WorldWideScience

Sample records for short test standards

  1. Thirteen years test experience with short-circuit withstand capability of large power transformers

    NARCIS (Netherlands)

    Smeets, R.P.P.; Paske, te L.H.; Leufkens, P.P.; Fogelberg, T.

    2009-01-01

    The ability to withstand a short circuit is recognised more and more as an essential characteristic of power transformers. IEC and IEEE Standards, as well as other national standards specify short-circuit testing and how to check the withstand capability. Unfortunately, however, there is extensive

  2. Fourteen years of test experience with short-circuit withstand capability of large power transformers

    NARCIS (Netherlands)

    Smeets, R.P.P.; Paske, te L.H.

    2010-01-01

    Experience is reported of short-circuit testing of large power transformers during the past 14 years by KEMA in the Netherlands. In total, 119 transformers > 25 MVA participated in the survey. KEMA shows that at initial access to standard IEC short-circuit tests, 28% failed initially in a wide range

  3. Sixteen years of test experiences with short-circuit withstand capability of large power transformers

    NARCIS (Netherlands)

    Smeets, R.P.P.; Paske, te L.H.

    2012-01-01

    Experience is reported of short-circuit testing of large power transformers during the past 16 years by KEMA in the Netherlands. In total, 174 transformers > 25 MVA participated in the survey. KEMA shows that at initial access to standard IEC short-circuit tests, 24% failed initially in a wide range

  4. Short- circuit tests of circuit breakers

    OpenAIRE

    Chorovský, P.

    2015-01-01

    This paper deals with short-circuit tests of low voltage electrical devices. In the first part of this paper, there are described basic types of short- circuit tests and their principles. Direct and indirect (synthetic) tests with more details are described in the second part. Each test and principles are explained separately. Oscilogram is obtained from short-circuit tests of circuit breakers at laboratory. The aim of this research work is to propose a test circuit for performing indirect test.

  5. The Analysis of the Psychological Tests Using In Educational Institutions According To the Testing Standards

    Directory of Open Access Journals (Sweden)

    Ezgi MOR DİRLİK

    2017-12-01

    Full Text Available The purpose of this research is to analyze four psychological tests which are frequently used in the Guidance and Research Centers and in the guidance services of the schools according to the standards for educational and psychological testing of APA (American Psychological Association and test adaption standards of ITC (International Testing Commission. The tests were determined based on the goal- oriented sample selecting method and were selected from the most frequently used psychological tests in Guidance and Research Centers and school’s guidance centers. These tests are: Scale of Academic Self-Concept (Akademik Benlik Kavramı Ölçeği-ABKÖ, Evaluation of Early Childhood Development Tool (Gazi Erken Çocukluk Gelişimi Değerlendirme Aracı-GEÇDA, Primary Mental Abilities 7-11 (TKT 7-11, and Wechsler Intelligence Scale for Children Revised Form (WISC-R. In this research, the chapters related to the validity, reliability and test development and revision of “Standards For Educational And Psychological Testing” (APA, 1999 and the adaptation standards developed by ITC were translated into Turkish and a checklist was created by using these documents. The checklist has got two forms as short and long form. The tests were analyzed according to the short form of the checklist by researcher. In order to examine the reliability of these analyses, the analyses were repeated in three weeks’ time. Data of these analyses were exported to the Statistical Package for Social Sciences (SPSS 20.0 and descriptive analysis was perfomed. As a result of this research, the meeting levels of the psychological tests to the test standards in the checklist and the features of the tests which should be improved according to the validity, reliability, test development and revision and test adaptation were determined. In conclusion, the standards analyzed have not been met satisfactorily by ABKÖ and GEÇDA, and according to the analyses of the realibility

  6. Standard Test Method for Determining the Linearity of a Photovoltaic Device Parameter with Respect To a Test Parameter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method determines the degree of linearity of a photovoltaic device parameter with respect to a test parameter, for example, short-circuit current with respect to irradiance. 1.2 The linearity determined by this test method applies only at the time of testing, and implies no past or future performance level. 1.3 This test method applies only to non-concentrator terrestrial photovoltaic devices. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  7. Non-standard patch test

    Directory of Open Access Journals (Sweden)

    Astri Adelia

    2018-06-01

    Full Text Available In managing contact dermatitis, identification of the causative agent is essential to prevent recurrent complaints. Patch test is the gold standard to identify the causative agent. Nowadays, there are many patch test standard materials available in the market, but do not include all the materials that potentially cause contact dermatitis. Patch test using patient’s own products or later we refer to as non-standard materials, is very helpful in identifying the causative agents of contact dermatitis. Guidance is needed in producing non-standard patch test materials in order to avoid test results discrepancy.

  8. Short-term test-retest-reliability of conditioned pain modulation using the cold-heat-pain method in healthy subjects and its correlation to parameters of standardized quantitative sensory testing.

    Science.gov (United States)

    Gehling, Julia; Mainka, Tina; Vollert, Jan; Pogatzki-Zahn, Esther M; Maier, Christoph; Enax-Krumova, Elena K

    2016-08-05

    Conditioned Pain Modulation (CPM) is often used to assess human descending pain inhibition. Nine different studies on the test-retest-reliability of different CPM paradigms have been published, but none of them has investigated the commonly used heat-cold-pain method. The results vary widely and therefore, reliability measures cannot be extrapolated from one CPM paradigm to another. Aim of the present study was to analyse the test-retest-reliability of the common heat-cold-pain method and its correlation to pain thresholds. We tested the short-term test-retest-reliability within 40 ± 19.9 h using a cold-water immersion (10 °C, left hand) as conditioning stimulus (CS) and heat pain (43-49 °C, pain intensity 60 ± 5 on the 101-point numeric rating scale, right forearm) as test stimulus (TS) in 25 healthy right-handed subjects (12females, 31.6 ± 14.1 years). The TS was applied 30s before (TSbefore), during (TSduring) and after (TSafter) the 60s CS. The difference between the pain ratings for TSbefore and TSduring represents the early CPM-effect, between TSbefore and TSafter the late CPM-effect. Quantitative sensory testing (QST, DFNS protocol) was performed on both sessions before the CPM assessment. paired t-tests, Intraclass correlation coefficient (ICC), standard error of measurement (SEM), smallest real difference (SRD), Pearson's correlation, Bland-Altman analysis, significance level p Pain ratings during CPM correlated significantly (ICC: 0.411…0.962) between both days, though ratings for TSafter were lower on day 2 (p pain thresholds. The short-term test-retest-reliability of the early CPM-effect using the heat-cold-pain method in healthy subjects achieved satisfying results in terms of the ICC. The SRD of the early CPM effect showed that an individual change of > 20 NRS can be attributed to a real change rather than chance. The late CPM-effect was weaker and not reliable.

  9. The Standard-Model Extension and Gravitational Tests

    Directory of Open Access Journals (Sweden)

    Jay D. Tasson

    2016-10-01

    Full Text Available The Standard-Model Extension (SME provides a comprehensive effective field-theory framework for the study of CPT and Lorentz symmetry. This work reviews the structure and philosophy of the SME and provides some intuitive examples of symmetry violation. The results of recent gravitational tests performed within the SME are summarized including analysis of results from the Laser Interferometer Gravitational-Wave Observatory (LIGO, sensitivities achieved in short-range gravity experiments, constraints from cosmic-ray data, and results achieved by studying planetary ephemerids. Some proposals and ongoing efforts will also be considered including gravimeter tests, tests of the Weak Equivalence Principle, and antimatter experiments. Our review of the above topics is augmented by several original extensions of the relevant work. We present new examples of symmetry violation in the SME and use the cosmic-ray analysis to place first-ever constraints on 81 additional operators.

  10. A comparison of computerized adaptive testing and fixed-length short forms for the Prosthetic Limb Users Survey of Mobility (PLUS-MTM).

    Science.gov (United States)

    Amtmann, Dagmar; Bamer, Alyssa M; Kim, Jiseon; Bocell, Fraser; Chung, Hyewon; Park, Ryoungsun; Salem, Rana; Hafner, Brian J

    2017-09-01

    New health status instruments can be administered by computerized adaptive test or short forms. The Prosthetic Limb Users Survey of Mobility (PLUS-M TM ) is a self-report measure of mobility for prosthesis users with lower limb loss. This study used the PLUS-M to examine advantages and disadvantages of computerized adaptive test and short forms. To compare scores obtained from computerized adaptive test to scores obtained from fixed-length short forms (7-item and 12-item) in order to provide guidance to researchers and clinicians on how to select the best form of administration for different uses. Cross-sectional, observational study. Individuals with lower limb loss completed the PLUS-M by computerized adaptive test and short forms. Administration time, correlations between the scores, and standard errors were compared. Scores and standard errors from the computerized adaptive test, 7-item short form, and 12-item short form were highly correlated and all forms of administration were efficient. Computerized adaptive test required less time to administer than either paper or electronic short forms; however, time savings were minimal compared to the 7-item short form. Results indicate that the PLUS-M computerized adaptive test is most efficient, and differences in scores between administration methods are minimal. The main advantage of the computerized adaptive test was more reliable scores at higher levels of mobility compared to short forms. Clinical relevance Health-related item banks, like the Prosthetic Limb Users Survey of Mobility (PLUS-M TM ), can be administered by computerized adaptive testing (CAT) or as fixed-length short forms (SFs). Results of this study will help clinicians and researchers decide whether they should invest in a CAT administration system or whether SFs are more appropriate.

  11. Composite Reliability and Standard Errors of Measurement for a Seven-Subtest Short Form of the Wechsler Adult Intelligence Scale-Revised.

    Science.gov (United States)

    Schretlen, David; And Others

    1994-01-01

    Composite reliability and standard errors of measurement were computed for prorated Verbal, Performance, and Full-Scale intelligence quotient (IQ) scores from a seven-subtest short form of the Wechsler Adult Intelligence Scale-Revised. Results with 1,880 adults (standardization sample) indicate that this form is as reliable as the complete test.…

  12. Standard-Model Tests with Superallowed β-Decay: An Important Application of Very Precise Mass Measurements

    International Nuclear Information System (INIS)

    Hardy, J. C.; Towner, I. S.

    2001-01-01

    Superallowed β-decay provides a sensitive means for probing the limitations of the Electroweak Standard Model. To date, the strengths (ft-values) of superallowed 0 +→ 0 + β-decay transitions have been determined with high precision from nine different short-lived nuclei, ranging from 10 C to 54 Co. Each result leads to an independent measure for the vector coupling constant G V and collectively the nine values can be used to test the conservation of the weak vector current (CVC). Within current uncertainties, the results support CVC to better than a few parts in 10,000 - a clear success for the Standard Model! However, when the average value of G V , as determined in this way, is combined with data from decays of the muon and kaon to test another prediction of the Standard Model, the result is much more provocative. A test of the unitarity of the Cabibbo-Kobayashi-Maskawa matrix fails by more than two standard deviations. This result can be made more definitive by experiments that require extremely precise mass measurements, in some cases on very short-lived (≤100 ms) nuclei. This talk presents the current status and future prospects for these Standard-Model tests, emphasizing the role of precise mass, or mass-difference measurements. There remains a real challenge to mass-measurement technique with the opportunity for significant new results

  13. Standard Javanese Causatives in online editorials and short stories

    Directory of Open Access Journals (Sweden)

    Noor Malihah

    2014-06-01

    Full Text Available This paper explores the distinctive features of the standard Javanese causatives in on-line editorials and short stories. This research is based on written corpus. This written corpus was compiled from articles published in an online newspaper Solo Pos. To analyze the corpus, I have developed a system of manual annotation to identify the features of verb transitivity, the animacy and humanness of the verb, the presence of active, passive and ergative-like clauses and the number of other grammatical and semantic features using a system of tags. Using this annotation, I analyze the data based on dua anlaysis: genre analysis, functional analysis using a quantitative method. The findings show that genre influences the selection of causative types (markers. Also, there exists gawe used as a verb of causation in both editorials and short stories which contradicts to the canonical rule of the Javanese active verb and Malihah’s (2014 findings. The finding also shows that the standard Javanese causative in online editorials and short stories occurs with intransitive verbs. The last finding is that active clause is the relative prominent type of clause which occurs in all marker. In conclusion, the above findings have made contributions to knowledge to Javanese grammar.

  14. Standard Test Method for Measuring Optical Angular Deviation of Transparent Parts

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1996-01-01

    1.1 This test method covers measuring the angular deviation of a light ray imposed by transparent parts such as aircraft windscreens and canopies. The results are uncontaminated by the effects of lateral displacement, and the procedure may be performed in a relatively short optical path length. This is not intended as a referee standard. It is one convenient method for measuring angular deviations through transparent windows. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  15. Comparing Short Dental Implants to Standard Dental Implants: Protocol for a Systematic Review.

    Science.gov (United States)

    Rokn, Amir Reza; Keshtkar, Abbasali; Monzavi, Abbas; Hashemi, Kazem; Bitaraf, Tahereh

    2018-01-18

    Short dental implants have been proposed as a simpler, cheaper, and faster alternative for the rehabilitation of atrophic edentulous areas to avoid the disadvantages of surgical techniques for increasing bone volume. This review will compare short implants (4 to 8 mm) to standard implants (larger than 8 mm) in edentulous jaws, evaluating on the basis of marginal bone loss (MBL), survival rate, complications, and prosthesis failure. We will electronically search for randomized controlled trials comparing short dental implants to standard dental implants in the following databases: PubMed, Web of Science, EMBASE, Scopus, the Cochrane Central Register of Controlled Trials, and ClinicalTrials.gov with English language restrictions. We will manually search the reference lists of relevant reviews and the included articles in this review. The following journals will also be searched: European Journal of Oral Implantology, Clinical Oral Implants Research, and Clinical Implant Dentistry and Related Research. Two reviewers will independently perform the study selection, data extraction and quality assessment (using the Cochrane Collaboration tool) of included studies. All meta-analysis procedures including appropriate effect size combination, sub-group analysis, meta-regression, assessing publication or reporting bias will be performed using Stata (Statacorp, TEXAS) version 12.1. Short implant effectiveness will be assessed using the mean difference of MBL in terms of weighted mean difference (WMD) and standardized mean difference (SMD) using Cohen's method. The combined effect size measures in addition to the related 95% confidence intervals will be estimated by a fixed effect model. The heterogeneity of the related effect size will be assessed using a Q Cochrane test and I2 measure. The MBL will be presented by a standardized mean difference with a 95% confidence interval. The survival rate of implants, prostheses failures, and complications will be reported using a risk

  16. Quality of Standard Reference Materials for Short Time Activation Analysis

    International Nuclear Information System (INIS)

    Ismail, S.S.; Oberleitner, W.

    2003-01-01

    Some environmental reference materials (CFA-1633 b, IAEA-SL-1, SARM-1,BCR-176, Coal-1635, IAEA-SL-3, BCR-146, and SRAM-5) were analysed by short-time activation analysis. The results show that these materials can be classified in three groups, according to their activities after irradiation. The obtained results were compared in order to create a quality index for determination of short-lived nuclides at high count rates. It was found that Cfta is not a suitable standard for determining very short-lived nuclides (half-lives<1 min) because the activity it produces is 15-fold higher than that SL-3. Biological reference materials, such as SRM-1571, SRM-1573, SRM-1575, SRM-1577, IAEA-392, and IAEA-393, were also investigated by a higher counting efficiency system. The quality of this system and its well-type detector for investigating short-lived nuclides was discussed

  17. Idiopathic short stature

    Directory of Open Access Journals (Sweden)

    Vlaški Jovan

    2013-01-01

    Full Text Available Growth is a complex process and the basic characteristic of child- hood growth monitoring provides insight into the physiological and pathological events in the body. Statistically, the short stature means departure from the values of height for age and sex (in a particular environment, which is below -2 standard deviation score, or less than -2 standard deviation, i.e. below the third percentile. Advances in molecular genetics have contributed to the improvement of diagnostics in endocrinology. Analysis of patients’ genotypes should not be performed before taking a classical history, detailed clinical examination and appropriate tests. In patients with idiopathic short stature specific causes are excluded, such as growth hormone deficiency, Turner syndrome, short stature due to low birth weight, intrauterine growth retardation, small for gestational age, dysmorphology syndromes and chronic childhood diseases. The exclusion of abovementioned conditions leaves a large number of children with short stature whose etiology includes patients with genetic short stature or familial short stature and those who are low in relation to genetic potential, and who could also have some unrecognized endocrine defect. Idiopathic short stature represents a short stature of unknown cause of heterogeneous etiology, and is characterized by a normal response of growth hormone during stimulation tests (>10 ng/ml or 20 mJ/l, without other disorders, of normal body mass and length at birth. In idiopathic short stature standard deviation score rates <-2.25 (-2 to -3 or <1.2 percentile. These are also criteria for the initiation of growth hormone therapy. In children with short stature there is also the presence of psychological and social suffering. Goals of treatment with growth hormone involve achieving normal height and normal growth rate during childhood.

  18. Historical Evolution of NASA Standard Materials Testing with Hypergolic Propellants and Ammonia (NASA Standard 6001 Test 15)

    Science.gov (United States)

    Greene, Benjamin; McClure, Mark B.

    2012-01-01

    The NASA Johnson Space Center White Sands Test Facility (WSTF) has performed testing of hazardous and reactive aerospace fluids, including hypergolic propellants, with materials since the 1960s with the Apollo program. Amongst other test activities, Test 15 is a NASA standard test for evaluating the reactivity of materials with selected aerospace fluids, in particular hydrazine, monomethylhydrazine, uns-dimethylhydrazine, Aerozine 50, dinitrogen tetroxide oxidizers, and ammonia. This manuscript provides an overview of the history of Test 15 over a timeline ranging from prior to its development and first implementation as a NASA standard test in 1974 to its current refinement. Precursor documents to NASA standard tests, as they are currently known, are reviewed. A related supplementary test, international standardization, and enhancements to Test 15 are also discussed. Because WSTF was instrumental in the development and implementation of Test 15, WSTF experience and practices are referred to in this manuscript.

  19. Standard Test Method for Sandwich Corrosion Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method defines the procedure for evaluating the corrosivity of aircraft maintenance chemicals, when present between faying surfaces (sandwich) of aluminum alloys commonly used for aircraft structures. This test method is intended to be used in the qualification and approval of compounds employed in aircraft maintenance operations. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements appear in Section 9.

  20. Concurrent Validity and Feasibility of Short Tests Currently Used to Measure Early Childhood Development in Large Scale Studies.

    Directory of Open Access Journals (Sweden)

    Marta Rubio-Codina

    Full Text Available In low- and middle-income countries (LIMCs, measuring early childhood development (ECD with standard tests in large scale surveys and evaluations of interventions is difficult and expensive. Multi-dimensional screeners and single-domain tests ('short tests' are frequently used as alternatives. However, their validity in these circumstances is unknown. We examined the feasibility, reliability, and concurrent validity of three multi-dimensional screeners (Ages and Stages Questionnaires (ASQ-3, Denver Developmental Screening Test (Denver-II, Battelle Developmental Inventory screener (BDI-2 and two single-domain tests (MacArthur-Bates Short-Forms (SFI and SFII, WHO Motor Milestones (WHO-Motor in 1,311 children 6-42 months in Bogota, Colombia. The scores were compared with those on the Bayley Scales of Infant and Toddler Development (Bayley-III, taken as the 'gold standard'. The Bayley-III was given at a center by psychologists; whereas the short tests were administered in the home by interviewers, as in a survey setting. Findings indicated good internal validity of all short tests except the ASQ-3. The BDI-2 took long to administer and was expensive, while the single-domain tests were quickest and cheapest and the Denver-II and ASQ-3 were intermediate. Concurrent validity of the multi-dimensional tests' cognitive, language, and fine motor scales with the corresponding Bayley-III scale was low below 19 months. However, it increased with age, becoming moderate-to-high over 30 months. In contrast, gross motor scales' concurrence was high under 19 months and then decreased. Of the single-domain tests, the WHO-Motor had high validity with gross motor under 16 months, and the SFI and SFII expressive scales showed moderate correlations with language under 30 months. Overall, the Denver-II was the most feasible and valid multi-dimensional test and the ASQ-3 performed poorly under 31 months. By domain, gross motor development had the highest concurrence

  1. Remembering over the short-term: the case against the standard model.

    Science.gov (United States)

    Nairne, James S

    2002-01-01

    Psychologists often assume that short-term storage is synonymous with activation, a mnemonic property that keeps information in an immediately accessible form. Permanent knowledge is activated, as a result of on-line cognitive processing, and an activity trace is established "in" short-term (or working) memory. Activation is assumed to decay spontaneously with the passage of time, so a refreshing process-rehearsal-is needed to maintain availability. Most of the phenomena of immediate retention, such as capacity limitations and word length effects, are assumed to arise from trade-offs between rehearsal and decay. This "standard model" of how we remember over the short-term still enjoys considerable popularity, although recent research questions most of its main assumptions. In this chapter I review the recent research and identify the empirical and conceptual problems that plague traditional conceptions of short-term memory. Increasingly, researchers are recognizing that short-term retention is cue driven, much like long-term memory, and that neither rehearsal nor decay is likely to explain the particulars of short-term forgetting.

  2. Testing for Short Memory in a VARMA Process

    OpenAIRE

    Oke, Timothy; Öller, Lars-Erik

    1997-01-01

    We generalize the short term memory test of an ARMA model, presented in Öller (1985), to the multivariate VARMA cases. In a study on Swedish exports and OECD demand we demonstrate how the multivariate setting extends the short memory.

  3. Electrical short circuit and current overload tests on aircraft wiring

    Science.gov (United States)

    Cahill, Patricia

    1995-01-01

    The findings of electrical short circuit and current overload tests performed on commercial aircraft wiring are presented. A series of bench-scale tests were conducted to evaluate circuit breaker response to overcurrent and to determine if the wire showed any visible signs of thermal degradation due to overcurrent. Three types of wire used in commercial aircraft were evaluated: MIL-W-22759/34 (150 C rated), MIL-W-81381/12 (200 C rated), and BMS 1360 (260 C rated). A second series of tests evaluated circuit breaker response to short circuits and ticking faults. These tests were also meant to determine if the three test wires behaved differently under these conditions and if a short circuit or ticking fault could start a fire. It is concluded that circuit breakers provided reliable overcurrent protection. Circuit breakers may not protect wire from ticking faults but can protect wire from direct shorts. These tests indicated that the appearance of a wire subjected to a current that totally degrades the insulation looks identical to a wire subjected to a fire; however the 'fire exposed' conductor was more brittle than the conductor degraded by overcurrent. Preliminary testing indicates that direct short circuits are not likely to start a fire. Preliminary testing indicated that direct short circuits do not erode insulation and conductor to the extent that ticking faults did. Circuit breakers may not safeguard against the ignition of flammable materials by ticking faults. The flammability of materials near ticking faults is far more important than the rating of the wire insulation material.

  4. Testing the Standard Model

    CERN Document Server

    Riles, K

    1998-01-01

    The Large Electron Project (LEP) accelerator near Geneva, more than any other instrument, has rigorously tested the predictions of the Standard Model of elementary particles. LEP measurements have probed the theory from many different directions and, so far, the Standard Model has prevailed. The rigour of these tests has allowed LEP physicists to determine unequivocally the number of fundamental 'generations' of elementary particles. These tests also allowed physicists to ascertain the mass of the top quark in advance of its discovery. Recent increases in the accelerator's energy allow new measurements to be undertaken, measurements that may uncover directly or indirectly the long-sought Higgs particle, believed to impart mass to all other particles.

  5. Modified SPC for short run test and measurement process in multi-stations

    Science.gov (United States)

    Koh, C. K.; Chin, J. F.; Kamaruddin, S.

    2018-03-01

    Due to short production runs and measurement error inherent in electronic test and measurement (T&M) processes, continuous quality monitoring through real-time statistical process control (SPC) is challenging. Industry practice allows the installation of guard band using measurement uncertainty to reduce the width of acceptance limit, as an indirect way to compensate the measurement errors. This paper presents a new SPC model combining modified guard band and control charts (\\bar{\\text{Z}} chart and W chart) for short runs in T&M process in multi-stations. The proposed model standardizes the observed value with measurement target (T) and rationed measurement uncertainty (U). S-factor (S f) is introduced to the control limits to improve the sensitivity in detecting small shifts. The model was embedded in automated quality control system and verified with a case study in real industry.

  6. Evaluation of Suitability of Non-Standardized Test Block for Ultrasonic Testing

    International Nuclear Information System (INIS)

    Kwon, Ho Young; Lim, Jong Ho; Kang, Sei Sun

    2000-01-01

    Standard Test Block(STB) for UT(Ultrasonic Testing) is a block approved by authoritative for material, shape and quality. STB is used for characteristic tests, sensitivity calibration and control of the time base range of UT inspection devices. The material, size and chemical components of STB should be strictly controlled to meet the related standards such as ASTM and JIS because it has an effect upon sensitivity, resolution and reproductivity of UT. The STBs which are not approved are sometimes used because the qualified STBs are very expensive. So, the purpose of this study is to survey the characteristics, quality and usability of Non-Standardized Test Blocks. Non-Standardized Test Blocks did not meet the standard requirements in size or chemical components, and ultrasonic characteristics. Therefore if the Non-Standardized Test Blocks are used without being tested, it's likely to cause errors in detecting the location and measuring the size of the defects

  7. Development of the Portuguese version of a standardized reading test: the Radner-Coimbra Charts

    Directory of Open Access Journals (Sweden)

    Andreia Martins Rosa

    Full Text Available ABSTRACT Purpose: To develop 27 short sentence optotypes for the Portuguese version of the Radner Reading Charts. Methods: Thirty-four Portuguese sentences were constructed following the concept of the Radner Reading Charts to obtain highly comparable sentences in terms of lexical difficulty, syntactical complexity, word length, number of syllables, and position of words. A long text (106 words at the 5th grade reading level was also tested to assess the validity of the reading speeds obtained with the short sentences. The short sentences and long text were tested in 50 volunteers with similar educational backgrounds (mean age 30.98 years ± 6.99 years, range 19-47 years. Reading speeds were measured with a stop-watch and reported as words per minute (wpm. The reading time for each of the short sentences to be selected for the chart was defined as falling within the range of the mean ± 0.40 × standard deviation (SD. Results: The overall mean reading speed for each of the short sentences was 235.43 ± 36.39 wpm. The 27 sentences with a mean between 220.8 and 250.0 wpm (overall mean ± 0.40 × SD were selected for construction of the reading charts. The mean reading speed for the long text was 212.42 ± 26.20 wpm. Correlation between the selected short sentences and long text was high (r =0.86. Reliability analysis yielded an overall Cronbach's alpha coefficient of 0.97. Conclusions: The 27 short Portuguese sentences were highly comparable in terms of syntactical structure, number, position and length of words, lexical difficulty, and reading length. This reading test can overcome the limitations of the current tests for homogeneity and comparability, reducing subjectivity in the evaluation of the functional outcomes of medical and surgical ophthalmologic treatments.

  8. Standard Guide for Testing Polymer Matrix Composite Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This guide summarizes the application of ASTM standard test methods (and other supporting standards) to continuous-fiber reinforced polymer matrix composite materials. The most commonly used or most applicable ASTM standards are included, emphasizing use of standards of Committee D30 on Composite Materials. 1.2 This guide does not cover all possible standards that could apply to polymer matrix composites and restricts discussion to the documented scope. Commonly used but non-standard industry extensions of test method scopes, such as application of static test methods to fatigue testing, are not discussed. A more complete summary of general composite testing standards, including non-ASTM test methods, is included in the Composite Materials Handbook (MIL-HDBK-17). Additional specific recommendations for testing textile (fabric, braided) composites are contained in Guide D6856. 1.3 This guide does not specify a system of measurement; the systems specified within each of the referenced standards shall appl...

  9. Neutron Sources for Standard-Based Testing

    Energy Technology Data Exchange (ETDEWEB)

    Radev, Radoslav [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); McLean, Thomas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-11-10

    The DHS TC Standards and the consensus ANSI Standards use 252Cf as the neutron source for performance testing because its energy spectrum is similar to the 235U and 239Pu fission sources used in nuclear weapons. An emission rate of 20,000 ± 20% neutrons per second is used for testing of the radiological requirements both in the ANSI standards and the TCS. Determination of the accurate neutron emission rate of the test source is important for maintaining consistency and agreement between testing results obtained at different testing facilities. Several characteristics in the manufacture and the decay of the source need to be understood and accounted for in order to make an accurate measurement of the performance of the neutron detection instrument. Additionally, neutron response characteristics of the particular instrument need to be known and taken into account as well as neutron scattering in the testing environment.

  10. Tests on standard concrete samples

    CERN Multimedia

    CERN PhotoLab

    1973-01-01

    Compression and tensile tests on standard concrete samples. The use of centrifugal force in tensile testing has been developed by the SB Division and the instruments were built in the Central workshops.

  11. Standardizing the performance evaluation of short-term wind prediction models

    DEFF Research Database (Denmark)

    Madsen, Henrik; Pinson, Pierre; Kariniotakis, G.

    2005-01-01

    Short-term wind power prediction is a primary requirement for efficient large-scale integration of wind generation in power systems and electricity markets. The choice of an appropriate prediction model among the numerous available models is not trivial, and has to be based on an objective...... evaluation of model performance. This paper proposes a standardized protocol for the evaluation of short-term wind-poser preciction systems. A number of reference prediction models are also described, and their use for performance comparison is analysed. The use of the protocol is demonstrated using results...... from both on-shore and off-shore wind forms. The work was developed in the frame of the Anemos project (EU R&D project) where the protocol has been used to evaluate more than 10 prediction systems....

  12. Approaching Repetitive Short Circuit Tests on MW-Scale Power Modules by means of an Automatic Testing Setup

    DEFF Research Database (Denmark)

    Reigosa, Paula Diaz; Wang, Huai; Iannuzzo, Francesco

    2016-01-01

    An automatic testing system to perform repetitive short-circuit tests on megawatt-scale IGBT power modules is pre-sented and described in this paper, pointing out the advantages and features of such testing approach. The developed system is based on a non-destructive short-circuit tester, which has...

  13. Standard test method for dynamic tear testing of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1983-01-01

    1.1 This test method covers the dynamic tear (DT) test using specimens that are 3/16 in. to 5/8 in. (5 mm to 16 mm) inclusive in thickness. 1.2 This test method is applicable to materials with a minimum thickness of 3/16 in. (5 mm). 1.3 The pressed-knife procedure described for sharpening the notch tip generally limits this test method to materials with a hardness level less than 36 HRC. Note 1—The designation 36 HRC is a Rockwell hardness number of 36 on Rockwell C scale as defined in Test Methods E 18. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  14. Testing the standard model

    International Nuclear Information System (INIS)

    Gordon, H.; Marciano, W.; Williams, H.H.

    1982-01-01

    We summarize here the results of the standard model group which has studied the ways in which different facilities may be used to test in detail what we now call the standard model, that is SU/sub c/(3) x SU(2) x U(1). The topics considered are: W +- , Z 0 mass, width; sin 2 theta/sub W/ and neutral current couplings; W + W - , Wγ; Higgs; QCD; toponium and naked quarks; glueballs; mixing angles; and heavy ions

  15. Standardized Testing and the Construction of Governable Persons

    Science.gov (United States)

    Graham, Cameron; Neu, Dean

    2004-01-01

    While debates over standardized testing are ubiquitous, there has been relatively little consideration of how today's standardized testing practices have arisen. The current study provides a chronology of standardized testing within Alberta, Canada. Starting from prior work by Foucault and others on "governmentality", we propose that the…

  16. Comparison of test protocols for standard room/corner tests

    Science.gov (United States)

    R. H. White; M. A. Dietenberger; H. Tran; O. Grexa; L. Richardson; K. Sumathipala; M. Janssens

    1998-01-01

    As part of international efforts to evaluate alternative reaction-to-fire tests, several series of room/comer tests have been conducted. This paper reviews the overall results of related projects in which different test protocols for standard room/corner tests were used. Differences in the test protocols involved two options for the ignition burner scenario and whether...

  17. Prospective testing of Coulomb short-term earthquake forecasts

    Science.gov (United States)

    Jackson, D. D.; Kagan, Y. Y.; Schorlemmer, D.; Zechar, J. D.; Wang, Q.; Wong, K.

    2009-12-01

    Earthquake induced Coulomb stresses, whether static or dynamic, suddenly change the probability of future earthquakes. Models to estimate stress and the resulting seismicity changes could help to illuminate earthquake physics and guide appropriate precautionary response. But do these models have improved forecasting power compared to empirical statistical models? The best answer lies in prospective testing in which a fully specified model, with no subsequent parameter adjustments, is evaluated against future earthquakes. The Center of Study of Earthquake Predictability (CSEP) facilitates such prospective testing of earthquake forecasts, including several short term forecasts. Formulating Coulomb stress models for formal testing involves several practical problems, mostly shared with other short-term models. First, earthquake probabilities must be calculated after each “perpetrator” earthquake but before the triggered earthquakes, or “victims”. The time interval between a perpetrator and its victims may be very short, as characterized by the Omori law for aftershocks. CSEP evaluates short term models daily, and allows daily updates of the models. However, lots can happen in a day. An alternative is to test and update models on the occurrence of each earthquake over a certain magnitude. To make such updates rapidly enough and to qualify as prospective, earthquake focal mechanisms, slip distributions, stress patterns, and earthquake probabilities would have to be made by computer without human intervention. This scheme would be more appropriate for evaluating scientific ideas, but it may be less useful for practical applications than daily updates. Second, triggered earthquakes are imperfectly recorded following larger events because their seismic waves are buried in the coda of the earlier event. To solve this problem, testing methods need to allow for “censoring” of early aftershock data, and a quantitative model for detection threshold as a function of

  18. Potential Bone to Implant Contact Area of Short Versus Standard Implants: An In Vitro Micro-Computed Tomography Analysis.

    Science.gov (United States)

    Quaranta, Alessandro; DʼIsidoro, Orlando; Bambini, Fabrizio; Putignano, Angelo

    2016-02-01

    To compare the available potential bone-implant contact (PBIC) area of standard and short dental implants by micro-computed tomography (μCT) assessment. Three short implants with different diameters (4.5 × 6 mm, 4.1 × 7 mm, and 4.1 × 6 mm) and 2 standard implants (3.5 × 10 mm and 3.3 × 9 mm) with diverse design and surface features were scanned with μCT. Cross-sectional images were obtained. Image data were manually processed to find the plane that corresponds to the most coronal contact point between the crestal bone and implant. The available PBIC was calculated for each sample. Later on, the cross-sectional slices were processed by a 3-dimensional (3D) software, and 3D images of each sample were used for descriptive analysis and display the microtopography and macrotopography. The wide-diameter short implant (4.5 × 6 mm) showed the higher PBIC (210.89 mm) value followed by the standard (178.07 mm and 185.37 mm) and short implants (130.70 mm and 110.70 mm). Wide-diameter short implants show a surface area comparable with standard implants. Micro-CT analysis is a promising technique to evaluate surface area in dental implants with different macrodesign, microdesign, and surface features.

  19. LS1 Report: short-circuit tests

    CERN Multimedia

    Katarina Anthony

    2014-01-01

    As the LS1 draws to an end, teams move from installation projects to a phase of intense testing. Among these are the so-called 'short-circuit tests'. Currently under way at Point 7, these tests verify the cables, the interlocks, the energy extraction systems, the power converters that provide current to the superconducting magnets and the cooling system.   Thermal camera images taken during tests at point 4 (IP4). Before putting beam into the LHC, all of the machine's hardware components need to be put to the test. Out of these, the most complicated are the superconducting circuits, which have a myriad of different failure modes with interlock and control systems. While these will be tested at cold - during powering tests to be done in August - work can still be done beforehand. "While the circuits in the magnets themselves cannot be tested at warm, what we can do is verify the power converter and the circuits right up to the place the cables go into the magn...

  20. Standard test method for guided bend test for ductility of welds

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers a guided bend test for the determination of soundness and ductility of welds in ferrous and nonferrous products. Defects, not shown by X rays, may appear in the surface of a specimen when it is subjected to progressive localized overstressing. This guided bend test has been developed primarily for plates and is not intended to be substituted for other methods of bend testing. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. Note 1—For additional information see Terminology E 6, and American Welding Society Standard D 1.1. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  1. Standard test method for drop-weight tear tests of ferritic steels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This test method covers drop-weight tear tests (DWTT) on ferritic steels with thicknesses between 3.18 and 19.1 mm. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  3. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  4. Standard Test Methods for Wet Insulation Integrity Testing of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 These test methods provide procedures to determine the insulation resistance of a photovoltaic (PV) module, i.e. the electrical resistance between the module's internal electrical components and its exposed, electrically conductive, non-current carrying parts and surfaces. 1.2 The insulation integrity procedures are a combination of wet insulation resistance and wet dielectric voltage withstand test procedures. 1.3 These procedures are similar to and reference the insulation integrity test procedures described in Test Methods E 1462, with the difference being that the photovoltaic module under test is immersed in a wetting solution during the procedures. 1.4 These test methods do not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of these test methods. 1.5 The values stated in SI units are to be regarded as the standard. 1.6 There is no similar or equivalent ISO standard. 1.7 This standard does not purport to address all of the safety conce...

  5. Characterization of new eye drops with choline salicylate and assessment of their irritancy by in vitro short time exposure tests.

    Science.gov (United States)

    Wroblewska, Katarzyna; Kucinska, Małgorzata; Murias, Marek; Lulek, Janina

    2015-09-01

    The aim of our study was to examine the irritation potential of new eye drops containing 2% choline salicylate (CS) as an active pharmaceutical ingredient (API) and various polymers increasing eye drop viscosity (hydroxyethylcellulose, hydroxypropyl methylcellulose, methylcellulose, polyvinyl alcohol, polyvinylpyrrolidone). The standard method for assessing the potential of irritating substances has been the Draize rabbit eye test. However the European Centre for Validation of Alternative Methods and the Coordinating Committee for Validation of Alternative Methods recommend, short time exposure (STE) in vitro tests as an alternative method for assessing eye irritation. The eye irritation potential was determined using cytotoxicity test methods for rabbit corneal cell line (SIRC) after 5 min exposure. The viability of cells was determined using two cytotoxicity assays: MTT and Neutral Red Uptake. According to the irritation rankings for the short time exposure test, all tested eye drops are classified as non-irritating (cell viability >70%).

  6. High flux materials testing reactor HFR Petten. Characteristics of facilities and standard irradiation devices

    International Nuclear Information System (INIS)

    Roettger, H.; Hardt, P. von der; Tas, A.; Voorbraak, W.P.

    1981-01-01

    For the materials testing reactor HFR some characteristic information is presented. Besides the nuclear data for the experiment positions short descriptions are given of the most important standard facilities for material irradiation and radionuclide production. One paragraph deals with the experimental set-ups for solid state and nuclear structure investigations. The information in this report refers to a core type, which is operational since March 1977. The numerical data compiled have been up-dated to January 1981

  7. Short dental implants versus standard dental implants placed in the posterior jaws: A systematic review and meta-analysis.

    Science.gov (United States)

    Lemos, Cleidiel Aparecido Araujo; Ferro-Alves, Marcio Luiz; Okamoto, Roberta; Mendonça, Marcos Rogério; Pellizzer, Eduardo Piza

    2016-04-01

    The purpose of the present systematic review and meta-analysis was to compare short implants (equal or less than 8mm) versus standard implants (larger than 8mm) placed in posterior regions of maxilla and mandible, evaluating survival rates of implants, marginal bone loss, complications and prosthesis failures. This review has been registered at PROSPERO under the number CRD42015016588. Main search terms were used in combination: dental implant, short implant, short dental implants, short dental implants posterior, short dental implants maxilla, and short dental implants mandible. An electronic search for data published up until September/2015 was undertaken using the PubMed/Medline, Embase and The Cochrane Library databases. Eligibility criteria included clinical human studies, randomized controlled trials and/or prospective studies, which evaluated short implants in comparison to standard implants in the same study. The search identified 1460 references, after inclusion criteria 13 studies were assessed for eligibility. A total of 1269 patients, who had received a total of 2631 dental implants. The results showed that there was no significant difference of implants survival (P=.24; RR:1.35; CI: 0.82-2.22), marginal bone loss (P=.06; MD: -0.20; CI: -0.41 to 0.00), complications (P=.08; RR:0.54; CI: 0.27-1.09) and prosthesis failures (P=.92; RR:0.96; CI: 0.44-2.09). Short implants are considered a predictable treatment for posterior jaws. However, short implants with length less than 8 mm (4-7 mm) should be used with caution because they present greater risks to failures compared to standard implants. Short implants are frequently placed in the posterior area in order to avoid complementary surgical procedures. However, clinicians need to be aware that short implants with length less than 8mm present greater risk of failures. Copyright © 2016. Published by Elsevier Ltd.

  8. A standard for test reliability in group research.

    Science.gov (United States)

    Ellis, Jules L

    2013-03-01

    Many authors adhere to the rule that test reliabilities should be at least .70 or .80 in group research. This article introduces a new standard according to which reliabilities can be evaluated. This standard is based on the costs or time of the experiment and of administering the test. For example, if test administration costs are 7 % of the total experimental costs, the efficient value of the reliability is .93. If the actual reliability of a test is equal to this efficient reliability, the test size maximizes the statistical power of the experiment, given the costs. As a standard in experimental research, it is proposed that the reliability of the dependent variable be close to the efficient reliability. Adhering to this standard will enhance the statistical power and reduce the costs of experiments.

  9. Use of short-term test systems for the prediction of the hazard represented by potential chemical carcinogens

    Energy Technology Data Exchange (ETDEWEB)

    Glass, L.R.; Jones, T.D.; Easterly, C.E.; Walsh, P.J.

    1990-10-01

    It has been hypothesized that results from short-term bioassays will ultimately provide information that will be useful for human health hazard assessment. Historically, the validity of the short-term tests has been assessed using the framework of the epidemiologic/medical screens. In this context, the results of the carcinogen (long-term) bioassay is generally used as the standard. However, this approach is widely recognized as being biased and, because it employs qualitative data, cannot be used to assist in isolating those compounds which may represent a more significant toxicologic hazard than others. In contrast, the goal of this research is to address the problem of evaluating the utility of the short-term tests for hazard assessment using an alternative method of investigation. Chemicals were selected mostly from the list of carcinogens published by the International Agency for Research on Carcinogens (IARC); a few other chemicals commonly recognized as hazardous were included. Tumorigenicity and mutagenicity data on 52 chemicals were obtained from the Registry of Toxic Effects of Chemical Substances (RTECS) and were analyzed using a relative potency approach. The data were evaluated in a format which allowed for a comparison of the ranking of the mutagenic relative potencies of the compounds (as estimated using short-term data) vs. the ranking of the tumorigenic relative potencies (as estimated from the chronic bioassays). Although this was a preliminary investigation, it offers evidence that the short-term tests systems may be of utility in ranking the hazards represented by chemicals which may contribute to increased carcinogenesis in humans as a result of occupational or environmental exposures. 177 refs., 8 tabs.

  10. Use of short-term test systems for the prediction of the hazard represented by potential chemical carcinogens

    International Nuclear Information System (INIS)

    Glass, L.R.; Jones, T.D.; Easterly, C.E.; Walsh, P.J.

    1990-10-01

    It has been hypothesized that results from short-term bioassays will ultimately provide information that will be useful for human health hazard assessment. Historically, the validity of the short-term tests has been assessed using the framework of the epidemiologic/medical screens. In this context, the results of the carcinogen (long-term) bioassay is generally used as the standard. However, this approach is widely recognized as being biased and, because it employs qualitative data, cannot be used to assist in isolating those compounds which may represent a more significant toxicologic hazard than others. In contrast, the goal of this research is to address the problem of evaluating the utility of the short-term tests for hazard assessment using an alternative method of investigation. Chemicals were selected mostly from the list of carcinogens published by the International Agency for Research on Carcinogens (IARC); a few other chemicals commonly recognized as hazardous were included. Tumorigenicity and mutagenicity data on 52 chemicals were obtained from the Registry of Toxic Effects of Chemical Substances (RTECS) and were analyzed using a relative potency approach. The data were evaluated in a format which allowed for a comparison of the ranking of the mutagenic relative potencies of the compounds (as estimated using short-term data) vs. the ranking of the tumorigenic relative potencies (as estimated from the chronic bioassays). Although this was a preliminary investigation, it offers evidence that the short-term tests systems may be of utility in ranking the hazards represented by chemicals which may contribute to increased carcinogenesis in humans as a result of occupational or environmental exposures. 177 refs., 8 tabs

  11. Standard Test Method for Wet Insulation Integrity Testing of Photovoltaic Arrays

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers a procedure to determine the insulation resistance of a photovoltaic (PV) array (or its component strings), that is, the electrical resistance between the array's internal electrical components and is exposed, electrically conductive, non-current carrying parts and surfaces of the array. 1.2 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  12. Economics from a Different Point of View − Good Practice in Teacher Training: How to Handle, Use and Judge External Standardized Tests in Schools

    Directory of Open Access Journals (Sweden)

    Julia Claire Prieß-Buchheit

    2016-02-01

    Full Text Available The Economic Actions in Education training module (EAE teaches how to handle, use and judge external standardized tests in schools. The EAE programme was implemented in teacher training at the University of Kiel, because teachers are increasingly under external scrutiny and are being held accountable for student and school achievements. The EAE programme includes a reader (in English, through which prospective teachers understand and analyze core terms of the field. Furthermore, different didactical methods such as think-pair-share, role play and short lectures provide a group dynamic in which students gain an insight into standardized tests at a macro level. Students learn what is involved in standardized tests and they develop the ability to make a critical judgement about how they will use or refuse standardized tests in schools. EAE enables teachers to use standardized tests for curriculum and instruction improvement as well as refuse standardized tests to highlight autonomous teaching and decline governance from outside.

  13. The sensitivity testing of Wilms' tumors to cytostatic agents with an autoradiographic in vitro short-term test

    International Nuclear Information System (INIS)

    Willnow, U.

    1984-01-01

    Sensitivity of 15 Wilms' tumors in children was tested towards cytostatic agents in vitro by means of an autoradiographic short-term test. Sensitivity was measured as the magnitude of the inhibition of 3 H-thymidine or 3 H-uridine incorporation. The test was performed with Adriamycin, Actinomycin D, Daunomycin, Bleomycin, Cyclophosphamide, Ifosfamide, Trenimon, and Arabinosylcytosine. None of the tumors is resistant to all substances, they are responsive against 2 or more drugs. The most effective drugs tested are Adriamycin, Actinomycin D and Cyclophosphamide. The tumors show a marked individual sensitivity pattern. This behavior is explained mainly by the usually high proliferative activity of Wilms' tumors. The possibilities and limits of long-term and short-term methods for sensitivity testing are discussed critically. For the evaluation of the results of in vitro testing and in vivo effectiveness the close correlation should be considered between the type of cytostatic agent and proliferation kinetics of the tumor, cytostatic agent and effect on tumor metabolism as well as the effect of the cytostatics and the nucleic acid precursors used for the short-term test. Despite the methodological limitations preclinical testing should be preferred to unselected chemotherapy. (author)

  14. The first DC performance test and analysis of CC conductor short sample at ASIPP conductor test facility

    International Nuclear Information System (INIS)

    Shi Yi; Wu Yu; Liu Huajun; Long Feng; Qian Li; Ren Zhibin; Li Shaolei; Liu Bo; Chen Jinglin

    2012-01-01

    Highlights: ► In this study the first DC performance experiments of ITER correction coil conductor short sample have been carried out in ASIPP test facility. ► A CC conductor short sample was fabricated and tested to confirm the capability of this test facility for qualification tests of CC conductors. ► There is no obvious impact of cycling on DC performance measurement. ► Those measured results of current sharing temperature are in agreement with the expected results from strand scaling - Abstract: The first DC performance experiments of ITER correction coil (CC) conductor short sample have been carried out in the conductor test facility of Institute of Plasma Physics, CAS (ASIPP) in January this year. Those experiments aim to investigate the DC performance of ITER CC conductor. The tested conductor short sample is bended as a half circle with the diameter of 270 mm to meet the background magnetic field shape. The half circle part of sample is longer than the final twist pitch. The current sharing temperature (T cs ) in the 3.86 T external magnetic field (B ex ), ≤12 kA could be measured including the critical current (I c ) run. There is no obvious impact of 1000 cycles on DC performance. Those measured T cs results are in agreement with the expected results from strand scaling.

  15. Effects of Repeated Testing on Short- and Long-Term Memory Performance across Different Test Formats

    Science.gov (United States)

    Stenlund, Tova; Sundström, Anna; Jonsson, Bert

    2016-01-01

    This study examined whether practice testing with short-answer (SA) items benefits learning over time compared to practice testing with multiple-choice (MC) items, and rereading the material. More specifically, the aim was to test the hypotheses of "retrieval effort" and "transfer appropriate processing" by comparing retention…

  16. Non-destructive testing. The current state of standards and qualification and certification for leak testing

    International Nuclear Information System (INIS)

    Tamura, Yoshikazu

    2011-01-01

    Domestic standards of the leak testing are enacted as one of Japan Industrial Standards. The conformity is advanced between these domestic standards and ISO (International Organization for Standardization) standard. ISO9712 (Non-destructive testing-Qualification and certification of personnel) was revised to include the leak testing of qualification and certification in 2005. The preparation working group of qualification and certification for leak testing is planning start aiming at the system in one and a half years. (author)

  17. Standard Test Method for Testing Nonmetallic Seal Materials by Immersion in a Simulated Geothermal Test Fluid

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This test method covers a procedure for a laboratory test for performing an initial evaluation (screening) of nonmetallic seal materials by immersion in a simulated geothermal test fluid. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 6 and 11.7.

  18. Standard Test Method for Hydrophobic Surface Films by the Atomizer Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1965-01-01

    1.1 This test method covers the detection of the presence of hydrophobic (nonwetting) films on surfaces and the presence of hydrophobic organic materials in processing ambients. When properly conducted, the test will enable detection of fractional molecular layers of hydrophobic organic contaminants. On very rough or porous surfaces the sensitivity of the test may be significantly decreased. 1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. Standard test method for tension testing of structural alloys in liquid helium

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method describes procedures for the tension testing of structural alloys in liquid helium. The format is similar to that of other ASTM tension test standards, but the contents include modifications for cryogenic testing which requires special apparatus, smaller specimens, and concern for serrated yielding, adiabatic heating, and strain-rate effects. 1.2 To conduct a tension test by this standard, the specimen in a cryostat is fully submerged in normal liquid helium (He I) and tested using crosshead displacement control at a nominal strain rate of 10−3 s−1 or less. Tests using force control or high strain rates are not considered. 1.3 This standard specifies methods for the measurement of yield strength, tensile strength, elongation, and reduction of area. The determination of the elastic modulus is treated in Test Method E 111. Note 1—The boiling point of normal liquid helium (He I) at sea level is 4.2 K (−269°C or −452.1°F or 7.6°R). It decreases with geographic elevation and is...

  20. Standard practice for modified salt spray (fog) testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This practice covers and sets forth conditions for five modifications in salt spray (fog) testing for specification purposes. These are in chronological order of their development: 1.1.1 Annex A1, acetic acid-salt spray test, continuous. 1.1.2 Annex A2, cyclic acidified salt spray test. 1.1.3 Annex A3, seawater acidified test, cyclic (SWAAT). 1.1.4 Annex A4, SO2 salt spray test, cyclic. 1.1.5 Annex A5, dilute electrolyte cyclic fog dry test. 1.2 This practice does not prescribe the type of modification, test specimen or exposure periods to be used for a specific product, nor the interpretation to be given to the results. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to consult and establish appropriate safety and health practices and determine the applicabilit...

  1. Standards for educational and psychological testing

    CERN Document Server

    2014-01-01

    Developed jointly by the American Educational Research Association, American Psychological Association, and the National Council on Measurement in Education, Standards for Educational and Psychological Testing (Revised 2014) addresses professional and technical issues of test development and use in education, psychology, and employment. It includes changes in federal law and measurement trends affecting validity, testing individuals with disabilities or different linguistic backgrounds, and new types of tests, as well as new uses of existing tests.

  2. The skin prick test – European standards

    Directory of Open Access Journals (Sweden)

    Heinzerling Lucie

    2013-02-01

    Full Text Available Abstract Skin prick testing is an essential test procedure to confirm sensitization in IgE-mediated allergic disease in subjects with rhinoconjunctivitis, asthma, urticaria, anapylaxis, atopic eczema and food and drug allergy. This manuscript reviews the available evidence including Medline and Embase searches, abstracts of international allergy meetings and position papers from the world allergy literature. The recommended method of prick testing includes the appropriate use of specific allergen extracts, positive and negative controls, interpretation of the tests after 15 – 20 minutes of application, with a positive result defined as a wheal ≥3 mm diameter. A standard prick test panel for Europe for inhalants is proposed and includes hazel (Corylus avellana, alder (Alnus incana, birch (Betula alba, plane (Platanus vulgaris, cypress (Cupressus sempervirens, grass mix (Poa pratensis, Dactilis glomerata, Lolium perenne, Phleum pratense, Festuca pratensis, Helictotrichon pretense, Olive (Olea europaea, mugwort (Artemisia vulgaris, ragweed (Ambrosia artemisiifolia, Alternaria alternata (tenuis, Cladosporium herbarum, Aspergillus fumigatus, Parietaria, cat, dog, Dermatophagoides pteronyssinus, Dermatophagoides farinae, and cockroach (Blatella germanica. Standardization of the skin test procedures and standard panels for different geographic locations are encouraged worldwide to permit better comparisons for diagnostic, clinical and research purposes.

  3. Standard specification for agencies performing nondestructive testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This specification covers minimum requirements for agencies performing nondestructive testing (NDT). 1.2 When using this specification to assess the capability of, or to accredit NDT agencies, Guide E 1359 shall be used as a basis for the survey. It can be supplemented as necessary with more detail in order to meet the auditor's specific needs. 1.3 This specification can be used as a basis to evaluate testing or inspection agencies, or both, and is intended for use for the qualifying or accrediting, or both, of testing or inspection agencies, public or private. 1.4 The use of SI or inch-pound units, or combination thereof, will be the responsibility of the technical committee whose standards are referred to in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to...

  4. Standard test methods for elevated temperature tension tests of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods cover procedure and equipment for the determination of tensile strength, yield strength, elongation, and reduction of area of metallic materials at elevated temperatures. 1.2 Determination of modulus of elasticity and proportional limit are not included. 1.3 Tension tests under conditions of rapid heating or rapid strain rates are not included. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Is the standard model really tested?

    International Nuclear Information System (INIS)

    Takasugi, E.

    1989-01-01

    It is discussed how the standard model is really tested. Among various tests, I concentrate on the CP violation phenomena in K and B meson system. Especially, the resent hope to overcome the theoretical uncertainty in the evaluation on the CP violation of K meson system is discussed. (author)

  6. Standard Ship Test and Inspection Plan, Procedures and Database

    National Research Council Canada - National Science Library

    1999-01-01

    ... construction schedules and increased cost is the area of test and inspection. This project investigates existing rules and regulations for testing and inspection of commercial ships and identifies differences and similarities within the requirements. The results include comparison matrices, a standard test plan, a set of standard test procedures, and a sample test database developed for a typical commercial ship.

  7. Standard test method for determining susceptibility to stress-corrosion cracking of 2XXX and 7XXX Aluminum alloy products

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1998-01-01

    1.1 This test method covers a uniform procedure for characterizing the resistance to stress-corrosion cracking (SCC) of high-strength aluminum alloy wrought products for the guidance of those who perform stress-corrosion tests, for those who prepare stress-corrosion specifications, and for materials engineers. 1.2 This test method covers method of sampling, type of specimen, specimen preparation, test environment, and method of exposure for determining the susceptibility to SCC of 2XXX (with 1.8 to 7.0 % copper) and 7XXX (with 0.4 to 2.8 % copper) aluminum alloy products, particularly when stressed in the short-transverse direction relative to the grain structure. 1.3 The values stated in SI units are to be regarded as standard. The inch-pound units in parentheses are provided for information. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and de...

  8. Standard test method for galling resistance of material couples

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers a laboratory test that ranks the galling resistance of material couples using a quantitative measure. Bare metals, alloys, nonmetallic materials, coatings, and surface modified materials may be evaluated by this test method. 1.2 This test method is not designed for evaluating the galling resistance of material couples sliding under lubricated conditions, because galling usually will not occur under lubricated sliding conditions using this test method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  9. Standard test methods for characterizing duplex grain sizes

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 These test methods provide simple guidelines for deciding whether a duplex grain size exists. The test methods separate duplex grain sizes into one of two distinct classes, then into specific types within those classes, and provide systems for grain size characterization of each type. 1.2 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns associated with its use. It is the responsibility of the user of this standard to consult appropriate safety and health practices and determine the applicability of regulatory limitations prior to its use.

  10. Cross-cultural adaptation of the US consumer form of the short Primary Care Assessment Tool (PCAT): the Korean consumer form of the short PCAT (KC PCAT) and the Korean standard form of the short PCAT (KS PCAT).

    Science.gov (United States)

    Jeon, Ki-Yeob

    2011-01-01

    It is well known that countries with well-structured primary care have better health outcomes, better health equity and reduced healthcare costs. This study aimed to culturally modify and validate the US consumer form of the short Primary Care Assessment Tool (PCAT) in primary care in the Republic of Korea (hereafter referred to as Korea). The Korean consumer form of the short PCAT (KC PCAT) was cross-culturally modified from the original version using a standardised transcultural adaptation method. A pre-test version of the KC PCAT was formulated by replacement of four items and modification of a further four items from the 37 items of the original consumer form of the short PCAT at face value evaluation meetings. Pilot testing was done with a convenience sample of 15 responders at two different sites. Test-retest showed high reliability. To validate the KC PCAT, 606 clients participated in a survey carried out in Korea between February and May 2006. Internal consistency reliability, test-retest reliability and factor analysis were conducted in order to test validity. Psychometric testing was carried out on 37 items of the KC PCAT to make the KS PCAT which has 30 items and has seven principal domains: first contact utilisation, first contact accessibility, ongoing accountable care (ongoing care and coordinated rapport care), integrated care (patient-centred care with integration between primary and specialty care or between different specialties), comprehensive care, community-oriented care and culturally-oriented care. Component factors of the verified KS PCAT explained 58.28% of the total variance in the total item scores of primary care. The verified KS PCAT has been characterised by the seven classic domains of primary care with minor modifications. This may provide clues concerning differences in expectations for primary care in the Korean population as compared with that of the US. The KS PCAT is a reliable and valid tool for the evaluation of the quality of

  11. Pad-weighing test performed with standardized bladder volume

    DEFF Research Database (Denmark)

    Lose, G; Rosenkilde, P; Gammelgaard, J

    1988-01-01

    The result of the one-hour pad-weighing test proposed by the International Continence Society has been demonstrated to depend on the urine load during the test. To increase reproducibility of the pad-weighing test by minimizing the influence of variation in urine load the test was done with a sta...... to +/- 24 g between two tests. It is concluded that this setup (i.e., standardized bladder volume) of the one-hour pad-weighing test allows for a more reliable assessment of urinary incontinence for quantitative purposes....... with a standardized bladder volume (50% of the cystometric bladder capacity). Twenty-five female patients with stress or mixed incontinence underwent two separate tests. Test-retest results were highly correlated (r = 0.97, p less than 0.001). Nonetheless, analysis of test-retest differences revealed a variation up...

  12. Standard Test Method for Hydrophobic Surface Films by the Water-Break Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the detection of the presence of hydrophobic (nonwetting) films on surfaces and the presence of hydrophobic organic materials in processing ambients. When properly conducted, the test will enable detection of molecular layers of hydrophobic organic contaminants. On very rough or porous surfaces, the sensitivity of the test may be significantly decreased. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  13. 42 CFR 493.1281 - Standard: Comparison of test results.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Comparison of test results. 493.1281 Section 493.1281 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... Testing Analytic Systems § 493.1281 Standard: Comparison of test results. (a) If a laboratory performs the...

  14. Standard leach tests for nuclear waste materials

    International Nuclear Information System (INIS)

    Strachan, D.M.; Barnes, B.O.; Turcotte, R.P.

    1980-01-01

    Five leach tests were conducted to study time-dependent leaching of waste forms (glass). The first four tests include temperature as a variable and the use of three standard leachants. Three of the tests are static and two are dynamic (flow). This paper discusses the waste-form leach tests and presents some representative data. 4 figures

  15. Cognitive Fatigue Influences Students’ Performance on Standardized Tests

    DEFF Research Database (Denmark)

    Sievertsen, Hans Henrik; Gino, Francesca; Piovesan, Marco

    2016-01-01

    We identify one potential source of bias that influences children’s performance on standardized tests and that is predictable based on psychological theory: the time at which students take the test. Using test data for all children attending Danish public schools between school years 2009....../10 and 2012/13, we find that, for every hour later in the day, test scores decrease by 0.9% of an SD. In addition, a 20- to 30-minute break improves average test scores. Time of day affects students’ test performance because, over the course of a regular day, students’ mental resources get taxed. Thus......, as the day wears on, students become increasingly fatigued and consequently more likely to underperform on a standardized test....

  16. Mechanical Testing of Polymeric Composites for Aircraft Applications: Standards, Requirements and Limitations

    Science.gov (United States)

    Chinchan, Levon; Shevtsov, Sergey; Soloviev, Arcady; Shevtsova, Varvara; Huang, Jiun-Ping

    The high-loaded parts of modern aircrafts and helicopters are often produced from polymeric composite materials. Such materials consist of reinforcing fibers, packed by layers with the different angles, and resin, which uniformly distributes the structural stresses between fibers. These composites should have an orthotropic symmetry of mechanical properties to obtain the desirable spatial distribution of elastic moduli consistent to the external loading pattern. Main requirements to the aircraft composite materials are the specified elastic properties (9 for orthotropic composite), long-term strength parameters, high resistance against the environmental influences, low thermal expansion to maintain the shape stability. These properties are ensured by an exact implementation of technological conditions and many testing procedures performed with the fibers, resin, prepregs and ready components. Most important mechanical testing procedures are defined by ASTM, SACMA and other standards. However in each case the wide diversity of components (dimensions and lay-up of fibers, rheological properties of thermosetting resins) requires a specific approach to the sample preparation, testing, and numerical processing of the testing results to obtain the veritable values of tested parameters. We pay the special attention to the cases where the tested specimens are cut not from the plates recommended by standards, but from the ready part manufactured with the specific lay-up, tension forces on the reinforcing fiber at the filament winding, and curing schedule. These tests can provide most useful information both for the composite structural design and to estimate a quality of the ready parts. We consider an influence of relation between specimen dimensions and pattern of the fibers winding (or lay-up) on the results of mechanical testing for determination of longitudinal, transverse and in-plane shear moduli, an original numerical scheme for reconstruction of in-plane shear

  17. Short-term effects of a standardized glucose load on region-specific aortic pulse wave velocity assessed by MRI

    NARCIS (Netherlands)

    Jonker, J.T.; Tjeerdema, N.; Hensen, L.C.; Lamb, H.J.; Romijn, J.A.; Smit, J.W.; Westenberg, J.J.; Roos, A. de

    2014-01-01

    PURPOSE: To assess the short-term effects of a standardized oral glucose load on regional aortic pulse wave velocity (PWV) using two-directional in-plane velocity encoded MRI. MATERIALS AND METHODS: A randomized, controlled intervention was performed in 16 male subjects (mean +/- standard deviation:

  18. The Standardization of Tests: Criteria and Criticisms

    Science.gov (United States)

    Weiner, Paul S.; Hoock, William C.

    1973-01-01

    Following a review of the procedures involved in the establishment of norms for standardized tests, the specific procedures used to establish norms for three tests commonly used in speech and language pathology are critically examined. (LS)

  19. Standard test method for wear testing with a pin-on-disk apparatus

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers a laboratory procedure for determining the wear of materials during sliding using a pin-on-disk apparatus. Materials are tested in pairs under nominally non-abrasive conditions. The principal areas of experimental attention in using this type of apparatus to measure wear are described. The coefficient of friction may also be determined. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  20. 76 FR 74078 - Standard Mail Market Test

    Science.gov (United States)

    2011-11-30

    ... POSTAL REGULATORY COMMISSION [Docket No. MT2011-3; Order No. 998] Standard Mail Market Test AGENCY... Service application for an exemption from the annual revenue limitation that applies to market tests of... limitation in any year during the test of an experimental market dominant product.\\1\\ Pursuant to 39 U.S.C...

  1. Long- and short-term trends in vessel conditioning of TFTR [Tokamak Fusion Test Reactor

    International Nuclear Information System (INIS)

    LaMarche, P.H.; Dylla, H.F.; Bell, M.G.

    1986-10-01

    We have investigated trends in the conditioning of the Tokamak Fusion Test Reactor (TFTR) vacuum vessel during the May 1984 to April 1985 run period. The initial conditioning of the vessel, consisting of glow discharge cleaning (GDC) and pulse discharge cleaning (PDC) in concert with a 150 0 C vessel bakeout, is necessary to assure plasma operation after atmospheric venting. A long-term conditioning process, ascribed to limiter conditioning, effectively improves operational conditions during the course of the run. Over several thousand high power plasma discharges, the improvement was documented by using standard parameter (fiducial) plasma discharges. Several techniques demonstrated short-term improvements in vessel conditioning during this time period, including: Cr gettering and programming the plasma position relative to the limiter contact area

  2. Standardization of waste acceptance test methods by the Materials Characterization Center

    International Nuclear Information System (INIS)

    Slate, S.C.

    1985-01-01

    This paper describes the role of standardized test methods in demonstrating the acceptability of high-level waste (HLW) forms for disposal. Key waste acceptance tests are standardized by the Materials Characterization Center (MCC), which the US Department of Energy (DOE) has established as the central agency in the United States for the standardization of test methods for nuclear waste materials. This paper describes the basic three-step process that is used to show that waste is acceptable for disposal and discusses how standardized tests are used in this process. Several of the key test methods and their areas of application are described. Finally, future plans are discussed for using standardized tests to show waste acceptance. 9 refs., 1 tab

  3. The impact of a standardized program on short and long-term outcomes in bariatric surgery.

    Science.gov (United States)

    Aird, Lisa N F; Hong, Dennis; Gmora, Scott; Breau, Ruth; Anvari, Mehran

    2017-02-01

    The purpose of this study was to determine whether there has been an improvement in short- and long-term clinical outcomes since 2010, when the Ontario Bariatric Network led a province-wide initiative to establish a standardized system of care for bariatric patients. The system includes nine bariatric centers, a centralized referral system, and a research registry. Standardization of procedures has progressed yearly, including guidelines for preoperative assessment and perioperative care. Analysis of the OBN registry data was performed by fiscal year between April 2010 and March 2015. Three-month overall postoperative complication rates and 30 day postoperative mortality were calculated. The mean percentage of weight loss at 1, 2, and 3 years postoperative, and regression of obesity-related diseases were calculated. The analysis of continuous and nominal data was performed using ANOVA, Chi-square, and McNemar's testing. A multiple logistic regression analysis was performed for factors affecting postoperative complication rate. Eight thousand and forty-three patients were included in the bariatric registry between April 2010 and March 2015. Thirty-day mortality was rare (bariatric care has contributed to improvements in complication rates and supported prolonged weight loss and regression of obesity-related diseases in patients undergoing bariatric surgery in Ontario.

  4. A Short Term Analogue Memory

    DEFF Research Database (Denmark)

    Shah, Peter Jivan

    1992-01-01

    A short term analogue memory is described. It is based on a well-known sample-hold topology in which leakage currents have been minimized partly by circuit design and partly by layout techniques. Measurements on a test chip implemented in a standard 2.4 micron analogue CMOS process show a droop...

  5. Study on the testing standards of quality assurance for CT image

    International Nuclear Information System (INIS)

    Liu Jingxin; Yang Haishan; Liu Gang; Wang Liyun

    2000-01-01

    Objective: To establish national testing standards of quality assurance for CT image. Methods: 104 sets of CT system were tested using quality assurance test phantoms and devices including American RMI 461A, RMI 463, MDH 1015 C with ION Chamber, Sweden UNF 9004 kvp meter. These CT were made from different manufacturers including out of date of CT and state-of-art spiral CT system. Thirteen kinds of standards on CT from different countries and 87 sets of technical specifications of CT were collected. The results of the test were compared using phantoms of RMI, Victoreen, Catphan on the same CT system (Siemens HQS). Results: Based on the test results of this study, with reference to the foreign standards and some of regulations in China, CT test items should include high contrast resolution, low contrast resolution, noise, uniformity, mean CT unit, dose slice thickness, localization light, positioning of patient support and gantry tilt. Standards including acceptance test, status test, and constancy test were made in specification. Among them, constancy test equals to IEC 122-2-6; items and results in acceptance test are stricter than in the status test; and low contrast resolution, uniformity, localization light accuracy and positioning of patient support in the acceptance test are even stricter than that in foreign standards. Conclusion: The testing standards of quality assurance for CT developed in this study shows practical and useful in China, which supplemented to the existing international standards

  6. Gas temperature measurements in short duration turbomachinery test facilities

    Science.gov (United States)

    Cattafesta, L. N.; Epstein, A. H.

    1988-07-01

    Thermocouple rakes for use in short-duration turbomachinery test facilities have been developed using very fine thermocouples. Geometry variations were parametrically tested and showed that bare quartz junction supports (76 microns in diameter) yielded superior performance, and were rugged enough to survive considerable impact damage. Using very low cost signal conditioning electronics, temperature accuracies of 0.3 percent were realized yielding turbine efficiency measurements at the 1-percent level. Ongoing work to improve this accuracy is described.

  7. 49 CFR 219.701 - Standards for drug and alcohol testing.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Standards for drug and alcohol testing. 219.701... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Drug and Alcohol Testing Procedures § 219.701 Standards for drug and alcohol testing. (a) Drug testing required or authorized by subparts B...

  8. A comparison of discriminant logistic regression and Item Response Theory Likelihood-Ratio Tests for Differential Item Functioning (IRTLRDIF) in polytomous short tests.

    Science.gov (United States)

    Hidalgo, María D; López-Martínez, María D; Gómez-Benito, Juana; Guilera, Georgina

    2016-01-01

    Short scales are typically used in the social, behavioural and health sciences. This is relevant since test length can influence whether items showing DIF are correctly flagged. This paper compares the relative effectiveness of discriminant logistic regression (DLR) and IRTLRDIF for detecting DIF in polytomous short tests. A simulation study was designed. Test length, sample size, DIF amount and item response categories number were manipulated. Type I error and power were evaluated. IRTLRDIF and DLR yielded Type I error rates close to nominal level in no-DIF conditions. Under DIF conditions, Type I error rates were affected by test length DIF amount, degree of test contamination, sample size and number of item response categories. DLR showed a higher Type I error rate than did IRTLRDIF. Power rates were affected by DIF amount and sample size, but not by test length. DLR achieved higher power rates than did IRTLRDIF in very short tests, although the high Type I error rate involved means that this result cannot be taken into account. Test length had an important impact on the Type I error rate. IRTLRDIF and DLR showed a low power rate in short tests and with small sample sizes.

  9. Validation of a Short Form of an Indecision Test: The Vocational Assessment Test

    Science.gov (United States)

    Picard, France; Frenette, Éric; Guay, Frédéric; Labrosse, Julie

    2015-01-01

    The purpose of this research was to validate the scores of a short form of a new instrument, "l'Épreuve de décision vocationnelle, forme scolaire" (EDV-9S; vocational assessment test), which measures six indecision-related problems (lack of self-knowledge, lack of readiness, lack of method in decision making, lack of information,…

  10. Standards for radiation protection instrumentation: design of safety standards and testing procedures

    International Nuclear Information System (INIS)

    Meissner, Frank

    2008-01-01

    This paper describes by means of examples the role of safety standards for radiation protection and the testing and qualification procedures. The development and qualification of radiation protection instrumentation is a significant part of the work of TUV NORD SysTec, an independent expert organisation in Germany. The German Nuclear Safety Standards Commission (KTA) establishes regulations in the field of nuclear safety. The examples presented may be of importance for governments and nuclear safety authorities, for nuclear operators and for manufacturers worldwide. They demonstrate the advantage of standards in the design of radiation protection instrumentation for new power plants, in the upgrade of existing instrumentation to nuclear safety standards or in the application of safety standards to newly developed equipment. Furthermore, they show how authorities may proceed when safety standards for radiation protection instrumentation are not yet established or require actualization. (author)

  11. Slovak Office of Standards, Metrology and Testing. Annual Report 2001

    International Nuclear Information System (INIS)

    2002-01-01

    A brief account of activities carried out by the Slovak Office of Standards, Metrology and Testing of the Slovak Republic in 2001 is presented. These activities are reported under the headings: (1) Introduction by the President of the Slovak Office of Standards, Metrology and Testing; (2) The Vice-president's Unit Standardization and Quality; (3) The President's Office; (4) Chief Inspector Department; (5) Legislative-juridical Department; (6) Department of Economy; (7) Department of International Co-operation; (8) Department of European Integration; (9) Department of Metrology; (10) Department of Testing; (11) Department of the Cyclotron Centre SR; (12) Slovak Institute of Metrology; (13) Slovak Standards Institution; (14) Slovak Metrology Inspectorate; (15) Slovak Legal Metrology; (16) Measuring Techniques - Technocentre - MTT; Abbreviations; (17) Technical Testing Institute Piestany; (18) Testing Institute of Transport and Earthmoving Machinery - SUDST

  12. Radioactive material package test standards and performance requirements - public perception

    International Nuclear Information System (INIS)

    Pope, R.B.; Shappert, L.B.; Rawl, R.R.

    1992-01-01

    This paper addresses issues related to the public perception of the regulatory test standards and performance requirements for packaging and transporting radioactive material. Specifically, it addresses the adequacy of the package performance standards and testing for Type B packages, which are those packages designed for transporting the most hazardous quantities and forms of radioactive material. Type B packages are designed to withstand accident conditions in transport. To improve public perception, the public needs to better understand: (a) the regulatory standards and requirements themselves, (b) the extensive history underlying their development, and (c) the soundness of the technical foundation. The public needs to be fully informed on studies, tests, and analyses that have been carried out worldwide and form the basis of the regulatory standards and requirements. This paper provides specific information aimed at improving the public perception of packages test standards

  13. Interpreting Results from the Standardized UXO Test Sites

    National Research Council Canada - National Science Library

    May, Michael; Tuley, Michael

    2007-01-01

    ...) and the Environmental Security Technology Certification Program (ESCTP) to complete a detailed analysis of the results of testing carried out at the Standardized Unexploded Ordnance (UXO) Test Sites...

  14. Standard test method for isotopic analysis of uranium hexafluoride by double standard single-collector gas mass spectrometer method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This is a quantitative test method applicable to determining the mass percent of uranium isotopes in uranium hexafluoride (UF6) samples with 235U concentrations between 0.1 and 5.0 mass %. 1.2 This test method may be applicable for the entire range of 235U concentrations for which adequate standards are available. 1.3 This test method is for analysis by a gas magnetic sector mass spectrometer with a single collector using interpolation to determine the isotopic concentration of an unknown sample between two characterized UF6 standards. 1.4 This test method is to replace the existing test method currently published in Test Methods C761 and is used in the nuclear fuel cycle for UF6 isotopic analyses. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro...

  15. DOE standard: Quality assurance inspection and testing of HEPA filters

    International Nuclear Information System (INIS)

    1999-02-01

    This standard establishes essential elements for the quality assurance inspection and testing of HEPA filters by US Department of Energy (DOE)-accepted Filter Test Facilities (FTF). The standard specifies HEPA filter quality assurance inspection and testing practices established in DOE-STD-3022-98, DOE HEPA Filter Test Program, and provides a basis for the preparation of written operating procedures for primary FTF functions

  16. Framework for a Comparative Accelerated Testing Standard for PV Modules: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, S.; Wohlgemuth, J.; Yamamichi, M.; Sample, T.; Miller, D.; Meakin, D.; Monokroussos, C.; TamizhMani, M.; Kempe, M.; Jordan, D.; Bosco, N.; Hacke, P.; Bermudez, V.; Kondo, M.

    2013-08-01

    As the photovoltaic industry has grown, the interest in comparative accelerated testing has also grown. Private test labs offer testing services that apply greater stress than the standard qualification tests as tools for differentiating products and for gaining increased confidence in long-term PV investments. While the value of a single international standard for comparative accelerated testing is widely acknowledged, the development of a consensus is difficult. This paper strives to identify a technical basis for a comparative standard.

  17. Standardized waste form test methods

    International Nuclear Information System (INIS)

    Slate, S.C.

    1984-01-01

    The Materials Characterization Center (MCC) is developing standard tests to characterize nuclear waste forms. Development of the first thirteen tests was originally initiated to provide data to compare different high-level waste (HLW) forms and to characterize their basic performance. The current status of the first thirteen MCC tests and some sample test results are presented: the radiation stability tests (MCC-6 and 12) and the tensile-strength test (MCC-11) are approved; the static leach tests (MCC-1, 2, and 3) are being reviewed for full approval; the thermal stability (MCC-7) and microstructure evaluation (MCC-13) methods are being considered for the first time; and the flowing leach test methods (MCC-4 and 5), the gas generation methods (MCC-8 and 9), and the brittle fracture method (MCC-10) are indefinitely delayed. Sample static leach test data on the ARM-1 approved reference material are presented. Established tests and proposed new tests will be used to meet new testing needs. For waste form production, tests on stability and composition measurement are needed to provide data to ensure waste form quality. In transporation, data are needed to evaluate the effects of accidents on canisterized waste forms. The new MCC-15 accident test method and some data are presented. Compliance testing needs required by the recent draft repository waste acceptance specifications are described. These specifications will control waste form contents, processing, and performance

  18. Standardized waste form test methods

    International Nuclear Information System (INIS)

    Slate, S.C.

    1984-11-01

    The Materials Characterization Center (MCC) is developing standard tests to characterize nuclear waste forms. Development of the first thirteen tests was originally initiated to provide data to compare different high-level waste (HLW) forms and to characterize their basic performance. The current status of the first thirteen MCC tests and some sample test results is presented: The radiation stability tests (MCC-6 and 12) and the tensile-strength test (MCC-11) are approved; the static leach tests (MCC-1, 2, and 3) are being reviewed for full approval; the thermal stability (MCC-7) and microstructure evaluation (MCC-13) methods are being considered for the first time; and the flowing leach tests methods (MCC-4 and 5), the gas generation methods (MCC-8 and 9), and the brittle fracture method (MCC-10) are indefinitely delayed. Sample static leach test data on the ARM-1 approved reference material are presented. Established tests and proposed new tests will be used to meet new testing needs. For waste form production, tests on stability and composition measurement are needed to provide data to ensure waste form quality. In transportation, data are needed to evaluate the effects of accidents on canisterized waste forms. The new MCC-15 accident test method and some data are presented. Compliance testing needs required by the recent draft repository waste acceptance specifications are described. These specifications will control waste form contents, processing, and performance. 2 references, 2 figures

  19. Patch testing with Indian standard series

    Directory of Open Access Journals (Sweden)

    Narendra G

    2002-01-01

    Full Text Available Hundred patients (61 males, 39 females suspected to have allergic contact dermatitis were patch tested with Indian standard series (ISS. Forty four showed one or more positive reactions. The frequent sensitizers observed were nickel sulphate-12 (15%, potassium dichromate-11 (13.75%, cobalt chloride and colophony-7 (8.75% each, fragrance mix and thiuram mix-6 (7.5% each. The ISS differs from the European Standard Series by inclusion of propylene glycol, nitrofurazone, gentamicin, chlorocresol, PEG-400 and ethylenediamine chloride where assesquiterpene lactone mix and primin allergens are excluded.

  20. Standard guide for conducting exfoliation corrosion tests in aluminum alloys

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1992-01-01

    1.1 This guide differs from the usual ASTM standard in that it does not address a specific test. Rather, it is an introductory guide for new users of other standard exfoliation test methods, (see Terminology G 15 for definition of exfoliation). 1.2 This guide covers aspects of specimen preparation, exposure, inspection, and evaluation for conducting exfoliation tests on aluminum alloys in both laboratory accelerated environments and in natural, outdoor atmospheres. The intent is to clarify any gaps in existent test methods. 1.3 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  1. X-ray testing for short-time dynamic applications

    International Nuclear Information System (INIS)

    Kurfiss, Malte; Moser, Stefan; Popko, Gregor; Nau, Siegfried

    2017-01-01

    For nondestructive testing purposes new challenges are short-time dynamic processes. The application of x-ray flash tubes and modern high-speed cameras allows the observation of the opening of air-bags or the energy absorption of compressed tubes as occurring during a vehicle crash. Special algorithms designed for computerized tomography analyses allow the 3D reconstruction at individual time points of the dynamic process. Possibilities and limitations of the actual techniques are discussed.

  2. Stress Optical Coefficient, Test Methodology, and Glass Standard Evaluation

    Science.gov (United States)

    2016-05-01

    ARL-TN-0756 ● MAY 2016 US Army Research Laboratory Stress Optical Coefficient, Test Methodology , and Glass Standard Evaluation...Stress Optical Coefficient, Test Methodology , and Glass Standard Evaluation by Clayton M Weiss Oak Ridge Institute for Science and Education...ORISE), Belcamp, MD Parimal J Patel Weapons and Materials Research Directorate, ARL Approved for public release; distribution is

  3. Standard Operating Procedure for Accelerated Corrosion Testing at ARL

    Science.gov (United States)

    2017-11-01

    ARL-TN-0855 ● NOV 2017 US Army Research Laboratory Standard Operating Procedure for Accelerated Corrosion Testing at ARL by... Corrosion Testing at ARL by Thomas A Considine Weapons and Materials Research Directorate, ARL Approved for public...November 2017 2. REPORT TYPE Technical Note 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE Standard Operating Procedure for Accelerated

  4. Standard Test Method for Oxyacetylene Ablation Testing of Thermal Insulation Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers the screening of ablative materials to determine the relative thermal insulation effectiveness when tested as a flat panel in an environment of a steady flow of hot gas provided by an oxyacetylene burner. 1.2 This test method should be used to measure and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard of materials, products, or assemblies under actual fire conditions. However, results of this test method may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limi...

  5. SHORT- AND LONG-TERM BOND STRENGTHS OF A GOLD STANDARD

    Directory of Open Access Journals (Sweden)

    Safa TUNCER

    2015-04-01

    Full Text Available Purpose: The aim of this study was to investigate the micro tensile bond strength of a self-etch adhesive system following 1 year storage in water. Materials and Methods: 10 sound human molar teeth were used for micro tensile bond strength test. Twostep self-etch dentin adhesive (Clearfil SE Bond® was applied to the flat dentin surfaces according to the manufacturer’s instructions. Composite blocks (Z- 250; 3M ESPE of 5 mm in height have been prepared by using layering technique. Teeth were stored in water for 24 hours at 37°C and longitudinally sectioned to obtain dentin sticks of 1 mm2.Randomly selected samples from half of the teeth were immediately subjected to micro tensile test and. Remaining specimens were tested after 1 year storage in water. Bond strengths were calculated in megapascal (MPa. Results: Means and standard deviations of the Clearfil SE Bond® micro tensile bond strength values were, respectively, 37.31 ± 13.77 MPa and 24.78 ± 2.99 MPa after 24 h and 1 year of storage in water. The difference was statistically significant (p=0.031. Conclusion: Long-term storage in water decreased the micro tensile bond strength values of the twostep self-etch adhesive which has been accepted as the gold standard in bond strength tests.

  6. The Unintentional Memory Load in Tests for Young Children.

    Science.gov (United States)

    Jones, Margaret Hubbard

    The validity of certain standardized tests may be affected by the short-term memory load therein and its relation to a child's short-term memory capacity. Factors of testing which increase a test's memory load and consequently interfere with comprehension are discussed. It is hypothesized that a test which strains the short-term memory capacity of…

  7. The influence of short-term memory on standard discrimination and cued identification olfactory tasks.

    Science.gov (United States)

    Zucco, Gesualdo M; Hummel, Thomas; Tomaiuolo, Francesco; Stevenson, Richard J

    2014-01-30

    Amongst the techniques to assess olfactory functions, discrimination and cued identification are those most prone to the influence of odour short-term memory (STM). Discrimination task requires participants to detect the odd one out of three presented odourants. As re-smelling is not permitted, an un-intended STM load may generate, even though the task purports to assess discrimination ability. Analogously, cued identification task requires participants to smell an odour, and then select a label from three or four alternatives. As the interval between smelling and reading each label increases this too imposes a STM load, even though the task aims to measure identification ability. We tested whether modifying task design to reduce STM load improve performance on these tests. We examined five age-groups of participants (Adolescents, Young adults, Middle-aged, Elderly, very Elderly), some of whom should be more prone to the effects of STM load than others, on standard and modified tests of discrimination and identification. We found that using a technique to reduce STM load improved performance, especially for the very Elderly and Adolescent groups. Sources of error are now prevented. Findings indicate that STM load can adversely affect performance in groups vulnerable from memory impairment (i.e., very Elderly) and in those who may still be acquiring memory-based representations of familiar odours (i.e., Adolescents). It may be that adults in general would be even more sensitive to the effects of olfactory STM load reduction, if the odour-related task was more difficult. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Standard practice for conducting atmospheric corrosion tests on metals

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice covers and defines conditions for exposure of metals and alloys to the weather. It sets forth the general procedures that should be followed in any atmospheric test. It is presented as an aid in conducting atmospheric corrosion tests so that some of the pitfalls of such testing may be avoided. As such, it is concerned mainly with panel exposures to obtain data for comparison purposes. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of whoever uses this standard to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  9. Short Stature

    DEFF Research Database (Denmark)

    Christesen, Henrik Boye Thybo; Pedersen, Birgitte Tønnes; Pournara, Effie

    2016-01-01

    -scale, non-interventional, multinational study. The patient cohort consisted of 5996 short pediatric patients diagnosed with growth hormone deficiency (GHD), Turner syndrome (TS) or born small for gestational age (SGA). The proportions of children with baseline height standard deviation score (SDS) below......The use of appropriate growth standards/references is of significant clinical importance in assessing the height of children with short stature as it may determine eligibility for appropriate therapy. The aim of this study was to determine the impact of using World Health Organization (WHO) instead...... of national growth standards/references on height assessment in short children. Data were collected from routine clinical practice (1998-2014) from nine European countries that have available national growth references and were enrolled in NordiNet® International Outcome Study (IOS) (NCT00960128), a large...

  10. Standard Guide for Conducting Corrosion Tests in Field Applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This guide covers procedures for conducting corrosion tests in plant equipment or systems under operating conditions to evaluate the corrosion resistance of engineering materials. It does not cover electrochemical methods for determining corrosion rates. 1.1.1 While intended primarily for immersion tests, general guidelines provided can be applicable for exposure of test specimens in plant atmospheres, provided that placement and orientation of the test specimens is non-restrictive to air circulation. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See also 10.4.2.

  11. Standardized Definitions for Code Verification Test Problems

    Energy Technology Data Exchange (ETDEWEB)

    Doebling, Scott William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-14

    This document contains standardized definitions for several commonly used code verification test problems. These definitions are intended to contain sufficient information to set up the test problem in a computational physics code. These definitions are intended to be used in conjunction with exact solutions to these problems generated using Exact- Pack, www.github.com/lanl/exactpack.

  12. DOE standard: Filter test facility quality program plan

    International Nuclear Information System (INIS)

    1999-02-01

    This standard was developed primarily for application in US Department of Energy programs. It contains specific direction for HEPA filter testing performed at a DOE-accepted HEPA Filter Test Facility (FTF). Beneficial comments (recommendations, additions, deletions) and any pertinent data that may improve this document should be sent to the Office of Nuclear Safety Policy and Standards (EH-31), US Department of Energy, Washington, DC 20585, by letter or by using the self-addressed Document Improvement Proposal form (DOE F 1300.3) appearing at the end of this document

  13. Precision tests of the Standard Model

    International Nuclear Information System (INIS)

    Ol'shevskij, A.G.

    1996-01-01

    The present status of the precision measurements of electroweak observables is discussed with the special emphasis on the results obtained recently. All together these measurements provide the basis for the stringent test of the Standard Model and determination of the SM parameters. 22 refs., 23 figs., 11 tabs

  14. Fiscal 2000 project for development of international standards for supporting novel industries. Standardization of methods for testing and evaluating pure titanium; 2000 nendo shinki sangyo shiengata kokusai hyojun kaihatsu jigyo. Jun titan no shiken hyoka hoho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    For the purpose of submitting propositions to ISO (International Organization for Standardization)/TC79 (Light metals and their alloys) and ISO/TC135 (Non-destructive testing), studies were made relating to the standardization of methods for chemical ingredient analysis and non-destructive testing of industrial pure titanium. In the development of an ingredient analysis method for pure titanium, performance standards and analytical allowance were determined for an inductively coupled plasma emission spectrochemical analyzer for vanadium, niobium, cobalt, and boron, which were short of completion in the preceding fiscal year. As for spark discharge emission spectrochemical analysis, analysis methods were newly established for oxygen and hydrogen. In the development of optical flaw detection for pure titanium boards, the quality of test pieces were determined by use of a reference test piece, and studies were made about the kinds of artificially produced flaws and a method for sensitivity calibration. In the development of ultrasonic flaw detection for pure titanium boards, studies were made about the effects of board thickness, kinds of flaws, and of board size. Using the findings, a draft standard was prepared in Japanese for a JIS (Japanese Industrial Standards) proposition and another in English for an ISO proposition. (NEDO)

  15. Double standards with radioactive waste

    International Nuclear Information System (INIS)

    Parkinson, A.

    2002-01-01

    The author claims that whether it is short-lived waste from Commonwealth facilities, long-lived plutonium waste from an atomic bomb test site on Aboriginal land, or reactor waste from Lucas Heights, the Australian government applies double standards to suit its own agenda

  16. Standard test method for determination of surface lubrication on flexible webs

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method has been used since 1988 as an ANSI/ISO standard test for determination of lubrication on processed photographic films. Its purpose was to determine the presence of process-surviving lubricants on photographic films. It is the purpose of this test method to expand the applicability of this test method to other flexible webs that may need lubrication for suitable performance. This test measures the breakaway (static) coefficient of friction of a metal rider on the web by the inclined plane method. The objectives of the test is to determine if a web surface has a lubricant present or not. It is not intended to assign a friction coefficient to a material. It is not intended to rank lubricants. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish ...

  17. Standards for Educational and Psychological Testing, 2014 Edition

    Science.gov (United States)

    American Educational Research Association (AERA), 2014

    2014-01-01

    Developed jointly by the American Educational Research Association, American Psychological Association, and the National Council on Measurement in Education, "Standards for Educational and Psychological Testing" (Revised 2014) addresses professional and technical issues of test development and use in education, psychology, and…

  18. SHORT COMMUNICATION: Transportable Zener-diode Voltage Standard

    Science.gov (United States)

    Karpov, O. V.; Shulga, V. M.; Shakirzyanova, F. R.; Sarandi, A. E.

    1994-01-01

    Five transportable Zener-diode dc voltage standards have been developed, fabricated and investigated at the NPO VNIIFTRI. The standards were designed to transfer the unit of electromotive force (emf) from Josephson reference standards to measuring instruments. Following the results of these investigations, standard N 02 has been used for intercomparison of the Russian Josephson reference standards.

  19. USL/DBMS NASA/PC R and D project system testing standards

    Science.gov (United States)

    Dominick, Wayne D. (Editor); Kavi, Srinu; Moreau, Dennis R.; Yan, Lin

    1984-01-01

    A set of system testing standards to be used in the development of all C software within the NASA/PC Research and Development Project is established. Testing will be considered in two phases: the program testing phase and the system testing phase. The objective of these standards is to provide guidelines for the planning and conduct of program and software system testing.

  20. Experimentally testing the standard cosmological model

    Energy Technology Data Exchange (ETDEWEB)

    Schramm, D.N. (Chicago Univ., IL (USA) Fermi National Accelerator Lab., Batavia, IL (USA))

    1990-11-01

    The standard model of cosmology, the big bang, is now being tested and confirmed to remarkable accuracy. Recent high precision measurements relate to the microwave background; and big bang nucleosynthesis. This paper focuses on the latter since that relates more directly to high energy experiments. In particular, the recent LEP (and SLC) results on the number of neutrinos are discussed as a positive laboratory test of the standard cosmology scenario. Discussion is presented on the improved light element observational data as well as the improved neutron lifetime data. alternate nucleosynthesis scenarios of decaying matter or of quark-hadron induced inhomogeneities are discussed. It is shown that when these scenarios are made to fit the observed abundances accurately, the resulting conclusions on the baryonic density relative to the critical density, {Omega}{sub b}, remain approximately the same as in the standard homogeneous case, thus, adding to the robustness of the standard model conclusion that {Omega}{sub b} {approximately} 0.06. This latter point is the deriving force behind the need for non-baryonic dark matter (assuming {Omega}{sub total} = 1) and the need for dark baryonic matter, since {Omega}{sub visible} < {Omega}{sub b}. Recent accelerator constraints on non-baryonic matter are discussed, showing that any massive cold dark matter candidate must now have a mass M{sub x} {approx gt} 20 GeV and an interaction weaker than the Z{sup 0} coupling to a neutrino. It is also noted that recent hints regarding the solar neutrino experiments coupled with the see-saw model for {nu}-masses may imply that the {nu}{sub {tau}} is a good hot dark matter candidate. 73 refs., 5 figs.

  1. Experimentally testing the standard cosmological model

    International Nuclear Information System (INIS)

    Schramm, D.N.

    1990-11-01

    The standard model of cosmology, the big bang, is now being tested and confirmed to remarkable accuracy. Recent high precision measurements relate to the microwave background; and big bang nucleosynthesis. This paper focuses on the latter since that relates more directly to high energy experiments. In particular, the recent LEP (and SLC) results on the number of neutrinos are discussed as a positive laboratory test of the standard cosmology scenario. Discussion is presented on the improved light element observational data as well as the improved neutron lifetime data. alternate nucleosynthesis scenarios of decaying matter or of quark-hadron induced inhomogeneities are discussed. It is shown that when these scenarios are made to fit the observed abundances accurately, the resulting conclusions on the baryonic density relative to the critical density, Ω b , remain approximately the same as in the standard homogeneous case, thus, adding to the robustness of the standard model conclusion that Ω b ∼ 0.06. This latter point is the deriving force behind the need for non-baryonic dark matter (assuming Ω total = 1) and the need for dark baryonic matter, since Ω visible b . Recent accelerator constraints on non-baryonic matter are discussed, showing that any massive cold dark matter candidate must now have a mass M x approx-gt 20 GeV and an interaction weaker than the Z 0 coupling to a neutrino. It is also noted that recent hints regarding the solar neutrino experiments coupled with the see-saw model for ν-masses may imply that the ν τ is a good hot dark matter candidate. 73 refs., 5 figs

  2. Comparison of Size Modulation Standard Automated Perimetry and Conventional Standard Automated Perimetry with a 10-2 Test Program in Glaucoma Patients.

    Science.gov (United States)

    Hirasawa, Kazunori; Takahashi, Natsumi; Satou, Tsukasa; Kasahara, Masayuki; Matsumura, Kazuhiro; Shoji, Nobuyuki

    2017-08-01

    This prospective observational study compared the performance of size modulation standard automated perimetry with the Octopus 600 10-2 test program, with stimulus size modulation during testing, based on stimulus intensity and conventional standard automated perimetry, with that of the Humphrey 10-2 test program in glaucoma patients. Eighty-seven eyes of 87 glaucoma patients underwent size modulation standard automated perimetry with Dynamic strategy and conventional standard automated perimetry using the SITA standard strategy. The main outcome measures were global indices, point-wise threshold, visual defect size and depth, reliability indices, and test duration; these were compared between size modulation standard automated perimetry and conventional standard automated perimetry. Global indices and point-wise threshold values between size modulation standard automated perimetry and conventional standard automated perimetry were moderately to strongly correlated (p 33.40, p modulation standard automated perimetry than with conventional standard automated perimetry, but the visual-field defect size was smaller (p modulation-standard automated perimetry than on conventional standard automated perimetry. The reliability indices, particularly the false-negative response, of size modulation standard automated perimetry were worse than those of conventional standard automated perimetry (p modulation standard automated perimetry than with conventional standard automated perimetry (p = 0.02). Global indices and the point-wise threshold value of the two testing modalities correlated well. However, the potential of a large stimulus presented at an area with a decreased sensitivity with size modulation standard automated perimetry could underestimate the actual threshold in the 10-2 test protocol, as compared with conventional standard automated perimetry.

  3. Critical Review of Commercial Secondary Lithium-Ion Battery Safety Standards

    Science.gov (United States)

    Jones, Harry P.; Chapin, Thomas, J.; Tabaddor, Mahmod

    2010-09-01

    The development of Li-ion cells with greater energy density has lead to safety concerns that must be carefully assessed as Li-ion cells power a wide range of products from consumer electronics to electric vehicles to space applications. Documented field failures and product recalls for Li-ion cells, mostly for consumer electronic products, highlight the risk of fire, smoke, and even explosion. These failures have been attributed to the occurrence of internal short circuits and the subsequent thermal runaway that can lead to fire and explosion. As packaging for some applications include a large number of cells, the risk of failure is likely to be magnified. To address concerns about the safety of battery powered products, safety standards have been developed. This paper provides a review of various international safety standards specific to lithium-ion cells. This paper shows that though the standards are harmonized on a host of abuse conditions, most lack a test simulating internal short circuits. This paper describes some efforts to introduce internal short circuit tests into safety standards.

  4. Annual meeting 1996 'Nondestructive materials testing'. German, Austrian and Swiss nondestructive materials testing standards as mirrored by international standardization. Vol. 1. Lectures

    International Nuclear Information System (INIS)

    1996-01-01

    The volume contains 45 lectures which were given at the annual meeting of the German Society for Nondestructive Testing on May 13-15, 1996 at Lindau. The main subjects were: Standardization of nondestructive testing, irradiation testing, ultrasonic testing and electromagnetic processes. 13 individual articles were included in the ENERGY database. (MM) [de

  5. Annual meeting 1996 'Nondestructive material testing'. German, Austrian and Swiss nondestructive materials testing standards as mirrored by international standardization. Vol. 2. Posters

    International Nuclear Information System (INIS)

    1996-01-01

    The volume contains 49 poster articles which were presented at the Annual Meeting of the German Society for Nondestructive Testing at Lindau on May 13-15, 1996. The main subjects were: Standardization of nondestructive testing, irradiation testing, ultrasonic testing and electromagnetic processes. 16 individual articles were included in the ENERGY databank. (MM) [de

  6. A short-form version of the Boston Naming Test for language screening in dementia in a bilingual rural community in Galicia (Spain).

    Science.gov (United States)

    Nebreda, M C; García-Caballero, A; Asensio, E; Revilla, P; Rodriguez-Girondo, M; Mateos, R

    2011-04-01

    Aphasia, one of the core symptoms of cortical dementia, is routinely evaluated using graded naming tests like the Boston Naming Test (BNT). However, the application of this 60-item test is time-consuming and shortened versions have been devised for screening. The hypothesis of this research is that a specifically designed shortened version of the BNT could replace the original 60-item BNT as part of a mini-battery for screening for dementia. The objective of this study was to design a short version of the BNT for a rural population in Galicia (Spain). A clinic group of 102 patients including 43 with dementia was recruited along with 78 healthy volunteers. The clinic and control groups were scored on the Spanish version of the Mini-mental State Examination (MMSE) and BNT. In addition, the clinic group was tested with standard neuropsychological instruments and underwent brain investigations and routine neurological examination. BNT items with specificity and sensitivity above 0.5 were selected to compose a short battery of 11 pictures named BNTOu11. ANOVA and mean comparisons were made for MMSE and BNT versions. Receiver operating characteristics (ROC) curves and internal consistency were calculated. Areas under ROC curves (AUC) did not show statistically significant differences; therefore BNTOu11's AUC (0.814) was similar to the 60-item BNT versions (0.785 and 0.779), to the short versions from Argentina (0.772) and Andalusia (0.799) and to the Spanish MMSE (0.866). BNTOu11 had higher internal consistency than the other short versions. BNTOu11 is a useful and time-saving method as part of a battery for screening for dementia in a psychogeriatric outpatient unit.

  7. Standard test method for measuring pH of soil for use in corrosion testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1995-01-01

    1.1 This test method covers a procedure for determining the pH of a soil in corrosion testing. The principle use of the test is to supplement soil resistivity measurements and thereby identify conditions under which the corrosion of metals in soil may be accentuated (see G 57 - 78 (1984)). 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  8. 46 CFR 54.10-10 - Standard hydrostatic test (modifies UG-99).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Standard hydrostatic test (modifies UG-99). 54.10-10... PRESSURE VESSELS Inspection, Reports, and Stamping § 54.10-10 Standard hydrostatic test (modifies UG-99). (a) All pressure vessels shall satisfactorily pass the hydrostatic test prescribed by this section...

  9. Nondestructive testing standards and the ASME code

    International Nuclear Information System (INIS)

    Spanner, J.C.

    1991-04-01

    Nondestructive testing (NDT) requirements and standards are an important part of the ASME Boiler and Pressure Vessel Code. In this paper, the evolution of these requirements and standards is reviewed in the context of the unique technical and legal stature of the ASME Code. The coherent and consistent manner by which the ASME Code rules are organized is described, and the interrelationship between the various ASME Code sections, the piping codes, and the ASTM Standards is discussed. Significant changes occurred in ASME Sections 5 and 11 during the 1980s, and these are highlighted along with projections and comments regarding future trends and changes in these important documents. 4 refs., 8 tabs

  10. Standard practice for conducting and evaluating laboratory corrosions tests in soils

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This practice covers procedures for conducting laboratory corrosion tests in soils to evaluate the corrosive attack on engineering materials. 1.2 This practice covers specimen selection and preparation, test environments, and evaluation of test results. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. Standard practice for conducting moist SO2 tests

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This practice covers the apparatus and procedure to be used in conducting qualitative assessment tests in accordance with the requirements of material or product specifications by means of specimen exposure to condensed moisture containing sulfur dioxide. 1.2 The exposure conditions may be varied to suit particular requirements and this practice includes provisions for use of different concentrations of sulfur dioxide and for tests either running continuously or in cycles of alternate exposure to the sulfur dioxide containing atmosphere and to the ambient atmosphere. 1.3 The variant of the test to be used, the exposure period required, the type of test specimen, and the criteria of failure are not prescribed by this practice. Such details are provided in appropriate material and product purchase specifications. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety c...

  12. Balancing standardized testing with personalized training in surgery

    Directory of Open Access Journals (Sweden)

    Ahmed A

    2016-12-01

    Full Text Available Aadil Ahmed, Muhammad Abbas Abid, Nasir I Bhatti Department of Otolaryngology-Head and Neck Surgery, The Johns Hopkins School of Medicine, Baltimore, MD, USA Abstract: Students pursuing a medical career in the US are subject to standardized testing at regular intervals. These standardized tests not only quantify the milestones students have already achieved, but also define the path for future achievements. The purpose of these examinations is to help students become self-directed, lifelong learners – an essential attribute of a medical professional. However, whether preparing for these examinations actually makes students such disciplined learners needs to be examined. Especially during residency training with its limited time and unpredictable exposure, trainees must learn in the most efficient way for their learning styles, and thus develop attributes that will be helpful to them in their medical career. In this review, we propose that a personalized, learner-centered approach tailored to residents’ educational needs and preferences can not only fulfill learning interests and objectives but also serve as a time-efficient and cost-effective approach for graduate medical education. Keywords: standardized testing, personalized training, surgery

  13. Does priming with sex steroids improve the diagnosis of normal growth hormone secretion in short children?

    Directory of Open Access Journals (Sweden)

    Ashraf Soliman

    2014-01-01

    Full Text Available Introduction: There is still controversy for priming with sex steroid before growth hormone (GH testing. Objective: We studied GH response to stimulation in 92 children >9 years with idiopathic short stature (height standard deviation score [HtSDS]-2. They were divided randomly into two groups. Children in Group 1 (n = 50 were primed with premarin in girls and testosterone in boys and those in Group 2 were not primed (n = 42. All children were tested using standard clonidine test and their serum insulin-like growth factor-I concentration (IGF-I. Additionally the growth and GH-IGF-I data of the two groups of children were compared with those for 32 short children (HtSDS 9 years. The peak GH response to clonidine provocation test did not differ before (n = 42 versus after 9 years (n = 32 of age. Conclusions: In this randomized study priming with sex steroids before GH testing did not significantly increase the yield of diagnosing short patients with normal GH secretion. In addition, GH response to provocation did not vary significantly between young (9 years short children.

  14. Does standard deviation matter? Using "standard deviation" to quantify security of multistage testing.

    Science.gov (United States)

    Wang, Chun; Zheng, Yi; Chang, Hua-Hua

    2014-01-01

    With the advent of web-based technology, online testing is becoming a mainstream mode in large-scale educational assessments. Most online tests are administered continuously in a testing window, which may post test security problems because examinees who take the test earlier may share information with those who take the test later. Researchers have proposed various statistical indices to assess the test security, and one most often used index is the average test-overlap rate, which was further generalized to the item pooling index (Chang & Zhang, 2002, 2003). These indices, however, are all defined as the means (that is, the expected proportion of common items among examinees) and they were originally proposed for computerized adaptive testing (CAT). Recently, multistage testing (MST) has become a popular alternative to CAT. The unique features of MST make it important to report not only the mean, but also the standard deviation (SD) of test overlap rate, as we advocate in this paper. The standard deviation of test overlap rate adds important information to the test security profile, because for the same mean, a large SD reflects that certain groups of examinees share more common items than other groups. In this study, we analytically derived the lower bounds of the SD under MST, with the results under CAT as a benchmark. It is shown that when the mean overlap rate is the same between MST and CAT, the SD of test overlap tends to be larger in MST. A simulation study was conducted to provide empirical evidence. We also compared the security of MST under the single-pool versus the multiple-pool designs; both analytical and simulation studies show that the non-overlapping multiple-pool design will slightly increase the security risk.

  15. Agreement between gastrointestinal panel testing and standard microbiology methods for detecting pathogens in suspected infectious gastroenteritis: Test evaluation and meta-analysis in the absence of a reference standard.

    Science.gov (United States)

    Freeman, Karoline; Tsertsvadze, Alexander; Taylor-Phillips, Sian; McCarthy, Noel; Mistry, Hema; Manuel, Rohini; Mason, James

    2017-01-01

    Multiplex gastrointestinal pathogen panel (GPP) tests simultaneously identify bacterial, viral and parasitic pathogens from the stool samples of patients with suspected infectious gastroenteritis presenting in hospital or the community. We undertook a systematic review to compare the accuracy of GPP tests with standard microbiology techniques. Searches in Medline, Embase, Web of Science and the Cochrane library were undertaken from inception to January 2016. Eligible studies compared GPP tests with standard microbiology techniques in patients with suspected gastroenteritis. Quality assessment of included studies used tailored QUADAS-2. In the absence of a reference standard we analysed test performance taking GPP tests and standard microbiology techniques in turn as the benchmark test, using random effects meta-analysis of proportions. No study provided an adequate reference standard with which to compare the test accuracy of GPP and conventional tests. Ten studies informed a meta-analysis of positive and negative agreement. Positive agreement across all pathogens was 0.93 (95% CI 0.90 to 0.96) when conventional methods were the benchmark and 0.68 (95% CI: 0.58 to 0.77) when GPP provided the benchmark. Negative agreement was high in both instances due to the high proportion of negative cases. GPP testing produced a greater number of pathogen-positive findings than conventional testing. It is unclear whether these additional 'positives' are clinically important. GPP testing has the potential to simplify testing and accelerate reporting when compared to conventional microbiology methods. However the impact of GPP testing upon the management, treatment and outcome of patients is poorly understood and further studies are needed to evaluate the health economic impact of GPP testing compared with standard methods. The review protocol is registered with PROSPERO as CRD42016033320.

  16. Private Pilot Practical Test Standards for Airplane (SEL, MEL, SES, MES)

    Science.gov (United States)

    1995-05-01

    The Private Pilot - Airplane Practical Test Standards book has been : published by the Federal Aviation Administration (FAA) to establish the : standards for the private pilot certification practical tests for the airplane : category and the single-e...

  17. Device for testing continuity and/or short circuits in a cable

    Science.gov (United States)

    Hayhurst, Arthur R. (Inventor)

    1995-01-01

    A device for testing current paths is attachable to a conductor. The device automatically checks the current paths of the conductor for continuity of a center conductor, continuity of a shield and a short circuit between the shield and the center conductor. The device includes a pair of connectors and a circuit to provide for testing of the conductive paths of the cable. The pair of connectors electrically connects the conductive paths of a cable to be tested with the circuit paths of the circuit. The circuit paths in the circuit include indicators to simultaneously indicate the results of the testing.

  18. Detecting dementia in patients with normal neuropsychological screening by Short Smell Test and Palmo-Mental Reflex Test: an observational study.

    Science.gov (United States)

    Streit, Sven; Limacher, Andreas; Zeller, Andreas; Bürge, Markus

    2015-07-25

    General practitioners (GPs) are in best position to suspect dementia. Mini-Mental State Examination (MMSE) and Clock Drawing Test (CDT) are widely used. Additional neurological tests may increase the accuracy of diagnosis. We aimed to evaluate diagnostic ability to detect dementia with a Short Smell Test (SST) and Palmo-Mental Reflex (PMR) in patients whose MMSE and CDT are normal, but who show signs of cognitive dysfunction. This was a 3.5-year cross-sectional observational study in the Memory Clinic of the University Department of Geriatrics in Bern, Switzerland. Participating patients with normal MMSE (>26 points) and CDT (>5 points) were referred by GPs because they suspected dementia. All were examined according to a standardized protocol. Diagnosis of dementia was based on DSM-IV TR criteria. We used SST and PMR to determine if they accurately detected dementia. In our cohort, 154 patients suspected of dementia had normal MMSE and CDT test results. Of these, 17 (11%) were demented. If SST or PMR were abnormal, sensitivity was 71% (95% CI 44-90%), and specificity 64% (95% CI 55-72%) for detecting dementia. If both tests were abnormal, sensitivity was 24% (95% CI 7-50%), but specificity increased to 93% (95% CI 88-97%). Patients suspected of dementia, but with normal MMSE and CDT results, may benefit if SST and PMR are added as diagnostic tools. If both SST and PMR are abnormal, this is a red flag to investigate these patients further, even though their negative neuropsychological screening results.

  19. Effects of an Inquiry-Based Short Intervention on State Test Anxiety in Comparison to Alternative Coping Strategies

    Directory of Open Access Journals (Sweden)

    Ann Krispenz

    2018-02-01

    Full Text Available Background and Objectives: Test anxiety can have undesirable consequences for learning and academic achievement. The control-value theory of achievement emotions assumes that test anxiety is experienced if a student appraises an achievement situation as important (value appraisal, but feels that the situation and its outcome are not fully under his or her control (control appraisal. Accordingly, modification of cognitive appraisals is assumed to reduce test anxiety. One method aiming at the modification of appraisals is inquiry-based stress reduction. In the present study (N = 162, we assessed the effects of an inquiry-based short intervention on test anxiety.Design: Short-term longitudinal, randomized control trial.Methods: Focusing on an individual worry thought, 53 university students received an inquiry-based short intervention. Control participants reflected on their worry thought (n = 55 or were distracted (n = 52. Thought related test anxiety was assessed before, immediately after, and 2 days after the experimental treatment.Results: After the intervention as well as 2 days later, individuals who had received the inquiry-based intervention demonstrated significantly lower test anxiety than participants from the pooled control groups. Further analyses showed that the inquiry-based short intervention was more effective than reflecting on a worry thought but had no advantage over distraction.Conclusions: Our findings provide first experimental evidence for the effectiveness of an inquiry-based short intervention in reducing students’ test anxiety.

  20. A proposed standard round compact specimen for plane strain fracture toughness testing

    Science.gov (United States)

    Underwood, J. H.; Newman, J. C., Jr.; Seeley, R. R.

    1980-01-01

    A round, disk-shaped specimen is proposed as a standard test specimen for addition to ASTM Test for Plane-Strain Fracture Toughness of Metallic Materials (E 399-78A). The specimen is diametrically cracked, and loaded in the same way as the existing standard compact specimen. Tests and analyses were performed to verify that the proposed round compact specimen and associated stress intensity factor K solution are appropriate for a standard plane strain fracture toughness test. The use of the round compact specimen for other fracture tests is described.

  1. Result of standard patch test in patients suspected of having allergic contact dermatitis.

    Science.gov (United States)

    Wongpiyabovorn, Jongkonnee; Puvabanditsin, Porntip

    2005-09-01

    Contact dermatitis is a common skin disease. Disease was diagnosed by a history of contact substance together with geographic distribution of lesion. Up till now, standard patch test is one of the most reliable test to identify and confirm causative agent of allergic contact dermatitis. To determine the rate of positive standard patch test and to identify the common allergen of contact dermatitis in Thailand, we performed the standard patch test in 129 patients, suspected having allergic contact dermatitis at Department of Dermatology, King Chulalongkorn Memorial Hospital, Thailand from June 1, 2003 to September 1, 2004. The rate of positive standard patch test is 59.7% (n = 77/129). The most 3 common positive allergens were nickel sulfate (18.60%), cobalt chloride (17.05%) and fragrance mix (14.73%), respectively. The chance of positive standard patch test significantly correlated with sex (woman), initial diagnosis as contact dermatitis and history of house-worker (p = 0.017, p = 0.005 and p = 0.023, respectively). Whereas, there were no significant correlation between the chance of positive standard patch test and age of patient, location of lesion, history of recurrence, history of atopy, history of drug and food allergy. In addition, history of metal allergy significantly correlated with the chance of positive nickel sulfate or cobalt chloride in standard patch test (p = 0.017). In conclusion, this study demonstrated the prevalence of causative allergen of contact dermatitis in Thai patients using that standard patch test. Moreover, our data shown that the chance positive standard patch test was greater in patient, who were women or initial diagnosed as contact dermatitis or had history of houseworker or history of metal allergy.

  2. Development of standard testing methods for nuclear-waste forms

    International Nuclear Information System (INIS)

    Mendel, J.E.; Nelson, R.D.

    1981-11-01

    Standard test methods for waste package component development and design, safety analyses, and licensing are being developed for the Nuclear Waste Materials Handbook. This paper describes mainly the testing methods for obtaining waste form materials data

  3. Standard test method for liquid impingement erosion using rotating apparatus

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers tests in which solid specimens are eroded or otherwise damaged by repeated discrete impacts of liquid drops or jets. Among the collateral forms of damage considered are degradation of optical properties of window materials, and penetration, separation, or destruction of coatings. The objective of the tests may be to determine the resistance to erosion or other damage of the materials or coatings under test, or to investigate the damage mechanisms and the effect of test variables. Because of the specialized nature of these tests and the desire in many cases to simulate to some degree the expected service environment, the specification of a standard apparatus is not deemed practicable. This test method gives guidance in setting up a test, and specifies test and analysis procedures and reporting requirements that can be followed even with quite widely differing materials, test facilities, and test conditions. It also provides a standardized scale of erosion resistance numbers applicab...

  4. Standard practice for instrumented indentation testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This practice defines the basic steps of Instrumented Indentation Testing (IIT) and establishes the requirements, accuracies, and capabilities needed by an instrument to successfully perform the test and produce the data that can be used for the determination of indentation hardness and other material characteristics. IIT is a mechanical test that measures the response of a material to the imposed stress and strain of a shaped indenter by forcing the indenter into a material and monitoring the force on, and displacement of, the indenter as a function of time during the full loading-unloading test cycle. 1.2 The operational features of an IIT instrument, as well as requirements for Instrument Verification Annex A1), Standardized Reference Blocks (Annex A2) and Indenter Requirements (Annex A3) are defined. This practice is not intended to be a complete purchase specification for an IIT instrument. 1.3 With the exception of the non-mandatory Appendix X4, this practice does not define the analysis necessary...

  5. Assessing cultural validity in standardized tests in stem education

    Science.gov (United States)

    Gassant, Lunes

    This quantitative ex post facto study examined how race and gender, as elements of culture, influence the development of common misconceptions among STEM students. Primary data came from a standardized test: the Digital Logic Concept Inventory (DLCI) developed by Drs. Geoffrey L. Herman, Michael C. Louis, and Craig Zilles from the University of Illinois at Urbana-Champaign. The sample consisted of a cohort of 82 STEM students recruited from three universities in Northern Louisiana. Microsoft Excel and the Statistical Package for the Social Sciences (SPSS) were used for data computation. Two key concepts, several sub concepts, and 19 misconceptions were tested through 11 items in the DLCI. Statistical analyses based on both the Classical Test Theory (Spearman, 1904) and the Item Response Theory (Lord, 1952) yielded similar results: some misconceptions in the DLCI can reliably be predicted by the Race or the Gender of the test taker. The research is significant because it has shown that some misconceptions in a STEM discipline attracted students with similar ethnic backgrounds differently; thus, leading to the existence of some cultural bias in the standardized test. Therefore the study encourages further research in cultural validity in standardized tests. With culturally valid tests, it will be possible to increase the effectiveness of targeted teaching and learning strategies for STEM students from diverse ethnic backgrounds. To some extent, this dissertation has contributed to understanding, better, the gap between high enrollment rates and low graduation rates among African American students and also among other minority students in STEM disciplines.

  6. Standard guide for conducting and evaluating galvanic corrosion tests in electrolytes

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1981-01-01

    1.1 This guide covers conducting and evaluating galvanic corrosion tests to characterize the behavior of two dissimilar metals in electrical contact in an electrolyte under low-flow conditions. It can be adapted to wrought or cast metals and alloys. 1.2 This guide covers the selection of materials, specimen preparation, test environment, method of exposure, and method for evaluating the results to characterize the behavior of galvanic couples in an electrolyte. Note 1—Additional information on galvanic corrosion testing and examples of the conduct and evaluation of galvanic corrosion tests in electrolytes are given in Refs (1) through (7). 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicabil...

  7. IEEE C37.98-1987: IEEE standard seismic testing of relays

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This standard specifies the procedures to be used in the seismic testing of relays used in power system facilities. The standard is concerned with the determination of the seismic fragility level of relays and also gives recommendations for proof testing. The purpose of this standard is to establish procedures for determining the seismic capabilities of protective and auxiliary relays. These procedures employ what has been called fragility testing in IEEE Std 344-1987. To define the conditions for fragility testing of relays, parameters in three separate areas must be specified. In general, they are (1) the electrical settings and inputs to the relay, and other information to define its conditions during the test; (2) the change in state, deviation in operating characteristics or tolerances, or other change of performance of the relay that constitutes failure; (3) the seismic vibration environment to be imposed during the test. Since it is not possible to define the conditions for every conceivable application for all relays, those parameters, which in practice encompass the majority of applications, have been specified in this standard. When the application of the relay is other than as specified under any of (1), (2), and (3), or if it is not practical to apply existing results of fragility tests to that new application, then proof testing must be performed for that new case

  8. The Weighted Airman Promotion System: Standardizing Test Scores

    Science.gov (United States)

    2008-01-01

    u th o ri ze d Top 3/E6 ratio, inventory 1401206040 100 70 130 5R 2F 2G 3N 2M 2A 4J 4C 4P 4T 4B 1W 2T 3P 1T 4A 2S 5J 1A 1S1C 6F 4N 7S 4R 4E 1N 3A 3V...System: Standardizing Test Scores AFHRL convened a panel to identify the relevant factors to consider, and then sit as a promotion board and rank...Costs If the Air Force decided to standardize test scores, there would be three basic types of costs: implementation costs, marketing costs, and

  9. Development of a Short Form of the Boston Naming Test for Individuals with Aphasia

    Science.gov (United States)

    del Toro, Christina M.; Bislick, Lauren P.; Comer, Matthew; Velozo, Craig; Romero, Sergio; Rothi, Leslie J. Gonzalez; Kendall, Diane L.

    2011-01-01

    Purpose: The purpose of this study was to develop a short form of the Boston Naming Test (BNT; Kaplan, Goodglass, & Weintraub, 2001) for individuals with aphasia and compare it with 2 existing short forms originally analyzed with responses from people with dementia and neurologically healthy adults. Method: Development of the new BNT-Aphasia Short…

  10. Standardization of Tests for Advanced Composites

    OpenAIRE

    石川, 隆司; ISHIKAWA, Takashi; 野口, 義男; NOGUCHI, Yoshio; 濱口, 泰正; HAMAGUCHI, Yasumasa

    2003-01-01

    Advanced composites are essentially the only feasible materials for the construction of newly developed aerospace vehicle. However, the path to be followed for the validation, evaluation and certification of composite aircraft structures is quite different from that of traditional metallic aircraft structures, and the importance of a composites database is now well recognized. A key issue in constructing a fully descriptive composites database is to establish standard composite test methods, ...

  11. Standardization of penetrating radiation testing system

    International Nuclear Information System (INIS)

    Wiley, P.A.; Aronson, H.L.

    1979-01-01

    Standardization is provided to control system gain of a penetrating radiation testing system by periodically inspecting a reference object in the same manner as the product samples so as to generate a stabilization signal which is compared to a reference signal. The difference, if any, between the stabilization signal and the reference signal is integrated and the integrated signal is used to correct the gain of the system

  12. Microstructure and elemental distribution of americium containing MOX fuel under the short term irradiation tests

    International Nuclear Information System (INIS)

    Tanaka, Kosuke; Hirosawa, Takashi; Obayashi, Hiroshi; Koyama, Shin Ichi; Yoshimochi, Hiroshi; Tanaka, Kenya

    2008-01-01

    In order to investigate the effect of americium addition to MOX fuels on the irradiation behavior, the 'Am-1' program is being conducted in JAEA. The Am-1 program consists of two short term irradiation tests of 10-minute and 24 hour irradiations and a steady-state irradiation test. The short-term irradiation tests were successfully completed and the post irradiation examinations (PIEs) are in progress. The PIEs for Am-containing MOX fuels focused on the microstructural evolution and redistribution behavior of Am at the initial stage of irradiation and the results to date are reported

  13. Political Judgement, Freedom of Thought, and Standardized Testing: A Critical Enquiry

    Science.gov (United States)

    Schuler, Matthew Edward

    2012-01-01

    The practice of "standardized" testing has been embedded in United States federal education policy since at least the passage of the Elementary and Secondary Education Act of 1965. The roots of standardized testing in American education, grounded in Kantian "Modern Thought," can be traced to the U.S. Military Academy at…

  14. Safe and secure South Africa. Vehicle landmine protection validation testing

    CSIR Research Space (South Africa)

    Reinecke, JD

    2008-11-01

    Full Text Available The objective of this paper is to provide an overview of vehicle landmine protection validation testing in South Africa. A short history of validation test standards is given, followed by a summary of current open test standards in general use...

  15. Within-day variability on short and long walking tests in persons with multiple sclerosis

    NARCIS (Netherlands)

    Feys, P.; Bibby, B.; Romberg, A.; Santoyo, C.; Gebara, B.; de Noordhout, B.M.; Knuts, K.; Bethoux, F.; Skjerbaek, A.; Jensen, E.; Baert, I.; Vaney, C.; de Groot, V.; Dalgas, U.

    2014-01-01

    Objective To compare within-day variability of short (10 m walking test at usual and fastest speed; 10MWT) and long (2 and 6-minute walking test; 2MWT/6MWT) tests in persons with multiple sclerosis. Design Observational study. Setting MS rehabilitation and research centers in Europe and US within

  16. IEEE C37.98-1978: IEEE standard seismic testing of relays

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This standard specifies the procedures to be used in the seismic testing of relays used in power system facilities. The standard is concerned with the determination of the seismic fragility level of relays and also gives recommendations for proof testing. The purpose of this standard is to establish procedures for determining the seismic capabilities of protective and auxiliary relays. These procedures employ what has been called fragility testing in ANSI/IEEE Std 344-1975, Recommended Practices for Seismic Qualification of Class 1E Equipment for Nuclear Power Generating Stations. In order to define the conditions for fragility testing of relays, parameters in three separate areas must be specified. In general they are: (1) the electrical settings and inputs to the relay, and other information to define its conditions during the test; (2) the change in state, deviation in operating characteristics or tolerances, or other change of performance of the relay which constitutes failure; (3) the seismic vibration environment to be imposed during the test. Since it is not possible to define the conditions for every conceivable application for all relays, those parameters, which in practice encompass the majority of applications, have been specified in this standard. When the application of the relay is other than as specified under any of (1), (2), and (3), or if it is not practical to apply existing results of fragility tests to that new case

  17. Performance testing of HEPA filters: Progress towards a European standard procedure

    Energy Technology Data Exchange (ETDEWEB)

    Dyment, J.

    1997-08-01

    Proposals for a future European testing procedure for {open_quotes}High Efficiency Particulate Air Filters (HEPA and ULPA){close_quotes} are being developed by CEN (Comite Europeen de Normalisation). The new standard will be given the status of national standard in participating countries, conflicting national standards being withdrawn. The standard will comprise 5 parts covering the grouping and classification of HEPA and ULPA filters according to their efficiency, fundamental principles of testing, marking etc (in part 1). Part 2 will cover aerosol production, measurement principles, counting equipment and statistics. Parts 3-5 will cover testing flat sheet media, leak testing of filter elements and the efficiency testing of filter elements respectively. The efficiency test methods allow the use of either homogeneous monodisperse or polydisperse aerosols for the determination of particulate filtration efficiencies as a function of particle size. The particle size at which maximum penetration occurs is first determined in flat sheet media tests; tests on filter elements (constructed using the same filter medium) may be carried out using either a homogeneous monodisperse aerosol of the size at which maximum penetration occurs (MPPS) or a polydisperse aerosol whose median size is close to the MPPS. Tests with monodisperse aerosols may be conducted using condensation nucleus counting equipment; tests using polydisperse test aerosols require the use of optical sizing particle counters. When determining the efficiency of filter elements the downstream aerosol concentrations may be determined from air samples obtained using either an overall method (single point sampling after mixing) or a scan method. The scan method also allows {open_quotes}local{close_quotes} efficiency values to be determined. 1 ref., 1 fig., 1 tab.

  18. Standard Specification for Steel Blades Used with the Photovoltaic Module Surface Cut Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This specification specifies the recommended physical characteristics of the steel blades required for the surface cut test described in ANSI/UL 1703 (Section 24) and IEC 61730-2 (Paragraph 10.3). 1.2 ANSI/UL 1703 and IEC 61730-2 are standards for photovoltaic module safety testing. 1.3 This standard provides additional fabrication details for the surface cut test blades that are not provided in ANSI/UL 1703 or IEC 61730-2. Surface cut test blades that have out-of-tolerance corner radii or burrs are known to cause erroneous test results, either passes or failures. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. Standard operation procedures for conducting the on-the-road driving test, and measurement of the standard deviation of lateral position (SDLP).

    Science.gov (United States)

    Verster, Joris C; Roth, Thomas

    2011-01-01

    This review discusses the methodology of the standardized on-the-road driving test and standard operation procedures to conduct the test and analyze the data. The on-the-road driving test has proven to be a sensitive and reliable method to examine driving ability after administration of central nervous system (CNS) drugs. The test is performed on a public highway in normal traffic. Subjects are instructed to drive with a steady lateral position and constant speed. Its primary parameter, the standard deviation of lateral position (SDLP), ie, an index of 'weaving', is a stable measure of driving performance with high test-retest reliability. SDLP differences from placebo are dose-dependent, and do not depend on the subject's baseline driving skills (placebo SDLP). It is important that standard operation procedures are applied to conduct the test and analyze the data in order to allow comparisons between studies from different sites.

  20. Standard test method for measurement of web/roller friction characteristics

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This test method covers the simulation of a roller/web transport tribosystem and the measurement of the static and kinetic coefficient of friction of the web/roller couple when sliding occurs between the two. The objective of this test method is to provide users with web/roller friction information that can be used for process control, design calculations, and for any other function where web/roller friction needs to be known. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  1. Standard Test Method for Abrasive Wear Resistance of Cemented

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the determination of abrasive wear resistance of cemented carbides. 1.2 The values stated in inch-pound units are to be regarded as the standard. The SI equivalents of inch-pound units are in parentheses and may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. Short-term standard litter decomposition across three different ecosystems in middle taiga zone of West Siberia

    Science.gov (United States)

    Filippova, Nina V.; Glagolev, Mikhail V.

    2018-03-01

    The method of standard litter (tea) decomposition was implemented to compare decomposition rate constants (k) between different peatland ecosystems and coniferous forests in the middle taiga zone of West Siberia (near Khanty-Mansiysk). The standard protocol of TeaComposition initiative was used to make the data usable for comparisons among different sites and zonobiomes worldwide. This article sums up the results of short-term decomposition (3 months) on the local scale. The values of decomposition rate constants differed significantly between three ecosystem types: it was higher in forest compared to bogs, and treed bogs had lower decomposition constant compared to Sphagnum lawns. In general, the decomposition rate constants were close to ones reported earlier for similar climatic conditions and habitats.

  3. 42 CFR 493.1252 - Standard: Test systems, equipment, instruments, reagents, materials, and supplies.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Test systems, equipment, instruments... SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY... storage of reagents and specimens, accurate and reliable test system operation, and test result reporting...

  4. 78 FR 17875 - Commercial Driver's License Testing and Commercial Learner's Permit Standards

    Science.gov (United States)

    2013-03-25

    ... [Docket No. FMCSA-2007-27659] RIN 2126-AB59 Commercial Driver's License Testing and Commercial Learner's.... The 2011 final rule amended the commercial driver's license (CDL) knowledge and skills testing standards and established new minimum Federal standards for States to issue the commercial learner's permit...

  5. Amsterdam Short-Term Memory test: a new procedure for the detection of feigned memory deficits

    NARCIS (Netherlands)

    Schagen, S.; Schmand, B.; de Sterke, S.; Lindeboom, J.

    1997-01-01

    The validity of two malingering tests, the newly developed Amsterdam Short-Term Memory (ASTM) test and the Distraction test (Baker, Hanley, Jackson, Kimmance, & Slade, 1993) was examined in a group of patients with closed-head injury (CHI), a normal control group, and a control group with

  6. Hydrogen Field Test Standard: Laboratory and Field Performance

    Science.gov (United States)

    Pope, Jodie G.; Wright, John D.

    2015-01-01

    The National Institute of Standards and Technology (NIST) developed a prototype field test standard (FTS) that incorporates three test methods that could be used by state weights and measures inspectors to periodically verify the accuracy of retail hydrogen dispensers, much as gasoline dispensers are tested today. The three field test methods are: 1) gravimetric, 2) Pressure, Volume, Temperature (PVT), and 3) master meter. The FTS was tested in NIST's Transient Flow Facility with helium gas and in the field at a hydrogen dispenser location. All three methods agree within 0.57 % and 1.53 % for all test drafts of helium gas in the laboratory setting and of hydrogen gas in the field, respectively. The time required to perform six test drafts is similar for all three methods, ranging from 6 h for the gravimetric and master meter methods to 8 h for the PVT method. The laboratory tests show that 1) it is critical to wait for thermal equilibrium to achieve density measurements in the FTS that meet the desired uncertainty requirements for the PVT and master meter methods; in general, we found a wait time of 20 minutes introduces errors methods, respectively and 2) buoyancy corrections are important for the lowest uncertainty gravimetric measurements. The field tests show that sensor drift can become a largest component of uncertainty that is not present in the laboratory setting. The scale was calibrated after it was set up at the field location. Checks of the calibration throughout testing showed drift of 0.031 %. Calibration of the master meter and the pressure sensors prior to travel to the field location and upon return showed significant drifts in their calibrations; 0.14 % and up to 1.7 %, respectively. This highlights the need for better sensor selection and/or more robust sensor testing prior to putting into field service. All three test methods are capable of being successfully performed in the field and give equivalent answers if proper sensors without drift are

  7. Standard test method for plutonium assay by plutonium (III) diode array spectrophotometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method describes the determination of total plutonium as plutonium(III) in nitrate and chloride solutions. The technique is applicable to solutions of plutonium dioxide powders and pellets (Test Methods C 697), nuclear grade mixed oxides (Test Methods C 698), plutonium metal (Test Methods C 758), and plutonium nitrate solutions (Test Methods C 759). Solid samples are dissolved using the appropriate dissolution techniques described in Practice C 1168. The use of this technique for other plutonium-bearing materials has been reported (1-5), but final determination of applicability must be made by the user. The applicable concentration range for plutonium sample solutions is 10–200 g Pu/L. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropria...

  8. Standard test method for conducting drop-weight test to determine nil-ductility transition temperature of ferritic steels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers the determination of the nil-ductility transition (NDT) temperature of ferritic steels, 5/8 in. (15.9 mm) and thicker. 1.2 This test method may be used whenever the inquiry, contract, order, or specification states that the steels are subject to fracture toughness requirements as determined by the drop-weight test. 1.3 The values stated in inch-pound units are to be regarded as the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  9. Experimental test of the renormalizability consequences of the standard electroweak theory

    International Nuclear Information System (INIS)

    Bardin, D.Yu.

    1984-01-01

    The present status of the one-loop radiative corrections calculations in the standard electroweak theory is discussed. The possibilities of experimental tests of the higher order predictions of the standard theory is analysed in view of recent data, inclu-ing CERN p anti pcolcider data on Msub(W) and Msub(Z) measurement. The perspectives of these tests in the near future experiments are discussed

  10. Consistency test of the standard model

    International Nuclear Information System (INIS)

    Pawlowski, M.; Raczka, R.

    1997-01-01

    If the 'Higgs mass' is not the physical mass of a real particle but rather an effective ultraviolet cutoff then a process energy dependence of this cutoff must be admitted. Precision data from at least two energy scale experimental points are necessary to test this hypothesis. The first set of precision data is provided by the Z-boson peak experiments. We argue that the second set can be given by 10-20 GeV e + e - colliders. We pay attention to the special role of tau polarization experiments that can be sensitive to the 'Higgs mass' for a sample of ∼ 10 8 produced tau pairs. We argue that such a study may be regarded as a negative selfconsistency test of the Standard Model and of most of its extensions

  11. Standard Test Method for Testing Polymeric Seal Materials for Geothermal and/or High Temperature Service Under Sealing Stress

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This test method covers the initial evaluation of (screening) polymeric materials for seals under static sealing stress and at elevated temperatures. 1.2 This test method applies to geothermal service only if used in conjunction with Test Method E 1068. 1.3 The test fluid is distilled water. 1.4 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  12. Standard Guide for Testing Materials for Aerospace Plastic Transparent Enclosures

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This guide is intended to summarize the standard test methods available on individual and composite materials utilized in fabrication of aerospace plastic transparent enclosures. As such, it is intended to specifically include transparent thermoplastics, transparent elastomers, and reinforced plastics, whether thermoplastic or thermosetting. 1.2 This guide is intended as an aid in the search for test methods pertinent to Aerospace Plastic Transparent Enclosures. It should be understood that all methods listed may not apply to all enclosures. 1.3 The standards included refer to the properties or aspects listed in Table 1. The properties or aspects are listed in alphabetical order and the descriptions used are intended to facilitate the search. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limi...

  13. A standardization of the physical tests for external irradiation measuring detectors

    International Nuclear Information System (INIS)

    1977-05-01

    This report is the result of a standardization work, realized within the Radioprotection Services of the A.E.C., of the physical tests for dectors measuring external irradiations. Among the various tests mentionned, calibration and the establishment of the relative spectral response are treated in details. As far as calibration is concerned, the standardization refers to: the reference detector, the reference radiation source, the installation and calibration procedure. As for the relative spectral response the standardization refers to: the reference detector, the radiation sources to be used. High flux detectors and those for pulse electromagnetic radiations are also dealt with [fr

  14. 77 FR 26989 - Commercial Driver's License Testing and Commercial Learner's Permit Standards

    Science.gov (United States)

    2012-05-08

    ... [Docket No. FMCSA-2007-27659] RIN 2126-AB02 Commercial Driver's License Testing and Commercial Learner's... effective on July 8, 2011. That final rule amended the commercial driver's license (CDL) knowledge and skills testing standards and established new minimum Federal standards for States to issue the commercial...

  15. Short-term static corrosion tests in lead-bismuth

    Science.gov (United States)

    Soler Crespo, L.; Martín Muñoz, F. J.; Gómez Briceño, D.

    2001-07-01

    Martensitic steels have been proposed to be used as structural materials and as spallation target window in hybrid systems devoted to the transmutation of radioactive waste of long life and high activity. However, their compatibility with lead-bismuth in the operating conditions of these systems depends on the existence of a protective layer such as an oxide film. The feasibility of forming and maintaining an oxide layer or maintaining a pre-oxidised one has been studied. Martensitic steel F82Hmod. (8% Cr) has been tested in lead-bismuth under static and isothermal conditions at 400°C and 600°C. In order to study the first stages of the interaction between the steel and the eutectic, short-term tests (100 and 665 h) have been carried out. Pre-oxidised and as-received samples have been tested in atmospheres with different oxidant potential. For low oxygen concentration in lead-bismuth due to unexpected oxygen consumption in the experimental device, dissolution of as-received F82Hmod. occurs and pre-oxidation does not prevent the material dissolution. For high oxygen concentration, the pre-oxidation layer seems to improve the feasibility of protecting stainless steels controlling the oxygen potential of lead-bismuth with a gas phase.

  16. Short-term static corrosion tests in lead-bismuth

    International Nuclear Information System (INIS)

    Soler Crespo, L.; Martin Munoz, F.J.; Gomez Briceno, D.

    2001-01-01

    Martensitic steels have been proposed to be used as structural materials and as spallation target window in hybrid systems devoted to the transmutation of radioactive waste of long life and high activity. However, their compatibility with lead-bismuth in the operating conditions of these systems depends on the existence of a protective layer such as an oxide film. The feasibility of forming and maintaining an oxide layer or maintaining a pre-oxidised one has been studied. Martensitic steel F82Hmod. (8% Cr) has been tested in lead-bismuth under static and isothermal conditions at 400 o C and 600 o C. In order to study the first stages of the interaction between the steel and the eutectic, short-term tests (100 and 665 h) have been carried out. Pre-oxidised and as-received samples have been tested in atmospheres with different oxidant potential. For low oxygen concentration in lead-bismuth due to unexpected oxygen consumption in the experimental device, dissolution of as-received F82Hmod. occurs and pre-oxidation does not prevent the material dissolution. For high oxygen concentration, the pre-oxidation layer seems to improve the feasibility of protecting stainless steels controlling the oxygen potential of lead-bismuth with a gas phase

  17. Standard (60 Gy) or Short-Course (40 Gy) Irradiation Plus Concomitant and Adjuvant Temozolomide for Elderly Patients With Glioblastoma: A Propensity-Matched Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Minniti, Giuseppe, E-mail: gminniti@ospedalesantandrea.it [Radiation Oncology Unit, Sant' Andrea Hospital, University Sapienza, Rome (Italy); Scientific Institute for Research, Hospitalization and Health Care (IRCCS) Neuromed, Pozzilli (Italy); Scaringi, Claudia [Radiation Oncology Unit, Sant' Andrea Hospital, University Sapienza, Rome (Italy); Lanzetta, Gaetano [Scientific Institute for Research, Hospitalization and Health Care (IRCCS) Neuromed, Pozzilli (Italy); Terrenato, Irene [Biostatistic Unit, Regina Elena National Cancer Institute, Rome (Italy); Esposito, Vincenzo; Arcella, Antonella [Scientific Institute for Research, Hospitalization and Health Care (IRCCS) Neuromed, Pozzilli (Italy); Pace, Andrea [Neurology Unit, Regina Elena National Cancer Institute, Rome (Italy); Giangaspero, Felice [Scientific Institute for Research, Hospitalization and Health Care (IRCCS) Neuromed, Pozzilli (Italy); Bozzao, Alessandro [Neuroradiology Unit, Sant' Andrea Hospital, University Sapienza, Rome (Italy); Enrici, Riccardo Maurizi [Radiation Oncology Unit, Sant' Andrea Hospital, University Sapienza, Rome (Italy)

    2015-01-01

    Purpose: To evaluate 2 specific radiation schedules, each combined with temozolomide (TMZ), assessing their efficacy and safety in patients aged ≥65 years with newly diagnosed glioblastoma (GBM). Methods and Materials: Patients aged ≥65 years with Karnofsky performance status (KPS) ≥60 who received either standard (60 Gy) or short-course (40 Gy) radiation therapy (RT) with concomitant and adjuvant TMZ between June 2004 and October 2013 were retrospectively analyzed. A propensity score analysis was executed for a balanced comparison of treatment outcomes. Results: A total of 127 patients received standard RT-TMZ, whereas 116 patients underwent short-course RT-TMZ. Median overall survival and progression-free survival times were similar: 12 months and 5.6 months for the standard RT-TMZ group and 12.5 months and 6.7 months for the short-course RT-TMZ group, respectively. Radiation schedule was associated with similar survival outcomes in either unadjusted or adjusted analysis. O{sup 6}-methylguanine-DNA methyltransferase promoter methylation was the most favorable prognostic factor (P=.0001). Standard RT-TMZ therapy was associated with a significant rise in grade 2 and 3 neurologic toxicity (P=.01), lowering of KPS scores during the study (P=.01), and higher posttreatment dosing of corticosteroid (P=.02). Conclusions: In older adults with GBM, survival outcomes of standard and short-course RT-TMZ were similar. An abbreviated course of RT plus TMZ may represent a reasonable therapeutic approach for these patients, without loss of survival benefit and acceptable toxicity.

  18. An inspection standard of fuel for the high temperature engineering test reactor

    International Nuclear Information System (INIS)

    Kobayashi, Fumiaki; Shiozawa, Shusaku; Sawa, Kazuhiro; Sato, Sadao; Hayashi, Kimio; Fukuda, Kosaku; Kaneko, Mitsunobu; Sato, Tsutomu.

    1992-06-01

    The High Temperature Engineering Test Reactor (HTTR) uses the fuel comprising coated fuel particles. A general inspection standard for the coated particle fuel, however, has not been established in Japan. Therefore, it has been necessary to prescribe the inspection standard of the fuel for HTTR. Under these circumstances, a fuel inspection standard of HTTR has been established under cooperation of fuel specialists both inside and outside of JAERI on referring to the inspection methods adopted in USA, Germany and Japan for HTGR fuels. Since a large number of coated fuel particle samples is needed to inspect the HTTR fuel, the sampling inspection standard has also been established considering the inspection efficiency. This report presents the inspection and the sampling standards together with an explanation of these standards. These standards will be applied to the HTTR fuel acceptance tests. (author)

  19. Vietnamese validation of the short version of Internet Addiction Test

    OpenAIRE

    Tran, Bach Xuan; Mai, Hue Thi; Nguyen, Long Hoang; Nguyen, Cuong Tat; Latkin, Carl A.; Zhang, Melvyn W.B.; Ho, Roger C.M.

    2017-01-01

    Background and aims: The main goal of the present study was to examine the psychometric properties of a Vietnamese version of the short-version of Internet Addiction Test (s-IAT) and to assess the relationship between s-IAT scores and demographics, health related qualify of life and perceived stress scores in young Vietnamese. Methods: The Vietnamese version of s-IAT was administered to a sample of 589 participants. Exploratory factor and reliability analyses were performed. Regression analys...

  20. Scoliosis short-term rehabilitation (SSTR according to 'Best Practice' standards - are the results repeatable?

    Directory of Open Access Journals (Sweden)

    Borysov Maksym

    2012-01-01

    Full Text Available Abstract Claims have been made in a pilot study that a new form of short-term rehabilitation according to 'Best Practice' standards would change signs and symptoms of patients with scoliosis in the short-term. Aim of this study is to repeat the study published 2010 with a larger sample of patients using the same protocol. Both authors have undergone training in this special approach to scoliosis rehabilitation in 2010. Materials and methods 34 patients with Adolescent Idiopathic Scoliosis (AIS, 32 girls and 2 boys, average age 13.7 years and an average Cobb angle of 28.7 degrees (21-43 degrees underwent Scoliosis Short-Term Rehabilitation (SSTR of seven days. Two days with an intensity of 3 × 90 min sessions/day, and five days with an intensity of 2 × 60 min sessions/day. Angle of trunk rotation (ATR was measured before and after the time of treatment as well as the active correctability of the ATR after the programme as it has been done in the pilot investigation. Additionally to that, we also recorded the changes in Vital Capacity (VC before and after the programme. Results ATR was reduced significantly from 11,5 degrees to 8,4 degrees, the active correctability as measured with the Scoliometer (TM was also reduced significantly from the ATR after treatment 8,9 degrees to 6,5 degrees in the patients with thoracic curves. VC improved significantly (P Discussion The results achieved in the pilot investigation published previously are repeatable. The deformity of the trunk can be reduced significantly after SSTR. During the pilot study VC was not investigated. In our study VC improved significantly. Therefore, also shorter rehabilitation times with an appropriate programme seem to be able to change signs and symptoms of a patient with scoliosis. Like the out-patient Schroth programme as described in a study from Turkey, the SSTR provides benefits leading to an improvement of the condition. Conclusion Out-patient rehabilitation following the

  1. NedWind 25 Blade Testing at NREL for the European Standards Measurement and Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    Larwood, S.; Musial, W.; Freebury, G.; Beattie, A.G.

    2001-04-19

    In the mid-90s the European community initiated the Standards, Measurements, and Testing (SMT) program to harmonize testing and measurement procedures in several industries. Within the program, a project was carried out called the European Wind Turbine Testing Procedure Development. The second part of that project, called Blade Test Methods and Techniques, included the United States and was devised to help blade-testing laboratories harmonize their testing methods. This report provides the results of those tests conducted by the National Renewable Energy Laboratory.

  2. Standard test method for calibration of surface/stress measuring devices

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    Return to Contents page 1.1 This test method covers calibration or verification of calibration, or both, of surface-stress measuring devices used to measure stress in annealed and heat-strengthened or tempered glass using polariscopic or refractometry based principles. 1.2 This test method is nondestructive. 1.3 This test method uses transmitted light, and therefore, is applicable to light-transmitting glasses. 1.4 This test method is not applicable to chemically tempered glass. 1.5 Using the procedure described, surface stresses can be measured only on the “tin” side of float glass. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. Evaluation of NASA Foodbars as a Standard Diet for Use in Short-Term Rodent Space Flight Studies

    Science.gov (United States)

    Tou, Janet; Grindeland, Richard; Barrett, Joyce; Dalton, Bonnie; Mandel, Adrian; Wade, Charles

    2003-01-01

    A standard rodent diet for space flight must meet the unique conditions imposed by the space environment and must be nutritionally adequate since diet can influence the outcome of experiments. This paper evaluates the use of National Aeronautics and Space Administration (NASA) developed Foodbars as a standard space flight diet for rats. The Foodbar's semi-purified formulation permits criteria such as nutrient consistency, high nutrient bioavailability and flexibility of formulation to be met. Extrusion of the semi-purified diet produces Foodbars with the proper texture and a non-crumbing solid form for use in space. Treatment of Foodbar with 0.1% potassium sorbate prevents mold growth. Irradiation (15-25 kGy) prevents bacterial growth and in combination with sorbate-treatment provides added protection against mold for shelf-stability. However, during the development process, nutrient analyses indicated that extrusion and irradiation produced nutrient losses. Nutrients were adjusted accordingly to compensate for processing losses. Nutrient analysis of Foodbars continues to be performed routinely to monitor nutrient levels. It is important that the standard rodent diet provide nutrients that will prevent deficiency but also avoid excess that may mask physiological changes produced by space flight. All vitamins levels in the Foodbars, except for vitamin K conformed to or exceeded the current NRC (1995) recommendations. All indispensable amino acids in Foodbar conformed to or exceeded the NRC nutrient recommendation for mice growth and rat maintenance. However, some indispensable amino acids were slightly below recommendations for rat reproduction/growth. Short-term (18-20 d) animal feeding studies indicated that Foodbars were palatable, supported growth and maintained health in rats. Results indicated that NASA rodent Foodbars meet both the physical and nutritional criteria required to support rodents in the space environment and thus, may be used successfully as a

  4. Temporal stability of the Francis Scale of Attitude toward Christianity short-form: test-retest data over one week.

    Science.gov (United States)

    Lewis, Christopher Alan; Cruise, Sharon Mary; McGuckin, Conor

    2005-04-01

    This study evaluated the test-retest reliability of the Francis Scale of Attitude toward Christianity short-form. 39 Northern Irish undergraduate students completed the measure on two occasions separated by one week. Stability across the two administrations was high, r = .92, and there was no significant change between Time 1(M = 25.2, SD = 5.4) and Time 2 (M = 25.7, SD = 6.2). These data support the short-term test-retest reliability of the Francis Scale of Attitude toward Christianity short-form.

  5. A Methodological Approach for Testing the Viability of Seeds Stored in Short-Term Seed Banks

    Directory of Open Access Journals (Sweden)

    Jose A. FORTE GIL

    2017-12-01

    Full Text Available Efficient management of ‘active’ seed banks – specifically aimed at the short-term storage at room temperature of seeds to be used locally in conservation/regeneration programmes of endemic or endangered plant species – requires establishing the optimal storage time to maintain high seed viability, for each stored species. In this work, germination of seeds of the halophytes Thalictrum maritimum, Centaurea dracunculifolia and Linum maritimum has been investigated. The seeds had been stored for different periods of time in the seed bank of ‘La Albufera’ Natural Park (Valencia, SE Spain after collection in salt marshes of the Park, where small populations of the three species are present. Seeds of T. maritimum and C. dracunculifolia have a relatively short period of viability at room temperature, and should not be stored for more than three years. On the other hand, L. maritimum seeds maintain a high germination percentage and can be kept at room temperature for up to 10 years. T. maritimum seeds, in contrast to those of the other two species, did not germinate in in vitro tests nor when sown directly on a standard substrate, unless a pre-treatment of the seeds was applied, mechanical scarification being the most effective. These results will help to improve the management of the seed bank, to generate more efficiently new plants for reintroduction and reinforcement of populations of these species in their natural ecosystems within the Natural Park.

  6. Do Standardized Tests Penalize Deep-Thinking, Creative, or Conscientious Students?: Some Personality Correlates of Graduate Record Examinations Test Scores

    Science.gov (United States)

    Powers, Donald E.; Kaufman, James C.

    2004-01-01

    The objective of the study reported here was to explore the relationship of Graduate Record Examinations (GRE) General Test scores to selected personality traits--conscientiousness, rationality, ingenuity, quickness, creativity, and depth. A sample of 342 GRE test takers completed short personality inventory scales for each trait. Analyses…

  7. Similar tests and the standardized log likelihood ratio statistic

    DEFF Research Database (Denmark)

    Jensen, Jens Ledet

    1986-01-01

    When testing an affine hypothesis in an exponential family the 'ideal' procedure is to calculate the exact similar test, or an approximation to this, based on the conditional distribution given the minimal sufficient statistic under the null hypothesis. By contrast to this there is a 'primitive......' approach in which the marginal distribution of a test statistic considered and any nuisance parameter appearing in the test statistic is replaced by an estimate. We show here that when using standardized likelihood ratio statistics the 'primitive' procedure is in fact an 'ideal' procedure to order O(n -3...

  8. Standard Test Method for Gel Time of Carbon Fiber-Epoxy Prepreg

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers the determination of gel time of carbon fiber-epoxy tape and sheet. The test method is suitable for the measurement of gel time of resin systems having either high or low viscosity. 1.2 The values stated in SI units are to be regarded as standard. The values in parentheses are for reference only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  9. Pilot test of ANSI draft standard N13.29 environmental dosimetry -- Performance criteria for testing

    International Nuclear Information System (INIS)

    Klemic, G.; Shebell, P.; Monetti, M.; Raccah, F.; Sengupta, S.

    1998-09-01

    American National Standards Institute Draft N13.29 describes performance tests for environmental radiation dosimetry providers. If approved it would be the first step toward applying the types of performance testing now required in personnel dosimetry to environmental radiation monitoring. The objective of this study was to pilot test the draft standard, before it undergoes final balloting, on a small group of dosimetry providers that were selected to provide a mix of facility types, thermoluminescent dosimeter designs and monitoring program applications. The first phase of the pilot test involved exposing dosimeters to laboratory photon, beta, and x-ray sources at routine and accident dose levels. In the second phase, dosimeters were subjected to ninety days of simulated environmental conditions in an environmental chamber that cycled through extremes of temperature and humidity. Two out of seven participants passed all categories of the laboratory testing phase, and all seven passed the environmental test phase. While some relatively minor deficiencies were uncovered in the course of the pilot test, the results show that draft N13.29 describes useful tests that could be appropriate for environmental dosimetry providers. An appendix to this report contains recommendations that should be addressed by the N13.29 working group before draft N13.29 is submitted for balloting

  10. Legal standard of care: a shift from the traditional Bolam test.

    Science.gov (United States)

    Samanta, Ash; Samanta, Jo

    2003-01-01

    An essential component of an action in negligence against a doctor is proof that the doctor failed to provide the required standard of care under the circumstances. Traditionally the standard of care in law has been determined according to the Bolam test. This is based on the principle that a doctor does not breach the legal standard of care, and is therefore not negligent, if the practice is supported by a responsible body of similar professionals. The Bolam principle, however, has been perceived as being excessively reliant upon medical testimony supporting the defendant. The judgment given by the House of Lords in the recent case of Bolitho imposes a requirement that the standard proclaimed must be justified on a logical basis and must have considered the risks and benefits of competing options. The effect of Bolitho is that the court will take a more enquiring stance to test the medical evidence offered by both parties in litigation, in order to reach its own conclusions. Recent case law shows how the court has applied the Bolitho approach in determining the standard of care in cases of clinical negligence. An understanding of this approach and of the shift from the traditional Bolam test is relevant to all medical practitioners, particularly in a climate that is increasingly litigious.

  11. Standardized Testing Practices: Effect on Graduation and NCLEX® Pass Rates.

    Science.gov (United States)

    Randolph, Pamela K

    The use standardized testing in pre-licensure nursing programs has been accompanied by conflicting reports of effective practices. The purpose of this project was to describe standardized testing practices in one states' nursing programs and discover if the use of a cut score or oversight of remediation had any effect on (a) first time NCLEX® pass rates, (b) on-time graduation (OTG) or (c) the combination of (a) and (b). Administrators of 38 nursing programs in one Southwest state were sent surveys; surveys were returned by 34 programs (89%). Survey responses were compared to each program's NCLEX pass rate and on-time graduation rate; t-tests were conducted for significant differences associated with a required minimum score (cut score) and oversight of remediation. There were no significant differences in NCLEX pass or on-time graduation rates related to establishment of a cut score. There was a significant difference when the NCLEX pass rate and on-time graduation rate were combined (Outcome Index "OI") with significantly higher program outcomes (P=.02.) for programs without cut-scores. There were no differences associated with faculty oversight of remediation. The results of this study do not support establishment of a cut-score when implementing a standardized testing. Copyright © 2016. Published by Elsevier Inc.

  12. Experimental tests of induced spatial incoherence using short laser wavelength

    International Nuclear Information System (INIS)

    Obenschain, S.P.; Grun, J.; Herbst, M.J.

    1986-01-01

    The authors have developed a laser beam smoothing technique called induced spatial incoherence (ISI), which can produce the highly uniform focal profiles required for direct-drive laser fusion. Uniform well-controlled focal profiles are required to obtain the highly symmetric pellet implosions needed for high-energy gain. In recent experiments, the authors' tested the effects of ISI on high-power laser-target interaction. With short laser wavelength, the coupling physics dramatically improved over that obtained with an ordinary laser beam

  13. Short-circuit tests of 1650 and 96 MVA transformers for 1300 MW french nuclear power plants

    International Nuclear Information System (INIS)

    Mailhot, M.

    1989-01-01

    Power evacuation and feeding of the auxiliaries directly from the 400 kV grid are sensitive points governing the security of 1300 MW PWR Nuclear Power Plants of the French Program. These two different functions are provided by two specific types of transformers. - Banks of 3 single-phase 550 MVA - 400 kV/20 kV transformers. - Three-phase 96 MVA - 400 kV / 3 x 6.8 kV transformers. These passive elements must have a never failing reliability and assure a continuous service in spite of electric, thermal and mechanical stresses that may occur during the lifetime of the power plant. Dielectric and thermal tests carried out in the manufacturers test floors insure these stresses withstand capabilities of transformers. In France, high short-circuit power for the 400 kV network added to often low impedance voltages for transformers impose on them very high stresses during short-circuits. Calculation and experimentation on scale or partial models are not sufficient to insure short-circuit currents withstand capabilities of transformers. The margin of uncertainty dependent on obligatory extrapolations for this kind of complex systems [steel, magnetic sheets, copper, oil, paper and transformerboard] can be reduced in a significant way only by real scale tests on prototypes. These tests that need both high power and voltage cannot be performed in manufacturers test floors. So, in France they are carried out at the EDF Les Renardieres Laboratory. Following paper deals with SHELL TYPE TRANSFORMERS which, particularly thanks to their interleaved rectangular windings display a great resistance to short-circuit stresses

  14. Short term mutagenicity tests and their application to irradiated foods

    International Nuclear Information System (INIS)

    Phillips, B.J.; Elias, P.S.

    1980-01-01

    Although traditional long-term animal tests are likely to continue to be required, these are not only extremely costly but are coming more and more to be recognised as an imprecise and unsatisfactory method of testing the safety of irradiated foods for human consumption. It is therefore clearly advisable to include a selection of quicker and more direct testing methods in any toxicological assessment procedures. The International Project has therefore undertaken a study of the feasibility of using the newer systems for investigation of irradiated foodstuffs. Although some work in this field has already been carried out, some shortcomings in the published work can be identified which justify a more detailed and intensive research programme. As expected, little difficulty has been encountered in testing food by methods involving mammals, but considerable effort has been required to adapt in vitro systems. The use of enzymatic digestion in vitro to provide food samples for testing in mammalian cell cultures has never been attempted before and the procedures developed by the Project represent a positive contribution to methodology in this field. A series of foodstuffs is being tested by a wide spectrum of short-term tests and the first results are now being obtained. (orig./MG) [de

  15. 78 FR 34423 - Aviation Rulemaking Advisory Committee (ARAC) Airman Testing Standards and Training Working Group...

    Science.gov (United States)

    2013-06-07

    ... the relevance, reliability, validity, and effectiveness of the FAA's aeronautical testing and training... Rulemaking Advisory Committee (ARAC) Airman Testing Standards and Training Working Group (ATSTWG) AGENCY... Certification Standards (ACS) documents developed by the Airman Testing Standards and Training WG for the...

  16. The short-circuit test results of 6.9 kV/2.3 kV 400 kVA-class YBCO model transformer

    International Nuclear Information System (INIS)

    Tomioka, A.; Otonari, T.; Ogata, T.; Iwakuma, M.; Okamoto, H.; Hayashi, H.; Iijima, Y.; Saito, T.; Gosho, Y.; Tanabe, K.; Izumi, T.; Shiohara, Y.

    2011-01-01

    The 6.9 kV/2.3 kV 400 kVA-class single-phase YBCO model transformer with the YBCO tape with copper tape was manufactured for short-circuit current test. Short-circuit test was performed and the short-circuit current of primary winding was 346 A which was about six times larger than the rated current. The I-V characteristics of the winding did not change before and after the test. The transformer withstood short-circuit current. We are planning to turn the result into a consideration of a 66 kV/6.9 kV-20 MVA-class three-phase superconducting transformer. We are developing an elemental technology for 66 kV/6.9 kV 20 MVA-class power transformer with YBCO conductors. The protection of short-circuit technology is one of the elemental technologies for HTS transformer. Since short-circuit current is much higher than critical current of YBCO tape, there is a possibility that superconducting characteristics may be damaged during short-circuit period. We made a conductor to compose the YBCO tape with copper tape. We manufactured 6.9 kV/2.3 kV 400 kVA-class YBCO model transformer using this conductor and performed short-circuit current test. The short-circuit current of primary winding was 346 A which was about six times larger than the rated current. The I-V characteristics of the winding did not change before and after the test. We may consider this conductor withstands short-circuit current.

  17. Standard test method for measuring waste glass or glass ceramic durability by vapor hydration test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 The vapor hydration test method can be used to study the corrosion of a waste forms such as glasses and glass ceramics upon exposure to water vapor at elevated temperatures. In addition, the alteration phases that form can be used as indicators of those phases that may form under repository conditions. These tests; which allow altering of glass at high surface area to solution volume ratio; provide useful information regarding the alteration phases that are formed, the disposition of radioactive and hazardous components, and the alteration kinetics under the specific test conditions. This information may be used in performance assessment (McGrail et al, 2002 (1) for example). 1.2 This test method must be performed in accordance with all quality assurance requirements for acceptance of the data. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practice...

  18. Physiological testing of basketball players: toward a standard evaluation of anaerobic fitness.

    Science.gov (United States)

    Delextrat, Anne; Cohen, Daniel

    2008-07-01

    The aim of this study was to examine whether the changes in the rules of the game instituted in 2000 have modified the physiological factors of success in basketball. The performances of 8 elite male players and 8 average-level players were compared in order to identify which components of fitness among agility, speed, anaerobic power, anaerobic capacity, and upper body strength were key determinants of performance in modern basketball. Each subject performed 7 tests, including vertical jump (VJ), 20-m sprint, agility T test, suicide sprint, 30-second Wingate anaerobic test (WAnT), isokinetic testing of the knee extensors, and 1 repetition maximum (1RM) bench press test. The statistical difference in the anaerobic performances was assessed by Student's t test. The main results showed that, compared to average-level players, elite-level players achieved significantly better performances in the agility T test (+6.2%), VJ test (+8.8%), peak torques developed by knee extensors (+20.2%), and 1RM bench press (+18.6%, p 0.05). These results emphasized the importance of anaerobic power in modern basketball, whereas anaerobic capacity does not seem to be a key aspect to consider. In this context, coaches are advised to avoid using exercises lasting >/=30 seconds in their physical fitness programs, but instead to focus on short and intense tests such as VJ, agility T test, and sprints over very short distances (5 or 10 m).

  19. Analysis of standard problem six (Semiscale test S-02-6) data

    International Nuclear Information System (INIS)

    Cartmill, C.E.

    1977-08-01

    Test S-02-6 of the Semiscale Mod-1 blowdown heat transfer test series was conducted to supply data for the U.S. Nuclear Regulatory Commission Standard Problem Six. To determine the credibility of the data and thus establish the validity of Standard Problem Six, an analysis of the results of Test S-02-6 was performed and is presented. This analysis consisted of investigations of system hydraulic and core thermal data. The credibility of the system hydraulic data was investigated through comparisons of the data with data and calculations from related sources (Test S-02-4) and, when necessary, through assessment of physical events. The credibility of the core thermal data was based on a thorough analysis of physical events. The results of these investigations substantiate the validity of Test S-02-6 data

  20. The Vise/Vice of Standardized Testing: National Depreciation by Quantification.

    Science.gov (United States)

    Farrell, Edmund J.

    Current uses of standardized English tests are adversely affecting students, misleading lay people, and having a pernicious effect on the English profession. These tests are severely limited, incapable of assessing speaking skill and effectiveness, reading interests, appreciation of literature, listening skill, understanding and appreciation of…

  1. Ultrasonic transverse velocity calibration of standard blocks for use in non-destructive testing

    International Nuclear Information System (INIS)

    Silva, C E R; Braz, D S; Maggi, L E; Felix, R P B Costa

    2015-01-01

    Standard blocks are employed in the verification of the equipment used in Ultrasound Non-Destructive Testing. To assure the metrology reliability of all the measurement process, it is necessary to calibrate or certify these Standard blocks. In this work, the transverse wave velocity and main dimensions were assessed according to the specifications ISO Standards. For transverse wave velocity measurement, a 5 MHz transverse wave transducer, a waveform generator, an oscilloscope and a computer with a program developed in LabVIEW TM were used. Concerning the transverse wave velocity calibration, only two Standard blocks of the 4 tested is in accordance with the standard

  2. Review of short-term screening tests for mutagens, toxigens, and carcinogens

    Energy Technology Data Exchange (ETDEWEB)

    Carney, H.J.; Hass, B.S.

    1979-07-01

    In order to test the thousands of man-made chemicals in the environment for carcinogenic and genetic hazards, a multitude of short-term screening tests has been developed to complement long-term mammalian bioassays and epidemiological studies. These tests cover a broad spectrum of organisms, and include the use of naked and viral nucleic acids, bacteria, fungi, higher plants, insects in vitro mammalian cell cultures (cell transformation, cell-mediated mutagenesis, DNA repair, and chromosome aberration tests) and live mammals. Assay end points include effects on nucleic acids, DNA repair synthesis, point or gene mutation, structural and numerical chromosome aberrations, cytological alterations, and in vitro cell transformation. The present review describes and compares these assays. In addition, it discusses their historical development, the problems and limitations associated with their use, and their implementation in comprehensive testing programs. It is intended to provide overview and specific information to the laboratory that is in the process of establishing genetic toxicological systems. (The literature is reviewed to January 1978.)

  3. Development of a radionuclide short-test for the evaluation of engine oils in respect to cam- and cylinder linear wear by using OM 616 Kombi-Test conditions

    International Nuclear Information System (INIS)

    Volz, J.; Lausch, W.

    1980-05-01

    A survey is given on the studies performed since 1973 on the development of radionuclide short-test procedure, based on the test procedure of the OM 616 Kombi-Test, for the evaluation of engine oils in respect to cam- and cylinder liner wear (deuteron activated Co-56). Out of the results of these studies on experimental short test procedure has been elaborated to evaluate cylinder liner wear. With this experimental procedure some round robin testing has been carried out by three laboratories using a well-known reference oil and two test oils. The results of this round robin test led to further improvements in the test procedure. This improved test procedure has become a suitable screening-test for the development of engine oils in respect to cylinder liner wear. It never can replace the OM 616-Kombi-Test as a whole, but it will complete it. The radionuclide short test gets results quicker and at lower costs than the Kombi-Test, discriminates between hot test and cold-warm test results, and gives results even with correlation to the Kombi-Test by comparison to an approved reference oil. For such screening work, the repeatability of the test is also sufficient. (orig./HP) [de

  4. Do School-Based Tutoring Programs Significantly Improve Student Performance on Standardized Tests?

    Science.gov (United States)

    Rothman, Terri; Henderson, Mary

    2011-01-01

    This study used a pre-post, nonequivalent control group design to examine the impact of an in-district, after-school tutoring program on eighth grade students' standardized test scores in language arts and mathematics. Students who had scored in the near-passing range on either the language arts or mathematics aspect of a standardized test at the…

  5. [Development and short-term effects of a standardized patient education program for in-patient cardiologic rehabilitation].

    Science.gov (United States)

    Seekatz, B; Haug, G; Mosler, G; Schwaab, B; Altstidl, R; Worringen, U; Faller, H; Meng, K

    2013-10-01

    Patient education is an essential part in the treatment of coronary heart disease in medical rehabilitation. In the German-speaking area, no standardized and evaluated patient education program for coronary heart disease is available so far. In this paper, we demonstrate the development of a quality assured patient education program based on a health-education program of the German statutory pension insurance scheme. In a multi-level approach, an existing program was modified concerning treatment evidence, practical guidelines, theories of health and illness behavior and quality criteria for patient education as well as clinical experience and thereafter manualized. In a formative evaluation, feasibility and patient acceptance of this modified program were assessed using evaluation questionnaires of patients and trainers. Afterwards, effects of the patient education program as compared to a traditional education program were assessed on a short-term (at discharge), medium-term (6-month follow-up) and long-term (12-month follow-up) basis in a multicenter quasi-experimental control group study of patients with coronary heart disease (n=434). Results of the formative evaluation demonstrate an overall good acceptance and a good feasibility of the manualized program. Short-term results show a significant small treatment effect in the primary outcome variable patients' knowledge (p=0.001, η2 =0.028). Furthermore, small effects were also observed among some secondary outcomes, such as attitude towards medication, planning of physical activity, psychological quality of life and satisfaction with the education program. A standardized education program for patients with coronary heart disease has been developed in a systematic process based on established quality standards. Depending on the outstanding medium and long-term effects, the program may be recommended for general use in medical rehabilitation. The manual provides the prerequisites allowing for a successful

  6. Outcome of tight versus standard glycemic control in coronary artery bypass patients

    International Nuclear Information System (INIS)

    Subhani, H.

    2012-01-01

    Objectives: To compare the outcome of tight versus standard glycemic control and its impact on post operative morbidity and short term mortality in patients undergoing Coronary Artery Bypass Grafting (CA-BG). Patients and Methods: A prospective surveillance of 124 patients undergoing isolated CABG surgery (on pump) was included in the study, 62 patients in each group were randomly assigned to tight and standard glucose control group. The main exposure was insulin in respect to level of blood glucose and the primary outcome measures were Sternotomy wound infection, Leg wound infection and new Myocardial Infarction. Surgical Site infection was assessed on a daily basis during the patient's stay in the Department of Cardio-thoracic Surgery, Sheikh Zayed Hospital, Lahore or within 30 days of operation prompting the patient to return to the hospital. Chi-square test or test was used to identify the significance of various short term morbidities and mortality. Results: In this study, 12 patients in the standard group and 4 patients in the tightly controlled group developed Sternal wound infection (p value 0.046). Similarly, 9 versus 2 patients in the standard and tight group respectively developed Leg wound infection (p-value 0.035). Test of proportion was applied and it was found that there was significant difference in the pro-portion of infection in the two groups (p value 0.05). However, there were no significant differences in other morbidities and the short term mortality. Conclusion: Study confirmed that tight glucose con-trol post operatively in CABG patient's results in reduced sternal and leg wound infection rates; however, there was no effect on other morbidities and short term mortality. (author)

  7. Fabrication and Testing of Pyramidal X- Band Standard Horn Antenna

    Directory of Open Access Journals (Sweden)

    Hasan F. Khazaal

    2017-11-01

    Full Text Available Standard horn antennas are an important device to evaluate many types of antennas, since they are used as a reference to any type of antennas within the microwave frequency bands. In this project the fabrication process and tests of standard horn antenna operating at X-band frequencies have been proposed. The fabricated antenna passed through multi stages of processing of its parts until assembling the final product. These stages are (milling, bending, fitting and welding. The assembled antenna subjected to two types of tests to evaluate its performance. The first one is the test by two port network analyzer to point out S & Z parameters, input resistance, and the voltage standing wave ratio of the horn, while the second test was done using un-echoic chamber to measure the gain, side lobes level and the half power beam width. The results of testing come nearly as a theoretical value of the most important of antenna parameters, like; gain, side lobe level, -3 dB beam width, return loss and voltage standing wave ratio "VSWR", input Impedance.

  8. Standard Test Method for Normal Spectral Emittance at Elevated Temperatures

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1972-01-01

    1.1 This test method describes a highly accurate technique for measuring the normal spectral emittance of electrically conducting materials or materials with electrically conducting substrates, in the temperature range from 600 to 1400 K, and at wavelengths from 1 to 35 μm. 1.2 The test method requires expensive equipment and rather elaborate precautions, but produces data that are accurate to within a few percent. It is suitable for research laboratories where the highest precision and accuracy are desired, but is not recommended for routine production or acceptance testing. However, because of its high accuracy this test method can be used as a referee method to be applied to production and acceptance testing in cases of dispute. 1.3 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this stan...

  9. Short Circuit Tests First Step of LHC Hardware Commissioning Completion

    CERN Document Server

    Barbero-Soto, E; Bordry, Frederick; Casas Lino, M P; Coelingh, G J; Cumer, G; Dahlerup-Petersen, K; Guillaume, J C; Inigo-Golfin, J; Montabonnet, V; Nisbet, D; Pojer, M; Principe, R; Rodríguez-Mateos, F; Saban, R; Schmidt, R; Thiesen, H; Vergara-Fernández, A; Zerlauth, M; Castaneda Serra, A; Romera Ramirez, I

    2008-01-01

    For the two counter rotating beams in the Large Hadron Collider (LHC) about 8000 magnets (main dipole and quadrupole magnets, corrector magnets, separation dipoles, matching section quadrupoles etc.) are powered in about 1500 superconducting electrical circuits. The magnets are powered by power converters that have been designed for the LHC with a current between 60 and 13000A. Between October 2005 and September 2007 the so-called Short Circuit Tests were carried-out in 15 underground zones where the power converters of the superconducting circuits are placed. The tests aimed to qualify the normal conducting equipments of the circuits such as power converters and normal conducting high current cables. The correct operation of interlock and energy extraction systems was validated. The infrastructure systems including AC distribution, water and air cooling and the control systems was also commissioned. In this paper the results of the two year test campaign are summarized with particular attention to problems e...

  10. Testing an extrapolation chamber in computed tomography standard beams

    Science.gov (United States)

    Castro, M. C.; Silva, N. F.; Caldas, L. V. E.

    2018-03-01

    The computed tomography (CT) is responsible for the highest dose values to the patients. Therefore, the radiation doses in this procedure must be accurate. However, there is no primary standard system for this kind of radiation beam yet. In order to search for a CT primary standard, an extrapolation ionization chamber built at the Calibration Laboratory (LCI) of the Instituto de Pesquisas Energéticas e Nucleares (IPEN), was tested in this work. The results showed to be within the international recommended limits.

  11. Standard Waste Box Lid Screw Removal Option Testing

    International Nuclear Information System (INIS)

    Anast, Kurt Roy

    2016-01-01

    This report provides results from test work conducted to resolve the removal of screws securing the standard waste box (SWB) lids that hold the remediated nitrate salt (RNS) drums. The test work evaluated equipment and process alternatives for removing the 42 screws that hold the SWB lid in place. The screws were secured with a red Loctite thread locker that makes removal very difficult because the rivets that the screw threads into would slip before the screw could be freed from the rivet, making it impossible to remove the screw and therefore the SWB lid.

  12. Standard Waste Box Lid Screw Removal Option Testing

    Energy Technology Data Exchange (ETDEWEB)

    Anast, Kurt Roy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-03-11

    This report provides results from test work conducted to resolve the removal of screws securing the standard waste box (SWB) lids that hold the remediated nitrate salt (RNS) drums. The test work evaluated equipment and process alternatives for removing the 42 screws that hold the SWB lid in place. The screws were secured with a red Loctite thread locker that makes removal very difficult because the rivets that the screw threads into would slip before the screw could be freed from the rivet, making it impossible to remove the screw and therefore the SWB lid.

  13. Vietnamese validation of the short version of Internet Addiction Test

    Directory of Open Access Journals (Sweden)

    Bach Xuan Tran

    2017-12-01

    Full Text Available Background and aims: The main goal of the present study was to examine the psychometric properties of a Vietnamese version of the short-version of Internet Addiction Test (s-IAT and to assess the relationship between s-IAT scores and demographics, health related qualify of life and perceived stress scores in young Vietnamese. Methods: The Vietnamese version of s-IAT was administered to a sample of 589 participants. Exploratory factor and reliability analyses were performed. Regression analysis was used to identify the associated factors. Results: The two-factor model of Vietnamese version of s-IAT demonstrated good psychometric properties. The internal consistency of Factor 1 (loss of control/time management was high (Cronbach's alpha=0.82 and Factor 2 (craving/social problems was satisfactory (Cronbach's alpha=0.75. Findings indicated that 20.9% youths were addicted to the Internet. Regression analysis revealed significant associations between Internet addiction and having problems in self-care, lower quality of life and high perceived stress scores. Discussion and conclusions: The Vietnamese version of s-IAT is a valid and reliable instrument to assess IA in Vietnamese population. Due to the high prevalence of IA among Vietnamese youths, IA should be paid attention in future intervention programs. s-IAT can be a useful screening tool for IA to promptly inform and treat the IA among Vietnamese youths. Keywords: Factor analysis, Short-version, Internet Addiction Test, Psychometric properties, Vietnamese

  14. MK-801 and memantine act differently on short-term memory tested with different time-intervals in the Morris water maze test.

    Science.gov (United States)

    Duda, Weronika; Wesierska, Malgorzata; Ostaszewski, Pawel; Vales, Karel; Nekovarova, Tereza; Stuchlik, Ales

    2016-09-15

    N-methyl-d-aspartate receptors (NMDARs) play a crucial role in spatial memory formation. In neuropharmacological studies their functioning strongly depends on testing conditions and the dosage of NMDAR antagonists. The aim of this study was to assess the immediate effects of NMDAR block by (+)MK-801 or memantine on short-term allothetic memory. Memory was tested in a working memory version of the Morris water maze test. In our version of the test, rats underwent one day of training with 8 trials, and then three experimental days when rats were injected intraperitoneally with low- 5 (MeL), high - 20 (MeH) mg/kg memantine, 0.1mg/kg MK-801 or 1ml/kg saline (SAL) 30min before testing, for three consecutive days. On each experimental day there was just one acquisition and one test trial, with an inter-trial interval of 5 or 15min. During training the hidden platform was relocated after each trial and during the experiment after each day. The follow-up effect was assessed on day 9. Intact rats improved their spatial memory across the one training day. With a 5min interval MeH rats had longer latency then all rats during retrieval. With a 15min interval the MeH rats presented worse working memory measured as retrieval minus acquisition trial for path than SAL and MeL and for latency than MeL rats. MK-801 rats had longer latency than SAL during retrieval. Thus, the high dose of memantine, contrary to low dose of MK-801 disrupts short-term memory independent on the time interval between acquisition and retrieval. This shows that short-term memory tested in a working memory version of water maze is sensitive to several parameters: i.e., NMDA receptor antagonist type, dosage and the time interval between learning and testing. Copyright © 2016. Published by Elsevier B.V.

  15. A Cross-Sectional Evaluation of Student Achievement Using Standardized and Performance-Based Tests

    Science.gov (United States)

    Pinter, Brad; Matchock, Robert L.; Charles, Eric P.; Balch, William R.

    2014-01-01

    Three groups of undergraduates (42 senior graduating psychology majors, 27 first-year premajors taking introductory psychology, and 24 first-year, high-performing nonmajors taking introductory psychology) completed the Psychology Major Field Test (MFT) and a short-answer (SA) essay test on reasoning about core knowledge in psychology. Graduating…

  16. Effects of Two Short-Term Desensitization Methods in the Treatment of Test Anxiety

    Science.gov (United States)

    Richardson, Frank C.; Suinn, Richard M.

    1974-01-01

    Accelerated massed desensitization and anxiety management training were compared with standard systematic desensitization in terms of reducing self-reported test anxiety in high test-anxious college students. All three treatments significantly reduced test anxiety as compared with a waiting list control group. (Author)

  17. Department of Energy standard for the performance testing of personnel dosimetry systems

    International Nuclear Information System (INIS)

    1986-12-01

    This standard is intended to be used in the Department of Energy Laboratory Accreditation Program (DOELAP) for personnel dosimetry systems. It is based on the American National Standards Institute's (ANSI) ''Criteria for Testing Personnel Dosimetry Performance,'' ANSI N13.11-1983, recommendations made to DOE in ''Guidelines for the Calibration of Personnel Dosimeters,'' Pacific Northwest Laboratory (PNL)-4515 and comments received during peer review by DOE and DOE contractor personnel. The recommendations contained in PNL-4515 were based on an evaluation of ANSI N13.11 conducted for the Office of Nuclear Safety, DOE, by PNL. Parts of ANSI N13.11 that did not require modification were used essentially intact in this standard to maintain consistency with nationally recognized standards. Modifications to this standard have resulted from several DOE/DOE contractor reviews and a pilot testing session. An initial peer review by selected DOE and DOE contractor representatives on technical content was conducted in 1983. A review by DOE field offices, program offices, and contractors was conducted in mid-1984. A pilot performance testing session sponsored by the Office of Nuclear Safety was conducted in early 1985 by the Radiological and Environmental Sciences Laboratory, Idaho Falls. Results of the pilot test were reviewed in late 1985 by a DOE and DOE contractor committee. 11 refs., 4 tabs

  18. Preliminary results of testing bioassay analytical performance standards

    International Nuclear Information System (INIS)

    Fisher, D.R.; Robinson, A.V.; Hadley, R.T.

    1983-08-01

    The analytical performance of both in vivo and in vitro bioassay laboratories is being studied to determine the capability of these laboratories to meet the minimum criteria for accuracy and precision specified in the draft ANSI Standard N13.30, Performance Criteria for Radiobioassay. This paper presents preliminary results of the first round of testing

  19. A single standard for in-place testing of DOE HEPA filters - not

    Energy Technology Data Exchange (ETDEWEB)

    Mokler, B.V. [Los Alamos National Laboratory, NM (United States)

    1995-02-01

    This article is a review of arguments against the use of a single standard for in-place testing of DOE HEPA filters. The author feels that the term `standard` entails mandatory compliance. Additionally, the author feels that the variety of DOE HEPA systems requiring in-place testing is such that the guidance for testing must be written in a permissive fashion, allowing options and alternatives. With this in mind, it is not possible to write a single document entailing mandatory compliance for all DOE facilities.

  20. Determination of material properties for short fibre reinforced C/C-SiC

    Directory of Open Access Journals (Sweden)

    Hausherr J.-M.

    2015-01-01

    Full Text Available Determining the mechanical properties of short fibre reinforced CMC using standard sized coupons has always been a challenge due to a high statistical scattering of the measured values. Although the random orientation of short fibres results in a quasi-isotropic material behavior of 2D-structures with a sufficiently large volume, the small volume typical for test coupons usually results in a non-isotropic fibre orientation in the tested volume. This paper describes a method for manufacturing unidirectional oriented short fibre reinforced CMC materials and presents material properties of UD-C/C-SiC. After verifying the fibre orientation of the CMC using micro-computed tomography, coupons were extracted to determine the orthotropic material properties. These orthotropic material properties were then used to predict the properties of C/C-SiC with randomly distributed short fibres. To validate the method, micro-computed tomography is used to quantitatively determine the fibre orientation within coupons extracted from randomly distributed short fibre C/C-SiC. After mechanical three-point-bending tests, the measured stiffness and bending strength is compared with the predicted properties. Finally, the data are used to devise a method suited for reducing the inherent large spread of material properties associated with the measurement of CMC materials with randomly distributed short fibres.

  1. Short-Run Contexts and Imperfect Testing for Continuous Sampling Plans

    Directory of Open Access Journals (Sweden)

    Mirella Rodriguez

    2018-04-01

    Full Text Available Continuous sampling plans are used to ensure a high level of quality for items produced in long-run contexts. The basic idea of these plans is to alternate between 100% inspection and a reduced rate of inspection frequency. Any inspected item that is found to be defective is replaced with a non-defective item. Because not all items are inspected, some defective items will escape to the customer. Analytical formulas have been developed that measure both the customer perceived quality and also the level of inspection effort. The analysis of continuous sampling plans does not apply to short-run contexts, where only a finite-size batch of items is to be produced. In this paper, a simulation algorithm is designed and implemented to analyze the customer perceived quality and the level of inspection effort for short-run contexts. A parameter representing the effectiveness of the test used during inspection is introduced to the analysis, and an analytical approximation is discussed. An application of the simulation algorithm that helped answer questions for the U.S. Navy is discussed.

  2. Educators Questioning Timing of State Tests Reflecting Standards

    Science.gov (United States)

    Gewertz, Catherine

    2013-01-01

    New York is ahead of most states in its work to design detailed curricula and professional development for the common core and to build brand-new tests to reflect them. What's unfolding in the Empire State as a result of that work illustrates the way the common standards can pressure changes in the education landscape, and torque the tensions…

  3. Standardization of food allergen extracts for skin prick test

    DEFF Research Database (Denmark)

    Skamstrup Hansen, K; Bindslev-Jensen, C; Skov, P S

    2001-01-01

    The aim of the study was to standardize and evaluate technically optimized food allergen extracts for use in skin prick test (SPT). The standardization procedure comprised 36 allergic histories in 32 food allergic patients with 21 healthy, non-atopic individuals serving as controls. The patients...... had a history of allergic symptoms upon ingestion of either cow's milk (n=3), hen's egg (n=9), wheat (n=4), hazelnut (n=14) or cod (n=6). They also had specific IgE in serum to the food in question and a positive SPT with a fresh preparation of the food. The diagnosis had been confirmed by a double......-blind, placebo-controlled food challenge, except for the hazelnut-allergic patients. The controls were subjected to an open food challenge with all the foods to ensure tolerance. The standardization was performed by means of titrated SPT in accordance with the guidelines on biological standardization from...

  4. Standard test method for compressive (crushing) strength of fired whiteware materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers two test procedures (A and B) for the determination of the compressive strength of fired whiteware materials. 1.2 Procedure A is generally applicable to whiteware products of low- to moderately high-strength levels (up to 150 000 psi or 1030 MPa). 1.3 Procedure B is specifically devised for testing of high-strength ceramics (over 100 000 psi or 690 MPa). 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. A Step Towards Electric Propulsion Testing Standards: Pressure Measurements and Effective Pumping Speeds

    Science.gov (United States)

    Dankanich, John W.; Swiatek, Michael W.; Yim, John T.

    2012-01-01

    The electric propulsion community has been implored to establish and implement a set of universally applicable test standards during the research, development, and qualification of electric propulsion systems. Existing practices are fallible and result in testing variations which leads to suspicious results, large margins in application, or aversion to mission infusion. Performance measurements and life testing under appropriate conditions can be costly and lengthy. Measurement practices must be consistent, accurate, and repeatable. Additionally, the measurements must be universally transportable across facilities throughout the development, qualification, spacecraft integration and on-orbit performance. A preliminary step to progress towards universally applicable testing standards is outlined for facility pressure measurements and effective pumping speed calculations. The standard has been applied to multiple facilities at the NASA Glenn Research Center. Test results and analyses of universality of measurements are presented herein.

  6. Standard Reference Test Method for Making Potentiostatic and Potentiodynamic Anodic Polarization Measurements

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This test method covers an experimental procedure for checking experimental technique and instrumentation. If followed, this test method will provide repeatable potentiostatic and potentiodynamic anodic polarization measurements that will reproduce data determined by others at other times and in other laboratories provided all laboratories are testing reference samples from the same lot of Type 430 stainless steel. 1.2 Values stated in SI units are to be regarded as the standard. Inch-pound units given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  7. New Standards for the Validation of EMC Test Sites particularly above 1 GHz

    Directory of Open Access Journals (Sweden)

    S. Battermann

    2005-01-01

    Full Text Available Standards for the validation of alternative test sites with conducting groundplane exist for the frequency range 30-1000 MHz since the end of the eighties. Recently the procedure for fully anechoic rooms (FAR has been included in CISPR 16 after more than 10 years intensive discussion in standards committees (CENELEC, 2002; CISPR, 2004. But there are no standards available for the validation of alternative test sites above 1 GHz. The responsible working group (WG1 in CISPR/A has drawn up the 7th common draft (CD. A CDV will be published in spring 2005. The German standards committee VDE AK 767.4.1 participates in the drafting of the standard. All suggested measurement procedures proposed in the last CDs have been investigated by measurements and theoretical analysis. This contribution describes the basic ideas and problems of the validation procedure of the test site. Furthermore measurement results and numerical calculations will be presented especially for the use of omni-directional antennas.

  8. Short and inflamed cervix predicts spontaneous preterm birth (COLIBRI study).

    Science.gov (United States)

    Raiche, Evelyne; Ouellet, Annie; Berthiaume, Maryse; Rousseau, Éric; Pasquier, Jean-Charles

    2014-07-01

    To develop a new strategy of predicting spontaneous preterm birth (sPTB) by combination of transvaginal ultrasound (TVUS) assessment and inflammatory proteins detection in vaginal secretions. Prospective study of 87 women referred for cervical length assessment with a standardized TVUS combined to vaginal secretions sampling. Samples were analyzed for presence of 10 cytokines. Main outcome was sPTB (women at a median gestational age of 35.6 weeks of gestation. Short cervix (women with a short inflamed cervix. COLIBRI study used a novel, single-step method of vaginal secretions sampling during TVUS and demonstrated that combination of short cervix and IL-8 in vaginal secretions is a promising sPTB predictive test.

  9. Empirical versus Random Item Selection in the Design of Intelligence Test Short Forms--The WISC-R Example.

    Science.gov (United States)

    Goh, David S.

    1979-01-01

    The advantages of using psychometric thoery to design short forms of intelligence tests are demonstrated by comparing such usage to a systematic random procedure that has previously been used. The Wechsler Intelligence Scale for Children Revised (WISC-R) Short Form is presented as an example. (JKS)

  10. Stress-testing the Standard Model at the LHC

    CERN Document Server

    2016-01-01

    With the high-energy run of the LHC now underway, and clear manifestations of beyond-Standard-Model physics not yet seen in data from the previous run, the search for new physics at the LHC may be a quest for small deviations with big consequences. If clear signals are present, precise predictions and measurements will again be crucial for extracting the maximum information from the data, as in the case of the Higgs boson. Precision will therefore remain a key theme for particle physics research in the coming years. The conference will provide a forum for experimentalists and theorists to identify the challenges and refine the tools for high-precision tests of the Standard Model and searches for signals of new physics at Run II of the LHC. Topics to be discussed include: pinning down Standard Model corrections to key LHC processes; combining fixed-order QCD calculations with all-order resummations and parton showers; new developments in jet physics concerning jet substructure, associated jets and boosted je...

  11. Difficulties Using Standardized Tests to Identify the Receptive Expressive Gap in Bilingual Children's Vocabularies.

    Science.gov (United States)

    Gibson, Todd A; Oller, D Kimbrough; Jarmulowicz, Linda

    2018-03-01

    Receptive standardized vocabulary scores have been found to be much higher than expressive standardized vocabulary scores in children with Spanish as L1, learning L2 (English) in school (Gibson et al., 2012). Here we present evidence suggesting the receptive-expressive gap may be harder to evaluate than previously thought because widely-used standardized tests may not offer comparable normed scores. Furthermore monolingual Spanish-speaking children tested in Mexico and monolingual English-speaking children in the US showed other, yet different statistically significant discrepancies between receptive and expressive scores. Results suggest comparisons across widely used standardized tests in attempts to assess a receptive-expressive gap are precarious.

  12. An investigation of the genetic toxicology of irradiated foodstuffs using short-term test systems

    International Nuclear Information System (INIS)

    Phillips, B.J.; Kranz, E.; Elias, P.S.

    1980-01-01

    As part of a programme of short-term tests used to detect possible genetic toxicity in irradiated foodstuffs, cultured Chinese hamster ovary cells were exposed to extracts and digests of irradiated and unirradiated dates, fish and chicken and subjected to tests for cytotoxicity, sister chromatid exchange induction and mutation to thioguanine resistance. The results showed no evidence of genetic toxicity induced in food by irradiation. The general applicability of cell culture tests to the detection of mutagens in food is discussed. (author)

  13. Recent progress on test evidence, standardization and design of protection for exterior openings

    Directory of Open Access Journals (Sweden)

    Strøm Ruth Astrid

    2016-01-01

    A number of different fire scenarios that elements in vented facades/constructions can be exposed to have been studied. New test standards have been developed for the last few years and are explained. Finally, this paper evaluate how different fire stop products perform in different fire scenarios and which test standards are applicable.

  14. Are Soft Short Tests Good Indicators of Internal Li-ion Cell Defects?

    Science.gov (United States)

    Jeevarajan, J.; Chung, J.-S.; Jung, K.; Park, J.

    2013-01-01

    The self discharge test at full state of charge, may not be a good one to detect subtle defects since the li-ion chemistry has the highest self discharge at full state of charge. One should characterize self discharge versus storage time for each cell manufacturer/design to differentiate between normal self discharge and that due to a subtle manufacturing defect. The various soft short test methods indicate that if this test is carried out at full discharge (0% SOC) with all capacity removed (by lowering the current load in a stepwise manner to the same end of discharge voltage), then the cells need to be placed in storage for more than 72 hours to get a good analysis on the presence of subtle defects since it takes more than 72 hours to achieve voltage stabilization. If the cells are to be charged up even to a small percentage (ex. 1%), 72 hours are sufficient to determine issues. However, the pass/fail criteria should be based on a valid OCV decline. Less than 10 mV voltage decline is not a good method to detect subtle defects. As mentioned in the first bullet, self discharge is a competing reaction when a charge is introduced and hence a characterization of the self discharge versus storage time is required to fully correlate voltage decline to a failure due to a subtle defect. Soft short test method cannot be relied on for defect detection because cells with and without voltage decline seemed to have similar defects and characteristics. Screening methods such as internal resistance and capacity as well as a 3-sigma range for OCV, mass and dimensions should be used to screen out outliers. A very critical aspect in the understanding of subtle defects is to carry out destructive analysis of cells from every lot to confirm the quality of production and screen all cells and batteries in a stringent manner to have a high quality set of flight cells. Self Discharge Test: Fully charged cells shall be placed in Open circuit stand for 72 hours (OCV measurement twice a

  15. Standard Test Method for Thermal Oxidative Resistance of Carbon Fibers

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1982-01-01

    1.1 This test method covers the apparatus and procedure for the determination of the weight loss of carbon fibers, exposed to ambient hot air, as a means of characterizing their oxidative resistance. 1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units which are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard information, see Section 8.

  16. Corporate Schooling Meets Corporate Media: Standards, Testing, and Technophilia

    Science.gov (United States)

    Saltman, Kenneth J.

    2016-01-01

    Educational publishing corporations and media corporations in the United States have been converging, especially through the promotion of standardization, testing, and for-profit educational technologies. Media and technology companies--including News Corp, Apple, and Microsoft--have significantly expanded their presence in public schools to sell…

  17. Two-photon collisions and short-distance tests of quantum chromodynamics

    International Nuclear Information System (INIS)

    Brodsky, S.J.

    1978-12-01

    The physics of two-photon collisions in e +- storage rings is reviewed with emphasis on the predictions of perturbative quantum chromodynamics for high transverse momentum reactions. It is noted that because of the remarkable scaling properties predicted by the theory, two-photon collisions may be proved one of the cleanest tests of the quantum chromodynamics picture of short distance hadron dynamics. In order to contrast these predictions for photon-induced reactions with those for incident hadrons, predictions from quantum chromodynamics for hadron structure functions and form factors at large momentum transfer are also discussed. 55 references

  18. Standard software for automated testing of infrared imagers, IRWindows, in practical applications

    Science.gov (United States)

    Irwin, Alan; Nicklin, Robert L.

    1998-08-01

    In the past, ad-hoc and manual testing of infrared images hasn't been a deterrent to the characterization of these systems due to the low volume of production and high ratio of skilled personnel to the quantity of units under test. However, with higher volume production, increasing numbers of development labs in emerging markets, and the push towards less expensive, faster development cycles, there is a strong need for standardized testing that is quickly configurable by test engineers, which can be run by less experienced test technicians, and which produce repeatable, accurate results. The IRWindowsTM system addresses these needs using a standard computing platform and existing automated IR test equipment. This paper looks at the general capabilities of the IRWindowsTM system, and then examines the specific results from its application in the PalmIR and Automotive IR production environments.

  19. Short communication

    African Journals Online (AJOL)

    abp

    2017-09-04

    Sep 4, 2017 ... Face-to-face interviews were conducted using a standardized ... Short communication. Open Access ... clinic during the time of the study and were invited to participate in the study. .... consume them. This is another ...

  20. Psychometric testing of the properties of the spiritual health scale short form.

    Science.gov (United States)

    Hsiao, Ya-Chu; Chiang, Yi-Chien; Lee, Hsiang-Chun; Han, Chin-Yen

    2013-11-01

    To further examine the psychometric properties of the spiritual health scale short form, including its reliability and validity. Spirituality is one of the main factors associated with good health outcomes. A reliable and valid instrument to measure spirituality is essential to identify the spiritual needs of an individual and to evaluate the effect of spiritual care. A cross-sectional study design was used. The study was conducted in six nursing schools in northern, central and southern Taiwan. The inclusion criterion for participants was nursing students with clinical practice experience. Initially, 1141 participants were recruited for the study, but 67 were absent and 48 did not complete the questionnaires. A total of 1026 participants were finally recruited, indicating a response rate of 89·9%. The psychometric testing of the spiritual health scale short form included construct validity with confirmatory factor analysis, known-group validity and internal consistency reliability. The results of the confirmatory factor analysis supported the five-factor model as an acceptable model fit. In the known-group validity, the results indicated that people who are in the category of primary religious affiliation have better spiritual health than people in the category of secondary religious affiliation and atheism. The result also indicated that the 24-item spiritual health scale short form achieved an acceptable internal consistency coefficient. The findings suggest that the spiritual health scale short form is a valid and reliable instrument for the appraisal of individual spiritual health. The spiritual health scale short form could provide useful information to guide clinical practice in assessing and managing people's spiritual health in Taiwan. © 2013 John Wiley & Sons Ltd.

  1. Standardization Efforts for Mechanical Testing and Design of Advanced Ceramic Materials and Components

    Science.gov (United States)

    Salem, Jonathan A.; Jenkins, Michael G.

    2003-01-01

    Advanced aerospace systems occasionally require the use of very brittle materials such as sapphire and ultra-high temperature ceramics. Although great progress has been made in the development of methods and standards for machining, testing and design of component from these materials, additional development and dissemination of standard practices is needed. ASTM Committee C28 on Advanced Ceramics and ISO TC 206 have taken a lead role in the standardization of testing for ceramics, and recent efforts and needs in standards development by Committee C28 on Advanced Ceramics will be summarized. In some cases, the engineers, etc. involved are unaware of the latest developments, and traditional approaches applicable to other material systems are applied. Two examples of flight hardware failures that might have been prevented via education and standardization will be presented.

  2. Standard test method for electrochemical critical pitting temperature testing of stainless steels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers a procedure for the evaluation of the resistance of stainless steel and related alloys to pitting corrosion based on the concept of the determination of a potential independent critical pitting temperature (CPT). 1.2 This test methods applies to wrought and cast products including but not restricted to plate, sheet, tubing, bar, forgings, and welds, (see Note 1). Note 1—Examples of CPT measurements on sheet, plate, tubing, and welded specimens for various stainless steels can be found in Ref (1). See the research reports (Section 14). 1.3 The standard parameters recommended in this test method are suitable for characterizing the CPT of austenitic stainless steels and other related alloys with a corrosion resistance ranging from that corresponding to solution annealed UNS S31600 (Type 316 stainless steel) to solution annealed UNS S31254 (6 % Mo stainless steel). 1.4 This test method may be extended to stainless steels and other alloys related to stainless steel that have a CPT...

  3. Standard Test Method for Solar Transmittance (Terrestrial) of Sheet Materials Using Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1986-01-01

    1.1 This test method covers the measurement of solar transmittance (terrestrial) of materials in sheet form by using a pyranometer, an enclosure, and the sun as the energy source. 1.2 This test method also allows measurement of solar transmittance at angles other than normal incidence. 1.3 This test method is applicable to sheet materials that are transparent, translucent, textured, or patterned. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. Towards reporting standards for neuropsychological study results: A proposal to minimize communication errors with standardized qualitative descriptors for normalized test scores.

    Science.gov (United States)

    Schoenberg, Mike R; Rum, Ruba S

    2017-11-01

    Rapid, clear and efficient communication of neuropsychological results is essential to benefit patient care. Errors in communication are a lead cause of medical errors; nevertheless, there remains a lack of consistency in how neuropsychological scores are communicated. A major limitation in the communication of neuropsychological results is the inconsistent use of qualitative descriptors for standardized test scores and the use of vague terminology. PubMed search from 1 Jan 2007 to 1 Aug 2016 to identify guidelines or consensus statements for the description and reporting of qualitative terms to communicate neuropsychological test scores was conducted. The review found the use of confusing and overlapping terms to describe various ranges of percentile standardized test scores. In response, we propose a simplified set of qualitative descriptors for normalized test scores (Q-Simple) as a means to reduce errors in communicating test results. The Q-Simple qualitative terms are: 'very superior', 'superior', 'high average', 'average', 'low average', 'borderline' and 'abnormal/impaired'. A case example illustrates the proposed Q-Simple qualitative classification system to communicate neuropsychological results for neurosurgical planning. The Q-Simple qualitative descriptor system is aimed as a means to improve and standardize communication of standardized neuropsychological test scores. Research are needed to further evaluate neuropsychological communication errors. Conveying the clinical implications of neuropsychological results in a manner that minimizes risk for communication errors is a quintessential component of evidence-based practice. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Standard Test Method for Solar Photometric Transmittance of Sheet Materials Using Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1996-01-01

    1.1 This test method covers the measurement of solar photometric transmittance of materials in sheet form. Solar photometric transmittance is measured using a photometer (illuminance meter) in an enclosure with the sun and sky as the source of radiation. The enclosure and method of test is specified in Test Method E 1175 (or Test Method E 1084). 1.2 The purpose of this test method is to specify a photometric sensor to be used with the procedure for measuring the solar photometric transmittance of sheet materials containing inhomogeneities in their optical properties. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  6. A primary standard for the calibration of sniffer test leak devices

    Science.gov (United States)

    Jousten, Karl; Becker, Ute

    2009-10-01

    Test leaks with a gas flow to atmospheric pressure are often called sniffer test leaks. They are used to calibrate leak detectors for sniffing applications. Sniffer test leaks need calibration against a standard. A primary standard for the calibration of sniffer test leaks with relatively low measurement uncertainties is described. It is assured that the measurement result is traceable to the relevant SI units and that there is a well-known and complete measurement uncertainty budget. The measurement range of the system is from 4 × 10-11 mol s-1 (corresponding to 10-4 Pa l s-1 at 23 °C) to 4 × 10-9 mol s-1 (10-2 Pa l s-1 at 23 °C), which is the most often needed range in industry of around 1 g loss per year of the cooling agent R134a. The temperature where the calibration can be carried out may vary from 18 °C to 30 °C. The flow rate of any test gas not condensing in this temperature range can be measured.

  7. Relationship between Short Term Memory and Cardiopulmonary Fitness of Administrative Officers at Universitas Padjadjaran

    Directory of Open Access Journals (Sweden)

    Iswaran Ampalakan

    2016-03-01

    Full Text Available Background: The work of administrative officers depends a lot on their capability in memorizing. Increased fitness is strongly associated with a better memory. This study was conducted to determine the relationship between cardiopulmonary fitness and short term memory. Methods: This analytical cross sectional study was carried out from August to September 2014. Subjects from administrative offices within Universitas Padjadjaran were chosen by simple random sampling. 101 individuals were selected, comprising of 68 males and 33 females. Data were obtained through Digit Span Test for short term memory and the cardiopulmonary fitness was measured using Harvard Step Test. The VO2 Max obtained was correlated with the Digit Span Test score. Results: The mean for cardiopulmonary fitness of males was found to be 36.1, with standard deviation 8.63, whereas mean cardiopulmonary fitness for females was found to be 32.94, with standard deviation 7.5. For correlation analysis, the result of Spearman’s rank analysis from the study showed that the p-value is 0.00. Comparing to the significance level α=5%, the p value is worth less, thus the null hypothesis, Ho is rejected. Therefore, it could be concluded that there was a relationship between cardiopulmonary fitness and short term memory of male and female administrative officers at Universitas Padjadjaran. Conclusions: There is a relationship between cardiopulmonary fitness and short term memory of male and female administrative officers at Universitas Padjadjaran.

  8. Standard test method for exfoliation corrosion susceptibility in 2XXX and 7XXX Series Aluminum Alloys (EXCO Test)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method covers a procedure for constant immersion exfoliation corrosion (EXCO) testing of high-strength 2XXX and 7XXX series aluminum alloys. Note 1—This test method was originally developed for research and development purposes; however, it is referenced, in specific material specifications, as applicable for evaluating production material (refer to Section 14 on Precision and Bias). 1.2 This test method applies to all wrought products such as sheet, plate, extrusions, and forgings produced from conventional ingot metallurgy process. 1.3 This test method can be used with any form of specimen or part that can be immersed in the test solution. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  9. Standard test method for measurement of oxidation-reduction potential (ORP) of soil

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers a procedure and related test equipment for measuring oxidation-reduction potential (ORP) of soil samples removed from the ground. 1.2 The procedure in Section 9 is appropriate for field and laboratory measurements. 1.3 Accurate measurement of oxidation-reduction potential aids in the analysis of soil corrosivity and its impact on buried metallic structure corrosion rates. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Ethnic identity, school connectedness, and achievement in standardized tests among Mexican-origin youth.

    Science.gov (United States)

    Santos, Carlos E; Collins, Mary Ann

    2016-07-01

    The aim of this study was to investigate the association between school connectedness and performance in standardized test scores and whether this association was moderated by ethnic private regard. The study combines self-report data with school district reported data on standardized test scores in reading and math and free and reduced lunch status. Participants included 436 Mexican-origin youth attending a middle school in a southwestern U.S. state. Participants were on average 12.34 years of age (SD = .95) and 51.8% female and 48.2% male. After controlling for age, gender, free and reduced lunch status, and generational status, school connectedness and ethnic private regard were both positive predictors of standardized test scores in reading and math. Results also revealed a significant interaction between school connectedness and ethnic private regard in predicting standardized test scores in reading, such that participants who were low on ethnic private regard and low on school connectedness reported lower levels of achievement compared to participants who were low on ethnic private regard but high on school connectedness. At high levels of ethnic private regard, high or low levels of school connectedness were not associated with higher or lower standardized test scores in reading. The findings in this study provide support for the protective role that ethnic private regard plays in the educational experiences of Mexican-origin youth and highlights how the local school context may play a role in shaping this finding. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  11. Revision to dedicated short range communication roadside equipment specification - RSU 4.1.Bench Test Plan.

    Science.gov (United States)

    2017-04-28

    The document describes the overall process for evaluating Dedicated Short Range Communication (DSRC) Roadside Units (RSU) against USDOT RSU Specification 4.1 in preparation for field evaluation. The Test Cases contained in this document only evaluate...

  12. Standard Test Method for Bond Strength of Ceramic Tile to Portland Cement Paste

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of the ability of glazed ceramic wall tile, ceramic mosaic tile, quarry tile, and pavers to be bonded to portland cement paste. This test method includes both face-mounted and back-mounted tile. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  13. Non-prescription medicines: a process for standards development and testing in community pharmacy.

    Science.gov (United States)

    Benrimoj, Shalom Charlie I; Gilbert, Andrew; Quintrell, Neil; Neto, Abilio C de Almeida

    2007-08-01

    The objective of the study was to develop and test standards of practice for handling non-prescription medicines. In consultation with pharmacy registering authorities, key professional and consumer groups and selected community pharmacists, standards of practice were developed in the areas of Resource Management; Professional Practice; Pharmacy Design and Environment; and Rights and Needs of Customers. These standards defined and described minimum professional activities required in the provision of non-prescription medicines at a consistent and measurable level of practice. Seven standards were described and further defined by 20 criteria, including practice indicators. The Standards were tested in 40 community pharmacies in two States and after further adaptation, endorsed by all Australian pharmacy registering authorities and major Australian pharmacy and consumer organisations. The consultation process effectively engaged practicing pharmacists in developing standards to enable community pharmacists meet their legislative and professional responsibilities. Community pharmacies were audited against a set of standards of practice for handling non-prescription medicines developed in this project. Pharmacies were audited on the Standards at baseline, mid-intervention and post-intervention. Behavior of community pharmacists and their staff in relation to these standards was measured by conducting pseudo-patron visits to participating pharmacies. The testing process demonstrated a significant improvement in the quality of service delivered by staff in community pharmacies in the management of requests involving non-prescription medicines. The use of pseudo-patron visits, as a training tool with immediate feedback, was an acceptable and effective method of achieving changes in practice. Feedback from staff in the pharmacies regarding the pseudo-patron visits was very positive. Results demonstrated the methodology employed was effective in increasing overall

  14. Standard test method for radiochemical determination of plutonium in Soil by alpha spectroscopy

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of plutonium in soils at levels of detection dependent on count time, sample size, detector, background, and tracer yield. This test method describes one acceptable approach to the determination of plutonium in soil. 1.2 This test method is designed for 10 g of soil, previously collected and treated as described in Practices C998 and C999, but sample sizes up to 50 g may be analyzed by this test method. This test method may not be able to completely dissolve all forms of plutonium in the soil matrix. 1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 9.

  15. Standard Test Method for Preparing Aircraft Cleaning Compounds, Liquid Type, Water Base, for Storage Stability Testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of the stability in storage, of liquid, water-base chemical cleaning compounds, used to clean the exterior surfaces of aircraft. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  16. X-ray testing for short-time dynamic applications; Roentgenuntersuchungen fuer kurzzeitdynamische Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Kurfiss, Malte; Moser, Stefan; Popko, Gregor; Nau, Siegfried [Fraunhofer-Institut fuer Kurzzeitdynamik, Efringen-Kirchen (Germany). Ernst-Mach-Inst. (EMI)

    2017-08-01

    For nondestructive testing purposes new challenges are short-time dynamic processes. The application of x-ray flash tubes and modern high-speed cameras allows the observation of the opening of air-bags or the energy absorption of compressed tubes as occurring during a vehicle crash. Special algorithms designed for computerized tomography analyses allow the 3D reconstruction at individual time points of the dynamic process. Possibilities and limitations of the actual techniques are discussed.

  17. Fundamental tests and measures of the structure of matter at short distances

    International Nuclear Information System (INIS)

    Brodsky, S.J.

    1981-07-01

    Recent progress in gauge field theories has led to a new perspective on the structure of matter and basic interactions at short distances. It is clear that at very high energies quantum electrodynamics, together with the weak and strong interactions, are part of a unified theory with new fundamental constants, new symmetries, and new conservation laws. A non-technical introduction to these topics is given, with emphasis on fundamental tests and measurements. 21 references

  18. Standard practice for torque calibration of testing machines and devices

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This practice covers procedures and requirements for the calibration of torque for static and quasi-static torque capable testing machines or devices. These may, or may not, have torque indicating systems and include those devices used for the calibration of hand torque tools. Testing machines may be calibrated by one of the three following methods or combination thereof: 1.1.1 Use of standard weights and lever arms. 1.1.2 Use of elastic torque measuring devices. 1.1.3 Use of elastic force measuring devices and lever arms. 1.1.4 Any of the methods require a specific uncertainty of measurement and a traceability derived from national standards of mass and length. 1.2 The procedures of 1.1.1, 1.1.2, and 1.1.3 apply to the calibration of the torque-indicating systems associated with the testing machine, such as a scale, dial, marked or unmarked recorder chart, digital display, etc. In all cases the buyer/owner/user must designate the torque-indicating system(s) to be calibrated and included in the repor...

  19. Standard Test Method for Half-Cell Potentials of Uncoated Reinforcing Steel in Concrete

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the estimation of the electrical corrosion potential of uncoated reinforcing steel in field and laboratory concrete, for the purpose of determining the corrosion activity of the reinforcing steel. 1.2 This test method is limited by electrical circuitry. Concrete surface in building interiors and desert environments lose sufficient moisture so that the concrete resistivity becomes so high that special testing techniques not covered in this test method may be required (see 5.1.4.1). Concrete surfaces that are coated or treated with sealers may not provide an acceptable electrical circuit. The basic configuration of the electrical circuit is shown in Fig. 1. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It ...

  20. Standard Test Method for Gravimetric Determination of Nonvolatile Residue from Cleanroom Gloves

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of solvent extractable nonvolatile residue (NVR) from gloves used in cleanrooms where spacecraft are assembled, cleaned, or tested. 1.2 The NVR of interest is that which can be extracted from gloves using a specified solvent that has been selected for its extracting qualities, or because it is representative of solvents used in the particular facility. Alternative solvents may be used, but since their use may result in different values being generated, they must be identified in the procedure data sheet. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  1. Standard Test Method for Gravimetric Determination of Nonvolatile Residue From Cleanroom Wipers

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers the determination of solvent extractable nonvolatile residue (NVR) from wipers used in assembly, cleaning, or testing of spacecraft, but not from those used for analytical surface sampling of hardware. 1.2 The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard. 1.3 The NVR of interest is that which can be extracted from cleanroom wipers using a specified solvent that has been selected for its extractive qualities. Alternative solvents may be selected, but since their use may result in different values being generated, they must be identified in the procedure data sheet. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. Development of ASTM Standard for SiC-SiC Joint Testing Final Scientific/Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Jacobsen, George [General Atomics, San Diego, CA (United States); Back, Christina [General Atomics, San Diego, CA (United States)

    2015-10-30

    As the nuclear industry moves to advanced ceramic based materials for cladding and core structural materials for a variety of advanced reactors, new standards and test methods are required for material development and licensing purposes. For example, General Atomics (GA) is actively developing silicon carbide (SiC) based composite cladding (SiC-SiC) for its Energy Multiplier Module (EM2), a high efficiency gas cooled fast reactor. Through DOE funding via the advanced reactor concept program, GA developed a new test method for the nominal joint strength of an endplug sealed to advanced ceramic tubes, Fig. 1-1, at ambient and elevated temperatures called the endplug pushout (EPPO) test. This test utilizes widely available universal mechanical testers coupled with clam shell heaters, and specimen size is relatively small, making it a viable post irradiation test method. The culmination of this effort was a draft of an ASTM test standard that will be submitted for approval to the ASTM C28 ceramic committee. Once the standard has been vetted by the ceramics test community, an industry wide standard methodology to test joined tubular ceramic components will be available for the entire nuclear materials community.

  3. International standardization of instruments for neutron irradiation tests

    International Nuclear Information System (INIS)

    Tanimoto, Masataka; Shibata, Akira; Nakamura, Jinichi; Tsuchiya, Kunihiko; Cho, M.; Lee, C.; Park, S.; Choo, K.

    2012-01-01

    The JMTR in JAEA and HANARO in KAERI are the foremost testing/research reactors in the world and these are expected to contribute to many nuclear fields. As a part of instrument development in irradiation field, information exchange of instruments started from 2010 under the cooperation agreements between KAERI and JAEA. The instruments developed in JMTR and HANARO are introduced and cooperation experiments as future plan are discussed for international standardization. (author)

  4. Selecting short-statured children needing growth hormone testing: Derivation and validation of a clinical decision rule

    Directory of Open Access Journals (Sweden)

    Bréart Gérard

    2008-07-01

    Full Text Available Abstract Background Numerous short-statured children are evaluated for growth hormone (GH deficiency (GHD. In most patients, GH provocative tests are normal and are thus in retrospect unnecessary. Methods A retrospective cohort study was conducted to identify predictors of growth hormone (GH deficiency (GHD in children seen for short stature, and to construct a very sensitive and fairly specific predictive tool to avoid unnecessary GH provocative tests. GHD was defined by the presence of 2 GH concentration peaks Results The initial study included 167 patients, 36 (22% of whom had GHD, including 5 (3% with certain GHD. Independent predictors of GHD were: growth rate Conclusion We have derived and performed an internal validation of a highly sensitive decision rule that could safely help to avoid more than 2/3 of the unnecessary GH tests. External validation of this rule is needed before any application.

  5. Within-day variability on short and long walking tests in persons with multiple sclerosis.

    Science.gov (United States)

    Feys, Peter; Bibby, Bo; Romberg, Anders; Santoyo, Carme; Gebara, Benoit; de Noordhout, Benoit Maertens; Knuts, Kathy; Bethoux, Francois; Skjerbæk, Anders; Jensen, Ellen; Baert, Ilse; Vaney, Claude; de Groot, Vincent; Dalgas, Ulrik

    2014-03-15

    To compare within-day variability of short (10 m walking test at usual and fastest speed; 10MWT) and long (2 and 6-minute walking test; 2MWT/6MWT) tests in persons with multiple sclerosis. Observational study. MS rehabilitation and research centers in Europe and US within RIMS (European network for best practice and research in MS rehabilitation). Ambulatory persons with MS (Expanded Disability Status Scale 0-6.5). Subjects of different centers performed walking tests at 3 time points during a single day. 10MWT, 2MWT and 6MWT at fastest speed and 10MWT at usual speed. Ninety-five percent limits of agreement were computed using a random effects model with individual pwMS as random effect. Following this model, retest scores are with 95% certainty within these limits of baseline scores. In 102 subjects, within-day variability was constant in absolute units for the 10MWT, 2MWT and 6MWT at fastest speed (+/-0.26, 0.16 and 0.15m/s respectively, corresponding to +/-19.2m and +/-54 m for the 2MWT and 6MWT) independent on the severity of ambulatory dysfunction. This implies a greater relative variability with increasing disability level, often above 20% depending on the applied test. The relative within-day variability of the 10MWT at usual speed was +/-31% independent of ambulatory function. Absolute values of within-day variability on walking tests at fastest speed were independent of disability level and greater with short compared to long walking tests. Relative within-day variability remained overall constant when measured at usual speed. Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.

  6. Precision tests of quantum chromodynamics and the standard model

    International Nuclear Information System (INIS)

    Brodsky, S.J.; Lu, H.J.

    1995-06-01

    The authors discuss three topics relevant to testing the Standard Model to high precision: commensurate scale relations, which relate observables to each other in perturbation theory without renormalization scale or scheme ambiguity, the relationship of compositeness to anomalous moments, and new methods for measuring the anomalous magnetic and quadrupole moments of the W and Z

  7. Standardized Testing and School Segregation: Like Tinder for Fire?

    Science.gov (United States)

    Knoester, Matthew; Au, Wayne

    2017-01-01

    Recent research suggests that high-stakes standardized testing has played a negative role in the segregation of children by race and class in schools. In this article we review research on the overall effects of segregation, the positive and negative aspects of how desegregation plans were carried out following the 1954 Supreme Court decision…

  8. Survey report for fiscal 1999. Reference book for standard heat calculations in high-performance industrial furnace introduction field test project; 1999 nendo koseino kogyoro donyu field test jigyo chosa hokokusho. Hyojun netsu keisanshiki kijunsho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    With an objective to verify in a short time the heat recovery capability being the evaluation parameter for the technologies to develop the high-performance industrial furnace, a standard calculation book will be prepared, which standardizes the data collection methods and heat calculation methods, and is used as the standard data sheets and bases. Evaluations and analyses will be given on business types, furnace constructions, thermal technologies, and functions in the research items adopted in the field test project. The results will be used to recognize the business entities engaged in the project in the next fiscal year, furnace types and sizes, establish the industrial furnace subjected to researches in the next fiscal year, and proliferate and expand the related business entities. Standard data sheets will be prepared on seven kinds of furnaces, heating furnaces (continuous and batch types), ladles, heat treatment furnaces (continuous and batch types), gas treatment furnaces, and melting furnaces. The standard data sheets will cover the following items: evaluation parameters (energy saving rate, thermal efficiency, and waste heat recovery rate), calculating conditions to be the base for the evaluation parameters, a heat production book to be the base for calculating the heat unit requirement, and a standard calculation book to be the base for the heat production table. The standard data sheets (including the standard calculation book) and floppy disks are submitted. (NEDO)

  9. Seminar on standards, standardization, quality control and interlaboratory test programmes

    Energy Technology Data Exchange (ETDEWEB)

    de Bievre, P. [Central Bureau for Nuclear Measurements, Geel (Belgium)

    1978-12-15

    The author gives a resume on the proper use of standards and standardization of measurement procedures. Results of measurements obtained on the same instrument and on the same series of standards of different isotopic compositions are displayed.

  10. Standard Test Method for Measuring Dose for Use in Linear Accelerator Pulsed Radiation Effects Tests

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers a calorimetric measurement of the total dose delivered in a single pulse of electrons from an electron linear accelerator or a flash X-ray machine (FXR, e-beam mode) used as an ionizing source in radiation-effects testing. The test method is designed for use with pulses of electrons in the energy range from 10 to 50 MeV and is only valid for cases in which both the calorimeter and the test specimen to be irradiated are“thin” compared to the range of these electrons in the materials of which they are constructed. 1.2 The procedure described can be used in those cases in which (1) the dose delivered in a single pulse is 5 Gy (matl) (500 rd (matl)) or greater, or (2) multiple pulses of a lower dose can be delivered in a short time compared to the thermal time constant of the calorimeter. Matl refers to the material of the calorimeter. The minimum dose per pulse that can be acceptably monitored depends on the variables of the particular test, including pulse rate, pulse uniformity...

  11. The status of ANSI N13.11 - The dosimeter performance test standard

    International Nuclear Information System (INIS)

    Sims, C.S.

    1991-01-01

    The standard designated ANSI N13.11 was issued in 1983 and is the basis for the dosimeter performance test associated with the National Voluntary Laboratory Accreditation Program (NVLAP). The standard is important because the Nuclear Regulatory Commission requires that all licensees use personnel dosimeters processed by NVLAP-accredited processors. The standard has undergone review and modifications have been recommended. Historical information concerning the development and utilization of the present standard, ANSI N13.11-1983, is presented. Details associated with the review of the standard (e.g., policy, group selection) are then given. Finally, the modifications recommended by the review group are discussed

  12. NREL/NASA Internal Short-Circuit Instigator in Lithium Ion Cells

    Energy Technology Data Exchange (ETDEWEB)

    Keyser, Matthew; Long, Dirk; Pesaran, Ahmad; Darcy, Eric; Shoesmith, Mark; McCarthy, Ben

    2015-10-11

    Lithium-ion cells provide the highest specific energy (>280 Wh/kg) and energy density (>600 Wh/L) rechargeable battery building block to date with the longest life. Electrode/electrolyte thermal instability and flammability of the electrolyte of Li-ion cells make them prone to catastrophic thermal runaway under some rare internal short circuit conditions. Despite extensive QC/QA, standardized industry safety testing, and over 18 years of manufacturing experience, major recalls have taken place and incidents still occur. Many safety incidents that take place in the field originate due to an internal short that was not detectable or predictable at the point of manufacture. The Internal Short-Circuit Instigator can be used to study types of separators, non-flammable electrolytes, electrolyte additives, fusible tabs, propagation studies, and gas generation within a cell.

  13. Engineering scale tests of mechanical disassembly and short stroke shearing systems for FBR fuel assembly

    International Nuclear Information System (INIS)

    Higuchi, Hidetoshi; Kitagaki, Toru; Koizumi, Kenji; Hirano, Hiroyasu; Takeuchi, Masayuki; Washiya, Tadahiro; Kawabe, Yukinari; Kobayashi, Tsuguyuki

    2011-01-01

    Japan Atomic Energy Agency (JAEA) and The Japan Atomic Power Company (JAPC) have been developing an advanced head-end process based on mechanical disassembly and short stroke shearing systems as a part of Fast Reactor Cycle Technology Development (FaCT). Fuel pins for a fast reactor are installed within a hexagonal shaped wrapper tube made of stainless steel. In order to reprocess the fast reactor fuel pins, they must be removed from the wrapper tube and transported to the shearing system without failure. In addition, the advanced aqueous reprocessing process, called 'NEXT' (New Extraction System for TRU Recovery) process requires a solution of the spent fuel with relatively high concentration (500g/L). JAEA and JAPC have developed the mechanical disassembly and the short stroke shearing technology which is expected to make fragmented fuel to satisfy these requirements. This paper reports the results of engineering scale tests on the mechanical disassembly and short stroke shearing systems. These tests were carried out with simulated FBR fuel assembly and removed pins. The mechanical cutting method has been developed to avoid fuel pin failure during disassembly operation. The cutting process is divided into two modes, so called 'slit-cut' for cutting the wrapper tube and 'crop-cut' for the end plug region of the fuel pin bundle. In the slit-cut mode, the depth of cutting was automatically controlled based on the calculated wastage of the cutting tool and deformation of the wrapper tube which had been measured before the cutting. This procedure was confirmed to minimize the fuel pin failure which was hard to prevent in the case of laser cutting. The cutting speed was also controlled automatically by the electric current of the cutting motor to lower the load of the cutting tool. The removed fuel pins were transported to the shearing machine, whose fuel shearing magazine width was set to be narrow to realize the suitable configuration for the short stroke shearing

  14. Standards for Radiation Effects Testing: Ensuring Scientific Rigor in the Face of Budget Realities and Modern Device Challenges

    Science.gov (United States)

    Lauenstein, J M.

    2015-01-01

    An overview is presented of the space radiation environment and its effects on electrical, electronic, and electromechanical parts. Relevant test standards and guidelines are listed. Test standards and guidelines are necessary to ensure best practices, minimize and bound systematic and random errors, and to ensure comparable results from different testers and vendors. Test standards are by their nature static but exist in a dynamic environment of advancing technology and radiation effects research. New technologies, failure mechanisms, and advancement in our understanding of known failure mechanisms drive the revision or development of test standards. Changes to standards must be weighed against their impact on cost and existing part qualifications. There must be consensus on new best practices. The complexity of some new technologies exceeds the scope of existing test standards and may require development of a guideline specific to the technology. Examples are given to illuminate the value and limitations of key radiation test standards as well as the challenges in keeping these standards up to date.

  15. Overburden Stress Normalization and Rod Length Corrections for the Standard Penetration Test (SPT)

    OpenAIRE

    Deger, Tonguc Tolga

    2014-01-01

    The Standard Penetration Test (SPT) has been a staple of geotechnical engineering practice for more than 70 years. Empirical correlations based on in situ SPT data provide an important basis for assessment of a broad range of engineering parameters, and for empirically based analysis and design methods spanning a significant number of areas of geotechnical practice. Despite this longstanding record of usage, the test itself is relatively poorly standardized with regard to the allowable variab...

  16. Practical issues for testing thin film PV modules at standard test conditions.

    OpenAIRE

    Marín González, Omar; Raga Arroyo, Manuela Pilar; Alonso Garcia, M. Carmen; Muñoz-García, Miguel Angel

    2013-01-01

    Thin film photovoltaic (TF) modules have gained importance in the photovoltaic (PV) market. New PV plants increasingly use TF technologies. In order to have a reliable sample of a PV module population, a huge number of modules must be measured. There is a big variety of materials used in TF technology. Some of these modules are made of amorphous or microcrystalline silicon. Other are made of CIS or CdTe. Not all these materials respond the same under standard test conditions (STC) of power...

  17. Standard Test Method for Resin Flow of Carbon Fiber-Epoxy Prepreg

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers the determination of the amount of resin flow that will take place from prepreg tape or sheet under given conditions of temperature and pressure. 1.2 The values stated in SI units are to be regarded as standard. The values in parentheses are for reference only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  18. Standard Test Methods for Insulation Integrity and Ground Path Continuity of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 These test methods cover procedures for (1) testing for current leakage between the electrical circuit of a photovoltaic module and its external components while a user-specified voltage is applied and (2) for testing for possible module insulation breakdown (dielectric voltage withstand test). 1.2 A procedure is described for measuring the insulation resistance between the electrical circuit of a photovoltaic module and its external components (insulation resistance test). 1.3 A procedure is provided for verifying that electrical continuity exists between the exposed external conductive surfaces of the module, such as the frame, structural members, or edge closures, and its grounding point (ground path continuity test). 1.4 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method. 1.5 There is no similar or equivalent ISO standard. This standard does not purport to address all of the safety concerns, if a...

  19. Problems in Standardization of Orthodontic Shear Bond Strength Tests; A Brief Review

    Directory of Open Access Journals (Sweden)

    M.S. A. Akhoundi

    2005-03-01

    Full Text Available Bonding brackets to the enamel surface has gained much popularity today. New adhesive systems have been introduced and marketed and a considerable increase in research regarding bond strength has been published. A considerable amount of these studies deal with shear bond strength of adhesives designed for orthodontic purpose.Previous studies have used variety of test designs. This diversity in test design is due to the fact that there is no standard method for evaluating shear bond strength in orthodontics. Therefore comparison of data obtained from different study is almost impossible.This article tries to briefly discuss the developments occurred in the process of shear bond strength measurement of orthodontic adhesives with an emphasis on the type of test set up and load application.Although the test designs for measuring shear bond strength in orthodontics are still far from ideal, attempts must be made to standardize these tests especially in order to makecomparison of different data easier. It is recommended that test designs be set up in such a manner that better matches with the purpose of the study.

  20. Standard test method for damage to contacting solid surfaces under fretting conditions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the studying or ranking the susceptibility of candidate materials to fretting corrosion or fretting wear for the purposes of material selection for applications where fretting corrosion or fretting wear can limit serviceability. 1.2 This test method uses a tribological bench test apparatus with a mechanism or device that will produce the necessary relative motion between a contacting hemispherical rider and a flat counterface. The rider is pressed against the flat counterface with a loading mass. The test method is intended for use in room temperature air, but future editions could include fretting in the presence of lubricants or other environments. 1.3 The purpose of this test method is to rub two solid surfaces together under controlled fretting conditions and to quantify the damage to both surfaces in units of volume loss for the test method. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5...

  1. Corporate Testing: Standards, Profits, and the Demise of the Public Sphere

    Science.gov (United States)

    Leistyna, Pepi

    2007-01-01

    This article examines the standardized high-stakes testing in the wake of the No Child Left Behind (NCLB) movement. It focuses on the political economy of the testing industry; that is, a look into the ownership, intent, and regulation of the private forces that produce, provide materials, prep sessions, and tutorials for and evaluate, report on,…

  2. Standard Specification for Solar Simulation for Terrestrial Photovoltaic Testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This specification provides means for classifying solar simulators intended for indoor testing of photovoltaic devices (solar cells or modules), according to their spectral match to a reference spectral irradiance, non-uniformity of spatial irradiance, and temporal instability of irradiance. 1.2 Testing of photovoltaic devices may require the use of solar simulators. Test Methods that require specific classification of simulators as defined in this specification include Test Methods E948, E1036, and E1362. 1.3 This standard is applicable to both pulsed and steady state simulators and includes recommended test requirements used for classifying such simulators. 1.4 A solar simulator usually consists of three major components: (1) light source(s) and associated power supply; (2) any optics and filters required to modify the output beam to meet the classification requirements in Section 4; and (3) the necessary controls to operate the simulator, adjust irradiance, etc. 1.5 A light source that does not mee...

  3. Standard testing procedures for optical fiber and unshielded twisted pair at Sandia National Laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Adams, R.L.

    1993-11-01

    This document will establish a working standard for testing optical fiber and unshielded twisted pair cables included in the Lab-wide telecommunications cabling system. The purpose of these standard testing procedures is to deliver to all Sandians a reliable, low-maintenance, state-of-the-art, ubiquitous telecommunications cabling infrastructure capable of satisfying all current and future telecommunication needs.

  4. Standard test method for radiochemical determination of uranium isotopes in urine by alpha spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method is applicable to the determination of uranium in urine at levels of detection dependent on sample size, count time, detector background, and tracer yield. It is designed as a screening tool for detection of possible exposure of occupational workers. 1.2 This test method is designed for 50 mL of urine. This test method does not address the sampling protocol or sample preservation methods associated with its use. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Testing for structural change in the presence of long memory

    OpenAIRE

    Krämer, Walter; Sibbertsen, Philipp

    2000-01-01

    We derive the limiting null distributions of the standard and OLS-based CUSUM-tests for structural change of the coefficients of a linear regression model in the context of long memory disturbances. We show that both tests behave fundamentally different in a long memory environment, as compared to short memory, and that long memory is easily mistaken for structural change when standard critical values are employed.

  6. 78 FR 70324 - Thy Hydrostatic Testing Provision of the Portable Fire Extinguishers Standard; Extension of the...

    Science.gov (United States)

    2013-11-25

    ... Hydrostatic Testing Provision of the Portable Fire Extinguishers Standard; Extension of the Office of...) approval of the information collection requirements contained in the Hydrostatic Testing provision of the... Hydrostatic Testing Provision of the Portable Fire Extinguishers Standard are necessary to reduce workers...

  7. Testing the standard model with precision calculations of semileptonic B-decays

    International Nuclear Information System (INIS)

    Turczyk, Sascha S.

    2011-01-01

    Measurements in the flavour sector are very important to test the Standard Model, since most of the free parameters are related to flavour physics. We are discussing semileptonic B-meson decays, from which an important parameter, vertical stroke V cb vertical stroke, is extracted. First we discuss higher-order non-perturbative corrections in inclusive semileptonic decays of B mesons. We identify the relevant hadronic matrix elements up to 1/m 5 b and estimate them using an approximation scheme. Within this approach the e ects on the integrated rate and on kinematic moments are estimated. Similar estimates are presented for B → X s + γ decays. Furthermore we investigate the role of so-called ''intrinsic-charm'' operators in this decay, which appear first at order 1/m 3 b in the heavy-quark expansion. We show by explicit calculation that - at scales μ ≤ m c - the contributions from ''intrinsic-charm'' effects can be absorbed into short-distance coefficient functions multiplying, for instance, the Darwin term. Then, the only remnant of ''intrinsic charm'' are logarithms of the form ln(m 2 c /m 2 b ), which can be resummed by using renormalization-group techniques. As long as the dynamics at the charm quark scale is perturbative, α s (m c ) 3 b . However, ''intrinsic charm'' leads at the next order to terms with inverse powers of the charm mass: 1/m 3 b x 1/m 2 c . Parametrically they complement the estimate of the potential impact of 1/m 4 b contributions, which we will explore. In this context, we draw semiquantitative conclusions for the expected scale of weak annihilation in semileptonic B decays, both for its valence and non-valence components. The last part is dedicated to a complementary measurement of vertical stroke V cb vertical stroke from exclusive B → D (*) l anti ν l . Since this determination shows a slight tension with respect to the inclusive one, we investigate wether a non standard model contribution may distort the extraction. (orig.)

  8. 45 CFR 170.455 - Testing and certification to newer versions of certain standards.

    Science.gov (United States)

    2010-10-01

    ... INFORMATION TECHNOLOGY HEALTH INFORMATION TECHNOLOGY STANDARDS, IMPLEMENTATION SPECIFICATIONS, AND CERTIFICATION CRITERIA AND CERTIFICATION PROGRAMS FOR HEALTH INFORMATION TECHNOLOGY Temporary Certification Program for HIT § 170.455 Testing and certification to newer versions of certain standards. (a) ONC-ATCBs...

  9. Standard Test Method for Measuring Heat Flux Using a Water-Cooled Calorimeter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the measurement of a steady heat flux to a given water-cooled surface by means of a system energy balance. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Psychometric evaluation of the Chinese version of short-form Test of Functional Health Literacy in Adolescents.

    Science.gov (United States)

    Chang, Li-Chun; Hsieh, Pei-Lin; Liu, Chieh-Hsing

    2012-09-01

    The purpose of this study is to develop and evaluate the psychometric properties of the Chinese version of short-form Test of Functional Health Literacy in Adolescents. Assessing health literacy is vital to design health education programme; however, there are no measurement tools exist for use specifically in Chinese adolescents. A non-experimental design was used to test the psychometric properties of the Test of Functional Health Literacy in Adolescents. The short-form Test of Functional Health Literacy in Adolescents was translated and back translated into a Chinese language version. Thirty high school students were recruited to validate the scenario of Test of Functional Health Literacy in Adolescents. Based on the multiple-stage stratified random sampling method, 300 high school students from four counties in Taiwan were invited to participate in this study to evaluate the psychometric properties of Test of Functional Health Literacy in Adolescents. The Functional Health Literacy in Adolescents had good internal consistency reliability and excellent test-retest reliability. Confirmatory factor analysis resulted in a one-factor solution. Contrary to the original version of the Test of Functional Health Literacy in Adolescents, the findings revealed that the 36-item, one-factor model for the Test of Functional Health Literacy in Adolescents is the best-fit model. This is a suitable instrument to assess health literacy levels in Chinese adolescents before health education programmes can be appropriately planned, implemented and evaluated. © 2012 Blackwell Publishing Ltd.

  11. Testing for intracycle determinism in pseudoperiodic time series.

    Science.gov (United States)

    Coelho, Mara C S; Mendes, Eduardo M A M; Aguirre, Luis A

    2008-06-01

    A determinism test is proposed based on the well-known method of the surrogate data. Assuming predictability to be a signature of determinism, the proposed method checks for intracycle (e.g., short-term) determinism in the pseudoperiodic time series for which standard methods of surrogate analysis do not apply. The approach presented is composed of two steps. First, the data are preprocessed to reduce the effects of seasonal and trend components. Second, standard tests of surrogate analysis can then be used. The determinism test is applied to simulated and experimental pseudoperiodic time series and the results show the applicability of the proposed test.

  12. Evaluation of a draft standard on performance specifications for health physics instrumentation: results for environmental tests

    International Nuclear Information System (INIS)

    Kenoyer, J.L.; Swinth, K.L.; Mashburn, K.R.; Selby, J.M.

    1984-06-01

    Draft ANSI Standard N42.17 on performance specifications for health physics instrumentation is currently being evaluated by the Pacific Northwest Laboratory. Evaluation is performed by testing a cross-section of currently available instruments with testing procedures based on specifications of the standard and then determining the degree of conformance to the various elements of the proposed standard. Data will be presented on the performance of a cross-section of beta-gamma survey instruments under various environmental tests. Test results that will be presented include temperature effects, humidity effects, radio frequency (r.f.) susceptibility, ambient pressure effects, vibration effects, and shock effects. Tests performed to date show that most instruments will meet the temperature, humidity, and ambient pressure tests. A large variability is noted among instruments from the same or different vendors. Preliminary r.f. susceptibility tests have shown large artificial responses at some frequencies for specific instruments. The presentation will also include a discussion of procedures used in the testing and weaknesses identified in the proposed standard

  13. Achieving Innovation and Affordability Through Standardization of Materials Development and Testing

    Science.gov (United States)

    Bray, M. H.; Zook, L. M.; Raley, R. E.; Chapman, C.

    2011-01-01

    The successful expansion of development, innovation, and production within the aeronautics industry during the 20th century was facilitated by collaboration of government agencies with the commercial aviation companies. One of the initial products conceived from the collaboration was the ANC-5 Bulletin, first published in 1937. The ANC-5 Bulletin had intended to standardize the requirements of various government agencies in the design of aircraft structure. The national space policy shift in priority for NASA with an emphasis on transferring the travel to low earth orbit to commercial space providers highlights an opportunity and a need for the national and global space industries. The same collaboration and standardization that is documented and maintained by the industry within MIL-HDBK-5 (MMPDS-01) and MIL-HBDK-17 (nonmetallic mechanical properties) can also be exploited to standardize the thermal performance properties, processing methods, test methods, and analytical methods for use in aircraft and spacecraft design and associated propulsion systems. In addition to the definition of thermal performance description and standardization, the standardization for test methods and analysis for extreme environments (high temperature, cryogenics, deep space radiation, etc) would also be highly valuable to the industry. Its subsequent revisions and conversion to MIL-HDBK-5 and then MMPDS-01 established and then expanded to contain standardized mechanical property design values and other related design information for metallic materials used in aircraft, missiles, and space vehicles. It also includes guidance on standardization of composition, processing, and analytical methods for presentation and inclusion into the handbook. This standardization enabled an expansion of the technologies to provide efficiency and reliability to the consumers. It can be established that many individual programs within the government agencies have been overcome with development costs

  14. Comparison of the clonidine test with the insulin tolerance test in the evaluation of patients with short stature

    International Nuclear Information System (INIS)

    Batista, M.C.

    1986-01-01

    Thirty one patients aged 2.9 to 17.5 years, with heights from 1.3 to 85 standard deviations below the mean for age and sex, are studied. Two GH provocative tests are done: (1) insulin tolerance test (ITT): intravenous regular insulin 0.1 U/kg body weight; (2) clonidine test (CLOT): oral clonidine 0.0375 mg/m 2 surface area. Serum GH is measured by a radioimmunoassay method developed in the laboratory and calibrated against a reference preparation provided by the National Institutes of Health. (M.A.C.) [pt

  15. Standard Test Method for Water Absorption of Core Materials for Structural Sandwich Constructions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2001-01-01

    1.1 This test method covers the determination of the relative amount of water absorption by various types of structural core materials when immersed or in a high relative humidity environment. This test method is intended to apply to only structural core materials; honeycomb, foam, and balsa wood. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given may be approximate. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  16. Cell short circuit, preshort signature

    Science.gov (United States)

    Lurie, C.

    1980-01-01

    Short-circuit events observed in ground test simulations of DSCS-3 battery in-orbit operations are analyzed. Voltage signatures appearing in the data preceding the short-circuit event are evaluated. The ground test simulation is briefly described along with performance during reconditioning discharges. Results suggest that a characteristic signature develops prior to a shorting event.

  17. [Standardization of terminology in laboratory medicine I].

    Science.gov (United States)

    Yoon, Soo Young; Yoon, Jong Hyun; Min, Won Ki; Lim, Hwan Sub; Song, Junghan; Chae, Seok Lae; Lee, Chang Kyu; Kwon, Jung Ah; Lee, Kap No

    2007-04-01

    Standardization of medical terminology is essential for data transmission between health-care institutions or clinical laboratories and for maximizing the benefits of information technology. Purpose of our study was to standardize the medical terms used in the clinical laboratory, such as test names, units, terms used in result descriptions, etc. During the first year of the study, we developed a standard database of concept names for laboratory terms, which covered the terms used in government health care centers, their branch offices, and primary health care units. Laboratory terms were collected from the electronic data interchange (EDI) codes from National Health Insurance Corporation (NHIC), Logical Observation Identifier Names and Codes (LOINC) database, community health centers and their branch offices, and clinical laboratories of representative university medical centers. For standard expression, we referred to the English-Korean/ Korean-English medical dictionary of Korean Medical Association and the rules for foreign language translation. Programs for mapping between LOINC DB and EDI code and for translating English to Korean were developed. A Korean standard laboratory terminology database containing six axial concept names such as components, property, time aspect, system (specimen), scale type, and method type was established for 7,508 test observations. Short names and a mapping table for EDI codes and Unified Medical Language System (UMLS) were added. Synonym tables for concept names, words used in the database, and six axial terms were prepared to make it easier to find the standard terminology with common terms used in the field of laboratory medicine. Here we report for the first time a Korean standard laboratory terminology database for test names, result description terms, result units covering most laboratory tests in primary healthcare centers.

  18. Standard-E hydrogen monitoring system shop acceptance test procedure

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, T.C.

    1997-10-02

    The purpose of this report is to document that the Standard-E Hydrogen Monitoring Systems (SHMS-E), fabricated by Mid-Columbia Engineering (MCE) for installation on the Waste Tank Farms in the Hanford 200 Areas, are constructed as intended by the design. The ATP performance will verify proper system fabrication.

  19. Standard-E hydrogen monitoring system shop acceptance test report

    International Nuclear Information System (INIS)

    Schneider, T.C.

    1997-01-01

    The purpose of this report is to document that the Standard-E Hydrogen Monitoring Systems (SHMS-E), fabricated by Mid-Columbia Engineering (MCE) for installation on the Waste Tank Farms in the Hanford 200 Areas, are constructed as intended by the design. The ATP performance will verify proper system fabrication

  20. Dimension yields from short logs of low-quality hardwood trees.

    Science.gov (United States)

    Howard N. Rosen; Harold A. Stewart; David J. Polak

    1980-01-01

    Charts are presented for determining yields of 4/4 dimension cuttings from short hardwood logs of aspen, soft maple, black cherry, yellow-poplar, and black walnut for several cutting grades and bolt sizes. Cost comparisons of short log and standard grade mixes show sizes. Cost comparisons of short log and standard grade mixes show the estimated least expensive...

  1. International Standards on stability of digital prints

    International Nuclear Information System (INIS)

    Adelstein, Peter Z

    2010-01-01

    The International Standards Organization (ISO) is a worldwide recognized standardizing body which has responsibility for standards on permanence of digital prints. This paper is an update on the progress made to date by ISO in writing test methods in this area. Three technologies are involved, namely ink jet, dye diffusion thermal transfer (dye-sublimation) and electrophotography. Two types of test methods are possible, namely comparative tests and predictive tests. To date a comparative test on water fastness has been published and final balloting is underway on a comparative test on humidity fastness. Predictive tests are being finalized on thermal stability and pollution susceptibility. The test method on thermal stability is intended to predict the print life during normal aging. One of the testing concerns is that some prints do not show significant image change in practical testing times. The test method on pollution susceptibility only deals with ozone and assumes that the reciprocity law applies. This law assumes that a long time under a low pollutant concentration is equivalent to a short time under the high concentration used in the test procedure. Longer term studies include a predictive test for light stability and the preparation of a material specification. The latter requires a decision about the proper colour target to be used and what constitutes an unacceptable colour change. Moreover, a specification which gives a predictive life is very dependent upon the conditions the print encounters and will only apply to specific levels of temperature, ozone and light.

  2. Standard test method for measurement of corrosion potentials of Aluminum alloys

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers a procedure for measurement of the corrosion potential (see Note 1) of an aluminum alloy in an aqueous solution of sodium chloride with enough hydrogen peroxide added to provide an ample supply of cathodic reactant. Note 1—The corrosion potential is sometimes referred to as the open-circuit solution or rest potential. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. Standard practice for preparing, cleaning, and evaluating corrosion test specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This practice covers suggested procedures for preparing bare, solid metal specimens for tests, for removing corrosion products after the test has been completed, and for evaluating the corrosion damage that has occurred. Emphasis is placed on procedures related to the evaluation of corrosion by mass loss and pitting measurements. (Warning—In many cases the corrosion product on the reactive metals titanium and zirconium is a hard and tightly bonded oxide that defies removal by chemical or ordinary mechanical means. In many such cases, corrosion rates are established by mass gain rather than mass loss.) 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see 1 and 7.2.

  4. Motor competence assessment in children: convergent and discriminant validity between the BOT-2 Short Form and KTK testing batteries.

    Science.gov (United States)

    Fransen, Job; D'Hondt, Eva; Bourgois, Jan; Vaeyens, Roel; Philippaerts, Renaat M; Lenoir, Matthieu

    2014-06-01

    This study investigated convergent and discriminant validity between two motor competence assessment instruments in 2485 Flemish children: the Bruininks-Oseretsky Test of Motor Proficiency 2 Short Form (BOT-2 Short Form) and the KörperKoördinationsTest für Kinder (KTK). A Pearson correlation assessed the relationship between BOT-2 Short Form total, gross and fine motor composite scores and KTK Motor Quotient in three age cohorts (6-7, 8-9, 10-11 years). Crosstabs were used to measure agreement in classification in children scoring below percentile 5 and 15 and above percentile 85 and 95. Moderately strong positive (r=0.44-0.64) associations between BOT-2 total and gross motor composite scores and KTK Motor Quotient and weak positive correlations between BOT-2 Short Form fine motor composite and KTK Motor Quotient scores (r=0.25-0.37) were found. Levels of agreement were fair to moderate. Therefore, some proof of convergent and discriminant validity between BOT-2 Short Form and KTK was established in this study, underlining the notion that the evaluation of motor competence should not be based upon a single assessment instrument. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Reliability testing of the Danish version of the Kidney Disease Quality of Life Short Form

    DEFF Research Database (Denmark)

    Molsted, Stig; Heaf, James; Prescott, Lotte

    2005-01-01

    . MATERIAL AND METHODS: Translation into Danish and back-translation into English were performed. Pilot, field and internal consistency reliability tests were performed. RESULTS: Cronbach's alpha coefficients for the internal reliability test ranged from 0.77 to 0.93 for the eight generic scales. In a test......OBJECTIVE: The questionnaire Kidney Disease Quality of Life Short Form version 1.3 (KDQOL-SF) is valuable for assessing the health-related quality of life in patients treated with chronic dialysis. The aim of this study was to translate and test the reliability of the KDQOL-SF for use in Denmark...... involving all patients, two of the disease-specific scales had Cronbach's alpha coefficients of test of the scores...

  6. [Procedure of seed quality testing and seed grading standard of Prunus humilis].

    Science.gov (United States)

    Wen, Hao; Ren, Guang-Xi; Gao, Ya; Luo, Jun; Liu, Chun-Sheng; Li, Wei-Dong

    2014-11-01

    So far there exists no corresponding quality test procedures and grading standards for the seed of Prunus humilis, which is one of the important source of base of semen pruni. Therefor we set up test procedures that are adapt to characteristics of the P. humilis seed through the study of the test of sampling, seed purity, thousand-grain weight, seed moisture, seed viability and germination percentage. 50 cases of seed specimens of P. humilis tested. The related data were analyzed by cluster analysis. Through this research, the seed quality test procedure was developed, and the seed quality grading standard was formulated. The seed quality of each grade should meet the following requirements: for first grade seeds, germination percentage ≥ 68%, thousand-grain weight 383 g, purity ≥ 93%, seed moisture ≤ 5%; for second grade seeds, germination percentage ≥ 26%, thousand-grain weight ≥ 266 g, purity ≥ 73%, seed moisture ≤9%; for third grade seeds, germination percentage ≥ 10%, purity ≥ 50%, thousand-grain weight ≥ 08 g, seed moisture ≤ 13%.

  7. RESULTS OF TESTS OF LIGHTNING-RODS WITH UNIVERSAL CLAMPS BY THE APERIODIC IMPULSES OF CURRENT OF ARTIFICIAL LIGHTNING WITH THE PEAK-TEMPORAL PARAMETERS RATIONED ON FOREIGN STANDARDS

    Directory of Open Access Journals (Sweden)

    M.I. Baranov

    2015-06-01

    Full Text Available Purpose. Test in obedience to the requirements of row of operating foreign standards of round metallic lightning-rods with the flat metallic universal clamps of the special type on firmness to direct action of аperiodic impulses of current of temporal form 10/350 μs by amplitude of 50 кА (N− class and 100 кА (H− class. Methodology. The order of leadthrough of these tests is certain the followings normative documents: International IEC 62305-1: 2010, Russian national GOST R IEC 62305-1-2010 and German national DIN EN 50164-1:2008 Standards. Results. Conducted on a powerful high-voltage pulsed current of artificial linear lightning with the peak-temporal parameters and admittances of test rationed on the indicated foreign standards rationed that all of the lightning-rods tested in collection with universal clamps, isolating holders and ceramic elements of roof of technical building were survive electrodynamics and electrothermal action of in-use single short blow of an artificial storm digit. Originality. First in domestic practice the similar model tests of lightning-rods are conducted with universal clamps, executed from different explorer materials, on firmness to flowing to on by it the indicated large impulsive currents of artificial lightning. Practical value. Real firmness to lightning of round copper and zincked steel lightning-rods is certain with the flat copper, zincked steel and non-rusting steel universal clamps of the special execution.

  8. Choose of standard materials in the method of β-testing new materials' mass thickness

    International Nuclear Information System (INIS)

    Chen Zhong

    2007-01-01

    To make sure of the standard mass thickness in beta radials testing mass thickness, this paper calculate using M. C. method and get the result of the relations between the beta radials' transmission rate of different energies and mass thickness in different materials. This result prove that in method of beta test mass thickness choosing materials whose elements are close as standard materials are viable. (authors)

  9. Standard Test Method for Measuring Heat-Transfer Rate Using a Thermal Capacitance (Slug) Calorimeter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method describes the measurement of heat transfer rate using a thermal capacitance-type calorimeter which assumes one-dimensional heat conduction into a cylindrical piece of material (slug) with known physical properties. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. Note 1—For information see Test Methods E 285, E 422, E 458, E 459, and E 511.

  10. Test-Retest Reliability of the Short-Form Survivor Unmet Needs Survey.

    Science.gov (United States)

    Taylor, Karen; Bulsara, Max; Monterosso, Leanne

    2018-01-01

    Reliable and valid needs assessment measures are important assessment tools in cancer survivorship care. A new 30-item short-form version of the Survivor Unmet Needs Survey (SF-SUNS) was developed and validated with cancer survivors, including hematology cancer survivors; however, test-retest reliability has not been established. The objective of this study was to assess the test-retest reliability of the SF-SUNS with a cohort of lymphoma survivors ( n = 40). Test-retest reliability of the SF-SUNS was conducted at two time points: baseline (time 1) and 5 days later (time 2). Test-retest data were collected from lymphoma cancer survivors ( n = 40) in a large tertiary cancer center in Western Australia. Intraclass correlation analyses compared data at time 1 (baseline) and time 2 (5 days later). Cronbach's alpha analyses were performed to assess the internal consistency at both time points. The majority (23/30, 77%) of items achieved test-retest reliability scores 0.45-0.74 (fair to good). A high degree of overall internal consistency was demonstrated (time 1 = 0.92, time 2 = 0.95), with scores 0.65-0.94 across subscales for both time points. Mixed test-retest reliability of the SF-SUNS was established. Our results indicate the SF-SUNS is responsive to the changing needs of lymphoma cancer survivors. Routine use of cancer survivorship specific needs-based assessments is required in oncology care today. Nurses are well placed to administer these assessments and provide tailored information and resources. Further assessment of test-retest reliability in hematology and other cancer cohorts is warranted.

  11. Alternative short tests for inspection and maintenance of in-use cars with respect to their emissions performance

    NARCIS (Netherlands)

    Samaras, Z.; Zachariadis, T.; Joumard, R.; Vernet, I.; Hassel, D.; Weber, F.-J.; Rijkeboer, R.C.

    1998-01-01

    This paper presents the first results of a project aimed at evaluation of a number of short tests that can be alternatively used for Inspection and Maintenance of in-use cars emissions performance. For this purpose, a large number of in-use cars from four European countries was tested according to a

  12. A studentized permutation test for three-arm trials in the 'gold standard' design.

    Science.gov (United States)

    Mütze, Tobias; Konietschke, Frank; Munk, Axel; Friede, Tim

    2017-03-15

    The 'gold standard' design for three-arm trials refers to trials with an active control and a placebo control in addition to the experimental treatment group. This trial design is recommended when being ethically justifiable and it allows the simultaneous comparison of experimental treatment, active control, and placebo. Parametric testing methods have been studied plentifully over the past years. However, these methods often tend to be liberal or conservative when distributional assumptions are not met particularly with small sample sizes. In this article, we introduce a studentized permutation test for testing non-inferiority and superiority of the experimental treatment compared with the active control in three-arm trials in the 'gold standard' design. The performance of the studentized permutation test for finite sample sizes is assessed in a Monte Carlo simulation study under various parameter constellations. Emphasis is put on whether the studentized permutation test meets the target significance level. For comparison purposes, commonly used Wald-type tests, which do not make any distributional assumptions, are included in the simulation study. The simulation study shows that the presented studentized permutation test for assessing non-inferiority in three-arm trials in the 'gold standard' design outperforms its competitors, for instance the test based on a quasi-Poisson model, for count data. The methods discussed in this paper are implemented in the R package ThreeArmedTrials which is available on the comprehensive R archive network (CRAN). Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  13. An improved standard total dose test for CMOS space electronics

    International Nuclear Information System (INIS)

    Fleetwood, D.M.; Winokur, P.S.; Riewe, L.C.; Pease, R.L.

    1989-01-01

    The postirradiation response of hardened and commercial CMOS devices is investigated as a function of total dose, dose rate, and annealing time and temperature. Cobalt-60 irradiation at ≅ 200 rad(SiO 2 )/s followed by a 1-week 100 degrees C biased anneal and testing is shown to be an effective screen of hardened devices for space use. However, a similar screen and single-point test performed after Co-60 irradiation and elevated temperature anneal cannot be generally defined for commercial devices. In the absence of detailed knowledge about device and circuit radiation response, a two-point standard test is proposed to ensure space surviability of CMOS circuits: a Co-60 irradiation and test to screen against oxide-trapped charge related failures, and an additional rebound test to screen against interface-trap related failures. Testing implications for bipolar technologies are also discussed

  14. Evaluation of the E mu-pim-1 transgenic mouse model for short-term carcinogenicity testing

    DEFF Research Database (Denmark)

    van Kreijl, C. F.; van Oordt, C. W. V.; Kroese, E. D.

    1998-01-01

    of T-cell lymphomas. Because of the low incidence of spontaneous tumors and the increased sensitivity to N-ethyl-N-nitrosourea-induced carcinogenesis, E mu-pim-1 mice were suggested to be one of the first potential and attractive candidates to be used in short-term carcinogenicity testing...

  15. Juvenile food limitation in standard tests: a warning to ecotoxicologists.

    NARCIS (Netherlands)

    Zimmer, E.I.; Jager, T.; Ducrot, V.; Kooijman, S.A.L.M.

    2012-01-01

    Standard ecotoxicological tests are as simple as possible and food sources are mainly chosen for practical reasons. Since some organisms change their food preferences during the life-cycle, they might be food limited at some stage if we do not account for such a switch. As organisms tend to respond

  16. Usage of Latent Class Analysis in Diagnostic Microbiology in the Absence of Gold Standard Test

    Directory of Open Access Journals (Sweden)

    Gul Bayram Abiha

    2016-12-01

    Full Text Available The evaluation of performance of various tests diagnostic tests in the absence of gold standard is an important problem. Latent class analysis (LCA is a statistical analysis method known for many years, especially in the absence of a gold standard for evaluation of diagnostic tests so that LCA has found its wide application area. During the last decade, LCA method has widely used in for determining sensivity and specifity of different microbiological tests. It has investigated in the diagnosis of mycobacterium tuberculosis, mycobacterium bovis, human papilloma virus, bordetella pertussis, influenza viruses, hepatitis E virus (HEV, hepatitis C virus (HCV and other various viral infections. Researchers have compared several diagnostic tests for the diagnosis of different pathogens with LCA. We aimed to evaluate performance of latent class analysis method used microbiological diagnosis in various diseases in several researches. When we took into account all of these tests' results, we suppose that LCA is a good statistical analysis method to assess different test performances in the absence of gold standard. [Archives Medical Review Journal 2016; 25(4.000: 467-488

  17. A Multi-Year Plan for Research, Development, and Prototype Testing of Standard Modular Hydropower Technology

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Brennan T. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Welch, Tim [U.S. Department of Energy (DOE), Washington, DC (United States).Office of Energy Efficiency and Renewable Energy (EERE); Witt, Adam M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Stewart, Kevin M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Lee, Kyutae [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); DeNeale, Scott T. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bevelhimer, Mark S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Burress, Timothy A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Pracheil, Brenda M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Pries, Jason L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); O' Connor, Patrick W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Curd, Shelaine L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ekici, Kivanc [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Univ. of Tennessee, Knoxville, TN (United States); Papanicolaou, Thanos [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Univ. of Tennessee, Knoxville, TN (United States); Tsakiris, Achilleas [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Univ. of Tennessee, Knoxville, TN (United States); Kutz, Benjamin [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Univ. of Tennessee, Knoxville, TN (United States); Bishop, Norm [Knight Piesold, Denver, CO (United States); McKeown, Alisha [McKeown and Associates, Moberly, MO (United States); Rabon, Daniel [U.S. Department of Energy (DOE), Washington, DC (United States).Office of Energy Efficiency and Renewable Energy (EERE); Zimmerman, Gregory P. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Uria Martinez, Rocio [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); McManamay, Ryan A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-02-01

    The Multi-Year Plan for Research, Development, and Prototype Testing of Standard Modular Hydropower Technology (MYRP) presents a strategy for specifying, designing, testing, and demonstrating the efficacy of standard modular hydropower (SMH) as an environmentally compatible and cost-optimized renewable electricity generation technology. The MYRP provides the context, background, and vision for testing the SMH hypothesis: if standardization, modularity, and preservation of stream functionality become essential and fully realized features of hydropower technology, project design, and regulatory processes, they will enable previously unrealized levels of new project development with increased acceptance, reduced costs, increased predictability of outcomes, and increased value to stakeholders. To achieve success in this effort, the MYRP outlines a framework of stakeholder-validated criteria, models, design tools, testing facilities, and assessment protocols that will facilitate the development of next-generation hydropower technologies.

  18. [Mokken scaling of the Cognitive Screening Test].

    Science.gov (United States)

    Diesfeldt, H F A

    2009-10-01

    The Cognitive Screening Test (CST) is a twenty-item orientation questionnaire in Dutch, that is commonly used to evaluate cognitive impairment. This study applied Mokken Scale Analysis, a non-parametric set of techniques derived from item response theory (IRT), to CST-data of 466 consecutive participants in psychogeriatric day care. The full item set and the standard short version of fourteen items both met the assumptions of the monotone homogeneity model, with scalability coefficient H = 0.39, which is considered weak. In order to select items that would fulfil the assumption of invariant item ordering or the double monotonicity model, the subjects were randomly partitioned into a training set (50% of the sample) and a test set (the remaining half). By means of an automated item selection eleven items were found to measure one latent trait, with H = 0.67 and item H coefficients larger than 0.51. Cross-validation of the item analysis in the remaining half of the subjects gave comparable values (H = 0.66; item H coefficients larger than 0.56). The selected items involve year, place of residence, birth date, the monarch's and prime minister's names, and their predecessors. Applying optimal discriminant analysis (ODA) it was found that the full set of twenty CST items performed best in distinguishing two predefined groups of patients of lower or higher cognitive ability, as established by an independent criterion derived from the Amsterdam Dementia Screening Test. The chance corrected predictive value or prognostic utility was 47.5% for the full item set, 45.2% for the fourteen items of the standard short version of the CST, and 46.1% for the homogeneous, unidimensional set of selected eleven items. The results of the item analysis support the application of the CST in cognitive assessment, and revealed a more reliable 'short' version of the CST than the standard short version (CST14).

  19. BARTTest: Community-Standard Atmospheric Radiative-Transfer and Retrieval Tests

    Science.gov (United States)

    Harrington, Joseph; Himes, Michael D.; Cubillos, Patricio E.; Blecic, Jasmina; Challener, Ryan C.

    2018-01-01

    Atmospheric radiative transfer (RT) codes are used both to predict planetary and brown-dwarf spectra and in retrieval algorithms to infer atmospheric chemistry, clouds, and thermal structure from observations. Observational plans, theoretical models, and scientific results depend on the correctness of these calculations. Yet, the calculations are complex and the codes implementing them are often written without modern software-verification techniques. The community needs a suite of test calculations with analytically, numerically, or at least community-verified results. We therefore present the Bayesian Atmospheric Radiative Transfer Test Suite, or BARTTest. BARTTest has four categories of tests: analytically verified RT tests of simple atmospheres (single line in single layer, line blends, saturation, isothermal, multiple line-list combination, etc.), community-verified RT tests of complex atmospheres, synthetic retrieval tests on simulated data with known answers, and community-verified real-data retrieval tests.BARTTest is open-source software intended for community use and further development. It is available at https://github.com/ExOSPORTS/BARTTest. We propose this test suite as a standard for verifying atmospheric RT and retrieval codes, analogous to the Held-Suarez test for general circulation models. This work was supported by NASA Planetary Atmospheres grant NX12AI69G, NASA Astrophysics Data Analysis Program grant NNX13AF38G, and NASA Exoplanets Research Program grant NNX17AB62G.

  20. Developing a Standard Method of Test for Packaged, Solid-Desiccant Based Dehumidification Systems

    International Nuclear Information System (INIS)

    Sand, J.R.

    2001-01-01

    A draft Method of Test (MOT) has been proposed for packaged, air-to-air, desiccant-based dehumidifier systems that incorporate a thermally-regenerated desiccant material for dehumidification. This MOT is intended to function as the ''system'' testing and rating compliment to the desiccant ''component'' (desiccant wheels and/or cassettes) MOT (ASHRAE 1998) and rating standard (ARI 1998) already adopted by industry. This draft standard applies to ''packaged systems'' that: Use desiccants for dehumidification of conditioned air for buildings; Use heated air for regeneration of the desiccant material; Include fans for moving process and regeneration air; May include other system components for filtering, pre-cooling, post-cooling, or heating conditioned air; and May include other components for humidification of conditioned air. The proposed draft applies to four different system operating modes depending on whether outdoor or indoor air is used for process air and regeneration air streams . Only the ''ventilation'' mode which uses outdoor air for both process and regeneration inlets is evaluated in this paper. Performance of the dehumidification system is presented in terms that would be most familiar and useful to designers of building HVAC systems to facilitate integration of desiccant equipment with more conventional hardware. Parametric performance results from a modified, commercial desiccant dehumidifier undergoing laboratory testing were used as data input to evaluate the draft standard. Performance results calculated from this experimental input, results from an error-checking/heat-balance verification test built into the standard, and estimated comparisons between desiccant and similarly performing conventional dehumidification equipment are calculated and presented. Some variations in test procedures are suggested to aid in analytical assessment of individual component performance

  1. Standard test method for plutonium by Iron (II)/Chromium (VI) amperometric titration

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of plutonium in unirradiated nuclear-grade plutonium dioxide, uranium-plutonium mixed oxides with uranium (U)/plutonium (Pu) ratios up to 21, plutonium metal, and plutonium nitrate solutions. Optimum quantities of plutonium to measure are 7 to 15 mg. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. Toward a Qualitative Analysis of Standardized Tests Using an Information Processing Model.

    Science.gov (United States)

    Armour-Thomas, Eleanor

    The use of standardized tests and test data to detect and address differences in cognitive styles is advocated here. To this end, the paper describes the componential theory of intelligence addressed by Sternberg et. al. This theory defines the components of intelligence by function and level of generality, including: (1) metacomponents: higher…

  3. Standard Test Method for Electrical Performance of Photovoltaic Cells Using Reference Cells Under Simulated Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of the electrical performance of a photovoltaic cell under simulated sunlight by means of a calibrated reference cell procedure. 1.2 Electrical performance measurements are reported with respect to a select set of standard reporting conditions (SRC) (see Table 1) or to user-specified conditions. 1.2.1 The SRC or user-specified conditions include the cell temperature, the total irradiance, and the reference spectral irradiance distribution. 1.3 This test method is applicable only to photovoltaic cells with a linear response over the range of interest. 1.4 The cell parameters determined by this test method apply only at the time of test, and imply no past or future performance level. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this s...

  4. Standard-B auto grab sampler hydrogen monitoring system, Acceptance Test Report

    International Nuclear Information System (INIS)

    Lott, D.T.

    1995-01-01

    Project W-369, Watch List Tank Hydrogen Monitors, installed a Standard-C Hydrogen Monitoring System (SHMS) on the Flammable gas waste tank AN-104. General Support Projects (8K510) was support by Test Engineering (7CH30) in the performance of the Acceptance Test Procedures (ATP) to qualify the SHMS cabinets on the waste tank. The ATP's performance was controlled by Tank Farm work package. This completed ATP is transmitted by EDT-601748 as an Acceptance Test Report (ATR) in accordance with WHC-6-1, EP 4.2 and EP 1.12

  5. Experimental tests of the standard model

    International Nuclear Information System (INIS)

    Nodulman, L.

    1998-01-01

    The title implies an impossibly broad field, as the Standard Model includes the fermion matter states, as well as the forces and fields of SU(3) x SU(2) x U(1). For practical purposes, I will confine myself to electroweak unification, as discussed in the lectures of M. Herrero. Quarks and mixing were discussed in the lectures of R. Aleksan, and leptons and mixing were discussed in the lectures of K. Nakamura. I will essentially assume universality, that is flavor independence, rather than discussing tests of it. I will not pursue tests of QED beyond noting the consistency and precision of measurements of α EM in various processes including the Lamb shift, the anomalous magnetic moment (g-2) of the electron, and the quantum Hall effect. The fantastic precision and agreement of these predictions and measurements is something that convinces people that there may be something to this science enterprise. Also impressive is the success of the ''Universal Fermi Interaction'' description of beta decay processes, or in more modern parlance, weak charged current interactions. With one coupling constant G F , most precisely determined in muon decay, a huge number of nuclear instabilities are described. The slightly slow rate for neutron beta decay was one of the initial pieces of evidence for Cabbibo mixing, now generalized so that all charged current decays of any flavor are covered

  6. Adaption and Standardization of the Test of Visual-Motor Skills Revised

    Directory of Open Access Journals (Sweden)

    Mozhgan Farahbod

    2004-06-01

    Full Text Available Objective: This research has been carried out with the aim of adaptation, standardization and finding the validity and reliability of Visual-Motor Skills-revised Test for children. Materials & Methods: A multi-stage sampling from the children of the city of Tehran resulted in a sample of 1281 subjects, ages 2,11 through 13,11.the test consisted of 23 geometric designs and each of the designs was assessed through a definite criteria and was scored as errors(weakness and accuracies(strength.For adaptation and standardization of this test, at first step the examiner`s manual and the test items were translated into Farsi. The final form of the test was obtained after performing the pre-tryout and tryout stages, and doing the data analysis by classic model of reliability. Internal consistency coefficients of the subtests were obtained by Cronbach`s Alpha time consistency of the subtests and compound scores were obtained by test-retest. Alpha coefficients for the compound scores were obtained by Guilford formula, which is designed for estimating the compound scores. To obtain the content validity, criterion-related validity and construct validity of the subtests and compound scores, appropriate methods were used. Results: The results obtained ensure the applicability of this test for the evaluation of visual-motor skills of children of Tehran. Conclusion: According to the findings, this test can be used for the disorders in eye-hand coordination, the identification of children with disorders in visual – motor skills. It can also be used for the documentation of the development of fine – motor skills specially in visual – motor skills in 3-14 years – old children.

  7. Standard Practice for Quality Management Systems for Nondestructive Testing Agencies

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This practice covers general requirements for the establishment and maintenance of a quality management system for agencies engaged in nondestructive testing (NDT). 1.2 This practice utilizes criteria contained in Practice E 543. 1.3 This practice utilizes criteria contained in American National Standard ANSI/ISO/ASQ Q9001–2000, Quality management systems—Requirements. 1.4 This practice recognizes the importance of establishing minimum safety criteria. 1.5 The use of SI or inch-pound units, or combinations thereof, will be the responsibility of the technical committee whose standards are referred to in this standard. 1.6 This practice does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this practice to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  8. SUPER-CAPACITOR APPLICATION IN ELECTRICAL POWER CABLE TESTING FACILITIES IN THERMAL ENDURANCE AND MECHANICAL BRACING TESTS

    Directory of Open Access Journals (Sweden)

    I. V. Oleksyuk

    2015-01-01

    Full Text Available The current-carrying cores of the electrical power cables should be resistant to effects of short-circuit currents whose values depend on the material of the core, its cross-sectional area, cable insulation properties, environment temperature, and the duration of the short-circuit current flow (1 and 3–4 sec. when tested for thermal endurance and mechanical bracing. The facilities for testing the 10 kV aluminum core cables with short-circuit current shall provide mechanical-bracing current 56,82 kA and thermal endurance current 11,16 kA. Although capacitors provide such values of the testing currents to the best advantage, utilizing conventional capacitor-units will involve large expenditures for erecting and  running a separate building. It is expedient to apply super-capacitors qua the electric power supply for testing facilities, as they are capacitors with double-electrical layer and involve the current values of tens of kilo-amperes.The insulation voltage during short-circuit current testing being not-standardized, it is not banned to apply voltages less than 10 kV when performing short-circuit thermal endurance and mechanical bracing tests for electrical power cables of 10 kV. The super-capacitor voltage variation-in-time graph consists of two regions: capacitive and resistive. The capacitive part corresponds to the voltage change consequent on the energy change in the super-capacitors. The resistive part shows the voltage variation due to the active resistance presence in the super-capacitor.The author offers the algorithm determining the number of super capacitors requisite for testing 10 kV-electrical power cables with short-circuit currents for thermal endurance and mechanical bracing. The paper shows that installation of super-capacitors in the facilities testing the cables with short-circuit currents reduces the area needed for the super-capacitors in comparison with conventional capacitors more than by one order of magnitude.

  9. Standard test method for determining nodularity and nodule count in ductile iron using image analysis

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method is used to determine the percent nodularity and the nodule count per unit area (that is, number of nodules per mm2) using a light microscopical image of graphite in nodular cast iron. Images generated by other devices, such as a scanning electron microscope, are not specifically addressed, but can be utilized if the system is calibrated in both x and y directions. 1.2 Measurement of secondary or temper carbon in other types of cast iron, for example, malleable cast iron or in graphitic tool steels, is not specifically included in this standard because of the different graphite shapes and sizes inherent to such grades 1.3 This standard deals only with the recommended test method and nothing in it should be construed as defining or establishing limits of acceptability or fitness for purpose of the material tested. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address al...

  10. Diagnostic tests for Helicobacter pylori : A prospective evaluation of their accuracy, without selecting a single test as the gold standard

    NARCIS (Netherlands)

    Thijs, J C; van Zwet, A A; Thijs, W J; Oey, H B; Karrenbeld, A; Stellaard, F; Luijt, D S; Meyer, B C; Kleibeuker, J H

    1996-01-01

    OBJECTIVE: To assess the accuracy of six commonly used diagnostic tests for Helicobacter pylori in a prospective study without using any specific test as the gold standard (the patient was regarded as H. pylori-infected if two or more tests, whatever their nature, were positive). METHODS: In 105

  11. Retrieval practice with short-answer, multiple-choice, and hybrid tests.

    Science.gov (United States)

    Smith, Megan A; Karpicke, Jeffrey D

    2014-01-01

    Retrieval practice improves meaningful learning, and the most frequent way of implementing retrieval practice in classrooms is to have students answer questions. In four experiments (N=372) we investigated the effects of different question formats on learning. Students read educational texts and practised retrieval by answering short-answer, multiple-choice, or hybrid questions. In hybrid conditions students first attempted to recall answers in short-answer format, then identified answers in multiple-choice format. We measured learning 1 week later using a final assessment with two types of questions: those that could be answered by recalling information verbatim from the texts and those that required inferences. Practising retrieval in all format conditions enhanced retention, relative to a study-only control condition, on both verbatim and inference questions. However, there were little or no advantages of answering short-answer or hybrid format questions over multiple-choice questions in three experiments. In Experiment 4, when retrieval success was improved under initial short-answer conditions, there was an advantage of answering short-answer or hybrid questions over multiple-choice questions. The results challenge the simple conclusion that short-answer questions always produce the best learning, due to increased retrieval effort or difficulty, and demonstrate the importance of retrieval success for retrieval-based learning activities.

  12. Standard-Chinese Lexical Neighborhood Test in normal-hearing young children.

    Science.gov (United States)

    Liu, Chang; Liu, Sha; Zhang, Ning; Yang, Yilin; Kong, Ying; Zhang, Luo

    2011-06-01

    The purposes of the present study were to establish the Standard-Chinese version of Lexical Neighborhood Test (LNT) and to examine the lexical and age effects on spoken-word recognition in normal-hearing children. Six lists of monosyllabic and six lists of disyllabic words (20 words/list) were selected from the database of daily speech materials for normal-hearing (NH) children of ages 3-5 years. The lists were further divided into "easy" and "hard" halves according to the word frequency and neighborhood density in the database based on the theory of Neighborhood Activation Model (NAM). Ninety-six NH children (age ranged between 4.0 and 7.0 years) were divided into three different age groups of 1-year intervals. Speech-perception tests were conducted using the Standard-Chinese monosyllabic and disyllabic LNT. The inter-list performance was found to be equivalent and inter-rater reliability was high with 92.5-95% consistency. Results of word-recognition scores showed that the lexical effects were all significant. Children scored higher with disyllabic words than with monosyllabic words. "Easy" words scored higher than "hard" words. The word-recognition performance also increased with age in each lexical category. A multiple linear regression analysis showed that neighborhood density, age, and word frequency appeared to have increasingly more contributions to Chinese word recognition. The results of the present study indicated that performances of Chinese word recognition were influenced by word frequency, age, and neighborhood density, with word frequency playing a major role. These results were consistent with those in other languages, supporting the application of NAM in the Chinese language. The development of Standard-Chinese version of LNT and the establishment of a database of children of 4-6 years old can provide a reliable means for spoken-word recognition test in children with hearing impairment. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  13. Vehicle to Grid Communication Standards Development, Testing and Validation - Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Gowri, Krishnan; Pratt, Richard M.; Tuffner, Francis K.; Kintner-Meyer, Michael CW

    2011-09-01

    In the US, more than 10,000 electric vehicles (EV) have been delivered to consumers during the first three quarters of 2011. A large majority of these vehicles are battery electric, often requiring 220 volt charging. Though the vehicle manufacturers and charging station manufacturers have provided consumers options for charging preferences, there are no existing communications between consumers and the utilities to manage the charging demand. There is also wide variation between manufacturers in their approach to support vehicle charging. There are in-vehicle networks, charging station networks, utility networks each using either cellular, Wi-Fi, ZigBee or other proprietary communication technology with no standards currently available for interoperability. The current situation of ad-hoc solutions is a major barrier to the wide adoption of electric vehicles. SAE, the International Standards Organization/International Electrotechnical Commission (ISO/IEC), ANSI, National Institute of Standards and Technology (NIST) and several industrial organizations are working towards the development of interoperability standards. PNNL has participated in the development and testing of these standards in an effort to accelerate the adoption and development of communication modules.

  14. Asymmetric dark matter annihilation as a test of non-standard cosmologies

    International Nuclear Information System (INIS)

    Gelmini, Graciela B.; Huh, Ji-Haeng; Rehagen, Thomas

    2013-01-01

    We show that the relic abundance of the minority component of asymmetric dark matter can be very sensitive to the expansion rate of the Universe and the temperature of transition between a non-standard pre-Big Bang Nucleosynthesis cosmological phase and the standard radiation dominated phase, if chemical decoupling happens before this transition. In particular, because the annihilation cross section of asymmetric dark matter is typically larger than that of symmetric dark matter in the standard cosmology, the decrease in relic density of the minority component in non-standard cosmologies with respect to the majority component may be compensated by the increase in annihilation cross section, so that the annihilation rate at present of asymmetric dark matter, contrary to general belief, could be larger than that of symmetric dark matter in the standard cosmology. Thus, if the annihilation cross section of the asymmetric dark matter candidate is known, the annihilation rate at present, if detectable, could be used to test the Universe before Big Bang Nucleosynthesis, an epoch from which we do not yet have any data

  15. Standard practice for preparation and use of direct tension stress-corrosion test specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This practice covers procedures for designing, preparing, and using ASTM standard tension test specimens for investigating susceptibility to stress-corrosion cracking. Axially loaded specimens may be stressed quantitatively with equipment for application of either a constant load, constant strain, or with a continuously increasing strain. 1.2 Tension test specimens are adaptable for testing a wide variety of product forms as well as parts joined by welding, riveting, or various other methods. 1.3 The exposure of specimens in a corrosive environment is treated only briefly because other standards are being prepared to deal with this aspect. Meanwhile, the investigator is referred to Practices G35, G36, G37, and G44, and to ASTM Special Technical Publication 425 (1).

  16. Standard Test Methods for Properties of Continuous Filament Carbon and Graphite Fiber Tows

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 These test methods cover the preparation and tensile testing of resin-impregnated and consolidated test specimens made from continuous filament carbon and graphite yarns, rovings, and tows to determine their tensile properties. 1.2 These test methods also cover the determination of the density and mass per unit length of the yarn, roving, or tow to provide supplementary data for tensile property calculation. 1.3 These test methods include a procedure for sizing removal to provide the preferred desized fiber samples for density measurement. This procedure may also be used to determine the weight percent sizing. 1.4 These test methods include a procedure for determining the weight percent moisture adsorption of carbon or graphite fiber. 1.5 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of t...

  17. Short-term stability test for thorium soil candidate a reference material

    Energy Technology Data Exchange (ETDEWEB)

    Clain, Almir F.; Fonseca, Adelaide M.G.; Dantas, Vanessa V.D.B.; Braganca, Maura J.C.; Souza, Poliana S., E-mail: almir@ird.gov.br, E-mail: adelaide@ird.gov.br, E-mail: vanessa@ird.gov.br, E-mail: maura@ird.gov.br, E-mail: poliana@bolsista.ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    This work describes a methodology to determine the soil short-term stability after the steps of production in laboratory. The short-term stability of the soil is an essential property to be determined in order to producing a reference material. The soil is a candidate of reference material for chemical analysis of thorium with metrological traceability to be used in environmental analysis, equipment calibration, validation methods, and quality control. A material is considered stable in a certain temperature if the property of interest does not change with time, considering the analytical random fluctuations. Due to this, the angular coefficient from the graphic of Th concentration versus elapsed time must be near to zero. The analytical determinations of thorium concentration were performed by Instrumental Neutron activation Analysis. The slopes and their uncertainties were obtained from the regression lines at temperatures of 20 deg C and 60 deg C, with control temperature of -20 deg C. From the obtained data a t-test was applied. In both temperatures the calculated t-value was lower than the critical value, so we can conclude with 95% confidence level that no significant changes happened during the period studied concerning thorium concentration in soil at temperatures of 20 deg C and 60 deg C, showing stability at these temperatures. (author)

  18. Short-term stability test for thorium soil candidate a reference material

    International Nuclear Information System (INIS)

    Clain, Almir F.; Fonseca, Adelaide M.G.; Dantas, Vanessa V.D.B.; Braganca, Maura J.C.; Souza, Poliana S.

    2015-01-01

    This work describes a methodology to determine the soil short-term stability after the steps of production in laboratory. The short-term stability of the soil is an essential property to be determined in order to producing a reference material. The soil is a candidate of reference material for chemical analysis of thorium with metrological traceability to be used in environmental analysis, equipment calibration, validation methods, and quality control. A material is considered stable in a certain temperature if the property of interest does not change with time, considering the analytical random fluctuations. Due to this, the angular coefficient from the graphic of Th concentration versus elapsed time must be near to zero. The analytical determinations of thorium concentration were performed by Instrumental Neutron activation Analysis. The slopes and their uncertainties were obtained from the regression lines at temperatures of 20 deg C and 60 deg C, with control temperature of -20 deg C. From the obtained data a t-test was applied. In both temperatures the calculated t-value was lower than the critical value, so we can conclude with 95% confidence level that no significant changes happened during the period studied concerning thorium concentration in soil at temperatures of 20 deg C and 60 deg C, showing stability at these temperatures. (author)

  19. Ultrasonic testing standard of fusion joint for polythylene(PE) pipeline

    International Nuclear Information System (INIS)

    Lee, Euy Jong; Hur, Sam Suk; Chae, Gug Byeong

    2006-01-01

    The polyethylene(PE) pipes are widely used to transport city gas worldwide with steel pipes. Generally, Steel pipe are used for high pressure line and PE pipe for low pressure line whose pressure is less than 4 kg/m 2 . The steel pipe line are subject to 100 percent Radiographic Testing(RT) during installation stage, on the contrary, there has been no the established testing method for the welding fusion joint of polyethylene pipes, so all quality control is limited only Visual Testing(VT) or management of Fusion welding equipment. Even though PE pipeline is exposed to lower pressure than steel pipeline, the gas leakage from PE pipe may result in almost the same serious consequence from steel pipeline. So, it is necessary to develop the reliable testing standard for PE pipeline from the point of view of NDT engineers.

  20. A Study on the Improvement of Safety Testing Standards and Methods for Mammography

    International Nuclear Information System (INIS)

    Choi, Seon Hyeong; Jung, Ah Young; Yong, Hwan Seok; Kim, Do Wan; Jang, Gi Won; Cha, Sang Hoon; Jo, Sang Won; Park, Ji Koon

    2012-01-01

    To establish the improved national safety testing standards and methods for mammography. We investigated and compared the current status of mammographic equipment installation with the national and international safety and quality control programs and methods. We established and verified the draft for safety testing standards and methods. We propose that the investigations of the conductor system, hardware leakage radiation profile, illumination intensity test, comparison between X-ray and light photon exposure, X-ray dose exposure on the chest wall, compression equipment size, timing equipment, and the average effective radiation dose, should all be maintained as they are in the present state without any changes. However, the exposure radiation dose reproducibility, kVp and mAs, and the half value layer tests should be reconsidered and revised. Moreover, compression pressure and autonomic exposure control system (AEC) tests should be included as new criteria. Other parameter controls included in the phantom image analysis which overlap with total quality assurance should be excluded. We recommend that AEC and compression pressure tests should be included as new criteria and the methods for the exposure radiation dose reproducibility, kVp, and mAs, and half value layer tests should be reconsidered and revised.

  1. Testing of camera performance standards at steady and local overloading

    International Nuclear Information System (INIS)

    Keszthelyine Landori, S.; Adorjanne Farkas, M.; Csirik, J.

    1983-01-01

    Camera performance standards are usually given for low count rates and uniform irradiation. A conventional analog gamma camera system (Gamma MB 9100 manufactured under the know-how of Picker DC 4/12 in Hungary) was studied on the basis of the Picker test procedure and the NEMA standard system. Uniformity, linearity, spatial and energy resolution were measured at high count rates and uniform irradiation (steady overloading). Linearity was studied at local overloading. Linearity, spatial and energy resolution were measured by a 1024-channel analyzer-computer system of KFKI, Hungary. The data were evaluated on the basis of NEMA standards, while uniformity was measured by the Gamma data processing system and evaluated by special SEGAMS programs. Performance variations were studied between 7500 cps and 75.000 cps pulse rates. Spatial and energy resolution were influenced strongly, uniformity slightly by pulse rates, while linearity did not change at all. Linearity was not influenced even by local overloading. (author)

  2. Standard test method for measurement of roll wave optical distortion in heat-treated flat glass

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method is applicable to the determination of the peak-to-valley depth and peak-to-peak distances of the out-of-plane deformation referred to as roll wave which occurs in flat, heat-treated architectural glass substrates processed in a heat processing continuous or oscillating conveyance oven. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This test method does not address other flatness issues like edge kink, ream, pocket distortion, bow, or other distortions outside of roll wave as defined in this test method. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. Standardization, Validity and Reliability Study of Gülhane Aphasia Test-2 (GAT-2

    Directory of Open Access Journals (Sweden)

    İlknur Maviş

    2007-04-01

    Full Text Available OBJECTIVE: Gülhane Aphasia Test-2 (GAT-2 has been developed to show the presence of a language disorder ‘aphasia’ and to give the clinician implications for the accompanying speech disorders such as apraxia and dysarthria. OBJECTIVE: The aim of the study was to report standardization, validity and reliability study of GAT-2. METHODS: : 10 healthy individuals were tested initially for the pilot study. 134 healthy individual was included to the standardization study and 30 individuals with aphasia and 11 individuals with right brain injury was included to the validation study. The inter group GAT-2 score differentiations and the effects of age, years of education, sex variances were observed. GAT-2 cut-off scores were calculated by the scores of healthy individuals. GAT-2 test-retest reliability and inter-observer reliability was calculated. RESULTS: Healthy individuals’ GAT-2 scores were significantly different from the GAT-2 scores of aphasic patients, but not from right brain injured patients’. Healthy individuals’ GAT-2 scores were not affected from the sex, age variances but from years of education, so cut-off scores were calculated by this variance. GAT-2 scores of aphasic patients were not affected from age, sex and years of education. Test-retest and inter-observer reliability and internal consistency results showed that GAT-2 is a highly reliable aphasia screening test. CONCLUSION: GAT-2 was found to be a standardized, highly reliable and a valid aphasia test for Turkish stroke patients with aphasia

  4. Toward the establishment of standardized in vitro tests for lipid-based formulations, part 4

    DEFF Research Database (Denmark)

    Williams, Hywel D; Sassene, Philip; Kleberg, Karen

    2014-01-01

    The Lipid Formulation Classification System Consortium looks to develop standardized in vitro tests and to generate much-needed performance criteria for lipid-based formulations (LBFs). This article highlights the value of performing a second, more stressful digestion test to identify LBFs near...... a performance threshold and to facilitate lead formulation selection in instances where several LBF prototypes perform adequately under standard digestion conditions (but where further discrimination is necessary). Stressed digestion tests can be designed based on an understanding of the factors that affect LBF...... development, and facilitate dialogue with the regulatory authorities. This classification system is based on the concept that performance evaluations across three in vitro tests, designed to subject a LBF to progressively more challenging conditions, will enable effective LBF discrimination and performance...

  5. The effect of instructional methodology on high school students natural sciences standardized tests scores

    Science.gov (United States)

    Powell, P. E.

    Educators have recently come to consider inquiry based instruction as a more effective method of instruction than didactic instruction. Experience based learning theory suggests that student performance is linked to teaching method. However, research is limited on inquiry teaching and its effectiveness on preparing students to perform well on standardized tests. The purpose of the study to investigate whether one of these two teaching methodologies was more effective in increasing student performance on standardized science tests. The quasi experimental quantitative study was comprised of two stages. Stage 1 used a survey to identify teaching methods of a convenience sample of 57 teacher participants and determined level of inquiry used in instruction to place participants into instructional groups (the independent variable). Stage 2 used analysis of covariance (ANCOVA) to compare posttest scores on a standardized exam by teaching method. Additional analyses were conducted to examine the differences in science achievement by ethnicity, gender, and socioeconomic status by teaching methodology. Results demonstrated a statistically significant gain in test scores when taught using inquiry based instruction. Subpopulation analyses indicated all groups showed improved mean standardized test scores except African American students. The findings benefit teachers and students by presenting data supporting a method of content delivery that increases teacher efficacy and produces students with a greater cognition of science content that meets the school's mission and goals.

  6. Does exposure to GSM 900 MHz mobile phone radiation affect short-term memory of elementary school students?

    Science.gov (United States)

    Movvahedi, M M; Tavakkoli-Golpayegani, A; Mortazavi, S A R; Haghani, M; Razi, Z; Shojaie-Fard, M B; Zare, M; Mina, E; Mansourabadi, L; Nazari-Jahromi; Safari, A; Shokrpour, N; Mortazavi, S M J

    2014-05-01

    Now-a-days, children are exposed to mobile phone radiation at a very early age. We have previously shown that a large proportion of children in the city of Shiraz, Iran use mobile phones. Furthermore, we have indicated that the visual reaction time (VRT) of university students was significantly affected by a 10 min real/sham exposure to electromagnetic fields emitted by mobile phone. We found that these exposures decreased the reaction time which might lead to a better response to different hazards. We have also revealed that occupational exposures to radar radiations decreased the reaction time in radar workers. The purpose of this study was to investigate whether short-term exposure of elementary school students to radiofrequency (RF) radiation leads to changes in their reaction time and short-term memory. A total of 60 elementary school children ages ranging from 8 to 10 years studying at a public elementary school in Shiraz, Iran were enrolled in this study. Standardized computer-based tests of VRT and short-term memory (modified for children) were administered. The students were asked to perform some preliminary tests for orientation with the VRT test. After orientation, to reduce the random variation of measurements, each test was repeated ten times in both real and sham exposure phases. The time interval between the two subsequent sham and real exposure phases was 30 min. The mean ± standard deviation reaction times after a 10 min talk period and after a 10 min sham exposure (switched off mobile) period were 249.0 ± 82.3 ms and 252.9 ± 68.2 ms (P = 0.629), respectively. On the other hand, the mean short-term memory scores after the talk and sham exposure periods were 1062.60 ± 305.39, and 1003.84 ± 339.68 (P = 0.030), respectively. To the best of our knowledge, this is the first study to show that short-term exposure of elementary school students to RF radiation leads to the better performance of their short-term memory.

  7. Mechanical characteristics of historic mortars from tests on small-sample non-standard on small-sample non-standard specimens

    Czech Academy of Sciences Publication Activity Database

    Drdácký, Miloš; Slížková, Zuzana

    2008-01-01

    Roč. 17, č. 1 (2008), s. 20-29 ISSN 1407-7353 R&D Projects: GA ČR(CZ) GA103/06/1609 Institutional research plan: CEZ:AV0Z20710524 Keywords : small-sample non-standard testing * lime * historic mortar Subject RIV: AL - Art, Architecture, Cultural Heritage

  8. Consensus based reporting standards for diagnostic test accuracy studies for paratuberculosis in ruminants.

    NARCIS (Netherlands)

    Gardner, I.A.; Nielsen, S.S.; Whittington, R.J.; Collins, M.T.; Bakker, D.; Harris, B.; Sreevatsan, S.; Lombard, J.E.; Sweeney, R.; Smith, D.R.; Gavalchin, J.; Eda, S.

    2011-01-01

    The Standards for Reporting of Diagnostic Accuracy (STARD) statement (www.stard-statement.org) was developed to encourage complete and transparent reporting of key elements of test accuracy studies in human medicine. The statement was motivated by widespread evidence of bias in test accuracy studies

  9. Standard Practice for Recording Data from Atmospheric Corrosion Tests of Metallic-Coated Steel Specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice covers a procedure for recording data of atmospheric corrosion tests of metallic-coated steel specimens. Its objective is the assurance of (1) complete identification of materials before testing, (2) objective reporting of material appearance during visual inspections, and (3) adequate photographic, micrographic, and chemical laboratory examinations at specific stages of deterioration, and at the end of the tests. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Standardized procedure for eddy-current testing of stainless steel, thin-walled nuclear fuel element cladding tubes

    Energy Technology Data Exchange (ETDEWEB)

    Barat, P; Raj, B; Bhattacharya, D K [Reactor Research Centre, Kalpakkam (India)

    1982-10-01

    Thin-walled nuclear fuel cladding tubes made of AISI 316 stainless steel have been examined by eddy-current testing. Standardization of the procedures has required investigations on optimizing the test frequency, finding a method to locate a defect with respect to the probe reference end, and the use of standard defects and sequential metallography of natural defects detected by eddy-current testing, to understand the influence of the nature of defects on the impedance output signals. Test frequency and method of locating the defect were optimized by the use of standard defects made by machining in reference cladding tubes. Subsequent metallography of natural defects detected by eddy-current testing revealed mainly clusters of inclusions but also other types of defects. The effect of the distribution of inclusions along the length of the tube on the impedance output is discussed.

  11. Validity of a new assessment rubric for a short-answer test of clinical reasoning.

    Science.gov (United States)

    Yeung, Euson; Kulasagarem, Kulamakan; Woods, Nicole; Dubrowski, Adam; Hodges, Brian; Carnahan, Heather

    2016-07-26

    The validity of high-stakes decisions derived from assessment results is of primary concern to candidates and certifying institutions in the health professions. In the field of orthopaedic manual physical therapy (OMPT), there is a dearth of documented validity evidence to support the certification process particularly for short-answer tests. To address this need, we examined the internal structure of the Case History Assessment Tool (CHAT); this is a new assessment rubric developed to appraise written responses to a short-answer test of clinical reasoning in post-graduate OMPT certification in Canada. Fourteen physical therapy students (novices) and 16 physical therapists (PT) with minimal and substantial OMPT training respectively completed a mock examination. Four pairs of examiners (n = 8) participated in appraising written responses using the CHAT. We conducted separate generalizability studies (G studies) for all participants and also by level of OMPT training. Internal consistency was calculated for test questions with more than 2 assessment items. Decision studies were also conducted to determine optimal application of the CHAT for OMPT certification. The overall reliability of CHAT scores was found to be moderate; however, reliability estimates for the novice group suggest that the scale was incapable of accommodating for scores of novices. Internal consistency estimates indicate item redundancies for several test questions which will require further investigation. Future validity studies should consider discriminating the clinical reasoning competence of OMPT trainees strictly at the post-graduate level. Although rater variance was low, the large variance attributed to error sources not incorporated in our G studies warrant further investigations into other threats to validity. Future examination of examiner stringency is also warranted.

  12. [Study on seed quality test and quality standard of Lonicera macranthoides].

    Science.gov (United States)

    Zhang, Ying; Xu, Jin; Li, Long-Yun; Cui, Guang-Lin; She, Yue-Hui

    2016-04-01

    Referring to the rules for agricultural seed testing (GB/T 3543-1995) issued by China, the test of sampling, purity, thousand seed weight, moisture, viability, relative conductivity and germination rate had been studied for seed quality test methods of Lonicera macranthoides. The seed quality from 38 different collection areas was measured to establish quality classification standard by K-means clustering. The results showed that at least 7.5 g seeds should be sampled, and passed 20-mesh sieve for purity analysis.The 500-seed method used to measure thousand seed weight. The moisture was determined by crushed seeds dried in high temperature (130±2) ℃ for 3 h.The viability determined by 25 ℃ 0.1% TTC stained 5h in dark. 1.0 g seeds soaked in 50 ml ultra pure water in 25 ℃ for 12 hours to determine the relative conductivity. The seed by 4 ℃stratification for 80 days were cultured on paper at 15 ℃. Quality of the seeds from different areas was divided into three grades. The primary seed quality classification standard was established.The I grade and II grade were recommend use in production. Copyright© by the Chinese Pharmaceutical Association.

  13. Testing of Commercial Milk Production Technology Using A Combination of High Temperature Short Time and Pulsed Electric Field

    OpenAIRE

    Hadi A; Widjanarko SB; Kusnadi J

    2016-01-01

    The development of milk processing technology has grown excessively, and it contains advantage and disadvantage. This study used mixed between PEF (Pulsed Electric Field) and High Temperature Short Time (HTST) to produce milk processed product which is effective and efficient in killing milk microorganism without changing its color, scent, and nutrient content of processed product, therefore producing commercial sterile milk product in accord with milk Indonesian National Standard (SNI). The ...

  14. Application of ISRM testing methods to fracture toughness testing of graphite

    International Nuclear Information System (INIS)

    Hashida, T.; Fukasawa, T.; Takahashi, H.; Ishiyama, S.; Oku, T.

    1987-01-01

    Fracture toughness measurements of nuclear grade graphites, IG11 and PGX, were made by means of AE technique. Tests were conducted on edge-notched round bend bar, edge-notched short bar and round compact tension specimens. These round-shaped specimens used in this study have been proposed for standard fracture toughness tests of rock as a draft of testing standard of International Society for Rock Mechanics (ISRM). Taking the observed nonlinear deformation behavior into account, J-integral approach was utilized to determine the fracture toughness of the graphites. It is shown that the critical J integral determined by AE technique, J iAE , is independent of specimen geometry. Based on this experimental results, the fracture toughness K IC of the graphites was determined from the J iAE values. K IC value of IG11 was 1.04 MPa√m, and 0.77 MPa√m for PGX respectively. Furthermore, the specimen size effect of the fracture toughness determined by the J-integral/AE method is discussed. (author)

  15. Nuclear reactor pressure vessel surveillance capsule examinations. Application of American Society for Testing and Materials Standards

    International Nuclear Information System (INIS)

    Perrin, J.S.

    1978-01-01

    A series of pressure vessel surveillance capsules is installed in each commercial nuclear power plant in the United States. A capsule typically contains neutron dose meters, thermal monitors, tensile specimens, and Charpy V-notch impact specimens. In order to determine property changes of the pressure vessel resulting from irradiation, surveillance capsules are periodically removed during the life of a reactor and examined. There are numerous standards, regulations, and codes governing US pressure vessel surveillance capsule programmes. These are put out by the US Nuclear Regulatory Commission, the Boiler and Pressure Vessel Committee of the American Society of Mechanical Engineers, and the American Society for Testing and Materials (ASTM). A majority of the pertinent ASTM standards are under the jurisdiction of ASTM Committee E-10 on Nuclear Applications and Measurements of Radiation Effects. The standards, regulations, and codes pertaining to pressure vessel surveillance play an important role in ensuring reliability of the nuclear pressure vessels. ASTM E 185-73 is the Standard Recommended Practice for Surveillance Tests for Nuclear Reactors. This standard recommends procedures for both the irradiation and subsequent testing of surveillance capsules. ASTM E 185-73 references many additional specialized ASTM standards to be followed in specific areas of a surveillance capsule examination. A key element of surveillance capsule programmes is the Charpy V-notch impact test, used to define curves of fracture behaviour over a range of temperatures. The data from these tests are used to define the adjusted reference temperature used in determining pressure-temperature operating curves for a nuclear power plant. (author)

  16. Extracting biologically significant patterns from short time series gene expression data

    Directory of Open Access Journals (Sweden)

    McGinnis Thomas

    2009-08-01

    Full Text Available Abstract Background Time series gene expression data analysis is used widely to study the dynamics of various cell processes. Most of the time series data available today consist of few time points only, thus making the application of standard clustering techniques difficult. Results We developed two new algorithms that are capable of extracting biological patterns from short time point series gene expression data. The two algorithms, ASTRO and MiMeSR, are inspired by the rank order preserving framework and the minimum mean squared residue approach, respectively. However, ASTRO and MiMeSR differ from previous approaches in that they take advantage of the relatively few number of time points in order to reduce the problem from NP-hard to linear. Tested on well-defined short time expression data, we found that our approaches are robust to noise, as well as to random patterns, and that they can correctly detect the temporal expression profile of relevant functional categories. Evaluation of our methods was performed using Gene Ontology (GO annotations and chromatin immunoprecipitation (ChIP-chip data. Conclusion Our approaches generally outperform both standard clustering algorithms and algorithms designed specifically for clustering of short time series gene expression data. Both algorithms are available at http://www.benoslab.pitt.edu/astro/.

  17. SEU testing of a novel hardened register implemented using standard CMOS technology

    International Nuclear Information System (INIS)

    Monnier, T.; Roche, F.M.; Cosculluela, J.; Velazco, R.

    1999-01-01

    A novel memory structure, designed to tolerate SEU perturbations, has been implemented in registers and tested. The design was completed using a standard submicron nonradiation hardened CMOS technology. This paper presents the results of heavy ions tests which evidence the noticeable improvement of the SEU-robustness with an increased LET threshold and reduced cross-section, without significant impact to die real estate, write time, or power consumption

  18. Standard test method for initial screening of corrosion inhibiting admixtures for steel in concrete

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method covers a procedure for determining the effects of chemical admixtures on the corrosion of metals in concrete. This test method can be used to evaluate materials intended to inhibit chloride-induced corrosion of steel in concrete. It can also be used to evaluate the corrosivity of admixtures by themselves or in a chloride environment. This test is not applicable for emulsions. 1.2 &solely-SI-units; 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. The Development and Validation of the Test Of Astronomy STandards (TOAST)

    Science.gov (United States)

    Slater, Stephanie J.

    2014-01-01

    The Test Of Astronomy STandards (TOAST) is a comprehensive assessment instrument designed to measure students' general astronomy content knowledge. Built upon the research embedded within a generation of astronomy assessments designed to measure single concepts, the TOAST is appropriate to measure across an entire astronomy course. The TOAST's…

  20. Standard test method for ranking resistance of materials to sliding wear using block-on-ring wear test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers laboratory procedures for determining the resistance of materials to sliding wear. The test utilizes a block-on-ring friction and wear testing machine to rank pairs of materials according to their sliding wear characteristics under various conditions. 1.2 An important attribute of this test is that it is very flexible. Any material that can be fabricated into, or applied to, blocks and rings can be tested. Thus, the potential materials combinations are endless. However, the interlaboratory testing has been limited to metals. In addition, the test can be run with various lubricants, liquids, or gaseous atmospheres, as desired, to simulate service conditions. Rotational speed and load can also be varied to better correspond to service requirements. 1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. Wear test results are reported as the volume loss in cubic millimetres for both the block and ring. Materials...

  1. JSME construction standard for superconducting magnets of fusion facilities. Toward the construction of ITER

    International Nuclear Information System (INIS)

    Nakasone, Yuji; Takahashi, Yukio; Sato, Kazuyoshi; Nishimura, Arata; Suzuki, Tetsuya; Irie, Hirosada; Nakahira, Masataka

    2009-01-01

    The present paper describes the general view of the construction standard, which the Japan Society of Mechanical Engineers (JSME) has recently set up and published, for superconducting magnet structures to be used in nuclear fusion facilities. The present target of the standard is tokamak-type fusion energy facilities, especially the International Thermonuclear Experimental Reactor called ITER for short. The standard contains rules for structural materials including cryogenic materials, structural design considering magnetic forces, manufacture including welding and installation, nondestructive testing, pressure proof tests and leak tests of toroidal field magnet structures. The standard covers requirements for structural integrity, deformation control, and leak tightness of all the components of the superconducting magnets and their supports except for superconducting strands and electrical insulators. The standard does not cover deterioration, which may occur in service as a result of corrosion, radiation effects, or instability of material. The standard consists of seven articles and twelve mandatory and non-mandatory appendices to the articles; i.e., (1) Scope, roles and responsibilities, (2) Materials, (3) Structural design, (4) Fabrication and installation, (5) Non-destructive examination, (6) Pressure and leak testing, and (7) Terms used in general requirements. (author)

  2. SDT: The Brazilian Standardization of the Silver Drawing Test of Cognition and Emotion.

    Science.gov (United States)

    Allessandrini, Cristina Dias; Duarte, Jose Luclano Miranda; Bianco, Marisa Fernandes; Dupas, Margarida Azevedo

    1998-01-01

    The Silver Drawing Test of Cognition and Emotion was standardized for Brazilian children (N=2,000). ANOVA results are presented for age and education groups from early grades on, including distinguishing adult education levels; results are compared for U.S. and Brazilian populations. Growth in test scores, emotional content responses, and…

  3. [Precautions of physical performance requirements and test methods during product standard drafting process of medical devices].

    Science.gov (United States)

    Song, Jin-Zi; Wan, Min; Xu, Hui; Yao, Xiu-Jun; Zhang, Bo; Wang, Jin-Hong

    2009-09-01

    The major idea of this article is to discuss standardization and normalization for the product standard of medical devices. Analyze the problem related to the physical performance requirements and test methods during product standard drafting process and make corresponding suggestions.

  4. Standard test method for determining the susceptibility to intergranular corrosion of 5XXX series Aluminum alloys by mass loss after exposure to nitric acid (NAMLT Test)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This test method describes a procedure for constant immersion intergranular corrosion testing of 5XXX series aluminum alloys. 1.2 This test method is applicable only to wrought products. 1.3 This test method covers type of specimen, specimen preparation, test environment, and method of exposure. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Standard test method for creep-fatigue testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of mechanical properties pertaining to creep-fatigue deformation or crack formation in nominally homogeneous materials, or both by the use of test specimens subjected to uniaxial forces under isothermal conditions. It concerns fatigue testing at strain rates or with cycles involving sufficiently long hold times to be responsible for the cyclic deformation response and cycles to crack formation to be affected by creep (and oxidation). It is intended as a test method for fatigue testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. The cyclic conditions responsible for creep-fatigue deformation and cracking vary with material and with temperature for a given material. 1.2 The use of this test method is limited to specimens and does not cover testing of full-scale components, structures, or consumer products. 1.3 This test method is primarily ...

  6. An IEC standard on quality assurance for diagnostic X-ray systems

    International Nuclear Information System (INIS)

    Boer, J.A. den

    1985-01-01

    A presentation is given of some characteristics of the International Electrotechnical Commission (IEC). This is followed by a short discussion of general aspects of quality assurance in the diagnostic department. From this discussion it becomes apparent to which aspects of quality assurance IEC can contribute. Within that framework a working group of Sub-Committee 62 is at present active in developing a standard on quality assurance for diagnostic X-ray systems. The standard will contain a set of constancy tests that is claimed to allow a balanced quality assurance programme. The democratic procedure of IEC should guarantee that the proposed standard gains wide acceptance. (author)

  7. The Quest for Standard Tests in Prioritizing Water Use Rights in ...

    African Journals Online (AJOL)

    Moreover, there are problems of depletion, pollution, water grabbing, wastage of water, and water crisis that are attributable to lack of comprehensive regulations, or confusions in putting policy options. The regulatory tools lack clarity and sufficiency with regard to the incorporation of standard tests. There is thus the need for ...

  8. The internal consistency of the standard gamble: tests after adjusting for prospect theory.

    Science.gov (United States)

    Oliver, Adam

    2003-07-01

    This article reports a study that tests whether the internal consistency of the standard gamble can be improved upon by incorporating loss weighting and probability transformation parameters in the standard gamble valuation procedure. Five alternatives to the standard EU formulation are considered: (1) probability transformation within an EU framework; and, within a prospect theory framework, (2) loss weighting and full probability transformation, (3) no loss weighting and full probability transformation, (4) loss weighting and no probability transformation, and (5) loss weighting and partial probability transformation. Of the five alternatives, only the prospect theory formulation with loss weighting and no probability transformation offers an improvement in internal consistency over the standard EU valuation procedure.

  9. Inter-rater reliability of three standardized functional tests in patients with low back pain

    Science.gov (United States)

    Tidstrand, Johan; Horneij, Eva

    2009-01-01

    Background Of all patients with low back pain, 85% are diagnosed as "non-specific lumbar pain". Lumbar instability has been described as one specific diagnosis which several authors have described as delayed muscular responses, impaired postural control as well as impaired muscular coordination among these patients. This has mostly been measured and evaluated in a laboratory setting. There are few standardized and evaluated functional tests, examining functional muscular coordination which are also applicable in the non-laboratory setting. In ordinary clinical work, tests of functional muscular coordination should be easy to apply. The aim of this present study was to therefore standardize and examine the inter-rater reliability of three functional tests of muscular functional coordination of the lumbar spine in patients with low back pain. Methods Nineteen consecutive individuals, ten men and nine women were included. (Mean age 42 years, SD ± 12 yrs). Two independent examiners assessed three tests: "single limb stance", "sitting on a Bobath ball with one leg lifted" and "unilateral pelvic lift" on the same occasion. The standardization procedure took altered positions of the spine or pelvis and compensatory movements of the free extremities into account. The inter-rater reliability was analyzed by Cohen's kappa coefficient (κ) and by percentage agreement. Results The inter-rater reliability for the right and the left leg respectively was: for the single limb stance very good (κ: 0.88–1.0), for sitting on a Bobath ball good (κ: 0.79) and very good (κ: 0.88) and for the unilateral pelvic lift: good (κ: 0.61) and moderate (κ: 0.47). Conclusion The present study showed good to very good inter-rater reliability for two standardized tests, that is, the single-limb stance and sitting on a Bobath-ball with one leg lifted. Inter-rater reliability for the unilateral pelvic lift test was moderate to good. Validation of the tests in their ability to evaluate lumbar

  10. Inter-rater reliability of three standardized functional tests in patients with low back pain

    Directory of Open Access Journals (Sweden)

    Tidstrand Johan

    2009-06-01

    Full Text Available Abstract Background Of all patients with low back pain, 85% are diagnosed as "non-specific lumbar pain". Lumbar instability has been described as one specific diagnosis which several authors have described as delayed muscular responses, impaired postural control as well as impaired muscular coordination among these patients. This has mostly been measured and evaluated in a laboratory setting. There are few standardized and evaluated functional tests, examining functional muscular coordination which are also applicable in the non-laboratory setting. In ordinary clinical work, tests of functional muscular coordination should be easy to apply. The aim of this present study was to therefore standardize and examine the inter-rater reliability of three functional tests of muscular functional coordination of the lumbar spine in patients with low back pain. Methods Nineteen consecutive individuals, ten men and nine women were included. (Mean age 42 years, SD ± 12 yrs. Two independent examiners assessed three tests: "single limb stance", "sitting on a Bobath ball with one leg lifted" and "unilateral pelvic lift" on the same occasion. The standardization procedure took altered positions of the spine or pelvis and compensatory movements of the free extremities into account. The inter-rater reliability was analyzed by Cohen's kappa coefficient (κ and by percentage agreement. Results The inter-rater reliability for the right and the left leg respectively was: for the single limb stance very good (κ: 0.88–1.0, for sitting on a Bobath ball good (κ: 0.79 and very good (κ: 0.88 and for the unilateral pelvic lift: good (κ: 0.61 and moderate (κ: 0.47. Conclusion The present study showed good to very good inter-rater reliability for two standardized tests, that is, the single-limb stance and sitting on a Bobath-ball with one leg lifted. Inter-rater reliability for the unilateral pelvic lift test was moderate to good. Validation of the tests in their

  11. Standard Test Method for Dust Erosion Resistance of Optical and Infrared Transparent Materials and Coatings

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the resistance of transparent plastics and coatings used in aerospace windscreens, canopies, and viewports to surface erosion as a result of dust impingement. This test method simulates flight through a defined particle cloud environment by means of independent control of particle size, velocity, impact angle, mass loading, and test duration. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  12. Development of test practice requirements for a standard method on fracture toughness testing in the transition range

    International Nuclear Information System (INIS)

    McCabe, D.E.; Zerbst, U.; Heerens, J.

    1993-01-01

    This report covers the resolution of several issues that are relevant to the ductile to brittle transition range of structural steels. One of this issues was to compare a statistical-based weakest-link method to constraint data adjustment methods for modeling the specimen size effects on fracture toughness. Another was to explore the concept of a universal transition temperature curve shape (Master Curve). Data from a Materials Properties Council round robin activity were used to test the proposals empirically. The findings of this study are inclosed in an activity for the development of a draft standard test procedure ''Test Practice for Fracture Toughness in the Transition Range''. (orig.) [de

  13. Aligning English grammar testing with European language standards

    Directory of Open Access Journals (Sweden)

    Bodrič Radmila

    2015-01-01

    Full Text Available In recent years, foreign language testing has gained in significance with the advent of The Common European Framework of Reference for Languages (2001 (CEFR, a European language document which set comparable standards for learning, teaching and assessing foreign languages. The CEFR was used to set the research aim of this paper - testing grammar at level B2. The main aim of the research was to determine grammatical competence at level B2 and additional aims included: (a determining which particular areas of grammar need to be learned by students at level B2, (b formulating grammatical descriptors for each individual area of grammar, (c determining the test’s threshold level which would fulfil the criteria for grammatical competence at level B2, and (d determining the extent to which students have mastered the given areas. The pre-testing was followed by the main testing on the sample of 164 students in two secondary schools. The results indicated that the quantity and quality of grammatical competence was lower than expected: 47% of the population failed to fulfil the basic level of grammatical competence. The causes may be attributed to the factors of a subjective and objective nature. Level B2 is demanding qualitatively as well as quantitatively, regarding both the formal and the functional complexity and scope of language use, which requires intensive language production, high levels of motivation and sound working habits in order to master the given grammatical structures.

  14. On the universality of the long-/short-range separation in multiconfigurational density-functional theory

    Science.gov (United States)

    Fromager, Emmanuel; Toulouse, Julien; Jensen, Hans Jørgen Aa.

    2007-02-01

    In many cases, the dynamic correlation can be calculated quite accurately and at a fairly low computational cost in Kohn-Sham density-functional theory (KS-DFT), using current standard approximate functionals. However, in general, KS-DFT does not treat static correlation effects (near degeneracy) adequately which, on the other hand, can be described in wave-function theory (WFT), for example, with a multiconfigurational self-consistent field (MCSCF) model. It is therefore of high interest to develop a hybrid model which combines the best of both WFT and DFT approaches. The merge of WFT and DFT can be achieved by splitting the two-electron interaction into long-range and short-range parts. The long-range part is then treated by WFT and the short-range part by DFT. In this work the authors consider the so-called "erf" long-range interaction erf(μr12)/r12, which is based on the standard error function, and where μ is a free parameter which controls the range of the long-/short-range decomposition. In order to formulate a general method, they propose a recipe for the definition of an optimal μopt parameter, which is independent of the approximate short-range functional and the approximate wave function, and they discuss its universality. Calculations on a test set consisting of He, Be, Ne, Mg, H2, N2, and H2O yield μopt≈0.4a.u.. A similar analysis on other types of test systems such as actinide compounds is currently in progress. Using the value of 0.4a.u. for μ, encouraging results are obtained with the hybrid MCSCF-DFT method for the dissociation energies of H2, N2, and H2O, with both short-range local-density approximation and PBE-type functionals.

  15. Standard test method for color and color difference of whitewares by abriged spectrophotometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2001-01-01

    1.1 This test method describes the instrumental measurement of the reflection properties and color of ceramic glazes and other whitewares by the use of a spectrophotometer or spectrocolorimeter with a hemispherical optical measuring system, such as an integrating sphere. 1.2 The test method is suitable for use with most specimens having an exterior flat surface large enough to cover the spectrophotometer sample port. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  16. Standard model group, QCD subgroup - dynamics isolating and testing the elementary QCD subprocess

    International Nuclear Information System (INIS)

    Tannenbaum, M.J.

    1982-01-01

    QCD to an experimentalist is the theory of interactions of quarks and gluons. Experimentalists like QCD because QCD is analogous to QED. Thus, following Drell and others who have for many years studied the validity of QED, one has a ready-made menu for tests of QCD. There are the static and long distance tests. These topics are covered by Peter LePage in the static properties group. In this report, dynamic and short distance tests of QCD will be discussed, primarily via reactions with large transverse momenta. This report is an introduction and overview of the subject, to serve as a framework for other reports from the subgroup. In the last two sections, the author has taken the opportunity to discuss his own ideas and opinions

  17. Evaluation of a draft standard on performance specifications for health physics instrumentation. Initial results for radiological tests

    International Nuclear Information System (INIS)

    Swinth, K.L.; Kenoyer, J.L.; Mileham, A.P.; Kathren, R.L.; Selby, J.M.

    1983-06-01

    The draft ANSI standard N42.17D2 on performance specifications for health physics instrumentation is currently being evaluated by the Pacific Northwest Laboratory. The primary objective of the project is the evaluation of the applicability and practicality of the proposed standard through testing of a cross-section of currently available commercial instruments to determine how well they conform to the standard. The standard is being tested against instruments such as ionization chambers, G.M. detectors, alpha survey meters, and neutron dose equivalent survey meters. This paper presents results of the preliminary radiological performance tests on ionization chambers and G.M. detectors. This includes both the data generated during the tests and a discussion of procedures developed to perform the testing. Results are reported for response time, accuracy, precision, radiation overloads, and angular dependence. In addition, results are reported for parameters that affect instrument performance including battery lifetime, geotropism and stability. Initial test indicates that some of the instruments will not meet the criteria specified in ANSI N42.17D2. Results cover approximately 40 instruments that have been obtained by direct purchase, by loan from instrument vendors or by loan from others including DOE licensees

  18. ACCESS, Absolute Color Calibration Experiment for Standard Stars: Integration, Test, and Ground Performance

    Science.gov (United States)

    Kaiser, Mary Elizabeth; Morris, Matthew; Aldoroty, Lauren; Kurucz, Robert; McCandliss, Stephan; Rauscher, Bernard; Kimble, Randy; Kruk, Jeffrey; Wright, Edward L.; Feldman, Paul; Riess, Adam; Gardner, Jonathon; Bohlin, Ralph; Deustua, Susana; Dixon, Van; Sahnow, David J.; Perlmutter, Saul

    2018-01-01

    Establishing improved spectrophotometric standards is important for a broad range of missions and is relevant to many astrophysical problems. Systematic errors associated with astrophysical data used to probe fundamental astrophysical questions, such as SNeIa observations used to constrain dark energy theories, now exceed the statistical errors associated with merged databases of these measurements. ACCESS, “Absolute Color Calibration Experiment for Standard Stars”, is a series of rocket-borne sub-orbital missions and ground-based experiments designed to enable improvements in the precision of the astrophysical flux scale through the transfer of absolute laboratory detector standards from the National Institute of Standards and Technology (NIST) to a network of stellar standards with a calibration accuracy of 1% and a spectral resolving power of 500 across the 0.35‑1.7μm bandpass. To achieve this goal ACCESS (1) observes HST/ Calspec stars (2) above the atmosphere to eliminate telluric spectral contaminants (e.g. OH) (3) using a single optical path and (HgCdTe) detector (4) that is calibrated to NIST laboratory standards and (5) monitored on the ground and in-flight using a on-board calibration monitor. The observations are (6) cross-checked and extended through the generation of stellar atmosphere models for the targets. The ACCESS telescope and spectrograph have been designed, fabricated, and integrated. Subsystems have been tested. Performance results for subsystems, operations testing, and the integrated spectrograph will be presented. NASA sounding rocket grant NNX17AC83G supports this work.

  19. Standard and applied material testing methods of austenitic CrNi stainless steels in different nitric acid media - procedures and results

    International Nuclear Information System (INIS)

    Leistikow, S.; Kraft, R.; Schanz, G.

    1989-07-01

    Extended ASTM Standard Huey Testing has been performed in at 120 0 C boiling 14.4 molar (65%) nitric acid during 15 periods (15x48 = 720 h duration) for quality control of numerous commercial nitric acid resistant austenitic CrNi steels. It was shown how sensitively the chosen testing conditions could differentiate between CrNi steels of the same nominal composition as specified for DIN W.Nr. 1.4306 (AISI Type 304 L), but with varying residual element contents. Within an attempt to differentiate within this group of steels by application of electrochemical methods, potentiostatic tests at 1250 mV in nitric acid of equal concentration and temperature were able to detect remarkable differences in corrosion behaviour already after one hour. Another approach, more typical for the electrochemical potentials during materials application in reprocessing plants of nuclear fuel, gave preference to long-term immersion tests, which were performed in nitric acid of lower concentration and temperature. Reference tests in pure 7 molar, 90 0 C nitric acid could only reveal by surface attack small differences in steel quality by exposures of 720 h duration. To shorten the test time by an increase of the redox potential chromium (VI) ions were added to the nitric acid. In a solution of 0,5 g Gr (VI)/l at 90 0 C remarkable differences in corrosion behavior of the steels - similar to the Huey test results - became measurable by means of gravimetry and metallography already during a short-term exposure of 24-71 h. (orig./MM) [de

  20. Electric Vehicle Communications Standards Testing and Validation - Phase II: SAE J2931/1

    Energy Technology Data Exchange (ETDEWEB)

    Pratt, Richard M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Gowri, Krishnan [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-01-15

    Vehicle to grid communication standards enable interoperability among vehicles, charging stations and utility providers and provide the capability to implement charge management. Several standards initiatives by the Society of Automobile Engineers (SAE), International Standards Organization and International Electrotechnical Commission (ISO/IEC), and ZigBee/HomePlug Alliance are developing requirements for communication messages and protocols. Recent work by the Electric Power Research Institute (EPRI) in collaboration with SAE and automobile manufacturers has identified vehicle to grid communication performance requirements and developed a test plan as part of SAE J2931/1 committee work. This laboratory test plan was approved by the SAE J2931/1 committee and included test configurations, test methods, and performance requirements to verify reliability, robustness, repeatability, maximum communication distance, and authentication features of power line carrier (PLC) communication modules at the internet protocol layer level. The goal of the testing effort was to select a communication technology that would enable automobile manufacturers to begin the development and implementation process. The EPRI/Argonne National Laboratory (ANL)/Pacific Northwest National Laboratory (PNNL) testing teams divided the testing so that results for each test could be presented by two teams, performing the tests independently. The PNNL team performed narrowband PLC testing including the Texas Instruments (TI) Concerto, Ariane Controls AC-CPM1, and the MAXIM Tahoe 2 evaluation boards. The scope of testing was limited to measuring the vendor systems communication performance between Electric Vehicle Support Equipment (EVSE) and plug-in electric vehicles (PEV). The testing scope did not address PEV’s CAN bus to PLC or PLC to EVSE (Wi-Fi, cellular, PLC Mains, etc.) communication integration. In particular, no evaluation was performed to delineate the effort needed to translate the IPv6

  1. The Genomic Standards Consortium

    DEFF Research Database (Denmark)

    Field, Dawn; Amaral-Zettler, Linda; Cochrane, Guy

    2011-01-01

    Standards Consortium (GSC), an open-membership organization that drives community-based standardization activities, Here we provide a short history of the GSC, provide an overview of its range of current activities, and make a call for the scientific community to join forces to improve the quality...

  2. Polish Adult Reading Test (PART) - construction of Polish test for estimating the level of premorbid intelligence in schizophrenia.

    Science.gov (United States)

    Karakuła-Juchnowicz, Hanna; Stecka, Mariola

    2017-08-29

    In view of unavailability in Poland of the standardized methods to measure PIQ, the aim of the work was to develop a Polish test to assess the premorbid level of intelligence - PART(Polish AdultReading Test) and to measureits psychometric properties, such as validity, reliability as well as standardization in the group of schizophrenia patients. The principles of PART construction were based on the idea of popular worldwide National Adult Reading Test by Hazel Nelson. The research comprised a group of 122 subjects (65 schizophrenia patients and 57 healthy people), aged 18-60 years, matched for age and gender. PART appears to be a method with high internal consistency and reliability measured by test-retest, inter-rater reliability, and the method with acceptable diagnostic and prognostic validity. The standardized procedures of PART have been investigated and described. Considering the psychometric values of PART and a short time of its performance, the test may be a useful diagnostic instrument in the assessment of premorbid level of intelligence in a group of schizophrenic patients.

  3. Mini mental Parkinson test: standardization and normative data on an Italian sample.

    Science.gov (United States)

    Costa, Alberto; Bagoj, Eriola; Monaco, Marco; Zabberoni, Silvia; De Rosa, Salvatore; Mundi, Ciro; Caltagirone, Carlo; Carlesimo, Giovanni Augusto

    2013-10-01

    The mini mental Parkinson (MMP) is a test built to overcome the limits of the mini mental state examination (MMSE) in the short-time screening of cognitive disorders in individuals with Parkinson's disease (PD). In fact, in this scale, items tapping executive functioning are included to better capture PD-related cognitive changes. Some data sustain the sensitivity and validity of the MMP in the short neuropsychological screening of these individuals. Here, we report normative data on the MMP we collected on a sample of 307 Italian healthy subjects ranging from 40 to 91 years. The results document a detrimental effect of age and an ameliorative effect of education on the MMP total performance score. We provide for correction grids for age and literacy that derive from results of the regression analyses. Moreover, we also computed equivalent scores in order to allow a direct and fast comparison between the performance on the MMP and on other psychometric measures that can be administered to the subjects.

  4. Internal consistency, reliability, and temporal stability of the Oxford Happiness Questionnaire short-form: Test-retest data over two weeks

    OpenAIRE

    MCGUCKIN, CONOR

    2006-01-01

    PUBLISHED The Oxford Happiness Questionnaire short-form is a recently developed eight-item measure of happiness. This study evaluated the internal consistency reliability and test-retest reliability of the Oxford Happiness Questionnaire short-form among 55 Northern Irish undergraduate university students who completed the measure on two occasions separated by two weeks. Internal consistency of the measure on both occasions was satisfactory at both Time 1 (alpha = .62) and Time 2 (alpha = ....

  5. Temperature effects on the magnetic properties of silicon-steel sheets using standardized toroidal frame.

    Science.gov (United States)

    Wu, Cheng-Ju; Lin, Shih-Yu; Chou, Shang-Chin; Tsai, Chia-Yun; Yen, Jia-Yush

    2014-01-01

    This study designed a detachable and standardized toroidal test frame to measure the electromagnetic characteristic of toroidal laminated silicon steel specimens. The purpose of the design was to provide the measurements with standardized and controlled environment. The device also can withstand high temperatures (25-300°C) for short time period to allow high temperature tests. The accompanying driving circuit facilitates testing for high frequency (50-5,000 Hz) and high magnetic flux (0.2-1.8 T) conditions and produces both sinusoidal and nonsinusoidal test waveforms. The thickness of the stacked laminated silicon-steel sheets must be 30~31 mm, with an internal diameter of 72 mm and an outer diameter of 90 mm. With the standardized setup, it is possible to carry out tests for toroidal specimen in high temperature and high flux operation. The test results show that there is a tendency of increased iron loss under high temperature operation. The test results with various driving waveforms also provide references to the required consideration in engineering designs.

  6. Alternate performance standard project: Interpreting the post-construction test

    International Nuclear Information System (INIS)

    Williamson, A.D.; McDonough, S.E.

    1993-01-01

    The paper describes the results of a project commissioned by the State of Florida, in cooperation with the US Environmental Protection Agency, as one portion of the Florida Radon Research Program (FRRP). The purpose of the FRRP is to provide technical support for a statewide Building Standard for Radon-Resistant Construction currently in the rulemaking process. In this case the information provides technical background for a post-construction radon test specified as a performance element of the code which accompanies the prescriptive alternative that does not incorporate active radon reduction systems

  7. Short Assessment of Health Literacy for Portuguese-speaking Adults

    Directory of Open Access Journals (Sweden)

    Daniel Apolinario

    2012-08-01

    Full Text Available OBJECTIVE: To develop and validate a short health literacy assessment tool for Portuguese-speaking adults. METHODS: The Short Assessment of Health Literacy for Portuguese-speaking Adults is an assessment tool which consists of 50 items that assess an individual's ability to correctly pronounce and understand common medical terms. We evaluated the instrument's psychometric properties in a convenience sample of 226 Brazilian older adults. Construct validity was assessed by correlating the tool scores with years of schooling, self-reported literacy, and global cognitive functioning. Discrimination validity was assessed by testing the tool's accuracy in detecting inadequate health literacy, defined as failure to fully understand standard medical prescriptions. RESULTS: Moderate to high correlations were found in the assessment of construct validity (Spearman's coefficients ranging from 0.63 to 0.76. The instrument showed adequate internal consistency (Cronbach's alpha=0.93 and adequate test-retest reliability (intraclass correlation coefficient=0.95. The area under the receiver operating characteristic curve for detection of inadequate health literacy was 0.82. A version consisting of 18 items was tested and showed similar psychometric properties. CONCLUSIONS: The instrument developed showed good validity and reliability in a sample of Brazilian older adults. It can be used in research and clinical settings for screening inadequate health literacy.

  8. A standardized procedure for eddy-current testing of stainless steel, thin-walled nuclear fuel element cladding tubes

    International Nuclear Information System (INIS)

    Barat, P.; Raj, B.; Bhattacharya, D.K.

    1982-01-01

    Thin-walled nuclear fuel cladding tubes made of AISI 316 stainless steel have been examined by eddy-current testing. Standardization of the procedures has required investigations on optimizing the test frequency, finding a method to locate a defect with respect to the probe reference end, and the use of standard defects and sequential metallography of natural defects detected by eddy-current testing, to understand the influence of the nature of defects on the impedance output signals. Test frequency and method of locating the defect were optimized by the use of standard defects made by machining in reference cladding tubes. Subsequent metallography of natural defects detected by eddy-current testing revealed mainly clusters of inclusions but also other types of defects. The effect of the distribution of inclusions along the length of the tube on the impedance output is discussed. (author)

  9. Developing Effective Physical Fitness Testing Standards for Pre Service Physical Educators

    Science.gov (United States)

    Hill, Kory; Thornburg, Roland

    2016-01-01

    Physical educators are often held to a higher standard of physical fitness. The ability to effectively convey the importance of physical fitness may depend upon the ability to appear physically fit. The ability to perform at a minimal level of proficiency on fitness tests was deemed important by the faculty of one physical education teacher…

  10. An Evaluation of the Sniffer Global Optimization Algorithm Using Standard Test Functions

    Science.gov (United States)

    Butler, Roger A. R.; Slaminka, Edward E.

    1992-03-01

    The performance of Sniffer—a new global optimization algorithm—is compared with that of Simulated Annealing. Using the number of function evaluations as a measure of efficiency, the new algorithm is shown to be significantly better at finding the global minimum of seven standard test functions. Several of the test functions used have many local minima and very steep walls surrounding the global minimum. Such functions are intended to thwart global minimization algorithms.

  11. Endocrinological Assessment Of Children With Significant Short Stature Using Radioimmunoassay Techniques

    International Nuclear Information System (INIS)

    Ghaly, Isis; Hafez, Mona; Shousha, M. A.

    2004-01-01

    This study was undertaken to determine the prevalence of clinical diagnosis in a group of children with significant short stature, height <-2.5 standard deviation below the mean for age and sex. Forty-nine children-l 8 female and 31 males-were included, mean age was 11.14 yr. (range 1.18 to 19 yr.). Clinical diagnosis, axiological measurements, thyroid profile, growth hormone, autoantibody screening for celiac disease were assessed. The patients were classified into 5 groups: Group I. familial short stature (FSS)and constitutional delay in growth and puberty (CDGP), (12%); group II. growth hormone deficiency (GHD), 54%; group III. Laron type of dwarfism (LTD) (10%); group IV. growth hormone neurosecretory disorder (GHND, 16%); group V. celiac disease (GSE, 8%). From this study the group with short normal variant (FSS-CDGP), uncommonly presents with significant short stature. Cranial CT scan should performed in any child with the diagnosis of GHD to exclude organic causes of GHD. In the group of GHND, a normal GH values to provocative tests does not guarantee sufficient GH secretion and should not be used to exclude these children from hGH treatment. Further investigations by measurement of integrated GH and IGFI may aid in the diagnosis of this disorder. Celiac disease may present only by short stature, therefore antibody screening tests should be a routine investigation for all children presented with unexplained short stature. Patient with GHD showed significant improvement of their GV SDS during treatment with hGH (p=0.021). Also children with GSE showed significant catch up growth after gluten withdrawal from the diet (p=0.029). (Authors)

  12. National and International Standardization (International Organization for Standardization and European Committee for Standardization Relevant for Sustainability in Construction

    Directory of Open Access Journals (Sweden)

    Renata Morbiducci

    2010-12-01

    Full Text Available Sustainability in construction has a short history in terms of principles, standardizations and applications. From the Brundtland Report “Our Common Future”, a new vision of the resource deficits, climate impacts and the social responsibility gave growth to the idea of sustainability also in design and construction. Consequently, in around 2000, the international and national organizations for standardization started to develop standards for the application of sustainable principles. This paper gives an overview of existing and planned standards, and examples on how to use them as a framework for the development of methods and tools for assessment.

  13. Spray Drift Reduction Evaluations of Spray Nozzles Using a Standardized Testing Protocol

    Science.gov (United States)

    2010-07-01

    Drop Size Characteristics in a Spray Using Optical Nonimaging Light-Scattering Instruments,” Annual Book of ASTM Standards, Vol. 14-02, ASTM...Test Method for Determining Liquid Drop Size Characteristics in a Spray Using Optical Non- imaging Light-Scattering Instruments 22. AGDISP Model

  14. Standard test method for determining atmospheric chloride deposition rate by wet candle method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers a wet candle device and its use in measuring atmospheric chloride deposition (amount of chloride salts deposited from the atmosphere on a given area per unit time). 1.2 Data on atmospheric chloride deposition can be useful in classifying the corrosivity of a specific area, such as an atmospheric test site. Caution must be exercised, however, to take into consideration the season because airborne chlorides vary widely between seasons. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  15. Standard Test Methods for Measurement of Electrical Performance and Spectral Response of Nonconcentrator Multijunction Photovoltaic Cells and Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 These test methods provide special techniques needed to determine the electrical performance and spectral response of two-terminal, multijunction photovoltaic (PV) devices, both cell and modules. 1.2 These test methods are modifications and extensions of the procedures for single-junction devices defined by Test Methods E948, E1021, and E1036. 1.3 These test methods do not include temperature and irradiance corrections for spectral response and current-voltage (I-V) measurements. Procedures for such corrections are available in Test Methods E948, E1021, and E1036. 1.4 These test methods may be applied to cells and modules intended for concentrator applications. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and ...

  16. Introducing Vouchers and Standardized Tests for Higher Education in Russia: Expectations and Measurements

    OpenAIRE

    Osipian, Ararat

    2008-01-01

    The reform of higher education in Russia, based on standardized tests and educational vouchers, was intended to reduce inequalities in access to higher education. The initiative with the vouchers has failed and by now is already forgotten while the national test is planned to be introduced nationwide in 2009. The national test called to replace the present corrupt system of entry examinations has experienced numerous problems so far and will likely have even more problems in the future. This ...

  17. Standard Test Method for Stress-Corrosion of Titanium Alloys by Aircraft Engine Cleaning Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method establishes a test procedure for determining the propensity of aircraft turbine engine cleaning and maintenance materials for causing stress corrosion cracking of titanium alloy parts. 1.2 The evaluation is conducted on representative titanium alloys by determining the effect of contact with cleaning and maintenance materials on tendency of prestressed titanium alloys to crack when subsequently heated to elevated temperatures. 1.3 Test conditions are based upon manufacturer's maximum recommended operating solution concentration. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see and .

  18. Standard test method for measurement of soil resistivity using the two-electrode soil box method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the equipment and a procedure for the measurement of soil resistivity, for samples removed from the ground, for use in the control of corrosion of buried structures. 1.2 Procedures allow for this test method to be used n the field or in the laboratory. 1.3 The test method procedures are for the resistivity measurement of soil samples in the saturated condition and in the as-received condition. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. Soil resistivity values are reported in ohm-centimeter. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  19. Standard Test Method for Effects of Cleaning and Chemical Maintenance Materials on Painted Aircraft Surfaces

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers determination of the effects of cleaning solutions and liquid cleaner concentrates on painted aircraft surfaces (Note 1). Streaking, discoloration, and blistering may be determined visually. Softening is determined with a series of specially prepared pencils wherein determination of the softest pencil to rupture the paint film is made. Note 1—This test method is applicable to any paint film that is exposed to cleaning materials. MIL-PRF-85285 has been selected as a basic example. When other paint finishes are used, refer to the applicable material specification for panel preparation and system curing prior to testing. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user ...

  20. Standard Test Method for Measuring Reaction Rates by Radioactivation of Uranium-238

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers procedures for measuring reaction rates by assaying a fission product (F.P.) from the fission reaction 238U(n,f)F.P. 1.2 The reaction is useful for measuring neutrons with energies from approximately 1.5 to 7 MeV and for irradiation times up to 30 to 40 years. 1.3 Equivalent fission neutron fluence rates as defined in Practice E 261 can be determined. 1.4 Detailed procedures for other fast-neutron detectors are referenced in Practice E 261. 1.5 The values stated in SI units are to be regarded as standard. No other unites of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  1. Standard Test Method for Measuring Reaction Rates by Radioactivation of Neptunium-237

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers procedures for measuring reaction rates by assaying a fission product (F.P.) from the fission reaction 237Np(n,f)F.P. 1.2 The reaction is useful for measuring neutrons with energies from approximately 0.7 to 6 MeV and for irradiation times up to 30 to 40 years. 1.3 Equivalent fission neutron fluence rates as defined in Practice E 261 can be determined. 1.4 Detailed procedures for other fast-neutron detectors are referenced in Practice E 261. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. Mercury Induced Biochemical Alterations As Oxidative Stress In Mugil Cephalus In Short Term Toxicity Test

    OpenAIRE

    J.S.I Rajkumar; Samuel Tennyson

    2013-01-01

    Mugil cephalus juveniles of size 2.5 ±0.6cm were exposed to mercury in short term chronic toxicity test through static renewal bioassay to detect the possible biochemical agent as biomarkers in aquatic pollution and in estuarine contamination as specific. Lipid peroxidation levels, glutathione S -transferase, catalase, reduced glutathione and acetylcholinesterase were studied as biochemical parameters. Increased thio-barbituric acid reactive substances levels were observed under exposur...

  3. Sweat test for cystic fibrosis: Wearable sweat sensor vs. standard laboratory test.

    Science.gov (United States)

    Choi, Dong-Hoon; Thaxton, Abigail; Jeong, In Cheol; Kim, Kain; Sosnay, Patrick R; Cutting, Garry R; Searson, Peter C

    2018-03-23

    Sweat chloride testing for diagnosis of cystic fibrosis (CF) involves sweat induction, collection and handling, and measurement in an analytical lab. We have developed a wearable sensor with an integrated salt bridge for real-time measurement of sweat chloride concentration. Here, in a proof-of-concept study, we compare the performance of the sensor to current clinical practice in CF patients and healthy subjects. Sweat was induced on both forearms of 10 individuals with CF and 10 healthy subjects using pilocarpine iontophoresis. A Macroduct sweat collection device was attached to one arm and sweat was collected for 30 min and then sent for laboratory analysis. A sensor was attached to the other arm and the chloride ion concentration monitored in real time for 30 min using a Bluetooth transceiver and smart phone app. Stable sweat chloride measurements were obtained within 15 min following sweat induction using the wearable sensor. We define the detection time as the time at which the standard deviation of the real-time chloride ion concentration remained below 2 mEq/L for 5 min. The sweat volume for sensor measurements at the detection time was 13.1 ± 11.4 μL (SD), in many cases lower than the minimum sweat volume of 15 μL for conventional testing. The mean difference between sweat chloride concentrations measured by the sensor and the conventional laboratory practice was 6.2 ± 9.5 mEq/L (SD), close to the arm-to-arm variation of about 3 mEq/L. The Pearson correlation coefficient between the two measurements was 0.97 highlighting the excellent agreement between the two methods. A wearable sensor can be used to make real-time measurements of sweat chloride within 15 min following sweat induction, requiring a small sweat volume, and with excellent agreement to standard methods. Copyright © 2018 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  4. Review of application code and standards for mechanical and piping design of HANARO fuel test loop

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. Y.

    1998-02-01

    The design and installation of the irradiation test facility for verification test of the fuel performance are very important in connection with maximization of the utilization of HANARO. HANARO fuel test loop was designed in accordance with the same code and standards of nuclear power plant because HANARO FTL will be operated the high pressure and temperature same as nuclear power plant operation conditions. The objective of this study is to confirm the propriety of application code and standards for mechanical and piping of HANARO fuel test loop and to decide the technical specification of FTL systems. (author). 18 refs., 8 tabs., 6 figs.

  5. Standard Test Method for Measuring Binocular Disparity in Transparent Parts

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the amount of binocular disparity that is induced by transparent parts such as aircraft windscreens, canopies, HUD combining glasses, visors, or goggles. This test method may be applied to parts of any size, shape, or thickness, individually or in combination, so as to determine the contribution of each transparent part to the overall binocular disparity present in the total “viewing system” being used by a human operator. 1.2 This test method represents one of several techniques that are available for measuring binocular disparity, but is the only technique that yields a quantitative figure of merit that can be related to operator visual performance. 1.3 This test method employs apparatus currently being used in the measurement of optical angular deviation under Method F 801. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not con...

  6. Testing the standard model with precision calculations of semileptonic B-decays

    Energy Technology Data Exchange (ETDEWEB)

    Turczyk, Sascha S.

    2011-01-14

    Measurements in the flavour sector are very important to test the Standard Model, since most of the free parameters are related to flavour physics. We are discussing semileptonic B-meson decays, from which an important parameter, vertical stroke V{sub cb} vertical stroke, is extracted. First we discuss higher-order non-perturbative corrections in inclusive semileptonic decays of B mesons. We identify the relevant hadronic matrix elements up to 1/m{sup 5}{sub b} and estimate them using an approximation scheme. Within this approach the e ects on the integrated rate and on kinematic moments are estimated. Similar estimates are presented for B {yields} X{sub s} + {gamma} decays. Furthermore we investigate the role of so-called ''intrinsic-charm'' operators in this decay, which appear first at order 1/m{sup 3}{sub b} in the heavy-quark expansion. We show by explicit calculation that - at scales {mu} {<=} m{sub c} - the contributions from ''intrinsic-charm'' effects can be absorbed into short-distance coefficient functions multiplying, for instance, the Darwin term. Then, the only remnant of ''intrinsic charm'' are logarithms of the form ln(m{sup 2}{sub c}/m{sup 2}{sub b}), which can be resummed by using renormalization-group techniques. As long as the dynamics at the charm quark scale is perturbative, {alpha}{sub s}(m{sub c}) << 1, this implies that no additional non-perturbative matrix elements aside from the Darwin and the spin-orbit term have to be introduced at order 1/m{sup 3}{sub b}. However, ''intrinsic charm'' leads at the next order to terms with inverse powers of the charm mass: 1/m{sup 3}{sub b} x 1/m{sup 2}{sub c}. Parametrically they complement the estimate of the potential impact of 1/m{sup 4}{sub b} contributions, which we will explore. In this context, we draw semiquantitative conclusions for the expected scale of weak annihilation in semileptonic B decays, both for its

  7. Shorts due to diagnostic leads

    International Nuclear Information System (INIS)

    Ellis, J.F.; Lubell, M.S.; Pillsbury, R.D.; Shen, S.S.; Thome, R.J.; Walstrom, P.L.

    1985-01-01

    The superconducting toroidal field coils that are being tested in the Large Coil Test Facility (LCTF) are heavily instrumented. General Electric coil, a lead wire of an internal sensor became shorted across an estimated three or four turns of the pancake winding. This short occurred during the final stages of the winding fabrication and was not accessible for repair. Resistance, voltage gradient, and transient voltage decay measurements were performed to characterize the short and the magnetic damping of the large steel bobbin and outer structural ring. The 32-gage wire causing the short was estimated to be about 10 cm long, with a resistance of 55 mΩ. As a safety measure, we decided to burn out the shorted wire at room temperature before installing the coil in LCTF. Tests were made to determine the energy needed to vaporize a small wire. Computer calculations indicated that within the voltage limits set for the coil, it was not feasible to burn out the wire by rapidly dumping the coil from a low-current dc charge-up. We accomplished the burnout by applying 800 V at 3.25 A, and 60 Hz for about 1 s. Transient voltage decay measurements made after the burnout and compared with those made before the attempt confirmed that the short had indeed been opened

  8. ['Gold standard', not 'golden standard'

    NARCIS (Netherlands)

    Claassen, J.A.H.R.

    2005-01-01

    In medical literature, both 'gold standard' and 'golden standard' are employed to describe a reference test used for comparison with a novel method. The term 'gold standard' in its current sense in medical research was coined by Rudd in 1979, in reference to the monetary gold standard. In the same

  9. ASME N511-19XX, Standard for periodic in-service testing of nuclear air treatment, heating, ventilating and air conditioning systems

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-08-01

    A draft version of the Standard is presented in this document. The Standard covers the requirements for periodic in-service testing of nuclear safety-related air treatment, heating, ventilating, and air conditioning systems in nuclear facilities. The Standard provides a basis for the development of test programs and does not include acceptance criteria, except in cases where the results of one test influence the performance of other tests. The Standard covers general inspection and test requirements, reference values, inspection and test requirements, generic tests, acceptance criteria, in-service test requirements, testing following an abnormal incident, corrective action requirements, and quality assurance. Mandatory appendices provide a visual inspection checklist and four test procedures. Non-mandatory appendices provide additional information and guidance on mounting frame pressure leak test procedure, corrective action, challenge gas substitute selection criteria, and test program development. 8 refs., 10 tabs.

  10. ASME N511-19XX, Standard for periodic in-service testing of nuclear air treatment, heating, ventilating and air conditioning systems

    International Nuclear Information System (INIS)

    1997-01-01

    A draft version of the Standard is presented in this document. The Standard covers the requirements for periodic in-service testing of nuclear safety-related air treatment, heating, ventilating, and air conditioning systems in nuclear facilities. The Standard provides a basis for the development of test programs and does not include acceptance criteria, except in cases where the results of one test influence the performance of other tests. The Standard covers general inspection and test requirements, reference values, inspection and test requirements, generic tests, acceptance criteria, in-service test requirements, testing following an abnormal incident, corrective action requirements, and quality assurance. Mandatory appendices provide a visual inspection checklist and four test procedures. Non-mandatory appendices provide additional information and guidance on mounting frame pressure leak test procedure, corrective action, challenge gas substitute selection criteria, and test program development. 8 refs., 10 tabs

  11. Research on resistance characteristics of YBCO tape under short-time DC large current impact

    Science.gov (United States)

    Zhang, Zhifeng; Yang, Jiabin; Qiu, Qingquan; Zhang, Guomin; Lin, Liangzhen

    2017-06-01

    Research of the resistance characteristics of YBCO tape under short-time DC large current impact is the foundation of the developing DC superconducting fault current limiter (SFCL) for voltage source converter-based high voltage direct current system (VSC-HVDC), which is one of the valid approaches to solve the problems of renewable energy integration. SFCL can limit DC short-circuit and enhance the interrupting capabilities of DC circuit breakers. In this paper, under short-time DC large current impacts, the resistance features of naked tape of YBCO tape are studied to find the resistance - temperature change rule and the maximum impact current. The influence of insulation for the resistance - temperature characteristics of YBCO tape is studied by comparison tests with naked tape and insulating tape in 77 K. The influence of operating temperature on the tape is also studied under subcooled liquid nitrogen condition. For the current impact security of YBCO tape, the critical current degradation and top temperature are analyzed and worked as judgment standards. The testing results is helpful for in developing SFCL in VSC-HVDC.

  12. Signal processing of data from short sample tests for the projection of conductor performance in ITER magnets

    International Nuclear Information System (INIS)

    Martovetsky, Nicolai

    2008-01-01

    Qualification of the ITER conductor is absolutely necessary. Testing large scale conductors is expensive and time-consuming. To test 3-4 m long straight samples in a bore of a split solenoid is a relatively economical way in comparison with the fabrication of a coil to be tested in a bore of a background field solenoid. However, testing short samples may give ambiguous results due to different constraints in current redistribution in the cable or other end effects which are not present in the large magnet. This paper discusses the processes taking place in the ITER conductor, conditions when conductor performance could be distorted and possible signal processing to deduce the behaviour of ITER conductors in ITER magnets from the test data

  13. Tests of local Lorentz invariance violation of gravity in the standard model extension with pulsars.

    Science.gov (United States)

    Shao, Lijing

    2014-03-21

    The standard model extension is an effective field theory introducing all possible Lorentz-violating (LV) operators to the standard model and general relativity (GR). In the pure-gravity sector of minimal standard model extension, nine coefficients describe dominant observable deviations from GR. We systematically implemented 27 tests from 13 pulsar systems to tightly constrain eight linear combinations of these coefficients with extensive Monte Carlo simulations. It constitutes the first detailed and systematic test of the pure-gravity sector of minimal standard model extension with the state-of-the-art pulsar observations. No deviation from GR was detected. The limits of LV coefficients are expressed in the canonical Sun-centered celestial-equatorial frame for the convenience of further studies. They are all improved by significant factors of tens to hundreds with existing ones. As a consequence, Einstein's equivalence principle is verified substantially further by pulsar experiments in terms of local Lorentz invariance in gravity.

  14. 30 CFR 75.601 - Short circuit protection of trailing cables.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Short circuit protection of trailing cables. 75... MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Trailing Cables § 75.601 Short circuit protection of trailing cables. [Statutory Provisions] Short circuit protection for trailing cables...

  15. The development and standardization of testing methods for genetically modified organisms and their derived products.

    Science.gov (United States)

    Zhang, Dabing; Guo, Jinchao

    2011-07-01

    As the worldwide commercialization of genetically modified organisms (GMOs) increases and consumers concern the safety of GMOs, many countries and regions are issuing labeling regulations on GMOs and their products. Analytical methods and their standardization for GM ingredients in foods and feed are essential for the implementation of labeling regulations. To date, the GMO testing methods are mainly based on the inserted DNA sequences and newly produced proteins in GMOs. This paper presents an overview of GMO testing methods as well as their standardization. © 2011 Institute of Botany, Chinese Academy of Sciences.

  16. Analysis of the qualification test standards for small radioactive material shipping packages

    International Nuclear Information System (INIS)

    McClure, J.D.

    1978-01-01

    The study compares the severity of the existing regulatory standards which are used to license radioactive material (RAM) shipping packages with the severity of transportation accidents. The basic findings of the study indicate that the present regulatory standards provide significantly higher levels of protection for surface transportation modes (truck, rail) than for RAM packages shipped by aircraft. It was also determined that crush can occur in all of the transport modes and is not presently included in existing regulations for accident conditions. Test proposals are included for the surface transport mode (truck, rail) and the air transport mode

  17. Voter Perceptions: Common Core State Standards & Tests

    Science.gov (United States)

    Achieve, Inc., 2014

    2014-01-01

    Since June 2010, 46 states and Washington DC have adopted the Common Core State Standards (CCSS)--K-12 standards in mathematics and English language arts/literacy developed through a multi-state initiative led by the National Governors Association and the Council of Chief State School Officers. Implementation of the standards is underway in all of…

  18. Performance of an extrapolation chamber in computed tomography standard beams

    International Nuclear Information System (INIS)

    Castro, Maysa C.; Silva, Natália F.; Caldas, Linda V.E.

    2017-01-01

    Among the medical uses of ionizing radiations, the computed tomography (CT) diagnostic exams are responsible for the highest dose values to the patients. The dosimetry procedure in CT scanner beams makes use of pencil ionization chambers with sensitive volume lengths of 10 cm. The aim of its calibration is to compare the values that are obtained with the instrument to be calibrated and a standard reference system. However, there is no primary standard system for this kind of radiation beam. Therefore, an extrapolation ionization chamber built at the Calibration Laboratory (LCI), was used to establish a CT primary standard. The objective of this work was to perform some characterization tests (short- and medium-term stabilities, saturation curve, polarity effect and ion collection efficiency) in the standard X-rays beams established for computed tomography at the LCI. (author)

  19. Performance of an extrapolation chamber in computed tomography standard beams

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Maysa C.; Silva, Natália F.; Caldas, Linda V.E., E-mail: mcastro@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    Among the medical uses of ionizing radiations, the computed tomography (CT) diagnostic exams are responsible for the highest dose values to the patients. The dosimetry procedure in CT scanner beams makes use of pencil ionization chambers with sensitive volume lengths of 10 cm. The aim of its calibration is to compare the values that are obtained with the instrument to be calibrated and a standard reference system. However, there is no primary standard system for this kind of radiation beam. Therefore, an extrapolation ionization chamber built at the Calibration Laboratory (LCI), was used to establish a CT primary standard. The objective of this work was to perform some characterization tests (short- and medium-term stabilities, saturation curve, polarity effect and ion collection efficiency) in the standard X-rays beams established for computed tomography at the LCI. (author)

  20. A review on test procedure, energy efficiency standards and energy labels for room air conditioners and refrigerator-freezers

    Energy Technology Data Exchange (ETDEWEB)

    Mahlia, T.M.I.; Saidur, R. [Department of Mechanical Engineering, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2010-09-15

    Air conditioners and refrigerator-freezers are major energy users in a household environment and hence efficiency improvement of these appliances can be considered as an important step to reduce their energy consumption along with environmental pollution prevention. Energy efficiency standards and labels are commonly used tools to reduce the energy uses for household appliances for many countries around the world. The first step towards adopting energy efficiency standards is to establish a test procedure for rating and testing of an appliance. It may be mentioned that an energy test procedure is the technical foundation for energy efficiency standards, energy labels, and other related programs. This paper reviews requirements and specifications of various international test standards for testing and rating of room air conditioners and refrigerators. A review on the development of the energy efficiency standards has been provided as well. Finally, energy labels that provide some useful information for identifying energy efficient products have been reviewed for these appliances. It may be stated that the review will be useful for the developing countries who wish to develop these energy savings strategies. It is also expected to be useful to revise the existing strategies for a few selected countries who already implemented these strategies earlier. (author)

  1. Acceptance test for the linear motion actuator for the scanning slit of the HIE-ISOLDE short diagnostic boxes

    CERN Document Server

    Cantero, E D; Bravin, E; Sosa, A

    2014-01-01

    We performed experimental tests to characterize the mechanical accuracy of a linear actuator designed by the company AVS for the movement of the scanning slit of the HIE-ISOLDE short diagnostic boxes. The mechanism consists of a linear actuator composed of two guiding rods and a lead screw, with a full stroke of 135 mm. A specially designed blade was mounted on the actuator and the transverse positioning of the blade was monitored with a camera-based optical system while moving the actuator at speeds of up to 10 mm/s. The repeatability of the positioning of the blade after several cycles around predefined positions was also measured. The results of the measurements and a general inspection of the device show that the proposed solution fulfils the specifications. A full prototype of short diagnostic box for the HIE-ISOLDE project can now be built for testing.

  2. Filtration: Novel Absorber Evaluation Club aims at standardized testing

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    In the past few years a number of novel absorber materials, both organic and inorganic, have appeared on the market - some claiming to achieve very large decontamination factors for metal ions, including those having radioactive isotopes. Several of these materials have been tested by individual companies in the nuclear industry and some have shown promise as decontaminants for radioactive waste streams. Unfortunately, the results obtained for the treatment of a particular waste stream cannot be applied directly to the many and diverse waste streams generated throughout the nuclear industry. A unified and standardized testing programme making use of available expertise is necessary to provide a fair and meaningful comparison. In November 1988, representatives of the United Kingdom nuclear industry agreed to form the Novel Absorber Evaluation Club to assess absorber materials and to undertake the necessary work to identify the extent and rate of adsorption of radionuclides by such materials from a set of typical reference waste streams. (author)

  3. Earthworm avoidance test for soil assessments. An alternative for acute and reproduction tests

    Energy Technology Data Exchange (ETDEWEB)

    Hund-Rinke, K.; Wiechering, H. [Fraunhofer-Inst. fuer Umweltchemie und Oekotoxikologie, Schmallenberg (Germany)

    2001-07-01

    For ecotoxicological assessments of contaminated or remediated soils pointing to the habitat function of soils for biocenoses, standardized tests with earthworms (acute test, reproduction test) are available among others. Tests used for routine applications should be sensitive and indicate impacts on test organisms after short test periods. The usually applied earthworm tests do not satisfactorily fulfil these criteria. Therefore, in the present work, a behavioural test with earthworms (test criterion: avoidance) was investigated in detail using uncontaminated, artificially contaminated and originally contaminated soils. It was demonstrated that the avoidance behaviour is primarily determined by pollutants, and not by chemical-physical soil properties. The sensitivity of the presented test reaches the sensitivity of established tests. For waste sites, a considerably higher sensitivity was determined. An avoidance behaviour of at least 80% of the worms leaving the soil to be assessed is proposed as a criterion for toxicity. (orig.)

  4. Testing for the validity of purchasing power parity theory both in the long-run and the short-run for ASEAN-5

    Science.gov (United States)

    Choji, Niri Martha; Sek, Siok Kun

    2017-11-01

    The purchasing power parity theory says that the trade rates among two nations ought to be equivalent to the proportion of the total price levels between the two nations. For more than a decade, there has been substantial interest in testing for the validity of the Purchasing Power Parity (PPP) empirically. This paper performs a series of tests to see if PPP is valid for ASEAN-5 nations for the period of 2000-2016 using monthly data. For this purpose, we conducted four different tests of stationarity, two cointegration tests (Pedroni and Westerlund), and also the VAR model. The stationarity (unit root) tests reveal that the variables are not stationary at levels however stationary at first difference. Cointegration test results did not reject the H0 of no cointegration implying the absence long-run association among the variables and results of the VAR model did not reveal a strong short-run relationship. Based on the data, we, therefore, conclude that PPP is not valid in long-and short-run for ASEAN-5 during 2000-2016.

  5. 75 FR 48728 - The Hydrostatic Testing Provision of the Portable Fire Extinguishers Standard; Extension of the...

    Science.gov (United States)

    2010-08-11

    ... Hydrostatic Testing Provision of the Portable Fire Extinguishers Standard; Extension of the Office of... the information collection requirements contained in the Hydrostatic Testing provision of the Portable... 48729

  6. Development of a New Army Standardized Physical Readiness Test: January 2012 through December 2013

    Science.gov (United States)

    2015-06-30

    children, infants, elderly, or disabled/ill persons were excluded, as were animal, in vivo, or theoretical biomechanical or engineering studies...against a single standard. This includes the current 2-mile run and push-ups. For other tests (e.g., sit ups or proposed tests such as rowing or sprints...Force PT Assessment – evaluation of (7) Predictive Fitness Tests: pushups, grip strength, grip endurance, static squat, static row , wall sit

  7. Standard Test Method for Sizing and Counting Particulate Contaminant In and On Clean Room Garments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This test method covers the determination of detachable particulate contaminant 5 m or larger, in and on the fabric of clean room garments. 1.2 This test method does not apply to nonporous fabrics such as Tyvek or Gortex. It only applies to fabrics that are porous such as cotton or polyester. 1.3 The values stated in SI units are to be regarded as the standard. The inch-pound values given in parentheses are for information only. 1.4 This test method provides not only the traditional optical microscopic analysis but also a size distribution and surface obscuration analysis for particles on a fine-textured membrane filter or in a tape lift sample. It utilizes transmitted illumination to render all particles darker than the background for gray level detection. Particles collected on opaque plates must be transferred to a suitable membrane filter. This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associat...

  8. Standard Test Method for Gravimetric Determination of Nonvolatile Residue (NVR) in Environmentally Controlled Areas for Spacecraft

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers the determination of nonvolatile residue (NVR) fallout in environmentally controlled areas used for the assembly, testing, and processing of spacecraft. 1.2 The NVR of interest is that which is deposited on sampling plate surfaces at room temperature: it is left to the user to infer the relationship between the NVR found on the sampling plate surface and that found on any other surfaces. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

  9. Short scales to assess cannabis-related problems: a review of psychometric properties

    Directory of Open Access Journals (Sweden)

    Klempova Danica

    2008-12-01

    Full Text Available Abstract Aims The purpose of this paper is to summarize the psychometric properties of four short screening scales to assess problematic forms of cannabis use: Severity of Dependence Scale (SDS, Cannabis Use Disorders Identification Test (CUDIT, Cannabis Abuse Screening Test (CAST and Problematic Use of Marijuana (PUM. Methods A systematic computer-based literature search was conducted within the databases of PubMed, PsychINFO and Addiction Abstracts. A total of 12 publications reporting measures of reliability or validity were identified: 8 concerning SDS, 2 concerning CUDIT and one concerning CAST and PUM. Studies spanned adult and adolescent samples from general and specific user populations in a number of countries worldwide. Results All screening scales tended to have moderate to high internal consistency (Cronbach's α ranging from .72 to .92. Test-retest reliability and item total correlation have been reported for SDS with acceptable results. Results of validation studies varied depending on study population and standards used for validity assessment, but generally sensitivity, specificity and predictive power are satisfactory. Standard diagnostic cut-off points that can be generalized to different populations do not exist for any scale. Conclusion Short screening scales to assess dependence and other problems related to the use of cannabis seem to be a time and cost saving opportunity to estimate overall prevalences of cannabis-related negative consequences and to identify at-risk persons prior to using more extensive diagnostic instruments. Nevertheless, further research is needed to assess the performance of the tests in different populations and in comparison to broader criteria of cannabis-related problems other than dependence.

  10. Factors That Influence Standard Automated Perimetry Test Results in Glaucoma : Test Reliability, Technician Experience, Time of Day, and Season

    NARCIS (Netherlands)

    Montolio, Francisco G. Junoy; Wesselink, Christiaan; Gordijn, Marijke; Jansonius, Nomdo M.

    2012-01-01

    PURPOSE. To determine the influence of several factors on standard automated perimetry test results in glaucoma. METHODS. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician experience,

  11. Factors that influence standard automated perimetry test results in glaucoma: Test reliability, technician experience, time of day, and season

    NARCIS (Netherlands)

    F.G.J. Montolio (Francisco G. Junoy); C. Wesselink (Christiaan); M.C.M. Gordijn (Marijke); N.M. Jansonius (Nomdo)

    2012-01-01

    textabstractPURPOSE. To determine the influence of several factors on standard automated perimetry test results in glaucoma. METHODS. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician

  12. Standardized Test Results: KEEP and Control Students. 1975-1976, Technical Report #69.

    Science.gov (United States)

    Antill, Ellen; Speidel, Gisela E.

    This report presents the results of various standardized measures administered to Kamehameha Early Education Program (KEEP) students and control students in the school year 1975-1976. In contrast to previous comparisons, KEEP employed more rigorous procedures for the selection of the control students and for the conditions of test administration.…

  13. Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Titanium

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers procedures for measuring reaction rates by the activation reactions 46Ti(n,p) 46Sc + 47Ti(n, np)46Sc. Note 1—Since the cross section for the (n,np) reaction is relatively small for energies less than 12 MeV and is not easily distinguished from that of the (n,p) reaction, this test method will refer to the (n,p) reaction only. 1.2 The reaction is useful for measuring neutrons with energies above approximately 4.4 MeV and for irradiation times up to about 250 days (for longer irradiations, see Practice E 261). 1.3 With suitable techniques, fission-neutron fluence rates above 109 cm–2·s–1 can be determined. However, in the presence of a high thermal-neutron fluence rate, 46Sc depletion should be investigated. 1.4 Detailed procedures for other fast-neutron detectors are referenced in Practice E 261. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all...

  14. Short-circuit testing of monofilar Bi-2212 coils connected in series and in parallel

    International Nuclear Information System (INIS)

    Polasek, A; Dias, R; Serra, E T; Filho, O O; Niedu, D

    2010-01-01

    Superconducting Fault Current Limiters (SCFCL's) are one of the most promising technologies for fault current limitation. In the present work, resistive SCFCL components based on Bi-2212 monofilar coils are subjected to short-circuit testing. These SCFCL components can be easily connected in series and/or in parallel by using joints and clamps. This allows a considerable flexibility to developing larger SCFCL devices, since the configuration and size of the whole device can be easily adapted to the operational conditions. The single components presented critical current (Ic) values of 240-260 A, at 77 K. Short-circuits during 40-120 ms were applied. A single component can withstand a voltage drop of 126-252 V (0.3-0.6 V/cm). Components connected in series withstand higher voltage levels, whereas parallel connection allows higher rated currents during normal operation, but the limited current is also higher. Prospective currents as high as 10-40 kA (peak value) were limited to 3-9 kA (peak value) in the first half cycle.

  15. Distribution of motor unit potential velocities in short static and prolongd dynamic contractions at low forces: Use of the within-subject's skewness and standard deviation variables

    NARCIS (Netherlands)

    Klaver-Krol, E.G.; Henriquez, N.R.; Oosterloo, Sebe J.; Klaver, P.; Bos, J.M.; Zwarts, M.J.

    2007-01-01

    Behaviour of motor unit potential (MUP) velocities in relation to (low) force and duration was investigated in biceps brachii muscle using a surface electrode array. Short static tests of 3.8 s (41 subjects) and prolonged dynamic tests (prolonged tests) of 4 min (30 subjects) were performed as

  16. Prediction of digestible and metabolizable energy content and standardized ileal amino Acid digestibility in wheat shorts and red dog for growing pigs.

    Science.gov (United States)

    Huang, Q; Piao, X S; Ren, P; Li, D F

    2012-12-01

    Two experiments were conducted to evaluate the effects of chemical composition of wheat shorts and red dog on energy and amino acid digestibility in growing pigs and to establish prediction models to estimate their digestible (DE) and metabolizable (ME) energy content and as well as their standardized ileal digestible (SID) amino acid content. For Exp. 1, sixteen diets were fed to thirty-two growing pigs according to a completely randomized design during three successive periods. The basal diet was based on corn and soybean meal while the other fifteen diets contained 28.8% wheat shorts (N = 7) or red dog (N = 8), added at the expense of corn and soybean meal. Over the three periods, each diet was fed to six pigs with each diet being fed to two pigs during each period. The apparent total tract digestibility (ATTD) of energy in wheat shorts and red dog averaged 75.1 and 87.9%. The DE values of wheat shorts and red dog averaged 13.8 MJ/kg (range 13.1 to 15.0 MJ/kg) and 15.1 MJ/kg (range 13.3 to 16.6 MJ/kg) of dry matter, respectively. For Exp. 2, twelve growing pigs were allotted to two 6×6 Latin Square Designs with six periods. Ten of the diets were formulated based on 60% wheat shorts or red dog and the remaining two diets were nitrogen-free diets based on cornstarch and sucrose. Chromic oxide (0.3%) was used as an indigestible marker in all diets. There were no differences (p>0.05) in SID values for the amino acids in wheat shorts and red dog except for lysine and methionine. Apparent ileal digestibility (AID) and SID values for lysine in different sources of wheat shorts or red dog, which averaged 78.1 and 87.8%, showed more variation than either methionine or tryptophan. A stepwise regression was performed to establish DE, ME and amino acid digestibility prediction models. Data indicated that fiber content and amino acid concentrations were good indicators to predict energy values and amino acid digestibility, respectively. The present study confirms the large

  17. Standard test method for radiochemical determination of uranium isotopes in soil by alpha spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of alpha-emitting uranium isotopes in soil. This test method describes one acceptable approach to the determination of uranium isotopes in soil. 1.2 The test method is designed to analyze 10 g of soil; however, the sample size may be varied to 50 g depending on the activity level. This test method may not be able to completely dissolve all forms of uranium in the soil matrix. Studies have indicated that the use of hydrofluoric acid to dissolve soil has resulted in lower values than results using total dissolution by fusion. 1.3 The lower limit of detection is dependent on count time, sample size, detector, background, and tracer yield. The chemical yield averaged 78 % in a single laboratory evaluation, and 66 % in an interlaboratory collaborative study. 1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, ass...

  18. LISA Pathfinder test-mass charging during galactic cosmic-ray flux short-term variations

    Science.gov (United States)

    Grimani, C.; Fabi, M.; Lobo, A.; Mateos, I.; Telloni, D.

    2015-02-01

    Metal free-floating test masses aboard the future interferometers devoted to gravitational wave detection in space are charged by galactic and solar cosmic rays with energies \\gt 100 MeV/n. This process represents one of the main sources of noise in the lowest frequency band (\\lt 10-3 Hz) of these experiments. We study here the charging of the LISA Pathfinder (LISA-PF) gold-platinum test masses due to galactic cosmic-ray (GCR) protons and helium nuclei with the Fluka Monte Carlo toolkit. Projections of the energy spectra of GCRs during the LISA-PF operations in 2015 are considered. This work was carried out on the basis of the solar activity level and solar polarity epoch expected for LISA-PF. The effects of GCR short-term variations are evaluated here for the first time. Classical Forbush decreases, GCR variations induced by the Sun rotation, and fluctuations in the LISA-PF frequency bandwidth are discussed.

  19. Standardization of serological tests for detecting anti-Trypanosoma cruzi antibodies in dogs

    Directory of Open Access Journals (Sweden)

    M. A. Lauricella

    1993-09-01

    Full Text Available This paper reports on the standardization of four serological reactions currently used in human serodiagnosis for the detection of anti-Trypanosoma cruzi antibodies in naturally and experimentally infected dogs. Indirect immunofluorescence test (IFAT and hemagglutination test (IHAT were standardized, and complement fixation test (CFT and direct agglutination test (DAT were used for diagnostic confirmation. Four hundred and eighty one mongrel dogs that were studied by xenodiagnosis were used: (1 parasitemic dogs of two localities of endemic area (EA of Santiago del Estero province in Argentina (n = 134; (2 non-parasitemic dogs of the same area (n = 285; (3 dogs experimentally infected with T. cruzi in the patent period (n = 6; (4 non-infected dogs (n = 56 which were born in the city of Buenos Aires (BA, one non-EA for Chagas' disease. For IFAT, parasitemic dogs EA showed 95% of reactive sera. Non parasitemic dogs EA showed 77% of non reactive sera. None sera from BA were reactive for dilutions higher than four. For IHAT, 84% of sera of parasitemic dogs EA showed serological reactivity and among non parasitemic dogs BA, 61% were non reactive, while the remainder showed at most titres of 1/16. The cut-off titres for IFAT and IHAT were 1/16 and 1/32 respectively, and for CFT and DAT 1/1 and 1/128 respectively. Sensitivity for IFAT, IHAT, CF and DAT were 95%, 84%, 97% and 95% respectively.

  20. Current research efforts at JILA to test the equivalence principle at short ranges

    International Nuclear Information System (INIS)

    Faller, J.E.; Niebauer, T.M.; McHugh, M.P.; Van Baak, D.A.

    1988-01-01

    We are presently engaged in three different experiments to search for a possible breakdown of the equivalence principle at short ranges. The first of these experiments, which has been completed, is our so-called Galilean test in which the differential free-fall of two objects of differing composition was measured using laser interferometry. We observed that the differential acceleration of two test bodies was less than 5 parts in 10 billion. This experiment set new limits on a suggested baryon dependent ''Fifth Force'' at ranges longer than 1 km. With a second experiment, we are investigating substance dependent interactions primarily for ranges up to 10 meters using a fluid supported torsion balance; this apparatus has been built and is now undergoing laboratory tests. Finally, a proposal has been made to measure the gravitational signal associated with the changing water level at a large pumped storage facility in Ludington, Michigan. Measuring the gravitational signal above and below the pond will yield the value of the gravitational constant, G, at ranges from 10-100 m. These measurements will serve as an independent check on other geophysical measurements of G

  1. Standard test method for uranium analysis in natural and waste water by X-ray fluorescence

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This test method applies for the determination of trace uranium content in waste water. It covers concentrations of U between 0.05 mg/L and 2 mg/L. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. MET Standards for Electro-Technical Officers

    Directory of Open Access Journals (Sweden)

    Janusz Mindykowski

    2014-12-01

    Full Text Available The paper deals with one of the most important changes in the STCW 1978 as amended in 2010 Convention, from the point of view of the watchkeeping officers responsible for control, maintenance, diagnostic and repair of electrical and electronic installations on board of ships. Some reasons, why the MET Standards for Electro-Technical had to be developed and implemented are shortly analyzed and described. A legislative way towards and a short description of the minimum standards competence for ETO are presented. Next, new tools supporting ETO’s standards implementation are appointed. Finally, the future works as well as the concluding remarks concerning discussed issue are formulated and commented on.

  3. Validity and Reliability of Baseline Testing in a Standardized Environment.

    Science.gov (United States)

    Higgins, Kathryn L; Caze, Todd; Maerlender, Arthur

    2017-08-11

    The Immediate Postconcussion Assessment and Cognitive Testing (ImPACT) is a computerized neuropsychological test battery commonly used to determine cognitive recovery from concussion based on comparing post-injury scores to baseline scores. This model is based on the premise that ImPACT baseline test scores are a valid and reliable measure of optimal cognitive function at baseline. Growing evidence suggests that this premise may not be accurate and a large contributor to invalid and unreliable baseline test scores may be the protocol and environment in which baseline tests are administered. This study examined the effects of a standardized environment and administration protocol on the reliability and performance validity of athletes' baseline test scores on ImPACT by comparing scores obtained in two different group-testing settings. Three hundred-sixty one Division 1 cohort-matched collegiate athletes' baseline data were assessed using a variety of indicators of potential performance invalidity; internal reliability was also examined. Thirty-one to thirty-nine percent of the baseline cases had at least one indicator of low performance validity, but there were no significant differences in validity indicators based on environment in which the testing was conducted. Internal consistency reliability scores were in the acceptable to good range, with no significant differences between administration conditions. These results suggest that athletes may be reliably performing at levels lower than their best effort would produce. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  4. Factors that influence standard automated perimetry test results in glaucoma: test reliability, technician experience, time of day, and season.

    Science.gov (United States)

    Junoy Montolio, Francisco G; Wesselink, Christiaan; Gordijn, Marijke; Jansonius, Nomdo M

    2012-10-09

    To determine the influence of several factors on standard automated perimetry test results in glaucoma. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician experience, time of day, and season on the mean deviation (MD) was determined by performing linear regression analysis of MD against time on a series of visual fields and subsequently performing a multiple linear regression analysis with the MD residuals as dependent variable and the factors mentioned above as independent variables. Analyses were performed with and without adjustment for the test reliability (fixation losses and false-positive and false-negative answers) and with and without stratification according to disease stage (baseline MD). Mean follow-up was 9.4 years, with on average 10.8 tests per patient. Technician experience, time of day, and season were associated with the MD. Approximately 0.2 dB lower MD values were found for inexperienced technicians (P Technician experience, time of day, season, and the percentage of false-positive answers have a significant influence on the MD of standard automated perimetry.

  5. What Is the Role and Importance of the Revised AERA, APA, NCME "Standards for Educational and Psychological Testing"?

    Science.gov (United States)

    Plake, Barbara S.; Wise, Lauress L.

    2014-01-01

    With the 2014 publication of the 5th revision of the "Standards for Educational and Psychological Testing," the cochairs of the Joint Committee for the revision process were asked to consider the role and importance of the "Standards" for the educational testing community, and in particular for members of the National Council…

  6. Test Standard Revision Update: JESD57, "Procedures for the Measurement of Single-Event Effects in Semiconductor Devices from Heavy-Ion Irradiation"

    Science.gov (United States)

    Lauenstein, Jean-Marie

    2015-01-01

    The JEDEC JESD57 test standard, Procedures for the Measurement of Single-Event Effects in Semiconductor Devices from Heavy-Ion Irradiation, is undergoing its first revision since 1996. In this talk, we place this test standard into context with other relevant radiation test standards to show its importance for single-event effect radiation testing for space applications. We show the range of industry, government, and end-user party involvement in the revision. Finally, we highlight some of the key changes being made and discuss the trade-space in which setting standards must be made to be both useful and broadly adopted.

  7. Standard Guide for On-Site Inspection and Verification of Operation of Solar Domestic Hot Water Systems

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1987-01-01

    1.1 This guide covers procedures and test methods for conducting an on-site inspection and acceptance test of an installed domestic hot water system (DHW) using flat plate, concentrating-type collectors or tank absorber systems. 1.2 It is intended as a simple and economical acceptance test to be performed by the system installer or an independent tester to verify that critical components of the system are functioning and to acquire baseline data reflecting overall short term system heat output. 1.3 This guide is not intended to generate accurate measurements of system performance (see ASHRAE standard 95-1981 for a laboratory test) or thermal efficiency. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine th...

  8. Evaluation of short-term psychological functions in opiate addicts after ablating the nucleus accumbens via stereotactic surgery.

    Science.gov (United States)

    He, Fei; Guan, Hao; Zhao, Zhijing; Miao, Xinfang; Zhou, Qin; Li, Lihong; Huang, Dongmei; Liu, Anheng; Miao, Danmin

    2008-01-01

    To investigate the short-term psychological function of opiate addicts who have undergone ablative stereotactic surgery targeting the nucleus accumbens (NAc) for alleviating opiate drug psychological dependence. The psychological functional status of 14 opiate addicts was assessed by standardized psychological tests both before and approximately 3 months after stereotactic surgery. Standardized tests included the Wechsler Adult Intelligence Scale-Revised Chinese (WAIS-RC), the Clinical Memory Scale of Chinese (CMS), the Eysenck Personality Questionnaire (EPQ) and the Symptom Checklist 90 (SCL-90). The evaluation of psychological dimensions included intelligence, memory, personality characteristics and mental health symptoms. Compared with the preoperative state, there was no statistically significant difference in full-scale intelligence quotient (IQ) postoperatively, but without Bonferroni correction a significant decline by 13.55% (p memory quotient (MQ) of CMS demonstrated a significant decline of 10.65% (p increase (p intelligence measures were not changed significantly, their short-term memory and attention appeared to decline postoperatively. In addition, there was a trend towards change in some personality characteristics postoperatively. The postoperative mental health levels of the patients increased, indicating a trend towards improvement. Stereotactic ablation of the NAc in opiate addicts may be associated with short-term negative psychological functions. Advisement regarding the safety of the new surgical modality and recommendations for further investigation are necessary. Copyright 2008 S. Karger AG, Basel.

  9. Formulation of a candidate glass for use as an acceptance test standard material

    International Nuclear Information System (INIS)

    Ebert, W.L.; Strachan, D.M.; Wolf, S.F.

    1998-04-01

    In this report, the authors discuss the formulation of a glass that will be used in a laboratory testing program designed to measure the precision of test methods identified in the privatization contracts for the immobilization of Hanford low-activity wastes. Tests will be conducted with that glass to measure the reproducibility of tests and analyses that must be performed by glass producers as a part of the product acceptance procedure. Test results will be used to determine if the contractually required tests and analyses are adequate for evaluating the acceptability of likely immobilized low-activity waste (ILAW) products. They will also be used to evaluate if the glass designed for use in these tests can be used as an analytical standard test material for verifying results reported by vendors for tests withg ILAW products. The results of those tests and analyses will be presented in a separate report. The purpose of this report is to document the strategy used to formulate the glass to be used in the testing program. The low-activity waste reference glass LRM that will be used in the testing program was formulated to be compositionally similar to ILAW products to be made with wastes from Hanford. Since the ILAW product compositions have not been disclosed by the vendors participating in the Hanford privatization project, the composition of LRM was formulated based on simulated Hanford waste stream and amounts of added glass forming chemicals typical for vitrified waste forms. The major components are 54 mass % SiO 2 , 20 mass % Na 2 O, 10 mass % Al 2 O 3 , 8 mass % B 2 O 3 , and 1.5 mass % K 2 O. Small amounts of other chemicals not present in Hanford wastes were also included in the glass, since they may be included as chemical additives in ILAW products. This was done so that the use of LRM as a composition standard could be evaluated. Radionuclides were not included in LRM because a nonradioactive material was desired

  10. Geopathic stress zones: short-term effects on work performance and well-being?

    Science.gov (United States)

    Augner, Christoph; Hacker, Gerhard W; Jekel, Ilse

    2010-06-01

    The aim of the study was to evaluate whether two different locations in the same room as tested by dowsers ("geopathic stress zone" [GSZ] versus "more neutral zone" [NZ]) would show significant short-term effects on work performance and well-being. It was also tested whether a device reported to "neutralize" GSZ would influence results obtained with the specific setup used in this study. This was a blinded, randomized, short-term laboratory experiment using a within-subject design. The study was conducted in the laboratory of the Research Institute for Frontier Questions of Medicine and Biotechnology at Salzburg Federal Hospital. The subjects were 26 persons, aged 20-57. Participants had to accomplish reaction tasks during three different conditions: GSZ, NZ, and GSZ with a device reported to "neutralize" GSZ. These conditions were counterbalanced into six different sequences and randomized to the subjects. At the end of each condition, a standardized well-being questionnaire had to be completed. Dependent variables were reactive stress tolerance (reaction time, timely right answers, right answers, false answers, left out) and well-being (described by six adjectives). No location-dependent effects on performance during reactive stress tolerance test were seen. For well-being, analysis of variance revealed a trend (p = 0.07) and showed significantly poorer well-being during the GSZ condition compared to NZ (p = 0.01). This study shows that well-being can be location dependent and that this might be caused by a so-called GSZ. However, in our short-term experiment, factors of work performance tested remained unaffected.

  11. Dustiness test of nanopowders using a standard rotating drum with a modified sampling train

    International Nuclear Information System (INIS)

    Tsai, Chuen-Jinn; Wu, Chien-Hsien; Leu, Ming-Long; Chen, Sheng-Chieh; Huang, Cheng-Yu; Tsai, Perng-Jy; Ko, Fu-Hsiang

    2009-01-01

    The standard rotating drum tester was used to determine the dustiness of two nanopowders, nano-TiO 2 and fine ZnO, in standard 1-min tests. Then, the sampling train was modified to determine the number and mass distributions of the generated particles in the respirable size range using a Scanning Mobility Particle Sizer (SMPS), an Aerodynamic Particle Sizer (APS) and a Multi-orifice Uniform Deposit Impactor (MOUDI) in the 30-min tests. It was found that very few particles below 100 nm were generated and the released rate of particles decreased with increasing rotation time for both nanopowders in the 30-min tests. Due to the fluffy structure of the released TiO 2 agglomerated particles, the mass distributions measured by the MOUDI showed large differences with those determined by the APS assuming the apparent bulk densities of the powders. The differences were small for the ZnO agglomerates, which were more compact than the TiO 2 agglomerates.

  12. Evaluation of the Standard Setting on the 2005 Grade 12 National Assessment of Educational Progress Mathematics Test

    Science.gov (United States)

    Sireci, Stephen G.; Hauger, Jeffrey B.; Wells, Craig S.; Shea, Christine; Zenisky, April L.

    2009-01-01

    The National Assessment Governing Board used a new method to set achievement level standards on the 2005 Grade 12 NAEP Math test. In this article, we summarize our independent evaluation of the process used to set these standards. The evaluation data included observations of the standard-setting meeting, observations of advisory committee meetings…

  13. DCC DIFFUSE Standards Frameworks: A Standards Path through the Curation Lifecycle

    Directory of Open Access Journals (Sweden)

    Sarah Higgins

    2009-10-01

    Full Text Available Normal 0 false false false MicrosoftInternetExplorer4 DCC DIFFUSE Standards Frameworks aims to offer domain specific advice on standards relevant to digital preservation and curation, to help curators identify which standards they should be using and where they can be appropriately implemented, to ensure authoritative digital material. The Project uses the DCC Curation Lifecycle Model and Web 2.0 technology, to visually present standards frameworks for a number of disciplines. The Digital Curation Centre (DCC is actively working with a different relevant organisations to present searchable frameworks of standards, for a number of domains. These include digital repositories, records management, the geo-information sector, archives and the museum sector. Other domains, such as e-science, will shortly be investigated.

  14. Reliability, Validity, and Minimal Detectable Change of Balance Evaluation Systems Test and Its Short Versions in Older Cancer Survivors: A Pilot Study.

    Science.gov (United States)

    Huang, Min H; Miller, Kara; Smith, Kristin; Fredrickson, Kayle; Shilling, Tracy

    2016-01-01

    Cancer is primarily a disease of older adults. About 77% of all cancers are diagnosed in persons aged 55 years and older. Cancer and its treatment can cause diverse sequelae impacting body systems underlying balance control. No study has examined the psychometric properties of balance assessment tools in older cancer survivors, presenting a significant challenge in the selection of outcome measures for clinicians treating this fast-growing population. This study aimed to determine the reliability, validity, and minimal detectable change (MDC) of the Balance Evaluation System Test (BESTest), Mini-Balance Evaluation Systems Test (Mini-BESTest), and Brief-Balance Evaluation Systems Test (Brief-BESTest) in community-dwelling older cancer survivors. This study was a cross-sectional design. Twenty breast and 8 prostate cancer survivors participated [age (SD) = 68.4 (8.13) years]. The BESTest and Activity-specific Balance Confidence (ABC) Scale were administered during the first session. Scores of Mini-BESTest and Brief-BESTest were extracted on the basis of the scores of BESTest. The BESTest was repeated within 1 to 2 weeks by the same rater to determine the test-retest reliability. For the analysis of the inter-rater reliability, 21 participants were randomly selected to be evaluated by 2 raters. A primary rater administered the test. The 2 raters independently and concurrently scored the performance of the participants. Each rater recorded the ratings separately on the scoring sheet. No discussion among the raters was allowed throughout the testing. Intraclass correlation coefficients (ICCs), standard error of measurement, minimal detectable change (MDC), and Bland-Altman plots were calculated. Concurrent validity of these balance tests with the ABC Scale was examined using the Spearman correlation. The BESTest, Mini-BESTest, and Brief-BESTest had high test-retest (ICC = 0.90-0.94) and interrater reliability (ICC = 0.86-0.96), small standard error of measurement (0

  15. A data base and a standard material for use in acceptance testing of low-activity waste products

    International Nuclear Information System (INIS)

    Wolf, S.F.; Ebert, W.L.; Luo, J.S.; Strachan, D.M.

    1998-04-01

    The authors have conducted replicate dissolution tests following the product consistency test (PCT) procedure to measure the mean and standard deviation of the solution concentrations of B, Na, and Si at various combinations of temperature, duration, and glass/water mass ratio. Tests were conducted with a glass formulated to be compositionally similar to low-activity waste products anticipated for Hanford to evaluate the adequacy of test methods that have been designated in privatization contracts for use in product acceptance. An important finding from this set of tests is that the solution concentrations generated in tests at 20 C will likely be too low to measure the dissolution rates of waste products reliably. Based on these results, the authors recommend that the acceptance test be conducted at 40 C. Tests at 40 C generated higher solution concentrations, were more easily conducted, and the measured rates were easily related to those at 20 C. Replicate measurements of other glass properties were made to evaluate the possible use of LRM-1 as a standard material. These include its composition, homogeneity, density, compressive strength, the Na leachability index with the ANSI/ANS 16.1 leach test, and if the glass is characteristically hazardous with the toxicity characteristic leach procedure. The values of these properties were within the acceptable limits identified for Hanford low-activity waste products. The reproducibility of replicate tests and analyses indicates that the glass would be a suitable standard material

  16. Standard Test Methods for Solar Energy Transmittance and Reflectance (Terrestrial) of Sheet Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1971-01-01

    1.1 These test methods cover the measurement of solar energy transmittance and reflectance (terrestrial) of materials in sheet form. Method A, using a spectrophotometer, is applicable for both transmittance and reflectance and is the referee method. Method B is applicable only for measurement of transmittance using a pyranometer in an enclosure and the sun as the energy source. Specimens for Method A are limited in size by the geometry of the spectrophotometer while Method B requires a specimen 0.61 m2 (2 ft2). For the materials studied by the drafting task group, both test methods give essentially equivalent results. 1.2 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  17. Testing of adsorbents used in nuclear power plant air cleaning systems using the open-quotes Newclose quotes standards

    International Nuclear Information System (INIS)

    Freeman, W.P.

    1993-01-01

    Ever since the publication of the NRC Information Notice No. 87-32: Deficiencies in the Testing of Nuclear-Grade Activated Charcoal, nuclear power facilities in the US have struggled in their efforts to open-quotes...review the information for applicability to their facilities and consider action, if appropriate ...close quotes as stated in the notice. The encouragement of resident NRC inspectors at some nuclear power facilities has prompted a variety of responses ranging from no change at all in testing requirements to contemplated changes in plant technical specifications. This confusion is the result of a couple factors. The first factor is the lack of a current revision to NRC Regulatory Guide 1.52, the basic document used in nuclear power plant technical specifications for the testing of engineered-safety feature (ESF) post accident air cleaning systems. The second factor is the standards that have been written since the last revision of Reg. Guide 1.52 which include two revision of ANSI N509 and N510, two revisions of RDT M16-1T, two version of ASTM D3803, two versions of ASTM D4069, and three versions of an SME code AG-1. Few of the standards and codes listed above are commensurate with each other and, thus, present a nearly insolvable maze to the HVAC engineer asked to upgrade adsorbent testing requirements following the standards. This paper describes the authors experience with a number of nuclear power facilities in their efforts to meet the requirements of the new standards of testing adsorbents from nuclear power plant air cleaning systems. The existing standards are discussed in light of the current state of the art for adsorbent testing of adsorbent media from nuclear air treatment systems. Test results are presented showing the impact of new test requirements on acceptance criteria when compared to the old test requirements and recommendations are offered for solution of this testing problem in the future. 12 refs., 5 tabs

  18. Lyral has been included in the patch test standard series in Germany.

    Science.gov (United States)

    Geier, Johannes; Brasch, Jochen; Schnuch, Axel; Lessmann, Holger; Pirker, Claudia; Frosch, Peter J

    2002-05-01

    Lyral 5% pet. was tested in 3245 consecutive patch test patients in 20 departments of dermatology in order (i) to check the diagnostic quality of this patch test preparation, (ii) to examine concomitant reactions to Lyral and fragrance mix (FM), and (iii) to assess the frequency of contact allergy to Lyral in an unselected patch test population of German dermatological clinics. 62 patients reacted to Lyral, i.e. 1.9%. One third of the positive reactions were + + and + + +. The reaction index was 0.27. Thus, the test preparation can be regarded a good diagnostic tool. Lyral and fragrance mix (FM) were tested in parallel in 3185 patients. Of these, 300 (9.4%) reacted to FM, and 59 (1.9%) to Lyral. In 40 patients, positive reactions to both occurred, which is 13.3% of those reacting to FM, and 67.8% of those reacting to Lyral. So the concordance of positive test reactions to Lyral and FM was only slight. Based on these results, the German Contact Dermatitis Research Group (DKG) decided to add Lyral 5% pet. to the standard series.

  19. The false sero-negativity of brucella standard agglutination test: Prozone phenomenon

    Directory of Open Access Journals (Sweden)

    İrfan Binici

    2011-12-01

    Full Text Available Objectives: We aimed to assess prozone phenomenon that is quite rare and causes false negativity in serological diagnosisof brucellosis with standard dilution titers.Materials and methods: In this study the tests of four cases that have false negative serological results were evaluated.Blood cultures were obtained from all cases while cerebrospinal fluid cultures were studied in the two cases. Standardagglutination test (SAT and Coombs test were performed to all patients.Results: SAT and Coombs test was negative in titers up to 1/640 in all cases. The SAT and Coombs tests in cerebrospinalfluid (CSF of the two cases with neurobrucellosis diagnosis were negative, as well. Since the clinical and laboratoryfindings suggested the brucellosis, the serums were restudied by diluting up to 1/10240 titer and we saw that the first3 cases became positive at a titer of 1/1280. The fourth case remained negative and therefore, we applied high dilutionCoombs test. This time the test gave a positive result at 1/10240 titer beginning from 1/2560 titer. B.melitensis wasisolated from two cases.Conclusion: SAT and Coombs’ test must be diluted to titers 1/2560 or more in order to exclude false sero-negativity incases with clinical and laboratory findings suggesting brucellosis. J Microbiol Infect Dis 2011; 1(3:110-113

  20. Performance Tests of a Short Faraday Cup Designed for HIE-ISOLDE

    CERN Document Server

    Cantero, E; Bravin, E; Fraser, M; Lanaia, D; Sosa, A; Voulot, D

    2013-01-01

    The On-Line Isotope Mass Separator (ISOLDE) facility at CERN is being upgraded in order to deliver higher energy and intensity radioactive beams. The final setup will consist in replacing the energy variable part of the normal conducting REX post-accelerator with superconducting cavities. In order to preserve the beam emittance, the drift space between the cryomodules housing these cavities has been kept to a minimum. As a consequence, the longitudinal space available for beam diagnostics is severely limited in the inter-cryomodule regions. A Faraday cup (FC) will be installed to measure beam currents, and due to the tight spatial constraints, its length is much smaller than usual. This poses a great challenge when trying to avoid the escape of ion-induced secondary electrons, which would falsify the current measurement. Two prototypes of such a short FC have therefore been tested at REX-ISOLDE using several beam intensities and energies, with the aim of determining its accuracy. In this paper the experimenta...

  1. The resident-intruder paradigm : a standardized test for aggression, violence and social stress

    NARCIS (Netherlands)

    Koolhaas, Jacob; Coppens, Caroline M.; de Boer, Sietse F.; Buwalda, Bauke; Meerlo, Peter; Timmermans, Paul J. A.

    2013-01-01

    This video publication explains in detail the experimental protocol of the resident-intruder paradigm in rats. This test is a standardized method to measure offensive aggression and defensive behavior in a semi natural setting. The most important behavioral elements performed by the resident and the

  2. Design standards for experimental and field studies to evaluate diagnostic accuracy of tests for infectious diseases in aquatic animals.

    Science.gov (United States)

    Laurin, E; Thakur, K K; Gardner, I A; Hick, P; Moody, N J G; Crane, M S J; Ernst, I

    2018-05-01

    Design and reporting quality of diagnostic accuracy studies (DAS) are important metrics for assessing utility of tests used in animal and human health. Following standards for designing DAS will assist in appropriate test selection for specific testing purposes and minimize the risk of reporting biased sensitivity and specificity estimates. To examine the benefits of recommending standards, design information from published DAS literature was assessed for 10 finfish, seven mollusc, nine crustacean and two amphibian diseases listed in the 2017 OIE Manual of Diagnostic Tests for Aquatic Animals. Of the 56 DAS identified, 41 were based on field testing, eight on experimental challenge studies and seven on both. Also, we adapted human and terrestrial-animal standards and guidelines for DAS structure for use in aquatic animal diagnostic research. Through this process, we identified and addressed important metrics for consideration at the design phase: study purpose, targeted disease state, selection of appropriate samples and specimens, laboratory analytical methods, statistical methods and data interpretation. These recommended design standards for DAS are presented as a checklist including risk-of-failure points and actions to mitigate bias at each critical step. Adherence to standards when designing DAS will also facilitate future systematic review and meta-analyses of DAS research literature. © 2018 John Wiley & Sons Ltd.

  3. Testing of x-ray microtomography systems using a traceable geometrical standard

    International Nuclear Information System (INIS)

    Carmignato, S; Dreossi, D; Mancini, L; Tromba, G; Marinello, F; Savio, E

    2009-01-01

    X-ray computed microtomography is an interesting imaging technique for many applications, and is also very promising in the field of coordinate metrology at the micro scale. The main advantage with respect to traditional tactile-probing or optical coordinate measurement systems is that x-ray tomography can acquire dimensional and geometrical data for both inner and outer surfaces, without accessibility restrictions. However, there are no accepted test procedures available so far and measurement uncertainty is unknown in many cases, due to complex and numerous error sources. The paper presents the first results of a test procedure implemented for determining the errors of indication for length measurements of x-ray microtomography systems, using a new reference standard featuring a regular array of inner and outer cylindrical shapes. The developed test method allows the determination of specific characteristics of x-ray microtomography systems and can be used for the correction of systematic errors

  4. Standard for baseline water-well testing for coalbed methane/natural gas in coal operations

    International Nuclear Information System (INIS)

    2006-04-01

    Interest in developing coalbed methane (CBM) is increasing with the decline of conventional natural gas reserves. In Alberta, where CBM is in the early stages of development, the drilling, production and operational rules for CBM are the same as those that apply to natural gas. The government of Alberta is presently examining the rules and regulations that apply to CBM to determine if they are appropriate for responsible development and balanced with environmental protection. CBM development has the potential to affect water aquifers and water supply. As such, a new standard has been developed by Alberta Environment in collaboration with the Alberta Energy and Utilities Board which requires that companies involved in the development of shallow CBM must offer to test rural Albertan's water wells prior to drilling. The companies will submit baseline groundwater data to both Alberta Environment and the landowner. The broader application of groundwater testing will also support Alberta Environment's objective of mapping all groundwater resources in the province. This new standard will help achieve continued protection of provincial groundwater resources and Albertan's groundwater supplies. It will also facilitate responsible CBM development and the government's Water for Life strategy. This document explained the protocols for testing, sampling and analyzing groundwater. The standard provides scientific information to support achievement of the outcomes as well as a regulatory basis for water well testing and baseline data collection prior to CBM development. If a landowner registers a complaint regarding a perceived change in well water quantity and quality after CBM development, then the developers must retest the water well to address the landowner's concerns. The tests evaluate water well capacity, water quality, routine potability and analysis for water quality parameters, including major ionic constituents, bacteriological analysis and presence or absence of gas

  5. Use of cardio-diagnostics of D&K-TEST for individualizations of training process of skilled short track speed skaters high qualification

    Directory of Open Access Journals (Sweden)

    Kygayevskiy S.A.

    2009-10-01

    Full Text Available In the article possibilities of individualization of training process of short track speed skaters high qualification are resulted on the basis of influence of application of loadings of different orientation on the indexes of cardio-diagnostics of D&K-TEST. The influences of loadings of different physiological and metabolic orientation given about efficiency are resulted on the level of functional preparedness of short track speed skaters of high qualification.

  6. Space and Missile Systems Center Standard: Test Requirements for Launch, Upper-Stage and Space Vehicles

    Science.gov (United States)

    2014-09-05

    Aviation Blvd. El Segundo, CA 90245 4. This standard has been approved for use on all Space and Missile Systems Center/Air Force Program...140 Satellite Hardness and Survivability; Testing Rationale for Electronic Upset and Burnout Effects 30. JANNAF-GL-2012-01-RO Test and Evaluation...vehicle, subsystem, and unit lev- els . Acceptance testing shall be conducted on all subsequent flight items. The protoqualification strategy shall require

  7. Standard review plan for the review and evaluation of emergency plans for research and test reactors

    International Nuclear Information System (INIS)

    1983-10-01

    This document provides a Standard Review Plan to assure that complete and uniform reviews are made of research and test reactor radiological emergency plans. The report is organized under ten planning standards which correspond to the guidance criteria in American National Standard ANSI/ANS 15.16 - 1982 as endorsed by Revision 1 to Regulatory Guide 2.6. The applicability of the items under each planning standard is indicated by subdivisions of the steady-state thermal power levels at which the reactors are licensed to operate. Standard emergency classes and example action levels for research and test reactors which should initiate these classes are given in an Appendix. The content of the emergency plan is as follows: the emergency plan addresses the necessary provisions for coping with radiological emergencies. Activation of the emergency plan is in response to the emergency action levels. In addition to addressing those severe emergencies that will fall within one of the standard emergency classes, the plan also discusses the necessary provisions to deal with radiological emergencies of lesser severity that can occur within the operations boundary. The emergency plan allows for emergency personnel to deviate from actions described in the plan for unusual or unanticipated conditions

  8. Comparison between Genetic Algorithms and Particle Swarm Optimization Methods on Standard Test Functions and Machine Design

    DEFF Research Database (Denmark)

    Nica, Florin Valentin Traian; Ritchie, Ewen; Leban, Krisztina Monika

    2013-01-01

    , genetic algorithm and particle swarm are shortly presented in this paper. These two algorithms are tested to determine their performance on five different benchmark test functions. The algorithms are tested based on three requirements: precision of the result, number of iterations and calculation time....... Both algorithms are also tested on an analytical design process of a Transverse Flux Permanent Magnet Generator to observe their performances in an electrical machine design application.......Nowadays the requirements imposed by the industry and economy ask for better quality and performance while the price must be maintained in the same range. To achieve this goal optimization must be introduced in the design process. Two of the best known optimization algorithms for machine design...

  9. Measuring the Outcome of At-Risk Students on Biology Standardized Tests When Using Different Instructional Strategies

    Science.gov (United States)

    Burns, Dana

    Over the last two decades, online education has become a popular concept in universities as well as K-12 education. This generation of students has grown up using technology and has shown interest in incorporating technology into their learning. The idea of using technology in the classroom to enhance student learning and create higher achievement has become necessary for administrators, teachers, and policymakers. Although online education is a popular topic, there has been minimal research on the effectiveness of online and blended learning strategies compared to the student learning in a traditional K-12 classroom setting. The purpose of this study was to investigate differences in standardized test scores from the Biology End of Course exam when at-risk students completed the course using three different educational models: online format, blended learning, and traditional face-to-face learning. Data was collected from over 1,000 students over a five year time period. Correlation analyzed data from standardized tests scores of eighth grade students was used to define students as "at-risk" for failing high school courses. The results indicated a high correlation between eighth grade standardized test scores and Biology End of Course exam scores. These students were deemed "at-risk" for failing high school courses. Standardized test scores were measured for the at-risk students when those students completed Biology in the different models of learning. Results indicated significant differences existed among the learning models. Students had the highest test scores when completing Biology in the traditional face-to-face model. Further evaluation of subgroup populations indicated statistical differences in learning models for African-American populations, female students, and for male students.

  10. Internal short circuit and accelerated rate calorimetry tests of lithium-ion cells: Considerations for methane-air intrinsic safety and explosion proof/flameproof protection methods.

    Science.gov (United States)

    Dubaniewicz, Thomas H; DuCarme, Joseph P

    2016-09-01

    Researchers with the National Institute for Occupational Safety and Health (NIOSH) studied the potential for lithium-ion cell thermal runaway from an internal short circuit in equipment for use in underground coal mines. In this third phase of the study, researchers compared plastic wedge crush-induced internal short circuit tests of selected lithium-ion cells within methane (CH 4 )-air mixtures with accelerated rate calorimetry tests of similar cells. Plastic wedge crush test results with metal oxide lithium-ion cells extracted from intrinsically safe evaluated equipment were mixed, with one cell model igniting the chamber atmosphere while another cell model did not. The two cells models exhibited different internal short circuit behaviors. A lithium iron phosphate (LiFePO 4 ) cell model was tolerant to crush-induced internal short circuits within CH 4 -air, tested under manufacturer recommended charging conditions. Accelerating rate calorimetry tests with similar cells within a nitrogen purged 353-mL chamber produced ignitions that exceeded explosion proof and flameproof enclosure minimum internal pressure design criteria. Ignition pressures within a 20-L chamber with 6.5% CH 4 -air were relatively low, with much larger head space volume and less adiabatic test conditions. The literature indicates that sizeable lithium thionyl chloride (LiSOCl 2 ) primary (non rechargeable) cell ignitions can be especially violent and toxic. Because ignition of an explosive atmosphere is expected within explosion proof or flameproof enclosures, there is a need to consider the potential for an internal explosive atmosphere ignition in combination with a lithium or lithium-ion battery thermal runaway process, and the resulting effects on the enclosure.

  11. Validity and Responsiveness of the Short Version of the Western Ontario Rotator Cuff Index (Short-WORC) in Patients With Rotator Cuff Repair.

    Science.gov (United States)

    Dewan, Neha; MacDermid, Joy C; MacIntyre, Norma

    2018-05-01

    Study Design Clinical measurement. Background Recently, the Western Ontario Rotator Cuff Index (WORC) was shortened, but few studies have reported its measurement properties. Objective To compare the validity and responsiveness of the short version of the Western Ontario Rotator Cuff Index (Short-WORC) and the WORC (disease-specific measures) with those of the Shoulder Pain and Disability Index (SPADI) and the simple shoulder test (SST) (joint-specific measures); the Disabilities of the Arm, Shoulder and Hand (DASH) (a region-specific measure); and the Medical Outcomes Study 12-Item Short-Form Health Survey version 2 (SF-12v2) (a general health status measure) in patients undergoing rotator cuff repair (RCR). Methods A cohort of patients (n = 223) completed the WORC, SPADI, SST, DASH, and SF-12v2 preoperatively and at 3 and 6 months after RCR. Short-WORC scores were extracted from the WORC questionnaire. The construct validity (Pearson correlations) and internal responsiveness (effect size [ES], standardized response mean [SRM], relative efficiency [RE]) of the Short-WORC were calculated. Results The Short-WORC was strongly correlated with the WORC (r = 0.89-0.96) and moderately to strongly correlated with non-disease-specific measures at preoperative and postoperative assessments (r = 0.51-0.92). The Short-WORC and WORC were equally responsive (RE Short-WORC/WORC = 1) at 0 to 6 months and highly responsive overall at 0 to 3 months (ES Short-WORC , 0.72; ES WORC , 0.92; SRM Short-WORC , 0.75; SRM WORC , 0.81) and 0 to 6 months (ES Short-WORC , 1.05; ES WORC , 1.12; SRM Short-WORC , 0.89; SRM WORC , 0.89). The responsiveness of the comparator measures (SPADI, SST, DASH, SF-12v2) was poor to moderate at 0 to 3 months (ES, 0.07-0.55; SRM, 0.09-0.49) and 0 to 6 months (ES, 0.05-0.78; SRM, 0.07-0.78). Conclusion The Short-WORC and WORC have similar responsiveness in patients undergoing RCR, and are more responsive than non-disease-specific measures. Future studies

  12. Standard review plan for the review and evaluation of emergency plans for research and test reactors. Technical report

    International Nuclear Information System (INIS)

    Bates, E.F.; Grimes, B.K.; Ramos, S.L.

    1982-05-01

    This document provides a Standard Review Plan for the guidance of the NRC staff to assure that complete and uniform reviews are made of research and test reactor emergency plans. The report is organized under ten planning standards which correspond to the guidance criteria in Draft II of ANSI/ANS 15.16 as endorsed by Revision 1 to Regulatory Guide 2.6. The applicability of the items under each planning standard is indicated by subdivisions of the steady state thermal power levels at which the reactors are licensed to operate. Standard emergency classes and example action levels for research and test reactors which should initiate these classes are given in an Appendix

  13. Standardization work by ASTM and DIN concerning test methods for metallic materials - comparative assessment with regard for practice

    International Nuclear Information System (INIS)

    Gerischer, K.

    1986-01-01

    The article explains the significant role of ASTM and marks out basic elements of the specification system of ASTM standards. Usefulness in practice is taken as the main criterion for the subsequent comparison of ASTM or DIN activities and procedures, and results, for standardization in the field of test methods for metallic materials. The main differences are shown to exist with regard to tropicality of test standards, presentation of useful information and background knowledge, and importance attached to formal questions. ASTM standardization work is shown to be more up-to-date, contain more information, and to be less concerned with formal matters. A closer cooperation between ASTM and DIN is strongly recommended. (orig.) [de

  14. Comparing the Effects of Elementary Music and Visual Arts Lessons on Standardized Mathematics Test Scores

    Science.gov (United States)

    King, Molly Elizabeth

    2016-01-01

    The purpose of this quantitative, causal-comparative study was to compare the effect elementary music and visual arts lessons had on third through sixth grade standardized mathematics test scores. Inferential statistics were used to compare the differences between test scores of students who took in-school, elementary, music instruction during the…

  15. Effects of acute caffeine withdrawal on Short Category Test performance in sleep-deprived individuals.

    Science.gov (United States)

    Killgore, William D S; Kahn-Greene, Ellen T; Killgore, Desiree B; Kamimori, Gary H; Balkin, Thomas J

    2007-12-01

    Caffeine is a popular stimulant often used to counter the effects of sleep loss and fatigue. Withdrawal from caffeine may produce mild declines in simple cognitive capacities such as attention and concentration, but it is unclear whether more complex cognitive functions, such as abstract reasoning or concept formation, may be similarly affected. To assess the effect of acute caffeine withdrawal on executive functioning during sleep deprivation, 26 healthy volunteers were administered in double-blind form either repeated doses of caffeine or placebo over two nights of continuous wakefulness. The 108-item Short Category Test was administered after 56 hr. of total sleep deprivation (9 hr. post-caffeine administration). The caffeine group scored significantly more poorly, making approximately 57% more errors on the test than the placebo group. These findings suggest that acute caffeine withdrawal during prolonged sleep deprivation has an adverse effect on abstract reasoning and concept formation.

  16. Report on the Test and Evaluation of the Kinemetrics/Quanterra Q730B Borehole Digitizers; TOPICAL

    International Nuclear Information System (INIS)

    KROMER, RICHARD P.; MCDONALD, TIMOTHY S.

    1999-01-01

    Sandia National Laboratories has tested and evaluated the Kinemetrics/Quanterra Q730B-bb (broadband) and Q730B-sp (short period) borehole installation remote digitizers. The test results included in this report were for response to static and dynamic input signals, seismic application performance, data time-tag accuracy, and reference signal generator (calibrator) performance. Most test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and P1241 (Preliminary Draft) for Analog to Digital Converters; others were designed by Sandia specifically for seismic application evaluation and for supplementary criteria not addressed in the IEEE standards. When appropriate, test instrumentation calibration is traceable to the National Institute for Standards Technology (NIST)

  17. Standard test methods for chemical and spectrochemical analysis of nuclear-Grade silver-indium-cadmium alloys

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1990-01-01

    1.1 These test methods cover procedures for the chemical and spectrochemical analysis of nuclear grade silver-indium-cadmium (Ag-In-Cd) alloys to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Sections Silver, Indium, and Cadmium by a Titration Method 7-15 Trace Impurities by Carrier-Distillation Spectro- chemical Method 16-22 1.3 The values stated in SI units are to be regarded as the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard and precautionary statements, see Section 5 and Practices E50. 7.1 This test method is applicable to the determination of silver, indium, and cadmium in alloys of approximately 80 % silver, 15 % indium, and 5 % cadmium used in nuclear reactor control r...

  18. Standard test method for determination of breaking strength of ceramic tiles by three-point loading

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2001-01-01

    1.1 This test method covers the determination of breaking strength of ceramic tiles by three-point loading. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. Development of a Standard Test to Assess the Resistance of Staphylococcus aureus Biofilm Cells to Disinfectants

    NARCIS (Netherlands)

    Luppens, S.B.I.; Reij, M.W.; Heijden, van der R.W.; Rombouts, F.M.; Abee, T.

    2002-01-01

    A standardized disinfectant test for Staphylococcus aureus cells in biofilms was developed. Two disinfectants, the membrane-active compound benzalkonium chloride (BAC) and the oxidizing agent sodium hypochlorite, were used to evaluate the biofilm test. S. aureus formed biofilms on glass, stainless

  20. Implementing a Standardized Social Networks Testing Strategy in a Low HIV Prevalence Jurisdiction.

    Science.gov (United States)

    Schumann, Casey; Kahn, Danielle; Broaddus, Michelle; Dougherty, Jacob; Elderbrook, Megan; Vergeront, James; Westergaard, Ryan

    2018-05-15

    Alternative HIV testing strategies are needed to engage individuals not reached by traditional clinical or non-clinical testing programs. A social networks recruitment strategy, in which people at risk for or living with HIV are enlisted and trained by community-based agencies to recruit individuals from their social, sexual, or drug-using networks for HIV testing, demonstrates higher positivity rates compared to other non-clinical recruitment strategies in some jurisdictions. During 2013-2015, a social networks testing protocol was implemented in Wisconsin to standardize an existing social networks testing program. Six community-based, non-clinical agencies with multiple sites throughout the state implemented the protocol over the 2-year period. Both quantitative and qualitative data were collected. The new positivity rate (0.49%) through social networks testing did not differ from that of traditional counseling, testing, and referral recruitment methods (0.48%). Although social networks testing did not yield a higher new positivity rate compared to other testing strategies, it proved to be successful at reaching high risk individuals who may not otherwise engage in HIV testing.

  1. Consensus-based reporting standards for diagnostic test accuracy studies for paratuberculosis in ruminants

    DEFF Research Database (Denmark)

    Gardner, Ian A.; Nielsen, Søren Saxmose; Whittington, Richard

    2011-01-01

    The Standards for Reporting of Diagnostic Accuracy (STARD) statement (www.stard-statement.org) was developed to encourage complete and transparent reporting of key elements of test accuracy studies in human medicine. The statement was motivated by widespread evidence of bias in test accuracy...... studies and the finding that incomplete or absent reporting of items in the STARD checklist was associated with overly optimistic estimates of test performance characteristics. Although STARD principles apply broadly, specific guidelines do not exist to account for unique considerations in livestock...... for Reporting of Animal Diagnostic Accuracy Studies for paratuberculosis), should facilitate improved quality of reporting of the design, conduct and results of paratuberculosis test accuracy studies which were identified as “poor” in a review published in 2008 in Veterinary Microbiology...

  2. Standard test method for quantitative determination of americium 241 in plutonium by Gamma-Ray spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1994-01-01

    1.1 This test method covers the quantitative determination of americium 241 by gamma-ray spectrometry in plutonium nitrate solution samples that do not contain significant amounts of radioactive fission products or other high specific activity gamma-ray emitters. 1.2 This test method can be used to determine the americium 241 in samples of plutonium metal, oxide and other solid forms, when the solid is appropriately sampled and dissolved. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. Final test report for traffic management data dictionary (TMDD) and related standards as deployed by the Utah department of transportation.

    Science.gov (United States)

    2008-05-23

    This report presents the results of the ITS Standards Testing Program for the field testing, assessment, and evaluation of the three volumes comprising the Standards for Traffic Management Center to Center Communications (TMDD) version 2.1 and the NT...

  4. Analysis of Power Transfer Efficiency of Standard Integrated Circuit Immunity Test Methods

    Directory of Open Access Journals (Sweden)

    Hai Au Huynh

    2015-01-01

    Full Text Available Direct power injection (DPI and bulk current injection (BCI methods are defined in IEC 62132-3 and IEC 62132-4 as the electromagnetic immunity test method of integrated circuits (IC. The forward power measured at the RF noise generator when the IC malfunctions is used as the measure of immunity level of the IC. However, the actual power that causes failure in ICs is different from forward power measured at the noise source. Power transfer efficiency is used as a measure of power loss of the noise injection path. In this paper, the power transfer efficiencies of DPI and BCI methods are derived and validated experimentally with immunity test setup of a clock divider IC. Power transfer efficiency varies significantly over the frequency range as a function of the test method used and the IC input impedance. For the frequency range of 15 kHz to 1 GHz, power transfer efficiency of the BCI test was constantly higher than that of the DPI test. In the DPI test, power transfer efficiency is particularly low in the lower test frequency range up to 10 MHz. When performing the IC immunity tests following the standards, these characteristics of the test methods need to be considered.

  5. FY 2000 Immediate-effect type project for research and development for international standards supporting information technology industries. Comprehensive study on promotion of international standardization; 2000 nendo joho sangyo shien sokkogata kokusai hyojun kaihatsu jigyo seika hokokusho. Kokusai hyojunka suishin ni kakawaru sogo chosa kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    The information technology and international standardization are studied for the elementary information technology, mechanical safety areas and electronic trading, aimed at achieving the international standards in a short time for the information industrial sector, which shows rapid technological development. The program for the elementary information technology includes development/standardization of the testing/evaluation methods for transparent electroconductive films for notebook computers, liquid crystal monitors or the like, specifically for the mechanical and physical properties. The program for mechanical safety areas includes definition of the closed space type mechanical safety monitoring techniques and use of safety-confirmation type sensors for the techniques, and standardization of the requirements of the protectors for use of the safety-confirmation type sensors, among others. The program for the electronic trading includes standardization of the electronic catalogues of the instrumentation devices, dictionaries of the instrumentation devices and device-screening processes. The other efforts include development of the applications and system infrastructure functions, construction of the demonstration test systems, and demonstration tests. (NEDO)

  6. The BACHD Rat Model of Huntington Disease Shows Signs of Fronto-Striatal Dysfunction in Two Operant Conditioning Tests of Short-Term Memory.

    Directory of Open Access Journals (Sweden)

    Erik Karl Håkan Clemensson

    Full Text Available The BACHD rat is a recently developed transgenic animal model of Huntington disease, a progressive neurodegenerative disorder characterized by extensive loss of striatal neurons. Cognitive impairments are common among patients, and characterization of similar deficits in animal models of the disease is therefore of interest. The present study assessed the BACHD rats' performance in the delayed alternation and the delayed non-matching to position test, two Skinner box-based tests of short-term memory function. The transgenic rats showed impaired performance in both tests, indicating general problems with handling basic aspects of the tests, while short-term memory appeared to be intact. Similar phenotypes have been found in rats with fronto-striatal lesions, suggesting that Huntington disease-related neuropathology might be present in the BACHD rats. Further analyses indicated that the performance deficit in the delayed alternation test might be due to impaired inhibitory control, which has also been implicated in Huntington disease patients. The study ultimately suggests that the BACHD rats might suffer from neuropathology and cognitive impairments reminiscent of those of Huntington disease patients.

  7. The BACHD Rat Model of Huntington Disease Shows Signs of Fronto-Striatal Dysfunction in Two Operant Conditioning Tests of Short-Term Memory.

    Science.gov (United States)

    Clemensson, Erik Karl Håkan; Clemensson, Laura Emily; Riess, Olaf; Nguyen, Huu Phuc

    2017-01-01

    The BACHD rat is a recently developed transgenic animal model of Huntington disease, a progressive neurodegenerative disorder characterized by extensive loss of striatal neurons. Cognitive impairments are common among patients, and characterization of similar deficits in animal models of the disease is therefore of interest. The present study assessed the BACHD rats' performance in the delayed alternation and the delayed non-matching to position test, two Skinner box-based tests of short-term memory function. The transgenic rats showed impaired performance in both tests, indicating general problems with handling basic aspects of the tests, while short-term memory appeared to be intact. Similar phenotypes have been found in rats with fronto-striatal lesions, suggesting that Huntington disease-related neuropathology might be present in the BACHD rats. Further analyses indicated that the performance deficit in the delayed alternation test might be due to impaired inhibitory control, which has also been implicated in Huntington disease patients. The study ultimately suggests that the BACHD rats might suffer from neuropathology and cognitive impairments reminiscent of those of Huntington disease patients.

  8. Testing for Unit Roots in Small Panels with Short-run and Long-run Cross-sectional Dependencies

    OpenAIRE

    Yoosoon Chang; Wonho Song

    2009-01-01

    An IV approach, using as instruments non-linear transformations of the lagged levels, is explored to test for unit roots in panels with general dependency and heterogeneity across cross-sectional units. We allow not only for the cross-sectional dependencies of innovations, but also for the presence of co-integration across cross-sectional levels. Unbalanced panels and panels with differing individual short-run dynamics and cross-sectionally related dynamics are also permitted. We also more ca...

  9. Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Nickel

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers procedures for measuring reaction rates by the activation reaction 58Ni(n,p)58Co. 1.2 This activation reaction is useful for measuring neutrons with energies above approximately 2.1 MeV and for irradiation times up to about 200 days in the absence of high thermal neutron fluence rates (for longer irradiations, see Practice E 261). 1.3 With suitable techniques fission-neutron fluence rates densities above 107 cm−2·s−1 can be determined. 1.4 Detailed procedures for other fast-neutron detectors are referenced in Practice E 261. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Note—The burnup corrections were com...

  10. On-Demand Cell Internal Short Circuit Device

    Science.gov (United States)

    Darcy, Eric; Keyser, Matthew

    2014-01-01

    A device implantable in Li-ion cells that can generate a hard internal short circuit on-demand by exposing the cell to 60?C has been demonstrated to be valuable for expanding our understanding of cell responses. The device provides a negligible impact to cell performance and enables the instigation of the 4 general categories of cell internal shorts to determine relative severity and cell design susceptibility. Tests with a 18650 cell design indicates that the anode active material short to the aluminum cathode current collector tends to be more catastrophic than the 3 other types of internal shorts. Advanced safety features (such as shutdown separators) to prevent or mitigate the severity of cell internal shorts can be verified with this device. The hard short success rate achieved to date in 18650 cells is about 80%, which is sufficient for using these cells in battery assemblies for field-failure-relevant, cell-cell thermal runaway propagation verification tests

  11. Assessing Resilience in Students Who Are Deaf or Blind: Supplementing Standardized Achievement Testing

    Science.gov (United States)

    Butler, Michelle A.; Katayama, Andrew D.; Schindling, Casey; Dials, Katherine

    2018-01-01

    Although testing accommodations for standardized assessments are available for students with disabilities, interpretation remains challenging. The authors explored resilience to see if it could contribute to the interpretation of academic success for students who are deaf or hard of hearing or blind or have low vision. High school students (30…

  12. Comprehensive School Reform and Standardized Test Scores in Illinois Elementary and Middle Schools

    Science.gov (United States)

    McEnroe, James D.

    2010-01-01

    The study examined the effects of the federally funded Comprehensive School Reform (CSR) program on student performance on mandated standardized tests. The study focused on the mathematics and reading scores of Illinois public elementary and middle and junior high school students. The federal CSR program provided Illinois schools with an annual…

  13. Chaos and Complexities Theories. Superposition and Standardized Testing: Are We Coming or Going?

    Science.gov (United States)

    Erwin, Susan

    2005-01-01

    The purpose of this paper is to explore the possibility of using the principle of "superposition of states" (commonly illustrated by Schrodinger's Cat experiment) to understand the process of using standardized testing to measure a student's learning. Comparisons from literature, neuroscience, and Schema Theory will be used to expound upon the…

  14. Development of an ASTM standard glass durability test, the Product Consistency Test (PCT), for high level radioactive waste glass

    International Nuclear Information System (INIS)

    Jantzen, C.M.; Bibler, N.E.; Beam, D.C.; Ramsey, W.G.

    1994-01-01

    The nation's first, and the world's largest, facility to immobilize high-level nuclear waste in durable borosilicate glass has started operation at the Savannah River Site (SRS) in Aiken, South Carolina. The product specifications on the glass wasteform produced in the Defense Waste Processing Facility (DWPF) required extensive characterization of the glass product before actual production began and for continued characterization during production. To aid in this characterization, a glass durability (leach) test was needed that was easily reproducible, could be performed remotely on highly radioactive samples, and could yield results rapidly. Several standard leach tests were examined with a variety of test configurations. Using existing tests as a starting point, the DWPF Product Consistency Test (PCT was developed in which crushed glass samples are exposed to 90 ± 2 degree C deionized water for seven days. Based on extensive testing, including a seven-laboratory round robin and confirmatory testing with radioactive samples, the PCT is very reproducible, yields reliable results rapidly, and can be performed in shielded cell facilities with radioactive samples

  15. The University of Minnesota aquifer thermal energy storage (ATES) field test facility -- system description, aquifer characterization, and results of short-term test cycles

    Energy Technology Data Exchange (ETDEWEB)

    Walton, M.; Hoyer, M.C.; Eisenreich, S.J.; Holm, N.L.; Holm, T.R.; Kanivetsky, R.; Jirsa, M.A.; Lee, H.C.; Lauer, J.L.; Miller, R.T.; Norton, J.L.; Runke, H. (Minnesota Geological Survey, St. Paul, MN (United States))

    1991-06-01

    Phase 1 of the Aquifer Thermal Energy Storage (ATES) Project at the University of Minnesota was to test the feasibility, and model, the ATES concept at temperatures above 100{degrees}C using a confined aquifer for the storage and recovery of hot water. Phase 1 included design, construction, and operation of a 5-MW thermal input/output field test facility (FTF) for four short-term ATES cycles (8 days each of heat injection, storage, and heat recover). Phase 1 was conducted from May 1980 to December 1983. This report describes the FTF, the Franconia-Ironton-Galesville (FIG) aquifer used for the test, and the four short-term ATES cycles. Heat recovery; operational experience; and thermal, chemical, hydrologic, and geologic effects are all included. The FTF consists of monitoring wells and the source and storage well doublet completed in the FIG aquifer with heat exchangers and a fixed-bed precipitator between the wells of the doublet. The FIG aquifer is highly layered and a really anisotropic. The upper Franconia and Ironton-Galesville parts of the aquifer, those parts screened, have hydraulic conductivities of {approximately}0.6 and {approximately}1.0 m/d, respectively. Primary ions in the ambient ground water are calcium and magnesium bicarbonate. Ambient temperature FIG ground water is saturated with respect to calcium/magnesium bicarbonate. Heating the ground water caused most of the dissolved calcium to precipitate out as calcium carbonate in the heat exchanger and precipitator. Silica, calcium, and magnesium were significantly higher in recovered water than in injected water, suggesting dissolution of some constituents of the aquifer during the cycles. Further work on the ground water chemistry is required to understand water-rock interactions.

  16. Achievement Gap Projection for Standardized Testing through Logistic Regression within a Large Arizona School District

    Science.gov (United States)

    Kellermeyer, Steven Bruce

    2011-01-01

    In the last few decades high-stakes testing has become more political than educational. The Districts within Arizona are bound by the mandates of both AZ LEARNS and the No Child Left Behind Act of 2001. At the time of this writing, both legislative mandates relied on the Arizona Instrument for Measuring Standards (AIMS) as State Tests for gauging…

  17. Dynamic visual noise reduces confidence in short-term memory for visual information.

    Science.gov (United States)

    Kemps, Eva; Andrade, Jackie

    2012-05-01

    Previous research has shown effects of the visual interference technique, dynamic visual noise (DVN), on visual imagery, but not on visual short-term memory, unless retention of precise visual detail is required. This study tested the prediction that DVN does also affect retention of gross visual information, specifically by reducing confidence. Participants performed a matrix pattern memory task with three retention interval interference conditions (DVN, static visual noise and no interference control) that varied from trial to trial. At recall, participants indicated whether or not they were sure of their responses. As in previous research, DVN did not impair recall accuracy or latency on the task, but it did reduce recall confidence relative to static visual noise and no interference. We conclude that DVN does distort visual representations in short-term memory, but standard coarse-grained recall measures are insensitive to these distortions.

  18. Working on a Standard Joint Unit: A pilot test.

    Science.gov (United States)

    Casajuana, Cristina; López-Pelayo, Hugo; Mercedes Balcells, María; Miquel, Laia; Teixidó, Lídia; Colom, Joan; Gual, Antoni

    2017-09-29

    Assessing cannabis consumption remains complex due to no reliable registration systems. We tested the likelihood of establishing a Standard Joint Unit (SJU) which considers the main cannabinoids with implication on health through a naturalistic approach.  Methodology. Pilot study with current cannabis users of four areas of Barcelona: universities, nightclubs, out-patient mental health service, and cannabis associations. We designed and administered a questionnaire on cannabis use-patterns and determined the willingness to donate a joint for analysis. Descriptive statistics were used to analyze the data. Forty volunteers answered the questionnaire (response rate 95%); most of them were men (72.5%) and young adults (median age 24.5 years; IQR 8.75 years) who consume daily or nearly daily (70%). Most participants consume marihuana (85%) and roll their joints with a median of 0.25 gr of marihuana. Two out of three (67.5%) stated they were willing to donate a joint. Obtaining an SJU with the planned methodology has proved to be feasible. Pre-testing resulted in an improvement of the questionnaire and retribution to incentivize donations. Establishing an SJU is essential to improve our knowledge on cannabis-related outcomes.

  19. The Inter Facility Testing of a Standard Oscillating Water Column (OWC) Type Wave Energy Converter (WEC)

    DEFF Research Database (Denmark)

    Andersen, Morten Thøtt; Thomsen, Jonas Bjerg

    This report describes the behavior and preliminary performance of a simplified standard oscillating water column (OWC) wave energy converter (WEC). The same tests will be conducted at different scales at 6 different test facilities and the results obtained will be used for comparison. This project...

  20. Utilization of ISO 6892:2009 testing standard for determining tensile properties of TM380 mild steel

    CSIR Research Space (South Africa)

    Shoke, L

    2013-04-01

    Full Text Available mild steel. To achieve this objective, we reviewed the ISO 6892:2009 tensile testing standard along with reported good practice guidelines. Tensile tests were conducted on a dog-bone shaped TM380 mild steel specimen with strain gauges attached on either...