text Available We present TAO, a software testing tool performing automated test and oracle generation based on a semantic approach. TAO entangles grammar-based test generation with automated semantics evaluation using a denotational semantics framework. We show how TAO can be incorporated with the Selenium automation tool for automated web testing, and how TAO can be further extended to support automated delta debugging, where a failing web test script can be systematically reduced based on grammar-directed strategies. A real-life parking website is adopted throughout the paper to demonstrate the effectivity of our semantics-based web testing approach.

  18. Automation in organizations: Eternal conflict

    Science.gov (United States)

    Dieterly, D. L.

    1981-01-01

    Some ideas on and insights into the problems associated with automation in organizations are presented with emphasis on the concept of automation, its relationship to the individual, and its impact on system performance. An analogy is drawn, based on an American folk hero, to emphasize the extent of the problems encountered when dealing with automation within an organization. A model is proposed to focus attention on a set of appropriate dimensions. The function allocation process becomes a prominent aspect of the model. The current state of automation research is mentioned in relation to the ideas introduced. Proposed directions for an improved understanding of automation's effect on the individual's efficiency are discussed. The importance of understanding the individual's perception of the system in terms of the degree of automation is highlighted.

  19. Automated oil spill detection with multispectral imagery

    Science.gov (United States)

    Bradford, Brian N.; Sanchez-Reyes, Pedro J.

    2011-06-01

    In this publication we present an automated detection method for ocean surface oil, like that which existed in the Gulf of Mexico as a result of the April 20, 2010 Deepwater Horizon drilling rig explosion. Regions of surface oil in airborne imagery are isolated using red, green, and blue bands from multispectral data sets. The oil shape isolation procedure involves a series of image processing functions to draw out the visual phenomenological features of the surface oil. These functions include selective color band combinations, contrast enhancement and histogram warping. An image segmentation process then separates out contiguous regions of oil to provide a raster mask to an analyst. We automate the detection algorithm to allow large volumes of data to be processed in a short time period, which can provide timely oil coverage statistics to response crews. Geo-referenced and mosaicked data sets enable the largest identified oil regions to be mapped to exact geographic coordinates. In our simulation, multispectral imagery came from multiple sources including first-hand data collected from the Gulf. Results of the simulation show the oil spill coverage area as a raster mask, along with histogram statistics of the oil pixels. A rough square footage estimate of the coverage is reported if the image ground sample distance is available.

  20. Spectral filter for splitting a beam with electromagnetic radiation having wavelengths in the extreme ultraviolet (EUV) or soft X-Ray (Soft X) and the infrared (IR) wavelength range

    NARCIS (Netherlands)

    van Goor, F.A.; Bijkerk, Frederik; van den Boogaard, Toine; van den Boogaard, A.J.R.; van der Meer, R.

    2012-01-01

    Spectral filter for splitting the primary radiation from a generated beam with primary electromagnetic radiation having a wavelength in the extreme ultraviolet (EUV radiation) or soft X-ray (soft X) wavelength range and parasitic radiation having a wavelength in the infrared wavelength range (IR

  1. Mobile home automation-merging mobile value added services and home automation technologies

    OpenAIRE

    Rosendahl, Andreas; Hampe, Felix J.; Botterweck, Goetz

    2007-01-01

    non-peer-reviewed In this paper we study mobile home automation, a field that emerges from an integration of mobile application platforms and home automation technologies. In a conceptual introduction we first illustrate the need for such applications by introducing a two-dimensional conceptual model of mobility. Subsequently we suggest an architecture and discuss different options of how a user might access a mobile home automation service and the controlled devices. As another contrib...

  2. The wavelength dependence of polarization in NGC 2023

    International Nuclear Information System (INIS)

    Rolph, C. D.; Scarrott, S. M.

    1989-01-01

    NGC 2023 is a bright reflection nebula illuminated by the central star HD37903. At 2 microns the nebula is seen solely by reflected light from the central star but in the NIR there is excess radiation that is supposed to arise from thermal emission from a population of small grains (Sellgren, 1984). The unexpectedly high surface brightness at R and I wavelengths has led to the suggestion that even at these wavelengths there is a significant contribution from this thermal emission process (Witt, Schild, and Kraiman, 1984). If the nebula is seen by reflected starlight then this radiation will be linearly polarized. The level of polarization depends on the scattering geometry, grain size distribution, etc., and is typically 20 to 40 percent for nebulae such as NGC 1999 which is morphologically similar to NGC 2023. If, in any waveband, there is a contribution of radiation from emission processes this radiation will be unpolarized and will serve to dilute the scattered radiation to give a lower level of observed polarization. A study of the wavelength dependence of polarization in nebulae in which there may be thermal emission from grains will indicate the contribution from this process to the total luminosity. Polarization maps were produced in BVRI wavebands for the NGC 2023 nebulosity which confirm that at all wavelengths it is a reflection nebula illuminated by a central star. The wavelength dependence of polarization at representative points in the nebula and in a scatter plot of polarization in V and I wavebands at all points at which measurements are given. Results indicate that throughout the nebula there is a general trend for the level of polarization to increase with wavelength and that maximum levels of polarization occur at the longest wavelengths. No evidence is seen in the data for any significant contribution from the thermal emission from grains in the BVRI luminosity of NGC 2023

  3. Automated contour detection in cardiac MRI using active appearance models: the effect of the composition of the training set

    NARCIS (Netherlands)

    Angelié, Emmanuelle; Oost, Elco R.; Hendriksen, Dennis; Lelieveldt, Boudewijn P. F.; van der Geest, Rob J.; Reiber, Johan H. C.

    2007-01-01

    Definition of the optimal training set for the automated segmentation of short-axis left ventricular magnetic resonance (MR) imaging studies in clinical practice based on active appearance model (AAM). We investigated the segmentation accuracy by varying the size and composition of the training set

  4. Experience of automation failures in training: effects on trust, automation bias, complacency and performance.

    Science.gov (United States)

    Sauer, Juergen; Chavaillaz, Alain; Wastell, David

    2016-06-01

    This work examined the effects of operators' exposure to various types of automation failures in training. Forty-five participants were trained for 3.5 h on a simulated process control environment. During training, participants either experienced a fully reliable, automatic fault repair facility (i.e. faults detected and correctly diagnosed), a misdiagnosis-prone one (i.e. faults detected but not correctly diagnosed) or a miss-prone one (i.e. faults not detected). One week after training, participants were tested for 3 h, experiencing two types of automation failures (misdiagnosis, miss). The results showed that automation bias was very high when operators trained on miss-prone automation encountered a failure of the diagnostic system. Operator errors resulting from automation bias were much higher when automation misdiagnosed a fault than when it missed one. Differences in trust levels that were instilled by the different training experiences disappeared during the testing session. Practitioner Summary: The experience of automation failures during training has some consequences. A greater potential for operator errors may be expected when an automatic system failed to diagnose a fault than when it failed to detect one.

  5. Long wavelength scintillators for fiber-optic applications

    International Nuclear Information System (INIS)

    Lyons, P.B.; Franks, L.; Lutz, S.; Flournoy, J.; Fullman, E.

    1980-01-01

    The use of fiber optics in plasma diagnostics has spurred the development of long wavelength scintillators with fast temporal characteristics. In this paper we describe several new liquid scintillator systems with fluorescent emissions maxima up to 730 nm. Subnanosecond scintillator FWHM response times have been obtained by the operation of liquid scintillators at elevated temperatures. Data on fiber system sensitivity versus fiber length and scintillator emission wavelength will be presented

  6. Future Trends in Process Automation

    OpenAIRE

    Jämsä-Jounela, Sirkka-Liisa

    2007-01-01

    The importance of automation in the process industries has increased dramatically in recent years. In the highly industrialized countries, process automation serves to enhance product quality, master the whole range of products, improve process safety and plant availability, efficiently utilize resources and lower emissions. In the rapidly developing countries, mass production is the main motivation for applying process automation. The greatest demand for process automation is in the chemical...

  7. Automation in Warehouse Development

    CERN Document Server

    Verriet, Jacques

    2012-01-01

    The warehouses of the future will come in a variety of forms, but with a few common ingredients. Firstly, human operational handling of items in warehouses is increasingly being replaced by automated item handling. Extended warehouse automation counteracts the scarcity of human operators and supports the quality of picking processes. Secondly, the development of models to simulate and analyse warehouse designs and their components facilitates the challenging task of developing warehouses that take into account each customer’s individual requirements and logistic processes. Automation in Warehouse Development addresses both types of automation from the innovative perspective of applied science. In particular, it describes the outcomes of the Falcon project, a joint endeavour by a consortium of industrial and academic partners. The results include a model-based approach to automate warehouse control design, analysis models for warehouse design, concepts for robotic item handling and computer vision, and auton...

  8. SPLASH-SXDF Multi-wavelength Photometric Catalog

    Science.gov (United States)

    Mehta, Vihang; Scarlata, Claudia; Capak, Peter; Davidzon, Iary; Faisst, Andreas; Hsieh, Bau Ching; Ilbert, Olivier; Jarvis, Matt; Laigle, Clotilde; Phillips, John; Silverman, John; Strauss, Michael A.; Tanaka, Masayuki; Bowler, Rebecca; Coupon, Jean; Foucaud, Sébastien; Hemmati, Shoubaneh; Masters, Daniel; McCracken, Henry Joy; Mobasher, Bahram; Ouchi, Masami; Shibuya, Takatoshi; Wang, Wei-Hao

    2018-04-01

    We present a multi-wavelength catalog in the Subaru/XMM-Newton Deep Field (SXDF) as part of the Spitzer Large Area Survey with Hyper-Suprime-Cam (SPLASH). We include the newly acquired optical data from the Hyper-Suprime-Cam Subaru Strategic Program, accompanied by IRAC coverage from the SPLASH survey. All available optical and near-infrared data is homogenized and resampled on a common astrometric reference frame. Source detection is done using a multi-wavelength detection image including the u-band to recover the bluest objects. We measure multi-wavelength photometry and compute photometric redshifts as well as physical properties for ∼1.17 million objects over ∼4.2 deg2, with ∼800,000 objects in the 2.4 deg2 HSC-Ultra-Deep coverage. Using the available spectroscopic redshifts from various surveys over the range of 0 fraction of 3.2%. The SPLASH-SXDF catalog is a valuable, publicly available resource, perfectly suited for studying galaxies in the early universe and tracing their evolution through cosmic time.

  9. Experimental determination of the slow-neutron wavelength distribution

    DEFF Research Database (Denmark)

    Lebech, Bente; Mikke, K.; Sledziewska-Blocka, D.

    1970-01-01

    Different experiments for determining the slow-neutron wavelength distribution in the region 227-3 meV have been carried out, and the results compared. It is concluded that the slow-neutron wave-length distribution can be determined accurately by elastic scattering on a pure incoherent or a pure...

  10. 76 FR 34246 - Automated Commercial Environment (ACE); Announcement of National Customs Automation Program Test...

    Science.gov (United States)

    2011-06-13

    ... Environment (ACE); Announcement of National Customs Automation Program Test of Automated Procedures for In... Customs Automation Program (NCAP) test relating to highway movements of commercial goods that are transported in-bond through the United States from one point in Canada to another point in Canada. The NCAP...

  11. Automated cloning methods.; TOPICAL

    International Nuclear Information System (INIS)

    Collart, F.

    2001-01-01

    Argonne has developed a series of automated protocols to generate bacterial expression clones by using a robotic system designed to be used in procedures associated with molecular biology. The system provides plate storage, temperature control from 4 to 37 C at various locations, and Biomek and Multimek pipetting stations. The automated system consists of a robot that transports sources from the active station on the automation system. Protocols for the automated generation of bacterial expression clones can be grouped into three categories (Figure 1). Fragment generation protocols are initiated on day one of the expression cloning procedure and encompass those protocols involved in generating purified coding region (PCR)

  12. Multi-wavelength lasers using AWGs

    NARCIS (Netherlands)

    Besten, den J.H.

    2003-01-01

    Multiwavelength lasers using AWGs can be used as digitally tunable lasers with simple channel selection, and for generating multiple wavelengths simultanously. In this paper a number of different configurations is reviewed.

  13. Driving performance at lateral system limits during partially automated driving.

    Science.gov (United States)

    Naujoks, Frederik; Purucker, Christian; Wiedemann, Katharina; Neukum, Alexandra; Wolter, Stefan; Steiger, Reid

    2017-11-01

    This study investigated driver performance during system limits of partially automated driving. Using a motion-based driving simulator, drivers encountered different situations in which a partially automated vehicle could no longer safely keep the lateral guidance. Drivers were distracted by a non-driving related task on a touch display or driving without an additional secondary task. While driving in partially automated mode drivers could either take their hands off the steering wheel for only a short period of time (10s, so-called 'Hands-on' variant) or for an extended period of time (120s, so-called 'Hands-off' variant). When the system limit was reached (e.g., when entering a work zone with temporary lines), the lateral vehicle control by the automation was suddenly discontinued and a take-over request was issued to the drivers. Regardless of the hands-off interval and the availability of a secondary task, all drivers managed the transition to manual driving safely. No lane exceedances were observed and the situations were rated as 'harmless' by the drivers. The lack of difference between the hands-off intervals can be partly attributed to the fact that most of the drivers kept contact to the steering wheel, even in the hands-off condition. Although all drivers were able to control the system limits, most of them could not explain why exactly the take-over request was issued. The average helpfulness of the take-over request was rated on an intermediate level. Consequently, providing drivers with information about the reason for a system limit can be recommended. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Wavelength dependence of the bidirectional reflectance distribution function (BRDF) of beach sands.

    Science.gov (United States)

    Doctor, Katarina Z; Bachmann, Charles M; Gray, Deric J; Montes, Marcos J; Fusina, Robert A

    2015-11-01

    The wavelength dependence of the dominant directional reflective properties of beach sands was demonstrated using principal component analysis and the related correlation matrix. In general, we found that the hyperspectral bidirectional reflectance distribution function (BRDF) of beach sands has weak wavelength dependence. Its BRDF varies slightly in three broad wavelength regions. The variations are more evident in surfaces of greater visual roughness than in smooth surfaces. The weak wavelength dependence of the BRDF of beach sand can be captured using three broad wavelength regions instead of hundreds of individual wavelengths.

  15. An ultra-wideband tunable multi-wavelength Brillouin fibre laser based on a semiconductor optical amplifier and dispersion compensating fibre in a linear cavity configuration

    International Nuclear Information System (INIS)

    Zulkifli, M Z; Ahmad, H; Hassan, N A; Jemangin, M H; Harun, S W

    2011-01-01

    A multi-wavelength Brillouin fibre laser (MBFL) with an ultra-wideband tuning range from 1420 nm to 1620 nm is demonstrated. The MBFL uses an ultra-wideband semiconductor optical amplifier (SOA) and a dispersion compensating fibre (DCF) as the linear gain medium and nonlinear gain medium, respectively. The proposed MBFL has a wide tuning range covering the short (S-), conventional (C-) and long (L-) bands with a wavelength spacing of 0.08 nm, making it highly suitable for DWDM system applications. The output power of the observed Brillouin Stokes ranges approximately from -5.94 dBm to -0.41 dBm for the S-band, from -4.34 dBm to 0.02 dBm for the C-band and from -2.19 dBm to 0.39 dBm for the L-band. The spacing between each adjacent wavelengths of all the three bands is about 0.08 nm, which is approximately 10.7 GHz for the frequency domain. (lasers)

  16. Semi-automated high-efficiency reflectivity chamber for vacuum UV measurements

    Science.gov (United States)

    Wiley, James; Fleming, Brian; Renninger, Nicholas; Egan, Arika

    2017-08-01

    This paper presents the design and theory of operation for a semi-automated reflectivity chamber for ultraviolet optimized optics. A graphical user interface designed in LabVIEW controls the stages, interfaces with the detector system, takes semi-autonomous measurements, and monitors the system in case of error. Samples and an optical photodiode sit on an optics plate mounted to a rotation stage in the middle of the vacuum chamber. The optics plate rotates the samples and diode between an incident and reflected position to measure the absolute reflectivity of the samples at wavelengths limited by the monochromator operational bandpass of 70 nm to 550 nm. A collimating parabolic mirror on a fine steering tip-tilt motor enables beam steering for detector peak-ups. This chamber is designed to take measurements rapidly and with minimal oversight, increasing lab efficiency for high cadence and high accuracy vacuum UV reflectivity measurements.

  17. Automation, Performance and International Competition

    DEFF Research Database (Denmark)

    Kromann, Lene; Sørensen, Anders

    This paper presents new evidence on trade‐induced automation in manufacturing firms using unique data combining a retrospective survey that we have assembled with register data for 2005‐2010. In particular, we establish a causal effect where firms that have specialized in product types for which...... the Chinese exports to the world market has risen sharply invest more in automated capital compared to firms that have specialized in other product types. We also study the relationship between automation and firm performance and find that firms with high increases in scale and scope of automation have faster...... productivity growth than other firms. Moreover, automation improves the efficiency of all stages of the production process by reducing setup time, run time, and inspection time and increasing uptime and quantity produced per worker. The efficiency improvement varies by type of automation....

  18. Precision measurement of refractive index of air based on laser synthetic wavelength interferometry with Edlén equation estimation.

    Science.gov (United States)

    Yan, Liping; Chen, Benyong; Zhang, Enzheng; Zhang, Shihua; Yang, Ye

    2015-08-01

    A novel method for the precision measurement of refractive index of air (n(air)) based on the combining of the laser synthetic wavelength interferometry with the Edlén equation estimation is proposed. First, a n(air_e) is calculated from the modified Edlén equation according to environmental parameters measured by low precision sensors with an uncertainty of 10(-6). Second, a unique integral fringe number N corresponding to n(air) is determined based on the calculated n(air_e). Then, a fractional fringe ε corresponding to n(air) with high accuracy can be obtained according to the principle of fringe subdivision of laser synthetic wavelength interferometry. Finally, high accurate measurement of n(air) is achieved according to the determined fringes N and ε. The merit of the proposed method is that it not only solves the problem of the measurement accuracy of n(air) being limited by the accuracies of environmental sensors, but also avoids adopting complicated vacuum pumping to measure the integral fringe N in the method of conventional laser interferometry. To verify the feasibility of the proposed method, comparison experiments with Edlén equations in short time and in long time were performed. Experimental results show that the measurement accuracy of n(air) is better than 2.5 × 10(-8) in short time tests and 6.2 × 10(-8) in long time tests.

  19. Wavelength calibration of an imaging spectrometer based on Savart interferometer

    Science.gov (United States)

    Li, Qiwei; Zhang, Chunmin; Yan, Tingyu; Quan, Naicheng; Wei, Yutong; Tong, Cuncun

    2017-09-01

    The basic principle of Fourier-transform imaging spectrometer (FTIS) based on Savart interferometer is outlined. The un-identical distribution of the optical path difference which leads to the wavelength drift of each row of the interferogram is analyzed. Two typical methods for wavelength calibration of the presented system are described. The first method unifies different spectral intervals and maximum spectral frequencies of each row by a reference monochromatic light with known wavelength, and the dispersion compensation of Savart interferometer is also involved. The second approach is based on the least square fitting which builds the functional relation between recovered wavelength, row number and calibrated wavelength by concise equations. The effectiveness of the two methods is experimentally demonstrated with monochromatic lights and mixed light source across the detecting band of the system, and the results indicate that the first method has higher precision and the mean root-mean-square error of the recovered wavelengths is significantly reduced from 19.896 nm to 1.353 nm, while the second method is more convenient to implement and also has good precision of 2.709 nm.

  20. Systematic review automation technologies

    Science.gov (United States)

    2014-01-01

    Systematic reviews, a cornerstone of evidence-based medicine, are not produced quickly enough to support clinical practice. The cost of production, availability of the requisite expertise and timeliness are often quoted as major contributors for the delay. This detailed survey of the state of the art of information systems designed to support or automate individual tasks in the systematic review, and in particular systematic reviews of randomized controlled clinical trials, reveals trends that see the convergence of several parallel research projects. We surveyed literature describing informatics systems that support or automate the processes of systematic review or each of the tasks of the systematic review. Several projects focus on automating, simplifying and/or streamlining specific tasks of the systematic review. Some tasks are already fully automated while others are still largely manual. In this review, we describe each task and the effect that its automation would have on the entire systematic review process, summarize the existing information system support for each task, and highlight where further research is needed for realizing automation for the task. Integration of the systems that automate systematic review tasks may lead to a revised systematic review workflow. We envisage the optimized workflow will lead to system in which each systematic review is described as a computer program that automatically retrieves relevant trials, appraises them, extracts and synthesizes data, evaluates the risk of bias, performs meta-analysis calculations, and produces a report in real time. PMID:25005128

  1. Frequency domain phase retrieval of simultaneous multi-wavelength phase-shifting interferometry

    International Nuclear Information System (INIS)

    Yin, Zhenxing; Zhong, Liyun; Xu, Xiaofei; Zhang, Wangping; Lu, Xiaoxu; Tian, Jindong

    2016-01-01

    In simultaneous multi-wavelength phase-shifting interferometry, we propose a novel frequency domain phase retrieval (FDPR) algorithm. First, using only a one-time phase-shifting operation, a sequence of simultaneous multi-wavelength phase-shifting interferograms (SPSMWIs) are captured by a monochrome charge-coupled device. Second, by performing a Fourier transform for each pixel of SPSMWIs, the wrapped phases of each wavelength can be retrieved from the complex amplitude located in the spectral peak of each wavelength. Finally, the phase of the synthetic wavelength can be obtained by the subtraction between the wrapped phases of a single wavelength. In this study, the principle and the application condition of the proposed approach are discussed. Both the simulation and the experimental result demonstrate the simple and convenient performance of the proposed FDPR approach. (paper)

  2. All-optical short pulse translation through cross-phase modulation in a VO₂ thin film.

    Science.gov (United States)

    Fardad, Shima; Das, Susobhan; Salandrino, Alessandro; Breckenfeld, Eric; Kim, Heungsoo; Wu, Judy; Hui, Rongqing

    2016-01-15

    VO2 is a promising material for reconfigurable photonic devices due to the ultrafast changes in electronic and optical properties associated with its dielectric-to-metal phase transition. Based on a fiber-optic, pump-probe setup at 1550 nm wavelength window, and by varying the pump-pulse duration, we show that the material phase transition is primarily caused by the pump-pulse energy. For the first time, we demonstrate that the instantaneous optical phase modulation of probe during pump leading edge can be utilized to create short optical pulses at probe wavelength, through optical frequency discrimination. This circumvents the impact of long recovery time well known for the phase transition of VO2.

  3. Wavelength-Converter Saving Span Restoration in GMPLS Controlled WDM Optical Networks

    DEFF Research Database (Denmark)

    Ruepp, Sarah Renée; Buron, Jakob Due; Andriolli, N.

    2006-01-01

    We present two label preference schemes to reduce wavelength-conversion during restoration path setup in GMPLS controlled optical networks exploiting span restoration. The amount of required wavelength-conversions can be reduced up to 34 percent.......We present two label preference schemes to reduce wavelength-conversion during restoration path setup in GMPLS controlled optical networks exploiting span restoration. The amount of required wavelength-conversions can be reduced up to 34 percent....

  4. A dual-wavelength tunable laser with superimposed fiber Bragg gratings

    International Nuclear Information System (INIS)

    Álvarez-Tamayo, R I; Durán-Sánchez, M; Pottiez, O; Ibarra-Escamilla, B; Kuzin, E A; Cruz, J L; Andrés, M V

    2013-01-01

    We report a dual-wavelength tunable fiber laser. The cavity is formed by two superimposed fiber Bragg gratings (FBGs) and a temperature tunable high-birefringence fiber optical loop mirror (FOLM). FBGs with wavelengths of 1548.5 and 1538.5 nm were printed in the same section of a fiber using two different masks. The superimposed FBGs were placed on a mechanical mount that allows stretch or compression of the FBGs. As a result of the FBG strain both lines are shifted simultaneously. Dual-wavelength generation requires a fine adjustment of the cavity loss for both wavelengths. (paper)

  5. Absolute analytical prediction of photonic crystal guided mode resonance wavelengths

    DEFF Research Database (Denmark)

    Hermannsson, Pétur Gordon; Vannahme, Christoph; Smith, Cameron

    2014-01-01

    numerically with methods such as rigorous coupled wave analysis. Here it is demonstrated how the absolute resonance wavelengths of such structures can be predicted by analytically modeling them as slab waveguides in which the propagation constant is determined by a phase matching condition. The model...... is experimentally verified to be capable of predicting the absolute resonance wavelengths to an accuracy of within 0.75 nm, as well as resonance wavelength shifts due to changes in cladding index within an accuracy of 0.45 nm across the visible wavelength regime in the case where material dispersion is taken...

  6. The Automation-by-Expertise-by-Training Interaction.

    Science.gov (United States)

    Strauch, Barry

    2017-03-01

    I introduce the automation-by-expertise-by-training interaction in automated systems and discuss its influence on operator performance. Transportation accidents that, across a 30-year interval demonstrated identical automation-related operator errors, suggest a need to reexamine traditional views of automation. I review accident investigation reports, regulator studies, and literature on human computer interaction, expertise, and training and discuss how failing to attend to the interaction of automation, expertise level, and training has enabled operators to commit identical automation-related errors. Automated systems continue to provide capabilities exceeding operators' need for effective system operation and provide interfaces that can hinder, rather than enhance, operator automation-related situation awareness. Because of limitations in time and resources, training programs do not provide operators the expertise needed to effectively operate these automated systems, requiring them to obtain the expertise ad hoc during system operations. As a result, many do not acquire necessary automation-related system expertise. Integrating automation with expected operator expertise levels, and within training programs that provide operators the necessary automation expertise, can reduce opportunities for automation-related operator errors. Research to address the automation-by-expertise-by-training interaction is needed. However, such research must meet challenges inherent to examining realistic sociotechnical system automation features with representative samples of operators, perhaps by using observational and ethnographic research. Research in this domain should improve the integration of design and training and, it is hoped, enhance operator performance.

  7. Distribution automation

    International Nuclear Information System (INIS)

    Gruenemeyer, D.

    1991-01-01

    This paper reports on a Distribution Automation (DA) System enhances the efficiency and productivity of a utility. It also provides intangible benefits such as improved public image and market advantages. A utility should evaluate the benefits and costs of such a system before committing funds. The expenditure for distribution automation is economical when justified by the deferral of a capacity increase, a decrease in peak power demand, or a reduction in O and M requirements

  8. Eighth International Conference on Informatics in Control Automation and Robotics (ICINCO 2011)

    CERN Document Server

    Bernard, Alain; Gusikhin, Oleg; Madani, Kurosh; Informatics in Control, Automation and Robotics

    2013-01-01

    The present book includes a set of selected papers from the eighth "International Conference on Informatics in Control Automation and Robotics" (ICINCO 2011), held in Noordwijkerhout, The Netherlands, from 28 to 31 July 2011. The conference was organized in four simultaneous tracks: "Intelligent Control Systems and Optimization", "Robotics and Automation", "Signal Processing, Sensors, Systems Modeling and Control" and "Industrial Engineering, Production and Management". The book is based on the same structure.   ICINCO received 322 paper submissions, not including those of workshops or special sessions, from 52 countries, in all continents. After a double blind paper review performed by the Program Committee only 33 submissions were accepted as full papers and thus selected for oral presentation, leading to a full paper acceptance ratio of 10%. Additional papers were accepted as short papers and posters. A further refinement was made after the conference, based also on the assessment of presentation quality,...

  9. Understanding human management of automation errors

    Science.gov (United States)

    McBride, Sara E.; Rogers, Wendy A.; Fisk, Arthur D.

    2013-01-01

    Automation has the potential to aid humans with a diverse set of tasks and support overall system performance. Automated systems are not always reliable, and when automation errs, humans must engage in error management, which is the process of detecting, understanding, and correcting errors. However, this process of error management in the context of human-automation interaction is not well understood. Therefore, we conducted a systematic review of the variables that contribute to error management. We examined relevant research in human-automation interaction and human error to identify critical automation, person, task, and emergent variables. We propose a framework for management of automation errors to incorporate and build upon previous models. Further, our analysis highlights variables that may be addressed through design and training to positively influence error management. Additional efforts to understand the error management process will contribute to automation designed and implemented to support safe and effective system performance. PMID:25383042

  10. Design of a Short/Open-Ended Slot Antenna with Capacitive Coupling Feed Strips for Hepta-Band Mobile Application

    Directory of Open Access Journals (Sweden)

    Kyoseung Keum

    2018-01-01

    Full Text Available In this paper, a planar printed hybrid short/open-ended slot antenna with capacitive coupling feed strips is proposed for hepta-band mobile applications. The proposed antenna is comprised of a slotted ground plane on the top plane and two capacitive coupling feed strips with a chip inductor on the bottom plane. At the low frequency band, the short-ended long slot fed by strip 1 generates its half-wavelength resonance mode, whereas the T-shaped open ended slot fed by strip 2 generates its quarter-wavelength resonance mode for the high frequency band. The antenna provides a wide bandwidth covering GSM850/GSM900/DCS/PCS/UMTS/LTE2300/LTE2500 operation bands. Moreover, the antenna occupies a small volume of 15 mm × 50 mm × 1 mm. The operating principle of the proposed antenna and the simulation/measurement results are presented and discussed.

  11. Three wavelength optical alignment of the Nova laser

    International Nuclear Information System (INIS)

    Swift, C.D.; Bliss, E.S.; Jones, W.A.; Seppala, L.G.

    1983-01-01

    The Nova laser, presently under construction at Lawrence Livermore National Laboratory, will be capable of delivering more than 100 kJ of focused energy to an Inertial Confinement Fusion (ICF) target. Operation at the fundamental wavelength of the laser (1.05 μm) and at the second and third harmonic will be possible. This paper will discuss the optical alignment systems and techniques being implemented to align the laser output to the target at these wavelengths prior to each target irradiation. When experiments require conversion of the laser light to wavelengths of 0.53 μm and 0.35 μm prior to target irradiation, this will be accomplished in harmonic conversion crystals located at the beam entrances to the target chamber. The harmonic alignment system will be capable of introducing colinear alignment beams of all three wavelengths into the laser chains at the final spatial filter. The alignment beam at 1.05 μm will be about three cm in diameter and intense enough to align the conversion crystals. Beams at 0.53 μm and 0.35 μm will be expanded by the spatial filter to full aperture (74 cm) and used to illuminate the target and other alignment aids at the target chamber focus. This harmonic illumination system will include viewing capability as well. A final alignment sensor will be located at the target chamber. It will view images of the chamber focal plane at all three wavelengths. In this way, each beam can be aligned at the desired wavelength to produce the focal pattern required for each target irradiation. The design of the major components in the harmonic alignment system will be described, and a typical alignment sequence for alignment to a target will be presented

  12. A new fully automated FTIR system for total column measurements of greenhouse gases

    Science.gov (United States)

    Geibel, M. C.; Gerbig, C.; Feist, D. G.

    2010-10-01

    This article introduces a new fully automated FTIR system that is part of the Total Carbon Column Observing Network (TCCON). It will provide continuous ground-based measurements of column-averaged volume mixing ratio for CO2, CH4 and several other greenhouse gases in the tropics. Housed in a 20-foot shipping container it was developed as a transportable system that could be deployed almost anywhere in the world. We describe the automation concept which relies on three autonomous subsystems and their interaction. Crucial components like a sturdy and reliable solar tracker dome are described in detail. The automation software employs a new approach relying on multiple processes, database logging and web-based remote control. First results of total column measurements at Jena, Germany show that the instrument works well and can provide parts of the diurnal as well as seasonal cycle for CO2. Instrument line shape measurements with an HCl cell suggest that the instrument stays well-aligned over several months. After a short test campaign for side by side intercomaprison with an existing TCCON instrument in Australia, the system will be transported to its final destination Ascension Island.

  13. WIRELESS HOME AUTOMATION SYSTEM BASED ON MICROCONTROLLER

    Directory of Open Access Journals (Sweden)

    MUNA H. SALEH

    2017-11-01

    Full Text Available This paper presents the development of Global System Mobile (GSM-based control home air-conditioner for home automation system. The main aim of the prototype development is to reduce electricity wastage. GSM module was used for receiving Short Message Service (SMS from the user’s mobile phone that automatically enable the controller to take any further action such as to switch ON and OFF the home air-conditioner. The system controls the air-conditioner based on the temperature reading through the sensor. Every period temperature sensor sends the degree to Micro Controller Unit (MCU through ZigBee. Based on temperature degree MCU send ON or OFF signal to switch. Additionally, system allows user to operate or shut down the airconditioner remotely through SMS.

  14. Human-centred automation: an explorative study

    International Nuclear Information System (INIS)

    Hollnagel, Erik; Miberg, Ann Britt

    1999-05-01

    The purpose of the programme activity on human-centred automation at the HRP is to develop knowledge (in the form of models and theories) and tools (in the form of techniques and simulators) to support design of automation that ensures effective human performance and comprehension. This report presents the work done on both the analytical and experimental side of this project. The analytical work has surveyed common definitions of automation and traditional design principles. A general finding is that human-centred automation usually is defined in terms of what it is not. This is partly due to a lack of adequate models and of human-automation interaction. Another result is a clarification of the consequences of automation, in particular with regard to situation awareness and workload. The experimental work has taken place as an explorative experiment in HAMMLAB in collaboration with IPSN (France). The purpose of this experiment was to increase the understanding of how automation influences operator performance in NPP control rooms. Two different types of automation (extensive and limited) were considered in scenarios having two different degrees of complexity (high and low), and involving diagnostic and procedural tasks. Six licensed NPP crews from the NPP at Loviisa, Finland, participated in the experiment. The dependent variables applied were plant performance, operator performance, self-rated crew performance, situation awareness, workload, and operator trust in the automation. The results from the diagnostic scenarios indicated that operators' judgement of crew efficiency was related to their level of trust in the automation, and further that operators trusted automation least and rated crew performance lowest in situations where crew performance was efficient and vice versa. The results from procedural scenarios indicated that extensive automation efficiently supported operators' performance, and further that operator' judgement of crew performance efficiency

  15. Configuration Management Automation (CMA) -

    Data.gov (United States)

    Department of Transportation — Configuration Management Automation (CMA) will provide an automated, integrated enterprise solution to support CM of FAA NAS and Non-NAS assets and investments. CMA...

  16. Toward designing for trust in database automation

    Energy Technology Data Exchange (ETDEWEB)

    Duez, P. P.; Jamieson, G. A. [Cognitive Engineering Laboratory, Univ. of Toronto, 5 King' s College Rd., Toronto, Ont. M5S 3G8 (Canada)

    2006-07-01

    Appropriate reliance on system automation is imperative for safe and productive work, especially in safety-critical systems. It is unsafe to rely on automation beyond its designed use; conversely, it can be both unproductive and unsafe to manually perform tasks that are better relegated to automated tools. Operator trust in automated tools mediates reliance, and trust appears to affect how operators use technology. As automated agents become more complex, the question of trust in automation is increasingly important. In order to achieve proper use of automation, we must engender an appropriate degree of trust that is sensitive to changes in operating functions and context. In this paper, we present research concerning trust in automation in the domain of automated tools for relational databases. Lee and See have provided models of trust in automation. One model developed by Lee and See identifies three key categories of information about the automation that lie along a continuum of attributional abstraction. Purpose-, process-and performance-related information serve, both individually and through inferences between them, to describe automation in such a way as to engender r properly-calibrated trust. Thus, one can look at information from different levels of attributional abstraction as a general requirements analysis for information key to appropriate trust in automation. The model of information necessary to engender appropriate trust in automation [1] is a general one. Although it describes categories of information, it does not provide insight on how to determine the specific information elements required for a given automated tool. We have applied the Abstraction Hierarchy (AH) to this problem in the domain of relational databases. The AH serves as a formal description of the automation at several levels of abstraction, ranging from a very abstract purpose-oriented description to a more concrete description of the resources involved in the automated process

  17. Toward designing for trust in database automation

    International Nuclear Information System (INIS)

    Duez, P. P.; Jamieson, G. A.

    2006-01-01

    Appropriate reliance on system automation is imperative for safe and productive work, especially in safety-critical systems. It is unsafe to rely on automation beyond its designed use; conversely, it can be both unproductive and unsafe to manually perform tasks that are better relegated to automated tools. Operator trust in automated tools mediates reliance, and trust appears to affect how operators use technology. As automated agents become more complex, the question of trust in automation is increasingly important. In order to achieve proper use of automation, we must engender an appropriate degree of trust that is sensitive to changes in operating functions and context. In this paper, we present research concerning trust in automation in the domain of automated tools for relational databases. Lee and See have provided models of trust in automation. One model developed by Lee and See identifies three key categories of information about the automation that lie along a continuum of attributional abstraction. Purpose-, process-and performance-related information serve, both individually and through inferences between them, to describe automation in such a way as to engender r properly-calibrated trust. Thus, one can look at information from different levels of attributional abstraction as a general requirements analysis for information key to appropriate trust in automation. The model of information necessary to engender appropriate trust in automation [1] is a general one. Although it describes categories of information, it does not provide insight on how to determine the specific information elements required for a given automated tool. We have applied the Abstraction Hierarchy (AH) to this problem in the domain of relational databases. The AH serves as a formal description of the automation at several levels of abstraction, ranging from a very abstract purpose-oriented description to a more concrete description of the resources involved in the automated process

  18. Automated electron microprobe

    International Nuclear Information System (INIS)

    Thompson, K.A.; Walker, L.R.

    1986-01-01

    The Plant Laboratory at the Oak Ridge Y-12 Plant has recently obtained a Cameca MBX electron microprobe with a Tracor Northern TN5500 automation system. This allows full stage and spectrometer automation and digital beam control. The capabilities of the system include qualitative and quantitative elemental microanalysis for all elements above and including boron in atomic number, high- and low-magnification imaging and processing, elemental mapping and enhancement, and particle size, shape, and composition analyses. Very low magnification, quantitative elemental mapping using stage control (which is of particular interest) has been accomplished along with automated size, shape, and composition analysis over a large relative area

  19. Short-term scheduling of an open-pit mine with multiple objectives

    Science.gov (United States)

    Blom, Michelle; Pearce, Adrian R.; Stuckey, Peter J.

    2017-05-01

    This article presents a novel algorithm for the generation of multiple short-term production schedules for an open-pit mine, in which several objectives, of varying priority, characterize the quality of each solution. A short-term schedule selects regions of a mine site, known as 'blocks', to be extracted in each week of a planning horizon (typically spanning 13 weeks). Existing tools for constructing these schedules use greedy heuristics, with little optimization. To construct a single schedule in which infrastructure is sufficiently utilized, with production grades consistently close to a desired target, a planner must often run these heuristics many times, adjusting parameters after each iteration. A planner's intuition and experience can evaluate the relative quality and mineability of different schedules in a way that is difficult to automate. Of interest to a short-term planner is the generation of multiple schedules, extracting available ore and waste in varying sequences, which can then be manually compared. This article presents a tool in which multiple, diverse, short-term schedules are constructed, meeting a range of common objectives without the need for iterative parameter adjustment.

  20. Automate functional testing

    Directory of Open Access Journals (Sweden)

    Ramesh Kalindri

    2014-06-01

    Full Text Available Currently, software engineers are increasingly turning to the option of automating functional tests, but not always have successful in this endeavor. Reasons range from low planning until over cost in the process. Some principles that can guide teams in automating these tests are described in this article.