WorldWideScience

Sample records for short test correlation

  1. Short-range correlations with pseudopotentials

    International Nuclear Information System (INIS)

    Osman, A.

    1976-01-01

    Short-range correlations in nuclei are considered on an unitary-model operator approach. Short-range pseudopotentials have been added to achieve healing in the correlated wave functions. With the introduction of the pseudopotentials, correlated basis wave functions are constructed. The matrix element for effective interaction in nuclei is developed. The required pseudopotentials have been calculated for the Hamda-Johnston, Yale and Reid potentials and for the nuclear nucleon-nucleon potential A calculated by us according to meson exchange between nucleons. (Osman, A.)

  2. Short-term test-retest-reliability of conditioned pain modulation using the cold-heat-pain method in healthy subjects and its correlation to parameters of standardized quantitative sensory testing.

    Science.gov (United States)

    Gehling, Julia; Mainka, Tina; Vollert, Jan; Pogatzki-Zahn, Esther M; Maier, Christoph; Enax-Krumova, Elena K

    2016-08-05

    Conditioned Pain Modulation (CPM) is often used to assess human descending pain inhibition. Nine different studies on the test-retest-reliability of different CPM paradigms have been published, but none of them has investigated the commonly used heat-cold-pain method. The results vary widely and therefore, reliability measures cannot be extrapolated from one CPM paradigm to another. Aim of the present study was to analyse the test-retest-reliability of the common heat-cold-pain method and its correlation to pain thresholds. We tested the short-term test-retest-reliability within 40 ± 19.9 h using a cold-water immersion (10 °C, left hand) as conditioning stimulus (CS) and heat pain (43-49 °C, pain intensity 60 ± 5 on the 101-point numeric rating scale, right forearm) as test stimulus (TS) in 25 healthy right-handed subjects (12females, 31.6 ± 14.1 years). The TS was applied 30s before (TSbefore), during (TSduring) and after (TSafter) the 60s CS. The difference between the pain ratings for TSbefore and TSduring represents the early CPM-effect, between TSbefore and TSafter the late CPM-effect. Quantitative sensory testing (QST, DFNS protocol) was performed on both sessions before the CPM assessment. paired t-tests, Intraclass correlation coefficient (ICC), standard error of measurement (SEM), smallest real difference (SRD), Pearson's correlation, Bland-Altman analysis, significance level p Pain ratings during CPM correlated significantly (ICC: 0.411…0.962) between both days, though ratings for TSafter were lower on day 2 (p pain thresholds. The short-term test-retest-reliability of the early CPM-effect using the heat-cold-pain method in healthy subjects achieved satisfying results in terms of the ICC. The SRD of the early CPM effect showed that an individual change of > 20 NRS can be attributed to a real change rather than chance. The late CPM-effect was weaker and not reliable.

  3. Short- circuit tests of circuit breakers

    OpenAIRE

    Chorovský, P.

    2015-01-01

    This paper deals with short-circuit tests of low voltage electrical devices. In the first part of this paper, there are described basic types of short- circuit tests and their principles. Direct and indirect (synthetic) tests with more details are described in the second part. Each test and principles are explained separately. Oscilogram is obtained from short-circuit tests of circuit breakers at laboratory. The aim of this research work is to propose a test circuit for performing indirect test.

  4. SHORT COMMUNICATION: Reduction of Spirometric Lung Function Tests in Habitually Smoking Healthy Young Adults: It’s Correlation with Pack Years

    Directory of Open Access Journals (Sweden)

    Sumangala M Patil

    2012-01-01

    Full Text Available Background: Adolescent smoking and the subsequent health problems are a major concern today. However there are very few studies done on spirometric lung functions and its relation with pack years in young adult habitual smokers who are apparently healthy. Aims and Objectives: The present study is undertaken to assess the change in lung functions in apparently healthy young adult habitual smokers compared to their age matched controls. Materials and Methods: A random sample of apparently healthy young adult habitual smokers (n=40 and nonsmokers (n=40 between age group17-35 years with history suggesting of pack years of 2-10 years were selected from students & employee’s of B.L.D.E.U’s Sri B.M. Patil Medical College,Hospital & Research Centre Bijapur (Karnataka, India. Spirometric lung functions recorded were forced expiratory volume in one second (FEV1, FEV1%, Peak expiratory flow rate (PEFR and Maximal expiratory pressure (MEP. Results: The results suggested that inapparently healthy habitual smokers there was significant decrease in FEV1 (L (-13.34%, p<0.001, FEV1 % (-10.76%, p<0.001, PEFR (-45.26%, p<0.0001 and MEP (-35.51%, p<0.0001 compared to nonsmokers and decrease in FEV1 was negatively correlated withpack years in smokers (r2=0.063, p=0.001. Reduced lung functions and negative correlation to pack years may be attributed todecreased airway diameter & reflex broncho- constriction in response to inhaled smoke particles. Conclusions: In conclusion young adulthabitual smokers who were apparently healthy are more prone for respiratory dysfunction than their nonsmoker counterparts. FEV1 reduction in relation to pack years acts as an important determinant for detecting lung dysfunction in the early stage of the disease. As the risk of having smoking related diseases depends mainly on number of pack years, it is suggested that quitting smoking earliest helps to get greatest health benefits in apparently healthy young adult habitual smokers.

  5. Isobar configurations in nuclei and short range correlations

    CERN Document Server

    Weber, H J

    1979-01-01

    Recent results on short range correlations and isobar configurations are reviewed, and in particular a unitary version of the isobar model, coupling constants and rho -meson transition potentials, a comparison with experiments, the CERN N*-knockout from /sup 4/He, QCD and the NN interaction of short range. (42 refs).

  6. Uncovering the mutation-fixation correlation in short lineages

    Directory of Open Access Journals (Sweden)

    Vallender Eric J

    2007-09-01

    Full Text Available Abstract Background We recently reported a highly unexpected positive correlation between the fixation probability of nonsynonymous mutations (estimated by ω and neutral mutation rate (estimated by Ks in mammalian lineages. However, this positive correlation was observed for lineages with relatively long divergence time such as the human-mouse lineage, and was not found for very short lineages such as the human-chimpanzee lineage. It was previously unclear how to interpret this discrepancy. It may indicate that the positive correlation between ω and Ks in long lineages is a false finding. Alternatively, it may reflect a biologically meaningful difference between various lineages. Finally, the lack of positive correlation in short lineages may be the result of methodological artifacts. Results Here we show that a strong positive correlation can indeed be seen in short lineages when a method was introduced to correct for the inherently high levels of stochastic noise in the use of Ks as an estimator of neutral mutation rate. Thus, the previously noted lack of positive correlation between ω and Ks in short lineages is due to stochastic noise in Ks that makes it a far less reliable estimator of neutral mutation rate in short lineages as compared to long lineages. Conclusion A positive correlation between ω and Ks can be observed in all mammalian lineages for which large amounts of sequence data are available, including very short lineages. It confirms the authenticity of this highly unexpected correlation, and argues that the correction likely applies broadly across all mammals and perhaps even non-mammalian species.

  7. Hard probes of short-range nucleon-nucleon correlations

    Energy Technology Data Exchange (ETDEWEB)

    J. Arrington, D. W. Higinbotham, G. Rosner, M. Sargsian

    2012-10-01

    The strong interaction of nucleons at short distances leads to a high-momentum component to the nuclear wave function, associated with short-range correlations between nucleons. These short-range, high-momentum structures in nuclei are one of the least well understood aspects of nuclear matter, relating to strength outside of the typical mean-field approaches to calculating the structure of nuclei. While it is difficult to study these short-range components, significant progress has been made over the last decade in determining how to cleanly isolate short-range correlations in nuclei. We have moved from asking if such structures exist, to mapping out their strength in nuclei and studying their microscopic structure. A combination of several different measurements, made possible by high-luminosity and high-energy accelerators, coupled with an improved understanding of the reaction mechanism issues involved in studying these structures, has led to significant progress, and provided significant new information on the nature of these small, highly-excited structures in nuclei. We review the general issues related to short-range correlations, survey recent experiments aimed at probing these short-range structures, and lay out future possibilities to further these studies.

  8. A default Bayesian hypothesis test for correlations and partial correlations

    NARCIS (Netherlands)

    Wetzels, R.; Wagenmakers, E.J.

    2012-01-01

    We propose a default Bayesian hypothesis test for the presence of a correlation or a partial correlation. The test is a direct application of Bayesian techniques for variable selection in regression models. The test is easy to apply and yields practical advantages that the standard frequentist tests

  9. Short-range correlations in quark and nuclear matter

    Energy Technology Data Exchange (ETDEWEB)

    Froemel, Frank

    2007-06-15

    In the first part of this thesis, the role of short-range correlations in quark matter is explored within the framework of the Nambu-Jona-Lasinio model. Starting from a next-to-leading order expansion in the inverse number of the quark colors, a fully self-consistent model constructed that employs the close relations between spectral functions and self-energies. In contrast to the usual quasiparticle approximations, this approach allows the investigation of the collisional broadening of the quark spectral function. Numerical calculations at various chemical potentials and zero temperature show that the short-range correlations do not only induce a finite width of the spectral function but also have some influence on the structure of the chiral phase transition. In the second part of this thesis, the temperature and density dependence of the nucleon spectral function in symmetric nuclear matter is investigated. The short-range correlations can be well described by a simple, self-consistent model on the one-particle-two-hole and two-particle-one-hole level (1p2h, 2p1h). The thermodynamically consistent description of the mean-field properties of the nucleons is ensured by incorporating a Skyrme-type potential. Calculations at temperatures and densities that can also be found in heavy-ion collisions or supernova explosions and the formation of neutron stars show that the correlations saturate at high temperatures and densities. (orig.)

  10. LS1 Report: short-circuit tests

    CERN Multimedia

    Katarina Anthony

    2014-01-01

    As the LS1 draws to an end, teams move from installation projects to a phase of intense testing. Among these are the so-called 'short-circuit tests'. Currently under way at Point 7, these tests verify the cables, the interlocks, the energy extraction systems, the power converters that provide current to the superconducting magnets and the cooling system.   Thermal camera images taken during tests at point 4 (IP4). Before putting beam into the LHC, all of the machine's hardware components need to be put to the test. Out of these, the most complicated are the superconducting circuits, which have a myriad of different failure modes with interlock and control systems. While these will be tested at cold - during powering tests to be done in August - work can still be done beforehand. "While the circuits in the magnets themselves cannot be tested at warm, what we can do is verify the power converter and the circuits right up to the place the cables go into the magn...

  11. Rapidity correlations test stochastic hydrodynamics

    International Nuclear Information System (INIS)

    Zin, C; Gavin, S; Moschelli, G

    2017-01-01

    We show that measurements of the rapidity dependence of transverse momentum correlations can be used to determine the characteristic time τ π that dictates the rate of isotropization of the stress energy tensor, as well as the shear viscosity ν = η/sT . We formulate methods for computing these correlations using second order dissipative hydrodynamics with noise. Current data are consistent with τ π /ν ∼ 10 but targeted measurements can improve this precision. (paper)

  12. Nonequilibrium Physics at Short Time Scales: Formation of Correlations

    International Nuclear Information System (INIS)

    Peliti, L

    2005-01-01

    It is a happy situation when similar concepts and theoretical techniques can be applied to widely different physical systems because of a deep similarity in the situations being studied. The book illustrates this well; it focuses on the description of correlations in quantum systems out of equilibrium at very short time scales, prompted by experiments with short laser pulses in semiconductors, and in complex reactions in heavy nuclei. In both cases the experiments are characterized by nonlinear dynamics and by strong correlations out of equilibrium. In some systems there are also important finite-size effects. The book comprises several independent contributions of moderate length, and I sometimes felt that a more intensive effort in cross-coordination of the different contributions could have been of help. It is divided almost equally between theory and experiment. In the theoretical part, there is a thorough discussion both of the kinematic aspects (description of correlations) and the dynamical ones (evaluation of correlations). The experimental part is naturally divided according to the nature of the system: the interaction of pulsed lasers with matter on the one hand, and the correlations in finite-size systems (nanoparticles and nuclei) on the other. There is also a discussion on the dynamics of superconductors, a subject currently of great interest. Although an effort has been made to keep each contribution self-contained, I must admit that reading level is uneven. However, there are a number of thorough and stimulating contributions that make this book a useful introduction to the topic at the level of graduate students or researchers acquainted with quantum statistical mechanics. (book review)

  13. The nuclear contacts and short range correlations in nuclei

    Science.gov (United States)

    Weiss, R.; Cruz-Torres, R.; Barnea, N.; Piasetzky, E.; Hen, O.

    2018-05-01

    Atomic nuclei are complex strongly interacting systems and their exact theoretical description is a long-standing challenge. An approximate description of nuclei can be achieved by separating its short and long range structure. This separation of scales stands at the heart of the nuclear shell model and effective field theories that describe the long-range structure of the nucleus using a mean-field approximation. We present here an effective description of the complementary short-range structure using contact terms and stylized two-body asymptotic wave functions. The possibility to extract the nuclear contacts from experimental data is presented. Regions in the two-body momentum distribution dominated by high-momentum, close-proximity, nucleon pairs are identified and compared to experimental data. The amount of short-range correlated (SRC) nucleon pairs is determined and compared to measurements. Non-combinatorial isospin symmetry for SRC pairs is identified. The obtained one-body momentum distributions indicate dominance of SRC pairs above the nuclear Fermi-momentum.

  14. Hypothesis testing for differentially correlated features.

    Science.gov (United States)

    Sheng, Elisa; Witten, Daniela; Zhou, Xiao-Hua

    2016-10-01

    In a multivariate setting, we consider the task of identifying features whose correlations with the other features differ across conditions. Such correlation shifts may occur independently of mean shifts, or differences in the means of the individual features across conditions. Previous approaches for detecting correlation shifts consider features simultaneously, by computing a correlation-based test statistic for each feature. However, since correlations involve two features, such approaches do not lend themselves to identifying which feature is the culprit. In this article, we instead consider a serial testing approach, by comparing columns of the sample correlation matrix across two conditions, and removing one feature at a time. Our method provides a novel perspective and favorable empirical results compared with competing approaches. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. Testing power-law cross-correlations: Rescaled covariance test

    Czech Academy of Sciences Publication Activity Database

    Krištoufek, Ladislav

    2013-01-01

    Roč. 86, č. 10 (2013), 418-1-418-15 ISSN 1434-6028 R&D Projects: GA ČR GA402/09/0965 Institutional support: RVO:67985556 Keywords : power-law cross-correlations * testing * long-term memory Subject RIV: AH - Economics Impact factor: 1.463, year: 2013 http://library.utia.cas.cz/separaty/2013/E/kristoufek-testing power-law cross-correlations rescaled covariance test.pdf

  16. A novel nuclear dependence of nucleon–nucleon short-range correlations

    Energy Technology Data Exchange (ETDEWEB)

    Dai, Hongkai [College of Physics and Electronic Engineering, Northwest Normal University, Lanzhou 730070 (China); Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Wang, Rong, E-mail: rwang@impcas.ac.cn [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Lanzhou University, Lanzhou 730000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Huang, Yin [Lanzhou University, Lanzhou 730000 (China); Chen, Xurong [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China)

    2017-06-10

    A linear correlation is found between the magnitude of nucleon–nucleon short-range correlations and the nuclear binding energy per nucleon with pairing energy removed. By using this relation, the strengths of nucleon–nucleon short-range correlations of some unmeasured nuclei are predicted. Discussions on nucleon–nucleon pairing energy and nucleon–nucleon short-range correlations are made. The found nuclear dependence of nucleon–nucleon short-range correlations may shed some lights on the short-range structure of nucleus.

  17. Charge correlations as definitive tests of QCD

    International Nuclear Information System (INIS)

    Maxwell, C.J.

    1981-07-01

    Certain weighted charge correlations are defined and it is shown how they can be used to measure properties of the gluon jet in the e + e - 3-jet final state. Properties are suggested which are indicative of the form of the QCD matrix element, the running coupling constant and value of Λ, and hence constitute definitive tests of QCD. The recent near tenfold increase in luminosity at PETRA should make such experimental tests possible in the near future. (author)

  18. Short range correlations in high energy heavy ion collisions

    International Nuclear Information System (INIS)

    Franco, V.; Nutt, W.T.

    1978-01-01

    We present a technique for including the effects of nucleon-nucleon correlations in the optical phase shift (chi) expansion of the nucleus-nucleus scattering amplitude and present the results for chi to second order. The total and inelastic cross sections are consistently higher than those obtained ignoring correlations, and are in better agreement with the data. Furthermore, the inclusion of correlations leads to second order phase shift functions which do not violate unitarity, in constrast to the case when correlations are ignored in very heavy nuclei (A 1 , A 2 > or approx. = 200). In elastic scattering differential cross sections, the effects of correlations can be quite large

  19. Testing for Short Memory in a VARMA Process

    OpenAIRE

    Oke, Timothy; Öller, Lars-Erik

    1997-01-01

    We generalize the short term memory test of an ARMA model, presented in Öller (1985), to the multivariate VARMA cases. In a study on Swedish exports and OECD demand we demonstrate how the multivariate setting extends the short memory.

  20. Visuospatial and Verbal Short-Term Memory Correlates of Vocabulary Ability in Preschool Children.

    Science.gov (United States)

    Stokes, Stephanie F; Klee, Thomas; Kornisch, Myriam; Furlong, Lisa

    2017-08-16

    Recent studies indicate that school-age children's patterns of performance on measures of verbal and visuospatial short-term memory (STM) and working memory (WM) differ across types of neurodevelopmental disorders. Because these disorders are often characterized by early language delay, administering STM and WM tests to toddlers could improve prediction of neurodevelopmental outcomes. Toddler-appropriate verbal, but not visuospatial, STM and WM tasks are available. A toddler-appropriate visuospatial STM test is introduced. Tests of verbal STM, visuospatial STM, expressive vocabulary, and receptive vocabulary were administered to 92 English-speaking children aged 2-5 years. Mean test scores did not differ for boys and girls. Visuospatial and verbal STM scores were not significantly correlated when age was partialed out. Age, visuospatial STM scores, and verbal STM scores accounted for unique variance in expressive (51%, 3%, and 4%, respectively) and receptive vocabulary scores (53%, 5%, and 2%, respectively) in multiple regression analyses. Replication studies, a fuller test battery comprising visuospatial and verbal STM and WM tests, and a general intelligence test are required before exploring the usefulness of these STM tests for predicting longitudinal outcomes. The lack of an association between the STM tests suggests that the instruments have face validity and test independent STM skills.

  1. Electrical short circuit and current overload tests on aircraft wiring

    Science.gov (United States)

    Cahill, Patricia

    1995-01-01

    The findings of electrical short circuit and current overload tests performed on commercial aircraft wiring are presented. A series of bench-scale tests were conducted to evaluate circuit breaker response to overcurrent and to determine if the wire showed any visible signs of thermal degradation due to overcurrent. Three types of wire used in commercial aircraft were evaluated: MIL-W-22759/34 (150 C rated), MIL-W-81381/12 (200 C rated), and BMS 1360 (260 C rated). A second series of tests evaluated circuit breaker response to short circuits and ticking faults. These tests were also meant to determine if the three test wires behaved differently under these conditions and if a short circuit or ticking fault could start a fire. It is concluded that circuit breakers provided reliable overcurrent protection. Circuit breakers may not protect wire from ticking faults but can protect wire from direct shorts. These tests indicated that the appearance of a wire subjected to a current that totally degrades the insulation looks identical to a wire subjected to a fire; however the 'fire exposed' conductor was more brittle than the conductor degraded by overcurrent. Preliminary testing indicates that direct short circuits are not likely to start a fire. Preliminary testing indicated that direct short circuits do not erode insulation and conductor to the extent that ticking faults did. Circuit breakers may not safeguard against the ignition of flammable materials by ticking faults. The flammability of materials near ticking faults is far more important than the rating of the wire insulation material.

  2. A short note on jackknifing the concordance correlation coefficient.

    Science.gov (United States)

    Feng, Dai; Baumgartner, Richard; Svetnik, Vladimir

    2014-02-10

    Lin's concordance correlation coefficient (CCC) is a very popular scaled index of agreement used in applied statistics. To obtain a confidence interval (CI) for the estimate of CCC, jackknifing was proposed and shown to perform well in simulation as well as in applications. However, a theoretical proof of the validity of the jackknife CI for the CCC has not been presented yet. In this note, we establish a sufficient condition for using the jackknife method to construct the CI for the CCC. Copyright © 2013 John Wiley & Sons, Ltd.

  3. Gas temperature measurements in short duration turbomachinery test facilities

    Science.gov (United States)

    Cattafesta, L. N.; Epstein, A. H.

    1988-07-01

    Thermocouple rakes for use in short-duration turbomachinery test facilities have been developed using very fine thermocouples. Geometry variations were parametrically tested and showed that bare quartz junction supports (76 microns in diameter) yielded superior performance, and were rugged enough to survive considerable impact damage. Using very low cost signal conditioning electronics, temperature accuracies of 0.3 percent were realized yielding turbine efficiency measurements at the 1-percent level. Ongoing work to improve this accuracy is described.

  4. The pricing of long and short run variance and correlation risk in stock returns

    NARCIS (Netherlands)

    Cosemans, M.

    2011-01-01

    This paper studies the pricing of long and short run variance and correlation risk. The predictive power of the market variance risk premium for returns is driven by the correlation risk premium and the systematic part of individual variance premia. Furthermore, I find that aggregate volatility risk

  5. The multidimensional correlates associated with short nocturnal sleep duration and subjective insomnia among Taiwanese adolescents.

    Science.gov (United States)

    Yen, Cheng-Fang; Ko, Chih-Hung; Yen, Ju-Yu; Cheng, Chung-Ping

    2008-11-01

    The aim of this study was to examine the correlates associated with short nocturnal sleep duration and subjective insomnia, including individual factors, family factors, peer factors, school factors, and the problematic use of high-tech devices among a large-scale representative population of Taiwanese adolescents. Cross-sectional study. A total of 23 junior high and 29 senior high/vocational schools were randomly selected across southern Taiwan. Eight thousand four adolescent students. N/A. The multidimensional correlates associated with short nocturnal sleep duration and subjective insomnia were examined using chi2 automatic interaction detection analysis and logistic regression analysis models. The results indicated that an older age, self-reported depression, being in the third year of school, drinking coffee at night, and problematic Internet use were significantly associated with short nocturnal sleep duration in adolescents. Furthermore, self-reported depression, low school affinity, high family conflict, low connectedness to their peer group, and problematic Internet use were associated with subjective insomnia in adolescents. The results of this study indicate that a variety of individual, family, peer, and school factors were associated with short nocturnal sleep duration and subjective insomnia in adolescents. Furthermore, the correlates of short sleep duration were not identical to those of subjective insomnia. Parents and health professionals should be wary of sleep patterns among adolescents who have the identified correlates of short nocturnal sleep duration and subjective insomnia.

  6. X-ray testing for short-time dynamic applications

    International Nuclear Information System (INIS)

    Kurfiss, Malte; Moser, Stefan; Popko, Gregor; Nau, Siegfried

    2017-01-01

    For nondestructive testing purposes new challenges are short-time dynamic processes. The application of x-ray flash tubes and modern high-speed cameras allows the observation of the opening of air-bags or the energy absorption of compressed tubes as occurring during a vehicle crash. Special algorithms designed for computerized tomography analyses allow the 3D reconstruction at individual time points of the dynamic process. Possibilities and limitations of the actual techniques are discussed.

  7. Vietnamese validation of the short version of Internet Addiction Test

    OpenAIRE

    Tran, Bach Xuan; Mai, Hue Thi; Nguyen, Long Hoang; Nguyen, Cuong Tat; Latkin, Carl A.; Zhang, Melvyn W.B.; Ho, Roger C.M.

    2017-01-01

    Background and aims: The main goal of the present study was to examine the psychometric properties of a Vietnamese version of the short-version of Internet Addiction Test (s-IAT) and to assess the relationship between s-IAT scores and demographics, health related qualify of life and perceived stress scores in young Vietnamese. Methods: The Vietnamese version of s-IAT was administered to a sample of 589 participants. Exploratory factor and reliability analyses were performed. Regression analys...

  8. Correlation between Very Short and Short-Term Blood Pressure Variability in Diabetic-Hypertensive and Healthy Subjects.

    Science.gov (United States)

    Casali, Karina R; Schaan, Beatriz D; Montano, Nicola; Massierer, Daniela; M F Neto, Flávio; Teló, Gabriela H; Ledur, Priscila S; Reinheimer, Marilia; Sbruzzi, Graciele; Gus, Miguel

    2018-02-01

    Blood pressure (BP) variability can be evaluated by 24-hour ambulatory BP monitoring (24h-ABPM), but its concordance with results from finger BP measurement (FBPM) has not been established yet. The aim of this study was to compare parameters of short-term (24h-ABPM) with very short-term BP variability (FBPM) in healthy (C) and diabetic-hypertensive (DH) subjects. Cross-sectional study with 51 DH subjects and 12 C subjects who underwent 24h-ABPM [extracting time-rate, standard deviation (SD), coefficient of variation (CV)] and short-term beat-to-beat recording at rest and after standing-up maneuvers [FBPM, extracting BP and heart rate (HR) variability parameters in the frequency domain, autoregressive spectral analysis]. Spearman correlation coefficient was used to correlate BP and HR variability parameters obtained from both FBPM and 24h-ABPM (divided into daytime, nighttime, and total). Statistical significance was set at p ABPM) and LF component of short-term variability (FBPM, total, R = 0.591, p = 0.043); standard deviation (24h-ABPM) with LF component BPV (FBPM, total, R = 0.608, p = 0.036), coefficient of variation (24h-ABPM) with total BPV (FBPM, daytime, -0.585, p = 0.046) and alpha index (FBPM, daytime, -0.592, p = 0.043), time rate (24h-ABPM) and delta LF/HF (FBPM, total, R = 0.636, p = 0.026; daytime R = 0,857, p ABPM (total, daytime) reflect BP and HR variability evaluated by FBPM in healthy individuals. This does not apply for DH subjects.

  9. Probing short-range correlations in asymmetric nuclei with quasi-free pair knockout reactions

    Science.gov (United States)

    Stevens, Sam; Ryckebusch, Jan; Cosyn, Wim; Waets, Andreas

    2018-02-01

    Short-range correlations (SRC) in asymmetric nuclei with an unusual neutron-to-proton ratio can be studied with quasi-free two-nucleon knockout processes following the collision between accelerated ions and a proton target. We derive an approximate factorized cross section for those SRC-driven p (A ,p‧N1N2) reactions. Our reaction model hinges on the factorization properties of SRC-driven A (e ,e‧N1N2) reactions for which strong indications are found in theory-experiment comparisons. In order to put our model to the test we compare its predictions with results of 12C (p ,p‧ pn) measurements conducted at Brookhaven National Laboratory (BNL) and find a fair agreement. The model can also reproduce characteristic features of SRC-driven two-nucleon knockout reactions, like back-to-back emission of the correlated nucleons. We study the asymmetry dependence of nuclear SRC by providing predictions for the ratio of proton-proton to proton-neutron knockout cross sections for the carbon isotopes 9-15C thereby covering neutron excess values (N - Z) / Z between -0.5 and +0.5.

  10. Effects of correlation in transition radiation of super-short electron bunches

    Science.gov (United States)

    Danilova, D. K.; Tishchenko, A. A.; Strikhanov, M. N.

    2017-07-01

    The effect of correlations between electrons in transition radiation is investigated. The correlation function is obtained with help of the approach similar to the Debye-Hückel theory. The corrections due to correlations are estimated to be near 2-3% for the parameters of future projects SINBAD and FLUTE for bunches with extremely small lengths (∼1-10 fs). For the bunches with number of electrons about ∼ 2.5 ∗1010 and more, and short enough that the radiation would be coherent, the corrections due to correlations are predicted to reach 20%.

  11. The sensitivity testing of Wilms' tumors to cytostatic agents with an autoradiographic in vitro short-term test

    International Nuclear Information System (INIS)

    Willnow, U.

    1984-01-01

    Sensitivity of 15 Wilms' tumors in children was tested towards cytostatic agents in vitro by means of an autoradiographic short-term test. Sensitivity was measured as the magnitude of the inhibition of 3 H-thymidine or 3 H-uridine incorporation. The test was performed with Adriamycin, Actinomycin D, Daunomycin, Bleomycin, Cyclophosphamide, Ifosfamide, Trenimon, and Arabinosylcytosine. None of the tumors is resistant to all substances, they are responsive against 2 or more drugs. The most effective drugs tested are Adriamycin, Actinomycin D and Cyclophosphamide. The tumors show a marked individual sensitivity pattern. This behavior is explained mainly by the usually high proliferative activity of Wilms' tumors. The possibilities and limits of long-term and short-term methods for sensitivity testing are discussed critically. For the evaluation of the results of in vitro testing and in vivo effectiveness the close correlation should be considered between the type of cytostatic agent and proliferation kinetics of the tumor, cytostatic agent and effect on tumor metabolism as well as the effect of the cytostatics and the nucleic acid precursors used for the short-term test. Despite the methodological limitations preclinical testing should be preferred to unselected chemotherapy. (author)

  12. Prospective testing of Coulomb short-term earthquake forecasts

    Science.gov (United States)

    Jackson, D. D.; Kagan, Y. Y.; Schorlemmer, D.; Zechar, J. D.; Wang, Q.; Wong, K.

    2009-12-01

    Earthquake induced Coulomb stresses, whether static or dynamic, suddenly change the probability of future earthquakes. Models to estimate stress and the resulting seismicity changes could help to illuminate earthquake physics and guide appropriate precautionary response. But do these models have improved forecasting power compared to empirical statistical models? The best answer lies in prospective testing in which a fully specified model, with no subsequent parameter adjustments, is evaluated against future earthquakes. The Center of Study of Earthquake Predictability (CSEP) facilitates such prospective testing of earthquake forecasts, including several short term forecasts. Formulating Coulomb stress models for formal testing involves several practical problems, mostly shared with other short-term models. First, earthquake probabilities must be calculated after each “perpetrator” earthquake but before the triggered earthquakes, or “victims”. The time interval between a perpetrator and its victims may be very short, as characterized by the Omori law for aftershocks. CSEP evaluates short term models daily, and allows daily updates of the models. However, lots can happen in a day. An alternative is to test and update models on the occurrence of each earthquake over a certain magnitude. To make such updates rapidly enough and to qualify as prospective, earthquake focal mechanisms, slip distributions, stress patterns, and earthquake probabilities would have to be made by computer without human intervention. This scheme would be more appropriate for evaluating scientific ideas, but it may be less useful for practical applications than daily updates. Second, triggered earthquakes are imperfectly recorded following larger events because their seismic waves are buried in the coda of the earlier event. To solve this problem, testing methods need to allow for “censoring” of early aftershock data, and a quantitative model for detection threshold as a function of

  13. Radon risk perception and testing: Sociodemographic correlates

    International Nuclear Information System (INIS)

    Halpern, M.T.; Warner, K.E.

    1994-01-01

    While numerous health education campaigns have been carried out to alert the public to radon's potential dangers and to encourage testing and mitigation, there has been little follow-up to determine which segments of the public are now most aware of the possible hazards of radon. Using information from the 1990 National Health Interview Survey (NHIS), the authors have examined beliefs regarding radon and radon-testing activities among different sociodemographic groups. They used logistic regression to determine the relationship between these beliefs and actions and age, gender, education, income, minority status, and smoking status. The results suggest relatively superficial knowledge regarding radon, and very little testing, within the survey population. In particular, significantly less knowledge was observed among female and minority respondents, while less testing behavior was seen among older respondents. Lower educational levels and lower family income were associated with both decreased knowledge and testing. Recommendations for future education campaigns are discussed

  14. Effects of Repeated Testing on Short- and Long-Term Memory Performance across Different Test Formats

    Science.gov (United States)

    Stenlund, Tova; Sundström, Anna; Jonsson, Bert

    2016-01-01

    This study examined whether practice testing with short-answer (SA) items benefits learning over time compared to practice testing with multiple-choice (MC) items, and rereading the material. More specifically, the aim was to test the hypotheses of "retrieval effort" and "transfer appropriate processing" by comparing retention…

  15. Short-term memory deficits correlate with hippocampal-thalamic functional connectivity alterations following acute sleep restriction.

    Science.gov (United States)

    Chengyang, Li; Daqing, Huang; Jianlin, Qi; Haisheng, Chang; Qingqing, Meng; Jin, Wang; Jiajia, Liu; Enmao, Ye; Yongcong, Shao; Xi, Zhang

    2017-08-01

    Acute sleep restriction heavily influences cognitive function, affecting executive processes such as attention, response inhibition, and memory. Previous neuroimaging studies have suggested a link between hippocampal activity and short-term memory function. However, the specific contribution of the hippocampus to the decline of short-term memory following sleep restriction has yet to be established. In the current study, we utilized resting-state functional magnetic resonance imaging (fMRI) to examine the association between hippocampal functional connectivity (FC) and the decline of short-term memory following total sleep deprivation (TSD). Twenty healthy adult males aged 20.9 ± 2.3 years (age range, 18-24 years) were enrolled in a within-subject crossover study. Short-term memory and FC were assessed using a Delay-matching short-term memory test and a resting-state fMRI scan before and after TSD. Seed-based correlation analysis was performed using fMRI data for the left and right hippocampus to identify differences in hippocampal FC following TSD. Subjects demonstrated reduced alertness and a decline in short-term memory performance following TSD. Moreover, fMRI analysis identified reduced hippocampal FC with the superior frontal gyrus (SFG), temporal regions, and supplementary motor area. In addition, an increase in FC between the hippocampus and bilateral thalamus was observed, the extent of which correlated with short-term memory performance following TSD. Our findings indicate that the disruption of hippocampal-cortical connectivity is linked to the decline in short-term memory observed after acute sleep restriction. Such results provide further evidence that support the cognitive impairment model of sleep deprivation.

  16. Testing Cross-Sectional Correlation in Large Panel Data Models with Serial Correlation

    Directory of Open Access Journals (Sweden)

    Badi H. Baltagi

    2016-11-01

    Full Text Available This paper considers the problem of testing cross-sectional correlation in large panel data models with serially-correlated errors. It finds that existing tests for cross-sectional correlation encounter size distortions with serial correlation in the errors. To control the size, this paper proposes a modification of Pesaran’s Cross-sectional Dependence (CD test to account for serial correlation of an unknown form in the error term. We derive the limiting distribution of this test as N , T → ∞ . The test is distribution free and allows for unknown forms of serial correlation in the errors. Monte Carlo simulations show that the test has good size and power for large panels when serial correlation in the errors is present.

  17. Short Circuit Tests First Step of LHC Hardware Commissioning Completion

    CERN Document Server

    Barbero-Soto, E; Bordry, Frederick; Casas Lino, M P; Coelingh, G J; Cumer, G; Dahlerup-Petersen, K; Guillaume, J C; Inigo-Golfin, J; Montabonnet, V; Nisbet, D; Pojer, M; Principe, R; Rodríguez-Mateos, F; Saban, R; Schmidt, R; Thiesen, H; Vergara-Fernández, A; Zerlauth, M; Castaneda Serra, A; Romera Ramirez, I

    2008-01-01

    For the two counter rotating beams in the Large Hadron Collider (LHC) about 8000 magnets (main dipole and quadrupole magnets, corrector magnets, separation dipoles, matching section quadrupoles etc.) are powered in about 1500 superconducting electrical circuits. The magnets are powered by power converters that have been designed for the LHC with a current between 60 and 13000A. Between October 2005 and September 2007 the so-called Short Circuit Tests were carried-out in 15 underground zones where the power converters of the superconducting circuits are placed. The tests aimed to qualify the normal conducting equipments of the circuits such as power converters and normal conducting high current cables. The correct operation of interlock and energy extraction systems was validated. The infrastructure systems including AC distribution, water and air cooling and the control systems was also commissioned. In this paper the results of the two year test campaign are summarized with particular attention to problems e...

  18. Short term mutagenicity tests and their application to irradiated foods

    International Nuclear Information System (INIS)

    Phillips, B.J.; Elias, P.S.

    1980-01-01

    Although traditional long-term animal tests are likely to continue to be required, these are not only extremely costly but are coming more and more to be recognised as an imprecise and unsatisfactory method of testing the safety of irradiated foods for human consumption. It is therefore clearly advisable to include a selection of quicker and more direct testing methods in any toxicological assessment procedures. The International Project has therefore undertaken a study of the feasibility of using the newer systems for investigation of irradiated foodstuffs. Although some work in this field has already been carried out, some shortcomings in the published work can be identified which justify a more detailed and intensive research programme. As expected, little difficulty has been encountered in testing food by methods involving mammals, but considerable effort has been required to adapt in vitro systems. The use of enzymatic digestion in vitro to provide food samples for testing in mammalian cell cultures has never been attempted before and the procedures developed by the Project represent a positive contribution to methodology in this field. A series of foodstuffs is being tested by a wide spectrum of short-term tests and the first results are now being obtained. (orig./MG) [de

  19. Experimental tests of induced spatial incoherence using short laser wavelength

    International Nuclear Information System (INIS)

    Obenschain, S.P.; Grun, J.; Herbst, M.J.

    1986-01-01

    The authors have developed a laser beam smoothing technique called induced spatial incoherence (ISI), which can produce the highly uniform focal profiles required for direct-drive laser fusion. Uniform well-controlled focal profiles are required to obtain the highly symmetric pellet implosions needed for high-energy gain. In recent experiments, the authors' tested the effects of ISI on high-power laser-target interaction. With short laser wavelength, the coupling physics dramatically improved over that obtained with an ordinary laser beam

  20. Observation of short range three-particle correlations in e+e- annihilations at LEP energies

    CERN Document Server

    Abreu, P; Adye, T; Agasi, E; Ajinenko, I; Aleksan, Roy; Alekseev, G D; Allport, P P; Almehed, S; Alvsvaag, S J; Amaldi, Ugo; Amato, S; Andreazza, A; Andrieux, M L; Antilogus, P; Apel, W D; Arnoud, Y; Augustin, J E; Augustinus, A; Baillon, Paul; Bambade, P; Barate, R; Barbiellini, Guido; Bardin, Dimitri Yuri; Barker, G J; Baroncelli, A; Barrio, J A; Bartl, Walter; Barão, F; Bates, M J; Battaglia, Marco; Baubillier, M; Baudot, J; Becks, K H; Begalli, M; Beillière, P; Belokopytov, Yu A; Belous, K S; Benvenuti, Alberto C; Berggren, M; Bertrand, D; Bianchi, F; Bigi, M; Bilenky, S M; Billoir, P; Bloch, D; Blume, M; Blyth, S; Bocci, V; Bolognese, T; Bonesini, M; Bonivento, W; Booth, P S L; Borisov, G; Bosio, C; Bosworth, S; Botner, O; Bouquet, B; Bourdarios, C; Bowcock, T J V; Bozzo, M; Branchini, P; Brand, K D; Brenner, R A; Bricman, C; Brillault, L; Brown, R C A; Brunet, J M; Brückman, P; Bugge, L; Buran, T; Buys, A; Bärring, O; Caccia, M; Calvi, M; Camacho-Rozas, A J; Camporesi, T; Canale, V; Canepa, M; Cankocak, K; Cao, F; Carena, F; Carrilho, P; Carroll, L; Caso, Carlo; Castillo-Gimenez, M V; Cattai, A; Cavallo, F R; Cerrito, L; Chabaud, V; Charpentier, P; Chaussard, L; Chauveau, J; Checchia, P; Chelkov, G A; Chierici, R; Chochula, P; Chorowicz, V; Cindro, V; Collins, P; Contreras, J L; Contri, R; Cortina, E; Cosme, G; Cossutti, F; Crawley, H B; Crennell, D J; Crosetti, G; Cuevas-Maestro, J; Czellar, S; D'Almagne, B; Da Silva, W; Dahl-Jensen, Erik; Dahm, J; Dam, M; Damgaard, G; Daum, A; Dauncey, P D; Davenport, Martyn; De Angelis, A; De Boeck, H; De Brabandere, S; De Clercq, C; De Lotto, B; De Min, A; De Paula, L S; De Saint-Jean, C; Defoix, C; Della Ricca, G; Delpierre, P A; Demaria, N; Di Ciaccio, Lucia; Dijkstra, H; Djama, F; Dolbeau, J; Doroba, K; Dracos, M; Drees, J; Drees, K A; Dris, M; Dufour, Y; Dupont, F; Dönszelmann, M; Edsall, D M; Ehret, R; Eigen, G; Ekelöf, T J C; Ekspong, Gösta; Elsing, M; Engel, J P; Ershaidat, N; Erzen, B; Espirito-Santo, M C; Falk, E; Fassouliotis, D; Feindt, Michael; Fenyuk, A; Ferrer, A; Filippas-Tassos, A; Firestone, A; Fischer, P A; Fokitis, E; Fontanelli, F; Formenti, F; Franek, B J; Frenkiel, P; Fries, D E C; Frodesen, A G; Frühwirth, R; Fulda-Quenzer, F; Fuster, J A; Föth, H; Fürstenau, H; Galloni, A; Gamba, D; Gandelman, M; García, C; García, J; Gaspar, C; Gasparini, U; Gavillet, P; Gazis, E N; Gelé, D; Gerber, J P; Gibbs, M; Gillespie, D; Gokieli, R; Golob, B; Gopal, Gian P; Gorn, L; Gracco, Valerio; Graziani, E; Grosdidier, G; Gunnarsson, P; Guy, J; Guz, Yu; Górski, M; Günther, M; Haedinger, U; Hahn, F; Hahn, M; Hahn, S; Hajduk, Z; Hallgren, A; Hamacher, K; Hao, W; Harris, F J; Hedberg, V; Henriques, R P; Hernández, J J; Herquet, P; Herr, H; Hessing, T L; Higón, E; Hilke, Hans Jürgen; Hill, T S; Holmgren, S O; Holt, P J; Holthuizen, D J; Houlden, M A; Huet, K; Hultqvist, K; Ioannou, P; Jackson, J N; Jacobsson, R; Jalocha, P; Janik, R; Jarlskog, G; Jarry, P; Jean-Marie, B; Johansson, E K; Joram, Christian; Juillot, P; Jönsson, L B; Jönsson, P E; Kaiser, M; Kalmus, George Ernest; Kapusta, F; Karlsson, M; Karvelas, E; Katargin, A; Katsanevas, S; Katsoufis, E C; Keränen, R; Khomenko, B A; Khovanskii, N N; King, B J; Kjaer, N J; Klein, H; Klovning, A; Kluit, P M; Kokkinias, P; Koratzinos, M; Kostyukhin, V; Kourkoumelis, C; Kramer, P H; Krammer, Manfred; Kreuter, C; Kronkvist, I J; Krumshtein, Z; Krupinski, W; Królikowski, J; Kubinec, P; Kucewicz, W; Kurvinen, K L; Kuznetsov, O; Köhne, J H; Köne, B; La Vaissière, C de; Lacasta, C; Laktineh, I; Lamblot, S; Lamsa, J; Lanceri, L; Lane, D W; Langefeld, P; Lapin, V; Last, I; Laugier, J P; Lauhakangas, R; Leder, Gerhard; Ledroit, F; Lefébure, V; Legan, C K; Leitner, R; Lemoigne, Y; Lemonne, J; Lenzen, Georg; Lepeltier, V; Lesiak, T; Liko, D; Lindner, R; Lipniacka, A; Lippi, I; Lokajícek, M; Loken, J G; Loukas, D; Lutz, P; Lyons, L; López, J M; López-Aguera, M A; López-Fernandez, A; Lörstad, B; MacNaughton, J N; Maehlum, G; Maio, A; Malychev, V; Mandl, F; Marco, J; Margoni, M; Marin, J C; Mariotti, C; Markou, A; Maron, T; Martí i García, S; Martínez-Rivero, C; Martínez-Vidal, F; Maréchal, B; Matorras, F; Matteuzzi, C; Matthiae, Giorgio; Mazzucato, M; McCubbin, M L; McKay, R; McNulty, R; Medbo, J; Meroni, C; Meyer, W T; Michelotto, M; Migliore, E; Mirabito, L; Mitaroff, Winfried A; Mjörnmark, U; Moa, T; Monge, M R; Morettini, P; Mundim, L M; Murray, W J; Muryn, B; Myagkov, A; Myatt, Gerald; Mönig, K; Møller, R; Müller, H; Naraghi, F; Navarria, Francesco Luigi; Navas, S; Negri, P; Neumann, W; Neumeister, N; Nicolaidou, R; Nielsen, B S; Nieuwenhuizen, M; Nikolaenko, V; Niss, P; Nomerotski, A; Normand, Ainsley; Némécek, S; Oberschulte-Beckmann, W; Obraztsov, V F; Olshevskii, A G; Onofre, A; Orava, Risto; Ouraou, A; Paganini, P; Paganoni, M; Pagès, P; Palka, H; Papadopoulou, T D; Pape, L; Parkes, C; Parodi, F; Passeri, A; Pegoraro, M; Peralta, L; Pernegger, H; Pernicka, Manfred; Perrotta, A; Petridou, C; Petrolini, A; Phillips, H T; Piana, G; Pierre, F; Pimenta, M; Plaszczynski, S; Podobrin, O; Pol, M E; Polok, G; Poropat, P; Pozdnyakov, V; Prest, M; Privitera, P; Pukhaeva, N; Pullia, Antonio; Radojicic, D; Ragazzi, S; Rahmani, H; Rames, J; Ratoff, P N; Read, A L; Reale, M; Rebecchi, P; Redaelli, N G; Regler, Meinhard; Reid, D; Renton, P B; Resvanis, L K; Richard, F; Richardson, J; Rinaudo, G; Ripp, I; Romero, A; Roncagliolo, I; Ronchese, P; Roos, L; Rosenberg, E I; Rosso, E; Roudeau, Patrick; Rovelli, T; Ruhlmann-Kleider, V; Ruiz, A; Rídky, J; Rückstuhl, W; Saarikko, H; Sacquin, Yu; Sadovskii, A; Sajot, G; Salt, J; Sannino, M; Schneider, H; Schyns, M A E; Sciolla, G; Scuri, F; Sedykh, Yu; Segar, A M; Seitz, A; Sekulin, R L; Shellard, R C; Siccama, I; Siegrist, P; Simonetti, S; Simonetto, F; Sissakian, A N; Sitár, B; Skaali, T B; Smadja, G; Smirnov, N; Smirnova, O G; Smith, G R; Sokolov, A; Sosnowski, R; Souza-Santos, D; Spassoff, Tz; Spiriti, E; Squarcia, S; Stanescu, C; Stapnes, Steinar; Stavitski, I; Stepaniak, K; Stichelbaut, F; Stocchi, A; Strauss, J; Strub, R; Stugu, B; Stäck, H; Szczekowski, M; Szeptycka, M; Sánchez, J; Tabarelli de Fatis, T; Tavernet, J P; Tilquin, A; Timmermans, J; Tkatchev, L G; Todorov, T; Toet, D Z; Tomaradze, A G; Tomé, B; Tortora, L; Tranströmer, G; Treille, D; Trischuk, W; Tristram, G; Trombini, A; Troncon, C; Tsirou, A L; Turluer, M L; Tyapkin, I A; Tyndel, M; Tzamarias, S; Ullaland, O; Valenti, G; Vallazza, E; Van Eldik, J; Van der Velde, C; Vassilopoulos, N; Vegni, G; Ventura, L; Venus, W A; Verbeure, F; Verlato, M; Vertogradov, L S; Vilanova, D; Vincent, P; Vitale, L; Vlasov, E; Vodopyanov, A S; Vrba, V; Wahlen, H; Walck, C; Wehr, A; Weierstall, M; Weilhammer, Peter; Wetherell, Alan M; Wicke, D; Wickens, J H; Wielers, M; Wilkinson, G R; Williams, W S C; Winter, M; Witek, M; Woschnagg, K; Yip, K; Yushchenko, O P; Zach, F; Zacharatou-Jarlskog, C; Zaitsev, A; Zalewska-Bak, A; Zalewski, Piotr; Zavrtanik, D; Zevgolatakos, E; Zimin, N I; Zito, M; Zontar, D; Zuberi, R; Zucchelli, G C; Zumerle, G; de Boer, Wim; van Apeldoorn, G W; van Dam, P; Åsman, B; Österberg, K; Überschär, B; Überschär, S

    1995-01-01

    \\def\\tpc{three-particle correlation} \\def\\twopc{two-particle correlation} Measurements are presented of short range three-particle correlations in e^+ e^- annihilations at LEP using data collected by the DELPHI detector. %The jet structure is studied using three-particle correlation functions. At small values of the four-momentum difference, strong three-particle correlations are observed for like-sign (+++ and ---) and for unlike-sign (++- and +--) pion combinations which are not a consequence of two-particle correlations. A possible explanation of the observed effects in like-sign combinations is the existence of higher order Bose-Einstein interference, which significantly changes the particle distributions in jets.

  1. Short-range and long-range correlations in DIS at HERA

    International Nuclear Information System (INIS)

    Chekanov, S. V.; Zawiejski, L.

    1999-01-01

    Correlations in deep-inelastic scattering (DIS) at HERA are investigated in order to test perturbative QCD and quark fragmentation universality. Two-particle correlations at small angular separations are measured in the Breit frame and compared to e + e - collisions. Also presented are the correlations between the current and target regions of the Breit frame

  2. Vietnamese validation of the short version of Internet Addiction Test

    Directory of Open Access Journals (Sweden)

    Bach Xuan Tran

    2017-12-01

    Full Text Available Background and aims: The main goal of the present study was to examine the psychometric properties of a Vietnamese version of the short-version of Internet Addiction Test (s-IAT and to assess the relationship between s-IAT scores and demographics, health related qualify of life and perceived stress scores in young Vietnamese. Methods: The Vietnamese version of s-IAT was administered to a sample of 589 participants. Exploratory factor and reliability analyses were performed. Regression analysis was used to identify the associated factors. Results: The two-factor model of Vietnamese version of s-IAT demonstrated good psychometric properties. The internal consistency of Factor 1 (loss of control/time management was high (Cronbach's alpha=0.82 and Factor 2 (craving/social problems was satisfactory (Cronbach's alpha=0.75. Findings indicated that 20.9% youths were addicted to the Internet. Regression analysis revealed significant associations between Internet addiction and having problems in self-care, lower quality of life and high perceived stress scores. Discussion and conclusions: The Vietnamese version of s-IAT is a valid and reliable instrument to assess IA in Vietnamese population. Due to the high prevalence of IA among Vietnamese youths, IA should be paid attention in future intervention programs. s-IAT can be a useful screening tool for IA to promptly inform and treat the IA among Vietnamese youths. Keywords: Factor analysis, Short-version, Internet Addiction Test, Psychometric properties, Vietnamese

  3. Diabetic Erythrocytes Test by Correlation Coefficient

    Science.gov (United States)

    Korol, A.M; Foresto, P; Darrigo, M; Rosso, O.A

    2008-01-01

    Even when a healthy individual is studied, his/her erythrocytes in capillaries continually change their shape in a synchronized erratic fashion. In this work, the problem of characterizing the cell behavior is studied from the perspective of bounded correlated random walk, based on the assumption that diffractometric data involves both deterministic and stochastic components. The photometric readings are obtained by ektacytometry over several millions of shear elongated cells, using a home-made device called Erythrodeformeter. We have only a scalar signal and no governing equations; therefore the complete behavior has to be reconstructed in an artificial phase space. To analyze dynamics we used the technique of time delay coordinates suggested by Takens, May algorithm, and Fourier transform. The results suggest that on random-walk approach the samples from healthy controls exhibit significant differences from those from diabetic patients and these could allow us to claim that we have linked mathematical nonlinear tools with clinical aspects of diabetic erythrocytes’ rheological properties. PMID:19415139

  4. Non-Normality and Testing that a Correlation Equals Zero

    Science.gov (United States)

    Levy, Kenneth J.

    1977-01-01

    The importance of the assumption of normality for testing that a bivariate normal correlation equals zero is examined. Both empirical and theoretical evidence suggest that such tests are robust with respect to violation of the normality assumption. (Author/JKS)

  5. Unitarity corrections to short-range order long-range rapidity correlations

    CERN Document Server

    Capella, A

    1978-01-01

    Although the effective hadronic forces have short range in rapidity space, one nevertheless expects long-range dynamical correlations induced by unitarity constraints. This paper contains a thorough discussion of long-range rapidity correlations in high-multiplicity events. In particular, the authors analyze in detail the forward- backward multiplicity correlations, measured recently in the whole CERN ISR energy range. They find from these data that the normalized variance of the number n of exchanged cut Pomerons, ((n/(n)-1)/sup 2/) , is most probably in the range 0.32 to 0.36. They show that such a number is obtained from Reggeon theory in the eikonal approximation. The authors also predict a very specific violation of local compensation of charge in multiparticle events: The violation should appear in the fourth-order zone correlation function and is absent in the second-order correlation function, the only one measured until now. (48 refs).

  6. Short-range correlations in an extended time-dependent mean-field theory

    International Nuclear Information System (INIS)

    Madler, P.

    1982-01-01

    A generalization is performed of the time-dependent mean-field theory by an explicit inclusion of strong short-range correlations on a level of microscopic reversibility relating them to realistic nucleon-nucleon forces. Invoking a least action principle for correlated trial wave functions, equations of motion for the correlation functions and the single-particle model wave function are derived in lowest order of the FAHT cluster expansion. Higher order effects as well as long-range correlations are consider only to the extent to which they contribute to the mean field via a readjusted phenomenological effective two-body interaction. The corresponding correlated stationary problem is investigated and appropriate initial conditions to describe a heavy ion reaction are proposed. The singleparticle density matrix is evaluated

  7. Testing the Difference of Correlated Agreement Coefficients for Statistical Significance

    Science.gov (United States)

    Gwet, Kilem L.

    2016-01-01

    This article addresses the problem of testing the difference between two correlated agreement coefficients for statistical significance. A number of authors have proposed methods for testing the difference between two correlated kappa coefficients, which require either the use of resampling methods or the use of advanced statistical modeling…

  8. Spectrum-energy Correlations in GRBs: Update, Reliability, and the Long/Short Dichotomy

    Science.gov (United States)

    Zhang, Z. B.; Zhang, C. T.; Zhao, Y. X.; Luo, J. J.; Jiang, L. Y.; Wang, X. L.; Han, X. L.; Terheide, R. K.

    2018-05-01

    Spectrum-energy correlations of peak energy with total prompt γ-ray emission energies, namely {E}p,i-{E}{iso}, {E}p,i-{E}γ , and {E}p,i-{L}p, had been studied for long gamma-ray bursts (GRBs) previously by many authors. These energy correlations were proposed to measure the universe and classify GRBs as useful probes. However, most of these relations were built by non-Swift bursts. The spectrum-energy correlations of short bursts have not been systematically established yet; in particular, how the newly found GRB170817A matches these energy relations is unknown to date. We will first refresh the three spectrum-energy relations of Swift/BAT and Fermi/GBM long bursts and build the corresponding relations of short bursts. Then, we confirm whether they are commonly available as a discriminator of short and long GRBs. Some potential violators to these relations will be investigated. Combining with the plane of peak energy versus fluence, we select 31 short and 252 long GRBs with well-measured peak energy and redshift to study the issue of GRB classifications connected with the above energy relations statistically. We find that the three energy relations do exist in our new GRB samples and they are marginally consistent with some previous results. We report for the first time that short GRBs hold the three corresponding energy relations having the consistent power-law indices with long GRBs. It is found that these energy relations can be adopted to discriminate GRBs successfully if they are put in the peak energy versus fluence plane. Excitingly, we point out that GRB090510 matches the energy relations of {E}p,i-{E}{iso} and {E}p,i-{L}p, but violates the {E}p,i-{E}γ relation. More excitingly, we find that GRB170817A is an outlier to all the three energy correlations.

  9. Quantifying and Reducing Uncertainty in Correlated Multi-Area Short-Term Load Forecasting

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Yannan; Hou, Zhangshuan; Meng, Da; Samaan, Nader A.; Makarov, Yuri V.; Huang, Zhenyu

    2016-07-17

    In this study, we represent and reduce the uncertainties in short-term electric load forecasting by integrating time series analysis tools including ARIMA modeling, sequential Gaussian simulation, and principal component analysis. The approaches are mainly focusing on maintaining the inter-dependency between multiple geographically related areas. These approaches are applied onto cross-correlated load time series as well as their forecast errors. Multiple short-term prediction realizations are then generated from the reduced uncertainty ranges, which are useful for power system risk analyses.

  10. Short-term static corrosion tests in lead-bismuth

    Science.gov (United States)

    Soler Crespo, L.; Martín Muñoz, F. J.; Gómez Briceño, D.

    2001-07-01

    Martensitic steels have been proposed to be used as structural materials and as spallation target window in hybrid systems devoted to the transmutation of radioactive waste of long life and high activity. However, their compatibility with lead-bismuth in the operating conditions of these systems depends on the existence of a protective layer such as an oxide film. The feasibility of forming and maintaining an oxide layer or maintaining a pre-oxidised one has been studied. Martensitic steel F82Hmod. (8% Cr) has been tested in lead-bismuth under static and isothermal conditions at 400°C and 600°C. In order to study the first stages of the interaction between the steel and the eutectic, short-term tests (100 and 665 h) have been carried out. Pre-oxidised and as-received samples have been tested in atmospheres with different oxidant potential. For low oxygen concentration in lead-bismuth due to unexpected oxygen consumption in the experimental device, dissolution of as-received F82Hmod. occurs and pre-oxidation does not prevent the material dissolution. For high oxygen concentration, the pre-oxidation layer seems to improve the feasibility of protecting stainless steels controlling the oxygen potential of lead-bismuth with a gas phase.

  11. Short-term static corrosion tests in lead-bismuth

    International Nuclear Information System (INIS)

    Soler Crespo, L.; Martin Munoz, F.J.; Gomez Briceno, D.

    2001-01-01

    Martensitic steels have been proposed to be used as structural materials and as spallation target window in hybrid systems devoted to the transmutation of radioactive waste of long life and high activity. However, their compatibility with lead-bismuth in the operating conditions of these systems depends on the existence of a protective layer such as an oxide film. The feasibility of forming and maintaining an oxide layer or maintaining a pre-oxidised one has been studied. Martensitic steel F82Hmod. (8% Cr) has been tested in lead-bismuth under static and isothermal conditions at 400 o C and 600 o C. In order to study the first stages of the interaction between the steel and the eutectic, short-term tests (100 and 665 h) have been carried out. Pre-oxidised and as-received samples have been tested in atmospheres with different oxidant potential. For low oxygen concentration in lead-bismuth due to unexpected oxygen consumption in the experimental device, dissolution of as-received F82Hmod. occurs and pre-oxidation does not prevent the material dissolution. For high oxygen concentration, the pre-oxidation layer seems to improve the feasibility of protecting stainless steels controlling the oxygen potential of lead-bismuth with a gas phase

  12. Mass dependence of short-range correlations in nuclei and the EMC effect

    Directory of Open Access Journals (Sweden)

    Cosyn Wim

    2014-03-01

    Full Text Available We sketch an approximate method to quantify the number of correlated pairs in any nucleus A. It is based on counting independent-particle model (IPM nucleon-nucleon pairs in a relative S-state with no radial excitation. We show that IPM pairs with those quantum numbers are most prone to short-range correlations and are at the origin of the high-momentum tail of the nuclear momentum distributions. Our method allows to compute the a2 ratios extracted from inclusive electron scattering. Furthermore, our results reproduce the observed linear correlation between the number of correlated pairs and the magnitude of the EMC effect. We show that the width of the pair center-ofmass distribution in exclusive two-nucleon knockout yields information on the quantum numbers of the pairs.

  13. n-p Short-Range Correlations from (p,2p+n) Measurements

    Science.gov (United States)

    Tang, A.; Watson, J. W.; Aclander, J.; Alster, J.; Asryan, G.; Averichev, Y.; Barton, D.; Baturin, V.; Bukhtoyarova, N.; Carroll, A.; Gushue, S.; Heppelmann, S.; Leksanov, A.; Makdisi, Y.; Malki, A.; Minina, E.; Navon, I.; Nicholson, H.; Ogawa, A.; Panebratsev, Yu.; Piasetzky, E.; Schetkovsky, A.; Shimanskiy, S.; Zhalov, D.

    2003-01-01

    We studied the 12C(p,2p+n) reaction at beam momenta of 5.9, 8.0, and 9.0 GeV/c. For quasielastic (p,2p) events pf, the momentum of the knocked-out proton before the reaction, was compared (event by event) with pn, the coincident neutron momentum. For |pn|>kF=0.220 GeV/c (the Fermi momentum) a strong back-to-back directional correlation between pf and pn was observed, indicative of short-range n-p correlations. From pn and pf we constructed the distributions of c.m. and relative motion in the longitudinal direction for correlated pairs. We also determined that 49±13% of events with |pf|>kF had directionally correlated neutrons with |pn|>kF.

  14. Quality Testing of Short Rotation Coppice Willow Cuttings

    Directory of Open Access Journals (Sweden)

    Katrin Heinsoo

    2018-06-01

    Full Text Available The production and feasibility of Short Rotation Coppice depend on cutting early performance. The shoot and root biomass production of Salix cuttings in hydroponic conditions was studied. The amount of sprouted biomass after four weeks of growth depended on cutting the diameter, but the original position of the cutting along the rod or number of visible buds was not in correlation with biomass produced. Application of mineral fertilizer or soil originating from the willow plantation did not increase the total production. On the contrary, the addition of soil tended to decrease biomass production and we assumed this was a result of a shortage of light. Under the influence of fertilization, plants allocated greater biomass to roots. Comparison of different clones revealed that those with S. dasyclados genes tended to allocate less biomass to roots and the poorest-performing clone in our experiment, also had the lowest wood production in the plantation. The number of visible buds on the cutting was also clone-specific.

  15. Characterizing short-range vs. long-range spatial correlations in dislocation distributions

    Energy Technology Data Exchange (ETDEWEB)

    Chevy, Juliette, E-mail: juliette.chevy@gmail.com [Laboratoire de Glaciologie et Geophysique de l' Environnement-CNRS, 54 rue Moliere, 38402 St. Martin d' Heres (France)] [Laboratoire Science et Ingenierie des Materiaux et Procedes, Grenoble INP-CNRS-UJF, BP 75, 38402 St. Martin d' Heres Cedex (France); Fressengeas, Claude; Lebyodkin, Mikhail; Taupin, Vincent [Laboratoire de Physique et Mecanique des Materiaux, Universite Paul Verlaine-Metz/CNRS, Ile du Saulcy, 57045 Metz Cedex (France); Bastie, Pierre [Laboratoire de Spectrometrie Physique, BP 87, 38402 St. Martin d' Heres Cedex (France)] [Institut Laue Langevin, BP 156, 38042 Grenoble Cedex 9 (France); Duval, Paul [Laboratoire de Glaciologie et Geophysique de l' Environnement-CNRS, 54 rue Moliere, 38402 St. Martin d' Heres (France)

    2010-03-15

    Hard X-ray diffraction experiments have provided evidence of a strongly heterogeneous distribution of dislocation densities along the axis of cylindrical ice single crystals oriented for basal slip in torsion creep. The dislocation arrangements showed a complex scale-invariant character, which was analyzed by means of statistical and multifractal techniques. A trend to decreasing autocorrelation of the dislocation distribution was observed as deformation proceeds. At low strain levels, long-range spatial correlations control the distribution, but short-range correlations in relation with cross-slip progressively prevail when strain increases. This trend was reproduced by a model based on field dislocation dynamics, a theory accounting for both long-range elastic interactions and short-range interactions through transport of dislocation densities.

  16. Characterizing short-range vs. long-range spatial correlations in dislocation distributions

    International Nuclear Information System (INIS)

    Chevy, Juliette; Fressengeas, Claude; Lebyodkin, Mikhail; Taupin, Vincent; Bastie, Pierre; Duval, Paul

    2010-01-01

    Hard X-ray diffraction experiments have provided evidence of a strongly heterogeneous distribution of dislocation densities along the axis of cylindrical ice single crystals oriented for basal slip in torsion creep. The dislocation arrangements showed a complex scale-invariant character, which was analyzed by means of statistical and multifractal techniques. A trend to decreasing autocorrelation of the dislocation distribution was observed as deformation proceeds. At low strain levels, long-range spatial correlations control the distribution, but short-range correlations in relation with cross-slip progressively prevail when strain increases. This trend was reproduced by a model based on field dislocation dynamics, a theory accounting for both long-range elastic interactions and short-range interactions through transport of dislocation densities.

  17. Short range correlations in the pion s-wave self-energy of pionic atoms

    OpenAIRE

    Salcedo, L. L.; Holinde, K.; Oset, E.; Schütz, C.

    1995-01-01

    We evaluate the contribution of second order terms to the pion-nucleus s-wave optical potential of pionic atoms generated by short range nuclear correlation. The corrections are sizeable because they involve the isoscalar s-wave $\\pi N$ amplitude for half off-shell situations where the amplitude is considerably larger than the on-shell one. In addition, the s-wave optical potential is reanalyzed by looking at all the different conventional contributions together lowest order, Pauli corrected ...

  18. Angular correlation between short-range. cap alpha. particles and. gamma. quanta

    Energy Technology Data Exchange (ETDEWEB)

    Kul' chitskii, L A; Latyshev, G D; Bulyginskii, D G

    1949-01-01

    Chang (Phys. Rev. 69, 60(1946); 70, 632(1946)) has found that the intensities of short-range ..cap alpha.. rays of Po and Ra are considerably higher than the values given by the Geiger-Nuttall law. This can be explained by assuming surface vibrations of ..cap alpha..-radioactive nuclei, which produce deformations and corresponding lowerings of the potential barrier in certain directions. In this case an angular correlation should exist between the short-range ..cap alpha.. ray and the accompanying ..gamma.. quantum. The authors checked this conclusion by applying the coincidence method to the ..cap alpha.. and ..gamma.. radiations of a mixture of RdTh (/sup 228/Th) and ThC (/sup 212/Bi). Maxima of coincidence numbers occur at angles 45 and 135 deg., with lesser maxima at 0 and 180 deg. Theoretical considerations show that in cases (like the one investigated) where the nuclear spin before and after the ..cap alpha.. and ..gamma.. emissions is zero, the angular correlations are uniquely determined whatever the deformation caused by the vibration; in other cases, the correlation depends on the kind of deformation. Therefore, it would be interesting to investigate the case of Pa, whose nuclear spin is not zero and the decay exhibits intensive groups of short-range ..cap alpha.. particles.

  19. Validation of a Short Form of an Indecision Test: The Vocational Assessment Test

    Science.gov (United States)

    Picard, France; Frenette, Éric; Guay, Frédéric; Labrosse, Julie

    2015-01-01

    The purpose of this research was to validate the scores of a short form of a new instrument, "l'Épreuve de décision vocationnelle, forme scolaire" (EDV-9S; vocational assessment test), which measures six indecision-related problems (lack of self-knowledge, lack of readiness, lack of method in decision making, lack of information,…

  20. Diffusion Tensor Imaging Correlates with Short-Term Myelopathy Outcome in Patients with Cervical Spondylotic Myelopathy.

    Science.gov (United States)

    Vedantam, Aditya; Rao, Avinash; Kurpad, Shekar N; Jirjis, Michael B; Eckardt, Gerald; Schmit, Brian D; Wang, Marjorie C

    2017-01-01

    To determine if spinal cord diffusion tensor imaging indexes correlate with short-term clinical outcome in patients undergoing elective cervical spine surgery for cervical spondylotic myelopathy (CSM). A prospective consecutive cohort study was performed in patients undergoing elective cervical spine surgery for CSM. After obtaining informed consent, patients with CSM underwent preoperative T2-weighted magnetic resonance imaging and diffusion tensor imaging of the cervical spine. Fractional anisotropy (FA) values at the level of maximum cord compression and at the noncompressed C1-2 level were calculated on axial images. We recorded the modified Japanese Orthopaedic Association (mJOA) scale, Neck Disability Index, and Short Form-36 physical functioning subscale scores for all patients preoperatively and 3 months postoperatively. Statistical analysis was performed to identify correlations between FA and clinical outcome scores. The study included 27 patients (mean age 54.5 years ± 1.9, 12 men). The mean postoperative changes in mJOA scale, Neck Disability Index, and Short Form-36 physical functioning subscale scores were 0.9 ± 0.3, -6.0 ± 1.9, and 3.4 ± 1.9. The mean FA at the level of maximum compression was significantly lower than the mean FA at the C1-2 level (0.5 vs. 0.55, P = 0.01). FA was significantly correlated with change in mJOA scale score (Pearson r = -0.42, P = 0.02). FA was significantly correlated with the preoperative mJOA scale score (Pearson r = 0.65, P < 0.001). Preoperative FA at the level of maximum cord compression significantly correlates with the 3-month change in mJOA scale score among patients with CSM. FA was also significantly associated with preoperative mJOA scale score and is a potential biomarker for spinal cord dysfunction in CSM. Published by Elsevier Inc.

  1. Visuospatial and Verbal Short-Term Memory Correlates of Vocabulary Ability in Preschool Children

    Science.gov (United States)

    Stokes, Stephanie F.; Klee, Thomas; Kornisch, Myriam; Furlong, Lisa

    2017-01-01

    Background: Recent studies indicate that school-age children's patterns of performance on measures of verbal and visuospatial short-term memory (STM) and working memory (WM) differ across types of neurodevelopmental disorders. Because these disorders are often characterized by early language delay, administering STM and WM tests to toddlers could…

  2. On the problem of nonsense correlations in allergological tests after routine extraction.

    Science.gov (United States)

    Rijckaert, G

    1981-01-01

    The influence of extraction procedures and culturing methods of material used for the preparation of allergenic extracts on correlation patterns found in allergological testing (skin test and RAST) was investigated. In our laboratory a short extraction procedure performed at O degrees C was used for Aspergillus repens. A. penicilloides, Wallemia sebi, their rearing media and non-inoculated medium. For the commercially available extracts from house dust, house-dust mite, pollen of Dactylus glomerata and A. penicilloides a longer procedure (several days) performed at room temperature was used. Statistical analysis showed a separation of all test results into two clusters, each cluster being composed of correlations between extracts from only one the manufacturers did not show any correlation. The correlations found between the short time incubated extracts of the xerophilic fungi and their rearing media could be explained by genetical and biochemical relationships between these fungi depending on ecological conditions. However, while the correlation found between house dust and house-dust mite is understandable, correlations found between long time incubated extracts from house-dust mite and D. glomerata or A. penicilloides may be nonsense correlations, that do not adequately describe the in vivo situation. The similarity of these extracts is presumably artificially created during extraction.

  3. The dependence of the nuclear charge form factor on short range correlations and surface fluctuation effects

    International Nuclear Information System (INIS)

    Massen, S. E.; Garistov, V. P.; Grypeos, M. E.

    1996-01-01

    The effects of nuclear surface fluctuations on harmonic oscillator elastic charge form factor of light nuclei are investigated, simultaneously approximating the short-range correlations through a Jastrow correlation factor. Inclusion of the surface fluctuation effects within this description, by truncating the cluster expansion at the two-body part, is found to improve somewhat the fit to the elastic charge form-factor of 16 O and 40 Ca. However, the convergence of the cluster expansion is expected to deteriorate. An additional finding is that surface-fluctuation correlations produce a drastic change in the asymptotic behaviour of the point-proton form-factor, which now falls off quite slowly (i.e. as const.q -4 ) at large values of the momentum transfer q

  4. Short-range second order screened exchange correction to RPA correlation energies

    Science.gov (United States)

    Beuerle, Matthias; Ochsenfeld, Christian

    2017-11-01

    Direct random phase approximation (RPA) correlation energies have become increasingly popular as a post-Kohn-Sham correction, due to significant improvements over DFT calculations for properties such as long-range dispersion effects, which are problematic in conventional density functional theory. On the other hand, RPA still has various weaknesses, such as unsatisfactory results for non-isogyric processes. This can in parts be attributed to the self-correlation present in RPA correlation energies, leading to significant self-interaction errors. Therefore a variety of schemes have been devised to include exchange in the calculation of RPA correlation energies in order to correct this shortcoming. One of the most popular RPA plus exchange schemes is the second order screened exchange (SOSEX) correction. RPA + SOSEX delivers more accurate absolute correlation energies and also improves upon RPA for non-isogyric processes. On the other hand, RPA + SOSEX barrier heights are worse than those obtained from plain RPA calculations. To combine the benefits of RPA correlation energies and the SOSEX correction, we introduce a short-range RPA + SOSEX correction. Proof of concept calculations and benchmarks showing the advantages of our method are presented.

  5. Vietnamese validation of the short version of Internet Addiction Test.

    Science.gov (United States)

    Tran, Bach Xuan; Mai, Hue Thi; Nguyen, Long Hoang; Nguyen, Cuong Tat; Latkin, Carl A; Zhang, Melvyn W B; Ho, Roger C M

    2017-12-01

    The main goal of the present study was to examine the psychometric properties of a Vietnamese version of the short-version of Internet Addiction Test (s-IAT) and to assess the relationship between s-IAT scores and demographics, health related qualify of life and perceived stress scores in young Vietnamese. The Vietnamese version of s-IAT was administered to a sample of 589 participants. Exploratory factor and reliability analyses were performed. Regression analysis was used to identify the associated factors. The two-factor model of Vietnamese version of s-IAT demonstrated good psychometric properties. The internal consistency of Factor 1 (loss of control/time management) was high (Cronbach's alpha = 0.82) and Factor 2 (craving/social problems) was satisfactory (Cronbach's alpha = 0.75). Findings indicated that 20.9% youths were addicted to the Internet. Regression analysis revealed significant associations between Internet addiction and having problems in self-care, lower quality of life and high perceived stress scores. The Vietnamese version of s-IAT is a valid and reliable instrument to assess IA in Vietnamese population. Due to the high prevalence of IA among Vietnamese youths, IA should be paid attention in future intervention programs. s-IAT can be a useful screening tool for IA to promptly inform and treat the IA among Vietnamese youths.

  6. A test of conformal invariance: Correlation functions on a disk

    International Nuclear Information System (INIS)

    Badke, R.; Rittenberg, V.; Ruegg, H.

    1985-06-01

    Using conformal invariance one can derive the correlation functions of a disk from those in the half-plane. The correlation function in the half-plane is determined by the 'small' conformal invariance up to an unknown function of one variable. By measuring through the Monte Carlo method the correlation function for two different configurations, the unknown function can be eliminated and one obtains a test of conformal invariance. It is shown that the Ising and the three state Potts model pass the test for very small lattices. (orig.)

  7. Timescale Correlation between Marine Atmospheric Exposure and Accelerated Corrosion Testing

    Science.gov (United States)

    Montgomery, Eliza L.; Calle, Luz Marina; Curran, Jerone C.; Kolody, Mark R.

    2011-01-01

    Evaluation of metal-based structures has long relied on atmospheric exposure test sites to determine corrosion resistance in marine environments. Traditional accelerated corrosion testing relies on mimicking the exposure conditions, often incorporating salt spray and ultraviolet (UV) radiation, and exposing the metal to continuous or cyclic conditions of the corrosive environment. Their success for correlation to atmospheric exposure is often a concern when determining the timescale to which the accelerated tests can be related. Accelerated laboratory testing, which often focuses on the electrochemical reactions that occur during corrosion conditions, has yet to be universally accepted as a useful tool in predicting the long term service life of a metal despite its ability to rapidly induce corrosion. Although visual and mass loss methods of evaluating corrosion are the standard and their use is imperative, a method that correlates timescales from atmospheric exposure to accelerated testing would be very valuable. This work uses surface chemistry to interpret the chemical changes occurring on low carbon steel during atmospheric and accelerated corrosion conditions with the objective of finding a correlation between its accelerated and long-term corrosion performance. The current results of correlating data from marine atmospheric exposure conditions at the Kennedy Space Center beachside corrosion test site, alternating seawater spray, and immersion in typical electrochemical laboratory conditions, will be presented. Key words: atmospheric exposure, accelerated corrosion testing, alternating seawater spray, marine, correlation, seawater, carbon steel, long-term corrosion performance prediction, X-ray photoelectron spectroscopy.

  8. HIV Testing in Recent College Students: Prevalence and Correlates

    Science.gov (United States)

    Caldeira, Kimberly M.; Singer, Barbara J.; O'Grady, Kevin E.; Vincent, Kathryn B.; Arria, Amelia M.

    2012-01-01

    Prevalence and correlates of HIV testing were examined in a sample of 957 unmarried recent college students in the United States. Participants were asked about HIV testing, past-six-months sexual activities, lifetime treatment for sexually transmitted infections (STI), past-year health service utilization, and DSM-IV criteria for alcohol and other…

  9. Short (

    NARCIS (Netherlands)

    Telleman, Gerdien; den Hartog, Laurens

    2013-01-01

    Aim: This systematic review assessed the implant survival rate of short (<10 mm) dental implants installed in partially edentulous patients. A case report of a short implant in the posterior region have been added. Materials and methods: A search was conducted in the electronic databases of MEDLINE

  10. Correlation structures in short-term variabilities of stock indices and exchange rates

    Science.gov (United States)

    Nakamura, Tomomichi; Small, Michael

    2007-09-01

    Financial data usually show irregular fluctuations and some trends. We investigate whether there are correlation structures in short-term variabilities (irregular fluctuations) among financial data from the viewpoint of deterministic dynamical systems. Our method is based on the small-shuffle surrogate method. The data we use are daily closing price of Standard & Poor's 500 and the volume, and daily foreign exchange rates, Euro/US Dollar (USD), British Pound/USD and Japanese Yen/USD. We found that these data are not independent.

  11. Short Range Correlations in Nuclei at Large xbj through Inclusive Quasi-Elastic Electron Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Ye, Zhihong [Univ. of Virginia, Charlottesville, VA (United States)

    2013-12-01

    The experiment, E08-014, in Hall-A at Jefferson Lab aims to study the short-range correlations (SRC) which are necessary to explain the nuclear strength absent in the mean field theory. The cross sections for 2H, 3He, 4He, 12C, 40Ca and 48Ca, were measured via inclusive quasi-elastic electron scattering from these nuclei in a Q2 range between 0.8 and 2.8 (GeV/c)2 for x>1. The cross section ratios of heavy nuclei to 2H were extracted to study two-nucleon SRC for 1

  12. Correlation between plaque control and gingival health using short and extended oral hygiene intervals.

    Science.gov (United States)

    De David, S C; Mário, T G; De Freitas, G C; Kantorski, K Z; Wikesjö, U M E; Moreira, Carlos Heitor Cunha

    2018-02-15

    To evaluate the correlation between dental plaque formation and gingival health in subjects performing high oral hygiene standards over short or extended intervals. Fifty-two non-dental students volunteered for this study. The subjects, trained to perform high oral hygiene standards, were randomized to perform oral hygiene at 12-, 24-, 48-, or 72-h interval over 30 days. The plaque index (PlI) and the gingival index (GI) were evaluated at baseline, 15, and 30 days. For the statistical analysis, oral hygiene intervals were collapsed into daily (12 and 24 h; G12/24) and extended (48 and 72 h; G48/72) intervals. Summary statistics (mean ± SD) and Spearman correlations between the PlI and the GI at baseline, 15, and 30 days were estimated. At baseline, correlation coefficients between PlI and GI were positive for both groups (r = 0.29 and r = 0.25). At day 15 and 30, correlation was maintained with similar baseline values for the G48/72 group. GI levels did not increase despite an increase in PlI for the G12/24 group, and the correlation was lower than that observed at baseline (r = 0.13 vs. r = 0.29). In subjects with high oral hygiene standards, the oral hygiene frequency governs the correlation between dental plaque formation and gingival health. Subjects performing high oral hygiene standards at daily intervals will maintain gingival health in difference to subjects using extended hygiene intervals. Subjects performing high oral hygiene standards at daily intervals will maintain gingival health in difference to subjects using extended hygiene intervals.

  13. Neural correlates of enhanced visual short-term memory for angry faces: an FMRI study.

    Directory of Open Access Journals (Sweden)

    Margaret C Jackson

    Full Text Available Fluid and effective social communication requires that both face identity and emotional expression information are encoded and maintained in visual short-term memory (VSTM to enable a coherent, ongoing picture of the world and its players. This appears to be of particular evolutionary importance when confronted with potentially threatening displays of emotion - previous research has shown better VSTM for angry versus happy or neutral face identities.Using functional magnetic resonance imaging, here we investigated the neural correlates of this angry face benefit in VSTM. Participants were shown between one and four to-be-remembered angry, happy, or neutral faces, and after a short retention delay they stated whether a single probe face had been present or not in the previous display. All faces in any one display expressed the same emotion, and the task required memory for face identity. We find enhanced VSTM for angry face identities and describe the right hemisphere brain network underpinning this effect, which involves the globus pallidus, superior temporal sulcus, and frontal lobe. Increased activity in the globus pallidus was significantly correlated with the angry benefit in VSTM. Areas modulated by emotion were distinct from those modulated by memory load.Our results provide evidence for a key role of the basal ganglia as an interface between emotion and cognition, supported by a frontal, temporal, and occipital network.

  14. Approaching Repetitive Short Circuit Tests on MW-Scale Power Modules by means of an Automatic Testing Setup

    DEFF Research Database (Denmark)

    Reigosa, Paula Diaz; Wang, Huai; Iannuzzo, Francesco

    2016-01-01

    An automatic testing system to perform repetitive short-circuit tests on megawatt-scale IGBT power modules is pre-sented and described in this paper, pointing out the advantages and features of such testing approach. The developed system is based on a non-destructive short-circuit tester, which has...

  15. Correlation between HRCT and pulmonary functional tests in cystic fibrosis

    International Nuclear Information System (INIS)

    Mastellari, Paola; Biggi, Simona; Lombardi, Alfonsa; Zompatori, Maurizio; Grzincich, Gianluigi; Pisi, Giovanna; Spaggiari, Cinzia

    2005-01-01

    Purpose. To compare the HRCT score by Oikonottlou and air trapping in expiratory scans with pulmonary functional tests and evaluate which radiological criteria are more useful to predict clinical impairment. Materials and methods. From January to September 2003, pulmonary HRCT study was performed in 37 patients (23 males), aged between 7 and 41 years, with cystic fibrosis. In the same day of CT examination they also received a complete functional evaluation. HRCT studies were evaluated by three radiologists blinded to the clinical data and were correlated with the lung function tests. Results. We obtained a high correlation (p=0.01) for two of the HRCT signs: extent of mucus plugging and mosaic perfusion pattern and all function tests. Discussion. Previous studies have demonstrated good correlation between lung function tests, in particular with FEV1 and HRCT signs. Our study differed from previous ones in that we analysed the correlation between lung function tests and with both single and combined CT criteria. Conclusion. Our results suggest that a simplified HRCT store could be useful to evaluate patients with cystic fibrosis [it

  16. Significance levels for studies with correlated test statistics.

    Science.gov (United States)

    Shi, Jianxin; Levinson, Douglas F; Whittemore, Alice S

    2008-07-01

    When testing large numbers of null hypotheses, one needs to assess the evidence against the global null hypothesis that none of the hypotheses is false. Such evidence typically is based on the test statistic of the largest magnitude, whose statistical significance is evaluated by permuting the sample units to simulate its null distribution. Efron (2007) has noted that correlation among the test statistics can induce substantial interstudy variation in the shapes of their histograms, which may cause misleading tail counts. Here, we show that permutation-based estimates of the overall significance level also can be misleading when the test statistics are correlated. We propose that such estimates be conditioned on a simple measure of the spread of the observed histogram, and we provide a method for obtaining conditional significance levels. We justify this conditioning using the conditionality principle described by Cox and Hinkley (1974). Application of the method to gene expression data illustrates the circumstances when conditional significance levels are needed.

  17. Correlations of Platooning Track Test and Wind Tunnel Data

    Energy Technology Data Exchange (ETDEWEB)

    Lammert, Michael P. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Kelly, Kenneth J. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Yanowitz, Janet [Ecoengineering, Sharonville, OH (United States)

    2018-02-02

    In this report, the National Renewable Energy Laboratory analyzed results from multiple, independent truck platooning projects to compare and contrast track test results with wind tunnel test results conducted by Lawrence Livermore National Laboratory (LLNL). Some highlights from the report include compiled data, and results from four independent SAE J1321 full-size track test campaigns that were compared to LLNL wind tunnel testing results. All platooning scenarios tested demonstrated significant fuel savings with good correlation relative to following distances, but there are still unanswered questions and clear opportunities for system optimization. NOx emissions showed improvements from NREL tests in 2014 to Auburn tests in 2015 with respect to J1321 platooning track testing of Peloton system. NREL evaluated data from Volpe's Naturalistic Study of Truck Following Behavior, which showed minimal impact of naturalistic background platooning. We found significant correlation between multiple track studies, wind tunnel tests, and computational fluid dynamics, but also showed that there is more to learn regarding close formation and longer-distance effects. We also identified potential areas for further research and development, including development of advanced aerodynamic designs optimized for platooning, measurement of platoon system performance in traffic conditions, impact of vehicle lateral offsets on platooning performance, and characterization of the national potential for platooning based on fleet operational characteristics.

  18. Correlation of alluvial deposits at the Nevada Test Site

    International Nuclear Information System (INIS)

    Grothaus, B.; Howard, N.

    1977-01-01

    Because characteristics of rock layers and problems in drilling must be studied before radioactive waste can be safely contained, an evaluation was made of methods for correlating alluvial deposits at Yucca Flat of the Nevada Test Site (NTS). Although correlation of Tertiary volcanic tuff beds at the NTS has been successfully achieved, correlation of stratigraphic zones in the overlying alluvium has posed technical difficulties. We have evaluated several methods for correlating alluvial deposits from drillholes, including electric resistivity logs (E logs), visual examination of sidewall samples and comparison of their carbonate (CO 2 ) content, downhole stereo photography for identifying debris flow deposits, caliche age-dating, and specific yield and permeability measurements of deposits. For predicting the thickness of zones having similar physical properties in the alluvium, E log measurements were found to be the most useful of these methods

  19. Statistical tests for power-law cross-correlated processes

    Science.gov (United States)

    Podobnik, Boris; Jiang, Zhi-Qiang; Zhou, Wei-Xing; Stanley, H. Eugene

    2011-12-01

    For stationary time series, the cross-covariance and the cross-correlation as functions of time lag n serve to quantify the similarity of two time series. The latter measure is also used to assess whether the cross-correlations are statistically significant. For nonstationary time series, the analogous measures are detrended cross-correlations analysis (DCCA) and the recently proposed detrended cross-correlation coefficient, ρDCCA(T,n), where T is the total length of the time series and n the window size. For ρDCCA(T,n), we numerically calculated the Cauchy inequality -1≤ρDCCA(T,n)≤1. Here we derive -1≤ρDCCA(T,n)≤1 for a standard variance-covariance approach and for a detrending approach. For overlapping windows, we find the range of ρDCCA within which the cross-correlations become statistically significant. For overlapping windows we numerically determine—and for nonoverlapping windows we derive—that the standard deviation of ρDCCA(T,n) tends with increasing T to 1/T. Using ρDCCA(T,n) we show that the Chinese financial market's tendency to follow the U.S. market is extremely weak. We also propose an additional statistical test that can be used to quantify the existence of cross-correlations between two power-law correlated time series.

  20. Correlation Based Testing for Passive Sonar Picture Rationalization

    National Research Council Canada - National Science Library

    Mellema, Garfield R

    2007-01-01

    .... The sample correlation coefficient, is a statistical measure of relatedness. This paper describes the application of a test based on that measure to compare tracks produced by a probabilistic data association filter from a set of towed array sonar data. Keywords.

  1. Taking serial correlation into account in tests of the mean

    International Nuclear Information System (INIS)

    Zwiers, F.W.; Storch, H. von

    1993-01-01

    The comparison of means derived from samples of noisy data is a standard part of climatology. When the data are not serially correlated the appropriate statistical tool for this task is usually the conventional Student's t-test. However, data frequently are serially correlated in climatological applications with the result that the t-tests in its standard form is not applicable. The usual solution to this problem is to scale the t-statistic by a factor which depends upon the equivalent sample size n e . We show, by means of simulations, that the revised t-test is often conservative (the actual significance level is smaller than the specified significance level) when the equivalent sample size is known. However, in most practical cases the equivalent sample size is not known. Then the test becomes liberal (the actual significance level is greater than the specified significance level). This systematic error becomes small when the true equivalent sample size is large (greater than approximately 30). We re-examine the difficulties inherent in difference of means tests when there is serial dependence. We provide guidelines for the application of the 'usual' t-test and propose two alternative tests which substantially improve upon the 'usual' t-test when samples are small. (orig.)

  2. Electrophysiological correlates of the retention of tones differing in timbre in auditory short-term memory.

    Science.gov (United States)

    Nolden, Sophie; Bermudez, Patrick; Alunni-Menichini, Kristelle; Lefebvre, Christine; Grimault, Stephan; Jolicoeur, Pierre

    2013-11-01

    We examined the electrophysiological correlates of retention in auditory short-term memory (ASTM) for sequences of one, two, or three tones differing in timbre but having the same pitch. We focused on event-related potentials (ERPs) during the retention interval and revealed a sustained fronto-central ERP component (most likely a sustained anterior negativity; SAN) that became more negative as memory load increased. Our results are consistent with recent ERP studies on the retention of pitch and suggest that the SAN reflects brain activity mediating the low-level retention of basic acoustic features in ASTM. The present work shows that the retention of timbre shares common features with the retention of pitch, hence supporting the notion that the retention of basic sensory features is an active process that recruits modality-specific brain areas. © 2013 Elsevier Ltd. All rights reserved.

  3. A New Theoretical Analysis of the Effects of Short Range Correlations in Inclusive Lepton Scattering

    Science.gov (United States)

    Benedetta Mezzetti, Chiara; Ciofi Degli Atti, Claudio

    2009-05-01

    Recently, evidence of short range correlations (SRC) has been provided by experimental data on inclusive lepton A(e, e')X scattering by the observation of a scaling behavior of the ratios of the cross sections on heavy nuclei to those on the deuteron and ^3He. Other attempts to get information on SRC rely on the concept of Y-scaling, whose interest has been renewed by new Jlab data. A new approach to Y-scaling, relying on the definition of a new relativistic scaling variable which incorporates the momentum dependence of the excitation energy of the (A - 1) system is presented, with the resulting scaling function being closely related to the longitudinal momentum distributions. Taking into account final state interaction effects, the new analysis of experimental data on nuclei, ranging from ^3He to Nuclear Matter, provides unique information on the nucleon momentum distributions and confirms the analysis in terms of cross section ratios.

  4. Dependence of Coulomb Sum Rule on the Short Range Correlation by Using Av18 Potential

    Science.gov (United States)

    Modarres, M.; Moeini, H.; Moshfegh, H. R.

    The Coulomb sum rule (CSR) and structure factor are calculated for inelastic electron scattering from nuclear matter at zero and finite temperature in the nonrelativistic limit. The effect of short-range correlation (SRC) is presented by using lowest order constrained variational (LOCV) method and the Argonne Av18 and Δ-Reid soft-core potentials. The effects of different potentials as well as temperature are investigated. It is found that the nonrelativistic version of Bjorken scaling approximately sets in at the momentum transfer of about 1.1 to 1.2 GeV/c and the increase of temperature makes it to decrease. While different potentials do not significantly change CSR, the SRC improves the Coulomb sum rule and we get reasonably close results to both experimental data and others theoretical predictions.

  5. Study on the correlation between long-term exposure tests and accelerated corrosion tests by the combined damage of salts

    International Nuclear Information System (INIS)

    Park, Sang Soon; Lee, Min Woo

    2014-01-01

    Interest in the durability assessment and structural performance has increased according to an increase of concrete structures in salt damage environment recent years. Reliable way ensuring the most accelerated corrosion test is a method of performing the rebar corrosion monitoring as exposed directly to the marine test site exposure. However, long-term exposure test has a disadvantage because of a long period of time. Therefore, many studies on reinforced concrete in salt damage environments have been developed as alternatives to replace this. However, accelerated corrosion test is appropriate to evaluate the critical chlorine concentration in the short term, but only accelerated test method, is not easy to get correct answer. Accuracy of correlation acceleration test depends on the period of the degree of exposure environments. Therefore, in this study, depending on the concrete mix material, by the test was performed on the basis of the composite degradation of the salt damage, and investigate the difference of corrosion initiation time of the rebar, and indoor corrosion time of the structure, of the marine environment of the actual environments were investigated. The correlation coefficient was derived in the experiment. Long-term exposure test was actually conducted in consideration of the exposure conditions submerged zone, splash zone and tidal zone. The accelerated corrosion tests were carried out by immersion conditions, and by the combined deterioration due to the carbonation and accelerated corrosion due to wet and dry condition

  6. Short-term consistency testing vs. long-term behavior

    International Nuclear Information System (INIS)

    Ebert, W.L.; Bakel, A.J.; Wolf, S.F.; Strachan, D.M.

    1997-01-01

    The authors conducted Product Consistency Tests (PCTs) with a surrogate low-activity waste (LAW) glass to (1) evaluate the possible use of various test conditions in a specification test for LAW waste forms, (2) measure the reproducibility of the test at low temperatures, and (3) determine if the rates calculated from 7-day PCTs bound the rates measured in PCT conducted for longer durations, which represent more advanced corrosion. The effects of temperature and pH on the dissolution rate in PCTs are much less than the effects observed in dilute solutions due to the buildup of dissolved glass components in the PCTs. The precision of replicate 7-day tests at 20 and 40 degrees C was limited by the analytical uncertainty. The dissolution rates at all temperatures decreased with the test duration initially. However, the dissolution rates in tests at 70 and 90 degrees C increased when certain alteration phases formed after about 100 and 500 days, respectively; the rates in some tests exceeded that measured in a 7-day PCT. While the 7-day PCT does not provide a bounding rate for this glass at 70 or 90 degrees C, tests for longer durations are needed to determine if a 7-day test provides a bounding rate at lower temperatures

  7. Structural study of liquids with strong short-range correlation in the atomic distribution

    International Nuclear Information System (INIS)

    Uzuki, Kenji

    1976-01-01

    Structure factors of liquids and amorphous solids having a relatively high degree of ordering in their short-range structures have been measured over a wide range of scattering vectors by means of the T-O-F neutron diffraction using epithermal pulsed neutrons generated by an electron linear accelerator. It has been shown in the case of liquid CS 2 that the size and shape of a molecule existing in the liquid phase are determined from the behaviour of the structure factor in the range of high scattering vectors, and that the structure factor in the region of low scattering vectors informs on inter-molecular orientational and center-center correlations in the liquid state. Moreover, based on highly resoluted radial distribution functions, a free rotating chain model has been discussed for chain molecules contained in liquid Se, and a splitting of the nearest neighbour Pd-Pd and Pd-Si correlation has been clearly found in the amorphous Pdsub(0.8) - Sisub(0.2) alloy. (orig./HK) [de

  8. Control and test software for IRAM WideX correlator

    International Nuclear Information System (INIS)

    Blanchet, S.; Broguiere, D.; Chavatte, P.; Morel, F.; Perrigouard, A.; Torres, M.

    2012-01-01

    IRAM is an international research institute for radio astronomy. It has designed a new correlator called WideX for the Plateau de Bure interferometer (an array of six 15-meter telescopes) in the French Alps. The device started its official service in February 2010. This correlator must be driven in real-time at 32 Hz for sending parameters and for data acquisition. With 3.67 million channels, distributed over 1792 dedicated chips, that produce a 1.87 Gbits/sec data output rate, the data acquisition and processing and also the automatic hardware-failure detection are big challenges for the software. This article presents the software that has been developed to drive and test the correlator. In particular it presents an innovative usage of a high speed optical link, initially developed for the CERN ALICE experiment, associated with real-time Linux (RTAI) to achieve our goals. (authors)

  9. Tests for nonlinearity in short stationary time series

    International Nuclear Information System (INIS)

    Chang, T.; Sauer, T.; Schiff, S.J.

    1995-01-01

    To compare direct tests for detecting determinism in chaotic time series, data from Henon, Lorenz, and Mackey--Glass equations were contaminated with various levels of additive colored noise. These data were analyzed with a variety of recently developed tests for determinism, and the results compared

  10. Short Report Challenges with targeted viral load testing for medical ...

    African Journals Online (AJOL)

    Challenges with targeted viral load testing 179. Malawi Medical ... targeted viral load (VL) testing for patients who have been on ART for at least .... Tuberculosis. 32. Community-acquired pneumonia. 17. Non-typhoidal Salmonella sepsis. 5. Bacterial meningitis. 5. Disseminated Kaposi sarcoma. 4. Cryptococcal meningitis. 4.

  11. Estimate of uncertainties correlated and no correlated associated to performance tests of activity meters

    International Nuclear Information System (INIS)

    Sousa, C.H.S.; Teixeira, G.J.; Peixoto, J.G.P.

    2014-01-01

    Activimeters should undergo performance for verifying the functionality tests as technical recommendations. This study estimated the associated expanded uncertainties uncorrelated to the results conducted on three instruments, two detectors with ionization chamber and one with Geiger Mueller tubes. For this we used a standard reference source and screened certified by the National Institute of Technology and Standardization. The methodology of this research was based on the protocols listed in the technical document of the International Atomic Energy Agency. Later two quantities were correlated presenting real correlation and improving expanded uncertainty 3.7%. (author)

  12. Motor competence assessment in children: convergent and discriminant validity between the BOT-2 Short Form and KTK testing batteries.

    Science.gov (United States)

    Fransen, Job; D'Hondt, Eva; Bourgois, Jan; Vaeyens, Roel; Philippaerts, Renaat M; Lenoir, Matthieu

    2014-06-01

    This study investigated convergent and discriminant validity between two motor competence assessment instruments in 2485 Flemish children: the Bruininks-Oseretsky Test of Motor Proficiency 2 Short Form (BOT-2 Short Form) and the KörperKoördinationsTest für Kinder (KTK). A Pearson correlation assessed the relationship between BOT-2 Short Form total, gross and fine motor composite scores and KTK Motor Quotient in three age cohorts (6-7, 8-9, 10-11 years). Crosstabs were used to measure agreement in classification in children scoring below percentile 5 and 15 and above percentile 85 and 95. Moderately strong positive (r=0.44-0.64) associations between BOT-2 total and gross motor composite scores and KTK Motor Quotient and weak positive correlations between BOT-2 Short Form fine motor composite and KTK Motor Quotient scores (r=0.25-0.37) were found. Levels of agreement were fair to moderate. Therefore, some proof of convergent and discriminant validity between BOT-2 Short Form and KTK was established in this study, underlining the notion that the evaluation of motor competence should not be based upon a single assessment instrument. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Correlated evolution of short wavelength sensitive photoreceptor sensitivity and color pattern in Lake Malawi cichlids

    Directory of Open Access Journals (Sweden)

    Michael J. Pauers

    2016-02-01

    Full Text Available For evolutionary ecologists, the holy grail of visual ecology is to establish an unambiguous link between photoreceptor sensitivity, the spectral environment, and the perception of specific visual stimuli (e.g., mates, food, predators, etc.. Due to the bright nuptial colors of the males, and the role female mate choice plays in their evolution, the haplochromine cichlid fishes of the African great lakes are favorite research subjects for such investigations. Despite this attention, current evidence is equivocal; while distinct correlations among photoreceptor sensitivity, photic environment, and male coloration exist in Lake Victorian haplochromines, attempts to find such correlations in Lake Malawian cichlids have failed. Lake Malawi haplochromines have a wide variability in their short-wavelength-sensitive photoreceptors, especially compared to their mid- and long-wavelength-sensitive photoreceptors; these cichlids also vary in the degree to which they express one of three basic color patterns (vertical bars, horizontal stripes, and solid patches of colors, each of which is likely used in a different form of communication. Thus, we hypothesize that, in these fishes, spectral sensitivity and color pattern have evolved in a correlated fashion to maximize visual communication; specifically, ultraviolet sensitivity should be found in vertically-barred species to promote ‘private’ communication, while striped species should be less likely to have ultraviolet sensitivity, since their color pattern carries ‘public’ information. Using phylogenetic independent contrasts, we found that barred species had strong sensitivity to ultraviolet wavelengths, but that striped species typically lacked sensitivity to ultraviolet light. Further, the only variable, even when environmental variables were simultaneously considered, that could predict ultraviolet sensitivity was color pattern. We also found that, using models of correlated evolution, color

  14. Testing general relativity at cosmological scales: Implementation and parameter correlations

    International Nuclear Information System (INIS)

    Dossett, Jason N.; Ishak, Mustapha; Moldenhauer, Jacob

    2011-01-01

    The testing of general relativity at cosmological scales has become a possible and timely endeavor that is not only motivated by the pressing question of cosmic acceleration but also by the proposals of some extensions to general relativity that would manifest themselves at large scales of distance. We analyze here correlations between modified gravity growth parameters and some core cosmological parameters using the latest cosmological data sets including the refined Cosmic Evolution Survey 3D weak lensing. We provide the parametrized modified growth equations and their evolution. We implement known functional and binning approaches, and propose a new hybrid approach to evolve the modified gravity parameters in redshift (time) and scale. The hybrid parametrization combines a binned redshift dependence and a smooth evolution in scale avoiding a jump in the matter power spectrum. The formalism developed to test the consistency of current and future data with general relativity is implemented in a package that we make publicly available and call ISiTGR (Integrated Software in Testing General Relativity), an integrated set of modified modules for the publicly available packages CosmoMC and CAMB, including a modified version of the integrated Sachs-Wolfe-galaxy cross correlation module of Ho et al. and a new weak-lensing likelihood module for the refined Hubble Space Telescope Cosmic Evolution Survey weak gravitational lensing tomography data. We obtain parameter constraints and correlation coefficients finding that modified gravity parameters are significantly correlated with σ 8 and mildly correlated with Ω m , for all evolution methods. The degeneracies between σ 8 and modified gravity parameters are found to be substantial for the functional form and also for some specific bins in the hybrid and binned methods indicating that these degeneracies will need to be taken into consideration when using future high precision data.

  15. Fourteen years of test experience with short-circuit withstand capability of large power transformers

    NARCIS (Netherlands)

    Smeets, R.P.P.; Paske, te L.H.

    2010-01-01

    Experience is reported of short-circuit testing of large power transformers during the past 14 years by KEMA in the Netherlands. In total, 119 transformers > 25 MVA participated in the survey. KEMA shows that at initial access to standard IEC short-circuit tests, 28% failed initially in a wide range

  16. Sixteen years of test experiences with short-circuit withstand capability of large power transformers

    NARCIS (Netherlands)

    Smeets, R.P.P.; Paske, te L.H.

    2012-01-01

    Experience is reported of short-circuit testing of large power transformers during the past 16 years by KEMA in the Netherlands. In total, 174 transformers > 25 MVA participated in the survey. KEMA shows that at initial access to standard IEC short-circuit tests, 24% failed initially in a wide range

  17. Kolmogorov-Smirnov test for spatially correlated data

    Science.gov (United States)

    Olea, R.A.; Pawlowsky-Glahn, V.

    2009-01-01

    The Kolmogorov-Smirnov test is a convenient method for investigating whether two underlying univariate probability distributions can be regarded as undistinguishable from each other or whether an underlying probability distribution differs from a hypothesized distribution. Application of the test requires that the sample be unbiased and the outcomes be independent and identically distributed, conditions that are violated in several degrees by spatially continuous attributes, such as topographical elevation. A generalized form of the bootstrap method is used here for the purpose of modeling the distribution of the statistic D of the Kolmogorov-Smirnov test. The innovation is in the resampling, which in the traditional formulation of bootstrap is done by drawing from the empirical sample with replacement presuming independence. The generalization consists of preparing resamplings with the same spatial correlation as the empirical sample. This is accomplished by reading the value of unconditional stochastic realizations at the sampling locations, realizations that are generated by simulated annealing. The new approach was tested by two empirical samples taken from an exhaustive sample closely following a lognormal distribution. One sample was a regular, unbiased sample while the other one was a clustered, preferential sample that had to be preprocessed. Our results show that the p-value for the spatially correlated case is always larger that the p-value of the statistic in the absence of spatial correlation, which is in agreement with the fact that the information content of an uncorrelated sample is larger than the one for a spatially correlated sample of the same size. ?? Springer-Verlag 2008.

  18. Relationship Between Short Sleep Duration and Preseason Concussion Testing.

    Science.gov (United States)

    Silverberg, Noah D; Berkner, Paul D; Atkins, Joseph E; Zafonte, Ross; Iverson, Grant L

    2016-05-01

    Baseline, preseason assessment of cognition, symptoms, and balance has been recommended as part of a comprehensive sport concussion management program. We examined the relationship between sleep and baseline test results. We hypothesized that adolescents who slept fewer hours the night before would report more symptoms and perform more poorly on cognitive testing than students who had a full night sleep. Cross-sectional observation study. Preseason concussion testing for high school athletes. A large sample (n = 2928) of student athletes from Maine, USA, between the ages of 13 and 18 years completed preseason testing. Participants with developmental problems, a history of treatment for neurological or psychiatric problems, recent concussion, or 3 or more prior concussions were excluded. Athletes were divided into 4 groups based on their sleep duration the night before testing. Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT; ImPACT Applications, Inc, Pittsburgh, PA) cognitive composite scores and the embedded Post-Concussion Symptom Scale. Sleep was not related to any ImPACT cognitive composite score, after covarying for age and controlling for multiple comparisons. In contrast, there were sleep duration, sex, and sleep duration by sex effects on the Post-Concussion Symptom Scale. The effect of sleep duration on symptom reporting was more pronounced in girls. Supplementary analyses suggested that sleep insufficiency was associated with a diverse array of postconcussion-like symptoms. Poor sleep the night before baseline or postinjury testing may be an important confound when assessing postconcussion symptoms. Girls may be more vulnerable to experiencing and reporting symptoms following insufficient sleep. Clinicians should routinely ask how the athlete slept the night before preseason baseline testing and consider deferring the symptom assessment or later retesting athletes who slept poorly.

  19. Recurrence of gastroesophageal reflux disease correlated with a short dinner-to-bedtime interval.

    Science.gov (United States)

    Yang, Jae Hoon; Kang, Ho Suk; Lee, Sun-Young; Kim, Jeong Hwan; Sung, In-Kyung; Park, Hyung Seok; Shim, Chan Sup; Jin, Choon Jo

    2014-04-01

    Gastroesophageal reflux disease (GERD) can be classified into erosive reflux disease (ERD) and nonerosive gastroesophageal reflux disease (NERD). We aimed to compare the recurrence rates of ERD and NERD and determine the risk factors related to the recurrence. This prospective study comprised 337 consecutive adults who completed questionnaires on their GERD symptoms, height, weight, sleeping position, dinner time, and bedtime. During upper gastrointestinal endoscopy, the presence of a hiatal hernia and mucosal breaks in the low esophagus, esophageal length (the distance between the Z-line and the incisors), and the esophageal length-to-height ratio were recorded. Recurrence was diagnosed when the patient required additional proton pump inhibitor medication after initial recovery with 4-8 weeks of treatment. Recurrence was experienced by 47 (26.0%) of 181 GERD patients. The recurrence rate did not differ between the 48 ERD (27.1%) and 133 NERD (25.6%) patients (P = 0.849). Of the various factors studied, recurrence was found to be correlated with a dinner-to-bedtime interval of less than 3 h (P = 0.002), globus sensation (P = 0.031), and old age (P = 0.047). Logistic regression analysis revealed that a short interval between dinner and bedtime was the only factor significantly related to the recurrence (P = 0.002). Both ERD and NERD patients who sleep within 3 h after eating have a higher risk of GERD recurrence. Our findings highlight the impact of a short dinner-to-bedtime interval on the recurrence of GERD (ClinicalTrials.gov ID: KCT0000134). © 2013 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  20. Sequential accelerated tests: Improving the correlation of accelerated tests to module performance in the field

    Science.gov (United States)

    Felder, Thomas; Gambogi, William; Stika, Katherine; Yu, Bao-Ling; Bradley, Alex; Hu, Hongjie; Garreau-Iles, Lucie; Trout, T. John

    2016-09-01

    DuPont has been working steadily to develop accelerated backsheet tests that correlate with solar panels observations in the field. This report updates efforts in sequential testing. Single exposure tests are more commonly used and can be completed more quickly, and certain tests provide helpful predictions of certain backsheet failure modes. DuPont recommendations for single exposure tests are based on 25-year exposure levels for UV and humidity/temperature, and form a good basis for sequential test development. We recommend a sequential exposure of damp heat followed by UV then repetitions of thermal cycling and UVA. This sequence preserves 25-year exposure levels for humidity/temperature and UV, and correlates well with a large body of field observations. Measurements can be taken at intervals in the test, although the full test runs 10 months. A second, shorter sequential test based on damp heat and thermal cycling tests mechanical durability and correlates with loss of mechanical properties seen in the field. Ongoing work is directed toward shorter sequential tests that preserve good correlation to field data.

  1. Correlation analysis for forced vibration test of the Hualien large scale seismic test (LSST) program

    International Nuclear Information System (INIS)

    Sugawara, Y.; Sugiyama, T.; Kobayashi, T.; Yamaya, H.; Kitamura, E.

    1995-01-01

    The correlation analysis for a forced vibration test of a 1/4-scale containment SSI test model constructed in Hualien, Taiwan was carried out for the case of after backfilling. Prior to this correlation analysis, the structural properties were revised to adjust the calculated fundamental frequency in the fixed base condition to that derived from the test results. A correlation analysis was carried out using the Lattice Model which was able to estimate the soil-structure effects with embedment. The analysis results coincide well with test results and it is concluded that the mathematical soil-structure interaction model established by the correlation analysis is efficient in estimating the dynamic soil-structure interaction effect with embedment. This mathematical model will be applied as a basic model for simulation analysis of earthquake observation records. (author). 3 refs., 12 figs., 2 tabs

  2. Differences in the neural correlates of frontal lobe tests.

    Science.gov (United States)

    Matsuoka, Teruyuki; Kato, Yuka; Imai, Ayu; Fujimoto, Hiroshi; Shibata, Keisuke; Nakamura, Kaeko; Yamada, Kei; Narumoto, Jin

    2018-01-01

    The Executive Interview (EXIT25), the executive clock-drawing task (CLOX1), and the Frontal Assessment Battery (FAB) are used to assess executive function at the bedside. These tests assess distinct psychometric properties. The aim of this study was to examine differences in the neural correlates of the EXIT25, CLOX1, and FAB based on magnetic resonance imaging. Fifty-eight subjects (30 with Alzheimer's disease, 10 with mild cognitive impairment, and 18 healthy controls) participated in this study. Multiple regression analyses were performed to examine the brain regions correlated with the EXIT25, CLOX1, and FAB scores. Age, gender, and years of education were included as covariates. Statistical thresholds were set to uncorrected P-values of 0.001 at the voxel level and 0.05 at the cluster level. The EXIT25 score correlated inversely with the regional grey matter volume in the left lateral frontal lobe (Brodmann areas 6, 9, 44, and 45). The CLOX1 score correlated positively with the regional grey matter volume in the right orbitofrontal cortex (Brodmann area 11) and the left supramarginal gyrus (Brodmann area 40). The FAB score correlated positively with the regional grey matter volume in the right precentral gyrus (Brodmann area 6). The left lateral frontal lobe (Brodmann area 9) and the right lateral frontal lobe (Brodmann area 46) were identified as common brain regions that showed association with EXIT25, CLOX1, and FAB based only a voxel-level threshold. The results of this study suggest that the EXIT25, CLOX1, and FAB may be associated with the distinct neural correlates of the frontal cortex. © 2018 Japanese Psychogeriatric Society.

  3. Short-Cut Estimators of Criterion-Referenced Test Consistency.

    Science.gov (United States)

    Brown, James Dean

    1990-01-01

    Presents simplified methods for deriving estimates of the consistency of criterion-referenced, English-as-a-Second-Language tests, including (1) the threshold loss agreement approach using agreement or kappa coefficients, (2) the squared-error loss agreement approach using the phi(lambda) dependability approach, and (3) the domain score…

  4. Hall Thruster Thermal Modeling and Test Data Correlation

    Science.gov (United States)

    Myers, James; Kamhawi, Hani; Yim, John; Clayman, Lauren

    2016-01-01

    The life of Hall Effect thrusters are primarily limited by plasma erosion and thermal related failures. NASA Glenn Research Center (GRC) in cooperation with the Jet Propulsion Laboratory (JPL) have recently completed development of a Hall thruster with specific emphasis to mitigate these limitations. Extending the operational life of Hall thursters makes them more suitable for some of NASA's longer duration interplanetary missions. This paper documents the thermal model development, refinement and correlation of results with thruster test data. Correlation was achieved by minimizing uncertainties in model input and recognizing the relevant parameters for effective model tuning. Throughout the thruster design phase the model was used to evaluate design options and systematically reduce component temperatures. Hall thrusters are inherently complex assemblies of high temperature components relying on internal conduction and external radiation for heat dispersion and rejection. System solutions are necessary in most cases to fully assess the benefits and/or consequences of any potential design change. Thermal model correlation is critical since thruster operational parameters can push some components/materials beyond their temperature limits. This thruster incorporates a state-of-the-art magnetic shielding system to reduce plasma erosion and to a lesser extend power/heat deposition. Additionally a comprehensive thermal design strategy was employed to reduce temperatures of critical thruster components (primarily the magnet coils and the discharge channel). Long term wear testing is currently underway to assess the effectiveness of these systems and consequently thruster longevity.

  5. A facility to test short superconducting accelerator magnets at Fermilab

    International Nuclear Information System (INIS)

    Lamm, M.J.; Hess, C.; Lewis, D.; Jaffery, T.; Kinney, W.; Ozelis, J.P.; Strait, J.; Butteris, J.; McInturff, A.D.; Coulter, K.J.

    1992-10-01

    During the past four years the Superconducting Magnet R ampersand D facility at Fermilab (Lab 2) has successfully tested superconducting dipole, quadrupole, and correction coil magnets less than 2 meters in length for the SSC project and the Tevatron D0/B0 Low-β Insertion. During this time several improvements have been made to the facility that have greatly enhanced its magnet testing capabilities. Among the upgrades have been a new rotating coil and data acquisition system for measuring magnetic fields, a controlled flow liquid helium transfer line using an electronically actuated cryo valve, and stand-alone systems for measuring AC loss and training low current Tevatron correction coil packages. A description of the Lab 2 facilities is presented

  6. Test-Retest Reliability of the Short-Form Survivor Unmet Needs Survey.

    Science.gov (United States)

    Taylor, Karen; Bulsara, Max; Monterosso, Leanne

    2018-01-01

    Reliable and valid needs assessment measures are important assessment tools in cancer survivorship care. A new 30-item short-form version of the Survivor Unmet Needs Survey (SF-SUNS) was developed and validated with cancer survivors, including hematology cancer survivors; however, test-retest reliability has not been established. The objective of this study was to assess the test-retest reliability of the SF-SUNS with a cohort of lymphoma survivors ( n = 40). Test-retest reliability of the SF-SUNS was conducted at two time points: baseline (time 1) and 5 days later (time 2). Test-retest data were collected from lymphoma cancer survivors ( n = 40) in a large tertiary cancer center in Western Australia. Intraclass correlation analyses compared data at time 1 (baseline) and time 2 (5 days later). Cronbach's alpha analyses were performed to assess the internal consistency at both time points. The majority (23/30, 77%) of items achieved test-retest reliability scores 0.45-0.74 (fair to good). A high degree of overall internal consistency was demonstrated (time 1 = 0.92, time 2 = 0.95), with scores 0.65-0.94 across subscales for both time points. Mixed test-retest reliability of the SF-SUNS was established. Our results indicate the SF-SUNS is responsive to the changing needs of lymphoma cancer survivors. Routine use of cancer survivorship specific needs-based assessments is required in oncology care today. Nurses are well placed to administer these assessments and provide tailored information and resources. Further assessment of test-retest reliability in hematology and other cancer cohorts is warranted.

  7. Interplay between short-range correlated disorder and Coulomb interaction in nodal-line semimetals

    Science.gov (United States)

    Wang, Yuxuan; Nandkishore, Rahul M.

    2017-09-01

    In nodal-line semimetals, Coulomb interactions and short-range correlated disorder are both marginal perturbations to the clean noninteracting Hamiltonian. We analyze their interplay using a weak-coupling renormalization group approach. In the clean case, the Coulomb interaction has been found to be marginally irrelevant, leading to Fermi liquid behavior. We extend the analysis to incorporate the effects of disorder. The nodal line structure gives rise to kinematical constraints similar to that for a two-dimensional Fermi surface, which plays a crucial role in the one-loop renormalization of the disorder couplings. For a twofold degenerate nodal loop (Weyl loop), we show that disorder flows to strong coupling along a unique fixed trajectory in the space of symmetry inequivalent disorder couplings. Along this fixed trajectory, all symmetry inequivalent disorder strengths become equal. For a fourfold degenerate nodal loop (Dirac loop), disorder also flows to strong coupling, however, the strengths of symmetry inequivalent disorder couplings remain different. We show that feedback from disorder reverses the sign of the beta function for the Coulomb interaction, causing the Coulomb interaction to flow to strong coupling as well. However, the Coulomb interaction flows to strong coupling asymptotically more slowly than disorder. Extrapolating our results to strong coupling, we conjecture that at low energies nodal line semimetals should be described by a noninteracting nonlinear sigma model. We discuss the relation of our results with possible many-body localization at zero temperatures in such materials.

  8. Electronic structure of disordered binary alloys with short range correlation in Bethe lattice

    International Nuclear Information System (INIS)

    Moreno, I.F.

    1987-01-01

    The determination of the electronic structure of a disordered material along the tight-binding model when applied to a Bethe lattice. The diagonal as well as off-diagonal disorder, are considered. The coordination number on the Bethe is fixed lattice to four (Z=4) that occurs in most compound semiconductors. The main proposal was to study the conditions under which a relatively simple model of a disordered material, i.e, a binary alloy, could account for the basic properties of transport or more specifically for the electronic states in such systems. By using a parametrization of the pair probability the behaviour of the electronic density of states (DOS) for different values of the short range order parameter, σ, which makes possible to treat the segregated, random and alternating cases, was analysed. In solving the problem via the Green function technique in the Wannier representation a linear chain of atoms was considered and using the solution of such a 1-D system the problem of the Bethe lattice which is constructed using such renormalized chains as elements, was solved. The results indicate that the obtained DOS are strongly dependent on the correlation assumed for the occupancy in the lattice. (author) [pt

  9. Measurement of transparency ratios for protons from short-range correlated pairs

    Science.gov (United States)

    Hen, O.; Hakobyan, H.; Shneor, R.; Piasetzky, E.; Weinstein, L. B.; Brooks, W. K.; May-Tal Beck, S.; Gilad, S.; Korover, I.; Beck, A.; Adhikari, K. P.; Aghasyan, M.; Amaryan, M. J.; Anefalos Pereira, S.; Arrington, J. R.; Baghdasaryan, H.; Ball, J.; Battaglieri, M.; Batourine, V.; Bedlinskiy, I.; Biselli, A. S.; Bono, J.; Boiarinov, S.; Briscoe, W. J.; Burkert, V. D.; Carman, D. S.; Celentano, A.; Chandavar, S.; Cole, P. L.; Contalbrigo, M.; Crede, V.; D'Angelo, A.; Dashyan, N.; De Vita, R.; De Sanctis, E.; Deur, A.; Djalali, C.; Dodge, G. E.; Doughty, D.; Dupre, R.; Egiyan, H.; El Alaoui, A.; El Fassi, L.; Eugenio, P.; Fedotov, G.; Fegan, S.; Fleming, J. A.; Gabrielyan, M. Y.; Gevorgyan, N.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Goetz, J. T.; Gohn, W.; Golovatch, E.; Gothe, R. W.; Griffioen, K. A.; Guo, L.; Hafidi, K.; Harrison, N.; Heddle, D.; Hicks, K.; Holtrop, M.; Hyde, C. E.; Ilieva, Y.; Ireland, D. G.; Ishkhanov, B. S.; Isupov, E. L.; Jo, H. S.; Joo, K.; Keller, D.; Khandaker, M.; Khetarpal, P.; Kim, A.; Klein, F. J.; Koirala, S.; Kubarovsky, A.; Kubarovsky, V.; Kuhn, S. E.; Livingston, K.; Lu, H. Y.; MacGregor, I. J. D.; Martinez, D.; Mayer, M.; McKinnon, B.; Mineeva, T.; Mokeev, V.; Montgomery, R. A.; Moutarde, H.; Munevar, E.; Munoz Camacho, C.; Mustapha, B.; Nadel-Turonski, P.; Nasseripour, R.; Niccolai, S.; Niculescu, G.; Niculescu, I.; Osipenko, M.; Ostrovidov, A. I.; Pappalardo, L. L.; Paremuzyan, R.; Park, K.; Park, S.; Pasyuk, E.; Phelps, E.; Phillips, J. J.; Pisano, S.; Pivnyuk, N.; Pogorelko, O.; Pozdniakov, S.; Price, J. W.; Procureur, S.; Protopopescu, D.; Puckett, A. J. R.; Raue, B. A.; Rimal, D.; Ripani, M.; Ritchie, B. G.; Rosner, G.; Rossi, P.; Sabatié, F.; Saini, M. S.; Schott, D.; Schumacher, R. A.; Seraydaryan, H.; Sharabian, Y. G.; Smith, G. D.; Sober, D. I.; Sokhan, D.; Stepanyan, S. S.; Stepanyan, S.; Strauch, S.; Taiuti, M.; Tang, W.; Taylor, C. E.; Tian, Ye; Tkachenko, S.; Ungaro, M.; Vernarsky, B.; Vlassov, A.; Voskanyan, H.; Voutier, E.; Walford, N. K.; Watts, D. P.; Wood, M. H.; Zachariou, N.; Zana, L.; Zhang, J.; Zheng, X.; Zonta, I.

    2013-05-01

    Nuclear transparency, Tp (A), is a measure of the average probability for a struck proton to escape the nucleus without significant re-interaction. Previously, nuclear transparencies were extracted for quasi-elastic A (e ,e‧ p) knockout of protons with momentum below the Fermi momentum, where the spectral functions are well known. In this Letter we extract a novel observable, the transparency ratio, Tp (A) /Tp(12 C), for knockout of high-missing-momentum protons from the breakup of short-range correlated pairs (2N-SRC) in Al, Fe and Pb nuclei relative to C. The ratios were measured at momentum transfer Q2 ⩾ 1.5(GeV /c) 2 and xB ⩾ 1.2 where the reaction is expected to be dominated by electron scattering from 2N-SRC. The transparency ratios of the knocked-out protons coming from 2N-SRC breakup are 20-30% lower than those of previous results for low missing momentum. They agree with Glauber calculations and agree with renormalization of the previously published transparencies as proposed by recent theoretical investigations. The new transparencies scale as A - 1 / 3, which is consistent with dominance of scattering from nucleons at the nuclear surface.

  10. Reduced short interval cortical inhibition correlates with atomoxetine response in children with attention-deficit hyperactivity disorder (ADHD).

    Science.gov (United States)

    Chen, Tina H; Wu, Steve W; Welge, Jeffrey A; Dixon, Stephan G; Shahana, Nasrin; Huddleston, David A; Sarvis, Adam R; Sallee, Floyd R; Gilbert, Donald L

    2014-12-01

    Clinical trials in children with attention-deficit hyperactivity disorder (ADHD) show variability in behavioral responses to the selective norepinephrine reuptake inhibitor atomoxetine. The objective of this study was to determine whether transcranial magnetic stimulation-evoked short interval cortical inhibition might be a biomarker predicting, or correlating with, clinical atomoxetine response. At baseline and after 4 weeks of atomoxetine treatment in 7- to 12-year-old children with ADHD, transcranial magnetic stimulation short interval cortical inhibition was measured, blinded to clinical improvement. Primary analysis was by multivariate analysis of covariance. Baseline short interval cortical inhibition did not predict clinical responses. However, paradoxically, after 4 weeks of atomoxetine, mean short interval cortical inhibition was reduced 31.9% in responders and increased 6.1% in nonresponders (analysis of covariance t 41 = 2.88; P = .0063). Percentage reductions in short interval cortical inhibition correlated with reductions in the ADHD Rating Scale (r = 0.50; P = .0005). In children ages 7 to 12 years with ADHD treated with atomoxetine, improvements in clinical symptoms are correlated with reductions in motor cortex short interval cortical inhibition. © The Author(s) 2014.

  11. A comparison of computerized adaptive testing and fixed-length short forms for the Prosthetic Limb Users Survey of Mobility (PLUS-MTM).

    Science.gov (United States)

    Amtmann, Dagmar; Bamer, Alyssa M; Kim, Jiseon; Bocell, Fraser; Chung, Hyewon; Park, Ryoungsun; Salem, Rana; Hafner, Brian J

    2017-09-01

    New health status instruments can be administered by computerized adaptive test or short forms. The Prosthetic Limb Users Survey of Mobility (PLUS-M TM ) is a self-report measure of mobility for prosthesis users with lower limb loss. This study used the PLUS-M to examine advantages and disadvantages of computerized adaptive test and short forms. To compare scores obtained from computerized adaptive test to scores obtained from fixed-length short forms (7-item and 12-item) in order to provide guidance to researchers and clinicians on how to select the best form of administration for different uses. Cross-sectional, observational study. Individuals with lower limb loss completed the PLUS-M by computerized adaptive test and short forms. Administration time, correlations between the scores, and standard errors were compared. Scores and standard errors from the computerized adaptive test, 7-item short form, and 12-item short form were highly correlated and all forms of administration were efficient. Computerized adaptive test required less time to administer than either paper or electronic short forms; however, time savings were minimal compared to the 7-item short form. Results indicate that the PLUS-M computerized adaptive test is most efficient, and differences in scores between administration methods are minimal. The main advantage of the computerized adaptive test was more reliable scores at higher levels of mobility compared to short forms. Clinical relevance Health-related item banks, like the Prosthetic Limb Users Survey of Mobility (PLUS-M TM ), can be administered by computerized adaptive testing (CAT) or as fixed-length short forms (SFs). Results of this study will help clinicians and researchers decide whether they should invest in a CAT administration system or whether SFs are more appropriate.

  12. Neural Correlates of Visual Short-term Memory Dissociate between Fragile and Working Memory Representations.

    Science.gov (United States)

    Vandenbroucke, Annelinde R E; Sligte, Ilja G; de Vries, Jade G; Cohen, Michael X; Lamme, Victor A F

    2015-12-01

    Evidence is accumulating that the classic two-stage model of visual STM (VSTM), comprising iconic memory (IM) and visual working memory (WM), is incomplete. A third memory stage, termed fragile VSTM (FM), seems to exist in between IM and WM [Vandenbroucke, A. R. E., Sligte, I. G., & Lamme, V. A. F. Manipulations of attention dissociate fragile visual STM from visual working memory. Neuropsychologia, 49, 1559-1568, 2011; Sligte, I. G., Scholte, H. S., & Lamme, V. A. F. Are there multiple visual STM stores? PLoS One, 3, e1699, 2008]. Although FM can be distinguished from IM using behavioral and fMRI methods, the question remains whether FM is a weak expression of WM or a separate form of memory with its own neural signature. Here, we tested whether FM and WM in humans are supported by dissociable time-frequency features of EEG recordings. Participants performed a partial-report change detection task, from which individual differences in FM and WM capacity were estimated. These individual FM and WM capacities were correlated with time-frequency characteristics of the EEG signal before and during encoding and maintenance of the memory display. FM capacity showed negative alpha correlations over peri-occipital electrodes, whereas WM capacity was positively related, suggesting increased visual processing (lower alpha) to be related to FM capacity. Furthermore, FM capacity correlated with an increase in theta power over central electrodes during preparation and processing of the memory display, whereas WM did not. In addition to a difference in visual processing characteristics, a positive relation between gamma power and FM capacity was observed during both preparation and maintenance periods of the task. On the other hand, we observed that theta-gamma coupling was negatively correlated with FM capacity, whereas it was slightly positively correlated with WM. These data show clear differences in the neural substrates of FM versus WM and suggest that FM depends more on

  13. Short-duration Electron Precipitation Studied by Test Particle Simulation

    Directory of Open Access Journals (Sweden)

    Jaejin Lee

    2015-12-01

    Full Text Available Energy spectra of electron microbursts from 170 keV to 340 keV have been measured by the solid-state detectors aboard the low-altitude (680 km polar-orbiting Korean STSAT-1 (Science and Technology SATellite. These measurements have revealed two important characteristics unique to the microbursts: (1 They are produced by a fast-loss cone-filling process in which the interaction time for pitch-angle scattering is less than 50 ms and (2 The e-folding energy of the perpendicular component is larger than that of the parallel component, and the loss cone is not completely filled by electrons. To understand how wave-particle interactions could generate microbursts, we performed a test particle simulation and investigated how the waves scattered electron pitch angles within the timescale required for microburst precipitation. The application of rising-frequency whistler-mode waves to electrons of different energies moving in a dipole magnetic field showed that chorus magnetic wave fields, rather than electric fields, were the main cause of microburst events, which implied that microbursts could be produced by a quasi-adiabatic process. In addition, the simulation results showed that high-energy electrons could resonate with chorus waves at high magnetic latitudes where the loss cone was larger, which might explain the decreased e-folding energy of precipitated microbursts compared to that of trapped electrons.

  14. Development of a Short Form of the Boston Naming Test for Individuals with Aphasia

    Science.gov (United States)

    del Toro, Christina M.; Bislick, Lauren P.; Comer, Matthew; Velozo, Craig; Romero, Sergio; Rothi, Leslie J. Gonzalez; Kendall, Diane L.

    2011-01-01

    Purpose: The purpose of this study was to develop a short form of the Boston Naming Test (BNT; Kaplan, Goodglass, & Weintraub, 2001) for individuals with aphasia and compare it with 2 existing short forms originally analyzed with responses from people with dementia and neurologically healthy adults. Method: Development of the new BNT-Aphasia Short…

  15. Thirteen years test experience with short-circuit withstand capability of large power transformers

    NARCIS (Netherlands)

    Smeets, R.P.P.; Paske, te L.H.; Leufkens, P.P.; Fogelberg, T.

    2009-01-01

    The ability to withstand a short circuit is recognised more and more as an essential characteristic of power transformers. IEC and IEEE Standards, as well as other national standards specify short-circuit testing and how to check the withstand capability. Unfortunately, however, there is extensive

  16. EEG correlates of visual short-term memory as neuro-cognitive endophenotypes of ADHD.

    Science.gov (United States)

    Wiegand, Iris; Hennig-Fast, Kristina; Kilian, Beate; Müller, Hermann J; Töllner, Thomas; Möller, Hans-Jürgen; Engel, Rolf R; Finke, Kathrin

    2016-05-01

    Attention deficit hyperactivity disorder (ADHD) frequently persists into adulthood. A reduction in visual short-term memory (vSTM) storage capacity was recently suggested as a potential neuro-cognitive endophenotype, i.e., a testable marker of an individual's liability for developing ADHD. This study aimed at identifying markers of the brain abnormalities underlying vSTM reductions in adult ADHD. We combined behavioral parameter-based assessment with electrophysiology in groups of adult ADHD patients and healthy age-matched controls. Amplitudes of ERP markers of vSTM storage capacity, the contralateral delay activity (CDA) and the P3b, were analyzed according to (i) differences between individuals with higher vs. lower storage capacity K and (ii) differences between ADHD patients and control participants. We replicated the finding of reduced storage capacity in adult ADHD. Across groups, individuals with higher relative to lower storage capacity showed a larger CDA and P3b. We further found differences between the patient and control groups in the ERPs: The CDA amplitude was attenuated in an early time window for ADHD patients compared to control participants, and was negatively correlated with ADHD patients' symptom severity ratings. Furthermore, the P3b was larger in ADHD patients relative to control participants. These electrophysiological findings indicate altered brain mechanisms underlying visual storage capacity in ADHD, which are characterized by deficient encoding and maintenance, and increased recruitment of control processes. Accordingly, (quantifiable) ERP markers of vSTM in adult ADHD bear candidacy as neuro-cognitive endophenotypes of the disease. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Short-range structure of barium tellurite glasses and its correlation with stress-optic response

    Science.gov (United States)

    Kaur, Amarjot; Khanna, Atul; Fábián, Margit

    2018-06-01

    The atomic parameters of metal ion-oxygen speciation such as bond-lengths and nearest neighbor distances for Ba-O, Te-O and O-O pairs, co-ordination numbers and bond angle distributions for O-Ba-O, O-Te-O and O-O-O linkages are determined by neutron diffraction and Reverse Monte Carlo simulations on the series of xBaO-(100-x)TeO2 glasses containing 10, 15 and 20 mol% BaO. The glass network depolymerizes and the average Te-O co-ordination number decreases from 3.60 ± 0.02 to 3.48 ± 0.02 with increase in BaO concentration. Te-O bond lengths are in the range: 1.97 ± 0.01–1.92 ± 0.01 Å. Ba2+ is mostly in octahedral coordination and the Ba-O bond lengths are in the range: 2.73 ± 0.01 to 2.76 ± 0.03 Å. Te-O co-ordination number is also determined by Raman spectroscopy and it shows good agreement with the neutron data. The short-range structural properties i.e. metal ion coordination number (Nc) and bond lengths (d) were correlated with the stress-optic response. The bonding characteristic, Br values were determined from the structural data of xBaO-(100-x)TeO2 glasses and were used to predict the stress-induced birefringence properties.

  18. Revision to dedicated short range communication roadside equipment specification - RSU 4.1.Bench Test Plan.

    Science.gov (United States)

    2017-04-28

    The document describes the overall process for evaluating Dedicated Short Range Communication (DSRC) Roadside Units (RSU) against USDOT RSU Specification 4.1 in preparation for field evaluation. The Test Cases contained in this document only evaluate...

  19. Amsterdam Short-Term Memory test: a new procedure for the detection of feigned memory deficits

    NARCIS (Netherlands)

    Schagen, S.; Schmand, B.; de Sterke, S.; Lindeboom, J.

    1997-01-01

    The validity of two malingering tests, the newly developed Amsterdam Short-Term Memory (ASTM) test and the Distraction test (Baker, Hanley, Jackson, Kimmance, & Slade, 1993) was examined in a group of patients with closed-head injury (CHI), a normal control group, and a control group with

  20. Within-day variability on short and long walking tests in persons with multiple sclerosis

    NARCIS (Netherlands)

    Feys, P.; Bibby, B.; Romberg, A.; Santoyo, C.; Gebara, B.; de Noordhout, B.M.; Knuts, K.; Bethoux, F.; Skjerbaek, A.; Jensen, E.; Baert, I.; Vaney, C.; de Groot, V.; Dalgas, U.

    2014-01-01

    Objective To compare within-day variability of short (10 m walking test at usual and fastest speed; 10MWT) and long (2 and 6-minute walking test; 2MWT/6MWT) tests in persons with multiple sclerosis. Design Observational study. Setting MS rehabilitation and research centers in Europe and US within

  1. Six-Tube Freezable Radiator Testing and Model Correlation

    Science.gov (United States)

    Lilibridge, Sean T.; Navarro, Moses

    2012-01-01

    Freezable Radiators offer an attractive solution to the issue of thermal control system scalability. As thermal environments change, a freezable radiator will effectively scale the total heat rejection it is capable of as a function of the thermal environment and flow rate through the radiator. Scalable thermal control systems are a critical technology for spacecraft that will endure missions with widely varying thermal requirements. These changing requirements are a result of the spacecraft?s surroundings and because of different thermal loads rejected during different mission phases. However, freezing and thawing (recov ering) a freezable radiator is a process that has historically proven very difficult to predict through modeling, resulting in highly inaccurate predictions of recovery time. These predictions are a critical step in gaining the capability to quickly design and produce optimized freezable radiators for a range of mission requirements. This paper builds upon previous efforts made to correlate a Thermal Desktop(TM) model with empirical testing data from two test articles, with additional model modifications and empirical data from a sub-component radiator for a full scale design. Two working fluids were tested: MultiTherm WB-58 and a 50-50 mixture of DI water and Amsoil ANT.

  2. Short- and long-range correlated motion observed in colloidal glasses and liquids

    International Nuclear Information System (INIS)

    Weeks, Eric R; Crocker, John C; Weitz, D A

    2007-01-01

    We use a confocal microscope to examine the motion of individual particles in a dense colloidal suspension. Close to the glass transition, particle motion is strongly spatially correlated. The correlations decay exponentially with particle separation, yielding a dynamic length scale of O(2-3σ) (in terms of particle diameter σ). This length scale grows modestly as the glass transition is approached. Further, the correlated motion exhibits a strong spatial dependence on the pair correlation function g(r). Motion within glassy samples is weakly correlated, but with a larger spatial scale for this correlation

  3. [Cognition-correlation indices of gender schema: tests of validity].

    Science.gov (United States)

    Ishida, E

    1994-02-01

    Four-hundred and seventy-seven subjects evaluated a set of traits and behaviors in terms of how masculine and feminine they were and in terms of how well they represented their real and ideal self-images. Within-individual correlation coefficients between these evaluations were proposed as measures of psychological gender schemata, because they would represent the degree of matching between the subjects' gender-image and ideal/real self-images of gender-related attributes. The present study aims at examining the construct validity of these measures, by testing them to psychological variables that are known to reflect gender identity. The individual difference variables used as criteria were (a) satisfaction with one's own sex, (b) general happiness, (c) self-esteem (d) gender-conflict, and (e) school and occupational achievement need. Correlations between the gender-schema indices and the criteria variables supported the construct validity of those measures. Advantages of the present measurement over the conventional simple trait approach, such as BSRI, or PAQ are discussed.

  4. Short-ranged radial and tensor correlations in nuclear many-body systems

    International Nuclear Information System (INIS)

    Neff, T.; Feldmeier, H.

    2003-01-01

    The unitary correlation operator method (UCOM) is applied to realistic potentials. The effects of tensor correlations are investigated. The resulting phase shift equivalent correlated interactions are used in the no-core shell model for light nuclei and for mean-field calculations in the Fermionic Molecular Dynamics model for nuclei up to mass A=48. (orig.)

  5. Measuring and testing dependence by correlation of distances

    OpenAIRE

    Székely, Gábor J.; Rizzo, Maria L.; Bakirov, Nail K.

    2007-01-01

    Distance correlation is a new measure of dependence between random vectors. Distance covariance and distance correlation are analogous to product-moment covariance and correlation, but unlike the classical definition of correlation, distance correlation is zero only if the random vectors are independent. The empirical distance dependence measures are based on certain Euclidean distances between sample elements rather than sample moments, yet have a compact representation analogous to the clas...

  6. Testing quantum mechanics using third-order correlations

    International Nuclear Information System (INIS)

    Kinsler, P.

    1996-01-01

    Semiclassical theories similar to stochastic electrodynamics are widely used in optics. The distinguishing feature of such theories is that the quantum uncertainty is represented by random statistical fluctuations. They can successfully predict some quantum-mechanical phenomena; for example, the squeezing of the quantum uncertainty in the parametric oscillator. However, since such theories are not equivalent to quantum mechanics, they will not always be useful. Complex number representations can be used to exactly model the quantum uncertainty, but care has to be taken that approximations do not reduce the description to a hidden variable one. This paper helps show the limitations of open-quote open-quote semiclassical theories,close-quote close-quote and helps show where a true quantum-mechanical treatment needs to be used. Third-order correlations are a test that provides a clear distinction between quantum and hidden variable theories in a way analogous to that provided by the open-quote open-quote all or nothing close-quote close-quote Greenberger-Horne-Zeilinger test of local hidden variable theories. copyright 1996 The American Physical Society

  7. Development of Test-Analysis Models (TAM) for correlation of dynamic test and analysis results

    Science.gov (United States)

    Angelucci, Filippo; Javeed, Mehzad; Mcgowan, Paul

    1992-01-01

    The primary objective of structural analysis of aerospace applications is to obtain a verified finite element model (FEM). The verified FEM can be used for loads analysis, evaluate structural modifications, or design control systems. Verification of the FEM is generally obtained as the result of correlating test and FEM models. A test analysis model (TAM) is very useful in the correlation process. A TAM is essentially a FEM reduced to the size of the test model, which attempts to preserve the dynamic characteristics of the original FEM in the analysis range of interest. Numerous methods for generating TAMs have been developed in the literature. The major emphasis of this paper is a description of the procedures necessary for creation of the TAM and the correlation of the reduced models with the FEM or the test results. Herein, three methods are discussed, namely Guyan, Improved Reduced System (IRS), and Hybrid. Also included are the procedures for performing these analyses using MSC/NASTRAN. Finally, application of the TAM process is demonstrated with an experimental test configuration of a ten bay cantilevered truss structure.

  8. Microstructure and elemental distribution of americium containing MOX fuel under the short term irradiation tests

    International Nuclear Information System (INIS)

    Tanaka, Kosuke; Hirosawa, Takashi; Obayashi, Hiroshi; Koyama, Shin Ichi; Yoshimochi, Hiroshi; Tanaka, Kenya

    2008-01-01

    In order to investigate the effect of americium addition to MOX fuels on the irradiation behavior, the 'Am-1' program is being conducted in JAEA. The Am-1 program consists of two short term irradiation tests of 10-minute and 24 hour irradiations and a steady-state irradiation test. The short-term irradiation tests were successfully completed and the post irradiation examinations (PIEs) are in progress. The PIEs for Am-containing MOX fuels focused on the microstructural evolution and redistribution behavior of Am at the initial stage of irradiation and the results to date are reported

  9. The first DC performance test and analysis of CC conductor short sample at ASIPP conductor test facility

    International Nuclear Information System (INIS)

    Shi Yi; Wu Yu; Liu Huajun; Long Feng; Qian Li; Ren Zhibin; Li Shaolei; Liu Bo; Chen Jinglin

    2012-01-01

    Highlights: ► In this study the first DC performance experiments of ITER correction coil conductor short sample have been carried out in ASIPP test facility. ► A CC conductor short sample was fabricated and tested to confirm the capability of this test facility for qualification tests of CC conductors. ► There is no obvious impact of cycling on DC performance measurement. ► Those measured results of current sharing temperature are in agreement with the expected results from strand scaling - Abstract: The first DC performance experiments of ITER correction coil (CC) conductor short sample have been carried out in the conductor test facility of Institute of Plasma Physics, CAS (ASIPP) in January this year. Those experiments aim to investigate the DC performance of ITER CC conductor. The tested conductor short sample is bended as a half circle with the diameter of 270 mm to meet the background magnetic field shape. The half circle part of sample is longer than the final twist pitch. The current sharing temperature (T cs ) in the 3.86 T external magnetic field (B ex ), ≤12 kA could be measured including the critical current (I c ) run. There is no obvious impact of 1000 cycles on DC performance. Those measured T cs results are in agreement with the expected results from strand scaling.

  10. On the sensitivity of nucleon-nucleon correlations to the form of short-range potential

    International Nuclear Information System (INIS)

    Gmitro, M.; Kvasil, J.; Lednicky, R.; Lyuboshitz, V.L.

    1986-01-01

    Nucleon-nucleon correlation characteristics are calculated for several phenomenological and realistic strong potentials. The results show that a square-well potential reasonably well approximates the nucleon-nucleon interaction if one calculates the correlations between nucleons generated in a region with an r.m.s. radius larger than 1.5-2 fm. Vice versa, the correlations of nucleons emitted from a smaller generation region are sensitive to the form of the assumed nucleon-nucleon potential. (author)

  11. Are Soft Short Tests Good Indicators of Internal Li-ion Cell Defects?

    Science.gov (United States)

    Jeevarajan, J.; Chung, J.-S.; Jung, K.; Park, J.

    2013-01-01

    The self discharge test at full state of charge, may not be a good one to detect subtle defects since the li-ion chemistry has the highest self discharge at full state of charge. One should characterize self discharge versus storage time for each cell manufacturer/design to differentiate between normal self discharge and that due to a subtle manufacturing defect. The various soft short test methods indicate that if this test is carried out at full discharge (0% SOC) with all capacity removed (by lowering the current load in a stepwise manner to the same end of discharge voltage), then the cells need to be placed in storage for more than 72 hours to get a good analysis on the presence of subtle defects since it takes more than 72 hours to achieve voltage stabilization. If the cells are to be charged up even to a small percentage (ex. 1%), 72 hours are sufficient to determine issues. However, the pass/fail criteria should be based on a valid OCV decline. Less than 10 mV voltage decline is not a good method to detect subtle defects. As mentioned in the first bullet, self discharge is a competing reaction when a charge is introduced and hence a characterization of the self discharge versus storage time is required to fully correlate voltage decline to a failure due to a subtle defect. Soft short test method cannot be relied on for defect detection because cells with and without voltage decline seemed to have similar defects and characteristics. Screening methods such as internal resistance and capacity as well as a 3-sigma range for OCV, mass and dimensions should be used to screen out outliers. A very critical aspect in the understanding of subtle defects is to carry out destructive analysis of cells from every lot to confirm the quality of production and screen all cells and batteries in a stringent manner to have a high quality set of flight cells. Self Discharge Test: Fully charged cells shall be placed in Open circuit stand for 72 hours (OCV measurement twice a

  12. Using Response Surface Methods to Correlate the Modal Test of an Inflatable Test Article

    Science.gov (United States)

    Gupta, Anju

    2013-01-01

    This paper presents a practical application of response surface methods (RSM) to correlate a finite element model of a structural modal test. The test article is a quasi-cylindrical inflatable structure which primarily consists of a fabric weave, with an internal bladder and metallic bulkheads on either end. To mitigate model size, the fabric weave was simplified by representing it with shell elements. The task at hand is to represent the material behavior of the weave. The success of the model correlation is measured by comparing the four major modal frequencies of the analysis model to the four major modal frequencies of the test article. Given that only individual strap material properties were provided and material properties of the overall weave were not available, defining the material properties of the finite element model became very complex. First it was necessary to determine which material properties (modulus of elasticity in the hoop and longitudinal directions, shear modulus, Poisson's ratio, etc.) affected the modal frequencies. Then a Latin Hypercube of the parameter space was created to form an efficiently distributed finite case set. Each case was then analyzed with the results input into RSM. In the resulting response surface it was possible to see how each material parameter affected the modal frequencies of the analysis model. If the modal frequencies of the analysis model and its corresponding parameters match the test with acceptable accuracy, it can be said that the model correlation is successful.

  13. Short-Range Correlated Magnetic Core-Shell CrO₂/Cr₂O₃ Nanorods: Experimental Observations and Theoretical Considerations.

    Science.gov (United States)

    Gandhi, Ashish C; Li, Tai-Yue; Chan, Ting Shan; Wu, Sheng Yun

    2018-05-09

    With the evolution of synthesis and the critical characterization of core-shell nanostructures, short-range magnetic correlation is of prime interest in employing their properties to develop novel devices and widespread applications. In this regard, a novel approach of the magnetic core-shell saturated magnetization (CSSM) cylinder model solely based on the contribution of saturated magnetization in one-dimensional CrO₂/Cr₂O₃ core-shell nanorods (NRs) has been developed and applied for the determination of core-diameter and shell-thickness. The nanosized effect leads to a short-range magnetic correlation of ferromagnetic core-CrO₂ extracted from CSSM, which can be explained using finite size scaling method. The outcome of this study is important in terms of utilizing magnetic properties for the critical characterization of core-shell nanomagnetic materials.

  14. Properties of short-range and long-range correlation energy density functionals from electron-electron coalescence

    International Nuclear Information System (INIS)

    Gori-Giorgi, Paola; Savin, Andreas

    2006-01-01

    The combination of density-functional theory with other approaches to the many-electron problem through the separation of the electron-electron interaction into a short-range and a long-range contribution is a promising method, which is raising more and more interest in recent years. In this work some properties of the corresponding correlation energy functionals are derived by studying the electron-electron coalescence condition for a modified (long-range-only) interaction. A general relation for the on-top (zero electron-electron distance) pair density is derived, and its usefulness is discussed with some examples. For the special case of the uniform electron gas, a simple parametrization of the on-top pair density for a long-range only interaction is presented and supported by calculations within the ''extended Overhauser model.'' The results of this work can be used to build self-interaction corrected short-range correlation energy functionals

  15. Long-term plasticity determines the postsynaptic response to correlated afferents with multivesicular short-term synaptic depression

    Directory of Open Access Journals (Sweden)

    Alexander David Bird

    2014-01-01

    Full Text Available Synchrony in a presynaptic population leads to correlations in vesicle occupancy at the active sites for neurotransmitter release. The number of independent release sites per presynaptic neuron, a synaptic parameter recently shown to be modifed during long-term plasticity, will modulate these correlations and therefore have a significant effect on the firing rate of the postsynaptic neuron. To understand how correlations from synaptic dynamics and from presynaptic synchrony shape the postsynaptic response, we study a model of multiple release site short-term plasticity and derive exact results for the crosscorrelation function of vesicle occupancy and neurotransmitter release, as well as the postsynaptic voltage variance. Using approximate forms for the postsynaptic firing rate in the limits of low and high correlations, we demonstrate that short-term depression leads to a maximum response for an intermediate number of presynaptic release sites, and that this leads to a tuning-curve response peaked at an optimal presynaptic synchrony setby the number of neurotransmitter release sites per presynaptic neuron. These effects arise because, above a certain level of correlation, activity in the presynaptic population is overly strong resulting in wastage of the pool of releasable neurotransmitter. As the nervous system operates under constraints of efficient metabolism it is likely that this phenomenon provides an activity-dependent constraint on network architecture.

  16. On the interplay between short and long term memory in the power-law cross-correlations setting

    Czech Academy of Sciences Publication Activity Database

    Krištoufek, Ladislav

    2015-01-01

    Roč. 421, č. 1 (2015), s. 218-222 ISSN 0378-4371 R&D Projects: GA ČR(CZ) GP14-11402P Institutional support: RVO:67985556 Keywords : Power-law cross-correlations * Long term memory * Short term memory Subject RIV: AH - Economics Impact factor: 1.785, year: 2015 http://library.utia.cas.cz/separaty/2015/E/kristoufek-0452316.pdf

  17. An investigation of the genetic toxicology of irradiated foodstuffs using short-term test systems

    International Nuclear Information System (INIS)

    Phillips, B.J.; Kranz, E.; Elias, P.S.

    1980-01-01

    As part of a programme of short-term tests used to detect possible genetic toxicity in irradiated foodstuffs, cultured Chinese hamster ovary cells were exposed to extracts and digests of irradiated and unirradiated dates, fish and chicken and subjected to tests for cytotoxicity, sister chromatid exchange induction and mutation to thioguanine resistance. The results showed no evidence of genetic toxicity induced in food by irradiation. The general applicability of cell culture tests to the detection of mutagens in food is discussed. (author)

  18. Phonological and Sensory Short-Term Memory Are Correlates and Both Affected in Developmental Dyslexia

    Science.gov (United States)

    Laasonen, Marja; Virsu, Veijo; Oinonen, Suvi; Sandbacka, Mirja; Salakari, Anita; Service, Elisabet

    2012-01-01

    We investigated whether poor short-term memory (STM) in developmental dyslexia affects the processing of sensory stimulus sequences in addition to phonological material. STM for brief binary non-verbal stimuli (light flashes, tone bursts, finger touches, and their crossmodal combinations) was studied in 20 Finnish adults with dyslexia and 24…

  19. Short-term duloxetine administration affects neural correlates of mood-congruent memory

    NARCIS (Netherlands)

    Tendolkar, Indira; van Wingen, Guido; Urner, Maren; Verkes, Robbert Jan; Fernández, Guillén

    2011-01-01

    It is unknown how antidepressants reverse mood-congruent memory bias, a cognitive core factor causing and maintaining depression. Using a double-blind, placebo-controlled, cross-over design, we investigated the effect of a short-term treatment (14 days) with the dual reuptake inhibitor duloxetine on

  20. Concurrent Validity and Feasibility of Short Tests Currently Used to Measure Early Childhood Development in Large Scale Studies.

    Directory of Open Access Journals (Sweden)

    Marta Rubio-Codina

    Full Text Available In low- and middle-income countries (LIMCs, measuring early childhood development (ECD with standard tests in large scale surveys and evaluations of interventions is difficult and expensive. Multi-dimensional screeners and single-domain tests ('short tests' are frequently used as alternatives. However, their validity in these circumstances is unknown. We examined the feasibility, reliability, and concurrent validity of three multi-dimensional screeners (Ages and Stages Questionnaires (ASQ-3, Denver Developmental Screening Test (Denver-II, Battelle Developmental Inventory screener (BDI-2 and two single-domain tests (MacArthur-Bates Short-Forms (SFI and SFII, WHO Motor Milestones (WHO-Motor in 1,311 children 6-42 months in Bogota, Colombia. The scores were compared with those on the Bayley Scales of Infant and Toddler Development (Bayley-III, taken as the 'gold standard'. The Bayley-III was given at a center by psychologists; whereas the short tests were administered in the home by interviewers, as in a survey setting. Findings indicated good internal validity of all short tests except the ASQ-3. The BDI-2 took long to administer and was expensive, while the single-domain tests were quickest and cheapest and the Denver-II and ASQ-3 were intermediate. Concurrent validity of the multi-dimensional tests' cognitive, language, and fine motor scales with the corresponding Bayley-III scale was low below 19 months. However, it increased with age, becoming moderate-to-high over 30 months. In contrast, gross motor scales' concurrence was high under 19 months and then decreased. Of the single-domain tests, the WHO-Motor had high validity with gross motor under 16 months, and the SFI and SFII expressive scales showed moderate correlations with language under 30 months. Overall, the Denver-II was the most feasible and valid multi-dimensional test and the ASQ-3 performed poorly under 31 months. By domain, gross motor development had the highest concurrence

  1. Correlation of volumetric and fractal measurements of brain atrophy with neuropsychological tests in patients with dementive disorders

    International Nuclear Information System (INIS)

    Czarnecka, A.; Sasiadek, M.; Filarski, J.

    2008-01-01

    Brain atrophy is one of the features of the dementive diseases, but also of other neurodegenerative disorders as well as physiological brain aging. The aim of the study was to define the relationship between the brain atrophy measurements and the degree of the severity of dementive process based on the neuropsychological tests (MMSE and Clock Drawing Test). In 68 patients with diagnosed impairment of cognitive functions due to dementia, neuropsychological tests (MMSE and Clock Drawing Test) and CT studies were performed. On the basis of CT images we evaluated cortical and subcortical atrophy with 3 methods; visual, semiautomatic (volumetric) and automatic method based on fractal geometry calculations; the latter was characterized by very short time of measurements. The correlation between neuropsychological tests and brain atrophy measurements has been assessed using Pearson's correlation test. No statistical correlation was found between the results of neuropsychological tests and measurements of the brain atrophy (both cortical and subcortical) using all three methods mentioned above. Single measurement of the generalized cortical and subcortical atrophy is not correlated with the results of neuropsychological tests. In our opinion, these measurements might be valuable in follow-up of the dementive process to compare progression of the atrophic changes with the changes of the neuropsychological tests results, especially using very quick automatic method, supplemented by local atrophy measurements. (authors)

  2. Neuronal correlate of pictorial short-term memory in the primate temporal cortexYasushi Miyashita

    Science.gov (United States)

    Miyashita, Yasushi; Chang, Han Soo

    1988-01-01

    It has been proposed that visual-memory traces are located in the temporal lobes of the cerebral cortex, as electric stimulation of this area in humans results in recall of imagery1. Lesions in this area also affect recognition of an object after a delay in both humans2,3 and monkeys4-7 indicating a role in short-term memory of images8. Single-unit recordings from the temporal cortex have shown that some neurons continue to fire when one of two or four colours are to be remembered temporarily9. But neuronal responses selective to specific complex objects10-18 , including hands10,13 and faces13,16,17, cease soon after the offset of stimulus presentation10-18. These results led to the question of whether any of these neurons could serve the memory of complex objects. We report here a group of shape-selective neurons in an anterior ventral part of the temporal cortex of monkeys that exhibited sustained activity during the delay period of a visual short-term memory task. The activity was highly selective for the pictorial information to be memorized and was independent of the physical attributes such as size, orientation, colour or position of the object. These observations show that the delay activity represents the short-term memory of the categorized percept of a picture.

  3. Correlates of HIV testing refusal among emergency department patients in the opt-out testing era.

    Science.gov (United States)

    Setse, Rosanna W; Maxwell, Celia J

    2014-05-01

    Opt-out HIV screening is recommended by the CDC for patients in all healthcare settings. We examined correlates of HIV testing refusal among urban emergency department (ED) patients. Confidential free HIV screening was offered to 32,633 ED patients in an urban tertiary care facility in Washington, DC, during May 2007-December 2011. Demographic differences in testing refusals were examined using χ(2) tests and generalized linear models. HIV testing refusal rates were 47.7 % 95 % CI (46.7-48.7), 11.7 % (11.0-12.4), 10.7 % (10.0-11.4), 16.9 % (15.9-17.9) and 26.9 % (25.6-28.2) in 2007, 2008, 2009, 2010 and 2011 respectively. Persons 33-54 years of age [adjusted prevalence ratio (APR) 1.42, (1.36-1.48)] and those ≥ 55 years [APR 1.39 (1.31-1.47)], versus 33-54 years; and females versus males [APR 1.07 (1.02-1.11)] were more likely to refuse testing. Opt-out HIV testing is feasible and sustainable in urban ED settings. Efforts are needed to encourage testing among older patients and women.

  4. Waveform correlation and coherence of short-period seismic noise within Gauribidanur array with implications for event detection

    International Nuclear Information System (INIS)

    Bhadauria, Y.S.; Arora, S.K.

    1995-01-01

    In continuation with our effort to model the short-period micro seismic noise at the seismic array at Gauribidanur (GBA), we have examined in detail time-correlation and spectral coherence of the noise field within the array space. This has implications of maximum possible improvement in signal-to-noise ratio (SNR) relevant to event detection. The basis of this study is about a hundred representative wide-band noise samples collected from GBA throughout the year 1992. Both time-structured correlation as well as coherence of the noise waveforms are found to be practically independent of the inter element distances within the array, and they exhibit strong temporal and spectral stability. It turns out that the noise is largely incoherent at frequencies ranging upwards from 2 Hz; the coherency coefficient tends to increase in the lower frequency range attaining a maximum of 0.6 close to 0.5 Hz. While the maximum absolute cross-correlation also diminishes with increasing frequency, the zero-lag cross-correlation is found to be insensitive to frequency filtering regardless of the pass band. An extremely small value of -0.01 of the zero-lag correlation and a comparatively higher year-round average estimate at 0.15 of the maximum absolute time-lagged correlation yields an SNR improvement varying between a probable high of 4.1 and a low of 2.3 for the full 20-element array. 19 refs., 6 figs

  5. Correlates of individual, and age-related, differences in short-term learning.

    Science.gov (United States)

    Zhang, Zhiyong; Davis, Hasker P; Salthouse, Timothy A; Tucker-Drob, Elliot M

    2007-07-01

    Latent growth models were applied to data on multitrial verbal and spatial learning tasks from two independent studies. Although significant individual differences in both initial level of performance and subsequent learning were found in both tasks, age differences were found only in mean initial level, and not in mean learning. In neither task was fluid or crystallized intelligence associated with learning. Although there were moderate correlations among the level parameters across the verbal and spatial tasks, the learning parameters were not significantly correlated with one another across task modalities. These results are inconsistent with the existence of a general (e.g., material-independent) learning ability.

  6. Physiological Correlations with Short, Medium, and Long Cycling Time-Trial Performance

    Science.gov (United States)

    Borszcz, Fernando K.; Tramontin, Artur F.; de Souza, Kristopher M.; Carminatti, Lorival J.; Costa, Vitor P.

    2018-01-01

    Purpose: Several studies have demonstrated that physiological variables predict cycling endurance performance. However, it is still unclear whether the predictors will change over different performance durations. The aim of this study was to assess the correlations between physiological variables and cycling time trials with different durations.…

  7. Device for testing continuity and/or short circuits in a cable

    Science.gov (United States)

    Hayhurst, Arthur R. (Inventor)

    1995-01-01

    A device for testing current paths is attachable to a conductor. The device automatically checks the current paths of the conductor for continuity of a center conductor, continuity of a shield and a short circuit between the shield and the center conductor. The device includes a pair of connectors and a circuit to provide for testing of the conductive paths of the cable. The pair of connectors electrically connects the conductive paths of a cable to be tested with the circuit paths of the circuit. The circuit paths in the circuit include indicators to simultaneously indicate the results of the testing.

  8. Reliability of the Test of Wheeled Mobility (TOWM) and the Short Wheelie Test

    NARCIS (Netherlands)

    Fliess-Douer, Osnat; Van der Woude, Lucas H. V.; Vanlandewijck, Yves C.

    Objective: To assess the reliability of the Test of Wheeled Mobility (TOWM) and the Wheelie test. Design: Cohort study. Setting: Gymnasium. Participants: Manual wheelchair users (N=30, age 23-53y) with a spinal cord injury. Intervention: Participants performed the 30 skills of the TOWM and the 8

  9. A test of multiple correlation temporal window characteristic of non-Markov processes

    Science.gov (United States)

    Arecchi, F. T.; Farini, A.; Megna, N.

    2016-03-01

    We introduce a sensitive test of memory effects in successive events. The test consists of a combination K of binary correlations at successive times. K decays monotonically from K = 1 for uncorrelated events as a Markov process. For a monotonic memory fading, K1 temporal window in cognitive tasks consisting of the visual identification of the front face of the Necker cube after a previous presentation of the same. We speculate that memory effects provide a temporal window with K>1 and this experiment could be a possible first step towards a better comprehension of this phenomenon. The K>1 behaviour is maximal at an inter-measurement time τ around 2s with inter-subject differences. The K>1 persists over a time window of 1s around τ; outside this window the K1 window in pairs of successive perceptions suggests that, at variance with single visual stimuli eliciting a suitable response, a pair of stimuli shortly separated in time displays mutual correlations.

  10. Functional neuroimaging and behavioral correlates of capacity decline in visual short-term memory after sleep deprivation.

    Science.gov (United States)

    Chee, Michael W L; Chuah, Y M Lisa

    2007-05-29

    Sleep deprivation (SD) impairs short-term memory, but it is unclear whether this is because of reduced storage capacity or processes contributing to appropriate information encoding. We evaluated 30 individuals twice, once after a night of normal sleep and again after 24 h of SD. In each session, we evaluated visual memory capacity by presenting arrays of one to eight colored squares. Additionally, we measured cortical responses to varying visual array sizes without engaging memory. The magnitude of intraparietal sulcus activation and memory capacity after normal sleep were highly correlated. SD elicited a pattern of activation in both tasks, indicating that deficits in visual processing and visual attention accompany and could account for loss of short-term memory capacity. Additionally, a comparison between better and poorer performers showed that preservation of precuneus and temporoparietal junction deactivation with increasing memory load corresponds to less performance decline when one is sleep-deprived.

  11. Correlation of optical energy gap with the nearest neighbour short range order in amorphous V2O5 films

    International Nuclear Information System (INIS)

    Dhawan, Sahil; Vedeshwar, Agnikumar G; Tandon, R P

    2011-01-01

    The optical and structural properties of well characterized vacuum-evaporated amorphous V 2 O 5 films were studied in the thickness range 5-500 nm. The structural analyses show that V-O, O-O and V-V nearest neighbour distances defining the short range order vary nonlinearly with film thickness. The optical absorption shows thickness-dependent energy gap (E g ) and the nonlinear behaviour of thickness-dependent E g is similar to that of nearest neighbour distance with film thickness. The E g correlates linearly very well with all the three nearest neighbour distances. The variation of E g with film thickness is attributed to the residual stress in the film which causes the changes in short range order. The change in E g corresponding to the change in V-O distance was found to be 35 eV nm -1 . This change is almost three times of that with V-V distance.

  12. Correlates of individual, and age-related, differences in short-term learning☆

    OpenAIRE

    Zhang, Zhiyong; Davis, Hasker P.; Salthouse, Timothy A.; Tucker-Drob, Elliot M.

    2007-01-01

    Latent growth models were applied to data on multitrial verbal and spatial learning tasks from two independent studies. Although significant individual differences in both initial level of performance and subsequent learning were found in both tasks, age differences were found only in mean initial level, and not in mean learning. In neither task was fluid or crystallized intelligence associated with learning. Although there were moderate correlations among the level parameters across the verb...

  13. Short-term step-to-step correlation in plantar pressure distributions during treadmill walking, and implications for footprint trail analysis.

    Science.gov (United States)

    Pataky, Todd C; Savage, Russell; Bates, Karl T; Sellers, William I; Crompton, Robin H

    2013-09-01

    The gait cycle is continuous, but for practical reasons one is often forced to analyze one or only a few adjacent cycles, for example in non-treadmill laboratory investigations and in fossilized footprint analysis. The nature of variability in long-term gait cycle dynamics has been well-investigated, but short-term variability, and specifically correlation, which are highly relevant to short gait bouts, have not. We presently tested for step-to-step autocorrelation in a total of 5243 plantar pressure (PP) distributions from ten subjects who walked at 1.1m/s on an instrumented treadmill. Following spatial foot alignment, data were analyzed both from three points of interest (POI): heel, central metatarsals, and hallux, and for the foot surface as a whole, in a mass-univariate manner. POI results revealed low average step-to-step autocorrelation coefficients (r=0.327±0.094; mean±st. dev.). Formal statistical testing of the whole-foot r distributions reached significance over an average of only 0.42±0.52% of the foot's surface, even for a highly conservative uncorrected threshold of p<0.05. The common assumption, that short gait bouts consist of independent cycles, is therefore not refuted by the present PP results. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Neural correlates of auditory short-term memory in rostral superior temporal cortex.

    Science.gov (United States)

    Scott, Brian H; Mishkin, Mortimer; Yin, Pingbo

    2014-12-01

    Auditory short-term memory (STM) in the monkey is less robust than visual STM and may depend on a retained sensory trace, which is likely to reside in the higher-order cortical areas of the auditory ventral stream. We recorded from the rostral superior temporal cortex as monkeys performed serial auditory delayed match-to-sample (DMS). A subset of neurons exhibited modulations of their firing rate during the delay between sounds, during the sensory response, or during both. This distributed subpopulation carried a predominantly sensory signal modulated by the mnemonic context of the stimulus. Excitatory and suppressive effects on match responses were dissociable in their timing and in their resistance to sounds intervening between the sample and match. Like the monkeys' behavioral performance, these neuronal effects differ from those reported in the same species during visual DMS, suggesting different neural mechanisms for retaining dynamic sounds and static images in STM. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Testing for time-based correlates of perceived gender discrimination.

    Science.gov (United States)

    Blau, Gary; Tatum, Donna Surges; Ward-Cook, Kory; Dobria, Lidia; McCoy, Keith

    2005-01-01

    Using a sample of 201 medical technologists (MTs) over a five-year period, this study extends initial findings on perceived gender discrimination (PGD) by Blau and Tatum (2000) by applying organizational justice variables and internal-external locus of control as hypothesized correlates of PGD. Three types of organizational justice were measured: distributive, procedural, and interactional. General relationships found include locus of control being related to PGD such that internals perceived lower PGD. Also, distributive, procedural, and interactional justice were negatively related to PGD. However, increasing the time interval between these correlates weakened their relationships. The relationship of interactional justice to PGD remained the most "resistant" to attenuation over time.

  16. Searching for Short Range Correlations Using (e,e'NN) Reactions

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Bin [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2003-02-01

    Electron induced two nucleon knockout reactions (e,e'pp) and (e,e'np) were performed for 3He, 4He, and 12C nuclei with incident energies of 2.261 GeV and 4.461 GeV using the CLAS detector at Jefferson Lab. Events with missing momenta lower than the Fermi level and missing energies smaller than the pion threshold were studied. The residual system was assumed to be a spectator and the process was considered as a quasi-free knockout of an NN pair. The data showed that the initial momentum extends up to 800 MeV/c with considerable strength. The cross sections for 3He(e,e'pp)n were compared to the calculations of J.M. Laget. It was found that the final state interactions (FSI) and the meson exchange currents (MEC) dominate the cross sections and the short range properties of the NN pair were substantially undermined. However, the node of the S state wave function of the pp pair at around 400 MeV/c initial momentum starts to be recognizable in the 4.461 GeV data. The data and the theory suggest that with higher momentum transfers, especially in the region xBj > 1, the competing processes such as FSI and MEC will be less important and the detailed study of the short-range properties of nucleons inside nuclei will be more desirable.

  17. Correlations between power and test reactor data bases

    International Nuclear Information System (INIS)

    Guthrie, G.L.; Simonen, E.P.

    1989-02-01

    Differences between power reactor and test reactor data bases have been evaluated. Charpy shift data has been assembled from specimens irradiated in both high-flux test reactors and low-flux power reactors. Preliminary tests for the existence of a bias between test and power reactor data bases indicate a possible bias between the weld data bases. The bias is nonconservative for power predictive purposes, using test reactor data. The lesser shift for test reactor data compared to power reactor data is interpreted primarily in terms of greater point defect recombination for test reactor fluxes compared to power reactor fluxes. The possibility of greater thermal aging effects during lower damage rates is also discussed. 15 refs., 5 figs., 2 tabs

  18. Mean-Field Theory of Electrical Double Layer In Ionic Liquids with Account of Short-Range Correlations

    International Nuclear Information System (INIS)

    Goodwin, Zachary A.H.; Feng, Guang; Kornyshev, Alexei A.

    2017-01-01

    We develop the theory of the electrical double layer in ionic liquids as proposed earlier by Kornyshev (2007). In the free energy function we keep the so called ‘short-range correlation terms’ which were omitted there. With some simplifying assumptions, we arrive at a modified expression for differential capacitance, which makes differential capacitance curves less sharply depending on electrode potential and having smaller values at extrema than in the previous theory. This brings the results closer to typical experimental observations, and makes it appealing to use this formalism for treatment of experimental data. Implications on Debye length and the extent of ion paring in ionic liquids are then briefly discussed.

  19. Development of a radionuclide short-test for the evaluation of engine oils in respect to cam- and cylinder linear wear by using OM 616 Kombi-Test conditions

    International Nuclear Information System (INIS)

    Volz, J.; Lausch, W.

    1980-05-01

    A survey is given on the studies performed since 1973 on the development of radionuclide short-test procedure, based on the test procedure of the OM 616 Kombi-Test, for the evaluation of engine oils in respect to cam- and cylinder liner wear (deuteron activated Co-56). Out of the results of these studies on experimental short test procedure has been elaborated to evaluate cylinder liner wear. With this experimental procedure some round robin testing has been carried out by three laboratories using a well-known reference oil and two test oils. The results of this round robin test led to further improvements in the test procedure. This improved test procedure has become a suitable screening-test for the development of engine oils in respect to cylinder liner wear. It never can replace the OM 616-Kombi-Test as a whole, but it will complete it. The radionuclide short test gets results quicker and at lower costs than the Kombi-Test, discriminates between hot test and cold-warm test results, and gives results even with correlation to the Kombi-Test by comparison to an approved reference oil. For such screening work, the repeatability of the test is also sufficient. (orig./HP) [de

  20. Neural correlates of testing effects in vocabulary learning.

    Science.gov (United States)

    van den Broek, Gesa S E; Takashima, Atsuko; Segers, Eliane; Fernández, Guillén; Verhoeven, Ludo

    2013-09-01

    Tests that require memory retrieval strongly improve long-term retention in comparison to continued studying. For example, once learners know the translation of a word, restudy practice, during which they see the word and its translation again, is less effective than testing practice, during which they see only the word and retrieve the translation from memory. In the present functional magnetic resonance imaging (fMRI) study, we investigated the neuro-cognitive mechanisms underlying this striking testing effect. Twenty-six young adults without prior knowledge of Swahili learned the translation of 100 Swahili words and then further practiced the words in an fMRI scanner by restudying or by testing. Recall of the translations on a final memory test after one week was significantly better and faster for tested words than for restudied words. Brain regions that were more active during testing than during restudying included the left inferior frontal gyrus, ventral striatum, and midbrain areas. Increased activity in the left inferior parietal and left middle temporal areas during testing but not during restudying predicted better recall on the final memory test. Together, results suggest that testing may be more beneficial than restudying due to processes related to targeted semantic elaboration and selective strengthening of associations between retrieval cues and relevant responses, and may involve increased effortful cognitive control and modulations of memory through striatal motivation and reward circuits. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Manifestation of short-range correlations in deep inelastic scattering in deuterons and nuclei

    International Nuclear Information System (INIS)

    Strikman, M.I.; Frankfurt, L.L.

    1981-01-01

    It is shown that deep inelastic processes of the type l+A→l'+X and l+A→l'+p+X are an effective tool to study phenomena associated with the nucleon-nucleon interaction core, in particular the problem of cumulative particles. We have calculated the effects of scaling violation in the e+D→e+X process in accordance with the data of Schutz et al. It is shown that recent data on the reaction ν (nu-bar)+A→μ+p+X agree with the predictions of the few-nucleon correlation model

  2. A short-term longitudinal study of correlates and sequelae of attachment security in autism

    Science.gov (United States)

    Rozga, Agata; Hesse, Erik; Main, Mary; Duschinsky, Robbie; Beckwith, Leila; Sigman, Marian

    2018-01-01

    ABSTRACT In this short-term longitudinal study, 30 preschool-aged children with autism were first observed in Ainsworth’s Strange Situation Procedure and, separately, interacting with the primary caregiver in the home. One year later, each child completed both a developmental assessment and an observational assessment of empathic responding. Behaviors typical for children with autism were distinguished from behaviors suggestive of relationally based attachment disorganization. Forty-five percent of the children were classified as securely attached. The secure group demonstrated language skills superior to those of the insecurely attached group, concurrently and during the follow-up. Compared to parents of children who were insecurely attached, parents of securely attached children were rated as more sensitive. Compared to both organized insecure and disorganized children, secure children were rated as more responsive to an examiner’s apparent distress during the follow-up relative to their ratings at intake, whereas empathy ratings of children with insecure classifications did not increase. Importantly, attachment security was associated with empathy above and beyond the contribution of children’s language level. These results indicate that the sequelae of attachment security in autism may be similar to those documented for typically developing children. PMID:28959921

  3. Thermocouple correlation transit time flowmeter tests at WCL

    International Nuclear Information System (INIS)

    Lassahn, G.D.

    1976-11-01

    Scoping tests indicate the feasibility for using transit time flowmeters with thermocouple sensors in steam-water steady state flow. Conclusive results were not obtained. More conclusive results are expected from tests to be conducted in the semiscale facility with a redesigned transit time thermocouple sensor

  4. Neural correlates of testing effects in vocabulary learning

    NARCIS (Netherlands)

    Broek, G.S.E. van den; Takashima, A.; Segers, P.C.J.; Fernandez, G.S.E.; Verhoeven, L.T.W.

    2013-01-01

    Tests that require memory retrieval strongly improve long-term retention in comparison to continued studying. For example, once learners know the translation of a word, restudy practice, during which they see the word and its translation again, is less effective than testing practice, during which

  5. Hybridization interactions between probesets in short oligo microarrays lead to spurious correlations

    Directory of Open Access Journals (Sweden)

    Miller Crispin J

    2006-06-01

    Full Text Available Abstract Background Microarrays measure the binding of nucleotide sequences to a set of sequence specific probes. This information is combined with annotation specifying the relationship between probes and targets and used to make inferences about transcript- and, ultimately, gene expression. In some situations, a probe is capable of hybridizing to more than one transcript, in others, multiple probes can target a single sequence. These 'multiply targeted' probes can result in non-independence between measured expression levels. Results An analysis of these relationships for Affymetrix arrays considered both the extent and influence of exact matches between probe and transcript sequences. For the popular HGU133A array, approximately half of the probesets were found to interact in this way. Both real and simulated expression datasets were used to examine how these effects influenced the expression signal. It was found not only to lead to increased signal strength for the affected probesets, but the major effect is to significantly increase their correlation, even in situations when only a single probe from a probeset was involved. By building a network of probe-probeset-transcript relationships, it is possible to identify families of interacting probesets. More than 10% of the families contain members annotated to different genes or even different Unigene clusters. Within a family, a mixture of genuine biological and artefactual correlations can occur. Conclusion Multiple targeting is not only prevalent, but also significant. The ability of probesets to hybridize to more than one gene product can lead to false positives when analysing gene expression. Comprehensive annotation describing multiple targeting is required when interpreting array data.

  6. Discrete capacity limits and neuroanatomical correlates of visual short-term memory for objects and spatial locations.

    Science.gov (United States)

    Konstantinou, Nikos; Constantinidou, Fofi; Kanai, Ryota

    2017-02-01

    Working memory is responsible for keeping information in mind when it is no longer in view, linking perception with higher cognitive functions. Despite such crucial role, short-term maintenance of visual information is severely limited. Research suggests that capacity limits in visual short-term memory (VSTM) are correlated with sustained activity in distinct brain areas. Here, we investigated whether variability in the structure of the brain is reflected in individual differences of behavioral capacity estimates for spatial and object VSTM. Behavioral capacity estimates were calculated separately for spatial and object information using a novel adaptive staircase procedure and were found to be unrelated, supporting domain-specific VSTM capacity limits. Voxel-based morphometry (VBM) analyses revealed dissociable neuroanatomical correlates of spatial versus object VSTM. Interindividual variability in spatial VSTM was reflected in the gray matter density of the inferior parietal lobule. In contrast, object VSTM was reflected in the gray matter density of the left insula. These dissociable findings highlight the importance of considering domain-specific estimates of VSTM capacity and point to the crucial brain regions that limit VSTM capacity for different types of visual information. Hum Brain Mapp 38:767-778, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  7. Correlation of geotextile puncture test methods : research brief.

    Science.gov (United States)

    2017-05-01

    Geotextiles are commonly used in pavements, earth retaining structures, landfills and other geotechnical contexts. Various tests are conducted to evaluate and classify geotextiles to determine their suitability for each of these applications. The AST...

  8. X-ray testing for short-time dynamic applications; Roentgenuntersuchungen fuer kurzzeitdynamische Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Kurfiss, Malte; Moser, Stefan; Popko, Gregor; Nau, Siegfried [Fraunhofer-Institut fuer Kurzzeitdynamik, Efringen-Kirchen (Germany). Ernst-Mach-Inst. (EMI)

    2017-08-01

    For nondestructive testing purposes new challenges are short-time dynamic processes. The application of x-ray flash tubes and modern high-speed cameras allows the observation of the opening of air-bags or the energy absorption of compressed tubes as occurring during a vehicle crash. Special algorithms designed for computerized tomography analyses allow the 3D reconstruction at individual time points of the dynamic process. Possibilities and limitations of the actual techniques are discussed.

  9. Mercury Induced Biochemical Alterations As Oxidative Stress In Mugil Cephalus In Short Term Toxicity Test

    OpenAIRE

    J.S.I Rajkumar; Samuel Tennyson

    2013-01-01

    Mugil cephalus juveniles of size 2.5 ±0.6cm were exposed to mercury in short term chronic toxicity test through static renewal bioassay to detect the possible biochemical agent as biomarkers in aquatic pollution and in estuarine contamination as specific. Lipid peroxidation levels, glutathione S -transferase, catalase, reduced glutathione and acetylcholinesterase were studied as biochemical parameters. Increased thio-barbituric acid reactive substances levels were observed under exposur...

  10. Fundamental tests and measures of the structure of matter at short distances

    International Nuclear Information System (INIS)

    Brodsky, S.J.

    1981-07-01

    Recent progress in gauge field theories has led to a new perspective on the structure of matter and basic interactions at short distances. It is clear that at very high energies quantum electrodynamics, together with the weak and strong interactions, are part of a unified theory with new fundamental constants, new symmetries, and new conservation laws. A non-technical introduction to these topics is given, with emphasis on fundamental tests and measurements. 21 references

  11. Reliability testing of the Danish version of the Kidney Disease Quality of Life Short Form

    DEFF Research Database (Denmark)

    Molsted, Stig; Heaf, James; Prescott, Lotte

    2005-01-01

    . MATERIAL AND METHODS: Translation into Danish and back-translation into English were performed. Pilot, field and internal consistency reliability tests were performed. RESULTS: Cronbach's alpha coefficients for the internal reliability test ranged from 0.77 to 0.93 for the eight generic scales. In a test......OBJECTIVE: The questionnaire Kidney Disease Quality of Life Short Form version 1.3 (KDQOL-SF) is valuable for assessing the health-related quality of life in patients treated with chronic dialysis. The aim of this study was to translate and test the reliability of the KDQOL-SF for use in Denmark...... involving all patients, two of the disease-specific scales had Cronbach's alpha coefficients of test of the scores...

  12. Digital speckle correlation for nondestructive testing of corrosion

    Science.gov (United States)

    Paiva, Raul D., Jr.; Soga, Diogo; Muramatsu, Mikiya; Hogert, Elsa N.; Landau, Monica R.; Ruiz Gale, Maria F.; Gaggioli, Nestor G.

    1999-07-01

    This paper describes the use of optical correlation speckle patterns to detect and analyze the metallic corrosion phenomena, and shows the experimental set-up used. We present some new results in the characterization of the corrosion process using a model based in electroerosion phenomena. We also provide valuable information about surface microrelief changes, which is also useful in numerous engineering applications. The results obtained are good enough for showing that our technique is very useful for giving new possibilities to the analysis of the corrosion and oxidation process, particularly in real time.

  13. Correlation Analysis of Water Demand and Predictive Variables for Short-Term Forecasting Models

    Directory of Open Access Journals (Sweden)

    B. M. Brentan

    2017-01-01

    Full Text Available Operational and economic aspects of water distribution make water demand forecasting paramount for water distribution systems (WDSs management. However, water demand introduces high levels of uncertainty in WDS hydraulic models. As a result, there is growing interest in developing accurate methodologies for water demand forecasting. Several mathematical models can serve this purpose. One crucial aspect is the use of suitable predictive variables. The most used predictive variables involve weather and social aspects. To improve the interrelation knowledge between water demand and various predictive variables, this study applies three algorithms, namely, classical Principal Component Analysis (PCA and machine learning powerful algorithms such as Self-Organizing Maps (SOMs and Random Forest (RF. We show that these last algorithms help corroborate the results found by PCA, while they are able to unveil hidden features for PCA, due to their ability to cope with nonlinearities. This paper presents a correlation study of three district metered areas (DMAs from Franca, a Brazilian city, exploring weather and social variables to improve the knowledge of residential demand for water. For the three DMAs, temperature, relative humidity, and hour of the day appear to be the most important predictive variables to build an accurate regression model.

  14. Optical nonclassicality test based on third-order intensity correlations

    Science.gov (United States)

    Rigovacca, L.; Kolthammer, W. S.; Di Franco, C.; Kim, M. S.

    2018-03-01

    We develop a nonclassicality criterion for the interference of three delayed, but otherwise identical, light fields in a three-mode Bell interferometer. We do so by comparing the prediction of quantum mechanics with those of a classical framework in which independent sources emit electric fields with random phases. In particular, we evaluate third-order correlations among output intensities as a function of the delays, and show how the presence of a correlation revival for small delays cannot be explained by the classical model of light. The observation of a revival is thus a nonclassicality signature, which can be achieved only by sources with a photon-number statistics that is highly sub-Poissonian. Our analysis provides strong evidence for the nonclassicality of the experiment discussed by Menssen et al. [Phys. Rev. Lett. 118, 153603 (2017), 10.1103/PhysRevLett.118.153603], and shows how a collective "triad" phase affects the interference of any three or more light fields, irrespective of their quantum or classical character.

  15. Correlation of Flammability Test Data on Antimisting Fuels.

    Science.gov (United States)

    1982-12-01

    relative air-to-liquid velocity) decay during the course of single test runs. The basic informa- tion on pitot tube dynamic pressure decays and...1961). 2. K. J. DeJuhasz, Spray Literature Abstracts, Volumes I-IV, American Soc. Mechanical Engineers (1959-1969). 3. C. E. Lapple, J.P. Henry , and

  16. Hemispheric Correlates of the Rod-And-Frame Test.

    Science.gov (United States)

    Berlin, Donna F.; Languis, Marlin L.

    1981-01-01

    Right-handed sixth graders were administered the WISC Block Design and verbal and nonverbal versions of the Rod-and-Frame Test (RFT), measuring field dependence/independence. Results seemed to reflect a right hemisphere processing for the nonverbal RFT and a possible sex bias against girls in its traditional verbal administration. (Author/SJL)

  17. Correlated individual differences suggest a common mechanism underlying metacognition in visual perception and visual short-term memory.

    Science.gov (United States)

    Samaha, Jason; Postle, Bradley R

    2017-11-29

    Adaptive behaviour depends on the ability to introspect accurately about one's own performance. Whether this metacognitive ability is supported by the same mechanisms across different tasks is unclear. We investigated the relationship between metacognition of visual perception and metacognition of visual short-term memory (VSTM). Experiments 1 and 2 required subjects to estimate the perceived or remembered orientation of a grating stimulus and rate their confidence. We observed strong positive correlations between individual differences in metacognitive accuracy between the two tasks. This relationship was not accounted for by individual differences in task performance or average confidence, and was present across two different metrics of metacognition and in both experiments. A model-based analysis of data from a third experiment showed that a cross-domain correlation only emerged when both tasks shared the same task-relevant stimulus feature. That is, metacognition for perception and VSTM were correlated when both tasks required orientation judgements, but not when the perceptual task was switched to require contrast judgements. In contrast with previous results comparing perception and long-term memory, which have largely provided evidence for domain-specific metacognitive processes, the current findings suggest that metacognition of visual perception and VSTM is supported by a domain-general metacognitive architecture, but only when both domains share the same task-relevant stimulus feature. © 2017 The Author(s).

  18. Do Standardized Tests Penalize Deep-Thinking, Creative, or Conscientious Students?: Some Personality Correlates of Graduate Record Examinations Test Scores

    Science.gov (United States)

    Powers, Donald E.; Kaufman, James C.

    2004-01-01

    The objective of the study reported here was to explore the relationship of Graduate Record Examinations (GRE) General Test scores to selected personality traits--conscientiousness, rationality, ingenuity, quickness, creativity, and depth. A sample of 342 GRE test takers completed short personality inventory scales for each trait. Analyses…

  19. correlation with µCT and biomechanical testing

    OpenAIRE

    Kentenich, Marie

    2013-01-01

    Purpose: Assessment of trabecular bone structure may enhance estimation of biomechanical strength and therefore improve diagnostic standards for osteoporosis. Still visualization of the trabecular microstructure in vivo is challenging. We tested the feasibility of assessing trabecular bone structure for evaluation of bone quality on intact human cadavers using multidetector CT (MDCT) in an experimental in situ and therefore simulated in vivo setup. Methods: Bone structure (BV/TV: ...

  20. Psychometric testing of the properties of the spiritual health scale short form.

    Science.gov (United States)

    Hsiao, Ya-Chu; Chiang, Yi-Chien; Lee, Hsiang-Chun; Han, Chin-Yen

    2013-11-01

    To further examine the psychometric properties of the spiritual health scale short form, including its reliability and validity. Spirituality is one of the main factors associated with good health outcomes. A reliable and valid instrument to measure spirituality is essential to identify the spiritual needs of an individual and to evaluate the effect of spiritual care. A cross-sectional study design was used. The study was conducted in six nursing schools in northern, central and southern Taiwan. The inclusion criterion for participants was nursing students with clinical practice experience. Initially, 1141 participants were recruited for the study, but 67 were absent and 48 did not complete the questionnaires. A total of 1026 participants were finally recruited, indicating a response rate of 89·9%. The psychometric testing of the spiritual health scale short form included construct validity with confirmatory factor analysis, known-group validity and internal consistency reliability. The results of the confirmatory factor analysis supported the five-factor model as an acceptable model fit. In the known-group validity, the results indicated that people who are in the category of primary religious affiliation have better spiritual health than people in the category of secondary religious affiliation and atheism. The result also indicated that the 24-item spiritual health scale short form achieved an acceptable internal consistency coefficient. The findings suggest that the spiritual health scale short form is a valid and reliable instrument for the appraisal of individual spiritual health. The spiritual health scale short form could provide useful information to guide clinical practice in assessing and managing people's spiritual health in Taiwan. © 2013 John Wiley & Sons Ltd.

  1. Modified SPC for short run test and measurement process in multi-stations

    Science.gov (United States)

    Koh, C. K.; Chin, J. F.; Kamaruddin, S.

    2018-03-01

    Due to short production runs and measurement error inherent in electronic test and measurement (T&M) processes, continuous quality monitoring through real-time statistical process control (SPC) is challenging. Industry practice allows the installation of guard band using measurement uncertainty to reduce the width of acceptance limit, as an indirect way to compensate the measurement errors. This paper presents a new SPC model combining modified guard band and control charts (\\bar{\\text{Z}} chart and W chart) for short runs in T&M process in multi-stations. The proposed model standardizes the observed value with measurement target (T) and rationed measurement uncertainty (U). S-factor (S f) is introduced to the control limits to improve the sensitivity in detecting small shifts. The model was embedded in automated quality control system and verified with a case study in real industry.

  2. Within-day variability on short and long walking tests in persons with multiple sclerosis.

    Science.gov (United States)

    Feys, Peter; Bibby, Bo; Romberg, Anders; Santoyo, Carme; Gebara, Benoit; de Noordhout, Benoit Maertens; Knuts, Kathy; Bethoux, Francois; Skjerbæk, Anders; Jensen, Ellen; Baert, Ilse; Vaney, Claude; de Groot, Vincent; Dalgas, Ulrik

    2014-03-15

    To compare within-day variability of short (10 m walking test at usual and fastest speed; 10MWT) and long (2 and 6-minute walking test; 2MWT/6MWT) tests in persons with multiple sclerosis. Observational study. MS rehabilitation and research centers in Europe and US within RIMS (European network for best practice and research in MS rehabilitation). Ambulatory persons with MS (Expanded Disability Status Scale 0-6.5). Subjects of different centers performed walking tests at 3 time points during a single day. 10MWT, 2MWT and 6MWT at fastest speed and 10MWT at usual speed. Ninety-five percent limits of agreement were computed using a random effects model with individual pwMS as random effect. Following this model, retest scores are with 95% certainty within these limits of baseline scores. In 102 subjects, within-day variability was constant in absolute units for the 10MWT, 2MWT and 6MWT at fastest speed (+/-0.26, 0.16 and 0.15m/s respectively, corresponding to +/-19.2m and +/-54 m for the 2MWT and 6MWT) independent on the severity of ambulatory dysfunction. This implies a greater relative variability with increasing disability level, often above 20% depending on the applied test. The relative within-day variability of the 10MWT at usual speed was +/-31% independent of ambulatory function. Absolute values of within-day variability on walking tests at fastest speed were independent of disability level and greater with short compared to long walking tests. Relative within-day variability remained overall constant when measured at usual speed. Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.

  3. EEG correlates of visual short-term memory in older age vary with adult lifespan cognitive development

    DEFF Research Database (Denmark)

    Wiegand, Iris; Lauritzen, Martin J.; Osler, Merete

    2018-01-01

    Visual short-term memory (vSTM) is a cognitive resource that declines with age. This study investigated whether electroencephalography (EEG) correlates of vSTM vary with cognitive development over individuals' lifespan. We measured vSTM performance and EEG in a lateralized whole-report task...... in a healthy birth cohort, whose cognitive function (intelligence quotient) was assessed in youth and late-middle age. Higher vSTM capacity (K; measured by Bundesen's theory of visual attention) was associated with higher amplitudes of the contralateral delay activity (CDA) and the central positivity (CP......). In addition, rightward hemifield asymmetry of vSTM (Kλ) was associated with lower CDA amplitudes. Furthermore, more severe cognitive decline from young adulthood to late-middle age predicted higher CDA amplitudes, and the relationship between K and the CDA was less reliable in individuals who show higher...

  4. Low serum transferrin correlates with acute-on-chronic organ failure and indicates short-term mortality in decompensated cirrhosis.

    Science.gov (United States)

    Bruns, Tony; Nuraldeen, Renwar; Mai, Martina; Stengel, Sven; Zimmermann, Henning W; Yagmur, Eray; Trautwein, Christian; Stallmach, Andreas; Strnad, Pavel

    2017-02-01

    Iron represents an essential, but potentially harmful micronutrient, whose regulation has been associated with poor outcome in liver disease. Its homeostasis is tightly linked to oxidative stress, bacterial infections and systemic inflammation. To study the prognostic short-term significance of iron parameters in a cohort study of patients with decompensation of cirrhosis at risk of acute-on-chronic liver failure (ACLF). Ferritin, transferrin, iron, transferrin saturation (TSAT) and hepcidin were determined in sera from 292 German patients hospitalized for decompensation of cirrhosis with ascites, of which 78 (27%) had ACLF. Short-term mortality was prospectively assessed 30 and 90 days after inclusion. Transferrin concentrations were significantly lower, whereas ferritin and TSAT were higher in patients with ACLF compared to patients without ACLF (P≤.006). Transferrin, TSAT and ferritin differentially correlated with the severity of organ failure, active alcoholism and surrogates of systemic inflammation and macrophage activation. As compared with survivors, 30-day non-survivors displayed lower serum transferrin (P=.0003) and higher TSAT (P=.003), whereas 90-day non-survivors presented with higher ferritin (P=.03) and lower transferrin (P=.02). Lower transferrin (continuous or dichotomized at 87 mg/dL) and consecutively higher TSAT (continuous or dichotomized >41%) indicated increased mortality within 30 days and remained significant after adjustment for organ failure and inflammation in multivariate regression models and across subgroups of patients. Among the investigated indicators of iron metabolism, serum transferrin concentration was the best indicator of organ failure and an independent predictor of short-term mortality at 30 days. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Short-range correlations control the G/K and Poisson ratios of amorphous solids and metallic glasses

    Energy Technology Data Exchange (ETDEWEB)

    Zaccone, Alessio; Terentjev, Eugene M. [Cavendish Laboratory, University of Cambridge, JJ Thomson Avenue, Cambridge CB3 0HE (United Kingdom)

    2014-01-21

    The bulk modulus of many amorphous materials, such as metallic glasses, behaves nearly in agreement with the assumption of affine deformation, namely that the atoms are displaced just by the amount prescribed by the applied strain. In contrast, the shear modulus behaves as for nonaffine deformations, with additional displacements due to the structural disorder which induce a marked material softening to shear. The consequence is an anomalously large ratio of the bulk modulus to the shear modulus for disordered materials characterized by dense atomic packing, but not for random networks with point atoms. We explain this phenomenon with a microscopic derivation of the elastic moduli of amorphous solids accounting for the interplay of nonaffinity and short-range particle correlations due to excluded volume. Short-range order is responsible for a reduction of the nonaffinity which is much stronger under compression, where the geometric coupling between nonaffinity and the deformation field is strong, whilst under shear this coupling is weak. Predictions of the Poisson ratio based on this model allow us to rationalize the trends as a function of coordination and atomic packing observed with many amorphous materials.

  6. Engineering scale tests of mechanical disassembly and short stroke shearing systems for FBR fuel assembly

    International Nuclear Information System (INIS)

    Higuchi, Hidetoshi; Kitagaki, Toru; Koizumi, Kenji; Hirano, Hiroyasu; Takeuchi, Masayuki; Washiya, Tadahiro; Kawabe, Yukinari; Kobayashi, Tsuguyuki

    2011-01-01

    Japan Atomic Energy Agency (JAEA) and The Japan Atomic Power Company (JAPC) have been developing an advanced head-end process based on mechanical disassembly and short stroke shearing systems as a part of Fast Reactor Cycle Technology Development (FaCT). Fuel pins for a fast reactor are installed within a hexagonal shaped wrapper tube made of stainless steel. In order to reprocess the fast reactor fuel pins, they must be removed from the wrapper tube and transported to the shearing system without failure. In addition, the advanced aqueous reprocessing process, called 'NEXT' (New Extraction System for TRU Recovery) process requires a solution of the spent fuel with relatively high concentration (500g/L). JAEA and JAPC have developed the mechanical disassembly and the short stroke shearing technology which is expected to make fragmented fuel to satisfy these requirements. This paper reports the results of engineering scale tests on the mechanical disassembly and short stroke shearing systems. These tests were carried out with simulated FBR fuel assembly and removed pins. The mechanical cutting method has been developed to avoid fuel pin failure during disassembly operation. The cutting process is divided into two modes, so called 'slit-cut' for cutting the wrapper tube and 'crop-cut' for the end plug region of the fuel pin bundle. In the slit-cut mode, the depth of cutting was automatically controlled based on the calculated wastage of the cutting tool and deformation of the wrapper tube which had been measured before the cutting. This procedure was confirmed to minimize the fuel pin failure which was hard to prevent in the case of laser cutting. The cutting speed was also controlled automatically by the electric current of the cutting motor to lower the load of the cutting tool. The removed fuel pins were transported to the shearing machine, whose fuel shearing magazine width was set to be narrow to realize the suitable configuration for the short stroke shearing

  7. Statistical correlation of structural mode shapes from test measurements and NASTRAN analytical values

    Science.gov (United States)

    Purves, L.; Strang, R. F.; Dube, M. P.; Alea, P.; Ferragut, N.; Hershfeld, D.

    1983-01-01

    The software and procedures of a system of programs used to generate a report of the statistical correlation between NASTRAN modal analysis results and physical tests results from modal surveys are described. Topics discussed include: a mathematical description of statistical correlation, a user's guide for generating a statistical correlation report, a programmer's guide describing the organization and functions of individual programs leading to a statistical correlation report, and a set of examples including complete listings of programs, and input and output data.

  8. Hall Thruster Thermal Modeling and Test Data Correlation

    Science.gov (United States)

    Myers, James

    2016-01-01

    HERMeS - Hall Effect Rocket with Magnetic Shielding. Developed through a joint effort by NASA/GRC and the Jet Propulsion Laboratory (JPL). Design goals: High power (12.5 kW) high Isp (3000 sec), high efficiency (> 60%), high throughput (10,000 kg), reduced plasma erosion and increased life (5 yrs) to support Asteroid Redirect Robotic Mission (ARRM). Further details see "Performance, Facility Pressure Effects and Stability Characterization Tests of NASAs HERMeS Thruster" by H. Kamhawi and team. Hall Thrusters (HT) inherently operate at elevated temperatures approx. 600 C (or more). Due to electric magnetic (E x B) fields used to ionize and accelerate propellant gas particles (i.e., plasma). Cooling is largely limited to radiation in vacuum environment.Thus the hardware components must withstand large start-up delta-T's. HT's are constructed of multiple materials; assorted metals, non-metals and ceramics for their required electrical and magnetic properties. To mitigate thermal stresses HT design must accommodate the differential thermal growth from a wide range of material Coef. of Thermal Expansion (CTEs). Prohibiting the use of some bolted/torqued interfaces.Commonly use spring loaded interfaces, particularly at the metal-to-ceramic interfaces to allow for slippage.However most component interfaces must also effectively conduct heat to the external surfaces for dissipation by radiation.Thus contact pressure and area are important.

  9. Design and test of a short mockup magnet for the superconducting undulator at the SSRF

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Jieping, E-mail: jpxu@sinap.ac.cn; Ding, Yi; Cui, Jian; Zhang, Wei; Wang, Hongfei; Yin, Lixin [Department of Mechanical Engineering, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201204 (China)

    2016-07-27

    A superconducting planar undulator is under development at the Shanghai Synchrotron Radiation Facility (SSRF) to provide the SSRF users with higher photon fluxes at higher photon energies. A 5-period magnet was designed and built for feasibility study. The short mockup magnet is composed of NbTi/Cu winding and low carbon steel former and was tested in a vertical cryocooler-cooled cryostat. The nominal current of 387 A was reached after 2 quenches and the maximum current of 433.2 A was achieved. The magnetic field profile was measured and a peak field of 0.93 T was obtained when stably operating at 400 A.

  10. Two-photon collisions and short-distance tests of quantum chromodynamics

    International Nuclear Information System (INIS)

    Brodsky, S.J.

    1978-12-01

    The physics of two-photon collisions in e +- storage rings is reviewed with emphasis on the predictions of perturbative quantum chromodynamics for high transverse momentum reactions. It is noted that because of the remarkable scaling properties predicted by the theory, two-photon collisions may be proved one of the cleanest tests of the quantum chromodynamics picture of short distance hadron dynamics. In order to contrast these predictions for photon-induced reactions with those for incident hadrons, predictions from quantum chromodynamics for hadron structure functions and form factors at large momentum transfer are also discussed. 55 references

  11. Correlation Results for a Mass Loaded Vehicle Panel Test Article Finite Element Models and Modal Survey Tests

    Science.gov (United States)

    Maasha, Rumaasha; Towner, Robert L.

    2012-01-01

    High-fidelity Finite Element Models (FEMs) were developed to support a recent test program at Marshall Space Flight Center (MSFC). The FEMs correspond to test articles used for a series of acoustic tests. Modal survey tests were used to validate the FEMs for five acoustic tests (a bare panel and four different mass-loaded panel configurations). An additional modal survey test was performed on the empty test fixture (orthogrid panel mounting fixture, between the reverb and anechoic chambers). Modal survey tests were used to test-validate the dynamic characteristics of FEMs used for acoustic test excitation. Modal survey testing and subsequent model correlation has validated the natural frequencies and mode shapes of the FEMs. The modal survey test results provide a basis for the analysis models used for acoustic loading response test and analysis comparisons

  12. The role of the form factor and short-range correlation in the relativistic Hartree-Fock model for nuclear matter

    International Nuclear Information System (INIS)

    Hu, J.; Toki, H.; Wen, W.; Shen, H.

    2010-01-01

    The role of the form factor and short-range correlation in nuclear matter is studied within the relativistic Hartree-Fock approximation. We take, first, the mean-field approximation for meson fields and obtain the fluctuation terms of mesons to be used for the Fock energies. We introduce form factors in the meson-nucleon coupling vertices to take into account the finite-size effect of the nucleon. We use further the unitary correlation operator method for the treatment of the short-range correlation. The form factors of the size (Λ∝1.0 -2.0 GeV) of the nucleon-nucleon interaction cut down largely the contribution of the ρ-meson in the Fock term. The short-range correlation effect is not large but has a significant effect on the pion and ρ-meson energies in the relativistic Hartree-Fock approximation for nuclear matter. (orig.)

  13. The role of the form factor and short-range correlation in the relativistic Hartree-Fock model for nuclear matter

    Science.gov (United States)

    Hu, J.; Toki, H.; Wen, W.; Shen, H.

    2010-03-01

    The role of the form factor and short-range correlation in nuclear matter is studied within the relativistic Hartree-Fock approximation. We take, first, the mean-field approximation for meson fields and obtain the fluctuation terms of mesons to be used for the Fock energies. We introduce form factors in the meson-nucleon coupling vertices to take into account the finite-size effect of the nucleon. We use further the unitary correlation operator method for the treatment of the short-range correlation. The form factors of the size ( Λ ˜ 1.0 -2.0GeV) of the nucleon-nucleon interaction cut down largely the contribution of the ρ -meson in the Fock term. The short-range correlation effect is not large but has a significant effect on the pion and ρ -meson energies in the relativistic Hartree-Fock approximation for nuclear matter.

  14. Effects of acute caffeine withdrawal on Short Category Test performance in sleep-deprived individuals.

    Science.gov (United States)

    Killgore, William D S; Kahn-Greene, Ellen T; Killgore, Desiree B; Kamimori, Gary H; Balkin, Thomas J

    2007-12-01

    Caffeine is a popular stimulant often used to counter the effects of sleep loss and fatigue. Withdrawal from caffeine may produce mild declines in simple cognitive capacities such as attention and concentration, but it is unclear whether more complex cognitive functions, such as abstract reasoning or concept formation, may be similarly affected. To assess the effect of acute caffeine withdrawal on executive functioning during sleep deprivation, 26 healthy volunteers were administered in double-blind form either repeated doses of caffeine or placebo over two nights of continuous wakefulness. The 108-item Short Category Test was administered after 56 hr. of total sleep deprivation (9 hr. post-caffeine administration). The caffeine group scored significantly more poorly, making approximately 57% more errors on the test than the placebo group. These findings suggest that acute caffeine withdrawal during prolonged sleep deprivation has an adverse effect on abstract reasoning and concept formation.

  15. Validity of a new assessment rubric for a short-answer test of clinical reasoning.

    Science.gov (United States)

    Yeung, Euson; Kulasagarem, Kulamakan; Woods, Nicole; Dubrowski, Adam; Hodges, Brian; Carnahan, Heather

    2016-07-26

    The validity of high-stakes decisions derived from assessment results is of primary concern to candidates and certifying institutions in the health professions. In the field of orthopaedic manual physical therapy (OMPT), there is a dearth of documented validity evidence to support the certification process particularly for short-answer tests. To address this need, we examined the internal structure of the Case History Assessment Tool (CHAT); this is a new assessment rubric developed to appraise written responses to a short-answer test of clinical reasoning in post-graduate OMPT certification in Canada. Fourteen physical therapy students (novices) and 16 physical therapists (PT) with minimal and substantial OMPT training respectively completed a mock examination. Four pairs of examiners (n = 8) participated in appraising written responses using the CHAT. We conducted separate generalizability studies (G studies) for all participants and also by level of OMPT training. Internal consistency was calculated for test questions with more than 2 assessment items. Decision studies were also conducted to determine optimal application of the CHAT for OMPT certification. The overall reliability of CHAT scores was found to be moderate; however, reliability estimates for the novice group suggest that the scale was incapable of accommodating for scores of novices. Internal consistency estimates indicate item redundancies for several test questions which will require further investigation. Future validity studies should consider discriminating the clinical reasoning competence of OMPT trainees strictly at the post-graduate level. Although rater variance was low, the large variance attributed to error sources not incorporated in our G studies warrant further investigations into other threats to validity. Future examination of examiner stringency is also warranted.

  16. Correlation between two parameters of mice behaviour in the open field test

    OpenAIRE

    Stojanović, Nikola M.; Ranđelović, Pavle J.; Radulović, Niko S.

    2017-01-01

    The open field test is being used extensively for the determination of different aspects of animal behaviour for over seventy years. The correlation between different behavioural parameters obtained in this test, although previously studied, is still debatable. Thus, we aimed to analyze and correlate behaviour scores to estimate the importance of individual parameters in this type of experiment. The open field test was performed on male BALB/c mice treated with either saline (10 ml/kg) or dia...

  17. Review of short-term screening tests for mutagens, toxigens, and carcinogens

    Energy Technology Data Exchange (ETDEWEB)

    Carney, H.J.; Hass, B.S.

    1979-07-01

    In order to test the thousands of man-made chemicals in the environment for carcinogenic and genetic hazards, a multitude of short-term screening tests has been developed to complement long-term mammalian bioassays and epidemiological studies. These tests cover a broad spectrum of organisms, and include the use of naked and viral nucleic acids, bacteria, fungi, higher plants, insects in vitro mammalian cell cultures (cell transformation, cell-mediated mutagenesis, DNA repair, and chromosome aberration tests) and live mammals. Assay end points include effects on nucleic acids, DNA repair synthesis, point or gene mutation, structural and numerical chromosome aberrations, cytological alterations, and in vitro cell transformation. The present review describes and compares these assays. In addition, it discusses their historical development, the problems and limitations associated with their use, and their implementation in comprehensive testing programs. It is intended to provide overview and specific information to the laboratory that is in the process of establishing genetic toxicological systems. (The literature is reviewed to January 1978.)

  18. Empirical versus Random Item Selection in the Design of Intelligence Test Short Forms--The WISC-R Example.

    Science.gov (United States)

    Goh, David S.

    1979-01-01

    The advantages of using psychometric thoery to design short forms of intelligence tests are demonstrated by comparing such usage to a systematic random procedure that has previously been used. The Wechsler Intelligence Scale for Children Revised (WISC-R) Short Form is presented as an example. (JKS)

  19. The quadratic relationship between difficulty of intelligence test items and their correlations with working memory

    Directory of Open Access Journals (Sweden)

    Tomasz eSmoleń

    2015-08-01

    Full Text Available Fluid intelligence (Gf is a crucial cognitive ability that involves abstract reasoning in order to solve novel problems. Recent research demonstrated that Gf strongly depends on the individual effectiveness of working memory (WM. We investigated a popular claim that if the storage capacity underlay the WM-Gf correlation, then such a correlation should increase with an increasing number of items or rules (load in a Gf test. As often no such link is observed, on that basis the storage-capacity account is rejected, and alternative accounts of Gf (e.g., related to executive control or processing speed are proposed. Using both analytical inference and numerical simulations, we demonstrated that the load-dependent change in correlation is primarily a function of the amount of floor/ceiling effect for particular items. Thus, the item-wise WM correlation of a Gf test depends on its overall difficulty, and the difficulty distribution across its items. When the early test items yield huge ceiling, but the late items do not approach floor, that correlation will increase throughout the test. If the early items locate themselves between ceiling and floor, but the late items approach floor, the respective correlation will decrease. For a hallmark Gf test, the Raven test, whose items span from ceiling to floor, the quadratic relationship is expected, and it was shown empirically using a large sample and two types of WMC tasks. In consequence, no changes in correlation due to varying WM/Gf load, or lack of them, can yield an argument for or against any theory of WM/Gf. Moreover, as the mathematical properties of the correlation formula make it relatively immune to ceiling/floor effects for overall moderate correlations, only minor changes (if any in the WM-Gf correlation should be expected for many psychological tests.

  20. The quadratic relationship between difficulty of intelligence test items and their correlations with working memory.

    Science.gov (United States)

    Smolen, Tomasz; Chuderski, Adam

    2015-01-01

    Fluid intelligence (Gf) is a crucial cognitive ability that involves abstract reasoning in order to solve novel problems. Recent research demonstrated that Gf strongly depends on the individual effectiveness of working memory (WM). We investigated a popular claim that if the storage capacity underlay the WM-Gf correlation, then such a correlation should increase with an increasing number of items or rules (load) in a Gf-test. As often no such link is observed, on that basis the storage-capacity account is rejected, and alternative accounts of Gf (e.g., related to executive control or processing speed) are proposed. Using both analytical inference and numerical simulations, we demonstrated that the load-dependent change in correlation is primarily a function of the amount of floor/ceiling effect for particular items. Thus, the item-wise WM correlation of a Gf-test depends on its overall difficulty, and the difficulty distribution across its items. When the early test items yield huge ceiling, but the late items do not approach floor, that correlation will increase throughout the test. If the early items locate themselves between ceiling and floor, but the late items approach floor, the respective correlation will decrease. For a hallmark Gf-test, the Raven-test, whose items span from ceiling to floor, the quadratic relationship is expected, and it was shown empirically using a large sample and two types of WMC tasks. In consequence, no changes in correlation due to varying WM/Gf load, or lack of them, can yield an argument for or against any theory of WM/Gf. Moreover, as the mathematical properties of the correlation formula make it relatively immune to ceiling/floor effects for overall moderate correlations, only minor changes (if any) in the WM-Gf correlation should be expected for many psychological tests.

  1. The Leeb Hardness Test for Rock: An Updated Methodology and UCS Correlation

    Science.gov (United States)

    Corkum, A. G.; Asiri, Y.; El Naggar, H.; Kinakin, D.

    2018-03-01

    The Leeb hardness test (LHT with test value of L D ) is a rebound hardness test, originally developed for metals, that has been correlated with the Unconfined Compressive Strength (test value of σ c ) of rock by several authors. The tests can be carried out rapidly, conveniently and nondestructively on core and block samples or on rock outcrops. This makes the relatively small LHT device convenient for field tests. The present study compiles test data from literature sources and presents new laboratory testing carried out by the authors to develop a substantially expanded database with wide-ranging rock types. In addition, the number of impacts that should be averaged to comprise a "test result" was revisited along with the issue of test specimen size. Correlation for L D and σ c for various rock types is provided along with recommended testing methodology. The accuracy of correlated σ c estimates was assessed and reasonable correlations were observed between L D and σ c . The study findings show that LHT can be useful particularly for field estimation of σ c and offers a significant improvement over the conventional field estimation methods outlined by the ISRM (e.g., hammer blows). This test is rapid and simple, with relatively low equipment costs, and provides a reasonably accurate estimate of σ c .

  2. Relationship between physiological indices and aerobic performance tests in short and medium term of elite cyclists

    Directory of Open Access Journals (Sweden)

    Eduardo Bernardo Sangali

    2013-05-01

    Full Text Available Few studies allow usto verify which physiological responses are associated with performance in anational elite cycling group. Therefore, this study aimed to determine and correlate various physiological and aerobic indices with performance in 4 and 20 km time trials in high-level cyclists. The sample consisted of 14 male professional cyclists of the national elite group (28.5 ± 4.7 years old, 73.47 ± 8.29 kg, 176 ± 6.76cm, who performed a progressive test in laboratory to determine maximal oxygen consumption (VO2max: 62.23 ± 8.28 ml•kg-1•min-1, intensity relative to VO2max(iVO2max: 500.83 ± 58.65w, movement economy (EM: 0.1166 ± 0.0362 ml•kg•min•w-1, and the first and second ventilatory threshold (LV1: 348.21 ±43.26 w; LV2: 417.86 ± 60.79 w, respectively. They also performed two time trial performance tests of 4 and 20km. For the correlation between physiological indices and trial performance, Pearson correlation coefficient(p< 0.05 was used. No correlation was found between the physiological indices (VO2max absolute and relative, iVO2max, EM, LV1 and LV2 andperformance in 4 km (r= 0.38; 0.16; -0.33; 0.20; -0.50; -0.20, respectivelyand 20 km (r= 0.24; 0.01; -0.13; -0.12; -0.48; -0.19, respectively time trialin high level athletes. These results suggest that these variables are not able to explain the performance in time trials in the respective lengths, probably due to the subjects’ homogeneity.

  3. Short-Run Contexts and Imperfect Testing for Continuous Sampling Plans

    Directory of Open Access Journals (Sweden)

    Mirella Rodriguez

    2018-04-01

    Full Text Available Continuous sampling plans are used to ensure a high level of quality for items produced in long-run contexts. The basic idea of these plans is to alternate between 100% inspection and a reduced rate of inspection frequency. Any inspected item that is found to be defective is replaced with a non-defective item. Because not all items are inspected, some defective items will escape to the customer. Analytical formulas have been developed that measure both the customer perceived quality and also the level of inspection effort. The analysis of continuous sampling plans does not apply to short-run contexts, where only a finite-size batch of items is to be produced. In this paper, a simulation algorithm is designed and implemented to analyze the customer perceived quality and the level of inspection effort for short-run contexts. A parameter representing the effectiveness of the test used during inspection is introduced to the analysis, and an analytical approximation is discussed. An application of the simulation algorithm that helped answer questions for the U.S. Navy is discussed.

  4. Short-term stability test for thorium soil candidate a reference material

    Energy Technology Data Exchange (ETDEWEB)

    Clain, Almir F.; Fonseca, Adelaide M.G.; Dantas, Vanessa V.D.B.; Braganca, Maura J.C.; Souza, Poliana S., E-mail: almir@ird.gov.br, E-mail: adelaide@ird.gov.br, E-mail: vanessa@ird.gov.br, E-mail: maura@ird.gov.br, E-mail: poliana@bolsista.ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    This work describes a methodology to determine the soil short-term stability after the steps of production in laboratory. The short-term stability of the soil is an essential property to be determined in order to producing a reference material. The soil is a candidate of reference material for chemical analysis of thorium with metrological traceability to be used in environmental analysis, equipment calibration, validation methods, and quality control. A material is considered stable in a certain temperature if the property of interest does not change with time, considering the analytical random fluctuations. Due to this, the angular coefficient from the graphic of Th concentration versus elapsed time must be near to zero. The analytical determinations of thorium concentration were performed by Instrumental Neutron activation Analysis. The slopes and their uncertainties were obtained from the regression lines at temperatures of 20 deg C and 60 deg C, with control temperature of -20 deg C. From the obtained data a t-test was applied. In both temperatures the calculated t-value was lower than the critical value, so we can conclude with 95% confidence level that no significant changes happened during the period studied concerning thorium concentration in soil at temperatures of 20 deg C and 60 deg C, showing stability at these temperatures. (author)

  5. Short-circuit testing of monofilar Bi-2212 coils connected in series and in parallel

    International Nuclear Information System (INIS)

    Polasek, A; Dias, R; Serra, E T; Filho, O O; Niedu, D

    2010-01-01

    Superconducting Fault Current Limiters (SCFCL's) are one of the most promising technologies for fault current limitation. In the present work, resistive SCFCL components based on Bi-2212 monofilar coils are subjected to short-circuit testing. These SCFCL components can be easily connected in series and/or in parallel by using joints and clamps. This allows a considerable flexibility to developing larger SCFCL devices, since the configuration and size of the whole device can be easily adapted to the operational conditions. The single components presented critical current (Ic) values of 240-260 A, at 77 K. Short-circuits during 40-120 ms were applied. A single component can withstand a voltage drop of 126-252 V (0.3-0.6 V/cm). Components connected in series withstand higher voltage levels, whereas parallel connection allows higher rated currents during normal operation, but the limited current is also higher. Prospective currents as high as 10-40 kA (peak value) were limited to 3-9 kA (peak value) in the first half cycle.

  6. Short-term stability test for thorium soil candidate a reference material

    International Nuclear Information System (INIS)

    Clain, Almir F.; Fonseca, Adelaide M.G.; Dantas, Vanessa V.D.B.; Braganca, Maura J.C.; Souza, Poliana S.

    2015-01-01

    This work describes a methodology to determine the soil short-term stability after the steps of production in laboratory. The short-term stability of the soil is an essential property to be determined in order to producing a reference material. The soil is a candidate of reference material for chemical analysis of thorium with metrological traceability to be used in environmental analysis, equipment calibration, validation methods, and quality control. A material is considered stable in a certain temperature if the property of interest does not change with time, considering the analytical random fluctuations. Due to this, the angular coefficient from the graphic of Th concentration versus elapsed time must be near to zero. The analytical determinations of thorium concentration were performed by Instrumental Neutron activation Analysis. The slopes and their uncertainties were obtained from the regression lines at temperatures of 20 deg C and 60 deg C, with control temperature of -20 deg C. From the obtained data a t-test was applied. In both temperatures the calculated t-value was lower than the critical value, so we can conclude with 95% confidence level that no significant changes happened during the period studied concerning thorium concentration in soil at temperatures of 20 deg C and 60 deg C, showing stability at these temperatures. (author)

  7. A Methodological Approach for Testing the Viability of Seeds Stored in Short-Term Seed Banks

    Directory of Open Access Journals (Sweden)

    Jose A. FORTE GIL

    2017-12-01

    Full Text Available Efficient management of ‘active’ seed banks – specifically aimed at the short-term storage at room temperature of seeds to be used locally in conservation/regeneration programmes of endemic or endangered plant species – requires establishing the optimal storage time to maintain high seed viability, for each stored species. In this work, germination of seeds of the halophytes Thalictrum maritimum, Centaurea dracunculifolia and Linum maritimum has been investigated. The seeds had been stored for different periods of time in the seed bank of ‘La Albufera’ Natural Park (Valencia, SE Spain after collection in salt marshes of the Park, where small populations of the three species are present. Seeds of T. maritimum and C. dracunculifolia have a relatively short period of viability at room temperature, and should not be stored for more than three years. On the other hand, L. maritimum seeds maintain a high germination percentage and can be kept at room temperature for up to 10 years. T. maritimum seeds, in contrast to those of the other two species, did not germinate in in vitro tests nor when sown directly on a standard substrate, unless a pre-treatment of the seeds was applied, mechanical scarification being the most effective. These results will help to improve the management of the seed bank, to generate more efficiently new plants for reintroduction and reinforcement of populations of these species in their natural ecosystems within the Natural Park.

  8. EEG correlates of visual short-term memory in older age vary with adult lifespan cognitive development.

    Science.gov (United States)

    Wiegand, Iris; Lauritzen, Martin J; Osler, Merete; Mortensen, Erik Lykke; Rostrup, Egill; Rask, Lene; Richard, Nelly; Horwitz, Anna; Benedek, Krisztina; Vangkilde, Signe; Petersen, Anders

    2018-02-01

    Visual short-term memory (vSTM) is a cognitive resource that declines with age. This study investigated whether electroencephalography (EEG) correlates of vSTM vary with cognitive development over individuals' lifespan. We measured vSTM performance and EEG in a lateralized whole-report task in a healthy birth cohort, whose cognitive function (intelligence quotient) was assessed in youth and late-middle age. Higher vSTM capacity (K; measured by Bundesen's theory of visual attention) was associated with higher amplitudes of the contralateral delay activity (CDA) and the central positivity (CP). In addition, rightward hemifield asymmetry of vSTM (K λ ) was associated with lower CDA amplitudes. Furthermore, more severe cognitive decline from young adulthood to late-middle age predicted higher CDA amplitudes, and the relationship between K and the CDA was less reliable in individuals who show higher levels of cognitive decline compared to individuals with preserved abilities. By contrast, there was no significant effect of lifespan cognitive changes on the CP or the relationship between behavioral measures of vSTM and the CP. Neither the CDA, nor the CP, nor the relationships between K or K λ and the event-related potentials were predicted by individuals' current cognitive status. Together, our findings indicate complex age-related changes in processes underlying behavioral and EEG measures of vSTM and suggest that the K-CDA relationship might be a marker of cognitive lifespan trajectories. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Correlation between short-range order, optical properties and UV-absorption ability in tellurate glasses; Poster M7

    Energy Technology Data Exchange (ETDEWEB)

    Burger, H; Tews, W; Vogel, W; Kozhukharov, V [Jena Univ. (Germany)

    1989-01-01

    Tellurate glasses, with as second components Al[sub 2]O[sub 3], PbO, PbF[sub 2], PbCl[sub 2], PbBr[sub 2], PbSO[sub 4], ZnO, B[sub 2]O[sub 3], P[sub 2]O[sub 5], Li[sub 2]O, Na[sub 2]O, K[sub 2]O, MgO and BaO as well as some glasses from ternary TeO[sub 2]-P[sub 2]O[sub 5]-RO systems (R is Pb, Ba and Zn ions), have been investigated. Transmittance spectra in UV and VIS region of some selected glasses have been measured. A correlation between optical properties and UV absorption edge of the transmittance have been done. Using p[sup 31]-NMR spectroscopy the structural changes on short-range level order are studied. A strong influence on the refraction and dispersion values as well as UV-absorption ability of the glasses is established. For p[sup 31] -NMR spectroscopy investigations of crystalline phosphotellurites and related phosphotellurite glasses the TeO[sub 2]-P[sub 2]O[sub 5B]aO ternary system have been chosen. (author).

  10. Optical Measurement Techniques for Rocket Engine Testing and Component Applications: Digital Image Correlation and Dynamic Photogrammetry

    Science.gov (United States)

    Gradl, Paul

    2016-01-01

    NASA Marshall Space Flight Center (MSFC) has been advancing dynamic optical measurement systems, primarily Digital Image Correlation, for extreme environment rocket engine test applications. The Digital Image Correlation (DIC) technology is used to track local and full field deformations, displacement vectors and local and global strain measurements. This technology has been evaluated at MSFC through lab testing to full scale hotfire engine testing of the J-2X Upper Stage engine at Stennis Space Center. It has been shown to provide reliable measurement data and has replaced many traditional measurement techniques for NASA applications. NASA and AMRDEC have recently signed agreements for NASA to train and transition the technology to applications for missile and helicopter testing. This presentation will provide an overview and progression of the technology, various testing applications at NASA MSFC, overview of Army-NASA test collaborations and application lessons learned about Digital Image Correlation.

  11. Thermal Testing and Model Correlation for Advanced Topographic Laser Altimeter Instrument (ATLAS)

    Science.gov (United States)

    Patel, Deepak

    2016-01-01

    The Advanced Topographic Laser Altimeter System (ATLAS) part of the Ice Cloud and Land Elevation Satellite 2 (ICESat-2) is an upcoming Earth Science mission focusing on the effects of climate change. The flight instrument passed all environmental testing at GSFC (Goddard Space Flight Center) and is now ready to be shipped to the spacecraft vendor for integration and testing. This topic covers the analysis leading up to the test setup for ATLAS thermal testing as well as model correlation to flight predictions. Test setup analysis section will include areas where ATLAS could not meet flight like conditions and what were the limitations. Model correlation section will walk through changes that had to be made to the thermal model in order to match test results. The correlated model will then be integrated with spacecraft model for on-orbit predictions.

  12. Long- and short-term trends in vessel conditioning of TFTR [Tokamak Fusion Test Reactor

    International Nuclear Information System (INIS)

    LaMarche, P.H.; Dylla, H.F.; Bell, M.G.

    1986-10-01

    We have investigated trends in the conditioning of the Tokamak Fusion Test Reactor (TFTR) vacuum vessel during the May 1984 to April 1985 run period. The initial conditioning of the vessel, consisting of glow discharge cleaning (GDC) and pulse discharge cleaning (PDC) in concert with a 150 0 C vessel bakeout, is necessary to assure plasma operation after atmospheric venting. A long-term conditioning process, ascribed to limiter conditioning, effectively improves operational conditions during the course of the run. Over several thousand high power plasma discharges, the improvement was documented by using standard parameter (fiducial) plasma discharges. Several techniques demonstrated short-term improvements in vessel conditioning during this time period, including: Cr gettering and programming the plasma position relative to the limiter contact area

  13. Temporal stability of the Francis Scale of Attitude toward Christianity short-form: test-retest data over one week.

    Science.gov (United States)

    Lewis, Christopher Alan; Cruise, Sharon Mary; McGuckin, Conor

    2005-04-01

    This study evaluated the test-retest reliability of the Francis Scale of Attitude toward Christianity short-form. 39 Northern Irish undergraduate students completed the measure on two occasions separated by one week. Stability across the two administrations was high, r = .92, and there was no significant change between Time 1(M = 25.2, SD = 5.4) and Time 2 (M = 25.7, SD = 6.2). These data support the short-term test-retest reliability of the Francis Scale of Attitude toward Christianity short-form.

  14. Current research efforts at JILA to test the equivalence principle at short ranges

    International Nuclear Information System (INIS)

    Faller, J.E.; Niebauer, T.M.; McHugh, M.P.; Van Baak, D.A.

    1988-01-01

    We are presently engaged in three different experiments to search for a possible breakdown of the equivalence principle at short ranges. The first of these experiments, which has been completed, is our so-called Galilean test in which the differential free-fall of two objects of differing composition was measured using laser interferometry. We observed that the differential acceleration of two test bodies was less than 5 parts in 10 billion. This experiment set new limits on a suggested baryon dependent ''Fifth Force'' at ranges longer than 1 km. With a second experiment, we are investigating substance dependent interactions primarily for ranges up to 10 meters using a fluid supported torsion balance; this apparatus has been built and is now undergoing laboratory tests. Finally, a proposal has been made to measure the gravitational signal associated with the changing water level at a large pumped storage facility in Ludington, Michigan. Measuring the gravitational signal above and below the pond will yield the value of the gravitational constant, G, at ranges from 10-100 m. These measurements will serve as an independent check on other geophysical measurements of G

  15. Correlation Between Screening Mammography Interpretive Performance on a Test Set and Performance in Clinical Practice.

    Science.gov (United States)

    Miglioretti, Diana L; Ichikawa, Laura; Smith, Robert A; Buist, Diana S M; Carney, Patricia A; Geller, Berta; Monsees, Barbara; Onega, Tracy; Rosenberg, Robert; Sickles, Edward A; Yankaskas, Bonnie C; Kerlikowske, Karla

    2017-10-01

    Evidence is inconsistent about whether radiologists' interpretive performance on a screening mammography test set reflects their performance in clinical practice. This study aimed to estimate the correlation between test set and clinical performance and determine if the correlation is influenced by cancer prevalence or lesion difficulty in the test set. This institutional review board-approved study randomized 83 radiologists from six Breast Cancer Surveillance Consortium registries to assess one of four test sets of 109 screening mammograms each; 48 radiologists completed a fifth test set of 110 mammograms 2 years later. Test sets differed in number of cancer cases and difficulty of lesion detection. Test set sensitivity and specificity were estimated using woman-level and breast-level recall with cancer status and expert opinion as gold standards. Clinical performance was estimated using women-level recall with cancer status as the gold standard. Spearman rank correlations between test set and clinical performance with 95% confidence intervals (CI) were estimated. For test sets with fewer cancers (N = 15) that were more difficult to detect, correlations were weak to moderate for sensitivity (woman level = 0.46, 95% CI = 0.16, 0.69; breast level = 0.35, 95% CI = 0.03, 0.61) and weak for specificity (0.24, 95% CI = 0.01, 0.45) relative to expert recall. Correlations for test sets with more cancers (N = 30) were close to 0 and not statistically significant. Correlations between screening performance on a test set and performance in clinical practice are not strong. Test set performance more accurately reflects performance in clinical practice if cancer prevalence is low and lesions are challenging to detect. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  16. Simple construct evaluation with latent class analysis: An investigation of Facebook addiction and the development of a short form of the Facebook Addiction Test (F-AT).

    Science.gov (United States)

    Dantlgraber, Michael; Wetzel, Eunike; Schützenberger, Petra; Stieger, Stefan; Reips, Ulf-Dietrich

    2016-09-01

    In psychological research, there is a growing interest in using latent class analysis (LCA) for the investigation of quantitative constructs. The aim of this study is to illustrate how LCA can be applied to gain insights on a construct and to select items during test development. We show the added benefits of LCA beyond factor-analytic methods, namely being able (1) to describe groups of participants that differ in their response patterns, (2) to determine appropriate cutoff values, (3) to evaluate items, and (4) to evaluate the relative importance of correlated factors. As an example, we investigated the construct of Facebook addiction using the Facebook Addiction Test (F-AT), an adapted version of the Internet Addiction Test (I-AT). Applying LCA facilitates the development of new tests and short forms of established tests. We present a short form of the F-AT based on the LCA results and validate the LCA approach and the short F-AT with several external criteria, such as chatting, reading newsfeeds, and posting status updates. Finally, we discuss the benefits of LCA for evaluating quantitative constructs in psychological research.

  17. Numerical thermal mathematical model correlation to thermal balance test using adaptive particle swarm optimization (APSO)

    International Nuclear Information System (INIS)

    Beck, T.; Bieler, A.; Thomas, N.

    2012-01-01

    We present structural and thermal model (STM) tests of the BepiColombo laser altimeter (BELA) receiver baffle with emphasis on the correlation of the data with a thermal mathematical model. The test unit is a part of the thermal and optical protection of the BELA instrument being tested under infrared and solar irradiation at University of Bern. An iterative optimization method known as particle swarm optimization has been adapted to adjust the model parameters, mainly the linear conductivity, in such a way that model and test results match. The thermal model reproduces the thermal tests to an accuracy of 4.2 °C ± 3.2 °C in a temperature range of 200 °C after using only 600 iteration steps of the correlation algorithm. The use of this method brings major benefits to the accuracy of the results as well as to the computational time required for the correlation. - Highlights: ► We present model correlations of the BELA receiver baffle to thermal balance tests. ► Adaptive particle swarm optimization has been adapted for the correlation. ► The method improves the accuracy of the correlation and the computational time.

  18. A study on stress analysis of small punch-creep test and its experimental correlations with uniaxial-creep test

    International Nuclear Information System (INIS)

    Lee, Song In; Baek, Seoung Se; Kwon, Il Hyun; Yu, Hyo Sun

    2002-01-01

    A basic research was performed to ensure the usefulness of Small Punch-creep(SP-creep) test for residual life evaluation of heat resistant components effectively. This paper presents analytical results of initial stress and strain distributions in SP specimen caused by constant loading for SP-creep test and its experimental correlations with uniaxial creep(Ten-creep) test on 9CrlMoVNb steel. It was shown that the initial maximum equivalent stress, σ eq · max from FE analysis was correlated with steady-state equivalent creep strain rate, ε qf-ss , rupture time, t r , activation energy, Q and Larson-Miller parameter, LMP during SP-creep deformation. The simple correlation laws, σ SP - σ TEN , P SP -σ TEN and Q SP -Q TEN adopted to established a quantitative correlation between SP-creep and Ten-creep test data. Especially, the activation energy obtained from SP-creep test is linearly related to that from Ten-creep test at 650 deg. C as follows : Q SP-P =1.37 Q TEN , Q SP-σ =1.53 Q TEN

  19. Correlation with liver scintigram, reticuloendothelial function test, plasma endotoxin level and liver function tests in chronic liver diseases. Multivariate analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ohmoto, Kenji; Yamamoto, Shinichi; Ideguchi, Seiji and others

    1989-02-01

    Liver scintigrams with Tc-99m phytate were reviewed in a total of 64 consecutive patients, comprising 28 with chronic hepatitis and 36 with liver cirrhosis. Reticuloendothelial (RES) function, plasma endotoxin (Et) levels and findings of general liver function tests were used as reference parameters to determine the diagnostic ability of liver scintigraphy. Multivariate analyses revealed that liver scintigrams had a strong correlation with RES function and Et levels in terms of morphology of the liver and hepatic and bone marrow Tc-99m uptake. General liver function tests revealed gamma globulin to be correlated with hepatic uptake and the degree of splenogemaly on liver scintigrams; and ICG levels at 15 min to be correlated with bone marrow and splenic uptake. Accuracy of liver scintigraphy was 73% for chronic hepatitis, which was inferior to general liver function tests (83%). When both modalities were combined, diangostic accuracy increased to 95%. Liver scintigraphy seems to be useful as a complementary approach. (Namekawa, K).

  20. Statistical power analyses using G*Power 3.1: tests for correlation and regression analyses.

    Science.gov (United States)

    Faul, Franz; Erdfelder, Edgar; Buchner, Axel; Lang, Albert-Georg

    2009-11-01

    G*Power is a free power analysis program for a variety of statistical tests. We present extensions and improvements of the version introduced by Faul, Erdfelder, Lang, and Buchner (2007) in the domain of correlation and regression analyses. In the new version, we have added procedures to analyze the power of tests based on (1) single-sample tetrachoric correlations, (2) comparisons of dependent correlations, (3) bivariate linear regression, (4) multiple linear regression based on the random predictor model, (5) logistic regression, and (6) Poisson regression. We describe these new features and provide a brief introduction to their scope and handling.

  1. Effects of an Inquiry-Based Short Intervention on State Test Anxiety in Comparison to Alternative Coping Strategies

    Directory of Open Access Journals (Sweden)

    Ann Krispenz

    2018-02-01

    Full Text Available Background and Objectives: Test anxiety can have undesirable consequences for learning and academic achievement. The control-value theory of achievement emotions assumes that test anxiety is experienced if a student appraises an achievement situation as important (value appraisal, but feels that the situation and its outcome are not fully under his or her control (control appraisal. Accordingly, modification of cognitive appraisals is assumed to reduce test anxiety. One method aiming at the modification of appraisals is inquiry-based stress reduction. In the present study (N = 162, we assessed the effects of an inquiry-based short intervention on test anxiety.Design: Short-term longitudinal, randomized control trial.Methods: Focusing on an individual worry thought, 53 university students received an inquiry-based short intervention. Control participants reflected on their worry thought (n = 55 or were distracted (n = 52. Thought related test anxiety was assessed before, immediately after, and 2 days after the experimental treatment.Results: After the intervention as well as 2 days later, individuals who had received the inquiry-based intervention demonstrated significantly lower test anxiety than participants from the pooled control groups. Further analyses showed that the inquiry-based short intervention was more effective than reflecting on a worry thought but had no advantage over distraction.Conclusions: Our findings provide first experimental evidence for the effectiveness of an inquiry-based short intervention in reducing students’ test anxiety.

  2. Towards automatic recognition of irregular, short-open answers in Fill-in-the-blank tests

    Directory of Open Access Journals (Sweden)

    Sergio A. Rojas

    2014-01-01

    Full Text Available Assessment of student knowledge in Learning Management Systems such as Moodle is mostly conducted using close-ended questions (e.g. multiple-choice whose answers are straightforward to grade without human intervention. FILL-IN-THE-BLANK tests are usually more challenging since they require test-takers to recall concepts and associations not available in the statement of the question itself (no choices or hints are given. Automatic assessment of the latter currently requires the test-taker to give a verbatim answer, that is, free of spelling or typographical mistakes. In this paper, we consider an adapted version of a classical text-matching algorithm that may prevent wrong grading in automatic assessment of FILL-IN-THE-BLANK questions whenever irregular (similar but not exact answers occur due to such types of error. The technique was tested in two scenarios. In the first scenario, misspelled single-word answers to an Internet security questionnaire were correctly recognized within a two letter editing tolerance (achieving 99 % accuracy. The second scenario involved short-open answers to computer programming quizzes (i.e. small blocks of code requiring a structure that conforms to the syntactic rules of the programming language. Twenty-one real-world answers written up by students, taking a computer programming course, were assessed by the method. This assessment addressed the lack of precision in terms of programmer-style artifacts (such as unfamiliar variable or function nomenclature and uses an admissible tolerance of up to 20 % letter-level typos. These scores were satisfactory corroborated by a human expert. Additional findings and potential enhancements to the technique are also discussed.

  3. Pitch control margin at high angle of attack - Quantitative requirements (flight test correlation with simulation predictions)

    Science.gov (United States)

    Lackey, J.; Hadfield, C.

    1992-01-01

    Recent mishaps and incidents on Class IV aircraft have shown a need for establishing quantitative longitudinal high angle of attack (AOA) pitch control margin design guidelines for future aircraft. NASA Langley Research Center has conducted a series of simulation tests to define these design guidelines. Flight test results have confirmed the simulation studies in that pilot rating of high AOA nose-down recoveries were based on the short-term response interval in the forms of pitch acceleration and rate.

  4. The Cross-Correlation and Reshuffling Tests in Discerning Induced Seismicity

    Science.gov (United States)

    Schultz, Ryan; Telesca, Luciano

    2018-05-01

    In recent years, cases of newly emergent induced clusters have increased seismic hazard and risk in locations with social, environmental, and economic consequence. Thus, the need for a quantitative and robust means to discern induced seismicity has become a critical concern. This paper reviews a Matlab-based algorithm designed to quantify the statistical confidence between two time-series datasets. Similar to prior approaches, our method utilizes the cross-correlation to delineate the strength and lag of correlated signals. In addition, use of surrogate reshuffling tests allows for the dynamic testing against statistical confidence intervals of anticipated spurious correlations. We demonstrate the robust nature of our algorithm in a suite of synthetic tests to determine the limits of accurate signal detection in the presence of noise and sub-sampling. Overall, this routine has considerable merit in terms of delineating the strength of correlated signals, one of which includes the discernment of induced seismicity from natural.

  5. Correlations between cerebral glucose metabolism and neuropsychological test performance in nonalcoholic cirrhotics.

    Science.gov (United States)

    Lockwood, Alan H; Weissenborn, Karin; Bokemeyer, Martin; Tietge, U; Burchert, Wolfgang

    2002-03-01

    Many cirrhotics have abnormal neuropsychological test scores. To define the anatomical-physiological basis for encephalopathy in nonalcoholic cirrhotics, we performed resting-state fluorodeoxyglucose positron emission tomographic scans and administered a neuropsychological test battery to 18 patients and 10 controls. Statistical parametric mapping correlated changes in regional glucose metabolism with performance on the individual tests and a composite battery score. In patients without overt encephalopathy, poor performance correlated with reductions in metabolism in the anterior cingulate. In all patients, poor performance on the battery was positively correlated (p glucose metabolism in bifrontal and biparietal regions of the cerebral cortex and negatively correlated with metabolism in hippocampal, lingual, and fusiform gyri and the posterior putamen. Similar patterns of abnormal metabolism were found when comparing the patients to 10 controls. Metabolic abnormalities in the anterior attention system and association cortices mediating executive and integrative function form the pathophysiological basis for mild hepatic encephalopathy.

  6. Testing gravitational parity violation with coincident gravitational waves and short gamma-ray bursts

    International Nuclear Information System (INIS)

    Yunes, Nicolas; O'Shaughnessy, Richard; Owen, Benjamin J.; Alexander, Stephon

    2010-01-01

    Gravitational parity violation is a possibility motivated by particle physics, string theory, and loop quantum gravity. One effect of it is amplitude birefringence of gravitational waves, whereby left and right circularly polarized waves propagate at the same speed but with different amplitude evolution. Here we propose a test of this effect through coincident observations of gravitational waves and short gamma-ray bursts from binary mergers involving neutron stars. Such gravitational waves are highly left or right circularly polarized due to the geometry of the merger. Using localization information from the gamma-ray burst, ground-based gravitational wave detectors can measure the distance to the source with reasonable accuracy. An electromagnetic determination of the redshift from an afterglow or host galaxy yields an independent measure of this distance. Gravitational parity violation would manifest itself as a discrepancy between these two distance measurements. We exemplify such a test by considering one specific effective theory that leads to such gravitational parity violation, Chern-Simons gravity. We show that the advanced LIGO-Virgo network and all-sky gamma-ray telescopes can be sensitive to the propagating sector of Chern-Simons gravitational parity violation to a level roughly 2 orders of magnitude better than current stationary constraints from the LAGEOS satellites.

  7. LISA Pathfinder test-mass charging during galactic cosmic-ray flux short-term variations

    Science.gov (United States)

    Grimani, C.; Fabi, M.; Lobo, A.; Mateos, I.; Telloni, D.

    2015-02-01

    Metal free-floating test masses aboard the future interferometers devoted to gravitational wave detection in space are charged by galactic and solar cosmic rays with energies \\gt 100 MeV/n. This process represents one of the main sources of noise in the lowest frequency band (\\lt 10-3 Hz) of these experiments. We study here the charging of the LISA Pathfinder (LISA-PF) gold-platinum test masses due to galactic cosmic-ray (GCR) protons and helium nuclei with the Fluka Monte Carlo toolkit. Projections of the energy spectra of GCRs during the LISA-PF operations in 2015 are considered. This work was carried out on the basis of the solar activity level and solar polarity epoch expected for LISA-PF. The effects of GCR short-term variations are evaluated here for the first time. Classical Forbush decreases, GCR variations induced by the Sun rotation, and fluctuations in the LISA-PF frequency bandwidth are discussed.

  8. The Cherenkov correlated timing detector: beam test results from quartz and acrylic bars

    International Nuclear Information System (INIS)

    Kichimi, H.; Sugaya, Y.; Yamaguchi, H.; Yoshimura, Y.; Kanda, S.; Olsen, S.; Ueno, K.; Varner, G.; Bergfeld, T.; Bialek, J.; Lorenc, J.; Palmer, M.; Rudnick, G.; Selen, M.; Auran, T.; Boyer, V.; Honscheid, K.; Tamura, N.; Yoshimura, K.; Lu, C.; Marlow, D.; Mindas, C.; Prebys, E.; Asai, M.; Kimura, A.; Hayashi, S.

    1996-01-01

    Several prototypes of a Cherenkov correlated timing (CCT) detector have been tested at the KEK-PS test beam line. We describe the results for Cherenkov light yields and timing characteristics from quartz and acrylic bar prototypes. A Cherenkov angle resolution is found to be 15 mrad at a propagation distance of 100 cm with a 2 cm thick quartz bar prototype. (orig.)

  9. Inference and testing on the boundary in extended constant conditional correlation GARCH models

    DEFF Research Database (Denmark)

    Pedersen, Rasmus Søndergaard

    2017-01-01

    We consider inference and testing in extended constant conditional correlation GARCH models in the case where the true parameter vector is a boundary point of the parameter space. This is of particular importance when testing for volatility spillovers in the model. The large-sample properties...

  10. Correlation among High School Senior Students' Test Anxiety, Academic Performance and Points of University Entrance Exam

    Science.gov (United States)

    Karatas, Hakan; Alci, Bulent; Aydin, Hasan

    2013-01-01

    Test anxiety seems like a benign problem to some people, but it can be potentially serious when it leads to high levels of distress and academic failure. The aim of this study is to define the correlation among high school senior students' test anxiety, academic performance (GPA) and points of university entrance exam (UEE). The study group of…

  11. On the possibility of extending the tests of quantum mechanical correlations

    International Nuclear Information System (INIS)

    Bergia, S.

    1984-01-01

    Experimental tests of quantum mechanical correlations in connection with Bell's inequality have generally considered decays in sub-systems characterized by two-valued observables. The author analyses the possibility of extending these tests to a much wider class of cases. (Auth.)

  12. Sample Size Calculation for Estimating or Testing a Nonzero Squared Multiple Correlation Coefficient

    Science.gov (United States)

    Krishnamoorthy, K.; Xia, Yanping

    2008-01-01

    The problems of hypothesis testing and interval estimation of the squared multiple correlation coefficient of a multivariate normal distribution are considered. It is shown that available one-sided tests are uniformly most powerful, and the one-sided confidence intervals are uniformly most accurate. An exact method of calculating sample size to…

  13. Correlation of index tests with smectite content determined with XRD in bentonite and smectite rich clays

    International Nuclear Information System (INIS)

    Kumpulainen, Sirpa; Kiviranta, Leena; Korkeakoski, Petri

    2012-01-01

    Document available in extended abstract form only. Various index tests are used by bentonite producers and users to assess the amount of swelling minerals in bentonites and smectite rich clays. Index tests are meant to provide relative fast and inexpensive way of testing the amount of swelling minerals, and their performance should not require sophisticated equipment. Such index tests are e.g. methylene blue absorption test, liquid limit and swelling index test (free swelling). In order to select appropriate index test to control the quality of buffer and backfill materials to be used in nuclear waste end disposal in Finland, results from various index tests were correlated with the smectite content determined with XRD and Rietveld refinement. Tests evaluated were: water absorption capacity (WAC) based on DIN 18132, swelling index (SI) based on ASTM D 5890-06, cation exchange capacity (CEC) based on Cu(II)-trien adsorption by Meier and Kahr (1999) and Ammann et al. (2005), liquid limit (LL) based on CEN ISO/TS 17892- 12:2004, methylene blue absorption (MB) based on SFS-EN 933-9, and specific surface area based on absorption of ethylene glycol monoethyl ether (EGME) described by Cerato and Lutenegger (2002). The number of samples tested was 6-25 (exact number of samples was dependent on the test method), and included natural Na-bentonites, natural Ca-bentonites, sodium activated Ca-bentonites and smectite rich clays from Wyoming/USA, Milos/Greece, Gujarat/India and Friedland/Germany. Smectite content in samples was determined after Kiviranta and Kumpulainen (2011) by x-ray diffraction (XRD), optical microscopy, chemical analyses, and full-pattern fitting with the Rietveld method using Siroquant software. Exchangeable cation composition was determined after Belyayeva (1967) and Jackson (1975). In order to achieve correlation of index test results with smectite content, water absorption capacity, liquid limit, and swelling index methods required additional information

  14. Influence of test tube material on subcooled flow boiling critical heat flux in short vertical tube

    International Nuclear Information System (INIS)

    Hata, Koichi; Shiotsu, Masahiro; Noda, Nobuaki

    2007-01-01

    The steady state subcooled flow boiling critical heat flux (CHF) for the flow velocities (u=4.0 to 13.3 m/s), the inlet subcoolings (ΔT sub,in =48.6 to 154.7 K), the inlet pressure (P in =735.2 to 969.0 kPa) and the increasing heat input (Q 0 exp(t/τ), τ=10, 20 and 33.3 s) are systematically measured with the experimental water loop. The 304 Stainless Steel (SUS304) test tube of inner diameter (d=6 mm), heated length (L=66 mm) and L/d=11 with the inner surface of rough finished (Surface roughness, Ra=3.18 μm), the Cupro Nickel (Cu-Ni 30%) test tube of d=6 mm, L=60 mm and L/d=10 with Ra=0.18 μm and the Platinum (Pt) test tubes of d=3 and 6 mm, L=66.5 and 69.6 mm, and L/d=22.2 and 11.6 respectively with Ra=0.45 μm are used in this work. The CHF data for the SUS304, Cu-Ni 30% and Pt test tubes were compared with SUS304 ones for the wide ranges of d and L/d previously obtained and the values calculated by the authors' published steady state CHF correlations against outlet and inlet subcoolings. The influence of the test tube material on CHF is investigated into details and the dominant mechanism of subcooled flow boiling critical heat flux is discussed. (author)

  15. Influence of Test Tube Material on Subcooled Flow Boiling Critical Heat Flux in Short Vertical Tube

    International Nuclear Information System (INIS)

    Koichi Hata; Masahiro Shiotsu; Nobuaki Noda

    2006-01-01

    The steady state subcooled flow boiling critical heat flux (CHF) for the flow velocities (u = 4.0 to 13.3 m/s), the inlet subcooling (ΔT sub,in = 48.6 to 154.7 K), the inlet pressure (P in = 735.2 to 969.0 kPa) and the increasing heat input (Q 0 exp(t/t), t = 10, 20 and 33.3 s) are systematically measured with the experimental water loop. The 304 Stainless Steel (SUS304) test tubes of inner diameters (d = 6 mm), heated lengths (L = 66 mm) and L/d = 11 with the inner surface of rough finished (Surface roughness, R a = 3.18 μm), the Cupro Nickel (Cu-Ni 30%) test tubes of d = 6 mm, L = 60 mm and L/d = 10 with R a = 0.18 μm and the Platinum (Pt) test tubes of d = 3 and 6 mm, L = 66.5 and 69.6 mm, and L/d 22.2 and 11.6 respectively with R a = 0.45 μm are used in this work. The CHF data for the SUS304, Cu-Ni 30% and Pt test tubes were compared with SUS304 ones for the wide ranges of d and L/d previously obtained and the values calculated by the authors' published steady state CHF correlations against outlet and inlet subcooling. The influence of the test tube material on CHF is investigated into details and the dominant mechanism of subcooled flow boiling critical heat flux is discussed. (authors)

  16. Alternative short tests for inspection and maintenance of in-use cars with respect to their emissions performance

    NARCIS (Netherlands)

    Samaras, Z.; Zachariadis, T.; Joumard, R.; Vernet, I.; Hassel, D.; Weber, F.-J.; Rijkeboer, R.C.

    1998-01-01

    This paper presents the first results of a project aimed at evaluation of a number of short tests that can be alternatively used for Inspection and Maintenance of in-use cars emissions performance. For this purpose, a large number of in-use cars from four European countries was tested according to a

  17. A comparison of discriminant logistic regression and Item Response Theory Likelihood-Ratio Tests for Differential Item Functioning (IRTLRDIF) in polytomous short tests.

    Science.gov (United States)

    Hidalgo, María D; López-Martínez, María D; Gómez-Benito, Juana; Guilera, Georgina

    2016-01-01

    Short scales are typically used in the social, behavioural and health sciences. This is relevant since test length can influence whether items showing DIF are correctly flagged. This paper compares the relative effectiveness of discriminant logistic regression (DLR) and IRTLRDIF for detecting DIF in polytomous short tests. A simulation study was designed. Test length, sample size, DIF amount and item response categories number were manipulated. Type I error and power were evaluated. IRTLRDIF and DLR yielded Type I error rates close to nominal level in no-DIF conditions. Under DIF conditions, Type I error rates were affected by test length DIF amount, degree of test contamination, sample size and number of item response categories. DLR showed a higher Type I error rate than did IRTLRDIF. Power rates were affected by DIF amount and sample size, but not by test length. DLR achieved higher power rates than did IRTLRDIF in very short tests, although the high Type I error rate involved means that this result cannot be taken into account. Test length had an important impact on the Type I error rate. IRTLRDIF and DLR showed a low power rate in short tests and with small sample sizes.

  18. Comparison of short-range rapidity correlations in anti pp and pp interactions at √S = 53 GeV

    International Nuclear Information System (INIS)

    Breakstone, A.; Crawley, H.B.; Firestone, A.; Gorbics, M.; Lamsa, J.W.; Meyer, W.T.

    1982-01-01

    Measurements are presented of two-particle rapidity correlations in anti pp and pp at √S = 53 GeV. The data were recorded at the CERN-ISR using the Split Field Magnet spectrometer with a minimum bias trigger. Short range correlations in normal inelastic events with measured charged multiplicities nsub(ch) >= 4 are observed for pairs of charged particles in all charge combinations. Within the experimental errors no differences are observed between the analogous correlations in pp and anti pp interactions. (orig.)

  19. Timescale Correlation between Marine Atmospheric Exposure and Accelerated Corrosion Testing - Part 2

    Science.gov (United States)

    Montgomery, Eliza L.; Calle, Luz Marina; Curran, Jerome C.; Kolody, Mark R.

    2012-01-01

    Evaluation of metals to predict service life of metal-based structures in corrosive environments has long relied on atmospheric exposure test sites. Traditional accelerated corrosion testing relies on mimicking the exposure conditions, often incorporating salt spray and ultraviolet (UV) radiation, and exposing the metal to continuous or cyclic conditions similar to those of the corrosive environment. Their reliability to correlate to atmospheric exposure test results is often a concern when determining the timescale to which the accelerated tests can be related. Accelerated corrosion testing has yet to be universally accepted as a useful tool in predicting the long-term service life of a metal, despite its ability to rapidly induce corrosion. Although visual and mass loss methods of evaluating corrosion are the standard, and their use is crucial, a method that correlates timescales from accelerated testing to atmospheric exposure would be very valuable. This paper presents work that began with the characterization of the atmospheric environment at the Kennedy Space Center (KSC) Beachside Corrosion Test Site. The chemical changes that occur on low carbon steel, during atmospheric and accelerated corrosion conditions, were investigated using surface chemistry analytical methods. The corrosion rates and behaviors of panels subjected to long-term and accelerated corrosion conditions, involving neutral salt fog and alternating seawater spray, were compared to identify possible timescale correlations between accelerated and long-term corrosion performance. The results, as well as preliminary findings on the correlation investigation, are presented.

  20. CORRELATION BETWEEN SEED TESTS AND FIELD EMERGENCE OF TWO MAIZE HYBRIDS (SC704 AND SC500)

    OpenAIRE

    A.A. ALILOO; B. SHOKATI

    2011-01-01

    Early emergence and stand establishment of maize (Zea mays L.) are considered to be the most important yield-contributing factors. The influence of seed vigor on these factors is vital. Therefore, five laboratory tests and field experiment were conducted on basis of a randomized complete block design (RCBD) with five replications in 2011, to evaluate the correlation among the seed vigor tests and field emergence of two maize hybrids (SC704 and SC500). In laboratory tests, differences between ...

  1. Five-Kilometers Time Trial: Preliminary Validation of a Short Test for Cycling Performance Evaluation.

    Science.gov (United States)

    Dantas, Jose Luiz; Pereira, Gleber; Nakamura, Fabio Yuzo

    2015-09-01

    The five-kilometer time trial (TT5km) has been used to assess aerobic endurance performance without further investigation of its validity. This study aimed to perform a preliminary validation of the TT5km to rank well-trained cyclists based on aerobic endurance fitness and assess changes of the aerobic endurance performance. After the incremental test, 20 cyclists (age = 31.3 ± 7.9 years; body mass index = 22.7 ± 1.5 kg/m(2); maximal aerobic power = 360.5 ± 49.5 W) performed the TT5km twice, collecting performance (time to complete, absolute and relative power output, average speed) and physiological responses (heart rate and electromyography activity). The validation criteria were pacing strategy, absolute and relative reliability, validity, and sensitivity. Sensitivity index was obtained from the ratio between the smallest worthwhile change and typical error. The TT5km showed high absolute (coefficient of variation 0.95) reliability of performance variables, whereas it presented low reliability of physiological responses. The TT5km performance variables were highly correlated with the aerobic endurance indices obtained from incremental test (r > 0.70). These variables showed adequate sensitivity index (> 1). TT5km is a valid test to rank the aerobic endurance fitness of well-trained cyclists and to differentiate changes on aerobic endurance performance. Coaches can detect performance changes through either absolute (± 17.7 W) or relative power output (± 0.3 W.kg(-1)), the time to complete the test (± 13.4 s) and the average speed (± 1.0 km.h(-1)). Furthermore, TT5km performance can also be used to rank the athletes according to their aerobic endurance fitness.

  2. The Correlation between Subjective and Objective Visual Function Test in Optic Neuropathy Patients

    Directory of Open Access Journals (Sweden)

    Ungsoo Kim

    2012-10-01

    Full Text Available Purpose: To investigate the correlation between visual acuity and quantitative measurements of visual evoked potentials (VEP, optical coherence tomography (OCT, and visual field test (VF in optic neuropathy patients. Methods: We evaluated 28 patients with optic neuropathy. Patients who had pale disc, visual acuity of less than 0.5 and abnormal visual field defect were included. At the first visit, we performed visual acuity and VF as subjective methods and OCT and VEP as objective methods. In the spectral domain OCT, rim volume, average and temporal quadrant retinal nerve fiber layer (RNFL thickness were measured. And pattern VEP (N75, P100, N135 latency, and P100 amplitude and Humphrey 24-2 visual field test (mean deviation and pattern standard deviation were obtained. Using Spearman's correlation coefficient, the correlation between visual acuity and various techniques were assessed. Results: Visual acuity was most correlated with the mean deviation of Humphrey perimetry.

  3. Biologic variability and correlation of platelet function testing in healthy dogs.

    Science.gov (United States)

    Blois, Shauna L; Lang, Sean T; Wood, R Darren; Monteith, Gabrielle

    2015-12-01

    Platelet function tests are influenced by biologic variability, including inter-individual (CVG ) and intra-individual (CVI ), as well as analytic (CVA ) variability. Variability in canine platelet function testing is unknown, but if excessive, would make it difficult to interpret serial results. Additionally, the correlation between platelet function tests is poor in people, but not well described in dogs. The aims were to: (1) identify the effect of variation in preanalytic factors (venipuncture, elapsed time until analysis) on platelet function tests; (2) calculate analytic and biologic variability of adenosine diphosphate (ADP) and arachidonic acid (AA)-induced thromboelastograph platelet mapping (TEG-PM), ADP-, AA-, and collagen-induced whole blood platelet aggregometry (WBA), and collagen/ADP and collagen/epinephrine platelet function analysis (PFA-CADP, PFA-CEPI); and (3) determine the correlation between these variables. In this prospective observational trial, platelet function was measured once every 7 days, for 4 consecutive weeks, in 9 healthy dogs. In addition, CBC, TEG-PM, WBA, and PFA were performed. Overall coefficients of variability ranged from 13.3% to 87.8% for the platelet function tests. Biologic variability was highest for AA-induced maximum amplitude generated during TEG-PM (MAAA; CVG = 95.3%, CVI = 60.8%). Use of population-based reference intervals (RI) was determined appropriate only for PFA-CADP (index of individuality = 10.7). There was poor correlation between most platelet function tests. Use of population-based RI appears inappropriate for most platelet function tests, and tests poorly correlate with one another. Future studies on biologic variability and correlation of platelet function tests should be performed in dogs with platelet dysfunction and those treated with antiplatelet therapy. © 2015 American Society for Veterinary Clinical Pathology.

  4. Correlation between the median particle size of chewed frankfurter sausage and almonds during masticatory performance test.

    Science.gov (United States)

    Sumonsiri, P; Thongudomporn, U; Paphangkorakit, J

    2018-04-27

    The correlation between chewing and gastric function is best reflected when the same food type is used during both tests. We proposed frankfurter sausage as test food for masticatory performance as it can also be used in gastric emptying test. The suitability of frankfurter sausage to determine masticatory performance, however, has never been examined. To examine the correlations between the median particle size of frankfurter sausage and almonds (as standard test food) after different numbers of chewing cycles. Twenty-seven subjects performed masticatory performance tests by chewing 2 types of test foods, that is, a piece of almond or 5-g frankfurter sausage cubes placed in a sealed latex bag, for 5 and 15 chewing cycles. For each individual, right and left sides were tested separately. Chewed samples obtained from both sides were pooled. Median particle sizes were determined using a multiple sieving method. Spearman's rank correlation was used to examine any correlation between median particle sizes of the 2 test foods after 5 and 15 cycles. Median particle sizes after 5 and 15 cycles were 2.04 ± 0.87 and 0.95 ± 0.58 mm for almonds and 4.16 ± 0.19 and 3.73 ± 0.25 mm for frankfurter sausage, respectively. Significant correlations were observed between the median particle size of chewed frankfurter sausage after 15 cycles and that of chewed almonds after 5 and 15 cycles (r = .76, P < .01 and r = .52, P = .01, respectively). Frankfurter sausage chewed for 15 cycles may be suitable for the determination of masticatory performance in conjunction with gastric emptying test. © 2018 John Wiley & Sons Ltd.

  5. Development of a short sample test facility for evaluating superconducting wires

    International Nuclear Information System (INIS)

    Singh, M.R.; Kulkarni, D.G.; Sahni, V.C.; Ravikumar, G.; Patel, K.L.

    2002-01-01

    In this paper we describe a short sample test facility we have set up at Bhabha Atomic Research Centre (BARC). This facility has been used to measure critical currents of NbTi/Cu composite superconducting wires by recording V versus I data at 4.2 K. It offers sample current as large as 1500 A and a transverse magnetic field up to 7.4 T. A power law, V ∼I n( H) is fitted to the resistive transition region to estimate the exponent n, which is a measure of the uniformity of superconducting filaments in composite wires. It is observed that inadequate thermal stabilization of sample wire results in thermal runaway, which limits the V-I data to∼ 2μ V . This in turn affects the reliability of estimated filament uniformity. To mitigate this problem, we have used a sample holder made of OFHC-Cu which enhances thermal stabilization of the sample. With this sample holder, the results of measurements carried out on wires developed by the Atomic Fuel Division, BARC show a high filament uniformity (n ∼ 58). (author)

  6. Performance Tests of a Short Faraday Cup Designed for HIE-ISOLDE

    CERN Document Server

    Cantero, E; Bravin, E; Fraser, M; Lanaia, D; Sosa, A; Voulot, D

    2013-01-01

    The On-Line Isotope Mass Separator (ISOLDE) facility at CERN is being upgraded in order to deliver higher energy and intensity radioactive beams. The final setup will consist in replacing the energy variable part of the normal conducting REX post-accelerator with superconducting cavities. In order to preserve the beam emittance, the drift space between the cryomodules housing these cavities has been kept to a minimum. As a consequence, the longitudinal space available for beam diagnostics is severely limited in the inter-cryomodule regions. A Faraday cup (FC) will be installed to measure beam currents, and due to the tight spatial constraints, its length is much smaller than usual. This poses a great challenge when trying to avoid the escape of ion-induced secondary electrons, which would falsify the current measurement. Two prototypes of such a short FC have therefore been tested at REX-ISOLDE using several beam intensities and energies, with the aim of determining its accuracy. In this paper the experimenta...

  7. Determination of the source of androgen excess in functionally atypical polycystic ovary syndrome by a short dexamethasone androgen-suppression test and a low-dose ACTH test.

    Science.gov (United States)

    Rosenfield, Robert L; Mortensen, Monica; Wroblewski, Kristen; Littlejohn, Elizabeth; Ehrmann, David A

    2011-11-01

    Polycystic ovary syndrome (PCOS) patients typically have 17-hydroxyprogesterone (17OHP) hyperresponsiveness to GnRH agonist (GnRHa) (PCOS-T). The objective of this study was to determine the source of androgen excess in the one-third of PCOS patients who atypically lack this type of ovarian dysfunction (PCOS-A). Aged-matched PCOS-T (n= 40), PCOS-A (n= 20) and controls (n= 39) were studied prospectively in a General Clinical Research Center. Short (4 h) and long (4-7 day) dexamethasone androgen-suppression tests (SDAST and LDAST, respectively) were compared in subsets of subjects. Responses to SDAST and low-dose adrenocorticotropic hormone (ACTH) were then evaluated in all. Testosterone post-SDAST correlated significantly with testosterone post-LDAST and 17OHP post-GnRHa (r = 0.671-0.672), indicating that all detect related aspects of ovarian dysfunction. An elevated dehydroepiandrosterone peak in response to ACTH, which defined functional adrenal hyperandrogenism, was similarly prevalent in PCOS-T (27.5%) and PCOS-A (30%) and correlated significantly with baseline dehydroepiandrosterone sulfate (DHEAS) (r = 0.708). Functional ovarian hyperandrogenism was detected by subnormal testosterone suppression by SDAST in most (92.5%) PCOS-T, but significantly fewer PCOS-A (60%, PPCOS-A, but present in 30% of PCOS-T (P PCOS-A cases with normal testosterone suppression in response to SDAST (5/8) lacked evidence of adrenal hyperandrogenism and were obese. Functional ovarian hyperandrogenism was not demonstrable by SDAST in 40% of PCOS-A. Most of these cases had no evidence of adrenal hyperandrogenism. Obesity may account for most hyperandrogenemic anovulation that lacks a glandular source of excess androgen, and the SDAST seems useful in making this distinction.

  8. Ultra-high accuracy optical testing: creating diffraction-limited short-wavelength optical systems

    International Nuclear Information System (INIS)

    Goldberg, Kenneth A.; Naulleau, Patrick P.; Rekawa, Senajith B.; Denham, Paul E.; Liddle, J. Alexander; Gullikson, Eric M.; Jackson, KeithH.; Anderson, Erik H.; Taylor, John S.; Sommargren, Gary E.; Chapman, Henry N.; Phillion, Donald W.; Johnson, Michael; Barty, Anton; Soufli, Regina; Spiller, Eberhard A.; Walton, Christopher C.; Bajt, Sasa

    2005-01-01

    Since 1993, research in the fabrication of extreme ultraviolet (EUV) optical imaging systems, conducted at Lawrence Berkeley National Laboratory (LBNL) and Lawrence Livermore National Laboratory (LLNL), has produced the highest resolution optical systems ever made. We have pioneered the development of ultra-high-accuracy optical testing and alignment methods, working at extreme ultraviolet wavelengths, and pushing wavefront-measuring interferometry into the 2-20-nm wavelength range (60-600 eV). These coherent measurement techniques, including lateral shearing interferometry and phase-shifting point-diffraction interferometry (PS/PDI) have achieved RMS wavefront measurement accuracies of 0.5-1-(angstrom) and better for primary aberration terms, enabling the creation of diffraction-limited EUV optics. The measurement accuracy is established using careful null-testing procedures, and has been verified repeatedly through high-resolution imaging. We believe these methods are broadly applicable to the advancement of short-wavelength optical systems including space telescopes, microscope objectives, projection lenses, synchrotron beamline optics, diffractive and holographic optics, and more. Measurements have been performed on a tunable undulator beamline at LBNL's Advanced Light Source (ALS), optimized for high coherent flux; although many of these techniques should be adaptable to alternative ultraviolet, EUV, and soft x-ray light sources. To date, we have measured nine prototype all-reflective EUV optical systems with NA values between 0.08 and 0.30 (f/6.25 to f/1.67). These projection-imaging lenses were created for the semiconductor industry's advanced research in EUV photolithography, a technology slated for introduction in 2009-13. This paper reviews the methods used and our program's accomplishments to date

  9. On the correlation between minimum thickness and central deflection during small punch test

    International Nuclear Information System (INIS)

    Kumar, Pradeep; Chattopadhyay, J.; Dutta, B.K.

    2016-01-01

    Present paper deals with a detailed study on the correlation between minimum thickness (t/t_0) and central deflection (δ/t_0). Such data are obtained during the deformation of a small punch test of miniaturized specimen. Finite element studies have been carried out to investigate the effect of various parameters which are expected to influence this correlation. The parameters under consideration are material hardening, material yield stress, coefficient of friction and initial thickness of the specimen. It is shown that the correlation remains unaffected with respect to change in material parameters. Similarly, the coefficient of friction beyond 0.2 also does not affect the correlation. However, change in thickness has significant effect on the correlation. A modification has been suggested in the existing correlation to consider the influence of thickness change. The modified correlation is then used to calculate fracture toughness using the experimental results quoted in the literature. It is shown that the modified correlation improves the fracture toughness prediction considerably.

  10. Psychometric test of the Team Climate Inventory-short version investigated in Dutch quality improvement teams

    Directory of Open Access Journals (Sweden)

    Nieboer Anna P

    2009-07-01

    Full Text Available Abstract Background Although some studies have used the Team Climate Inventory within teams working in health care settings, none of these included quality improvement teams. The aim of our study is to investigate the psychometric properties of the 14-item version of the Team Climate Inventory in healthcare quality improvement teams participating in a Dutch quality collaborative. Methods This study included quality improvement teams participating in the Care for Better improvement program for home care, care for the handicapped and the elderly in the Netherlands between 2006 and 2008. As part of a larger evaluation study 270 written questionnaires from team members were collected at baseline and 139 questionnaires at end measurement. Confirmatory factor analyses, reliability, Pearson correlations and paired samples t-tests were conducted to investigate construct validity, reliability, predictive validity and temporal stability. Results Confirmatory factor analyses revealed the expected four-factor structure and good fit indices. For the four subscales – vision, participative safety, task orientation and support for innovation – acceptable Cronbach's alpha coefficients and high inter-item correlations were found. The four subscales all proved significant predictors of perceived team effectiveness, with participatory safety being the best predictor. As expected the four subscales were found to be stable over time; i.e. without significant changes between baseline and end measurement. Conclusion The psychometric properties of the Dutch version of the TCI-14 are satisfactory. Together these results show that the TCI-14 is a useful instrument to assess to what extent aspects of team climate influence perceived team effectiveness of quality improvement teams.

  11. Psychometric test of the Team Climate Inventory-short version investigated in Dutch quality improvement teams.

    Science.gov (United States)

    Strating, Mathilde M H; Nieboer, Anna P

    2009-07-24

    Although some studies have used the Team Climate Inventory within teams working in health care settings, none of these included quality improvement teams. The aim of our study is to investigate the psychometric properties of the 14-item version of the Team Climate Inventory in healthcare quality improvement teams participating in a Dutch quality collaborative. This study included quality improvement teams participating in the Care for Better improvement program for home care, care for the handicapped and the elderly in the Netherlands between 2006 and 2008. As part of a larger evaluation study 270 written questionnaires from team members were collected at baseline and 139 questionnaires at end measurement. Confirmatory factor analyses, reliability, Pearson correlations and paired samples t-tests were conducted to investigate construct validity, reliability, predictive validity and temporal stability. Confirmatory factor analyses revealed the expected four-factor structure and good fit indices. For the four subscales--vision, participative safety, task orientation and support for innovation--acceptable Cronbach's alpha coefficients and high inter-item correlations were found. The four subscales all proved significant predictors of perceived team effectiveness, with participatory safety being the best predictor. As expected the four subscales were found to be stable over time; i.e. without significant changes between baseline and end measurement. The psychometric properties of the Dutch version of the TCI-14 are satisfactory. Together these results show that the TCI-14 is a useful instrument to assess to what extent aspects of team climate influence perceived team effectiveness of quality improvement teams.

  12. Correlates of STI testing among vocational school students in the Netherlands

    Directory of Open Access Journals (Sweden)

    Mackenbach Johan P

    2010-11-01

    Full Text Available Abstract Background Adolescents are at risk for acquiring sexually transmitted infections (STIs. However, test rates among adolescents in the Netherlands are low and effective interventions that encourage STI testing are scarce. Adolescents who attend vocational schools are particularly at risk for STI. The purpose of this study is to inform the development of motivational health promotion messages by identifying the psychosocial correlates of STI testing intention among adolescents with sexual experience attending vocational schools. Methods This study was conducted among 501 students attending vocational schools aged 16 to 25 years (mean 18.3 years ± 2.1. Data were collected via a web-based survey exploring relationships, sexual behavior and STI testing behavior. Items measuring the psychosocial correlates of testing were derived from Fishbein's Integrative Model. Data were subjected to multiple regression analyses. Results Students reported substantial sexual risk behavior and low intention to participate in STI testing. The model explained 39% of intention to engage in STI testing. The most important predictor was attitude. Perceived norms, perceived susceptibility and test site characteristics were also significant predictors. Conclusions The present study provides important and relevant empirical input for the development of health promotion interventions aimed at motivating adolescents at vocational schools in the Netherlands to participate in STI testing. Health promotion interventions developed for this group should aim to change attitudes, address social norms and increase personal risk perception for STI while also promoting the accessibility of testing facilities.

  13. Characterization of new eye drops with choline salicylate and assessment of their irritancy by in vitro short time exposure tests.

    Science.gov (United States)

    Wroblewska, Katarzyna; Kucinska, Małgorzata; Murias, Marek; Lulek, Janina

    2015-09-01

    The aim of our study was to examine the irritation potential of new eye drops containing 2% choline salicylate (CS) as an active pharmaceutical ingredient (API) and various polymers increasing eye drop viscosity (hydroxyethylcellulose, hydroxypropyl methylcellulose, methylcellulose, polyvinyl alcohol, polyvinylpyrrolidone). The standard method for assessing the potential of irritating substances has been the Draize rabbit eye test. However the European Centre for Validation of Alternative Methods and the Coordinating Committee for Validation of Alternative Methods recommend, short time exposure (STE) in vitro tests as an alternative method for assessing eye irritation. The eye irritation potential was determined using cytotoxicity test methods for rabbit corneal cell line (SIRC) after 5 min exposure. The viability of cells was determined using two cytotoxicity assays: MTT and Neutral Red Uptake. According to the irritation rankings for the short time exposure test, all tested eye drops are classified as non-irritating (cell viability >70%).

  14. Lack of Correlation between Severity of Clinical Symptoms, Skin Test Reactivity, and Radioallergosorbent Test Results in Venom-Allergic Patients

    Directory of Open Access Journals (Sweden)

    Warrington RJ

    2006-06-01

    Full Text Available Abstract Purpose To retrospectively examine the relation between skin test reactivity, venom-specific immunoglobulin E (IgE antibody levels, and severity of clinical reaction in patients with insect venom allergy. Method Thirty-six patients (including 15 females who presented with a history of allergic reactions to insect stings were assessed. The mean age at the time of the reactions was 33.4 ± 15.1 years (range, 4-76 years, and patients were evaluated 43.6 ± 90 months (range, 1-300 months after the reactions. Clinical reactions were scored according to severity, from 1 (cutaneous manifestations only to 3 (anaphylaxis with shock. These scores were compared to scores for skin test reactivity (0 to 5, indicating the log increase in sensitivity from 1 μg/mL to 0.0001 μg/mL and radioallergosorbent test (RAST levels (0 to 4, indicating venom-specific IgE levels, from undetectable to >17.5 kilounits of antigen per litre [kUA/L]. Results No correlation was found between skin test reactivity (Spearman's coefficient = 0.15, p = .377 or RAST level (Spearman's coefficient = 0.32, p = .061 and the severity of reaction. Skin test and RAST scores both differed significantly from clinical severity (p p = .042. There was no correlation between skin test reactivity and time since reaction (Spearman's coefficient = 0.18, p = .294 nor between RAST and time since reaction (r = 0.1353, p = .438. Elimination of patients tested more than 12 months after their reaction still produced no correlation between skin test reactivity (p = .681 or RAST score (p = .183 and the severity of the clinical reaction. Conclusion In venom-allergic patients (in contrast to reported findings in cases of inhalant IgE-mediated allergy, there appears to be no significant correlation between the degree of skin test reactivity or levels of venom-specific IgE (determined by RAST and the severity of the clinical reaction.

  15. Computational Bench Testing to Evaluate the Short-Term Mechanical Performance of a Polymeric Stent.

    Science.gov (United States)

    Bobel, A C; Petisco, S; Sarasua, J R; Wang, W; McHugh, P E

    2015-12-01

    Over the last decade, there has been a significant volume of research focussed on the utilization of biodegradable polymers such as poly-L-lactide-acid (PLLA) for applications associated with cardiovascular disease. More specifically, there has been an emphasis on upgrading current clinical shortfalls experienced with conventional bare metal stents and drug eluting stents. One such approach, the adaption of fully formed polymeric stents has led to a small number of products being commercialized. Unfortunately, these products are still in their market infancy, meaning there is a clear non-occurrence of long term data which can support their mechanical performance in vivo. Moreover, the load carry capacity and other mechanical properties essential to a fully optimized polymeric stent are difficult, timely and costly to establish. With the aim of compiling rapid and representative performance data for specific stent geometries, materials and designs, in addition to reducing experimental timeframes, Computational bench testing via finite element analysis (FEA) offers itself as a very powerful tool. On this basis, the research presented in this paper is concentrated on the finite element simulation of the mechanical performance of PLLA, which is a fully biodegradable polymer, in the stent application, using a non-linear viscous material model. Three physical stent geometries, typically used for fully polymeric stents, are selected, and a comparative study is performed in relation to their short-term mechanical performance, with the aid of experimental data. From the simulated output results, an informed understanding can be established in relation to radial strength, flexibility and longitudinal resistance, that can be compared with conventional permanent metal stent functionality, and the results show that it is indeed possible to generate a PLLA stent with comparable and sufficient mechanical performance. The paper also demonstrates the attractiveness of FEA as a tool

  16. Correlation between thromboelastography and traditional coagulation test parameters in hospitalized dogs

    Directory of Open Access Journals (Sweden)

    Rubanick JV

    2017-02-01

    Full Text Available Jean V Rubanick, Medora B Pashmakova, Micah A Bishop, James W Barr Department of Veterinary Small Animal Clinical Sciences, Texas A&M University, College Station, TX, USA Abstract: A hospital-based, prospective cross-sectional study was used to compare kaolin-activated thromboelastography (TEG parameters with traditional coagulation tests in 29 hospitalized dogs. Cases were included if the attending clinician requested coagulation testing. Blood was obtained from each dog and coagulation (prothrombin time, partial thromboplastin time, antithrombin activity, d-dimer concentration, and fibrinogen concentration and TEG analyses were performed. Hematocrit (Hct was also measured. Traditional coagulation results were evaluated for correlation with those from kaolin-activated TEG. Spearman’s correlation was used to calculate correlation coefficients. Fibrinogen was positively correlated with maximum amplitude (Pearson r=0.72, P<0.001 and global clot strength (Pearson r=0.72, P<0.001. There was no correlation between any of the remaining coagulation variables, TEG parameters, or Hct. Results of kaolin-activated TEG and traditional coagulation tests are not interchangeable means of monitoring coagulation derangements in this intensive care unit patient population. Determination of a true outcome measure is necessary to establish TEG’s clinical relevance to veterinary medicine. Keywords: TEG, thromboelastography, coagulation, hemostasis

  17. A goodness-of-fit test for occupancy models with correlated within-season revisits

    Science.gov (United States)

    Wright, Wilson; Irvine, Kathryn M.; Rodhouse, Thomas J.

    2016-01-01

    Occupancy modeling is important for exploring species distribution patterns and for conservation monitoring. Within this framework, explicit attention is given to species detection probabilities estimated from replicate surveys to sample units. A central assumption is that replicate surveys are independent Bernoulli trials, but this assumption becomes untenable when ecologists serially deploy remote cameras and acoustic recording devices over days and weeks to survey rare and elusive animals. Proposed solutions involve modifying the detection-level component of the model (e.g., first-order Markov covariate). Evaluating whether a model sufficiently accounts for correlation is imperative, but clear guidance for practitioners is lacking. Currently, an omnibus goodnessof- fit test using a chi-square discrepancy measure on unique detection histories is available for occupancy models (MacKenzie and Bailey, Journal of Agricultural, Biological, and Environmental Statistics, 9, 2004, 300; hereafter, MacKenzie– Bailey test). We propose a join count summary measure adapted from spatial statistics to directly assess correlation after fitting a model. We motivate our work with a dataset of multinight bat call recordings from a pilot study for the North American Bat Monitoring Program. We found in simulations that our join count test was more reliable than the MacKenzie–Bailey test for detecting inadequacy of a model that assumed independence, particularly when serial correlation was low to moderate. A model that included a Markov-structured detection-level covariate produced unbiased occupancy estimates except in the presence of strong serial correlation and a revisit design consisting only of temporal replicates. When applied to two common bat species, our approach illustrates that sophisticated models do not guarantee adequate fit to real data, underscoring the importance of model assessment. Our join count test provides a widely applicable goodness-of-fit test and

  18. A Test Bed for Short Pulse OA Detection of Optical Directors in Amphibious Operations

    National Research Council Canada - National Science Library

    Ertem, M

    1999-01-01

    ...) system to detect optical directors of potential threats in amphibious operations. The use of a short pulse duration allows discrimination of retroreflections from natural sources such as rock formations and vegetation...

  19. Thermal Vacuum Test Correlation of a Zero Propellant Load Case Thermal Capacitance Propellant Gauging Analytical Model

    Science.gov (United States)

    Mckim, Stephen A.

    2016-01-01

    This thesis describes the development and correlation of a thermal model that forms the foundation of a thermal capacitance spacecraft propellant load estimator. Specific details of creating the thermal model for the diaphragm propellant tank used on NASA's Magnetospheric Multiscale spacecraft using ANSYS and the correlation process implemented are presented. The thermal model was correlated to within plus or minus 3 degrees Celsius of the thermal vacuum test data, and was determined sufficient to make future propellant predictions on MMS. The model was also found to be relatively sensitive to uncertainties in applied heat flux and mass knowledge of the tank. More work is needed to improve temperature predictions in the upper hemisphere of the propellant tank where predictions were found to be 2 to 2.5 C lower than the test data. A road map for applying the model to predict propellant loads on the actual MMS spacecraft toward its end of life in 2017-2018 is also presented.

  20. Retrieval practice with short-answer, multiple-choice, and hybrid tests.

    Science.gov (United States)

    Smith, Megan A; Karpicke, Jeffrey D

    2014-01-01

    Retrieval practice improves meaningful learning, and the most frequent way of implementing retrieval practice in classrooms is to have students answer questions. In four experiments (N=372) we investigated the effects of different question formats on learning. Students read educational texts and practised retrieval by answering short-answer, multiple-choice, or hybrid questions. In hybrid conditions students first attempted to recall answers in short-answer format, then identified answers in multiple-choice format. We measured learning 1 week later using a final assessment with two types of questions: those that could be answered by recalling information verbatim from the texts and those that required inferences. Practising retrieval in all format conditions enhanced retention, relative to a study-only control condition, on both verbatim and inference questions. However, there were little or no advantages of answering short-answer or hybrid format questions over multiple-choice questions in three experiments. In Experiment 4, when retrieval success was improved under initial short-answer conditions, there was an advantage of answering short-answer or hybrid questions over multiple-choice questions. The results challenge the simple conclusion that short-answer questions always produce the best learning, due to increased retrieval effort or difficulty, and demonstrate the importance of retrieval success for retrieval-based learning activities.

  1. Experimental test of Bell`s inequalities using angular correlation of compton-scattered annihilation photons

    Energy Technology Data Exchange (ETDEWEB)

    Osuch, S.; Popkiewicz, M.; Szeflinski, Z.; Wilhelmi, Z. [Warsaw Univ., Inst. of Experimental Physics, Warsaw (Poland)

    1995-12-31

    The Bell`s inequality has been experimentally tested using angular correlation of Compton-scattered photons from annihilation of positrons emitted from {sup 22}Na source. The result shows a better agreement with the quantum mechanics predictions rather than with the Bell`s inequality. 7 refs, 5 figs, 1 tab.

  2. Experimental test of Bell's inequalities using angular correlation of compton-scattered annihilation photons

    International Nuclear Information System (INIS)

    Osuch, S.; Popkiewicz, M.; Szeflinski, Z.; Wilhelmi, Z.

    1995-01-01

    The Bell's inequality has been experimentally tested using angular correlation of Compton-scattered photons from annihilation of positrons emitted from 22 Na source. The result shows a better agreement with the quantum mechanics predictions rather than with the Bell's inequality

  3. Thermal Testing and Model Correlation of the Magnetospheric Multiscale (MMS) Observatories

    Science.gov (United States)

    Kim, Jong S.; Teti, Nicholas M.

    2015-01-01

    The Magnetospheric Multiscale (MMS) mission is a Solar Terrestrial Probes mission comprising four identically instrumented spacecraft that will use Earth's magnetosphere as a laboratory to study the microphysics of three fundamental plasma processes: magnetic reconnection, energetic particle acceleration, and turbulence. This paper presents the complete thermal balance (TB) test performed on the first of four observatories to go through thermal vacuum (TV) and the minibalance testing that was performed on the subsequent observatories to provide a comparison of all four. The TV and TB tests were conducted in a thermal vacuum chamber at the Naval Research Laboratory (NRL) in Washington, D.C. with the vacuum level higher than 1.3 x 10 (sup -4) pascals (10 (sup -6) torr) and the surrounding temperature achieving -180 degrees Centigrade. Three TB test cases were performed that included hot operational science, cold operational science and a cold survival case. In addition to the three balance cases a two hour eclipse and a four hour eclipse simulation was performed during the TV test to provide additional transient data points that represent the orbit in eclipse (or Earth's shadow) The goal was to perform testing such that the flight orbital environments could be simulated as closely as possible. A thermal model correlation between the thermal analysis and the test results was completed. Over 400 1-Wire temperature sensors, 200 thermocouples and 125 flight thermistor temperature sensors recorded data during TV and TB testing. These temperature versus time profiles and their agreements with the analytical results obtained using Thermal Desktop and SINDA/FLUINT are discussed. The model correlation for the thermal mathematical model (TMM) is conducted based on the numerical analysis results and the test data. The philosophy of model correlation was to correlate the model to within 3 degrees Centigrade of the test data using the standard deviation and mean deviation error

  4. Short-Range Correlated Magnetic Core-Shell CrO2/Cr2O3 Nanorods: Experimental Observations and Theoretical Considerations

    Directory of Open Access Journals (Sweden)

    Ashish C. Gandhi

    2018-05-01

    Full Text Available With the evolution of synthesis and the critical characterization of core-shell nanostructures, short-range magnetic correlation is of prime interest in employing their properties to develop novel devices and widespread applications. In this regard, a novel approach of the magnetic core-shell saturated magnetization (CSSM cylinder model solely based on the contribution of saturated magnetization in one-dimensional CrO2/Cr2O3 core-shell nanorods (NRs has been developed and applied for the determination of core-diameter and shell-thickness. The nanosized effect leads to a short-range magnetic correlation of ferromagnetic core-CrO2 extracted from CSSM, which can be explained using finite size scaling method. The outcome of this study is important in terms of utilizing magnetic properties for the critical characterization of core-shell nanomagnetic materials.

  5. Microscopic nucleon spectral function for finite nuclei featuring two- and three-nucleon short-range correlations: The model versus ab initio calculations for three-nucleon systems

    Science.gov (United States)

    Ciofi degli Atti, Claudio; Mezzetti, Chiara Benedetta; Morita, Hiko

    2017-04-01

    Background: Two-nucleon (2 N ) short-range correlations (SRC) in nuclei have been recently thoroughly investigated, both theoretically and experimentally and the study of three-nucleon (3 N ) SRC, which could provide important information on short-range hadronic structure, is underway. Novel theoretical ideas concerning 2 N and 3 N SRC are put forward in the present paper. Purpose: The general features of a microscopic one-nucleon spectral function which includes the effects of both 2 N and 3 N SRC and its comparison with ab initio spectral functions of the three-nucleon systems are illustrated. Methods: A microscopic and parameter-free one-nucleon spectral function expressed in terms of a convolution integral involving ab initio relative and center-of-mass (c.m.) momentum distributions of a 2 N pair and aimed at describing two- and three-nucleon short-range correlations, is obtained by using: (i) the two-nucleon momentum distributions obtained within ab initio approaches based upon nucleon-nucleon interactions of the Argonne family; (ii) the exact relation between one- and two-nucleon momentum distributions; (iii) the fundamental property of factorization of the nuclear wave function at short internucleon ranges. Results: The comparison between the ab initio spectral function of 3He and the one based upon the convolution integral shows that when the latter contains only two-nucleon short-range correlations the removal energy location of the peaks and the region around them exhibited by the ab initio spectral function are correctly predicted, unlike the case of the high and low removal energy tails; the inclusion of the effects of three-nucleon correlations brings the convolution model spectral function in much better agreement with the ab initio one; it is also found that whereas the three-nucleon short-range correlations dominate the high energy removal energy tail of the spectral function, their effects on the one-nucleon momentum distribution are almost one

  6. Evaluation of the E mu-pim-1 transgenic mouse model for short-term carcinogenicity testing

    DEFF Research Database (Denmark)

    van Kreijl, C. F.; van Oordt, C. W. V.; Kroese, E. D.

    1998-01-01

    of T-cell lymphomas. Because of the low incidence of spontaneous tumors and the increased sensitivity to N-ethyl-N-nitrosourea-induced carcinogenesis, E mu-pim-1 mice were suggested to be one of the first potential and attractive candidates to be used in short-term carcinogenicity testing...

  7. Digital Image Correlation Techniques Applied to Large Scale Rocket Engine Testing

    Science.gov (United States)

    Gradl, Paul R.

    2016-01-01

    Rocket engine hot-fire ground testing is necessary to understand component performance, reliability and engine system interactions during development. The J-2X upper stage engine completed a series of developmental hot-fire tests that derived performance of the engine and components, validated analytical models and provided the necessary data to identify where design changes, process improvements and technology development were needed. The J-2X development engines were heavily instrumented to provide the data necessary to support these activities which enabled the team to investigate any anomalies experienced during the test program. This paper describes the development of an optical digital image correlation technique to augment the data provided by traditional strain gauges which are prone to debonding at elevated temperatures and limited to localized measurements. The feasibility of this optical measurement system was demonstrated during full scale hot-fire testing of J-2X, during which a digital image correlation system, incorporating a pair of high speed cameras to measure three-dimensional, real-time displacements and strains was installed and operated under the extreme environments present on the test stand. The camera and facility setup, pre-test calibrations, data collection, hot-fire test data collection and post-test analysis and results are presented in this paper.

  8. Tensile strength of concrete under static and intermediate strain rates: Correlated results from different testing methods

    International Nuclear Information System (INIS)

    Wu Shengxing; Chen Xudong; Zhou Jikai

    2012-01-01

    Highlights: ► Tensile strength of concrete increases with increase in strain rate. ► Strain rate sensitivity of tensile strength of concrete depends on test method. ► High stressed volume method can correlate results from various test methods. - Abstract: This paper presents a comparative experiment and analysis of three different methods (direct tension, splitting tension and four-point loading flexural tests) for determination of the tensile strength of concrete under low and intermediate strain rates. In addition, the objective of this investigation is to analyze the suitability of the high stressed volume approach and Weibull effective volume method to the correlation of the results of different tensile tests of concrete. The test results show that the strain rate sensitivity of tensile strength depends on the type of test, splitting tensile strength of concrete is more sensitive to an increase in the strain rate than flexural and direct tensile strength. The high stressed volume method could be used to obtain a tensile strength value of concrete, free from the influence of the characteristics of tests and specimens. However, the Weibull effective volume method is an inadequate method for describing failure of concrete specimens determined by different testing methods.

  9. Patient-reported speech in noise difficulties and hyperacusis symptoms and correlation with test results.

    Science.gov (United States)

    Spyridakou, Chrysa; Luxon, Linda M; Bamiou, Doris E

    2012-07-01

    To compare self-reported symptoms of difficulty hearing speech in noise and hyperacusis in adults with auditory processing disorders (APDs) and normal controls; and to compare self-reported symptoms to objective test results (speech in babble test, transient evoked otoacoustic emission [TEOAE] suppression test using contralateral noise). A prospective case-control pilot study. Twenty-two participants were recruited in the study: 10 patients with reported hearing difficulty, normal audiometry, and a clinical diagnosis of APD; and 12 normal age-matched controls with no reported hearing difficulty. All participants completed the validated Amsterdam Inventory for Auditory Disability questionnaire, a hyperacusis questionnaire, a speech in babble test, and a TEOAE suppression test using contralateral noise. Patients had significantly worse scores than controls in all domains of the Amsterdam Inventory questionnaire (with the exception of sound detection) and the hyperacusis questionnaire (P reported symptoms of difficulty hearing speech in noise and speech in babble test results in the right ear (ρ = 0.624, P = .002), and between self-reported symptoms of hyperacusis and TEOAE suppression test results in the right ear (ρ = -0.597 P = .003). There was no significant correlation between the two tests. A strong correlation was observed between right ear speech in babble and patient-reported intelligibility of speech in noise, and right ear TEOAE suppression by contralateral noise and hyperacusis questionnaire. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  10. Strength and deformability of hollow concrete blocks: correlation of block and cylindrical sample test results

    OpenAIRE

    Barbosa, C. S.; Hanai, J.B.

    2009-01-01

    This paper deals with correlations among mechanical properties of hollow blocks and those of concrete used to make them. Concrete hollow blocks and test samples were moulded with plastic consistency concrete, to assure the same material in all cases, in three diferente levels of strength (nominally 10 N/mm², 20 N/mm² and 30 N/mm²). The mechanical properties and structural behaviour in axial compression and tension tests were determined by standard tests in blocks and cylinders. Stress and str...

  11. Correlation test to assess low-level processing of high-density oligonucleotide microarray data

    Directory of Open Access Journals (Sweden)

    Bergh Jonas

    2005-03-01

    Full Text Available Abstract Background There are currently a number of competing techniques for low-level processing of oligonucleotide array data. The choice of technique has a profound effect on subsequent statistical analyses, but there is no method to assess whether a particular technique is appropriate for a specific data set, without reference to external data. Results We analyzed coregulation between genes in order to detect insufficient normalization between arrays, where coregulation is measured in terms of statistical correlation. In a large collection of genes, a random pair of genes should have on average zero correlation, hence allowing a correlation test. For all data sets that we evaluated, and the three most commonly used low-level processing procedures including MAS5, RMA and MBEI, the housekeeping-gene normalization failed the test. For a real clinical data set, RMA and MBEI showed significant correlation for absent genes. We also found that a second round of normalization on the probe set level improved normalization significantly throughout. Conclusion Previous evaluation of low-level processing in the literature has been limited to artificial spike-in and mixture data sets. In the absence of a known gold-standard, the correlation criterion allows us to assess the appropriateness of low-level processing of a specific data set and the success of normalization for subsets of genes.

  12. Sample size for estimation of the Pearson correlation coefficient in cherry tomato tests

    Directory of Open Access Journals (Sweden)

    Bruno Giacomini Sari

    2017-09-01

    Full Text Available ABSTRACT: The aim of this study was to determine the required sample size for estimation of the Pearson coefficient of correlation between cherry tomato variables. Two uniformity tests were set up in a protected environment in the spring/summer of 2014. The observed variables in each plant were mean fruit length, mean fruit width, mean fruit weight, number of bunches, number of fruits per bunch, number of fruits, and total weight of fruits, with calculation of the Pearson correlation matrix between them. Sixty eight sample sizes were planned for one greenhouse and 48 for another, with the initial sample size of 10 plants, and the others were obtained by adding five plants. For each planned sample size, 3000 estimates of the Pearson correlation coefficient were obtained through bootstrap re-samplings with replacement. The sample size for each correlation coefficient was determined when the 95% confidence interval amplitude value was less than or equal to 0.4. Obtaining estimates of the Pearson correlation coefficient with high precision is difficult for parameters with a weak linear relation. Accordingly, a larger sample size is necessary to estimate them. Linear relations involving variables dealing with size and number of fruits per plant have less precision. To estimate the coefficient of correlation between productivity variables of cherry tomato, with a confidence interval of 95% equal to 0.4, it is necessary to sample 275 plants in a 250m² greenhouse, and 200 plants in a 200m² greenhouse.

  13. Sex-Dependent Individual Differences and the Correlational Relationship Between Proprioceptive and Verbal Tests

    Directory of Open Access Journals (Sweden)

    Liutsko Liudmila

    2014-09-01

    Full Text Available Introduction. The aim of the study was to analyze the relationship between proprioceptive and verbal tests on personality in both sexes separately due to existing proprioceptive differences in fine motor behavior between men and women in our previous studies [1, 2, 3]. Material and methods. 114 middle-aged participants from Belarus completed verbal tests (personality: Eysenck's EPQ, Big Five in Hromov's Russian adaptation, and Rosenberg's Self-esteem together with Proprioceptive Diagnostics of Temperament and Character (by Tous. Complementary information, such as tests of time perception, was collected and used in correlative and ANOVA analyses with the use of SPSS v.19. Results. The relationship between proprioceptive variables in personality and individual differences, time perception and the results of verbal tests were determined for each sex subgroup and discussed. ANOVA results reflected the corresponding differences and similarities between men and women in the variables of each test. Time perception was found to be significantly correlated to all five dimensions of the Big Five Test in both sexes, and both had a significant relationship to the same variables of the DP-TC test. Conclusions. Time perception can be used as an indirect indicator of personality. Existing individual and personality differences should be taken into account in coaching and education to obtain more effective results.

  14. Generalized correlation dimension - a way to analyze short time changes in non-linear dynamics of thermal plasma

    Czech Academy of Sciences Publication Activity Database

    Gruber, Jan

    2011-01-01

    Roč. 56, č. 2 (2011), s. 185-205 ISSN 0001-7043 Institutional research plan: CEZ:AV0Z20570509 Keywords : correlation dimension * time-embeddings * chaos Subject RIV: BL - Plasma and Gas Discharge Physics

  15. Psychometric evaluation of the Chinese version of short-form Test of Functional Health Literacy in Adolescents.

    Science.gov (United States)

    Chang, Li-Chun; Hsieh, Pei-Lin; Liu, Chieh-Hsing

    2012-09-01

    The purpose of this study is to develop and evaluate the psychometric properties of the Chinese version of short-form Test of Functional Health Literacy in Adolescents. Assessing health literacy is vital to design health education programme; however, there are no measurement tools exist for use specifically in Chinese adolescents. A non-experimental design was used to test the psychometric properties of the Test of Functional Health Literacy in Adolescents. The short-form Test of Functional Health Literacy in Adolescents was translated and back translated into a Chinese language version. Thirty high school students were recruited to validate the scenario of Test of Functional Health Literacy in Adolescents. Based on the multiple-stage stratified random sampling method, 300 high school students from four counties in Taiwan were invited to participate in this study to evaluate the psychometric properties of Test of Functional Health Literacy in Adolescents. The Functional Health Literacy in Adolescents had good internal consistency reliability and excellent test-retest reliability. Confirmatory factor analysis resulted in a one-factor solution. Contrary to the original version of the Test of Functional Health Literacy in Adolescents, the findings revealed that the 36-item, one-factor model for the Test of Functional Health Literacy in Adolescents is the best-fit model. This is a suitable instrument to assess health literacy levels in Chinese adolescents before health education programmes can be appropriately planned, implemented and evaluated. © 2012 Blackwell Publishing Ltd.

  16. Intraoperative leak testing has no correlation with leak after laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Sethi, Monica; Zagzag, Jonathan; Patel, Karan; Magrath, Melissa; Somoza, Eduardo; Parikh, Manish S; Saunders, John K; Ude-Welcome, Aku; Schwack, Bradley F; Kurian, Marina S; Fielding, George A; Ren-Fielding, Christine J

    2016-03-01

    Staple line leak is a serious complication of sleeve gastrectomy. Intraoperative methylene blue and air leak tests are routinely used to evaluate for leak; however, the utility of these tests is controversial. We hypothesize that the practice of routine intraoperative leak testing is unnecessary during sleeve gastrectomy. A retrospective cohort study was designed using a prospectively collected database of seven bariatric surgeons from two institutions. All patients who underwent sleeve gastrectomy from March 2012 to November 2014 were included. The performance of intraoperative leak testing and the type of test (air or methylene blue) were based on surgeon preference. Data obtained included BMI, demographics, comorbidity, presence of intraoperative leak test, result of test, and type of test. The primary outcome was leak rate between the leak test (LT) and no leak test (NLT) groups. SAS version 9.4 was used for univariate and multivariate analyses. A total of 1550 sleeve gastrectomies were included; most were laparoscopic (99.8%), except for one converted and two open cases. Routine intraoperative leak tests were performed in 1329 (85.7%) cases, while 221 (14.3%) did not have LTs. Of the 1329 cases with LTs, there were no positive intraoperative results. Fifteen (1%) patients developed leaks, with no difference in leak rate between the LT and NLT groups (1 vs. 1%, p = 0.999). After adjusting for baseline differences between the groups with a propensity analysis, the observed lack of association between leak and intraoperative leak test remained. In this cohort, leaks presented at a mean of 17.3 days postoperatively (range 1-67 days). Two patients with staple line leaks underwent repeat intraoperative leak testing at leak presentation, and the tests remained negative. Intraoperative leak testing has no correlation with leak due to laparoscopic sleeve gastrectomy and is not predictive of the later development of staple line leak.

  17. Selecting short-statured children needing growth hormone testing: Derivation and validation of a clinical decision rule

    Directory of Open Access Journals (Sweden)

    Bréart Gérard

    2008-07-01

    Full Text Available Abstract Background Numerous short-statured children are evaluated for growth hormone (GH deficiency (GHD. In most patients, GH provocative tests are normal and are thus in retrospect unnecessary. Methods A retrospective cohort study was conducted to identify predictors of growth hormone (GH deficiency (GHD in children seen for short stature, and to construct a very sensitive and fairly specific predictive tool to avoid unnecessary GH provocative tests. GHD was defined by the presence of 2 GH concentration peaks Results The initial study included 167 patients, 36 (22% of whom had GHD, including 5 (3% with certain GHD. Independent predictors of GHD were: growth rate Conclusion We have derived and performed an internal validation of a highly sensitive decision rule that could safely help to avoid more than 2/3 of the unnecessary GH tests. External validation of this rule is needed before any application.

  18. Comparison of Short-Term Estrogenicity Tests for Identification of Hormone-Disrupting Chemicals

    DEFF Research Database (Denmark)

    Andersen, Helle Raun; Andersson, Anna-Maria; Arnold, Steven F.

    1999-01-01

    The aim of this study was to compare results obtained by eight different short-term assays of estrogenlike actions of chemicals conducted in 10 different laboratories in five countries. Twenty chemicals were selected to represent direct-acting estrogens, compounds with estrogenic metabolites, est...

  19. Comparison of short-term estrogenicity tests for identification of hormone-disrupting chemicals

    DEFF Research Database (Denmark)

    Andersen, H R; Andersson, A M; Arnold, S F

    1999-01-01

    The aim of this study was to compare results obtained by eight different short-term assays of estrogenlike actions of chemicals conducted in 10 different laboratories in five countries. Twenty chemicals were selected to represent direct-acting estrogens, compounds with estrogenic metabolites, est...

  20. Pearson's chi-square test and rank correlation inferences for clustered data.

    Science.gov (United States)

    Shih, Joanna H; Fay, Michael P

    2017-09-01

    Pearson's chi-square test has been widely used in testing for association between two categorical responses. Spearman rank correlation and Kendall's tau are often used for measuring and testing association between two continuous or ordered categorical responses. However, the established statistical properties of these tests are only valid when each pair of responses are independent, where each sampling unit has only one pair of responses. When each sampling unit consists of a cluster of paired responses, the assumption of independent pairs is violated. In this article, we apply the within-cluster resampling technique to U-statistics to form new tests and rank-based correlation estimators for possibly tied clustered data. We develop large sample properties of the new proposed tests and estimators and evaluate their performance by simulations. The proposed methods are applied to a data set collected from a PET/CT imaging study for illustration. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  1. Pulmonary function tests correlated with thoracic volumes in adolescent idiopathic scoliosis.

    Science.gov (United States)

    Ledonio, Charles Gerald T; Rosenstein, Benjamin E; Johnston, Charles E; Regelmann, Warren E; Nuckley, David J; Polly, David W

    2017-01-01

    Scoliosis deformity has been linked with deleterious changes in the thoracic cavity that affect pulmonary function. The causal relationship between spinal deformity and pulmonary function has yet to be fully defined. It has been hypothesized that deformity correction improves pulmonary function by restoring both respiratory muscle efficiency and increasing the space available to the lungs. This research aims to correlate pulmonary function and thoracic volume before and after scoliosis correction. Retrospective correlational analysis between thoracic volume modeling from plain x-rays and pulmonary function tests was conducted. Adolescent idiopathic scoliosis patients enrolled in a multicenter database were sorted by pre-operative Total Lung Capacities (TLC) % predicted values from their Pulmonary Function Tests (PFT). Ten patients with the best and ten patients with the worst TLC values were included. Modeled thoracic volume and TLC values were compared before and 2 years after surgery. Scoliosis correction resulted in an increase in the thoracic volume for patients with the worst initial TLCs (11.7%) and those with the best initial TLCs (12.5%). The adolescents with the most severe pulmonary restriction prior to surgery strongly correlated with post-operative change in total lung capacity and thoracic volume (r 2  = 0.839; p volume in this group was 373.1 cm 3 (11.7%) which correlated with a 21.2% improvement in TLC. Scoliosis correction in adolescents was found to increase thoracic volume and is strongly correlated with improved TLC in cases with severe restrictive pulmonary function, but no correlation was found in cases with normal pulmonary function. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:175-182, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  2. Comparison of muscle/lean mass measurement methods: correlation with functional and biochemical testing.

    Science.gov (United States)

    Buehring, B; Siglinsky, E; Krueger, D; Evans, W; Hellerstein, M; Yamada, Y; Binkley, N

    2018-03-01

    DXA-measured lean mass is often used to assess muscle mass but has limitations. Thus, we compared DXA lean mass with two novel methods-bioelectric impedance spectroscopy and creatine (methyl-d3) dilution. The examined methodologies did not measure lean mass similarly and the correlation with muscle biomarkers/function varied. Muscle function tests predict adverse health outcomes better than lean mass measurement. This may reflect limitations of current mass measurement methods. Newer approaches, e.g., bioelectric impedance spectroscopy (BIS) and creatine (methyl-d3) dilution (D3-C), may more accurately assess muscle mass. We hypothesized that BIS and D3-C measured muscle mass would better correlate with function and bone/muscle biomarkers than DXA measured lean mass. Evaluations of muscle/lean mass, function, and serum biomarkers were obtained in older community-dwelling adults. Mass was assessed by DXA, BIS, and orally administered D3-C. Grip strength, timed up and go, and jump power were examined. Potential muscle/bone serum biomarkers were measured. Mass measurements were compared with functional and serum data using regression analyses; differences between techniques were determined by paired t tests. Mean (SD) age of the 112 (89F/23M) participants was 80.6 (6.0) years. The lean/muscle mass assessments were correlated (.57-.88) but differed (p Lean mass measures were unrelated to the serum biomarkers measured. These three methodologies do not similarly measure muscle/lean mass and should not be viewed as being equivalent. Functional tests assessing maximal muscle strength/power (grip strength and jump power) correlated with all mass measures whereas gait speed was not. None of the selected serum measures correlated with mass. Efforts to optimize muscle mass assessment and identify their relationships with health outcomes are needed.

  3. Correlation of accelerometry with clinical balance tests in older fallers and non-fallers.

    LENUS (Irish Health Repository)

    O'Sullivan, Maura

    2012-02-01

    BACKGROUND: falls are a common cause of injury and decreased functional independence in the older adult. Diagnosis and treatment of fallers require tools that accurately assess physiological parameters associated with balance. Validated clinical tools include the Berg Balance Scale (BBS) and the Timed Up and Go test (TUG); however, the BBS tends to be subjective in nature, while the TUG quantifies an individuals functional impairment but requires further subjective evaluation for balance assessment. Other quantitative alternatives to date require expensive, sophisticated equipment. Measurement of the acceleration of centre of mass, with relatively inexpensive, lightweight, body-mounted accelerometers is a potential solution to this problem. OBJECTIVES: to determine (i) if accelerometry correlates with standard clinical tests (BBS and TUG), (ii) to characterise accelerometer responses to increasingly difficult challenges to balance and (iii) to characterise acceleration patterns between fallers and non-fallers. Study design and setting: torso accelerations were measured at the level of L3 using a tri-axial accelerometer under four conditions; standing unsupported with eyes open (EO), eyes closed (EC) and on a mat with eyes open (MAT EO) and closed (MAT EC). Older patients (n = 21, 8 males, 13 females) with a mean age of 78 (SD +\\/- 7.6) years who attended a day hospital were recruited for this study. Patients were identified as fallers or non-fallers based on a comprehensive falls history. MEASUREMENTS: Spearman\\'s rank correlation analysis examined the relationship between acceleration root mean square (RMS) data and the BBS while Pearson\\'s correlation was used with TUG scores. Differences in accelerometer RMS between fallers and non-fallers and between test conditions were examined using t-test and non-parametric alternatives where appropriate. RESULTS: there was a stepwise increase in accelerometer RMS with increasing task complexity, and the accelerometer

  4. Correlation between Histological Status of the Pulp and Its Response to Sensibility Tests

    OpenAIRE

    Naseri, Mandana; Khayat, Akbar; Zamaheni, Sara; Shojaeian, Shiva

    2017-01-01

    Introduction: The purpose of this study was to assess the accuracy of sensibility tests by correlating it with histologic pulp condition. Methods and Materials: Assessment of clinical signs and symptoms were performed on 65 permanent teeth that were scheduled to be extracted for periodontal, prosthodontic or orthodontic reasons. The normal pulp and reversible pulpitis were considered as treatable tooth conditions while irreversible pulpitis and necrosis were considered as untreatable conditio...

  5. Short-circuit tests of 1650 and 96 MVA transformers for 1300 MW french nuclear power plants

    International Nuclear Information System (INIS)

    Mailhot, M.

    1989-01-01

    Power evacuation and feeding of the auxiliaries directly from the 400 kV grid are sensitive points governing the security of 1300 MW PWR Nuclear Power Plants of the French Program. These two different functions are provided by two specific types of transformers. - Banks of 3 single-phase 550 MVA - 400 kV/20 kV transformers. - Three-phase 96 MVA - 400 kV / 3 x 6.8 kV transformers. These passive elements must have a never failing reliability and assure a continuous service in spite of electric, thermal and mechanical stresses that may occur during the lifetime of the power plant. Dielectric and thermal tests carried out in the manufacturers test floors insure these stresses withstand capabilities of transformers. In France, high short-circuit power for the 400 kV network added to often low impedance voltages for transformers impose on them very high stresses during short-circuits. Calculation and experimentation on scale or partial models are not sufficient to insure short-circuit currents withstand capabilities of transformers. The margin of uncertainty dependent on obligatory extrapolations for this kind of complex systems [steel, magnetic sheets, copper, oil, paper and transformerboard] can be reduced in a significant way only by real scale tests on prototypes. These tests that need both high power and voltage cannot be performed in manufacturers test floors. So, in France they are carried out at the EDF Les Renardieres Laboratory. Following paper deals with SHELL TYPE TRANSFORMERS which, particularly thanks to their interleaved rectangular windings display a great resistance to short-circuit stresses

  6. Use of short-term test systems for the prediction of the hazard represented by potential chemical carcinogens

    International Nuclear Information System (INIS)

    Glass, L.R.; Jones, T.D.; Easterly, C.E.; Walsh, P.J.

    1990-10-01

    It has been hypothesized that results from short-term bioassays will ultimately provide information that will be useful for human health hazard assessment. Historically, the validity of the short-term tests has been assessed using the framework of the epidemiologic/medical screens. In this context, the results of the carcinogen (long-term) bioassay is generally used as the standard. However, this approach is widely recognized as being biased and, because it employs qualitative data, cannot be used to assist in isolating those compounds which may represent a more significant toxicologic hazard than others. In contrast, the goal of this research is to address the problem of evaluating the utility of the short-term tests for hazard assessment using an alternative method of investigation. Chemicals were selected mostly from the list of carcinogens published by the International Agency for Research on Carcinogens (IARC); a few other chemicals commonly recognized as hazardous were included. Tumorigenicity and mutagenicity data on 52 chemicals were obtained from the Registry of Toxic Effects of Chemical Substances (RTECS) and were analyzed using a relative potency approach. The data were evaluated in a format which allowed for a comparison of the ranking of the mutagenic relative potencies of the compounds (as estimated using short-term data) vs. the ranking of the tumorigenic relative potencies (as estimated from the chronic bioassays). Although this was a preliminary investigation, it offers evidence that the short-term tests systems may be of utility in ranking the hazards represented by chemicals which may contribute to increased carcinogenesis in humans as a result of occupational or environmental exposures. 177 refs., 8 tabs

  7. Use of short-term test systems for the prediction of the hazard represented by potential chemical carcinogens

    Energy Technology Data Exchange (ETDEWEB)

    Glass, L.R.; Jones, T.D.; Easterly, C.E.; Walsh, P.J.

    1990-10-01

    It has been hypothesized that results from short-term bioassays will ultimately provide information that will be useful for human health hazard assessment. Historically, the validity of the short-term tests has been assessed using the framework of the epidemiologic/medical screens. In this context, the results of the carcinogen (long-term) bioassay is generally used as the standard. However, this approach is widely recognized as being biased and, because it employs qualitative data, cannot be used to assist in isolating those compounds which may represent a more significant toxicologic hazard than others. In contrast, the goal of this research is to address the problem of evaluating the utility of the short-term tests for hazard assessment using an alternative method of investigation. Chemicals were selected mostly from the list of carcinogens published by the International Agency for Research on Carcinogens (IARC); a few other chemicals commonly recognized as hazardous were included. Tumorigenicity and mutagenicity data on 52 chemicals were obtained from the Registry of Toxic Effects of Chemical Substances (RTECS) and were analyzed using a relative potency approach. The data were evaluated in a format which allowed for a comparison of the ranking of the mutagenic relative potencies of the compounds (as estimated using short-term data) vs. the ranking of the tumorigenic relative potencies (as estimated from the chronic bioassays). Although this was a preliminary investigation, it offers evidence that the short-term tests systems may be of utility in ranking the hazards represented by chemicals which may contribute to increased carcinogenesis in humans as a result of occupational or environmental exposures. 177 refs., 8 tabs.

  8. Oblique penetration modeling and correlation with field tests into a soil target

    Energy Technology Data Exchange (ETDEWEB)

    Longcope, D.B. Jr. [Sandia National Labs., Albuquerque, NM (United States). Structural Dynamics Dept.

    1996-09-01

    An oblique penetration modeling procedure is evaluated by correlation with onboard acceleration data from a series of six penetration tests into Antelope Dry Lake soil at Tonopah Test Range, Nevada. The modeling represents both the loading which is coupled to the penetrator bending and the penetrator structure including connections between the major subsections. Model results show reasonable agreement with the data which validates the modeling procedure within a modest uncertainty related to accelerometer clipping and rattling of the telemetry package. The experimental and analytical results provide design guidance for the location and lateral restraint of components to reduce their shock environment.

  9. Three-Dimensional Digital Image Correlation of a Composite Overwrapped Pressure Vessel During Hydrostatic Pressure Tests

    Science.gov (United States)

    Revilock, Duane M., Jr.; Thesken, John C.; Schmidt, Timothy E.

    2007-01-01

    Ambient temperature hydrostatic pressurization tests were conducted on a composite overwrapped pressure vessel (COPV) to understand the fiber stresses in COPV components. Two three-dimensional digital image correlation systems with high speed cameras were used in the evaluation to provide full field displacement and strain data for each pressurization test. A few of the key findings will be discussed including how the principal strains provided better insight into system behavior than traditional gauges, a high localized strain that was measured where gages were not present and the challenges of measuring curved surfaces with the use of a 1.25 in. thick layered polycarbonate panel that protected the cameras.

  10. Microstructural evolution in the HAZ of Inconel 718 and correlation with the hot ductility test

    Science.gov (United States)

    Thompson, R. G.; Genculu, S.

    1983-01-01

    The nickel-base alloy 718 was evaluated to study the role of preweld heat treatment in reducing or eliminating heat-affected zone hot cracking. Three heat treatments were studied using the Gleeble hot ductility test. A modified hot ductility test was also used to follow the evolution of microstructure during simulated welding thermal cycles. The microstructural evolution was correlated with the hot ductility data in order to evaluate the mechanism of hot cracking in alloy 718. The correlation of hot ductility with microstructure showed that recrystallization, grain growth, and dissolution of precipitates did not in themselves cause any loss of ductility during cooling. Ductility loss during cooling was not initiated until the constitutional liquation of NbC particles was observed in the microstructure. Laves-type phases were found precipitated in the solidified grain boundaries but were not found to correlate with any ductility loss parameter. Mechanisms are reviewed which help to explain how heat treatment controls the hot crack susceptibility of alloy 718 as measured in the hot ductility test.

  11. On the use of SEM correlative tools for in situ mechanical tests.

    Science.gov (United States)

    Shi, Qiwei; Roux, Stéphane; Latourte, Félix; Hild, François; Loisnard, Dominique; Brynaert, Nicolas

    2018-01-01

    In situ SEM mechanical tests are key to study crystal plasticity. In particular, imaging and diffraction (EBSD) allow microstructure and surface kinematics to be monitored all along the test. However, to get a full benefit from different modalities, it is necessary to register all images and crystallographic orientation maps from EBSD into the same frame. Different correlative approaches tracking either Pt surface markings, crystal orientations or grain boundaries, allow such registrations to be performed and displacement as well as rotation fields to be measured, a primary information for crystal plasticity identification. However, the different contrasts that are captured in different modalities and unavoidable stage motions also give rise to artifacts that are to be corrected to register the different information onto the same material points. The same image correlation tools reveal very powerful to correct such artifacts. Illustrated by an in situ uniaxial tensile test performed on a bainitic-ferritic steel sample, recent advances in image correlation techniques are reviewed and shown to provide a comprehensive picture of local strain and rotation maps. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. CORRELATION OF ULTRASOUND (USG FINDINGS WITH SEROLOGICAL TESTS IN DENGUE FEVER

    Directory of Open Access Journals (Sweden)

    Dayanand

    2016-02-01

    Full Text Available INTRODUCTION Dengue is an endemic and epidemic disease of the tropical and subtropical regions. Between September & October 2012, there was an established outbreak of dengue in Hoskote, near Bangalore. Dengue results in serositis, which can be imaged by ultrasonography. OBJECTIVE To correlate the USG findings with the serological tests in paediatric and adult patients. MATERIALS AND METHODS 110 patients with clinical suspicion of dengue fever during the above period underwent serological tests-NS1, IgM and IgG and were evaluated with USG of the abdomen and thorax. The USG findings were correlated with serological tests. RESULTS 67 Patients were seropositive, 43 were seronegative. The USG findings in seropositive paediatric patients (n=32 and adult patients (n=35 respectively were gall bladder (GB wall edema-27 & 31, hepatomegaly-12 &14, ascites-16 & 12, splenomegaly- 15 & 9, right pleural effusion-14 & 13, left and bilateral pleural effusion-7 & 5. CONCLUSION In our study GB wall edema significantly correlated with seropositivity (p value=0.032. Thus ultrasound is an efficient screening tool in a case of dengue outbreak.

  13. Resampling-based methods in single and multiple testing for equality of covariance/correlation matrices.

    Science.gov (United States)

    Yang, Yang; DeGruttola, Victor

    2012-06-22

    Traditional resampling-based tests for homogeneity in covariance matrices across multiple groups resample residuals, that is, data centered by group means. These residuals do not share the same second moments when the null hypothesis is false, which makes them difficult to use in the setting of multiple testing. An alternative approach is to resample standardized residuals, data centered by group sample means and standardized by group sample covariance matrices. This approach, however, has been observed to inflate type I error when sample size is small or data are generated from heavy-tailed distributions. We propose to improve this approach by using robust estimation for the first and second moments. We discuss two statistics: the Bartlett statistic and a statistic based on eigen-decomposition of sample covariance matrices. Both statistics can be expressed in terms of standardized errors under the null hypothesis. These methods are extended to test homogeneity in correlation matrices. Using simulation studies, we demonstrate that the robust resampling approach provides comparable or superior performance, relative to traditional approaches, for single testing and reasonable performance for multiple testing. The proposed methods are applied to data collected in an HIV vaccine trial to investigate possible determinants, including vaccine status, vaccine-induced immune response level and viral genotype, of unusual correlation pattern between HIV viral load and CD4 count in newly infected patients.

  14. CORRELATION OF LOW BACK PAIN WITH BODY MASS INDEX, FUNCTIONAL REACH TEST AMONG FEMALE NURSING PROFESSIONALS

    Directory of Open Access Journals (Sweden)

    Shameela .T .V

    2015-12-01

    Full Text Available Background: Among health care workers the highest level of work related back injuries are more affected in nurses. There were many studies done to assess low back pain by using different tools. So this study aimed to identify the prevalence low back pain disability among female nursing professionals and the association between BMI, functional reach test and low back pain, so that a better tool can be used during the clinical examination for the betterment of the patient. The objective of the study is to identify the prevalence of low back pain disability, the association of Low Back Pain(LBP with BMI and functional reach test among female nursing professionals. Methods: A total of 256 subjects were assessed for disability due to back pain using OswestryLBP Disability Questionnaire and the prevalence of disability was determined. The sit and reach test, forward reach test and their BMI were calculated for those who had a disability score of 20 and above (n=87. Results: Data was analyzed using Pearson’s correlation.The study result showed a significant correlation (p=0.03 of sit and reach test with low back pain disability scores. There was a negative correlationseen among BMI and LBP disability score forward reach test and LBP disability score, and BMI and no low back pain disability score. Conclusion: The prevalence of LBP disability among nursing professionals was 33.9%. This study suggest that sit and reach test can be used as an indicator of low back pain. Whereas BMI and forward reach test do not indicate low back pain.

  15. Testing Proposed Correlations Between Olduvai Gorge and Laetoli, Tanzania Using Tephra Composition

    Science.gov (United States)

    McHenry, L. J.

    2006-12-01

    Olduvai Gorge and Laetoli are well-known Plio-Pleistocene archaeological sites located 30 km apart in Tanzania. Both received volcanic input from the nearby Ngorongoro Volcanic Highlands (NVH), and together provide a sedimentary and volcanic record from about 4.3 Ma to the Holocene. Previous researchers have proposed likely temporal correlations between the two sites, using both faunal and volcanic evidence. Direct tephra correlation between these sites could create a regional stratigraphic framework for their fossil and paleoecological records. Here, one of the proposed correlations is tested using geochemical fingerprinting. The fossiliferous Laetolil and Ndolanya beds of Laetoli predate the deposition of the Olduvai Beds, however recent 39Ar/40Ar SCLF age dating has shown potential temporal overlap between the Naibadad (2.23-1.93 +/- 0.02; Mangea, 1993) and Olpiro Beds (2.06-2.01 +/- 0.03; Manega 1993) at Laetoli with the Naabi Ignimbrite (2.029 +/- 0.005 Ma, Walter et al. 1992) and lower Bed I at Olduvai. Both the Naibadad bed and lower Bed I also contain fresh quartz-bearing tephra, which can be used for geochemical correlation. Three Naibadad tuffs and five lower Bed I tuffs (Naabi Ignimbrite, coarse feldspar crystal tuff (CFCT), Tuff IA, and two ignimbrites near Ngorongoro) were analyzed by electron microprobe for phenocryst and glass composition and compared to test for possible correlations. Certain mineralogical features made such a correlation unlikely. None of the lower Bed I tuffs analyzed contain significant plagioclase, which is present in all of the Naibadad tuffs analyzed. One Naibadad tuff has a bimodal glass composition indistinguishable from the CFCT, however the CFCT is rich in hornblende, while this Naibadad tuff contains none. This mineralogical difference highlights the need for mineralogical in addition to glass geochemical data for tephra correlation. Ngorongoro crater is the likely source for the Naibadad and lower Bed I tuffs because it

  16. Correlation of analysis with high level vibration test results for primary coolant piping

    International Nuclear Information System (INIS)

    Park, Y.J.; Hofmayer, C.H.; Costello, J.F.

    1992-01-01

    Dynamic tests on a modified 1/2.5-scale model of pressurized water reactor (PWR) primary coolant piping were performed using a large shaking table at Tadotsu, Japan. The High Level Vibration Test (HLVT) program was part of a cooperative study between the United States (Nuclear Regulatory Commission/Brookhaven National Laboratory, NRC/BNL) and Japan (Ministry of International Trade and Industry/Nuclear Power Engineering Center). During the test program, the excitation level of each test run was gradually increased up to the limit of the shaking table and significant plastic strains, as well as cracking, were induced in the piping. To fully utilize the test results, NRC/BNL sponsored a project to develop corresponding analytical predictions for the nonlinear dynamic response of the piping for selected test runs. The analyses were performed using both simplified and detailed approaches. The simplified approaches utilize a linear solution and an approximate formulation for nonlinear dynamic effects such as the use of a deamplification factor. The detailed analyses were performed using available nonlinear finite element computer codes, including the MARC, ABAQUS, ADINA and WECAN codes. A comparison of various analysis techniques with the test results shows a higher prediction error in the detailed strain values in the overall response values. A summary of the correlation analyses was presented before the BNL. This paper presents a detailed description of the various analysis results and additional comparisons with test results

  17. Acceptance test for the linear motion actuator for the scanning slit of the HIE-ISOLDE short diagnostic boxes

    CERN Document Server

    Cantero, E D; Bravin, E; Sosa, A

    2014-01-01

    We performed experimental tests to characterize the mechanical accuracy of a linear actuator designed by the company AVS for the movement of the scanning slit of the HIE-ISOLDE short diagnostic boxes. The mechanism consists of a linear actuator composed of two guiding rods and a lead screw, with a full stroke of 135 mm. A specially designed blade was mounted on the actuator and the transverse positioning of the blade was monitored with a camera-based optical system while moving the actuator at speeds of up to 10 mm/s. The repeatability of the positioning of the blade after several cycles around predefined positions was also measured. The results of the measurements and a general inspection of the device show that the proposed solution fulfils the specifications. A full prototype of short diagnostic box for the HIE-ISOLDE project can now be built for testing.

  18. Correlations between the scores of computerized adaptive testing, paper and pencil tests, and the Korean Medical Licensing Examination

    Directory of Open Access Journals (Sweden)

    Mee Young Kim

    2005-06-01

    Full Text Available To evaluate the usefulness of computerized adaptive testing (CAT in medical school, the General Examination for senior medical students was administered as a paper and pencil test (P&P and using CAT. The General Examination is a graduate examination, which is also a preliminary examination for the Korean Medical Licensing Examination (KMLE. The correlations between the results of the CAT and P&P and KMLE were analyzed. The correlation between the CAT and P&P was 0.8013 (p=0.000; that between the CAT and P&P was 0.7861 (p=0.000; and that between the CAT and KMLE was 0.6436 (p=0.000. Six out of 12 students with an ability estimate below 0.52 failed the KMLE. The results showed that CAT could replace P&P in medical school. The ability of CAT to predict whether students would pass the KMLE was 0.5 when the criterion of the theta value was set at -0.52 that was chosen arbitrarily for the prediction of pass or failure.

  19. Correlation between liver function tests and metabolic syndrome in hepatitis-free elderly

    Directory of Open Access Journals (Sweden)

    Hung-Sheng Shang

    2015-01-01

    Full Text Available Background: We aimed to investigate the relationship between liver function tests (LFTs and metabolic syndrome (MetS as several studies have shown positive correlations between some of the LFTs, including alanine aminotransferase (ALT and γ-glutamyl transpeptidase (γ-GT, and MetS but have not fully explored the same in the elderly. Owing to the progress in public health, the aging of the general population becomes a major issue. Design: We enrolled subjects aged over 60 years who underwent routine health checkups in a Health Screening Center after excluding subjects with a history of hepatitis B or C infection, excessive alcohol consumption, liver fibrosis, cirrhosis, acute hepatitis, diabetes, hypertension, dyslipidemia, cardiovascular disease, or receiving medications for these diseases. Finally, 9,282 participants were eligible for analysis. Statistical Analysis: All data were tested for normal distribution with the Kolmogorov-Smirnov test and for homogeneity of variances with the Levene′s test. A t-test was used to evaluate the differences between the two groups. Univariate and multivariate regressions were used to observe correlations between different parameters. Receiver operating characteristic curves of each LFT were used to predict MetS. Areas under curves and 95% confidence interval were also estimated and compared. Results: With the exception of aspartate aminotransferase and α-fetal protein, the results of LFTs, including total and direct bilirubin, alkaline phosphatase (ALP, ALT, and γ-GT, were altered in the group with MetS. Furthermore, the levels of γ-GT in men and ALP in women were independently associated with all MetS components and had the highest areas under receiver operating characteristic curves. Conclusion: Abnormal LFTs are highly correlated with MetS in the hepatitis-free elderly, with levels of γ-GT in men and ALP in women being the most important factors. LFTs may represent an auxiliary tool for the

  20. Why wait if you can switch? A short term testing effect in cross-language recognition.

    NARCIS (Netherlands)

    Verkoeijen, Peter; Bouwmeester, Samantha; Camp, Gino

    2018-01-01

    Taking a memory test after an initial study phase produces better long-term retention than restudying the items, a phenomenon known as the testing effect. We propose that this effect emerges because testing strengthens semantic features of items’ memory traces, whereas restudying strengthens surface

  1. Effects of Two Short-Term Desensitization Methods in the Treatment of Test Anxiety

    Science.gov (United States)

    Richardson, Frank C.; Suinn, Richard M.

    1974-01-01

    Accelerated massed desensitization and anxiety management training were compared with standard systematic desensitization in terms of reducing self-reported test anxiety in high test-anxious college students. All three treatments significantly reduced test anxiety as compared with a waiting list control group. (Author)

  2. MK-801 and memantine act differently on short-term memory tested with different time-intervals in the Morris water maze test.

    Science.gov (United States)

    Duda, Weronika; Wesierska, Malgorzata; Ostaszewski, Pawel; Vales, Karel; Nekovarova, Tereza; Stuchlik, Ales

    2016-09-15

    N-methyl-d-aspartate receptors (NMDARs) play a crucial role in spatial memory formation. In neuropharmacological studies their functioning strongly depends on testing conditions and the dosage of NMDAR antagonists. The aim of this study was to assess the immediate effects of NMDAR block by (+)MK-801 or memantine on short-term allothetic memory. Memory was tested in a working memory version of the Morris water maze test. In our version of the test, rats underwent one day of training with 8 trials, and then three experimental days when rats were injected intraperitoneally with low- 5 (MeL), high - 20 (MeH) mg/kg memantine, 0.1mg/kg MK-801 or 1ml/kg saline (SAL) 30min before testing, for three consecutive days. On each experimental day there was just one acquisition and one test trial, with an inter-trial interval of 5 or 15min. During training the hidden platform was relocated after each trial and during the experiment after each day. The follow-up effect was assessed on day 9. Intact rats improved their spatial memory across the one training day. With a 5min interval MeH rats had longer latency then all rats during retrieval. With a 15min interval the MeH rats presented worse working memory measured as retrieval minus acquisition trial for path than SAL and MeL and for latency than MeL rats. MK-801 rats had longer latency than SAL during retrieval. Thus, the high dose of memantine, contrary to low dose of MK-801 disrupts short-term memory independent on the time interval between acquisition and retrieval. This shows that short-term memory tested in a working memory version of water maze is sensitive to several parameters: i.e., NMDA receptor antagonist type, dosage and the time interval between learning and testing. Copyright © 2016. Published by Elsevier B.V.

  3. Testing for Unit Roots in Small Panels with Short-run and Long-run Cross-sectional Dependencies

    OpenAIRE

    Yoosoon Chang; Wonho Song

    2009-01-01

    An IV approach, using as instruments non-linear transformations of the lagged levels, is explored to test for unit roots in panels with general dependency and heterogeneity across cross-sectional units. We allow not only for the cross-sectional dependencies of innovations, but also for the presence of co-integration across cross-sectional levels. Unbalanced panels and panels with differing individual short-run dynamics and cross-sectionally related dynamics are also permitted. We also more ca...

  4. Signal processing of data from short sample tests for the projection of conductor performance in ITER magnets

    International Nuclear Information System (INIS)

    Martovetsky, Nicolai

    2008-01-01

    Qualification of the ITER conductor is absolutely necessary. Testing large scale conductors is expensive and time-consuming. To test 3-4 m long straight samples in a bore of a split solenoid is a relatively economical way in comparison with the fabrication of a coil to be tested in a bore of a background field solenoid. However, testing short samples may give ambiguous results due to different constraints in current redistribution in the cable or other end effects which are not present in the large magnet. This paper discusses the processes taking place in the ITER conductor, conditions when conductor performance could be distorted and possible signal processing to deduce the behaviour of ITER conductors in ITER magnets from the test data

  5. Bronchial asthma: correlation of quantitative CT and the pulmonary function test

    International Nuclear Information System (INIS)

    Park, Gun; Jin, Gong Yong; Jeon, Su Bin; Han, Young Min

    2007-01-01

    The purpose of this study was to assess the availability of quantitative computed tomography (QCT) in the evaluation asthma patients and to correlate its use with the pulmonary function test (PFT). Thirty asthmatic patients and thirty normal volunteers were prospectively evaluated by the use of HRCT and the PFT. By using 16 slice MDCT, HRCT was performed from the apex to the base of both lungs at the end inspiration and end expiration periods in all patients and images were reconstructed to a thickness of 1 mm (window level: -750 HU, window width: 1,500 HU). We analyzed each image for the whole lung using the Pulmo CT program. PFTs including FVC and FEV1 were performed one week prior and one week after the completion of a HRCT. The Difference of QCT (the mean lung density and subrange ratio) between volunteers and asthmatic patients was analyzed by using the Student's t-test. Spearman's correlation test was used to determine the association between PFT and QCT. The mean lung density (MLD) and subrange ratio were lower in asthmatic patients than in volunteers for and expiration and no difference was seen between asthmatic patients and volunteers for end inspiration. FVC and FEV1 were lower in asthmatic patients than in volunteers. A decrease in FVC and FEV1 correlated with changes in the MLD and subrange ratio for end expiration. QCT such as MLD and the subrange ratio using HRCT can be used to indirectly assess the pulmonary function of the asthma patient. The PFT seems to correlate better with the MLD and subrange ratio for expiratory QCT of the asthma patient than with inspiratory QCT

  6. The test facility for the short prototypes of the LHC superconducting magnets

    International Nuclear Information System (INIS)

    Delsolaro, W. Venturini; Arn, A.; Bottura, L.; Giloux, C.; Mompo, R.; Siemko, A.; Walckiers, L.

    2002-01-01

    The LHC development program relies on cryogenic tests of prototype and model magnets. This vigorous program is pursued in a dedicated test facility based on several vertical cryostats working at superfluid helium temperatures. The performance of the facility is detailed. Goals and test equipment for currently performed studies are reviewed: quench analysis and magnet protection studies, measurement of the field quality, test of ancillary electrical equipment like diodes and busbars. The paper covers the equipment available for tests of prototypes and some special series of LHC magnets to come

  7. The test facility for the short prototypes of the LHC superconducting magnets

    Science.gov (United States)

    Delsolaro, W. Venturini; Arn, A.; Bottura, L.; Giloux, C.; Mompo, R.; Siemko, A.; Walckiers, L.

    2002-05-01

    The LHC development program relies on cryogenic tests of prototype and model magnets. This vigorous program is pursued in a dedicated test facility based on several vertical cryostats working at superfluid helium temperatures. The performance of the facility is detailed. Goals and test equipment for currently performed studies are reviewed: quench analysis and magnet protection studies, measurement of the field quality, test of ancillary electrical equipment like diodes and busbars. The paper covers the equipment available for tests of prototypes and some special series of LHC magnets to come.

  8. Comparison of the clonidine test with the insulin tolerance test in the evaluation of patients with short stature

    International Nuclear Information System (INIS)

    Batista, M.C.

    1986-01-01

    Thirty one patients aged 2.9 to 17.5 years, with heights from 1.3 to 85 standard deviations below the mean for age and sex, are studied. Two GH provocative tests are done: (1) insulin tolerance test (ITT): intravenous regular insulin 0.1 U/kg body weight; (2) clonidine test (CLOT): oral clonidine 0.0375 mg/m 2 surface area. Serum GH is measured by a radioimmunoassay method developed in the laboratory and calibrated against a reference preparation provided by the National Institutes of Health. (M.A.C.) [pt

  9. Correlação entre testes de vigor em sementes de maxixe Correlation among vigor tests on gherkin seeds

    Directory of Open Access Journals (Sweden)

    Salvador Barros Torres

    1999-06-01

    -CPATSA, at Petrolina, PE, Brazil, from January to May 1996. In the lab tests, a completely randomized design was used, and in the field tests, a randomized block design was used - both of them with four repetitions of fifty seeds, being the means compared by the Tukey test, at 1% of probability. The germination and vigor tests were effective to detect differences of physiological quality among gherkin seed lots. The damage control and cold without soil tests were more stable on the division of the lots by the vigor levels and, at the same time, showed the highest correlation with field emergency.

  10. Comparison of the neural correlates of retrieval success in tests of cued recall and recognition memory.

    Science.gov (United States)

    Okada, Kayoko; Vilberg, Kaia L; Rugg, Michael D

    2012-03-01

    The neural correlates of successful retrieval on tests of word stem recall and recognition memory were compared. In the recall test, subjects viewed word stems, half of which were associated with studied items and half with unstudied items, and for each stem attempted to recall a corresponding study word. In the recognition test, old/new judgments were made on old and new words. The neural correlates of successful retrieval were identified by contrasting activity elicited by correctly endorsed test items. Old > new effects common to the two tasks were found in medial and lateral parietal and right entorhinal cortex. Common new > old effects were identified in medial and left frontal cortex, and left anterior intra-parietal sulcus. Greater old > new effects were evident for cued recall in inferior parietal regions abutting those demonstrating common effects, whereas larger new > old effects were found for recall in left frontal cortex and the anterior cingulate. New > old effects were also found for the recall task in right lateral anterior prefrontal cortex, where they were accompanied by old > new effects during recognition. It is concluded that successful recall and recognition are associated with enhanced activity in a common set of recollection-sensitive parietal regions, and that the greater activation in these regions during recall reflects the greater dependence of that task on recollection. Larger new > old effects during recall are interpreted as reflections of the greater opportunity for iterative retrieval attempts when retrieval cues are partial rather than copy cues. Copyright © 2011 Wiley Periodicals, Inc.

  11. Change of liver echogenicity in chronic renal failure: Correlation with serologic test and pathologic findings

    International Nuclear Information System (INIS)

    Eun, Hyo Won; Cho, Kyoung Sik; Kim, Jeong Kon; Kim, Jung Hoon

    2002-01-01

    To correlate serologic test and pathologic findings with change of hepatic parenchymal echogenicity on ultrasound (US) in patients with chronic renal failure. From January 1995 to April 2000, among eight hundred eighty four patients with kidney transplantation due to chronic renal failure, sixty seven patients who underwent US-guided liver biopsy were selected. Change of liver echogenicity on US was analyzed, and this change was compared with serologic test and pathologic findings. Among sixty seven patients, pathologic findings of thirty four patients with the normal liver echogenicity on US revealed normal in 15 patients (44%), viral hepatitis in 18 (53%), and liver cirrhosis in one patient (3%). Meanwhile, twenty seven patients with chronic liver disease on US were pathologically confirmed as normal in 13 patients (48%), viral hepatitis in 11 (40%), liver cirrhosis in four patients (11%); six patients with cirrhotic change on US, liver cirrhosis in four patients (67%) and viral hepatitis on two patients (33%). Serologic test of thirty four patients with the normal liver echogenicity on US showed positive HBs Ag in 17 patients (50%), positive anti-HCV Ab in 11 (32%), positive in both HBs Ag and anti-HCV Ab in one (3%), and normal result in five patients (15%). In patients with chronic renal failure, it is nor enough to determine the presence of liver disease only based on change of echogenicity on US. A careful correlation with serologic test and, if needed, pathologic confirmation are recommended for the accurate preoperative evaluation of the liver.

  12. NRC test results and operations experience provide insights for a new gate valve stem force correlation

    International Nuclear Information System (INIS)

    Watkins, John C.; Steele, Robert Jr.; DeWall, Kevin G.; Weidenhamer, G.H.; Rothberg, O.O.

    1994-01-01

    This paper presents the results of testing sponsored by the NRC to assess valve and motor operator performance under varying pressure and fluid conditions. This effort included an examination of the methods used by the industry to predict the required stem force of a valve, and research to provide guidelines for the extrapolation of in situ test results to design basis conditions.Years ago, when most of these valves were originally installed, the industry used a set of equations to determine analytically that the valves' motor-operators were large enough and the control switches were set high enough to close the valves at their design basis conditions. Our research has identified several inconsistencies with the industry's existing gate valve stem force equation and has challenged the overly simplistic assumptions inherent in its use. This paper discusses the development of the INEL correlation, which serves as the basis for a method to bound the stem force necessary to close flexwedge gate valves whose operational characteristics have been shown to be predictable. As utilities undertake to provide assurance of their valves' operability, this ability to predict analytically the required stem force is especially important for valves that cannot be tested at design basis conditions. For such valves, the results of tests conducted at less severe conditions can be used with the INEL correlation to make the necessary prediction. ((orig.))

  13. Comparison of infrared and 3D digital image correlation techniques applied for mechanical testing of materials

    Science.gov (United States)

    Krstulović-Opara, Lovre; Surjak, Martin; Vesenjak, Matej; Tonković, Zdenko; Kodvanj, Janoš; Domazet, Željko

    2015-11-01

    To investigate the applicability of infrared thermography as a tool for acquiring dynamic yielding in metals, a comparison of infrared thermography with three dimensional digital image correlation has been made. Dynamical tension tests and three point bending tests of aluminum alloys have been performed to evaluate results obtained by IR thermography in order to detect capabilities and limits for these two methods. Both approaches detect pastification zone migrations during the yielding process. The results of the tension test and three point bending test proved the validity of the IR approach as a method for evaluating the dynamic yielding process when used on complex structures such as cellular porous materials. The stability of the yielding process in the three point bending test, as contrary to the fluctuation of the plastification front in the tension test, is of great importance for the validation of numerical constitutive models. The research proved strong performance, robustness and reliability of the IR approach when used to evaluate yielding during dynamic loading processes, while the 3D DIC method proved to be superior in the low velocity loading regimes. This research based on two basic tests, proved the conclusions and suggestions presented in our previous research on porous materials where middle wave infrared thermography was applied.

  14. Full-scale locomotive dynamic collision testing and correlations : offset collisions between a locomotive and a covered hopper car (test 4).

    Science.gov (United States)

    2011-09-01

    This report presents the test results and finite element correlations of a full-scale dynamic collision test with rail vehicles as part of the Federal Railroad Administrations research program on improved crashworthiness of locomotive structures. ...

  15. Testing the effect of a short cheap talk script in choice experiments

    DEFF Research Database (Denmark)

    Ladenburg, Jacob; Dahlgaard, Jens Olav; Bonnichsen, Ole

    as hypothetical bias. The present paper attempts to frame the description of the hypothetical market so as to induce more “true market behaviour” in the respondents by including a short Cheap Talk script. The script informs respondents that in similar studies using stated preference methods, people have...... to be a preference mover, but does not affect preferences significantly. Significant effects are found when relating the effect of the Cheap Talk script to the cost levels of the alternatives, in that female respondents are found to choose higher cost alternatives less frequently when presented with the Cheap Talk...

  16. Testing the effect of a short cheap talk script in choice experiments

    DEFF Research Database (Denmark)

    Ladenburg, Jacob; Bonnichsen, Ole; Dahlgaard, Jens Olav

    2011-01-01

    as hypothetical bias. The present paper attempts to frame the description of the hypothetical market so as to induce more “true market behaviour” in the respondents by including a short Cheap Talk script. The script informs respondents that in similar studies using stated preference methods, people have...... the demand for visual impact mitigation, but does not affect preferences significantly. Significant effects are found when relating the effect of the Cheap Talk script to the cost levels of the alternatives, in that female respondents are found to choose higher cost alternatives less frequently when...

  17. The conservation pattern of short linear motifs is highly correlated with the function of interacting protein domains

    Directory of Open Access Journals (Sweden)

    Wang Yiguo

    2008-10-01

    Full Text Available Abstract Background Many well-represented domains recognize primary sequences usually less than 10 amino acids in length, called Short Linear Motifs (SLiMs. Accurate prediction of SLiMs has been difficult because they are short (often Results Our combined approach revealed that SLiMs are highly conserved in proteins from functional classes that are known to interact with a specific domain, but that they are not conserved in most other protein groups. We found that SLiMs recognized by SH2 domains were highly conserved in receptor kinases/phosphatases, adaptor molecules, and tyrosine kinases/phosphatases, that SLiMs recognized by SH3 domains were highly conserved in cytoskeletal and cytoskeletal-associated proteins, that SLiMs recognized by PDZ domains were highly conserved in membrane proteins such as channels and receptors, and that SLiMs recognized by S/T kinase domains were highly conserved in adaptor molecules, S/T kinases/phosphatases, and proteins involved in transcription or cell cycle control. We studied Tyr-SLiMs recognized by SH2 domains in more detail, and found that SH2-recognized Tyr-SLiMs on the cytoplasmic side of membrane proteins are more highly conserved than those on the extra-cellular side. Also, we found that SH2-recognized Tyr-SLiMs that are associated with SH3 motifs and a tyrosine kinase phosphorylation motif are more highly conserved. Conclusion The interactome of protein domains is reflected by the evolutionary conservation of SLiMs recognized by these domains. Combining scoring matrixes derived from peptide libraries and conservation analysis, we would be able to find those protein groups that are more likely to interact with specific domains.

  18. Correlations between the simulated military tasks performance and physical fitness tests at high altitude

    Directory of Open Access Journals (Sweden)

    Eduardo Borba Neves

    2017-11-01

    Full Text Available The aim of this study was to investigate the Correlations between the Simulated Military Tasks Performance and Physical Fitness Tests at high altitude. This research is part of a project to modernize the physical fitness test of the Colombian Army. Data collection was performed at the 13th Battalion of Instruction and Training, located 30km south of Bogota D.C., with a temperature range from 1ºC to 23ºC during the study period, and at 3100m above sea level. The sample was composed by 60 volunteers from three different platoons. The volunteers start the data collection protocol after 2 weeks of acclimation at this altitude. The main results were the identification of a high positive correlation between the 3 Assault wall in succession and the Simulated Military Tasks performance (r = 0.764, p<0.001, and a moderate negative correlation between pull-ups and the Simulated Military Tasks performance (r = -0.535, p<0.001. It can be recommended the use of the 20-consecutive overtaking of the 3 Assault wall in succession as a good way to estimate the performance in operational tasks which involve: assault walls, network of wires, military Climbing Nets, Tarzan jump among others, at high altitude.

  19. Correlation of Descriptive Analysis and Instrumental Puncture Testing of Watermelon Cultivars.

    Science.gov (United States)

    Shiu, J W; Slaughter, D C; Boyden, L E; Barrett, D M

    2016-06-01

    The textural properties of 5 seedless watermelon cultivars were assessed by descriptive analysis and the standard puncture test using a hollow probe with increased shearing properties. The use of descriptive analysis methodology was an effective means of quantifying watermelon sensory texture profiles for characterizing specific cultivars' characteristics. Of the 10 cultivars screened, 71% of the variation in the sensory attributes was measured using the 1st 2 principal components. Pairwise correlation of the hollow puncture probe and sensory parameters determined that initial slope, maximum force, and work after maximum force measurements all correlated well to the sensory attributes crisp and firm. These findings confirm that maximum force correlates well with not only firmness in watermelon, but crispness as well. The initial slope parameter also captures the sensory crispness of watermelon, but is not as practical to measure in the field as maximum force. The work after maximum force parameter is thought to reflect cellular arrangement and membrane integrity that in turn impact sensory firmness and crispness. Watermelon cultivar types were correctly predicted by puncture test measurements in heart tissue 87% of the time, although descriptive analysis was correct 54% of the time. © 2016 Institute of Food Technologists®

  20. Structural identification of short/middle span bridges by rapid impact testing: theory and verification

    International Nuclear Information System (INIS)

    Zhang, Jian; Wu, Z S; Zhang, Q Q; Guo, S L; Xu, D W

    2015-01-01

    A structural strain flexibility identification method by processing the multiple-reference impact testing data is proposed. First, a kind of novel long-gauge fiber optic sensor is developed for structural macro-strain monitoring. Second, the multiple-reference impact testing technology is employed, during which both the impacting force and structural strain responses are measured. The impact testing technology has unique merit because it is able to extract exact structural frequency response functions (FRFs), while other test methods, for instance ambient tests, can only output the FRFs with scaled magnitudes. Most importantly, the originality of the article is that a method of identifying the structural strain flexibility characteristic from the impact test data has been proposed, which is useful for structural static strain prediction and capacity evaluation. Examples of a six meter simple supported beam and a multiple-span continuous beam bridge have successfully verified the effectiveness of the proposed method. (paper)

  1. Structural identification of short/middle span bridges by rapid impact testing: theory and verification

    Science.gov (United States)

    Zhang, Jian; Zhang, Q. Q.; Guo, S. L.; Xu, D. W.; Wu, Z. S.

    2015-06-01

    A structural strain flexibility identification method by processing the multiple-reference impact testing data is proposed. First, a kind of novel long-gauge fiber optic sensor is developed for structural macro-strain monitoring. Second, the multiple-reference impact testing technology is employed, during which both the impacting force and structural strain responses are measured. The impact testing technology has unique merit because it is able to extract exact structural frequency response functions (FRFs), while other test methods, for instance ambient tests, can only output the FRFs with scaled magnitudes. Most importantly, the originality of the article is that a method of identifying the structural strain flexibility characteristic from the impact test data has been proposed, which is useful for structural static strain prediction and capacity evaluation. Examples of a six meter simple supported beam and a multiple-span continuous beam bridge have successfully verified the effectiveness of the proposed method.

  2. Concreteness effects in short-term memory: a test of the item-order hypothesis.

    Science.gov (United States)

    Roche, Jaclynn; Tolan, G Anne; Tehan, Gerald

    2011-12-01

    The following experiments explore word length and concreteness effects in short-term memory within an item-order processing framework. This framework asserts order memory is better for those items that are relatively easy to process at the item level. However, words that are difficult to process benefit at the item level for increased attention/resources being applied. The prediction of the model is that differential item and order processing can be detected in episodic tasks that differ in the degree to which item or order memory are required by the task. The item-order account has been applied to the word length effect such that there is a short word advantage in serial recall but a long word advantage in item recognition. The current experiment considered the possibility that concreteness effects might be explained within the same framework. In two experiments, word length (Experiment 1) and concreteness (Experiment 2) are examined using forward serial recall, backward serial recall, and item recognition. These results for word length replicate previous studies showing the dissociation in item and order tasks. The same was not true for the concreteness effect. In all three tasks concrete words were better remembered than abstract words. The concreteness effect cannot be explained in terms of an item-order trade off. PsycINFO Database Record (c) 2011 APA, all rights reserved.

  3. The correlative analysis between CBF measured by SPECT and Chinese reading test in childhood reading disorder

    International Nuclear Information System (INIS)

    Wu Yonggang; Su Jianzhi; He Jianjun; Yang Zhiwei; Liu Guofeng

    2002-01-01

    Objective: To investigate changes of cerebral blood flow (CBF) and its association with Chinese reading skill diagnostic test (CRSDT) in childhood reading disorder (RD). Methods: In 25 RD children and 20 age-matched control subjects, the authors quantitatively determined CBF and regional cerebral blood flow (rCBF) with SPECT using the non-blood-withdrew method. The authors studied the correlation between the CBF and the total raw scores by CRSDT. Results: CBF in case group was (38.87 +- 3.77) ml·100 g -1 ·min -1 and was significantly lower than that in control group [43.65 +- 2.64) mL·100 g -1 ·min -1 (P < 0.01)]. These reduction in CBF correlated with the total raw scores by CRSDT. Conclusion: These results suggest the children with reading disorder have CBF reduction and SPECT is useful for evaluation of cerebral functioning in reading disorder children

  4. Test and Analysis Correlation of Form Impact onto Space Shuttle Wing Leading Edge RCC Panel 8

    Science.gov (United States)

    Fasanella, Edwin L.; Lyle, Karen H.; Gabrys, Jonathan; Melis, Matthew; Carney, Kelly

    2004-01-01

    Soon after the Columbia Accident Investigation Board (CAIB) began their study of the space shuttle Columbia accident, "physics-based" analyses using LS-DYNA were applied to characterize the expected damage to the Reinforced Carbon-Carbon (RCC) leading edge from high-speed foam impacts. Forensic evidence quickly led CAIB investigators to concentrate on the left wing leading edge RCC panels. This paper will concentrate on the test of the left-wing RCC panel 8 conducted at Southwest Research Institute (SwRI) and the correlation with an LS-DYNA analysis. The successful correlation of the LS-DYNA model has resulted in the use of LS-DYNA as a predictive tool for characterizing the threshold of damage for impacts of various debris such as foam, ice, and ablators onto the RCC leading edge for shuttle return-to-flight.

  5. Testing the correlation of fragmented pollen records of the middle and late Pleistocene temperate stages

    DEFF Research Database (Denmark)

    Kuneš, Petr; Odgaard, Bent Vad

    Quaternary temperate stages have long been described based on changing pollen abundances of various tree taxa in lacustrine sediments. Later, attempts have been made to assign such biostratigraphic units to distinct marine isotope stages (MIS). Existing continuous chronosequences from Southern...... records depends on site-to-site correlations. This comparison has often been performed on a visual basis, lacking clearly defined protocols and statements of underlying assumptions. Here I test the correlation of well and poorly known pollen records of the middle- and late-Pleistocene temperate stages...... from Northern-Central Europe and evaluate the usefulness of several numerical techniques. TWINSPAN analysis identifies groups of temperate stages based on presence/absence of their indicative taxa and may be useful for distinguishing between older and younger interglacials. Site-to-site sequence...

  6. Short-term glucagon stimulation test of C-peptide effect on glucose utilization in patients with type 1 diabetes mellitus.

    Science.gov (United States)

    Mojto, Viliam; Rausova, Zuzana; Chrenova, Jana; Dedik, Ladislav

    2015-12-01

    This work aimed to evaluate the use of a four-point glucagon stimulation test of C-peptide effect on glucose utilization in type 1 diabetic patients using a new mathematical model. A group of 32 type 1 diabetic patients and a group of 10 healthy control subjects underwent a four-point glucagon stimulation test with blood sampling at 0, 6, 15 and 30 min after 1 mg glucagon bolus intravenous administration. Pharmacokinetic and pharmacokinetic/pharmacodynamic models of C-peptide effect on glucose utilization versus area under curve (AUC) were used. A two-sample t test and ANOVA with Bonferroni correction were used to test the significance of differences between parameters. A significant difference between control and patient groups regarding the coefficient of whole-body glucose utilization and AUC C-peptide/AUC glucose ratio (p ≪ 0.001 and p = 0.002, respectively) was observed. The high correlation (r = 0.97) between modeled coefficient of whole-body glucose utilization and numerically calculated AUC C-peptide/AUC glucose ratio related to entire cohort indicated the stability of used method. The short-term four-point glucagon stimulation test allows the numerically calculated AUC C-peptide/AUC glucose ratio and/or the coefficient of whole-body glucose utilization calculated from model to be used to diagnostically identify type 1 diabetic patients.

  7. Comparison of short-term estrogenicity tests for identification of hormone-disrupting chemicals

    DEFF Research Database (Denmark)

    Andersen, H R; Andersson, A M; Arnold, S F

    1999-01-01

    induced a strong estrogenic response in all test systems. Colchicine caused cytotoxicity only. Bisphenol A induced an estrogenic response in all assays. The results obtained for the remaining test compounds--tamoxifen, ICI 182.780, testosterone, bisphenol A dimethacrylate, 4-n-octylphenol, 4-n...

  8. A Short Test for the Assessment of Basic Knowledge in Psychology

    Science.gov (United States)

    Peter, Johannes; Leichner, Nikolas; Mayer, Anne-Kathrin; Krampen, Günter

    2015-01-01

    This paper reports the development of a fixed-choice test for the assessment of basic knowledge in psychology, for use with undergraduate as well as graduate students. Test content is selected based on a core concepts approach and includes a sample of concepts which are indexed most frequently in common introductory psychology textbooks. In a…

  9. Short-term practice effects and variability in cognitive testing in a healthy elderly population

    DEFF Research Database (Denmark)

    Krenk, L.; Rasmussen, L.S.; Siersma, V.

    2012-01-01

    BACKGROUND: Cognitive decline in the elderly is a subject of intense focus. However, there is a lack of consensus regarding definition of significant decline in connection with repeated testing and the interpretation of cognitive tests results must take into account the practice effect...

  10. Efficient statistical tests to compare Youden index: accounting for contingency correlation.

    Science.gov (United States)

    Chen, Fangyao; Xue, Yuqiang; Tan, Ming T; Chen, Pingyan

    2015-04-30

    Youden index is widely utilized in studies evaluating accuracy of diagnostic tests and performance of predictive, prognostic, or risk models. However, both one and two independent sample tests on Youden index have been derived ignoring the dependence (association) between sensitivity and specificity, resulting in potentially misleading findings. Besides, paired sample test on Youden index is currently unavailable. This article develops efficient statistical inference procedures for one sample, independent, and paired sample tests on Youden index by accounting for contingency correlation, namely associations between sensitivity and specificity and paired samples typically represented in contingency tables. For one and two independent sample tests, the variances are estimated by Delta method, and the statistical inference is based on the central limit theory, which are then verified by bootstrap estimates. For paired samples test, we show that the estimated covariance of the two sensitivities and specificities can be represented as a function of kappa statistic so the test can be readily carried out. We then show the remarkable accuracy of the estimated variance using a constrained optimization approach. Simulation is performed to evaluate the statistical properties of the derived tests. The proposed approaches yield more stable type I errors at the nominal level and substantially higher power (efficiency) than does the original Youden's approach. Therefore, the simple explicit large sample solution performs very well. Because we can readily implement the asymptotic and exact bootstrap computation with common software like R, the method is broadly applicable to the evaluation of diagnostic tests and model performance. Copyright © 2015 John Wiley & Sons, Ltd.

  11. Dietary exposure to 5-hydroxymethylfurfural from Norwegian food and correlations with urine metabolites of short-term exposure.

    Science.gov (United States)

    Husøy, T; Haugen, M; Murkovic, M; Jöbstl, D; Stølen, L H; Bjellaas, T; Rønningborg, C; Glatt, H; Alexander, J

    2008-12-01

    5-Hydroxymethylfurfural (HMF) is formed in carbohydrate-rich food during acid-catalysed dehydration and in the Maillard reaction from reducing sugars. HMF is found in mg quantities per kg in various foods. HMF is mainly metabolised to 5-hydroxymethyl-2-furoic acid (HMFA), but unknown quantities of the mutagenic 5-sulphoxymethylfurfural (SMF) may also be formed, making HMF potentially hazardous to humans. We determined the HMF content in Norwegian food items and estimated the dietary intake of HMF in 53 volunteers by means of 24h dietary recall. The estimated intakes of HMF were correlated with urinary excretion of HMFA. Coffee, prunes, dark beer, canned peaches and raisins had the highest levels of HMF. The 95th percentile of the estimated daily dietary intake of HMF and the 24h urinary excretion of HMFA were 27.6 and 28.6mg, respectively. Coffee, dried fruit, honey and alcohol were identified as independent determinants of urinary HMFA excretion. Most participants had lower estimated HMF intake than the amount of HMFA excreted in urine. In spite of this there was a significant correlation (r=0.57, P<0.001) between the estimated HMF intake and urinary HMFA. Further studies are needed to reveal alternative sources for HMF exposure.

  12. Reliability, Validity, and Minimal Detectable Change of Balance Evaluation Systems Test and Its Short Versions in Older Cancer Survivors: A Pilot Study.

    Science.gov (United States)

    Huang, Min H; Miller, Kara; Smith, Kristin; Fredrickson, Kayle; Shilling, Tracy

    2016-01-01

    .86-2.47 points), and MDC (2.39-6.86 points). The Bland-Altman plot revealed no systematic errors. The scores of BESTest, Mini-BEST, and Brief-BEST were correlated significantly with those of ABC Scale (P test-retest reliability, and excellent concurrent validity with the ABC Scale for community-dwelling cancer survivors aged 55 years and older who had completed cancer treatments for at least 3 months. Future studies are necessary to determine the predictive values for determining fall risks using balance assessment tools in older cancer survivors. Clinicians can utilize the BESTest and its short versions to evaluate balance problems in community-dwelling older cancer survivors and apply the established MDC to assess the intervention outcomes.

  13. Correlation potential of a test ion near a strongly charged plate.

    Science.gov (United States)

    Lu, Bing-Sui; Xing, Xiangjun

    2014-03-01

    We analytically calculate the correlation potential of a test ion near a strongly charged plate inside a dilute m:-n electrolyte. We do this by calculating the electrostatic Green's function in the presence of a nonlinear background potential, the latter having been obtained using the nonlinear Poisson-Boltzmann theory. We consider the general case where the dielectric constants of the plate and the electrolyte are distinct. The following generic results emerge from our analyses: (1) If the distance to the plate Δz is much larger than a Gouy-Chapman length, the plate surface will behave effectively as an infinitely charged surface, and the dielectric constant of the plate effectively plays no role. (2) If Δz is larger than a Gouy-Chapman length but shorter than a Debye length, the correlation potential can be interpreted in terms of an image charge that is three times larger than the source charge. This behavior is independent of the valences of the ions. (3) The Green's function vanishes inside the plate if the surface charge density is infinitely large; hence the electrostatic potential is constant there. In this respect, a strongly charged plate behaves like a conductor plate. (4) If Δz is smaller than a Gouy-Chapman length, the correlation potential is dominated by the conventional image charge due to the dielectric discontinuity at the interface. (5) If Δz is larger than a Debye length, the leading order behavior of the correlation potential will depend on the valences of the ions in the electrolyte. Furthermore, inside an asymmetric electrolyte, the correlation potential is singly screened, i.e., it undergoes exponential decay with a decay width equal to the Debye length.

  14. Thermal Vacuum Test Correlation of A Zero Propellant Load Case Thermal Capacitance Propellant Gauging Analytics Model

    Science.gov (United States)

    McKim, Stephen A.

    2016-01-01

    This thesis describes the development and test data validation of the thermal model that is the foundation of a thermal capacitance spacecraft propellant load estimator. Specific details of creating the thermal model for the diaphragm propellant tank used on NASA's Magnetospheric Multiscale spacecraft using ANSYS and the correlation process implemented to validate the model are presented. The thermal model was correlated to within plus or minus 3 degrees Centigrade of the thermal vacuum test data, and was found to be relatively insensitive to uncertainties in applied heat flux and mass knowledge of the tank. More work is needed, however, to refine the thermal model to further improve temperature predictions in the upper hemisphere of the propellant tank. Temperatures predictions in this portion were found to be 2-2.5 degrees Centigrade lower than the test data. A road map to apply the model to predict propellant loads on the actual MMS spacecraft toward its end of life in 2017-2018 is also presented.

  15. Correlation between chronic arthritis patients confirmed with questionnaire and serologic test of Lyme disease

    Science.gov (United States)

    Rotan, H.; Ginting, Y.; Loesnihari, R.; Kembaren, T.; Marpaung, B.

    2018-03-01

    Lyme borreliosis is the most common tick-borne disease, and frequency of arthritis complication later. The objective of this study was to determine the seroprevalence of Lyme disease and to evaluate its correlation with chronic arthritis. This epidemiologic cross sectional study included 41 healthy individuals who had chronic arthritis and bitten by ticks underwent questionnaires, and laboratory tests consisted of a routine blood sample, serum uric acid, and IgG ELISA for Lyme. There was 7.32% presence of positive IgG for Lyme. Samples with positive IgG for Lyme were further evaluated for rheumatology marker. We found three samples with a positive rheumatoid factor, two samples had positive anti-MCV, and 1 sample had slightly increased CRP. Three Lyme positive samples had normal EULAR scoring. It was the first Lyme disease case found in Indonesia, particularly in 4 villages of Sibolangit, Deli Serdang, North Sumatera. The assessment made by analysis the questionnaire, evaluation the blood test, and confirmed positive Lyme disease, and at last, we found the correlation between chronic arthritis with positive test Lyme.

  16. Air trapping on HRCT in asthmatics: correlation with pulmonary function test

    International Nuclear Information System (INIS)

    Hwang, Jung Hwa; Cha, Chull Hee; Park, Jai Soung; Kim, Young Beom; Lee, Hae Kyung; Choi, Deuk Lin; Kim, Kyung Ho; Park, Choon Sik

    1997-01-01

    To evaluate on the basis of the pulmonary function test the correlation between the extent of air trapping on HRCT with the severity of airway obstruction and also to identify the prognostic effect of the extent of air trapping after treatment of asthma. Thirty five patients with clinically diagnosed bronchial asthma and air trapping, as seen on HRCT, were included in this study. We quantitatively analysed on HRCT the extent of air trapping and then statistically compared this with the clinical parameters of the pulmonary function test. We classified the patients into two groups on the basis of the pulmonary function test and clinical status : Group 1 (N=35), the total number of asthmatic patients; Group 2 (N=18), relatively stable asthmatics without acute asthmatic attack who showed FEV1 of more than 80% of the predicted value. Using the functional paramenters of PEFR, one of the obijective indicators of improvement in airway obstruction, we also classified the patients into three groups on the basis of interval between treatment and clinical improvement. The result of this was as follows : group 1, asymptomatic group (initial PEFR within normal limit, N=7); group 2, early responder (improvement of PEFR within three hospital days, N=18); group 3, late responder (improvement of PEFR within fourteen hospital days should there be a number here). Using HRCT, we then statistically analysed the differences between the three groups in the extent of air trapping. Among the total of 35 asthmatics, the extent of air trapping on HRCT showed significant correlation with FEV1 (r= -0.6161, p < 0.001) and MEFR (r= -0.6012, p < 0.001). Among the relatively stable asthmatics who showed FEV1 more than 80% of the predicted value, MEFR (r= -0.7553, p < 0.001) and FEF75 (r= -0.7529, p=0.012) showed statistically significant correlation with the extent of air trapping on HRCT, but there was no significant correlation between air trapping on HRCT and FEV1. In the three groups of

  17. Air trapping on HRCT in asthmatics: correlation with pulmonary function test

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jung Hwa; Cha, Chull Hee; Park, Jai Soung; Kim, Young Beom; Lee, Hae Kyung; Choi, Deuk Lin; Kim, Kyung Ho; Park, Choon Sik [Soonchunhyang Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-02-01

    To evaluate on the basis of the pulmonary function test the correlation between the extent of air trapping on HRCT with the severity of airway obstruction and also to identify the prognostic effect of the extent of air trapping after treatment of asthma. Thirty five patients with clinically diagnosed bronchial asthma and air trapping, as seen on HRCT, were included in this study. We quantitatively analysed on HRCT the extent of air trapping and then statistically compared this with the clinical parameters of the pulmonary function test. We classified the patients into two groups on the basis of the pulmonary function test and clinical status : Group 1 (N=35), the total number of asthmatic patients; Group 2 (N=18), relatively stable asthmatics without acute asthmatic attack who showed FEV1 of more than 80% of the predicted value. Using the functional paramenters of PEFR, one of the obijective indicators of improvement in airway obstruction, we also classified the patients into three groups on the basis of interval between treatment and clinical improvement. The result of this was as follows : group 1, asymptomatic group (initial PEFR within normal limit, N=7); group 2, early responder (improvement of PEFR within three hospital days, N=18); group 3, late responder (improvement of PEFR within fourteen hospital days should there be a number here). Using HRCT, we then statistically analysed the differences between the three groups in the extent of air trapping. Among the total of 35 asthmatics, the extent of air trapping on HRCT showed significant correlation with FEV1 (r= -0.6161, p < 0.001) and MEFR (r= -0.6012, p < 0.001). Among the relatively stable asthmatics who showed FEV1 more than 80% of the predicted value, MEFR (r= -0.7553, p < 0.001) and FEF75 (r= -0.7529, p=0.012) showed statistically significant correlation with the extent of air trapping on HRCT, but there was no significant correlation between air trapping on HRCT and FEV1. In the three groups of

  18. Correlation Between Haematological Parameters, Kidney Function Tests and Liver Function Tests in Plasmodium Falciparum and Vivax Malaria

    Directory of Open Access Journals (Sweden)

    Mitul Chhatriwala

    2017-12-01

    Full Text Available Abstract: Malaria remains a major cause of morbidity and mortality in India. Plasmodium falciparum remains the main culprit although cases with vivax malaria are on the rise. Severe malaria as defined by the WHO criteria has high rate of complications and mortality. In our study we recruited microscopy positive falciparum and vivax malaria patients. Haematological and biochemical laboratory investigations were carried out in recruited patients. Both parameters were found to be significantly derailed in falciparum cases as compared to vivax. A direct correlation has been observed between kidney function tests (serum creatinine,serum urea and direct bilirubin levels across all cases of malaria. Hence these parameters can be used to identify and monitor the progress of cases of severe malaria as significant proportion of patients fulfilled the criteria of severe malaria in the cohort.

  19. Degree of skin denervation and its correlation to objective thermal sensory test in leprosy patients.

    Directory of Open Access Journals (Sweden)

    Ismael Alves Rodrigues Júnior

    Full Text Available BACKGROUND: Leprosy is an infectious disease affecting skin and peripheral nerves resulting in increased morbidity and physical deformities. Early diagnosis provides opportune treatment and reduces its complications, relying fundamentally on the demonstration of impaired sensation in suggestive cutaneous lesions. The loss of tactile sensitivity in the lesions is preceded by the loss of thermal sensitivity, stressing the importance of the thermal test in the suspicious lesions approach. The gold-standard method for the assessment of thermal sensitivity is the quantitative sensory test (QST. Morphological study may be an alternative approach to access the thin nerve fibers responsible for thermal sensitivity transduction. The few studies reported in leprosy patients pointed out a rarefaction of thin dermo-epidermal fibers in lesions, but used semi-quantitative evaluation methods. METHODOLOGY/PRINCIPAL FINDINGS: This work aimed to study the correlation between the degree of thermal sensitivity impairment measured by QST and the degree of denervation in leprosy skin lesions, evaluated by immunohistochemistry anti-PGP 9.5 and morphometry. Twenty-two patients were included. There were significant differences in skin thermal thresholds among lesions and contralateral skin (cold, warm, cold induced pain and heat induced pain. The mean reduction in the density of intraepidermal and subepidermal fibers in lesions was 79.5% (SD = 19.6 and 80.8% (SD = 24.9, respectively. CONCLUSIONS/SIGNIFICANCE: We observed a good correlation between intraepidermal and subepidermal fibers deficit, but no correlation between these variables and those accounting for the degree of impairment in thermal thresholds, since the thin fibers rarefaction was homogeneously intense in all patients, regardless of the degree of sensory deficit. We believe that the homogeneously intense denervation in leprosy lesions should be objective of further investigations focused on its

  20. Application of Computational Fluid Dynamics (CFD) in transonic wind-tunnel/flight-test correlation

    Science.gov (United States)

    Murman, E. M.

    1982-01-01

    The capability for calculating transonic flows for realistic configurations and conditions is discussed. Various phenomena which were modeled are shown to have the same order of magnitude on the influence of predicted results. It is concluded that CFD can make the following contributions to the task of correlating wind tunnel and flight test data: some effects of geometry differences and aeroelastic distortion can be predicted; tunnel wall effects can be assessed and corrected for; and the effects of model support systems and free stream nonuniformities can be modeled.

  1. Correlated X-ray/UV/optical emission and short-term variability in a Seyfert 1 galaxy NGC 4593

    Science.gov (United States)

    Pal, Main; Naik, Sachindra

    2018-03-01

    We present a detailed multifrequency analysis of an intense monitoring programme of Seyfert 1 galaxy NGC 4593 over a duration of nearly for a month with Swift observatory. We used 185 pointings to study the variability in six ultraviolet/optical and two soft (0.3-1.5 keV) and hard X-ray (1.5-10 keV) bands. The amplitude of the observed variability is found to decrease from high energy to low energy (X-ray to optical) bands. Count-count plots of ultraviolet/optical bands with hard X-rays clearly suggest the presence of a mixture of two major components: (i) highly variable component such as hard X-ray emission, and (ii) slowly varying disc-like component. The variations observed in the ultraviolet/optical emission are strongly correlated with the hard X-ray band. Cross-correlation analysis provides the lags for the longer wavelengths compared to the hard X-rays. Such lags clearly suggest that the changes in the ultraviolet/optical bands follow the variations in the hard X-ray band. This implies that the observed variation in longer wavelengths is due to X-ray reprocessing. Though, the measured lag spectrum (lag versus wavelength) is well described by λ4/3 as expected from the standard disc model, the observed lags are found to be longer than the predicted values from standard disc model. This implies that the actual size of the disc of NGC 4593 is larger than the estimated size of standard thin disc as reported in active galactic nuclei such as NGC 5548 and Fairall 9.

  2. Pitfalls and important issues in testing reliability using intraclass correlation coefficients in orthopaedic research.

    Science.gov (United States)

    Lee, Kyoung Min; Lee, Jaebong; Chung, Chin Youb; Ahn, Soyeon; Sung, Ki Hyuk; Kim, Tae Won; Lee, Hui Jong; Park, Moon Seok

    2012-06-01

    Intra-class correlation coefficients (ICCs) provide a statistical means of testing the reliability. However, their interpretation is not well documented in the orthopedic field. The purpose of this study was to investigate the use of ICCs in the orthopedic literature and to demonstrate pitfalls regarding their use. First, orthopedic articles that used ICCs were retrieved from the Pubmed database, and journal demography, ICC models and concurrent statistics used were evaluated. Second, reliability test was performed on three common physical examinations in cerebral palsy, namely, the Thomas test, the Staheli test, and popliteal angle measurement. Thirty patients were assessed by three orthopedic surgeons to explore the statistical methods testing reliability. Third, the factors affecting the ICC values were examined by simulating the data sets based on the physical examination data where the ranges, slopes, and interobserver variability were modified. Of the 92 orthopedic articles identified, 58 articles (63%) did not clarify the ICC model used, and only 5 articles (5%) described all models, types, and measures. In reliability testing, although the popliteal angle showed a larger mean absolute difference than the Thomas test and the Staheli test, the ICC of popliteal angle was higher, which was believed to be contrary to the context of measurement. In addition, the ICC values were affected by the model, type, and measures used. In simulated data sets, the ICC showed higher values when the range of data sets were larger, the slopes of the data sets were parallel, and the interobserver variability was smaller. Care should be taken when interpreting the absolute ICC values, i.e., a higher ICC does not necessarily mean less variability because the ICC values can also be affected by various factors. The authors recommend that researchers clarify ICC models used and ICC values are interpreted in the context of measurement.

  3. Systematic reviews: I. The correlation between laboratory tests on marginal quality and bond strength. II. The correlation between marginal quality and clinical outcome.

    Science.gov (United States)

    Heintze, Siegward D

    2007-01-01

    An accepted principle in restorative dentistry states that restorations should be placed with the best marginal quality possible to avoid postoperative sensitivity, marginal discoloration, and secondary caries. Different laboratory methods claim to predict the clinical performance of restorative materials, for example, tests of bond strength and microleakage and gap analysis. The purpose of this review was twofold: (1) find studies that correlated the results of bond strength tests with either microleakage or gap analysis for the same materials, and (2) find studies that correlated the results of microleakage and/or gaps with the clinical parameters for the same materials. Furthermore, influencing factors on the results of the laboratory tests were reviewed and assessed. For the first question, searches for studies were conducted in the MEDLINE database and IADR/AADR abtracts online with specific search and inclusion criteria. The outcome for each study was assessed on the basis of the statistical test applied in the study, and finally the number of studies with or without correlation was compiled. For the second question, results of the quantitative marginal analysis of Class V restorations published by the University of Zürich with the same test protocol and prospective clinical trials were searched that investigated the same materials for at least 2 years in Class V cavities. Pearson correlation coefficients were calculated for pooled data of materials and clinical outcome parameters such as retention loss, marginal discoloration, marginal integrity, and secondary caries. For the correlation of dye penetration and clinical outcome, studies on Class V restorations published by the same research institute were searched in MEDLINE that examined the same adhesive systems as the selected clinical trials. For the correlation bond strength/microleakage, 30 studies were included into the review, and for the correlation bond strength/gap analysis 18 studies. For both

  4. Strength and deformability of hollow concrete blocks: correlation of block and cylindrical sample test results

    Directory of Open Access Journals (Sweden)

    C. S. Barbosa

    Full Text Available This paper deals with correlations among mechanical properties of hollow blocks and those of concrete used to make them. Concrete hollow blocks and test samples were moulded with plastic consistency concrete, to assure the same material in all cases, in three diferente levels of strength (nominally 10 N/mm², 20 N/mm² and 30 N/mm². The mechanical properties and structural behaviour in axial compression and tension tests were determined by standard tests in blocks and cylinders. Stress and strain analyses were made based on concrete’s modulus of elasticity obtained in the sample tests as well as on measured strain in the blocks’ face-shells and webs. A peculiar stress-strain analysis, based on the superposition of effects, provided an estimation of the block load capacity based on its deformations. In addition, a tentative method to preview the block deformability from the concrete mechanical properties is described and tested. This analysis is a part of a broader research that aims to support a detailed structural analysis of blocks, prisms and masonry constructions.

  5. Correlation between hypoosmotic swelling test and breeding soundness evaluation of adult Nelore bulls

    Directory of Open Access Journals (Sweden)

    Tamires Miranda Neto

    2011-07-01

    Full Text Available This study aimed at evaluating the relationship between physical and morphological semen features with the hypoosmotic swelling (HOS test in raw semen of adult Nelore bulls classified as sound and unsound for breeding. Two hundred and six Nelore bulls aging from 3-10 years old were subjected to breeding soundness examination. After physical and morphological semen examination, HOS test was done. After the breeding soundness examination, 94.2% of the bulls were classified as sound for breeding. There was no difference between the average scrotal circumference of bulls classified as sound and unsound for breeding (P>0.05, but there was difference between all semen physical and morphological aspects of bulls classified as sound and unsound for breeding (P>0.05, but there was no difference in the mean percentage of reactive spermatozoa to HOS test results both for sound (38.4±17.9 and unsound animals (39.5±16.4; P>0.05, with no Pearson correlation between the HOS test and variables. According to these results HOS test can not be used alone to predict the reproductive potential of adult Nelore bulls.

  6. Is a sequence of tests during urethral pressure profilometry correlated with symptoms assessment in women?

    Science.gov (United States)

    Valentini, Françoise A; Robain, Gilberte; Marti, Brigitte G

    2012-01-01

    Our purpose was, applying a strictly defined protocol for urethral profilometry, 1) to test the repeatability of same session rest maximum urethral closure pressure (MUCP) and 2) to search for correlation between women complaint and the changes in MUCP value (rest and dynamic tests). A population of 140 consecutive women referred for evaluation of lower urinary tract dysfunction was stratified in 4 groups according with the urinary symptoms: stress, urge, mixed incontinence and continent and in each group in 3 age groups (young, middle age and old). The sequence of tests recorded in supine position was: urethral pressure profile at rest bladder empty, after bladder filling at 250 mL (reference test), stress profile, fatigability (before (rest) and after 10 successive strong coughs), then in standing position. In all groups, there was no significant difference between the two MUCP values at rest bladder filled. In the three incontinent groups, MUCP was higher bladder empty than bladder filled (p rest bladder filled has a good repeatability in individual. However a complex sequence of tests during urethral pressure profilometry remains discussed in middle-age and old age-groups, it allows specifying the stress component of incontinence in young women and the urgency component in all age-groups.

  7. Long-range versus short-range correlations in the two-neutron transfer reaction 64Ni(18O,16O)66Ni

    Science.gov (United States)

    Paes, B.; Santagati, G.; Vsevolodovna, R. Magana; Cappuzzello, F.; Carbone, D.; Cardozo, E. N.; Cavallaro, M.; García-Tecocoatzi, H.; Gargano, A.; Ferreira, J. L.; Lenzi, S. M.; Linares, R.; Santopinto, E.; Vitturi, A.; Lubian, J.

    2017-10-01

    Recently, various two-neutron transfer studies using the (18O,16O) reaction were performed with a large success. This was achieved because of a combined use of the microscopic quantum description of the reaction mechanism and of the nuclear structure. In the present work we use this methodology to study the two-neutron transfer reaction of the 18O+64Ni system at 84 MeV incident energy, to the ground and first 2+ excited state of the residual 66Ni nucleus. All the experimental data were measured by the large acceptance MAGNEX spectrometer at the Instituto Nazionale di Fisica Nucleare -Laboratori Nazionali del Sud (Italy). We have performed exact finite range cross section calculations using the coupled channel Born approximation (CCBA) and coupled reaction channel (CRC) method for the sequential and direct two-neutron transfers, respectively. Moreover, this is the first time that the formalism of the microscopic interaction boson model (IBM-2) was applied to a two-neutron transfer reaction. From our results we conclude that for two-neutron transfer to the ground state of 66Ni, the direct transfer is the dominant reaction mechanism, whereas for the transfer to the first excited state of 66Ni, the sequential process dominates. A competition between long-range and short-range correlations is discussed, in particular, how the use of two different models (Shell model and IBM's) help to disentangle long- and short-range correlations.

  8. Psychometric Evaluation and Cultural Correlates of the Mate Retention Inventory–Short Form (MRI-SF in Iran

    Directory of Open Access Journals (Sweden)

    Mohammad Atari

    2017-02-01

    Full Text Available The current study investigated the psychometric properties of the Persian translation of the Mate Retention Inventory–Short Form (MRI-SF in Iran. We also investigated sex differences in the use of mate retention tactics and investigated the relationships between mate retention behaviors and a number of related cultural constructs. Participants (N = 308 ranged in age from 18 to 57 years. All participants were in a committed romantic relationship, with mean relationship length of 63.5 months (SD = 73.8. Participants completed the Persian translation of the MRI-SF and measures of religiosity, relationship satisfaction, self-esteem, and socioeconomic status. Cultural measures specific to Iran were also included, such as Mahr (for married individuals, self-perceived Qeiratiness (for men, and self-perceived jealousy (for women. Mahr is a mandatory amount of money or possessions paid or promised to be paid by the groom to the bride at the time of the marriage contract. Qeirati is a male-specific adjective in Persian meaning protective against unwanted attention toward a man’s romantic partner. Female jealousy is usually regarded the counterpart of male Qeiratiness in Iranian culture. The 19 mate retention tactics formed a two-component structure, consistent with previous research. Results demonstrate adequate internal consistency of 2-item assessments of mate retention tactics. Observed sex differences accorded with previous mate retention research and are discussed in reference to evolutionary perspectives on human mating. Several significant associations emerged between mate retention tactics and Iranian culture-specific variables and are discussed from a cross-cultural perspective.

  9. Correlation analysis between pulmonary function test parameters and CT image parameters of emphysema

    Science.gov (United States)

    Liu, Cheng-Pei; Li, Chia-Chen; Yu, Chong-Jen; Chang, Yeun-Chung; Wang, Cheng-Yi; Yu, Wen-Kuang; Chen, Chung-Ming

    2016-03-01

    Conventionally, diagnosis and severity classification of Chronic Obstructive Pulmonary Disease (COPD) are usually based on the pulmonary function tests (PFTs). To reduce the need of PFT for the diagnosis of COPD, this paper proposes a correlation model between the lung CT images and the crucial index of the PFT, FEV1/FVC, a severity index of COPD distinguishing a normal subject from a COPD patient. A new lung CT image index, Mirage Index (MI), has been developed to describe the severity of COPD primarily with emphysema disease. Unlike conventional Pixel Index (PI) which takes into account all voxels with HU values less than -950, the proposed approach modeled these voxels by different sizes of bullae balls and defines MI as a weighted sum of the percentages of the bullae balls of different size classes and locations in a lung. For evaluation of the efficacy of the proposed model, 45 emphysema subjects of different severity were involved in this study. In comparison with the conventional index, PI, the correlation between MI and FEV1/FVC is -0.75+/-0.08, which substantially outperforms the correlation between PI and FEV1/FVC, i.e., -0.63+/-0.11. Moreover, we have shown that the emphysematous lesion areas constituted by small bullae balls are basically irrelevant to FEV1/FVC. The statistical analysis and special case study results show that MI can offer better assessment in different analyses.

  10. Results of testing the Grambow rate law for use in HWVP glass durability correlations

    International Nuclear Information System (INIS)

    Kuhn, W.L.; Bunnell, L.R.

    1996-03-01

    A theory based on Grambow's work on hydration of glass as linear function of solution composition was evaluated. Use of Grambow's linear rate law for correlation of durability with glass composition is not recommended. Dissolution rate of the glass was determined using the rate of release of sodium with an ion selective electrode. This method was tested first applying it to initial dissolution rate of several glasses at several temperatures with zero initial concentration of silicic acid. HW39-2, HW39-4, and SRL-202 from Savannah River were tested; there was significant scatter in the data, with the dissolution rates of HW39 glasses and the SRL glass being comparable within this scatter. The dissolution rate of SRL-202 at 80 C and pH 7 for silicic acid concentrations 0, 25, 50, and 100% saturation, was found to decrease dramatically at only 25% of the saturated silicic acid concentration, which does not conform to the linear theory

  11. A general statistical test for correlations in a finite-length time series.

    Science.gov (United States)

    Hanson, Jeffery A; Yang, Haw

    2008-06-07

    The statistical properties of the autocorrelation function from a time series composed of independently and identically distributed stochastic variables has been studied. Analytical expressions for the autocorrelation function's variance have been derived. It has been found that two common ways of calculating the autocorrelation, moving-average and Fourier transform, exhibit different uncertainty characteristics. For periodic time series, the Fourier transform method is preferred because it gives smaller uncertainties that are uniform through all time lags. Based on these analytical results, a statistically robust method has been proposed to test the existence of correlations in a time series. The statistical test is verified by computer simulations and an application to single-molecule fluorescence spectroscopy is discussed.

  12. Correlations between tests of aging in Hiroshima subjects: an attempt to define physiologic age

    Energy Technology Data Exchange (ETDEWEB)

    Hollingsworth, J W; Hashizume, Asaji; Jablon, Seymour

    1964-12-01

    Nine physiologic functions which change with age were measured in 437 subjects during their regular visits to the Atomic Bomb Casualty Commission clinic in Hiroshima, Japan. This pilot study was undertaken to determine the feasibility of collecting such data in a population sample physiologic age score. Tests conducted consisted of: skin elasticity, systolic blood pressure, vital capacity, hand grip strength, light extinction time, vibrometer, visual activity, audiometry, and serum cholesterol. The study demonstrated that adequate sample data could be obtained, and that statistical treatment could construct a physiologic age for individual subjects. However, the tests were of limited value below age 40, and the validation of the concept of physiologic age requires eventual correlation with mortality. Since the ABCC program includes a highly accurate mortality survey, it is hoped that data on physiologic aging can be collected and eventually related to mortality. 11 references, 3 figures, 6 tables.

  13. [Correlation between clinical characteristics and mycological tests in the vulvovaginitis by Candida].

    Science.gov (United States)

    Buitrón García, Rafael; Bonifaz, Alexandro; Amancio Chassin, Octavio; Basurto Kuba, Erich; Araiza, Javier; Romero Cabello, Raúl

    2007-02-01

    Vulvovaginitis caused by Candida sp is one of the most frequent infections. To culture and to identify the fungi related to clinical manifestations of patients based on a suspected diagnosis of vulvovaginal candidiasis. A prospective, transversal and comparative study was performed on 181 women older than 18 years with vulvovaginitis by Candida sp. A correlation was made between the clinical characteristics of this entity and mycological tests such as direct examination and cultures. The direct exam or fresh vaginal exam and cervical sample was positive for the different microscopic forms of Candida (blastoconidia, pseudohyphye or pseudomycelia) in 60.8% (110 women); at the same time that cultures were positive for Candida sp in 51.9% (94 patients). The direct examination and the cultures of vaginal and cervical exudate are mandatory tests for diagnosis of Candida sp in women with vulvovaginitis.

  14. Correlation of Chemical and Physical Test Data For the Environment Ageing of Coflon (PVDF). Revised

    Science.gov (United States)

    Morgan, G. J.; Campion, R. P.

    1997-01-01

    This report aims to identify correlations between mechanical property changes and chemical/morphological structure changes for Coflon. It is intended both to illustrate the overall methodology and to indicate the testing that needs to be undertaken in order to obtain correlations. Many fluid exposures have now been carried out on Coflon during the project and many data generated as a result. The report summarises the changes observed in mechanical and physical properties and relates these as well as possible to the chemistry thought to be occurring during ageing. For this purpose, data have been collated from already-issued MERL and TRI technical and progress reports. Most of the mechanical testing of aged testpieces has been performed soon after the completion of the exposure; however, there is of necessity a delay in obtaining chemical analysis of the same testpieces, so that more physical than chemical data are shown. Three fluids have so far caused measurable deterioration of Coflon, these being: methanol (Fluid A), a methanol and amine mixture (Fluid G), and a mixture of methane, carbon dioxide gas and hydrogen sulphide gas plus aqueous amine (Fluid F). Only the effects of these fluids will be dealt with in any detail in this report, although other fluids are assessed to give relevant background information. Relevant test data collated here include: tensile modulus and related properties, mode of sample failure at break, fracture toughness, fatigue crack growth rate and resistance, stress relaxation rate, permeation coefficients, % crystallinity and molecular weight distributions together with changes in fluorine levels, and other observations where appropriate. However, not all of these were obtained for every ageing condition. Because of the wide range of tests employed, and the different ways in which their results are obtained, the following section has been included to serve as a background for making comparisons.

  15. Test and Analysis Correlation for a Y-Joint Specimen for a Composite Cryotank

    Science.gov (United States)

    Mason, Brian H.; Sleight, David W.; Grenoble, Ray

    2015-01-01

    The Composite Cryotank Technology Demonstration (CCTD) project under NASA's Game Changing Development Program (GCDP) developed space technologies using advanced composite materials. Under CCTD, NASA funded the Boeing Company to design and test a number of element-level joint specimens as a precursor to a 2.4-m diameter composite cryotank. Preliminary analyses indicated that the y-joint in the cryotank had low margins of safety; hence the y-joint was considered to be a critical design region. The y-joint design includes a softening strip wedge to reduce localized shear stresses at the skirt/dome interface. In this paper, NASA-developed analytical models will be correlated with the experimental results of a series of positive-peel y-joint specimens from Boeing tests. Initial analytical models over-predicted the experimental strain gage readings in the far-field region by approximately 10%. The over-prediction was attributed to uncertainty in the elastic properties of the laminate and a mismatch between the thermal expansion of the strain gages and the laminate. The elastic properties of the analytical model were adjusted to account for the strain gage differences. The experimental strain gages also indicated a large non-linear effect in the softening strip region that was not predicted by the analytical model. This non-linear effect was attributed to delamination initiating in the softening strip region at below 20% of the failure load for the specimen. Because the specimen was contained in a thermally insulated box during cryogenic testing to failure, delamination initiation and progression was not visualized during the test. Several possible failure initiation locations were investigated, and a most likely failure scenario was determined that correlated well with the experimental data. The most likely failure scenario corresponded to damage initiating in the softening strip and delamination extending to the grips at final failure.

  16. Is a sequence of tests during urethral pressure profilometry correlated with symptoms assessment in women?

    Directory of Open Access Journals (Sweden)

    Françoise A. Valentini

    2012-12-01

    Full Text Available Introduction Our purpose was, applying a strictly defined protocol for urethral profilometry, 1 to test the repeatability of same session rest maximum urethral closure pressure (MUCP and 2 to search for correlation between women complaint and the changes in MUCP value (rest and dynamic tests. Materials and Methods A population of 140 consecutive women referred for evaluation of lower urinary tract dysfunction was stratified in 4 groups according with the urinary symptoms: stress, urge, mixed incontinence and continent and in each group in 3 age groups (young, middle age and old. The sequence of tests recorded in supine position was: urethral pressure profile at rest bladder empty, after bladder filling at 250 mL (reference test, stress profile, fatigability (before (rest and after 10 successive strong coughs, then in standing position. Results In all groups, there was no significant difference between the two MUCP values at rest bladder filled. In the three incontinent groups, MUCP was higher bladder empty than bladder filled (p < 0.05 except in the young sub-group. Stress incontinence led to significant decrease of MUCP during dynamic tests in the young group. MUCP was not modified after fatigability test in women with urge complaint whatever age. Conclusion When recorded following a strictly defined protocol, MUCP at rest bladder filled has a good repeatability in individual. However a complex sequence of tests during urethral pressure profilometry remains discussed in middle-age and old age-groups, it allows specifying the stress component of incontinence in young women and the urgency component in all age-groups.

  17. Routine blood tests are associated with short term mortality and can improve emergency department triage

    DEFF Research Database (Denmark)

    Kristensen, Michael; Iversen, Anne Kristine Servais; Gerds, Thomas Alexander

    2017-01-01

    BACKGROUND: Prioritization of acutely ill patients in the Emergency Department remains a challenge. We aimed to evaluate whether routine blood tests can predict mortality in unselected patients in an emergency department and to compare risk prediction with a formalized triage algorithm. METHODS...... registration. Multiple logistic regressions were used to predict 30-day mortality. Validation was performed by applying the regression models on the 2013 validation cohort. RESULTS: Thirty-day mortality was 5.3%. The routine blood tests had a significantly stronger discriminative value on 30-day mortality...... compared to the formalized triage (AUC 88.1 [85.7;90.5] vs. 63.4 [59.1;67.5], p blood tests was able to identify a larger number of low risk patients (n = 2100, 30-day mortality 0.1% [95% CI 0.0;0.3%]) compared to formalized triage (n = 1591, 2.8% [95% CI 2...

  18. MIDAS and HIT-6 French translation: reliability and correlation between tests.

    Science.gov (United States)

    Magnoux, E; Freeman, M A; Zlotnik, G

    2008-01-01

    The aim was to evaluate the test-retest reliability of the French translation of the Migraine Disability Assessment (MIDAS) and Headache Impact Test (HIT)-6 questionnaires as applied to episodic and chronic headaches and to assess the correlation between these two questionnaires. The MIDAS and HIT-6 questionnaires, which assess the degree of migraine-related functional disability, are widely used in headache treatment clinics. The French translation has not been checked for test-retest reliability. MIDAS involves recall, over the previous 3 months, of the number of days with functional disability with regard to work and to home and social life. HIT-6 involves a more subjective and general assessment of headache-related disability over the previous 4 weeks. We expect that there may be greater impact recall bias for chronic headaches than for episodic headaches and considered it important to be able to determine if the reliability of these questionnaires is equally good for these two patient populations. Given that both questionnaires have the same objective, that of assessing headache impact, it was thought useful to determine if their results might show a correlation and if they could thus be used interchangeably. The study was approved by an external ethics committee. The subjects were patients who regularly visit the Clinique de la Migraine de Montréal, which specializes in the treatment of headaches. The MIDAS and HIT-6 questionnaires were completed by the patients during their regular visit. Twelve days later, the same questionnaires were mailed with a prepaid return envelope. Sixty-five patients were required in both the episodic and chronic headache groups, assuming an 80% questionnaire return rate. One hundred and eighty-five patients were enrolled, and 143 completed the study, 75 with episodic headaches and 68 with chronic headaches. The questionnaire return rate was 78.9%. On average, questionnaires were completed a second time 21 days after the first

  19. RECONSTRUCTING REDSHIFT DISTRIBUTIONS WITH CROSS-CORRELATIONS: TESTS AND AN OPTIMIZED RECIPE

    International Nuclear Information System (INIS)

    Matthews, Daniel J.; Newman, Jeffrey A.

    2010-01-01

    Many of the cosmological tests to be performed by planned dark energy experiments will require extremely well-characterized photometric redshift measurements. Current estimates for cosmic shear are that the true mean redshift of the objects in each photo-z bin must be known to better than 0.002(1 + z), and the width of the bin must be known to ∼0.003(1 + z) if errors in cosmological measurements are not to be degraded significantly. A conventional approach is to calibrate these photometric redshifts with large sets of spectroscopic redshifts. However, at the depths probed by Stage III surveys (such as DES), let alone Stage IV (LSST, JDEM, and Euclid), existing large redshift samples have all been highly (25%-60%) incomplete, with a strong dependence of success rate on both redshift and galaxy properties. A powerful alternative approach is to exploit the clustering of galaxies to perform photometric redshift calibrations. Measuring the two-point angular cross-correlation between objects in some photometric redshift bin and objects with known spectroscopic redshift, as a function of the spectroscopic z, allows the true redshift distribution of a photometric sample to be reconstructed in detail, even if it includes objects too faint for spectroscopy or if spectroscopic samples are highly incomplete. We test this technique using mock DEEP2 Galaxy Redshift survey light cones constructed from the Millennium Simulation semi-analytic galaxy catalogs. From this realistic test, which incorporates the effects of galaxy bias evolution and cosmic variance, we find that the true redshift distribution of a photometric sample can, in fact, be determined accurately with cross-correlation techniques. We also compare the empirical error in the reconstruction of redshift distributions to previous analytic predictions, finding that additional components must be included in error budgets to match the simulation results. This extra error contribution is small for surveys that sample

  20. Prediction of long time creep rupture properties of welded joints using the results of short duration creep crack incubation tests

    Energy Technology Data Exchange (ETDEWEB)

    Hosseini, E.

    2013-07-01

    This dissertation submitted to the Swiss Federal Institute of Technology ETH in Zurich examines the applicability of the LICON methodology for the prediction of long-time creep rupture strength of a dissimilar metal weld. The LICON methodology is an approach for predicting the lifetime of materials under creep loading conditions. It predicts long-time uniaxial creep strength using the results from several short duration creep crack incubation tests in conjunction with the outcome of a mechanical analysis on the test-piece. This study has re-examined the previous application of the LICON methodology for 9%Cr and 1CrMoV steels. It has shown that application of the original Lion method (based on reference stress solutions) for certain materials is not appropriate. This study therefore proposes a new development for the Lion approach which uses finite-element analysis to account for the generated multiaxial stress states within welded uniaxial test-pieces.

  1. Prediction of long time creep rupture properties of welded joints using the results of short duration creep crack incubation tests

    International Nuclear Information System (INIS)

    Hosseini, E.

    2013-01-01

    This dissertation submitted to the Swiss Federal Institute of Technology ETH in Zurich examines the applicability of the LICON methodology for the prediction of long-time creep rupture strength of a dissimilar metal weld. The LICON methodology is an approach for predicting the lifetime of materials under creep loading conditions. It predicts long-time uniaxial creep strength using the results from several short duration creep crack incubation tests in conjunction with the outcome of a mechanical analysis on the test-piece. This study has re-examined the previous application of the LICON methodology for 9%Cr and 1CrMoV steels. It has shown that application of the original Lion method (based on reference stress solutions) for certain materials is not appropriate. This study therefore proposes a new development for the Lion approach which uses finite-element analysis to account for the generated multiaxial stress states within welded uniaxial test-pieces

  2. Study on the Correlation between PSR and Korean Stress Test for Continued Operation of Aging NPP

    International Nuclear Information System (INIS)

    Chung, June Ho; Kim, Tae Ryong

    2013-01-01

    acceptance. Therefore, it is highly recommended and necessary to include the Korean Stress Test into the regulation system of CO evaluation. In that event, it is advisable that the related guidelines and regulations should be revised based on the updated IAEA PSR guideline. The correlation of assessment items between the PSR and the Korean Stress Test should also be reflected in the revision

  3. Development and testing of an innovative short-term large wind ramp forecasting system

    Energy Technology Data Exchange (ETDEWEB)

    Zack, J.W. [AWS Truepower LLC, Troy, NY (United States)

    2010-07-01

    This PowerPoint presentation discussed a ramp forecasting tool designed for use in a region of Texas with a high wind-generating capacity. Large system-wide ramps frequently occur in the region, and curtailments are common due to transmission constraints. The average hourly load of the power system is 32,101 MW. Wind power capacity in the region is 9382 MW. However, actual production rarely exceeds 6500 MW due to the curtailments. The short-term ramp forecasting tool was designed to aid in grid management decisions for the 0-6 hour ahead period as well as to address issues related to wind farm time series data and the lack of situational awareness information. The tool provided rapid updates for grid point wind analysis with feature detection and tracking algorithms and a rapid update cycle model. The tool also featured a suite of web-based applications that included deterministic ramp even forecasts, power production time series forecasts, and situational awareness products that are updated every 15 minutes. A performance evaluation study of the tool was provided. tabs., figs.

  4. Facial averageness and genetic quality: Testing heritability, genetic correlation with attractiveness, and the paternal age effect.

    Science.gov (United States)

    Lee, Anthony J; Mitchem, Dorian G; Wright, Margaret J; Martin, Nicholas G; Keller, Matthew C; Zietsch, Brendan P

    2016-01-01

    Popular theory suggests that facial averageness is preferred in a partner for genetic benefits to offspring. However, whether facial averageness is associated with genetic quality is yet to be established. Here, we computed an objective measure of facial averageness for a large sample ( N = 1,823) of identical and nonidentical twins and their siblings to test two predictions from the theory that facial averageness reflects genetic quality. First, we use biometrical modelling to estimate the heritability of facial averageness, which is necessary if it reflects genetic quality. We also test for a genetic association between facial averageness and facial attractiveness. Second, we assess whether paternal age at conception (a proxy of mutation load) is associated with facial averageness and facial attractiveness. Our findings are mixed with respect to our hypotheses. While we found that facial averageness does have a genetic component, and a significant phenotypic correlation exists between facial averageness and attractiveness, we did not find a genetic correlation between facial averageness and attractiveness (therefore, we cannot say that the genes that affect facial averageness also affect facial attractiveness) and paternal age at conception was not negatively associated with facial averageness. These findings support some of the previously untested assumptions of the 'genetic benefits' account of facial averageness, but cast doubt on others.

  5. Correlation of Chemical and Physical Test Data for the Environmental Ageing of Tefzel (ETFE)

    Science.gov (United States)

    Morgan, G. J.; Campion, R. P.

    1996-01-01

    In a similar approach to that used for the previously issued correlation report for Coflon (CAPP/M.10), this report aims to identify any correlations between mechanical property changes and chemical/morphological changes for Tefzel, using information supplied in other MERL and TRI project reports (plus latest data which will be included in final reports for Phase 1). Differences identified with Coflon behaviour will be of scientific interest as well as appropriate to project applications, as Tefzel and Coflon are chemical isomers. Owing to the considerable chemical resistance of Tefzel, much of its testing so far has been based on mechanical properties. Where changes have occurred, chemical analysis can now be targeted more effectively. Relevant test data collated here include: tensile modulus and related properties, permeation coefficients, % crystallinity, and other observations where significant. Fluids based on methanol and amine (Fluid G), a mixture of methane, carbon dioxide and hydrogen sulphide gases plus an aqueous amine solution (Fluid F), and an aromatic oil mix of heptane, cyclohexane, toluene and I-propanol (Fluid 1) have affected Tefzel to varying degrees, and are discussed in some detail herein.

  6. Correlation of Chemical and Physical Test Data for the Environmental Ageing of Tefzel (ETFE). Revised

    Science.gov (United States)

    Morgan, G. J.; Campion, R. P.

    1997-01-01

    In a similar approach to that used for the previously issued correlation report for Coflon (CAPP/M.10), this report aims to identify any correlations between mechanical property changes and chemical/morphological changes for Tefzel, using information supplied in other MERL and TRI project reports. Differences identified with Coflon behaviour will be of scientific interest as well as appropriate to project applications, as Tefzel and Coflon are chemical isomers. Owing to the considerable chemical resistance of Tefzel, much of its testing so far has been based on mechanical properties. Where changes have occurred, chemical analysis can now be targeted more effectively. Relevant test data collated here include: tensile modulus and related properties, permeation coefficients, % crystallinity, some crack growth resistance measurements, and other observations where significant. Fluids based on methanol and amine (Fluid G), a mixture of methane, carbon dioxide and hydrogen sulphide gases plus an aqueous amine solution (Fluid F), and an aromatic oil mix of heptane, cyclohexane, toluene and 1-propanol (Fluid I) have affected Tefzel to varying degrees, and are discussed in some detail herein.

  7. Thin-section CT imaging that correlates with pulmonary function tests in obstructive airway disease

    Energy Technology Data Exchange (ETDEWEB)

    Arakawa, Hiroaki, E-mail: arakawa@dokkyomed.ac.jp [Department of Radiology, Dokkyo Medical University, 880 Kita-Kobayashi, Mibu, Tochigi 321-0293 (Japan); Fujimoto, Kiminori [Department of Radiology, Kurume University School of Medicine (Japan); Fukushima, Yasutugu [Department of Pulmonary Medicine and Clinical Immunology, Dokkyo Medical University (Japan); Kaji, Yasushi [Department of Radiology, Dokkyo Medical University, 880 Kita-Kobayashi, Mibu, Tochigi 321-0293 (Japan)

    2011-11-15

    Purpose: The purpose of this study was to identify independent CT findings that correlated with pulmonary function tests (PFTs) in patients with obstructive airway diseases. Materials and methods: Sixty-eight patients with obstructive airway disease and 29 normal subjects (mean age, 52 years; 36 men and 61 women) underwent inspiratory and expiratory thin-section CT and PFTs. Patient with obvious emphysema was excluded. Two radiologists independently reviewed the images and semi-quantitatively evaluated lung attenuation (mosaic perfusion, air trapping) and airway abnormalities (extent and severity of bronchial wall thickening and bronchiectasis, bronchiolectasis or centrilobular nodules, mucous plugging). Univariate, multivariate and receiver operating characteristic (ROC) analyses were performed with CT findings and PFTs. Results: Forty-two patients showed obstructive PFTs, 26 symptomatic patients showed near-normal PFTs. On univariate analysis, air trapping and bronchial wall thickening showed highest correlation with obstructive PFTs such as FEV1.0/FVC, MMEF and FEF75 (r ranged from -0.712 to -0.782; p < 0.001), while mosaic perfusion and mucous plugging showed moderate correlation, and bronchiectasis, bronchiolectasis and nodules showed the least, but significant, correlation. Multiple logistic analyses revealed air trapping and bronchial wall thickening as the only significant independent determinants of obstructive PFTs. ROC analysis revealed the cut-off value of air trapping for obstructive PFTs to be one-third of whole lung (area under curve, 0.847). Conclusions: Our study confirmed air trapping and bronchial wall thickening are the most important observations when imaging obstructive PFTs. The cut-off value of air trapping for identifying obstructive PFTs was one-third of lung irrespective of inspiratory CT findings.

  8. Tracheal morphology and collapse in COPD: Correlation with CT indices and pulmonary function test

    International Nuclear Information System (INIS)

    Lee, Hyun Joo; Seo, Joon Beom; Chae, Eun Jin; Kim, Namkug; Lee, Choong Wook; Oh, Yeon-Mok; Lee, Sang Do

    2011-01-01

    Objectives: To assess the tracheal morphologic changes using CT in COPD (chronic obstructive lung disease) patients and to assess correlation between them and PFT (pulmonary function test) and CT parameters. Materials and methods: Ninety-two healthy individuals and 115 patients with COPD who underwent volumetric inspiration/expiration CT scanning were included. The Lsag, Lcor, and the tLA were measured. The TI was defined as the ratio of Lcor/Lsag. The tracheal morphologic changes (tLA, TI, and collapsibility) were compared in healthy individuals and COPD. In COPD patients, correlation of the tracheal morphologic change with PFT and CT parameters was assessed. Results: The TIs in the COPD patients were significantly lower than those in the control group (0.80 ± 0.15 vs. 0.88 ± 0.11, Mean ± SD) (p 1 (r = 0.29, p = 1 /FVC (r = 0.26, p < 0.01), and the GOLD stage (r = −0.26, p < 0.01). TI showed significant correlation with EI on both inspiration and expiration CT (r = −0.19, p = 0.04 and r = −0.23, p = 0.02), MLD on expiration CT (r = 0.27, p < 0.01), CT–ATI (r = 0.34, p < 0.01), and with LV on expiration CT (r = −0.25, p < 0.01). Conclusion: Among the tracheal morphologic changes, the most significant change in COPD patients compared with that in the control group, was the TI. In COPD patients, the tracheal morphologic change showed clinically significant correlation with severity of emphysema and CT indices.

  9. The use of standardised short-term and working memory tests in aphasia research: a systematic review.

    Science.gov (United States)

    Murray, Laura; Salis, Christos; Martin, Nadine; Dralle, Jenny

    2018-04-01

    Impairments of short-term and working memory (STM, WM), both verbal and non-verbal, are ubiquitous in aphasia. Increasing interest in assessing STM and WM in aphasia research and clinical practice as well as a growing evidence base of STM/WM treatments for aphasia warrant an understanding of the range of standardised STM/WM measures that have been utilised in aphasia. To date, however, no previous systematic review has focused on aphasia. Accordingly, the goals of this systematic review were: (1) to identify standardised tests of STM and WM utilised in the aphasia literature, (2) to evaluate critically the psychometric strength of these tests, and (3) to appraise critically the quality of the investigations utilising these tests. Results revealed that a very limited number of standardised tests, in the verbal and non-verbal domains, had robust psychometric properties. Standardisation samples to elicit normative data were often small, and most measures exhibited poor validity and reliability properties. Studies using these tests inconsistently documented demographic and aphasia variables essential to interpreting STM/WM test outcomes. In light of these findings, recommendations are provided to foster, in the future, consistency across aphasia studies and confidence in STM/WM tests as assessment and treatment outcome measures.

  10. Measuring Attending Behavior and Short-Term Memory with Knox's Cube Test.

    Science.gov (United States)

    Stone, Mark H.; Wright, Benjamin D.

    1983-01-01

    A new revision was developed using Rasch psychometric techniques to build a Knox's Cube Test (KCT) variable and item bank using the tapping series from all previous editions. The report forms developed give a clear picture of the subject's performance set in a context that is both normative and criterion. (Author/BW)

  11. Short term creep small punch testing of P91 and P92 steels,

    Czech Academy of Sciences Publication Activity Database

    Dymáček, Petr

    2011-01-01

    Roč. 465, - (2011), s. 179-182 ISSN 1013-9826. [Materials Structure & Micromechanics of Fracture 6. Brno, 28.6.2010-30.6,2010] R&D Projects: GA AV ČR(CZ) IAA200410801 Institutional research plan: CEZ:AV0Z20410507 Keywords : creep * small punch test * chromium steel Subject RIV: JG - Metallurgy

  12. A Short Submaximal test to determine the fatigue threshold of knee extensors in young men

    NARCIS (Netherlands)

    de Ruiter, C.J.; Hamacher, P.; Wolfs, B.G.A.

    Purpose Recently, a fatigue threshold obtained during submaximal repetitive isometric knee extensor contractions was related to VO 2max measured during cycling and to exercise endurance. However, test duration is quite long (20-30 min in young people) to be of practical and possibly clinical use.

  13. HBA1C AND MEAN GLUCOSE DERIVED FROM SHORT-TERM CONTINUOUS GLUCOSE MONITORING ASSESSMENT DO NOT CORRELATE IN PATIENTS WITH HBA1C >8.

    Science.gov (United States)

    Yamada, Eijiro; Okada, Shuichi; Nakajima, Yasuyo; Bastie, Claire C; Vatish, Manu; Tagaya, Yuko; Osaki, Aya; Shimoda, Yoko; Shibusawa, Ryo; Saito, Tsugumichi; Okamura, Takashi; Ozawa, Atsushi; Yamada, Masanobu

    2017-01-01

    Optimum therapy for patients with diabetes depends on both acute and long-term changes in plasma glucose, generally assessed by glycated hemoglobin (HbA1c) levels. However, the correlation between HbA1c and circulating glucose has not been fully determined. Therefore, we carefully examined this correlation when glucose levels were assessed by continuous glucose monitoring (CGM). Fifty-one patients (70% female, 30% male) were examined; among them were 28 with type 1 diabetes and 23 with type 2 diabetes. Clinically determined HbA1c levels were compared with blood glucose determined by CGM during a short time period. Changes in HbA1c levels up to 8.0% showed a clear and statistically strong correlation (R = 0.6713; PHbA1c and CGM-assessed glucose levels in our patient population when HbA1c was >8.0%. Short-term CGM appears to be a good clinical indicator of long-term glucose control (HbA1c levels); however, cautions should be taken while interpreting CGM data from patients with HbA1c levels >8.0%. Over- or underestimation of the actual mean glucose from CGM data could potentially increase the risks of inappropriate treatment. As such, our results indicate that a more accurate analysis of CGM data might be useful to adequately tailor clinical treatments. ADAG = A1c-Derived Average Glucose CGM = continuous glucose monitoring %CV = percent coefficient of variation HbA1c = glycated hemoglobin.

  14. Field tests and machine learning approaches for refining algorithms and correlations of driver's model parameters.

    Science.gov (United States)

    Tango, Fabio; Minin, Luca; Tesauri, Francesco; Montanari, Roberto

    2010-03-01

    This paper describes the field tests on a driving simulator carried out to validate the algorithms and the correlations of dynamic parameters, specifically driving task demand and drivers' distraction, able to predict drivers' intentions. These parameters belong to the driver's model developed by AIDE (Adaptive Integrated Driver-vehicle InterfacE) European Integrated Project. Drivers' behavioural data have been collected from the simulator tests to model and validate these parameters using machine learning techniques, specifically the adaptive neuro fuzzy inference systems (ANFIS) and the artificial neural network (ANN). Two models of task demand and distraction have been developed, one for each adopted technique. The paper provides an overview of the driver's model, the description of the task demand and distraction modelling and the tests conducted for the validation of these parameters. A test comparing predicted and expected outcomes of the modelled parameters for each machine learning technique has been carried out: for distraction, in particular, promising results (low prediction errors) have been obtained by adopting an artificial neural network.

  15. Nonlinear Analysis and Post-Test Correlation for a Curved PRSEUS Panel

    Science.gov (United States)

    Gould, Kevin; Lovejoy, Andrew E.; Jegley, Dawn; Neal, Albert L.; Linton, Kim, A.; Bergan, Andrew C.; Bakuckas, John G., Jr.

    2013-01-01

    The Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) concept, developed by The Boeing Company, has been extensively studied as part of the National Aeronautics and Space Administration's (NASA s) Environmentally Responsible Aviation (ERA) Program. The PRSEUS concept provides a light-weight alternative to aluminum or traditional composite design concepts and is applicable to traditional-shaped fuselage barrels and wings, as well as advanced configurations such as a hybrid wing body or truss braced wings. Therefore, NASA, the Federal Aviation Administration (FAA) and The Boeing Company partnered in an effort to assess the performance and damage arrestments capabilities of a PRSEUS concept panel using a full-scale curved panel in the FAA Full-Scale Aircraft Structural Test Evaluation and Research (FASTER) facility. Testing was conducted in the FASTER facility by subjecting the panel to axial tension loads applied to the ends of the panel, internal pressure, and combined axial tension and internal pressure loadings. Additionally, reactive hoop loads were applied to the skin and frames of the panel along its edges. The panel successfully supported the required design loads in the pristine condition and with a severed stiffener. The panel also demonstrated that the PRSEUS concept could arrest the progression of damage including crack arrestment and crack turning. This paper presents the nonlinear post-test analysis and correlation with test results for the curved PRSEUS panel. It is shown that nonlinear analysis can accurately calculate the behavior of a PRSEUS panel under tension, pressure and combined loading conditions.

  16. Application of rat mast cell incubates as a possible short-time test for sensitizing occupational chemicals

    Energy Technology Data Exchange (ETDEWEB)

    Diel, F.; Neidhart, B.; Opree, W.

    1981-08-01

    The direct action of sensitizing occupational chemicals (formaldehyde, phenol, phenylhydrazine, p-aminophenol) on rat mast cells was investigated by determination of histamine using HPLC separation and fluorimetric detection. It turned out that dispersed mast cells from immunized and non-immunized Wistar-rats are more sensitive than small-cut lung tissue slices. Passive cutaneous anaphylaxis was negative after a fortnight sensitizing experiment with the here described occupational chemicals. Short-time tests with rat mast cells reflect anaphylactoid response and are suitable for the screening of sensitizing chemicals.

  17. Automated collimation testing by determining the statistical correlation coefficient of Talbot self-images.

    Science.gov (United States)

    Rana, Santosh; Dhanotia, Jitendra; Bhatia, Vimal; Prakash, Shashi

    2018-04-01

    In this paper, we propose a simple, fast, and accurate technique for detection of collimation position of an optical beam using the self-imaging phenomenon and correlation analysis. Herrera-Fernandez et al. [J. Opt.18, 075608 (2016)JOOPDB0150-536X10.1088/2040-8978/18/7/075608] proposed an experimental arrangement for collimation testing by comparing the period of two different self-images produced by a single diffraction grating. Following their approach, we propose a testing procedure based on correlation coefficient (CC) for efficient detection of variation in the size and fringe width of the Talbot self-images and thereby the collimation position. When the beam is collimated, the physical properties of the self-images of the grating, such as its size and fringe width, do not vary from one Talbot plane to the other and are identical; the CC is maximum in such a situation. For the de-collimated position, the size and fringe width of the self-images vary, and correspondingly the CC decreases. Hence, the magnitude of CC is a measure of degree of collimation. Using the method, we could set the collimation position to a resolution of 1 μm, which relates to ±0.25   μ    radians in terms of collimation angle (for testing a collimating lens of diameter 46 mm and focal length 300 mm). In contrast to most collimation techniques reported to date, the proposed technique does not require a translation/rotation of the grating, use of complicated phase evaluation algorithms, or an intricate method for determination of period of the grating or its self-images. The technique is fully automated and provides high resolution and precision.

  18. The glucagon test in the diagnosis of growth hormone deficiency in children with short stature younger than 6 years.

    Science.gov (United States)

    Secco, Andrea; di Iorgi, Natascia; Napoli, Flavia; Calandra, Erika; Ghezzi, Michele; Frassinetti, Costanza; Parodi, Stefano; Casini, Maria Rosaria; Lorini, Renata; Loche, Sandro; Maghnie, Mohamad

    2009-11-01

    Few studies have addressed the diagnostic role of the glucagon test in children with suspected GH deficiency (GHD). The objective of the study was to investigate the diagnostic value of the glucagon test as an alternative test to insulin tolerance test (ITT) and arginine in GHD children younger than 6 yr. This study was conducted in two pediatric endocrinology centers. Forty-eight children (median age 4.2 yr, median height -3.0 sd score) with GHD confirmed by a peak GH to ITT and arginine less than 10 microg/liter (median 4.7 and 3.4 microg/liter, respectively) underwent a glucagon stimulation test. Magnetic resonance imaging showed normal hypothalamic-pituitary anatomy in 24 children, isolated anterior pituitary hypoplasia in seven, and structural hypothalamic-pituitary abnormalities in 17. Median GH peak response to glucagon (13.5 microg/liter) was significantly higher than that observed after ITT and arginine (P short stature. Normative data for this test in young children need to be established before its use in clinical practice.

  19. Definition of the applicability domain of the Short Time Exposure (STE) test for predicting the eye irritation of chemicals.

    Science.gov (United States)

    Hayashi, Kazuhiko; Abo, Takayuki; Nukada, Yuko; Sakaguchi, Hitoshi

    2013-05-01

    The Short Time Exposure (STE) test is a simple and easy-to-perform in vitro eye irritation test, that uses the viability of SIRC cells (a rabbit corneal cell line) treated for five minutes as the endpoint. In this study, our goal was to define the applicability domain of the STE test, based on the results obtained with a set of 113 substances. To achieve this goal, chemicals were selected to represent both different chemical classes and different chemical properties, as well as to cover, in a balanced manner, the categories of eye irritation potential according to the Globally Harmonised System (GHS). Accuracy analysis indicated that the rates of false negatives for organic/inorganic salts (75.0%), hydrocarbons (33.3%) and alcohols (23.5%) were high. Many of the false negative results were for solid substances. It is noteworthy that no surfactant resulted in a false negative result in the STE test. Further examination of the physical property data and performance showed a significant improvement in the predictive accuracy, when substances with vapour pressures over 6kPa were excluded from the analyses. Our results indicate that several substances - i.e. certain solids such as salts, alcohols, hydrocarbons, and volatile substances with a vapour pressure over 6kPa - do not fall within the applicability domain of the STE test. Overall, we are encouraged by the performance and improved accuracy of the STE test. 2013 FRAME.

  20. Quantitative CT analysis of honeycombing area in idiopathic pulmonary fibrosis: Correlations with pulmonary function tests.

    Science.gov (United States)

    Nakagawa, Hiroaki; Nagatani, Yukihiro; Takahashi, Masashi; Ogawa, Emiko; Tho, Nguyen Van; Ryujin, Yasushi; Nagao, Taishi; Nakano, Yasutaka

    2016-01-01

    The 2011 official statement of idiopathic pulmonary fibrosis (IPF) mentions that the extent of honeycombing and the worsening of fibrosis on high-resolution computed tomography (HRCT) in IPF are associated with the increased risk of mortality. However, there are few reports about the quantitative computed tomography (CT) analysis of honeycombing area. In this study, we first proposed a computer-aided method for quantitative CT analysis of honeycombing area in patients with IPF. We then evaluated the correlations between honeycombing area measured by the proposed method with that estimated by radiologists or with parameters of PFTs. Chest HRCTs and pulmonary function tests (PFTs) of 36 IPF patients, who were diagnosed using HRCT alone, were retrospectively evaluated. Two thoracic radiologists independently estimated the honeycombing area as Identified Area (IA) and the percentage of honeycombing area to total lung area as Percent Area (PA) on 3 axial CT slices for each patient. We also developed a computer-aided method to measure the honeycombing area on CT images of those patients. The total honeycombing area as CT honeycombing area (HA) and the percentage of honeycombing area to total lung area as CT %honeycombing area (%HA) were derived from the computer-aided method for each patient. HA derived from three CT slices was significantly correlated with IA (ρ=0.65 for Radiologist 1 and ρ=0.68 for Radiologist 2). %HA derived from three CT slices was also significantly correlated with PA (ρ=0.68 for Radiologist 1 and ρ=0.70 for Radiologist 2). HA and %HA derived from all CT slices were significantly correlated with FVC (%pred.), DLCO (%pred.), and the composite physiologic index (CPI) (HA: ρ=-0.43, ρ=-0.56, ρ=0.63 and %HA: ρ=-0.60, ρ=-0.49, ρ=0.69, respectively). The honeycombing area measured by the proposed computer-aided method was correlated with that estimated by expert radiologists and with parameters of PFTs. This quantitative CT analysis of

  1. Correlation of the New York Heart Association classification and the cardiopulmonary exercise test: A systematic review.

    Science.gov (United States)

    Lim, Fang Yi; Yap, Jonathan; Gao, Fei; Teo, Ling Li; Lam, Carolyn S P; Yeo, Khung Keong

    2018-07-15

    The New York Heart Association (NYHA) classification is frequently used in the management of heart failure but may be limited by patient and physician subjectivity. Cardiopulmonary exercise testing (CPET) provides a potentially more objective measurement of functional status. We aim to study the correlation between NYHA classification and peak oxygen consumption (pVO 2 ) on Cardiopulmonary Exercise Testing (CPET) within and across published studies. A systematic literature review on all studies reporting both NYHA class and CPET data was performed, and pVO 2 from CPET was correlated to reported NYHA class within and across eligible studies. 38 studies involving 2645 patients were eligible. Heterogenity was assessed by the Q statistic, which is a χ2 test and marker of systematic differences between studies. Within each NYHA class, significant heterogeneity in pVO 2 was seen across studies: NYHA I (n = 17, Q = 486.7, p < 0.0001), II (n = 24, Q = 381.0, p < 0.0001), III (n = 32, Q = 761.3, p < 0.0001) and IV (n = 5, Q = 12.8, p = 0.012). Significant differences in mean pVO 2 were observed between NYHA I and II (23.8 vs 17.6 mL/(kg·min), p < 0.0001) and II and III (17.6 vs 13.3 mL/(kg·min), p < 0.0001); but not between NYHA III and IV (13.3 vs 12.5 mL/(kg·min), p = 0.45). These differences remained significant after adjusting for age, gender, ejection fraction and region of study. There was a general inverse correlation between NYHA class and pVO 2. However, significant heterogeneity in pVO 2 exists across studies within each NYHA class. While the NYHA classification holds clinical value in heart failure management, direct comparison across studies may have its limitations. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Correlation between audiovestibular function tests and hearing outcomes in severe to profound sudden sensorineural hearing loss.

    Science.gov (United States)

    Wang, Chi-Te; Huang, Tsung-Wei; Kuo, Shih-Wei; Cheng, Po-Wen

    2009-02-01

    This study investigated whether audiovestibular function tests, namely auditory brain stem response (ABR) and vestibular-evoked myogenic potential (VEMP) tests were correlated to hearing outcomes after controlling the effects of other potential confounding factors in severe to profound sudden sensorineural hearing loss (SSHL). Eighty-eight patients with severe to profound SSHL were enrolled in this study. Pretreatment hearing levels, results of audiovestibular function tests, and final hearing outcomes were recorded from retrospective chart reviews. Other factors, including age, gender, delay of treatment, vertigo, diabetes mellitus, and hypertension, were collected as well. Comparative analysis between multiple variables and hearing outcomes was conducted using the cumulative logits model in overall subjects. Further, multivariate analysis of prognostic factors was conducted in the stratified groups of severe (70 dB HL 90 dB HL) SSHL. Multivariate analysis showed that pretreatment hearing levels, presence of vertigo, and results of ABR and VEMP testing were significant outcome predictors in the overall subjects. Stratification analysis demonstrated that both the presence of ABR and VEMP waveforms were significantly correlated with better hearing outcomes in the group of severe SSHL [ABR: adjusted odds ratio (aOR) = 14.7, 95% confidence interval (CI) = 1.78 to 122, p = 0.01; VEMP: aOR = 5.91, 95% CI = 1.18 to 29.5, p = 0.03], whereas the presence of vertigo was the only significant negative prognostic factor in the group of profound SSHL (aOR = 0.24, 95% CI = 0.06 to 0.95, p = 0.04). Other variables, including age, gender, diabetes mellitus, hypertension, and delay of treatment, were not significantly related to hearing outcomes in both groups (p > 0.05). A predictive hearing recovery table with the combined ABR and VEMP results was proposed for the group of severe SSHL. ABR and VEMP tests should be included in the battery of neurootological examinations in

  3. Short communication: Correlation between within-herd antibody-prevalence and bulk tank milk antibody levels to Mycobacterium avium ssp. paratuberculosis using 2 commercial immunoassays.

    Science.gov (United States)

    Pesqueira, M N; Yus, E; Factor, C; Mato, I; Sanjuán, M L; Eiras, C; Arnaiz, I; Diéguez, F J

    2017-09-01

    The objective of this study was to determine the correlation between the results obtained with the ELISA technique for antibodies to Mycobacterium avium ssp. paratuberculosis in serum and bulk tank milk at the herd level. For this purpose, 203 samples of bulk tank milk were analyzed with 2 commercial ELISA from dairy herds with a prevalence of seropositive animals that was also determined. In regard to the reference test (results in blood serum), the sensitivity of the bulk tank milk test to detect high-positive herds (≥10% seroprevalence) ranged from 85.7 to 71.4%. The specificity to detect herds with no seropositive animals ranged from 70.5 to 53%. In a quantitative approach, Pearson correlation coefficients, reported as a measure of the linear association between herd seroprevalences and transformed optical density values recorded in bulk tank milk, were 0.39 and 0.54 for the studied ELISA. Although the test results were relatively fairly correlated with the within-herd prevalence, the practical utility of bulk tank milk testing for Mycobacterium avium ssp. paratuberculosis seems limited, especially regarding specificity. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  4. Graph Theoretical Analysis of Functional Brain Networks: Test-Retest Evaluation on Short- and Long-Term Resting-State Functional MRI Data

    Science.gov (United States)

    Wang, Jin-Hui; Zuo, Xi-Nian; Gohel, Suril; Milham, Michael P.; Biswal, Bharat B.; He, Yong

    2011-01-01

    Graph-based computational network analysis has proven a powerful tool to quantitatively characterize functional architectures of the brain. However, the test-retest (TRT) reliability of graph metrics of functional networks has not been systematically examined. Here, we investigated TRT reliability of topological metrics of functional brain networks derived from resting-state functional magnetic resonance imaging data. Specifically, we evaluated both short-term (5 months apart) TRT reliability for 12 global and 6 local nodal network metrics. We found that reliability of global network metrics was overall low, threshold-sensitive and dependent on several factors of scanning time interval (TI, long-term>short-term), network membership (NM, networks excluding negative correlations>networks including negative correlations) and network type (NT, binarized networks>weighted networks). The dependence was modulated by another factor of node definition (ND) strategy. The local nodal reliability exhibited large variability across nodal metrics and a spatially heterogeneous distribution. Nodal degree was the most reliable metric and varied the least across the factors above. Hub regions in association and limbic/paralimbic cortices showed moderate TRT reliability. Importantly, nodal reliability was robust to above-mentioned four factors. Simulation analysis revealed that global network metrics were extremely sensitive (but varying degrees) to noise in functional connectivity and weighted networks generated numerically more reliable results in compared with binarized networks. For nodal network metrics, they showed high resistance to noise in functional connectivity and no NT related differences were found in the resistance. These findings provide important implications on how to choose reliable analytical schemes and network metrics of interest. PMID:21818285

  5. Correlation between Stress Hyperglycemia and Short-Term Prognosis in non Diabetic Patients with Acute Myocardial Infarction

    Directory of Open Access Journals (Sweden)

    Rafighdoust Amirhossein

    2009-03-01

    Full Text Available Background: Abnormal hyperglycemia is a common finding in early phase of acute myocardial infarction that is named as stress hyperglycemia. In this study we have evaluated primary blood sugar of non-diabetic patients with acute myocardial infarction at the time of admission to compare the early complications between patients with high or normal blood sugar. We aimed to find any relation between primary blood sugar and post MI complication rate. Materials and Methods: One hundred non-diabetic patients with acute myocardial infarction who were referred to heart emergency ward of Imam Reza Hospital (Mashhad, Iran were included in this study. According to primary blood glucose level, 50 patients with blood glucose > 126 mg/dl were compared with 50 patients with normal blood glucose level. All patients were evaluated during hospitalization and daily clinical examinations laboratory tests, and routine non-invasive assessments were done. The results were analyzed by SPSS software and the level of signification difference was described as p<0.05.Results: Sinus tachycardia, atrial fibrillation, bundle branch block, ventricular extrasystole, prolonged PR-interval and heart failure according to Klip classification and also according to echocardiographic index (EF<50 were statistically significant and more common in hyperglycemic patients (P<0.05. Thromboembolic and mechanical complications (papillary muscle dysfunction, pericarditis, phlebitis and angina were also more common in hyperglycemic group although the differences were not significant statistically. Conclusion: It seems that high rate of early complications in non-diabetic patients with acute myocardial infarction is directly related to primary hyperglycemia (stress hyperglycemia.

  6. SUSCEPTIBILITY TEST FOR FUNGI: CLINICAL AND LABORATORIAL CORRELATIONS IN MEDICAL MYCOLOGY

    Directory of Open Access Journals (Sweden)

    Ana ALASTRUEY-IZQUIERDO

    2015-09-01

    Full Text Available SUMMARYDuring recent decades, antifungal susceptibility testing has become standardized and nowadays has the same role of the antibacterial susceptibility testing in microbiology laboratories. American and European standards have been developed, as well as equivalent commercial systems which are more appropriate for clinical laboratories. The detection of resistant strains by means of these systems has allowed the study and understanding of the molecular basis and the mechanisms of resistance of fungal species to antifungal agents. In addition, many studies on the correlation of in vitro results with the outcome of patients have been performed, reaching the conclusion that infections caused by resistant strains have worse outcome than those caused by susceptible fungal isolates. These studies have allowed the development of interpretative breakpoints for Candida spp. and Aspergillus spp., the most frequent agents of fungal infections in the world. In summary, antifungal susceptibility tests have become essential tools to guide the treatment of fungal diseases, to know the local and global disease epidemiology, and to identify resistance to antifungals.

  7. Investigating the correlation between wastewater analysis and roadside drug testing in South Australia.

    Science.gov (United States)

    Bade, Richard; Tscharke, Benjamin J; Longo, Marie; Cooke, Richard; White, Jason M; Gerber, Cobus

    2018-04-10

    The societal impact of drug use is well known. An example is when drug-intoxicated drivers increase the burden on policing and healthcare services. This work presents the correlation of wastewater analysis (using UHPLC-MS/MS) and positive roadside drug testing results for methamphetamine, 3,4-methylenedioxymethamphetamine (MDMA) and cannabis from December 2011-December 2016 in South Australia. Methamphetamine and MDMA showed similar trends between the data sources with matching increases and decreases, respectively. Cannabis was relatively steady based on wastewater analysis, but the roadside drug testing data started to diverge in the final part of the measurement period. The ability to triangulate data as shown here validates both wastewater analysis and roadside drug testing. This suggests that changes in overall population drug use revealed by WWA is consistent and proportional with changes in drug-driving behaviours. The results show that, at higher levels of drug use as measured by wastewater analysis, there is an increase in drug driving in the community and therefore more strain on health services and police. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Characterization of zinc alloy by sheet bulging test with analytical models and digital image correlation

    Science.gov (United States)

    Vitu, L.; Laforge, N.; Malécot, P.; Boudeau, N.; Manov, S.; Milesi, M.

    2018-05-01

    Zinc alloys are used in a wide range of application such as electronics, automotive and building construction. Their various shapes are generally obtained by metal forming operation such as stamping. Therefore, it is important to characterize the material with adequate characterization tests. Sheet Bulging Test (SBT) is well recognized in the metal forming community. Different theoretical models of the literature for the evaluation of thickness and radius of the deformed sheet in SBT have been studied in order to get the hardening curve of different materials. These theoretical models present the advantage that the experimental procedure is very simple. But Koç et al. showed their limitation, since the combination of thickness and radius evaluations depend on the material. As Zinc alloys are strongly anisotropic with a special crystalline structure, a procedure is adopted for characterizing the hardening curve of a Zinc alloy. The anisotropy is first studied with tensile test, and SBT with elliptical dies is also investigated. Parallel to this, Digital Image Correlation (DIC) measures are carried out. The results obtained from theoretical models and DIC measures are compared. Measures done on post-mortem specimens complete the comparisons. Finally, DIC measures give better results and the resulting hardening curve of the studied zinc alloy is provided.

  9. Safe affordable fission engine (SAFE 30) module conductivity test thermal model correlation

    International Nuclear Information System (INIS)

    Roman, Jose

    2001-01-01

    The SAFE 30 is a simple, robust space fission power system that is comprised of several independent modules. Each module contains 4 fuel tubes bonded to a central heatpipe. Fission energy is conducted from the fuel tubes to the heatpipe, which in turn transfers the energy to a power conversion system. This paper benchmarks a thermal model of the SAFE 30 with actual test data from simulated SAFE 30 module tests. Two 'dummy' SAFE 30 modules were fabricated - each consisted of 4 1-inch dia. tubes (simulating the fuel tubes) bonded to a central '1' dia. tube (simulating the heatpipe). In the first module the fuel tubes were simply brazed to the heatpipe along the line of contact (leaving void space in the interstices), and in the second module the tubes and heatpipe were brazed via tri-cusps that completely fill the interstices between the tubes. In these tests, fission energy is simulated by placing resistance heaters within each of the 4 fuel tubes. The tests were conducted in a vacuum chamber in 4 configurations: tri-cusps filled with and without an outer insulation wrap, and no tri-cusps with and without an outer insulation wrap. The baseline SAFE 30 configuration uses the brazed tri-cusps. During the tests, the power applied to the heaters was varied in a stepwise fashion, until a steady-state temperature profile was reached. These temperature levels varied between 773 K and 1073 K. To benchmark the thermal model, the input energy and chamber surface temperature were used as boundary conditions for the model. The analytical results from the nodes at the same location as the test thermocouples were plotted again test data to determinate the accuracy of the analysis. The unknown variables on the analysis are the radiation emissivity of the pipe and chamber and the radiation view factor between the module and the chamber. A correlation was determined using a parametric analysis by varying the surface emissivity and view factor until a good match was reached. This

  10. Mega-impacts and mantle-melting episodes: tests of possible correlations

    International Nuclear Information System (INIS)

    Glikson, A.Y.

    1996-01-01

    The criteria for recognising the effects of impacts by large-diameter extraterrestrial projectiles (D p >>10 km) on thin, geothermally active crust must vary fundamentally from those pertaining to impacts on thick, cooler continental crust. Although the bulk of the terrestrial cratering records has been destroyed by both erosion of elevated terrains and plate subduction, or obscured by burial, a search for Precambrian mega-impacts is facilitated by the preservation of their likely secondary effects: mega-earthquake-triggered faults; ensuing diamictites, and the deposits of turbidity currents; microtektites; spherulitic condensates of vaporised asteroid and target materials; and distal tectonic and igeneous effects. Clues to the origin of thermal events are provided by peaks on isotopic-age histograms of precise U-Pb, Ar-Ar, amd Sm-Nd mineral-whole-rock ages. These peaks, spatially corroborated by detailed mapping of Precambrian terrains, support an episodic nature of at least certain major Precambrian events and some correlations with impact events. Preliminary time-series analyses of Precambrian events yield values consistent with the Phanerozoic galactic rotation period (250 ± 50 Ma), and the solar system's cross-galactic-plane oscillation period (33 ± 3 Ma). It has been demonstrated that possible correlations between mega-impacts and tectonic/thermal events are capable of being tested through isotopic-age studies of diamictites and spherule units of impact origin and of rifting and mafic igneous events. 123 refs., 2 tabs., 7 figs

  11. Life satisfaction and its correlates among college students in China: a test of social reference theory.

    Science.gov (United States)

    Zhang, Jie; Zhao, Sibo; Lester, David; Zhou, Chengchao

    2014-08-01

    To study life satisfaction and to test the role of social reference in determining the degree of life satisfaction, we examined a large sample of undergraduate students in China for the correlates of campus life satisfaction. A questionnaire survey was administered at a university and the final sample consisted of 439 respondents aged between 17 and 24 years, from all over the country, and studying different subjects. It was found that freshman students tended to score higher on their life satisfaction than students in other grades and the college students' life satisfaction was positively related to female gender, self-esteem, social support, and the liberal attitudes on female gender roles, but negatively correlated with depression and suicidal ideation. Contrary to common beliefs, students from an urban area or from better-off families were not necessarily more satisfied with current life than those students coming from the countryside or low income families. The findings were accounted for by the social reference theory and in this case college students' campus life satisfaction is basically affected by their pre-college life quality as a reference. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Cognitive and neuropathologic correlates of Stroop Color-Word Test performance in Alzheimer's disease.

    Science.gov (United States)

    Bondi, Mark W; Serody, Adam B; Chan, Agnes S; Eberson-Shumate, Sonja C; Delis, Dean C; Hansen, Lawrence A; Salmon, David P

    2002-07-01

    The Stroop Color-Word Test (SCWT; C. Golden, 1978) was examined in 59 patients with probable Alzheimer's disease (AD) and in 51 demographically comparable normal control (NC) participants. AD patients produced significantly larger Stroop interference effects than NC participants, and level of dementia severity significantly influenced SCWT performance. Principal-components analyses demonstrated a dissociation in the factor structure of the Stroop trials between NC participants and AD patients, suggesting that disruption of semantic knowledge and speeded verbal processing in AD may be a major contributor to impairment on the incongruent trial. Results of clinicopathologic correlations in an autopsy-confirmed AD subgroup further suggest the invocation of a broad network of integrated cortical regions and executive and language processes underlying successful SCWT performance.

  13. The short half-life descendents from radon measured in Sao Jose dos Campos and Cachoeira Paulista, Brazil, and its correlation with meteorological data

    International Nuclear Information System (INIS)

    Andrade Marinho, E.V. de.

    1985-09-01

    The correlations between the activity of the short half-life radon decay products in the low atmosphere and the meterological parameters, measuring the atmospheric polonium 214 are studied. The aerosols were collected on membrane filters and analysed by alpha spectrometry. Measurements have been made in Sao Jose dos Campos and Cachoeira Paulista, in Brazil. At S. Jose dos Campos the influence of the pluviometry on the concentration of atmospheric Po 214 has been analysed, showing that high activity correspond to low pluviometry and inversely, low activities correspond to high pluviometry. At Cachoeira Paulista, the variation in the atmospheric Po 214 activity in corresation with the air stability, measured, showing the accumulation of radioactive aerosols during the greater stability in the the lower atmospheric layers, was studied. (author) [pt

  14. Mirroring the self: testing neurophysiological correlates of disturbed self-experience in schizophrenia spectrum.

    Science.gov (United States)

    Sestito, Mariateresa; Raballo, Andrea; Umiltà, Maria Alessandra; Leuci, Emanuela; Tonna, Matteo; Fortunati, Renata; De Paola, Giancarlo; Amore, Mario; Maggini, Carlo; Gallese, Vittorio

    2015-01-01

    Self-disorders (SDs) have been described as a core schizophrenia spectrum vulnerability phenotype, both in classic and contemporary psychopathological literature. However, such a core phenotype has not yet been investigated adopting a trans-domain approach that combines the phenomenological and the neurophysiological levels of analysis. The aim of this study is to investigate the relation between SDs and subtle, schizophrenia-specific impairments of emotional resonance that are supposed to reflect abnormalities in the mirror neurons mechanism. Specifically, we tested whether electromyographic response to emotional stimuli (i.e. a proxy for subtle changes in facial mimicry and related motor resonance mechanisms) would predict the occurrence of anomalous subjective experiences (i.e. SDs). Eighteen schizophrenia spectrum (SzSp) patients underwent a comprehensive psychopathological examination and were contextually tested with a multimodal paradigm, recording facial electromyographic activity of muscles in response to positive and negative emotional stimuli. Experiential anomalies were explored with the Bonn Scale for the Assessment of Basic Symptoms (BSABS) and then condensed into rational subscales mapping SzSp anomalous self-experiences. SzSp patients showed an imbalance in emotional motor resonance with a selective bias toward negative stimuli, as well as a multisensory integration impairment. Multiple regression analysis showed that electromyographic facial reactions in response to negative stimuli presented in auditory modality specifically and strongly correlated with SD subscore. The study confirms the potential of SDs as target phenotype for neurobiological research and encourages research into disturbed motor/emotional resonance as possible body-level correlate of disturbed subjective experiences in SzSp.

  15. Gastroesophageal reflux disease symptoms and dietary behaviors are significant correlates of short sleep duration in the general population: the Nagahama Study.

    Science.gov (United States)

    Murase, Kimihiko; Tabara, Yasuharu; Takahashi, Yoshimitsu; Muro, Shigeo; Yamada, Ryo; Setoh, Kazuya; Kawaguchi, Takahisa; Kadotani, Hiroshi; Kosugi, Shinji; Sekine, Akihiro; Nakayama, Takeo; Mishima, Michiaki; Chiba, Tsutomu; Chin, Kazuo; Matsuda, Fumihiko

    2014-11-01

    To examine relationships among gastroesophageal reflux disease (GERD) symptoms, dietary behaviors, and sleep duration in the general population. Cross-sectional. Community-based. There were 9,643 participants selected from the general population (54 ± 13 y). None. Sleep duration, sleep habits, and unfavorable dietary behaviors of each participant were assessed with a structured questionnaire. Participants were categorized into five groups according to their sleep duration: less than 5 h, 5 to less than 6 h, 6 to less than 7 h, 7 to less than 8 h, and 8 or more h per day. GERD was evaluated using the Frequency Scale for the Symptoms of GERD (FSSG) and participants having an FSSG score of 8 or more or those under treatment of GERD were defined as having GERD. Trend analysis showed that both the FSSG score and the number of unfavorable dietary habits increased with decreasing sleep duration. Further, multiple logistic regression analysis showed that both the presence of GERD (odds ratio = 1.19, 95% confidence interval (CI) = 1.07-1.32) and the number of unfavorable dietary behaviors (odds ratio = 1.19, 95% CI = 1.13-1.26) were independent and potent factors to identify participants with short sleep duration even after controlling for other confounding factors. The current study showed that both GERD symptoms and unfavorable dietary behaviors were significant correlates of short sleep duration independently of each other in a large sample from the general population.

  16. Correlation between Colon Transit Time Test Value and Initial Maintenance Dose of Laxative in Children with Chronic Functional Constipation

    Science.gov (United States)

    Kim, Mock Ryeon; Park, Hye Won; Son, Jae Sung; Lee, Ran

    2016-01-01

    Purpose To evaluate the correlation between colon transit time (CTT) test value and initial maintenance dose of polyethylene glycol (PEG) 4000 or lactulose. Methods Of 415 children with chronic functional constipation, 190 were enrolled based on exclusion criteria using the CTT test, defecation diary, and clinical chart. The CTT test was performed with prior disimpaction. The laxative dose for maintenance was determined on the basis of the defecation diary and clinical chart. The Shapiro-Wilk test and Pearson's and Spearman's correlations were used for statistical analysis. Results The overall group median value and interquartile range of the CTT test was 43.8 (31.8) hours. The average PEG 4000 dose for maintenance in the overall group was 0.68±0.18 g/kg/d; according to age, the dose was 0.73±0.16 g/kg/d (encopresis, abnormal CTT test subtype) for either laxative. Even in the largest group (overall, n=109, younger than 8 years and on PEG 4000), the correlation was weak (Pearson's correlation coefficient [R]=0.268, p=0.005). Within the abnormal transit group, subgroup (n=73, younger than 8 years and on PEG 4000) correlation was weak (R=0.267, p=0.022). Conclusion CTT test value cannot predict the initial maintenance dose of PEG 4000 or lactulose with linear correlation. PMID:27738600

  17. Test of Lorentz and CPT violation with short baseline neutrino oscillation excesses

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar-Arevalo, A.A. [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, D.F. 04510 (Mexico); Anderson, C.E. [Yale University, New Haven, CT 06520 (United States); Bazarko, A.O. [Princeton University, Princeton, NJ 08544 (United States); Brice, S.J.; Brown, B.C. [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Bugel, L. [Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Cao, J. [University of Michigan, Ann Arbor, MI 48109 (United States); Coney, L. [Columbia University, New York, NY 10027 (United States); Conrad, J.M. [Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Cox, D.C. [Indiana University, Bloomington, IN 47405 (United States); Curioni, A. [Yale University, New Haven, CT 06520 (United States); Dharmapalan, R. [University of Alabama, Tuscaloosa, AL 35487 (United States); Djurcic, Z. [Argonne National Laboratory, Argonne, IL 60439 (United States); Finley, D.A. [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Fleming, B.T. [Yale University, New Haven, CT 06520 (United States); Ford, R.; Garcia, F.G. [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Garvey, G.T. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Grange, J. [University of Florida, Gainesville, FL 32611 (United States); Green, C. [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); and others

    2013-01-29

    The sidereal time dependence of MiniBooNE {nu}{sub e} and {nu}{sup Macron }{sub e} appearance data is analyzed to search for evidence of Lorentz and CPT violation. An unbinned Kolmogorov-Smirnov (K-S) test shows both the {nu}{sub e} and {nu}{sup Macron }{sub e} appearance data are compatible with the null sidereal variation hypothesis to more than 5%. Using an unbinned likelihood fit with a Lorentz-violating oscillation model derived from the Standard Model Extension (SME) to describe any excess events over background, we find that the {nu}{sub e} appearance data prefer a sidereal time-independent solution, and the {nu}{sup Macron }{sub e} appearance data slightly prefer a sidereal time-dependent solution. Limits of order 10{sup -20} GeV are placed on combinations of SME coefficients. These limits give the best limits on certain SME coefficients for {nu}{sub {mu}}{yields}{nu}{sub e} and {nu}{sup Macron }{sub {mu}}{yields}{nu}{sup Macron }{sub e} oscillations. The fit values and limits of combinations of SME coefficients are provided.

  18. Short-term forecasting of non-OPEC supply: a test of seasonality and seasonal decomposition

    International Nuclear Information System (INIS)

    Jazayeri, S.M.R.T.; Yahyai, A.

    2002-01-01

    The purpose of this study is, first to find out, based on historical data, whether quarterly averages of non-OPEC supply follow a seasonal pattern. If that is mathematically established, then, secondly, it is attempted to estimate the best seasonal factors to decompose the estimated yearly average into seasonal averages. This study applies the Fourier analysis to quarterly supply series to test for seasonality, and provides estimates of seasonal factors for the year 2001 by applying the so-called X-11 decomposition method to the annual estimate. A set of historical data, consisting of quarterly supply averages of individual countries, regional subtotals and aggregate non-OPEC for the period 1971-2000, forms the basis of the analysis. Through the application of the Fourier analysis and X-11 decomposition method, it is demonstrated that quarterly non-OPEC supply, be it by an individual major producer or regional sub-totals, clearly follows a seasonal pattern. This is a very useful conclusion for the market analyst involved with forecasting the quarterly supply. (author)

  19. Short-term effect of dark chocolate consumption on routine haemostasis testing.

    Science.gov (United States)

    Montagnana, Martina; Danese, Elisa; Salvagno, Gian Luca; Lippi, Giuseppe

    2017-08-01

    This experimental study was designed to investigate the sort-term impact of dark chocolate ingestion on routine haemostasis tests in healthy volunteers. The study population consisted in 15 healthy male volunteers who ingested 50 g of 90% cocoa chocolate within 3-5 min. Blood was drawn early in the morning, immediately before chocolate ingestion and 4 h afterwards, for assessment of activated partial thromboplastin time (APTT), prothrombin time (PT) and fibrinogen. A significant increase of triglycerides (1.4 ± 0.6 versus 1.0 ± 0.5 mmol/L; p < .001), APTT (32.1 ± 2.2 versus 31.1 ± 2.0 s; p < .001) and PT (9.8 ± 0.5 versus 9.7 ± 0.4 s; p = .008) was observed 4 h after ingestion of dark chocolate, whereas fibrinogen values remained unchanged (2.6 ± 0.5 versus 2.5 ± 0.5 g/L; p = .063). Overall, we observed a mean percentage increase of 3.1% for APTT and 1.2% for PT. These results suggest that dark chocolate intake may have an impact on secondary haemostasis.

  20. Test of Lorentz and CPT violation with short baseline neutrino oscillation excesses

    International Nuclear Information System (INIS)

    Aguilar-Arevalo, A.A.; Anderson, C.E.; Bazarko, A.O.; Brice, S.J.; Brown, B.C.; Bugel, L.; Cao, J.; Coney, L.; Conrad, J.M.; Cox, D.C.; Curioni, A.; Dharmapalan, R.; Djurcic, Z.; Finley, D.A.; Fleming, B.T.; Ford, R.; Garcia, F.G.; Garvey, G.T.; Grange, J.; Green, C.

    2013-01-01

    The sidereal time dependence of MiniBooNE ν e and ν ¯ e appearance data is analyzed to search for evidence of Lorentz and CPT violation. An unbinned Kolmogorov–Smirnov (K–S) test shows both the ν e and ν ¯ e appearance data are compatible with the null sidereal variation hypothesis to more than 5%. Using an unbinned likelihood fit with a Lorentz-violating oscillation model derived from the Standard Model Extension (SME) to describe any excess events over background, we find that the ν e appearance data prefer a sidereal time-independent solution, and the ν ¯ e appearance data slightly prefer a sidereal time-dependent solution. Limits of order 10 −20 GeV are placed on combinations of SME coefficients. These limits give the best limits on certain SME coefficients for ν μ →ν e and ν ¯ μ →ν ¯ e oscillations. The fit values and limits of combinations of SME coefficients are provided.

  1. 40 CFR 86.163-00 - Spot check correlation procedures for vehicles tested using a simulation of the environmental...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Spot check correlation procedures for... Complete Heavy-Duty Vehicles; Test Procedures § 86.163-00 Spot check correlation procedures for vehicles... running change approval, each model year for any manufacturer undergoing the spot checking procedures of...

  2. Investigating the Correlation Between Pharmacy Student Performance on the Health Science Reasoning Test and a Critical Thinking Assignment

    OpenAIRE

    Nornoo, Adwoa O.; Jackson, Jonathan; Axtell, Samantha

    2017-01-01

    Objective. To determine whether there is a correlation between pharmacy students? scores on the Health Science Reasoning Test (HSRT) and their grade on a package insert assignment designed to assess critical thinking.

  3. The Category Cued Recall test in very mild Alzheimer's disease: discriminative validity and correlation with semantic memory functions.

    Science.gov (United States)

    Vogel, A; Mortensen, E L; Gade, A; Waldemar, G

    2007-01-01

    Episodic memory tests that measure cued recall may be particularly effective in the diagnosis of early Alzheimer's disease (AD) because they examine both episodic and semantic memory functions. The Category Cued Recall (CCR) test provides superordinate semantic cues at encoding and retrieval, and high discriminative validity has been claimed for this test. The aim of this study was to investigate the discriminative validity for this test when compared with the 10-word memory list from Alzheimer's Disease Assessment Scale (ADAS-cog) that measures free recall. The clinical diagnosis of AD was taken as the standard. It was also investigated whether the two episodic memory tests correlated with measures of semantic memory. The tests were administered to 35 patients with very mild AD (Mini Mental State Examination score >22) and 28 control subjects. Both tests had high sensitivity (>88%) with high specificity (>89%). One out of the five semantic memory tests was significantly correlated to performances on CCR, whereas delayed recall on the ADAS-cog memory test was significantly correlated to two semantic tests. In conclusion, the discriminative validity of the CCR test and the ADAS-cog memory test was equivalent in very mild AD. This may be because CCR did not tap more semantic processes, which are impaired in the earliest phases of AD, than a test of free recall.

  4. The short-circuit test results of 6.9 kV/2.3 kV 400 kVA-class YBCO model transformer

    International Nuclear Information System (INIS)

    Tomioka, A.; Otonari, T.; Ogata, T.; Iwakuma, M.; Okamoto, H.; Hayashi, H.; Iijima, Y.; Saito, T.; Gosho, Y.; Tanabe, K.; Izumi, T.; Shiohara, Y.

    2011-01-01

    The 6.9 kV/2.3 kV 400 kVA-class single-phase YBCO model transformer with the YBCO tape with copper tape was manufactured for short-circuit current test. Short-circuit test was performed and the short-circuit current of primary winding was 346 A which was about six times larger than the rated current. The I-V characteristics of the winding did not change before and after the test. The transformer withstood short-circuit current. We are planning to turn the result into a consideration of a 66 kV/6.9 kV-20 MVA-class three-phase superconducting transformer. We are developing an elemental technology for 66 kV/6.9 kV 20 MVA-class power transformer with YBCO conductors. The protection of short-circuit technology is one of the elemental technologies for HTS transformer. Since short-circuit current is much higher than critical current of YBCO tape, there is a possibility that superconducting characteristics may be damaged during short-circuit period. We made a conductor to compose the YBCO tape with copper tape. We manufactured 6.9 kV/2.3 kV 400 kVA-class YBCO model transformer using this conductor and performed short-circuit current test. The short-circuit current of primary winding was 346 A which was about six times larger than the rated current. The I-V characteristics of the winding did not change before and after the test. We may consider this conductor withstands short-circuit current.

  5. Tissue identity testing of cancer by short tandem repeat polymorphism: pitfalls of interpretation in the presence of microsatellite instability.

    Science.gov (United States)

    Much, Melissa; Buza, Natalia; Hui, Pei

    2014-03-01

    Tissue identity testing by short tandem repeat (STR) polymorphism offers discriminating power in resolving tissue mix-up or contamination. However, one caveat is the presence of microsatellite unstable tumors, in which genetic alterations may drastically change the STR wild-type polymorphism leading to unexpected allelic discordance. We examined how tissue identity testing results can be altered by the presence of microsatellite instability (MSI). Eleven cases of MSI-unstable (9 intestinal and 2 endometrial adenocarcinomas) and 10 cases of MSI-stable tumors (all colorectal adenocarcinomas) were included. All had been previously tested by polymerase chain reaction testing at 5 National Cancer Institute (NCI) recommended MSI loci and/or immunohistochemistry for DNA mismatch repair proteins (MLH1, MSH2, MSH6, and PMS2). Tissue identity testing targeting 15 STR loci was performed using AmpF/STR Identifiler Amplification. Ten of 11 MSI-unstable tumors demonstrated novel alleles at 5 to 12 STR loci per case and frequently with 3 or more allelic peaks. However, all affected loci showed identifiable germline allele(s) in MSI-high tumors. A wild-type allelic profile was seen in 7 of 10 MSI-stable tumors. In the remaining 3 cases, isolated novel alleles were present at a unique single locus in addition to germline alleles. Loss of heterozygosity was observed frequently in both MSI-stable (6/11 cases) and MSI-unstable tumors (8/10 cases). In conclusion, MSI may significantly alter the wild-type allelic polymorphism, leading to potential interpretation errors of STR genotyping. Careful examination of the STR allelic pattern, high index of suspicion, and follow-up MSI testing are crucial to avoid erroneous conclusions and subsequent clinical and legal consequences. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Kinematic Orbit Determination Method Optimization and Test Analysis for BDS Satellites with Short-arc Tracking Data

    Directory of Open Access Journals (Sweden)

    GUO Rui

    2017-04-01

    Full Text Available Rapid orbit recovery is a puzzle for the BDS satellites after orbit maneuvers. Two kinematic orbit determination methods are studied, with two orbit determination models being established. The receiver system error and serious multipath error exist in the BDS system. The co-location method is proposed to estimate and calibrate the receiver system errors. A CNMC (code noise and multipath correction method is introduced to weaken the multipath error. Therefore the data quality is controlled efficiently for the receivers in the short tracking arc. The GEO/IGSO/MEO real data is emploied to carry out tests and validation. Using 10 min short tracking arc, the kinematic precise orbit determination accuracy is about 3.27 m for the GEOs, and 8.19 m for the IGSOs, and 5.9 m for the MEOs. Rapid orbit determination is achieved, which satisfying the orbit requirements from the BDS RDSS services. The kinematic precise orbit determination method also supports the RDSS service walking up to the global world.

  7. Assembly Tests of the First Nb$_{3}$Sn Low-Beta Quadrupole Short Model for the Hi-Lumi LHC

    CERN Document Server

    Pan, H; Cheng, D W; Anderssen, E; Ambrosio, G; Perez, J C; Juchno, M; Ferracin, P; Prestemon, S O

    2016-01-01

    In preparation for the high-luminosity upgrade of the Large Hadron Collider (LHC), the LHC Accelerator Research Program (LARP) in collaboration with CERN is pursuing the development of MQXF: a 150-mm-aperture high-field Nb$_{3}$Sn quadrupole magnet. The development phase starts with the fabrication and test of several short models (1.2-m magnetic length) and will continue with the development of several long prototypes. All of them are mechanically supported using a shell-based support structure, which has been extensively demonstrated on several R&D; models within LARP. The first short model MQXFS-AT has been assembled at LBNL with coils fabricated by LARP and CERN. In this paper, we summarize the assembly process and show how it relies strongly on experience acquired during the LARP 120-mm-aperture HQ magnet series. We present comparison between strain gauges data and finite-element model analysis. Finally, we present the implication of the MQXFS-AT experience on the design of the long prototype support...

  8. Structural neurobiological correlates of Mayer-Salovery-Caruso Emotional Intelligence Test performance in early course schizophrenia.

    Science.gov (United States)

    Wojtalik, Jessica A; Eack, Shaun M; Keshavan, Matcheri S

    2013-01-10

    The Mayer-Salovey-Caruso Emotional Intelligence Test (MSCEIT) is a key measure of social cognition in schizophrenia that has good psychometric properties and is recommended by the MATRICS committee. As a way to further investigate the validity of the MSCEIT, this study sought to examine the neurobiological correlates of MSCEIT performance in patients with early course schizophrenia. A total of 51 patients diagnosed with early course, stabilized schizophrenia or schizoaffective disorder completed structural magnetic resonance imaging (MRI) scans and the MSCEIT. Investigation of the associations between MSCEIT performance and gray matter morphology was examined by conducting voxel-based morphometry (VBM) analyses across hypothesized social-cognitive regions of interest using automated anatomical labeling in Statistical Parametric Mapping Software, version 5 (SPM5). All VBM analyses utilized general linear models examining gray matter density partitioned images, adjusting for demographic and illness-related confounds. VBM results were then followed up with confirmatory volumetric analyses. Patients with poorer overall and Facilitating, Understanding, and Managing Emotions subscale performances on the MSCEIT showed significantly reduced gray matter density in the left parahippocampal gyrus. Additionally, attenuated performance on the Facilitating and Managing Emotions subscales was significantly associated with reduced right posterior cingulate gray matter density. All associations observed between MSCEIT performance and gray matter density were supported with confirmatory gray matter volumetric analyses, with the exception of the association between the right posterior cingulate and the facilitation of emotions. These findings provide additional evidence for the MSCEIT as a valid social-cognitive measure by elucidating its correlates with neurobiological structures commonly implicated in emotion processing. These findings provide additional biological evidence

  9. Short-term delayed recall of auditory verbal learning test is equivalent to long-term delayed recall for identifying amnestic mild cognitive impairment.

    Directory of Open Access Journals (Sweden)

    Qianhua Zhao

    Full Text Available Delayed recall of words in a verbal learning test is a sensitive measure for the diagnosis of amnestic mild cognitive impairment (aMCI and early Alzheimer's disease (AD. The relative validity of different retention intervals of delayed recall has not been well characterized. Using the Auditory Verbal Learning Test-Huashan version, we compared the differentiating value of short-term delayed recall (AVL-SR, that is, a 3- to 5-minute delay time and long-term delayed recall (AVL-LR, that is, a 20-minute delay time in distinguishing patients with aMCI (n = 897 and mild AD (n = 530 from the healthy elderly (n = 1215. In patients with aMCI, the correlation between AVL-SR and AVL-LR was very high (r = 0.94, and the difference between the two indicators was less than 0.5 points. There was no difference between AVL-SR and AVL-LR in the frequency of zero scores. In the receiver operating characteristic curves analysis, although the area under the curve (AUC of AVL-SR and AVL-LR for diagnosing aMCI was significantly different, the cut-off scores of the two indicators were identical. In the subgroup of ages 80 to 89, the AUC of the two indicators showed no significant difference. Therefore, we concluded that AVL-SR could substitute for AVL-LR in identifying aMCI, especially for the oldest patients.

  10. The University of Minnesota aquifer thermal energy storage (ATES) field test facility -- system description, aquifer characterization, and results of short-term test cycles

    Energy Technology Data Exchange (ETDEWEB)

    Walton, M.; Hoyer, M.C.; Eisenreich, S.J.; Holm, N.L.; Holm, T.R.; Kanivetsky, R.; Jirsa, M.A.; Lee, H.C.; Lauer, J.L.; Miller, R.T.; Norton, J.L.; Runke, H. (Minnesota Geological Survey, St. Paul, MN (United States))

    1991-06-01

    Phase 1 of the Aquifer Thermal Energy Storage (ATES) Project at the University of Minnesota was to test the feasibility, and model, the ATES concept at temperatures above 100{degrees}C using a confined aquifer for the storage and recovery of hot water. Phase 1 included design, construction, and operation of a 5-MW thermal input/output field test facility (FTF) for four short-term ATES cycles (8 days each of heat injection, storage, and heat recover). Phase 1 was conducted from May 1980 to December 1983. This report describes the FTF, the Franconia-Ironton-Galesville (FIG) aquifer used for the test, and the four short-term ATES cycles. Heat recovery; operational experience; and thermal, chemical, hydrologic, and geologic effects are all included. The FTF consists of monitoring wells and the source and storage well doublet completed in the FIG aquifer with heat exchangers and a fixed-bed precipitator between the wells of the doublet. The FIG aquifer is highly layered and a really anisotropic. The upper Franconia and Ironton-Galesville parts of the aquifer, those parts screened, have hydraulic conductivities of {approximately}0.6 and {approximately}1.0 m/d, respectively. Primary ions in the ambient ground water are calcium and magnesium bicarbonate. Ambient temperature FIG ground water is saturated with respect to calcium/magnesium bicarbonate. Heating the ground water caused most of the dissolved calcium to precipitate out as calcium carbonate in the heat exchanger and precipitator. Silica, calcium, and magnesium were significantly higher in recovered water than in injected water, suggesting dissolution of some constituents of the aquifer during the cycles. Further work on the ground water chemistry is required to understand water-rock interactions.

  11. Analysis of the existing correlations of effective friction angle for eastern piedmont soils of Bogota from in situ tests

    Directory of Open Access Journals (Sweden)

    July E. Carmona-Álvarez

    2015-07-01

    Full Text Available To estimate the effective friction angle of soil from in situ test is a complicated job, due to high rates of strain existing in this kind of tests, which tend to be too invasive and disturb the vicinities of test depth, even the sample that eventually is taken at the site. Likewise, the most of the correlations found in the current bibliography to obtain the effective friction angle using field tests, have been developed for soils from different regions. For that reason when are implemented on tropical soils present high scatter, to compare the field parameter values with real results obtained at the lab. This research aims to use in situ tests define through of analysis of different correlations, which fits adequately to the specific conditions of the piedmont soils of Bogota. For the present study will be utilized data from SPT (widely used in Colombia and SPT-T (never before conducted in the country, carried out considering the appropriated norms to each test, taking in account to SPT-T, doesn’t exist local standard governing such tests. The correlations for field procedures of the tests implemented were for effective confining and energy transference of the SPT hammer, since the state-of-the-art mentions it as the most affect the reliability of the final results. The final results show the tendency of the methodologies used to obtain the correlation, in relation with the real value of effective friction angle from of lab tests.

  12. The Applicability of a Short-term Test for Detection of Modifying Effects of Dietary Factors in Rodent Colon Carcinogenesis

    DEFF Research Database (Denmark)

    Kristiansen, Eva

    The present studies were initiated to develop a short-term rodent model to assess the influence of different dietary components on the development of colon cancer. Diets with different dietary components, i.e. dietary fibre, fat, sucrose, and starches were tested in male rats initiated with DMH-2......HCl or AOM for their modulating effect on the development of aberrant crypt foci (ACF). Furthermore the heterocyclic amines IQ and PhIP were introduced in the assay as inducers of ACF in mice and rats and their role in colon carcinogenesis in mice was investigated. ACF were found to be induced...... in rodent colon by the colon carcinogens DMH-2HC1, AOM, IQ, and PhIP and it was shown that the incidence of the induced ACF could be modulated by dietary components such as sucrose, dietary fibre, and starch....

  13. Test anxiety in medical school is unrelated to academic performance but correlates with an effort/reward imbalance.

    Science.gov (United States)

    Hahn, Henry; Kropp, Peter; Kirschstein, Timo; Rücker, Gernot; Müller-Hilke, Brigitte

    2017-01-01

    During their early years at medical school, students repeatedly criticize their workload, time constraints and test associated stress. At the same time, depressiveness and anxiety among first and second year medical students are on the rise. We therefore hypothesized that test anxiety may be related to depressiveness and considered cognitive and academic performances as confounders for the former and psychosocial distress for the latter. A whole class of 200 second year students was invited to participate in the study. Anxiety as a trait, depressiveness, crystallized intelligence, verbal fluency and psychosocial distress were assessed using validated tests and questionnaires. Acute state anxiety and sympathetic stress parameters were measured in real life situations immediately before an oral and a written exam and paired tests were used to compare the individual anxieties at the various time points. Previous academic performances were self-reported, the results of the impending exams were monitored. Finally, correlations were performed to test for interrelatedness between academic performances and the various personal, cognitive and psychosocial factors. Acute test anxiety did not correlate with depressiveness nor did it correlate with previous nor impending academic performances nor any of the expected confounders on academic performance. However both, depressiveness and test anxiety strongly correlated with the perceived imbalance between efforts spent and rewards received. Moreover, anxiety as a trait not only correlated with acute state anxiety before an exam but was also significantly correlated to the feeling of over-commitment. Depressiveness during the early years of medical school seems unrelated to test anxiety and academic performance. Instead, it strongly correlated with the psychosocial distress emanating from attending medical school and points at a perceived imbalance between efforts spent and rewards received.

  14. Quick screening of cognitive function in Indian multiple sclerosis patients using Montreal cognitive assessment test-short version

    Directory of Open Access Journals (Sweden)

    Darshpreet Kaur

    2013-01-01

    Full Text Available Background: Cognitive impairments in multiple sclerosis (MS are now well recognized worldwide, but unfortunately this domain has been less explored in India due to many undermining factors. The aim of this study was to evaluate cognitive impairments in Indian MS patients with visual or upper limb motor problems with the help of short version of Montreal cognitive assessment test (MoCA. Subjects and Methods: Thirty MS patients and 50 matched controls were recruited for the 12 points MoCA task. Receiver operating characteristic curve (ROC analysis was performed to determine optimal sensitivity and specificity of the 12 points MoCA in differentiating cognitively impaired patients and controls. Results: The mean 12 points MoCA scores of the controls and MS patients were 11.56 ± 0.67 and 8.06 ± 1.99, respectively. In our study, the optimal cut-off value for 12 points MoCA to be able to differentiate patients with cognitive impairments from controls is 10/12. Accordingly, 73.3% patients fell below the cut off value. Both the groups did not have significant statistical differences with regard to age and educational years. Conclusion: The 12 points, short version of MoCA, is a useful brief screening tool for quick and early detection of mild cognitive impairments in subjects with MS. It can be administered to patients having visual and motor problems. It is of potential use by primary care physicians, nurses, and other allied health professionals who need a quick screening test. No formal training for administration is required. Financial and time constraints should not limit the use of the proposed instrument.

  15. Potential Functional Embedding Theory at the Correlated Wave Function Level. 2. Error Sources and Performance Tests.

    Science.gov (United States)

    Cheng, Jin; Yu, Kuang; Libisch, Florian; Dieterich, Johannes M; Carter, Emily A

    2017-03-14

    Quantum mechanical embedding theories partition a complex system into multiple spatial regions that can use different electronic structure methods within each, to optimize trade-offs between accuracy and cost. The present work incorporates accurate but expensive correlated wave function (CW) methods for a subsystem containing the phenomenon or feature of greatest interest, while self-consistently capturing quantum effects of the surroundings using fast but less accurate density functional theory (DFT) approximations. We recently proposed two embedding methods [for a review, see: Acc. Chem. Res. 2014 , 47 , 2768 ]: density functional embedding theory (DFET) and potential functional embedding theory (PFET). DFET provides a fast but non-self-consistent density-based embedding scheme, whereas PFET offers a more rigorous theoretical framework to perform fully self-consistent, variational CW/DFT calculations [as defined in part 1, CW/DFT means subsystem 1(2) is treated with CW(DFT) methods]. When originally presented, PFET was only tested at the DFT/DFT level of theory as a proof of principle within a planewave (PW) basis. Part 1 of this two-part series demonstrated that PFET can be made to work well with mixed Gaussian type orbital (GTO)/PW bases, as long as optimized GTO bases and consistent electron-ion potentials are employed throughout. Here in part 2 we conduct the first PFET calculations at the CW/DFT level and compare them to DFET and full CW benchmarks. We test the performance of PFET at the CW/DFT level for a variety of types of interactions (hydrogen bonding, metallic, and ionic). By introducing an intermediate CW/DFT embedding scheme denoted DFET/PFET, we show how PFET remedies different types of errors in DFET, serving as a more robust type of embedding theory.

  16. Risk of false decision on conformity of a multicomponent material when test results of the components' content are correlated.

    Science.gov (United States)

    Kuselman, Ilya; Pennecchi, Francesca R; da Silva, Ricardo J N B; Hibbert, D Brynn

    2017-11-01

    The probability of a false decision on conformity of a multicomponent material due to measurement uncertainty is discussed when test results are correlated. Specification limits of the components' content of such a material generate a multivariate specification interval/domain. When true values of components' content and corresponding test results are modelled by multivariate distributions (e.g. by multivariate normal distributions), a total global risk of a false decision on the material conformity can be evaluated based on calculation of integrals of their joint probability density function. No transformation of the raw data is required for that. A total specific risk can be evaluated as the joint posterior cumulative function of true values of a specific batch or lot lying outside the multivariate specification domain, when the vector of test results, obtained for the lot, is inside this domain. It was shown, using a case study of four components under control in a drug, that the correlation influence on the risk value is not easily predictable. To assess this influence, the evaluated total risk values were compared with those calculated for independent test results and also with those assuming much stronger correlation than that observed. While the observed statistically significant correlation did not lead to a visible difference in the total risk values in comparison to the independent test results, the stronger correlation among the variables caused either the total risk decreasing or its increasing, depending on the actual values of the test results. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Pull test performance and correlation with falls risk in Parkinson?s disease

    Directory of Open Access Journals (Sweden)

    Renato P. Munhoz

    2014-08-01

    Full Text Available Postural instability (PI and falls are major sources of disability in Parkinson’s disease (PD. Our objectives were to evaluate the correlation between the pull-test (PT scores and falls. Patients underwent a standardized data collection including demographic, clinical data, and the UPDRS scores for falls and the PT. Cases with scores >1 for falls were considered frequent fallers. 264 patients were included with mean age 67.6±10 years, mean age of onset 59.1±10.7 years. Comparison between PT scores versus the proportion of frequent fallers and the mean score of the UPDRS for falls showed that for each increase in the PT score, both parameters were significantly worse, with positive linear relationship. For any abnormal PT score, sensibility and negative predictive value were excellent; specificity and positive predictive value improved with worse PT scores. In conclusion, the PT provides important and reliable information regarding PI and the risk of falls in PD.

  18. Tityus serrulatus Scorpion Venom: In Vitro Tests and Their Correlation with In Vivo Lethal Dose Assay

    Directory of Open Access Journals (Sweden)

    Daniela Cajado-Carvalho

    2017-11-01

    Full Text Available Scorpion stings are the main cause of human envenomation in Brazil and, for the treatment of victims, the World Health Organization (WHO recommends the use of antivenoms. The first step to achieve effective antivenom is to use a good quality venom pool and to evaluate it, with LD50 determination as the most accepted procedure. It is, however, time-consuming and requires advanced technical training. Further, there are significant ethical concerns regarding the number of animals required for testing. Hence, we investigated the correspondence between LD50 results, in vitro assays, and a strong correlation with proteolytic activity levels was observed, showing, remarkably, that proteases are potential toxicity markers for Tityus serrulatus venom. The comparison of reversed-phase chromatographic profiles also has a potential application in venoms’ quality control, as there were fewer neurotoxins detected in the venom with high LD50 value. These results were confirmed by mass spectrometry analysis. Therefore, these methods could precede the LD50 assay to evaluate the venom excellence by discriminating—and discarding—poor-quality batches, and, consequently, with a positive impact on the number of animals used. Notably, proposed assays are fast and inexpensive, being technically and economically feasible in Tityus serrulatus venom quality control to produce effective antivenoms.

  19. Implementation and Initial Testing of Advanced Processing and Analysis Algorithms for Correlated Neutron Counting

    Energy Technology Data Exchange (ETDEWEB)

    Santi, Peter Angelo [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Cutler, Theresa Elizabeth [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Favalli, Andrea [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Koehler, Katrina Elizabeth [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Henzl, Vladimir [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Henzlova, Daniela [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Parker, Robert Francis [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Croft, Stephen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-12-01

    In order to improve the accuracy and capabilities of neutron multiplicity counting, additional quantifiable information is needed in order to address the assumptions that are present in the point model. Extracting and utilizing higher order moments (Quads and Pents) from the neutron pulse train represents the most direct way of extracting additional information from the measurement data to allow for an improved determination of the physical properties of the item of interest. The extraction of higher order moments from a neutron pulse train required the development of advanced dead time correction algorithms which could correct for dead time effects in all of the measurement moments in a self-consistent manner. In addition, advanced analysis algorithms have been developed to address specific assumptions that are made within the current analysis model, namely that all neutrons are created at a single point within the item of interest, and that all neutrons that are produced within an item are created with the same energy distribution. This report will discuss the current status of implementation and initial testing of the advanced dead time correction and analysis algorithms that have been developed in an attempt to utilize higher order moments to improve the capabilities of correlated neutron measurement techniques.

  20. Correlation of levels of obstruction in COPD with lactate and six-minute walk test

    Directory of Open Access Journals (Sweden)

    Dante Brasil Santos

    2009-01-01

    Full Text Available Chronic obstructive pulmonary disease (COPD is a leading cause of morbid-mortality world wide, leading not only to pulmonary damage but also to multisystemic impairment, with repercussions on skeletal muscles and the ability to undertake effort, as measured in the six-minute walk test (6-MWT. Aims: To correlate the level of obstruction in COPD with lactate concentration and heart rate (HR at rest, and distance walked. To correlate distance walked with blood gas analysis and correlate desaturation in 6-MWT with post 6-MWT lactate concentration and heart rate. Methods: COPD patients underwent spirometry, blood gas analysis and 6-MWT to evaluate distance walked, heart rate, capillary lactate (CL concentration pre– and post 6MWT, and desaturation with 6-MWT. Results: 91 patients with all levels of obstruction were evaluated. HR and CL increased significantly post 6-MWT. The decrease in peripheral saturation of haemoglobin to oxygen observed with 6-MWT was also significant. The distance walked was shorter the greater the obstruction. The correlation analysis was significantly positive between FEV1 and distance walked, negative between FEV1 and HR at rest and negative between distance walked and PaCO2, and not significant for the other variables. Conclusions: Increased obstruction in COPD and higher PaCO2 values contribute to a reduction in distance walked in 6-MWT. The level of obstruction in COPD leads to a haemodynamic impairment with increased HR at rest of these patients. Resumo: Contextualização: A doença pulmonar obstrutiva crónica (DPOC, importante causa de morbimortalidade em todo mundo, leva não só ao comprometimento pulmonar, mas também a alterações sistémicas, com repercussões sobre músculos esqueléticos e a capacidade de realizar esforços, mensurável pelo teste de caminhada de seis minutos (TC6’. Objectivos: correlacionar obstrução da DPOC com lactato de repouso, frequ

  1. Preliminary Correlation Map of Geomorphic Surfaces in North-Central Frenchman Flat, Nevada Test Site

    International Nuclear Information System (INIS)

    Bechtel Nevada

    2005-01-01

    This correlation map (scale = 1:12,000) presents the results of a mapping initiative that was part of the comprehensive site characterization required to operate the Area 5 Radioactive Waste Management Site, a low-level radioactive waste disposal facility located in northern Frenchman Flat at the Nevada Test Site. Eight primary map units are recognized for Quaternary surfaces: remnants of six alluvial fan or terrace surfaces, one unit that includes colluvial aprons associated with hill slopes, and one unit for anthropogenically disturbed surfaces. This surficial geology map provides fundamental data on natural processes for reconstruction of the Quaternary history of northern Frenchman Flat, which in turn will aid in the understanding of the natural processes that act to develop the landscape, and the time-frames involved in landscape development. The mapping was conducted using color and color-infrared aerial photographs and field verification of map unit composition and boundaries. Criteria for defining the map unit composition of geomorphic surface units are based on relative geomorphic position, landform morphology, and degree of preservation of surface morphology. The bedrock units identified on this map were derived from previous published mapping efforts and are included for completeness

  2. Three experimental tests of Bell's inequalities by measurement of polarization correlation of photons

    International Nuclear Information System (INIS)

    Aspect, A.

    1983-02-01

    We have performed three experimental tests of Bell's inequalities by measuring the linear-polarization correlation of photons emitted by pairs in the 4p 2 1 S 0 → 4s4p 1 P 1 → 4s 2 1 S 0 radiative cascade of calcium. The first part of this dissertation reminds the theoretical background (Bell's theorem), and the experimental situation (previous experiments). We then describe our apparatus: the source (calcium atomic beam selectively excited by two-photon absorption), the optics, the photon coincidence-counting system. Our first experiment, analogous to previous ones (but more precise) involves one-channel polarizers. Our second experiment, based on a conceptually simpler scheme, uses two-channel polarizers. The third experiment involves acousto-optical switches followed by two linear polarizers: these devices act as time-varying polarizers, the orientation of which is changed during the time of flight of photons. In the three experiments, the results are in good agreement with the Quantum mechanical predictions, and they distinctly violate the relevant Bell's inequalities [fr

  3. Detecting dementia in patients with normal neuropsychological screening by Short Smell Test and Palmo-Mental Reflex Test: an observational study.

    Science.gov (United States)

    Streit, Sven; Limacher, Andreas; Zeller, Andreas; Bürge, Markus

    2015-07-25

    General practitioners (GPs) are in best position to suspect dementia. Mini-Mental State Examination (MMSE) and Clock Drawing Test (CDT) are widely used. Additional neurological tests may increase the accuracy of diagnosis. We aimed to evaluate diagnostic ability to detect dementia with a Short Smell Test (SST) and Palmo-Mental Reflex (PMR) in patients whose MMSE and CDT are normal, but who show signs of cognitive dysfunction. This was a 3.5-year cross-sectional observational study in the Memory Clinic of the University Department of Geriatrics in Bern, Switzerland. Participating patients with normal MMSE (>26 points) and CDT (>5 points) were referred by GPs because they suspected dementia. All were examined according to a standardized protocol. Diagnosis of dementia was based on DSM-IV TR criteria. We used SST and PMR to determine if they accurately detected dementia. In our cohort, 154 patients suspected of dementia had normal MMSE and CDT test results. Of these, 17 (11%) were demented. If SST or PMR were abnormal, sensitivity was 71% (95% CI 44-90%), and specificity 64% (95% CI 55-72%) for detecting dementia. If both tests were abnormal, sensitivity was 24% (95% CI 7-50%), but specificity increased to 93% (95% CI 88-97%). Patients suspected of dementia, but with normal MMSE and CDT results, may benefit if SST and PMR are added as diagnostic tools. If both SST and PMR are abnormal, this is a red flag to investigate these patients further, even though their negative neuropsychological screening results.

  4. Behavioral and Psychosocial Correlates of HIV Testing Among Male Clients of Female Sex Workers in Tijuana, Mexico.

    Science.gov (United States)

    Fleming, Paul J; Patterson, Thomas L; Chavarin, Claudia V; Semple, Shirley J; Magis-Rodriguez, Carlos; Pitpitan, Eileen V

    2017-08-01

    We use data collected from a sample of 400 male clients of female sex workers (FSW) to examine their HIV testing behavior. We present frequencies of HIV testing and used bivariate and multivariable analyses to assess its socio-demographic, behavioral, and psychosocial correlates. We found that the majority (55 %) of male clients of FSW in Tijuana, Mexico had never had an HIV test and the prevalence of HIV testing within the past year was low (9 %). In multivariable analyses, significant correlates of having ever tested for HIV were higher age, higher HIV knowledge score, lower sexual compulsiveness score, lower misogynistic attitudes score, having a condom break during sex with a FSW, and higher frequency of sex with a FSW while she was high. Our findings represent an important starting point for developing effective interventions to address the need to promote HIV testing among this population.

  5. Measuring Gratitude: A Comparative Validation of the Dutch Gratitude Questionnaire (GQ6 and Short Gratitude, Resentment, and Appreciation Test (SGRAT

    Directory of Open Access Journals (Sweden)

    Lilian Jans-Beken

    2015-05-01

    Full Text Available The aim of this article was to validate and compare the Dutch translations of the Gratitude Questionnaire (GQ6 and the Short Gratitude, Resentment, and Appreciation Test (SGRAT in an adult general population sample. In an online survey, 706 respondents ('M 'age = 44, 'SD 'age = 14 completed Dutch versions of the GQ6, the SGRAT, the Satisfaction With Life Scale (SWLS and the Positive Affect and Negative Affect Schedule (PANAS. At six week follow-up, 440 (62% of them ('M' age = 46, 'SD' age = 14 again completed the GQ6-NL and SGRAT-NL. Parallel analyses, exploratory factor analyses and confirmatory factor analyses revealed and confirmed one factor for the GQ6-NL, and three factors for the SGRAT-NL. Internal consistency indices of the GQ6-NL and of the SGRAT-NL were satisfactory. Both questionnaires demonstrated good test-retest reliability. Regression analyses showed, for the total scores on both gratitude questionnaires, positive associations with the SWLS and the Positive Affect Scale, and negative associations with the Negative Affect Scale. The results support the validity of the Dutch GQ6 and SGRAT. These questionnaires can be used to conduct further research of the grateful disposition in Dutch speaking individuals and groups.

  6. Interplay of short-range correlations and nuclear symmetry energy in hard-photon production from heavy-ion reactions at Fermi energies

    Science.gov (United States)

    Yong, Gao-Chan; Li, Bao-An

    2017-12-01

    Within an isospin- and momentum-dependent transport model for nuclear reactions at intermediate energies, we investigate the interplay of the nucleon-nucleon short-range correlations (SRCs) and nuclear symmetry energy Esym(ρ ) on hard-photon spectra in collisions of several Ca isotopes on 112Sn and 124Sn targets at a beam energy of 45 MeV/nucleon. It is found that over the whole spectra of hard photons studied, effects of the SRCs overwhelm those owing to the Esym(ρ ) . The energetic photons come mostly from the high-momentum tails (HMTs) of single-nucleon momentum distributions in the target and projectile. Within the neutron-proton dominance model of SRCs based on the consideration that the tensor force acts mostly in the isosinglet and spin-triplet nucleon-nucleon interaction channel, there are equal numbers of neutrons and protons, thus a zero isospin asymmetry in the HMTs. Therefore, experimental measurements of the energetic photons from heavy-ion collisions at Fermi energies have the great potential to help us better understand the nature of SRCs without any appreciable influence by the uncertain Esym(ρ ) . These measurements will be complementary to but also have some advantages over the ongoing and planned experiments using hadronic messengers from reactions induced by high-energy electrons or protons. Because the underlying physics of SRCs and Esym(ρ ) are closely correlated, a better understanding of the SRCs will, in turn, help constrain the nuclear symmetry energy more precisely in a broad density range.

  7. A correlation linking the predicted mean vote and the mean thermal vote based on an investigation on the human thermal comfort in short-haul domestic flights.

    Science.gov (United States)

    Giaconia, Carlo; Orioli, Aldo; Di Gangi, Alessandra

    2015-05-01

    The results of an experimental investigation on the human thermal comfort inside the cabin of some Airbus A319 aircrafts during 14 short-haul domestic flights, linking various Italian cities, are presented and used to define a correlation among the predicted mean vote (PMV), a procedure which is commonly used to assess the thermal comfort in inhabited environments, and the equivalent temperature and mean thermal vote (MTV), which are the parameters suggested by the European Standard EN ISO 14505-2 for the evaluation of the thermal environment in vehicles. The measurements of the radiant temperature, air temperature and relative humidity during flights were performed. The air temperature varied between 22.2 °C and 26.0 °C; the relative humidity ranged from 8.7% to 59.2%. The calculated values of the PMV varied from -0.16 to 0.90 and were confirmed by the answers of the passengers. The equivalent temperature was evaluated using the equations of Fanger or on the basis of the values of the skin temperature measured on some volunteers. The correlation linking the thermal sensation scales and zones used by the PMV and the MTV resulted quite accurate because the minimum value of the absolute difference between such environmental indexes equalled 0.0073 and the maximum difference did not exceed the value of 0.0589. Even though the equivalent temperature and the MTV were specifically proposed to evaluate the thermal sensation in vehicles, their use may be effectively extended to the assessment of the thermal comfort in airplanes or other occupied places. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  8. Annual and short-term variability in primary productivity by phytoplankton and correlated abiotic factors in the Jurumirim Reservoir (São Paulo, Brazil

    Directory of Open Access Journals (Sweden)

    R. Henry

    Full Text Available The annual variability of the photosynthetic production (PP by phytoplankton in the lacustrine zone of the Jurumirim Reservoir (São Paulo, Brazil was evaluated in a three-year study to identify recurrent patterns and their causes. Variability in PP was measured daily during two periods of the year (the dry and rainy seasons. An analysis of the PP data failed to identify a recurrent pattern, since the PP values showed no correlation with hydrological factors (rainfall, water level and discharge, and washout nor, apparently, with the water’s nutritional conditions. A principal component analysis revealed that the PP and assimilation ratio were higher when the PO4(3- and N-NH4+ contents were low and the Z EU/Z MIX ratios were at their highest. Areal primary productivity can be predicted based on the ratio between the maximum volumetric productivity and the coefficient of vertical extinction of light. However, the biomass integrated for Z EU was a poor predictor of areal primary productivity. No correlation was found between water temperature and areal and maximum volumetric productivity. Thus, the three-year PP study indicated that the variability pattern is typically chaotic. As for the short-term measurements, the PP was found to be higher in the dry season than in the rainy, although both seasons showed an areal PP variability of 35 to 40%. This pattern was attributed to the daily variation in the nutritional conditions and the magnitude of light penetrating through the water, combined with the mixing of phytoplanktonic cells. A comment about the relationship between primary production by phytoplankton and fish yield is also briefly discussed here.

  9. Recovery of leaf elongation during short term osmotic stress correlates with osmotic adjustment and cell turgor restoration in different durum wheat cultivars

    International Nuclear Information System (INIS)

    Mahdid, M.

    2014-01-01

    In order to investigate the responses of leaf elongation rate (LER), turgor and osmotic adjustment (OA) during a short-term stress (7 hours) imposed by PEG6000 and a recovery phase, three durum wheat (Triticum durum L.) varieties (Inrat; MBB; and OZ ) were grown in aerated nutrient solutions. Leaf elongation kinetics of leaf 3 was estimated using LVDT. Turgor was estimated using a cell pressure probe; osmotic potential as well as total sugars and potassium (K+) concentrations were estimated from expressed sap of elongation zone. Growth recovered rapidly and then stabilised at a lower value. A significant difference was found in % recovery of LER between the varieties. The cessation of growth after stress coincided with a decrease in turgor followed by a recovery period reaching control values in MBB and Inrat. A strong correlation (R2 = 0.83) between the reduction in turgor (turgor) and % recovery of LER was found at 7 hours after stress. The difference in the partial recovery of LER between varieties was thus related to the capacity of partial turgor recovery. Partial turgor recovery is associated with sugar or K+ based OA which indicates its importance in maintaining high LER values under water deficit. (author)

  10. Long-Term and Short-Term Effects of Hemodialysis on Liver Function Evaluated Using the Galactose Single-Point Test

    Directory of Open Access Journals (Sweden)

    Yi-Chou Hou

    2014-01-01

    Full Text Available Aim. The galactose single-point (GSP test assesses functioning liver mass by measuring the galactose concentration in the blood 1 hour after its administration. The purpose of this study was to investigate the impact of hemodialysis (HD on short-term and long-term liver function by use of GSP test. Methods. Seventy-four patients on maintenance HD (46 males and 28 females, 60.38 ± 11.86 years with a mean time on HD of 60.77 ± 48.31 months were studied. The GSP values were compared in two groups: (1 before and after single session HD, and (2 after one year of maintenance HD. Results. Among the 74 HD patient, only the post-HD Cr levels and years on dialysis were significantly correlated with GSP values (r=0.280, P<0.05 and r=-0.240, P<0.05, resp.. 14 of 74 patients were selected for GSP evaluation before and after a single HD session, and the hepatic clearance of galactose was similar (pre-HD 410 ± 254 g/mL, post-HD 439 ± 298 g/mL, P=0.49. GSP values decreased from 420.20 ± 175.26 g/mL to 383.40 ± 153.97 g/mL after 1 year maintenance HD in other 15 patients (mean difference: 19.00 ± 37.66 g/mL, P<0.05. Conclusions. Patients on maintenance HD for several years may experience improvement of their liver function. However, a single HD session does not affect liver function significantly as assessed by the GSP test. Since the metabolism of galactose is dependent on liver blood flow and hepatic functional mass, further studies are needed.

  11. Correlation of finite element free vibration predictions using random vibration test data. M.S. Thesis - Cleveland State Univ.

    Science.gov (United States)

    Chambers, Jeffrey A.

    1994-01-01

    Finite element analysis is regularly used during the engineering cycle of mechanical systems to predict the response to static, thermal, and dynamic loads. The finite element model (FEM) used to represent the system is often correlated with physical test results to determine the validity of analytical results provided. Results from dynamic testing provide one means for performing this correlation. One of the most common methods of measuring accuracy is by classical modal testing, whereby vibratory mode shapes are compared to mode shapes provided by finite element analysis. The degree of correlation between the test and analytical mode shapes can be shown mathematically using the cross orthogonality check. A great deal of time and effort can be exhausted in generating the set of test acquired mode shapes needed for the cross orthogonality check. In most situations response data from vibration tests are digitally processed to generate the mode shapes from a combination of modal parameters, forcing functions, and recorded response data. An alternate method is proposed in which the same correlation of analytical and test acquired mode shapes can be achieved without conducting the modal survey. Instead a procedure is detailed in which a minimum of test information, specifically the acceleration response data from a random vibration test, is used to generate a set of equivalent local accelerations to be applied to the reduced analytical model at discrete points corresponding to the test measurement locations. The static solution of the analytical model then produces a set of deformations that once normalized can be used to represent the test acquired mode shapes in the cross orthogonality relation. The method proposed has been shown to provide accurate results for both a simple analytical model as well as a complex space flight structure.

  12. Road and rail traffic noise induce comparable extra-aural effects as revealed during a short-term memory test

    Directory of Open Access Journals (Sweden)

    Eugen Gallasch

    2016-01-01

    Full Text Available To examine extraaural effects as induced by 20 min of road (ROAD and 20 min of rail (RAIL traffic noise with same loudness (75 dBA, a laboratory study was carried out. The study (N = 54 consisted of 28 high and 26 low-annoyed healthy individuals as determined by a traffic annoyance test. To control attention, all individuals performed a nonauditory short-term memory test during the noise exposures. A within-subject design, with phases of ROAD, RAIL, and CALM (memory test only, alternated by phases of rest, was defined. Heart rate (HR, systolic blood pressure (sBP, total peripheral resistance (TPR, as well as three autonomic variables, preejection period (PEP, 0.15–0.4 Hz high-frequency component of HR variability (HF, and salivary stress biomarker alpha amylase (sAA were measured. In relation to CALM, HR increased (RAIL +2.1%, ROAD +2.5%, sBP tended to increase against the end of noise exposure, PEP decreased (RAIL −0.7%, ROAD −0.8%, HF decreased (RAIL −3.4%, ROAD −2.9%, and sAA increased (RAIL +78%, ROAD +69%. No differences were found between RAIL and ROAD, indicating that both noise stressors induced comparable extraaural effects. Factor annoyance showed significant during CALM. Here a reduced sympathetic drive (higher PEP values combined with an increased vascular tone (higher TPR values was found at the high-annoyed subgroup.

  13. Correlation of single-breath count test and neck flexor muscle strength with spirometry in myasthenia gravis.

    Science.gov (United States)

    Elsheikh, Bakri; Arnold, W David; Gharibshahi, Shahram; Reynolds, Jerold; Freimer, Miriam; Kissel, John T

    2016-01-01

    Although formal spirometry is the gold standard for monitoring respiratory function in patients with myasthenia gravis (MG), such testing is often delayed or unavailable. There is a need for a simple bedside test that can accurately measure respiratory function. We conducted a prospective, cross-sectional, single-blind study in adults with acetylcholine receptor antibody positive MG. Participants performed the single breath count test (SBCT) and underwent manual muscle strength testing, and a respiratory therapist performed spirometry blinded to SBCT and strength results. Thirty-one patients, aged 57 ± 19 years participated. SBCT showed significant correlations with forced vital capacity (FVC), negative inspiratory force, and neck flexor strength (P strength (P = 0.02) but no correlation with shoulder abductor strength. These data suggest that the SBCT and neck flexor strength testing are valuable tools for bedside assessment of respiratory function in MG patients. © 2015 Wiley Periodicals, Inc.

  14. Automated Scoring of Short-Answer Open-Ended GRE® Subject Test Items. ETS GRE® Board Research Report No. 04-02. ETS RR-08-20

    Science.gov (United States)

    Attali, Yigal; Powers, Don; Freedman, Marshall; Harrison, Marissa; Obetz, Susan

    2008-01-01

    This report describes the development, administration, and scoring of open-ended variants of GRE® Subject Test items in biology and psychology. These questions were administered in a Web-based experiment to registered examinees of the respective Subject Tests. The questions required a short answer of 1-3 sentences, and responses were automatically…

  15. Morpho-Functional 1H-MRI of the Lung in COPD: Short-Term Test-Retest Reliability.

    Directory of Open Access Journals (Sweden)

    Bertram J Jobst

    Full Text Available Non-invasive end-points for interventional trials and tailored treatment regimes in chronic obstructive pulmonary disease (COPD for monitoring regionally different manifestations of lung disease instead of global assessment of lung function with spirometry would be valuable. Proton nuclear magnetic resonance imaging (1H-MRI allows for a radiation-free assessment of regional structure and function. The aim of this study was to evaluate the short-term reproducibility of a comprehensive morpho-functional lung MRI protocol in COPD.20 prospectively enrolled COPD patients (GOLD I-IV underwent 1H-MRI of the lung at 1.5T on two consecutive days, including sequences for morphology, 4D contrast-enhanced perfusion, and respiratory mechanics. Image quality and COPD-related morphological and functional changes were evaluated in consensus by three chest radiologists using a dedicated MRI-based visual scoring system. Test-retest reliability was calculated per each individual lung lobe for the extent of large airway (bronchiectasis, wall thickening, mucus plugging and small airway abnormalities (tree in bud, peripheral bronchiectasis, mucus plugging, consolidations, nodules, parenchymal defects and perfusion defects. The presence of tracheal narrowing, dystelectasis, pleural effusion, pulmonary trunk ectasia, right ventricular enlargement and, finally, motion patterns of diaphragma and chest wall were addressed.Median global scores [10(Q1:8.00;Q3:16.00 vs.11(Q1:6.00;Q3:15.00] as well as category subscores were similar between both timepoints, and kappa statistics indicated "almost perfect" global agreement (ĸ = 0.86, 95%CI = 0.81-0.91. Most subscores showed at least "substantial" agreement of MRI1 and MRI2 (ĸ = 0.64-1.00, whereas the agreement for the diagnosis of dystelectasis/effusion (ĸ = 0.42, 95%CI = 0.00-0.93 was "moderate" and of tracheal abnormalities (ĸ = 0.21, 95%CI = 0.00-0.75 "fair". Most MRI acquisitions showed at least diagnostic quality at

  16. Precision test of many-body QED in the Be$^{+} 2p$ fine structure doublet using short-lived isotopes

    CERN Document Server

    Nörtershäuser, Wilfried; Krieger, Andreas; Pachucki, Krzysztof; Puchalski, Mariusz; Blaum, Klaus; Bissell, Mark L; Frömmgen, Nadja; Hammen, Michael; Kowalska, Magdalena; Krämer, Jörg; Kreim, Kim; Neugart, Rainer; Neyens, Gerda; Sánchez, Rodolfo; Yordanov, Deyan T

    2015-01-01

    Absolute transition frequencies of the $2s\\; ^2{\\rm S}_{1/2} \\rightarrow 2p\\;^2\\mathrm{P}_{1/2,3/2}$ transitions in Be$^+$ were measured for the isotopes $^{7,9-12}$Be. The fine structure splitting of the $2p$ state and its isotope dependence are extracted and compared to results of \\textit{ab initio} calculations using explicitly correlated basis functions, including relativistic and quantum electrodynamics effects at the order of $m \\alpha^6$ and $m \\alpha^7 \\ln \\alpha$. Accuracy has been improved in both the theory and experiment by 2 orders of magnitude, and good agreement is observed. This represents one of the most accurate tests of quantum electrodynamics for many-electron systems, being insensitive to nuclear uncertainties.

  17. Internal consistency, reliability, and temporal stability of the Oxford Happiness Questionnaire short-form: Test-retest data over two weeks

    OpenAIRE

    MCGUCKIN, CONOR

    2006-01-01

    PUBLISHED The Oxford Happiness Questionnaire short-form is a recently developed eight-item measure of happiness. This study evaluated the internal consistency reliability and test-retest reliability of the Oxford Happiness Questionnaire short-form among 55 Northern Irish undergraduate university students who completed the measure on two occasions separated by two weeks. Internal consistency of the measure on both occasions was satisfactory at both Time 1 (alpha = .62) and Time 2 (alpha = ....

  18. Use of cardio-diagnostics of D&K-TEST for individualizations of training process of skilled short track speed skaters high qualification

    Directory of Open Access Journals (Sweden)

    Kygayevskiy S.A.

    2009-10-01

    Full Text Available In the article possibilities of individualization of training process of short track speed skaters high qualification are resulted on the basis of influence of application of loadings of different orientation on the indexes of cardio-diagnostics of D&K-TEST. The influences of loadings of different physiological and metabolic orientation given about efficiency are resulted on the level of functional preparedness of short track speed skaters of high qualification.

  19. Generalized Frequency-Domain Correlator for Software GPS Receiver: Preliminary Test Results and Analysis (PREPRINT)

    National Research Council Canada - National Science Library

    Yang, Chun; Miller, Mikel; Nguyen, Thao; Akos, Dennis

    2006-01-01

    .... The use of a GFDC can offer several advantages. First, as a generalization of the FFT-implemented correlation with a block repetitive processing capability, it enables fast acquisition through simultaneous code delay and Doppler frequency search...

  20. Sacubitril/valsartan and short-term changes in the 6-minute walk test: A pilot study.

    Science.gov (United States)

    Beltrán, Paola; Palau, Patricia; Domínguez, Eloy; Faraudo, Mercedes; Núñez, Eduardo; Guri, Olga; Mollar, Anna; Sanchis, Juan; Bayés-Genís, Antoni; Núñez, Julio

    2018-02-01

    Impaired exercise capacity is the most disabling symptom in patients with heart failure with reduced ejection fraction (HFrEF). Despite sacubitril/valsartan showing reduced long-term morbidity and mortality over enalapril in HFrEF, its effects on short-term functional capacity remain uncertain. We sought to evaluate the effects of sacubitril/valsartan on a 30-day six-minute walk test in eligible patients with HFrEF. From November 1, 2016 to February 1, 2017, a total of 58 stable symptomatic patients with HFrEF were eligible for sacubitril/valsartan and underwent 6-MWT before and 30days after initiation of sacubitril/valsartan therapy. A mixed-effects model for repeated-measures was used to analyze the changes. Mean age was 70±11years. 72.4% males, 46.6% with ischemic heart disease, and 51.7% on NYHA functional class III were included. The mean (SD) values of baseline LVEF and 6MWT were 30±7%, and 300±89m, respectively. The median (IQR) of NT-proBNP at baseline was 2701pg/ml (1087-4200). Compared with baseline, the 6-MWT distance increased significantly at 30days by 13.9% (+∆=41.8m (33.4-50.2); psacubitril/valsartan was associated with an improvement in exercise tolerance in symptomatic patients with HFrEF. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  1. Development and Short-Range Testing of a 100 kW Side-Illuminated Millimeter-Wave Thermal Rocket

    Science.gov (United States)

    Bruccoleri, Alexander; Eilers, James A.; Lambot, Thomas; Parkin, Kevin

    2015-01-01

    The objective of the phase described here of the Millimeter-Wave Thermal Launch System (MTLS) Project was to launch a small thermal rocket into the air using millimeter waves. The preliminary results of the first MTLS flight vehicle launches are presented in this work. The design and construction of a small thermal rocket with a planar ceramic heat exchanger mounted along the axis of the rocket is described. The heat exchanger was illuminated from the side by a millimeter-wave beam and fed propellant from above via a small tank containing high pressure argon or nitrogen. Short-range tests where the rocket was launched, tracked, and heated with the beam are described. The rockets were approximately 1.5 meters in length and 65 millimeters in diameter, with a liftoff mass of 1.8 kilograms. The rocket airframes were coated in aluminum and had a parachute recovery system activated via a timer and Pyrodex. At the rocket heat exchanger, the beam distance was 40 meters with a peak power intensity of 77 watts per square centimeter. and a total power of 32 kilowatts in a 30 centimeter diameter circle. An altitude of approximately 10 meters was achieved. Recommendations for improvements are discussed.

  2. Disentangling Gratitude: A Theoretical and Psychometric Examination of the Gratitude Resentment and Appreciation Test-Revised Short (GRAT-RS).

    Science.gov (United States)

    Hammer, Joseph H; Brenner, Rachel E

    2017-07-14

    This study extended our theoretical and applied understanding of gratitude through a psychometric examination of the most popular multidimensional measure of gratitude, the Gratitude, Resentment, and Appreciation Test-Revised Short form (GRAT-RS). Namely, the dimensionality of the GRAT-RS, the model-based reliability of the GRAT-RS total score and 3 subscale scores, and the incremental evidence of validity for its latent factors were assessed. Dimensionality measures (e.g., explained common variance) and confirmatory factor analysis results with 426 community adults indicated that the GRAT-RS conformed to a multidimensional (bifactor) structure. Model-based reliability measures (e.g., omega hierarchical) provided support for the future use of the Lack of a Sense of Deprivation raw subscale score, but not for the raw GRAT-RS total score, Simple Appreciation subscale score, or Appreciation of Others subscale score. Structural equation modeling results indicated that only the general gratitude factor and the lack of a sense of deprivation specific factor accounted for significant variance in life satisfaction, positive affect, and distress. These findings support the 3 pillars of gratitude conceptualization of gratitude over competing conceptualizations, the position that the specific forms of gratitude are theoretically distinct, and the argument that appreciation is distinct from the superordinate construct of gratitude.

  3. Short time evaluation of metallic materials' fatigue potential combining destructive and non-destructive testing methods

    International Nuclear Information System (INIS)

    Starke, Peter; Wu, Haoran; Boller, Christian

    2015-01-01

    Fatigue of engineering structures is an issue from an engineering design point. The lifetime of materials being subject to repeated mechanical loads is limited. Different examples of failures and fateful air accidents have caused significant cost and claims to the operators as well as manufacturers in excess of fatalities. Criticality of failure increases with increasing age and the uncertainty of operational loads applied. In such a case a reassessment of a structural materials' condition is in big need should damage tolerance criteria still be met, being the essential ground rule for aeronautical structural design. It is therefore the challenging aim to use a metallic material's microstructure characterizing non-destructive testing (NDT) parameter or a combination of those as a parameter to be scanned over a defined surface of the component considered to more realistically characterize the damage condition and to use this information twofold: (a) to more precisely assess the structural component's residual life and (b) to feed the information recorded back into a specific database belonging to an approach named PHYBAL. The physically based fatigue life evaluation method (PHYBAL) is a short-time procedure for the evaluation of fatigue data based on a small number of fatigue tests performed on un-notched specimens only. This method significantly reduces the effort for experimentation in terms of time and cost by around 90 % and inhibits remarkable scientific as well as economic advantages. The paper highlights the high capability of PHYBAL as well as the suitability for assessing the residual life of aeronautical components also with respect to the application of this approach in the light of structural health monitoring issues.

  4. Benign tracheobronchial stenoses: changes in short-term and long-term pulmonary function testing after expandable metallic stent placement.

    Science.gov (United States)

    Gotway, Michael B; Golden, Jeffrey A; LaBerge, Jeanne M; Webb, W Richard; Reddy, Gautham P; Wilson, Mark W; Kerlan, Robert K; Gordon, Roy L

    2002-01-01

    To determine the short- and long-term improvement in airflow dynamics in patients undergoing tracheobronchial stent placement for benign airway stenoses. Twenty-two patients underwent 34 tracheal and/or bronchial stent placement procedures for benign airway stenoses and had the results of pulmonary function tests available. Stent placement indications included bronchomalacia after lung transplantation (n = 11), postintubation stenoses (n = 6), relapsing polychondritis (n = 2), and 1 each of tracheomalacia, tracheal compression, and histoplasmosis. Six patients underwent more than one stent placement procedure (range: 2-7 procedures). The mean forced expiratory volume in one second (FEV(1) ), forced expiratory flow rate in the midportion of the forced vital capacity curve (FEF(25-75) ), forced vital capacity, and peak flow (PF) rate obtained before stent placement were compared with those immediately after stent placement and with those measurements most remote from stent placement using the paired two-tailed test. All patients reported improved respiratory function immediately after stent placement. The mean FEV(1), FEF(25-75), and PF rate improved significantly (p stent placement. On long-term follow-up averaging 15 months after stent placement, these parameters declined despite patients' subjective sense of improvement. Segregating the population into transplant and nontransplant airway stenosis etiologies, however, FEF(25-75) and PF rate remained significantly improved (p = 0.045, p = 0.027, respectively), over the long term for the latter. FEV increased after subsequent stent placements for patients receiving multiple stents. Stent placement for benign tracheobronchial stenoses provides significant immediate improvement in airflow dynamics. Long-term improvement in airflow obstruction may be expected, and additional stent placements may further improve pulmonary function.

  5. Detection of endotoxins in radiopharmaceutical preparations. III. Limulus test assessment using radiopharmaceutical preparations; correlation with the rabbit pyrogen test

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, Y; Bahri, F; Bruneau, J; Dubuis, M; Dubuis, N; Merlin, L; Michaud, T; Peysson, S

    1986-01-01

    Experiments using 17 radiopharmaceuticals containing known amounts of added endotoxin show that none of them inhibits the pyrogenic reaction of the rabbit. Gelation of the Limulus amoebocyte lysate (LAL) is inhibited by 4 of them: colloidal erbium 169Er citrate, colloidal rhenium 186Re sulfide, colloidal technetium /sup 99m/Tc (Re) sulfide for liver scintigraphy and the colloidal technetium /sup 99m/Tc (Re) sulfide for lymphography. This inhibition is cancelled, either by dilution or after neutral pH adjustment. Both controls were performed on 313 batches of various radiopharmaceuticals, 95% of results were identical (93% negative, 2% positive). The remaining 5% correspond to positive LAL tests vs negative rabbit tests on the same batches. No negative LAL test vs positive rabbit test was observed.

  6. Full-scale locomotive dynamic crash testing and correlations : locomotive consist colliding with steel coil truck at grade crossing (test 3).

    Science.gov (United States)

    2011-09-01

    This report presents the test results and finite element correlations of a full-scale dynamic collision between a locomotive and a highway truck loaded with two heavy steel coils. The locomotive consist was moving at 58 miles per hour before it struc...

  7. Investigating the Correlation Between Pharmacy Student Performance on the Health Science Reasoning Test and a Critical Thinking Assignment.

    Science.gov (United States)

    Nornoo, Adwoa O; Jackson, Jonathan; Axtell, Samantha

    2017-03-25

    Objective. To determine whether there is a correlation between pharmacy students' scores on the Health Science Reasoning Test (HSRT) and their grade on a package insert assignment designed to assess critical thinking. Methods. The HSRT was administered to first-year pharmacy students during a critical-thinking course in the spring semester. In the same semester, a required package insert assignment was completed in a pharmacokinetics course. To determine whether there was a relationship between HSRT scores and grades on the assignment, a Spearman's rho correlation test was performed. Results. A very weak but significant positive correlation was found between students' grades on the assignment and their overall HSRT score (r=0.19, p critical-thinking skills in pharmacy students.

  8. Addenbrooke's cognitive examination III: diagnostic utility for mild cognitive impairment and dementia and correlation with standardized neuropsychological tests.

    Science.gov (United States)

    Matias-Guiu, Jordi A; Cortés-Martínez, Ana; Valles-Salgado, Maria; Rognoni, Teresa; Fernández-Matarrubia, Marta; Moreno-Ramos, Teresa; Matías-Guiu, Jorge

    2017-01-01

    Addenbrooke's Cognitive Examination III (ACE-III) is a screening test that was recently validated for diagnosing dementia. Since it assesses attention, language, memory, fluency, and visuospatial function separately, it may also be useful for general neuropsychological assessments. The aim of this study was to analyze the tool's ability to detect early stages of Alzheimer's disease and to examine the correlation between ACE-III scores and scores on standardized neuropsychological tests. Our study included 200 participants categorized as follows: 25 healthy controls, 48 individuals with subjective memory complaints, 47 patients with amnestic mild cognitive impairment and 47 mild Alzheimer's disease, and 33 patients with other neurodegenerative diseases. The ACE-III memory and language domains were highly correlated with the neuropsychological tests specific to those domains (Pearson correlation coefficient of 0.806 for total delayed recall on the Free and Cued Selective Reminding Test vs. 0.744 on the Boston Naming Test). ACE-III scores discriminated between controls and patients with amnestic mild cognitive impairment (AUC: 0.906), and between controls and patients with mild Alzheimer's disease (AUC: 0.978). Our results suggest that ACE-III is a useful neuropsychological test for assessing the cognitive domains of attention, language, memory, and visuospatial function. It also enables detection of Alzheimer's disease in early stages.

  9. Study of quantum spin correlations of relativistic electron pairs - Testing nonlocality of relativistic quantum mechanics

    International Nuclear Information System (INIS)

    Bodek, K.; Rozpędzik, D.; Zejma, J.; Caban, P.; Rembieliński, J.; Włodarczyk, M.; Ciborowski, J.; Enders, J.; Köhler, A.; Kozela, A.

    2013-01-01

    The Polish-German project QUEST aims at studying relativistic quantum spin correlations of the Einstein-Rosen-Podolsky-Bohm type, through measurement of the correlation function and the corresponding probabilities for relativistic electron pairs. The results will be compared to theoretical predictions obtained by us within the framework of relativistic quantum mechanics, based on assumptions regarding the form of the relativistic spin operator. Agreement or divergence will be interpreted in the context of non-uniqueness of the relativistic spin operator in quantum mechanics as well as dependence of the correlation function on the choice of observables representing the spin. Pairs of correlated electrons will originate from the Mo/ller scattering of polarized 15 MeV electrons provided by the superconducting Darmstadt electron linear accelerator S-DALINAC, TU Darmstadt, incident on a Be target. Spin projections will be determined using the Mott polarimetry technique. Measurements (starting 2013) are planned for longitudinal and transverse beam polarizations and different orientations of the beam polarization vector w.r.t. the Mo/ller scattering plane. This is the first project to study relativistic spin correlations for particles with mass

  10. A Statistical Test of Correlations and Periodicities in the Geological Records

    Science.gov (United States)

    Yabushita, S.

    1997-09-01

    Matsumoto & Kubotani argued that there is a positive and statistically significant correlation between cratering and mass extinction. This argument is critically examined by adopting a method of Ertel used by Matsumoto & Kubotani but by applying it more directly to the extinction and cratering records. It is shown that on the null-hypothesis of random distribution of crater ages, the observed correlation has a probability of occurrence of 13%. However, when large craters are excluded whose ages agree with the times of peaks of extinction rate of marine fauna, one obtains a negative correlation. This result strongly indicates that mass extinction are not due to accumulation of impacts but due to isolated gigantic impacts.

  11. Tests of a robust eddy correlation system for sensible heat flux

    Science.gov (United States)

    Blanford, J. H.; Gay, L. W.

    1992-03-01

    Sensible heat flux estimates from a simple, one-propeller eddy correlation system (OPEC) were compared with those from a sonic anemometer eddy correlation system (SEC). In accordance with similarity theory, the performance of the OPEC system improved with increasing height of the sensor above the surface. Flux totals from the two systems at sites with adequate fetch were in excellent agreement after frequency response corrections were applied. The propeller system appears suitable for long periods of unattended measurement. The sensible heat flux measurements can be combined with net radiation and soil heat flux measurements to estimate latent heat as a residual in the surface energy balance.

  12. Polarization correlations of 1S0 proton pairs as tests of Bell and Wigner inequalities

    NARCIS (Netherlands)

    Polachic, C.; Rangacharyulu, C.; van den Berg, A.M.; Hamieh, S.; Harakeh, M.N.; Hunyadi, M.D.; de Huu, M.A.; Wörtche, H.J.; Heyse, J.; Bäumer, C.; Frekers, D.; Rakers, S.

    2004-01-01

    We are investigating the feasibility of nuclear physics experiments designed to overcome the loopholes of observer-dependent reality and satisfying the counterfactuality condition. In a first approach, we have measured polarization correlations of proton pairs produced in 12C(d, 2He) and 1H(d, 2He)

  13. Polarization correlations of S-1(0) proton pairs as tests of hidden-variable theories

    NARCIS (Netherlands)

    Polachic, C; Rangacharyulu, C; van den Berg, AM; Hamieh, S; Harakeh, MN; Hunyadi, M; de Huu, MA; Wortche, HJ; Heyse, J; Baumer, C; Frekers, D; Brooke, JA; Busch, P

    2004-01-01

    We are investigating the feasibility of nuclear physics experiments designed to overcome the loopholes of observer-dependent reality and satisfying the counterfactuality condition. In a first approach, we have measured polarization correlations of S-1(0) proton pairs produced in C-12(d, He-2) and

  14. (e, 3e) Test on e–e correlations in helium

    Indian Academy of Sciences (India)

    £Present address: S.I.E.T., Dulehra Marg, Modipuram, Meerut 250 110, India ... A proper accounting of e–e correlation in the final state which contains three electrons in the field .... The results are however not very sensitive to its value. αb. , αc.

  15. Performance of Modified Test Statistics in Covariance and Correlation Structure Analysis under Conditions of Multivariate Nonnormality.

    Science.gov (United States)

    Fouladi, Rachel T.

    2000-01-01

    Provides an overview of standard and modified normal theory and asymptotically distribution-free covariance and correlation structure analysis techniques and details Monte Carlo simulation results on Type I and Type II error control. Demonstrates through the simulation that robustness and nonrobustness of structure analysis techniques vary as a…

  16. Testing a Model of Planck-Scale Quantum Geometry With Broadband Correlation of Colocated 40m Interferometers

    International Nuclear Information System (INIS)

    McCuller, Lee Patrick

    2015-01-01

    The Holometer is designed to test for a Planck diffractive-scaling uncertainty in long-baseline position measurements due to an underlying noncommutative geometry normalized to relate Black hole entropy bounds of the Holographic principle to the now-finite number of position states. The experiment overlaps two independent 40 meter optical Michelson interferometers to detect the proposed uncertainty as a common broadband length fluctuation. 150 hours of instrument cross-correlation data are analyzed to test the prediction of a correlated noise magnitude of 7·10 -21 m/√Hz with an effective bandwidth of 750kHz. The interferometers each have a quantum-limited sensitivity of 2.5·10 -18 m/√Hz, but their correlation with a time-bandwidth product of 4·10 11 digs between the noise floors in search for the covarying geometric jitter. The data presents an exclusion of 5 standard deviations for the tested model. This exclusion is defended through analysis of the calibration methods for the instrument as well as further sub shot noise characterization of the optical systems to limit spurious background-correlations from undermining the signal.

  17. A powerful nonparametric method for detecting differentially co-expressed genes: distance correlation screening and edge-count test.

    Science.gov (United States)

    Zhang, Qingyang

    2018-05-16

    Differential co-expression analysis, as a complement of differential expression analysis, offers significant insights into the changes in molecular mechanism of different phenotypes. A prevailing approach to detecting differentially co-expressed genes is to compare Pearson's correlation coefficients in two phenotypes. However, due to the limitations of Pearson's correlation measure, this approach lacks the power to detect nonlinear changes in gene co-expression which is common in gene regulatory networks. In this work, a new nonparametric procedure is proposed to search differentially co-expressed gene pairs in different phenotypes from large-scale data. Our computational pipeline consisted of two main steps, a screening step and a testing step. The screening step is to reduce the search space by filtering out all the independent gene pairs using distance correlation measure. In the testing step, we compare the gene co-expression patterns in different phenotypes by a recently developed edge-count test. Both steps are distribution-free and targeting nonlinear relations. We illustrate the promise of the new approach by analyzing the Cancer Genome Atlas data and the METABRIC data for breast cancer subtypes. Compared with some existing methods, the new method is more powerful in detecting nonlinear type of differential co-expressions. The distance correlation screening can greatly improve computational efficiency, facilitating its application to large data sets.

  18. Testing a Model of Planck-Scale Quantum Geometry With Broadband Correlation of Colocated 40m Interferometers

    Energy Technology Data Exchange (ETDEWEB)

    McCuller, Lee Patrick [Univ. of Chicago, IL (United States)

    2015-12-01

    The Holometer is designed to test for a Planck diffractive-scaling uncertainty in long-baseline position measurements due to an underlying noncommutative geometry normalized to relate Black hole entropy bounds of the Holographic principle to the now-finite number of position states. The experiment overlaps two independent 40 meter optical Michelson interferometers to detect the proposed uncertainty as a common broadband length fluctuation. 150 hours of instrument cross-correlation data are analyzed to test the prediction of a correlated noise magnitude of $7\\times10^{−21}$ m/$\\sqrt{\\rm Hz}$ with an effective bandwidth of 750kHz. The interferometers each have a quantum-limited sensitivity of $2.5\\times 10^{−18}$ m/$\\sqrt{\\rm Hz}$, but their correlation with a time-bandwidth product of $4\\times 10^{11}$ digs between the noise floors in search for the covarying geometric jitter. The data presents an exclusion of 5 standard deviations for the tested model. This exclusion is defended through analysis of the calibration methods for the instrument as well as further sub shot noise characterization of the optical systems to limit spurious background-correlations from undermining the signal.

  19. Correlating Dynamometer Testing to In-Use Fleet Results of Plug-In Hybrid Electric Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    John G. Smart; Sera White; Michael Duoba

    2009-05-01

    Standard dynamometer test procedures are currently being developed to determine fuel and electrical energy consumption of plug-in hybrid vehicles (PHEV). To define a repeatable test procedure, assumptions were made about how PHEVs will be driven and charged. This study evaluates these assumptions by comparing results of PHEV dynamometer testing following proposed procedures to actual performance of PHEVs operating in the US Department of Energy’s (DOE) North American PHEV Demonstration fleet. Results show PHEVs in the fleet exhibit a wide range of energy consumption, which is not demonstrated in dynamometer testing. Sources of variation in performance are identified and examined.

  20. HIV testing among social media-using Peruvian men who have sex with men: correlates and social context.

    Science.gov (United States)

    Krueger, Evan A; Chiu, ChingChe J; Menacho, Luis A; Young, Sean D

    2016-10-01

    HIV remains concentrated among men who have sex with men (MSM) in Peru, and homophobia and AIDS-related stigmas have kept the epidemic difficult to address. Gay self-identity has been associated with increased HIV testing, though this relationship has not been examined extensively. Social media use has been rapidly increasing in Peru, yet little is known about MSM social media users in Peru. This study sought to investigate the demographic, behavioral, and stigma-related factors associated with HIV testing among social media-using Peruvian MSM. Five hundred and fifty-six MSM from Lima and surrounding areas were recruited from social networking websites to complete a survey on their sexual risk behaviors. We examined the demographic and social correlates of HIV testing behavior among this sample. Younger age and non-gay identity were significantly associated with lower likelihood of getting tested in univariate analysis. After controlling for key behaviors and AIDS-related stigma, younger age remained significantly associated with decreased testing. Participants who engaged in discussions online about HIV testing were more likely to get tested, while AIDS-related stigma presented a significant barrier to testing. Stigma severity also varied significantly by sexual identity. Youth appear to be significantly less likely than older individuals to test for HIV. Among Peruvian MSM, AIDS-related stigma remains a strong predictor of willingness to get tested. Social media-based intervention work targeting Peruvian youth should encourage discussion around HIV testing, and must also address AIDS-related stigma.

  1. Correlates of STI testing among vocational school students in the Netherlands

    NARCIS (Netherlands)

    M.E.G. Wolfers (Mireille); G.J. Kok (Gerjo); J.P. Mackenbach (Johan); O. de Zwart (Onno)

    2010-01-01

    textabstractBackground. Adolescents are at risk for acquiring sexually transmitted infections (STIs). However, test rates among adolescents in the Netherlands are low and effective interventions that encourage STI testing are scarce. Adolescents who attend vocational schools are particularly at risk

  2. Numerical CFD Simulation and Test Correlation in a Flight Project Environment

    Science.gov (United States)

    Gupta, K. K.; Lung, S. F.; Ibrahim, A. H.

    2015-01-01

    This paper presents detailed description of a novel CFD procedure and comparison of its solution results to that obtained by other available CFD codes as well as actual flight and wind tunnel test data pertaining to the GIII aircraft, currently undergoing flight testing at AFRC.

  3. Correlates of Illicit Drug Use Among Indigenous Peoples in Canada: A Test of Social Support Theory.

    Science.gov (United States)

    Cao, Liqun; Burton, Velmer S; Liu, Liu

    2018-02-01

    Relying on a national stratified random sample of Indigenous peoples aged 19 years old and above in Canada, this study investigates the correlates of illicit drug use among Indigenous peoples, paying special attention to the association between social support measures and illegal drug use. Results from multivariate logistical regression show that measures of social support, such as residential mobility, strength of ties within communities, and lack of timely counseling, are statistically significant correlates of illicit drug use. Those identifying as Christian are significantly less likely to use illegal drugs. This is the first nationwide analysis of the illicit drug usage of Indigenous peoples in Canada. The results are robust because we have controlled for a range of comorbidity variables as well as a series of sociodemographic variables. Policy implications from these findings are discussed.

  4. An Ecological Study of Anterior Cruciate Ligament Reconstruction, Part 2: Functional Performance Tests Correlate With Return-to-Sport Outcomes.

    Science.gov (United States)

    McGrath, Timothy M; Waddington, Gordon; Scarvell, Jennie M; Ball, Nick; Creer, Rob; Woods, Kevin; Smith, Damian; Adams, Roger

    2017-02-01

    Additional high-quality prospective studies are needed to better define the objective criteria used in relation to return-to-sport decisions after anterior cruciate ligament (ACL) reconstruction in active populations. To investigate prospectively the relationship between functional performance test results at 24 weeks postoperative and return-to-sport activity (Tegner activity score) at 12 and 24 months, respectively, after synthetic (ligament advanced reinforcement system [LARS]) and autograft (doubled semitendinosus/gracilis [2ST/2GR]) ACL reconstructions. Case series; Level of evidence, 4. A total of 64 patients who underwent ACL reconstruction (32 LARS, 32 2ST/2GR autograft; mean age, 27.9 years; body mass index [BMI], 24.9 kg/m 2 ) were assessed preoperatively and at staged intervals postoperatively up to 24 weeks for isokinetic testing of quadriceps and hamstring average power per repetition at 60 deg/s and 180 deg/s, a battery of hop tests, peak vertical ground-reaction force (vGRF), and time to peak vGRF (in seconds) during a step- and jump-down task onto a force platform and peak speed (m/s) using a global positioning system (GPS unit) during a running task. A cohort of 32 healthy matched participants (mean age, 26.31 years; BMI, 25.7 kg/m 2 ) were also tested to act as reference. Pearson correlation was calculated to assess correlation of each performance measure at 24 weeks postoperative with activity outcomes (Tegner score) at 12 and 24 months. The strongest correlation between physical performance tests and return-to-sport outcomes was observed with peak speed during running. Large correlations were also observed for hamstring isokinetic power and hop test for distance. Moderate correlations were observed for timed hop, peak vGRF during a jump-down task, and quadriceps isokinetic power. No statistical correlations were observed for time to peak vGRF during a step-down and jump-down task as well as peak vGRF during a step-down task. When the performance

  5. High-resolution computed tomography in silicosis: correlation with chest radiography and pulmonary function tests

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Agnaldo Jose [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Pedro Ernesto Univ. Hospital. Dept. of Respiratory Function]. E-mail: phel.lop@uol.com.br; Mogami, Roberto; Capone, Domenico; Jansen, Jose Manoel [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). School of Medical Sciences; Tessarollo, Bernardo [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Dept. of Radiology and Diagnostic Image; Melo, Pedro Lopes de [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Inst. of Biology

    2008-05-15

    Objective: To correlate tomographic findings with pulmonary function findings, as well as to compare chest X-ray findings with high-resolution computed tomography (HRCT) findings, in patients with silicosis. Methods: A cross-sectional study was conducted in 44 non-smoking patients without a history of tuberculosis. Chest X-ray findings were classified according to the International Labour Organization recommendations. Using a semiquantitative system, the following HRCT findings were measured: the full extent of pulmonary involvement; parenchymal opacities; and emphysema. Spirometry and forced oscillation were performed. Pulmonary volumes were evaluated using the helium dilution method, and diffusing capacity of the lung for carbon monoxide was assessed. Results: Of the 44 patients studied, 41 were male. The mean age was 48.4 years. There were 4 patients who were classified as category 0 based on X-ray findings and as category 1 based on HRCT findings. Using HRCT scans, we identified progressive massive fibrosis in 33 patients, compared with only 23 patients when X-rays were used. Opacity score was found to correlate most closely with airflow, DLCO and compliance. Emphysema score correlated inversely with volume, DLCO and airflow. In this sample of patients presenting a predominance of large opacities (75% of the individuals), the deterioration of pulmonary function was associated with the extent of structural changes. Conclusions: In the early detection of silicosis and the identification of progressive massive fibrosis, HRCT scans are superior to X-rays. (author)

  6. High-resolution computed tomography in silicosis: correlation with chest radiography and pulmonary function tests

    International Nuclear Information System (INIS)

    Lopes, Agnaldo Jose; Mogami, Roberto; Capone, Domenico; Jansen, Jose Manoel; Tessarollo, Bernardo; Melo, Pedro Lopes de

    2008-01-01

    Objective: To correlate tomographic findings with pulmonary function findings, as well as to compare chest X-ray findings with high-resolution computed tomography (HRCT) findings, in patients with silicosis. Methods: A cross-sectional study was conducted in 44 non-smoking patients without a history of tuberculosis. Chest X-ray findings were classified according to the International Labour Organization recommendations. Using a semiquantitative system, the following HRCT findings were measured: the full extent of pulmonary involvement; parenchymal opacities; and emphysema. Spirometry and forced oscillation were performed. Pulmonary volumes were evaluated using the helium dilution method, and diffusing capacity of the lung for carbon monoxide was assessed. Results: Of the 44 patients studied, 41 were male. The mean age was 48.4 years. There were 4 patients who were classified as category 0 based on X-ray findings and as category 1 based on HRCT findings. Using HRCT scans, we identified progressive massive fibrosis in 33 patients, compared with only 23 patients when X-rays were used. Opacity score was found to correlate most closely with airflow, DLCO and compliance. Emphysema score correlated inversely with volume, DLCO and airflow. In this sample of patients presenting a predominance of large opacities (75% of the individuals), the deterioration of pulmonary function was associated with the extent of structural changes. Conclusions: In the early detection of silicosis and the identification of progressive massive fibrosis, HRCT scans are superior to X-rays. (author)

  7. Energy prices and agricultural commodity prices: Testing correlation using copulas method

    International Nuclear Information System (INIS)

    Koirala, Krishna H.; Mishra, Ashok K.; D'Antoni, Jeremy M.; Mehlhorn, Joey E.

    2015-01-01

    The linear relationships between energy prices and prices for agricultural commodities such as corn and soybeans may have been affected, over the last several years, by policy legislations in the farm sector, the Energy Independence and Security Act of 2007, and the Renewable Fuel Standard Program for 2014. Using high-frequency data and newer methodology, this study investigates dependence between agricultural commodity futures prices and energy futures prices. Results reveal that agricultural commodity and energy future prices are highly correlated and exhibit positive and significant relationship. Findings from this study highlight that an increase in energy price increases the price of agricultural commodities. - Highlights: • Energy policy mandates production of 15 billion gallons of corn ethanol by 2015. • Energy-intensive agriculture has a link between energy sector and crop production costs. • We investigate correlation between energy prices and agricultural commodity prices. • Agricultural commodity and energy future prices are highly correlated. • Increase in energy price increases the price of agricultural commodity

  8. A generalized Levene's scale test for variance heterogeneity in the presence of sample correlation and group uncertainty.

    Science.gov (United States)

    Soave, David; Sun, Lei

    2017-09-01

    We generalize Levene's test for variance (scale) heterogeneity between k groups for more complex data, when there are sample correlation and group membership uncertainty. Following a two-stage regression framework, we show that least absolute deviation regression must be used in the stage 1 analysis to ensure a correct asymptotic χk-12/(k-1) distribution of the generalized scale (gS) test statistic. We then show that the proposed gS test is independent of the generalized location test, under the joint null hypothesis of no mean and no variance heterogeneity. Consequently, we generalize the recently proposed joint location-scale (gJLS) test, valuable in settings where there is an interaction effect but one interacting variable is not available. We evaluate the proposed method via an extensive simulation study and two genetic association application studies. © 2017 The Authors Biometrics published by Wiley Periodicals, Inc. on behalf of International Biometric Society.

  9. Short-interval test-retest interrater reliability of the Dutch version of the structured clinical interview for DSM-IV personality disorders (SCID-II)

    NARCIS (Netherlands)

    Weertman, A; ArntZ, A; Dreessen, L; van Velzen, C; Vertommen, S

    2003-01-01

    This study examined the short-interval test-retest reliability of the Structured Clinical Interview (SCID-II: First, Spitzer, Gibbon, & Williams, 1995) for DSM-IV personality disorders (PDs). The SCID-II was administered to 69 in- and outpatients on two occasions separated by 1 to 6 weeks. The

  10. Water syphon test and gastrooesophageal reflux during childhood (correlation with the clinical findings and oesophageal manometry)

    Energy Technology Data Exchange (ETDEWEB)

    Fotter, R.; Hoellwarth, M.

    1981-07-01

    The water syphon test is a simple and easily performed method for demonstrating gastro-oesophageal reflux with a high degree of reliability. It is carried out following a conventional barium swallow. Compared with clinical findings and oesophageal manometry, the water syphon test is very reliable for demonstrating gastro-oesophageal reflux during childhood. Prolonged irradiation in order to see spontaneous reflux becomes unnecessary. This results in a significant reduction in radiation dose. Barium swallow and the water syphon test are the most useful initial examinations in children with symptoms which suggest reflux.

  11. Numerical development of a new correlation between biaxial fracture strain and material fracture toughness for small punch test

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Pradeep [Homi Bhabha National Institute, Anushaktinagar, Mumbai 400094 (India); Dutta, B.K., E-mail: bijon.dutta@gmail.com [Homi Bhabha National Institute, Anushaktinagar, Mumbai 400094 (India); Chattopadhyay, J. [Homi Bhabha National Institute, Anushaktinagar, Mumbai 400094 (India); Reactor Safety Division, Bhabha Atomic Research Centre, Mumbai 400085 (India)

    2017-04-01

    The miniaturized specimens are used to determine mechanical properties of the materials, such as yield stress, ultimate stress, fracture toughness etc. Use of such specimens is essential whenever limited quantity of material is available for testing, such as aged/irradiated materials. The miniaturized small punch test (SPT) is a technique which is widely used to determine change in mechanical properties of the materials. Various empirical correlations are proposed in the literature to determine the value of fracture toughness (J{sub IC}) using this technique. bi-axial fracture strain is determined using SPT tests. This parameter is then used to determine J{sub IC} using available empirical correlations. The correlations between J{sub IC} and biaxial fracture strain quoted in the literature are based on experimental data acquired for large number of materials. There are number of such correlations available in the literature, which are generally not in agreement with each other. In the present work, an attempt has been made to determine the correlation between biaxial fracture strain (ε{sub qf}) and crack initiation toughness (J{sub i}) numerically. About one hundred materials are digitally generated by varying yield stress, ultimate stress, hardening coefficient and Gurson parameters. Such set of each material is then used to analyze a SPT specimen and a standard TPB specimen. Analysis of SPT specimen generated biaxial fracture strain (ε{sub qf}) and analysis of TPB specimen generated value of J{sub i}. A graph is then plotted between these two parameters for all the digitally generated materials. The best fit straight line determines the correlation. It has been also observed that it is possible to have variation in J{sub i} for the same value of biaxial fracture strain (ε{sub qf}) within a limit. Such variation in the value of J{sub i} has been also ascertained using the graph. Experimental SPT data acquired earlier for three materials were then used to get J

  12. Correlation between subjective and objective hearing tests after unilateral and bilateral cochlear implantation

    NARCIS (Netherlands)

    Ramakers, Geerte G.J.; Smulders, Yvette E.; Van Zon, Alice; van Zanten, Gijsbert A.; Grolman, Wilko; Stegeman, Inge

    2017-01-01

    Background: There are many methods for assessing hearing performance after cochlear implantation. Standard evaluations often encompass objective hearing tests only, while patients' subjective experiences gain importance in today's healthcare. The aim of the current study was to analyze the

  13. Safety of railroad passenger vehicle dynamics : OMNISIM simulation and test correlations for passenger rail cars

    Science.gov (United States)

    2002-07-01

    The purpose of the work is to validate the safety assessment methodology previously developed for passenger rail vehicle dynamics, which requires the application of simulation tools as well as testing of vehicles under different track scenarios. This...

  14. Test of rotating wheel system for measuring correlated α-decay

    International Nuclear Information System (INIS)

    Wu Xiaolei; Gan Zaiguo; Guo Junsheng; Fan Hongmei; Qin Zhi

    2005-01-01

    A rotating-wheel set-up used for measuring and studying the heavy nuclei with α-decay was built. This system was tested experimentally by using ion-beam from SFC. The test results prove that this set-up was useful and reliable. It provides simple and effective equipment and technique to synthesize and identify new nuclides of Z=107 in the near future. (authors)

  15. Correlation between the immunological condition and the results of immunoenzymatic tests in diagnosing infectious mononucleosis.

    Science.gov (United States)

    Tamaro, Giorgio; Donato, Michela; Princi, Tanja; Parco, Sergio

    2009-04-01

    A symptom-based diagnosis of infectious mononucleosis is not sufficiently accurate, since some clinical symptoms of infectious mononucleosis are also detected in other virally induced diseases. Moreover, not all patients suffering from infectious mononucleosis show circulating atypical lymphocytes, which are considered characteristic of this disease. Therefore, when this disorder is suspected, serum analyses are carried out to detect the presence of certain immunoglobulins associated with infectious mononucleosis in the patient's blood. The aim of this study was to evaluate the sensitivity and the specificity of a rapid test detecting heterophil antibodies in diagnosing infectious mononucleosis in a paediatric population. We considered 163 paediatric patients with suspected infectious mononucleosis and we tested their serums to detect heterophil antibodies (using an inexpensive and rapid test) and specific immunoglobulins directed against Epstein-Barr virus (EBV) (these assays are known to be characterized by high sensitivity and specificity, but are more expensive and time-consuming). By comparing the results of the rapid test with those of the other assays, we found that the sensitivity of the first test was 61.8%, whereas its specificity was sufficiently high (about 90%). We show that, in paediatric patients, the detection of heterophil antibodies is not a very sensitive test, therefore the determination of immunoglobulins against specific antigens of EBV is recommended.

  16. Correlation of six minute walk test with spirometric indices in chronic obstructive pulmonary disease patients: A tertiary care hospital experience

    Directory of Open Access Journals (Sweden)

    Abhijit Kundu

    2015-01-01

    Full Text Available Background: Six-minute walk test (6MWT is a simple, objective, reproducible test which correlated well with different spirometric indices, and thus able to predict severity of chronic obstructive pulmonary disease (COPD and can replace spirometry in resource poor set-up. Aims and Objectives: To find out correlation between spirometric indices (forced expiratory volume in 1 s (FEV 1 , forced vital capacity (FVC, and peak expiratory flow rate (PEFR and 6-minute walk distance (6MWD in COPD patients, and thus to assess whether 6MWT can replace spirometry. Settings and Design: Institution based cross-sectional observational study. Materials and Methods: Eighty patients of COPD (diagnosis confirmed by Global Initiative for Chronic Obstructive Lung Disease (GOLD 2010 criteria were enrolled for the study after applying exclusion criteria. All patients underwent spirometric measurement of FEV 1 , FVC, PEFR, and ratio of FEV 1 and FVC and test repeated after bronchodilation by 200-400 μg of salbutamol. 6MWT was performed following American Thoracic Society (ATS protocol of 6MWT and distance was measured in meters. Results: We found significant linear correlation of 6MWT with post-FEV 1 (r = 0.478, P < 0.001, post-FVC (r = 0.454, P < 0.001, and post-PEFR (r = 0.408, P < 0.001, but no correlation with FEV 1 /FVC (r = 0.250, P = 0.025. We also found significant correlation of 6MWT with BODE (body mass index (BMI, airway obstruction, dyspnea, and exercise capacity index (r = −0.419, P < 0.001. Conclusions: 6MWT can be a useful replacement of spirometry in assessment of severity of COPD.

  17. Experiments tests of Bell's inequalities with pairs of low energy correlated photons

    International Nuclear Information System (INIS)

    Aspect, A.

    1986-01-01

    This paper reviews the essence of Bell's reasoning, the purpose of which is to convince the reader that a very natural way of understanding the EPR correlations is to complete quantum mechanics in the way considered by Bell. It is noted that Bell's theorem states a conflict between local supplementary parameters theories and certain quantum mechanical predictions. It yields a quantitative criterion for this conflict, that allows one to design sensitive experiments. These experiments are presented in the paper. It is concluded that the predictions of quantum mechanics in EPR-type situations are vindicated by the experiments

  18. Status of the Correlation Process of the V-HAB Simulation with Ground Tests and ISS Telemetry Data

    Science.gov (United States)

    Ploetner, P.; Roth, C.; Zhukov, A.; Czupalla, M.; Anderson, M.; Ewert, M.

    2013-01-01

    The Virtual Habitat (V-HAB) is a dynamic Life Support System (LSS) simulation, created for investigation of future human spaceflight missions. It provides the capability to optimize LSS during early design phases. The focal point of the paper is the correlation and validation of V-HAB against ground test and flight data. In order to utilize V-HAB to design an Environmental Control and Life Support System (ECLSS) it is important to know the accuracy of simulations, strengths and weaknesses. Therefore, simulations of real systems are essential. The modeling of the International Space Station (ISS) ECLSS in terms of single technologies as well as an integrated system and correlation against ground and flight test data is described. The results of the simulations make it possible to prove the approach taken by V-HAB.

  19. Abnormalities on magnetic resonance imaging seen acutely following mild traumatic brain injury: correlation with neuropsychological tests and delayed recovery

    International Nuclear Information System (INIS)

    Hughes, David G.; Jackson, Alan; Mason, Damon L.; Berry, Elizabeth; Hollis, Sally; Yates, David W.

    2004-01-01

    Mild traumatic brain injury (MTBI) is a common reason for hospital attendance and is associated with significant delayed morbidity. We studied a series of 80 persons with MTBI. Magnetic resonance imaging (MRI) and neuropsychological testing were used in the acute phase and a questionnaire for post-concussion syndrome (PCS) and return to work status at 6 months. In 26 subjects abnormalities were seen on MRI, of which 5 were definitely traumatic. There was weak correlation with abnormal neuropsychological tests for attention in the acute period. There was no significant correlation with a questionnaire for PCS and return to work status. Although non-specific abnormalities are frequently seen, standard MRI techniques are not helpful in identifying patients with MTBI who are likely to have delayed recovery. (orig.)

  20. Correlations between psychopathology and self-reported quality of life among adolescents in youth correctional facilities in Lagos, Nigeria: A short report.

    Science.gov (United States)

    Atilola, Olayinka; Ola, Bolanle; Abiri, Gbonjubola; Adewuya, Abiodun O

    2018-02-01

    The relationship between psychopathology and quality of life (QoL) and well-being among young incarcerated offenders has hardly been explored. Our aim was to test the hypothesis that higher self-rated psychopathology would be associated with lower QoL among adolescents resident within youth correctional facilities in Lagos. Psychopathology was assessed using the Strength and Difficulty Questionnaire (SDQ), while QoL was measured by using the Paediatric Quality of Life. One hundred and sixty-five adolescents completed the study, mostly boys (n = 124; 75%) with a mean age of 14.3 ± 2.1 years. Nearly, a fifth (30, 18%) of respondents had abnormal total SDQ scores (≥17), suggestive of definite psychiatric disorder, while another 44 (27%) had highly probable psychopathology (total SDQ scores 15-16). There was strong negative correlation (r = -0.51, p psychopathology and QoL among these adolescents, it is plausible to suppose that treatment of mental health problems could have a positive impact on rehabilitation and reintegration. Given the rate of likely psychopathology, mental health screening within young offender institutions should be routine, and followed, as necessary with full assessment and resultant treatment. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  1. Comparison of Short and Long Versions of the Prudhoe Cognitive Function Test and the K-BIT in Participants with Intellectual Impairment

    Science.gov (United States)

    Tyrer, Stephen P.; Wigham, Ann; Cicchetti, Domenic; Margallo-Lana, Marisa; Moore, P. Brian; Reid, Barbara E.

    2010-01-01

    The Prudhoe Cognitive Function Test (PCFT) directly measures the cognitive abilities of people with intellectual impairment. This study examined the relationship between this instrument and the Kaufman Brief Intelligence Test (K-BIT) and two shorter versions of the same scale. High correlations between the verbal and performance sections of the…

  2. A Correlated Study of the Response of a Satellite to Acoustic Radiation Using Statistical Energy Analysis and Acoustic Test Data

    International Nuclear Information System (INIS)

    CAP, JEROME S.; TRACEY, BRIAN

    1999-01-01

    Aerospace payloads, such as satellites, are subjected to vibroacoustic excitation during launch. Sandia's MTI satellite has recently been certified to this environment using a combination of base input random vibration and reverberant acoustic noise. The initial choices for the acoustic and random vibration test specifications were obtained from the launch vehicle Interface Control Document (ICD). In order to tailor the random vibration levels for the laboratory certification testing, it was necessary to determine whether vibration energy was flowing across the launch vehicle interface from the satellite to the launch vehicle or the other direction. For frequencies below 120 Hz this issue was addressed using response limiting techniques based on results from the Coupled Loads Analysis (CLA). However, since the CLA Finite Element Analysis FEA model was only correlated for frequencies below 120 Hz, Statistical Energy Analysis (SEA) was considered to be a better choice for predicting the direction of the energy flow for frequencies above 120 Hz. The existing SEA model of the launch vehicle had been developed using the VibroAcoustic Payload Environment Prediction System (VAPEPS) computer code[1]. Therefore, the satellite would have to be modeled using VAPEPS as well. As is the case for any computational model, the confidence in its predictive capability increases if one can correlate a sample prediction against experimental data. Fortunately, Sandia had the ideal data set for correlating an SEA model of the MTI satellite--the measured response of a realistic assembly to a reverberant acoustic test that was performed during MTI's qualification test series. The first part of this paper will briefly describe the VAPEPS modeling effort and present the results of the correlation study for the VAPEPS model. The second part of this paper will present the results from a study that used a commercial SEA software package[2] to study the effects of in-plane modes and to evaluate

  3. Correlation between HRCT findings, pulmonary function tests and bronchoalveolar lavage cytology in interstitial lung disease associated with rheumatoid arthritis

    International Nuclear Information System (INIS)

    Biederer, J.; Muhle, C.; Heller, M.; Reuter, M.; Schnabel, A.; Gross, W.L.

    2004-01-01

    A prospective study correlating high-resolution computed tomography (HRCT), lung function tests (PFT) and bronchoalveolar lavage (BAL) cytology in patients with interstitial lung disease (ILD) associated with rheumatoid arthritis (RA). Fifty-three RA patients with suspected ILD (19 men, 34 women) underwent 71 HRCT (14 of 53 with sequential HRCT, mean follow-up 24.3 months). The HRCT evaluation by two observers on consensus included a semi-quantitative characterisation of lesion pattern and profusion on representative anatomical levels. Fifty-two HRCT were followed by PFT and BAL. Agreement or discordance of HRCT-, PFT- and BAL findings were analysed with Pearson's correlation, κ score and McNemar's test. Tobacco-fume exposure was estimated in pack years. Smoking/non-smoking groups were compared with Student's t test. In 49 of 53 patients, HRCT was suggestive of ILD associated with RA (66 of 71 HRCT). Reticular lesions were found in 40 of 53 patients, in 15 of 40 presenting as mixed pattern with ground-glass opacities (GGO). Pure reticular patterns predominated in patients with long duration of ILD (p>0.01). Pure GGO were not observed. Lesion profusion was highly variable and correlated moderately negative with diffusion capacity (mean 88.2% (SD±20.9%); r=-0.54; p 0.2), but not towards lymphocytosis (κ=0.10; p=0.23; McNemar test p>0.2). Differences in smoking history were not significant (p>0.1). The HRCT appears most appropriate for the detection and follow-up of ILD associated with RA. The PFT and BAL correlate only partially with lesion profusion or grading on HRCT, but they contribute valuable information about dynamic lung function and differential diagnoses (pneumonia, medication side effects). (orig.)

  4. Rankings of International Achievement Test Performance and Economic Strength: Correlation or Conjecture?

    Directory of Open Access Journals (Sweden)

    CHRISTOPHER H. TIENKEN

    2008-04-01

    Full Text Available Examining a popular political notion, this article presents results from a series of Spearman Rho calculations conducted to investigate relationships between countries’ rankings on international tests of mathematics and science and future economic competitiveness as measured by the 2006 World Economic Forum’s Growth Competitiveness Index (GCI. The study investigated the existence of relationships between international test rankings from three different time periods during the last 50 years of U.S. education policy development (i.e., 1957–1982, 1983–2000, and 2001–2006 and 2006 GCI ranks. It extends previous research on the topic by investigating how GCI rankings in the top 50 percent and bottom 50 percent relate to rankings on international tests for the countries that participated in each test. The study found that the relationship between ranks on international tests of mathematics and science and future economic strength is stronger among nations with lower-performing economies. Nations with strong economies, such as the United States, demonstrate a weaker, nonsignificant relationship.

  5. The intramuscular glucagon stimulation test does not provide good discrimination between normal and inadequate ACTH reserve when used in the investigation of short healthy children.

    Science.gov (United States)

    Tenenbaum, Ariel; Phillip, Moshe; de Vries, Liat

    2014-01-01

    Few studies have addressed the role of the glucagon stimulation test (GST) in evaluating the hypothalamic-pituitary-adrenal axis in children. We investigated the diagnostic value of the GST in evaluating the adrenocortical response in short healthy children. The GST was performed in 190 children investigated for short stature. A peak cortisol >500 nmol/l was considered a normal response. In the 45 (23.7%) with subnormal response, a 250-μg ACTH test was done. The rate of subnormal adrenal response to GST was higher among boys (33.9 vs. 8.9%, p 500 nmol/l in all the patients undergoing an ACTH stimulation test. Since adrenal response to GST is age- and gender-related and the false-positive rate is high, its routine performance in healthy children warrants reconsideration. © 2014 S. Karger AG, Basel.

  6. Prevalence and Correlates of Physical Fitness Testing in U.S. Schools--2000

    Science.gov (United States)

    Morrow, James R., Jr.; Fulton, Janet E.; Brener, Nancy D.; Kohl, Harold W., III

    2008-01-01

    Because of the perceived lack of youth physical fitness and/or concerns for increased obesity, physical education teachers are interested in youth fitness and physical activity levels. Statewide mandates are being developed that require school-based teachers to complete physical fitness testing. Data from the nationally representative School…

  7. Psychological Correlates of School Bullying Victimization: Academic Self-Concept, Learning Motivation and Test Anxiety

    Science.gov (United States)

    Caputo, Andrea

    2014-01-01

    The paper aims at detecting the association between students' bullying victimization at school and some psychological dimensions, referred to academic self-concept (for both Mathematics and Reading), learning motivation (intrinsic motivation, extrinsic motivation, commitment to study) and test anxiety. A questionnaire including these measures was…

  8. A Correlational Study: Code of Ethics in Testing and EFL Instructors' Professional Behavior

    Science.gov (United States)

    Ashraf, Hamid; Kafi, Zahra; Saeedan, Azaam

    2018-01-01

    The present study has aimed at delving the code of ethics in testing in English language institutions to see how far adhering to these ethical codes will result in EFL teachers' professional behavior. Therefore, 300 EFL instructors teaching at English language schools in Khorasan Razavi Province, Zabansara Language School, as well as Khorasan…

  9. Lumped Parameter Modeling for Rapid Vibration Response Prototyping and Test Correlation for Electronic Units

    Science.gov (United States)

    Van Dyke, Michael B.

    2013-01-01

    Present preliminary work using lumped parameter models to approximate dynamic response of electronic units to random vibration; Derive a general N-DOF model for application to electronic units; Illustrate parametric influence of model parameters; Implication of coupled dynamics for unit/board design; Demonstrate use of model to infer printed wiring board (PWB) dynamics from external chassis test measurement.

  10. Social and Behavioural Correlates of HIV Testing Among Australian Gay and Bisexual Men in Regular Relationships

    NARCIS (Netherlands)

    Lee, Evelyn; Murphy, Dean; Mao, Limin; de Wit, John; Prestage, Garrett; Zablotska, Iryna; Holt, Martin

    In this study we sought to identify the social and behavioural characteristics of Australian gay and bisexual men who had and had not tested for HIV during their current relationship. The results were based on 2012 and 2013 data collected from ongoing cross-sectional and community-based surveys held

  11. An alternative to the BDS test: integration across the correlation integral

    Czech Academy of Sciences Publication Activity Database

    Kočenda, Evžen

    2001-01-01

    Roč. 20, č. 3 (2001), s. 337-351 ISSN 0747-4938 Institutional research plan: CEZ:AV0Z7085904 Keywords : BDS test Subject RIV: BB - Applied Statistics, Operational Research http://search. ebscohost .com/login.aspx?direct=true&db=bth&AN=8533996&site=ehost-live

  12. Rankings of International Achievement Test Performance and Economic Strength: Correlation or Conjecture?

    Science.gov (United States)

    Tienken, Christopher H.

    2008-01-01

    Examining a popular political notion, this article presents results from a series of Spearman Rho calculations conducted to investigate relationships between countries' rankings on international tests of mathematics and science and future economic competitiveness as measured by the 2006 World Economic Forum's Growth Competitiveness Index (GCI).…

  13. Testing the Planet-Metallicity Correlation in M-dwarfs with Gemini GNIRS Spectra

    Science.gov (United States)

    Hobson, M. J.; Jofré, E.; García, L.; Petrucci, R.; Gómez, M.

    2018-04-01

    While the planet-metallicity correlation for FGK main-sequence stars hosting giant planets is well established, it is less clear for M-dwarf stars. We determine stellar parameters and metallicities for 16 M-dwarf stars, 11 of which host planets, with near-infrared spectra from the Gemini Near-Infrared Spectrograph (GNIRS). We find that M-dwarfs with planets are preferentially metal-rich compared to those without planets. This result is supported by the analysis of a larger catalogue of 18 M stars with planets and 213 M stars without known planets T15, and demonstrates the utility of GNIRS spectra to obtain reliable stellar parameters of M stars. We also find that M dwarfs with giant planets are preferentially more metallic than those with low-mass planets, in agreement with previous results for solar-type stars. These results favor the core accretion model of planetary formation.

  14. How to Say No: Single- and Dual-Process Theories of Short-Term Recognition Tested on Negative Probes

    Science.gov (United States)

    Oberauer, Klaus

    2008-01-01

    Three experiments with short-term recognition tasks are reported. In Experiments 1 and 2, participants decided whether a probe matched a list item specified by its spatial location. Items presented at study in a different location (intrusion probes) had to be rejected. Serial position curves of positive, new, and intrusion probes over the probed…

  15. Neural correlates of four broad temperament dimensions: testing predictions for a novel construct of personality.

    Directory of Open Access Journals (Sweden)

    Lucy L Brown

    Full Text Available Four suites of behavioral traits have been associated with four broad neural systems: the 1 dopamine and related norepinephrine system; 2 serotonin; 3 testosterone; 4 and estrogen and oxytocin system. A 56-item questionnaire, the Fisher Temperament Inventory (FTI, was developed to define four temperament dimensions associated with these behavioral traits and neural systems. The questionnaire has been used to suggest romantic partner compatibility. The dimensions were named: Curious/Energetic; Cautious/Social Norm Compliant; Analytical/Tough-minded; and Prosocial/Empathetic. For the present study, the FTI was administered to participants in two functional magnetic resonance imaging studies that elicited feelings of love and attachment, near-universal human experiences. Scores for the Curious/Energetic dimension co-varied with activation in a region of the substantia nigra, consistent with the prediction that this dimension reflects activity in the dopamine system. Scores for the Cautious/Social Norm Compliant dimension correlated with activation in the ventrolateral prefrontal cortex in regions associated with social norm compliance, a trait linked with the serotonin system. Scores on the Analytical/Tough-minded scale co-varied with activity in regions of the occipital and parietal cortices associated with visual acuity and mathematical thinking, traits linked with testosterone. Also, testosterone contributes to brain architecture in these areas. Scores on the Prosocial/Empathetic scale correlated with activity in regions of the inferior frontal gyrus, anterior insula and fusiform gyrus. These are regions associated with mirror neurons or empathy, a trait linked with the estrogen/oxytocin system, and where estrogen contributes to brain architecture. These findings, replicated across two studies, suggest that the FTI measures influences of four broad neural systems, and that these temperament dimensions and neural systems could constitute

  16. Neural correlates of four broad temperament dimensions: testing predictions for a novel construct of personality.

    Science.gov (United States)

    Brown, Lucy L; Acevedo, Bianca; Fisher, Helen E

    2013-01-01

    Four suites of behavioral traits have been associated with four broad neural systems: the 1) dopamine and related norepinephrine system; 2) serotonin; 3) testosterone; 4) and estrogen and oxytocin system. A 56-item questionnaire, the Fisher Temperament Inventory (FTI), was developed to define four temperament dimensions associated with these behavioral traits and neural systems. The questionnaire has been used to suggest romantic partner compatibility. The dimensions were named: Curious/Energetic; Cautious/Social Norm Compliant; Analytical/Tough-minded; and Prosocial/Empathetic. For the present study, the FTI was administered to participants in two functional magnetic resonance imaging studies that elicited feelings of love and attachment, near-universal human experiences. Scores for the Curious/Energetic dimension co-varied with activation in a region of the substantia nigra, consistent with the prediction that this dimension reflects activity in the dopamine system. Scores for the Cautious/Social Norm Compliant dimension correlated with activation in the ventrolateral prefrontal cortex in regions associated with social norm compliance, a trait linked with the serotonin system. Scores on the Analytical/Tough-minded scale co-varied with activity in regions of the occipital and parietal cortices associated with visual acuity and mathematical thinking, traits linked with testosterone. Also, testosterone contributes to brain architecture in these areas. Scores on the Prosocial/Empathetic scale correlated with activity in regions of the inferior frontal gyrus, anterior insula and fusiform gyrus. These are regions associated with mirror neurons or empathy, a trait linked with the estrogen/oxytocin system, and where estrogen contributes to brain architecture. These findings, replicated across two studies, suggest that the FTI measures influences of four broad neural systems, and that these temperament dimensions and neural systems could constitute foundational mechanisms

  17. Internal short circuit and accelerated rate calorimetry tests of lithium-ion cells: Considerations for methane-air intrinsic safety and explosion proof/flameproof protection methods.

    Science.gov (United States)

    Dubaniewicz, Thomas H; DuCarme, Joseph P

    2016-09-01

    Researchers with the National Institute for Occupational Safety and Health (NIOSH) studied the potential for lithium-ion cell thermal runaway from an internal short circuit in equipment for use in underground coal mines. In this third phase of the study, researchers compared plastic wedge crush-induced internal short circuit tests of selected lithium-ion cells within methane (CH 4 )-air mixtures with accelerated rate calorimetry tests of similar cells. Plastic wedge crush test results with metal oxide lithium-ion cells extracted from intrinsically safe evaluated equipment were mixed, with one cell model igniting the chamber atmosphere while another cell model did not. The two cells models exhibited different internal short circuit behaviors. A lithium iron phosphate (LiFePO 4 ) cell model was tolerant to crush-induced internal short circuits within CH 4 -air, tested under manufacturer recommended charging conditions. Accelerating rate calorimetry tests with similar cells within a nitrogen purged 353-mL chamber produced ignitions that exceeded explosion proof and flameproof enclosure minimum internal pressure design criteria. Ignition pressures within a 20-L chamber with 6.5% CH 4 -air were relatively low, with much larger head space volume and less adiabatic test conditions. The literature indicates that sizeable lithium thionyl chloride (LiSOCl 2 ) primary (non rechargeable) cell ignitions can be especially violent and toxic. Because ignition of an explosive atmosphere is expected within explosion proof or flameproof enclosures, there is a need to consider the potential for an internal explosive atmosphere ignition in combination with a lithium or lithium-ion battery thermal runaway process, and the resulting effects on the enclosure.

  18. Buckling Test Results and Preliminary Test and Analysis Correlation from the 8-Foot-Diameter Orthogrid-Stiffened Cylinder Test Article TA02

    Science.gov (United States)

    Hilburger, Mark W.; Waters, W. Allen, Jr.; Haynie, Waddy T.; Thornburgh, Robert P

    2017-01-01

    Results from the testing of cylinder test article SBKF-P2-CYL-TA02 (referred to herein as TA02) are presented. TA02 is an 8-foot-diameter (96-inches), 78.0-inch-long, aluminum-lithium (Al-Li), orthogrid-stiffened cylindrical shell similar to those used in current state-of-the-art launch-vehicle structures and was designed to exhibit global buckling when subjected to combined compression and bending loads. The testing was conducted at the Marshall Space Flight Center (MSFC), February 3-6, 2009, in support of the Shell Buckling Knockdown Factor Project (SBKF). The test was used to verify the performance of a newly constructed buckling test facility at MSFC and to verify the test article design and analysis approach used by the SBKF researchers.

  19. Correlation between induced embryo toxicity and absorption dose of enriched uranium in testes

    International Nuclear Information System (INIS)

    Zhu Shoupeng; Lun Mingyue

    1996-01-01

    Doses of enriched uranium in testes inducing dominant lethality and skeletal abnormalities in offsprings are estimated. When intra-testicular injection dose is 0.4∼60 μg enriched uranium; from intake to insemination, testes could receive 9.14 x 10 -5 ∼1.38 x 10 -2 Gy radiation dose. Experimental results show that with the increase in the absorption dose, the number of living fetuses in a litter decreases, dominant lethality and skeletal abnormalities rise. It should be noted that relationship between the injected dose (I in μg) and the incidence of dominant skeletal abnormalities (S in %) in the offsprings can be represented by equation: S = 28.84 + 0.84I

  20. Correlation between induced embryo toxicity and absorption dose of enriched uranium in testes

    Energy Technology Data Exchange (ETDEWEB)

    Shoupeng, Zhu; Mingyue, Lun [Suzhou Medical Coll., JS (China)

    1996-08-01

    Doses of enriched uranium in testes inducing dominant lethality and skeletal abnormalities in offsprings are estimated. When intra-testicular injection dose is 0.4{approx}60 {mu}g enriched uranium; from intake to insemination, testes could receive 9.14 x 10{sup -5}{approx}1.38 x 10{sup -2} Gy radiation dose. Experimental results show that with the increase in the absorption dose, the number of living fetuses in a litter decreases, dominant lethality and skeletal abnormalities rise. It should be noted that relationship between the injected dose (I in {mu}g) and the incidence of dominant skeletal abnormalities (S in %) in the offsprings can be represented by equation: S = 28.84 + 0.84I.