WorldWideScience

Sample records for short time compared

  1. A Unified Framework for Estimating Minimum Detectable Effects for Comparative Short Interrupted Time Series Designs

    Science.gov (United States)

    Price, Cristofer; Unlu, Fatih

    2014-01-01

    The Comparative Short Interrupted Time Series (C-SITS) design is a frequently employed quasi-experimental method, in which the pre- and post-intervention changes observed in the outcome levels of a treatment group is compared with those of a comparison group where the difference between the former and the latter is attributed to the treatment. The…

  2. Decision time horizon for music genre classification using short time features

    DEFF Research Database (Denmark)

    Ahrendt, Peter; Meng, Anders; Larsen, Jan

    2004-01-01

    In this paper music genre classification has been explored with special emphasis on the decision time horizon and ranking of tapped-delay-line short-time features. Late information fusion as e.g. majority voting is compared with techniques of early information fusion such as dynamic PCA (DPCA......). The most frequently suggested features in the literature were employed including mel-frequency cepstral coefficients (MFCC), linear prediction coefficients (LPC), zero-crossing rate (ZCR), and MPEG-7 features. To rank the importance of the short time features consensus sensitivity analysis is applied...

  3. Josephson comparator switching time

    Energy Technology Data Exchange (ETDEWEB)

    Herr, Quentin P; Miller, Donald L; Przybysz, John X [Northrop Grumman, Baltimore, MD (United States)

    2006-05-15

    Comparator performance can be characterized in terms of both sensitivity and decision time. Delta-sigma analogue-to-digital converters are tolerant of sensitivity errors but require short decision time due to feedback. We have analysed the Josephson comparator using the numerical solution of the Fokker-Planck equation, which describes the time evolution of the ensemble probability distribution. At balance, the result is essentially independent of temperature in the range 5-20 K. There is a very small probability, 1 x 10{sup -14}, that the decision time will be longer than seven single-flux-quantum pulse widths, defined as Phi{sub 0}/(I{sub c}R{sub n}). For junctions with a critical current density of 4.5 kA, this decision time is only 20 ps. Decision time error probability decreases rapidly with lengthening time interval, at a rate of two orders of magnitude per pulse width. We conclude that Josephson comparator performance is quite favourable for analogue-to-digital converter applications.

  4. A short-time fading study of Al2O3:C

    International Nuclear Information System (INIS)

    Nascimento, L.F.; Vanhavere, F.; Silva, E.H.; Deene, Y. De

    2015-01-01

    This paper studies the short-time fading from Al 2 O 3 :C by measuring optically stimulated luminescence (OSL) signals (Total OSL: T OSL , and Peak OSL: P OSL ) from droplets and Luxel™ pellets. The influence of various bleaching regimes (blue, green and white) and light power is compared. The fading effect is the decay of the OSL signal in the dark at room temperature. Al 2 O 3 :C detectors were submitted to various bleaching regimes, irradiated with a reference dose and read out after different time spans. Investigations were carried out using 2 mm size droplet detectors, made of thin Al 2 O 3 :C powder mixed with a photocured polymer. Tests were compared to Luxel™-type detectors (Landauer Inc.). Short-time post-irradiation fading is present in OSL results (T OSL and P OSL ) droplets for time spans up to 200 s. The effect of short-time fading can be lowered/removed when treating the detectors with high-power and/or long time bleaching regimes; this result was observed in both T OSL and P OSL from droplets and Luxel™. - Highlights: • Droplet composed of thin powder of Al 2 O 3 :C was prepared using a photo-curable polymer. • Powder grain sizes ranged from 5 μm to 35 μm. • Short-time fading was measured for irradiated samples. • Various bleaching regimes and light power was tested. • Droplets were compared to a commercially dosimeter, Luxel™

  5. Laparoscopic colectomy for transverse colon cancer: comparative analysis of short- and long-term outcomes.

    Science.gov (United States)

    Sheng, Weizheng; Zhang, Bo; Chen, Weifeng; Gu, Dayong; Gao, Weidong

    2015-01-01

    This study evaluated the short- and long-term outcomes of laparoscopic colectomy compared with open colectomy for patients with transverse colon cancer by matched-pair analysis. This study enrolled 59 patients who underwent laparoscopic colectomy and compared them with 59 matched patients who underwent open colectomy for transverse colon cancer. The following parameters were matched: clinical stage and type of resection. Both short- and long-term outcomes of laparoscopic colectomy were compared with those of open colectomy. No difference was observed between the two groups in terms of age, gender, ASA score, comorbidity, clinical stage and operative procedures. Regarding short-term outcomes, blood loss, time to first flatus, time to liquid diet and postoperative stay were significantly shorter in the laparoscopy group than in the open group, while operation time was significantly longer in the laparoscopy group than in the open group. Postoperative complication was similar between the two groups. With respect to long-term outcomes, the two groups did not differ significantly in terms of 5-year overall and disease-free survival. In summary, laparoscopic colectomy is a safe and feasible option for selected patients with transverse colon cancer. The short- and long-term outcomes of laparoscopic colectomy are considered to be acceptable.

  6. Potential barrier classification by short-time measurement

    International Nuclear Information System (INIS)

    Granot, Er'el; Marchewka, Avi

    2006-01-01

    We investigate the short-time dynamics of a delta-function potential barrier on an initially confined wave packet. There are mainly two conclusions: (A) At short times the probability density of the first particles that passed through the barrier is unaffected by it. (B) When the barrier is absorptive (i.e., its potential is imaginary) it affects the transmitted wave function at shorter times than a real potential barrier. Therefore, it is possible to distinguish between an imaginary and a real potential barrier by measuring its effect at short times only on the transmitting wave function

  7. Potential barrier classification by short-time measurement

    Science.gov (United States)

    Granot, Er'El; Marchewka, Avi

    2006-03-01

    We investigate the short-time dynamics of a delta-function potential barrier on an initially confined wave packet. There are mainly two conclusions: (A) At short times the probability density of the first particles that passed through the barrier is unaffected by it. (B) When the barrier is absorptive (i.e., its potential is imaginary) it affects the transmitted wave function at shorter times than a real potential barrier. Therefore, it is possible to distinguish between an imaginary and a real potential barrier by measuring its effect at short times only on the transmitting wave function.

  8. Short-time quantum dynamics of sharp boundaries potentials

    Energy Technology Data Exchange (ETDEWEB)

    Granot, Er' el, E-mail: erel@ariel.ac.il; Marchewka, Avi

    2015-02-15

    Despite the high prevalence of singular potential in general, and rectangular potentials in particular, in applied scattering models, to date little is known about their short time effects. The reason is that singular potentials cause a mixture of complicated local as well as non-local effects. The object of this work is to derive a generic method to calculate analytically the short-time impact of any singular potential. In this paper it is shown that the scattering of a smooth wavefunction on a singular potential is totally equivalent, in the short-time regime, to the free propagation of a singular wavefunction. However, the latter problem was totally addressed analytically in Ref. [7]. Therefore, this equivalency can be utilized in solving analytically the short time dynamics of any smooth wavefunction at the presence of a singular potentials. In particular, with this method the short-time dynamics of any problem where a sharp boundaries potential (e.g., a rectangular barrier) is turned on instantaneously can easily be solved analytically.

  9. Short-time quantum dynamics of sharp boundaries potentials

    Science.gov (United States)

    Granot, Er'el; Marchewka, Avi

    2015-02-01

    Despite the high prevalence of singular potential in general, and rectangular potentials in particular, in applied scattering models, to date little is known about their short time effects. The reason is that singular potentials cause a mixture of complicated local as well as non-local effects. The object of this work is to derive a generic method to calculate analytically the short-time impact of any singular potential. In this paper it is shown that the scattering of a smooth wavefunction on a singular potential is totally equivalent, in the short-time regime, to the free propagation of a singular wavefunction. However, the latter problem was totally addressed analytically in Ref. [7]. Therefore, this equivalency can be utilized in solving analytically the short time dynamics of any smooth wavefunction at the presence of a singular potentials. In particular, with this method the short-time dynamics of any problem where a sharp boundaries potential (e.g., a rectangular barrier) is turned on instantaneously can easily be solved analytically.

  10. Short-time quantum dynamics of sharp boundaries potentials

    International Nuclear Information System (INIS)

    Granot, Er'el; Marchewka, Avi

    2015-01-01

    Despite the high prevalence of singular potential in general, and rectangular potentials in particular, in applied scattering models, to date little is known about their short time effects. The reason is that singular potentials cause a mixture of complicated local as well as non-local effects. The object of this work is to derive a generic method to calculate analytically the short-time impact of any singular potential. In this paper it is shown that the scattering of a smooth wavefunction on a singular potential is totally equivalent, in the short-time regime, to the free propagation of a singular wavefunction. However, the latter problem was totally addressed analytically in Ref. [7]. Therefore, this equivalency can be utilized in solving analytically the short time dynamics of any smooth wavefunction at the presence of a singular potentials. In particular, with this method the short-time dynamics of any problem where a sharp boundaries potential (e.g., a rectangular barrier) is turned on instantaneously can easily be solved analytically

  11. Quality of Standard Reference Materials for Short Time Activation Analysis

    International Nuclear Information System (INIS)

    Ismail, S.S.; Oberleitner, W.

    2003-01-01

    Some environmental reference materials (CFA-1633 b, IAEA-SL-1, SARM-1,BCR-176, Coal-1635, IAEA-SL-3, BCR-146, and SRAM-5) were analysed by short-time activation analysis. The results show that these materials can be classified in three groups, according to their activities after irradiation. The obtained results were compared in order to create a quality index for determination of short-lived nuclides at high count rates. It was found that Cfta is not a suitable standard for determining very short-lived nuclides (half-lives<1 min) because the activity it produces is 15-fold higher than that SL-3. Biological reference materials, such as SRM-1571, SRM-1573, SRM-1575, SRM-1577, IAEA-392, and IAEA-393, were also investigated by a higher counting efficiency system. The quality of this system and its well-type detector for investigating short-lived nuclides was discussed

  12. Short Sleep Times Predict Obesity in Internal Medicine Clinic Patients

    Science.gov (United States)

    Buscemi, Dolores; Kumar, Ashwani; Nugent, Rebecca; Nugent, Kenneth

    2007-01-01

    Study Objectives: Epidemiological studies have demonstrated an association between short sleep times and obesity as defined by body mass index (BMI). We wanted to determine whether this association occurs in patients with chronic medical diagnoses since the number of confounding factors is likely higher in patients than the general population. Methods: Two hundred patients attending internal medicine clinics completed a survey regarding sleep habits, lifestyle characteristics, and medical diagnoses. An independent surveyor collected the information on the questionnaires and reviewed the medical records. Height and weight were measured by clinic personnel. Data were analyzed with multivariate logistic regression. Results: Subjects with short sleep times (< 7 hours) had an increased likelihood of obesity as defined by a BMI ≥ 30 kg/m2 when compared to the reference group of (8, 9] hours (odds ratio 2.93; 95% confidence interval, 1.06–8.09). There was a U-shaped relationship between obesity and sleep time in women but not in men. Young age (18 to 49 years), not smoking, drinking alcohol, hypertension, diabetes, and sleep apnea were also associated with obesity in the overall model. Conclusions: This study demonstrates an association between short sleep times and obesity in undifferentiated patients attending an internal medicine clinic using models adjusting for age, lifestyle characteristics, and some medical diagnoses. The U-shaped relationship in women suggests that sleep patterns may have gender specific associations. These observations provide the background for therapeutic trials in weight loss in patients with established medical problems. Citation: Buscemi D; Kumar A; Nugent R; Nugent K. Short sleep times predict obesity in internal medicine clinic patients. J Clin Sleep Med 2007;3(7):681–688. PMID:18198800

  13. Short-time quantum propagator and Bohmian trajectories

    Science.gov (United States)

    de Gosson, Maurice; Hiley, Basil

    2013-12-01

    We begin by giving correct expressions for the short-time action following the work Makri-Miller. We use these estimates to derive an accurate expression modulo Δt2 for the quantum propagator and we show that the quantum potential is negligible modulo Δt2 for a point source, thus justifying an unfortunately largely ignored observation of Holland made twenty years ago. We finally prove that this implies that the quantum motion is classical for very short times.

  14. Short-time quantum propagator and Bohmian trajectories

    International Nuclear Information System (INIS)

    Gosson, Maurice de; Hiley, Basil

    2013-01-01

    We begin by giving correct expressions for the short-time action following the work Makri–Miller. We use these estimates to derive an accurate expression modulo Δt 2 for the quantum propagator and we show that the quantum potential is negligible modulo Δt 2 for a point source, thus justifying an unfortunately largely ignored observation of Holland made twenty years ago. We finally prove that this implies that the quantum motion is classical for very short times.

  15. Active mode-locking of mid-infrared quantum cascade lasers with short gain recovery time.

    Science.gov (United States)

    Wang, Yongrui; Belyanin, Alexey

    2015-02-23

    We investigate the dynamics of actively modulated mid-infrared quantum cascade lasers (QCLs) using space- and time-domain simulations of coupled density matrix and Maxwell equations with resonant tunneling current taken into account. We show that it is possible to achieve active mode locking and stable generation of picosecond pulses in high performance QCLs with a vertical laser transition and a short gain recovery time by bias modulation of a short section of a monolithic Fabry-Perot cavity. In fact, active mode locking in QCLs with a short gain recovery time turns out to be more robust to the variation of parameters as compared to previously studied lasers with a long gain recovery time. We investigate the effects of spatial hole burning and phase locking on the laser output.

  16. Short-time quantum propagator and Bohmian trajectories

    Energy Technology Data Exchange (ETDEWEB)

    Gosson, Maurice de, E-mail: maurice.degosson@gmail.com [Universität Wien, Fakultät für Mathematik, NuHAG, Wien 1090 (Austria); Hiley, Basil [University of London, Birkbeck College, Theoretical Physics Unit, London WC1E 7HX (United Kingdom)

    2013-12-06

    We begin by giving correct expressions for the short-time action following the work Makri–Miller. We use these estimates to derive an accurate expression modulo Δt{sup 2} for the quantum propagator and we show that the quantum potential is negligible modulo Δt{sup 2} for a point source, thus justifying an unfortunately largely ignored observation of Holland made twenty years ago. We finally prove that this implies that the quantum motion is classical for very short times.

  17. COMPARATIVE ANALYSIS OF TRANSPORT AIRCRAFT, BACKROUND FOR SHORT/ MEDIUM COURIER TRANSPORT AIRCRAFT PROCUREMENT

    Directory of Open Access Journals (Sweden)

    Matei POPA

    2010-03-01

    Full Text Available In accordance with Air Force requirements, the comparative analysis of short/medium transport aircraft comes to sustain procurement decision of short/medium transport aircraft. This paper presents, in short, the principles and the results of the comparative analysis for short/medium military transport aircraft.

  18. Flow characteristics of a pilot-scale high temperature, short time pasteurizer.

    Science.gov (United States)

    Tomasula, P M; Kozempel, M F

    2004-09-01

    In this study, we present a method for determining the fastest moving particle (FMP) and residence time distribution (RTD) in a pilot-scale high temperature, short time (HTST) pasteurizer to ensure that laboratory or pilot-scale HTST apparatus meets the Pasteurized Milk Ordinance standards for pasteurization of milk and can be used for obtaining thermal inactivation data. The overall dimensions of the plate in the pasteurizer were 75 x 115 mm, with a thickness of 0.5 mm and effective diameter of 3.0 mm. The pasteurizer was equipped with nominal 21.5- and 52.2-s hold tubes, and flow capacity was variable from 0 to 20 L/h. Tracer studies were used to determine FMP times and RTD data to establish flow characteristics. Using brine milk as tracer, the FMP time for the short holding section was 18.6 s and for the long holding section was 36 s at 72 degrees C, compared with the nominal times of 21.5 and 52.2 s, respectively. The RTD study indicates that the short hold section was 45% back mixed and 55% plug flow for whole milk at 72 degrees C. The long hold section was 91% plug and 9% back mixed for whole milk at 72 degrees C. This study demonstrates that continuous laboratory and pilot-scale pasteurizers may be used to study inactivation of microorganisms only if the flow conditions in the holding tube are established for comparison with commercial HTST systems.

  19. Improving Music Genre Classification by Short-Time Feature Integration

    DEFF Research Database (Denmark)

    Meng, Anders; Ahrendt, Peter; Larsen, Jan

    2005-01-01

    Many different short-time features, using time windows in the size of 10-30 ms, have been proposed for music segmentation, retrieval and genre classification. However, often the available time frame of the music to make the actual decision or comparison (the decision time horizon) is in the range...... of seconds instead of milliseconds. The problem of making new features on the larger time scale from the short-time features (feature integration) has only received little attention. This paper investigates different methods for feature integration and late information fusion for music genre classification...

  20. Single-Incision Laparoscopic Colectomy for Cancer: Short-Term Outcomes and Comparative Analysis

    Directory of Open Access Journals (Sweden)

    Rodrigo Pedraza

    2013-01-01

    Full Text Available Introduction. Single-incision laparoscopic colectomy (SILC is a viable and safe technique; however, there are no single-institution studies comparing outcomes of SILC for colon cancer with well-established minimally invasive techniques. We evaluated the short-term outcomes following SILC for cancer compared to a group of well-established minimally invasive techniques. Methods. Fifty consecutive patients who underwent SILC for colon cancer were compared to a control group composed of 50 cases of minimally invasive colectomies performed with either conventional multiport or hand-assisted laparoscopic technique. The groups were paired based on the type of procedure. Demographics, intraoperative, and postoperative outcomes were assessed. Results. With the exception of BMI, demographics were similar between both groups. Most of the procedures were right colectomies ( and anterior resections (. There were no significant differences in operative time (127.9 versus 126.7 min, conversions (0 versus 1, complications (14% versus 8%, length of stay (4.5 versus 4.0 days, readmissions (2% versus 2%, and reoperations (2% versus 2%. Oncological outcomes were also similar between groups. Conclusions. SILC is an oncologically sound alternative for the management of colon cancer and results in similar short-term outcomes as compared with well-established minimally invasive techniques.

  1. Short recovery time NMR probe

    International Nuclear Information System (INIS)

    Ramia, M.E.; Martin, C.A.; Jeandrevin, S.

    2011-01-01

    A NMR probe for low frequency and short recovery time is presented in this work. The probe contains the tuning circuit, diode expanders and quarter wavelength networks to protect the receiver from both the amplifier noise and the coil ringing following the transmitter power pulse. It also possesses a coil damper which is activated by of non active components. The probe performance shows a recovery time of about of 15μs a sensitive Q factor reduction and an increase of the signal to noise ratio of about 68% during the reception at a work frequency of 2 MHz. (author)

  2. Job quality of short-time workers and perception and support from their managers

    OpenAIRE

    坂爪, 洋美

    2017-01-01

    The purpose of this study was to clarify the relationship between the characteristics of job quality that short-time workers occupied and the managers’ perception and support whose member has used short-time working hour system. A total of 559 first-line managers who has a member using short-time working hour system completed a web-based survey assessing job quality of short-time workers , the risk of using short-timeworking hour system, career perspective of short-time workers, and the suppo...

  3. Real-time energy resources scheduling considering short-term and very short-term wind forecast

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Marco; Sousa, Tiago; Morais, Hugo; Vale, Zita [Polytechnic of Porto (Portugal). GECAD - Knowledge Engineering and Decision Support Research Center

    2012-07-01

    This paper proposes an energy resources management methodology based on three distinct time horizons: day-ahead scheduling, hour-ahead scheduling, and real-time scheduling. In each scheduling process the update of generation and consumption operation and of the storage and electric vehicles storage status are used. Besides the new operation conditions, the most accurate forecast values of wind generation and of consumption using results of short-term and very short-term methods are used. A case study considering a distribution network with intensive use of distributed generation and electric vehicles is presented. (orig.)

  4. Chirped or time modulated excitation compared to short pulses for photoacoustic imaging in acoustic attenuating media

    Science.gov (United States)

    Burgholzer, P.; Motz, C.; Lang, O.; Berer, T.; Huemer, M.

    2018-02-01

    In photoacoustic imaging, optically generated acoustic waves transport the information about embedded structures to the sample surface. Usually, short laser pulses are used for the acoustic excitation. Acoustic attenuation increases for higher frequencies, which reduces the bandwidth and limits the spatial resolution. One could think of more efficient waveforms than single short pulses, such as pseudo noise codes, chirped, or harmonic excitation, which could enable a higher information-transfer from the samples interior to its surface by acoustic waves. We used a linear state space model to discretize the wave equation, such as the Stoke's equation, but this method could be used for any other linear wave equation. Linear estimators and a non-linear function inversion were applied to the measured surface data, for onedimensional image reconstruction. The proposed estimation method allows optimizing the temporal modulation of the excitation laser such that the accuracy and spatial resolution of the reconstructed image is maximized. We have restricted ourselves to one-dimensional models, as for higher dimensions the one-dimensional reconstruction, which corresponds to the acoustic wave without attenuation, can be used as input for any ultrasound imaging method, such as back-projection or time-reversal method.

  5. Short echo time, fast gradient-echo imaging

    International Nuclear Information System (INIS)

    Haacke, E.M.; Lenz, G.W.

    1987-01-01

    Present fast-gradient-echoes schemes can acquire volume data rapidly and are flexible in T1 or T1/T2 contrast behavior. However, sequences used to date employ echo time (TE) values of about 15 ms +- 5 and, because of in vivo field inhomogeneities (short T2), they suffer badly from signal loss near sinuses and tissue boundaries. The authors implemented sequences with TE = 4-6 ms and found significant improvement in image quality, especially at high fields. Examples with long TEs vs. short TEs are given in the knee, spine, head, and orbits. Further advantages include (1) faster repetition times (15 ms), (2) higher-quality spin-density or T1-weighted images, and (3) reduction of blood motion artifacts

  6. Transient nanobubbles in short-time electrolysis

    NARCIS (Netherlands)

    Svetovoy, Vitaly; Sanders, Remco G.P.; Elwenspoek, Michael Curt

    2013-01-01

    Water electrolysis in a microsystem is observed and analyzed on a short-time scale of ∼10 μs. The very unusual properties of the process are stressed. An extremely high current density is observed because the process is not limited by the diffusion of electroactive species. The high current is

  7. Quantifying complexity of financial short-term time series by composite multiscale entropy measure

    Science.gov (United States)

    Niu, Hongli; Wang, Jun

    2015-05-01

    It is significant to study the complexity of financial time series since the financial market is a complex evolved dynamic system. Multiscale entropy is a prevailing method used to quantify the complexity of a time series. Due to its less reliability of entropy estimation for short-term time series at large time scales, a modification method, the composite multiscale entropy, is applied to the financial market. To qualify its effectiveness, its applications in the synthetic white noise and 1 / f noise with different data lengths are reproduced first in the present paper. Then it is introduced for the first time to make a reliability test with two Chinese stock indices. After conducting on short-time return series, the CMSE method shows the advantages in reducing deviations of entropy estimation and demonstrates more stable and reliable results when compared with the conventional MSE algorithm. Finally, the composite multiscale entropy of six important stock indices from the world financial markets is investigated, and some useful and interesting empirical results are obtained.

  8. A comparative analysis of short-range travel time prediction methods

    NARCIS (Netherlands)

    Huisken, Giovanni; van Berkum, Eric C.

    2003-01-01

    Increasing car mobility has lead to an increasing demand for traffic information. This contribution deals with information about travel times. When car drivers are provided with this type of information, the travel times should ideally be the times that they will encounter. As a result travel times

  9. Temporal Prediction Errors Affect Short-Term Memory Scanning Response Time.

    Science.gov (United States)

    Limongi, Roberto; Silva, Angélica M

    2016-11-01

    The Sternberg short-term memory scanning task has been used to unveil cognitive operations involved in time perception. Participants produce time intervals during the task, and the researcher explores how task performance affects interval production - where time estimation error is the dependent variable of interest. The perspective of predictive behavior regards time estimation error as a temporal prediction error (PE), an independent variable that controls cognition, behavior, and learning. Based on this perspective, we investigated whether temporal PEs affect short-term memory scanning. Participants performed temporal predictions while they maintained information in memory. Model inference revealed that PEs affected memory scanning response time independently of the memory-set size effect. We discuss the results within the context of formal and mechanistic models of short-term memory scanning and predictive coding, a Bayes-based theory of brain function. We state the hypothesis that our finding could be associated with weak frontostriatal connections and weak striatal activity.

  10. Comparative Short-Term Clinical Outcomes of Mediastinum Tumor Excision Performed by Conventional VATS and Single-Port VATS: Is It Worthwhile?

    Science.gov (United States)

    Wu, Ching-Feng; Gonzalez-Rivas, Diego; Wen, Chih-Tsung; Liu, Yun-Hen; Wu, Yi-Cheng; Chao, Yin-Kai; Hsieh, Ming-Ju; Wu, Ching-Yang; Chen, Wei-Hsun

    2015-11-01

    Single-port video-assisted thoracoscopic surgery (VATS) has been widely applied recently. However, there are still only few reports describing its use in mediastinum tumor resection. We present the technique of single-port video-assisted thoracoscopic mediastinum tumor resection and compare it with conventional VATS with regard to short-term outcome.We retrospectively enrolled 105 patients who received mediastinum surgery in Chang Gung Memorial Hospital. Sixteen patients received sternotomy or thoracotomy, 29 patients received single-port VATS, and 60 patients received conventional VATS (3 ports). The operative time, blood loss, postoperation day 1 pain score, discharge day pain score, and postoperative hospital stay were compared. In order to establish a well balanced cohort study, we also use propensity scores match (1:1) to compare the short-term clinical outcome in 2 groups.No operative deaths occurred in this study. Single-port VATS was associated with shorter operative time, lower postoperation day 1 pain score, and shorter postoperation hospital stay in our cohort study (P = 0.001, short-term outcome not inferior to conventional VATS in our cohort study. The long-term oncology outcome may require time and more enrolled patients to be further evaluated.

  11. Dimension reduction of frequency-based direct Granger causality measures on short time series.

    Science.gov (United States)

    Siggiridou, Elsa; Kimiskidis, Vasilios K; Kugiumtzis, Dimitris

    2017-09-01

    The mainstream in the estimation of effective brain connectivity relies on Granger causality measures in the frequency domain. If the measure is meant to capture direct causal effects accounting for the presence of other observed variables, as in multi-channel electroencephalograms (EEG), typically the fit of a vector autoregressive (VAR) model on the multivariate time series is required. For short time series of many variables, the estimation of VAR may not be stable requiring dimension reduction resulting in restricted or sparse VAR models. The restricted VAR obtained by the modified backward-in-time selection method (mBTS) is adapted to the generalized partial directed coherence (GPDC), termed restricted GPDC (RGPDC). Dimension reduction on other frequency based measures, such the direct directed transfer function (dDTF), is straightforward. First, a simulation study using linear stochastic multivariate systems is conducted and RGPDC is favorably compared to GPDC on short time series in terms of sensitivity and specificity. Then the two measures are tested for their ability to detect changes in brain connectivity during an epileptiform discharge (ED) from multi-channel scalp EEG. It is shown that RGPDC identifies better than GPDC the connectivity structure of the simulated systems, as well as changes in the brain connectivity, and is less dependent on the free parameter of VAR order. The proposed dimension reduction in frequency measures based on VAR constitutes an appropriate strategy to estimate reliably brain networks within short-time windows. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Short-time, high-dosage penicillin infusion therapy of syphilis

    DEFF Research Database (Denmark)

    Lomholt, Hans; Poulsen, Asmus; Brandrup, Flemming

    2003-01-01

    The optimal dosage and duration of penicillin treatment for the various stages of syphilis are not known. We present data on 20 patients with syphilis (primary, secondary or latent) treated with high-dose, short-time penicillin infusion therapy. Patients were given 10 MIU of penicillin G intraven......The optimal dosage and duration of penicillin treatment for the various stages of syphilis are not known. We present data on 20 patients with syphilis (primary, secondary or latent) treated with high-dose, short-time penicillin infusion therapy. Patients were given 10 MIU of penicillin G...

  13. Photoluminescence decay dynamics in γ-Ga2O3 nanocrystals: The role of exclusion distance at short time scales

    Science.gov (United States)

    Fernandes, Brian; Hegde, Manu; Stanish, Paul C.; Mišković, Zoran L.; Radovanovic, Pavle V.

    2017-09-01

    We developed a comprehensive theoretical model describing the photoluminescence decay dynamics at short and long time scales based on the donor-acceptor defect interactions in γ-Ga2O3 nanocrystals, and quantitatively determined the importance of exclusion distance and spatial distribution of defects. We allowed for donors and acceptors to be adjacent to each other or separated by different exclusion distances. The optimal exclusion distance was found to be comparable to the donor Bohr radius and have a strong effect on the photoluminescence decay curve at short times. The importance of the exclusion distance at short time scales was confirmed by Monte Carlo simulations.

  14. The loss of short-term visual representations over time: decay or temporal distinctiveness?

    Science.gov (United States)

    Mercer, Tom

    2014-12-01

    There has been much recent interest in the loss of visual short-term memories over the passage of time. According to decay theory, visual representations are gradually forgotten as time passes, reflecting a slow and steady distortion of the memory trace. However, this is controversial and decay effects can be explained in other ways. The present experiment aimed to reexamine the maintenance and loss of visual information over the short term. Decay and temporal distinctiveness models were tested using a delayed discrimination task, in which participants compared complex and novel objects over unfilled retention intervals of variable length. Experiment 1 found no significant change in the accuracy of visual memory from 2 to 6 s, but the gap separating trials reliably influenced task performance. Experiment 2 found evidence for information loss at a 10-s retention interval, but temporally separating trials restored the fidelity of visual memory, possibly because temporally isolated representations are distinct from older memory traces. In conclusion, visual representations lose accuracy at some point after 6 s, but only within temporally crowded contexts. These findings highlight the importance of temporal distinctiveness within visual short-term memory. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  15. A short history of fractal-Cantorian space-time

    International Nuclear Information System (INIS)

    Marek-Crnjac, L.

    2009-01-01

    The article attempts to give a short historical overview of the discovery of fractal-Cantorian space-time starting from the 17th century up to the present. In the last 25 years a great number of scientists worked on fractal space-time notably Garnet Ord in Canada, Laurent Nottale in France and Mohamed El Naschie in England who gave an exact mathematical procedure for the derivation of the dimensionality and curvature of fractal space-time fuzzy manifold.

  16. Clinical observation of one time short-pulse pattern scan laser pan-retinal photocoagulation for proliferative diabetic retinopathy

    Directory of Open Access Journals (Sweden)

    Xin Liu

    2016-04-01

    Full Text Available AIM: To investigate the clinical efficacy and benefit of short-pulse pattern scan laser(PASCALphotocoagulation for proliferative diabetic retinopathy(PDR.METHODS:Twenty-eight PDR patients(42 eyesunderwent short-pulse PASCAL pan-retinal photocoagulation(PRPwere analyzed.The best corrected visual acuity was ≥0.1 in 36 eyes, RESULTS: All the cases had no pain during the short-pulse PASCAL treatment.One year after treatments,the final visual acuity was improved in 6 eyes,kept stable in 28 eyes and decreased in 8 eyes; neovascularization were regressed in 18 eyes(43%, stable in 12 eyes(29%, uncontrolled in 12 eyes(29%. Five eyes(12%received vitrectomy due to vitreous hemorrhage.Compared with before operation, retina thickness in central fovea of macula and visual field had no obvious change after one-time PASCAL PRP(P>0.05. CONCLUSION:The one-time short-pulse PASCAL PRP could stabilize the progress of PDR safely, effectively and simply.

  17. Pigeon visual short-term memory directly compared to primates.

    Science.gov (United States)

    Wright, Anthony A; Elmore, L Caitlin

    2016-02-01

    Three pigeons were trained to remember arrays of 2-6 colored squares and detect which of two squares had changed color to test their visual short-term memory. Procedures (e.g., stimuli, displays, viewing times, delays) were similar to those used to test monkeys and humans. Following extensive training, pigeons performed slightly better than similarly trained monkeys, but both animal species were considerably less accurate than humans with the same array sizes (2, 4 and 6 items). Pigeons and monkeys showed calculated memory capacities of one item or less, whereas humans showed a memory capacity of 2.5 items. Despite the differences in calculated memory capacities, the pigeons' memory results, like those from monkeys and humans, were all well characterized by an inverse power-law function fit to d' values for the five display sizes. This characterization provides a simple, straightforward summary of the fundamental processing of visual short-term memory (how visual short-term memory declines with memory load) that emphasizes species similarities based upon similar functional relationships. By closely matching pigeon testing parameters to those of monkeys and humans, these similar functional relationships suggest similar underlying processes of visual short-term memory in pigeons, monkeys and humans. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Optimum short-time polynomial regression for signal analysis

    Indian Academy of Sciences (India)

    A Sreenivasa Murthy

    the Proceedings of European Signal Processing Conference. (EUSIPCO) 2008. ... In a seminal paper, Savitzky and Golay [4] showed that short-time polynomial modeling is ...... We next consider a linearly frequency-modulated chirp with an exponentially .... 1 http://www.physionet.org/physiotools/matlab/ECGwaveGen/.

  19. Difference-based clustering of short time-course microarray data with replicates

    Directory of Open Access Journals (Sweden)

    Kim Jihoon

    2007-07-01

    Full Text Available Abstract Background There are some limitations associated with conventional clustering methods for short time-course gene expression data. The current algorithms require prior domain knowledge and do not incorporate information from replicates. Moreover, the results are not always easy to interpret biologically. Results We propose a novel algorithm for identifying a subset of genes sharing a significant temporal expression pattern when replicates are used. Our algorithm requires no prior knowledge, instead relying on an observed statistic which is based on the first and second order differences between adjacent time-points. Here, a pattern is predefined as the sequence of symbols indicating direction and the rate of change between time-points, and each gene is assigned to a cluster whose members share a similar pattern. We evaluated the performance of our algorithm to those of K-means, Self-Organizing Map and the Short Time-series Expression Miner methods. Conclusions Assessments using simulated and real data show that our method outperformed aforementioned algorithms. Our approach is an appropriate solution for clustering short time-course microarray data with replicates.

  20. Real-time mobile customer short message system design and implementation

    Science.gov (United States)

    Han, Qirui; Sun, Fang

    To expand the current mobile phone short message service, and to make the contact between schools, teachers, parents and feedback of the modern school office system more timely and conveniently, designed and developed the Short Message System based on the Linux platform. The state-of-the-art principles and designed proposals in the Short Message System based on the Linux platform are introduced. Finally we propose an optimized secure access authentication method. At present, many schools,vbusinesses and research institutions ratify the promotion and application the messaging system gradually, which has shown benign market prospects.

  1. X-ray testing for short-time dynamic applications

    International Nuclear Information System (INIS)

    Kurfiss, Malte; Moser, Stefan; Popko, Gregor; Nau, Siegfried

    2017-01-01

    For nondestructive testing purposes new challenges are short-time dynamic processes. The application of x-ray flash tubes and modern high-speed cameras allows the observation of the opening of air-bags or the energy absorption of compressed tubes as occurring during a vehicle crash. Special algorithms designed for computerized tomography analyses allow the 3D reconstruction at individual time points of the dynamic process. Possibilities and limitations of the actual techniques are discussed.

  2. The Validity and Precision of the Comparative Interrupted Time-Series Design: Three Within-Study Comparisons

    Science.gov (United States)

    St. Clair, Travis; Hallberg, Kelly; Cook, Thomas D.

    2016-01-01

    We explore the conditions under which short, comparative interrupted time-series (CITS) designs represent valid alternatives to randomized experiments in educational evaluations. To do so, we conduct three within-study comparisons, each of which uses a unique data set to test the validity of the CITS design by comparing its causal estimates to…

  3. Extracting biologically significant patterns from short time series gene expression data

    Directory of Open Access Journals (Sweden)

    McGinnis Thomas

    2009-08-01

    Full Text Available Abstract Background Time series gene expression data analysis is used widely to study the dynamics of various cell processes. Most of the time series data available today consist of few time points only, thus making the application of standard clustering techniques difficult. Results We developed two new algorithms that are capable of extracting biological patterns from short time point series gene expression data. The two algorithms, ASTRO and MiMeSR, are inspired by the rank order preserving framework and the minimum mean squared residue approach, respectively. However, ASTRO and MiMeSR differ from previous approaches in that they take advantage of the relatively few number of time points in order to reduce the problem from NP-hard to linear. Tested on well-defined short time expression data, we found that our approaches are robust to noise, as well as to random patterns, and that they can correctly detect the temporal expression profile of relevant functional categories. Evaluation of our methods was performed using Gene Ontology (GO annotations and chromatin immunoprecipitation (ChIP-chip data. Conclusion Our approaches generally outperform both standard clustering algorithms and algorithms designed specifically for clustering of short time series gene expression data. Both algorithms are available at http://www.benoslab.pitt.edu/astro/.

  4. Feasibility of deep-inspiration breath-hold PET/CT with short-time acquisition. Detectability for pulmonary lesions compared with respiratory-gated PET/CT

    International Nuclear Information System (INIS)

    Yamashita, Shozo; Yamamoto, Haruki; Hiko, Shigeaki; Horita, Akihiro; Yokoyama, Kunihiko; Onoguchi, Masahisa; Nakajima, Kenichi

    2014-01-01

    Deep-inspiration breath-hold (DIBH) positron emission tomography (PET)/CT with short-time acquisition and respiratory-gated (RG) PET/CT are performed for pulmonary lesions to reduce the respiratory motion artifacts, and to obtain more accurate standardized uptake value (SUV). DIBH PET/CT demonstrates significant advantages in terms of rapid examination, good quality of CT images and low radiation exposure. On the other hand, the image quality of DIBH PET is generally inferior to that of RG PET because of short-time acquisition resulting in poor signal-to-noise ratio. In this study, RG PET has been regarded as a gold standard, and its detectability between DIBH and RG PET studies was compared using each of the most optimal reconstruction parameters. In the phantom study, the most optimal reconstruction parameters for DIBH and RG PET were determined. In the clinical study, 19 cases were examined using each of the most optimal reconstruction parameters. In the phantom study, the most optimal reconstruction parameters for DIBH and RG PET were different. Reconstruction parameters of DIBH PET could be obtained by reducing the number of subsets for those of RG PET in the state of fixing the number of iterations. In the clinical study, high correlation in the maximum SUV was observed between DIBH and RG PET studies. The clinical result was consistent with that of the phantom study surrounded by air since most of the lesions were located in the low pulmonary radioactivity. DIBH PET/CT may be the most practical method which can be the first choice to reduce respiratory motion artifacts if the detectability of DIBH PET is equivalent with that of RG PET. Although DIBH PET may have limitations in suboptimal signal-to-noise ratio, most of the lesions surrounded by low background radioactivity could provide nearly equivalent image quality between DIBH and RG PET studies when each of the most optimal reconstruction parameters was used. (author)

  5. Metabolic changes in the normal ageing brain: Consistent findings from short and long echo time proton spectroscopy

    International Nuclear Information System (INIS)

    Gruber, S.; Pinker, K.; Riederer, F.; Chmelik, M.; Stadlbauer, A.; Bittsansky, M.; Mlynarik, V.; Frey, R.; Serles, W.; Bodamer, O.; Moser, E.

    2008-01-01

    Objectives: Sixty three healthy subjects were measured to assess dependence of brain metabolites on age using short- and long echo time spectroscopy in different brain regions. Material and methods: Younger and elderly humans were measured with long echo time (TE = 135 ms) 3D-MR-spectroscopic imaging (MRSI) (10 subjects) and with ultra-short echo (TE = 11 ms) time 2D-MRSI (7 subjects). In addition, results from single voxel 1 H-spectroscopy (TE = 20 ms) of two cohorts of 46 healthy subjects were retrospectively correlated with age. Results: 3D-MR SI revealed reduced NAA/Cr in the older group in the frontal lobe (-22%; p < 0.01), parietal lobe (-28%; p < 0.01) and semiovale (-9%; p < 0.01) compared to the younger group. Cho/Cr was elevated in the semiovale (+35%; p < 0.01) and in the n. lentiformis (+42%; p < 0.01) in the older group. NAA/Cho was reduced in all regions measured, except the thalamus, in the older group compared to the younger group (from -21 to -49%; p < 0.01). 2D-MRSI revealed decreased total NAA (-3.1% per decade; p < 0.01) and NAA/Cr (-3.8% per decade; p < 0.01), increased total Cho (+3.6% per decade; p < 0.01) and Cho/Cr (+4.6% per decade; p < 0.01) and increased total myo-Inositol (mI, +4.7% per decade; p < 0.01) and mI/Cr (+5.4% per decade; p < 0.01) and decreased NAA/Cho (-8% per decade; p < 0.01) in semiovale WM. Results from single voxel spectroscopy revealed a significantly negative correlation of NAA/Cho in frontal (-13% per decade; p < 0.01) and in temporal lobe (-7.4% per decade; p < 0.01) as well as increased total Cr (10% per decade; p < 0.01) in frontal lobe. Other results from single voxel measurements were not significant, but trends were comparable to that from multivoxel spectroscopy. Conclusion: Age-related changes measured with long echo time and short echo time 1H-MRS were comparable and cannot, therefore, be caused by different T2 relaxation times in young and old subjects, as suggested previously

  6. The short-term effects of air pollutants on respiratory disease mortality in Wuhan, China: comparison of time-series and case-crossover analyses

    OpenAIRE

    Meng Ren; Na Li; Zhan Wang; Yisi Liu; Xi Chen; Yuanyuan Chu; Xiangyu Li; Zhongmin Zhu; Liqiao Tian; Hao Xiang

    2017-01-01

    Few studies have compared different methods when exploring the short-term effects of air pollutants on respiratory disease mortality in Wuhan, China. This study assesses the association between air pollutants and respiratory disease mortality with both time-series and time-stratified?case-crossover designs. The generalized additive model (GAM) and the conditional logistic regression model were used to assess the short-term effects of air pollutants on respiratory disease mortality. Stratified...

  7. A characterization of persistence at short times in the WFC3/IR detector

    Science.gov (United States)

    Gennaro, M.; Bajaj, V.; Long, K.

    2018-05-01

    Persistence in the WFC3/IR detector appears to decay as a power law as a function of time elapsed since the end of a stimulus. In this report we study departures from the power law at times shorter than a few hundreds seconds after the stimulus. In order to have better short-time cadence, we use the Multiaccum (.ima) files, which trace the accumulated charge in the pixels as function of time, rather than the final pipeline products (.flt files), which instead report the electron rate estimated via a linear fit to the accumulated charge vs. time relation. We note that at short times after the stimulus, the absolute change in persistence is the strongest, thus a linear fit to the accumulated signal (the .flt values) can be a poor representation of the strongly varying persistence signal. The already observed power-law decay of the persistence signal, still holds at shorter times, with typical values of the power law index, gamma in [-0.8,-1] for stimuli that saturate the WFC3 pixels. To a good degree of approximation, a single power law is a good fit to the persistence signal decay from 100 to 5000 seconds. We also detect a tapering-off in the power-law decay at increasingly shorter times. This change in behavior is of the order of Delta Gamma 0.02 - 0.05 when comparing power-law fits performed to the persistence signal from 0 up to 250 seconds and from 0 up to 4000 seconds after the stimulus, indicating that persistence decays slightly more rapidly as time progresses. Our results may suggest that for even shorter times, not probed by our study, the WFC3 persistence signal might deviate from a single power-law model.

  8. Age and admission times as predictive factors for failure of admissions to discharge-stream short-stay units.

    Science.gov (United States)

    Shetty, Amith L; Shankar Raju, Savitha Banagar; Hermiz, Arsalan; Vaghasiya, Milan; Vukasovic, Matthew

    2015-02-01

    Discharge-stream emergency short-stay units (ESSU) improve ED and hospital efficiency. Age of patients and time of hospital presentations have been shown to correlate with increasing complexity of care. We aim to determine whether an age and time cut-off could be derived to subsequently improve short-stay unit success rates. We conducted a retrospective audit on 6703 (5522 inclusions) patients admitted to our discharge-stream short-stay unit. Patients were classified as appropriate or inappropriate admissions, and deemed successful if discharged out of the unit within 24 h; and failures if they needed inpatient admission into the hospital. We calculated short-stay unit length of stay for patients in each of these groups. A 15% failure rate was deemed as acceptable key performance indicator (KPI) for our unit. There were 197 out of 4621 (4.3%, 95% CI 3.7-4.9%) patients up to the age of 70 who failed admission to ESSU compared with 67 out of 901 (7.4%, 95% CI 5.9-9.3%, P 70 years of age have higher rates of failure after admission to discharge-stream ESSU. Although in appropriately selected discharge-stream patients, no age group or time-band of presentation was associated with increased failure rate beyond the stipulated KPI. © 2014 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  9. [Possibilities in the differential diagnosis of brain neoplasms using the long and short time sequences of proton magnetic resonance spectroscopy

    NARCIS (Netherlands)

    Gajewicz, W.; Goraj, B.M.

    2004-01-01

    Currently to perform proton magnetic resonance spectroscopy (1H MRS) with single voxel spectroscopy (SVS) technique long and/or short echo time sequences are used in order to provide complementary information. PURPOSE: The aim of the study was to compare the usefulness of STEAM (time echo, TE, 20

  10. Evaluation of scaling invariance embedded in short time series.

    Directory of Open Access Journals (Sweden)

    Xue Pan

    Full Text Available Scaling invariance of time series has been making great contributions in diverse research fields. But how to evaluate scaling exponent from a real-world series is still an open problem. Finite length of time series may induce unacceptable fluctuation and bias to statistical quantities and consequent invalidation of currently used standard methods. In this paper a new concept called correlation-dependent balanced estimation of diffusion entropy is developed to evaluate scale-invariance in very short time series with length ~10(2. Calculations with specified Hurst exponent values of 0.2,0.3,...,0.9 show that by using the standard central moving average de-trending procedure this method can evaluate the scaling exponents for short time series with ignorable bias (≤0.03 and sharp confidential interval (standard deviation ≤0.05. Considering the stride series from ten volunteers along an approximate oval path of a specified length, we observe that though the averages and deviations of scaling exponents are close, their evolutionary behaviors display rich patterns. It has potential use in analyzing physiological signals, detecting early warning signals, and so on. As an emphasis, the our core contribution is that by means of the proposed method one can estimate precisely shannon entropy from limited records.

  11. Evaluation of scaling invariance embedded in short time series.

    Science.gov (United States)

    Pan, Xue; Hou, Lei; Stephen, Mutua; Yang, Huijie; Zhu, Chenping

    2014-01-01

    Scaling invariance of time series has been making great contributions in diverse research fields. But how to evaluate scaling exponent from a real-world series is still an open problem. Finite length of time series may induce unacceptable fluctuation and bias to statistical quantities and consequent invalidation of currently used standard methods. In this paper a new concept called correlation-dependent balanced estimation of diffusion entropy is developed to evaluate scale-invariance in very short time series with length ~10(2). Calculations with specified Hurst exponent values of 0.2,0.3,...,0.9 show that by using the standard central moving average de-trending procedure this method can evaluate the scaling exponents for short time series with ignorable bias (≤0.03) and sharp confidential interval (standard deviation ≤0.05). Considering the stride series from ten volunteers along an approximate oval path of a specified length, we observe that though the averages and deviations of scaling exponents are close, their evolutionary behaviors display rich patterns. It has potential use in analyzing physiological signals, detecting early warning signals, and so on. As an emphasis, the our core contribution is that by means of the proposed method one can estimate precisely shannon entropy from limited records.

  12. Computation of the Short-Time Linear Canonical Transform with Dual Window

    Directory of Open Access Journals (Sweden)

    Lei Huang

    2017-01-01

    Full Text Available The short-time linear canonical transform (STLCT, which maps the time domain signal into the joint time and frequency domain, has recently attracted some attention in the area of signal processing. However, its applications are still limited due to the fact that selection of coefficients of the short-time linear canonical series (STLCS is not unique, because time and frequency elementary functions (together known as basis function of STLCS do not constitute an orthogonal basis. To solve this problem, this paper investigates a dual window solution. First, the nonorthogonal problem that suffered from original window is fulfilled by orthogonal condition with dual window. Then based on the obtained condition, a dual window computation approach of the GT is extended to the STLCS. In addition, simulations verify the validity of the proposed condition and solutions. Furthermore, some possible applied directions are discussed.

  13. Are anomalously short tunnelling times measurable?

    International Nuclear Information System (INIS)

    Delgado, V.; Muga, J.G.

    1996-01-01

    Low and Mende have analyzed the conditions that would make possible an actual measurement of an anomalously short traversal time through a potential barrier concluding that such a measurement cannot be made because it is not possible to describe the tunnelling of a wave packet initially close to the barrier by the open-quote open-quote usual wave packet space time analysis close-quote close-quote. We complement this work in several ways: It is argued that the described failure of the usual formalism occurs under a set of too restrictive conditions, some of them not physically motivated, so it does not necessarily imply the impossibility of such a measurement. However, by retaining only conditions well motivated on physical grounds we have performed a systematic numerical check which shows that the conclusion by Low and Mende is indeed generally valid. It is shown that, as speculated by Low and Mende, the process is dominated by over the barrier transmission. Copyright copyright 1996 Academic Press, Inc

  14. Directional short-time Fourier transform of distributions

    Directory of Open Access Journals (Sweden)

    Katerina Hadzi-Velkova Saneva

    2016-04-01

    Full Text Available Abstract In this paper we consider the directional short-time Fourier transform (DSTFT that was introduced and investigated in (Giv in J. Math. Anal. Appl. 399:100-107, 2013. We analyze the DSTFT and its transpose on test function spaces S ( R n $\\mathcal {S}(\\mathbb {R}^{n}$ and S ( Y 2 n $\\mathcal {S}(\\mathbb {Y}^{2n}$ , respectively, and prove the continuity theorems on these spaces. Then the obtained results are used to extend the DSTFT to spaces of distributions.

  15. Response probability and response time: a straight line, the Tagging/Retagging interpretation of short term memory, an operational definition of meaningfulness and short term memory time decay and search time.

    Science.gov (United States)

    Tarnow, Eugen

    2008-12-01

    The functional relationship between correct response probability and response time is investigated in data sets from Rubin, Hinton and Wenzel, J Exp Psychol Learn Mem Cogn 25:1161-1176, 1999 and Anderson, J Exp Psychol [Hum Learn] 7:326-343, 1981. The two measures are linearly related through stimulus presentation lags from 0 to 594 s in the former experiment and for repeated learning of words in the latter. The Tagging/Retagging interpretation of short term memory is introduced to explain this linear relationship. At stimulus presentation the words are tagged. This tagging level drops slowly with time. When a probe word is reintroduced the tagging level has to increase for the word to be properly identified leading to a delay in response time. The tagging time is related to the meaningfulness of the words used-the more meaningful the word the longer the tagging time. After stimulus presentation the tagging level drops in a logarithmic fashion to 50% after 10 s and to 20% after 240 s. The incorrect recall and recognition times saturate in the Rubin et al. data set (they are not linear for large time lags), suggesting a limited time to search the short term memory structure: the search time for recall of unusual words is 1.7 s. For recognition of nonsense words the corresponding time is about 0.4 s, similar to the 0.243 s found in Cavanagh (1972).

  16. PASTEURISASI HIGH TEMPERATURE SHORT TIME (HTST) SUSU TERHADAP Listeria monocytogenes PADA PENYIMPANAN REFRIGERATOR

    OpenAIRE

    SABIL, SYAHRIANA

    2015-01-01

    2015 SYAHRIANA SABIL (I 111 11 273). Pasteurisasi High Temperature Short Time (HTST) Susu terhadap Listeria monocytogenes pada Penyimpanan Refrigerator. Dibimbing oleh RATMAWATI MALAKA dan FARIDA NUR YULIATI. Pasteurisasi High Temperature Short Time (HTST) merupakan proses pemanasan susu di bawah titik didih yang diharapkan dapat membunuh Listeria monocytogenes (L. monocytogenes) karena bersifat patogen dan mengakibatkan listeriosis yang merupakan penyakit zoonosis. Tu...

  17. Time-dependent Bragg diffraction and short-pulse reflection by one-dimensional photonic crystals

    International Nuclear Information System (INIS)

    André, Jean-Michel; Jonnard, Philippe

    2015-01-01

    The time-dependence of the Bragg diffraction by one-dimensional photonic crystals and its influence on the short pulse reflection are studied in the framework of the coupled-wave theory. The indicial response of the photonic crystal is calculated and it appears that it presents a time-delay effect with a transient time conditioned by the extinction length. A numerical simulation is presented for a Bragg mirror in the x-ray domain and a pulse envelope modelled by a sine-squared shape. The potential consequences of the time-delay effect in time-dependent optics of short-pulses are emphasized. (paper)

  18. Short-time perturbation theory and nonrelativistic duality

    International Nuclear Information System (INIS)

    Whitenton, J.B.; Durand, B.; Durand, L.

    1983-01-01

    We give a simple proof of the nonrelativistic duality relation 2 sigma/sub bound/>roughly-equal 2 sigma/sub free/> for appropriate energy averages of the cross sections for e + e - →(qq-bar bound states) and e + e - →(free qq-bar pair), and calculate the corrections to the relation by relating W 2 sigma to the Fourier transform of the Feynman propagation function and developing a short-time perturbation series for that function. We illustrate our results in detail for simple power-law potentials and potentials which involve combinations of powers

  19. Equivalence between short-time biphasic and incompressible elastic material responses.

    Science.gov (United States)

    Ateshian, Gerard A; Ellis, Benjamin J; Weiss, Jeffrey A

    2007-06-01

    Porous-permeable tissues have often been modeled using porous media theories such as the biphasic theory. This study examines the equivalence of the short-time biphasic and incompressible elastic responses for arbitrary deformations and constitutive relations from first principles. This equivalence is illustrated in problems of unconfined compression of a disk, and of articular contact under finite deformation, using two different constitutive relations for the solid matrix of cartilage, one of which accounts for the large disparity observed between the tensile and compressive moduli in this tissue. Demonstrating this equivalence under general conditions provides a rationale for using available finite element codes for incompressible elastic materials as a practical substitute for biphasic analyses, so long as only the short-time biphasic response is sought. In practice, an incompressible elastic analysis is representative of a biphasic analysis over the short-term response deltatelasticity tensor, and K is the hydraulic permeability tensor of the solid matrix. Certain notes of caution are provided with regard to implementation issues, particularly when finite element formulations of incompressible elasticity employ an uncoupled strain energy function consisting of additive deviatoric and volumetric components.

  20. Determination of Permissible Short-Time Emergency Overloading of Turbo-Generators and Synchronous Compensators

    Directory of Open Access Journals (Sweden)

    V. A. Anischenko

    2011-01-01

    Full Text Available The paper shows that failure to take into account variable ratio of short-time emergency overloading of turbo-generators (synchronous compensators that can lead to underestimation of overloading capacity or impermissible insulation over-heating.A method has been developed for determination of permissible duration of short-time emergency over-loading that takes into account changes of over-loading ratio in case of a failure.

  1. What do short-term and long-term relationships look like? Building the relationship coordination and strategic timing (ReCAST) model.

    Science.gov (United States)

    Eastwick, Paul W; Keneski, Elizabeth; Morgan, Taylor A; McDonald, Meagan A; Huang, Sabrina A

    2018-05-01

    Close relationships research has examined committed couples (e.g., dating relationships, marriages) using intensive methods that plot relationship development over time. But a substantial proportion of people's real-life sexual experiences take place (a) before committed relationships become "official" and (b) in short-term relationships; methods that document the time course of relationships have rarely been applied to these contexts. We adapted a classic relationship trajectory-plotting technique to generate the first empirical comparisons between the features of people's real-life short-term and long-term relationships across their entire timespan. Five studies compared long-term and short-term relationships in terms of the timing of relationship milestones (e.g., flirting, first sexual intercourse) and the occurrence/intensity of important relationship experiences (e.g., romantic interest, strong sexual desire, attachment). As romantic interest was rising and partners were becoming acquainted, long-term and short-term relationships were indistinguishable. Eventually, romantic interest in short-term relationships plateaued and declined while romantic interest in long-term relationships continued to rise, ultimately reaching a higher peak. As relationships progressed, participants evidenced more features characteristic of the attachment-behavioral system (e.g., attachment, caregiving) in long-term than short-term relationships but similar levels of other features (e.g., sexual desire, self-promotion, intrasexual competition). These data inform a new synthesis of close relationships and evolutionary psychological perspectives called the Relationship Coordination and Strategic Timing (ReCAST) model. ReCAST depicts short-term and long-term relationships as partially overlapping trajectories (rather than relationships initiated with distinct strategies) that differ in their progression along a normative relationship development sequence. (PsycINFO Database Record (c

  2. Comparing the Effectiveness of a Short-Term Vertical Jump vs. Weightlifting Program on Athletic Power Development.

    Science.gov (United States)

    Teo, Shaun Y M; Newton, Michael J; Newton, Robert U; Dempsey, Alasdair R; Fairchild, Timothy J

    2016-10-01

    Teo, SYM, Newton, MJ, Newton, RU, Dempsey, AR, and Fairchild, TJ. Comparing the effectiveness of a short-term vertical jump vs. weightlifting program on athletic power development. J Strength Cond Res 30(10): 2741-2748, 2016-Efficient training of neuromuscular power and the translation of this power to sport-specific tasks is a key objective in the preparation of athletes involved in team-based sports. The purpose of this study was to compare changes in center of mass (COM) neuromuscular power and performance of sport-specific tasks after short-term (6-week) training adopting either Olympic-style weightlifting (WL) exercises or vertical jump (VJ) exercises. Twenty-six recreationally active men (18-30 years; height: 178.7 ± 8.3 cm; mass: 78.6 ± 12.2 kg) were randomly allocated to either a WL or VJ training group and performance during the countermovement jump (CMJ), squat jump (SJ), depth jump (DJ), 20-m sprint, and the 5-0-5 agility test-assessed pre and posttraining. Despite the WL group demonstrating larger increases in peak power output during the CMJ (WL group: 10% increase, d = 0.701; VJ group: 5.78% increase, d = 0.328) and SJ (WL group: 12.73% increase, d = 0.854; VJ group: 7.27% increase, d = 0.382), no significant between-group differences were observed in any outcome measure studied. There was a significant main effect of time observed for the 3 VJs (CMJ, SJ, and DJ), 0- to 5-m and 0- to 20-m sprint times, and the 5-0-5 agility test time, which were all shown to improve after the training (all main effects of time p sports, even in athletes with limited preseason training periods.

  3. Analysis of Seasonal Signal in GPS Short-Baseline Time Series

    Science.gov (United States)

    Wang, Kaihua; Jiang, Weiping; Chen, Hua; An, Xiangdong; Zhou, Xiaohui; Yuan, Peng; Chen, Qusen

    2018-04-01

    Proper modeling of seasonal signals and their quantitative analysis are of interest in geoscience applications, which are based on position time series of permanent GPS stations. Seasonal signals in GPS short-baseline (paper, to better understand the seasonal signal in GPS short-baseline time series, we adopted and processed six different short-baselines with data span that varies from 2 to 14 years and baseline length that varies from 6 to 1100 m. To avoid seasonal signals that are overwhelmed by noise, each of the station pairs is chosen with significant differences in their height (> 5 m) or type of the monument. For comparison, we also processed an approximately zero baseline with a distance of pass-filtered (BP) noise is valid for approximately 40% of the baseline components, and another 20% of the components can be best modeled by a combination of the first-order Gauss-Markov (FOGM) process plus white noise (WN). The TEM displacements are then modeled by considering the monument height of the building structure beneath the GPS antenna. The median contributions of TEM to the annual amplitude in the vertical direction are 84% and 46% with and without additional parts of the monument, respectively. Obvious annual signals with amplitude > 0.4 mm in the horizontal direction are observed in five short-baselines, and the amplitudes exceed 1 mm in four of them. These horizontal seasonal signals are likely related to the propagation of daily/sub-daily TEM displacement or other signals related to the site environment. Mismodeling of the tropospheric delay may also introduce spurious seasonal signals with annual amplitudes of 5 and 2 mm, respectively, for two short-baselines with elevation differences greater than 100 m. The results suggest that the monument height of the additional part of a typical GPS station should be considered when estimating the TEM displacement and that the tropospheric delay should be modeled cautiously, especially with station pairs with

  4. The effect of short-time active listening training.

    Science.gov (United States)

    Tatsumi, Asami; Sumiyoshi, Kenichi; Kawaguchi, Hitomi; Sano, Yukiko

    2010-01-01

    administered 4 times, from before training to 6 mo afterward, and analysis was conducted for 84 respondents. No significant difference was seen in attitude to listening, but the score increased compared with before the training. The score for method of listening increased significantly. The same results were seen when the analysis was expanded to 125 respondents before and 6 mo after the training. These results are similar to those reported previously for ALAS. The findings suggest that even short listening training of 2 h and 30 min has a positive lasting effect.

  5. Innovation: study of 'ultra-short' time reactions

    International Nuclear Information System (INIS)

    Anon.

    2001-01-01

    This short article presents the new Elyse facility of Orsay-Paris 11 university for the study of ultra-short chemical and biochemical phenomena. Elyse uses the 'pump-probe' technique which consists in two perfectly synchronized electron and photon pulses. It comprises a 3 to 9 MeV electron accelerator with a HF gun photo-triggered with a laser. Elyse can initiate reactions using ultra-short electron pulses (radiolysis) or ultra-short photon pulses (photolysis). (J.S.)

  6. Short time propagation of a singular wave function: Some surprising results

    Science.gov (United States)

    Marchewka, A.; Granot, E.; Schuss, Z.

    2007-08-01

    The Schrödinger evolution of an initially singular wave function was investigated. First it was shown that a wide range of physical problems can be described by initially singular wave function. Then it was demonstrated that outside the support of the initial wave function the time evolution is governed to leading order by the values of the wave function and its derivatives at the singular points. Short-time universality appears where it depends only on a single parameter—the value at the singular point (not even on its derivatives). It was also demonstrated that the short-time evolution in the presence of an absorptive potential is different than in the presence of a nonabsorptive one. Therefore, this dynamics can be harnessed to the determination whether a potential is absorptive or not simply by measuring only the transmitted particles density.

  7. The study of the possibility to use CAMEX chips in collider experiments with short bunch crossing time

    International Nuclear Information System (INIS)

    Aulchenko, V.M.; Chilingarov, A.G.; Serbo, V.V.; Titov, V.M.

    1993-01-01

    The study of the possibility to use CAMEX chips in several systems of the detector KEDR at the e + e - collider VEPP-4M was performed. The relatively short bunch crossing time at VEPP-4M 60 ns leads to some problems with the use of CAMEX in the standard mode. The different ways to overcome these difficulties are investigated and compared. (orig.)

  8. Short-time scale coupling between thermohaline and meteorological forcing in the Ría de Pontevedra

    Directory of Open Access Journals (Sweden)

    Paula C. Pardo

    2001-07-01

    Full Text Available Two cruises were performed in May-June and October-November 1997 in the Ría de Pontevedra under strong downwelling conditions. Temperature and salinity data were recorded in short sampling periods to describe the changes in thermohaline property distribution in a short time scale. In order to obtain the residual fluxes in the Ría, a bi-dimensional non-stationary salt and thermal-energy weight averaged box-model was applied. Outputs from this kinematic model were compared with Upwelling Index, river flow and density gradient, resulting in a good multiple correlation, which proves the strong coupling between thermohaline properties and meteorological variability. Ekman forcing affects the whole area but mainly controls the dynamics of outer zones. The intensity of its effect on the circulation pattern within the Ría depends on the grade of stratification of the water bodies. River flow is more relevant in inner parts. According to estimated spatially averaged velocities, water residence time is lower than two weeks in outer parts of the Ría, and decreases toward the inner zones.

  9. Corrections for the combined effects of decay and dead time in live-timed counting of short-lived radionuclides

    International Nuclear Information System (INIS)

    Fitzgerald, R.

    2016-01-01

    Studies and calibrations of short-lived radionuclides, for example "1"5O, are of particular interest in nuclear medicine. Yet counting experiments on such species are vulnerable to an error due to the combined effect of decay and dead time. Separate decay corrections and dead-time corrections do not account for this issue. Usually counting data are decay-corrected to the start time of the count period, or else instead of correcting the count rate, the mid-time of the measurement is used as the reference time. Correction factors are derived for both those methods, considering both extending and non-extending dead time. Series approximations are derived here and the accuracy of those approximations are discussed. - Highlights: • Derived combined effects of decay and dead time. • Derived for counting systems with extending or non-extending dead times. • Derived series expansions for both midpoint and decay-to-start-time methods. • Useful for counting experiments with short-lived radionuclides. • Examples given for "1"5O, used in PET scanning.

  10. Ultra-short time sciences. From the atto-second to the peta-watts

    International Nuclear Information System (INIS)

    2000-01-01

    This book presents the recent advances in the scientific and technical domains linked with ultra-short time physics. It deals first with the conceptual and technological aspects of ultra-intense and ultra-brief lasers. Then, it describes the different domains of research (atoms, molecules and aggregates; gaseous phase dynamics using the pump-probe technique; femto-chemistry in dense phase; condensed matter; plasma physics; consistent control; aerosols; functional femto-biology) and the different domains of application (medical diagnosis; ophthalmology; telecommunications; technological and industrial developments). A last part is devoted to the teaching of ultra-short time sciences. (J.S.)

  11. Robust and Adaptive Online Time Series Prediction with Long Short-Term Memory

    Directory of Open Access Journals (Sweden)

    Haimin Yang

    2017-01-01

    Full Text Available Online time series prediction is the mainstream method in a wide range of fields, ranging from speech analysis and noise cancelation to stock market analysis. However, the data often contains many outliers with the increasing length of time series in real world. These outliers can mislead the learned model if treated as normal points in the process of prediction. To address this issue, in this paper, we propose a robust and adaptive online gradient learning method, RoAdam (Robust Adam, for long short-term memory (LSTM to predict time series with outliers. This method tunes the learning rate of the stochastic gradient algorithm adaptively in the process of prediction, which reduces the adverse effect of outliers. It tracks the relative prediction error of the loss function with a weighted average through modifying Adam, a popular stochastic gradient method algorithm for training deep neural networks. In our algorithm, the large value of the relative prediction error corresponds to a small learning rate, and vice versa. The experiments on both synthetic data and real time series show that our method achieves better performance compared to the existing methods based on LSTM.

  12. Robust and Adaptive Online Time Series Prediction with Long Short-Term Memory.

    Science.gov (United States)

    Yang, Haimin; Pan, Zhisong; Tao, Qing

    2017-01-01

    Online time series prediction is the mainstream method in a wide range of fields, ranging from speech analysis and noise cancelation to stock market analysis. However, the data often contains many outliers with the increasing length of time series in real world. These outliers can mislead the learned model if treated as normal points in the process of prediction. To address this issue, in this paper, we propose a robust and adaptive online gradient learning method, RoAdam (Robust Adam), for long short-term memory (LSTM) to predict time series with outliers. This method tunes the learning rate of the stochastic gradient algorithm adaptively in the process of prediction, which reduces the adverse effect of outliers. It tracks the relative prediction error of the loss function with a weighted average through modifying Adam, a popular stochastic gradient method algorithm for training deep neural networks. In our algorithm, the large value of the relative prediction error corresponds to a small learning rate, and vice versa. The experiments on both synthetic data and real time series show that our method achieves better performance compared to the existing methods based on LSTM.

  13. Viruses as groundwater tracers: using ecohydrology to characterize short travel times in aquifers

    Science.gov (United States)

    Hunt, Randall J.; Borchardt, Mark A.; Bradbury, Kenneth R.

    2014-01-01

    Viruses are attractive tracers of short (population over time; therefore, the virus snapshot shed in the fecal wastes of an infected population at a specific point in time can serve as a marker for tracking virus and groundwater movement. The virus tracing approach and an example application are described to illustrate their ability to characterize travel times in high-groundwater velocity settings, and provide insight unavailable from standard hydrogeologic approaches. Although characterization of preferential flowpaths does not usually characterize the majority of other travel times occurring in the groundwater system (e.g., center of plume mass; tail of the breakthrough curve), virus approaches can trace very short times of transport, and thus can fill an important gap in our current hydrogeology toolbox.

  14. Psychometric properties of the Hebrew short version of the Zimbardo Time Perspective Inventory.

    Science.gov (United States)

    Orkibi, Hod

    2015-06-01

    The purpose of this study was to develop a short Hebrew version of the Zimbardo Time Perspective Inventory that can be easily administered by health professionals in research, therapy, and counseling. First, the empirical links of time perspective (TP) to subjective well-being and health protective and health risk behaviors are reviewed. Then, a brief account of the instrument's previous modifications is provided. Results of confirmatory factor analysis (N = 572) verified the five-factor structure of the short version and yielded acceptable internal consistency reliability for each factor. The correlation coefficients between the five subscales of the short (20 items) and the original (56 items) instruments were all above .79, indicating the suitability of the short version for assessing the five TP factors. Support for the discriminant and concurrent validity was also achieved, largely in agreement with previous findings. Finally, limitations and future directions are addressed, and potential applications in therapy and counseling are offered. © The Author(s) 2014.

  15. Time-resolved measurement of the quantum states of photons using two-photon interference with short-time reference pulses

    International Nuclear Information System (INIS)

    Ren Changliang; Hofmann, Holger F.

    2011-01-01

    To fully utilize the energy-time degree of freedom of photons for optical quantum-information processes, it is necessary to control and characterize the temporal quantum states of the photons at extremely short time scales. For measurements of the temporal coherence of the quantum states beyond the time resolution of available detectors, two-photon interference with a photon in a short-time reference pulse may be a viable alternative. In this paper, we derive the temporal measurement operators for the bunching statistics of a single-photon input state with a photon from a weak coherent reference pulse. It is shown that the effects of the pulse shape of the reference pulse can be expressed in terms of a spectral filter selecting the bandwidth within which the measurement can be treated as an ideal projection on eigenstates of time. For full quantum tomography, temporal coherence can be determined by using superpositions of reference pulses at two different times. Moreover, energy-time entanglement can be evaluated based on the two-by-two entanglement observed in the coherences between pairs of detection times.

  16. Application of short-time activation analysis in the sciences

    International Nuclear Information System (INIS)

    Grass, F.

    1991-01-01

    Short-time activation analysis has proved to be a valuable tool in nearly all fields of science. To take full advantage of this technique, it is favorable to use a fast transfer system and a high resolution high rate gamma-spectroscopy system for short lived gamma-emitters and a Cherenkov detector for the determination of hard beta-emitters. It is then possible to utilize sub-minute nuclides Li-8 (740 ms), B-12 (20 ms), F-20 (11.1 s), Y-89m (16 s), and Pb-207m (800 ms) for the determination of these elements. Besides these sub-minute nuclides which constitute the only possibility for neutron activation analysis of these elements there are a number of other elements which form longer lived nuclides on short irradiation. The analysis of the halogenides F, Cl, Br, I in waste water of a sewage incineration plant can be achieved with a single 20 s irradiation and two consecutive measurement of 20 and 600 s using Cl-38m, F-20, Br-79m as well as the longer lived Cl-38, Br-80, I-128

  17. The case of escape probability as linear in short time

    Science.gov (United States)

    Marchewka, A.; Schuss, Z.

    2018-02-01

    We derive rigorously the short-time escape probability of a quantum particle from its compactly supported initial state, which has a discontinuous derivative at the boundary of the support. We show that this probability is linear in time, which seems to be a new result. The novelty of our calculation is the inclusion of the boundary layer of the propagated wave function formed outside the initial support. This result has applications to the decay law of the particle, to the Zeno behaviour, quantum absorption, time of arrival, quantum measurements, and more.

  18. The short time Fourier transform and local signals

    Science.gov (United States)

    Okumura, Shuhei

    In this thesis, I examine the theoretical properties of the short time discrete Fourier transform (STFT). The STFT is obtained by applying the Fourier transform by a fixed-sized, moving window to input series. We move the window by one time point at a time, so we have overlapping windows. I present several theoretical properties of the STFT, applied to various types of complex-valued, univariate time series inputs, and their outputs in closed forms. In particular, just like the discrete Fourier transform, the STFT's modulus time series takes large positive values when the input is a periodic signal. One main point is that a white noise time series input results in the STFT output being a complex-valued stationary time series and we can derive the time and time-frequency dependency structure such as the cross-covariance functions. Our primary focus is the detection of local periodic signals. I present a method to detect local signals by computing the probability that the squared modulus STFT time series has consecutive large values exceeding some threshold after one exceeding observation following one observation less than the threshold. We discuss a method to reduce the computation of such probabilities by the Box-Cox transformation and the delta method, and show that it works well in comparison to the Monte Carlo simulation method.

  19. Short time ahead wind power production forecast

    International Nuclear Information System (INIS)

    Sapronova, Alla; Meissner, Catherine; Mana, Matteo

    2016-01-01

    An accurate prediction of wind power output is crucial for efficient coordination of cooperative energy production from different sources. Long-time ahead prediction (from 6 to 24 hours) of wind power for onshore parks can be achieved by using a coupled model that would bridge the mesoscale weather prediction data and computational fluid dynamics. When a forecast for shorter time horizon (less than one hour ahead) is anticipated, an accuracy of a predictive model that utilizes hourly weather data is decreasing. That is because the higher frequency fluctuations of the wind speed are lost when data is averaged over an hour. Since the wind speed can vary up to 50% in magnitude over a period of 5 minutes, the higher frequency variations of wind speed and direction have to be taken into account for an accurate short-term ahead energy production forecast. In this work a new model for wind power production forecast 5- to 30-minutes ahead is presented. The model is based on machine learning techniques and categorization approach and using the historical park production time series and hourly numerical weather forecast. (paper)

  20. Short time ahead wind power production forecast

    Science.gov (United States)

    Sapronova, Alla; Meissner, Catherine; Mana, Matteo

    2016-09-01

    An accurate prediction of wind power output is crucial for efficient coordination of cooperative energy production from different sources. Long-time ahead prediction (from 6 to 24 hours) of wind power for onshore parks can be achieved by using a coupled model that would bridge the mesoscale weather prediction data and computational fluid dynamics. When a forecast for shorter time horizon (less than one hour ahead) is anticipated, an accuracy of a predictive model that utilizes hourly weather data is decreasing. That is because the higher frequency fluctuations of the wind speed are lost when data is averaged over an hour. Since the wind speed can vary up to 50% in magnitude over a period of 5 minutes, the higher frequency variations of wind speed and direction have to be taken into account for an accurate short-term ahead energy production forecast. In this work a new model for wind power production forecast 5- to 30-minutes ahead is presented. The model is based on machine learning techniques and categorization approach and using the historical park production time series and hourly numerical weather forecast.

  1. Adaptive synchrosqueezing based on a quilted short-time Fourier transform

    Science.gov (United States)

    Berrian, Alexander; Saito, Naoki

    2017-08-01

    In recent years, the synchrosqueezing transform (SST) has gained popularity as a method for the analysis of signals that can be broken down into multiple components determined by instantaneous amplitudes and phases. One such version of SST, based on the short-time Fourier transform (STFT), enables the sharpening of instantaneous frequency (IF) information derived from the STFT, as well as the separation of amplitude-phase components corresponding to distinct IF curves. However, this SST is limited by the time-frequency resolution of the underlying window function, and may not resolve signals exhibiting diverse time-frequency behaviors with sufficient accuracy. In this work, we develop a framework for an SST based on a "quilted" short-time Fourier transform (SST-QSTFT), which allows adaptation to signal behavior in separate time-frequency regions through the use of multiple windows. This motivates us to introduce a discrete reassignment frequency formula based on a finite difference of the phase spectrum, ensuring computational accuracy for a wider variety of windows. We develop a theoretical framework for the SST-QSTFT in both the continuous and the discrete settings, and describe an algorithm for the automatic selection of optimal windows depending on the region of interest. Using synthetic data, we demonstrate the superior numerical performance of SST-QSTFT relative to other SST methods in a noisy context. Finally, we apply SST-QSTFT to audio recordings of animal calls to demonstrate the potential of our method for the analysis of real bioacoustic signals.

  2. GenHtr: a tool for comparative assessment of genetic heterogeneity in microbial genomes generated by massive short-read sequencing

    Directory of Open Access Journals (Sweden)

    Yu GongXin

    2010-10-01

    Full Text Available Abstract Background Microevolution is the study of short-term changes of alleles within a population and their effects on the phenotype of organisms. The result of the below-species-level evolution is heterogeneity, where populations consist of subpopulations with a large number of structural variations. Heterogeneity analysis is thus essential to our understanding of how selective and neutral forces shape bacterial populations over a short period of time. The Solexa Genome Analyzer, a next-generation sequencing platform, allows millions of short sequencing reads to be obtained with great accuracy, allowing for the ability to study the dynamics of the bacterial population at the whole genome level. The tool referred to as GenHtr was developed for genome-wide heterogeneity analysis. Results For particular bacterial strains, GenHtr relies on a set of Solexa short reads on given bacteria pathogens and their isogenic reference genome to identify heterogeneity sites, the chromosomal positions with multiple variants of genes in the bacterial population, and variations that occur in large gene families. GenHtr accomplishes this by building and comparatively analyzing genome-wide heterogeneity genotypes for both the newly sequenced genomes (using massive short-read sequencing and their isogenic reference (using simulated data. As proof of the concept, this approach was applied to SRX007711, the Solexa sequencing data for a newly sequenced Staphylococcus aureus subsp. USA300 cell line, and demonstrated that it could predict such multiple variants. They include multiple variants of genes critical in pathogenesis, e.g. genes encoding a LysR family transcriptional regulator, 23 S ribosomal RNA, and DNA mismatch repair protein MutS. The heterogeneity results in non-synonymous and nonsense mutations, leading to truncated proteins for both LysR and MutS. Conclusion GenHtr was developed for genome-wide heterogeneity analysis. Although it is much more time

  3. Improved Multiscale Entropy Technique with Nearest-Neighbor Moving-Average Kernel for Nonlinear and Nonstationary Short-Time Biomedical Signal Analysis

    Directory of Open Access Journals (Sweden)

    S. P. Arunachalam

    2018-01-01

    Full Text Available Analysis of biomedical signals can yield invaluable information for prognosis, diagnosis, therapy evaluation, risk assessment, and disease prevention which is often recorded as short time series data that challenges existing complexity classification algorithms such as Shannon entropy (SE and other techniques. The purpose of this study was to improve previously developed multiscale entropy (MSE technique by incorporating nearest-neighbor moving-average kernel, which can be used for analysis of nonlinear and non-stationary short time series physiological data. The approach was tested for robustness with respect to noise analysis using simulated sinusoidal and ECG waveforms. Feasibility of MSE to discriminate between normal sinus rhythm (NSR and atrial fibrillation (AF was tested on a single-lead ECG. In addition, the MSE algorithm was applied to identify pivot points of rotors that were induced in ex vivo isolated rabbit hearts. The improved MSE technique robustly estimated the complexity of the signal compared to that of SE with various noises, discriminated NSR and AF on single-lead ECG, and precisely identified the pivot points of ex vivo rotors by providing better contrast between the rotor core and the peripheral region. The improved MSE technique can provide efficient complexity analysis of variety of nonlinear and nonstationary short-time biomedical signals.

  4. The role of short-time intensity and envelope power for speech intelligibility and psychoacoustic masking.

    Science.gov (United States)

    Biberger, Thomas; Ewert, Stephan D

    2017-08-01

    The generalized power spectrum model [GPSM; Biberger and Ewert (2016). J. Acoust. Soc. Am. 140, 1023-1038], combining the "classical" concept of the power-spectrum model (PSM) and the envelope power spectrum-model (EPSM), was demonstrated to account for several psychoacoustic and speech intelligibility (SI) experiments. The PSM path of the model uses long-time power signal-to-noise ratios (SNRs), while the EPSM path uses short-time envelope power SNRs. A systematic comparison of existing SI models for several spectro-temporal manipulations of speech maskers and gender combinations of target and masker speakers [Schubotz et al. (2016). J. Acoust. Soc. Am. 140, 524-540] showed the importance of short-time power features. Conversely, Jørgensen et al. [(2013). J. Acoust. Soc. Am. 134, 436-446] demonstrated a higher predictive power of short-time envelope power SNRs than power SNRs using reverberation and spectral subtraction. Here the GPSM was extended to utilize short-time power SNRs and was shown to account for all psychoacoustic and SI data of the three mentioned studies. The best processing strategy was to exclusively use either power or envelope-power SNRs, depending on the experimental task. By analyzing both domains, the suggested model might provide a useful tool for clarifying the contribution of amplitude modulation masking and energetic masking.

  5. Short irradiation time characteristics of the inverter type X-ray generator

    International Nuclear Information System (INIS)

    Miyazaki, Shigeru; Hara, Takamitu; Matutani, Kazuo; Saito, Kazuhiko.

    1994-01-01

    The linearity of the X-ray output is an important factor in radiography. It is a composite of the linearities of the X-ray tube voltage, the X-ray tube current, and the exposure time. This paper focuses on the linearity of exposure time. Non-linearity of the X-ray output for short-time exposure became a problem when the three-phase X-ray generator was introduced. This paper describes the inverter-type X-ray generator, which is expected to become predominant in the future. Previously, we investigated X-ray output linearity during short-time exposure using the technique of dynamic study. In this paper, we describe the application of a digital memory and a personal computer to further investigation. The non-linearity of the X-ray output was caused by irregular waveforms of the X-ray tube voltage found at the rise time and the fall time. When the rise time was about 0.6 ms, the non-linearity was about 2%, which is negligibly small. The non-linearity due to the fall time of the X-ray tube varied greatly according to the X-ray tube current. For the minimum irradiation time of 1 ms, 4% to 27% of the non-linearity was attributable to the fall time. The main cause was the stray capacitance of the X-ray high-voltage cables. When the X-ray tube current exceeded 400 mA, the rise time was almost equal to the fall time, and the problem did not occur. Consequently, the ideal generator should have a fall time which is equal to the rise time of the X-ray tube voltage. Strictly speaking, such a generator should have rectangular waveforms. (author)

  6. Modular High Voltage Pulse Converter for Short Rise and Decay Times

    NARCIS (Netherlands)

    Mao, S.

    2018-01-01

    This thesis explores a modular HV pulse converter technology with short rise and decay times. A systematic methodology to derive and classify HV architectures based on a modularization level of power building blocks of the HV pulse converter is developed to summarize existing architectures and

  7. Eulerian short-time statistics of turbulent flow at large Reynolds number

    NARCIS (Netherlands)

    Brouwers, J.J.H.

    2004-01-01

    An asymptotic analysis is presented of the short-time behavior of second-order temporal velocity structure functions and Eulerian acceleration correlations in a frame that moves with the local mean velocity of the turbulent flow field. Expressions in closed-form are derived which cover the viscous

  8. Rotor-System Log-Decrement Identification Using Short-Time Fourier-Transform Filter

    OpenAIRE

    Li, Qihang; Wang, Weimin; Chen, Lifang; Sun, Dan

    2015-01-01

    With the increase of the centrifugal compressor capability, such as large scale LNG and CO2 reinjection, the stability margin evaluation is crucial to assure the compressor work in the designed operating conditions in field. Improving the precision of parameter identification of stability is essential and necessary as well. Based on the time-varying characteristics of response vibration during the sine-swept process, a short-time Fourier transform (STFT) filter was introduced to increase the ...

  9. Measurement and deconvolution of detector response time for short HPM pulses: Part 1, Microwave diodes

    International Nuclear Information System (INIS)

    Bolton, P.R.

    1987-06-01

    A technique is described for measuring and deconvolving response times of microwave diode detection systems in order to generate corrected input signals typical of an infinite detection rate. The method has been applied to cases of 2.86 GHz ultra-short HPM pulse detection where pulse rise time is comparable to that of the detector; whereas, the duration of a few nanoseconds is significantly longer. Results are specified in terms of the enhancement of equivalent deconvolved input voltages for given observed voltages. The convolution integral imposes the constraint of linear detector response to input power levels. This is physically equivalent to the conservation of integrated pulse energy in the deconvolution process. The applicable dynamic range of a microwave diode is therefore limited to a smaller signal region as determined by its calibration

  10. Sublethal effects of the herbicide glufosinate ammonium on crops and wild plants: short-term effects compared to vegetative recovery and plant reproduction.

    Science.gov (United States)

    Carpenter, David; Boutin, Céline

    2010-10-01

    Current guidelines for phytotoxicity testing rely heavily on short-term testing of primarily crop species to predict the sensitivity of non-target, wild plants to herbicides. However, little is known on how plants recover following initial growth inhibitions in standard 14-28 day greenhouse tests conducted for pesticide assessment and registration. The objectives of this study were to assess the ability of plant species to recover (biomass and reproduction) when tested at the juvenile stage (routine regulatory testing), comparing crop and wild species and using the herbicide glufosinate ammonium. Ten crops and 10 wild species were tested with a one-time exposure to glufosinate ammonium in a greenhouse. Half the plants of each species (9 doses × 6 replicates) were harvested 3 weeks after being sprayed (short-term). The remaining plants were harvested several weeks later, coinciding with seed set or natural senescence (long-term). Total aboveground biomass and several endpoints related to crop production and plant reproduction were measured. Calculated IC50 values (dosage that results in a 50% decrease in the biomass of a plant as compared to the untreated controls) based solely on aboveground biomass, for species harvested in the long-term were generally higher than those obtained in the short-term (with two exceptions), indicating recovery over time. Crop species did not differ from wild species in terms of sensitivity. However, in seven out of 12 cases where reproduction was measurable, reproductive endpoints were more sensitive than either short or long-term biomass endpoints, indicating the importance of examining these parameters in phytotoxicity testing. Glufosinate ammonium was found to be phytotoxic at low doses (2.64-7.74% g ai/ha of the label rate).

  11. Gene expression profiling of canine osteosarcoma reveals genes associated with short and long survival times

    Directory of Open Access Journals (Sweden)

    Rao Nagesha AS

    2009-09-01

    Full Text Available Abstract Background Gene expression profiling of spontaneous tumors in the dog offers a unique translational opportunity to identify prognostic biomarkers and signaling pathways that are common to both canine and human. Osteosarcoma (OS accounts for approximately 80% of all malignant bone tumors in the dog. Canine OS are highly comparable with their human counterpart with respect to histology, high metastatic rate and poor long-term survival. This study investigates the prognostic gene profile among thirty-two primary canine OS using canine specific cDNA microarrays representing 20,313 genes to identify genes and cellular signaling pathways associated with survival. This, the first report of its kind in dogs with OS, also demonstrates the advantages of cross-species comparison with human OS. Results The 32 tumors were classified into two prognostic groups based on survival time (ST. They were defined as short survivors (dogs with poor prognosis: surviving fewer than 6 months and long survivors (dogs with better prognosis: surviving 6 months or longer. Fifty-one transcripts were found to be differentially expressed, with common upregulation of these genes in the short survivors. The overexpressed genes in short survivors are associated with possible roles in proliferation, drug resistance or metastasis. Several deregulated pathways identified in the present study, including Wnt signaling, Integrin signaling and Chemokine/cytokine signaling are comparable to the pathway analysis conducted on human OS gene profiles, emphasizing the value of the dog as an excellent model for humans. Conclusion A molecular-based method for discrimination of outcome for short and long survivors is useful for future prognostic stratification at initial diagnosis, where genes and pathways associated with cell cycle/proliferation, drug resistance and metastasis could be potential targets for diagnosis and therapy. The similarities between human and canine OS makes the

  12. Short-term memory loss over time without retroactive stimulus interference.

    Science.gov (United States)

    Cowan, Nelson; AuBuchon, Angela M

    2008-02-01

    A key question in cognitive psychology is whether information in short-term memory is lost as a function of time. Lewandowsky, Duncan, and Brown (2004) argued against that memory loss because forgetting in serial recall occurred to the same extent across serial positions regardless of the rate of recall. However, we believe Lewandowsky et al. (2004) only prevented one of two types of rehearsal; they did not prevent nonarticulatory rehearsal via attention. To prevent articulatory and nonarticulatory rehearsal without introducing interference, we presented unevenly timed stimuli for serial recall and, on some trials, required that the timing of stimuli be reproduced in the response. In those trials only, evidence of memory loss over time emerged. Further research is needed to identify whether this memory loss is decay or lost distinctiveness.

  13. Musicians' and nonmusicians' short-term memory for verbal and musical sequences: comparing phonological similarity and pitch proximity.

    Science.gov (United States)

    Williamson, Victoria J; Baddeley, Alan D; Hitch, Graham J

    2010-03-01

    Language-music comparative studies have highlighted the potential for shared resources or neural overlap in auditory short-term memory. However, there is a lack of behavioral methodologies for comparing verbal and musical serial recall. We developed a visual grid response that allowed both musicians and nonmusicians to perform serial recall of letter and tone sequences. The new method was used to compare the phonological similarity effect with the impact of an operationalized musical equivalent-pitch proximity. Over the course of three experiments, we found that short-term memory for tones had several similarities to verbal memory, including limited capacity and a significant effect of pitch proximity in nonmusicians. Despite being vulnerable to phonological similarity when recalling letters, however, musicians showed no effect of pitch proximity, a result that we suggest might reflect strategy differences. Overall, the findings support a limited degree of correspondence in the way that verbal and musical sounds are processed in auditory short-term memory.

  14. Quantum Dynamics with Short-Time Trajectories and Minimal Adaptive Basis Sets.

    Science.gov (United States)

    Saller, Maximilian A C; Habershon, Scott

    2017-07-11

    Methods for solving the time-dependent Schrödinger equation via basis set expansion of the wave function can generally be categorized as having either static (time-independent) or dynamic (time-dependent) basis functions. We have recently introduced an alternative simulation approach which represents a middle road between these two extremes, employing dynamic (classical-like) trajectories to create a static basis set of Gaussian wavepackets in regions of phase-space relevant to future propagation of the wave function [J. Chem. Theory Comput., 11, 8 (2015)]. Here, we propose and test a modification of our methodology which aims to reduce the size of basis sets generated in our original scheme. In particular, we employ short-time classical trajectories to continuously generate new basis functions for short-time quantum propagation of the wave function; to avoid the continued growth of the basis set describing the time-dependent wave function, we employ Matching Pursuit to periodically minimize the number of basis functions required to accurately describe the wave function. Overall, this approach generates a basis set which is adapted to evolution of the wave function while also being as small as possible. In applications to challenging benchmark problems, namely a 4-dimensional model of photoexcited pyrazine and three different double-well tunnelling problems, we find that our new scheme enables accurate wave function propagation with basis sets which are around an order-of-magnitude smaller than our original trajectory-guided basis set methodology, highlighting the benefits of adaptive strategies for wave function propagation.

  15. Thermonuclear Bursts with Short Recurrence Times from Neutron Stars Explained by Opacity-driven Convection

    Energy Technology Data Exchange (ETDEWEB)

    Keek, L. [X-ray Astrophysics Laboratory, Astrophysics Science Division, NASA/GSFC, Greenbelt, MD 20771 (United States); Heger, A., E-mail: laurens.keek@nasa.gov [Monash Center for Astrophysics, School of Physics and Astronomy, Monash University, Victoria, 3800 (Australia)

    2017-06-20

    Thermonuclear flashes of hydrogen and helium accreted onto neutron stars produce the frequently observed Type I X-ray bursts. It is the current paradigm that almost all material burns in a burst, after which it takes hours to accumulate fresh fuel for the next burst. In rare cases, however, bursts are observed with recurrence times as short as minutes. We present the first one-dimensional multi-zone simulations that reproduce this phenomenon. Bursts that ignite in a relatively hot neutron star envelope leave a substantial fraction of the fuel unburned at shallow depths. In the wake of the burst, convective mixing events driven by opacity bring this fuel down to the ignition depth on the observed timescale of minutes. There, unburned hydrogen mixes with the metal-rich ashes, igniting to produce a subsequent burst. We find burst pairs and triplets, similar to the observed instances. Our simulations reproduce the observed fraction of bursts with short waiting times of ∼30%, and demonstrate that short recurrence time bursts are typically less bright and of shorter duration.

  16. Short-time existence of solutions for mean-field games with congestion

    KAUST Repository

    Gomes, Diogo A.

    2015-11-20

    We consider time-dependent mean-field games with congestion that are given by a Hamilton–Jacobi equation coupled with a Fokker–Planck equation. These models are motivated by crowd dynamics in which agents have difficulty moving in high-density areas. The congestion effects make the Hamilton–Jacobi equation singular. The uniqueness of solutions for this problem is well understood; however, the existence of classical solutions was only known in very special cases, stationary problems with quadratic Hamiltonians and some time-dependent explicit examples. Here, we demonstrate the short-time existence of C∞ solutions for sub-quadratic Hamiltonians.

  17. Time-frequency analysis of fusion plasma signals beyond the short-time Fourier transform paradigm: An overview

    International Nuclear Information System (INIS)

    Bizarro, Joao P.S.; Figueiredo, Antonio C.A.

    2008-01-01

    Performing a time-frequency (t-f) analysis on actual magnetic pick-up coil data from the JET tokamak, a comparison is presented between the spectrogram and the Wigner and Choi-Williams distributions. Whereas the former, which stems from the short-time Fourier transform and has been the work-horse for t-f signal processing, implies an unavoidable trade-off between time and frequency resolutions, the latter two belong to a later generation of distributions that yield better, if not optimal joint t-f localization. Topics addressed include signal representation in the t-f plane, frequency identification and evolution, instantaneous-frequency estimation, and amplitude tracking

  18. On the applicability of short time measurements to the determination of annual average of radon concentration in dwelling

    International Nuclear Information System (INIS)

    Loskiewicz, J.; Olko, P.; Swakon, J.; Bogacz, J.; Janik, M.; Mazur, D.; Mazur, J.

    1998-01-01

    The variation of radon concentration in some houses in the Krakow region was investigated in order to compare results obtained using various measuring techniques. It is concluded that short-term measurements should last at least 4 days to avoid errors exceeding 30%; that weather parameters and human activity during the measurement should be recorded; that measurements should be repeated several times under various weather conditions; that seasonal variation in the region should be taken into account. (A.K.)

  19. [Clinical characteristics of short tear film breakup time (BUT) -type dry eye].

    Science.gov (United States)

    Yamamoto, Yuji; Yokoi, Norihiko; Higashihara, Hisayo; Inagaki, Kayoko; Sonomura, Yukiko; Komuro, Aoi; Kinoshita, Shigeru

    2012-12-01

    To evaluate the clinical characteristics and management of short tear film breakup time (BUT) -type dry eye. Clinical background and post-treatment changes of symptoms in 77 patients with short BUT -type dry eye were investigated. Treatment consisted of artificial-tear eye-drop instillation and, if necessary, the addition of a low-density-level steroid, hyaluronic acid, a low-density-level cyclopentolate prepared by ourselves and punctal plugs inserted into the upper and lower lacrimal puncta. There were three times more women than men among the patients, and the peak age of occurrence was in the twenties in the men and in the sixties in the women. Our findings show that visual display terminal (VDT) work, contact lens (CL) wear, and changes in the sex hormones may initiate subjective symptoms. Some patients had simultaneous conjunctivochalasis, allergic conjunctivitis, and meibomian gland dysfunction. Nineteen patients (24.7%) were effectively treated with eye-drop instillation alone. Thirty-seven patients (48.1%) required punctal-plug insertion, which was completely effective in only 8 of them (21.6%). Mainly young men and menopausal women contract short BUT -type dry eye. Changes in sex hormones, VDT work and CL wear may be causal, and the disease cannot be controlled by eyedrop and punctal-plug treatment alone.

  20. EVOLVING TO TYPE Ia SUPERNOVAE WITH SHORT DELAY TIMES

    International Nuclear Information System (INIS)

    Wang Bo; Chen Xuefei; Han Zhanwen; Meng Xiangcun

    2009-01-01

    The single-degenerate model is currently a favorable progenitor model for Type Ia supernovae (SNe Ia). Recent investigations on the white dwarf (WD) + He star channel of the single-degenerate model imply that this channel is noteworthy for producing SNe Ia. In this paper, we studied SN Ia birthrates and delay times of this channel via a detailed binary population synthesis approach. We found that the Galactic SN Ia birthrate from the WD + He star channel is ∼0.3 x 10 -3 yr -1 according to our standard model, and that this channel can explain SNe Ia with short delay times (∼4.5 x 10 7 -1.4 x 10 8 yr). Meanwhile, these WD + He star systems may be related to the young supersoft X-ray sources prior to SN Ia explosions.

  1. Short-term fluctuations in bivalve larvae compared with some environmental factors in a coastal lagoon (South Portugal

    Directory of Open Access Journals (Sweden)

    Luis M.Z. Chícaro

    2000-12-01

    Full Text Available In this study, short-term fluctuations in bivalve larvae were compared with some triggering factors for a period of sixteen months. Data on the abundance of planktonic larvae, collected two to three times a week were related to water temperature, salinity, wind velocity, tidal amplitude and chlorophyll a. Higher densities of planktonic bivalve larvae were caught between May and August, but intense fluctuations in abundance were observed. Planktonic bivalve larvae of eighteen taxa were identified. Larvae of Mytilus galloprovincialis, Cerastoderma edule, Ruditapes decussates and Venerupis spp. were the most abundant. The seasonal fluctuations of bivalve abundance seem to be controlled by temperature, the major factor in the timing of the reproduction of bivalves. Nevertheless, advection may be also a key factor during the planktonic life of bivalve species in coastal systems, such as the Ria Formosa.

  2. Enhanced short-term sensitization of facial compared with limb heat pain.

    Science.gov (United States)

    Schmidt, Katharina; Schunke, Odette; Forkmann, Katarina; Bingel, Ulrike

    2015-08-01

    Habituation and sensitization are important features of individual sensitivity to repetitive noxious stimulation and have been investigated in numerous studies. However, it is unclear whether these phenomena vary depending on the site of stimulation. Here we compared short-term and long-term effects of painful heat stimulation on the forehead and limb using an established longitudinal heat pain paradigm performed over 8 consecutive days in 36 healthy volunteers. Participants were randomized into 2 groups; participants received repetitive heat pain stimulation either on the left volar forearm or on the left side of the forehead. Our data show a comparable degree of habituation over the course of 8 days in both groups. However, participants in the trigeminal stimulation group exhibited stronger within-session sensitization (indexed by a higher within-session increase in pain intensity ratings) than those who received the forearm stimulation. Furthermore, over the course of the experiment we found a correlation between habituation and anxiety, showing less habituation in participants with higher trait anxiety scores. Our findings are in line with somatotopic differences in response to painful stimulation and a higher proneness of trigeminal pain to sensitization processes, which might be explained by the biological relevance of the head and facial area for vital functions. The contribution of this sensitivity to the development and maintenance of clinical facial pain and headache disorders warrants further investigation. This study uses psychophysical methods to evaluate the differences in long-term habituation and short-term sensitization to heat pain between the trigeminal and spinal systems. We found stronger sensitization for trigeminal compared with nociceptive stimuli on the forearm. The contribution of this sensitivity to clinical pain states warrants further investigation. Copyright © 2015 American Pain Society. Published by Elsevier Inc. All rights reserved.

  3. NMR transmit-receive system with short recovery time and effective isolation

    Science.gov (United States)

    Jurga, K.; Reynhardt, E. C.; Jurga, S.

    A transmit-receive system with a short recovery time and excellent isolation has been developed. The system operates in conjunction with an ENI Model 3200L broadband amplifier and a spin-lock NMR pulse spectrometer. The system has been tested in the frequency range 5.5 to 52 MHz and seems not to generate any background noise.

  4. A comparative study of the therapeutic effect between long and short intramedullary nails in the treatment of intertrochanteric femur fractures in the elderly.

    Science.gov (United States)

    Guo, Xue-Feng; Zhang, Ke-Ming; Fu, Hong-Bo; Cao, Wen; Dong, Qiang

    2015-01-01

    To compare the clinical effects of long vs. short intramedullary nails in the treatment of intertrochanteric fractures in old patients more than 65 years old. A retrospective analysis of 178 cases of intertrochanteric fractures of the femur (AO type A1 and A2) in the elderly was conducted from January 2008 to December 2013. There were 85 males (47.8%) and 93 females (52.2%) with the age of 65e89 (70.2±10.8) years. The patients were treated by closed reduction and long or short intramedullary nail (Gamma 3) fixation. The length of short nail was 180 mm and that for long nail was 320e360 mm. The general data of patients, operation time, intraoperative blood loss, length of hospital stay, preoperative hemoglobin level, blood transfusion rate, postoperative periprosthetic fractures, infections, complications, etc were carefully recorded. There were 76 cases (42.7%) in the long intramedullary nail group and 102 cases (57.3%) in the short nail group. All the cases were followed up for 12e48 (21.3±6.8) months, during which there were 21 deaths (11.8%), mean (13.8±6.9) months after operation. The intraoperative blood loss was (90.7±50.6) ml in short nail group, greatly less than that in long nail group (127.8±85.9) ml (p=0.004). The short nail group also had a significantly shorter operation time (43.5 min±12.3 min vs. 58.5 min±20.3 min, p=0.002) and lower rate of postoperative transfusion (42.3% vs. 56.7%, p=0.041). But the length of hospital stay showed no big differences. After operation, in each group there was 1 case of periprosthetic fracture with a total incidence of 1.1%, 1.3% in long nail group and 0.9% in short nail group. At the end of the follow-up, all patients achieved bony union. The average healing time of the long nail group was (6.5±3.1) months, and the short nail group was (6.8±3.7) months, revealing no significant differences (p=0.09). Postoperative complications showed no great differences either. Both the intramedullary long and short nail

  5. Determination of rail wear and short-time wear measurements of rails applying radioisotopes

    International Nuclear Information System (INIS)

    Grohmann, H.D.

    1981-01-01

    An energetic model has been developed for calculating rail wear. Short-time wear tests on rails after surface activation and following activity measurements showed a good agreement with the calculated values

  6. Short-term adaptations as a response to travel time: results of a stated adaptation experimentincreases

    NARCIS (Netherlands)

    Psarra, I.; Arentze, T.A.; Timmermans, H.J.P.

    2016-01-01

    This study focused on short-term dynamics of activity-travel behavior as a response to travel time increases. It is assumed that short-term changes are triggered by stress, which is defined as the deviation between an individual’s aspirations and his or her daily experiences. When stress exceeds a

  7. The impact of short night-time naps on performance, sleepiness and mood during a simulated night shift.

    Science.gov (United States)

    Centofanti, Stephanie A; Hilditch, Cassie J; Dorrian, Jillian; Banks, Siobhan

    2016-01-01

    Short naps on night shift are recommended in some industries. There is a paucity of evidence to verify the sustained recovery benefits of short naps in the last few hours of the night shift. Therefore, the current study aimed to investigate the sustained recovery benefits of 30 and 10-min nap opportunities during a simulated night shift. Thirty-one healthy participants (18F, 21-35 y) completed a 3-day, between-groups laboratory study with one baseline night (22:00-07:00 h time in bed), followed by one night awake (time awake from 07:00 h on day two through 10:00 h day three) with random allocation to: a 10-min nap opportunity ending at 04:00 h, a 30-min nap opportunity ending at 04:00 h or no nap (control). A neurobehavioral test bout was administered approximately every 2 h during wake periods. There were no significant differences between nap conditions for post-nap psychomotor vigilance performance after controlling for pre-nap scores (p > 0.05). The 30-min nap significantly improved subjective sleepiness compared to the 10-min nap and no-nap control (p effect.

  8. Short-term wind power forecasting: probabilistic and space-time aspects

    DEFF Research Database (Denmark)

    Tastu, Julija

    work deals with the proposal and evaluation of new mathematical models and forecasting methods for short-term wind power forecasting, accounting for space-time dynamics based on geographically distributed information. Different forms of power predictions are considered, starting from traditional point...... into the corresponding models are analysed. As a final step, emphasis is placed on generating space-time trajectories: this calls for the prediction of joint multivariate predictive densities describing wind power generation at a number of distributed locations and for a number of successive lead times. In addition......Optimal integration of wind energy into power systems calls for high quality wind power predictions. State-of-the-art forecasting systems typically provide forecasts for every location individually, without taking into account information coming from the neighbouring territories. It is however...

  9. Short-Term Change Detection in Wetlands Using Sentinel-1 Time Series

    DEFF Research Database (Denmark)

    Muro, Javier; Canty, Morton; Conradsen, Knut

    2016-01-01

    Automated monitoring systems that can capture wetlands’ high spatial and temporal variability are essential for their management. SAR-based change detection approaches offer a great opportunity to enhance our understanding of complex and dynamic ecosystems. We test a recently-developed time serie...... certain landscape changes are detected only by either the Landsat-based or the S1-omnibus method. The S1-omnibus method shows a great potential for an automated monitoring of short time changes and accurate delineation of areas of high variability and of slow and gradual changes....

  10. Short-Term Memory Loss Over Time Without Retroactive Stimulus Interference

    OpenAIRE

    Cowan, Nelson; AuBuchon, Angela M.

    2008-01-01

    A key question in cognitive psychology is whether information in short-term memory is lost as a function of time. Lewandowsky, Duncan, and Brown (2004) argued against that memory loss because forgetting in serial recall occurred to the same extent across serial positions regardless of the rate of recall. However, we believe Lewandowsky et al. only prevented one of two types of rehearsal; they did not prevent non-articulatory rehearsal via attention. To prevent articulatory and non-articulator...

  11. Kālacakra: Shortlies Considerations on Time

    Directory of Open Access Journals (Sweden)

    Adrián Muñoz

    2013-05-01

    Full Text Available This paper calls for a comparative reading of both the Buddhist conception of time and a branch of Western phenomenology. With special emphasis on the Madhyamaka Buddhist school, it discusses the way in which fugacity and impermanence are similarly discussed by French philosopher Gaston Bachelard in his L’intuition de l’instant. In both cases, the stress lies on the fact that duration is but a mental construct lacking true, absolute reality, while at the same time the human being is subjected to hopes of transcendence which, in turn, engender disillusion and delusion.

  12. X-ray testing for short-time dynamic applications; Roentgenuntersuchungen fuer kurzzeitdynamische Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Kurfiss, Malte; Moser, Stefan; Popko, Gregor; Nau, Siegfried [Fraunhofer-Institut fuer Kurzzeitdynamik, Efringen-Kirchen (Germany). Ernst-Mach-Inst. (EMI)

    2017-08-01

    For nondestructive testing purposes new challenges are short-time dynamic processes. The application of x-ray flash tubes and modern high-speed cameras allows the observation of the opening of air-bags or the energy absorption of compressed tubes as occurring during a vehicle crash. Special algorithms designed for computerized tomography analyses allow the 3D reconstruction at individual time points of the dynamic process. Possibilities and limitations of the actual techniques are discussed.

  13. FREQUENCY COMPONENT EXTRACTION OF HEARTBEAT CUES WITH SHORT TIME FOURIER TRANSFORM (STFT

    Directory of Open Access Journals (Sweden)

    Sumarna Sumarna

    2017-01-01

      Electro-acoustic human heartbeat detector have been made with the main parts : (a stetoscope (piece chest, (b mic condenser, (c transistor amplifier, and (d cues analysis program with MATLAB. The frequency components that contained in heartbeat. cues have also been extracted with Short Time Fourier Transform (STFT from 9 volunteers. The results of the analysis showed that heart rate appeared in every cue frequency spectrum with their harmony. The steps of the research were including detector instrument design, test and instrument repair, cues heartbeat recording with Sound Forge 10 program and stored in wav file ; cues breaking at the start and the end, and extraction/cues analysis using MATLAB. The MATLAB program included filter (bandpass filter with bandwidth between 0.01 – 110 Hz, cues breaking with hamming window and every part was calculated using Fourier Transform (STFT mechanism and the result were shown in frequency spectrum graph.   Keywords: frequency components extraction, heartbeat cues, Short Time Fourier Transform

  14. Effective description of the short-time dynamics in open quantum systems

    Science.gov (United States)

    Rossi, Matteo A. C.; Foti, Caterina; Cuccoli, Alessandro; Trapani, Jacopo; Verrucchi, Paola; Paris, Matteo G. A.

    2017-09-01

    We address the dynamics of a bosonic system coupled to either a bosonic or a magnetic environment and derive a set of sufficient conditions that allow one to describe the dynamics in terms of the effective interaction with a classical fluctuating field. We find that for short interaction times the dynamics of the open system is described by a Gaussian noise map for several different interaction models and independently on the temperature of the environment. In order to go beyond a qualitative understanding of the origin and physical meaning of the above short-time constraint, we take a general viewpoint and, based on an algebraic approach, suggest that any quantum environment can be described by classical fields whenever global symmetries lead to the definition of environmental operators that remain well defined when increasing the size, i.e., the number of dynamical variables, of the environment. In the case of the bosonic environment this statement is exactly demonstrated via a constructive procedure that explicitly shows why a large number of environmental dynamical variables and, necessarily, global symmetries, entail the set of conditions derived in the first part of the work.

  15. Micro-Doppler Ambiguity Resolution Based on Short-Time Compressed Sensing

    Directory of Open Access Journals (Sweden)

    Jing-bo Zhuang

    2015-01-01

    Full Text Available When using a long range radar (LRR to track a target with micromotion, the micro-Doppler embodied in the radar echoes may suffer from ambiguity problem. In this paper, we propose a novel method based on compressed sensing (CS to solve micro-Doppler ambiguity. According to the RIP requirement, a sparse probing pulse train with its transmitting time random is designed. After matched filtering, the slow-time echo signals of the micromotion target can be viewed as randomly sparse sampling of Doppler spectrum. Select several successive pulses to form a short-time window and the CS sensing matrix can be built according to the time stamps of these pulses. Then performing Orthogonal Matching Pursuit (OMP, the unambiguous micro-Doppler spectrum can be obtained. The proposed algorithm is verified using the echo signals generated according to the theoretical model and the signals with micro-Doppler signature produced using the commercial electromagnetic simulation software FEKO.

  16. Multi-time-scale heat transfer modeling of turbid tissues exposed to short-pulsed irradiations.

    Science.gov (United States)

    Kim, Kyunghan; Guo, Zhixiong

    2007-05-01

    A combined hyperbolic radiation and conduction heat transfer model is developed to simulate multi-time-scale heat transfer in turbid tissues exposed to short-pulsed irradiations. An initial temperature response of a tissue to an ultrashort pulse irradiation is analyzed by the volume-average method in combination with the transient discrete ordinates method for modeling the ultrafast radiation heat transfer. This response is found to reach pseudo steady state within 1 ns for the considered tissues. The single pulse result is then utilized to obtain the temperature response to pulse train irradiation at the microsecond/millisecond time scales. After that, the temperature field is predicted by the hyperbolic heat conduction model which is solved by the MacCormack's scheme with error terms correction. Finally, the hyperbolic conduction is compared with the traditional parabolic heat diffusion model. It is found that the maximum local temperatures are larger in the hyperbolic prediction than the parabolic prediction. In the modeled dermis tissue, a 7% non-dimensional temperature increase is found. After about 10 thermal relaxation times, thermal waves fade away and the predictions between the hyperbolic and parabolic models are consistent.

  17. Comparing patients with spinal cord infarction and cerebral infarction: clinical characteristics, and short-term outcome

    Directory of Open Access Journals (Sweden)

    Naess H

    2011-08-01

    Full Text Available Halvor Naess, Fredrik RomiDepartment of Neurology, Haukeland University Hospital, N-5021 Bergen, NorwayBackground: To compare the clinical characteristics, and short-term outcome of spinal cord infarction and cerebral infarction.Methods: Risk factors, concomitant diseases, neurological deficits on admission, and short-term outcome were registered among 28 patients with spinal cord infarction and 1075 patients with cerebral infarction admitted to the Department of Neurology, Haukeland University Hospital, Bergen, Norway. Multivariate analyses were performed with location of stroke (cord or brain, neurological deficits on admission, and short-term outcome (both Barthel Index [BI] 1 week after symptom onset and discharge home or to other institution as dependent variables.Results: Multivariate analysis showed that patients with spinal cord infarction were younger, more often female, and less afflicted by hypertension and cardiac disease than patients with cerebral infarction. Functional score (BI was lower among patients with spinal cord infarctions 1 week after onset of symptoms (P < 0.001. Odds ratio for being discharged home was 5.5 for patients with spinal cord infarction compared to cerebral infarction after adjusting for BI scored 1 week after onset (P = 0.019.Conclusion: Patients with spinal cord infarction have a risk factor profile that differs significantly from that of patients with cerebral infarction, although there are some parallels to cerebral infarction caused by atherosclerosis. Patients with spinal cord infarction were more likely to be discharged home when adjusting for early functional level on multivariate analysis.Keywords: spinal cord infarction, cerebral infarction, risk factors, short-term outcome

  18. A general dead-time correction method based on live-time stamping. Application to the measurement of short-lived radionuclides.

    Science.gov (United States)

    Chauvenet, B; Bobin, C; Bouchard, J

    2017-12-01

    Dead-time correction formulae are established in the general case of superimposed non-homogeneous Poisson processes. Based on the same principles as conventional live-timed counting, this method exploits the additional information made available using digital signal processing systems, and especially the possibility to store the time stamps of live-time intervals. No approximation needs to be made to obtain those formulae. Estimates of the variances of corrected rates are also presented. This method is applied to the activity measurement of short-lived radionuclides. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Nonlinear response of vessel walls due to short-time thermomechanical loading

    International Nuclear Information System (INIS)

    Pfeiffer, P.A.; Kulak, R.F.

    1994-01-01

    Maintaining structural integrity of the reactor pressure vessel (RPV) during a postulated core melt accident is an important safety consideration in the design of the vessel. This study addresses the failure predictions of the vessel due to thermal and pressure loadings fro the molten core debris depositing on the lower head of the vessel. Different loading combinations were considered based on the dead load, yield stress assumptions, material response and internal pressurization. The analyses considered only short term failure (quasi static) modes, long term failure modes were not considered. Short term failure modes include plastic instabilities of the structure and failure due to exceeding the failure strain. Long term failure odes would be caused by creep rupture that leads to plastic instability of the structure. Due to the sort time durations analyzed, creep was not considered in the analyses presented

  20. Impact of short- compared to long-haul international travel on the sleep and wellbeing of national wheelchair basketball athletes.

    Science.gov (United States)

    Thornton, Heidi R; Miller, Joanna; Taylor, Lee; Sargent, Charli; Lastella, Michele; Fowler, Peter M

    2018-07-01

    Currently, very little is known about the impact of short- or long-haul air travel on the sleep and wellbeing of wheelchair basketball athletes. Eleven national wheelchair basketball athletes wore actigraphy monitors prior, during, and after air travel to the United Kingdom. Upon arrival, participants rated their subjective jet-lag, fatigue, and vigor. Individuals traveled to the United Kingdom from different locations in Australia, the United States, and Europe and were categorised according to travel length [LONG (up to 30.2 h) or SHORT (up to 6.5 h)]. Linear mixed models determined effects of travel length on sleep and subjective ratings of jet-lag, fatigue, and vigor. During competition, subjective fatigue and jet-lag were substantially higher (ES = 0.73; ±0.77) and (ES = 0.57; ±0.60), subjective vigor was lower (ES = 1.94; ±0.72), and get-up time was earlier (ES = 0.57; ±0.60) for LONG when compared to SHORT. Travelling greater distances by airplane had a larger effect on subjective ratings of jet-lag, fatigue and vigor, rather than sleep. Irrespective of travel group, sleep and subjective responses were compromised, reflecting the travel requirements, competition-mediated influences, and/or due to a change in environment.

  1. Research on resistance characteristics of YBCO tape under short-time DC large current impact

    Science.gov (United States)

    Zhang, Zhifeng; Yang, Jiabin; Qiu, Qingquan; Zhang, Guomin; Lin, Liangzhen

    2017-06-01

    Research of the resistance characteristics of YBCO tape under short-time DC large current impact is the foundation of the developing DC superconducting fault current limiter (SFCL) for voltage source converter-based high voltage direct current system (VSC-HVDC), which is one of the valid approaches to solve the problems of renewable energy integration. SFCL can limit DC short-circuit and enhance the interrupting capabilities of DC circuit breakers. In this paper, under short-time DC large current impacts, the resistance features of naked tape of YBCO tape are studied to find the resistance - temperature change rule and the maximum impact current. The influence of insulation for the resistance - temperature characteristics of YBCO tape is studied by comparison tests with naked tape and insulating tape in 77 K. The influence of operating temperature on the tape is also studied under subcooled liquid nitrogen condition. For the current impact security of YBCO tape, the critical current degradation and top temperature are analyzed and worked as judgment standards. The testing results is helpful for in developing SFCL in VSC-HVDC.

  2. Short version of the Zimbardo Time Perspective Inventory (ZTPI-short) with and without the Future-Negative scale, verified on nationally representative samples

    Czech Academy of Sciences Publication Activity Database

    Košťál, Jaroslav; Klicperová-Baker, Martina; Lukavská, K.; Lukavský, Jiří

    2016-01-01

    Roč. 25, č. 2 (2016), s. 169-192 ISSN 0961-463X Institutional support: RVO:68081740 Keywords : ZTPI * ZTPI-short * time perspective * temporal orientation * representative sample Subject RIV: AN - Psychology Impact factor: 1.206, year: 2016

  3. Comparative study of the hydrogen generation during short term station blackout (STSBO) in a BWR

    International Nuclear Information System (INIS)

    Polo-Labarrios, M.A.; Espinosa-Paredes, G.

    2015-01-01

    Highlights: • Comparative study of generation in a simulated STSBO severe accident. • MELCOR and SCDAP/RELAP5 codes were used to understanding the main phenomena. • Both codes present similar thermal-hydraulic behavior for pressure and boil off. • SCDAP/RELAP5 predicts 15.8% lower hydrogen production than MELCOR. - Abstract: The aim of this work is the comparative study of hydrogen generation and the associated parameters in a simulated severe accident of a short-term station blackout (STSBO) in a typical BWR-5 with Mark-II containment. MELCOR (v.1.8.6) and SCDAP/RELAP5 (Mod.3.4) codes were used to understand the main phenomena in the STSBO event through the results comparison obtained from simulations with these codes. Due that the simulation scope of SCDAP/RELAP5 is limited to failure of the vessel pressure boundary, the comparison was focused on in-vessel severe accident phenomena; with a special interest in the vessel pressure, boil of cooling, core temperature, and hydrogen generation. The results show that at the beginning of the scenario, both codes present similar thermal-hydraulic behavior for pressure and boil off of cooling, but during the relocation, the pressure and boil off, present differences in timing and order of magnitude. Both codes predict in similar time the beginning of melting material drop to the lower head. As far as the hydrogen production rate, SCDAP/RELAP5 predicts 15.8% lower production than MELCOR

  4. Tests for nonlinearity in short stationary time series

    International Nuclear Information System (INIS)

    Chang, T.; Sauer, T.; Schiff, S.J.

    1995-01-01

    To compare direct tests for detecting determinism in chaotic time series, data from Henon, Lorenz, and Mackey--Glass equations were contaminated with various levels of additive colored noise. These data were analyzed with a variety of recently developed tests for determinism, and the results compared

  5. Shorting time of magnetically insulated reflex-ion diodes from the neutral-atom charge-exchange mechanism

    International Nuclear Information System (INIS)

    Strobel, G.

    1981-10-01

    In a magnetically insulated diode, collision-free electrons return to the cathode and no electron current is present at the anode. Electron transport to the anode is studied in this paper. Steady-state space-charge-limited flow is assumed initially. Breakdown of ion flow occurs when static neutral atoms at the anode undergo charge exchange, which results in neutral atoms drifting across the diode. These are subsequently ionized by reflexing ions producing electrons trapped in Larmor orbits throughout the diode. These electrons drift to the anode via ionization and inelastic collisions with other neutral atoms. Model calculations compare the effects of foil and mesh cathodes. Steady-state space-charge-limited ion current densities are calculated. The neutral atom density at the cathode is determined as a function of time. The shorting time of the diode is scaled versus the electrode separation d, the diode potential V 0 , the magnetic field, and the initial concentration of static neutron atoms

  6. Forecast model of landslides in a short time

    International Nuclear Information System (INIS)

    Sanchez Lopez, Reinaldo

    2006-01-01

    The IDEAM in development of their functions as member of the national technical committee for the prevention and disasters attention (SNPAD) accomplishes the follow-up, monitoring and forecast in real time of the environmental dynamics that in extreme situations constitute threats and natural risks. One of the frequent dynamics and of greater impact is related to landslides, those that affect persistently the life of the persons, the infrastructure, the socioeconomic activities and the balance of the environment. The landslide in Colombia and in the world are caused mainly by effects of the rain, due to that, IDEAM has come developing forecast model, as an instrument for risk management in a short time. This article presents aspects related to their structure, operation, temporary space resolution, products, results, achievements and projections of the model. Conceptually, the model is support by the principle of the dynamic temporary - space, of the processes that consolidate natural hazards, particularly in areas where the man has come building the risk. Structurally, the model is composed by two sub-models; the general susceptibility of the earthly model and the critical rain model as a denotative factor, that consolidate the hazard process. In real time, the model, works as a GIS, permitting the automatic zoning of the landslides hazard for issue public advisory warming to help makers decisions on the risk that cause frequently these events, in the country

  7. Comparison of Short vs Long Anti-rotation in Treating Trochanteric Fractures

    Directory of Open Access Journals (Sweden)

    Raval P

    2016-03-01

    Full Text Available Introduction: A comparative evaluation of the surgical treatment and outcome of patients with pertrochanteric fractures treated with short versus long proximal femoral nail antirotation. Materials and methods: A retrospective review was conducted of patients with pertrochanteric fractures treated between January 2011 and June 2012. In all 80 patients were enrolled in the study, of which 40 were treated with short PFNA and the remaining with long PFNA. Comparative analyses of demographic data, peri-operative outcome and complications were carried out. Results: There was no significant difference noted in the two groups with regards to Arbeitsgemeinschaft fur Osteosynthesefragen (AO fracture classification, time from injury to surgery, blood transfusion post surgery and hospital stay. The surgical duration for a short PFNA procedure was significantly less (58 minutes when compared to that of a long PFNA (87 minutes. Similarly intra-operative blood loss was significantly higher in the long PFNA group as compared to the short PFNA. Conclusions: A relatively quicker surgical time of just under an hour , lesser blood loss and better learning curve with trainee surgeons make short PFNA a better implant choice in the treatment of pertrochanteric fractures.

  8. Comparing Dislodgeable 2,4-D Residues across Athletic Field Turfgrass Species and Time.

    Directory of Open Access Journals (Sweden)

    Matthew D Jeffries

    Full Text Available 2,4-dimethylamine salt (2,4-D is an herbicide commonly applied on athletic fields for broadleaf weed control that can dislodge from treated turfgrass. Dislodge potential is affected by numerous factors, including turfgrass canopy conditions. Building on previous research confirming herbicide-turfgrass dynamics can vary widely between species, field research was initiated in 2014 and 2015 in Raleigh, NC, USA to quantify dislodgeable 2,4-D residues from dormant hybrid bermudagrass (Cynodon dactylon L. x C. transvaalensis and hybrid bermudagrass overseeded with perennial ryegrass (Lolium perenne L., which are common athletic field playing surfaces in subtropical climates. Additionally, dislodgeable 2,4-D was compared at AM (7:00 eastern standard time and PM (14:00 sample timings within a day. Samples collected from perennial ryegrass consistently resulted in greater 2,4-D dislodgment immediately after application (9.4 to 9.9% of applied compared to dormant hybrid bermudagrass (2.3 to 2.9%, as well as at all AM compared to PM timings from 1 to 3 d after treatment (DAT; 0.4 to 6.3% compared to 0.1 to 0.8%. Dislodgeable 2,4-D did not differ across turfgrass species at PM sample collections, with ≤ 0.1% of the 2,4-D applied dislodged from 1 to 6 DAT, and 2,4-D detection did not occur at 12 and 24 DAT. In conclusion, dislodgeable 2,4-D from treated turfgrass can vary between species and over short time-scales within a day. This information should be taken into account in human exposure risk assessments, as well as by turfgrass managers and athletic field event coordinators to minimize 2,4-D exposure.

  9. Forecast of electric power market to short-term: a time series approcah

    International Nuclear Information System (INIS)

    Costa, Roberio Neves Pelinca da.

    1994-01-01

    Three different time series approaches are analysed by this dissertation in the Brazilian electricity markert context. The aim is to compare the predictive performance of these approaches from a simulated exercise using the main series of the Brazilian consumption of electricity: Total Consumption, Industrial Consumption, Residencial Consumption and Commercial Consumption. One concludes that these appraches offer an enormous potentiality to the short-term planning system of the Electric Sector. Among the univariate models, the results for the analysed period point out that the forecast produced by Holt-Winter's models are more accurate than those produced by ARIMA and structural models. When explanatory variables are introduced in the last models, one can notice, in general, an improvement in the predictive performance of the models, although there is no sufficient evidence to consider that they are superior to Holt-Winter's models. The models with explanatory variables can be particularly useful, however, when one intends either to build scenarios or to study the effects of some variables on the consumption of electricity. (author). 73 refs., 19 figs., 13 tabs

  10. A Microgenetic/Cross-Sectional Study of Matrix Completion: Comparing Short-Term and Long-Term Change.

    Science.gov (United States)

    Siegler, Robert S.; Svetina, Matija

    2002-01-01

    This study examined 6- to 8-year-old Slovenian children's acquisition of matrix completion proficiency and compared microgenetic and age-related changes on the task. Microgenetic analyses indicated that: variability of children's errors increased before they discovered the correct strategy, the correct strategy became dominant shortly after…

  11. Short-time beta grain growth kinetics for a conventional titanium alloy

    International Nuclear Information System (INIS)

    Semiatin, S.L.; Sukonnik, I.M.

    1996-01-01

    The kinetics of beta grain growth during short-time, supertransus heat treatment of Ti-5Al-4V were determined using a salt-pot technique. The finite-time, subtransus temperature transient during salt-pot heating was quantified through measurements of the heat transfer coefficient characterizing conduction across the salt-titanium interface and a simple heat conduction analysis which incorporated this heat transfer coefficient. Grain size versus time data adjusted to account for the subtransus temperature transient were successfully fit to the parabolic grain growth law d n - d 0 n = kt exp(-Q/RT) using an exponent n equal to 2.0. Comparison of the present results to rapid, continuous heat treatment data in the literature for a similar titanium alloy revealed a number of semi-quantitative similarities

  12. Two Machine Learning Approaches for Short-Term Wind Speed Time-Series Prediction.

    Science.gov (United States)

    Ak, Ronay; Fink, Olga; Zio, Enrico

    2016-08-01

    The increasing liberalization of European electricity markets, the growing proportion of intermittent renewable energy being fed into the energy grids, and also new challenges in the patterns of energy consumption (such as electric mobility) require flexible and intelligent power grids capable of providing efficient, reliable, economical, and sustainable energy production and distribution. From the supplier side, particularly, the integration of renewable energy sources (e.g., wind and solar) into the grid imposes an engineering and economic challenge because of the limited ability to control and dispatch these energy sources due to their intermittent characteristics. Time-series prediction of wind speed for wind power production is a particularly important and challenging task, wherein prediction intervals (PIs) are preferable results of the prediction, rather than point estimates, because they provide information on the confidence in the prediction. In this paper, two different machine learning approaches to assess PIs of time-series predictions are considered and compared: 1) multilayer perceptron neural networks trained with a multiobjective genetic algorithm and 2) extreme learning machines combined with the nearest neighbors approach. The proposed approaches are applied for short-term wind speed prediction from a real data set of hourly wind speed measurements for the region of Regina in Saskatchewan, Canada. Both approaches demonstrate good prediction precision and provide complementary advantages with respect to different evaluation criteria.

  13. Randomized Controlled Study to Investigate the Effect of Topical Diquafosol Tetrasodium on Corneal Sensitivity in Short Tear Break-Up Time Dry Eye.

    Science.gov (United States)

    Kaido, Minako; Kawashima, Motoko; Shigeno, Yuta; Yamada, Yoshiaki; Tsubota, Kazuo

    2018-05-01

    Complex mechanisms underlie dry eye (DE) symptom provocation. In particular, corneal hypersensitivity may provoke symptoms in short tear break-up time (BUT) DE characterized by tear film instability. We hypothesized that improved tear film stability may alleviate corneal sensitivity in patients with short tear BUT DE. Therefore, we investigated the effect of topical diquafosol tetrasodium (DQS) on corneal sensitivity in unstable tear film DE. This prospective, randomized study included 27 subjects (age: 39.1 ± 8.4 years; range: 25-59 years) with short tear BUT DE, defined based on the presence of DE symptoms and tear film instability. Subjects were randomly divided into DQS (3% DQS, 12 subjects) and artificial tear (AT; preservative-free AT, 15 subjects) groups. Subjects applied the medication 6 times a day for 5 weeks. The perception of touch (S-touch) and pain (S-pain) sensitivity was measured using a Cochet-Bonnet esthesiometer. Tear evaluation, corneal sensitivity, and DE symptoms were compared before and after DQS or AT administration. The correlation between the improvement degrees of corneal sensitivity and DE symptoms following medication was analyzed. DQS significantly improved tear BUT and tear meniscus height (TMH) scores (p short tear BUT DE. However, DQS seems to be more effective to adjust tear environment, leading to the normalization of corneal sensitivity and DE symptoms. UMIN Clinical Trials Registry Identifier, UMIN000014536.

  14. Role of short-time acoustic temporal fine structure cues in sentence recognition for normal-hearing listeners.

    Science.gov (United States)

    Hou, Limin; Xu, Li

    2018-02-01

    Short-time processing was employed to manipulate the amplitude, bandwidth, and temporal fine structure (TFS) in sentences. Fifty-two native-English-speaking, normal-hearing listeners participated in four sentence-recognition experiments. Results showed that recovered envelope (E) played an important role in speech recognition when the bandwidth was > 1 equivalent rectangular bandwidth. Removing TFS drastically reduced sentence recognition. Preserving TFS greatly improved sentence recognition when amplitude information was available at a rate ≥ 10 Hz (i.e., time segment ≤ 100 ms). Therefore, the short-time TFS facilitates speech perception together with the recovered E and works with the coarse amplitude cues to provide useful information for speech recognition.

  15. Comparative timing measurements of LYSO and LFS-3 to achieve the best time resolution for TOF-PET

    CERN Document Server

    Doroud, K; Zichichi, A; Zuyeuski, R

    2015-01-01

    The best Coincidence Time Resolution (CTR) obtained so far – with very short crystals of 3–5 mm in length – reach values between 100 and 150 ps. Such crystals are not really practical for a TOF PET imaging device, since the sensitivity is quite small for the detection of the 511 keV gammas resulting from a positron annihilation. We present our setup and measurements using 15 mm length crystals; a length we regard as reasonable for a TOF-PET scanner. We have used a new series of Silicon Photo-Multipliers (SiPM) manufactured by Hamamatsu. These are the High Fill Factor (HFF) and Low Cross-Talk (LCT) Multi-Pixel Photon Counters (MPPC). We have compared three different crystals, LFS-3 (supplied by Zecotek) and two samples of LYSO (manufactured by Saint Gobain and CPI). We have obtained an excellent value of 148 ps for the Coincidence Time Resolution (CTR) with two LFS-3 crystals (15 mm long) mounted on each side of a 22Na radioactive source with the HFF-MPPCs at 3.3 V over-voltage. Our results are148 ps obt...

  16. The effect of long and short time oil shocks on economic growth in Iran

    OpenAIRE

    Sayyed Abdolmajid Jalae; Sanaz Mohammadi

    2012-01-01

    Oil is one of the strategic good so that price fluctuations and shocks of it have major effects on economic growth and recession in depended countries to revenues of it. In this study, it is tried that the effect of oil price shocks investigated in two types (short and long time) on Economic growth in Iran. Its Period is from 1974 to 2006. According it, oil price uncertainty is quantized by GARCH model and is determined the effects of oil price shocks on economic growth in Iran during a short...

  17. High-Temperature-Short-Time (HTST) sterilization of liquid food with solid particles; HTST steriliseren van vloeibare levensmiddelen met vaste deeltjes

    Energy Technology Data Exchange (ETDEWEB)

    Boon, F

    2000-11-01

    As part of a sectoral study for the Association of the Dutch Vegetable and Fruit Processing Industry (VIGEF) a project started on the Factory 2005 concept. Options to improve the product quality of canned vegetables and fruit are investigated. One of the options is to reduce the heat during the sterilization process by applying the HTST method (high-temperature-short-time). Two processes are compared: the Gierschner process and the Stork Steripart process. [Dutch] Binnen de VIGEF (Vereniging van de Nederlandse Groenten- en Fruitverwerkende Industrie) is een project gestart in samenwerking met TNO dat zich richt op de fabriek 2005. Onderzoek wordt gedaan naar de mogelijkheden om de productkwaliteit van geconserveerde groenten en fruit te verbeteren. Het richt zich o.a. op de mogelijkheden om de hitte-intensiteit tijdens de sterilisatie te verlagen door te steriliseren volgens de HTST methode (high-temperature-short-time). Motivatie voor de ontwikkeling van HTST processen is primair kwaliteitsverbetering met gelijke microbiele veiligheid (t.o.v. het conventionele proces). Er worden 2 processen vergeleken: het Gierschner proces en het Stork Steripart proces.

  18. Short locking time and low jitter phase-locked loop based on slope charge pump control

    International Nuclear Information System (INIS)

    Guo Zhongjie; Liu Youbao; Wu Longsheng; Wang Xihu; Tang Wei

    2010-01-01

    A novel structure of a phase-locked loop (PLL) characterized by a short locking time and low jitter is presented, which is realized by generating a linear slope charge pump current dependent on monitoring the output of the phase frequency detector (PFD) to implement adaptive bandwidth control. This improved PLL is created by utilizing a fast start-up circuit and a slope current control on a conventional charge pump PLL. First, the fast start-up circuit is enabled to achieve fast pre-charging to the loop filter. Then, when the output pulse of the PFD is larger than a minimum value, the charge pump current is increased linearly by the slope current control to ensure a shorter locking time and a lower jitter. Additionally, temperature variation is attenuated with the temperature compensation in the charge pump current design. The proposed PLL has been fabricated in a kind of DSP chip based on a 0.35 μm CMOS process. Comparing the characteristics with the classical PLL, the proposed PLL shows that it can reduce the locking time by 60% with a low peak-to-peak jitter of 0.3% at a wide operation temperature range. (semiconductor integrated circuits)

  19. Short-time maximum entropy method analysis of molecular dynamics simulation: Unimolecular decomposition of formic acid

    Science.gov (United States)

    Takahashi, Osamu; Nomura, Tetsuo; Tabayashi, Kiyohiko; Yamasaki, Katsuyoshi

    2008-07-01

    We performed spectral analysis by using the maximum entropy method instead of the traditional Fourier transform technique to investigate the short-time behavior in molecular systems, such as the energy transfer between vibrational modes and chemical reactions. This procedure was applied to direct ab initio molecular dynamics calculations for the decomposition of formic acid. More reactive trajectories of dehydrolation than those of decarboxylation were obtained for Z-formic acid, which was consistent with the prediction of previous theoretical and experimental studies. Short-time maximum entropy method analyses were performed for typical reactive and non-reactive trajectories. Spectrograms of a reactive trajectory were obtained; these clearly showed the reactant, transient, and product regions, especially for the dehydrolation path.

  20. New solutions for the short-time analysis of geothermal vertical boreholes

    Energy Technology Data Exchange (ETDEWEB)

    Lamarche, Louis; Beauchamp, Benoit [Ecole de Technologie Supereure, 1100 Notre-Dame Ouest, Montreal (Canada)

    2007-04-15

    Many models, either numerical or analytical, have been proposed to analyse the thermal response of vertical heat exchangers that are used in ground coupled heat pump systems (GCHP). In both approaches, most of the models are valid after few hours of operation since they neglect the heat capacity of the borehole. This is valid for design purposes, where the time of interest is in the order of months and years. Recently, the short time response of vertical boreholes became a subject of interest. In this paper, we present a new analytical approach to treat this problem. It solves the exact solution for concentric cylinders and is a good approximation for the familiar U-tube configuration. (author)

  1. Burn-up measurements of LEU fuel for short cooling times

    International Nuclear Information System (INIS)

    Pereda B, C.; Henriquez A, C.; Klein D, J.; Medel R, J.

    2005-01-01

    The measurements presented in this work were made essentially at in-pool gamma-spectrometric facility, installed inside of the secondary pool of the RECH-1 research reactor, where the measured fuel elements are under 2 meters of water. The main reason for using the in-pool facility was because of its capability to measure the burning of fuel elements without having to wait so long, that is with only 5 cooling days, which are the usual times between reactor operations. Regarding these short cooling times, this work confirms again the possibility of using the 95 Zr as a promising burnup monitor, in spite of the rough approximations used to do it. These results are statistically reasonable within the range calculated using codes. The work corroborates previous results, presented in Santiago de Chile, and it suggests future improvements in that way. (author)

  2. The effect of charging time on the comparative environmental performance of different vehicle types

    International Nuclear Information System (INIS)

    Crossin, Enda; Doherty, Peter J.B.

    2016-01-01

    Highlights: • The environmental performance of a PHEV and equivalent ICE were analysed using LCA. • Charging behaviour and electricity profiles of Australia’s NEM grid were included. • A methodology to model the marginal electricity supply mix was developed. • PHEVs charged from the NEM present greenhouse gas benefits. • Burden shifts towards other environmental indicators may occur, but are uncertain. - Abstract: This study combines electricity supply mix profiles and observed charging behaviour to compare the environmental performance of a petrol-hybrid electric vehicle (PHEV) with a class-equivalent internal combustion engine (ICE) vehicle over the full life cycle. Environmental performance is compared using a suite of indicators across the life cycle, accounting for both marginal and average electricity supply mixes for Australia’s National Energy Market (NEM) grid. The use of average emission factors for the NEM grid can serve as a good proxy for accounting charging behaviour, provided that there is a strong correlation between the time of charging and total electricity demand. Compared with an equivalent ICE, PHEVs charged from Australia’s NEM can reduce greenhouse gas emissions over the life cycle. Potential burden shifts towards acidification, eutrophication and human toxicity impacts may occur, but these impacts are uncertain due to modelling limitations. This study has the potential to inform both short and long term forecasts of the environmental impacts associated with EV deployment in Australia and provides a better understanding the temporal variations in emissions associated with electricity use in the short term.

  3. High-Temperature-Short-Time Annealing Process for High-Performance Large-Area Perovskite Solar Cells.

    Science.gov (United States)

    Kim, Minjin; Kim, Gi-Hwan; Oh, Kyoung Suk; Jo, Yimhyun; Yoon, Hyun; Kim, Ka-Hyun; Lee, Heon; Kim, Jin Young; Kim, Dong Suk

    2017-06-27

    Organic-inorganic hybrid metal halide perovskite solar cells (PSCs) are attracting tremendous research interest due to their high solar-to-electric power conversion efficiency with a high possibility of cost-effective fabrication and certified power conversion efficiency now exceeding 22%. Although many effective methods for their application have been developed over the past decade, their practical transition to large-size devices has been restricted by difficulties in achieving high performance. Here we report on the development of a simple and cost-effective production method with high-temperature and short-time annealing processing to obtain uniform, smooth, and large-size grain domains of perovskite films over large areas. With high-temperature short-time annealing at 400 °C for 4 s, the perovskite film with an average domain size of 1 μm was obtained, which resulted in fast solvent evaporation. Solar cells fabricated using this processing technique had a maximum power conversion efficiency exceeding 20% over a 0.1 cm 2 active area and 18% over a 1 cm 2 active area. We believe our approach will enable the realization of highly efficient large-area PCSs for practical development with a very simple and short-time procedure. This simple method should lead the field toward the fabrication of uniform large-scale perovskite films, which are necessary for the production of high-efficiency solar cells that may also be applicable to several other material systems for more widespread practical deployment.

  4. Generic short-time propagation of sharp-boundaries wave packets

    Science.gov (United States)

    Granot, E.; Marchewka, A.

    2005-11-01

    A general solution to the "shutter" problem is presented. The propagation of an arbitrary initially bounded wave function is investigated, and the general solution for any such function is formulated. It is shown that the exact solution can be written as an expression that depends only on the values of the function (and its derivatives) at the boundaries. In particular, it is shown that at short times (t << 2mx2/hbar, where x is the distance to the boundaries) the wave function propagation depends only on the wave function's values (or its derivatives) at the boundaries of the region. Finally, we generalize these findings to a non-singular wave function (i.e., for wave packets with finite-width boundaries) and suggest an experimental verification.

  5. Efficient Computation of Multiscale Entropy over Short Biomedical Time Series Based on Linear State-Space Models

    Directory of Open Access Journals (Sweden)

    Luca Faes

    2017-01-01

    Full Text Available The most common approach to assess the dynamical complexity of a time series across multiple temporal scales makes use of the multiscale entropy (MSE and refined MSE (RMSE measures. In spite of their popularity, MSE and RMSE lack an analytical framework allowing their calculation for known dynamic processes and cannot be reliably computed over short time series. To overcome these limitations, we propose a method to assess RMSE for autoregressive (AR stochastic processes. The method makes use of linear state-space (SS models to provide the multiscale parametric representation of an AR process observed at different time scales and exploits the SS parameters to quantify analytically the complexity of the process. The resulting linear MSE (LMSE measure is first tested in simulations, both theoretically to relate the multiscale complexity of AR processes to their dynamical properties and over short process realizations to assess its computational reliability in comparison with RMSE. Then, it is applied to the time series of heart period, arterial pressure, and respiration measured for healthy subjects monitored in resting conditions and during physiological stress. This application to short-term cardiovascular variability documents that LMSE can describe better than RMSE the activity of physiological mechanisms producing biological oscillations at different temporal scales.

  6. Comparing Short Dental Implants to Standard Dental Implants: Protocol for a Systematic Review.

    Science.gov (United States)

    Rokn, Amir Reza; Keshtkar, Abbasali; Monzavi, Abbas; Hashemi, Kazem; Bitaraf, Tahereh

    2018-01-18

    Short dental implants have been proposed as a simpler, cheaper, and faster alternative for the rehabilitation of atrophic edentulous areas to avoid the disadvantages of surgical techniques for increasing bone volume. This review will compare short implants (4 to 8 mm) to standard implants (larger than 8 mm) in edentulous jaws, evaluating on the basis of marginal bone loss (MBL), survival rate, complications, and prosthesis failure. We will electronically search for randomized controlled trials comparing short dental implants to standard dental implants in the following databases: PubMed, Web of Science, EMBASE, Scopus, the Cochrane Central Register of Controlled Trials, and ClinicalTrials.gov with English language restrictions. We will manually search the reference lists of relevant reviews and the included articles in this review. The following journals will also be searched: European Journal of Oral Implantology, Clinical Oral Implants Research, and Clinical Implant Dentistry and Related Research. Two reviewers will independently perform the study selection, data extraction and quality assessment (using the Cochrane Collaboration tool) of included studies. All meta-analysis procedures including appropriate effect size combination, sub-group analysis, meta-regression, assessing publication or reporting bias will be performed using Stata (Statacorp, TEXAS) version 12.1. Short implant effectiveness will be assessed using the mean difference of MBL in terms of weighted mean difference (WMD) and standardized mean difference (SMD) using Cohen's method. The combined effect size measures in addition to the related 95% confidence intervals will be estimated by a fixed effect model. The heterogeneity of the related effect size will be assessed using a Q Cochrane test and I2 measure. The MBL will be presented by a standardized mean difference with a 95% confidence interval. The survival rate of implants, prostheses failures, and complications will be reported using a risk

  7. A comparative study of boar semen extenders with different proposed preservation times and their effect on semen quality and fertility

    Directory of Open Access Journals (Sweden)

    Marina Anastasia Karageorgiou

    2016-01-01

    Full Text Available The present study compared the quality characteristics of boar semen diluted with three extenders of different proposed preservation times (short-term, medium-term and long-term. A part of extended semen was used for artificial insemination on the farm (30 sows/extender, while the remaining part was stored for three days (16–18 °C. Stored and used semen was also laboratory assessed at insemination time, on days 1 and 2 after the collection (day 0. The long-term extender was used for a short time, within 2 days from semen collection, with the aim to investigate a possible advantage over the others regarding laboratory or farm fertility indicators at the beginning of the preservation time. Viability, motility, kinetic indicators, morphology and DNA fragmentation were estimated. The results showed reduced viability, higher values for most of the kinetics, and higher immotile spermatozoa from day 1 to day 2 in all extenders; however, the long-term extender was superior compared to the other two on both days. With regard to morphology and chromatin integrity, the percentage of abnormal and fragmented spermatozoa increased on day 2 compared to day 1 for all of the extenders. However, based on the farrowing rate and the number of piglets born alive after the application of conventional artificial insemination within 2 days from semen collection/dilution, it was found that the medium-term diluents were more effective. In conclusion, it seems that the in vivo fertilization process involves more factors than simply the quality of laboratory evaluated sperm indicators, warranting further research.

  8. Identification of the structure parameters using short-time non-stationary stochastic excitation

    Science.gov (United States)

    Jarczewska, Kamila; Koszela, Piotr; Śniady, PaweŁ; Korzec, Aleksandra

    2011-07-01

    In this paper, we propose an approach to the flexural stiffness or eigenvalue frequency identification of a linear structure using a non-stationary stochastic excitation process. The idea of the proposed approach lies within time domain input-output methods. The proposed method is based on transforming the dynamical problem into a static one by integrating the input and the output signals. The output signal is the structure reaction, i.e. structure displacements due to the short-time, irregular load of random type. The systems with single and multiple degrees of freedom, as well as continuous systems are considered.

  9. Automated Detection of Short Optical Transients of Astrophysical Origin in Real Time

    Directory of Open Access Journals (Sweden)

    Marcin Sokołowski

    2010-01-01

    Full Text Available The detection of short optical transients of astrophysical origin in real time is an important task for existing robotic telescopes. The faster a new optical transient is detected, the earlier follow-up observations can be started. The sooner the object is identified, the more data can be collected before the source fades away, particularly in the most interesting early period of the transient. In this the real-time pipeline designed for identification of optical flashes with the “Pi of the Sky” project will be presented in detail together with solutions used by other experiments.

  10. Influence of Short-time Oxidation on Corrosion Properties of Directionally Solidified Superalloys with Different Orientations

    Directory of Open Access Journals (Sweden)

    MA Luo-ning

    2016-07-01

    Full Text Available In order to investigate the corrosion performance on intersecting and longitudinal surfaces of unoxidized and oxidized directionally solidified superalloys, Ni-base directionally solidified superalloy DZ125 and Co-base directionally solidified superalloy DZ40M were selected. Oxidation behavior on both alloys with different orientations was investigated at 1050℃ at different times, simulating the oxidation process of vanes or blades in service; subsequent electrochemical performance in 3.5%NaCl aqueous solution was studied on two orientations of unoxidized and oxidized alloys, simulating the corrosion process of superalloy during downtime. The results show that grain boundaries and sub-boundaries of directionally solidified superalloys are susceptible to corrosion and thus longitudinal surface with lower area fraction of grain boundaries has higher corrosion resistance. Compared to intersecting surface of alloys, the structure of grain boundaries of longitudinal surface is less conducive to diffusion and thus the oxidation rate on longitudinal surface is lower. Formation of oxide layers on alloys after short-time oxidation provides protective effect and enhances the corrosion resistance.

  11. Retention time generates short-term phytoplankton blooms in a shallow microtidal subtropical estuary

    Science.gov (United States)

    Odebrecht, Clarisse; Abreu, Paulo C.; Carstensen, Jacob

    2015-09-01

    In this study it was hypothesised that increasing water retention time promotes phytoplankton blooms in the shallow microtidal Patos Lagoon estuary (PLE). This hypothesis was tested using salinity variation as a proxy of water retention time and chlorophyll a for phytoplankton biomass. Submersible sensors fixed at 5 m depth near the mouth of PLE continuously measured water temperature, salinity and pigments fluorescence (calibrated to chlorophyll a) between March 2010 and 12th of December 2011, with some gaps. Salinity variations were used to separate alternating patterns of outflow of lagoon water (salinity 24; 35% of the time). The two transition phases represented a rapid change from lagoon water outflow to marine water inflow and a more gradually declining salinity between the dominating inflow and outflow conditions. During the latter of these, a significant chlorophyll a increase relative to that expected from a linear mixing relationship was observed at intermediate salinities (10-20). The increase in chlorophyll a was positively related to the duration of the prior coastal water inflow in the PLE. Moreover, chlorophyll a increase was significantly higher during austral spring-summer than autumn-winter, probably due to higher light and nutrient availability in the former. Moreover, the retention time process operating on time scales of days influences the long-term phytoplankton variability in this ecosystem. Comparing these results with monthly data from a nearby long-term water quality monitoring station (1993-2011) support the hypothesis that chlorophyll a accumulations occur after marine inflow events, whereas phytoplankton does not accumulate during high water outflow, when the water residence time is short. These results suggest that changing hydrological pattern is the most important mechanism underlying phytoplankton blooms in the PLE.

  12. Investigation of the motion of diesel injection jets using high-speed cinematography and short time holography

    International Nuclear Information System (INIS)

    Eisfeld, F.

    1987-01-01

    The knowledge about the penetration of diesel injection jets, particularly about the flow within the short behind the nozzle, and the arising of droplets from an injection jet is very limited. Experimental investigations are required to describe the process of penetration and spreading of the jet. The research method requires high speed cinematography and short time holography. Problems in the investigation method are described

  13. Comparing return to sport activities after short metaphyseal femoral arthroplasty with resurfacing and big femoral head arthroplasties.

    Science.gov (United States)

    Karampinas, Panagiotis K; Papadelis, Eustratios G; Vlamis, John A; Basiliadis, Hlias; Pneumaticos, Spiros G

    2017-07-01

    Young patients feel that maintaining sport activities after total hip arthroplasty constitutes an important part of their quality of life. The majority of hip surgeons allow patients to return to low-impact activities, but significant caution is advised to taking part in high-impact activities. The purpose of this study is to compare and evaluate the post-operative return to daily living habits and sport activities following short-metaphyseal hip and high functional total hip arthroplasties (resurfacing and big femoral head arthroplasties). In a study design, 48 patients (55 hips) were enrolled in three different comparative groups, one with the short-metaphyseal arthroplasties, a second with high functional resurfacing arthroplasties and a third of big femoral head arthroplasties. Each patient experienced a clinical examination and evaluated with Harris Hip Score, WOMAC, Sf-36, UCLA activity score, satisfaction VAS, anteroposterior and lateral X-rays of the hip and were followed in an outpatient setting for 2 years. Statistical analysis revealed no notable differences between the three groups regarding their demographic data however significant differences have been found between preoperative and postoperative clinical scores of each group. Also, we fail to reveal any significant differences when comparing data of all three groups at the final 2 years postoperative control regarding their clinical scores. The overall outcome of all three groups was similar, all the patients were satisfied and returned to previous level of sport activities. Short metaphyseal hip arthroplasties in young patients intending to return to previous and even high impact sport activities, similar to high functional resurfacing, big femoral head arthroplasties. Short stems with hard on hard bearing surfaces might become an alternative to standard stems and hip resurfacing.

  14. The short-term effects of air pollutants on respiratory disease mortality in Wuhan, China: comparison of time-series and case-crossover analyses.

    Science.gov (United States)

    Ren, Meng; Li, Na; Wang, Zhan; Liu, Yisi; Chen, Xi; Chu, Yuanyuan; Li, Xiangyu; Zhu, Zhongmin; Tian, Liqiao; Xiang, Hao

    2017-01-13

    Few studies have compared different methods when exploring the short-term effects of air pollutants on respiratory disease mortality in Wuhan, China. This study assesses the association between air pollutants and respiratory disease mortality with both time-series and time-stratified-case-crossover designs. The generalized additive model (GAM) and the conditional logistic regression model were used to assess the short-term effects of air pollutants on respiratory disease mortality. Stratified analyses were performed by age, sex, and diseases. A 10 μg/m 3 increment in SO 2 level was associated with an increase in relative risk for all respiratory disease mortality of 2.4% and 1.9% in the case-crossover and time-series analyses in single pollutant models, respectively. Strong evidence of an association between NO 2 and daily respiratory disease mortality among men or people older than 65 years was found in the case-crossover study. There was a positive association between air pollutants and respiratory disease mortality in Wuhan, China. Both time-series and case-crossover analyses consistently reveal the association between three air pollutants and respiratory disease mortality. The estimates of association between air pollution and respiratory disease mortality from the case-crossover analysis displayed greater variation than that from the time-series analysis.

  15. Timing of introduction of complementary food: short- and long-term health consequences.

    Science.gov (United States)

    Przyrembel, Hildegard

    2012-01-01

    Complementary food is needed when breast milk (or infant formula) alone is no longer sufficient for both nutritional and developmental reasons. The timing of its introduction, therefore, is an individual decision, although 6 months of exclusive breastfeeding can be recommended for most healthy term infants. The new foods are intended to 'complement' ongoing breastfeeding with those dietary items whose intake has become marginal or insufficient. Both breastfeeding and complementary feeding can have direct or later consequences on health. The evaluation of consequences of both early and late introduction of complementary food can neither disregard the effect of breastfeeding compared to formula feeding nor the composition or quality of the complementary food. Possible short-term health effects concern growth velocity and infections, and possible long-term effects may relate to atopic diseases, type 1 and 2 diabetes, obesity and neuromuscular development. On the basis of the currently available evidence, it is impossible to exactly determine the age when risks related to the start of complementary feeding are lowest or highest for most of these effects, with the possible exception of infections and early growth velocity. The present knowledge on undesirable health effects, however, is mainly based on observational studies, and although some mechanisms have been proposed, further prospective studies have to clarify these unsolved issues. Even less evidence on the consequences of the timing of complementary food introduction is available for formula-fed infants. Copyright © 2012 S. Karger AG, Basel.

  16. Short-Term Bus Passenger Demand Prediction Based on Time Series Model and Interactive Multiple Model Approach

    Directory of Open Access Journals (Sweden)

    Rui Xue

    2015-01-01

    Full Text Available Although bus passenger demand prediction has attracted increased attention during recent years, limited research has been conducted in the context of short-term passenger demand forecasting. This paper proposes an interactive multiple model (IMM filter algorithm-based model to predict short-term passenger demand. After aggregated in 15 min interval, passenger demand data collected from a busy bus route over four months were used to generate time series. Considering that passenger demand exhibits various characteristics in different time scales, three time series were developed, named weekly, daily, and 15 min time series. After the correlation, periodicity, and stationarity analyses, time series models were constructed. Particularly, the heteroscedasticity of time series was explored to achieve better prediction performance. Finally, IMM filter algorithm was applied to combine individual forecasting models with dynamically predicted passenger demand for next interval. Different error indices were adopted for the analyses of individual and hybrid models. The performance comparison indicates that hybrid model forecasts are superior to individual ones in accuracy. Findings of this study are of theoretical and practical significance in bus scheduling.

  17. Short daily hemodialysis is associated with lower plasma FGF23 levels when compared with conventional hemodialysis.

    Science.gov (United States)

    Zaritsky, Joshua; Rastogi, Anjay; Fischmann, George; Yan, Jieshi; Kleinman, Kenneth; Chow, Georgina; Gales, Barbara; Salusky, Isidro B; Wesseling-Perry, Katherine

    2014-02-01

    The utilization of short-term daily hemodialysis has increased over the last few years, but little is known on its effects on the control of serum phosphate and fibroblast growth factor 23 (FGF23) levels. We therefore performed a cross-sectional study to compare FGF23 levels as well as other biochemical variables between 24 patients undergoing short daily hemodialysis using the NxStage System® and 54 patients treated with conventional in-center hemodialysis. FGF23 levels were measured using the second-generation Immutopics® C-terminal assay. Short daily hemodialysis patients were younger than patients on conventional hemodialysis but there were no differences between groups in the duration of end-stage renal disease nor in the number of patients with residual renal function. A greater number of short daily hemodialysis patients received vitamin D sterol therapy than did conventional in-center hemodialysis patients while there were no differences in the use of different phosphate binders and calcimimetic therapy between groups. Overall serum calcium, phosphorus and intact parathyroid hormone levels were similar between groups. While serum phosphorus levels correlated with FGF23 concentrations in each group separately [r=0.522 (P<0.01) and r=0.42 (P<0.01) in short daily and conventional in-center hemodialysis, respectively], FGF23 levels were lower [823 RU/mL (263, 2169)] in the patients receiving short daily hemodialysis than in patients treated with conventional hemodialysis [2521 RU/mL (909, 5556)] (P<0.01 between groups). These findings demonstrate that FGF23 levels are significantly lower in short daily hemodialysis patients and suggest that FGF23 levels may be a more sensitive biomarker of cumulative phosphate burden than single or multiple serum phosphorus determinations in patients treated with hemodialysis.

  18. Habitual short sleep impacts frontal switch mechanism in attention to novelty.

    Science.gov (United States)

    Gumenyuk, Valentina; Roth, Thomas; Korzyukov, Oleg; Jefferson, Catherine; Bowyer, Susan; Drake, Christopher L

    2011-12-01

    Reduced time in bed relative to biological sleep need is common. The impact of habitual short sleep on auditory attention has not been studied to date. In the current study, we utilized novelty oddball tasks to evaluate the effect of habitual short sleep on brain function underlying attention control processes measured by the mismatch negativity (MMN, index of pre-attentive stage), P3a (attention-dependent), and P3b (memory-dependent) event related brain potentials (ERPs). An extended time in bed in a separate study was used to evaluate the possible reversal of the impairments of these processes in habitual short sleepers. Ten self-defined short sleepers (total sleep time [TST] ≤ 6 h) and 9 normal-sleeping subjects with TST 7-8 h, participated. ERPs were recorded via a 64-channel EEG system. Two test conditions: "ignore" and "attend" were implemented. The ERPs were analyzed and compared between groups on the 2 task conditions and frontal/central/parietal electrodes by 3-factor ANOVA. Sleep diary data were compared between groups by t-test. Sleep was recorded by the Zeo sleep monitoring system for a week in both habitual and extended sleep conditions at home. The main findings of the present study show that short sleeping individuals had deficiency in activity of the MMN and P3a brain responses over frontal areas compared to normal-sleeping subjects. The P3b amplitude was increased over frontal areas and decreased over parietal with respect to the control group. Extension of time in bed for one week increased TST (from 5.7 h to 7.4 h), and concomitantly MMN amplitude increased from -0.1 μV up to -1.25 μV over frontal areas. Reduced time in bed is associated with deficiency of the neuronal process associated with change detection, which may recover after one week of sleep extension, whereas attention-dependent neural processes do not normalize after this period of time in habitually short sleeping individuals and may require longer recovery periods.

  19. Time-Based Loss in Visual Short-Term Memory Is from Trace Decay, Not Temporal Distinctiveness

    Science.gov (United States)

    Ricker, Timothy J.; Spiegel, Lauren R.; Cowan, Nelson

    2014-01-01

    There is no consensus as to why forgetting occurs in short-term memory tasks. In past work, we have shown that forgetting occurs with the passage of time, but there are 2 classes of theories that can explain this effect. In the present work, we investigate the reason for time-based forgetting by contrasting the predictions of temporal…

  20. Short time-scale optical variability properties of the largest AGN sample observed with Kepler/K2

    Science.gov (United States)

    Aranzana, E.; Körding, E.; Uttley, P.; Scaringi, S.; Bloemen, S.

    2018-05-01

    We present the first short time-scale (˜hours to days) optical variability study of a large sample of active galactic nuclei (AGNs) observed with the Kepler/K2 mission. The sample contains 252 AGN observed over four campaigns with ˜30 min cadence selected from the Million Quasar Catalogue with R magnitude <19. We performed time series analysis to determine their variability properties by means of the power spectral densities (PSDs) and applied Monte Carlo techniques to find the best model parameters that fit the observed power spectra. A power-law model is sufficient to describe all the PSDs of our sample. A variety of power-law slopes were found indicating that there is not a universal slope for all AGNs. We find that the rest-frame amplitude variability in the frequency range of 6 × 10-6-10-4 Hz varies from 1to10 per cent with an average of 1.7 per cent. We explore correlations between the variability amplitude and key parameters of the AGN, finding a significant correlation of rest-frame short-term variability amplitude with redshift. We attribute this effect to the known `bluer when brighter' variability of quasars combined with the fixed bandpass of Kepler data. This study also enables us to distinguish between Seyferts and blazars and confirm AGN candidates. For our study, we have compared results obtained from light curves extracted using different aperture sizes and with and without detrending. We find that limited detrending of the optimal photometric precision light curve is the best approach, although some systematic effects still remain present.

  1. Evaluation of skeletal muscle during exercise on short repetition time MR imaging

    International Nuclear Information System (INIS)

    Yoshioka, Hiroshi; Niitsu, Mamoru; Anno, Izumi; Takahashi, Hideyuki; Kuno, Shinya; Matsumoto, Kunihiko; Itai, Yuji

    1992-01-01

    There have been many reports on the effects of exercise on skeletal muscle signal intensities based on magnetic resonance (MR) imaging. These images were obtained using T 2 -weighted MR images. The purpose of this study was to observe muscles during exercise while shortening the repetition time (TR) on spin echo images. In addition, inactive and active muscles were differentiated in the same manner. T 2 values of the tibialis anterior m. were calculated from TR=400 ms to TR=3000 ms. These values were mostly constant and didn't depend upon TR. Increases in signal intensities of the exercise muscles could be observed on the short TR (600 ms) MR images since the changes of the signal intensities mainly depend upon T 2 values. Thus, the T 2 value is useful as a quantitative index to assess the exercise muscle even on the short TR MR images. (author)

  2. Water-selective excitation of short T2 species with binomial pulses.

    Science.gov (United States)

    Deligianni, Xeni; Bär, Peter; Scheffler, Klaus; Trattnig, Siegfried; Bieri, Oliver

    2014-09-01

    For imaging of fibrous musculoskeletal components, ultra-short echo time methods are often combined with fat suppression. Due to the increased chemical shift, spectral excitation of water might become a favorable option at ultra-high fields. Thus, this study aims to compare and explore short binomial excitation schemes for spectrally selective imaging of fibrous tissue components with short transverse relaxation time (T2 ). Water selective 1-1-binomial excitation is compared with nonselective imaging using a sub-millisecond spoiled gradient echo technique for in vivo imaging of fibrous tissue at 3T and 7T. Simulations indicate a maximum signal loss from binomial excitation of approximately 30% in the limit of very short T2 (0.1 ms), as compared to nonselective imaging; decreasing rapidly with increasing field strength and increasing T2 , e.g., to 19% at 3T and 10% at 7T for T2 of 1 ms. In agreement with simulations, a binomial phase close to 90° yielded minimum signal loss: approximately 6% at 3T and close to 0% at 7T for menisci, and for ligaments 9% and 13%, respectively. Overall, for imaging of short-lived T2 components, short 1-1 binomial excitation schemes prove to offer marginal signal loss especially at ultra-high fields with overall improved scanning efficiency. Copyright © 2013 Wiley Periodicals, Inc.

  3. A comparative study of boar semen extenders with different proposed preservation times and their effect on semen quality and fertility

    OpenAIRE

    Marina Anastasia Karageorgiou; Georgios Tsousis; Constantin M. Boscos; Eleni D. Tzika; Panagiotis D. Tassis; Ioannis A. Tsakmakidis

    2016-01-01

    The present study compared the quality characteristics of boar semen diluted with three extenders of different proposed preservation times (short-term, medium-term and long-term). A part of extended semen was used for artificial insemination on the farm (30 sows/extender), while the remaining part was stored for three days (16–18 °C). Stored and used semen was also laboratory assessed at insemination time, on days 1 and 2 after the collection (day 0). The long-term extender was used for a sho...

  4. Short echo time proton spectroscopy of the brain in healthy volunteers using an insert gradient head coil

    DEFF Research Database (Denmark)

    Gideon, P; Danielsen, E R; Schneider, M

    1995-01-01

    An insert gradient head coil with built-in X, Y, and Z gradients was used for localized proton spectroscopy in the brain of healthy volunteers, using short echo time stimulated echo acquisition mode (STEAM) sequences. Volume of interest size was 3.4 ml, repetition time was 6.0 s, and echo times...... were 10 and 20 ms, respectively. Good quality proton spectra with practically no eddy current artefacts were acquired allowing observation of strongly coupled compounds, and compounds with short T2 relaxation times. The gradient head coil thus permits further studies of compounds such as glutamine....../glutamate and myo-inositols. These compounds were more prominent within grey matter than within white matter. Rough estimations of metabolite concentrations using water as an internal standard were in good agreement with previous reports....

  5. Nonlinear detection of disordered voice productions from short time series based on a Volterra-Wiener-Korenberg model

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Yu, E-mail: yuzhang@xmu.edu.cn [Key Laboratory of Underwater Acoustic Communication and Marine Information Technology of the Ministry of Education, Xiamen University, Xiamen Fujian 361005 (China); Sprecher, Alicia J. [Department of Surgery, Division of Otolaryngology - Head and Neck Surgery, University of Wisconsin School of Medicine and Public Health, Madison, WI 53792-7375 (United States); Zhao Zongxi [Key Laboratory of Underwater Acoustic Communication and Marine Information Technology of the Ministry of Education, Xiamen University, Xiamen Fujian 361005 (China); Jiang, Jack J. [Department of Surgery, Division of Otolaryngology - Head and Neck Surgery, University of Wisconsin School of Medicine and Public Health, Madison, WI 53792-7375 (United States)

    2011-09-15

    Highlights: > The VWK method effectively detects the nonlinearity of a discrete map. > The method describes the chaotic time series of a biomechanical vocal fold model. > Nonlinearity in laryngeal pathology is detected from short and noisy time series. - Abstract: In this paper, we apply the Volterra-Wiener-Korenberg (VWK) model method to detect nonlinearity in disordered voice productions. The VWK method effectively describes the nonlinearity of a third-order nonlinear map. It allows for the analysis of short and noisy data sets. The extracted VWK model parameters show an agreement with the original nonlinear map parameters. Furthermore, the VWK mode method is applied to successfully assess the nonlinearity of a biomechanical voice production model simulating irregular vibratory dynamics of vocal folds with a unilateral vocal polyp. Finally, we show the clinical applicability of this nonlinear detection method to analyze the electroglottographic data generated by 14 patients with vocal nodules or polyps. The VWK model method shows potential in describing the nonlinearity inherent in disordered voice productions from short and noisy time series that are common in the clinical setting.

  6. Nonlinear detection of disordered voice productions from short time series based on a Volterra-Wiener-Korenberg model

    International Nuclear Information System (INIS)

    Zhang Yu; Sprecher, Alicia J.; Zhao Zongxi; Jiang, Jack J.

    2011-01-01

    Highlights: → The VWK method effectively detects the nonlinearity of a discrete map. → The method describes the chaotic time series of a biomechanical vocal fold model. → Nonlinearity in laryngeal pathology is detected from short and noisy time series. - Abstract: In this paper, we apply the Volterra-Wiener-Korenberg (VWK) model method to detect nonlinearity in disordered voice productions. The VWK method effectively describes the nonlinearity of a third-order nonlinear map. It allows for the analysis of short and noisy data sets. The extracted VWK model parameters show an agreement with the original nonlinear map parameters. Furthermore, the VWK mode method is applied to successfully assess the nonlinearity of a biomechanical voice production model simulating irregular vibratory dynamics of vocal folds with a unilateral vocal polyp. Finally, we show the clinical applicability of this nonlinear detection method to analyze the electroglottographic data generated by 14 patients with vocal nodules or polyps. The VWK model method shows potential in describing the nonlinearity inherent in disordered voice productions from short and noisy time series that are common in the clinical setting.

  7. Massage therapy has short-term benefits for people with common musculoskeletal disorders compared to no treatment: a systematic review

    Directory of Open Access Journals (Sweden)

    Diederik C Bervoets

    2015-07-01

    Full Text Available Question: Is massage therapy effective for people with musculoskeletal disorders compared to any other treatment or no treatment? Design: Systematic review of randomised clinical trials. Participants: People with musculoskeletal disorders. Interventions: Massage therapy (manual manipulation of the soft tissues as a stand-alone intervention. Outcome: The primary outcomes were pain and function. Results: The 26 eligible randomised trials involved 2565 participants. The mean sample size was 95 participants (range 16 to 579 per study; 10 studies were considered to be at low risk of bias. Overall, low-to-moderate-level evidence indicated that massage reduces pain in the short term compared to no treatment in people with shoulder pain and osteoarthritis of the knee, but not in those with low back pain or neck pain. Furthermore, low-to-moderate-level evidence indicated that massage improves function in the short term compared to no treatment in people with low back pain, knee arthritis or shoulder pain. Low-to-very-low-level evidence from single studies indicated no clear benefits of massage over acupuncture, joint mobilisation, manipulation or relaxation therapy in people with fibromyalgia, low back pain and general musculoskeletal pain. Conclusions: Massage therapy, as a stand-alone treatment, reduces pain and improves function compared to no treatment in some musculoskeletal conditions. When massage is compared to another active treatment, no clear benefit was evident. [Bervoets DC, Luijsterburg PAJ, Alessie JJN, Buijs MJ, Verhagen AP (2015 Massage therapy has short-term benefits for people with common musculoskeletal disorders compared to no treatment: a systematic review. Journal of Physiotherapy 61: 106–116

  8. Short-course versus long-course chemoradiation in rectal cancer--time to change strategies?

    Science.gov (United States)

    Palta, Manisha; Willett, Christopher G; Czito, Brian G

    2014-09-01

    There is significant debate regarding the optimal neoadjuvant regimen for resectable rectal cancer patients. Short-course radiotherapy, a standard approach throughout most of northern Europe, is generally defined as 25 Gy in 5 fractions over the course of 1 week without the concurrent administration of chemotherapy. Long-course radiotherapy is typically defined as 45 to 50.4 Gy in 25-28 fractions with the administration of concurrent 5-fluoropyrimidine-based chemotherapy and is the standard approach in other parts of Europe and the United States. At present, two randomized trials have compared outcomes for short course radiotherapy with long-course chemoradiation showing no difference in respective study endpoints. Late toxicity data are lacking given limited follow-up. Although the ideal neoadjuvant regimen is controversial, our current bias is long-course chemoradiation to treat patients with locally advanced, resectable rectal cancer.

  9. The time of onset of abnormal calcification in spondylometaepiphyseal dysplasia, short limb-abnormal calcification type

    Energy Technology Data Exchange (ETDEWEB)

    Tueysuez, Beyhan [Istanbul University, Department of Pediatric Genetics, Cerrahpasa Medical School, Istanbul (Turkey); Gazioglu, Nurperi [Istanbul University, Department of Neurosurgery, Cerrahpasa Medical School, Istanbul (Turkey); Uenguer, Savas [Istanbul University, Department of Pediatric Radiology, Cerrahpasa Medical School, Istanbul (Turkey); Aji, Dolly Yafet [Istanbul University, Department of Pediatrics, Cerrahpasa Medical School, Istanbul (Turkey); Tuerkmen, Seval [Istanbul University, Department of Pediatric Genetics, Cerrahpasa Medical School, Istanbul (Turkey); Universitatsklinikum Berlin, Charite Virchow-Klinik, Berlin (Germany)

    2009-01-15

    A 1-month-old boy with shortness of extremities on prenatal US was referred to our department with a provisional diagnosis of achondroplasia. His height was normal but he had short extremities and platyspondyly, premature carpal epiphyses on both hands, and short tubular bones with irregular metaphyses on radiographs. Re-evaluation of the patient at the age of 1 year revealed very short height and premature calcification of the costal cartilages and epiphyses. Spondylometaepiphyseal dysplasia (SMED), short limb-abnormal calcification type was diagnosed. This condition is a very rare autosomal recessively inherited disorder, and most of the patients die in early childhood due to neurological involvement. At the age of 2 years and 5 months, a CT scan showed narrowing of the cervical spinal canal. One month later he died suddenly because of spinal cord injury. In conclusion early diagnosis is very important because the recurrence risk is high and patients may die due to early neurological complications. The time of onset of abnormal calcifications, a diagnostic finding of the disease, is at the age of around 1 year in most patients. When abnormal calcifications are not yet present, but radiological changes associated with SMED are present, this rare disease must be considered. (orig.)

  10. The time of onset of abnormal calcification in spondylometaepiphyseal dysplasia, short limb-abnormal calcification type

    International Nuclear Information System (INIS)

    Tueysuez, Beyhan; Gazioglu, Nurperi; Uenguer, Savas; Aji, Dolly Yafet; Tuerkmen, Seval

    2009-01-01

    A 1-month-old boy with shortness of extremities on prenatal US was referred to our department with a provisional diagnosis of achondroplasia. His height was normal but he had short extremities and platyspondyly, premature carpal epiphyses on both hands, and short tubular bones with irregular metaphyses on radiographs. Re-evaluation of the patient at the age of 1 year revealed very short height and premature calcification of the costal cartilages and epiphyses. Spondylometaepiphyseal dysplasia (SMED), short limb-abnormal calcification type was diagnosed. This condition is a very rare autosomal recessively inherited disorder, and most of the patients die in early childhood due to neurological involvement. At the age of 2 years and 5 months, a CT scan showed narrowing of the cervical spinal canal. One month later he died suddenly because of spinal cord injury. In conclusion early diagnosis is very important because the recurrence risk is high and patients may die due to early neurological complications. The time of onset of abnormal calcifications, a diagnostic finding of the disease, is at the age of around 1 year in most patients. When abnormal calcifications are not yet present, but radiological changes associated with SMED are present, this rare disease must be considered. (orig.)

  11. New serial time codes for seismic short period and long period data acquisition systems

    International Nuclear Information System (INIS)

    Kolvankar, V.G.; Rao, D.S.

    1988-01-01

    This paper discusses a new time code for time indexing multichannel short period (1 to 25 hz) seismic event data recorded on a single track of magnetic tape in digital format and discusses its usefulness in contrast to Vela time code used in continuous analog multichannel data recording system on multitrack instrumentation tape deck. This paper also discusses another time code, used for time indexing of seismic long period (DC to 2.5 seconds) multichannel data recorded on a single track of magnetic tape in digital format. The time code decoding and display system developed to provide quick access to any desired portion of the tape in both data recording and repro duce system is also discussed. (author). 7 figs

  12. Comparing the mannitol-egg yolk-polymyxin agar plating method with the three-tube most-probable-number method for enumeration of Bacillus cereus spores in raw and high-temperature, short-time pasteurized milk.

    Science.gov (United States)

    Harper, Nigel M; Getty, Kelly J K; Schmidt, Karen A; Nutsch, Abbey L; Linton, Richard H

    2011-03-01

    The U.S. Food and Drug Administration's Bacteriological Analytical Manual recommends two enumeration methods for Bacillus cereus: (i) standard plate count method with mannitol-egg yolk-polymyxin (MYP) agar and (ii) a most-probable-number (MPN) method with tryptic soy broth (TSB) supplemented with 0.1% polymyxin sulfate. This study compared the effectiveness of MYP and MPN methods for detecting and enumerating B. cereus in raw and high-temperature, short-time pasteurized skim (0.5%), 2%, and whole (3.5%) bovine milk stored at 4°C for 96 h. Each milk sample was inoculated with B. cereus EZ-Spores and sampled at 0, 48, and 96 h after inoculation. There were no differences (P > 0.05) in B. cereus populations among sampling times for all milk types, so data were pooled to obtain overall mean values for each treatment. The overall B. cereus population mean of pooled sampling times for the MPN method (2.59 log CFU/ml) was greater (P milk samples ranged from 2.36 to 3.46 and 2.66 to 3.58 log CFU/ml for inoculated milk treatments for the MYP plate count and MPN methods, respectively, which is below the level necessary for toxin production. The MPN method recovered more B. cereus, which makes it useful for validation research. However, the MYP plate count method for enumeration of B. cereus also had advantages, including its ease of use and faster time to results (2 versus 5 days for MPN).

  13. Optimal filtering of dynamics in short-time features for music organization

    DEFF Research Database (Denmark)

    Arenas-García, Jerónimo; Larsen, Jan; Hansen, Lars Kai

    2006-01-01

    There is an increasing interest in customizable methods for organizing music collections. Relevant music characterization can be obtained from short-time features, but it is not obvious how to combine them to get useful information. In this work, a novel method, denoted as the Positive Constrained...... Orthonormalized Partial Least Squares (POPLS), is proposed. Working on the periodograms of MFCCs time series, this supervised method finds optimal filters which pick up the most discriminative temporal information for any music organization task. Two examples are presented in the paper, the first being a simple...... proof-of-concept, where an altosax with and without vibrato is modelled. A more complex \\$11\\$ music genre classification setup is also investigated to illustrate the robustness and validity of the proposed method on larger datasets. Both experiments showed the good properties of our method, as well...

  14. Short-time action electric generators to power physical devices

    International Nuclear Information System (INIS)

    Glebov, I.A.; Kasharskij, Eh.G.; Rutberg, F.G.; Khutoretskij, G.M.

    1982-01-01

    Requirements to be met by power-supply sources of the native electrophysical facilities have been analyzed and trends in designing foreign electric machine units of short-time action have been considered. Specifications of a generator, manufactured in the form of synchronous bipolar turbogenerator with an all-forged rotor with indirect air cooling of the rotor and stator windings are presented. Front parts of the stator winding are additionally fixed using glass-textolite rings, brackets and gaskets. A flywheel, manufactured in the form of all-forged steel cylinder is joined directly with the generator rotor by means of a half-coupling. An acceleration asynchronous engine with a phase rotor of 4 MW nominal capacity is located on the opposite side of the flywheel. The generator peak power is 242 MVxA; power factor = 0.9; energy transferred to the load 5per 1 pulse =00 MJ; the flywheel weight 81 t

  15. Nonequilibrium Physics at Short Time Scales: Formation of Correlations

    International Nuclear Information System (INIS)

    Peliti, L

    2005-01-01

    It is a happy situation when similar concepts and theoretical techniques can be applied to widely different physical systems because of a deep similarity in the situations being studied. The book illustrates this well; it focuses on the description of correlations in quantum systems out of equilibrium at very short time scales, prompted by experiments with short laser pulses in semiconductors, and in complex reactions in heavy nuclei. In both cases the experiments are characterized by nonlinear dynamics and by strong correlations out of equilibrium. In some systems there are also important finite-size effects. The book comprises several independent contributions of moderate length, and I sometimes felt that a more intensive effort in cross-coordination of the different contributions could have been of help. It is divided almost equally between theory and experiment. In the theoretical part, there is a thorough discussion both of the kinematic aspects (description of correlations) and the dynamical ones (evaluation of correlations). The experimental part is naturally divided according to the nature of the system: the interaction of pulsed lasers with matter on the one hand, and the correlations in finite-size systems (nanoparticles and nuclei) on the other. There is also a discussion on the dynamics of superconductors, a subject currently of great interest. Although an effort has been made to keep each contribution self-contained, I must admit that reading level is uneven. However, there are a number of thorough and stimulating contributions that make this book a useful introduction to the topic at the level of graduate students or researchers acquainted with quantum statistical mechanics. (book review)

  16. A voxel-based investigation for MRI-only radiotherapy of the brain using ultra short echo times

    DEFF Research Database (Denmark)

    Edmund, Jens Morgenthaler; Kjer, Hans Martin; Van Leemput, Koen

    2014-01-01

    including or excluding additional spatial information. Approach 3 used a statistical regression correlating MRI voxels with their corresponding CT voxels. A similar photon and proton treatment plan was generated for a target positioned between the nasal cavity and the brainstem for all patients. The CT...... receiving cranial irradiation, each containing a co-registered MRI and CT scan, were included. An ultra short echo time MRI sequence for bone visualization was used. Six methods were investigated for three popular types of voxel-based approaches; (1) threshold-based segmentation, (2) Bayesian segmentation...... significantly better than the threshold and Bayesian segmentation methods (excluding spatial information). All methods agreed significantly better with CT than a reference water MRI comparison. The mean dosimetric deviation for photons and protons compared to the CT was about 2% and highest in the gradient dose...

  17. Time does not cause forgetting in short-term serial recall.

    Science.gov (United States)

    Lewandowsky, Stephan; Duncan, Matthew; Brown, Gordon D A

    2004-10-01

    Time-based theories expect memory performance to decline as the delay between study and recall of an item increases. The assumption of time-based forgetting, central to many models of serial recall, underpins their key behaviors. Here we compare the predictions of time-based and event-based models by simulation and test them in two experiments using a novel manipulation of the delay between study and retrieval. Participants were trained, via corrective feedback, to recall at different speeds, thus varying total recall time from 6 to 10 sec. In the first experiment, participants used the keyboard to enter their responses but had to repeat a word (called the suppressor) aloud during recall to prevent rehearsal. In the second experiment, articulation was again required, but recall was verbal and was paced by the number of repetitions of the suppressor in between retrieval of items. In both experiments, serial position curves for all retrieval speeds overlapped, and output time had little or no effect. Comparative evaluation of a time-based and an event-based model confirmed that these results present a particular challenge to time-based approaches. We conclude that output interference, rather than output time, is critical in serial recall.

  18. Spectral phase encoding of ultra-short optical pulse in time domain for OCDMA application.

    Science.gov (United States)

    Wang, Xu; Wada, Naoya

    2007-06-11

    We propose a novel reconfigurable time domain spectral phase encoding (SPE) scheme for coherent optical code-division-multiple-access application. In the proposed scheme, the ultra-short optical pulse is stretched by dispersive device and the SPE is done in time domain using high speed phase modulator. The time domain SPE scheme is robust to wavelength drift of the light source and is very flexible and compatible with the fiber optical system. Proof-of-principle experiments of encoding with 16-chip, 20 GHz/chip binary-phase-shift-keying codes and 1.25 Gbps data transmission have been successfully demonstrated together with an arrayed-wave-guide decoder.

  19. Short-time home coming project in evacuation zone

    International Nuclear Information System (INIS)

    Tatsuzaki, Hideo

    2011-01-01

    Accident at Fukushima Daiichi Nuclear Power Plants (NPPs) forced neighboring residents to evacuate, and evacuation zone (20 km radius from NPPs) was defined as highly contaminated and designated as no-entry zones. Residents had been obliged to live a refugee life for a longer period than expected. Short-time home coming project was initiated according to their requests. They came to the meeting place called transfer place (20 - 30 km radius from NPPs), wore protective clothing and personal dosimeter with having drinking water and came home in evacuation zone with staffs by bus. Their healthcare management professionals were fully prepared for emergency. After collecting necessary articles at home within two hours, they returned to the meeting place by bus for screening and dressing, and went back to refuge house. If screening data were greater than 13 kcpm using GM counters, partial body decontamination had been conducted by wiping and if greater than 100 kcpm, whole body decontamination was requested but not conducted. Dose rate of residents and staffs was controlled less than 1 mSv, which was alarm level of personal dosimeter. Stable iodine was prepared but actually not used. (T. Tanaka)

  20. A Distributed Web-based Solution for Ionospheric Model Real-time Management, Monitoring, and Short-term Prediction

    Science.gov (United States)

    Kulchitsky, A.; Maurits, S.; Watkins, B.

    2006-12-01

    provide inputs for the next ionospheic model time step and then stored in a MySQL database as the first part of the time-specific record. The RMM then performs synchronization of the input times with the current model time, prepares a decision on initialization for the next model time step, and monitors its execution. Then, as soon as the model completes computations for the next time step, RMM visualizes the current model output into various short-term (about 1-2 hours) forecasting products and compares prior results with available ionospheric measurements. The RMM places prepared images into the MySQL database, which can be located on a different computer node, and then proceeds to the next time interval continuing the time-loop. The upper-level interface of this real-time system is the a PHP-based Web site (http://www.arsc.edu/SpaceWeather/new). This site provides general information about the Earth polar and adjacent mid-latitude ionosphere, allows for monitoring of the current developments and short-term forecasts, and facilitates access to the comparisons archive stored in the database.

  1. Performance evaluation of the short-time objective intelligibility measure with different band importance functions

    DEFF Research Database (Denmark)

    Heidemann Andersen, Asger; de Haan, Jan Mark; Tan, Zheng-Hua

    performance measures: root-mean-squared-error, Pearson correlation, and Kendall rank correlation. The results show substantially improved performance when fitting and evaluating on the same dataset. However, this advantage does not necessarily subsist when fitting and evaluating on different datasets. When...... with a filter bank, 2) envelopes are extracted from each band, 3) the temporal correlation between clean and degraded envelopes is computed in short time segments, and 4) the correlation is averaged across time and frequency bands to obtain the final output. An unusual choice in the design of the STOI measure...

  2. Short-term results of a prospective randomized evaluator blinded multicenter study comparing TVT and TVT-Secur.

    Science.gov (United States)

    Andrada Hamer, Maria; Larsson, Per-Göran; Teleman, Pia; Etén-Bergqvist, Christina; Persson, Jan

    2011-07-01

    The aim of this prospective randomized multicenter study was to compare TVT (tension-free vaginal tape) with TVT-Secur in terms of efficacy and safety. We set out to enrol 280 stress incontinent women with a half time interim analysis of short-term cure and a continuous registration of adverse events. Of 133 randomized women, 126 were operated and 123 (TVT n = 62, TVT-Secur n = 61) available for 2 months follow-up. No significant differences were found between groups regarding demographics or grade of incontinence. At 2 months follow-up, subjective cure rate following TVT-Secur was significantly lower than for TVT (72% and 92%, respectively, p = 0.01). Three major complications occurred in the TVT-Secur group: tape erosion into the urethra, a tape inadvertently placed inside the bladder, and an immediate postoperative bleeding from the corona mortis. No major complications occurred in the TVT group. No significant differences were found between groups regarding perioperative bleeding, hospital stay, urge symptoms, or postoperative urinary tract infections. Median time for surgery was 13 and 22 min for TVT-Secur and TVT, respectively (p TVT-Secur procedure had a significantly lower subjective cure rate than the retropubic TVT procedure. Due to this, in addition to three serious complications in the TVT-Secur group, we decided to stop further enrolment after the interim analysis. We discourage from further use of the TVT-Secur.

  3. Critical dynamics of the Potts model: short-time Monte Carlo simulations

    International Nuclear Information System (INIS)

    Silva, Roberto da; Drugowich de Felicio, J.R.

    2004-01-01

    We calculate the new dynamic exponent θ of the 4-state Potts model, using short-time simulations. Our estimates θ1=-0.0471(33) and θ2=-0.0429(11) obtained by following the behavior of the magnetization or measuring the evolution of the time correlation function of the magnetization corroborate the conjecture by Okano et al. [Nucl. Phys. B 485 (1997) 727]. In addition, these values agree with previous estimate of the same dynamic exponent for the two-dimensional Ising model with three-spin interactions in one direction, that is known to belong to the same universality class as the 4-state Potts model. The anomalous dimension of initial magnetization x0=zθ+β/ν is calculated by an alternative way that mixes two different initial conditions. We have also estimated the values of the static exponents β and ν. They are in complete agreement with the pertinent results of the literature

  4. Long Short-Term Memory Neural Networks for Online Disturbance Detection in Satellite Image Time Series

    Directory of Open Access Journals (Sweden)

    Yun-Long Kong

    2018-03-01

    Full Text Available A satellite image time series (SITS contains a significant amount of temporal information. By analysing this type of data, the pattern of the changes in the object of concern can be explored. The natural change in the Earth’s surface is relatively slow and exhibits a pronounced pattern. Some natural events (for example, fires, floods, plant diseases, and insect pests and human activities (for example, deforestation and urbanisation will disturb this pattern and cause a relatively profound change on the Earth’s surface. These events are usually referred to as disturbances. However, disturbances in ecosystems are not easy to detect from SITS data, because SITS contain combined information on disturbances, phenological variations and noise in remote sensing data. In this paper, a novel framework is proposed for online disturbance detection from SITS. The framework is based on long short-term memory (LSTM networks. First, LSTM networks are trained by historical SITS. The trained LSTM networks are then used to predict new time series data. Last, the predicted data are compared with real data, and the noticeable deviations reveal disturbances. Experimental results using 16-day compositions of the moderate resolution imaging spectroradiometer (MOD13Q1 illustrate the effectiveness and stability of the proposed approach for online disturbance detection.

  5. Time-resolved plasma spectroscopy of thin foils heated by a relativistic-intensity short-pulse laser

    International Nuclear Information System (INIS)

    Audebert, P.; Gauthier, J.-C.; Shepherd, R.; Fournier, K.B.; Price, D.; Lee, R.W.; Springer, P.; Peyrusse, O.; Klein, L.

    2002-01-01

    Time-resolved K-shell x-ray spectra are recorded from sub-100 nm aluminum foils irradiated by 150-fs laser pulses at relativistic intensities of Iλ 2 =2x10 18 W μm 2 /cm 2 . The thermal penetration depth is greater than the foil thickness in these targets so that uniform heating takes place at constant density before hydrodynamic motion occurs. The high-contrast, high-intensity laser pulse, broad spectral band, and short time resolution utilized in this experiment permit a simplified interpretation of the dynamical evolution of the radiating matter. The observed spectrum displays two distinct phases. At early time, ≤500 fs after detecting target emission, a broad quasicontinuous spectral feature with strong satellite emission from multiply excited levels is seen. At a later time, the He-like resonance line emission is dominant. The time-integrated data is in accord with previous studies with time resolution greater than 1 ps. The early time satellite emission is shown to be a signature of an initial large area, high density, low-temperature plasma created in the foil by fast electrons accelerated by the intense radiation field in the laser spot. We conclude that, because of this early time phenomenon and contrary to previous predictions, a short, high-intensity laser pulse incident on a thin foil does not create a uniform hot and dense plasma. The heating mechanism has been studied as a function of foil thickness, laser pulse length, and intensity. In addition, the spectra are found to be in broad agreement with a hydrodynamic expansion code postprocessed by a collisional-radiative model based on superconfiguration average rates and on the unresolved transition array formalism

  6. Short- and long-run time-of-use price elasticities in Swiss residential electricity demand

    International Nuclear Information System (INIS)

    Filippini, Massimo

    2011-01-01

    This paper presents an empirical analysis on the residential demand for electricity by time-of-day. This analysis has been performed using aggregate data at the city level for 22 Swiss cities for the period 2000-2006. For this purpose, we estimated two log-log demand equations for peak and off-peak electricity consumption using static and dynamic partial adjustment approaches. These demand functions were estimated using several econometric approaches for panel data, for example LSDV and RE for static models, and LSDV and corrected LSDV estimators for dynamic models. The attempt of this empirical analysis has been to highlight some of the characteristics of the Swiss residential electricity demand. The estimated short-run own price elasticities are lower than 1, whereas in the long-run these values are higher than 1. The estimated short-run and long-run cross-price elasticities are positive. This result shows that peak and off-peak electricity are substitutes. In this context, time differentiated prices should provide an economic incentive to customers so that they can modify consumption patterns by reducing peak demand and shifting electricity consumption from peak to off-peak periods. - Highlights: → Empirical analysis on the residential demand for electricity by time-of-day. → Estimators for dynamic panel data. → Peak and off-peak residential electricity are substitutes.

  7. Spectrogram analysis of selected tremor signals using short-time Fourier transform and continuous wavelet transform

    Energy Technology Data Exchange (ETDEWEB)

    Bartosch, T. [Erlanger-Nuernberg Univ., Erlanger (Germany). Lehrstul fuer Nachrichtentechnik I; Seidl, D. [Seismologisches Zentralobservatorium Graefenberg, Erlanegen (Greece). Bundesanstalt fuer Geiwissenschaften und Rohstoffe

    1999-06-01

    Among a variety of spectrogram methods short-time Fourier transform (STFT) and continuous wavelet transform (CWT) were selected to analyse transients in non-stationary signals. Depending on the properties of the tremor signals from the volcanos Mt. Stromboli, Mt. Semeru and Mt. Pinatubo were analyzed using both methods. The CWT can also be used to extend the definition of coherency into a time-varying coherency spectrogram. An example is given using array data from the volcano Mt. Stromboli (Italy).

  8. Primary evaluation of the radon situation in dwellings in Saxony by long-time integrating measurements, comparison of the results with short-time measurements and determination of the radon activity concentration in the ground of the land; Erstbewertung zur Radonsituation von Haeusern im Freistaat Sachsen mittels langzeitintegrierenden Messungen, Vergleich der Ergebnisse mit Kurzzeitmessungen und Erfassung der Radon-Aktivitaetskonzentration in der Bodenluft der Grundstuecke

    Energy Technology Data Exchange (ETDEWEB)

    Alisch-Mark, M.; Keck, D.; Preusse, W.; Taube, A.; Busch, H.; Heinrich, T. [Staatliche Betriebsgesellschaft fuer Umwelt und Landwirtschaft, Sachsen (Germany)

    2016-07-01

    A measurement program was carried out for primary evaluation of dwellings in terms of radon situation. Short-time measurements were compared with annual averages and checked for their suitability for forecasting the annual averages. In 89% of the cases studied, the average annual values could be predicted by short-time measurements, differences were observed depending on the date of the short-time measure. In addition, radon activity concentrations were determined in the soil air in the ground and compared with the expected areas of forecasting map of Saxony. Discrepancies were found primarily in areas which are marked by a smallscale geology. The data obtained showed that the geogenic radon potential and the year of construction of the house represent factors influencing the probability of exceedance of the reference value of 300 Bq/m{sup 3}.

  9. Desflurane Allows for a Faster Emergence when Compared to Sevoflurane Without Affecting the Baseline Cognitive Recovery Time.

    Directory of Open Access Journals (Sweden)

    Joseph G. Werner

    2015-10-01

    Full Text Available Aims, We compared the effect of desflurane and sevoflurane on anesthesia recovery time in patients undergoing urological cystoscopic surgery. The Short Orientation Memory Concentration Test (SOMCT measured and compared cognitive impairment between groups and coughing was assessed throughout the anesthetic.Methods and Materials, This investigation included 75 ambulatory patients. Patients were randomized to receive either desflurane or sevoflurane. Inhalational anesthetics were discontinued after removal of the cystoscope and once repositioning of the patient was final. Coughing assessment and awakening time from anesthesia were assessed by a blinded observer.Statistical analysis used: Statistical analysis was performed by using t-test for parametric variables and Mann-Whitney U test for nonparametric variables. Results, The primary endpoint, mean time to eye-opening, was 5.0±2.5 minutes for desflurane, and 7.9±4.1 minutes for sevoflurane (p <0.001. There were no significant differences in time to SOMCT recovery (p=0.109, overall time spent in the post anesthesia care unit (p=0.924 or time to discharge (p=0.363. Median time until readiness for discharge was nine minutes in the desflurane group, while the sevoflurane group had a median time of 20 minutes (p=0.020. The overall incidence of coughing during the perioperative period was significantly higher in the desflurane (p=0.030. Conclusions, We re-confirmed that patients receiving desflurane had a faster emergence and met the criteria to be discharged from the post anesthesia care unit earlier. No difference was found in time to return to baseline cognition between desflurane and sevoflurane.

  10. Measurement of radon-222 concentration in environment sampled within short time using charcoal detector

    International Nuclear Information System (INIS)

    Yamasaki, Tadashi; Sekiyama, Shigenobu; Tokin, Mina; Nakayasu, Yumiko; Watanabe, Tamaki.

    1994-01-01

    The concentration of 222 Rn in air sampled within a very short period of time was measured using activated charcoal as the adsorber. The detector is the plastic canister containing mixture of the activated charcoal and the silica gel. The radon gas was adsorbed in the charcoal in the radon chamber at the temperature of 25degC. A little amount of liquid scintillation cocktail was added into the vial of liquid scintillation counter with the canister. The radon in the charcoal was extracted in the liquid scintillation cocktail. Alpha particles emitted from radon and its daughter nuclei in the cocktail were detected using the liquid scintillation counter. Present method has advantages of not only short sampling time of air but also adsorption of radon in charcoal under a constant temperature. The concentration of radon in air down to 2 Bq/m 3 could be detected. A kinetic model for adsorption of radon in the charcoal is also presented. The ratio of radon concentration in the charcoal to that in air under the equilibrium state of adsorption was estimated to be from 6.1 to 6.8 m 3 /kg at the temperature of 25degC. (author)

  11. Verification of short lead time forecast models: applied to Kp and Dst forecasting

    Science.gov (United States)

    Wintoft, Peter; Wik, Magnus

    2016-04-01

    In the ongoing EU/H2020 project PROGRESS models that predicts Kp, Dst, and AE from L1 solar wind data will be used as inputs to radiation belt models. The possible lead times from L1 measurements are shorter (10s of minutes to hours) than the typical duration of the physical phenomena that should be forecast. Under these circumstances several metrics fail to single out trivial cases, such as persistence. In this work we explore metrics and approaches for short lead time forecasts. We apply these to current Kp and Dst forecast models. This project has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement No 637302.

  12. Highly comparative time-series analysis: the empirical structure of time series and their methods.

    Science.gov (United States)

    Fulcher, Ben D; Little, Max A; Jones, Nick S

    2013-06-06

    The process of collecting and organizing sets of observations represents a common theme throughout the history of science. However, despite the ubiquity of scientists measuring, recording and analysing the dynamics of different processes, an extensive organization of scientific time-series data and analysis methods has never been performed. Addressing this, annotated collections of over 35 000 real-world and model-generated time series, and over 9000 time-series analysis algorithms are analysed in this work. We introduce reduced representations of both time series, in terms of their properties measured by diverse scientific methods, and of time-series analysis methods, in terms of their behaviour on empirical time series, and use them to organize these interdisciplinary resources. This new approach to comparing across diverse scientific data and methods allows us to organize time-series datasets automatically according to their properties, retrieve alternatives to particular analysis methods developed in other scientific disciplines and automate the selection of useful methods for time-series classification and regression tasks. The broad scientific utility of these tools is demonstrated on datasets of electroencephalograms, self-affine time series, heartbeat intervals, speech signals and others, in each case contributing novel analysis techniques to the existing literature. Highly comparative techniques that compare across an interdisciplinary literature can thus be used to guide more focused research in time-series analysis for applications across the scientific disciplines.

  13. The "Nursing Home Compare" measure of urinary/fecal incontinence: cross-sectional variation, stability over time, and the impact of case mix.

    Science.gov (United States)

    Li, Yue; Schnelle, John; Spector, William D; Glance, Laurent G; Mukamel, Dana B

    2010-02-01

    To assess the impact of facility case mix on cross-sectional variations and short-term stability of the "Nursing Home Compare" incontinence quality measure (QM) and to determine whether multivariate risk adjustment can minimize such impacts. Retrospective analyses of the 2005 national minimum data set (MDS) that included approximately 600,000 long-term care residents in over 10,000 facilities in each quarterly sample. Mixed logistic regression was used to construct the risk-adjusted QM (nonshrinkage estimator). Facility-level ordinary least-squares models and adjusted R(2) were used to estimate the impact of case mix on cross-sectional and short-term longitudinal variations of currently published and risk-adjusted QMs. At least 50 percent of the cross-sectional variation and 25 percent of the short-term longitudinal variation of the published QM are explained by facility case mix. In contrast, the cross-sectional and short-term longitudinal variations of the risk-adjusted QM are much less susceptible to case-mix variations (adjusted R(2)case-mix variations across facilities and over time, and therefore it may be biased. This issue can be largely addressed by multivariate risk adjustment using risk factors available in the MDS.

  14. libgapmis: extending short-read alignments.

    Science.gov (United States)

    Alachiotis, Nikolaos; Berger, Simon; Flouri, Tomáš; Pissis, Solon P; Stamatakis, Alexandros

    2013-01-01

    A wide variety of short-read alignment programmes have been published recently to tackle the problem of mapping millions of short reads to a reference genome, focusing on different aspects of the procedure such as time and memory efficiency, sensitivity, and accuracy. These tools allow for a small number of mismatches in the alignment; however, their ability to allow for gaps varies greatly, with many performing poorly or not allowing them at all. The seed-and-extend strategy is applied in most short-read alignment programmes. After aligning a substring of the reference sequence against the high-quality prefix of a short read--the seed--an important problem is to find the best possible alignment between a substring of the reference sequence succeeding and the remaining suffix of low quality of the read--extend. The fact that the reads are rather short and that the gap occurrence frequency observed in various studies is rather low suggest that aligning (parts of) those reads with a single gap is in fact desirable. In this article, we present libgapmis, a library for extending pairwise short-read alignments. Apart from the standard CPU version, it includes ultrafast SSE- and GPU-based implementations. libgapmis is based on an algorithm computing a modified version of the traditional dynamic-programming matrix for sequence alignment. Extensive experimental results demonstrate that the functions of the CPU version provided in this library accelerate the computations by a factor of 20 compared to other programmes. The analogous SSE- and GPU-based implementations accelerate the computations by a factor of 6 and 11, respectively, compared to the CPU version. The library also provides the user the flexibility to split the read into fragments, based on the observed gap occurrence frequency and the length of the read, thereby allowing for a variable, but bounded, number of gaps in the alignment. We present libgapmis, a library for extending pairwise short-read alignments. We

  15. Comparative study of short- and long-term indoor radon measurements

    Energy Technology Data Exchange (ETDEWEB)

    Al-Jarallah, M.I. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)], E-mail: mibrahim@kfupm.edu.sa; Fazal-ur-Rehman,; Abdalla, Khalid [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2008-08-15

    Short-term indoor radon measurements are used widely. Therefore, it is interesting to find out a correlation between these measurements and long-term measurements which reflect a better average radon concentration of individual measurement. To find the correlation between the two measurements of indoor radon concentrations at low radon levels, a study was carried out at 34 locations of King Fahd University of Petroleum and Minerals (KFUPM), Dhahran, Saudi Arabia using active and passive methods. In the short-term active method, a radon gas analyzer (AlphaGUARD) was used for a duration of 24 h in each measurement. In the long-term passive method, CR-39 based radon dosimeters were utilized for a period of 6 months, from January 2006 to June 2006. The short-term active measurements showed that the average, minimum and maximum radon concentrations were 19, 8 and 58Bqm{sup -3}, respectively, with a standard deviation of 8.6Bqm{sup -3}. The long-term passive measurements showed that the average, minimum and maximum radon concentrations were 25, 10 and 67Bqm{sup -3}, respectively, with a standard deviation of 12Bqm{sup -3}. The two measurements showed a poor correlation (R{sup 2}=0.38). The long-term measurements showed on the average higher concentrations by a factor of 1.3.

  16. Stimulated brillouin backscatter of a short-pulse laser

    International Nuclear Information System (INIS)

    Hinkel, D.E.; Williams, E.A.; Berger, R.L.

    1994-01-01

    Stimulated Brillouin backscattering (SBBS) from a short-pulse laser, where the pulse length is short compared to the plasma length, is found to be qualitatively different than in the long pulse regime, where the pulse length is long compared to the plasma length. We find that after an initial transient of order the laser pulse length transit time, the instability reaches a steady state in the variables x' = x - V g t, t' = t, where V g is the pulse group velocity. In contrast, SBBS in a long pulse can be absolutely unstable and grows indefinitely, or until nonlinearities intervene. We find that the motion of the laser pulse induces Doppler related effects that substantially modify the backscattered spectrum at higher intensities, where the instability is strongly coupled (i.e. , has a growth rate large compared to the ion acoustic frequency)

  17. Increasing Short-Stay Unplanned Hospital Admissions among Children in England; Time Trends Analysis ’97–‘06

    Science.gov (United States)

    Saxena, Sonia; Bottle, Alex; Gilbert, Ruth; Sharland, Mike

    2009-01-01

    Background Timely care by general practitioners in the community keeps children out of hospital and provides better continuity of care. Yet in the UK, access to primary care has diminished since 2004 when changes in general practitioners' contracts enabled them to ‘opt out’ of providing out-of-hours care and since then unplanned pediatric hospital admission rates have escalated, particularly through emergency departments. We hypothesised that any increase in isolated short stay admissions for childhood illness might reflect failure to manage these cases in the community over a 10 year period spanning these changes. Methods and Findings We conducted a population based time trends study of major causes of hospital admission in children 2 days. By 2006, 67.3% of all unplanned admissions were isolated short stays <2 days. The increases in admission rates were greater for common non-infectious than infectious causes of admissions. Conclusions Short stay unplanned hospital admission rates in young children in England have increased substantially in recent years and are not accounted for by reductions in length of in-hospital stay. The majority are isolated short stay admissions for minor illness episodes that could be better managed by primary care in the community and may be evidence of a failure of primary care services. PMID:19829695

  18. Time perspective in hereditary cancer: psychometric properties of a short form of the Zimbardo Time Perspective Inventory in a community and clinical sample.

    Science.gov (United States)

    Wakefield, Claire E; Homewood, Judi; Taylor, Alan; Mahmut, Mehmet; Meiser, Bettina

    2010-10-01

    We aimed to assess the psychometric properties of a 25-item short form of the Zimbardo Time Perspective Inventory in a community sample (N = 276) and in individuals with a strong family history of cancer, considering genetic testing for cancer risk (N = 338). In the community sample, individuals with high past-negative or present-fatalistic scores had higher levels of distress, as measured by depression, anxiety, and aggression. Similarly, in the patient sample, past-negative time perspective was positively correlated with distress, uncertainty, and postdecision regret when making a decision about genetic testing. Past-negative-oriented individuals were also more likely to be undecided about, or against, genetic testing. Hedonism was associated with being less likely to read the educational materials they received at their clinic, and fatalism was associated with having lower knowledge levels about genetic testing. The assessment of time perspective in individuals at increased risk of cancer can provide valuable clinical insights. However, further investigation of the psychometric properties of the short form of this scale is warranted, as it did not meet the currently accepted criteria for psychometric validation studies.

  19. Comparing short forms of the Social Interaction Anxiety Scale and the Social Phobia Scale.

    Science.gov (United States)

    Carleton, R Nicholas; Thibodeau, Michel A; Weeks, Justin W; Teale Sapach, Michelle J N; McEvoy, Peter M; Horswill, Samantha C; Heimberg, Richard G

    2014-12-01

    The Social Interaction Anxiety Scale (SIAS) and the Social Phobia Scale (SPS; Mattick & Clarke, 1998) are companion scales developed to measure anxiety in social interaction and performance situations, respectively. The measures have strong discriminant and convergent validity; however, their factor structures remain debated, and furthermore, the combined administration length (i.e., 39 items) can be prohibitive for some settings. There have been 4 attempts to assess the factor structures of the scales and reduce the item content: the 14-item Social Interaction Phobia Scale (SIPS; Carleton et al., 2009), the 12-item SIAS-6/SPS-6 (Peters, Sunderland, Andrews, Rapee, & Mattick, 2012), the 21-item abbreviated SIAS/SPS (ASIAS/ASPS; Kupper & Denollet, 2012), and the 12-item Readability SIAS and SPS (RSIAS/RSPS; Fergus, Valentiner, McGrath, Gier-Lonsway, & Kim, 2012). The current study compared the short forms on (a) factor structure, (b) ability to distinguish between clinical and non-clinical populations, (c) sensitivity to change following therapy, and (d) convergent validity with related measures. Participants included 3,607 undergraduate students (55% women) and 283 patients with social anxiety disorder (43% women). Results of confirmatory factor analyses, sensitivity analyses, and correlation analyses support the robust utility of items in the SIPS and the SPS-6 and SIAS-6 relative to the other short forms; furthermore, the SIPS and the SPS-6 and SIAS-6 were also supported by convergent validity analyses within the undergraduate sample. The RSIAS/RSPS and the ASIAS/ASPS were least supported, based on the current results and the principle of parsimony. Accordingly, researchers and clinicians should consider carefully which of the short forms will best suit their needs. (c) 2014 APA, all rights reserved.

  20. Effects of elevated CO[sub 2] on time of flowering in four short-day and four long-day species

    Energy Technology Data Exchange (ETDEWEB)

    Reekie, J.Y.C.; Hicklenton, P.R. (Agriculture Canada Research Station, Kentiville, NS (Canada)); Reekie, E.G. (Acadia Univ., Wolfville, NS (Canada))

    1994-01-01

    A study was undertaken to determine if the effect of elevated CO[sub 2] on flowering phenology is a function of the photoperiodic response of the species involved. Four long-day plants, Achillea millefolium, Callistephus chinensis, Campanula isophylla, and Trachelium caeruleum, and four short-day plants, Dendranthema grandiflora, Kalanchoe blossfeldiana, Pharbitis nil, and Xanthium pensylvanicum, were grown under inductive photoperiods (9 h for short day and 17 h for long day) at either 350 or 1000 [mu]l/l CO[sub 2]. Time of visible flower bud formation, flower opening, and final plant biomass were assessed. Elevated CO[sub 2] advanced flower opening in all four long-day species and delayed flowering in all four short-day species. In the long-day species, the effect of CO[sub 2] was primarily on bud initiation; all four species formed buds earlier at high CO[sub 2]. Bud development, the difference in time between flower opening and bud initiation, was advanced in only one long-day species, Callistephus chinensis. Mixed results were obtained for the short-day species. Elevated CO[sub 2] exerted no effects on bud initiation but delayed bud development in Dendranthema and Kalanchoe. In Xanthium, bud initiation rather than bud development was delayed. Data on bud initiation and development were not obtained for Pharbitis. The negative effect of CO[sub 2] upon phenology in the short-day species was not associated with negative effects on growth. Elevated CO[sub 2] increased plant size in both long-day and short-day species. 26 refs., 4 tabs.

  1. Short-range correlations in an extended time-dependent mean-field theory

    International Nuclear Information System (INIS)

    Madler, P.

    1982-01-01

    A generalization is performed of the time-dependent mean-field theory by an explicit inclusion of strong short-range correlations on a level of microscopic reversibility relating them to realistic nucleon-nucleon forces. Invoking a least action principle for correlated trial wave functions, equations of motion for the correlation functions and the single-particle model wave function are derived in lowest order of the FAHT cluster expansion. Higher order effects as well as long-range correlations are consider only to the extent to which they contribute to the mean field via a readjusted phenomenological effective two-body interaction. The corresponding correlated stationary problem is investigated and appropriate initial conditions to describe a heavy ion reaction are proposed. The singleparticle density matrix is evaluated

  2. Polynomial Phase Estimation Based on Adaptive Short-Time Fourier Transform.

    Science.gov (United States)

    Jing, Fulong; Zhang, Chunjie; Si, Weijian; Wang, Yu; Jiao, Shuhong

    2018-02-13

    Polynomial phase signals (PPSs) have numerous applications in many fields including radar, sonar, geophysics, and radio communication systems. Therefore, estimation of PPS coefficients is very important. In this paper, a novel approach for PPS parameters estimation based on adaptive short-time Fourier transform (ASTFT), called the PPS-ASTFT estimator, is proposed. Using the PPS-ASTFT estimator, both one-dimensional and multi-dimensional searches and error propagation problems, which widely exist in PPSs field, are avoided. In the proposed algorithm, the instantaneous frequency (IF) is estimated by S-transform (ST), which can preserve information on signal phase and provide a variable resolution similar to the wavelet transform (WT). The width of the ASTFT analysis window is equal to the local stationary length, which is measured by the instantaneous frequency gradient (IFG). The IFG is calculated by the principal component analysis (PCA), which is robust to the noise. Moreover, to improve estimation accuracy, a refinement strategy is presented to estimate signal parameters. Since the PPS-ASTFT avoids parameter search, the proposed algorithm can be computed in a reasonable amount of time. The estimation performance, computational cost, and implementation of the PPS-ASTFT are also analyzed. The conducted numerical simulations support our theoretical results and demonstrate an excellent statistical performance of the proposed algorithm.

  3. Gamma spectrometric characterization of short cooling time nuclear spent fuels using hemispheric CdZnTe detectors

    CERN Document Server

    Lebrun, A; Szabó, J L; Arenas-Carrasco, J; Arlt, R; Dubreuil, A; Esmailpur-Kazerouni, K

    2000-01-01

    After years of cooling, nuclear spent fuel gamma emissions are mainly due to caesium isotopes which are emitters at 605, 662 and 796-801 keV. Extensive work has been done on such fuels using various CdTe or CdZnTe probes. When fuels have to be measured after short cooling time (during NPP outage) the spectrum is much more complex due to the important contributions of niobium and zirconium in the 700 keV range. For the first time in a nuclear power plant, four spent fuels of the Kozloduy VVER reactor no 4 were measured during outage, 37 days after shutdown of the reactor. In such conditions, good resolution is of particular interest, so a 20 mm sup 3 hemispheric crystal was used with a resolution better than 7 keV at 662 keV. This paper presents the experimental device and analyzes the results which show that CdZnTe commercially available detectors enabled us to perform a semi-quantitative determination of the burn-up after a short cooling time. In addition, it is discussed how a burn-up evolution code (CESAR)...

  4. Massage therapy has short-term benefits for people with common musculoskeletal disorders compared to no treatment: a systematic review.

    Science.gov (United States)

    Bervoets, Diederik C; Luijsterburg, Pim A J; Alessie, Jeroen J N; Buijs, Martijn J; Verhagen, Arianne P

    2015-07-01

    Is massage therapy effective for people with musculoskeletal disorders compared to any other treatment or no treatment? Systematic review of randomised clinical trials. People with musculoskeletal disorders. Massage therapy (manual manipulation of the soft tissues) as a stand-alone intervention. The primary outcomes were pain and function. The 26 eligible randomised trials involved 2565 participants. The mean sample size was 95 participants (range 16 to 579) per study; 10 studies were considered to be at low risk of bias. Overall, low-to-moderate-level evidence indicated that massage reduces pain in the short term compared to no treatment in people with shoulder pain and osteoarthritis of the knee, but not in those with low back pain or neck pain. Furthermore, low-to-moderate-level evidence indicated that massage improves function in the short term compared to no treatment in people with low back pain, knee arthritis or shoulder pain. Low-to-very-low-level evidence from single studies indicated no clear benefits of massage over acupuncture, joint mobilisation, manipulation or relaxation therapy in people with fibromyalgia, low back pain and general musculoskeletal pain. Massage therapy, as a stand-alone treatment, reduces pain and improves function compared to no treatment in some musculoskeletal conditions. When massage is compared to another active treatment, no clear benefit was evident. Copyright © 2015 Australian Physiotherapy Association. Published by Elsevier B.V. All rights reserved.

  5. Development of a system for real-time measurements of metabolite transport in plants using short-lived positron-emitting radiotracers

    Science.gov (United States)

    Kiser, Matthew R.

    Over the past 200 years, the Earth's atmospheric carbon dioxide (CO 2) concentration has increased by more than 35%, and climate experts predict that CO2 levels may double by the end of this century. Understanding the mechanisms of resource management in plants is fundamental for predicting how plants will respond to the increase in atmospheric CO 2. Plant productivity sustains life on Earth and is a principal component of the planet's system that regulates atmospheric CO2 concentration. As such, one of the central goals of plant science is to understand the regulatory mechanisms of plant growth in a changing environment. Short-lived positron-emitting radiotracer techniques provide time-dependent data that are critical for developing models of metabolite transport and resource distribution in plants and their microenvironments. To better understand the effects of environmental changes on resource transport and allocation in plants, we have developed a system for real-time measurements of rnetabolite transport in plants using short-lived positron-emitting radio-tracers. This thesis project includes the design, construction, and demonstration of the capabilities of this system for performing real-time measurements of metabolite transport in plants. The short-lived radiotracer system described in this dissertation takes advantage of the combined capabilities and close proximity of two research facilities at. Duke University: the Triangle Universities Nuclear Laboratory (TUNL) and the Duke University Phytotron, which are separated by approximately 100 meters. The short-lived positron-emitting radioisotopes are generated using the 10-MV tandem Van de Graaff accelerator located in the main TUNL building, which provides the capability of producing short-lived positron-emitting isotopes such as carbon-11 (11C: 20 minute half-life), nitrogen-13 (13N; 10 minute half-life), fluorine-18 (18F; 110 minute half-life), and oxygen-15 (15O; 2 minute half-life). The radioisotopes may

  6. Comparability of a short food frequency questionnaire to assess diet quality: the DISCOVER study.

    Science.gov (United States)

    Dehghan, Mahshid; Ge, Yipeng; El Sheikh, Wala; Bawor, Monica; Rangarajan, Sumathy; Dennis, Brittany; Vair, Judith; Sholer, Heather; Hutchinson, Nichole; Iordan, Elizabeth; Mackie, Pam; Samaan, Zainab

    2017-09-01

    This study aims to assess comparability of a short food frequency questionnaire (SFFQ) used in the Determinants of Suicide: Conventional and Emergent Risk Study (DISCOVER Study) with a validated comprehensive FFQ (CFFQ). A total of 127 individuals completed SFFQ and CFFQ. Healthy eating was measured using Healthy Eating Score (HES). Estimated food intake and healthy eating assessed by SFFQ was compared with the CFFQ. For most food groups and HES, the highest Spearman's rank correlation coefficients between the two FFQs were r > .60. For macro-nutrients, the correlations exceeded 0.4. Cross-classification of quantile analysis showed that participants were classified between 46% and 81% into the exact same quantiles, while 10% or less were misclassified into opposite quantiles. The Bland-Altman plots showed an acceptable level of agreement between the two dietary measurement methods. The SFFQ can be used for Canadian with psychiatric disorders to rank them based on their dietary intake.

  7. Observation of short period fluctuation of CygX-1 with balloon

    International Nuclear Information System (INIS)

    Nakagawa, Michio; Sakurai, Takahisa; Uchida, Masayoshi

    1977-01-01

    CygX-1 presents very complex short period fluctuation of X-ray, therefore the hard X-ray was especially observed in 1972 and 1973 with large balloons, and the data were analyzed. This short period fluctuation and energy spectra of CygX-1 in the normal and flare time bands were compared. The observing apparatuses consisted of the 3 in diameter NaI detector and a high pressure proportional counter. The observing method is to turn the gondora alternately to the directions of source (ON) and background (OFF). As for the data analysis, the events at ON and OFF in the observation data in 1972 and 1973 were plotted for time interval. The background component is in agreement with Poisson's distribution, but source component is not. This difference for Poisson's distribution means the behavior of CygX-1. The power spectrum was analyzed, and the strong power density was observed at 5.4 x 10 -2 Hz in ON, but such power density was not observed in OFF. Accordingly this is presumed to be caused by CygX-1. The events for time interval in flare time are shown. The rise of about 2.9 σ exists at 80 msec. The count rates were compared for photon energy in the normal and flare times. The short period fluctuation of hard X-ray from CygX-1 deviates from Poisson's distribution and is different in the normal and flare times. (Nakai, Y.)

  8. Vision-based online vibration estimation of the in-vessel inspection flexible robot with short-time Fourier transformation

    International Nuclear Information System (INIS)

    Wang, Hesheng; Chen, Weidong; Xu, Lifei; He, Tao

    2015-01-01

    Highlights: • Vision-based online vibration estimation method for a flexible arm is proposed. • The vibration signal is obtained by image processing in unknown environments. • Vibration parameters are estimated by short-time Fourier transformation. - Abstract: The vibration should be suppressed if it happens during the motion of a flexible robot or under the influence of external disturbance caused by its structural features and material properties, because the vibration may affect the positioning accuracy and image quality. In Tokamak environment, we need to get the real-time vibration information on vibration suppression of robotic arm, however, some sensors are not allowed in the extreme Tokamak environment. This paper proposed a vision-based method for online vibration estimation of a flexible manipulator, which is achieved by utilizing the environment image information from the end-effector camera to estimate its vibration. Short-time Fourier Transformation with adaptive window length method is used to estimate vibration parameters of non-stationary vibration signals. Experiments with one-link flexible manipulator equipped with camera are carried out to validate the feasibility of this method in this paper.

  9. Vision-based online vibration estimation of the in-vessel inspection flexible robot with short-time Fourier transformation

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hesheng [Key Laboratory of System Control and Information Processing, Ministry of Education of China (China); Department of Automation, Shanghai Jiao Tong University, Shanghai 200240 (China); Chen, Weidong, E-mail: wdchen@sjtu.edu.cn [Key Laboratory of System Control and Information Processing, Ministry of Education of China (China); Department of Automation, Shanghai Jiao Tong University, Shanghai 200240 (China); Xu, Lifei; He, Tao [Key Laboratory of System Control and Information Processing, Ministry of Education of China (China); Department of Automation, Shanghai Jiao Tong University, Shanghai 200240 (China)

    2015-10-15

    Highlights: • Vision-based online vibration estimation method for a flexible arm is proposed. • The vibration signal is obtained by image processing in unknown environments. • Vibration parameters are estimated by short-time Fourier transformation. - Abstract: The vibration should be suppressed if it happens during the motion of a flexible robot or under the influence of external disturbance caused by its structural features and material properties, because the vibration may affect the positioning accuracy and image quality. In Tokamak environment, we need to get the real-time vibration information on vibration suppression of robotic arm, however, some sensors are not allowed in the extreme Tokamak environment. This paper proposed a vision-based method for online vibration estimation of a flexible manipulator, which is achieved by utilizing the environment image information from the end-effector camera to estimate its vibration. Short-time Fourier Transformation with adaptive window length method is used to estimate vibration parameters of non-stationary vibration signals. Experiments with one-link flexible manipulator equipped with camera are carried out to validate the feasibility of this method in this paper.

  10. Three-factor models versus time series models: quantifying time-dependencies of interactions between stimuli in cell biology and psychobiology for short longitudinal data.

    Science.gov (United States)

    Frank, Till D; Kiyatkin, Anatoly; Cheong, Alex; Kholodenko, Boris N

    2017-06-01

    Signal integration determines cell fate on the cellular level, affects cognitive processes and affective responses on the behavioural level, and is likely to be involved in psychoneurobiological processes underlying mood disorders. Interactions between stimuli may subjected to time effects. Time-dependencies of interactions between stimuli typically lead to complex cell responses and complex responses on the behavioural level. We show that both three-factor models and time series models can be used to uncover such time-dependencies. However, we argue that for short longitudinal data the three factor modelling approach is more suitable. In order to illustrate both approaches, we re-analysed previously published short longitudinal data sets. We found that in human embryonic kidney 293 cells cells the interaction effect in the regulation of extracellular signal-regulated kinase (ERK) 1 signalling activation by insulin and epidermal growth factor is subjected to a time effect and dramatically decays at peak values of ERK activation. In contrast, we found that the interaction effect induced by hypoxia and tumour necrosis factor-alpha for the transcriptional activity of the human cyclo-oxygenase-2 promoter in HEK293 cells is time invariant at least in the first 12-h time window after stimulation. Furthermore, we applied the three-factor model to previously reported animal studies. In these studies, memory storage was found to be subjected to an interaction effect of the beta-adrenoceptor agonist clenbuterol and certain antagonists acting on the alpha-1-adrenoceptor / glucocorticoid-receptor system. Our model-based analysis suggests that only if the antagonist drug is administer in a critical time window, then the interaction effect is relevant. © The authors 2016. Published by Oxford University Press on behalf of the Institute of Mathematics and its Applications. All rights reserved.

  11. Mining biological information from 3D short time-series gene expression data: the OPTricluster algorithm.

    Science.gov (United States)

    Tchagang, Alain B; Phan, Sieu; Famili, Fazel; Shearer, Heather; Fobert, Pierre; Huang, Yi; Zou, Jitao; Huang, Daiqing; Cutler, Adrian; Liu, Ziying; Pan, Youlian

    2012-04-04

    Nowadays, it is possible to collect expression levels of a set of genes from a set of biological samples during a series of time points. Such data have three dimensions: gene-sample-time (GST). Thus they are called 3D microarray gene expression data. To take advantage of the 3D data collected, and to fully understand the biological knowledge hidden in the GST data, novel subspace clustering algorithms have to be developed to effectively address the biological problem in the corresponding space. We developed a subspace clustering algorithm called Order Preserving Triclustering (OPTricluster), for 3D short time-series data mining. OPTricluster is able to identify 3D clusters with coherent evolution from a given 3D dataset using a combinatorial approach on the sample dimension, and the order preserving (OP) concept on the time dimension. The fusion of the two methodologies allows one to study similarities and differences between samples in terms of their temporal expression profile. OPTricluster has been successfully applied to four case studies: immune response in mice infected by malaria (Plasmodium chabaudi), systemic acquired resistance in Arabidopsis thaliana, similarities and differences between inner and outer cotyledon in Brassica napus during seed development, and to Brassica napus whole seed development. These studies showed that OPTricluster is robust to noise and is able to detect the similarities and differences between biological samples. Our analysis showed that OPTricluster generally outperforms other well known clustering algorithms such as the TRICLUSTER, gTRICLUSTER and K-means; it is robust to noise and can effectively mine the biological knowledge hidden in the 3D short time-series gene expression data.

  12. Comparative endocrinological responses to short transportation of Equidae (Equus asinus and Equus caballus).

    Science.gov (United States)

    Fazio, Esterina; Medica, Pietro; Cravana, Cristina; Aveni, Francesca; Ferlazzo, Adriana

    2013-03-01

    In order to evaluate the effects of short transportation on β-endorphin, adrenocorticotropic hormone (ACTH) and cortisol changes, 12 healthy stallions of Equidae (Equus asinus and Equus caballus) were studied before and after transportation of 50 km. Blood samples were collected 1 week before transportation in basal conditions, immediately before loading and after transportation and unloading, on their arrival at the breeding station. Compared to basal and before values, donkeys showed an increase in circulating ACTH (P donkeys. Horses facing forward (direction of travel) showed higher (P donkeys; horses facing backward (the opposite direction of travel) showed lower (P donkeys and only of cortisol in horses, suggesting that transportation for donkeys may be more stressful than horses. © 2012 The Authors Animal Science Journal © 2012 Japanese Society of Animal Science.

  13. Short-time dynamics of random-bond Potts ferromagnet with continuous self-dual quenched disorders

    OpenAIRE

    Pan, Z. Q.; Ying, H. P.; Gu, D. W.

    2001-01-01

    We present Monte Carlo simulation results of random-bond Potts ferromagnet with the Olson-Young self-dual distribution of quenched disorders in two-dimensions. By exploring the short-time scaling dynamics, we find universal power-law critical behavior of the magnetization and Binder cumulant at the critical point, and thus obtain estimates of the dynamic exponent $z$ and magnetic exponent $\\eta$, as well as the exponent $\\theta$. Our special attention is paid to the dynamic process for the $q...

  14. The Central Engines of Short-Duration Gamma-Ray Bursts

    Science.gov (United States)

    Metzger, Brian; Arcones, A.; Quataert, E.; Martinez-Pinedo, G.

    2010-01-01

    One of the most important discoveries made with Swift is that long and short-duration gamma-ray bursts (GRBs) originate from distinct stellar progenitors. While long GRBs track ongoing star formation and result from the deaths of massive stars, short GRBs have been localized to both early and late-type galaxies, suggesting a more evolved progenitor population. Although the origin of short GRBs remains a mystery, the most popular and well-studied model is accretion following the merger of neutron star binaries. This model is qualitatively consistent with both the demographics of short GRBs and the lack of a bright associated supernova in some cases. Despite these successes, this picture has grown complex with the discovery that short GRBs are often followed by a "tail" of emission (usually soft X-rays) lasting 100 seconds after the burst. Such energetic, late-time emission from the central engine is difficult to explain in standard merger pictures. One proposed explanation is late-time "fall-back" onto the black hole of material that was ejected during the merger into highly eccentric, marginally-bound orbits. As this matter decompresses from nuclear densities, however, it undergoes rapid-neutron capture (r-process) nucleosynthesis, which can release energy comparable to the orbital binding energy. This implies that the r-process (normally thought unimportant dynamically in astrophysical contexts) has important implications for the quantity and time-dependence of fall-back and, ultimately, the source of flaring and identity of the central engine.

  15. Comparative Short-Term Clinical Outcomes of Mediastinum Tumor Excision Performed by Conventional VATS and Single-Port VATS

    OpenAIRE

    Wu, Ching-Feng; Gonzalez-Rivas, Diego; Wen, Chih-Tsung; Liu, Yun-Hen; Wu, Yi-Cheng; Chao, Yin-Kai; Hsieh, Ming-Ju; Wu, Ching-Yang; Chen, Wei-Hsun

    2015-01-01

    Abstract Single-port video-assisted thoracoscopic surgery (VATS) has been widely applied recently. However, there are still only few reports describing its use in mediastinum tumor resection. We present the technique of single-port video-assisted thoracoscopic mediastinum tumor resection and compare it with conventional VATS with regard to short-term outcome. We retrospectively enrolled 105 patients who received mediastinum surgery in Chang Gung Memorial Hospital. Sixteen patients received st...

  16. Correlation between Very Short and Short-Term Blood Pressure Variability in Diabetic-Hypertensive and Healthy Subjects.

    Science.gov (United States)

    Casali, Karina R; Schaan, Beatriz D; Montano, Nicola; Massierer, Daniela; M F Neto, Flávio; Teló, Gabriela H; Ledur, Priscila S; Reinheimer, Marilia; Sbruzzi, Graciele; Gus, Miguel

    2018-02-01

    Blood pressure (BP) variability can be evaluated by 24-hour ambulatory BP monitoring (24h-ABPM), but its concordance with results from finger BP measurement (FBPM) has not been established yet. The aim of this study was to compare parameters of short-term (24h-ABPM) with very short-term BP variability (FBPM) in healthy (C) and diabetic-hypertensive (DH) subjects. Cross-sectional study with 51 DH subjects and 12 C subjects who underwent 24h-ABPM [extracting time-rate, standard deviation (SD), coefficient of variation (CV)] and short-term beat-to-beat recording at rest and after standing-up maneuvers [FBPM, extracting BP and heart rate (HR) variability parameters in the frequency domain, autoregressive spectral analysis]. Spearman correlation coefficient was used to correlate BP and HR variability parameters obtained from both FBPM and 24h-ABPM (divided into daytime, nighttime, and total). Statistical significance was set at p ABPM) and LF component of short-term variability (FBPM, total, R = 0.591, p = 0.043); standard deviation (24h-ABPM) with LF component BPV (FBPM, total, R = 0.608, p = 0.036), coefficient of variation (24h-ABPM) with total BPV (FBPM, daytime, -0.585, p = 0.046) and alpha index (FBPM, daytime, -0.592, p = 0.043), time rate (24h-ABPM) and delta LF/HF (FBPM, total, R = 0.636, p = 0.026; daytime R = 0,857, p ABPM (total, daytime) reflect BP and HR variability evaluated by FBPM in healthy individuals. This does not apply for DH subjects.

  17. Short- and long-term effects of real-time medication monitoring with short message service (SMS) reminders for missed doses on the refill adherence of people with Type 2 diabetes: evidence from a randomised controlled trial.

    NARCIS (Netherlands)

    Vervloet, M.; Dijk, L. van; Bakker, D.H. de; Souverein, P.C.; Santen-Reestman, J.; Vlijmen, B. van; Aarle, M.C.W. van; Hoek, L.S. van der; Bouvy, M.L.

    2014-01-01

    Aims: To investigate short- and long-term effects of real-time monitoring medication use combined with short message service (SMS) reminders for missed doses on refill adherence to oral anti-diabetic medication. Methods: A randomized controlled trial with two intervention groups and one control

  18. Spectrogram analysis of selected tremor signals using short-time Fourier transform and continuous wavelet transform

    Directory of Open Access Journals (Sweden)

    D. Seidl

    1999-06-01

    Full Text Available Among a variety of spectrogram methods Short-Time Fourier Transform (STFT and Continuous Wavelet Transform (CWT were selected to analyse transients in non-stationary tremor signals. Depending on the properties of the tremor signal a more suitable representation of the signal is gained by CWT. Three selected broadband tremor signals from the volcanos Mt. Stromboli, Mt. Semeru and Mt. Pinatubo were analyzed using both methods. The CWT can also be used to extend the definition of coherency into a time-varying coherency spectrogram. An example is given using array data from the volcano Mt. Stromboli.

  19. On board short-time high temperature heat treatment of ballast water: a field trial under operational conditions.

    Science.gov (United States)

    Quilez-Badia, Gemma; McCollin, Tracy; Josefsen, Kjell D; Vourdachas, Anthony; Gill, Margaret E; Mesbahi, Ehsan; Frid, Chris L J

    2008-01-01

    A ballast water short-time high temperature heat treatment technique was applied on board a car-carrier during a voyage from Egypt to Belgium. Ballast water from three tanks was subjected for a few seconds to temperatures ranging from 55 degrees C to 80 degrees C. The water was heated using the vessel's heat exchanger steam and a second heat exchanger was used to pre-heat and cool down the water. The treatment was effective at causing mortality of bacteria, phytoplankton and zooplankton. The International Maritime Organization (IMO) standard was not agreed before this study was carried out, but comparing our results gives a broad indication that the IMO standard would have been met in some of the tests for the zooplankton, in all the tests for the phytoplankton; and probably on most occasions for the bacteria. Passing the water through the pump increased the kill rate but increasing the temperature above 55 degrees C did not improve the heat treatment's efficacy.

  20. Short-time effect of heavy metals upon microbial community activity

    International Nuclear Information System (INIS)

    Wang Fei; Yao Jun; Si Yang; Chen Huilun; Russel, Mohammad; Chen Ke; Qian Yiguang; Zaray, Gyula; Bramanti, Emilia

    2010-01-01

    Microcalorimetry was applied to assess and compare the toxic effect of heavy metals, such as As, Cu, Cd, Cr, Co, Pb and Zn, on the soil microbial activities and community. About 1.0 g soil spiked 5.0 mg glucose and 5.0 mg ammonium sulfate, the microbial activities were recorded as power-time curves, and their indices, microbial growth rate constant k, total heat evolution Q T , metabolic enthalpy ΔH met and mass specific heat rate J Q/S , were calculated. Comparing these thermodynamic parameters associated with growth yield, a general order of toxicity to the soil was found to be Cr > Pb > As > Co > Zn > Cd > Cu. When soil was exposed to heavy metals, the amount of bacteria and fungi decreased with the incubation time, and the bacterial number diminished sharply. It illustrates that fungi are more tolerant, and bacteria-fungi ratio would be altered under metal stress. To determine the status of the glucose consumed, a glucose biosensor with eggshell membrane was used to measure the remaining glucose in soil sample. Results showed that the time at which glucose was consumed completely was agreed with the microcalorimetric time to a large extent, and depended on the toxicity of heavy metals as well.

  1. Short-time effect of heavy metals upon microbial community activity.

    Science.gov (United States)

    Wang, Fei; Yao, Jun; Si, Yang; Chen, Huilun; Russel, Mohammad; Chen, Ke; Qian, Yiguang; Zaray, Gyula; Bramanti, Emilia

    2010-01-15

    Microcalorimetry was applied to assess and compare the toxic effect of heavy metals, such as As, Cu, Cd, Cr, Co, Pb and Zn, on the soil microbial activities and community. About 1.0 g soil spiked 5.0mg glucose and 5.0mg ammonium sulfate, the microbial activities were recorded as power-time curves, and their indices, microbial growth rate constant k, total heat evolution Q(T), metabolic enthalpy Delta H(met) and mass specific heat rate J(Q/S), were calculated. Comparing these thermodynamic parameters associated with growth yield, a general order of toxicity to the soil was found to be Cr>Pb>As>Co>Zn>Cd>Cu. When soil was exposed to heavy metals, the amount of bacteria and fungi decreased with the incubation time, and the bacterial number diminished sharply. It illustrates that fungi are more tolerant, and bacteria-fungi ratio would be altered under metal stress. To determine the status of the glucose consumed, a glucose biosensor with eggshell membrane was used to measure the remaining glucose in soil sample. Results showed that the time at which glucose was consumed completely was agreed with the microcalorimetric time to a large extent, and depended on the toxicity of heavy metals as well.

  2. Short-time effect of heavy metals upon microbial community activity

    Energy Technology Data Exchange (ETDEWEB)

    Wang Fei [Key Laboratory of Biogeology and Environmental Geology of Chinese Ministry of Education and Sino-Hungarian Joint Laboratory of Environmental Science and Health and School of Environmental Sciences, China University of Geosciences, 430074 Wuhan (China); Yao Jun, E-mail: yaojun@cug.edu.cn [Key Laboratory of Biogeology and Environmental Geology of Chinese Ministry of Education and Sino-Hungarian Joint Laboratory of Environmental Science and Health and School of Environmental Sciences, China University of Geosciences, 430074 Wuhan (China); Si Yang; Chen Huilun; Russel, Mohammad; Chen Ke; Qian Yiguang [Key Laboratory of Biogeology and Environmental Geology of Chinese Ministry of Education and Sino-Hungarian Joint Laboratory of Environmental Science and Health and School of Environmental Sciences, China University of Geosciences, 430074 Wuhan (China); Zaray, Gyula [Department of Chemical Technology and Environmental Chemistry, Eoetvoes University, H-1518 Budapest, P.O. Box 32 (Hungary); Bramanti, Emilia [Laboratory of Instrumental Analytical Chemistry, Institute for Chemical and Physical Processes, Area di Ricerca, Via G. Moruzzi 1, 56124 Pisa (Italy)

    2010-01-15

    Microcalorimetry was applied to assess and compare the toxic effect of heavy metals, such as As, Cu, Cd, Cr, Co, Pb and Zn, on the soil microbial activities and community. About 1.0 g soil spiked 5.0 mg glucose and 5.0 mg ammonium sulfate, the microbial activities were recorded as power-time curves, and their indices, microbial growth rate constant k, total heat evolution Q{sub T}, metabolic enthalpy {Delta}H{sub met} and mass specific heat rate J{sub Q/S}, were calculated. Comparing these thermodynamic parameters associated with growth yield, a general order of toxicity to the soil was found to be Cr > Pb > As > Co > Zn > Cd > Cu. When soil was exposed to heavy metals, the amount of bacteria and fungi decreased with the incubation time, and the bacterial number diminished sharply. It illustrates that fungi are more tolerant, and bacteria-fungi ratio would be altered under metal stress. To determine the status of the glucose consumed, a glucose biosensor with eggshell membrane was used to measure the remaining glucose in soil sample. Results showed that the time at which glucose was consumed completely was agreed with the microcalorimetric time to a large extent, and depended on the toxicity of heavy metals as well.

  3. Geometric patterns of time-delay plots from different cardiac rhythms and arrhythmias using short-term EKG signals.

    Science.gov (United States)

    Borracci, Raúl A; Montoya Pulvet, José D; Ingino, Carlos A; Fitz Maurice, Mario; Hirschon Prado, Alfredo; Dominé, Enrique

    2017-12-27

    To date, no systematic work has been intended to describe spatio-temporal patterns of cardiac rhythms using only short series of RR intervals, to facilitate visual or computerized-aided identification of EKG motifs for use in clinical practice. The aim of this study was to detect and classify eye-catching geometric patterns of Poincaré time-delay plots from different types of cardiac rhythms and arrhythmias using short-term EKG signals. Approximately 150-300 representative, consecutive beats were retrieved from 24-h Holter registers of 100 patients with different heart rhythms. Two-dimensional Poincaré charts were created, and the resulting geometric patterns were transformed into representative familiar eye-catching drawings to interpret different arrhythmias. Poincaré plot representation of RR interval data revealed a wide variety of visual patterns: (i) comet-shaped for sinus rhythm; (ii) torpedo-shaped for sinus bradycardia; (iii) cigarette-shaped for sinus tachycardia; (iv) butterfly-shaped for sinus tachycardia and isolated atrial premature complexes; (v) arrow-shaped for isolated premature complexes and inappropriate sinus tachycardia; (vi) inverted fan-shaped for sinus rhythm with frequent atrial premature complexes; (vii) tornado-shaped for atrial flutter and atrial tachycardia; and (viii) fan-shaped for atrial fibrillation. Modified Poincaré plots with smoothed lines connecting successive points could accurately classify different types of arrhythmias based on short RR interval sequence variability. Characteristic emergent patterns can be visually identified and eventually could be distinguished by an automatic classification system able to discern between arrhythmias. This work provides an alternative method to interpret time-delay plots obtained from short-term EKG signal recordings. © 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  4. Classification of brain tumours using short echo time 1H MR spectra

    Science.gov (United States)

    Devos, A.; Lukas, L.; Suykens, J. A. K.; Vanhamme, L.; Tate, A. R.; Howe, F. A.; Majós, C.; Moreno-Torres, A.; van der Graaf, M.; Arús, C.; Van Huffel, S.

    2004-09-01

    The purpose was to objectively compare the application of several techniques and the use of several input features for brain tumour classification using Magnetic Resonance Spectroscopy (MRS). Short echo time 1H MRS signals from patients with glioblastomas ( n = 87), meningiomas ( n = 57), metastases ( n = 39), and astrocytomas grade II ( n = 22) were provided by six centres in the European Union funded INTERPRET project. Linear discriminant analysis, least squares support vector machines (LS-SVM) with a linear kernel and LS-SVM with radial basis function kernel were applied and evaluated over 100 stratified random splittings of the dataset into training and test sets. The area under the receiver operating characteristic curve (AUC) was used to measure the performance of binary classifiers, while the percentage of correct classifications was used to evaluate the multiclass classifiers. The influence of several factors on the classification performance has been tested: L2- vs. water normalization, magnitude vs. real spectra and baseline correction. The effect of input feature reduction was also investigated by using only the selected frequency regions containing the most discriminatory information, and peak integrated values. Using L2-normalized complete spectra the automated binary classifiers reached a mean test AUC of more than 0.95, except for glioblastomas vs. metastases. Similar results were obtained for all classification techniques and input features except for water normalized spectra, where classification performance was lower. This indicates that data acquisition and processing can be simplified for classification purposes, excluding the need for separate water signal acquisition, baseline correction or phasing.

  5. Optimization of irradiation decay and counting times in nuclear activation analysis using short-lived nuclides

    International Nuclear Information System (INIS)

    Bjoernstad, T.

    This work describes a method and outlines a procedure for optim- ization of an activation analysis with respect to the experimental times, irradiation time, t(subi), decay time and counting time. The method is based on the 'minimum relative standard deviation criterion', and specially designed for the use on short-lived nuclides. A computer program, COMB1, is written in the BASIC language in order to make the calculations easier and faster. It is intended to be understandable, and easily applicable on a computer of modest size. Time and cost are important factors, especially for routine analysis on a service basis. In such cases one can often allow a controlled reduction in the analysis quality (through a higher relative standard deviation). The procedure outlined can therefore help find acceptable conditions by calculation of the 'best practical' (or reasonable) experimental time values, and the minimum number of accumulation cycles necessary to fulfil the requirements given. (Auth.)

  6. Breastfeeding, Infant Formula, and Introduction to Complementary Foods-Comparing Data Obtained by Questionnaires and Health Visitors' Reports to Weekly Short Message Service Text Messages.

    Science.gov (United States)

    Bruun, Signe; Buhl, Susanne; Husby, Steffen; Jacobsen, Lotte Neergaard; Michaelsen, Kim F; Sørensen, Jan; Zachariassen, Gitte

    2017-11-01

    Studies on prevalence and effects of breastfeeding call for reliable and precise data collection to optimize infant nutrition, growth, and health. Data on breastfeeding and infant nutrition are at risk of, for example, recall bias or social desirability bias. The aim of the present analysis was to compare data on infant nutrition, that is, breastfeeding, use of infant formula, and introduction to complementary foods, obtained by four different methods. We assumed that weekly short message service (SMS) questions were the most reliable method, to which the other methods were compared. The study population was part of the Odense Child Cohort. The four methods used were: (a) self-administered questionnaire 3 months postpartum, (b) self-administered questionnaire 18 months postpartum, (c) registrations from health visitors visiting the families several times within the first year of life, and (d) weekly SMS questions introduced shortly after birth. In total, 639 singleton mothers with data from all four methods were included. The proportion of mothers initiating breastfeeding varied from 86% to 97%, the mean duration of exclusive breastfeeding from 12 to 19 weeks, and the mean age when introduced to complementary foods from 19 to 21 weeks. The mean duration of any breastfeeding was 33 weeks across methods. Compared with the weekly SMS questions, the self-administered questionnaires and the health visitors' reports resulted in a greater proportion of mothers with an unknown breastfeeding status, a longer duration of exclusive breastfeeding and later introduction to complementary foods, while the duration of any breastfeeding did not differ.

  7. [A Paired Case Controlled Study Comparing the Short-term Outcomes of Da Vinci RATS and VATS Approach for Non-small Cell Lung Cancer].

    Science.gov (United States)

    Dai, Feng; Xu, Shiguang; Xu, Wei; Ding, Renquan; Liu, Bo; Meng, Hao; Kang, Yunteng; Meng, Xiangrui; Lin, Jie; Wang, Shumin

    2018-03-20

    Da Vinci Surgical System is one of the greatest inventions of the 20th century, which represents the development direction of the precise minimally invasive surgical techniques, the aim of this study was to comparing the short-term outcomes between da Vinci robot-assisted lobectomy and video-assisted thoracic surgery (VATS) lobectomy for non-small cell lung cancer. 45 pairs of non-small cell lung cancer patients underwent pulmonary lobectomy with da Vinci Robotic assisted thoracoscopic (RATS) and VATS approach during the same period from January 2014 to January 2017. The operative time, estimated blood loss (EBL), total number and total groups of dissected lymph nodes, postoperative duration of drainage, the first day volume of drainage, total volume of drainage were compared. No perioperative death and convertion to thoracotomy occured in both groups. There were significant difference between RATS group and VATS group in EBL [(50.30±32.33) mL vs (208.60±132.63) mL], the first day volume of drainage [(275.00±145.42) mL vs (347.60±125.80) mL], the dissected total number [(22.67±9.67) vs (15.51±5.41)] and total team [(6.31±1.43) vs (4.91±1.04)] of lymph node. There were no significant difference in other outcomes. RATS is safe and effective and took better short-outcomes than VATS in non-small cell lung cancer.

  8. Transmodal comparison of auditory, motor, and visual post-processing with and without intentional short-term memory maintenance.

    Science.gov (United States)

    Bender, Stephan; Behringer, Stephanie; Freitag, Christine M; Resch, Franz; Weisbrod, Matthias

    2010-12-01

    To elucidate the contributions of modality-dependent post-processing in auditory, motor and visual cortical areas to short-term memory. We compared late negative waves (N700) during the post-processing of single lateralized stimuli which were separated by long intertrial intervals across the auditory, motor and visual modalities. Tasks either required or competed with attention to post-processing of preceding events, i.e. active short-term memory maintenance. N700 indicated that cortical post-processing exceeded short movements as well as short auditory or visual stimuli for over half a second without intentional short-term memory maintenance. Modality-specific topographies pointed towards sensory (respectively motor) generators with comparable time-courses across the different modalities. Lateralization and amplitude of auditory/motor/visual N700 were enhanced by active short-term memory maintenance compared to attention to current perceptions or passive stimulation. The memory-related N700 increase followed the characteristic time-course and modality-specific topography of the N700 without intentional memory-maintenance. Memory-maintenance-related lateralized negative potentials may be related to a less lateralised modality-dependent post-processing N700 component which occurs also without intentional memory maintenance (automatic memory trace or effortless attraction of attention). Encoding to short-term memory may involve controlled attention to modality-dependent post-processing. Similar short-term memory processes may exist in the auditory, motor and visual systems. Copyright © 2010 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  9. Effect of low-temperature long-time and high-temperature short-time blanching and frying treatments on the French fry quality of six Irish potato cultivars

    OpenAIRE

    Ngobese, Nomali Ziphorah; Workneh, Tilahun Seyoum; Siwela, Muthulisi

    2017-01-01

    Processing conditions are an important determinant of French fry quality. However, the effect of low-temperature long-time (LTLT) and high-temperature short-time (HTST) blanching and frying treatments has not been investigated in many cultivars. The current study investigates the effect of the sequential application of these treatments on French fries processed from six Irish potato cultivars (Fianna, Innovator, Mondial, Navigator, Panamera and Savanna). Blanching was effected at 75 °C for 10...

  10. Relationship of Corneal Pain Sensitivity With Dry Eye Symptoms in Dry Eye With Short Tear Break-Up Time.

    Science.gov (United States)

    Kaido, Minako; Kawashima, Motoko; Ishida, Reiko; Tsubota, Kazuo

    2016-03-01

    The purpose of this prospective comparative study was to investigate corneal sensitivity in subjects with unstable tear film, with and without dry eye (DE) symptoms. Forty-one eyes of 41 volunteers (mean age: 45.1 ± 9.4 years; age range, 23-57 years), with normal tear function and ocular surface except for tear stability, were studied. The eyes were divided into two groups depending on the presence or absence of DE symptoms: 21 eyes with DE symptoms (symptomatic group); and 20 eyes without DE symptoms (asymptomatic group). Three types of corneal sensitivity values were measured using a Cochet-Bonnet esthesiometer: the sensitivity for perception of touch (S-touch), the sensitivity for blinking (S-blink), and the sensitivity for pain (S-pain). Mean S-blink and S-pain were significantly higher in the symptomatic group than in the asymptomatic group (P 0.05). Corneal sensitivity for blinking and pain evoked by increased stimuli was higher in the symptomatic group (subjects with short break-up time DE) compared with subjects who have no DE symptoms despite decreased tear stability. The presence of both tear instability and hyperesthesia, rather than tear instability alone, may contribute to DE pathogenesis.

  11. First Isochronous Time-of-Flight Mass Measurements of Short-Lived Projectile Fragments in the ESR

    International Nuclear Information System (INIS)

    Stadlmann, J.; Geissel, H.; Hausmann, M.; Nolden, F.; Radon, T.; Schatz, H.; Scheidenberger, C.; Attallah, F.; Beckert, K.; Bosch, F.; Falch, M.; Franczak, B.; Franzke, B.; Kerscher, Th.; Klepper, O.; Kluge, H.J.; Kozhuharov, C.; Loebner, K.E.G.; Muenzenberg, G.; Novikov, Yu.N.; Steck, M.; Sun, Z.; Suemmerer, K.; Weick, H.; Wollnik, H.

    2000-01-01

    A new method for precise mass measurements of short-lived hot nuclei is presented. These nuclei were produced via projectile fragmentation, separated with the FRS and injected into the storage ring ESR being operated in the isochronous mode. The revolution time of the ions is measured with a time-of-flight detector sensitive to single particles. This new method allows access to exotic nuclei with half-lives in the microsecond region. First results from this novel method obtained with measurements on neutron-deficient fragments of a chromium primary beam with half-lives down to 50 ms are reported. A precision of deltam/m ≤ 5 · 10 -6 has been achieved

  12. Probabilistic eruption forecasting at short and long time scales

    Science.gov (United States)

    Marzocchi, Warner; Bebbington, Mark S.

    2012-10-01

    Any effective volcanic risk mitigation strategy requires a scientific assessment of the future evolution of a volcanic system and its eruptive behavior. Some consider the onus should be on volcanologists to provide simple but emphatic deterministic forecasts. This traditional way of thinking, however, does not deal with the implications of inherent uncertainties, both aleatoric and epistemic, that are inevitably present in observations, monitoring data, and interpretation of any natural system. In contrast to deterministic predictions, probabilistic eruption forecasting attempts to quantify these inherent uncertainties utilizing all available information to the extent that it can be relied upon and is informative. As with many other natural hazards, probabilistic eruption forecasting is becoming established as the primary scientific basis for planning rational risk mitigation actions: at short-term (hours to weeks or months), it allows decision-makers to prioritize actions in a crisis; and at long-term (years to decades), it is the basic component for land use and emergency planning. Probabilistic eruption forecasting consists of estimating the probability of an eruption event and where it sits in a complex multidimensional time-space-magnitude framework. In this review, we discuss the key developments and features of models that have been used to address the problem.

  13. [Short-term memory characteristics of vibration intensity tactile perception on human wrist].

    Science.gov (United States)

    Hao, Fei; Chen, Li-Juan; Lu, Wei; Song, Ai-Guo

    2014-12-25

    In this study, a recall experiment and a recognition experiment were designed to assess the human wrist's short-term memory characteristics of tactile perception on vibration intensity, by using a novel homemade vibrotactile display device based on the spatiotemporal combination vibration of multiple micro vibration motors as a test device. Based on the obtained experimental data, the short-term memory span, recognition accuracy and reaction time of vibration intensity were analyzed. From the experimental results, some important conclusions can be made: (1) The average short-term memory span of tactile perception on vibration intensity is 3 ± 1 items; (2) The greater difference between two adjacent discrete intensities of vibrotactile stimulation is defined, the better average short-term memory span human wrist gets; (3) There is an obvious difference of the average short-term memory span on vibration intensity between the male and female; (4) The mechanism of information extraction in short-term memory of vibrotactile display is to traverse the scanning process by comparison; (5) The recognition accuracy and reaction time performance of vibrotactile display compares unfavourably with that of visual and auditory. The results from this study are important for designing vibrotactile display coding scheme.

  14. A comparison of computerized adaptive testing and fixed-length short forms for the Prosthetic Limb Users Survey of Mobility (PLUS-MTM).

    Science.gov (United States)

    Amtmann, Dagmar; Bamer, Alyssa M; Kim, Jiseon; Bocell, Fraser; Chung, Hyewon; Park, Ryoungsun; Salem, Rana; Hafner, Brian J

    2017-09-01

    New health status instruments can be administered by computerized adaptive test or short forms. The Prosthetic Limb Users Survey of Mobility (PLUS-M TM ) is a self-report measure of mobility for prosthesis users with lower limb loss. This study used the PLUS-M to examine advantages and disadvantages of computerized adaptive test and short forms. To compare scores obtained from computerized adaptive test to scores obtained from fixed-length short forms (7-item and 12-item) in order to provide guidance to researchers and clinicians on how to select the best form of administration for different uses. Cross-sectional, observational study. Individuals with lower limb loss completed the PLUS-M by computerized adaptive test and short forms. Administration time, correlations between the scores, and standard errors were compared. Scores and standard errors from the computerized adaptive test, 7-item short form, and 12-item short form were highly correlated and all forms of administration were efficient. Computerized adaptive test required less time to administer than either paper or electronic short forms; however, time savings were minimal compared to the 7-item short form. Results indicate that the PLUS-M computerized adaptive test is most efficient, and differences in scores between administration methods are minimal. The main advantage of the computerized adaptive test was more reliable scores at higher levels of mobility compared to short forms. Clinical relevance Health-related item banks, like the Prosthetic Limb Users Survey of Mobility (PLUS-M TM ), can be administered by computerized adaptive testing (CAT) or as fixed-length short forms (SFs). Results of this study will help clinicians and researchers decide whether they should invest in a CAT administration system or whether SFs are more appropriate.

  15. Objective and Comprehensive Evaluation of Bisulfite Short Read Mapping Tools

    Directory of Open Access Journals (Sweden)

    Hong Tran

    2014-01-01

    Full Text Available Background. Large-scale bisulfite treatment and short reads sequencing technology allow comprehensive estimation of methylation states of Cs in the genomes of different tissues, cell types, and developmental stages. Accurate characterization of DNA methylation is essential for understanding genotype phenotype association, gene and environment interaction, diseases, and cancer. Aligning bisulfite short reads to a reference genome has been a challenging task. We compared five bisulfite short read mapping tools, BSMAP, Bismark, BS-Seeker, BiSS, and BRAT-BW, representing two classes of mapping algorithms (hash table and suffix/prefix tries. We examined their mapping efficiency (i.e., the percentage of reads that can be mapped to the genomes, usability, running time, and effects of changing default parameter settings using both real and simulated reads. We also investigated how preprocessing data might affect mapping efficiency. Conclusion. Among the five programs compared, in terms of mapping efficiency, Bismark performs the best on the real data, followed by BiSS, BSMAP, and finally BRAT-BW and BS-Seeker with very similar performance. If CPU time is not a constraint, Bismark is a good choice of program for mapping bisulfite treated short reads. Data quality impacts a great deal mapping efficiency. Although increasing the number of mismatches allowed can increase mapping efficiency, it not only significantly slows down the program, but also runs the risk of having increased false positives. Therefore, users should carefully set the related parameters depending on the quality of their sequencing data.

  16. Short Term Prediction of PM10 Concentrations Using Seasonal Time Series Analysis

    Directory of Open Access Journals (Sweden)

    Hamid Hazrul Abdul

    2016-01-01

    Full Text Available Air pollution modelling is one of an important tool that usually used to make short term and long term prediction. Since air pollution gives a big impact especially to human health, prediction of air pollutants concentration is needed to help the local authorities to give an early warning to people who are in risk of acute and chronic health effects from air pollution. Finding the best time series model would allow prediction to be made accurately. This research was carried out to find the best time series model to predict the PM10 concentrations in Nilai, Negeri Sembilan, Malaysia. By considering two seasons which is wet season (north east monsoon and dry season (south west monsoon, seasonal autoregressive integrated moving average model were used to find the most suitable model to predict the PM10 concentrations in Nilai, Negeri Sembilan by using three error measures. Based on AIC statistics, results show that ARIMA (1, 1, 1 × (1, 0, 012 is the most suitable model to predict PM10 concentrations in Nilai, Negeri Sembilan.

  17. Vehicle emissions of short-lived and long-lived climate forcers: trends and tradeoffs.

    Science.gov (United States)

    Edwards, Morgan R; Klemun, Magdalena M; Kim, Hyung Chul; Wallington, Timothy J; Winkler, Sandra L; Tamor, Michael A; Trancik, Jessika E

    2017-08-24

    Evaluating technology options to mitigate the climate impacts of road transportation can be challenging, particularly when they involve a tradeoff between long-lived emissions (e.g., carbon dioxide) and short-lived emissions (e.g., methane or black carbon). Here we present trends in short- and long-lived emissions for light- and heavy-duty transport globally and in the U.S., EU, and China over the period 2000-2030, and we discuss past and future changes to vehicle technologies to reduce these emissions. We model the tradeoffs between short- and long-lived emission reductions across a range of technology options, life cycle emission intensities, and equivalency metrics. While short-lived vehicle emissions have decreased globally over the past two decades, significant reductions in CO 2 will be required by mid-century to meet climate change mitigation targets. This is true regardless of the time horizon used to compare long- and short-lived emissions. The short-lived emission intensities of some low-CO 2 technologies are higher than others, and thus their suitability for meeting climate targets depends sensitively on the evaluation time horizon. Other technologies offer low intensities of both short-lived emissions and CO 2 .

  18. Travel Time to Hospital for Childbirth: Comparing Calculated Versus Reported Travel Times in France.

    Science.gov (United States)

    Pilkington, Hugo; Prunet, Caroline; Blondel, Béatrice; Charreire, Hélène; Combier, Evelyne; Le Vaillant, Marc; Amat-Roze, Jeanne-Marie; Zeitlin, Jennifer

    2018-01-01

    Objectives Timely access to health care is critical in obstetrics. Yet obtaining reliable estimates of travel times to hospital for childbirth poses methodological challenges. We compared two measures of travel time, self-reported and calculated, to assess concordance and to identify determinants of long travel time to hospital for childbirth. Methods Data came from the 2010 French National Perinatal Survey, a national representative sample of births (N = 14 681). We compared both travel time measures by maternal, maternity unit and geographic characteristics in rural, peri-urban and urban areas. Logistic regression models were used to study factors associated with reported and calculated times ≥30 min. Cohen's kappa coefficients were also calculated to estimate the agreement between reported and calculated times according to women's characteristics. Results In urban areas, the proportion of women with travel times ≥30 min was higher when reported rather than calculated times were used (11.0 vs. 3.6%). Longer reported times were associated with non-French nationality [adjusted odds ratio (aOR) 1.3 (95% CI 1.0-1.7)] and inadequate prenatal care [aOR 1.5 (95% CI 1.2-2.0)], but not for calculated times. Concordance between the two measures was higher in peri-urban and rural areas (52.4 vs. 52.3% for rural areas). Delivery in a specialised level 2 or 3 maternity unit was a principal determinant of long reported and measured times in peri-urban and rural areas. Conclusions for Practice The level of agreement between reported and calculated times varies according to geographic context. Poor measurement of travel time in urban areas may mask problems in accessibility.

  19. Short-time dynamics of lysozyme solutions with competing short-range attraction and long-range repulsion: Experiment and theory

    Science.gov (United States)

    Riest, Jonas; Nägele, Gerhard; Liu, Yun; Wagner, Norman J.; Godfrin, P. Douglas

    2018-02-01

    Recently, atypical static features of microstructural ordering in low-salinity lysozyme protein solutions have been extensively explored experimentally and explained theoretically based on a short-range attractive plus long-range repulsive (SALR) interaction potential. However, the protein dynamics and the relationship to the atypical SALR structure remain to be demonstrated. Here, the applicability of semi-analytic theoretical methods predicting diffusion properties and viscosity in isotropic particle suspensions to low-salinity lysozyme protein solutions is tested. Using the interaction potential parameters previously obtained from static structure factor measurements, our results of Monte Carlo simulations representing seven experimental lysoyzme samples indicate that they exist either in dispersed fluid or random percolated states. The self-consistent Zerah-Hansen scheme is used to describe the static structure factor, S(q), which is the input to our calculation schemes for the short-time hydrodynamic function, H(q), and the zero-frequency viscosity η. The schemes account for hydrodynamic interactions included on an approximate level. Theoretical predictions for H(q) as a function of the wavenumber q quantitatively agree with experimental results at small protein concentrations obtained using neutron spin echo measurements. At higher concentrations, qualitative agreement is preserved although the calculated hydrodynamic functions are overestimated. We attribute the differences for higher concentrations and lower temperatures to translational-rotational diffusion coupling induced by the shape and interaction anisotropy of particles and clusters, patchiness of the lysozyme particle surfaces, and the intra-cluster dynamics, features not included in our simple globular particle model. The theoretical results for the solution viscosity, η, are in qualitative agreement with our experimental data even at higher concentrations. We demonstrate that semi

  20. A Statistical and Spectral Model for Representing Noisy Sounds with Short-Time Sinusoids

    Directory of Open Access Journals (Sweden)

    Myriam Desainte-Catherine

    2005-07-01

    Full Text Available We propose an original model for noise analysis, transformation, and synthesis: the CNSS model. Noisy sounds are represented with short-time sinusoids whose frequencies and phases are random variables. This spectral and statistical model represents information about the spectral density of frequencies. This perceptually relevant property is modeled by three mathematical parameters that define the distribution of the frequencies. This model also represents the spectral envelope. The mathematical parameters are defined and the analysis algorithms to extract these parameters from sounds are introduced. Then algorithms for generating sounds from the parameters of the model are presented. Applications of this model include tools for composers, psychoacoustic experiments, and pedagogy.

  1. Rotor-System Log-Decrement Identification Using Short-Time Fourier-Transform Filter

    Directory of Open Access Journals (Sweden)

    Qihang Li

    2015-01-01

    Full Text Available With the increase of the centrifugal compressor capability, such as large scale LNG and CO2 reinjection, the stability margin evaluation is crucial to assure the compressor work in the designed operating conditions in field. Improving the precision of parameter identification of stability is essential and necessary as well. Based on the time-varying characteristics of response vibration during the sine-swept process, a short-time Fourier transform (STFT filter was introduced to increase the signal-noise ratio and improve the accuracy of the estimated stability parameters. A finite element model was established to simulate the sine-swept process, and the simulated vibration signals were used to study the filtering effect and demonstrate the feasibility to identify the stability parameters by using Multiple-Input and Multiple-Output system identification method that combines the prediction error method and instrumental variable method. Simulation results show that the identification method with STFT filter improves the estimated accuracy much well and makes the curves of frequency response function clearer. Experiment was carried out on a test rig as well, which indicates the identification method is feasible in stability identification, and the results of experiment indicate that STFT filter works very well.

  2. On the Option Effects of Short-Time Work Arrangements

    NARCIS (Netherlands)

    Huisman, Kuno; Thijssen, J.J.J.

    2018-01-01

    We analyse the short term work (STW) regulations that several OECD countries introduced after the 2007 financial crisis. We view these measures as a collection of real options and study the dynamic effect of STW on the endogenous liquidation decision of the firm. While STW delays a firm’s

  3. 25 CFR 26.30 - Does the Job Training Program provide part-time training or short-term training?

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Does the Job Training Program provide part-time training or short-term training? 26.30 Section 26.30 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Training Services § 26.30 Does the Job Training...

  4. High-Temperature Short-Time Pasteurization System for Donor Milk in a Human Milk Bank Setting

    OpenAIRE

    Diana Escuder-Vieco; Irene Espinosa-Martos; Juan M. Rodríguez; Nieves Corzo; Antonia Montilla; Pablo Siegfried; Carmen R. Pallás-Alonso; Carmen R. Pallás-Alonso; Leónides Fernández

    2018-01-01

    Donor milk is the best alternative for the feeding of preterm newborns when mother's own milk is unavailable. For safety reasons, it is usually pasteurized by the Holder method (62.5°C for 30 min). Holder pasteurization results in a microbiological safe product but impairs the activity of many biologically active compounds such as immunoglobulins, enzymes, cytokines, growth factors, hormones or oxidative stress markers. High-temperature short-time (HTST) pasteurization has been proposed as an...

  5. Comparing and contrasting therapeutic effects of cognitive-behavior therapy for older adults suffering from insomnia with short and long objective sleep duration.

    Science.gov (United States)

    Lovato, Nicole; Lack, Leon; Kennaway, David J

    2016-06-01

    This study evaluated the efficacy of a brief group-based program of cognitive-behavior therapy for insomnia (CBTi) for older adults suffering from chronic insomnia with short objective sleep relative to those with long sleep duration. Ninety-one adults (male = 43, mean age = 63.34, standard deviation (SD) = 6.41) with sleep maintenance insomnia were selected from a community-based sample. The participants were classified as short sleepers (SS; treatment program of CBTi (N = 30 SS; N = 33 LS) or to a wait-list control condition (N = 9 SS, N = 19 LS). One-week sleep diaries, actigraphy, and a comprehensive battery of questionnaires were used to evaluate the efficacy of CBTi for those with short objective sleep relative to those with long sleep duration. Outcome measures were taken at pretreatment, posttreatment, and a 3-month follow-up. CBTi produced robust and durable improvements in quality of sleep, including reduced wake after sleep onset and improved sleep efficiency. Participants reported a reduction of scores on the Insomnia Severity Index, Flinders Fatigue Scale, Epworth Sleepiness Scale, Daytime Feeling and Functioning Scale, Sleep Anticipatory Anxiety Questionnaire, the Dysfunctional Beliefs and Attitudes about Sleep Scale, and gains on the Sleep Self-Efficacy Scale. All improvements were significant relative to their respective SS or LS wait-list group. The benefits of CBTi were comparable with those who had short and long objective sleep before the treatment. Older adults suffering from chronic insomnia with short objective sleep received comparable therapeutic benefits following CBTi relative to those with long objective sleep duration. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Pricing decision model for new and remanufactured short-life cycle products with time-dependent demand

    Directory of Open Access Journals (Sweden)

    Shu San Gan

    2015-12-01

    Full Text Available In this study we develop a model that optimizes the price for new and remanufactured short life-cycle products where demands are time-dependent and price sensitive. While there has been very few published works that attempt to model remanufacturing decisions for products with short life cycle, we believe that there are many situations where remanufacturing short life cycle products is rewarding economically as well as environmentally. The system that we model consists of a retailer, a manufacturer, and a collector of used product from the end customers. Two different scenarios are evaluated for the system. The first is the independent situation where each party attempts to maximize his/her own total profit and the second is the joint profit model where we optimize the combined total profit for all three members of the supply chain. Manufacturer acts as the Stackelberg leader in the independently optimized scenario, while in the other the intermediate prices are determined by coordinated pricing policy. The results suggest that (i reducing the price of new products during the decline phase does not give better profit for the whole system, (ii the total profit obtained from optimizing each player is lower than the total profit of the integrated model, and (iii speed of change in demand influences the robustness of the prices as well as the total profit gained.

  7. Three-dimensional ultrashort echo time MRI and Short T2 images generated from subtraction for determination of tumor burden in lung cancer: Preclinical investigation in transgenic mice.

    Science.gov (United States)

    Müller, Andreas; Jagoda, Philippe; Fries, Peter; Gräber, Stefan; Bals, Robert; Buecker, Arno; Jungnickel, Christopher; Beisswenger, Christoph

    2018-02-01

    To investigate the potential of 3D ultrashort echo time MRI and short T 2 images generated by subtraction for determination of total tumor burden in lung cancer. As an animal model of spontaneously developing non-small cell lung cancer, the K-rasLA1 transgenic mouse was used. Three-dimensional MR imaging was performed with radial k-space acquisition and echo times of 20 µs and 1 ms. For investigation of the short T 2 component in the recorded signal, subtraction images were generated from these data sets and used for consensus identification of tumors. Next, manual segmentation was performed on all MR images by two independent investigators. MRI data were compared with the results from histologic investigations and among the investigators. Tumor number and total tumor burden from imaging experiments correlated strongly with the results of histologic investigations. Intra- and interuser comparison showed highest correlations between the individual measurements for ultra-short TE MRI. Three-dimensional MRI protocols facilitate accurate tumor identification in mice harboring lung tumors. Ultrashort TE MRI is the superior imaging strategy when investigating lung tumors of miscellaneous size with 3D MR imaging strategies. Magn Reson Med 79:1052-1060, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  8. Highly efficient indoor air purification using adsorption-enhanced-photocatalysis-based microporous TiO2 at short residence time.

    Science.gov (United States)

    Lv, Jinze; Zhu, Lizhong

    2013-01-01

    A short residence time is a key design parameter for the removal of organic pollutants in catalyst-based indoor air purification systems. In this study, we synthesized a series of TiO2 with different micropore volumes and studied their removal efficiency of indoor carbonyl pollutants at a short residence time. Our results indicated that the superior adsorption capability of TiO2 with micropores improved its performance in the photocatalytic degradation of cyclohexanone, while the photocatalytic removal of the pollutant successfully kept porous TiO2 from becoming saturated. When treated with 1 mg m(-3) cyclohexanone at a relatively humidity of 18%, the adsorption amount on microporous TiO2 was 5.4-7.9 times higher than that on P25. Removal efficiency via photocatalysis followed'the same order as the adsorption amount: TiO2-5 > TiO2-20 > TiO2-60 > TiO2-180 > P25. The advantage of microporous TiO2 over P25 became more pronounced when the residence time declined from 0.072 to 0.036 s. Moreover, as the concentration of cyclohexanone deceased from 1000 ppb to 500 ppb, removal efficiency by microporous TiO2 increased more rapidly than P25.

  9. Double peak-induced distance error in short-time-Fourier-transform-Brillouin optical time domain reflectometers event detection and the recovery method.

    Science.gov (United States)

    Yu, Yifei; Luo, Linqing; Li, Bo; Guo, Linfeng; Yan, Jize; Soga, Kenichi

    2015-10-01

    The measured distance error caused by double peaks in the BOTDRs (Brillouin optical time domain reflectometers) system is a kind of Brillouin scattering spectrum (BSS) deformation, discussed and simulated for the first time in the paper, to the best of the authors' knowledge. Double peak, as a kind of Brillouin spectrum deformation, is important in the enhancement of spatial resolution, measurement accuracy, and crack detection. Due to the variances of the peak powers of the BSS along the fiber, the measured starting point of a step-shape frequency transition region is shifted and results in distance errors. Zero-padded short-time-Fourier-transform (STFT) can restore the transition-induced double peaks in the asymmetric and deformed BSS, thus offering more accurate and quicker measurements than the conventional Lorentz-fitting method. The recovering method based on the double-peak detection and corresponding BSS deformation can be applied to calculate the real starting point, which can improve the distance accuracy of the STFT-based BOTDR system.

  10. The effect of a novel low temperature-short time (LTST) process to extend the shelf-life of fluid milk.

    Science.gov (United States)

    Myer, Phillip R; Parker, Kyle R; Kanach, Andrew T; Zhu, Tengliang; Morgan, Mark T; Applegate, Bruce M

    2016-01-01

    Pasteurization has long been the standard method to extend the shelf-life of dairy products, as well as a means to reduce microbial load and the risk of food-borne pathogens. However, the process has limitations, which include cost effectiveness, high energy input, and reduction of product quality/organoleptic characteristics. In an effort to reduce these limitations and extend shelf-life, this study examined a novel low temperature, short time (LTST) method in which dispersed milk in the form of droplets was treated with low heat/pressure variation over a short treatment time, in conjunction with pasteurization. Lactobacillus fermentum and Pseudomonas fluorescens Migula were exposed to conventional pasteurization treatments with and without LTST. Using these organisms, the LTST addition was able to reduce microbial load below detection limits; 1.0 × 10(1) cfu/mL, from approximately 1.2 × 10(8) and 1.0 × 10(7) cfu/mL for L. fermentum and P. fluorescens Migula, respectively. In addition, the shelf-life of the treated, raw, and uninoculated product was prolonged from 14 to 35 days, compared with standard pasteurization, to as long as 63 days with the LTST amendment. Sensory analysis of samples also demonstrated equal or greater preference for LTST + pasteurization treated milk when compared to pasteurization alone (α = 0.05). Conventional pasteurization was effective at reducing the above mentioned microorganisms by as much as 5.0 log10 cfu/mL. However, LTST was able to achieve 7.0-8.0 log10 cfu/mL reduction of the same microorganisms. In addition, BActerial Rapid Detection using Optical scattering Technology detected and identified microorganisms isolated both pre- and post-treatment, of which the only organisms surviving LTST were Bacillus spp. Increased lethality, improved shelf-life, and equal or better organoleptic characteristics without increased energy consumption demonstrate the effectiveness of the incorporation of LTST. The improved

  11. High-Temperature Short-Time Pasteurization System for Donor Milk in a Human Milk Bank Setting

    Directory of Open Access Journals (Sweden)

    Diana Escuder-Vieco

    2018-05-01

    Full Text Available Donor milk is the best alternative for the feeding of preterm newborns when mother's own milk is unavailable. For safety reasons, it is usually pasteurized by the Holder method (62.5°C for 30 min. Holder pasteurization results in a microbiological safe product but impairs the activity of many biologically active compounds such as immunoglobulins, enzymes, cytokines, growth factors, hormones or oxidative stress markers. High-temperature short-time (HTST pasteurization has been proposed as an alternative for a better preservation of some of the biological components of human milk although, at present, there is no equipment available to perform this treatment under the current conditions of a human milk bank. In this work, the specific needs of a human milk bank setting were considered to design an HTST equipment for the continuous and adaptable (time-temperature combination processing of donor milk. Microbiological quality, activity of indicator enzymes and indices for thermal damage of milk were evaluated before and after HTST treatment of 14 batches of donor milk using different temperature and time combinations and compared to the results obtained after Holder pasteurization. The HTST system has accurate and simple operation, allows the pasteurization of variable amounts of donor milk and reduces processing time and labor force. HTST processing at 72°C for, at least, 10 s efficiently destroyed all vegetative forms of microorganisms present initially in raw donor milk although sporulated Bacillus sp. survived this treatment. Alkaline phosphatase was completely destroyed after HTST processing at 72 and 75°C, but γ-glutamil transpeptidase showed higher thermoresistance. Furosine concentrations in HTST-treated donor milk were lower than after Holder pasteurization and lactulose content for HTST-treated donor milk was below the detection limit of analytical method (10 mg/L. In conclusion, processing of donor milk at 72°C for at least 10 s in

  12. High-Temperature Short-Time Pasteurization System for Donor Milk in a Human Milk Bank Setting.

    Science.gov (United States)

    Escuder-Vieco, Diana; Espinosa-Martos, Irene; Rodríguez, Juan M; Corzo, Nieves; Montilla, Antonia; Siegfried, Pablo; Pallás-Alonso, Carmen R; Fernández, Leónides

    2018-01-01

    Donor milk is the best alternative for the feeding of preterm newborns when mother's own milk is unavailable. For safety reasons, it is usually pasteurized by the Holder method (62.5°C for 30 min). Holder pasteurization results in a microbiological safe product but impairs the activity of many biologically active compounds such as immunoglobulins, enzymes, cytokines, growth factors, hormones or oxidative stress markers. High-temperature short-time (HTST) pasteurization has been proposed as an alternative for a better preservation of some of the biological components of human milk although, at present, there is no equipment available to perform this treatment under the current conditions of a human milk bank. In this work, the specific needs of a human milk bank setting were considered to design an HTST equipment for the continuous and adaptable (time-temperature combination) processing of donor milk. Microbiological quality, activity of indicator enzymes and indices for thermal damage of milk were evaluated before and after HTST treatment of 14 batches of donor milk using different temperature and time combinations and compared to the results obtained after Holder pasteurization. The HTST system has accurate and simple operation, allows the pasteurization of variable amounts of donor milk and reduces processing time and labor force. HTST processing at 72°C for, at least, 10 s efficiently destroyed all vegetative forms of microorganisms present initially in raw donor milk although sporulated Bacillus sp. survived this treatment. Alkaline phosphatase was completely destroyed after HTST processing at 72 and 75°C, but γ-glutamil transpeptidase showed higher thermoresistance. Furosine concentrations in HTST-treated donor milk were lower than after Holder pasteurization and lactulose content for HTST-treated donor milk was below the detection limit of analytical method (10 mg/L). In conclusion, processing of donor milk at 72°C for at least 10 s in this HTST system

  13. High-Temperature Short-Time Pasteurization System for Donor Milk in a Human Milk Bank Setting

    Science.gov (United States)

    Escuder-Vieco, Diana; Espinosa-Martos, Irene; Rodríguez, Juan M.; Corzo, Nieves; Montilla, Antonia; Siegfried, Pablo; Pallás-Alonso, Carmen R.; Fernández, Leónides

    2018-01-01

    Donor milk is the best alternative for the feeding of preterm newborns when mother's own milk is unavailable. For safety reasons, it is usually pasteurized by the Holder method (62.5°C for 30 min). Holder pasteurization results in a microbiological safe product but impairs the activity of many biologically active compounds such as immunoglobulins, enzymes, cytokines, growth factors, hormones or oxidative stress markers. High-temperature short-time (HTST) pasteurization has been proposed as an alternative for a better preservation of some of the biological components of human milk although, at present, there is no equipment available to perform this treatment under the current conditions of a human milk bank. In this work, the specific needs of a human milk bank setting were considered to design an HTST equipment for the continuous and adaptable (time-temperature combination) processing of donor milk. Microbiological quality, activity of indicator enzymes and indices for thermal damage of milk were evaluated before and after HTST treatment of 14 batches of donor milk using different temperature and time combinations and compared to the results obtained after Holder pasteurization. The HTST system has accurate and simple operation, allows the pasteurization of variable amounts of donor milk and reduces processing time and labor force. HTST processing at 72°C for, at least, 10 s efficiently destroyed all vegetative forms of microorganisms present initially in raw donor milk although sporulated Bacillus sp. survived this treatment. Alkaline phosphatase was completely destroyed after HTST processing at 72 and 75°C, but γ-glutamil transpeptidase showed higher thermoresistance. Furosine concentrations in HTST-treated donor milk were lower than after Holder pasteurization and lactulose content for HTST-treated donor milk was below the detection limit of analytical method (10 mg/L). In conclusion, processing of donor milk at 72°C for at least 10 s in this HTST system

  14. Road Short-Term Travel Time Prediction Method Based on Flow Spatial Distribution and the Relations

    Directory of Open Access Journals (Sweden)

    Mingjun Deng

    2016-01-01

    Full Text Available There are many short-term road travel time forecasting studies based on time series, but indeed, road travel time not only relies on the historical travel time series, but also depends on the road and its adjacent sections history flow. However, few studies have considered that. This paper is based on the correlation of flow spatial distribution and the road travel time series, applying nearest neighbor and nonparametric regression method to build a forecasting model. In aspect of spatial nearest neighbor search, three different space distances are defined. In addition, two forecasting functions are introduced: one combines the forecasting value by mean weight and the other uses the reciprocal of nearest neighbors distance as combined weight. Three different distances are applied in nearest neighbor search, which apply to the two forecasting functions. For travel time series, the nearest neighbor and nonparametric regression are applied too. Then minimizing forecast error variance is utilized as an objective to establish the combination model. The empirical results show that the combination model can improve the forecast performance obviously. Besides, the experimental results of the evaluation for the computational complexity show that the proposed method can satisfy the real-time requirement.

  15. SHORT DISSIPATION TIMES OF PROTO-PLANETARY DISKS: AN ARTIFACT OF SELECTION EFFECTS?

    International Nuclear Information System (INIS)

    Pfalzner, Susanne; Steinhausen, Manuel; Menten, Karl

    2014-01-01

    The frequency of disks around young stars, a key parameter for understanding planet formation, is most readily determined in young stellar clusters where many relatively coeval stars are located in close proximity. Observational studies seem to show that the disk frequency decreases rapidly with cluster age with <10% of cluster stars retaining their disks for longer than 2-6 Myr. Given that at least half of all stars in the field seem to harbor one or more planets, this would imply extremely fast disk dispersal and rapid planet growth. Here we question the validity of this constraint by demonstrating that the short disk dissipation times inferred to date might have been heavily underestimated by selection effects. Critically, for ages >3 Myr only stars that originally populated the densest areas of very populous clusters, which are prone to disk erosion, are actually considered. This tiny sample may not be representative of the majority of stars. In fact, the higher disk fractions in co-moving groups indicate that it is likely that over 30% of all field stars retain their disks well beyond 10 Myr, leaving ample time for planet growth. Equally, our solar system, with a likely formation time >10 Myr, need no longer be an exception but in fact typical of planetary systems

  16. Construction of a flash-photolysis apparatus having a short discharge time

    International Nuclear Information System (INIS)

    Devillers, C.

    1964-01-01

    Flash photolysis aims at reaching directly the primary mechanisms resulting from the action of light on an absorbent matter. This makes it necessary to produce a flash as short and as bright as possible. Our main effort was directed towards reducing the duration of the flash by decreasing the self-inductance of the discharge circuit. A description of this circuit and study of the characteristics of the apparatus are followed by a short description of the two analytical methods: flash spectrography and absorption spectrophotometry at a given wave-length. (author) [fr

  17. Short communication

    African Journals Online (AJOL)

    abp

    2017-09-04

    Sep 4, 2017 ... Face-to-face interviews were conducted using a standardized ... Short communication. Open Access ... clinic during the time of the study and were invited to participate in the study. .... consume them. This is another ...

  18. EXPLORING THE POTENTIAL OF SHORT-TIME FOURIER TRANSFORMS FOR ANALYZING SKIN CONDUCTANCE AND PUPILLOMETRY IN REAL-TIME APPLICATIONS

    International Nuclear Information System (INIS)

    Roger Lew; Brian P. Dyre; Steffen Werner; Jeffrey C. Joe; Brian Wotring; Tuan Tran

    2008-01-01

    The development of real-time predictors of mental workload is critical for the practical application of augmented cognition to human-machine systems. This paper explores a novel method based on a short-time Fourier transform (STFT) for analyzing galvanic skin conductance (SC) and pupillometry time-series data to extract estimates of mental workload with temporal bandwidth high-enough to be useful for augmented cognition applications. We tested the method in the context of a process control task based on the DURESS simulation developed by Vincente and Pawlak (1994; ported to Java by Cosentino, and Ross, 1999). SC, pupil dilation, blink rate, and visual scanning patterns were measured for four participants actively engaged in controlling the simulation. Fault events were introduced that required participants to diagnose errors and make control adjustments to keep the simulator operating within a target range. We were interested in whether the STFT of these measures would produce visible effects of the increase in mental workload and stress associated with these events. Graphical exploratory data analysis of the STFT showed visible increases in the power spectrum across a range of frequencies directly following fault events. We believe this approach shows potential as a relatively unobtrusive, low-cost, high bandwidth measure of mental workload that could be particularly useful for the application of augmented cognition to human-machine systems

  19. EXPLORING THE POTENTIAL OF SHORT-TIME FOURIER TRANSFORMS FOR ANALYZING SKIN CONDUCTANCE AND PUPILLOMETRY IN REAL-TIME APPLICATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Roger Lew; Brian P. Dyre; Steffen Werner; Jeffrey C. Joe; Brian Wotring; Tuan Tran

    2008-09-01

    The development of real-time predictors of mental workload is critical for the practical application of augmented cognition to human-machine systems. This paper explores a novel method based on a short-time Fourier transform (STFT) for analyzing galvanic skin conductance (SC) and pupillometry time-series data to extract estimates of mental workload with temporal bandwidth high-enough to be useful for augmented cognition applications. We tested the method in the context of a process control task based on the DURESS simulation developed by Vincente and Pawlak (1994; ported to Java by Cosentino,& Ross, 1999). SC, pupil dilation, blink rate, and visual scanning patterns were measured for four participants actively engaged in controlling the simulation. Fault events were introduced that required participants to diagnose errors and make control adjustments to keep the simulator operating within a target range. We were interested in whether the STFT of these measures would produce visible effects of the increase in mental workload and stress associated with these events. Graphical exploratory data analysis of the STFT showed visible increases in the power spectrum across a range of frequencies directly following fault events. We believe this approach shows potential as a relatively unobtrusive, low-cost, high bandwidth measure of mental workload that could be particularly useful for the application of augmented cognition to human-machine systems.

  20. Sleep extension normalizes ERP of waking auditory sensory gating in healthy habitually short sleeping individuals.

    Science.gov (United States)

    Gumenyuk, Valentina; Korzyukov, Oleg; Roth, Thomas; Bowyer, Susan M; Drake, Christopher L

    2013-01-01

    Chronic sleep loss has been associated with increased daytime sleepiness, as well as impairments in memory and attentional processes. In the present study, we evaluated the neuronal changes of a pre-attentive process of wake auditory sensory gating, measured by brain event-related potential (ERP)--P50 in eight normal sleepers (NS) (habitual total sleep time (TST) 7 h 32 m) vs. eight chronic short sleeping individuals (SS) (habitual TST ≤6 h). To evaluate the effect of sleep extension on sensory gating, the extended sleep condition was performed in chronic short sleeping individuals. Thus, one week of time in bed (6 h 11 m) corresponding to habitual short sleep (hSS), and one week of extended time (∼ 8 h 25 m) in bed corresponding to extended sleep (eSS), were counterbalanced in the SS group. The gating ERP assessment was performed on the last day after each sleep condition week (normal sleep and habitual short and extended sleep), and was separated by one week with habitual total sleep time and monitored by a sleep diary. We found that amplitude of gating was lower in SS group compared to that in NS group (0.3 µV vs. 1.2 µV, at Cz electrode respectively). The results of the group × laterality interaction showed that the reduction of gating amplitude in the SS group was due to lower amplitude over the left hemisphere and central-midline sites relative to that in the NS group. After sleep extension the amplitude of gating increased in chronic short sleeping individuals relative to their habitual short sleep condition. The sleep condition × frontality interaction analysis confirmed that sleep extension significantly increased the amplitude of gating over frontal and central brain areas compared to parietal brain areas.

  1. Sleep extension normalizes ERP of waking auditory sensory gating in healthy habitually short sleeping individuals.

    Directory of Open Access Journals (Sweden)

    Valentina Gumenyuk

    Full Text Available Chronic sleep loss has been associated with increased daytime sleepiness, as well as impairments in memory and attentional processes. In the present study, we evaluated the neuronal changes of a pre-attentive process of wake auditory sensory gating, measured by brain event-related potential (ERP--P50 in eight normal sleepers (NS (habitual total sleep time (TST 7 h 32 m vs. eight chronic short sleeping individuals (SS (habitual TST ≤6 h. To evaluate the effect of sleep extension on sensory gating, the extended sleep condition was performed in chronic short sleeping individuals. Thus, one week of time in bed (6 h 11 m corresponding to habitual short sleep (hSS, and one week of extended time (∼ 8 h 25 m in bed corresponding to extended sleep (eSS, were counterbalanced in the SS group. The gating ERP assessment was performed on the last day after each sleep condition week (normal sleep and habitual short and extended sleep, and was separated by one week with habitual total sleep time and monitored by a sleep diary. We found that amplitude of gating was lower in SS group compared to that in NS group (0.3 µV vs. 1.2 µV, at Cz electrode respectively. The results of the group × laterality interaction showed that the reduction of gating amplitude in the SS group was due to lower amplitude over the left hemisphere and central-midline sites relative to that in the NS group. After sleep extension the amplitude of gating increased in chronic short sleeping individuals relative to their habitual short sleep condition. The sleep condition × frontality interaction analysis confirmed that sleep extension significantly increased the amplitude of gating over frontal and central brain areas compared to parietal brain areas.

  2. A probabilistic method for the estimation of ocean surface currents from short time series of HF radar data

    Science.gov (United States)

    Guérin, Charles-Antoine; Grilli, Stéphan T.

    2018-01-01

    We present a new method for inverting ocean surface currents from beam-forming HF radar data. In contrast with the classical method, which inverts radial currents based on shifts of the main Bragg line in the radar Doppler spectrum, the method works in the temporal domain and inverts currents from the amplitude modulation of the I and Q radar time series. Based on this principle, we propose a Maximum Likelihood approach, which can be combined with a Bayesian inference method assuming a prior current distribution, to infer values of the radial surface currents. We assess the method performance by using synthetic radar signal as well as field data, and systematically comparing results with those of the Doppler method. The new method is found advantageous for its robustness to noise at long range, its ability to accommodate shorter time series, and the possibility to use a priori information to improve the estimates. Limitations are related to current sign errors at far-ranges and biased estimates for small current values and very short samples. We apply the new technique to a data set from a typical 13.5 MHz WERA radar, acquired off of Vancouver Island, BC, and show that it can potentially improve standard synoptic current mapping.

  3. Flavor and flavor chemistry differences among milks processed by high-temperature, short-time pasteurization or ultra-pasteurization.

    Science.gov (United States)

    Jo, Y; Benoist, D M; Barbano, D M; Drake, M A

    2018-05-01

    Typical high-temperature, short-time (HTST) pasteurization encompasses a lower heat treatment and shorter refrigerated shelf life compared with ultra-pasteurization (UP) achieved by direct steam injection (DSI-UP) or indirect heat (IND-UP). A greater understanding of the effect of different heat treatments on flavor and flavor chemistry of milk is required to characterize, understand, and identify the sources of flavors. The objective of this study was to determine the differences in the flavor and volatile compound profiles of milk subjected to HTST, DSI-UP, or IND-UP using sensory and instrumental techniques. Raw skim and raw standardized 2% fat milks (50 L each) were processed in triplicate and pasteurized at 78°C for 15 s (HTST) or 140°C for 2.3 s by DSI-UP or IND-UP. Milks were cooled and stored at 4°C, then analyzed at d 0, 3, 7, and 14. Sensory attributes were determined using a trained panel, and aroma active compounds were evaluated by solid-phase micro-extraction or stir bar sorptive extraction followed by gas chromatography-mass spectrometry, gas chromatography-olfactometry, and gas chromatography-triple quad mass spectrometry. The UP milks had distinct cooked and sulfur flavors compared with HTST milks. The HTST milks had less diversity in aroma active compounds compared with UP milks. Flavor intensity of all milks decreased by d 14 of storage. Aroma active compound profiles were affected by heat treatment and storage time in both skim and 2% milk. High-impact aroma active compounds were hydrogen sulfide, dimethyl trisulfide, and methional in DSI-UP and 2 and 3-methylbutanal, furfural, 2-heptanone, 2-acetyl-1-pyrroline, 2-aminoacetophenone, benzaldehyde, and dimethyl sulfide in IND-UP. These results provide a foundation knowledge of the effect of heat treatments on flavor development and differences in sensory quality of UP milks. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  4. Femtosecond timing-jitter between photo-cathode laser and ultra-short electron bunches by means of hybrid compression

    CERN Document Server

    Pompili, Riccardo; Bellaveglia, M; Biagioni, A; Castorina, G; Chiadroni, E; Cianchi, A; Croia, M; Di Giovenale, D; Ferrario, M; Filippi, F; Gallo, A; Gatti, G; Giorgianni, F; Giribono, A; Li, W; Lupi, S; Mostacci, A; Petrarca, M; Piersanti, L; Di Pirro, G; Romeo, S; Scifo, J; Shpakov, V; Vaccarezza, C; Villa, F

    2017-01-01

    The generation of ultra-short electron bunches with ultra-low timing-jitter relative to the photo-cathode (PC) laser has been experimentally proved for the first time at the SPARC_LAB test-facility (INFN-LNF, Frascati) exploiting a two-stage hybrid compression scheme. The first stage employs RF-based compression (velocity-bunching), which shortens the bunch and imprints an energy chirp on it. The second stage is performed in a non-isochronous dogleg line, where the compression is completed resulting in a final bunch duration below 90 fs (rms). At the same time, the beam arrival timing-jitter with respect to the PC laser has been measured to be lower than 20 fs (rms). The reported results have been validated with numerical simulations.

  5. Femtosecond timing-jitter between photo-cathode laser and ultra-short electron bunches by means of hybrid compression

    International Nuclear Information System (INIS)

    Pompili, R; Anania, M P; Bellaveglia, M; Biagioni, A; Castorina, G; Chiadroni, E; Croia, M; Giovenale, D Di; Ferrario, M; Gallo, A; Gatti, G; Cianchi, A; Filippi, F; Giorgianni, F; Giribono, A; Lupi, S; Mostacci, A; Petrarca, M; Piersanti, L; Li, W

    2016-01-01

    The generation of ultra-short electron bunches with ultra-low timing-jitter relative to the photo-cathode (PC) laser has been experimentally proved for the first time at the SPARC-LAB test-facility (INFN-LNF, Frascati) exploiting a two-stage hybrid compression scheme. The first stage employs RF-based compression (velocity-bunching), which shortens the bunch and imprints an energy chirp on it. The second stage is performed in a non-isochronous dogleg line, where the compression is completed resulting in a final bunch duration below 90 fs (rms). At the same time, the beam arrival timing-jitter with respect to the PC laser has been measured to be lower than 20 fs (rms). The reported results have been validated with numerical simulations. (paper)

  6. Dead-time corrections on long-interval measurements of short-lived activities

    International Nuclear Information System (INIS)

    Irfan, M.

    1977-01-01

    A method has been proposed to make correction for counting losses due to dead time where the counting interval is comparable to or larger than the half-life of the activity under investigation. Counts due to background and any long-lived activity present in the source have been taken into consideration. The method is, under certain circumstances, capable of providing a valuable check on the accuracy of the dead time of the counting system. (Auth.)

  7. Time domain numerical calculations of the short electron bunch wakefields in resistive structures

    Energy Technology Data Exchange (ETDEWEB)

    Tsakanian, Andranik

    2010-10-15

    The acceleration of electron bunches with very small longitudinal and transverse phase space volume is one of the most actual challenges for the future International Linear Collider and high brightness X-Ray Free Electron Lasers. The exact knowledge on the wake fields generated by the ultra-short electron bunches during its interaction with surrounding structures is a very important issue to prevent the beam quality degradation and to optimize the facility performance. The high accuracy time domain numerical calculations play the decisive role in correct evaluation of the wake fields in advanced accelerators. The thesis is devoted to the development of a new longitudinally dispersion-free 3D hybrid numerical scheme in time domain for wake field calculation of ultra short bunches in structures with walls of finite conductivity. The basic approaches used in the thesis to solve the problem are the following. For materials with high but finite conductivity the model of the plane wave reflection from a conducting half-space is used. It is shown that in the conductive half-space the field components perpendicular to the interface can be neglected. The electric tangential component on the surface contributes to the tangential magnetic field in the lossless area just before the boundary layer. For high conducting media, the task is reduced to 1D electromagnetic problem in metal and the so-called 1D conducting line model can be applied instead of a full 3D space description. Further, a TE/TM (''transverse electric - transverse magnetic'') splitting implicit numerical scheme along with 1D conducting line model is applied to develop a new longitudinally dispersion-free hybrid numerical scheme in the time domain. The stability of the new hybrid numerical scheme in vacuum, conductor and bound cell is studied. The convergence of the new scheme is analyzed by comparison with the well-known analytical solutions. The wakefield calculations for a number of

  8. Development of a versatile high-temperature short-time (HTST) pasteurization device for small-scale processing of cell culture medium formulations.

    Science.gov (United States)

    Floris, Patrick; Curtin, Sean; Kaisermayer, Christian; Lindeberg, Anna; Bones, Jonathan

    2018-07-01

    The compatibility of CHO cell culture medium formulations with all stages of the bioprocess must be evaluated through small-scale studies prior to scale-up for commercial manufacturing operations. Here, we describe the development of a bespoke small-scale device for assessing the compatibility of culture media with a widely implemented upstream viral clearance strategy, high-temperature short-time (HTST) treatment. The thermal stability of undefined medium formulations supplemented with soy hydrolysates was evaluated upon variations in critical HTST processing parameters, namely, holding times and temperatures. Prolonged holding times of 43 s at temperatures of 110 °C did not adversely impact medium quality while significant degradation was observed upon treatment at elevated temperatures (200 °C) for shorter time periods (11 s). The performance of the device was benchmarked against a commercially available mini-pilot HTST system upon treatment of identical formulations on both platforms. Processed medium samples were analyzed by untargeted LC-MS/MS for compositional profiling followed by chemometric evaluation, which confirmed the observed degradation effects caused by elevated holding temperatures but revealed comparable performance of our developed device with the commercial mini-pilot setup. The developed device can assist medium optimization activities by reducing volume requirements relative to commercially available mini-pilot instrumentation and by facilitating fast throughput evaluation of heat-induced effects on multiple medium lots.

  9. Laparoscopic and open subtotal colectomies have similar short-term results.

    Science.gov (United States)

    Hoogenboom, Froukje J; Bosker, Robbert J I; Groen, Henk; Meijerink, Wilhelmus J H J; Lamme, Bas; Pierie, Jean Pierre E N

    2013-01-01

    Laparoscopic subtotal colectomy (STC) is a complex procedure. It is possible that short-term benefits for segmental resections cannot be attributed to this complex procedure. This study aims to assess differences in short-term results for laparoscopic versus open STC during a 15-year single-institute experience. We reviewed consecutive patients undergoing laparoscopic or open elective or subacute STC from January 1997 to December 2012. Fifty-six laparoscopic and 50 open STCs were performed. The operation time was significantly longer in the laparoscopic group, median 266 min (range 121-420 min), compared to 153 min (range 90-408 min) in the open group (p < 0.001). Median hospital stay showed no statistical difference, 14 days (range 1-129 days) in the laparoscopic and 13 days (range 1-85 days) in the open group. Between-group postoperative complications were not statistically different. Laparoscopic STC has short-term results similar to the open procedure, except for a longer operation time. The laparoscopic approach for STC is therefore only advisable in selected patients combined with extensive preoperative counseling. Copyright © 2013 S. Karger AG, Basel.

  10. Long-term clinical parameters after switching to nocturnal haemodialysis : a Dutch propensity-score-matched cohort study comparing patients on nocturnal haemodialysis with patients on three-times-a-week haemodialysis/haemodiafiltration

    NARCIS (Netherlands)

    Jansz, Thijs Thomas; Özyilmaz, Akin; Grooteman, Muriel P C; Hoekstra, Tiny; Romijn, Marieke; Blankestijn, Peter J; Bots, Michael L; van Jaarsveld, Brigit C

    2018-01-01

    OBJECTIVES: Nocturnal haemodialysis (NHD), characterised by 8-hour sessions ≥3 times a week, is known to improve clinical parameters in the short term compared with conventional-schedule haemodialysis (HD), generally 3×3.5-4 hours a week. We studied long-term effects of NHD and used patients on

  11. Microbial inactivation of paprika by a high-temperature short-X time treatment. Influence on color properties.

    Science.gov (United States)

    Almela, Luis; Nieto-Sandoval, José M; Fernández López, José A

    2002-03-13

    High-temperature short-time (HTST) treatments have been used to destroy the bioburden of paprika. With this in mind, we have designed a device to treat samples of paprika with a gas whose temperature, pressure, and composition can be selected. Temperatures and treatment times ranged from 130 to 170 degrees C and 4 to 6 s, respectively. The survival of the most commonly found microorganisms in paprika and any alteration in extractable and superficial color were examined. Data showed that the optimum HTST conditions were 145 degrees C, 1.5 kg/cm2 of overpressure, 6 s operation time, and a thermal fluid of saturated steam. No microbial growth was detected during storage after thermal treatment. To minimize the color losses, treated (HTST) paprika samples should be kept under refrigeration.

  12. Readiness for change and short-term outcomes of female adolescents in residential treatment for anorexia nervosa.

    Science.gov (United States)

    McHugh, Matthew D

    2007-11-01

    To determine if readiness for change (RFC) at admission predicted length of stay (LOS) and short-term outcomes among female adolescents in residential treatment for anorexia nervosa (AN). Using a prospective cohort design to collect data from participants (N = 65) at admission and discharge, Kaplan-Meier survival analysis and Cox regression tested whether RFC on admission predicted time in LOS to a favorable short-term outcome--a composite endpoint based on minimum criteria for weight gain, drive for thinness, depression, anxiety, and health-related quality of life (HRQOL). Participants with low RFC had a mean survival time to a favorable short-term outcome of 59.4 days compared to 34.1 days for those with high RFC (log rank = 8.44, df = 1, p = .003). The probability of a favorable short-term outcome was 5.30 times greater for participants with high RFC. Readiness for change is a useful predictor of a favorable short-term outcome and should be considered in the assessment profile of patients with AN. (c) 2007 by Wiley Periodicals, Inc.

  13. Effects of Repeated Testing on Short- and Long-Term Memory Performance across Different Test Formats

    Science.gov (United States)

    Stenlund, Tova; Sundström, Anna; Jonsson, Bert

    2016-01-01

    This study examined whether practice testing with short-answer (SA) items benefits learning over time compared to practice testing with multiple-choice (MC) items, and rereading the material. More specifically, the aim was to test the hypotheses of "retrieval effort" and "transfer appropriate processing" by comparing retention…

  14. The use of short-echo-time 1H MRS for childhood cerebellar tumours prior to histopathological diagnosis

    International Nuclear Information System (INIS)

    Harris, Lisa M.; Peet, Andrew C.; Davies, Nigel; Natarajan, Kal; MacPherson, Lesley; Foster, Katharine; Lateef, Shaheen; Sgouros, Spyridon; Brundler, Marie-Anne; Arvanitis, Theodoros N.; Grundy, Richard G.

    2007-01-01

    Proton magnetic resonance spectroscopy (MRS) measures concentrations of metabolites in vivo and provides a powerful method for identifying tumours. MRS has not entered routine clinical use partly due to the difficulty of analysing the spectra. To create a straightforward method for interpreting short-echo-time MRS of childhood cerebellar tumours. Single-voxel MRS (1.5-T Siemens Symphony NUM4, TR/TE 1,500/30 ms) was performed at presentation in 30 children with cerebellar tumours. The MRS results were analysed for comparison with histological diagnosis. Peak heights for N-acetyl aspartate (NAA), creatine (Cr), choline (Cho) and myo-inositol (mIns) were determined and receiver operator characteristic curves used to select ratios that best discriminated between the tumour types. The method was implemented by a group of clinicians and scientists, blinded to the results. A total of 27 MRS studies met the quality control criteria. NAA/Cr >4.0 distinguished all but one of the astrocytomas from the other tumours. A combination of Cr/Cho <0.75 and mIns/NAA <2.1 separated all the medulloblastomas from the ependymomas. Peak height ratios from short-echo-time MRS can accurately predict the histopathology of childhood cerebellar tumours. (orig.)

  15. X-ray short-time lags in the Fe-K energy band produced by scattering clouds in active galactic nuclei

    Science.gov (United States)

    Mizumoto, Misaki; Done, Chris; Hagino, Kouichi; Ebisawa, Ken; Tsujimoto, Masahiro; Odaka, Hirokazu

    2018-05-01

    X-rays illuminating the accretion disc in active galactic nuclei give rise to an iron K line and its associated reflection spectrum which are lagged behind the continuum variability by the light-travel time from the source to the disc. The measured lag timescales in the iron band can be as short as ˜Rg/c, where Rg is the gravitational radius, which is often interpreted as evidence for a very small continuum source close to the event horizon of a rapidly spinning black hole. However, the short lags can also be produced by reflection from more distant material, because the primary photons with no time-delay dilute the time-lags caused by the reprocessed photons. We perform a Monte-Carlo simulation to calculate the dilution effect in the X-ray reverberation lags from a half-shell of neutral material placed at 100 Rg from the central source. This gives lags of ˜2 Rg/c, but the iron line is a distinctly narrow feature in the lag-energy plot, whereas the data often show a broader line. We show that both the short lag and the line broadening can be reproduced if the scattering material is outflowing at ˜0.1c. The velocity structure in the wind can also give shifts in the line profile in the lag-energy plot calculated at different frequencies. Hence we propose that the observed broad iron reverberation lags and shifts in profile as a function of frequency of variability can arise from a disc wind at fairly large distances from the X-ray source.

  16. Design of short Italian sentences to assess near vision performance.

    Science.gov (United States)

    Calossi, Antonio; Boccardo, Laura; Fossetti, Alessandro; Radner, Wolfgang

    2014-01-01

    To develop and validate 28 short Italian sentences for the construction of the Italian version of the Radner Reading Chart to simultaneously measure near visual acuity and reading speed. 41 sentences were constructed in Italian language, following the procedure defined by Radner, to obtain "sentence optotypes" with comparable structure and with the same lexical and grammatical difficulty. Sentences were statistically selected and used in 211 normal, non-presbyopic, native Italian-speaking persons. The most equally matched sentences in terms of reading speed and number of reading errors were selected. To assess the validity of the reading speed results obtained with the 28 selected short sentences, we compared the reading speed and reading errors with the average obtained by reading two long 4th-grade paragraphs (97 and 90 words) under the same conditions. The overall mean reading speed of the tested persons was 189±26wpm. The 28 sentences more similar in terms of reading times were selected, achieving a coefficient of variation (the relative SD) of 2.2%. The reliability analyses yielded an overall Cronbach's alpha coefficient of 0.98. The correlation between the short sentences and the long paragraph was high (r=0.85, P<0.0001). The 28 short single Italian sentences optotypes were highly comparable in syntactical structure, number, position, and length of words, lexical difficulty, and reading length. The resulting Italian Radner Reading Chart is precise (high consistency) and practical (short sentences) and therefore useful for research and clinical practice to simultaneously measure near reading acuity and reading speed. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  17. Effects of a Short Drilling Implant Protocol on Osteotomy Site Temperature and Drill Torque.

    Science.gov (United States)

    Mihali, Sorin G; Canjau, Silvana; Cernescu, Anghel; Bortun, Cristina M; Wang, Hom-Lay; Bratu, Emanuel

    2018-02-01

    To establish a protocol for reducing the drilling sequence during implant site preparation based on temperature and insertion torque. The traditional conventional drilling sequence (used several drills with 0.6-mm increment each time) was compared with the proposed short drilling protocol (only used 2 drills: initial and final drill). One hundred drilling osteotomies were performed in bovine and porcine bones. Sets of 2 osteotomy sites were created in 5 bone densities using 2 types of drilling protocols. Thermographic pictures were captured throughout all drilling procedures and analyzed using ThermaCAM Researcher Professional 2.10. Torque values were determined during drilling by measuring electrical input and drill speed. There were statistically significant differences in bone temperature between the conventional and short drilling protocols during implant site preparation (analysis of variance P = 0.0008). However, there were no significant differences between the 2 types of drilling protocols for both implant diameters. Implant site preparation time was significantly reduced when using the short drilling protocol compared with the conventional drilling protocol (P drilling protocol proposed herein may represent a safe approach for implant site preparation.

  18. Antimicrobial and antiviral effect of high-temperature short-time (HTST) pasteurization applied to human milk.

    Science.gov (United States)

    Terpstra, Fokke G; Rechtman, David J; Lee, Martin L; Hoeij, Klaske Van; Berg, Hijlkeline; Van Engelenberg, Frank A C; Van't Wout, Angelica B

    2007-03-01

    In the United States, concerns over the transmission of infectious diseases have led to donor human milk generally being subjected to pasteurization prior to distribution and use. The standard method used by North American milk banks is Holder pasteurization (63 degrees C for 30 minutes). The authors undertook an experiment to validate the effects of a high-temperature short-time (HTST) pasteurization process (72 degrees C for 16 seconds) on the bioburden of human milk. It was concluded that HTST is effective in the elimination of bacteria as well as of certain important pathogenic viruses.

  19. The effect of chorionicity and twin-to-twin delivery time interval on short-term outcome of the second twin

    DEFF Research Database (Denmark)

    Hjortø, Sofie; Nickelsen, Carsten; Petersen, Janne

    2013-01-01

    Abstract Objectives: To investigate the effect of chorionicity and twin-to-twin delivery time interval on short-term outcome in the second twin. Additionally, to investigate predictors of adverse outcome in both twins. Methods: Data included vaginally delivered twins (≥ 36 weeks) from Copenhagen ...

  20. Motor Fault Diagnosis Based on Short-time Fourier Transform and Convolutional Neural Network

    Science.gov (United States)

    Wang, Li-Hua; Zhao, Xiao-Ping; Wu, Jia-Xin; Xie, Yang-Yang; Zhang, Yong-Hong

    2017-11-01

    With the rapid development of mechanical equipment, the mechanical health monitoring field has entered the era of big data. However, the method of manual feature extraction has the disadvantages of low efficiency and poor accuracy, when handling big data. In this study, the research object was the asynchronous motor in the drivetrain diagnostics simulator system. The vibration signals of different fault motors were collected. The raw signal was pretreated using short time Fourier transform (STFT) to obtain the corresponding time-frequency map. Then, the feature of the time-frequency map was adaptively extracted by using a convolutional neural network (CNN). The effects of the pretreatment method, and the hyper parameters of network diagnostic accuracy, were investigated experimentally. The experimental results showed that the influence of the preprocessing method is small, and that the batch-size is the main factor affecting accuracy and training efficiency. By investigating feature visualization, it was shown that, in the case of big data, the extracted CNN features can represent complex mapping relationships between signal and health status, and can also overcome the prior knowledge and engineering experience requirement for feature extraction, which is used by traditional diagnosis methods. This paper proposes a new method, based on STFT and CNN, which can complete motor fault diagnosis tasks more intelligently and accurately.

  1. Activation analysis with neutron generators using short-lived radionuclides

    International Nuclear Information System (INIS)

    Salma, I.

    1993-01-01

    The short half-life involves a number of important differences in production, transportation and measurement of radionuclides, and in counting statistics as compared with those in traditional activation analysis. Experiments were performed to investigate the analytical possibilities and prospective utilization of short-lived radionuclides produced by 14-MeV neutron irradiation. A rapid pneumatic transfer system for use with neutron generators was installed and applied for detecting radionuclides with a half-life from 300 ms to 30 s. The transport time for samples with a total mass of 1-4 g is between 130 and 160 ms for pressurized air of 0.1-0.4 MPa. 11 elements were studied by the conventional activation method using both a typical pneumatic transport system (run time 3 s) and the fast pneumatic transport facility. The effect of the cyclic activation technique on the elemental sensitivities was also investigated. (orig.)

  2. Retrospective analysis of survival rates and marginal bone loss on short implants in the mandible.

    Science.gov (United States)

    Draenert, Florian G; Sagheb, Keyvan; Baumgardt, Katharina; Kämmerer, Peer W

    2012-09-01

    Short implants have become an interesting alternative to bone augmentation in dental implantology. Design of shorter implants and longer surveillance times are a current research issue. The goal of this study was to show the survival rates of short implants below 9 mm in the partly edentulous mandibular premolar and molar regions with fixed prosthetics. Marginal vertical and 2D bone loss was evaluated additionally. Different implant designs are orientationally evaluated. A total of 247 dental implants with fixed prosthetics (crowns and bridges) in the premolar and molar region of the mandible were evaluated; 47 implants were 9 mm or shorter. Patient data were evaluated to acquire implant survival rates, implant diameter, gender and age. Panoramic X-rays were analysed for marginal bone loss. Average surveillance time was 1327 days. Cumulative survival rate (CSR) of short implants was 98% (1 implants lost) compared to 94% in the longer implants group without significance. Thirty-five of the short implants were Astratech (0 losses) and 12 were Camlog Screw Line Promote Plus (1 loss). Early vertical and two-dimensional marginal bone loss was not significantly different in short and regular length implant group with an average of 0.6 mm and 0.7 mm(2) in short implants over the observation period. Within the limitations of this study, we conclude that short implants with a length of 9 mm or less have equal survival rates compared with longer implants over the observation period of 1-3 years. © 2011 John Wiley & Sons A/S.

  3. Comparing of the Reaction Time in Substance-Dependent and Non-Dependent Individuals

    Directory of Open Access Journals (Sweden)

    Mohammad Narimani

    2012-11-01

    Full Text Available Aim: The aim of this study was to compare the simple, selective, and discrimination reaction time in substance-dependent and non-dependent individuals. Method: In this causal-comparative study, the population included of 425 males (opium and crystal dependents who were referred to addiction rehabilitation centers in Tabriz. By random sampling, 16 opium dependents, 16 crystal dependents, and 16 non-dependent individuals with no history of dependency as the compare group were selected. All groups peered in age, and marital status. For gathering data, “Addicts Admit Questionnaire” and laboratory device known as the "Reaction Time Assay" have been used. Results: The results of this study showed that there are significant differences among all groups in simple reaction time, choice reaction time and reaction time to auditory stimuli, but no significant difference in discrimination reaction time and reaction time to visual stimulus observed. Conclusion: The reaction time of substance-dependent groups is slower than non-dependent groups.

  4. Phase I study of short-time oxaliplatin, capecitabine and epirubicin (EXE) as first line therapy in patients with non-resectable gastric cancer

    DEFF Research Database (Denmark)

    Dupont, Jeanette; Jensen, Helle A; Jensen, Benny V

    2007-01-01

    A phase I trial of short-time oxaliplatin (E), capecitabine (X) and epirubicin (E) for patients with metastatic gastric cancer was initiated to establish the recommended dose for further therapy with short-time EXE. Patients received out-patient therapy with a fixed dose of epirubicin 50 mg/m2 day......-8), median survival was 9.2 months and median TTP was 7.5 months. A combination of epirubicin 50 mg/m2 day 1, capecitabine 1,000 mg/m2 continuously and oxaliplatin 130 mg/m2 day 1 each 3 weeks is an easily administered and well tolerated out-patient regimen for patients with non-resectable gastric cancer....

  5. Effectiveness of Combined Tear Film Therapy in Patients with Evaporative Dry Eye with Short Tear Film Breakup Time.

    Science.gov (United States)

    Kim, Yung Hui; Kang, Yeon Soo; Lee, Hyo Seok; Choi, Won; You, In Cheon; Yoon, Kyung Chul

    2017-10-01

    The aim of this study was to evaluate the effectiveness of combined tear film therapy targeted to aqueous, mucin, and lipid layers in patients with refractory evaporative dry eye (EDE) with short tear film breakup time (TBUT). The patients who had EDE with short TBUT and severe symptoms refractory to artificial tears were treated with hyaluronic acid (HA) 0.15% and diquafosol tetrasodium (DQS) 3% (Group 1), HA and carbomer-based lipid-containing eyedrops (Liposic EDO Gel, LPO) (Group 2), or HA, DQS, and LPO (Group 3). Ocular Surface Disease Index (OSDI) score, visual analog scale (VAS) symptom score, TBUT, Schirmer score, and corneal and conjunctival staining scores were evaluated, and noninvasive tear film breakup time (NIBUT) and tear meniscus height were measured using Keratograph ® 5 M before and 1 and 3 months after treatment. OSDI scores, VAS scores, TBUT, and NIBUT were improved at 1 and 3 months after treatment in all groups (all P film layers was most effective in improving ocular symptoms and tear film quality.

  6. Long versus short cephalomedullary nail for trochanteric femur fractures (OTA 31-A1, A2 and A3): a systematic review.

    Science.gov (United States)

    Dunn, John; Kusnezov, Nicholas; Bader, Julia; Waterman, Brian R; Orr, Justin; Belmont, Philip J

    2016-12-01

    Both long and short cephalomedullary nails (CMN) may be used to treat trochanteric femur fractures. The objective of this paper was to compare the clinical outcomes between long and short CMN in the treatment of trochanteric hip fractures. A literature search was performed, identifying 135 papers; 4 of which met inclusion and exclusion criteria. Papers included were those that compared cohorts of long and short nails for stable trochanteric femur fractures of level III evidence or superior. Data was pooled and analyzed, focusing on reoperation rate, secondary femoral shaft fracture rate, estimated blood loss, transfusion rate, operative time and length of stay. Included in the analysis were 1276 patients, with 438 short and 838 long CMN. The average age was 82.0 years for short CMN and 79.0 years for long CMN (P = 0.0002). The average follow up was 18 months, 46 % were male, and 71 % had an ASA (American Society of Anesthesiologists score) classification ≥3. The rate of reoperation was 5.0 % and 3.8 % for short and long CMN, respectively (P = 0.31). The rate of refracture was 1.6 % and 0.95 % for short and long CMN, respectively (P = 0.41). As compared to long nails, short nails had an average blood loss of 39 mL less (P = 0.0003), an 8.8 % decrease in transfusion rate (P = 0.07), and incurred 19 min less operative time (P trochanteric femur fractures, short CMN have a low reoperation rate while significantly decreasing operative time and estimated blood loss with the additional benefit of being cost effective. Level 3.

  7. Comparative Responsiveness of the PROMIS Pain Interference Short Forms, Brief Pain Inventory, PEG, and SF-36 Bodily Pain Subscale.

    Science.gov (United States)

    Kean, Jacob; Monahan, Patrick O; Kroenke, Kurt; Wu, Jingwei; Yu, Zhangsheng; Stump, Tim E; Krebs, Erin E

    2016-04-01

    To compare the sensitivity to change and the responsiveness to intervention of the PROMIS Pain Interference short forms, Brief Pain Inventory (BPI), 3-item PEG scale, and SF-36 Bodily Pain subscale in a sample of patients with persistent musculoskeletal pain of moderate severity. Standardized response means, standardized effect sizes, and receiver operating curve analyses were used to assess change between baseline and 3-month assessments in 250 participants who participated in a randomized clinical effectiveness trial of collaborative telecare management for moderate to severe and persistent musculoskeletal pain. The BPI, PEG, and SF-36 Bodily Pain measures were more sensitive to patient-reported global change than the PROMIS Pain Interference short forms, especially for the clinically improved group, for which the change detected by the PROMIS short forms was not statistically significant. The BPI was more responsive to the clinical intervention than the SF-36 Bodily Pain and PROMIS Pain Interference measures. Post hoc analyses exploring these findings did not suggest that differences in content or rating scale structure (number of response options or anchoring language) adequately explained the observed differences in the detection of change. In this clinical trial, the BPI and PEG measures were better able to detect change than the SF-36 Bodily Pain and PROMIS Pain Interference measures.

  8. Very short/short-term benefit of inpatient/outpatient cardiac rehabilitation programs after coronary artery bypass grafting surgery.

    Science.gov (United States)

    Spiroski, Dejan; Andjić, Mojsije; Stojanović, Olivera Ilić; Lazović, Milica; Dikić, Ana Djordjević; Ostojić, Miodrag; Beleslin, Branko; Kostić, Snežana; Zdravković, Marija; Lović, Dragan

    2017-05-01

    Exercise-based rehabilitation is an important part of treatment patients following coronary artery bypass graft (CABG) surgery. To evaluate effect of very short/short-term exercise training on cardiopulmonary exercise testing (CPET) parameters. We studied 54 consecutive patients with myocardial infarction (MI) treated with CABG surgery referred for rehabilitation. The study population consisted of 50 men and 4 women (age 57.72 ± 7.61 years, left ventricular ejection fraction 55% ± 5.81%), who participated in a 3-week clinical and 6-month outpatient cardiac rehabilitation program. The Inpatient program consisted of cycling 7 times/week and daily walking for 45 minutes. The outpatient program consisted mainly of walking 5 times/week for 45 minutes and cycling 3 times/week. All patients performed symptom-limited CPET on a bicycle ergometer with a ramp protocol of 10 W/minute at the start, for 3 weeks, and for 6 months. After 3 weeks of an exercise-based cardiac rehabilitation program, exercise tolerance improved as compared to baseline, as well as peak respiratory exchange ratio. Most importantly, peak VO 2 (16.35 ± 3.83 vs 17.88 ± 4.25 mL/kg/min, respectively, P exercise training in patients with MI treated with CABG surgery is safe and improves functional capacity. © 2017 Wiley Periodicals, Inc.

  9. Short Implants: New Horizon in Implant Dentistry.

    Science.gov (United States)

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  10. Worst Asymmetrical Short-Circuit Current

    DEFF Research Database (Denmark)

    Arana Aristi, Iván; Holmstrøm, O; Grastrup, L

    2010-01-01

    In a typical power plant, the production scenario and the short-circuit time were found for the worst asymmetrical short-circuit current. Then, a sensitivity analysis on the missing generator values was realized in order to minimize the uncertainty of the results. Afterward the worst asymmetrical...

  11. Time-of-flight depth image enhancement using variable integration time

    Science.gov (United States)

    Kim, Sun Kwon; Choi, Ouk; Kang, Byongmin; Kim, James Dokyoon; Kim, Chang-Yeong

    2013-03-01

    Time-of-Flight (ToF) cameras are used for a variety of applications because it delivers depth information at a high frame rate. These cameras, however, suffer from challenging problems such as noise and motion artifacts. To increase signal-to-noise ratio (SNR), the camera should calculate a distance based on a large amount of infra-red light, which needs to be integrated over a long time. On the other hand, the integration time should be short enough to suppress motion artifacts. We propose a ToF depth imaging method to combine advantages of short and long integration times exploiting an imaging fusion scheme proposed for color imaging. To calibrate depth differences due to the change of integration times, a depth transfer function is estimated by analyzing the joint histogram of depths in the two images of different integration times. The depth images are then transformed into wavelet domains and fused into a depth image with suppressed noise and low motion artifacts. To evaluate the proposed method, we captured a moving bar of a metronome with different integration times. The experiment shows the proposed method could effectively remove the motion artifacts while preserving high SNR comparable to the depth images acquired during long integration time.

  12. Emission Characteristics of Laser-Induced Plasma Using Collinear Long and Short Dual-Pulse Laser-Induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Wang, Zhenzhen; Deguchi, Yoshihiro; Liu, Renwei; Ikutomo, Akihiro; Zhang, Zhenzhen; Chong, Daotong; Yan, Junjie; Liu, Jiping; Shiou, Fang-Jung

    2017-09-01

    Collinear long and short dual-pulse laser-induced breakdown spectroscopy (DP-LIBS) was employed to clarify the emission characteristics from laser-induced plasma. The plasma was sustained and became stable by the long pulse-width laser with the pulse width of 60 μs under free running (FR) conditions as an external energy source. Comparing the measurement results of stainless steel in air using single-pulse LIBS (SP-LIBS) and DP-LIBS, the emission intensity was markedly enhanced using DP-LIBS. The temperature of plasma induced by DP-LIBS was maintained at a higher temperature under different gate delay time and short pulse-width laser power conditions compared with those measured using short SP-LIBS. Moreover, the variation rates of plasma temperatures measured using DP-LIBS were also lower. The superior detection ability was verified by the measurement of aluminum sample in water. The spectra were clearly detected using DP-LIBS, whereas it cannot be identified using SP-LIBS of short and long pulse widths. The effects of gate delay time and short pulse-width laser power were also discussed. These results demonstrate the feasibility and enhanced detection ability of the proposed collinear long and short DP-LIBS method.

  13. Spatial filtering velocimetry revisited: exact short-time detecting schemes from arbitrarily small-size reticles

    International Nuclear Information System (INIS)

    Ando, S; Nara, T; Kurihara, T

    2014-01-01

    Spatial filtering velocimetry was proposed in 1963 by Ator as a velocity-sensing technique for aerial camera-control systems. The total intensity of a moving surface is observed through a set of parallel-slit reticles, resulting in a narrow-band temporal signal whose frequency is directly proportional to the image velocity. However, even despite its historical importance and inherent technical advantages, the mathematical formulation of this technique is only valid when infinite-length observation in both space and time is possible, which causes significant errors in most applications where a small receptive window and high resolution in both axes are desired. In this study, we apply a novel mathematical technique, the weighted integral method, to solve this problem, and obtain exact sensing schemes and algorithms for finite (arbitrarily small but non-zero) size reticles and short-time estimation. Practical considerations for utilizing these schemes are also explored both theoretically and experimentally. (paper)

  14. Auditory short-term memory activation during score reading.

    Science.gov (United States)

    Simoens, Veerle L; Tervaniemi, Mari

    2013-01-01

    Performing music on the basis of reading a score requires reading ahead of what is being played in order to anticipate the necessary actions to produce the notes. Score reading thus not only involves the decoding of a visual score and the comparison to the auditory feedback, but also short-term storage of the musical information due to the delay of the auditory feedback during reading ahead. This study investigates the mechanisms of encoding of musical information in short-term memory during such a complicated procedure. There were three parts in this study. First, professional musicians participated in an electroencephalographic (EEG) experiment to study the slow wave potentials during a time interval of short-term memory storage in a situation that requires cross-modal translation and short-term storage of visual material to be compared with delayed auditory material, as it is the case in music score reading. This delayed visual-to-auditory matching task was compared with delayed visual-visual and auditory-auditory matching tasks in terms of EEG topography and voltage amplitudes. Second, an additional behavioural experiment was performed to determine which type of distractor would be the most interfering with the score reading-like task. Third, the self-reported strategies of the participants were also analyzed. All three parts of this study point towards the same conclusion according to which during music score reading, the musician most likely first translates the visual score into an auditory cue, probably starting around 700 or 1300 ms, ready for storage and delayed comparison with the auditory feedback.

  15. Timing matters: The processing of pitch relations

    Directory of Open Access Journals (Sweden)

    Annekathrin eWeise

    2014-06-01

    Full Text Available The human central auditory system can automatically extract abstract regularities from a variant auditory input. To this end, temporarily separated events need to be related. This study tested whether the timing between events, falling either within or outside the temporal window of integration (~350 ms, impacts the extraction of abstract feature relations. We utilized tone pairs for which tones within but not across pairs revealed a constant pitch relation (e.g. pitch of 2nd tone of a pair higher than pitch of 1st tone, while absolute pitch values varied across pairs. We measured the Mismatch Negativity (MMN; the brain’s error signal to auditory regularity violations to 2nd tones that rarely violated the pitch relation (e.g. pitch of 2nd tone lower. A Short condition in which tone duration (90 ms and stimulus onset asynchrony between the tones of a pair were short (110 ms was compared to two conditions, where this onset asynchrony was long (510 ms. In the Long Gap condition the tone durations were identical to Short (90 ms, but the silent interval was prolonged by 400 ms. In Long Tone the duration of the first tone was prolonged by 400 ms, while the silent interval was comparable to Short (20 ms. Results show a frontocentral MMN of comparable amplitude in all conditions. Thus, abstract pitch relations can be extracted even when the within-pair timing exceeds the integration period. Source analyses indicate MMN generators in the supratemporal cortex. Interestingly, they were located more anterior in Long Gap than in Short and Long Tone. Moreover, frontal generator activity was found for Long Gap and Long Tone. Thus, the way in which the system automatically registers irregular abstract pitch relations depends on the timing of the events to be linked. Pending that the current MMN data mirror established abstract rule representations coding the regular pitch relation, neural processes building these templates vary with timing.

  16. Timing matters: the processing of pitch relations

    Science.gov (United States)

    Weise, Annekathrin; Grimm, Sabine; Trujillo-Barreto, Nelson J.; Schröger, Erich

    2014-01-01

    The human central auditory system can automatically extract abstract regularities from a variant auditory input. To this end, temporarily separated events need to be related. This study tested whether the timing between events, falling either within or outside the temporal window of integration (~350 ms), impacts the extraction of abstract feature relations. We utilized tone pairs for which tones within but not across pairs revealed a constant pitch relation (e.g., pitch of second tone of a pair higher than pitch of first tone, while absolute pitch values varied across pairs). We measured the mismatch negativity (MMN; the brain’s error signal to auditory regularity violations) to second tones that rarely violated the pitch relation (e.g., pitch of second tone lower). A Short condition in which tone duration (90 ms) and stimulus onset asynchrony between the tones of a pair were short (110 ms) was compared to two conditions, where this onset asynchrony was long (510 ms). In the Long Gap condition, the tone durations were identical to Short (90 ms), but the silent interval was prolonged by 400 ms. In Long Tone, the duration of the first tone was prolonged by 400 ms, while the silent interval was comparable to Short (20 ms). Results show a frontocentral MMN of comparable amplitude in all conditions. Thus, abstract pitch relations can be extracted even when the within-pair timing exceeds the integration period. Source analyses indicate MMN generators in the supratemporal cortex. Interestingly, they were located more anterior in Long Gap than in Short and Long Tone. Moreover, frontal generator activity was found for Long Gap and Long Tone. Thus, the way in which the system automatically registers irregular abstract pitch relations depends on the timing of the events to be linked. Pending that the current MMN data mirror established abstract rule representations coding the regular pitch relation, neural processes building these templates vary with timing. PMID:24966823

  17. Fetal short time variation during labor: a non-invasive alternative to fetal scalp pH measurements?

    OpenAIRE

    Schiermeier, Sven; Reinhard, Joscha; Hatzmann, Hendrike; Zimmermann, Ralf C.; Westhof, Gregor

    2009-01-01

    Objective: To determine whether short time variation (STV) of fetal heart beat correlates with scalp pH measurements during labor. Patients and methods: From 1279 deliveries, 197 women had at least one fetal scalp pH measurement. Using the CTG-Player®, STVs were calculated from the electronically saved cardiotocography (CTG) traces and related to the fetal scalp pH measurements. Results: There was no correlation between STV and fetal scalp pH measurements (r=−0.0592). Conclusions: Fetal ST...

  18. Comparing Two Antibacterial Treatments for Bioceramic Coatings at Short Culture Times

    Science.gov (United States)

    Melero, H.; Madrid, C.; Fernández, J.; Guilemany, J. M.

    2014-04-01

    Plasma-sprayed hydroxyapatite coatings were employed industrially for decades to improve osteointegration of articular implants, but many studies have warned about the problems inherent to this procedure (mechanical properties, harmful phases). Consequently, a combination of hydroxyapatite with TiO2 sprayed by high velocity oxy-fuel spray was considered in this study. As infection after joint replacement surgery is one of the most critical concerns when considering implant performance, it is necessary to study possible ways to reduce or eliminate it. Two coating treatments were chosen for this study: addition of a percentage of ZnO and immersion in gentamicin for 24 h. Furthermore, three bacteria were considered: Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus. The evolution of bacteria viability in solution was measured at 0, 2, and 4 h; and plate assays were performed to study antibacterial effects by diffusion. The results show an important antibacterial effect of the as-sprayed coating, attributed to the presence of -OH radicals on the surface. The presence of ZnO did not have any additional influence on bacteria viability, but gentamicin-treated samples showed an improvement in antibacterial behavior for Gram-negative bacteria in solution, as well as a bactericidal effect in diffusion conditions.

  19. Role of short-acting nitroglycerin in the management of ischemic heart disease

    Science.gov (United States)

    Boden, William E; Padala, Santosh K; Cabral, Katherine P; Buschmann, Ivo R; Sidhu, Mandeep S

    2015-01-01

    Nitroglycerin is the oldest and most commonly prescribed short-acting anti-anginal agent; however, despite its long history of therapeutic usage, patient and health care provider education regarding the clinical benefits of the short-acting formulations in patients with angina remains under-appreciated. Nitrates predominantly induce vasodilation in large capacitance blood vessels, increase epicardial coronary arterial diameter and coronary collateral blood flow, and impair platelet aggregation. The potential for the prophylactic effect of short-acting nitrates remains an under-appreciated part of optimal medical therapy to reduce angina and decrease myocardial ischemia, thereby enhancing the quality of life. Short-acting nitroglycerin, administered either as a sublingual tablet or spray, can complement anti-anginal therapy as part of optimal medical therapy in patients with refractory and recurrent angina either with or without myocardial revascularization, and is most commonly used to provide rapid therapeutic relief of acute recurrent angina attacks. When administered prophylactically, both formulations increase angina-free walking time on treadmill testing, abolish or delay ST segment depression, and increase exercise tolerance. The sublingual spray formulation provides several clinical advantages compared to tablet formulations, including a lower incidence of headache and superiority to the sublingual tablet in terms of therapeutic action and time to onset, while the magnitude and duration of vasodilatory action appears to be comparable. Furthermore, the sublingual spray formulation may be advantageous to tablet preparations in patients with dry mouth. This review discusses the efficacy and utility of short-acting nitroglycerin (sublingual spray and tablet) therapy for both preventing and aborting an acute angina attack, thereby leading to an improved quality of life. PMID:26316714

  20. Comparative study in LTC Combustion between a short HP EGR loop without cooler and a variable lift and duration system

    Energy Technology Data Exchange (ETDEWEB)

    Bression, Guillaume; Pacaud, Pierre; Soleri, Dominique; Cessou, Jerome [IFP (France); Azoulay, David [Renault Powertrain Div. (France); Lawrence, David [Mechadyne (United Kingdom); Doradoux, Laurent; Guerrassi, Noureddine [Delphi Diesel Systems (France)

    2008-07-01

    In order to reach future Diesel emission standards such as Euro 6 or Tier 2 Bin 5, NO{sub x} emissions need to be dramatically reduced. Advanced technologies and engine settings such as higher EGR rates, reduced compression ratio, EGR cooler and low-pressure EGR loop - depending on vehicle application - may help to reach this target whilst maintaining low CO{sub 2} emissions and fuel consumption. However, the resulting low combustion temperatures and the low air-fuel ratios lead to a significant increase in HC and CO emissions, especially during the start-up phase prior to catalyst light-off. Moreover, high levels of EGR make transient operation even more difficult. So HC-CO emissions and EGR transient operation represent two key issues that could limit the extension of this alternative combustion mode. Consequently, an in-depth investigation of a variable lift and duration (VLD) system was performed to overcome these problems on a 4-cylinder engine, which was also equipped with a dual HP-LP EGR loop. The VLD system tested in this paper produces a variable camshaft-operated exhaust valve re-opening, which is controlled by a hydraulic rotary actuator, ensuring quick and accurate regulation of the internal gas recirculation (IGR). By increasing gas temperature in the combustion chamber, this advanced technology allows us to reduce HC-CO emissions by 50% under 3 bar BMEP. Although efficient, this technology has to be compared with other solutions from a cost-to-value point of view. The aim of this paper is firstly to compare the double lift exhaust system with a short route high-performance EGR loop without cooler by quantifying their respective gains on steady state points of the NEDC cycle, then by evaluating their potential performances during transient conditions. With the short-route EGR, the potential in HC-CO emission reduction remains significant on a large scale of engine temperatures representative of engine warm up. However, the VLD system allows us to

  1. Modelling and Comparative Performance Analysis of a Time-Reversed UWB System

    Directory of Open Access Journals (Sweden)

    Popovski K

    2007-01-01

    Full Text Available The effects of multipath propagation lead to a significant decrease in system performance in most of the proposed ultra-wideband communication systems. A time-reversed system utilises the multipath channel impulse response to decrease receiver complexity, through a prefiltering at the transmitter. This paper discusses the modelling and comparative performance of a UWB system utilising time-reversed communications. System equations are presented, together with a semianalytical formulation on the level of intersymbol interference and multiuser interference. The standardised IEEE 802.15.3a channel model is applied, and the estimated error performance is compared through simulation with the performance of both time-hopped time-reversed and RAKE-based UWB systems.

  2. Comparison of short-term rainfall forecasts for modelbased flow prediction in urban drainage systems

    DEFF Research Database (Denmark)

    Thorndahl, Søren; Ahm, Malte; Nielsen, Jesper Ellerbek

    2013-01-01

    Forecast-based flow prediction in drainage systems can be used to implement real-time control of drainage systems. This study compares two different types of rainfall forecast - a radar rainfall extrapolation-based nowcast model and a numerical weather prediction model. The models are applied...... performance of the system is found using the radar nowcast for the short lead times and the weather model for larger lead times....

  3. Short-time relaxation of the critical current in oriented grained YBa2Cu3Ox and granular (Bi,Pb)2 Sr2Ca2Cu3Ox

    International Nuclear Information System (INIS)

    Kuepfer, H.; Keller, C.; Meier-Hirmer, R.; Wiech, U.; Salama, K.; Selvamanickam, V.; Green, S.M.; Luo, H.L.; Politis, C.

    1990-01-01

    The time-dependent behavior of the critical current density j c is investigated by ac inductive measurements. The variation of db/dt of the ac field between 0.1 and 3 T/s reveals a short-time relaxation in the millisecond regime before j c exhibits the familiar logarithmic decay. At fields above the irreversibility line only this short-time relaxation is observed. Our experimental time scale allows us to obtain the unrelaxed critical current density j c0 at certain fields and temperatures

  4. Effect of low-temperature long-time and high-temperature short-time blanching and frying treatments on the French fry quality of six Irish potato cultivars.

    Science.gov (United States)

    Ngobese, Nomali Ziphorah; Workneh, Tilahun Seyoum; Siwela, Muthulisi

    2017-02-01

    Processing conditions are an important determinant of French fry quality. However, the effect of low-temperature long-time (LTLT) and high-temperature short-time (HTST) blanching and frying treatments has not been investigated in many cultivars. The current study investigates the effect of the sequential application of these treatments on French fries processed from six Irish potato cultivars (Fianna, Innovator, Mondial, Navigator, Panamera and Savanna). Blanching was effected at 75 °C for 10 min or 85 °C for 5 min and frying was effected at 160 °C for 2 min or 180 °C for 1 min. These treatments resulted in significant differences in the quality of the fries across the cultivars. The blanching treatments had a greater impact on the French fry quality than the frying treatments. LTLT blanching resulted in lower oil (12-13% fresh mass basis [fmb]), and higher protein (3.5-4.3% fmb) and mineral content in the French fries processed from Innovator, compared to HTST blanching. This was accompanied by a crispier crust, which required a greater puncture force (1.2-2.1 N) for penetration. Blanching with the LTLT treatment before HTST frying resulted in French fries that were the most acceptable to consumers and these were from Fianna, Innovator and Mondial. The current study demonstrates that the effect of French fry processing conditions is cultivar-dependent.

  5. Comparative Evaluations of Four Specification Methods for Real-Time Systems

    Science.gov (United States)

    1989-12-01

    December 1989 Comparative Evaluations of Four Specification Methods for Real - Time Systems David P. Wood William G. Wood Specification and Design Methods...Methods for Real - Time Systems Abstract: A number of methods have been proposed in the last decade for the specification of system and software requirements...and software specification for real - time systems . Our process for the identification of methods that meet the above criteria is described in greater

  6. Short-cut math

    CERN Document Server

    Kelly, Gerard W

    1984-01-01

    Clear, concise compendium of about 150 time-saving math short-cuts features faster, easier ways to add, subtract, multiply, and divide. Each problem includes an explanation of the method. No special math ability needed.

  7. Comparing the short and long term stability of biodegradable, ceramic and cation exchange membranes in microbial fuel cells.

    Science.gov (United States)

    Winfield, Jonathan; Chambers, Lily D; Rossiter, Jonathan; Ieropoulos, Ioannis

    2013-11-01

    The long and short-term stability of two porous dependent ion exchange materials; starch-based compostable bags (BioBag) and ceramic, were compared to commercially available cation exchange membrane (CEM) in microbial fuel cells. Using bi-directional polarisation methods, CEM exhibited power overshoot during the forward sweep followed by significant power decline over the reverse sweep (38%). The porous membranes displayed no power overshoot with comparably smaller drops in power during the reverse sweep (ceramic 8%, BioBag 5.5%). The total internal resistance at maximum power increased by 64% for CEM compared to 4% (ceramic) and 6% (BioBag). Under fixed external resistive loads, CEM exhibited steeper pH reductions than the porous membranes. Despite its limited lifetime, the BioBag proved an efficient material for a stable microbial environment until failing after 8 months, due to natural degradation. These findings highlight porous separators as ideal candidates for advancing MFC technology in terms of cost and operation stability. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Characterization of new eye drops with choline salicylate and assessment of their irritancy by in vitro short time exposure tests.

    Science.gov (United States)

    Wroblewska, Katarzyna; Kucinska, Małgorzata; Murias, Marek; Lulek, Janina

    2015-09-01

    The aim of our study was to examine the irritation potential of new eye drops containing 2% choline salicylate (CS) as an active pharmaceutical ingredient (API) and various polymers increasing eye drop viscosity (hydroxyethylcellulose, hydroxypropyl methylcellulose, methylcellulose, polyvinyl alcohol, polyvinylpyrrolidone). The standard method for assessing the potential of irritating substances has been the Draize rabbit eye test. However the European Centre for Validation of Alternative Methods and the Coordinating Committee for Validation of Alternative Methods recommend, short time exposure (STE) in vitro tests as an alternative method for assessing eye irritation. The eye irritation potential was determined using cytotoxicity test methods for rabbit corneal cell line (SIRC) after 5 min exposure. The viability of cells was determined using two cytotoxicity assays: MTT and Neutral Red Uptake. According to the irritation rankings for the short time exposure test, all tested eye drops are classified as non-irritating (cell viability >70%).

  9. Application of rat mast cell incubates as a possible short-time test for sensitizing occupational chemicals

    Energy Technology Data Exchange (ETDEWEB)

    Diel, F.; Neidhart, B.; Opree, W.

    1981-08-01

    The direct action of sensitizing occupational chemicals (formaldehyde, phenol, phenylhydrazine, p-aminophenol) on rat mast cells was investigated by determination of histamine using HPLC separation and fluorimetric detection. It turned out that dispersed mast cells from immunized and non-immunized Wistar-rats are more sensitive than small-cut lung tissue slices. Passive cutaneous anaphylaxis was negative after a fortnight sensitizing experiment with the here described occupational chemicals. Short-time tests with rat mast cells reflect anaphylactoid response and are suitable for the screening of sensitizing chemicals.

  10. 2-Hydroxyglutarate Detection by Short Echo Time Magnetic Resonance Spectroscopy in Routine Imaging Study of Brain Glioma at 3.0 T.

    Science.gov (United States)

    Crisi, Girolamo; Filice, Silvano; Michiara, Maria; Crafa, Pellegrino; Lana, Silvia

    The objective of this study was to assess the effective performance of short echo time magnetic resonance spectroscopy (short TE MRS) for 2HG detection as biomarker of isocitrate dehydrogenase (IDH) status in all grade glioma (GL). A total of 82 GL patients were prospectively investigated by short TE MRS at 3.0 T as part of a multimodal magnetic resonance imaging study protocol. Spectral analysis was performed using linear combination model. Tumor specimens were diagnosed as IDH mutant or wild type according to the 2016 World Health Organization (WHO) classification of brain tumors. Spectra were analyzed for the presence of 2HG. The performance of short TE MRS was evaluated in terms of sensitivity, specificity, and positive and negative likelihood ratio on the overall sample and on GL WHO grades II and III and glioblastoma separately. The specificity and sensitivity estimated on the overall sample were 88% and 77%, respectively. In GL WHO grades II and III, 100% specificity and 75% sensitivity were estimated. We reiterate the feasibility to identify IDH status of brain GL using short TE MRS at 3.0 T. The method can correctly detect 2HG as expression of IDH mutation in WHO grades II and III GL with a 100% specificity but a 75% sensitivity. In the evaluation of glioblastoma, short TE MRS performs poorly having a 17% false positive rate.

  11. Measurement of short transverse relaxation times by pseudo-echo nutation experiments

    Science.gov (United States)

    Ferrari, Maude; Moyne, Christian; Canet, Daniel

    2018-07-01

    Very short NMR transverse relaxation times may be difficult to measure by conventional methods. Nutation experiments constitute an alternative approach. Nutation is, in the rotating frame, the equivalent of precession in the laboratory frame. It consists in monitoring the rotation of magnetization around the radio-frequency (rf) field when on-resonance conditions are fulfilled. Depending on the amplitude of the rf field, nutation may be sensitive to the two relaxation rates R1 and R2. A full theoretical development has been worked out for demonstrating how these two relaxation rates could be deduced from a simple nutation experiment, noticing however that inhomogeneity of the rf field may lead to erroneous results. This has led us to devise new experiments which are the equivalent of echo techniques in the rotating frame (pseudo spin-echo nutation experiment and pseudo gradient-echo experiment). Full equations of motion have been derived. Although complicated, they indicate that the sum of the two relaxation rates can be obtained very accurately and not altered by rf field inhomogeneity. This implies however an appropriate data processing accounting for the oscillations which are superposed to the echo decays and, anyway, theoretically predicted. A series of experiments has been carried out for different values of the rf field amplitude on samples of water doped with a paramagnetic compound at different concentrations. Pragmatically, as R1 can be easily measured by conventional methods, its value is entered in the data processing algorithm which then returns exclusively the value of the transverse relaxation time. Very consistent results are obtained that way.

  12. Time-dependent H-like and He-like Al lines produced by ultra-short pulse laser

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Takako; Kato, Masatoshi [National Inst. for Fusion Science, Nagoya (Japan); Shepherd, R; Young, B; More, R; Osterheld, Al

    1998-03-01

    We have performed numerical modeling of time-resolved x-ray spectra from thin foil targets heated by the LLNL Ultra-short pulse (USP) laser. The targets were aluminum foils of thickness ranging from 250 A to 1250 A, heated with 120 fsec pulses of 400 nm light from the USP laser. The laser energy was approximately 0.2 Joules, focused to a 3 micron spot size for a peak intensity near 2 x 10{sup 19} W/cm{sup 2}. Ly{alpha} and He{alpha} lines were recorded using a 900 fsec x-ray streak camera. We calculate the effective ionization, recombination and emission rate coefficients including density effects for H-like and He-like aluminum ions using a collisional radiative model. We calculate time-dependent ion abundances using these effective ionization and recombination rate coefficients. The time-dependent electron temperature and density used in the calculation are based on an analytical model for the hydrodynamic expansion of the target foils. During the laser pulse the target is ionized. After the laser heating stops, the plasma begins to recombine. Using the calculated time dependent ion abundances and the effective emission rate coefficients, we calculate the time dependent Ly{alpha} and He{alpha} lines. The calculations reproduce the main qualitative features of the experimental spectra. (author)

  13. Development of a New Class of Scintillating Fibres with Very Short Decay Time and High Light Yield

    International Nuclear Information System (INIS)

    Borshchev, O.; Ponomarenko, S.; Surin, N.; Cavalcante, A.B.R.; Gavardi, L.; Gruber, L.; Joram, C.; Shinji, O.

    2017-01-01

    We present first studies of a new class of scintillating fibres which are characterised by very short decay times and high light yield. The fibres are based on a novel type of luminophores admixed to a polystyrene core matrix. These so-called Nanostructured Organosilicon Luminophores (NOL) have high photoluminescense quantum yield and decay times just above 1 ns. A blue and a green emitting prototype fibre with 250 μm diameter were produced and characterised in terms of attenuation length, ionisation light yield, decay time and tolerance to x-ray irradiation. The well-established Kuraray SCSF-78 and SCSF-3HF fibres were taken as references. Even though the two prototype fibres mark just an intermediate step in an ongoing development, their performance is already on a competitive level. In particular, their decay time constants are about a factor of two shorter than the fastest known fibres, which makes them promising candidates for time critical applications.

  14. Changes in Children's Perception-Action Tuning over Short Time Scales: Bicycling across Traffic-Filled Intersections in a Virtual Environment

    Science.gov (United States)

    Plumert, Jodie M.; Kearney, Joseph K.; Cremer, James F.; Recker, Kara M.; Strutt, Jonathan

    2011-01-01

    This investigation examined short-term changes in child and adult cyclists' gap decisions and movement timing in response to general and specific road-crossing experiences. Children (10- and 12-year-olds) and adults rode a bicycle through a virtual environment with 12 intersections. Participants faced continuous cross traffic and waited for gaps…

  15. Dynamics of Al/Fe{sub 2}O{sub 3} MIC combustion from short single-pulse photothermal initiation and time-resolved spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Stiegman, Albert E.; Park, Chi-Dong; Mileham, Melissa; Van de Burgt, Lambertus J. [Department of Chemistry and Biochemistry, Florida State University Tallahassee, FL (United States); Kramer, Michael P. [AFRL/MNME Eglin AFB, FL (United States)

    2009-08-15

    Time-resolved spectroscopy was used to study the dynamics of the photothermal ignition of Al/Fe{sub 2}O{sub 3} metastable intermolecular composites after single short-pulse laser initiation. The dynamics were recorded in several time domains from nanosecond to microsecond to quantify the dynamics from initial laser excitation to combustion. Time-averaged spectral data were also collected for the overall emission occurring during combustion. (Abstract Copyright [2009], Wiley Periodicals, Inc.)

  16. Effects of stress on heart rate complexity—A comparison between short-term and chronic stress

    OpenAIRE

    Schubert, C.; Lambertz, M.; Nelesen, R.A.; Bardwell, W.; Choi, J.-B.; Dimsdale, J.E.

    2008-01-01

    This study examined chronic and short-term stress effects on heart rate variability (HRV), comparing time, frequency and phase domain (complexity) measures in 50 healthy adults. The hassles frequency subscale of the combined hassles and uplifts scale (CHUS) was used to measure chronic stress. Short-term stressor reactivity was assessed with a speech task. HRV measures were determined via surface electrocardiogram (ECG). Because respiration rate decreased during the speech task (p < .001), thi...

  17. Multifractals embedded in short time series: An unbiased estimation of probability moment

    Science.gov (United States)

    Qiu, Lu; Yang, Tianguang; Yin, Yanhua; Gu, Changgui; Yang, Huijie

    2016-12-01

    An exact estimation of probability moments is the base for several essential concepts, such as the multifractals, the Tsallis entropy, and the transfer entropy. By means of approximation theory we propose a new method called factorial-moment-based estimation of probability moments. Theoretical prediction and computational results show that it can provide us an unbiased estimation of the probability moments of continuous order. Calculations on probability redistribution model verify that it can extract exactly multifractal behaviors from several hundred recordings. Its powerfulness in monitoring evolution of scaling behaviors is exemplified by two empirical cases, i.e., the gait time series for fast, normal, and slow trials of a healthy volunteer, and the closing price series for Shanghai stock market. By using short time series with several hundred lengths, a comparison with the well-established tools displays significant advantages of its performance over the other methods. The factorial-moment-based estimation can evaluate correctly the scaling behaviors in a scale range about three generations wider than the multifractal detrended fluctuation analysis and the basic estimation. The estimation of partition function given by the wavelet transform modulus maxima has unacceptable fluctuations. Besides the scaling invariance focused in the present paper, the proposed factorial moment of continuous order can find its various uses, such as finding nonextensive behaviors of a complex system and reconstructing the causality relationship network between elements of a complex system.

  18. Uncovering the mutation-fixation correlation in short lineages

    Directory of Open Access Journals (Sweden)

    Vallender Eric J

    2007-09-01

    Full Text Available Abstract Background We recently reported a highly unexpected positive correlation between the fixation probability of nonsynonymous mutations (estimated by ω and neutral mutation rate (estimated by Ks in mammalian lineages. However, this positive correlation was observed for lineages with relatively long divergence time such as the human-mouse lineage, and was not found for very short lineages such as the human-chimpanzee lineage. It was previously unclear how to interpret this discrepancy. It may indicate that the positive correlation between ω and Ks in long lineages is a false finding. Alternatively, it may reflect a biologically meaningful difference between various lineages. Finally, the lack of positive correlation in short lineages may be the result of methodological artifacts. Results Here we show that a strong positive correlation can indeed be seen in short lineages when a method was introduced to correct for the inherently high levels of stochastic noise in the use of Ks as an estimator of neutral mutation rate. Thus, the previously noted lack of positive correlation between ω and Ks in short lineages is due to stochastic noise in Ks that makes it a far less reliable estimator of neutral mutation rate in short lineages as compared to long lineages. Conclusion A positive correlation between ω and Ks can be observed in all mammalian lineages for which large amounts of sequence data are available, including very short lineages. It confirms the authenticity of this highly unexpected correlation, and argues that the correction likely applies broadly across all mammals and perhaps even non-mammalian species.

  19. Hospitalisation in an emergency department short-stay unit compared to an internal medicine department is associated with fewer complications in older patients - an observational study

    DEFF Research Database (Denmark)

    Strøm, Camilla; Mollerup, Talie Khadem; Kromberg, Laurits Schou

    2017-01-01

    Medicine Department (IMD). METHODS: Observational study evaluating adverse events during hospitalisation in non-emergent, age-matched, internal medicine patients ≥75 years, acutely admitted to either the SSU or the IMD at Holbaek Hospital, Denmark, from January to August, 2014. Medical records were......, unplanned readmission, and nosocomial infection. CONCLUSIONS: Adverse events of hospitalisation were significantly less common in older patients acutely admitted to an Emergency Department Short-stay Unit as compared to admission to an Internal Medicine Department.......BACKGROUND: Older patients are at particular risk of experiencing adverse events during hospitalisation. OBJECTIVE: To compare the frequencies and types of adverse events during hospitalisation in older persons acutely admitted to either an Emergency Department Short-stay Unit (SSU) or an Internal...

  20. Energy expenditure of sedentary screen time compared with active screen time for children.

    Science.gov (United States)

    Lanningham-Foster, Lorraine; Jensen, Teresa B; Foster, Randal C; Redmond, Aoife B; Walker, Brian A; Heinz, Dieter; Levine, James A

    2006-12-01

    We examined the effect of activity-enhancing screen devices on children's energy expenditure compared with performing the same activities while seated. Our hypothesis was that energy expenditure would be significantly greater when children played activity-promoting video games, compared with sedentary video games. Energy expenditure was measured for 25 children aged 8 to 12 years, 15 of whom were lean, while they were watching television seated, playing a traditional video game seated, watching television while walking on a treadmill at 1.5 miles per hour, and playing activity-promoting video games. Watching television and playing video games while seated increased energy expenditure by 20 +/- 13% and 22 +/- 12% above resting values, respectively. When subjects were walking on the treadmill and watching television, energy expenditure increased by 138 +/- 40% over resting values. For the activity-promoting video games, energy expenditure increased by 108 +/- 40% with the EyeToy (Sony Computer Entertainment) and by 172 +/- 68% with Dance Dance Revolution Ultramix 2 (Konami Digital Entertainment). Energy expenditure more than doubles when sedentary screen time is converted to active screen time. Such interventions might be considered for obesity prevention and treatment.

  1. Distribution of Short-Term and Lifetime Predicted Risks of Cardiovascular Diseases in Peruvian Adults

    Science.gov (United States)

    Quispe, Renato; Bazo-Alvarez, Juan Carlos; Burroughs Peña, Melissa S; Poterico, Julio A; Gilman, Robert H; Checkley, William; Bernabé-Ortiz, Antonio; Huffman, Mark D; Miranda, J Jaime

    2015-01-01

    Background Short-term risk assessment tools for prediction of cardiovascular disease events are widely recommended in clinical practice and are used largely for single time-point estimations; however, persons with low predicted short-term risk may have higher risks across longer time horizons. Methods and Results We estimated short-term and lifetime cardiovascular disease risk in a pooled population from 2 studies of Peruvian populations. Short-term risk was estimated using the atherosclerotic cardiovascular disease Pooled Cohort Risk Equations. Lifetime risk was evaluated using the algorithm derived from the Framingham Heart Study cohort. Using previously published thresholds, participants were classified into 3 categories: low short-term and low lifetime risk, low short-term and high lifetime risk, and high short-term predicted risk. We also compared the distribution of these risk profiles across educational level, wealth index, and place of residence. We included 2844 participants (50% men, mean age 55.9 years [SD 10.2 years]) in the analysis. Approximately 1 of every 3 participants (34% [95% CI 33 to 36]) had a high short-term estimated cardiovascular disease risk. Among those with a low short-term predicted risk, more than half (54% [95% CI 52 to 56]) had a high lifetime predicted risk. Short-term and lifetime predicted risks were higher for participants with lower versus higher wealth indexes and educational levels and for those living in urban versus rural areas (PPeruvian adults were classified as low short-term risk but high lifetime risk. Vulnerable adults, such as those from low socioeconomic status and those living in urban areas, may need greater attention regarding cardiovascular preventive strategies. PMID:26254303

  2. The use of Matlab for colour fuzzy representation of multichannel EEG short time spectra.

    Science.gov (United States)

    Bigan, C; Strungaru, R

    1998-01-01

    During the last years, a lot of EEG research efforts was directed to intelligent methods for automatic analysis of data from multichannel EEG recordings. However, all the applications reported were focused on specific single tasks like detection of one specific "event" in the EEG signal: spikes, sleep spindles, epileptic seizures, K complexes, alpha or other rhythms or even artefacts. The aim of this paper is to present a complex system being able to perform a representation of the dynamic changes in frequency components of each EEG channel. This representation uses colours as a powerful means to show the only one frequency range chosen from the shortest epoch of signal able to be processed with the conventional "Short Time Fast Fourier Transform" (S.T.F.F.T.) method.

  3. Flight time, number of sectors and risk of low back pain among short and medium haul commercial female flight attendants in Indonesia

    Directory of Open Access Journals (Sweden)

    Irma Khrisnapandit

    2016-07-01

    with LBP among short and medium haul commercial female flight attendants in Indonesia. Methods: Cross-sectional study with purposive sampling among short and medium haul commercial female flight attendants who conduct medical examination on May 5-26th 2014 at Civil Aviation Medical Center. Demographic, job and LBP data collected using questionnaire and physical examination. Definition of LBP was historically pain that ever or still felt in lower back in the last month, non-neural, and no non-working related acute injury. Cox regression analysis used to identify risk factor associated LBP. Results: Among 333 female flight attendants who were conducting medical examination, 287 attendants willing to participate, and 240 meet inclusion criteria. There are 37.9% flight attendants experienced LBP. The dominant factors increasing LBP risk were flight time and number of sectors in the last 24 consecutive hours. Female flight attendant with 9 hours or more flight time compared with less have 82% higher LBP risk [adjusted relative risk (RRa = 1.82; p = 0.000]. Review from number of sectors in the last 24 consecutive hours, female flight attendant with 4 sectors or more compared with less have 53% higher LBP risk (RRa = 1.53; p = 0.034.   Conclusion: Nine hours or more flight time and 4 sectors or more in the last 24 consecutive hours have higher risk of LBP Key words: low back pain, female flight attendant, flight time, number of sectors, short and medium haul flight

  4. Study of surfaces and surface layers on high temperature materials after short-time thermal loads

    International Nuclear Information System (INIS)

    Bolt, H.; Hoven, H.; Koizlik, K.; Linke, J.; Nickel, H.; Wallura, E.

    1985-11-01

    Being part of the plasma-wall interaction during TOKAMAK operation, erosion- and redeposition processes of First Wall materials substantially influence plasma parameters as well as the properties of the First Wall. An important redeposition process of eroded material is the formation of thin films by atomic condensation. Examinations of First Wall components after TOKAMAK operation lead to the assumption that these thin metallic films tend to agglomerate to small particles under subsequent heat load. In laboratory experiments it is shown that thin metallic films on various substrates can agglomerate under short time high heat fluxes and also under longer lasting lower thermal loads, thus verifying the ''agglomeration hypothesis''. (orig.) [de

  5. Short-time regularity assessment of fibrillatory waves from the surface ECG in atrial fibrillation

    International Nuclear Information System (INIS)

    Alcaraz, Raúl; Martínez, Arturo; Hornero, Fernando; Rieta, José J

    2012-01-01

    This paper proposes the first non-invasive method for direct and short-time regularity quantification of atrial fibrillatory (f) waves from the surface ECG in atrial fibrillation (AF). Regularity is estimated by computing individual morphological variations among f waves, which are delineated and extracted from the atrial activity (AA) signal, making use of an adaptive signed correlation index. The algorithm was tested on real AF surface recordings in order to discriminate atrial signals with different organization degrees, providing a notably higher global accuracy (90.3%) than the two non-invasive AF organization estimates defined to date: the dominant atrial frequency (70.5%) and sample entropy (76.1%). Furthermore, due to its ability to assess AA regularity wave to wave, the proposed method is also able to pursue AF organization time course more precisely than the aforementioned indices. As a consequence, this work opens a new perspective in the non-invasive analysis of AF, such as the individualized study of each f wave, that could improve the understanding of AF mechanisms and become useful for its clinical treatment. (paper)

  6. Short-Term Forecasting of Urban Storm Water Runoff in Real-Time using Extrapolated Radar Rainfall Data

    DEFF Research Database (Denmark)

    Thorndahl, Søren Liedtke; Rasmussen, Michael R.

    2013-01-01

    Model based short-term forecasting of urban storm water runoff can be applied in realtime control of drainage systems in order to optimize system capacity during rain and minimize combined sewer overflows, improve wastewater treatment or activate alarms if local flooding is impending. A novel onl....... The radar rainfall extrapolation (nowcast) limits the lead time of the system to two hours. In this paper, the model set-up is tested on a small urban catchment for a period of 1.5 years. The 50 largest events are presented....... online system, which forecasts flows and water levels in real-time with inputs from extrapolated radar rainfall data, has been developed. The fully distributed urban drainage model includes auto-calibration using online in-sewer measurements which is seen to improve forecast skills significantly...

  7. Time-separated oscillatory fields for high-precision mass measurements on short-lived Al and Ca nuclides

    CERN Document Server

    George, Simon; Blank, B.; Blaum, K.; Breitenfeldt, M.; Hager, U.; Herfurth, F.; Herlert, A.; Kellerbauer, A.; Kluge, H.J.; Kretzschmar, M.; Lunney, D.; Savreux, R.; Schwarz, Andreas S.; Schweikhard, L.; Yazidjian, C.

    2008-01-01

    High-precision Penning trap mass measurements on the stable nuclide $^{27}$Al as well as on the short-lived radionuclides $^{26}$Al and $^{38,39}$Ca have been performed by use of radio-frequency excitation with time-separated oscillatory fields, i.e. Ramsey's method, as recently introduced for the excitation of the ion motion in a Penning trap, was applied. A comparison with the conventional method of a single continuous excitation demonstrates its advantage of up to ten times shorter measurements. The new mass values of $^{26,27}$Al clarify conflicting data in this specific mass region. In addition, the resulting mass values of the superallowed $\\beta$-emitter $^{38}$Ca as well as of the groundstate of the $\\beta$-emitter $^{26}$Al$^{m}$ confirm previous measurements and corresponding theoretical corrections of the ft-values.

  8. Short-term streamflow forecasting with global climate change implications A comparative study between genetic programming and neural network models

    Science.gov (United States)

    Makkeasorn, A.; Chang, N. B.; Zhou, X.

    2008-05-01

    SummarySustainable water resources management is a critically important priority across the globe. While water scarcity limits the uses of water in many ways, floods may also result in property damages and the loss of life. To more efficiently use the limited amount of water under the changing world or to resourcefully provide adequate time for flood warning, the issues have led us to seek advanced techniques for improving streamflow forecasting on a short-term basis. This study emphasizes the inclusion of sea surface temperature (SST) in addition to the spatio-temporal rainfall distribution via the Next Generation Radar (NEXRAD), meteorological data via local weather stations, and historical stream data via USGS gage stations to collectively forecast discharges in a semi-arid watershed in south Texas. Two types of artificial intelligence models, including genetic programming (GP) and neural network (NN) models, were employed comparatively. Four numerical evaluators were used to evaluate the validity of a suite of forecasting models. Research findings indicate that GP-derived streamflow forecasting models were generally favored in the assessment in which both SST and meteorological data significantly improve the accuracy of forecasting. Among several scenarios, NEXRAD rainfall data were proven its most effectiveness for a 3-day forecast, and SST Gulf-to-Atlantic index shows larger impacts than the SST Gulf-to-Pacific index on the streamflow forecasts. The most forward looking GP-derived models can even perform a 30-day streamflow forecast ahead of time with an r-square of 0.84 and RMS error 5.4 in our study.

  9. Evaluation of jojoba oil as a low-energy fat. 2. Intestinal transit time, stomach emptying and digestibility in short-term feeding studies in rats.

    Science.gov (United States)

    Verschuren, P M; Nugteren, D H

    1989-01-01

    The influence of jojoba oil (JO) incorporation in the diet on stomach emptying and intestinal transit time, and the digestion and absorption of JO were investigated in short-term feeding studies in rats. The animals were fed purified diets containing 18% (w/w) fat, of which half consisted of a mixture of lard and sunflower seed oil (SF) supplemented with an equivalent amount of JO. The control animals were fed a mixture of lard and SF (18%). No treatment-related differences were observed in the rate of stomach emptying or the intestinal transit time. Comparative lipid analysis of lymph, intestinal content, intestinal mucosa and faeces indicated that most of the ingested JO was degraded and absorbed. Part of the JO was present as wax ester in the lymph. Hydrolysis of JO was much slower than that of triacylglycerols and continued in the alimentary tract beyond the small intestine due to bacterial processes. JO did not influence the absorption of the conventional fat.

  10. A Meta-Analysis of the Short- and Long-Term Results of Randomized Controlled Trials That Compared Laparoscopy-Assisted and Conventional Open Surgery for Colorectal Cancer

    Directory of Open Access Journals (Sweden)

    Hiroshi Ohtani, Yutaka Tamamori, Yuichi Arimoto, Yukio Nishiguchi, Kiyoshi Maeda, Kosei Hirakawa

    2011-01-01

    Full Text Available Purpose: We conducted a meta-analysis to evaluate and compare the short- and long-term results of laparoscopic colorectal surgery (LCRS and conventional open surgery (OCRS for colorectal cancer (CRC.Methods: We searched relevant papers published between January 1990 and May 2011. We analyzed the outcomes of each type of surgery over the short- and long-term periods.Results: In the short-term period, we found no significant differences in overall perioperative complications and anastomotic leakage between LCRS and OCRS groups. We found no significant differences in overall, distant, local and wound-site recurrence, overall mortality, 3 and 5 year disease-free survival rate, and cancer-related mortality between the 2 groups.Conclusions: LCRS has the benefits of reducing intraoperative blood loss, earlier resumption of oral intake, and shorter duration of hospital stay in the short-term. The long-term outcomes of LCRS seem to be similar to those of OCRS.

  11. Evaluation of short-term physical weathering of a heavy fuel oil by use of time warping and PCA

    Energy Technology Data Exchange (ETDEWEB)

    Malmquist, L.M.V.; Olsen, R.R. [Roskilde Univ., Roskilde (Denmark). Dept. of Life Sciences and Chemistry]|[National Environmental Research Inst., Roskilde (Denmark). Dept. of Environmental Chemistry and Microbiology; Christensen, J.H. [Royal Veterinary and Agricultural Univ., Thorvaldsensvej (Denmark). Dept. of Natural Sciences; Andersen, O. [Roskilde Univ., Roskilde (Denmark). Dept. of Life Sciences and Chemistry

    2005-07-01

    An estimated 1,140 billion tons of oil was accidentally spilled to the environment during the 1990s. These spills present an ecotoxicologic risk due to the presence of toxic and mutagenic compounds in the oil. Oil is affected by short term and long term weathering processes such as evaporation, dissolution, dispersion, emulsification, photodegradation and biodegradation. Physical weathering processes change the composition of the oil but they do not alter the oil components. Gas chromatography and mass spectrometry can characterize the compositional changes resulting from evaporation. However, the process depends on subjective analysis because it is based on manual interpretation of results and visual inspection. This paper presents a rapid and objective method to compare oil sample compositions. The method is based on automated data preprocessing involving baseline removal, alignment of chromatograms using correlation optimized warping (COW) and normalization. Preprocessed data is analyzed by principal component analysis (PCA) based on the total chromatograms. The method has successfully resolved the effects of evaporation and dissolution processes and showed clear dependence of time, but it did not completely resolve the effect of weathering from the analytical variability because better quality data is required. 21 refs., 3 figs.

  12. Evaluation of short-term physical weathering of a heavy fuel oil by use of time warping and PCA

    International Nuclear Information System (INIS)

    Malmquist, L.M.V.; Olsen, R.R.; Christensen, J.H.; Andersen, O.

    2005-01-01

    An estimated 1,140 billion tons of oil was accidentally spilled to the environment during the 1990s. These spills present an ecotoxicologic risk due to the presence of toxic and mutagenic compounds in the oil. Oil is affected by short term and long term weathering processes such as evaporation, dissolution, dispersion, emulsification, photodegradation and biodegradation. Physical weathering processes change the composition of the oil but they do not alter the oil components. Gas chromatography and mass spectrometry can characterize the compositional changes resulting from evaporation. However, the process depends on subjective analysis because it is based on manual interpretation of results and visual inspection. This paper presents a rapid and objective method to compare oil sample compositions. The method is based on automated data preprocessing involving baseline removal, alignment of chromatograms using correlation optimized warping (COW) and normalization. Preprocessed data is analyzed by principal component analysis (PCA) based on the total chromatograms. The method has successfully resolved the effects of evaporation and dissolution processes and showed clear dependence of time, but it did not completely resolve the effect of weathering from the analytical variability because better quality data is required. 21 refs., 3 figs

  13. High-temperature short-time pasteurisation of human breastmilk is efficient in retaining protein and reducing the bacterial count.

    Science.gov (United States)

    Klotz, Daniel; Joellenbeck, Mirjam; Winkler, Karl; Kunze, Mirjam; Huzly, Daniela; Hentschel, Roland

    2017-05-01

    Milk banks are advised to use Holder pasteurisation to inactivate the cytomegalovirus, but the process adversely affects the bioactive properties of human breastmilk. This study explored the antibacterial efficacy of an alternative high-temperature short-time (HTST) treatment of human breastmilk and its effect on marker proteins, compared with the Holder method. Breastmilk samples were obtained from 27 mothers with infants in a German neonatal intensive care unit. The samples were either heated to 62°C for five seconds using HTST or processed using Holder pasteurisation, at 63 ± 0.5°C for 30 minutes. Immunoglobulin A, lactoferrin, lysozyme, alkaline phosphatase and bile salt-stimulated lipase concentrations and bacterial colony-forming units/mL were measured before and after heating. HTST-treated samples retained higher rates of immunoglobulin A (95% versus 83%), alkaline phosphatase (6% versus 0%) and bile salt-stimulated lipase (0.8% versus 0.4%) than Holder pasteurisation samples (all p HTST treatment protocol retained some of the bioactive properties of human breastmilk and appeared to have similar antibacterial efficacy to Holder pasteurisation. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  14. Testing of Commercial Milk Production Technology Using A Combination of High Temperature Short Time and Pulsed Electric Field

    OpenAIRE

    Hadi A; Widjanarko SB; Kusnadi J

    2016-01-01

    The development of milk processing technology has grown excessively, and it contains advantage and disadvantage. This study used mixed between PEF (Pulsed Electric Field) and High Temperature Short Time (HTST) to produce milk processed product which is effective and efficient in killing milk microorganism without changing its color, scent, and nutrient content of processed product, therefore producing commercial sterile milk product in accord with milk Indonesian National Standard (SNI). The ...

  15. Internet-Related Disorders: Development of the Short Compulsive Internet Use Scale.

    Science.gov (United States)

    Besser, Bettina; Rumpf, Hans-Jürgen; Bischof, Anja; Meerkerk, Gert-Jan; Higuchi, Susumu; Bischof, Gallus

    2017-11-01

    The addiction treatment system only reaches a small number of individuals suffering from Internet-related disorders. Therefore, it is important to improve case detection for preventive measures and brief interventions. Existing screening instruments are often time-consuming and rarely validated using clinical criteria. The aim of this study is to develop an optimized short screening for problematic Internet use and Internet addiction (IA). A regression analysis was conducted in random subsamples of a merged sample (N = 3,040; N = 1,209) to examine the item performance of the Compulsive Internet Use Scale (CIUS). Based on the results, a short version of the CIUS was developed and compared with the original CIUS. A fully structured diagnostic interview, covering the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) criteria for the Internet gaming disorder with a broader focus on all Internet activities, was conducted. A five-item version of the short screening performed best across the samples. Comparing the area under the curve (AUC) of the receiver operating characteristic between the Short CIUS and the original test revealed no significant difference (AUC = 0.968; 0.977). A cutoff point of 7 turned out to perform best for case detection and yielded a sensitivity of 0.95 and a specificity of 0.87, Cronbach's alpha was 0.77. The analysis showed that the performance of the Short CIUS is just as good in detecting problematical Internet use and IA as the performance of the original CIUS. The Short CIUS provides an economical and valid instrument for the assessment of problematic Internet use and IA.

  16. Performance Analysis of the Enhanced DSR Routing Protocol for the Short Time Disconnected MANET to the OPNET Modeler

    Directory of Open Access Journals (Sweden)

    PAPAJ Ján

    2013-05-01

    Full Text Available Disconnected mobile ad-hoc networks (MANET are very important areas of the research. In this article, the performance analysis of the enhanced dynamic source routing protocol (OPP_DSR is introduced. This modification enables the routing process in the case when there are no connections to other mobile nodes. It also will enable the routing mechanisms when the routes, selected by routing mechanisms, are disconnected for some time. Disconnection can be for a short time and standard routing protocol DSR cannot reflect on this situation.The main idea is based on opportunistic forwarding where the nodes not only forward data but it's stored in the cache during long time. The network parameters throughput, routing load and are analysed.

  17. Comparing older and younger Japanese primiparae: fatigue, depression and biomarkers of stress.

    Science.gov (United States)

    Mori, Emi; Maehara, Kunie; Iwata, Hiroko; Sakajo, Akiko; Tsuchiya, Miyako; Ozawa, Harumi; Morita, Akiko; Maekawa, Tomoko; Saeki, Akiko

    2015-03-01

    This cohort study of primiparae was conducted to answer the following questions: Do older (≧ 35 years) and younger (20-29 years) Japanese primiparous mothers differ when comparing biomarkers of stress and measures of fatigue and depression? Are there changes in fatigue, depression and stress biomarkers when comparing older and younger mothers during the postpartum period? The Postnatal Accumulated Fatigue Scale and the Edinburgh Postnatal Depression Scale were administered in a time-series method four times: shortly after birth and monthly afterwards. Assays to measure biomarkers of stress, urinary 17-ketosteroids, urinary 17-hydroxycorticosteroids and salivary chromogranin-A, were collected shortly after delivery and at 1 month postpartum in both groups and a third time in older mothers at the 4th month. Statistical testing showed very little difference in fatigue, depression or stress biomarkers between older and younger mothers shortly after birth or 1 month later. Accumulated fatigue and depression scores of older mothers were highest 1 month after delivery. Additional cohort studies are required to characterize physical/psychological well-being of older Japanese primiparae. © 2015 Wiley Publishing Asia Pty Ltd.

  18. Comparative evaluation of the effectiveness of the implantation in the lateral part of the mandible between short tissue level (TE) and bone level (BL) implant systems.

    Science.gov (United States)

    Hadzik, Jakub; Botzenhart, Ute; Krawiec, Maciej; Gedrange, Tomasz; Heinemann, Friedhelm; Vegh, Andras; Dominiak, Marzena

    2017-09-01

    Short dental implants can be an alternative method of treatment to a vertical bone augmentation procedure at sites of reduced alveolar height. However, for successful treatment, an implant system that causes a minimal marginal bone loss (MBL) should be taken into consideration. The aim of the study has been to evaluate implantation effectiveness for bone level and tissue level short implants provided in lateral aspects of partially edentulous mandible and limited alveolar ridge height. The MBL and primary as well as secondary implant stability were determined in the study. Patients were randomly divided into two groups according to the method of treatment provided. Sixteen short Bone Level Implants (OsseoSpeed TX, Astra tech) and 16 short Tissue Level Implants (RN SLActive ® , Straumann) were successfully placed in the edentulous part of the mandible. The determination of the marginal bone level was based on radiographic evaluation after 12 and 36 weeks. Implant stability was measured immediately after insertion and after 12 weeks. The marginal bone level of Bone Level Implants was significantly lower compared to Tissue Level Implants. Furthermore, the Bone Level Implants had greater primary and secondary stability in comparison with Tissue Level Implants (Primary: 77.8 ISQ versus 66.5 ISQ; Secondary: 78.9 ISQ versus 73.9 ISQ, respectively). Since short Bone Level Implants showed a significantly decreased MBL 12 and 36 weeks after implantation as well as better results for the primary stability compared to Tissue Level Implants, they should preferentially be used for this mentioned indication. Copyright © 2017 Elsevier GmbH. All rights reserved.

  19. Mechanistic models for cancer development after short time radiation exposure

    International Nuclear Information System (INIS)

    Kottbauer, M. M.

    1997-12-01

    In this work two biological based models were developed. First the single-hit model for solid tumors (SHM-S) and second the single-hit model for leukemia (SHM-L). These models are a further development of the Armitage-Doll model for the special case of a short time radiation exposure. The basis of the models is the multistage process of carcinogeneses. The single-hit models provide simultaneously the age-dependent cancer-rate of spontaneous and radiation induced tumors as well as the dose-effect relationships at any age after exposure. The SHM-S leads to a biological based dose-effect relationship, which is similar to the relative risk model suggested by the ICRP 60. The SHM-S describes the increased mortality rate of the bomb survivors more accurate than the relative risk model. The SHM-L results in an additive dose-effect relationship. It is shown that only small differences in the derivation of the two models lead to the two dose-effect relationships. Beside the radiation exposure the new models consider the decrease of the cancer mortality rate at higher ages (age>75) which can be traced back mainly to three causes: competitive causes of death, reduction of cell proliferation and reduction of risk groups. The single-hit models also consider children cancer, the different rates of incidence and mortality, influence of the immune system and the cell-killing effect. (author)

  20. Auditory short-term memory behaves like visual short-term memory.

    Directory of Open Access Journals (Sweden)

    Kristina M Visscher

    2007-03-01

    Full Text Available Are the information processing steps that support short-term sensory memory common to all the senses? Systematic, psychophysical comparison requires identical experimental paradigms and comparable stimuli, which can be challenging to obtain across modalities. Participants performed a recognition memory task with auditory and visual stimuli that were comparable in complexity and in their neural representations at early stages of cortical processing. The visual stimuli were static and moving Gaussian-windowed, oriented, sinusoidal gratings (Gabor patches; the auditory stimuli were broadband sounds whose frequency content varied sinusoidally over time (moving ripples. Parallel effects on recognition memory were seen for number of items to be remembered, retention interval, and serial position. Further, regardless of modality, predicting an item's recognizability requires taking account of (1 the probe's similarity to the remembered list items (summed similarity, and (2 the similarity between the items in memory (inter-item homogeneity. A model incorporating both these factors gives a good fit to recognition memory data for auditory as well as visual stimuli. In addition, we present the first demonstration of the orthogonality of summed similarity and inter-item homogeneity effects. These data imply that auditory and visual representations undergo very similar transformations while they are encoded and retrieved from memory.

  1. Auditory short-term memory behaves like visual short-term memory.

    Science.gov (United States)

    Visscher, Kristina M; Kaplan, Elina; Kahana, Michael J; Sekuler, Robert

    2007-03-01

    Are the information processing steps that support short-term sensory memory common to all the senses? Systematic, psychophysical comparison requires identical experimental paradigms and comparable stimuli, which can be challenging to obtain across modalities. Participants performed a recognition memory task with auditory and visual stimuli that were comparable in complexity and in their neural representations at early stages of cortical processing. The visual stimuli were static and moving Gaussian-windowed, oriented, sinusoidal gratings (Gabor patches); the auditory stimuli were broadband sounds whose frequency content varied sinusoidally over time (moving ripples). Parallel effects on recognition memory were seen for number of items to be remembered, retention interval, and serial position. Further, regardless of modality, predicting an item's recognizability requires taking account of (1) the probe's similarity to the remembered list items (summed similarity), and (2) the similarity between the items in memory (inter-item homogeneity). A model incorporating both these factors gives a good fit to recognition memory data for auditory as well as visual stimuli. In addition, we present the first demonstration of the orthogonality of summed similarity and inter-item homogeneity effects. These data imply that auditory and visual representations undergo very similar transformations while they are encoded and retrieved from memory.

  2. Short-term azithromycin treatment promotes cornea allograft survival in the rat.

    Science.gov (United States)

    Wacker, Katrin; Denker, Sophy; Hildebrand, Antonia; Eberwein, Philipp; Reinhard, Thomas; Schwartzkopff, Johannes

    2013-01-01

    Any inflammatory response following corneal transplantation may induce rejection and irreversible graft failure. The purpose of this study is to analyze the anti-inflammatory effect of azithromycin (AZM) following experimental keratoplasty in rats. Corneal transplants were performed between Fisher-donor and Lewis-recipient rats. Recipients were postoperatively treated three times daily with AZM, miglyol, ofloxacin or dexamethasone eye drops. As an additional control, AZM was applied following syngeneic keratoplasty. Furthermore, short-term treatments with AZM for seven days perioperatively or with AZM only three days prior to the transplantation were compared to appropriate controls. All transplants were monitored clinically for opacity, edema, and vascularization. Infiltrating CD45(+), CD4(+), CD8(+), CD25(+), CD161(+) and CD163(+) cells were quantified via immunohistochemistry. AZM significantly promoted corneal graft survival compared with miglyol or ofloxacin treatment. This effect was comparable to topical dexamethasone. No adverse AZM effect was observed. Histology confirmed a significant reduction of infiltrating leukocytes. The short-term application of AZM for three days prior to transplantation or for seven days perioperatively reduced corneal graft rejection significantly compared with the controls. Along with antibiotic properties, topical AZM has a strong anti-inflammatory effect. Following keratoplasty, this effect is comparable to topical dexamethasone without the risk of steroid-induced adverse effects. Short-term treatment with AZM three days prior to the transplantation was sufficient to promote graft survival in the rat keratoplasty model. We therefore suggest further assessing the anti-inflammatory function of topical AZM following keratoplasty in humans.

  3. Short-term azithromycin treatment promotes cornea allograft survival in the rat.

    Directory of Open Access Journals (Sweden)

    Katrin Wacker

    Full Text Available Any inflammatory response following corneal transplantation may induce rejection and irreversible graft failure. The purpose of this study is to analyze the anti-inflammatory effect of azithromycin (AZM following experimental keratoplasty in rats.Corneal transplants were performed between Fisher-donor and Lewis-recipient rats. Recipients were postoperatively treated three times daily with AZM, miglyol, ofloxacin or dexamethasone eye drops. As an additional control, AZM was applied following syngeneic keratoplasty. Furthermore, short-term treatments with AZM for seven days perioperatively or with AZM only three days prior to the transplantation were compared to appropriate controls. All transplants were monitored clinically for opacity, edema, and vascularization. Infiltrating CD45(+, CD4(+, CD8(+, CD25(+, CD161(+ and CD163(+ cells were quantified via immunohistochemistry.AZM significantly promoted corneal graft survival compared with miglyol or ofloxacin treatment. This effect was comparable to topical dexamethasone. No adverse AZM effect was observed. Histology confirmed a significant reduction of infiltrating leukocytes. The short-term application of AZM for three days prior to transplantation or for seven days perioperatively reduced corneal graft rejection significantly compared with the controls.Along with antibiotic properties, topical AZM has a strong anti-inflammatory effect. Following keratoplasty, this effect is comparable to topical dexamethasone without the risk of steroid-induced adverse effects. Short-term treatment with AZM three days prior to the transplantation was sufficient to promote graft survival in the rat keratoplasty model. We therefore suggest further assessing the anti-inflammatory function of topical AZM following keratoplasty in humans.

  4. Leadership emergence over time in short-lived groups: Integrating expectations states theory with temporal person-perception and self-serving bias.

    Science.gov (United States)

    Kalish, Yuval; Luria, Gil

    2016-10-01

    Research into leadership emergence typically focuses on the attributes of the emergent leader. By considering also the attributes of perceivers and the passage of time, we develop a more complete theory of leadership emergence in short-lived groups. Using expectation states theory as an overarching theoretical framework, and integrating it with the surface- and deep-level diversity literature and with theories of self-serving biases, we examine the predictors of leadership emergence in short timeframes. We conduct a field study in a military assessment boot camp (a pilot study, n = 60; and a main study, n = 89). We use cross-sectional and longitudinal exponential random graph models to analyze data on participants' abilities and on their perceptions of who, in their respective groups, were "leaders." We find that the criteria by which people perceive leadership in others change over time, from easily noticeable attributes to covert leadership-relevant attributes, and that people also rely on leadership-relevant attributes that they possess at high levels to inform their perceptions of leadership in others. The integration of expectation states theory, attribute salience over time and theories of self-serving bias is needed for a full understanding of leadership emergence in groups, because perceivers' own abilities are instrumental in shaping their perceptions of emergent leadership over time. Theoretical and practical implications are discussed. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  5. Conditions of the existence of 'short circuit' effect for plasma in a conducting cylinder

    International Nuclear Information System (INIS)

    Zhilinskij, A.P.; Kuteev, B.V.

    1975-01-01

    It has been experimentally established that in a cylindrical container with conducting side and end walls, the phenomenon of short circuit (the Symon effect) is not always realized. The short circuiting of plane end and of side surfaces causes an acceleration of a plasma decay only during the initial stage in a comparatively short time. Characteristic lifetimes during the late stage remain unchanged in this case. In conditions of a stable plasma they correspond to classical values of the plasma decay constant at the ambipolar diffusion of charged particles along and across force lines of a magnetic field. A fundamental change in the nature of the diffusion and a decrease of the plasma lifetime almost by two orders are realized in an instrument in which an end conducting wall for plasma in created with a short cylinder at the end of a solenoid in a sharply nonuniform magnetic field. The data obtained testify to the fact that the short circuit effect takes place in conditions when on boundaries of plasma the possibility of simultaneous flowing of unipolar electron flows along and of ion flows across a magnetic field is assured. The results of the experiments are compared with a theory

  6. Distribution of Short-Term and Lifetime Predicted Risks of Cardiovascular Diseases in Peruvian Adults.

    Science.gov (United States)

    Quispe, Renato; Bazo-Alvarez, Juan Carlos; Burroughs Peña, Melissa S; Poterico, Julio A; Gilman, Robert H; Checkley, William; Bernabé-Ortiz, Antonio; Huffman, Mark D; Miranda, J Jaime

    2015-08-07

    Short-term risk assessment tools for prediction of cardiovascular disease events are widely recommended in clinical practice and are used largely for single time-point estimations; however, persons with low predicted short-term risk may have higher risks across longer time horizons. We estimated short-term and lifetime cardiovascular disease risk in a pooled population from 2 studies of Peruvian populations. Short-term risk was estimated using the atherosclerotic cardiovascular disease Pooled Cohort Risk Equations. Lifetime risk was evaluated using the algorithm derived from the Framingham Heart Study cohort. Using previously published thresholds, participants were classified into 3 categories: low short-term and low lifetime risk, low short-term and high lifetime risk, and high short-term predicted risk. We also compared the distribution of these risk profiles across educational level, wealth index, and place of residence. We included 2844 participants (50% men, mean age 55.9 years [SD 10.2 years]) in the analysis. Approximately 1 of every 3 participants (34% [95% CI 33 to 36]) had a high short-term estimated cardiovascular disease risk. Among those with a low short-term predicted risk, more than half (54% [95% CI 52 to 56]) had a high lifetime predicted risk. Short-term and lifetime predicted risks were higher for participants with lower versus higher wealth indexes and educational levels and for those living in urban versus rural areas (PPeruvian adults were classified as low short-term risk but high lifetime risk. Vulnerable adults, such as those from low socioeconomic status and those living in urban areas, may need greater attention regarding cardiovascular preventive strategies. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  7. Cardiovascular health profile of elite female football players compared to untrained controls before and after short-term football training

    DEFF Research Database (Denmark)

    Randers, Morten Bredsgaard; Andersen, Lars Juel; Ørntoft, Christina Øyangen

    2013-01-01

    Abstract This study examined the intermittent exercise performance and cardiovascular health profile in elite female football players in comparison to untrained young women, as well as a subgroup subjected to football training 2x1 h · week(-1) for 16 weeks. Twenty-seven Danish national team players...... weeks of football training with 26 and 46% increases in TAPSE and E/A ratio, respectively, reaching levels comparable to ET. In summary, elite female football players have a superior cardiovascular health profile and intermittent exercise performance compared to untrained controls, but short...... (elite trained, ET) and 28 untrained women (UT) underwent dual-energy X-ray absorptiometry-scanning (DXA), comprehensive transthoracic echocardiography, treadmill and Yo-Yo Intermittent Endurance level 2 (IE2) testing. Eight women in UT were also tested after the football training period. Maximal oxygen...

  8. Examining the short-run price elasticity of gasoline demand in the United States

    Science.gov (United States)

    Brannan, Michael James

    Estimating the consumer demand response to changes in the price of gasoline has important implications regarding fuel tax policies and environmental concerns. There are reasons to believe that the short-run price elasticity of gasoline demand fluctuates due to changing structural and behavioral factors. In this paper I estimate the short-run price elasticity of gasoline demand in two time periods, from 2001 to 2006 and from 2007 to 2010. This study utilizes data at both the national and state levels to produce estimates. The short-run price elasticities range from -0.034 to -0.047 during 2001 to 2006, compared to -0.058 to -0.077 in the 2007 to 2010 period. This paper also examines whether there are regional differences in the short-run price elasticity of gasoline demand in the United States. However, there appears to only be modest variation in price elasticity values across regions.

  9. Short-term scheduling of an open-pit mine with multiple objectives

    Science.gov (United States)

    Blom, Michelle; Pearce, Adrian R.; Stuckey, Peter J.

    2017-05-01

    This article presents a novel algorithm for the generation of multiple short-term production schedules for an open-pit mine, in which several objectives, of varying priority, characterize the quality of each solution. A short-term schedule selects regions of a mine site, known as 'blocks', to be extracted in each week of a planning horizon (typically spanning 13 weeks). Existing tools for constructing these schedules use greedy heuristics, with little optimization. To construct a single schedule in which infrastructure is sufficiently utilized, with production grades consistently close to a desired target, a planner must often run these heuristics many times, adjusting parameters after each iteration. A planner's intuition and experience can evaluate the relative quality and mineability of different schedules in a way that is difficult to automate. Of interest to a short-term planner is the generation of multiple schedules, extracting available ore and waste in varying sequences, which can then be manually compared. This article presents a tool in which multiple, diverse, short-term schedules are constructed, meeting a range of common objectives without the need for iterative parameter adjustment.

  10. Parental leave: comparing children's hospitals with Fortune 500 companies.

    Science.gov (United States)

    Weiss, A H; Gordon, E J; O'Connor, M E

    1998-07-01

    To identify parental leave policies and availability of support systems for new parents employed by children's hospitals and compare these benefits with those offered by Fortune 500 companies. Telephone or facsimile survey of all (n=118) children's hospitals and pediatric medical centers in the National Association of Children's Hospitals and Related Institutions 1995 Directory of Members, and 118 geographically matched Fortune 500 companies. Policies for maternity and paternity leave, adoption benefits, and support services for new parents were compared. Ninety-four children's hospitals (80%) and 82 Fortune 500 companies (69%) responded to the survey. No difference in duration of maternity (P>.30) or paternity (P=.12) leave was found. Sixty-two companies (77%) classified maternity leave as short-term disability while 47 hospitals (50%) classified it as sick time (Pleave as short-term disability generally gives better benefits to employees with short duration of service, whereas classifying maternity leave as sick time usually favors employees with longer employment. Companies provided more financial support for adoption expenses (Ppaid or unpaid leave for adoption (P=.14). Hospitals provided more on-site day care (69% vs 42%; Pparental leave benefits than Fortune 500 companies; however, they offer better support systems for parents returning to work after the birth of a child.

  11. Short term protein supplementation during a long interval prostaglandin-based protocol for timed AI in sheep.

    Science.gov (United States)

    Errandonea, N; Fierro, S; Viñoles, C; Gil, J; Banchero, G; Olivera-Muzante, J

    2018-03-21

    .5%), and fertility rate (63.3 vs. 61.5%; P < 0.05) remained similar in PG15 supplemented or not supplemented ewes. In conclusion, a short-term protein supplementation before cervical time artificial insemination improved the reproductive performance of ewes synchronized with the PG15 protocol to levels comparable to the SE group. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Overview, comparative assessment and recommendations of forecasting models for short-term water demand prediction

    CSIR Research Space (South Africa)

    Anele, AO

    2017-11-01

    Full Text Available -term water demand (STWD) forecasts. In view of this, an overview of forecasting methods for STWD prediction is presented. Based on that, a comparative assessment of the performance of alternative forecasting models from the different methods is studied. Times...

  13. Comparative analysis of clustering methods for gene expression time course data

    Directory of Open Access Journals (Sweden)

    Ivan G. Costa

    2004-01-01

    Full Text Available This work performs a data driven comparative study of clustering methods used in the analysis of gene expression time courses (or time series. Five clustering methods found in the literature of gene expression analysis are compared: agglomerative hierarchical clustering, CLICK, dynamical clustering, k-means and self-organizing maps. In order to evaluate the methods, a k-fold cross-validation procedure adapted to unsupervised methods is applied. The accuracy of the results is assessed by the comparison of the partitions obtained in these experiments with gene annotation, such as protein function and series classification.

  14. A comparative study of the effectiveness of early and delayed loading of short tissue-level dental implants with hydrophilic surfaces placed in the posterior section of the mandible-A preliminary study.

    Science.gov (United States)

    Makowiecki, Arkadiusz; Botzenhart, Ute; Seeliger, Julia; Heinemann, Friedhelm; Biocev, Peter; Dominiak, Marzena

    2017-07-01

    The objective of the present study was to compare the primary and secondary stability of tissue-level short dental titanium implants with polished necks and hydrophilic surfaces of two different designs and manufacturers. The first implant system used (SPI ® ELEMENT RC INICELL titanium implants, Thommen Medical AG, Grenchen, Switzerland), allowed functional loading 6 weeks after its placement, whereas the second implant system (RN SLActiv ® tissue-level titanium implants, Straumann GmbH, Fribourg, Germany), was loaded after 15 weeks. The degree of primary and secondary stability was determined using an Osstell ISQ measuring device. Marginal bone loss (MBL) was evaluated radiographically 12 and 24 weeks after implantation and the Wachtel's healing index as well as the patient's satisfaction with the treatment was registered on a VAS scale. The intergroup comparison revealed significant differences in terms of primary stability as well as differences in MBL 3 months after the procedure, but no significant differences could be found after 6 months and for secondary stability. The primary stability was significantly higher for Thommen ® compared to Straumann ® implants. Insertion of short dental implants with a hydrophilic conditioned surface significantly shortens patient treatment time. Copyright © 2017 Elsevier GmbH. All rights reserved.

  15. Mapping rice-fallow cropland areas for short-season grain legumes intensification in South Asia using MODIS 250 m time-series data

    Science.gov (United States)

    Gumma, Murali Krishna; Thenkabail, Prasad S.; Teluguntla, Pardhasaradhi G.; Rao, Mahesh N.; Mohammed, Irshad A.; Whitbread, Anthony M.

    2016-01-01

    study established cropland classes based on the every 16-day 250 m normalized difference vegetation index (NDVI) time series for one year (June 2010–May 2011) of Moderate Resolution Imaging Spectroradiometer (MODIS) data, using spectral matching techniques (SMTs), and extensive field knowledge. Map accuracy was evaluated based on independent ground survey data as well as compared with available sub-national level statistics. The producers’ and users’ accuracies of the cropland fallow classes were between 75% and 82%. The overall accuracy and the kappa coefficient estimated for rice classes were 82% and 0.79, respectively. The analysis estimated approximately 22.3 Mha of suitable rice-fallow areas in South Asia, with 88.3% in India, 0.5% in Pakistan, 1.1% in Sri Lanka, 8.7% in Bangladesh, 1.4% in Nepal, and 0.02% in Bhutan. Decision-makers can target these areas for sustainable intensification of short-duration grain legumes.

  16. 26 CFR 1.6655-5 - Short taxable year.

    Science.gov (United States)

    2010-04-01

    ... Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Additions to the Tax, Additional Amounts, and Assessable Penalties § 1.6655-5 Short taxable... beginning with its initial short taxable year to the time it files its tax return for its initial short...

  17. [Effect of short-time drought process on denitrifying bacteria abundance and N2O emission in paddy soil].

    Science.gov (United States)

    Lu, Jing; Liu, Jin-Bo; Sheng, Rong; Liu, Yi; Chen, An-Lei; Wei, Wen-Xue

    2014-10-01

    In order to investigate the impact of drying process on greenhouse gas emissions and denitrifying microorganisms in paddy soil, wetting-drying process was simulated in laboratory conditions. N2O flux, redox potential (Eh) were monitored and narG- and nosZ-containing denitrifiers abundances were determined by real-time PCR. N2O emission was significantly increased only 4 h after drying process began, and it was more than 6 times of continuous flooding (CF) at 24 h. In addition, narG and nosZ gene abundances were increased rapidly with the drying process, and N2O emission flux was significantly correlated with narG gene abundance (P driving microorganisms which caused the N2O emission in the short-time drought process in paddy soil.

  18. Preparatory Body State before Reacting to an Opponent: Short-Term Joint Torque Fluctuation in Real-Time Competitive Sports.

    Science.gov (United States)

    Fujii, Keisuke; Yamashita, Daichi; Kimura, Tetsuya; Isaka, Tadao; Kouzaki, Motoki

    2015-01-01

    In a competitive sport, the outcome of a game is determined by an athlete's relationship with an unpredictable and uncontrolled opponent. We have previously analyzed the preparatory state of ground reaction forces (GRFs) dividing non-weighted and weighted states (i.e., vertical GRFs below and above 120% of body weight, respectively) in a competitive ballgame task and demonstrated that the non-weighted state prevented delay of the defensive step and promoted successful guarding. However, the associated kinetics of lower extremity joints during a competitive sports task remains unknown. The present study aims to investigate the kinetic characteristics of a real-time competitive sport before movement initiation. As a first kinetic study on a competitive sport, we initially compared the successful defensive kinetics with a relatively stable preparatory state and the choice-reaction sidestep as a control movement. Then, we investigated the kinetic cause of the outcome in a 1-on-1 dribble in terms of the preparatory states according to our previous study. The results demonstrated that in successful defensive motions in the non-weighted state guarding trial, the times required for the generation of hip abduction and three extension torques for the hip, knee, and ankle joints were significantly shortened compared with the choice-reaction sidestep, and hip abduction and hip extension torques were produced almost simultaneously. The sport-specific movement kinetics emerges only in a more-realistic interactive experimental setting. A comparison of the outcomes in the 1-on-1 dribble and preparatory GRF states showed that, in the non-weighted state, the defenders guarded successfully in 68.0% of the trials, and the defender's initiation time was earlier than that in the weighted state (39.1%). In terms of kinetics, the root mean squares of the derivative of hip abduction and three extension torques in the non-weighted state were smaller than those in the weighted state

  19. Pain score of patients undergoing single spot, short pulse laser versus conventional laser for diabetic retinopathy.

    Science.gov (United States)

    Mirshahi, Ahmad; Lashay, Alireza; Roozbahani, Mehdi; Fard, Masoud Aghsaei; Molaie, Saber; Mireshghi, Meysam; Zaferani, Mohamad Mehdi

    2013-04-01

    To compare pain score of single spot short duration time (20 milliseconds) panretinal photocoagulation (PRP) with conventional (100 milliseconds) PRP in diabetic retinopathy. Sixty-six eyes from 33 patients with symmetrical severe non-proliferative diabetic retinopathy (non-PDR) or proliferative diabetic retinopathy (PDR) were enrolled in this prospective randomized controlled trial. One eye of each patient was randomized to undergo conventional and the other eye to undergo short time PRP. Spot size of 200 μm was used in both laser types, and energy was adjusted to achieve moderate burn on the retina. Patients were asked to mark the level of pain felt during the PRP session for each eye on the visual analog scale (VAS) and were examined at 1 week, and at 1, 2, 4 and 6 months. Sixteen women and 17 men with mean age 58.9 ± 7.8 years were evaluated. The conventional method required a mean power of 273 ± 107 mW, whereas the short duration method needed 721 ± 406 mW (P = 0.001). An average of 1,218 ± 441 spots were delivered with the conventional method and an average of 2,125 ± 503 spots were required with the short duration method (P = 0.001). Average pain score was 7.5 ± 1.14 in conventional group and 1.75 ± 0.87 in the short duration group (P = 0.001). At 1 week, 1 month, and 4 months following PRP, the mean changes of central macular thickness (CMT) from baseline in the conventional group remained 29.2 μm (P = 0.008), 40.0 μm (P = 0.001), and 40.2 μm (P = 0.007) greater than the changes in CMT for short time group. Patient acceptance of short time single spot PRP was high, and well-tolerated in a single session by all patients. Moreover, this method is significantly less painful than but just as effective as conventional laser during 6 months of follow-up. The CMT change was more following conventional laser than short time laser.

  20. Does Occupational Exposure of Shahid Dastghieb International Airport Workers to Radiofrequency Radiation Affect Their Short Term Memory and Reaction Time?

    Directory of Open Access Journals (Sweden)

    Jarideh S.

    2015-05-01

    Full Text Available Background: Airport workers are continuously exposed to different levels of radiofrequency microwave (RF/MW radiation emitted by radar equipments. Radars are extensively used in military and aviation industries. Over the past several years, our lab has focused on the health effects of exposure to different sources of electromagnetic fields such as cellular phones, mobile base stations, mobile phone jammers, laptop computers, radars, dentistry cavitrons and MRI. The main goal of this study was to investigate if occupational exposure of Shahid Dastghieb international airport workers to radiofrequency radiation affects their short term memory and reaction time. Methods: Thirty two airport workers involved in duties at control and approach tower (21 males and 11 females, with the age range of 27-67 years old (mean age of 37.38, participated voluntary in this study. On the other hand, 29 workers (13 males, and 16 females whose offices were in the city with no exposure history to radar systems were also participated in this study as the control group. The employees’ reaction time and short term memory were analyzed using a standard visual reaction time (VRT test software and the modified Wechsler memory scale test, respectively. Results: The mean± SD values for the reaction times of the airport employees (N=32 and the control group (N=29 were 0.45±0.12 sec and 0.46±0.17 sec, respectively. Moreover, in the four subset tests; i.e. paired words, forward digit span, backward digit span and word recognition, the following points were obtained for the airport employees and the control group, respectively: (i pair words test: 28.00±13.13 and 32.07±11.65, (ii forward digit span: 8.38±1.40 and 9.03±1.32, (iii backward digit span: 5.54±1.87 and 6.31±1.46, and (iv word recognition: 5.73±2.36 and 6.50±1.93. These differences were not statistically significant. Conclusion: The occupational exposure of the employees to the RF radiation in Shahid

  1. Pedestrian Path Prediction with Recursive Bayesian Filters: A Comparative Study

    NARCIS (Netherlands)

    Schneider, N.; Gavrila, D.M.

    2013-01-01

    In the context of intelligent vehicles, we perform a comparative study on recursive Bayesian filters for pedestrian path prediction at short time horizons (< 2s). We consider Extended Kalman Filters (EKF) based on single dynamical models and Interacting Multiple Models (IMM) combining several such

  2. Impact of Spatial and Verbal Short-Term Memory Load on Auditory Spatial Attention Gradients.

    Science.gov (United States)

    Golob, Edward J; Winston, Jenna; Mock, Jeffrey R

    2017-01-01

    Short-term memory load can impair attentional control, but prior work shows that the extent of the effect ranges from being very general to very specific. One factor for the mixed results may be reliance on point estimates of memory load effects on attention. Here we used auditory attention gradients as an analog measure to map-out the impact of short-term memory load over space. Verbal or spatial information was maintained during an auditory spatial attention task and compared to no-load. Stimuli were presented from five virtual locations in the frontal azimuth plane, and subjects focused on the midline. Reaction times progressively increased for lateral stimuli, indicating an attention gradient. Spatial load further slowed responses at lateral locations, particularly in the left hemispace, but had little effect at midline. Verbal memory load had no (Experiment 1), or a minimal (Experiment 2) influence on reaction times. Spatial and verbal load increased switch costs between memory encoding and attention tasks relative to the no load condition. The findings show that short-term memory influences the distribution of auditory attention over space; and that the specific pattern depends on the type of information in short-term memory.

  3. Impact of Spatial and Verbal Short-Term Memory Load on Auditory Spatial Attention Gradients

    Directory of Open Access Journals (Sweden)

    Edward J. Golob

    2017-11-01

    Full Text Available Short-term memory load can impair attentional control, but prior work shows that the extent of the effect ranges from being very general to very specific. One factor for the mixed results may be reliance on point estimates of memory load effects on attention. Here we used auditory attention gradients as an analog measure to map-out the impact of short-term memory load over space. Verbal or spatial information was maintained during an auditory spatial attention task and compared to no-load. Stimuli were presented from five virtual locations in the frontal azimuth plane, and subjects focused on the midline. Reaction times progressively increased for lateral stimuli, indicating an attention gradient. Spatial load further slowed responses at lateral locations, particularly in the left hemispace, but had little effect at midline. Verbal memory load had no (Experiment 1, or a minimal (Experiment 2 influence on reaction times. Spatial and verbal load increased switch costs between memory encoding and attention tasks relative to the no load condition. The findings show that short-term memory influences the distribution of auditory attention over space; and that the specific pattern depends on the type of information in short-term memory.

  4. A deep learning framework for financial time series using stacked autoencoders and long-short term memory.

    Science.gov (United States)

    Bao, Wei; Yue, Jun; Rao, Yulei

    2017-01-01

    The application of deep learning approaches to finance has received a great deal of attention from both investors and researchers. This study presents a novel deep learning framework where wavelet transforms (WT), stacked autoencoders (SAEs) and long-short term memory (LSTM) are combined for stock price forecasting. The SAEs for hierarchically extracted deep features is introduced into stock price forecasting for the first time. The deep learning framework comprises three stages. First, the stock price time series is decomposed by WT to eliminate noise. Second, SAEs is applied to generate deep high-level features for predicting the stock price. Third, high-level denoising features are fed into LSTM to forecast the next day's closing price. Six market indices and their corresponding index futures are chosen to examine the performance of the proposed model. Results show that the proposed model outperforms other similar models in both predictive accuracy and profitability performance.

  5. The Short-Time Behaviour of VIX Implied Volatilities in a Multifactor Stochastic Volatility Framework

    DEFF Research Database (Denmark)

    Barletta, Andrea; Nicolato, Elisa; Pagliarani, Stefano

    error bounds for VIX futures, options and implied volatilities. In particular, we derive exact asymptotic results for VIX implied volatilities, and their sensitivities, in the joint limit of short time-to-maturity and small log-moneyness. The obtained expansions are explicit, based on elementary...... approximations of equity (SPX) options. However, the generalizations needed to cover the case of VIX options are by no means straightforward as the dynamics of the underlying VIX futures are not explicitly known. To illustrate the accuracy of our technique, we provide numerical implementations for a selection...... functions and they neatly uncover how the VIX skew depends on the specific choice of the volatility and the vol-of-vol processes. Our results are based on perturbation techniques applied to the infinitesimal generator of the underlying process. This methodology has been previously adopted to derive...

  6. Biological effect of pulsed dose rate brachytherapy with stepping sources if short half-times of repair are present in tissues

    International Nuclear Information System (INIS)

    Fowler, Jack F.; Limbergen, Erik F.M. van

    1997-01-01

    Purpose: To explore the possible increase of radiation effect in tissues irradiated by pulsed brachytherapy (PDR) for local tissue dose rates between those 'averaged over the whole pulse' and the instantaneous high dose rates close to the dwell positions. Increased effect is more likely for tissues with short half-times of repair of the order of a few minutes, similar to pulse durations. Methods and Materials: Calculations were done assuming the linear quadratic formula for radiation damage, in which only the dose-squared term is subject to exponential repair. The situation with two components of T (1(2)) is addressed. A constant overall time of 140 h and a constant total dose of 70 Gy were assumed throughout, the continuous low dose rate of 0.5 Gy/h (CLDR) providing the unitary standard effects for each PDR condition. Effects of dose rates ranging from 4 Gy/h to 120 Gy/h (HDR at 2 Gy/min) were studied, covering the gap in an earlier publication. Four schedules were examined: doses per pulse of 0.5, 1, 1.5, and 2 Gy given at repetition frequencies of 1, 2, 3, and 4 h, respectively, each with a range of assumed half-times of repair of 4 min to 1.5 h. Results are presented for late-responding tissues, the differences from CLDR being two or three times greater than for early-responding tissues and most tumors. Results: Curves are presented relating the ratio of increased biological effect (proportional to log cell kill) calculated for PDR relative to CLDR. Ratios as high as 1.5 can be found for large doses per pulse (2 Gy) if the half-time of repair in tissues is as short as a few minutes. The major influences on effect are dose per pulse, half-time of repair in tissue, and--when T (1(2)) is short--the instantaneous dose rate. Maximum ratios of PDR/CLDR occur when the dose rate is such that pulse duration is approximately equal to T (1(2)) . As dose rate in the pulse is increased, a plateau of effect is reached, for most T (1(2)) s, above 10 to 20 Gy/h, which is

  7. Validation of the NPAQ-short - a brief questionnaire to monitor physical activity and compliance with the WHO recommendations

    DEFF Research Database (Denmark)

    Danquah, Ida Høgstedt; Petersen, Christina Bjørk; Skov, Sofie Smedegaard

    2018-01-01

    BACKGROUND: Using self-reported surveys to monitor physical activity levels in the population require short items covering both time and intensity. The present study aims to 1) develop the Nordic Physical Activity Questionnaire-short from the original version of the NPAQ, 2) assess test...... when using both open and closed-ended questions. However, using open-ended questions seems to be a better answering mode for self-reported surveys monitoring WHO's physical activity recommendations.......-retest reliability and criterion validity of the NPAQ-short, and 3) test the NPAQ-short's ability to monitor compliance with the WHO recommendations on physical activity. In addition, we aimed to compare open and closed-ended answering modes for the NPAQ-short. METHODS: A sample of 122 participants were included...

  8. Incorporating geostrophic wind information for improved space–time short-term wind speed forecasting

    KAUST Repository

    Zhu, Xinxin

    2014-09-01

    Accurate short-term wind speed forecasting is needed for the rapid development and efficient operation of wind energy resources. This is, however, a very challenging problem. Although on the large scale, the wind speed is related to atmospheric pressure, temperature, and other meteorological variables, no improvement in forecasting accuracy was found by incorporating air pressure and temperature directly into an advanced space-time statistical forecasting model, the trigonometric direction diurnal (TDD) model. This paper proposes to incorporate the geostrophic wind as a new predictor in the TDD model. The geostrophic wind captures the physical relationship between wind and pressure through the observed approximate balance between the pressure gradient force and the Coriolis acceleration due to the Earth’s rotation. Based on our numerical experiments with data from West Texas, our new method produces more accurate forecasts than does the TDD model using air pressure and temperature for 1to 6-hour-ahead forecasts based on three different evaluation criteria. Furthermore, forecasting errors can be further reduced by using moving average hourly wind speeds to fit the diurnal pattern. For example, our new method obtains between 13.9% and 22.4% overall mean absolute error reduction relative to persistence in 2-hour-ahead forecasts, and between 5.3% and 8.2% reduction relative to the best previous space-time methods in this setting.

  9. Comparison of short term rainfall forecasts for model based flow prediction in urban drainage systems

    DEFF Research Database (Denmark)

    Thorndahl, Søren; Poulsen, Troels Sander; Bøvith, Thomas

    2012-01-01

    Forecast based flow prediction in drainage systems can be used to implement real time control of drainage systems. This study compares two different types of rainfall forecasts – a radar rainfall extrapolation based nowcast model and a numerical weather prediction model. The models are applied...... performance of the system is found using the radar nowcast for the short leadtimes and weather model for larger lead times....

  10. Short- versus long-term radon detectors: a comparative study in Galicia, NW Spain

    International Nuclear Information System (INIS)

    Ruano-Ravina, A.; Castro-Bernardez, M.; Sande-Meijide, M.; Vargas, A.; Barros-Dios, J.M.

    2008-01-01

    As reported in previous studies, Galicia (NW Spain) is an area of high radon concentrations. This study was sought to analyze the correlation between short-term (activated carbon) and long-term (alpha particle track) detectors in this geographic area, and ascertain whether there were differences in their readings that might be influenced by other variables. A comparison study, as part of a case-control study was designed in which two detectors, one of each type, were placed in the selected homes. A total of 391 homes yielded readings with both detectors. The results indicated that there was a relatively good correlation between both types of monitors (correlation coefficient 0.608; p < 0.001). The highest correlations between both detectors were observed for unventilated homes, coastal sites, and the oldest buildings. Short-term and long-term detectors do not show a similar performance in all settings or situations. It is advisable to use long-term detectors whenever possible

  11. Short- versus long-term radon detectors: a comparative study in Galicia, NW Spain

    Energy Technology Data Exchange (ETDEWEB)

    Ruano-Ravina, A. [Department of Preventive Medicine and Public Health, School of Medicine, University of Santiago de Compostela, C/San Francisco s/n, 15782 Santiago de Compostela (Spain); Galician Agency for Health Technology Assessment, Galician Health Service, Santiago de Compostela (Spain); CIBER de Epidemiologia y Salud Publica, CIBERESP (Spain)], E-mail: mralbert@usc.es; Castro-Bernardez, M. [Epidemiology Department, Directorate-General for Public Health, Galician Regional Authority (Spain); Sande-Meijide, M. [Preventive Medicine Unit, Ourense Hospital Complex, Galician Health Service (Spain); Vargas, A. [Energy Techniques Institute, Polytechnic University of Catalonia, Barcelona (Spain); Barros-Dios, J.M. [Department of Preventive Medicine and Public Health, School of Medicine, University of Santiago de Compostela, C/San Francisco s/n, 15782 Santiago de Compostela (Spain); CIBER de Epidemiologia y Salud Publica, CIBERESP (Spain); Preventive Medicine Unit, Santiago de Compostela University Hospital, Galician Health Service (Spain)

    2008-07-15

    As reported in previous studies, Galicia (NW Spain) is an area of high radon concentrations. This study was sought to analyze the correlation between short-term (activated carbon) and long-term (alpha particle track) detectors in this geographic area, and ascertain whether there were differences in their readings that might be influenced by other variables. A comparison study, as part of a case-control study was designed in which two detectors, one of each type, were placed in the selected homes. A total of 391 homes yielded readings with both detectors. The results indicated that there was a relatively good correlation between both types of monitors (correlation coefficient 0.608; p < 0.001). The highest correlations between both detectors were observed for unventilated homes, coastal sites, and the oldest buildings. Short-term and long-term detectors do not show a similar performance in all settings or situations. It is advisable to use long-term detectors whenever possible.

  12. Learning From Short Text Streams With Topic Drifts.

    Science.gov (United States)

    Li, Peipei; He, Lu; Wang, Haiyan; Hu, Xuegang; Zhang, Yuhong; Li, Lei; Wu, Xindong

    2017-09-18

    Short text streams such as search snippets and micro blogs have been popular on the Web with the emergence of social media. Unlike traditional normal text streams, these data present the characteristics of short length, weak signal, high volume, high velocity, topic drift, etc. Short text stream classification is hence a very challenging and significant task. However, this challenge has received little attention from the research community. Therefore, a new feature extension approach is proposed for short text stream classification with the help of a large-scale semantic network obtained from a Web corpus. It is built on an incremental ensemble classification model for efficiency. First, more semantic contexts based on the senses of terms in short texts are introduced to make up of the data sparsity using the open semantic network, in which all terms are disambiguated by their semantics to reduce the noise impact. Second, a concept cluster-based topic drifting detection method is proposed to effectively track hidden topic drifts. Finally, extensive studies demonstrate that as compared to several well-known concept drifting detection methods in data stream, our approach can detect topic drifts effectively, and it enables handling short text streams effectively while maintaining the efficiency as compared to several state-of-the-art short text classification approaches.

  13. Fetal short time variation during labor: a non-invasive alternative to fetal scalp pH measurements?

    Science.gov (United States)

    Schiermeier, Sven; Reinhard, Joscha; Hatzmann, Hendrike; Zimmermann, Ralf C; Westhof, Gregor

    2009-01-01

    To determine whether short time variation (STV) of fetal heart beat correlates with scalp pH measurements during labor. From 1279 deliveries, 197 women had at least one fetal scalp pH measurement. Using the CTG-Player, STVs were calculated from the electronically saved cardiotocography (CTG) traces and related to the fetal scalp pH measurements. There was no correlation between STV and fetal scalp pH measurements (r=-0.0592). Fetal STV is an important parameter with high sensitivity for antenatal fetal acidosis. This study shows that STV calculations do not correlate with fetal scalp pH measurements during labor, hence are not helpful in identifying fetal acidosis.

  14. Mechanical Properties, Short Time Creep, and Fatigue of an Austenitic Steel

    Directory of Open Access Journals (Sweden)

    Josip Brnic

    2016-04-01

    Full Text Available The correct choice of a material in the process of structural design is the most important task. This study deals with determining and analyzing the mechanical properties of the material, and the material resistance to short-time creep and fatigue. The material under consideration in this investigation is austenitic stainless steel X6CrNiTi18-10. The results presenting ultimate tensile strength and 0.2 offset yield strength at room and elevated temperatures are displayed in the form of engineering stress-strain diagrams. Besides, the creep behavior of the steel is presented in the form of creep curves. The material is consequently considered to be creep resistant at temperatures of 400 °C and 500 °C when subjected to a stress which is less than 0.9 of the yield strength at the mentioned temperatures. Even when the applied stress at a temperature of 600 °C is less than 0.5 of the yield strength, the steel may be considered as resistant to creep. Cyclic tensile fatigue tests were carried out at stress ratio R = 0.25 using a servo-pulser machine and the results were recorded. The analysis shows that the stress level of 434.33 MPa can be adopted as a fatigue limit. The impact energy was also determined and the fracture toughness assessed.

  15. Mechanical Properties, Short Time Creep, and Fatigue of an Austenitic Steel.

    Science.gov (United States)

    Brnic, Josip; Turkalj, Goran; Canadija, Marko; Lanc, Domagoj; Krscanski, Sanjin; Brcic, Marino; Li, Qiang; Niu, Jitai

    2016-04-20

    The correct choice of a material in the process of structural design is the most important task. This study deals with determining and analyzing the mechanical properties of the material, and the material resistance to short-time creep and fatigue. The material under consideration in this investigation is austenitic stainless steel X6CrNiTi18-10. The results presenting ultimate tensile strength and 0.2 offset yield strength at room and elevated temperatures are displayed in the form of engineering stress-strain diagrams. Besides, the creep behavior of the steel is presented in the form of creep curves. The material is consequently considered to be creep resistant at temperatures of 400 °C and 500 °C when subjected to a stress which is less than 0.9 of the yield strength at the mentioned temperatures. Even when the applied stress at a temperature of 600 °C is less than 0.5 of the yield strength, the steel may be considered as resistant to creep. Cyclic tensile fatigue tests were carried out at stress ratio R = 0.25 using a servo-pulser machine and the results were recorded. The analysis shows that the stress level of 434.33 MPa can be adopted as a fatigue limit. The impact energy was also determined and the fracture toughness assessed.

  16. The effect of badminton-specific exercise on badminton short-serve performance in competition and practice climates.

    Science.gov (United States)

    Duncan, Michael J; Chan, Cheryl K Y; Clarke, Neil D; Cox, Martin; Smith, Mike

    2017-03-01

    This study examined the effects of changes in physiological and psychological arousal on badminton short-serve performance in competitive and practice climates. Twenty competitive badminton players (10 males and 10 females) volunteered to participate in the study following ethics approval. After familiarisation, badminton short-serve performance was measured at rest, mid-way through and at the end of a badminton-specific exercise protocol in two conditions; competition vs. practice. Ratings of cognitive and somatic anxiety were assessed at three time points prior to badminton short-serve performance using the Mental Readiness Form 3. Heart rate and rating of perceived exertion (RPE) were assessed during the exercise protocol. Results indicated that better short-serve performance was evident in practice compared to competition (P = .034). RPE values were significantly higher in the competition condition compared to practice (P = .007). Cognitive anxiety intensity was significantly lower post-exercise in the practice condition compared to competition (P = .001). Cognitive anxiety direction showed greater debilitation post-exercise in the competition condition compared to practice (P = .01). Somatic anxiety intensity increased from pre-, to mid- to post-exercise (P = .001) irrespective of condition. This study suggests that badminton serve performance is negatively affected when physiological arousal, via badminton-specific exercise, and cognitive anxiety, via perceived competition, are high.

  17. Domain-Generality of Timing-Based Serial Order Processes in Short-Term Memory: New Insights from Musical and Verbal Domains.

    Directory of Open Access Journals (Sweden)

    Simon Gorin

    Full Text Available Several models in the verbal domain of short-term memory (STM consider a dissociation between item and order processing. This view is supported by data demonstrating that different types of time-based interference have a greater effect on memory for the order of to-be-remembered items than on memory for the items themselves. The present study investigated the domain-generality of the item versus serial order dissociation by comparing the differential effects of time-based interfering tasks, such as rhythmic interference and articulatory suppression, on item and order processing in verbal and musical STM domains. In Experiment 1, participants had to maintain sequences of verbal or musical information in STM, followed by a probe sequence, this under different conditions of interference (no-interference, rhythmic interference, articulatory suppression. They were required to decide whether all items of the probe list matched those of the memory list (item condition or whether the order of the items in the probe sequence matched the order in the memory list (order condition. In Experiment 2, participants performed a serial order probe recognition task for verbal and musical sequences ensuring sequential maintenance processes, under no-interference or rhythmic interference conditions. For Experiment 1, serial order recognition was not significantly more impacted by interfering tasks than was item recognition, this for both verbal and musical domains. For Experiment 2, we observed selective interference of the rhythmic interference condition on both musical and verbal order STM tasks. Overall, the results suggest a similar and selective sensitivity to time-based interference for serial order STM in verbal and musical domains, but only when the STM tasks ensure sequential maintenance processes.

  18. Domain-Generality of Timing-Based Serial Order Processes in Short-Term Memory: New Insights from Musical and Verbal Domains.

    Science.gov (United States)

    Gorin, Simon; Kowialiewski, Benjamin; Majerus, Steve

    2016-01-01

    Several models in the verbal domain of short-term memory (STM) consider a dissociation between item and order processing. This view is supported by data demonstrating that different types of time-based interference have a greater effect on memory for the order of to-be-remembered items than on memory for the items themselves. The present study investigated the domain-generality of the item versus serial order dissociation by comparing the differential effects of time-based interfering tasks, such as rhythmic interference and articulatory suppression, on item and order processing in verbal and musical STM domains. In Experiment 1, participants had to maintain sequences of verbal or musical information in STM, followed by a probe sequence, this under different conditions of interference (no-interference, rhythmic interference, articulatory suppression). They were required to decide whether all items of the probe list matched those of the memory list (item condition) or whether the order of the items in the probe sequence matched the order in the memory list (order condition). In Experiment 2, participants performed a serial order probe recognition task for verbal and musical sequences ensuring sequential maintenance processes, under no-interference or rhythmic interference conditions. For Experiment 1, serial order recognition was not significantly more impacted by interfering tasks than was item recognition, this for both verbal and musical domains. For Experiment 2, we observed selective interference of the rhythmic interference condition on both musical and verbal order STM tasks. Overall, the results suggest a similar and selective sensitivity to time-based interference for serial order STM in verbal and musical domains, but only when the STM tasks ensure sequential maintenance processes.

  19. Time-Series Prediction: Application to the Short-Term Electric Energy Demand

    OpenAIRE

    Troncoso Lora, Alicia; Riquelme Santos, Jesús Manuel; Riquelme Santos, José Cristóbal; Gómez Expósito, Antonio; Martínez Ramos, José Luis

    2003-01-01

    This paper describes a time-series prediction method based on the kNN technique. The proposed methodology is applied to the 24-hour load forecasting problem. Also, based on recorded data, an alternative model is developed by means of a conventional dynamic regression technique, where the parameters are estimated by solving a least squares problem. Finally, results obtained from the application of both techniques to the Spanish transmission system are compared in terms of maximum, average and ...

  20. Automatized near-real-time short-term Probabilistic Volcanic Hazard Assessment of tephra dispersion before eruptions: BET_VHst for Vesuvius and Campi Flegrei during recent exercises

    Science.gov (United States)

    Selva, Jacopo; Costa, Antonio; Sandri, Laura; Rouwet, Dmtri; Tonini, Roberto; Macedonio, Giovanni; Marzocchi, Warner

    2015-04-01

    Probabilistic Volcanic Hazard Assessment (PVHA) represents the most complete scientific contribution for planning rational strategies aimed at mitigating the risk posed by volcanic activity at different time scales. The definition of the space-time window for PVHA is related to the kind of risk mitigation actions that are under consideration. Short temporal intervals (days to weeks) are important for short-term risk mitigation actions like the evacuation of a volcanic area. During volcanic unrest episodes or eruptions, it is of primary importance to produce short-term tephra fallout forecast, and frequently update it to account for the rapidly evolving situation. This information is obviously crucial for crisis management, since tephra may heavily affect building stability, public health, transportations and evacuation routes (airports, trains, road traffic) and lifelines (electric power supply). In this study, we propose a methodology named BET_VHst (Selva et al. 2014) for short-term PVHA of volcanic tephra dispersal based on automatic interpretation of measures from the monitoring system and physical models of tephra dispersal from all possible vent positions and eruptive sizes based on frequently updated meteorological forecasts. The large uncertainty at all the steps required for the analysis, both aleatory and epistemic, is treated by means of Bayesian inference and statistical mixing of long- and short-term analyses. The BET_VHst model is here presented through its implementation during two exercises organized for volcanoes in the Neapolitan area: MESIMEX for Mt. Vesuvius, and VUELCO for Campi Flegrei. References Selva J., Costa A., Sandri L., Macedonio G., Marzocchi W. (2014) Probabilistic short-term volcanic hazard in phases of unrest: a case study for tephra fallout, J. Geophys. Res., 119, doi: 10.1002/2014JB011252

  1. Development of High Temperature Short Time Vertebrate-Blood Pasteurization Equipment for Tsetse Fly Diets

    Energy Technology Data Exchange (ETDEWEB)

    Moravek, I; Lach, J [Department of Manufacturing Systems, Slovak Technical University Namestie Slobody 17 812 31 Bratislava (Slovakia); Takac, P [Institute of Zoology, SAV, Bratislava (Slovakia)

    2012-07-15

    Tsetse flies feed only on vertebrate blood, but the collection and processing of blood is expensive, it must be stored at -20{sup o}C requiring costly storage rooms and reliable electricity, and it must be irradiated to reduce bacterial contamination. This is tolerable for small colonies, but as colony size increases to service large- scale programmes, the supply and processing of blood becomes critical. Blood is normally collected from cattle at slaughter. This process is necessarily not aseptic, and large-scale collection is only possible where the animals are suspended for bleeding. One alternative to blood decontamination is using the High Temperature Short time Pasteurization (HTST) method. The food processing industry uses pasteurization to reduce bacterial load in a wide range of products. Our previous results indicated that for the control of the blood pasteurization process, to reach satisfactory bacteriological purity and at the same time to prevent the blood from coagulating, it is important to study temperature and time and also some other parameters that could predict blood coagulation. Crucial for blood coagulation is to study blood viscosity. Classical heat exchangers are not suitable for blood pasteurization. In such equipment the blood coagulation depends on temperature and time. Besides the relatively low temperatures, blood is coagulating with cumulative time until total shutdown of blood flow. After a series of experiments we found a solution using microwave systems. To verify the microwave heating concept, we built an experimental workstation. First we verified the accuracy of the applicator design from the aspect of output adaptation to the power source. Also we installed measuring equipment. This system complies with the requirements of quick heating with sufficiently high heat accumulation. By utilizing standard components for the base of the microwave generator, it is possible to markedly reduce the final price of the equipment. (author)

  2. No Clear Association between Impaired Short-Term or Working Memory Storage and Time Reproduction Capacity in Adult ADHD Patients.

    Science.gov (United States)

    Mette, Christian; Grabemann, Marco; Zimmermann, Marco; Strunz, Laura; Scherbaum, Norbert; Wiltfang, Jens; Kis, Bernhard

    2015-01-01

    Altered time reproduction is exhibited by patients with adult attention deficit hyperactivity disorder (ADHD). It remains unclear whether memory capacity influences the ability of adults with ADHD to reproduce time intervals. We conducted a behavioral study on 30 ADHD patients who were medicated with methylphenidate, 29 unmedicated adult ADHD patients and 32 healthy controls (HCs). We assessed time reproduction using six time intervals (1 s, 4 s, 6 s, 10 s, 24 s and 60 s) and assessed memory performance using the Wechsler memory scale. The patients with ADHD exhibited lower memory performance scores than the HCs. No significant differences in the raw scores for any of the time intervals (p > .05), with the exception of the variability at the short time intervals (1 s, 4 s and 6 s) (p memory performance (p > .05). We detected no findings indicating that working memory might influence time reproduction in adult patients with ADHD. Therefore, further studies concerning time reproduction and memory capacity among adult patients with ADHD must be performed to verify and replicate the present findings.

  3. No Clear Association between Impaired Short-Term or Working Memory Storage and Time Reproduction Capacity in Adult ADHD Patients.

    Directory of Open Access Journals (Sweden)

    Christian Mette

    Full Text Available Altered time reproduction is exhibited by patients with adult attention deficit hyperactivity disorder (ADHD. It remains unclear whether memory capacity influences the ability of adults with ADHD to reproduce time intervals.We conducted a behavioral study on 30 ADHD patients who were medicated with methylphenidate, 29 unmedicated adult ADHD patients and 32 healthy controls (HCs. We assessed time reproduction using six time intervals (1 s, 4 s, 6 s, 10 s, 24 s and 60 s and assessed memory performance using the Wechsler memory scale.The patients with ADHD exhibited lower memory performance scores than the HCs. No significant differences in the raw scores for any of the time intervals (p > .05, with the exception of the variability at the short time intervals (1 s, 4 s and 6 s (p .05.We detected no findings indicating that working memory might influence time reproduction in adult patients with ADHD. Therefore, further studies concerning time reproduction and memory capacity among adult patients with ADHD must be performed to verify and replicate the present findings.

  4. Metabolite concentrations in supraventricular white matter from teenage to early old age: A short echo time 1H magnetic resonance spectroscopy (MRS) study

    Energy Technology Data Exchange (ETDEWEB)

    Raininko, Raili (Dept. of Radiology, Uppsala Univ., Uppsala (Sweden)), e-mail: raili.raininko@radiol.uu.se; Mattsson, Peter (Dept. of Neuroscience, Neurology, Uppsala Univ., Uppsala (Sweden))

    2010-04-15

    Background: Age- and sex-related changes of metabolites in healthy adult brains have been examined with different 1H magnetic resonance spectroscopy (MRS) methods in varying populations, and with differing results. A long repetition time and short echo time technique reduces quantification errors due to T1 and T2 relaxation effects and makes it possible to measure metabolites with short T2 relaxation times. Purpose: To examine the effect of age on the metabolite concentrations measured by 1H MRS in normal supraventricular white matter using a long repetition time (TR) and a short echo time (TE). Material and Methods: Supraventricular white matter of 57 healthy subjects (25 women, 32 men), aged 13 to 72 years, was examined with a single-voxel MRS at 1.5T using a TR of 6000 ms and a TE of 22 ms. Tissue water was used as a reference in quantification. Results: Myoinositol increased slightly and total N-acetyl aspartate (NAA) decreased slightly with increasing age. Glutamine/glutamate complex (Glx) showed U-shaped age dependence, with highest concentrations in the youngest and oldest subjects. No significant age dependence was found in total choline and total creatine. No gender differences were found. Macromolecule/ lipid (ML) fractions were reliably measurable only in 36/57 or even fewer subjects and showed very large deviations. Conclusion: The concentrations of several metabolites in cerebral supraventricular white matter are age dependent on 1H MRS, even in young and middle-aged people, and age dependency can be nonlinear. Each 1H MRS study of the brain should therefore take age into account, whereas sex does not appear to be so important. The use of macromolecule and lipid evaluations is compromised by less successful quantification and large variations in healthy people

  5. Metabolite concentrations in supraventricular white matter from teenage to early old age: A short echo time 1H magnetic resonance spectroscopy (MRS) study

    International Nuclear Information System (INIS)

    Raininko, Raili; Mattsson, Peter

    2010-01-01

    Background: Age- and sex-related changes of metabolites in healthy adult brains have been examined with different 1 H magnetic resonance spectroscopy (MRS) methods in varying populations, and with differing results. A long repetition time and short echo time technique reduces quantification errors due to T1 and T2 relaxation effects and makes it possible to measure metabolites with short T2 relaxation times. Purpose: To examine the effect of age on the metabolite concentrations measured by 1H MRS in normal supraventricular white matter using a long repetition time (TR) and a short echo time (TE). Material and Methods: Supraventricular white matter of 57 healthy subjects (25 women, 32 men), aged 13 to 72 years, was examined with a single-voxel MRS at 1.5T using a TR of 6000 ms and a TE of 22 ms. Tissue water was used as a reference in quantification. Results: Myoinositol increased slightly and total N-acetyl aspartate (NAA) decreased slightly with increasing age. Glutamine/glutamate complex (Glx) showed U-shaped age dependence, with highest concentrations in the youngest and oldest subjects. No significant age dependence was found in total choline and total creatine. No gender differences were found. Macromolecule/ lipid (ML) fractions were reliably measurable only in 36/57 or even fewer subjects and showed very large deviations. Conclusion: The concentrations of several metabolites in cerebral supraventricular white matter are age dependent on 1H MRS, even in young and middle-aged people, and age dependency can be nonlinear. Each 1H MRS study of the brain should therefore take age into account, whereas sex does not appear to be so important. The use of macromolecule and lipid evaluations is compromised by less successful quantification and large variations in healthy people

  6. Dreaming during sevoflurane or propofol short-term sedation: a randomised controlled trial.

    Science.gov (United States)

    Xu, G H; Liu, X S; Yu, F Q; Gu, E W; Zhang, J; Royse, A G; Wang, K

    2012-05-01

    Prior reports suggest that dreaming during anaesthesia is dependent on recovery time. Dreaming during sedation may impact patient satisfaction. The current study explores the incidence and content of dreaming during short-term sedation with sevoflurane or propofol and investigates whether dreaming is affected by recovery time. A total of 200 women undergoing first trimester abortion (American Society of Anesthesiologists physical status I) participated in the study. Patients were randomly assigned to receive either sevoflurane or propofol for short-term sedation. Patients were interviewed upon emergence with the modified Brice questionnaire. The results showed the incidence of dreaming was significantly different between anaesthesia groups with 60% (60/100) of the sevoflurane group and 33% (33/100) of the propofol group (P=0.000). However, recovery time did not significantly differ between groups. In the sevoflurane group, a greater number of dreamers could not recall what they had dreamed about (P=0.02) and more patients reported dreams that had no sound (P=0.03) or movement (P=0.001) compared with dreamers in the propofol group. Most participants reported dreams with positive emotional content and this did not significantly differ between groups. Anaesthesia administered had no effect on patient satisfaction. The results suggest that the incidence of dreaming was not affected by recovery time. Patient satisfaction was not influenced by choice of sedative and/or by the occurrence of dreaming during sevoflurane or propofol short-term sedation.

  7. A deep learning framework for financial time series using stacked autoencoders and long-short term memory

    Science.gov (United States)

    Bao, Wei; Rao, Yulei

    2017-01-01

    The application of deep learning approaches to finance has received a great deal of attention from both investors and researchers. This study presents a novel deep learning framework where wavelet transforms (WT), stacked autoencoders (SAEs) and long-short term memory (LSTM) are combined for stock price forecasting. The SAEs for hierarchically extracted deep features is introduced into stock price forecasting for the first time. The deep learning framework comprises three stages. First, the stock price time series is decomposed by WT to eliminate noise. Second, SAEs is applied to generate deep high-level features for predicting the stock price. Third, high-level denoising features are fed into LSTM to forecast the next day’s closing price. Six market indices and their corresponding index futures are chosen to examine the performance of the proposed model. Results show that the proposed model outperforms other similar models in both predictive accuracy and profitability performance. PMID:28708865

  8. A deep learning framework for financial time series using stacked autoencoders and long-short term memory.

    Directory of Open Access Journals (Sweden)

    Wei Bao

    Full Text Available The application of deep learning approaches to finance has received a great deal of attention from both investors and researchers. This study presents a novel deep learning framework where wavelet transforms (WT, stacked autoencoders (SAEs and long-short term memory (LSTM are combined for stock price forecasting. The SAEs for hierarchically extracted deep features is introduced into stock price forecasting for the first time. The deep learning framework comprises three stages. First, the stock price time series is decomposed by WT to eliminate noise. Second, SAEs is applied to generate deep high-level features for predicting the stock price. Third, high-level denoising features are fed into LSTM to forecast the next day's closing price. Six market indices and their corresponding index futures are chosen to examine the performance of the proposed model. Results show that the proposed model outperforms other similar models in both predictive accuracy and profitability performance.

  9. Seasonal time series forecasting: a comparative study of arima and ...

    African Journals Online (AJOL)

    This paper addresses the concerns of Faraway and Chatfield (1998) who questioned the forecasting ability of Artificial Neural Networks (ANN). In particular the paper compares the performance of Artificial Neural Networks (ANN) and ARIMA models in forecasting of seasonal (monthly) Time series. Using the Airline data ...

  10. A voxel-based investigation for MRI-only radiotherapy of the brain using ultra short echo times

    Science.gov (United States)

    Edmund, Jens M.; Kjer, Hans M.; Van Leemput, Koen; Hansen, Rasmus H.; Andersen, Jon AL; Andreasen, Daniel

    2014-12-01

    Radiotherapy (RT) based on magnetic resonance imaging (MRI) as the only modality, so-called MRI-only RT, would remove the systematic registration error between MR and computed tomography (CT), and provide co-registered MRI for assessment of treatment response and adaptive RT. Electron densities, however, need to be assigned to the MRI images for dose calculation and patient setup based on digitally reconstructed radiographs (DRRs). Here, we investigate the geometric and dosimetric performance for a number of popular voxel-based methods to generate a so-called pseudo CT (pCT). Five patients receiving cranial irradiation, each containing a co-registered MRI and CT scan, were included. An ultra short echo time MRI sequence for bone visualization was used. Six methods were investigated for three popular types of voxel-based approaches; (1) threshold-based segmentation, (2) Bayesian segmentation and (3) statistical regression. Each approach contained two methods. Approach 1 used bulk density assignment of MRI voxels into air, soft tissue and bone based on logical masks and the transverse relaxation time T2 of the bone. Approach 2 used similar bulk density assignments with Bayesian statistics including or excluding additional spatial information. Approach 3 used a statistical regression correlating MRI voxels with their corresponding CT voxels. A similar photon and proton treatment plan was generated for a target positioned between the nasal cavity and the brainstem for all patients. The CT agreement with the pCT of each method was quantified and compared with the other methods geometrically and dosimetrically using both a number of reported metrics and introducing some novel metrics. The best geometrical agreement with CT was obtained with the statistical regression methods which performed significantly better than the threshold and Bayesian segmentation methods (excluding spatial information). All methods agreed significantly better with CT than a reference water MRI

  11. Finite-size effects in the short-time height distribution of the Kardar-Parisi-Zhang equation

    Science.gov (United States)

    Smith, Naftali R.; Meerson, Baruch; Sasorov, Pavel

    2018-02-01

    We use the optimal fluctuation method to evaluate the short-time probability distribution P(H, L, t) of height at a single point, H=h(x=0, t) , of the evolving Kardar-Parisi-Zhang (KPZ) interface h(x, t) on a ring of length 2L. The process starts from a flat interface. At short times typical (small) height fluctuations are unaffected by the KPZ nonlinearity and belong to the Edwards-Wilkinson universality class. The nonlinearity, however, strongly affects the (asymmetric) tails of P(H) . At large L/\\sqrt{t} the faster-decaying tail has a double structure: it is L-independent, -\\lnP˜≤ft\\vert H\\right\\vert 5/2/t1/2 , at intermediately large \\vert H\\vert , and L-dependent, -\\lnP˜ ≤ft\\vert H\\right\\vert 2L/t , at very large \\vert H\\vert . The transition between these two regimes is sharp and, in the large L/\\sqrt{t} limit, behaves as a fractional-order phase transition. The transition point H=Hc+ depends on L/\\sqrt{t} . At small L/\\sqrt{t} , the double structure of the faster tail disappears, and only the very large-H tail, -\\lnP˜ ≤ft\\vert H\\right\\vert 2L/t , is observed. The slower-decaying tail does not show any L-dependence at large L/\\sqrt{t} , where it coincides with the slower tail of the GOE Tracy-Widom distribution. At small L/\\sqrt{t} this tail also has a double structure. The transition between the two regimes occurs at a value of height H=Hc- which depends on L/\\sqrt{t} . At L/\\sqrt{t} \\to 0 the transition behaves as a mean-field-like second-order phase transition. At \\vert H\\vert c-\\vert the slower tail behaves as -\\lnP˜ ≤ft\\vert H\\right\\vert 2L/t , whereas at \\vert H\\vert >\\vert H_c-\\vert it coincides with the slower tail of the GOE Tracy-Widom distribution.

  12. Severe symptoms of short tear break-up time dry eye are associated with accommodative microfluctuations

    Directory of Open Access Journals (Sweden)

    Kaido M

    2017-05-01

    Full Text Available Minako Kaido,1,2 Motoko Kawashima,1 Reiko Ishida,1,3 Kazuo Tsubota1 1Department of Ophthalmology, Keio University School of Medicine, Tokyo, 2Wada Eye Clinic, Chiba, 3Ishida Eye Clinic, Shizuoka, Japan Aim: Validating the hypothesis that accommodative microfluctuations (AMFs may be associated with severe symptoms in short tear break-up time (BUT dry eye (DE. Methods: This study included 12 subjects with short BUT DE (age: 49.6±18.3 years. Diagnoses were performed based on the presence of DE symptoms, BUT ≤5 s, Schirmer score >5 mm, and negative keratoconjunctival epithelial damage. Tear evaluation, AMF, and functional visual acuity (VA examinations were conducted before and after DE treatment. The AMF parameters evaluated were: total high-frequency component (HFC, HFC with low accommodation for the task of staring into the distance (HFC1, HFC with high accommodation for deskwork (HFC2. A subjective questionnaire of DE symptoms was also performed. Results: Mean BUT increased from 1.9±2.0 to 6.4±2.5 s after treatment (P<0.05. The mean logarithm of the minimum angle of resolution functional VA significantly improved (from 0.19±0.19 to 0.12±0.17; P<0.05. Mean power spectrum values for total HFC and HFC1 decreased (from 61.3±5.7 to 53.8±6.6 dB and from 62.9±10.5 to 52.4±6.2 dB, respectively; P<0.05, while the mean HFC2 power spectrum values did not differ before and after treatment (P>0.05. Subjective DE symptoms were reduced in nine patients. Conclusion: Along with the improvement of BUT after treatment, DE symptoms diminished and HFC1 and functional VA improved, suggesting that tear film instability is associated with deterioration of functional VA, AMF, and DE symptoms. Keywords: accommodative microfluctuation, ciliary muscle spasm, dry eye, ocular fatigue, tear break-up time, functional visual acuity 

  13. Short- and long-term outcomes of metformin compared with insulin alone in pregnancy: a systematic review and meta-analysis.

    Science.gov (United States)

    Butalia, S; Gutierrez, L; Lodha, A; Aitken, E; Zakariasen, A; Donovan, L

    2017-01-01

    To assess the short- and long-term maternal and fetal impact of metformin in pregnancy compared with insulin. We performed a comprehensive literature search of MEDLINE, EMBASE, BIOSIS, Cochrane Database of Systematic Reviews and ClinicalTrials.gov. Eligible studies were randomized control trials (RCTs) or follow-up of an RCT that: (1) compared metformin with insulin in pregnancy in women with gestational diabetes mellitus or Type 2 diabetes; and (2) reported maternal or fetal outcomes of interest. Two reviewers extracted the data, evaluated study quality and calculated pooled estimates. Sixteen studies (n = 2165 in quantitative analysis) were included. Metformin lowered the risk of neonatal hypoglycaemia [risk ratio (RR) = 0.63; 95% confidence interval (95% CI), 0.45 to 0.87], large for gestational age babies (RR = 0.80; 95% CI, 0.64 to 0.99), pregnancy-induced hypertension (RR = 0.56; 95% CI, 0.37 to 0.85) and total maternal pregnancy weight gain [mean difference (MD) -2.07; 95% CI -2.88 to -1.27]. Metformin did not increase preterm delivery (RR = 1.18; 95% CI 0.67 to 2.07), small for gestational age babies (RR = 1.20; 95% CI, 0.67 to 2.14), perinatal mortality (RR = 0.82; 95% CI, 0.17 to 3.92) or Caesarean section (RR = 0.97; 95% CI, 0.80 to 1.19). Long-term outcome information is limited. Our review found that metformin had no short-term adverse effects on pregnancy, potential benefits in the neonatal period, but limited long-term follow-up information. Prior to routine use, we recommend further follow-up studies of offspring exposed to metformin in utero. © 2016 Diabetes UK.

  14. Time-delay analyzer with continuous discretization

    International Nuclear Information System (INIS)

    Bayatyan, G.L.; Darbinyan, K.T.; Mkrtchyan, K.K.; Stepanyan, S.S.

    1988-01-01

    A time-delay analyzer is described which when triggered by a start pulse of adjustable duration performs continuous discretization of the analyzed signal within nearly 22 ns time intervals, the recording in a memory unit with following slow read-out of the information to the computer and its processing. The time-delay analyzer consists of four CAMAC-VECTOR systems of unit width. With its help one can separate comparatively short, small-amplitude rare signals against the background of quasistationary noise processes. 4 refs.; 3 figs

  15. Methods for short-term control of Imperata grass in Peruvian Amazon

    Directory of Open Access Journals (Sweden)

    Zbynek Polesny

    2011-06-01

    Full Text Available The traditional control of Imperata brasiliensis grasslands used by farmers in the Peruvian Amazon is to burn the grass. The objective of this study was to compare different methods of short-term control. Biological, mechanical, chemical and traditional methods of control were compared. Herbicide spraying and manual weeding have shown to be very effective in reducing above- and below-ground biomass growth in the first 45 days after slashing the grass, with effects persisting in the longer term, but both are expensive methods. Shading seems to be less effective in the short-term, whereas it influences the Imperata growth in the longer term. After one year shading, glyphosate application and weeding significantly reduced aboveground biomass by 94, 67 and 53%; and belowground biomass by 76, 65 and 58%, respectively, compared to control. We also found a significant decrease of Imperata rhizomes in soil during time under shading. Burning has proved to have no significant effect on Imperata growth. The use of shade trees in a kind of agroforestry system could be a suitable method for small farmers to control Imperata grasslands.

  16. Genetic deletion of melanin-concentrating hormone neurons impairs hippocampal short-term synaptic plasticity and hippocampal-dependent forms of short-term memory.

    Science.gov (United States)

    Le Barillier, Léa; Léger, Lucienne; Luppi, Pierre-Hervé; Fort, Patrice; Malleret, Gaël; Salin, Paul-Antoine

    2015-11-01

    The cognitive role of melanin-concentrating hormone (MCH) neurons, a neuronal population located in the mammalian postero-lateral hypothalamus sending projections to all cortical areas, remains poorly understood. Mainly activated during paradoxical sleep (PS), MCH neurons have been implicated in sleep regulation. The genetic deletion of the only known MCH receptor in rodent leads to an impairment of hippocampal dependent forms of memory and to an alteration of hippocampal long-term synaptic plasticity. By using MCH/ataxin3 mice, a genetic model characterized by a selective deletion of MCH neurons in the adult, we investigated the role of MCH neurons in hippocampal synaptic plasticity and hippocampal-dependent forms of memory. MCH/ataxin3 mice exhibited a deficit in the early part of both long-term potentiation and depression in the CA1 area of the hippocampus. Post-tetanic potentiation (PTP) was diminished while synaptic depression induced by repetitive stimulation was enhanced suggesting an alteration of pre-synaptic forms of short-term plasticity in these mice. Behaviorally, MCH/ataxin3 mice spent more time and showed a higher level of hesitation as compared to their controls in performing a short-term memory T-maze task, displayed retardation in acquiring a reference memory task in a Morris water maze, and showed a habituation deficit in an open field task. Deletion of MCH neurons could thus alter spatial short-term memory by impairing short-term plasticity in the hippocampus. Altogether, these findings could provide a cellular mechanism by which PS may facilitate memory encoding. Via MCH neuron activation, PS could prepare the day's learning by increasing and modulating short-term synaptic plasticity in the hippocampus. © 2015 Wiley Periodicals, Inc.

  17. Beyond the sticker price: including and excluding time in comparing food prices.

    Science.gov (United States)

    Yang, Yanliang; Davis, George C; Muth, Mary K

    2015-07-01

    An ongoing debate in the literature is how to measure the price of food. Most analyses have not considered the value of time in measuring the price of food. Whether or not the value of time is included in measuring the price of a food may have important implications for classifying foods based on their relative cost. The purpose of this article is to compare prices that exclude time (time-exclusive price) with prices that include time (time-inclusive price) for 2 types of home foods: home foods using basic ingredients (home recipes) vs. home foods using more processed ingredients (processed recipes). The time-inclusive and time-exclusive prices are compared to determine whether the time-exclusive prices in isolation may mislead in drawing inferences regarding the relative prices of foods. We calculated the time-exclusive price and time-inclusive price of 100 home recipes and 143 processed recipes and then categorized them into 5 standard food groups: grains, proteins, vegetables, fruit, and dairy. We then examined the relation between the time-exclusive prices and the time-inclusive prices and dietary recommendations. For any food group, the processed food time-inclusive price was always less than the home recipe time-inclusive price, even if the processed food's time-exclusive price was more expensive. Time-inclusive prices for home recipes were especially higher for the more time-intensive food groups, such as grains, vegetables, and fruit, which are generally underconsumed relative to the guidelines. Focusing only on the sticker price of a food and ignoring the time cost may lead to different conclusions about relative prices and policy recommendations than when the time cost is included. © 2015 American Society for Nutrition.

  18. A novel peak detection approach with chemical noise removal using short-time FFT for prOTOF MS data.

    Science.gov (United States)

    Zhang, Shuqin; Wang, Honghui; Zhou, Xiaobo; Hoehn, Gerard T; DeGraba, Thomas J; Gonzales, Denise A; Suffredini, Anthony F; Ching, Wai-Ki; Ng, Michael K; Wong, Stephen T C

    2009-08-01

    Peak detection is a pivotal first step in biomarker discovery from MS data and can significantly influence the results of downstream data analysis steps. We developed a novel automatic peak detection method for prOTOF MS data, which does not require a priori knowledge of protein masses. Random noise is removed by an undecimated wavelet transform and chemical noise is attenuated by an adaptive short-time discrete Fourier transform. Isotopic peaks corresponding to a single protein are combined by extracting an envelope over them. Depending on the S/N, the desired peaks in each individual spectrum are detected and those with the highest intensity among their peak clusters are recorded. The common peaks among all the spectra are identified by choosing an appropriate cut-off threshold in the complete linkage hierarchical clustering. To remove the 1 Da shifting of the peaks, the peak corresponding to the same protein is determined as the detected peak with the largest number among its neighborhood. We validated this method using a data set of serial peptide and protein calibration standards. Compared with MoverZ program, our new method detects more peaks and significantly enhances S/N of the peak after the chemical noise removal. We then successfully applied this method to a data set from prOTOF MS spectra of albumin and albumin-bound proteins from serum samples of 59 patients with carotid artery disease compared to vascular disease-free patients to detect peaks with S/N> or =2. Our method is easily implemented and is highly effective to define peaks that will be used for disease classification or to highlight potential biomarkers.

  19. Thermal sterilization of heat-sensitive products using high-temperature short-time sterilization.

    Science.gov (United States)

    Mann, A; Kiefer, M; Leuenberger, H

    2001-03-01

    High-temperature short-time (HTST) sterilization with a continuous-flow sterilizer, developed for this study, was evaluated. The evaluation was performed with respect to (a) the chemical degradation of two heat-sensitive drugs in HTST range (140-160 degrees C) and (b) the microbiological effect of HTST sterilization. Degradation kinetics of two heat-sensitive drugs showed that a high peak temperature sterilization process resulted in less chemical degradation for the same microbiological effect than a low peak temperature process. Both drugs investigated could be sterilized with acceptable degradation at HTST conditions. For the evaluation of the microbiological effect, Bacillus stearothermophilus ATCC 7953 spores were used as indicator bacteria. Indicator spore kinetics (D(T), z value, k, and E(a)), were determined in the HTST range. A comparison between the Bigelow model (z value concept) and the Arrhenius model, used to describe the temperature coefficient of the microbial inactivation, demonstrated that the Bigelow model is more accurate in prediction of D(T) values in the HTST range. The temperature coefficient decreased with increasing temperature. The influence of Ca(2+) ions and pH value on the heat resistance of the indicator spores, which is known under typical sterilization conditions, did not change under HTST conditions.

  20. Measurement of short bunches

    International Nuclear Information System (INIS)

    Wang, D.X.

    1996-01-01

    In recent years, there has been increasing interest in short electron bunches for different applications such as short wavelength FELs, linear colliders, and advanced accelerators such as laser or plasma wakefield accelerators. One would like to meet various requirements such as high peak current, low momentum spread, high luminosity, small ratio of bunch length to plasma wavelength, and accurate timing. Meanwhile, recent development and advances in RF photoinjectors and various bunching schemes make it possible to generate very short electron bunches. Measuring the longitudinal profile and monitoring bunch length are critical to understand the bunching process and longitudinal beam dynamics, and to commission and operate such short bunch machines. In this paper, several commonly used measurement techniques for subpicosecond bunches and their relative advantages and disadvantages are discussed. As examples, bunch length related measurements at Jefferson Lab are presented. At Jefferson Lab, bunch lengths as short as 84 fs have been systematically measured using a zero-phasing technique. A highly sensitive Coherent Synchrotron Radiation (CSR) detector has been developed to noninvasively monitor bunch length for low charge bunches. Phase transfer function measurements provide a means of correcting RF phase drifts and reproducing RF phases to within a couple of tenths of a degree. The measurement results are in excellent agreement with simulations. A comprehensive bunch length control scheme is presented. (author)

  1. Measurement of short bunches

    International Nuclear Information System (INIS)

    Wang, D.X.

    1996-01-01

    In recent years, there has been increasing interest in short electron bunches for different applications such as short wavelength FELs, linear colliders, and advanced accelerators such as laser or plasma wakefield accelerators. One would like to meet various requirements such as high peak current, low momentum spread, high luminosity, small ratio of bunch length to plasma wavelength, and accurate timing. Meanwhile, recent development and advances in RF photoinjectors and various bunching schemes make it possible to generate very short electron bunches. Measuring the longitudinal profile and monitoring bunch length are critical to understand the bunching process and longitudinal beam dynamics, and to commission and operate such short bunch machines. In this paper, several commonly used measurement techniques for subpicosecond bunches and their relative advantages and disadvantages are discussed. As examples, bunch length related measurements at Jefferson lab are presented. At Jefferson Lab, bunch lengths s short as 84 fs have been systematically measured using a zero-phasing technique. A highly sensitive Coherent Synchrotron Radiation (CSR) detector has been developed to noninvasively monitor bunch length for low charge bunches. Phase transfer function measurements provide a means of correcting RF phase drifts and reproducing RF phases to within a couple of tenths of a degree. The measurement results are in excellent agreement with simulations. A comprehensive bunch length control scheme is presented

  2. Shorts due to diagnostic leads

    International Nuclear Information System (INIS)

    Ellis, J.F.; Lubell, M.S.; Pillsbury, R.D.; Shen, S.S.; Thome, R.J.; Walstrom, P.L.

    1985-01-01

    The superconducting toroidal field coils that are being tested in the Large Coil Test Facility (LCTF) are heavily instrumented. General Electric coil, a lead wire of an internal sensor became shorted across an estimated three or four turns of the pancake winding. This short occurred during the final stages of the winding fabrication and was not accessible for repair. Resistance, voltage gradient, and transient voltage decay measurements were performed to characterize the short and the magnetic damping of the large steel bobbin and outer structural ring. The 32-gage wire causing the short was estimated to be about 10 cm long, with a resistance of 55 mΩ. As a safety measure, we decided to burn out the shorted wire at room temperature before installing the coil in LCTF. Tests were made to determine the energy needed to vaporize a small wire. Computer calculations indicated that within the voltage limits set for the coil, it was not feasible to burn out the wire by rapidly dumping the coil from a low-current dc charge-up. We accomplished the burnout by applying 800 V at 3.25 A, and 60 Hz for about 1 s. Transient voltage decay measurements made after the burnout and compared with those made before the attempt confirmed that the short had indeed been opened

  3. Short-Term Interferential Transabdominal Electrical Stimulation Did Not Change Oral-Rectal Transit Time in Piglets.

    Science.gov (United States)

    Tan, Andre Y F; Sourial, Magdy; Hutson, John M; Southwell, Bridget R

    2018-03-02

    Transcutaneous electrical stimulation (TES) using interferential current (IFC) is a new therapeutic treatment for constipation. Clinical studies show that TES-IFC for 3-6 months improves colonic transit, but it is not clear if short-term stimulation affects transit or the effect requires longer to develop. The aim of this study was to determine if TES-IFC for only four days affects oral-rectal transit time in healthy pigs. Twenty-two 4-5-week old large white female piglets had transit studies during week 4 and week 5 by placing a capsule containing 18 radiopaque plastic markers in the esophagus under anesthetic followed by x-rays at 6, 30, 54, and 78 hours. Animals were randomly assigned to active or control groups. The active group received TES for 30 min daily for four days. Interferential current was applied through four electrodes (4 × 4 cm), with two para-spinal just below the last rib and two on the belly at the same level. Stimulation was at 4000 Hz and 4080-4160 Hz with currents crossing through the abdominal cavity. Whole bowel transit times ranged from 7.7 to 72.2 hours, stomach transit from transit time from 5 to 53 hours. Transit times were the same for the control (median 28.4 hours) and TES-IFC (23.0 hours) groups in the prestimulation and stimulation weeks (control 23.0, TES-IFC 19.8 hours) with no change within or between groups. Four days of half-hour TES-IFC daily in healthy 5-week-old piglets did not change oral-rectal transit time. © 2018 International Neuromodulation Society.

  4. Implementing high-temperature short-time media treatment in commercial-scale cell culture manufacturing processes.

    Science.gov (United States)

    Pohlscheidt, Michael; Charaniya, Salim; Kulenovic, Fikret; Corrales, Mahalia; Shiratori, Masaru; Bourret, Justin; Meier, Steven; Fallon, Eric; Kiss, Robert

    2014-04-01

    The production of therapeutic proteins by mammalian cell culture is complex and sets high requirements for process, facility, and equipment design, as well as rigorous regulatory and quality standards. One particular point of concern and significant risk to supply chain is the susceptibility to contamination such as bacteria, fungi, mycoplasma, and viruses. Several technologies have been developed to create barriers for these agents to enter the process, e.g. filtration, UV inactivation, and temperature inactivation. However, if not implemented during development of the manufacturing process, these types of process changes can have significant impact on process performance if not managed appropriately. This article describes the implementation of the high-temperature short-time (HTST) treatment of cell culture media as an additional safety barrier against adventitious agents during the transfer of a large-scale commercial cell culture manufacturing process. The necessary steps and experiments, as well as subsequent results during qualification runs and routine manufacturing, are shown.

  5. Time dependent analysis of assay comparability: a novel approach to understand intra- and inter-site variability over time

    Science.gov (United States)

    Winiwarter, Susanne; Middleton, Brian; Jones, Barry; Courtney, Paul; Lindmark, Bo; Page, Ken M.; Clark, Alan; Landqvist, Claire

    2015-09-01

    We demonstrate here a novel use of statistical tools to study intra- and inter-site assay variability of five early drug metabolism and pharmacokinetics in vitro assays over time. Firstly, a tool for process control is presented. It shows the overall assay variability but allows also the following of changes due to assay adjustments and can additionally highlight other, potentially unexpected variations. Secondly, we define the minimum discriminatory difference/ratio to support projects to understand how experimental values measured at different sites at a given time can be compared. Such discriminatory values are calculated for 3 month periods and followed over time for each assay. Again assay modifications, especially assay harmonization efforts, can be noted. Both the process control tool and the variability estimates are based on the results of control compounds tested every time an assay is run. Variability estimates for a limited set of project compounds were computed as well and found to be comparable. This analysis reinforces the need to consider assay variability in decision making, compound ranking and in silico modeling.

  6. High-voltage short-fall pulse generator

    International Nuclear Information System (INIS)

    Dolbilov, G.V.; Fateev, A.A.; Petrov, V.A.

    1986-01-01

    Powerful high-voltage pulses with short fall times and relatively low afterpulse amplitude are required for the deflection systems of accelerators. A generator is described that provides, into a 75-ohm load, a voltage pulse of up to 100 kV with a fall time of less than 1 nsec and a relative afterpulse amplitude of less than or equal to 15%. The generator employs a short-circuited ferrite-filled line in which shock waves are formed. A magnetic section is used to increase power. The switch is a TGI1-2500/50 thyratron. The main causes of afterpulses and methods for reducing their amplitude are examined

  7. Inferring interdependencies from short time series

    Indian Academy of Sciences (India)

    Abstract. Complex networks provide an invaluable framework for the study of interlinked dynamical systems. In many cases, such networks are constructed from observed time series by first estimating the ...... does not quantify causal relations (unlike IOTA, or .... Africa_map_regions.svg, which is under public domain.

  8. Phonemes as short time cognitive components

    DEFF Research Database (Denmark)

    Feng, Ling; Hansen, Lars Kai

    2006-01-01

    are the smallest contrastive unit in the sound system of a language. Generalizable components were found deriving from phonemes based on homomorphic filtering features with basic time scale (20 msec). We sparsified the features based on energy as a preprocessing means to eliminate the intrinsic noise. Independent...

  9. Making historic loss data comparable over time and place

    Science.gov (United States)

    Eichner, Jan; Steuer, Markus; Löw, Petra

    2017-04-01

    When utilizing historic loss data for present day risk assessment, it is necessary to make the data comparable over time and place. To achieve this, the assessment of costs from natural hazard events requires consistent and homogeneous methodologies for loss estimation as well as a robust treatment of loss data to estimate and/or reduce distorting effects due to a temporal bias in the reporting of small-scale loss events. Here we introduce Munich Re's NatCatSERVICE loss database and present a novel methodology of peril-specific normalization of the historic losses (to account for socio-economic growth of assets over time), and we introduce a metric of severity classification (called CatClass) that allows for a global comparison of impact severity across countries of different stages of economic development.

  10. Short time series analysis of Didymosphenia geminata blooming in the Oreti River, New Zealand

    Science.gov (United States)

    Garcia, T.; Kilroy, C.; Larned, S.; Packman, A. I.; Kumar, P.

    2010-12-01

    The mat-forming diatom Didymosphenia geminata was introduced to New Zealand in 2004, and subsequently spread to many rivers on the south island. D geminata mats are exceptionally dense and thick. Extensive blooms of this introduced organism have substantially modified the benthic environment in many New Zealand rivers, but the factors that contribute to D. geminata blooming are not well understood. We synthesized a sequence of observations of D. geminata areal coverage and thickness to examine physical and chemical controls on the growth and persistence of D germinata. We analyzed the best available time series on the distribution of this organism in New Zealand, observations in the Oreti River every 15 days spanning April 2006 to May 2007. During this period, mean D. geminata coverage of the river bed was ~52% and the mean mat thickness was ~6 mm. Relationships between time-series observations of D. geminata and 13 different physical and chemical variables were analyzed using linear and nonlinear methods. Areal cover and thickness of D geminata mats were found to be influenced by both slow and fast dynamic processes. The spread of the organism, in terms of % cover, was highly correlated with conductivity, ammonium, nitrate, dissolved oxygen, and total nitrogen with short time lags (fast dynamics). Moreover, water clarity, cloud cover, and flow were highly correlated with % cover with long time lags, indicating that these conditions exert long-term control on D. geminata growth. Areal coverage and thickness were found to be highly correlated, but the variables associated with slow and fast dynamics of these two measures were not identical. The variables found to be highly correlated with D. germinata thickness and represented fast dynamics were temperature, dissolved oxygen, conductivity, nitrate, and total nitrogen. Additionally, the variables influencing the slow dynamics of D. germinata thickness were flow, water clarity, turbidity and total phosphorous.

  11. Experience from the transportation of irradiated WWER-440 fuel assemblies at the Kozloduy NPP site after a short cooling time

    International Nuclear Information System (INIS)

    Stoyanova, I.; Kamenov, A.; Byrzev, L.; Christoskov, I.

    2003-01-01

    Results from the analysis and experimental verification of the radiation and shielding characteristics of non-standard loading patterns of the VSPOT transport cask used for transportation of irradiated fuel assemblies after a short cooling time (120 180 days) on the site of the Kozloduy NPP are presented. An additional safety criterion related to the introduced modifications to the standard procedure of using the transport cask is formulated and discussed (Authors)

  12. Metabolite concentrations in supraventricular white matter from teenage to early old age: A short echo time {sup 1}H magnetic resonance spectroscopy (MRS) study

    Energy Technology Data Exchange (ETDEWEB)

    Raininko, Raili [Dept. of Radiology, Uppsala Univ., Uppsala (Sweden)], e-mail: raili.raininko@radiol.uu.se; Mattsson, Peter [Dept. of Neuroscience, Neurology, Uppsala Univ., Uppsala (Sweden)

    2010-04-15

    Background: Age- and sex-related changes of metabolites in healthy adult brains have been examined with different {sup 1}H magnetic resonance spectroscopy (MRS) methods in varying populations, and with differing results. A long repetition time and short echo time technique reduces quantification errors due to T1 and T2 relaxation effects and makes it possible to measure metabolites with short T2 relaxation times. Purpose: To examine the effect of age on the metabolite concentrations measured by 1H MRS in normal supraventricular white matter using a long repetition time (TR) and a short echo time (TE). Material and Methods: Supraventricular white matter of 57 healthy subjects (25 women, 32 men), aged 13 to 72 years, was examined with a single-voxel MRS at 1.5T using a TR of 6000 ms and a TE of 22 ms. Tissue water was used as a reference in quantification. Results: Myoinositol increased slightly and total N-acetyl aspartate (NAA) decreased slightly with increasing age. Glutamine/glutamate complex (Glx) showed U-shaped age dependence, with highest concentrations in the youngest and oldest subjects. No significant age dependence was found in total choline and total creatine. No gender differences were found. Macromolecule/ lipid (ML) fractions were reliably measurable only in 36/57 or even fewer subjects and showed very large deviations. Conclusion: The concentrations of several metabolites in cerebral supraventricular white matter are age dependent on 1H MRS, even in young and middle-aged people, and age dependency can be nonlinear. Each 1H MRS study of the brain should therefore take age into account, whereas sex does not appear to be so important. The use of macromolecule and lipid evaluations is compromised by less successful quantification and large variations in healthy people.

  13. Evaluation of intracranial neoplasia and noninfectious meningoencephalitis in dogs by use of short echo time, single voxel proton magnetic resonance spectroscopy at 3.0 Tesla.

    Science.gov (United States)

    Carrera, Inés; Richter, Henning; Beckmann, Katrin; Meier, Dieter; Dennler, Matthias; Kircher, Patrick R

    2016-05-01

    OBJECTIVE To investigate metabolite concentrations of the brains of dogs with intracranial neoplasia or noninfectious meningoencephalitis by use of short echo time, single voxel proton magnetic resonance spectroscopy ((1)H MRS) at 3.0 T. ANIMALS 29 dogs with intracranial lesions (14 with neoplasia [3 oligodendromas, 3 glioblastomas multiformes, 3 astrocytomas, 2 lymphomas, and 3 meningiomas] and 15 is with noninfectious meningoencephalitis) and 10 healthy control dogs. PROCEDURES Short echo time, single voxel (1)H-MRS at 3.0 T was performed on neoplastic and noninfectious inflammatory intracranial lesions identified with conventional MRI. Metabolites of interest included N-acetyl aspartate (NAA), total choline, creatine, myoinositol, the glutamine-glutamate complex (Glx), glutathione, taurine, lactate, and lipids. Data were analyzed with postprocessing fitting algorithm software. Metabolite concentrations relative to brain water content were calculated and compared with results for the healthy control dogs, which had been previously evaluated with the same (1)H MRS technique. RESULTS NAA, creatine, and Glx concentrations were reduced in the brains of dogs with neoplasia and noninfectious meningoencephalitis, whereas choline concentration was increased. Concentrations of these metabolites differed significantly between dogs with neoplasia and dogs with noninfectious meningoencephalitis. Concentrations of NAA, creatine, and Glx were significantly lower in dogs with neoplasia, whereas the concentration of choline was significantly higher in dogs with neoplasia. Lipids were predominantly found in dogs with high-grade intra-axial neoplasia, meningioma, and necrotizing meningoencephalitis. A high concentration of taurine was found in 10 of 15 dogs with noninfectious meningoencephalitis. CONCLUSIONS AND CLINICAL RELEVANCE (1)H MRS provided additional metabolic information about intracranial neoplasia and noninfectious meningoencephalitis in dogs.

  14. New use of global warming potentials to compare cumulative and short-lived climate pollutants

    Science.gov (United States)

    Allen, Myles R.; Fuglestvedt, Jan S.; Shine, Keith P.; Reisinger, Andy; Pierrehumbert, Raymond T.; Forster, Piers M.

    2016-08-01

    Parties to the United Nations Framework Convention on Climate Change (UNFCCC) have requested guidance on common greenhouse gas metrics in accounting for Nationally determined contributions (NDCs) to emission reductions. Metric choice can affect the relative emphasis placed on reductions of `cumulative climate pollutants' such as carbon dioxide versus `short-lived climate pollutants' (SLCPs), including methane and black carbon. Here we show that the widely used 100-year global warming potential (GWP100) effectively measures the relative impact of both cumulative pollutants and SLCPs on realized warming 20-40 years after the time of emission. If the overall goal of climate policy is to limit peak warming, GWP100 therefore overstates the importance of current SLCP emissions unless stringent and immediate reductions of all climate pollutants result in temperatures nearing their peak soon after mid-century, which may be necessary to limit warming to ``well below 2 °C'' (ref. ). The GWP100 can be used to approximately equate a one-off pulse emission of a cumulative pollutant and an indefinitely sustained change in the rate of emission of an SLCP. The climate implications of traditional CO2-equivalent targets are ambiguous unless contributions from cumulative pollutants and SLCPs are specified separately.

  15. Etiology of short stature in children

    International Nuclear Information System (INIS)

    Sultan, M.; Afzal, M.; Ali, S.

    2008-01-01

    To determine the causes of short stature in children with special emphasis on growth hormone deficiency. Two hundred and fourteen children (140 boys and 74 girls), ranging from 02 to 15 years presenting with short stature were studied. Height and weight were plotted on appropriate growth charts and centiles determined. Relevant hematological and biochemical investigations including thyroid profile were done. Bone age was determined in all cases. Growth hormone axis was investigated after excluding other causes. Karyotyping was done in selected cases. Data was analyzed by SPSS 10.0 by descriptive statistics. Mean values were compared using t-test. In this study, the five most common etiological factors in order of frequency were Constitutional Growth Delay (CGD), Familial Short Stature (FSS), malnutrition, coeliac disease and Growth Hormone Deficiency (GHD). In 37.4% of patients, the study revealed normal variants of growth - CGD, FSS or combination of both, 46.7% cases had nonendocrinological and 15.9% had endocrinological etiology. CGD (22.1%) in males and FSS (27%) in females were the most common etiology. GHD was found in 6.1% children and it comprised 38.2% of all endocrinological causes. Children with height falling below 0.4th centile were more likely to have a pathological short stature (79.2%) compared to 39.3% whose height was below 3rd centile but above 0.4th centile (p<0.05). CGD and FSS are most common causes of short stature in boys and girls respectively, whereas, GHD is a relatively uncommon etiology. (author)

  16. Short Pulse Laser Applications Design

    International Nuclear Information System (INIS)

    Town, R.J.; Clark, D.S.; Kemp, A.J.; Lasinski, B.F.; Tabak, M.

    2008-01-01

    We are applying our recently developed, LDRD-funded computational simulation tool to optimize and develop applications of Fast Ignition (FI) for stockpile stewardship. This report summarizes the work performed during a one-year exploratory research LDRD to develop FI point designs for the National Ignition Facility (NIF). These results were sufficiently encouraging to propose successfully a strategic initiative LDRD to design and perform the definitive FI experiment on the NIF. Ignition experiments on the National Ignition Facility (NIF) will begin in 2010 using the central hot spot (CHS) approach, which relies on the simultaneous compression and ignition of a spherical fuel capsule. Unlike this approach, the fast ignition (FI) method separates fuel compression from the ignition phase. In the compression phase, a laser such as NIF is used to implode a shell either directly, or by x rays generated from the hohlraum wall, to form a compact dense (∼300 g/cm 3 ) fuel mass with an areal density of ∼3.0 g/cm 2 . To ignite such a fuel assembly requires depositing ∼20kJ into a ∼35 (micro)m spot delivered in a short time compared to the fuel disassembly time (∼20ps). This energy is delivered during the ignition phase by relativistic electrons generated by the interaction of an ultra-short high-intensity laser. The main advantages of FI over the CHS approach are higher gain, a lower ignition threshold, and a relaxation of the stringent symmetry requirements required by the CHS approach. There is worldwide interest in FI and its associated science. Major experimental facilities are being constructed which will enable 'proof of principle' tests of FI in integrated subignition experiments, most notably the OMEGA-EP facility at the University of Rochester's Laboratory of Laser Energetics and the FIREX facility at Osaka University in Japan. Also, scientists in the European Union have recently proposed the construction of a new FI facility, called HiPER, designed to

  17. [THE APPLICATION OF SHORT-TERM EFFICIENCY ANALYSIS IN DIAGNOSING OCCUPATIONAL VOICE DISORDERS].

    Science.gov (United States)

    Niebudek-Bogusz, Ewa; Just, Marcin; Tyc, Michał; Wiktorowicz, Justyna; Morawska, Joanna; Śliwińska-Kowalska, Mariola

    2015-01-01

    An objective determination of the range of vocal efficiency is rather difficult. The aim of the study was to assess the possibility of application of short-term acoustic efficiency analysis in diagnosing occupational voice disorders. The study covered 98 people (87 women and 11 men) diagnosed with occupational dysphonia throuigh videostroboscopic examination. The control group comprised 100 people (81 women and 19 men) with normal voices. The short-term acoustic analysis was carried out by means of DiagnoScope software, including classical parameters (Jitter group, Shimmer group and the assessment of noise degree NHR), as well as new short-term efficiency parameters determined in a short time period during sustained phonation of the vowel "a." The results were then compared. Results: The values of all the examined classical parameters were considerably higher in the study group of pathological voices than in the control group of normal voices (p = 0.00). The aerodynamic parameter, maximum phonation time, was significantly shorter by over 0.5 s in the study group than in the control group. The majority of the acoustic efficiency parameters were also considerably worse in the study group of subjects with occupational dysphonia than in the control group (p = 0.00). Moreover, the correlation between the efficiency parameters and most of the classical acoustic parameters in the study group implies that for the voices with occupational pathology the decreased efficiency of the vocal apparatus is reflected in the acoustic voice structure. Effliciency parameters determined during short-term acoustic analysis can be an objective indicator of the decreased phonatory function of the larnx, useful in diagnosing occupational vocal pathology.

  18. Diagnostic Accuracy of Growth Rate in Differentiating Etiologies of Short Stature in Children

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Alaei

    2016-08-01

    Full Text Available Background  Short stature is a manifestation of a wide variety of conditions that some of which may be amenable to timely treatment and a suboptimal growth rate may be an early marker pointing to the cause of growth retardation. This study was conducted to evaluate the diagnostic utility of growth rate in differential diagnosis of children with short stature. Materials and Methods All children between the ages of 2 and 18 years who visited in pediatric endocrinology clinic in a five years period were recruited in a prospective cohort study. Children with standing height Results One hundred forty three patients fulfilled the inclusion criteria. Mean follow up period was 14.4±10.9 months. Etiologies of short stature were: constitutional growth delay (CGD 46.9%, familial short stature (FSS 28.7%, hypothyroidism 4.2%, growth hormone deficiency (GHD 4.2% and miscellaneous causes in 16% of patients.  Mean Z- score for children with constitutional growth delay was -2.3±0.69, in familial short stature was -2.3±0.65 and for other condition was -2.7±1.49. There was a meaningful statistical correlation between growth rate and etiology of short stature (P0.05. Conclusion There was significant difference in growth rate between children with constitutional growth delay and familial short stature in comparing to short stature due to endocrine problem and other etiologies. Assessment of growth rate has some utility in diagnosing the etiology of short stature.

  19. In Search of Decay in Verbal Short-Term Memory

    Science.gov (United States)

    Berman, Marc G.; Jonides, John; Lewis, Richard L.

    2009-01-01

    Is forgetting in the short term due to decay with the mere passage of time, interference from other memoranda, or both? Past research on short-term memory has revealed some evidence for decay and a plethora of evidence showing that short-term memory is worsened by interference. However, none of these studies has directly contrasted decay and…

  20. NVU dynamics. II. Comparing to four other dynamics

    DEFF Research Database (Denmark)

    Ingebrigtsen, Trond; Toxværd, Søren; Schrøder, Thomas

    2011-01-01

    -potential-energy hypersurface. Here, simulations of NVU dynamics are compared to results for four other dynamics, both deterministic and stochastic. First, NVU dynamics is compared to the standard energy-conserving Newtonian NVE dynamics by simulations of the Kob-Andersen binary Lennard-Jones liquid, its WCA version (i.......e., with cut-off's at the pair potential minima), and the Lennard-Jones Gaussian liquid. We find identical results for all quantities probed: radial distribution functions, incoherent intermediate scattering functions, and mean-square displacement as function of time. Arguments are presented...... on the constant-potential-energy hypersurface, and to Nos-Hoover NVT dynamics. If time is scaled for the two stochastic dynamics to make single-particle diffusion constants identical to that of NVE dynamics, the simulations show that all five dynamics are equivalent at low temperatures except at short times....

  1. The "Chaos Theory" and nonlinear dynamics in heart rate variability analysis: does it work in short-time series in patients with coronary heart disease?

    Science.gov (United States)

    Krstacic, Goran; Krstacic, Antonija; Smalcelj, Anton; Milicic, Davor; Jembrek-Gostovic, Mirjana

    2007-04-01

    Dynamic analysis techniques may quantify abnormalities in heart rate variability (HRV) based on nonlinear and fractal analysis (chaos theory). The article emphasizes clinical and prognostic significance of dynamic changes in short-time series applied on patients with coronary heart disease (CHD) during the exercise electrocardiograph (ECG) test. The subjects were included in the series after complete cardiovascular diagnostic data. Series of R-R and ST-T intervals were obtained from exercise ECG data after sampling digitally. The range rescaled analysis method determined the fractal dimension of the intervals. To quantify fractal long-range correlation's properties of heart rate variability, the detrended fluctuation analysis technique was used. Approximate entropy (ApEn) was applied to quantify the regularity and complexity of time series, as well as unpredictability of fluctuations in time series. It was found that the short-term fractal scaling exponent (alpha(1)) is significantly lower in patients with CHD (0.93 +/- 0.07 vs 1.09 +/- 0.04; P chaos theory during the exercise ECG test point out the multifractal time series in CHD patients who loss normal fractal characteristics and regularity in HRV. Nonlinear analysis technique may complement traditional ECG analysis.

  2. Unsupervised land cover change detection: meaningful sequential time series analysis

    CSIR Research Space (South Africa)

    Salmon, BP

    2011-06-01

    Full Text Available An automated land cover change detection method is proposed that uses coarse spatial resolution hyper-temporal earth observation satellite time series data. The study compared three different unsupervised clustering approaches that operate on short...

  3. Enhancement and stabilization of plasma using collinear long-short double-pulse laser-induced breakdown spectroscopy

    Science.gov (United States)

    Cui, Minchao; Deguchi, Yoshihiro; Wang, Zhenzhen; Fujita, Yuki; Liu, Renwei; Shiou, Fang-Jung; Zhao, Shengdun

    2018-04-01

    A collinear long-short dual-pulse laser-induced breakdown spectroscopy (DP-LIBS) method was employed to enhance and stabilize the laser-induced plasma from steel sample. The long-pulse-width laser beam with the pulse width of 60 μs was generated by a Nd: YAG laser which was operated at FR (free running) mode. The comparative experiments were carried out between single pulse LIBS (SP-LIBS) and long-short DP-LIBS. The recorded results showed that the emission intensities and the temperature of plasma were enhanced by long-short DP-LIBS. The plasma images showed that the plasma was bigger and had a longer lifetime in long-short DP-LIBS situation. Through the calculation of time-resolved plasma temperature and intensity ratio, it can be concluded that the plasma was stabilized by the long-pulse-width laser beam. The long-short DP-LIBS method also generated the stable plasma condition from the samples with different initial temperatures, which overcame the difficulties of LIBS in the online measurement for steel production line.

  4. Evaluation of Short Term Memory Span Function In Children

    OpenAIRE

    Barış ERGÜL; Arzu ALTIN YAVUZ; Ebru GÜNDOĞAN AŞIK

    2016-01-01

    Although details of the information encoded in the short-term memory where it is stored temporarily be recorded in the working memory in the next stage. Repeating the information mentally makes it remain in memory for a long time. Studies investigating the relationship between short-term memory and reading skills that are carried out to examine the relationship between short-term memory processes and reading comprehension. In this study information coming to short-term memory and the factors ...

  5. Diagnostic time in digital pathology: A comparative study on 400 cases

    Directory of Open Access Journals (Sweden)

    Aleksandar Vodovnik

    2016-01-01

    Full Text Available Background: Numerous validation studies in digital pathology confirmed its value as a diagnostic tool. However, a longer time to diagnosis than traditional microscopy has been seen as a significant barrier to the routine use of digital pathology. As a part of our validation study, we compared a digital and microscopic diagnostic time in the routine diagnostic setting. Materials and Methods: One senior staff pathologist reported 400 consecutive cases in histology, nongynecological, and fine needle aspiration cytology (20 sessions, 20 cases/session, over 4 weeks. Complex, difficult, and rare cases were excluded from the study to reduce the bias. A primary diagnosis was digital, followed by traditional microscopy, 6 months later, with only request forms available for both. Microscopic slides were scanned at ×20, digital images accessed through the fully integrated laboratory information management system (LIMS and viewed in the image viewer on double 23” displays. A median broadband speed was 299 Mbps. A diagnostic time was measured from the point slides were made available to the point diagnosis was made or additional investigations were deemed necessary, recorded independently in minutes/session and compared. Results: A digital diagnostic time was 1841 and microscopic 1956 min; digital being shorter than microscopic in 13 sessions. Four sessions with shorter microscopic diagnostic time included more cases requiring extensive use of magnifications over ×20. Diagnostic time was similar in three sessions. Conclusions: A diagnostic time in digital pathology can be shorter than traditional microscopy in the routine diagnostic setting, with adequate and stable network speeds, fully integrated LIMS and double displays as default parameters. This also related to better ergonomics, larger viewing field, and absence of physical slide handling, with effects on both diagnostic and nondiagnostic time. Differences with previous studies included a design

  6. Error analysis of short term wind power prediction models

    International Nuclear Information System (INIS)

    De Giorgi, Maria Grazia; Ficarella, Antonio; Tarantino, Marco

    2011-01-01

    The integration of wind farms in power networks has become an important problem. This is because the electricity produced cannot be preserved because of the high cost of storage and electricity production must follow market demand. Short-long-range wind forecasting over different lengths/periods of time is becoming an important process for the management of wind farms. Time series modelling of wind speeds is based upon the valid assumption that all the causative factors are implicitly accounted for in the sequence of occurrence of the process itself. Hence time series modelling is equivalent to physical modelling. Auto Regressive Moving Average (ARMA) models, which perform a linear mapping between inputs and outputs, and Artificial Neural Networks (ANNs) and Adaptive Neuro-Fuzzy Inference Systems (ANFIS), which perform a non-linear mapping, provide a robust approach to wind power prediction. In this work, these models are developed in order to forecast power production of a wind farm with three wind turbines, using real load data and comparing different time prediction periods. This comparative analysis takes in the first time, various forecasting methods, time horizons and a deep performance analysis focused upon the normalised mean error and the statistical distribution hereof in order to evaluate error distribution within a narrower curve and therefore forecasting methods whereby it is more improbable to make errors in prediction. (author)

  7. Error analysis of short term wind power prediction models

    Energy Technology Data Exchange (ETDEWEB)

    De Giorgi, Maria Grazia; Ficarella, Antonio; Tarantino, Marco [Dipartimento di Ingegneria dell' Innovazione, Universita del Salento, Via per Monteroni, 73100 Lecce (Italy)

    2011-04-15

    The integration of wind farms in power networks has become an important problem. This is because the electricity produced cannot be preserved because of the high cost of storage and electricity production must follow market demand. Short-long-range wind forecasting over different lengths/periods of time is becoming an important process for the management of wind farms. Time series modelling of wind speeds is based upon the valid assumption that all the causative factors are implicitly accounted for in the sequence of occurrence of the process itself. Hence time series modelling is equivalent to physical modelling. Auto Regressive Moving Average (ARMA) models, which perform a linear mapping between inputs and outputs, and Artificial Neural Networks (ANNs) and Adaptive Neuro-Fuzzy Inference Systems (ANFIS), which perform a non-linear mapping, provide a robust approach to wind power prediction. In this work, these models are developed in order to forecast power production of a wind farm with three wind turbines, using real load data and comparing different time prediction periods. This comparative analysis takes in the first time, various forecasting methods, time horizons and a deep performance analysis focused upon the normalised mean error and the statistical distribution hereof in order to evaluate error distribution within a narrower curve and therefore forecasting methods whereby it is more improbable to make errors in prediction. (author)

  8. Mouse Activity across Time Scales: Fractal Scenarios

    Science.gov (United States)

    Lima, G. Z. dos Santos; Lobão-Soares, B.; do Nascimento, G. C.; França, Arthur S. C.; Muratori, L.; Ribeiro, S.; Corso, G.

    2014-01-01

    In this work we devise a classification of mouse activity patterns based on accelerometer data using Detrended Fluctuation Analysis. We use two characteristic mouse behavioural states as benchmarks in this study: waking in free activity and slow-wave sleep (SWS). In both situations we find roughly the same pattern: for short time intervals we observe high correlation in activity - a typical 1/f complex pattern - while for large time intervals there is anti-correlation. High correlation of short intervals ( to : waking state and to : SWS) is related to highly coordinated muscle activity. In the waking state we associate high correlation both to muscle activity and to mouse stereotyped movements (grooming, waking, etc.). On the other side, the observed anti-correlation over large time scales ( to : waking state and to : SWS) during SWS appears related to a feedback autonomic response. The transition from correlated regime at short scales to an anti-correlated regime at large scales during SWS is given by the respiratory cycle interval, while during the waking state this transition occurs at the time scale corresponding to the duration of the stereotyped mouse movements. Furthermore, we find that the waking state is characterized by longer time scales than SWS and by a softer transition from correlation to anti-correlation. Moreover, this soft transition in the waking state encompass a behavioural time scale window that gives rise to a multifractal pattern. We believe that the observed multifractality in mouse activity is formed by the integration of several stereotyped movements each one with a characteristic time correlation. Finally, we compare scaling properties of body acceleration fluctuation time series during sleep and wake periods for healthy mice. Interestingly, differences between sleep and wake in the scaling exponents are comparable to previous works regarding human heartbeat. Complementarily, the nature of these sleep-wake dynamics could lead to a better

  9. Time Perspective and Identity Formation: Short-Term Longitudinal Dynamics in College Students

    Science.gov (United States)

    Luyckx, Koen; Lens, Willy; Smits, Ilse; Goossens, Luc

    2010-01-01

    Planning for the future and developing a personalized identity are conceived of as important developmental tasks that adolescents and emerging adults are confronted with on the pathway to adulthood. The present study set out to examine whether both tasks develop in tandem by using a short-term longitudinal dataset consisting of 371 college…

  10. Short-Time Structural Stability of Compressible Vortex Sheets with Surface Tension

    Science.gov (United States)

    Stevens, Ben

    2016-11-01

    Assume we start with an initial vortex-sheet configuration which consists of two inviscid fluids with density bounded below flowing smoothly past each other, where a strictly positive fixed coefficient of surface tension produces a surface tension force across the common interface, balanced by the pressure jump. We model the fluids by the compressible Euler equations in three space dimensions with a very general equation of state relating the pressure, entropy and density such that the sound speed is positive. We prove that, for a short time, there exists a unique solution of the equations with the same structure. The mathematical approach consists of introducing a carefully chosen artificial viscosity-type regularisation which allows one to linearise the system so as to obtain a collection of transport equations for the entropy, pressure and curl together with a parabolic-type equation for the velocity which becomes fairly standard after rotating the velocity according to the interface normal. We prove a high order energy estimate for the non-linear equations that is independent of the artificial viscosity parameter which allows us to send it to zero. This approach loosely follows that introduced by Shkoller et al. in the setting of a compressible liquid-vacuum interface. Although already considered by Coutand et al. [10] and Lindblad [17], we also make some brief comments on the case of a compressible liquid-vacuum interface, which is obtained from the vortex sheets problem by replacing one of the fluids by vacuum, where it is possible to obtain a structural stability result even without surface tension.

  11. A time-to-amplitude converter with constant fraction timing discriminators for short time interval measurements

    International Nuclear Information System (INIS)

    Kostamovaara, J.; Myllylae, R.

    1985-01-01

    The construction and the performance of a time-to-amplitude converter equipped with constant fraction discriminators is described. The TAC consists of digital and analog parts which are constructed on two printed circuit boards, both of which are located in a single width NIM module. The dead time of the TAC for a start pulse which is not followed by a stop pulse within the time range of the device (proportional100 ns) is only proportional100 ns, which enables one to avoid counting rate saturation even with a high random input signal rate. The differential and integral nonlinearities of the TAC are better than +-1.5% and 0.05%, respectively. The resolution for input timing pulses of constant shape is 20 ps (fwhm), and less than 10 ps (fwhm) with a modification in the digital part. The walk error of the constant fraction timing discriminators is presented and various parameters affecting it are discussed. The effect of the various disturbances in linearity caused by the fast ECL logic and their minimization are also discussed. The time-to-amplitude converter has been used in positron lifetime studies and for laser range finding. (orig.)

  12. Role of short-acting nitroglycerin in the management of ischemic heart disease

    Directory of Open Access Journals (Sweden)

    Boden WE

    2015-08-01

    Full Text Available William E Boden,1–3 Santosh K Padala,1–3 Katherine P Cabral,4 Ivo R Buschmann,5 Mandeep S Sidhu1–31Department of Medicine, Division of Cardiology, Albany Medical College, 2Department of Medicine, Division of Cardiology, Albany Stratton Veterans Affairs Medical Center, 3Department of Medicine, Division of Cardiology, Albany Medical Center, 4Department of Pharmacy, Albany College Pharmacy and Health Sciences, Albany, NY, USA; 5Department of Angiology, Medical University of Brandenburg & Charité, Berlin, GermanyAbstract: Nitroglycerin is the oldest and most commonly prescribed short-acting anti-anginal agent; however, despite its long history of therapeutic usage, patient and health care provider education regarding the clinical benefits of the short-acting formulations in patients with angina remains under-appreciated. Nitrates predominantly induce vasodilation in large capacitance blood vessels, increase epicardial coronary arterial diameter and coronary collateral blood flow, and impair platelet aggregation. The potential for the prophylactic effect of short-acting nitrates remains an under-appreciated part of optimal medical therapy to reduce angina and decrease myocardial ischemia, thereby enhancing the quality of life. Short-acting nitroglycerin, administered either as a sublingual tablet or spray, can complement anti-anginal therapy as part of optimal medical therapy in patients with refractory and recurrent angina either with or without myocardial revascularization, and is most commonly used to provide rapid therapeutic relief of acute recurrent angina attacks. When administered prophylactically, both formulations increase angina-free walking time on treadmill testing, abolish or delay ST segment depression, and increase exercise tolerance. The sublingual spray formulation provides several clinical advantages compared to tablet formulations, including a lower incidence of headache and superiority to the sublingual tablet in terms of

  13. Comparative response time and fault logging with a PLC and supervisory software and a standalone unit developed for recording

    International Nuclear Information System (INIS)

    Baldaconi, Ricardo H.; Costa, Fabio E. da

    2017-01-01

    The Cobalt-60 irradiator of IPEN / CNEN, a category IV facility, has a security system for inter locking doors or exposure of radioactive sources made simultaneously by a programmable logic controller (PLC) model S7-200 from Siemens and a relay logic. From a set of information, both systems work together opening doors or exposing the sources. All incoming and outgoing information are sent serially via EIA232 communication to a personal computer with Windows® platform for a supervisory program which provides the monitoring of the entire process by a synoptic table on the computer screen and is also intended to keep records of all events on the computer's hard drive. A deficiency was found for the process of sending events via serial communication (EIA232) from PLC to the supervisory program. When failure occurred in a very short time, the PLC always took the right decision, but the registration process that had to go through the Windows® timeshare lost the information. In the previous work developed a standalone electronics unit connected to the inputs and outputs of the security system, fully optocoupled to avoid any interference to the security system that records each event on a memory card. In this work, for checking the unit developed record time ability, transients incoming signals for simulating failures, were injected at security system inputs and the response time of security system, supervisory program and the autonomous unity were measured and compared. (author)

  14. Comparative response time and fault logging with a PLC and supervisory software and a standalone unit developed for recording

    Energy Technology Data Exchange (ETDEWEB)

    Baldaconi, Ricardo H., E-mail: ricardohovacker@hotmail.com [Escola Senai Roberto Simonsen, Educação e Tecnologia, Sao Paulo, SP (Brazil); Costa, Fabio E. da, E-mail: fecosta@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    The Cobalt-60 irradiator of IPEN / CNEN, a category IV facility, has a security system for inter locking doors or exposure of radioactive sources made simultaneously by a programmable logic controller (PLC) model S7-200 from Siemens and a relay logic. From a set of information, both systems work together opening doors or exposing the sources. All incoming and outgoing information are sent serially via EIA232 communication to a personal computer with Windows® platform for a supervisory program which provides the monitoring of the entire process by a synoptic table on the computer screen and is also intended to keep records of all events on the computer's hard drive. A deficiency was found for the process of sending events via serial communication (EIA232) from PLC to the supervisory program. When failure occurred in a very short time, the PLC always took the right decision, but the registration process that had to go through the Windows® timeshare lost the information. In the previous work developed a standalone electronics unit connected to the inputs and outputs of the security system, fully optocoupled to avoid any interference to the security system that records each event on a memory card. In this work, for checking the unit developed record time ability, transients incoming signals for simulating failures, were injected at security system inputs and the response time of security system, supervisory program and the autonomous unity were measured and compared. (author)

  15. A direct comparison of short-term audiomotor and visuomotor memory.

    Science.gov (United States)

    Ward, Amanda M; Loucks, Torrey M; Ofori, Edward; Sosnoff, Jacob J

    2014-04-01

    Audiomotor and visuomotor short-term memory are required for an important variety of skilled movements but have not been compared in a direct manner previously. Audiomotor memory capacity might be greater to accommodate auditory goals that are less directly related to movement outcome than for visually guided tasks. Subjects produced continuous isometric force with the right index finger under auditory and visual feedback. During the first 10 s of each trial, subjects received continuous auditory or visual feedback. For the following 15 s, feedback was removed but the force had to be maintained accurately. An internal effort condition was included to test memory capacity in the same manner but without external feedback. Similar decay times of ~5-6 s were found for vision and audition but the decay time for internal effort was ~4 s. External feedback thus provides an advantage in maintaining a force level after feedback removal, but may not exclude some contribution from a sense of effort. Short-term memory capacity appears longer than certain previous reports but there may not be strong distinctions in capacity across different sensory modalities, at least for isometric force.

  16. Comparative Genomics of Recent Shiga Toxin-Producing Escherichia coli O104:H4: Short-Term Evolution of an Emerging Pathogen

    Science.gov (United States)

    Grad, Yonatan H.; Godfrey, Paul; Cerquiera, Gustavo C.; Mariani-Kurkdjian, Patricia; Gouali, Malika; Bingen, Edouard; Shea, Terrence P.; Haas, Brian J.; Griggs, Allison; Young, Sarah; Zeng, Qiandong; Lipsitch, Marc; Waldor, Matthew K.; Weill, François-Xavier; Wortman, Jennifer R.; Hanage, William P.

    2013-01-01

    ABSTRACT The large outbreak of diarrhea and hemolytic uremic syndrome (HUS) caused by Shiga toxin-producing Escherichia coli O104:H4 in Europe from May to July 2011 highlighted the potential of a rarely identified E. coli serogroup to cause severe disease. Prior to the outbreak, there were very few reports of disease caused by this pathogen and thus little known of its diversity and evolution. The identification of cases of HUS caused by E. coli O104:H4 in France and Turkey after the outbreak and with no clear epidemiological links raises questions about whether these sporadic cases are derived from the outbreak. Here, we report genome sequences of five independent isolates from these cases and results of a comparative analysis with historical and 2011 outbreak isolates. These analyses revealed that the five isolates are not derived from the outbreak strain; however, they are more closely related to the outbreak strain and each other than to isolates identified prior to the 2011 outbreak. Over the short time scale represented by these closely related organisms, the majority of genome variation is found within their mobile genetic elements: none of the nine O104:H4 isolates compared here contain the same set of plasmids, and their prophages and genomic islands also differ. Moreover, the presence of closely related HUS-associated E. coli O104:H4 isolates supports the contention that fully virulent O104:H4 isolates are widespread and emphasizes the possibility of future food-borne E. coli O104:H4 outbreaks. PMID:23341549

  17. Short term exposure to cooking fumes and pulmonary function

    Directory of Open Access Journals (Sweden)

    Qvenild Torgunn

    2009-05-01

    Full Text Available Abstract Background Exposure to cooking fumes may have different deleterious effects on the respiratory system. The aim of this study was to look at possible effects from inhalation of cooking fumes on pulmonary function. Methods Two groups of 12 healthy volunteers (A and B stayed in a model kitchen for two and four hours respectively, and were monitored with spirometry four times during twenty four hours, on one occasion without any exposure, and on another with exposure to controlled levels of cooking fumes. Results The change in spirometric values during the day with exposure to cooking fumes, were not statistically significantly different from the changes during the day without exposure, with the exception of forced expiratory time (FET. The change in FET from entering the kitchen until six hours later, was significantly prolonged between the exposed and the unexposed day with a 15.7% increase on the exposed day, compared to a 3.2% decrease during the unexposed day (p-value = 0.03. The same tendency could be seen for FET measurements done immediately after the exposure and on the next morning, but this was not statistically significant. Conclusion In our experimental setting, there seems to be minor short term spirometric effects, mainly affecting FET, from short term exposure to cooking fumes.

  18. Comparisons and Selections of Features and Classifiers for Short Text Classification

    Science.gov (United States)

    Wang, Ye; Zhou, Zhi; Jin, Shan; Liu, Debin; Lu, Mi

    2017-10-01

    Short text is considerably different from traditional long text documents due to its shortness and conciseness, which somehow hinders the applications of conventional machine learning and data mining algorithms in short text classification. According to traditional artificial intelligence methods, we divide short text classification into three steps, namely preprocessing, feature selection and classifier comparison. In this paper, we have illustrated step-by-step how we approach our goals. Specifically, in feature selection, we compared the performance and robustness of the four methods of one-hot encoding, tf-idf weighting, word2vec and paragraph2vec, and in the classification part, we deliberately chose and compared Naive Bayes, Logistic Regression, Support Vector Machine, K-nearest Neighbor and Decision Tree as our classifiers. Then, we compared and analysed the classifiers horizontally with each other and vertically with feature selections. Regarding the datasets, we crawled more than 400,000 short text files from Shanghai and Shenzhen Stock Exchanges and manually labeled them into two classes, the big and the small. There are eight labels in the big class, and 59 labels in the small class.

  19. Prevention of hospital payment errors and implications for case management: a study of nine hospitals with a high proportion of short-term admissions over time.

    Science.gov (United States)

    Hightower, Rebecca E

    2008-01-01

    Since the publication of the first analysis of Medicare payment error rates in 1998, the Office of Inspector General and the Centers for Medicare & Medicaid Services have focused resources on Medicare payment error prevention programs, now referred to as the Hospital Payment Monitoring Program. The purpose of the Hospital Payment Monitoring Program is to educate providers of Medicare Part A services in strategies to improve medical record documentation and decrease the potential for payment errors through appropriate claims completion. Although the payment error rates by state (and dollars paid in error) have decreased significantly, opportunities for improvement remain as demonstrated in this study of nine hospitals with a high proportion of short-term admissions over time. Previous studies by the Quality Improvement Organization had focused on inpatient stays of 1 day or less, a primary target due to the large amount of Medicare dollars spent on these admissions. Random review of Louisiana Medicare admissions revealed persistent medical record documentation and process issues regardless of length of stay as well as the opportunity for significant future savings to the Medicare Trust Fund. The purpose of this study was to determine whether opportunities for improvement in reduction of payment error continue to exist for inpatient admissions of greater than 1 day, despite focused education provided by Louisiana Health Care Review, the Louisiana Medicare Quality Improvement Organization, from 1999 to 2005, and to work individually with the nine selected hospitals to assist them in reducing the number of unnecessary short-term admissions and billing errors in each hospital by a minimum of 50% by the end of the study period. Inpatient Short-Term Acute Care Hospitals. A sample of claims for short-term stays (defined as an inpatient admission with a length of stay of 3 days or less excluding deaths, interim bills for those still a patient and those who left against

  20. Short time administration of antirheumatic drugs - Methotrexate as a strong inhibitor of osteoblast's proliferation in vitro

    Directory of Open Access Journals (Sweden)

    Annussek Tobias

    2012-09-01

    Full Text Available Abstract Introduction Due to increasing use of disease modifying antirheumatic drugs (DMARDs as first line therapy in rheumatic diseases, dental and maxillofacial practitioner should be aware of drug related adverse events. Especially effects on bone-metabolism and its cells are discussed controversially. Therefore we investigate the in vitro effect of short time administration of low dose methotrexate (MTX on osteoblasts as essential part of bone remodelling cells. Methods Primary bovine osteoblasts (OBs were incubated with various concentrations of MTX, related to tissue concentrations, over a period of fourteen days by using a previously established standard protocol. The effect on cell proliferation as well as mitochondrial activity was assessed by using 3-(4, 5-dimethylthiazol-2-yl 2, 5-diphenyltetrazolium bromide (MTT assay, imaging and counting of living cells. Additionally, immunostaining of extracellular matrix proteins was used to survey osteogenic differentiation. Results All methods indicate a strong inhibition of osteoblast`s proliferation by short time administration of low dose MTX within therapeutically relevant concentrations of 1 to 1000nM, without affecting cell differentiation of middle-stage differentiated OBs in general. More over a significant decrease of cell numbers and mitochondrial activity was found at these MTX concentrations. The most sensitive method seems to be the MTT-assay. MTX-concentration of 0,01nM and concentrations below had no inhibitory effects anymore. Conclusion Even low dose methotrexate acts as a potent inhibitor of osteoblast’s proliferation and mitochondrial metabolism in vitro, without affecting main differentiation of pre-differentiated osteoblasts. These results suggest possible negative effects of DMARDs concerning bone healing and for example osseointegration of dental implants. Especially the specifics of the jaw bone with its high vascularisation and physiological high tissue metabolism

  1. Ghrelin plasma levels in patients with idiopathic short stature.

    Science.gov (United States)

    Iñiguez, Germán; Román, Rossana; Youlton, Ronald; Cassorla, Fernando; Mericq, Verónica

    2011-02-01

    Novel molecular insights have suggested that ghrelin may be involved in the pathogenesis of some forms of short stature. Recently, growth hormone secretagogue receptor (GHSR) mutations that segregate with short stature have been reported. To study plasma ghrelin levels in prepubertal patients with idiopathic short stature (ISS). Fasting total plasma ghrelin levels (radioimmunoassay) in 41 prepubertal patients with ISS (18 females, age 7.9 ± 0.5 years) compared with 42 age- and sex-matched controls (27 females, age 8.0 ± 0.3 years) with normal height. In a subset of 28 patients, the ghrelin receptor was sequenced. ISS patients exhibited a higher level of ghrelin (1,458 ± 137 vs. 935 ± 55 pg/ml, p ghrelin levels greater than +2 SDS compared to controls. These patients did not differ in height, BMI or IGF-I SDS compared to ISS patients with ghrelin levels within the normal range. Molecular analysis of GHSR did not show any mutations, but showed some polymorphisms. These results suggest that in ISS patients, short stature does not appear to be frequently caused by abnormalities in ghrelin signaling. Copyright © 2010 S. Karger AG, Basel.

  2. Fast Weight Long Short-Term Memory

    OpenAIRE

    Keller, T. Anderson; Sridhar, Sharath Nittur; Wang, Xin

    2018-01-01

    Associative memory using fast weights is a short-term memory mechanism that substantially improves the memory capacity and time scale of recurrent neural networks (RNNs). As recent studies introduced fast weights only to regular RNNs, it is unknown whether fast weight memory is beneficial to gated RNNs. In this work, we report a significant synergy between long short-term memory (LSTM) networks and fast weight associative memories. We show that this combination, in learning associative retrie...

  3. Analysing the protective potential of padded soccer goalkeeper shorts.

    Science.gov (United States)

    Schmitt, K U; Nusser, M; Derler, S; Boesiger, P

    2010-05-01

    In this study, the potential of currently available padded soccer goalkeeper shorts to prevent hip injuries sustained in side jumps was investigated. Within the scope of this study, a survey among professional and amateur goalkeepers, trainers and the medical staff was performed. In addition, commercially available shorts were impact-tested using an artificial hip model. The results were compared with requirements established for hip protectors for elderly. The results of the survey found that contusions and abrasions were observed most often for all players. Fractures and arthritis were only reported by amateur players, whereas bursitis was more frequently observed by professional players. Amateurs have a significantly higher risk of injury than professional players, and the higher injury risk during training is significantly higher compared with the injury risk during a match. No difference of the injury risk was found between goalkeepers wearing padded shorts and those who did not. Impact tests indicated a wide range of performance of the currently available products. The padded shorts generally reduce impact forces, but mostly perform poorly. Only shorts that were made of visco-elastic foam fulfilled the basic requirements requested for hip protectors for elderly. The quality of most of the currently available goalkeeper shorts needs to be improved to effectively prevent hip injury sustained in side jumps.

  4. The history of time a very short introduction

    CERN Document Server

    Holford-Strevens, Leofranc

    2005-01-01

    Leofranc Holford-Strevens explores time measurement and the organisation of time into hours, days, months and years using a range of fascinating examples from Ancient Rome and Julius Caesar's Leap Year, to the 1920s' project for a fixed Easter. - ;Why do we measure time in the way that we do? Why is a week seven days long? At what point did minutes and seconds come into being? Why are some calendars lunar and some solar? The organisation of time into hours, days, months and years seems immutable and universal, but is actually far more artificial than most people realise. The French Revolution

  5. Modelling the short term interest with stochastic differential equation in continuous time: linear versus non-linear mode

    OpenAIRE

    2014-01-01

    M.Com. (Financial Economics) Recently, there has been a growth in the bond market. This growth has brought with it an ever-increasing volume and range of interest rate depended derivative products known as interest rate derivatives. Amongst the variables used in pricing these derivative products is the short-term interest rate. A numbers of short-term interest rate models that are used to fit the short-term interest rate exist. Therefore, understanding the features characterised by various...

  6. A new methodology involving stable isotope tracer to compare short- and long- term selenium mobility in soils

    Science.gov (United States)

    Tolu, Julie; Thiry, Yves; Potin-gautier, Martine; Le hécho, Isabelle; Bueno, Maïté

    2013-04-01

    Selenium is an element of environmental concern given its dual beneficial and toxic character to animal and human health. Its radioactive isotope 79Se, a fission product of 235U, is considered critical in safety assessment of nuclear waste repositories in case of leakage and hypothetical soil contamination. Therefore, Se species transformations and interactions with soil components have to be clearly understood to predict its dispersion in the biosphere (e.g., accumulation in soils, migration to waters, transfer to living organisms). While natural Se interactions with soils run over centuries to millennia time scales, transformations and partitioning are generally studied with short-term experiments (often inferior to 1 month) after Se addition. The influence of slower, long-term processes involved in Se speciation and mobility in soils is thus not properly accounted for. We tested if using ambient Se would be relevant for long-term risk assessment while added Se would be more representative of short-term contamination impact. For that purpose, we developed a new methodology to trace the differential reactivity of ambient and spiked Se at trace level (µg kg-1) in soils. It combined the use of a stable isotopically enriched tracer with our previous published analytical method based on specific extractions and HPLC-ICP-MS to determine trace Se species partition in different soil phases. Given that soil extracts contains very high concentrations of various elements interfering Se (e.g., Fe, Cl, Br), the ICP-MS parameters and mathematical corrections were optimized to cope with such interferences. Following optimization, three correct and accurate (<2%) isotope ratios were obtained with 77Se, 78Se, 80Se and 82Se. The optimized method was then applied to an arable and a forest soil submitted to an aging process (drying/wetting cycles) during three months, to which 77Se(IV) was previously added. The results showed that ambient Se was at steady state in terms of water

  7. Decay uncovered in nonverbal short-term memory.

    Science.gov (United States)

    Mercer, Tom; McKeown, Denis

    2014-02-01

    Decay theory posits that memory traces gradually fade away over the passage of time unless they are actively rehearsed. Much recent work exploring verbal short-term memory has challenged this theory, but there does appear to be evidence for trace decay in nonverbal auditory short-term memory. Numerous discrimination studies have reported a performance decline as the interval separating two tones is increased, consistent with a decay process. However, most of this tone comparison research can be explained in other ways, without reference to decay, and these alternative accounts were tested in the present study. In Experiment 1, signals were employed toward the end of extended retention intervals to ensure that listeners were alert to the presence and frequency content of the memoranda. In Experiment 2, a mask stimulus was employed in an attempt to distinguish between a highly detailed sensory trace and a longer-lasting short-term memory, and the distinctiveness of the stimuli was varied. Despite these precautions, slow-acting trace decay was observed. It therefore appears that the mere passage of time can lead to forgetting in some forms of short-term memory.

  8. Effect of high-temperature, short-time (HTST) pasteurization on milk containing low numbers of Mycobacterium paratuberculosis.

    Science.gov (United States)

    Grant, I R; Ball, H J; Rowe, M T

    1998-02-01

    The efficacy of high-temperature, short-time (HTST) pasteurization (72 degrees C/15 s) when low numbers (HTST pasteurization using laboratory pasteurizing units. Ten bovine strains of Myco. paratuberculosis were tested in triplicate. Culture in BACTEC Middlebrook 12B radiometric medium detected acid-fast survivors in 14.8% and 10% of HTST-pasteurized milk samples at the 10(3) and 10(2) cfu ml-1 inoculum levels, respectively, whereas conventional culture on Herrold's egg yolk medium containing mycobactin J detected acid-fast survivors in only 3.7% and 6.7% of the same milk samples. IS900-based PCR confirmed that these acid-fast survivors were Myco. paratuberculosis. No viable Myco. paratuberculosis were isolated from HTST-pasteurized milk initially containing either 10 cfu ml-1 or 10 cfu 50 ml-1.

  9. Evaluation of anaerobic digestion processes for short sludge-age waste activated sludge combined with anammox treatment of digestate liquor.

    Science.gov (United States)

    Ge, Huoqing; Batstone, Damien; Keller, Jurg

    2016-01-01

    The need to reduce energy input and enhance energy recovery from wastewater is driving renewed interest in high-rate activated sludge treatment (i.e. short hydraulic and solids retention times (HRT and SRT, respectively)). This process generates short SRT activated sludge stream, which should be highly degradable. However, the evaluation of anaerobic digestion of short SRT sludge has been limited. This paper assesses anaerobic digestion of short SRT sludge digestion derived from meat processing wastewater under thermophilic and mesophilic conditions. The thermophilic digestion system (55°C) achieved 60 and 68% volatile solids destruction at 8 day and 10 day HRT, respectively, compared with 50% in the mesophilic digestion system (35°C, 10 day HRT). The digestion effluents from the thermophilic (8-10 day HRT) and mesophilic systems were stable, as assessed by residual methane potentials. The ammonia rich sludge dewatering liquor was effectively treated by a batch anammox process, which exhibited comparable nitrogen removal rate as the tests using a control synthetic ammonia solution, indicating that the dewatering liquor did not have inhibiting/toxic effects on the anammox activity.

  10. The application of short-term efficiency analysis in diagnosing occupational voice disorders

    Directory of Open Access Journals (Sweden)

    Ewa Niebudek-Bogusz

    2015-06-01

    Full Text Available Background: An objective determination of the range of vocal efficiency is rather difficult. The aim of the study was to assess the possibility of application of short-term acoustic efficiency analysis in diagnosing occupational voice disorders. Material and Methods: The study covered 98 people (87 women and 11 men diagnosed with occupational dysphonia through videostroboscopic examination. The control group comprised 100 people (81 women and 19 men with normal voices. The short-term acoustic analysis was carried out by means of DiagnoScope software, including classical parameters (Jitter group, Shimmer group and the assessment of noise degree NHR, as well as new short-term efficiency parameters determined in a short time period during sustained phonation of the vowel “a.” The results were then compared. Results: The values of all the examined classical parameters were considerably higher in the study group of pathological voices than in the control group of normal voices (p = 0.00. The aerodynamic parameter, maximum phonation time, was significantly shorter by over 0.5 s in the study group than in the control group. The majority of the acoustic efficiency parameters were also considerably worse in the study group of subjects with occupational dysphonia than in the control group (p = 0.00. Moreover, the correlation between the efficiency parameters and most of the classical acoustic parameters in the study group implies that for the voices with occupational pathology the decreased efficiency of the vocal apparatus is reflected in the acoustic voice structure. Conclusions: Efficiency parameters determined during short-term acoustic analysis can be an objective indicator of the decreased phonatory function of the larynx, useful in diagnosing occupational vocal pathology. Med Pr 2015;66(2:225–234

  11. 77 FR 48175 - Comment Request for Information Collection for Applications, Grants and Administration of Short...

    Science.gov (United States)

    2012-08-13

    ... Collection for Applications, Grants and Administration of Short Time Compensation (STC) Provisions, Extension... act'') contains Subtitle D, Short-Time Compensation Program, also known as the ``Layoff Prevention Act..., or wish to initiate a new program in, a layoff aversion program known as short time compensation (STC...

  12. Short-term effects of a nicotine-free e-cigarette compared to a traditional cigarette in smokers and non-smokers.

    Science.gov (United States)

    Ferrari, Marco; Zanasi, Alessandro; Nardi, Elena; Morselli Labate, Antonio Maria; Ceriana, Piero; Balestrino, Antonella; Pisani, Lara; Corcione, Nadia; Nava, Stefano

    2015-10-12

    A few studies have assessed the short-term effects of low-dose nicotine e-cigarettes, while data about nicotine-free e-cigarettes (NF e-cigarettes) are scanty. Concerns have been expressed about the use of NF e-cigarettes, because of the high concentrations of propylene glycol and other compounds in the e-cigarette vapor. This laboratory-based study was aimed to compare the effects of ad libitum use of a NF e-cigarette or and a traditional cigarette for 5 min in healthy adult smokers (n = 10) and non-smokers (n = 10). The main outcome measures were pulmonary function tests, fraction of exhaled nitric oxide (FeNO) and fractional concentration of carbon monoxide (FeCO) in exhaled breath. The traditional cigarette induced statistically significant increases in FeCO in both smokers and non-smokers, while no significant changes were observed in FeNO. In non-smokers, the traditional cigarette induced a significant decrease from baseline in FEF75 (81 % ± 35 % vs 70.2 % ± 28.2 %, P = 0.013), while in smokers significant decreases were observed in FEF25 (101.3 % ± 16.4 % vs 93.5 % ± 31.7 %, P = 0.037), FEV1 (102.2 % ± 9.5 % vs 98.3 % ± 10 %, P = 0.037) and PEF (109.5 % ± 14.6 % vs 99.2 % ± 17.5 %, P = 0.009). In contrast, the only statistically significant effects induced by the NF e-cigarette in smokers were reductions in FEV1 (102.2 % ± 9.5 % vs 99.5 ± 7.6 %, P = 0.041) and FEF25 (103.4 % ± 16.4 % vs 94.2 % ± 16.2 %, P =  .014). The present study demonstrated that the specific brand of NF e-cigarette utilized did not induce any majoracute effects. In contrast, several studies have shown that both traditional cigarettes and nicotine-containing e-cigarettes have acute effects on lung function. Our study expands on previous observations on the effects of NF e-cigarettes, but also for the first time describes the changes induced by smoking one traditional cigarette in a group of never smokers. The short-term use of the specific brand of NF e-cigarette assessed

  13. Short-term memory for auditory and visual durations: evidence for selective interference effects.

    Science.gov (United States)

    Rattat, Anne-Claire; Picard, Delphine

    2012-01-01

    The present study sought to determine the format in which visual, auditory and auditory-visual durations ranging from 400 to 600 ms are encoded and maintained in short-term memory, using suppression conditions. Participants compared two stimulus durations separated by an interval of 8 s. During this time, they performed either an articulatory suppression task, a visuospatial tracking task or no specific task at all (control condition). The results showed that the articulatory suppression task decreased recognition performance for auditory durations but not for visual or bimodal ones, whereas the visuospatial task decreased recognition performance for visual durations but not for auditory or bimodal ones. These findings support the modality-specific account of short-term memory for durations.

  14. On the transition of short cracks into long fatigue cracks in reactor pressure vessel steels

    Directory of Open Access Journals (Sweden)

    Singh Rajwinder

    2018-01-01

    Full Text Available Short fatigue cracks, having dimension less than 1 mm, propagate at much faster rates (da/dN even at lower stress intensity factor range (da/dN as compared to the threshold stress intensity factor range obtained from long fatigue crack growth studies. These short cracks originate at the sub-grain level and some of them ultimately transit into critical long cracks over time. Therefore, designing the components subjected to fatigue loading merely on the long crack growth data and neglecting the short crack growth behavior can overestimate the component’s life. This aspect of short fatigue cracks become even more critical for materials used for safety critical applications such as reactor pressure vessel (RPV steel in nuclear plants. In this work, the transition behaviour of short fatigue crack gowth into long fatigue crack is studied in SA508 Grade 3 Class I low alloy steel used in RPVs. In-situ characterization of initiation, propagation and transition of short fatigue cracks is performed using fatigue stage for Scanning Electron Microscope (SEM in addition to digital microscopes fitted over a servo-hydraulic fatigue machine and correlated with the microtructural information obtained using electron backscatter diffraction (EBSD. SA508 steel having an upper bainitic microstructure have several microstructural interfaces such as phase and grain boundaries that play a significant role in controlling the short fatigue crack propagation. Specially designed and prepared short fatigue specimens (eletro-polished with varying initial crack lengths of the order of tens of microns are used in this study. The transition of such short initial cracks into long cracks is then tracked to give detailed insight into the role of each phase and phase/grain boundary with an objective of establishing Kitagawa-Takahashi diagram for the given RPV steel. The behavior of the transited long cracks is then compared with the crack propagation behavior obtained using

  15. Superconducting cyclotron magnet coil short

    International Nuclear Information System (INIS)

    Mallory, M.L.; Blosser, H.G.; Clark, D.J.; Launer, H.; Lawton, D.; Miller, P.; Resmini, F.

    1982-01-01

    In February 1981, a short circuit appeared in the superconducting coil of the K500 cyclotron. The short is resistive in character and therefore has no effect on steady state operation of the magnet. The resistance of the short varies, sometimes being below threshold of detection as a heat load on the cooling system and sometimes being significant. The resistance under certain conditions shows approximately cyclic phenomena with time constants in the range of seconds and other approximately cyclic phenomena which correlate with gross operating parameters of the magnet (shifting current from one coil to another at high field and lowering and raising the liquid helium level). A number of diagnostic studies of the short have been made, using 1) an array of flux sensing loops to sense the magnetic effect of the short, 2) voltage comparisons between upper and lower sections of the coil, 3) comparisons of forces in the nine member coil support system and 4) the effect of the short on the thermal charactersitics of the coil. Insulation failure or a metal chip shorting out turns have been explored in some detail but a convincing determination of the exact cause of the short may never be available, (even the extreme step of unwinding the coil having a significant probability that an imperfection with the observed characteristics would pass unnoticed). Analysis of the characteristics of the short indicated that the most serious consequence would be failure of the coils mechanical support system in the event that the magnet was quickly discharged, as in a dump or quench. To deal with this hazard, the support system has been modified by installing solid supports which prevent the coil from moving by an amount sufficient to damage the support system. We have also reexamined the data and calculations used in the original coil design and have made some additional measurements of the properties of the materials (yield strength, friction coefficient, Young's modulus) used in the

  16. How Do Earth-Sized, Short-Period Planets Form?

    Science.gov (United States)

    Kohler, Susanna

    2017-08-01

    day)23 hot Jupiters (larger than 4 times Earths radius and orbital period shorter than 10 days)243 small hot planets (smaller than 4 times Earths radius and orbital period between 1 and 10 days)They then compare the metallicity distributions of these three groups.Back to the Drawing BoardMetallicity distributions of the three statistical samples. The hot-Jupiter hosts (orange) have different distribution than the others; it is weighted more toward higher metallicities. [Winn et al. 2017]Winn and collaborators find that hosts of ultra-short-period planets do not have the same metallicity distribution as hot-Jupiter hosts; the metallicities of hot-Jupiter hosts are significantly higher. The metallicity distributions for hosts of ultra-short-period planets and hosts of small hot planets were statistically indistinguishable, however.These results strongly suggest that the majority of ultra-short-period planets are not the cores of former hot Jupiters. Alternative options include the possibility that they are the cores of smaller planets, such as sub-Neptunes, or that they are the short-period extension of the distribution of close-in, small rocky planets that formed by core accretion.This narrowing of the options for the formation of ultra-short-period planets is certainly intriguing. We can hope to further explore possibilities in the future after the Transiting Exoplanet Survey Satellites (TESS) comes online next year; TESS is expected to discover many more ultra-short-period planets that are too faint for Kepler to detect.CitationJoshua N. Winn et al 2017 AJ 154 60. doi:10.3847/1538-3881/aa7b7c

  17. A New Empirical Model for Short-Term Forecasting of the Broadband Penetration: A Short Research in Greece

    Directory of Open Access Journals (Sweden)

    Salpasaranis Konstantinos

    2011-01-01

    Full Text Available The objective of this paper is to present a short research about the overall broadband penetration in Greece. In this research, a new empirical deterministic model is proposed for the short-term forecast of the cumulative broadband adoption. The fitting performance of the model is compared with some widely used diffusion models for the cumulative adoption of new telecommunication products, namely, Logistic, Gompertz, Flexible Logistic (FLOG, Box-Cox, Richards, and Bass models. The fitting process is done with broadband penetration official data for Greece. In conclusion, comparing these models with the empirical model, it could be argued that the latter yields well enough statistics indicators for fitting and forecasting performance. It also stresses the need for further research and performance analysis of the model in other more mature broadband markets.

  18. A good time to leave?: the sunk time effect in pigeons.

    Science.gov (United States)

    Magalhães, Paula; White, K Geoffrey

    2014-06-01

    Persistence in a losing course of action due to prior investments of time, known as the sunk time effect, has seldom been studied in nonhuman animals. On every trial in the present study, pigeons were required to choose between two response keys. Responses on one key produced food after a short fixed interval (FI) of time on some trials, or on other trials, no food (Extinction) after a longer time. FI and Extinction trials were not differently signaled, were equiprobable, and alternated randomly. Responses on a second Escape key allowed the pigeon to terminate the current trial and start a new one. The optimal behavior was for pigeons to peck the escape key once the duration equivalent to the short FI had elapsed without reward. Durations of the short FI and the longer Extinction schedules were varied over conditions. In some conditions, the pigeons suboptimally responded through the Extinction interval, thus committing the sunk time effect. The absolute duration of the short FI had no effect on the choice between persisting and escaping. Instead, the ratio of FI and Extinction durations determined the likelihood of persistence during extinction. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Across-province standardization and comparative analysis of time-to-care intervals for cancer

    Directory of Open Access Journals (Sweden)

    Nugent Zoann

    2007-10-01

    Full Text Available Abstract Background A set of consistent, standardized definitions of intervals and populations on which to report across provinces is needed to inform the Provincial/Territorial Deputy Ministries of Health on progress of the Ten-Year Plan to Strengthen Health Care. The objectives of this project were to: 1 identify a set of criteria and variables needed to create comparable measures of important time-to-cancer-care intervals that could be applied across provinces and 2 use the measures to compare time-to-care across participating provinces for lung and colorectal cancer patients diagnosed in 2004. Methods A broad-based group of stakeholders from each of the three participating cancer agencies was assembled to identify criteria for time-to-care intervals to standardize, evaluate possible intervals and their corresponding start and end time points, and finalize the selection of intervals to pursue. Inclusion/exclusion criteria were identified for the patient population and the selected time points to reduce potential selection bias. The provincial 2004 colorectal and lung cancer data were used to illustrate across-province comparisons for the selected time-to-care intervals. Results Criteria identified as critical for time-to-care intervals and corresponding start and end points were: 1 relevant to patients, 2 relevant to clinical care, 3 unequivocally defined, and 4 currently captured consistently across cancer agencies. Time from diagnosis to first radiation or chemotherapy treatment and the smaller components, time from diagnosis to first consult with an oncologist and time from first consult to first radiation or chemotherapy treatment, were the only intervals that met all four criteria. Timeliness of care for the intervals evaluated was similar between the provinces for lung cancer patients but significant differences were found for colorectal cancer patients. Conclusion We identified criteria important for selecting time-to-care intervals

  20. Short-Circuit Fault Detection and Classification Using Empirical Wavelet Transform and Local Energy for Electric Transmission Line.

    Science.gov (United States)

    Huang, Nantian; Qi, Jiajin; Li, Fuqing; Yang, Dongfeng; Cai, Guowei; Huang, Guilin; Zheng, Jian; Li, Zhenxin

    2017-09-16

    In order to improve the classification accuracy of recognizing short-circuit faults in electric transmission lines, a novel detection and diagnosis method based on empirical wavelet transform (EWT) and local energy (LE) is proposed. First, EWT is used to deal with the original short-circuit fault signals from photoelectric voltage transformers, before the amplitude modulated-frequency modulated (AM-FM) mode with a compactly supported Fourier spectrum is extracted. Subsequently, the fault occurrence time is detected according to the modulus maxima of intrinsic mode function (IMF₂) from three-phase voltage signals processed by EWT. After this process, the feature vectors are constructed by calculating the LE of the fundamental frequency based on the three-phase voltage signals of one period after the fault occurred. Finally, the classifier based on support vector machine (SVM) which was constructed with the LE feature vectors is used to classify 10 types of short-circuit fault signals. Compared with complementary ensemble empirical mode decomposition with adaptive noise (CEEMDAN) and improved CEEMDAN methods, the new method using EWT has a better ability to present the frequency in time. The difference in the characteristics of the energy distribution in the time domain between different types of short-circuit faults can be presented by the feature vectors of LE. Together, simulation and real signals experiment demonstrate the validity and effectiveness of the new approach.

  1. DTW4Omics: comparing patterns in biological time series.

    Directory of Open Access Journals (Sweden)

    Rachel Cavill

    Full Text Available When studying time courses of biological measurements and comparing these to other measurements eg. gene expression and phenotypic endpoints, the analysis is complicated by the fact that although the associated elements may show the same patterns of behaviour, the changes do not occur simultaneously. In these cases standard correlation-based measures of similarity will fail to find significant associations. Dynamic time warping (DTW is a technique which can be used in these situations to find the optimal match between two time courses, which may then be assessed for its significance. We implement DTW4Omics, a tool for performing DTW in R. This tool extends existing R scripts for DTW making them applicable for "omics" datasets where thousands entities may need to be compared with a range of markers and endpoints. It includes facilities to estimate the significance of the matches between the supplied data, and provides a set of plots to enable the user to easily visualise the output. We illustrate the utility of this approach using a dataset linking the exposure of the colon carcinoma Caco-2 cell line to oxidative stress by hydrogen peroxide (H2O2 and menadione across 9 timepoints and show that on average 85% of the genes found are not obtained from a standard correlation analysis between the genes and the measured phenotypic endpoints. We then show that when we analyse the genes identified by DTW4Omics as significantly associated with a marker for oxidative DNA damage (8-oxodG, through over-representation, an Oxidative Stress pathway is identified as the most over-represented pathway demonstrating that the genes found by DTW4Omics are biologically relevant. In contrast, when the positively correlated genes were similarly analysed, no pathways were found. The tool is implemented as an R Package and is available, along with a user guide from http://web.tgx.unimaas.nl/svn/public/dtw/.

  2. The Genome-Wide DNA Methylation Profile of Peripheral Blood Is Not Systematically Changed by Short-Time Storage at Room Temperature

    Directory of Open Access Journals (Sweden)

    Nicklas Heine Staunstrup

    2017-12-01

    Full Text Available Background: Epigenetic epidemiology has proven an important research discipline in the delineation of diseases of complex etiology. The approach, in such studies, is often to use bio-banked clinical material, however, many such samples were collected for purposes other than epigenetic studies and, thus, potentially not processed and stored appropriately. The Danish National Birth Cohort (DNBC includes more than 100,000 peripheral and umbilical cord blood samples shipped from maternity wards by ordinary mail in EDTA tubes. While this and other similar cohorts hold great promises for DNA methylation studies the potential systematic changes prompted by storage at ambient temperatures have never been assessed on a genome-wide level. Methods and Results: In this study, matched EDTA whole blood samples were stored up to three days at room temperature prior to DNA extraction and methylated DNA immunoprecipitation coupled with deep sequencing (MeDIP-seq. We established that the quality of the MeDIP-seq libraries was high and comparable across samples; and that the methylation profiles did not change systematically during the short-time storage at room temperature. Conclusion: The global DNA methylation profile is stable in whole blood samples stored for up to three days at room temperature in EDTA tubes making genome-wide methylation studies on such material feasible.

  3. Non-linear dynamical classification of short time series of the rössler system in high noise regimes.

    Science.gov (United States)

    Lainscsek, Claudia; Weyhenmeyer, Jonathan; Hernandez, Manuel E; Poizner, Howard; Sejnowski, Terrence J

    2013-01-01

    Time series analysis with delay differential equations (DDEs) reveals non-linear properties of the underlying dynamical system and can serve as a non-linear time-domain classification tool. Here global DDE models were used to analyze short segments of simulated time series from a known dynamical system, the Rössler system, in high noise regimes. In a companion paper, we apply the DDE model developed here to classify short segments of encephalographic (EEG) data recorded from patients with Parkinson's disease and healthy subjects. Nine simulated subjects in each of two distinct classes were generated by varying the bifurcation parameter b and keeping the other two parameters (a and c) of the Rössler system fixed. All choices of b were in the chaotic parameter range. We diluted the simulated data using white noise ranging from 10 to -30 dB signal-to-noise ratios (SNR). Structure selection was supervised by selecting the number of terms, delays, and order of non-linearity of the model DDE model that best linearly separated the two classes of data. The distances d from the linear dividing hyperplane was then used to assess the classification performance by computing the area A' under the ROC curve. The selected model was tested on untrained data using repeated random sub-sampling validation. DDEs were able to accurately distinguish the two dynamical conditions, and moreover, to quantify the changes in the dynamics. There was a significant correlation between the dynamical bifurcation parameter b of the simulated data and the classification parameter d from our analysis. This correlation still held for new simulated subjects with new dynamical parameters selected from each of the two dynamical regimes. Furthermore, the correlation was robust to added noise, being significant even when the noise was greater than the signal. We conclude that DDE models may be used as a generalizable and reliable classification tool for even small segments of noisy data.

  4. Comparison of high pressure and high temperature short time processing on quality of carambola juice during cold storage.

    Science.gov (United States)

    Huang, Hsiao-Wen; Chen, Bang-Yuan; Wang, Chung-Yi

    2018-05-01

    This study validated high hydrostatic pressure processing (HPP) for achieving greater than 5-log reductions of Escherichia coli O157:H7 in carambola juice and determined shelf life of processed juice stored at 4 °C. Carambola juice processed at 600 MPa for 150 s was identified capable of achieving greater than 5.15-log reductions of E. coli O157:H7, and the quality was compared with that of high temperature short time (HTST)-pasteurized juice at 110 °C for 8.6 s. Aerobic, psychrotrophic, E. coli /coliform, and yeasts and moulds in the juice were reduced by HPP or HTST to levels below the minimum detection limit (HTST juices. However, HTST treatment significantly changed the color of juice, while no significant difference was observed between the control and HPP samples. HPP and HTST treatments reduced the total soluble solids in the juice, but maintained higher sucrose, glucose, fructose, and total sugar contents than untreated juice. The total phenolic and ascorbic acid contents were higher in juice treated with HPP than untreated and HTST juice, but there was no significant difference in the flavonoid content. Aroma score analysis showed that HPP had no effect on aroma, maintaining the highest score during cold storage. The results of this study suggest that appropriate HPP conditions can achieve the same microbial safety as HTST, while maintaining the quality and extending the shelf life of carambola juice.

  5. Design spectra development considering short time histories

    International Nuclear Information System (INIS)

    Weiner, E.O.

    1983-01-01

    Two separate programs, MODQKE and MDOF, were written to provide a capability of obtaining equipment spectra from design spectra. MODQKE generates or modifies acceleration histories to conform with design spectra pertaining to, say, a foundation. MDOF is a simple linear modal superposition program that solves for equipment support histories using the design spectra conforming histories as input. Equipment spectra, then, are obtained from the support histories using MODQKE. MODQKE was written to modify or provide new histories with special attention paid to short seismic records. A technique from the open literature was borrowed to generate an initial history that approximates a given response spectrum. Further refinement is done with smoothing cycles in which several correction signals are added to the history in a way that produces a least squares fit between actual and prescribed spectra. Provision is made for history shaping, a baseline correction, and final scaling. MODQKE performance has been demonstrated with seven examples having zero to ten percent damping ratios, and 2.5 seconds to 20 seconds durations and a variety of target spectra. The examples show the program is inexpensive to use. MDOF is a simple modal superposition program. It has no eigensolver, and the user supplies mode shapes, frequencies, and participation factors as input. Floor spectra can be generated from design spectra by using a history from MODQKE that conforms to the design spectrum as input to MDOF. Floor motions from MDOF can be fed back to MODQKE without modification to obtain the floor spectra. A simple example is given to show how equipment mass effects can be incorporated into the MDOF solution. Any transient solution capability can be used to replace MDOF. For example, a direct transient approach may be desirable if both the equipment and floor structures are to be included in the model with different damping fractions. (orig./HP)

  6. Do elite breath-hold divers suffer from mild short-term memory impairments?

    Science.gov (United States)

    Billaut, François; Gueit, Patrice; Faure, Sylvane; Costalat, Guillaume; Lemaître, Frédéric

    2018-03-01

    Repeated apneas are associated with severe hypoxemia that may ultimately lead to loss of consciousness in some breath-hold divers. Despite increasing number of practitioners, the relationship between apnea-induced hypoxia and neurocognitive functions is still poorly understood in the sport of free diving. To shed light onto this phenomenon, we examined the impact of long-term breath-hold diving training on attentional processing, short-term memory, and long-term mnesic and executive functions. Thirty-six men matched for age, height, and weight were separated into the following 3 groups: (i) 12 elite breath-hold divers (EBHD), mean static apnea best time 371 s, 105 months mean apnea experience; (ii) 12 novice breath-hold divers, mean best time 243 s, 8.75 months mean apnea experience; and (iii) 12 physical education students with no breath-hold diving experience; all of these participants performed varied written and computerized neuropsychological tasks. Compared with the 2 other groups, the EBHD group was slower to complete the interference card during a Stroop test (F [1,33] = 4.70, p short-term memory impairments.

  7. [Effect of short-acting combined oral contraceptives on bleeding after induced abortion].

    Science.gov (United States)

    Wang, X F; Zhong, M; Liu, J

    2017-11-07

    Objective: To explore the effect of short-acting combined oral contraceptives on vaginal bleeding after induced abortion. Methods: A total of 726 patients, who had took induced abortion from July 2016 to September 2016 in obstetrics and gynecology outpatient department of Nanfang Hospital, Southern Medical University, were included and divided into the observation group and the control group according to whether they took short-acting combined oral contraceptives after induced abortion, with 312 cases, 414 cases respectively.The vaginal bleeding days, amounts of bleeding, the endometrial thickness 3 weeks later, and whether the patient had menstrual recovery on time were observed and analyzed. Results: The observation group had less bleeding days and amount of bleeding, compared with the control group.69.87% (218/312) patients of the observation group had more than 8mm of endometrial thickness on postoperative day 21, while 61.11% (253/414) of the observation group did, the difference was statistically significant ( P =0.034).90.06% (281/312) patients of the observation group had menstrual recovery on time, while 82.61% (342/414) of the observation group did, the difference was statistically significant ( P =0.004). Conclusion: Short-acting combined oral contraceptives after induced abortion can significantly shorten the vaginal bleeding days, reduce the amount of bleeding, promote endometrial repair and menstrual recovery.There fore, it has important clinical significance and application value.

  8. OUTCOME OF INTERTROCHANTERIC FRACTURES TREATED WITH SHORT FEMORAL NAIL

    Directory of Open Access Journals (Sweden)

    Yadkikar Shriniwas V, Yadkikar Vishnu S, Patel Mayank, Dhruvilkumar Gandhi, Kunkulol Rahul

    2015-07-01

    Full Text Available Aim: To study the functional and anatomical outcome of Inter trochanteric fractures of femur treated with Short femoral nail. Method: This was retrospective study carried out in which 60 patients (50 Male & 10 Female of 5th to 8th decade of life who underwent Short femoral nail fixation for both Stable & unstable Inter Trochanteric fractures. From the records each patient data was assessed for time required for mobilization, average fracture healing time, degree and grade of hip range of movements, complications, anatomical reduction achieved using Short femoral nail fixation. Results: 55 cases achieved Anatomical reduction. Good to Excellent Hip range of Motion was in 55 (90 % cases. Fracture union was seen in all cases. No evidence of Z Effect, AVN of femoral head, Implant failure, Fracture of femoral shaft below the Nail tip was seen in any case, However Reverse Z Effect was seen in 4 & shortening of less than 2 cm was seen in 2 cases, External rotation of 10 degree was seen in1 case. Average fracture Union time was 14 weeks. Conclusion: Short femoral nail appears to be better implant for fixation of both Stable & unstable Inter Trochanteric fractures as it fulfills the biomechanical demands being minimally invasive, less blood loss , it prevents excessive varus collapse at fracture site, produces less stress riser effect below the nail tip, Short operative time, Facilitates early mobilization & functional recovery of patients. But Anatomical fracture reduction & optimal implant placement are absolutely must for better results.

  9. The Effects of Reducing Preparation Time on the Execution of Intentionally Curved Trajectories: Optimization and Geometrical Analysis

    Directory of Open Access Journals (Sweden)

    Dovrat Kohen

    2017-06-01

    Full Text Available When subjects are intentionally preparing a curved trajectory, they are engaged in a time-consuming trajectory planning process that is separate from target selection. To investigate the construction of such a plan, we examined the effect of artificially shortening preparation time on the performance of intentionally curved trajectories using the Timed Response task that enforces initiation of movements prematurely. Fifteen subjects performed obstacle avoidance movements toward one of four targets that were presented 25 or 350 ms before the “go” signal, imposing short and long preparation time conditions with mean values of 170 ms and 493 ms, respectively. While trajectories with short preparation times showed target specificity at their onset, they were significantly more variable and showed larger angular deviations from the lines connecting their initial position and the target, compared to the trajectories with long preparation times. Importantly, the trajectories of the short preparation time movements still reached their end-point targets accurately, with comparable movement durations. We hypothesize that success in the short preparation time condition is a result of an online control mechanism that allows further refinement of the plan during its execution and study this control mechanism with a novel trajectory analysis approach using minimum jerk optimization and geometrical modeling approaches. Results show a later agreement of the short preparation time trajectories with the optimal minimum jerk trajectory, accompanied by a later initiation of a parabolic segment. Both observations are consistent with the existence of an online trajectory planning process.Our results suggest that when preparation time is not sufficiently long, subjects execute a more variable and less optimally prepared initial trajectory and exploit online control mechanisms to refine their actions on the fly.

  10. The Effects of Reducing Preparation Time on the Execution of Intentionally Curved Trajectories: Optimization and Geometrical Analysis

    Science.gov (United States)

    Kohen, Dovrat; Karklinsky, Matan; Meirovitch, Yaron; Flash, Tamar; Shmuelof, Lior

    2017-01-01

    When subjects are intentionally preparing a curved trajectory, they are engaged in a time-consuming trajectory planning process that is separate from target selection. To investigate the construction of such a plan, we examined the effect of artificially shortening preparation time on the performance of intentionally curved trajectories using the Timed Response task that enforces initiation of movements prematurely. Fifteen subjects performed obstacle avoidance movements toward one of four targets that were presented 25 or 350 ms before the “go” signal, imposing short and long preparation time conditions with mean values of 170 ms and 493 ms, respectively. While trajectories with short preparation times showed target specificity at their onset, they were significantly more variable and showed larger angular deviations from the lines connecting their initial position and the target, compared to the trajectories with long preparation times. Importantly, the trajectories of the short preparation time movements still reached their end-point targets accurately, with comparable movement durations. We hypothesize that success in the short preparation time condition is a result of an online control mechanism that allows further refinement of the plan during its execution and study this control mechanism with a novel trajectory analysis approach using minimum jerk optimization and geometrical modeling approaches. Results show a later agreement of the short preparation time trajectories with the optimal minimum jerk trajectory, accompanied by a later initiation of a parabolic segment. Both observations are consistent with the existence of an online trajectory planning process.Our results suggest that when preparation time is not sufficiently long, subjects execute a more variable and less optimally prepared initial trajectory and exploit online control mechanisms to refine their actions on the fly. PMID:28706478

  11. 26 CFR 1.6074-2 - Time for filing declarations by corporations in case of a short taxable year.

    Science.gov (United States)

    2010-04-01

    ...(a) are met before the 1st day of the 9th month of the short taxable year, the declaration shall be filed on or before the 15th day of the 9th month of such short year. In the case of a short taxable year...) Example. The application of the provisions of this paragraph may be illustrated by the following example...

  12. Short Run Profit Maximization in a Convex Analysis Framework

    Directory of Open Access Journals (Sweden)

    Ilko Vrankic

    2017-03-01

    Full Text Available In this article we analyse the short run profit maximization problem in a convex analysis framework. The goal is to apply the results of convex analysis due to unique structure of microeconomic phenomena on the known short run profit maximization problem where the results from convex analysis are deductively applied. In the primal optimization model the technology in the short run is represented by the short run production function and the normalized profit function, which expresses profit in the output units, is derived. In this approach the choice variable is the labour quantity. Alternatively, technology is represented by the real variable cost function, where costs are expressed in the labour units, and the normalized profit function is derived, this time expressing profit in the labour units. The choice variable in this approach is the quantity of production. The emphasis in these two perspectives of the primal approach is given to the first order necessary conditions of both models which are the consequence of enveloping the closed convex set describing technology with its tangents. The dual model includes starting from the normalized profit function and recovering the production function, and alternatively the real variable cost function. In the first perspective of the dual approach the choice variable is the real wage, and in the second it is the real product price expressed in the labour units. It is shown that the change of variables into parameters and parameters into variables leads to both optimization models which give the same system of labour demand and product supply functions and their inverses. By deductively applying the results of convex analysis the comparative statics results are derived describing the firm's behaviour in the short run.

  13. Improvement of the Original Isolation Procedure for Hormone Studies in Short-Time Culture

    Directory of Open Access Journals (Sweden)

    Mukadder Atmaca

    2005-01-01

    Full Text Available Earlier studies indicated that hormone responsiveness of cells and metabolic activity was lost during various of experimental procedure. In the light of this observation, I aimed to investigate to obtain optimal conditions for short time cultured hepatocytes and also to determine the type of test can be used to evaluate suitablity of hepatocytes for hormones studies. During the isolation period 50 IU/ml and 100 IU/ml collagenase were used. Adrenaline (10-6M was used to measure sensitivity of hepatocytes to hormones and glycogenolsis was measured at the end of 2hr incubation period. Adrenaline significantly increased gylcogenolysis (Control: 0.16±0.01 mg/2hr; Adrenaline: 0.30±0.01 mg/2hr only when the 50 IU/ml collagenase was used and the viability of the cells were over 95%. Viability tests were applied to hepatocytes that obtained by using 50 IU collagenase. Cellular glutathione, methylthiazoltetrazolium reduction, lactatedehdrogenase leakage, ATP level measured to determine viability following the attachment and incubation period. No differences were observed at the end of each period.Altogether, the present study indicated that membrane integrity and metabolic function of the hepatocytes can be improved by modifying slightly the original procedure of Reese and Byard.

  14. Intact organism, short-term studies using 11C

    International Nuclear Information System (INIS)

    Spence, R.D.; Sharpe, P.J.H.

    1991-01-01

    Experimental investigation of biochemical pathways and biophysical mechanisms is difficult because in many cases more than one pathway or mechanism is involved. Ideally, a physiological tracer should be used to follow the uptake, transport, and assimilation of materials such as carbon and nitrogen to characterize the movements and mechanisms of physiological processes. Real-time measurements of net photosynthesis and dark respiration of plants have been possible since the development of the infrared gas analyzer (IRGA), allowing the intensive investigation of mechanisms and dynamics of CO 2 assimilation in green plants. Comparable research on the movement of carbon within the plant, however, requires another technique that allows real-time observations of carbon transport. This chapter describes how the short-lived radioisotope 11 C can be used to conduct plant physiological studies that are difficult or impossible to make using other isotopes such as 14 C

  15. SHORT COMMUNICATION: Time measurement device with four femtosecond stability

    Science.gov (United States)

    Panek, Petr; Prochazka, Ivan; Kodet, Jan

    2010-10-01

    We present the experimental results of extremely precise timing in the sense of time-of-arrival measurements in a local time scale. The timing device designed and constructed in our laboratory is based on a new concept using a surface acoustic wave filter as a time interpolator. Construction of the device is briefly described. The experiments described were focused on evaluating the timing precision and stability. Low-jitter test pulses with a repetition frequency of 763 Hz were generated synchronously to the local time base and their times of arrival were measured. The resulting precision of a single measurement was typically 900 fs RMS, and a timing stability TDEV of 4 fs was achieved for time intervals in the range from 300 s to 2 h. To our knowledge this is the best value reported to date for the stability of a timing device. The experimental results are discussed and possible improvements are proposed.

  16. Short time scale laws in self-potentialsignals from two different seismically active Mediterranean areas(the Southern Apennine chainand Crete Island

    Directory of Open Access Journals (Sweden)

    M. Macchiato

    2001-06-01

    Full Text Available Self-potential time series are investigated to characterise self-potential time scales. The data analysed were recorded in stations located in two active seismic areas of the Mediterranean region, the Southern Apennine chain (Giuliano and Crete Island (Heraklion, where in past and recent years many destructive seismic events have taken place. The seismological and geological settings, combined with a low level of cultural noise, allow us to consider these areas ideal outdoor laboratories to study the time dynamics of geophysical parameters of electrical nature. At the same time, the different seismological features of such areas make an inter-comparison between the geoelectrical variability observed at the two sites interesting. Fractal analysis tools, able to detect scale laws and quantify persistence features, are used to better understand the background variability properties of the self-potential signals. As results from our analysis, antipersistence seems to be a ubiquitous feature on short time scales (minutes regardless of environmental conditions. On such scales, the accumulation of random fluctuations is not particularly efficient and significant variations mostly occur as sudden jumps.

  17. Comparison of Sugammadex and Neostigmine in Short Term Surgery

    Directory of Open Access Journals (Sweden)

    Fatih Koc

    2014-03-01

    Full Text Available Aim: This study compared the efficacy and cost effectivines of sugammadex and neostigmine for reversal of neuromuscular blockade induced by rocuronium for short term elective surgery. Material and Method: After written informed consent, 33 patients aged 18%u201365, ASA I-III, who were undergoing short term surgery (

  18. Validity and Responsiveness of the Short Version of the Western Ontario Rotator Cuff Index (Short-WORC) in Patients With Rotator Cuff Repair.

    Science.gov (United States)

    Dewan, Neha; MacDermid, Joy C; MacIntyre, Norma

    2018-05-01

    Study Design Clinical measurement. Background Recently, the Western Ontario Rotator Cuff Index (WORC) was shortened, but few studies have reported its measurement properties. Objective To compare the validity and responsiveness of the short version of the Western Ontario Rotator Cuff Index (Short-WORC) and the WORC (disease-specific measures) with those of the Shoulder Pain and Disability Index (SPADI) and the simple shoulder test (SST) (joint-specific measures); the Disabilities of the Arm, Shoulder and Hand (DASH) (a region-specific measure); and the Medical Outcomes Study 12-Item Short-Form Health Survey version 2 (SF-12v2) (a general health status measure) in patients undergoing rotator cuff repair (RCR). Methods A cohort of patients (n = 223) completed the WORC, SPADI, SST, DASH, and SF-12v2 preoperatively and at 3 and 6 months after RCR. Short-WORC scores were extracted from the WORC questionnaire. The construct validity (Pearson correlations) and internal responsiveness (effect size [ES], standardized response mean [SRM], relative efficiency [RE]) of the Short-WORC were calculated. Results The Short-WORC was strongly correlated with the WORC (r = 0.89-0.96) and moderately to strongly correlated with non-disease-specific measures at preoperative and postoperative assessments (r = 0.51-0.92). The Short-WORC and WORC were equally responsive (RE Short-WORC/WORC = 1) at 0 to 6 months and highly responsive overall at 0 to 3 months (ES Short-WORC , 0.72; ES WORC , 0.92; SRM Short-WORC , 0.75; SRM WORC , 0.81) and 0 to 6 months (ES Short-WORC , 1.05; ES WORC , 1.12; SRM Short-WORC , 0.89; SRM WORC , 0.89). The responsiveness of the comparator measures (SPADI, SST, DASH, SF-12v2) was poor to moderate at 0 to 3 months (ES, 0.07-0.55; SRM, 0.09-0.49) and 0 to 6 months (ES, 0.05-0.78; SRM, 0.07-0.78). Conclusion The Short-WORC and WORC have similar responsiveness in patients undergoing RCR, and are more responsive than non-disease-specific measures. Future studies

  19. Randomized Vehicle-Controlled Study of Short Drug Incubation Aminolevulinic Acid Photodynamic Therapy for Actinic Keratoses of the Face or Scalp.

    Science.gov (United States)

    Pariser, David M; Houlihan, Anna; Ferdon, Mary Beth; Berg, James E

    2016-03-01

    Aminolevulinic acid photodynamic therapy (ALA-PDT) can be effective and well tolerated when applied over a broad area and for short drug incubation times. To evaluate the effect of short-incubation time and application method on the safety and efficacy of ALA-PDT versus vehicle (VEH-PDT) in the treatment of actinic keratoses (AKs) of the face or scalp. Aminolevulinic acid or VEH was applied to face or scalp as a broad area application for 1, 2, or 3 hours or as a spot application for 2 hours before blue light activation. An identical treatment was repeated at Week 8 if any AK lesions remained. Median AK clearance rate for ALA-treated subjects ranged from 68% to 79% at Week 12, compared with 7% of the VEH-treated group (p 47) at Week 12, compared with 2% (1/46) of the VEH-treated group (p = .0041). The safety profile seen in this study is consistent with previously reported side effects of the therapy. Short-incubation ALA-PDT was found to be superior to VEH-PDT for AK lesion clearance. A second treatment improves efficacy.

  20. Fully-automated identification of fish species based on otolith contour: using short-time Fourier transform and discriminant analysis (STFT-DA).

    Science.gov (United States)

    Salimi, Nima; Loh, Kar Hoe; Kaur Dhillon, Sarinder; Chong, Ving Ching

    2016-01-01

    Background. Fish species may be identified based on their unique otolith shape or contour. Several pattern recognition methods have been proposed to classify fish species through morphological features of the otolith contours. However, there has been no fully-automated species identification model with the accuracy higher than 80%. The purpose of the current study is to develop a fully-automated model, based on the otolith contours, to identify the fish species with the high classification accuracy. Methods. Images of the right sagittal otoliths of 14 fish species from three families namely Sciaenidae, Ariidae, and Engraulidae were used to develop the proposed identification model. Short-time Fourier transform (STFT) was used, for the first time in the area of otolith shape analysis, to extract important features of the otolith contours. Discriminant Analysis (DA), as a classification technique, was used to train and test the model based on the extracted features. Results. Performance of the model was demonstrated using species from three families separately, as well as all species combined. Overall classification accuracy of the model was greater than 90% for all cases. In addition, effects of STFT variables on the performance of the identification model were explored in this study. Conclusions. Short-time Fourier transform could determine important features of the otolith outlines. The fully-automated model proposed in this study (STFT-DA) could predict species of an unknown specimen with acceptable identification accuracy. The model codes can be accessed at http://mybiodiversityontologies.um.edu.my/Otolith/ and https://peerj.com/preprints/1517/. The current model has flexibility to be used for more species and families in future studies.

  1. Comparing Part-time Employment in Germany, Sweden, Ireland and the Netherland

    DEFF Research Database (Denmark)

    Bekker, Sonja; Hipp, Lena; Leschke, Janine

    2017-01-01

    In the current discussions on combining work and family, the idea of shorter working hours is becoming ever more popular. However, much of the research on part-time employment has looked at women and mothers in particular. Much less is known about part-time work among men or fathers. Therefore......, this paper aims to establish the differences and similarities between men and women and particularly between mothers and fathers in their choices to work parttime, taking into account different household contexts and welfare state institutions. By analysing part-time work in Germany, Sweden, Ireland...... and the Netherlands in 2014 using individual level data from the European Labour Force Survey, we show that for men a lower earning capacity compared to their partner or family responsibilities do not seem to lead to higher part-time shares. This is the opposite of what we find for women. According to our analysis...

  2. TIME ZONE DIFFERENCE, COMPARATIVE ADVANTAGE AND TRADE: A REVIEW OF LITERATURE

    Directory of Open Access Journals (Sweden)

    Alaka Shree Prasad

    2017-09-01

    Full Text Available With the growing development in communication technology and increased fragmentation of production process, services that were once considered non-tradable can now be traded across different nations. In this respect, trading countries located in different time zones of the world with non-overlapping working hours are able to develop a comparative advantage together for the supply of these services. Disintegrating the production of a service across different time zones can allow the production to be completed efficiently and make the product available in the market meeting consumer demand in a timely fashion. In this paper, we have reviewed some of important research that has been conducted in the area of time zone differences and trade. This type of trade further affects the factor market and production patterns of the involved countries and has also been significant for their growth and welfare.

  3. Short-Term Solar Forecasting Performance of Popular Machine Learning Algorithms: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Florita, Anthony R [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Elgindy, Tarek [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hodge, Brian S [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Dobbs, Alex [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-10-03

    A framework for assessing the performance of short-term solar forecasting is presented in conjunction with a range of numerical results using global horizontal irradiation (GHI) from the open-source Surface Radiation Budget (SURFRAD) data network. A suite of popular machine learning algorithms is compared according to a set of statistically distinct metrics and benchmarked against the persistence-of-cloudiness forecast and a cloud motion forecast. Results show significant improvement compared to the benchmarks with trade-offs among the machine learning algorithms depending on the desired error metric. Training inputs include time series observations of GHI for a history of years, historical weather and atmospheric measurements, and corresponding date and time stamps such that training sensitivities might be inferred. Prediction outputs are GHI forecasts for 1, 2, 3, and 4 hours ahead of the issue time, and they are made for every month of the year for 7 locations. Photovoltaic power and energy outputs can then be made using the solar forecasts to better understand power system impacts.

  4. Short-term stress enhances cellular immunity and increases early resistance to squamous cell carcinoma.

    Science.gov (United States)

    Dhabhar, Firdaus S; Saul, Alison N; Daugherty, Christine; Holmes, Tyson H; Bouley, Donna M; Oberyszyn, Tatiana M

    2010-01-01

    In contrast to chronic/long-term stress that suppresses/dysregulates immune function, an acute/short-term fight-or-flight stress response experienced during immune activation can enhance innate and adaptive immunity. Moderate ultraviolet-B (UV) exposure provides a non-invasive system for studying the naturalistic emergence, progression and regression of squamous cell carcinoma (SCC). Because SCC is an immunoresponsive cancer, we hypothesized that short-term stress experienced before UV exposure would enhance protective immunity and increase resistance to SCC. Control and short-term stress groups were treated identically except that the short-term stress group was restrained (2.5h) before each of nine UV-exposure sessions (minimum erythemal dose, 3-times/week) during weeks 4-6 of the 10-week UV exposure protocol. Tumors were measured weekly, and tissue collected at weeks 7, 20, and 32. Chemokine and cytokine gene expression was quantified by real-time PCR, and CD4+ and CD8+ T cells by flow cytometry and immunohistochemistry. Compared to controls, the short-term stress group showed greater cutaneous T-cell attracting chemokine (CTACK)/CCL27, RANTES, IL-12, and IFN-gamma gene expression at weeks 7, 20, and 32, higher skin infiltrating T cell numbers (weeks 7 and 20), lower tumor incidence (weeks 11-20) and fewer tumors (weeks 11-26). These results suggest that activation of short-term stress physiology increased chemokine expression and T cell trafficking and/or function during/following UV exposure, and enhanced Type 1 cytokine-driven cell-mediated immunity that is crucial for resistance to SCC. Therefore, the physiological fight-or-flight stress response and its adjuvant-like immuno-enhancing effects, may provide a novel and important mechanism for enhancing immune system mediated tumor-detection/elimination that merits further investigation.

  5. Analyses of kinetic glass transition in short-range attractive colloids based on time-convolutionless mode-coupling theory.

    Science.gov (United States)

    Narumi, Takayuki; Tokuyama, Michio

    2017-03-01

    For short-range attractive colloids, the phase diagram of the kinetic glass transition is studied by time-convolutionless mode-coupling theory (TMCT). Using numerical calculations, TMCT is shown to recover all the remarkable features predicted by the mode-coupling theory for attractive colloids: the glass-liquid-glass reentrant, the glass-glass transition, and the higher-order singularities. It is also demonstrated through the comparisons with the results of molecular dynamics for the binary attractive colloids that TMCT improves the critical values of the volume fraction. In addition, a schematic model of three control parameters is investigated analytically. It is thus confirmed that TMCT can describe the glass-glass transition and higher-order singularities even in such a schematic model.

  6. Influences of a yoga intervention on the postural skills of the Italian short track speed skating team

    Science.gov (United States)

    Brunelle, Jean-François; Blais-Coutu, Sébastien; Gouadec, Kenan; Bédard, Éric; Fait, Philippe

    2015-01-01

    Introduction In preparation for a short track speed skating season, eight men and seven women were given yoga sessions during an 8-week high volume training cycle. The sessions were planned according to the postural aspects specific to short track speed skating technical requirements. Three specific goals were selected for the intervention: 1) to observe whether the practice of yoga as postural training could improve the efficiency and the athlete’s repertoire along the muscular synergies solicited in the short track speed skating specific technique; 2) to enhance and diversify the motor time-on-task of athletes without changing the prescription of other training stimulus; and 3) to lower the risk of injury during periods with high volumes of training. Methods A total of 36 sessions of yoga were given. Three postural tests were administered before and after the intervention with 14 angles analyzed. Non-parametric Wilcoxon test was used to compare angles’ variations. Results The 36 yoga sessions totalized 986 minutes of motor time-on-task, registering a proportion of 30% of the global motor time-on-task of the training cycle. Improvements were found in eleven of the 14 angles measured when comparing pre- and post-postural tests (P-value from 0.01 to 0.005). During the 8 weeks, excepting traumatic injuries due to short track speed skating accidents, no skaters suffered injuries linked to the high volume of training. Following the intervention, coaches noticed, following their on-ice feedbacks, an adjustment in the efficiency of the skating technique, in particular regarding hip dissociation. Conclusion These results suggest that yoga could be inserted into out-of-season training cycles, even in a high volume training cycle. Planned with the decision training tools, it allows athletes to diversify their motor time-on-task by integrating a new functional range of generic movements with the solicitation of neuromuscular synergies related to the specificity of their

  7. Evaluation of short repetition time, partial flip angle, gradient recalled echo pulse sequences in cervical spine imaging

    International Nuclear Information System (INIS)

    Enzmann, D.; Rubin, J.B.

    1987-01-01

    A short repetition time (TR), partial flip angle, gradient recalled echo pulse sequence (GRASS) was prospectively studied to optimize it for the diagnosis of cervical disk and cord disease in 98 patients. Changes in signal-to-noise ratio (SNR) and contrast were measured as the following parameters were varied: flip angle (3 0 to 18 0 ), TR (22-60 msec), and echo time (TE) (12.5-25 msec). Flip angle was the single most important parameter. For disk disease, cerebrospinal fluid (CSF) SNR peaked at an 8 0 flip angle in the axial view but at a 4 0 flip angle in the sagittal view. In the sagittal view, disk-CSF contrast decreased progressively from a flip angle of 3 0 , while in the axial view it peaked at 10 0 . For cord lesions the findings were similar except that lesion-cord contrast could be increased by lengthening both TR and TE. No one combination of parameters proved greatly superior for either disk disease or cord disease. The selection of parameters required balancing of several factors that often had opposing effects

  8. Nucleoside uptake in macrophages from various murine strains: a short-time and a two-step stimulation model

    International Nuclear Information System (INIS)

    Busolo, F.; Conventi, L.; Grigolon, M.; Palu, G.

    1991-01-01

    Kinetics of [3H]-uridine uptake by murine peritoneal macrophages (pM phi) is early altered after exposure to a variety of stimuli. Alterations caused by Candida albicans, lipopolysaccharide (LPS) and recombinant interferon-gamma (rIFN-gamma) were similar in SAVO, C57BL/6, C3H/HeN and C3H/HeJ mice, and were not correlated with an activation process as shown by the amount of tumor necrosis factor-alpha (TNF-alpha) being released. Short-time exposure to all stimuli resulted in an increased nucleoside uptake by SAVO pM phi, suggesting that the tumoricidal function of this cell either depends from the type of stimulus or the time when the specific interaction with the cell receptor is taking place. Experiments with priming and triggering signals confirmed the above findings, indicating that the increase or the decrease of nucleoside uptake into the cell depends essentially on the chemical nature of the priming stimulus. The triggering stimulus, on the other hand, is only able to amplify the primary response

  9. Short-term effects of playing computer games on attention.

    Science.gov (United States)

    Tahiroglu, Aysegul Yolga; Celik, Gonca Gul; Avci, Ayse; Seydaoglu, Gulsah; Uzel, Mehtap; Altunbas, Handan

    2010-05-01

    The main aim of the present study is to investigate the short-term cognitive effects of computer games in children with different psychiatric disorders and normal controls. One hundred one children are recruited for the study (aged between 9 and 12 years). All participants played a motor-racing game on the computer for 1 hour. The TBAG form of the Stroop task was administered to all participants twice, before playing and immediately after playing the game. Participants with improved posttest scores, compared to their pretest scores, used the computer on average 0.67 +/- 1.1 hr/day, while the average administered was measured at 1.6 +/- 1.4 hr/day and 1.3 +/- 0.9 hr/day computer use for participants with worse or unaltered scores, respectively. According to the regression model, male gender, younger ages, duration of daily computer use, and ADHD inattention type were found to be independent risk factors for worsened posttest scores. Time spent playing computer games can exert a short-term effect on attention as measured by the Stroop test.

  10. Remote sensing analysis of vegetation recovery following short-interval fires in Southern California shrublands.

    Science.gov (United States)

    Meng, Ran; Dennison, Philip E; D'Antonio, Carla M; Moritz, Max A

    2014-01-01

    Increased fire frequency has been shown to promote alien plant invasions in the western United States, resulting in persistent vegetation type change. Short interval fires are widely considered to be detrimental to reestablishment of shrub species in southern California chaparral, facilitating the invasion of exotic annuals and producing "type conversion". However, supporting evidence for type conversion has largely been at local, site scales and over short post-fire time scales. Type conversion has not been shown to be persistent or widespread in chaparral, and past range improvement studies present evidence that chaparral type conversion may be difficult and a relatively rare phenomenon across the landscape. With the aid of remote sensing data covering coastal southern California and a historical wildfire dataset, the effects of short interval fires (<8 years) on chaparral recovery were evaluated by comparing areas that burned twice to adjacent areas burned only once. Twelve pairs of once- and twice-burned areas were compared using normalized burn ratio (NBR) distributions. Correlations between measures of recovery and explanatory factors (fire history, climate and elevation) were analyzed by linear regression. Reduced vegetation cover was found in some lower elevation areas that were burned twice in short interval fires, where non-sprouting species are more common. However, extensive type conversion of chaparral to grassland was not evident in this study. Most variables, with the exception of elevation, were moderately or poorly correlated with differences in vegetation recovery.

  11. Global Erratum for Kepler Q0-Q17 and K2 C0-C5 Short Cadence Data

    Science.gov (United States)

    Caldwell, Douglas; Van Cleve, Jeffrey E.

    2016-01-01

    An accounting error has scrambled much of the short-cadence collateral smear data used to correct for the effects of Keplers shutterless readout. This error has been present since launch and affects approximately half of all short-cadence targets observed by Kepler and K2 to date. The resulting calibration errors are present in both the short-cadence target pixel files and the short-cadence light curves for Kepler Data Releases 1-24 and K2 Data Releases 1-7. This error does not affect long-cadence data. Since it will take some time to correct this error and reprocess all Kepler and K2 data, a list of affected targets is provided. Even though the affected targets are readily identified, the science impact for any particular target may be difficult to assess. Since the smear signal is often small compared to the target signal, the effect is negligible for many targets. However, the smear signal is scene-dependent, so time varying signals can be introduced into any target by the other stars falling on the same CCD column. Some tips on how to assess the severity of the calibration error are provided in this document.

  12. Prospective testing of Coulomb short-term earthquake forecasts

    Science.gov (United States)

    Jackson, D. D.; Kagan, Y. Y.; Schorlemmer, D.; Zechar, J. D.; Wang, Q.; Wong, K.

    2009-12-01

    Earthquake induced Coulomb stresses, whether static or dynamic, suddenly change the probability of future earthquakes. Models to estimate stress and the resulting seismicity changes could help to illuminate earthquake physics and guide appropriate precautionary response. But do these models have improved forecasting power compared to empirical statistical models? The best answer lies in prospective testing in which a fully specified model, with no subsequent parameter adjustments, is evaluated against future earthquakes. The Center of Study of Earthquake Predictability (CSEP) facilitates such prospective testing of earthquake forecasts, including several short term forecasts. Formulating Coulomb stress models for formal testing involves several practical problems, mostly shared with other short-term models. First, earthquake probabilities must be calculated after each “perpetrator” earthquake but before the triggered earthquakes, or “victims”. The time interval between a perpetrator and its victims may be very short, as characterized by the Omori law for aftershocks. CSEP evaluates short term models daily, and allows daily updates of the models. However, lots can happen in a day. An alternative is to test and update models on the occurrence of each earthquake over a certain magnitude. To make such updates rapidly enough and to qualify as prospective, earthquake focal mechanisms, slip distributions, stress patterns, and earthquake probabilities would have to be made by computer without human intervention. This scheme would be more appropriate for evaluating scientific ideas, but it may be less useful for practical applications than daily updates. Second, triggered earthquakes are imperfectly recorded following larger events because their seismic waves are buried in the coda of the earlier event. To solve this problem, testing methods need to allow for “censoring” of early aftershock data, and a quantitative model for detection threshold as a function of

  13. Assessing multiscale complexity of short heart rate variability series through a model-based linear approach

    Science.gov (United States)

    Porta, Alberto; Bari, Vlasta; Ranuzzi, Giovanni; De Maria, Beatrice; Baselli, Giuseppe

    2017-09-01

    We propose a multiscale complexity (MSC) method assessing irregularity in assigned frequency bands and being appropriate for analyzing the short time series. It is grounded on the identification of the coefficients of an autoregressive model, on the computation of the mean position of the poles generating the components of the power spectral density in an assigned frequency band, and on the assessment of its distance from the unit circle in the complex plane. The MSC method was tested on simulations and applied to the short heart period (HP) variability series recorded during graded head-up tilt in 17 subjects (age from 21 to 54 years, median = 28 years, 7 females) and during paced breathing protocols in 19 subjects (age from 27 to 35 years, median = 31 years, 11 females) to assess the contribution of time scales typical of the cardiac autonomic control, namely in low frequency (LF, from 0.04 to 0.15 Hz) and high frequency (HF, from 0.15 to 0.5 Hz) bands to the complexity of the cardiac regulation. The proposed MSC technique was compared to a traditional model-free multiscale method grounded on information theory, i.e., multiscale entropy (MSE). The approach suggests that the reduction of HP variability complexity observed during graded head-up tilt is due to a regularization of the HP fluctuations in LF band via a possible intervention of sympathetic control and the decrement of HP variability complexity observed during slow breathing is the result of the regularization of the HP variations in both LF and HF bands, thus implying the action of physiological mechanisms working at time scales even different from that of respiration. MSE did not distinguish experimental conditions at time scales larger than 1. Over a short time series MSC allows a more insightful association between cardiac control complexity and physiological mechanisms modulating cardiac rhythm compared to a more traditional tool such as MSE.

  14. Deficits in verbal long-term memory and learning in children with poor phonological short-term memory skills.

    Science.gov (United States)

    Gathercole, Susan E; Briscoe, Josie; Thorn, Annabel; Tiffany, Claire

    2008-03-01

    Possible links between phonological short-term memory and both longer term memory and learning in 8-year-old children were investigated in this study. Performance on a range of tests of long-term memory and learning was compared for a group of 16 children with poor phonological short-term memory skills and a comparison group of children of the same age with matched nonverbal reasoning abilities but memory scores in the average range. The low-phonological-memory group were impaired on longer term memory and learning tasks that taxed memory for arbitrary verbal material such as names and nonwords. However, the two groups performed at comparable levels on tasks requiring the retention of visuo-spatial information and of meaningful material and at carrying out prospective memory tasks in which the children were asked to carry out actions at a future point in time. The results are consistent with the view that poor short-term memory function impairs the longer-term retention and ease of learning of novel verbal material.

  15. Cost and time models for the evaluation of intermodal chains by using short sea shipping in the North Sea Region: the Rosyth-Zeebrugge route

    DEFF Research Database (Denmark)

    Lopez, Alba Martínez; Kronbak, Jacob; Jiang, Liping

    2015-01-01

    This paper is framed in the context of the EU Interreg IVB North Sea Region project Food Port. In line with this project, this paper aims to define mathematically cost and time models able to provide realistic information about the performances of road haulage and of intermodal chains using short...

  16. R package imputeTestbench to compare imputations methods for univariate time series

    OpenAIRE

    Bokde, Neeraj; Kulat, Kishore; Beck, Marcus W; Asencio-Cortés, Gualberto

    2016-01-01

    This paper describes the R package imputeTestbench that provides a testbench for comparing imputation methods for missing data in univariate time series. The imputeTestbench package can be used to simulate the amount and type of missing data in a complete dataset and compare filled data using different imputation methods. The user has the option to simulate missing data by removing observations completely at random or in blocks of different sizes. Several default imputation methods are includ...

  17. Insomnia with objective short sleep duration is associated with longer duration of insomnia in the Freiburg Insomnia Cohort compared to insomnia with normal sleep duration, but not with hypertension.

    Science.gov (United States)

    Johann, Anna F; Hertenstein, Elisabeth; Kyle, Simon D; Baglioni, Chiara; Feige, Bernd; Nissen, Christoph; McGinness, Alastair J; Riemann, Dieter; Spiegelhalder, Kai

    2017-01-01

    To replicate the association between insomnia with objective short sleep duration and hypertension, type 2 diabetes and duration of insomnia. Retrospective case-control study. Department of Psychiatry and Psychotherapy, Medical Center-University of Freiburg. 328 patients with primary insomnia classified according to DSM-IV criteria (125 males, 203 females, 44.3 ± 12.2 years). N/A. All participants were investigated using polysomnography, blood pressure measurements, and fasting routine laboratory. Insomnia patients with short sleep duration (insomnia compared to those with normal sleep duration (≥ 6 hours) in the first night of laboratory sleep. Insomnia patients who were categorised as short sleepers in either night were not more likely to suffer from hypertension (systolic blood pressure of ≥ 140 mm Hg, diastolic blood pressure of ≥ 90 mm Hg, or a previously established diagnosis). Data analysis showed that insomnia patients with objective short sleep duration were not more likely to suffer from type 2 diabetes (fasting plasma glucose level of ≥ 126 mg/dl, or a previously established diagnosis). However, the diabetes analysis was only based on a very small number of diabetes cases. As a new finding, insomnia patients who were categorised as short sleepers in either night presented with increases in liver enzyme levels. The finding on insomnia duration supports the concept of two distinct sub-groups of insomnia, namely insomnia with, and without, objectively determined short sleep duration. However, our data challenges previous findings that insomnia patients with short sleep duration are more likely to suffer from hypertension.

  18. Effects of zebra mussels on food webs: Interactions with juvenile bluegill and water residence time

    Science.gov (United States)

    Richardson, W.B.; Bartsch, L.A.

    1997-01-01

    We evaluated how water residence time mediated the impact of zebra mussels Dreissena polymorpha and bluegill sunfish Lepomis macrochirus on experimental food webs established in 1100-1 outdoor mesocosms. Water residence time was manipulated as a surrogate for seston resupply - a critical variable affecting growth and survival of suspension-feeding invertebrates. We used a 2 x 2 x 2 factorial experimental design with eight treatment combinations (3 replicates/treatment) including the presence or absence of Dreissena (2000 per m2), juvenile bluegill (40 per mesocosm), and short (1100 1 per d) or long (220 1 per d) water residence time. Measures of seston concentration (chlorophyll a, turbidity and suspended solids) were greater in the short- compared to long water-residence mesocosms, but intermediate in short water-residence mesocosms containing Dreissena. Abundance of rotifers (Keratella and Polyarthra) was reduced in Dreissena mesocosms and elevated in short residence time mesocosms. Cladocera abundance, in general, was unaffected by the presence of Dreissena; densities were higher in short-residence time mesocosms, and reduced in the presence of Lepomis. The growth of juvenile Lepomis were unaffected by Dreissena because of abundant benthic food. The final total mass of Dreissena was significantly greater in short- than long-residence mesocosms. Impacts of Dreissena on planktonic food webs may not only depend on the density of zebra mussels but also on the residence time of the surrounding water and the resupply of seston. ?? 1997 Kluwer Academic Publishers.

  19. Short linear shadows connecting pulmonary segmental arteries to oblique fissures in volumetric thin-section CT images: comparing CT, micro-CT and histopathology

    International Nuclear Information System (INIS)

    Guan, Chun-Shuang; Ma, Da-Qing; Chen, Jiang-Hong; Chen, Bu-Dong; Cui, Dun; Zhang, Yan-Song; Liu, Wei-Hua

    2016-01-01

    To retrospectively evaluate short linear shadows connecting pulmonary segmental arteries to oblique fissures in thin-section CT images and determine their anatomical basis. CT scanning was performed on 108 patients and 11 lung specimens with no lung diseases around the oblique fissures or hilar. Two radiologists evaluated the imaging. The parameters included length, thickness of short linear shadows, pulmonary segmental artery variations, and traction interlobar fissures, etc. The short linear shadows were not related to sex, age, or smoking history. The lengths of the short linear shadows were generally within 10 mm. The thicknesses of the short linear shadows ranged from 1 to 2 mm. Of the patients, 26.9 % showed pulmonary segmental artery variations; 66.7 % of short linear shadows pulled oblique fissures. In three-dimensional images, the short linear shadows appeared as arc planes, with one side edge connected to the oblique fissure, one side edge connected to a pulmonary segmental artery. On the tissue slices, the short linear shadow exhibited a band structure composed of connective tissues, small blood vessels, and small lymphatic vessels. Short linear shadows are a type of normal intrapulmonary membranes and can maintain the integrity of the oblique fissures and hilar structure. (orig.)

  20. Effects of stress on heart rate complexity--a comparison between short-term and chronic stress.

    Science.gov (United States)

    Schubert, C; Lambertz, M; Nelesen, R A; Bardwell, W; Choi, J-B; Dimsdale, J E

    2009-03-01

    This study examined chronic and short-term stress effects on heart rate variability (HRV), comparing time, frequency and phase domain (complexity) measures in 50 healthy adults. The hassles frequency subscale of the combined hassles and uplifts scale (CHUS) was used to measure chronic stress. Short-term stressor reactivity was assessed with a speech task. HRV measures were determined via surface electrocardiogram (ECG). Because respiration rate decreased during the speech task (pshort-term stress decreased HR D2 (calculated via the pointwise correlation dimension PD2) (pshort-term stress. Partial correlation adjusting for respiration rate showed that HR D2 was associated with chronic stress (r=-.35, p=.019). Differential effects of chronic and short-term stress were observed on several HRV measures. HR D2 decreased under both stress conditions reflecting lowered functionality of the cardiac pacemaker. The results confirm the importance of complexity metrics in modern stress research on HRV.