WorldWideScience

Sample records for short plasma half-life

  1. Vitamin E plasma kinetics in swine show low bioavailability and short half-life of -α-tocopheryl acetate.

    Science.gov (United States)

    van Kempen, T A T G; Reijersen, M H; de Bruijn, C; De Smet, S; Michiels, J; Traber, M G; Lauridsen, C

    2016-10-01

    Vitamin E is important for animal production because of its effects on health and product quality, but the amount and form required remains controversial. Our objective was to quantify the absolute bioavailability of oral -α-tocopheryl acetate (α-TAc) in swine (22 ± 1 kg and 8 wk old, fitted with jugular catheters) adapted to a diet supplemented with 75 mg/kg -α-TAc; 75 mg/kg was chosen because this level represents the nonweighted average inclusion level in piglet diets across Western key swine-producing countries. For this, a 350-g test meal (6% fat) was supplied at time 0 containing 75 mg deuterated (D9) -α-TAc to 9 animals, and 8 animals received an intravenous () dose containing deuterated (D6) RRR-α-tocopherol (α-T) at one-eighth the oral dose and a test meal without supplemental vitamin E. Plasma samples (12 to 13 per animal) were obtained at incremental intervals over 75 h for analysis of deuterated α-T using liquid chromatography-tandem mass spectrometry. Surprisingly, the i.v. dose rapidly disappeared from plasma and then reappeared. The half-life for this first peak was only 1.7 ± 0.3 min. The second peak had an appearance rate (Ka) of 0.10 ± 0.06 d and a half-life of 5.9 ± 1.2 h. Oral dosing resulted, after a lag of 56 min, in a Ka of 0.91 ± 0.21 d and a half-life of 2.6 ± 0.8 h. The bioavailability for oral α-TAc was 12.5%, whereas the area under the curve was only 5.4%. This low bioavailability, small area under the curve, and short half-life are likely because of various factors, that is, the use of only 6% fat in the diet, the use of the acetate ester and , and the high dose relative to requirements. In conclusion, i.v. dosed vitamin E shows both a rapid and a very slow pool, whereas orally dosed vitamin E shows a single slow pool. The oral material has a very short half-live (44% of i.v. or 2.6 h), low bioavailability (12.5%), and a very small area under the curve (5.4%), bringing into question the efficacy of typical doses of vitamin

  2. ESOL facility for the generation and radiochemical separation of short half-life fission products

    International Nuclear Information System (INIS)

    Gehrke, R.J.; Meikrantz, D.H.; Baker, J.D.; Anderl, R.A.; Novick, V.J.; Greenwood, R.C.

    1988-01-01

    A facility has been developed at the Idaho National Engineering Laboratory (INEL) for the generation and rapid radiochemical separation of short half-life mixed fission products. This facility, referred to as the Idaho Elemental Separation On Line (ESOL), consists of electro-plated sources of spontaneously fissioning 252 Cf with a helium jet transport arrangement to continuously deliver short half-life, mixed fission products to the radiochemistry laboratory for rapid, computer controlled, radiochemical separations. 18 refs., 13 figs

  3. Variation in absorption and half-life of hydrocortisone influence plasma cortisol concentrations.

    Science.gov (United States)

    Hindmarsh, Peter C; Charmandari, Evangelia

    2015-04-01

    Hydrocortisone therapy should be individualized in congenital adrenal hyperplasia (CAH) patients to avoid over and under replacement. We have assessed how differences in absorption and half-life of cortisol influence glucocorticoid exposure. Forty-eight patients (21 M) aged between 6·1 and 20·3 years with CAH due to CYP21A2 deficiency were studied. Each patient underwent a 24-h plasma cortisol profile with the morning dose used to calculate absorption parameters along with an intravenous (IV) hydrocortisone (15 mg/m(2) body surface area) bolus assessment of half-life. Parameters derived were maximum plasma concentration (Cmax ), time of maximum plasma concentration (tmax ), time to attaining plasma cortisol concentration cortisol. Mean half-life was 76·5 ± 5·2 (range 40-225·3) min, Cmax 780·7 ± 61·6 nmol/l and tmax 66·7 (range 20-118) min. Time taken to a plasma cortisol concentration less than 100 nmol/l was 289 (range 140-540) min. Those with a fast half-life and slow tmax took longest to reach a plasma cortisol concentration less than 100 nmol/l (380 ± 34·6 min), compared to those with a slow half-life and fast tmax (298 ± 34·8 min) and those with a fast half-life and fast tmax (249·5 ± 14·4 min) (One-way anovaF = 4·52; P = 0·009). Both rate of absorption and half-life of cortisol in the circulation play important roles in determining overall exposure to oral glucocorticoid. Dose regimens need to incorporate estimates of these parameters into determining the optimum dosing schedule for individuals. © 2014 John Wiley & Sons Ltd.

  4. Micooprecessor controlled facility for I.N.A.A. using short half life nuclides

    International Nuclear Information System (INIS)

    Bode, P.; Korthoven, P.J.M.; Bruin, M. de

    1986-01-01

    At IRI a new, fully atomated facility for short half life INAA is being developed and installed at the Institute 2 MW reactor. The fast rabbit transfer system is constructed only of plastic and carbonfiber parts, so that rabbit contamination is minimized. This system is automated in such a way that it can operate safely without direct supervision; the sequence of irradiations and measurements is optimized by a computer-program for a given set of samples and analysis procedures. The rabbit system is controlled by an Apple IIe-computer connected to the central PDP 11/44 system of the Radiochemistry department. For a given set of samples and required analysis procedures (irradiation-,decay-, and measurement times) the central computer calculates an optimal sequence of individual actions (transfer from and to the reactor, sample storage of detector) to be carried out by the system. This sequence is loaded into the Apple-computer as a series of commands together with timing information. Actual control of the procedure occurs through the peripheral computer, which makes the system independent of delays or break-downs of the central multi-user computer system. Hardware, software and operating characteristics of the fast rabbit system will be discussed. (author)

  5. Fast renal trapping of porcine Luteinizing Hormone (pLH shown by 123I-scintigraphic imaging in rats explains its short circulatory half-life

    Directory of Open Access Journals (Sweden)

    Locatelli Alain

    2003-10-01

    Full Text Available Abstract Background Sugar moieties of gonadotropins play no primary role in receptor binding but they strongly affect their circulatory half-life and consequently their in vivo biopotencies. In order to relate more precisely hepatic trapping of these glycoproteic hormones with their circulatory half-life, we undertook a comparative study of the distribution and elimination of porcine LH (pLH and equine CG (eCG which exhibit respectively a short and a long half-life. This was done first by following half-lives of pLH in piglets with hepatic portal circulation shunted or not. It was expected that such a shunt would enhance the short half-life of pLH. Subsequently, scintigraphic imaging of both 123I-pLH and 123I-eCG was performed in intact rats to compare their routes and rates of distribution and elimination. Methods Native pLH or eCG was injected to normal piglets and pLH was tested in liver-shunted anæsthetized piglet. Blood samples were recovered sequentially over one hour time and the hormone concentrations were determined by a specific ELISA method. Scintigraphic imaging of 123I-pLH and 123I-eCG was performed in rats using a OPTI-CGR gamma camera. Results In liver-shunted piglets, the half-life of pLH was found to be as short as in intact piglets (5 min. In the rat, the half-life of pLH was also found to be very short (3–6 min and 123I-pLH was found to accumulate in high quantity in less than 10 min post injection at the level of kidneys but not in the liver. 123I-eCG didn't accumulate in any organ in the rats during the first hour, plasma concentrations of this gonadotropin being still elevated (80% at this time. Conclusion In both the porcine and rat species, the liver is not responsible for the rapid elimination of pLH from the circulation compared to eCG. Our scintigraphic experiments suggest that the very short circulatory half-life of LH is due to rapid renal trapping.

  6. The antitumor agent 3-bromopyruvate has a short half-life at physiological conditions.

    Science.gov (United States)

    Glick, Matthew; Biddle, Perry; Jantzi, Josh; Weaver, Samantha; Schirch, Doug

    2014-09-12

    Clinical research is currently exploring the validity of the anti-tumor candidate 3-bromopyruvate (3-BP) as a novel treatment for several types of cancer. However, recent publications have overlooked rarely-cited earlier work about the instability of 3-BP and its decay to 3-hydroxypyruvate (3-HP) which have obvious implications for its mechanism of action against tumors, how it is administered, and for precautions when preparing solutions of 3-BP. This study found the first-order decay rate of 3-BP at physiological temperature and pH has a half-life of only 77 min. Lower buffer pH decreases the decay rate, while choice of buffer and concentration do not affect it. A method for preparing more stable solutions is also reported. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Determination of short half-life elements in biological, foodstuff, and environmental samples qualitatively by neutron activation analysis

    International Nuclear Information System (INIS)

    Syukria Kurniawati; Muhayatun Santoso; Diah Dwiana Lestiani

    2010-01-01

    NAA applications at routine operation power of 15 MW at Multipurpose Reactor GA Siwabessy (MPR-GAS) for sample matrices analysis have been widely applied. However, the results are not optimum for some matrices especially for short half-live elements. Preliminary study of short half-life elements determination in biological, foodstuff, and environmental samples using 1 MW power have been conducted to solve this problem. The samples were irradiated in rabbit system of MPR-GAS for 5 minutes, counted for 200 seconds by HPGe detector, and the spectrum were analyzed further using software Genie 2000 and Bandung NAA Utility. Analysis under 1 MW power on biological and foodstuff samples were capable to detect eight elements: Al, Br, CI, Ca, I, K, Mg, Ti, and Na for biological samples; Al, Br, CI, Ca, I, K, Mg, Mn, and Na for foodstuff samples, while at 15 MW power only three elements (CI, K, Na) were detected. At 1 MW power the counting process is more optimum due to smaller radiation exposure and dead time. For the environmental samples, the number of elements detected by 1 MW and 15 MW powers did not differ significantly. Generally, the results on the three types of samples showed that the elements of short half-life are better detected at 1 MW than that of 15 MW power. Further research needs to be done to obtain the optimum analytical conditions for irradiation and counting time determination. (author)

  8. Innovative methodology for intercomparison of radionuclide calibrators using short half-life in situ prepared radioactive sources

    International Nuclear Information System (INIS)

    Oliveira, P. A.; Santos, J. A. M.

    2014-01-01

    Purpose: An original radionuclide calibrator method for activity determination is presented. The method could be used for intercomparison surveys for short half-life radioactive sources used in Nuclear Medicine, such as 99m Tc or most positron emission tomography radiopharmaceuticals. Methods: By evaluation of the resulting net optical density (netOD) using a standardized scanning method of irradiated Gafchromic XRQA2 film, a comparison of the netOD measurement with a previously determined calibration curve can be made and the difference between the tested radionuclide calibrator and a radionuclide calibrator used as reference device can be calculated. To estimate the total expected measurement uncertainties, a careful analysis of the methodology, for the case of 99m Tc, was performed: reproducibility determination, scanning conditions, and possible fadeout effects. Since every factor of the activity measurement procedure can influence the final result, the method also evaluates correct syringe positioning inside the radionuclide calibrator. Results: As an alternative to using a calibrated source sent to the surveyed site, which requires a relatively long half-life of the nuclide, or sending a portable calibrated radionuclide calibrator, the proposed method uses a source preparedin situ. An indirect activity determination is achieved by the irradiation of a radiochromic film using 99m Tc under strictly controlled conditions, and cumulated activity calculation from the initial activity and total irradiation time. The irradiated Gafchromic film and the irradiator, without the source, can then be sent to a National Metrology Institute for evaluation of the results. Conclusions: The methodology described in this paper showed to have a good potential for accurate (3%) radionuclide calibrators intercomparison studies for 99m Tc between Nuclear Medicine centers without source transfer and can easily be adapted to other short half-life radionuclides

  9. Development of controller of acquisition and sample positioner for activation for use in measurements of short half-life radioisotopes

    International Nuclear Information System (INIS)

    Secco, Marcello

    2016-01-01

    High resolution gamma spectroscopy measurements have several applications. Those involving short half-life radioisotope measurements may present low precision problems when the radioactive source is far from detector end cup and in the very high activity situations also can present accuracy loss due to dead time and pile-up effects. A way to overcome these problems is changing the source detector distance as the activity is decreasing, and thereby maximizing the statistical counting. In the present study, the Controller of Acquisition and Sample Positioner for Activation (CASPA) was developed. It is a low cost and weight device, made with low atomic number materials designed to assist gamma spectroscopy measurements, which is able to control the distance between the source and the detector, even allowing that there is a change of this distance during the measurement process. Because it is automated it optimizes the time of the operator, who has complete freedom to program their routine measurements in the device besides minimizing the radiation dose in the operator. An interface that allow the user control the CASPA system and to program the acquisition system was created. Tests aiming to optimize the operation of CASPA system were carried out and the safety of the CASPA operation was verified, it was not presented any failure during their tests. It was applied the repeatability tests by the acquisition 60 Co standard source and was found that the positioning of automated system has reproduced the results of static system with a 95% of confidence level. (author)

  10. Analytical studies by activation. Part A and B: Counting of short half-life radio-nuclides. Part C: Analytical programs for decay curves

    International Nuclear Information System (INIS)

    Junod, E.

    1966-03-01

    Part A and B: Since a radio-nuclide of short half-life is characterized essentially by the decrease in its activity even while it is being measured, the report begins by recalling the basic relationships linking the half-life the counting time, the counting rate and the number of particles recorded. The second part is devoted to the problem of corrections for counting losses due to the idle period of multichannel analyzers. Exact correction formulae have been drawn up for the case where the short half-life radionuclide is pure or contains only a long half-life radio-nuclide. By comparison, charts have been drawn up showing the approximations given by the so-called 'active time' counting and by the counting involving the real time associated with a measurement of the overall idle period, this latter method proving to be more valid than the former. A method is given for reducing the case of a complex mixture to that of a two-component mixture. Part C: The problems connected with the qualitative and quantitative analysis of the decay curves of a mixture of radioactive sources of which one at least has a short half-life are presented. A mathematical description is given of six basic processes for which some elements of Fortran programs are proposed. Two supplementary programs are drawn up for giving an overall treatment of problems of dosage in activation analysis: one on the basis of a simultaneous irradiation of the sample and of one or several known samples, the other with separate irradiation of the unknown and known samples, a dosimeter (activation, or external) being used for normalizing the irradiation flux conditions. (author) [fr

  11. Propose of a model for dose and hazard calculation due the Rn-222, Rn-220 and its short half-life daugthers inhalation

    International Nuclear Information System (INIS)

    Mauricio, C.L.P.

    1982-01-01

    The compartimental dosimetric model is used to simulate, by computer, the interactions of the inhalated radon atom radiations and its short half-life daugthers with cells. The metabolic trajectory of these radionuclides is described by differential equations of continuous medium dynamics, where the elements transform by radioactive decay. This work permits to determine the individual retenction function, beeing useful in radioprotection routines or emergence situations. The results of internal dosimetry are consistent with the new I.C.R.P. - 32 international recommendations. (L.C.) [pt

  12. Half-life and mass measurement of the short-lived {sup 215}Po isotope (1.78 ms) at the FRS ion catcher

    Energy Technology Data Exchange (ETDEWEB)

    Rink, Ann-Kathrin; Bergmann, Julian; Ebert, Jens; Hornung, Christine; Miskun, Ivan; Reiter, Moritz P. [Justus-Liebig Universitaet Giessen (Germany); Ayet San Andres, Samuel; Dickel, Timo; Plass, Wolfgang R.; Scheidenberger, Christoph [Justus-Liebig Universitaet Giessen (Germany); GSI, Darmstadt (Germany); Geissel, Hans; Purushothaman, Sivaji [GSI, Darmstadt (Germany)

    2016-07-01

    At the Low-Energy Branch (LEB) of the Super-FRS at FAIR, precision experiments with exotic nuclei will be performed using ion traps and lasers. The nuclei will be produced at relativistic energies, slowed down, thermalised in a cryogenic stopping cell (CSC) and made available to various experiments. The thermalisation is a challenging task because of the large energy straggling of the nuclei after production, which requires a stopping cell with large areal densities. Also, the process needs to be performed on a millisecond time scale in order to give access to short-lived nuclides. This method has already been successfully applied at the FRS Ion Catcher at GSI using a prototype CSC. Recently the potential of the method has been demonstrated by the mass and half-life measurement of the {sup 215}Po nuclide with a half-life of 1.78 ms only. The multiple-reflection time-of-flight mass spectrometer at the FRS Ion Catcher has been used to determine the mass to a sub-ppm accuracy and to provide a mass-selected beam for alpha spectroscopy. Furthermore, experiments have been performed with the prototype CSC in order to test novel concepts to be used with the final version of the CSC for the LEB.

  13. Increased volume of distribution for recombinant activated factor VII and longer plasma-derived factor VII half-life may explain their long lasting prophylactic effect.

    Science.gov (United States)

    Mathijssen, Natascha C J; Masereeuw, Rosalinde; Holme, Pal Andre; van Kraaij, Marian G J; Laros-van Gorkom, Britta A P; Peyvandi, Flora; van Heerde, Waander L

    2013-08-01

    Prophylaxis with plasma-derived or recombinant activated factor VII is beneficial in severe factor VII deficiency. To understand why prophylactic treatment with both products is efficacious, we conducted a pharmacokinetic study. Ten factor VII deficient patients were treated with either recombinant activated (20 μg/kg) or plasma-derived (25 IU/kg) factor VII in a cross-over design. Pharmacokinetic parameters were analyzed through activated factor VII activity, factor VII clotting activity, and factor VII antigen levels on depicted time points. Factor VII activity half-lifes, determined by non-compartmental and one-compartmental analysis (results in brackets), were shorter for recombinant activated (1.4h; 0.7h) than for plasma-derived factor VII (6.8h; 3.2h); both recombinant activated (5.1h; 2.1h and plasma-derived factor VII (5.8h; 3.2h) resulted in longer half-lives of factor VII antigen. Activated factor VII half-lives (based on activated factor VII activity levels) were significantly higher compared to factor VII clotting activity (1.6h; 0.9h). Volumes of distribution were significantly higher for activated factor VII (236 ml/kg; 175 ml/kg, measured by activated factor VII) as compared to plasma-derived factor VII (206 ml/kg; 64 ml/kg, measured by factor FVII activity), suggesting a plasma- and extracellular fluid distribution for recombinant activated factor VII. Recombinant activated factor VII showed significantly shorter half-lifes than plasma-derived factor VII. Volumes of distribution were significantly higher for treatment with recombinant activated factor VII. The longer half-life for plasma-derived factor VII, compared to recombinant activated factor VII, and the increased volume of distribution for recombinant activated factor VII, compared to plasma-derived factor VII may further elucidate the beneficial effect of prophylactic treatment of both products. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. The short half-life descendents from radon measured in Sao Jose dos Campos and Cachoeira Paulista, Brazil, and its correlation with meteorological data

    International Nuclear Information System (INIS)

    Andrade Marinho, E.V. de.

    1985-09-01

    The correlations between the activity of the short half-life radon decay products in the low atmosphere and the meterological parameters, measuring the atmospheric polonium 214 are studied. The aerosols were collected on membrane filters and analysed by alpha spectrometry. Measurements have been made in Sao Jose dos Campos and Cachoeira Paulista, in Brazil. At S. Jose dos Campos the influence of the pluviometry on the concentration of atmospheric Po 214 has been analysed, showing that high activity correspond to low pluviometry and inversely, low activities correspond to high pluviometry. At Cachoeira Paulista, the variation in the atmospheric Po 214 activity in corresation with the air stability, measured, showing the accumulation of radioactive aerosols during the greater stability in the the lower atmospheric layers, was studied. (author) [pt

  15. Half-life measurement of 89Rb

    International Nuclear Information System (INIS)

    Guo Xiaoqing; Yuan Daqing; Xu Lijun; Chen Kesheng; Wu Yongle; Zheng Yanming; Yao Shunhe

    2013-01-01

    89 Rb is an important fission product used for monitoring possible release of fission products from fuel element. The half-life is one of important nuclear parameters. The half-life of 89 Rb was determined using reference source method with two sets of HPGe detectors by place-relay way. In reference source method, the ratio of net full- energy peak areas from the measure nuclide and the reference source was used to avoid the count correction caused by dead time and pileup. For the very short half-life of 89 Rb, the half-life iterative method was used in data analysis and the translation method was used in data unification. Finally, the measured half-life of 89 Rb is (14.41±0.04) min. (authors)

  16. Investigation concerning the relative formation rate and half-life time of short-lived nuclides with a fast conveyor tube system

    International Nuclear Information System (INIS)

    Kreiner, H.J.

    1976-01-01

    Since the installation of the 'Ultrafast Rabbit System' at the FRN in end of 1974, some research was started concerning the possibility of neutron activation analysis of short-lived nuclides (0.02 1/2 < 1 s) and measurements of short-lived fission products of U-235 and Pu-239. One of the results of the investigations is a more exact gamma-energy determination of the 0.8 s Cl-38m with 671.33 keV. In NAA it was possible to reach a sensitivity for lead and boron near 2 μg per sample respectively 10 ppm. In measurements of light fission products 0.1 - 8s after a pulse irradiation some differences of the relative formation rate and half-life in the region of A approximately 100 were found in comparison to literature. For example a strong build-up could be seen measuring the gamma-energy of 276.1 keV that belongs to Nb-101. Therefore we suppose the existence of an isomeric state of Nb-101. In comparison to our own results of yield ratio of the Pu- and U-fission products a good agreement with known data was found. Furthermore the measuring method gives the possibility of coordination of unknown gamma-lines to nuclides using the rate of formation, the half-life, the yield ratio between U and Pu and the build-up factor. That could be verified in some cases, e.g. Nb-103 and Sr-96. (author)

  17. Anti-restenotic effect of copper-62 liquid-filled balloon in porcine coronary arteries: novel use of a short half-life positron emitter

    International Nuclear Information System (INIS)

    Chan, Rosanna C.; Lacy, Jeffrey L.; Bhargava, Balram; Collins, Sara D.; Cates, Pamela; Cottin, Yves; Kollum, Marc; Yang, Nathan; Haynes, Neal G.; Martin, Christopher S.; Nayak, Nisha; Vodovotz, Yoram; Kim, Han-Soo; Waksman, Ron

    2000-01-01

    Purpose: To determine the efficacy of the use of copper-62, a positron emitter with a half-life of 9.7 minutes, as an intracoronary brachytherapy (IRBT) source in the prevention of neointima formation (NF) following overstretch balloon injury (BI) in the porcine model. Methods and Materials: Sixteen swine were treated after BI to their left anterior descending (LAD), left circumflex (LCX), and/or right coronary artery (RCA). Twelve of the injured arteries received placebo and 10 received 25 Gy, delivered to 0.5 mm from the surface of the treatment balloon filled with liquid 62 Cu. Dosimetry was based on Monte Carlo calculations. Two weeks after treatment, the animals were sacrificed, and the treated coronaries were perfusion-fixed and stained. Intimal area (IA) and medial fracture length (FL) were analyzed by computer-aided histomorphometry. Results: The ( 62 Zn/ 62 Cu) generator, together with a rapid concentration process, was successful in delivering the short-lived 62 Cu at the high concentration required for intravascular brachytherapy (IVBT). The fracture length in the two groups was similar (2.10 ± 0.57; 2.02 ± 0.77; p = NS). Arteries studied showed significant reduction in NF (IA: 0.23 ± 0.47 mm 2 vs. 1.08 ± 0.57 mm 2 ; p 62 Cu as an IVBT source is safe and feasible. All 16 swine tolerated the treatment well with no radiation-induced side effects or symptoms throughout the 2-week period. The isotope delivered the dose necessary to inhibit NF in the porcine coronary BI model

  18. Prediction of clearance, volume of distribution and half-life by allometric scaling and by use of plasma concentrations predicted from pharmacokinetic constants: a comparative study.

    Science.gov (United States)

    Mahmood, I

    1999-08-01

    Pharmacokinetic parameters (clearance, CL, volume of distribution in the central compartment, VdC, and elimination half-life, t1/2beta) predicted by an empirical allometric approach have been compared with parameters predicted from plasma concentrations calculated by use of the pharmacokinetic constants A, B, alpha and beta, where A and B are the intercepts on the Y axis of the plot of plasma concentration against time and alpha and beta are the rate constants, both pairs of constants being for the distribution and elimination phases, respectively. The pharmacokinetic parameters of cefpiramide, actisomide, troglitazone, procaterol, moxalactam and ciprofloxacin were scaled from animal data obtained from the literature. Three methods were used to generate plots for the prediction of clearance in man: dependence of clearance on body weight (simple allometric equation); dependence of the product of clearance and maximum life-span potential (MLP) on body weight; and dependence of the product of clearance and brain weight on body weight. Plasma concentrations of the drugs were predicted in man by use of A, B, alpha and beta obtained from animal data. The predicted plasma concentrations were then used to calculate CL, VdC and t1/2beta. The pharmacokinetic parameters predicted by use of both approaches were compared with measured values. The results indicate that simple allometry did not predict clearance satisfactorily for actisomide, troglitazone, procaterol and ciprofloxacin. Use of MLP or the product of clearance and brain weight improved the prediction of clearance for these four drugs. Except for troglitazone, VdC and t1/2beta predicted for man by use of the allometric approach were comparable with measured values for the drugs studied. CL, VdC and t1/2beta predicted by use of pharmacokinetic constants were comparable with values predicted by simple allometry. Thus, if simple allometry failed to predict clearance of a drug, so did the pharmacokinetic constant

  19. Half-life determination for 27Mg

    Science.gov (United States)

    Zahn, G. S.; Genezini, F. A.

    2015-07-01

    In this work, the half-life of the short-lived magnesium radionuclide 27Mg was measured by following the activity of samples after they were irradiated in the IEA-R1 reactor. An exponential decay function was then fitted to the results using the counts from a 60Co source as livetime chronometer; the individual half-life values obtained for each irradiation were compiled using both the usual unweighted and σ-2-weighted averages, as well as the robust averages obtained using the Normalized Residuals and the Rajeval techniques. The final halflive values obtained aren't compatible with the ENSDF compilation values, but have a similar uncertainty; analysis of the experimental literature values, all from the 50’s-60’s, show that further measurements should be undertaken in order to achieve a more robust consensus value for this half-life.

  20. Study of niobium isotopes having excess neutrons and a short half-life; Etude des isotopes du niobium excedentaires en neutrons et de courte periode

    Energy Technology Data Exchange (ETDEWEB)

    Huebenthal, K [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1968-02-01

    By irradiating Mo with 14 MeV neutrons isomers have been found for {sup 98}Nb (2.8 s half-life) {sup 99}Nb (9 s) and {sup 100}Nb (2.4 s). No isomer of this type seems to exist for {sup 96}Nb. Rapid separation methods are developed for isolating {sup 98}Zr from fission products, and for separating Zr and Nb. The half-life of {sup 98}Zr is measured (31 s) and the formation of {sup 98}Nb (2.8 s) from {sup 98}Zr (31 s) is shown by milking. Rough {beta} and {gamma} measurements of these nuclei are described. The {gamma} spectrum of {sup 98}Nb (51 mn) is studied with a high-resolution Ge/Li - detector. (authors) [French] Des irradiations des isotopes de molybdene avec des neutrons de 14 MeV ont mis en evidence l'existence des isomeres de {sup 98}Nb (periode 2.8 s) {sup 99}Nb (9 s) et {sup 100}Nb (2.4 s). Pour le {sup 96}Nb un isomere de ce type ne semble pas exister. Des methodes rapides de separation sont mises au point pour isoler le zirconium 98 des produits de fission, et pour separer ensuite le niobium du zirconium. La periode du {sup 98}Zr est de 3l s, et on demontre la formation du {sup 98}Nb (2.8 s) a partir du Zr (31 s). Ces corps sont etudies sommairement en spectroscopie {beta} et {gamma}. Le spectre gamma de {sup 98}Nb (periode 51 mn) est etudie avec un detecteur Ge/Li de haute resolution. (auteurs)

  1. Study of radioactive nuclides of very short half-life produced by fast neutrons; Etude de corps radioactifs a vie tres breve produits par neutrons rapides

    Energy Technology Data Exchange (ETDEWEB)

    Monnand, E [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1965-07-01

    Several radionuclides, already known, with half-lives ranging from 5 10{sup -5} to 1 second were observed by pulsed irradiations of C - Mg - Al - Y - In - Tl - Pb - Bi with 14.3 MeV neutrons. These radionuclides are: {sup 12}B (20 {+-} 0.4 ms) - {sup 24m}Na (20 {+-} 0.6 ms) - {sup 88m1}Y (0.332 {+-} 0.012 ms) - {sup 88m2}Y (14.6 {+-} 0.4 ms) - {sup 114m}In (43.5 {+-} 2 ms) - {sup 202m}Tl (0.570 {+-} 0.010 ms) - {sup 204m}Tl (0.063 {+-} 0.002 ms) - {sup 205m}Pb (5.5 {+-}0.3 ms) - {sup 206m}Pb (0.126 {+-} 0.006 ms) - {sup 207m}Pb (830 {+-} 30 ms) - {sup 208m}Bi (2.56 {+-} 0.1 ms). Their half-life, the {beta} and {gamma} rays energies and the production cross sections were measured. (author) [French] Plusieurs radionucleides deja connus, de periode comprise entre 5 10{sup -5} et 1 seconde ont ete observes par irradiation pulsee avec des neutrons de 14,3 MeV, des elements suivants: C - Mg - Al - Y - In - Tl - Pb - Bi. Ces radionucleides sont: {sup 12}B (20 {+-} 0.4 ms) - {sup 24m}Na (20 {+-} 0.6 ms) - {sup 88m1}Y (0.332 {+-} 0.012 ms) - {sup 88m2}Y (14.6 {+-} 0.4 ms) - {sup 114m}In (43.5 {+-} 2 ms) - {sup 202m}Tl (0.570 {+-} 0.010 ms) - {sup 204m}Tl (0.063 {+-} 0.002 ms) - {sup 205m}Pb (5.5 {+-}0.3 ms) - {sup 206m}Pb (0.126 {+-} 0.006 ms) - {sup 207m}Pb (830 {+-} 30 ms) - {sup 208m}Bi (2.56 {+-} 0.1 ms). Leur periode, l'energie des rayonnements {beta} et {gamma} emis, et la section efficace de production ont ete mesurees. (auteur)

  2. Positive serum specific IgE has a short half-life in patients with penicillin allergy and reversal does not always indicate tolerance.

    Science.gov (United States)

    Hjortlund, Janni; Mortz, Charlotte Gotthard; Stage, Tore Bjerregaard; Skov, Per Stahl; Dahl, Ronald; Bindslev-Jensen, Carsten

    2014-01-01

    The positive and negative predictive values of specific IgE to penicillins are not well established for penicillin hypersensitivity. One reason may be that serum IgE levels to penicillin diminish over time. The objective in this study was to investigate variations in serum half-life (T½) for specific IgE to penicillins (s-IgE) and to evaluate the outcome of penicillin challenges in patients with previous but not present specific IgE to penicillins. Two subgroups were investigated. All included patients had a history of penicillin allergy with reported symptoms such as urticaria/angioedema or unclassified cutaneous rash. T½ of specific IgE to penicillins was calculated based on sera from 29 patients with repeated measurements of s-IgE. Twenty-two patients with a previous positive s-IgE was followed and challenged with penicillin when IgE had become negative. The T½ for s-IgE varied between the 26 patients with decreasing s-IgE from 1.6 months to 76.4 months and 52% had a T½ of less than a year. The three patients with stable and increasing IgE-values showed T½ approaching infinity A total of 29 challenges with β-lactams were performed. Four different patterns were seen when evaluating the clinical reaction to challenge (positive/negative) and post-challenge boost of s-IgE (yes/no). Eight (36.4%) had negative challenge and negative post-challenge s-IgE, eight (36.4%) negative challenge, but positive post-challenge s-IgE levels. 3 (13.6%) had positive challenge and positive post-challenge s-IgE whereas 3 (13.6%) were challenge positive, but had negative post-challenge s-IgE. Specific IgE to penicillins declines over time stressing the importance of a close time relation between diagnostic work-up and clinical reaction. Reversal of previously positive s-IgE may still be associated with positive penicillin challenges and/or re-boostering of s-IgE to positivity.

  3. Fission rates measured using high-energy gamma-rays from short half-life fission products in fresh and spent nuclear fuel

    International Nuclear Information System (INIS)

    Kroehnert, H.

    2011-02-01

    In recent years, higher discharge burn-ups and initial fuel enrichments have led to more and more heterogeneous core configurations in light water reactors (LWRs), especially at the beginning of cycle when fresh fuel assemblies are loaded next to highly burnt ones. As this trend is expected to continue in the future, the Paul Scherrer Institute has, in collaboration with the Swiss Association of Nuclear Utilities, swissnuclear, launched the experimental programme LIFE(at)PROTEUS. The LIFE(at)PROTEUS programme aims to better characterise interfaces between burnt and fresh UO 2 fuel assemblies in modern LWRs. Thereby, a novel experimental database is to be made available for enabling the validation of neutronics calculations of strongly heterogeneous LWR core configurations. During the programme, mixed fresh and highly burnt UO 2 fuel lattices will be investigated in the zero-power research reactor PROTEUS. One of the main types of investigations will be to irradiate the fuel in PROTEUS and measure the resulting fission rate distributions across the interface between fresh and burnt fuel zones. The measurement of fission rates in burnt fuel re-irradiated in a zero-power reactor requires, however, the development of new experimental techniques which are able to discriminate against the high intrinsic activity of the fuel. The principal goal of the present research work has been to develop such a new measurement technique. The selected approach is based on the detection of high-energy gamma-ray lines above the intrinsic background (i.e. above 2200 keV), which are emitted by short-lived fission products freshly created in the fuel. The fission products 88 Kr, 142 La, 138 Cs, 84 Br, 89 Rb, 95 Y, 90m Rb and 90 Rb, with half-lives between 2.6 min and 2.8 h, have been identified as potential candidates. During the present research work, the gamma-ray activity of short-lived fission products has, for the first time, been measured and quantitatively evaluated for re

  4. Fission rates measured using high-energy gamma-rays from short half-life fission products in fresh and spent nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Kroehnert, H.

    2011-02-15

    In recent years, higher discharge burn-ups and initial fuel enrichments have led to more and more heterogeneous core configurations in light water reactors (LWRs), especially at the beginning of cycle when fresh fuel assemblies are loaded next to highly burnt ones. As this trend is expected to continue in the future, the Paul Scherrer Institute has, in collaboration with the Swiss Association of Nuclear Utilities, swissnuclear, launched the experimental programme LIFE(at)PROTEUS. The LIFE(at)PROTEUS programme aims to better characterise interfaces between burnt and fresh UO{sub 2} fuel assemblies in modern LWRs. Thereby, a novel experimental database is to be made available for enabling the validation of neutronics calculations of strongly heterogeneous LWR core configurations. During the programme, mixed fresh and highly burnt UO{sub 2} fuel lattices will be investigated in the zero-power research reactor PROTEUS. One of the main types of investigations will be to irradiate the fuel in PROTEUS and measure the resulting fission rate distributions across the interface between fresh and burnt fuel zones. The measurement of fission rates in burnt fuel re-irradiated in a zero-power reactor requires, however, the development of new experimental techniques which are able to discriminate against the high intrinsic activity of the fuel. The principal goal of the present research work has been to develop such a new measurement technique. The selected approach is based on the detection of high-energy gamma-ray lines above the intrinsic background (i.e. above 2200 keV), which are emitted by short-lived fission products freshly created in the fuel. The fission products {sup 88}Kr, {sup 142}La, {sup 138}Cs, {sup 84}Br, {sup 89}Rb, {sup 95}Y, {sup 90m}Rb and {sup 90}Rb, with half-lives between 2.6 min and 2.8 h, have been identified as potential candidates. During the present research work, the gamma-ray activity of short-lived fission products has, for the first time, been

  5. Methodical Challenges and a Possible Resolution in the Assessment of Receptor Reserve for Adenosine, an Agonist with Short Half-Life

    Directory of Open Access Journals (Sweden)

    Judit Zsuga

    2017-05-01

    Full Text Available The term receptor reserve, first introduced and used in the traditional receptor theory, is an integrative measure of response-inducing ability of the interaction between an agonist and a receptor system (consisting of a receptor and its downstream signaling. The underlying phenomenon, i.e., stimulation of a submaximal fraction of receptors can apparently elicit the maximal effect (in certain cases, provides an opportunity to assess the receptor reserve. However, determining receptor reserve is challenging for agonists with short half-lives, such as adenosine. Although adenosine metabolism can be inhibited several ways (in order to prevent the rapid elimination of adenosine administered to construct concentration–effect (E/c curves for the determination, the consequent accumulation of endogenous adenosine biases the results. To address this problem, we previously proposed a method, by means of which this bias can be mathematically corrected (utilizing a traditional receptor theory-independent approach. In the present investigation, we have offered in silico validation of this method by simulating E/c curves with the use of the operational model of agonism and then by evaluating them using our method. We have found that our method is suitable to reliably assess the receptor reserve for adenosine in our recently published experimental setting, suggesting that it may be capable for a qualitative determination of receptor reserve for rapidly eliminating agonists in general. In addition, we have disclosed a possible interference between FSCPX (8-cyclopentyl-N3-[3-(4-(fluorosulfonylbenzoyloxypropyl]-N1-propylxanthine, an irreversible A1 adenosine receptor antagonist, and NBTI (S-(2-hydroxy-5-nitrobenzyl-6-thioinosine, a nucleoside transport inhibitor, i.e., FSCPX may blunt the effect of NBTI.

  6. Increased volume of distribution for recombinant activated factor VII and longer plasma-derived factor VII half-life may explain their long lasting prophylactic effect

    NARCIS (Netherlands)

    Mathijssen, N.C.J.; Masereeuw, R.; Holme, P.A.; Kraaij, M.G.J. van; Laros, B.A.P.; Peyvandi, F.; Heerde, W.L. van

    2013-01-01

    INTRODUCTION: Prophylaxis with plasma-derived or recombinant activated factor VII is beneficial in severe factor VII deficiency. To understand why prophylactic treatment with both products is efficacious, we conducted a pharmacokinetic study. MATERIALS AND METHODS: Ten factor VII deficient patients

  7. A simplified radioimmunoassay for melatonin and its application to biological fluids. Preliminary observations on the half-life of plasma melatonin in man

    International Nuclear Information System (INIS)

    Wetterberg, L.; Friberg, Y.; Eriksson, O.; Vangbo, B.

    1978-01-01

    A simplified and rapid radioimmunoassay (RIA) for melatonin is presented. Melatonin is extracted from serum, plasma or urine and RIA is performed by using [ 3 H]melatonin as the tracers. The standard curve covers the range 0.2-4.3 nmol/l. By increasing the sample volume the range can be extended to 0.06 nmol/l. The intra-assay variability is 7% (relative standard deviation=rsd) and the inter-assay variability is 10% (rsd). The recovery of melatonin added to calf serum is 96%. The long term variability of the assay (43 assays on aliquots of one serum sample during 6 months) is 13.5% (rsd). The serum levels in man after one oral dose of 430 μmol melatonin have been measured. The peak value, 620 nmol/l, was noted after 0.5 h and the melatonin concentration was still above the normal range at 24 h (2.1 nmol/l). (Auth.)

  8. Half-life of 230Th

    International Nuclear Information System (INIS)

    Meadows, J.W.; Armani, R.J.; Callis, E.L.; Essling, A.M.

    1980-01-01

    The half-life of 230 Th was measured by the specific activity method. Alpha counting was done in a low geometry counter whose geometry factor was calculated from its dimensions. Sample weights were determined by isotopic dilution. Measurements were made on four isotopic mixtures ranging from 0.383 to 99.52% 230 Th. The half-life is 75381 +- 295 years

  9. On the biological half-life of caesium in pregnant women and infants

    International Nuclear Information System (INIS)

    Rundo, J.; Turner, F.M.

    1992-01-01

    In the 1960s, changes were observed in the levels of 137 Cs in women who were pregnant or who had recently given birth. These were not associated with changes in the rate of fall-out, and were interpreted as the consequences of changes in the biological half-life. It was deduced that the biological half-life of caesium just before parturition averaged 59% of the value (87±33 days) after the birth of the baby; and that there was a step change at parturition. The behaviour of the levels during pregnancy suggested there was a gradual decrease in the biological half-life. Similar measurements were made in very young children. The concentration of the radionuclide in a breast-fed baby was usually a little less than that in the mother, indicating some discrimination in the transfer from plasma to milk; the concentration in a bottle-fed baby increased substantially and rapidly from the level at or shortly after birth. Data for three babies were sufficiently extensive to permit determination of the biological half-life in each. Values of 8.7±0.6 days, 15.4±1.1 days, and 14.9±3.6 days were derived. (author)

  10. Safety objectives and basic design for surface centres for long-term storage of solid radioactive waste with short or medium half-life and low or medium specific activity

    International Nuclear Information System (INIS)

    1984-06-01

    RFS or Regles Fondamentales de Surete (Basic Safety Rules) applicable to certain types of nuclear facilities lay down requirements with which compliance, for the type of facilities and within the scope of application covered by the RFS, is considered to be equivalent to compliance with technical French regulatory practice. The object of the RFS is to take advantage of standardization in the field of safety, while allowing for technical progress in that field. They are designed to enable the operating utility and contractors to know the rules pertaining to various subjects which are considered to be acceptable by the Service Central de Surete des Installations Nucleaires, or the SCSIN (Central Department for the Safety of Nuclear Facilities). These RFS should make safety analysis easier and lead to better understanding between experts and individuals concerned with the problems of nuclear safety. The SCSIN reserves the right to modify, when considered necessary, any RFS and specify, if need be, the terms under which a modification is deemed retroactive. The role of this RFS is to define the safety objectives and the basic design philosophy for surface centres for long-term storage of packages of radioactive waste with short or medium half-life and with low or medium specific activity

  11. Half-life determination of 125I

    International Nuclear Information System (INIS)

    De Felice, P.; Ientile, P.; Zicari, C.

    1990-01-01

    The half-life of 125 I was determined by measuring the activity of an initial 3 kBq source at several times. Over a period of two months, 96 absolute measurements were performed, using the sum-peak method to give a half-life of (59.38±0.03) d. A discussion is presented on the effect of correcting for accidental coincidences on the half-life measurements by comparing the results with and without this correction. (orig.)

  12. Half Life Measurements in 155Gd

    International Nuclear Information System (INIS)

    Malmskog, S.G.

    1966-08-01

    In the literature there exists a definite difference for the half life of the 86.5 keV level in Gd depending on whether 155 Eu or 155 Tb sources have been used. Using a good energy resolution electron-electron coincidence spectrometer and a 155 Eu source, a half life of 6.48 ± 0.26 nsec was obtained for the 86.5 keV level. This is in agreement with the values previously measured with 155 Tb sources. The half life of the 105.4 keV level was measured to be 1.12 ± 0.05 nsec

  13. Half Life Measurements in {sup 155}Gd

    Energy Technology Data Exchange (ETDEWEB)

    Malmskog, S G

    1966-08-15

    In the literature there exists a definite difference for the half life of the 86.5 keV level in Gd depending on whether {sup 155}Eu or {sup 155}Tb sources have been used. Using a good energy resolution electron-electron coincidence spectrometer and a {sup 155}Eu source, a half life of 6.48 {+-} 0.26 nsec was obtained for the 86.5 keV level. This is in agreement with the values previously measured with {sup 155}Tb sources. The half life of the 105.4 keV level was measured to be 1.12 {+-} 0.05 nsec.

  14. 243Cm half-life determinaton

    International Nuclear Information System (INIS)

    Timofeev, G.A.; Kalygin, V.V.; Privalova, P.A.

    1986-01-01

    By molar ratios of 243 Cm mixture with 244 Cm and Pu nuclides formed as a result of Cm nuclides α-decay the 243 Cm half-life T α243 is determined. The 244 Cm half-life is measured earlier with high accuracy. The 243 Cm/ 244 Cm ratio measured by means of a mass spectrometer equals 0.989+-0.004. The obtained value T α243 =29.20+-0.14 years

  15. Experimental half-life determination of 176Lu

    International Nuclear Information System (INIS)

    Kossert, Karsten; Jörg, Gerhard; Gostomski, Christoph Lierse v.

    2013-01-01

    The half-life of the naturally occurring long-lived rare earth isotope 176 Lu was determined by a combination of highly sophisticated experimental procedures in order to further improve the reliability and the precision of literature data. The amount of lutetium in the samples was determined by inductively coupled plasma optical emission spectrometry (ICP-OES) using a NIST reference standard. The isotopic ratio N( 176 Lu)/N(Lu) in the samples was measured by means of inductively coupled plasma high resolution mass spectrometry (ICP-HRMS). The activity divided by the mass of Lu was determined by applying liquid scintillation (LS) counting. The LS counting efficiency of the beta/gamma emitter 176 Lu was determined with the CIEMAT/NIST efficiency tracing technique with low uncertainty. The influences of colour quenching and background effects are discussed in this paper. The half-life was found to be 3.640(35)×10 10 y. The result is in good agreement with other evaluations and the relative standard uncertainty of 0.95% is among the lowest of previously published data. - Highlights: • The half-life of 176 Lu was determined by ICP-OES, ICP-HRMS and LSC. • The LSC efficiency was determined with the CIEMAT/NIST method. • The half-life was found to be 3.640(35)×10 10 y

  16. Half-life of 51Mn

    Science.gov (United States)

    Graves, Stephen A.; Ellison, Paul A.; Valdovinos, Hector F.; Barnhart, Todd E.; Nickles, Robert J.; Engle, Jonathan W.

    2017-07-01

    The half-life of 51Mn was measured by serial gamma spectrometry of the 511-keV annihilation photon following decay by β+ emission. Data were collected every 100 seconds for 100,000-230,000 seconds within each measurement (n =4 ). The 511-keV incidence rate was calculated from the 511-keV spectral peak area and count duration, corrected for detector dead time and radioactive decay. Least-squares regression analysis was used to determine the half-life of 51Mn while accounting for the presence of background contaminants, notably 55Co. The result was 45.59 ±0.07 min, which is the highest precision measurement to date and disagrees with the current Nuclear Data Sheets value by over 6 σ .

  17. Half-life of samarium-147

    CERN Document Server

    Kinoshita, N; Nakanishi, T

    2003-01-01

    The alpha-decay half-life of sup 1 sup 4 sup 7 Sm has been reevaluated. Known amounts of natural Sm and an alpha-emitter standard ( sup 2 sup 1 sup 0 Po, sup 2 sup 3 sup 8 U, or sup 2 sup 4 sup 1 Am) were mixed well to prepare thin sources for the simultaneous counting of sup 1 sup 4 sup 7 Sm and the alpha-emitter standard by means of an alpha-spectrometer using a silicon surface barrier detector. The alpha-disintegration rate of known amounts of sup 1 sup 4 sup 7 Sm was determined by reference to the alpha activity of the standard. The source preparation and counting were repeated to establish the reproducibility of the present half-life determination, and supplementary alpha spectrometry was carried out by a liquid-scintillation spectrometer. The arithmetic mean of the experimental half-life values was obtained to be (1.17 +- 0.02) x 10 sup 1 sup 1 y. This value is about 10% longer than the currently adopted value, (1.06 +- 0.02) x 10 sup 1 sup 1 y, and the possible factors for this difference are discussed...

  18. The half-life of 125I

    International Nuclear Information System (INIS)

    Simpson, B.R.S.; Meyer, B.R.

    1989-01-01

    The Bureau International des Poids et Mesures (BIPM) organized an international comparison of activity measurements of a solution of 125 I. The half-life value adopted was 59.5±0.4d. The large uncertainty took account of a recently published value (Schrader, 1986) which is considerably lower than the widely used value of 60.0±0.1d. The present work, which was undertaken at the suggestion of the BIPM, has yielded a value which confirms the lower measurement. (author)

  19. Half-life of Xe120

    Science.gov (United States)

    Phillips, A. A.; Andreoiu, C.; Ball, G. C.; Bandyopadhyay, D.; Behr, J. A.; Chupp, T. E.; Finlay, P.; Garrett, P. E.; Grinyer, G. F.; Hackman, G.; Hayden, M. E.; Hyland, B.; Nuss-Warren, S. R.; Pearson, M. R.; Schumaker, M. A.; Smith, M. B.; Svensson, C. E.; Tardiff, E. R.; Valiente-Dobón, J. J.; Warner, T.

    2006-08-01

    We have measured the half-life of Xe120 using a high-purity germanium (HPGe) detector to monitor the 176, 178, and 762 keV γ rays from Xe120 β+ decay. The result, 46±0.6 min, differs significantly from the value 40±1 min reported by Andersson [Ark. Fys. 28, 37 (1964)]. We have also measured the half-lives of Cs120 and I120 to be 60±0.7 s and 82.1±0.6 min, respectively, both of which are consistent with previous measurements.

  20. Glucagon-like Peptide 1 Conjugated to Recombinant Human Serum Albumin Variants with Modified Neonatal Fc Receptor Binding Properties. Impact on Molecular Structure and Half-Life

    DEFF Research Database (Denmark)

    Bukrinski, Jens T.; Sønderby, Pernille; Antunes, Filipa

    2017-01-01

    Glucagon-like peptide 1 (GLP-1) is a small incretin hormone stimulated by food intake, resulting in an amplification of the insulin response. Though interesting as a drug candidate for the treatment of type 2 diabetes mellitus, its short plasma half-life of less than 3 minutes limits its clinical...... use. A strategy to extend the half-life of GLP-1 utilizes the long half-life of human serum albumin (HSA) by combining the two via chemical conjugation or genetic fusion. HSA has a plasma half-life of around 21 days owing to its interaction with the neonatal Fc receptor (FcRn) expressed in endothelial...... with the available structural information on the FcRn and GLP-1 receptor (GLP-1R) obtained from X-ray crystallography, we can explain the observed in-vitro and in-vivo behaviour. We conclude that the conjugation of GLP-1 to rHSA does not affect the interaction between rHSA and FcRn, while the observed decrease...

  1. Immunological half-life of porcine proinsulin C-peptide

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, H; Horino, M; Matsumura, S [Kawasaki Medical Coll., Kurashiki (Japan). Div. of Endocrinology; Kobayshi, K; Suetsugu, N [Yamaguchi Univ., Ube (Japan). School of Medicine

    1975-11-01

    Immunological half-lifes of injected porcine C-peptide and insulin with RIA were studied and calculated as 9.8 and 8.0 minutes. Higher circulating levels of C-peptide as compared to insulin in normal young swines lead to speculation about a longer half-life of C-peptide. This hypothesis was verified in this study. Immunological half-lifes of porcine proinsulin and insulin in the pig were 20 and 6 minutes, respectively.

  2. Analytical studies by activation. Part A and B: Counting of short half-life radio-nuclides. Part C: Analytical programs for decay curves; Etudes d'analyse par activation. Parties A et B: le comptage des radio-nucleides de periodes courtes. Partie C: programme de depouillement des courbes de decroissance

    Energy Technology Data Exchange (ETDEWEB)

    Junod, E [Commissariat a l' Energie Atomique Grenoble (France). Centre d' Etudes Nucleaires

    1966-03-01

    Part A and B: Since a radio-nuclide of short half-life is characterized essentially by the decrease in its activity even while it is being measured, the report begins by recalling the basic relationships linking the half-life the counting time, the counting rate and the number of particles recorded. The second part is devoted to the problem of corrections for counting losses due to the idle period of multichannel analyzers. Exact correction formulae have been drawn up for the case where the short half-life radionuclide is pure or contains only a long half-life radio-nuclide. By comparison, charts have been drawn up showing the approximations given by the so-called 'active time' counting and by the counting involving the real time associated with a measurement of the overall idle period, this latter method proving to be more valid than the former. A method is given for reducing the case of a complex mixture to that of a two-component mixture. Part C: The problems connected with the qualitative and quantitative analysis of the decay curves of a mixture of radioactive sources of which one at least has a short half-life are presented. A mathematical description is given of six basic processes for which some elements of Fortran programs are proposed. Two supplementary programs are drawn up for giving an overall treatment of problems of dosage in activation analysis: one on the basis of a simultaneous irradiation of the sample and of one or several known samples, the other with separate irradiation of the unknown and known samples, a dosimeter (activation, or external) being used for normalizing the irradiation flux conditions. (author) [French] Parties A et B: Un radionucleide de periode courte etant defini specialement par la decroissance de son activite pendant la duree meme du comptage, on rappelle en premiere partie de ce rapport les relations fondamentales qui lient periode, temps de comptage, taux de comptage et nombre d'impulsions enregistrees. La seconde partie

  3. Experimental study of half-life determinations using 60Co

    International Nuclear Information System (INIS)

    Rutledge, A.R.; Smith, L.V.; Merritt, J.S.

    1983-01-01

    The half-life of 60 Co was determined by two methods, (i) the 4π#betta# ionization chamber method and (ii) the 4π #betta#-#betta# coincidence method. The first is a relative counting method in which the only rate-dependent correction is for background, whereas the second is an 'absolute' counting method which involves several rate-dependent corrections. In addition, various methods of calculation of the results were tested. The half-life values for the two counting systems were in good agreement and the weighted mean value for the half-life of 60 Co was found to be 1925.02+-0.47 d. (orig.)

  4. Tests of a Fast Plastic Scintillator for High-Precision Half-Life Measurements

    Science.gov (United States)

    Laffoley, A. T.; Dunlop, R.; Finlay, P.; Leach, K. G.; Michetti-Wilson, J.; Rand, E. T.; Svensson, C. E.; Grinyer, G. F.; Thomas, J. C.; Ball, G.; Garnsworthy, A. B.; Hackman, G.; Orce, J. N.; Triambak, S.; Williams, S. J.; Andreoiu, C.; Cross, D.

    2013-03-01

    A fast plastic scintillator detector is evaluated for possible use in an ongoing program of high-precision half-life measurements of short lived β emitters. Using data taken at TRI-UMF's Isotope Separator and Accelerator Facility with a radioactive 26Na beam, a detailed investigation of potential systematic effects with this new detector setup is being performed. The technique will then be applied to other β-decay half-life measurements including the superallowed Fermi β emitters 10C, 14O, and T = 1/2 decay of 15O.

  5. A new determination of the 209Po half-life

    International Nuclear Information System (INIS)

    Collé, R; Fitzgerald, R P; Laureano–Perez, L

    2014-01-01

    A substantial 25% error in the then-known and accepted (102 ± 5) year half-life of 209 Po was reported on in 2007. This error was detected from decay data from two separate primary standardizations of a 209 Po solution standard, which were performed approximately 12 years apart. Despite author claims that this observation was not a new half-life determination, it was nevertheless included in subsequent nuclear data evaluations and compilations to obtain a currently tabulated value of (115 ± 13) a, computed from the median and range of the two half-life reports. A third primary standardization on the identical 209 Po solution has since been performed to derive a new half-life value of (125.2 ± 3.3) a. This half-life determination was obtained from 30 distinct data sets over a period of 20.7 years, encompassing over 700 liquid scintillation measurements with nearly 50 counting sources all prepared from the same solution, and as obtained over a very broad range of measurement conditions (composition of cocktails, characteristics of counters, time sequencing) during five periods in 1993, 1994, 2005, and 2013. (paper)

  6. Half-life of 90Sr - measurement and critical review

    International Nuclear Information System (INIS)

    Woods, M.J.; Lucas, S.E.M.

    1996-01-01

    Recent evaluations of the half-life of 90 Sr have demonstrated the variable quality of the available experimental data which has prevented the estimation and adoption of a value that commands confidence. In an attempt to reduce the uncertainty in the half-life to an acceptable level, the decay of a 90 Sr source has been followed for over six years at NPL. The equipment comprised matching, re-entrant, high-pressure ionization chambers and a long-lived reference source to reduce non-random effects. The experimental technique is described together with the statistical procedure used to analyse the measured data. A half-life value was determined together with an estimate of the associated uncertainties. A new evaluation of the 90 Sr half-life has been made, taking account of the new NPL data and other recent measurements. Particular attention has been paid to the experimental techniques used to produce the data and the uncertainties attributed to them. An objective evaluation has been conducted to produce a new recommended half-life value of 10 516 ± 21 days. (orig.)

  7. Dual Constant Domain-Fab: A novel strategy to improve half-life and potency of a Met therapeutic antibody.

    Science.gov (United States)

    Cignetto, Simona; Modica, Chiara; Chiriaco, Cristina; Fontani, Lara; Milla, Paola; Michieli, Paolo; Comoglio, Paolo M; Vigna, Elisa

    2016-06-01

    The kinase receptor encoded by the Met oncogene is a sensible target for cancer therapy. The chimeric monovalent Fab fragment of the DN30 monoclonal antibody (MvDN30) has an odd mechanism of action, based on cell surface removal of Met via activation of specific plasma membrane proteases. However, the short half-life of the Fab, due to its low molecular weight, is a severe limitation for the deployment in therapy. This issue was addressed by increasing the Fab molecular weight above the glomerular filtration threshold through the duplication of the constant domains, in tandem (DCD-1) or reciprocally swapped (DCD-2). The two newly engineered molecules showed biochemical properties comparable to the original MvDN30 in vitro, acting as full Met antagonists, impairing Met phosphorylation and activation of downstream signaling pathways. As a consequence, Met-mediated biological responses were inhibited, including anchorage-dependent and -independent cell growth. In vivo DCD-1 and DCD-2 showed a pharmacokinetic profile significantly improved over the original MvDN30, doubling the circulating half-life and reducing the clearance. In pre-clinical models of cancer, generated by injection of tumor cells or implant of patient-derived samples, systemic administration of the engineered molecules inhibited the growth of Met-addicted tumors. Copyright © 2016 Federation of European Biochemical Societies. Published by Elsevier B.V. All rights reserved.

  8. Development of controller of acquisition and sample positioner for activation for use in measurements of short half-life radioisotopes; Desenvolvimento de dispositivo movimentador automatizado de amostras com vista a aplicacao em medidas de radioisotopos que possuem curto tempo de meia-vida

    Energy Technology Data Exchange (ETDEWEB)

    Secco, Marcello

    2016-08-01

    High resolution gamma spectroscopy measurements have several applications. Those involving short half-life radioisotope measurements may present low precision problems when the radioactive source is far from detector end cup and in the very high activity situations also can present accuracy loss due to dead time and pile-up effects. A way to overcome these problems is changing the source detector distance as the activity is decreasing, and thereby maximizing the statistical counting. In the present study, the Controller of Acquisition and Sample Positioner for Activation (CASPA) was developed. It is a low cost and weight device, made with low atomic number materials designed to assist gamma spectroscopy measurements, which is able to control the distance between the source and the detector, even allowing that there is a change of this distance during the measurement process. Because it is automated it optimizes the time of the operator, who has complete freedom to program their routine measurements in the device besides minimizing the radiation dose in the operator. An interface that allow the user control the CASPA system and to program the acquisition system was created. Tests aiming to optimize the operation of CASPA system were carried out and the safety of the CASPA operation was verified, it was not presented any failure during their tests. It was applied the repeatability tests by the acquisition {sup 60}Co standard source and was found that the positioning of automated system has reproduced the results of static system with a 95% of confidence level. (author)

  9. Determination of the {sup 151}Sm half-life

    Energy Technology Data Exchange (ETDEWEB)

    Be, Marie-Martine; Cassette, Philippe [CEA, LIST, Gif sur Yvette (France). LNE-Laboratoire National Henri Becquerel; Isnard, Helene [CEA-LANIE, Gif sur Yvette (France); and others

    2015-07-01

    New measurements have been undertaken to determine the half-life of {sup 151}Sm. A pure {sup 151}Sm solution was obtained after chemical separation from a samarium solution resulting from the dissolution of an irradiated samarium sample. The concentration of {sup 151}Sm in the solution was measured by mass spectrometry, combined with the isotope dilution technique. The activity of the solution was measured by liquid scintillation counting by six European laboratories as part of an international comparison. These combined results lead to a half-life of T{sub 1/2} = 94.6(6)a.

  10. Calculation of the biological half-life of radioactive isotopes

    International Nuclear Information System (INIS)

    Szabo, S.A.

    1982-01-01

    The biological half-life of 137 Cs and 90 Sr was determined based on K and Ca metabolism and on the considerable chemical similarity of K and Ca, carriers of Cs and Sr, resp. The tsub(1/2)=a/bxln2 formula was used for the calculation, where a is the quantity of the element in question, while b is the daily need of the animal for the given element. The biological half-life for cattle of both 137 Cs and 90 Sr was found to be 30 days, while that for swine 20 days and 35 days respectively. (Sz.J.)

  11. Measurement of the 20F half-life

    Science.gov (United States)

    Hughes, M.; George, E. A.; Naviliat-Cuncic, O.; Voytas, P. A.; Chandavar, S.; Gade, A.; Huyan, X.; Liddick, S. N.; Minamisono, K.; Paulauskas, S. V.; Weisshaar, D.

    2018-05-01

    The half-life of the 20F ground state was measured using a radioactive beam implanted in a plastic scintillator and recording β γ coincidences together with four CsI(Na) detectors. The result, T1 /2=11.0011 (69) stat(30) sys s, is at variance by 17 combined standard deviations with the two most precise results. The present value revives the poor consistency of results for this half-life and calls for a new measurement, with a technique having different sources of systematic effects, to clarify the discrepancy.

  12. Half-life distribution table of radioactive nuclei

    International Nuclear Information System (INIS)

    Gugenberger, P.

    1954-01-01

    This table allows to identify an element if its period is known. Data for this table were taken from the half-life values adopted by Hollander, PERLMAN and SEABORG (Rev. mod. Phys., 1953, 22 number 2). Moreover for each nucleus, the mass number, the charge number and the type of decay are given in the table. (author) [fr

  13. Determination of disintegration half-life of 252Cf

    International Nuclear Information System (INIS)

    Chen Keliang; Liu Guoxing; Wang Sufang; Zheng Jiwen

    1991-01-01

    The follow-up measurements have been made by using a Si(Au) detector with small solid angle geometry for α disintegration of 252 Cf. The measured half-life of disintegration is 2.638 ± 0.009 year. This value is in accordance with other previous results

  14. Beyond effective half-life characterization of radionuclide dynamics

    International Nuclear Information System (INIS)

    Hermanska, J.; Blazek, T.; Karny, M.

    1996-01-01

    A refined model was set up and tested of the effective radionuclide half-life in nuclear medicine, making allowance for the fact that the basic assumption that the observed data can be fitted by a mono-exponential, as well as some other assumptions, is not true. The results are discussed. (P.A.). 1 tab., 32 refs

  15. Half-life of the superallowed β+ emitter Ne18

    Science.gov (United States)

    Grinyer, G. F.; Smith, M. B.; Andreoiu, C.; Andreyev, A. N.; Ball, G. C.; Bricault, P.; Chakrawarthy, R. S.; Daoud, J. J.; Finlay, P.; Garrett, P. E.; Hackman, G.; Hyland, B.; Leslie, J. R.; Morton, A. C.; Pearson, C. J.; Phillips, A. A.; Schumaker, M. A.; Svensson, C. E.; Valiente-Dobón, J. J.; Williams, S. J.; Zganjar, E. F.

    2007-08-01

    The half-life of Ne18 has been determined by detecting 1042-keV γ rays in the daughter F18 following the superallowed-Fermi β+ decay of samples implanted at the center of the 8πγ-ray spectrometer, a spherical array of 20 HPGe detectors. Radioactive Ne18 beams were produced on-line, mass-separated, and ionized using an electron-cyclotron-resonance ionization source at the ISAC facility at TRIUMF in Vancouver, Canada. This is the first high-precision half-life measurement of a superallowed Fermi β decay to utilize both a large-scale HPGe spectrometer and the isotope separation on-line technique. The half-life of Ne18, 1.6656 ± 0.0019 s, deduced following a 1.4σ correction for detector pulse pile-up, is four times more precise than the previous world average. As part of an investigation into potential systematic effects, the half-life of the heavier isotope Ne23 was determined to be 37.11 ± 0.06 s, a factor of 2 improvement over the previous precision.

  16. Measurement of the 8Li half-life

    International Nuclear Information System (INIS)

    Flechard, X.; Lienard, E.; Naviliat-Cuncic, O.; Ban, G.; Carniol, B.; Etasse, D.; Fontbonne, J. M.; Rodriguez, D.; Lallena, A. M.; Alvarez, M. A. G.; Praena, J.

    2010-01-01

    We report a new measurement of the 8 Li half-life using a plastic scintillator and an ultrafast waveform digitizing module. The result, T 1/2 =(838.40±0.36) ms, improves by a factor of 2.5 the most precise result obtained so far and is furthermore deduced with negligible corrections due to dead time.

  17. Radioactive source simulation for half-life experiment

    International Nuclear Information System (INIS)

    Wanitsuksombut, Warapon; Decthyothin, Chanti

    1999-01-01

    A simulation of radioactivity decay by using programmable light source with a few minutes half-life is suggested. A photodiode with digital meter label in cps is use instead of radiation detector. Both light source and photodiode are installed in a black box to avoid surrounding room light. The simulation set can also demonstrate Inverse Square Law experiment of radiation penetration. (author)

  18. Measurement of the 230U half-life

    International Nuclear Information System (INIS)

    Pommé, S.; Altzitzoglou, T.; Van Ammel, R.; Suliman, G.; Marouli, M.; Jobbágy, V.; Paepen, J.; Stroh, H.; Apostolidis, C.; Abbas, K.; Morgenstern, A.

    2012-01-01

    The 230 U half-life was determined by measuring the decay curve of 230 U sources by various nuclear detection techniques: α-particle counting at a defined small solid angle; 4πα+β counting with a windowless CsI sandwich spectrometer, a liquid scintillation counter and a pressurised proportional counter; gamma-ray spectrometry with a HPGe detector and nearly-2π α-particle counting with an ion-implanted silicon detector. Depending on the technique, the decay was followed for 100–200 d, which is 5–10 times the 230 U half-life. The measurement results of the various techniques were in good mutual agreement. The mean value, T 1/2 ( 230 U)=20.23 (2) d, is lower than the literature value which is based on one measurement in 1948 and resulted in a half-life value of 20.8 d without statement of uncertainty. A correction for the ingrowth of the long-lived 210 Pb and its daughter products may have been overlooked in the past. - Highlights: ► Half-life of 230 U determined by various nuclear detection techniques. ► Result T 1/2 ( 230 U)=20.23 (2) d is lower than the literature value. ► 230 U/ 226 Th decay series has potential use in alpha-immunotherapy.

  19. Determination of {sup 126}Sn half-life from ICP-MS and gamma spectrometry measurements

    Energy Technology Data Exchange (ETDEWEB)

    Bienvenu, P.; Arnal, N.; Comte, J. [CEA Cadarache DEN/DEC/SA3C/LARC, Paul Lez Durance (France); Ferreux, L.; Lepy, M.C.; Be, M.M. [CEA Saclay LIST LNE/LNHB, Gif sur Yvette (France); Andreoletti, G. [AREVA Cogema SL/UP2-800, Beaumont Hague (France)

    2009-07-01

    A new value of {sup 126}Sn half-life was determined by combination of inductively coupled plasma-mass spectrometry (ICP-MS) and gamma spectrometry measurements on purified sample solutions collected from nuclear fuel reprocessing. {sup 126}Sn was isolated through dissolution of fission product precipitates and liquid-liquid extraction with N-benzoyl-N-phenyl-hydroxylamine (BPHA). The abundance of {sup 126}Sn atoms together with the absence of interfering species in the analysed solutions made it possible to measure both mass concentration and nuclide activity with high precision and accuracy. This led to a {sup 126}Sn half-life value of 1.980 (57) x 10{sup 5} a. (orig.)

  20. A novel exendin-4 human serum albumin fusion protein, E2HSA, with an extended half-life and good glucoregulatory effect in healthy rhesus monkeys

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Ling; Wang, Lin; Meng, Zhiyun; Gan, Hui; Gu, Ruolan; Wu, Zhuona; Gao, Lei; Zhu, Xiaoxia; Sun, Wenzhong; Li, Jian; Zheng, Ying; Dou, Guifang, E-mail: douguifang@vip.163.com

    2014-03-07

    Highlights: • E2HSA has an extended half-life and good plasma stability. • E2HSA could improve glucose-dependent insulin secretion. • E2HSA has excellent glucoregulatory effects in vivo. • E2HSA could potentially be used as a new long-acting GLP-1 receptor agonist for type 2 diabetes management. - Abstract: Glucagon-like peptide-1 (GLP-1) has attracted considerable research interest in terms of the treatment of type 2 diabetes due to their multiple glucoregulatory functions. However, the short half-life, rapid inactivation by dipeptidyl peptidase-IV (DPP-IV) and excretion, limits the therapeutic potential of the native incretin hormone. Therefore, efforts are being made to develop the long-acting incretin mimetics via modifying its structure. Here we report a novel recombinant exendin-4 human serum albumin fusion protein E2HSA with HSA molecule extends their circulatory half-life in vivo while still retaining exendin-4 biological activity and therapeutic properties. In vitro comparisons of E2HSA and exendin-4 showed similar insulinotropic activity on rat pancreatic islets and GLP-1R-dependent biological activity on RIN-m5F cells, although E2HSA was less potent than exendin-4. E2HSA had a terminal elimation half-life of approximate 54 h in healthy rhesus monkeys. Furthermore, E2HSA could reduce postprandial glucose excursion and control fasting glucose level, dose-dependent suppress food intake. Improvement in glucose-dependent insulin secretion and control serum glucose excursions were observed during hyperglycemic clamp test (18 h) and oral glucose tolerance test (42 h) respectively. Thus the improved physiological characterization of E2HSA make it a new potent anti-diabetic drug for type 2 diabetes therapy.

  1. Measurement of the half-life of 68Ga

    International Nuclear Information System (INIS)

    García-Toraño, Eduardo; Peyrés Medina, Virginia; Romero, Eduardo; Roteta, Miguel

    2014-01-01

    The half-life of the positron-emitter 68 Ga has been measured by following the decay rate with two systems based on ionization chamber and Ge detectors. The decay rate was measured for periods of time up to 10 half-lives. The combination of the 6 results obtained with both systems gives a value of T 1/2 =67.845(18) min, in good agreement with recommended data and with an uncertainty lower than any other previously reported value. - Highlights: • The half-life of the positron-emitter radionuclide 68 Ga was measured. • Two measurement setups (ionization chamber and Ge detector) were used. • Results agree with evaluated data but exhibit lower uncertainty

  2. Superior serum half life of albumin tagged TNF ligands

    International Nuclear Information System (INIS)

    Mueller, Nicole; Schneider, Britta; Pfizenmaier, Klaus; Wajant, Harald

    2010-01-01

    Due to their immune stimulating and apoptosis inducing properties, ligands of the TNF family attract increasing interest as therapeutic proteins. A general limitation of in vivo applications of recombinant soluble TNF ligands is their notoriously rapid clearance from circulation. To improve the serum half life of the TNF family members TNF, TWEAK and TRAIL, we genetically fused soluble variants of these molecules to human serum albumin (HSA). The serum albumin-TNF ligand fusion proteins were found to be of similar bioactivity as the corresponding HSA-less counterparts. Upon intravenous injection (i.v.), serum half life of HSA-TNF ligand fusion proteins, as determined by ELISA, was around 15 h as compared to approximately 1 h for all of the recombinant control TNF ligands without HSA domain. Moreover, serum samples collected 6 or 24 h after i.v. injection still contained high TNF ligand bioactivity, demonstrating that there is only limited degradation/inactivation of circulating HSA-TNF ligand fusion proteins in vivo. In a xenotransplantation model, significantly less of the HSA-TRAIL fusion protein compared to the respective control TRAIL protein was required to achieve inhibition of tumor growth indicating that the increased half life of HSA-TNF ligand fusion proteins translates into better therapeutic action in vivo. In conclusion, our data suggest that genetic fusion to serum albumin is a powerful and generally applicable mean to improve bioavailability and in vivo activity of TNF ligands.

  3. Half-life predictions for decay modes of superheavy nuclei

    International Nuclear Information System (INIS)

    Duarte, S.B.; Tavares, O.A.P.; Goncalves, M.; Rodriguez, O.; Guzman, F.; Barbosa, T.N.; Garcia, F.; Dimarco, A.

    2004-09-01

    We applied the Effective Liquid Drop Model (ELDM) to predict the alpha-decay, cluster emission and cold fission half-life-values of nuclei in the region of Superheavy Elements (SHE). The present calculations have been made in the region of the ZN-plane defined by 155 <=N <=220 and 110<=Z<=135. Shell effects are included via the Q-value of the corresponding decay case. We report the results of a systematic calculation of the half-life for the three nuclear decay modes in a region of the ZN-plane where superheavy elements are expected to be found. Results have shown that, among the decay modes investigated here, the alpha decay is the dominant one. i.e, the decay mode of smallest half-lives. Half-life predictions for alpha decay, cluster emission and cold fission for the isotopic family of the most recent SHE detected of Z=115 and for the isotopic family of the already consolidated SHE of Z=111 are presented. (author)

  4. Beryllium-10: Half-life and AMS-standards

    International Nuclear Information System (INIS)

    Hofmann, H.J.; Beer, J.; Bonani, G.; von Gunten, H.R.; Raman, S.; Suter, M.; Walker, R.L.; Woelfli, W.; Zimmermann, D.

    1987-01-01

    Absolute AMS measurements of 10 Be require reliable standards for calibration. Among the existing standards, rather large differences have been observed. These differences were found partially to be due to the different half-life values which were assumed. Also for comparison of AMS data with activity measurements, it is necessary to know the 10 Be half-life as precisely as possible. Starting with 5 ml of the standardized ORNL-MASTER solution, a working solution with a well-defined 10 Be content was prepared. Its specific activity was determined by liquid scintillation counting. This measurement yielded a new value of (1.52 +- 0.05) My for the 10 Be half-life, which is in agreement with the previously reported values but is about three times more accurate. Two independent dilution series produced new AMS standards with 10 Be/ 9 Be ratios of the order of 10 -10 and 10 -11 . These standards were measured at the ETH/SIN AMS facility with high accuracy and are compared with other available 10 Be standards. 15 refs, 2 figs., 3 tabs

  5. Calculation of chemical elimination half-life from blood with an ongoing exposure source: the example of perfluorooctanoic acid (PFOA).

    Science.gov (United States)

    Russell, Mark H; Waterland, Robert L; Wong, Fiona

    2015-06-01

    Determination of the chemical clearance rate from human blood is a critical component of toxicokinetic exposure assessment. Analysis of temporal biomonitoring data without consideration of ongoing exposure results in calculation of apparent elimination half-life values that are longer than the intrinsic value. The intrinsic elimination half-life is solely a function of the rate of elimination while the apparent elimination half-life reflects the processes of both elimination and ongoing exposure. Confusion between intrinsic and apparent half-life values can lead to misinterpretation of biomonitoring data and can result in exaggerated predictions in subsequent modeling efforts. This work provides a review of the first-order equations that have been developed to calculate intrinsic and apparent half-life values and the potential bias that can result from confusing these two values. Published human biomonitoring data for perfluorooctanoic acid (PFOA) are analyzed using these equations to provide examples of low, medium and high bias in determination of the intrinsic elimination half-life from plasma or serum, the components of blood typically analyzed for PFOA. An approach is also provided to estimate the extent of exposure reduction that is indicated by declining longitudinal or cross-sectional biomonitoring data. Based on the evaluation methodology presented in this work, the intrinsic elimination half-life of PFOA in humans is 2.4years, representing the average of independent estimates of 2.5years (95% CI, 2.4-2.7) and 2.3years (95% CI, 2.1-2.4). The declining concentration of PFOA in blood of the general USA adult population represents an estimated exposure reduction of 20-30% over the period 1999-2008. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Precision half-life measurement of 17F

    Science.gov (United States)

    Brodeur, M.; Nicoloff, C.; Ahn, T.; Allen, J.; Bardayan, D. W.; Becchetti, F. D.; Gupta, Y. K.; Hall, M. R.; Hall, O.; Hu, J.; Kelly, J. M.; Kolata, J. J.; Long, J.; O'Malley, P.; Schultz, B. E.

    2016-02-01

    Background: The precise determination of f t values for superallowed mixed transitions between mirror nuclide are gaining attention as they could provide an avenue to test the theoretical corrections used to extract the Vu d matrix element from superallowed pure Fermi transitions. The 17F decay is particularly interesting as it proceeds completely to the ground state of 17O, removing the need for branching ratio measurements. The dominant uncertainty on the f t value of the 17F mirror transition stems from a number of conflicting half-life measurements. Purpose: A precision half-life measurement of 17F was performed and compared to previous results. Methods: The life-time was determined from the β counting of implanted 17F on a Ta foil that was removed from the beam for counting. The 17F beam was produced by transfers reaction and separated by the TwinSol facility of the Nuclear Science Laboratory of the University of Notre Dame. Results: The measured value of t1/2 new=64.402 (42) s is in agreement with several past measurements and represents one of the most precise measurements to date. In anticipation of future measurements of the correlation parameters for the decay and using the new world average t1/2 world=64.398 (61) s, we present a new estimate of the mixing ratio ρ for the mixed transition as well as the correlation parameters based on assuming Standard Model validity. Conclusions: The relative uncertainty on the new world average for the half-life is dominated by the large χ2=31 of the existing measurements. More precision measurements with different systematics are needed to remedy to the situation.

  7. Dependence of radiocaesium biological half-life in freshwater fish on water potassium concentration and temperature

    International Nuclear Information System (INIS)

    Carreiro, M.C.V.; Corisco, J.A.G.

    1998-01-01

    Short-term experiments (35-49 days) showed that the rate of cesium elimination from fish increases with increasing potassium concentration in water (the biological half-life decreases); this, however, is only true of the potassium concentration range of 0.35 to 3.5 ppm, whereas higher potassium concentrations do not seem to affect the elimination rate. Decrease in water temperature within the 20 degC to 5 degC range slows down the cesium elimination process. (P.A.)

  8. Comparison of isotope dilution and excretion methods for determining the half-life of ascorbic acid in the guinea pig

    International Nuclear Information System (INIS)

    Kipp, D.E.; Rivers, J.M.

    1984-01-01

    The half-life of ascorbic acid (AA) in guinea pigs was investigated by the isotope dilution and excretion methods. The dilution method measures [1-14C]AA disappearance from the plasma, whereas the excretion method measures the elimination of [1-14C]AA and the metabolites from the body. Two groups of animals underwent both isotope studies in reverse order. Animals were conditioned to the experimental procedures and fed 2.5 mg AA/100 g body weight orally to maintain a daily intake of the vitamin independent of food consumption. The two isotope procedures imposed similar stress on the animals, as determined by plasma cortisol levels and body weight changes. The AA half-life calculations of the rapidly exchangeable pool by the isotope dilution method yielded values of 1.23 and 0.34 hours for the two groups, respectively. The half-life of the slowly exchangeable pool for the two groups was 60.2 and 65.8 hours, respectively. The half-life of AA in the rapidly exchangeable pool, as measured by the excretion studies, was 4.57-8.75 hours. For the slowly exchangeable pool, it was 146-149 hours. The longer half-life of both pools obtained with the excretion method indicates that the isotope is disappearing from the plasma more rapidly than it is being excreted. This suggests that a portion of the [1-14C]AA leaving the plasma is removed to a body pool that is not sampled by the isotope excretion method

  9. Short wavelength striations on expanding plasma clouds

    International Nuclear Information System (INIS)

    Winske, D.; Gary, S.P.

    1989-01-01

    The growth and evolution of short wavelength (< ion gyroradius) flute modes on a plasma expanding across an ambient magnetic field have been actively studied in recent years, both by means of experiments in the laboratory as well as in space and through numerical simulations. We review the relevant observations and simulations results, discuss the instability mechanism and related linear theory, and describe recent work to bring experiments and theory into better agreement. 30 refs., 6 figs

  10. Fenobody: A Ferritin-Displayed Nanobody with High Apparent Affinity and Half-Life Extension.

    Science.gov (United States)

    Fan, Kelong; Jiang, Bing; Guan, Zhe; He, Jiuyang; Yang, Dongling; Xie, Ni; Nie, Guohui; Xie, Can; Yan, Xiyun

    2018-04-10

    Nanobodies consist of a single domain variable fragment of a camelid heavy-chain antibody. Nanobodies have potential applications in biomedical fields because of their simple production procedures and low cost. Occasionally, nanobody clones of interest exhibit low affinities for their target antigens, which, together with their short half-life limit bioanalytical or therapeutic applications. Here, we developed a novel platform we named fenobody, in which a nanobody developed against H5N1 virus is displayed on the surface of ferritin in the form of a 24mer. We constructed a fenobody by substituting the fifth helix of ferritin with the nanobody. TEM analysis showed that nanobodies were displayed on the surface of ferritin in the form of 6 × 4 bundles, and that these clustered nanobodies are flexible for antigen binding in spatial structure. Comparing fenobodies with conventional nanobodies currently used revealed that the antigen binding apparent affinity of anti-H5N1 fenobody was dramatically increased (∼360-fold). Crucially, their half-life extension in a murine model was 10-fold longer than anti-H5N1 nanobody. In addition, we found that our fenobodies are highly expressed in Escherichia coli, and are both soluble and thermo-stable nanocages that self-assemble as 24-polymers. In conclusion, our results demonstrate that fenobodies have unique advantages over currently available systems for apparent affinity enhancement and half-life extension of nanobodies. Our fenobody system presents a suitable platform for various large-scale biotechnological processes and should greatly facilitate the application of nanobody technology in these areas.

  11. Thyroid fractional deposition and half life of radioiodine

    International Nuclear Information System (INIS)

    Fujita, Minoru

    1974-01-01

    In order to measure the absorbed dose of radioiodine in the thyroid gland, which was incorporated by halation or ingestion, iodine intake (fa), 131 I thyroid uptake rate(fw), 131 I thyroid uptake rate compared to the rate in the whole body (f 2 ) and the half life of iodine in the thyroid gland(Teff) were examined. Thyroid fractional deposition of 131 I was compared between Japanese and European. The rate of 131 I which moved from the blood into the thyroid gland in children (f 2 ') and the effect of the iodine in meals on 131 I thyroid uptake (fw) were also studied. In Japanese, f 2 was 0.28 and the mean Teff was 6.9 +- 0.7 days in 11 Japanese adults. There was an individual difference in these biological parameter and the values in adults were different from those in children. A little difference in value between Japanese and European suggested to be caused by the greater amount of stable iodine in meals in Japanese. (Serizawa, K.)

  12. A formula for half-life of proton radioactivity

    Science.gov (United States)

    Zhang, Zhi-Xing; Dong, Jian-Min

    2018-01-01

    We present a formula for proton radioactivity half-lives of spherical proton emitters with the inclusion of the spectroscopic factor. The coefficients in the formula are calibrated with the available experimental data. As an input to calculate the half-life, the spectroscopic factor that characterizes the important information on nuclear structure should be obtained with a nuclear many-body approach. This formula is found to work quite well, and in better agreement with experimental measurements than other theoretical models. Therefore, it can be used as a powerful tool in the investigation of proton emission, in particular for experimentalists. Supported by National Natural Science Foundation of China (11435014, 11405223, 11675265, 11575112), the 973 Program of China (2013CB834401, 2013CB834405), National Key Program for S&T Research and Development (2016YFA0400501), the Knowledge Innovation Project (KJCX2-EW-N01) of Chinese Academy of Sciences, the Funds for Creative Research Groups of China (11321064) and the Youth Innovation Promotion Association of Chinese Academy of Sciences

  13. On the way to high-power linear proton accelerator for the long half-life radionuclides transmutation

    International Nuclear Information System (INIS)

    Batskikh, G.I.; Lupandin, O.S.; Murin, B.P.; Fedotov, A.P.

    1991-01-01

    The concept of continuous mode high-power linear proton accelerator with 1.5 GeV energy, 0.3 A current for the long half-life nuclides transmutation into the short ones (waste of atomic power plants (APP)) is proposed. The accelerator design main principles, scheme and parameters are presented. The accent is made on the accelerator efficiency, reliability and radiation purity. (author)

  14. Accurate γ-ray spectrometry measurements of the half-life of 92Sr

    International Nuclear Information System (INIS)

    Leconte, P.; Hudelot, J.P.; Antony, M.

    2008-01-01

    Studies of the nuclear fuel cycle require an accurate knowledge of the energy release from the decay of radioactive nuclides produced in a reactor, including precise half-life data for the short-lived radionuclides. Moreover, short-lived fission products are crucial for fission rate distribution measurements performed in low-power facilities, such as EOLE and MINERVE of CEA Cadarache [Fougeras, P., 2005. EOLE, MINERVE and MASURCA facilities and their associated neutron experimental programs. In: 13th International Conference on Nuclear Engineering, Beijing, China, 16-20 May 2005], and their nuclear decay data need to be known to high precision. For these reasons, the half-life of 92 Sr has been measured to solve a recently observed inconsistency identified with the quoted value in the main nuclear applications libraries (including JEFF3.1): T 1/2 =2.71±0.01 h [Parsa, B., Ashari, A., Goolvard, L., Nobar, Y.M., 1971. Decay scheme of 2.71 h 92 Sr. Nucl. Phys. A 175, 629-640]. An overestimation of 4.5% has been identified in this work, based on two independent methods. Specific γ-ray spectrometry measurements on activated fissile foils have been carried out, using two HPGe detectors. Influencing factors such as net area measurements of photopeaks, pulse pile-up accuracy and dead time corrections in the presence of decaying activity are discussed. A new value has been obtained by combining eight series of measurements: T 1/2 =2.594±0.006 h. The uncertainty has been reduced by a factor of two with respect to previous evaluations. This measured value also shows good agreement with the most recent studies of T 1/2 =2.627±0.009 h [Nir-El, Y., 2003. Private Communications. Soreq Research Centre, Yavne, Israel

  15. Precise half-life measurement of the superallowed emitter 30S

    Science.gov (United States)

    Iacob, V. E.; Hardy, J. C.; Chen, L.; Horvat, V.; Bencomo, M.; Nica, N.; Park, H. I.; Roeder, B. T.; Saastamoinen, A.

    2018-03-01

    We have measured the half-life of 30S, the parent of a superallowed 0+→0+β transition, to a high precision using very pure sources and a 4 π proportional gas counter to detect the decay positrons. Our result for the half-life is 1.179 92(34) s. As a by-product of this measurement, we determine the half-life of its daughter, 30P, to be 2.501(2) min.

  16. On the 209Po half-life error and its confirmation. A critique

    International Nuclear Information System (INIS)

    Colle, R.; Colle, A.M.

    2016-01-01

    A recent report on 209 Po claimed to have made a determination of the 125-a half-life from measurements made over 0.8 % of one half-life. A careful reanalysis of the original data with a more complete and rigorous consideration of the underlying uncertainties demonstrates that this claim cannot withstand critical scrutiny. More importantly, this critique examines the larger issue as to what constitutes a valid half-life determination, and highlights that a careful and realistic analysis beyond the mere fitting of decay data to an exponential function is required for the measurement and reporting of half-life values. (author)

  17. The ecological half-life of 137Cs in undisturbed silt soil

    International Nuclear Information System (INIS)

    Drosg, M.

    2012-01-01

    The time necessary to safely cultivate agricultural areas after they have been contaminated by radioactivity (e.g. after the Chernobyl accident) is not determined by the physical half-life of the radioactive isotopes in question but by their (usually much shorter) ecological half-life (). This half-life not only depends on the type of soil but also on whether the soil was fertilized or not. Therefore it is not possible to determine an ecological half-life that is universally valid. However, the value for undisturbed, unfertilized soil should provide a general indication for the duration of ecological half-life. In a silt soil in Vienna, Austria, the ecological half-life of 137 Cs was determined to be 0.8 years, which is much shorter than the physical half-life of 30 years. - Highlights: ► Absolute measurements of 137 Cs radioactivity in leaves of perennial plants. ► The natural 40 K radioactivity served as reference. ► The ecological half-life of 137 Cs in loamy soil was determined.

  18. Absorption and biological half-life in humans of intrinsic and extrinsic 54Mn tracers from foods of plant origin

    International Nuclear Information System (INIS)

    Johnson, P.E.; Lykken, G.I.; Korynta, E.D.

    1991-01-01

    Absorption and biological half-life of 54 Mn were measured in adult men and women fed foods labeled intrinsically or extrinsically with 54 Mn. Each subject consumed a series of three test meals consisting of a food labeled intrinsically, a food labeled extrinsically or MnCl 2 (control) served in random order. The foods tested were lettuce, spinach, wheat and sunflower seeds. Lettuce meals and their controls contained 9.65 mumol Mn; other meals contained 22.50 mumol Mn. In addition to the test food or MnCl 2 , each meal consisted of vegetable oil (5 g), salt (NaCl, 0.15 g) and crackers (10 g), which provided 0.55 mumol Mn. There were no differences in percentage of Mn absorption or biological half-life of 54 Mn for any of the intrinsically/extrinsically labeled food pairs. Absorption of 54 Mn from MnCl 2 (8.90%) was greater than from lettuce (5.20%), spinach (3.81%), wheat (2.16%) or sunflower seeds (1.71%), but the biological half-life did not vary with the source of Mn. Absorption of 54 Mn from lettuce was significantly (P less than 0.05) greater than from wheat or sunflower seeds. Although the Mn dose in the test meal was less for lettuce than for the other foods, there was no difference in Mn absorption from MnCl 2 between the subjects fed lettuce and subjects fed other foods. There was no correlation of either 54 Mn absorption or biological half-life with whole blood or plasma Mn

  19. The half-life of 227Th by direct and indirect measurements

    International Nuclear Information System (INIS)

    Collins, S.M.; Pommé, S.; Jerome, S.M.; Ferreira, K.M.; Regan, P.H.; Pearce, A.K.

    2015-01-01

    Utilising a chemically purified solution the radioactive half-life of 227 Th has been determined indirectly by observation of the ingrowth of 223 Ra using an ionisation chamber (IC) and for the first time by direct observation of the change in activity with time using a high-purity germanium (HPGe) γ-ray spectrometer. The radioactive decay was observed for ~104 days (~5.6 half-lives) by γ-ray spectrometry and approximately 63 days and 72 days (~3.4 and ~3.9 half-lives) using an ionisation chamber (IC). The resulting half-life values – 18.695 (4) days (IC) and 18.683 (20) days (HPGe) – are consistent and detailed uncertainty budgets are presented for the two measurement techniques. A weighted mean of our results of 18.695 (4) days is inconsistent with the most precise published half-life value of 18.7176 (52) days (Jordan and Blanke, 1967). A critical evaluation of literature data has been performed, indicating a paucity of reliable and independent measurements. Selected independent published values have been used to determine a recommended half-life of 18.697 (7) days. A method has been introduced in the course of this work so that the recommended half-life of 227 Th as determined by ingrowth can be modified if a different 223 Ra half-life has been determined, evaluated and adopted. - Highlights: • First direct measurement of 227 Th half-life by HPGe γ-ray spectrometry. • Precision half-life measurement by ionisation chamber. • New half-life of 18.695 (4) days determined. • Critical evaluation of published half-lives and recommended value determined

  20. Half-life evaluations for 3H, 90Sr, and 90Y

    International Nuclear Information System (INIS)

    MacMahon, Desmond

    2006-01-01

    A recent paper has reviewed methods for the evaluation of discrepant sets of data and demonstrated the results of applying these methods to the published half-life data of 90 Sr and 137 Cs [MacMahon, T.D., Pearce, A., Harris, P., 2004. Convergence of techniques for the evaluation of discrepant data. Appl. Radiat. Isot. 60, 275-281]. The half-life data for 3 H has been subject to a comprehensive review and critical evaluation by Lucas and Unterweger [2000. Comprehensive review and critical evaluation of the half-life of tritium. J. Res. Natl. Inst. Stand. Technol. 105, 541-549]. The current paper reports the results of applying the various evaluation procedures of MacMahon et al. Convergence of techniques for the evaluation of discrepant data. Appl. Radiat. Isot. 60, 275-281] to the data of Lucas and Unterweger [Comprehensive review and critical evaluation of the half-life of tritium. J. Res. Natl. Inst. Stand. Technol. 105, 541-549], resulting in a recommended half-life of 4497(4) days. MacMahon et al. [Convergence of techniques for the evaluation of discrepant data. Appl. Radiat. Isot. 60, 275-281] highlighted problems in the evaluation of the discrepant half-life data of 90 Sr, in particular the worrying upward trend in the data, where the weighted mean of all the measurements increases, on average, by 35 days each time a new measurement result is added. The current paper reports on further analyses of these data. New measurements of the half-life of 90 Y have been reported by Kossert and Schrader [2004. Standardization by liquid scintillation counting and half-life measurements of 90 Y. Appl. Radiat. Isot. 60, 741]. This has prompted a new evaluation of all available published 90 Y half-life data. The data are fairly consistent, and a value of 64.063(16) h is recommended

  1. Update of NIST half-life results corrected for ionization chamber source-holder instability.

    Science.gov (United States)

    Unterweger, M P; Fitzgerald, R

    2014-05-01

    As reported at the ICRM 2011, it was discovered that the source holder used for calibrations in the NIST 4πγ ionization chamber (IC) was not stable. This has affected a large number of half-life measurement results previously reported and used in compilations of nuclear data. Corrections have been made on all of the half-life data based on the assumption that the changes to the ionization chamber response were gradual. The corrections are energy dependent and therefore radionuclide specific. This presentation will review our results and present the recommended changes in half-life values and/or uncertainties. © 2013 Published by Elsevier Ltd.

  2. Update of NIST half-life results corrected for ionization chamber source-holder instability

    International Nuclear Information System (INIS)

    Unterweger, M.P.; Fitzgerald, R.

    2014-01-01

    As reported at the ICRM 2011, it was discovered that the source holder used for calibrations in the NIST 4πγ ionization chamber (IC) was not stable. This has affected a large number of half-life measurement results previously reported and used in compilations of nuclear data. Corrections have been made on all of the half-life data based on the assumption that the changes to the ionization chamber response were gradual. The corrections are energy dependent and therefore radionuclide specific. This presentation will review our results and present the recommended changes in half-life values and/or uncertainties. - Highlights: • The NIST half-life data is corrected for sample positioning variations and refitted. • These results are reported and increased errors in the reported values are given. • Longer lived radionuclides are discussed

  3. Influence of sex and age on the biological half-life of cadmium in mice

    International Nuclear Information System (INIS)

    Taguchi, T.; Suzuki, S.

    1981-01-01

    The influence of age on the whole-body biological half-life of 109 Cd was studied in male mice following ip injection. The influence of sex on whole-body and organ retention was ascertained after sc injection. The whole-body biological half-life of 109 Cd of the older mice was more than twice that of the younger mice, and that of the female mice was longer than that of the males. These differences demonstrate a biological difference between males and females with respect to whole-body half-life of 109 Cd. The effects of age and sex on the biological half-life of Cd in mice are assessed quantitatively

  4. The HP 9825 A program for the determination of an isotope half-life

    International Nuclear Information System (INIS)

    Jujuratisbela, Uju.

    1980-01-01

    Determination of half life of gold 198, indium 116, manganese 56, copper 64 are presented, using least squares method in HP 9825 A. This method is more accurate and needs less time than graphic method. (author tr.)

  5. Designing of peptides with desired half-life in intestine-like environment

    KAUST Repository

    Sharma, Arun; Singla, Deepak; Rashid, Mamoon; Raghava, Gajendra Pal Singh

    2014-01-01

    hindered mainly because of their high susceptibility towards proteases degradation. We have developed an in silico method to predict the half-life of peptides in intestine-like environment and to design better peptides having optimized physicochemical

  6. Standardization of 40 K by liquid scintillation counting. Determination of the half-life

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    1997-01-01

    The relative abundance of the natural radioisotope ''40 K in environmental samples frequently generates interferences in low activity measurements. In the present study we propose the determination of ''40 K by the CIEMAT/NIST method. On this context, the verification of ''40 K half-life is required. We present a half-life value obtained by liquid scintillation counting in excellent agreement with those reported in the literature. (Author)

  7. Goiania radiation accident: 30 years - a half-life for a whole life..

    International Nuclear Information System (INIS)

    Reis, R.G.; Lucena, E.A.; Arantes, R.R.; Silva, A.A.; Reis, A.A.

    2017-01-01

    The radiological accident in Goiânia, Brazil, considered the largest urban radiological accident in the world, generated several publications in the technical area that are widely disseminated in the scientific literature, given the importance of the lessons learned. However, in a simple conversation with people who worked on that accident, it is noted that many reports have not been recorded. In this year in which 30 years of the event is completed, it will be of great value to record personal testimonies that are not in technical or scientific books. And what can we tell after a half-life that lasted for a lifetime? The lived stories, the situations, the improvisations, the way to solve, the overcoming, the human side, the emotions, happy or sad, short or long, funny or not. The objective of this work is to preserve, maintain and divulge reports and situations experienced by people who worked on the radiological accident with Cs-137 in Goiânia. Audio or video recordings about experiences lived in Goiânia by people who worked in that emergency situation were carried out. The reports are free and the form of registration is always at the discretion of the narrator. Storing records allows to preserve, maintain, and disclose the accident to other generations

  8. Short communication Relationship between sperm plasma ...

    African Journals Online (AJOL)

    Matshidiso MB. Masenya

    2017-01-04

    Jan 4, 2017 ... observed between sperm plasma membrane integrity and fertility. There was a weak positive correlation between normal sperm morphology and conception rate (r = 0.11). Additionally ..... been approved by all of us. Authors' ...

  9. Using gamma distribution to determine half-life of rotenone, applied in freshwater

    Energy Technology Data Exchange (ETDEWEB)

    Rohan, Maheswaran, E-mail: mrohan@aut.ac.nz [Department of Biostatistics and Epidemiology, Auckland University of Technology, Auckland (New Zealand); Fairweather, Alastair; Grainger, Natasha [Science and Capability, Department of Conservation, Hamilton (New Zealand)

    2015-09-15

    Following the use of rotenone to eradicate invasive pest fish, a dynamic first-order kinetic model is usually used to determine the half-life and rate at which rotenone dissipated from the treated waterbody. In this study, we investigate the use of a stochastic gamma model for determining the half-life and rate at which rotenone dissipates from waterbodies. The first-order kinetic and gamma models produced similar values for the half-life (4.45 days and 5.33 days respectively) and days to complete dissipation (51.2 days and 52.48 days respectively). However, the gamma model fitted the data better and was more flexible than the first-order kinetic model, allowing us to use covariates and to predict a possible range for the half-life of rotenone. These benefits are particularly important when examining the influence that different environmental factors have on rotenone dissipation and when trying to predict the rate at which rotenone will dissipate during future operations. We therefore recommend that in future the gamma distribution model is used when calculating the half-life of rotenone in preference to the dynamic first-order kinetics model. - Highlights: • We investigated the use of the gamma model to calculate the half-life of rotenone. • Physical and environmental variables can be incorporated into the model. • A method for calculating the range around a mean half-life is presented. • The model is more flexible than the traditionally used first-order kinetic model.

  10. Phenytoin shortens the half-life of the hypoxic cell radiosensitizer misonidazole in man: implications for possible reduced toxicity

    International Nuclear Information System (INIS)

    Workman, P.; Bleehen, N.M.; Wiltshire, C.R.; Cambridge Univ.

    1980-01-01

    Results are described of a preliminary study of the effects of phenytoin, (commonly used as an anticonvulsant in the treatment of patients with brain tumours), on the plasma pharmacokinetics of misonidazole (MISO) in man. Previous studies have shown that pretreatment with phenytoin shortens the half-life of MISO in dogs and mice by induction of drug metabolizing enzymes, and also reduces the acute lethal effects of MISO in mice. In this study patients with various types of malignancy and with cerebral metastases were given MISO before and after a course of phenytoin. Others were assessed as controls without phenytoin administration. Plasma concentrations of MISO were determined in blood samples taken before and at various times after administration. A summary of the pharmacokinetic data obtained is given. (author)

  11. Designing of peptides with desired half-life in intestine-like environment

    KAUST Repository

    Sharma, Arun

    2014-08-20

    Background: In past, a number of peptides have been reported to possess highly diverse properties ranging from cell penetrating, tumor homing, anticancer, anti-hypertensive, antiviral to antimicrobials. Owing to their excellent specificity, low-toxicity, rich chemical diversity and availability from natural sources, FDA has successfully approved a number of peptide-based drugs and several are in various stages of drug development. Though peptides are proven good drug candidates, their usage is still hindered mainly because of their high susceptibility towards proteases degradation. We have developed an in silico method to predict the half-life of peptides in intestine-like environment and to design better peptides having optimized physicochemical properties and half-life.Results: In this study, we have used 10mer (HL10) and 16mer (HL16) peptides dataset to develop prediction models for peptide half-life in intestine-like environment. First, SVM based models were developed on HL10 dataset which achieved maximum correlation R/R2 of 0.57/0.32, 0.68/0.46, and 0.69/0.47 using amino acid, dipeptide and tripeptide composition, respectively. Secondly, models developed on HL16 dataset showed maximum R/R2 of 0.91/0.82, 0.90/0.39, and 0.90/0.31 using amino acid, dipeptide and tripeptide composition, respectively. Furthermore, models that were developed on selected features, achieved a correlation (R) of 0.70 and 0.98 on HL10 and HL16 dataset, respectively. Preliminary analysis suggests the role of charged residue and amino acid size in peptide half-life/stability. Based on above models, we have developed a web server named HLP (Half Life Prediction), for predicting and designing peptides with desired half-life. The web server provides three facilities; i) half-life prediction, ii) physicochemical properties calculation and iii) designing mutant peptides.Conclusion: In summary, this study describes a web server \\'HLP\\' that has been developed for assisting scientific

  12. 18F half-life measurement using a high-purity germanium detector

    International Nuclear Information System (INIS)

    Han, Jubong; Lee, K.B.; Park, T.S.; Lee, J.M.; Oh, P.J.; Lee, S.H.; Kang, Y.S.; Ahn, J.K.

    2012-01-01

    The half-life of 18 F has been measured using HPGe detectors with a 137 Cs reference source. The counting ratio of 511 keV γ-rays from 18 F to 622 keV γ-rays from 137 Cs was fitted for the half-life with a weighted least-square method. Uncertainties due to the systematic effects arising from the measurement of a high activity 18 F source were studied in detail. The half-life of 18 F was found to be (109.72±0.19) min. The result is in a good agreement with the recommended value of (109.728±0.019) min evaluated at the Laborotaire National Henri Becquerel (LNHB). - Highlights: ► The 18 F half-life was measured with a reference source and without it using HPGe detectors. ► We found the systematic effect ‘activity dynamic range effect’ by monitoring the counts of the reference source. ► This activity dynamic range effect was corrected by using the reference source method. ► The 18 F half-life using the reference source method was in a good agreement with the recommended value of LNHB.

  13. The half-life of 207Bi and decays of 211At and 211Po

    International Nuclear Information System (INIS)

    Yanokura, M.; Kudo, H.; Nakahara, H.; Miyano, K.; Ohya, S.; Nitoh, O.

    1978-01-01

    The half-life of 207 Bi was obtained from the genetic relation between 207 Po and 207 Bi, and between 211 At and 207 Bi. The half-life was found to be 33.4 +- 0.8 y. The half-life of 207 Po was determined to be 5.81 +- 0.04 h by following the decay of the characteristic γ-rays from 207 Po. The half-life of 211 At was determined to be 7.23 +- 0.02 h by following the decay of γ-rays and α-particles from 211 At and 211 Po. The half-lives determined in the present work for 207 Po and 211 At agree with the literature although the half-life of 207 Bi differs considerably from the currently accepted value of 38 y. The branching ratio of 211 At decaying through EC and α-decay modes was determined together with the branching ratios of the three α-particles emitted from 211 Po. (Auth.)

  14. Re-measurement of the half-life of sup 7 sup 9 Se

    CERN Document Server

    Jiang Song Sheng; Diao Li Jun; Li Chun Shen; GouJingRu; Wu Shao Yon

    2002-01-01

    A new attempt has been made for the re-measurement of the half-life of sup 7 sup 9 Se. We made two major improvements over our earlier sup 7 sup 9 Se half-life determination (Nucl. Instr. and Meth. B 123 (1997) 403). Firstly, the half-life of sup 7 sup 9 Se was measured relative to the precisely known half-life of sup 7 sup 5 Se, rather than an absolute measurement of sup 7 sup 9 Se/Se. Secondly, the Projectile X-ray Detection technique was used for the separation of sup 7 sup 9 Se from its isobar, sup 7 sup 9 Br, rather than measuring sup 8 sup 1 Br for the deduction of sup 7 sup 9 Br interference, and this technique was also used for separation of sup 7 sup 5 Se and its isobar, sup 7 sup 5 As. A detailed description of the sample preparations, experimental setup and measurements are given. The re-measured half-life of sup 7 sup 9 Se was (2.95+-0.38)x10 sup 5 a, about a factor of 3 lower than the previous value, 1.1x10 sup 6 a. The problems in the previous measurement are discussed.

  15. High-precision half-life determination for the superallowed β+ emitter Ga62

    Science.gov (United States)

    Grinyer, G. F.; Finlay, P.; Svensson, C. E.; Ball, G. C.; Leslie, J. R.; Austin, R. A. E.; Bandyopadhyay, D.; Chaffey, A.; Chakrawarthy, R. S.; Garrett, P. E.; Hackman, G.; Hyland, B.; Kanungo, R.; Leach, K. G.; Mattoon, C. M.; Morton, A. C.; Pearson, C. J.; Phillips, A. A.; Ressler, J. J.; Sarazin, F.; Savajols, H.; Schumaker, M. A.; Wong, J.

    2008-01-01

    The half-life of the superallowed β+ emitter Ga62 has been measured at TRIUMF's Isotope Separator and Accelerator facility using a fast-tape-transport system and 4π continuous-flow gas proportional counter to detect the positrons from the decay of Ga62 to the daughter Zn62. The result, T1/2=116.100±0.025 ms, represents the most precise measurement to date (0.022%) for any superallowed β-decay half-life. When combined with six previous measurements of the Ga62 half-life, a new world average of T1/2=116.121±0.021 ms is obtained. This new half-life measurement results in a 20% improvement in the precision of the Ga62 superallowed ft value while reducing its mean by 0.9σ to ft=3074.3(12) s. The impact of this half-life measurement on precision tests of the CVC hypothesis and isospin symmetry breaking corrections for A⩾62 superallowed decays is discussed.

  16. Determination of plutonium-241 half-life by mass spectrometric measurement

    International Nuclear Information System (INIS)

    Hiyama, Takashi; Wada, Yukio; Onishi, Koichi

    1982-01-01

    Much data for Pu-241 half-life have been reported, but these values range from 13.8 years to 15.1 years depending on investigators. In order to define the half-life of Pu-241, the half-life was calculated by analyzing the mass spectrometry data obtained in the author's laboratory over the past six years on Plutonium Isotopic Standard Reference Materials prepared at the National Bureau of Standards (NBS). The sample used for this work consisted of SRM-947 and SRM-948 prepared at NBS. Before mass spectrometric analysis, the plutonium aliquot was separated from its Am-241 daughter by anion exchange chromatography, since Am-241 is not distinguished from Pu-241 in the mass spectrometer. 241 Pu/ 239 Pu and 241 Pu/ 240 Pu ratios were calculated from the values of mass spectrometric measurement. From the relation of log N to time, the half-life of Pu-241 was determined, based on the slope using a least squares fit. The half-life of Pu-241 was estimated to be 14.29+-0.15 years. (Yoshitake, I.)

  17. Design a 10 kJ IS Mather Type Plasma Focus for Solid Target Activation to Produce Short-Lived Radioisotopes 12C(d,n)13N

    Science.gov (United States)

    Sadat Kiai, S. M.; Adlparvar, S.; Sheibani, S.; Elahi, M.; Safarien, A.; Farhangi, S.; Zirak, A. R.; Alhooie, S.; Mortazavi, B. N.; Khalaj, M. M.; Khanchi, A. R.; Dabirzadeh, A. A.; Kashani, A.; Zahedi, F.

    2010-10-01

    A 10 kJ (15 kV, 88 μF) IS (Iranian Sun) Mather type plasma focus device has been studied to determine the activity of a compound exogenous carbon solid target through 12C(d,n)13N nuclear reaction. The produced 13N is a short-lived radioisotope with a half-life of 9.97 min and threshold energy of 0.28 MeV. The results indicate that energetic deuterons impinging on the solid target can produce yield of = 6.7 × 10-5 with an activity of A = 6.8 × 104 Bq for one plasma focus shut and A ν = 4 × 105 Bq for 6 shut per mint when the projectile maximum deuterons energy is E max = 3 MeV.

  18. An albumin-oligonucleotide assembly for potential combinatorial drug delivery and half-life extension applications

    DEFF Research Database (Denmark)

    Kuhlmann, Matthias; Hamming, Jonas Bohn Refslund; Voldum, Anders

    2017-01-01

    The long blood circulatory property of human serum albumin, due to engagement with the cellular recycling neonatal Fc receptor (FcRn), is an attractive drug half-life extension enabling technology. This work describes a novel site-specific albumin double-stranded (ds) DNA assembly approach, in wh...... technology platform that offers potential combinatorial drug delivery and half-life extension applications.......The long blood circulatory property of human serum albumin, due to engagement with the cellular recycling neonatal Fc receptor (FcRn), is an attractive drug half-life extension enabling technology. This work describes a novel site-specific albumin double-stranded (ds) DNA assembly approach......, in which the 3' or 5' end maleimide-derivatized oligodeoxynucleotides are conjugated to albumin cysteine at position 34 (cys34) and annealed with complementary strands to allow single site-specific protein modification with functionalized ds oligodeoxynucleotides. Electrophoretic gel shift assays...

  19. The elimination half-life of benzodiazepines and fall risk: two prospective observational studies.

    Science.gov (United States)

    de Vries, Oscar J; Peeters, Geeske; Elders, Petra; Sonnenberg, Caroline; Muller, Majon; Deeg, Dorly J H; Lips, Paul

    2013-11-01

    the STOPP criteria advise against the use of long-acting benzodiazepines (LBs). to study whether LBs are associated with a higher fall risk than short-acting benzodiazepines (SBs) (elimination half-life ≤ 10 h). we used base-line data and prospective fall follow-up from the Longitudinal Aging Study Amsterdam, a longitudinal cohort study including 1,509 community-dwelling older persons (Study 1) and from a separate fall prevention study with 564 older persons after a fall (Study 2). Time to the first fall after inclusion and number of falls in the first year after inclusion were the primary endpoints. both in Study 1 and Study 2 the use of SBs was associated with time to the first fall, hazard ratio (HR) 1.62 (95% CI: 1.03-2.56) and HR 1.64 (95% CI: 1.19-2.26),respectively. LBs were not significantly associated with time to first fall, HR 1.40 (0.85-2.31) and HR 1.08 (0.72-1.62). In both studies, the use of SBs was also associated with number of falls, odds ratio (OR) 1.28 (95% CI: 1.01-1.61) and OR 1.37 (95% CI: 1.10-1.70). LBs were not significantly associated with number of falls, OR 1.23 (0.96-1.57) and 1.10 (0.82-1.48). the use of SBs is not associated with a lower fall risk compared with LBs. The use of both SBs and LBs by old persons should be strongly discouraged.

  20. Improving the control of systematic uncertainties in precision measurements of radionuclide half-life

    International Nuclear Information System (INIS)

    Towers, S.

    2013-01-01

    Many experiments designed to precisely determine the half-life of a radionuclide employ a long lived reference source to help determine the impact on the data of any systematic variation in the detector and associated electronics. The half-life of the radionuclide of interest is determined from the ratio of its decay rate data to the decay rate data from the reference source. This correction procedure assumes that any underlying systematic affects the data and reference measurements in exactly the same way. In this paper we show that when some systematic effects affect the two differently, the ratio procedure can leave artifacts in the corrected data that can compromise an unbiased and precise assessment of the radionuclide half-life. We describe two methods that can help overcome this problem. We also describe several statistical tests that help determine which effects may underlie systematic variations in the data. We discuss an illustrative example based on previously published 32 Si and 36 Cl data recorded by an experiment at Brookhaven National Laboratory. We correct the data for systematic variation related to climate variation and estimate the 32 Si half-life to be T 1/2 =171.8±1.8. The reduction in uncertainty in the 32 Si half-life, relative to the previous estimate based upon this data, is equivalent to that which would be achieved through increasing the size of the data set by almost 3.5 times. - Author-Highlights: • Isotope decay data and reference source data can have differing systematics. • Differing systematics can inflate uncertainty of isotope half-life estimate. • We describe two methods to overcome this problem. • We describe statistical tests to determine which variables cause systematics. • We analyze Brookhaven 32Si/36Cl decay data as an illustrative example

  1. Precision half-life measurement of 11C: The most precise mirror transition F t value

    Science.gov (United States)

    Valverde, A. A.; Brodeur, M.; Ahn, T.; Allen, J.; Bardayan, D. W.; Becchetti, F. D.; Blankstein, D.; Brown, G.; Burdette, D. P.; Frentz, B.; Gilardy, G.; Hall, M. R.; King, S.; Kolata, J. J.; Long, J.; Macon, K. T.; Nelson, A.; O'Malley, P. D.; Skulski, M.; Strauss, S. Y.; Vande Kolk, B.

    2018-03-01

    Background: The precise determination of the F t value in T =1 /2 mixed mirror decays is an important avenue for testing the standard model of the electroweak interaction through the determination of Vu d in nuclear β decays. 11C is an interesting case, as its low mass and small QE C value make it particularly sensitive to violations of the conserved vector current hypothesis. The present dominant source of uncertainty in the 11CF t value is the half-life. Purpose: A high-precision measurement of the 11C half-life was performed, and a new world average half-life was calculated. Method: 11C was created by transfer reactions and separated using the TwinSol facility at the Nuclear Science Laboratory at the University of Notre Dame. It was then implanted into a tantalum foil, and β counting was used to determine the half-life. Results: The new half-life, t1 /2=1220.27 (26 ) s, is consistent with the previous values but significantly more precise. A new world average was calculated, t1/2 world=1220.41 (32 ) s, and a new estimate for the Gamow-Teller to Fermi mixing ratio ρ is presented along with standard model correlation parameters. Conclusions: The new 11C world average half-life allows the calculation of a F tmirror value that is now the most precise value for all superallowed mixed mirror transitions. This gives a strong impetus for an experimental determination of ρ , to allow for the determination of Vu d from this decay.

  2. The impact of extended half-life versus conventional factor product on hemophilia caregiver burden.

    Science.gov (United States)

    Schwartz, Carolyn E; Powell, Victoria E; Su, Jun; Zhang, Jie; Eldar-Lissai, Adi

    2018-05-01

    Extended half-life factor products have reduced annualized bleeding rates in hemophilia patients. The impact of extended half-life versus conventional factor products on hemophilia caregiver burden has not been investigated. This study aimed to evaluate caregiver burden in extended half-life versus conventional factor products for hemophilia A and B. This cross-sectional web-based study of caregivers of people with hemophilia A or B was recruited from a panel research company and by word of mouth. Participants completed the Hemophilia Caregiver Impact measure, the PedsQL Family Impact Module (PedsQL), and the Work Productivity and Activity Impairment Questionnaire (WPAI). We also collected demographic, insurance coverage, and medical information related to the hemophilia patient(s). Burden differences were assessed using linear regression and matched cohort analyses. The sample (n = 448) included 49 people who were caring for people on extended half-life factor products. Worse caregiver burden was associated with more infusions per week and more bleeds in the past 6 months. Regression analyses suggested that caring for someone who is on a extended half-life factor product is associated with lower emotional impact (β = - 0.11, p factor product had lower Emotional Impact and Practical Impact scores (t = - 2.95 and - 2.94, respectively, p factor product infusions of extended half-life factor products appears to reduce the emotional distress and practical burden of caregiving. Future work should evaluate the longitudinal impact.

  3. Determination of half life of tellurium isotopes: a proposal for the teaching of nuclear physics

    International Nuclear Information System (INIS)

    Ruivo, Julio C.; Zamboni, Cibele B.; Batista, Wagner F.

    2013-01-01

    This work aimed at the development of courseware for teaching nuclear physics, using experimental data of half-life measurement (T1/2) of Tellurium isotopes (A=127 and 131). The choice of Tellurium was established for providing nuclear data, which are fundamental in related investigations of nuclear structure and its use in various areas such as geochemistry, chemical and pharmaceutical industries, astrophysics etc. For evaluation of the proposal performance, the material was made available, bringing a lot of information about nuclear safety, production and storage of radioactive material and concepts of radioactive decay, subatomic particles, emission of gamma radiation, half-life, etc.

  4. Determination of half life of tellurium isotopes: a proposal for the teaching of nuclear physics

    Energy Technology Data Exchange (ETDEWEB)

    Ruivo, Julio C.; Zamboni, Cibele B.; Batista, Wagner F., E-mail: julio.ruivo.costa@usp.br, E-mail: czamboni@ipen.br, E-mail: fisicawagner@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    This work aimed at the development of courseware for teaching nuclear physics, using experimental data of half-life measurement (T1/2) of Tellurium isotopes (A=127 and 131). The choice of Tellurium was established for providing nuclear data, which are fundamental in related investigations of nuclear structure and its use in various areas such as geochemistry, chemical and pharmaceutical industries, astrophysics etc. For evaluation of the proposal performance, the material was made available, bringing a lot of information about nuclear safety, production and storage of radioactive material and concepts of radioactive decay, subatomic particles, emission of gamma radiation, half-life, etc.

  5. Application of genetic algorithms for determination biological half-life of 137 Cs in milk

    International Nuclear Information System (INIS)

    Pantelic, G.

    1998-01-01

    Genetic algorithm an optimization method involving natural selection mechanisms, was used to determine biological half-life of sup 1 sup 3 sup 7 Cs in the milk, after the Chernobyl accident, based on a two compartment linear system model. Genetic algorithms operate on populations of strings. Reproduction, crossover and mutation are applied to successive string population to create new string population. A model parameter estimation is performed by minimizing square differences between fitting function and experimental data. The calculated biological half-life of sup 1 sup 3 sup 7 Cs in milk is (32(+(-) days (author)

  6. Study of the half-life of 123I and the determination of possible radionuclidic impurities

    International Nuclear Information System (INIS)

    Delgado, Jose Ubiratan; Araujo, Miriam Taina Ferreira de; Silva, Carlos Jose da; Araujo, Camila Cristina Cunha; Candido, Marcos Antonio; Pereira, Wagner do Prado

    2013-01-01

    During the process of production of the radiopharmaceutical nuclear reactor or cyclotron, impurities can be generated from biological, chemical and radionuclidic. The development of the present work was to study the half-life of Na 123 I sample produced in IEN (Institute of Nuclear Engineering) using the technique of gamma-ray spectrometry with germanium detector in order to Identify such impurities. The results Indicate values of half-life consistent with recent publications with a deviation of 0,08% and 0:11% of uncertainty as well as the identification of impurities to radionuclides 95m Tc, 96 Tc and 121 Te. (author)

  7. An improved method for determination of technetium-99m half-life for the quality assurance procedures of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Abd Jalil Abd Hamid; Juhari Mohd Yusof; Zakaria Ibrahim; Wan Mohd Ferdaus Wan Ishak; Mohamad Hafiz Ahmad

    2009-01-01

    An improve method for identity tests of technetium-99m for the quality assurance procedures are presented. Computerized methods based on the least-squares of decay curve fitting for half-life estimation of technetium-99m was tested. Thus, least-squares method was employ as a decay curve fitting procedures in our software. Theoretical calculated half-life of technetium-99m for evaluation was performed for comparison. In Fig. 3 is shown, the decay curve fitting of a sample over one second counting time interval. The R2 value of the curve suggests that the time of the study was too short to obtain acceptable value. A similar measurement for another data set was done for a longer period of time and in Table 1 is shown a representative decay curve fitting. The value was found to be 6.006 hours with a discrepancy of -0.28% from the value taken from the literature. The value is in agreement with the literature for time interval greater than 2 seconds. The results obtained by this method show that the used of least-squares method for decay curve fitting are appropriate for routine identity tests. This confirmed that the least-squares method applied in our decay curve fitting software are remarkably improved and convenient for routine identity tests purposes. (Author)

  8. Focus on the legislative approach to short half life radioactive hospital waste releasing.

    Science.gov (United States)

    Petrucci, Caterina; Traino, Antonio Claudio

    2015-11-01

    We propose to summarize the advancements introduced by the new Directive 2013/59/Euratom concerning the concept of clearance, for which the radioactive medical waste represents a typical candidate. We also intend to spotlight disputable points in the regulatory scheme in force in Italy, as well to make a contribution to evaluate whether the practice of patients' urine storing, stated by it, can be regarded to be proper. With directing our interest to radionuclides used in Nuclear Medicine, we first present an overview of how the clearance concept, and that of exemption closely related to it, have been developed from the previous Directive 96/29 to the new one; then we describe the implementation of these concepts in the Italian legislation. Subsequently we estimate the exposure due both to keeping the effluent on site and to direct discharging it to the environment. In line with a well established international consensus, the Directive 2013/59 drives simple and harmonized regulation of clearance. On the contrary, some complexity and lack of consistency can be found in the framework of the national legislation affecting the radioactive medical waste handling. In addition the practice of excreta storing is disputed not to be really beneficial. The opportunity should be taken to make the whole system of these requirements simpler and more consistent and effective when it is revised to transpose the new Directive. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  9. Endogenous compounds labeled with radionuclides of short half-life-some perspectives

    DEFF Research Database (Denmark)

    Roland Långström, Bengt; Karimi, F; Watanabe, Y

    2013-01-01

    In the article, the strategy and synthesis of some endogenous compounds labeled mainly with (11) C are presented. There are some examples illustrating how endogenous labeled compounds in connection with positron emission tomography have unique properties to describe various biological processes......, and a few examples of the use of tracers labeled with (13) N and (15) O are also discussed. Labeled endogenous compounds may be an important asset to describe the conditions and the status of biological systems and might therefore be a key for the future search of individualized medicine....

  10. Automated spectrometer interface for measurement of short half-life samples for neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lapolli, André L.; Secco, Marcello; Genezini, Frederico A.; Zahn, Guilherme S.; Moreira, Edson G., E-mail: alapolli@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    In this paper a source positioning system was developed, based on a HPGe detector coupled to a Canberra DAS 1000 data acquisition system and Canberra's GENIE2K software and libraries. The system is composed of a step motor coupled to an Arduino Uno microcontroller, which is programmed using C language to allow for a source-detector distance between 0.3 and 20 cm - both components are coupled to a PC computer using the USB interface. In order to allow automated data acquisition, two additional pieces of software were developed. The first one, a Human-Machine Interface (HMI) programmed in Visual Basic 6, allows the programming and monitoring of the data acquisition process, and the other, in REXX language, controls the data acquisition process in the background. The HMI is user-friendly and versatile, so that the even rather complex data acquisition processes may be easily programmed. When the experiment scheme is saved, two files are created and used by the REXX code to control the acquisition process so that the data acquisition is automatically stopped and saved after a user-defined time, then the source is repositioned and data acquisition is cleared and restarted. While in the present stage the system only offers three distinct source positions, finer source-position adjusting is under development. In its present configuration the system has been tested for stability and repeatability in all three positions, with an an excellent performance (author)

  11. Methods of separating short half-life radionuclides from a mixture of radionuclides

    International Nuclear Information System (INIS)

    Bray, L.A.; Ryan, J.L.

    1998-01-01

    The present invention is a method of obtaining a radionuclide product selected from the group consisting of 223 Ra and 225 Ac, from a radionuclide ''cow'' of 227 Ac or 229 Th respectively. The method comprises the steps of (a) permitting ingrowth of at least one radionuclide daughter from said radionuclide ''cow'' forming an ingrown mixture; (b) insuring that the ingrown mixture is a nitric acid ingrown mixture; (c) passing the nitric acid ingrown mixture through a first nitrate form ion exchange column which permits separating the ''cow'' from at least one radionuclide daughter; (d) insuring that the at least one radionuclide daughter contains the radionuclide product; (e) passing the at least one radionuclide daughter through a second ion exchange column and separating the at least one radionuclide daughter from the radionuclide product and (f) recycling the at least one radionuclide daughter by adding it to the ''cow''. In one embodiment the radionuclide ''cow'' is the 227 Ac, the at least one daughter radionuclide is a 227 Th and the product radionuclide is the 223 Ra and the first nitrate form ion exchange column passes the 227 Ac and retains the 227 Th. In another embodiment the radionuclide ''cow'' is the 229 Th, the at least one daughter radionuclide is a 225 Ra and said product radionuclide is the 225 Ac and the 225 Ac and nitrate form ion exchange column retains the 229 Th and passes the 225 Ra/Ac. 8 figs

  12. Methods of separating short half-life radionuclides from a mixture of radionuclides

    Science.gov (United States)

    Bray, Lane A.; Ryan, Jack L.

    1998-01-01

    The present invention is a method of obtaining a radionuclide product selected from the group consisting of .sup.223 Ra and .sup.225 Ac, from a radionuclide "cow" of .sup.227 Ac or .sup.229 Th respectively. The method comprises the steps of a) permitting ingrowth of at least one radionuclide daughter from said radionuclide "cow" forming an ingrown mixture; b) insuring that the ingrown mixture is a nitric acid ingrown mixture; c) passing the nitric acid ingrown mixture through a first nitrate form ion exchange column which permits separating the "cow" from at least one radionuclide daughter; d) insuring that the at least one radionuclide daughter contains the radionuclide product; e) passing the at least one radionuclide daughter through a second ion exchange column and separating the at least one radionuclide daughter from the radionuclide product and f) recycling the at least one radionuclide daughter by adding it to the "cow". In one embodiment the radionuclide "cow" is the .sup.227 Ac, the at least one daughter radionuclide is a .sup.227 Th and the product radionuclide is the .sup.223 Ra and the first nitrate form ion exchange column passes the .sup.227 Ac and retains the .sup.227 Th. In another embodiment the radionuclide "cow"is the .sup.229 Th, the at least one daughter radionuclide is a .sup.225 Ra and said product radionuclide is the .sup.225 Ac and the .sup.225 Ac and nitrate form ion exchange column retains the .sup.229 Th and passes the .sup.225 Ra/Ac.

  13. Automated spectrometer interface for measurement of short half-life samples for neutron activation analysis

    International Nuclear Information System (INIS)

    Lapolli, André L.; Secco, Marcello; Genezini, Frederico A.; Zahn, Guilherme S.; Moreira, Edson G.

    2017-01-01

    In this paper a source positioning system was developed, based on a HPGe detector coupled to a Canberra DAS 1000 data acquisition system and Canberra's GENIE2K software and libraries. The system is composed of a step motor coupled to an Arduino Uno microcontroller, which is programmed using C language to allow for a source-detector distance between 0.3 and 20 cm - both components are coupled to a PC computer using the USB interface. In order to allow automated data acquisition, two additional pieces of software were developed. The first one, a Human-Machine Interface (HMI) programmed in Visual Basic 6, allows the programming and monitoring of the data acquisition process, and the other, in REXX language, controls the data acquisition process in the background. The HMI is user-friendly and versatile, so that the even rather complex data acquisition processes may be easily programmed. When the experiment scheme is saved, two files are created and used by the REXX code to control the acquisition process so that the data acquisition is automatically stopped and saved after a user-defined time, then the source is repositioned and data acquisition is cleared and restarted. While in the present stage the system only offers three distinct source positions, finer source-position adjusting is under development. In its present configuration the system has been tested for stability and repeatability in all three positions, with an an excellent performance (author)

  14. Method of separating short half-life radionuclides from a mixture of radionuclides

    Science.gov (United States)

    Bray, L.A.; Ryan, J.L.

    1999-03-23

    The present invention is a method of removing an impurity of plutonium, lead or a combination thereof from a mixture of radionuclides that contains the impurity and at least one parent radionuclide. The method has the steps of (a) insuring that the mixture is a hydrochloric acid mixture; (b) oxidizing the acidic mixture and specifically oxidizing the impurity to its highest oxidation state; and (c) passing the oxidized mixture through a chloride form anion exchange column whereupon the oxidized impurity absorbs to the chloride form anion exchange column and the {sup 229}Th or {sup 227}Ac ``cow`` radionuclide passes through the chloride form anion exchange column. The plutonium is removed for the purpose of obtaining other alpha emitting radionuclides in a highly purified form suitable for medical therapy. In addition to plutonium, lead, iron, cobalt, copper, uranium, and other metallic cations that form chloride anionic complexes that may be present in the mixture are removed from the mixture on the chloride form anion exchange column. 8 figs.

  15. Intrinsically Disordered Segments Affect Protein Half-Life in the Cell and during Evolution

    Directory of Open Access Journals (Sweden)

    Robin van der Lee

    2014-09-01

    Full Text Available Precise control of protein turnover is essential for cellular homeostasis. The ubiquitin-proteasome system is well established as a major regulator of protein degradation, but an understanding of how inherent structural features influence the lifetimes of proteins is lacking. We report that yeast, mouse, and human proteins with terminal or internal intrinsically disordered segments have significantly shorter half-lives than proteins without these features. The lengths of the disordered segments that affect protein half-life are compatible with the structure of the proteasome. Divergence in terminal and internal disordered segments in yeast proteins originating from gene duplication leads to significantly altered half-life. Many paralogs that are affected by such changes participate in signaling, where altered protein half-life will directly impact cellular processes and function. Thus, natural variation in the length and position of disordered segments may affect protein half-life and could serve as an underappreciated source of genetic variation with important phenotypic consequences.

  16. Radionuclide biological half-life values for terrestrial and aquatic wildlife

    International Nuclear Information System (INIS)

    Beresford, N.A.; Beaugelin-Seiller, K.; Burgos, J.; Cujic, M.; Fesenko, S.; Kryshev, A.; Pachal, N.; Real, A.; Su, B.S.; Tagami, K.; Vives i Batlle, J.; Vives-Lynch, S.; Wells, C.; Wood, M.D.

    2015-01-01

    The equilibrium concentration ratio is typically the parameter used to estimate organism activity concentrations within wildlife dose assessment tools. Whilst this is assumed to be fit for purpose, there are scenarios such as accidental or irregular, fluctuating, releases from licensed facilities when this might not be the case. In such circumstances, the concentration ratio approach may under- or over-estimate radiation exposure depending upon the time since the release. To carrying out assessments for such releases, a dynamic approach is needed. The simplest and most practical option is representing the uptake and turnover processes by first-order kinetics, for which organism- and element-specific biological half-life data are required. In this paper we describe the development of a freely available international database of radionuclide biological half-life values. The database includes 1907 entries for terrestrial, freshwater, riparian and marine organisms. Biological half-life values are reported for 52 elements across a range of wildlife groups (marine = 9, freshwater = 10, terrestrial = 7 and riparian = 3 groups). Potential applications and limitations of the database are discussed. - Highlights: • 1907 biological half-life values have been collated for wildlife species. • Data cover 52 elements. • 27 marine, freshwater, riparian and terrestrial organisms are included.

  17. Intrinsically disordered segments and the evolution of protein half-life

    Science.gov (United States)

    Babu, M.

    2013-03-01

    Precise turnover of proteins is essential for cellular homeostasis and is primarily mediated by the proteasome. Thus, a fundamental question is: What features make a protein an efficient substrate for degradation? Here I will present results that proteins with a long terminal disordered segment or internal disordered segments have a significantly shorter half-life in yeast. This relationship appears to be evolutionarily conserved in mouse and human. Furthermore, upon gene duplication, divergence in the length of terminal disorder or variation in the number of internal disordered segments results in significant alteration of the half-life of yeast paralogs. Many proteins that exhibit such changes participate in signaling, where altered protein half-life will likely influence their activity. We suggest that variation in the length and number of disordered segments could serve as a remarkably simple means to evolve protein half-life and may serve as an underappreciated source of genetic variation with important phenotypic consequences. MMB acknowledges the Medical Research Council for funding his research program.

  18. Safety and Efficacy of BAY 94-9027, a Prolonged-Half-Life Factor VIII

    DEFF Research Database (Denmark)

    Reding, M T; Ng, H J; Poulsen, Lone Hvitfeldt

    2017-01-01

    BACKGROUND: BAY 94-9027 is a B-domain-deleted prolonged-half-life recombinant factor VIII (FVIII) conjugates in a site-specific manner with polyethylene glycol. OBJECTIVE: Assess efficacy and safety of BAY 94-9027 for prophylaxis and treatment of bleeds in patients with severe hemophilia A PATIEN...

  19. Effect of parent and daughter deformation on half-life time in exotic ...

    Indian Academy of Sciences (India)

    Shi and Swiatecki [6] put forward a model for exotic decay studies that uses Coulomb and proximity potential as interacting barrier for post-scission region and uses simple power law for overlap region. These authors [7] studied the effect of deformation of parent, daughter and shell attenuation on half-life time treating ...

  20. Dependence of the half-life of 221Fr on the implantation environment

    DEFF Research Database (Denmark)

    Olaizola, B.; Fraile, L.M.; Riisager, Karsten

    2010-01-01

    The possible dependence of the half-life of 221Fr on the solid-state environment has been investigated by the simultaneous measurement of implanted 221Fr ions in an insulator (Si) and a metallic substrate (Au) at the ISOLDE facility at CERN. Our results indicate that, if existing, the difference ...

  1. Precision half-life measurement of .sup.140 La with Ge-detector

    Czech Academy of Sciences Publication Activity Database

    Adam, Jindřich; Belov, A. G.; Brandt, R.; Chaloun, P.; Honusek, Milan; Kalinnikov, V. G.; Krivopustov, M. I.; Kulakov, B. A.; Langrock, E. J.; Pronskikh, V. S.; Sosnin, A. N.; Stegailov, V. I.; Tsoupko-Sitnikov, V. M.; Wan, J. S.; Westmeier, W.

    2002-01-01

    Roč. 187, - (2002), s. 419-426 ISSN 0168-583X R&D Projects: GA AV ČR KSK1048102 Keywords : radioastive nuclei * Ge-detectors * half-life measurements Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.158, year: 2002

  2. Lithium as an adjunct to radioiodine therapy in Graves' disease for prolonging the intrathyroidal effective half-life of radioiodine. Useful or not?

    Energy Technology Data Exchange (ETDEWEB)

    Dunkelmann, S.; Kuenstner, H.; Nabavi, E.; Eberlein, U.; Groth, P.; Schuemichen, C. [Rostock Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin, Zentrum fuer Radiologie

    2006-07-01

    Aim: Evaluation of intrathyroidal kinetics of radioiodine with and without lithium as adjunct with respect to the increase in radiation dose delivered to the thyroid. Patients, methods: 267 patients in three groups were included in the study. Group I with 227 patients served as control group, Group II with 21 patients and Group III with 19 patients were distinguished by an intrathyroidal half-life of radioiodine below 3.5 days in the diagnostic test. Patients in Group III received 885 mg lithium carbonate a day for 2 weeks as adjunct to radioiodine therapy. Both diagnostic and therapeutic radioiodine kinetics were followed up by at least 10 uptake measurements within a minimum of 48 h. Kinetics of radioiodine were defined mathematically as balance of the thyroidal iodine intake and excretion by a two-compartment model. Results: Under therapy the maximum uptake of radioiodine was reduced by nearly 10% in all groups, in Group I, the effective half-life as well as the product of maximum uptake x effective half-life as an equivalent of radiation dose independent of thyroid volume was lowered in the same magnitude. In Group II, the energy-dose equivalent remained constant under therapy. With adjunct lithium in Group III, the effective half-life was prolonged significantly by factor 1.61{+-}0.49 and the volume-independent energy-dose equivalent by factor 1.39{+-}0.37. No severe side effects of lithium were observed. Conclusion: Using lithium as adjunct to radio-iodine therapy increases the radiation dose delivered to the thyroid by 39% on average and nearly 30% of radioiodine activity can be saved in these patients. Lithium is recommended in patients with very short effective half-life in the diagnostic test in order to reduce the activity required and whole-body radiation dose. (orig.)

  3. Nondispersive x-ray diagnostics of short lived plasmas

    International Nuclear Information System (INIS)

    Day, R.H.

    1983-01-01

    In this NATO Advanced Study Institute, we have discussed in detail the diagnosis of many pulse power machine properties, including their electrical behavior, grounding and shielding, and related data acquisition techniques. The purpose for many of these machines is to create high temperature/high density plasmas and, therefore, the subsequent behavior of these plasmas is of critical concern. The energy density of these plasmas is such that they will naturally radiate in the x-ray regime and thus the diagnosis of their x-ray emission is a crucial measurement of the entire system performance. In this lecture, I describe the general techniques used to perform nondispersive x-ray diagnostics of these short lived plasmas

  4. On the half-life of luminescence signals in dosimetric applications: A unified presentation

    Science.gov (United States)

    Pagonis, V.; Kitis, G.; Polymeris, G. S.

    2018-06-01

    Luminescence signals from natural and man-made materials are widely used in dosimetric and dating applications. In general, there are two types of half-lives of luminescence signals which are of importance to experimental and modeling work in this research area. The first type of half-life is the time required for the population of the trapped charge in a single trap to decay to half its initial value. The second type of half-life is the time required for the luminescence intensity to drop to half of its initial value. While there a handful of analytical expressions available in the literature for the first type of half-life, there are no corresponding analytical expressions for the second type. In this work new analytical expressions are derived for the half-life of luminescence signals during continuous wave optical stimulation luminescence (CW-OSL) or isothermal luminescence (ITL) experiments. The analytical expressions are derived for several commonly used luminescence models which are based on delocalized transitions involving the conduction band: first and second order kinetics, empirical general order kinetics (GOK), mixed order kinetics (MOK) and the one-trap one-recombination center (OTOR) model. In addition, half-life expressions are derived for a different type of luminescence model, which is based on localized transitions in a random distribution of charges. The new half-life expressions contain two parts. The first part is inversely proportional to the thermal or optical excitation rate, and depends on the experimental conditions and on the cross section of the relevant luminescence process. The second part is characteristic of the optical and/or thermal properties of the material, as expressed by the parameters in the model. A new simple and quick method for analyzing luminescence signals is developed, and examples are given of applying the new method to a variety of dosimetric materials. The new test allows quick determination of whether a set of

  5. Validation of effective half-life of tritium and computation of dose at Madras Atomic Power Station

    International Nuclear Information System (INIS)

    Moolya, L.L.; Kannan, R.K.; Sreekumaran Nair, B.; Mohandas, P.G.; Rajan, R.

    2001-01-01

    In Pressurised Heavy Water Reactors (PHWRs) tritium is produced by the activation of deuterium present in the moderator and coolant system. Hence, the inventory of tritium in PHWR is high and it contributes about 20 percent of the Station Dose. Tritium enters body by inhalation, ingestion and skin absorption. Dose received by an individual depends on its elimination rate from the body and hence the effective half-life. It is found that the effective half-life varies from person to person. The effective half-life also depends on the weather condition. The variation of effective half-life is taken care of in dose estimation by average method. However, in case of dose calculation for single uptake cases, there is a need to take fixed effective half-life. ICRP has taken the effective half-life as 10 days. The effective half-life is taken as 6 days in Indian conditions based on the studies conducted earlier in MAPS and elsewhere. Now with available data for about 16 years a fresh study was conducted to validate the effective half-life. This paper gives the study of effective half-life of tritium and its variation during different seasons of the year in MAPS. This paper also gives methods used for computing dose due to tritium. (author)

  6. A half-life the divided life of Bruno Pontecorvo, physicist or spy

    CERN Document Server

    Close, Frank

    2015-01-01

    Bruno Pontecorvo dedicated his career to hunting for the Higgs boson of his day: the neutrino, a nearly massless particle considered essential to the process of nuclear fission. His work on the Manhattan project under Enrico Fermi confirmed his reputation as a brilliant physicist and helped usher in the nuclear age. He should have won a Nobel Prize, but late in the summer of 1950 he vanished. At the height of the Cold War, Pontecorvo had disappeared behind the Iron Curtain. In Half-Life, physicist and historian Frank Close offers a heretofore untold history of Pontecorvo’s life, based on unprecedented access to his friends, family, and colleagues. With all the elements of a Cold War thriller—classified atomic research, an infamous double agent, a kidnapping by Soviet operatives—Half-Life is a history of particle physics at perhaps its most powerful: when it created the bomb.

  7. High-Precision Half-Life Measurement for the Superallowed β+ Emitter Alm26

    Science.gov (United States)

    Finlay, P.; Ettenauer, S.; Ball, G. C.; Leslie, J. R.; Svensson, C. E.; Andreoiu, C.; Austin, R. A. E.; Bandyopadhyay, D.; Cross, D. S.; Demand, G.; Djongolov, M.; Garrett, P. E.; Green, K. L.; Grinyer, G. F.; Hackman, G.; Leach, K. G.; Pearson, C. J.; Phillips, A. A.; Sumithrarachchi, C. S.; Triambak, S.; Williams, S. J.

    2011-01-01

    A high-precision half-life measurement for the superallowed β+ emitter Alm26 was performed at the TRIUMF-ISAC radioactive ion beam facility yielding T1/2=6346.54±0.46stat±0.60systms, consistent with, but 2.5 times more precise than, the previous world average. The Alm26 half-life and ft value, 3037.53(61) s, are now the most precisely determined for any superallowed β decay. Combined with recent theoretical corrections for isospin-symmetry-breaking and radiative effects, the corrected Ft value for Alm26, 3073.0(12) s, sets a new benchmark for the high-precision superallowed Fermi β-decay studies used to test the conserved vector current hypothesis and determine the Vud element of the Cabibbo-Kobayashi-Maskawa quark mixing matrix.

  8. High-Precision Half-life Measurements for the Superallowed β+ Emitter 14O

    Science.gov (United States)

    Laffoley, A. T.; Svensson, C. E.; Andreoiu, C.; Austin, R. A. E.; Ball, G. C.; Blank, B.; Bouzomita, H.; Cross, D. S.; Diaz Varela, A.; Dunlop, R.; Finlay, P.; Garnsworthy, A. B.; Garrett, P. E.; Giovinazzo, J.; Grinyer, G. F.; Hackman, G.; Hadinia, B.; Jamieson, D. S.; Ketelhut, S.; Leach, K. G.; Leslie, J. R.; Tardiff, E. R.; Thomas, J. C.; Unsworth, C.

    2014-03-01

    The half-life of 14O, a superallowed Fermi β+ emitter, has been determined via simultaneous γ and β counting experiments at TRIUMF's Isotope Separator and Accelerator facility. Following the implantation of 14O samples at the center of the 8π spectrometer, a γ counting measurement was performed by detecting the 2313 keV γ-rays emitted from the first excited state of the daughter 14N using 20 high-purity germanium (HPGe) detectors. A simultaneous β counting experiment was performed using a fast plastic scintillator positioned directly behind the implantation site. The results, T½(γ) = 70:632 ± 0:094 s and T½(β) = 70:610 ± 0:030 s, are consistent with one another and, together with eight previous measurements, establish a new average for the 14O half-life of T½ = 70:619 ± 0:011 s with a reduced χ2 of 0.99.

  9. Half-life and intensities of photons of 103Pd isotope

    International Nuclear Information System (INIS)

    Popov, Yu.S.; Zakharova, L.V.; Kupriyanov, V.N.; Andreev, O.I.; Pakhomov, A.N.; Vakhetov, F.Z.

    2001-01-01

    Half-life and intensities of photons forming during 103 Pd isotope decay are determined by the methods of semiconductor x-ray and γ-spectrometry. 103 Pd is applied in nuclear medicine for preparation of 103m Rh isomer (T 1/2 =56 min) being used in irradiation of prostate neoplasms. Half-life of 103 Pd isotope is 16±0.6 days, relative intensities of x-ray and γ-photons are: K α /Kβ=5.1±0.4; 358 keV - 100 rel.units; 295 keV - 12.3±0.4 rel.units; 497 keV - 17.6±0.6 rel.units. Errors are represented for confidence probability 95 % [ru

  10. A New Method to Determine the Half-Life for Penicillin Using Microcalorimeter

    Science.gov (United States)

    Li, Z. X.; Zhao, W. W.

    2015-01-01

    The dissolution process of penicillin in normal saline and isotonic glucose solution was reported using a microcalorimeter. Both the integral and differential heats of solution were measured. The quantitative relationships between the amount of heat released and the quantity of dissolved penicillin were established. Meanwhile, the kinetics and the half-life of the dissolution processes as well as the enthalpy of solution, the entropy of dissolution, and the free energy of dissolution were determined. The results showed that a change of the solvent from normal saline to isotonic glucose solution had little effect on the half-life of penicillin in the dissolution process, and there was no significant difference between the stabilities of penicillin in isotonic glucose solution and normal saline. Moreover, the dissolution process of penicillin in isotonic glucose solution followed the first-order kinetics. These results could provide a theoretical basis for the clinical applications of penicillin.

  11. Biological half-life of radiophosphorus in desert locust, Schistocerca gregaria Forskal (orthoptera:acrididae)

    International Nuclear Information System (INIS)

    Ulagaraj, S.M.; Singh, K.M.; Sethi, G.R.

    1975-01-01

    Adult desert locust, Schistocerca gregaria Forskal were fed with cabbage leaves, painted with carrier free 32 P 1mCi/ml. Radioactivity of five adults of both sexes and of feces was measured daily for 28 days. The amount of radioactivity appearing in the feces of males was consistently below that found in female locusts. The mean biological half-life of 32 P for males and females were 35.04 and 15.01 days, respectively. (author)

  12. Neutron activation analyses and half-life measurements at the usgs triga reactor

    Science.gov (United States)

    Larson, Robert E.

    Neutron activation of materials followed by gamma spectroscopy using high-purity germanium detectors is an effective method for making measurements of nuclear beta decay half-lives and for detecting trace amounts of elements present in materials. This research explores applications of neutron activation analysis (NAA) in two parts. Part 1. High Precision Methods for Measuring Decay Half-Lives, Chapters 1 through 8 Part one develops research methods and data analysis techniques for making high precision measurements of nuclear beta decay half-lives. The change in the electron capture half-life of 51Cr in pure chromium versus chromium mixed in a gold lattice structure is explored, and the 97Ru electron capture decay half-life are compared for ruthenium in a pure crystal versus ruthenium in a rutile oxide state, RuO2. In addition, the beta-minus decay half-life of 71mZn is measured and compared with new high precision findings. Density Functional Theory is used to explain the measured magnitude of changes in electron capture half-life from changes in the surrounding lattice electron configuration. Part 2. Debris Collection Nuclear Diagnostic at the National Ignition Facility, Chapters 9 through 11 Part two explores the design and development of a solid debris collector for use as a diagnostic tool at the National Ignition Facility (NIF). NAA measurements are performed on NIF post-shot debris collected on witness plates in the NIF chamber. In this application NAA is used to detect and quantify the amount of trace amounts of gold from the hohlraum and germanium from the pellet present in the debris collected after a NIF shot. The design of a solid debris collector based on material x-ray ablation properties is given, and calculations are done to predict performance and results for the collection and measurements of trace amounts of gold and germanium from dissociated hohlraum debris.

  13. Precise half-life measurement of the superallowed β+ emitter 38Km

    International Nuclear Information System (INIS)

    Ball, G. C.; Boisvert, G.; Bricault, P.; Churchman, R.; Dombsky, M.; Lindner, T.; Macdonald, J. A.; Vandervoort, E.; Bishop, S.; D'Auria, J. M.; Hardy, J. C.; Iacob, V. E.; Leslie, J. R.; Mak, H.-B.

    2010-01-01

    The half-life of 38 K m has been measured to be 924.46(14) ms, a result that is a factor of two more precise than any of the five previous measurements of this quantity. The previous results are not consistent with one another, but our result agrees well with the two most recent ones. The derived ft value for 38 K m is now one of the three most precisely known superallowed ft values.

  14. Increased Functional Half-life of Fibroblast Growth Factor-1 by Recovering a Vestigial Disulfide Bond

    Directory of Open Access Journals (Sweden)

    Jihun Lee

    2010-12-01

    Full Text Available The fibroblast growth factor (FGF family of proteins contains an absolutely conserved Cys residue at position 83 that is present as a buried free cysteine. We have previously shown that mutation of the structurally adjacent residue, Ala66, to cysteine results in the formation of a stabilizing disulfide bond in FGF-1. This result suggests that the conserved free cysteine residue at position 83 in the FGF family of proteins represents a vestigial half-cystine. Here, we characterize the functional half-life and mitogenic activity of the oxidized form of the Ala66Cys mutation to identify the effect of the recovered vestigial disulfide bond between Cys83 and Cys66 upon the cellular function of FGF-1. The results show that the mitogenic activity of this mutant is significantly increased and that its functional half-life is greatly extended. These favorable effects are conferred by the formation of a disulfide bond that simultaneously increases thermodynamic stability of the protein and removes a reactive buried thiol at position 83. Recovering this vestigial disulfide by introducing a cysteine at position 66 is a potentially useful protein engineering strategy to improve the functional half-life of other FGF family members.

  15. Measurements of Actual Effective Half - Life in 131I Therapy for Graves' Hyperthyroidism

    International Nuclear Information System (INIS)

    So, Yong Seon; Kim, Myung Seon; Kwon, Ki Hyun; Kim, Seok Whan; Kim, Tae Hyung; Han, Sang Woong; Kim, Eun Sil; Kim, Chong Soon

    1996-01-01

    Radioiodine[131I] has been used for the treatment of Graves' hyperthyroidism since the late 1940's and is now generally regarded as the treatment of choice for Graves' hyperthyroidism who does not remit following a course of antithyroid drugs. But for the dose given, several different protocols have been described by different centers, each attempting to reduce the incidence of long-term hypothyroidism while maintaining an acceptable rate control of Graves' hyperthyroidism. Our goals were to evaluate effective half-life and predict absorbed dose in Graves' hyperthyroidism patients, therefore, to calculate and read minister radioiodine activity needed to achieve aimed radiation dose. Our data showed that the mean effective 131I half-life for Graves' disease is 5.3 days(S.D=0.88) and mean biologic half-life is 21 days, range 9.5-67.2 days. The mean administered activity and the mean values of absorbed doses wet: 532 MBq(S.D.=254), 112 Gy (S.D.=50.9), respectively. The mean activity needed to achieve aimed radiation dose were 51 MBq and marked differences of 131I thyroidal uptake between tracer and therapy occurred in our study. We are sure that the dose calculation method that uses 5 days thyroidal 131I uptake measurements after tracer and therapy dose, provides sufficient data about the effective treatment in Graves' hyperthyroidism.

  16. Measurements of Actual Effective Half - Life in {sup 131}I Therapy for Graves' Hyperthyroidism

    Energy Technology Data Exchange (ETDEWEB)

    So, Yong Seon; Kim, Myung Seon; Kwon, Ki Hyun; Kim, Seok Whan; Kim, Tae Hyung; Han, Sang Woong; Kim, Eun Sil; Kim, Chong Soon [Hanil General Hospital, Seoul (Korea, Republic of)

    1996-03-15

    Radioiodine[131I] has been used for the treatment of Graves' hyperthyroidism since the late 1940's and is now generally regarded as the treatment of choice for Graves' hyperthyroidism who does not remit following a course of antithyroid drugs. But for the dose given, several different protocols have been described by different centers, each attempting to reduce the incidence of long-term hypothyroidism while maintaining an acceptable rate control of Graves' hyperthyroidism. Our goals were to evaluate effective half-life and predict absorbed dose in Graves' hyperthyroidism patients, therefore, to calculate and read minister radioiodine activity needed to achieve aimed radiation dose. Our data showed that the mean effective 131I half-life for Graves' disease is 5.3 days(S.D=0.88) and mean biologic half-life is 21 days, range 9.5-67.2 days. The mean administered activity and the mean values of absorbed doses wet: 532 MBq(S.D.=254), 112 Gy (S.D.=50.9), respectively. The mean activity needed to achieve aimed radiation dose were 51 MBq and marked differences of 131I thyroidal uptake between tracer and therapy occurred in our study. We are sure that the dose calculation method that uses 5 days thyroidal 131I uptake measurements after tracer and therapy dose, provides sufficient data about the effective treatment in Graves' hyperthyroidism.

  17. Ghrelin plasma levels in patients with idiopathic short stature.

    Science.gov (United States)

    Iñiguez, Germán; Román, Rossana; Youlton, Ronald; Cassorla, Fernando; Mericq, Verónica

    2011-02-01

    Novel molecular insights have suggested that ghrelin may be involved in the pathogenesis of some forms of short stature. Recently, growth hormone secretagogue receptor (GHSR) mutations that segregate with short stature have been reported. To study plasma ghrelin levels in prepubertal patients with idiopathic short stature (ISS). Fasting total plasma ghrelin levels (radioimmunoassay) in 41 prepubertal patients with ISS (18 females, age 7.9 ± 0.5 years) compared with 42 age- and sex-matched controls (27 females, age 8.0 ± 0.3 years) with normal height. In a subset of 28 patients, the ghrelin receptor was sequenced. ISS patients exhibited a higher level of ghrelin (1,458 ± 137 vs. 935 ± 55 pg/ml, p ghrelin levels greater than +2 SDS compared to controls. These patients did not differ in height, BMI or IGF-I SDS compared to ISS patients with ghrelin levels within the normal range. Molecular analysis of GHSR did not show any mutations, but showed some polymorphisms. These results suggest that in ISS patients, short stature does not appear to be frequently caused by abnormalities in ghrelin signaling. Copyright © 2010 S. Karger AG, Basel.

  18. Measurement of the half-life of sup 1 sup 7 sup 6 Lu

    CERN Document Server

    Nir-El, Y

    1998-01-01

    The half-life of sup 1 sup 7 sup 6 Lu was determined by measuring the disintegration rate of a solution of lutetium oxide, using a calibrated HPGe detector, and found to be (3.69+-0.02)x10 sup 1 sup 0 y. It is recommended that the current adopted value be calculated from the grouping of three published values since 1983, including our value, the weighted mean of which is (3.73+-0.01)x10 sup 1 sup 0 y.

  19. Half-life of the 3/2/sup +/ level of /sup 119/Sn

    Energy Technology Data Exchange (ETDEWEB)

    Abreu, M C; Gil, F B [Faculdade de Ciencias da Universidade de Lisboa, Lisbon (Portugal). Grupo de Espectroscopia Nuclear, Laboratorio de Fisica

    1976-01-01

    The half-life of the 3/2/sup +/, 23.87 keV level of /sup 119/Sn is measured by the delayed coincidence technique. Magnetic spectrometry associated with scintillation techniques and scintillation spectrometry only have been used. The results obtained with these techniques were respectively Tsub(1/2) = 17.87 +- 0.11 ns and Tsub(1/2) = 18.48 +- 0.30 ns. The measured reduced M1 transition probability is compared with the single-particle and Kisslinger and Sorensen model predictions.

  20. The Half Life of the 53 keV Level in {sup 197}Pt

    Energy Technology Data Exchange (ETDEWEB)

    Malmskog, S G

    1967-02-15

    The half life of the recently proposed 53 keV level in {sup 197}Pt has been measured to 18.5 {+-} 1.5 nsec using the delayed coincidence technique. This level, which is identified with the f{sub 5/2} single particle state, decays directly to the p{sub 1/2} ground state in {sup 197}Pt. The reduced E2 transition probability for this 53 keV transition has been deduced and compared with the results obtained for the corresponding transitions in other Pt, Hg, and Pb isotopes and with the theoretical predictions by Sorensen and by Wahlborn and Martinson.

  1. First 0ν half-life limit from the Gotthard xenon time projection chamber

    International Nuclear Information System (INIS)

    Wong, H.T.; Boehm, F.; Fisher, P.

    1991-01-01

    A xenon Time Projection Chamber with an active volume of 207 liters has been built to study 0ν and 2ν double beta decay in 136 Xe. The TPC has been installed in the Gotthard Tunnel Underground Laboratory, and is currently taking data with 5 atm of xenon enriched in 62.5% 136 Xe. The first 166 hours of data are presented. Based on this data set, we deduce a half-life limit of T(0 + → 0 + ) > 6.2 x 10 21 years for the 0ν mode, at a 90% C.L. (author)

  2. Precision half-life determination of a mirror β transition: The decay of 31S

    International Nuclear Information System (INIS)

    Bacquias, A.; Kurtukian-Nieto, T.; Ascher, P.; Audirac, L.; Blank, B.; Giovinazzo, J.; Aeystoe, J.; Elomaa, V.V.; Eronen, T.; Hakala, J.; Jokinen, A.; Kankainen, A.; Karvonen, P.; Kolhinen, V.S.; Moore, I.D.; Rahaman, S.; Reponen, M.; Rissanen, J.; Saastamoinen, A.; Souin, J.

    2012-01-01

    The half-life of the mirror β decay of 31 S has been measured at the IGISOL facility at the University of Jyvaeskylae. The value obtained is T 1/2 ( 31 S)=(2553.4±1.8) ms, in agreement with previous measurements, but with a precision that is better by a factor of ten than the literature value previously adopted. When the new result is combined with the Q EC value measured recently at JYFLTRAP, a precision of better than 10 -3 is obtained for the ft value. (orig.)

  3. Determination of the half-life of sup 1 sup 0 sup 5 sup m Rh

    CERN Document Server

    Kronenberg, A K; Weber, R; Esterlund, R A; Patzelt, P

    1998-01-01

    Following a fast chemical separation of Ru isotopes from a fission-product mixture, sup 1 sup 0 sup 5 sup m Rh was periodically extracted from its precursor (4.44-h sup 1 sup 0 sup 5 Ru) for measurements of its half-life. The new value for the T sub 1 sub / sub 2 of sup 1 sup 0 sup 5 sup m Rh of (43.0+-0.3) s resolves the long-standing conflict in the literature between the two earlier measured values of 45 and 30 s.

  4. Effect of change in half-life of Se-79 on the safety of HLW geological disposal system

    International Nuclear Information System (INIS)

    Ishihara, Yoshinao; Ishiguro, Katsuhiko; Umeki, Hiroyuki

    1999-11-01

    Se-79 is one of key radionuclides in the performance assessment of the geological disposal system. Based on recent measurements, it is possible that the half-life of Se-79 will be changed longer than the present value in most handbooks and tables of isotopes. This study presents performance assessment calculations to investigate the overall effect of change in half-life of Se-79 on the repository system safety. The total system performance analyses for Se-79 were carried out, which focussed on the Reference-Case of the safety assessment in the H12 Project. As results, the maximum release rate in Becquerel unit of Se-79 from the engineered barrier system with new half-life decreases about one order of magnitude than that with half-life used so far. It is, however, that the maximum release rate in Becquerel unit of Se-79 from the natural barrier system is almost same for both half-life because of the channelling effects of groundwater flow. Consequently, the calculated maximum dose rate of Se-79 with new half-life does not change. It can be concluded that the change in half-life of Se-79 does not affect overall safety of the H12 disposal concept. (author)

  5. Performance of Llampuedken with short circuit and plasma loads

    International Nuclear Information System (INIS)

    Chuaqui, Hernan; Mitchell, Ian H.; Aliaga-Rossel, Raul; Favre, Mario; Wyndham, Edmund S.

    2002-01-01

    Llampuedken is a pulsed power generator designed to deliver a 1 MA, 250 ns risetime current pulse into a dense plasma load. The main novel feature of this generator is the two auxiliary transmission lines which transmit the energy not absorbed by the load, reflect it at the open end of the line and deliver it to the load when the energy from the main lines is decreasing. With the auxiliary lines an increase of 30% on the current as well as a decrease of the voltage at the load is obtained. To date Llampuedken has been operated up to the 400 kA level, into both short circuit and plasma loads. Details of actual performance of the pulse power generator are presented and compared with simulations

  6. Isolation of human anti-serum albumin Fab antibodies with an extended serum-half life.

    Science.gov (United States)

    Kang, Hyeon-Ju; Kim, Hye-Jin; Cha, Sang-Hoon

    2016-01-01

    The serum albumin (SA) has been exploited to generate long-acting biotherapeutics by taking advantage of the FcRn-mediated recycling mechanism in a direct or an indirect way. Since Fab fragments have been proven to be clinically safe for human usage, we assumed that human anti-SA Fab antibodies could have a great potential as a carrier molecule to extend the serum half-life of therapeutic proteins. We, herein, had attempted to isolate anti-SA Fab antibodies from HuDVFab-8L antibody library via a phage display technology, and identified eight discrete human Fab antibodies. One of the Fab antibodies, SL335, showed the strongest binding reactivity to human SA with nM range of affinity at both pH 6 and pH 7.4, and cross-reacted to SAs from various species including rat, mouse, canine and monkey. The in vivo pharmacokinetic assay using a rat model indicated that SL335 has approximately 10 fold longer serum half-life and 26 to 44-fold increase in AUC0 → ∞ compared to the negative control Fab molecule in both intravenous and subcutaneous administrations. Knowing that Fabs have proven to be safe in clinics for a long time, SL335 seems to have a great potential in generating long-acting protein drugs by tagging effector molecules with either chemical conjugation or genetic fusion. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Preliminary measurements of the 87Rb half-life by means of the needle counter

    International Nuclear Information System (INIS)

    Zastawny, A.; Rabsztyn, B.

    1989-01-01

    In order to test the detector and to obtain the experience before starting the exact measurements, the measurements of 87 Rb half-life have been made. RbNO 3 produced by Merck was used to prepare the samples. The samples were prepared by evaporation of RbNO 3 water solution on an aluminium foil of 2,9 mg/cm 2 . The water solutions were changed in the range from (3286,4±1,8) x 10 -6 to (480,85±0,3) x 10 -6 . The background of the aluminium foil was equal to (0,117±0,007) cpm. In other measurements the back-scattering effect of 87 Rb beta rays on the aluminium foil amounted to 4%, as the measurements were performed in the 2π geometry. The diameters of samples were about 10 mm. The specific radioactivities of samples were measured versus the surface changed in the range (60-320) μg/cm 2 . The extrapolated value of the half-life, corrected for the chemical purity of the compound (as declared by the manufacterer) is equal to (4,86±0,1) x 10 10 years. This value is in good agreement with commonly accepted value of 4,88 x 10 10 years and with another last measurements. 10 refs., 1 fig., 2 tabs. (author)

  8. High-precision half-life measurements for the superallowed Fermi β+ emitter 14O

    Science.gov (United States)

    Laffoley, A. T.; Svensson, C. E.; Andreoiu, C.; Austin, R. A. E.; Ball, G. C.; Blank, B.; Bouzomita, H.; Cross, D. S.; Diaz Varela, A.; Dunlop, R.; Finlay, P.; Garnsworthy, A. B.; Garrett, P. E.; Giovinazzo, J.; Grinyer, G. F.; Hackman, G.; Hadinia, B.; Jamieson, D. S.; Ketelhut, S.; Leach, K. G.; Leslie, J. R.; Tardiff, E.; Thomas, J. C.; Unsworth, C.

    2013-07-01

    The half-life of the superallowed Fermi β+ emitter 14O has been determined via simultaneous direct β and γ counting experiments at TRIUMF's Isotope Separator and Accelerator (ISAC) facility. A γ-ray counting measurement was performed by detecting the 2312.6-keV γ rays emitted from an excited state of the daughter 14N following the implantation of samples at the center of the 8π γ-ray spectrometer, a spherical array of 20 high-purity germanium (HPGe) detectors. A simultaneous β counting experiment was performed using a fast plastic scintillator positioned behind the implantation site with a solid angle coverage of ˜20%. The results, T1/2(β)=70.610±0.030s and T1/2(γ)=70.632±0.094s, form a consistent set and, together with eight previous measurements, establish a new average for the 14O half-life of T1/2=70.619±0.011s with a reduced χ2 of 0.99.

  9. A new simplified allometric approach for predicting the biological half-life of radionuclides in reptiles

    International Nuclear Information System (INIS)

    Beresford, N.A.; Wood, M.D.

    2014-01-01

    A major source of uncertainty in the estimation of radiation dose to wildlife is the prediction of internal radionuclide activity concentrations. Allometric (mass-dependent) relationships describing biological half-life (T 1/2b ) of radionuclides in organisms can be used to predict organism activity concentrations. The establishment of allometric expressions requires experimental data which are often lacking. An approach to predict the T 1/2b in homeothermic vertebrates has recently been proposed. In this paper we have adapted this to be applicable to reptiles. For Cs, Ra and Sr, over a mass range of 0.02–1.5 kg, resultant predictions were generally within a factor of 6 of reported values demonstrating that the approach can be used when measured T 1/2b data are lacking. However, the effect of mass on reptilian radionuclide T 1/2b is minimal. If sufficient measured data are available for a given radionuclide then it is likely that these would give a reasonable estimate of T 1/2b in any reptile species. - Highlights: • An allometric approach to predict radionuclide T 1/2b values in reptiles is derived. • Predictions are generally within a factor of six of measured values. • Radionuclide biological half-life is in-effect mass independent

  10. Half-life data--a critical review of TECDOC-619 update

    International Nuclear Information System (INIS)

    Woods, M.J.; Collins, S.M.

    2004-01-01

    An accurate knowledge of selected nuclear decay data is critical to a wide range of processes involving radionuclides. An IAEA publication in 1991 was dedicated to the evaluation of half-lives and specific gamma-ray emission probabilities for 39 selected radionuclides considered to be important for detector efficiency calibrations. A new exercise was initiated in December 1998 to update this previous evaluation and to include a number of new radionuclides of interest; 62 radionuclides were considered along with specific parent-daughter combinations (to give a total of 64 radionuclides). That work is now being completed and a new set of recommended data is being prepared for publication. A critical comparison of the 1991 and 2003 half-life data suggests that there has not been any significant improvement in the accuracy of the recommended data. The possible reasons for this situation are discussed together with the evaluation procedure and the quality of the available data. Proposals are made for concerted actions that could lead to a significant improvement in these recommended half-life data

  11. Estimating the biological half-life for radionuclides in homoeothermic vertebrates: a simplified allometric approach

    Energy Technology Data Exchange (ETDEWEB)

    Beresford, N.A. [Lancaster Environment Centre, NERC Centre for Ecology and Hydrology, Lancaster (United Kingdom); Vives i Batlle, J. [Belgian Nuclear Research Centre, Mol (Belgium)

    2013-11-15

    The application of allometric, or mass-dependent, relationships within radioecology has increased with the evolution of models to predict the exposure of organisms other than man. Allometry presents a method of addressing the lack of empirical data on radionuclide transfer and metabolism for the many radionuclide-species combinations which may need to be considered. However, sufficient data across a range of species with different masses are required to establish allometric relationships and this is not always available. Here, an alternative allometric approach to predict the biological half-life of radionuclides in homoeothermic vertebrates which does not require such data is derived. Biological half-life values are predicted for four radionuclides and compared to available data for a range of species. All predictions were within a factor of five of the observed values when the model was parameterised appropriate to the feeding strategy of each species. This is an encouraging level of agreement given that the allometric models are intended to provide broad approximations rather than exact values. However, reasons why some radionuclides deviate from what would be anticipated from Kleiber's law need to be determined to allow a more complete exploitation of the potential of allometric extrapolation within radioecological models. (orig.)

  12. HALO--a Java framework for precise transcript half-life determination.

    Science.gov (United States)

    Friedel, Caroline C; Kaufmann, Stefanie; Dölken, Lars; Zimmer, Ralf

    2010-05-01

    Recent improvements in experimental technologies now allow measurements of de novo transcription and/or RNA decay at whole transcriptome level and determination of precise transcript half-lives. Such transcript half-lives provide important insights into the regulation of biological processes and the relative contributions of RNA decay and de novo transcription to differential gene expression. In this article, we present HALO (Half-life Organizer), the first software for the precise determination of transcript half-lives from measurements of RNA de novo transcription or decay determined with microarrays or RNA-seq. In addition, methods for quality control, filtering and normalization are supplied. HALO provides a graphical user interface, command-line tools and a well-documented Java application programming interface (API). Thus, it can be used both by biologists to determine transcript half-lives fast and reliably with the provided user interfaces as well as software developers integrating transcript half-life analysis into other gene expression profiling pipelines. Source code, executables and documentation are available at http://www.bio.ifi.lmu.de/software/halo.

  13. Increased half-life and enhanced potency of Fc-modified human PCSK9 monoclonal antibodies in primates.

    Directory of Open Access Journals (Sweden)

    Yijun Shen

    Full Text Available Blocking proprotein convertase subtilisin kexin type 9 (PCSK9 binding to low-density lipoprotein receptor (LDLR can profoundly lower plasma LDL levels. Two anti-PCKS9 monoclonal antibodies (mAbs, alirocumab and evolocumab, were approved by the FDA in 2015. The recommended dose is 75 mg to 150 mg every two weeks for alirocumab and 140mg every two weeks or 420 mg once a month for evolocumab. This study attempted to improve the pharmacokinetic properties of F0016A, an IgG1 anti-PCKS9 mAb, to generate biologically superior molecules. We engineered several variants with two or three amino acid substitutions in the Fc fragment based on prior knowledge. The Fc-modified mAbs exhibited increased binding to FcRn, resulting in prolonged serum half-life and enhanced efficacy in vivo. These results demonstrate that Fc-modified anti-PCKS9 antibodies may enable less frequent or lower dosing of antibodies by improved recycling into the blood.

  14. Half-Life of Sulfonylureas in HNF1A and HNF4A Human MODY Patients is not Prolonged as Suggested by the Mouse Hnf1a(-/-) Model.

    Science.gov (United States)

    Urbanova, Jana; Andel, Michal; Potockova, Jana; Klima, Josef; Macek, Jan; Ptacek, Pavel; Mat'oska, Vaclav; Kumstyrova, Tereza; Heneberg, Petr

    2015-01-01

    Sulfonylurea derivatives are widely used for clinical treatment of human subjects with Maturity Onset Diabetes of the Young (MODY) caused by mutations in HNF-1α or HNF-4α despite the mechanism leading to their hypersensitivity is incompletely understood. In Hnf1a(-/-) mice, serum concentrations and half-life of sulfonylurea derivatives are strongly increased. We thus hypothesized that reduced sulfonylurea derivatives clearance stands behind their therapeutic potential in human HNF1A/HNF4A MODY subjects. Single doses of 3 mg glipizide and 5 mg glibenclamide/glyburide were administered sequentially to seven HNF1A/HNF4A MODY subjects and six control individuals matched for their age, BMI and CYP2C9 genotype. Pharmacokinetic (plasma concentration levels, Cmax, tmax, t1/2, AUC) and pharmacodynamic parameters (glycemia, C-peptide and insulin plasma levels) were followed for 24 hours after drug administration. We provide the first evidence on the pharmacokinetics and pharmacodynamics of sulfonylurea derivatives in human MODY subjects. The half-life of glipizide did not change, and reached 3.8±0.7 and 3.7±1.8 h in the MODY and control subjects, respectively. The half-life of glibenclamide was increased only in some MODY subjects (t1/2 9.5±6.7 and 5.0±1.4 h, respectively). Importantly, the intra- individual responses of MODY (but control) subjects to glipizide and glibenclamide treatment were highly correlated. With regards to pharmacodynamics, we observed a differential response of control but not MODY subjects to the doses of glipizide and glibenclamide applied. We rejected the hypothesis that all human MODY-associated mutations in HNF1A / HNF4A induce changes in the pharmacokinetics of sulfonylureas in humans analogically to the Hnf1a(-/-) mouse model.

  15. High-precision half-life determination for 21Na using a 4 π gas-proportional counter

    Science.gov (United States)

    Finlay, P.; Laffoley, A. T.; Ball, G. C.; Bender, P. C.; Dunlop, M. R.; Dunlop, R.; Hackman, G.; Leslie, J. R.; MacLean, A. D.; Miller, D.; Moukaddam, M.; Olaizola, B.; Severijns, N.; Smith, J. K.; Southall, D.; Svensson, C. E.

    2017-08-01

    A high-precision half-life measurement for the superallowed β+ transition between the isospin T =1 /2 mirror nuclei 21Na and 21Ne has been performed at the TRIUMF-ISAC radioactive ion beam facility yielding T1 /2=22.4506 (33 ) s, a result that is a factor of 4 more precise than the previous world-average half-life for 21Na and represents the single most precisely determined half-life for a transition between mirror nuclei to date. The contribution to the uncertainty in the 21Na F tmirror value due to the half-life is now reduced to the level of the nuclear-structure-dependent theoretical corrections, leaving the branching ratio as the dominant experimental uncertainty.

  16. Study of the Bs meson and measurement of its half-life with the ALEPH detector

    International Nuclear Information System (INIS)

    Duarte, H.

    1994-01-01

    The B s 0 meson is the bound state of a quark anti-quark pair made up of a beauty particle and a strange particle. In the first chapter we review different experimental results leading to the existence of B S 0 meson and we draw the theoretical framework of the concept of beauty particles. The second chapter deals with the probability of the formation of a meson containing a strange quark during the fragmentation. This chapter also contains a re-analysis of the whole data constraining the mixing parameter B s 0 -B s 0 -bar. The relevancy of the analysis relies on the assumption that the B s 0 meson decays only into one D s , one lepton and one neutrino. The ALEPH detector is described in chapter 3, this four-pi, multi-particle detector is installed on the e + e - LEP (Large Electron Positron Collider). The signature selected for the measurement of the half-life is the combination of one D s in the decay modes: φπ, K *0 K with a lepton having opposite charge. This measurement implies the knowledge of the B s 0 momentum and of its flight length. In order to assess the momentum of the neutrino, a technique of measuring missing energy is presented in the chapter 4. The selection of B s 0 events is detailed in the chapter 5. A cutting limit on the energy of B s 0 based on the missing energy is used to deduce the production rate of B s 0 . In the chapter 6 we present the measurement of the half-life of B s 0 , the method used for the reconstruction of decay vertices and of the event main vertex is detailed. The validity of the method has been tested on Monte-Carlo simulations. The final result concerning the measurement of the half-life is: τ(B s )=[1.92(+0.45-0.35)±0.04] ps [fr

  17. Going Beyond the Binary : The body, Sexuality and Identity in Shelley Jackson’s Half Life: a novel

    OpenAIRE

    Liu, Linjing

    2012-01-01

    The thesis focuses on Shelley Jackson’s Half Life: a Novel with efforts directed towards a literary interpretation considering relevant issues within the context of gender and feminist theory. The argument rests upon four basic units: the theoretical framework at the outset, the question of the body next, thirdly an investigation of sexuality, and finally a consideration of identity. In Jackson’s Half Life: a Novel the non-dualist thinking underlies a deliberate play of dualism. To go beyond ...

  18. ORIGEN-S Decay Data Library and Half-Life Uncertainties

    International Nuclear Information System (INIS)

    Hermann, O.W.

    1998-01-01

    The results of an extensive update of the decay data of the ORIGEN-S library are presented in this report. The updated decay data were provided for both the ORIGEN-S and ORIGEN2 libraries in the same project. A complete edit of the decay data plus the available half-life uncertainties are included in Appendix A. A detailed description of the types of data contained in the library, the format of the library, and the data sources are also presented. Approximately 24% of the library nuclides are stable, 66% were updated from ENDF/B-VI, about 8% were updated from ENSDF, and the remaining 2% were not updated. Appendix B presents a listing of percentage changes in decay heat from the old to the updated library for all nuclides containing a difference exceeding 1% in any parameter

  19. Half-life distribution table of radioactive nuclei; Table de distribution des periodes des noyaux radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Gugenberger, P [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1954-07-01

    This table allows to identify an element if its period is known. Data for this table were taken from the half-life values adopted by Hollander, PERLMAN and SEABORG (Rev. mod. Phys., 1953, 22 number 2). Moreover for each nucleus, the mass number, the charge number and the type of decay are given in the table. (author) [French] Cette table permet l'identification d'un element dont la periode est connue. Elle a ete etablie en utilisant les valeurs des periodes donnees par HOLLANDER, PERLMAN et SEABORG dans Rev. mod. Phys., 1953, 25 numero 2. On y trouve en outre, pour chaque nuclide, les caracteristiques suivantes: Z, A, modes de desintegration. (auteur)

  20. Development of CANDLES low background HPGe detector and half-life measurement of 180Tam

    Science.gov (United States)

    Chan, W. M.; Kishimoto, T.; Umehara, S.; Matsuoka, K.; Suzuki, K.; Yoshida, S.; Nakajima, K.; Iida, T.; Fushimi, K.; Nomachi, M.; Ogawa, I.; Tamagawa, Y.; Hazama, R.; Takemoto, Y.; Nakatani, N.; Takihira, Y.; Tozawa, M.; Kakubata, H.; Trang, V. T. T.; Ohata, T.; Tetsuno, K.; Maeda, T.; Khai, B. T.; Li, X. L.; Batpurev, T.

    2018-01-01

    A low background HPGe detector system was developed at CANDLES Experimental Hall for multipurpose use. Various low background techniques were employed, including hermatic shield design, radon gas suppression, and background reduction analysis. A new pulse shape discrimination (PSD) method was specially created for coaxial Ge detector. Using this PSD method, microphonics noise and background event at low energy region less than 200 keV can be rejected effectively. Monte Carlo simulation by GEANT4 was performed to acquire the detection efficiency and study the interaction of gamma-rays with detector system. For rare decay measurement, the detector was utilized to detect the nature's most stable isomer tantalum-180m (180Tam) decay. Two phases of tantalum physics run were completed with total livetime of 358.2 days, which Phase II has upgraded shield configuration. The world most stringent half-life limit of 180Tam has been successfully achieved.

  1. Half-life of each dioxin and PCB congener in the human body

    Energy Technology Data Exchange (ETDEWEB)

    Ogura, Isamura [National Institute of Advanced Industrial Science and Technology, Tsukuba (Japan)

    2004-09-15

    It is well known that dioxin and PCB congeners accumulate in the human body. For assessing their toxicological risk, it is important to know the half-life of each congener in the human body. This study summarizes the overall half-lives of congeners in humans as reported in the literature, and compares them with the half-lives due to fecal and sebum excretions, as estimated by data on the concentrations of congeners in feces and sebum in the literature. In addition, the overall half-lives of congeners for the general Japanese population were estimated from the data on dietary intakes and concentrations in the human body reported by the municipalities.

  2. The beta(+) decay and cosmic-ray half-life of Mn-54

    Science.gov (United States)

    Dacruz, M. T. F.; Norman, E. B.; Chan, Y. D.; Garcia, A.; Larimer, R. M.; Lesko, K. T.; Stokstad, R. G.; Wietfeldt, F. E.

    1993-03-01

    We performed a search for the beta(+) branch of Mn-54 decay. As a cosmic ray, Mn-54, deprived of its atomic electrons, can decay only via beta(+) and beta(-) decay, with a half-life of the order of 106 yr. This turns Mn-54 into a suitable cosmic chronometer for the study of cosmic-ray confinement times. We searched for coincident back-to-back 511-keV gamma-rays using two germanium detectors inside a Nal(Tl) annulus. An upper limit of 2 x 10-8 was found for the beta(+) decay branch, corresponding to a lower limit of 13.7 for the log ft value.

  3. Precision measurement of the half-life of $^{109}$In in large and small lattice environments

    CERN Multimedia

    We propose to undertake high precision measurements of the half-life of $^{109}$In in large and small lattice environments to study the effect of compression on the electron capture nuclear decay rate. Such studies are of general interest having implications in many areas ranging from astrophysics to geophysics. At present, very little data is available on the change of electron capture decay rate under compression and the available data seems to indicate that the observed increase of the electron capture decay rate under compression is much greater than the predictions of the best available density functional calculations as obtained from TB-LMTO or WIEN2K codes. The proposed experiment should generate more data thus clarifying the experimental situation.

  4. Half-life distribution table of radioactive nuclei; Table de distribution des periodes des noyaux radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Gugenberger, P. [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1954-07-01

    This table allows to identify an element if its period is known. Data for this table were taken from the half-life values adopted by Hollander, PERLMAN and SEABORG (Rev. mod. Phys., 1953, 22 number 2). Moreover for each nucleus, the mass number, the charge number and the type of decay are given in the table. (author) [French] Cette table permet l'identification d'un element dont la periode est connue. Elle a ete etablie en utilisant les valeurs des periodes donnees par HOLLANDER, PERLMAN et SEABORG dans Rev. mod. Phys., 1953, 25 numero 2. On y trouve en outre, pour chaque nuclide, les caracteristiques suivantes: Z, A, modes de desintegration. (auteur)

  5. Development of a time-variable nuclear pulser for half life measurements

    International Nuclear Information System (INIS)

    Zahn, Guilherme S.; Domienikan, Claudio; Carvalhaes, Roberto P. M.; Genezini, Frederico A.

    2013-01-01

    In this work a time-variable pulser system with an exponentially-decaying pulse frequency is presented, which was developed using the low-cost, open-source Arduino microcontroler plataform. In this system, the microcontroller produces a TTL signal in the selected rate and a pulse shaper board adjusts it to be entered in an amplifier as a conventional pulser signal; both the decay constant and the initial pulse rate can be adjusted using a user-friendly control software, and the pulse amplitude can be adjusted using a potentiometer in the pulse shaper board. The pulser was tested using several combinations of initial pulse rate and decay constant, and the results show that the system is stable and reliable, and is suitable to be used in half-life measurements.

  6. Development of a time-variable nuclear pulser for half life measurements

    Energy Technology Data Exchange (ETDEWEB)

    Zahn, Guilherme S.; Domienikan, Claudio; Carvalhaes, Roberto P. M.; Genezini, Frederico A. [Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP. P.O. Box 11049, Sao Paulo, 05422-970 (Brazil)

    2013-05-06

    In this work a time-variable pulser system with an exponentially-decaying pulse frequency is presented, which was developed using the low-cost, open-source Arduino microcontroler plataform. In this system, the microcontroller produces a TTL signal in the selected rate and a pulse shaper board adjusts it to be entered in an amplifier as a conventional pulser signal; both the decay constant and the initial pulse rate can be adjusted using a user-friendly control software, and the pulse amplitude can be adjusted using a potentiometer in the pulse shaper board. The pulser was tested using several combinations of initial pulse rate and decay constant, and the results show that the system is stable and reliable, and is suitable to be used in half-life measurements.

  7. Biological half-life of iodine in adults with intact thyroid function and in athyreotic persons

    Energy Technology Data Exchange (ETDEWEB)

    Kramer, G.H.; Hauck, B.M.; Chamberlain, M.J

    2002-07-01

    A joint project between the Human Monitoring Laboratory (HML) and the Ottawa Hospital has measured the retention of {sup 131}I in patients who have received the radioiodine diagnostically. Thirty-nine subjects with intact thyroid glands and nine athyreotic subjects were measured in the HML's whole-body/thyroid counter to determine the retention of {sup 131}I following its medical administration. The average biological half-life of {sup 131}I in 26 euthyroid subjects was found to be 66.1{+-}6.3 days which may be statistically significantly lower than the ICRP recommended value of 80 days. Nine hyperthyroid patients had a mean biological half-life of 38.2{+-}8.6 days and in three hypothyroid patients the corresponding value was 29.3{+-}8.8 days. Thyroid {sup 131}I uptake was measured in a conventional clinical fashion at the Ottawa Hospital Civic campus 24 h after oral administration of the radioiodine using a collimated thick sodium iodide detector placed over the neck arteriorly. Measured values were 0.144{+-}0.009, 0.314{+-}0.035 and 0.045{+-}0.010 of the administered dose in euthyroid, hyperthyroid and hypothyroid patients respectively. The euthyroid range at the hospital is 0.06-0.22. Uptake was significantly lower for the euthyroid group than the ICRP value of 0.3. The radioiodine retention in athyreotic subjects followed a two compartment model with biological half-lives of 1.0{+-}0.2 days and 18.4{+-}1.1. days. (author)

  8. Simulation of intense short-pulse laser-plasma interaction

    International Nuclear Information System (INIS)

    Yamagiwa, Mitsuru

    2000-01-01

    We have completed the massive parallelization of a 2-dimensional giga-particle code and have achieved a 530-fold acceleration rate with 512 processing elements (PE's). Using this we have implemented a simulation of the interaction of a solid thin film and a high intensity laser and have discovered a phenomenon in which high quality short pulses from the far ultraviolet to soft X-rays are generated at the back surface of the thin layer. We have also introduced the atomic process database code (Hullac) and have the possibility for high precision simulations of X-ray laser radiation. With respect to laser acceleration we have the possibility to quantitatively evaluate relativistic self-focusing assumed to occur in higher intensity fields. Ion acceleration from a solid target and an underdense plasma irradiated by an intense and an ultra intense laser, respectively, has also been studied by particle-in-cell (PIC) simulations. (author)

  9. CYP2C8 activity recovers within 96 hours after gemfibrozil dosing: estimation of CYP2C8 half-life using repaglinide as an in vivo probe.

    Science.gov (United States)

    Backman, Janne T; Honkalammi, Johanna; Neuvonen, Mikko; Kurkinen, Kaisa J; Tornio, Aleksi; Niemi, Mikko; Neuvonen, Pertti J

    2009-12-01

    Gemfibrozil 1-O-beta-glucuronide is a mechanism-based inhibitor of cytochrome P450 2C8. We studied the recovery of CYP2C8 activity after discontinuation of gemfibrozil treatment using repaglinide as a probe drug, to estimate the in vivo turnover half-life of CYP2C8. In a randomized five-phase crossover study, nine healthy volunteers ingested 0.25 mg of repaglinide alone or after different time intervals after a 3-day treatment with 600 mg of gemfibrozil twice daily. The area under the plasma concentration-time curve (AUC) from time 0 to infinity of repaglinide was 7.6-, 2.9-, 1.4- and 1.0-fold compared with the control phase when it was administered 1, 24, 48, or 96 h after the last gemfibrozil dose, respectively (P gemfibrozil). Thus, a strong CYP2C8 inhibitory effect persisted even after gemfibrozil and gemfibrozil 1-O-beta-glucuronide concentrations had decreased to less than 1% of their maximum (24-h dosing interval). In addition, the metabolite to repaglinide AUC ratios indicated that significant (P gemfibrozil administration. Based on the recovery of repaglinide oral clearance, the in vivo turnover half-life of CYP2C8 was estimated to average 22 +/- 6 h (mean +/- S.D.). In summary, CYP2C8 activity is recovered gradually during days 1 to 4 after gemfibrozil discontinuation, which should be considered when CYP2C8 substrate dosing is planned. The estimated CYP2C8 half-life will be useful for in vitro-in vivo extrapolations of drug-drug interactions involving induction or mechanism-based inhibition of CYP2C8.

  10. Pre-Clinical Intravenous Serum Pharmacokinetics of Albumin Binding and Non-Half-Life Extended Nanobodies®

    Directory of Open Access Journals (Sweden)

    Sven Hoefman

    2015-07-01

    Full Text Available Nanobodies are antigen-binding, single variable domain proteins derived from naturally-occurring, heavy chain only antibodies. They are highly soluble, stable, and can be linked to build multi-specific formats. Several Nanobodies are currently in clinical development in different therapeutic areas, for both chronic and acute applications. For the former, prolonged exposure is achieved by half-life extending moieties that target endogenous albumin, while for the latter, non-half-life extended constructs are preferable. To demonstrate the general pharmacokinetic behavior of both formats, serum levels of seven intravenously administered Nanobodies were analyzed in cynomolgus monkeys, mice or rabbits. In monkeys, the total clearance of a monomeric irrelevant Nanobody was rapid (2.0 mL/(min*kg and approximated the species glomerular filtration rate, indirectly suggesting that the Nanobody was mainly eliminated via the kidneys. When linked to an anti-albumin Nanobody, a 376-fold decrease in clearance was observed, resulting in a terminal half-life of 4.9 days, corresponding to the expected species albumin half-life. Similar conclusions were drawn for (non- half-life extended mono-, bi- and trimeric Nanobodies in mice or rabbits, suggesting that these kinetic principles apply across species. Applying this knowledge to species translation and study design is crucial for successful pre-clinical development of novel therapeutic Nanobody candidates.

  11. Extending the half-life of a fab fragment through generation of a humanized anti-human serum albumin Fv domain: An investigation into the correlation between affinity and serum half-life.

    Science.gov (United States)

    Adams, Ralph; Griffin, Laura; Compson, Joanne E; Jairaj, Mark; Baker, Terry; Ceska, Tom; West, Shauna; Zaccheo, Oliver; Davé, Emma; Lawson, Alastair Dg; Humphreys, David P; Heywood, Sam

    2016-10-01

    We generated an anti-albumin antibody, CA645, to link its Fv domain to an antigen-binding fragment (Fab), thereby extending the serum half-life of the Fab. CA645 was demonstrated to bind human, cynomolgus, and mouse serum albumin with similar affinity (1-7 nM), and to bind human serum albumin (HSA) when it is in complex with common known ligands. Importantly for half-life extension, CA645 binds HSA with similar affinity within the physiologically relevant range of pH 5.0 - pH 7.4, and does not have a deleterious effect on the binding of HSA to neonatal Fc receptor (FcRn). A crystal structure of humanized CA645 Fab in complex with HSA was solved and showed that CA645 Fab binds to domain II of HSA. Superimposition with the crystal structure of FcRn bound to HSA confirmed that CA645 does not block HSA binding to FcRn. In mice, the serum half-life of humanized CA645 Fab is 84.2 h. This is a significant extension in comparison with Fab variant. The Fab-HSA structure was used to design a series of mutants with reduced affinity to investigate the correlation between the affinity for albumin and serum half-life. Reduction in the affinity for MSA by 144-fold from 2.2 nM to 316 nM had no effect on serum half-life. Strikingly, despite a reduction in affinity to 62 µM, an extension in serum half-life of 26.4 h was still obtained. CA645 Fab and the CA645 Fab-HSA complex have been deposited in the Protein Data Bank (PDB) with accession codes, 5FUZ and 5FUO, respectively.

  12. Ecological half-life of 137Cs in plants associated with a contaminated stream

    International Nuclear Information System (INIS)

    Peles, John D.; Smith, Michael H.; Lehr Brisbin, I.

    2002-01-01

    Ecological half-life (T e ) is a useful measure for studying the long-term decline of contaminants, such as radionuclides, in natural systems. The current investigation determined levels of radiocesium ( 137 Cs) in two aquatic (Polygonum punctatum, Sagittaria latifolia) and three terrestrial (Alnus serrulata, Myrica cerifera, Salix nigra) plant species from a contaminated stream and floodplain on the U.S. Department of Energy's Savannah River Site. Current 137 Cs levels in plants were used in conjunction with historical data to determine T e of 137 Cs in each species. Median concentrations of 137 Cs were highest in S. latifolia (0.84 Bq g -1 ) and lowest in M. cerifera (0.10 Bq g -1 ). T e 's ranged from 4.85 yr in M. cerifera to 8.35 yr in S. nigra, both terrestrial species. T e 's for all aquatic (6.30 yr) and all terrestrial (5.87) species combined were very similar. The T e 's of the two aquatic primary producers (P. punctatum and S. latifolia) in the Steel Creek ecosystem were somewhat longer than T e values previously reported for some consumers from this ecosystem

  13. Prediction of thyroidal 131I effective half-life in patients with Graves' disease.

    Science.gov (United States)

    Zhang, Ruiguo; Zhang, Guizhi; Wang, Renfei; Tan, Jian; He, Yajing; Meng, Zhaowei

    2017-10-06

    Calculation of effective thyroidal half-life (Teff) of iodine-131( 131 I) is cumbersome and tedious. The aim of this study was to investigate factors that could be used to predict Teff and to develop a Teff prediction model in Graves' disease patients. A total of 256 patients with GD were involved in this study. We investigated the influences of age, gender, disease duration, thyroid weight, antithyroid drugs, antithyroid drugs discontinuation period (ADP), thyroid function indexes, thyroid autoantibodies, thyroid-stimulating hormone receptor antibody (TRAb) level and radioactive iodine uptake (RAIU) values before 131 I therapy on Teff, applying univariate and multivariate analyses. Teff correlated negatively with thyroid peroxidase antibody, TRAb and thyroid weight, as well as positively with 24-hour, 48-hour, and 72-hour RAIU. Additionally, a longer ADP (especially≥ 14d) or without antithyroid drugs before 131 I therapy led to a longer Teff. Stepwise multiple linear regression analysis showed that 24-hour and 72-hour RAIU were statistically significant predictors of Teff ( P Graves' disease, with high prediction accuracy.

  14. Kinetic modeling and half life study on bioremediation of crude oil dispersed by Corexit 9500

    International Nuclear Information System (INIS)

    Zahed, Mohammad Ali; Aziz, Hamidi Abdul; Isa, Mohamed Hasnain; Mohajeri, Leila; Mohajeri, Soraya; Kutty, Shamsul Rahman Mohamed

    2011-01-01

    Hydrocarbon pollution in marine ecosystems occurs mainly by accidental oil spills, deliberate discharge of ballast waters from oil tankers and bilge waste discharges; causing site pollution and serious adverse effects on aquatic environments as well as human health. A large number of petroleum hydrocarbons are biodegradable, thus bioremediation has become an important method for the restoration of oil polluted areas. In this research, a series of natural attenuation, crude oil (CO) and dispersed crude oil (DCO) bioremediation experiments of artificially crude oil contaminated seawater was carried out. Bacterial consortiums were identified as Acinetobacter, Alcaligenes, Bacillus, Pseudomonas and Vibrio. First order kinetics described the biodegradation of crude oil. Under abiotic conditions, oil removal was 19.9% while a maximum of 31.8% total petroleum hydrocarbons (TPH) removal was obtained in natural attenuation experiment. All DCO bioreactors demonstrated higher and faster removal than CO bioreactors. Half life times were 28, 32, 38 and 58 days for DCO and 31, 40, 50 and 75 days for CO with oil concentrations of 100, 500, 1000 and 2000 mg/L, respectively. The effectiveness of Corexit 9500 dispersant was monitored in the 45 day study; the results indicated that it improved the crude oil biodegradation rate.

  15. $\\beta$-decay half-life of $^{70}$Kr a bridge nuclide for the rp-process beyond A = 70

    CERN Document Server

    Oinonen, M; Jokinen, A; Baumann, P; Didierjean, François; Huck, A; Knipper, A; Ramdhane, M; Walter, G; Van Duppen, P; Huyse, M; Marguier, G; Novikov, Yu N; Popov, A; Seliverstov, D M; Schatz, H

    2000-01-01

    The $\\beta$-decay half-life of $^{70}$Kr has been measured for the first time at the ISOLDE PSB Facility at CERN. Mass separated $^{70}$Kr ions were produced by 1 GeV proton induced spallation reactions in a Nb foil. The measured half-life is 57(21) ms. This value is consistent with the half-life calculated assuming a pure Fermi decay, but is clearly lower than the value used in a recent rp-process reaction flow calculation. The result shows that the reaction flow via two-proton-capture of $^{68}$Se is 2.5 times faster than previously calculated assuming an astrophysical temperature of 1.5 GK and a density of 10$^{6}$g/cm$^{3}$.

  16. Towards a measurement of the half-life of {sup 60}Fe for stellar and early Solar System models

    Energy Technology Data Exchange (ETDEWEB)

    Ostdiek, K.; Anderson, T. [University of Notre Dame, Notre Dame, IN 46556 (United States); Bauder, W. [University of Notre Dame, Notre Dame, IN 46556 (United States); Argonne National Laboratory, 9700 South Cass Avenue, Lemont, IL 60439 (United States); Bowers, M.; Collon, P. [University of Notre Dame, Notre Dame, IN 46556 (United States); Dressler, R. [Paul Scherrer Institute – Laboratory for Radiochemistry and Environmental Chemistry, 5232 Villigen (Switzerland); Greene, J. [Argonne National Laboratory, 9700 South Cass Avenue, Lemont, IL 60439 (United States); Kutschera, W. [Vienna Environmental Research Accelerator Laboratory, Waehringer Strasse 17, 1090 Vienna (Austria); Lu, W. [University of Notre Dame, Notre Dame, IN 46556 (United States); Paul, M. [Racah Institute of Physics, Hebrew University, Jerusalem 91904 (Israel); Robertson, D. [University of Notre Dame, Notre Dame, IN 46556 (United States); Schumann, D. [Paul Scherrer Institute – Laboratory for Radiochemistry and Environmental Chemistry, 5232 Villigen (Switzerland); Skulski, M. [University of Notre Dame, Notre Dame, IN 46556 (United States); Wallner, A. [The Australian National University, Canberra, ACT 0200 (Australia)

    2015-10-15

    Radioisotopes, produced in stars and ejected into the Interstellar Medium, are important for constraining stellar and early Solar System (ESS) models. In particular, the half-life of the radioisotope, {sup 60}Fe, can have an impact on calculations for the timing for ESS events, the distance to nearby Supernovae, and the brightness of individual, non-steady-state {sup 60}Fe gamma ray sources in the Galaxy. A half-life measurement has been undertaken at the University of Notre Dame and measurements of the {sup 60}Fe/{sup 56}Fe concentration of our samples using Accelerator Mass Spectrometry has begun. This result will be coupled with an activity measurement of the isomeric decay in {sup 60}Co, which is the decay product of {sup 60}Fe. Preliminary half-life estimates of (2.53 ± 0.24) × 10{sup 6} years seem to confirm the recent measurement by Rugel et al. (2009).

  17. New evaluation of alpha decay half-life of 190Pt isotope for the Pt-Os dating system

    International Nuclear Information System (INIS)

    Tavares, O.A.P.; Medeiros, E.L.; Terranova, M.L.

    2005-08-01

    A semiempirical model based on the quantum mechanical tunnelling mechanism of alpha emission from nuclei has been used to evaluate the half-life of the Pt isotopes. For the important naturally occurring 190 Pt isotope, the radiogenic parent in the 190 Pt → 186 Os dating system, the model yielded a half-life value of (3.7± 0.3) versus 10 11 y. This is comparable to (3.2±0.1) versus 10 11 y which was obtained in the last direct counting experiment to measure the alpha activity of 190 Pt (Tavares and Terranova, Rad. Measurem. 27 (1997) 19). A literature survey of available alpha decay half-life values for 190 Pt isotope is also reported. The significant discrepancies found between data obtained by direct counting, indirect geological methods and different calculation models are analysed and discussed. (author)

  18. Examination of the biological half-life and organ d;stribution of tritiated lysin-vasopressin in Brattleboro rats

    International Nuclear Information System (INIS)

    Laczi, F.; Laszlo, F.

    1980-01-01

    15 μCi tritiated lysin-vasopressin (spec. act. 3.5 Ci per mmol) was administered to control and Brattleboro rats, suffering from hereditary hypothalamic diabetes insipidus. The biological half-life and the distribution of the labelled compound in the different organs were determined. The biological half-life demonstrated no significant difference, however, the vasopressin content of the small intestine was higher in the Brattleboro rats. In the other organs no significant difference was found. It can be concluded that the hereditary diabetes insipidus is not due to faster elimination of circulating vasopressin. (L.E.)

  19. High-Precision Half-Life Measurements for the Superallowed Fermi β+ Emitters 14O and 18Ne

    Science.gov (United States)

    Laffoley, A. T.; Andreoiu, C.; Austin, R. A. E.; Ball, G. C.; Bender, P. C.; Bidaman, H.; Bildstein, V.; Blank, B.; Bouzomita, H.; Cross, D. S.; Deng, G.; Diaz Varela, A.; Dunlop, M. R.; Dunlop, R.; Finlay, P.; Garnsworthy, A. B.; Garrett, P.; Giovinazzo, J.; Grinyer, G. F.; Grinyer, J.; Hadinia, B.; Jamieson, D. S.; Jigmeddorj, B.; Ketelhut, S.; Kisliuk, D.; Leach, K. G.; Leslie, J. R.; MacLean, A.; Miller, D.; Mills, B.; Moukaddam, M.; Radich, A. J.; Rajabali, M. M.; Rand, E. T.; Svensson, C. E.; Tardiff, E.; Thomas, J. C.; Turko, J.; Voss, P.; Unsworth, C.

    High-precision half-life measurements, at the level of ±0.04%, for the superallowed Fermi emitters 14O and 18Ne have been performed at TRIUMF's Isotope Separator and Accelerator facility. Using 3 independent detector systems, a gas-proportional counter, a fast plastic scintillator, and a high-purity germanium array, a series of direct β and γ counting measurements were performed for each of the isotopes. In the case of 14O, these measurements were made to help resolve an existing discrepancy between detection methods, whereas for 18Ne the half-life precision has been improved in anticipation of forthcoming high-precision branching ratio measurements.

  20. High-precision half-life and branching-ratio measurements for superallowed Fermi β+ emitters at TRIUMF - ISAC

    Science.gov (United States)

    Laffoley, A. T.; Dunlop, R.; Finlay, P.; Grinyer, G. F.; Andreoiu, C.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Blank, B.; Bouzomita, H.; Chagnon-Lessard, S.; Chester, A.; Cross, D. S.; Demand, G.; Diaz Varela, A.; Djongolov, M.; Ettenauer, S.; Garnsworthy, A. B.; Garrett, P. E.; Giovinazzo, J.; Glister, J.; Green, K. L.; Hackman, G.; Hadinia, B.; Jamieson, D. S.; Ketelhut, S.; Leach, K. G.; Leslie, J. R.; Pearson, C. J.; Phillips, A. A.; Rand, E. T.; Starosta, K.; Sumithrarachchi, C. S.; Svensson, C. E.; Tardiff, E. R.; Thomas, J. C.; Towner, I. S.; Triambak, S.; Unsworth, C.; Williams, S. J.; Wong, J.; Yates, S. W.; Zganjar, E. F.

    2014-03-01

    A program of high-precision half-life and branching-ratio measurements for superallowed Fermi β emitters is being carried out at TRIUMF's Isotope Separator and Accelerator (ISAC) radioactive ion beam facility. Recent half-life measurements for the superallowed decays of 14O, 18Ne, and 26Alm, as well as branching-ratio measurements for 26Alm and 74Rb are reported. These results provide demanding tests of the Standard Model and the theoretical isospin symmetry breaking (ISB) corrections in superallowed Fermi β decays.

  1. Examination of the biological half-life and organ d; stribution of tritiated lysin-vasopressin in Brattleboro rats

    Energy Technology Data Exchange (ETDEWEB)

    Laczi, F; Laszlo, F [Szegedi Orvostudomanyi Egyetem Szeged (Hungary). 1. Belgyogyaszati Klinika; Keri, Gy; Teplan, I [Semmelweis Orvostudomanyi Egyetem, Budapest (Hungary)

    1980-04-01

    15 ..mu..Ci tritiated lysin-vasopressin (spec. act. 3.5 Ci per mmol) was administered to control and Brattleboro rats, suffering from hereditary hypothalamic diabetes insipidus. The biological half-life and the distribution of the labelled compound in the different organs were determined. The biological half-life demonstrated no significant difference, however, the vasopressin content of the small intestine was higher in the Brattleboro rats. In the other organs no significant difference was found. It can be concluded that the hereditary diabetes insipidus is not due to faster elimination of circulating vasopressin.

  2. Interaction of ultra-short ultra-intense laser pulses with under-dense plasmas

    International Nuclear Information System (INIS)

    Solodov, A.

    2000-12-01

    Different aspects of interaction of ultra-short ultra-intense laser pulses with underdense plasmas are studied analytically and numerically. These studies can be interesting for laser-driven electron acceleration in plasma, X-ray lasers, high-order harmonic generation, initial confinement fusion with fast ignition. For numerical simulations a fully-relativistic particle code WAKE was used, developed earlier at Ecole Polytechnique. It was modified during the work on the thesis in the part of simulation of ion motion, test electron motion, diagnostics for the field and plasma. The studies in the thesis cover the problems of photon acceleration in the plasma wake of a short intense laser pulse, phase velocity of the plasma wave in the Self-Modulated Laser Wake-Field Accelerator (SM LWFA), relativistic channeling of laser pulses with duration of the order of a plasma period, ion dynamics in the wake of a short intense laser pulse, plasma wave breaking. Simulation of three experiments on the laser pulse propagation in plasma and electron acceleration were performed. Among the main results of the thesis, it was found that reduction of the plasma wave phase velocity in the SM LWFA is crucial for electron acceleration, only if a plasma channel is used for the laser pulse guiding. Self-similar structures describing relativistic guiding of short laser pulses in plasmas were found and relativistic channeling of initially Gaussian laser pulses of a few plasma periods in duration was demonstrated. It was shown that ponderomotive force of a plasma wake excited by a short laser pulse forms a channel in plasma and plasma wave breaking in the channel was analyzed in detail. Effectiveness of electron acceleration by the laser field and plasma wave was compared and frequency shift of probe laser pulses by the plasma waves was found in conditions relevant to the current experiments. (author)

  3. Real-World Analysis of Dispensed IUs of Coagulation Factor IX and Resultant Expenditures in Hemophilia B Patients Receiving Standard Half-life Versus Extended Half-life Products and Those Switching from Standard Half-life to Extended Half-life Products.

    Science.gov (United States)

    Tortella, Bartholomew J; Alvir, José; McDonald, Margaret; Spurden, Dean; Fogarty, Patrick F; Chhabra, Amit; Pleil, Andreas M

    2018-01-24

    Hemophilia B requires replacement therapy with factor IX (FIX) coagulation products to treat and prevent bleeding episodes. A recently introduced extended half-life (EHL) recombinant FIX replacement product provided the opportunity to compare the amount of dispensed factor and expenditures for EHL treatment compared with a standard half-life (SHL) product. To determine factor international units (IUs) dispensed and expenditures associated with switching from nonacog alfa, the most commonly used SHL replacement product, to eftrenonacog alfa, an EHL FIX replacement product. Two U.S. claims databases were analyzed. A large national specialty pharmacy dispensation claims database was used to identify the number of IUs dispensed and monthly charges for all patients with hemophilia B from April 2015 to June 2016. Truven Health MarketScan Research Databases (January 2010-July 2016) were used to identify IUs and expenditures for patients with claims data for at least 3 months before and after switching from the SHL to the EHL product. Medians for IUs and expenditures are presented to accommodate for skewness of data distribution. The national specialty pharmacy database analysis included 296 patients with moderate or severe hemophilia B (233 on SHL; 94 on EHL). Median monthly factor dispensed was 11% lower (2,142 IU) in the EHL versus SHL cohort over the study period, while individual monthly reductions ranged from 32% to 47% (9,838 IU to 16,514 IU). Using the wholesale acquisition cost, the median per-patient monthly factor expenditures over the 15-month study period were 94% higher ($23,005) for the EHL than for the SHL product. Individual median monthly expenditure differences ranged from 15% ($6,562) to 49% ($19,624). In the Truven database, 14 patients switched from the SHL to the EHL product. The amount of factor dispensed was variable; in the 1-year period before and after the switch from the SHL to the EHL product, mean IUs dispensed decreased by 3,005 IU, while

  4. Biological Half-Life Measurements of Radioactive Strontium in Hormonal-Resistant Prostate Cancer Patients

    International Nuclear Information System (INIS)

    Haquin, G.; Riemer, T.; Kaniun, N.; Datz, H.; Yungreiss, Z.; Vexler, A.; Ben-Yosef, R.; Pelled, O.; German, U.; Marko, R.; Teshuva, A.; Kol, R.

    2004-01-01

    Therapy for metastatic bone pain in Hormonal-Resistant Prostate Cancer (HRPC) patients is performed by administering systemic radioisotope therapy [1]. The beta radiation emitted by the radioactive strontium 89 Sr [T 1/2 =50.5 d, E β (max)=1.49 MeV], an adequate radionuclide for this therapy procedure, irradiates the metastatic cells in the bone, producing the desired palliative effect. The beta disintegration of 89 Sr is followed by a low abundance (0.00945%) gamma ray with energy of 909 keV. The commercially available 89 Sr is in the form of Sr Cl and contains an impurity of less than 0.5% of 85 Sr [T 1/2 =64.8 d] ,which decays by electron capture, emitting gamma rays at 511 keV (95.71%). The radiation dose to the metastatic cells due to the gamma rays is negligible compared to the dose given by the beta radiation, assuming that the 89 Sr is concentrated at the metastatic bony lesions. Accurate information about retention and excretion of Sr in the patient's body will contribute to better evaluate the effectiveness of the treatment. he effective half-life of 89 Sr can be calculated either from Whole Body Counting (WBC) measurements or by measuring 85 Sr and/or 89 Sr in urine/blood. WBC measurements, using collimated HPGe detectors, allow the follow-up of 89 Sr and 85 Sr at different sites in the skeletal bones of the patient. Biological half-lives of Sr in different body sections measured by WBC and the correlation with excretion-rate-based biological half-lives are presented

  5. Carboxyhemoglobin half-life during hyperbaric oxygen in a patient with lung dysfunction: a case report.

    Science.gov (United States)

    Weaver, Lindell K; Deru, Kayla

    2017-01-01

    The carboxyhemoglobin half-life (COHb t1/2) during hyperbaric oxygen (HBO₂) is often quoted as 23 minutes, derived from the average of two adult male volunteers breathing HBO₂ at 3 atmospheres absolute (ATA). However, the mean COHb t1/2 of 12 male volunteer smokers was 26.3 minutes at 1.58 ATA and in 12 non-intubated carbon monoxide (CO) poisoned patients treated at 3 ATA, was 43 minutes. An 81-year old male, poisoned by an improperly ventilated natural gas heater, was intubated for coma, then treated with HBO₂. His PaO₂/FiO₂ = 283 from aspiration. His initial COHb was 34.4%, and 18 minutes before HBO₂, 5.9%. After a compression interval of 17 minutes, the COHb measured after 22 minutes at 3 ATA was 3.3%. By exponential decay, his COHb t1/2 before HBO₂ was 95 minutes. We estimate the range for COHb t1/2 during compression as 62-81 minutes and for the 3-ATA interval, 58 to 49 minutes, respectively. The mid-point estimate of COHb t1/2 at 3 ATA was 53 minutes. The COHb t1/2 we calculated is greater than previously reported, but longer in our patient possibly because of concomitant respiratory failure, lung dysfunction, and mechanical ventilation. The often-cited COHb t1/2 of 23 minutes, likely underestimates the actual COHb t1/2 in CO-poisoned patients, especially those with cardiopulmonary dysfunction.

  6. Biological half-life of bromide in the rat depends primarily on the magnitude of sodium intake

    Czech Academy of Sciences Publication Activity Database

    Pavelka, Stanislav; Babický, Arnošt; Vobecký, Miloslav

    2005-01-01

    Roč. 54, č. 6 (2005), s. 639-644 ISSN 0862-8408 Institutional research plan: CEZ:AV0Z50110509 Keywords : biological half-life * bromide * sodium Subject RIV: ED - Physiology Impact factor: 1.806, year: 2005

  7. High-precision half-life measurements of the T =1 /2 mirror β decays 17F and 33Cl

    Science.gov (United States)

    Grinyer, J.; Grinyer, G. F.; Babo, M.; Bouzomita, H.; Chauveau, P.; Delahaye, P.; Dubois, M.; Frigot, R.; Jardin, P.; Leboucher, C.; Maunoury, L.; Seiffert, C.; Thomas, J. C.; Traykov, E.

    2015-10-01

    Background: Measurements of the f t values for T =1 /2 mirror β+ decays offer a method to test the conserved vector current hypothesis and to determine Vud, the up-down matrix element of the Cabibbo-Kobayashi-Maskawa matrix. In most mirror decays used for these tests, uncertainties in the f t values are dominated by the uncertainties in the half-lives. Purpose: Two precision half-life measurements were performed for the T =1 /2 β+ emitters, 17F and 33Cl, in order to eliminate the half-life as the leading source of uncertainty in their f t values. Method: Half-lives of 17F and 33Cl were determined using β counting of implanted radioactive ion beam samples on a moving tape transport system at the Système de Production d'Ions Radioactifs Accélérés en Ligne low-energy identification station at the Grand Accélérateur National d'Ions Lourds. Results: The 17F half-life result, 64.347 (35) s, precise to ±0.05 % , is a factor of 5 times more precise than the previous world average. The half-life of 33Cl was determined to be 2.5038 (22) s. The current precision of ±0.09 % is nearly 2 times more precise compared to the previous world average. Conclusions: The precision achieved during the present measurements implies that the half-life no longer dominates the uncertainty of the f t values for both T =1 /2 mirror decays 17F and 33Cl.

  8. Ubiquitin-fusion as a strategy to modulate protein half-life: A3G antiviral activity revisited

    International Nuclear Information System (INIS)

    Cadima-Couto, Iris; Freitas-Vieira, Acilino; Nowarski, Roni; Britan-Rosich, Elena; Kotler, Moshe; Goncalves, Joao

    2009-01-01

    The human APOBEC3G (A3G) is a potent inhibitor of HIV-1 replication and its activity is suppressed by HIV-1 virion infectivity factor (Vif). Vif neutralizes A3G mainly by inducing its degradation in the proteasome and blocking its incorporation into HIV-1 virions. Assessing the time needed for A3G incorporation into virions is, therefore, important to determine how quickly Vif must act to induce its degradation. We show that modelling the intracellular half-life of A3G can induce its Vif-independent targeting to the ubiquitin-proteasome system. By using various amino acids (X) in a cleavable ubiquitin-X-A3G fusion, we demonstrate that the half-life (t1/2) of X-A3G can be manipulated. We show that A3G molecules with a half-life of 13 min are incorporated into virions, whereas those with a half-life shorter than 5 min were not. The amount of X-A3G incorporated into virions increases from 13 min (Phe-A3G) to 85 min (Asn-A3G) and remains constant after this time period. Interestingly, despite the presence of similar levels of Arg-A3G (t1/2 = 28 min) and Asp-A3G (t1/2 = 65 min) into HIV-1 Δvif virions, inhibition of viral infectivity was only evident in the presence of A3G proteins with a longer half-life (t1/2 ≥ 65 min).

  9. Effective Half-Life of Caesium-137 in Various Environmental Media at the Savannah River Site

    Energy Technology Data Exchange (ETDEWEB)

    Paller, M. H.; Jannik, G. T.; Baker, R. A.

    2014-05-01

    During the operational history of the Savannah River Site (SRS), many different radionuclides have been released from site facilities into the SRS environment. However, only a relatively small number of pathways, most importantly 137Cs in fish and deer, have contributed significantly to doses and risks to the public. The “effective” half-lives (Te) of 137Cs (which include both physical decay and environmental dispersion) in Savannah River floodplain soil and vegetation and in fish and white-tailed deer from the SRS were estimated using long-term monitoring data. For 1974–2011, the Tes of 137Cs in Savannah River floodplain soil and vegetation were 17.0 years (95% CI = 14.2–19.9) and 13.4 years (95% CI = 10.8–16.0), respectively. These Tes were greater than in a previous study that used data collected only through 2005 as a likely result of changes in the flood regime of the Savannah River. Field analyses of 137Cs concentrations in deer collected during yearly controlled hunts at the SRS indicated an overall Te of 15.9 years (95% CI = 12.3–19.6) for 1965–2011; however, the Te for 1990–2011 was significantly shorter (11.8 years, 95% CI = 4.8–18.8) due to an increase in the rate of 137Cs removal. The shortest Tes were for fish in SRS streams and the Savannah River (3.5–9.0 years), where dilution and dispersal resulted in rapid 137Cs removal. Long-term data show that Tes are significantly shorter than the physical half-life of 137Cs in the SRS environment but that they can change over time. Therefore, it is desirable have a long period of record for calculating Tes and risky to extrapolate Tes beyond this period unless the processes governing 137Cs removal are clearly understood.

  10. Physiologically based pharmacokinetics model for estimating urinary excretion of short half-life nuclides in nuclear medicine

    International Nuclear Information System (INIS)

    Akahane, K.; Kai, M.; Konishi, E.; Kusama, T.; Aoki, Y.

    1995-01-01

    The biokinetic model in ICRP 53 is used for calculating absorbed dose to each organ of a patient in nuclear medicine. The ICRP model is a simple compartment model based on human data; however, the model cannot produce the biokinetics of radiopharmaceuticals under various physiological conditions. On the other hand, a physiologically based pharmacokinetics model (PBPK model) can describe the flow of radiopharmaceuticals as a compartment model for any physiological conditions theoretically. The PBPK model was applied especially for the kidney-bladder dynamics, and similar results obtained compared with the ICRP model. This suggests the possibility of the PBPK model for predicting the biokinetics of radiopharmaceuticals under various physiological conditions. (Author)

  11. Study on the biological half-life and organ-distribution of tritiated lysine-vasopressin in Brattleboro rats

    International Nuclear Information System (INIS)

    Laczi, F.; Laszlo, F.A.; Keri, Gy.; Teplan, I.

    1980-01-01

    The biological half-life and organ-distribution of tritiated lysine-vasopressin were determined in R-Amsterdam rats, and in homozygous and heterozygous Brattleboro rats with hereditary central diabetes insipidus. It was found that the biological half-life of the tritiated lysin-vasopressin in the Brattleboro rats did not differ significantly from that found in the R-Amsterdam rats. The highest radioactivities were observed in the neuro- and adenohypophyses and in the kidneys of both the R-Amsterdam and the Brattleboro rats. The accumulation of tritiated LVP was higher in the small intestine of the Brattleboro rats than in that of the R-Amsterdam animals. The results have led to the conclusion that the accelerated elimination of vasopressin and its pathologic organ-accumulation are probably not involved in the water metabolism disturbance of Brattleboro rats with hereditary hypothalamic diabetes insipidus. (author)

  12. Improved half-life determination and β-delayed γ-ray spectroscopy for 18Ne decay

    Science.gov (United States)

    Grinyer, G. F.; Ball, G. C.; Bouzomita, H.; Ettenauer, S.; Finlay, P.; Garnsworthy, A. B.; Garrett, P. E.; Green, K. L.; Hackman, G.; Leslie, J. R.; Pearson, C. J.; Rand, E. T.; Sumithrarachchi, C. S.; Svensson, C. E.; Thomas, J. C.; Triambak, S.; Williams, S. J.

    2013-04-01

    The half-life of the superallowed Fermi β+ emitter 18Ne has been determined to ±0.07% precision by counting 1042 keV delayed γ rays that follow approximately 8% of all β decays. The deduced half-life, T1/2=1.6648(11) s, includes a 0.7% correction that accounts for systematic losses associated with rate-dependent detector pulse pileup that was determined using a recently developed γ-ray photopeak-counting technique. This result is a factor of two times more precise than, and in excellent agreement with, a previous lower-statistics measurement that employed the same experimental setup. High-resolution β-delayed γ-ray spectroscopy results for the relative γ-ray intensities and β-decay branching ratios to excited states in the daughter 18F are also presented.

  13. Measurement of the two neutrino double beta decay half-life of Zr-96 with the NEMO-3 detector

    Energy Technology Data Exchange (ETDEWEB)

    Argyriades, J. [LAL, Universite Paris-Sud 11, CNRS/IN2P3, F-91405 Orsay (France); Arnold, R. [IPHC, Universite de Strasbourg, CNRS/IN2P3, F-67037 Strasbourg (France); Augier, C. [LAL, Universite Paris-Sud 11, CNRS/IN2P3, F-91405 Orsay (France); Baker, J. [INL, Idaho National Laboratory, 83415 Idaho Falls (United States); Barabash, A.S. [ITEP, Institute of Theoretical and Experimental Physics, 117259 Moscow (Russian Federation); Basharina-Freshville, A. [University College London, WC1E 6BT London (United Kingdom); Bongrand, M. [LAL, Universite Paris-Sud 11, CNRS/IN2P3, F-91405 Orsay (France); Broudin-Bay, G. [Universite Bordeaux, CENBG, UMR 5797, F-33175 Gradignan (France); CNRS/IN2P3, Centre d' Etudes Nucleaires de Bordeaux Gradignan, UMR5797, F-33175 Gradignan (France); Brudanin, V. [JINR, Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Caffrey, A.J. [INL, Idaho National Laboratory, 83415 Idaho Falls (United States); Chapon, A. [LPC, ENSICAEN, Universite de Caen, CNRS/IN2P3, F-14032 Caen (France); Chauveau, E. [Universite Bordeaux, CENBG, UMR 5797, F-33175 Gradignan (France); CNRS/IN2P3, Centre d' Etudes Nucleaires de Bordeaux Gradignan, UMR5797, F-33175 Gradignan (France); Daraktchieva, Z. [University College London, WC1E 6BT London (United Kingdom); Durand, D. [LPC, ENSICAEN, Universite de Caen, CNRS/IN2P3, F-14032 Caen (France); Egorov, V. [JINR, Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Fatemi-Ghomi, N. [University of Manchester, M13 9PL Manchester (United Kingdom); Flack, R. [University College London, WC1E 6BT London (United Kingdom); Guillon, B. [LPC, ENSICAEN, Universite de Caen, CNRS/IN2P3, F-14032 Caen (France); Hubert, Ph. [Universite Bordeaux, CENBG, UMR 5797, F-33175 Gradignan (France); CNRS/IN2P3, Centre d' Etudes Nucleaires de Bordeaux Gradignan, UMR5797, F-33175 Gradignan (France); Jullian, S. [LAL, Universite Paris-Sud 11, CNRS/IN2P3, F-91405 Orsay (France)

    2010-12-08

    Using 9.4 g of {sup 96}Zr isotope and 1221 days of data from the NEMO-3 detector corresponding to 0.031 kg y, the obtained 2{nu}{beta}{beta} decay half-life measurement is T{sub 1/2}{sup 2{nu}=}[2.35{+-}0.14(stat){+-}0.16(syst)]x10{sup 19} yr. Different characteristics of the final state electrons have been studied, such as the energy sum, individual electron energy, and angular distribution. The 2{nu} nuclear matrix element is extracted using the measured 2{nu}{beta}{beta} half-life and is M{sup 2{nu}=}0.049{+-}0.002. Constraints on 0{nu}{beta}{beta} decay have also been set.

  14. Near-optimum procedure for half-life measurement by high-resolution gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Parker, J.L.

    1989-01-01

    A near-optimum procedure for using high-resolution γ-ray spectrometry to measure the half-lives of appropriate γ-ray- emitting-nuclides is presented. Among the important points of the procedure are the employment of the reference source method for implicit correction of pileup and deadtime losses; the use of full-energy peak-area ratios as the fundamental measured quantities; and continuous, high-rate data acquisition to obtain good results in a fraction of a half-life if desired. Equations are given for estimating the precision of the computed half-lives in terms of total measurement time, number of spectral acquisitions, and the precision of peak-area ratios. Results of 169 Yb half-life measurements are given as an example of the procedure's application. 3 refs., 2 tabs

  15. Electron cyclotron resonance heating in a short cylindrical plasma ...

    Indian Academy of Sciences (India)

    The power mode conversion efficiency is estimated to be ... has also found application in electron cyclotron current drive (ECCD) in fusion ... (few GHz) of microwave sources, a small linear ECR plasma system can also serve ..... References.

  16. Usefulness of analytical CEA doubling time and half-life time for overlooked synchronous metastases in colorectal carcinoma.

    Science.gov (United States)

    Ito, Katsuki; Hibi, Kenji; Ando, Hideyuki; Hidemura, Kazuhiko; Yamazaki, Taiji; Akiyama, Seiji; Nakao, Akimasa

    2002-02-01

    Measurement of carcinoembryonic antigen (CEA) has been widely applied to detect recurrence, especially of colorectal carcinoma. The validity however, is still controversial. We investigated serial changes in CEA values to calculate whether the CEA doubling time and half-life time could predict metastatic progression or prognosis in colorectal carcinoma. Pre- and post-operative serial serum CEA contents were determined in 22 cases of colorectal cancer with or without metastasis. CEA values were determined by enzyme immunoassay (EIA). Patients were assigned depending upon survival time (within vs. more than 18 months after primary resection) for assessment of CEA doubling time. From the gradient of the semi-logarithmic CEA graph, the preoperative doubling time was calculated and the postoperative half-life time was estimated according to the diagnosis of metastases within 2 years after primary resection [metastasis (+) or (-)]. In spite of the effect of curative re-operation of metastatic lesions or of postoperative adjuvant chemotherapy, the CEA doubling time of the groups showed a relation with prognosis (p = 0.045, Student's t-test) when the patients were divided into >18 and time. The CEA half-life time of the groups without overlooked metastases was statistically longer than those with (mean +/- SD 8.01 +/- 2.07 and 4.33 +/- 1.11, respectively, p Clearance (k) showed a significant difference between the groups (p time appeared to be a less independent prognostic factor, whereas prolongation of the CEA half-life time might potentially suggest the existence of overlooked synchronous metastases from colorectal carcinoma.

  17. On the statistical evaluation of inconsistent measurement results illustrated on the example of the 90Sr half-life

    International Nuclear Information System (INIS)

    Zijp, W.L.

    1985-12-01

    The problem how to make an objective evaluation of inconsistent numerical observations made by different authors or laboratories on the same physical quantity is dealt with. The problem is treated in a practical way in the light of the example on the half-life of 90 Sr, and it is to some extent a response to a document by Gray (1985) on the same topic

  18. Research on imploded plasma heating by short pulse laser for fast ignition

    International Nuclear Information System (INIS)

    Kodama, R.; Kitagawa, Y.; Mima, K.

    2001-01-01

    Since the peta watt module (PWM) laser was constructed in 1995, investigated are heating processes of imploded plasmas by intense short pulse lasers. In order to heat the dense plasma locally, a heating laser pulse should be guided into compressed plasmas as deeply as possible. Since the last IAEA Fusion Conference, the feasibility of fast ignition has been investigated by using the short pulse GEKKO MII glass laser and the PWM laser with GEKKO XII laser. We found that relativistic electrons are generated efficiently in a preformed plasma to heat dense plasmas. The coupling efficiency of short pulse laser energy to a solid density plasma is 40% when no plasmas are pre-formed, and 20% when a large scale plasma is formed by a long pulse laser pre-irradiation. The experimental results are confirmed by numerical simulations using the simulation code 'MONET' which stands for the Monte-Carlo Electron Transport code developed at Osaka. In the GEKKO XII and PWM laser experiments, intense heating pulses are injected into imploded plasmas. As a result of the injection of heating pulse, it is found that high energy electrons and ions could penetrate into imploded core plasmas to enhance neutron yield by factor 3∼5. (author)

  19. The Use of Gene Ontology Term and KEGG Pathway Enrichment for Analysis of Drug Half-Life.

    Directory of Open Access Journals (Sweden)

    Yu-Hang Zhang

    Full Text Available A drug's biological half-life is defined as the time required for the human body to metabolize or eliminate 50% of the initial drug dosage. Correctly measuring the half-life of a given drug is helpful for the safe and accurate usage of the drug. In this study, we investigated which gene ontology (GO terms and biological pathways were highly related to the determination of drug half-life. The investigated drugs, with known half-lives, were analyzed based on their enrichment scores for associated GO terms and KEGG pathways. These scores indicate which GO terms or KEGG pathways the drug targets. The feature selection method, minimum redundancy maximum relevance, was used to analyze these GO terms and KEGG pathways and to identify important GO terms and pathways, such as sodium-independent organic anion transmembrane transporter activity (GO:0015347, monoamine transmembrane transporter activity (GO:0008504, negative regulation of synaptic transmission (GO:0050805, neuroactive ligand-receptor interaction (hsa04080, serotonergic synapse (hsa04726, and linoleic acid metabolism (hsa00591, among others. This analysis confirmed our results and may show evidence for a new method in studying drug half-lives and building effective computational methods for the prediction of drug half-lives.

  20. Influence of antithyroid medication on effective half-life and uptake of 131 I following radioiodine therapy

    International Nuclear Information System (INIS)

    Moka, D.; Voth, E.; Schicha, H.

    1997-01-01

    Aim: A radioiodine therapy (RIT) in thyrotoxic patients receiving antithyroid drugs (ATD) leads in comparison to nonpretreated patients either to higher therapeutic doses or to higher treatment failure rates. Aim of this study was to optimize the effect of RIT in patients pretreated with ATD. Methods: Therefore, the influence of ATD was assessed in 109 patients with shortened effective half-life of 131 I. RIT was performed under stationary conditions. Radioiodine activity of the thyroid gland was stopped three days after RIT. The patients antithyroid medication was stopped three days after RIT. The progress of the first RIT and of a second radioiodine application, which still was necessary in 29 patients, was compared to 32 patients receiving ATD, continuously. Results: Values of effective half-life for 131 I rose significantly from 3.2±0.2 to 5.7±0.2 days (Graves' disease: 3.4 to 5.7 days; toxic goiters' disease: Multifocal autonomy 3.2 to 6.2 days; unifocal autonomy 2.5 auf 5.0 days) 2-3 days after stopping ATD. There was an increase of the 131 I-uptake of a second RIT decreased significantly in patients receiving ATD, continuously. Conclusion: Effective half-life and uptake of 131 I was affected significantly by ATD. The stop taking of ATD after RIT is useful to improve an apparent insufficient RIT in thyrotoxic patients receiving ATD. (orig.) [de

  1. Thirty years after Chernobyl: Long-term determination of 137Cs effective half-life in the lichen Stereocaulon vesuvianum.

    Science.gov (United States)

    Savino, F; Pugliese, M; Quarto, M; Adamo, P; Loffredo, F; De Cicco, F; Roca, V

    2017-06-01

    It has been widely shown that nuclear fallout includes substances, which accumulate in organisms such as crustaceans, fish, mushrooms and lichens, helping to evaluate the activity concentration of contaminants accumulated on a long time. In this context, radiocaesium deposited in soil following the Chernobyl accident on 26 April 1986 is known to have remained persistently available for plant uptake in many areas of Europe. Studies on the lichen Stereocaulon vesuvianum show the plant's high capacity to retain radionuclides from the substrate and the air. After the Chernobyl accident, starting from September 1986, at the Radioactivity Laboratory (LaRa) of the University of Naples Federico II, four monitoring campaigns to evaluate the activity concentration of four isotopes of the two elements caesium and ruthenium ( 134 Cs, 137 Cs, 103 Ru and 106 Ru) were carried out until 1999. This study allowed the effective half-life of 134 Cs and 137 Cs to be estimated. Twenty-eight years after the accident, in December 2014, a further sampling was carried out; only 137 Cs was revealed beyond the detection limits, measuring activity concentrations ranging from 20 to 40 Bq/kg, while the other radionuclides were no longer observed due to their shorter half-life. The last sampling allowed more precise determination of the effective half-life of 137 Cs (6.2 ± 0.1 year), due to the larger dataset on a large time period. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Pondermotive absorption of a short intense laser pulse in a non-uniform plasma

    Energy Technology Data Exchange (ETDEWEB)

    Andreev, A A; Platonov, K Yu [Inst. for Laser Physics, SC ` Vavilov State Optical Inst.` 12, Birzhevaya line, St Petersburg (Russian Federation); Tanaka, K A

    1998-03-01

    An analytical description of the pondermotive absorption mechanism at a short high intense laser pulse interaction with a strong inhomogeneous plasma is presented. The optimal conditions for the maximum of resonance absorption of laser pulse interaction with non-uniform plasma at normal incidence are founded. (author)

  3. On-line nuclear half life and spectroscopic measurements on mass-separated fission product nuclei

    International Nuclear Information System (INIS)

    McDonald, J.; Fogelberg, B.; Baecklin, A.

    1979-01-01

    A description is given of the methods and equipment employed for nuclear spectroscopy studies of short lived fission product nuclei at the OSIRIS ISOL facility in Studsvik, Sweden. Furthermore a table of new nuclear half-lives measured with this equipment is presented. (author)

  4. The Present Status of the Half-Life Measuring Equipment and Technique at Studsvik

    Energy Technology Data Exchange (ETDEWEB)

    Malmskog, S G

    1967-10-15

    The present article presents the equipment and technique used at Studsvik for measuring half-lives of nuclear excited states using the delayed coincidence method. The experimental set up includes an electron-electron coincidence spectrometer and a fast pneumatic rabbit system attached to the high flux reactor R2 at Studsvik. Special efforts have been made to adapt the system for work with short lived radioactive isotopes with decay times of the order of seconds.

  5. Conditions of the existence of 'short circuit' effect for plasma in a conducting cylinder

    International Nuclear Information System (INIS)

    Zhilinskij, A.P.; Kuteev, B.V.

    1975-01-01

    It has been experimentally established that in a cylindrical container with conducting side and end walls, the phenomenon of short circuit (the Symon effect) is not always realized. The short circuiting of plane end and of side surfaces causes an acceleration of a plasma decay only during the initial stage in a comparatively short time. Characteristic lifetimes during the late stage remain unchanged in this case. In conditions of a stable plasma they correspond to classical values of the plasma decay constant at the ambipolar diffusion of charged particles along and across force lines of a magnetic field. A fundamental change in the nature of the diffusion and a decrease of the plasma lifetime almost by two orders are realized in an instrument in which an end conducting wall for plasma in created with a short cylinder at the end of a solenoid in a sharply nonuniform magnetic field. The data obtained testify to the fact that the short circuit effect takes place in conditions when on boundaries of plasma the possibility of simultaneous flowing of unipolar electron flows along and of ion flows across a magnetic field is assured. The results of the experiments are compared with a theory

  6. Full-wave solution of short impulses in inhomogeneous plasma

    International Nuclear Information System (INIS)

    Ferencz, Orsolya E.

    2005-01-01

    In this paper the problem of real impulse propagation in arbitrarily inhomogeneous media will be presented on a fundamentally new, general, theoretical way. The general problem of wave propagation of monochromatic signals in inhomogeneous media was enlightened. The earlier theoretical models for spatial inhomogeneities have some errors regarding the structure of the resultant signal originated from backward and forward propagating parts. The application of the method of inhomogeneous basic modes (MIBM) and the complete full-wave solution of arbitrarily shaped non-monochromatic plane waves in plasmas made it possible to obtain a better description of the problem, on a fully analytical way, directly from Maxwell's equations. The model investigated in this paper is inhomogeneous of arbitrary order (while the wave pattern can exist), anisotropic (magnetized), linear, cold plasma, in which the gradient of the one-dimensional spatial inhomogeneity is parallel to the direction of propagation. (author)

  7. Phenobarbital administration every eight hours: improvement of seizure management in idiopathic epileptic dogs with decreased phenobarbital elimination half-life.

    Science.gov (United States)

    Stabile, F; Barnett, C R; De Risio, L

    2017-02-18

    Estimated prevalence of canine idiopathic epilepsy is 0.6 per cent in the first-opinion canine population in the UK. Phenobarbital monotherapy has been reported to reduce/eradicate seizure activity in 60-93 per cent of idiopathic epileptic dogs (IEDs). The objective of this study was to evaluate safety and efficacy of the administration of phenobarbital orally every eight hours in IEDs with phenobarbital elimination half-life less than 20 hours. Medical records of 10 IEDs in which steady state trough serum phenobarbital levels were within the reference range and phenobarbital elimination half-life had become less than 20 hours following prolonged administration every 12 hours were reviewed. Side effects and seizure frequency when phenobarbital was administered every 12 hours or 8 hours were compared. In all dogs the side effects of the antiepileptic medication treatment improved. When phenobarbital was administered every eight hours, 9/10 dogs experienced improvement in seizure frequency and 8/10 dogs maintained seizure freedom for a period three times longer than the longest interictal interval period previously recorded. Reduction in the severity and number of clusters of seizures was recorded in one of the remaining two dogs. The administration of phenobarbital orally every eight hours in IEDs with decreased phenobarbital elimination half-life appears safe and can improve seizure management. The results of this study were presented in abstract form (poster) for the 28th symposium of the European Society of Veterinary Neurology - European College of Veterinary Neurology (ESVN), September 18-19, 2015, Amsterdam, Netherlands. British Veterinary Association.

  8. Advances in therapeutic Fc engineering - modulation of IgG associated effector functions and serum half-life

    Directory of Open Access Journals (Sweden)

    Abhishek Saxena

    2016-12-01

    Full Text Available Today monoclonal immunoglobulin gamma (IgG antibodies have become a major option in cancer therapy especially for the patients with advanced or metastatic cancers. Efficacy of monoclonal antibodies (mAbs are achieved through both its antigen binding fragment (Fab and crystallizable fragment (Fc. Fab can specifically recognize tumor associated antigen (TAA and thus modulate TAA-linked downstream signaling pathways that may lead to inhibition of tumor growth, induction of tumor apoptosis and differentiation. The Fc region can further improve mAbs’ efficacy by mediating effector functions such as antibody-dependent cellular cytotoxicity (ADCC, complement-dependent cytotoxicity (CDC and antibody dependent cell-mediated phagocytosis (ADCP. Moreover, Fc is the region interacting with the neonatal Fc receptor (FcRn in a pH-dependent manner that can slow down IgG’s degradation and extend its serum half-life. Loss of the antibody Fc region dramatically shortens its serum half-life and weakens its anti-cancer effects. Given the essential roles that the Fc region plays in the modulation of the efficacy of mAb in cancer treatment, Fc engineering has been extensively studied in the past years. This review focuses on the recent advances in therapeutic Fc engineering that modulates its related effector functions and serum half-life. We also discuss the progress made in aglycosylated mAb development that may substantially reduce cost of manufacture but maintain similar efficacies as conventional glycosylated mAb. Finally, we highlight several Fc engineering based mAbs under clinical trials.

  9. Diurnal lamotrigine plasma level fluctuations: clinical significance and indication of shorter half-life with chronic administration

    DEFF Research Database (Denmark)

    Nielsen, K.A.; Dahl, M.; Tommerup, E.

    2008-01-01

    -daily regimens without pharmacokinetic interactions exhibited C(min)/C(max) ratios between 0.62 and 0.69. Fluctuations were smaller in those co-medicated with valproate, and reached a ratio of 0.55 in those co-medicated with phenobarbital. The C(max) was as much as 58% above the MTL. Therefore, verification...

  10. High-precision measurement of the 19Ne half-life and implications for right-handed weak currents.

    Science.gov (United States)

    Triambak, S; Finlay, P; Sumithrarachchi, C S; Hackman, G; Ball, G C; Garrett, P E; Svensson, C E; Cross, D S; Garnsworthy, A B; Kshetri, R; Orce, J N; Pearson, M R; Tardiff, E R; Al-Falou, H; Austin, R A E; Churchman, R; Djongolov, M K; D'Entremont, R; Kierans, C; Milovanovic, L; O'Hagan, S; Reeve, S; Sjue, S K L; Williams, S J

    2012-07-27

    We report a precise determination of the (19)Ne half-life to be T(1/2)=17.262±0.007 s. This result disagrees with the most recent precision measurements and is important for placing bounds on predicted right-handed interactions that are absent in the current standard model. We are able to identify and disentangle two competing systematic effects that influence the accuracy of such measurements. Our findings prompt a reassessment of results from previous high-precision lifetime measurements that used similar equipment and methods.

  11. A Half-Life Measurement of the 343.4 keV Level in {sup 175}Lu

    Energy Technology Data Exchange (ETDEWEB)

    Hoejeberg, M; Malmskog, S G

    1969-05-15

    Great theoretical interest has recently been shown in the asymptotically forbidden 5/2 5/2+ [402] - 7/2 7/2+ [404] M1-transitions in {sup 181}Ta and {sup 175}Lu . Half-lives of the 5/2 5/2+ [402] level in {sup 175}Lu have been reported which differ by more than a factor of 10. Using an electron-electron coincidence spectrometer the half-life of this level has been re-measured and a value of (0.26 {+-} 0.02) nsec has been established.

  12. Biological half-life and distribution of radiocesium in a contaminated population of green treefrogs Hyla cinerea

    International Nuclear Information System (INIS)

    Dapson, R.W.; Kaplan, L.

    1975-01-01

    Radiocesium content of adult male green treefrogs Hyla cinerea from a contaminated habitat is adequately described by a log normal distribution with mean 2.277 log 10 pCi g -1 dry wt (189.2 pCi g -1 ) and variance of 0.031. There was significant negative correlation of body burden with body length and weight (p 2 = 0.10). Biological half-life of radiocesium in unfed, captive frogs held at 20 deg - 30 deg C averaged 30.1 d. (author)

  13. High-Precision Measurement of the Ne19 Half-Life and Implications for Right-Handed Weak Currents

    Science.gov (United States)

    Triambak, S.; Finlay, P.; Sumithrarachchi, C. S.; Hackman, G.; Ball, G. C.; Garrett, P. E.; Svensson, C. E.; Cross, D. S.; Garnsworthy, A. B.; Kshetri, R.; Orce, J. N.; Pearson, M. R.; Tardiff, E. R.; Al-Falou, H.; Austin, R. A. E.; Churchman, R.; Djongolov, M. K.; D'Entremont, R.; Kierans, C.; Milovanovic, L.; O'Hagan, S.; Reeve, S.; Sjue, S. K. L.; Williams, S. J.

    2012-07-01

    We report a precise determination of the Ne19 half-life to be T1/2=17.262±0.007s. This result disagrees with the most recent precision measurements and is important for placing bounds on predicted right-handed interactions that are absent in the current standard model. We are able to identify and disentangle two competing systematic effects that influence the accuracy of such measurements. Our findings prompt a reassessment of results from previous high-precision lifetime measurements that used similar equipment and methods.

  14. The effective and environmental half-life of 137Cs at Coral Islands at the former US nuclear test site

    International Nuclear Information System (INIS)

    Robison, William L.; Conrado, Cynthia L.; Bogen, Kenneth T.; Stoker, A. Carol

    2003-01-01

    The United States (US) conducted nuclear weapons testing from 1946 to 1958 at Bikini and Enewetak Atolls in the northern Marshall Islands. Based on previous detailed dose assessments for Bikini, Enewetak, Rongelap, and Utirik Atolls over a period of 28 years, cesium-137 ( 137 Cs) at Bikini Atoll contributes about 85-89% of the total estimated dose through the terrestrial food chain as a result of uptake of 137 Cs by food crops. The estimated integral 30, 50, and 70-year doses were based on the radiological decay of 137 Cs (30-year half-life) and other radionuclides. However, there is a continuing inventory of 137 Cs and 90 Sr in the fresh water portion of the groundwater at all contaminated atolls even though the turnover rate of the fresh groundwater is about 5 years. This is evidence that a portion of the soluble fraction of 137 Cs and 90 Sr inventory in the soil is lost by transport to groundwater when rainfall is heavy enough to cause recharge of the lens, resulting in loss of 137 Cs from the soil column and root zone of the plants. This loss is in addition to that caused by radioactive decay. The effective rate of loss was determined by two methods: (1) indirectly, from time-dependent studies of the 137 Cs concentration in leaves of Pisonia grandis, Guettarda specosia, Tournefortia argentea (also called Messerschmidia), Scaevola taccada, and fruit from Pandanus and coconut trees (Cocos nucifera L.), and (2) more directly, by evaluating the 137 Cs/ 90 Sr ratios at Bikini Atoll. The mean (and its lower and upper 95% confidence limits) for effective half-life and for environmental-loss half-life (ELH) based on all the trees studied on Rongelap, Bikini, and Enewetak Atolls are 8.5 years (8.0 years, 9.8 years), and 12 years (11 years, 15 years), respectively. The ELH based on the 137 Cs/ 90 Sr ratios in soil in 1987 relative to the 137 Cs/ 90 Sr ratios at the time of deposition in 1954 is less than 17 years. The magnitude of the decrease below 17 years depends on

  15. The effective and environmental half-life of 137Cs at Coral Islands at the former US nuclear test site.

    Science.gov (United States)

    Robison, William L; Conrado, Cynthia L; Bogen, Kenneth T; Stoker, A Carol

    2003-01-01

    The United States (US) conducted nuclear weapons testing from 1946 to 1958 at Bikini and Enewetak Atolls in the northern Marshall Islands. Based on previous detailed dose assessments for Bikini, Enewetak, Rongelap, and Utirik Atolls over a period of 28 years, cesium-137 (137Cs) at Bikini Atoll contributes about 85-89% of the total estimated dose through the terrestrial food chain as a result of uptake of 137Cs by food crops. The estimated integral 30, 50, and 70-year doses were based on the radiological decay of 137Cs (30-year half-life) and other radionuclides. However, there is a continuing inventory of 137Cs and 90Sr in the fresh water portion of the groundwater at all contaminated atolls even though the turnover rate of the fresh groundwater is about 5 years. This is evidence that a portion of the soluble fraction of 137Cs and 90Sr inventory in the soil is lost by transport to groundwater when rainfall is heavy enough to cause recharge of the lens, resulting in loss of 137Cs from the soil column and root zone of the plants. This loss is in addition to that caused by radioactive decay. The effective rate of loss was determined by two methods: (1) indirectly, from time-dependent studies of the 137Cs concentration in leaves of Pisonia grandis, Guettarda specosia, Tournefortia argentea (also called Messerschmidia), Scaevola taccada, and fruit from Pandanus and coconut trees (Cocos nucifera L.), and (2) more directly, by evaluating the 137Cs/90Sr ratios at Bikini Atoll. The mean (and its lower and upper 95% confidence limits) for effective half-life and for environmental-loss half-life (ELH) based on all the trees studied on Rongelap, Bikini, and Enewetak Atolls are 8.5 years (8.0 years, 9.8 years), and 12 years (11 years, 15 years), respectively. The ELH based on the 137Cs/90Sr ratios in soil in 1987 relative to the 137Cs/90Sr ratios at the time of deposition in 1954 is less than 17 years. The magnitude of the decrease below 17 years depends on the ELH for 90Sr

  16. The Half-Life of the HSV-1 1.5 kb LAT Intron is similar to the half-Life of the 2.0 kb LAT Intron

    Science.gov (United States)

    Brinkman, Kerry K.; Mishra, Prakhar; Fraser, Nigel W.

    2013-01-01

    Herpes Simplex Virus type 1 (HSV-1) establishes a latent infection in the sensory neurons of the peripheral nervous system of humans. Although about 80 genes are expressed during the lytic cycle of the virus infection, essentially only one gene is expressed during the latent cycle. This gene is known as the latency associated transcript (LAT) and it appears to play a role in the latency cycle through an anti-apoptotic function in the 5’ end of the gene and miRNA encoded along the length of the transcript which down regulate some of the viral immediate early (IE) gene products. The LAT gene is about 8.3 kb long and consists of two exons separated by an unusual intron. The intron between the exons consists of two nested introns. This arrangement of introns has been called a twintron. Furthermore, the larger (2 kb) intron has been shown to be very stable. In this study we measure the stability of the shorter 1.5 kb nested intron and find its half-life is similar to the longer intron. This was achieved by deleting the 0.5 kb overlapping intron from a plasmid construct designed to express the LAT transcript from a tet-inducible promoter, and measuring the half-life of the 1.5 kb intron in tissue culture cells. This finding supports the hypothesis that it is the common branch-point region of these nested introns that is responsible for their stability. PMID:23335177

  17. Long and short term effects of plasma treatment on meristematic plant cells

    Science.gov (United States)

    Puač, N.; Živković, S.; Selaković, N.; Milutinović, M.; Boljević, J.; Malović, G.; Petrović, Z. Lj.

    2014-05-01

    In this paper, we will present results of plasma treatments of meristematic cells of Daucus carota. Plasma needle was used as an atmospheric pressure/gas composition source of non-equilibrium plasma in all treatments. Activity of antioxidant enzymes superoxide dismutase and catalase was measured immediately after plasma treatment and after two weeks following the treatment. Superoxide dismutase activity was increased in samples immediately after the plasma treatment. On the other hand, catalase activity was much higher in treated samples when measured two weeks after plasma treatment. These results show that there is a direct proof of the triggering of signal transduction in the cells by two reactive oxygen species H2O2 and O2-, causing enzyme activity and short and long term effects even during the growth of calli, where the information is passed to newborn cells over the period of two weeks.

  18. Fab-dsFv: A bispecific antibody format with extended serum half-life through albumin binding.

    Science.gov (United States)

    Davé, Emma; Adams, Ralph; Zaccheo, Oliver; Carrington, Bruce; Compson, Joanne E; Dugdale, Sarah; Airey, Michael; Malcolm, Sarah; Hailu, Hanna; Wild, Gavin; Turner, Alison; Heads, James; Sarkar, Kaushik; Ventom, Andrew; Marshall, Diane; Jairaj, Mark; Kopotsha, Tim; Christodoulou, Louis; Zamacona, Miren; Lawson, Alastair D; Heywood, Sam; Humphreys, David P

    2016-10-01

    An antibody format, termed Fab-dsFv, has been designed for clinical indications that require monovalent target binding in the absence of direct Fc receptor (FcR) binding while retaining substantial serum presence. The variable fragment (Fv) domain of a humanized albumin-binding antibody was fused to the C-termini of Fab constant domains, such that the VL and VH domains were individually connected to the Cκ and CH1 domains by peptide linkers, respectively. The anti-albumin Fv was selected for properties thought to be desirable to ensure a durable serum half-life mediated via FcRn. The Fv domain was further stabilized by an inter-domain disulfide bond. The bispecific format was shown to be thermodynamically and biophysically stable, and retained good affinity and efficacy to both antigens simultaneously. In in vivo studies, the serum half-life of Fab-dsFv, 2.6 d in mice and 7.9 d in cynomolgus monkeys, was equivalent to Fab'-PEG.

  19. Ultra-High Precision Half-Life Measurement for the Superallowed &+circ; Emitter ^26Al^m

    Science.gov (United States)

    Finlay, P.; Demand, G.; Garrett, P. E.; Leach, K. G.; Phillips, A. A.; Sumithrarachchi, C. S.; Svensson, C. E.; Triambak, S.; Grinyer, G. F.; Leslie, J. R.; Andreoiu, C.; Cross, D.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Djongolov, M.; Ettenauer, S.; Hackman, G.; Pearson, C. J.; Williams, S. J.

    2009-10-01

    The calculated nuclear structure dependent correction for ^26Al^m (δC-δNS= 0.305(27)% [1]) is smaller by nearly a factor of two than the other twelve precision superallowed cases, making it an ideal case to pursue a reduction in the experimental errors contributing to the Ft value. An ultra-high precision half-life measurement for the superallowed &+circ; emitter ^26Al^m has been made at the Isotope Separator and Accelerator (ISAC) facility at TRIUMF in Vancouver, Canada. A beam of ˜10^5 ^26Al^m/s was delivered in October 2007 and its decay was observed using a 4π continuous gas flow proportional counter as part of an ongoing experimental program in superallowed Fermi β decay studies. With a statistical precision of ˜0.008%, the present work represents the single most precise measurement of any superallowed half-life to date. [4pt] [1] I.S. Towner and J.C. Hardy, Phys. Rev. C 79, 055502 (2009).

  20. High-Precision Half-Life and Branching Ratio Measurements for the Superallowed β+ Emitter 26Alm

    Science.gov (United States)

    Finlay, P.; Svensson, C. E.; Demand, G. A.; Garrett, P. E.; Green, K. L.; Leach, K. G.; Phillips, A. A.; Rand, E. T.; Ball, G.; Bandyopadhyay, D.; Djongolov, M.; Ettenauer, S.; Hackman, G.; Pearson, C. J.; Leslie, J. R.; Andreoiu, C.; Cross, D.; Austin, R. A. E.; Grinyer, G. F.; Sumithrarachchi, C. S.; Williams, S. J.; Triambak, S.

    2013-03-01

    High-precision half-life and branching-ratio measurements for the superallowed β+ emitter 26Alm were performed at the TRIUMF-ISAC radioactive ion beam facility. An upper limit of ≤ 15 ppm at 90% C.L. was determined for the sum of all possible non-analogue β+/EC decay branches of 26Alm, yielding a superallowed branching ratio of 100.0000+0-0.0015%. A value of T1/2 = 6:34654(76) s was determined for the 26Alm half-life which is consistent with, but 2.5 times more precise than, the previous world average. Combining these results with world-average measurements yields an ft value of 3037.58(60) s, the most precisely determined for any superallowed emitting nucleus to date. This high-precision ft value for 26Alm provides a new benchmark to refine theoretical models of isospin-symmetry-breaking effects in superallowed β decays.

  1. RBC-/Cr-51/ half-life and albumin turnover in growing Beagle dogs during chronic radial acceleration

    Science.gov (United States)

    Beckman, D. A.; Evans, J. W.; Oyama, J.

    1979-01-01

    The effects of chronic centrifugation on growing Beagle dogs exposed to -2 or -2.6 Gx on albumin and RBC turnover rates, albumin concentration and space, and total blood volume were determined and compared with caged and run control of animals. Albumin-(I-125) and autologous RBC-(Cr-51) preparations were injected into all dogs at day 82 of the centrifugation periods, and the disappearance curves were determined by successive bleedings of the animals over the next 35 d, during which the centrifugation was continued. There were no differences in albumin turnover rates or space. Two populations of RBCs were found in both centrifugated groups, one with a normal half-life of 27 + or - 1 S.E.M. d, and one with a significantly (p less than 0.01) shorter half-life of 15 + or - 2 S.E.M. d. An absolute polycythemia was also observed in both centrifuged groups. The results suggest that chronic centrifugation acts through some as-yet unknown mechanism to affect RBC population kinetics.

  2. Short-range wakefields generated in the blowout regime of plasma-wakefield acceleration

    Science.gov (United States)

    Stupakov, G.

    2018-04-01

    In the past, calculation of wakefields generated by an electron bunch propagating in a plasma has been carried out in linear approximation, where the plasma perturbation can be assumed small and plasma equations of motion linearized. This approximation breaks down in the blowout regime where a high-density electron driver expels plasma electrons from its path and creates a cavity void of electrons in its wake. In this paper, we develop a technique that allows us to calculate short-range longitudinal and transverse wakes generated by a witness bunch being accelerated inside the cavity. Our results can be used for studies of the beam loading and the hosing instability of the witness bunch in plasma-wakefield and laser-wakefield acceleration.

  3. Self-focusing and guiding of short laser pulses in ionizing gases and plasmas

    International Nuclear Information System (INIS)

    Esarey, E.; Sprangle, P.; Krall, J.; Ting, A.

    1997-01-01

    The propagation of intense laser pulses in gases and plasmas is relevant to a wide range of applications, including laser-driven accelerators, laser-plasma channeling, harmonic generation, supercontinuum generation, X-ray lasers, and laser-fusion schemes. Here, several features of intense, short-pulse (≤1 ps) laser propagation in gases undergoing ionization and in plasmas are reviewed, discussed, and analyzed. The wave equations for laser pulse propagation in a gas undergoing ionization and in a plasma are derived. The source-dependent expansion method is discussed, which is a general method for solving the paraxial wave equation with nonlinear source terms. In gases, the propagation of high-power (near the critical power) laser pulses is considered including the effects of diffraction, nonlinear self-focusing, ionization, and plasma generation. Self-guided solutions and the stability of these solutions are discussed. In plasmas, optical guiding by relativistic effects, ponderomotive effects, and preformed density channels is considered. The self-consistent plasma response is discussed, including plasma wave effects and instabilities such as self-modulation. Recent experiments on the guiding of laser pulses in gases and in plasmas are briefly summarized

  4. Relationship between isotope half-life and prostatic edema for optimal prostate dose coverage in permanent seed implants

    International Nuclear Information System (INIS)

    Villeneuve, Maxime; Leclerc, Ghyslain; Lessard, Etienne; Pouliot, Jean; Beaulieu, Luc

    2008-01-01

    The robustness of treatment planning to prostatic edema for three different isotopes ( 125 I, 103 Pd, and 131 Cs) is explored using dynamical dose calculations on 25 different clinical prostate cases. The treatment plans were made using the inverse planning by simulated annealing (IPSA) algorithm. The prescription was 144, 127, and 125 Gy for 125 I, 131 Cs, and 103 Pd, respectively. For each isotope, three dose distribution schemes were used to impose different protection levels to the urethra: V 120 =0%, V 150 =0%, and V 150 =30%. Eleven initial edema values were considered ranging from 1.0 (no edema) to 2.0 (100%). The edema was assumed to resolve exponentially with time. The prostate volume, seed positions, and seed activity were dynamically tracked to produce the final dose distribution. Edema decay half-lives of 10, 30, and 50 days were used. A total of 675 dynamical calculations were performed for each initial edema value. For the 125 I isotope, limiting the urethra V 120 to 0% leads to a prostate D 90 under 140 Gy for initial edema values above 1.5. Planning with urethra V 150 at 0% provides a good response to the edema; the prostate D 90 remains higher than 140 Gy for edema values up to 1.8 and a half-life of 30 days or less. For 103 Pd, the prostate D 90 is under 97% of the prescription dose for approximately 66%, 40%, and 30% of edema values for urethra V 120 =0%, V 150 =0%, and V 150 =30%, respectively. Similar behavior is seen for 131 Cs and the center of the prostate becomes 'cold' for almost all edema scenarios. The magnitude of the edema following prostate brachytherapy, as well as the half-life of the isotope used and that of the edema resorption, all have important impacts on the dose distribution. The 125 I isotope with its longer half-life is more robust to prostatic edema. Setting up good planning objectives can provide an adequate compromise between organ doses and robustness. This is even more important since seed misplacements will contribute

  5. Direct Deposition Effect on the Distribution of Radiocesium in Persimmon Trees and the Effective Half-life

    Energy Technology Data Exchange (ETDEWEB)

    Tagami, Keiko; Uchida, Shigeo [National Institute of Radiological Sciences, Anagawa 4-9-1, Inage-ku, Chiba 263-7444 (Japan)

    2014-07-01

    Radiocesium ({sup 137}Cs) concentrations in persimmon tree tissues collected at Chiba, about 220 km south from Fukushima Daiichi nuclear power plant (FDNPP), were measured to obtain half-life of radiocesium in the trees. Persimmon (Diospyros kaki) is a deciduous tree and bears edible fruits in autumn. There were no leaves when the sampling area was received the radioactive fallout in March 2011 due to the FDNPP accident; the amount of {sup 137}Cs radioactivity in this area was ca. 13 kBq/m{sup 3} Both {sup 137}Cs and {sup 134}Cs were found in the newly emerged shoots of the persimmon trees collected at 26 April 2011 mainly due to foliar uptake. The concentrations were 1.1 kBq/kg-dry for {sup 137}Cs and 1.3 kBq/kg-dry for {sup 134}Cs. After that, continuous sampling of leaves, branches and fruits of the persimmon trees had been carried out for two years. Immediately after the collection, samples were transferred to our laboratory and weighed to obtain fresh weight. Leaf samples were usually separated into two portions; one portion was washed with tap water to remove dust from the surface and the other portion was not treated. For fruit samples, if it is possible, fruit flesh, peal and non-edible part were separated. All the samples were oven-dried at 80 deg. C for three days at least. Each dried sample was chopped into fine pieces, mixed well, and then transferred into plastic vessels separately. Radioactivity concentration was measured by a Ge-detecting system (Seiko EG and G Ortec) using 3000-40000 s counting intervals. By August 14, 2013, about 140 samples were collected from the trees; about 60 samples were leaves (both washed and untreated). Radiocesium concentrations in tree leaves decreased with time, and the effective half-life was about 190 d; the value was similar to those in branches (160 d for new branches, and 250 d for 1-2 y.o. branches) and fruits (250 d for fruit flesh and 230 d for peals). Thus we concluded that the half-life of radiocesium in

  6. Energy dependence of average half-life of delayed neutron precursors in fast neutron induced fission of 235U and 236U

    International Nuclear Information System (INIS)

    Isaev, S.G.; Piksaikin, L.E.; Kazakov, L.E.; Tarasko, M.Z.

    2000-01-01

    The measurements of relative abundances and periods of delayed neutrons from fast neutron induced fission of 235 U and 236 U have been made at the electrostatic accelerator CG-2.5 at IPPE. The preliminary results were obtained and discussed in the frame of the systematics of the average half-life of delayed neutron precursors. It was shown that the average half-life value in both reactions depends on the energy of primary neutrons [ru

  7. Preliminary Results of IS Plasma Focus as a Breeder of Short-Lived Radioisotopes 12C(d,n)13N

    Science.gov (United States)

    Sadat Kiai, S. M.; Elahi, M.; Adlparvar, S.; Shahhoseini, E.; Sheibani, S.; Ranjber akivaj, H.; Alhooie, S.; Safarien, A.; Farhangi, S.; Aghaei, N.; Amini, S.; Khalaj, M. M.; Zirak, A. R.; Dabirzadeh, A. A.; Soleimani, J.; Torkzadeh, F.; Mousazadeh, M. M.; Moradi, K.; Abdollahzadeh, M.; Talaei, A.; Zaeem, A. A.; Moslehi, A.; Kashani, A.; Babazadeh, A. R.; Bagiyan, F.; Ardestani, M.; Roozbahani, A.; Pourbeigi, H.; Tajik Ahmadi, H.; Ahmadifaghih, M. A.; Mahlooji, M. S.; Mortazavi, B. N.; Zahedi, F.

    2011-04-01

    Modified IS (Iranian Sun) plasma focus (10 kJ,15 kV, 94 μF, 0.1 Hz) has been used to produce the short-lived radioisotope 13N (half-life of 9.97 min) through 12C(d,n)13N nuclear reaction. The filling gas was 1.5-3 torr of hydrogen (60%) deuterium (40%) mixture. The target was solid nuclear grade graphite with 5 mm thick, 9 cm width and 13 in length. The activations of the exogenous target on average of 20 shots (only one-third acceptable) through 10-13 kV produced the 511 keV gamma rays. Another peak found at the 570 keV gamma of which both was measured by a NaI portable gamma spectrometer calibrated by a 137Cs 0.25 μCi sealed reference source with its single line at 661.65 keV and 22Na 0.1 μCi at 511 keV. To measure the gamma rays, the graphite target converts to three different phases; solid graphite, powder graphite, and powder graphite in water solution. The later phase approximately has a doubled activity with respect to the solid graphite target up to 0.5 μCi of 511 keV and 1.1 μCi of 570 keV gamma lines were produced. This increment in activity was perhaps due to structural transformation of graphite powder to nano-particles characteristic in liquid water.

  8. Tests of the methods of analysis of picosecond lifetimes and measurement of the half-life of the 569.6 keV level in 207Pb

    International Nuclear Information System (INIS)

    Lima, E. de; Kawakami, H.; Lima, A. de; Hichwa, R.; Ramayya, A.V.; Hamilton, J.H.; Dunn, W.; Kim, H.J.

    1978-01-01

    Customarily one extracts the half-life of the nuclear state from a delayed time spectrum by an analysis of the centroid shift, the slope and lately by the convolution method. Recently there have been two formulas relating the centroid shift to the half-life of the nuclear state. These two procedures can give different results for the half-life when Tsub(1/2) the same order or less than the time width of one channel. An extensive investigation of these two formulas and precedures has been made by measuring the half-life of the first excited state in 207 Pb at 569.6 keV. This analysis confirms Bay's formula relating the centroid shift to the half-life of the state. The half-life of the 569.6 keV level in 207 Pb is measured to be (129+-3) ps in excellent agreement with Weisskopf's single particle estimate of 128 ps for an E2 transition. (Auth.)

  9. KINETIC MODELLING AND HALF LIFE STUDY OF ADSORPTIVE BIOREMEDIATION OF SOIL ARTIFICIALLY CONTAMINATED WITH BONNY LIGHT CRUDE OIL

    Directory of Open Access Journals (Sweden)

    Samuel Enahoro Agarry

    2015-06-01

    Full Text Available In this study, comparative potential effects of commercial activated carbon (CAC and plantain peel-derived biochar (PPBC of different particle sizes and dosage to stimulate petroleum hydrocarbon biodegradation in soil were investigated. Microcosms containing soil were spiked with weathered Bonny light crude oil (WBLCO (10% w/w and amended with different particle sizes (0.02, 0.07 and 0.48 mm and dosage (20, 30 and 40 g of CAC and PPBC, respectively. The bioremediation experiments were carried out for a period of 28 days under laboratory conditions. The results showed that there was a positive relationship between the rate of petroleum hydrocarbons reduction and presence of the CAC and PPBC in crude oil contaminated soil microcosms. The WBLCO biodegradation data fitted well to the first-order kinetic model. The model revealed that WBLCO contaminated-soil microcosms amended with CAC and PPBC had higher biodegradation rate constants (k as well as lower half-life times (t1/2 than unamended soil (natural attenuation remediation system. The rate constants increased while half-life times decreased with decreased particle size and increased dosage of amendment agents. ANOVA statistical analysis revealed that WBLCO biodegradation in soil was significantly (p = 0.05 influenced by the addition of CAC and biochar amendment agents, respectively. However, Tukey’s post hoc test (at p = 0.05 showed that there was no significant difference in the bioremediation efficiency of CAC and PPBC. Thus, amendment of soils with biochar has the potential to be an inexpensive, efficient, environmentally friendly and relatively novel strategy to mitigate organic compound-contaminated soil.

  10. Plasma HIV-1 tropism and risk of short-term clinical progression to AIDS or death

    DEFF Research Database (Denmark)

    Fontdevila, Maria Casadellà; Cozzi-Lepri, Alessandro; Phillips, Andrew

    2014-01-01

    INTRODUCTION: It is uncertain if plasma HIV-1 tropism is an independent predictor of short-term risk of clinical progression / death, in addition to the CD4 count and HIV RNA level. We conducted a nested case-control study within EuroSIDA to assess this question amongst people with current HIV RNA...

  11. Study of short wavelength turbulence in dense plasmas. Final technical report, September 8, 1981-August 7, 1983

    International Nuclear Information System (INIS)

    Chen, F.F.; Joshi, C.

    1983-10-01

    The work includes studies of four topics: (1) Thomson scattering from short wavelength density fluctuations from laser excited plasmas from solid targets; (2) studies of SBS driven ion acoustic waves and it's harmonics in underdense plasmas; (3) studies of optical mixing excitation of electron plasma waves (high frequency density fluctuations) in theta pinch plasma; and (4) computational studies of high frequency wave excitation by intense laser beams in plasmas

  12. Allowable propagation of short pulse laser beam in a plasma channel and electromagnetic solitary waves

    International Nuclear Information System (INIS)

    Zhang, Shan; Hong, Xue-Ren; Wang, Hong-Yu; Xie, Bai-Song

    2011-01-01

    Nonparaxial and nonlinear propagation of a short intense laser beam in a parabolic plasma channel is analyzed by means of the variational method and nonlinear dynamics. The beam propagation properties are classified by five kinds of behaviors. In particularly, the electromagnetic solitary wave for finite pulse laser is found beside the other four propagation cases including beam periodically oscillating with defocussing and focusing amplitude, constant spot size, beam catastrophic focusing. It is also found that the laser pulse can be allowed to propagate in the plasma channel only when a certain relation for laser parameters and plasma channel parameters is satisfied. For the solitary wave, it may provide an effective way to obtain ultra-short laser pulse.

  13. The physics of megajoule, large-scale, and ultrafast short-scale laser plasmas

    International Nuclear Information System (INIS)

    Campbell, E.M.

    1992-01-01

    Recent advances in laser science and technology have opened new possibilities for the study of high energy density plasma physics. The advances include techniques to control the laser spatial and temporal coherence, and the development of laser architectures and optical materials that have led to the demonstration of compact, short pulse (τ≤10 -12 sec) high brightness lasers, capable of irradiating plasmas with intensities ≥10 18 W/cm 2 . Experiments with reduced laser coherence have shown a substantial decrease in laser-driven parametric instabilities and have extended the parameter range where inverse bremsstrahlung absorption is the dominant coupling process. Beam smoothing with short wavelength lasers should result in inverse bremsstrahlung dominated coupling in the irradiance parameter regimes of the millimeter scale-length plasmas envisioned for the megajoule class lasers for ignition and gain in inertial fusion. In addition new regimes of laser--plasma coupling will become experimentally accessible when plasmas are irradiated with I≥10 18 W/cm 2 . Relativistic effects, extreme profile modification, and electrons heated to energies exceeding 1 MeV are several of the phenomena that are expected. Numerous applications in basic and applied plasma physics will result from these new capabilities

  14. Label-free Fab and Fc affinity/avidity profiling of the antibody complex half-life for polyclonal and monoclonal efficacy screening.

    Science.gov (United States)

    Read, Thomas; Olkhov, Rouslan V; Williamson, E Diane; Shaw, Andrew M

    2015-09-01

    A unified approach to affinity screening for Fab and Fc interactions of an antibody for its antigen and FcγR receptor has been developed. An antigen array is used for the Fab affinity and cross-reactivity screening and protein A/G proxy is the FcγR receptor. The affinities are derived using a simple 1:1 binding model with a consistent error analysis. The association and dissociation kinetics are measured over optimised times for accurate determination. The Fab/Fc affinities are derived for ten antibodies: mAb-actin (mouse), pAb-BSA (sheep), pAb-collagen V (rabbit), pAb-CRP (goat), mAb-F1 (mouse), mAbs (mouse) 7.3, 12.3, 29.3, 36.3 and 46.3 raised against LcrV in Yersinia pestis. The rate of the dissociation of antigen-antibody complexes relates directly to their immunological function as does the Fc-FcγR complex and a new half-life plot has been defined with a Fab/Fc half-life range of 17-470 min. The upper half-life value points to surface avidity. Two antibodies that are protective as an immunotherapy define a Fab half-life >250 min and an Fc half-life >50 min as characteristics of ideal interactions which can form the basis of an antibody screen for immunotherapy.

  15. End-shorting and electric field in edge plasmas with application to field-reversed configurations

    International Nuclear Information System (INIS)

    Steinhauer, Loren C.

    2002-01-01

    The shorting of open field lines where they intersect external boundaries strongly modifies the transverse electric field all along the field lines. The modified electric field is found by an extension of the familiar Boltzmann relation for the electric potential. This leads to a prediction of the electric drift. Flow generation by electrical shorting is applied here to three aspects of elongated field-reversed configurations: plasma rotation rate; the particle-loss spin-up mechanism; and the sustainability of the rotating magnetic field current drive method

  16. HPLC Analysis to Determine the Half-life and Bioavailability of the Termiticides Bifenthrin and Fipronil in Soil.

    Science.gov (United States)

    Manzoor, F; Pervez, M

    2017-12-05

    The aim of this study was to test the bioavailability and degradation in soil of the termiticides bifenthrin and fipronil, which are used to treat subterranean termites (Heterotermes indicola, Wasmann). Soil collected from different areas of Lahore was categorized as sandy clay loam (SCL) or sandy loam (SL). Laboratory bioassays were conducted to determine the bioavailability ratio of bifenthrin and fipronil in each type of soil after different periods of time. LT50 values were determined posttreatment at different time intervals. Regarding soil type, both termiticides were more effective in SL soil, compared with SCL soil posttreatment. There were significant differences in termite mortality in treated compared with untreated control samples (P bifenthrin (maximum, 1,002 and 1,262 d in SCL soil and SL soil, respectively) indicated that it persisted in both soil types at all concentrations. The maximum calculated half-life values of fipronil were 270 and 555 d in SCL and SL soil, respectively. At lower concentrations and over longer periods of time, fipronil completely degraded in SL soil, while a negligible amount was detected in SCL soil. Termiticide concentration decreased over time, as did the termiticide recovery rate. Overall, bifenthrin was more persistent than fipronil under all treatment conditions tested. © The Author(s) 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  17. Degradation and half-life of DNA present in biomass from a genetically-modified organism during land application.

    Science.gov (United States)

    Halter, Mathew C; Zahn, James A

    2017-02-01

    White biotechnology has made a positive impact on the chemical industry by providing safer, more efficient chemical manufacturing processes that have reduced the use of toxic chemicals, harsh reaction conditions, and expensive metal catalysts, which has improved alignment with the principles of Green Chemistry. The genetically-modified (GM) biocatalysts that are utilized in these processes are typically separated from high-value products and then recycled, or eliminated. Elimination routes include disposal in sanitary landfills, incineration, use as a fuel, animal feed, or reuse as an agricultural soil amendment or other value-added products. Elimination routes that have the potential to impact the food chain or environment have been more heavily scrutinized for the fate and persistence of biological products. In this study, we developed and optimized a method for monitoring the degradation of strain-specific DNA markers from a genetically-modified organism (GMO) used for the commercial production of 1,3-propanediol. Laboratory and field tests showed that a marker for heterologous DNA in the GM organism was no longer detectable by end-point polymerase chain reaction (PCR) after 14 days. The half-life of heterologous DNA was increased by 17% (from 42.4 to 49.7 h) after sterilization of the soil from a field plot, which indicated that abiotic factors were important in degradation of DNA under field conditions. There was no evidence for horizontal transfer of DNA target sequences from the GMO to viable organisms present in the soil.

  18. Dependence of Rn adsorption rate and effective half-life time on diffusion barrier type and moving air environment

    International Nuclear Information System (INIS)

    Arafa, Wafaa; Badran, Heba

    2005-01-01

    The variation of the adsorbed radon rate during the exposure time using charcoal canister was studied applying moving air environment inside the radon chamber and compared to the static air measurements. The air movement increases the accumulation time leading to more accurate results. Different types of membrane have been tested as diffusion barrier for activated charcoal canisters. The Makrofol and aluminized polycarbonate improve the adsorption/desorption rate more than the polyehylene membrane. The measured effective half-life time showed a remarkable correlation with the previously measured permeability constant for corresponding membranes. Different types of commercially available charcoal were investigated to develop a local version of charcoal canister for radon measurements. Applying static and moving air environments, the break point and radon collection efficiency were determined at different temperatures. Both of the temperature and air movement accelerate the appearance of the break point. Th efficiency of the locally developed charcoal is 87% and 84.5% of that Calgon PCB charcoal used by EPA. (author)

  19. Diffusion and release of noble gas and halogen fission products with several days half-life in UO2 particle

    International Nuclear Information System (INIS)

    Fang Chao

    2013-01-01

    The exact solutions of diffusion and release model of noble gas and halogen fission products in UO 2 particle of HTGR were built under the conditions of adsorption effect and other physical processes. The corresponding release fractions (F(t)) and the ratio of release and productive amounts (R(t)/B (t)) of fission products were also derived. Furthermore, the F(t) and R(t)/B(t) of 131 I, 131 IXe m , 133 Xe and 133 Xe m whose half-lifes are several days in UO 2 particle with the exact solutions, approximate solutions and corresponding numerical solutions under different temperature histories of reactor core were investigated. The results show that the F(t) and R(t)/B(t) are different in numerical values unless the time of release is long enough. The properties of conservation of exact solutions are much more reasonable than the ones of approximate solutions. It is also found that the results of exact solutions approach the actual working conditions more than the approximate and numerical solutions. (author)

  20. Developments in human growth hormone preparations: sustained-release, prolonged half-life, novel injection devices, and alternative delivery routes

    Directory of Open Access Journals (Sweden)

    Cai Y

    2014-07-01

    Full Text Available Yunpeng Cai,1,2 Mingxin Xu,2 Minglu Yuan,2 Zhenguo Liu,1 Weien Yuan2 1Department of Neurology, Xinhua Hospital, School of Medicine, 2School of Pharmacy, Shanghai Jiao Tong University, Shanghai, People’s Republic of China Abstract: Since the availability of recombinant human growth hormone (rhGH enabled the application of human growth hormone both in clinical and research use in the 1980s, millions of patients were prescribed a daily injection of rhGH, but noncompliance rates were high. To address the problem of noncompliance, numerous studies have been carried out, involving: sustained-release preparations, prolonged half-life derivatives, new injectors that cause less pain, and other noninvasive delivery methods such as intranasal, pulmonary and transdermal deliveries. Some accomplishments have been made and launched already, such as the Nutropin Depot® microsphere and injectors (Zomajet®, Serojet®, and NordiFlex®. Here, we provide a review of the different technologies and illustrate the key points of these studies to achieve an improved rhGH product. Keywords: intranasal, pulmonary, transdermal, microsphere, microneedle, hydrogel

  1. Half-life, branching-ratio, and Q-value measurement for the superallowed 0+→0+β+ emitter 42Ti

    International Nuclear Information System (INIS)

    Nieto, T. Kurtukian; Souin, J.; Audirac, L.; Blank, B.; Giovinazzo, J.; Eronen, T.; Aeystoe, J.; Elomaa, V.-V.; Hager, U.; Hakala, J.; Jokinen, A.; Kankainen, A.; Karvonen, P.; Kessler, T.; Moore, I. D.; Penttilae, H.; Rahaman, S.; Reponen, M.; Rissanen, J.; Saastamoinen, A.

    2009-01-01

    The half-life, the branching ratio, and the decay Q value of the superallowed β emitter 42 Ti were measured in an experiment performed at the JYFLTRAP facility of the Accelerator Laboratory of the University of Jyvaeskylae. 42 Ti is the heaviest T z =-1 nucleus for which high-precision measurements of these quantities have been tried. The half-life (T 1/2 =208.14±0.45 ms) and the Q value [Q EC =7016.83(25) keV] are close to or reach the required precision of about 0.1%. The branching ratio for the superallowed decay branch [BR=47.7(12)%], a by-product of the half-life measurement, does not reach the necessary precision yet. Nonetheless, these results allow one to determine the experimental ft value and the corrected Ft value to be 3114(79) and 3122(79) s, respectively.

  2. Apo AIV and Citrulline Plasma Concentrations in Short Bowel Syndrome Patients: The Influence of Short Bowel Anatomy

    Science.gov (United States)

    Targarona, Jordi; Ruiz, Jorge; García, Natalia; Oró, Denise; García-Villoria, Judit; Creus, Gloria; Pita, Ana M.

    2016-01-01

    Introduction Parenteral nutrition (PN) dependence in short bowel syndrome (SBS) patients is linked to the functionality of the remnant small bowel (RSB). Patients may wean off PN following a period of intestinal adaptation that restores this functionality. Currently, plasma citrulline is the standard biomarker for monitoring intestinal functionality and adaptation. However, available studies reveal that the relationship the biomarker with the length and function of the RSB is arguable. Thus, having additional biomarkers would improve pointing out PN weaning. Aim By measuring concomitant changes in citrulline and the novel biomarker apolipoprotein AIV (Apo AIV), as well as taking into account the anatomy of the RSB, this exploratory study aims to a better understanding of the intestinal adaptation process and characterization of the SBS patients under PN. Methods Thirty four adult SBS patients were selected and assigned to adapted (aSBS) and non-adapted (nSBS) groups after reconstructive surgeries. Remaining jejunum and ileum lengths were recorded. The aSBS patients were either on an oral diet (ORAL group), those with intestinal insufficiency, or on oral and home parenteral nutrition (HPN group), those with chronic intestinal failure. Apo AIV and citrulline were analyzed in plasma samples after overnight fasting. An exploratory ROC analysis using citrulline as gold standard was performed. Results Biomarkers, Apo AIV and citrulline showed a significant correlation with RSBL in aSBS patients. In jejuno-ileocolic patients, only Apo AIV correlated with RSBL (rb = 0.54) and with ileum length (rb = 0.84). In patients without ileum neither biomarker showed any correlation with RSBL. ROC analysis indicated the Apo AIV cut-off value to be 4.6 mg /100 mL for differentiating between the aSBS HPN and ORAL groups. Conclusions Therefore, in addition to citrulline, Apo AIV can be set as a biomarker to monitor intestinal adaptation in SBS patients. As short bowel anatomy is shown

  3. Dietary Zinc Intake and Plasma Zinc Concentrations in Children with Short Stature and Failure to Thrive.

    Science.gov (United States)

    Yazbeck, Nadine; Hanna-Wakim, Rima; El Rafei, Rym; Barhoumi, Abir; Farra, Chantal; Daher, Rose T; Majdalani, Marianne

    2016-01-01

    The burden of zinc deficiency on children includes an increased incidence of diarrhea, failure to thrive (FTT) and short stature. The aim of this study was to assess whether children with FTT and/or short stature have lower dietary zinc intake and plasma zinc concentrations compared to controls. A case-control study conducted at the American University of Beirut Medical Center included 161 subjects from 1 to 10 years of age. Cases had a statistically significant lower energy intake (960.9 vs. 1,135.2 kcal for controls, p = 0.010), lower level of fat (30.3 vs. 36.5 g/day, p = 0.0043) and iron intake (7.4 vs. 9.1 mg/day, p = 0.034). There was no difference in zinc, copper, carbohydrate and protein intake between the 2 groups. The plasma zinc concentration did not differ between the cases and controls (97.4 vs. 98.2 μg/dl, p = 0.882). More cases had mild-to-moderate zinc deficiency when compared to controls with 10.3 vs. 3.6%, p = 0.095. Our study did not show statistically significant difference in dietary zinc intake and plasma zinc concentrations between children with FTT and/or short stature compared to healthy controls. A prospective study is planned to assess the effect of zinc supplementation on growth parameters in FTT children. © 2016 S. Karger AG, Basel.

  4. Analysis of existing data and specification of an experiment to determine the 252Cf half-life to the required degree of accuracy

    International Nuclear Information System (INIS)

    Lorenz, A.; Kharitonov, I.A.

    1994-02-01

    The methods used and the results obtained in measurements of the 252 Cf half-life are analyzed. In calculating the weighted mean value, additional error components as well as those given by the authors are taken into account. In order to reduce the error in the weighted mean value to less than 0.1%, the need and the requirements for an exact measurement are specified. A half-life of 2.6473±0.0028 years is recommended. (author). 16 refs, 3 tabs

  5. High-precision half-life measurements of the T=1/2 mirror beta decays F-17 and Cl-33

    OpenAIRE

    Grinyer, J; Grinyer, G. F; Babo, Mathieu; Bouzomita, H; Chauveau, P; Delahaye, P; Dubois, M; Frigot, R; Jardin, P; Leboucher, C; Maunoury, L; Seiffert, C; Thomas, J. C; Traykov, E

    2015-01-01

    Background: Measurements of the ft values for T=1/2 mirror β+ decays offer a method to test the conserved vector current hypothesis and to determine Vud, the up-down matrix element of the Cabibbo-Kobayashi-Maskawa matrix. In most mirror decays used for these tests, uncertainties in the ft values are dominated by the uncertainties in the half-lives. Purpose: Two precision half-life measurements were performed for the T=1/2β+ emitters, 17F and 33Cl, in order to eliminate the half-life as th...

  6. High-precision half-life measurements of the T=1/2 mirror β decays F17 and Cl33

    OpenAIRE

    Grinyer, J; Grinyer, G F; Babo, M; Bouzomita, H; Chauveau, P; Delahaye, P; Dubois, M; Frigot, R; Jardin, P; Leboucher, C; Maunoury, L; Seiffert, C; Thomas, J C; Traykov, E

    2015-01-01

    Background: Measurements of the ft values for T=1/2 mirror β+ decays offer a method to test the conserved vector current hypothesis and to determine Vud, the up-down matrix element of the Cabibbo-Kobayashi-Maskawa matrix. In most mirror decays used for these tests, uncertainties in the ft values are dominated by the uncertainties in the half-lives. Purpose: Two precision half-life measurements were performed for the T=1/2β+ emitters, F17 and Cl33, in order to eliminate the half-life as the le...

  7. A Two-pronged Binding Mechanism of IgG to the Neonatal Fc Receptor Controls Complex Stability and IgG Serum Half-life

    DEFF Research Database (Denmark)

    Jensen, Pernille Foged; Schoch, Angela; Larraillet, Vincent

    2017-01-01

    The success of recombinant monoclonal immunoglobulins (IgG) is rooted in their ability to target distinct antigens with high affinity combined with an extraordinarily long serum half-life, typically around 3 weeks. The pharmacokinetics of IgGs is intimately linked to the recycling mechanism...... half-life of ∼8 days. Here we dissect the molecular origins of excessive FcRn binding in therapeutic IgGs using a combination of hydrogen/deuterium exchange mass spectrometry and FcRn affinity chromatography. We provide experimental evidence for a two-pronged IgG-FcRn binding mechanism involving direct...

  8. Ceramide binding to anandamide increases its half-life and potentiates its cytotoxicity in human neuroblastoma cells.

    Science.gov (United States)

    Di Scala, Coralie; Mazzarino, Morgane; Yahi, Nouara; Varini, Karine; Garmy, Nicolas; Fantini, Jacques; Chahinian, Henri

    2017-06-01

    Anandamide (AEA) is a ubiquitous lipid that exerts neurotransmitter functions but also controls important biological functions such as proliferation, survival, or programmed cell death. The latter effects are also regulated by ceramide, a lipid enzymatically generated from sphingomyelin hydrolysis by sphingomyelinase. Ceramide has been shown to increase the cellular toxicity of AEA, but the mechanisms controlling this potentiating effect remained unclear. Here we have used a panel of in silico, physicochemical, biochemical and cellular approaches to study the crosstalk between AEA and ceramide apoptotic pathways. Molecular dynamics simulations indicated that AEA and ceramide could form a stable complex in phosphatidylcholine membranes. Consistent with these data, we showed that AEA can specifically insert into ceramide monolayers whereas it did not penetrate into sphingomyelin membranes. Then we have studied the effects of ceramide on AEA-induced toxicity of human neuroblastoma cells. In these experiments, the cells have been either naturally enriched in ceramide by neutral sphingomyelinase pre-incubation or treated with C2-ceramide, a biologically active ceramide analog. Both treatments significantly increased the cytotoxicity of AEA as assessed by the MTS mitochondrial toxicity assay. This effect was correlated with the concomitant accumulation of natural ceramide (or its synthetic analog) and AEA in the cells. A kinetic study of AEA hydrolysis showed that ceramide inhibited the fatty acid amino hydrolase (FAAH) activity in cell extracts. Taken together, these data suggested that ceramide binds to AEA, increases its half-life and potentiates its cytotoxicity. Overall, these mechanisms account for a functional cross-talk between AEA and ceramide apoptotic pathways. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Measurement of the half-life of 60Fe using the Argonne FN tandem-superconducting Linac system as an accelerator mass spectrometer

    International Nuclear Information System (INIS)

    Kutschera, W.; Billquist, P.J.; Frekers, D.

    1983-01-01

    An experiment to improve the accuracy in the half-life value of 60 Fe by measuring both the amount of 60 Fe nuclei and the decay-rate of a spallation produced sample using the relation dN/dt = -lambda N is briefly discussed

  10. New limit on the half-life of 78Kr with respect to the 2K(2ν)-capture decay mode

    International Nuclear Information System (INIS)

    Gavriljuk, Ju.M.; Kuzminov, V.V.; Osetrova, N.Ya.; Ratkevich, S.S.

    2000-01-01

    The features of data accumulated for 1817 h in an experimental search for the 2K(2ν)-capture mode of 78 Kr decay are discussed. A new limit on the half-life for this decay is found: T 1sol2 ≥ 2.3 x 10 20 yr (at a 90% C.L.)

  11. Platelet half-life in patients with primary hyperlipoproteinemia type IIa, IIb, and IV according to Fredrickson with and without clinical signs of atherosclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Jaeger, E; Sinzinger, H; Widhalm, K; Kaliman, J; Hoefer, R [Vienna Univ. (Austria). 2. Medizinische Klinik; Ludwig Boltzmann-Institut fuer Nuklearmedizin, Vienna (Austria); Vienna Univ. (Austria). Kinderklinik; Vienna Univ. (Austria). Kardiologische Klinik)

    1982-09-01

    It is generally accepted that platelet half-life is shortened in atherosclerotic vascular diseases. Concerning changes due to hyperlipoproteinemia (HLP), however, there exist only few data. Therefore, we examined the platelet-half life in 60 patients with recently discovered HLP type IIa, IIb and IV according to Fredrickson before treatment in comparison to 60 controls. 33 of the HLP-patients had no clinical symptoms of angiopathy. 27 patients suffered from peripheral vascular disease or from coronary heart disease as verified by angiography. The labelling of autologous platelets was performed with 100..mu..Ci of /sup 111/Indium-oxine-sulfate at 37/sup 0/C for 5 minutes. The mean labelling efficiency was 90%, the recovery after 2 hours about 70%. Serum lipoproteins were estimated by means of ultracentrifugation and polyanionprecipitation according to Lipid Research Clinic Methods. In the patients with HLP platelet half-life was significantly shortened in comparison to the control group (p < 0.01). These changes were most pronounced in patients with HLP-type IIa and with atherosclerotic lesions, respectively. In patients with HLP-type IIa a very close correlation could be demonstrated between platelet half-life and LDL-cholesterol (r = -0.72; p < 0.001) as well as total cholesterol (r = -0.73; p < 0.001). These data prove that in HLP in-vivo platelet function as measured by platelet survival is significantly influenced even before the occurrence of clinically relevant symptoms of atherosclerosis.

  12. Resonant third-harmonic generation of a short-pulse laser from electron-hole plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Kant, Niti [Department of Physics, Lovely Professional University, Phagwara, Punjab 144 402 (India); Nandan Gupta, Devki [Department of Physics and Astrophysics, University of Delhi, Delhi 110 007 (India); Suk, Hyyong [Advanced Photonics Research Institute (APRI) and Graduate Program of Photonics and Applied Physics, Gwangju Institute of Science and Technology, Gwangju 500 712 (Korea, Republic of)

    2012-01-15

    In semiconductors, free carriers are created in pairs in inter-band transitions and consist of an electron and its corresponding hole. At very high carrier densities, carrier-carrier collisions dominate over carrier-lattice collisions and carriers begin to behave collectively to form plasma. Here, we apply a short-pulse laser to generate third-harmonic radiation from a semiconductor plasma (electron-hole plasma) in the presence of a transverse wiggler magnetic-field. The process of third-harmonic generation of an intense short-pulse laser is resonantly enhanced by the magnetic wiggler, i.e., wiggler magnetic field provides the necessary momentum to third-harmonic photons. In addition, a high-power laser radiation, propagating through a semiconductor imparts an oscillatory velocity to the electrons and exerts a ponderomotive force on electrons at the third-harmonic frequency of the laser. This oscillatory velocity produces a third-harmonic longitudinal current. And due to the beating of the longitudinal electron velocity and the wiggler magnetic field, a transverse third-harmonic current is produced that drives third-harmonic electromagnetic radiation. It is finally observed that for a specific wiggler wave number value, the phase-matching conditions for the process are satisfied, leading to resonant enhancement in the energy conversion efficiency.

  13. Resonant third-harmonic generation of a short-pulse laser from electron-hole plasmas

    International Nuclear Information System (INIS)

    Kant, Niti; Nandan Gupta, Devki; Suk, Hyyong

    2012-01-01

    In semiconductors, free carriers are created in pairs in inter-band transitions and consist of an electron and its corresponding hole. At very high carrier densities, carrier-carrier collisions dominate over carrier-lattice collisions and carriers begin to behave collectively to form plasma. Here, we apply a short-pulse laser to generate third-harmonic radiation from a semiconductor plasma (electron-hole plasma) in the presence of a transverse wiggler magnetic-field. The process of third-harmonic generation of an intense short-pulse laser is resonantly enhanced by the magnetic wiggler, i.e., wiggler magnetic field provides the necessary momentum to third-harmonic photons. In addition, a high-power laser radiation, propagating through a semiconductor imparts an oscillatory velocity to the electrons and exerts a ponderomotive force on electrons at the third-harmonic frequency of the laser. This oscillatory velocity produces a third-harmonic longitudinal current. And due to the beating of the longitudinal electron velocity and the wiggler magnetic field, a transverse third-harmonic current is produced that drives third-harmonic electromagnetic radiation. It is finally observed that for a specific wiggler wave number value, the phase-matching conditions for the process are satisfied, leading to resonant enhancement in the energy conversion efficiency.

  14. Experimental investigation of plasma dynamics in dc and short-pulse magnetron discharges

    International Nuclear Information System (INIS)

    Seo, Sang-Hun; In, Jung-Hwan; Chang, Hong-Young

    2006-01-01

    The spatiotemporal evolution of the electron energy distribution function (EEDF) and of plasma parameters such as the electron density, the electron temperature and the plasma and floating potentials has been investigated using spatially and temporally resolved single Langmuir probe measurements in dc and mid-frequency, short-pulse magnetron discharges with a repetition frequency of 10 kHz and a duty cycle of 10%. In the pulsed discharge of the short duty cycle, a peak electron temperature higher than 10 eV was observed near the cathode fall region during the early phase of the pulse-on, which is about three times higher than the steady-state value of the electron temperature in the dc discharge. The temporal evolution of the measured EEDFs showed the initial efficient electron heating during the early phase of the pulse-on and the subsequent relaxation of electron energy by the inelastic collisions and the diffusive loss. The high-energy electrons generated during the pulse-on phase diffused the downstream region toward the grounded substrate, resulting in a bi-Maxwellian EEDF consisting of the background low-energy electrons and the high-energy electrons. The results of the spatially and temporally resolved probe measurements will be presented and the enhanced efficiency of the electron heating in the short-pulse discharge will be explained on the basis of the global model of a pulsed discharge

  15. A new value for the half-life of {sup 10}Be by Heavy-Ion Elastic Recoil Detection and liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Korschinek, G., E-mail: Gunther.Korschinek@ph.tum.d [Physik Department, Technische Universitaet Muenchen, D-85748 Garching (Germany); Bergmaier, A. [Universitaet der Bundeswehr Muenchen, Fakultaet fuer Luft- und Raumfahrttechnik, Institut fuer Angewandte Physik und Messtechnik LRT2, Werner-Heisenberg-Weg 39, D-85577 Neubiberg (Germany); Faestermann, T. [Physik Department, Technische Universitaet Muenchen, D-85748 Garching (Germany); Gerstmann, U.C. [Helmholtz Zentrum Muenchen, German Research Center for Environmental Health, Institute of Radiation Protection, Ingolstaedter Landstr. 1, D-85764 Neuherberg (Germany); Knie, K.; Rugel, G. [Physik Department, Technische Universitaet Muenchen, D-85748 Garching (Germany); Wallner, A. [VERA Laboratory, Faculty of Physics, University of Vienna, Waehringer Strasse 17, A-1090 Wien (Austria); Dillmann, I. [Physik Department, Technische Universitaet Muenchen, D-85748 Garching (Germany); Dollinger, G. [Universitaet der Bundeswehr Muenchen, Fakultaet fuer Luft- und Raumfahrttechnik, Institut fuer Angewandte Physik und Messtechnik LRT2, Werner-Heisenberg-Weg 39, D-85577 Neubiberg (Germany); Lierse von Gostomski, Ch. [Lehrstuhl fuer Radiochemie, Technische Universitaet Muenchen, D-85748 Garching (Germany); Kossert, K. [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany); Maiti, M.; Poutivtsev, M. [Physik Department, Technische Universitaet Muenchen, D-85748 Garching (Germany); Remmert, A. [Lehrstuhl fuer Radiochemie, Technische Universitaet Muenchen, D-85748 Garching (Germany)

    2010-01-15

    The importance of {sup 10}Be in different applications of accelerator mass spectrometry (AMS) is well-known. In this context the half-life of {sup 10}Be has a crucial impact, and an accurate and precise determination of the half-life is a prerequisite for many of the applications of {sup 10}Be in cosmic-ray and earth science research. Recently, the value of the {sup 10}Be half-life has been the centre of much debate. In order to overcome uncertainties inherent in previous determinations, we introduced a new method of high accuracy and precision. An aliquot of our highly enriched {sup 10}Be master solution was serially diluted with increasing well-known masses of {sup 9}Be. We then determined the initial {sup 10}Be concentration by least square fit to the series of measurements of the resultant {sup 10}Be/{sup 9}Be ratio. In order to minimize uncertainties because of mass bias which plague other low-energy mass spectrometric methods, we used for the first time Heavy-Ion Elastic Recoil Detection (HI-ERD) for the determination of the {sup 10}Be/{sup 9}Be isotopic ratios, a technique which does not suffer from difficult to control mass fractionation. The specific activity of the master solution was measured by means of accurate liquid scintillation counting (LSC). The resultant combination of the {sup 10}Be concentration and activity yields a {sup 10}Be half-life of T{sub 1/2} = 1.388 +- 0.018 (1 s, 1.30%) Ma. In a parallel but independent study (Chmeleff et al. ), found a value of 1.386 +- 0.016 (1.15%) Ma. Our recommended weighted mean and mean standard error for the new value for {sup 10}Be half-life based on these two independent measurements is 1.387 +- 0.012 (0.87%) Ma.

  16. Plasma processes in water under effect of short duration pulse discharges

    Science.gov (United States)

    Gurbanov, Elchin

    2013-09-01

    It is very important to get a clear water without any impurities and bacteria by methods, that don't change the physical and chemical indicators of water now. In this article the plasma processes during the water treatment by strong electric fields and short duration pulse discharges are considered. The crown discharge around an electrode with a small radius of curvature consists of plasma leader channels with a high conductivity, where the thermo ionization processes and UV-radiation are taken place. Simultaneously the partial discharges around potential electrode lead to formation of atomic oxygen and ozone. The spark discharge arises, when plasma leader channels cross the all interelectrode gap, where the temperature and pressure are strongly grown. As a result the shock waves and dispersing liquid streams in all discharge gap are formed. The plasma channels extend, pressure inside it becomes less than hydrostatic one and the collapse and UV-radiation processes are started. The considered physical processes can be successfully used as a basis for development of pilot-industrial installations for conditioning of drinking water and to disinfecting of sewage.

  17. Unresolved spectral structures emitted from heavy atom plasmas produced by short pulse laser

    International Nuclear Information System (INIS)

    Fraenkel, M.; Zigler, A.

    1999-01-01

    Spectra of rare earth elements emitted from ultra short pulse laser produced plasma were recorded using simultaneously high and low resolution, spectrometers. A study of the broad band emission of the Δn = 1 transitions in highly ionized Ba and Sm plasma showed that this band is completely unresolved. The spectra were analyzed using the LTE based on super-transition array (STA) model. The theory reconstructs the entire Ba spectrum using a single temperature and density, whereas for Sm the discrepancies between the theory and experiment are not reconcilable. The agreement in the Ba case is attributed to the fact that BaF 2 target is transparent to the laser's prepulse effects, producing a homogeneous dense plasma, whereas for Sm the dilute plasma created by the prepulse is far from LTE. The obtained results posses a significant implication to the applicability of the STA model, in particular for calculations of opacities and conversion of laser light to X-rays. (orig.)

  18. Unresolved spectral structures emitted from heavy atom plasmas produced by short pulse laser

    Energy Technology Data Exchange (ETDEWEB)

    Fraenkel, M.; Zigler, A. [Hebrew Univ., Jerusalem (Israel). Racah Inst. of Physics; Bar-Shalom, A.; Oreg, J. [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev; Faenov, A.Ya.; Pikuz, T.A. [Multicharged Ions Spectra Data Center of VNIIFTRI, Russian Committee of Standards Moscow region (Russian Federation)

    1999-09-01

    Spectra of rare earth elements emitted from ultra short pulse laser produced plasma were recorded using simultaneously high and low resolution, spectrometers. A study of the broad band emission of the {delta}n = 1 transitions in highly ionized Ba and Sm plasma showed that this band is completely unresolved. The spectra were analyzed using the LTE based on super-transition array (STA) model. The theory reconstructs the entire Ba spectrum using a single temperature and density, whereas for Sm the discrepancies between the theory and experiment are not reconcilable. The agreement in the Ba case is attributed to the fact that BaF{sub 2} target is transparent to the laser's prepulse effects, producing a homogeneous dense plasma, whereas for Sm the dilute plasma created by the prepulse is far from LTE. The obtained results posses a significant implication to the applicability of the STA model, in particular for calculations of opacities and conversion of laser light to X-rays. (orig.)

  19. Effective Half-life of I-131 in Patients with Differentiated Thyroid Cancer Treated by Radioactive I-131

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seok Gun [Dankook University, Cheonan (Korea, Republic of)

    2008-12-15

    Effective half life of I-131 (T{sub eff}) in patients with differentiated thyroid cancer treated by I-131 is must-know value for dose calculation and determination of release time from isolation room. There has been no report about T{sub eff} in Koreans. Thus, author tried to measure dose rate without radiation exposure to faculty members and calculated T{sub eff}. Probe of radiation survey meter was fixed at the wall of isolation room, and body of survey meter was placed outside the room. With this simple arrangement, author could measure radiation frequently without radiation exposure to faculty members in 68 patient (F=55, M=13, age=47{+-}13.7) treated by I-131 (3.7{approx}7.4 GBq) for differentiated thyroid cancer from Jan 2006 to Dec 2006. From this data, T{sub eff}, 48 hr retention rate, and the time necessary to whole body retention of I-131 become less than 1.1 GBq were calculated. Serum creatinine levels were measured before and after thyroid hormone withdrawal. T{sub eff} was 15.4{+-}4.3 hr (9.4{approx}32.5 hr). There was a loose correlation between T{sub eff} and serum creatinine concentration (r=0.45). 48hr retention was 4.9{+-}4.2% (1{approx}23%). Time necessary to whole body retention of I-131 become less than 1.1 GBq was calculated as 47.1{+-}13.2 hr for 9.25 GBq, 42.1{+-}11.9 hr for 7.4 GBq, 35.7{+-}10.0 hr for 5.55 GBq, and 26.7{+-}7.5 hr for 3.7 GBq dose of I-131. Author successfully measured radiation dose rates in isolated patients treated by high dose of I-131 without radiation exposure to the faculty members with simple arrangement of survey meter probe. Using those data, T{sub eff} and some other indices were calculated.

  20. Determining thyroid {sup 131}I effective half-life for the treatment planning of Graves' disease

    Energy Technology Data Exchange (ETDEWEB)

    Willegaignon, Jose; Sapienza, Marcelo T.; Barberio Coura Filho, George; Buchpiguel, Carlos A. [Cancer Institute of Sao Paulo State (ICESP), Clinical Hospital, School of Medicine, University of Sao Paulo, Sao Paulo 01246-000 (Brazil); Nuclear Medicine Service, Department of Radiology, School of Medicine, University of Sao Paulo, Sao Paulo 01246-000 (Brazil); Traino, Antonio C. [Unit of Medical Physics, Azienda Ospedaliero-Universitaria Pisana, Pisa 56126 (Italy)

    2013-02-15

    Purpose: Thyroid {sup 131}I effective half-life (T{sub eff}) is an essential parameter in patient therapy when accurate radiation dose is desirable for producing an intended therapeutic outcome. Multiple {sup 131}I uptake measurements and resources from patients themselves and from nuclear medicine facilities are requisites for determining T{sub eff}, these being limiting factors when implementing the treatment planning of Graves' disease (GD) in radionuclide therapy. With the aim of optimizing this process, this study presents a practical, propitious, and accurate method of determining T{sub eff} for dosimetric purposes. Methods: A total of 50 patients with GD were included in this prospective study. Thyroidal {sup 131}I uptake was measured at 2-h, 6-h, 24-h, 48-h, 96-h, and 220-h postradioiodine administration. T{sub eff} was calculated by considering sets of two measured points (24-48-h, 24-96-h, and 24-220-h), sets of three (24-48-96-h, 24-48-220-h, and 24-96-220-h), and sets of four (24-48-96-220-h). Results: When considering all the measured points, the representative T{sub eff} for all the patients was 6.95 ({+-}0.81) days, whereas when using such sets of points as (24-220-h), (24-96-220-h), and (24-48-220-h), this was 6.85 ({+-}0.81), 6.90 ({+-}0.81), and 6.95 ({+-}0.81) days, respectively. According to the mean deviations 2.2 ({+-}2.4)%, 2.1 ({+-}2.0)%, and 0.04 ({+-}0.09)% found in T{sub eff}, calculated based on all the measured points in time, and with methods using the (24-220-h), (24-48-220-h), and (24-96-220-h) sets, respectively, no meaningful statistical difference was noted among the three methods (p > 0.500, t test). Conclusions: T{sub eff} obtained from only two thyroid {sup 131}I uptakes measured at 24-h and 220-h, besides proving to be sufficient, accurate enough, and easily applicable, attributes additional major cost-benefits for patients, and facilitates the application of the method for dosimetric purposes in the treatment planning of

  1. Compressing and focusing a short laser pulse by a thin plasma lens

    International Nuclear Information System (INIS)

    Ren, C.; Duda, B. J.; Hemker, R. G.; Mori, W. B.; Katsouleas, T.; Antonsen, T. M.; Mora, P.

    2001-01-01

    We consider the possibility of using a thin plasma slab as an optical element to both focus and compress an intense laser pulse. By thin we mean that the focal length is larger than the lens thickness. We derive analytic formulas for the spot size and pulse length evolution of a short laser pulse propagating through a thin uniform plasma lens. The formulas are compared to simulation results from two types of particle-in-cell code. The simulations give a greater final spot size and a shorter focal length than the analytic formulas. The difference arises from spherical aberrations in the lens which lead to the generation of higher-order vacuum Gaussian modes. The simulations also show that Raman side scattering can develop. A thin lens experiment could provide unequivocal evidence of relativistic self-focusing

  2. Nonlinear interaction of powerful short electromagnetic pulses with an electron plasma

    International Nuclear Information System (INIS)

    Rao, N.N.; Yu, M.Y.; Shukla, P.K.

    1990-01-01

    The nonlinear interaction of powerful short electromagnetic pulses with a plasma consisting of two groups of electrons and immobile ions has been studied. It is shown that the interaction is governed by a nonlinear equation for the electromagnetic wave envelope and a driven nonlinear equation for the low-frequency electron fluctuations. The driver for the latter depends explicitly on the spatio-temporal evolution of the electromagnetic wave flux. It is found that, depending on the cold-to-hot electron density ratio, the localized pulse can propagate with sub- as well as supersonic velocities accompanied by compressional or rarefactional density perturbations. The conditions of existence for the different types of solitary pulses are obtained. The present investigation may be relevant to the study of wave-plasma interaction devices such as inertial fusion confinement as well as to ionospheric modification experiments. (author)

  3. Enhancement and stabilization of plasma using collinear long-short double-pulse laser-induced breakdown spectroscopy

    Science.gov (United States)

    Cui, Minchao; Deguchi, Yoshihiro; Wang, Zhenzhen; Fujita, Yuki; Liu, Renwei; Shiou, Fang-Jung; Zhao, Shengdun

    2018-04-01

    A collinear long-short dual-pulse laser-induced breakdown spectroscopy (DP-LIBS) method was employed to enhance and stabilize the laser-induced plasma from steel sample. The long-pulse-width laser beam with the pulse width of 60 μs was generated by a Nd: YAG laser which was operated at FR (free running) mode. The comparative experiments were carried out between single pulse LIBS (SP-LIBS) and long-short DP-LIBS. The recorded results showed that the emission intensities and the temperature of plasma were enhanced by long-short DP-LIBS. The plasma images showed that the plasma was bigger and had a longer lifetime in long-short DP-LIBS situation. Through the calculation of time-resolved plasma temperature and intensity ratio, it can be concluded that the plasma was stabilized by the long-pulse-width laser beam. The long-short DP-LIBS method also generated the stable plasma condition from the samples with different initial temperatures, which overcame the difficulties of LIBS in the online measurement for steel production line.

  4. An imaging proton spectrometer for short-pulse laser plasma experiments

    International Nuclear Information System (INIS)

    Chen Hui; Hazi, A. U.; Maren, R. van; Chen, S. N.; Le Pape, S.; Rygg, J. R.; Shepherd, R.; Fuchs, J.; Gauthier, M.

    2010-01-01

    The ultraintense short pulse laser pulses incident on solid targets can generate energetic protons. In addition to their potentially important applications such as in cancer treatments and proton fast ignition, these protons are essential to understand the complex physics of intense laser plasma interaction. To better characterize these laser-produced protons, we designed and constructed a novel spectrometer that will not only measure proton energy distribution with high resolution but also provide its angular characteristics. The information obtained from this spectrometer compliments those from commonly used diagnostics including radiochromic film packs, CR39 nuclear track detectors, and nonimaging magnetic spectrometers. The basic characterizations and sample data from this instrument are presented.

  5. An imaging proton spectrometer for short-pulse laser plasma experiments

    Energy Technology Data Exchange (ETDEWEB)

    Chen Hui; Hazi, A. U.; Maren, R. van; Chen, S. N.; Le Pape, S.; Rygg, J. R.; Shepherd, R. [Lawrence Livermore National Laboratory, Livemore, California 94551 (United States); Fuchs, J.; Gauthier, M. [LULI Ecole Polytechnique, 91128 Palaiseau Cedex (France)

    2010-10-15

    The ultraintense short pulse laser pulses incident on solid targets can generate energetic protons. In addition to their potentially important applications such as in cancer treatments and proton fast ignition, these protons are essential to understand the complex physics of intense laser plasma interaction. To better characterize these laser-produced protons, we designed and constructed a novel spectrometer that will not only measure proton energy distribution with high resolution but also provide its angular characteristics. The information obtained from this spectrometer compliments those from commonly used diagnostics including radiochromic film packs, CR39 nuclear track detectors, and nonimaging magnetic spectrometers. The basic characterizations and sample data from this instrument are presented.

  6. Towards a better prediction of peak concentration, volume of distribution and half-life after oral drug administration in man, using allometry.

    Science.gov (United States)

    Sinha, Vikash K; Vaarties, Karin; De Buck, Stefan S; Fenu, Luca A; Nijsen, Marjoleen; Gilissen, Ron A H J; Sanderson, Wendy; Van Uytsel, Kelly; Hoeben, Eva; Van Peer, Achiel; Mackie, Claire E; Smit, Johan W

    2011-05-01

    It is imperative that new drugs demonstrate adequate pharmacokinetic properties, allowing an optimal safety margin and convenient dosing regimens in clinical practice, which then lead to better patient compliance. Such pharmacokinetic properties include suitable peak (maximum) plasma drug concentration (C(max)), area under the plasma concentration-time curve (AUC) and a suitable half-life (t(½)). The C(max) and t(½) following oral drug administration are functions of the oral clearance (CL/F) and apparent volume of distribution during the terminal phase by the oral route (V(z)/F), each of which may be predicted and combined to estimate C(max) and t(½). Allometric scaling is a widely used methodology in the pharmaceutical industry to predict human pharmacokinetic parameters such as clearance and volume of distribution. In our previous published work, we have evaluated the use of allometry for prediction of CL/F and AUC. In this paper we describe the evaluation of different allometric scaling approaches for the prediction of C(max), V(z)/F and t(½) after oral drug administration in man. Twenty-nine compounds developed at Janssen Research and Development (a division of Janssen Pharmaceutica NV), covering a wide range of physicochemical and pharmacokinetic properties, were selected. The C(max) following oral dosing of a compound was predicted using (i) simple allometry alone; (ii) simple allometry along with correction factors such as plasma protein binding (PPB), maximum life-span potential or brain weight (reverse rule of exponents, unbound C(max) approach); and (iii) an indirect approach using allometrically predicted CL/F and V(z)/F and absorption rate constant (k(a)). The k(a) was estimated from (i) in vivo pharmacokinetic experiments in preclinical species; and (ii) predicted effective permeability in man (P(eff)), using a Caco-2 permeability assay. The V(z)/F was predicted using allometric scaling with or without PPB correction. The t(½) was estimated from

  7. Direct solution introduction using conventional nebulizers with a short torch for plasma mass spectrometry

    International Nuclear Information System (INIS)

    Westphal, Craig S.; Montaser, Akbar

    2006-01-01

    A new torch, a shortened version of a standard demountable torch, is proposed for facilitating direct injection of liquid samples into an inductively coupled plasma mass spectrometer using conventional and micro-pneumatic nebulizers. The proposed arrangement reduces the cost of the direct injector nebulizer by a factor of 5, typically from $2000 to $400, although a different torch is required. The analytical performance of the high efficiency nebulizer-short torch arrangement is compared to that obtained with the direct injection high efficiency nebulizer interfaced to the conventional torch. Optimum operating conditions for the high efficiency nebulizer-short torch arrangement are generally similar to those of the direct injection high efficiency nebulizer: high RF power (1500 W), low nebulizer gas flow rates (0.09 L/min) and low solution uptake rates (5-85 μL/min). Sensitivity with the high efficiency nebulizer-short torch system at 85 μL/min is improved by a factor of 2.4 on average compared to the direct injection high efficiency nebulizer, while precision values (%RSD) and detection limits are generally comparable or slightly degraded (on average by a factor of 1.7), respectively. Sensitivity is also better at lower solution uptake rates (5 μL/min) by factors ranging from 2 ( 82 Se) to 7 ( 59 Co) compared to the direct injection high efficiency nebulizer. Additionally, the %RSD values are better at 5 μL/min, ranging from 3.5% to 6.0% for the high efficiency nebulizer-short torch combination compared to 4.7 to 9.1% for the direct injection high efficiency nebulizer. The utility of the high efficiency nebulizer-short torch arrangement is demonstrated through the microscale flow injection analysis of Cr-DNA adducts and the analysis of four certified reference materials (Lyphochek urine metals control, SRM 1515: Apple Leaves, SRM 1570a: Spinach Leaves, SRM 1577b: Bovine Liver). Peak to peak precision values (N = 3) for the microscale flow injection analysis

  8. Changes in short-chain fatty acid plasma profile incurred by dietary fiber composition

    DEFF Research Database (Denmark)

    Knudsen, Knud Erik Bach; Jørgensen, Henry Johs. Høgh; Theil, Peter Kappel

    2016-01-01

    Pigs were used as model for humans to study the impact of dietary fiber (DF), the main substrate for microbial fermentation, on plasma profile of short-chain fatty acids (SCFA; acetate, propionate, and butyrate). Six female pigs fitted with catheters in the portal vein and mesenteric artery and w...... higher net absorption of butyrate (2.4–4.0 vs. 1.6 mmol/h; P ...Pigs were used as model for humans to study the impact of dietary fiber (DF), the main substrate for microbial fermentation, on plasma profile of short-chain fatty acids (SCFA; acetate, propionate, and butyrate). Six female pigs fitted with catheters in the portal vein and mesenteric artery...... >> arabinoxylan >> β-glucan, whereas in the WWG, WAF, and RAF, diets it was arabinoxylan >> cellulose > β-glucan. The diets were fed to the pigs during 3 wk in a crossover design. Within an experimental week, WFL was supplied on Days 1 through 3 and WWG, WAF, or RAF was supplied during Days 4 through 7. Fasting...

  9. Development of the dense plasma focus for short-pulse applications

    Science.gov (United States)

    Bennett, N.; Blasco, M.; Breeding, K.; Constantino, D.; DeYoung, A.; DiPuccio, V.; Friedman, J.; Gall, B.; Gardner, S.; Gatling, J.; Hagen, E. C.; Luttman, A.; Meehan, B. T.; Misch, M.; Molnar, S.; Morgan, G.; O'Brien, R.; Robbins, L.; Rundberg, R.; Sipe, N.; Welch, D. R.; Yuan, V.

    2017-01-01

    The dense plasma focus (DPF) has long been considered a compact source for pulsed neutrons and has traditionally been optimized for the total neutron yield. In this paper, we describe the efforts to optimize the DPF for short-pulse applications by introducing a reentrant cathode at the end of the coaxial plasma gun. The resulting neutron pulse widths are reduced by an average of 21 ±9 % from the traditional long-drift DPF design. Pulse widths and yields achieved from deuterium-tritium fusion at 2 MA are 61.8 ±30.7 ns FWHM and 1.84 ±0.49 ×1012 neutrons per shot. Simulations were conducted concurrently to elucidate the DPF operation and confirm the role of the reentrant cathode. A hybrid fluid-kinetic particle-in-cell modeling capability demonstrates correct sheath velocities, plasma instabilities, and fusion yield rates. Consistent with previous findings that the DPF is dominated by beam-target fusion from superthermal ions, we estimate that the thermonuclear contribution is at the 1% level.

  10. Measurement of the two-neutrino double-beta decay half-life of {sup 130}Te with the CUORE-0 experiment

    Energy Technology Data Exchange (ETDEWEB)

    Alduino, C.; Avignone, F.T.; Chott, N.; Creswick, R.J.; Rosenfeld, C.; Wilson, J. [University of South Carolina, Department of Physics and Astronomy, Columbia, SC (United States); Alfonso, K.; Hickerson, K.P.; Huang, H.Z.; Liu, X.; Trentalange, S.; Zhu, B.X. [University of California, Department of Physics and Astronomy, Los Angeles, CA (United States); Artusa, D.R. [University of South Carolina, Department of Physics and Astronomy, Columbia, SC (United States); INFN-Laboratori Nazionali del Gran Sasso, Assergi, L' Aquila (Italy); Azzolini, O.; Camacho, A.; Keppel, G.; Palmieri, V.; Pira, C. [INFN-Laboratori Nazionali di Legnaro, Legnaro, Padova (Italy); Banks, T.I.; Drobizhev, A.; Freedman, S.J.; Hennings-Yeomans, R.; O' Donnell, T.; Wagaarachchi, S.L. [University of California, Department of Physics, Berkeley, CA (United States); Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, CA (United States); Bari, G.; Deninno, M.M. [INFN-Sezione di Bologna, Bologna (Italy); Beeman, J.W. [Lawrence Berkeley National Laboratory, Materials Science Division, Berkeley, CA (United States); Bellini, F.; Cardani, L.; Casali, N.; Cosmelli, C.; Ferroni, F. [Sapienza Universita di Roma, Dipartimento di Fisica, Rome (Italy); INFN-Sezione di Roma, Rome (Italy); Bersani, A.; Caminata, A. [INFN-Sezione di Genova, Genova (Italy); Biassoni, M.; Carbone, L.; Cremonesi, O.; Ferri, E.; Giachero, A.; Pessina, G.; Previtali, E.; Rusconi, C. [INFN-Sezione di Milano Bicocca, Milan (Italy); Brofferio, C.; Capelli, S.; Carniti, P.; Cassina, L.; Chiesa, D.; Clemenza, M.; Faverzani, M.; Fiorini, E.; Gironi, L.; Gotti, C.; Maino, M.; Nucciotti, A.; Pavan, M.; Pozzi, S.; Sisti, M.; Terranova, F.; Zanotti, L. [Universita di Milano-Bicocca, Dipartimento di Fisica, Milan (Italy); INFN-Sezione di Milano Bicocca, Milan (Italy); Bucci, C.; Cappelli, L.; D' Addabbo, A.; Di Vacri, M.L.; Gorla, P.; Pattavina, L.; Pirro, S. [INFN-Laboratori Nazionali del Gran Sasso, Assergi, L' Aquila (Italy); Canonica, L. [INFN-Laboratori Nazionali del Gran Sasso, Assergi, L' Aquila (Italy); Massachusetts Institute of Technology, Cambridge, MA (United States); Cao, X.G.; Fang, D.Q.; Ma, Y.G.; Wang, H.W.; Zhang, G.Q. [Chinese Academy of Sciences, Shanghai Institute of Applied Physics, Shanghai (China); Copello, S.; Di Domizio, S.; Fernandes, G.; Marini, L.; Pallavicini, M. [INFN-Sezione di Genova, Genova (Italy); Universita di Genova, Dipartimento di Fisica, Genova (Italy); Cushman, J.S.; Davis, C.J.; Heeger, K.M.; Lim, K.E.; Maruyama, R.H. [Yale University, Department of Physics, New Haven, CT (United States); Dafinei, I.; Morganti, S.; Mosteiro, P.J.; Orio, F.; Pettinacci, V.; Tomei, C.; Vignati, M. [INFN-Sezione di Roma, Rome (Italy); Dell' Oro, S. [INFN-Laboratori Nazionali del Gran Sasso, Assergi, L' Aquila (Italy); INFN-Gran Sasso Science Institute, L' Aquila (Italy); Feintzeig, J.; Fujikawa, B.K.; Mei, Y.; Smith, A.R. [Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, CA (United States); Franceschi, M.A.; Ligi, C.; Napolitano, T.; Piperno, G. [INFN-Laboratori Nazionali di Frascati, Frascati, Rome (Italy); Giuliani, A.; Tenconi, M. [Universite Paris-Saclay, CSNSM, Univ. Paris-Sud, CNRS/IN2P3, Orsay (France); Gladstone, L.; Leder, A.; Winslow, L.A. [Massachusetts Institute of Technology, Cambridge, MA (United States); Gutierrez, T.D. [California Polytechnic State University, Physics Department, San Luis Obispo, CA (United States); Haller, E.E. [Lawrence Berkeley National Laboratory, Materials Science Division, Berkeley, CA (United States); University of California, Department of Materials Science and Engineering, Berkeley, CA (United States); Han, K. [Yale University, Department of Physics, New Haven, CT (United States); Shanghai Jiao Tong University, Department of Physics and Astronomy, Shanghai (China); Hansen, E. [University of California, Department of Physics and Astronomy, Los Angeles, CA (United States); Massachusetts Institute of Technology, Cambridge, MA (United States); Kadel, R. [Lawrence Berkeley National Laboratory, Physics Division, Berkeley, CA (United States); Kolomensky, Yu.G. [University of California, Department of Physics, Berkeley, CA (United States); Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, CA (United States); Lawrence Berkeley National Laboratory, Physics Division, Berkeley, CA (United States); Martinez, M. [Sapienza Universita di Roma, Dipartimento di Fisica, Rome (Italy); INFN-Sezione di Roma, Rome (Italy); Universidad de Zaragoza, Laboratorio de Fisica Nuclear y Astroparticulas, Zaragoza (Spain); Moggi, N. [INFN-Sezione di Bologna, Bologna (Italy); Alma Mater Studiorum-Universita di Bologna, Dipartimento di Scienze per la Qualita della Vita, Bologna (Italy); Nones, C. [Service de Physique des Particules, CEA/Saclay, Gif-sur-Yvette (France); Norman, E.B.; Wang, B.S. [Lawrence Livermore National Laboratory, Livermore, CA (United States); University of California, Department of Nuclear Engineering, Berkeley, CA (United States); Ouellet, J.L. [University of California, Department of Physics, Berkeley, CA (United States); Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, CA (United States); Massachusetts Institute of Technology, Cambridge, MA (United States); Pagliarone, C.E. [INFN-Laboratori Nazionali del Gran Sasso, Assergi, L' Aquila (Italy); Universita degli Studi di Cassino e del Lazio Meridionale, Dipartimento di Ingegneria Civile e Meccanica, Cassino (Italy); Sangiorgio, S.; Scielzo, N.D. [Lawrence Livermore National Laboratory, Livermore, CA (United States); Santone, D. [INFN-Laboratori Nazionali del Gran Sasso, Assergi, L' Aquila (Italy); Universita dell' Aquila, Dipartimento di Scienze Fisiche e Chimiche, L' Aquila (Italy); Singh, V. [University of California, Department of Physics, Berkeley, CA (US); Taffarello, L. [INFN-Sezione di Padova, Padova (IT); Wise, T. [Yale University, Department of Physics, New Haven, CT (US); University of Wisconsin, Department of Physics, Madison, WI (US); Woodcraft, A. [University of Edinburgh, SUPA, Institute for Astronomy, Edinburgh (GB); Zimmermann, S. [Lawrence Berkeley National Laboratory, Engineering Division, Berkeley, CA (US); Zucchelli, S. [INFN-Sezione di Bologna, Bologna (IT); Alma Mater Studiorum-Universita di Bologna, Dipartimento di Fisica e Astronomia, Bologna (IT)

    2017-01-15

    We report on the measurement of the two-neutrino double-beta decay half-life of {sup 130}Te with the CUORE-0 detector. From an exposure of 33.4 kg year of TeO{sub 2}, the half-life is determined to be T{sub 1/2}{sup 2ν} = [8.2 ± 0.2 (stat.) ± 0.6 (syst.)] x 10{sup 20} year. This result is obtained after a detailed reconstruction of the sources responsible for the CUORE-0 counting rate, with a specific study of those contributing to the {sup 130}Te neutrinoless double-beta decay region of interest. (orig.)

  11. The interaction between thermodynamic stability and buried free cysteines in regulating the functional half-life of fibroblast growth factor-1.

    Science.gov (United States)

    Lee, Jihun; Blaber, Michael

    2009-10-16

    Protein biopharmaceuticals are an important and growing area of human therapeutics; however, the intrinsic property of proteins to adopt alternative conformations (such as during protein unfolding and aggregation) presents numerous challenges, limiting their effective application as biopharmaceuticals. Using fibroblast growth factor-1 as model system, we describe a cooperative interaction between the intrinsic property of thermostability and the reactivity of buried free-cysteine residues that can substantially modulate protein functional half-life. A mutational strategy that combines elimination of buried free cysteines and secondary mutations that enhance thermostability to achieve a substantial gain in functional half-life is described. Furthermore, the implementation of this design strategy utilizing stabilizing mutations within the core region resulted in a mutant protein that is essentially indistinguishable from wild type as regard protein surface and solvent structure, thus minimizing the immunogenic potential of the mutations. This design strategy should be generally applicable to soluble globular proteins containing buried free-cysteine residues.

  12. Some problems of parametric neutron activation analysis based on the use of radioactive daughters of longer-lived mothers with low mother/daughter half-life ratios

    International Nuclear Information System (INIS)

    Cohen, I.M.

    2012-01-01

    The theoretical and practical aspects of the use of radioactive daughters originated from the decay of longer-lived radioactive mothers in parametric activation analysis, when the ratio: mother half-life to daughter half-life is less than 10, are discussed. The mother-daughter relationships: 47 Ca/ 47 Sc; 95 Zr/ 95 Nb; 140 Ba/ 140 La; 99 Mo/ 99m Tc and 115 Cd/ 115m In are selected as models for the study. The cases when the radionuclide of interest is formed through both direct and indirect routes are also analyzed. As illustrative example, the direct reaction and the reaction chain: 47 Ti(n,p) 47 Sc/ 46 Ca(n,γ) 47 Ca(β - ) 47 Sc are evaluated with respect to the determination of the elements involved and their reciprocal interferences. (author)

  13. Short (

    NARCIS (Netherlands)

    Telleman, Gerdien; den Hartog, Laurens

    2013-01-01

    Aim: This systematic review assessed the implant survival rate of short (<10 mm) dental implants installed in partially edentulous patients. A case report of a short implant in the posterior region have been added. Materials and methods: A search was conducted in the electronic databases of MEDLINE

  14. Pile-up corrections for high-precision superallowed β decay half-life measurements via γ-ray photopeak counting

    Science.gov (United States)

    Grinyer, G. F.; Svensson, C. E.; Andreoiu, C.; Andreyev, A. N.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Chakrawarthy, R. S.; Finlay, P.; Garrett, P. E.; Hackman, G.; Hyland, B.; Kulp, W. D.; Leach, K. G.; Leslie, J. R.; Morton, A. C.; Pearson, C. J.; Phillips, A. A.; Sarazin, F.; Schumaker, M. A.; Smith, M. B.; Valiente-Dobón, J. J.; Waddington, J. C.; Williams, S. J.; Wong, J.; Wood, J. L.; Zganjar, E. F.

    2007-09-01

    A general technique that corrects γ-ray gated β decay-curve data for detector pulse pile-up is presented. The method includes corrections for non-zero time-resolution and energy-threshold effects in addition to a special treatment of saturating events due to cosmic rays. This technique is verified through a Monte Carlo simulation and experimental data using radioactive beams of Na26 implanted at the center of the 8π γ-ray spectrometer at the ISAC facility at TRIUMF in Vancouver, Canada. The β-decay half-life of Na26 obtained from counting 1809-keV γ-ray photopeaks emitted by the daughter Mg26 was determined to be T=1.07167±0.00055 s following a 27σ correction for detector pulse pile-up. This result is in excellent agreement with the result of a previous measurement that employed direct β counting and demonstrates the feasibility of high-precision β-decay half-life measurements through the use of high-purity germanium γ-ray detectors. The technique presented here, while motivated by superallowed-Fermi β decay studies, is general and can be used for all half-life determinations (e.g. α-, β-, X-ray, fission) in which a γ-ray photopeak is used to select the decays of a particular isotope.

  15. Importance of neonatal FcR in regulating the serum half-life of therapeutic proteins containing the Fc domain of human IgG1: a comparative study of the affinity of monoclonal antibodies and Fc-fusion proteins to human neonatal FcR.

    Science.gov (United States)

    Suzuki, Takuo; Ishii-Watabe, Akiko; Tada, Minoru; Kobayashi, Tetsu; Kanayasu-Toyoda, Toshie; Kawanishi, Toru; Yamaguchi, Teruhide

    2010-02-15

    The neonatal FcR (FcRn) binds to the Fc domain of IgG at acidic pH in the endosome and protects IgG from degradation, thereby contributing to the long serum half-life of IgG. To date, more than 20 mAb products and 5 Fc-fusion protein products have received marketing authorization approval in the United States, the European Union, or Japan. Many of these therapeutic proteins have the Fc domain of human IgG1; however, the serum half-lives differ in each protein. To elucidate the role of FcRn in the pharmacokinetics of Fc domain-containing therapeutic proteins, we evaluated the affinity of the clinically used human, humanized, chimeric, or mouse mAbs and Fc-fusion proteins to recombinant human FcRn by surface plasmon resonance analysis. The affinities of these therapeutic proteins to FcRn were found to be closely correlated with the serum half-lives reported from clinical studies, suggesting the important role of FcRn in regulating their serum half-lives. The relatively short serum half-life of Fc-fusion proteins was thought to arise from the low affinity to FcRn. The existence of some mAbs having high affinity to FcRn and a short serum half-life, however, suggested the involvement of other critical factor(s) in determining the serum half-life of such Abs. We further investigated the reason for the relatively low affinity of Fc-fusion proteins to FcRn and suggested the possibility that the receptor domain of Fc-fusion protein influences the structural environment of the FcRn binding region but not of the FcgammaRI binding region of the Fc domain.

  16. Some Recent Applications of Short Half-Life Radioisotopes in Australia; Quelques Applications Recentes des Radioisotopes a Courte Periode En Australie; НОВЕЙШИЕ СПОСОБЫ ИСПОЛЬЗОВАНИЯ В АВСТРАЛИИ КОРОТКОЯИВУЩИХ РАДИОИЗОТОПОВ; Algunas Recientes Aplicaciones de los Radioisotopos de Periodo Corto en Australia

    Energy Technology Data Exchange (ETDEWEB)

    Watt, J. S. [Australian Atomic Energy Commission Research Establishment, Lucas Heights, NSW (Australia)

    1963-03-15

    This paper describes the use of short-lived radioisotopes in some of the field investigations recently carried out by the Isotope Division of the Australian Atomic Energy Commission. A radioisotope technique is being developed to trace air movements in clouds, principally for use in experiments related to cloud seeding. In a series of ten experiments, various quantities up to 2 c of copper-64 as finely particulate CuO have been released from an aircraft and traced by detecting, with a large crystal scintillometer, the {gamma}-rays emitted by the CuO distributed about the aircraft. A novel feature of the method is that, not only is the amount of radioactivity about the aircraft measured, but also the directional location of the source of radiation. This enables the navigation of the aircraft towards the centre of the radioactivity. A technique is being developed for large-scale ventilation and air pollution studies. Small amounts of copper-64, either as CuO powder or as copper adsorbed on particles, would be released and collected on filter paper using a high-speed air sampler. Experiments show that excellent discrimination against natural airborne radioactivity is obtained by using {gamma}-{gamma} coincidence techniques for detecting the copper-64 positron annihilation pair. The minimum detection level is about 1 x 10{sup -18} c Cu{sup 64}/cm{sup 3} of air. A method for detection of leaks in town gas distribution systems is described. About 500 {mu}c of bromine-82 labelled methyl bromide is used to test for leaks in the individual services between the gas main and meter, and a feature of the method is that most of the radioactive gas is withdrawn after the test and can be used again. Finally, experiments are briefly described in which gold-198 was used to trace silt, effluent and water movement. (author) [French] L'auteur decrit diverses recherches au moyen des radioisotopes a courte periode entreprises recemment par la Division des isotopes de la Commission

  17. Short-Lived Electronically-Excited Diatomic Molecules Cooled via Supersonic Expansion from a Plasma Microjet

    Science.gov (United States)

    Houlahan, Thomas J., Jr.; Su, Rui; Eden, Gary

    2014-06-01

    Using a pulsed plasma microjet to generate short-lived, electronically-excited diatomic molecules, and subsequently ejecting them into vacuum to cool via supersonic expansion, we are able to monitor the cooling of molecules having radiative lifetimes as low as 16 ns. Specifically, we report on the rotational cooling of He_2 molecules in the d^3Σ_u^+, e^3Π_g, and f^3Σ_u^+ states, which have lifetimes of 25 ns, 67 ns, and 16 ns, respectively. The plasma microjet is driven with a 2.6 kV, 140 ns high-voltage pulse (risetime of 20 ns) which, when combined with a high-speed optical imaging system, allows the nonequilibrium rotational distribution for these molecular states to be monitored as they cool from 1200 K to below 250 K with spatial and temporal resolutions of below 10 μm and 10 ns, respectively. The spatial and temporal resolution afforded by this system also allows the observation of excitation transfer between the f^3Σ_u^+ state and the lower lying d^3Σ_u^+ and e^3Π_g states. The extension of this method to other electronically excited diatomics with excitation energies >5 eV will also be discussed.

  18. Analytical basis for neutron-activation analysis measuring nuclides with a half-life of second order

    International Nuclear Information System (INIS)

    Yonezawa, Chushiro; Ichimura, Shigeju; Matsue, Hideaki; Kurosawa, Tatsuya

    1998-01-01

    An analytical basis for a neutron-activation analysis (NAA) for measuring nuclides of second-order half-lives produced by the (n, γ) reaction has been studied using a neutron-activation analysis facility (PN-3) of JRR-3M. The NAA facility, comprising a fast pneumatic irradiation system and a high count-rate gamma-ray spectrometer, is able to automatically conduct NAA with short-lived nuclides. Basic experimental conditions, such as a high count-rate gamma-ray measurement, the effects of irradiation-capsule material and the stability of the neutron flux, were examined. The analytical sensitivities and detection limits for 20 elements of which activated radionuclide having half-lives from 0.7 to 100 s were obtained. Scandium, In, Dy and Hf were elements having the highest analytical sensitivity, with detection limits down to 4.2 to 14 ng. Fluorine, which is difficult to determine by other methods, can be detected at above 530 ng. Analytical applications of NAA with short-lived nuclides have been carried out for F, Se, Sc, Hf, In and Dy in various materials, including reference materials. The accuracy, precision and detection limits of NAA with short-lived nuclides have been evaluated. (author)

  19. Short wavelength laser-plasma interaction experiments in a spherical geometry

    International Nuclear Information System (INIS)

    Keck, R.L.

    1984-01-01

    Short wavelength (250 to 500 nm) lasers should provide reduced fast electron preheat and increased laser-pellet coupling efficiency when used as laser fusion drivers. As part of an ongoing effort to study short wavelength laser plasm interaction, six beams of the 24 beam OMEGA Nd-glass laser system have been converted to operation at the third harmonic. This system is capable of providing in excess of 250 Joules of 351 nm light on spherical targets at intensities up to 2 x 10/sup 15/ W/cm/sup 2/. To date, experiments have been performed to study the uniformity of irradiation, laser absorption, fast electron production and preheat, energy transport within the target and underdense plasma instabilities. Both x-ray continuum measurements and Kα line measurements indicate that the absorption is dominated by inverse bremsstrahlung. Electron energy transport has been studied using x-ray burn-through and charge collector measurements. The results show that with 351 nm irradiation ablation pressures of order 100 Mbars are generated at intensities of 10/sup 15/ W/cm/sup 2/

  20. Simulation of primary processes for laser-induced plasma by short laser pulses in KDP crystal

    International Nuclear Information System (INIS)

    Gayet, R.; Jequier, S.; Bachau, H.; Rodriguez, V.; Duchateau, G.; Dyan, A.; Mathis, H.

    2006-01-01

    Complete test of publication follows. A theoretical approach designed for the description of local micro-plasma formation induced by short laser pulses in KH 2 PO 4 (KDP) crystal is addressed. Indeed, when such a crystal is illuminated by short pulses, the early stage of photo-production, enhanced by local defects, leads to a subsequent strong electronic absorption revealing a transient metallic-like behavior. The lattice then is rapidly heated up by electron-phonon coupling at temperature as high as 10000 K. This results in the local formation of a micro-plasma whose initial electronic energy distribution, which can be used in Particle-In-Cell codes, may be predicted by the present approach. The latter includes both, electron promotion from the valence band to the conduction band, and the subsequent interaction with phonons and photons. The electron promotion is described by a theoretical method based on Coulomb-Volkov (CV) wave functions whereas the electron diffusion in the conduction band is described by the standard Boltzmann's formalism. Although results about diffusion are shown, the present work focuses on the photo-production step. Hence, an extension of a previous theory, which has been developed essentially to describe ionization of atoms or molecules by intense femtosecond laser pulses, in under way. The first theory gives reliable predictions whenever both, (i) the photon energy is greater than the ionization potential, and (ii) perturbation conditions prevail. The restriction (i) prevents from intermediate state contribution to the ionization mechanism. The CV approach has been improved by introducing these states in the initial wave function, thus leading to an excellent agreement with predictions based on a full numerical solution to the time-dependent Schroedinger equation. Further, keeping the restriction (i), one can discard the condition (ii) by introducing a time-dependent initial state population in a CV approach. Since defects induce

  1. Short- and long-term plasma phenomena in a HiPIMS discharge

    International Nuclear Information System (INIS)

    Poolcharuansin, P; Bradley, J W

    2010-01-01

    Using a time-resolved Langmuir probe the temporal evolution of the bulk plasma parameters in a high-power impulse magnetron sputtering (HiPIMS) discharge was investigated for a number of different discharge conditions. The magnetron was operated in argon between 0.5 and 1.6 Pa with a titanium target and with peak target power densities up to 1000 W cm -2 . The pulse width and repetition rate were held constant at 100 μs and 100 Hz, respectively. Using an OML analysis as well as a Druyvesteyn formulation, the electron densities, effective temperatures and energy distribution functions were obtained throughout the pulse period (0-9 ms), including a detailed study of the first 10 μs, which was achieved with a temporal resolution better than 0.5 μs. In the initial phase of the voltage pulse (t ∼ 1-4 μs), three distinct groups of electrons (indistinguishable from Maxwellian electrons) were observed, namely 'super-thermal', 'hot' and 'cold' populations with effective temperatures of 70-100 eV, 5-7 eV and 0.8-1 eV, respectively. After 4 μs these groups become energetically indistinguishable from each other to form a single distribution with an electron temperature that decays from about 5 to 3 eV during the rest of the pulse on-time. The presence of the 'super-thermal' electron group pushes the probe floating potential to a very negative value (significantly deeper than -95 V) during the initial period of the pulse. In the off-time, the electron density decays with two-fold characteristic times, revealing initially short-term (30-40 μs) and ultimately long-term (3-4 ms) decay rates. These long decay times lead to a relative high density remnant plasma (2 x 10 9 cm -3 ) at the end of the off-time, which serves to seed the next voltage pulse. The electron temperature and plasma potential also exhibit two-fold decay in the off-time, but with typically somewhat faster decays, particularly for the long-term decay (100-500 μs) up to the end of the off-time. The time

  2. Hair-to-blood ratio and biological half-life of mercury: experimental study of methylmercury exposure through fish consumption in humans.

    Science.gov (United States)

    Yaginuma-Sakurai, Kozue; Murata, Katsuyuki; Iwai-Shimada, Miyuki; Nakai, Kunihiko; Kurokawa, Naoyuki; Tatsuta, Nozomi; Satoh, Hiroshi

    2012-02-01

    The hair-to-blood ratio and biological half-life of methylmercury in a one-compartment model seem to differ between past and recent studies. To reevaluate them, 27 healthy volunteers were exposed to methylmercury at the provisional tolerable weekly intake (3.4 µg/kg body weight/week) for adults through fish consumption for 14 weeks, followed by a 15-week washout period after the cessation of exposure. Blood was collected every 1 or 2 weeks, and hair was cut every 4 weeks. Total mercury (T-Hg) concentrations were analyzed in blood and hair. The T-Hg levels of blood and hair changed with time (p < 0.001). The mean concentrations increased from 6.7 ng/g at week 0 to 26.9 ng/g at week 14 in blood, and from 2.3 to 8.8 µg/g in hair. The mean hair-to-blood ratio after the adjustment for the time lag from blood to hair was 344 ± 54 (S.D.) for the entire period. The half-lives of T-Hg were calculated from raw data to be 94 ± 23 days for blood and 102 ± 31 days for hair, but the half-lives recalculated after subtracting the background levels from the raw data were 57 ± 18 and 64 ± 22 days, respectively. In conclusion, the hair-to-blood ratio of methylmercury, based on past studies, appears to be underestimated in light of recent studies. The crude half-life may be preferred rather than the recalculated one because of the practicability and uncertainties of the background level, though the latter half-life may approximate the conventional one.

  3. Proposal of a new model for dose calculation due to the inhalation of Ru-222, Ru-220 and their sons with brief half-life

    International Nuclear Information System (INIS)

    Mauricio, C.L.P.

    1982-06-01

    The consequences of the radiation interactions upon the human body are studied. In order to simulate by computer the radiation interaction of the atoms of radon and thoron atoms and their Sons with a brief half life inhaled with the cells, the compartimental dosimetric model is used. The metabolic pathway of those radionuclides is described by continuous medium dynamic differential equation. The energy transfer processes are seen in details. The individual retention function is determined by bio-analysis. The results of internal dosimetry are consistents with the new international recommendations from ICRP-32. (L.F.S.) [pt

  4. Precision measurement of the half-life of {sup 90m}Nb and {sup 99m}Tc

    Energy Technology Data Exchange (ETDEWEB)

    Kikunaga, H.; Fujisawa, H.; Ooe, K. [Osaka Univ., Toyonaka (Japan). Graduate School of Science] [and others

    2011-07-01

    We have produced {sup 90m}Nb and {sup 99m}Tc in the reactions of {sup nat}Zr(p, xn){sup 90m}Nb and {sup 100}Mo({gamma}, n){sup 99}Mo, followed by disintegration to {sup 99m}Tc, respectively, and measured the halflives of these nuclides by using a reference source method. In order to determine the short half-lives of {sup 90m}Nb precisely, an on-line gas-jet system has been employed. As a result, the half-lives of these nuclides were determined with good precision on the order of magnitude of 0.1%. (orig.)

  5. Increased kidney size, glomerular filtration rate and renal plasma flow in short-term insulin-dependent diabetics

    DEFF Research Database (Denmark)

    Christiansen, JS; Gammelgaard, J; Frandsen, M

    1981-01-01

    Glomerular filtration rate (GFR), renal plasma flow (RPF) and kidney volume were measured in thirteen male subjects (mean age 30 years) with short-term insulin-dependent diabetes (mean duration of disease 2.4 years) and fourteen normal male subjects (mean age 29 years). GFR and RPF were measured...

  6. Stationary spectra of short-wave convective and magnetostatic fluctuations in a finite-pressure plasma and anomalous heat conductivity

    International Nuclear Information System (INIS)

    Vakulenko, M.O.

    1992-01-01

    Within the general renormalized statistical approach, the low-frequency short-wave stationary spectra of potential and magnetic perturbations in a finite-pressure plasma, are obtained. Anomalous heat conductivity considerably enhances due to non-linear interaction between magnetic excitations. 11 refs. (author)

  7. Laser injection of ultra-short electron bursts for the diagnosis of Hall thruster plasma

    International Nuclear Information System (INIS)

    Albarede, L; Gibert, T; Lazurenko, A; Bouchoule, A

    2006-01-01

    The present developments of Hall thrusters for satellite control and space mission technologies represent a new step towards their routine use in place of conventional thermal thrusters. In spite of their long R and D history, the complex physics of the E x B discharge at work in these structures has prevented, up to now, the availability of predictive simulations. The electron transport in the accelerating layers of these thrusters is one of the remaining challenges in this direction. From the experimental point of view, any diagnostics of electron transport and electric field in this critical layer would be welcome for comparison with code predictions. Appropriate diagnostics are difficult, due to the very aggressive local plasma conditions. This paper presents the first step in the development of a new tool for characterization of the plasma electric field in the very near exhaust thruster plume and comparison with simulation code predictions. The main idea is to use very short bursts of electrons, probing local electron dynamics in this critical plume area. Such bursts can be obtained through photoelectric emission induced by a UV pulsed laser beam on a convenient target. A specific study, devoted to the characterization of the electron burst emission, is presented in the first section of the paper; the implementation and testing of the injection of electrons in the critical layer of Hall thruster plasma is described in the second section. The design and testing of a fast and sensitive system for characterizing the transport of injected bursts will be the next step of this program. It requires a preliminary evaluation of electron trajectories which was achieved by using simulation code. Simulation data are presented in the last section of the paper, with the full diagnostic design to be tested in the near future, when runs will be available in the renewed PIVOINE facility. The same electron burst injection could also be a valuable input in the present

  8. Implications of electronic short circuiting in plasma sprayed solid oxide fuel cells on electrode performance evaluation by electrochemical impedance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    White, B.D. [Department of Mechanical Engineering, The University of British Columbia, 2054-6250 Applied Sciences Lane, Vancouver, British Columbia (Canada); Kesler, O. [Department of Mechanical and Industrial Engineering, University of Toronto, 5 King' s College Road, Toronto, Ontario (Canada)

    2008-02-15

    Electronic short circuiting of the electrolyte in a solid oxide fuel cell (SOFC) arising from flaws in the plasma spray fabrication process has been found to have a significant effect on the perceived performance of the electrodes, as evaluated by electrochemical impedance spectroscopy (EIS). The presence of a short circuit has been found to lead to the underestimation of the electrode polarization resistance (R{sub p}) and hence an overestimation of electrode performance. The effect is particularly noticeable when electrolyte resistance is relatively high, for example during low to intermediate temperature operation, leading to an obvious deviation from the expected Arrhenius-type temperature dependence of R{sub p}. A method is developed for determining the real electrode performance from measurements of various cell properties, and strategies for eliminating the occurrence of short circuiting in plasma sprayed cells are identified. (author)

  9. Implications of electronic short circuiting in plasma sprayed solid oxide fuel cells on electrode performance evaluation by electrochemical impedance spectroscopy

    Science.gov (United States)

    White, B. D.; Kesler, O.

    Electronic short circuiting of the electrolyte in a solid oxide fuel cell (SOFC) arising from flaws in the plasma spray fabrication process has been found to have a significant effect on the perceived performance of the electrodes, as evaluated by electrochemical impedance spectroscopy (EIS). The presence of a short circuit has been found to lead to the underestimation of the electrode polarization resistance (R p) and hence an overestimation of electrode performance. The effect is particularly noticeable when electrolyte resistance is relatively high, for example during low to intermediate temperature operation, leading to an obvious deviation from the expected Arrhenius-type temperature dependence of R p. A method is developed for determining the real electrode performance from measurements of various cell properties, and strategies for eliminating the occurrence of short circuiting in plasma sprayed cells are identified.

  10. New AMS method to measure the atom ratio {sup 146}Sm/{sup 147}Sm for a half-life determination of {sup 146}Sm

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, N. [Tandem Accelerator Complex, Research Facility Center for Science and Technology, University of Tsukuba (Japan); Paul, M., E-mail: paul@vms.huji.ac.il [Racah Institute of Physics, Hebrew University, Jerusalem 91904 (Israel); Alcorta, M. [Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Bowers, M.; Collon, P. [Department of Physics, University of Notre Dame, Notre Dame, IN 46556-5670 (United States); Deibel, C.M. [Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Joint Institute for Nuclear Astrophysics, Michigan State University, East Lansing, MI 46624 (United States); DiGiovine, B. [Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Goriely, S. [Universite Libre de Bruxelles, CP-226, Brussels 1050 (Belgium); Greene, J.P.; Henderson, D.J.; Jiang, C.L. [Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Kashiv, Y. [Department of Physics, University of Notre Dame, Notre Dame, IN 46556-5670 (United States); Kay, B.P.; Lee, H.Y.; Marley, S.T. [Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Nakanishi, T. [Faculty of Chemistry, Institute of Science and Engineering, Kanazawa University (Japan); Pardo, R.C.; Patel, N.; Rehm, K.E. [Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Robertson, D. [Department of Physics, University of Notre Dame, Notre Dame, IN 46556-5670 (United States); and others

    2013-01-15

    The extinct p-process nuclide {sup 146}Sm (t{sub 1/2} = 103 {+-} 5 Myr) is known to have been present in the Early-Solar System and has been proposed as an astrophysical chronometer. {sup 146}Sm is also intensely used to date meteorite and planetary differentiation processes, enhancing the importance of an accurate knowledge of the {sup 146}Sm half-life. We are engaged in a new determination of the {sup 146}Sm half-life in which the {sup 146}Sm/{sup 147}Sm atom ratio is determined by accelerator mass spectrometry at the ATLAS facility of Argonne National Laboratory. In order to reduce systematic errors in the AMS determination of the {sup 146}Sm/{sup 147}Sm ratios (in the range of 10{sup -7}-10{sup -9}), {sup 146}Sm and {sup 147}Sm ions were alternately counted in the same detector in the focal plane of a gas-filled magnet, respectively in continuous-wave and attenuated mode. Quantitative attenuation is obtained with the 12 MHz pulsed and ns-bunched ATLAS beam by chopping beam pulses with an RF sweeper in a ratio (digitally determined) down to 1:10{sup 6}. The experiments and preliminary results are discussed.

  11. Prediction of drug terminal half-life and terminal volume of distribution after intravenous dosing based on drug clearance, steady-state volume of distribution, and physiological parameters of the body.

    Science.gov (United States)

    Berezhkovskiy, Leonid M

    2013-02-01

    The steady state, V(ss), terminal volume of distribution, V(β), and the terminal half-life, t(1/2), are commonly obtained from the drug plasma concentration-time profile, C(p)(t), following intravenous dosing. Unlike V(ss) that can be calculated based on the physicochemical properties of drugs considering the equilibrium partitioning between plasma and organ tissues, t(1/2) and V(β) cannot be calculated that way because they depend on the rates of drug transfer between blood and tissues. Considering the physiological pharmacokinetic model pertinent to the terminal phase of drug elimination, a novel equation that calculates t(1/2) (and consequently V(β)) was derived. It turns out that V(ss), the total body clearance, Cl, equilibrium blood-plasma concentration ratio, r; and the physiological parameters of the body such as cardiac output, and blood and tissue volumes are sufficient for determination of terminal kinetics. Calculation of t(1/2) by the obtained equation appears to be in good agreement with the experimentally observed vales of this parameter in pharmacokinetic studies in rat, monkey, dog, and human. The equation for the determination of the pre-exponent of the terminal phase of C(p)(t) is also found. The obtained equation allows to predict t(1/2) in human assuming that V(ss) and Cl were either obtained by allometric scaling or, respectively, calculated in silico or based on in vitro drug stability measurements. For compounds that have high clearance, the derived equation may be applied to calculate r just using the routine data on Cl, V(ss), and t(1/2), rather than doing the in vitro assay to measure this parameter. Copyright © 2012 Wiley Periodicals, Inc.

  12. Interaction of ultra-short ultra-intense laser pulses with under-dense plasmas; Interaction d'impulsions laser ultra-courtes et ultra-intenses avec des plasmas sous denses

    Energy Technology Data Exchange (ETDEWEB)

    Solodov, A

    2000-12-15

    Different aspects of interaction of ultra-short ultra-intense laser pulses with underdense plasmas are studied analytically and numerically. These studies can be interesting for laser-driven electron acceleration in plasma, X-ray lasers, high-order harmonic generation, initial confinement fusion with fast ignition. For numerical simulations a fully-relativistic particle code WAKE was used, developed earlier at Ecole Polytechnique. It was modified during the work on the thesis in the part of simulation of ion motion, test electron motion, diagnostics for the field and plasma. The studies in the thesis cover the problems of photon acceleration in the plasma wake of a short intense laser pulse, phase velocity of the plasma wave in the Self-Modulated Laser Wake-Field Accelerator (SM LWFA), relativistic channeling of laser pulses with duration of the order of a plasma period, ion dynamics in the wake of a short intense laser pulse, plasma wave breaking. Simulation of three experiments on the laser pulse propagation in plasma and electron acceleration were performed. Among the main results of the thesis, it was found that reduction of the plasma wave phase velocity in the SM LWFA is crucial for electron acceleration, only if a plasma channel is used for the laser pulse guiding. Self-similar structures describing relativistic guiding of short laser pulses in plasmas were found and relativistic channeling of initially Gaussian laser pulses of a few plasma periods in duration was demonstrated. It was shown that ponderomotive force of a plasma wake excited by a short laser pulse forms a channel in plasma and plasma wave breaking in the channel was analyzed in detail. Effectiveness of electron acceleration by the laser field and plasma wave was compared and frequency shift of probe laser pulses by the plasma waves was found in conditions relevant to the current experiments. (author)

  13. Inactivation of Escherichia coli on blueberries using cold plasma with chemical augmentation inside a partial vacuum

    Science.gov (United States)

    Justification: The mechanism by which cold plasma inactivates pathogens is through the production of free reactive chemical species. Unfortunately, the most reactive chemical species have the shortest half-life. In a vacuum their half-life is believed to be prolonged. Additionally, these reactive sp...

  14. Goiania radiation accident: 30 years - a half-life for a whole life..; Acidente radiológico em Goiânia: 30 - anos - uma meia-vida para uma vida inteira...

    Energy Technology Data Exchange (ETDEWEB)

    Reis, R.G.; Lucena, E.A.; Arantes, R.R.; Silva, A.A.; Reis, A.A., E-mail: rocio@ird.gov.br [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Serviço de Ensino

    2017-07-01

    The radiological accident in Goiânia, Brazil, considered the largest urban radiological accident in the world, generated several publications in the technical area that are widely disseminated in the scientific literature, given the importance of the lessons learned. However, in a simple conversation with people who worked on that accident, it is noted that many reports have not been recorded. In this year in which 30 years of the event is completed, it will be of great value to record personal testimonies that are not in technical or scientific books. And what can we tell after a half-life that lasted for a lifetime? The lived stories, the situations, the improvisations, the way to solve, the overcoming, the human side, the emotions, happy or sad, short or long, funny or not. The objective of this work is to preserve, maintain and divulge reports and situations experienced by people who worked on the radiological accident with Cs-137 in Goiânia. Audio or video recordings about experiences lived in Goiânia by people who worked in that emergency situation were carried out. The reports are free and the form of registration is always at the discretion of the narrator. Storing records allows to preserve, maintain, and disclose the accident to other generations.

  15. Purification of a 166mHo solution by successive high-performance liquid chromatography and gravitational chromatography for half-life determination

    International Nuclear Information System (INIS)

    Florence Gueguen; Helene Isnard; Carole Bresson; Celine Caussignac; Guillaume Stadelmann; Anthony Nonell; Sebastien Mialle; Karsten Kossert; Frederic Chartier

    2014-01-01

    A methodology to purify a 166m Ho solution has been developed by a combination of activity and mass concentration measurements in order to further determine the 166m Ho half-life. The isobaric interference at m/q ≃ 166 requires Ho purification from non-natural Er with a high purification degree due to the large amount of Ho as opposed to Er. The Ho/Er separation was achieved using high-performance liquid chromatography on a semi-preparative column followed by purification on gravitational chromatography. The efficiency of the separation was evaluated after precise determination of the Er isotopic composition. The purification methodology enabled to separate Ho from Er. (author)

  16. The analysis of predictability of α-decay half-life formulae and the α partial half-lives of some exotic nuclei

    International Nuclear Information System (INIS)

    Dasgupta-Schubert, N.; Reyes, M.A.; Tamez, V.A.

    2009-01-01

    The predictabilities of the three α-decay half-life formulae, the Royer GLDM, the Viola-Seaborg and the Sobiczewski-Parkhomenko formulae, have been evaluated by developing a method based on the ansatz of standard experimental benchmarking. The coefficients of each formula were re-derived using the reliable data of the α -standards nuclei. The modified formulae that resulted were used to evaluate the accuracies of the formulae towards the prediction of half-lives of a set of nuclides with well-studied α spectroscopic data as well as a set of exotic α emitters. Further, a simple linear optimisation of the modified formulae allowed adjustments for the insufficient statistics of the primary data set without changing the modified formulae. While the three modified formulae showed equivalent results for all the medium heavy nuclei except the odd-odd, the modified GLDM showed relatively the best figures of merit for the odd-odd and superheavy nuclides. (orig.)

  17. Half-life Measurements of {sup 6}He, {sup 16}N, {sup 19}O, {sup 20}F, {sup 28}Al, {sup 77m}Se and {sup 1}

    Energy Technology Data Exchange (ETDEWEB)

    Konijn, J; Malmskog, S

    1962-06-15

    The half-life of different isotopes, activated by neutrons in the reactor R2-0 by means of a pneumatic rabbit, have been measured with a pulse height analyzer working in its multiscale mode of operation. A Nal(Tl)-scintillation spectrometer was used as detector. Least squares analysis calculated by the Mercury computer were performed for each measurement. The following weighted mean values of the half-lives are obtained {sup 6}He: 0.862 {+-} 0.017 sec.; {sup 16}N: 7.31 {+-} 0.04 sec.; {sup 19}O: 29.1 {+-} 0.3 sec.; {sup 20}F: 11.56 {+-} 0.05 sec.; {sup 28}Al: 2.31 {+-} 0.01 min.; {sup 77m}Se: 18.83 - 0.04 sec.; and {sup 110}Ag: 24.42 {+-} 0.14 sec.

  18. The effective and environmental half-life of {sup 137}Cs at Coral Islands at the former US nuclear test site

    Energy Technology Data Exchange (ETDEWEB)

    Robison, William L. E-mail: robison1@llnl.gov; Conrado, Cynthia L.; Bogen, Kenneth T.; Stoker, A. Carol

    2003-07-01

    The United States (US) conducted nuclear weapons testing from 1946 to 1958 at Bikini and Enewetak Atolls in the northern Marshall Islands. Based on previous detailed dose assessments for Bikini, Enewetak, Rongelap, and Utirik Atolls over a period of 28 years, cesium-137 ({sup 137}Cs) at Bikini Atoll contributes about 85-89% of the total estimated dose through the terrestrial food chain as a result of uptake of {sup 137}Cs by food crops. The estimated integral 30, 50, and 70-year doses were based on the radiological decay of {sup 137}Cs (30-year half-life) and other radionuclides. However, there is a continuing inventory of {sup 137}Cs and {sup 90}Sr in the fresh water portion of the groundwater at all contaminated atolls even though the turnover rate of the fresh groundwater is about 5 years. This is evidence that a portion of the soluble fraction of {sup 137}Cs and {sup 90}Sr inventory in the soil is lost by transport to groundwater when rainfall is heavy enough to cause recharge of the lens, resulting in loss of {sup 137}Cs from the soil column and root zone of the plants. This loss is in addition to that caused by radioactive decay. The effective rate of loss was determined by two methods: (1) indirectly, from time-dependent studies of the {sup 137}Cs concentration in leaves of Pisonia grandis, Guettarda specosia, Tournefortia argentea (also called Messerschmidia), Scaevola taccada, and fruit from Pandanus and coconut trees (Cocos nucifera L.), and (2) more directly, by evaluating the {sup 137}Cs/{sup 90}Sr ratios at Bikini Atoll. The mean (and its lower and upper 95% confidence limits) for effective half-life and for environmental-loss half-life (ELH) based on all the trees studied on Rongelap, Bikini, and Enewetak Atolls are 8.5 years (8.0 years, 9.8 years), and 12 years (11 years, 15 years), respectively. The ELH based on the {sup 137}Cs/{sup 90}Sr ratios in soil in 1987 relative to the{sup 137}Cs/{sup 90}Sr ratios at the time of deposition in 1954 is less

  19. Impacts of Ambient and Ablation Plasmas on Short- and Ultrashort-Pulse Laser Processing of Surfaces

    Directory of Open Access Journals (Sweden)

    Nadezhda M. Bulgakova

    2014-12-01

    Full Text Available In spite of the fact that more than five decades have passed since the invention of laser, some topics of laser-matter interaction still remain incompletely studied. One of such topics is plasma impact on the overall phenomenon of the interaction and its particular features, including influence of the laser-excited plasma re-radiation, back flux of energetic plasma species, and massive material redeposition, on the surface quality and processing efficiency. In this paper, we analyze different plasma aspects, which go beyond a simple consideration of the well-known effect of plasma shielding of laser radiation. The following effects are considered: ambient gas ionization above the target on material processing with formation of a “plasma pipe”; back heating of the target by both laser-driven ambient and ablation plasmas through conductive and radiative heat transfer; plasma chemical effects on surface processing including microstructure growth on liquid metals; complicated dynamics of the ablation plasma flow interacting with an ambient gas that can result in substantial redeposition of material around the ablation spot. Together with a review summarizing our main to-date achievements and outlining research directions, we present new results underlining importance of laser plasma dynamics and photoionization of the gas environment upon laser processing of materials.

  20. A drift-ordered short mean-free path description of a partially ionized magnetized plasma

    International Nuclear Information System (INIS)

    Simakov, Andrei N

    2009-01-01

    Neutral particles that are present at the edge of plasma magnetic confinement devices can play an important role in energy and momentum transport, and their effects should be accounted for. This work uses the drift ordering to derive a closed fluid description for a collisional, magnetized, partially ionized plasma. Charge-exchange, ionization and recombination processes are taken into account. It is assumed that electron distribution function is unaffected by atomic processes, so that electron-ion momentum and energy exchange are described by the usual expressions for a fully ionized plasma, and that neutral-neutral collisions are unimportant. The collisional fluid equations derived herein generalize the drift-ordered description of a fully ionized collisional plasma (Catto P J et al 2004 Phys. Plasmas 11 90), agree with the MHD-ordered description of a partially ionized plasma (Helander P et al 1994 Phys. Plasmas 1 3174) in the large-flow limit and can be used to describe both turbulent and collisional behavior of a partially ionized plasma.

  1. Enhanced self-magnetic field by atomic polarization in partially stripped plasma produced by a short and intense laser pulse

    International Nuclear Information System (INIS)

    Hu Qianglin; Liu Shibing; Jiang, Y.J.; Zhang Jie

    2005-01-01

    The enhancement and redistribution of a self-generated quasistatic magnetic field, due to the presence of the polarization field induced by partially ionized atoms, are analytically revealed when a linearly polarized intense and short pulse laser propagates in a partially stripped plasma with higher density. In particular, the shorter wavelength of the laser pulse can evidently intensify the amplitude of the magnetic field. These enhancement and redistribution of the magnetic field are considered physically as a result of the competition of the electrostatic field (electron-ion separation) associated with the plasma wave, the atomic polarization field, and the pondoromotive potential associated with the laser field. This competition leads to the generation of a positive, large amplitude magnetic field in the zone of the pulse center, which forms a significant difference in partially and fully stripped plasmas. The numerical result shows further that the magnetic field is resonantly modulated by the plasma wave when the pulse length is the integer times the plasma wavelength. This apparently implies that the further enhancement and restructure of the large amplitude self-magnetic field can evidently impede the acceleration and stable transfer of the hot-electron beam

  2. Determination of half life of the pesticides chlorpyrifos (14C) in an agricultural soil of the VI region by means of the using isotopic techniques

    International Nuclear Information System (INIS)

    Camarda Rojas, Gabriela Paz

    2005-01-01

    Chlorpyrifos is an organophosphorus insecticide widely used in Chilean agriculture in the control of plagues of insects in soil and several crops. From an environmental point of view, to know the behavior and fate of Chlorpyrifos under different moisture regimes in soil is important because it contributes to optimize its use, assuring that collateral effects do not take place inside or outside the application area and in addition it specifies the optimal conditions of application to obtain better results in the treatment with the land insecticide. In this work it was studied the half life of Chlorpyrifos ( 14 C) in an agricultural soil of VI Region, by means of the use of Isotopic techniques, under two moisture regimes of 50 and 75% of the Field Capacity. The ground samples were fortified with doses of 10 mg/Kg and incubated to 20 o C and in absence of light. The dissipation of Chlorpyrifos in soil was determined during 110 days of test, through the quantification of remaining 14 CO 2 by liquid scintillation counting. Results show temporary differences in the half life for different moisture regimes, with T 1/2 of 21 and 28 days for the soil to 75 and 50% of the Field Capacity, respectively. It was studied the factors related to soil and plaguicide that could affect speed of degradation, either accelerating or inhibiting the process of dissipation of Chlorpyrifos, under the described moisture regimes. The results indicated that the fast degradation of the insecticide organophosphorus in the soil to 75% of the CC is product of biotic and abiotic processes. Between the abiotic processes the neutral hydrolysis constituted the principal route of dissipation, mainly due to the moisture content and pH presented in soil (pH 7,2). Nevertheless, factors as the high content of organic matter of the soil, low water solubility, high coefficient of adsorption and bond p=S of the Chlorpyrifos, they suggest the sorption process would inhibit hydrolysis, slowing down the

  3. About the short-scale perturbations of plasma in gravitational field

    International Nuclear Information System (INIS)

    Gedalin, M.E.; Machabeli, G.Z.

    1985-01-01

    The problem of plasma wave generation and propagation in the presence of strong gravitational fields is studied in the framework of general relativity theory. The coupled relativistic hydrodynamic and Maxwellian equations are solved in circumstances of the surface of the neutron star. The wave solution of the system of equation is analyzed, some limit cases are discussed in detail. The instability criteria of relativistic plasma are also found. (D.Gy.)

  4. Metabolically stable bradykinin B2 receptor agonists enhance transvascular drug delivery into malignant brain tumors by increasing drug half-life

    Directory of Open Access Journals (Sweden)

    Glen Daniel

    2009-05-01

    -lysine-bradykinin and labradimil increased the blood half-life of Gd-DTPA sufficiently enough to increase significantly the tumor tissue Gd-DTPA area under the time-concentration curve. Conclusion Metabolically stable bradykinin B2 receptor agonists, methionine-lysine-bradykinin and labradimil, enhance the transvascular delivery of small chemotherapy drugs across the BBTB of malignant gliomas by increasing the blood half-life of the co-infused drug. The selectivity of the increase in drug delivery into the malignant glioma tissue, but not into normal brain tissue or skeletal muscle tissue, is due to the inherent porous nature of the BBTB of malignant glioma microvasculature.

  5. Short-term folic acid supplementation induces variable and paradoxical changes in plasma homocyst(e)ine concentrations.

    Science.gov (United States)

    Malinow, M R; Duell, P B; Williams, M A; Kruger, W D; Evans, A A; Anderson, P H; Block, P C; Hess, D L; Upson, B M; Graf, E E; Irvin-Jones, A; Wang, L

    2001-01-01

    Folic acid is presently the mainstay of treatment for most subjects with elevated plasma homocyst(e)ine concentrations [Plasma or serum homocyst(e)ine, or total homocysteine, refers to the sum of the sulfhydryl amino acid homocysteine and the homocysteinyl moieties of the disulfides homocystine and homocystein-cysteine, whether free or bound to plasma proteins.] Changes in homocyst(e)ine in response to folic acid supplementation are characterized by considerable interindividual variation. The purpose of this study was to identify factors that contribute to heterogeneity in short-term responses to folic acid supplementation. The effects of folic acid supplementation (1 or 2 mg per day) for 3 wk on plasma homocyst(e)ine concentrations were assessed in 304 men and women. Overall, folic acid supplementation increased mean plasma folate 31.5 +/- 98.0 nmol/L and decreased mean plasma homocyst(e)ine concentrations 1.2 +/- 2.4 micromol/L. There was evidence of substantial interindividual variation in the homocyst(e)ine response from -18.5 to +7.1 micromol/L, including an increase in homocyst(e)ine in 20% of subjects (mean increase 1.5 +/- 1.4 micromol/L). Basal homocyst(e)ine, age, male gender, cigarette smoking, use of multivitamins, methylene tetrahydrofolate reductase, and cystathionine beta-synthase polymorphisms accounted for 47.6% of the interindividual variability in the change in homocyst(e)ine after folic acid supplementation, but about 50% of variability in response to folic acid was not explained by the variables we studied.

  6. Experimental study of laser-plasma interaction physics with short laser wavelength

    International Nuclear Information System (INIS)

    Labaune, C.; Amiranoff, F.; Fabre, E.; Matthieussent, G.; Rousseaux, C.; Baton, S.

    1989-01-01

    Many non-linear processes can affect laser-plasma coupling in fusion experiments. The interaction processes of interest involve three or more waves, including the incident electromagnetic wave and various selections of electromagnetic, electrostatic and accoustic waves. Whenever plasma waves are involved (stimulated Raman scattering, two-plasmon decay instability, parametric decay instability and others), energetic electrons are created through the various damping processes of these waves: these energetic electrons in turn deleteriously affect the compression phase in laser fusion experiments through pre-heating of the fuel core. Some parametric processes lead primarily to loss of incident laser energy (stimulated Brillouin scattering) while others, such as filamentation, lead to strongly enhanced local laser intensities through the focusing of part (or all) of the laser beam into filaments of very small dimensions with a concomitant expulsion of the plasma out of these regions. So filamentation destroys the uniformity of energy deposition in the plasma and prevents high compression efficiency of the target. These interaction effects are typically of parametric nature, with their thresholds and growth rates depending critically on plasma scale lengths. Since these scale lengths increase with available laser energy and since millimeter sized plasmas are expected from reactor targets which will be used in direct drive implosion experiments, a good understanding of these processes and their saturation mechanisms becomes imperative. We report here the results on absolute energy measurements and time-resolved spectra of SRS and SBS obtained in various types of plasmas where the major changes were the inhomogeneity scale lengths. (author) 7 refs., 7 figs

  7. Precision measurement of the half-life and branching ratio of the T=1/2 mirror $\\beta$-decay of $^{37}$K

    CERN Multimedia

    We propose to study the T=1/2 mirror $\\beta$-decay of $^{37}$K. Nuclear mirror $\\beta$-decay is a competitive means to test the electroweak model by means of the high-precision measurement of V$_{ud}$ element of the CKM quark mixing matrix. One key ingredient to obtain V$_{ud}$ is the force of the transition, Ft, which has to be determined with a relative precision below 10$^{−3}$. This quantity is related to the half-life T$_{1/2}$ of the decaying nucleus, the branching ratio BR for this decay and the mass difference between the mother and daughter nucleus (Q value). Another important feature is the mixing ratio $\\rho$ between the Fermi and the Gamow-Teller character of the transition. In most cases, $\\rho$ is the major contributor to the uncertainty on Ft. Available data concerning T$_{1/2}$ and BR of $^{37}$K suffer from a lack of precision that will be easily reduced by a dedicated experiment.

  8. New limit for the half-life of double beta decay of {sup 94}Zr to the first excited state of {sup 94}Mo

    Energy Technology Data Exchange (ETDEWEB)

    Dokania, N.; Nanal, V.; Gupta, G.; Pillay, R.G.; Ghosh, C. [Tata Institute of Fundamental Research, Department of Nuclear and Atomic Physics, Mumbai (India); Pal, S. [Tata Institute of Fundamental Research, Pelletron Linac Facility, Mumbai (India); Rath, P.K. [University of Lucknow, Department of Physics, Lucknow (India); Tretyak, V.I. [Institute for Nuclear Research, Kyiv (Ukraine); Garai, A.; Krishnamoorthy, H. [Tata Institute of Fundamental Research, India-based Neutrino Observatory, Mumbai (India); Homi Bhabha National Institute, Mumbai (India); Raina, P.K. [Indian Institute of Technology, Department of Physics, Rupnagar (India); Bhushan, K.G. [Bhabha Atomic Research Centre, Technical Physics Division, Mumbai (India)

    2017-04-15

    Neutrinoless double beta decay is a phenomenon of fundamental interest in particle physics. The decay rates of double beta decay transitions to the excited states can provide input for Nuclear Transition Matrix Element calculations for the relevant two neutrino double beta decay process. It can be useful as supplementary information for the calculation of Nuclear Transition Matrix Element for the neutrinoless double beta decay process. In the present work, double beta decay of {sup 94}Zr to the 2{sup +}{sub 1} excited state of {sup 94}Mo at 871.1 keV is studied using a low background ∝ 230 cm{sup 3} HPGe detector. No evidence of this decay was found with a 232 g.y exposure of natural zirconium. The lower half-life limit obtained for the double beta decay of {sup 94}Zr to the 2{sup +}{sub 1} excited state of {sup 94}Mo is T{sub 1/2}(0ν + 2ν) > 3.4 x 10{sup 19} y at 90% C.L., an improvement by a factor of ∝ 4 over the existing experimental limit at 90% C.L. The sensitivity is estimated to be T{sub 1/2} (0ν + 2ν) > 2.0 x 10{sup 19} y at 90% C.L. using the Feldman-Cousins method. (orig.)

  9. Precision measurement of the half-life and the $\\beta$-decay Q value of the superallowed 0$^{+}\\rightarrow$ 0$^{+}\\beta$-decay of $^{38}$Ca

    CERN Multimedia

    2002-01-01

    We propose to study the $\\beta$-decay of $^{38}$Ca. In a first instance, we intend to perform a high-precision study of the half-life of this nucleus as well as a measurement of its $\\beta$-decay Q-value with ISOLTRAP. At a later stage, we propose to study its decay branches to determine the super-allowed branching ratio with high precision. These measurements are essential to improve our understanding of the theoretical corrections (in particular the $\\delta$c correction factor) needed to calculate the universal Ft value from the ft value determined for individual nuclei. For this nucleus, the correction factor is predicted to increase significantly as compared to the nine well-studied nuclei between $^{10}$C and $^{54}$Co and the model calculations used to determine the corrections, in particular the shell-model calculations, are well under control in this mass region. Therefore, the T$_{Z}$= -1 nuclei between A=18 and A=38 are ideal test cases for the correction factors which limit today the precision on t...

  10. Effective half-life of sup 131 I during treatment of autonomous thyroid disease. Untersuchungen zur effektiven Halbwertszeit des sup 131 J bei der Radiojodbehandlung der Schilddruesenautonomie

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, B.; Bares, R.; Buell, U. (Technische Hochschule Aachen (Germany, F.R.). Klinik fuer Nuklearmedizin)

    1991-06-01

    In order to compute effective half-life of {sup 131}I after application of therapeutic doses (T{sub eff}), the time course of whole-body radioactivity was evaluated retrospectively in 115 patients with benign thyroid diseases (multinodular autonomous adenoma, solitary autonomous adenoma or Graves' disease). Because of a large overlap of T{sub eff} in the various diseases analyzed, courses of all patients who did (group Ts, 24 cases) or did not (group kTs, 91 cases) receive antithyroid drugs during therapy were summarized. In group Ts a mean T{sub eff} of 5.0+-0.9 d was found which was significantly (p<0.01) lower than the mean T{sub eff} of 6.3+-0.9 d in group kTs. We believe that the mean T{sub eff} is a practical alternative in radioiodine dosimetry if an exact determination of T{sub eff} cannot be performed because of shortage of time. (orig.).

  11. Fusion to Human Serum Albumin Extends the Circulatory Half-Life and Duration of Antithrombotic Action of the Kunitz Protease Inhibitor Domain of Protease Nexin 2.

    Science.gov (United States)

    Sheffield, William P; Eltringham-Smith, Louise J; Bhakta, Varsha

    2018-01-01

    The Kunitz Protease Inhibitor (KPI) domain of protease nexin 2 (PN2) potently inhibits coagulation factor XIa. Recombinant KPI has been shown to inhibit thrombosis in mouse models, but its clearance from the murine circulation remains uncharacterized. The present study explored the pharmacokinetic and pharmacodynamic effects of fusing KPI to human serum albumin (HSA) in fusion protein KPIHSA. Hexahistidine-tagged KPI (63 amino acids) and KPIHSA (656 amino acids) were expressed in Pichia pastoris yeast and purified by nickel-chelate chromatography. Clearance profiles in mice were determined, as well as the effects of KPI or KPIHSA administration on FeCl3-induced vena cava thrombus size or carotid artery time to occlusion, respectively. Fusion to HSA increased the mean terminal half-life of KPI by 8-fold and eliminated its interaction with the low density lipoprotein receptor-related protein. KPI and KPIHSA similarly reduced thrombus size and occlusion in both venous and arterial thrombosis models when administered at the time of injury, but only KPI was effective when administered one hour before injury. Albumin fusion deflects KPI from rapid in vivo clearance without impairing its antithrombotic properties and widens its potential therapeutic window. © 2018 The Author(s). Published by S. Karger AG, Basel.

  12. Analytical model for electromagnetic radiation from a wakefield excited by intense short laser pulses in an unmagnetized plasma

    Energy Technology Data Exchange (ETDEWEB)

    Chen Ziyu; Chen Shi; Dan Jiakun; Li Jianfeng; Peng Qixian, E-mail: ziyuch@gmail.com [Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900 (China)

    2011-10-15

    A simple one-dimensional analytical model for electromagnetic emission from an unmagnetized wakefield excited by an intense short-pulse laser in the nonlinear regime has been developed in this paper. The expressions for the spectral and angular distributions of the radiation have been derived. The model suggests that the origin of the radiation can be attributed to the violent sudden acceleration of plasma electrons experiencing the accelerating potential of the laser wakefield. The radiation process could help to provide a qualitative interpretation of existing experimental results, and offers useful information for future laser wakefield experiments.

  13. Analytical model for electromagnetic radiation from a wakefield excited by intense short laser pulses in an unmagnetized plasma

    International Nuclear Information System (INIS)

    Chen Ziyu; Chen Shi; Dan Jiakun; Li Jianfeng; Peng Qixian

    2011-01-01

    A simple one-dimensional analytical model for electromagnetic emission from an unmagnetized wakefield excited by an intense short-pulse laser in the nonlinear regime has been developed in this paper. The expressions for the spectral and angular distributions of the radiation have been derived. The model suggests that the origin of the radiation can be attributed to the violent sudden acceleration of plasma electrons experiencing the accelerating potential of the laser wakefield. The radiation process could help to provide a qualitative interpretation of existing experimental results, and offers useful information for future laser wakefield experiments.

  14. Impacts of ambient and ablation plasmas on short- and ultrashort-pulse laser processing of surfaces

    Czech Academy of Sciences Publication Activity Database

    Bulgakova, Nadezhda M.; Panchenko, A.N.; Zhukov, V.P.; Kudryashov, S.I.; Pereira, A.; Marine, W.; Mocek, Tomáš; Bulgakov, A.V.

    2014-01-01

    Roč. 5, č. 4 (2014), s. 1344-1372 ISSN 2072-666X R&D Projects: GA MŠk ED2.1.00/01.0027; GA MŠk EE2.3.20.0143 Grant - others:HILASE(XE) CZ.1.05/2.1.00/01.0027; OP VK 6(XE) CZ.1.07/2.3.00/20.0143 Institutional support: RVO:68378271 Keywords : pulsed laser ablation * laser material processing * laser plasma * ambient gas breakdown * material redeposition * plasma pipe formation * microstructures Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.269, year: 2014

  15. Self-compression of intense short laser pulses in relativistic magnetized plasma

    Energy Technology Data Exchange (ETDEWEB)

    Olumi, M.; Maraghechi, B., E-mail: behrouz@aut.ac.ir [Department of Physics, Amirkabir University of Technology, Post code 15916-34311 Tehran (Iran, Islamic Republic of)

    2014-11-15

    The compression of a relativistic Gaussian laser pulse in a magnetized plasma is investigated. By considering relativistic nonlinearity and using non-linear Schrödinger equation with paraxial approximation, a second-order differential equation is obtained for the pulse width parameter (in time) to demonstrate the longitudinal pulse compression. The compression of laser pulse in a magnetized plasma can be observed by the numerical solution of the equation for the pulse width parameter. The effects of magnetic field and chirping are investigated. It is shown that in the presence of magnetic field and negative initial chirp, compression of pulse is significantly enhanced.

  16. Plasma-based creation of short light pulses: analysis and simulation of amplification and focusing

    Czech Academy of Sciences Publication Activity Database

    Riconda, C.; Weber, Stefan A.; Lancia, L.; Marqués, J.-R.; Mourou, G.; Fuchs, J.

    2015-01-01

    Roč. 57, č. 1 (2015), s. 014002 ISSN 0741-3335 R&D Projects: GA MŠk ED1.1.00/02.0061; GA MŠk EE2.3.20.0279 Grant - others:ELI Beamlines(XE) CZ.1.05/1.1.00/02.0061; LaserZdroj (OP VK 3)(XE) CZ.1.07/2.3.00/20.0279 Institutional support: RVO:68378271 Keywords : plasma-based amplification * PIC simulations * parametric instabilities Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 2.404, year: 2015

  17. Low- and high-mode separation of short wavelength turbulence in dithering Wendelstein 7-AS plasmas

    DEFF Research Database (Denmark)

    Basse, N.P.; Zoletnik, S.; Saffman, M.

    2002-01-01

    In this article measurements of small scale electron density fluctuations in dithering high confinement (H)-mode plasmas obtained by collective scattering of infrared light are presented. A scan of the fluctuation wavenumber was made in a series of similar discharges in the Wendelstein 7-AS (W7-A...

  18. Short daily hemodialysis is associated with lower plasma FGF23 levels when compared with conventional hemodialysis.

    Science.gov (United States)

    Zaritsky, Joshua; Rastogi, Anjay; Fischmann, George; Yan, Jieshi; Kleinman, Kenneth; Chow, Georgina; Gales, Barbara; Salusky, Isidro B; Wesseling-Perry, Katherine

    2014-02-01

    The utilization of short-term daily hemodialysis has increased over the last few years, but little is known on its effects on the control of serum phosphate and fibroblast growth factor 23 (FGF23) levels. We therefore performed a cross-sectional study to compare FGF23 levels as well as other biochemical variables between 24 patients undergoing short daily hemodialysis using the NxStage System® and 54 patients treated with conventional in-center hemodialysis. FGF23 levels were measured using the second-generation Immutopics® C-terminal assay. Short daily hemodialysis patients were younger than patients on conventional hemodialysis but there were no differences between groups in the duration of end-stage renal disease nor in the number of patients with residual renal function. A greater number of short daily hemodialysis patients received vitamin D sterol therapy than did conventional in-center hemodialysis patients while there were no differences in the use of different phosphate binders and calcimimetic therapy between groups. Overall serum calcium, phosphorus and intact parathyroid hormone levels were similar between groups. While serum phosphorus levels correlated with FGF23 concentrations in each group separately [r=0.522 (P<0.01) and r=0.42 (P<0.01) in short daily and conventional in-center hemodialysis, respectively], FGF23 levels were lower [823 RU/mL (263, 2169)] in the patients receiving short daily hemodialysis than in patients treated with conventional hemodialysis [2521 RU/mL (909, 5556)] (P<0.01 between groups). These findings demonstrate that FGF23 levels are significantly lower in short daily hemodialysis patients and suggest that FGF23 levels may be a more sensitive biomarker of cumulative phosphate burden than single or multiple serum phosphorus determinations in patients treated with hemodialysis.

  19. Studies on the mechanism of the epileptiform activity induced by U18666A. II. concentration, half-life and distribution of radiolabeled U18666A in the brain

    Energy Technology Data Exchange (ETDEWEB)

    Cenedella, R.J.; Sarkar, C.P.; Towns, L.

    1982-06-01

    The concentration, half-life, and distribution in brain of U18666A, a drug that can drastically alter cerebral lipids and induce a chronic epileptiform state, was determined following both acute and chronic drug administration. U18666A specifically labeled with tritium was prepared by custom synthesis. Brain levels of 1 x 10(-6)M and higher were reached soon after giving an acute 10-mg/kg dose (i.p. or s.c.) of U18666A containing 7-/sup 3/H-U18666A of known specific activity. A steady state concentration of 1 to 2 x 10(-6)M was reached with chronic injection of 10 mg/kg every 4th day, a treatment schedule that results in altered brain lipids and induction of epilepsy if begun soon after birth. The disappearance of U18666A from both brain and serum was described by two similar biexponential processes, a brief rapid clearance (t1/2 . 10 h) and a sustained and much slower one (t1/2 . 65 h). Brain levels of the drug were about 10 times higher than serum at all times examined. Few differences were seen in the regional distribution of radiolabeled drug in brain as determined by both direct analysis and by autoradiographic examination; but the drug did concentrate in lipid-rich subcellular fractions. For example, the synaptosome and myelin fractions each contained about 25-35% of both the total /sup 3/H-labeled drug and total lipid in whole brain. The lipid composition of these fractions was drastically altered in treated animals. In conclusion, the chronic epileptiform state induced by U18666A does not appear to involve localization of the drug in a specific brain region or particular cell type. Rather, the condition could involve localization of the drug in lipid-rich membranes and marked changes in the composition of these membranes.

  20. Distribution of ascorbate-2-sulfate and distribution, half-life and turnover rates of [1-14C]ascorbic acid in rainbow trout

    International Nuclear Information System (INIS)

    Tucker, B.W.; Halver, J.E.

    1984-01-01

    Rainbow trout (250 g) were maintained at 15 degrees C for 3 months on a low ascorbic acid diet, given [1- 14 C]ascorbic acid by gavage, then fed the NAS/NRC requirement 12 times per week. Total urine, fecal water and branchial water were collected daily from five fish placed in metabolism chambers for four successive 5-day periods. Tissue samples were analyzed for 14 C, ascorbic acid (C1) and ascorbate-2-sulfate (C2). Excretion analysis indicated t1/2 . 42 days. After 20 days, the feeding schedule was changed to 3 times per week. Fish fed 14 C were sampled after 1, 2, 3 and 4 months. The half-life in each organ except brain was inversely proportional to the dietary level of ascorbate. Concentrations of C1 and C2 in the various tissues reflected dietary intake of vitamin C. Total C (CT . C1 + C2) levels were maintained in the liver even with the low vitamin C diet. Estimates of body pool for C1 are 27-29 mg/kg. At the higher ascorbate intake CT was 92-114 mg/kg, but decreased by 34% at the lower feeding rate to 51-62 mg/kg. Data indicate that there are two or more body pools that include a store of C2, which is readily interconverted in metabolizing tissues to and from C1. Since air and water stable C2 is antiscorbutic for fish, it is the preferred form of ascorbate for fish feeds

  1. Effect of Truncating AUC at 12, 24 and 48 hr When Evaluating the Bioequivalence of Drugs with a Long Half-Life.

    Science.gov (United States)

    Moreno, Isabel; Ochoa, Dolores; Román, Manuel; Cabaleiro, Teresa; Abad-Santos, Francisco

    2016-01-01

    Bioequivalence studies of drugs with a long half-life require long periods of time for pharmacokinetic sampling. The latest update of the European guideline allows the area under the curve (AUC) truncated at 72 hr to be used as an alternative to AUC0-t as the primary parameter. The objective of this study was to evaluate the effect of truncating the AUC at 48, 24 and 12 hr on the acceptance of the bioequivalence criterion as compared with truncation at 72 hr in bioequivalence trials. The effect of truncated AUC on the within-individual coefficient of variation (CVw) and on the ratio of the formulations was also analysed. Twenty-eight drugs were selected from bioequivalence trials. Pharmacokinetic data were analysed using WinNonLin 2.0 based on the trapezoidal method. Analysis of variance (ANOVA) was performed to obtain the ratios and 90% confidence intervals for AUC at different time-points. The degree of agreement of AUC0-72 in relation to AUC0-48 and AUC0-24, according to the Landis and Koch classification, was 'almost perfect'. Statistically significant differences were observed when the CVw of AUC truncated at 72, 48 and 24 hr was compared with the CVw of AUC0-12. There were no statistically significant differences in the AUC ratio at any time-point. Compared to AUC0-72, Pearson's correlation coefficient for mean AUC, AUC ratio and AUC CVw was worse for AUC0-12 than AUC0-24 or AUC0-48. These preliminary results could suggest that AUC truncation at 24 or 48 hr is adequate to determine whether two formulations are bioequivalent. © 2015 Nordic Association for the Publication of BCPT (former Nordic Pharmacological Society).

  2. Contribution to the study of the plasmas created by ultra-short optical breakdown in gases

    International Nuclear Information System (INIS)

    Griesemann, J.C.

    1978-10-01

    Focussing in a gas a picosecond laser pulse leads to the plasma creation (ionization stage), energy release and the expansion of the plasma state in the surrounding gas. Experiments of spectrometry on the transmitted beam, using a frequency-to-time transposing device, show that the mechanism mainly responsible for the ionization stage involves: electron-ion collisions, the multiplication rates deduced from experiments being in good agreement with theoretical ones. The expansion stage appears as led, first by an electron thermal wave, experimental curves being correctly fit by a non adiabatic model then by a shock wave which emerges after the equipartition time. The particularities, at the early beginning, of the expansion, can be related to the dynamics of collisional ionization [fr

  3. Ultra-intense, short pulse laser-plasma interactions with applications to the fast ignitor

    Energy Technology Data Exchange (ETDEWEB)

    Wilks, S.C.; Kruer, W.L.; Young, P.E.; Hammer, J.; Tabak, M.

    1995-04-01

    Due to the advent of chirped pulse amplification (CPA) as an efficient means of creating ultra-high intensity laser light (I > 5{times}10{sup 17} W/cm{sup 2}) in pulses less than a few picoseconds, new ideas for achieving ignition and gain in DT targets with less than 1 megajoule of input energy are currently being pursued. Two types of powerful lasers are employed in this scheme: (1) channeling beams and (2) ignition beams. The current state of laser-plasma interactions relating to this fusion scheme will be discussed. In particular, plasma physics issues in the ultra-intense regime are crucial to the success of this scheme. We compare simulation and experimental results in this highly nonlinear regime.

  4. Ultra-intense, short pulse laser-plasma interactions with applications to the fast ignitor

    International Nuclear Information System (INIS)

    Wilks, S.C.; Kruer, W.L.; Young, P.E.; Hammer, J.; Tabak, M.

    1995-04-01

    Due to the advent of chirped pulse amplification (CPA) as an efficient means of creating ultra-high intensity laser light (I > 5x10 17 W/cm 2 ) in pulses less than a few picoseconds, new ideas for achieving ignition and gain in DT targets with less than 1 megajoule of input energy are currently being pursued. Two types of powerful lasers are employed in this scheme: (1) channeling beams and (2) ignition beams. The current state of laser-plasma interactions relating to this fusion scheme will be discussed. In particular, plasma physics issues in the ultra-intense regime are crucial to the success of this scheme. We compare simulation and experimental results in this highly nonlinear regime

  5. Guiding of short, intense laser pulses through solid guides and preformed plasma channels

    International Nuclear Information System (INIS)

    Borghesi, M.; Mackinnon, A.J.; Gaillard, R.; Malka, G.; Vickers, C.; Willi, O.; Blanchot, N.; Miquel, J.L.; Canaud, B.; Davies, J.R.; Malka, G.; Offenberger, A.A.

    2000-01-01

    In a series of experiments carried out at the Rutherford Appleton Laboratory, Chilton (UK) and at the Commissariat a l'Energie Atomique, Limeil (France), various techniques of guiding ultra-intense laser pulses over distances exceeding the natural diffraction length were investigated. Efficient guiding was demonstrated both through density channels formed in an underdense plasma by an intense prepulse and through solid guides (hollow capillary tubes). Indication of collimated fast electron propagation though solid targets has also been obtained. (authors)

  6. Electron transport phenomena and dense plasmas produced by ultra-short pulse laser interaction

    International Nuclear Information System (INIS)

    More, R.M.

    1994-01-01

    Recent experiments with femtosecond lasers provide a test bed for theoretical ideas about electron processes in hot dense plasmas. We briefly review aspects of electron conduction theory likely to prove relevant to femtosecond laser absorption. We show that the Mott-Ioffe-Regel limit implies a maximum inverse bremsstrahlung absorption of about 50% at temperatures near the Fermi temperature. We also propose that sheath inverse bremsstrahlung leads to a minimum absorption of 7-10% at high laser intensity

  7. Laser radiation short pulse absorption in a high-density plasma

    International Nuclear Information System (INIS)

    Brantov, A.V.; Bychenkov, V.Yu.; Tikhonchuk, V.T.

    1998-01-01

    Dependences of the absorption coefficients for s and p polarized electromagnetic waves (laser radiation) in a semi-bound plasma on the temperature and incidence angle are found for an arbitrary ratio of the skin-layer depth to the electron free path length t. The dependences obtained describe transition from the normal skin effect to abnormal one and permit quantitatively to determine the absorption coefficients in the intermediate range of the parameter t, characteristic for the majority of modern experiments

  8. Gravimetrical and chemical characterization of SiOx structures deposited on fine powders by short plasma exposure in a plasma down stream reactor

    International Nuclear Information System (INIS)

    Spillmann, Adrian; Sonnenfeld, Axel; Rohr, Philipp Rudolf von

    2008-01-01

    The surface of lactose particles was modified by a plasma-enhanced chemical vapor deposition process to improve the flow behavior of the powder. For this, the particulates were treated in a plasma down stream reactor which provides a short (50 ms) and homogeneous exposure to the capacitively coupled RF discharge. The organosilicon monomer hexamethyldisiloxane (HMDSO) was used as a precursor for the formation of SiO x which is deposited on the substrate particle surface. For varying process gas mixtures (O 2 /Ar/HMDSO) and RF power applied, the amount of the deposited material was determined gravimetrically after dissolution of the lactose substrate particles and the chemical composition of the accumulated deposition material was investigated by means of attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy. The concentration of the deposited SiO x relating to the substrate material was found to be in the range of 0.1 wt.%. Based on the ATR-FTIR analysis, the inorganic, i.e. oxidic SiO x fraction of the obtained deposits was shown to be controllable by varying the process parameters, whilst a relatively large amount of organic structures must be considered.

  9. Plasma cholesterol synthesis using deuterated water in humans: effect of short-term food restriction

    International Nuclear Information System (INIS)

    Jones, P.J.; Scanu, A.M.; Schoeller, D.A.

    1988-01-01

    Our purpose was to develop methods in humans to determine the fractional synthetic rate (FSR) of plasma pool free cholesterol using the rate of deuterium incorporation from body water. The sensitivity of this method was examined by measuring FSR after periods of fasting and feeding. Five healthy men with normal lipoprotein levels were given a prepared diet containing 40% of calories as fat and a polyunsaturated/saturated fatty acid ratio of 0.25 for 8 days, except for day 7 when they were given only drinking water. Beginning after the supper meal on day 6, they received no food until 8 AM on day 8 when they consumed meals as normal. Over days 7 and 8 the subjects were given prime and constant deuterium oxide orally to maintain body water deuterium enrichment at about 0.05 atom % excess. Plasma samples were obtained at 0 hours (day 7, 8 AM) and at 12, 24, 36, and 48 hours thereafter. Free cholesterol was extracted, purified by thin-layer chromatography, and combusted to water. The water was reduced to H 2 and analyzed for deuterium enrichment by isotope ratio mass spectrometry. Analytic precision of this system was determined as 3.5 0/00 (parts per mil) vs Standard Mean Ocean Water. Deuterium enrichment of plasma water for the group during the 48-hour deuterium oxide administration period was 3143 0/00 +/- 310 0/00 (mean +/- SEM). Cholesterol deuterium enrichment for the group during the 12-hour period of fasting (10.9 0/00 +/- 4.1 0/00) was not different from that during feeding (14.2 0/00 +/- 6.2 0/00)

  10. Supersonic Ionization Wave Driven by Radiation Transport in a Short-Pulse Laser-Produced Plasma

    International Nuclear Information System (INIS)

    Ditmire, T.; Gumbrell, E.T.; Smith, R.A.; Mountford, L.; Hutchinson, M.H.

    1996-01-01

    Through the use of an ultrashort (2ps) optical probe, we have time resolved the propagation of an ionization wave into solid fused silica. This ionization wave results when a plasma is created by the intense irradiation of a solid target with a 2ps laser pulse. We find that the velocity of the ionization wave is consistent with radiation driven thermal transport, exceeding the velocity expected from simple electron thermal conduction by nearly an order of magnitude. copyright 1996 The American Physical Society

  11. Spectral characteristics of ultra-short laser pulses in plasma amplifiers

    Czech Academy of Sciences Publication Activity Database

    Riconda, C.; Weber, Stefan A.; Lancia, L.; Marquès, J.-R.; Mourou, G.A.; Fuchs, J.

    2013-01-01

    Roč. 20, č. 8 (2013), "083115-1"-"083115-10" ISSN 1070-664X R&D Projects: GA MŠk ED1.1.00/02.0061; GA MŠk EE2.3.20.0279 Grant - others:ELI Beamlines(XE) CZ.1.05/1.1.00/02.0061; OPVK 3 Laser Zdroj(XE) CZ.1.07/2.3.00/20.0279 Program:EE Institutional support: RVO:68378271 Keywords : amplification * compression * generation * intensity * extreme * optics * light Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 2.249, year: 2013

  12. Analysis of neon soft x-ray spectra from short-pulse laser-produced plasmas

    International Nuclear Information System (INIS)

    Abare, A.C.; Keane, C.J.; Crane, J.K.; DaSilva, L.B.; Lee, R.W.; Perry, M.D.; Falcone, R.W.

    1993-04-01

    We report preliminary results from the analysis of streaked soft x-ray neon spectra a gas jet target. In obtained from the interaction of a picosecond Nd:glass laser with these experiments streaked spectra show prompt harmonic emission followed by longer time duration soft x-ray line emission. The majority of the line emission observed was found to originate from Li- and Be-like Ne and the major transitions in the observed spectra have been identified. Li-like emission lines were observed to decay faster in time than Be-like transitions, suggesting that recombination is taking place. Line ratios of n=4-2 and n=3-2 transitions supported the view that these lines were optically thin and thick, respectively. The time history of Li-like Ne 2p-4d and 2p-3d lines is in good agreement with a simple adiabatic expansion model coupled to a time dependent collisional-radiative code. Further x-ray spectroscopic analysis is underway which is aimed at diagnosing plasma conditions and assessing the potential of this recombining neon plasma as a quasi-steady-state recombination x-ray laser medium

  13. Exploratory study of plasma total homocysteine and its relationship to short-term outcome in acute ischaemic stroke in Nigerians

    Directory of Open Access Journals (Sweden)

    Awosanya Gbolahan O

    2008-07-01

    Full Text Available Abstract Background Hyperhomocysteinemia is a potentially modifiable risk factor for stroke, and may have a negative impact on the course of ischaemic stroke. The role of hyperhomocysteinemia as it relates to stroke in Africans is still uncertain. The objective of this study was to determine the prevalence and short-term impact of hyperhomocysteinemia in Nigerians with acute ischaemic stroke. We hypothesized that Hcy levels are significantly higher than in normal controls, worsen stroke severity, and increase short-term case fatality rates following acute ischaemic stroke. Methods The study employed both a case-control and prospective follow-up design to study hospitalized adults with first – ever acute ischaemic stroke presenting within 48 hours of onset. Clinical histories, neurological evaluation (including National Institutes of Health Stroke Scale (NIHSS scores on admission were documented. Total plasma Hcy was determined on fasting samples drawn from controls and stroke cases (within 24 hours of hospitalization. Outcome at 4 weeks was assessed in stroke patients using the Glasgow Outcome Scale (GOS. Results We evaluated 155 persons (69 acute ischaemic stroke and 86 healthy controls. The mean age ± SD of the cases was 58.8 ± 9.8 years, comparable to that of controls which was 58.3 ± 9.9 years (T = 0.32; P = 0.75. The mean duration of stroke (SD prior to hospitalization was 43.5 ± 38.8 hours, and mean admission NIHSS score was 10.1 ± 7.7. Total fasting Hcy in stroke patients was 10.2 ± 4.6 umol/L and did not differ significantly from controls (10.1 ± 3.6 umol/L; P = 0.88. Hyperhomocysteinemia, defined by plasma Hcy levels > 90th percentile of controls (>14.2 umol/L in women and >14.6 umol/L in men, was present in 7 (10.1% stroke cases and 11 (12.8% controls (odds ratio 0.86, 95% confidence interval 0.31 – 2.39; P > 0.05. In multiple regression analysis admission NIHSS score (but not plasma Hcy was a significant determinant of 4

  14. Characterization of the liquid argon veto of the GERDA experiment and its application for the measurement of the "7"6Ge half-life

    International Nuclear Information System (INIS)

    Wegmann, Anne Christin

    2017-01-01

    The search for neutrinoless double-beta decay (0νββ) is one of the most active fields in modern particle physics as the observation of this process would prove lepton number violation and imply new physics beyond the Standard Model of particle physics. The GERDA experiment searches for this decay by operating bare Germanium detectors, enriched in the ββ isotope "7"6Ge, in liquid argon. For the first time, a ββ-experiment combines the excellent properties of semiconductor Germanium detectors with an active background suppression technique based on the simultaneous detection of liquid argon scintillation light by photomultiplier tubes and silicon photomultipliers coupled to scintillating fibers (LAr veto). The LAr veto has been successfully operated during the first six months of Phase II of the experiment and yielded - in combination with a Germanium detector pulse shape discrimination technique - a background index of (0.7"+"1"."1_-_0_._5).10"-"3 ((cts)/(kg.keV.yr)). With an ultimate exposure of 100 kg.yr this will allow for a 0νββ-decay half-life sensitivity of the Gerda Phase II experiment of 10"2"6 yr. Double-beta decay under the emission of two neutrinos (2νββ) is a second-order process but which is allowed by the Standard Model. The excellent background reduction of the LAr veto results in an unprecedented signal-to-background ratio of 30:1 in the energy region dominated by 2νββ-decay of "7"6Ge. The remaining background after LAr veto is estimated using the suppression factor from calibration source measurements and results in a measurement of T"2"ν_1_/_2=(1.98±0.02(stat)±0.05(syst)).10"2"1 yr and T_1_/_2"2"ν=(1.92 ±0.02(stat)±0.11(syst)).10"2"1 yr based on two different detector designs and give uncertainties on the detector parameters but both with improved systematic uncertainties in comparison to earlier measurements.

  15. Characterization of the liquid argon veto of the GERDA experiment and its application for the measurement of the {sup 76}Ge half-life

    Energy Technology Data Exchange (ETDEWEB)

    Wegmann, Anne Christin

    2017-01-18

    The search for neutrinoless double-beta decay (0νββ) is one of the most active fields in modern particle physics as the observation of this process would prove lepton number violation and imply new physics beyond the Standard Model of particle physics. The GERDA experiment searches for this decay by operating bare Germanium detectors, enriched in the ββ isotope {sup 76}Ge, in liquid argon. For the first time, a ββ-experiment combines the excellent properties of semiconductor Germanium detectors with an active background suppression technique based on the simultaneous detection of liquid argon scintillation light by photomultiplier tubes and silicon photomultipliers coupled to scintillating fibers (LAr veto). The LAr veto has been successfully operated during the first six months of Phase II of the experiment and yielded - in combination with a Germanium detector pulse shape discrimination technique - a background index of (0.7{sup +1.1}{sub -0.5}).10{sup -3} ((cts)/(kg.keV.yr)). With an ultimate exposure of 100 kg.yr this will allow for a 0νββ-decay half-life sensitivity of the Gerda Phase II experiment of 10{sup 26} yr. Double-beta decay under the emission of two neutrinos (2νββ) is a second-order process but which is allowed by the Standard Model. The excellent background reduction of the LAr veto results in an unprecedented signal-to-background ratio of 30:1 in the energy region dominated by 2νββ-decay of {sup 76}Ge. The remaining background after LAr veto is estimated using the suppression factor from calibration source measurements and results in a measurement of T{sup 2ν}{sub 1/2}=(1.98±0.02(stat)±0.05(syst)).10{sup 21} yr and T{sub 1/2}{sup 2ν}=(1.92 ±0.02(stat)±0.11(syst)).10{sup 21} yr based on two different detector designs and give uncertainties on the detector parameters but both with improved systematic uncertainties in comparison to earlier measurements.

  16. Pulse shape analysis for the GERDA experiment to set a new limit on the half-life of 0νββ decay of {sup 76}Ge

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Victoria Elisabeth

    2017-01-25

    The GERDA experiment searches for neutrinoless double beta (0νββ) decay of {sup 76}Ge using high purity germanium (HPGe) detectors operated in liquid argon (LAr). The aim is to explore half-lives of the order of 10{sup 26} yr. Therefore, GERDA relies on improved active background reduction techniques such as pulse shape discrimination (PSD) in which the time structure of the germanium signals is analyzed to discriminate signal- from background-like events. Two types of HPGe detectors are operated: semi-coaxial detectors previously used in the Heidelberg-Moscow and IGEX experiments and new Broad Energy Germanium (BEGe) detectors which feature an improved energy resolution and enhanced PSD. In Phase I of the experiment, five enriched BEGe detectors were used for the first time in the search for 0νββ decay. A PSD based on a single parameter, the ratio of the maximum current amplitude over the energy A/E is applied. 83% of the background events in a 232 keV region around Q{sub ββ} are rejected with a high signal efficiency of (92.1 ± 1.9) %. The achieved background index (BI) is (5.4{sup +4.1}{sub -3.4}) . 10{sup -3} (counts)/(keV.kg.yr). This is an improvement by a factor of 10 compared to previous germanium based 0νββ experiments. Phase II of the experiment includes a major upgrade: for further background rejection, the LAr cryostat is instrumented to detect argon scintillation light. Additional 25 BEGe detectors are installed. After PSD and LAr veto a BI of (0.7{sup +1.3}{sub -0.5}) . 10{sup -3} (counts)/(keV.kg.yr) is achieved. This is the best BI achieved in 0νββ experiments so far. A frequentist statistical analysis is performed on the combined data collected in GERDA Phase I and the first Phase II release. A new limit on the half-life of 0νββ decay of {sup 76}Ge is set to T{sup 0ν}{sub 1/2}>5.3.10{sup 25} yr at 90% C.L., with a median sensitivity of T{sup 0ν}{sub 1/2}>4.0.10{sup 25} yr at 90% C.L.

  17. Emission Characteristics of Laser-Induced Plasma Using Collinear Long and Short Dual-Pulse Laser-Induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Wang, Zhenzhen; Deguchi, Yoshihiro; Liu, Renwei; Ikutomo, Akihiro; Zhang, Zhenzhen; Chong, Daotong; Yan, Junjie; Liu, Jiping; Shiou, Fang-Jung

    2017-09-01

    Collinear long and short dual-pulse laser-induced breakdown spectroscopy (DP-LIBS) was employed to clarify the emission characteristics from laser-induced plasma. The plasma was sustained and became stable by the long pulse-width laser with the pulse width of 60 μs under free running (FR) conditions as an external energy source. Comparing the measurement results of stainless steel in air using single-pulse LIBS (SP-LIBS) and DP-LIBS, the emission intensity was markedly enhanced using DP-LIBS. The temperature of plasma induced by DP-LIBS was maintained at a higher temperature under different gate delay time and short pulse-width laser power conditions compared with those measured using short SP-LIBS. Moreover, the variation rates of plasma temperatures measured using DP-LIBS were also lower. The superior detection ability was verified by the measurement of aluminum sample in water. The spectra were clearly detected using DP-LIBS, whereas it cannot be identified using SP-LIBS of short and long pulse widths. The effects of gate delay time and short pulse-width laser power were also discussed. These results demonstrate the feasibility and enhanced detection ability of the proposed collinear long and short DP-LIBS method.

  18. Sub-grid-scale effects on short-wave instability in magnetized hall-MHD plasma

    International Nuclear Information System (INIS)

    Miura, H.; Nakajima, N.

    2010-11-01

    Aiming to clarify effects of short-wave modes on nonlinear evolution/saturation of the ballooning instability in the Large Helical Device, fully three-dimensional simulations of the single-fluid MHD and the Hall MHD equations are carried out. A moderate parallel heat conductivity plays an important role both in the two kinds of simulations. In the single-fluid MHD simulations, the parallel heat conduction effectively suppresses short-wave ballooning modes but it turns out that the suppression is insufficient in comparison to an experimental result. In the Hall MHD simulations, the parallel heat conduction triggers a rapid growth of the parallel flow and enhance nonlinear couplings. A comparison between single-fluid and the Hall MHD simulations reveals that the Hall MHD model does not necessarily improve the saturated pressure profile, and that we may need a further extension of the model. We also find by a comparison between two Hall MHD simulations with different numerical resolutions that sub-grid-scales of the Hall term should be modeled to mimic an inverse energy transfer in the wave number space. (author)

  19. Time-resolved plasma spectroscopy of thin foils heated by a relativistic-intensity short-pulse laser

    International Nuclear Information System (INIS)

    Audebert, P.; Gauthier, J.-C.; Shepherd, R.; Fournier, K.B.; Price, D.; Lee, R.W.; Springer, P.; Peyrusse, O.; Klein, L.

    2002-01-01

    Time-resolved K-shell x-ray spectra are recorded from sub-100 nm aluminum foils irradiated by 150-fs laser pulses at relativistic intensities of Iλ 2 =2x10 18 W μm 2 /cm 2 . The thermal penetration depth is greater than the foil thickness in these targets so that uniform heating takes place at constant density before hydrodynamic motion occurs. The high-contrast, high-intensity laser pulse, broad spectral band, and short time resolution utilized in this experiment permit a simplified interpretation of the dynamical evolution of the radiating matter. The observed spectrum displays two distinct phases. At early time, ≤500 fs after detecting target emission, a broad quasicontinuous spectral feature with strong satellite emission from multiply excited levels is seen. At a later time, the He-like resonance line emission is dominant. The time-integrated data is in accord with previous studies with time resolution greater than 1 ps. The early time satellite emission is shown to be a signature of an initial large area, high density, low-temperature plasma created in the foil by fast electrons accelerated by the intense radiation field in the laser spot. We conclude that, because of this early time phenomenon and contrary to previous predictions, a short, high-intensity laser pulse incident on a thin foil does not create a uniform hot and dense plasma. The heating mechanism has been studied as a function of foil thickness, laser pulse length, and intensity. In addition, the spectra are found to be in broad agreement with a hydrodynamic expansion code postprocessed by a collisional-radiative model based on superconfiguration average rates and on the unresolved transition array formalism

  20. A new method for detection of the electron temperature in laser-plasma short wave cut off of stimulated Raman scattering spectrum

    International Nuclear Information System (INIS)

    Zhang Jiatai

    1994-01-01

    From the theory of stimulated Raman scattering (SRS) three wave interaction, a new method of detecting the electron temperature in laser-plasma is obtained. SRS spectrum obtained from Shenguang No. 12 Nd-laser experiments are analysed. Using the wave length of short wave cut off of SRS, the electron temperature in corona plasma region is calculated consistently. These results agree reasonable with X-ray spectrum experiments

  1. Efficient soft x-ray generation in short wavelength laser produced plasmas

    International Nuclear Information System (INIS)

    Mochizuki, T.; Yamanaka, C.

    1987-01-01

    Intense x-ray generation in 1.053, 0.53, 0.26 μm laser-produced plasma has been investigated in the photon energy range of 0.1 to 3keV. The x-ray spectrum is found to have several humps which move to the higher energy side as the atomic number of the target increases. This atomic dependence is explained by a semi-Moseley's law and allows us to predict a target material most suitable for generating the photons of desired energies. Conversion efficiencies of 1.5 -- 3keV x-rays are obtained also as a function of laser wavelength at the intensity of 10/sup 13/W/cm/sup 2/. The conversion efficiency of keV x rays has been enhanced by a factor of 2 -- 3 with a controlled prepulse laser. From the semi-Moseley's law we find that cryogenic targets using either Xe or Kr in a liquid or solid phase may be most useful for a number of applications because they radiate 1 -- 3 keV x rays efficiently and never deposit on the x-ray optical components and the objects to be exposed

  2. Short-wavelength out-of-band EUV emission from Sn laser-produced plasma

    Science.gov (United States)

    Torretti, F.; Schupp, R.; Kurilovich, D.; Bayerle, A.; Scheers, J.; Ubachs, W.; Hoekstra, R.; Versolato, O. O.

    2018-02-01

    We present the results of spectroscopic measurements in the extreme ultraviolet regime (7-17 nm) of molten tin microdroplets illuminated by a high-intensity 3 J, 60 ns Nd:YAG laser pulse. The strong 13.5 nm emission from this laser-produced plasma (LPP) is of relevance for next-generation nanolithography machines. Here, we focus on the shorter wavelength features between 7 and 12 nm which have so far remained poorly investigated despite their diagnostic relevance. Using flexible atomic code calculations and local thermodynamic equilibrium arguments, we show that the line features in this region of the spectrum can be explained by transitions from high-lying configurations within the Sn{}8+-Sn{}15+ ions. The dominant transitions for all ions but Sn{}8+ are found to be electric-dipole transitions towards the n = 4 ground state from the core-excited configuration in which a 4p electron is promoted to the 5s subshell. Our results resolve some long-standing spectroscopic issues and provide reliable charge state identification for Sn LPP, which could be employed as a useful tool for diagnostic purposes.

  3. Plasma metabolomic profiles of breast cancer patients after short-term limonene intervention.

    Science.gov (United States)

    Miller, Jessica A; Pappan, Kirk; Thompson, Patricia A; Want, Elizabeth J; Siskos, Alexandros P; Keun, Hector C; Wulff, Jacob; Hu, Chengcheng; Lang, Julie E; Chow, H-H Sherry

    2015-01-01

    Limonene is a lipophilic monoterpene found in high levels in citrus peel. Limonene demonstrates anticancer properties in preclinical models with effects on multiple cellular targets at varying potency. While of interest as a cancer chemopreventive, the biologic activity of limonene in humans is poorly understood. We conducted metabolite profiling in 39 paired (pre/postintervention) plasma samples from early-stage breast cancer patients receiving limonene treatment (2 g QD) before surgical resection of their tumor. Metabolite profiling was conducted using ultra-performance liquid chromatography coupled to a linear trap quadrupole system and gas chromatography-mass spectrometry. Metabolites were identified by comparison of ion features in samples to a standard reference library. Pathway-based interpretation was conducted using the human metabolome database and the MetaCyc database. Of the 397 named metabolites identified, 72 changed significantly with limonene intervention. Class-based changes included significant decreases in adrenal steroids (P limonene resulted in significant changes in several metabolic pathways. Furthermore, pathway-based changes were related to the change in tissue level cyclin D1 expression. Future controlled clinical trials with limonene are necessary to determine the potential role and mechanisms of limonene in the breast cancer prevention setting. ©2014 American Association for Cancer Research.

  4. Short-term effects of air temperature on plasma metabolite concentrations in patients undergoing cardiac catheterization

    International Nuclear Information System (INIS)

    Hampel, Regina; Breitner, Susanne; Kraus, William E.; Hauser, Elizabeth; Shah, Svati; Ward-Caviness, Cavin K.; Devlin, Robert; Diaz-Sanchez, David; Neas, Lucas; Cascio, Wayne; Peters, Annette; Schneider, Alexandra

    2016-01-01

    Background: Epidemiological studies have shown associations between air temperature and cardiovascular health outcomes. Metabolic dysregulation might also play a role in the development of cardiovascular disease. Objectives: To investigate short-term temperature effects on metabolites related to cardiovascular disease. Methods: Concentrations of 45 acylcarnitines, 15 amino acids, ketone bodies and total free fatty acids were available in 2869 participants from the CATHeterization GENetics cohort recruited at the Duke University Cardiac Catheterization Clinic (Durham, NC) between 2001 and 2007. Ten metabolites were selected based on quality criteria and cluster analysis. Daily averages of meteorological variables were obtained from the North American Regional Reanalysis project. Immediate, lagged, and cumulative temperature effects on metabolite concentrations were analyzed using (piecewise) linear regression models. Results: Linear temperature effects were found for glycine, C16-OH:C14:1-DC, and aspartic acid/asparagine. A 5 °C increase in temperature was associated with a 1.8% [95%-confidence interval: 0.3%; 3.3%] increase in glycine (5-day average), a 3.2% [0.1%; 6.3%] increase in C16-OH:C14:1-DC (lag of four days), and a −1.4% [−2.4%; −0.3%] decrease in aspartic acid/asparagine (lag of two days). Non-linear temperature effects were observed for alanine and total ketone bodies with breakpoint of 4 °C and 20 °C, respectively. Both a 5 °C decrease in temperature on colder days (<4 °C)and a 5 °C increase in temperature on warmer days (≥4 °C) were associated with a four day delayed increase in alanine by 6.6% [11.7; 1.8%] and 1.9% [0.3%; 3.4%], respectively. For ketone bodies we found immediate (0-day lag) increases of 4.2% [−0.5%; 9.1%] and 12.3% [0.1%; 26.0%] associated with 5 °C decreases on colder (<20 °C) days and 5 °C increases on warmer days (≥20 °C), respectively. Conclusions: We observed multiple effects of air temperature on

  5. Short-term effects of air temperature on plasma metabolite concentrations in patients undergoing cardiac catheterization

    Energy Technology Data Exchange (ETDEWEB)

    Hampel, Regina, E-mail: regina.hampel@helmholtz-muenchen.de [Institute of Epidemiology II, Helmholtz Zentrum München, German Research Center for Environmental Health (GmbH), Ingolstädter Landstraße 1, 85764 Neuherberg (Germany); Breitner, Susanne [Institute of Epidemiology II, Helmholtz Zentrum München, German Research Center for Environmental Health (GmbH), Ingolstädter Landstraße 1, 85764 Neuherberg (Germany); Kraus, William E. [School of Medicine, Duke University, Durham, NC 27701 (United States); Hauser, Elizabeth [School of Medicine, Duke University, Durham, NC 27701 (United States); Duke Molecular Physiology Institute, 300 North Duke Street, Durham, NC 27701 (United States); Cooperative Studies Program Epidemiology Center-Durham, Veterans Affairs Medical Center, Durham, NC 27701 (United States); Shah, Svati [School of Medicine, Duke University, Durham, NC 27701 (United States); Ward-Caviness, Cavin K. [Institute of Epidemiology II, Helmholtz Zentrum München, German Research Center for Environmental Health (GmbH), Ingolstädter Landstraße 1, 85764 Neuherberg (Germany); Devlin, Robert; Diaz-Sanchez, David; Neas, Lucas; Cascio, Wayne [National Health and Environmental Effects Research Laboratory, US Environmental Protection Agency, Research Triangle Park, 109 T.W. Alexander Drive, Durham, NC 27709 (United States); Peters, Annette; Schneider, Alexandra [Institute of Epidemiology II, Helmholtz Zentrum München, German Research Center for Environmental Health (GmbH), Ingolstädter Landstraße 1, 85764 Neuherberg (Germany)

    2016-11-15

    Background: Epidemiological studies have shown associations between air temperature and cardiovascular health outcomes. Metabolic dysregulation might also play a role in the development of cardiovascular disease. Objectives: To investigate short-term temperature effects on metabolites related to cardiovascular disease. Methods: Concentrations of 45 acylcarnitines, 15 amino acids, ketone bodies and total free fatty acids were available in 2869 participants from the CATHeterization GENetics cohort recruited at the Duke University Cardiac Catheterization Clinic (Durham, NC) between 2001 and 2007. Ten metabolites were selected based on quality criteria and cluster analysis. Daily averages of meteorological variables were obtained from the North American Regional Reanalysis project. Immediate, lagged, and cumulative temperature effects on metabolite concentrations were analyzed using (piecewise) linear regression models. Results: Linear temperature effects were found for glycine, C16-OH:C14:1-DC, and aspartic acid/asparagine. A 5 °C increase in temperature was associated with a 1.8% [95%-confidence interval: 0.3%; 3.3%] increase in glycine (5-day average), a 3.2% [0.1%; 6.3%] increase in C16-OH:C14:1-DC (lag of four days), and a −1.4% [−2.4%; −0.3%] decrease in aspartic acid/asparagine (lag of two days). Non-linear temperature effects were observed for alanine and total ketone bodies with breakpoint of 4 °C and 20 °C, respectively. Both a 5 °C decrease in temperature on colder days (<4 °C)and a 5 °C increase in temperature on warmer days (≥4 °C) were associated with a four day delayed increase in alanine by 6.6% [11.7; 1.8%] and 1.9% [0.3%; 3.4%], respectively. For ketone bodies we found immediate (0-day lag) increases of 4.2% [−0.5%; 9.1%] and 12.3% [0.1%; 26.0%] associated with 5 °C decreases on colder (<20 °C) days and 5 °C increases on warmer days (≥20 °C), respectively. Conclusions: We observed multiple effects of air temperature on

  6. Real-time RT-PCR analysis of mRNA decay: half-life of Beta-actin mRNA in human leukemia CCRF-CEM and Nalm-6 cell lines

    Directory of Open Access Journals (Sweden)

    Barredo Julio C

    2002-03-01

    Full Text Available Abstract Background We describe an alternative method to determine mRNA half-life (t1/2 based on the Real-Time RT-PCR procedure. This approach was evaluated by using the β-actin gene as a reference molecule for measuring of mRNA stability. Results Human leukemia Nalm-6 and CCRF-CEM cells were treated with various concentrations of Actinomycin D to block transcription and aliquots were removed periodically. Total RNA was isolated and quantified using the RiboGreen® fluorescent dye with the VersaFluor Fluorometer System. One μg of total RNA was reverse transcribed and used as template for the amplification of a region of the β-actin gene (231 bp. To generate the standard curve, serial ten-fold dilutions of the pBactin-231 vector containing the cDNA amplified fragment were employed, β-actin mRNAs were quantified by Real-Time RT-PCR using the SYBR® Green I fluorogenic dye and data analyzed using the iCycle iQ system software. Using this method, the β-actin mRNA exhibited a half-life of 6.6 h and 13.5 h in Nalm-6 and CCRF-CEM cells, respectively. The t1/2 value obtained for Nalm-6 is comparable to those estimated from Northern blot studies, using normal human leukocytes (5.5 h. Conclusions We have developed a rapid, sensitive, and reliable method based on Real-Time RT-PCR for measuring mRNA half-life. Our results confirm that β-actin mRNA half-life can be affected by the cellular growth rate.

  7. Effect of pulse slippage on resonant second harmonic generation of a short pulse laser in a plasma

    International Nuclear Information System (INIS)

    Nitikant; Sharma, A K

    2004-01-01

    The process of second harmonic generation of an intense short pulse laser in a plasma is resonantly enhanced by the application of a magnetic wiggler. The wiggler of suitable wave number k-vector 0 provides necessary momentum to second harmonic photons to make harmonic generation a resonant process. The laser imparts an oscillatory velocity to electrons and exerts a longitudinal ponderomotive force on them at (2ω 1 ,2k-vector 1 ), where ω 1 and k-vector 1 are the frequency and the wave number of the laser, respectively. As the electrons acquire oscillatory velocity at the second harmonic, the wiggler magnetic field beats with it to produce a transverse second harmonic current at (2ω 1 ,2k-vector 1 +k-vector 0 ), driving the second harmonic electromagnetic radiation. However, the group velocity of the second harmonic wave is greater than that of the fundamental wave, hence, the generated pulse slips out of the main laser pulse and its amplitude saturates

  8. Prediction of short-term changes in symptom severity by baseline plasma homovanillic acid levels in schizophrenic patients receiving clozapine.

    Science.gov (United States)

    Sumiyoshi, T; Hasegawa, M; Jayathilake, K; Meltzer, H Y

    1997-03-24

    The relationship between pretreatment levels of plasma homovanillic acid (pHVA) and the outcome of clozapine treatment was studied in 18 male patients with schizophrenia who were resistant to treatment with conventional neuroleptics. After 6 months of clozapine treatment, 7 patients demonstrated > or = 20% decrease in the Brief Psychiatric Rating Scale (BPRS) (responders), while 11 patients did not (non-responders). Responders and non-responders did not differ with respect to the baseline pHVA level. The BPRS Positive Symptom scores at 6 weeks and 3 months, but not those at baseline and 6 months, following initiation of clozapine treatment negatively correlated with pHVA levels for all patients. The correlations became stronger when only responders were included. No significant correlation between Positive Symptom scores and pHVA levels was observed for non-responders. The BPRS Total and Negative Symptom scores did not correlate with pHVA for all patients, responders or non-responders at any time. The percent decrease in the BPRS Positive Symptom scores from baseline at 6 weeks following clozapine treatment correlated significantly with pHVA levels in responders. These results suggest that pretreatment levels of pHVA can be used to predict relatively short-term changes in the positive symptoms of patients with schizophrenia receiving clozapine treatment, particularly for clozapine responders.

  9. Kinetic study on non-thermal volumetric plasma decay in the early afterglow of air discharge generated by a short pulse microwave or laser

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Wei, E-mail: yangwei861212@126.com; Zhou, Qianhong; Dong, Zhiwei [Institute of Applied Physics and Computational Mathematics, Beijing 100094 (China)

    2016-08-28

    This paper reports a kinetic study on non-thermal plasma decay in the early afterglow of air discharge generated by short pulse microwave or laser. A global self-consistent model is based on the particle balance of complex plasma chemistry, electron energy equation, and gas thermal balance equation. Electron-ion Coulomb collision is included in the steady state Boltzmann equation solver to accurately describe the electron mobility and other transport coefficients. The model is used to simulate the afterglow of microsecond to nanosecond pulse microwave discharge in N{sub 2}, O{sub 2}, and air, as well as femtosecond laser filament discharge in dry and humid air. The simulated results for electron density decay are in quantitative agreement with the available measured ones. The evolution of plasma decay under an external electric field is also investigated, and the effect of gas heating is considered. The underlying mechanism of plasma density decay is unveiled through the above kinetic modeling.

  10. Anti-tau antibody administration increases plasma tau in transgenic mice and patients with tauopathy

    Science.gov (United States)

    Yanamandra, Kiran; Patel, Tirth K.; Jiang, Hong; Schindler, Suzanne; Ulrich, Jason D.; Boxer, Adam L.; Miller, Bruce L.; Kerwin, Diana R.; Gallardo, Gilbert; Stewart, Floy; Finn, Mary Beth; Cairns, Nigel J.; Verghese, Philip B.; Fogelman, Ilana; West, Tim; Braunstein, Joel; Robinson, Grace; Keyser, Jennifer; Roh, Joseph; Knapik, Stephanie S.; Hu, Yan; Holtzman, David M.

    2017-01-01

    Tauopathies are a group of disorders in which the cytosolic protein tau aggregates and accumulates in cells within the brain, resulting in neurodegeneration. A promising treatment being explored for tauopathies is passive immunization with anti-tau antibodies. We previously found that administration of an anti-tau antibody to human tau transgenic mice increased the concentration of plasma tau. We further explored the effects of administering an anti-tau antibody on plasma tau. After peripheral administration of an anti-tau antibody to human patients with tauopathy and to mice expressing human tau in the central nervous system, there was a dose-dependent increase in plasma tau. In mouse plasma, we found that tau had a short half-life of 8 min that increased to more than 3 hours after administration of anti-tau antibody. As tau transgenic mice accumulated insoluble tau in the brain, brain soluble and interstitial fluid tau decreased. Administration of anti-tau antibody to tau transgenic mice that had decreased brain soluble tau and interstitial fluid tau resulted in an increase in plasma tau, but this increase was less than that observed in tau transgenic mice without these brain changes. Tau transgenic mice subjected to acute neuronal injury using 3-nitropropionic acid showed increased interstitial fluid tau and plasma tau. These data suggest that peripheral administration of an anti-tau antibody results in increased plasma tau, which correlates with the concentration of extracellular and soluble tau in the brain. PMID:28424326

  11. Plasma PCSK9 concentrations during an oral fat load and after short term high-fat, high-fat high-protein and high-fructose diets

    Directory of Open Access Journals (Sweden)

    Cariou Bertrand

    2013-01-01

    Full Text Available Abstract Background PCSK9 (Proprotein Convertase Subtilisin Kexin type 9 is a circulating protein that promotes hypercholesterolemia by decreasing hepatic LDL receptor protein. Under non interventional conditions, its expression is driven by sterol response element binding protein 2 (SREBP2 and follows a diurnal rhythm synchronous with cholesterol synthesis. Plasma PCSK9 is associated to LDL-C and to a lesser extent plasma triglycerides and insulin resistance. We aimed to verify the effect on plasma PCSK9 concentrations of dietary interventions that affect these parameters. Methods We performed nutritional interventions in young healthy male volunteers and offspring of type 2 diabetic (OffT2D patients that are more prone to develop insulin resistance, including: i acute post-prandial hyperlipidemic challenge (n=10, ii 4 days of high-fat (HF or high-fat/high-protein (HFHP (n=10, iii 7 (HFruc1, n=16 or 6 (HFruc2, n=9 days of hypercaloric high-fructose diets. An acute oral fat load was also performed in two patients bearing the R104C-V114A loss-of-function (LOF PCSK9 mutation. Plasma PCSK9 concentrations were measured by ELISA. For the HFruc1 study, intrahepatocellular (IHCL and intramyocellular lipids were measured by 1H magnetic resonance spectroscopy. Hepatic and whole-body insulin sensitivity was assessed with a two-step hyperinsulinemic-euglycemic clamp (0.3 and 1.0 mU.kg-1.min-1. Findings HF and HFHP short-term diets, as well as an acute hyperlipidemic oral load, did not significantly change PCSK9 concentrations. In addition, post-prandial plasma triglyceride excursion was not altered in two carriers of PCSK9 LOF mutation compared with non carriers. In contrast, hypercaloric 7-day HFruc1 diet increased plasma PCSK9 concentrations by 28% (p=0.05 in healthy volunteers and by 34% (p=0.001 in OffT2D patients. In another independent study, 6-day HFruc2 diet increased plasma PCSK9 levels by 93% (p Conclusions Plasma PCSK9 concentrations vary

  12. Background-free beta-decay half-life measurements by in-trap decay and high-resolution MR-ToF mass analysis

    Science.gov (United States)

    Wolf, R. N.; Atanasov, D.; Blaum, K.; Kreim, S.; Lunney, D.; Manea, V.; Rosenbusch, M.; Schweikhard, L.; Welker, A.; Wienholtz, F.; Zuber, K.

    2016-06-01

    In-trap decay in ISOLTRAP's radiofrequency quadrupole (RFQ) ion beam cooler and buncher was used to determine the lifetime of short-lived nuclides. After various storage times, the remaining mother nuclides were mass separated from accompanying isobaric contaminations by the multi-reflection time-of-flight mass separator (MR-ToF MS), allowing for a background-free ion counting. A feasibility study with several online measurements shows that the applications of the ISOLTRAP setup can be further extended by exploiting the high resolving power of the MR-ToF MS in combination with in-trap decay and single-ion counting.

  13. Teduglutide for the treatment of short bowel syndrome

    DEFF Research Database (Denmark)

    Jeppesen, P B

    2013-01-01

    Glucagon-like peptide 2 (GLP-2) decreases gastric and intestinal motility, reduces gastric secretions, promotes intestinal growth and improves post-resection structural and functional adaptation in short bowel syndrome (SBS). Teduglutide, an analogue of GLP-2, has a prolonged half-life and provides...

  14. Whole-genome analysis of mRNA decay in Plasmodium falciparum reveals a global lengthening of mRNA half-life during the intra-erythrocytic development cycle.

    Science.gov (United States)

    Shock, Jennifer L; Fischer, Kael F; DeRisi, Joseph L

    2007-01-01

    The rate of mRNA decay is an essential element of post-transcriptional regulation in all organisms. Previously, studies in several organisms found that the specific half-life of each mRNA is precisely related to its physiologic role, and plays an important role in determining levels of gene expression. We used a genome-wide approach to characterize mRNA decay in Plasmodium falciparum. We found that, globally, rates of mRNA decay increase dramatically during the asexual intra-erythrocytic developmental cycle. During the ring stage of the cycle, the average mRNA half-life was 9.5 min, but this was extended to an average of 65 min during the late schizont stage of development. Thus, a major determinant of mRNA decay rate appears to be linked to the stage of intra-erythrocytic development. Furthermore, we found specific variations in decay patterns superimposed upon the dominant trend of progressive half-life lengthening. These variations in decay pattern were frequently enriched for genes with specific cellular functions or processes. Elucidation of Plasmodium mRNA decay rates provides a key element for deciphering mechanisms of genetic control in this parasite, by complementing and extending previous mRNA abundance studies. Our results indicate that progressive stage-dependent decreases in mRNA decay rate function are a major determinant of mRNA accumulation during the schizont stage of intra-erythrocytic development. This type of genome-wide change in mRNA decay rate has not been observed in any other organism to date, and indicates that post-transcriptional regulation may be the dominant mechanism of gene regulation in P. falciparum.

  15. Sub-nanosecond Half-life Measurement of the Yrast I{sup π}=5{sup −} State in the N=78 Nucleus {sup 136}{sub 58}Ce using Fast-timing Coincident Gamma-ray Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Alharbi, T. [Department of Physics, University of Surrey, Guildford, GU2 7XH (United Kingdom); Department of Physics, Faculty of Science in Zulfi, Almajmaah University, P.O. Box 1712, 11932 (Saudi Arabia); Regan, P.H., E-mail: p.regan@surrey.ac.uk [Department of Physics, University of Surrey, Guildford, GU2 7XH (United Kingdom); National Physical Laboratory, Teddington, Middlesex, TW11 0LW (United Kingdom); Mărginean, N. [Horia Hulubei – National Institute for Physics and Nuclear Engineering (IFIN-HH), Bucharest (Romania); Podolyák, Zs.; Bajoga, A.; Britton, R. [Department of Physics, University of Surrey, Guildford, GU2 7XH (United Kingdom); Bucurescu, D.; Deleanu, D.; Filipescu, D.; Ghită, D.; Glodariu, T.; Mihai, C. [Horia Hulubei – National Institute for Physics and Nuclear Engineering (IFIN-HH), Bucharest (Romania); Mulholland, K. [School of Engineering, University of the West of Scotland, High Street, Paisley PA1 2BE (United Kingdom); Mărginean, R.; Negret, A.; Nita, C.R. [Horia Hulubei – National Institute for Physics and Nuclear Engineering (IFIN-HH), Bucharest (Romania); Patel, Z. [Department of Physics, University of Surrey, Guildford, GU2 7XH (United Kingdom); Roberts, O.J. [School of Computing Engineering and Mathematics, University of Brighton, Brighton, BN2 4GJ (United Kingdom); Stroe, L.; Sava, T. [Horia Hulubei – National Institute for Physics and Nuclear Engineering (IFIN-HH), Bucharest (Romania); and others

    2014-06-15

    We report on the measurement of the half-life of the yrast I{sup π}=5{sup −} state in the transitional nucleus {sup 136}Ce using a combined HPGe-LaBr3(Ce) scintillator gamma-ray detection array. The measured value for the E1 decay is approximately half a nanosecond, which corresponds to an E1 decay strength of approximately 2×10{sup −6} Wu. This value is in line with single-particle type E1 decays in this mass region and suggests no sign of additional K-hindrance associated with axially symmetric quadrupole deformations observed for lighter cerium isotopes.

  16. Mechanism for the generation of 109 G magnetic fields in the interaction of ultraintense short laser pulse with an overdense plasma target

    International Nuclear Information System (INIS)

    Sudan, R.N.

    1993-01-01

    The physical mechanism for the generation of very high ''dc'' magnetic fields in the interaction of ultraintense short laser pulse with an overdense plasma target originates in the spatial gradients and nonstationary character of the ponderomotive force. A set of model equations to determine the evolution of the ''dc'' fields is derived and it is shown that the ''dc'' magnetic field is of the same order of magnitude as the high frequency laser magnetic field

  17. The biochemical mechanisms responsible for differences in the half-life of monomeric 239Pu in rat and Syrian hamster liver

    International Nuclear Information System (INIS)

    Seidel, A.; Winter, R.; Jentzsch, C.; Gruner, R.; Heumann, H.G.; Hanke, S.

    1979-01-01

    The subcellular distribution of 239 Pu citrate in rat and Syrian hamster liver was studied with the help of the non-ionic detergent Triton WR1339, used as method for separating lysosomes from other cell organelles. Triton WR1339 was injected six days after 239 Pu and the animals were sacrificed after Day 10. Liver homogenates were subjected to differential and isopycnic centrifugation in sucrose gradients. In both animal species 90% of 239 Pu of the post-nuclear supernatant was found in the fraction containing mitochondria, lysosomes, endoplasmatic reticulum and ferritin. Triton WR1339 injection caused a concomitant shift of the lysosomal marker acid phosphatase and of 239 Pu from high densities to rho approximately 1.10 in both animal species. According to our results, binding of 239 Pu to mitochondria and peroxisomes can be excluded, and association to endoplasmatic reticulum and plasma membranes is not very probable. We must consider the possibility that a part of the radioactivity occurring at rho approximately 1.10 can also be bound to ferritin. According to these findings, lysosomes could be one of the main storage sites for 239 Pu in both species. From studies on the pharmacokinetics of 3 H-labelled Triton WR1339 and on the behaviour of Triton-filled rat liver lysosomes, which are also presented in the paper, it is tentatively concluded that the rapid excretion of 239 Pu from rat liver is due to the normally rapid elimination of lysosomal material from hepatocytes into the bile in this species. In Syrian hamsters the fate of lysosomal material in liver may be different or redistribution of 239 Pu occurs at a later time. (author)

  18. Operating characteristics of a partial-block randomized crossover bioequivalence study for dutasteride, a drug with a long half-life: investigation through simulation and comparison with final results.

    Science.gov (United States)

    Cai, Gengqian; Thiessen, Jake J; Baidoo, Charlotte A; Fossler, Michael J

    2010-10-01

    Studies to establish bioequivalence (BE) of a drug are important elements in support of drug applications. A typical BE study is conducted as a single dose, randomized, 2-period crossover design. For drugs with long half lives (≥ 48 hours) and evaluation of multiple BE objectives in 1 trial, this design may not be adequate. A parallel design may then be a more appropriate choice. However, parallel designs require increased sample size, which can become substantial. One option that is a compromise between the complete randomized block design and the parallel design is a partial-block crossover design. This approach came about during the development of a combination of dutasteride and tamsulosin. Previous experience with performing single-dose dutasteride studies suggested that 28 days of washout is needed between treatments because of its half-life of 7-9 days. Simulations were performed to assess the operating characteristics of this design using a previously developed PK model. Four scenarios were developed, and each scenario was simulated 500 times. The results showed that this design demonstrated acceptable consumer and producer risk. Partial-block crossover designs should be considered for studies when the half-life of the drug is long and there are more than 2 periods.

  19. Dopamine plasma clearance is increased in piglets compared to neonates during continuous dopamine infusion

    DEFF Research Database (Denmark)

    Rasmussen, Martin B; Gramsbergen, Jan Bert; Eriksen, Vibeke Ramsgaard

    2018-01-01

    pharmacokinetics. METHODS: Arterial blood samples were drawn from six neonates admitted to the neonatal intensive care unit of Copenhagen University Hospital and 20 newborn piglets during continuous dopamine infusion. Furthermore, to estimate the piglet plasma dopamine half-life, blood samples were drawn at 2.......5-minute intervals after the dopamine infusion was discontinued. The plasma dopamine content was analysed by high-performance liquid chromatography with electrochemical detection. RESULTS: The dopamine displayed first-order kinetics in piglets and had a half-life of 2.5 minutes, while the median plasma...

  20. Generalized correlation dimension - a way to analyze short time changes in non-linear dynamics of thermal plasma

    Czech Academy of Sciences Publication Activity Database

    Gruber, Jan

    2011-01-01

    Roč. 56, č. 2 (2011), s. 185-205 ISSN 0001-7043 Institutional research plan: CEZ:AV0Z20570509 Keywords : correlation dimension * time-embeddings * chaos Subject RIV: BL - Plasma and Gas Discharge Physics

  1. Generation of shock fronts in the interaction of the short pulses of intense laser light in supercritical plasma

    International Nuclear Information System (INIS)

    Lopez V, V.E.

    2004-01-01

    The plasma is the state of the matter but diffused in the nature. The sun and the stars big heaps of hot plasma can be considered. The external surface of the terrestrial atmosphere this recovered by a layer of plasma. All gassy discharge (lightning spark arch etc.) this related with the formation of plasma. This way, 99 percent of our environment this formed almost of plasma. It is denominated plasma to the ionized gas in the one which all or most of the atoms have lost one or several of the electrons that belonged him, becoming positive ions and free electrons. In the plasma certain physical characteristics exist as for their behavior like they are the collective movements the quasi neutrality, the Debye length, the uncertainty etc. All these behaviors make that the study of the plasma is complex. For this they exist technical of numeric simulation joined to the technological advance of big computers of more capacity and prosecution speed. The simulation techniques of particles are those where a numeric code is built based on a model or theory of a system that it is wanted to investigate. This way through the simulation the results are compared with those theoretical predictions based on an analytic model. The applications of the physics of the plasma are multiple however we focus ourselves in the interaction laser-plasma. Both finish decades of investigation in the interaction of lasers with plasma they have been carried out in laboratories of Europe, Japan, United States. This studies concern the propagation of intense light laser in dense plasma homogeneous, the radiation absorption in cold plasma and problems related with the generation of suprathermal electrons among others. Other areas of the physics of the plasma-laser interaction that it has been considerable attention is the broadly well-known field as parametric uncertainties induced instabilities by the light and that they include the dispersions for example stimulated Raman and Brillouin being able to

  2. Effects of short-term niacin treatment on plasma lipoprotein concentrations in African green monkeys (Chlorocebus aethiops)

    KAUST Repository

    Chauke, Chesa G.; Arieff, Zainunisha; Kaur, Mandeep; Seier, Jü rgen V.

    2014-01-01

    Niacin is the most effective drug available for raising levels of high-density lipoprotein (HDL) cholesterol. To evaluate its effects on plasma lipid concentrations, the authors administered a low dose of niacin to healthy, adult, female African

  3. Plasma concentrations of misonidazole

    Energy Technology Data Exchange (ETDEWEB)

    Notter, G; Rylander, U; Turesson, I

    1980-10-01

    The plasma concentrations of misonidazole doses between 0.6 and 2.0 g/m/sup 2/ were analyzed in respect to the variation within the same patient and between different patients. Peak plasma levels were observed after 2 hours. The mean plasma levels of misonidazole only at 3 hours were 23.8, 47.0 and 76.5 ..mu..g/ml after misonidazole doses of 0.6, 1.2 g/m/sup 2/, respectively. The half-life of misonidazole only was found to be 8.2 hours for women and 10.5 for men. Good linearity between plasma levels and drug doses was observed after administration of different single doses to the same patient within the dose range 0.6 to 2.0 g/m/sup 2/.

  4. Short and long time effects of low temperature Plasma Activated Media on 3D multicellular tumor spheroids

    Science.gov (United States)

    Judée, Florian; Fongia, Céline; Ducommun, Bernard; Yousfi, Mohammed; Lobjois, Valérie; Merbahi, Nofel

    2016-02-01

    This work investigates the regionalized antiproliferative effects of plasma-activated medium (PAM) on colon adenocarcinoma multicellular tumor spheroid (MCTS), a model that mimics 3D organization and regionalization of a microtumor region. PAM was generated by dielectric barrier plasma jet setup crossed by helium carrier gas. MCTS were transferred in PAM at various times after plasma exposure up to 48 hours and effect on MCTS growth and DNA damage were evaluated. We report the impact of plasma exposure duration and delay before transfer on MCTS growth and DNA damage. Local accumulation of DNA damage revealed by histone H2AX phosphorylation is observed on outermost layers and is dependent on plasma exposure. DNA damage is completely reverted by catalase addition indicating that H2O2 plays major role in observed genotoxic effect while growth inhibitory effect is maintained suggesting that it is due to others reactive species. SOD and D-mannitol scavengers also reduced DNA damage by 30% indicating that and OH* are involved in H2O2 formation. Finally, PAM is able to retain its cytotoxic and genotoxic activity upon storage at +4 °C or -80 °C. These results suggest that plasma activated media may be a promising new antitumor strategy for colorectal cancer tumors.

  5. Influence of antithyroid medication on effective half-life and uptake of {sup 131}I following radioiodine therapy; Einfluss thyreostatischer Medikation beim Morbus Basedow auf die Kinetik von 131-Iod waehrend einer Radiotherapie

    Energy Technology Data Exchange (ETDEWEB)

    Moka, D.; Voth, E.; Schicha, H. [Koeln Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin

    1997-12-01

    Aim of this study was to assess the influence of antithyroid drugs (ADT) on the kinetics of {sup 131}I. Therefore, 56 patients with Graves` disease and with shortened effective half-life of {sup 131}I were examined under stationary conditionary conditions. In 38 patients ATD was stopped three days after radioiodine therapy (RIT). The progress of the first RIT and of a second RIT, which still was necessary in 12 patients, was compared to 18 patients receiving ATD continuously. Values of effective half-life for {sup 131}I rose significantly from 3.4 to 5.7 days 2-3 days after stopping ATD. There was an increase of the {sup 131}I-uptake of a second RIT after stopping ATD from 29.0 to 38.4%. In contrast, {sup 131}I-uptake of a second RIT decreased significantly in patients receiving ATD continuously. Effective half-life and uptake of {sup 131}I were affected significantly by ATD. Interrupting ATD after RIT is useful to improve an apparantly insufficient RIT in thyrotoxic patients receiving ATD. (orig.) [Deutsch] Ziel dieser Studie war es, beim M. Basedow die Kinetik von {sup 131}I unter dem Einfluss thyreostatischer Medikation (tM) zu untersuchen. Dazu wurden die 56 Patienten mit immunogener Hyperthyreose M. Basedow (MB) und mit einem erhoehten `turn over` von {sup 131}I unter tM untersucht. Bei 38 Patienten wurde die tM am 3. Tag nach RITh abgesetzt. Der Verlauf der 1. RITh bzw. einer Nachtherapie wurde mit 18 Patienten unter fortlaufender tM verglichen. 2-3 Tage nach Absetzen der tM stieg die effektive Halbwertzeit (HWZ{sub eff.}) von {sup 131}I signifikant von 3,4 auf 5,7 Tage und der {sup 131}I-Uptake bei der Nachtherapie von 29,0 auf 38,4% an, waehrend er unter fortlaufender tM signifikant abfiel. Beide Effekte zeigen, dass tM die {sup 131}I-Kinetik der Schilddruese sehr schnell beeinflussen kann. Gezieltes Absetzen der tM eignet sich deshalb, um bei ausgewaehlten Patienten eine primaer unzureichende RITh noch waehrend des stationaeren Aufenthaltes zu steuern und

  6. Half-life Measurements of {sup 6}He, {sup 16}N, {sup 19}O, {sup 20}F, {sup 28}Al, {sup 77m}Se and {sup 110}Ag

    Energy Technology Data Exchange (ETDEWEB)

    Konijn, J; Malmskog, S

    1962-06-15

    The half-life of different isotopes, activated by neutrons in the reactor R2-0 by means of a pneumatic rabbit, have been measured with a pulse height analyzer working in its multiscale mode of operation. A Nal(Tl)-scintillation spectrometer was used as detector. Least squares analysis calculated by the Mercury computer were performed for each measurement. The following weighted mean values of the half-lives are obtained {sup 6}He: 0.862 {+-} 0.017 sec.; {sup 16}N: 7.31 {+-} 0.04 sec.; {sup 19}O: 29.1 {+-} 0.3 sec.; {sup 20}F: 11.56 {+-} 0.05 sec.; {sup 28}Al: 2.31 {+-} 0.01 min.; {sup 77m}Se: 18.83 - 0.04 sec.; and {sup 110}Ag: 24.42 {+-} 0.14 sec.

  7. Optimum electron temperature and density for short-wavelength plasma-lasing from nickel-like ions

    International Nuclear Information System (INIS)

    Masoudnia, Leili; Bleiner, Davide

    2014-01-01

    Soft X-ray lasing across a Ni-like plasma gain-medium requires optimum electron temperature and density for attaining to the Ni-like ion stage and for population inversion in the 3d 9 4d 1 (J=0)→3d 9 4p 1 (J=1) laser transition. Various scaling laws, function of operating parameters, were compared with respect to their predictions for optimum temperatures and densities. It is shown that the widely adopted local thermodynamic equilibrium (LTE) model underestimates the optimum plasma-lasing conditions. On the other hand, non-LTE models, especially when complemented with dielectronic recombination, provided accurate prediction of the optimum plasma-lasing conditions. It is further shown that, for targets with Z equal or greater than the rare-earth elements (e.g. Sm), the optimum electron density for plasma-lasing is not accessible for pump-pulses at λ=1ω=1μm. This observation explains a fundamental difficulty in saturating the wavelength of plasma-based X-ray lasers below 6.8 nm, unless using 2ω pumping

  8. X-ray spectroscopic technique for energetic electron transport studies in short-pulse laser/plasma interactions

    Energy Technology Data Exchange (ETDEWEB)

    Tutt, T.E.

    1994-12-01

    When a solid target is irradiated by a laser beam, the material is locally heated to a high temperature and a plasma forms. The interaction of the laser with plasma can produce energetic electrons. By observing the behavior of these {open_quotes}hot{close_quotes} electrons, we hope to obtain a better understanding of Laser/Plasma Interactions. In this work we employ a layered-fluorescer technique to study the transport, and therefore the energetics, of the electrons. The plasma forms on a thin foil of metallic Pd which is bonded to thin layer of metallic Sn. Electrons formed from the plasma penetrate first the Pd and then the Sn. In both layers the energetic electrons promote inner (K) shell ionization of the metallic atoms which leads to the emission of characteristic K{sub {alpha}} x-rays of the fluorescers. By recording the x-ray spectrum emitted by the two foils, we can estimate the energy-dependent range of the electrons and their numbers.

  9. Treatment of short-lived radioactive wastes

    International Nuclear Information System (INIS)

    Yamaguchi, Chiri

    1976-01-01

    Recently short life nuclides have come to be utilized increasingly as diagnostic radioisotopes, and Tc-99m (half-life; 6.05 hours) and Ga-67 (half-life 7.79 hours) are replacing the most nuclides fomerly used in vivo test. Such development of radioactive products inevitably causes the rapid increase of their wastes. At present, the radioactive wastes produced by hospitals and university laboratories in Japan are collected by the Japan Radioisotope Association, and treated by the Japan Atomic Energy Research Institute. These wastes are divided into combustibles and incombustibles to store in the store house in the Japan Atomic Energy Research Institute. The present law in Japan contains the contradiction which treats the matter with one several millionth of radioactivity after decay same as the original radioactive matter. Thus solid must be stored permanently, while gas and liquid can be discharged after dilution. (Kobatake, H.)

  10. Short torch design for direct liquid sample introduction using conventional and micro-nebulizers for plasma spectrometry

    Science.gov (United States)

    Montaser, Akbar [Potomac, MD; Westphal, Craig S [Landenberg, PA; Kahen, Kaveh [Montgomery Village, MD; Rutkowski, William F [Arlington, VA

    2008-01-08

    An apparatus and method for providing direct liquid sample introduction using a nebulizer are provided. The apparatus and method include a short torch having an inner tube and an outer tube, and an elongated adapter having a cavity for receiving the nebulizer and positioning a nozzle tip of the nebulizer a predetermined distance from a tip of the outer tube of the short torch. The predetermined distance is preferably about 2-5 mm.

  11. Hosing, sausaging, filamentation and side-scatter of a high-intensity short-pulse laser in an under-dense plasma

    International Nuclear Information System (INIS)

    Najmudin, Z.; Krushelnick, K.; Clark, E.L.; Salvati, M.; Santala, M.I.K.; Tatarakis, M.; Dangor, A.E.

    2000-01-01

    Previous studies of high-intensity short-pulse laser beams propagating in under-dense plasma have relied on spectrally integrated Thomson scattering images. Though interesting, many significant features of the interaction cannot be diagnosed by this method. We report on shadow-graphy and spectrally resolved Thomson scattering of such an interaction. These images reveal many processes previously predicted but unseen, such as the Raman side-scatter and filamentation instabilities. Also the interaction is shown to clearly demonstrate many propagation instabilities such as 'sausaging' and 'hosing' for the first time. (authors)

  12. Generation of shock fronts in the interaction of short pulses of intense laser light in supercritical plasma

    International Nuclear Information System (INIS)

    Lopez V, V.E.; Ondarza R, R.

    2004-01-01

    The investigation of the laser interaction with plasma has been carried out mainly in laboratories of Europe, Japan and United States during the last decades. This studies concern the propagation of intense light laser in a non homogeneous plasma, the radiation absorption and the generation of suprathermal electrons, among others. Numerical simulations made by Denavit, for radiation pulses for up of 10 20 W/cm 2 on solid targets, have allowed to observe the generation of ionic crash fronts with high propagation speeds. In this work it is expanded the study of this effect through algorithms of particles simulation. (Author)

  13. Short-term increase of plasma free fatty acids does not interfere with intrinsic mitochondrial function in healthy young men

    NARCIS (Netherlands)

    Brands, Myrte; Hoeks, Joris; Sauerwein, Hans P.; Ackermans, Mariette T.; Ouwens, Margriet; Lammers, Nicolette M.; van der Plas, Mart N.; Schrauwen, Patrick; Groen, Albert K.; Serlie, Mireille J.

    2011-01-01

    Free fatty acid (FFA)- and obesity-induced insulin resistance has been associated with disturbed mitochondrial function. Elevated plasma FFA can impair insulin-induced increase of adenosine triphosphate synthesis and downregulate the expression of genes important in the biogenesis of mitochondria in

  14. Plasma HIV-1 Tropism and the Risk of Short-Term Clinical Progression to AIDS or Death

    DEFF Research Database (Denmark)

    Casadellà, Maria; Cozzi-Lepri, Alessandro; Phillips, Andrew

    2017-01-01

    OBJECTIVE: To investigate if plasma HIV-1 tropism testing could identify subjects at higher risk for clinical progression and death in routine clinical management. DESIGN: Nested case-control study within the EuroSIDA cohort. METHODS: Cases were subjects with AIDS or who died from any cause...

  15. The plasma and cerebrospinal fluid pharmacokinetics of erlotinib and its active metabolite (OSI-420) after intravenous administration of erlotinib in non-human primates.

    Science.gov (United States)

    Meany, Holly J; Fox, Elizabeth; McCully, Cynthia; Tucker, Chris; Balis, Frank M

    2008-08-01

    Erlotinib hydrochloride is a small molecule inhibitor of epidermal growth factor receptor (EGFR). EGFR is over-expressed in primary brain tumors and solid tumors that metastasize to the central nervous system. We evaluated the plasma and cerebrospinal fluid (CSF) pharmacokinetics of erlotinib and its active metabolite OSI-420 after an intravenous (IV) dose in a non-human primate model. Erlotinib was administered as a 1 h IV infusion to four adult rhesus monkeys. Serial blood and CSF samples were drawn over 48 h and erlotinib and OSI-420 were quantified with an HPLC/tandem mass spectroscopic assay. Pharmacokinetic parameters were estimated using non-compartmental and compartmental methods. CSF penetration was calculated from the AUC(CSF):AUC(plasma). Erlotinib disappearance from plasma after a short IV infusion was biexponential with a mean terminal half-life of 5.2 h and a mean clearance of 128 ml/min per m(2). OSI-420 exposure (AUC) in plasma was 30% (range 12-59%) of erlotinib, and OSI-420 clearance was more than 5-fold higher than erlotinib. Erlotinib and OSI-420 were detectable in CSF. The CSF penetration (AUC(CSF):AUC(plasma)) of erlotinib and OSI-420 was OSI-420 are measurable in CSF after an IV dose. The drug exposure (AUC) in the CSF is limited relative to total plasma concentrations but is substantial relative the free drug exposure in plasma.

  16. Theoretical Study of the Endogenous Production of N-13 in 115 kJ Plasma Focus Device Using Methane Gas

    Science.gov (United States)

    Faghih Haghani, Saeedeh; Sadighzadeh, A.; Talaei, A.; Zaeem, A. A.; Sadat Kiai, S. M.; Heydarnia, A.; Damideh, V.

    2013-08-01

    Mather type plasma focus device with the bank energy of 115 kJ (40 kV, 144μF) was studied for induced activity of N-13; a short-lived radioisotope β+ emitter with 511 keV of gamma rays and has a half-life of t1/2 = 9.93 min through 12C (d, n)13N nuclear reaction. N-13 radioisotope is used in Positron Emission Tomography (PET) for imaging and treatment. In this paper endogenous production of 13N is considered. It is shown by adding 3-4 % CH4 to the chamber, the induced activity of N-13 has increased about 4 %. Our study is representative of producing 106 - 109 Bq induced activity of this SLR in IR-MPF-100 device.

  17. Plasma Growth Hormone and Prolactin Levels in Healthy Sedentary Young Men after Short-Term Endurance Training under Hot Environment

    Directory of Open Access Journals (Sweden)

    İbrahim Cicioglu

    2013-09-01

    Full Text Available Pituitary hormones play an important role energy expenditure and body temperature regulation during exercise. The aim of the stu¬dy was to investigate the effect of two different endurance training in ambient temperature (30.76 ± 1.71oC and 57.92 ± 5.80% r.h. on plasma growth hormone (GH and prolactin (PRL levels in non-trained healthy subjects. Twenty-four untrained healthy men participated in an 8-wk progressive two different endurance-training program. Subjects were divided into two groups: an in¬ter¬val running group (IR, and continuous running group (CR. Both groups were performed 3 days/wk. Growth hormone, PRL and VO2max levels were assessed at the beginning and the end of the training period. Body temperature (TB was also measured at the be¬ginning and immediately after each training. The exercise type affected plasma PRL (8.52 vs. 6.50 ng/ml IR and CT groups, P 0.38. Plasma GH level at the end of training pro¬gram increased from 0.42 to 1.48 ng/ml and 0.58 to 0.67 ng/ml for IR and CR groups. Expectedly, both training types increased TB, at a greater rate for IR group than CR group. In conclusion, an 8-wk regular exercise result in an increase in plasma PRL level, with¬out altering plasma GH level, which accompanied by elevated body temperature, regardless of the individual’s sporting rou¬ti¬ne. These suggest that untrained individuals could benefit from a regular exercise program as much as those doing the routine sport.

  18. Experimental characterization of a strongly coupled solid density plasma generated in a short-pulse laser target interaction

    International Nuclear Information System (INIS)

    Gregori, G.; Hansen, S.B.; Key, M.H.; King, J.; Mackinnon, A.J.; Park, H.; Patel, P.K.; Shepard, R.; Snavely, R.A.; Wilks, S.C.; Glenzer, S.H.

    2005-01-01

    We have measured high resolution copper Kα spectra from a picosecond high intensity laser produced plasma. By fitting the shape of the experimental spectra with a self-consistent-field model which includes all the relevant line shifts from multiply ionized atoms, we are able to infer time and spatially averaged electron temperatures (T e ) and ionization state (Z) in the foil. Our results show increasing values for T e and Z when the overall mass of the target is reduced. In particular, we measure temperatures in excess of 200 eV with Z ∼ 13-14. For these conditions the ion-ion coupling constant is Λ ii ∼ 8-9, thus suggesting the achievement of a strongly coupled plasma regime

  19. Analysis of the M-shell spectra emitted by a short-pulse laser-created tantalum plasma

    Science.gov (United States)

    Busquet; Jiang; Coinsertion Markte CY; Kieffer; Klapisch; Bar-Shalom; Bauche-Arnoult; Bachelier

    2000-01-01

    The spectrum of tantalum emitted by a subpicosecond laser-created plasma, was recorded in the regions of the 3d-5f, 3d-4f, and 3d-4p transitions. The main difference with a nanosecond laser-created plasma spectrum is a broad understructure appearing under the 3d-5f transitions. An interpretation of this feature as a density effect is proposed. The supertransition array model is used for interpreting the spectrum, assuming local thermodynamic equilibrium (LTE) at some effective temperature. An interpretation of the 3d-4f spectrum using the more detailed unresolved transition array formalism, which does not assume LTE, is also proposed. Fitted contributions of the different ionic species differ slightly from the LTE-predicted values.

  20. Experimental characterization of a strongly coupled solid density plasma generated in a short-pulse laser target interaction

    Energy Technology Data Exchange (ETDEWEB)

    Gregori, G; Hansen, S B; Key, M H; King, J; Mackinnon, A J; Park, H; Patel, P K; Shepard, R; Snavely, R A; Wilks, S C; Glenzer, S H

    2005-03-17

    We have measured high resolution copper K{alpha} spectra from a picosecond high intensity laser produced plasma. By fitting the shape of the experimental spectra with a self-consistent-field model which includes all the relevant line shifts from multiply ionized atoms, we are able to infer time and spatially averaged electron temperatures (T{sub e}) and ionization state (Z) in the foil. Our results show increasing values for T{sub e} and Z when the overall mass of the target is reduced. In particular, we measure temperatures in excess of 200 eV with Z {approx} 13-14. For these conditions the ion-ion coupling constant is {Lambda}{sub ii} {approx} 8-9, thus suggesting the achievement of a strongly coupled plasma regime.

  1. X-ray spectroscopy of a thin foil plasma produced by a short-pulse high-intensity laser

    International Nuclear Information System (INIS)

    Audebert, P.; Nagels, V.; Geindre, J.P.; Dorchies, F.; Peyrusse, O.; Gary, S.; Girard, F.; Shepherd, R.; Gauthier, J.C.; Chenais-Popovics, C.

    2003-01-01

    High density and temperature plasmas have been generated by irradiating thin foils of various elements with a high-energy subpicosecond laser pulse. The X-ray emission duration was studied by time-resolved X-ray spectroscopy. Frequency domain interferometry provided a measurement of the hydrodynamic expansion of the back of the foil as a function of time. The effect of longitudinal temperature gradients, i.e., gradients perpendicular to the surface, were decreased using very thin foil targets. Additionally, radial gradients effects, i.e., gradients parallel to the surface, were limited by using a 50 μm pinhole on target. The Al, Se and Sm spectra, recorded in the range 7.7-8 Angst. using a conical crystal spectrometer coupled to an 800 fs resolution streak camera, lasted a few picoseconds. Sm spectra showed no spectral features in this wavelength range, providing a spectrally homogeneous backlighter for future experiments. The main features of the experimental time-resolved spectra have been well reproduced with one-dimensional hydrodynamic simulations of the free expansion of a plasma heated at a given initial temperature obtained from the expansion velocity of the rear critical surface of the plasma

  2. Influence of antithyroid medication on effective half-life and uptake of {sup 131} I following radioiodine therapy; Einflussfon thyreostatischer Medikation auf die effektive Halbwertzeit und den Uptake von {sup 131}Iod waehrend einer Radioiodtherapie

    Energy Technology Data Exchange (ETDEWEB)

    Moka, D. [Koeln Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Voth, E. [Koeln Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Schicha, H. [Koeln Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin

    1997-04-01

    Aim: A radioiodine therapy (RIT) in thyrotoxic patients receiving antithyroid drugs (ATD) leads in comparison to nonpretreated patients either to higher therapeutic doses or to higher treatment failure rates. Aim of this study was to optimize the effect of RIT in patients pretreated with ATD. Methods: Therefore, the influence of ATD was assessed in 109 patients with shortened effective half-life of {sup 131}I. RIT was performed under stationary conditions. Radioiodine activity of the thyroid gland was stopped three days after RIT. The patients antithyroid medication was stopped three days after RIT. The progress of the first RIT and of a second radioiodine application, which still was necessary in 29 patients, was compared to 32 patients receiving ATD, continuously. Results: Values of effective half-life for {sup 131}I rose significantly from 3.2{+-}0.2 to 5.7{+-}0.2 days (Graves` disease: 3.4 to 5.7 days; toxic goiters` disease: Multifocal autonomy 3.2 to 6.2 days; unifocal autonomy 2.5 auf 5.0 days) 2-3 days after stopping ATD. There was an increase of the {sup 131}I-uptake of a second RIT decreased significantly in patients receiving ATD, continuously. Conclusion: Effective half-life and uptake of {sup 131}I was affected significantly by ATD. The stop taking of ATD after RIT is useful to improve an apparent insufficient RIT in thyrotoxic patients receiving ATD. (orig.) [Deutsch] Ziel: Eine Radioiodtherapie (RITh) unter laufender thyreostatischer Medikation bei hyperthyreoten Patienten fuehrt im Vergleich zu unbehandelten Patienten entweder zu hoeheren Therapiedosen oder zu einem hoeheren Prozentsatz von Therapieversagern. Ziel dieser Studie war es, die RITh unter thyreostatischer Medikation zu optimieren. Methoden: Der Einfluss der thyreostatischen Medikation wurde bei 109 Patienten mit verkuerzter thyreoidaler Halbwertzeit von {sup 131}I untersucht. Bei 77 Patienten wurde die thyreostatische Medikation am 3. Tag nach RITh abgesetzt. Der Verlauf der RITh bzw

  3. ⁸⁹Zr-Labeled Versus ¹²⁴I-Labeled αHER2 Fab with Optimized Plasma Half-Life for High-Contrast Tumor Imaging In Vivo.

    Science.gov (United States)

    Mendler, Claudia T; Gehring, Torben; Wester, Hans-Jürgen; Schwaiger, Markus; Skerra, Arne

    2015-07-01

    Immuno-PET imaging of the tumor antigen HER2/neu allows for the noninvasive detection and monitoring of oncogene expression; such detection and monitoring are of prognostic value in patients with breast cancer. Compared with the full-size antibody trastuzumab, smaller protein tracers with more rapid blood clearance permit higher imaging contrast at earlier time points. Antigen-binding fragments (Fabs) of antibodies with moderately prolonged circulation achieved through the genetic fusion with a long, conformationally disordered chain of the natural amino acids Pro, Ala, and Ser (PASylation)-a biologic alternative to chemical conjugation with polyethylene glycol, PEG-offer a promising tracer format with improved pharmacokinetics for in vivo imaging. Recently, the transition metal radionuclide (89)Zr has attracted increasing interest for immuno-PET studies, complementing the conventional halogen radionuclide (124)I. To allow direct comparison of these 2 radioactive labels for the same protein tracer, the recombinant αHER2 Fab fused with 200 Pro, Ala, and Ser (PAS200) residues was either conjugated with (124)I via an iodination reagent or coupled with deferoxamine (Df) and complexed with (89)Zr. After confirmation of the stability of both radioconjugates and quality control in vitro, immuno-PET and biodistribution studies were performed with CD1-Foxn1(nu) mice bearing HER2-positive human tumor xenografts. (89)Zr⋅Df-Fab-PAS200 and (124)I-Fab-PAS200 showed specific tumor uptake of 11 and 2.3 percentage injected dose per gram 24 h after injection, respectively; both led to high tumor-to-blood (3.6 and 4.4, respectively) and tumor-to-muscle (20 and 43, respectively) ratios. With regard to off-target accumulation, overt (124)I activity was seen in the thyroid, as expected, whereas high kidney uptake was evident for (89)Zr; the latter was probably due to glomerular filtration and reabsorption of the protein tracer in proximal tubular cells. Both (89)Zr- and (124)I-labeled versions of αHER2 Fab-PAS200 allowed PET tumor imaging with high contrast. With its residualizing radiometal, the tracer (89)Zr⋅Df-Fab-PAS200 showed better in vivo stability and higher tumor uptake. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  4. Backscattering of gyrotron radiation and short-wavelength turbulence during electron cyclotron resonance plasma heating in the L-2M stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Batanov, G. M.; Borzosekov, V. D., E-mail: tinborz@gmail.com; Kovrizhnykh, L. M.; Kolik, L. V.; Konchekov, E. M.; Malakhov, D. V.; Petrov, A. E.; Sarksyan, K. A.; Skvortsova, N. N.; Stepakhin, V. D.; Kharchev, N. K. [Russian Academy of Sciences, Prokhorov General Physics Institute (Russian Federation)

    2013-06-15

    Backscattering of gyrotron radiation ({theta} = {pi}) by short-wavelength density fluctuations (k{sub Up-Tack} = 30 cm{sup -1}) in the plasma of the L-2M stellarator was studied under conditions of electron cyclotron resonance (ECR) plasma heating at the second harmonic of the electron gyrofrequency (75 GHz). The scattering of the O-wave emerging due to the splitting of the linearly polarized gyrotron radiation into the X- and O-waves was analyzed. The signal obtained after homodyne detection of scattered radiation is a result of interference of the reference signal, the quasi-steady component, and the fast oscillating component. The coefficients of reflection of the quasi-steady component, R{sub =}{sup 2}(Y), and fast oscillating component, R{sub {approx}}{sup 2}(Y), of scattered radiation are estimated. The growth of the R{sub {approx}}{sup 2}(Y) coefficient from 3.7 Multiplication-Sign 10{sup -4} to 5.2 Multiplication-Sign 10{sup -4} with increasing ECR heating power from 190 to 430 kW is found to correlate with the decrease in the energy lifetime from 1.9 to 1.46 ms. The relative density of short-wavelength fluctuations is estimated to be Left-Pointing-Angle-Bracket n{sub {approx}}{sup 2} Right-Pointing-Angle-Bracket / Left-Pointing-Angle-Bracket n{sub e}{sup 2} Right-Pointing-Angle-Bracket = 3 Multiplication-Sign 10{sup -7}. It is shown that the frequencies of short-wavelength fluctuations are in the range 10-150 kHz. The recorded short-wavelength fluctuations can be interpreted as structural turbulence, the energy of which comprises {approx}10% of the total fluctuations energy. Simulations of transport processes show that neoclassical heat fluxes are much smaller than anomalous ones. It is suggested that short-wavelength turbulence plays a decisive role in the anomalous heat transport.

  5. Metabonomics Analysis of Plasma Reveals the Lactate to Cholesterol Ratio as an Independent Prognostic Factor of Short-Term Mortality in Acute Heart Failure

    Science.gov (United States)

    Desmoulin, Franck; Galinier, Michel; Trouillet, Charlotte; Berry, Matthieu; Delmas, Clément; Turkieh, Annie; Massabuau, Pierre; Taegtmeyer, Heinrich; Smih, Fatima; Rouet, Philippe

    2013-01-01

    Objective Mortality in heart failure (AHF) remains high, especially during the first days of hospitalization. New prognostic biomarkers may help to optimize treatment. The aim of the study was to determine metabolites that have a high prognostic value. Methods We conducted a prospective study on a training cohort of AHF patients (n = 126) admitted in the cardiac intensive care unit and assessed survival at 30 days. Venous plasmas collected at admission were used for 1H NMR – based metabonomics analysis. Differences between plasma metabolite profiles allow determination of discriminating metabolites. A cohort of AHF patients was subsequently constituted (n = 74) to validate the findings. Results Lactate and cholesterol were the major discriminating metabolites predicting 30-day mortality. Mortality was increased in patients with high lactate and low total cholesterol concentrations at admission. Accuracies of lactate, cholesterol concentration and lactate to cholesterol (Lact/Chol) ratio to predict 30-day mortality were evaluated using ROC analysis. The Lact/Chol ratio provided the best accuracy with an AUC of 0.82 (P ratio ≥ 0.4 (cutoff value with 82% sensitivity and 64% specificity) were significant independent predictors of 30-day mortality with hazard ratios (HR) of 1.11, 4.77 and 3.59, respectively. In CS patients, the HR of 30-day mortality risk for plasma Lact/Chol ratio ≥ 0.4 was 3.26 compared to a Lact/Chol ratio of ratio for 30-day mortality outcome was confirmed with the independent validation cohort. Conclusion This study identifies the plasma Lact/Chol ratio as a useful objective and simple parameter to evaluate short term prognostic and could be integrated into quantitative guidance for decision making in heart failure care. PMID:23573279

  6. Observation of scattered light between omega/2 and 3/2 omega in short wavelength laser produced plasmas

    International Nuclear Information System (INIS)

    Goldman, L.M.; Seka, W.; Tanaka, K.; Simon, A.; Short, R.

    1984-01-01

    Extensive measurements have been carried out on scattered radiation in the spectral region between omega/2 and 3/2 omega from plasmas produced by 351 nm lasers. The relative intensities of the continuum radiation relative to the line features at omega/2 and 3/2 omega will be shown. A new spectral feature has been observed between 3/2 omega and omega which may be interpreted as an upscattered component produced by ordinary Raman scattering. The overall experimental evidence for ordinary Raman scattering vs stimulated Raman scattering will be discussed

  7. Effects of short-term niacin treatment on plasma lipoprotein concentrations in African green monkeys (Chlorocebus aethiops).

    Science.gov (United States)

    Chauke, Chesa G; Arieff, Zainunisha; Kaur, Mandeep; Seier, Jurgen V

    2014-02-01

    Niacin is the most effective drug available for raising levels of high-density lipoprotein (HDL) cholesterol. To evaluate its effects on plasma lipid concentrations, the authors administered a low dose of niacin to healthy, adult, female African green monkeys for 3 months. In the treated monkeys, low-density lipoprotein cholesterol concentrations decreased by 43% from baseline, whereas concentrations of HDL cholesterol and apolipoprotein A-I increased by 49% and 34%, respectively. The results suggest that in this primate model, a low dose of niacin can effectively increase concentrations of HDL cholesterol.

  8. Effects of short-term niacin treatment on plasma lipoprotein concentrations in African green monkeys (Chlorocebus aethiops)

    KAUST Repository

    Chauke, Chesa G.

    2014-01-22

    Niacin is the most effective drug available for raising levels of high-density lipoprotein (HDL) cholesterol. To evaluate its effects on plasma lipid concentrations, the authors administered a low dose of niacin to healthy, adult, female African green monkeys for 3 months. In the treated monkeys, low-density lipoprotein cholesterol concentrations decreased by 43% from baseline, whereas concentrations of HDL cholesterol and apolipoprotein A-I increased by 49% and 34%, respectively. The results suggest that in this primate model, a low dose of niacin can effectively increase concentrations of HDL cholesterol.©2014 Nature America, Inc. All rights reserved.

  9. Decay properties of short-lived mass-separated fission products

    International Nuclear Information System (INIS)

    Lund, E.

    1977-01-01

    The present work describes determinations of total β-decay energies and studies of delayed neutron emission including the identification and half-life determinations of delayed neutron precursors and the measurement of neutron spectra. It also includes a short review of the OSIRIS on-line isotope separator facility. (Auth.)

  10. Development of the k0-based cyclic neutron activation analysis for short-lived radionuclides

    NARCIS (Netherlands)

    Dung, H.M.; Blaauw, M.; Beasley, D.; Freitas, M.D.C.

    2011-01-01

    The k0-based cyclic neutron activation analysis (k0-CNAA) technique has been studied to explore the applicability at the Portuguese research reactor (RPI). In particular, for the determination of elements which form short-lived radionuclides, particularly fluorine (20F, 11.16 s half-life) and

  11. An overview of the ecological half-life of the 137Cs radioisotope and a determination of radioactivity levels in sediment samples after Chernobyl in the Eastern Black Sea, Turkey

    Science.gov (United States)

    Baltas, Hasan; Sirin, Murat; Dalgic, Goktug; Cevik, Ugur

    2018-01-01

    A study which determined the activity concentration of 137Cs in sediments contaminated by effluents from the Chernobyl accident which had collected along the coast of the Eastern Black Sea region in Turkey was carried out in 1993. Marine sediment samples were collected in 2015 from the same fifteen sampling points, and the activity concentrations of 226Ra, 232Th, 40K and 137Cs were determined for the sediment samples. The activity concentrations ranged from 10.94-25.95, 12.14-33.05, 265.74-459.89 and 2.08-37.45 Bq kg- 1 for 226Ra, 232Th, 40K and 137Cs respectively. The results showed that there was a steep decline in 137Cs within the sediment at most of the sampling sites from the Eastern Black Sea region during the 22-year period, except for two sites at which the measured levels were much higher. This may be the result of the combined effects of radioactive contaminant entry into this area from rivers, environmental changes and nuclear testing between 1993 and 2015. Furthermore, the ecological half-life (EHL) of the 137Cs radionuclide was estimated for the sediment samples, and radiological hazard parameters such as the absorbed dose rate in air (D), the annual effective dose equivalent (AEDE) and the excess lifetime cancer risk (ELCR) were calculated and compared with the international recommended values. It was shown that these sediments do not present any significant health risk for humans in this area.

  12. Investigation of temperature effect on half-life periods of long-lived isomer sup 1 sup 8 sup 0 sup m Hf and sup 8 sup 7 sup m Sr

    CERN Document Server

    Alpatov, V G; Davydov, A V; Isaev, Y N; Kartashov, G R; Korotkov, M M; Samojlov, V M

    2001-01-01

    The experiments on measuring the half-life periods of the sup 1 sup 8 sup 0 sup m Hf and sup 8 sup 7 sup m Sr long-lived isomers at the room temperature and at 77 K with application of the HfO sub 2 , Sr(NO sub 3) sub 2 and SrCO sub 3 massive samples are described. The isomer states of the corresponding nuclei were formed by the samples irradiation through neutrons from the Pu-Be source. According to the Vysotski theory and other authors the surrounding of the gamma-active nuclei by a large number of the same nuclei in the basic state should lead to the T sub 1 sub / sub 2 growth due to distortion of the zero electromagnetic vacuum oscillations near the nuclear energy level value. Decrease in the sample temperature leads to the narrowing of the gamma-lines, especially for the Moessbauer low-energy transitions, which increases the resonance effect on the zero oscillations spectrum. Increase in the T sub 1 sub / sub 2 by 2.99 +- 0.87% was observed by cooling the sup 1 sup 8 sup 0 sup m Hf isomer sample, in the ...

  13. Short-course TLR9 Agonist Treatment Impacts Innate Immunity and Plasma Viremia in Individuals with HIV infection

    DEFF Research Database (Denmark)

    Vibholm, Line; Schleimann, Mariane H; Højen, Jesper F

    2017-01-01

    Background.: Treatment with latency reversing agents (LRAs) enhances human immunodeficiency virus type 1 (HIV-1) transcription in vivo but leads to only modest reductions in the size of the reservoir, possibly due to insufficient immune-mediated elimination of infected cells. We hypothesized...... that a single drug molecule-a novel Toll-like receptor 9 (TLR9) agonist, MGN1703-could function as an enhancer of innate immunity and an LRA in vivo. Methods.: We conducted a single-arm, open-label study in which 15 virologically suppressed HIV-1-infected individuals on antiretroviral therapy received 60 mg MGN.......: In accordance with the cell type-specific expression of TLR9, MGN1703 treatment led to pronounced activation of plasmacytoid dendritic cells and substantial increases in plasma interferon-α2 levels (P

  14. Acceleration of a solid-density plasma projectile to ultrahigh velocities by a short-pulse ultraviolet laser

    Energy Technology Data Exchange (ETDEWEB)

    Badziak, J.; Jablonski, S. [Institute of Plasma Physics and Laser Microfusion, Euratom Association, 01-497 Warsaw (Poland)

    2011-08-15

    It is shown by means of particle-in-cell simulations that a high-fluence ({>=}1 GJ/cm{sup 2}) solid-density plasma projectile can be accelerated up to sub-relativistic velocities by radiation pressure of an ultraviolet (UV) picosecond laser pulse of moderate values of dimensionless laser amplitude a{sub 0}{approx}10. The efficiency of acceleration by the UV laser is significantly higher than in the case of long-wavelength ({lambda} {approx} 1 {mu}m) driver of a comparable value of a{sub 0}, and the motion of the projectile is fairly well described by the ''Light Sail'' acceleration model.

  15. Activation analysis with neutron generators using short-lived radionuclides

    International Nuclear Information System (INIS)

    Salma, I.

    1993-01-01

    The short half-life involves a number of important differences in production, transportation and measurement of radionuclides, and in counting statistics as compared with those in traditional activation analysis. Experiments were performed to investigate the analytical possibilities and prospective utilization of short-lived radionuclides produced by 14-MeV neutron irradiation. A rapid pneumatic transfer system for use with neutron generators was installed and applied for detecting radionuclides with a half-life from 300 ms to 30 s. The transport time for samples with a total mass of 1-4 g is between 130 and 160 ms for pressurized air of 0.1-0.4 MPa. 11 elements were studied by the conventional activation method using both a typical pneumatic transport system (run time 3 s) and the fast pneumatic transport facility. The effect of the cyclic activation technique on the elemental sensitivities was also investigated. (orig.)

  16. Time-frequency analysis of fusion plasma signals beyond the short-time Fourier transform paradigm: An overview

    International Nuclear Information System (INIS)

    Bizarro, Joao P.S.; Figueiredo, Antonio C.A.

    2008-01-01

    Performing a time-frequency (t-f) analysis on actual magnetic pick-up coil data from the JET tokamak, a comparison is presented between the spectrogram and the Wigner and Choi-Williams distributions. Whereas the former, which stems from the short-time Fourier transform and has been the work-horse for t-f signal processing, implies an unavoidable trade-off between time and frequency resolutions, the latter two belong to a later generation of distributions that yield better, if not optimal joint t-f localization. Topics addressed include signal representation in the t-f plane, frequency identification and evolution, instantaneous-frequency estimation, and amplitude tracking

  17. Relativistic motion of charged particles in the interaction of short pulses of intense laser light with plasma

    International Nuclear Information System (INIS)

    Gomez R, F.

    2004-01-01

    the electrons in the plasma. These oscillations, calls of Langmuir, its are produced by the present electric field in the electrically neuter plasma when it is produced any deviation of the space distribution of the electrons takes place regarding that of the equilibrium. An analytical theory for the case of a particle in a plasma, which decreases to the one described in the chapter 4 is studied. It will see that in a dense plasma the movement of the electrons produces strong interactions, which modify the dynamics of the electron and the propagation of the pulse. These effects will be analyzed by means of simulations in which a single particle intervenes and where the space-charge effects will be represented by means of a vectorial potential. In this calculation the effects of the movement of the electron on the propagation of the laser its will be rejected. Our results will be compare with those reported by Bardsley et al. and the excellent approaches obtained will be shown. To carry out the analytical compute in the calculations, atomic units (u a) are introduced, which are more appropriate for this type of study. For the interpretation of the numerical results it will be convenient to carry out certain analytical calculations. Diagrams of trajectory where the electron is initially in repose, and where the maximum amplitude of the electric field will be of 100 u a (5,14 x 10 11 V/cm), corresponding to an intensity of pulse of 3,5 x 10 20 W/cm 2 and to an optical frequency of ω = 0,18 u a, of a KrF laser will be present. The final part will dedicate it to the presentation and interpretation of our results, as well as the perspectives and research lines opened up around the studied problem. In the last part of this work its put on all the bibliographical references that have been consulted for the realization of this work. (Author)

  18. Environmental Metabolic Footprinting (EMF) vs. half-life: a new and integrative proxy for the discrimination between control and pesticides exposed sediments in order to further characterise pesticides' environmental impact.

    Science.gov (United States)

    Salvia, Marie-Virginie; Ben Jrad, Amani; Raviglione, Delphine; Zhou, Yuxiang; Bertrand, Cédric

    2017-06-28

    Pesticides are regularly used for a variety of applications and are disseminated throughout the environment. These substances may have significant negative impacts. To date, the half-life, t 1/2 , was often used to study the fate of pesticides in environmental matrices (water, soil, sediment). However, this value gives limited information. First, it does not evaluate the formation of by-products, resulting in the need for additional experiments to be performed to evaluate biodegradation and biotransformation products. T 1/2 also fails to consider the chemical's impact on biodiversity. Resilience time, a new and integrative proxy, was recently proposed as an alternative to t 1/2 , with the potential to evaluate all the post-application effects of the chemical on the environment. The 'Environmental Metabolic Footprinting' (EMF) approach, giving an idea of the resilience time, was used to evaluate the impact of botanicals on soil. The goal is to optimise the EMF to study the impact of a microbial insecticide, the Bacillus thuringiensis israelensis (Bti), on sediment. The difficulty of this work lies in the commercial solution of Bti that is really complex, and this complexity yields chromatograms that are extremely difficult to interpret; t 1/2 cannot be used. No methodologies currently exist to monitor the impact of these compounds on the environment. We will test the EMF to determine if it is sensitive enough to tolerate such complex mixtures. A pure chemical insecticide, the α-cypermethrin, will be also studied. The article shows that the EMF is able to distinguish meta-metabolome differences between control and exposed (with Bti) sediments.

  19. Direct measurement of the half-life of Rb{sup 87}; Mesure directe de la periode du rubidium-87; Pryamoe izmerenie poluraspada rubidiya-87; Medicion directa del periodo del {sup 87}Rb

    Energy Technology Data Exchange (ETDEWEB)

    McNair, A; Wilson, H W [United Kingdom Atomic Energy Authority, Aldermaston, Berks. (United Kingdom)

    1962-01-15

    The half-life of Rb{sup 87} has been measured directly by determining the specific activity by a counting method. The half-lives previously obtained lie in the range 4 - 6 x 10{sup 10} years, a value of 5 x 10{sup 10} years being taken usually. Direct counting is rather difficult because of the presence of a large number of very-low-energy electrons in the Rb{sup 87} spectrum. However, it is clearly very desirable to obtain a precise value by the counting method and this the authors have tried to do. In these measurements special attention must be paid to the reduction of thickness of source and of source backing. To increase the accuracy of the measurements, the following methods were used. The source thickness was reduced by use of (i) a 4-{pi} proportional counter of large source area (up to 100 cm{sup 2}), (ii) anti-coincidence operation to reduce background, and (iii) enriched Rb{sup 87} which permits a four-fold reduction in source thickness for a given activity. By these methods, sources down to 5 {mu}g/cm{sup 2} have been measured. Also the relationship between half-life and source thickness was examined so that correction could be made for the very small absorption which remained. The effect of source backing thickness is not so great and can be calculated from (i) the difference in count-rates on either side of the thin supports used and (ii) a study of dependence of half-life on source support thickness. These experiments give a value of about 5.25 x 10{sup 10} years for the half-life. (author) [French] On a mesure la periode du Tubidium-87 directement, en determinant l'activite specifique par comptage. Les periodes obtenues anterieurement se situent entre 4 et 6 {center_dot} 10{sup 10} ans; la valeur habituellement adoptee est de 5 {center_dot} 10{sup 10} ans. Le comptage direct est d'un emploi assez difficile par suite de la presence d'un grand nombre d'electrons de tres faible energie dans le spectre du rubidium-87. Il n'en serait pas moins tres utile

  20. Metabonomics analysis of plasma reveals the lactate to cholesterol ratio as an independent prognostic factor of short-term mortality in acute heart failure.

    Directory of Open Access Journals (Sweden)

    Franck Desmoulin

    Full Text Available OBJECTIVE: Mortality in heart failure (AHF remains high, especially during the first days of hospitalization. New prognostic biomarkers may help to optimize treatment. The aim of the study was to determine metabolites that have a high prognostic value. METHODS: We conducted a prospective study on a training cohort of AHF patients (n = 126 admitted in the cardiac intensive care unit and assessed survival at 30 days. Venous plasmas collected at admission were used for (1H NMR--based metabonomics analysis. Differences between plasma metabolite profiles allow determination of discriminating metabolites. A cohort of AHF patients was subsequently constituted (n = 74 to validate the findings. RESULTS: Lactate and cholesterol were the major discriminating metabolites predicting 30-day mortality. Mortality was increased in patients with high lactate and low total cholesterol concentrations at admission. Accuracies of lactate, cholesterol concentration and lactate to cholesterol (Lact/Chol ratio to predict 30-day mortality were evaluated using ROC analysis. The Lact/Chol ratio provided the best accuracy with an AUC of 0.82 (P < 0.0001. The acute physiology and chronic health evaluation (APACHE II scoring system provided an AUC of 0.76 for predicting 30-day mortality. APACHE II score, Cardiogenic shock (CS state and Lact/Chol ratio ≥ 0.4 (cutoff value with 82% sensitivity and 64% specificity were significant independent predictors of 30-day mortality with hazard ratios (HR of 1.11, 4.77 and 3.59, respectively. In CS patients, the HR of 30-day mortality risk for plasma Lact/Chol ratio ≥ 0.4 was 3.26 compared to a Lact/Chol ratio of < 0.4 (P = 0.018. The predictive power of the Lact/Chol ratio for 30-day mortality outcome was confirmed with the independent validation cohort. CONCLUSION: This study identifies the plasma Lact/Chol ratio as a useful objective and simple parameter to evaluate short term prognostic and could be integrated into quantitative

  1. Abstracts of the 6. Brazilian meeting on plasma physics

    International Nuclear Information System (INIS)

    2001-01-01

    Theoretical and experimental short communications are presented on the following subjects: plasma, ionized gases, plasma waves and instability, plasma diagnostic and heating, probes, magnetic confinements and plasma instability

  2. A randomized clinical trial evaluating plasma rich in growth factors (PRGF-Endoret) versus hyaluronic acid in the short-term treatment of symptomatic knee osteoarthritis.

    Science.gov (United States)

    Sánchez, Mikel; Fiz, Nicolás; Azofra, Juan; Usabiaga, Jaime; Aduriz Recalde, Enmanuel; Garcia Gutierrez, Antonio; Albillos, Javier; Gárate, Ramón; Aguirre, Jose Javier; Padilla, Sabino; Orive, Gorka; Anitua, Eduardo

    2012-08-01

    This multicenter, double-blind clinical trial evaluated and compared the efficacy and safety of PRGF-Endoret (BTI Biotechnology Institute, Vitoria-Gasteiz, Spain), an autologous biological therapy for regenerative purposes, versus hyaluronic acid (HA) as a short-term treatment for knee pain from osteoarthritis. We randomly assigned 176 patients with symptomatic knee osteoarthritis to receive infiltrations with PRGF-Endoret or with HA (3 injections on a weekly basis). The primary outcome measure was a 50% decrease in knee pain from baseline to week 24. As secondary outcomes, we also assessed pain, stiffness, and physical function using the Western Ontario and McMaster Universities Osteoarthritis Index; the rate of response using the criteria of the Outcome Measures for Rheumatology Committee and Osteoarthritis Research Society International Standing Committee for Clinical Trials Response Criteria Initiative (OMERACT-OARSI); and safety. The mean age of the patients was 59.8 years, and 52% were women. Compared with the rate of response to HA, the rate of response to PRGF-Endoret was 14.1 percentage points higher (95% confidence interval, 0.5 to 27.6; P = .044). Regarding the secondary outcome measures, the rate of response to PRGF-Endoret was higher in all cases, although no significant differences were reached. Adverse events were mild and evenly distributed between the groups. Plasma rich in growth factors showed superior short-term results when compared with HA in a randomized controlled trial, with a comparable safety profile, in alleviating symptoms of mild to moderate osteoarthritis of the knee. Level I, randomized controlled multicenter trial. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  3. The effect of platelet-rich plasma on the outcome of short-term narrowband-ultraviolet B phototherapy in the treatment of vitiligo: a pilot study.

    Science.gov (United States)

    Ibrahim, Zeinab A; El-Ashmawy, Amal A; El-Tatawy, Rania A; Sallam, Fersan A

    2016-06-01

    Narrowband - ultraviolet B (NB-UVB) is an emerging, effective, and safe therapy for vitiligo, but the treatment course often requires a long duration of time which may carry a potential risk for various side effects and patients' noncompliance. To explore the effect of platelet-rich plasma (PRP) injection on the outcome of short-term NB-UVB therapy for the patients with stable vitiligo. The study included 60 stable vitiligo patients with overall symmetrical lesions. For each patient, the left side of the body was treated with NB-UVB alone (control side) while the right side was treated with NB-UVB therapy in addition to intradermal injection of PRP, every 2 weeks for 4 months. There was statistically highly significant improvement in the repigmentation in the combination group(PRP plus NB-UVB) compared with NB-UVB group. Intradermal PRP injection in combination with NB-UVB could be considered as a simple, safe, tolerable, and cheap technique for treatment of vitiligo. It shortens the duration of NB-UVB therapy and is expected to increase patient compliance. Longer follow-up is needed. © 2015 Wiley Periodicals, Inc.

  4. Half-Life Studies of Radiocaesium in Humans; Etudes sur la Periode de Radiocesium chez l'Homme; 0418 0421 0421 041b 0415 0414 ; Estudio sobre el Periodo Biologico del Radiocesio en el Hombre

    Energy Technology Data Exchange (ETDEWEB)

    Naversten, Y.; Liden, K. [Radiation Physics Department, University of Lund (Sweden)

    1964-11-15

    The retention of caesium-137 in humans has been studied in several cases. Two adult men were intravenously administered a small quantity of caesium-137. They were followed about 300 days by frequent whole-body counting and with excreta collection during the initial period. The retention decreased as a sum of two exponentials. The slowest compartment decreased with a half-life of about 75 d. One of them was also given caesium-137 orally 2 years later with the same excretion pattern obtained as after intravenous injection. The excretion rate of caesium-137 has also been studied in a different way for large groups of men, women and children through comparison with diet data. From a group of 10 people, voluntarily changing their diet, the average excretion rate could be calculated from whole-body counting at an interval of six weeks. The excretion also has been obtained from a study on two people after an oral administration of caesium-132. Detailed results on these studies will be given particularly with respect to the elimination rate of caesium, i.e. the biological half-life and its variation with sex and age. On the average, half-lives ranging from 30 to 90 d have been obtained. (author) [French] La retention de cesium 137 chez l'homme a ete etudiee sur plusieurs sujets. Ainsi, on a administre a deux hommes adultes, par voie intraveineuse, une petite quantite de cesium 137. On les a suivis pendant 300 j environ en faisant de frequents dosages de l'activite du corps et en recueillant les excreta au debut de la periode. La fonction qui representait la decroissance de la retention est une somme de deux exponentielles. La fraction qui decroissait le plus lentement avait une periode d'environ 75 j. Deux ans plus tard, on a administre du cesium 137 a un des deux sujets, par voie buccale, et on a obtenu le meme regime d'elimination qu'apres l'injection intraveineuse. On a aussi etudie le taux d'elimination de cesium 137 par une methode differente pour des groupes

  5. Short-lived non-coding transcripts (SLiTs): Clues to regulatory long non-coding RNA.

    Science.gov (United States)

    Tani, Hidenori

    2017-03-22

    Whole transcriptome analyses have revealed a large number of novel long non-coding RNAs (lncRNAs). Although the importance of lncRNAs has been documented in previous reports, the biological and physiological functions of lncRNAs remain largely unknown. The role of lncRNAs seems an elusive problem. Here, I propose a clue to the identification of regulatory lncRNAs. The key point is RNA half-life. RNAs with a long half-life (t 1/2 > 4 h) contain a significant proportion of ncRNAs, as well as mRNAs involved in housekeeping functions, whereas RNAs with a short half-life (t 1/2 regulatory ncRNAs and regulatory mRNAs. This novel class of ncRNAs with a short half-life can be categorized as Short-Lived non-coding Transcripts (SLiTs). I consider that SLiTs are likely to be rich in functionally uncharacterized regulatory RNAs. This review describes recent progress in research into SLiTs.

  6. Plasma cytokine profiles in HIV-1 infected patients developing neuropathic symptoms shortly after commencing antiretroviral therapy: a case-control study.

    Science.gov (United States)

    Van der Watt, Johan J; Wilkinson, Katalin A; Wilkinson, Robert J; Heckmann, Jeannine M

    2014-02-10

    In patients infected with human immunodeficiency virus 1 (HIV-1) neuropathic symptoms may develop within weeks of starting combination antiretroviral therapy (cART). This timing coincides with the occurrence of immune reconstitution inflammatory syndrome. Our objective was to investigate the longitudinal association of plasma cytokine and soluble receptor concentrations with incident neuropathic symptoms within 12 weeks of starting programme-based cART in a nested case-control study. One hundred and twenty adults without neuropathic symptoms and about to initiate cART were followed longitudinally for 24 weeks after cART initiation. Subjects were examined for peripheral neuropathy at baseline (pre-cART) and 2-, 4-, 12- and 24 weeks thereafter. Individuals developing neuropathic symptoms within 12 weeks of starting cART were matched in a nested case-control design with those remaining symptom-free for at least 24 weeks. Plasma was collected at each visit. Cytokines and soluble receptors were quantified using multiplex immunometric assays. Incident neuropathic symptoms occurred in 32 (27%) individuals within 12 weeks of starting cART for the first time. Cytokine concentrations increased at 2 weeks, irrespective of symptom-status, returning to baseline concentrations at 12 weeks. Compared to the control group, the symptomatic group had higher baseline levels of interleukin-1 receptor (IL-1R)-antagonist. The symptomatic group also showed greater increases in soluble interleukin-2 receptor-alpha and tumour necrosis factor (TNF) receptor-II levels at week 2 and soluble interleukin-6 receptor levels at week 12. Ratios of pro-inflammatory- vs anti-inflammatory cytokines were higher for TNF-alpha/IL-4 (p = 0.022) and interferon-gamma/IL-10 (p = 0.044) in those developing symptoms. After 24 weeks of cART, the symptomatic group showed higher CD4+ counts (p = 0.002). The initiation of cART in previously treatment naïve individuals was associated with a cytokine

  7. Preclinical pharmacokinetics, tissue distribution and plasma protein binding of sodium (±-5-bromo-2-(α-hydroxypentyl benzoate (BZP, an innovative potent anti-ischemic stroke agent

    Directory of Open Access Journals (Sweden)

    Xin Tian

    2016-08-01

    Full Text Available Sodium (±-5-bromo-2-(α-hydroxypentyl benzoate (BZP is a potential cardiovascular drug and exerts potent neuroprotective effect against transient and long-term ischemic stroke in rats. BZP could convert into 3-butyl-6-bromo-1(3H-isobenzofuranone (Br-NBP in vitro and in vivo. However, the pharmacokinetic profiles of BZP and Br-NBP still have not been evaluated. For the purpose of investigating the pharmacokinetic profiles, tissue distribution and plasma protein binding of BZP and Br-NBP, a rapid, sensitive and specific method based on liquid chromatography coupled to mass spectrometry (LC-MS/MS has been developed for determination of BZP and Br-NBP in biological samples. The results indicated that BZP and Br-NBP showed a short elimination half-life, and pharmacokinetic profile in rats (3, 6 and 12 mg/kg; i.v. and beagle dogs (1, 2 and 4 mg/kg; i.v.gtt were obtained after single dosing of BZP. After multiple dosing of BZP, there was no significant accumulation of BZP and Br-NBP in the plasma of rats and beagle dogs. Following i.v. single dose (6 mg/kg to rats, BZP and Br-NBP were distributed rapidly into all tissues examined, with the highest concentrations of BZP and Br-NBP in lung and kidney, respectively. The brain distribution of Br-NBP in middle cerebral artery occlusion (MCAO rats was more than in normal rats (P<0.05. The plasma protein binding degree of BZP at three concentrations (8000, 20000 and 80000 ng/mL from rat, beagle dog and human plasma were 98.1~98.7%, 88.9~92.7% and 74.8%~83.7% respectively. In conclusion, both BZP and Br-NBP showed short half-life, good dose-linear pharmacokinetic profile, wide tissue distribution and different degree protein binding to various species plasma. This was the first preclinical pharmacokinetic investigation of BZP and Br-NBP in both rats and beagle dogs, which provided vital guidance for further preclinical research and the subsequent clinical trials.

  8. Pro B-type natriuretic peptide plasma value: a new criterion for the prediction of short- and long-term outcomes after transcatheter aortic valve implantation.

    Science.gov (United States)

    López-Otero, Diego; Trillo-Nouche, Ramiro; Gude, Francisco; Cid-Álvarez, Belen; Ocaranza-Sanchez, Raimundo; Alvarez, Melisa Santas; Lear, Pamela V; Gonzalez-Juanatey, José R

    2013-09-30

    To determine the prognostic value of pro B-type natriuretic peptide (pro-BNP) to predict mortality after transcatheter aortic valve implantation (TAVI). Logistic EuroSCORE (LES) overestimates observed mortality after TAVI. A new risk score specific to TAVI is needed to accurately assess mortality and outcome. Eighty-five patients were included. Indications for TAVI were nonoperable or surgically high-risk patients (LES>20%). Pro-BNP was measured 24h before the procedure. Cox proportional hazards model was used to evaluate clinical factors. The predictive accuracy of these Cox models was determined by using time-dependent receiver operating characteristic (ROC) curves. Pro-BNP levels (log-transformed) were significantly higher in non-survivors than in survivors at 30 days (3.36 ± 0.43 vs. 3.81 ± 0.43, p<0.004) and at the end of follow-up (3.34 ± 0.42 vs. 3.63 ± 0.48, p<0.011). Multivariate analysis revealed that only increased log pro-BNP levels were associated with higher mortality rate at short [hazard ratio (HR) (95% confidence intervals (CI)]=5.35 (1.74-16.5), p=0.003] and long-term follow-ups [HR=11 (CI: 1.51-81.3), p=0.018]. LES was not associated with increased mortality at either time point [HR=1.03 (CI: 0.95-1.10), p=0.483 and HR=1.03 (CI: 0.98-1.07), p=0.230, respectively]. At 30, 90, 180, and 365 days, the c-index was 0.72 for log pro-BNP and 0.63 for LES (p=0.044). Pre-procedure log transform of plasma pro-BNP levels are an independent and strong predictor of short- and long-term outcomes after TAVI and are more discriminatory than LES. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  9. Higher admission fasting plasma glucose levels are associated with a poorer short-term neurologic outcome in acute ischemic stroke patients with good collateral circulation.

    Science.gov (United States)

    Wang, Feng; Jiang, Beisi; Kanesan, Lasheta; Zhao, Yuwu; Yan, Bernard

    2018-04-12

    In this retrospective study, we sought to delineate the collateral circulation status of acute ischemic stroke patients by CT perfusion and evaluate 90-day modified Rankin Scale (mRS) scores of patients with good or poor collaterals and its correlation with admission fasting plasma glucose (FPG). We enrolled acute ischemic stroke patients who presented to our hospital 4.5 h within an onset of the first episode between January 2009 and December 2015. Neurological assessment was performed using the 90-day mRS scores (0-2 for a favorable and 3-6 for an unfavorable neurologic outcome). Relative filling time delay (rFTD) was evaluated by CT perfusion scan. The primary outcomes were 90-day mRS scores stratified by good (rFTD ≤ 4 s) versus poor collateral circulation (rFTD > 4 s). Totally 270 patients were included, and 139 (51.5%) patients achieved a favorable neurologic outcome. One hundred eighty-five (68.5%) patients had good collateral circulation. Significantly greater portions of patients with good collateral circulation (60.5%, 112/185) achieved a favorable neurologic outcome compared to those with poor collateral circulation (31.8%, 27/85) (P collateral circulation achieving a favorable neurologic outcome had significantly lower baseline FPG (6.6 ± 1.96) than those with good collateral circulation achieving an unfavorable neurologic outcome (8.12 ± 4.02; P = 0.002). Spearman correlation analysis showed that rFTD significantly correlated with 90-day mRS scores (adjusted r = 0.258; P collateral circulation. FPG and rFTD may serve as useful predictors of short-term patient outcome and could be used for risk stratification in clinical decision making.

  10. Nonlinear evolutions of an ultra-intense ultra-short laser pulse in a rarefied plasma through a new quasi-static theory

    Science.gov (United States)

    Yazdanpanah, J.

    2018-02-01

    In this paper, we present a new description of self-consistent wake excitation by an intense short laser pulse, based on applying the quasi-static approximation (slow variations of the pulse-envelope) in the instantaneous Lorentz-boosted pulse co-moving frame (PCMF), and best verify our results through comparison with particle-in-cell simulations. According to this theory, the plasma motion can be treated perturbatively in the PCMF due to its high initial-velocity and produces a quasi-static wakefield in this frame. The pulse envelope, on the other hand, is governed by a form of the Schrödinger equation in the PCMF, in which the wakefield acts as an effective potential. In this context, pulse evolutions are characterized by local conservation laws resulted from this equation and subjected to Lorentz transformation into the laboratory frame. Using these conservation laws, precise formulas are obtained for spatiotemporal pulse evolutions and related wakefield variations at initial stages, and new equations are derived for instantaneous group velocity and carrier frequency. In addition, based on properties of the Schrödinger equation, spectral-evolutions of the pulse are described and the emergence of an anomalous dispersion branch with linear relation ω ≈ ck (c is the light speed) is predicted. Our results are carefully discussed versus previous publications and the significance of our approach is described by showing almost all suggestive definitions of group-velocity based on energy arguments fail to reproduce our formula and correctly describe the instantaneous pulse-velocity.

  11. High-Strength Ultra-Fine-Grained Hypereutectic Al-Si-Fe-X (X = Cr, Mn) Alloys Prepared by Short-Term Mechanical Alloying and Spark Plasma Sintering.

    Science.gov (United States)

    Průša, Filip; Bláhová, Markéta; Vojtěch, Dalibor; Kučera, Vojtěch; Bernatiková, Adriana; Kubatík, Tomáš František; Michalcová, Alena

    2016-11-30

    In this work, Al-20Si-10Fe-6Cr and Al-20Si-10Fe-6Mn (wt %) alloys were prepared by a combination of short-term mechanical alloying and spark plasma sintering. The microstructure was composed of homogeneously dispersed intermetallic particles forming composite-like structures. X-ray diffraction analysis and TEM + EDS analysis determined that the α-Al along with α-Al 15 (Fe,Cr)₃Si₂ or α-Al 15 (Fe,Mn)₃Si₂ phases were present, with dimensions below 130 nm. The highest hardness of 380 ± 7 HV5 was observed for the Al-20Si-10Fe-6Mn alloy, exceeding the hardness of the reference as-cast Al-12Si-1Cu-1 Mg-1Ni alloy (121 ± 2 HV5) by nearly a factor of three. Both of the prepared alloys showed exceptional thermal stability with the hardness remaining almost the same even after 100 h of annealing at 400 °C. Additionally, the compressive strengths of the Al-20Si-10Fe-6Cr and Al-20Si-10Fe-6Mn alloys reached 869 MPa and 887 MPa, respectively, and had virtually the same values of 870 MPa and 865 MPa, respectively, even after 100 h of annealing. More importantly, the alloys showed an increase in ductility at 400 °C, reaching several tens of percent. Thus, both of the investigated alloys showed better mechanical properties, including superior hardness, compressive strength and thermal stability, as compared to the reference Al-10Si-1Cu-1Mg-1Ni alloy, which softened remarkably, reducing its hardness by almost 50% to 63 ± 8 HV5.

  12. High-Strength Ultra-Fine-Grained Hypereutectic Al-Si-Fe-X (X = Cr, Mn) Alloys Prepared by Short-Term Mechanical Alloying and Spark Plasma Sintering

    Science.gov (United States)

    Průša, Filip; Bláhová, Markéta; Vojtěch, Dalibor; Kučera, Vojtěch; Bernatiková, Adriana; Kubatík, Tomáš František; Michalcová, Alena

    2016-01-01

    In this work, Al-20Si-10Fe-6Cr and Al-20Si-10Fe-6Mn (wt %) alloys were prepared by a combination of short-term mechanical alloying and spark plasma sintering. The microstructure was composed of homogeneously dispersed intermetallic particles forming composite-like structures. X-ray diffraction analysis and TEM + EDS analysis determined that the α-Al along with α-Al15(Fe,Cr)3Si2 or α-Al15(Fe,Mn)3Si2 phases were present, with dimensions below 130 nm. The highest hardness of 380 ± 7 HV5 was observed for the Al-20Si-10Fe-6Mn alloy, exceeding the hardness of the reference as-cast Al-12Si-1Cu-1 Mg-1Ni alloy (121 ± 2 HV5) by nearly a factor of three. Both of the prepared alloys showed exceptional thermal stability with the hardness remaining almost the same even after 100 h of annealing at 400 °C. Additionally, the compressive strengths of the Al-20Si-10Fe-6Cr and Al-20Si-10Fe-6Mn alloys reached 869 MPa and 887 MPa, respectively, and had virtually the same values of 870 MPa and 865 MPa, respectively, even after 100 h of annealing. More importantly, the alloys showed an increase in ductility at 400 °C, reaching several tens of percent. Thus, both of the investigated alloys showed better mechanical properties, including superior hardness, compressive strength and thermal stability, as compared to the reference Al-10Si-1Cu-1Mg-1Ni alloy, which softened remarkably, reducing its hardness by almost 50% to 63 ± 8 HV5. PMID:28774094

  13. Characteristics of short distance field of a source radiating at electronic frequencies in a ionospheric plasma. Applications to density and electron temperature measurement by mutual impedance probe

    International Nuclear Information System (INIS)

    Debrie, R.

    1983-06-01

    Realization of a new type of radio-frequency probe, the mutual-impedance probe (or the quadrupole probe) is developed. Theoretical results obtained with a cold plasma description of the ionized medium with static magnetic field. Transfer impedance between two dipoles in an homogeneous hot and isotope plasma is then calculated. In equatorial ionosphere, measurements made by the H.F. quadrupole probe, in the Veronique rocket, during the Cisaspe experiment, have been interpreted with this hot plasma theory. The influence of a plasma drift with respect to the emitter dipole is analyzed. The influence of a static magnetic field in hot and homogeneous plasma, on the frequency response curve of the mutual impedance is studied. For, in ionospheric plasmas of auroral and polar zones, the earth magnetic field is no more negligible and gives to the plasma dielectric, strongly anisotropic, properties well described by the microscopic theory in hot magnetoplasma. The space time fast evolution of characteristics of plasma encountered in space experiments has been shown up with a new method of measurement the self-oscillating quadrupole probe. The work synthesis is put in a concrete form on the polar satellite Aureol-3 the first results of which are presented. This satellite allows a precise study of ionosphere auroral zones. At last, it is shown that methods developed for electron density and temperature measurements can be transposed in low frequency. In this case, measurements with quadrupole probe allow to get the ion average mass by lower hybrid frequency excitation [fr

  14. Be-7 as a tracer for short-term soil surface changes - opportunities and limitations

    Science.gov (United States)

    Baumgart, Philipp

    2013-04-01

    Within the last 20 years the cosmogenic nuclide Beryllium-7 was successfully established as a suitable tracer element to detect soil surface changes with a high accuracy. Particularly soil erosion rates from single precipitation events are in the focus of different studies due to the short radioactive half-life of the Be-7 isotope. High sorption at topmost soil particles and immobility at given pH-values enable fine-scaled erosion modelling down to 2 mm increments. But some important challenging limitations require particular attention, starting from sampling up to the final data evaluation. E.g. these are the realisation of the fine increment soil collection, the limiting amount of measurable samples per campaign due to the short radioactive half-life and the specific requirements for the detector measurements. Both, the high potential and the challenging limitations are presented as well as future perspectives of that tracer method.

  15. Development and application of the generator for the short-living nuclides production

    International Nuclear Information System (INIS)

    Tsejner, A.

    1979-01-01

    The results are stated of investigations by means of radioisotopes on the substance transfer in technological equipment. For these purposes, in most cases, nuclides with high gamma-activity are used and, if possible, having short half-life because the short half-life gives certain advantages in the cases when it is impossible to store radioactive substances in the technological equipment for a long time. It is noted that in connection with short half-life of the nucludes used for labelling and for the economic and radiation safety reasons, activity of these nuclides can not be high. It has been established that the most suitable nuclide for the labelling purpose is lanthanum-140 produced either in a nuclear reactor, or by means of separation from barium=-140 transforming into lanthanum-140 in an isotopic generator. Some methods of lanthanum separation from barium are described, in particular, in the isotopic generator described, barium is adsorbed on the cation-exchanger KPS-200 having high enough stability with respect to the ionozing radiations. As an eluent the 10 -2 M solution of the complexone (Na 2 - EDTA) was used. The complexone solution can be easely obtained and, because of the hydrolysis, it serves as a buffer solution. The data are given for radiation purity and yield of lanthanum-=140 [ru

  16. Turnover of adenosine in plasma of human and dog blood

    International Nuclear Information System (INIS)

    Moeser, G.H.S.; Schrader, J.; Deussen, A.

    1989-01-01

    To determine half-life and turnover of plasma adenosine, heparinized blood from healthy volunteers was incubated with radiolabeled adenosine in the physiological concentration range of 0.1-1 microM. Plasma levels of adenosine in vitro were 82 +/- 14 nM and were similar to those determined immediately after blood collection with a ''stopping solution.'' Dipyridamole (83 microM) and erythro-9(2-hydroxynon-3yl)-adenine (EHNA) (8 microM) did not measurably alter basal adenosine levels but completely blocked the uptake of added adenosine. Inhibition of ecto-5'-nucleotidase with 100 microM alpha, beta-methyleneadenosine 5'-diphosphate (AOPCP) reduced plasma adenosine to 22 +/- 6 nM. For the determination of adenosine turnover, the decrease in specific radioactivity of added [ 3 H]adenosine was measured using a dipyridamole-containing stopping solution. Without altering basal adenosine levels, the half-life was estimated to be 0.6 s. Similar experiments were carried out with washed erythrocytes or in the presence of AOPCP, yielding half-lives of 0.7 and 0.9 s, respectively. When the initial adenosine concentration was 1 microM, its specific activity decreased by only 11% within 5 s, whereas total plasma adenosine exponentially decreased with a half-life of 1.5 s. Venous plasma concentrations were measured after relief of a 3-min forearm ischemia. Changes in plasma adenosine did not correlate well with changes in blood flow but were augmented in the presence of dipyridamole

  17. 10. LAWPP: Latin American workshop on plasma physics; 7. EBFP: Brazilian meeting on plasma physics. Abstracts

    International Nuclear Information System (INIS)

    2003-01-01

    Theoretical and experimental short communications are presented on plasma and fusion covering the following subjects: plasma production, confinement, plasma waves, diagnostics, heating, tokamak, impurities, astrophysics plasma and technological applications

  18. Generation of shock fronts in the interaction of the short pulses of intense laser light in supercritical plasma; Generacion de frentes de choque en la interaccion de pulsos cortos de luz laser intensa en plasmas supercriticos

    Energy Technology Data Exchange (ETDEWEB)

    Lopez V, V.E

    2004-07-01

    The plasma is the state of the matter but diffused in the nature. The sun and the stars big heaps of hot plasma can be considered. The external surface of the terrestrial atmosphere this recovered by a layer of plasma. All gassy discharge (lightning spark arch etc.) this related with the formation of plasma. This way, 99 percent of our environment this formed almost of plasma. It is denominated plasma to the ionized gas in the one which all or most of the atoms have lost one or several of the electrons that belonged him, becoming positive ions and free electrons. In the plasma certain physical characteristics exist as for their behavior like they are the collective movements the quasi neutrality, the Debye length, the uncertainty etc. All these behaviors make that the study of the plasma is complex. For this they exist technical of numeric simulation joined to the technological advance of big computers of more capacity and prosecution speed. The simulation techniques of particles are those where a numeric code is built based on a model or theory of a system that it is wanted to investigate. This way through the simulation the results are compared with those theoretical predictions based on an analytic model. The applications of the physics of the plasma are multiple however we focus ourselves in the interaction laser-plasma. Both finish decades of investigation in the interaction of lasers with plasma they have been carried out in laboratories of Europe, Japan, United States. This studies concern the propagation of intense light laser in dense plasma homogeneous, the radiation absorption in cold plasma and problems related with the generation of suprathermal electrons among others. Other areas of the physics of the plasma-laser interaction that it has been considerable attention is the broadly well-known field as parametric uncertainties induced instabilities by the light and that they include the dispersions for example stimulated Raman and Brillouin being able to

  19. Nevirapine, sodium concentration and HIV-1 RNA in breast milk and plasma among HIV-infected women receiving short-course antiretroviral prophylaxis

    DEFF Research Database (Denmark)

    Salado-Rasmussen, Kirsten; Theilgaard, Zahra Persson; Chiduo, Mercy G.

    2015-01-01

    and breast milk after intrapartum single-dose nevirapine combined with either 1-week tail of Combivir (zidovudine/lamivudine) or single-dose Truvada (tenofovir/emtricitabine). Methods Maternal plasma and bilateral breast milk samples were collected between April 2008 and April 2011 at 1, 4 and 6 weeks...... postpartum from HIV-infected Tanzanian women. Moreover, plasma samples were collected at delivery from mother and infant. Results HIV-1 RNA was quantified in 1,212 breast milk samples from 273 women. At delivery, 96% of the women and 99% of the infants had detectable nevirapine in plasma with a median...... (interquartile range, IQR) of 1.5 μg/mL (0.75–2.20 μg/mL) and 1.04 μg/mL (0.39–1.71 μg/mL), respectively (P women had detectable nevirapine in plasma and breast milk, with a median (IQR) of 0.13 μg/mL (0.13–0.39 μg/mL) and 0.22 μg/mL (0.13–0.34 μg...

  20. Structure and mechanical properties of Al-Si-Fe alloys prepared by short-term mechanical alloying and Spark Plasma Sintering

    Czech Academy of Sciences Publication Activity Database

    Průša, J.; Vojtěch, D.; Bláhová, M.; Michalcová, A.; Kubatík, Tomáš František; Čížek, J.

    2015-01-01

    Roč. 75, June (2015), s. 65-75 ISSN 0261-3069 Institutional support: RVO:61389021 Keywords : Aluminium alloy s * Mechanical Properties * Microstructure * Mechanical alloy ing * Spark-Plasma Sintering Subject RIV: JG - Metallurgy Impact factor: 3.997, year: 2015 http://www.sciencedirect.com/science/article/pii/S0261306915000990#

  1. Predictive Value of Plasma Glucose Level on Admission for Short and Long Term Mortality in Patients With ST-Elevation Myocardial Infarction Treated With Primary Percutaneous Coronary Intervention

    NARCIS (Netherlands)

    Hoebers, Loes P.; Damman, Peter; Claessen, Bimmer E.; Vis, Marije M.; Baan, Jan; van Straalen, Jan P.; Fischer, Johan; Koch, Karel T.; Tijssen, Jan G. P.; de Winter, Robbert J.; Piek, Jan J.; Henriques, Jose P. S.

    2012-01-01

    Published reports describe a strong association between plasma glucose levels on admission and mortality in patients who undergo primary percutaneous coronary intervention for ST-segment elevation myocardial infarction. The aim of this study was to assess the predictive value of admission glucose

  2. Generation of shock fronts in the interaction of short pulses of intense laser light in supercritical plasma; Generacion de frentes de choque en la interaccion de pulsos cortos de luz laser intensa en plasmas supercriticos

    Energy Technology Data Exchange (ETDEWEB)

    Lopez V, V.E. [ITESST, 52650 Estado de Mexico (Mexico); Ondarza R, R. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2004-07-01

    The investigation of the laser interaction with plasma has been carried out mainly in laboratories of Europe, Japan and United States during the last decades. This studies concern the propagation of intense light laser in a non homogeneous plasma, the radiation absorption and the generation of suprathermal electrons, among others. Numerical simulations made by Denavit, for radiation pulses for up of 10{sup 20} W/cm{sup 2} on solid targets, have allowed to observe the generation of ionic crash fronts with high propagation speeds. In this work it is expanded the study of this effect through algorithms of particles simulation. (Author)

  3. Plasma ceramide levels are altered in low and normal birth weight men in response to short-term high-fat overfeeding

    DEFF Research Database (Denmark)

    Ribel-Madsen, Amalie; Ribel-Madsen, Rasmus; Nielsen, Kristian Fog

    2018-01-01

    Low birth weight (LBW) individuals have an increased risk of developing insulin resistance and type 2 diabetes compared with normal birth weight (NBW) individuals. We hypothesised that LBW individuals exhibit an increased fatty acid flux into lipogenesis in non-adipose tissue with a resulting...... accumulation of lipotoxic lipids, including ceramides, in the blood. Therefore, we measured fasting plasma levels of 27 ceramides in 18 young, healthy, LBW men and 25 NBW controls after an isocaloric control diet and a 5-day high-fat, high-calorie diet by HPLC-HRMS. LBW men did not show elevated plasma......:0–18:1/d18:1–18:0 and d18:1–24:2/d18:2–24:1 levels and increased the d18:0–24:1a level in response to overfeeding. Plasma d18:0–24:1a and total ceramide levels were positively associated with the fasting blood glucose level and endogenous glucose production after the control diet, and the total ceramide...

  4. The effects of increasing doses of 2 preparations of long-acting insulin on short-term plasma profiles of glucose and insulin in lactating dairy cows.

    Science.gov (United States)

    Winkelman, L A; Overton, T R

    2012-12-01

    Two experiments were conducted to investigate effects of administering increasing doses of 2 different preparations of long-acting insulin on the 24-h profiles of plasma glucose and insulin concentrations in mid lactation dairy cows. The 2 separately analyzed experiments investigated the effects administering either Humulin N (H), a neutral protamine Hagedorn insulin, or insulin glargine (Lantus, L), an insulin analog, at doses of 0 (control), 0.1, 0.2, and 0.4 IU/kg of body weight in a randomized complete block design. Sixteen cows (237±11 d in milk for H; 213±10 d in milk for L; mean ± SD) were used for each insulin preparation, resulting in n=4 for each dose within insulin preparation. Cows were fitted with a single jugular catheter on the day before the study. On the day of the study, cows were given treatments by subcutaneous injection of either sterile water or the designated insulin type and dose. Blood samples were taken hourly from the jugular catheter. Subcutaneous injection of both H and L resulted in linear decreases in plasma glucose concentrations, increased area under the curve, and decreased nadir for plasma glucose following administration of the insulin preparations. Plasma insulin concentration linearly increased with increasing dose of H. Though elevated concentrations of insulin were measurable in cows treated with H, they were not measurable in cows treated with L. Attempts to measure overall insulin concentrations and metabolites of L by a commercially available ELISA and a commercially available RIA kit were not successful and did not retrieve values that we felt truly represented the amount of insulin activity exhibited during this treatment. Both long-acting insulin preparations elicited insulin-like activity in lactating dairy cows, as evidenced by reduced plasma glucose concentrations. Given these results, the potential exists to use both H and L to study the effects of insulin in mid lactation dairy cows without the confounding

  5. Enhancement of laser-induced breakdown spectroscopy (LIBS) Detection limit using a low-pressure and short-pulse laser-induced plasma process.

    Science.gov (United States)

    Wang, Zhen Zhen; Deguchi, Yoshihiro; Kuwahara, Masakazu; Yan, Jun Jie; Liu, Ji Ping

    2013-11-01

    Laser-induced breakdown spectroscopy (LIBS) technology is an appealing technique compared with many other types of elemental analysis because of the fast response, high sensitivity, real-time, and noncontact features. One of the challenging targets of LIBS is the enhancement of the detection limit. In this study, the detection limit of gas-phase LIBS analysis has been improved by controlling the pressure and laser pulse width. In order to verify this method, low-pressure gas plasma was induced using nanosecond and picosecond lasers. The method was applied to the detection of Hg. The emission intensity ratio of the Hg atom to NO (IHg/INO) was analyzed to evaluate the LIBS detection limit because the NO emission (interference signal) was formed during the plasma generation and cooling process of N2 and O2 in the air. It was demonstrated that the enhancement of IHg/INO arose by decreasing the pressure to a few kilopascals, and the IHg/INO of the picosecond breakdown was always much higher than that of the nanosecond breakdown at low buffer gas pressure. Enhancement of IHg/INO increased more than 10 times at 700 Pa using picosecond laser with 35 ps pulse width. The detection limit was enhanced to 0.03 ppm (parts per million). We also saw that the spectra from the center and edge parts of plasma showed different features. Comparing the central spectra with the edge spectra, IHg/INO of the edge spectra was higher than that of the central spectra using the picosecond laser breakdown process.

  6. Short-Term Vitamin B-6 Restriction Does Not Affect Plasma Concentrations of Hydrogen Sulfide Biomarkers Lanthionine and Homolanthionine in Healthy Men and Women.

    Science.gov (United States)

    DeRatt, Barbara N; Ralat, Maria A; Gregory, Jesse F

    2016-03-09

    Suboptimal vitamin B-6 status is associated with increased cardiovascular disease risk, although the mechanism is unknown. The synthesis of the vasodilator hydrogen sulfide occurs through side reactions of the transsulfuration enzymes cystathionine β-synthase and cystathionine γ-lyase, with pyridoxal 5'-phosphate as a coenzyme. Two proposed hydrogen sulfide biomarkers, lanthionine and homolanthionine, are produced concurrently. To determine whether hydrogen sulfide production is reduced by vitamin B-6 deficiency, we examined the relations between plasma concentrations of lanthionine and homolanthionine, along with other components of the transsulfuration pathway (homocysteine, cystathionine, and Cys), in a secondary analysis of samples from 2 vitamin B-6 restriction studies in healthy men and women. Metabolite concentrations were measured in plasma from 23 healthy adults (12 men and 11 women) before and after 28-d controlled dietary vitamin B-6 restriction (0.37 ± 0.04 mg/d). Vitamin B-6 restriction effects on lanthionine and homolanthionine concentrations were assessed. Associations between hydrogen sulfide biomarkers, transsulfuration metabolites, and functional indicators of vitamin B-6 deficiency were analyzed by linear regression. Preprandial plasma lanthionine and homolanthionine concentrations ranged from 89.0 to 372 nmol/L and 5.75 to 32.3 nmol/L, respectively, in healthy adults. Mean lanthionine and homolanthionine concentrations were not affected by vitamin B-6 restriction (P restriction, homolanthionine was positively associated with functional indicators of vitamin B-6 deficiency, which differed from hypothesized negative associations. Plasma lanthionine was positively correlated with the concentration of its precursor, Cys, before (R 2 = 0.36; P = 0.002) and after (R 2 = 0.37; P = 0.002) restriction. Likewise, homolanthionine concentration was positively correlated with its precursor homocysteine, but only in vitamin B-6 adequacy (R 2 = 0.41; P

  7. Short-Term Vitamin B-6 Restriction Does Not Affect Plasma Concentrations of Hydrogen Sulfide Biomarkers Lanthionine and Homolanthionine in Healthy Men and Women123

    Science.gov (United States)

    DeRatt, Barbara N; Ralat, Maria A; Gregory, Jesse F

    2016-01-01

    Background: Suboptimal vitamin B-6 status is associated with increased cardiovascular disease risk, although the mechanism is unknown. The synthesis of the vasodilator hydrogen sulfide occurs through side reactions of the transsulfuration enzymes cystathionine β-synthase and cystathionine γ-lyase, with pyridoxal 5′-phosphate as a coenzyme. Two proposed hydrogen sulfide biomarkers, lanthionine and homolanthionine, are produced concurrently. Objective: To determine whether hydrogen sulfide production is reduced by vitamin B-6 deficiency, we examined the relations between plasma concentrations of lanthionine and homolanthionine, along with other components of the transsulfuration pathway (homocysteine, cystathionine, and Cys), in a secondary analysis of samples from 2 vitamin B-6 restriction studies in healthy men and women. Methods: Metabolite concentrations were measured in plasma from 23 healthy adults (12 men and 11 women) before and after 28-d controlled dietary vitamin B-6 restriction (0.37 ± 0.04 mg/d). Vitamin B-6 restriction effects on lanthionine and homolanthionine concentrations were assessed. Associations between hydrogen sulfide biomarkers, transsulfuration metabolites, and functional indicators of vitamin B-6 deficiency were analyzed by linear regression. Results: Preprandial plasma lanthionine and homolanthionine concentrations ranged from 89.0 to 372 nmol/L and 5.75 to 32.3 nmol/L, respectively, in healthy adults. Mean lanthionine and homolanthionine concentrations were not affected by vitamin B-6 restriction (P restriction, homolanthionine was positively associated with functional indicators of vitamin B-6 deficiency, which differed from hypothesized negative associations. Plasma lanthionine was positively correlated with the concentration of its precursor, Cys, before (R2 = 0.36; P = 0.002) and after (R2 = 0.37; P = 0.002) restriction. Likewise, homolanthionine concentration was positively correlated with its precursor homocysteine, but only in

  8. Plasma amino acid levels are elevated in young, healthy low birth weight men exposed to short-term high-fat overfeeding

    DEFF Research Database (Denmark)

    Ribel-Madsen, Amalie; Hellgren, Lars; Brøns, Charlotte

    2016-01-01

    Low birth weight (LBW) individuals exhibit a disproportionately increased, incomplete fatty acid oxidation and a decreased glucose oxidation, compared with normal birth weight (NBW) individuals, and furthermore have an increased risk of developing insulin resistance and type 2 diabetes. We...... and after a 5‐day high‐fat, high‐calorie diet. We demonstrated that LBW and NBW men increased plasma alanine levels and decreased valine and leucine/isoleucine levels in response to overfeeding. Also, LBW men had higher alanine, proline, methionine, citrulline, and total amino acid levels after overfeeding...

  9. Semisolid meal enriched in oat bran decreases plasma glucose and insulin levels, but does not change gastrointestinal peptide responses or short-term appetite in healthy subjects

    DEFF Research Database (Denmark)

    Juvonen, Kristiina R.; Salmenkallio-Marttila, Marjatta; Lyly, Marika

    2011-01-01

    types and amounts of DF exert are still poorly understood. METHODS AND RESULTS: We investigated the effects of wheat and oat brans alone and as combination in semisolid food matrix on postprandial appetite profile and gastrointestinal (GI) hormonal responses. Twenty healthy, normal-weight subjects (5...... including 5 g wheat bran DF + 5 g oat bran DF. Blood samples were drawn before and 15, 30, 45, 60, 90, 120 and 180 min after the test meals to determine plasma glucose, ghrelin, peptide YY (PYY) and serum insulin concentrations. Subjective profiles of appetite were assessed using visual analogue scales (VAS...

  10. Effect of storage in short--and long-term commercial semen extenders on the motility, plasma membrane and chromatin integrity of boar spermatozoa.

    Science.gov (United States)

    De Ambrogi, Marco; Ballester, Juan; Saravia, Fernando; Caballero, Ignacio; Johannisson, Anders; Wallgren, Margareta; Andersson, Magnus; Rodriguez-Martinez, Heriberto

    2006-10-01

    For artificial insemination (AI) in pigs, preservation of liquid boar semen at 16-20 degrees C is still common practice as sperm cryopreservation remains suboptimal in this species. To meet the different needs of the swine industry, several extenders have been developed to preserve semen in liquid form for short--and long-term storage. In the present study, three different commercial extenders devised for short-term (BTS+) or long-term preservation (MR-A and X-Cell), were used to test whether storage of semen from four mature, fertile boars at 17 degrees C for 96 h would affect sperm characteristics relevant for fertility, such as motility, membrane integrity and chromatin stability. Computer-assisted sperm analysis, and stainings with the acylated membrane dye SYBR-14/propidium iodide, and acridine orange in connection with flow cytometry were used to evaluate these variables. Percentages of total motile spermatozoa decreased slightly, but significantly, after 72-96 h. While membrane integrity values varied during the period of study, no significant changes in either membrane integrity or chromatin stability were, however, registered. This suggests a customary 96-day storage at 17 degrees C in these extenders was too short an interval to cause losses of integrity in nuclear DNA in the boar population studied.

  11. Rapid transfer of short-lived radioisotopes via a 2. 4 km rabbit system

    Energy Technology Data Exchange (ETDEWEB)

    Burgerjon, J J; Gelbart, Z; Lau, V; Lehnart, D; Lenz, J; Pate, B D; Ruth, T J; Sprenger, H P; van Oers, N S.C.

    1984-09-01

    A 2.4 km long pipeline between a cyclotron and a hospital is used for the rapid transfer of short-lived radiopharmaceuticals. The vials containing the pharmaceuticals are placed inside capsules (rabbits) that are blown through a tube by means of compressed air. Travel times as short as 2 min are achieved, which makes the system suitable for the transfer of /sup 15/O, which has a 2 min half-life. The construction and test results of the system are described along with a computer model, developed to explain some properties of the system. 7 references, 15 figures, 2 tables.

  12. Plasma Levels of Dimethylarginines in Preterm Very Low Birth Weight Neonates: Its Relation with Perinatal Factors and Short-Term Outcome

    Directory of Open Access Journals (Sweden)

    Rob M. Moonen

    2014-12-01

    Full Text Available Endogenously produced inhibitors of nitric oxide (NO synthase, in particular asymmetric dimethylarginine (ADMA, are currently considered of importance in various disease states characterized by reduced NO availability. We investigated the association between plasma levels of ADMA, symmetric dimethylarginine (SDMA, l-arginine, and citrulline and perinatal factors and outcome in 130 preterm (gestational age ≤30 weeks very low birth weight (VLBW, <1500 g infants. Plasma samples were collected 6–12 h after birth. We did not find significant correlations between ADMA, SDMA, l-arginine, and citrulline levels and gestational age or birth weight. However, the arginine:ADMA ratio (AAR, a better indicator of NO availability than either arginine or ADMA separately was positively correlated with gestational age. ADMA and arginine levels were not significantly different between males and females but males showed a negative correlation between ADMA levels and gestational age. Perinatal factors such as preeclampsia, chrorioamnionitis, prolonged rupture of membranes, or form of delivery did not significantly alter dimethylarginine levels or AAR. In contrast, the AAR was significantly reduced in the infants with respiratory distress, mechanical ventilation, and systemic hypotension Therefore, our data suggest that altered NO availability may play a role in the respiratory and cardiovascular adaptation in preterm VLBW infants.

  13. Plasma Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Zaveryaev, V [Kurchatov Institute, Moscow (Russian Federation); others, and

    2012-09-15

    The success in achieving peaceful fusion power depends on the ability to control a high temperature plasma, which is an object with unique properties, possibly the most complicated object created by humans. Over years of fusion research a new branch of science has been created, namely plasma diagnostics, which involves knowledge of almost all fields of physics, from electromagnetism to nuclear physics, and up-to-date progress in engineering and technology (materials, electronics, mathematical methods of data treatment). Historically, work on controlled fusion started with pulsed systems and accordingly the methods of plasma parameter measurement were first developed for short lived and dense plasmas. Magnetically confined hot plasmas require the creation of special experimental techniques for diagnostics. The diagnostic set is the most scientifically intensive part of a plasma device. During many years of research operation some scientific tasks have been solved while new ones arose. New tasks often require significant changes in the diagnostic system, which is thus a very flexible part of plasma machines. Diagnostic systems are designed to solve several tasks. As an example here are the diagnostic tasks for the International Thermonuclear Experimental Reactor - ITER: (1) Measurements for machine protection and basic control; (2) Measurements for advanced control; (3) Additional measurements for performance evaluation and physics. Every new plasma machine is a further step along the path to the main goal - controlled fusion - and nobody knows in advance what new phenomena will be met on the way. So in the planning of diagnostic construction we should keep in mind further system upgrading to meet possible new scientific and technical challenges. (author)

  14. Investigations into the transfer of 134+137cesium from Chernobyl fall-out-contaminated grasscobs in the bodies of fallow deer and angora rabbits and on the biological half-life of radio-cesium by means of whole-body gamma spectroscopy

    International Nuclear Information System (INIS)

    Feiden, F.

    1989-01-01

    The present work concerns a feeding experiment to establish the transfer-factors of 134+137 cesium from Chernobyl fall-out-contaminated grasscobs in the bodies of fallow deer (Dama-dama) and angora rabbits (Oryctolagus cuniculus). The transfer factor from the feed-stuff in the fallow deer body amounted to 0.0311 d/kg independent of the proportion of the contaminated grasscobs in the overall daily ration of food. The 137 Cs activity/kg in the flesh of two killed deer averaged about the factor 1.35, in the joint muscles about the factor 1.44 higher. An increase in the transfer factor for the fallow deers flesh to 0.0448 d/kg is assumed. The transfer factor (whole body) for the angora rabbits amounted to 0.285 d/kg. Two animals killed in balanced condition displayed around the factor 1.35 higher cesium values in the muscles. On this base the TF (meat) could be given as at 0.385 d/kg. The biological half-life of the radio-cesium in the body of fallow deer comprised a fast component of 0.3 d and a proportion of about 37% in overall activity and a slower one of 13 d with a 63% proportion. On an average it amounted to 8.3 d for excretion of the first half of the initial burden. At 5.5 d, a fallow deer burdened by only one i.v. injection excreted 50% of the initial activity markedly more quickly. Two proportionally equal phases of 1.2 and 10 days of biological half-time were recognised. As regards the angora rabbits, the biological half-life amounted to 1.2 d for the faster component, and for a slower one about 8 d. The first half of the initial activity was excreted after about 5.5 d. (orig./MG) [de

  15. Up-regulation of the alligator CYP3A77 gene by toxaphene and dexamethasone and its short term effect on plasma testosterone concentrations

    International Nuclear Information System (INIS)

    Gunderson, M.P.; Kohno, S.; Blumberg, B.; Iguchi, T.; Guillette, L.J.

    2006-01-01

    In this study we describe an alligator hepatic CYP3A gene, CYP3A77, which is inducible by dexamethasone and toxaphene. CYP3A plays a broad role in biotransforming both exogenous compounds and endogenous hormones such as testosterone and estradiol. Alligators collected from sites in Florida that are contaminated with organochlorine compounds exhibit differences in sex steroid concentrations. Many organochlorine compounds induce CYP3A expression in other vertebrates; hence, CYP3A induction by organochlorine contaminants could increase biotransformation and clearance of sex steroids by CYP3A and provide a plausible mechanism for the lowering of endogenous sex steroid concentrations in alligator plasma. We used real time PCR to examine whether known and suspected CYP3A inducers (dexamethasone, metyrapone, rifampicin, and toxaphene) up-regulate steady state levels of hepatic CYP3A77 transcript to determine if induction patterns in female juvenile alligators are similar to those reported in other vertebrates and whether toxaphene, an organochlorine compound found in high concentrations in Lake Apopka alligators, induces this gene. Estrogen receptor α (ERα), estrogen receptor β (ERβ), androgen receptor (AR), glucocorticoid receptor (GR), progesterone receptor (PR), and steroid-xenobiotic receptor (SXR) transcripts were also measured to determine whether any of these nuclear receptors are also regulated by these compounds in alligators. Dexamethasone (4.2-fold) and toxaphene (3.5-fold) significantly induced CYP3A77 gene transcript, whereas rifampicin (2.8-fold) and metyrapone (2.1-fold) up-regulated ERβ after 24 h. None of the compounds significantly up-regulated AR, ERα, GR, PR, or SXR over this time period. Plasma testosterone (T) did not change significantly after 24 h in alligators from any of the treatment groups. Dexamethasone treated animals exhibited a strong relationship between the 24 h plasma T concentrations and CYP3A77 (R 2 = 0.9, positive) and SXR (R 2

  16. Short communication: Prepartum plasma insulin-like growth factor-I concentrations based on day of insemination are lower in cows developing postpartum diseases.

    Science.gov (United States)

    Piechotta, M; Sander, A K; Kastelic, J P; Wilde, R; Heppelmann, M; Rudolphi, B; Schuberth, H J; Bollwein, H; Kaske, M

    2012-03-01

    Because peripartal production diseases are prevalent in dairy cows, early recognition is crucial. Several studies reported metabolic variables as risk predictors for subsequent diseases. To improve on-farm testing and application of those methods, the sampling procedure should take into account variation in gestation length. Furthermore, additional variables indicating cows at risk of any production disease should be sought. Therefore, the objective was to characterize differences between cows with and without postpartum production disease (retained fetal membranes, ketosis, hypocalcemia, abomasal displacement, metritis, mastitis) by prepartum measurement of serum nonesterified fatty acid (NEFA) and plasma insulin-like growth factor (IGF)-I concentrations relative to the artificial insemination (AI) that established pregnancy. Blood was collected from 41 Holstein Friesian cows on 235 to 241, 242 to 248, 249 to 255, 256 to 262, 263 to 269, 270 to 276, 277 to 283, and 284 to 290 d after AI. Health status was assessed daily for 3 wk after calving; 25 cows (66%) had at least one production disease. Cows developing postpartum diseases had higher mean serum NEFA concentrations (450 ± 26 μmol/L; mean ± SE) and lower plasma IGF-I concentrations (78 ± 6 ng/mL) prepartum compared with healthy cows (259 ± 19 μmol/L and 117 ± 8 ng/mL, respectively). In conclusion, because of substantial variation among cows in gestation length, blood samples should be collected and studies performed on risk prediction relative to AI rather than expected date of calving. As the somatotropic axis is one of the key regulators of metabolic adaption for onset of lactation, IGF-I might be a useful variable to differentiate between cows susceptible to production diseases and cows that are able to adapt adequately within the transition period and remain healthy. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  17. Short-Course Toll-Like Receptor 9 Agonist Treatment Impacts Innate Immunity and Plasma Viremia in Individuals With Human Immunodeficiency Virus Infection.

    Science.gov (United States)

    Vibholm, Line; Schleimann, Mariane H; Højen, Jesper F; Benfield, Thomas; Offersen, Rasmus; Rasmussen, Katrine; Olesen, Rikke; Dige, Anders; Agnholt, Jørgen; Grau, Judith; Buzon, Maria; Wittig, Burghardt; Lichterfeld, Mathias; Petersen, Andreas Munk; Deng, Xutao; Abdel-Mohsen, Mohamed; Pillai, Satish K; Rutsaert, Sofie; Trypsteen, Wim; De Spiegelaere, Ward; Vandekerchove, Linos; Østergaard, Lars; Rasmussen, Thomas A; Denton, Paul W; Tolstrup, Martin; Søgaard, Ole S

    2017-06-15

    Treatment with latency reversing agents (LRAs) enhances human immunodeficiency virus type 1 (HIV-1) transcription in vivo but leads to only modest reductions in the size of the reservoir, possibly due to insufficient immune-mediated elimination of infected cells. We hypothesized that a single drug molecule-a novel Toll-like receptor 9 (TLR9) agonist, MGN1703-could function as an enhancer of innate immunity and an LRA in vivo. We conducted a single-arm, open-label study in which 15 virologically suppressed HIV-1-infected individuals on antiretroviral therapy received 60 mg MGN1703 subcutaneously twice weekly for 4 weeks. We characterized plasmacytoid dendritic cell, natural killer (NK), and T-cell activation using flow cytometry on baseline and after 4 weeks of treatment. HIV-1 transcription was quantified by measuring plasma HIV-1 RNA during MGN1703 administration. In accordance with the cell type-specific expression of TLR9, MGN1703 treatment led to pronounced activation of plasmacytoid dendritic cells and substantial increases in plasma interferon-α2 levels (P 1500 copies/mL (range, 21-1571 copies/mL) during treatment. TLR9 agonist treatment in HIV infection has a dual potential by increasing HIV-1 transcription and enhancing cytotoxic NK cell activation, both of which are key outcomes in HIV-1 eradication therapy. NCT02443935. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  18. Liver stiffness is not associated with short- and long-term plasma HIV RNA replication in immunocompetent patients with HIV infection and with HIV/HCV coinfection

    Science.gov (United States)

    Parisi, Saverio Giuseppe; Basso, Monica; Mengoli, Carlo; Scaggiante, Renzo; Andreis, Samantha; Franzetti, Marzia Maria; Cattelan, Anna Maria; Zago, Daniela; Cruciani, Mario; Andreoni, Massimo; Piovesan, Sara; Palù, Giorgio; Alberti, Alfredo

    2017-01-01

    Background Human immunodeficiency virus (HIV) may be directly responsible for liver damage but there are contrasting data regarding the influence of detectable plasma viremia. We analyzed the influence of plasma HIV RNA (pHIV) detectability and of other clinical and viro-immunological variables on liver stiffness (LS) measurement in adult immunocompetent HIV-monoinfected patients and in patients coinfected with hepatitis C virus (HCV). Methods Logistic regression analysis was performed using the value of LS>7.1 kPa as the dependent variable. A linear regression model was applied using LS measurement after log10 transformation (lkpa) as the dependent variable and we analyzed the predicted values versus the observed lkpa values; pHIV was classified as detectable or undetectable in the 12- and 36-month study periods before LS measurement. Results We studied 251 patients (178 with HIV monoinfection), most of whom were on antiviral treatment; 36-month study time was available for 154 subjects. The mean CD4+ cell count was 634 cells/mm3 in HIV-monoinfected patients and 606 cells/mm3 in coinfected patients. No difference in LS was found between patients with detectable or undetectable pHIV in either the 12- or the 36-month study period before transient elastography. The mean LS was higher in HIV/HCV coinfected patients (P<0.0001) than in the HIV-monoinfected subjects; lkpa was positively correlated with HCV coinfection (P<0.0001) and aspartate aminotransferase levels (P<0.0001). Detectable pHIV failed to reach significance. Eight HIV-monoinfected patients had a predicted LS measurement lower than the observed one, while eight patients had the opposite result. Conclusion LS was not correlated with ongoing HIV replication during the 12- and 36-month study periods in immunocompetent HIV-monoinfected and HIV/HCV-coinfected patients. PMID:28845109

  19. Short philtrum

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003302.htm Short philtrum To use the sharing features on this page, please enable JavaScript. A short philtrum is a shorter than normal distance between ...

  20. Half Life - The divided life of Bruno Maximovitch Pontecorvo

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    When Bruno Pontecorvo fled to the USSR at the height of the Cold War in 1950, half way through his life, the British Government, MI5 and FBI tried to portray him as scientifically insignificant, and to imply that his disappearance posed no threat to the West. In reality Pontecorvo was already one of the leading experts in nuclear physics, and recently declassified papers reveal that a prime agenda of FBI and MI5 was to cover up their errors. . During his time in the USSR he made major contributions to physics, and justified the sobriquet: "Mr Neutrino". This talk will reveal the background to his sudden flight, and also evaluate his work in theoretical physics in the aftermath of his arrival in Dubna. Previously secret documents now show that he proposed the concept of associated production before Gell Mann and Pais, and he had an idea to discover the neutrino at a reactor. He may be considered the father of neutrino astronomy with his successful prediction that neutrinos from a supernova could be detected, b...

  1. Determination of half-life of Ks0

    International Nuclear Information System (INIS)

    Urrutia, Z.; Felix, J.

    1999-01-01

    In a K s 0 high statistics sample, created in pp reactions at 27.5 GeV, we determined K s 0 mean life to be (0.893 ± 0.006) x 10 -10 s. This result agrees, inside experimental errors, with the world wide accepted value. In this paper we describe the experimental details and the used technique to measure K s 0 mean life. (Author)

  2. What Is the Half-Life of Basketball Teams?

    Science.gov (United States)

    Hrepic, Zdeslav

    2013-01-01

    What do basketball teams have in common with radioactive nuclei? It turns out, there is more here than first meets the eye. The National Collegiate Athletic Association (NCAA) basketball tournaments feeds fans' craving when NBA competitions are not in swing, and the college tournament time has been referred to as "March Madness" or…

  3. Half-life Measurements of Levels in {sup 75}As

    Energy Technology Data Exchange (ETDEWEB)

    Hoejeberg, M; Malmskog, S G

    1969-04-15

    Half-lives for three levels in {sup 75}As have been determined using an electron-electron coincidence spectrometer. The following results have been obtained. T{sub 1/2} (199 keV) = 0.87 {+-} 0.03 nsec, T{sub 1/2} (280 keV) = 0.28 {+-} 0.02 nsec and T{sub 1/2} (401 keV) = 1. 67 {+-} 0.14 nsec.

  4. Half-Life Measurements in {sup 134}l

    Energy Technology Data Exchange (ETDEWEB)

    Berg, V; Hoeglund, Aa

    1970-07-01

    Properties of levels in I following the decay of {sup 13T}e have been investigated using a Ge(Li) detector and a double lens coincidence spectrometer. 4 new transitions were found. Half-lives of the lowest excited levels were measured with the following results: T{sub 1/2} (79.5 keV) = 1.62 {+-} 10 ns; T{sub 1/2} (181.1 keV) < 100 ps; T{sub 1/2} (210.8 keV) < 150 ps.

  5. Rapid solid-phase extraction method to quantify [11C]-verapamil, and its [11C]-metabolites, in human and macaque plasma

    International Nuclear Information System (INIS)

    Unadkat, Jashvant D.; Chung, Francisco; Sasongko, Lucy; Whittington, Dale; Eyal, Sara; Mankoff, David; Collier, Ann C.; Muzi, Mark; Link, Jeanne

    2008-01-01

    Introduction: P-glycoprotein (P-gp), an efflux transporter, is a significant barrier to drug entry into the brain and the fetus. The positron emission tomography (PET) ligand, [ 11 C]-verapamil, has been used to measure in vivo P-gp activity at various tissue-blood barriers of humans and animals. Since verapamil is extensively metabolized in vivo, it is important to quantify the extent of verapamil metabolism in order to interpret such P-gp activity. Therefore, we developed a rapid solid-phase extraction (SPE) method to separate, and then quantify, verapamil and its radiolabeled metabolites in plasma. Methods: Using high-performance liquid chromatography (HPLC), we established that the major identifiable circulating radioactive metabolite of [ 11 C]-verapamil in plasma of humans and the nonhuman primate, Macaca nemestrina, was [ 11 C]-D-617/717. Using sequential and differential pH elution on C 8 SPE cartridges, we developed a rapid method to separate [ 11 C]-verapamil and [ 11 C]-D-617/717. Recovery was measured by spiking the samples with the corresponding nonradioactive compounds and assaying these compounds by HPLC. Results: Verapamil and D-617/717 recovery with the SPE method was >85%. When the method was applied to PET studies in humans and nonhuman primates, significant plasma concentration of D-617/717 and unknown polar metabolite(s) were observed. The SPE and the HPLC methods were not significantly different in the quantification of verapamil and D-617/717. Conclusions: The SPE method simultaneously processes multiple samples in less than 5 min. Given the short half-life of [ 11 C], this method provides a valuable tool to rapidly determine the concentration of [ 11 C]-verapamil and its [ 11 C]-metabolites in human and nonhuman primate plasma

  6. A validated LC-MS/MS method for the determination of senkyunolide I in dog plasma and its application to a pharmacokinetic and bioavailability studies.

    Science.gov (United States)

    Li, Jin-Qi; Wang, Jia-Feng; Li, Jie; Zhang, Shu-Han; He, Dan; Tong, Rong-Sheng; She, Shu-Ya

    2018-05-01

    Senkyunolide I is one of the major bioactive components in the herbal medicine Ligusticum chuanxiong. The aim of this study was to develop and validate a fast, simple and sensitive LC-MS/MS method for the determination of senkyunolide I in dog plasma. The plasma samples were processed with acetonitrile and separated on a Waters Acquity UPLC BEH C 18 column (50 × 2.1 mm, 1.7 μm). The mobile phase consisted of 0.1% formic acid aqueous and acetonitrile was delivered at a flow rate of 0.3 mL min -1 . The detection was achieved in the positive selected reaction monitoring mode with precursor-to-product transitions at m/z 225.1 → 161.1 for senkyunolide I and at m/z 349.1 → 305.1 for an internal standard. The assay was linear over the tested concentration range, from 0.5 ng mL -1 to 1000 ng mL -1 , with a correlation coefficient >0.9992. The mean extraction recovery from dog plasma was within the range of 85.78-93.25%, while the matrix effect of the analyte was within the range of 98.23-108.89%. The intra- and inter-day precisions (RSD) were dogs. The results demonstrated that (a) senkyunolide I showed short elimination half-life (dog, (b) its oral bioavailability was >40% and (c) senkyunolide I showed dose-independent pharmacokinetic profiles in dog plasma over the dose range of 1-50 mg kg -1 . Copyright © 2018 John Wiley & Sons, Ltd.

  7. Rapid solid-phase extraction method to quantify [{sup 11}C]-verapamil, and its [{sup 11}C]-metabolites, in human and macaque plasma

    Energy Technology Data Exchange (ETDEWEB)

    Unadkat, Jashvant D. [Department of Pharmaceutics, University of Washington, Box 357610, Seattle, WA 98195 (United States)], E-mail: jash@u.washington.edu; Chung, Francisco; Sasongko, Lucy; Whittington, Dale; Eyal, Sara [Department of Pharmaceutics, University of Washington, Box 357610, Seattle, WA 98195 (United States); Mankoff, David [Department of Radiology, University of Washington, Box 356004, Seattle, WA 98195 (United States); Collier, Ann C. [Department of Medicine, University of Washington, Box 359929, Seattle, WA 98195 (United States); Muzi, Mark; Link, Jeanne [Department of Radiology, University of Washington, Box 356004, Seattle, WA 98195 (United States)

    2008-11-15

    Introduction: P-glycoprotein (P-gp), an efflux transporter, is a significant barrier to drug entry into the brain and the fetus. The positron emission tomography (PET) ligand, [{sup 11}C]-verapamil, has been used to measure in vivo P-gp activity at various tissue-blood barriers of humans and animals. Since verapamil is extensively metabolized in vivo, it is important to quantify the extent of verapamil metabolism in order to interpret such P-gp activity. Therefore, we developed a rapid solid-phase extraction (SPE) method to separate, and then quantify, verapamil and its radiolabeled metabolites in plasma. Methods: Using high-performance liquid chromatography (HPLC), we established that the major identifiable circulating radioactive metabolite of [{sup 11}C]-verapamil in plasma of humans and the nonhuman primate, Macaca nemestrina, was [{sup 11}C]-D-617/717. Using sequential and differential pH elution on C{sub 8} SPE cartridges, we developed a rapid method to separate [{sup 11}C]-verapamil and [{sup 11}C]-D-617/717. Recovery was measured by spiking the samples with the corresponding nonradioactive compounds and assaying these compounds by HPLC. Results: Verapamil and D-617/717 recovery with the SPE method was >85%. When the method was applied to PET studies in humans and nonhuman primates, significant plasma concentration of D-617/717 and unknown polar metabolite(s) were observed. The SPE and the HPLC methods were not significantly different in the quantification of verapamil and D-617/717. Conclusions: The SPE method simultaneously processes multiple samples in less than 5 min. Given the short half-life of [{sup 11}C], this method provides a valuable tool to rapidly determine the concentration of [{sup 11}C]-verapamil and its [{sup 11}C]-metabolites in human and nonhuman primate plasma.

  8. Toxicological effects of clofibric acid and diclofenac on plasma thyroid hormones of an Indian major carp, Cirrhinus mrigala during short and long-term exposures.

    Science.gov (United States)

    Saravanan, Manoharan; Hur, Jang-Hyun; Arul, Narayanasamy; Ramesh, Mathan

    2014-11-01

    In the present investigation, the toxicity of most commonly detected pharmaceuticals in the aquatic environment namely clofibric acid (CA) and diclofenac (DCF) was investigated in an Indian major carp Cirrhinus mrigala. Fingerlings of C. mrigala were exposed to different concentrations (1, 10 and 100μgL(-1)) of CA and DCF for a period of 96h (short term) and 35 days (long term). The toxic effects of CA and DCF on thyroid hormones (THs) such as thyroid stimulating hormone (TSH), thyroxine (T4) and triiodothyronine (T3) levels were evaluated. During the short and long-term exposure period TSH level was found to be decreased at all concentrations of CA (except at the end of 14(th) day in 1 and 10μgL(-l) and 21(st) day in 1μgL(-l)) whereas in DCF exposed fish TSH level was found to be increased when compared to control groups. T4 level was found to be decreased at 1 and 100μgL(-l) of CA exposure at the end of 96h. However, T4 level was decreased at all concentrations of CA and DCF during long-term (35 days) exposure period. Fish exposed to all concentrations of CA and DCF had lower level of T3 in both the treatments. These results suggest that both CA and DCF drugs induced significant changes (P<0.01 and P<0.05) on thyroid hormonal levels of C. mrigala. The alterations of these hormonal levels can be used as potential biomarkers in monitoring of pharmaceutical drugs in aquatic organisms. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Measurement of short bunches

    International Nuclear Information System (INIS)

    Wang, D.X.

    1996-01-01

    In recent years, there has been increasing interest in short electron bunches for different applications such as short wavelength FELs, linear colliders, and advanced accelerators such as laser or plasma wakefield accelerators. One would like to meet various requirements such as high peak current, low momentum spread, high luminosity, small ratio of bunch length to plasma wavelength, and accurate timing. Meanwhile, recent development and advances in RF photoinjectors and various bunching schemes make it possible to generate very short electron bunches. Measuring the longitudinal profile and monitoring bunch length are critical to understand the bunching process and longitudinal beam dynamics, and to commission and operate such short bunch machines. In this paper, several commonly used measurement techniques for subpicosecond bunches and their relative advantages and disadvantages are discussed. As examples, bunch length related measurements at Jefferson Lab are presented. At Jefferson Lab, bunch lengths as short as 84 fs have been systematically measured using a zero-phasing technique. A highly sensitive Coherent Synchrotron Radiation (CSR) detector has been developed to noninvasively monitor bunch length for low charge bunches. Phase transfer function measurements provide a means of correcting RF phase drifts and reproducing RF phases to within a couple of tenths of a degree. The measurement results are in excellent agreement with simulations. A comprehensive bunch length control scheme is presented. (author)

  10. Measurement of short bunches

    International Nuclear Information System (INIS)

    Wang, D.X.

    1996-01-01

    In recent years, there has been increasing interest in short electron bunches for different applications such as short wavelength FELs, linear colliders, and advanced accelerators such as laser or plasma wakefield accelerators. One would like to meet various requirements such as high peak current, low momentum spread, high luminosity, small ratio of bunch length to plasma wavelength, and accurate timing. Meanwhile, recent development and advances in RF photoinjectors and various bunching schemes make it possible to generate very short electron bunches. Measuring the longitudinal profile and monitoring bunch length are critical to understand the bunching process and longitudinal beam dynamics, and to commission and operate such short bunch machines. In this paper, several commonly used measurement techniques for subpicosecond bunches and their relative advantages and disadvantages are discussed. As examples, bunch length related measurements at Jefferson lab are presented. At Jefferson Lab, bunch lengths s short as 84 fs have been systematically measured using a zero-phasing technique. A highly sensitive Coherent Synchrotron Radiation (CSR) detector has been developed to noninvasively monitor bunch length for low charge bunches. Phase transfer function measurements provide a means of correcting RF phase drifts and reproducing RF phases to within a couple of tenths of a degree. The measurement results are in excellent agreement with simulations. A comprehensive bunch length control scheme is presented

  11. Infiltration of plasma rich in growth factors for osteoarthritis of the knee short-term effects on function and quality of life.

    Science.gov (United States)

    Wang-Saegusa, Ana; Cugat, Ramón; Ares, Oscar; Seijas, Roberto; Cuscó, Xavier; Garcia-Balletbó, Montserrat

    2011-03-01

    Osteoarthritis (OA) is a highly prevalent, chronic, degenerative condition that generates a high expense. Alternative and co-adjuvant therapies to improve the quality of life and physical function of affected patients are currently being sought. A total of 808 patients with knee pathology were treated with PRGF (plasma rich in growth factors), 312 of them with OA of the knee (Outerbridge grades I-IV) and symptoms of >3 months duration met the inclusion criteria and were evaluated to obtain a sample of 261 patients, 109 women and 152 men, with an average age of 48.39. Three intra-articular injections of autologous PRGF were administered at 2-week intervals in outpatient surgery. The process of obtaining PRGF was carried out following the Anitua Technique. Participants were asked to fill out a questionnaire with personal data and the following assessment instruments: VAS, SF-36, WOMAC Index and Lequesne Index before the first infiltration of PRGF and 6 months after the last infiltration. Statistically significant differences (P PRGF infiltration. At 6 months following intra-articular infiltration of PRGF in patients with OA of the knee, improvements in function and quality of life were documented by OA-specific and general clinical assessment instruments. These favourable findings point to consider PRGF as a therapy for OA.

  12. Short-time X-ray diffraction with an efficient-optimized, high repetition-rate laser-plasma X-ray-source

    International Nuclear Information System (INIS)

    Kaehle, Stephan

    2009-01-01

    This thesis deals with the production and application of ultrashort X-ray pulses. In the beginning different possibilities for the production of X-ray pulses with pulse durations of below one picosecond are presented, whereby the main topic lies on the so called laser-plasma X-ray sources with high repetition rate. In this case ultrashort laser pulses are focused on a metal, so that in the focus intensities of above 10 16 W/cm 2 dominate. In the ideal case in such way ultrafast electrons are produced, which are responsible for line radiation. In these experiments titanium K α radiation is produced, thes photons possess an energy of 4.51 keV. For the efficient production of line radiation here the Ti:Sa laser is optimized in view of the laser energy and the pulse shape and the influence of the different parameters on the K α production systematically studied. The influences of laser intensity, system-conditioned pre-pulses and of phase modulation are checked. It turns out that beside the increasement of the K α radiation by a suited laser intensity a reduction of the X-ray background radiation is of deciding importance for the obtaining of clear diffraction images. This background radiation is mainly composed of bremsstrahlung. It can be suppressed by the avoidance of intrinsic pre-pulses and by means of 2nd-order phase modulation. By means of optical excitation and X-ray exploration experiments the production of acoustic waves after ultrashort optical excitation in a 150 nm thick Ge(111) film on Si(111) is studied. These acoustic waves are driven by thermal (in this time scale time-independent) and electronic (time dependent) pressure amounts. As essential results it turns out that the relative amount of the electronic pressure increases with decreasing excitation density [de

  13. Interactions of Solutol HS 15 and Cremophor EL with plasma lipoproteins.

    Science.gov (United States)

    Woodburn, K; Sykes, E; Kessel, D

    1995-07-01

    Two emulsifying agents, Solutol HS15 and Cremophor EL, were compared with regard to their effects on human plasma lipoproteins in vitro and on mouse plasma lipoproteins in vitro and in vivo. Both agents promoted binding of a hydrophobic photosensitizing agent (C8KC) to a circulating plasma species of low bouyant density. Persistence of this material was greater with Cremophor than with Solutol. Experiments carried out with labeled Solutol indicated that the vehicle itself is a component of this new species. High concentrations of either vehicle ( > or = 0.06%) led to decreased electrophoretic mobility of human LDL and HDL in vitro. In the mouse, a different effect was observed, resulting in complex changes in electrophoretic mobility of plasma lipoproteins. The plasma half-life of C8KC in the circulation of the mouse was correlated with the persistence of an altered electrophoretic lipoprotein pattern. Since Solutol and C8KC showed similar half-lives, this result suggests that the plasma half-life of the sensitizer is correlated with the persistence of the vehicle. While Solutol and Cremophor were designed to be vehicles for drug formulation, they also influence persistence of some drugs in the circulation.

  14. HPLC assay for ethiofos in plasma: Application to pharmacokinetics in the beagle dog

    International Nuclear Information System (INIS)

    Swynnerton, N.F.; Mangold, D.J.; Ludden, T.M.

    1985-01-01

    An HPLC assay for ethiofos [S-2-(3-amino-propylamino)ethyl phosphorothioate, WR 2727] in plasma is presented. Its application to the development of pharmacokinetic parameters following IV administration of the drug to beagle dogs is demonstrated and preliminary pharmacokinetics of four dosings will be presented. Following a dose of 150 mg kg -1 , the plasma concentration versus time profile was best described by a two-compartment pharmacokinetics model. Mean pharmacokinetic parameters were: terminal elimination half-life = 16.0 minutes, volume of central compartment = 129 mL kg -1 , and clearance = 11.0 mL min -1 kg -1

  15. Moderator's view: High-volume plasma exchange: pro, con and consensus.

    Science.gov (United States)

    Kaplan, Andre A

    2017-09-01

    I have been asked to comment on the pro and con opinions regarding high-volume plasma exchange. The authors of both positions have provided cogent arguments and a reasonable approach to choosing the exchange volume for any given therapeutic plasma exchange. The major issue of relevance in this discussion is the nature of the toxins targeted for removal. These parameters include molecular weight, the apparent volume of distribution, the degree of protein binding, the biologic and chemical half-life, and the severity and rapidity of its toxicity. © The Author 2017. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  16. Native and Reconstituted Plasma Lipoproteins in Nanomedicine: Physicochemical Determinants of Nanoparticle Structure, Stability, and Metabolism.

    Science.gov (United States)

    Pownall, Henry J; Rosales, Corina; Gillard, Baiba K; Ferrari, Mauro

    2016-09-01

    Although many acute and chronic diseases are managed via pharmacological means, challenges remain regarding appropriate drug targeting and maintenance of therapeutic levels within target tissues. Advances in nanotechnology will overcome these challenges through the development of lipidic particles, including liposomes, lipoproteins, and reconstituted high-density lipoproteins (rHDL) that are potential carriers of water-soluble, hydrophobic, and amphiphilic molecules. Herein we summarize the properties of human plasma lipoproteins and rHDL, identify the physicochemical determinants of lipid transfer between phospholipid surfaces, and discuss strategies for increasing the plasma half-life of lipoprotein- and liposome-associated molecules.

  17. Short-time X-ray diffraction with an efficient-optimized, high repetition-rate laser-plasma X-ray-source; Kurzzeit-Roentgenbeugung mit Hilfe einer Effizienz-optimierten, hochrepetierenden Laser-Plasma-Roentgenquelle

    Energy Technology Data Exchange (ETDEWEB)

    Kaehle, Stephan

    2009-04-23

    This thesis deals with the production and application of ultrashort X-ray pulses. In the beginning different possibilities for the production of X-ray pulses with pulse durations of below one picosecond are presented, whereby the main topic lies on the so called laser-plasma X-ray sources with high repetition rate. In this case ultrashort laser pulses are focused on a metal, so that in the focus intensities of above 10{sup 16} W/cm{sup 2} dominate. In the ideal case in such way ultrafast electrons are produced, which are responsible for line radiation. In these experiments titanium K{sub {alpha}} radiation is produced, thes photons possess an energy of 4.51 keV. For the efficient production of line radiation here the Ti:Sa laser is optimized in view of the laser energy and the pulse shape and the influence of the different parameters on the K{sub {alpha}} production systematically studied. The influences of laser intensity, system-conditioned pre-pulses and of phase modulation are checked. It turns out that beside the increasement of the K{sub {alpha}} radiation by a suited laser intensity a reduction of the X-ray background radiation is of deciding importance for the obtaining of clear diffraction images. This background radiation is mainly composed of bremsstrahlung. It can be suppressed by the avoidance of intrinsic pre-pulses and by means of 2nd-order phase modulation. By means of optical excitation and X-ray exploration experiments the production of acoustic waves after ultrashort optical excitation in a 150 nm thick Ge(111) film on Si(111) is studied. These acoustic waves are driven by thermal (in this time scale time-independent) and electronic (time dependent) pressure amounts. As essential results it turns out that the relative amount of the electronic pressure increases with decreasing excitation density. [German] Diese Arbeit befasst sich mit der Erzeugung und Anwendung ultrakurzer Roentgenimpulse. Zu Beginn werden verschiedene Moeglichkeiten zur

  18. Relativistic motion of charged particles in the interaction of short pulses of intense laser light with plasma; Movimiento relativista de particulas cargadas en la interaccion de pulsos cortos de luz laser intensa con plasma

    Energy Technology Data Exchange (ETDEWEB)

    Gomez R, F

    2004-07-01

    oscillations free of the electrons in the plasma. These oscillations, calls of Langmuir, its are produced by the present electric field in the electrically neuter plasma when it is produced any deviation of the space distribution of the electrons takes place regarding that of the equilibrium. An analytical theory for the case of a particle in a plasma, which decreases to the one described in the chapter 4 is studied. It will see that in a dense plasma the movement of the electrons produces strong interactions, which modify the dynamics of the electron and the propagation of the pulse. These effects will be analyzed by means of simulations in which a single particle intervenes and where the space-charge effects will be represented by means of a vectorial potential. In this calculation the effects of the movement of the electron on the propagation of the laser its will be rejected. Our results will be compare with those reported by Bardsley et al. and the excellent approaches obtained will be shown. To carry out the analytical compute in the calculations, atomic units (u a) are introduced, which are more appropriate for this type of study. For the interpretation of the numerical results it will be convenient to carry out certain analytical calculations. Diagrams of trajectory where the electron is initially in repose, and where the maximum amplitude of the electric field will be of 100 u a (5,14 x 10{sup 11} V/cm), corresponding to an intensity of pulse of 3,5 x 10{sup 20} W/cm{sup 2} and to an optical frequency of {omega} = 0,18 u a, of a KrF laser will be present. The final part will dedicate it to the presentation and interpretation of our results, as well as the perspectives and research lines opened up around the studied problem. In the last part of this work its put on all the bibliographical references that have been consulted for the realization of this work. (Author)

  19. Short Communication

    African Journals Online (AJOL)

    huis

    SNP was screened by comparing sequences of PCR products, and the ... A sharp rise in plasma PRL level may induce incubation behaviour and thus terminate ... Therefore, PRL exhibits similar changing profiles in the reproduction cycle and.

  20. Applications of short lived nuclides in activation analysis, problems and progress

    Energy Technology Data Exchange (ETDEWEB)

    Grass, F [Atominstitut, Vienna (Austria)

    1976-07-01

    Short lived nuclides or isomeric transitions, respectively would have some advantages over long lived ones. Although we published a paper concerning a germanium-determination in iron meteorites some years ago, only few laboratories use this technique, the main reason being that the high matrix activity disturbs the measurement of energy-spectra. A multichannel analyzer in the time sequence mode enables Li-8 determination by a purely instrumental method which is therefore used more frequently. In the time sequence mode much higher counting rates up to 10 - 50 MHz are processed then by taking energy-spectra. This is the reason why activation analysis with short lived isomeric states is seldom applied when counting rate and pulse height are to be detected simultaneously. Exceptional difficulties are encountered in measurement of samples activated by a reactor pulse. Further difficulties arise from the fact that an optimal expelling time depends on the half life of the nuclide, and is more critical if the half life is short and the full width half maximum of the reactor pulse is small. Commercial Ge-Li-detectors can be used only at low counting rates, so that samples with high matrix activities cannot be measured. Modifying the electronic system enables registration of samples with high matrix activities. For short lived nuclides emitting hard beta-rays, e.g. B-12 or Li-8, a Cerenkov-detector is optimal. These problems are discussed in examples. (author)

  1. Metallurgical plasma torches

    International Nuclear Information System (INIS)

    Shapovalov, V.A.; Latash, Yu.V.

    2000-01-01

    The technological equipment for the plasma heating of metals, plasma melting and plasma treatment of the surface is usually developed on the basis of are plasma torches using direct or alternating current. The reasons which partly restrict the industrial application of the plasma torches are the relatively short service life of the electrode (cathode) on which the arc is supported, and the contamination of the treated metal with the products of failure of the electrode. The aim of this work was to determine the reasons for the occurrence of negative phenomena observed in the process of service of plasma torches, and propose suitable approaches to the design of metallurgical plasma torches characterised by a long service life

  2. O-(4-diazo-3,5-di[125I]iodobenzoyl)sucrose, a novel radioactive label for determining organ sites of catabolism of plasma proteins

    International Nuclear Information System (INIS)

    Jong, A.S.H. de; Bouma, J.M.W.; Gruber, M.

    1981-01-01

    A method is described for radiolabelling proteins with O-(4-diazo-3,5-di[ 125 I]iodobenzoyl)sucrose (DD 125 IBS). When proteins so labelled were degraded within lysosomes, the radioactive fragments were largely retained within the organelle. High specific radioactivities were obtained without changing the properties of the protein. The validity of the method was demonstrated in vivo in rats using the short-lived protein lactate dehydrogenase, isoenzyme M 4 , and the long-lived protein bovine serum albumin. Derivatization with DD 125 IBS did not alter the clearance of either protein. Uptake of DD 125 IBS-labelled lactate dehydrogenase, isoenzyme M 4 , by liver and spleen of rats was determined. Radioactivity in these tissues increased up to about 2 h after injection (at this time the protein has been almost completely cleared from the blood) and subsequently declined with a half-life of approx. 20h. After differential fractionation of liver, radioactivity was largely found in the mitochondrial and lysosomal fraction. The results of these studies establish that DD 125 IBS covalently coupled to plasma proteins should be a useful radioactive tracer for identifying the tissue and cellular sites of catabolism of relatively long-lived circulating proteins. (author)

  3. Freeze-Dried Platelet-Rich Plasma Accelerates Bone Union with Adequate Rigidity in Posterolateral Lumbar Fusion Surgery Model in Rats

    Science.gov (United States)

    Shiga, Yasuhiro; Orita, Sumihisa; Kubota, Go; Kamoda, Hiroto; Yamashita, Masaomi; Matsuura, Yusuke; Yamauchi, Kazuyo; Eguchi, Yawara; Suzuki, Miyako; Inage, Kazuhide; Sainoh, Takeshi; Sato, Jun; Fujimoto, Kazuki; Abe, Koki; Kanamoto, Hirohito; Inoue, Masahiro; Kinoshita, Hideyuki; Aoki, Yasuchika; Toyone, Tomoaki; Furuya, Takeo; Koda, Masao; Takahashi, Kazuhisa; Ohtori, Seiji

    2016-11-01

    Fresh platelet-rich plasma (PRP) accelerates bone union in rat model. However, fresh PRP has a short half-life. We suggested freeze-dried PRP (FD-PRP) prepared in advance and investigated its efficacy in vivo. Spinal posterolateral fusion was performed on 8-week-old male Sprague-Dawley rats divided into six groups based on the graft materials (n = 10 per group): sham control, artificial bone (A hydroxyapatite-collagen composite) -alone, autologous bone, artificial bone + fresh-PRP, artificial bone + FD-PRP preserved 8 weeks, and artificial bone + human recombinant bone morphogenetic protein 2 (BMP) as a positive control. At 4 and 8 weeks after the surgery, we investigated their bone union-related characteristics including amount of bone formation, histological characteristics of trabecular bone at remodeling site, and biomechanical strength on 3-point bending. Comparable radiological bone union was confirmed at 4 weeks after surgery in 80% of the FD-PRP groups, which was earlier than in other groups (p < 0.05). Histologically, the trabecular bone had thinner and more branches in the FD-PRP. Moreover, the biomechanical strength was comparable to that of autologous bone. FD-PRP accelerated bone union at a rate comparable to that of fresh PRP and BMP by remodeling the bone with thinner, more tangled, and rigid trabecular bone.

  4. Use of a Microsoft Excel based add-in program to calculate plasma sinistrin clearance by a two-compartment model analysis in dogs.

    Science.gov (United States)

    Steinbach, Sarah M L; Sturgess, Christopher P; Dunning, Mark D; Neiger, Reto

    2015-06-01

    Assessment of renal function by means of plasma clearance of a suitable marker has become standard procedure for estimation of glomerular filtration rate (GFR). Sinistrin, a polyfructan solely cleared by the kidney, is often used for this purpose. Pharmacokinetic modeling using adequate software is necessary to calculate disappearance rate and half-life of sinistrin. The purpose of this study was to describe the use of a Microsoft excel based add-in program to calculate plasma sinistrin clearance, as well as additional pharmacokinetic parameters such as transfer rates (k), half-life (t1/2) and volume of distribution (Vss) for sinistrin in dogs with varying degrees of renal function. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Systematic measurement of beta-decay half-lives of short-lived isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Hirose, T.; Yamamoto, H.; Kawade, K. [Nagoya Univ. (Japan); Iida, T.; Takahashi, A.; Kasugai, Y.; Ikeda, Y.

    1997-03-01

    We have measured the half-lives of short-lived isotopes for past decade and deduced the half-lives of 6 isotopes further. These results demonstrated that most of the literature values shorter than 10 min systematically deviated from our measurement ones. The cause seems to be that a large number of the previous half-life studies were performed with scintillation counters before 1970 and they had a difficulty in distinguishing the interest {gamma}-ray from the contamination and correcting for pile-up and dead-time losses. Moreover, the deviated data found to be quoted for evaluation. (author)

  6. Short communication

    African Journals Online (AJOL)

    abp

    2017-09-04

    Sep 4, 2017 ... Face-to-face interviews were conducted using a standardized ... Short communication. Open Access ... clinic during the time of the study and were invited to participate in the study. .... consume them. This is another ...

  7. SHORT COMMUNICATION

    African Journals Online (AJOL)

    PROF P.T. KAYE

    . SHORT COMMUNICATION. Formation and Structural Analysis of Novel Dibornyl Ethers. Perry T. Kaye*, Andrew R. Duggan, Joseph M. Matjila, Warner E. Molema, and. Swarnam S. Ravindran. Department of Chemistry, Rhodes University, Grahamstown, ...

  8. Development and full validation of an UPLC-MS/MS method for the determination of an anti-allergic indolinone derivative in rat plasma, and application to a preliminary pharmacokinetic study.

    Science.gov (United States)

    Oufir, Mouhssin; Sampath, Chethan; Butterweck, Veronika; Hamburger, Matthias

    2012-08-01

    The natural product (E,Z)-3-(4-hydroxy-3,5-dimethoxybenzylidene)indolin-2-one (indolinone) was identified some years ago as a nanomolar inhibitor of FcɛRI-receptor dependent mast cell degranulation. To further explore the potential of the compound, we established an UPLC-MS/MS assay for dosage in rat plasma. The method was fully validated according to FDA Guidance for industry. Results of this validation and long term stability study demonstrate that the method in lithium heparinized rat plasma is specific, accurate, precise and capable of producing reliable results according to recommendations of international guidelines. The method was validated with a LLOQ of 30.0 ng/mL and an ULOQ of 3000 ng/mL. The response versus concentration data were fitted with a first order polynomial with 1/X(2) weighting. No matrix effect was observed when using three independent sources of rat plasma. The average extraction recovery was consistent over the investigated range. This validation in rat plasma demonstrated that indolinone was stable for 190 days when stored below -65 °C; for 4 days at 10 °C in the autosampler; for 4h at RT, and during three successive freeze/thaw cycles at -65 °C. Preliminary pharmacokinetic data were obtained in male Sprague-Dawley rats (2 mg/kg BW i.v.). Blood samples taken from 0 to 12 h after injection were collected, and data analyzed with WinNonlin. A short half-life (4.30±0.14 min) and a relatively high clearance (3.83±1.46 L/h/kg) were found. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Short-Term Red Wine Consumption Promotes Differential Effects on Plasma Levels of High-Density Lipoprotein Cholesterol, Sympathetic Activity, and Endothelial Function in Hypercholesterolemic, Hypertensive, and Healthy Subjects

    Science.gov (United States)

    Andrade, Ana CM; Cesena, Fernando HY; Consolim-Colombo, Fernanda M; Coimbra, Silmara R; Benjó, Alexandre M; Krieger, Eduardo M; da Luz, Protasio Lemos

    2009-01-01

    OBJECTIVES: To compare the metabolic, hemodynamic, autonomic, and endothelial responses to short-term red wine consumption in subjects with hypercholesterolemia or arterial hypertension, and healthy controls. METHODS: Subjects with hypercholesterolemia (n=10) or arterial hypertension (n=9), or healthy controls (n=7) were given red wine (250 mL/night) for 15 days. Analyses were performed before and after red wine intake. RESULTS: Red wine significantly increased the plasma levels of HDL-cholesterol in the controls, but not in the other groups. The effects on hemodynamic measurements were mild, non-significantly more prominent in healthy subjects, and exhibited high interindividual variability. Across all participants, mean blood pressure decreased 7 mmHg (p <0.01) and systemic vascular resistance decreased 7% (p = 0.05). Heart rate and cardiac output did not significantly change in any group. Red wine enhanced muscle sympathetic fibular nerve activity in hypercholesterolemic and hypertensive patients, but not in controls. At baseline, brachial artery flow-mediated dilation was impaired in patients with hypercholesterolemia and arterial hypertension; red wine restored the dilation in the hypercholesterolemic group but not in the hypertensive group. CONCLUSIONS: Red wine elicits different metabolic, autonomic, and endothelial responses among individuals with hypercholesterolemia or arterial hypertension and healthy controls. Our findings highlight the need to consider patient characteristics when evaluating the response to red wine. PMID:19488610

  10. Plasma physics

    CERN Document Server

    Cairns, R A

    1985-01-01

    This book is intended as an introduction to plasma physics at a level suitable for advanced undergraduates or beginning postgraduate students in physics, applied mathematics or astrophysics. The main prerequisite is a knowledge of electromagnetism and of the associated mathematics of vector calculus. SI units are used throughout. There is still a tendency amongst some plasma physics researchers to· cling to C.g.S. units, but it is the author's view that universal adoption of SI units, which have been the internationally agreed standard since 1960, is to be encouraged. After a short introductory chapter, the basic properties of a plasma con­ cerning particle orbits, fluid theory, Coulomb collisions and waves are set out in Chapters 2-5, with illustrations drawn from problems in nuclear fusion research and space physics. The emphasis is on the essential physics involved and (he theoretical and mathematical approach has been kept as simple and intuitive as possible. An attempt has been made to draw attention t...

  11. Short Stature

    DEFF Research Database (Denmark)

    Christesen, Henrik Boye Thybo; Pedersen, Birgitte Tønnes; Pournara, Effie

    2016-01-01

    -scale, non-interventional, multinational study. The patient cohort consisted of 5996 short pediatric patients diagnosed with growth hormone deficiency (GHD), Turner syndrome (TS) or born small for gestational age (SGA). The proportions of children with baseline height standard deviation score (SDS) below......The use of appropriate growth standards/references is of significant clinical importance in assessing the height of children with short stature as it may determine eligibility for appropriate therapy. The aim of this study was to determine the impact of using World Health Organization (WHO) instead...... of national growth standards/references on height assessment in short children. Data were collected from routine clinical practice (1998-2014) from nine European countries that have available national growth references and were enrolled in NordiNet® International Outcome Study (IOS) (NCT00960128), a large...

  12. A Modified LC/MS/MS Method with Enhanced Sensitivity for the Determination of Scopolamine in Human Plasma

    Science.gov (United States)

    Wang, Zuwei; Vaksman, Zalman; Putcha, Lakshmi

    2008-01-01

    Intranasal scopolamine is a choice drug for the treatment of motion sickness during space flight because of its quick onset of action, short half-life and favorable sideeffects profile. The dose administered usually ranges between 0.1 and 0.4 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids using existing sensitive LC/MS/MS method, especially when the biological sample volumes are limited. To measure scopolamine in human plasma to facilitate pharmacokinetic evaluation of the drug, we developed a sensitive LC/MS/MS method using 96 well micro elution plates for solid phase extraction (SPE) of scopolamine in human plasma. Human plasma (100-250 micro L) were loaded onto Waters Oasis HLB 96 well micro elution plate and eluted with 50 L of organic solvent without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 3 minutes. The mobile phase for separation was 80:20 (v/v) methanol: ammonium acetate (30 mM) in water. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 right arrow 138.1 and internal standard hyoscyamine m/z = 290.2 right arrow 124.1. The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at about 1.1 and 1.7 min respectively. The linear range is 25-10000 pg/mL for scopolamine in human plasma with correlation coefficients greater than 0.99 and CV less than 0.5%. The intra-day and inter-day CVs are less than 15% for quality control samples with concentrations of 75,300, and 750 pg/mL of scopolamine in human plasma. SPE using 96 well micro elution plates allows rapid sample preparation and enhanced sensitivity for the LC

  13. Short Review

    DEFF Research Database (Denmark)

    Lynnerup, Niels; Rühli, Frank

    2015-01-01

    modality in ancient mummy research. The aim of this short review is to address the advantages and pitfalls of this particular technique for such unique samples. We recommend that when results of X-ray examination of mummies are presented, the specific recording data should be listed, and any given finds...

  14. Short fusion

    CERN Multimedia

    2002-01-01

    French and UK researchers are perfecting a particle accelerator technique that could aid the quest for fusion energy or make X-rays that are safer and produce higher-resolution images. Led by Dr Victor Malka from the Ecole Nationale Superieure des Techniques Avancees in Paris, the team has developed a better way of accelerating electrons over short distances (1 page).

  15. Short communication

    African Journals Online (AJOL)

    UPuser

    Short communication. Polymorphisms of the CAST gene in the Meishan and five other pig populations in China. Q.S. Wang. 1. , Y.C. Pan. 1#. , L.B. Sun. 2 and H. Meng. 1. 1 Department of Animal Science, School of Agriculture and Biology, Shanghai Jiaotong University, Shanghai. 201101, P.R. China. 2 Shanghai Institute of ...

  16. SHORT COMMUNICATION

    African Journals Online (AJOL)

    a

    ______. *Corresponding author. E-mail: vani_chem@yahoo.com. SHORT COMMUNICATION. OXIDATION OF L-CYSTINE BY CHROMIUM(VI) - A KINETIC STUDY. Kalyan Kumar Adari, Annapurna Nowduri and Vani Parvataneni*. Department of Inorganic and Analytical Chemistry, School of Chemistry, Andhra University,.

  17. Short communication

    NARCIS (Netherlands)

    Pantophlet, Andre J.; Gilbert, M.S.; Gerrits, W.J.J.; Vonk, R.J.

    2017-01-01

    Heavy veal calves (4-6 mo old) often develop problems with insulin sensitivity. This could lead to metabolic disorders and impaired animal growth performance. Studies in various animal species have shown that the supplementation of short-chain fructo-oligosaccharides (scFOS) can improve insulin

  18. Short Communication

    African Journals Online (AJOL)

    huis

    Short Communication. QTL analysis of production traits on SSC3 in a Large White×Meishan pig resource family. B. Zuo. 1. , Y.Z. Xiong. 1#. , Y.H. Su. 2. , C.Y. Deng. 1. , M.G. Lei. 1. , F.E. Li. 1. , R. Zheng. 1 and S.W. Jiang. 1. 1 Key Laboratory of Swine Genetics and Breeding, Ministry of Agriculture & Key Lab of Agricultural ...

  19. Plasma expansion: fundamentals and applications

    International Nuclear Information System (INIS)

    Engeln, R; Mazouffre, S; Vankan, P; Bakker, I; Schram, D C

    2002-01-01

    The study of plasma expansion is interesting from a fundamental point of view as well as from a more applied point of view. We here give a short overview of the way properties like density, velocity and temperature behave in an expanding thermal plasma. Experimental data show that the basic phenomena of plasma expansion are to some extent similar to those of the expansion of a hot neutral gas. From the application point of view, we present first results on the use of an expanding thermal plasma in the plasma-activated catalysis of ammonia, from N 2 -H 2 mixtures

  20. X-ray hot plasma diagnostics

    International Nuclear Information System (INIS)

    Cojocaru, E.

    1984-11-01

    X-ray plasma emission study is powerful diagnostic tool of hot plasmas. In this review article the main techniques of X-ray plasma emission measurement are shortly presented: X-ray spectrometry using absorbent filters, crystal and grating spectrometers, imaging techniques using pinhole cameras, X-ray microscopes and Fresnel zone plate cameras, X-ray plasma emission calorimetry. Advances in these techniques with examples for different hot plasma devices are also presentes. (author)

  1. Plasma turbulence

    International Nuclear Information System (INIS)

    Horton, W.

    1998-07-01

    The origin of plasma turbulence from currents and spatial gradients in plasmas is described and shown to lead to the dominant transport mechanism in many plasma regimes. A wide variety of turbulent transport mechanism exists in plasmas. In this survey the authors summarize some of the universally observed plasma transport rates

  2. Meia-vida do ametryn em argissolo vermelho-amarelo e latossolo vermelho-amarelo, com diferentes valores de pH Determination of half-life of ametryn on red-yellow latosol and red-yellow ultisol with different pH values

    Directory of Open Access Journals (Sweden)

    S.R.B. Andrade

    2010-06-01

    Full Text Available Objetivou-se com este trabalho determinar a meia-vida (t½ do herbicida ametryn em Argissolo Vermelho-Amarelo e Latossolo Vermelho-Amarelo, com diferentes valores de pH. Foram utilizados vasos revestidos internamente com filme plástico e preenchidos com 330,0 g de amostras dos solos em estudo (Latossolo Vermelho-Amarelo - LVA com valores de pH corrigidos para 4,4, 4,9 e 5,8, e Argissolo Vermelho-Amarelo - PVA com pH 5,9. As amostras desses solos foram coletadas em pastagens degradadas isentas da aplicação de herbicidas. A essas amostras foi aplicado o ametryn na dose de 2,5 L ha-1. Doze horas após essa aplicação, foram retiradas as primeiras amostras de solo dos vasos, para determinação da concentração no tempo zero, e a cada cinco dias foram retiradas novas amostras de outros vasos, visando à determinação da concentração de ametryn ao longo do tempo. A extração do ametryn da matriz solo foi realizada por Extração Sólido Líquido com Partição em Baixa Temperatura (ESL-PBT, e o herbicida, quantificado por cromatografia líquida de alta eficiência - CLAE. Foi realizado, em paralelo, um teste biológico para determinação indireta da persistência do herbicida. A análise dos dados indicou que a meia-vida (t½ do ametryn nos solos avaliados foi de 26, 19, 12 e 11 dias para os solos LVA pH 4,4; LVA pH 4,9; LVA pH 5,8; e PVA pH 5,9, respectivamente. Ambos os métodos (cromatografia ou bioensaios utilizados para avaliação da persistência do ametryn nos solos evidenciaram que a degradação desse herbicida é muito influenciada pelo pH do solo e pelo teor de matéria orgânica.The objective of this study was to determine the half-life (t½ for the herbicide ametryn in Red-Yellow Latosol (LVA and Red-Yellow Ultisol (PVA with different pH values. Thus, plastic pots coated inside with plastic film were filled with 330 g of samples from the soils under study (LVA with pH values adjusted to 4.4, 4.9 and 5.8, and PVA pH 5

  3. [Relation between dose, plasma concentration and therapeutic effect of theophylline in children with sleep apnea].

    Science.gov (United States)

    Rodríguez-Palomares, C; Ugartechea, J C; Palma-Aguirre, J A; Juárez-Olguín, H; Calderón-Mandujano, B

    1989-12-01

    The plasma concentration of theophylline was determined in twelve children with infantile sleep apnea (average age 48.5 days). The purpose of the study was to correlate concentrations with the dosages given, the therapeutic response and any adverse effects which could arise. In addition, other pharmacokinetic values were found, half-life (t 1/2) and clearance concentrations (Clss). The oral maintenance dose used was 4 mg/kg/24 h. The serum concentration of theophylline was determined by a homogeneous immunoassay enzyme technique (EMIT). A bad correlation was found (r = 0.45) between the oral dosage given and the plasma concentrations found. This was probably due to variations in the clearance of the drug. Yet, plasma concentrations fell between 3.0 and 12.6 micrograms/mL, enough to satisfactorily control apneic episodes in all the children included in the study without undesirable side-effects. Only one patient had some trouble in falling asleep and showed signs of irritability. The half-life was 13.30 +/- 7.46 hours and Clss was 36.64 +/- 12.98 mL/h/kg. In general, our results correlate with those reported in the literature. The accuracy of the pharmacokinetic parameters with two samples is reliable, therefore avoiding the use of multiple sampling in this group of children.

  4. Review on plasmas in extraordinary media: plasmas in cryogenic conditions and plasmas in supercritical fluids

    Science.gov (United States)

    Stauss, Sven; Muneoka, Hitoshi; Terashima, Kazuo

    2018-02-01

    Plasma science and technology has enabled advances in very diverse fields: micro- and nanotechnology, chemical synthesis, materials fabrication and, more recently, biotechnology and medicine. While many of the currently employed plasma tools and technologies are very advanced, the types of plasmas used in micro- and nanofabrication pose certain limits, for example, in treating heat-sensitive materials in plasma biotechnology and plasma medicine. Moreover, many physical properties of plasmas encountered in nature, and especially outer space, i.e. very-low-temperature plasmas or plasmas that occur in high-density media, are not very well understood. The present review gives a short account of laboratory plasmas generated under ’extreme’ conditions: at cryogenic temperatures and in supercritical fluids. The fundamental characteristics of these cryogenic plasmas and cryoplasmas, and plasmas in supercritical fluids, especially supercritical fluid plasmas, are presented with their main applications. The research on such exotic plasmas is expected to lead to further understanding of plasma physics and, at the same time, enable new applications in various technological fields.

  5. Studies on the separation of rare earth elements and the nuclear decay properties of short lived rare-earth nuclides in U-235 fission products

    International Nuclear Information System (INIS)

    Ohyoshi, Akira; Ohyoshi, Emiko.

    1980-01-01

    The effect of a complex-forming agent, with which rare earths consecutively form the complexes, on the separation of a pair of adjacent rare earths by electromigration has been investigated. The relation between the separation factor for two complexes and the ligand-ion concentration was examined in the separation of La-Ce and Ce-Pr pairs with nitrilotriacetic acid. Rare earths were able to be isolated rapidly at the optimum ligand-ion concentration in lower one, and this method was applied to study the nuclear decay properties of the short lived isotopes of La, Ce, Pr, Nd and Yt formed in the fission of U-235. This method permits the direct measurement of the decay of La-144 without the interference from the radiation of other fission products. The gamma-ray spectrum of La-144 was measured with a high resolution Ge(Li) detector, and the gamma-transition was observed. From the decay plots of two strong photopeaks, the half-life of La-144 was determined. In the case of Ce fraction, the photopeaks assigned to respective isotopes were observed. In the studies on the decay properties of Pr-148 and Pr-149, the decay plot of the strong photopeak showed good linearity, and the accurate half-life of Pr-148 was determined. Similarly, the half-life of Pr-149 was longer than the previously reported value. (Kako, I.)

  6. Plasma Volume Expansion Resulting from Intravenous Glucose Tolerance Test

    Directory of Open Access Journals (Sweden)

    Robert G. Hahn

    2011-01-01

    Full Text Available Objective. To quantify the degree of plasma volume expansion that occurs during an intravenous glucose tolerance test (IVGTT. Methods. Twenty healthy volunteers (mean age, 28 years underwent IVGTTs in which 0.3 g/kg of glucose 30% was injected as a bolus over 1 min. Twelve blood samples were collected over 75 min. The plasma glucose and blood hemoglobin concentrations were used to calculate the volume distribution (Vd and the clearance (CL of both the exogenous glucose and the injected fluid volume. Results. The IVGTT caused a virtually instant plasma volume expansion of 10%. The half-life of the glucose averaged 15 min and the plasma volume expansion 16 min. Correction of the fluid kinetic model for osmotic effects after injection reduced CL for the infused volume by 85%, which illustrates the strength of osmosis in allocating fluid back to the intracellular fluid space. Simulations indicated that plasma volume expansion can be reduced to 60% by increasing the injection time from 1 to 5 min and reducing the glucose load from 0.3 to 0.2 g/kg. Conclusion. A regular IVGTT induced an acute plasma volume expansion that peaked at 10% despite the fact that only 50–80 mL of fluid were administered.

  7. Plasma properties

    International Nuclear Information System (INIS)

    Weitzner, H.

    1990-06-01

    This paper discusses the following topics: MHD plasma activity: equilibrium, stability and transport; statistical analysis; transport studies; edge physics studies; wave propagation analysis; basic plasma physics and fluid dynamics; space plasma; and numerical methods

  8. Pharmacodynamics of recombinant activated factor VII and plasma-derived factor VII in a cohort of severe FVII deficient patients.

    Science.gov (United States)

    van Geffen, Mark; Mathijssen, Natascha C J; Holme, Pål A; Laros-van Gorkom, Britta A P; van Kraaij, Marian G J; Masereeuw, Roselinde; Peyvandi, Flora; van Heerde, Waander L

    2013-07-01

    Recombinant activated factor VII (rFVIIa) and plasma-derived factor VII (pdFVII) are used to prevent bleedings in severe FVII deficient patients, despite their short half-lifes. It is suggested that FVII levels of 15-20 IU/dL are sufficient to maintain hemostasis. We analyzed the pharmacodynamic effects of FVII substitution therapy in the Nijmegen Hemostasis Assay (NHA) that simultaneously measures thrombin and plasmin generation. Ten severe FVII deficient patients were treated with 20 μg/kg rFVIIa or 25 IU/kg pdFVII in a cross-over design. Thrombin generation lag-time (TG-LT) was identified as an effect-response parameter. Pharmacodynamic analysis using a maximum effect model showed 50% reduction of the TG-LT effect at ~2 IU/dL FVII activity for both rFVIIa and pdFVII. The FVII activity to obtain TG-LT comparable to the upper limit of normal range in healthy controls (4 min) was given by the effective concentration (ECnormal), showing sufficient hemostasis at 3-4 IU/dL FVII activity. No association was seen between FVII activity and other thrombin or plasmin generation parameters as measured by NHA. In conclusion, 3-4 IU/dL FVII activity seems sufficient to maintain hemostasis in patients with severe FVII deficiency during prophylaxis. These data may suggest a potential value for measurement of TG-LT in the monitoring of FVII(a) therapy. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Plasma accelerators

    International Nuclear Information System (INIS)

    Bingham, R.; Angelis, U. de; Johnston, T.W.

    1991-01-01

    Recently attention has focused on charged particle acceleration in a plasma by a fast, large amplitude, longitudinal electron plasma wave. The plasma beat wave and plasma wakefield accelerators are two efficient ways of producing ultra-high accelerating gradients. Starting with the plasma beat wave accelerator (PBWA) and laser wakefield accelerator (LWFA) schemes and the plasma wakefield accelerator (PWFA) steady progress has been made in theory, simulations and experiments. Computations are presented for the study of LWFA. (author)

  10. Use of short-lived radionuclides in the agricultural and environmental sciences

    International Nuclear Information System (INIS)

    Krohn, K.A.

    1985-01-01

    In addition to their well-known uses in physiology, biochemistry, and medicine, short-lived radioisotopes have played an important part in promoting the authors knowledge of the agricultural and environmental sciences. Numerous investigators have found that the scientific rewards justify the additional demands associated with use of short-lived radioisotopes when novel or uniquely precise results can be achieved. This is best exemplified by examining the use of 13 N. Nitrogen-13 is the longest lived radioisotope of this very important element. The 10-min half-life of 13 N has required that the agricultural or environmental test model be brought to the laboratory where the isotope is made, but this has been done successfully in numerous instances. One major incentive for this research has probably been the fact that there is no analog of the very useful 14 C tracer to study nitrogen chemistry and biology

  11. Computational plasma physics

    International Nuclear Information System (INIS)

    Killeen, J.

    1975-08-01

    The behavior of a plasma confined by a magnetic field is simulated by a variety of numerical models. Some models used on a short time scale give detailed knowledge of the plasma on a microscopic scale, while other models used on much longer time scales compute macroscopic properties of the plasma dynamics. In the last two years there has been a substantial increase in the numerical modelling of fusion devices. The status of MHD, transport, equilibrium, stability, Vlasov, Fokker-Planck, and Hybrid codes is reviewed. These codes have already been essential in the design and understanding of low and high beta toroidal experiments and mirror systems. The design of the next generation of fusion experiments and fusion test reactors will require continual development of these numerical models in order to include the best available plasma physics description and also to increase the geometric complexity of the model. (auth)

  12. Plasma device

    International Nuclear Information System (INIS)

    Thode, L.E.

    1981-01-01

    A method is described for electron beam heating of a high-density plasma to drive a fast liner. An annular or solid relativistic electron beam is used to heat a plasma to kilovolt temperatures through streaming instabilities in the plasma. Energy deposited in the plasma then converges on a fast liner to explosively or ablatively drive the liner to implosion. (U.K.)

  13. Plasma Modes

    Science.gov (United States)

    Dubin, D. H. E.

    This chapter explores several aspects of the linear electrostatic normal modes of oscillation for a single-species non-neutral plasma in a Penning trap. Linearized fluid equations of motion are developed, assuming the plasma is cold but collisionless, which allow derivation of the cold plasma dielectric tensor and the electrostatic wave equation. Upper hybrid and magnetized plasma waves in an infinite uniform plasma are described. The effect of the plasma surface in a bounded plasma system is considered, and the properties of surface plasma waves are characterized. The normal modes of a cylindrical plasma column are discussed, and finally, modes of spheroidal plasmas, and finite temperature effects on the modes, are briefly described.

  14. Comparison of short-lived medical isotopes activation by laser thin target induced protons and conventional cyclotron proton beams

    Science.gov (United States)

    Murray, Joseph; Dudnikova, Galina; Liu, Tung-Chang; Papadopoulos, Dennis; Sagdeev, Roald; Su, J. J.; UMD MicroPET Team

    2014-10-01

    Production diagnostic or therapeutic nuclear medicines are either by nuclear reactors or by ion accelerators. In general, diagnostic nuclear radioisotopes have a very short half-life varying from tens of minutes for PET tracers and few hours for SPECT tracers. Thus supplies of PET and SPECT radiotracers are limited by regional production facilities. For example 18F-fluorodeoxyglucose (FDG) is the most desired tracer for positron emission tomography because its 110 minutes half-life is sufficient long for transport from production facilities to nearby users. From nuclear activation to completing image taking must be done within 4 hours. Decentralized production of diagnostic radioisotopes will be idea to make high specific activity radiotracers available to researches and clinicians. 11 C, 13 N, 15 O and 18 F can be produced in the energy range from 10-20 MeV by protons. Protons of energies up to tens of MeV generated by intense laser interacting with hydrogen containing targets have been demonstrated by many groups in the past decade. We use 2D PIC code for proton acceleration, Geant4 Monte Carlo code for nuclei activation to compare the yields and specific activities of short-lived isotopes produced by cyclotron proton beams and laser driven protons.

  15. Plasma diagnostic reflectometry

    International Nuclear Information System (INIS)

    Cohen, B.I.; Afeyan, B.B.; Garrison, J.C.; Kaiser, T.B.; Luhmann, N.C. Jr.; Domier, C.W.; Chou, A.E.; Baang, S.

    1996-01-01

    Theoretical and experimental studies of plasma diagnostic reflectometry have been undertaken as a collaborative research project between the Lawrence Livermore National Laboratory (LLNL) and the University of California Department of Applied Science Plasma Diagnostics Group under the auspices of the Laboratory Directed Research and Development Program at LLNL. Theoretical analyses have explored the basic principles of reflectometry to understand its limitations, to address specific gaps in the understanding of reflectometry measurements in laboratory experiments, and to explore extensions of reflectometry such as ultra-short-pulse reflectometry. The theory has supported basic laboratory reflectometry experiments where reflectometry measurements can be corroborated by independent diagnostic measurements

  16. Plasma centrifuges

    International Nuclear Information System (INIS)

    Karchevskij, A.I.; Potanin, E.P.

    2000-01-01

    The review of the most important studies on the isotope separation processes in the rotating plasma is presented. The device is described and the characteristics of operation of the pulse plasma centrifuges with weakly and strongly ionized plasma as well as the stationary plasma centrifuges with the medium weak ionization and devices, applying the stationary vacuum arc with the high ionization rate and the stationary beam-plasma discharge with complete ionization, are presented. The possible mechanisms of the isotope separation in plasma centrifuges are considered. The specific energy consumption for isotope separation in these devices is discussed [ru

  17. Plasma astrophysics

    CERN Document Server

    Kaplan, S A; ter Haar, D

    2013-01-01

    Plasma Astrophysics is a translation from the Russian language; the topics discussed are based on lectures given by V.N. Tsytovich at several universities. The book describes the physics of the various phenomena and their mathematical formulation connected with plasma astrophysics. This book also explains the theory of the interaction of fast particles plasma, their radiation activities, as well as the plasma behavior when exposed to a very strong magnetic field. The text describes the nature of collective plasma processes and of plasma turbulence. One author explains the method of elementary

  18. Plasma waves

    CERN Document Server

    Swanson, DG

    1989-01-01

    Plasma Waves discusses the basic development and equations for the many aspects of plasma waves. The book is organized into two major parts, examining both linear and nonlinear plasma waves in the eight chapters it encompasses. After briefly discussing the properties and applications of plasma wave, the book goes on examining the wave types in a cold, magnetized plasma and the general forms of the dispersion relation that characterize the waves and label the various types of solutions. Chapters 3 and 4 analyze the acoustic phenomena through the fluid model of plasma and the kinetic effects. Th

  19. Laser surface wakefield in a plasma column

    International Nuclear Information System (INIS)

    Gorbunov, L.M.; Mora, P.; Ramazashvili, R.R.

    2003-01-01

    The structure of the wakefield in a plasma column, produced by a short intense laser pulse, propagating through a gas affected by tunneling ionization is investigated. It is shown that besides the usual plasma waves in the bulk part of the plasma column [see Andreev et al., Phys. Plasmas 9, 3999 (2002)], the laser pulse also generates electromagnetic surface waves propagating along the column boundary. The length of the surface wake wave substantially exceeds the length of the plasma wake wave and its electromagnetic field extends far outside the plasma column

  20. The remarkable stability of chimeric, sialic acid-derived alpha/delta-peptides in human blood plasma.

    Science.gov (United States)

    Saludes, Jonel P; Natarajan, Arutselvan; DeNardo, Sally J; Gervay-Hague, Jacquelyn

    2010-05-01

    Peptides are labile toward proteolytic enzymes, and structural modifications are often required to prolong their metabolic half-life and increase resistance. One modification is the incorporation of non-alpha-amino acids into the peptide to deter recognition by hydrolytic enzymes. We previously reported the synthesis of chimeric alpha/delta-peptides from glutamic acids (Glu) and the sialic acid derivative Neu2en. Conformational analyses revealed these constructs adopt secondary structures in water and may serve as conformational surrogates of polysialic acid. Polysialic acid is a tumor-associated polysaccharide and is correlated with cancer metastasis. Soluble polysialic acid is rapidly cleared from the blood limiting its potential for vaccine development. One motivation in developing structural surrogates of polysialic acid was to create constructs with increased bioavailability. Here, we report plasma stability profiles of Glu/Neu2en alpha/delta-peptides. DOTA was conjugated at the peptide N-termini by solid phase peptide synthesis, radiolabeled with (111)In, incubated in human blood plasma at 37 degrees C, and their degradation patterns monitored by cellulose acetate electrophoresis and radioactivity counting. Results indicate that these peptides exhibit a long half-life that is two- to three-orders of magnitude higher than natural alpha-peptides. These findings provide a viable platform for the synthesis of plasma stable, sialic acid-derived peptides that may find pharmaceutical application.