WorldWideScience

Sample records for short record length

  1. Short Rayleigh Length Free Electron Lasers

    CERN Document Server

    Crooker, P P; Armstead, R L; Blau, J

    2004-01-01

    Conventional free electron laser (FEL) oscillators minimize the optical mode volume around the electron beam in the undulator by making the resonator Rayleigh length about one third of the undulator length. This maximizes gain and beam-mode coupling. In compact configurations of high-power infrared FELs or moderate power UV FELs, the resulting optical intensity can damage the resonator mirrors. To increase the spot size and thereby reduce the optical intensity at the mirrors below the damage threshold, a shorter Rayleigh length can be used, but the FEL interaction is significantly altered. A new FEL interaction is described and analyzed with a Rayleigh length that is only one tenth the undulator length, or less. The effect of mirror vibration and positioning are more critical in the short Rayleigh length design, but we find that they are still within normal design tolerances.

  2. Validity of (Ultra-Short Recordings for Heart Rate Variability Measurements.

    Directory of Open Access Journals (Sweden)

    M Loretto Munoz

    Full Text Available In order to investigate the applicability of routine 10s electrocardiogram (ECG recordings for time-domain heart rate variability (HRV calculation we explored to what extent these (ultra-short recordings capture the "actual" HRV.The standard deviation of normal-to-normal intervals (SDNN and the root mean square of successive differences (RMSSD were measured in 3,387 adults. SDNN and RMSSD were assessed from (ultrashort recordings of 10s(3x, 30s, and 120s and compared to 240s-300s (gold standard measurements. Pearson's correlation coefficients (r, Bland-Altman 95% limits of agreement and Cohen's d statistics were used as agreement analysis techniques.Agreement between the separate 10s recordings and the 240s-300s recording was already substantial (r = 0.758-0.764/Bias = 0.398-0.416/d = 0.855-0.894 for SDNN; r = 0.853-0.862/Bias = 0.079-0.096/d = 0.150-0.171 for RMSSD, and improved further when three 10s periods were averaged (r = 0.863/Bias = 0.406/d = 0.874 for SDNN; r = 0.941/Bias = 0.088/d = 0.167 for RMSSD. Agreement increased with recording length and reached near perfect agreement at 120s (r = 0.956/Bias = 0.064/d = 0.137 for SDNN; r = 0.986/Bias = 0.014/d = 0.027 for RMSSD. For all recording lengths and agreement measures, RMSSD outperformed SDNN.Our results confirm that it is unnecessary to use recordings longer than 120s to obtain accurate measures of RMSSD and SDNN in the time domain. Even a single 10s (standard ECG recording yields a valid RMSSD measurement, although an average over multiple 10s ECGs is preferable. For SDNN we would recommend either 30s or multiple 10s ECGs. Future research projects using time-domain HRV parameters, e.g. genetic epidemiological studies, could calculate HRV from (ultra-short ECGs enabling such projects to be performed at a large scale.

  3. Climate reconstructions derived from global glacier length records

    NARCIS (Netherlands)

    Klok, E.J.; Oerlemans, J.

    2004-01-01

    As glacier length fluctuations provide useful information about past climate, we derived historic fluctuations in the equilibrium-line altitude (ELA) on the basis of 19 glacier length records from different parts of the world. We used a model that takes into account the geometry of the glacier,

  4. The Sensetivity of Flood Frequency Analysis on Record Length in Continuous United States

    Science.gov (United States)

    Hu, L.; Nikolopoulos, E. I.; Anagnostou, E. N.

    2017-12-01

    In flood frequency analysis (FFA), sufficiently long data series are important to get more reliable results. Compared to return periods of interest, at-site FFA usually needs large data sets. Generally, the precision of at site estimators and time-sampling errors are associated with the length of a gauged record. In this work, we quantify the difference with various record lengths. we use generalized extreme value (GEV) and Log Pearson type III (LP3), two traditional methods on annual maximum stream flows to undertake FFA, and propose quantitative ways, relative difference in median and interquartile range (IQR) to compare the flood frequency performances on different record length from selected 350 USGS gauges, which have more than 70 years record length in Continuous United States. Also, we group those gauges into different regions separately based on hydrological unit map and discuss the geometry impacts. The results indicate that long record length can avoid imposing an upper limit on the degree of sophistication. Working with relatively longer record length may lead accurate results than working with shorter record length. Furthermore, the influence of hydrologic unites for the watershed boundary dataset on those gauges also be presented. The California region is the most sensitive to record length, while gauges in the east perform steady.

  5. Short initial length quench on CICC of ITER TF coils

    Energy Technology Data Exchange (ETDEWEB)

    Nicollet, S.; Ciazynski, D.; Duchateau, J.-L.; Lacroix, B. [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France); Bessette, D.; Rodriguez-Mateos, F. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Coatanea-Gouachet, M. [ELC Engineering, 350 chemin du Verladet, F-13290 Les Milles (France); Gauthier, F. [Soditech Ingenierie, 4 bis allée des Gabians, ZI La Frayère, 06150 Cannes (France)

    2014-01-29

    Previous quench studies performed for the International Thermonuclear Experimental Reactor (ITER) Toroidal Field (TF) Coils have led to identify two extreme families of quench: first 'severe' quenches over long initial lengths in high magnetic field, and second smooth quenches over short initial lengths in low field region. Detailed analyses and results on smooth quench propagation and detectability on one TF Cable In Conduit Conductor (CICC) with a lower propagation velocity are presented here. The influence of the initial quench energy is shown and results of computations with either a Fast Discharge (FD) of the magnet or without (failure of the voltage quench detection system) are reported. The influence of the central spiral of the conductor on the propagation velocity is also detailed. In the cases of a regularly triggered FD, the hot spot temperature criterion of 150 K (with helium and jacket) is fulfilled for an initial quench length of 1 m, whereas this criterion is exceed (Tmax ≈ 200 K) for an extremely short length of 5 cm. These analyses were carried out using both the Supermagnet(trade mark, serif) and Venecia codes and the comparisons of the results are also discussed.

  6. Short initial length quench on CICC of ITER TF coils

    International Nuclear Information System (INIS)

    Nicollet, S.; Ciazynski, D.; Duchateau, J.-L.; Lacroix, B.; Bessette, D.; Rodriguez-Mateos, F.; Coatanea-Gouachet, M.; Gauthier, F.

    2014-01-01

    Previous quench studies performed for the International Thermonuclear Experimental Reactor (ITER) Toroidal Field (TF) Coils have led to identify two extreme families of quench: first 'severe' quenches over long initial lengths in high magnetic field, and second smooth quenches over short initial lengths in low field region. Detailed analyses and results on smooth quench propagation and detectability on one TF Cable In Conduit Conductor (CICC) with a lower propagation velocity are presented here. The influence of the initial quench energy is shown and results of computations with either a Fast Discharge (FD) of the magnet or without (failure of the voltage quench detection system) are reported. The influence of the central spiral of the conductor on the propagation velocity is also detailed. In the cases of a regularly triggered FD, the hot spot temperature criterion of 150 K (with helium and jacket) is fulfilled for an initial quench length of 1 m, whereas this criterion is exceed (Tmax ≈ 200 K) for an extremely short length of 5 cm. These analyses were carried out using both the Supermagnet(trade mark, serif) and Venecia codes and the comparisons of the results are also discussed

  7. Influence of recording length on reporting status

    DEFF Research Database (Denmark)

    Biltoft-Jensen, Anja Pia; Matthiessen, Jeppe; Fagt, Sisse

    2009-01-01

    : To investigate the impact of recording length on reporting status, expressed as the ratio between energy intake and calculated basal metabolic rate (EI/BMR), the percentage of consumers of selected food items and the number reported food items per meal and eating occasions per day. Methods: Data from two...... in a validation study and the Danish National Survey of Dietary Habits and Physical Activity 2000-2002, respectively. Both studies had a cross-sectional design. Volunteers and participants completed a pre-coded food diary every day for 7 consecutive days. BMR was predicted from equations. Results......: In the validation study, EI/BMR was significantly lower on 1st, 2nd and 3rd consecutive recording days compared to 4-7 recording days (P food items...

  8. Data bank for short-length red oak lumber

    Science.gov (United States)

    Janice K. Wiedenbeck; Charles J. Gatchell; Elizabeth S. Walker

    1994-01-01

    This data bank for short-length lumber (less than 8 feet long) contains information on board outlines and defect size and quality for 426 414-inch-thick red oak boards. The Selects, 1 Common, 2A Common, and 3A Common grades are represented in the data bank. The data bank provides the kind of detailed lumber description that is required as input by computer programs...

  9. Short telomere length, lung function and chronic obstructive pulmonary disease in 46,396 individuals

    DEFF Research Database (Denmark)

    Rode, Line; Bojesen, Stig Egil; Weischer, Maren

    2013-01-01

    A previous case-control study of 100 individuals found that short telomere length was associated with a 28-fold increased risk of chronic obstructive pulmonary disease (COPD).......A previous case-control study of 100 individuals found that short telomere length was associated with a 28-fold increased risk of chronic obstructive pulmonary disease (COPD)....

  10. Non-universality of critical exponents in the paraconductivity of short-coherence-length superconductors

    International Nuclear Information System (INIS)

    Gauzzi, A.

    1993-01-01

    The Aslamazov-Larkin paraconductivity term is calculated in the case of sufficiently small superconducting coherence length. It is found that the critical exponent of paraconductivity depends on the short-wavelength cut-off of the fluctuation spectrum in the whole Ginzburg-Landau mean-field region. Hence, it is predicted that the Aslamazov-Larkin universal relation between the critical exponent of paraconductivity and the dimensionality of the superconducting state is no longer valid in short-coherence-length superconductors. This prediction is confirmed by paraconductivity measurements on cuprate superconductors. (orig.)

  11. Strong and long: effects of word length on phonological binding in verbal short-term memory.

    Science.gov (United States)

    Jefferies, Elizabeth; Frankish, Clive; Noble, Katie

    2011-02-01

    This study examined the effects of item length on the contribution of linguistic knowledge to immediate serial recall (ISR). Long words are typically recalled more poorly than short words, reflecting the greater demands that they place on phonological encoding, rehearsal, and production. However, reverse word length effects--that is, better recall of long than short words--can also occur in situations in which phonological maintenance is difficult, suggesting that long words derive greater support from long-term lexical knowledge. In this study, long and short words and nonwords (containing one vs. three syllables) were presented for immediate serial recall in (a) pure lists and (b) unpredictable mixed lists of words and nonwords. The mixed-list paradigm is known to disrupt the phonological stability of words, encouraging their phonemes to recombine with the elements of other list items. In this situation, standard length effects were seen for nonwords, while length effects for words were absent or reversed. A detailed error analysis revealed that long words were more robust to the mixed-list manipulation than short words: Their phonemes were less likely to be omitted and to recombine with phonemes from other list items. These findings support an interactive view of short-term memory, in which long words derive greater benefits from lexical knowledge than short words-especially when their phonological integrity is challenged by the inclusion of nonwords in mixed lists.

  12. Word length, set size, and lexical factors: Re-examining what causes the word length effect.

    Science.gov (United States)

    Guitard, Dominic; Gabel, Andrew J; Saint-Aubin, Jean; Surprenant, Aimée M; Neath, Ian

    2018-04-19

    The word length effect, better recall of lists of short (fewer syllables) than long (more syllables) words has been termed a benchmark effect of working memory. Despite this, experiments on the word length effect can yield quite different results depending on set size and stimulus properties. Seven experiments are reported that address these 2 issues. Experiment 1 replicated the finding of a preserved word length effect under concurrent articulation for large stimulus sets, which contrasts with the abolition of the word length effect by concurrent articulation for small stimulus sets. Experiment 2, however, demonstrated that when the short and long words are equated on more dimensions, concurrent articulation abolishes the word length effect for large stimulus sets. Experiment 3 shows a standard word length effect when output time is equated, but Experiments 4-6 show no word length effect when short and long words are equated on increasingly more dimensions that previous demonstrations have overlooked. Finally, Experiment 7 compared recall of a small and large neighborhood words that were equated on all the dimensions used in Experiment 6 (except for those directly related to neighborhood size) and a neighborhood size effect was still observed. We conclude that lexical factors, rather than word length per se, are better predictors of when the word length effect will occur. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  13. The effect of word length in short-term memory: Is rehearsal necessary?

    Science.gov (United States)

    Campoy, Guillermo

    2008-05-01

    Three experiments investigated the effect of word length on a serial recognition task when rehearsal was prevented by a high presentation rate with no delay between study and test lists. Results showed that lists of short four-phoneme words were better recognized than lists of long six-phoneme words. Moreover, this effect was equivalent to that observed in conditions in which there was a delay between lists, thereby making rehearsal possible in the interval. These findings imply that rehearsal does not play a central role in the origin of the word length effect. An alternative explanation based on differences in the degree of retroactive interference generated by long and short words is proposed.

  14. Modelling of the glass fiber length and the glass fiber length distribution in the compounding of short glass fiber-reinforced thermoplastics

    Science.gov (United States)

    Kloke, P.; Herken, T.; Schöppner, V.; Rudloff, J.; Kretschmer, K.; Heidemeyer, P.; Bastian, M.; Walther, Dridger, A.

    2014-05-01

    The use of short glass fiber-reinforced thermoplastics for the production of highly stressed parts in the plastics processing industry has experienced an enormous boom in the last few years. The reasons for this are primarily the improvements to the stiffness and strength properties brought about by fiber reinforcement. These positive characteristics of glass fiber-reinforced polymers are governed predominantly by the mean glass fiber length and the glass fiber length distribution. It is not enough to describe the properties of a plastics component solely as a function of the mean glass fiber length [1]. For this reason, a mathematical-physical model has been developed for describing the glass fiber length distribution in compounding. With this model, it is possible on the one hand to optimize processes for the production of short glass fiber-reinforced thermoplastics, and, on the other, to obtain information on the final distribution, on the basis of which much more detailed statements can be made about the subsequent properties of the molded part. Based on experimental tests, it was shown that this model is able to accurately describe the change in glass fiber length distribution in compounding.

  15. Word-length effect in verbal short-term memory in individuals with Down's syndrome.

    Science.gov (United States)

    Kanno, K; Ikeda, Y

    2002-11-01

    Many studies have indicated that individuals with Down's syndrome (DS) show a specific deficit in short-term memory for verbal information. The aim of the present study was to investigate the influence of the length of words on verbal short-term memory in individuals with DS. Twenty-eight children with DS and 10 control participants matched for memory span were tested on verbal serial recall and speech rate, which are thought to involve rehearsal and output speed. Although a significant word-length effect was observed in both groups for the recall of a larger number of items with a shorter spoken duration than for those with a longer spoken duration, the number of correct recalls in the group with DS was reduced compared to the control subjects. The results demonstrating poor short-term memory in children with DS were irrelevant to speech rate. In addition, the proportion of repetition-gained errors in serial recall was higher in children with DS than in control subjects. The present findings suggest that poor access to long-term lexical knowledge, rather than overt articulation speed, constrains verbal short-term memory functions in individuals with DS.

  16. Flexibility of short DNA helices with finite-length effect: From base pairs to tens of base pairs

    International Nuclear Information System (INIS)

    Wu, Yuan-Yan; Bao, Lei; Zhang, Xi; Tan, Zhi-Jie

    2015-01-01

    Flexibility of short DNA helices is important for the biological functions such as nucleosome formation and DNA-protein recognition. Recent experiments suggest that short DNAs of tens of base pairs (bps) may have apparently higher flexibility than those of kilo bps, while there is still the debate on such high flexibility. In the present work, we have studied the flexibility of short DNAs with finite-length of 5–50 bps by the all-atomistic molecular dynamics simulations and Monte Carlo simulations with the worm-like chain model. Our microscopic analyses reveal that short DNAs have apparently high flexibility which is attributed to the significantly strong bending and stretching flexibilities of ∼6 bps at each helix end. Correspondingly, the apparent persistence length l p of short DNAs increases gradually from ∼29 nm to ∼45 nm as DNA length increases from 10 to 50 bps, in accordance with the available experimental data. Our further analyses show that the short DNAs with excluding ∼6 bps at each helix end have the similar flexibility with those of kilo bps and can be described by the worm-like chain model with l p ∼ 50 nm

  17. Recording length criteria as applied in ultrasonic testing

    International Nuclear Information System (INIS)

    Fischer, E.; Kroening, M.; Schober, H.; Fischdick, H.

    1983-01-01

    An appreciable method used to assess the quality and integrity of safety-related components in light water reactors is the ultrasonic examination, in which case great importance is attributed to the criteria pertaining to recording length and permissible defect size. The development of the recording length criteria as applied when employing this method of examination is portrayed, the latter being based on the criteria which have proven themselves throughout long years of practice in the examination of conventional components. When taking these criteria into account the application of conventional ultrasonic techniques often leads to problems in the case of thick-walled components the reason being that indications are overrated. Taking the design of reactor components as the basic point of consideration, modified criteria are derived particularly when the size of discontinuities calculated by fracture mechanics analyses is taken into account. The introduction of new ultrasonic examination techniques such as, for example, focussed probes revealed that a considerably more realistic assessment is possible and consequently results in a reduction of unnecessary repairs. A comparison of the size of indications determined using conventional and analytical technqiues renders possible the anchoring of an intermediate stage in the evaluation of indications which is encompassed in the consideration of the bundle divergence. Thus a new concept is realized for the evaluation of ultrasonic indications detected in reactor components, which in the meantime has found its way into the associated regulatory guides. (orig.)

  18. SHORT COMMUNICATIONS, NOTES AND REPORTS Record of ...

    African Journals Online (AJOL)

    Campbell Murn

    50. SHORT COMMUNICATIONS, NOTES AND. REPORTS. Record of Cinereous Vulture Aegypius monachus from Mukundara Hills Tiger Reserve, Rajasthan,. India. Sailaja Nayak1*, Sunny Shah2 and Jimmy Borah2 .... Prey status and abundance in Mukundara Hills Tiger. Reserve. Technical Report, WWF-India. Rao, J.P. ...

  19. A New Maximum Length Record of the Bluefish (Pomatomus saltatrix Linnaeus, 1766) for Turkey Seas

    OpenAIRE

    Cengiz, Özgür

    2014-01-01

    One specimen of the bluefish (Pomatomus saltatrix Linnaeus, 1766) with 76.5 cm in total length and 4800.0 g in total weight was photographed in the Çanakkale Fish Market. The given length is second maximum length record of the bluefish for Turkish waters

  20. Shot Noise Suppression in a Quantum Point Contact with Short Channel Length

    International Nuclear Information System (INIS)

    Jeong, Heejun

    2015-01-01

    An experimental study on the current shot noise of a quantum point contact with short channel length is reported. The experimentally measured maximum energy level spacing between the ground and the first excited state of the device reached up to 7.5 meV, probably due to the hard wall confinement by using shallow electron gas and sharp point contact geometry. The two-dimensional non-equilibrium shot noise contour map shows noise suppression characteristics in a wide range of bias voltage. Fano factor analysis indicates spin-polarized transport through a short quantum point contact. (paper)

  1. Unsupervised Idealization of Ion Channel Recordings by Minimum Description Length

    DEFF Research Database (Denmark)

    Gnanasambandam, Radhakrishnan; Nielsen, Morten S; Nicolai, Christopher

    2017-01-01

    and characterize an idealization algorithm based on Rissanen's Minimum Description Length (MDL) Principle. This method uses minimal assumptions and idealizes ion channel recordings without requiring a detailed user input or a priori assumptions about channel conductance and kinetics. Furthermore, we demonstrate...... that correlation analysis of conductance steps can resolve properties of single ion channels in recordings contaminated by signals from multiple channels. We first validated our methods on simulated data defined with a range of different signal-to-noise levels, and then showed that our algorithm can recover...... channel currents and their substates from recordings with multiple channels, even under conditions of high noise. We then tested the MDL algorithm on real experimental data from human PIEZO1 channels and found that our method revealed the presence of substates with alternate conductances....

  2. A Short Introduction to Model Selection, Kolmogorov Complexity and Minimum Description Length (MDL)

    NARCIS (Netherlands)

    Nannen, Volker

    2010-01-01

    The concept of overtting in model selection is explained and demon- strated. After providing some background information on information theory and Kolmogorov complexity, we provide a short explanation of Minimum Description Length and error minimization. We conclude with a discussion of the typical

  3. Validity of (Ultra-)Short Recordings for Heart Rate Variability Measurements

    NARCIS (Netherlands)

    Muñoz Venegas, Loretto; van Roon, Arie; Riese, Harriette; Thio, Chris; Oostenbroek, Emma; Westrik, Iris; de Geus, Eco J. C.; Gansevoort, Ron; Lefrandt, Joop; Nolte, Ilja M.; Snieder, Harold

    2015-01-01

    Objectives In order to investigate the applicability of routine 10s electrocardiogram (ECG) recordings for time-domain heart rate variability (HRV) calculation we explored to what extent these (ultra-)short recordings capture the "actual" HRV. Methods The standard deviation of normal-to-normal

  4. Estimating response times of Vadret da Morteratsch, Vadret da Palue, Briksdalsbreen and Nigardsbreen from their length records

    NARCIS (Netherlands)

    Oerlemans, J.

    2007-01-01

    Length records of two pairs of glaciers are used to reconstruct the equilibrium-line altitude (ELA) and to estimate glacier response times. The method is based on the assumption that neighbouring glaciers should be subject to the same climatic forcing, and that differences in the length records are

  5. Construction of Short-length High-rates Ldpc Codes Using Difference Families

    OpenAIRE

    Deny Hamdani; Ery Safrianti

    2007-01-01

    Low-density parity-check (LDPC) code is linear-block error-correcting code defined by sparse parity-check matrix. It isdecoded using the massage-passing algorithm, and in many cases, capable of outperforming turbo code. This paperpresents a class of low-density parity-check (LDPC) codes showing good performance with low encoding complexity.The code is constructed using difference families from combinatorial design. The resulting code, which is designed tohave short code length and high code r...

  6. Glycogen with short average chain length enhances bacterial durability

    Science.gov (United States)

    Wang, Liang; Wise, Michael J.

    2011-09-01

    Glycogen is conventionally viewed as an energy reserve that can be rapidly mobilized for ATP production in higher organisms. However, several studies have noted that glycogen with short average chain length in some bacteria is degraded very slowly. In addition, slow utilization of glycogen is correlated with bacterial viability, that is, the slower the glycogen breakdown rate, the longer the bacterial survival time in the external environment under starvation conditions. We call that a durable energy storage mechanism (DESM). In this review, evidence from microbiology, biochemistry, and molecular biology will be assembled to support the hypothesis of glycogen as a durable energy storage compound. One method for testing the DESM hypothesis is proposed.

  7. Recall of short word lists presented visually at fast rates: effects of phonological similarity and word length.

    Science.gov (United States)

    Coltheart, V; Langdon, R

    1998-03-01

    Phonological similarity of visually presented list items impairs short-term serial recall. Lists of long words are also recalled less accurately than are lists of short words. These results have been attributed to phonological recoding and rehearsal. If subjects articulate irrelevant words during list presentation, both phonological similarity and word length effects are abolished. Experiments 1 and 2 examined effects of phonological similarity and recall instructions on recall of lists shown at fast rates (from one item per 0.114-0.50 sec), which might not permit phonological encoding and rehearsal. In Experiment 3, recall instructions and word length were manipulated using fast presentation rates. Both phonological similarity and word length effects were observed, and they were not dependent on recall instructions. Experiments 4 and 5 investigated the effects of irrelevant concurrent articulation on lists shown at fast rates. Both phonological similarity and word length effects were removed by concurrent articulation, as they were with slow presentation rates.

  8. Extracting the respiration cycle lengths from ECG signal recorded with bed sheet electrodes

    International Nuclear Information System (INIS)

    Vehkaoja, A; Peltokangas, M; Lekkala, J

    2013-01-01

    A method for recognizing the respiration cycle lengths from the electrocardiographic (ECG) signal recorded with textile electrodes that are attached to a bed sheet is proposed. The method uses two features extracted from the ECG that are affected by the respiration: respiratory sinus arrhythmia and the amplitude of the R-peaks. The proposed method was tested in one hour long recordings with ten healthy young adults. A relative mean absolute error of 5.6 % was achieved when the algorithm was able to provide a result for approximately 40 % of the time. 90 % of the values were within 0.5 s and 97 % within 1 s from the reference respiration value. In addition to the instantaneous respiration cycle lengths, also the mean values during 1 and 5 minutes epochs are calculated. The effect of the ECG signal source is evaluated by calculating the result also from the simultaneously recorded reference ECG signal. The acquired respiration information can be used in the estimation of sleep quality and the detection of sleep disorders

  9. Short-wavelength magnetic recording new methods and analyses

    CERN Document Server

    Ruigrok, JJM

    2013-01-01

    Short-wavelength magnetic recording presents a series of practical solutions to a wide range of problems in the field of magnetic recording. It features many new and original results, all derived from fundamental principles as a result of up-to-date research.A special section is devoted to the playback process, including the calculations of head efficiency and head impedance, derived from new theorems.Features include:A simple and fast method for measuring efficiency; a simple method for the accurate separation of the read and write behaviour of magnetic heads; a new concept - the bandpass hea

  10. Stability of a short Rayleigh length laser resonator

    Directory of Open Access Journals (Sweden)

    P. P. Crooker

    2005-04-01

    Full Text Available Motivated by the prospect of constructing a short Rayleigh length free-electron laser in a high-vibration environment, we demonstrate the use of a collection of rays to study the effect of mirror vibration and distortion on the behavior of the fundamental optical mode of a cold-cavity resonator. We find that the ray collection accurately describes both on-axis and off-axis optical beams. We show that a tilt or transverse shift of a mirror causes the optical mode to rock about the original resonator axis, while a longitudinal mirror shift or a change in the mirror’s radius of curvature causes the beam diameter at a mirror to successively dilate and contract on the mirror. Results are in excellent agreement with analytic calculations and wave front propagation simulations as long as the mirrors remain large with respect to the beam diameter.

  11. QTL-mapping in mink (Neovison vison) shows evidence for QTL for guard hair thickness, guard hair length and skin length

    DEFF Research Database (Denmark)

    Thirstrup, Janne Pia; Labouriau, Rodrigo; Guldbrandtsen, Bernt

    2011-01-01

    Fur quality in mink (Neovison vison) is a composite trait, consisting of e.g. guard hair length, guard hair thickness and density of wool. A genome wide QTL search was performed to detect QTL for fur quality traits in mink. Here we present the results of QTL analyses for guard hair length, guard...... hair thickness and density of wool. Data from an F2-cross was analysed across fourteen chromosomes using 100 microsatellites as markers with a spacing of approximately 20 cM. The two lines used for the F2-cross were Nordic wild mink and American short nap mink. In total 1,083 animals (21 wild type, 25...... short nap, 103 F1 and 934 F2) were marker typed and recorded for the three presented fur quality traits. For the QTL-analyses a regression analysis implemented in QTL Express software was used. Evidence was found for the existence of QTL for guard hair length, guard hair thickness and density of wool...

  12. Effect of the Length of Traffic Flow Records on the Estimate of a Bridge Service Life

    Directory of Open Access Journals (Sweden)

    Krejsa Jan

    2016-12-01

    Full Text Available The service life of bridges is significantly affected by fatigue of used material induced by heavy vehicles. Therefore, precise determination of the vehicle weight is of crucial importance for the calculation of fatigue damage and the prediction of the bridge serviceability. This paper investigates accuracy of the determination of fatigue depending on the length of traffic flow recording. The presented data were obtained from the measurements carried out on a bridge of the Prague Highway Ring. The analysis reveals that the optimal length of traffic recording is about 30 days.

  13. Modelling of multiple short-length-scale stall cells in an axial compressor using evolved GMDH neural networks

    International Nuclear Information System (INIS)

    Amanifard, N.; Nariman-Zadeh, N.; Farahani, M.H.; Khalkhali, A.

    2008-01-01

    Over the past 15 years there have been several research efforts to capture the stall inception nature in axial flow compressors. However previous analytical models could not explain the formation of short-length-scale stall cells. This paper provides a new model based on evolved GMDH neural network for transient evolution of multiple short-length-scale stall cells in an axial compressor. Genetic Algorithms (GAs) are also employed for optimal design of connectivity configuration of such GMDH-type neural networks. In this way, low-pass filter (LPF) pressure trace near the rotor leading edge is modelled with respect to the variation of pressure coefficient, flow rate coefficient, and number of rotor rotations which are defined as inputs

  14. Telomere length and depression

    DEFF Research Database (Denmark)

    Wium-Andersen, Marie Kim; Ørsted, David Dynnes; Rode, Line

    2017-01-01

    BACKGROUND: Depression has been cross-sectionally associated with short telomeres as a measure of biological age. However, the direction and nature of the association is currently unclear. AIMS: We examined whether short telomere length is associated with depression cross-sectionally as well...... as prospectively and genetically. METHOD: Telomere length and three polymorphisms, TERT, TERC and OBFC1, were measured in 67 306 individuals aged 20-100 years from the Danish general population and associated with register-based attendance at hospital for depression and purchase of antidepressant medication....... RESULTS: Attendance at hospital for depression was associated with short telomere length cross-sectionally, but not prospectively. Further, purchase of antidepressant medication was not associated with short telomere length cross-sectionally or prospectively. Mean follow-up was 7.6 years (range 0...

  15. Immediate, short-, and long-term changes in tracheal stent diameter, length, and positioning after placement in dogs with tracheal collapse syndrome.

    Science.gov (United States)

    Raske, Matthew; Weisse, Chick; Berent, Allyson C; McDougall, Renee; Lamb, Kenneth

    2018-03-01

    Intraluminal tracheal stenting is a minimally invasive procedure shown to have variable degrees of success in managing clinical signs associated with tracheal collapse syndrome (CTCS) in dogs. Identify immediate post-stent changes in tracheal diameter, determine the extent of stent migration, and stent shortening after stent placement in the immediate-, short-, and long-term periods, and evaluate inter-observer reliability of radiographic measurements. Fifty client-owned dogs. Retrospective study in which medical records were reviewed in dogs with CTCS treated with an intraluminal tracheal stent. Data collected included signalment, location, and type of collapse, stent diameter and length, and post-stent placement radiographic follow-up times. Radiographs were used to obtain pre-stent tracheal measurements and post-stent placement measurements. Immediate mean percentage change was 5.14%, 5.49%, and 21.64% for cervical, thoracic inlet, and intra-thoracic tracheal diameters, respectively. Ultimate mean follow-up time was 446 days, with mean percentage change of 2.55%, 15.09%, and 8.65% for cervical, thoracic inlet, and intra-thoracic tracheal diameters, respectively. Initial mean stent length was 26.72% higher than nominal length and ultimate long-term tracheal mean stent shortening was only 9.90%. No significant stent migration was identified in the immediate, short-, or long-term periods. Good inter-observer agreement of radiographic measurements was found among observers of variable experience level. Use of an intraluminal tracheal stent for CTCS is associated with minimal stent shortening with no clinically relevant stent migration after fluoroscopic placement. Precise stent sizing and placement techniques likely play important roles in avoiding these reported complications. Copyright © 2018 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  16. Screening and treatment for short cervical length in pregnancy: a physician survey in the United States.

    Science.gov (United States)

    Martell, Bridget; DiBenedetti, Dana B; Weiss, Herman; Zhou, Xiaolei; Reynolds, Maria; Berghella, Vincenzo; Hassan, Sonia S

    2018-03-01

    To evaluate how physicians in the United States (US) screen for, define, and treat a short cervix to prevent preterm birth. This was a cross-sectional, web-based survey of 500 physicians treating pregnant patients with a short cervix in the US. Respondents' geographic region was monitored to ensure balance across the nine US Census divisions. Respondents were predominantly obstetrician/gynecologists (86%, 429/500; mean age 49 years). Physicians reported that a median of 90% of their pregnant patients undergo cervical length screening; 81% (407/500) use transvaginal ultrasound. Physicians consult multiple evidence sources to inform their patient care, most commonly clinical guidelines (83%; 413/500) and published research (70%; 349/500). Most physicians (98%; 490/500) reported treating pregnant patients with a short cervix; 95% (474/500) use synthetic and/or natural progestogen, alone or in combination with other treatment modalities. If reimbursement was not a concern, 47% of physicians (230/500) would choose vaginal progesterone as their preferred treatment to prevent preterm birth in all patients with a short cervix, and 45% (218/500) would choose a synthetic progestogen. US guidelines recommend transvaginal ultrasound for cervical length screening; 81% of physicians in this study reported using this method. Most physicians surveyed use progestogens to treat a short cervix, with approximately half choosing a synthetic progestin (45%) and half choosing natural progesterone (47%) as their preferred treatment, despite national guidelines recommending only vaginal natural progesterone for this indication. Additional physician education is required to implement current and best practices.

  17. Improved Fast, Deep Record Length, Time-Resolved Visible Spectroscopy of Plasmas Using Fiber Grids

    Science.gov (United States)

    Brockington, S.; Case, A.; Cruz, E.; Williams, A.; Witherspoon, F. D.; Horton, R.; Klauser, R.; Hwang, D.

    2017-10-01

    HyperV Technologies is developing a fiber-coupled, deep record-length, low-light camera head for performing high time resolution spectroscopy on visible emission from plasma events. By coupling the output of a spectrometer to an imaging fiber bundle connected to a bank of amplified silicon photomultipliers, time-resolved spectroscopic imagers of 100 to 1,000 pixels can be constructed. A second generation prototype 32-pixel spectroscopic imager employing this technique was constructed and successfully tested at the University of California at Davis Compact Toroid Injection Experiment (CTIX). Pixel performance of 10 Megaframes/sec with record lengths of up to 256,000 frames ( 25.6 milliseconds) were achieved. Pixel resolution was 12 bits. Pixel pitch can be refined by using grids of 100 μm to 1000 μm diameter fibers. Experimental results will be discussed, along with future plans for this diagnostic. Work supported by USDOE SBIR Grant DE-SC0013801.

  18. Investigation of the extraction of short diffusion lengths from simulated electron-beam induced current

    Energy Technology Data Exchange (ETDEWEB)

    Wee, D.; Parish, G.; Nener, B. [Microelectronics Research Group, The University of Western Australia, 35 Stirling Highway, 6009 Crawley (Perth) (Australia)

    2010-10-15

    This paper reports on the investigations via 2-D simulation into the accuracy of diffusion length extraction from scanning electron-beam induced current measurements when the diffusion length, L is very short. L is extracted by using the direct method proposed by Chan et al.[1] and later refined by Kurniawan and Ong[2] to take finite junction depth into account. The 2-D simulations were undertaken using Synopsys {sup registered} Sentaurus TCAD and a realistic electron-hole pair generation volume was created using CASINO v2.42[3], a Monte Carlo Scanning Electron Microscope interaction simulation software, and imported into Sentaurus. The voltage and diameter of the electron beam and diffusion length and surface recombination velocity of the semiconductor materials were varied in the simulations to determine the errors in the diffusion length extracted from the EBIC signals as a function of these parameters. The results of the simulation show that the accuracy of the method proposed in[1] is reasonably accurate and that the beam voltage and spot size do not have significant effects on the accuracy (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  19. Investigation of the extraction of short diffusion lengths from simulated electron-beam induced current

    International Nuclear Information System (INIS)

    Wee, D.; Parish, G.; Nener, B.

    2010-01-01

    This paper reports on the investigations via 2-D simulation into the accuracy of diffusion length extraction from scanning electron-beam induced current measurements when the diffusion length, L is very short. L is extracted by using the direct method proposed by Chan et al.[1] and later refined by Kurniawan and Ong[2] to take finite junction depth into account. The 2-D simulations were undertaken using Synopsys registered Sentaurus TCAD and a realistic electron-hole pair generation volume was created using CASINO v2.42[3], a Monte Carlo Scanning Electron Microscope interaction simulation software, and imported into Sentaurus. The voltage and diameter of the electron beam and diffusion length and surface recombination velocity of the semiconductor materials were varied in the simulations to determine the errors in the diffusion length extracted from the EBIC signals as a function of these parameters. The results of the simulation show that the accuracy of the method proposed in[1] is reasonably accurate and that the beam voltage and spot size do not have significant effects on the accuracy (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  20. Retrospective cohort clinical investigation of a dental implant with a narrow diameter and short length for the partial rehabilitation of extremely atrophic jaws.

    Science.gov (United States)

    Maló, Paulo S; de Araújo Nobre, Miguel A; Lopes, Armando V; Ferro, Ana S

    2017-01-01

    We investigated the short-term clinical outcomes of narrow-diameter short-length implants for the fixed-prosthetic partial rehabilitation of extremely resorbed jaws. Twenty-three patients requiring partial rehabilitations with narrow-platform short-length implants in any jaw were included in this study. In total, 30 implants 3.3 mm in diameter and 7 (n = 15 implants) or 8.5 (n = 15 implants) mm in length were inserted. The primary outcome measure was implant cumulative survival rate (CSR); the secondary outcome measures were marginal bone resorption at 1 and 3 years and the incidence of biologic and mechanical complications. Five patients (21.7%) with six implants (20%) were lost to follow-up. Two implants failed in two patients, yielding a CSR at 3 years of follow-up of 93.4%. The average (standard deviation) marginal bone resorption was 1.34 mm (0.95 mm) after the first year and 1.38 mm (0.78 mm) after the third year. Biologic complications occurred in three patients; mechanical complications occurred in three patients. Despite the limitations of the study, our findings show that the use of new narrow-diameter short-length implants for the rehabilitation of extremely atrophic regions is viable in the short-term, and can be considered a treatment alternative in extremely resorbed jaws.

  1. Short Rayleigh length free electron lasers

    Directory of Open Access Journals (Sweden)

    W. B. Colson

    2006-03-01

    Full Text Available Conventional free electron laser (FEL oscillators minimize the optical mode volume around the electron beam in the undulator by making the resonator Rayleigh length about one third to one half of the undulator length. This maximizes gain and beam-mode coupling. In compact configurations of high-power infrared FELs or moderate power UV FELs, the resulting optical intensity can damage the resonator mirrors. To increase the spot size and thereby reduce the optical intensity at the mirrors below the damage threshold, a shorter Rayleigh length can be used, but the FEL interaction is significantly altered. We model this interaction using a coordinate system that expands with the rapidly diffracting optical mode from the ends of the undulator to the mirrors. Simulations show that the interaction of the strongly focused optical mode with a narrow electron beam inside the undulator distorts the optical wave front so it is no longer in the fundamental Gaussian mode. The simulations are used to study how mode distortion affects the single-pass gain in weak fields, and the steady-state extraction in strong fields.

  2. Describing the interannual variability of precipitation with the derived distribution approach: effects of record length and resolution

    Directory of Open Access Journals (Sweden)

    C. I. Meier

    2016-10-01

    Full Text Available Interannual variability of precipitation is traditionally described by fitting a probability model to yearly precipitation totals. There are three potential problems with this approach: a long record (at least 25–30 years is required in order to fit the model, years with missing rainfall data cannot be used, and the data need to be homogeneous, i.e., one has to assume stationarity. To overcome some of these limitations, we test an alternative methodology proposed by Eagleson (1978, based on the derived distribution (DD approach. It allows estimation of the probability density function (pdf of annual rainfall without requiring long records, provided that continuously gauged precipitation data are available to derive external storm properties. The DD approach combines marginal pdfs for storm depths and inter-arrival times to obtain an analytical formulation of the distribution of annual precipitation, under the simplifying assumptions of independence between events and independence between storm depth and time to the next storm. Because it is based on information about storms and not on annual totals, the DD can make use of information from years with incomplete data; more importantly, only a few years of rainfall measurements should suffice to estimate the parameters of the marginal pdfs, at least at locations where it rains with some regularity. For two temperate locations in different climates (Concepción, Chile, and Lugano, Switzerland, we randomly resample shortened time series to evaluate in detail the effects of record length on the DD, comparing the results with the traditional approach of fitting a normal (or lognormal distribution. Then, at the same two stations, we assess the biases introduced in the DD when using daily totalized rainfall, instead of continuously gauged data. Finally, for randomly selected periods between 3 and 15 years in length, we conduct full blind tests at 52 high-quality gauging stations in Switzerland

  3. Short Note Some additional breeding records for birds in Angola ...

    African Journals Online (AJOL)

    Short Note Some additional breeding records for birds in Angola. W Richard J Dean, Suzanne J Milton. Abstract. No abstract. Ostrich 2007, 78(3): 645–647. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · http://dx.doi.org/10.2989/OSTRICH.2007.78.3.13.324.

  4. Estimating length of avian incubation and nestling stages in afrotropical forest birds from interval-censored nest records

    Science.gov (United States)

    Stanley, T.R.; Newmark, W.D.

    2010-01-01

    In the East Usambara Mountains in northeast Tanzania, research on the effects of forest fragmentation and disturbance on nest survival in understory birds resulted in the accumulation of 1,002 nest records between 2003 and 2008 for 8 poorly studied species. Because information on the length of the incubation and nestling stages in these species is nonexistent or sparse, our objectives in this study were (1) to estimate the length of the incubation and nestling stage and (2) to compute nest survival using these estimates in combination with calculated daily survival probability. Because our data were interval censored, we developed and applied two new statistical methods to estimate stage length. In the 8 species studied, the incubation stage lasted 9.6-21.8 days and the nestling stage 13.9-21.2 days. Combining these results with estimates of daily survival probability, we found that nest survival ranged from 6.0% to 12.5%. We conclude that our methodology for estimating stage lengths from interval-censored nest records is a reasonable and practical approach in the presence of interval-censored data. ?? 2010 The American Ornithologists' Union.

  5. Construction of Short-Length High-Rates LDPC Codes Using Difference Families

    Directory of Open Access Journals (Sweden)

    Deny Hamdani

    2010-10-01

    Full Text Available Low-density parity-check (LDPC code is linear-block error-correcting code defined by sparse parity-check matrix. It is decoded using the massage-passing algorithm, and in many cases, capable of outperforming turbo code. This paper presents a class of low-density parity-check (LDPC codes showing good performance with low encoding complexity. The code is constructed using difference families from  combinatorial design. The resulting code, which is designed to have short code length and high code rate, can be encoded with low complexity due to its quasi-cyclic structure, and performs well when it is iteratively decoded with the sum-product algorithm. These properties of LDPC code are quite suitable for applications in future wireless local area network.

  6. The short mean length of stay of post-emergency geriatric units is associated with the rate of early readmission in frail elderly.

    Science.gov (United States)

    Traissac, Thalie; Videau, Marie-Neige; Bourdil, Marie-José; Bourdel-Marchasson, Isabelle; Salles, Nathalie

    2011-06-01

    Specific postemergency short-stay geriatric units may decrease length of hospital stay, functional decline, and early readmission rates. The aim of this study was to evaluate risk factors of early rehospitalization in a shortstay geriatric unit. This study was a prospective observational study comprising over one year patients aged over 75 years, admitted to the post-emergency short-stay geriatric unit (Hôpital Saint André, Bordeaux, France) and discharged home. Socio-demographic data, length of hospital stay, and a standardized geriatric assessment were collected for all patients. One month after home discharge, patients were followed-up by phone, and the hospital readmission rate was calculated. descriptive, unvaried and multivariate analyses were carried out. A total of 476 patients were included in this study (mean age 86.5±6 yrs; 154 men, 322 women). Mean length of stay in the post-emergency short-stay geriatric unit was 6.3±2.7 days, and a total of 68 (14.3%) patients were readmitted within one month after home discharge. The readmission rate was associated with a diagnosis of delirium (Odds Ratio (OR) 1.9; 95% CI 1.1-3.3; p=0.02), mean length of stay exceeding 6 days (OR 1.9, 95% CI 1.1-3.5; p=0.02), and decision of home discharge (OR 2.4; 95% CI 1.4-4.1; p=0.002). Short mean lengths of stay were not considered as a risk factor for readmissions within one month, even in frail, dependent, hospitalized elderly persons.

  7. Reliability and short-term intra-individual variability of telomere length measurement using monochrome multiplexing quantitative PCR.

    Directory of Open Access Journals (Sweden)

    Sangmi Kim

    Full Text Available Studies examining the association between telomere length and cancer risk have often relied on measurement of telomere length from a single blood draw using a real-time PCR technique. We examined the reliability of telomere length measurement using sequential samples collected over a 9-month period.Relative telomere length in peripheral blood was estimated using a single tube monochrome multiplex quantitative PCR assay in blood DNA samples from 27 non-pregnant adult women (aged 35 to 74 years collected in 7 visits over a 9-month period. A linear mixed model was used to estimate the components of variance for telomere length measurements attributed to variation among women and variation between time points within women. Mean telomere length measurement at any single visit was not significantly different from the average of 7 visits. Plates had a significant systematic influence on telomere length measurements, although measurements between different plates were highly correlated. After controlling for plate effects, 64% of the remaining variance was estimated to be accounted for by variance due to subject. Variance explained by time of visit within a subject was minor, contributing 5% of the remaining variance.Our data demonstrate good short-term reliability of telomere length measurement using blood from a single draw. However, the existence of technical variability, particularly plate effects, reinforces the need for technical replicates and balancing of case and control samples across plates.

  8. [Deep brain recording and length of surgery in stereotactic and functional neurosurgery for movement disorders].

    Science.gov (United States)

    Teijeiro, Juan; Macías, Raúl J; Maragoto, Carlos; García, Iván; Alvarez, Mario; Quintanal, Nelson E

    2014-01-01

    Our objectives were to study the length of multi-unit recordings (MURs) of brain activity in 20 years of movement disorder neurosurgeries and to determine the number of times in which it was necessary for the teams using single-unit recording (SUR) to explore all the electrode tracks in the simultaneously recorded sites (SRS). This was a retrospective descriptive statistical analysis of MUR length on 4,296 tracks in 952 surgeries. The exclusion criteria were: tracks with fewer than 5 recorded signals, tracks that had a signal length different from the habitual 2s, or there being unusual situations not related to the MUR, as well as the first 20 surgeries of each surgical target. This yielded a total of 3,448 tracks in 805 surgeries. We also determined the number of the total 952 surgeries in which all the tracks in the SURs of the SRS were explored. The mean and its confidence interval (P=.05) of time per MUR track were 5.49±0.16min in subthalamic nucleus surgery, 8.82±0.24min in the medial or internal globus pallidus) and 18.51±1.31min in the ventral intermediate nucleus of the thalamus. For the total sum of tracks per surgery, in 75% of cases the total time was less than 39min in subthalamic nucleus, almost 42min in the medial or internal globus pallidus and less than 1h and 17min in ventral intermediate nucleus of the thalamus. All the tracks in the SUR SRS were explored in only 4.2% of the surgeries. The impact of MUR on surgical time is acceptable for this guide in objective localization for surgical targets, without having to use several simultaneous electrodes (not all indispensable in most of the cases). Consequently, there is less risk for the patient. Copyright © 2013 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  9. Comparison of stethoscope bell and diaphragm, and of stethoscope tube length, for clinical blood pressure measurement.

    Science.gov (United States)

    Liu, Chengyu; Griffiths, Clive; Murray, Alan; Zheng, Dingchang

    2016-06-01

    This study investigated the effect of stethoscope side and tube length on auscultatory blood pressure (BP) measurement. Thirty-two healthy participants were studied. For each participant, four measurements with different combinations of stethoscope characteristics (bell or diaphragm side, standard or short tube length) were each recorded at two repeat sessions, and eight Korotkoff sound recordings were played twice on separate days to one experienced listener to determine the systolic and diastolic BPs (SBP and DBP). Analysis of variance was carried out to study the measurement repeatability between the two repeat sessions and between the two BP determinations on separate days, as well as the effects of stethoscope side and tube length. There was no significant paired difference between the repeat sessions and between the repeat determinations for both SBP and DBP (all P-values>0.10, except the repeat session for SBP using short tube and diaphragm). The key result was that there was a small but significantly higher DBP on using the bell in comparison with the diaphragm (0.66 mmHg, P=0.007), and a significantly higher SBP on using the short tube in comparison with the standard length (0.77 mmHg, P=0.008). This study shows that stethoscope characteristics have only a small, although statistically significant, influence on clinical BP measurement. Although this helps understand the measurement technique and resolves questions in the published literature, the influence is not clinically significant.

  10. Information, polarization and term length in democracy

    DEFF Research Database (Denmark)

    Schultz, Christian

    2008-01-01

    This paper considers term lengths in a representative democracy where the political issue divides the population on the left-right scale. Parties are ideologically different and better informed about the consequences of policies than voters are. A short term length makes the government more...... accountable, but the re-election incentive leads to policy-distortion as the government seeks to manipulate swing voters' beliefs to make its ideology more popular. This creates a trade-off: A short term length improves accountability but gives distortions. A short term length is best for swing voters when...

  11. Elasticity of short DNA molecules: theory and experiment for contour lengths of 0.6-7 microm.

    Science.gov (United States)

    Seol, Yeonee; Li, Jinyu; Nelson, Philip C; Perkins, Thomas T; Betterton, M D

    2007-12-15

    The wormlike chain (WLC) model currently provides the best description of double-stranded DNA elasticity for micron-sized molecules. This theory requires two intrinsic material parameters-the contour length L and the persistence length p. We measured and then analyzed the elasticity of double-stranded DNA as a function of L (632 nm-7.03 microm) using the classic solution to the WLC model. When the elasticity data were analyzed using this solution, the resulting fitted value for the persistence length p(wlc) depended on L; even for moderately long DNA molecules (L = 1300 nm), this apparent persistence length was 10% smaller than its limiting value for long DNA. Because p is a material parameter, and cannot depend on length, we sought a new solution to the WLC model, which we call the "finite wormlike chain (FWLC)," to account for effects not considered in the classic solution. Specifically we accounted for the finite chain length, the chain-end boundary conditions, and the bead rotational fluctuations inherent in optical trapping assays where beads are used to apply the force. After incorporating these corrections, we used our FWLC solution to generate force-extension curves, and then fit those curves with the classic WLC solution, as done in the standard experimental analysis. These results qualitatively reproduced the apparent dependence of p(wlc) on L seen in experimental data when analyzed with the classic WLC solution. Directly fitting experimental data to the FWLC solution reduces the apparent dependence of p(fwlc) on L by a factor of 3. Thus, the FWLC solution provides a significantly improved theoretical framework in which to analyze single-molecule experiments over a broad range of experimentally accessible DNA lengths, including both short (a few hundred nanometers in contour length) and very long (microns in contour length) molecules.

  12. Short Length of Stay After Elective Transfemoral Transcatheter Aortic Valve Replacement is Not Associated With Increased Early or Late Readmission Risk.

    Science.gov (United States)

    Sud, Maneesh; Qui, Feng; Austin, Peter C; Ko, Dennis T; Wood, David; Czarnecki, Andrew; Patel, Vaidehi; Lee, Douglas S; Wijeysundera, Harindra C

    2017-04-24

    Elderly patients undergoing transcatheter aortic valve replacement (TAVR) are at risk of hospital readmission postprocedure. It is not known whether the index hospital length of stay and, specifically, early discharge post-TAVR is associated with an increased risk of readmission. We hypothesized a nonlinear relationship whereby both short and long lengths of stay were associated with increased readmission risk. We performed a retrospective multicenter cohort analysis of patients undergoing elective transfemoral TAVR and surviving to discharge between January 2007 and March 2014. The exposure variable was hospital length of stay measured from the procedure date to the date of discharge and modeled as a continuous variable in a multivariable cause-specific Cox regression. Main outcome measures were 30-day and 1-year all-cause readmissions. The study population consisted of 709 patients with a median length of stay of 6 days (interquartile range, 4-8). At 30-days and 1-year, 13.5% and 44.0% of patients were readmitted, respectively. Although post-TAVR length of stay was not associated with 30-day all-cause readmissions ( P =0.925), there existed a significant association with 1-year readmission ( P =0.010) after adjustment for baseline clinical variables. The association between post-TAVR length of stay and 1-year readmission was linear ( P =0.549 for nonlinearity) with no evidence supporting an increased readmission risk for shorter length of stays. Among elderly survivors of elective transfemoral TAVR, a short postprocedural length of stay was not associated with an increased risk readmission within 30 days or 1 year. However, the risk of 1-year readmission increased with longer post-TAVR lengths of stay. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  13. Adjustable, short focal length permanent-magnet quadrupole based electron beam final focus system

    Directory of Open Access Journals (Sweden)

    J. K. Lim

    2005-07-01

    Full Text Available Advanced high-brightness beam applications such as inverse-Compton scattering (ICS depend on achieving of ultrasmall spot sizes in high current beams. Modern injectors and compressors enable the production of high-brightness beams having needed short bunch lengths and small emittances. Along with these beam properties comes the need to produce tighter foci, using stronger, shorter focal length optics. An approach to creating such strong focusing systems using high-field, small-bore permanent-magnet quadrupoles (PMQs is reported here. A final-focus system employing three PMQs, each composed of 16 neodymium iron boride sectors in a Halbach geometry has been installed in the PLEIADES ICS experiment. The field gradient in these PMQs is 560   T/m, the highest ever reported in a magnetic optics system. As the magnets are of a fixed field strength, the focusing system is tuned by adjusting the position of the three magnets along the beam line axis, in analogy to familiar camera optics. This paper discusses the details of the focusing system, simulation, design, fabrication, and experimental procedure in creating ultrasmall beams at PLEIADES.

  14. Does length or neighborhood size cause the word length effect?

    Science.gov (United States)

    Jalbert, Annie; Neath, Ian; Surprenant, Aimée M

    2011-10-01

    Jalbert, Neath, Bireta, and Surprenant (2011) suggested that past demonstrations of the word length effect, the finding that words with fewer syllables are recalled better than words with more syllables, included a confound: The short words had more orthographic neighbors than the long words. The experiments reported here test two predictions that would follow if neighborhood size is a more important factor than word length. In Experiment 1, we found that concurrent articulation removed the effect of neighborhood size, just as it removes the effect of word length. Experiment 2 demonstrated that this pattern is also found with nonwords. For Experiment 3, we factorially manipulated length and neighborhood size, and found only effects of the latter. These results are problematic for any theory of memory that includes decay offset by rehearsal, but they are consistent with accounts that include a redintegrative stage that is susceptible to disruption by noise. The results also confirm the importance of lexical and linguistic factors on memory tasks thought to tap short-term memory.

  15. A comparison of computerized adaptive testing and fixed-length short forms for the Prosthetic Limb Users Survey of Mobility (PLUS-MTM).

    Science.gov (United States)

    Amtmann, Dagmar; Bamer, Alyssa M; Kim, Jiseon; Bocell, Fraser; Chung, Hyewon; Park, Ryoungsun; Salem, Rana; Hafner, Brian J

    2017-09-01

    New health status instruments can be administered by computerized adaptive test or short forms. The Prosthetic Limb Users Survey of Mobility (PLUS-M TM ) is a self-report measure of mobility for prosthesis users with lower limb loss. This study used the PLUS-M to examine advantages and disadvantages of computerized adaptive test and short forms. To compare scores obtained from computerized adaptive test to scores obtained from fixed-length short forms (7-item and 12-item) in order to provide guidance to researchers and clinicians on how to select the best form of administration for different uses. Cross-sectional, observational study. Individuals with lower limb loss completed the PLUS-M by computerized adaptive test and short forms. Administration time, correlations between the scores, and standard errors were compared. Scores and standard errors from the computerized adaptive test, 7-item short form, and 12-item short form were highly correlated and all forms of administration were efficient. Computerized adaptive test required less time to administer than either paper or electronic short forms; however, time savings were minimal compared to the 7-item short form. Results indicate that the PLUS-M computerized adaptive test is most efficient, and differences in scores between administration methods are minimal. The main advantage of the computerized adaptive test was more reliable scores at higher levels of mobility compared to short forms. Clinical relevance Health-related item banks, like the Prosthetic Limb Users Survey of Mobility (PLUS-M TM ), can be administered by computerized adaptive testing (CAT) or as fixed-length short forms (SFs). Results of this study will help clinicians and researchers decide whether they should invest in a CAT administration system or whether SFs are more appropriate.

  16. Gnomon shadow lengths recorded in the Zhoubi Suanjing: the earliest meridian observations in China?

    International Nuclear Information System (INIS)

    Li Yong; Sun Xiaochun

    2009-01-01

    The Zhoubi Suanjing, one of the most important ancient Chinese books on mathematical astronomy, was compiled about 100 BC in the Western Han dynasty (BC 206 - AD 23). We study the gnomon shadow lengths for the 24 solar terms as recorded in the book. Special attention is paid to the so-called law of 'cun qian li', which says the shadow length of a gnomon of 8 chi (about 1.96 m) high will increase (or decrease) 1 cun (1/10 chi) for every 1000 li (roughly 400 km) the gnomon moves northward (or southward). From these data, one can derive the time and location of the observations. The results, however, do not fit historical facts. We suggest that compilers of the Zhoubi Suanjing must have modified the original data according to the law of 'cun qian li'. Through reversing the situation, we recovered the original data, our analysis of which reveals the best possible observation time as 564 BC and the location of observation as 35.78 deg. N latitude. We conclude that this must be the earliest records of solar meridian observations in China. In the meantime, we give the errors of solar altitudes for the 24 solar terms. The average deviation is 5.22 deg., and the mean absolute deviation is 5.52 deg., signifying the accuracy of astronomical calculations from that time.

  17. The fossil record of South American short-faced bears (Ursidae, Tremarctinae)

    OpenAIRE

    Bond, Mariano; Tonni, Eduardo Pedro; Soibelzon, Leopoldo Héctor

    2005-01-01

    The present study includes a review of the geographic and stratigraphic distribution of short-faced bears (Ursidae, Tremarctinae) in South America. In addition, the authors discuss biogeographic hypotheses regarding the origin of South American tremarctines. The Tremarctinae subfamily is distributed exclusively in America, from Alaska to southern Patagonia. Its biochron comprises the temporal lapse between Late Miocene and recent times; the first record of Tremarctinae in North America corres...

  18. Brain SPECT with short focal-length cone-beam collimation

    International Nuclear Information System (INIS)

    Park, Mi-Ae; Moore, Stephen C.; Kijewski, Marie Foley

    2005-01-01

    Single-photon emission-computed tomography (SPECT) imaging of deep brain structures is compromised by loss of photons due to attenuation. We have previously shown that a centrally peaked collimator sensitivity function can compensate for this phenomenon, increasing sensitivity over most of the brain. For dual-head instruments, parallel-hole collimators cannot provide variable sensitivity without simultaneously degrading spatial resolution near the center of the brain; this suggests the use of converging collimators. We have designed collimator pairs for dual-head SPECT systems to increase sensitivity, particularly in the center of the brain, and compared the new collimation approach to existing approaches on the basis of performance in estimating activity concentration of small structures at various locations in the brain. The collimator pairs we evaluated included a cone-beam collimator, for increased sensitivity, and a fan-beam collimator, for data sufficiency. We calculated projections of an ellipsoidal uniform background, with 0.9-cm-radius spherical lesions at several locations in the background. From these, we determined ideal signal-to-noise ratios (SNR CRB ) for estimation of activity concentration within the spheres, based on the Cramer-Rao lower bound on variance. We also reconstructed, by an ordered-subset expectation-maximization (OS-EM) procedure, images of this phantom, as well as of the Zubal brain phantom, to allow visual assessment and to ensure that they were free of artifacts. The best of the collimator pairs evaluated comprised a cone-beam collimator with 20 cm focal length, for which the focal point is inside the brain, and a fan-beam collimator with 40 cm focal length. This pair yielded increased SNR CRB , compared to the parallel-parallel pair, throughout the imaging volume. The factor by which SNR CRB increased ranged from 1.1 at the most axially extreme location to 3.5 at the center. The gains in SNR CRB were relatively robust to mismatches

  19. The length-weight and length-length relationships of bluefish, Pomatomus saltatrix (Linnaeus, 1766) from Samsun, middle Black Sea region

    OpenAIRE

    Özpiçak, Melek; Saygın, Semra; Polat, Nazmi

    2017-01-01

    In this study, length-weight relationship (LWR) and length-length relationship (LLR) of bluefish,Pomatomus saltatrix were determined. A total of 125 specimens were sampled from Samsun, themiddle Black Sea in 2014 fishing season. Bluefish specimens were monthly collected fromcommercial fishing boats from October to December 2014. All captured individuals (N=125) weremeasured to the nearest 0.1 cm for total, fork and standard lengths. The weight of each fish (W)was recorded to the nearest 0.01 ...

  20. The influence of length of relationship, gender and age on the relationship intention of short-term insurance clients: an exploratory study

    Directory of Open Access Journals (Sweden)

    Derik Steyn

    2011-09-01

    insurance industry completed self-administered questionnaires. Findings indicate that, for a group of high relationship-intention clients of a short-term insurance organisation, no practically significant discrimination exists on any of the relationship-intention constructs for clients’ length of relationship, gender or age.

  1. Word Length Effects in Long-Term Memory

    Science.gov (United States)

    Tehan, Gerald; Tolan, Georgina Anne

    2007-01-01

    The word length effect has been a central feature of theorising about immediate memory. The notion that short-term memory traces rapidly decay unless refreshed by rehearsal is based primarily upon the finding that serial recall for short words is better than that for long words. The decay account of the word length effect has come under pressure…

  2. Telomere length analysis.

    Science.gov (United States)

    Canela, Andrés; Klatt, Peter; Blasco, María A

    2007-01-01

    Most somatic cells of long-lived species undergo telomere shortening throughout life. Critically short telomeres trigger loss of cell viability in tissues, which has been related to alteration of tissue function and loss of regenerative capabilities in aging and aging-related diseases. Hence, telomere length is an important biomarker for aging and can be used in the prognosis of aging diseases. These facts highlight the importance of developing methods for telomere length determination that can be employed to evaluate telomere length during the human aging process. Telomere length quantification methods have improved greatly in accuracy and sensitivity since the development of the conventional telomeric Southern blot. Here, we describe the different methodologies recently developed for telomere length quantification, as well as their potential applications for human aging studies.

  3. Computer game as a tool for training the identification of phonemic length.

    Science.gov (United States)

    Pennala, Riitta; Richardson, Ulla; Ylinen, Sari; Lyytinen, Heikki; Martin, Maisa

    2014-12-01

    Computer-assisted training of Finnish phonemic length was conducted with 7-year-old Russian-speaking second-language learners of Finnish. Phonemic length plays a different role in these two languages. The training included game activities with two- and three-syllable word and pseudo-word minimal pairs with prototypical vowel durations. The lowest accuracy scores were recorded for two-syllable words. Accuracy scores were higher for the minimal pairs with larger rather than smaller differences in duration. Accuracy scores were lower for long duration than for short duration. The ability to identify quantity degree was generalized to stimuli used in the identification test in two of the children. Ideas for improving the game are introduced.

  4. Estimation of optimal hologram recording modes on photothermal materials

    Science.gov (United States)

    Dzhamankyzov, Nasipbek Kurmanalievich; Ismanov, Yusupzhan Khakimzhanovich; Zhumaliev, Kubanychbek Myrzabekovich; Alymkulov, Samsaly Amanovich

    2018-01-01

    A theoretical analysis of the hologram recording process on photothermal media to estimate the required laser radiation power for the information recording as the function of the spatial frequency and radiation exposure duration is considered. Results of the analysis showed that materials with a low thermal diffusivity are necessary to increase the recording density in these media and the recording should be performed with short pulses to minimize the thermal diffusion length. A solution for the heat conduction equation for photothermal materials heated by an interference laser field was found. The solution obtained allows one to determine the required value of the recording temperature for given spatial frequencies, depending on the thermal physical parameters of the medium and on the power and duration of the heating radiation.

  5. Measurement of short bunches

    International Nuclear Information System (INIS)

    Wang, D.X.

    1996-01-01

    In recent years, there has been increasing interest in short electron bunches for different applications such as short wavelength FELs, linear colliders, and advanced accelerators such as laser or plasma wakefield accelerators. One would like to meet various requirements such as high peak current, low momentum spread, high luminosity, small ratio of bunch length to plasma wavelength, and accurate timing. Meanwhile, recent development and advances in RF photoinjectors and various bunching schemes make it possible to generate very short electron bunches. Measuring the longitudinal profile and monitoring bunch length are critical to understand the bunching process and longitudinal beam dynamics, and to commission and operate such short bunch machines. In this paper, several commonly used measurement techniques for subpicosecond bunches and their relative advantages and disadvantages are discussed. As examples, bunch length related measurements at Jefferson Lab are presented. At Jefferson Lab, bunch lengths as short as 84 fs have been systematically measured using a zero-phasing technique. A highly sensitive Coherent Synchrotron Radiation (CSR) detector has been developed to noninvasively monitor bunch length for low charge bunches. Phase transfer function measurements provide a means of correcting RF phase drifts and reproducing RF phases to within a couple of tenths of a degree. The measurement results are in excellent agreement with simulations. A comprehensive bunch length control scheme is presented. (author)

  6. Measurement of short bunches

    International Nuclear Information System (INIS)

    Wang, D.X.

    1996-01-01

    In recent years, there has been increasing interest in short electron bunches for different applications such as short wavelength FELs, linear colliders, and advanced accelerators such as laser or plasma wakefield accelerators. One would like to meet various requirements such as high peak current, low momentum spread, high luminosity, small ratio of bunch length to plasma wavelength, and accurate timing. Meanwhile, recent development and advances in RF photoinjectors and various bunching schemes make it possible to generate very short electron bunches. Measuring the longitudinal profile and monitoring bunch length are critical to understand the bunching process and longitudinal beam dynamics, and to commission and operate such short bunch machines. In this paper, several commonly used measurement techniques for subpicosecond bunches and their relative advantages and disadvantages are discussed. As examples, bunch length related measurements at Jefferson lab are presented. At Jefferson Lab, bunch lengths s short as 84 fs have been systematically measured using a zero-phasing technique. A highly sensitive Coherent Synchrotron Radiation (CSR) detector has been developed to noninvasively monitor bunch length for low charge bunches. Phase transfer function measurements provide a means of correcting RF phase drifts and reproducing RF phases to within a couple of tenths of a degree. The measurement results are in excellent agreement with simulations. A comprehensive bunch length control scheme is presented

  7. Total hip arthroplasty using a short-stem prosthesis: restoration of hip anatomy.

    Science.gov (United States)

    Amenabar, Tomas; Marimuthu, Kanniraj; Hawdon, Gabrielle; Gildone, Alessandro; McMahon, Stephen

    2015-04-01

    To evaluate hip parameters such as vertical centre of rotation (VCR), horizontal centre of rotation (HCR), femoral offset, and leg length after total hip arthroplasty (THA) using the Nanos short-stem prosthesis. Medical records of 73 men and 74 women aged 25 to 92 (mean, 63) years who underwent THA using the Nanos short-stem prosthesis by a single surgeon were reviewed. Prior to the surgery, the optimal cup and stem size, head length, and level of the neck osteotomy were determined using radiographs. Intra-operatively, the leg length and femoral offset were checked, and the level of neck resection and head length were adjusted. VCR, HCR, femoral offset, and leg length of the operated and contralateral sides were compared. Functional outcomes were assessed using the Harris Hip Score (HHS). Compared with the normal contralateral hips, the operated hips had a mean increase of 0.4 mm in VCR (p=0.032), a mean decrease of 1.4 mm in HCR (p=0.027), a mean increase of 0.6 mm in femoral offset (p=0.043), and a mean increase of 0.36 mm in leg length (p=0.035). For these respective parameters, the difference between the normal contralateral side and the operated side was within 5 mm in 89%, 80%, 71%, and 96% of patients. The HHS improved from a mean of 53 to 91 at one year (pNanos short-stem prosthesis enabled restoration of hip anatomy (VCR, HCR, femoral offset, and leg length).

  8. Record Charge Carrier Diffusion Length in Colloidal Quantum Dot Solids via Mutual Dot-To-Dot Surface Passivation.

    Science.gov (United States)

    Carey, Graham H; Levina, Larissa; Comin, Riccardo; Voznyy, Oleksandr; Sargent, Edward H

    2015-06-03

    Through a combination of chemical and mutual dot-to-dot surface passivation, high-quality colloidal quantum dot solids are fabricated. The joint passivation techniques lead to a record diffusion length for colloidal quantum dots of 230 ± 20 nm. The technique is applied to create thick photovoltaic devices that exhibit high current density without losing fill factor. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. HAMSTRING ARCHITECTURAL AND FUNCTIONAL ADAPTATIONS FOLLOWING LONG VS. SHORT MUSCLE LENGTH ECCENTRIC TRAINING

    Directory of Open Access Journals (Sweden)

    Kenny Guex

    2016-08-01

    Full Text Available Most common preventive eccentric-based exercises, such as Nordic hamstring do not include any hip flexion. So, the elongation stress reached is lower than during the late swing phase of sprinting. The aim of this study was to assess the evolution of hamstring architectural (fascicle length and pennation angle and functional (concentric and eccentric optimum angles and concentric and eccentric peak torques parameters following a 3-week eccentric resistance program performed at long (LML versus short muscle length (SML. Both groups performed eight sessions of 3-5x8 slow maximal eccentric knee extensions on an isokinetic dynamometer: the SML group at 0° and the LML group at 80° of hip flexion. Architectural parameters were measured using ultrasound imaging and functional parameters using the isokinetic dynamometer. The fascicle length increased by 4.9% (p<0.01, medium effect size in the SML and by 9.3% (p<0.001, large effect size in the LML group. The pennation angle did not change (p=0.83 in the SML and tended to decrease by 0.7° (p=0.09, small effect size in the LML group. The concentric optimum angle tended to decrease by 8.8° (p=0.09, medium effect size in the SML and by 17.3° (p<0.01, large effect size in the LML group. The eccentric optimum angle did not change (p=0.19, small effect size in the SML and tended to decrease by 10.7° (p=0.06, medium effect size in the LML group. The concentric peak torque did not change in the SML (p=0.37 and the LML (p=0.23 groups, whereas eccentric peak torque increased by 12.9% (p<0.01, small effect size and 17.9% (p<0.001, small effect size in the SML and the LML group, respectively. No group-by-time interaction was found for any parameters. A correlation was found between the training-induced change in fascicle length and the change in concentric optimum angle (r=-0.57, p<0.01. These results suggest that performing eccentric exercises lead to several architectural and functional adaptations. However

  10. Methods for stable recording of short-circuit current in a Na+-transporting epithelium.

    Science.gov (United States)

    Gondzik, Veronika; Awayda, Mouhamed S

    2011-07-01

    Epithelial Na(+) transport as measured by a variety of techniques, including the short-circuit current technique, has been described to exhibit a "rundown" phenomenon. This phenomenon manifests as time-dependent decrease of current and resistance and precludes the ability to carry out prolonged experiments aimed at examining the regulation of this transport. We developed methods for prolonged stable recordings of epithelial Na(+) transport using modifications of the short-circuit current technique and commercial Ussing-type chambers. We utilize the polarized MDCK cell line expressing the epithelial Na(+) channel (ENaC) to describe these methods. Briefly, existing commercial chambers were modified to allow continuous flow of Ringer solution and precise control of such flow. Chamber manifolds and associated plumbing were modified to allow precise temperature clamp preventing temperature oscillations. Recording electrodes were modified to eliminate the use of KCl and prevent membrane depolarization from KCl leakage. Solutions utilized standard bicarbonate-based buffers, but all gasses were prehydrated to clamp buffer osmolarity. We demonstrate that these modifications result in measurements of current and resistance that are stable for at least 2 h. We further demonstrate that drifts in osmolarity similar to those obtained before prior to our modifications can lead to a decrease of current and resistance similar to those attributed to rundown.

  11. Short fetal leukocyte telomere length and preterm prelabor rupture of the membranes.

    Directory of Open Access Journals (Sweden)

    Ramkumar Menon

    Full Text Available BACKGROUND: Rupture of the fetal membranes is a common harbinger of imminent labor and delivery. Telomere shortening is a surrogate for oxidative stress (OS and senescence. Fetal leukocyte and placental membrane DNA telomere lengths were evaluated to determine their association with preterm prelabor rupture of the membranes (pPROM or spontaneous preterm births with intact membranes (PTB, compared to term birth. METHODS: Telomere lengths were quantified in cord blood leukocytes (n = 133 from three major groups: 1 pPROM (n = 28, 2 PTB (n = 69 and 3 uncomplicated full term births (controls, n = 35, using real-time quantitative PCR. Placental membrane specimens (n = 18 were used to correlate fetal leukocyte and placental telomere lengths. Telomere length differences among the groups were analyzed by ANOVA. Pearson correlation coefficients determined relationships between leukocyte and placental membrane telomere lengths. RESULTS: In pregnancies with intact membranes, fetal leukocyte telomere length was inversely proportional to gestational age. The mean telomere length decreased as gestation progressed, with the shortest at term. pPROM had telomere lengths (9962 ± 3124 bp that were significantly shorter than gestational age-matched PTB (11546 ± 4348 bp, p = 0.04, but comparable to term births (9011 ± 2497 bp, p = 0.31. Secondary analyses revealed no effects of race (African American vs. Caucasian or intraamniotic infection on telomere length. A strong Pearson's correlation was noted between fetal leukocyte and placental membrane telomere lengths (ρ = 0.77; p<0.01. CONCLUSIONS: Fetal leukocyte telomere length is reduced in pPROM compared to PTB but is similar to term births. pPROM represents a placental membrane disease likely mediated by OS-induced senescence.

  12. The length-weight and length-length relationships of bluefish, Pomatomus saltatrix (Linnaeus, 1766 from Samsun, middle Black Sea region

    Directory of Open Access Journals (Sweden)

    Melek Özpiçak

    2017-10-01

    Full Text Available In this study, length-weight relationship (LWR and length-length relationship (LLR of bluefish, Pomatomus saltatrix were determined. A total of 125 specimens were sampled from Samsun, the middle Black Sea in 2014 fishing season. Bluefish specimens were monthly collected from commercial fishing boats from October to December 2014. All captured individuals (N=125 were measured to the nearest 0.1 cm for total, fork and standard lengths. The weight of each fish (W was recorded to the nearest 0.01 g. According to results of analyses, there were no statistically significant differences between sexes in term of length and weight (P˃0.05. The minimum and maximum total, fork and standard lengths of bluefish ranged between 13.5-23.6 cm, 12.50-21.80 cm and 10.60-20.10 cm, respectively. The equation of length-weight relationship were calculated as W=0.008TL3.12 (r2>0.962. Positive allometric growth was observed for bluefish (b>3. Length-length relationship was also highly significant (P<0.001 with coefficient of determination (r2 ranging from 0.916 to 0.988.

  13. Validation of the Danish 7-day pre-coded food diary among adults: energy intake v. energy expenditure and recording length

    DEFF Research Database (Denmark)

    Biltoft-Jensen, Anja Pia; Matthiessen, Jeppe; Rasmussen, Lone Banke

    2009-01-01

    Under-reporting of energy intake (EI) is a well-known problem when measuring dietary intake in free-living populations. The present study aimed at quantifying misreporting by comparing EI estimated from the Danish pre-coded food diary against energy expenditure (EE) measured with a validated...... position-and-motion instrument (ActiReg®). Further, the influence of recording length on EI:BMR, percentage consumers, the number of meal occasions and recorded food items per meal was examined. A total of 138 Danish volunteers aged 20–59 years wore the ActiReg® and recorded their food intake for 7...... for EI and EE were − 6·29 and 3·09 MJ/d. Of the participants, 73 % were classified as acceptable reporters, 26 % as under-reporters and 1 % as over-reporters. EI:BMR was significantly lower on 1–3 consecutive recording days compared with 4–7 recording days (P food...

  14. Imprisonment length and post-prison employment prospects

    NARCIS (Netherlands)

    Ramakers, Anke; Apel, Robert; Nieuwbeerta, Paul; Dirkzwager, Anja; Van Wilsem, Johan

    2014-01-01

    This study considers the relationship between imprisonment length and employment outcomes. The data are a unique prospective, longitudinal study of Dutch pretrial detainees (N = 702). All subjects thus experience prison confinement of varying lengths, although the durations are relatively short

  15. Does length of common limb influence remission of diabetes? Short-term results

    Directory of Open Access Journals (Sweden)

    Ramraj V Nagendra Gupta

    2016-01-01

    Full Text Available Background: Despite strict patient selection criteria, diabetes remission is not seen in all patients after gastric bypass. Can length of the common limb influence diabetes remission? Aim: To find if any correlation exists between the length of the common limb and remission of diabetes. Study Design: Prospective study. Materials and Methods: Twenty-five consecutive patients with Type II diabetes mellitus and a fasting C-peptide >1 ng/ml who underwent laparoscopic Roux-en-y gastric bypass were included. All patients had standard limb lengths and length of the common limb was measured in all patients. Patients were followed up and glycated haemoglobin (HbA1c was repeated at 6 months postoperatively. Pre- and postoperative HbA1c were then correlated with the lengths of common limb to look for any relation. Statistical Analysis: Descriptive and inferential statistical analysis, analysis of variance (ANOVA. Results: Of the 25 patients, 15 were females and 10 were males. The mean age was 44.16 years and the mean body mass index (BMI was 43.96 kg/m 2 . Preoperative HbA1c varied from 5.8 to 12.3%. Length of the common limb varied from 210 to 790 cm (mean 470.4 cm. HbA1c at 6 months ranged from 4.8 to 7.7% (mean 5.81%. On comparison of preoperative and 6 months postoperative HbA1c and correlating with the length of common limb, we found that patients with a common limb of length 600 cm length (P = 0.004. Conclusion: A shorter common limb does appear to have better chances of resolution of Type II diabetes mellitus in our study, thus paving the way for further studies.

  16. The effect of self-reported habitual sleep quality and sleep length on autobiographical memory.

    Science.gov (United States)

    Murre, Jaap M J; Kristo, Gert; Janssen, Steve M J

    2014-01-01

    A large number of studies have recently shown effects of sleep on memory consolidation. In this study the effects of the sleep quality and sleep length on the retention of autobiographical memories are examined, using an Internet-based diary technique (Kristo, Janssen, & Murre, 2009). Each of over 600 participants recorded one recent personal event and was contacted after a retention interval that ranged from 2 to 46 days. Recall of the content, time, and details of the event were scored and related to sleep quality and sleep length as measured with the Pittsburgh Sleep Quality Index. Hierarchical regression analyses indicated that poor sleep quality, but not short sleep length, was associated with significantly lower recall at the longer retention periods (30-46 days), but not at the shorter ones (2-15 days), although the difference in recall between good and poor sleepers was small.

  17. Length-weight relationships for fishes off the southwestern coast of ...

    African Journals Online (AJOL)

    Length-weight relationships are presented for 24 fish species representing 12 families captured monthly from February 2009 to March 2010, off the southwestern coast of Taiwan. 12 of these species are documented in fishbase, but no length-weight relationships were available. One record of maximum length was recorded.

  18. Effects of fiber length on mechanical properties and fracture behavior of short carbon fiber reinforced geopolymer matrix composites

    International Nuclear Information System (INIS)

    Lin Tiesong; Jia Dechang; He Peigang; Wang Meirong; Liang Defu

    2008-01-01

    A kind of sheet-like carbon fiber preform was developed using short fibers (2, 7 and 12 mm, respectively) as starting materials and used to strengthen a geopolymer. Mechanical properties, fracture behavior, microstructure and toughening mechanisms of the as-prepared composites were investigated by three-point bending test, optical microscope and scanning electron microscopy. The results show that the short carbon fibers disperse uniformly in geopolymer matrix. The C f /geopolymer composites exhibit apparently improved mechanical properties and an obvious noncatastrophic failure behavior. The composite reinforced by the carbon fibers of 7 mm in length shows a maximum flexural strength as well as the highest work of facture, which are nearly 5 times and more than 2 orders higher than that of the geopolymer matrix, respectively. The predominant strengthening and toughening mechanisms are attributed to the apparent fiber bridging and pulling-out effect based on the weak fiber/matrix interface as well as the sheet-like carbon fiber preform

  19. Evaluation of scaling invariance embedded in short time series.

    Directory of Open Access Journals (Sweden)

    Xue Pan

    Full Text Available Scaling invariance of time series has been making great contributions in diverse research fields. But how to evaluate scaling exponent from a real-world series is still an open problem. Finite length of time series may induce unacceptable fluctuation and bias to statistical quantities and consequent invalidation of currently used standard methods. In this paper a new concept called correlation-dependent balanced estimation of diffusion entropy is developed to evaluate scale-invariance in very short time series with length ~10(2. Calculations with specified Hurst exponent values of 0.2,0.3,...,0.9 show that by using the standard central moving average de-trending procedure this method can evaluate the scaling exponents for short time series with ignorable bias (≤0.03 and sharp confidential interval (standard deviation ≤0.05. Considering the stride series from ten volunteers along an approximate oval path of a specified length, we observe that though the averages and deviations of scaling exponents are close, their evolutionary behaviors display rich patterns. It has potential use in analyzing physiological signals, detecting early warning signals, and so on. As an emphasis, the our core contribution is that by means of the proposed method one can estimate precisely shannon entropy from limited records.

  20. Evaluation of scaling invariance embedded in short time series.

    Science.gov (United States)

    Pan, Xue; Hou, Lei; Stephen, Mutua; Yang, Huijie; Zhu, Chenping

    2014-01-01

    Scaling invariance of time series has been making great contributions in diverse research fields. But how to evaluate scaling exponent from a real-world series is still an open problem. Finite length of time series may induce unacceptable fluctuation and bias to statistical quantities and consequent invalidation of currently used standard methods. In this paper a new concept called correlation-dependent balanced estimation of diffusion entropy is developed to evaluate scale-invariance in very short time series with length ~10(2). Calculations with specified Hurst exponent values of 0.2,0.3,...,0.9 show that by using the standard central moving average de-trending procedure this method can evaluate the scaling exponents for short time series with ignorable bias (≤0.03) and sharp confidential interval (standard deviation ≤0.05). Considering the stride series from ten volunteers along an approximate oval path of a specified length, we observe that though the averages and deviations of scaling exponents are close, their evolutionary behaviors display rich patterns. It has potential use in analyzing physiological signals, detecting early warning signals, and so on. As an emphasis, the our core contribution is that by means of the proposed method one can estimate precisely shannon entropy from limited records.

  1. Evidence for a new geomagnetic reversal from lava flows in Idaho: discussion of short polarity reversals in the Brunhes and late Matuyama Polarity Chrons

    Science.gov (United States)

    Champion, D.E.; Lanphere, M.A.; Kuntz, M.A.

    1988-01-01

    K-Ar ages and paleomagnetic data for basalt samples from a new core hole (site E) at the Idaho National Engineering Laboratory (INEL) indicate that the age of the reversed polarity event recorded in Snake River Plain lavas is older than 465 ?? 50 ka (1000 years before present) reported previously by Champion et al. (1981). A review of data documenting short reversal records from volcanic and sedimentary rocks shows that there is evidence for eight polarity subchrons in the Brunhes and two besides the Jaramillo in the late Matuyama. These 10 short subchrons begin to indicate the many short events that Cox (1968) hypothesized must exist if polarity interval lengths have a Poisson distribution. The mean sustained polarity interval length since late Matuyama Chron time is 90 000 years. The similarity of this number with the 105-year period of the Earth's orbital eccentricity suggests anew that linkage between geomagnetic, paleoclimatic, and possible underlying Earth orbital parameters should be evaluated. -from Authors

  2. Comparison of axial length, anterior chamber depth and intraocular lens power between IOLMaster and ultrasound in normal, long and short eyes.

    Science.gov (United States)

    Dong, Jing; Zhang, Yaqin; Zhang, Haining; Jia, Zhijie; Zhang, Suhua; Wang, Xiaogang

    2018-01-01

    To compare the axial length (AL), anterior chamber depth (ACD) and intraocular lens power (IOLP) of IOLMaster and Ultrasound in normal, long and short eyes. Seventy-four normal eyes (≥ 22 mm and ≤ 25 mm), 74 long eyes (> 25 mm) and 78 short eyes (devices in the order of IOLMaster followed by Ultrasound. The IOLP were calculated using a free online LADAS IOL formula calculator. The difference in AL and IOLP between IOLMaster and Ultrasound was statistically significant when all three groups were combined. The difference in ACD between IOLMaster and Ultrasound was statistically significant in the normal group (Peye group (Peye group (P = 0.465). For the IOLP difference between IOLMaster and Ultrasound in the normal group, the percentage of IOLP differences eye group, they were 90.5%, 5.4%, 4.1% and 0%, respectively. For the short eye group, they were 61.5%, 23.1%, 10.3%, and 5.1%, respectively. IOLMaster and Ultrasound have statistically significant differences in AL measurements and IOLP (using LADAS formula) for normal, long eye and short eye. The two instruments agree regarding ACD measurements for the long eye group, but differ for the normal and short eye groups. Moreover, the high percentage of IOLP differences greater than |0.5|D in the short eye group is noteworthy.

  3. Does neighborhood size really cause the word length effect?

    Science.gov (United States)

    Guitard, Dominic; Saint-Aubin, Jean; Tehan, Gerald; Tolan, Anne

    2018-02-01

    In short-term serial recall, it is well-known that short words are remembered better than long words. This word length effect has been the cornerstone of the working memory model and a benchmark effect that all models of immediate memory should account for. Currently, there is no consensus as to what determines the word length effect. Jalbert and colleagues (Jalbert, Neath, Bireta, & Surprenant, 2011a; Jalbert, Neath, & Surprenant, 2011b) suggested that neighborhood size is one causal factor. In six experiments we systematically examined their suggestion. In Experiment 1, with an immediate serial recall task, multiple word lengths, and a large pool of words controlled for neighborhood size, the typical word length effect was present. In Experiments 2 and 3, with an order reconstruction task and words with either many or few neighbors, we observed the typical word length effect. In Experiment 4 we tested the hypothesis that the previous abolition of the word length effect when neighborhood size was controlled was due to a confounded factor: frequency of orthographic structure. As predicted, we reversed the word length effect when using short words with less frequent orthographic structures than the long words, as was done in both of Jalbert et al.'s studies. In Experiments 5 and 6, we again observed the typical word length effect, even if we controlled for neighborhood size and frequency of orthographic structure. Overall, the results were not consistent with the predictions of Jalbert et al. and clearly showed a large and reliable word length effect after controlling for neighborhood size.

  4. LENGTH-WEIGHT RELATIONSHIP AND CONDITION FACTOR OF ...

    African Journals Online (AJOL)

    Data Collection and Analysis. The measurements of length (cm), weight (g) and the condition factor of individual fish sampled were recorded. The relationship between length and weight of the fish was examined by simple linear regression using WINKS software. The variations in the length-weight represented by 'b' were.

  5. Minimal Length Scale Scenarios for Quantum Gravity.

    Science.gov (United States)

    Hossenfelder, Sabine

    2013-01-01

    We review the question of whether the fundamental laws of nature limit our ability to probe arbitrarily short distances. First, we examine what insights can be gained from thought experiments for probes of shortest distances, and summarize what can be learned from different approaches to a theory of quantum gravity. Then we discuss some models that have been developed to implement a minimal length scale in quantum mechanics and quantum field theory. These models have entered the literature as the generalized uncertainty principle or the modified dispersion relation, and have allowed the study of the effects of a minimal length scale in quantum mechanics, quantum electrodynamics, thermodynamics, black-hole physics and cosmology. Finally, we touch upon the question of ways to circumvent the manifestation of a minimal length scale in short-distance physics.

  6. Dependence of paracentric inversion rate on tract length

    DEFF Research Database (Denmark)

    York, Thomas L; Durrett, Rick; Nielsen, Rasmus

    2007-01-01

    BACKGROUND: We develop a Bayesian method based on MCMC for estimating the relative rates of pericentric and paracentric inversions from marker data from two species. The method also allows estimation of the distribution of inversion tract lengths. RESULTS: We apply the method to data from...... Drosophila melanogaster and D. yakuba. We find that pericentric inversions occur at a much lower rate compared to paracentric inversions. The average paracentric inversion tract length is approx. 4.8 Mb with small inversions being more frequent than large inversions.If the two breakpoints defining...... a paracentric inversion tract are uniformly and independently distributed over chromosome arms there will be more short tract-length inversions than long; we find an even greater preponderance of short tract lengths than this would predict. Thus there appears to be a correlation between the positions...

  7. Role of Fiber Length on Phagocytosis & Inflammatory Response

    Science.gov (United States)

    Turkevich, Leonid; Stark, Carahline; Champion, Julie

    2014-03-01

    Asbestos fibers have long been associated with lung cancer death. The inability of immune cells (e.g. macrophages) to effectively remove asbestos leads to chronic inflammation and disease. This study examines the role of fiber length on toxicity at the cellular level using model glass fibers. A major challenge is obtaining single diameter fibers but differing in length. Samples of 1 micron diameter fibers with different length distributions were prepared: short fibers (less than 15 microns) by aggressive crushing, and long fibers (longer than 15 microns) by successive sedimentation. Time-lapse video microscopy monitored the interaction of MH-S murine alveolar macrophages with the fibers: short fibers were easily internalized by the macrophages, but long fibers resisted internalization over many hours. Production of TNF- α (tumor necrosis factor alpha), a general inflammatory secreted cytokine, and Cox-2 (cyclo-oxygenase-2), an enzyme that produces radicals, each exhibited a dose-dependence that was greater for long than for short fibers. These results corroborate the importance of fiber length in both physical and biochemical cell response and support epidemiological observations of higher toxicity for longer fibers.

  8. Length, Lexicality, and Articulatory Suppression in Immediate Recall: Evidence against the Articulatory Loop

    Science.gov (United States)

    Romani, C.; McAlpine, S.; Olson, A.; Tsouknida, E.; Martin, R.

    2005-01-01

    Influential models of short-term memory have attributed the fact that short words are recalled better than longer words in serial recall (the length effect) to articulatory rehearsal. Crucial for this link is the finding that the length effect disappears under articulatory suppression. We show, instead, that, under suppression, the length effect…

  9. Telomere Length and the Cancer-Atherosclerosis Trade-Off.

    Directory of Open Access Journals (Sweden)

    Rivka C Stone

    2016-07-01

    Full Text Available Modern humans, the longest-living terrestrial mammals, display short telomeres and repressed telomerase activity in somatic tissues compared with most short-living small mammals. The dual trait of short telomeres and repressed telomerase might render humans relatively resistant to cancer compared with short-living small mammals. However, the trade-off for cancer resistance is ostensibly increased age-related degenerative diseases, principally in the form of atherosclerosis. In this communication, we discuss (a the genetics of human telomere length, a highly heritable complex trait that is influenced by genetic ancestry, sex, and paternal age at conception, (b how cancer might have played a role in the evolution of telomere biology across mammals, (c evidence that in modern humans telomere length is a determinant (rather than only a biomarker of cancer and atherosclerosis, and (d the potential influence of relatively recent evolutionary forces in fashioning the variation in telomere length across and within populations, and their likely lasting impact on major diseases in humans. Finally, we propose venues for future research on human telomere genetics in the context of its potential role in shaping the modern human lifespan.

  10. Short telomere length is associated with NOTCH1/SF3B1/TP53 aberrations and poor outcome in newly diagnosed chronic lymphocytic leukemia patients

    DEFF Research Database (Denmark)

    Mansouri, Larry; Grabowski, Pawel; Degerman, Sofie

    2013-01-01

    Most previous studies on telomere length (TL) in chronic lymphocytic leukemia (CLL) are based on referral cohorts including a high proportion of aggressive cases. Here, the impact of TL was analyzed in a population-based cohort of newly diagnosed CLL (n = 265) and in relation to other prognostic ...... markers. Short telomeres were particularly associated with high-risk genetic markers, such as NOTCH1, SF3B1, or TP53 aberrations, and predicted a short time to treatment (TTT) and overall survival (OS) (both P...

  11. Short-term coral bleaching is not recorded by skeletal boron isotopes.

    Science.gov (United States)

    Schoepf, Verena; McCulloch, Malcolm T; Warner, Mark E; Levas, Stephen J; Matsui, Yohei; Aschaffenburg, Matthew D; Grottoli, Andréa G

    2014-01-01

    Coral skeletal boron isotopes have been established as a proxy for seawater pH, yet it remains unclear if and how this proxy is affected by seawater temperature. Specifically, it has never been directly tested whether coral bleaching caused by high water temperatures influences coral boron isotopes. Here we report the results from a controlled bleaching experiment conducted on the Caribbean corals Porites divaricata, Porites astreoides, and Orbicella faveolata. Stable boron (δ11B), carbon (δ13C), oxygen (δ18O) isotopes, Sr/Ca, Mg/Ca, U/Ca, and Ba/Ca ratios, as well as chlorophyll a concentrations and calcification rates were measured on coral skeletal material corresponding to the period during and immediately after the elevated temperature treatment and again after 6 weeks of recovery on the reef. We show that under these conditions, coral bleaching did not affect the boron isotopic signature in any coral species tested, despite significant changes in coral physiology. This contradicts published findings from coral cores, where significant decreases in boron isotopes were interpreted as corresponding to times of known mass bleaching events. In contrast, δ13C and δ18O exhibited major enrichment corresponding to decreases in calcification rates associated with bleaching. Sr/Ca of bleached corals did not consistently record the 1.2°C difference in seawater temperature during the bleaching treatment, or alternatively show a consistent increase due to impaired photosynthesis and calcification. Mg/Ca, U/Ca, and Ba/Ca were affected by coral bleaching in some of the coral species, but the observed patterns could not be satisfactorily explained by temperature dependence or changes in coral physiology. This demonstrates that coral boron isotopes do not record short-term bleaching events, and therefore cannot be used as a proxy for past bleaching events. The robustness of coral boron isotopes to changes in coral physiology, however, suggests that reconstruction of

  12. Preventing Preterm Birth with Progesterone in Women with a Short Cervical Length from a Low-Risk Population: A Multicenter Double-Blind Placebo-Controlled Randomized Trial

    NARCIS (Netherlands)

    van Os, M.A.; van der Ven, A.J.; Kleinrouweler, C.E.; Schuit, E.; Kazemier, B.M.; Verhoeven, C.J.M.; de Miranda, E.; van Wassenaer-Leemhuis, A.G.; Sikkema, J.M.; Woiski, M.D.; Bossuyt, P.M.; Pajkrt, E.; de Groot, C.J.M.; Mol, B.W.J.; Haak, M.C.

    2015-01-01

    Objective The objective of this study was to evaluate the effectiveness of vaginal progesterone in reducing adverse neonatal outcome due to preterm birth (PTB) in low-risk pregnant women with a short cervical length (CL). Study Design Women with a singleton pregnancy without a history of PTB

  13. Minimal Length Scale Scenarios for Quantum Gravity

    Directory of Open Access Journals (Sweden)

    Sabine Hossenfelder

    2013-01-01

    Full Text Available We review the question of whether the fundamental laws of nature limit our ability to probe arbitrarily short distances. First, we examine what insights can be gained from thought experiments for probes of shortest distances, and summarize what can be learned from different approaches to a theory of quantum gravity. Then we discuss some models that have been developed to implement a minimal length scale in quantum mechanics and quantum field theory. These models have entered the literature as the generalized uncertainty principle or the modified dispersion relation, and have allowed the study of the effects of a minimal length scale in quantum mechanics, quantum electrodynamics, thermodynamics, black-hole physics and cosmology. Finally, we touch upon the question of ways to circumvent the manifestation of a minimal length scale in short-distance physics.

  14. Length-weight and length-length relationships of common carp (Cyprinus carpio L.) in the middle and southern Iraq provinces

    Science.gov (United States)

    Al-jebory, Taymaa A.; Das, Simon K.; Usup, Gires; Bakar, Y.; Al-saadi, Ali H.

    2018-04-01

    In this study, length-weight and length-length relationships of common carp (Cyprinus carpio L.) in the middle and southern Iraq provinces were determined. Fish specimens were procured from seven provinces from July to December, 2015. A negative and positive allometric growth pattern was obtained, where the total length (TL) ranged from 25.60 cm to 33.53 cm, and body weight (BW) ranged from 700 g to 1423 g. Meanwhile, the lowest of 1.03 and highest of 3.54 in "b" value was recorded in group F and group C, respectively. Therefore, Fulton condition factor (K) range from 2.57 to 4.94. While, relative condition factor (Kn) was in the ranged of 0.95 to 1.01. A linear relationship between total length (TL) and standard length (SL) among the provinces for fish groups was obtained. The variances in "b" value ranged from 0.10 to 0.93 with correlation coefficient (r2) of 0.02 to 0.97. This research could be used as a guide to study the ecology and biology of common Carp (Cyprinus carpio L.) in the middle and southern Iraq provinces.

  15. History-dependence of muscle slack length following contraction and stretch in the human vastus lateralis.

    Science.gov (United States)

    Stubbs, Peter W; Walsh, Lee D; D'Souza, Arkiev; Héroux, Martin E; Bolsterlee, Bart; Gandevia, Simon C; Herbert, Robert D

    2018-06-01

    In reduced muscle preparations, the slack length and passive stiffness of muscle fibres have been shown to be influenced by previous muscle contraction or stretch. In human muscles, such behaviours have been inferred from measures of muscle force, joint stiffness and reflex magnitudes and latencies. Using ultrasound imaging, we directly observed that isometric contraction of the vastus lateralis muscle at short lengths reduces the slack lengths of the muscle-tendon unit and muscle fascicles. The effect is apparent 60 s after the contraction. These observations imply that muscle contraction at short lengths causes the formation of bonds which reduce the effective length of structures that generate passive tension in muscles. In reduced muscle preparations, stretch and muscle contraction change the properties of relaxed muscle fibres. In humans, effects of stretch and contraction on properties of relaxed muscles have been inferred from measurements of time taken to develop force, joint stiffness and reflex latencies. The current study used ultrasound imaging to directly observe the effects of stretch and contraction on muscle-tendon slack length and fascicle slack length of the human vastus lateralis muscle in vivo. The muscle was conditioned by (a) strong isometric contractions at long muscle-tendon lengths, (b) strong isometric contractions at short muscle-tendon lengths, (c) weak isometric contractions at long muscle-tendon lengths and (d) slow stretches. One minute after conditioning, ultrasound images were acquired from the relaxed muscle as it was slowly lengthened through its physiological range. The ultrasound image sequences were used to identify muscle-tendon slack angles and fascicle slack lengths. Contraction at short muscle-tendon lengths caused a mean 13.5 degree (95% CI 11.8-15.0 degree) shift in the muscle-tendon slack angle towards shorter muscle-tendon lengths, and a mean 5 mm (95% CI 2-8 mm) reduction in fascicle slack length, compared to the

  16. Effective length of short Fabry-Perot cavity formed by uniform fiber Bragg gratings.

    Science.gov (United States)

    Barmenkov, Yuri O; Zalvidea, Dobryna; Torres-Peiró, Salvador; Cruz, Jose L; Andrés, Miguel V

    2006-07-10

    In this paper, we describe the properties of Fabry-Perot fiber cavity formed by two fiber Bragg gratings in terms of the grating effective length. We show that the grating effective length is determined by the group delay of the grating, which depends on its diffraction efficiency and physical length. We present a simple analytical formula for calculation of the effective length of the uniform fiber Bragg grating and the frequency separation between consecutive resonances of a Fabry-Perot cavity. Experimental results on the cavity transmission spectra for different values of the gratings' reflectivity support the presented theory.

  17. Combination of short-length TiO_2 nanorod arrays and compact PbS quantum-dot thin films for efficient solid-state quantum-dot-sensitized solar cells

    International Nuclear Information System (INIS)

    Zhang, Zhengguo; Shi, Chengwu; Chen, Junjun; Xiao, Guannan; Li, Long

    2017-01-01

    Graphical abstract: The TiO_2 nanorod array with the length of 600 nm, the diameter of 20 nm, the areal density of 500 μm"−"2 was successfully prepared. The compact PbS quantum-dot thin film was firstly obtained on the TiO_2 nanorod array by spin-coating-assisted successive ionic layer absorption and reaction with using 1,2-ethanedithiol. The photoelectric conversion efficiency (PCE) of the compact PbS quantum-dot thin film sensitized solar cells achieved 4.10% using spiro-OMeTAD as a hole transporting layer, while the PCE of the PbS quantum-dot sensitized solar cells was only 0.54%. - Highlights: • Preparation of TiO_2 nanorod arrays with the length of 600 nm, diameter of 20 nm. • The compact PbS QD thin film and short-length TiO_2 nanorod array were combined. • EDT addition improved PbS nanoparticle coverage and photovoltaic performance. • The compact PbS QD thin film sensitized solar cell achieved the PCE of 4.10%. - Abstract: Considering the balance of the hole diffusion length and the loading quantity of quantum-dots, the rutile TiO_2 nanorod array with the length of 600 nm, the diameter of 20 nm, and the areal density of 500 μm"−"2 is successfully prepared by the hydrothermal method using the aqueous grown solution of 38 mM titanium isopropoxide and 6 M hydrochloric acid at 170 °C for 105 min. The compact PbS quantum-dot thin film on the TiO_2 nanorod array is firstly obtained by the spin-coating-assisted successive ionic layer absorption and reaction with using 1,2-ethanedithiol (EDT). The result reveals that the strong interaction between lead and EDT is very important to control the crystallite size of PbS quantum-dots and obtain the compact PbS quantum-dot thin film on the TiO_2 nanorod array. The all solid-state sensitized solar cell with the combination of the short-length, high-density TiO_2 nanorod array and the compact PbS quantum-dot thin film achieves the photoelectric conversion efficiency of 4.10%, along with an open

  18. Postsacral vertebral morphology in relation to tail length among primates and other mammals.

    Science.gov (United States)

    Russo, Gabrielle A

    2015-02-01

    Tail reduction/loss independently evolved in a number of mammalian lineages, including hominoid primates. One prerequisite to appropriately contextualizing its occurrence and understanding its significance is the ability to track evolutionary changes in tail length throughout the fossil record. However, to date, the bony correlates of tail length variation among living taxa have not been comprehensively examined. This study quantifies postsacral vertebral morphology among living primates and other mammals known to differ in relative tail length (RTL). Linear and angular measurements with known biomechanical significance were collected on the first, mid-, and transition proximal postsacral vertebrae, and their relationship with RTL was assessed using phylogenetic generalized least-squares regression methods. Compared to shorter-tailed primates, longer-tailed primates possess a greater number of postsacral vertebral features associated with increased proximal tail flexibility (e.g., craniocaudally longer vertebral bodies), increased intervertebral body joint range of motion (e.g., more circularly shaped cranial articular surfaces), and increased leverage of tail musculature (e.g., longer spinous processes). These observations are corroborated by the comparative mammalian sample, which shows that distantly related short-tailed (e.g., Phascolarctos, Lynx) and long-tailed (e.g., Dendrolagus, Acinonyx) nonprimate mammals morphologically converge with short-tailed (e.g., Macaca tonkeana) and long-tailed (e.g., Macaca fascicularis) primates, respectively. Multivariate models demonstrate that the variables examined account for 70% (all mammals) to 94% (only primates) of the variance in RTL. Results of this study may be used to infer the tail lengths of extinct primates and other mammals, thereby improving our understanding about the evolution of tail reduction/loss. © 2014 Wiley Periodicals, Inc.

  19. Superconductivity, charge orderings, magnetism, and their phase separations in the ground state of lattice models of superconductor with very short coherence length

    OpenAIRE

    Kapcia, Konrad Jerzy

    2015-01-01

    This is an author-created, un-copyedited version of an article accepted for publication in Journal of Superconductivity and Novel Magnetism. We present the ground state results for lattice models of superconductor (SC) with extremely short coherence length, which also involve the interplay with charge (CO) and (anti-)ferromagnetic orderings. Our preliminary results at zero-temperature (derived by means of the variational approach which treats the on-site interaction term exactly and the in...

  20. The effect of word length and other sublexical, lexical, and semantic variables on developmental reading deficits.

    Science.gov (United States)

    De Luca, Maria; Barca, Laura; Burani, Cristina; Zoccolotti, Pierluigi

    2008-12-01

    To examine the effect of word length and several sublexical, and lexico-semantic variables on the reading of Italian children with a developmental reading deficit. Previous studies indicated the role of word length in transparent orthographies. However, several factors that may interact with word length were not controlled for. Seventeen impaired and 34 skilled sixth-grade readers were presented words of different lengths, matched for initial phoneme, bigram frequency, word frequency, age of acquisition, and imageability. Participants were asked to read aloud, as quickly and as accurately as possible. Reaction times at the onset of pronunciation and mispronunciations were recorded. Impaired readers' reaction times indicated a marked effect of word length; in skilled readers, there was no length effect for short words but, rather, a monotonic increase from 6-letter words on. Regression analyses confirmed the role of word length and indicated the influence of word frequency (similar in impaired and skilled readers). No other variables predicted reading latencies. Word length differentially influenced word recognition in impaired versus skilled readers, irrespective of the action of (potentially interfering) sublexical, lexical, and semantic variables. It is proposed that the locus of the length effect is at a perceptual level of analysis. The independent influence of word frequency on the reading performance of both groups of participants indicates the sparing of lexical activation in impaired readers.

  1. Intraflagellar transport particle size scales inversely with flagellar length: revisiting the balance-point length control model.

    Science.gov (United States)

    Engel, Benjamin D; Ludington, William B; Marshall, Wallace F

    2009-10-05

    The assembly and maintenance of eukaryotic flagella are regulated by intraflagellar transport (IFT), the bidirectional traffic of IFT particles (recently renamed IFT trains) within the flagellum. We previously proposed the balance-point length control model, which predicted that the frequency of train transport should decrease as a function of flagellar length, thus modulating the length-dependent flagellar assembly rate. However, this model was challenged by the differential interference contrast microscopy observation that IFT frequency is length independent. Using total internal reflection fluorescence microscopy to quantify protein traffic during the regeneration of Chlamydomonas reinhardtii flagella, we determined that anterograde IFT trains in short flagella are composed of more kinesin-associated protein and IFT27 proteins than trains in long flagella. This length-dependent remodeling of train size is consistent with the kinetics of flagellar regeneration and supports a revised balance-point model of flagellar length control in which the size of anterograde IFT trains tunes the rate of flagellar assembly.

  2. Association of Donor and Recipient Telomere Length with Clinical Outcomes following Lung Transplantation.

    Science.gov (United States)

    Courtwright, Andrew M; Fried, Sabrina; Villalba, Julian A; Moniodis, Anna; Guleria, Indira; Wood, Isabelle; Milford, Edgar; Mallidi, Hari H; Hunninghake, Gary M; Raby, Benjamin A; Agarwal, Suneet; Camp, Philip C; Rosas, Ivan O; Goldberg, Hilary J; El-Chemaly, Souheil

    2016-01-01

    Patients with short telomere syndromes and pulmonary fibrosis have increased complications after lung transplant. However, the more general impact of donor and recipient telomere length in lung transplant has not been well characterized. This was an observational cohort study of patients who received lung transplant at a single center between January 1st 2012 and January 31st 2015. Relative donor lymphocyte telomere length was measured and classified into long (third tertile) and short (other tertiles). Relative recipient lung telomere length was measured and classified into short (first tertile) and long (other tertiles). Outcome data included survival, need for modification of immunosuppression, liver or kidney injury, cytomegalovirus reactivation, and acute rejection. Recipient lung tissue telomere lengths were measured for 54 of the 79 patients (68.3%) who underwent transplant during the study period. Donor lymphocyte telomeres were measured for 45 (83.3%) of these recipients. Neither long donor telomere length (hazard ratio [HR] = 0.58, 95% confidence interval [CI], 0.12-2.85, p = 0.50) nor short recipient telomere length (HR = 1.01, 95% CI = 0.50-2.05, p = 0.96) were associated with adjusted survival following lung transplant. Recipients with short telomeres were less likely to have acute cellular rejection (23.5% vs. 58.8%, p = 0.02) but were not more likely to have other organ dysfunction. In this small cohort, neither long donor lymphocyte telomeres nor short recipient lung tissue telomeres were associated with adjusted survival after lung transplantation. Larger studies are needed to confirm these findings.

  3. Short Hospital Stay after Laparoscopic Colorectal Surgery without Fast Track

    DEFF Research Database (Denmark)

    Burgdorf, Stefan K; Rosenberg, Jacob

    2012-01-01

    Purpose. Short hospital stay and equal or reduced complication rates have been demonstrated after fast track open colonic surgery. However, fast track principles of perioperative care can be difficult to implement and often require increased nursing staff because of more concentrated nursing tasks...... care, that is, without implementing fast track principles, on length of stay after colorectal resection for cancer. Methods. Records of all patients operated for colorectal cancer from November 2004 to December 2008 in our department were reviewed. No specific patients were selected for laparoscopic...... in our department resulted in shorter hospital stay without using fast track principles for peri- and postoperative care in patients not receiving a stoma during the operation. Consequently, we aimed to reduce hospitalisation without increasing cost in nursing staff per hospital bed. Length of stay...

  4. Quantum discord length is enhanced while entanglement length is not by introducing disorder in a spin chain.

    Science.gov (United States)

    Sadhukhan, Debasis; Roy, Sudipto Singha; Rakshit, Debraj; Prabhu, R; Sen De, Aditi; Sen, Ujjwal

    2016-01-01

    Classical correlation functions of ground states typically decay exponentially and polynomially, respectively, for gapped and gapless short-range quantum spin systems. In such systems, entanglement decays exponentially even at the quantum critical points. However, quantum discord, an information-theoretic quantum correlation measure, survives long lattice distances. We investigate the effects of quenched disorder on quantum correlation lengths of quenched averaged entanglement and quantum discord, in the anisotropic XY and XYZ spin glass and random field chains. We find that there is virtually neither reduction nor enhancement in entanglement length while quantum discord length increases significantly with the introduction of the quenched disorder.

  5. Perception of Vowel Length by Japanese- and English-Learning Infants

    Science.gov (United States)

    Mugitani, Ryoko; Pons, Ferran; Fais, Laurel; Dietrich, Christiane; Werker, Janet F.; Amano, Shigeaki

    2009-01-01

    This study investigated vowel length discrimination in infants from 2 language backgrounds, Japanese and English, in which vowel length is either phonemic or nonphonemic. Experiment 1 revealed that English 18-month-olds discriminate short and long vowels although vowel length is not phonemically contrastive in English. Experiments 2 and 3 revealed…

  6. Impedance of finite length resistive cylinder

    Directory of Open Access Journals (Sweden)

    S. Krinsky

    2004-11-01

    Full Text Available We determine the impedance of a cylindrical metal tube (resistor of radius a, length g, and conductivity σ attached at each end to perfect conductors of semi-infinite length. Our main interest is in the asymptotic behavior of the impedance at high frequency (k≫1/a. In the equilibrium regime, ka^{2}≪g, the impedance per unit length is accurately described by the well-known result for an infinite length tube with conductivity σ. In the transient regime, ka^{2}≫g, where the contribution of transition radiation arising from the discontinuity in conductivity is important, we derive an analytic expression for the impedance and compute the short-range wakefield. The analytic results are shown to agree with numerical evaluation of the impedance.

  7. Combination of short-length TiO{sub 2} nanorod arrays and compact PbS quantum-dot thin films for efficient solid-state quantum-dot-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Zhengguo [School of Chemistry and Chemical Engineering, Hefei University of Technology, Hefei 230009 (China); School of Chemistry and Chemical Engineering, Beifang University of Nationalities, Yinchuan 750021 (China); Shi, Chengwu, E-mail: shicw506@foxmail.com [School of Chemistry and Chemical Engineering, Hefei University of Technology, Hefei 230009 (China); Chen, Junjun; Xiao, Guannan; Li, Long [School of Chemistry and Chemical Engineering, Hefei University of Technology, Hefei 230009 (China)

    2017-07-15

    Graphical abstract: The TiO{sub 2} nanorod array with the length of 600 nm, the diameter of 20 nm, the areal density of 500 μm{sup −2} was successfully prepared. The compact PbS quantum-dot thin film was firstly obtained on the TiO{sub 2} nanorod array by spin-coating-assisted successive ionic layer absorption and reaction with using 1,2-ethanedithiol. The photoelectric conversion efficiency (PCE) of the compact PbS quantum-dot thin film sensitized solar cells achieved 4.10% using spiro-OMeTAD as a hole transporting layer, while the PCE of the PbS quantum-dot sensitized solar cells was only 0.54%. - Highlights: • Preparation of TiO{sub 2} nanorod arrays with the length of 600 nm, diameter of 20 nm. • The compact PbS QD thin film and short-length TiO{sub 2} nanorod array were combined. • EDT addition improved PbS nanoparticle coverage and photovoltaic performance. • The compact PbS QD thin film sensitized solar cell achieved the PCE of 4.10%. - Abstract: Considering the balance of the hole diffusion length and the loading quantity of quantum-dots, the rutile TiO{sub 2} nanorod array with the length of 600 nm, the diameter of 20 nm, and the areal density of 500 μm{sup −2} is successfully prepared by the hydrothermal method using the aqueous grown solution of 38 mM titanium isopropoxide and 6 M hydrochloric acid at 170 °C for 105 min. The compact PbS quantum-dot thin film on the TiO{sub 2} nanorod array is firstly obtained by the spin-coating-assisted successive ionic layer absorption and reaction with using 1,2-ethanedithiol (EDT). The result reveals that the strong interaction between lead and EDT is very important to control the crystallite size of PbS quantum-dots and obtain the compact PbS quantum-dot thin film on the TiO{sub 2} nanorod array. The all solid-state sensitized solar cell with the combination of the short-length, high-density TiO{sub 2} nanorod array and the compact PbS quantum-dot thin film achieves the photoelectric conversion

  8. Short-term memory functions of the human fetus recorded with magnetoencephalography.

    Science.gov (United States)

    Huotilainen, Minna; Kujala, Anu; Hotakainen, Merja; Parkkonen, Lauri; Taulu, Samu; Simola, Juha; Nenonen, Jukka; Karjalainen, Matti; Näätänen, Risto

    2005-01-19

    Studies in fetuses and in prematurely born infants show that auditory discriminative skills are present prior to birth. The magnetic fields generated by the fetal brain activity pass the maternal tissues and, despite their weakness, can be detected externally using MEG. Recent studies on the auditory evoked magnetic responses show that the fetal brain responds to sound onset. In contrast, higher-level auditory skills, such as those involving discriminative and memory functions, were not so far studied in fetuses with MEG. Here we show that fetal responses related to discriminating sounds can be recorded, implicating that the auditory change-detection system is functional. These results open new views to developmental neuroscience by enabling one to determine the sensory capabilities as well as the extent and accuracy of the short-term memory system of the fetus, and, further, to follow the development of these crucial processes.

  9. Concreteness effects in short-term memory: a test of the item-order hypothesis.

    Science.gov (United States)

    Roche, Jaclynn; Tolan, G Anne; Tehan, Gerald

    2011-12-01

    The following experiments explore word length and concreteness effects in short-term memory within an item-order processing framework. This framework asserts order memory is better for those items that are relatively easy to process at the item level. However, words that are difficult to process benefit at the item level for increased attention/resources being applied. The prediction of the model is that differential item and order processing can be detected in episodic tasks that differ in the degree to which item or order memory are required by the task. The item-order account has been applied to the word length effect such that there is a short word advantage in serial recall but a long word advantage in item recognition. The current experiment considered the possibility that concreteness effects might be explained within the same framework. In two experiments, word length (Experiment 1) and concreteness (Experiment 2) are examined using forward serial recall, backward serial recall, and item recognition. These results for word length replicate previous studies showing the dissociation in item and order tasks. The same was not true for the concreteness effect. In all three tasks concrete words were better remembered than abstract words. The concreteness effect cannot be explained in terms of an item-order trade off. PsycINFO Database Record (c) 2011 APA, all rights reserved.

  10. Telomere Length Reprogramming in Embryos and Stem Cells

    Directory of Open Access Journals (Sweden)

    Keri Kalmbach

    2014-01-01

    Full Text Available Telomeres protect and cap linear chromosome ends, yet these genomic buffers erode over an organism’s lifespan. Short telomeres have been associated with many age-related conditions in humans, and genetic mutations resulting in short telomeres in humans manifest as syndromes of precocious aging. In women, telomere length limits a fertilized egg’s capacity to develop into a healthy embryo. Thus, telomere length must be reset with each subsequent generation. Although telomerase is purportedly responsible for restoring telomere DNA, recent studies have elucidated the role of alternative telomeres lengthening mechanisms in the reprogramming of early embryos and stem cells, which we review here.

  11. Phonological short-term memory impairment and the word length effect in children with intellectual disabilities.

    Science.gov (United States)

    Poloczek, Sebastian; Büttner, Gerhard; Hasselhorn, Marcus

    2014-02-01

    There is mounting evidence that children and adolescents with intellectual disabilities (ID) of nonspecific aetiology perform poorer on phonological short-term memory tasks than children matched for mental age indicating a structural deficit in a process contributing to short-term recall of verbal material. One explanation is that children with ID of nonspecific aetiology do not activate subvocal rehearsal to refresh degrading memory traces. However, existing research concerning this explanation is inconclusive since studies focussing on the word length effect (WLE) as indicator of rehearsal have revealed inconsistent results for samples with ID and because in several existing studies, it is unclear whether the WLE was caused by rehearsal or merely appeared during output of the responses. We assumed that in children with ID only output delays produce a small WLE while in typically developing 6- to 8-year-olds rehearsal and output contribute to the WLE. From this assumption we derived several predictions that were tested in an experiment including 34 children with mild or borderline ID and 34 typically developing children matched for mental age (MA). As predicted, results revealed a small but significant WLE for children with ID that was significantly smaller than the WLE in the control group. Additionally, for children with ID, a WLE was not found for the first word of each trial but the effect emerged only in later serial positions. The findings corroborate the notion that in children with ID subvocal rehearsal does not develop in line with their mental age and provide a potential explanation for the inconsistent results on the WLE in children with ID. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Modeling Timbre Similarity of Short Music Clips.

    Science.gov (United States)

    Siedenburg, Kai; Müllensiefen, Daniel

    2017-01-01

    There is evidence from a number of recent studies that most listeners are able to extract information related to song identity, emotion, or genre from music excerpts with durations in the range of tenths of seconds. Because of these very short durations, timbre as a multifaceted auditory attribute appears as a plausible candidate for the type of features that listeners make use of when processing short music excerpts. However, the importance of timbre in listening tasks that involve short excerpts has not yet been demonstrated empirically. Hence, the goal of this study was to develop a method that allows to explore to what degree similarity judgments of short music clips can be modeled with low-level acoustic features related to timbre. We utilized the similarity data from two large samples of participants: Sample I was obtained via an online survey, used 16 clips of 400 ms length, and contained responses of 137,339 participants. Sample II was collected in a lab environment, used 16 clips of 800 ms length, and contained responses from 648 participants. Our model used two sets of audio features which included commonly used timbre descriptors and the well-known Mel-frequency cepstral coefficients as well as their temporal derivates. In order to predict pairwise similarities, the resulting distances between clips in terms of their audio features were used as predictor variables with partial least-squares regression. We found that a sparse selection of three to seven features from both descriptor sets-mainly encoding the coarse shape of the spectrum as well as spectrotemporal variability-best predicted similarities across the two sets of sounds. Notably, the inclusion of non-acoustic predictors of musical genre and record release date allowed much better generalization performance and explained up to 50% of shared variance ( R 2 ) between observations and model predictions. Overall, the results of this study empirically demonstrate that both acoustic features related

  13. Change in muscle fascicle length influences the recruitment and discharge rate of motor units during isometric contractions.

    Science.gov (United States)

    Pasquet, Benjamin; Carpentier, Alain; Duchateau, Jacques

    2005-11-01

    This study examines the effect of fascicle length change on motor-unit recruitment and discharge rate in the human tibialis anterior (TA) during isometric contractions of various intensities. The torque produced during dorsiflexion and the surface and intramuscular electromyograms (EMGs) from the TA were recorded in eight subjects. The behavior of the same motor unit (n = 59) was compared at two ankle joint angles (+10 and -10 degrees around the ankle neutral position). Muscle fascicle length of the TA was measured noninvasively using ultrasonography recordings. When the ankle angle was moved from 10 degrees plantarflexion to 10 degrees dorsiflexion, the torque produced during maximal voluntary contraction (MVC) was significantly reduced [35.2 +/- 3.3 vs. 44.3 +/- 4.2 (SD) Nm; P Motor units were activated at a lower recruitment threshold for short compared with long muscle fascicle length, either when expressed in absolute values (2.1 +/- 2.5 vs. 3.6 +/- 3.7 Nm; P motor-unit recruitment were observed at a given absolute or relative torque when muscle fascicles were shortened. However, the data indicate that increased rate coding was mainly present at low torque level (recruitment of additional motor units played a dominant role at higher torque level and decreased compliance (10-35% MVC). Taken together, the results suggest that the central command is modulated by the afferent proprioceptive information during submaximal contractions performed at different muscle fascicle lengths.

  14. Soliton scatterings by impurities in a short-length sine-Gordon chain

    International Nuclear Information System (INIS)

    Dikande, A.M.; Kofane, T.C.

    1995-07-01

    The scattering of soliton by impurities at the frontiers of a finite-length region of an infinite sine-Gordon chain is analyzed. The impurities consist of two isotopic inhomogeneities installed at the boundaries of the finite-length region. The soliton solution in the region is found in term of snoidal sine-Gordon soliton which properly takes into account the effects of the boundaries. By contrast, the soliton solutions in the neighboring sides of the region are obtained in terms of the so-called large-amplitude, localized kinks with limiting spatial extensions at x → ± ∞, which is equal ±π. Using the continuity of these soliton solutions at the frontiers as well as appropriate boundary conditions, it is shown that the soliton may be either i) reflected by the incident impurity; ii) trapped (with oscillating motions) between the two impurities (i.e. inside the infinite region); or iii) transmitted by the second impurity into the third, infinitely extended region. The threshold velocities for the reflection and transmission into different regions are found and shown to vary exponentially as a function of the length of the bounded region. The frequency of soliton oscillations between the impurities has also been calculated in some acceptable limit. (author). 28 refs, 1 fig

  15. Relation of Stump Length with Various Gait Parameters in Trans-tibial Amputee

    Directory of Open Access Journals (Sweden)

    Koyel Majumdar

    2008-07-01

    Full Text Available The purpose of this paper is evaluating the impact of stump length of unilateral below knee amputees (BKA on different gait parameters. Nine unilateral BKA were chosen and divided into three groups comprising patients with short, medium, and long stump length. Each of them underwent gait analysis test by Computer Dynography (CDG system to measure the gait parameters. It was found that the ground reaction force is higher in the patients with medium stump length whereas the velocity, step length both for the prosthetic and sound limb and cadence were high in longer stump length. Statistical analysis shows a significant difference (p<0.05 between the gait parameters of BKA with medium and longer stump length. The patients with longer stump length were more efficient than medium and short stump patients as they consumed comparatively lesser energy while walking with self-selected velocity and conventional (Solid ankle cushioned heel SACH foot.

  16. CEBAF Upgrade Bunch Length Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Mahmoud [Old Dominion Univ., Norfolk, VA (United States)

    2016-05-01

    Many accelerators use short electron bunches and measuring the bunch length is important for efficient operations. CEBAF needs a suitable bunch length because bunches that are too long will result in beam interruption to the halls due to excessive energy spread and beam loss. In this work, bunch length is measured by invasive and non-invasive techniques at different beam energies. Two new measurement techniques have been commissioned; a harmonic cavity showed good results compared to expectations from simulation, and a real time interferometer is commissioned and first checkouts were performed. Three other techniques were used for measurements and comparison purposes without modifying the old procedures. Two of them can be used when the beam is not compressed longitudinally while the other one, the synchrotron light monitor, can be used with compressed or uncompressed beam.

  17. Length and elasticity of side reins affect rein tension at trot.

    Science.gov (United States)

    Clayton, Hilary M; Larson, Britt; Kaiser, LeeAnn J; Lavagnino, Michael

    2011-06-01

    This study investigated the horse's contribution to tension in the reins. The experimental hypotheses were that tension in side reins (1) increases biphasically in each trot stride, (2) changes inversely with rein length, and (3) changes with elasticity of the reins. Eight riding horses trotted in hand at consistent speed in a straight line wearing a bit and bridle and three types of side reins (inelastic, stiff elastic, compliant elastic) were evaluated in random order at long, neutral, and short lengths. Strain gauge transducers (240 Hz) measured minimal, maximal and mean rein tension, rate of loading and impulse. The effects of rein type and length were evaluated using ANOVA with Bonferroni post hoc tests. Rein tension oscillated in a regular pattern with a peak during each diagonal stance phase. Within each rein type, minimal, maximal and mean tensions were higher with shorter reins. At neutral or short lengths, minimal tension increased and maximal tension decreased with elasticity of the reins. Short, inelastic reins had the highest maximal tension and rate of loading. Since the tension variables respond differently to rein elasticity at different lengths, it is recommended that a set of variables representing different aspects of rein tension should be reported. Copyright © 2010 Elsevier Ltd. All rights reserved.

  18. Resorption of lateral incisors during canine eruption: two clinical cases with focus on root length and heredity

    DEFF Research Database (Denmark)

    Zargham, Mostafa; Kjær, Inger

    2016-01-01

    Introduction: It is well-known that pressure from orthodontic appliance can provoke root resorption in dentitions with short roots. The purpose of this case report is to demonstrate two clinical cases with focus on root length in dentitions exposed due to pressure from erupting teeth...... resorption on her lateral incisor roots, extremely short roots in the central incisors, and short roots. The intraoral photos demonstrated light crowding in the maxilla. The orthopantomogram of the girl’s mother demonstrated extremely short roots in general. Conclusion: This pilot study indicates that short...... root length in general and abnormal incisor morphology are phenotypic traits that were characteristic for both girls who presented with severe lateral incisor resorption due to erupting canines. Furthermore, short roots were also demonstrated in the mothers. Accordingly, short root length in general...

  19. Evaluation of the Survival Rate and Bone Loss of Implants with Various Lengths

    Directory of Open Access Journals (Sweden)

    AR. Rokn

    2006-12-01

    Full Text Available Statement of Problem: The replacement of missing teeth with implant-associated restorations has become a widely used treatment modality in recent years. The length of dental implants may be a critical factor in achieving and maintaining osseointegration.Purpose: The aim of this study was to evaluate the survival rate and bone loss of dental implants with different lengthsMaterials and Methods: A retrospective cohort study was performed on 60 ITI-system implants, evenly distributed into three groups including 8, 10 and 12 mm high implants in the posterior segments of both jaws. Demographic information, oral hygiene,cigarette smoking, implant length, duration of implant placement (at least 24 months,bleeding on probing index and pocket probing depth were recorded for all participants.Bone loss was calculated using pre- and post-operative panoramic radiographs.Results: The mean rate of bone loss was different among the three groups and were found to be 0.21 (0.45, 0.3 (0.41 and 0.43 (0.55 mm in the 8, 10, and 12 mm high implants, respectively. Neither mean bone loss nor bleeding on probing index showed significant differences with implant length. A significant correlation was found between implant length and pocket probing depth (P<0.0001.Conclusion: The results of this study suggest that both short (8 mm high and long (10 or 12 mm high implants may be used with nearly equal success rates in the posterior segments of the jaws.

  20. Oligonucleotide Length-Dependent Formation of Virus-Like Particles.

    Science.gov (United States)

    Maassen, Stan J; de Ruiter, Mark V; Lindhoud, Saskia; Cornelissen, Jeroen J L M

    2018-05-23

    Understanding the assembly pathway of viruses can contribute to creating monodisperse virus-based materials. In this study, the cowpea chlorotic mottle virus (CCMV) is used to determine the interactions between the capsid proteins of viruses and their cargo. The assembly of the capsid proteins in the presence of different lengths of short, single-stranded (ss) DNA is studied at neutral pH, at which the protein-protein interactions are weak. Chromatography, electrophoresis, microscopy, and light scattering data show that the assembly efficiency and speed of the particles increase with increasing length of oligonucleotides. The minimal length required for assembly under the conditions used herein is 14 nucleotides. Assembly of particles containing such short strands of ssDNA can take almost a month. This slow assembly process enabled the study of intermediate states, which confirmed a low cooperative assembly for CCMV and allowed for further expansion of current assembly theories. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Certain features of FELs with short bunches

    International Nuclear Information System (INIS)

    Lebedev, A.N.

    2006-01-01

    The report is devoted to physics of free electron lasers operating in the short-wave domain where the bunch length could be less than the undulator length in the proper frame. Then the current component of the signal is locked within the bunch as in a cavity, while the electromagnetic component propagates freely. In contrast with gyrotrons where this regime can be of interest only for wavelengths comparable with the bunch length, we consider short waves in a bunch of arbitrary profile. Both amplification of an external harmonic signal and SASE regime, i.e. selective amplification of proper noises, are investigated

  2. The impact of precise robotic lesion length measurement on stent length selection: ramifications for stent savings.

    Science.gov (United States)

    Campbell, Paul T; Kruse, Kevin R; Kroll, Christopher R; Patterson, Janet Y; Esposito, Michele J

    2015-09-01

    Coronary stent deployment outcomes can be negatively impacted by inaccurate lesion measurement and inappropriate stent length selection (SLS). We compared visual estimate of these parameters to those provided by the CorPath 200® Robotic PCI System. Sixty consecutive patients who underwent coronary stent placement utilizing the CorPath System were evaluated. The treating physician assessed orthogonal images and provided visual estimates of lesion length and SLS. The robotic system was then used for the same measures. SLS was considered to be accurate when visual estimate and robotic measures were in agreement. Visual estimate SLSs were considered to be "short" or "long" if they were below or above the robotic-selected stents, respectively. Only 35% (21/60) of visually estimated lesions resulted in accurate SLS, whereas 33% (20/60) and 32% (19/60) of the visually estimated SLSs were long and short, respectively. In 5 cases (8.3%), 1 less stent was placed based on the robotic lesion measurement being shorter than the visual estimate. Visual estimate assessment of lesion length and SLS is highly variable with 65% of the cases being inaccurately measured when compared to objective measures obtained from the robotic system. The 32% of the cases where lesions were visually estimated to be short represents cases that often require the use of extra stents after the full lesion is not covered by 1 stent [longitudinal geographic miss (LGM)]. Further, these data showed that the use of the robotic system prevented the use of extra stents in 8.3% of the cases. Measurement of lesions with robotic PCI may reduce measurement errors, need for extra stents, and LGM. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Complexity analyses show two distinct types of nonlinear dynamics in short heart period variability recordings

    Science.gov (United States)

    Porta, Alberto; Bari, Vlasta; Marchi, Andrea; De Maria, Beatrice; Cysarz, Dirk; Van Leeuwen, Peter; Takahashi, Anielle C. M.; Catai, Aparecida M.; Gnecchi-Ruscone, Tomaso

    2015-01-01

    Two diverse complexity metrics quantifying time irreversibility and local prediction, in connection with a surrogate data approach, were utilized to detect nonlinear dynamics in short heart period (HP) variability series recorded in fetuses, as a function of the gestational period, and in healthy humans, as a function of the magnitude of the orthostatic challenge. The metrics indicated the presence of two distinct types of nonlinear HP dynamics characterized by diverse ranges of time scales. These findings stress the need to render more specific the analysis of nonlinear components of HP dynamics by accounting for different temporal scales. PMID:25806002

  4. Effects of epidural analgesia on labor length, instrumental delivery, and neonatal short-term outcome.

    Science.gov (United States)

    Hasegawa, Junichi; Farina, Antonio; Turchi, Giovanni; Hasegawa, Yuko; Zanello, Margherita; Baroncini, Simonetta

    2013-02-01

    We aimed to clarify whether the short-term adverse neonatal outcomes associated with epidural analgesia are due to the epidural analgesia itself or to the instrumental delivery. A retrospective case-control study was conducted to evaluate the relationship between epidural analgesia, labor length, and perinatal outcomes. A total of 350 pregnant women at term who delivered under epidural analgesia (cases) were compared with 1400 patients without epidural analgesia (controls). Vacuum extraction (6.5 vs. 2.9 %) and cesarean section (19.9 vs. 11.1 %) were more frequently performed in the cases than controls (p neonatal variables stratified by mode of delivery were not different in cases and controls, except for a slightly lower umbilical arterial pH in spontaneous delivery for the cases group. However, the Apgar scores and umbilical arterial pH were significantly lower in the neonates delivered by vacuum extraction compared with those in the neonates delivered by spontaneous delivery or cesarean section, regardless of whether epidural analgesia was performed. A multivariable analysis showed that vacuum extraction much more consistently affected the arterial pH than the analgesia itself (the β coefficients were -0.036 for epidural analgesia vs. -0.050 for vacuum extraction). Epidural analgesia was associated with slowly progressing labor, thus resulting in an increased rate of instrumental delivery. This instrumental delivery appears to adversely affect the neonatal outcomes more strongly than the analgesia itself.

  5. Shorter leukocyte telomere length is associated with higher risk of infections

    DEFF Research Database (Denmark)

    Helby, Jens; Nordestgaard, Børge G; Benfield, Thomas

    2017-01-01

    In the general population, older age is associated with short leukocyte telomere length and with high risk of infections. In a recent study of allogeneic hematopoietic cell transplantation for severe aplastic anemia, long donor leukocyte telomere length was associated with improved survival...

  6. Exon 3-deleted/full-length growth hormone receptor polymorphism genotype frequencies in Spanish short small-for-gestational-age (SGA) children and adolescents (n = 247) and in an adult control population (n = 289) show increased fl/fl in short SGA.

    Science.gov (United States)

    Audí, Laura; Esteban, Cristina; Carrascosa, Antonio; Espadero, Rosa; Pérez-Arroyo, Annalisa; Arjona, Rosa; Clemente, María; Wollmann, Hartmut; Fryklund, Linda; Parodi, Luis A

    2006-12-01

    A polymorphism in the human GH receptor gene (d3/fl-GHR) resulting in genomic deletion of exon 3 has been associated with the degree of height increase in response to GH therapy. The objective of the study was to evaluate the frequencies of d3/fl-GHR polymorphism genotypes in control and short small-for-gestational-age (SGA) populations. An adult control population with heights normally distributed (ACPNH) between -2 and +2 sd score (SDS) and a short non-GH-deficient SGA child population were selected. Thirty Spanish hospitals participated in the selection of the short non-GH-deficient SGA children in the setting of a controlled, randomized trial, and one of these hospitals selected the ACPNH. CONTROLS AND PATIENTS: Two hundred eighty-nine adult subjects of both sexes constituted the ACPNH and 247 children and adolescents of both sexes the short SGA patients. Heights and weights were recorded in the ACPNH, and auxologic and biochemical data were recorded at each hospital for the SGA patients; d3/fl-GHR genotypes were determined and data analyzed in a single hospital. In short SGA patients, d3/fl-GHR genotype frequencies were significantly different from those in ACPNH, with a higher frequency of fl/fl genotype (P or=-2 SDS, n = 60). Our data showed significant differences in the frequency distribution of the d3/fl-GHR genotypes between a normally distributed adult height population and short SGA children, with the biologically less active fl/fl genotype being almost twice as frequent in SGA patients. These data suggest that the d3/fl-GHR polymorphism might be considered among the factors that contribute to the phenotypic expression of growth.

  7. Stimulated brillouin backscatter of a short-pulse laser

    International Nuclear Information System (INIS)

    Hinkel, D.E.; Williams, E.A.; Berger, R.L.

    1994-01-01

    Stimulated Brillouin backscattering (SBBS) from a short-pulse laser, where the pulse length is short compared to the plasma length, is found to be qualitatively different than in the long pulse regime, where the pulse length is long compared to the plasma length. We find that after an initial transient of order the laser pulse length transit time, the instability reaches a steady state in the variables x' = x - V g t, t' = t, where V g is the pulse group velocity. In contrast, SBBS in a long pulse can be absolutely unstable and grows indefinitely, or until nonlinearities intervene. We find that the motion of the laser pulse induces Doppler related effects that substantially modify the backscattered spectrum at higher intensities, where the instability is strongly coupled (i.e. , has a growth rate large compared to the ion acoustic frequency)

  8. Zero-point length from string fluctuations

    International Nuclear Information System (INIS)

    Fontanini, Michele; Spallucci, Euro; Padmanabhan, T.

    2006-01-01

    One of the leading candidates for quantum gravity, viz. string theory, has the following features incorporated in it. (i) The full spacetime is higher-dimensional, with (possibly) compact extra-dimensions; (ii) there is a natural minimal length below which the concept of continuum spacetime needs to be modified by some deeper concept. On the other hand, the existence of a minimal length (zero-point length) in four-dimensional spacetime, with obvious implications as UV regulator, has been often conjectured as a natural aftermath of any correct quantum theory of gravity. We show that one can incorporate the apparently unrelated pieces of information-zero-point length, extra-dimensions, string T-duality-in a consistent framework. This is done in terms of a modified Kaluza-Klein theory that interpolates between (high-energy) string theory and (low-energy) quantum field theory. In this model, the zero-point length in four dimensions is a 'virtual memory' of the length scale of compact extra-dimensions. Such a scale turns out to be determined by T-duality inherited from the underlying fundamental string theory. From a low energy perspective short distance infinities are cutoff by a minimal length which is proportional to the square root of the string slope, i.e., α ' . Thus, we bridge the gap between the string theory domain and the low energy arena of point-particle quantum field theory

  9. Your Medical Records

    Science.gov (United States)

    ... hear medical people call these EHRs — short for electronic health records . Electronic records make it easier for all your doctors ... doctor's office is trying to protect a patient's privacy or safety. For example, they may say no ...

  10. Length-weight relationships, condition factors and relative weight of ...

    African Journals Online (AJOL)

    The aim of this study was to record the length-weight relationship parameters and condition factors for some commercially important fish of Bushehr coastal waters of Persian Gulf. The length-weight relationships were calculated for five species caught during fishing surveys using different types of fishing gears (trawls, pots ...

  11. Apo AIV and Citrulline Plasma Concentrations in Short Bowel Syndrome Patients: The Influence of Short Bowel Anatomy

    Science.gov (United States)

    Targarona, Jordi; Ruiz, Jorge; García, Natalia; Oró, Denise; García-Villoria, Judit; Creus, Gloria; Pita, Ana M.

    2016-01-01

    Introduction Parenteral nutrition (PN) dependence in short bowel syndrome (SBS) patients is linked to the functionality of the remnant small bowel (RSB). Patients may wean off PN following a period of intestinal adaptation that restores this functionality. Currently, plasma citrulline is the standard biomarker for monitoring intestinal functionality and adaptation. However, available studies reveal that the relationship the biomarker with the length and function of the RSB is arguable. Thus, having additional biomarkers would improve pointing out PN weaning. Aim By measuring concomitant changes in citrulline and the novel biomarker apolipoprotein AIV (Apo AIV), as well as taking into account the anatomy of the RSB, this exploratory study aims to a better understanding of the intestinal adaptation process and characterization of the SBS patients under PN. Methods Thirty four adult SBS patients were selected and assigned to adapted (aSBS) and non-adapted (nSBS) groups after reconstructive surgeries. Remaining jejunum and ileum lengths were recorded. The aSBS patients were either on an oral diet (ORAL group), those with intestinal insufficiency, or on oral and home parenteral nutrition (HPN group), those with chronic intestinal failure. Apo AIV and citrulline were analyzed in plasma samples after overnight fasting. An exploratory ROC analysis using citrulline as gold standard was performed. Results Biomarkers, Apo AIV and citrulline showed a significant correlation with RSBL in aSBS patients. In jejuno-ileocolic patients, only Apo AIV correlated with RSBL (rb = 0.54) and with ileum length (rb = 0.84). In patients without ileum neither biomarker showed any correlation with RSBL. ROC analysis indicated the Apo AIV cut-off value to be 4.6 mg /100 mL for differentiating between the aSBS HPN and ORAL groups. Conclusions Therefore, in addition to citrulline, Apo AIV can be set as a biomarker to monitor intestinal adaptation in SBS patients. As short bowel anatomy is shown

  12. Verbal Short-Term Memory Span in Speech-Disordered Children: Implications for Articulatory Coding in Short-Term Memory.

    Science.gov (United States)

    Raine, Adrian; And Others

    1991-01-01

    Children with speech disorders had lower short-term memory capacity and smaller word length effect than control children. Children with speech disorders also had reduced speech-motor activity during rehearsal. Results suggest that speech rate may be a causal determinant of verbal short-term memory capacity. (BC)

  13. Extreme telomere length dimorphism in the Tasmanian devil and related marsupials suggests parental control of telomere length.

    Directory of Open Access Journals (Sweden)

    Hannah S Bender

    Full Text Available Telomeres, specialised structures that protect chromosome ends, play a critical role in preserving chromosome integrity. Telomere dynamics in the Tasmanian devil (Sarcophilus harrisii are of particular interest in light of the emergence of devil facial tumour disease (DFTD, a transmissible malignancy that causes rapid mortality and threatens the species with extinction. We used fluorescent in situ hybridisation to investigate telomere length in DFTD cells, in healthy Tasmanian devils and in four closely related marsupial species. Here we report that animals in the Order Dasyuromorphia have chromosomes characterised by striking telomere length dimorphism between homologues. Findings in sex chromosomes suggest that telomere length dimorphism may be regulated by events in the parental germlines. Long telomeres on the Y chromosome imply that telomere lengthening occurs during spermatogenesis, whereas telomere diminution occurs during oogenesis. Although found in several somatic cell tissue types, telomere length dimorphism was not found in DFTD cancer cells, which are characterised by uniformly short telomeres. This is, to our knowledge, the first report of naturally occurring telomere length dimorphism in any species and suggests a novel strategy of telomere length control. Comparative studies in five distantly related marsupials and a monotreme indicate that telomere dimorphism evolved at least 50 million years ago.

  14. Length of urethra in the Indian adult male population

    Directory of Open Access Journals (Sweden)

    Venkatesh Krishnamoorthy

    2012-01-01

    Full Text Available Objective: The urethral length has not been measured in the Indian population. Even the international literature in this arena is very sparse. This paper is an attempt to develop a simple anatomical database for urethral length. Materials and Methods: Between January 2010 and April 2011, the urethral lengths of 422 adult male patients who required catheterization as part of regular treatment at our hospital, were recorded after obtaining consent from the patients and from the scientific and ethics review boards of the institution. Patients with history of prostatic or urethral abnormalities were excluded. The balloon of a sterile Foley′s catheter was inflated using 10 cc of saline. The length from the junction of the balloon to the ′Y′ junction of the Foley was measured. The catheter was then passed into the bladder and re-inflated to same volume. The penis was gently straightened and the length of the catheter outside the penis was measured till the premarked point at the ′Y′ junction. Subtracting this from the original length gave the length of the urethra. Results: The mean length of the urethra was 17.55 + 1.42 cm with a range between 14 and 22.5 cm. Conclusions: Literature in which the length of the normal adult male urethra is recorded for a significant sample size is very scarce. Our data adds to basic anatomic information of the male urethra specific to the Indian population. Statistical Methods: Descriptive statistical analysis was performed. The non-linear regression analysis was employed to find the normative values of urethral length according to age class.

  15. Quantifying Short-Chain Chlorinated Paraffin Congener Groups

    NARCIS (Netherlands)

    Yuan, Bo; Bogdal, Christian; Berger, Urs; MacLeod, Matthew; Gebbink, Wouter A.; Alsberg, Tomas; Wit, de Cynthia A.

    2017-01-01

    Accurate quantification of short-chain chlorinated paraffins (SCCPs) poses an exceptional challenge to analytical chemists. SCCPs are complex mixtures of chlorinated alkanes with variable chain length and chlorination level; congeners with a fixed chain length (n) and number of chlorines (m) are

  16. The Long and the Short of It: The Use of Short Films in the German Classroom

    Science.gov (United States)

    Sundquist, John

    2010-01-01

    This article focuses on the benefits of using short film in the German classroom at the secondary or post-secondary level. The article addresses a number of characteristics of short films that lend themselves well to the classroom, including their abbreviated length, artistic innovation, and compact storytelling. In addition to discussing specific…

  17. Scale Length of the Galactic Thin Disk

    Indian Academy of Sciences (India)

    tribpo

    thin disk density scale length, hR, is rather short (2.7 ± 0.1 kpc). Key words. ... The 2MASS near infrared data provide, for the first time, deep star counts on a ... peaks allows to adjust the spatial extinction law in the model. ... probability that fi.

  18. Does hair coat length affect flea infestation in naturally infested dogs?

    Science.gov (United States)

    Silva, Guilherme Araujo Collares da; Lins, Luciana Araujo; Irala, Márcio Josué Costa; Cárcamo, Marcial Corrêa; Ribeiro, Paulo Bretanha

    2016-01-01

    The Siphonaptera are parasitic insects of endothermic animals and Ctenocephalides felis and Pulex irritans are important parasites of dogs. This study evaluated the effect of hair coat length and time of year on the population size of C. felis and P. irritans in naturally infested dogs. Fleas were collected from 14 dogs on a monthly basis for a year (February 2015 to January 2016) at a rural property in Bagé, Rio Grande do Sul, Brazil. The dogs were divided into two groups based on hair coat length: short coat (coat length coat (coat length > 5.0 cm, n= 7). In total, 2057 fleas were collected, 1541 of which were C. felis (74.91%) and 516 were P. irritans (25.08%). The number of C. felis and P. irritans individuals was significantly affected by hair coat length and time of year. The variation in flea numbers over the study months was higher in long-coated than in short-coated dogs for the two flea species and flea numbers increased with increasing mean monthly temperatures. The results provide a better understanding of behavioral aspects of flea communities in dogs and may help develop control strategies targeting these parasites.

  19. Is the word-length effect linked to subvocal rehearsal?

    Science.gov (United States)

    Jacquemot, Charlotte; Dupoux, Emmanuel; Bachoud-Lévi, Anne-Catherine

    2011-04-01

    Models of phonological short-term memory (pSTM) generally distinguish between two components: a phonological buffer and a subvocal rehearsal. Evidence for these two components comes, respectively, from the phonological similarity effect and the word-length effect which disappears under articulatory suppression. But alternative theories posit that subvocal rehearsal is only an optional component of the pSTM. According to them, the depletion of the length effect under articulatory suppression results from the interference of the self-produced speech rather than the disruption of subvocal rehearsal. In order to disentangle these two theories, we tested two patients with a short-term memory deficit. FA, who presents a pseudoword repetition deficit, and FL, who does not. FA's deficit allowed for the observance of an ecological case of subvocal rehearsal disruption without any articulatory suppression task. FA's performance in pSTM tasks reveals as controls a phonological similarity effect, and contrary to controls no word-length effect. In contrast, the second patient, FL, exhibits the same effects as control subjects. This result is in accordance with models of pSTM in which the word-length effect emerges from subvocal rehearsal and disappears when this latter is disrupted. Copyright © 2010 Elsevier Srl. All rights reserved.

  20. Influence of day-length and isolates of Phytophthora infestans on field resistance to late blight of potato.

    Science.gov (United States)

    Mihovilovich, E; Munive, S; Bonierbale, M

    2010-04-01

    Main and interaction effects of day-length and pathogen isolate on the reaction and expression of field resistance to Phytophthora infestans were analyzed in a sample of standard clones for partial resistance to potato late blight, and in the BCT mapping population derived from a backcross of Solanum berthaultii to Solanum tuberosum. Detached leaves from plants grown in field plots exposed to short- and long day-length conditions were independently inoculated with two P. infestans isolates and incubated in chambers under short- and long photoperiods, respectively. Lesion growth rate (LGR) was used for resistance assessment. Analysis of variance revealed a significant contribution of genotype x isolate x day-length interaction to variation in LGR indicating that field resistance of genotypes to foliar late blight under a given day-length depended on the infecting isolate. An allele segregating from S. berthaultii with opposite effects on foliar resistance to late blight under long- and short day-lengths, respectively, was identified at a quantitative trait locus (QTL) that mapped on chromosome 1. This allele was associated with positive (decreased resistance) and negative (increased resistance) additive effects on LGR, under short- and long day-length conditions, respectively. Disease progress on whole plants inoculated with the same isolate under field conditions validated the direction of its effect in short day-length regimes. The present study suggests the occurrence of an isolate-specific QTL that displays interaction with isolate behavior under contrasting environments, such as those with different day-lengths. This study highlights the importance of exposing genotypes to a highly variable population of the pathogen under contrasting environments when stability to late blight resistance is to be assessed or marker-assisted selection is attempted for the manipulation of quantitative resistance to late blight.

  1. GINGER simulations of short-pulse effects in the LEUTL FEL

    International Nuclear Information System (INIS)

    Huang, Z.; Fawley, W.M.

    2001-01-01

    While the long-pulse, coasting beam model is often used in analysis and simulation of self-amplified spontaneous emission (SASE) free-electron lasers (FELs), many current SASE demonstration experiments employ relatively short electron bunches whose pulse length is on the order of the radiation slippage length. In particular, the low-energy undulator test line (LEUTL) FEL at the Advanced Photon Source has recently lased and nominally saturated in both visible and near-ultraviolet wavelength regions with a sub-ps pulse length that is somewhat shorter than the total slippage length in the 22-m undulator system. In this paper we explore several characteristics of the short pulse regime for SASE FELs with the multidimensional, time-dependent simulation code GINGER, concentrating on making a direct comparison with the experimental results from LEUTL. Items of interest include the radiation gain length, pulse energy, saturation position, and spectral bandwidth. We address the importance of short-pulse effects when scaling the LEUTL results to proposed x-ray FELs and also briefly discuss the possible importance of coherent spontaneous emission at startup

  2. All-optical, thermo-optical path length modulation based on the vanadium-doped fibers.

    Science.gov (United States)

    Matjasec, Ziga; Campelj, Stanislav; Donlagic, Denis

    2013-05-20

    This paper presents an all-fiber, fully-optically controlled, optical-path length modulator based on highly absorbing optical fiber. The modulator utilizes a high-power 980 nm pump diode and a short section of vanadium-co-doped single mode fiber that is heated through absorption and a non-radiative relaxation process. The achievable path length modulation range primarily depends on the pump's power and the convective heat-transfer coefficient of the surrounding gas, while the time response primarily depends on the heated fiber's diameter. An absolute optical length change in excess of 500 µm and a time-constant as short as 11 ms, were demonstrated experimentally. The all-fiber design allows for an electrically-passive and remote operation of the modulator. The presented modulator could find use within various fiber-optics systems that require optical (remote) path length control or modulation.

  3. The effect of epoch length on estimated EEG functional connectivity and brain network organisation

    Science.gov (United States)

    Fraschini, Matteo; Demuru, Matteo; Crobe, Alessandra; Marrosu, Francesco; Stam, Cornelis J.; Hillebrand, Arjan

    2016-06-01

    Objective. Graph theory and network science tools have revealed fundamental mechanisms of functional brain organization in resting-state M/EEG analysis. Nevertheless, it is still not clearly understood how several methodological aspects may bias the topology of the reconstructed functional networks. In this context, the literature shows inconsistency in the chosen length of the selected epochs, impeding a meaningful comparison between results from different studies. Approach. The aim of this study was to provide a network approach insensitive to the effects that epoch length has on functional connectivity and network reconstruction. Two different measures, the phase lag index (PLI) and the amplitude envelope correlation (AEC) were applied to EEG resting-state recordings for a group of 18 healthy volunteers using non-overlapping epochs with variable length (1, 2, 4, 6, 8, 10, 12, 14 and 16 s). Weighted clustering coefficient (CCw), weighted characteristic path length (L w) and minimum spanning tree (MST) parameters were computed to evaluate the network topology. The analysis was performed on both scalp and source-space data. Main results. Results from scalp analysis show a decrease in both mean PLI and AEC values with an increase in epoch length, with a tendency to stabilize at a length of 12 s for PLI and 6 s for AEC. Moreover, CCw and L w show very similar behaviour, with metrics based on AEC more reliable in terms of stability. In general, MST parameters stabilize at short epoch lengths, particularly for MSTs based on PLI (1-6 s versus 4-8 s for AEC). At the source-level the results were even more reliable, with stability already at 1 s duration for PLI-based MSTs. Significance. The present work suggests that both PLI and AEC depend on epoch length and that this has an impact on the reconstructed network topology, particularly at the scalp-level. Source-level MST topology is less sensitive to differences in epoch length, therefore enabling the comparison of brain

  4. Mature clustered, regularly interspaced, short palindromic repeats RNA (crRNA) length is measured by a ruler mechanism anchored at the precursor processing site.

    Science.gov (United States)

    Hatoum-Aslan, Asma; Maniv, Inbal; Marraffini, Luciano A

    2011-12-27

    Precise RNA processing is fundamental to all small RNA-mediated interference pathways. In prokaryotes, clustered, regularly interspaced, short palindromic repeats (CRISPR) loci encode small CRISPR RNAs (crRNAs) that protect against invasive genetic elements by antisense targeting. CRISPR loci are transcribed as a long precursor that is cleaved within repeat sequences by CRISPR-associated (Cas) proteins. In many organisms, this primary processing generates crRNA intermediates that are subject to additional nucleolytic trimming to render mature crRNAs of specific lengths. The molecular mechanisms underlying this maturation event remain poorly understood. Here, we defined the genetic requirements for crRNA primary processing and maturation in Staphylococcus epidermidis. We show that changes in the position of the primary processing site result in extended or diminished maturation to generate mature crRNAs of constant length. These results indicate that crRNA maturation occurs by a ruler mechanism anchored at the primary processing site. We also show that maturation is mediated by specific cas genes distinct from those genes involved in primary processing, showing that this event is directed by CRISPR/Cas loci.

  5. Length dependence of rectification in organic co-oligomer spin rectifiers

    International Nuclear Information System (INIS)

    Hu Gui-Chao; Zhang Zhao; Li Ying; Ren Jun-Feng; Wang Chuan-Kui

    2016-01-01

    The rectification ratio of organic magnetic co-oligomer diodes is investigated theoretically by changing the molecular length. The results reveal two distinct length dependences of the rectification ratio: for a short molecular diode, the charge-current rectification changes little with the increase of molecular length, while the spin-current rectification is weakened sharply by the length; for a long molecular diode, both the charge-current and spin-current rectification ratios increase quickly with the length. The two kinds of dependence switch at a specific length accompanied with an inversion of the rectifying direction. The molecular ortibals and spin-resolved transmission analysis indicate that the dominant mechanism of rectification suffers a change at this specific length, that is, from asymmetric shift of molecular eigenlevels to asymmetric spatial localization of wave functions upon the reversal of bias. This work demonstrates a feasible way to control the rectification in organic co-oligomer spin diodes by adjusting the molecular length. (paper)

  6. Enhanced ductility of Mg–3Al–1Zn alloy reinforced with short length multi-walled carbon nanotubes using a powder metallurgy method

    Directory of Open Access Journals (Sweden)

    Muhammad Rashad

    2015-08-01

    Full Text Available Mg–3Al–1Zn–CNTs composites, with different weight fractions (0.25–1.0 wt% of carbon nanotubes (CNTs were successfully fabricated via a powder metallurgy method. The processing parameters were adopted in such a way to have uniform dispersion of short length CNTs without any damage, as well as refined and dissolved β phases structures throughout the composite matrix. The composite exhibited impressive increase in microhardness (about +23% and tensile failure strain value (about +98% without significant compromise in tensile strength, compared to the un-reinforced Mg–3Al–1Zn alloy. The synthesized composites can be used in automotive and aerospace industries due to their low density and high specific strength.

  7. Leg Length, Body Proportion, and Health: A Review with a Note on Beauty

    Science.gov (United States)

    Bogin, Barry; Varela-Silva, Maria Inês

    2010-01-01

    Decomposing stature into its major components is proving to be a useful strategy to assess the antecedents of disease, morbidity and death in adulthood. Human leg length (femur + tibia), sitting height (trunk length + head length) and their proportions, for example, (leg length/stature), or the sitting height ratio (sitting height/stature × 100), among others) are associated with epidemiological risk for overweight (fatness), coronary heart disease, diabetes, liver dysfunction and certain cancers. There is also wide support for the use of relative leg length as an indicator of the quality of the environment for growth during infancy, childhood and the juvenile years of development. Human beings follow a cephalo-caudal gradient of growth, the pattern of growth common to all mammals. A special feature of the human pattern is that between birth and puberty the legs grow relatively faster than other post-cranial body segments. For groups of children and youth, short stature due to relatively short legs (i.e., a high sitting height ratio) is generally a marker of an adverse environment. The development of human body proportions is the product of environmental x genomic interactions, although few if any specific genes are known. The HOXd and the short stature homeobox-containing gene (SHOX) are genomic regions that may be relevant to human body proportions. For example, one of the SHOX related disorders is Turner syndrome. However, research with non-pathological populations indicates that the environment is a more powerful force influencing leg length and body proportions than genes. Leg length and proportion are important in the perception of human beauty, which is often considered a sign of health and fertility. PMID:20617018

  8. Nutritive support in short Bowel syndrome (sbs

    Directory of Open Access Journals (Sweden)

    Simić Dušica

    2003-01-01

    Full Text Available Short bowel syndrome most commonly result after bowel resection for necrosis of the bowel. It may be caused by arterial or venous thrombosis, volvolus and in children, necrotizing enterocolitis. The other causes are Crohn,s disease intestinal atresia. The factors influencing the risk on short bowel syndrome are the remaining length of the small bowel, the age of onset, the length of the colon, the presence or absence of the ileo-coecal valve and the time after resection. Besides nutritional deficiencies there some other consequences of extensive resections of the small intestine (gastric acid hypersecretion, d-lactic acidosis, nephrolithiasis, cholelithiasis, which must be diagnosed, treated, and if possible, prevented. With current therapy most patients with short bowel have normal body mass index and good quality of life.

  9. Metal halide arc discharge lamp having short arc length

    Science.gov (United States)

    Muzeroll, Martin E. (Inventor)

    1994-01-01

    A metal halide arc discharge lamp includes a sealed light-transmissive outer jacket, a light-transmissive shroud located within the outer jacket and an arc tube assembly located within the shroud. The arc tube assembly includes an arc tube, electrodes mounted within the arc tube and a fill material for supporting an arc discharge. The electrodes have a spacing such that an electric field in a range of about 60 to 95 volts per centimeter is established between the electrodes. The diameter of the arc tube and the spacing of the electrodes are selected to provide an arc having an arc diameter to arc length ratio in a range of about 1.6 to 1.8. The fill material includes mercury, sodium iodide, scandium tri-iodide and a rare gas, and may include lithium iodide. The lamp exhibits a high color rendering index, high lumen output and high color temperature.

  10. Increased hallux angle in children and its association with insufficient length of footwear: A community based cross-sectional study

    Directory of Open Access Journals (Sweden)

    Kundi Michael

    2009-12-01

    Full Text Available Abstract Background Wearing shoes of insufficient length during childhood has often been cited as leading to deformities of the foot, particularly to the development of hallux valgus disorders. Until now, these assumptions have not been confirmed through scientific research. This study aims to investigate whether this association can be statistically proven, and if children who wear shoes of insufficient length actually do have a higher risk of a more pronounced lateral deviation of the hallux. Methods 858 pre-school children were included in the study. The study sample was stratified by sex, urban/rural areas and Austrian province. The hallux angle and the length of the feet were recorded. The inside length of the children's footwear (indoor shoes worn in pre-school and outdoor shoes were assessed. Personal data and different anthropometric measurements were taken. The risk of hallux valgus deviation was statistically tested by a stepwise logistic regression analysis and the relative risk (odds ratio for a hallux angle ≥ 4 degrees was calculated. Results Exact examinations of the hallux angle could be conducted on a total of 1,579 individual feet. Only 23.9% out of 1,579 feet presented a straight position of the great toe. The others were characterized by lateral deviations (valgus position at different degrees, equalling 10 degrees or greater in 14.2% of the children's feet. 88.8% of 808 children examined wore indoor footwear that was of insufficient length, and 69.4% of 812 children wore outdoor shoes that were too short. A significant relationship was observed between the lengthwise fit of the shoes and the hallux angle: the shorter the shoe, the higher the value of the hallux angle. The relative risk (odds ratio of a lateral hallux deviation of ≥ 4 degrees in children wearing shoes of insufficient length was significantly increased. Conclusions There is a significant relationship between the hallux angle in children and footwear that is

  11. Increased hallux angle in children and its association with insufficient length of footwear: A community based cross-sectional study

    Science.gov (United States)

    2009-01-01

    Background Wearing shoes of insufficient length during childhood has often been cited as leading to deformities of the foot, particularly to the development of hallux valgus disorders. Until now, these assumptions have not been confirmed through scientific research. This study aims to investigate whether this association can be statistically proven, and if children who wear shoes of insufficient length actually do have a higher risk of a more pronounced lateral deviation of the hallux. Methods 858 pre-school children were included in the study. The study sample was stratified by sex, urban/rural areas and Austrian province. The hallux angle and the length of the feet were recorded. The inside length of the children's footwear (indoor shoes worn in pre-school and outdoor shoes) were assessed. Personal data and different anthropometric measurements were taken. The risk of hallux valgus deviation was statistically tested by a stepwise logistic regression analysis and the relative risk (odds ratio) for a hallux angle ≥ 4 degrees was calculated. Results Exact examinations of the hallux angle could be conducted on a total of 1,579 individual feet. Only 23.9% out of 1,579 feet presented a straight position of the great toe. The others were characterized by lateral deviations (valgus position) at different degrees, equalling 10 degrees or greater in 14.2% of the children's feet. 88.8% of 808 children examined wore indoor footwear that was of insufficient length, and 69.4% of 812 children wore outdoor shoes that were too short. A significant relationship was observed between the lengthwise fit of the shoes and the hallux angle: the shorter the shoe, the higher the value of the hallux angle. The relative risk (odds ratio) of a lateral hallux deviation of ≥ 4 degrees in children wearing shoes of insufficient length was significantly increased. Conclusions There is a significant relationship between the hallux angle in children and footwear that is too short in length. The

  12. Short bunch length detector for ion beam with high bunch density

    International Nuclear Information System (INIS)

    Tron, A.M.; Shako, V.V.

    1993-01-01

    The secondary electron rf monitors for short ion bunch phase distribution measurements are presented. Construction particularities of the monitors, influence of space charge of both the primary and the secondary electron beams on the phase resolution, thermal regime of the target during beam-target interaction are considered

  13. Increased Body Mass Index, Elevated C-reactive Protein, and Short Telomere Length

    DEFF Research Database (Denmark)

    Rode, Line; Nordestgaard, Børge G; Weischer, Maren

    2014-01-01

    -reactive protein. SETTING AND DESIGN: We studied 45,069 individuals from the Copenhagen General Population Study with measurements of leukocyte telomere length, BMI, and C-reactive protein in a Mendelian randomization study. Using the three obesity-associated polymorphisms FTO rs9939609, MC4R rs17782313, and TMEM...

  14. Performance of short ECG recordings twice daily to detect paroxysmal atrial fibrillation in stroke and transient ischemic attack patients

    DEFF Research Database (Denmark)

    Poulsen, Mai Bang; Binici, Zeynep; Domínguez, Helena

    2017-01-01

    Aims Prolonged cardiac monitoring after stroke is recommended though there is no consensus on optimal methods. Short-term ECG recordings with a "thumb-ECG" device have shown promising preliminary results regarding effectiveness and cost benefit. We aimed to examine the performance of thumb...... methods was poor and the trial was not powered to detect a minor difference between the devices. The inter-observer agreement for the thumb-ECG was substantial. www.clinicalTrials.gov UI: NCT02261766....

  15. Short-term Outcomes Following Concussion in the NFL: A Study of Player Longevity, Performance, and Financial Loss.

    Science.gov (United States)

    Navarro, Sergio M; Sokunbi, Olumide F; Haeberle, Heather S; Schickendantz, Mark S; Mont, Michael A; Figler, Richard A; Ramkumar, Prem N

    2017-11-01

    A short-term protocol for evaluation of National Football League (NFL) athletes incurring concussion has yet to be fully defined and framed in the context of the short-term potential team and career longevity, financial risk, and performance. To compare the short-term career outcomes for NFL players with concussions by analyzing the effect of concussions on (1) franchise release rate, (2) career length, (3) salary, and (4) performance. Cohort study; Level of evidence, 3. NFL player transaction records and publicly available injury reports from August 2005 to January 2016 were analyzed. All players sustaining documented concussions were evaluated for a change to inactive or DNP ("did not participate") status. A case-control design compared franchise release rates and remaining NFL career span. Career length was analyzed via survival analysis. Salary and performance differences were analyzed with publicly available contract data and a performance-scoring algorithm based on position/player level. Of the 5894 eligible NFL players over the 11-year period, 307 sustained publicly reported concussions resulting in the DNP injury protocol. Analysis of the probability of remaining in the league demonstrated a statistically significantly shorter career length for the concussion group at 3 and 5 years after concussion. The year-over-year change in contract value for the concussion group resulted in a mean overall salary reduction of $300,000 ± $1,300,000 per year (interquartile range, -$723,000 to $450,000 per year). The performance score reduction for all offensive scoring players sustaining concussions was statistically significant. This retrospective study demonstrated that NFL players who sustain a concussion face a higher overall franchise release rate and shorter career span. Players who sustained concussions may incur significant salary reductions and perform worse after concussion. Short-term reductions in longevity, performance, and salary after concussion exist and

  16. Measurement of the dechanneling length for high-energy negative pions

    International Nuclear Information System (INIS)

    Scandale, W.; Losito, R.; Bagli, E.; Bandiera, L.; Dalpiaz, P.; Fiorini, M.; Guidi, V.; Mazzolari, A.; Vincenzi, D.; Della Mea, G.; Vallazza, E.; Afonin, A.G.; Chesnokov, Yu.A.; Maisheev, V.A.; Yazynin, I.A.; Kovalenko, A.D.; Taratin, A.M.; Denisov, A.S.; Gavrikov, Yu.A.; Ivanov, Yu.M.

    2013-01-01

    We studied the dechanneling length of 150 GeV/cπ − interacting with a short bent silicon crystal. Dechanneling length measures the rate and the strength of incoherent interactions of channeled particles in a crystal. The mechanism of dechanneling of negatively charged particles has been elucidated through simulation and experiment. It was found that the dechanneling length for negative particles is comparable to the nuclear dechanneling length for positive charges. Indeed, dechanneling of negative particles occurs as a result of incoherent interactions with the nuclei because the trajectories of such particles always intersect atomic planes, explaining the lower channeling efficiency for such particles. Obtained results can be useful for the design of crystals for manipulating high-energy negative particle beams through channeling

  17. Racial/ethnic variations in perineal length and association with perineal lacerations: a prospective cohort study.

    Science.gov (United States)

    Yeaton-Massey, Amanda; Wong, Luchin; Sparks, Teresa N; Handler, Stephanie J; Meyer, Michelle R; Granados, Jesus M; Stasenko, Marina; Sit, Anita; Caughey, Aaron B

    2015-02-01

    To examine the association between race/ethnicity, perineal length and the risk of perineal laceration. This is a prospective cohort study of a diverse group of women with singleton gestations in the third trimester of pregnancy. Perineal length was measured and mean values calculated for several racial/ethnic groups. Chi-squared analyses were used to examine rates of severe perineal laceration (third or fourth degree laceration) by race/ethnicity among women considered to have a short perineal length. Further, subgroup analyses were performed comparing nulliparas to multiparas. Among 344 study participants, there was no statistically significant difference in mean perineal length by race/ethnicity (White 4.0 ± 1.1 cm, African-American 3.7 ± 1.0 cm, Latina 4.1 ± 1.1 cm, Asian 3.8 ± 1.0 cm, and other/unknown 4.0 ± 0.9 cm). Considering parity, more multiparous Asian and African-American women had a short perineal length (20.7 and 23.5%, respectively, p = 0.05). Finally, the rate of severe perineal lacerations in our cohort was 2.6% overall, but was 8.2% among Asian women (p = 0.04). We did not find a relationship between short perineal length and risk of severe perineal laceration with vaginal delivery, or a difference in mean perineal length by maternal race/ethnicity. However, we did find that women of different racial/ethnic groups have varying rates of severe perineal laceration, with Asian women comprising the highest proportion.

  18. Investment, Reprocurement and Franchise Contract Length in the British Railway Industry

    OpenAIRE

    Affuso, Luisa; Newbery, David M G

    2000-01-01

    This Paper studies the interaction between repeated auctions of rail franchises of different lengths, uncertainty, and incentives for investment in rolling stock, following the privatization of British Rail. Theoretical predictions are tested empirically using a unique panel of data. Theory suggests that short franchise lengths reduce incentives to invest in specific assets. Our empirical results suggest that competition and strategic behaviour at the re-procurement stage can create incentive...

  19. The word-length effect and disyllabic words.

    Science.gov (United States)

    Lovatt, P; Avons, S E; Masterson, J

    2000-02-01

    Three experiments compared immediate serial recall of disyllabic words that differed on spoken duration. Two sets of long- and short-duration words were selected, in each case maximizing duration differences but matching for frequency, familiarity, phonological similarity, and number of phonemes, and controlling for semantic associations. Serial recall measures were obtained using auditory and visual presentation and spoken and picture-pointing recall. In Experiments 1a and 1b, using the first set of items, long words were better recalled than short words. In Experiments 2a and 2b, using the second set of items, no difference was found between long and short disyllabic words. Experiment 3 confirmed the large advantage for short-duration words in the word set originally selected by Baddeley, Thomson, and Buchanan (1975). These findings suggest that there is no reliable advantage for short-duration disyllables in span tasks, and that previous accounts of a word-length effect in disyllables are based on accidental differences between list items. The failure to find an effect of word duration casts doubt on theories that propose that the capacity of memory span is determined by the duration of list items or the decay rate of phonological information in short-term memory.

  20. A phenomenological π-p scattering length from pionic hydrogen

    International Nuclear Information System (INIS)

    Ericson, T.E.O.; Loiseau, B.; Wycech, S.

    2004-01-01

    We derive a closed, model independent, expression for the electromagnetic correction factor to a phenomenological hadronic scattering length a h extracted from a hydrogenic atom. It is obtained in a non-relativistic approach and in the limit of a short ranged hadronic interaction to terms of order α 2 logα using an extended charge distribution. A hadronic πN scattering length a h π - p =0.0870(5)m π -1 is deduced leading to a πNN coupling constant from the GMO relation g c 2 /(4π)=14.04(17)

  1. Manipulating the stride length/stride velocity relationship of walking using a treadmill and rhythmic auditory cueing in non-disabled older individuals. A short-term feasibility study.

    Science.gov (United States)

    Eikema, D J A; Forrester, L W; Whitall, J

    2014-09-01

    One target for rehabilitating locomotor disorders in older adults is to increase mobility by improving walking velocity. Combining rhythmic auditory cueing (RAC) and treadmill training permits the study of the stride length/stride velocity ratio (SL/SV), often reduced in those with mobility deficits. We investigated the use of RAC to increase velocity by manipulating the SL/SV ratio in older adults. Nine participants (6 female; age: 61.1 ± 8.8 years) walked overground on a gait mat at preferred and fast speeds. After acclimatization to comfortable speed on a treadmill, participants adjusted their cadence to match the cue for 3 min at 115% of preferred speed by either (a) increasing stride length only or (b) increasing stride frequency only. Following training, participants walked across the gait mat at preferred velocity without, and then with, RAC. Group analysis determined no immediate overground velocity increase, but reintroducing RAC did produce an increase in velocity after both conditions. Group and single subject analysis determined that the SL/SV ratio changed in the intended direction only in the stride length condition. We conclude that RAC is a powerful organizer of gait parameters, evidenced by its induced after-effects following short duration training. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Short telomere length is associated with impaired cognitive performance in European ancestry cohorts

    NARCIS (Netherlands)

    Hägg, S.; Zhan, Y.; Karlsson, Robert; Gerritsen, L.; Ploner, A.; Lee, J.S.; Broer, L.; Deelen, J.; Marioni, R.E.; Wong, A.|info:eu-repo/dai/nl/29867291X; Lundquist, A.; Zhu, G.; Hansell, N.K.; Sillanpää, E.; Fedko, I O; Amin, N.A.; Beekman, Jeffrey M.; de Craen, A.J.M.; Degerman, S.; Harris, S.E.; Kan, K.-J.; Martin-Ruiz, C.M.; Montgomery, Grant W.; Adolfsson, A.N.; Reynolds, Chandra A.; Samani, Nilesh J; Suchiman, H.E.D.; Viljanen, A.; Von Zglinicki, T.; Wright, M J; Hottenga, J.J.; Boomsma, Dorret I; Rantanen, T.; Kaprio, J.A.; Nyholt, D.R.; Martin, N.G.|info:eu-repo/dai/nl/314123083; Nyberg, Lars; Adolfsson, R.; Kuh, D.; Starr, John M; Deary, Ian J; Slagboom, P Eline; Van Duijn, C.M.|info:eu-repo/dai/nl/068368232; Codd, V.; Pedersen, Nancy L.

    2017-01-01

    The association between telomere length (TL) dynamics on cognitive performance over the life-course is not well understood. This study meta-analyses observational and causal associations between TL and six cognitive traits, with stratifications on APOE genotype, in a Mendelian Randomization (MR)

  3. Aminophylline increases seizure length during electroconvulsive therapy.

    Science.gov (United States)

    Stern, L; Dannon, P N; Hirschmann, S; Schriber, S; Amytal, D; Dolberg, O T; Grunhaus, L

    1999-12-01

    Electroconvulsive therapy (ECT) is considered to be one of the most effective treatments for patients with major depression and persistent psychosis. Seizure characteristics probably determine the therapeutic effect of ECT; as a consequence, short seizures are accepted as one of the factors of poor outcome. During most ECT courses seizure threshold increases and seizure duration decreases. Methylxanthine preparations, caffeine, and theophylline have been used to prolong seizure duration. The use of aminophylline, more readily available than caffeine, has not been well documented. The objective of this study was to test the effects of aminophylline on seizure length. Fourteen drug-free patients with diagnoses of affective disorder or psychotic episode receiving ECT participated in this study. Seizure length was assessed clinically and per EEG. Statistical comparisons were done using paired t tests. A significant increase (p < 0.04) in seizure length was achieved and maintained on three subsequent treatments with aminophylline. No adverse events were noted from the addition of aminophylline.

  4. LPI Thresholds in Longer Scale Length Plasmas Driven by the Nike Laser*

    Science.gov (United States)

    Weaver, J.; Oh, J.; Phillips, L.; Afeyan, B.; Seely, J.; Kehne, D.; Brown, C.; Obenschain, S.; Serlin, V.; Schmitt, A. J.; Feldman, U.; Holland, G.; Lehmberg, R. H.; McLean, E.; Manka, C.

    2010-11-01

    The Krypton-Fluoride (KrF) laser is an attractive driver for inertial confinement fusion due to its short wavelength (248nm), large bandwidth (1-3 THz), and beam smoothing by induced spatial incoherence. Experiments with the Nike KrF laser have demonstrated intensity thresholds for laser plasma instabilities (LPI) higher than reported for other high power lasers operating at longer wavelengths (>=351 nm). The previous Nike experiments used short pulses (350 ps FWHM) and small spots (<260 μm FWHM) that created short density scale length plasmas (Ln˜50-70 μm) from planar CH targets and demonstrated the onset of two-plasmon decay (2φp) at laser intensities ˜2x10^15 W/cm^2. This talk will present an overview of the current campaign that uses longer pulses (0.5-4.0 ns) to achieve greater density scale lengths (Ln˜100-200 μm). X-rays, emission near ^1/2φo and ^3/2φo harmonics, and reflected laser light have been monitored for onset of 2φp. The longer density scale lengths will allow better comparison to results from other laser facilities. *Work supported by DoE/NNSA and ONR.

  5. Record length, mass, and clutch size in the nonindigenous Burmese Python, Python bivittatus Kuhl 1820 (Squamata: Pythonidae), in Florida

    Science.gov (United States)

    Krysko, Kenneth L.; Hart, Kristen M.; Smith, Brian J.; Selby, Thomas H.; Cherkiss, Michael S.; Coutu, Nicholas T.; Reichart, Rebecca M.; Nuñez, Leroy P.; Mazzotti, Frank J.; Snow, Ray W.

    2012-01-01

    The Burmese Python, Python bivittatus Kuhl 1820 (Squamata: Pythonidae), is indigenous to northern India,east to southern China, and south to Vietnam and a few islands in Indonesia (Barker and Barker 2008, Reed and Rodda 2009). This species has been introduced since at least 1979 in southern Florida, USA, where it likely began reproducing and became established during the 1980s (Meshaka et al. 2000, Snowet al. 2007b,Kraus 2009, Krysko et al. 2011, Willson et al. 2011). Python bivittatus has been documented in Florida consuming a variety of mammals and birds, and the American Alligator(Alligator mississippiensis) (Snowet al. 2007a, 2007b; Harvey et al. 2008; Rochford et al. 2010b; Holbrook and Chesnes 2011), many of which are protected species. Herein, we provide details on two of the largest known wild P. bivittatus in Florida to date, including current records on length,mass,clutch size, and diet.

  6. Word-Length Correlations and Memory in Large Texts: A Visibility Network Analysis

    Directory of Open Access Journals (Sweden)

    Lev Guzmán-Vargas

    2015-11-01

    Full Text Available We study the correlation properties of word lengths in large texts from 30 ebooks in the English language from the Gutenberg Project (www.gutenberg.org using the natural visibility graph method (NVG. NVG converts a time series into a graph and then analyzes its graph properties. First, the original sequence of words is transformed into a sequence of values containing the length of each word, and then, it is integrated. Next, we apply the NVG to the integrated word-length series and construct the network. We show that the degree distribution of that network follows a power law, P ( k ∼ k - γ , with two regimes, which are characterized by the exponents γ s ≈ 1 . 7 (at short degree scales and γ l ≈ 1 . 3 (at large degree scales. This suggests that word lengths are much more strongly correlated at large distances between words than at short distances between words. That finding is also supported by the detrended fluctuation analysis (DFA and recurrence time distribution. These results provide new information about the universal characteristics of the structure of written texts beyond that given by word frequencies.

  7. Biotic and Abiotic factors governing nestling-period length in the ovenbird (Seiurus aurocapilla)

    Science.gov (United States)

    Eric Stodola; David Buehler; Daniel Kim; Kathleen Franzreb; Daniel Linder

    2010-01-01

    In many songbirds, the nesting period for a breeding attempt is extremely short, often lasting only a few weeks. Breeding adults can shorten this period by decreasing the number of eggs laid or reducing the length of the nestling period. Nestling-period length has received little attention in the literature but could have profound effects on annual fecundity, because...

  8. Resorption of Lateral Incisors during Canine Eruption: Two Clinical Cases with Focus on Root Lengths and Heredity

    Directory of Open Access Journals (Sweden)

    Mostafa Zargham

    2016-01-01

    Full Text Available Introduction: It is well-known that pressure from orthodontic appliance can provoke root resorption in dentitions with short roots. The purpose of this case report is to demonstrate two clinical cases with focus on root length in dentitions exposed due to pressure from erupting teeth. This is a pilot study aimed to improve diagnostics for avoiding the resorption of lateral maxillary incisors by pressure from erupting canines. Case Report: The first reported case is of a girl who was 11 years and 7 months old when radiographs showed severe resorption of the lateral incisors, along with malformed central incisors and short roots. The intraoral photos demonstrated light crowding in the maxilla. The orthopantomogram of the girl’s mother demonstrated several short roots. The second reported case is of a girl who was 9 years and 5 months old when radiographs demonstrated nearly complete resorption on her lateral incisor roots, extremely short roots in the central incisors, and short roots. The intraoral photos demonstrated light crowding in the maxilla. The orthopantomogram of the girl’s mother demonstrated extremely short roots in general. Conclusion: This pilot study indicates that short root length in general and abnormal incisor morphology are phenotypic traits that were characteristic for both girls who presented with severe lateral incisor resorption due to erupting canines. Furthermore, short roots were also demonstrated in the mothers. Accordingly, short root length in general could be a phenotypic trait, which should be diagnosed early for preventing severe resorption of lateral incisors during canine eruption.

  9. Determining the influence of muscle operating length on muscle performance during frog swimming using a bio-robotic model

    International Nuclear Information System (INIS)

    Clemente, Christofer J; Richards, Christopher

    2012-01-01

    Frogs are capable of impressive feats of jumping and swimming. Recent work has shown that anuran hind limb muscles can operate at lengths longer than the ‘optimal length’. To address the implications of muscle operating length on muscle power output and swimming mechanics, we built a robotic frog hind limb model based upon Xenopus laevis. The model simulated the force–length and force–velocity properties of vertebrate muscle, within the skeletal environment. We tested three muscle starting lengths, representing long, optimal and short starting lengths. Increasing starting length increased maximum muscle power output by 27% from 98.1 W kg −1 when muscle begins shortening from the optimal length, to 125.1 W kg −1 when the muscle begins at longer initial lengths. Therefore, longer starting lengths generated greater hydrodynamic force for extended durations, enabling faster swimming speeds of the robotic frog. These swimming speeds increased from 0.15 m s −1 at short initial muscle lengths, to 0.39 m s −1 for the longest initial lengths. Longer starting lengths were able to increase power as the muscle's force–length curve was better synchronized with the muscle's activation profile. We further dissected the underlying components of muscle force, separating force–length versus force–velocity effects, showing a transition from force–length limitations to force–velocity limitations as starting length increased. (paper)

  10. Induced mutations of rice for short-culm selections in M{sub 2} generation

    Energy Technology Data Exchange (ETDEWEB)

    Ree, J H [Yungnam Crop Experiment Station, Office of Rural Development, Milyang (Korea, Republic of)

    1970-03-01

    Seeds of a leading rice variety Palkweng, japonica, were treated with X-rays and thermal neutrons to obtain mutations having short culm, earliness, resistance to lodging and blast disease, and a high yielding ability. 507 plants were selected for short-culm length; on the average they were also shorter in panicle length, lighter in weight of panicles, less in 100-grain weight and earlier in days to heading. There was no strict correlation between culm length and panicle length. Some plants had longer panicles in spite of a distinct reduction in culm length, but the number of panicles, weight of panicle and days to heading were positively correlated with culm length in the selected plants. The length of each internode from the base of the panicle down to the basal internode was gradually reduced. The lodging index was lower than that of the original variety, and culm length was positively correlated with lodging index. (author)

  11. A STUDY OF CORRELATION OF FOOT LENGTH AND GESTATIONAL MATURITY IN NEONATES

    Directory of Open Access Journals (Sweden)

    M. Bhuvaneswari

    2018-03-01

    Full Text Available BACKGROUND Gestational age estimation at birth can be done by clinical estimation through careful history of LMP, ultrasonic estimation of gestational age, date of first recorded foetal activity “quickening” first felt at approximately 16-18 weeks, Date of first recorded foetal heart sounds. MATERIALS AND METHODS A study sample of 800 live newborns were selected by simple random sampling technique born at GVR hospital and Government General Hospital, Kurnool from April 2015 to May 2016. Data was collected using standard proforma meeting the objectives of the study. a Gestational age assessment was done using modified Bellard’s score and b Foot length was measured using sliding calipers which is having an accuracy of a millimeter. Following instruments are used: 1 Sliding calipers for measuring foot length, 2 Flexible, non-stretchable measuring tape for head circumference, 3 Infantometer for measuring crown heel length, 4 Electronic weighing scale for measuring weight. RESULTS The foot length of preterm neonates ranged from 4.5-7.8 cm with the mean foot length of 6.1571 cm and 6.6964 cm for preterm SGA and AGA, respectively. The foot length of term neonates ranged from 5.4-8.7 cm with a mean foot length of 7.0471 cm, 7.5703 cm, 8.0391 cm for term SGA, AGA, LGA respectively. The foot length for post term neonates ranged from 6.7-8.8 cm, with a mean foot length of 7.5688 cm, 8.0170 cm and 8.2667 cm for post term SGA, AGA and LGA, respectively. This shows that foot length increases as the gestational age increases. CONCLUSION Foot length can be correlated significantly with the gestational age, birth weight, head circumference and crown heel length.

  12. The loss of short-term visual representations over time: decay or temporal distinctiveness?

    Science.gov (United States)

    Mercer, Tom

    2014-12-01

    There has been much recent interest in the loss of visual short-term memories over the passage of time. According to decay theory, visual representations are gradually forgotten as time passes, reflecting a slow and steady distortion of the memory trace. However, this is controversial and decay effects can be explained in other ways. The present experiment aimed to reexamine the maintenance and loss of visual information over the short term. Decay and temporal distinctiveness models were tested using a delayed discrimination task, in which participants compared complex and novel objects over unfilled retention intervals of variable length. Experiment 1 found no significant change in the accuracy of visual memory from 2 to 6 s, but the gap separating trials reliably influenced task performance. Experiment 2 found evidence for information loss at a 10-s retention interval, but temporally separating trials restored the fidelity of visual memory, possibly because temporally isolated representations are distinct from older memory traces. In conclusion, visual representations lose accuracy at some point after 6 s, but only within temporally crowded contexts. These findings highlight the importance of temporal distinctiveness within visual short-term memory. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  13. Short Review

    DEFF Research Database (Denmark)

    Lynnerup, Niels; Rühli, Frank

    2015-01-01

    modality in ancient mummy research. The aim of this short review is to address the advantages and pitfalls of this particular technique for such unique samples. We recommend that when results of X-ray examination of mummies are presented, the specific recording data should be listed, and any given finds...

  14. A phenomenological $\\pi^{-}p$ scattering length from pionic hydrogen

    CERN Document Server

    Ericson, Torleif Eric Oskar; Wycech, S

    2004-01-01

    We derive a closed, model independent, expression for the electromagnetic correction factor to a phenomenological hadronic scattering length a/sup h/ extracted from a hydrogenic atom. It is obtained in a non-relativistic approach and in the limit of a short ranged hadronic interaction to terms of order alpha /sup 2/ log alpha using an extended charge distribution. A hadronic pi N scattering length a/sub pi -p//sup h/ = 0.0870(5)m/sub pi //sup -1/ is deduced leading to a pi NN coupling constant from the GMO relation g/sub c //sup 2//(4 pi ) = 14.04(17). (28 refs).

  15. Longitudinal Diagnostics for Short Electron Beam Bunches

    Energy Technology Data Exchange (ETDEWEB)

    Loos, H.; /SLAC

    2010-06-11

    Single-pass free electron lasers require high peak currents from ultra-short electron bunches to reach saturation and an accurate measurement of bunch length and longitudinal bunch profile is necessary to control the bunch compression process from low to high beam energy. The various state-of-the-art diagnostics methods from ps to fs time scales using coherent radiation detection, RF deflection, and other techniques are presented. The use of linear accelerators as drivers for free electron lasers (FEL) and the advent of single-pass (SASE) FELs has driven the development of a wide range of diagnostic techniques for measuring the length and longitudinal distribution of short and ultra-short electron bunches. For SASE FELs the radiation power and the length of the undulator needed to achieve saturation depend strongly on the charge density of the electron beam. In the case of X-ray FELs, this requires the accelerator to produce ultra-high brightness beams with micron size transverse normalized emittances and peak currents of several kA through several stages of magnetic bunch compression. Different longitudinal diagnostics are employed to measure the peak current and bunch profile along these stages. The measurement techniques can be distinguished into different classes. Coherent methods detect the light emitted from the beam by some coherent radiation process (spectroscopic measurement), or directly measure the Coulomb field traveling with the beam (electro-optic). Phase space manipulation techniques map the time coordinate onto a transverse dimension and then use conventional transverse beam diagnostics (transverse deflector, rf zero-phasing). Further methods measure the profile or duration of an incoherent light pulse emitted by the bunch at wavelengths much shorted than the bunch length (streak camera, fluctuation technique) or modulate the electron beam at an optical wavelength and then generate a narrow bandwidth radiation pulse with the longitudinal profile of

  16. Performance Evaluation Of Furrow Lengths And Field Application Techniques

    Directory of Open Access Journals (Sweden)

    Issaka

    2015-08-01

    Full Text Available Abstract The study evaluated performance of furrow lengths and field application techniques. The experiment was conducted on 2000 m2 field at Bontanga irrigation scheme. Randomized Complete Block Design RCBD was used with three replicates. The replicates include Blocks A B and C of furrow lengths 100 m 75 m and 50 m respectively. Each replicate had surge cut-off cut-back and bunds treatments. Water was introduced into the furrows and the advance distances and time were measured. Results of the study showed that at Block A surge technique recorded the highest advance rate of 1.26 minm and opportunity time of 11 min whilst bunds recorded the lowest advance rate of 0.92 minm. Significant difference 3.32 pamp88050.05 occurred between treatment means of field application techniques at Block A 100 m. Significant difference 2.71 pamp88050.05 was also recorded between treatment means. At Block B 75 m there was significant difference 2.71 pamp88050.05 between treatment means. No significant difference 0.14 pamp88040.05 was observed among surge cut-back and bunds techniques. There was significant difference 2.60 pamp88050.05 between treatment means but no significant difference between cut-back and bunds techniques in Block C 50 m. Their performance was ranked in the order Surge Cut-back Cut-off Bunds for furrow lengths 100 m 75 m and 50 m respectively.

  17. Screening of SHOX gene sequence variants in Saudi Arabian children with idiopathic short stature.

    Science.gov (United States)

    Alharthi, Abdulla A; El-Hallous, Ehab I; Talaat, Iman M; Alghamdi, Hamed A; Almalki, Matar I; Gaber, Ahmed

    2017-10-01

    Short stature affects approximately 2%-3% of children, representing one of the most frequent disorders for which clinical attention is sought during childhood. Despite assumed genetic heterogeneity, mutations or deletions in the short stature homeobox-containing gene ( SHOX ) are frequently detected in subjects with short stature. Idiopathic short stature (ISS) refers to patients with short stature for various unknown reasons. The goal of this study was to screen all the exons of SHOX to identify related mutations. We screened all the exons of SHOX for mutations analysis in 105 ISS children patients (57 girls and 48 boys) living in Taif governorate, KSA using a direct DNA sequencing method. Height, arm span, and sitting height were recorded, and subischial leg length was calculated. A total of 30 of 105 ISS patients (28%) contained six polymorphic variants in exons 1, 2, 4, and 6. One mutation was found in the DNA domain binding region of exon 4. Three of these polymorphic variants were novel, while the others were reported previously. There were no significant differences in anthropometric measures in ISS patients with and without identifiable polymorphic variants in SHOX . In Saudi Arabia ISS patients, rather than SHOX , it is possible that new genes are involved in longitudinal growth. Additional molecular analysis is required to diagnose and understand the etiology of this disease.

  18. Length-dependent optical properties of single-walled carbon nanotube samples

    International Nuclear Information System (INIS)

    Naumov, Anton V.; Tsyboulski, Dmitri A.; Bachilo, Sergei M.; Weisman, R. Bruce

    2013-01-01

    Highlights: ► Length-independent absorption per atom in single-walled carbon nanotubes. ► Reduced fluorescence quantum yield for short nanotubes. ► Exciton quenching at nanotube ends, sidewall defects probably limits quantum yield. - Abstract: Contradictory findings have been reported on the length dependence of optical absorption cross sections and fluorescence quantum yields in single-walled carbon nanotubes (SWCNTs). To clarify these points, studies have been made on bulk SWCNT dispersions subjected to length fractionation by electrophoretic separation or by ultrasonication-induced scission. Fractions ranged from ca. 120 to 760 nm in mean length. Samples prepared by shear-assisted dispersion were subsequently shortened by ultrasonic processing. After accounting for processing-induced changes in the surfactant absorption background, SWCNT absorption was found constant within ±11% as average nanotube length changed by a factor of 3.8. This indicates that the absorption cross-section per carbon atom is not length dependent. By contrast, in length fractions prepared by both methods, the bulk fluorescence efficiency or average quantum yield increased with SWCNT average length and approached an apparent asymptotic limit near 1 μm. This result is interpreted as reflecting the combined contributions of exciton quenching by sidewall defects and by the ends of shorter nanotubes

  19. Year-to-year correlation, record length, and overconfidence in wind resource assessment

    Directory of Open Access Journals (Sweden)

    N. Bodini

    2016-08-01

    Full Text Available Interannual variability of wind speeds presents a fundamental source of uncertainty in preconstruction energy estimates. Our analysis of one of the longest and geographically most widespread extant sets of instrumental wind-speed observations (62-year records from 60 stations in Canada shows that deviations from mean resource levels persist over many decades, substantially increasing uncertainty. As a result of this persistence, the performance of each site's last 20 years diverges more widely than expected from the P50 level estimated from its first 42 years: half the sites have either fewer than 5 or more than 15 years exceeding the P50 estimate. In contrast to this 10-year-wide interquartile range, a 4-year-wide range (2.5 times narrower was found for "control" records where statistical independence was enforced by randomly permuting each station's historical values. Similarly, for sites with capacity factor of 0.35 and interannual variability of 6  %, one would expect 9 years in 10 to fall in the range 0.32–0.38; we find the actual 90  % range to be 0.27–0.43, or three times wider. The previously un-quantified effect of serial correlations favors a shift in resource-assessment thinking from a climatology-focused approach to a persistence-focused approach: for this data set, no improvement in P50 error is gained by using records longer than 4–5 years, and use of records longer than 20 years actually degrades accuracy.

  20. Minimal length uncertainty relation and ultraviolet regularization

    Science.gov (United States)

    Kempf, Achim; Mangano, Gianpiero

    1997-06-01

    Studies in string theory and quantum gravity suggest the existence of a finite lower limit Δx0 to the possible resolution of distances, at the latest on the scale of the Planck length of 10-35 m. Within the framework of the Euclidean path integral we explicitly show ultraviolet regularization in field theory through this short distance structure. Both rotation and translation invariance can be preserved. An example is studied in detail.

  1. Assessment of colorectal length using the electromagnetic capsule tracking system

    DEFF Research Database (Denmark)

    Mark, E B; Poulsen, J L; Haase, A M

    2017-01-01

    AIM: We aimed to determine colorectal length with the 3D-Transit system by describing a 'centerline' of capsule movement and compare it to known anatomy, as determined by magnetic resonance imaging (MRI). Further, we aimed to test the day-to-day variation of colorectal length assessed......: Computation of colorectal length from capsule passage was possible in 60 of the 67 3D-Transit recordings. Length of the colorectum measured with MRI and 3D-Transit was respectively 95 cm (75-153 cm) and 99 cm (77-147 cm), P = 0.15. Coefficient of variation (CV) between MRI and 3D-Transit was 7.8%. Apart from...... the cecum / ascending colon being 26% (P = 0.002) shorter on MRI, there were no other differences in total or segmental colorectal lengths between methods (all P > 0.05). Length of the colorectum measured with 3D-Transit on two consecutive days was 102 cm (73-119 cm) and 103 cm (75-123 cm), P = 0.67. CV...

  2. Short bunch wake potentials for a chain of TESLA cavities

    International Nuclear Information System (INIS)

    Novokhatski, Alexander; Mosnier, Alban

    2014-01-01

    The modification of wake fields from a single cavity to a quasi-periodic structure of cavities is of great concern, especially for applications using very short bunches. We extend our former study (Novokhatski, 1997 [1]). A strong modification of wake fields along a train of cavities was clearly found for bunch lengths lower than 1 mm. In particular, the wakes induced by the bunch, as it proceeds down the successive cavities, decrease in amplitude and become more linear around the bunch center, with a profile very close to the integral of the charge density. The loss factor, decreasing also with the number of cells, becomes independent of bunch length for very short bunches and tends asymptotically to a finite value. This nice behavior of wake fields for short bunches presents good opportunity for application of very short bunches in Linear Colliders and X-ray Free Electron Lasers

  3. A comparative study of the therapeutic effect between long and short intramedullary nails in the treatment of intertrochanteric femur fractures in the elderly.

    Science.gov (United States)

    Guo, Xue-Feng; Zhang, Ke-Ming; Fu, Hong-Bo; Cao, Wen; Dong, Qiang

    2015-01-01

    To compare the clinical effects of long vs. short intramedullary nails in the treatment of intertrochanteric fractures in old patients more than 65 years old. A retrospective analysis of 178 cases of intertrochanteric fractures of the femur (AO type A1 and A2) in the elderly was conducted from January 2008 to December 2013. There were 85 males (47.8%) and 93 females (52.2%) with the age of 65e89 (70.2±10.8) years. The patients were treated by closed reduction and long or short intramedullary nail (Gamma 3) fixation. The length of short nail was 180 mm and that for long nail was 320e360 mm. The general data of patients, operation time, intraoperative blood loss, length of hospital stay, preoperative hemoglobin level, blood transfusion rate, postoperative periprosthetic fractures, infections, complications, etc were carefully recorded. There were 76 cases (42.7%) in the long intramedullary nail group and 102 cases (57.3%) in the short nail group. All the cases were followed up for 12e48 (21.3±6.8) months, during which there were 21 deaths (11.8%), mean (13.8±6.9) months after operation. The intraoperative blood loss was (90.7±50.6) ml in short nail group, greatly less than that in long nail group (127.8±85.9) ml (p=0.004). The short nail group also had a significantly shorter operation time (43.5 min±12.3 min vs. 58.5 min±20.3 min, p=0.002) and lower rate of postoperative transfusion (42.3% vs. 56.7%, p=0.041). But the length of hospital stay showed no big differences. After operation, in each group there was 1 case of periprosthetic fracture with a total incidence of 1.1%, 1.3% in long nail group and 0.9% in short nail group. At the end of the follow-up, all patients achieved bony union. The average healing time of the long nail group was (6.5±3.1) months, and the short nail group was (6.8±3.7) months, revealing no significant differences (p=0.09). Postoperative complications showed no great differences either. Both the intramedullary long and short nail

  4. BAMBOO: Accelerating Closed Itemset Mining by Deeply Pushing the Length-Decreasing Support Constraint

    National Research Council Canada - National Science Library

    Wang, Jianyong; Karypis, George

    2003-01-01

    Previous study has shown that mining frequent patterns with length-decreasing support constraint is very helpful in removing some uninteresting patterns based on the observation that short patterns...

  5. Anatomic and functional leg-length inequality: A review and recommendation for clinical decision-making. Part I, anatomic leg-length inequality: prevalence, magnitude, effects and clinical significance

    Directory of Open Access Journals (Sweden)

    Knutson Gary A

    2005-07-01

    Full Text Available Abstract Background Leg-length inequality is most often divided into two groups: anatomic and functional. Part I of this review analyses data collected on anatomic leg-length inequality relative to prevalence, magnitude, effects and clinical significance. Part II examines the functional "short leg" including anatomic-functional relationships, and provides an outline for clinical decision-making. Methods Online database – Medline, CINAHL and MANTIS – and library searches for the time frame of 1970–2005 were done using the term "leg-length inequality". Results and Discussion Using data on leg-length inequality obtained by accurate and reliable x-ray methods, the prevalence of anatomic inequality was found to be 90%, the mean magnitude of anatomic inequality was 5.2 mm (SD 4.1. The evidence suggests that, for most people, anatomic leg-length inequality does not appear to be clinically significant until the magnitude reaches ~ 20 mm (~3/4". Conclusion Anatomic leg-length inequality is near universal, but the average magnitude is small and not likely to be clinically significant.

  6. Choosing a proper working length can improve the lifespan of locked plates. A biomechanical study.

    Science.gov (United States)

    Hoffmeier, Konrad L; Hofmann, Gunther O; Mückley, Thomas

    2011-05-01

    It is hypothesized that the working length influences the implants fatigue behavior. However, few studies addressing this issue came to contrary results. Therefore, we tested systematically the influence of working length and implant material on the plate's endurance. We used an artificial model providing the substantial angle and length conditions of a human femur. A fracture gap of 10mm was bridged with identical shaped plate implants made of stainless steel and grade-2 titanium. The fatigue strength was tested for a short, medium and long working length. Aiming at an implant failure within 80,000 loading cycles the upper load threshold was set to 265N for the titanium plates and to 420N for the steel plates. The lower load threshold was -20N for both plates. For the steel plates there was no correlation between fatigue strength and working length. The construct stiffness did not differ at short and medium working length and was reduced by 10% (P=0.047) at long working length. For the titanium plates the fatigue strength tends to increase with the working length but this correlation was not significant (τ=0.417, P=0.051). Further there was a negative correlation between working length and construct stiffness (τ=0.552; P=0.01). The working length has no appreciable effect on the endurance of the steel plates. Compared to the grade 2-titanium plates the stainless steel plates sustain a larger amount of cyclic load. However, for the titanium plates a larger working length tends to improve the endurance. Copyright © 2010 Elsevier Ltd. All rights reserved.

  7. Laser Texturing of Magnetic Recording Media Final Report CRADA No. TSV-1298-96

    Energy Technology Data Exchange (ETDEWEB)

    Hackel, L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Marshall, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-10-16

    The Commercial Laser Systems Group at LLNL developed a concept for patterning of computer magnetic recording discs. Magnetic recording media require texturing over areas designated for contact in order to minimize friction with data transducing heads. In fabricating a hard disk, an aluminum nickel-phosphorous substrate was polished to a specular finish then a mechanical means was used to roughen an annular area intended to be the head contact band. In a previous patent (US Patent 5,062,021) it was proposed that the focused output of a low power laser with short pulse length could be used to generate the textured pattern. However, the patterned area typically required 75,000 textured spots that needed to be rapidly (less than 10 seconds) printed with good uniformity. A means to achieve the accurate placement and uniform profile, as well as a meaningfully rapid process time, was not discussed in the referenced patent. The LLNL team devised a system that could rapidly and inexpensively accomplish the texturing.

  8. Short-term association between personal exposure to noise and heart rate variability: The RECORD MultiSensor Study.

    Science.gov (United States)

    El Aarbaoui, Tarik; Méline, Julie; Brondeel, Ruben; Chaix, Basile

    2017-12-01

    Studies revealed long-term associations between noise exposure and cardiovascular health, but the underlying short-term mechanisms remain uncertain. To explore the concomitant and lagged short-term associations between personal exposure to noise and heart rate variability (HRV) in a real life setting in the Île-de-France region. The RECORD MultiSensor Study collected between July 2014 and June 2015 noise and heart rate data for 75 participants, aged 34-74 years, in their living environments for 7 days using a personal dosimeter and electrocardiography (ECG) sensor on the chest. HRV parameters and noise levels were calculated for 5-min windows. Short-term relationships between noise level and log-transformed HRV parameters were assessed using mixed effects models with a random intercept for participants and a temporal autocorrelation structure, adjusted for heart rate, physical activity (accelerometry), and short-term trends. An increase by one dB(A) of A-weighted equivalent sound pressure level (Leq) was associated with a 0.97% concomitant increase of the Standard deviation of normal to normal intervals (SDNN) (95% CI: 0.92, 1.02), of 2.08% of the Low frequency band power (LF) (95% CI: 1.97, 2.18), of 1.30% of the High frequency band power (HF) (95% CI: 1.17, 1.43), and of 1.16% of the LF/HF ratio (95% CI: 1.10, 1.23). The analysis of lagged exposures to noise adjusted for the concomitant exposure illustrates the dynamic of recovery of the autonomic nervous system. Non-linear associations were documented with all HRV parameters with the exception of HF. Piecewise regression revealed that the association was almost 6 times stronger below than above 65 Leq dB(A) for the SDNN and LF/HF ratio. Personal noise exposure was found to be related to a concomitant increase of the overall HRV, with evidence of imbalance of the autonomic nervous system towards sympathetic activity, a pathway to increased cardiovascular morbidity and mortality. Copyright © 2017 Elsevier Ltd

  9. Inertial Effects on Finite Length Pipe Seismic Response

    Directory of Open Access Journals (Sweden)

    Virginia Corrado

    2012-01-01

    Full Text Available A seismic analysis for soil-pipe interaction which accounts for length and constraining conditions at the ends of a continuous pipe is developed. The Winkler model is used to schematize the soil-structure interaction. The approach is focused on axial strains, since bending strains in a buried pipe due to the wave propagation are typically a second-order effect. Unlike many works, the inertial terms are considered in solving equations. Accurate numerical simulations are carried out to show the influence of pipe length and constraint conditions on the pipe seismic strain. The obtained results are compared with results inferred from other models present in the literature. For free-end pipelines, inertial effects have significant influence only for short length. On the contrary, their influence is always important for pinned pipes. Numerical simulations show that a simple rigid model can be used for free-end pipes, whereas pinned pipes need more accurate models.

  10. High-throughput telomere length quantification by FISH and its application to human population studies.

    Science.gov (United States)

    Canela, Andrés; Vera, Elsa; Klatt, Peter; Blasco, María A

    2007-03-27

    A major limitation of studies of the relevance of telomere length to cancer and age-related diseases in human populations and to the development of telomere-based therapies has been the lack of suitable high-throughput (HT) assays to measure telomere length. We have developed an automated HT quantitative telomere FISH platform, HT quantitative FISH (Q-FISH), which allows the quantification of telomere length as well as percentage of short telomeres in large human sample sets. We show here that this technique provides the accuracy and sensitivity to uncover associations between telomere length and human disease.

  11. Cut-To-Length Harvesting of Short Rotation Eucalyptus at Simpson Tehama Fiber Farm

    Science.gov (United States)

    Bruce R. Hartsough; David J. Cooper

    1999-01-01

    A system consisting of a cut-to-length harvester, forwarder, mobile chipper and chip screen was tested in a 7-year-old plantation. Three levels of debarking effort by the harvester (minimal, partial and full), and two levels of screening (with and without) were evaluated. The harvester had the lowest production rate and highest cost of the system elements. Harvester...

  12. Idiopathic short stature

    Directory of Open Access Journals (Sweden)

    Vlaški Jovan

    2013-01-01

    Full Text Available Growth is a complex process and the basic characteristic of child- hood growth monitoring provides insight into the physiological and pathological events in the body. Statistically, the short stature means departure from the values of height for age and sex (in a particular environment, which is below -2 standard deviation score, or less than -2 standard deviation, i.e. below the third percentile. Advances in molecular genetics have contributed to the improvement of diagnostics in endocrinology. Analysis of patients’ genotypes should not be performed before taking a classical history, detailed clinical examination and appropriate tests. In patients with idiopathic short stature specific causes are excluded, such as growth hormone deficiency, Turner syndrome, short stature due to low birth weight, intrauterine growth retardation, small for gestational age, dysmorphology syndromes and chronic childhood diseases. The exclusion of abovementioned conditions leaves a large number of children with short stature whose etiology includes patients with genetic short stature or familial short stature and those who are low in relation to genetic potential, and who could also have some unrecognized endocrine defect. Idiopathic short stature represents a short stature of unknown cause of heterogeneous etiology, and is characterized by a normal response of growth hormone during stimulation tests (>10 ng/ml or 20 mJ/l, without other disorders, of normal body mass and length at birth. In idiopathic short stature standard deviation score rates <-2.25 (-2 to -3 or <1.2 percentile. These are also criteria for the initiation of growth hormone therapy. In children with short stature there is also the presence of psychological and social suffering. Goals of treatment with growth hormone involve achieving normal height and normal growth rate during childhood.

  13. A New Species and a New Record of the Diastylidae (Crustacea: Cumacea from Korea

    Directory of Open Access Journals (Sweden)

    Chang-Mok Lee

    2012-04-01

    Full Text Available In this study, a new species, Dimorphostylis breviplicata n. sp. is described and illustrated on the basis of specimens collected from the shallow Korean waters. This new species is similar to Dimorphostylis brevicaudata (Zimmer, 1903, Dimorphostylis acroplicata Harada, 1960 and Dimorphostylis valida Gamo, 1962 in that the carapace has three pairs of oblique ridges on the surface. However, the new species is distinguished by the combination of the following features: the middle oblique ridge is short and not joined to the other oblique ridges; the transverse ridge is absent on the frontal lobe; the dorso-median process on the pereonite 5 is only barely visible; the male telson has no short stout seta on the both lateral margins; the length ratio of the first to remaining articles combined on the male uropod is 1 : 0.7. A key to the Korean Dimorphostylis species is provided. Also, Diastylis alaskensis Calman, 1912 is redescribed as a new recorded species of the Korean fauna.

  14. [Length of lactational amenorrhea in an urban population of Temuco, Chile].

    Science.gov (United States)

    Valdés, Patricio; Sierralta, Pablo; Ossa, Ximena; Barría, Angélica

    2002-01-01

    Studies done in Santiago, Chile show that menses return before the sixth month of puerperium in 50% of lactating women, even in those that continue with exclusive breast feeding. To study the length of lactational amenorrhea in a group of women living in Southern Chile. One hundred fourteen women giving exclusive breast feeding, were followed from the third postpartum month, to determine the length of lactational amenorrhea. Its relationship with general characteristics of the mothers and children and breast feeding pattern was also studied. Sixty six women (58%) recovered their menses before the 6th postpartum month and their length of lactational amenorrhea was 101 +/- 5 days. In the rest of the sample, the length was 277 +/- 10 days. No differences in characteristics of the mothers and children or breast feeding pattern, were observed between these two groups. A short lactational amenorrhea is common in the Chilean population. Clinical characteristics or pattern of breast feeding do not explain the length of LA in this population.

  15. Coffee-Ring Defined Short Channels for Inkjet-Printed Metal Oxide Thin-Film Transistors.

    Science.gov (United States)

    Li, Yuzhi; Lan, Linfeng; Xiao, Peng; Sun, Sheng; Lin, Zhenguo; Song, Wei; Song, Erlong; Gao, Peixiong; Wu, Weijing; Peng, Junbiao

    2016-08-03

    Short-channel electronic devices several micrometers in length are difficult to implement by direct inkjet printing due to the limitation of position accuracy of the common inkjet printer system and the spread of functional ink on substrates. In this report, metal oxide thin-film transistors (TFTs) with channel lengths of 3.5 ± 0.7 μm were successfully fabricated with a common inkjet printer without any photolithography steps. Hydrophobic CYTOP coffee stripes, made by inkjet-printing and plasma-treating processes, were utilized to define the channel area of TFTs with channel lengths as short as ∼3.5 μm by dewetting the inks of the source/drain (S/D) precursors. Furthermore, by introduction of an ultrathin layer of PVA to modify the S/D surfaces, the spreading of precursor ink of the InOx semiconductor layer was well-controlled. The inkjet-printed short-channel TFTs exhibited a maximum mobility of 4.9 cm(2) V(-1) s(-1) and an on/off ratio of larger than 10(9). This approach of fabricating short-channel TFTs by inkjet printing will promote the large-area fabrication of short-channel TFTs in a cost-effective manner.

  16. Pointing towards visuospatial patterns in short-term memory: differential effects on familiarity- and recollection-based judgments.

    Science.gov (United States)

    Rossi-Arnaud, Clelia; Spataro, Pietro; Marques, Valeria R S; Longobardi, Emiddia

    2015-03-01

    Previous studies have indicated that pointing toward to-be-remembered visuospatial patterns enhances short-term memory (STM) when the presentation of pointing and no-pointing trials is mixed (Chum et al., 2007; Dodd & Shumborski, 2009; Rossi-Arnaud et al., 2012). By contrast, when presentation is blocked, pointing has inhibitory effects on memory (Dodd & Shumborski, 2009; Rossi-Arnaud et al., 2012). In the present study, we demonstrated that pointing has different effects on short-term recollection- and familiarity-based judgments, depending on the length of the visuospatial patterns (5- vs. 7-item arrays) and the interval between the encoding and test phases (2 vs. 5 s). More specifically, pointing decreased the accuracy of recollection-based judgments for 5-item arrays, but not for 7-item arrays (this negative effect did not interact with interval length). In contrast, pointing facilitated familiarity-based judgments when the interval between the study and test phases was 5 s, but not when it was 2 s (this positive effect did not interact with pattern length). We proposed that the negative effects might be accounted for by the simultaneous recruitment of attention resources in the planning and execution of pointing movements. As a consequence, executive resources are diverted from the primary memory task, resulting in a less efficient use of attention-demanding retrieval strategies, like chunking. By contrast, the positive effects on familiarity judgments might reflect the unitization of the to-be-remembered items into a single shape. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  17. Sorting signed permutations by short operations.

    Science.gov (United States)

    Galvão, Gustavo Rodrigues; Lee, Orlando; Dias, Zanoni

    2015-01-01

    During evolution, global mutations may alter the order and the orientation of the genes in a genome. Such mutations are referred to as rearrangement events, or simply operations. In unichromosomal genomes, the most common operations are reversals, which are responsible for reversing the order and orientation of a sequence of genes, and transpositions, which are responsible for switching the location of two contiguous portions of a genome. The problem of computing the minimum sequence of operations that transforms one genome into another - which is equivalent to the problem of sorting a permutation into the identity permutation - is a well-studied problem that finds application in comparative genomics. There are a number of works concerning this problem in the literature, but they generally do not take into account the length of the operations (i.e. the number of genes affected by the operations). Since it has been observed that short operations are prevalent in the evolution of some species, algorithms that efficiently solve this problem in the special case of short operations are of interest. In this paper, we investigate the problem of sorting a signed permutation by short operations. More precisely, we study four flavors of this problem: (i) the problem of sorting a signed permutation by reversals of length at most 2; (ii) the problem of sorting a signed permutation by reversals of length at most 3; (iii) the problem of sorting a signed permutation by reversals and transpositions of length at most 2; and (iv) the problem of sorting a signed permutation by reversals and transpositions of length at most 3. We present polynomial-time solutions for problems (i) and (iii), a 5-approximation for problem (ii), and a 3-approximation for problem (iv). Moreover, we show that the expected approximation ratio of the 5-approximation algorithm is not greater than 3 for random signed permutations with more than 12 elements. Finally, we present experimental results that show

  18. A phenomenological {pi}{sup -}p scattering length from pionic hydrogen

    Energy Technology Data Exchange (ETDEWEB)

    Ericson, T.E.O.; Loiseau, B.; Wycech, S

    2004-07-29

    We derive a closed, model independent, expression for the electromagnetic correction factor to a phenomenological hadronic scattering length a{sup h} extracted from a hydrogenic atom. It is obtained in a non-relativistic approach and in the limit of a short ranged hadronic interaction to terms of order {alpha}{sup 2}log{alpha} using an extended charge distribution. A hadronic {pi}N scattering length a{sup h}{sub {pi}{sup -}}{sub p}=0.0870(5)m{sub {pi}}{sup -1} is deduced leading to a {pi}NN coupling constant from the GMO relation g{sub c}{sup 2}/(4{pi})=14.04(17)

  19. Fundamental length and relativistic length

    International Nuclear Information System (INIS)

    Strel'tsov, V.N.

    1988-01-01

    It si noted that the introduction of fundamental length contradicts the conventional representations concerning the contraction of the longitudinal size of fast-moving objects. The use of the concept of relativistic length and the following ''elongation formula'' permits one to solve this problem

  20. Influence of channel length and layout on TID for 0.18 μm NMOS transistors

    International Nuclear Information System (INIS)

    Wu Xue; Wang Xin; Xi Shanbin; Lu Wu; Guo Qi; He Chengfa; Li Yudong; Sun Jing; Wen Lin

    2013-01-01

    Different channel lengths and layouts on 0.18 μm NMOS transistors are designed for investigating the dependence of short channel effects (SCEs) on the width of shallow trench isolation (STI) devices and designing in radiation hardness. Results show that, prior to irradiation, the devices exhibited near-ideal I-V characteristics, with no significant SCEs. Following irradiation, no noticeable shift of threshold voltage is observed, radiation-induced edge-leakage current, however, exhibits significant sensitivity on TID. Moreover, radiation-enhanced drain induced barrier lowering (DIBL) and channel length modulation (CLM) effects are observed on short-channel NMOS transistors. Comparing to stripe-gate layout, enclosed-gate layout has excellent radiation tolerance. (authors)

  1. Field Optimization for short Period Undulators

    CERN Document Server

    Peiffer, P; Rossmanith, R; Schoerling, D

    2011-01-01

    Undulators dedicated to low energy electron beams, like Laser Wakefield Accelerators, require very short period lengths to achieve X-ray emission. However, at these short period length (LambdaU ~ 5 mm) it becomes difficult to reach magnetic field amplitudes that lead to a K parameter of >1, which is generally desired. Room temperature permanent magnets and even superconductive undulators using Nb-Ti as conductor material have proven insufficient to achieve the desired field amplitudes. The superconductor Nb$_{3}$Sn has the theoretical potential to achieve the desired fields. However, up to now it is limited by several technological challenges to much lower field values than theoretically predicted. An alternative idea for higher fields is to manufacture the poles of the undulator body from Holmium instead of iron or to use Nb-Ti wires with a higher superconductor/copper ratio. The advantages and challenges of the different options are compared in this contribution.

  2. Estimating trends in the global mean temperature record

    Science.gov (United States)

    Poppick, Andrew; Moyer, Elisabeth J.; Stein, Michael L.

    2017-06-01

    Given uncertainties in physical theory and numerical climate simulations, the historical temperature record is often used as a source of empirical information about climate change. Many historical trend analyses appear to de-emphasize physical and statistical assumptions: examples include regression models that treat time rather than radiative forcing as the relevant covariate, and time series methods that account for internal variability in nonparametric rather than parametric ways. However, given a limited data record and the presence of internal variability, estimating radiatively forced temperature trends in the historical record necessarily requires some assumptions. Ostensibly empirical methods can also involve an inherent conflict in assumptions: they require data records that are short enough for naive trend models to be applicable, but long enough for long-timescale internal variability to be accounted for. In the context of global mean temperatures, empirical methods that appear to de-emphasize assumptions can therefore produce misleading inferences, because the trend over the twentieth century is complex and the scale of temporal correlation is long relative to the length of the data record. We illustrate here how a simple but physically motivated trend model can provide better-fitting and more broadly applicable trend estimates and can allow for a wider array of questions to be addressed. In particular, the model allows one to distinguish, within a single statistical framework, between uncertainties in the shorter-term vs. longer-term response to radiative forcing, with implications not only on historical trends but also on uncertainties in future projections. We also investigate the consequence on inferred uncertainties of the choice of a statistical description of internal variability. While nonparametric methods may seem to avoid making explicit assumptions, we demonstrate how even misspecified parametric statistical methods, if attuned to the

  3. Word skipping: effects of word length, predictability, spelling and reading skill.

    Science.gov (United States)

    Slattery, Timothy J; Yates, Mark

    2017-08-31

    Readers eyes often skip over words as they read. Skipping rates are largely determined by word length; short words are skipped more than long words. However, the predictability of a word in context also impacts skipping rates. Rayner, Slattery, Drieghe and Liversedge (2011) reported an effect of predictability on word skipping for even long words (10-13 characters) that extend beyond the word identification span. Recent research suggests that better readers and spellers have an enhanced perceptual span (Veldre & Andrews, 2014). We explored whether reading and spelling skill interact with word length and predictability to impact word skipping rates in a large sample (N=92) of average and poor adult readers. Participants read the items from Rayner et al. (2011) while their eye movements were recorded. Spelling skill (zSpell) was assessed using the dictation and recognition tasks developed by Sally Andrews and colleagues. Reading skill (zRead) was assessed from reading speed (words per minute) and accuracy of three 120 word passages each with 10 comprehension questions. We fit linear mixed models to the target gaze duration data and generalized linear mixed models to the target word skipping data. Target word gaze durations were significantly predicted by zRead while, the skipping likelihoods were significantly predicted by zSpell. Additionally, for gaze durations, zRead significantly interacted with word predictability as better readers relied less on context to support word processing. These effects are discussed in relation to the lexical quality hypothesis and eye movement models of reading.

  4. Determination of Onramp Weaving Length for Resolving Merging Dilemma

    Directory of Open Access Journals (Sweden)

    Chiu Liu

    2012-03-01

    Full Text Available It is physically known that onramp merging may turn out to be difficult if the onramp (weaving/merging length is too short because a driver under certain driving circumstances may find that either merging ahead or merging behind a neighboring vehicle on the adjacent highway lane cannot be completed. Various existing guidelines or design manuals provide no clear physical understanding and explanations to the design onramp weaving length but often based on evolved empirical experiences. By integrating human factors, vehicle dynamic characteristics, roadway surface condition, and the onramp weaving design into a single unified analytic framework, the onramp length required for a driver to merge into the highway traffic successfully is determined exactly with formulas and physical solutions to avoid the merging dilemma and enhance driving safety at highway interchanges. The design onramp weaving length is examined and evaluated with various foreseeable merging scenarios and physical examples. This analytic framework sheds light on the understanding of the onramp weaving the first time strictly on a physical human-vehicle-roadway interaction setting. Practitioners can easily apply these user friendly formulae and equations derived from the unified framework to calculate the onramp weaving length to resolve the merging dilemma and enhance driving safety for any highway interchanges.

  5. Administrative license suspension: Does length of suspension matter?

    Science.gov (United States)

    Fell, James C; Scherer, Michael

    2017-08-18

    Administrative license revocation (ALR) laws, which provide that the license of a driver with a blood alcohol concentration at or over the illegal limit is subject to an immediate suspension by the state department of motor vehicles, are an example of a traffic law in which the sanction rapidly follows the offense. The power of ALR laws has been attributed to how swiftly the sanction is applied, but does the length of suspension matter? Our objectives were to (a) determine the relationship of the ALR suspension length to the prevalence of drinking drivers relative to sober drivers in fatal crashes and (b) estimate the extent to which the relationship is associated to the general deterrent effect compared to the specific deterrent effect of the law. Data comparing the impact of ALR law implementation and ALR law suspension periods were analyzed using structural equation modeling techniques on the ratio of drinking drivers to nondrinking drivers in fatal crashes from the Fatality Analysis Reporting System (FARS). States with an ALR law with a short suspension period (1-30 days) had a significantly lower drinking driver ratio than states with no ALR law. States with a suspension period of 91-180 days had significantly lower ratios than states with shorter suspension periods, while the three states with suspension lengths of 181 days or longer had significantly lower ratios than states with shorter suspension periods. The implementation of any ALR law was associated with a 13.1% decrease in the drinking/nondrinking driver fatal crash ratio but only a 1.8% decrease in the intoxicated/nonintoxicated fatal crash ratio. The ALR laws and suspension lengths had a significant general deterrent effect, but no specific deterrent effect. States might want to keep (or adopt) ALR laws for their general deterrent effects and pursue alternatives for specific deterrent effects. States with short ALR suspension periods should consider lengthening them to 91 days or longer.

  6. Optimum Discharge Burnup and Cycle Length for PWRs

    International Nuclear Information System (INIS)

    Secker, Jeffrey R.; Johansen, Baard J.; Stucker, David L.; Ozer, Odelli; Ivanov, Kostadin; Yilmaz, Serkan; Young, E.H.

    2005-01-01

    This paper discusses the results of a pressurized water reactor fuel management study determining the optimum discharge burnup and cycle length. A comprehensive study was performed considering 12-, 18-, and 24-month fuel cycles over a wide range of discharge burnups. A neutronic study was performed followed by an economic evaluation. The first phase of the study limited the fuel enrichments used in the study to 235 U consistent with constraints today. The second phase extended the range of discharge burnups for 18-month cycles by using fuel enriched in excess of 5 wt%. The neutronic study used state-of-the-art reactor physics methods to accurately determine enrichment requirements. Energy requirements were consistent with today's high capacity factors (>98%) and short (15-day) refueling outages. The economic evaluation method considers various component costs including uranium, conversion, enrichment, fabrication and spent-fuel storage costs as well as the effect of discounting of the revenue stream. The resulting fuel cycle costs as a function of cycle length and discharge burnup are presented and discussed. Fuel costs decline with increasing discharge burnup for all cycle lengths up to the maximum discharge burnup considered. The choice of optimum cycle length depends on assumptions for outage costs

  7. Accuracy of self-reported length of coma and posttraumatic amnesia in persons with medically verified traumatic brain injury.

    Science.gov (United States)

    Sherer, Mark; Sander, Angelle M; Maestas, Kacey Little; Pastorek, Nicholas J; Nick, Todd G; Li, Jingyun

    2015-04-01

    To determine the accuracy of self-reported length of coma and posttraumatic amnesia (PTA) in persons with medically verified traumatic brain injury (TBI) and to investigate factors that affect self-report of length of coma and PTA duration. Prospective cohort study. Specialized rehabilitation center with inpatient and outpatient programs. Persons (N=242) with medically verified TBI who were identified from a registry of persons who had previously participated in TBI-related research. Not applicable. Self-reported length of coma and self-reported PTA duration. Review of medical records revealed that the mean medically documented length of coma and PTA duration was 6.9±12 and 19.2±22 days, respectively, and the mean self-reported length of coma and PTA duration was 16.7±22 and 106±194 days, respectively. The average discrepancy between self-report and medical record for length of coma and PTA duration was 8.2±21 and 64±176 days, respectively. Multivariable regression models revealed that time since injury, performance on cognitive tests, and medical record values were associated with self-reported values for both length of coma and PTA duration. In this investigation, persons with medically verified TBI showed poor accuracy in their self-report of length of coma and PTA duration. Discrepancies were large enough to affect injury severity classification. Caution should be exercised when considering self-report of length of coma and PTA duration. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  8. Estimation and calibration of the water isotope differential diffusion length in ice core records

    NARCIS (Netherlands)

    van der Wel, G.; Fischer, H.; Oerter, H.; Meyer, H.; Meijer, H. A. J.

    2015-01-01

    Palaeoclimatic information can be retrieved from the diffusion of the stable water isotope signal during firnification of snow. The diffusion length, a measure for the amount of diffusion a layer has experienced, depends on the firn temperature and the accumulation rate. We show that the estimation

  9. Visual short-term store can compensate for a defective phonological short-term store in patients with apraxia of speech.

    Science.gov (United States)

    Silveri, Maria Caterina; Baldonero, Eleonora

    2013-11-01

    The aim of the study was to investigate whether, within the phonological short-term memory (STM) system, speech articulation disorders primarily due to cortical damage are associated with deficits in the phonological recoding of visual-verbal material, and whether the visual short-term store (STS) can compensate for inefficient access to the phonological STS, as suggested in previous reports. Two patients (AE and TM) with apraxia of speech due to atrophic cerebral damage were administered a battery of tasks devised to explore the organization of the phonological STM. AE's span was normal and TM's span was markedly reduced. Phonological similarity and word-length effects: Both patients showed the effects in visual presentation; the effect was less evident in verbal presentation. This suggests a phonological STS disorder and preserved rehearsal/phonological recoding, consistently with involvement of the left parietal regions, which was documented by the MRI in both patients. Unexpectedly, TM had a longer span for similar than for dissimilar words in visually presented stimuli. Silent phonology (on written material): At variance with controls, stress assignment improved during unattended speech both in AE and TM, while in both patients and controls a detrimental effect of unattended speech was documented in the initial sound task. To account for this unusual pattern of results, we hypothesized that whenever possible, AE and TM adopt the strategy that takes advantage of the visual STM store to compensate for a defective phonological STS. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  10. The processing of spatial information in short-term memory: insights from eye tracking the path length effect.

    Science.gov (United States)

    Guérard, Katherine; Tremblay, Sébastien; Saint-Aubin, Jean

    2009-10-01

    Serial memory for spatial locations increases as the distance between successive stimuli locations decreases. This effect, known as the path length effect [Parmentier, F. B. R., Elford, G., & Maybery, M. T. (2005). Transitional information in spatial serial memory: Path characteristics affect recall performance. Journal of Experimental Psychology: Learning, Memory & Cognition, 31, 412-427], was investigated in a systematic manner using eye tracking and interference procedures to explore the mechanisms responsible for the processing of spatial information. In Experiment 1, eye movements were monitored during a spatial serial recall task--in which the participants have to remember the location of spatially and temporally separated dots on the screen. In the experimental conditions, eye movements were suppressed by requiring participants to incessantly move their eyes between irrelevant locations. Ocular suppression abolished the path length effect whether eye movements were prevented during item presentation or during a 7s retention interval. In Experiment 2, articulatory suppression was combined with a spatial serial recall task. Although articulatory suppression impaired performance, it did not alter the path length effect. Our results suggest that rehearsal plays a key role in serial memory for spatial information, though the effect of path length seems to involve other processes located at encoding, such as the time spent fixating each location and perceptual organization.

  11. Exploiting publicly available biological and biochemical information for the discovery of novel short linear motifs.

    KAUST Repository

    Sayadi, Ahmed; Briganti, Leonardo; Tramontano, Anna; Via, Allegra

    2011-01-01

    The function of proteins is often mediated by short linear segments of their amino acid sequence, called Short Linear Motifs or SLiMs, the identification of which can provide important information about a protein function. However, the short length

  12. Depressive and anxiety disorders and short leukocyte telomere length: mediating effects of metabolic stress and lifestyle factors.

    Science.gov (United States)

    Révész, D; Verhoeven, J E; Milaneschi, Y; Penninx, B W J H

    2016-08-01

    Depressive and anxiety disorders are associated with shorter leukocyte telomere length (LTL), an indicator of cellular aging. It is, however, unknown which pathways underlie this association. This study examined the extent to which lifestyle factors and physiological changes such as inflammatory or metabolic alterations mediate the relationship. We applied mediation analysis techniques to data from 2750 participants of the Netherlands Study of Depression and Anxiety. LTL was assessed using quantitative polymerase chain reaction. Independent variables were current depressive (30-item Inventory of Depressive Symptoms - Self Report) and anxiety (21-item Beck's Anxiety Inventory) symptoms and presence of a depressive or anxiety disorder diagnosis based on DSM-IV; mediator variables included physiological stress systems, metabolic syndrome components and lifestyle factors. Short LTL was associated with higher symptom severity (B = -2.4, p = 0.002) and current psychiatric diagnosis (B = -63.3, p = 0.024). C-reactive protein, interleukin-6, waist circumference, triglycerides, high-density lipoprotein cholesterol and cigarette smoking were significant mediators in the relationship between psychopathology and LTL. When all significant mediators were included in one model, the effect sizes of the relationships between LTL and symptom severity and current diagnosis were reduced by 36.7 and 32.7%, respectively, and the remaining direct effects were no longer significant. Pro-inflammatory cytokines, metabolic alterations and cigarette smoking are important mediators of the association between depressive and anxiety disorders and LTL. This calls for future research on intervention programs that take into account lifestyle changes in mental health care settings.

  13. Short-Term Study Abroad: Culture and the Path of Least Resistance

    Science.gov (United States)

    Lemmons, Kelly

    2015-01-01

    American universities are decreasing the length of study abroad programs in an effort to send more students abroad. Recent publications find that "short-term" programs struggle to increase participants' cultural understanding. However, these research findings fail to offer an explanation as to why shorter programs are falling short. This…

  14. Simulation of a short-cable Q-meter for measuring the deuteron target polarization

    International Nuclear Information System (INIS)

    Karnaukhov, I.M.; Lukhanin, A.A.; Telegin, Yu.N.; Trotsenko, V.I.; Chechetenko, V.F.

    1984-01-01

    Simulation of Q-meter with a phase automatic-frequency control of a reception circuit is carried out in the paper. Effect of circuit parameters and connecting cable on Q-meter sensitivity and magnitude of distortions of recorded signal is studied. It is shown that usage of the cable with a length of lambda/12-lambda/10 instead of traditional semiwave one enables to increase essentially the circuit sensitivity at the same distortion rate. Errors conditioned by distortions of the deuteron magnetic resonance (DMR) signal forms in the reception circuit, which can effect essertially on accuracy of deuteron polarization detection by the method of DMR spectrum decomposition, are discussed. It is shown that in the case of utilization of a short cable the polarization error due to spectrum distortions does not exceed 4...5%

  15. The distribution pattern of critically short telomeres in human osteoarthritic knees

    DEFF Research Database (Denmark)

    Harbo, Maria; Bendix, Laila; Bay-Jensen, Anne Christine

    2012-01-01

    ABSTRACT: INTRODUCTION: Telomere shortening is associated with a number of common age-related diseases. A role of telomere shortening in osteoarthritis (OA) has been suggested, mainly based on the assessment of mean telomere length in ex vivo expanded chondrocytes. We addressed this role directly...... in vivo by using a newly developed assay, which measures specifically the load of ultra-short single telomeres (below 1,500 base pairs), that is, the telomere subpopulation believed to promote cellular senescence. METHODS: Samples were obtained from human OA knees at two distances from the central lesion...... site. Each sample was split into three: one was used for quantification of ultra-short single telomeres through the Universal single telomere length assay (STELA), one for histological Mankin grading of OA, and one for mean telomere length measurement through quantitative fluorescence in situ...

  16. Respiratory symptoms are more common among short sleepers independent of obesity

    DEFF Research Database (Denmark)

    Björnsdóttir, Erla; Janson, Christer; Lindberg, Eva

    2017-01-01

    , marital status, exercise and smoking. Excluding BMI from the model covariates did not affect the results. Short sleep was related to 11 out of 16 respiratory and nasal symptoms among subjects with BMI ≥30 and 9 out of 16 symptoms among subjects with BMI sleep......INTRODUCTION: Sleep length has been associated with obesity and various adverse health outcomes. The possible association of sleep length and respiratory symptoms has not been previously described. The aim of this study was to investigate the association between sleep length and respiratory...... Health Survey III. The mean±SD age was 54.2±7.1 (age range 39-67 years). Information was collected on general and respiratory health and sleep characteristics. RESULTS: The mean reported nighttime sleep duration was 6.9±1.0 hours. Short sleepers (

  17. Short-length and high-density TiO2 nanorod arrays for the efficient charge separation interface in perovskite solar cells

    International Nuclear Information System (INIS)

    Xiao, Guannan; Shi, Chengwu; Zhang, Zhengguo; Li, Nannan; Li, Long

    2017-01-01

    O 2 nanorod arrays. • Preparation of over-500 nm-thickness CH 3 NH 3 PbI 3−x Br x absorber layer. • Combination of short-length TiO 2 nanorod array and high-thickness perovskite layer. • The best and average PCE with TiO 2 array of 15.93% and 13.41±2.52% at 50–54% RH.

  18. Short wavelength lateral variability of lithospheric mantle beneath the Middle Atlas (Morocco) as recorded by mantle xenoliths

    Science.gov (United States)

    El Messbahi, Hicham; Bodinier, Jean-Louis; Vauchez, Alain; Dautria, Jean-Marie; Ouali, Houssa; Garrido, Carlos J.

    2015-05-01

    The Middle Atlas is a region where xenolith-bearing volcanism roughly coincides with the maximum of lithospheric thinning beneath continental Morocco. It is therefore a key area to study the mechanisms of lithospheric thinning and constrain the component of mantle buoyancy that is required to explain the Moroccan topography. Samples from the two main xenolith localities, the Bou Ibalghatene and Tafraoute maars, have been investigated for their mineralogy, microstructures, crystallographic preferred orientation, and whole-rock and mineral compositions. While Bou Ibalghatene belongs to the main Middle Atlas volcanic field, in the 'tabular' Middle Atlas, Tafraoute is situated about 45 km away, on the North Middle Atlas Fault that separates the 'folded' Middle Atlas, to the South-East, from the 'tabular' Middle Atlas, to the North-West. Both xenolith suites record infiltration of sub-lithospheric melts that are akin to the Middle Atlas volcanism but were differentiated to variable degrees as a result of interactions with lithospheric mantle. However, while the Bou Ibalghatene mantle was densely traversed by high melt fractions, mostly focused in melt conduits, the Tafraoute suite records heterogeneous infiltration of smaller melt fractions that migrated diffusively, by intergranular porous flow. As a consequence the lithospheric mantle beneath Bou Ibalghaten was strongly modified by melt-rock interactions in the Cenozoic whereas the Tafraoute mantle preserves the record of extensional lithospheric thinning, most likely related to Mesozoic rifting. The two xenolith suites illustrate distinct mechanisms of lithospheric thinning: extensional thinning in Tafraoute, where hydrous incongruent melting triggered by decompression probably played a key role in favouring strain localisation, vs. thermal erosion in Bou Ibalghatene, favoured and guided by a dense network of melt conduits. Our results lend support to the suggestion that lithospheric thinning beneath the Atlas

  19. Determination of the negatively charged pion-proton scattering length from pionic hydrogen

    CERN Document Server

    Ericson, Torleif Eric Oskar; Wycech, S

    2003-01-01

    We derive a closed, model independent, expression for the electromagnetic correction factor to the hadronic scattering length extracted from a hydrogenic atom with an extended charge and in the limit of a short ranged hadronic interaction to terms of order ((alpha)**2)(log(alpha)) in the limit of a non-relativistic approach. A hadronic negatively charged pion-proton scattering length of 0.0870(5), in units of inverse charged pion-mass, is deduced, leading to a pion-nucleon coupling constant from the GMO relation equals to 14.00(19).

  20. A phenomenological determination of the pion-nucleon scattering lengths from pionic hydrogen

    CERN Document Server

    Ericson, Torleif Eric Oskar; Wycech, S

    2005-01-01

    A model independent expression for the electromagnetic corrections to a phenomenological hadronic pion-nucleon scattering length, extracted from pionic hydrogen, is obtained. In a non-relativistic approach and using an extended charge distribution, these corrections are derived up to terms of order (alpha)**2 log(alpha) in the limit of a short-range hadronic interaction. We infer a charged pion-proton scattering length of 0.0870(5) in units of inverse pion mass, which gives for the charged pion-proton-neutron coupling, through the GMO relation, a value of 14.04(17).

  1. Embedded RFID Recorder in short-range wireless devices

    DEFF Research Database (Denmark)

    2010-01-01

    range communication devices. The problem is solved in that the portable communications device comprises a wireless communications interface for communicating with another device, a memory and an RFID-recorder for receiving an RFID-signal transmitted from an RFID-interrogator, wherein the device...... is adapted for storing individual received RFID-signals in the memory. An advantage of the invention is that it provides a relatively simple scheme for extracting information from a current environment of a portable communications device. The invention may e.g. be used for adapting listening devices, e...

  2. Direct observation of short-circuit diffusion during the formation of a single cupric oxide nanowire

    International Nuclear Information System (INIS)

    Cheng, C-L; Ma, Y-R; Chou, M H; Huang, C Y; Yeh, V; Wu, S Y

    2007-01-01

    Short-circuit diffusion was observed in a single CuO nanowire synthesized using a thermal oxidation method. The confocal Raman spectra of a single CuO nanowire permit direct observation of the nature of an individual CuO nanowire. The parameter order obtained from the inverse Raman B g 2 peak linewidth results in the length dependence of the linewidth and a short-circuit diffusion length of 3.3 μm. The observed structural information is also consistent with the energy dispersive x-ray spectroscopic mapping. The results confirm that the growth of CuO nanowires occurs through the short-circuit diffusion mechanism

  3. The telomere length dynamic and methods of its assessment.

    Science.gov (United States)

    Lin, Kah-Wai; Yan, Ju

    2005-01-01

    Human telomeres are composed of long repeating sequences of TTAGGG, associated with a variety of telomere-binding proteins. Its function as an end-protector of chromosomes prevents the chromosome from end-to-end fusion, recombination and degradation. Telomerase acts as reverse transcriptase in the elongation of telomeres, which prevent the loss of telomeres due to the end replication problems. However, telomerase activity is detected at low level in somatic cells and high level in embryonic stem cells and tumor cells. It confers immortality to embryonic stem cells and tumor cells. In most tumor cells, telomeres are extremely short and stable. Telomere length is an important indicator of the telomerase activity in tumor cells and it may be used in the prognosis of malignancy. Thus, the assessment of telomeres length is of great experimental and clinical significance. This review describes the role of telomere and telomerase in cancer pathogenesis and the dynamics of the telomeres length in different cell types. The various methods of measurement of telomeres length, i.e. southern blot, hybridization protection assay, fluorescence in situ hybridization, primed in situ, quantitative PCR and single telomere length analysis are discussed. The principle and comparative evaluation of these methods are reviewed. The detection of G-strand overhang by telomeric-oligonucleotide ligation assay, primer extension/nick translation assay and electron microscopy are briefly discussed.

  4. Reducing Length of Stay in Total Joint Arthroplasty Care.

    Science.gov (United States)

    Walters, Megan; Chambers, Monique C; Sayeed, Zain; Anoushiravani, Afshin A; El-Othmani, Mouhanad M; Saleh, Khaled J

    2016-10-01

    As health care reforms continue to improve quality of care, significant emphasis will be placed on evaluation of orthopedic patient outcomes. Total joint arthroplasty (TJA) has a proven track record of enhancing patient quality of life and are easily replicable. The outcomes of these procedures serve as a measure of health care initiative success. Specifically, length of stay, will be targeted as a marker of quality of surgical care delivered to TJA patients. Within this review, we will discuss preoperative and postoperative methods by which orthopedic surgeons may enhance TJA outcomes and effectively reduce length of stay. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Performance of the SRK/T formula using A-Scan ultrasound biometry after phacoemulsification in eyes with short and long axial lengths.

    Science.gov (United States)

    Karabela, Yunus; Eliacik, Mustafa; Kaya, Faruk

    2016-07-08

    with PE and IOL types, AL, K1, K2, IOL power, and attempted value, besides with MAE and AL, K1, K2, age, attempted, achieved value were found in both groups. The SRK/T formula performs well and shows good predictability in eyes with short and long axial lengths.

  6. Choked flow mechanism of HFC-134a flowing through short-tube orifices

    Energy Technology Data Exchange (ETDEWEB)

    Nilpueng, Kitti; Wongwises, Somchai [Fluid Mechanics, Thermal Engineering and Multiphase Flow Research Lab (FUTURE), Department of Mechanical Engineering, King Mongkut' s University of Technology Thonburi, Bangmod, Bangkok (Thailand)

    2011-02-15

    This paper is a continuation of the author's previous work. New experimental data on the occurrence of choked flow phenomenon and mass flow rate of HFC-134a inside short-tube orifices under choked flow condition are presented. Short-tube orifices diameters ranging from 0.406 mm to 0.686 mm with lengths ranging from 1 mm to 3 mm which can be applied to a miniature vapour-compression refrigeration system are examined. The experimental results indicated that the occurrence of choked flow phenomena inside short-tube orifices is different from that obtained from short-tube orifice diameters of greater than 1 mm, which are typically used in air-conditioner. The beginning of choked flow is dependent on the downstream pressure, degree of subcooling, and length-to-diameter ratio. Under choked flow condition, the mass flow rate is greatly varied with the short-tube orifice dimension, but it is slightly affected by the operating conditions. A correlation of mass flow rate through short-tube orifices is proposed in terms of the dimensionless parameters. The predicted results show good agreement with experimental data with a mean deviation of 4.69%. (author) transfer coefficient was also proposed. (author)

  7. On the short distance behavior of string theories

    International Nuclear Information System (INIS)

    Guida, R.; Konishi, K.; Provero, P.

    1991-01-01

    Short distance behavior of string theories is investigated by the use of the discretized path-integral formulation. In particular, the minimum physical length and the generalized uncertainty relation are re-derived from a set of Ward-Takahashi identities. In this paper several issues related to the form of the generalized uncertainty relation and to its implications are discussed. A consistent qualitative picture of short distance behavior of string theory seems to emerge from such a study

  8. Lactation yield: Interval level comparison of milk records for genetic ...

    African Journals Online (AJOL)

    Milk recording intervals was studied by analysing 1220 lactation records of Friesian x Arsi crossbred cows kept in south eastern highlands of Ethiopia. Milk Recording Intervals (MRI) comparison was made at 15, 30 and 45 day's length. Accuracy was measured in terms of percentage difference between actual and estimated ...

  9. Lengths of Orthologous Prokaryotic Proteins Are Affected by Evolutionary Factors

    Directory of Open Access Journals (Sweden)

    Tatiana Tatarinova

    2015-01-01

    Full Text Available Proteins of the same functional family (for example, kinases may have significantly different lengths. It is an open question whether such variation in length is random or it appears as a response to some unknown evolutionary driving factors. The main purpose of this paper is to demonstrate existence of factors affecting prokaryotic gene lengths. We believe that the ranking of genomes according to lengths of their genes, followed by the calculation of coefficients of association between genome rank and genome property, is a reasonable approach in revealing such evolutionary driving factors. As we demonstrated earlier, our chosen approach, Bubble-sort, combines stability, accuracy, and computational efficiency as compared to other ranking methods. Application of Bubble Sort to the set of 1390 prokaryotic genomes confirmed that genes of Archaeal species are generally shorter than Bacterial ones. We observed that gene lengths are affected by various factors: within each domain, different phyla have preferences for short or long genes; thermophiles tend to have shorter genes than the soil-dwellers; halophiles tend to have longer genes. We also found that species with overrepresentation of cytosines and guanines in the third position of the codon (GC3 content tend to have longer genes than species with low GC3 content.

  10. Lengths of Orthologous Prokaryotic Proteins Are Affected by Evolutionary Factors.

    Science.gov (United States)

    Tatarinova, Tatiana; Salih, Bilal; Dien Bard, Jennifer; Cohen, Irit; Bolshoy, Alexander

    2015-01-01

    Proteins of the same functional family (for example, kinases) may have significantly different lengths. It is an open question whether such variation in length is random or it appears as a response to some unknown evolutionary driving factors. The main purpose of this paper is to demonstrate existence of factors affecting prokaryotic gene lengths. We believe that the ranking of genomes according to lengths of their genes, followed by the calculation of coefficients of association between genome rank and genome property, is a reasonable approach in revealing such evolutionary driving factors. As we demonstrated earlier, our chosen approach, Bubble-sort, combines stability, accuracy, and computational efficiency as compared to other ranking methods. Application of Bubble Sort to the set of 1390 prokaryotic genomes confirmed that genes of Archaeal species are generally shorter than Bacterial ones. We observed that gene lengths are affected by various factors: within each domain, different phyla have preferences for short or long genes; thermophiles tend to have shorter genes than the soil-dwellers; halophiles tend to have longer genes. We also found that species with overrepresentation of cytosines and guanines in the third position of the codon (GC3 content) tend to have longer genes than species with low GC3 content.

  11. Telomere length is associated with ACE I/D polymorphism in hypertensive patients with left ventricular hypertrophy

    DEFF Research Database (Denmark)

    Fyhrquist, Frej; Eriksson, Anders; Saijonmaa, Outi

    2013-01-01

    INTRODUCTION: Short telomeres are often associated with cardiovascular risk factors and age-related diseases, while the angiotensin converting enzyme (ACE) gene insertion/deletion polymorphism (DD, ID, II) has shown such associations less consistently. We hypothesized that telomere length...... and association of telomere length with cardiovascular risk is affected by ACE (I/D) genotype. METHODS: We measured leucocyte telomere length (LTL) by Southern blot and analysed ACE I/D genotypes in 1249 subjects with hypertension and left ventricular hypertrophy (LVH). We examined interactions of ACE I...

  12. Dicer-independent processing of short hairpin RNAs

    NARCIS (Netherlands)

    Liu, Ying Poi; Schopman, Nick C. T.; Berkhout, Ben

    2013-01-01

    Short hairpin RNAs (shRNAs) are widely used to induce RNA interference (RNAi). We tested a variety of shRNAs that differed in stem length and terminal loop size and revealed strikingly different RNAi activities and shRNA-processing patterns. Interestingly, we identified a specific shRNA design that

  13. Paroxysmal nocturnal hemoglobinuria and telomere length predicts response to immunosuppressive therapy in pediatric aplastic anemia.

    Science.gov (United States)

    Narita, Atsushi; Muramatsu, Hideki; Sekiya, Yuko; Okuno, Yusuke; Sakaguchi, Hirotoshi; Nishio, Nobuhiro; Yoshida, Nao; Wang, Xinan; Xu, Yinyan; Kawashima, Nozomu; Doisaki, Sayoko; Hama, Asahito; Takahashi, Yoshiyuki; Kudo, Kazuko; Moritake, Hiroshi; Kobayashi, Masao; Kobayashi, Ryoji; Ito, Etsuro; Yabe, Hiromasa; Ohga, Shouichi; Ohara, Akira; Kojima, Seiji

    2015-12-01

    Acquired aplastic anemia is an immune-mediated disease characterized by severe defects in stem cell number resulting in hypocellular marrow and peripheral blood cytopenias. Minor paroxysmal nocturnal hemoglobinuria populations and a short telomere length were identified as predictive biomarkers of immunosuppressive therapy responsiveness in aplastic anemia. We enrolled 113 aplastic anemia patients (63 boys and 50 girls) in this study to evaluate their response to immunosuppressive therapy. The paroxysmal nocturnal hemoglobinuria populations and telomere length were detected by flow cytometry. Forty-seven patients (42%) carried a minor paroxysmal nocturnal hemoglobinuria population. The median telomere length of aplastic anemia patients was -0.99 standard deviation (SD) (range -4.01-+3.01 SD). Overall, 60 patients (53%) responded to immunosuppressive therapy after six months. Multivariate logistic regression analysis identified the absence of a paroxysmal nocturnal hemoglobinuria population and a shorter telomere length as independent unfavorable predictors of immunosuppressive therapy response at six months. The cohort was stratified into a group of poor prognosis (paroxysmal nocturnal hemoglobinuria negative and shorter telomere length; 37 patients) and good prognosis (paroxysmal nocturnal hemoglobinuria positive and/or longer telomere length; 76 patients), respectively. The response rates of the poor prognosis and good prognosis groups at six months were 19% and 70%, respectively (P<0.001). The combined absence of a minor paroxysmal nocturnal hemoglobinuria population and a short telomere length is an efficient predictor of poor immunosuppressive therapy response, which should be considered while deciding treatment options: immunosuppressive therapy or first-line hematopoietic stem cell transplantation. The trial was registered in www.umin.ac.jp with number UMIN000017972. Copyright© Ferrata Storti Foundation.

  14. Influence of the gauge length on the accuracy of long-gauge sensors employed in monitoring of prismatic beams

    International Nuclear Information System (INIS)

    Glisic, Branko

    2011-01-01

    Depending on the geometric basis of measurement (gauge length), discrete strain sensors used in structural monitoring of civil engineering structures can be considered as short-gauge sensors or long-gauge sensors. Long-gauge sensors measure average strain over the gauge lengths and are used for global monitoring of structures, in particular, those built of inhomogeneous materials. However, the strain distribution along the sensor's gauge length may be nonlinear and the measured average strain value that is commonly attributed to the midpoint of the sensor may be different from the real value of strain at that point. Consequently, excessively long sensors may feature significant errors in measurement. However, short-gauge sensors are more susceptible to other types of measurement error, most notably, error caused by discontinuities (open cracks) distributed in the monitored material. Thus an optimum gauge length is to be found. The error in average strain measurement inherent to the sensor's gauge length introduced by the strain distribution and discontinuities in the monitored material is modelled for the most common applications met in civil engineering practice. The modelling takes into account the geometric properties of the monitored structure and various load cases. Guidelines for the selection of an appropriate gauge length are proposed, and tables for measurement error estimation are presented

  15. The School Short-Form Coopersmith Self-Esteem Inventory: Revised and Improved

    Science.gov (United States)

    Hills, Peter R.; Francis, Leslie J.; Jennings, Penelope

    2011-01-01

    The school short form of the Coopersmith Self-Esteem Inventory is a widely used measure of children's global self-esteem. Unlike the full-length scale, however, it has been generally understood that the short form does not allow differentiation between the major individual sources of self-esteem. The present study has examined the internal…

  16. Anomalous high photoconductivity in short channel indium-zinc-oxide photo-transistors

    International Nuclear Information System (INIS)

    Choi, Hyun-Sik; Jeon, Sanghun

    2015-01-01

    Upon light exposure, an indium-zinc-oxide (IZO) thin-film transistor (TFT) presents higher photoconductivity by several orders of magnitude at the negative gate bias region. Among various device geometrical factors, scaling down the channel length of the photo-transistor results in an anomalous increase in photoconductivity. To probe the origin of this high photoconductivity in short-channel device, we measured transient current, current–voltage, and capacitance–voltage characteristics of IZO–TFTs with various channel lengths and widths before and after illumination. Under the illumination, the equilibrium potential region which lies far from front interface exists only in short-channel devices, forming the un-depleted conducting back channel. This region plays an important role in carrier transport under the illumination, leading to high photoconductivity in short-channel devices. Photon exposure coupled with gate-modulated band bending for short-channel devices leads to the accumulation of V o ++ at the front channel and screening negative gate bias, thereby generating high current flow in the un-depleted back-channel region

  17. Ultrashort Channel Length Black Phosphorus Field-Effect Transistors.

    Science.gov (United States)

    Miao, Jinshui; Zhang, Suoming; Cai, Le; Scherr, Martin; Wang, Chuan

    2015-09-22

    This paper reports high-performance top-gated black phosphorus (BP) field-effect transistors with channel lengths down to 20 nm fabricated using a facile angle evaporation process. By controlling the evaporation angle, the channel length of the transistors can be reproducibly controlled to be anywhere between 20 and 70 nm. The as-fabricated 20 nm top-gated BP transistors exhibit respectable on-state current (174 μA/μm) and transconductance (70 μS/μm) at a VDS of 0.1 V. Due to the use of two-dimensional BP as the channel material, the transistors exhibit relatively small short channel effects, preserving a decent on-off current ratio of 10(2) even at an extremely small channel length of 20 nm. Additionally, unlike the unencapsulated BP devices, which are known to be chemically unstable in ambient conditions, the top-gated BP transistors passivated by the Al2O3 gate dielectric layer remain stable without noticeable degradation in device performance after being stored in ambient conditions for more than 1 week. This work demonstrates the great promise of atomically thin BP for applications in ultimately scaled transistors.

  18. Paired-Pulse TMS and Fine-Wire Recordings Reveal Short-Interval Intracortical Inhibition and Facilitation of Deep Multifidus Muscle Fascicles.

    Directory of Open Access Journals (Sweden)

    Hugo Massé-Alarie

    Full Text Available Paired-pulse transcranial magnetic stimulation (ppTMS is used to probe inhibitory and excitatory networks within the primary motor cortex (M1. These mechanisms are identified for limb muscles but it is unclear whether they share properties with trunk muscles. The aim was to determine whether it was possible to test the intracortical inhibition and facilitation of the deep multifidus muscle fascicles (DM and at which inter-stimulus intervals (ISI.In ten pain-free individuals, TMS was applied over M1 and motor evoked potentials (MEP were recorded using fine-wire electrodes in DM. MEPs were conditioned with subthreshold stimuli at ISIs of 1 to 12 ms to test short-interval intracortical inhibition (SICI and at 15 ms for long-interval intracortical facilitation. Short-interval facilitation (SICF was tested using 1-ms ISI.SICI of DM was consistently obtained with ISI of 1-, 3-, 4- and 12-ms. Facilitation of DM MEP was only identified using SICF paradigm.A similar pattern of MEP modulation with ISI changes for deep trunk and limb muscles implies that M1 networks share some functional properties.The ppTMS paradigm presents a potential to determine how M1 inhibitory and excitatory mechanisms participate in brain re-organization in back pain that affects control of trunk muscles.

  19. Effects of Presentation Format and List Length on Children's False Memories

    Science.gov (United States)

    Swannell, Ellen R.; Dewhurst, Stephen A.

    2013-01-01

    The effect of list length on children's false memories was investigated using list and story versions of the Deese/Roediger-McDermott procedure. Short (7 items) and long (14 items) sequences of semantic associates were presented to children aged 6, 8, and 10 years old either in lists or embedded within a story that emphasized the list theme.…

  20. Effeciency of extracorporeal shock wave therapy in patients with plantar fasciitis and the relationship with subcalcaneal spur length

    Directory of Open Access Journals (Sweden)

    Serpil Tuna

    2014-06-01

    Full Text Available Objective: ESWT is widely used in the treatment of plantar fascitis. In this study, we aimed to investigate the effect of ESWT on heel pain and symptoms in the short and medium term. We also compared the subcalcaneal spur length and the heel pain severity and examined the effect of the subcalcaneal spur length on the efficiency of ESWT therapy. Methods: The efficiency of ESWT applied to 59 heel of 48 patients compared retrospectively . We used Visual Analog Scale (VAS and Wolgin scale to evaluate the treatment outcomes. We measure the subcalcaneal spurs length of the patients with foot x-ray . Correlation between the VAS scores and the length of subcalcaneal spur were also evaluated. Results: Improvement in VAS in the first week and 3 months after ESWT treatment was statistically significant. There was no correlation between subcalcaneal spur length and the severity of pain. The number of patients in the'' medium, bad'' group decreased while the number of patients in the '' good'' group incresed according to WDS after ESWT treatment. Conclusion: As a result of this study we concluded that ESWT is effective in the treatment of plantar fasciitis in the short and medium term.

  1. A population-based study on the association between educational length, prostate-specific antigen testing and use of prostate biopsies.

    Science.gov (United States)

    Nordström, Tobias; Bratt, Ola; Örtegren, Joakim; Aly, Markus; Adolfsson, Jan; Grönberg, Henrik

    2016-01-01

    The aim of this study was to determine whether educational length affects prostate-specific antigen (PSA) testing and the time to prostate biopsy for men with raised PSA values. Using register data on all men in Stockholm County in 2013 (n = 1,052,841), the limited-duration point prevalence of PSA testing and time between test and prostate biopsy or repeat testing were analysed. Patterns of follow-up were assessed using Kaplan-Meier product limit estimators and Cox proportional hazard models. Educational length was categorized as short (≤ 9 years), intermediate (10-12 years) or long (≥ 13 years). PSA testing increased with educational length in all age groups. Among men aged 50-69 years, 61% with long and 54% with short education had had a PSA test within the preceding 10 years (p prostate biopsy within 12 months. After adjusting for PSA level and age, educational length was still associated with the chance of having a prostate biopsy in men with PSA 4-10 ng/ml (hazard ratio 1.22, 95% CI 1.12-1.31), but not in men with higher PSA values. PSA testing increased with educational length. Men with long education were more likely to have a prostate biopsy after an increased PSA value below 10 ng/ml than men with short education. These differences may contribute to the worse prostate cancer outcomes observed among men with lower socioeconomic status.

  2. The effect of shape, length and diameter of implants on primary stability based on resonance frequency analysis

    Directory of Open Access Journals (Sweden)

    Hamidreza Barikani

    2014-01-01

    Full Text Available Background: The aim of this in vitro study was to evaluate the effect of shape, diameter and length of implants on their primary stability based on resonance frequency analysis. Materials and Methods: Replace select tapered and Branemark MK III implants were selected. Each of these two selected groups was divided into nine subgroups based on the implant length (IL (short, medium and long and the implant diameter (ID (narrow platform [NP], regular platform [RP] and wide platform [WP]. Five implants were assigned to each of the nine subgroups. Implants were placed in artificial bone blocks with bone quality similar to D3 bone. Immediately after the implant placement, its primary stability was measured using Osstell Mentor equipment. T-test and Tukey′s honest significant difference Post hoc were performed for data analysis. Statistical significance was defined at P < 0.05. Results: Replace select system showed significantly higher primary stability compared to the Branemark system, when using the short implants for all three diameters (P ≤ 0.004. However, in medium length implants there were no significant differences between the two implant systems (P ≥ 0.31. In long implants, only when the NP and RP implants were used, the Replace Select system showed significantly higher primary stability compared to the Branemark system (P = 0.000. In the replace select system, long implants had a significantly higher primary stability compared to medium and short length implants (P ≤ 0.003. In the NP and RP Branemark implants, short implants showed significantly lower primary stability compared to medium and long implants (P ≤ 0.002. However, in WP Branemark implants, primary stability increased significantly with increasing the IL from short to medium and from medium to long (P = 0.000. There were also significant differences between NP and the two other wider implants in both systems (P = 0.000. Conclusion: The use of tapered implants is

  3. Zen meditation, Length of Telomeres, and the Role of Experiential Avoidance and Compassion.

    Science.gov (United States)

    Alda, Marta; Puebla-Guedea, Marta; Rodero, Baltasar; Demarzo, Marcelo; Montero-Marin, Jesus; Roca, Miquel; Garcia-Campayo, Javier

    Mindfulness refers to an awareness that emerges by intentionally focusing on the present experience in a nonjudgmental or evaluative manner. Evidence regarding its efficacy has been increasing exponentially, and recent research suggests that the practice of meditation is associated with longer leukocyte telomere length. However, the psychological mechanisms underlying this potential relationship are unknown. We examined the telomere lengths of a group of 20 Zen meditation experts and another 20 healthy matched comparison participants who had not previously meditated. We also measured multiple psychological variables related to meditation practice. Genomic DNA was extracted for telomere measurement using a Life Length proprietary program. High-throughput quantitative fluorescence in situ hybridization (HT-Q-FISH) was used to measure the telomere length distribution and the median telomere length (MTL). The meditators group had a longer MTL ( p  = 0.005) and a lower percentage of short telomeres in individual cells ( p  = 0.007) than those in the comparison group. To determine which of the psychological variables contributed more to telomere maintenance, two regression analyses were conducted. In the first model, which applied to the MTL, the following three factors were significant: age, absence of experiential avoidance, and Common Humanity subscale of the Self Compassion Scale. Similarly, in the model that examined the percentage of short telomeres, the same factors were significant: age, absence of experiential avoidance, and Common Humanity subscale of the Self Compassion Scale. Although limited by a small sample size, these results suggest that the absence of experiential avoidance of negative emotions and thoughts is integral to the connection between meditation and telomeres.

  4. Laser interferometry in length measurement. Proceedings. Laserinterferometrie in der Laengenmesstechnik. Vortraege

    Energy Technology Data Exchange (ETDEWEB)

    1985-01-01

    Wavelength-stabilized lasers for length measurement, measurements of the refractive index of air, laser interferometers, acceptance tests of laser interferometer systems, the Michelson interferometer with semiconductor laser, and the state of the art of optical gyroscopes for angular position measurement are described in the general section. The examples of laser interferometer applications in production engineering comprise automatic acceptance testing of coordinate measuring systems, simultaneous laser measurements of the position and the pitching, yansing and rolling angles along a measuring line, a 3D-interferometer length measuring system, the calibration of standard measures, angular position measurements, straightness measurements, and laser interferometers as installed length measuring systems in machine tools and measuring machinery. There are no separate records of the 13 lectures presented at the meeting. (DG).

  5. Compliant walking appears metabolically advantageous at extreme step lengths.

    Science.gov (United States)

    Kim, Jaehoon; Bertram, John E A

    2018-05-19

    Humans alter gait in response to unusual gait circumstances to accomplish the task of walking. For instance, subjects spontaneously increase leg compliance at a step length threshold as step length increases. Here we test the hypothesis that this transition occurs based on the level of energy expenditure, where compliant walking becomes less energetically demanding at long step lengths. To map and compare the metabolic cost of normal and compliant walking as step length increases. 10 healthy individuals walked on a treadmill using progressively increasing step lengths (100%, 120%, 140% and 160% of preferred step length), in both normal and compliant leg walking as energy expenditure was recorded via indirect calorimetry. Leg compliance was controlled by lowering the center-of-mass trajectory during stance, forcing the leg to flex and extend as the body moved over the foot contact. For normal step lengths, compliant leg walking was more costly than normal walking gait, but compliant leg walking energetic cost did not increase as rapidly for longer step lengths. This led to an intersection between normal and compliant walking cost curves at 114% relative step length (regression analysis; r 2  = 0.92 for normal walking; r 2  = 0.65 for compliant walking). Compliant leg walking is less energetically demanding at longer step lengths where a spontaneous shift to compliant walking has been observed, suggesting the human motor control system is sensitive to energetic requirements and will employ alternate movement patterns if advantageous strategies are available. The transition could be attributed to the interplay between (i) leg work controlling body travel during single stance and (ii) leg work to control energy loss in the step-to-step transition. Compliant leg walking requires more stance leg work at normal step lengths, but involves less energy loss at the step-to-step transition for very long steps. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Study of force induced melting of dsDNA as a function of length and conformation

    International Nuclear Information System (INIS)

    Danilowicz, Claudia; Hatch, Kristi; Conover, Alyson; Gunaratne, Ruwan; Coljee, Vincent; Prentiss, Mara; Ducas, Theodore

    2010-01-01

    We measure the constant force required to melt double-stranded (ds) DNA as a function of length for lengths from 12 to 100 000 base pairs, where the force is applied to the 3'3' or 5'5' ends of the dsDNA. Molecules with 32 base pairs or fewer melt before overstretching. For these short molecules, the melting force is independent of the ends to which the force is applied and the shear force as a function of length is well described by de Gennes theory with a de Gennes length of less than 10 bp. Molecules with lengths of 500 base pairs or more overstretch before melting. For these long molecules, the melting force depends on the ends to which the force is applied. The melting force as a function of length increases even when the length exceeds 1000 bp, where the length dependence is inconsistent with de Gennes theory. Finally, we expand de Gennes melting theory to 3'5' pulling and compare the predictions with experimental results.

  7. A Comparison of the Interest Accuracy of Two Short Forms of the WAIS-R.

    Science.gov (United States)

    Cella, David F.; And Others

    1985-01-01

    Examined relative efficacy of two short forms of Wechsler Adult Intelligence Scale-Revised (WAIS-R) with respect to accurate subtest profile scatter (N=50). Subtest scores of both split-half Satz-Mogel short form and criterion referenced Modified WAIS-R (WAIS-RM) short form were found to differ significantly from full-length WAIS-R subtest scores.…

  8. The effect of genotype and birth type on gestation length and linear ...

    African Journals Online (AJOL)

    The effect of genotype and birth type on gestation length and linear body ... was conducted in Enugu State University of Science and Technology, in the then ... Weekly weights and live body measurements of the kids were recorded from ...

  9. Evaluation of Short Term Memory Span Function In Children

    OpenAIRE

    Barış ERGÜL; Arzu ALTIN YAVUZ; Ebru GÜNDOĞAN AŞIK

    2016-01-01

    Although details of the information encoded in the short-term memory where it is stored temporarily be recorded in the working memory in the next stage. Repeating the information mentally makes it remain in memory for a long time. Studies investigating the relationship between short-term memory and reading skills that are carried out to examine the relationship between short-term memory processes and reading comprehension. In this study information coming to short-term memory and the factors ...

  10. Influence of step length and landing pattern on patellofemoral joint kinetics during running.

    Science.gov (United States)

    Willson, J D; Ratcliff, O M; Meardon, S A; Willy, R W

    2015-12-01

    Elevated patellofemoral joint kinetics during running may contribute to patellofemoral joint symptoms. The purpose of this study was to test for independent effects of foot strike pattern and step length on patellofemoral joint kinetics while running. Effects were tested relative to individual steps and also taking into account the number of steps required to run a kilometer with each step length. Patellofemoral joint reaction force and stress were estimated in 20 participants running at their preferred speed. Participants ran using a forefoot strike and rearfoot strike pattern during three different step length conditions: preferred step length, long (+10%) step length, and short (-10%) step length. Patellofemoral kinetics was estimated using a biomechanical model of the patellofemoral joint that accounted for cocontraction of the knee flexors and extensors. We observed independent effects of foot strike pattern and step length. Patellofemoral joint kinetics per step was 10-13% less during forefoot strike conditions and 15-20% less with a shortened step length. Patellofemoral joint kinetics per kilometer decreased 12-13% using a forefoot strike pattern and 9-12% with a shortened step length. To the extent that patellofemoral joint kinetics contribute to symptoms among runners, these running modifications may be advisable for runners with patellofemoral pain. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Short-Circuit Degradation of 10-kV 10-A SiC MOSFET

    DEFF Research Database (Denmark)

    Eni, Emanuel-Petre; Beczkowski, Szymon; Munk-Nielsen, Stig

    2017-01-01

    The short-circuit behavior of power devices is highly relevant for converter design and fault protection. In this work, the degradation during short-circuit of a 10 kV 10 A 4H-SiC MOSFET is investigated at 6 kV DC-link voltage. The study aims to present the behavior of the device during short-circuit...... transients as it sustains increasing short-circuit pulses during its life-time. As the short-circuit pulse length increases, degradation of the device can be observed in periodically performed characterizations. The initial degradation seems to be associated with the channel region, and continuous stressing...

  12. Probabilistic Segmentation of Folk Music Recordings

    Directory of Open Access Journals (Sweden)

    Ciril Bohak

    2016-01-01

    Full Text Available The paper presents a novel method for automatic segmentation of folk music field recordings. The method is based on a distance measure that uses dynamic time warping to cope with tempo variations and a dynamic programming approach to handle pitch drifting for finding similarities and estimating the length of repeating segment. A probabilistic framework based on HMM is used to find segment boundaries, searching for optimal match between the expected segment length, between-segment similarities, and likely locations of segment beginnings. Evaluation of several current state-of-the-art approaches for segmentation of commercial music is presented and their weaknesses when dealing with folk music are exposed, such as intolerance to pitch drift and variable tempo. The proposed method is evaluated and its performance analyzed on a collection of 206 folk songs of different ensemble types: solo, two- and three-voiced, choir, instrumental, and instrumental with singing. It outperforms current commercial music segmentation methods for noninstrumental music and is on a par with the best for instrumental recordings. The method is also comparable to a more specialized method for segmentation of solo singing folk music recordings.

  13. Recurrence of gastroesophageal reflux disease correlated with a short dinner-to-bedtime interval.

    Science.gov (United States)

    Yang, Jae Hoon; Kang, Ho Suk; Lee, Sun-Young; Kim, Jeong Hwan; Sung, In-Kyung; Park, Hyung Seok; Shim, Chan Sup; Jin, Choon Jo

    2014-04-01

    Gastroesophageal reflux disease (GERD) can be classified into erosive reflux disease (ERD) and nonerosive gastroesophageal reflux disease (NERD). We aimed to compare the recurrence rates of ERD and NERD and determine the risk factors related to the recurrence. This prospective study comprised 337 consecutive adults who completed questionnaires on their GERD symptoms, height, weight, sleeping position, dinner time, and bedtime. During upper gastrointestinal endoscopy, the presence of a hiatal hernia and mucosal breaks in the low esophagus, esophageal length (the distance between the Z-line and the incisors), and the esophageal length-to-height ratio were recorded. Recurrence was diagnosed when the patient required additional proton pump inhibitor medication after initial recovery with 4-8 weeks of treatment. Recurrence was experienced by 47 (26.0%) of 181 GERD patients. The recurrence rate did not differ between the 48 ERD (27.1%) and 133 NERD (25.6%) patients (P = 0.849). Of the various factors studied, recurrence was found to be correlated with a dinner-to-bedtime interval of less than 3 h (P = 0.002), globus sensation (P = 0.031), and old age (P = 0.047). Logistic regression analysis revealed that a short interval between dinner and bedtime was the only factor significantly related to the recurrence (P = 0.002). Both ERD and NERD patients who sleep within 3 h after eating have a higher risk of GERD recurrence. Our findings highlight the impact of a short dinner-to-bedtime interval on the recurrence of GERD (ClinicalTrials.gov ID: KCT0000134). © 2013 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  14. Changes in muscle force-length properties affect the early rise of force in vivo

    DEFF Research Database (Denmark)

    Blazevich, Anthony J; Cannavan, Dale; Horne, Sara

    2009-01-01

    Changes in contractile rate of force development (RFD), measured within a short time interval from contraction initiation, were measured after a period of strength training that led to increases in muscle fascicle length but no measurable change in neuromuscular activity. The relationship between...

  15. In situ detection of tandem DNA repeat length

    Energy Technology Data Exchange (ETDEWEB)

    Yaar, R.; Szafranski, P.; Cantor, C.R.; Smith, C.L. [Boston Univ., MA (United States)

    1996-11-01

    A simple method for scoring short tandem DNA repeats is presented. An oligonucleotide target, containing tandem repeats embedded in a unique sequence, was hybridized to a set of complementary probes, containing tandem repeats of known lengths. Single-stranded loop structures formed on duplexes containing a mismatched (different) number of tandem repeats. No loop structure formed on duplexes containing a matched (identical) number of tandem repeats. The matched and mismatched loop structures were enzymatically distinguished and differentially labeled by treatment with S1 nuclease and the Klenow fragment of DNA polymerase. 7 refs., 4 figs.

  16. SeqEntropy: genome-wide assessment of repeats for short read sequencing.

    Directory of Open Access Journals (Sweden)

    Hsueh-Ting Chu

    Full Text Available BACKGROUND: Recent studies on genome assembly from short-read sequencing data reported the limitation of this technology to reconstruct the entire genome even at very high depth coverage. We investigated the limitation from the perspective of information theory to evaluate the effect of repeats on short-read genome assembly using idealized (error-free reads at different lengths. METHODOLOGY/PRINCIPAL FINDINGS: We define a metric H(k to be the entropy of sequencing reads at a read length k and use the relative loss of entropy ΔH(k to measure the impact of repeats for the reconstruction of whole-genome from sequences of length k. In our experiments, we found that entropy loss correlates well with de-novo assembly coverage of a genome, and a score of ΔH(k>1% indicates a severe loss in genome reconstruction fidelity. The minimal read lengths to achieve ΔH(k<1% are different for various organisms and are independent of the genome size. For example, in order to meet the threshold of ΔH(k<1%, a read length of 60 bp is needed for the sequencing of human genome (3.2 10(9 bp and 320 bp for the sequencing of fruit fly (1.8×10(8 bp. We also calculated the ΔH(k scores for 2725 prokaryotic chromosomes and plasmids at several read lengths. Our results indicate that the levels of repeats in different genomes are diverse and the entropy of sequencing reads provides a measurement for the repeat structures. CONCLUSIONS/SIGNIFICANCE: The proposed entropy-based measurement, which can be calculated in seconds to minutes in most cases, provides a rapid quantitative evaluation on the limitation of idealized short-read genome sequencing. Moreover, the calculation can be parallelized to scale up to large euakryotic genomes. This approach may be useful to tune the sequencing parameters to achieve better genome assemblies when a closely related genome is already available.

  17. FIELD INVESTIGATIONS OF PILED-RAFT FOUNDATIONS WITH SHORT-LENGTH CONIC PILES IN BUILDING AREAS OF MINSK

    Directory of Open Access Journals (Sweden)

    V. A. Sernov

    2015-01-01

    Full Text Available In recent time piled foundations are extensively applied due to an increase of storeys in buildings constructed in Minsk and load increment on the soil. Preference is given to this approach even in the case when relatively firm soil occurs in the top part of the foundation bed. In this case maximum usage of the foundation bed bearing capacity and reduction of foundation cost are considered as top-priority tasks for designers. One of the ways to increase the bearing capacity of piled foundations is the necessity to take into account resistance of foundation bed soil located under raft bottom. The raft as well as a shallow foundation is capable to transfer a significant part of building load into the soil. Such approach makes it possible to reduce a number of piles in the foundation or shorten their length. Then it results in shortening of the construction period and significant reduction in zero cycle. However up to the present moment reliable calculation methods that permit to take into account soil resistance in the raft base. An analysis of previous investigations on the matter executed by various researchers and a number of field investigations have been carried out with the purpose to develop the proposed methods.The paper presents results of field investigations on foundations consisting of short stamped tapered piles which are joined together with the help of the raft fragment. Strength and deformation characteristics of the bases are increasing while making such foundations in the fill-up soil. In this case the filled-up ground layer becomes a bearing layer both for piles and rafts as well. Improvement of high-plastic clay-bearing soil properties is ensured by ramming dry concrete mix under pile foot. The paper describes an experience on application of the piled-raft foundation in complicated engineering and geological conditions while constructing the Orthodox Church in Minsk.

  18. Are environmental characteristics in the municipal eldercare, more closely associated with frequent short sick leave spells among employees than with total sick leave: a cross-sectional study

    Science.gov (United States)

    2013-01-01

    Background It has been suggested that frequent-, short-term sick leave is associated with work environment factors, whereas long-term sick leave is associated mainly with health factors. However, studies of the hypothesis of an association between a poor working environment and frequent short spells of sick leave are few and results are inconsistent. Therefore, we aimed to explore associations between self-reported psychosocial work factors and workplace-registered frequency and length of sick leave in the eldercare sector. Methods Employees from the municipal eldercare in Aarhus (N = 2,534) were included. In 2005, they responded to a work environment questionnaire. Sick leave records from 2005 were dichotomised into total sick leave days (0–14 and above 14 days) and into spell patterns (0–2 short, 3–9 short, and mixed spells and 1–3 long spells). Logistic regression models were used to analyse associations; adjusted for age, gender, occupation, and number of spells or sick leave length. Results The response rate was 76%; 96% of the respondents were women. Unfavourable mean scores in work pace, demands for hiding emotions, poor quality of leadership and bullying were best indicated by more than 14 sick leave days compared with 0–14 sick leave days. For work pace, the best indicator was a long-term sick leave pattern compared with a non-frequent short-term pattern. A frequent short-term sick leave pattern was a better indicator of emotional demands (1.62; 95% CI: 1.1-2.5) and role conflict (1.50; 95% CI: 1.2-1.9) than a short-term non-frequent pattern. Age (= 40 years) statistically significantly modified the association between the 1–3 long-term sick leave spell pattern and commitment to the workplace compared with the 3–9 frequent short-term pattern. Conclusions Total sick leave length and a long-term sick leave spell pattern were just as good or even better indicators of unfavourable work factor scores than a frequent short-term sick leave

  19. CORRELATION BETWEEN PENIS LENGTH AND ANTHOPOMETRY OF 5 YEAR OLD CHILDREN

    Directory of Open Access Journals (Sweden)

    Doddy Kurnia Indrawan

    2013-03-01

    Full Text Available Short penis still a problem for parents. Penis lenght is associated with  weight and considered abnormal in obese children. The purpose of this study was to find out the correlation between penis length and the anthropometry children aged 5 years. A cross sectional study was conducted, at the Division of Endocrinology, Department of Child Health, Medical Faculty of Udayana University, Sanglah Hospital Denpasar, during October 2010, at TK Sayang Ibu Sanglah Hospital. The calculation of the sample with a correlation coefficient of weight and  height obtained  9 people, taking in consecutive sampling and analyzed  with Pearson’s correlation. The mean body weight was 23.6 (SD 7.70 kg;  mean child height was 108.4 (SD 5.3 cm, and 47.1% were obese. The mean length of the penis was 4.7(SD1.30 cm. The correlation between weight and penis lenght was strong negative (r = -0.876; P = 0.000 and between penis length and height was r = -0.597; P = 0,011.There was a strong negative correlation between body weight and penis length and also negative correlation between penis length and height in kindergarten children. (MEDICINA 2012;43:19-22.

  20. Laser interferometric method for determining the carrier diffusion length in semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Manukhov, V. V. [Saint Petersburg State University (Russian Federation); Fedortsov, A. B.; Ivanov, A. S., E-mail: ivaleks58@gmail.com [Saint Petersburg Mining University (Russian Federation)

    2015-09-15

    A new laser interferometric method for measuring the carrier diffusion length in semiconductors is proposed. The method is based on the interference–absorption interaction of two laser radiations in a semiconductor. Injected radiation generates additional carriers in a semiconductor, which causes a change in the material’s optical constants and modulation of the probing radiation passed through the sample. When changing the distance between carrier generation and probing points, a decrease in the carrier concentration, which depends on the diffusion length, is recorded. The diffusion length is determined by comparing the experimental and theoretical dependences of the probe signal on the divergence of the injector and probe beams. The method is successfully tested on semiconductor samples with different thicknesses and surface states and can be used in scientific research and the electronics industry.

  1. A short leucocyte telomere length is associated with development of insulin resistance

    DEFF Research Database (Denmark)

    Verhulst, Simon; Dalgård, Christine; Labat, Carlos

    2016-01-01

    AIMS/HYPOTHESIS: A number of studies have shown that leucocyte telomere length (LTL) is inversely associated with insulin resistance and type 2 diabetes mellitus. The aim of the present longitudinal cohort study, utilising a twin design, was to assess whether shorter LTL predicts insulin resistance...... and insulin resistance over an average of 12 years were performed in a subset of the Registry consisting of 338 (184 monozygotic and 154 dizygotic) same-sex twin pairs. RESULTS: Age at baseline examination was 37.4 ± 9.6 (mean ± SD) years. Baseline insulin resistance was not associated with age......-dependent changes in LTL (attrition) over the follow-up period, whereas baseline LTL was associated with changes in insulin resistance during this period. The shorter the LTL at baseline, the more pronounced was the increase in insulin resistance over the follow-up period (p 

  2. The transition from longitudinal to perpendicular recording

    International Nuclear Information System (INIS)

    Richter, H J

    2007-01-01

    After more than 30 years of research, hard disk drives using perpendicular recording are finally commercially available. This review is a follow-up of a review written in 1999 and addresses the basic physics of perpendicular recording with special emphasis on the read and the write process and the magnetic aspects of the recording media. The paper also surveys various technical difficulties which prevented an earlier implementation of perpendicular recording. The paper closes with a short overview of alternative technologies that allow even higher storage densities. (topical review)

  3. Practice of teaching in (microhistory and cinematographic language: the short-length movie as ‘another’ historical narrative in and at the place

    Directory of Open Access Journals (Sweden)

    Humberto Perinelli Neto

    2012-01-01

    Full Text Available This article has the objective to rethink concepts, contents and objectives of themes connected with the area of History through the articulation between the use of audiovisual languages – in case, the cinema – the role of the narrative and the construction of practices of teaching, all based on the studies of micro-history. We do not want to discuss only the educational and empirical potential of the technological resources inside the classrooms, but, specially, we want to understand the possible and real ways of transformation of the students, when they turn into subjects who creates new knowledges, by making short-length movies. This pedagogic tool and technological can help us think about the PCN's prerogatives, like, the increase in value of the place and of the daily life (of the pupils, the respect to the diversity and plurality, the role of the subjects in History. The proposal here presented is a result of a project carried out at the Fundação Educacional de Fernandópolis between 2009 and 2010, as works of conclusion of course developed by pupils of the degree course in History.

  4. Genetic association of telomere length with hepatocellular carcinoma risk: A Mendelian randomization analysis.

    Science.gov (United States)

    Cheng, Yue; Yu, Chengxiao; Huang, Mingtao; Du, Fangzhi; Song, Ci; Ma, Zijian; Zhai, Xiangjun; Yang, Yuan; Liu, Jibin; Bei, Jin-Xin; Jia, Weihua; Jin, Guangfu; Li, Shengping; Zhou, Weiping; Liu, Jianjun; Dai, Juncheng; Hu, Zhibin

    2017-10-01

    Observational studies show an association between telomere length and Hepatocellular carcinoma (HCC) risk, but the relationship is controversial. Particularly, it remains unclear whether the association is due to confounding or biases inherent in conventional epidemiological studies. Here, we applied Mendelian randomization approach to evaluate whether telomere length is causally associated with HCC risk. Individual-level data were from HBV-related HCC Genome-wide association studies (1,538 HBV positive HCC patients and 1,465 HBV positive controls). Genetic risk score, as proxy for actual measured telomere length, derived from nine telomere length-associated genetic variants was used to evaluate the effect of telomere length on HCC risk. We observed a significant risk signal between genetically increased telomere length and HBV-related HCC risk (OR=2.09, 95% CI 1.32-3.31, P=0.002). Furthermore, a U-shaped curve was fitted by the restricted cubic spline curve, which indicated that either short or long telomere length would increase HCC risk (P=0.0022 for non-linearity test). Subgroup analysis did not reveal significant heterogeneity between different age, gender, smoking status and drinking status groups. Our results indicated that a genetic background that favors longer or shorter telomere length may increase HBV-related HCC risk-a U-shaped association. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. The bacterial nanorecorder: engineering E. coli to function as a chemical recording device.

    Science.gov (United States)

    Bhomkar, Prasanna; Materi, Wayne; Wishart, David S

    2011-01-01

    Synthetic biology is an emerging branch of molecular biology that uses synthetic genetic constructs to create man-made cells or organisms that are capable of performing novel and/or useful applications. Using a synthetic chemically sensitive genetic toggle switch to activate appropriate fluorescent protein indicators (GFP, RFP) and a cell division inhibitor (minC), we have created a novel E. coli strain that can be used as a highly specific, yet simple and inexpensive chemical recording device. This biological "nanorecorder" can be used to determine both the type and the time at which a brief chemical exposure event has occurred. In particular, we show that the short-term exposure (15-30 min) of cells harboring this synthetic genetic circuit to small molecule signals (anhydrotetracycline or IPTG) triggered long-term and uniform cell elongation, with cell length being directly proportional to the time elapsed following a brief chemical exposure. This work demonstrates that facile modification of an existing genetic toggle switch can be exploited to generate a robust, biologically-based "nanorecorder" that could potentially be adapted to detect, respond and record a wide range of chemical stimuli that may vary over time and space.

  6. Analytic solution to variance optimization with no short positions

    Science.gov (United States)

    Kondor, Imre; Papp, Gábor; Caccioli, Fabio

    2017-12-01

    We consider the variance portfolio optimization problem with a ban on short selling. We provide an analytical solution by means of the replica method for the case of a portfolio of independent, but not identically distributed, assets. We study the behavior of the solution as a function of the ratio r between the number N of assets and the length T of the time series of returns used to estimate risk. The no-short-selling constraint acts as an asymmetric \

  7. Short Communications: First record of freshwater fish on the Cape ...

    African Journals Online (AJOL)

    During a non-exhaustive survey of freshwater bodies on five islands of the archipelago, the first presence of a freshwater fish was recorded. Using barcoding sequences, the species was identified as the guppy (Poecilia reticulata), a highly invasive species alien to the Cape Verdean Islands. Key words: Cape Verde, guppy, ...

  8. The effect of lactation length on greenhouse gas emissions from the national dairy herd.

    Science.gov (United States)

    Wall, E; Coffey, M P; Pollott, G E

    2012-11-01

    Many governments have signed up to greenhouse gas emission (GHGE) reduction programmes under their national climate change obligations. Recently, it has been suggested that the use of extended lactations in dairy herds could result in reduced GHGE. Dairy GHGE were modelled on a national basis and the model was used to compare emissions from lactations of three different lengths (305, 370 and 440 days), and a current 'base' scenario on the basis of maintaining current milk production levels. In addition to comparing GHGE from the average 'National Herd' under these scenarios, results were used to investigate how accounting for lactations of different lengths might alter the estimation of emissions calculated from the National Inventory methodology currently recommended by Intergovernmental Panel on Climate Change. Data for the three lactation length scenarios were derived from nationally recorded dairy performance information and used in the GHGE model. Long lactations required fewer milking cows and replacements to maintain current milk yield levels than short ones, but GHGEs were found to rise from 1214 t of CO2 equivalent (CE)/farm per year for lactations of 305 days to 1371 t CE/farm per year for 440-day lactations. This apparent anomaly can be explained by the less efficient milk production (kg milk produced per kg cow weight) found in later lactation, a more pronounced effect in longer lactations. The sensitivity of the model to changes in replacement rate, persistency and level of milk yield was investigated. Changes in the replacement rate from 25% to 20% and in persistency by −10% to +20% resulted in very small changes in GHGE. Differences in GHGE due to the level of milk yield were much more dramatic with animals in the top 10% for yield, producing about 25% less GHGE/year than the average animal. National Inventory results were investigated using a more realistic spread of lactation lengths than recommended for such calculations using emissions

  9. The effect of regular strength training on telomere length in human skeletal muscle

    DEFF Research Database (Denmark)

    Kadi, F.; Ponsot, Elodie; Piehl-Aulin, Karin

    2008-01-01

    PURPOSE: The length of DNA telomeres is an important parameter of the proliferative potential of tissues. A recent study has reported abnormally short telomeres in skeletal muscle of athletes with exercise-associated fatigue. This important report raises the question of whether long-term practice...... of sports might have deleterious effects on muscle telomeres. Therefore, we aimed to compare telomere length of a group of power lifters (PL; N = 7) who trained for 8 +/- 3 yr against that of a group of healthy, active subjects (C; N = 7) with no history of strength training. METHODS: Muscle biopsies were...

  10. Length of stay in asylum centres and mental health in asylum seekers

    DEFF Research Database (Denmark)

    Hallas, Peter; Hansen, Anne R; Staehr, Mia A

    2007-01-01

    BACKGROUND: The length of stay in asylum centres is generally mentioned as a possible health risk to asylum seekers. Medical staff working with asylum seekers has claimed that long lengths of stay in asylum centres might cause or aggravate mental disorders. We used records from a large, multiethnic...... specialists. If an asylum seeker needed more than three specialist consultations for mental illness or five consultations for physical illness the referrals had to be approved by The Danish Immigration Service. Between July 2001 - December 2002 the Red Cross prospectively registered health related data on all......: Length of stay in asylum centres was associated with an increase in referrals for mental disorders in a large, multiethnic group of asylum seekers. The present study supports the view that prolonged length of stay in an asylum centre is a risk factor for mental health. The risk of psychiatric illness...

  11. A comparison of discriminant logistic regression and Item Response Theory Likelihood-Ratio Tests for Differential Item Functioning (IRTLRDIF) in polytomous short tests.

    Science.gov (United States)

    Hidalgo, María D; López-Martínez, María D; Gómez-Benito, Juana; Guilera, Georgina

    2016-01-01

    Short scales are typically used in the social, behavioural and health sciences. This is relevant since test length can influence whether items showing DIF are correctly flagged. This paper compares the relative effectiveness of discriminant logistic regression (DLR) and IRTLRDIF for detecting DIF in polytomous short tests. A simulation study was designed. Test length, sample size, DIF amount and item response categories number were manipulated. Type I error and power were evaluated. IRTLRDIF and DLR yielded Type I error rates close to nominal level in no-DIF conditions. Under DIF conditions, Type I error rates were affected by test length DIF amount, degree of test contamination, sample size and number of item response categories. DLR showed a higher Type I error rate than did IRTLRDIF. Power rates were affected by DIF amount and sample size, but not by test length. DLR achieved higher power rates than did IRTLRDIF in very short tests, although the high Type I error rate involved means that this result cannot be taken into account. Test length had an important impact on the Type I error rate. IRTLRDIF and DLR showed a low power rate in short tests and with small sample sizes.

  12. Characterising the large coherence length at diamond’s beamline I13L

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, U. H., E-mail: ulrich.wagner@diamond.ac.uk; Parsons, A. [Diamond Light Source Ltd, Didcot, UK, OX11 0DE (United Kingdom); Rahomaki, J.; Vogt, U. [KTH Royal Institute of Technology, Stockholm, Sweden, SE-100 44 (Sweden); Rau, C. [Diamond Light Source Ltd, Didcot, UK, OX11 0DE (United Kingdom); Northwestern University, Chicago, IL 60611-3008 (United States)

    2016-07-27

    I13 is a 250 m long hard x-ray beamline (6 keV to 35 keV) at the Diamond Light Source. The beamline comprises of two independent experimental endstations: one for imaging in direct space using x-ray microscopy and one for imaging in reciprocal space using coherent diffraction based imaging techniques [1]. An outstanding feature of the coherence branch, due to its length and a new generation of ultra-stable beamline instrumentation [2], is its capability of delivering a very large coherence length well beyond 200 μm, providing opportunities for unique x-ray optical experiments. In this paper we discuss the challenges of measuring a large coherence length and present quantitative measurement based on analyzing diffraction patterns from a boron fiber [3]. We also discuss the limitations of this classical method in respect to detector performance, very short and long coherence lengths. Furthermore we demonstrate how a Ronchi grating setup [4] can be used to quickly establish if the beam is coherent over a large area.

  13. Characterising the large coherence length at diamond’s beamline I13L

    International Nuclear Information System (INIS)

    Wagner, U. H.; Parsons, A.; Rahomaki, J.; Vogt, U.; Rau, C.

    2016-01-01

    I13 is a 250 m long hard x-ray beamline (6 keV to 35 keV) at the Diamond Light Source. The beamline comprises of two independent experimental endstations: one for imaging in direct space using x-ray microscopy and one for imaging in reciprocal space using coherent diffraction based imaging techniques [1]. An outstanding feature of the coherence branch, due to its length and a new generation of ultra-stable beamline instrumentation [2], is its capability of delivering a very large coherence length well beyond 200 μm, providing opportunities for unique x-ray optical experiments. In this paper we discuss the challenges of measuring a large coherence length and present quantitative measurement based on analyzing diffraction patterns from a boron fiber [3]. We also discuss the limitations of this classical method in respect to detector performance, very short and long coherence lengths. Furthermore we demonstrate how a Ronchi grating setup [4] can be used to quickly establish if the beam is coherent over a large area.

  14. Short-length and high-density TiO{sub 2} nanorod arrays for the efficient charge separation interface in perovskite solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Guannan; Shi, Chengwu, E-mail: shicw506@foxmail.com; Zhang, Zhengguo; Li, Nannan; Li, Long

    2017-05-15

    Preparation of TiO{sub 2} nanorod array with length of 70 nm and density of 1000 µm{sup −2}. • Influence of annealing temperatures on the -OH content of TiO{sub 2} nanorod arrays. • Preparation of over-500 nm-thickness CH{sub 3}NH{sub 3}PbI{sub 3−x}Br{sub x} absorber layer. • Combination of short-length TiO{sub 2} nanorod array and high-thickness perovskite layer. • The best and average PCE with TiO{sub 2} array of 15.93% and 13.41±2.52% at 50–54% RH.

  15. Short-term visual memory properties sheet secondary school age with different levels of physical development

    Directory of Open Access Journals (Sweden)

    E.E. Menshikh

    2013-12-01

    Full Text Available Purpose . The results presented properties of short-term visual memory with different levels of physical development. Materials and methods. The study included 405 boys and girls Cherkassy school 11 in age from 13 to 16 years. Study of short-term visual memory was carried out using tables with 10 characters ( numbers and ambiguous geometric shapes . Indicator memory was the higher, the more information was displayed. Measured the length and body weight was recorded cardiorespiratory indicators - heart rate at rest and after 20 squats, lung capacity, breath-hold inspiration and expiration. Physical development factor was calculated by taking into account actual and average population indices. Results . Found that the volume of short-term visual memory, the boys and girls high school age does not depend on the level of their physical development. Despite the fact that the trend towards higher performance memory in groups of persons with a high level of physical development compared to their same age with medium and low levels, significant differences between the mean values for the most part have been identified. No significant differences between the values of the investigated cognitive function in groups by sex. Conclusions . Growth pattern memory with age in this period of ontogenesis preserved that coincides with the data presented in the scientific works of scientists.

  16. The Impact of Video Length on Learning in a Middle-Level Flipped Science Setting: Implications for Diversity Inclusion

    Science.gov (United States)

    Slemmons, Krista; Anyanwu, Kele; Hames, Josh; Grabski, Dave; Mlsna, Jeffery; Simkins, Eric; Cook, Perry

    2018-05-01

    Popularity of videos for classroom instruction has increased over the years due to affordability and user-friendliness of today's digital video cameras. This prevalence has led to an increase in flipped, K-12 classrooms countrywide. However, quantitative data establishing the appropriate video length to foster authentic learning is limited, particularly in middle-level classrooms. We focus on this aspect of video technology in two flipped science classrooms at the middle school level to determine the optimal video length to enable learning, increase retention and support student motivation. Our results indicate that while assessments directly following short videos were slightly higher, these findings were not significantly different from scores following longer videos. While short-term retention of material did not seem to be influenced by video length, longer-term retention for males and students with learning disabilities was higher following short videos compared to long as assessed on summative assessments. Students self-report that they were more engaged, had enhanced focus, and had a perceived higher retention of content following shorter videos. This study has important implications for student learning, application of content, and the development of critical thinking skills. This is particularly paramount in an era where content knowledge is just a search engine away.

  17. The isotope record of short- and long-term dietary changes in sheep tooth enamel: Implications for quantitative reconstruction of paleodiets

    Science.gov (United States)

    Zazzo, A.; Balasse, M.; Passey, B. H.; Moloney, A. P.; Monahan, F. J.; Schmidt, O.

    2010-06-01

    Quantitative reconstruction of paleodiet by means of sequential sampling and carbon isotope analysis in hypsodont tooth enamel requires a precise knowledge of the isotopic enrichment between dietary carbon and carbon from enamel apatite ( ɛD-E), as well as of the timing and duration of the enamel mineralization process (amelogenesis). To better constrain these parameters, we performed a series of controlled feeding experiments on sheep ranging in age from 6 to 24 months-old. Twenty-eight lambs and 14 ewes were fed isotopically distinct diets for different periods of time, and then slaughtered, allowing the timing and rate of molar growth to be determined. High resolution sampling and stable carbon isotope analysis of breath CO 2 performed on six individuals following a diet-switch showed that 70-90% of dietary carbon had turned over in less than 24 h. Sequential sampling and carbon isotopic analysis was performed on the first (M 1) and second (M 2) lower molars of four lambs as well as on the third lower molar (M 3) of 11 ewes. The changes in diet were recorded in all molars. We found that the length of enamel matrix apposition is approximately one-quarter of the final tooth length during crown extension, and that enamel maturation spans slightly less than 3 months in M 1, and 4 months in M 2 and M 3. Portions of enamel in equilibrium with dietary carbon were used to calculate ɛD-E values. Animals on grass silage diets had values similar to previous observations, whereas animal switched to pelleted corn diets had values ca. 4‰ lower, a pattern consistent with lower methane production observed for animals fed concentrate diets. The tooth enamel forward model of Passey and Cerling (2002) closely predicted the amplitude of isotope changes recorded in tooth enamel, but slightly underestimated the rate of isotope change, suggesting that the rate of accumulation of carbonate during maturation may not be constant over time. Although stable isotope profiles in tooth

  18. A case of 45,X/47,XXX mosaic Turner syndrome with limb length discrepancy.

    Science.gov (United States)

    Hishimura-Yonemaru, Nozomi; Okuhara, Koji; Takahashi, Nobuhiro; Tonoki, Hidefumi; Iizuka, Susumu; Tajima, Toshihiro

    2017-01-01

    Patients with Turner syndrome (TS) frequently show short stature and skeletal deformities, such as kyphosis and scoliosis. However, to the best of our knowledge, limb length discrepancy (LLD) has not yet been reported in patients with TS. The case of a 12-yr-old girl with 45,X/47,XXX mosaic TS showing LLD is herein presented. She was on GH therapy for short stature and was noted to have scoliosis in the standing position at a regular examination; however, the scoliosis became less evident in the supine position, which is indicative of LLD. The length of the left leg was 5.0 cm shorter than that of the right leg when measured. She was referred to orthopedics and underwent right distal femoral and right proximal tibial staple epiphysiodesis to shorten the abnormally long limb at 10 yr 6 mo of age. One year after the operation, the LLD decreased from 5.0 to 1.5 cm. During this period, GH was continued. LLD is a rare complication in TS, but when patients with TS show scoliosis in the standing position, re-evaluation for scoliosis in the supine position should be performed and the lengths of both legs should be measured.

  19. Short-term memory and electrical restitution in the canine transmural ventricle

    International Nuclear Information System (INIS)

    Zhang, Hong; Ueyama, Takeshi; Lin, Shien-Fong; Wang, Juan; Wu, Rui-Juan

    2011-01-01

    Cardiac short-term memory is an intrinsic property of paced myocardium that reflects the influence of pacing history. Using an optical mapping method to record membrane voltage and intracellular calcium (Ca 2+ i ), this study investigated the properties and mechanisms of short-term memory in isolated and perfused canine wedge preparations. In addition to the dynamic and S1S2 pacing protocols, a perturbed downsweep pacing protocol was used to get a complete overview of the restitution portrait. Abrupt changes in basic cycle length (BCL) were applied to investigate the accommodation process of action potential duration (APD). The results showed unobvious differences of memory among the epi-, mid- and endo-myocytes, implying an insignificant memory-induced transient heterogeneity in APD across the transmural canine hearts. With the decrease of pacing rate S1, memory gradually elevated and achieved a maximum around 400 ms, and then reduced as S1 decreased further, indicating a non-monotonic relationship between memory and the pacing rate. After suppressing the Ca 2+ i transient with ryanodine (3 µmol l −1 ), the accommodation process of APD to a new BCL significantly abbreviated (τ = 37.41 ± 4.42 stimuli before ryanodine, τ = 15.84 ± 4.74 stimuli after ryanodine, p < 0.01). Therefore, Ca 2+ i cycling was suggested to play an important role in memory during dynamic pacing

  20. Read length and repeat resolution: Exploring prokaryote genomes using next-generation sequencing technologies

    KAUST Repository

    Cahill, Matt J.

    2010-07-12

    Background: There are a growing number of next-generation sequencing technologies. At present, the most cost-effective options also produce the shortest reads. However, even for prokaryotes, there is uncertainty concerning the utility of these technologies for the de novo assembly of complete genomes. This reflects an expectation that short reads will be unable to resolve small, but presumably abundant, repeats. Methodology/Principal Findings: Using a simple model of repeat assembly, we develop and test a technique that, for any read length, can estimate the occurrence of unresolvable repeats in a genome, and thus predict the number of gaps that would need to be closed to produce a complete sequence. We apply this technique to 818 prokaryote genome sequences. This provides a quantitative assessment of the relative performance of various lengths. Notably, unpaired reads of only 150nt can reconstruct approximately 50% of the analysed genomes with fewer than 96 repeat-induced gaps. Nonetheless, there is considerable variation amongst prokaryotes. Some genomes can be assembled to near contiguity using very short reads while others require much longer reads. Conclusions: Given the diversity of prokaryote genomes, a sequencing strategy should be tailored to the organism under study. Our results will provide researchers with a practical resource to guide the selection of the appropriate read length. 2010 Cahill et al.

  1. Read length and repeat resolution: exploring prokaryote genomes using next-generation sequencing technologies.

    Directory of Open Access Journals (Sweden)

    Matt J Cahill

    Full Text Available BACKGROUND: There are a growing number of next-generation sequencing technologies. At present, the most cost-effective options also produce the shortest reads. However, even for prokaryotes, there is uncertainty concerning the utility of these technologies for the de novo assembly of complete genomes. This reflects an expectation that short reads will be unable to resolve small, but presumably abundant, repeats. METHODOLOGY/PRINCIPAL FINDINGS: Using a simple model of repeat assembly, we develop and test a technique that, for any read length, can estimate the occurrence of unresolvable repeats in a genome, and thus predict the number of gaps that would need to be closed to produce a complete sequence. We apply this technique to 818 prokaryote genome sequences. This provides a quantitative assessment of the relative performance of various lengths. Notably, unpaired reads of only 150nt can reconstruct approximately 50% of the analysed genomes with fewer than 96 repeat-induced gaps. Nonetheless, there is considerable variation amongst prokaryotes. Some genomes can be assembled to near contiguity using very short reads while others require much longer reads. CONCLUSIONS: Given the diversity of prokaryote genomes, a sequencing strategy should be tailored to the organism under study. Our results will provide researchers with a practical resource to guide the selection of the appropriate read length.

  2. Read length and repeat resolution: Exploring prokaryote genomes using next-generation sequencing technologies

    KAUST Repository

    Cahill, Matt J.; Kö ser, Claudio U.; Ross, Nicholas E.; Archer, John A.C.

    2010-01-01

    Background: There are a growing number of next-generation sequencing technologies. At present, the most cost-effective options also produce the shortest reads. However, even for prokaryotes, there is uncertainty concerning the utility of these technologies for the de novo assembly of complete genomes. This reflects an expectation that short reads will be unable to resolve small, but presumably abundant, repeats. Methodology/Principal Findings: Using a simple model of repeat assembly, we develop and test a technique that, for any read length, can estimate the occurrence of unresolvable repeats in a genome, and thus predict the number of gaps that would need to be closed to produce a complete sequence. We apply this technique to 818 prokaryote genome sequences. This provides a quantitative assessment of the relative performance of various lengths. Notably, unpaired reads of only 150nt can reconstruct approximately 50% of the analysed genomes with fewer than 96 repeat-induced gaps. Nonetheless, there is considerable variation amongst prokaryotes. Some genomes can be assembled to near contiguity using very short reads while others require much longer reads. Conclusions: Given the diversity of prokaryote genomes, a sequencing strategy should be tailored to the organism under study. Our results will provide researchers with a practical resource to guide the selection of the appropriate read length. 2010 Cahill et al.

  3. Retrieval of long and short lists from long term memory: a functional magnetic resonance imaging study with human subjects.

    Science.gov (United States)

    Zysset, S; Müller, K; Lehmann, C; Thöne-Otto, A I; von Cramon, D Y

    2001-11-13

    Previous studies have shown that reaction time in an item-recognition task with both short and long lists is a quadratic function of list length. This suggests that either different memory retrieval processes are implied for short and long lists or an adaptive process is involved. An event-related functional magnetic resonance imaging study with nine subjects and list lengths varying between 3 and 18 words was conducted to identify the underlying neuronal structures of retrieval from long and short lists. For the retrieval and processing of word-lists a single fronto-parietal network, including premotor, left prefrontal, left precuneal and left parietal regions, was activated. With increasing list length, no additional regions became involved in retrieving information from long-term memory, suggesting that not necessarily different, but highly adaptive retrieval processes are involved.

  4. Road safety performance measures and AADT uncertainty from short-term counts.

    Science.gov (United States)

    Milligan, Craig; Montufar, Jeannette; Regehr, Jonathan; Ghanney, Bartholomew

    2016-12-01

    The objective of this paper is to enable better risk analysis of road safety performance measures by creating the first knowledge base on uncertainty surrounding annual average daily traffic (AADT) estimates when the estimates are derived by expanding short-term counts with the individual permanent counter method. Many road safety performance measures and performance models use AADT as an input. While there is an awareness that the input suffers from uncertainty, the uncertainty is not well known or accounted for. The paper samples data from a set of 69 permanent automatic traffic recorders in Manitoba, Canada, to simulate almost 2 million short-term counts over a five year period. These short-term counts are expanded to AADT estimates by transferring temporal information from a directly linked nearby permanent count control station, and the resulting AADT values are compared to a known reference AADT to compute errors. The impacts of five factors on AADT error are considered: length of short-term count, number of short-term counts, use of weekday versus weekend counts, distance from a count to its expansion control station, and the AADT at the count site. The mean absolute transfer error for expanded AADT estimates is 6.7%, and this value varied by traffic pattern group from 5% to 10.5%. Reference percentiles of the error distribution show that almost all errors are between -20% and +30%. Error decreases substantially by using a 48-h count instead of a 24-h count, and only slightly by using two counts instead of one. Weekday counts are superior to weekend counts, especially if the count is only 24h. Mean absolute transfer error increases with distance to control station (elasticity 0.121, p=0.001), and increases with AADT (elasticity 0.857, proad safety performance measures that use AADT as inputs. Analytical frameworks for such analysis exist but are infrequently used in road safety because the evidence base on AADT uncertainty is not well developed. Copyright

  5. Nanowire failure: long = brittle and short = ductile.

    Science.gov (United States)

    Wu, Zhaoxuan; Zhang, Yong-Wei; Jhon, Mark H; Gao, Huajian; Srolovitz, David J

    2012-02-08

    Experimental studies of the tensile behavior of metallic nanowires show a wide range of failure modes, ranging from ductile necking to brittle/localized shear failure-often in the same diameter wires. We performed large-scale molecular dynamics simulations of copper nanowires with a range of nanowire lengths and provide unequivocal evidence for a transition in nanowire failure mode with change in nanowire length. Short nanowires fail via a ductile mode with serrated stress-strain curves, while long wires exhibit extreme shear localization and abrupt failure. We developed a simple model for predicting the critical nanowire length for this failure mode transition and showed that it is in excellent agreement with both the simulation results and the extant experimental data. The present results provide a new paradigm for the design of nanoscale mechanical systems that demarcates graceful and catastrophic failure. © 2012 American Chemical Society

  6. High-Density Near-Field Optical Disc Recording

    Science.gov (United States)

    Shinoda, Masataka; Saito, Kimihiro; Ishimoto, Tsutomu; Kondo, Takao; Nakaoki, Ariyoshi; Ide, Naoki; Furuki, Motohiro; Takeda, Minoru; Akiyama, Yuji; Shimouma, Takashi; Yamamoto, Masanobu

    2005-05-01

    We developed a high-density near-field optical recording disc system using a solid immersion lens. The near-field optical pick-up consists of a solid immersion lens with a numerical aperture of 1.84. The laser wavelength for recording is 405 nm. In order to realize the near-field optical recording disc, we used a phase-change recording media and a molded polycarbonate substrate. A clear eye pattern of 112 GB capacity with 160 nm track pitch and 50 nm bit length was observed. The equivalent areal density is 80.6 Gbit/in2. The bottom bit error rate of 3 tracks-write was 4.5× 10-5. The readout power margin and the recording power margin were ± 30.4% and ± 11.2%, respectively.

  7. Effects of age, gender, and stimulus presentation period on visual short-term memory.

    Science.gov (United States)

    Kunimi, Mitsunobu

    2016-01-01

    This study focused on age-related changes in visual short-term memory using visual stimuli that did not allow verbal encoding. Experiment 1 examined the effects of age and the length of the stimulus presentation period on visual short-term memory function. Experiment 2 examined the effects of age, gender, and the length of the stimulus presentation period on visual short-term memory function. The worst memory performance and the largest performance difference between the age groups were observed in the shortest stimulus presentation period conditions. The performance difference between the age groups became smaller as the stimulus presentation period became longer; however, it did not completely disappear. Although gender did not have a significant effect on d' regardless of the presentation period in the young group, a significant gender-based difference was observed for stimulus presentation periods of 500 ms and 1,000 ms in the older group. This study indicates that the decline in visual short-term memory observed in the older group is due to the interaction of several factors.

  8. Androgen receptor CAG repeats length polymorphism and the risk of polycystic ovarian syndrome (PCOS.

    Directory of Open Access Journals (Sweden)

    Singh Rajender

    Full Text Available OBJECTIVE: Polycystic ovarian syndrome (PCOS refers to an inheritable androgen excess disorder characterized by multiple small follicles located at the ovarian periphery. Hyperandrogenism in PCOS, and inverse correlation between androgen receptor (AR CAG numbers and AR function, led us to hypothesize that CAG length variations may affect PCOS risk. METHODS: CAG repeat region of 169 patients recruited following strictly defined Rotterdam (2003 inclusion criteria and that of 175 ethnically similar control samples, were analyzed. We also conducted a meta-analysis on the data taken from published studies, to generate a pooled estimate on 2194 cases and 2242 controls. RESULTS: CAG bi-allelic mean length was between 8.5 and 24.5 (mean = 17.43, SD = 2.43 repeats in the controls and between 11 and 24 (mean = 17.39, SD = 2.29 repeats in the cases, without any significant difference between the two groups. Further, comparison of bi-allelic mean and its frequency distribution in three categories (short, moderate and long alleles did not show any significant difference between controls and various case subgroups. Frequency distribution of bi-allelic mean in two categories (extreme and moderate alleles showed over-representation of extreme sized alleles in the cases with marginally significant value (50.3% vs. 61.5%, χ(2 = 4.41; P = 0.036, which turned insignificant upon applying Bonferroni correction for multiple comparisons. X-chromosome inactivation analysis showed no significant difference in the inactivation pattern of CAG alleles or in the comparison of weighed bi-allelic mean between cases and controls. Meta-analysis also showed no significant correlation between CAG length and PCOS risk, except a minor over-representation of short CAG alleles in the cases. CONCLUSION: CAG bi-allelic mean length did not differ between controls and cases/case sub-groups nor did the allele distribution. Over-representation of short

  9. Androgen receptor CAG repeats length polymorphism and the risk of polycystic ovarian syndrome (PCOS).

    Science.gov (United States)

    Rajender, Singh; Carlus, Silas Justin; Bansal, Sandeep Kumar; Negi, Mahendra Pal Singh; Negi, Mahendra Pratap Singh; Sadasivam, Nirmala; Sadasivam, Muthusamy Narayanan; Thangaraj, Kumarasamy

    2013-01-01

    Polycystic ovarian syndrome (PCOS) refers to an inheritable androgen excess disorder characterized by multiple small follicles located at the ovarian periphery. Hyperandrogenism in PCOS, and inverse correlation between androgen receptor (AR) CAG numbers and AR function, led us to hypothesize that CAG length variations may affect PCOS risk. CAG repeat region of 169 patients recruited following strictly defined Rotterdam (2003) inclusion criteria and that of 175 ethnically similar control samples, were analyzed. We also conducted a meta-analysis on the data taken from published studies, to generate a pooled estimate on 2194 cases and 2242 controls. CAG bi-allelic mean length was between 8.5 and 24.5 (mean = 17.43, SD = 2.43) repeats in the controls and between 11 and 24 (mean = 17.39, SD = 2.29) repeats in the cases, without any significant difference between the two groups. Further, comparison of bi-allelic mean and its frequency distribution in three categories (short, moderate and long alleles) did not show any significant difference between controls and various case subgroups. Frequency distribution of bi-allelic mean in two categories (extreme and moderate alleles) showed over-representation of extreme sized alleles in the cases with marginally significant value (50.3% vs. 61.5%, χ(2) = 4.41; P = 0.036), which turned insignificant upon applying Bonferroni correction for multiple comparisons. X-chromosome inactivation analysis showed no significant difference in the inactivation pattern of CAG alleles or in the comparison of weighed bi-allelic mean between cases and controls. Meta-analysis also showed no significant correlation between CAG length and PCOS risk, except a minor over-representation of short CAG alleles in the cases. CAG bi-allelic mean length did not differ between controls and cases/case sub-groups nor did the allele distribution. Over-representation of short/extreme-sized alleles in the cases may be a chance finding

  10. Length-scale and strain rate-dependent mechanism of defect formation and fracture in carbon nanotubes under tensile loading

    Energy Technology Data Exchange (ETDEWEB)

    Javvaji, Brahmanandam [Indian Institute of Science, Department of Aerospace Engineering (India); Raha, S. [Indian Institute of Science, Department of Computational and Data Sciences (India); Mahapatra, D. Roy, E-mail: droymahapatra@aero.iisc.ernet.in [Indian Institute of Science, Department of Aerospace Engineering (India)

    2017-02-15

    Electromagnetic and thermo-mechanical forces play a major role in nanotube-based materials and devices. Under high-energy electron transport or high current densities, carbon nanotubes fail via sequential fracture. The failure sequence is governed by certain length scale and flow of current. We report a unified phenomenological model derived from molecular dynamic simulation data, which successfully captures the important physics of the complex failure process. Length-scale and strain rate-dependent defect nucleation, growth, and fracture in single-walled carbon nanotubes with diameters in the range of 0.47 to 2.03 nm and length which is about 6.17 to 26.45 nm are simulated. Nanotubes with long length and small diameter show brittle fracture, while those with short length and large diameter show transition from ductile to brittle fracture. In short nanotubes with small diameters, we observe several structural transitions like Stone-Wales defect initiation, its propagation to larger void nucleation, formation of multiple chains of atoms, conversion to monatomic chain of atoms, and finally complete fracture of the carbon nanotube. Hybridization state of carbon-carbon bonds near the end cap evolves, leading to the formation of monatomic chain in short nanotubes with small diameter. Transition from ductile to brittle fracture is also observed when strain rate exceeds a critical value. A generalized analytical model of failure is established, which correlates the defect energy during the formation of atomic chain with aspect ratio of the nanotube and strain rate. Variation in the mechanical properties such as elastic modulus, tensile strength, and fracture strain with the size and strain rate shows important implications in mitigating force fields and ways to enhance the life of electronic devices and nanomaterial conversion via fracture in manufacturing.

  11. The Effects of Input Enhancement and Text Length on Adult L2 Readers' Comprehension and Intake in Second Language Acquisition.

    Science.gov (United States)

    Leow, Ronald P.

    1997-01-01

    Investigated the effects of written input enhancement and text length on college students' second-language comprehension and intake. First-year Spanish students were exposed to one of four conditions with enhanced and non-enhanced short and long text. Exposing students to short authentic reading materials facilitated reading comprehension but not…

  12. Standardization of methods of expressing lengths and weights of fish

    Science.gov (United States)

    Hile, Ralph

    1948-01-01

    Fishery workers in the United States and Canada are unable to think readily in terms of the metric system of weights and measurements. Even long experience does not make it possible to form a clear idea as to the actual size of fish for which lengths and weights are given in metric units, without first converting to the English system. A more general adoption of the English system of weights and measurements in fishery work is recommended. The use of English units exclusively is suggested for articles of a popular or semi-popular nature, but in more formal publications the key information, at least, should be recorded in both systems. In highly technical papers metric units alone may prove satisfactory. Agreement is also lacking as to which length measurement of fish is suited best for uniform adoption. The total length is recommended here for the reason that it is the only measurement that includes all of the fish. This length is defined as the distance from the tip of the head (jaws closed) to the tip of the tail with the lobes compressed so as to give the maximum possible measurement.

  13. Short bowel syndrome.

    LENUS (Irish Health Repository)

    Donohoe, Claire L

    2012-02-01

    The short bowel syndrome (SBS) is a state of malabsorption following intestinal resection where there is less than 200 cm of intestinal length. The management of short bowel syndrome can be challenging and is best managed by a specialised multidisciplinary team. A good understanding of the pathophysiological consequences of resection of different portions of the small intestine is necessary to anticipate and prevent, where possible, consequences of SBS. Nutrient absorption and fluid and electrolyte management in the initial stages are critical to stabilisation of the patient and to facilitate the process of adaptation. Pharmacological adjuncts to promote adaptation are in the early stages of development. Primary restoration of bowel continuity, if possible, is the principle mode of surgical treatment. Surgical procedures to increase the surface area of the small intestine or improve its function may be of benefit in experienced hands, particularly in the paediatric population. Intestinal transplant is indicated at present for patients who have failed to tolerate long-term parenteral nutrition but with increasing experience, there may be a potentially expanded role for its use in the future.

  14. Peripheral kisspeptin reverses short photoperiod-induced gonadal regression in Syrian hamsters by promoting GNRH release

    DEFF Research Database (Denmark)

    Ansel, L; Bentsen, A H; Ancel, C

    2011-01-01

    In seasonal breeders, reproduction is synchronised by day length via the pineal hormone melatonin. In short winter days (short day, SD), the Syrian hamster displays a complete gonadal atrophy together with a marked reduction in expression of kisspeptins (Kp), a family of potent hypothalamic stimu...

  15. Empirical scaling of the length of the longest increasing subsequences of random walks

    Science.gov (United States)

    Mendonça, J. Ricardo G.

    2017-02-01

    We provide Monte Carlo estimates of the scaling of the length L n of the longest increasing subsequences of n-step random walks for several different distributions of step lengths, short and heavy-tailed. Our simulations indicate that, barring possible logarithmic corrections, {{L}n}∼ {{n}θ} with the leading scaling exponent 0.60≲ θ ≲ 0.69 for the heavy-tailed distributions of step lengths examined, with values increasing as the distribution becomes more heavy-tailed, and θ ≃ 0.57 for distributions of finite variance, irrespective of the particular distribution. The results are consistent with existing rigorous bounds for θ, although in a somewhat surprising manner. For random walks with step lengths of finite variance, we conjecture that the correct asymptotic behavior of L n is given by \\sqrt{n}\\ln n , and also propose the form for the subleading asymptotics. The distribution of L n was found to follow a simple scaling form with scaling functions that vary with θ. Accordingly, when the step lengths are of finite variance they seem to be universal. The nature of this scaling remains unclear, since we lack a working model, microscopic or hydrodynamic, for the behavior of the length of the longest increasing subsequences of random walks.

  16. Model-based evaluation of the short-circuited tripolar cuff configuration.

    Science.gov (United States)

    Andreasen, Lotte N S; Struijk, Johannes J

    2006-05-01

    Recordings of neural information for use as feedback in functional electrical stimulation are often contaminated with interfering signals from muscles and from stimulus pulses. The cuff electrode used for the neural recording can be optimized to improve the S/I ratio. In this work, we evaluate a model of both the nerve signal and the interfering signals recorded by a cuff, and subsequently use this model to study the signal to interference ratio of different cuff designs and to evaluate a recently introduced short-circuited tripolar cuff configuration. The results of the model showed good agreement with results from measurements in rabbits and confirmed the superior performance of the short-circuited tripolar configuration as compared with the traditionally used tripolar configuration.

  17. Short Carboxylic Acid–Carboxylate Hydrogen Bonds Can Have Fully Localized Protons

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Jiusheng; Pozharski, Edwin; Wilson, Mark A.

    2017-01-17

    Short hydrogen bonds (H-bonds) have been proposed to play key functional roles in several proteins. The location of the proton in short H-bonds is of central importance, as proton delocalization is a defining feature of low-barrier hydrogen bonds (LBHBs). Experimentally determining proton location in H-bonds is challenging. Here, bond length analysis of atomic (1.15–0.98 Å) resolution X-ray crystal structures of the human protein DJ-1 and its bacterial homologue, YajL, was used to determine the protonation states of H-bonded carboxylic acids. DJ-1 contains a buried, dimer-spanning 2.49 Å H-bond between Glu15 and Asp24 that satisfies standard donor–acceptor distance criteria for a LBHB. Bond length analysis indicates that the proton is localized on Asp24, excluding a LBHB at this location. However, similar analysis of the Escherichia coli homologue YajL shows both residues may be protonated at the H-bonded oxygen atoms, potentially consistent with a LBHB. A Protein Data Bank-wide screen identifies candidate carboxylic acid H-bonds in approximately 14% of proteins, which are typically short [O–O> = 2.542(2) Å]. Chemically similar H-bonds between hydroxylated residues (Ser/Thr/Tyr) and carboxylates show a trend of lengthening O–O distance with increasing H-bond donor pKa. This trend suggests that conventional electronic effects provide an adequate explanation for short, charge-assisted carboxylic acid–carboxylate H-bonds in proteins, without the need to invoke LBHBs in general. This study demonstrates that bond length analysis of atomic resolution X-ray crystal structures provides a useful experimental test of certain candidate LBHBs.

  18. Short-term memory predictions across the lifespan: monitoring span before and after conducting a task.

    Science.gov (United States)

    Bertrand, Julie Marilyne; Moulin, Chris John Anthony; Souchay, Céline

    2017-05-01

    Our objective was to explore metamemory in short-term memory across the lifespan. Five age groups participated in this study: 3 groups of children (4-13 years old), and younger and older adults. We used a three-phase task: prediction-span-postdiction. For prediction and postdiction phases, participants reported with a Yes/No response if they could recall in order a series of images. For the span task, they had to actually recall such series. From 4 years old, children have some ability to monitor their short-term memory and are able to adjust their prediction after experiencing the task. However, accuracy still improves significantly until adolescence. Although the older adults had a lower span, they were as accurate as young adults in their evaluation, suggesting that metamemory is unimpaired for short-term memory tasks in older adults. •We investigate metamemory for short-term memory tasks across the lifespan. •We find younger children cannot accurately predict their span length. •Older adults are accurate in predicting their span length. •People's metamemory accuracy was related to their short-term memory span.

  19. Automatic measurement of axial length of human eye using three-dimensional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Watanabe, Masaki; Kiryu, Tohru

    2011-01-01

    The measurement of axial length and the evaluation of three dimensional (3D) form of an eye are essential to evaluate the mechanism of myopia progression. We propose a method of automatic measurement of axial length including adjustment of the pulse sequence of short-term scan which could suppress influence of eyeblink, using a magnetic resonance imaging (MRI) which acquires 3D images noninvasively. Acquiring T 2 -weighted images with 3.0 tesla MRI device and eight-channel phased-array head coil, we extracted left and right eye ball images, and then reconstructed 3D volume. The surface coordinates were calculated from 3D volume, fitting the ellipsoid model coordinates with the surface coordinates, and measured the axial length automatically. Measuring twenty one subjects, we compared the automatically measured values of axial length with the manually measured ones, then confirmed significant elongation in the axial length of myopia compared with that of emmetropia. Furthermore, there were no significant differences (P<0.05) between the means of automatic measurements and the manual ones. Accordingly, the automatic measurement process of axial length could be a tool for the elucidation of the mechanism of myopia progression, which would be suitable for evaluating the axial length easily and noninvasively. (author)

  20. Cervical Length in Patients at Risk for Placenta Accreta.

    Science.gov (United States)

    Rac, Martha W F; McIntire, Donald D; Wells, C Edward; Moschos, Elysia; Twickler, Diane D

    2017-07-01

    To evaluate cervical length measurements in women with placenta accreta compared to women with a nonadherent low-lying placenta or placenta previa and evaluate this relationship in terms of vaginal bleeding, preterm labor, and preterm birth. We conducted a retrospective cohort study between 1997 and 2011 of gravidas with more than 1 prior cesarean delivery who had a transvaginal ultrasound examination between 24 and 34 weeks for a low-lying placenta or placenta previa. Cervical length was measured from archived images in accordance with national guidelines by a single investigator, who was blinded to outcomes and ultrasound reports. The diagnosis of placental accreta was based on histologic confirmation. For study purposes, preterm birth was defined as less than 36 weeks, and cervical lengths of 3 cm or less were considered short. Standard statistical analyses were used. A total of 125 patients met inclusion criteria. The cohort was divided into patients with (n = 43 [34%]) and without (n = 82 [66%]) placenta accreta and stratified by gestational age at the ultrasound examinations. Women with placenta accreta had shorter cervical length measurements during their 32- to 34-week ultrasound examinations (mean ± SD, 3.23 ± 0.98 versus 3.95 ± 1.0 cm; P accreta had shorter cervical lengths at 32 to 34 weeks than women with a nonadherent low-lying placenta or placenta previa, but this finding did not correlate with a higher risk of vaginal bleeding or preterm labor resulting in preterm birth before 36 weeks. © 2017 by the American Institute of Ultrasound in Medicine.

  1. Short-term pressure induced suppression of the short-latency response: a new methodology for investigating stretch reflexes

    DEFF Research Database (Denmark)

    Leukel, Christian; Lundbye-Jensen, Jesper; Gruber, Markus

    2009-01-01

    During experiments involving ischemic nerve block, we noticed that the short-latency response (SLR) of evoked stretches in m. soleus decreased immediately following inflation of a pneumatic cuff surrounding the lower leg. The present study aimed to investigate this short-term effect of pressure......) were recorded. Additionally, stretches were applied with different velocities and amplitudes. Finally, the SLR was investigated during hopping and in two protocols that modified the ability of the muscle-tendon complex distal to the cuff to stretch. All measurements were performed with deflated...

  2. [Clinic-internal and -external factors of length of hospital stay].

    Science.gov (United States)

    Schariatzadeh, R; Imoberdorf, R; Ballmer, P E

    2011-01-19

    In the context of forthcoming initiation of Diagnosis Related Groups (DRG) in Switzerland, the objective of the study was to find factors having an impact on the inpatient's length of hospital stay. The study was performed on two general-medical wards of the Kantonsspital Winterthur, where all admitted patients were included in the study over two months. The various periods of diagnostic and therapeutic management of the patients and all diagnostic and therapeutic measures plus the arrangements after hospitalization were recorded. The determinants influencing the length of hospital stay were classified in clinic-internal or -external. 124 inpatients entered the study. 91 (73.4%) had a length of hospital stay without delay, whereas 33 (26.6%) patients had an extended length of hospital stay. The cumulative length of hospital stay of all patients was 1314 days, whereof 216 days (16.4%) were caused by delays. 67 days were caused by clinic-internal (5.1%) and 149 days by clinic-external factors (11.3%). Delays were substantially more generated by clinic-internal than -external factors. Clinic-internal factors were mainly weekends with interruption of the diagnostic and therapeutic procedures, dead times waiting for diagnostic results and waiting times for consultations. Clinic-external factors were caused by delayed transfer in nursing homes or rehabilitation institutions, waiting for family members for the backhaul and by indetermination of the patient. Also factors relating to the patients' characteristics had an influence on the length of hospital stay. Summing up, a substantial part of the length of hospital stay was caused by delays. However, the many different clinic-internal factors complicate solutions to lower the length of hospital stay. Moreover, factors that cannot be influenced such as waiting for microbiological results, contribute to extended length of hospital stay. Early scheduling of post-hospital arrangements may lower length of hospital stay

  3. Telomeres and replicative senescence: Is it only length that counts?

    Science.gov (United States)

    von Zglinicki, T

    2001-07-26

    Telomeres are well established as a major 'replicometer', counting the population doublings in primary human cell cultures and ultimately triggering replicative senescence. However, neither is the pace of this biological clock inert, nor is there a fixed threshold telomere length acting as the universal trigger of replicative senescence. The available data suggest that opening of the telomeric loop and unscheduled exposure of the single-stranded G-rich telomeric overhang might act like a semaphore to signal senescent cell cycle arrest. Short telomere length, telomeric single-strand breaks, low levels of loop-stabilizing proteins, or other factors may trigger this opening of the loop. Thus, both telomere shortening and the ultimate signalling into senescence are able to integrate different environmental and genetic factors, especially oxidative stress-mediated damage, which might otherwise become a thread to genomic stability.

  4. Scattering Length Scaling Laws for Ultracold Three-Body Collisions

    International Nuclear Information System (INIS)

    D'Incao, J.P.; Esry, B.D.

    2005-01-01

    We present a simple and unifying picture that provides the energy and scattering length dependence for all inelastic three-body collision rates in the ultracold regime for three-body systems with short-range two-body interactions. Here, we present the scaling laws for vibrational relaxation, three-body recombination, and collision-induced dissociation for systems that support s-wave two-body collisions. These systems include three identical bosons, two identical bosons, and two identical fermions. Our approach reproduces all previous results, predicts several others, and gives the general form of the scaling laws in all cases

  5. In vivo myograph measurement of muscle contraction at optimal length

    Directory of Open Access Journals (Sweden)

    Ahmed Aminul

    2007-01-01

    Full Text Available Abstract Background Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Consequently, for clinical testing only semi-quantitative methods have been used. Methods We present a newly developed myograph, an accurate measuring device for muscle contraction, consisting of three elements. Firstly, an element for adjusting the axle of the device and the physiological axis of muscle contraction; secondly, an element to accurately position and reposition the extremity of the muscle; and thirdly, an element for the progressive pre-stretching and isometric locking of the target muscle. Thus it is possible to examine individual in vivo muscles in every pre-stretched, specified position, to maintain constant muscle-length conditions, and to accurately re-establish the conditions of the measurement process at later sessions. Results In a sequence of experiments the force of contraction of the muscle at differing stretching lengths were recorded and the forces determined. The optimum muscle length for maximal force of contraction was established. In a following sequence of experiments with smaller graduations around this optimal stretching length an increasingly accurate optimum muscle length for maximal force of contraction was determined. This optimum length was also accurately re-established at later sessions. Conclusion We have introduced a new technical solution for valid, reproducible in vivo force measurements on every possible point of the stretching curve. Thus it should be possible to study the muscle contraction in vivo to the same level of accuracy as is achieved in tests with in vitro organ preparations.

  6. Length of stay in asylum centres and mental health in asylum seekers: a retrospective study from Denmark

    OpenAIRE

    Hallas, Peter; Hansen, Anne R; St?hr, Mia A; Munk-Andersen, Ebbe; Jorgensen, Henrik L

    2007-01-01

    Abstract Background The length of stay in asylum centres is generally mentioned as a possible health risk to asylum seekers. Medical staff working with asylum seekers has claimed that long lengths of stay in asylum centres might cause or aggravate mental disorders. We used records from a large, multiethnic group of asylum seekers to study if the incidence of mental disorders increased with length of stay. Methods The study population was asylum seekers in Danish asylum centres run by the Dani...

  7. The Preservation and Care of Photographic Records in Heritage ...

    African Journals Online (AJOL)

    It is not unusual for libraries and heritage institutions to include photographic records and collections in their archival holdings. The short history of photography reveals that a range of different materials, chemicals and processes are involved in capturing photographic records, indicating the chemical complexity of the ...

  8. Perioperative and short-term oncological outcomes of single-port surgery for transverse colon cancer.

    Science.gov (United States)

    Tei, Mitsuyoshi; Suzuki, Yozo; Wakasugi, Masaki; Akamatsu, Hiroki

    2017-06-01

    To compare the perioperative and short-term oncological outcomes of patients who underwent single-port surgery (SPS) with those of patients who underwent multi-port surgery (MPS) for transverse colon cancer. The records of consecutive patients who underwent SPS (n = 75) or MPS (n = 41) for transverse colon cancer in our department between January, 2008 and December, 2015 were analyzed retrospectively. Operative times were significantly shorter in the SPS group than in the MPS group (185 vs. 195 min, respectively; P = 0.043). There were no significant differences in operative procedures, blood loss, or extent of lymph node dissection. The rate of postoperative complications was similar in both groups, but the length of hospital stay was significantly shorter in the single-port group than in the multi-port group (8 vs. 11 days, respectively; P transverse colon cancer.

  9. Appointment length, psychiatrists' communication behaviors, and medication management appointment adherence.

    Science.gov (United States)

    Cruz, Mario; Roter, Debra L; Cruz, Robyn F; Wieland, Melissa; Larson, Susan; Cooper, Lisa A; Pincus, Harold Alan

    2013-09-01

    The authors explored the relationship between critical elements of medication management appointments (appointment length, patient-centered talk, and positive nonverbal affect among providers) and patient appointment adherence. The authors used an exploratory, cross-sectional design employing quantitative analysis of 83 unique audio recordings of split treatment medication management appointments for 46 African-American and 37 white patients with 24 psychiatrists at four ambulatory mental health clinics. All patients had a diagnosis of depression. Data collected included demographic information; Patient Health Questionnaire-9 scores for depression severity; psychiatrist verbal and nonverbal communication behaviors during medication management appointments, identified by the Roter Interaction Analysis System during analysis of audio recordings; and appointment adherence. Bivariate analyses were employed to identify covariates that might influence appointment adherence. Generalized estimating equations (GEEs) were employed to assess the relationship between appointment length, psychiatrist patient-centered talk, and positive voice tone ratings and patient appointment adherence, while adjusting for covariates and the clustering of observations within psychiatrists. Wald chi square analyses were used to test whether all or some variables significantly influenced appointment adherence. GEE revealed a significant relationship between positive voice tone ratings and appointment adherence (p=.03). Chi square analyses confirmed the hypothesis of a positive and significant relationship between appointment adherence and positive voice tone ratings (p=.03) but not longer visit length and more patient-centered communication. The nonverbal conveyance of positive affect was associated with greater adherence to medication management appointments by depressed patients. These findings potentially have important implications for communication skills training and adherence research.

  10. Short desynchronization episodes prevail in synchronous dynamics of human brain rhythms.

    Science.gov (United States)

    Ahn, Sungwoo; Rubchinsky, Leonid L

    2013-03-01

    Neural synchronization is believed to be critical for many brain functions. It frequently exhibits temporal variability, but it is not known if this variability has a specific temporal patterning. This study explores these synchronization/desynchronization patterns. We employ recently developed techniques to analyze the fine temporal structure of phase-locking to study the temporal patterning of synchrony of the human brain rhythms. We study neural oscillations recorded by electroencephalograms in α and β frequency bands in healthy human subjects at rest and during the execution of a task. While the phase-locking strength depends on many factors, dynamics of synchrony has a very specific temporal pattern: synchronous states are interrupted by frequent, but short desynchronization episodes. The probability for a desynchronization episode to occur decreased with its duration. The transition matrix between synchronized and desynchronized states has eigenvalues close to 0 and 1 where eigenvalue 1 has multiplicity 1, and therefore if the stationary distribution between these states is perturbed, the system converges back to the stationary distribution very fast. The qualitative similarity of this patterning across different subjects, brain states and electrode locations suggests that this may be a general type of dynamics for the brain. Earlier studies indicate that not all oscillatory networks have this kind of patterning of synchronization/desynchronization dynamics. Thus, the observed prevalence of short (but potentially frequent) desynchronization events (length of one cycle of oscillations) may have important functional implications for the brain. Numerous short desynchronizations (as opposed to infrequent, but long desynchronizations) may allow for a quick and efficient formation and break-up of functionally significant neuronal assemblies.

  11. Study on the crystallization of multiarm stars with a poly(ethyleneimine) core and poly(ϵ-caprolactone) arms of different length

    Energy Technology Data Exchange (ETDEWEB)

    Díaz, Angélica; Bacaicoa, Anna; Casas, Maria Teresa; Franco, Lourdes [Departament d’Enginyeria Química, Universitat Politècnica de Catalunya, Av. Diagonal 647, Barcelona E-08028 (Spain); Serra, Angels [Departament de Química Analítica i Química Orgànica, Universitat Rovira i Virgili. C. Marcel.lí Domingo, s/n. Campus Sescelades, Tarragona 43007 (Spain); Puiggalí, Jordi, E-mail: Jordi.Puiggali@upc.edu [Departament d’Enginyeria Química, Universitat Politècnica de Catalunya, Av. Diagonal 647, Barcelona E-08028 (Spain)

    2015-05-10

    Highlights: • Isothermal crystallization kinetics of multiarm stars. • Influence of the length of poly(ϵ-caprolactone) arms on crystallization kinetics. • Influence of the length of poly(ϵ-caprolactone) arms on secondary nucleation constant. • Crystallization of mixtures of stars having different arm lengths. - Abstract: Crystallization of multiarm star systems constituted by a core of poly(ethyleneimine) (PEI) and arms of poly(ϵ-caprolactone) (PCL) was studied by transmission electron microscopy, calorimetry and optical microscopy techniques. Three systems differing on the degree of polymerization of PCL were studied as well as binary mixtures constituted by systems differing on the length of PCL arms. Samples were able to crystallize from both diluted solutions and the melt state giving rise to well-formed lamellae and spherulites, respectively. Lamellae of samples with large PCL arms were highly regular and corresponded to elongated hexagonal crystals with an aspect ratio that decreased with the length of PCL arms. A significant decrease on equilibrium melting temperatures, degree of crystallinity and glass transition temperature was detected for samples having short PCL arms. Crystallization kinetics were also highly influenced by the length of PCL arms, being both nucleation density and secondary nucleation constant increased as the length of PCL arms decreased. Crystallization of star mixtures having different PCL lengths was determined by the larger arms since they initiated the process and subsequently shorter arms were progressively incorporated. A thermal nucleation was characteristic of multiarm star mixtures due to the different crystallization temperature ranges of samples with large and short PCL arms, whereas samples with a homogeneous arm length rendered an athermal nucleation.

  12. Short rest interval lengths between sets optimally enhance body composition and performance with 8 weeks of strength resistance training in older men.

    Science.gov (United States)

    Villanueva, Matthew G; Lane, Christianne Joy; Schroeder, E Todd

    2015-02-01

    To determine if 8 weeks of periodized strength resistance training (RT) utilizing relatively short rest interval lengths (RI) in between sets (SS) would induce greater improvements in body composition and muscular performance, compared to the same RT program utilizing extended RI (SL). 22 male volunteers (SS: n = 11, 65.6 ± 3.4 years; SL: n = 11, 70.3 ± 4.9 years) were assigned to one of two strength RT groups, following 4 weeks of periodized hypertrophic RT (PHRT): strength RT with 60-s RI (SS) or strength RT with 4-min RI (SL). Prior to randomization, all 22 study participants trained 3 days/week, for 4 weeks, targeting hypertrophy; from week 4 to week 12, SS and SL followed the same periodized strength RT program for 8 weeks, with RI the only difference in their RT prescription. Following PHRT, all study participants experienced increases in lean body mass (LBM) (p body strength (p body fat (p high-intensity strength RT with shortened RI induces significantly greater enhancements in body composition, muscular performance, and functional performance, compared to the same RT prescription with extended RI, in older men. Applied professionals may optimize certain RT-induced adaptations, by incorporating shortened RI.

  13. Wind direction variations in the natural wind – A new length scale

    DEFF Research Database (Denmark)

    Johansson, Jens; Christensen, Silas Sverre

    2018-01-01

    During an observation period of e.g. 10min, the wind direction will differ from its mean direction for short periods of time, and a body of air will pass by from that direction before the direction changes once again. The present paper introduces a new length scale which we have labeled the angular...... length scale. This length scale expresses the average size of the body of air passing by from any deviation of wind direction away from the mean direction. Using metrological observations from two different sites under varying conditions we have shown that the size of the body of air relative to the mean...... size decreases linearly with the deviation from the mean wind direction when the deviation is normalized with the standard deviation of the wind direction. It is shown that this linear variation is independent of the standard deviation of the wind direction, and that the two full-scale data sets follow...

  14. Influence of HPPMS pulse length and inert gas mixture on the properties of (Cr,Al)N coatings

    Energy Technology Data Exchange (ETDEWEB)

    Bagcivan, N.; Bobzin, K. [Surface Engineering Institute, RWTH Aachen University, Kackertstr. 15, D-52072 Aachen (Germany); Grundmeier, G.; Wiesing, M.; Ozcan, O.; Kunze, C. [University of Paderborn, Technical and Macromolecular Chemistry, Warburger Str. 100, D-33098 Paderborn (Germany); Brugnara, R.H., E-mail: brugnara@iot.rwth-aachen.de [Surface Engineering Institute, RWTH Aachen University, Kackertstr. 15, D-52072 Aachen (Germany)

    2013-12-31

    During the production of plastic products by injection molding processes adhesion and abrasion wear as well as corrosion take place in the molding tools. Concerning this, (Cr,Al)N coatings deposited via physical vapor deposition (PVD) have a good potential to be used as protective coatings on injection tools. For an effective protection of coated tools a uniform layer of coating material is also required. In this regard, the HPPMS (high power pulse magnetron sputtering) technology offers possibilities to improve coating thickness uniformity as well as to adapt the chemical and mechanical properties. The present work deals with the investigation of influence of HPPMS pulse length and the argon/krypton ratio in the deposition process on (Cr,Al)N coating properties. For this reason, (Cr,Al)N coatings were deposited with HPPMS pulse length of 40, 80 and 200 μs at constant Ar/Kr ratio (120/80 sccm). The results were compared with a coating deposited with DC Magnetron Sputtering (DC-MS) with the same Ar/Kr ratio. Afterwards, a (Cr,Al)N coating was deposited with constant pulse length (200 μs) without Kr. The chemical composition, morphology and phase composition of the coatings were analyzed by means of EDS (Energy Dispersive Spectroscopy), SEM (Scanning Electron Microscopy) and XRD (X-ray Diffraction), respectively. The composition of the surface near region in the samples was investigated by means of XPS (X-ray Photoelectron Spectroscopy). Mechanical properties were measured by means of nanoindentation. Decreasing of pulse length at constant mean power leads to a considerable increase of cathode current. It could be observed that the deposition rate of the HPPMS process reduces with decreasing pulse length. Nevertheless, short HPPMS pulse lengths and high peak currents lead to an increase of hardness from 25 GPa to 32 GPa while the DC-MS coating displays a hardness of 18 GPa. The use of krypton within the sputter process leads to a marginal increase of the deposition

  15. Development of a 1 GS/s high-resolution transient recorder

    CERN Document Server

    Bartknecht, S; Herrmann, F; Königsmann, K; Lauser, L; Schill, C; Schopferer, S; Wollny, H

    2009-01-01

    With present-day detectors in high energy physics one is often faced with short analog pulses of a few nanoseconds length which may cover large dynamic ranges. In many experiments both amplitude and timing information have to be measured with high accuracy. Additionally, the data rate per readout channel can reach several MHz, which makes high demands on the separation of pile-up pulses. For such applications we have built the GANDALF transient recorder with a resolution of 12bit@1GS/s and an analog bandwidth of 500 MHz. Signals are digitized and processed by fast algorithms to extract pulse arrival times and amplitudes in real-time and to generate experiment trigger signals. With up to 16 analog channels, deep memories and a high data rate interface, this 6U-VME64x/VXS module is not only a dead-time free digitization unit but also has huge numerical capabilities provided by the implementation of a Virtex5-SXT FPGA. Fast algorithms implemented in the FPGA may be used to disentangle possible pile-up pulses and...

  16. Calculating length of gestation from the Society for Assisted Reproductive Technology Clinic Outcome Reporting System (SART CORS) database versus vital records may alter reported rates of prematurity.

    Science.gov (United States)

    Stern, Judy E; Kotelchuck, Milton; Luke, Barbara; Declercq, Eugene; Cabral, Howard; Diop, Hafsatou

    2014-05-01

    To compare length of gestation after assisted reproductive technology (ART) as calculated by three methods from the Society for Assisted Reproductive Technology Clinic Outcome Reporting System (SART CORS) and vital records (birth and fetal death) in the Massachusetts Pregnancy to Early Life Longitudinal Data System (PELL). Historical cohort study. Database linkage analysis. Live or stillborn deliveries. None. ART deliveries were linked to live birth or fetal death certificates. Length of gestation in 7,171 deliveries from fresh autologous ART cycles (2004-2008) was calculated and compared with that of SART CORS with the use of methods: M1 = outcome date - cycle start date; M2 = outcome date - transfer date + 17 days; and M3 = outcome date - transfer date + 14 days + day of transfer. Generalized estimating equation models were used to compare methods. Singleton and multiple deliveries were included. Overall prematurity (delivery 45% of deliveries and by more than 1 week in >22% of deliveries. Each method differed from each other. Estimates of preterm birth in ART vary depending on source of data and method of calculation. Some estimates may overestimate preterm birth rates for ART conceptions. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  17. Short mandible - a possible risk factor for cleft palate with/without a cleft lip

    DEFF Research Database (Denmark)

    Hermann, Nuno Vibe; Darvann, Tron Andre; Ersbøll, Bjarne Kjær

    2014-01-01

    Structured Abstract Objectives To estimate the influence of a short mandible on the risk of developing a cleft palate with/without a cleft lip (CP). Setting and sample population The retrospective sample consisted of 115 2-month-old Danish infants with CP, and 70 control infants with unilateral...... the risk of having a cleft palate. Results The mean mandibular length in the group with CP was about 4mm shorter than in the control group. Odds ratio (OR) was calculated to be 0.58 (95% confidence interval 0.48-0.68), implying that an individual's risk of cleft palate with/without a cleft lip increases...... about 50% per mm decrease in mandibular length. Conclusions A special facial type including a short mandible is a possible risk factor for cleft palate, and it was found that the risk of cleft palate increases 58% per mm decreases in mandibular length....

  18. Comparative evaluation of adequacy of final working length after using Raypex5 or radiography: An in vivo study

    Directory of Open Access Journals (Sweden)

    Deepika Singh

    2015-01-01

    Full Text Available Aim: The aim of this clinical study was to compare the effect of working length (WL determination using electronic apex locator (EAL or WL radiograph on the length adequacy of final WL. Materials and Methods: A total of 153 patients with 153 teeth with single canal were randomized into two groups; in Group 1, the WL was determined by WL radiograph; whereas in Group 2, it was determined by the Raypex5 EAL (VDW, Munich, Germany. Length adequacy was assessed in each group for master cone and categorized into short, acceptable, and over cases. Statistical Analysis Used: The data were statistically analyzed using the Pearson chi-square test at a significance level of P < 0.05. Results: There was no statistically significant difference between the groups in the rates of acceptable (Group 1 = 83.1% and Group 2 = 92.1% and short cases (Group 1 = 3.9% and Group 2 = 5.2%. Over cases in master cone radiography were significantly more in Group 1 (13.1% than Group 2 (2.6% (P = 0.017. Conclusion: The results of our study have shown that under clinical condition, success of Raypex5 was comparable to the radiographic WL determination technique in terms of acceptable and short cases. However, there were significantly lesser over cases in EAL group, showing that EALs can avoid the overestimation of WL.

  19. Leukocyte Telomere Length and Cognitive Function in Older Adults

    Directory of Open Access Journals (Sweden)

    Emily Frith

    2018-04-01

    Full Text Available We evaluated the specific association between leukocyte telomere length and cognitive function among a national sample of the broader U.S. older adult population. Data from the 1999-2002 National Health and Nutrition Examination Survey (NHANES were used to identify 1,722 adults, between 60-85 years, with complete data on selected study variables. DNA was extracted from whole blood via the LTL assay, which is administered using quantitative polymerase chain reaction to measure telomere length relative to standard reference DNA (T/S ratio. Average telomere length was recorded, with two to three assays performed to control for individual variability. The DSST (Digit Symbol Substitution Test was used to assess participant executive cognitive functioning tasks of pairing and free recall. Individuals were excluded if they had been diagnosed with coronary artery disease, congestive heart failure, heart attack or stroke at the baseline assessment. Leukocyte telomere length was associated with higher cognitive performance, independent of gender, race-ethnicity, physical activity status, body mass index and other covariates. In this sample, there was a strong association between LTL and cognition; for every 1 T/S ratio increase in LTL, there was a corresponding 9.9 unit increase in the DSST (β = 9.9; 95% CI: 5.6-14.2; P [JCBPR 2018; 7(1.000: 14-18

  20. Learning From Short Text Streams With Topic Drifts.

    Science.gov (United States)

    Li, Peipei; He, Lu; Wang, Haiyan; Hu, Xuegang; Zhang, Yuhong; Li, Lei; Wu, Xindong

    2017-09-18

    Short text streams such as search snippets and micro blogs have been popular on the Web with the emergence of social media. Unlike traditional normal text streams, these data present the characteristics of short length, weak signal, high volume, high velocity, topic drift, etc. Short text stream classification is hence a very challenging and significant task. However, this challenge has received little attention from the research community. Therefore, a new feature extension approach is proposed for short text stream classification with the help of a large-scale semantic network obtained from a Web corpus. It is built on an incremental ensemble classification model for efficiency. First, more semantic contexts based on the senses of terms in short texts are introduced to make up of the data sparsity using the open semantic network, in which all terms are disambiguated by their semantics to reduce the noise impact. Second, a concept cluster-based topic drifting detection method is proposed to effectively track hidden topic drifts. Finally, extensive studies demonstrate that as compared to several well-known concept drifting detection methods in data stream, our approach can detect topic drifts effectively, and it enables handling short text streams effectively while maintaining the efficiency as compared to several state-of-the-art short text classification approaches.

  1. Pulse length of ultracold electron bunches extracted from a laser cooled gas

    Directory of Open Access Journals (Sweden)

    J. G. H. Franssen

    2017-07-01

    Full Text Available We present measurements of the pulse length of ultracold electron bunches generated by near-threshold two-photon photoionization of a laser-cooled gas. The pulse length has been measured using a resonant 3 GHz deflecting cavity in TM110 mode. We have measured the pulse length in three ionization regimes. The first is direct two-photon photoionization using only a 480 nm femtosecond laser pulse, which results in short (∼15 ps but hot (∼104 K electron bunches. The second regime is just-above-threshold femtosecond photoionization employing the combination of a continuous-wave 780 nm excitation laser and a tunable 480 nm femtosecond ionization laser which results in both ultracold (∼10 K and ultrafast (∼25 ps electron bunches. These pulses typically contain ∼103 electrons and have a root-mean-square normalized transverse beam emittance of 1.5 ± 0.1 nm rad. The measured pulse lengths are limited by the energy spread associated with the longitudinal size of the ionization volume, as expected. The third regime is just-below-threshold ionization which produces Rydberg states which slowly ionize on microsecond time scales.

  2. Long-term and short-term action-effect links and their impact on effect monitoring.

    Science.gov (United States)

    Wirth, Robert; Steinhauser, Robert; Janczyk, Markus; Steinhauser, Marco; Kunde, Wilfried

    2018-04-23

    People aim to produce effects in the environment, and according to ideomotor theory, actions are selected and executed via anticipations of their effects. Further, to ensure that an action has been successful and an effect has been realized, we must be able to monitor the consequences of our actions. However, action-effect links might vary between situations, some might apply for a majority of situations, while others might only apply to special occasions. With a combination of behavioral and electrophysiological markers, we show that monitoring of self-produced action effects interferes with other tasks, and that the length of effect monitoring is determined by both, long-term action-effect links that hold for most situations, and short-term action-effect links that emerge from a current setting. Effect monitoring is fast and frugal when these action-effect links allow for valid anticipation of action effects, but otherwise effect monitoring takes longer and delays a subsequent task. Specific influences of long-term and short-term links on the P1/N1 and P3a further allow to dissect the temporal dynamics of when these links interact for the purpose of effect monitoring. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  3. Effects of Increased Nitrogen Deposition and Rotation Length on Long-Term Productivity of Cunninghamia lanceolata Plantation in Southern China

    Science.gov (United States)

    Zhao, Meifang; Xiang, Wenhua; Tian, Dalun; Deng, Xiangwen; Huang, Zhihong; Zhou, Xiaolu; Peng, Changhui

    2013-01-01

    Cunninghamia lanceolata (Lamb.) Hook. has been widely planted in subtropical China to meet increasing timber demands, leading to short-rotation practices that deplete soil nutrients. However, increased nitrogen (N) deposition offsets soil N depletion. While long-term experimental data investigating the coupled effects related to short rotation practices and increasing N deposition are scarce, applying model simulations may yield insights. In this study, the CenW3.1 model was validated and parameterized using data from pure C. lanceolata plantations. The model was then used to simulate various changes in long-term productivity. Results indicated that responses of productivity of C. lanceolata plantation to increased N deposition were more related to stand age than N addition, depending on the proportion and age of growing forests. Our results have also shown a rapid peak in growth and N dynamics. The peak is reached sooner and is higher under higher level of N deposition. Short rotation lengths had a greater effect on productivity and N dynamics than high N deposition levels. Productivity and N dynamics decreased as the rotation length decreased. Total productivity levels suggest that a 30-year rotation length maximizes productivity at the 4.9 kg N ha−1 year−1 deposition level. For a specific rotation length, higher N deposition levels resulted in greater overall ecosystem C and N storage, but this positive correlation tendency gradually slowed down with increasing N deposition levels. More pronounced differences in N deposition levels occurred as rotation length decreased. To sustain C. lanceolata plantation productivity without offsite detrimental N effects, the appropriate rotation length is about 20–30 years for N deposition levels below 50 kg N ha−1 year−1 and about 15–20 years for N deposition levels above 50 kg N ha−1 year−1. These results highlight the importance of assessing N effects on carbon management and the long-term productivity of

  4. Impact of streamflow data assimilation and length of the verification period on the quality of short-term ensemble hydrologic forecasts

    Science.gov (United States)

    Randrianasolo, A.; Thirel, G.; Ramos, M. H.; Martin, E.

    2014-11-01

    Data assimilation has gained wide recognition in hydrologic forecasting due mainly to its capacity to improve the quality of short-term forecasts. In this study, a comparative analysis is conducted to assess the impact of discharge data assimilation on the quality of streamflow forecasts issued by two different modeling conceptualizations of catchment response. The sensitivity of the performance metrics to the length of the verification period is also investigated. The hydrological modeling approaches are: the coupled physically-based hydro-meteorological model SAFRAN-ISBA-MODCOU, a distributed model with a data assimilation procedure that uses streamflow measurements to assess the initial state of soil water content that optimizes discharge simulations, and the lumped soil moisture-accounting type rainfall-runoff model GRP, which assimilates directly the last observed discharge to update the state of the routing store. The models are driven by the weather ensemble prediction system PEARP of Météo-France, which is based on the global spectral ARPEGE model zoomed over France. It runs 11 perturbed members for a forecast range of 60 h. Forecast and observed data are available for 86 catchments over a 17-month period (March 2005-July 2006) for both models and for 82 catchments over a 52-month period (April 2005-July 2009) for the GRP model. The first dataset is used to investigate the impact of streamflow data assimilation on forecast quality, while the second is used to evaluate the impact of the length of the verification period on the assessment of forecast quality. Forecasts are compared to daily observed discharges and scores are computed for lead times 24 h and 48 h. Results indicate an overall good performance of both hydrological models forced by the PEARP ensemble predictions when the models are run with their data assimilation procedures. In general, when data assimilation is performed, the quality of the forecasts increases: median differences between

  5. Improved Short-Circuit Protection for Power Cells in Series

    Science.gov (United States)

    Davies, Francis

    2008-01-01

    A scheme for protection against short circuits has been devised for series strings of lithium electrochemical cells that contain built-in short-circuit protection devices, which go into a high-resistance, current-limiting state when heated by excessive current. If cells are simply connected in a long series string to obtain a high voltage and a short circuit occurs, whichever short-circuit protection device trips first is exposed to nearly the full string voltage, which, typically, is large enough to damage the device. Depending on the specific cell design, the damage can defeat the protective function, cause a dangerous internal short circuit in the affected cell, and/or cascade to other cells. In the present scheme, reverse diodes rated at a suitably high current are connected across short series sub-strings, the lengths of which are chosen so that when a short-circuit protection device is tripped, the voltage across it does not exceed its rated voltage. This scheme preserves the resetting properties of the protective devices. It provides for bypassing of cells that fail open and limits cell reversal, though not as well as does the more-expensive scheme of connecting a diode across every cell.

  6. Vocal tract length and formant frequency dispersion correlate with body size in rhesus macaques.

    Science.gov (United States)

    Fitch, W T

    1997-08-01

    Body weight, length, and vocal tract length were measured for 23 rhesus macaques (Macaca mulatta) of various sizes using radiographs and computer graphic techniques. linear predictive coding analysis of tape-recorded threat vocalizations were used to determine vocal tract resonance frequencies ("formants") for the same animals. A new acoustic variable is proposed, "formant dispersion," which should theoretically depend upon vocal tract length. Formant dispersion is the averaged difference between successive formant frequencies, and was found to be closely tied to both vocal tract length and body size. Despite the common claim that voice fundamental frequency (F0) provides an acoustic indication of body size, repeated investigations have failed to support such a relationship in many vertebrate species including humans. Formant dispersion, unlike voice pitch, is proposed to be a reliable predictor of body size in macaques, and probably many other species.

  7. Lab-on-a-chip-based PCR-RFLP assay for the confirmed detection of short-length feline DNA in food.

    Science.gov (United States)

    Ali, Md Eaqub; Al Amin, Md; Hamid, Sharifah Bee Abd; Hossain, M A Motalib; Mustafa, Shuhaimi

    2015-01-01

    Wider availability but lack of legal market trades has given feline meat a high potential for use as an adulterant in common meat and meat products. However, mixing of feline meat or its derivatives in food is a sensitive issue, since it is a taboo in most countries and prohibited in certain religions such as Islam and Judaism. Cat meat also has potential for contamination with of severe acute respiratory syndrome, anthrax and hepatitis, and its consumption might lead to an allergic reaction. We developed a very short-amplicon-length (69 bp) PCR assay, authenticated the amplified PCR products by AluI-restriction digestion followed by its separation and detection on a lab-on-a-chip-based automated electrophoretic system, and proved its superiority over the existing long-amplicon-based assays. Although it has been assumed that longer DNA targets are susceptible to breakdown under compromised states, scientific evidence for this hypothesis has been rarely documented. Strong evidence showed that shorter targets are more stable than the longer ones. We confirmed feline-specificity by cross-challenging the primers against 10 different species of terrestrial, aquatic and plant origins in the presence of a 141-bp site of an 18S rRNA gene as a universal eukaryotic control. RFLP analysis separated 43- and 26-bp fragments of AluI-digest in both the gel-image and electropherograms, confirming the original products. The tested detection limit was 0.01% (w/w) feline meat in binary and ternary admixed as well as meatball matrices. Shorter target, better stability and higher sensitivity mean such an assay would be valid for feline identification even in degraded specimens.

  8. [Length of stay in patients admitted for acute heart failure].

    Science.gov (United States)

    Martín-Sánchez, Francisco Javier; Carbajosa, Virginia; Llorens, Pere; Herrero, Pablo; Jacob, Javier; Miró, Òscar; Fernández, Cristina; Bueno, Héctor; Calvo, Elpidio; Ribera Casado, José Manuel

    2016-01-01

    To identify the factors associated with prolonged length of hospital stay in patients admitted for acute heart failure. Multipurpose observational cohort study including patients from the EAHFE registry admitted for acute heart failure in 25 Spanish hospitals. Data were collected on demographic and clinical variables and on the day and place of admission. The primary outcome was length of hospital stay longer than the median. We included 2,400 patients with a mean age of 79.5 (9.9) years; of these, 1,334 (55.6%) were women. Five hundred and ninety (24.6%) were admitted to the short stay unit (SSU), 606 (25.2%) to cardiology, and 1,204 (50.2%) to internal medicine or gerontology. The mean length of hospital stay was 7.0 (RIC 4-11) days. Fifty-eight (2.4%) patients died and 562 (23.9%) were readmitted within 30 days after discharge. The factors associated with prolonged length of hospital stay were chronic pulmonary disease; being a device carrier; having an unknown or uncommon triggering factor; the presence of renal insufficiency, hyponatremia and anaemia in the emergency department; not being admitted to an SSU or the lack of this facility in the hospital; and being admitted on Monday, Tuesday or Wednesday. The factors associated with length of hospital stay≤7days were hypertension, having a hypertensive episode, or a lack of treatment adherence. The area under the curve of the mixed model adjusted to the center was 0.78 (95% CI: 0.76-0.80; p<0.001). A series of factors is associated with prolonged length of hospital stay and should be taken into account in the management of acute heart failure. Copyright © 2016 SESPAS. Published by Elsevier Espana. All rights reserved.

  9. Seismic Site Effects from the Seafloor Motion Recorded by the Short-period Ocean Bottom Seismometers

    Science.gov (United States)

    Lin, J. Y.; Cheng, W. B.; Chin, S. J.; Hsu, S. K.; Dong, J. J.

    2014-12-01

    For decades, it has been mentioned that submarine slope failures are spatially linked to the presence of gas hydrates/gas-charged sediments. When triggered by earthquakes, oversteepen and instable sediments may prompt breakouts of the slopes containing gas hydrates and cause submarine landslides and tsunamis. Widely distributed BSRs have been observed in the area offshore of southwestern Taiwan where the active accretionary complex meets with the passive China continental margin. In the region, large or small scale landslides were also reported based on seismic interpretations. In order to clarify the link between earthquake, landslide and the presence of gas hydrate, we evaluate the response of seafloor sediments in regard to passive dynamic loads. Horizontal-to-vertical (H/V) spectral ratios are used to characterize the local sediment response. Ambient noise as well as distant earthquakes are used as generators of the passive dynamic loads. Based on this study, we aim to characterize the site in terms of its physical properties and the local site effect produced by shallow marine sediments. The results show that the maximum H/V ratios appeared in the range of 5-10 Hz, where the horizontal amplitudes increased by an order of magnitude relative to the vertical amplitude. The stations located in the northwestern part of study area were characterized by another relatively small peak at proximately 2 Hz, which may indicates the presence of a discontinuity of sediments. For most stations, the H/V ratios estimated based on the earthquake (i.e. strong input signal) and noise (background, micro-seismic noise) records were characterized by different pattern. No distinct peak is observed for the H/V pattern calculated during earthquakes. This phenomenon may suggest that no clear sedimentary boundary exist when a stronger motion applies. Estimating H/V spectral ratios of data recorded by the seven short period OBSs (Ocean Bottom Seismometer) deployed in the southwest Taiwan

  10. Length of migration and eating habits of Portuguese university students living in London, United Kingdom.

    Science.gov (United States)

    Vilela, Sofia; Santos, Susana; Padrão, Patrícia; Caraher, Martin

    2014-01-01

    Several studies have pointed adverse effects of long term migration on eating habits. Research is needed to understand if this effect occurs also with a short length of migration, as is the case of international students. Our aim was to evaluate the effect of short and long term migration on eating habits of Portuguese university students. Participants were 46 English and 55 Portuguese students from universities in London, United Kingdom. The findings from this study highlight the difficulties that Portuguese students faced in maintaining a traditional Mediterranean diet after moving to a Northern European environment.

  11. No differences in short-term morbidity and mortality after robot-assisted laparoscopic versus laparoscopic resection for colonic cancer

    DEFF Research Database (Denmark)

    Helvind, Neel Maria; Eriksen, Jens Ravn; Mogensen, Anders Skibsted

    2013-01-01

    BACKGROUND: Robot-assisted laparoscopy has been reported to be a safe and feasible alternative to traditional laparoscopy. The aim of this study was to compare short-term results in patients with colonic cancer who underwent robot-assisted laparoscopic colonic resection (RC) or laparoscopic colonic...... journals. Biochemical markers [C-reactive protein (CRP), hemoglobin, white blood cell count, and thrombocyte count] were recorded before surgery and for the first 3 days after surgery. RESULTS: A total of 101 patients underwent RC and 162 patients underwent LC. There were no significant differences...... in the rate of conversion to open surgery, number of permanent enterostomies, number of intraoperative complications, level of postoperative cellular stress response, number of postoperative complications, length of postoperative hospital stay, or 30-day mortality between the two groups...

  12. Dividing the Force Concept Inventory into two equivalent half-length tests

    Directory of Open Access Journals (Sweden)

    Jing Han

    2015-05-01

    Full Text Available The Force Concept Inventory (FCI is a 30-question multiple-choice assessment that has been a building block for much of the physics education research done today. In practice, there are often concerns regarding the length of the test and possible test-retest effects. Since many studies in the literature use the mean score of the FCI as the primary variable, it would be useful then to have different shorter tests that can produce FCI-equivalent scores while providing the benefits of being quicker to administer and overcoming the test-retest effects. In this study, we divide the 1995 version of the FCI into two half-length tests; each contains a different subset of the original FCI questions. The two new tests are shorter, still cover the same set of concepts, and produce mean scores equivalent to those of the FCI. Using a large quantitative data set collected at a large midwestern university, we statistically compare the assessment features of the two half-length tests and the full-length FCI. The results show that the mean error of equivalent scores between any two of the three tests is within 3%. Scores from all tests are well correlated. Based on the analysis, it appears that the two half-length tests can be a viable option for score based assessment that need to administer tests quickly or need to measure short-term gains where using identical pre- and post-test questions is a concern.

  13. Coronal 2D MR cholangiography overestimates the length of the right hepatic duct in liver transplantation donors

    International Nuclear Information System (INIS)

    Kim, Bohyun; Kim, Kyoung Won; Kim, So Yeon; Park, So Hyun; Lee, Jeongjin; Song, Gi Won; Jung, Dong-Hwan; Ha, Tae-Yong; Lee, Sung Gyu

    2017-01-01

    To compare the length of the right hepatic duct (RHD) measured on rotatory coronal 2D MR cholangiography (MRC), rotatory axial 2D MRC, and reconstructed 3D MRC. Sixty-seven donors underwent coronal and axial 2D projection MRC and 3D MRC. RHD length was measured and categorized as ultrashort (≤1 mm), short (>1-14 mm), and long (>14 mm). The measured length, frequency of overestimation, and the degree of underestimation between two 2D MRC sets were compared to 3D MRC. The length of the RHD from 3D MRC, coronal 2D MRC, and axial 2D MRC showed significant difference (p < 0.05). RHD was frequently overestimated on the coronal than on axial 2D MRC (61.2 % vs. 9 %; p <.0001). On coronal 2D MRC, four (6 %) with short RHD and one (1.5 %) with ultrashort RHD were over-categorized as long RHD. On axial 2D MRC, overestimation was mostly <1 mm (83.3 %), none exceeding 3 mm or over-categorized. The degree of underestimation between the two projection planes was comparable. Coronal 2D MRC overestimates the RHD in liver donors. We suggest adding axial 2D MRC to conventional coronal 2D MRC in the preoperative workup protocol for living liver donors to avoid unexpected confrontation with multiple ductal openings when harvesting the graft. (orig.)

  14. Coronal 2D MR cholangiography overestimates the length of the right hepatic duct in liver transplantation donors

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bohyun [University of Ulsan College of Medicine, Department of Radiology, Asan Medical Center, 88, Olympic-ro 43-gil, Songpa-gu, Seoul (Korea, Republic of); Ajou University School of Medicine, Department of Radiology, Ajou University Medical Center, Suwon (Korea, Republic of); Kim, Kyoung Won; Kim, So Yeon; Park, So Hyun [University of Ulsan College of Medicine, Department of Radiology, Asan Medical Center, 88, Olympic-ro 43-gil, Songpa-gu, Seoul (Korea, Republic of); Lee, Jeongjin [Soongsil University, School of Computer Science and Engineering, Seoul (Korea, Republic of); Song, Gi Won; Jung, Dong-Hwan; Ha, Tae-Yong; Lee, Sung Gyu [University of Ulsan College of Medicine, Department of Surgery, Division of Hepatobiliary and Liver Transplantation Surgery, Asan Medical Center, Seoul (Korea, Republic of)

    2017-05-15

    To compare the length of the right hepatic duct (RHD) measured on rotatory coronal 2D MR cholangiography (MRC), rotatory axial 2D MRC, and reconstructed 3D MRC. Sixty-seven donors underwent coronal and axial 2D projection MRC and 3D MRC. RHD length was measured and categorized as ultrashort (≤1 mm), short (>1-14 mm), and long (>14 mm). The measured length, frequency of overestimation, and the degree of underestimation between two 2D MRC sets were compared to 3D MRC. The length of the RHD from 3D MRC, coronal 2D MRC, and axial 2D MRC showed significant difference (p < 0.05). RHD was frequently overestimated on the coronal than on axial 2D MRC (61.2 % vs. 9 %; p <.0001). On coronal 2D MRC, four (6 %) with short RHD and one (1.5 %) with ultrashort RHD were over-categorized as long RHD. On axial 2D MRC, overestimation was mostly <1 mm (83.3 %), none exceeding 3 mm or over-categorized. The degree of underestimation between the two projection planes was comparable. Coronal 2D MRC overestimates the RHD in liver donors. We suggest adding axial 2D MRC to conventional coronal 2D MRC in the preoperative workup protocol for living liver donors to avoid unexpected confrontation with multiple ductal openings when harvesting the graft. (orig.)

  15. A Monte Carlo simulation method for assessing biotransformation effects on groundwater fuel hydrocarbon plume lengths

    International Nuclear Information System (INIS)

    McNab, W.W. Jr.

    2000-01-01

    Biotransformation of dissolved groundwater hydrocarbon plumes emanating from leaking underground fuel tanks should, in principle, result in plume length stabilization over relatively short distances, thus diminishing the environmental risk. However, because the behavior of hydrocarbon plumes is usually poorly constrained at most leaking underground fuel tank sites in terms of release history, groundwater velocity, dispersion, as well as the biotransformation rate, demonstrating such a limitation in plume length is problematic. Biotransformation signatures in the aquifer geochemistry, most notably elevated bicarbonate, may offer a means of constraining the relationship between plume length and the mean biotransformation rate. In this study, modeled plume lengths and spatial bicarbonate differences among a population of synthetic hydrocarbon plumes, generated through Monte Carlo simulation of an analytical solute transport model, are compared to field observations from six underground storage tank (UST) sites at military bases in California. Simulation results indicate that the relationship between plume length and the distribution of bicarbonate is best explained by biotransformation rates that are consistent with ranges commonly reported in the literature. This finding suggests that bicarbonate can indeed provide an independent means for evaluating limitations in hydrocarbon plume length resulting from biotransformation. (Author)

  16. A near real-time satellite-based global drought climate data record

    International Nuclear Information System (INIS)

    AghaKouchak, Amir; Nakhjiri, Navid

    2012-01-01

    Reliable drought monitoring requires long-term and continuous precipitation data. High resolution satellite measurements provide valuable precipitation information on a quasi-global scale. However, their short lengths of records limit their applications in drought monitoring. In addition to this limitation, long-term low resolution satellite-based gauge-adjusted data sets such as the Global Precipitation Climatology Project (GPCP) one are not available in near real-time form for timely drought monitoring. This study bridges the gap between low resolution long-term satellite gauge-adjusted data and the emerging high resolution satellite precipitation data sets to create a long-term climate data record of droughts. To accomplish this, a Bayesian correction algorithm is used to combine GPCP data with real-time satellite precipitation data sets for drought monitoring and analysis. The results showed that the combined data sets after the Bayesian correction were a significant improvement compared to the uncorrected data. Furthermore, several recent major droughts such as the 2011 Texas, 2010 Amazon and 2010 Horn of Africa droughts were detected in the combined real-time and long-term satellite observations. This highlights the potential application of satellite precipitation data for regional to global drought monitoring. The final product is a real-time data-driven satellite-based standardized precipitation index that can be used for drought monitoring especially over remote and/or ungauged regions. (letter)

  17. Impact of assimilation window length on diurnal features in a Mars atmospheric analysis

    Directory of Open Access Journals (Sweden)

    Yongjing Zhao

    2015-05-01

    Full Text Available Effective simulation of diurnal variability is an important aspect of many geophysical data assimilation systems. For the Martian atmosphere, thermal tides are particularly prominent and contribute much to the Martian atmospheric circulation, dynamics and dust transport. To study the Mars diurnal variability and Mars thermal tides, the Geophysical Fluid Dynamics Laboratory Mars Global Climate Model with the 4D-local ensemble transform Kalman filter (4D-LETKF is used to perform an analysis assimilating spacecraft temperature retrievals. We find that the use of a ‘traditional’ 6-hr assimilation cycle induces spurious forcing of a resonantly enhanced semi-diurnal Kelvin waves represented in both surface pressure and mid-level temperature by forming a wave 4 pattern in the diurnal averaged analysis increment that acts as a ‘topographic’ stationary forcing. Different assimilation window lengths in the 4D-LETKF are introduced to remove the artificially induced resonance. It is found that short assimilation window lengths not only remove the spurious resonance, but also push the migrating semi-diurnal temperature variation at 50 Pa closer to the estimated ‘true’ tides even in the absence of a radiatively active water ice cloud parameterisation. In order to compare the performance of different assimilation window lengths, short-term to mid-range forecasts based on the hour 00 and 12 assimilation are evaluated and compared. Results show that during Northern Hemisphere summer, it is not the assimilation window length, but the radiatively active water ice clouds that influence the model prediction. A ‘diurnal bias correction’ that includes bias correction fields dependent on the local time is shown to effectively reduce the forecast root mean square differences between forecasts and observations, compensate for the absence of water ice cloud parameterisation and enhance Martian atmosphere prediction. The implications of these results for

  18. Independent effects of step length and foot strike pattern on tibiofemoral joint forces during running.

    Science.gov (United States)

    Bowersock, Collin D; Willy, Richard W; DeVita, Paul; Willson, John D

    2017-10-01

    The purpose of this study was to examine the effects of step length and foot strike pattern along with their interaction on tibiofemoral joint (TFJ) and medial compartment TFJ kinetics during running. Nineteen participants ran with a rear foot strike pattern at their preferred speed using a short (-10%), preferred, and long (+10%) step length. These step length conditions were then repeated using a forefoot strike pattern. Regardless of foot strike pattern, a 10% shorter step length resulted in decreased peak contact force, force impulse per step, force impulse per kilometre, and average loading rate at the TFJ and medial compartment, while a 10% increased step length had the opposite effects (all P forefoot strike pattern significantly lowered TFJ and medial compartment TFJ average loading rates compared with a rear foot strike pattern (both forefoot strike pattern produced the greatest reduction in peak medial compartment contact force (P < 0.05). Knowledge of these running modification effects may be relevant to the management or prevention of TFJ injury or pathology among runners.

  19. Data driven discrete-time parsimonious identification of a nonlinear state-space model for a weakly nonlinear system with short data record

    Science.gov (United States)

    Relan, Rishi; Tiels, Koen; Marconato, Anna; Dreesen, Philippe; Schoukens, Johan

    2018-05-01

    Many real world systems exhibit a quasi linear or weakly nonlinear behavior during normal operation, and a hard saturation effect for high peaks of the input signal. In this paper, a methodology to identify a parsimonious discrete-time nonlinear state space model (NLSS) for the nonlinear dynamical system with relatively short data record is proposed. The capability of the NLSS model structure is demonstrated by introducing two different initialisation schemes, one of them using multivariate polynomials. In addition, a method using first-order information of the multivariate polynomials and tensor decomposition is employed to obtain the parsimonious decoupled representation of the set of multivariate real polynomials estimated during the identification of NLSS model. Finally, the experimental verification of the model structure is done on the cascaded water-benchmark identification problem.

  20. Walkway Length Determination for Steady State Walking in Young and Older Adults

    Science.gov (United States)

    Macfarlane, Pamela A.; Looney, Marilyn A.

    2008-01-01

    The primary purpose of this study was to determine acceleration (AC) and deceleration (DC) distances that would accommodate young and older adults walking at their preferred and fast speeds. A secondary purpose was to determine the minimal walkway length needed to record six steady state (SS) steps (three full gait cycles) for younger and older…

  1. Short and inflamed cervix predicts spontaneous preterm birth (COLIBRI study).

    Science.gov (United States)

    Raiche, Evelyne; Ouellet, Annie; Berthiaume, Maryse; Rousseau, Éric; Pasquier, Jean-Charles

    2014-07-01

    To develop a new strategy of predicting spontaneous preterm birth (sPTB) by combination of transvaginal ultrasound (TVUS) assessment and inflammatory proteins detection in vaginal secretions. Prospective study of 87 women referred for cervical length assessment with a standardized TVUS combined to vaginal secretions sampling. Samples were analyzed for presence of 10 cytokines. Main outcome was sPTB (women at a median gestational age of 35.6 weeks of gestation. Short cervix (women with a short inflamed cervix. COLIBRI study used a novel, single-step method of vaginal secretions sampling during TVUS and demonstrated that combination of short cervix and IL-8 in vaginal secretions is a promising sPTB predictive test.

  2. Radiation and propagation of short acoustical pulses from underground explosions

    International Nuclear Information System (INIS)

    Banister, J.R.

    1982-06-01

    Radiation and propagation of short acoustical pulses from underground nuclear explosions were analyzed. The cone of more intense radiation is defined by the ratio of sound speeds in the ground and air. The pressure history of the radiated pulse is a function of the vertical ground-motion history, the range, the burial depth, and the velocity of longitudinal seismic waves. The analysis of short-pulse propagation employed an N-wave model with and without enegy conservation. Short pulses with initial wave lengths less than 100 m are severely attenuated by the energy loss in shocks and viscous losses in the wave interior. The methods developed in this study should be useful for system analysis

  3. Ultralong Radiative States in Hybrid Perovskite Crystals: Compositions for Submillimeter Diffusion Lengths

    KAUST Repository

    Alarousu, Erkki

    2017-08-29

    Organic-inorganic hybrid perovskite materials have recently evolved into the leading candidate solution-processed semiconductor for solar cells due to their combination of desirable optical and charge transport properties. Chief among these properties is the long carrier diffusion length, which is essential to optimizing the device architecture and performance. Herein, we used time-resolved photoluminescence (at low excitation fluence, 10.59 μJ·cm upon two-photon excitation), which is the most accurate and direct approach to measure the radiative charge carrier lifetime and diffusion lengths. Lifetimes of about 72 and 4.3 μs for FAPbBr and FAPbI perovskite single crystals have been recorded, presenting the longest radiative carrier lifetimes reported to date for perovskite materials. Subsequently, carrier diffusion lengths of 107.2 and 19.7 μm are obtained. In addition, we demonstrate the key role of the organic cation units in modulating the carrier lifetime and its diffusion lengths, in which the defect formation energies for FA cations are much higher than those with the MA ones.

  4. A novel ultra-short scanning nuclear microprobe: Design and preliminary results

    International Nuclear Information System (INIS)

    Lebed, S.; Butz, T.; Vogt, J.; Reinert, T.; Spemann, D.; Heitmann, J.; Stachura, Z.; Lekki, J.; Potempa, A.; Styczen, J.; Sulkio-Cleff, B.

    2001-01-01

    The paper describes an optimized scanning nuclear microprobe (MP) with a new ultra-short (total length of 1.85 m) probe forming system based on a divided Russian quadruplet (DRQ) of magnetic quadrupole lenses. Modern electrostatic accelerators have a comparatively high beam brightness of about 10-25 pA/μm 2 /mrad 2 /MeV. This allows the MP proposed to provide a high lateral resolution even with large (1%) parasitic (sextupole and octupole) pole tip field components in all lenses. The features of the design permit the MP operation in the high current and low current modes with a short working distance and inexpensive quadrupole lenses. A new quadrupole doublet design has been developed for the MP. In the present work the calculated features of the new MP are compared with preliminary experimental results obtained with a similar system (total length of 2.3 m) at the INP in Cracow. The new MP is promising for studies of solids or biological samples with high resolutions (0.08-2 μm) in both modes under ambient conditions. A vertical version of the ultra-short MP can be very useful for single ion bombardments of living cells

  5. Hydrolysis of short-chain phosphatidylcholines by bee venom phospholipase A2.

    Science.gov (United States)

    Raykova, D; Blagoev, B

    1986-01-01

    In order to find out the aggregation state of the substrate, preferred by bee venom phospholipase A2 (EC 3.1.1.4), its action on short-chain phosphatidylcholines with two identical (C6-C10) fatty acids has been tested. The rate of hydrolysis as a function of acyl chain length showed a maximum at dioctanoylphosphatidylcholine. The effects of alcohols, NaCl and Triton X-100, which affect the aggregation state of phospholipids in water, were also studied. The addition of n-alcohol led to a significant inhibition of the hydrolysis of the substrates present in micellar form and activated the hydrolysis of substrates which form liposomes. The inhibitory effect increased with increasing length of the aliphatic carbon chain of the alcohol. Triton X-100 at low Triton/phospholipid molar ratios enhanced enzyme activity. These results do not agree with the accepted idea that bee venom phospholipase A2 hydrolyzes short-chain lecithins in their molecularly dispersed form and that micelles cannot act as substrates. The data indicate that short-chain lecithins in the aggregated state are hydrolyzed and that the requirements of bee venom phospholipase A2 for the aggregation state of the substrate are not strict.

  6. Level shifts induced by a short-range potential

    International Nuclear Information System (INIS)

    Karnakov, B.M.; Mur, V.D.

    1984-01-01

    Formulas are derived which express the shifts of levels with energies Esub(n)sup((0)) << rsub(c)sup(-2) in a field Vsub(f)(r) induced by a short-range potential U(r) of radius rsub(c) in terms of the low energy scattering parameters (scattering length and effective radius) with a moment l in the potential. If the interaction between the particle and center is nonresonant, the method developed is identical to perturbation theory on the scattering length. The theory is extended to systems with random degeneracy (Vsub(f) is the Coulomb potential). Formulas describing quasi-intersection of terms are obtained for the case of resonance interaction with the center in a partial wave with l not equal to 0 when energetically close levels are present in both U and Vsub(f). Some features of the level shift are mentioned for the case when the level possesses an anomalously small coupling energy and its coresponding wave function becomes delocalized with decrease of the coupling energy to zero. The problem is discussed of the level shift when the potential Vsub(f) is a potential well surrounded by a weaklyt penetrable barrier. Some applications of the theory to a particle in the field of two short-range potentials or in the field of a short-range and Coulomb centers are considered. Formulas are also obtained for the shifts and widths of the Landau levels and of the shallow level with an arbitrary moment which perturbs the Landau levels

  7. Validation of PC-based Sound Card with Biopac for Digitalization of ECG Recording in Short-term HRV Analysis.

    Science.gov (United States)

    Maheshkumar, K; Dilara, K; Maruthy, K N; Sundareswaren, L

    2016-07-01

    Heart rate variability (HRV) analysis is a simple and noninvasive technique capable of assessing autonomic nervous system modulation on heart rate (HR) in healthy as well as disease conditions. The aim of the present study was to compare (validate) the HRV using a temporal series of electrocardiograms (ECG) obtained by simple analog amplifier with PC-based sound card (audacity) and Biopac MP36 module. Based on the inclusion criteria, 120 healthy participants, including 72 males and 48 females, participated in the present study. Following standard protocol, 5-min ECG was recorded after 10 min of supine rest by Portable simple analog amplifier PC-based sound card as well as by Biopac module with surface electrodes in Leads II position simultaneously. All the ECG data was visually screened and was found to be free of ectopic beats and noise. RR intervals from both ECG recordings were analyzed separately in Kubios software. Short-term HRV indexes in both time and frequency domain were used. The unpaired Student's t-test and Pearson correlation coefficient test were used for the analysis using the R statistical software. No statistically significant differences were observed when comparing the values analyzed by means of the two devices for HRV. Correlation analysis revealed perfect positive correlation (r = 0.99, P < 0.001) between the values in time and frequency domain obtained by the devices. On the basis of the results of the present study, we suggest that the calculation of HRV values in the time and frequency domains by RR series obtained from the PC-based sound card is probably as reliable as those obtained by the gold standard Biopac MP36.

  8. Tactile short-term memory in sensory-deprived individuals.

    Science.gov (United States)

    Papagno, Costanza; Minniti, Giovanna; Mattavelli, Giulia C; Mantovan, Lara; Cecchetto, Carlo

    2017-02-01

    To verify whether loosing a sense or two has consequences on a spared sensory modality, namely touch, and whether these consequences depend on practice or are biologically determined, we investigated 13 deafblind participants, 16 deaf participants, 15 blind participants, and 13 matched normally sighted and hearing controls on a tactile short-term memory task, using checkerboard matrices of increasing length in which half of the squares were made up of a rough texture and half of a smooth one. Time of execution of a fixed matrix, number of correctly reproduced matrices, largest matrix correctly reproduced and tactile span were recorded. The three groups of sensory-deprived individuals did not differ in any measure, while blind and deaf participants outscored controls in all parameters except time of execution; the difference approached significance for deafblind people compared to controls only in one measure, namely correctly reproduced matrices. In blind and deafblind participants, performance negatively correlated with age of Braille acquisition, the older being the subject when acquiring Braille, the lower the performance, suggesting that practice plays a role. However, the fact that deaf participants, who did not share tactile experience, performed similarly to blind participants and significantly better than controls highlights that practice cannot be the only contribution to better tactile memory.

  9. LHC MD 1087: Controlled Longitudinal Emittance Blow-up with Short Bunches

    CERN Document Server

    Timko, Helga; Esteban Muller, Juan; Jaussi, Michael; Lasheen, Alexandre; Shaposhnikova, Elena; CERN. Geneva. ATS Department

    2017-01-01

    The aim of the MD was to study the controlled longitudinal emittance blow-up applied during the ramp with bunches that are slightly shorter than operational. Earlier MDs in 2015 have shown that with a short target bunch length, the blow-up is less controlled and a bifurcation of bunch lengths occurs. The presented measurements show that the bifurcation is independent of the presence of the bunch length feedback, pointing towards an intensity-dependent phenomenon, originating from a synchrotron frequency shift with intensity. Accurate measurements of synchrotron frequency shift with intensity are presented as well. The measurements took place between 22nd August 2016, 19:00 and 23rd August 2016, 04:00.

  10. Design of short Italian sentences to assess near vision performance.

    Science.gov (United States)

    Calossi, Antonio; Boccardo, Laura; Fossetti, Alessandro; Radner, Wolfgang

    2014-01-01

    To develop and validate 28 short Italian sentences for the construction of the Italian version of the Radner Reading Chart to simultaneously measure near visual acuity and reading speed. 41 sentences were constructed in Italian language, following the procedure defined by Radner, to obtain "sentence optotypes" with comparable structure and with the same lexical and grammatical difficulty. Sentences were statistically selected and used in 211 normal, non-presbyopic, native Italian-speaking persons. The most equally matched sentences in terms of reading speed and number of reading errors were selected. To assess the validity of the reading speed results obtained with the 28 selected short sentences, we compared the reading speed and reading errors with the average obtained by reading two long 4th-grade paragraphs (97 and 90 words) under the same conditions. The overall mean reading speed of the tested persons was 189±26wpm. The 28 sentences more similar in terms of reading times were selected, achieving a coefficient of variation (the relative SD) of 2.2%. The reliability analyses yielded an overall Cronbach's alpha coefficient of 0.98. The correlation between the short sentences and the long paragraph was high (r=0.85, P<0.0001). The 28 short single Italian sentences optotypes were highly comparable in syntactical structure, number, position, and length of words, lexical difficulty, and reading length. The resulting Italian Radner Reading Chart is precise (high consistency) and practical (short sentences) and therefore useful for research and clinical practice to simultaneously measure near reading acuity and reading speed. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  11. Interpreting potential markers of storage and rehearsal: Implications for studies of verbal short-term memory and neuropsychological cases.

    Science.gov (United States)

    Wang, Xiaoli; Logie, Robert H; Jarrold, Christopher

    2016-08-01

    Neuropsychological studies of verbal short-term memory have often focused on two signature effects - phonological similarity and word length - the absence of which has been taken to indicate problems in phonological storage and rehearsal respectively. In the present study we present a possible alternative reading of such data, namely that the absence of these effects can follow as a consequence of an individual's poor level of recall. Data from a large normative sample of 251 adult participants were re-analyzed under the assumption that the size of phonological similarity and word length effects are proportional to an individual's overall level of recall. For both manipulations, when proportionalized effects were plotted against memory span, the same function fit the data in both auditory and visual presentation conditions. Furthermore, two additional sets of single-case data were broadly comparable to those that would be expected for an individual's level of verbal short-term memory performance albeit with some variation across tasks. These findings indicate that the absolute magnitude of phonological similarity and word length effects depends on overall levels of recall, and that these effects are necessarily eliminated at low levels of verbal short-term memory performance. This has implications for how one interprets any variation in the size of these effects, and raises serious questions about the causal direction of any relationship between impaired verbal short-term memory and the absence of phonological similarity or word length effects.

  12. Study of injection moulded long glass fibre-reinforced polypropylene and the effect on the fibre length and orientation distribution

    Science.gov (United States)

    Parveeen, B.; Caton-Rose, P.; Costa, F.; Jin, X.; Hine, P.

    2014-05-01

    Long glass fibre (LGF) composites are extensively used in manufacturing to produce components with enhanced mechanical properties. Long fibres with length 12 to 25mm are added to a thermoplastic matrix. However severe fibre breakage can occur in the injection moulding process resulting in shorter fibre length distribution (FLD). The majority of this breakage occurs due to the melt experiencing extreme shear stress during the preparation and injection stage. Care should be taken to ensure that the longer fibres make it through the injection moulding process without their length being significantly degraded. This study is based on commercial 12 mm long glass-fibre reinforced polypropylene (PP) and short glass fibre Nylon. Due to the semi-flexiable behaviour of long glass fibres, the fibre orientation distribution (FOD) will differ from the orientation distribution of short glass fibre in an injection molded part. In order to investigate the effect the change in fibre length has on the fibre orientation distribution or vice versa, FOD data was measured using the 2D section image analyser. The overall purpose of the research is to show how the orientation distribution chnages in an injection moulded centre gated disc and end gated plaque geometry and to compare this data against fibre orientation predictions obtained from Autodesk Moldflow Simulation Insight.

  13. Optical design for increased interaction length in a high gradient dielectric laser accelerator

    OpenAIRE

    Cesar, D.; Maxson, J.; Musumeci, P.; Shen, X.; England, R. J.; Wootton, K. P.

    2018-01-01

    We present a methodology for designing and measuring pulse front tilt in an ultrafast laser for use in dielectric laser acceleration. Previous research into dielectric laser accelerating modules has focused on measuring high accelerating gradients in novel structures, but has done so only for short electron-laser coupling lengths. Here we demonstrate an optical design to extend the laser-electron interaction to 1mm.

  14. The accuracy of axial length measurements in cases of macula-off retinal detachment.

    Science.gov (United States)

    Abou-Shousha, Mohsen; Helaly, Hany Ahmed; Osman, Ihab Mohamed

    2016-04-01

    To assess the accuracy of axial length measurements in cases of macula-off retinal detachment using different methods (optical biometry, A-scan ultrasound, and combined applanation vector-A/B-scan biometry). This prospective clinical study included 100 eyes of 100 patients who underwent vitrectomy alone or phacovitrectomy for macula-off retinal detachment. All patients included signed an informed consent. Preoperative examination of the patients included recording the axial length measurements using optical biometry, A-scan ultrasound, and combined applanation vector-A/B-scan biometry. The mean postoperative IOLMaster axial length after macular reattachment was 26.11 ± 2.91 mm. The mean preoperative IOLMaster axial length with macula-off was 25.32 ± 2.72 mm. The mean preoperative A-scan axial length with macula-off was 25.29 ± 2.80 mm. The mean preoperative vector-A/B-scan axial length with macula-off was 26.03 ± 2.90 mm. The preoperative vector-A/B-scan mean absolute error was 0.59 ± 0.48 D (range, 0.10-2.25 D). Regular methods (optical biometry and A-scan biometry) of measuring the axial length in cases with a detached macula proved to be variable and less accurate. The vector-A/B-scan offered good measurements of the actual axial length in the patients. This was reflected on more accurate postoperative refractive outcome. Copyright © 2016 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  15. Eye movements and word skipping during reading: Effects of word length and predictability

    Science.gov (United States)

    Rayner, Keith; Slattery, Timothy J.; Drieghe, Denis; Liversedge, Simon P.

    2012-01-01

    The extent to which target words were predictable from prior context was varied: half of the target words were predictable and the other half were unpredictable. In addition, the length of the target word varied: the target words were short (4–6 letters), medium (7–9 letters), or long (10–12 letters). Length and predictability both yielded strong effects on the probability of skipping the target words and on the amount of time readers fixated the target words (when they were not skipped). However, there was no interaction in any of the measures examined for either skipping or fixation time. The results demonstrate that word predictability (due to contextual constraint) and word length have strong and independent influences on word skipping and fixation durations. Furthermore, since the long words extended beyond the word identification span, the data indicate that skipping can occur on the basis of partial information in relation to word identity. PMID:21463086

  16. The efficacy of short (6 mm) dental implants with a novel thread design.

    Science.gov (United States)

    Bechara, Soheil; Nimčenko, Tatjana; Kubilius, Ričardas

    2017-01-01

    To assess efficacy of short (6 mm) implants with a novel macrostructure and thread design placed in a compromised bone situations of edentulous posterior regions of maxilla (3-4 mm of bone height under sinus floor) as compared to results of clinical situations treated with simultaneous maxillary sinus grafting and placement of long (≥10 mm) implants of the same company. Clinical cases of conducted clinical study. Patients with compromised bone height in edentulous posterior regions of maxilla were randomly divided into two groups. Short (6mm length) implant treatment conducted in the test group and simultaneous sinus lift with standard length implant placement treatment in the control group. In general implant stability quotient (ISQ) and marginal bone level (MBL) changes values in both groups were comparable. However, significant negative correlation was found between implant's diameter and MBL changes. Implant's length has little if none impact on initial implant anchorage, especially in greatly compromised residual bone situations. Results have confirmed that implant initial stability mainly depends on implant's macro-design and further its development on implant's micro-design: namely, implant diameter rather than length, tapered shape and improved thread design determines primarily acquired mechanical anchorage, while bioactive surface treatment ensures development of biological stability.

  17. The Effects of Cannabis on Inpatient Agitation, Aggression, and Length of Stay.

    Science.gov (United States)

    Johnson, Joseph M; Wu, Chris Y; Winder, Gerald Scott; Casher, Michael I; Marshall, Vincent D; Bostwick, Jolene R

    2016-01-01

    This study examines the association between cannabis use and the hospital course of patients admitted to the psychiatric inpatient unit with a diagnosis of schizophrenia, schizoaffective disorder, or bipolar disorder. Many confounding variables potentially contribute to the clinical presentation of hospitalized patients in the psychiatric unit. Illicit drug use, in particular, has been associated with acute agitation, and questions can be raised as to what lasting effects drug use prior to admission may have throughout a patient's hospital stay. Subjects with a discharge diagnosis of bipolar disorder, schizophrenia, schizoaffective disorder, or psychosis not otherwise specified (N = 201) were retrospectively identified, and those with positive results of urine drug screen for cannabis on admission were compared to negative counterparts. Agitation and aggression were measured using an adaptation of the Excited Component of the Positive and Negative Syndrome Scale (PANSS-EC). These markers were also quantified by comparing charted episodes of restraint and seclusion and administration of as needed medications, such as benzodiazepines and antipsychotics. Positive urine drug screen results for cannabis was correlated with young (p = .001) males (p = .003) with bipolar disorder (p = .009) exhibiting active manic symptoms (p = .003) at the time of admission. Cannabis use was further associated with a shorter length of stay (p = .008), agitation triggering adapted PANSS-EC nursing assessments (p = .029), and oral medications as needed (p = .002) for agitation. Cannabis use, as defined by positive urine drug screen results, was more common in patients with bipolar disorder and was accompanied by a higher incidence of inpatient agitation. Although these patients also had short hospital lengths of stay, there was no clear relationship between level of agitation and length of stay across all patient groups. One possible explanation for patients with bipolar disorder

  18. Morphological observation and length-weight relationship of critically endangered riverine catfish Rita rita (Hamilton).

    Science.gov (United States)

    Amin, M R; Mollah, M F A; Taslima, K; Muhammadullah

    2014-01-15

    The experiment was conducted to investigate the morphological status of the critically endangered riverine catfish Rita rita using morphometric and meristic traits. About 158 species of Rita were collected from the old Brahmaputra river in Mymensingh district and were studied in the laboratory of the Fisheries Biology and Genetics Department, Bangladesh Agricultural University. Measurement of length and weight of Rita were recorded by using measuring scale and electric balance respectively. Significant curvilinear relationship existed between total length and other morphometric characters and between head length and other characters of the head. Relationships between total length and various body measurements of the fish were highly significant (p < 0.01) except the relationship between total length and pelvic fin length of male fish (p < 0.05). In case of meristic characters-dorsal fin rays, pelvic fin rays, pectoral fin rays, anal fin rays, caudal fin rays, number of vertebrae and branchiostegal rays were found to be more or less similar except slight differences. The values of condition factors (k) in the total length body-weight relationships for female and male were found to be 0.41 and 0.38, respectively. The mean values of relative condition factors (kn) were 1.0 and 1.005 for female and male, respectively.

  19. Study on Short-term Variability of Ship Responses in Waves

    DEFF Research Database (Denmark)

    Nielsen, Ulrik Dam; Iseki, Toshio

    2015-01-01

    Short-term variability of ship responses is investigated by cross-spectrum analysis. In a steady state condition, it is well known that a certain length of sampled data is required for stable results of the spectral analysis. However, the phase lag between responses, in terms of the phase angle o...

  20. Study on Short-term Variability of Ship Responses in Waves

    DEFF Research Database (Denmark)

    Iseki, Toshio; Nielsen, Ulrik Dam

    2014-01-01

    Short-term variability of ship responses is investigated from the view point of cross-spectrum analysis. In a steady state condition, it is well known that a certain length of sampled data are required for stable spectral analysis. However, the phase angle of the cross-spectra has not been discus...

  1. Method for single-shot measurement of picosecond laser pulse-lengths without electronic time dispersion

    International Nuclear Information System (INIS)

    Kyrala, G.A.

    1987-01-01

    A two-source shear pattern recording is proposed as a method for single-shot measurement of the pulse shape from nearly monochromatic sources whose pulse lengths are shorter than their coherence times. The basis of this method relies on the assertion that if two identical electromagnetic pulses are recombined with a time delay greater than the sum of their pulse widths, the recordable spatial pattern has no fringes in it. At an arbitrary delay, translated into an actual spatial recording position, the recorded modulated intensity will sample the corresponding laser intensity at that delay time, but with a modulation due to the coherence function of the electromagnetic pulse. Two arrangements are proposed for recording the pattern. The principles, the design parameters, and the methodologies of these arrangements are presented. Resolutions of the configurations and their limitations are given as well

  2. PSPICE simulation of bipolar pulse converter based on short-circuited coaxial transmission line

    International Nuclear Information System (INIS)

    Shi Lei; Fan Yajun

    2010-01-01

    The operating principle of the bipolar pulse converter based on short-circuited coaxial transmission line type is given. The output bipolar pulses are simulated by using PSPICE program on condition of different electric length and different impedance of the short-circuited coaxial transmission line. The bipolar pulses are generated by using unipolar pulse with pulse width of 2 ns in experiment, the experimental result fit well with the simulation result. (authors)

  3. Short Report: Improving Record-Review Surveillance of Young Children with an Autism Spectrum Disorder

    Science.gov (United States)

    Wiggins, Lisa D.; Robins, Diana L.; Yeargin-Allsopp, Marshalyn

    2013-01-01

    Introduction: Records-based autism spectrum disorder surveillance developed at the Centers for Disease Control and Prevention has been extended to younger cohorts, although the utility of additional record sources has not been examined. We therefore conducted a pilot project to describe whether Centers for Disease Control and Prevention…

  4. Ethnic variations in unplanned readmissions and excess length of hospital stay: a nationwide record-linked cohort study

    NARCIS (Netherlands)

    de Bruijne, M.C.; van Rosse, F.; Uiters, E.; Droomers, M.; Suurmond, J.; Stronks, K.; Essink-Bot, M.L.

    2013-01-01

    Background: Studies in the USA have shown ethnic inequalities in quality of hospital care, but in Europe, this has never been analysed. We explored variations in indicators of quality of hospital care by ethnicity in the Netherlands. Methods: We analysed unplanned readmissions and excess length of

  5. Ethnic variations in unplanned readmissions and excess length of hospital stay: a nationwide record-linked cohort study

    NARCIS (Netherlands)

    de Bruijne, Martine C.; van Rosse, Floor; Uiters, Ellen; Droomers, Mariël; Suurmond, Jeanine; Stronks, Karien; Essink-Bot, Marie-Louise

    2013-01-01

    Studies in the USA have shown ethnic inequalities in quality of hospital care, but in Europe, this has never been analysed. We explored variations in indicators of quality of hospital care by ethnicity in the Netherlands. We analysed unplanned readmissions and excess length of stay (LOS) across

  6. Chemotaxonomy in some Mediterranean plants and implications for fossil biomarker records

    Science.gov (United States)

    Norström, Elin; Katrantsiotis, Christos; Smittenberg, Rienk H.; Kouli, Katerina

    2017-12-01

    The increasing utilization of n-alkanes as plant-derived paleo-environmental proxies calls for improved chemotaxonomic control of the modern flora in order to calibrate fossil sediment records to modern analogues. Several recent studies have investigated long-chain n-alkane concentrations and chain-length distributions in species from various vegetation biomes, but up to date, the Mediterranean flora is relatively unexplored in this respect. Here, we analyse the n-alkane concentrations and chain-length distributions in some of the most common species of the modern macchia and phrygana vegetation in south western Peloponnese, Greece. We show that the drought adapted phrygana herbs and shrubs, as well as some of the sclerophyll and gymnosperm macchia components, produce high concentrations of n-alkanes, on average more than double n-alkane production in local wetland reed vegetation. Furthermore, the chain-length distribution in the analysed plants is related to plant functionality, with longer chain lengths associated with higher drought adaptive capacities, probably as a response to long-term evolutionary processes in a moisture limited environment. Furthermore, species with relatively higher average chain lengths (ACL) showed more enriched carbon isotope composition in their tissues (δ13Cplant), suggesting a dual imprint from both physiological and biochemical drought adaptation. The findings have bearings on interpretation of fossil sedimentary biomarker records in the Mediterranean region, which is discussed in relation to a case study from Agios Floros fen, Messenian plain, Peloponnese. The 6000 year long n-alkane record from Agios Floros (ACL, δ13Cwax) is linked to the modern analogue and then evaluated through a comparison with other regional-wide as well as local climate and vegetation proxy-data. The high concentration of long chain n-alkanes in phrygana vegetation suggests a dominating imprint from this vegetation type in sedimentary archives from this

  7. Q-FISH measurement of hepatocyte telomere lengths in donor liver and graft after pediatric living-donor liver transplantation: donor age affects telomere length sustainability.

    Directory of Open Access Journals (Sweden)

    Youichi Kawano

    Full Text Available Along with the increasing need for living-donor liver transplantation (LDLT, the issue of organ shortage has become a serious problem. Therefore, the use of organs from elderly donors has been increasing. While the short-term results of LDLT have greatly improved, problems affecting the long-term outcome of transplant patients remain unsolved. Furthermore, since contradictory data have been reported with regard to the relationship between donor age and LT/LDLT outcome, the question of whether the use of elderly donors influences the long-term outcome of a graft after LT/LDLT remains unsettled. To address whether hepatocyte telomere length reflects the outcome of LDLT, we analyzed the telomere lengths of hepatocytes in informative biopsy samples from 12 paired donors and recipients (grafts of pediatric LDLT more than 5 years after adult-to-child LDLT because of primary biliary atresia, using quantitative fluorescence in situ hybridization (Q-FISH. The telomere lengths in the paired samples showed a robust relationship between the donor and grafted hepatocytes (r = 0.765, p = 0.0038, demonstrating the feasibility of our Q-FISH method for cell-specific evaluation. While 8 pairs showed no significant difference between the telomere lengths for the donor and the recipient, the other 4 pairs showed significantly shorter telomeres in the recipient than in the donor. Multiple regression analysis revealed that the donors in the latter group were older than those in the former (p = 0.001. Despite the small number of subjects, this pilot study indicates that donor age is a crucial factor affecting telomere length sustainability in hepatocytes after pediatric LDLT, and that the telomeres in grafted livers may be elongated somewhat longer when the grafts are immunologically well controlled.

  8. The relationship between telomere length and mortality in chronic obstructive pulmonary disease (COPD.

    Directory of Open Access Journals (Sweden)

    Jee Lee

    Full Text Available Some have suggested that chronic obstructive pulmonary disease (COPD is a disease of accelerated aging. Aging is characterized by shortening of telomeres. The relationship of telomere length to important clinical outcomes such as mortality, disease progression and cancer in COPD is unknown. Using quantitative polymerase chain reaction (qPCR, we measured telomere length of peripheral leukocytes in 4,271 subjects with mild to moderate COPD who participated in the Lung Health Study (LHS. The subjects were followed for approximately 7.5 years during which time their vital status, FEV(1 and smoking status were ascertained. Using multiple regression methods, we determined the relationship of telomere length to cancer and total mortality in these subjects. We also measured telomere length in healthy "mid-life" volunteers and patients with more severe COPD. The LHS subjects had significantly shorter telomeres than those of healthy "mid-life" volunteers (p<.001. Compared to individuals in the 4(th quartile of relative telomere length (i.e. longest telomere group, the remaining participants had significantly higher risk of cancer mortality (Hazard ratio, HR, 1.48; p = 0.0324 and total mortality (HR, 1.29; p = 0.0425. Smoking status did not make a significant difference in peripheral blood cells telomere length. In conclusion, COPD patients have short leukocyte telomeres, which are in turn associated increased risk of total and cancer mortality. Accelerated aging is of particular relevance to cancer mortality in COPD.

  9. Adsorption of short-chain fluids at solid substrates from density functional theory

    International Nuclear Information System (INIS)

    Bryk, P.; Bucior, K.; Sokolowski, S.; Zukocinski, G.

    2005-01-01

    We use microscopic density functional theory to investigate the adsorption of short-chains at solid surfaces. The fluid is modeled as freely-jointed tangent spheres that interact via a short-ranged attractive potential. Within the framework of fundamental measure theory we study how the structure and surface phase behaviour of adsorbed fluid changes when the chain length is increased. We observe that the wetting temperature rescaled by the bulk critical temperature decreases with an increase of the chain length. For longer chains this temperature reaches a plateau. For the surface critical temperature an inverse effect is observed, i.e. the surface critical temperature increases with the chain length and then attains a plateau. Furthermore, we analyze how the layering transitions change with the change of the chain length and with relative strength of the fluid-solid interaction. The critical temperature of the first layering transition, rescaled by the bulk critical temperature increases slightly with an increase of the chain length. We have found that for longer chains the layering transitions within consecutive layers are shifted towards very low temperatures and that their sequence is finally replaced by a single transition. Finally we investigate capillary condensation of chain fluid in slit-like pores. We find that for a fluid of chains consisting of a larger number of segments we observe an inversion effect. Namely, the critical temperature of capillary condensation decreases with increasing pore width for a certain interval of values of the pore width. This anomalous behavior is also influenced by the interaction between molecules and pore walls. (author)

  10. Fabrication of Dry Electrode for Recording Bio-potentials

    International Nuclear Information System (INIS)

    Wang Yu; Yang Jian-Hong; Guo Kai; Pei Wei-Hua; Gui Qiang; Li Xiao-Qian; Chen Hong-Da

    2011-01-01

    Development of minimally invasive dry electrodes for recording biopotentials is presented. The detailed fabrication process is outlined. A dry electrode is formed by a number of microneedles. The lengths of the microneedles are about 150μm and the diameters are about 50μm. The tips of the microneedles are sharp enough to penetrate into the skin. The silver/silver chloride is grown on microneedle arrays and demonstrates good character. The electrocardiogram shows that the dry electrode is suitable for recording biopotentials. (general)

  11. Quantifying Short-Chain Chlorinated Paraffin Congener Groups.

    Science.gov (United States)

    Yuan, Bo; Bogdal, Christian; Berger, Urs; MacLeod, Matthew; Gebbink, Wouter A; Alsberg, Tomas; de Wit, Cynthia A

    2017-09-19

    Accurate quantification of short-chain chlorinated paraffins (SCCPs) poses an exceptional challenge to analytical chemists. SCCPs are complex mixtures of chlorinated alkanes with variable chain length and chlorination level; congeners with a fixed chain length (n) and number of chlorines (m) are referred to as a "congener group" C n Cl m . Recently, we resolved individual C n Cl m by mathematically deconvolving soft ionization high-resolution mass spectra of SCCP mixtures. Here we extend the method to quantifying C n Cl m by introducing C n Cl m specific response factors (RFs) that are calculated from 17 SCCP chain-length standards with a single carbon chain length and variable chlorination level. The signal pattern of each standard is measured on APCI-QTOF-MS. RFs of each C n Cl m are obtained by pairwise optimization of the normal distribution's fit to the signal patterns of the 17 chain-length standards. The method was verified by quantifying SCCP technical mixtures and spiked environmental samples with accuracies of 82-123% and 76-109%, respectively. The absolute differences between calculated and manufacturer-reported chlorination degrees were -0.9 to 1.0%Cl for SCCP mixtures of 49-71%Cl. The quantification method has been replicated with ECNI magnetic sector MS and ECNI-Q-Orbitrap-MS. C n Cl m concentrations determined with the three instruments were highly correlated (R 2 > 0.90) with each other.

  12. A simple device for long-term radar cross section recordings.

    Science.gov (United States)

    Eskelinen, Pekka; Ruoskanen, Jukka; Peltonen, Jouni

    2009-05-01

    A sample and hold circuit with settable delay can be used for recording of radar echo amplitude variations having time scales up to 100 s at the selected range bin in systems utilizing short rf pulses. The design is based on two integrated circuits and gives 1% uncertainty for 70 ns pulses. The key benefit is a real-time display of lengthy amplitude variations because the sample rate is defined by the radar pulse repetition frequency. Additionally we get a reduction in file size at least by the inverse of the radar's duty cycle. Examples of 10 and 100 s recordings with a Ka-band short pulse radar are described.

  13. The application of nonlinear metrics to assess organization differences in short recordings of paroxysmal and persistent atrial fibrillation

    International Nuclear Information System (INIS)

    Alcaraz, Raúl; Rieta, José Joaquín

    2010-01-01

    Atrial fibrillation (AF) is the most common arrhythmia in clinical practice. In the first stages of the disease, AF may terminate spontaneously and it is referred to as paroxysmal AF. The arrhythmia is called persistent AF when external intervention is required to its termination. In the present work, a method to non-invasively assess AF organization has been applied to discern between paroxysmal and persistent AF episodes at any time. Previous works have suggested that the probability of AF termination is inversely related to the number of reentries wandering throughout the atrial tissue. Given that it has also been hypothesized that the number of reentries is directly correlated with AF organization, a fast and robust method able to assess organization differences in AF could be of great interest. In fact, the distinction between paroxysmal and persistent episodes in patients without previously known AF history, making use of short ECG recordings, could contribute to taking earlier decisions on AF management in daily clinical practice, without the need to require 24 h or 48 h Holter recordings. The method was based on a nonlinear regularity index, such as sample entropy (SampEn), and evidenced to be a significant discriminator of the AF type. Its diagnostic accuracy of 91.80% was demonstrated to be superior to previously proposed parameters, such as dominant atrial frequency (DAF) and fibrillatory waves amplitude, and to others analyzed for the first time in this context, such as atrial activity mean power, 3 dB bandwidth around the DAF, first harmonic frequency, harmonic exponential decay, etc. Additionally, according to previous invasive works, paroxysmal AF episodes (0.0716 ± 0.0143) presented lower SampEn values and, consequently, more organized activity, than persistent episodes (0.1080 ± 0.0145)

  14. Effect of marital distance on birth weight and length of offspring

    Directory of Open Access Journals (Sweden)

    Kozieł Sławomir

    2017-09-01

    Full Text Available Marital distance (MD, the geographical distance between birthplaces of spouses, is considered an agent favouring occurrence of heterosis and can be used as a measure of its level. Heterosis itself is a phenomenon of hybrid vigour and seems to be an important factor regulating human growth and development. The main aim of the study is to examine potential effects of MD on birth weight and length of offspring, controlling for socioeconomic status (SES, mother’s age and birth order. Birth weight (2562 boys and 2572 girls and length (2526 boys, 2542 girls of children born in Ostrowiec Swietokrzyski (Poland in 1980, 1983, 1985 and 1988 were recorded during cross-sectional surveys carried out between 1994-1999. Data regarding the socio-demographic variables of families were provided by the parents. Analysis of covariance showed that MD significantly affected both birth weight and length, allowing for sex, birth order, mother’s age and SES of family. For both sexes, a greater marital distance was associated with a higher birth weight and a longer birth length. Our results support the hypothesis that a greater geographical distance between the birth places of parents may contribute to the heterosis effects in offspring. Better birth outcomes may be one of the manifestations of these effects.

  15. Short-term risk of falling after cochlear implantation.

    Science.gov (United States)

    Stevens, Madelyn N; Baudhuin, Jacqueline E; Hullar, Timothy E

    2014-01-01

    Cochlear implantation is a highly effective intervention for hearing loss, but insertion of an implant into the cochlea is often accompanied by loss of residual hearing function. Sometimes, postoperative testing also shows loss of function in the semicircular canals or otolith organs. The effect of this loss on equilibrium, particularly in the short term following surgery, and the risk of falling due to this loss is unknown. We prospectively measured balance in 16 consecutive adult cochlear implant patients before and 2 weeks after surgery. Subjects stood on a foam pad with eyes closed, feet together and arms at the side. The length of time over which this posture could be maintained was recorded up to a maximum value of 30 s indicating normal performance. Ten of 16 subjects reached a maximal time on preoperative testing. Nine of 16 subjects lost balance function after surgery. Four of the 10 subjects with normal preoperative balance function lost function. Subjects older than the age of 60 were more likely to lose balance function than younger subjects. We used previously published values relating balance performance on foam to risk of falling to calculate the fall risk among our subjects. The relative risk of falling increased after surgery by more than threefold in some patients. Imbalance after cochlear implantation may be much more common, particularly in the short term, than previously appreciated. This imbalance is accompanied by an increased risk of falling in many patients. Careful preoperative counseling before implantation and postoperative therapeutic intervention to improve comfort and reduce the chance of falling may be warranted, particularly in patients at a risk for injuries from falls (level of evidence: 2b). © 2014 S. Karger AG, Basel.

  16. Production of carbonaceous materials with various lengths in small spheroidal fullerenes and long CNTs by tunable multi-walled carbon nanotube cutting

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Hoi; Shin, Ueon Sang [Dankook University, Cheonan (Korea, Republic of)

    2016-10-15

    Tunable cutting of multi-walled carbon nanotubes (CNTs) using high pressure homogenizer and/or HNO{sub 3}/H{sub 2}SO{sub 4} solution was accomplished, resulting in the production of short CNTs with minimum length of 35 nm. Field emission scanning electron microscopy (FE-SEM) and Zeta sizer analysis showed significant reduction of CNT length from this tunable cutting (e.g. from long and entangled pristine CNTs at about 20 μm to ≥1000 nm, ⁓400 nm, ⁓200 nm, and ⁓100 nm via high pressure jet-spraying cutting within 5 h, while chemical cutting process using greatly longer hours (48 h) showed a reduction only to about 1000 nm). When CNT sample of average 1000 nm length previously shortened by HNO{sub 3}/H{sub 2}SO{sub 4} was subjected to the high pressure jet-spraying cutting process, the reduction progressed faster (≤1 h), producing ≥35 nm. Fourier transform infrared spectra and thermogravimetric analysis (TGA) indicated restricted formation of hydrophilic functional groups such as carboxylic group and hydroxyl group in the high pressure jet-spraying cutting, whereas an intensive formation of hydrophilic functional groups on the surface of shortened CNT samples was found after chemical cutting. Such short CNT samples would fulfill the requirements for carbonaceous materials with various lengths in small spheroidal fullerenes and long CNTs. The short CNTs produced are promising for scientific and technological applications in many fields such as electronics, diagnostics, pharmaceuticals, biomedical engineering, and environmental or energy industries.

  17. Optimisation of applied field pulses for microwave assisted magnetic recording

    Directory of Open Access Journals (Sweden)

    Simon John Greaves

    2017-05-01

    Full Text Available Grains in a recording medium experience field pulses from a write head during recording. In general, a short head field rise time and a square pulse shape have been viewed as optimal. This work investigates the optimum field pulse shape for microwave assisted magnetic recording on single layer and ECC media. A square pulse was found to give the best recording performance on single layer media, but an initially negative field pulse increasing at a constant rate was more suitable for ECC media.

  18. Association of Leukocyte Telomere Length with Fatigue in Nondisabled Older Adults

    DEFF Research Database (Denmark)

    Bendix, Laila; Thinggaard, Mikael; Kimura, Masayuki

    2014-01-01

    Introduction. Fatigue is often present in older adults with no identified underlying cause. The accruing burden of oxidative stress and inflammation might be underlying factors of fatigue. We therefore hypothesized that leukocyte telomere length (LTL) is relatively short in older adults who...... experience fatigue. Materials and Methods. We assessed 439 older nondisabled Danish twins. LTL was measured using Southern blots of terminal restriction fragments. Fatigue was measured by the Mob-T Scale based on questions on whether the respondents felt fatigued after performing six mobility items. Results...

  19. The influence of spring length on the physical parameters of simple harmonic motion

    International Nuclear Information System (INIS)

    Triana, C A; Fajardo, F

    2012-01-01

    The aim of this work is to analyse the influence of spring length on the simple harmonic motion of a spring-mass system. In particular, we study the effect of changing the spring length on the elastic constant k, the angular frequency ω and the damping factor γ of the oscillations. To characterize the behaviour of these variables we worked with a series of springs of seven different lengths, in which the elastic constant was found by means of the spring-elongation measurement and ω was obtained from the measurement of the oscillation period T of a suspended mass. The oscillatory movement was recorded using a force sensor and the γ value was determined by the fit of the envelope oscillations. Graphical analysis of the results shows that k, ω and γ decrease when the natural spring length increases. This experiment can be performed with equipment normally found in undergraduate physics laboratories. In addition, through graphical analysis students can deduce some relationships between variables that determine the simple harmonic motion behaviour. (paper)

  20. Certificateless short sequential and broadcast multisignature schemes using elliptic curve bilinear pairings

    Directory of Open Access Journals (Sweden)

    SK Hafizul Islam

    2014-01-01

    Full Text Available Several certificateless short signature and multisignature schemes based on traditional public key infrastructure (PKI or identity-based cryptosystem (IBC have been proposed in the literature; however, no certificateless short sequential (or serial multisignature (CL-SSMS or short broadcast (or parallel multisignature (CL-SBMS schemes have been proposed. In this paper, we propose two such new CL-SSMS and CL-SBMS schemes based on elliptic curve bilinear pairing. Like any certificateless public key cryptosystem (CL-PKC, the proposed schemes are free from the public key certificate management burden and the private key escrow problem as found in PKI- and IBC-based cryptosystems, respectively. In addition, the requirements of the expected security level and the fixed length signature with constant verification time have been achieved in our schemes. The schemes are communication efficient as the length of the multisignature is equivalent to a single elliptic curve point and thus become the shortest possible multisignature scheme. The proposed schemes are then suitable for communication systems having resource constrained devices such as PDAs, mobile phones, RFID chips, and sensors where the communication bandwidth, battery life, computing power and storage space are limited.

  1. Length of stay in asylum centres and mental health in asylum seekers: a retrospective study from Denmark.

    Science.gov (United States)

    Hallas, Peter; Hansen, Anne R; Staehr, Mia A; Munk-Andersen, Ebbe; Jorgensen, Henrik L

    2007-10-11

    The length of stay in asylum centres is generally mentioned as a possible health risk to asylum seekers. Medical staff working with asylum seekers has claimed that long lengths of stay in asylum centres might cause or aggravate mental disorders. We used records from a large, multiethnic group of asylum seekers to study if the incidence of mental disorders increased with length of stay. The study population was asylum seekers in Danish asylum centres run by the Danish Red Cross. General medical care was provided by Red Cross staff who could refer selected cases to medical specialists. If an asylum seeker needed more than three specialist consultations for mental illness or five consultations for physical illness the referrals had to be approved by The Danish Immigration Service. Between July 2001 - December 2002 the Red Cross prospectively registered health related data on all new applications (n = 4516) to the Immigration Service regarding referrals to medical specialists. We used these records to analyse the association between length of stay in the asylum centres and overall rate of referral for mental disorders. Data was analysed using weighted linear regression. We found that referrals for mental disorders increased with length of stay in asylum centres in a large, multiethnic population of asylum seekers. The association was found in all the categories of psychiatric illness studied and for a majority of the nationality groups studied. Length of stay in asylum centres was associated with an increase in referrals for mental disorders in a large, multiethnic group of asylum seekers. The present study supports the view that prolonged length of stay in an asylum centre is a risk factor for mental health. The risk of psychiatric illness among asylum seekers should be addressed by political and humanitarian means, giving prevention of illness the highest priority.

  2. Length of stay in asylum centres and mental health in asylum seekers: a retrospective study from Denmark

    Directory of Open Access Journals (Sweden)

    Stæhr Mia A

    2007-10-01

    Full Text Available Abstract Background The length of stay in asylum centres is generally mentioned as a possible health risk to asylum seekers. Medical staff working with asylum seekers has claimed that long lengths of stay in asylum centres might cause or aggravate mental disorders. We used records from a large, multiethnic group of asylum seekers to study if the incidence of mental disorders increased with length of stay. Methods The study population was asylum seekers in Danish asylum centres run by the Danish Red Cross. General medical care was provided by Red Cross staff who could refer selected cases to medical specialists. If an asylum seeker needed more than three specialist consultations for mental illness or five consultations for physical illness the referrals had to be approved by The Danish Immigration Service. Between July 2001 – December 2002 the Red Cross prospectively registered health related data on all new applications (n = 4516 to the Immigration Service regarding referrals to medical specialists. We used these records to analyse the association between length of stay in the asylum centres and overall rate of referral for mental disorders. Data was analysed using weighted linear regression. Results We found that referrals for mental disorders increased with length of stay in asylum centres in a large, multiethnic population of asylum seekers. The association was found in all the categories of psychiatric illness studied and for a majority of the nationality groups studied. Conclusion Length of stay in asylum centres was associated with an increase in referrals for mental disorders in a large, multiethnic group of asylum seekers. The present study supports the view that prolonged length of stay in an asylum centre is a risk factor for mental health. The risk of psychiatric illness among asylum seekers should be addressed by political and humanitarian means, giving prevention of illness the highest priority.

  3. Validation of functional fetal autonomic brain age score fABAS in 5 min short recordings

    International Nuclear Information System (INIS)

    Hoyer, Dirk; Kowalski, Eva-Maria; Schmidt, Alexander; Witte, Otto W; Schneider, Uwe; Schleußner, Ekkehard; Hatzmann, Wolfgang; Grönemeyer, Dietrich HW; Van Leeuwen, Peter

    2015-01-01

    With the objective of evaluating the functional maturation age and developmental disturbances we have previously introduced the fetal autonomic brain age score (fABAS) using 30 min fetal magnetocardiographic recordings (fMCG, Jena). The score is based on heart rate pattern indices that are related to universal principles of developmental biology. The present work aims at the validation of the fABAS methodology on 5 min recordings from an independent database (fMCG, Bochum).We found high agreement of fABAS obtained from Jena normal fetuses (5 min subsets, n  =  364) and Bochum recordings (n  =  322, normal fetuses). fABAS of 48 recordings from fetuses with intra-uterine growth restriction (IUGR, Bochum) was reduced in most of the cases, a result consistent with IUGR fetuses from Jena previously reported. fABAS calculated from 5 min snapshots only partly covers the accuracy when compared to fABAS from 30 min recordings. More precise diagnosis requires longer recordings.fABAS obtained from fMCG recordings is a strong candidate for standardized assessment of functional maturation age and developmental disturbances. Even 5 min recordings seem to be valuable for screening for maturation problems. (paper)

  4. Short Is Beautiful: Dimensionality and Measurement Invariance in Two Length of the Basic Psychological Need Satisfaction at Work Scale

    Directory of Open Access Journals (Sweden)

    Mårten Eriksson

    2018-06-01

    Full Text Available Self-determination theory proposes that all humans have three intrinsic psychological needs: the needs for Autonomy, Competence, and Relatedness. These needs take different forms in different areas of life. The present study examines the psychometric properties of a Swedish version of the Basic Psychological Need Satisfaction at Work (BPNS-W scale. The fit of 10-factor structures previously suggested for related versions of the scale were compared. Cross-sectional data from 1,200 participants were examined in a confirmatory factor analysis framework. Both the original 21-item version and a reduced 12-item version of the BPNS-W were examined. The General Health Questionnaire was used for validation. The results supported a three-factor solution with correlated error variances for the reversed items. Invariance testing of the long and short scales gave best support to the short scale, for which partial scalar invariance was achieved. The external validity of the short scale was supported by a hierarchical regression analysis in which each need made a unique contribution in predicting psychological well-being. In conclusion, the results corroborate a three-factor structure of BPNS-W. Although not perfect the short scale should, it is argued, be preferred over the long version. Directions for the future development of the scale are discussed.

  5. Vapor-liquid equilibrium and critical asymmetry of square well and short square well chain fluids.

    Science.gov (United States)

    Li, Liyan; Sun, Fangfang; Chen, Zhitong; Wang, Long; Cai, Jun

    2014-08-07

    The critical behavior of square well fluids with variable interaction ranges and of short square well chain fluids have been investigated by grand canonical ensemble Monte Carlo simulations. The critical temperatures and densities were estimated by a finite-size scaling analysis with the help of histogram reweighting technique. The vapor-liquid coexistence curve in the near-critical region was determined using hyper-parallel tempering Monte Carlo simulations. The simulation results for coexistence diameters show that the contribution of |t|(1-α) to the coexistence diameter dominates the singular behavior in all systems investigated. The contribution of |t|(2β) to the coexistence diameter is larger for the system with a smaller interaction range λ. While for short square well chain fluids, longer the chain length, larger the contribution of |t|(2β). The molecular configuration greatly influences the critical asymmetry: a short soft chain fluid shows weaker critical asymmetry than a stiff chain fluid with same chain length.

  6. Congenital Short QT Syndrome

    Directory of Open Access Journals (Sweden)

    Charles Antzelevitch

    2004-04-01

    Full Text Available Long QT intervals in the ECG have long been associated with sudden cardiac death. The congenital long QT syndrome was first described in individuals with structurally normal hearts in 1957.1 Little was known about the significance of a short QT interval. In 1993, after analyzing 6693 consecutive Holter recordings Algra et al concluded that an increased risk of sudden death was present not only in patients with long QT interval, but also in patients with short QT interval (<400 ms.2 Because this was a retrospective analysis, further evaluation of the data was not possible. It was not until 2000 that a short-QT syndrome (SQTS was proposed as a new inherited clinical syndrome by Gussak et al.3 The initial report was of two siblings and their mother all of whom displayed persistently short QT interval. The youngest was a 17 year old female presenting with several episodes of paroxysmal atrial fibrillation requiring electrical cardioversion.3 Her QT interval measured 280 msec at a heart rate of 69. Her 21 year old brother displayed a QT interval of 272 msec at a heart rate of 58, whereas the 51 year old mother showed a QT of 260 msec at a heart rate of 74. The authors also noted similar ECG findings in another unrelated 37 year old patient associated with sudden cardiac death.

  7. Minimal impact of an electronic medical records system.

    Science.gov (United States)

    Tall, Jill M; Hurd, Marie; Gifford, Thomas

    2015-05-01

    Electronic medical records (EMRs) implementation in hospitals and emergency departments (EDs) is becoming increasingly more common. The purpose of this study was to determine the impact of an EMR system on patient-related factors that correlate to ED workflow efficiency. A retrospective chart review assessed monthly census reports of all patients who registered and were treated to disposition during conversion from paper charts to an EMR system. The primary outcome measurement was an analysis of the time of registration to discharge or total ED length of stay as well as rate of those who left without being seen, eloped, or left against medical advice. These data were recorded from 3 periods, for 18 months: before installation of the EMR system (pre-EMR), during acclimation to the EMR, and post acclimation (post-EMR). A total of 61626 individual patient records were collected and analyzed. The total ED length of stay across all patient subtypes was not significantly affected by the installation of the hospital-wide EMR system (P = .481); however, a significant decrease was found for patients who were admitted to the hospital from the ED (P .25). Installation of a hospital-wide EMR system had minimal impact on workflow efficiency parameters in an ED. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Value of 18FDG PET-CT in defining the length of esophageal cancer

    International Nuclear Information System (INIS)

    Yuan Shuanghu; Yu Jinming; Yu Yonghua; Yang Xinhua; Chen Shaoqing; Fu Zheng; Yang Guoren; Guo Hongbo; Wang Xiaohang; Zhou Yingzhi

    2006-01-01

    Objective: To assess the value of 18-fluoro-deoxy-glucose positron emission-CT (FDG PET-CT) in defining the length of primary esophageal cancer. Methods: Thirty-two patients had undergone esophagoscopy, esophagography and FDG PET-CT scans one week before esophagectomy. There was one tumor located in the upper thoracic esophagus, 22 in the middle thoracic esophagus, and 9 in the lower thoracic esophagus. The location and length of primary lesion of the tumor was determined by esophagoscopy, esophagography, and FDG PET-CT. The length of the abnormality seen on the CT portion of the PET-CT scan was determined separately and independently by two radiologists. All results were compared with the resected specimen. Results: According to esophagography, CT and PET-CT, all lesion lengths were compared with that of the resected specimen. It was found that the tumor location determined by esophagoscopy was not in accordance with the resected specimen in 2 patients. The mean length of the primary tumor, being from short to long, were (3.8±1.4),(4.1±1.5),(4.4±1.6),(5.3±1.9) and (4.7±1.7) cm, as determined by esophagoscopy, esophagography, CT, actral length of the resected specimen and PET-CT. Compared with the resected specimen,there was obvious difference (P=0.000, 0.007, 0.025, 0.001). Considering that there might be some kind of shrinkage in the resected specimen (about 83.59%, as reported by Ma et al), we rectified the length of resected specimen and compared with other findings again. It was found that insignificant difference existed between PET-CT and rectified length value of the resected specimen (P=0.082). Conclusions: FDG PET-CT is effective in the length determination of primary esophageal cancer. It may be used to determine the length of esophagus to be resected for patients indicated for esophagectomy. It may also be used to accurately delineate the gross tumor volume for patients eligible for radiotherapy. (authors)

  9. Length-Weight Realtionship and Seasonal Distrubition of Magalaspis cordyla (Linnaeus 1758 fish Size frequency Variation from Karachi Coast

    Directory of Open Access Journals (Sweden)

    Quratulan AHMED

    2013-09-01

    Full Text Available The study of seasonal variation in distribution of 167 fishes of magalaspis cordyla from the Karachi fish harbour collected seasonally (pre-monsoon, mon-soon, post-monsoon between September 2011-August 2012. The highest catch of fish (68 was recorded in pre-monsoon season and the lowest catch of fish (47 was recorded in monsoon season. The highest mean length (38.6+ 0.746 and weight (288+ 21.90 was measured during pre-monsoon season and lowest mean length (22.5+ 0.671 and weight (120.5+ 2.73 was measured during mon-soon season. The highest mean condition factor (1.192+ 0.817 and minimum (0.500+ 0.038 was recorded in pre-monsoon season. Fish estimated negative and positive allometric growth because b values larger and less then 3 in pre-monsoon and monsoon season but post-monsoon season showed positive allometric growth because b value larger then 3 in all size classes

  10. Telomere Length and Mortality

    DEFF Research Database (Denmark)

    Kimura, Masayuki; Hjelmborg, Jacob V B; Gardner, Jeffrey P

    2008-01-01

    Leukocyte telomere length, representing the mean length of all telomeres in leukocytes, is ostensibly a bioindicator of human aging. The authors hypothesized that shorter telomeres might forecast imminent mortality in elderly people better than leukocyte telomere length. They performed mortality...

  11. Electron Cloud Cyclotron Resonances in the Presence of a Short-bunch-length Relativistic Beam

    International Nuclear Information System (INIS)

    Celata, Christine; Celata, C.M.; Furman, Miguel A.; Vay, J.-L.; Wu, Jennifer W.

    2008-01-01

    Computer simulations using the 2D code 'POSINST' were used to study the formation of the electron cloud in the wiggler section of the positron damping ring of the International Linear Collider. In order to simulate an x-y slice of the wiggler (i.e., a slice perpendicular to the beam velocity), each simulation assumed a constant vertical magnetic field. At values of the magnetic field where the cyclotron frequency was an integral multiple of the bunch frequency, and where the field strength was less than approximately 0.6 T, equilibrium average electron densities were up to three times the density found at other neighboring field values. Effects of this resonance between the bunch and cyclotron frequency are expected to be non-negligible when the beam bunch length is much less than the product of the electron cyclotron period and the beam

  12. Construction of a flash-photolysis apparatus having a short discharge time

    International Nuclear Information System (INIS)

    Devillers, C.

    1964-01-01

    Flash photolysis aims at reaching directly the primary mechanisms resulting from the action of light on an absorbent matter. This makes it necessary to produce a flash as short and as bright as possible. Our main effort was directed towards reducing the duration of the flash by decreasing the self-inductance of the discharge circuit. A description of this circuit and study of the characteristics of the apparatus are followed by a short description of the two analytical methods: flash spectrography and absorption spectrophotometry at a given wave-length. (author) [fr

  13. Effects of Surface Dipole Lengths on Evaporation of Tiny Water Aggregation

    International Nuclear Information System (INIS)

    Wang Shen; Wan Rongzheng; Fang Haiping; Tu Yusong

    2013-01-01

    Using molecular dynamics simulation, we compared evaporation behavior of a tiny amount of water molecules adsorbed on solid surfaces with different dipole lengths, including surface dipole lengths of 1 fold, 2 folds, 4 folds, 6 folds and 8 folds of 0.14 nm and different charges from 0.1e to 0.9e. Surfaces with short dipole lengths (1-fold system) can always maintain hydrophobic character and the evaporation speeds are not influenced, whether the surface charges are enhanced or weakened; but when surface dipole lengths get to 8 folds, surfaces become more hydrophilic as the surface charge increases, and the evaporation speeds increase gradually and monotonically. By tuning dipole lengths from 1-fold to 8-fold systems, we confirmed non-monotonic variation of the evaporation flux (first increases, then decreases) in 4 fold system with charges (0.1e–0.7e), reported in our previous paper [S. Wang, et al., J. Phys. Chem. B 116 (2012) 13863], and also show the process from the enhancement of this unexpected non-monotonic variation to its vanishment with surface dipole lengths increasing. Herein, we demonstrated two key factors to influence the evaporation flux of a tiny amount of water molecules adsorbed on solid surfaces: the exposed surficial area of water aggregation from where the water molecules can evaporate directly and the attraction potential from the substrate hindering the evaporation. In addition, more interestingly, we showed extra steric effect of surface dipoles on further increase of evaporation flux for 2-folds, 4-folds, 6-folds and 8-folds systems with charges around larger than 0.7e. (The steric effect is first reported by parts of our authors [C. Wang, et al., Sci. Rep. 2 (2012) 358]). This study presents a complete physical picture of the influence of surface dipole lengths on the evaporation behavior of the adsorbed tiny amount of water. (condensed matter: structural, mechanical, and thermal properties)

  14. Simulation Assisted Analysis of the Intrinsic Stiffness for Short DNA Molecules Imaged with Scanning Atomic Force Microscopy.

    Directory of Open Access Journals (Sweden)

    Haowei Wang

    Full Text Available Studying the mechanical properties of short segments of dsDNA can provide insight into various biophysical phenomena, from DNA looping to the organization of nucleosomes. Scanning atomic force microscopy (AFM is able to acquire images of single DNA molecules with near-basepair resolution. From many images, one may use equilibrium statistical mechanics to quantify the intrinsic stiffness (or persistence length of the DNA. However, this approach is highly dependent upon both the correct microscopic polymer model and a correct image analysis of DNA contours. These complications have led to significant debate over the flexibility of dsDNA at short length scales. We first show how to extract accurate measures of DNA contour lengths by calibrating to DNA traces of simulated AFM data. After this calibration, we show that DNA adsorbed on an aminopropyl-mica surface behaves as a worm-like chain (WLC for contour lengths as small as ~20 nm. We also show that a DNA binding protein can modify the mechanics of the DNA from that of a WLC.

  15. On the total number of genes and their length distribution in complete microbial genomes

    DEFF Research Database (Denmark)

    Skovgaard, M; Jensen, L J; Brunak, S

    2001-01-01

    In sequenced microbial genomes, some of the annotated genes are actually not protein-coding genes, but rather open reading frames that occur by chance. Therefore, the number of annotated genes is higher than the actual number of genes for most of these microbes. Comparison of the length distribut......In sequenced microbial genomes, some of the annotated genes are actually not protein-coding genes, but rather open reading frames that occur by chance. Therefore, the number of annotated genes is higher than the actual number of genes for most of these microbes. Comparison of the length...... distribution of the annotated genes with the length distribution of those matching a known protein reveals that too many short genes are annotated in many genomes. Here we estimate the true number of protein-coding genes for sequenced genomes. Although it is often claimed that Escherichia coli has about 4300...... genes, we show that it probably has only approximately 3800 genes, and that a similar discrepancy exists for almost all published genomes....

  16. Short report: Improving record-review surveillance of young children with an autism spectrum disorder.

    Science.gov (United States)

    Wiggins, Lisa D; Robins, Diana L; Yeargin-Allsopp, Marshalyn

    2013-09-01

    Records-based autism spectrum disorder surveillance developed at the Centers for Disease Control and Prevention has been extended to younger cohorts, although the utility of additional record sources has not been examined. We therefore conducted a pilot project to describe whether Centers for Disease Control and Prevention surveillance could identify younger children with an autism spectrum disorder evaluated as part of an ongoing screening study at Georgia State University. In all, 31 families of children who screened positive for autism spectrum disorder and received a clinical evaluation at Georgia State University agreed to participate in the project. Of these, 10 children lived inside the surveillance area and had records abstracted and reviewed for this project. Centers for Disease Control and Prevention surveillance results (i.e. autism spectrum disorder or non-autism spectrum disorder) were compared with Georgia State University evaluation results (i.e. autism spectrum disorder or non-autism spectrum disorder). In all, 4 of the 10 children were diagnosed with an autism spectrum disorder after the Georgia State University evaluation. None of the 4 children with an autism spectrum disorder were identified by current Centers for Disease Control and Prevention surveillance methods but all 4 children were identified by Centers for Disease Control and Prevention surveillance methods when additional record sources were included (i.e. records from the statewide early intervention program and Georgia State University evaluation). These findings suggest that partnering with early intervention programs and encouraging early autism spectrum disorder screening might improve autism spectrum disorder surveillance among young children.

  17. Non-classical polycrystalline silicon thin-film transistor with embedded block-oxide for suppressing the short channel effect

    International Nuclear Information System (INIS)

    Lin, Jyi-Tsong; Huang, Kuo-Dong; Hu, Shu-Fen

    2008-01-01

    In this paper, a polycrystalline silicon (polysilicon) thin-film transistor with a block oxide enclosing body, BTFT, is fabricated and investigated. By utilizing the block-oxide structure of thin-film transistors, the BTFT is shown to suppress the short channel effect. This proposed structure is formed by burying self-aligned oxide spacers along the sidewalls of the source and drain junctions, which reduces the P–N junction area, thereby reducing the junction capacitance and leakage current. Measurements demonstrate that the BTFT eliminates the punch-through effect even down to gate lengths of 1.5 µm, whereas the conventional TFT suffers serious short channel effects at this gate length

  18. Loss factor for short bunches in azimuthally symmetric tapered structures

    Directory of Open Access Journals (Sweden)

    A. Blednykh

    2010-06-01

    Full Text Available We use the program ECHO to study numerically the loss factor of axisymmetric cavities and collimators with and without tapering. We consider a Gaussian driving bunch of length σ, and structures with inner radius b, outer radius d, cavity gap (or collimator inner length g, and taper length L. In all cases we consider a short bunch with σ≪b. For the untapered structures (L=0, in certain regimes, we describe our numerical results using the known expressions for a step transition and for the diffraction model. In addition, we identify new regimes where gb, we present a phenomenological formula which accurately describes the dependence of the loss factor on the parameters σ, b, d, and L. This formula also holds for a tapered cavity with g>d^{2}/σ and d-b>b.

  19. Using short silicon crystals for beam extraction and collimation at U-70 proton synchrotron

    International Nuclear Information System (INIS)

    Afonin, A.G.; Baranov, V.T.; Biryukov, V.M.; Kotov, V.I.; Maisheev, V.A.; Terekhov, V.I.; Troyanov, E.F.; Fedotov, Yu.S.; Chepegin, V.N.; Chesnonkov, Yu.A.

    2002-01-01

    Results of investigations into escape and collimation of proton beams at the IHEP U-70 synchrotron with the application of short flexed silicon monocrystals in length 2 - 4 mm are demonstrated. Good agreement between the measured and calculated efficiency of the flexed crystal is available. Lowering efficiency with the decreasing proton energy is explained by growth of root-mean-square angle of the multiple Coulomb scattering and drop of dechanneling length [ru

  20. Recruitment of single human low-threshold motor units with increasing loads at different muscle lengths.

    Science.gov (United States)

    McNulty, P A; Cresswell, A G

    2004-06-01

    We investigated the recruitment behaviour of low threshold motor units in flexor digitorum superficialis by altering two biomechanical constraints: the load against which the muscle worked and the initial muscle length. The load was increased using isotonic (low load), loaded dynamic (intermediate load) and isometric (high load) contractions in two studies. The initial muscle position reflected resting muscle length in series A, and a longer length with digit III fully extended in series B. Intramuscular EMG was recorded from 48 single motor units in 10 experiments on five healthy subjects, 21 units in series A and 27 in series B, while subjects performed ramp up, hold and ramp down contractions. Increasing the load on the muscle decreased the force, displacement and firing rate of single motor units at recruitment at shorter muscle lengths (Precruitment pattern was observed between loaded dynamic and isotonic contractions, but not between isometric and loaded dynamic contractions. Thus, the recruitment properties of single motor units in human flexor digitorum superficialis are sensitive to changes in both imposed external loads and the initial length of the muscle.

  1. libgapmis: extending short-read alignments.

    Science.gov (United States)

    Alachiotis, Nikolaos; Berger, Simon; Flouri, Tomáš; Pissis, Solon P; Stamatakis, Alexandros

    2013-01-01

    A wide variety of short-read alignment programmes have been published recently to tackle the problem of mapping millions of short reads to a reference genome, focusing on different aspects of the procedure such as time and memory efficiency, sensitivity, and accuracy. These tools allow for a small number of mismatches in the alignment; however, their ability to allow for gaps varies greatly, with many performing poorly or not allowing them at all. The seed-and-extend strategy is applied in most short-read alignment programmes. After aligning a substring of the reference sequence against the high-quality prefix of a short read--the seed--an important problem is to find the best possible alignment between a substring of the reference sequence succeeding and the remaining suffix of low quality of the read--extend. The fact that the reads are rather short and that the gap occurrence frequency observed in various studies is rather low suggest that aligning (parts of) those reads with a single gap is in fact desirable. In this article, we present libgapmis, a library for extending pairwise short-read alignments. Apart from the standard CPU version, it includes ultrafast SSE- and GPU-based implementations. libgapmis is based on an algorithm computing a modified version of the traditional dynamic-programming matrix for sequence alignment. Extensive experimental results demonstrate that the functions of the CPU version provided in this library accelerate the computations by a factor of 20 compared to other programmes. The analogous SSE- and GPU-based implementations accelerate the computations by a factor of 6 and 11, respectively, compared to the CPU version. The library also provides the user the flexibility to split the read into fragments, based on the observed gap occurrence frequency and the length of the read, thereby allowing for a variable, but bounded, number of gaps in the alignment. We present libgapmis, a library for extending pairwise short-read alignments. We

  2. Remembering over the short-term: the case against the standard model.

    Science.gov (United States)

    Nairne, James S

    2002-01-01

    Psychologists often assume that short-term storage is synonymous with activation, a mnemonic property that keeps information in an immediately accessible form. Permanent knowledge is activated, as a result of on-line cognitive processing, and an activity trace is established "in" short-term (or working) memory. Activation is assumed to decay spontaneously with the passage of time, so a refreshing process-rehearsal-is needed to maintain availability. Most of the phenomena of immediate retention, such as capacity limitations and word length effects, are assumed to arise from trade-offs between rehearsal and decay. This "standard model" of how we remember over the short-term still enjoys considerable popularity, although recent research questions most of its main assumptions. In this chapter I review the recent research and identify the empirical and conceptual problems that plague traditional conceptions of short-term memory. Increasingly, researchers are recognizing that short-term retention is cue driven, much like long-term memory, and that neither rehearsal nor decay is likely to explain the particulars of short-term forgetting.

  3. Short forms of the Social Interaction Anxiety Scale and the Social Phobia Scale.

    Science.gov (United States)

    Fergus, Thomas A; Valentiner, David P; McGrath, Patrick B; Gier-Lonsway, Stephanie L; Kim, Hyun-Soo

    2012-01-01

    Mattick and Clarke's (1998) Social Interaction Anxiety Scale (SIAS) and Social Phobia Scale (SPS) are commonly used self-report measures that assess 2 dimensions of social anxiety. Given the need for short, readable measures, this research proposes short forms of both scales. Item-level analyses of readability characteristics of the SIAS and SPS items led to the selection of 6 items from each scale for use in the short forms. The SIAS and SPS short forms had reading levels at approximately the 6th and 5th grade level, respectively. Results using nonclinical (Study 1: N = 469) and clinical (Study 2: N = 145) samples identified these short forms as being factorially sound, possessing adequate internal consistency, and having strong convergence with their full-length counterparts. Moreover, these short forms showed convergence with other measures of social anxiety, showed divergence from measures assessing related constructs, and predicted concurrent interpersonal functioning. Recommendations for the use of these short forms are discussed.

  4. Large-scale, high-resolution multielectrode-array recording depicts functional network differences of cortical and hippocampal cultures.

    Directory of Open Access Journals (Sweden)

    Shinya Ito

    Full Text Available Understanding the detailed circuitry of functioning neuronal networks is one of the major goals of neuroscience. Recent improvements in neuronal recording techniques have made it possible to record the spiking activity from hundreds of neurons simultaneously with sub-millisecond temporal resolution. Here we used a 512-channel multielectrode array system to record the activity from hundreds of neurons in organotypic cultures of cortico-hippocampal brain slices from mice. To probe the network structure, we employed a wavelet transform of the cross-correlogram to categorize the functional connectivity in different frequency ranges. With this method we directly compare, for the first time, in any preparation, the neuronal network structures of cortex and hippocampus, on the scale of hundreds of neurons, with sub-millisecond time resolution. Among the three frequency ranges that we investigated, the lower two frequency ranges (gamma (30-80 Hz and beta (12-30 Hz range showed similar network structure between cortex and hippocampus, but there were many significant differences between these structures in the high frequency range (100-1000 Hz. The high frequency networks in cortex showed short tailed degree-distributions, shorter decay length of connectivity density, smaller clustering coefficients, and positive assortativity. Our results suggest that our method can characterize frequency dependent differences of network architecture from different brain regions. Crucially, because these differences between brain regions require millisecond temporal scales to be observed and characterized, these results underscore the importance of high temporal resolution recordings for the understanding of functional networks in neuronal systems.

  5. Effects of size at birth, childhood growth patterns and growth hormone treatment on leukocyte telomere length.

    Directory of Open Access Journals (Sweden)

    Carolina C J Smeets

    Full Text Available Small size at birth and rapid growth in early life are associated with increased risk of cardiovascular disease in later life. Short children born small for gestational age (SGA are treated with growth hormone (GH, inducing catch-up in length. Leukocyte telomere length (LTL is a marker of biological age and shorter LTL is associated with increased risk of cardiovascular disease.To investigate whether LTL is influenced by birth size, childhood growth and long-term GH treatment.We analyzed LTL in 545 young adults with differences in birth size and childhood growth patterns. Previously GH-treated young adults born SGA (SGA-GH were compared to untreated short SGA (SGA-S, SGA with spontaneous catch-up to a normal body size (SGA-CU, and appropriate for gestational age with a normal body size (AGA-NS. LTL was measured using a quantitative PCR assay.We found a positive association between birth length and LTL (p = 0.04, and a trend towards a positive association between birth weight and LTL (p = 0.08, after adjustments for gender, age, gestational age and adult body size. Weight gain during infancy and childhood and fat mass percentage were not associated with LTL. Female gender and gestational age were positively associated with LTL, and smoking negatively. After adjustments for gender, age and gestational age, SGA-GH had a similar LTL as SGA-S (p = 0.11, SGA-CU (p = 0.80, and AGA-NS (p = 0.30.Larger size at birth is positively associated with LTL in young adulthood. Growth patterns during infancy and childhood are not associated with LTL. Previously GH-treated young adults born SGA have similar LTL as untreated short SGA, SGA with spontaneous catch-up and AGA born controls, indicating no adverse effects of GH-induced catch-up in height on LTL.

  6. Accurate typing of short tandem repeats from genome-wide sequencing data and its applications.

    Science.gov (United States)

    Fungtammasan, Arkarachai; Ananda, Guruprasad; Hile, Suzanne E; Su, Marcia Shu-Wei; Sun, Chen; Harris, Robert; Medvedev, Paul; Eckert, Kristin; Makova, Kateryna D

    2015-05-01

    Short tandem repeats (STRs) are implicated in dozens of human genetic diseases and contribute significantly to genome variation and instability. Yet profiling STRs from short-read sequencing data is challenging because of their high sequencing error rates. Here, we developed STR-FM, short tandem repeat profiling using flank-based mapping, a computational pipeline that can detect the full spectrum of STR alleles from short-read data, can adapt to emerging read-mapping algorithms, and can be applied to heterogeneous genetic samples (e.g., tumors, viruses, and genomes of organelles). We used STR-FM to study STR error rates and patterns in publicly available human and in-house generated ultradeep plasmid sequencing data sets. We discovered that STRs sequenced with a PCR-free protocol have up to ninefold fewer errors than those sequenced with a PCR-containing protocol. We constructed an error correction model for genotyping STRs that can distinguish heterozygous alleles containing STRs with consecutive repeat numbers. Applying our model and pipeline to Illumina sequencing data with 100-bp reads, we could confidently genotype several disease-related long trinucleotide STRs. Utilizing this pipeline, for the first time we determined the genome-wide STR germline mutation rate from a deeply sequenced human pedigree. Additionally, we built a tool that recommends minimal sequencing depth for accurate STR genotyping, depending on repeat length and sequencing read length. The required read depth increases with STR length and is lower for a PCR-free protocol. This suite of tools addresses the pressing challenges surrounding STR genotyping, and thus is of wide interest to researchers investigating disease-related STRs and STR evolution. © 2015 Fungtammasan et al.; Published by Cold Spring Harbor Laboratory Press.

  7. Time recording unit for a neutron time of flight spectrometer

    International Nuclear Information System (INIS)

    Puranik, Praful; Ajit Kiran, S.; Chandak, R.M.; Poudel, S.K.; Mukhopadhyay, R.

    2011-01-01

    Here the architecture and design of Time Recording Unit for a Neutron Time of Flight Spectrometer have been described. The Spectrometer would have an array of 50 Nos. of one meter long linear Position Sensitive Detector (PSD) placed vertically around the sample at a distance of 2000 mm. The sample receives periodic pulsed neutron beam coming through a Fermi chopper. The time and zone of detection of a scattered neutron in a PSD gives information of its flight time and path length, which will be used to calculate its energy. A neutron event zone (position) and time detection module for each PSD provides a 2 bit position/zone code and an event timing pulse. The path length assigned to a neutron detected in a zone (Z1, Z2 etc) in the PSD is the mean path length seen by the neutrons detected in that zone of the PSD. A Time recording unit described here receives event zone code and timing pulse for all the 50 detectors, tags a proper time window code to it, before streaming it to computer for calculation of the energy distribution of neutrons scattered from the sample

  8. The association between length of emergency department boarding and mortality.

    Science.gov (United States)

    Singer, Adam J; Thode, Henry C; Viccellio, Peter; Pines, Jesse M

    2011-12-01

    Emergency department (ED) boarding has been associated with several negative patient-oriented outcomes, from worse satisfaction to higher inpatient mortality rates. The current study evaluates the association between length of ED boarding and outcomes. The authors expected that prolonged ED boarding of admitted patients would be associated with higher mortality rates and longer hospital lengths of stay (LOS). This was a retrospective cohort study set at a suburban academic ED with an annual ED census of 90,000 visits. Consecutive patients admitted to the hospital from the ED and discharged between October 2005 and September 2008 were included. An electronic medical record (EMR) system was used to extract patient demographics, ED disposition (discharge, admit to floor), ED and hospital LOS, and in-hospital mortality. Boarding was defined as ED LOS 2 hours or more after decision for admission. Descriptive statistics were used to evaluate the association between length of ED boarding and hospital LOS, subsequent transfer to an intensive care unit (ICU), and mortality controlling for comorbidities. There were 41,256 admissions from the ED. Mortality generally increased with increasing boarding time, from 2.5% in patients boarded less than 2 hours to 4.5% in patients boarding 12 hours or more (p boarding time (p boarded for more than 24 hours. The increases were still apparent after adjustment for comorbid conditions and other factors. Hospital mortality and hospital LOS are associated with length of ED boarding. © 2011 by the Society for Academic Emergency Medicine.

  9. Phase conjugation of speckle-inhomogeneous radiation in a holographic Nd:YAG laser with a short thermal hologram

    International Nuclear Information System (INIS)

    Yarovoi, V V; Kirsanov, A V

    2002-01-01

    A model of the so-called short hologram, which does not exhibit in-depth diffraction deformation of the fine speckle pattern of the recording fields, is studied. The investigation is performed by the example of a thermal hologram recorded by two speckle waves, which is the output mirror of a ring laser produced as a result of this recording. It is shown that the ability of this short hologram to select a wave conjugated to a speckle signal in the mode of the holographic laser depends both on the degree of mutual mixing of the speckles of recording beams in the hologram volume and on the effects of its saturation by the beams. The maximum accuracy of phase conjugation of speckle radiation in the holographic Nd:YAG laser achieved upon the best selection of the conjugate wave by the short thermal hologram was 93%. (nonlinear optical phenomena)

  10. DNA interactions with a Methylene Blue redox indicator depend on the DNA length and are sequence specific.

    Science.gov (United States)

    Farjami, Elaheh; Clima, Lilia; Gothelf, Kurt V; Ferapontova, Elena E

    2010-06-01

    A DNA molecular beacon approach was used for the analysis of interactions between DNA and Methylene Blue (MB) as a redox indicator of a hybridization event. DNA hairpin structures of different length and guanine (G) content were immobilized onto gold electrodes in their folded states through the alkanethiol linker at the 5'-end. Binding of MB to the folded hairpin DNA was electrochemically studied and compared with binding to the duplex structure formed by hybridization of the hairpin DNA to a complementary DNA strand. Variation of the electrochemical signal from the DNA-MB complex was shown to depend primarily on the DNA length and sequence used: the G-C base pairs were the preferential sites of MB binding in the duplex. For short 20 nts long DNA sequences, the increased electrochemical response from MB bound to the duplex structure was consistent with the increased amount of bound and electrochemically readable MB molecules (i.e. MB molecules that are available for the electron transfer (ET) reaction with the electrode). With longer DNA sequences, the balance between the amounts of the electrochemically readable MB molecules bound to the hairpin DNA and to the hybrid was opposite: a part of the MB molecules bound to the long-sequence DNA duplex seem to be electrochemically mute due to long ET distance. The increasing electrochemical response from MB bound to the short-length DNA hybrid contrasts with the decreasing signal from MB bound to the long-length DNA hybrid and allows an "off"-"on" genosensor development.

  11. Genetic Mutations, Birth Lengths, Weights and Head Circumferences of Children with IGF-I Receptor Defects. Comparison with other Congenital Defects in the GH/IGF-I axis.

    Science.gov (United States)

    Essakow, Jenna Lee; Lauterpacht, Aharon; Lilos, Pearl; Kauli, Rivka; Laron, Zvi

    2016-09-01

    In recent years more and more genetic defects along the GHRH-GH-IGF-I axis have been reported. Mutations of the IGF-I receptor (R) are a rare abnormality of whom only the heterozygote progenies survive. To summarize, from the literature, data on birth length, weight and head circumference of neonates with IGF-I-R mutations, and to correlate the data with that of other types of mutations in the GH/IGF-I axis. Sixty seven neonates from 24 published articles were included and forty seven different mutations of the IGF-I (R) located on chromosome 15 have been identified. Mean (±SD) birth length (BL), available for 26, (10 M, 16F) neonates with a gestational age of 34-41weeks, was 44.2±4cm; one was premature (30cm at 31 weeks). There was a significant correlation between birth length and gestational age (GA) r=0.71 (p>.001). Mean birth weight (BW) of 41 neonates (18M, 23F) was 2388±743gr. Two premature neonates weighed 650gr and 950gr respectively. The BW correlated significantly with gestational age, (males: r=0.68; p=0.007, females: r=0.49; p=0.024). The BMI of 25 neonates ranged from 6 to 13. In 22 records marked microcephaly was ascertained or stated. Nine of 16 mothers were short (133 -148cm), m±SD = 150.5±7.3cm. Copyright© of YS Medical Media ltd.

  12. Retrospective analysis of survival rates and marginal bone loss on short implants in the mandible.

    Science.gov (United States)

    Draenert, Florian G; Sagheb, Keyvan; Baumgardt, Katharina; Kämmerer, Peer W

    2012-09-01

    Short implants have become an interesting alternative to bone augmentation in dental implantology. Design of shorter implants and longer surveillance times are a current research issue. The goal of this study was to show the survival rates of short implants below 9 mm in the partly edentulous mandibular premolar and molar regions with fixed prosthetics. Marginal vertical and 2D bone loss was evaluated additionally. Different implant designs are orientationally evaluated. A total of 247 dental implants with fixed prosthetics (crowns and bridges) in the premolar and molar region of the mandible were evaluated; 47 implants were 9 mm or shorter. Patient data were evaluated to acquire implant survival rates, implant diameter, gender and age. Panoramic X-rays were analysed for marginal bone loss. Average surveillance time was 1327 days. Cumulative survival rate (CSR) of short implants was 98% (1 implants lost) compared to 94% in the longer implants group without significance. Thirty-five of the short implants were Astratech (0 losses) and 12 were Camlog Screw Line Promote Plus (1 loss). Early vertical and two-dimensional marginal bone loss was not significantly different in short and regular length implant group with an average of 0.6 mm and 0.7 mm(2) in short implants over the observation period. Within the limitations of this study, we conclude that short implants with a length of 9 mm or less have equal survival rates compared with longer implants over the observation period of 1-3 years. © 2011 John Wiley & Sons A/S.

  13. Full micromagnetics of recording on patterned media

    International Nuclear Information System (INIS)

    Fidler, J.; Schrefl, T.; Suess, D.; Ertl, O.; Kirschner, M.; Hrkac, G.

    2006-01-01

    Numerical micromagnetics of the bit writing process revealed the theoretical limits for remanence, coercive field, switching behaviour at a short time scale of less than 1 ns for patterned recording media. We discuss our recent results concerning the influence of the granular microstructure on the fast switching processes of typical CoCrPtX, FePt and CoPd thin films used for high density magnetic recording with longitudinal and perpendicular anisotropy. In detail, we will show that the degree of the exchange coupling between neighbouring grains, the grain size and its distribution and the offset between recording head and bit structure finally control the magnetization reversal properties of the individual bits

  14. Correlated evolution of sternal keel length and ilium length in birds

    Directory of Open Access Journals (Sweden)

    Tao Zhao

    2017-07-01

    Full Text Available The interplay between the pectoral module (the pectoral girdle and limbs and the pelvic module (the pelvic girdle and limbs plays a key role in shaping avian evolution, but prior empirical studies on trait covariation between the two modules are limited. Here we empirically test whether (size-corrected sternal keel length and ilium length are correlated during avian evolution using phylogenetic comparative methods. Our analyses on extant birds and Mesozoic birds both recover a significantly positive correlation. The results provide new evidence regarding the integration between the pelvic and pectoral modules. The correlated evolution of sternal keel length and ilium length may serve as a mechanism to cope with the effect on performance caused by a tradeoff in muscle mass between the pectoral and pelvic modules, via changing moment arms of muscles that function in flight and in terrestrial locomotion.

  15. The impact of coherent synchrotron radiation on the beam transport of short bunches

    International Nuclear Information System (INIS)

    Li, R.

    1999-01-01

    Designs for next-generation accelerator, such as future linear colliders and short-wavelength FEL drivers, require beams of short (mm-length or smaller) bunches and high charge (nC-regime). As such a high charge microbunch traverses magnetic bends, the curvature effect on the bunch self-interaction, by way of coherent synchrotron radiation (CSR) and space charge force, may cause serious emittance degradation. This impact of CSR on the beam transport of short bunches has raised significant concern in the design of future machines and led to extensive investigations. This paper reviews some of the recent progress in the understanding of the CSR effect, presents analysis of and computational work on the CSR impact on short bunch transport, and addresses remaining issues

  16. On the total number of genes and their length distribution in complete microbial genomes

    DEFF Research Database (Denmark)

    Skovgaard, Marie; Jensen, L.J.; Brunak, Søren

    2001-01-01

    In sequenced microbial genomes, some of the annotated genes are actually not protein-coding genes, but rather open reading frames that occur by chance. Therefore, the number of annotated genes is higher than the actual number of genes for most of these microbes. Comparison of the length...... distribution of the annotated genes with the length distribution of those matching a known protein reveals that too many short genes are annotated in many genomes. Here we estimate the true number of protein-coding genes for sequenced genomes. Although it is often claimed that Escherichia coli has about 4300...... genes, we show that it probably has only similar to 3800 genes, and that a similar discrepancy exists for almost all published genomes....

  17. Fundamental length

    International Nuclear Information System (INIS)

    Pradhan, T.

    1975-01-01

    The concept of fundamental length was first put forward by Heisenberg from purely dimensional reasons. From a study of the observed masses of the elementary particles known at that time, it is sumrised that this length should be of the order of magnitude 1 approximately 10 -13 cm. It was Heisenberg's belief that introduction of such a fundamental length would eliminate the divergence difficulties from relativistic quantum field theory by cutting off the high energy regions of the 'proper fields'. Since the divergence difficulties arise primarily due to infinite number of degrees of freedom, one simple remedy would be the introduction of a principle that limits these degrees of freedom by removing the effectiveness of the waves with a frequency exceeding a certain limit without destroying the relativistic invariance of the theory. The principle can be stated as follows: It is in principle impossible to invent an experiment of any kind that will permit a distintion between the positions of two particles at rest, the distance between which is below a certain limit. A more elegant way of introducing fundamental length into quantum theory is through commutation relations between two position operators. In quantum field theory such as quantum electrodynamics, it can be introduced through the commutation relation between two interpolating photon fields (vector potentials). (K.B.)

  18. Buckling Experiment on Anisotropic Long and Short Cylinders

    Directory of Open Access Journals (Sweden)

    Atsushi Takano

    2016-07-01

    Full Text Available A buckling experiment was performed on anisotropic, long and short cylinders with various radius-to-thickness ratios. The 13 cylinders had symmetric and anti-symmetric layups, were between 2 and 6 in terms of the length-to-radius ratio, between 154 and 647 in radius-to-thickness ratio, and made of two kinds of carbon fiber reinforced plastic (CFRP prepreg with high or low fiber modulus. The theoretical buckling loads for the cylinders were calculated from the previously published solution by using linear bifurcation theory considering layup anisotropy and transverse shear deformation and by using deep shell theory to account for the effect of length and compared with the test results. The theoretical buckling loads for the cylinders were calculated from the previously published solution by using linear bifurcation theory considering layup anisotropy and transverse shear deformation and by using deep shell theory to account for the effect of length. The knockdown factor, defined as the ratio of the experimental value to the theoretical value, was found to be between 0.451 and 0.877. The test results indicated that a large length-to-radius ratio reduces the knockdown factor, but the radius-to-thickness ratio and other factors do not affect it.

  19. Drive-based recording analyses at >800 Gfc/in2 using shingled recording

    International Nuclear Information System (INIS)

    William Cross, R.; Montemorra, Michael

    2012-01-01

    Since the introduction of perpendicular recording, conventional perpendicular scaling has enabled the hard disk drive industry to deliver products ranging from ∼130 to well over 500 Gb/in 2 in a little over 4 years. The incredible areal density growth spurt enabled by perpendicular recording is now endangered by an inability to effectively balance writeability with erasure effects at the system level. Shingled magnetic recording (SMR) offers an effective means to continue perpendicular areal density growth using conventional heads and tuned media designs. The use of specially designed edge-write head structures (also known as 'corner writers') should further increase the AD gain potential for shingled recording. In this paper, we will demonstrate the drive-based recording performance characteristics of a shingled recording system at areal densities in excess of 800 Gb/in 2 using a conventional head. Using a production drive base, developmental heads/media and a number of sophisticated analytical routines, we have studied the recording performance of a shingled magnetic recording subsystem. Our observations confirm excellent writeability in excess of 400 ktpi and a perpendicular system with acceptable noise balance, especially at extreme ID and OD skews where the benefits of SMR are quite pronounced. We believe that this demonstration illustrates that SMR is not only capable of productization, but is likely the path of least resistance toward production drive areal density closer to 1 Tb/in 2 and beyond. - Research highlights: → Drive-based recording demonstrations at 805 Gf/in 2 has been demonstrated using both 95 and 65 mm drive platforms at roughly 430 ktpi and 1.87 Mfci. → Limiting factors for shingled recording include side reading, which is dominated by the reader crosstrack skirt profile, MT10 being a representative metric. → Media jitter and associated DC media SNR further limit areal density, dominated by crosstrack transition curvature, downtrack

  20. Multiple-bunch-length operating mode design for a storage ring using hybrid low alpha and harmonic cavity method

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Weiwei, E-mail: gaomqr@mail.ustc.edu.cn [College of Mathematics and Physics, Fujian University of Technology, Fuzhou 350118 (China); Wang, Lin; Li, Heting [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029 (China)

    2017-03-11

    In this paper we design a simultaneous three bunch length operating mode at the HLS-II (Hefei Light Source II) storage ring by installing two harmonic cavities and minimizing the momentum compaction factor. The short bunches (2.6 mm) presented in this work will meet the requirement of coherent millimeter-wave and sub-THz radiation experiments, while the long bunches (20 mm) will efficiently increase the total beam current. Therefore, this multiple-bunch-length operating mode allows present synchrotron users and coherent millimeter-wave users (or sub THz users) to carry out their experiments simultaneously. Since the relatively low energy characteristic of HLS-II we achieve the multiple-bunch-length operating mode without multicell superconducting RF cavities, which is technically feasible.

  1. Telomerase and Tel1p Preferentially Associate with Short Telomeres in S. cerevisiae

    Science.gov (United States)

    Sabourin, Michelle; Tuzon, Creighton T.; Zakian, Virginia A.

    2009-01-01

    SUMMARY In diverse organisms, telomerase preferentially elongates short telomeres. We generated a single short telomere in otherwise wild-type (WT) S. cerevisiae cells. The binding of the positive regulators Ku and Cdc13p was similar at short and WT-length telomeres. The negative regulators Rif1p and Rif2p were present at the short telomere, although Rif2p levels were reduced. Two telomerase holoenzyme components, Est1p and Est2p, were preferentially enriched at short telomeres in late S/G2 phase, the time of telomerase action. Tel1p, the yeast ATM-like checkpoint kinase, was highly enriched at short telomeres from early S through G2 phase and even into the next cell cycle. Nonetheless, induction of a single short telomere did not elicit a cell-cycle arrest. Tel1p binding was dependent on Xrs2p and required for preferential binding of telomerase to short telomeres. These data suggest that Tel1p targets telomerase to the DNA ends most in need of extension. PMID:17656141

  2. Hierarchical self-assembly of two-length-scale multiblock copolymers

    International Nuclear Information System (INIS)

    Brinke, Gerrit ten; Loos, Katja; Vukovic, Ivana; Du Sart, Gerrit Gobius

    2011-01-01

    The self-assembly in diblock copolymer-based supramolecules, obtained by hydrogen bonding short side chains to one of the blocks, as well as in two-length-scale linear terpolymers results in hierarchical structure formation. The orientation of the different domains, e.g. layers in the case of a lamellar-in-lamellar structure, is determined by the molecular architecture, graft-like versus linear, and the relative magnitude of the interactions involved. In both cases parallel and perpendicular arrangements have been observed. The comb-shaped supramolecules approach is ideally suited for the preparation of nanoporous structures. A bicontinuous morphology with the supramolecular comb block forming the channels was finally achieved by extending the original approach to suitable triblock copolymer-based supramolecules.

  3. Length-weight relationship of eleven species of marine catfishes from the northern Arabian Sea coast of Pakistan

    Science.gov (United States)

    Farooq, Noureen; Qamar, Nazia; Rashid, Shahnaz; Panhwar, Sher Khan

    2017-09-01

    This study records length-weight relationships (LWRs) for eleven commercially important marine catfish species of the family Ariidae (sea catfishes) and Plotosidae (eel catfishes) from the northern Arabian Sea coast of Pakistan. The specimens were sampled from December 2014 to November 2015, using bottom trawls with various mesh sizes by commercial vessels. The species were Nemapteryx caelatus, Sciades sona, Arius gagora, Batrachocephalus mino, Netuma thalassina, N. bilineata, Osteogeneiosus militaris, Plicofollis dussumieri, P. tenuispinis, Plotosus limbatus, and P. lineatus. Of the eleven species, two species A. gagora and N. bilineata were recorded for the first time and LWRs for four species A. gagora, N. bilineata, S. sona, and B. mino still have no data in the FishBase database. In addition, new maximum length for each of the three species N. bilineata, O. militaris and B. mino was also found.

  4. Short Implants: New Horizon in Implant Dentistry.

    Science.gov (United States)

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  5. Electronic health record use, intensity of hospital care, and patient outcomes.

    Science.gov (United States)

    Blecker, Saul; Goldfeld, Keith; Park, Naeun; Shine, Daniel; Austrian, Jonathan S; Braithwaite, R Scott; Radford, Martha J; Gourevitch, Marc N

    2014-03-01

    Previous studies have suggested that weekend hospital care is inferior to weekday care and that this difference may be related to diminished care intensity. The purpose of this study was to determine whether a metric for measuring intensity of hospital care based on use of the electronic health record was associated with patient-level outcomes. We performed a cohort study of hospitalizations at an academic medical center. Intensity of care was defined as the hourly number of provider accessions of the electronic health record, termed "electronic health record interactions." Hospitalizations were categorized on the basis of the mean difference in electronic health record interactions between the first Friday and the first Saturday of hospitalization. We used regression models to determine the association of these categories with patient outcomes after adjusting for covariates. Electronic health record interactions decreased from Friday to Saturday in 77% of the 9051 hospitalizations included in the study. Compared with hospitalizations with no change in Friday to Saturday electronic health record interactions, the relative lengths of stay for hospitalizations with a small, moderate, and large decrease in electronic health record interactions were 1.05 (95% confidence interval [CI], 1.00-1.10), 1.11 (95% CI, 1.05-1.17), and 1.25 (95% CI, 1.15-1.35), respectively. Although a large decrease in electronic health record interactions was associated with in-hospital mortality, these findings were not significant after risk adjustment (odds ratio 1.74, 95% CI, 0.93-3.25). Intensity of inpatient care, measured by electronic health record interactions, significantly diminished from Friday to Saturday, and this decrease was associated with length of stay. Hospitals should consider monitoring and correcting temporal fluctuations in care intensity. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Measurements of 3D slip velocities and plasma column lengths of a gliding arc discharge

    DEFF Research Database (Denmark)

    Zhu, Jiajian; Gao, Jinlong; Ehn, Andreas

    2015-01-01

    A non-thermal gliding arc discharge was generated at atmospheric pressure in an air flow. The dynamics of the plasma column and tracer particles were recorded using two synchronized high-speed cameras. Whereas the data analysis for such systems has previously been performed in 2D (analyzing......, gives more realistic insight into the convection cooling process. Additionally, with the determination of the 3D slip velocity and the 3D length of the plasma column, we give more accurate estimates for the drag force, the electric field strength, the power per unit length, and the radius...

  7. CSR Wake for a Short Magnet in Ultra-Relativistic Limit

    International Nuclear Information System (INIS)

    Emma, Paul J

    2002-01-01

    Using results for the CSR wake in a short magnet [1] we obtain expressions for the wake in the limit of very large values of the relativistic factor γ, γ → ∞, for both the entrance and exit of the magnet. The analytical results are illustrated with numerical computation of the wakes, energy loss and energy spread for magnets of different lengths

  8. International Mechanisms to Support Records, Knowledge and Memory Preservation Over the Short and Medium Term

    International Nuclear Information System (INIS)

    Schneider, Thierry; Andresz, Sylvain; Reaud, Cynthia; Dumont, Jean-Noel

    2015-07-01

    The aim of this analysis is to investigate the potential usefulness of mechanisms that have international influence, scope or support and are based on international cooperation, for the preservation of records, knowledge and memory (RK and M) about radioactive waste in the short and medium term. Eleven international mechanisms set up through the United Nations Educational, Scientific and Cultural Organization (UNESCO), the United Nations Economic Commission for Europe (UNECE), the International Atomic Energy Agency (IAEA) and the European Commission (EC) were analysed following two main objectives: identifying the key characteristics of the organisations coordinating the international mechanisms and analysing the contribution of those mechanisms to the preservation of records, memory and knowledge. This analysis points out that the link with international organisations provides international mechanisms with important technical and administrative support as well as with fora for dialogue. The voluntary involvement of contracting parties to join the individual mechanisms for a common goal and their declaration of adhesion to the objectives constitute the driving force of various international conventions. Nevertheless, the efficacy of these mechanisms can be limited in case of conflict. Most of these mechanisms are based on the recognition of individual and societal rights for protection issues, and entail that each contracting party assumes the mechanism's responsibilities. The mechanisms provide a platform for establishing an 'evolving' convention. The prime objective of the conventions examined in this document lies on economic development, while the international mechanisms associated with them also emphasise the necessity to take into account societal and environmental issues. The link with more general frameworks allows the mobilisation of regular funds. Beyond the funds, it is important to mention that the efficiency also relies on the capacity of the various

  9. Short-channel field-effect transistors with 9-atom and 13-atom wide graphene nanoribbons.

    Science.gov (United States)

    Llinas, Juan Pablo; Fairbrother, Andrew; Borin Barin, Gabriela; Shi, Wu; Lee, Kyunghoon; Wu, Shuang; Yong Choi, Byung; Braganza, Rohit; Lear, Jordan; Kau, Nicholas; Choi, Wonwoo; Chen, Chen; Pedramrazi, Zahra; Dumslaff, Tim; Narita, Akimitsu; Feng, Xinliang; Müllen, Klaus; Fischer, Felix; Zettl, Alex; Ruffieux, Pascal; Yablonovitch, Eli; Crommie, Michael; Fasel, Roman; Bokor, Jeffrey

    2017-09-21

    Bottom-up synthesized graphene nanoribbons and graphene nanoribbon heterostructures have promising electronic properties for high-performance field-effect transistors and ultra-low power devices such as tunneling field-effect transistors. However, the short length and wide band gap of these graphene nanoribbons have prevented the fabrication of devices with the desired performance and switching behavior. Here, by fabricating short channel (L ch  ~ 20 nm) devices with a thin, high-κ gate dielectric and a 9-atom wide (0.95 nm) armchair graphene nanoribbon as the channel material, we demonstrate field-effect transistors with high on-current (I on  > 1 μA at V d  = -1 V) and high I on /I off  ~ 10 5 at room temperature. We find that the performance of these devices is limited by tunneling through the Schottky barrier at the contacts and we observe an increase in the transparency of the barrier by increasing the gate field near the contacts. Our results thus demonstrate successful fabrication of high-performance short-channel field-effect transistors with bottom-up synthesized armchair graphene nanoribbons.Graphene nanoribbons show promise for high-performance field-effect transistors, however they often suffer from short lengths and wide band gaps. Here, the authors use a bottom-up synthesis approach to fabricate 9- and 13-atom wide ribbons, enabling short-channel transistors with 10 5 on-off current ratio.

  10. Induction of short culm mutants for bread wheat by using gamma rays

    International Nuclear Information System (INIS)

    Sobieh, S.S.

    2002-01-01

    This investigation was conducted at the experimental farm of plant research department, nuclear research center, atomic energy authority, Inshas in order to select some short culm mutants from the local wheat varieties; Sid's-5, Sid's-6 and Sid's-7 after gamma irradiation. The obtained results indicated that: 1-M 4 mutants progenies retained the features of their M 3 selections. 2-Some short culm mutants exhibited high grain yield/plant as compared to their original varieties. 3-There were significant decreases in plant height varied from 21.4 to 35.4%. This reduction was due to the shorting of culm inter nods length. As well as, the reduction diameter/culm especially diameter of the inter nods/culm did not differed between original varieties and the mutants. 4-The correlation between grain yield/plant and number of spikes/plant was positive and highly significant for most mutants and the original varieties as well. Data also showed that there were positive relationship between grain yield/plant and number of grains/spike and and length of the inter nods/culm. Positive or negative association between grain yield/plant and plant height as well as diameters of inter nods/culm for mutants and original varieties were detected

  11. 33 CFR 157.150 - Crude Oil Washing Operations and Equipment Manual: Recording information after inspections.

    Science.gov (United States)

    2010-07-01

    ... Equipment Manual: Recording information after inspections. 157.150 Section 157.150 Navigation and Navigable... Vessels Inspections § 157.150 Crude Oil Washing Operations and Equipment Manual: Recording information... machines. (2) Revolutions, number of cycles, and length of cycles of each COW machine. (3) Pressure and...

  12. High frequency study of a short niobium/lead alloy line

    International Nuclear Information System (INIS)

    Mazuer, J.; Gilchrist, J.

    1974-01-01

    The resonant Q-factors of coaxial lines 1.42 m in length, consisting of fine niobium wires in superconducting tubes, have been studied. The lines are either open-circuited at each end or else short-circuited at each end. In either case the fundamental resonance and odd harmonics up to the ninth were observed. Various surface treatments of the wire made no appreciable difference to the Q value of the open-circuited lines. The short-circuited lines had much lower Q values due to imperfect short-circuiting contacts, and were used mainly to study the effect of a superposed direct current. This was appreciable even when the current was much smaller than the current that the wire would support without resistive transition. The additional high-frequency loss caused by the current was attributed to flux penetration. (author)

  13. Effect of stereochemistry, chain length and sequence pattern on antimicrobial properties of short synthetic β-sheet forming peptide amphiphiles.

    Science.gov (United States)

    Ong, Zhan Yuin; Cheng, Junchi; Huang, Yuan; Xu, Kaijin; Ji, Zhongkang; Fan, Weimin; Yang, Yi Yan

    2014-01-01

    In the face of mounting global antibiotics resistance, the identification and development of membrane-active antimicrobial peptides (AMPs) as an alternative class of antimicrobial agent have gained significant attention. The physical perturbation and disruption of microbial membranes by the AMPs have been proposed to be an effective means to overcome conventional mechanisms of drug resistance. Recently, we have reported the design of a series of short synthetic β-sheet folding peptide amphiphiles comprised of recurring (X1Y1X2Y2)n-NH2 sequences where X: hydrophobic amino acids, Y: cationic amino acids and n: number of repeat units. In efforts to investigate the effects of key parameters including stereochemistry, chain length and sequence pattern on antimicrobial effects, systematic d-amino acid substitutions of the lead peptides (IRIK)2-NH2 (IK8-all L) and (IRVK)3-NH2 (IK12-all L) were performed. It was found that the corresponding D-enantiomers exhibited stronger antimicrobial activities with minimal or no change in hemolytic activities, hence translating very high selectivity indices of 407.0 and >9.8 for IK8-all D and IK12-all D respectively. IK8-all D was also demonstrated to be stable to degradation by broad spectrum proteases trypsin and proteinase K. The membrane disrupting bactericidal properties of IK8-all D effectively prevented drug resistance development and inhibited the growth of various clinically isolated MRSA, VRE, Acinetobacter baumanni, Pseudomonas aeruginosa, Cryptococcus. neoformans and Mycobacterium tuberculosis. Significant reduction in intracellular bacteria counts was also observed following treatment with IK8-all D in the Staphylococcus. aureus infected mouse macrophage cell line RAW264.7 (P < 0.01). These results suggest that the d-amino acids substituted β-sheet forming peptide IK8-all D with its enhanced antimicrobial activities and improved protease stability, is a promising therapeutic candidate with potential to combat

  14. Swedish National Seismic Network (SNSN). A short report on recorded earthquakes during the fourth quarter of the year 2010

    Energy Technology Data Exchange (ETDEWEB)

    Boedvarsson, Reynir (Uppsala Univ. (Sweden), Dept. of Earth Sciences)

    2011-01-15

    According to an agreement with Swedish Nuclear Fuel and Waste Management Company (SKB) and Uppsala Univ., the Dept. of Earth Sciences has continued to carry out observations of seismic events at seismic stations within the Swedish National Seismic Network (SNSN). This short report gives brief information about the recorded seismicity during October through December 2010. The Swedish National Seismic Network consists of 62 stations. During October through December, 2,241 events were located whereof 158 are estimated as real earthquakes, 1,457 are estimated as explosions, 444 are induced earthquakes in the vicinity of the mines in Kiruna and Malmberget and 182 events are still considered as uncertain but these are most likely explosions and are mainly located outside the network. One earthquake had a magnitude above M{sub L} = 2.0 during the period. In November one earthquake was located 13 km SW of Haernoesand with a magnitude of M{sub L} = 2.1. The largest earthquake in October had a magnitude of M{sub L} = 1.7 and was located 12 km NE of Eksjoe and in December an earthquake with a magnitude of M{sub L} = 1.8 was located 19 km north of Motala

  15. Spectral shifts of mammalian ultraviolet-sensitive pigments (short wavelength-sensitive opsin 1) are associated with eye length and photic niche evolution.

    Science.gov (United States)

    Emerling, Christopher A; Huynh, Hieu T; Nguyen, Minh A; Meredith, Robert W; Springer, Mark S

    2015-11-22

    Retinal opsin photopigments initiate mammalian vision when stimulated by light. Most mammals possess a short wavelength-sensitive opsin 1 (SWS1) pigment that is primarily sensitive to either ultraviolet or violet light, leading to variation in colour perception across species. Despite knowledge of both ultraviolet- and violet-sensitive SWS1 classes in mammals for 25 years, the adaptive significance of this variation has not been subjected to hypothesis testing, resulting in minimal understanding of the basis for mammalian SWS1 spectral tuning evolution. Here, we gathered data on SWS1 for 403 mammal species, including novel SWS1 sequences for 97 species. Ancestral sequence reconstructions suggest that the most recent common ancestor of Theria possessed an ultraviolet SWS1 pigment, and that violet-sensitive pigments evolved at least 12 times in mammalian history. We also observed that ultraviolet pigments, previously considered to be a rarity, are common in mammals. We then used phylogenetic comparative methods to test the hypotheses that the evolution of violet-sensitive SWS1 is associated with increased light exposure, extended longevity and longer eye length. We discovered that diurnal mammals and species with longer eyes are more likely to have violet-sensitive pigments and less likely to possess UV-sensitive pigments. We hypothesize that (i) as mammals evolved larger body sizes, they evolved longer eyes, which limited transmittance of ultraviolet light to the retina due to an increase in Rayleigh scattering, and (ii) as mammals began to invade diurnal temporal niches, they evolved lenses with low UV transmittance to reduce chromatic aberration and/or photo-oxidative damage. © 2015 The Author(s).

  16. Temperature-sensitive elastin-mimetic dendrimers: Effect of peptide length and dendrimer generation to temperature sensitivity.

    Science.gov (United States)

    Kojima, Chie; Irie, Kotaro; Tada, Tomoko; Tanaka, Naoki

    2014-06-01

    Dendrimers are synthetic macromolecules with unique structure, which are a potential scaffold for peptides. Elastin is one of the main components of extracellular matrix and a temperature-sensitive biomacromolecule. Previously, Val-Pro-Gly-Val-Gly peptides have been conjugated to a dendrimer for designing an elastin-mimetic dendrimer. In this study, various elastin-mimetic dendrimers using different length peptides and different dendrimer generations were synthesized to control the temperature dependency. The elastin-mimetic dendrimers formed β-turn structure by heating, which was similar to the elastin-like peptides. The elastin-mimetic dendrimers exhibited an inverse phase transition, largely depending on the peptide length and slightly depending on the dendrimer generation. The elastin-mimetic dendrimers formed aggregates after the phase transition. The endothermal peak was observed in elastin-mimetic dendrimers with long peptides, but not with short ones. The peptide length and the dendrimer generation are important factors to tune the temperature dependency on the elastin-mimetic dendrimer. Copyright © 2013 Wiley Periodicals, Inc.

  17. Length of Stay After Childbirth in 92 Countries and Associated Factors in 30 Low- and Middle-Income Countries: Compilation of Reported Data and a Cross-sectional Analysis from Nationally Representative Surveys.

    Directory of Open Access Journals (Sweden)

    Oona M R Campbell

    2016-03-01

    Full Text Available Following childbirth, women need to stay sufficiently long in health facilities to receive adequate care. Little is known about length of stay following childbirth in low- and middle-income countries or its determinants.We described length of stay after facility delivery in 92 countries. We then created a conceptual framework of the main drivers of length of stay, and explored factors associated with length of stay in 30 countries using multivariable linear regression. Finally, we used multivariable logistic regression to examine the factors associated with stays that were "too short" (<24 h for vaginal deliveries and <72 h for cesarean-section deliveries. Across countries, the mean length of stay ranged from 1.3 to 6.6 d: 0.5 to 6.2 d for singleton vaginal deliveries and 2.5 to 9.3 d for cesarean-section deliveries. The percentage of women staying too short ranged from 0.2% to 83% for vaginal deliveries and from 1% to 75% for cesarean-section deliveries. Our conceptual framework identified three broad categories of factors that influenced length of stay: need-related determinants that required an indicated extension of stay, and health-system and woman/family dimensions that were drivers of inappropriately short or long stays. The factors identified as independently important in our regression analyses included cesarean-section delivery, birthweight, multiple birth, and infant survival status. Older women and women whose infants were delivered by doctors had extended lengths of stay, as did poorer women. Reliance on factors captured in secondary data that were self-reported by women up to 5 y after a live birth was the main limitation.Length of stay after childbirth is very variable between countries. Substantial proportions of women stay too short to receive adequate postnatal care. We need to ensure that facilities have skilled birth attendants and effective elements of care, but also that women stay long enough to benefit from these. The

  18. Fishery of the short-necked clam Paphia undulata in Southern Negros Occidental, Central Philippines

    Directory of Open Access Journals (Sweden)

    Karen A. Villarta

    2010-06-01

    Full Text Available This study documents the fishery of the short-necked clam Paphia undulata in coastal waters of southern Negros Occidental. Catch and effort estimates were determined based on daily records of compressor divers gathered between February-July 2008 in Himamaylan City and July 2008-May 2009 in the town of Hinigaran. Fishing and marketing practices in both areas were also documented and population biology information noted.Compared to earlier conditions, present fishing patterns show a worsened stage of overexploitation primarily characterized by collection of predominantly small and immature (mostly <45 mm shell lengths sizes. Intensity/duration and location of fishing also varied due to both abundance and demand factors.The difference in sizes of clams and the varying fishing durations in each area suggest a non-uniform pattern of settlement resulting most likely from differential larval recruitment, the likely factors causing the local boom and bust fishery. The larger and long term extent of the effect of these factors can only be further investigated by parallel 2-3 year fishery-dependent and -independent surveys

  19. Leukocyte Telomere Length and Serum Levels of High-Molecular-Weight Adiponectin and Dehydroepiandrosterone-Sulfate Could Reflect Distinct Aspects of Longevity in Japanese Centenarians

    Directory of Open Access Journals (Sweden)

    Yuji Aoki MD, PhD

    2017-03-01

    Full Text Available Leukocyte telomere length and serum levels of high-molecular-weight adiponectin and dehydroepiandrosterone-sulfate (DHEA-S were assessed in association with nutrition and performance status (PS in Japanese centenarians. Twenty-three centenarians (five men, 18 women were classified according to their PS 1 (nearly fully ambulatory, n = 2, 2 (in bed less than 50% of daytime, n = 10, 3 (in bed greater than 50%, n = 6, and 4 (completely bedridden, n = 5. Leukocyte telomere length was determined by the hybridization protection assay, and the adiponectin and DHEA-S levels were measured by chemiluminescent enzyme immunoassay. Among variables of PS, body mass index (BMI, albumin, adiponectin, DHEA-S, and telomere length, there were significant correlations between PS and albumin ( r = −.694, p < .01, between telomere length and BMI ( r = .522, p < .05, between adiponectin and BMI ( r = −.574, p < .01, and between DHEA-S and albumin ( r = .530, p < .01. When excluding two cancer-bearing centenarians with short telomere, telomere length significantly correlated with PS ( r = −.632, p < .01. It was indicated that the short leukocyte telomere was associated with poor PS and cancer development and that the adiponectin or DHEA-S was associated with adiposity or nutritional status. Despite a small number of subjects, these biomarkers seemed to reflect distinct aspects of longevity in Japanese centenarians.

  20. Short distance modification of the quantum virial theorem

    Science.gov (United States)

    Zhao, Qin; Faizal, Mir; Zaz, Zaid

    2017-07-01

    In this letter, we will analyse the deformation of a semi-classical gravitational system from minimal measurable length scale. In the semi-classical approximation, the gravitational field will be analysed as a classical field, and the matter fields will be treated quantum mechanically. Thus, using this approximation, this system will be represented by a deformation of Schrödinger-Newton equation by the generalised uncertainty principle (GUP). We will analyse the effects of this GUP deformed Schrödinger-Newton equation on the behaviour of such a semi-classical gravitational system. As the quantum mechanical virial theorem can be obtained using the Schrödinger-Newton equation, a short distance modification of the Schrödinger-Newton equation will also result in a short distance modification of the quantum mechanical virial theorem.

  1. A Secure and Efficient Certificateless Short Signature Scheme

    Directory of Open Access Journals (Sweden)

    Lin Cheng

    2013-07-01

    Full Text Available Certificateless public key cryptography combines advantage of traditional public key cryptography and identity-based public key cryptography as it avoids usage of certificates and resolves the key escrow problem. In 2007, Huang et al. classified adversaries against certificateless signatures according to their attack power into normal, strong and super adversaries (ordered by their attack power. In this paper, we propose a new certificateless short signature scheme and prove that it is secure against both of the super type I and the super type II adversaries. Our new scheme not only achieves the strongest security level but also has the shortest signature length (one group element. Compared with the other short certificateless signature schemes which have a similar security level, our new scheme has less operation cost.

  2. Audit of long-term and short-term liabilities

    Directory of Open Access Journals (Sweden)

    Korinko M.D.

    2017-03-01

    Full Text Available The article determines the importance of long-term and short-term liabilities for the management of financial and material resources of an enterprise. It reviews the aim, objects and information generators for realization of audit of short-term and long-term obligations. The organizing and methodical providing of audit of long-term and short-term liabilities of an enterprise are generalized. The authors distinguish the stages of realization of audit of long-term and short-term liabilities, the aim of audit on each of the presented stages, and recommend methodical techniques. It is fixed that it is necessary to conduct the estimation of the systems of internal control and record-keeping of an enterprise by implementation of public accountant procedures for determination of volume and maintenance of selection realization. After estimating the indicated systems, a public accountant determines the methodology for realization of public accountant verification of long-term and short-term liabilities. The analytical procedures that public accountants are expedient to use for realization of audit of short-term and long-term obligations are determined. The authors suggest the classification of the educed defects on the results of the conducted public accountant verification of short-term and long-term obligations.

  3. Short linear shadows connecting pulmonary segmental arteries to oblique fissures in volumetric thin-section CT images: comparing CT, micro-CT and histopathology

    International Nuclear Information System (INIS)

    Guan, Chun-Shuang; Ma, Da-Qing; Chen, Jiang-Hong; Chen, Bu-Dong; Cui, Dun; Zhang, Yan-Song; Liu, Wei-Hua

    2016-01-01

    To retrospectively evaluate short linear shadows connecting pulmonary segmental arteries to oblique fissures in thin-section CT images and determine their anatomical basis. CT scanning was performed on 108 patients and 11 lung specimens with no lung diseases around the oblique fissures or hilar. Two radiologists evaluated the imaging. The parameters included length, thickness of short linear shadows, pulmonary segmental artery variations, and traction interlobar fissures, etc. The short linear shadows were not related to sex, age, or smoking history. The lengths of the short linear shadows were generally within 10 mm. The thicknesses of the short linear shadows ranged from 1 to 2 mm. Of the patients, 26.9 % showed pulmonary segmental artery variations; 66.7 % of short linear shadows pulled oblique fissures. In three-dimensional images, the short linear shadows appeared as arc planes, with one side edge connected to the oblique fissure, one side edge connected to a pulmonary segmental artery. On the tissue slices, the short linear shadow exhibited a band structure composed of connective tissues, small blood vessels, and small lymphatic vessels. Short linear shadows are a type of normal intrapulmonary membranes and can maintain the integrity of the oblique fissures and hilar structure. (orig.)

  4. The effect of length, duration, and intensity of psychological therapy on CORE global distress scores.

    Science.gov (United States)

    Evans, Lauren Jayne; Beck, Alison; Burdett, Mark

    2017-09-01

    This study explores whether improvements, as measured by the CORE-OM/10, as a result of psychological therapy were related to length of treatment in weeks, number of treatment sessions, or treatment intensity, as well as any effect of diagnostic group. Pre- and post-therapy CORE-OM/10 scores were extracted from the clinical records of all secondary care adult psychological therapy team patients who undertook psychological therapy between 2010 and 2013 in one mental health trust. Of the 4,877 patients identified, 925 had complete records. Length of therapy was divided by the number of sessions to create 'treatment intensity' (sessions per week). Nonparametric analyses were used, initial score was controlled for, and diagnostic group was explored. No relationship was found between change in score and the number of sessions, therapy length, or treatment intensity; however, change in score was positively correlated with first-session score. Patients with higher initial scores had longer therapies; however, treatment intensity was similar for patients with lower pre-therapy distress. There were differences in treatment length (weeks) between diagnostic groups. Demographic differences were found between patients with and without complete records, prompting caution in terms of generalizability. These findings are consistent with the responsive regulation model (Barkham et al., 1996) which proposes that patients vary in their response to treatment, resulting in no associations between session numbers or treatment intensity and therapeutic gain with aggregated scores. Patients with higher CORE scores at the outset of psychological therapy had longer not more intensive therapy. There was variation in treatment intensity between diagnostic clusters. Number of sessions, length of therapy (in weeks), and treatment intensity (the number of sessions per week between the first and last therapy sessions) were not related to therapeutic gains. These results fit with a responsive

  5. Gridded sunshine duration climate data record for Germany based on combined satellite and in situ observations

    Science.gov (United States)

    Walawender, Jakub; Kothe, Steffen; Trentmann, Jörg; Pfeifroth, Uwe; Cremer, Roswitha

    2017-04-01

    The purpose of this study is to create a 1 km2 gridded daily sunshine duration data record for Germany covering the period from 1983 to 2015 (33 years) based on satellite estimates of direct normalised surface solar radiation and in situ sunshine duration observations using a geostatistical approach. The CM SAF SARAH direct normalized irradiance (DNI) satellite climate data record and in situ observations of sunshine duration from 121 weather stations operated by DWD are used as input datasets. The selected period of 33 years is associated with the availability of satellite data. The number of ground stations is limited to 121 as there are only time series with less than 10% of missing observations over the selected period included to keep the long-term consistency of the output sunshine duration data record. In the first step, DNI data record is used to derive sunshine hours by applying WMO threshold of 120 W/m2 (SDU = DNI ≥ 120 W/m2) and weighting of sunny slots to correct the sunshine length between two instantaneous image data due to cloud movement. In the second step, linear regression between SDU and in situ sunshine duration is calculated to adjust the satellite product to the ground observations and the output regression coefficients are applied to create a regression grid. In the last step regression residuals are interpolated with ordinary kriging and added to the regression grid. A comprehensive accuracy assessment of the gridded sunshine duration data record is performed by calculating prediction errors (cross-validation routine). "R" is used for data processing. A short analysis of the spatial distribution and temporal variability of sunshine duration over Germany based on the created dataset will be presented. The gridded sunshine duration data are useful for applications in various climate-related studies, agriculture and solar energy potential calculations.

  6. Condition-dependent female preference for male genitalia length is based on male reproductive tactics.

    Science.gov (United States)

    Hernandez-Jimenez, Armando; Rios-Cardenas, Oscar

    2017-12-06

    There is extensive morphological variation of male genitalia across animals with internal fertilization, even among closely related species. Most studies attempting to explain this extraordinary diversity have focused on processes that occur post-copula (e.g. sperm competition, cryptic female choice). Only a few studies have focused on the pre-copula process of female preference. In addition, the extent to which this variation could be associated with the use of different reproductive tactics has yet to be explored. Here, we show that female preference for male genitalia length in two livebearing fishes depends on the type of reproductive tactic of the males being evaluated as well as the body condition of the female. In a species where all males coax females to acquire matings (courters), females preferred males with short genitalia. In a species with genetically influenced alternative reproductive tactics (courter males that only court and produce courter sons, sneaker males that use the coercive tactic of sneak chase and produce sneaker sons), female preference depended on an interaction between male tactic and female condition: females in good condition preferred courter males with short genitalia, and sneaker males with long genitalia. Our results suggest that female preference for male traits favourable to their sons may be an important factor contributing to the diversification of male genitalia. Despite the contrasting selection for genitalia length that our female preference tests suggest, we found no significant differences in genitalia length between coaxing (courters) and coercive (sneakers) males. Our study represents a starting point to more clearly understand the role of alternative reproductive tactics and variation in female mate preference in the evolution of male genitalia. © 2017 The Author(s).

  7. Influence of slab length on dynamic characteristics of subway train-steel spring floating slab track-tunnel coupled system

    Directory of Open Access Journals (Sweden)

    Qing-yuan Xu

    Full Text Available A subway train-steel spring floating slab track-tunnel coupling dynamic model, considering short and middle-long wavelength random track irregularities, and longitudinal connection between adjacent slabs of steel spring floating slab track, was developed. And the influence of slab length on dynamic characteristics of the system under different track conditions and train speeds are theoretically studied. The calculated results show: (1 In general, the acceleration of each component of the coupled system decreases with the increase of slab length under the perfectly smooth track condition; (2 Slab length has different influence laws on acceleration of each component of subway train-steel spring floating slab track-tunnel coupled system under random irregularity of track condition. The lower the dominant frequency distribution of vibration acceleration is, the higher influence slab length has; (3 With the increase of slab length, the force of rail, fastener and steel spring also decreases significantly, which helps to lengthen the service life of these components; (4 With the increase of slab length, the longitudinal bending moment of slab increases sharply at first, then it begins to drop slightly. When slab length exceeds the distance between two bogies of a vehicle, the longitudinal bending moment of slab changes little; (5 Slab length has significant influence on the dynamic force and displacement of the coupled system when train speed is higher.

  8. Conflation of Short Identity-by-Descent Segments Bias Their Inferred Length Distribution

    Directory of Open Access Journals (Sweden)

    Charleston W. K. Chiang

    2016-05-01

    Full Text Available Identity-by-descent (IBD is a fundamental concept in genetics with many applications. In a common definition, two haplotypes are said to share an IBD segment if that segment is inherited from a recent shared common ancestor without intervening recombination. Segments several cM long can be efficiently detected by a number of algorithms using high-density SNP array data from a population sample, and there are currently efforts to detect shorter segments from sequencing. Here, we study a problem of identifiability: because existing approaches detect IBD based on contiguous segments of identity-by-state, inferred long segments of IBD may arise from the conflation of smaller, nearby IBD segments. We quantified this effect using coalescent simulations, finding that significant proportions of inferred segments 1–2 cM long are results of conflations of two or more shorter segments, each at least 0.2 cM or longer, under demographic scenarios typical for modern humans for all programs tested. The impact of such conflation is much smaller for longer (> 2 cM segments. This biases the inferred IBD segment length distribution, and so can affect downstream inferences that depend on the assumption that each segment of IBD derives from a single common ancestor. As an example, we present and analyze an estimator of the de novo mutation rate using IBD segments, and demonstrate that unmodeled conflation leads to underestimates of the ages of the common ancestors on these segments, and hence a significant overestimate of the mutation rate. Understanding the conflation effect in detail will make its correction in future methods more tractable.

  9. Relative blood loss and operative time can predict length of stay following orthognathic surgery.

    Science.gov (United States)

    Andersen, K; Thastum, M; Nørholt, S E; Blomlöf, J

    2016-10-01

    The aim of this study was to investigate the length of stay (LOS) following orthognathic surgery and thereby to establish a benchmark. The secondary aim was to identify predictors of postoperative LOS following orthognathic surgery. Patients were treated consecutively during the period 2010 to 2012. Inclusion criteria were (1) patient age ≥18 years, and (2) surgery involving a three-piece Le Fort I osteotomy, or a bilateral sagittal split osteotomy (BSSO), or bimaxillary surgery. A total of 335 patients were included. The following data were recorded: height, weight, body mass index (BMI), age, sex, operative time, intraoperative blood loss, and type of surgery. LOS was defined as the duration of time from date of surgery to date of discharge. The average LOS was 1.3 days following Le Fort I osteotomy, 1.3 days following BSSO, and 1.8 days following bimaxillary surgery. In the multivariate regression model (R(2)=0.11), predictors of a prolonged LOS were operative time (P<0.001) and relative blood loss (P=0.002). No significant effect of age, BMI, sex, or treatment on LOS was observed. The short duration of LOS found in this study supports the possibility of increasing outpatient pathways for selected patients. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. Fiber length and pulping characteristics of switchgrass, alfalfa stems, hybrid poplar and willow biomasses.

    Science.gov (United States)

    Ai, Jun; Tschirner, Ulrike

    2010-01-01

    Switchgrass (Panicum virgatum), alfalfa stems (Medicago sativa), second year growth hybrid poplar (Populus) and willow (Salix spp.) were examined to determine fiber characteristics, pulping behavior and paper properties. Alfalfa stems and switchgrass both showed length weighted average fiber length (LWW) of 0.78 mm, a very narrow fiber length distribution and high fines content. Willow and hybrid poplar have lower fines content but a very low average fiber length (0.42 and 0.48 mm LWW). In addition, the four biomass species showed distinctly different chemical compositions. Switchgrass was defibered successfully using Soda and Soda Anthraquinone (AQ) pulping and demonstrated good paper properties. Both fast-growing wood species pulped well using the Kraft process, and showed acceptable tensile strength, but low tear strength. Alfalfa stems reacted very poorly to Soda and Soda AQ pulping but responded well to Kraft and Kraft AQ. Pulps with tensile and tear strength considerably higher than those found for commercial aspen pulps were observed for alfalfa. All four biomass species examined demonstrated low pulp yield. The highest yields were obtained with poplar and switchgrass (around 43%). Considering the short fibers and low yields, all four biomass types will likely only be used in paper manufacturing if they offer considerable economic advantage over traditional pulp wood.

  11. Compressing and focusing a short laser pulse by a thin plasma lens

    International Nuclear Information System (INIS)

    Ren, C.; Duda, B. J.; Hemker, R. G.; Mori, W. B.; Katsouleas, T.; Antonsen, T. M.; Mora, P.

    2001-01-01

    We consider the possibility of using a thin plasma slab as an optical element to both focus and compress an intense laser pulse. By thin we mean that the focal length is larger than the lens thickness. We derive analytic formulas for the spot size and pulse length evolution of a short laser pulse propagating through a thin uniform plasma lens. The formulas are compared to simulation results from two types of particle-in-cell code. The simulations give a greater final spot size and a shorter focal length than the analytic formulas. The difference arises from spherical aberrations in the lens which lead to the generation of higher-order vacuum Gaussian modes. The simulations also show that Raman side scattering can develop. A thin lens experiment could provide unequivocal evidence of relativistic self-focusing

  12. Schroedinger operators with point interactions and short range expansions

    International Nuclear Information System (INIS)

    Albeverio, S.; Hoeegh-Krohn, R.; Oslo Univ.

    1984-01-01

    We give a survey of recent results concerning Schroedinger operators with point interactions in R 3 . In the case where the point interactions are located at a discrete set of points we discuss results about the resolvent, the spectrum, the resonances and the scattering quantities. We also discuss the approximation of point interactions by short range local potentials (short range or low energy expansions) and the one electron model of a 3-dimensional crystal. Moreover we discuss Schroedinger operators with Coulomb plus point interactions, with applications to the determination of scattering lengths and of level shifts in mesic atoms. Further applications to the multiple well problem, to multiparticle systems, to crystals with random impurities, to polymers and quantum fields are also briefly discussed. (orig.)

  13. A Comparison of the Psychometric Properties of the Psychopathic Personality Inventory Full-Length and Short-Form Versions

    Science.gov (United States)

    Kastner, Rebecca M.; Sellbom, Martin; Lilienfeld, Scott O.

    2012-01-01

    The Psychopathic Personality Inventory (PPI) has shown promising construct validity as a measure of psychopathy. Because of its relative efficiency, a short-form version of the PPI (PPI-SF) was developed and has proven useful in many psychopathy studies. The validity of the PPI-SF, however, has not been thoroughly examined, and no studies have…

  14. Shorter dialysis session length was not associated with lower mental health and physical functioning in elderly hemodialysis patients: Results from the Japan Dialysis Outcome and Practice Patterns Study (J-DOPPS.

    Directory of Open Access Journals (Sweden)

    Masashi Kitagawa

    Full Text Available Health-related quality of life (HRQOL is often prioritized over long-term survival in elderly patients. Although a longer dialysis session length (DSL has been shown to reduce mortality, its effects on improving the HRQOL are unknown.Using data from the Japan Dialysis Outcomes and Practice Patterns Study (J-DOPPS, patients aged ≥ 65 years on maintenance hemodialysis were enrolled. DSL was categorized as short (240 minutes. The primary outcomes were changes in mental health (ΔMH and physical functioning (ΔPF scores assessed using the Japanese version of SF-12, in one year. The differences in the ΔMH and ΔPF among the three groups were assessed via regression (beta coefficients derived using a linear regression model.Of 1,187 patients at baseline, 319 (26.9% had a short length, 686 (57.8% a medium length, and 182 (15.3% a long length. We assessed the ΔMH data from 793 patients and the ΔPF data from 738. No significant differences in the ΔMH were noted for the short or long groups compared with the medium group (score difference: 0.26, 95% confidence interval [CI]: -4.17 to 4.69 for short; score difference: -1.15, 95% CI: -6.17 to 3.86 for long. Similarly, no significant differences were noted for these groups versus the medium group in ΔPF either (score difference: -1.43, 95% CI: -6.73 to 3.87 for short; score difference: -1.71, 95% CI: -7.63 to 4.22 for long.A shorter DSL might have no adverse effects on MH or PF for elderly patients.

  15. Machine learning techniques for the optimization of joint replacements: Application to a short-stem hip implant.

    Science.gov (United States)

    Cilla, Myriam; Borgiani, Edoardo; Martínez, Javier; Duda, Georg N; Checa, Sara

    2017-01-01

    Today, different implant designs exist in the market; however, there is not a clear understanding of which are the best implant design parameters to achieve mechanical optimal conditions. Therefore, the aim of this project was to investigate if the geometry of a commercial short stem hip prosthesis can be further optimized to reduce stress shielding effects and achieve better short-stemmed implant performance. To reach this aim, the potential of machine learning techniques combined with parametric Finite Element analysis was used. The selected implant geometrical parameters were: total stem length (L), thickness in the lateral (R1) and medial (R2) and the distance between the implant neck and the central stem surface (D). The results show that the total stem length was not the only parameter playing a role in stress shielding. An optimized implant should aim for a decreased stem length and a reduced length of the surface in contact with the bone. The two radiuses that characterize the stem width at the distal cross-section in contact with the bone were less influential in the reduction of stress shielding compared with the other two parameters; but they also play a role where thinner stems present better results.

  16. Construction techniques for short iron-free dipole magnets

    International Nuclear Information System (INIS)

    Harvey, A.R.

    1983-01-01

    A method was developed for economically fabricating short, wire-wound, steering magnets with maximum length, cosine-distributed, axial elements. This method utilizes multifunctional tooling to precisely flat-wind two-layer dipole halves that are subsequently reformed and encapsulated into semicylindrical form with confinement of the end turns into thin, half discs normal to the magnet axis. This paper addresses the magnet fabrication in detail, highlighting the inherent quality control features of the tooling, overall construction costs, and contemplated manufacturing enhancements

  17. Short QTc Interval in Males with Klinefelter Syndrome-Influence of CAG Repeat Length, Body Composition, and Testosterone Replacement Therapy

    DEFF Research Database (Denmark)

    Jørgensen, Inger Norlyk; Skakkebaek, Anne; Andersen, Niels Holmark

    2015-01-01

    BackgroundKlinefelter syndrome (KS) is a sex chromosomal aneuploidy (47,XXY) affecting 1/660 males. Based on findings in Turner syndrome, we hypothesized that electrocardiogram (ECG) abnormalities would be present in males with KS. ObjectiveTo investigate ECGs in males with KS and compare...... syndrome was determined in participants with a QTc ... interval comparable to controls. No mutations in genes related to short QT syndrome were found. ConclusionWe found short QTc interval in males with KS, with further shortening of the QTc interval by T. These results suggest that genes on the X chromosome could be involved in regulation of the QTc interval...

  18. Generation of Length Distribution, Length Diagram, Fibrogram, and Statistical Characteristics by Weight of Cotton Blends

    Directory of Open Access Journals (Sweden)

    B. Azzouz

    2007-01-01

    Full Text Available The textile fibre mixture as a multicomponent blend of variable fibres imposes regarding the proper method to predict the characteristics of the final blend. The length diagram and the fibrogram of cotton are generated. Then the length distribution, the length diagram, and the fibrogram of a blend of different categories of cotton are determined. The length distributions by weight of five different categories of cotton (Egyptian, USA (Pima, Brazilian, USA (Upland, and Uzbekistani are measured by AFIS. From these distributions, the length distribution, the length diagram, and the fibrogram by weight of four binary blends are expressed. The length parameters of these cotton blends are calculated and their variations are plotted against the mass fraction x of one component in the blend .These calculated parameters are compared to those of real blends. Finally, the selection of the optimal blends using the linear programming method, based on the hypothesis that the cotton blend parameters vary linearly in function of the components rations, is proved insufficient.

  19. Kinematic Investigation of Lingual Movement in Words of Increasing Length in Acquired Apraxia of Speech

    Science.gov (United States)

    Bartle-Meyer, Carly J.; Goozee, Justine V.; Murdoch, Bruce E.

    2009-01-01

    The current study aimed to use electromagnetic articulography (EMA) to investigate the effect of increasing word length on lingual kinematics in acquired apraxia of speech (AOS). Tongue-tip and tongue-back movement was recorded for five speakers with AOS and a concomitant aphasia (mean age = 53.6 years; SD = 12.60) during target consonant…

  20. Developing Short Films of Geoscience Research

    Science.gov (United States)

    Shipman, J. S.; Webley, P. W.; Dehn, J.; Harrild, M.; Kienenberger, D.; Salganek, M.

    2015-12-01

    In today's prevalence of social media and networking, video products are becoming increasingly more useful to communicate research quickly and effectively to a diverse audience, including outreach activities as well as within the research community and to funding agencies. Due to the observational nature of geoscience, researchers often take photos and video footage to document fieldwork or to record laboratory experiments. Here we present how researchers can become more effective storytellers by collaborating with filmmakers to produce short documentary films of their research. We will focus on the use of traditional high-definition (HD) camcorders and HD DSLR cameras to record the scientific story while our research topic focuses on the use of remote sensing techniques, specifically thermal infrared imaging that is often used to analyze time varying natural processes such as volcanic hazards. By capturing the story in the thermal infrared wavelength range, in addition to traditional red-green-blue (RGB) color space, the audience is able to experience the world differently. We will develop a short film specifically designed using thermal infrared cameras that illustrates how visual storytellers can use these new tools to capture unique and important aspects of their research, convey their passion for earth systems science, as well as engage and captive the viewer.

  1. Universality in few-body systems with large scattering length

    International Nuclear Information System (INIS)

    Hammer, H.-W.

    2005-01-01

    Effective Field Theory (EFT) provides a powerful framework that exploits a separation of scales in physical systems to perform systematically improvable, model-independent calculations. Particularly interesting are few-body systems with short-range interactions and large two-body scattering length. Such systems display remarkable universal features. In systems with more than two particles, a three-body force with limit cycle behavior is required for consistent renormalization already at leading order. We will review this EFT and some of its applications in the physics of cold atoms and nuclear physics. In particular, we will discuss the possibility of an infrared limit cycle in QCD. Recent extensions of the EFT approach to the four-body system and N-boson droplets in two spatial dimensions will also be addressed

  2. Research Article Special Issue

    African Journals Online (AJOL)

    2017-10-05

    Oct 5, 2017 ... children's short stories were recorded by 3 female speakers and 2 ..... 8 GB memory card which is adequate fo laptop is used to ..... A long frame would result in very ... As the frame length increases, short-time energy becomes ...

  3. An Innovative Technique to Assess Spontaneous Baroreflex Sensitivity with Short Data Segments: Multiple Trigonometric Regressive Spectral Analysis.

    Science.gov (United States)

    Li, Kai; Rüdiger, Heinz; Haase, Rocco; Ziemssen, Tjalf

    2018-01-01

    Objective: As the multiple trigonometric regressive spectral (MTRS) analysis is extraordinary in its ability to analyze short local data segments down to 12 s, we wanted to evaluate the impact of the data segment settings by applying the technique of MTRS analysis for baroreflex sensitivity (BRS) estimation using a standardized data pool. Methods: Spectral and baroreflex analyses were performed on the EuroBaVar dataset (42 recordings, including lying and standing positions). For this analysis, the technique of MTRS was used. We used different global and local data segment lengths, and chose the global data segments from different positions. Three global data segments of 1 and 2 min and three local data segments of 12, 20, and 30 s were used in MTRS analysis for BRS. Results: All the BRS-values calculated on the three global data segments were highly correlated, both in the supine and standing positions; the different global data segments provided similar BRS estimations. When using different local data segments, all the BRS-values were also highly correlated. However, in the supine position, using short local data segments of 12 s overestimated BRS compared with those using 20 and 30 s. In the standing position, the BRS estimations using different local data segments were comparable. There was no proportional bias for the comparisons between different BRS estimations. Conclusion: We demonstrate that BRS estimation by the MTRS technique is stable when using different global data segments, and MTRS is extraordinary in its ability to evaluate BRS in even short local data segments (20 and 30 s). Because of the non-stationary character of most biosignals, the MTRS technique would be preferable for BRS analysis especially in conditions when only short stationary data segments are available or when dynamic changes of BRS should be monitored.

  4. Gap length distributions by PEPR

    International Nuclear Information System (INIS)

    Warszawer, T.N.

    1980-01-01

    Conditions guaranteeing exponential gap length distributions are formulated and discussed. Exponential gap length distributions of bubble chamber tracks first obtained on a CRT device are presented. Distributions of resulting average gap lengths and their velocity dependence are discussed. (orig.)

  5. Short communications Goose barnacles on seals and a penguin at ...

    African Journals Online (AJOL)

    Short communications Goose barnacles on seals and a penguin at Gough Island. ... to the pelage of two of the 12 elephant seals (Mirounga leonina) inspected and one ... We also recorded a goose barnacle attached to a Northern rockhopper ...

  6. Short dental implants versus standard dental implants placed in the posterior jaws: A systematic review and meta-analysis.

    Science.gov (United States)

    Lemos, Cleidiel Aparecido Araujo; Ferro-Alves, Marcio Luiz; Okamoto, Roberta; Mendonça, Marcos Rogério; Pellizzer, Eduardo Piza

    2016-04-01

    The purpose of the present systematic review and meta-analysis was to compare short implants (equal or less than 8mm) versus standard implants (larger than 8mm) placed in posterior regions of maxilla and mandible, evaluating survival rates of implants, marginal bone loss, complications and prosthesis failures. This review has been registered at PROSPERO under the number CRD42015016588. Main search terms were used in combination: dental implant, short implant, short dental implants, short dental implants posterior, short dental implants maxilla, and short dental implants mandible. An electronic search for data published up until September/2015 was undertaken using the PubMed/Medline, Embase and The Cochrane Library databases. Eligibility criteria included clinical human studies, randomized controlled trials and/or prospective studies, which evaluated short implants in comparison to standard implants in the same study. The search identified 1460 references, after inclusion criteria 13 studies were assessed for eligibility. A total of 1269 patients, who had received a total of 2631 dental implants. The results showed that there was no significant difference of implants survival (P=.24; RR:1.35; CI: 0.82-2.22), marginal bone loss (P=.06; MD: -0.20; CI: -0.41 to 0.00), complications (P=.08; RR:0.54; CI: 0.27-1.09) and prosthesis failures (P=.92; RR:0.96; CI: 0.44-2.09). Short implants are considered a predictable treatment for posterior jaws. However, short implants with length less than 8 mm (4-7 mm) should be used with caution because they present greater risks to failures compared to standard implants. Short implants are frequently placed in the posterior area in order to avoid complementary surgical procedures. However, clinicians need to be aware that short implants with length less than 8mm present greater risk of failures. Copyright © 2016. Published by Elsevier Ltd.

  7. Mammography: Correlation of pectoral muscle width and the length in the mediolateral oblique view of the breast

    International Nuclear Information System (INIS)

    Spuur, K.; Poulos, A.; Currie, G.; Rickard, M.

    2010-01-01

    Purpose: To investigate the relationship between the width and length of the pectoral muscle in the mediolateral oblique mammogram of the breast. Method: Mammograms reviewed for this study were performed on women undergoing routine mammographic screening with BreastScreen NSW South West, Australia. The study included a total of 2800 randomly selected mediolateral oblique mammograms from examinations taken between July 2004 and September 2006. Measurements of the width and length of the pectoral muscle were recorded. Results: No statistically significant difference was demonstrated between the mean values for right and left width (p = 0.5293) or length (p = 0.2079). Matched pair analysis demonstrated a statistically significant difference width, (p = 0.0069) and length, (p = 0.0369). No relationship could be demonstrated between the width and length of the pectoral muscle, (p = 0.0701). Conclusion: The inability to determine a relationship between the width and length of the pectoral muscle suggests that these criteria should be assessed independently of each other. This new understanding of the presentation of the pectoral muscle will enable clinically relevant redevelopment of current image evaluation systems to include statistically supported mean performance values. Further research is needed to explore the relationship of width and length to other key image evaluation criteria used in mammography image quality evaluation.

  8. Commissioning of an electro-optic electron bunch length monitor at FLASH

    International Nuclear Information System (INIS)

    Breunlin, Jonas

    2011-03-01

    The demands on the electron beam qualities for free-electron lasers (FEL) are challenging in terms of high peak currents. At FLASH, the high-gain FEL in Hamburg, longitudinal bunch compression is performed to achieve the requested high charge densities in short bunches. The precise control of the bunch compression process requires advanced diagnostics on the longitudinal bunch profile. The bunch length monitor presented in this thesis is based on a non-destructive detection using the electro-optic effect. The focus is on a compact and reliable system for permanent bunch diagnostics. The monitor provides single-shot measurements of the longitudinal bunch profiles with lengths of a few picoseconds by spectrally encoding their charge distribution. First measurements for characterization purpose have been performed. It has been shown that the monitor is suitable for monitoring the longitudinal bunch profile behind the first bunch compressor at FLASH. Electron bunch profiles with slopes corresponding to a full width half maximum of about 1.4 ps have been detected. That is the intrinsic resolution limit of the utilized method. (orig.)

  9. A device for automatically recording information on the reasons for idling of stopes

    Energy Technology Data Exchange (ETDEWEB)

    Dergachev, L G; Kuzoyatov, G I; Tereshchenko, V N

    1979-01-01

    One substantial reserve for raising production efficiency in the coal industry is reduction of nonproductive time costs. The state of the art of stoping work and design features of stoping equipment and devices for obtaining information do not presently enable complete automation of the process of obtaining data on the reasons for down times. Therefore, together with automatic data formation manual recording of information is required through remote control equipment to the controlling computer directly from the work place. The Donetsk department of the Giprougleavtomatizatsiy institute has developed the UKIP-1 device for automatic recording of information on the reasons for stope down times. The device is designed for use in an automatic process control system of coal mines. It provides coding of information and its conversion to a form suitable for transmission through remote control channels, further processing, and recording. The device enables recording of information on down times of eight objects of the stope. Up to eight down time reasons can be recorded for each object. The device has 2 contact outputs, on one of which is formed an informational sequential eight-bit code; on the other, 8 clock pulses. The device's code is generated automatically, after it is activated by a switch. The length of the code packet results from the maximum possible information transmission rate of the existing mine remote control systems, and equals 12+2 sec. The clock pulse length equals half the length of the information pulse. The device has been tested at coal mines, and recommended for industrial production. UKIP-1 devices are being used in a pilot model of an automatic production control system of the Sotsialisticheskiy Donbass Newspaper mine of the Donetskugol' production association.

  10. Consideration of reinforcement mechanism in the short fiber mixing granular materials by granular element simulations

    Science.gov (United States)

    Mori, Kentaro; Kaneko, Kenji; Hashizume, Yutaka

    2017-06-01

    The short fiber mixing method is well known as one of the method to improve the strength of gran- ular soils in geotechnical engineering. Mechanical properties of the short fiber mixing granular materials are influenced by many factors, such as the mixture ratio of the short fiber, the material of short fiber, the length, and the orientation. In particular, the mixture ratio of the short fibers is very important in mixture design. In the past study, we understood that the strength is reduced by too much short fiber mixing by a series of tri-axial compression experiments. Namely, there is "optimum mixture ratio" in the short fiber mixing granular soils. In this study, to consider the mechanism of occurrence of the optimum mixture ratio, we carried out the numerical experiments by granular element method. As the results, we can understand that the strength decrease when too much grain-fiber contact points exist, because a friction coefficient is smaller than the grain-grain contact points.

  11. Development of a scanning tunneling potentiometry system for measurement of electronic transport at short length scales

    Science.gov (United States)

    Rozler, Michael

    It is clear that complete understanding of macroscopic properties of materials is impossible without a thorough knowledge of behavior at the smallest length scales. While the past 25 years have witnessed major advances in a variety of techniques that probe the nanoscale properties of matter, electrical transport measurements -- the heart of condensed matter research -- have lagged behind, never progressing beyond bulk measurements. This thesis describes a scanning tunneling potentiometry (STP) system developed to simultaneously map the transport-related electrochemical potential distribution of a biased sample along with its surface topography, extending electronic transport measurements to the nanoscale. Combining a novel sample biasing technique with a continuous current-nulling feedback scheme pushes the noise performance of the measurement to its fundamental limit - the Johnson noise of the STM tunnel junction. The resulting 130 nV voltage sensitivity allows us to spatially resolve local potentials at scales down to 2 nm, while maintaining atomic scale STM imaging, all at scan sizes of up to 15 microns. A mm-range two-dimensional coarse positioning stage and the ability to operate from liquid helium to room temperature with a fast turn-around time greatly expand the versatility of the instrument. Use of carefully selected model materials, combined with excellent topographic and voltage resolution has allowed us to distinguish measurement artifacts caused by surface roughness from true potentiometric features, a major problem in previous STP measurements. The measurements demonstrate that STP can produce physically meaningful results for homogeneous transport as well as non-uniform conduction dominated by material microstructures. Measurements of several physically interesting materials systems are presented as well, revealing new behaviors at the smallest length sales. The results establish scanning tunneling potentiometry as a useful tool for physics and

  12. Ultra-short silicon MMI duplexer

    Science.gov (United States)

    Yi, Huaxiang; Huang, Yawen; Wang, Xingjun; Zhou, Zhiping

    2012-11-01

    The fiber-to-the-home (FTTH) systems are growing fast these days, where two different wavelengths are used for upstream and downstream traffic, typically 1310nm and 1490nm. The duplexers are the key elements to separate these wavelengths into different path in central offices (CO) and optical network unit (ONU) in passive optical network (PON). Multimode interference (MMI) has some benefits to be a duplexer including large fabrication tolerance, low-temperature dependence, and low-polarization dependence, but its size is too large to integrate in conventional case. Based on the silicon photonics platform, ultra-short silicon MMI duplexer was demonstrated to separate the 1310nm and 1490nm lights. By studying the theory of self-image phenomena in MMI, the first order images are adopted in order to keep the device short. A cascaded MMI structure was investigated to implement the wavelength splitting, where both the light of 1310nm and 1490nm was input from the same port, and the 1490nm light was coupling cross the first MMI and output at the cross-port in the device while the 1310nm light was coupling through the first and second MMI and output at the bar-port in the device. The experiment was carried on with the SOI wafer of 340nm top silicon. The cascaded MMI was investigated to fold the length of the duplexer as short as 117μm with the extinct ratio over 10dB.

  13. Cutting Whole Length or Partial Length of Internal Anal Sphincter in Managementof Fissure in Ano

    Directory of Open Access Journals (Sweden)

    Furat Shani Aoda

    2017-12-01

    Full Text Available A chronic anal fissure is a common painful perianal condition.The main operative procedure to treat this painful condition is a lateral internal sphincteretomy (LIS.The aim of study is to compare the outcome and complications of closed LIS up to the dentate line (whole length of internal sphincter or up to the fissure apex (partial length of internal sphincter in the treatment of anal fissure.It is a prospective comparativestudy including 100 patients with chronic fissure in ano. All patients assigned to undergo closed LIS. Those patients were randomly divided into two groups: 50 patients underwent LIS to the level of dentate line (whole length and other 50 patients underwent LIS to the level of fissure apex (partial length. Patients were followed up weekly in the 1st month, twice monthly in the second month then monthly   for next 2 months and finally after 1 year. There was satisfactory relief of pain in all patients in both groups & complete healing of the fissure occurred. Regarding post operative incontinence no major degree of incontinence occur in both group but minor degree of incontinence persists In 7 patients after whole length LIS after one year. In conclusion, both whole length & partial length LIS associated with improvement of pain, good chance of healing but whole length LIS associated with more chance of long term  flatus incontinence. Hence,we recommend partial length LIS as treatment forchronic anal fissure.

  14. Collective dynamics of glass-forming polymers at intermediate length scales

    International Nuclear Information System (INIS)

    Colmenero, J.; Alvarez, F.; Arbe, A.

    2015-01-01

    Deep understanding of the complex dynamics taking place in glass-forming systems could potentially be gained by exploiting the information provided by the collective response monitored by coherent neutron scattering. We have revisited the question of the characterization of the collective response of polyisobutylene at intermediate length scales observed by neutron spin echo (NSE) experiments. The model, generalized for sub-linear diffusion - as it is the case of glass-forming polymers - has been successfully applied by using the information on the total self-motions available from MD-simulations properly validated by direct comparison with experimental results. From the fits of the coherent NSE data, the collective time at Q → 0 has been extracted that agrees very well with compiled results from different experimental techniques directly accessing such relaxation time. We show that a unique temperature dependence governs both, the Q → 0 and Q → ∞ asymptotic characteristic times. The generalized model also gives account for the modulation of the apparent activation energy of the collective times with the static structure factor. It mainly results from changes of the short-range order at inter-molecular length scales

  15. The effect of recombination under short-circuit conditions on the determination of charge transport properties in nanostructured photoelectrodes.

    Science.gov (United States)

    Villanueva-Cab, J; Anta, J A; Oskam, G

    2016-01-28

    We report on the commonly unaccounted for process of recombination under short-circuit conditions in nanostructured photoelectrodes with special attention to the charge collection efficiency. It is observed that when recombination under short circuit conditions is significant, small perturbation methods overestimate the charge-collection efficiency, which is related to the inaccurate determination of the electron diffusion coefficient and diffusion length.

  16. Discoveries that guided the beginning of perpendicular magnetic recording

    International Nuclear Information System (INIS)

    Iwasaki, S.

    2001-01-01

    The speculations and discoveries that guided the beginning of perpendicular magnetic recording, which have never been systematically discussed before, are described in this paper. Especially, four important discoveries of perpendicular magnetization, Co-Cr film, effect of double layered medium, and complementarity law are described in detail. The studies on thin film media and recording mechanisms at short wavelengths aiming at the advancement of longitudinal magnetic recording in the 1960's lead to the realization of the new perpendicular magnetic recording through these discoveries. None of these works was on any list of research targets in the 1960's. The study of perpendicular magnetic recording has taught us that research should proceed systematically with definite targets and that it is important to have an attitude not to neglect phenomena that are different from the common sense at the time

  17. Factors related to axial length elongation and myopia progression in orthokeratology practice.

    Directory of Open Access Journals (Sweden)

    Bingjie Wang

    Full Text Available To investigate which baseline factors are predictive for axial length growth over an average period of 2.5 years in a group of children wearing orthokeratology (OK contact lenses.In this retrospective study, the clinical records of 249 new OK wearers between January 2012 and December 2013 from the contact lens clinic at the Eye and ENT Hospital of Fudan University were reviewed. The primary outcome measure was axial length change from baseline to the time of review (July-August 2015. Independent variables included baseline measures of age at initiation of OK wear, gender, refractive error (spherical equivalent, astigmatism, average keratometry, corneal toricity, central corneal thickness, white-to-white corneal diameter, pupil size, corneal topography eccentricity value (e-value, intraocular pressure (IOP and total time in follow-up (months total. The contributions of all independent variables on axial length change at the time of review were assessed using univariate and multivariable regression analyses.Univariate analyses of the right eyes of 249 OK patients showed that smaller increases in axial length were associated with older age at the onset of OK lens wear, greater baseline spherical equivalent myopic refractive error, less time in follow-up and a smaller e-value. Multivariable analyses of the significant right eye variables showed that the factors associated with smaller axial length growth were older age at the onset of OK lens wear (p<0.0001, greater baseline spherical equivalent myopic refractive error (p = 0.0046 and less time in follow-up (p<0.0001.The baseline factors demonstrating the greatest correlation with reduced axial length elongation during OK lens wear in myopic children included greater baseline spherical equivalent myopic refractive error and older age at the onset of OK lens wear.

  18. Quaternary magnetic excursions recorded in marine sediments.

    Science.gov (United States)

    Channell, J. E. T.

    2017-12-01

    This year is the golden (50th) anniversary of the first documentation of a magnetic excursion, the Laschamp excursion in volcanics from the Chaine des Puys (Bonhommet and Babkine, 1967). The first recording of an excursion in sediments was from the Blake Outer Ridge (Smith and Foster, 1969). Magnetic excursions are directional aberrations of the geomagnetic field apparently involving short-lived reversal of the main dipole field. They have durations of a few kyrs, and are therefore rarely recorded in sediments with mean sedimentation rates Palma), and 670 ka (Osaka Bay), implying at least 11 excursions in the Brunhes Chron. For the Matuyama Chron, excursions have been recorded in marine sediments at 868 ka (Kamikatsura?), 932 ka (Santa Rosa), 1051 ka (Intra-Jaramillo), 1115 ka (Punaruu), 1255 ka (Bjorn), 1476 ka (Gardar), 1580 ka (Gilsa), and 2737 ka (Porcupine). Excursions coincide with minima in relative paleointensity (RPI) records. Ages are from correlation of excursion records to oxygen isotope records in the same cores, and ice-volume calibration of the oxygen isotope template. The marine sediment record of excursions, combined with independent documentation of excursions in lavas with Ar/Ar age control, is progressively strengthening our knowledge of the excursion inventory in the Quaternary, and enhancing the importance of excursions and RPI in Quaternary stratigraphy.

  19. The Pleistocene Eastern Equatorial Pacific: Insights from a New Carnegie Platform Stratigraphic Record

    Science.gov (United States)

    Gwizd, S.; Lea, D. W.

    2016-12-01

    Renewed interest in a classic Eastern Equatorial Pacific paleoceanographic site at 3° 35.85' S, 83° 57.79' W, previous site of cores V19-29 and TR163-31, prompted a re-coring in 2009 using the recently developed CDH giant piston coring system on cruise KNR195-5. Giant piston core CDH-36 (3225 m depth, 42.61 m length) nearly triples the length of previous cores at this site. When spliced together with companion multicore MC-34A (0.36 m length), these two cores generate continuous stratigraphy throughout most of the middle Pleistocene, and include recognized stratigraphic tie points ash layer "L" (Ninkovich and Shackleton, 1975) and the extinction of pink G. ruber. A new age model utilizing Bayesian analysis of 17 N. dutertrei radiocarbon dates in MC-34A and the top 3.4 m of CDH-36, and alignment of a new CDH-36 δ18O record with the LR04 benthic stack (Lisiecki and Raymo, 2005), demonstrates that this new "Carnegie Platform" (CP) record extends from 0 to 720 ka (MIS 18), tripling the timescale of previous studies, with an average sedimentation rate of 7 cm/kyr. The CP C. wuellerstorfi δ18O and δ13C records reveal strong consistencies in timing and extent of glacial and interglacial episodes with previously studied regional records. Coarse fraction percentage (%CF) ([coarse fraction/bulk dry sample] * 100) is also evaluated throughout the CP core in order to qualitatively assess dissolution cycles. The CP %CF dataset primarily records Pleistocene dissolution cycles, yet exhibits variability representative of potential local bathymetric and hydrographic effects. The timing of %CF cyclicity is consistent with processes which affect basin-wide calcium carbonate dissolution cycles, including changes in terrestrial carbon input to the oceans and changes in water mass ventilation (Shackleton, 1977; Toggweiler et al., 2006; Sexton and Barker, 2012). Establishing the stratigraphy of the CP record provides the first step towards a more thorough and extended analysis of

  20. Why buy an album? The motivations behind recorded music purchases

    OpenAIRE

    Brown, Steven; Knox, Don

    2016-01-01

    The present study examined why music fans choose to buy recorded music given the multitude of other ways to listen to music without payment. A sample of 135 participants (68.88% female) with a mean age of 29.05 years completed an open-ended questionnaire. These written responses were analysed thematically. Two key themes were identified: Short-term comparisons, and Long-term considerations. Motivations focused on value-maximisation across both themes, with short-term comparisons including how...

  1. Effect of altering starting length and activation timing of muscle on fiber strain and muscle damage.

    Science.gov (United States)

    Butterfield, Timothy A; Herzog, Walter

    2006-05-01

    Muscle strain injuries are some of the most frequent injuries in sports and command a great deal of attention in an effort to understand their etiology. These injuries may be the culmination of a series of subcellular events accumulated through repetitive lengthening (eccentric) contractions during exercise, and they may be influenced by a variety of variables including fiber strain magnitude, peak joint torque, and starting muscle length. To assess the influence of these variables on muscle injury magnitude in vivo, we measured fiber dynamics and joint torque production during repeated stretch-shortening cycles in the rabbit tibialis anterior muscle, at short and long muscle lengths, while varying the timing of activation before muscle stretch. We found that a muscle subjected to repeated stretch-shortening cycles of constant muscle-tendon unit excursion exhibits significantly different joint torque and fiber strains when the timing of activation or starting muscle length is changed. In particular, measures of fiber strain and muscle injury were significantly increased by altering activation timing and increasing the starting length of the muscle. However, we observed differential effects on peak joint torque during the cyclic stretch-shortening exercise, as increasing the starting length of the muscle did not increase torque production. We conclude that altering activation timing and muscle length before stretch may influence muscle injury by significantly increasing fiber strain magnitude and that fiber dynamics is a more important variable than muscle-tendon unit dynamics and torque production in influencing the magnitude of muscle injury.

  2. Setting the Trajectory: Racial Disparities in Newborn Telomere Length

    Science.gov (United States)

    Drury, Stacy S.; Esteves, Kyle; Hatch, Virginia; Woodbury, Margaret; Borne, Sophie; Adamski, Alys; Theall, Katherine P.

    2015-01-01

    Objective To explore racial differences in newborn telomere length (TL) and the effect moderation of the sex of the infant while establishing the methodology for the use of newborn blood spots for telomere length analyses. Study design Pregnant mothers were recruited from the Greater New Orleans area. TL was determined using MMQ-PCR on DNA extracted from infant blood spots. Demographic data and other covariates were obtained via maternal report prior to infant birth. Birth outcome data were obtained from medical records and maternal report. Results Black infants weighed significantly less than white infants at birth, and had significantly longer TL than White infants (p=0.0134), with the strongest effect observed in Black female infants. No significant differences in gestational age were present. Conclusions Significant racial differences in TL were present at birth in this sample, even after controlling for a range of birth outcomes and demographic factors. As longer initial TL is predictive of more rapid TL attrition across the life course, these findings provide evidence that, even at birth, biological vulnerability to early life stress may differ by race and sex. PMID:25681203

  3. Evaluation of Short Term Memory Span Function In Children

    Directory of Open Access Journals (Sweden)

    Barış ERGÜL

    2016-12-01

    Full Text Available Although details of the information encoded in the short-term memory where it is stored temporarily be recorded in the working memory in the next stage. Repeating the information mentally makes it remain in memory for a long time. Studies investigating the relationship between short-term memory and reading skills that are carried out to examine the relationship between short-term memory processes and reading comprehension. In this study information coming to short-term memory and the factors affecting operation of short term memory are investigated with regression model. The aim of the research is to examine the factors (age, IQ and reading skills that are expected the have an effect on short-term memory in children through regression analysis. One of the assumptions of regression analysis is to examine which has constant variance and normal distribution of the error term. In this study, because the error term is not normally distributed, robust regression techniques were applied. Also, for each technique; coefficient of determination is determined. According to the findings, the increase in age, IQ and reading skills caused the increase in short term memory in children. After applying robust regression techniques, the Winsorized Least Squares (WLS technique gives the highest coefficient of determination.

  4. Analysis of trace elements in the shells of short-necked clam Ruditapes philippinarum (Mollusca: Bivalvia) with respect to reconstruction of individual life history

    International Nuclear Information System (INIS)

    Arakawa, Jumpei; Sakamoto, Wataru

    1998-01-01

    Strontium (Sr) concentration in the shells of short-necked clams collected at different locations (Shirahama, warm area and Maizuru, cold area, Japan) was analyzed by two methods, PIXE and EPMA. The Sr concentration of external surface of shell umbo, which was made during short term at early benthic phase, was analyzed by PIXE, and was ranged from 1000 to 3500 ppm for individuals. The Sr concentration of clams collected at Shirahama showed positive correlation with shell length (SL) in individuals with SL < 31 mm, whereas clams collected at Maizuru did not show significant correlation. This result may be caused from the difference of the spawning seasons between two areas. The Sr concentration of cross section of shell umbo, which develops thicker continuously during their life to form faint stratum structure, was analyzed by EPMA along the line across the stratum structure. Some surges and long term waving patterns of the Sr concentration were observed. These results suggest that the life histories of individual clams could be recorded in the shell umbo cross sections as variations of trace elements and analyses of trace elements could clarify the histories of individual clams. (author)

  5. Effect of temperature and cycle length on microbial competition in PHB-producing sequencing batch reactor.

    Science.gov (United States)

    Jiang, Yang; Marang, Leonie; Kleerebezem, Robbert; Muyzer, Gerard; van Loosdrecht, Mark C M

    2011-05-01

    The impact of temperature and cycle length on microbial competition between polyhydroxybutyrate (PHB)-producing populations enriched in feast-famine sequencing batch reactors (SBRs) was investigated at temperatures of 20 °C and 30 °C, and in a cycle length range of 1-18 h. In this study, the microbial community structure of the PHB-producing enrichments was found to be strongly dependent on temperature, but not on cycle length. Zoogloea and Plasticicumulans acidivorans dominated the SBRs operated at 20 °C and 30 °C, respectively. Both enrichments accumulated PHB more than 75% of cell dry weight. Short-term temperature change experiments revealed that P. acidivorans was more temperature sensitive as compared with Zoogloea. This is particularly true for the PHB degradation, resulting in incomplete PHB degradation in P. acidivorans at 20 °C. Incomplete PHB degradation limited biomass growth and allowed Zoogloea to outcompete P. acidivorans. The PHB content at the end of the feast phase correlated well with the cycle length at a constant solid retention time (SRT). These results suggest that to establish enrichment with the capacity to store a high fraction of PHB, the number of cycles per SRT should be minimized independent of the temperature.

  6. Comparison of shoe-length fit between people with and without diabetic peripheral neuropathy: a case–control study

    Directory of Open Access Journals (Sweden)

    McInnes Alistair D

    2012-04-01

    Full Text Available Abstract Background Amongst the many identified mechanisms leading to diabetic foot ulceration, ill-fitting footwear is one. There is anecdotal evidence that people with diabetic peripheral neuropathy wear shoes that are too small in order to increase the sensation of fit. The aim of this study was to determine whether people with diabetic sensory neuropathy wear appropriate length footwear. Methods A case–control design was used to compare internal shoe length and foot length differences between a group of people with diabetes and peripheral sensory neuropathy and a group of people without diabetes and no peripheral sensory neuropathy. Shoe and foot length measurements were taken using a calibrated Internal Shoe Size Gauge® and a Brannock Device®, respectively. Results Data was collected from 85 participants with diabetes and 118 participants without diabetes. The mean difference between shoe and foot length was not significantly different between the two groups. However, a significant number of participants within both groups had a shoe to foot length difference that lay outside a previously suggested 10 to 15 mm range. From the diabetic and non-diabetic groups 82% (70/85 and 66% (78/118, respectively had a foot to shoe length difference outside this same range. Conclusions This study shows that although there is no significant difference in shoe-length fit between participants with and without neuropathy, a significant proportion of these populations wear shoes that are either too long or too short for their foot length according to the 10 to 15 mm value used for comparison. The study has highlighted the need for standardised approaches when considering the allowance required between foot and internal shoe length and for the measurement and comparison of foot and shoe dimensions.

  7. Coating of carbon short fibers with thin ceramic layers by chemical vapor deposition

    International Nuclear Information System (INIS)

    Hackl, Gerrit; Gerhard, Helmut; Popovska, Nadejda

    2006-01-01

    Carbon short fiber bundles with a length of 6 mm were uniformly coated using specially designed, continuous chemical vapor deposition (CVD) equipment. Thin layers of titanium nitride, silicon nitride (SiC) and pyrolytic carbon (pyC) were deposited onto several kilograms of short fibers in this large scale CVD reactor. Thermo-gravimetric analyses and scanning electron microscopy investigations revealed layer thicknesses between 20 and 100 nm on the fibers. Raman spectra of pyC coated fibers show a change of structural order depending on the CVD process parameters. For the fibers coated with SiC, Raman investigations showed a deposition of amorphous SiC. The coated carbon short fibers will be applied as reinforcing material in composites with ceramic and metallic matrices

  8. Effect of Instrumentation Length and Instrumentation Systems: Hand Versus Rotary Files on Apical Crack Formation - An In vitro Study.

    Science.gov (United States)

    Devale, Madhuri R; Mahesh, M C; Bhandary, Shreetha

    2017-01-01

    Stresses generated during root canal instrumentation have been reported to cause apical cracks. The smaller, less pronounced defects like cracks can later propagate into vertical root fracture, when the tooth is subjected to repeated stresses from endodontic or restorative procedures. This study evaluated occurrence of apical cracks with stainless steel hand files, rotary NiTi RaCe and K3 files at two different instrumentation lengths. In the present in vitro study, 60 mandibular premolars were mounted in resin blocks with simulated periodontal ligament. Apical 3 mm of the root surfaces were exposed and stained using India ink. Preoperative images of root apices were obtained at 100x using stereomicroscope. The teeth were divided into six groups of 10 each. First two groups were instrumented with stainless steel files, next two groups with rotary NiTi RaCe files and the last two groups with rotary NiTi K3 files. The instrumentation was carried out till the apical foramen (Working Length-WL) and 1 mm short of the apical foramen (WL-1) with each file system. After root canal instrumentation, postoperative images of root apices were obtained. Preoperative and postoperative images were compared and the occurrence of cracks was recorded. Descriptive statistical analysis and Chi-square tests were used to analyze the results. Apical root cracks were seen in 30%, 35% and 20% of teeth instrumented with K-files, RaCe files and K3 files respectively. There was no statistical significance among three instrumentation systems in the formation of apical cracks (p=0.563). Apical cracks were seen in 40% and 20% of teeth instrumented with K-files; 60% and 10% of teeth with RaCe files and 40% and 0% of teeth with K3 files at WL and WL-1 respectively. For groups instrumented with hand files there was no statistical significance in number of cracks at WL and WL-1 (p=0.628). But for teeth instrumented with RaCe files and K3 files significantly more number of cracks were seen at WL than

  9. CMOS Receiver Front-ends for Gigabit Short-Range Optical Communications

    CERN Document Server

    Aznar, Francisco; Calvo Lopez, Belén

    2013-01-01

    This book describes optical receiver solutions integrated in standard CMOS technology, attaining high-speed short-range transmission within cost-effective constraints.  These techniques support short reach applications, such as local area networks, fiber-to-the-home and multimedia systems in cars and homes. The authors show how to implement the optical front-end in the same technology as the subsequent digital circuitry, leading to integration of the entire receiver system in the same chip.  The presentation focuses on CMOS receiver design targeting gigabit transmission along a low-cost, standardized plastic optical fiber up to 50m in length.  This book includes a detailed study of CMOS optical receiver design – from building blocks to the system level. Reviews optical communications, including long-haul transmission systems and emerging applications focused on short-range; Explains necessary fundamentals, such as characteristics of a data signal, system requirements affecting receiver design and key par...

  10. O esôfago curto e o refluxo distal são fatores de risco para o refluxo proximal? Short length of the esophagus and distal reflux are risk factors for proximal esophageal reflux?

    Directory of Open Access Journals (Sweden)

    Humberto Oliveira Serra

    2010-12-01

    Full Text Available RACIONAL: Não está claro se pacientes que apresentam refluxo gastroesofágico distal têm maior risco de apresentar também refluxo proximal. O senso comum sugere que um episódio de refluxo poderia chegar mais facilmente à faringe em pacientes que tivessem menor distância a percorrer entre o esfíncter inferior do esôfago e o superior. OBJETIVO: Investigar se o esôfago curto e a presença de refluxo esofágico distal são fatores de risco para refluxo proximal nos pacientes com sintomas respiratórios. MÉTODO: Cento e sete pacientes foram avaliados prospectivamente por meio de entrevista, esofagoscopia, manometria e pHmetria. Utilizaram-se o teste t de Student, o de correlação de Spearman, o do Qui-quadrado e odds-ratio. O nível de significância foi 0,05. RESULTADOS: Os sintomas que motivaram a investigação da doença do refluxo gastroesofágico foram: tosse 43 (40,2%; pigarro 25 (23,4%, globo faríngeo 23 (21,5% e rouquidão 16 (14,9%. No estudo endoscópico 22 apresentaram esofagite e 14 hérnia de hiato. Na avaliação manométrica 11 (10,8% apresentaram hipotonia do esfíncter inferior. A média do comprimento do esôfago foi 24,3 (± 1,9 cm, variando de 20 a 30 cm. Na avaliação pHmétrica 23 (21,5% apresentaram refluxo distal patológico e 12 (11,2% refluxo proximal. CONCLUSÕES: O comprimento do esôfago não esteve associado com a presença de refluxo proximal. Pacientes que apresentaram refluxo gatroesofágico distal, independente do comprimento do esôfago, tiveram risco aumentado de 4,6 vezes para apresentarem refluxo proximal.BACKGROUND: It is not clear whether patients suffering from distal esophageal reflux also present high risk to proximal esophageal reflux. Common sense suggests that reflux would more easily reach the pharynx in patients who have a smaller distance between the lower esophageal sphincter and the upper one and, thus, short esophagus. AIM: To Investigate if short esophageal length and presence of

  11. Seat Capacity Selection for an Advanced Short-Haul Aircraft Design

    Science.gov (United States)

    Marien, Ty V.

    2016-01-01

    A study was performed to determine the target seat capacity for a proposed advanced short-haul aircraft concept projected to enter the fleet by 2030. This analysis projected the potential demand in the U.S. for a short-haul aircraft using a transportation theory approach, rather than selecting a target seat capacity based on recent industry trends or current market demand. A transportation systems model was used to create a point-to-point network of short-haul trips and then predict the number of annual origin-destination trips on this network. Aircraft of varying seat capacities were used to meet the demand on this network, assuming a single aircraft type for the entire short-haul fleet. For each aircraft size, the ticket revenue and operational costs were used to calculate a total market profitability metric for all feasible flights. The different aircraft sizes were compared, based on this market profitability metric and also the total number of annual round trips and markets served. Sensitivity studies were also performed to determine the effect of changing the aircraft cruise speed and maximum trip length. Using this analysis, the advanced short-haul aircraft design team was able to select a target seat capacity for their design.

  12. Communication disruption of guava moth (Coscinoptycha improbana) using a pheromone analog based on chain length.

    Science.gov (United States)

    Suckling, D M; Dymock, J J; Park, K C; Wakelin, R H; Jamieson, L E

    2013-09-01

    The guava moth, Coscinoptycha improbana, an Australian species that infests fruit crops in commercial and home orchards, was first detected in New Zealand in 1997. A four-component pheromone blend was identified but is not yet commercially available. Using single sensillum recordings from male antennae, we established that the same olfactory receptor neurons responded to two guava moth sex pheromone components, (Z)-11-octadecen-8-one and (Z)-12-nonadecen-9-one, and to a chain length analog, (Z)-13-eicosen-10-one, the sex pheromone of the related peach fruit moth, Carposina sasakii. We then field tested whether this non-specificity of the olfactory neurons might enable disruption of sexual communication by the commercially available analog, using male catch to synthetic lures in traps in single-tree, nine-tree and 2-ha plots. A disruptive pheromone analog, based on chain length, is reported for the first time. Trap catches for guava moth were disrupted by three polyethylene tubing dispensers releasing the analog in single-tree plots (86% disruption of control catches) and in a plots of nine trees (99% disruption). Where peach fruit moth pheromone dispensers were deployed at a density of 1000/ha in two 2-ha areas, pheromone traps for guava moth were completely disrupted for an extended period (up to 470 days in peri-urban gardens in Mangonui and 422 days in macadamia nut orchards in Kerikeri). In contrast, traps in untreated areas over 100 m away caught 302.8 ± 128.1 moths/trap in Mangonui and 327.5 ± 78.5 moths/ trap in Kerikeri. The longer chain length in the pheromone analog has greater longevity than the natural pheromone due to its lower volatility. Chain length analogs may warrant further investigation for mating disruption in Lepidoptera, and screening using single-sensillum recording is recommended.

  13. Short-term plasticity as a neural mechanism supporting memory and attentional functions.

    Science.gov (United States)

    Jääskeläinen, Iiro P; Ahveninen, Jyrki; Andermann, Mark L; Belliveau, John W; Raij, Tommi; Sams, Mikko

    2011-11-08

    Based on behavioral studies, several relatively distinct perceptual and cognitive functions have been defined in cognitive psychology such as sensory memory, short-term memory, and selective attention. Here, we review evidence suggesting that some of these functions may be supported by shared underlying neuronal mechanisms. Specifically, we present, based on an integrative review of the literature, a hypothetical model wherein short-term plasticity, in the form of transient center-excitatory and surround-inhibitory modulations, constitutes a generic processing principle that supports sensory memory, short-term memory, involuntary attention, selective attention, and perceptual learning. In our model, the size and complexity of receptive fields/level of abstraction of neural representations, as well as the length of temporal receptive windows, increases as one steps up the cortical hierarchy. Consequently, the type of input (bottom-up vs. top down) and the level of cortical hierarchy that the inputs target, determine whether short-term plasticity supports purely sensory vs. semantic short-term memory or attentional functions. Furthermore, we suggest that rather than discrete memory systems, there are continuums of memory representations from short-lived sensory ones to more abstract longer-duration representations, such as those tapped by behavioral studies of short-term memory. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Smoking and perceived stress in relation to short salivary telomere length among caregivers of children with disabilities.

    Science.gov (United States)

    Chen, Xiaoli; Velez, Juan Carlos; Barbosa, Clarita; Pepper, Micah; Andrade, Asterio; Stoner, Lee; De Vivo, Immaculata; Gelaye, Bizu; Williams, Michelle A

    2015-01-01

    Telomere length (TL), the length of repeated DNA sequence that forms protective caps at the end of chromosomes, has emerged as a novel biomarker of cell aging and oxidative stress. There is increasing research exploring the associations of smoking and perceived stress with TL, and the results are inconsistent. This study aimed to examine whether smoking and perceived stress were associated with shortened salivary TL among primary caregivers of children with disabilities. Using a quantitative polymerase chain reaction method, salivary TL was assessed among 89 caregivers aged 19-69 years (87% were women) who took care of disabled children in the Patagonia Region, Chile. Interviewer-administered questionnaires were used to collect information on sociodemographic and lifestyle factors. The 14-item Perceived Stress Scale was used to assess perceived stress. Mean relative TL was 0.92 (standard error = 0.03). Smokers had age-adjusted mean TL that was 0.07 units lower (β = -0.07, standard error = 0.03; p = 0.012) than non-smokers. Smokers were 2.17 times more likely to have shorter TL ( stress. Caregivers with higher perceived stress were 2.13 times more likely to have shorter TL (odds ratio = 3.13; 95% confidence interval = 1.03-9.55) than caregivers with lower perceived stress after adjustment for age and smoking. This study provides the first evidence of strong associations between smoking and perceived stress and shortened salivary TL among caregivers of children with disabilities. Larger studies with detailed information on smoking status are warranted to confirm our findings.

  15. Freely cooling granular gases with short-ranged attractive potentials

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, Eric; Subramaniam, Shankar, E-mail: shankar@iastate.edu [Department of Mechanical Engineering, Center for Multiphase Flow Research, Iowa State University, Ames, Iowa 50011 (United States)

    2015-04-15

    We treat the case of an undriven gas of inelastic hard-spheres with short-ranged attractive potentials via an extension of the pseudo-Liouville operator formalism. New evolution equations for the granular temperature and coordination number are obtained. The granular temperature exhibits deviation from both Haff’s law and the case of long-ranged potentials. We verify this departure using soft-sphere discrete element method simulations. Excellent agreement is found for the duration of the simulation even beyond where exclusively binary collisions are expected. Simulations show the emergence of strong spatial-velocity correlations on the length scale of the last peak in the pair-correlation function but do not show strong correlations beyond this length scale. We argue that molecular chaos may remain an adequate approximation if the system is modelled as a Smoluchowski type equation with aggregation and break-up processes.

  16. Nesting behavior of Palila, as assessed from video recordings

    Science.gov (United States)

    Laut, M.E.; Banko, P.C.; Gray, E.M.

    2003-01-01

    We quantified nesting behavior of Palila (Loxiodes bailleui), an endangered Hawaiian honeycreeper, by recording at nests during three breeding seasons using a black-and-white video camera connected to a Videocassette recorder. A total of seven nests was observed. We measured the following factors for daylight hours: percentage of time the female was on the nest (attendance), length of attendance bouts by the female, length of nest recesses, and adult provisioning rates. Comparisons were made between three stages of the 40-day nesting cycle: incubation (day 1-day 16), early nestling stage (day 17-day 30 [i.e., nestlings ??? 14 days old]), and late nestling stage (day 31-day 40 [i.e., nestlings > 14 days old]). Of seven nests observed, four fledged at least one nestling and three failed. One of these failed nests was filmed being depredated by a feral cat (Felis catus). Female nest attendance was near 82% during the incubation stage and decreased to 21% as nestlings aged. We did not detect a difference in attendance bout length between stages of the nesting cycle. Mean length of nest recesses increased from 4.5 min during the incubation stage to over 45 min during the late nestling stage. Mean number of nest recesses per hour ranged from 1.6 to 2.0. Food was delivered to nestlings by adults an average of 1.8 times per hour for the early nestling stage and 1.5 times per hour during the late nestling stage and did not change over time. Characterization of parental behavior by video had similarities to but also key differences from findings taken from blind observations. Results from this study will facilitate greater understanding of Palila reproductive strategies.

  17. High-Specificity Targeted Functional Profiling in Microbial Communities with ShortBRED.

    Directory of Open Access Journals (Sweden)

    James Kaminski

    2015-12-01

    Full Text Available Profiling microbial community function from metagenomic sequencing data remains a computationally challenging problem. Mapping millions of DNA reads from such samples to reference protein databases requires long run-times, and short read lengths can result in spurious hits to unrelated proteins (loss of specificity. We developed ShortBRED (Short, Better Representative Extract Dataset to address these challenges, facilitating fast, accurate functional profiling of metagenomic samples. ShortBRED consists of two components: (i a method that reduces reference proteins of interest to short, highly representative amino acid sequences ("markers" and (ii a search step that maps reads to these markers to quantify the relative abundance of their associated proteins. After evaluating ShortBRED on synthetic data, we applied it to profile antibiotic resistance protein families in the gut microbiomes of individuals from the United States, China, Malawi, and Venezuela. Our results support antibiotic resistance as a core function in the human gut microbiome, with tetracycline-resistant ribosomal protection proteins and Class A beta-lactamases being the most widely distributed resistance mechanisms worldwide. ShortBRED markers are applicable to other homology-based search tasks, which we demonstrate here by identifying phylogenetic signatures of antibiotic resistance across more than 3,000 microbial isolate genomes. ShortBRED can be applied to profile a wide variety of protein families of interest; the software, source code, and documentation are available for download at http://huttenhower.sph.harvard.edu/shortbred.

  18. Capillary electrophoretic analysis of synthetic short-chain oligoribonucleotides.

    Science.gov (United States)

    Cellai, L; Onori, A M; Desiderio, C; Fanali, S

    1998-12-01

    Thirty synthetic oligoribonucleotides, 3 to 18 nucleotides (nt) long, were analyzed by capillary electrophoresis, under nondenaturing conditions, using a commercial kit. The migration time t(m) was dependent on nt length and composition, capillary length, operating temperature, and type of sieving polymer. Under fixed experimental conditions, the t(m) proved predictable by the equation: t(m) = [0.22(n-1) + 6.14A/n + 6.86G/n + 3.61 (C+U)/n] min, for n>3, where A/n, G/n, C/n, U/n is the frequency of each type of nt within the oligonucleotide (ONT). The equation accounts for the influence of charge-to-mass ratio on t(m), but not for structural effects, if present. This approximation is acceptable for short ONTs. The possibility of detecting n+1, n-1, n-2 impurities, having predicted the t(m), is of crucial importance in assessing the purity of synthetic ONTs dedicated to structural studies. This appears to be feasible. High resolution was shown among homologous series of ONTs of increasing length, and in some cases, even within groups of ONTs of the same length but different composition. The addition of 7 M urea to the buffer, as denaturing agent, accelerates the t(m) and significantly lowers the resolution for the shortest ONTs. It was also possible to monitor the state of association of mixtures of RNA and DNA sequence-complementary strands.

  19. ISRNA: an integrative online toolkit for short reads from high-throughput sequencing data.

    Science.gov (United States)

    Luo, Guan-Zheng; Yang, Wei; Ma, Ying-Ke; Wang, Xiu-Jie

    2014-02-01

    Integrative Short Reads NAvigator (ISRNA) is an online toolkit for analyzing high-throughput small RNA sequencing data. Besides the high-speed genome mapping function, ISRNA provides statistics for genomic location, length distribution and nucleotide composition bias analysis of sequence reads. Number of reads mapped to known microRNAs and other classes of short non-coding RNAs, coverage of short reads on genes, expression abundance of sequence reads as well as some other analysis functions are also supported. The versatile search functions enable users to select sequence reads according to their sub-sequences, expression abundance, genomic location, relationship to genes, etc. A specialized genome browser is integrated to visualize the genomic distribution of short reads. ISRNA also supports management and comparison among multiple datasets. ISRNA is implemented in Java/C++/Perl/MySQL and can be freely accessed at http://omicslab.genetics.ac.cn/ISRNA/.

  20. Impact of Generator Stroke Length on Energy Production for a Direct Drive Wave Energy Converter

    Directory of Open Access Journals (Sweden)

    Yue Hong

    2016-09-01

    Full Text Available The Lysekil wave energy converter (WEC, developed by the wave energy research group of Uppsala University, has evolved through a variety of mechanical designs since the first prototype was installed in 2006. The hundreds of engineering decisions made throughout the design processes have been based on a combination of theory, know-how from previous experiments, and educated guesses. One key parameter in the design of the WECs linear generator is the stroke length. A long stroke requires a taller WEC with associated economical and mechanical challenges, but a short stroke limits the power production. The 2-m stroke of the current WECs has been an educated guess for the Swedish wave climate, though the consequences of this choice on energy absorption have not been studied. When the WEC technology is considered for international waters, with larger waves and challenges of energy absorption and survivability, the subject of stroke length becomes even more relevant. This paper studies the impact of generator stroke length on energy absorption for three sites off the coasts of Sweden, Chile and Scotland. 2-m, 4-m, and unlimited stroke are considered. Power matrices for the studied WEC prototype are presented for each of the studied stroke lengths. Presented results quantify the losses incurred by a limited stroke. The results indicate that a 2-m stroke length is likely to be a good choice for Sweden, but 4-m is likely to be necessary in more energetic international waters.