WorldWideScience

Sample records for sheet emergency disinfection

  1. Emergency Disinfection of Drinking Water

    Science.gov (United States)

    How to boil and disinfect water to kill most disease-causing microorganisms during emergency situations where regular water service has been interrupted and local authorities recommend using only bottled water, boiled water, or disinfected water.

  2. Thermodynamic properties of an emerging chemical disinfectant, peracetic acid.

    Science.gov (United States)

    Zhang, Chiqian; Brown, Pamela J B; Hu, Zhiqiang

    2018-04-15

    Peracetic acid (PAA or CH 3 COOOH) is an emerging disinfectant with a low potential to form carcinogenic disinfection by-products (DBPs). Basic thermodynamic properties of PAA are, however, absent or inconsistently reported in the literature. This review aimed to summarize important thermodynamic properties of PAA, including standard Gibbs energy of formation and oxidation-reduction (redox) potential. The standard Gibbs energies of formation of CH 3 COOOH (aq) , CH 3 COOOH (g) , CH 3 COOOH (l) , and CH 3 COOO (aq) - are -299.41kJ·mol -1 , -283.02kJ·mol -1 , -276.10kJ·mol -1 , and -252.60kJ·mol -1 , respectively. The standard redox potentials of PAA are 1.748V and 1.005V vs. standard hydrogen electrode (SHE) at pH 0 and pH 14, respectively. Under biochemical standard state conditions (pH 7, 25°C, 101,325Pa), PAA has a redox potential of 1.385V vs. SHE, higher than many disinfectants. Finally, the environmental implications of the thermodynamic properties of PAA were systematically discussed. Those properties can be used to predict the physicochemical and biological behavior of aquatic systems exposed to PAA. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Nuclear accident dosimetry. Revision of emergency data sheets

    International Nuclear Information System (INIS)

    Delafield, H.J.

    1976-09-01

    The Emergency Data Sheets on Nuclear Accident Dosimetry have been revealed following the publication of a three part manual on this subject (Delafield, Dennis and Gibson, AERE-R 7485/6/7, 1973). This memo provides an explanation of the action levels adopted for the initial segregation of irradiated persons following a criticality accident, by monitoring the activity of indium foils contained in personnel dosimeters and the induced body sodium activity. The data sheets are given as an Appendix. They provide basic information on; the segregation of irradiated persons, the estimation of radiation exposure, and the assessment of personnel γ-ray and neutron doses. (author)

  4. Oil Notifications: Emergency Response Notification System (ERNS) fact sheet

    International Nuclear Information System (INIS)

    1992-04-01

    The Emergency Response Notification System (ERNS) is a national computer database which provides the only centralized mechanism for documenting and verifying incident notification information as initially reported to the National Response Center (NRC), the U.S. Environmental Protection Agency (EPA), and to a limited extent, the U.S. Coast Guard (USCG). The initial notification data may be followed up with updated information from various Federal, State and local response authorities, as appropriate. ERNS contains data that can be used to analyze release notifications, support emergency planning efforts, and assist decision makers in developing spill prevention programs. The fact sheet provides summary information on notifications of releases of oil reported in accordance with the Clean Water Act (CWA). Under Section 311 of the CWA, discharges of oil which: (1) cause a sheen to appear on the surface of the water; (2) violate applicable water quality standards; or (3) cause sludge or emulsion to be deposited beneath the surface of the water or adjoining shoreline, must be reported to the NRC

  5. Biological efficacy and toxic effect of emergency water disinfection process based on advanced oxidation technology.

    Science.gov (United States)

    Tian, Yiping; Yuan, Xiaoli; Xu, Shujing; Li, Rihong; Zhou, Xinying; Zhang, Zhitao

    2015-12-01

    An innovative and removable water treatment system consisted of strong electric field discharge and hydrodynamic cavitation based on advanced oxidation technologies was developed for reactive free radicals producing and waterborne pathogens eliminating in the present study. The biological efficacy and toxic effects of this advanced oxidation system were evaluated during water disinfection treatments. Bench tests were carried out with synthetic microbial-contaminated water, as well as source water in rainy season from a reservoir of Dalian city (Liaoning Province, China). Results showed that high inactivation efficiency of Escherichia coli (>5 log) could be obtained for synthetic contaminated water at a low concentration (0.5-0.7 mg L(-1)) of total oxidants in 3-10 s. The numbers of wild total bacteria (108 × 10(3) CFU mL(-1)) and total coliforms (260 × 10(2) MPN 100 mL(-1)) in source water greatly reduced to 50 and 0 CFU mL(-1) respectively after treated by the advanced oxidation system, which meet the microbiological standards of drinking water, and especially that the inactivation efficiency of total coliforms could reach 100%. Meanwhile, source water qualities were greatly improved during the disinfection processes. The values of UV254 in particular were significantly reduced (60-80%) by reactive free radicals. Moreover, the concentrations of possible disinfection by-products (formaldehyde and bromide) in treated water were lower than detection limits, indicating that there was no harmful effect on water after the treatments. These investigations are helpful for the ecotoxicological studies of advanced oxidation system in the treatments of chemical polluted water or waste water. The findings of this work suggest that the developed water treatment system is ideal in the acute phases of emergencies, which also could offer additional advantages over a wide range of applications in water pollution control.

  6. Analysis, Occurrence and Toxicity of Haloacetaldehydes in Drinking Waters: Iodacetaldehyde as an Emerging Disinfection ByProduct.

    Science.gov (United States)

    Chlorinated and brominated haloacetaldehydes (HALs) are consideredthe 3rd largest class of disinfection by-products (DBPs) by weight. The iodinatedHAL, iodoacetaldehyde, has been recently reported as an emerging DBP infinished drinking waters. Overall, iodinated DBPs, e.g., iodoa...

  7. The pattern of anthropogenic signal emergence in Greenland Ice Sheet surface mass balance

    NARCIS (Netherlands)

    Fyke, J.G.; Vizcaino, M.; Lipscomb, W.H.

    2014-01-01

    Surface mass balance (SMB) trends influence observed Greenland Ice Sheet (GrIS) mass loss, but the component of these trends related to anthropogenic forcing is unclear. Here we study the simulated spatial pattern of emergence of an anthropogenically derived GrIS SMB signal between 1850 and 2100

  8. Minimizing the Risk of Disease Transmission in Emergency Settings: Novel In Situ Physico-Chemical Disinfection of Pathogen-Laden Hospital Wastewaters.

    Directory of Open Access Journals (Sweden)

    Emanuele Sozzi

    Full Text Available The operation of a health care facility, such as a cholera or Ebola treatment center in an emergency setting, results in the production of pathogen-laden wastewaters that may potentially lead to onward transmission of the disease. The research presented here evaluated the design and operation of a novel treatment system, successfully used by Médecins Sans Frontières in Haiti to disinfect CTC wastewaters in situ, eliminating the need for road haulage and disposal of the waste to a poorly-managed hazardous waste facility, thereby providing an effective barrier to disease transmission through a novel but simple sanitary intervention. The physico-chemical protocols eventually successfully treated over 600 m3 of wastewater, achieving coagulation/flocculation and disinfection by exposure to high pH (Protocol A and low pH (Protocol B environments, using thermotolerant coliforms as a disinfection efficacy index. In Protocol A, the addition of hydrated lime resulted in wastewater disinfection and coagulation/flocculation of suspended solids. In Protocol B, disinfection was achieved by the addition of hydrochloric acid, followed by pH neutralization and coagulation/flocculation of suspended solids using aluminum sulfate. Removal rates achieved were: COD >99%; suspended solids >90%; turbidity >90% and thermotolerant coliforms >99.9%. The proposed approach is the first known successful attempt to disinfect wastewater in a disease outbreak setting without resorting to the alternative, untested, approach of 'super chlorination' which, it has been suggested, may not consistently achieve adequate disinfection. A basic analysis of costs demonstrated a significant saving in reagent costs compared with the less reliable approach of super-chlorination. The proposed approach to in situ sanitation in cholera treatment centers and other disease outbreak settings represents a timely response to a UN call for onsite disinfection of wastewaters generated in such

  9. Bacterial Contamination and Disinfection Status of Laryngoscopes Stored in Emergency Crash Carts

    Science.gov (United States)

    Lee, Jung Won; Shin, Hee Bong; Lee, In Kyung

    2017-01-01

    Objectives To identify bacterial contamination rates of laryngoscope blades and handles stored in emergency crash carts by hospital and area according to the frequency of intubation attempts. Methods One hundred forty-eight handles and 71 blades deemed ready for patient use from two tertiary hospitals were sampled with sterile swabs using a standardized rolling technique. Samples were considered negative (not contaminated) if no colonies were present on the blood agar plate after an 18-hour incubation period. Samples were stratified by hospital and according to the frequency of intubation attempts (10 attempts per year) using the χ2-test and Fisher exact test. Results One or more species of bacteria were isolated from 4 (5.6%) handle tops, 20 (28.2%) handles with knurled surfaces, and 27 (18.2%) blades. No significant differences were found in microbial contamination levels on the handle tops and blades between the two hospitals and two areas according to the frequency of intubation attempts. However, significant differences were found between the two hospitals and two areas in the level of microbial contamination on the handles with knurled surfaces (pdisinfect laryngoscope blades and handles; handles should be re-designed to eliminate points of contact with the blade; and single-use, one-piece laryngoscopes should be introduced. PMID:28605891

  10. New directions in the science and technology of advanced sheet explosive formulations and the key energetic materials used in the processing of sheet explosives: Emerging trends.

    Science.gov (United States)

    Talawar, M B; Jangid, S K; Nath, T; Sinha, R K; Asthana, S N

    2015-12-30

    This review presents the work carried out by the international community in the area of sheet explosive formulations and its applications in various systems. The sheet explosive is also named as PBXs and is a composite material in which solid explosive particles like RDX, HMX or PETN are dispersed in a polymeric matrix, forms a flexible material that can be rolled/cut into sheet form which can be applied to any complex contour. The designed sheet explosive must possess characteristic properties such as flexible, cuttable, water proof, easily initiable, and safe handling. The sheet explosives are being used for protecting tanks (ERA), light combat vehicle and futuristic infantry carrier vehicle from different attacking war heads etc. Besides, sheet explosives find wide applications in demolition of bridges, ships, cutting and metal cladding. This review also covers the aspects such as risks and hazard analysis during the processing of sheet explosive formulations, effect of ageing on sheet explosives, detection and analysis of sheet explosive ingredients and the R&D efforts of Indian researchers in the development of sheet explosive formulations. To the best of our knowledge, there has been no review article published in the literature in the area of sheet explosives. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Improving stethoscope disinfection at a children's hospital.

    Science.gov (United States)

    Zaghi, Justin; Zhou, Jing; Graham, Dionne A; Potter-Bynoe, Gail; Sandora, Thomas J

    2013-11-01

    Stethoscopes are contaminated with pathogenic bacteria and pose a risk for transmission of infections, but few clinicians disinfect their stethoscope after every use. We sought to improve stethoscope disinfection rates among pediatric healthcare providers by providing access to disinfection materials and visual reminders to disinfect stethoscopes. Prospective intervention study. Inpatient units and emergency department of a major pediatric hospital. Physicians and nurses with high anticipated stethoscope use. Baskets filled with alcohol prep pads and a sticker reminding providers to regularly disinfect stethoscopes were installed outside of patient rooms. Healthcare providers' stethoscope disinfection behaviors were directly observed before and after the intervention. Multivariable logistic regression models were created to identify independent predictors of stethoscope disinfection. Two hundred twenty-six observations were made in the preintervention period and 261 in the postintervention period (83% were of physicians). Stethoscope disinfection compliance increased significantly from a baseline of 34% to 59% postintervention (P stethoscope disinfection supplies and visible reminders outside of patient rooms significantly increased stethoscope disinfection rates among physicians and nurses at a children's hospital. This simple intervention could be replicated at other healthcare facilities. Future research should assess the impact on patient infections.

  12. Formation of Emerging Disinfection By-products by Chlorination/Chloramination of Seawater Impacted by Algal Organic Matter

    KAUST Repository

    Nihemaiti, Maolida

    2015-08-31

    The aim of this work was to study the formation of haloacetamides (HAcAms) and other DBPs during chlorination and chloramination of algal organic matter (AlOM). The HAcAms formation potentials of different precursors (amino acids, simulated algal blooms grown in the Red Sea) were evaluated. Experiments with simulated algal blooms were conducted in the presence of bromide ion (synthetic seawater containing 800 μg/L Br−) to assess the formation of brominated analogues of HAcAms in conditions close to the disinfection of real seawater. Chlorination produced more HAcAms than chloramination from real algae (Synecococcus sp.), thus indicating that the nitrogen of HAcAms comes predominantly from DON through the decarboxylation of amino acids rather than from NH2Cl. Dibrominated species of DBPs (i.e., DBAcAm, DBAA and DBAN) were the dominant species formed by both chlorination and chloramination of algal bloom samples. Chloramination of the amino acid asparagine produced an important amount of DCAcAm as compared to chlorination, indicating the existence of a specific reaction pathway.

  13. Formation of Emerging Disinfection By-products by Chlorination/Chloramination of Seawater Impacted by Algal Organic Matter

    KAUST Repository

    Nihemaiti, Maolida; Le Roux, Julien; Croue, Jean-Philippe

    2015-01-01

    The aim of this work was to study the formation of haloacetamides (HAcAms) and other DBPs during chlorination and chloramination of algal organic matter (AlOM). The HAcAms formation potentials of different precursors (amino acids, simulated algal blooms grown in the Red Sea) were evaluated. Experiments with simulated algal blooms were conducted in the presence of bromide ion (synthetic seawater containing 800 μg/L Br−) to assess the formation of brominated analogues of HAcAms in conditions close to the disinfection of real seawater. Chlorination produced more HAcAms than chloramination from real algae (Synecococcus sp.), thus indicating that the nitrogen of HAcAms comes predominantly from DON through the decarboxylation of amino acids rather than from NH2Cl. Dibrominated species of DBPs (i.e., DBAcAm, DBAA and DBAN) were the dominant species formed by both chlorination and chloramination of algal bloom samples. Chloramination of the amino acid asparagine produced an important amount of DCAcAm as compared to chlorination, indicating the existence of a specific reaction pathway.

  14. Removal of the precursors of N-nitrosodiethylamine (NDEA), an emerging disinfection byproduct, in drinking water treatment process and its toxicity to adult zebrafish (Danio rerio).

    Science.gov (United States)

    Zheng, Jian; Lin, Tao; Chen, Wei

    2018-01-01

    N-nitrosodiethylamine (NDEA) is one of the emerging nitrogenous disinfection byproducts with probable cytotoxicity, genotoxicity, and carcinogenesis. Its potential toxicological effects have received extensive attention but remain to be poorly understood. In this study, changes in NDEA precursors in drinking water treatment process were studied using the trial of its formation potential (FP), and the toxicity induced by NDEA to adult zebrafish was investigated. NDEA FP in the raw water of Taihu Lake ranged from 46.9 to 68.3 ng/L. The NDEA precursors were removed effectively by O 3 /BAC process. Hydrophilic fraction and low-molecular-weight fraction (stress and antioxidant defense to zebrafish metabolism system at concentrations over 5 μg/L. After a 42-day exposure, a significant DNA damage was observed in zebrafish liver cells at NDEA concentrations beyond 500 μg/L. This study investigated NDEA properties in both engineering prospective and toxicity evaluation, thus providing comprehensive information on its control in drinking water treatment process and its toxicity effect on zebrafish as a model animal. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Spiral-shaped disinfection reactors

    KAUST Repository

    Ghaffour, Noreddine

    2015-08-20

    This disclosure includes disinfection reactors and processes for the disinfection of water. Some disinfection reactors include a body that defines an inlet, an outlet, and a spiral flow path between the inlet and the outlet, in which the body is configured to receive water and a disinfectant at the inlet such that the water is exposed to the disinfectant as the water flows through the spiral flow path. Also disclosed are processes for disinfecting water in such disinfection reactors.

  16. Spiral-shaped disinfection reactors

    KAUST Repository

    Ghaffour, NorEddine; Ait-Djoudi, Fariza; Naceur, Wahib Mohamed; Soukane, Sofiane

    2015-01-01

    This disclosure includes disinfection reactors and processes for the disinfection of water. Some disinfection reactors include a body that defines an inlet, an outlet, and a spiral flow path between the inlet and the outlet, in which the body

  17. Applications of Photocatalytic Disinfection

    Directory of Open Access Journals (Sweden)

    Joanne Gamage

    2010-01-01

    Full Text Available Due to the superior ability of photocatalysis to inactivate a wide range of harmful microorganisms, it is being examined as a viable alternative to traditional disinfection methods such as chlorination, which can produce harmful byproducts. Photocatalysis is a versatile and effective process that can be adapted for use in many applications for disinfection in both air and water matrices. Additionally, photocatalytic surfaces are being developed and tested for use in the context of “self-disinfecting” materials. Studies on the photocatalytic technique for disinfection demonstrate this process to have potential for widespread applications in indoor air and environmental health, biological, and medical applications, laboratory and hospital applications, pharmaceutical and food industry, plant protection applications, wastewater and effluents treatment, and drinking water disinfection. Studies on photocatalytic disinfection using a variety of techniques and test organisms are reviewed, with an emphasis on the end-use application of developed technologies and methods.

  18. Hospital disinfection: efficacy and safety issues.

    Science.gov (United States)

    Dettenkofer, Markus; Block, Colin

    2005-08-01

    To review recent publications relevant to hospital disinfection (and cleaning) including the reprocessing of medical instruments. The key question as to whether the use of disinfectants on environmental surfaces rather than cleaning with detergents only reduces nosocomial infection rates still awaits conclusive studies. New disinfectants, mainly peroxygen compounds, show good sporicidal properties and will probably replace more problematical substances such as chlorine-releasing agents. The safe reprocessing of medical devices requires a well-coordinated approach, starting with proper cleaning. New methods and substances show promising activity for preventing the transmission of prions. Different aspects of virus inactivation have been studied, and the transmissibility, e.g. of norovirus, shows the need for sound data on how different disinfectant classes perform. Biofilms or other forms of surface-adherent organisms pose an extraordinary challenge to decontamination. Although resistance to biocides is generally not judged to be as critical as antibiotic resistance, scientific data support the need for proper use, i.e. the avoidance of widespread application, especially in low concentrations and in consumer products. Chemical disinfection of heat-sensitive instruments and targeted disinfection of environmental surfaces are established components of hospital infection control. To avoid danger to staff, patients and the environment, prudent use as well as established safety precautions are required. New technologies and products should be evaluated with sound methods. As emerging resistant pathogens will challenge healthcare facilities in the future even more than at present, there is a need for well-designed studies addressing the role of disinfection in hospital infection control.

  19. Humidifier disinfectants, unfinished stories

    Directory of Open Access Journals (Sweden)

    Yeyong Choi

    2016-02-01

    Full Text Available Once released into the air, humidifier disinfectants became tiny nano-size particles, and resulted in chemical bronchoalveolitis. Families had lost their most beloved members, and even some of them became broken. Based on an estimate of two million potential victims who had experienced adverse effects from the use of humidifier disinfectants, we can say that what we have observed was only the tip of the iceberg. Problems of entire airways, as well as other systemic effects, should be examined, as we know these nano-size particles can irritate cell membranes and migrate into systemic circulation. The story of humidifier disinfectant is not finished yet.

  20. Environmental cleaning and disinfection.

    Science.gov (United States)

    Traverse, Michelle; Aceto, Helen

    2015-03-01

    The guidelines in this article provide veterinarians, veterinary technicians, and veterinary health care workers with an overview of evidence-based recommendations for the best practices associated with environmental cleaning and disinfection of a veterinary clinic that deals with small animals. Hospital-associated infections and the control and prevention programs necessary to alleviate them are addressed from an environmental perspective. Measures of hospital cleaning and disinfection include understanding mechanisms and types of contamination in veterinary settings, recognizing areas of potential concern, addressing appropriate decontamination techniques and selection of disinfectants, the management of potentially contaminated equipment, laundry, and waste management, and environmental surveillance strategies. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Disinfection of drinking water

    International Nuclear Information System (INIS)

    Ensenauer, P.

    1977-01-01

    Some methods for disinfecting drinking water are described, e.g. UV irradiation (optimal wavelength 210-250mm) with the advantage of constant water composition and the resulting danger of re-infection. (AJ) [de

  2. Disinfection of drinking water

    Energy Technology Data Exchange (ETDEWEB)

    Ensenauer, P

    1977-01-01

    Some methods for disinfecting drinking water are described, e.g. UV irradiation (optimal wavelength 210-250mm) with the advantage of constant water composition and the resulting danger of re-infection.

  3. Candida auris: Disinfectants and Implications for Infection Control.

    Science.gov (United States)

    Ku, Tsun S N; Walraven, Carla J; Lee, Samuel A

    2018-01-01

    Candida auris is a rapidly emerging pathogen and is able to cause severe infections with high mortality rates. It is frequently misidentified in most clinical laboratories, thus requiring more specialized identification techniques. Furthermore, several clinical isolates have been found to be multidrug resistant and there is evidence of nosocomial transmission in outbreak fashion. Appropriate infection control measures will play a major role in controlling the management and spread of this pathogen. Unfortunately, there are very few data available on the effectiveness of disinfectants against C. auris . Chlorine-based products appear to be the most effective for environmental surface disinfection. Other disinfectants, although less effective than chlorine-based products, may have a role as adjunctive disinfectants. A cleaning protocol will also need to be established as the use of disinfectants alone may not be sufficient for maximal decontamination of patient care areas. Furthermore, there are fewer data on the effectiveness of antiseptics against C. auris for patient decolonization and hand hygiene for healthcare personnel. Chlorhexidine gluconate has shown some efficacy in in vitro studies but there are reports of patients with persistent colonization despite twice daily body washes with this disinfectant. Hand hygiene using soap and water, with or without chlorhexidine gluconate, may require the subsequent use of alcohol-based hand sanitizer for maximal disinfection. Further studies will be needed to validate the currently studied disinfectants for use in real-world settings.

  4. Candida auris: Disinfectants and Implications for Infection Control

    Directory of Open Access Journals (Sweden)

    Tsun S. N. Ku

    2018-04-01

    Full Text Available Candida auris is a rapidly emerging pathogen and is able to cause severe infections with high mortality rates. It is frequently misidentified in most clinical laboratories, thus requiring more specialized identification techniques. Furthermore, several clinical isolates have been found to be multidrug resistant and there is evidence of nosocomial transmission in outbreak fashion. Appropriate infection control measures will play a major role in controlling the management and spread of this pathogen. Unfortunately, there are very few data available on the effectiveness of disinfectants against C. auris. Chlorine-based products appear to be the most effective for environmental surface disinfection. Other disinfectants, although less effective than chlorine-based products, may have a role as adjunctive disinfectants. A cleaning protocol will also need to be established as the use of disinfectants alone may not be sufficient for maximal decontamination of patient care areas. Furthermore, there are fewer data on the effectiveness of antiseptics against C. auris for patient decolonization and hand hygiene for healthcare personnel. Chlorhexidine gluconate has shown some efficacy in in vitro studies but there are reports of patients with persistent colonization despite twice daily body washes with this disinfectant. Hand hygiene using soap and water, with or without chlorhexidine gluconate, may require the subsequent use of alcohol-based hand sanitizer for maximal disinfection. Further studies will be needed to validate the currently studied disinfectants for use in real-world settings.

  5. Decontamination sheet

    International Nuclear Information System (INIS)

    Hirose, Emiko; Kanesaki, Ken.

    1995-01-01

    The decontamination sheet of the present invention is formed by applying an adhesive on one surface of a polymer sheet and releasably appending a plurality of curing sheets. In addition, perforated lines are formed on the sheet, and a decontaminating agent is incorporated in the adhesive. This can reduce the number of curing operation steps when a plurality steps of operations for radiation decontamination equipments are performed, and further, the amount of wastes of the cured sheets, and operator's exposure are reduced, as well as an efficiency of the curing operation can be improved, and propagation of contamination can be prevented. (T.M.)

  6. Recent advances in drinking water disinfection: successes and challenges.

    Science.gov (United States)

    Ngwenya, Nonhlanhla; Ncube, Esper J; Parsons, James

    2013-01-01

    Drinking water is the most important single source of human exposure to gastroenteric diseases, mainly as a result of the ingestion of microbial contaminated water. Waterborne microbial agents that pose a health risk to humans include enteropathogenic bacteria, viruses, and protozoa. Therefore, properly assessing whether these hazardous agents enter drinking water supplies, and if they do, whether they are disinfected adequately, are undoubtedly aspects critical to protecting public health. As new pathogens emerge, monitoring for relevant indicator microorganisms (e.g., process microbial indicators, fecal indicators, and index and model organisms) is crucial to ensuring drinking water safety. Another crucially important step to maintaining public health is implementing Water Safety Plans (WSPs), as is recommended by the current WHO Guidelines for Drinking Water Quality. Good WSPs include creating health-based targets that aim to reduce microbial risks and adverse health effects to which a population is exposed through drinking water. The use of disinfectants to inactivate microbial pathogens in drinking water has played a central role in reducing the incidence of waterborne diseases and is considered to be among the most successful interventions for preserving and promoting public health. Chlorine-based disinfectants are the most commonly used disinfectants and are cheap and easy to use. Free chlorine is an effective disinfectant for bacteria and viruses; however, it is not always effective against C. parvum and G. lamblia. Another limitation of using chlorination is that it produces disinfection by-products (DBPs), which pose potential health risks of their own. Currently, most drinking water regulations aggressively address DBP problems in public water distribution systems. The DBPs of most concern include the trihalomethanes (THMs), the haloacetic acids (HAAs), bromate, and chlorite. However, in the latest edition of the WHO Guidelines for Drinking Water Quality

  7. Disinfection by electrohydraulic treatment.

    Science.gov (United States)

    Allen, M; Soike, K

    1967-04-28

    Electrohydraulic treatment was applied to suspensions of Escherichia coli, spores of Bacillus subtilis var. niger, Saccharomyces cerevisiae, and bacteriophage T2 at an input energy that, in most cases, was below the energy required to sterilize. The input energy was held relatively constant for each of these microorganisms, but the capacitance and voltage were varied. Data are presented which show the degree of disinfection as a function of capacitance and voltage. In all cases, the degree of disinfection for a given input energy increases as both capacitance and voltage are lowered.

  8. UV disinfection of water

    International Nuclear Information System (INIS)

    Skipperud, E.; Johansen; Myhrstad, J.A.

    1978-01-01

    UV radiation has been found to have advantages over chloration for the disinfection of water. New regulations for dietary conditions on Norwegian ships introduced in 1974 led to increased use of UV disinfection, and this has in the following years spread to waterworks. The present article is based on a study to determine possible limitation. The nature of the injuries to the microorganisms is first discussed, together with repair mechanisms. A table is given showing the energy required for 90 and 100 percent inactivation of a number of microorganisms. Some other factors affecting UV inactivation are briefly mentioned. (JIW)

  9. Disinfection of sewage

    International Nuclear Information System (INIS)

    Arenas, J.

    1984-01-01

    Laboratory studies at IPEN and SEDAPAL have shown the effectiveness disinfection of sewage by means of ionizing radiations. A dose of 1 Kilo Gray reduces the coliforms and salmonella under the permissible levels. This method should allow to use again the liquids in the agriculture or its disposal like sea nutrient

  10. Water disinfection agents and disinfection by-products

    Science.gov (United States)

    Ilavský, J.; Barloková, D.; Kapusta, O.; Kunštek, M.

    2017-10-01

    The aim of this work is to describe factors of water quality change in the distribution network and legislative requirements in Slovakia for disinfectants and disinfection byproducts (DBPs). In the experimental part, the time dependence of the application of the chlorine dioxide and sodium hypochlorite on the formation of some by-products of disinfection for drinking water from WTP Hriňová is studied. We monitored trihalomethanes, free chlorine, chlorine dioxide and chlorites.

  11. Sewage sludges disinfection

    International Nuclear Information System (INIS)

    Alexandre, D.

    1977-01-01

    There is an hygienic risk in using biological sewage sludges for agriculture. Systematic analysis carried out on sludges samples obtained from purification plants in East and South part of France, show the almost uniform presence of pathogenic microorganisms. Some of it survive more than 9 months after soil application. Conventional process for disinfection: liming and heat are not suitable for agricultural use. On the other hand, irradiation involves no modification in structure and composition of sludges. Radiation doses required for disinfection vary according to microorganisms. If some of them are eliminated with rather light doses (200 krad) mycobacteria, viruses and eggs of worms resist to more important doses. Security dose is estimated around 1000 krad

  12. Sewage sludges disinfection

    International Nuclear Information System (INIS)

    Alexandre, D.; Gevaudan, P.P.

    1977-01-01

    There is a hygienic risk in using biological sewage sludges for agriculture. Systematic analyses carried out on sludge samples obtained from purification plants in the Eastern and Southern part of France, show the almost uniform presence of pathogenic microorganisms. Some of them survive more than nine months after application to the soil. Conventional processes for disinfection, liming and heat, make the sludge unsuitable for agricultural use. On the other hand, irradiation involves no modification of structure and composition of sludges. Radiation doses required for disinfection vary according to the type of microorganism. Some of them are eliminated at rather low doses (200 krad), but mycobacteria, viruses and eggs of worms resist to more important doses. The security dose is estimated to be approx. 1000 krad

  13. Spiral-shaped reactor for water disinfection

    KAUST Repository

    Soukane, Sofiane; Ait-Djoudi, Fariza; Naceur, Wahib M.; Ghaffour, NorEddine

    2016-01-01

    Chlorine-based processes are still widely used for water disinfection. The disinfection process for municipal water consumption is usually carried out in large tanks, specifically designed to verify several hydraulic and disinfection criteria

  14. A review on wastewater disinfection

    Directory of Open Access Journals (Sweden)

    Mohammad Mehdi Amin

    2013-01-01

    Full Text Available Changes in regulations and development of new technologies have affected the selection of alternative for treated wastewater disinfection. Disinfection is the last barrier of wastewater reclamation process to protect ecosystem safety and human health. Driving forces include water scarcity and drinking water supply, irrigation, rapid industrialization, using reclaimed water, source protection, overpopulation, and environmental protection. The safe operation of water reuse depends on effluent disinfection. Understanding the differences in inactivation mechanisms is critical to identify rate-limiting steps involved in the inactivation process as well as to develop more effective disinfection strategies. Disinfection byproducts discharged from wastewater treatment plants may impair aquatic ecosystems and downstream drinking-water quality. Numerous inorganic and organic micropollutants can undergo reactions with disinfectants. Therefore, to mitigate the adverse effects and also to enhance that efficiency, the use of alternative oxidation/disinfection systems should be evaluated as possible alternative to chlorine. This review gives a summary of the traditional, innovative, and combined disinfection alternatives and also disinfection byproducts for effluent of municipal wastewater treatment plants.

  15. Sanitizers and Disinfectants Guide. Revised

    Science.gov (United States)

    Healthy Schools Network, Inc., 2012

    2012-01-01

    Sanitizers and disinfectants can play an important role in protecting public health. They are designed to kill "pests," including infectious germs and other microorganisms such as bacteria, viruses, and fungi. Unfortunately, sanitizers and disinfectants also contain chemicals that are "pesticides." Exposure to persistent toxic…

  16. 40 CFR 141.72 - Disinfection.

    Science.gov (United States)

    2010-07-01

    ... PRIMARY DRINKING WATER REGULATIONS Filtration and Disinfection § 141.72 Disinfection. A public water... the direct influence of surface water and provides filtration treatment must provide disinfection...) Disinfection requirements for public water systems which provide filtration. Each public water system that...

  17. Disinfectant choices in veterinary practices, shelters and households : ABCD guidelines on safe and effective disinfection for feline environments

    NARCIS (Netherlands)

    Addie, Diane D; Boucraut-Baralon, Corine; Egberink, Herman; Frymus, Tadeusz; Gruffydd-Jones, Tim; Hartmann, Katrin; Horzinek, Marian C; Hosie, Margaret J; Lloret, Albert; Lutz, Hans; Marsilio, Fulvio; Pennisi, Maria Grazia; Radford, Alan D; Thiry, Etienne; Truyen, Uwe; Möstl, Karin

    OVERVIEW: Regardless of whether a pathogen is viral, bacterial, parasitic, fungal or an emerging unknown, the mainstay of infectious disease control is hygiene, and the cornerstone of good hygiene is effective disinfection. CHALLENGES AND CURRENT CHOICES: Certain pathogens present a challenge to

  18. Ultraviolet disinfection of potable water

    Energy Technology Data Exchange (ETDEWEB)

    Wolfe, R. L. [Metropolitan Water District of Southern California, Los Angeles, CA (United States)

    1990-06-15

    Because of upcoming surface and groundwater regulations regarding the control of microbiological and chemical contaminants, there is a need to evaluate the feasibility and effectiveness of ultraviolet (UV) radiation for primary disinfection of potable water supplies. Data is presented on microbicidal wavelengths of UV and distribution of energy output for low and medium-pressure arc lamps. Both systems were found to perform equally well for inactivating microorganisms, but each had distinct advantages in different applications. Approximate dosages for 90% inactivation of selected microorganisms by UV is presented in a table. Cost analysis for disinfection is presented in two tables as well as the advantages and disadvantages of UV disinfection.

  19. Ultraviolet disinfection of potable water

    International Nuclear Information System (INIS)

    Wolfe, R.L.

    1990-01-01

    Because of upcoming surface and groundwater regulations regarding the control of microbiological and chemical contaminants, there is a need to evaluate the feasibility and effectiveness of ultraviolet (UV) radiation for primary disinfection of potable water supplies. Data is presented on microbicidal wavelengths of UV and distribution of energy output for low and medium-pressure arc lamps. Both systems were found to perform equally well for inactivating microorganisms, but each had distinct advantages in different applications. Approximate dosages for 90% inactivation of selected microorganisms by UV is presented in a table. Cost analysis for disinfection is presented in two tables as well as the advantages and disadvantages of UV disinfection

  20. Surface Dielectric Barrier Discharge Jet for Skin Disinfection

    Science.gov (United States)

    Creyghton, Yves; Meijer, Rogier; Verweij, Paul; van der Zanden, Frank; Leenders, Paul

    A consortium consisting of the research institute TNO, the medical ­university and hospital St Radboud and two industrial enterprises is working on a non-thermal plasma treatment method for hand disinfection. The group is seeking for cooperation, in particular in the field of validation methods and potential ­standardization for plasma based disinfection procedures. The present paper describes technical progress in plasma source development together with initial microbiological data. Particular properties of the sheet shaped plasma volume are the possibility of treating large irregular surfaces in a short period of time, effective plasma produced species transfer to the surface together with high controllability of the nature of plasma species by means of temperature conditioning.

  1. Peracetic acid in the disinfection of a hospital water system contaminated with Legionella species.

    Science.gov (United States)

    Ditommaso, Savina; Biasin, Cinzia; Giacomuzzi, Monica; Zotti, Carla Maria; Cavanna, Alberto; Ruggenini Moiraghi, Angela

    2005-05-01

    To assess the efficacy of an alternative disinfection method for hospital water distribution systems contaminated with Legionella. Disinfection with peracetic acid was performed in a small hospital contaminated with L. pneumophila serotype 1. The disinfectant was used at concentrations of 50 ppm (first three surveillance phases) and 1,000 ppm (fourth surveillance phase) for 30 minutes. Environmental monitoring revealed that disinfection was maintained 1 week after treatment; however, levels of recontamination surpassing baseline values were detected after approximately 1 month. Comparison of water temperatures measured at the distal outlets showed a statistically significant association between temperature and bacterial load. The circulating water temperature was found to be lower in the two wards farthest away from the hot water production plant than in other wards. It was thought that the lower water temperature in the two wards promoted the bacterial growth even after disinfection. Peracetic acid may be useful in emergency situations, but does not provide definitive protection even if used monthly.

  2. A review on wastewater disinfection

    OpenAIRE

    Mohammad Mehdi Amin; Hassan Hashemi; Amir Mohammadi Bovini; Yung Tse Hung

    2013-01-01

    Changes in regulations and development of new technologies have affected the selection of alternative for treated wastewater disinfection. Disinfection is the last barrier of wastewater reclamation process to protect ecosystem safety and human health. Driving forces include water scarcity and drinking water supply, irrigation, rapid industrialization, using reclaimed water, source protection, overpopulation, and environmental protection. The safe operation of water reuse depends on effluent d...

  3. Synergistic effect of solar radiation and solar heating to disinfect drinking water sources.

    Science.gov (United States)

    Rijal, G K; Fujioka, R S

    2001-01-01

    Waterborne diseases are still common in developing countries as drinking water sources are contaminated and feasible means to reliably treat and disinfect these waters are not available. Many of these developing countries are in the tropical regions of the world where sunlight is plentiful. The objective of this study was to evaluate the effectiveness of combining solar radiation and solar heating to disinfect contaminated water using a modified Family Sol*Saver System (FSP). The non-UV transmittable cover sheet of the former FSP system was replaced with an UV transmittable plastic cover sheet to enable more wavelengths of sunlight to treat the water. Disinfection efficiency of both systems was evaluated based on reduction of the natural populations of faecal coliform, E. coli, enterococci, C. perfringens, total heterotrophic bacteria, hydrogen sulphide producing bacteria and FRNA virus. The results showed that under sunny and partly sunny conditions, water was heated to critical temperature (60 degrees C) in both the FSP systems inactivating more than 3 log (99.9%) of the concentrations of faecal coliform and E. coli to undetectable levels of heat worked synergistically to enhance the inactivation of faecal indicator bacteria. The relative log removal of indicator microorganism in the FSP treated water was total heterotrophic bacteria heat and radiation effects of sunlight were important in disinfecting water by solar units. The data indicated that direct radiation of sunlight worked synergistically with solar heating of the water to disinfect the water. Thus, effective disinfection was observed even when the water temperature did not reach 60 degrees C. Finally, the hydrogen sulphide test is a simple and reliable test that householders can use to determine whether their water had been sufficiently disinfected.

  4. Environmentally friendly disinfectant: Production, disinfectant action and efficiency

    Directory of Open Access Journals (Sweden)

    Čekerevac Milan I.

    2006-01-01

    Full Text Available Silver is a known disinfectant from ancient times, and it has been widely used for various purposes: for food and water disinfection, curing of wounds and as a universal antibiotic for a wide spectrum of diseases - until the Second World War and the discovery of penicillin. Until recently, it was assumed that silver, being a heavy metal, was toxic for humans and living beings. However, the newest research provides facts that the usage of silver, even for drinking water disinfection, is benign if it is added in small concentrations (in parts per billion. It has been shown in the newer scientific and technical literature that silver in colloidal form is a powerful (secondary disinfectant for drinking water, that it can be effectively used for the disinfection of water containers including swimming pools, installations in food industry, medicine, etc. Particularly, it has been shown that colloidal silver combined with hydrogen peroxide shows synergism having strong bactericidal and antiviral effects. The combination can be successfully used as a disinfectant in agriculture, food production and medicine. The original electrochemical process of production, the mechanism of physical-chemical reactions in that process and the mechanism of the antiseptic affect of the environmentally friendly disinfectant, based on the synergism of colloidal silver and hydrogen peroxide and the activity of electrochemically activated water, is shown. The starting solution was anolyte, obtained in electrochemical activation by water electrolysis of a highly diluted solution of K-tartarate in demineralized water (5.5-1CT4 M. The problem of electrolysis of very dilute aqueous solutions in membrane cells was particularly treated. It was shown that the efficiency of the electrolysis depends on the competition between the two processes: the rates of the processes of hydrogen and oxygen generation at the electrodes and the process of diffusion of hydrogen and hydroxyl ions

  5. [DESIDENT CaviCide a new disinfectant].

    Science.gov (United States)

    Severa, J; Klaban, V

    2009-01-01

    The properties of the new disinfection agent DESIDENT CaviCide, such as characteristics, disinfection efficiency, biological degradability and ecotoxicity are described. Also areas and forms of usage this biocidal agent are mentioned.

  6. Efficacy of chemical disinfectants for the containment of the salamander chytrid fungus Batrachochytrium salamandrivorans

    OpenAIRE

    Van Rooij, Pascale; Pasmans, Frank; Coen, Yanaïka; Martel, An

    2017-01-01

    The recently emerged chytrid fungus Batrachochytrium salamandrivorans (Bsal) causes European salamander declines. Proper hygiene protocols including disinfection procedures are crucial to prevent disease transmission. Here, the efficacy of chemical disinfectants in killing Bsal was evaluated. At all tested conditions, Biocidal (R), Chloramine-T (R), Dettol medical (R), Disolol (R), ethanol, F10 (R), Hibiscrub (R), potassium permanganate, Safe4 (R), sodium hypochlorite, and Virkon S (R), were ...

  7. Estimating retrospective exposure of household humidifier disinfectants.

    Science.gov (United States)

    Park, D U; Friesen, M C; Roh, H S; Choi, Y Y; Ahn, J J; Lim, H K; Kim, S K; Koh, D H; Jung, H J; Lee, J H; Cheong, H K; Lim, S Y; Leem, J H; Kim, Y H; Paek, D M

    2015-12-01

    We conducted a comprehensive humidifier disinfectant exposure characterization for 374 subjects with lung disease who presumed their disease was related to humidifier disinfectant use (patient group) and for 303 of their family members (family group) for an ongoing epidemiological study. We visited the homes of the registered patients to investigate disinfectant use characteristics. Probability of exposure to disinfectants was determined from the questionnaire and supporting evidence from photographs demonstrating the use of humidifier disinfectant, disinfectant purchase receipts, any residual disinfectant, and the consistency of their statements. Exposure duration was estimated as cumulative disinfectant use hours from the questionnaire. Airborne disinfectant exposure intensity (μg/m(3)) was estimated based on the disinfectant volume (ml) and frequency added to the humidifier per day, disinfectant bulk level (μg/ml), the volume of the room (m(3)) with humidifier disinfectant, and the degree of ventilation. Overall, the distribution patterns of the intensity, duration, and cumulative exposure to humidifier disinfectants for the patient group were higher than those of the family group, especially for pregnant women and patients ≤6 years old. Further study is underway to evaluate the association between the disinfectant exposures estimated here with clinically diagnosed lung disease. Retrospective exposure to household humidifier disinfectant as estimated here can be used to evaluate associations with clinically diagnosed lung disease due to the use of humidifier disinfectant in Korea. The framework, with modifications to account for dispersion and use patterns, can also be potentially adapted to assessment of other household chemical exposures. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Microbiological Efficacy Test Methods of Disinfectants

    OpenAIRE

    Şahiner, Aslı

    2015-01-01

    Disinfection process is required in every area where microbiological contamination and infection risk is present, especially in medical sector, food, veterinary and general common living areas hence many disinfectants and antiseptics are being produced for different purposes. Disinfectants are made up a large group of biocidal products. Depending on the chemical properties of active substances, targeted microorganisms may differ While some disinfectants are effective in a large spectrum, othe...

  9. UV disinfection in drinking water supplies.

    Science.gov (United States)

    Hoyer, O

    2000-01-01

    UV disinfection has become a practical and safely validatable disinfection procedure by specifying the requirements for testing and monitoring in DVGW standard W 294. A standardized biodosimetric testing procedure and monitoring with standardized UV sensors is introduced and successfully applied. On-line monitoring of irradiance can be counterchecked with handheld reference sensors and makes it possible that UV systems can be used for drinking water disinfection with the same level of confidence and safety as is conventional chemical disinfection.

  10. Can pulsed xenon ultraviolet light systems disinfect aerobic bacteria in the absence of manual disinfection?

    Science.gov (United States)

    Jinadatha, Chetan; Villamaria, Frank C; Ganachari-Mallappa, Nagaraja; Brown, Donna S; Liao, I-Chia; Stock, Eileen M; Copeland, Laurel A; Zeber, John E

    2015-04-01

    Whereas pulsed xenon-based ultraviolet light no-touch disinfection systems are being increasingly used for room disinfection after patient discharge with manual cleaning, their effectiveness in the absence of manual disinfection has not been previously evaluated. Our study indicates that pulsed xenon-based ultraviolet light systems effectively reduce aerobic bacteria in the absence of manual disinfection. These data are important for hospitals planning to adopt this technology as adjunct to routine manual disinfection. Published by Elsevier Inc.

  11. Chlamydia - CDC Fact Sheet

    Science.gov (United States)

    ... Archive STDs Home Page Bacterial Vaginosis (BV) Chlamydia Gonorrhea Genital Herpes Hepatitis HIV/AIDS & STDs Human Papillomavirus ( ... sheet Pelvic Inflammatory Disease (PID) – CDC fact sheet Gonorrhea – CDC fact sheet STDs Home Page Bacterial Vaginosis ( ...

  12. Cross-Resistance of UV- or Chlorine Dioxide-Resistant Echovirus 11 to Other Disinfectants

    Directory of Open Access Journals (Sweden)

    Qingxia Zhong

    2017-10-01

    Full Text Available The emergence of waterborne viruses with resistance to disinfection has been demonstrated in the laboratory and in the environment. Yet, the implications of such resistance for virus control remain obscure. In this study we investigate if viruses with resistance to a given disinfection method exhibit cross-resistance to other disinfectants. Chlorine dioxide (ClO2- or UV-resistant populations of echovirus 11 were exposed to five inactivating treatments (free chlorine, ClO2, UV radiation, sunlight, and heat, and the extent of cross-resistance was determined. The ClO2-resistant population exhibited cross-resistance to free chlorine, but to none of the other inactivating treatments tested. We furthermore demonstrated that ClO2 and free chlorine act by a similar mechanism, in that they mainly inhibit the binding of echovirus 11 to its host cell. As such, viruses with host binding mechanisms that can withstand ClO2 treatment were also better able to withstand oxidation by free chlorine. Conversely, the UV-resistant population was not significantly cross-resistant to any other disinfection treatment. Overall, our results indicate that viruses with resistance to multiple disinfectants exist, but that they can be controlled by inactivating methods that operate by a distinctly different mechanism. We therefore suggest to utilize two disinfection barriers that act by different mechanisms in order to control disinfection-resistant viruses.

  13. Disinfection Pilot Trial for Little Miami WWTP | Science ...

    Science.gov (United States)

    There is a serious interest growing nationally towards the use of PAA at various stages of public waste water treatment facilities; one of such use is secondary waste water treatment. MSDGC is currently interested in improving efficiency and economic aspects of waste water treatment. MSDGC requested for ORD’s support to evaluate alternative cost-effective disinfectants. This report herein is based on the data generated from the field pilot test conducted at the Little Miami Wastewater Treatment Plant. Chlorine assisted disinfection of wastewaters created the concern regarding the formation of high levels of toxic halogenated disinfection byproducts (DBPs) detrimental to aquatic life and public health. Peracetic acid is emerging as a green alternative to chlorine and claimed to have economic and social benefits. In addition, it is a relatively simple retrofit to the existing chlorine treated wastewater treatment facilities. PAA is appealed to possess a much lower aquatic toxicity profile than chlorine and decays rapidly in the environment, even if overdosed. As a result, PAA generally does not need a quenching step, such as dechlorination, reducing process complexity, sodium pollution and cost. PAA treatment does not result in the formation of chlorinated disinfection by-products such as trihalomethanes (THMs), haloacetic acids and other byproducts such as cyanide and n-Nitrosodimethylamine (NDMA).

  14. GASN sheets

    International Nuclear Information System (INIS)

    2013-12-01

    This document gathers around 50 detailed sheets which describe and present various aspects, data and information related to the nuclear sector or, more generally to energy. The following items are addressed: natural and artificial radioactive environment, evolution of energy needs in the world, radioactive wastes, which energy for France tomorrow, the consequences in France of the Chernobyl accident, ammunitions containing depleted uranium, processing and recycling of used nuclear fuel, transport of radioactive materials, seismic risk for the basic nuclear installations, radon, the precautionary principle, the issue of low doses, the EPR, the greenhouse effect, the Oklo nuclear reactors, ITER on the way towards fusion reactors, simulation and nuclear deterrence, crisis management in the nuclear field, does nuclear research put a break on the development of renewable energies by monopolizing funding, nuclear safety and security, the plutonium, generation IV reactors, comparison of different modes of electricity production, medical exposure to ionizing radiations, the control of nuclear activities, food preservation by ionization, photovoltaic solar collectors, the Polonium 210, the dismantling of nuclear installations, wind energy, desalination and nuclear reactors, from non-communication to transparency about nuclear safety, the Jules Horowitz reactor, CO 2 capture and storage, hydrogen, solar energy, the radium, the subcontractors of maintenance of the nuclear fleet, biomass, internal radio-contamination, epidemiological studies, submarine nuclear propulsion, sea energy, the Three Mile Island accident, the Chernobyl accident, the Fukushima accident, the nuclear after Fukushima

  15. An overview of water disinfection in developing countries and the potential for solar thermal water pasteurization

    Energy Technology Data Exchange (ETDEWEB)

    Burch, J.; Thomas, K.E.

    1998-01-01

    This study originated within the Solar Buildings Program at the U.S. Department of Energy. Its goal is to assess the potential for solar thermal water disinfection in developing countries. In order to assess solar thermal potential, the alternatives must be clearly understood and compared. The objectives of the study are to: (a) characterize the developing world disinfection needs and market; (b) identify competing technologies, both traditional and emerging; (c) analyze and characterize solar thermal pasteurization; (d) compare technologies on cost-effectiveness and appropriateness; and (e) identify research opportunities. Natural consequences of the study beyond these objectives include a broad knowledge of water disinfection problems and technologies, introduction of solar thermal pasteurization technologies to a broad audience, and general identification of disinfection opportunities for renewable technologies.

  16. Practical disinfection chemicals for fishing and crayfishing gear against crayfish plague transfer

    Directory of Open Access Journals (Sweden)

    Jussila J.

    2014-01-01

    Full Text Available We tested four commercial disinfectants against crayfish plague (Aphanomyces astaci spores in both aquatic solutions and with material mimicking fishing and crayfishing gear, e.g. traps, ropes, mesh, etc. The tested disinfectants were Proxitane®5:14, Proxitane®12:20, Wofasteril®E400, Virkon®S and hydrogen peroxide. The effects of the chemicals were initially tested in liquid zoospore cultures and the effective concentrations were then further tested using clean and dirty model materials (PP sheet, nylon rope, cotton fabric contaminated with A. astaci spore solutions. The disinfectants effective against infective crayfish plague spores with both clean and dirty model materials were Proxinate®5:14 (effective concentration was 30 mg·L-1 of PAA and Virkon®S (3 g·L-1, while Proxinate®12:20 (10 mg·L-1 of PAA and Wofasteril®E400 (30 mg·L-1 of PAA worked only with clean model materials. Hydrogen peroxide was not effective in the tested concentrations and conditions. Based on the results, the disinfectants most suitable for the fishing and crayfishing gear disinfection would be Proxitane®5:14 and Virkon®S, with the condition that all the gear should be thoroughly cleaned of organic matter to ensure inactivation of A. astaci spores.

  17. Characterization of Cleaning and Disinfecting Tasks and Product Use Among Hospital Occupations

    Science.gov (United States)

    Saito, Rena; Virji, M. Abbas; Henneberger, Paul K.; Humann, Michael J.; LeBouf, Ryan F.; Stanton, Marcia L.; Liang, Xiaoming; Stefaniak, Aleksandr B.

    2016-01-01

    Background Healthcare workers have an elevated prevalence of asthma and related symptoms associated with the use of cleaning/disinfecting products. The objective of this study was to identify and characterize cleaning/disinfecting tasks and products used among hospital occupations. Methods Workers from 14 occupations at five hospitals were monitored for 216 shifts, and work tasks and products used were recorded at five-minute intervals. The major chemical constituents of each product were identified from safety data sheets. Results Cleaning and disinfecting tasks were performed with a high frequency at least once per shift in many occupations. Medical equipment preparers, housekeepers, floor strippers/waxers, and endoscopy technicians spent on average 108–177 min/shift performing cleaning/disinfecting tasks. Many occupations used products containing amines and quaternary ammonium compounds for > 100 min/shift. Conclusions This analysis demonstrates that many occupations besides housekeeping incur exposures to cleaning/disinfecting products, albeit for different durations and using products containing different chemicals. PMID:25351791

  18. DISINFECTION BY-PRODUCT FORMATION BY ALTERNATIVE DISINFECTANTS AND REMOVAL BY GRANULAR ACTIVATED CARBON

    Science.gov (United States)

    The effects of the use of the alternative disinfectants on the formation of halogenated disinfection by–products (DBPs) including total organic halide, trihalomethanes, haloacetic acids, haloacetonitriles, haloketones, chloral hydrate, and chloropicrin, were examined along ...

  19. Zinc oxide nanoparticles for water disinfection

    Directory of Open Access Journals (Sweden)

    Emelita Asuncion S. Dimapilis

    2018-03-01

    Full Text Available The world faces a growing challenge for adequate clean water due to threats coming from increasing demand and decreasing supply. Although there are existing technologies for water disinfection, their limitations, particularly the formation of disinfection-by-products, have led to researches on alternative methods. Zinc oxide, an essential chemical in the rubber and pharmaceutical industries, has attracted interest as antimicrobial agent. In nanoscale, zinc oxide has shown antimicrobial properties which make its potential great for various applications. This review discusses the synthesis of zinc oxide with focus on precipitation method, its antimicrobial property and the factors affecting it, disinfection mechanisms, and the potential application to water disinfection.

  20. An environmental disinfection odyssey: evaluation of sequential interventions to improve disinfection of Clostridium difficile isolation rooms.

    Science.gov (United States)

    Sitzlar, Brett; Deshpande, Abhishek; Fertelli, Dennis; Kundrapu, Sirisha; Sethi, Ajay K; Donskey, Curtis J

    2013-05-01

    OBJECTIVE. Effective disinfection of hospital rooms after discharge of patients with Clostridium difficile infection (CDI) is necessary to prevent transmission. We evaluated the impact of sequential cleaning and disinfection interventions by culturing high-touch surfaces in CDI rooms after cleaning. DESIGN. Prospective intervention. SETTING. A Veterans Affairs hospital. INTERVENTIONS. During a 21-month period, 3 sequential tiered interventions were implemented: (1) fluorescent markers to provide monitoring and feedback on thoroughness of cleaning facility-wide, (2) addition of an automated ultraviolet radiation device for adjunctive disinfection of CDI rooms, and (3) enhanced standard disinfection of CDI rooms, including a dedicated daily disinfection team and implementation of a process requiring supervisory assessment and clearance of terminally cleaned CDI rooms. To determine the impact of the interventions, cultures were obtained from CDI rooms after cleaning and disinfection. RESULTS. The fluorescent marker intervention improved the thoroughness of cleaning of high-touch surfaces (from 47% to 81% marker removal; P disinfection, whereas during interventions periods 1, 2, and 3 the percentages of CDI rooms with positive cultures after disinfection were reduced to 57%, 35%, and 7%, respectively. CONCLUSIONS. An intervention that included formation of a dedicated daily disinfection team and implementation of a standardized process for clearing CDI rooms achieved consistent CDI room disinfection. Culturing of CDI rooms provides a valuable tool to drive improvements in environmental disinfection.

  1. Anaerobic effluent disinfection using ozone: Byproducts formation

    NARCIS (Netherlands)

    Silva, G.H.R.; Daniel, L.A.; Bruning, H.; Rulkens, W.H.

    2010-01-01

    This research was aimed at studying oxidation processes, coliform inactivation effectiveness and disinfection byproducts (DBPs) associated with the disinfection of anaerobic sanitary wastewater effluent with ozone applied at doses of 5.0, 8.0 and 10.0mg O(3)L(-1) for contact times of 5, 10 and 15

  2. Ultraviolet (UV) Disinfection for Drinking Water Systems

    Science.gov (United States)

    UV disinfection is an effective process for inactivating many microbial pathogens in water with potential to serve as stand-alone treatment or in combination with other disinfectants. USEPA provided guidance on the validation of UV reactors nearly a decade ago. Since then, lesson...

  3. Silver disinfection in water distribution systems

    Science.gov (United States)

    Silvestry Rodriguez, Nadia

    Silver was evaluated as disinfectant to maintain water quality in water distribution system. It was used to inhibit growth of two opportunistic bacteria in planktonik form and in biofilm formation in Robbins devices with stainless steel and PVC surfaces. The results of this work show that silver is a potential secondary disinfectant to be used in water distribution systems.

  4. Chemical disinfection of combined sewer overflows

    DEFF Research Database (Denmark)

    Chhetri, Ravi Kumar

    of the residual disinfectants PFA, PAA and chlorine dioxide (ClO2), and their degradation products hydrogen peroxide and chlorite, in relation to organisms in the aquatic ecosystem was studied. With the help of ecotoxicity data, a preliminary environmental risk assessment of PFA, PAA and ClO2 for CSO disinfection...

  5. Adaptive Mechanisms Underlying Microbial Resistance to Disinfectants

    Science.gov (United States)

    2016-02-01

    11775]). E.coli is a gram-negative, facultative anaerobic, and rod-shaped bacteria commonly found in warm-blooded animals . 2.1.2 Disinfectants...Nisbet, D.J. Disinfectant and Antibiotic Susceptibility Profiles of Escherichia coli O157:H7 Strains from Cattle Carcasses , Feces, and Hides and

  6. Ice sheet hydrology - a review

    Energy Technology Data Exchange (ETDEWEB)

    Jansson, Peter; Naeslund, Jens-Ove [Dept. of Physical Geography and Quaternary Geology, Stockholm Univ., Stockholm (Sweden); Rodhe, Lars [Geological Survey of Sweden, Uppsala (Sweden)

    2007-03-15

    This report summarizes the theoretical knowledge on water flow in and beneath glaciers and ice sheets and how these theories are applied in models to simulate the hydrology of ice sheets. The purpose is to present the state of knowledge and, perhaps more importantly, identify the gaps in our understanding of ice sheet hydrology. Many general concepts in hydrology and hydraulics are applicable to water flow in glaciers. However, the unique situation of having the liquid phase flowing in conduits of the solid phase of the same material, water, is not a commonly occurring phenomena. This situation means that the heat exchange between the phases and the resulting phase changes also have to be accounted for in the analysis. The fact that the solidus in the pressure-temperature dependent phase diagram of water has a negative slope provides further complications. Ice can thus melt or freeze from both temperature and pressure variations or variations in both. In order to provide details of the current understanding of water flow in conjunction with deforming ice and to provide understanding for the development of ideas and models, emphasis has been put on the mathematical treatments, which are reproduced in detail. Qualitative results corroborating theory or, perhaps more often, questioning the simplifications made in theory, are also given. The overarching problem with our knowledge of glacier hydrology is the gap between the local theories of processes and the general flow of water in glaciers and ice sheets. Water is often channelized in non-stationary conduits through the ice, features which due to their minute size relative to the size of glaciers and ice sheets are difficult to incorporate in spatially larger models. Since the dynamic response of ice sheets to global warming is becoming a key issue in, e.g. sea-level change studies, the problems of the coupling between the hydrology of an ice sheet and its dynamics is steadily gaining interest. New work is emerging

  7. Ice sheet hydrology - a review

    International Nuclear Information System (INIS)

    Jansson, Peter; Naeslund, Jens-Ove; Rodhe, Lars

    2007-03-01

    This report summarizes the theoretical knowledge on water flow in and beneath glaciers and ice sheets and how these theories are applied in models to simulate the hydrology of ice sheets. The purpose is to present the state of knowledge and, perhaps more importantly, identify the gaps in our understanding of ice sheet hydrology. Many general concepts in hydrology and hydraulics are applicable to water flow in glaciers. However, the unique situation of having the liquid phase flowing in conduits of the solid phase of the same material, water, is not a commonly occurring phenomena. This situation means that the heat exchange between the phases and the resulting phase changes also have to be accounted for in the analysis. The fact that the solidus in the pressure-temperature dependent phase diagram of water has a negative slope provides further complications. Ice can thus melt or freeze from both temperature and pressure variations or variations in both. In order to provide details of the current understanding of water flow in conjunction with deforming ice and to provide understanding for the development of ideas and models, emphasis has been put on the mathematical treatments, which are reproduced in detail. Qualitative results corroborating theory or, perhaps more often, questioning the simplifications made in theory, are also given. The overarching problem with our knowledge of glacier hydrology is the gap between the local theories of processes and the general flow of water in glaciers and ice sheets. Water is often channelized in non-stationary conduits through the ice, features which due to their minute size relative to the size of glaciers and ice sheets are difficult to incorporate in spatially larger models. Since the dynamic response of ice sheets to global warming is becoming a key issue in, e.g. sea-level change studies, the problems of the coupling between the hydrology of an ice sheet and its dynamics is steadily gaining interest. New work is emerging

  8. Cleaning and Disinfection of Bacillus cereus Biofilm.

    Science.gov (United States)

    Deal, Amanda; Klein, Dan; Lopolito, Paul; Schwarz, John Spencer

    2016-01-01

    Methodology has been evolving for the testing of disinfectants against bacterial single-species biofilms, as the difficulty of biofilm remediation continues to gain much-needed attention. Bacterial single-species biofilm contamination presents a real risk to good manufacturing practice-regulated industries. However, mixed-species biofilms and biofilms containing bacterial spores remain an even greater challenge for cleaning and disinfection. Among spore-forming microorganisms frequently encountered in pharmaceutical manufacturing areas, the spores of Bacillus cereus are often determined to be the hardest to disinfect and eradicate. One of the reasons for the low degree of susceptibility to disinfection is the ability of these spores to be encapsulated within an exopolysachharide biofilm matrix. In this series of experiments, we evaluated the disinfectant susceptibility of B. cereus biofilms relative to disassociated B. cereus spores and biofilm from a non-spore-forming species. Further, we assessed the impact that pre-cleaning has on increasing that susceptibility. Methodology has been evolving for the testing of disinfectants against bacterial single-species biofilms, as the difficulty of biofilm remediation continues to gain much-needed attention. Bacterial single-species biofilm contamination presents a real risk to good manufacturing practice-regulated industries. However, mixed-species biofilms and biofilms containing bacterial spores remain an even greater challenge for cleaning and disinfection. Among spore-forming microorganisms frequently encountered in pharmaceutical manufacturing areas, the spores of Bacillus cereus are often determined to be the hardest to disinfect and eradicate. One of the reasons for the low degree of susceptibility to disinfection is the ability of these spores to be encapsulated within an exopolysachharide biofilm matrix. In this series of experiments, we evaluated the disinfectant susceptibility of B. cereus biofilms relative to

  9. Comparison of Riboflavin and Toluidine Blue O as Photosensitizers for Photoactivated Disinfection on Endodontic and Periodontal Pathogens In Vitro.

    Science.gov (United States)

    Nielsen, Henrik Krarup; Garcia, Javier; Væth, Michael; Schlafer, Sebastian

    2015-01-01

    Photoactivated disinfection has a strong local antimicrobial effect. In the field of dentistry it is an emerging adjunct to mechanical debridement during endodontic and periodontal treatment. In the present study, we investigate the effect of photoactivated disinfection using riboflavin as a photosensitizer and blue LED light for activation, and compare it to photoactivated disinfection with the widely used combination of toluidine blue O and red light. Riboflavin is highly biocompatible and can be activated with LED lamps at hand in the dental office. To date, no reports are available on the antimicrobial effect of photoactivated disinfection using riboflavin/blue light on oral microorganisms. Planktonic cultures of eight organisms frequently isolated from periodontal and/or endodontic lesions (Aggregatibacter actinomycetemcomitans, Candida albicans, Enterococcus faecalis, Escherischia coli, Lactobacillus paracasei, Porphyromonas gingivalis, Prevotella intermedia and Propionibacterium acnes) were subjected to photoactivated disinfection with riboflavin/blue light and toluidine blue O/red light, and survival rates were determined by CFU counts. Within the limited irradiation time of one minute, photoactivated disinfection with riboflavin/blue light only resulted in minor reductions in CFU counts, whereas full kills were achieved for all organisms when using toluidine blue O/red light. The black pigmented anaerobes P. gingivalis and P. intermedia were eradicated completely by riboflavin/blue light, but also by blue light treatment alone, suggesting that endogenous chromophores acted as photosensitizers in these bacteria. On the basis of our results, riboflavin cannot be recommended as a photosensitizer used for photoactivated disinfection of periodontal or endodontic infections.

  10. 9 CFR 166.14 - Cleaning and disinfecting.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Cleaning and disinfecting. 166.14... AGRICULTURE SWINE HEALTH PROTECTION SWINE HEALTH PROTECTION General Provisions § 166.14 Cleaning and disinfecting. (a) Disinfectants to be used. Disinfection required under the regulations in this Part shall be...

  11. 9 CFR 83.7 - Shipping containers; cleaning and disinfection.

    Science.gov (United States)

    2010-01-01

    ... HEMORRHAGIC SEPTICEMIA § 83.7 Shipping containers; cleaning and disinfection. (a) All live fish that are to be... been cleaned and disinfected. (1) Cleaning and disinfection of shipping containers must be monitored by... who issues the ICI. (2) Cleaning and disinfection must be sufficient to neutralize any VHS virus to...

  12. Surface Disinfections: Present and Future

    Directory of Open Access Journals (Sweden)

    Matteo Saccucci

    2018-01-01

    Full Text Available The propagation of antibiotic resistance increases the chances of major infections for patients during hospitalization and the spread of health related diseases. Therefore finding new and effective solutions to prevent the proliferation of pathogenic microorganisms is critical, in order to protect hospital environment, such as the surfaces of biomedical devices. Modern nanotechnology has proven to be an effective countermeasure to tackle the threat of infections. On this note, recent scientific breakthroughs have demonstrated that antimicrobial nanomaterials are effective in preventing pathogens from developing resistance. Despite the ability to destroy a great deal of bacteria and control the outbreak of infections, nanomaterials present many other advantages. Moreover, it is unlikely for nanomaterials to develop resistance due to their multiple and simultaneous bactericidal mechanisms. In recent years, science has explored more complex antimicrobial coatings and nanomaterials based on graphene have shown great potential in antibacterial treatment. The purpose of this article is to deepen the discussion on the threat of infections related to surface disinfection and to assess the state of the art and potential solutions, with specific focus on disinfection procedures using nanomaterials.

  13. Sonochemical disinfection of municipal wastewater

    International Nuclear Information System (INIS)

    Antoniadis, Apostolos; Poulios, Ioannis; Nikolakaki, Eleni; Mantzavinos, Dionissios

    2007-01-01

    The application of high intensity, low frequency ultrasound for the disinfection of simulated and septic tank wastewaters is evaluated in this work. Laboratory scale experiments were conducted at 24 and 80 kHz ultrasound frequency with horn-type sonicators capable of operating in continuous and pulsed irradiation modes at nominal ultrasound intensities up to 450 W. For the experiments with simulated wastewaters, Escherichia coli were used as biological indicator of disinfection efficiency, while for the experiments with septic tank wastewaters, the total microbiological load was used. Complete elimination of E. coli could be achieved within 20-30 min of irradiation at 24 kHz and 450 W with the efficiency decreasing with decreasing intensity and frequency. Moreover, continuous irradiation was more effective than intermittent treatment based on a common energy input. Irradiation of the septic tank effluent prior to biological treatment at 24 kHz and 450 W for 30 min resulted in a three-log total microbiological load reduction, and this was nearly equal to the reduction that could be achieved during biological treatment. Bacterial cell elimination upon irradiation was irreversible as no reappearance of the microorganisms occurred after 24 h

  14. Ultraviolet disinfection of treated municipal wastewaters

    Energy Technology Data Exchange (ETDEWEB)

    Vander Laan, H; Cairns, B

    1993-12-31

    A wastewater disinfection system developed by a Canadian company, Trojan Technologies Inc., was discussed. Disinfection for pathogen reduction prior to discharge of treated municipal wastewater back into rivers and lakes has been either ignored or treated by the use of chemicals. In 1979 the first pilot ultraviolet (UV) wastewater disinfection system was established. Since then, over 500 municipal UV installations have been commissioned. The largest installation can process 212 million gallons of water per day. The advantages of UV as a disinfectant are: (1) It is more effective than chlorine. (2) There are no mutagenic/carcinogenic byproducts formed with UV. (3) No toxic chemical residuals are discharged. (4) UV is safe to both the operators and the public. (5) It is cost effective. Europe has not been as active in wastewater disinfection as has North America. One result of the absence of wastewater disinfection in Europe is that the Rhine River, for example, carries 50 million salmonella per second. Disinfection of wastewater effluents is, of course, indispensable in protecting our drinking water supply. 2 figs.

  15. CHO cell cytotoxicity and genotoxicity analyses of disinfection by-products: An updated review

    Institute of Scientific and Technical Information of China (English)

    Elizabeth D.Wagner; Michael J.Plewa

    2017-01-01

    The disinfection of drinking water is an important public health service that generates high quality,safe and palatable tap water.The disinfection of drinking water to reduce waterborne disease was an outstanding public health achievement of the 20th century.An unintended consequence is the reaction of disinfectants with natural organic matter,anthropogenic contaminants and bromide/iodide to form disinfection by-products (DBPs).A large number of DBPs are cytotoxic,neurotoxic,mutagenic,genotoxic,carcinogenic and teratogenic.Epidemiological studies demonstrated low but significant associations between disinfected drinking water and adverse health effects.The distribution of DBPs in disinfected waters has been well defined by advances in high precision analytical chemistry.Progress in the analytical biology and toxicology of DBPs has been forthcoming.The objective of this review was to provide a detailed presentation of the methodology for the quantitative,comparative analyses on the induction of cytotoxicity and genotoxicity of 103 DBPs using an identical analytical biological platform and endpoints.A single Chinese hamster ovary cell line was employed in the assays.The data presented are derived from papers published in the literature as well as additional new data and represent the largest direct quantitative comparison on the toxic potency of both regulated and emerging DBPs.These data may form the foundation of novel research to define the major forcing agents of DBP-mediated toxicity in disinfected water and may play an important role in achieving the goal of making safe drinking water better.

  16. Efficacy of chemical disinfectants for the containment of the salamander chytrid fungus Batrachochytrium salamandrivorans.

    Science.gov (United States)

    Van Rooij, Pascale; Pasmans, Frank; Coen, Yanaika; Martel, An

    2017-01-01

    The recently emerged chytrid fungus Batrachochytrium salamandrivorans (Bsal) causes European salamander declines. Proper hygiene protocols including disinfection procedures are crucial to prevent disease transmission. Here, the efficacy of chemical disinfectants in killing Bsal was evaluated. At all tested conditions, Biocidal®, Chloramine-T®, Dettol medical®, Disolol®, ethanol, F10®, Hibiscrub®, potassium permanganate, Safe4®, sodium hypochlorite, and Virkon S®, were effective at killing Bsal. Concentrations of 5% sodium chloride or lower, 0.01% peracetic acid and 0.001-1% copper sulphate were inactive against Bsal. None of the conditions tested for hydrogen peroxide affected Bsal viability, while it did kill Batrachochytrium dendrobatidis (Bd). For Bsal, enzymatic breakdown of hydrogen peroxide by catalases and specific morphological features (clustering of sporangia, development of new sporangia within the original sporangium), were identified as fungal factors altering susceptibility to several of the disinfectants tested. Based on the in vitro results we recommend 1% Virkon S®, 4% sodium hypochlorite and 70% ethanol for disinfecting equipment in the field, lab or captive setting, with a minimal contact time of 5 minutes for 1% Virkon S® and 1 minute for the latter disinfectants. These conditions not only efficiently target Bsal, but also Bd and Ranavirus.

  17. Efficacy of chemical disinfectants for the containment of the salamander chytrid fungus Batrachochytrium salamandrivorans.

    Directory of Open Access Journals (Sweden)

    Pascale Van Rooij

    Full Text Available The recently emerged chytrid fungus Batrachochytrium salamandrivorans (Bsal causes European salamander declines. Proper hygiene protocols including disinfection procedures are crucial to prevent disease transmission. Here, the efficacy of chemical disinfectants in killing Bsal was evaluated. At all tested conditions, Biocidal®, Chloramine-T®, Dettol medical®, Disolol®, ethanol, F10®, Hibiscrub®, potassium permanganate, Safe4®, sodium hypochlorite, and Virkon S®, were effective at killing Bsal. Concentrations of 5% sodium chloride or lower, 0.01% peracetic acid and 0.001-1% copper sulphate were inactive against Bsal. None of the conditions tested for hydrogen peroxide affected Bsal viability, while it did kill Batrachochytrium dendrobatidis (Bd. For Bsal, enzymatic breakdown of hydrogen peroxide by catalases and specific morphological features (clustering of sporangia, development of new sporangia within the original sporangium, were identified as fungal factors altering susceptibility to several of the disinfectants tested. Based on the in vitro results we recommend 1% Virkon S®, 4% sodium hypochlorite and 70% ethanol for disinfecting equipment in the field, lab or captive setting, with a minimal contact time of 5 minutes for 1% Virkon S® and 1 minute for the latter disinfectants. These conditions not only efficiently target Bsal, but also Bd and Ranavirus.

  18. Copper disinfection ban causes storm.

    Science.gov (United States)

    Lester, Alan

    2013-05-01

    Since 1 February this year, under the EU's Biocidal Products Directive, it has been illegal to sell or use water treatment systems that use elemental copper, a practice employed historically by a significant number of UK healthcare facilities to combat Legionella. Alan Lester, managing director of specialist supplier of 'environmentally-friendly' water treatment systems, Advanced Hydro, says the ban has caused 'a storm of giant proportion,' with advocates of copper ion-based treatment systems arguing that this disinfection method dates back 3,000 years to Egyptian times, making it an 'undoubtedly proven' technology. Here he explains why the ban came into force, considers why the UK's Health and Safety Executive (HSE) is seeking a derogation, looks at the ban's likely impact, and gives a personal viewpoint on the 'pros and cons' of some of the alternative treatment technologies, including a titanium dioxide-based system marketed by Advanced Hydro itself in the UK.

  19. ASSESSMENT OF THE EFFICIENCY OF DISINFECTION METHOD ...

    African Journals Online (AJOL)

    eobe

    ABSTRACT. The efficiencies of three disinfection methods namely boiling, water guard and pur purifier were assessed. ... Water is an indispensable resource for supporting life systems [2- ...... developing country context: improving decisions.

  20. Enhancement of ultraviolet water disinfection process

    African Journals Online (AJOL)

    grabi-1

    2013-05-15

    May 15, 2013 ... disinfected water distribution systems, including. Legionella .... soft agar, mixed, incubated at room temperature for 2 min and poured onto the ... The determination of a log increase methodology was employed to quantify the ...

  1. PROBIOTIC CLEANING PREPARATIONS VERSUS CHEMICAL DISINFECTANTS

    Directory of Open Access Journals (Sweden)

    W. Luepcke

    2017-12-01

    Full Text Available Probiotic detergents are increasingly used and are a real alternative for limiting the use of chemical cleaners, chemical disinfectants and antibiotics. They therefore have a great future because they contribute to animal health, to the hygienic production of food products of animal origin and to their harmlessness and to consumer health and environmental protection where they even have a beneficial effect on the microflora apart from chemical disinfectants that have a negative impact and destroy the beneficial microflora.

  2. Predictors of stethoscope disinfection among pediatric health care providers.

    Science.gov (United States)

    Muniz, Jeanette; Sethi, Rosh K V; Zaghi, Justin; Ziniel, Sonja I; Sandora, Thomas J

    2012-12-01

    Stethoscopes are contaminated with bacteria, but predictors of stethoscope disinfection frequency are unknown. We sought to describe health care provider stethoscope disinfection attitudes and practices and determine predictors of frequent disinfection. We used an anonymous online survey of nurses, nurse practitioners, and physicians at a pediatric hospital. We assessed frequency and methods of disinfection, perceptions of contamination, and barriers to disinfection. Multivariate logistic regression models were used to identify independent predictors of disinfecting after every use. One thousand four hundred one respondents completed the survey: 76% believed that infection transmission occurs via stethoscopes, but only 24% reported disinfecting after every use. In multivariate analyses, belief that infection transmission occurs via stethoscopes significantly increased the odds of disinfection after every use (odds ratio [OR], 2.06 [95% confidence interval (CI): 1.38-3.06]). The odds of disinfection after every use were significantly decreased in those who perceived the following barriers: lack of time (OR, 0.31 [95% CI: 0.18-0.54]), lack of access to disinfection material (OR, 0.41 [95% CI: 0.29-0.57]), or lack of visual reminders to disinfect (OR, 0.22 [95% CI: 0.14-0.34]). Only a minority of pediatric health care providers reported disinfecting their stethoscopes after every use. Increasing access to disinfection materials and visual reminders in health care facilities may improve stethoscope disinfection practices. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  3. When to use the emergency room - adult

    Science.gov (United States)

    ... feeling or inability to move Electric shock or lightning strike Severe burn Severe chest pain or pressure ... 2016. American College of Emergency Physicians. Urgent care fact sheet. newsroom.acep.org/fact_sheets?item=30033 . ...

  4. Ice sheet in peril

    DEFF Research Database (Denmark)

    Hvidberg, Christine Schøtt

    2016-01-01

    Earth's large ice sheets in Greenland and Antarctica are major contributors to sea level change. At present, the Greenland Ice Sheet (see the photo) is losing mass in response to climate warming in Greenland (1), but the present changes also include a long-term response to past climate transitions...

  5. Mobility Balance Sheet 2009

    International Nuclear Information System (INIS)

    Jorritsma, P.; Derriks, H.; Francke, J.; Gordijn, H.; Groot, W.; Harms, L.; Van der Loop, H.; Peer, S.; Savelberg, F.; Wouters, P.

    2009-06-01

    The Mobility Balance Sheet provides an overview of the state of the art of mobility in the Netherlands. In addition to describing the development of mobility this report also provides explanations for the growth of passenger and freight transport. Moreover, the Mobility Balance Sheet also focuses on a topical theme: the effects of economic crises on mobility. [nl

  6. Inactivation of an enterovirus by airborne disinfectants

    Science.gov (United States)

    2013-01-01

    Background The activity of airborne disinfectants on bacteria, fungi and spores has been reported. However, the issue of the virucidal effect of disinfectants spread by fogging has not been studied thoroughly. Methods A procedure has been developed to determine the virucidal activity of peracetic acid-based airborne disinfectants on a resistant non-enveloped virus poliovirus type 1. This virus was laid on a stainless carrier. The products were spread into the room by hot fogging at 55°C for 30 minutes at a concentration of 7.5 mL.m-3. Poliovirus inoculum, supplemented with 5%, heat inactivated non fat dry organic milk, were applied into the middle of the stainless steel disc and were dried under the air flow of a class II biological safety cabinet at room temperature. The Viral preparations were recovered by using flocked swabs and were titered on Vero cells using the classical Spearman-Kärber CPE reading method, the results were expressed as TCID50.ml-1. Results The infectious titer of dried poliovirus inocula was kept at 105 TCID50.mL-1 up to 150 minutes at room temperature. Dried inocula exposed to airborne peracetic acid containing disinfectants were recovered at 60 and 120 minutes post-exposition and suspended in culture medium again. The cytotoxicity of disinfectant containing medium was eliminated through gel filtration columns. A 4 log reduction of infectious titer of dried poliovirus inocula exposed to peracetic-based airborne disinfectant was obtained. Conclusion This study demonstrates that the virucidal activity of airborne disinfectants can be tested on dried poliovirus. PMID:23587047

  7. Carbon sheet pumping

    International Nuclear Information System (INIS)

    Ohyabu, N.; Sagara, A.; Kawamura, T.; Motojima, O.; Ono, T.

    1993-07-01

    A new hydrogen pumping scheme has been proposed which controls recycling of the particles for significant improvement of the energy confinement in toroidal magnetic fusion devices. In this scheme, a part of the vacuum vessel surface near the divertor is covered with carbon sheets of a large surface area. Before discharge initiation, the sheets are baked up to 700 ∼ 1000degC to remove the previously trapped hydrogen atoms. After being cooled down to below ∼ 200degC, the unsaturated carbon sheets trap high energy charge exchange hydrogen atoms effectively during a discharge and overall pumping efficiency can be as high as ∼ 50 %. (author)

  8. A practical evaluation of detergent and disinfectant solutions on ...

    African Journals Online (AJOL)

    Student01

    2012-01-06

    Jan 6, 2012 ... Nine sanitation chemical solutions: benzalkonium chloride, sodium hypochlorite, nitric ... cleaning and disinfection in reducing selected bacteria levels as required by ..... bacteria targeted during disinfection are attached to a.

  9. Basic Information about Chloramines and Drinking Water Disinfection

    Science.gov (United States)

    Chloramines are disinfectants used to treat drinking water. Chloramines are most commonly formed when ammonia is added to chlorine to treat drinking water. Chloramines provide longer-lasting disinfection as the water moves through pipes to consumers.

  10. Study and application of herbal disinfectants in China.

    Science.gov (United States)

    Chen, Zhao-Bin

    2004-12-01

    Disinfection means killing or removing pathogenic microorganisms in media to realize a harmless process. A disinfectant, which is also referred to as a disinfection medicine in relevant regulations, is the medicine used to kill microorganisms for the purpose of disinfection. The disinfectants prepared from plants (including traditional Chinese herbal medicines) and the extracts thereof are called herbal disinfectants. China has a long history of using herbal disinfectants. As early as in 533 A.D., the use of Cornel to sterilize well water was recorded in Necessary Techniques for Qi People by Jia Enxie of the Beiwei Dynasty. During the Dragon Boat Festival, people often use fumigants made of traditional Chinese herbal medicines like Chinese Atractylodes, Argy Wormwood Leaf and Red Arsenic Sulfide to smoke their houses, so as to ward off plagues and drive away evils. In fact this is now a kind of disinfection practice.

  11. [Experimental evaluation of the spraying disinfection efficiency on dental models].

    Science.gov (United States)

    Zhang, Yi; Fu, Yuan-fei; Xu, Kan

    2013-08-01

    To evaluate the disinfect effect after spraying a new kind of disinfectant on the dental plaster models. The germ-free plaster samples, which were smeared with bacteria compound including Staphylococcus aureus, Escherichia coli, Saccharomyces albicans, Streptococcus mutans and Actinomyces viscosus were sprayed with disinfectants (CaviCide) and glutaraldehyde individually. In one group(5 minutes later) and another group(15 minutes later), the colonies were counted for statistical analysis after sampling, inoculating, and culturing which were used for evaluation of disinfecting efficiency. ANOVA was performed using SPSS12.0 software package. All sample bacteria were eradicated after spraying disinfectants(CaviCide) within 5 minutes and effective bacteria control was retained after 15 minutes. There was significant difference between the disinfecting efficiency of CaviCide and glutaraldehyde. The effect of disinfection with spraying disinfectants (CaviCide) on dental models is quick and effective.

  12. Disinfection for small water supplies: a technical guide

    CSIR Research Space (South Africa)

    Solsona, F

    1990-01-01

    Full Text Available This guide will present some disinfection systems, which will be useful in supporting disinfection programmes. The description of the different systems will provide a guideline for the selection of equipment base on balancing the simplicity...

  13. Ice sheet hydrology from observations

    Energy Technology Data Exchange (ETDEWEB)

    Jansson, Peter [Dept. of Physical Geography and Quaternary Geology, Stockholm Univ-, Stockholm (Sweden)

    2010-11-15

    possible that soft beds through their ability to deform and be eroded can yield quasi-stable patterns of drainage pathways that with either erosion of critical sills or filling of temporary basins may reorganize itself periodically on time scales much shorter than the reorganization of the driving stresses for ice flow. In areas where the surface generated water (melt and rain), the basally generated fluxes dwarf the influx from the surface and hence the drainage system in such areas will be dominated by surface fluxes and variations therein. Since surface fluxes have a strong seasonal variation with no influx during winter, areas experiencing surface influx will also be subject to large seasonal variations in both flux and pressure. In addition, during the melt season, fluxes and also pressures will also vary on diurnal as well as longer time frames in response to variations in air temperature that drives melt and occurrence of precipitation events. The emerging picture of glacier drainage consists of different types of models applicable to different regimes found beneath an ice sheet (with our without surface influx, ice streams, subglacial lakes). It is not, however, clear how these systems are coupled, or even if they are. This makes it inherently difficult to assess what can be expected beneath a given sector of an ice sheet without some detailed understanding of the underlying geology (geothermal fluxes), geomorphology (possible water routing) and ice properties (cold -temperate base and ice thickness)

  14. Ice sheet hydrology from observations

    International Nuclear Information System (INIS)

    Jansson, Peter

    2010-11-01

    possible that soft beds through their ability to deform and be eroded can yield quasi-stable patterns of drainage pathways that with either erosion of critical sills or filling of temporary basins may reorganize itself periodically on time scales much shorter than the reorganization of the driving stresses for ice flow. In areas where the surface generated water (melt and rain), the basally generated fluxes dwarf the influx from the surface and hence the drainage system in such areas will be dominated by surface fluxes and variations therein. Since surface fluxes have a strong seasonal variation with no influx during winter, areas experiencing surface influx will also be subject to large seasonal variations in both flux and pressure. In addition, during the melt season, fluxes and also pressures will also vary on diurnal as well as longer time frames in response to variations in air temperature that drives melt and occurrence of precipitation events. The emerging picture of glacier drainage consists of different types of models applicable to different regimes found beneath an ice sheet (with our without surface influx, ice streams, subglacial lakes). It is not, however, clear how these systems are coupled, or even if they are. This makes it inherently difficult to assess what can be expected beneath a given sector of an ice sheet without some detailed understanding of the underlying geology (geothermal fluxes), geomorphology (possible water routing) and ice properties (cold -temperate base and ice thickness)

  15. Anesthesia Fact Sheet

    Science.gov (United States)

    ... Education About NIGMS NIGMS Home > Science Education > Anesthesia Anesthesia Tagline (Optional) Middle/Main Content Area En español ... Version (464 KB) Other Fact Sheets What is anesthesia? Anesthesia is a medical treatment that prevents patients ...

  16. Structural Biology Fact Sheet

    Science.gov (United States)

    ... NIGMS NIGMS Home > Science Education > Structural Biology Structural Biology Tagline (Optional) Middle/Main Content Area PDF Version (688 KB) Other Fact Sheets What is structural biology? Structural biology is the study of how biological ...

  17. Radiation protecting sheet

    International Nuclear Information System (INIS)

    Makiguchi, Hiroshi.

    1989-01-01

    As protection sheets used in radioactivity administration areas, a thermoplastic polyurethane composition sheet with a thickness of less 0.5 mm, solid content (ash) of less than 5% and a shore D hardness of less than 60 is used. A composite sheet with thickness of less than 0.5 mm laminated or coated with such a thermoplastic polyurethane composition as a surface layer and the thermoplastic polyurethane composition sheet applied with secondary fabrication are used. This can satisfy all of the required properties, such as draping property, abrasion resistance, high breaking strength, necking resistance, endurance strength, as well as chemical resistance and easy burnability in burning furnace. Further, by forming uneveness on the surface by means of embossing, etc. safety problems such as slippage during operation and walking can be overcome. (T.M.)

  18. Global ice sheet modeling

    International Nuclear Information System (INIS)

    Hughes, T.J.; Fastook, J.L.

    1994-05-01

    The University of Maine conducted this study for Pacific Northwest Laboratory (PNL) as part of a global climate modeling task for site characterization of the potential nuclear waste respository site at Yucca Mountain, NV. The purpose of the study was to develop a global ice sheet dynamics model that will forecast the three-dimensional configuration of global ice sheets for specific climate change scenarios. The objective of the third (final) year of the work was to produce ice sheet data for glaciation scenarios covering the next 100,000 years. This was accomplished using both the map-plane and flowband solutions of our time-dependent, finite-element gridpoint model. The theory and equations used to develop the ice sheet models are presented. Three future scenarios were simulated by the model and results are discussed

  19. 75 FR 55340 - Recovery Fact Sheet 9580.100, Mold Remediation

    Science.gov (United States)

    2010-09-10

    ...] Recovery Fact Sheet 9580.100, Mold Remediation AGENCY: Federal Emergency Management Agency, DHS. ACTION... accepting comments on Recovery Fact Sheet RP9580.100, Mold Remediation. DATES: Comments must be received by... 20472-3100. II. Background The Recovery Fact Sheet RP9580.100, Mold Remediation, identifies the expenses...

  20. 75 FR 13777 - Disaster Assistance Fact Sheet DAP9580.107, Child Care Services

    Science.gov (United States)

    2010-03-23

    ...] Disaster Assistance Fact Sheet DAP9580.107, Child Care Services AGENCY: Federal Emergency Management Agency... (FEMA) is providing notice of the availability of the final Disaster Assistance Fact Sheet DAP9580.107...'s Web site at http://www.fema.gov . You may also view a hard copy of the fact sheet at the Office of...

  1. Energy information sheets

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-07-01

    The National Energy Information Center (NEIC), as part of its mission, provides energy information and referral assistance to Federal, State, and local governments, the academic community, business and industrial organizations, and the public. The Energy Information Sheets was developed to provide general information on various aspects of fuel production, prices, consumption, and capability. Additional information on related subject matter can be found in other Energy Information Administration (EIA) publications as referenced at the end of each sheet.

  2. OPTIMAL SCHEDULING OF BOOSTER DISINFECTION IN WATER DISTRIBUTION SYSTEMS

    Science.gov (United States)

    Booster disinfection is the addition of disinfectant at locations distributed throughout a water distribution system. Such a strategy can reduce the mass of disinfectant required to maintain a detectable residual at points of consumption in the distribution system, which may lea...

  3. Studies on Disinfection By-Products and Drinking Water

    Science.gov (United States)

    Rostad, Colleen E.

    2007-01-01

    Drinking water is disinfected with chemicals to remove pathogens, such as Giardia and Cryptosproridium, and prevent waterborne diseases such as cholera and typhoid. During disinfection, by-products are formed at trace concentrations. Because some of these by-products are suspected carcinogens, drinking water utilities must maintain the effectiveness of the disinfection process while minimizing the formation of by-products.

  4. Chemical aspects of peracetic acid based wastewater disinfection ...

    African Journals Online (AJOL)

    Peracetic acid (PAA) has been studied for wastewater disinfection applications for some 30 years and has been shown to be an effective disinfectant against many indicator microbes, including bacteria, viruses, and protozoa. One of the key advantages compared to, e.g., chlorine is the lack of harmful disinfection ...

  5. 40 CFR 141.172 - Disinfection profiling and benchmarking.

    Science.gov (United States)

    2010-07-01

    ... benchmarking. 141.172 Section 141.172 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Disinfection-Systems Serving 10,000 or More People § 141.172 Disinfection profiling and benchmarking. (a... sanitary surveys conducted by the State. (c) Disinfection benchmarking. (1) Any system required to develop...

  6. Effects of some antiseptics and disinfectants on Staphylococcus ...

    African Journals Online (AJOL)

    A total of 6 antiseptics and disinfectants at varying concentrations (20% - 100%) and contact time (10-60 minutes) were tested for the efficacy in the reduction of Staphylococcus aureus isolated from the hands of volunteers. Disinfectant 1 was the most effective disinfectant being bactericidal to S. aureus at 100% ...

  7. 9 CFR 91.41 - Cleaning and disinfecting of aircraft.

    Science.gov (United States)

    2010-01-01

    ... of this chapter. The time at which the cleaning and disinfection is performed must be approved by the inspector, who will give approval only if he or she determines that the cleaning and disinfection will be... time, the inspector shall determine whether further cleaning and disinfection are necessary. The...

  8. Technical considerations during disinfection by UV

    International Nuclear Information System (INIS)

    Ekhtiarzadeh, Z.; Sadeghpur, H.

    2002-01-01

    The use of new methods for treatment of water and wastewater in the country is one the rise and therefore the theoretical and practical knowledge of the industry's engineers should increase simultaneously. Ultraviolet is one of the new technologies used both for treatment of water as well as wastewater. The UV disinfection system consists of different components such as the lamp, ballast and the lamp fixtures. Each has a specification, which should be taken into account prior to design, order and purchase. The subject of price is also among the important considerations. The article presents figures cost comparison in various sections. It does not try to either approve or reject other disinfection systems such as chlorination, but the writer believes that any method should find its own practice and conditions of use, and the disinfection system designers should opt for the best system suited to their plans and avoid limiting themselves to a single one

  9. Intracellular mechanisms of solar water disinfection

    Science.gov (United States)

    Castro-Alférez, María; Polo-López, María Inmaculada; Fernández-Ibáñez, Pilar

    2016-12-01

    Solar water disinfection (SODIS) is a zero-cost intervention measure to disinfect drinking water in areas of poor access to improved water sources, used by more than 6 million people in the world. The bactericidal action of solar radiation in water has been widely proven, nevertheless the causes for this remain still unclear. Scientific literature points out that generation of reactive oxygen species (ROS) inside microorganisms promoted by solar light absorption is the main reason. For the first time, this work reports on the experimental measurement of accumulated intracellular ROS in E. coli during solar irradiation. For this experimental achievement, a modified protocol based on the fluorescent probe dichlorodihydrofluorescein diacetate (DCFH-DA), widely used for oxidative stress in eukaryotic cells, has been tested and validated for E. coli. Our results demonstrate that ROS and their accumulated oxidative damages at intracellular level are key in solar water disinfection.

  10. Activity and action screening of selected disinfectants

    Directory of Open Access Journals (Sweden)

    Kateřina Balharová

    2006-01-01

    Full Text Available This research work is aimed to monitoring of selected disinfectants´activity in operational conditions. Hereby there have been monitored two acidic disinfectants Despon K and Mikasan D, which have had-by their producer-stated different recommended concentration. These solutions were monitored in viewpoint of their activity at different temperature, time of circulation, pH and water hardness. In this work there were measured pH of solutions in unloaded medium to be compared with pH of solutions in loaded medium and this measuring was carried out regularly each week within a one month period. During this period there was also monitored total plate count (TPC, which was stated in the dairy, where samples were taken two-times monthly. It has been found, that the disinfectants Mikasan D and Mikal 94D are effective even by high water hardness.

  11. Photoreactivation Study of Wastewater Treatment Effluent Disinfected by UV-disinfection for Water Reuse

    International Nuclear Information System (INIS)

    Yoon, C.G.; Jung, K.W.; Ham, J.H.; Jeon, J.H.

    2003-01-01

    Photoreactivation of microorganism following UV-disinfection is one of the research topics of interest in assessing the UV-disinfection performance. Apparent photoreactivation was examined under fluorescent lamp and solar radiation as well as in darkness. Total coliform, fecal coliform, and Escherichia coli were used as indicator microorganisms, and their concentration of 10~30 MPN/100mL increased to the level of 100 MPN/100mL after 24 hours, which implied that part of damaged microorganisms by UV-disinfection might be repairable with time

  12. Ultraviolet air disinfection for protection against influenza

    International Nuclear Information System (INIS)

    Riley, R.L.

    1977-01-01

    Three converging lines of evidence support the belief that it may be possible, under appropriate circumstances, to interrupt the airborne transmission of influenza by ultraviolet (UV) air disinfection. These lines of evidence are: (a) that influenza is airborne; (b) that UV irradiation of the upper air of a room can provide safe and effective disinfection of air in the lower part of the room; and (c) that epidemic spread of airborne viral infections in humans can be prevented if the population under consideration remains in the UV-protected environment

  13. Drinking water contamination and it's disinfection

    International Nuclear Information System (INIS)

    Shah, P.M.J.

    2005-01-01

    High quality water is necessary for the survival of human life. In this paper, an effort has been made to highlight the various causes of water contamination. Some of the most common impurities present in water are pathogenic microorganisms along with organize and in organize pollutants. Different treatment methods are adopted to ensure the potability of water. They include physical, chemical and ultra viable treatment along with solar disinfection etc. The adoption of a particular disinfection strategy depends on the level of treatment required and the resources available to carry out such a treatment. (author)

  14. Sensitivity to disinfection of bacterial indicator organisms for monitoring the Salmonella Enteritidis status of layer farms after cleaning and disinfection.

    Science.gov (United States)

    Dewaele, I; Ducatelle, R; Herman, L; Heyndrickx, M; De Reu, K

    2011-06-01

    The present study evaluated Escherichia coli, Enterococcus faecalis, and Enterococcus hirae as potential indicator organisms for the possible Salmonella Enteritidis (SE) presence in layer farms after cleaning and disinfection by comparing their susceptibility to disinfection. A quantitative suspension disinfection test according to European Standard EN1656 was performed using disinfection products CID20 and Virocid (both from CID Lines, Ieper, Belgium). In a preliminary test, the sensitivity to both disinfection products was compared between ATCC strains of SE, E. coli, En. faecalis, and En. hirae. The sensitivity of SE to disinfection was most comparable to that of E. coli. A second disinfection test compared the elimination of E. coli to SE ATCC strains as well as field strains. Results showed no significant effect regarding the strain (P > 0.05 for CID20 and Virocid), meaning that no difference was detected in sensitivity toward disinfection. When comparing the sensitivity in general at species level for all concentrations of disinfectant used, no significant difference was found between E. coli and SE in sensitivity to Virocid (P > 0.05). In conclusion, because of its similar response to disinfection in a suspension disinfection test, E. coli could be used as an indicator for possible Salmonella presence after cleaning and disinfection.

  15. The role of 'no-touch' automated room disinfection systems in infection prevention and control.

    Science.gov (United States)

    Otter, J A; Yezli, S; Perl, T M; Barbut, F; French, G L

    2013-01-01

    Surface contamination in hospitals is involved in the transmission of pathogens in a proportion of healthcare-associated infections. Admission to a room previously occupied by a patient colonized or infected with certain nosocomial pathogens increases the risk of acquisition by subsequent occupants; thus, there is a need to improve terminal disinfection of these patient rooms. Conventional disinfection methods may be limited by reliance on the operator to ensure appropriate selection, formulation, distribution and contact time of the agent. These problems can be reduced by the use of 'no-touch' automated room disinfection (NTD) systems. To summarize published data related to NTD systems. Pubmed searches for relevant articles. A number of NTD systems have emerged, which remove or reduce reliance on the operator to ensure distribution, contact time and process repeatability, and aim to improve the level of disinfection and thus mitigate the increased risk from the prior room occupant. Available NTD systems include hydrogen peroxide (H(2)O(2)) vapour systems, aerosolized hydrogen peroxide (aHP) and ultraviolet radiation. These systems have important differences in their active agent, delivery mechanism, efficacy, process time and ease of use. Typically, there is a trade-off between time and effectiveness among NTD systems. The choice of NTD system should be influenced by the intended application, the evidence base for effectiveness, practicalities of implementation and cost constraints. NTD systems are gaining acceptance as a useful tool for infection prevention and control. Copyright © 2012 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  16. A bacteriological study of hospital beds before and after disinfection with phenolic disinfectant

    OpenAIRE

    Denise de Andrade; Emília L. S. Angerami; Carlos Roberto Padovani

    2000-01-01

    In hospitals, one of the ways to control microbial contamination is by disinfecting the furniture used by patients. This study's main objective was to evaluate the microbiological condition of hospital mattresses before and after such disinfection, in order to identify bacteria that are epidemiologically important in nosocomial infection, such as Staphylococcus aureus and Pseudomonas aeruginosa. RODAC plates with two different culture media were used to collect specimens. Patient beds were se...

  17. A bacteriological study of hospital beds before and after disinfection with phenolic disinfectant

    Directory of Open Access Journals (Sweden)

    Andrade Denise de

    2000-01-01

    Full Text Available In hospitals, one of the ways to control microbial contamination is by disinfecting the furniture used by patients. This study's main objective was to evaluate the microbiological condition of hospital mattresses before and after such disinfection, in order to identify bacteria that are epidemiologically important in nosocomial infection, such as Staphylococcus aureus and Pseudomonas aeruginosa. RODAC plates with two different culture media were used to collect specimens. Patient beds were selected according to previously established criteria, and surface areas on the mattresses were chosen at random. From the total of 1 040 plate cultures from 52 mattresses, positive results were obtained from 500 of them (48.1%, 263 before disinfection and 237 after disinfection. Considering the selectivity of the culture media, the positivity rate was high. There were high prevalences of S. aureus both before and after mattress disinfection. The study results suggest that the usual disinfection procedures, instead of diminishing the number of microbes, merely displace them from one part of the mattress to another, and the number of microorganisms remains the same.

  18. A bacteriological study of hospital beds before and after disinfection with phenolic disinfectant

    Directory of Open Access Journals (Sweden)

    Denise de Andrade

    2000-03-01

    Full Text Available In hospitals, one of the ways to control microbial contamination is by disinfecting the furniture used by patients. This study's main objective was to evaluate the microbiological condition of hospital mattresses before and after such disinfection, in order to identify bacteria that are epidemiologically important in nosocomial infection, such as Staphylococcus aureus and Pseudomonas aeruginosa. RODAC plates with two different culture media were used to collect specimens. Patient beds were selected according to previously established criteria, and surface areas on the mattresses were chosen at random. From the total of 1 040 plate cultures from 52 mattresses, positive results were obtained from 500 of them (48.1%, 263 before disinfection and 237 after disinfection. Considering the selectivity of the culture media, the positivity rate was high. There were high prevalences of S. aureus both before and after mattress disinfection. The study results suggest that the usual disinfection procedures, instead of diminishing the number of microbes, merely displace them from one part of the mattress to another, and the number of microorganisms remains the same.

  19. Disintegration of liquid sheets

    Science.gov (United States)

    Mansour, Adel; Chigier, Norman

    1990-01-01

    The development, stability, and disintegration of liquid sheets issuing from a two-dimensional air-assisted nozzle is studied. Detailed measurements of mean drop size and velocity are made using a phase Doppler particle analyzer. Without air flow the liquid sheet converges toward the axis as a result of surface tension forces. With airflow a quasi-two-dimensional expanding spray is formed. The air flow causes small variations in sheet thickness to develop into major disturbances with the result that disruption starts before the formation of the main break-up region. In the two-dimensional variable geometry air-blast atomizer, it is shown that the air flow is responsible for the formation of large, ordered, and small chaotic 'cell' structures.

  20. Safety advice sheets

    CERN Multimedia

    HSE Unit

    2013-01-01

    You never know when you might be faced with questions such as: when/how should I dispose of a gas canister? Where can I find an inspection report? How should I handle/store/dispose of a chemical substance…?   The SI section of the DGS/SEE Group is primarily responsible for safety inspections, evaluating the safety conditions of equipment items, premises and facilities. On top of this core task, it also regularly issues “Safety Advice Sheets” on various topics, designed to be of assistance to users but also to recall and reinforce safety rules and procedures. These clear and concise sheets, complete with illustrations, are easy to display in the appropriate areas. The following safety advice sheets have been issued so far: Other sheets will be published shortly. Suggestions are welcome and should be sent to the SI section of the DGS/SEE Group. Please send enquiries to general-safety-visits.service@cern.ch.

  1. Carbon nanoparticles for solar disinfection of water.

    Science.gov (United States)

    Maddigpu, Pratap Reddy; Sawant, Bhairavi; Wanjari, Snehal; Goel, M D; Vione, Davide; Dhodapkar, Rita S; Rayalu, S

    2018-02-05

    The present manuscript deals with the application of carbon nano particles (CNP) and chitosan (CHIT) in the form of CHIT-CNP composite for the disinfection of water. The CHIT-CNP composite was prepared by the solution casting method and characterized by TEM, XRD and elemental analysis. In the present investigation we study the disinfection efficiency towards E. coli bacteria of both CNP and CHIT-CNP, under sunlight (SODIS) in identical experimental conditions. Both CNP and CHIT-CNP enhanced disinfection as compared to SODIS alone, and comparable performance was achieved when the same dose of CNP in the two materials was applied. However, the CHIT-CNP composite is in the form of a fabric and it is easier to use and handle as compared to the CNP powder, especially in rural and resource-constrained areas. Moreover the SODIS-CHIT-CNP setup, when used in a compound parabolic collector (CPC) reactor showed high bactericidal efficiency compared to SODIS alone, which is promising for practical applications. The disinfection potential of the CNP powder was compared with that of the well-known material TiO 2 Degussa P25 (DP 25 ): DP 25 gave 6-log kill of bacteria in 180min, whereas CNP produced 6-log kill in 150min. Copyright © 2017. Published by Elsevier B.V.

  2. essential oil as hatching egg disinfectant

    African Journals Online (AJOL)

    STORAGESEVER

    2010-04-26

    Apr 26, 2010 ... disinfectant for hatching egg obtained from broiler breeder flock. Oregano essential ... contamination rate, hatchability of fertile egg, body weight at 21 and 42 days, body weight gain and total feed ... successful healthy hatchlings. Several ...... Insecticidal properties of essential plant oils against the mosquito.

  3. STERILIZATION AND DISINFECTION IN A PRIVATE CLINIC

    African Journals Online (AJOL)

    Oral examination is done with a mirror and probe. The mirror is then washed under the tap water and disinfected in 'V3 sterilizing' fluid concentrate. The probe is placed in a tray with ... Protective glasses are worn additionally to the gloves and facemask, when cavity preparation. is being performed. The handpiece is wiped.

  4. USE OF FENTON'S REAGENT AS A DISINFECTANT

    Science.gov (United States)

    Combined sewage samples obtained from a wastewater treatment facility were disinfected by the Fenton's Reagent of several different compositions. The pre-settled samples contained both suspended solids (SS) and dissolved organic carbon (DOC) at concentrations of 28 and 290 mg/L,...

  5. Disinfection of dental impressions - compliance to accepted standards.

    Science.gov (United States)

    Almortadi, N; Chadwick, R G

    2010-12-18

    The responsibility of ensuring impressions have been cleaned and disinfected before dispatch to the dental laboratory lies solely with the dentist. Uncertainty of impression disinfection risks both the health of the receiving dental technician and potential repeat disinfection of an already disinfected impression with detrimental consequences for its dimensions. To ascertain, from the perspectives of dentists and dental technicians, current impression decontamination and disinfection practices with, in the case of the technicians, an estimate of the relative prevalence of contaminated voids within apparently disinfected impressions. Anonymous postal questionnaire. Dentist (n = 200) and dental technician (n = 200) potential participants, selected at random from the registers held by the General Dental Council, were invited to complete an anonymous postal questionnaire that sought to establish current practices and perceived effectiveness of impression disinfection. Questionnaire return rates of 42.1% and 31.2% were recorded for dentists and dental technicians respectively. A wide range of solutions, at different dilutions of the same product, was used by the dentists to disinfect dental impressions. 37.2% rinsed the impressions with water, and 2.6% always brushed debris away, before disinfection. 24.7% of dentists did not inform the laboratory of disinfection. Irrespective of the disinfection status of the received impressions, 50% of the responding dental technicians disinfected all impressions. 95% of them had received blood-contaminated impressions. 15% had encountered blood-filled voids upon trimming back the peripheries of impressions. 64.7% were confident that the impressions received by them had been disinfected by the dentists. Compliance with good practice is less than ideal and education in impression disinfection for both dentists and dental technicians is required to address this.

  6. Ice Sheets & Ice Cores

    DEFF Research Database (Denmark)

    Mikkelsen, Troels Bøgeholm

    Since the discovery of the Ice Ages it has been evident that Earth’s climate is liable to undergo dramatic changes. The previous climatic period known as the Last Glacial saw large oscillations in the extent of ice sheets covering the Northern hemisphere. Understanding these oscillations known....... The first part concerns time series analysis of ice core data obtained from the Greenland Ice Sheet. We analyze parts of the time series where DO-events occur using the so-called transfer operator and compare the results with time series from a simple model capable of switching by either undergoing...

  7. Energy information sheets

    Energy Technology Data Exchange (ETDEWEB)

    1993-12-02

    The National Energy Information Center (NEIC), as part of its mission, provides energy information and referral assistance to Federal, State, and local governments, the academic community, business and industrial organizations, and the general public. Written for the general public, the EIA publication Energy Information Sheets was developed to provide information on various aspects of fuel production, prices, consumption and capability. The information contained herein pertains to energy data as of December 1991. Additional information on related subject matter can be found in other EIA publications as referenced at the end of each sheet.

  8. Medical Emergencies in Goa

    Science.gov (United States)

    Saddichha, Sahoo; Saxena, Mukul Kumar

    2010-01-01

    Background: Most emergencies in Goa arise due to road traffic accidents and drowning, which have been compounded by the rise in number of recorded accidents in 2007 to be above 4000. It is believed that 11 people meet with an accident on Goa's roads every day and this is expected to rise by 10% by next year. Similar is the case with drownings and other medical emergencies. We therefore aimed to conduct a cross-sectional survey of medical emergencies and identify various types of emergencies presenting to emergency departments. Materials and Methods: Using a stratified random sampling design, all emergencies presenting to the three government hospitals in Goa, which handle 90% of all emergencies currently, were studied on specially designed data sheets in order to collect data. Emergency medical technicians (ETs) were placed in the Casualty Ward of the medical colleges and they recorded all emergencies on the data sheet. The collected data were then analyzed for stratification and mapping of emergencies. Results: GMC Hospital attended to majority of emergencies (62%), which were mainly of the nature of accidents or assaults (17%) and fever related (17%). Most emergencies were noncritical and about 1% expired. Maximum emergencies also presented from Salcette and Bardez, and occurred among young males in the age group of 19-45 years. Males were also more prone to accidents while females had pregnancies as emergencies. Conclusion: Potential emergency services need to target young males with higher concentrations required in Salcette in South Goa and Bardez in North Goa. PMID:20606921

  9. 75 FR 24740 - Recovery Fact Sheet RP9580.102, Permanent Relocation

    Science.gov (United States)

    2010-05-05

    ... DEPARTMENT OF HOMELAND SECURITY Federal Emergency Management Agency [Docket ID FEMA-2010-0028] Recovery Fact Sheet RP9580.102, Permanent Relocation AGENCY: Federal Emergency Management Agency, DHS... Management Agency (FEMA). DATES: This fact sheet is effective April 14, 2010. ADDRESSES: This final fact...

  10. 77 FR 40626 - RP9580.210, Personal Assistance Services in Shelters Fact Sheet

    Science.gov (United States)

    2012-07-10

    ... DEPARTMENT OF HOMELAND SECURITY Federal Emergency Management Agency [Docket ID FEMA-2012-0014] RP9580.210, Personal Assistance Services in Shelters Fact Sheet AGENCY: Federal Emergency Management... Management Agency (FEMA) is accepting comments on Recovery Fact Sheet RP9580.210, Personal Assistance...

  11. Collisionless current sheet equilibria

    Science.gov (United States)

    Neukirch, T.; Wilson, F.; Allanson, O.

    2018-01-01

    Current sheets are important for the structure and dynamics of many plasma systems. In space and astrophysical plasmas they play a crucial role in activity processes, for example by facilitating the release of magnetic energy via processes such as magnetic reconnection. In this contribution we will focus on collisionless plasma systems. A sensible first step in any investigation of physical processes involving current sheets is to find appropriate equilibrium solutions. The theory of collisionless plasma equilibria is well established, but over the past few years there has been a renewed interest in finding equilibrium distribution functions for collisionless current sheets with particular properties, for example for cases where the current density is parallel to the magnetic field (force-free current sheets). This interest is due to a combination of scientific curiosity and potential applications to space and astrophysical plasmas. In this paper we will give an overview of some of the recent developments, discuss their potential applications and address a number of open questions.

  12. Cholera Fact Sheet

    Science.gov (United States)

    ... news-room/fact-sheets/detail/cholera","@context":"http://schema.org","@type":"Article"}; العربية 中文 français русский español ... that includes feedback at the local level and information-sharing at the global level. Cholera cases are ...

  13. Pseudomonas - Fact Sheet

    OpenAIRE

    Public Health Agency

    2012-01-01

    Fact sheet on Pseudomonas, including:What is Pseudomonas?What infections does it cause?Who is susceptible to pseudomonas infection?How will I know if I have pseudomonas infection?How can Pseudomonas be prevented from spreading?How can I protect myself from Pseudomonas?How is Pseudomonas infection treated?

  14. NTPR Fact Sheets

    Science.gov (United States)

    History Documents US Underground Nuclear Test History Reports NTPR Radiation Exposure Reports Enewetak Atoll Cleanup Documents TRAC About Who We Are Our Values History Locations Our Leadership Director Support Center Contact Us FAQ Sheet Links Success Stories Contracts Business Opportunities Current

  15. Production (information sheets)

    NARCIS (Netherlands)

    2007-01-01

    Documentation sheets: Geo energy 2 Integrated System Approach Petroleum Production (ISAPP) The value of smartness 4 Reservoir permeability estimation from production data 6 Coupled modeling for reservoir application 8 Toward an integrated near-wellbore model 10 TNO conceptual framework for "E&P

  16. Hibernia fact sheet

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    This fact sheet gives details of the Hibernia oil field including its location, discovery date, oil company's interests in the project, the recoverable reserves of the two reservoirs, the production system used, capital costs of the project, and overall targets for Canadian benefit. Significant dates for the Hibernia project are listed. (UK)

  17. Ethanol Basics (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2015-01-01

    Ethanol is a widely-used, domestically-produced renewable fuel made from corn and other plant materials. More than 96% of gasoline sold in the United States contains ethanol. Learn more about this alternative fuel in the Ethanol Basics Fact Sheet, produced by the U.S. Department of Energy's Clean Cities program.

  18. Peracetic Acid as a Green Disinfectant for Combined Sewer ...

    Science.gov (United States)

    This cooperative research and development agreement between U.S. EPA, Solvay, MSDGC, and CB&I is evaluating the potential of PAA for disinfection of Muddy Creek CSO wastewater and comparing that with sodium hypochlorite disinfection. This presentation will document the effectiveness of sodium hypochlorite and PAA for the inactivation of E. coli in CSO wastewater using laboratory bench-scale jar tests and Muddy Creek field site studies based on the following items:•Storage, shelf life, and application of the disinfectants.•Effectiveness of the disinfectants in the inactivation of E. coli.•Formation of harmful byproducts by the disinfectants.•Operation and maintenance costs, including the cost of the disinfectant, its storage, application, and neutralizing agent for the disinfectant to maintain the Ohio EPA guideline for residual disinfectant at the discharge point. Like many cities in the USA, Cincinnati, Ohio is attempting to find the best way to meet state and federal requirements concerning combined sewer overflow (CSO) wastewater. The Muddy Creek CSO treatment facility was constructed to provide treatment for CSO Numbers 198 and 216 from the Westwood Trunk sewer. The Metropolitan Sewer District of Greater Cincinnati (MSDGC) is currently using sodium hypochlorite for disinfection in this treatment facility. Because of degradation of hypochlorite during storage and the formation of chlorinated disinfection byproducts (DBPs), MSDGC is evaluating alternat

  19. Peracetic acid for secondary effluent disinfection: a comprehensive performance assessment.

    Science.gov (United States)

    Antonelli, M; Turolla, A; Mezzanotte, V; Nurizzo, C

    2013-01-01

    The paper is a review of previous research on secondary effluent disinfection by peracetic acid (PAA) integrated with new data about the effect of a preliminary flash-mixing step. The process was studied at bench and pilot scale to assess its performance for discharge in surface water and agricultural reuse (target microorganisms: Escherichia coli and faecal coliform bacteria). The purposes of the research were: (1) determining PAA decay and disinfection kinetics as a function of operating parameters, (2) evaluating PAA suitability as a disinfectant, (3) assessing long-term disinfection efficiency, (4) investigating disinfected effluent biological toxicity on some aquatic indicator organisms (Vibrio fischeri, Daphnia magna and Selenastrum capricornutum), (5) comparing PAA with conventional disinfectants (sodium hypochlorite, UV irradiation). PAA disinfection was capable of complying with Italian regulations on reuse (10 CFU/100 mL for E. coli) and was competitive with benchmarks. No regrowth phenomena were observed, as long as needed for agricultural reuse (29 h after disinfection), even at negligible concentrations of residual disinfectant. The toxic effect of PAA on the aquatic environment was due to the residual disinfectant in the water, rather than to chemical modification of the effluent.

  20. Sunning as a technique for disinfecting stored beans

    International Nuclear Information System (INIS)

    Chinwada, P.; Giga, D.P.

    1996-01-01

    The effectiveness of sunning (solar heating) as a small farm technique for controlling the bean bruchids Zabrotes subfasciatus (Boheman) and Acanthoscelides obtectus (Say) was investigated. Bean seeds infested with mixed-stage larvae were placed on clear or black polyethylene sheets or inside polyethylene pouches with clear upper and black lower surfaces and exposed to the sun for five hours each day for 0, 3 and 5 successive days. No live insects emerged from seeds heated in the pouches while the few that emerged from seeds on the black sheets resulted in damage to less than 1% of the seeds. Of the three polyethylene systems used, the clear sheet was the least useful, while the pouches even for only 3 days, were the most effective in eliminating infestations. These studies demonstrated that effective bruchid control can be achieved with daily 5-h exposure periods of seeds for a successive 5-day duration. However, the success of the method of control may be influenced by the time of the year and prevailing environmental conditions

  1. Rubella - Fact Sheet for Parents

    Science.gov (United States)

    ... and 4 through 6 years Fact Sheet for Parents Color [2 pages] Español: Rubéola The best way ... according to the recommended schedule. Fact Sheets for Parents Diseases and the Vaccines that Prevent Them Chickenpox ...

  2. 75 FR 33821 - Recovery Fact Sheet RP9580.205, Public Assistance Funding to Public Housing Facilities

    Science.gov (United States)

    2010-06-15

    ... Emergency Management Agency (FEMA) is providing notice of the availability of the final Recovery Fact Sheet... the fact sheet at the Office of Chief Counsel, Federal Emergency Management Agency, Room 835, 500 C... DEPARTMENT OF HOMELAND SECURITY Federal Emergency Management Agency [Docket ID FEMA-2010-0034...

  3. Emerging Contaminants – Dinitrotoluene (DNT)

    Science.gov (United States)

    This fact sheet, developed by the U.S. Environmental Protection Agency’s Federal Facilities Restoration and Reuse Office (FFRRO), provides a brief summary of the emerging contaminant Dinitrotoluene (DNT) including physical and chemical properties.

  4. Laser Indirect Shock Welding of Fine Wire to Metal Sheet.

    Science.gov (United States)

    Wang, Xiao; Huang, Tao; Luo, Yapeng; Liu, Huixia

    2017-09-12

    The purpose of this paper is to present an advanced method for welding fine wire to metal sheet, namely laser indirect shock welding (LISW). This process uses silica gel as driver sheet to accelerate the metal sheet toward the wire to obtain metallurgical bonding. A series of experiments were implemented to validate the welding ability of Al sheet/Cu wire and Al sheet/Ag wire. It was found that the use of a driver sheet can maintain high surface quality of the metal sheet. With the increase of laser pulse energy, the bonding area of the sheet/wire increased and the welding interfaces were nearly flat. Energy dispersive spectroscopy (EDS) results show that the intermetallic phases were absent and a short element diffusion layer which would limit the formation of the intermetallic phases emerging at the welding interface. A tensile shear test was used to measure the mechanical strength of the welding joints. The influence of laser pulse energy on the tensile failure modes was investigated, and two failure modes, including interfacial failure and failure through the wire, were observed. The nanoindentation test results indicate that as the distance to the welding interface decreased, the microhardness increased due to the plastic deformation becoming more violent.

  5. [Control of disinfection in buildings used for poultry raising].

    Science.gov (United States)

    Maris, P

    1989-01-01

    During a 2-year survey in turkey breeding farms, it was possible to compare six disinfection procedures by monitoring 14 first disinfections following the breeding house cleaning and 14 second disinfections prior to animal return. By swabbing all the germs from asbestos concrete surfaces, we noted that in the case of first disinfection the chloramine T-based product was more effective than phenol or quaternary ammonium-aldehyde-based products. For the second disinfection, it was demonstrated that a minimal dose of 15 kg of formaldehyde was necessary for disinfection to be satisfactory; 12 to 15 kg paraformaldehyde was as effective as 40 to 60 liters of 30-35% formol for buildings, the ground surface of which covered between 1,000 and 1,300 m2.

  6. Application and study of conjunctival sac disinfectants in ophthalmic surgeries

    Directory of Open Access Journals (Sweden)

    Yan-Fei Luo

    2016-01-01

    Full Text Available Postoperative endophthalmitis is the most serious complications of ophthalmic surgeries. Conjunctival sac disinfection is currently recognized as an effectively important way to reduce the risk of endophthalmitis. At present, there are some disinfectants has been used in clinic or in the researches:mercury agent, gentamicin, povidone iodine and acid electrolytic water. All kinds of disinfectants play the role of disinfection by different ways. Povidone iodine is the most widely used conjunctival sac disinfectant. Mercurial and gentamicin have been rarely used because they pollute the environment, are easy to cause drug resistant bacteria, localized side reactions and so on. The acid electrolyte water is not used in clinic at present. With the popularization and development of the ophthalmic surgeries, the ophthalmologists have become more and more concerned about the postoperative eye comfort, the research and application of conjunctival sac disinfectant in the future will continue to be updated and developed.

  7. Surface disinfection challenges for Candida auris: an in-vitro study.

    Science.gov (United States)

    Kean, R; Sherry, L; Townsend, E; McKloud, E; Short, B; Akinbobola, A; Mackay, W G; Williams, C; Jones, B L; Ramage, G

    2018-04-01

    The emerging pathogenic multidrug-resistant yeast Candida auris is an important source of healthcare-associated infections and of growing global clinical concern. The ability of this organism to survive on surfaces and withstand environmental stressors creates a challenge for eradicating it from hospitals. A panel of C. auris clinical isolates was evaluated on different surface environments against the standard disinfectant sodium hypochlorite and high-level disinfectant peracetic acid. C. auris was shown to selectively tolerate clinically relevant concentrations of sodium hypochlorite and peracetic acid in a surface-dependent manner, which may explain its ability to successfully persist within the hospital environment. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  8. Interaction of Human Enteric Viruses with Microbial Compounds: Implication for Virus Persistence and Disinfection Treatments.

    Science.gov (United States)

    Waldman, Prunelle; Meseguer, Alba; Lucas, Françoise; Moulin, Laurent; Wurtzer, Sébastien

    2017-12-05

    Although the interaction between phages and bacteria has already been well described, it only recently emerged that human viruses also interact with bacteria in the mammalian gut. We studied whether this interaction could occur in tap water and thus confer enteric viruses protection against temperature and the classical disinfection treatments used in drinking water production. We demonstrated that the addition of lipopolysaccharide or peptidoglycan of bacterial origin to enterovirus provides thermal protection through stabilization of the viral capsid. This interaction plays a role when viruses are exposed to disinfection that targets the capsid, but less so when the virus genome is directly targeted. The interaction seems to be serotype-specific, suggesting that the capsid protein sequence could be important. The protection is linked to a direct association between viral particles and bacterial compounds as observed by microscopy. These results show that bacterial compounds present in the environment can affect virus inactivation.

  9. Transformation of pharmaceuticals during oxidation/disinfection processes in drinking water treatment.

    Science.gov (United States)

    Postigo, Cristina; Richardson, Susan D

    2014-08-30

    Pharmaceuticals are emerging contaminants of concern and are widespread in the environment. While the levels of these substances in finished drinking waters are generally considered too low for human health concern, there are now concerns about their disinfection by-products (DBPs) that can form during drinking water treatment, which in some cases have been proven to be more toxic than the parent compounds. The present manuscript reviews the transformation products of pharmaceuticals generated in water during different disinfection processes, i.e. chlorination, ozonation, chloramination, chlorine dioxide, UV, and UV/hydrogen peroxide, and the main reaction pathways taking place. Most of the findings considered for this review come from controlled laboratory studies involving reactions of pharmaceuticals with these oxidants used in drinking water treatment. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Is free halogen necessary for disinfection?

    Science.gov (United States)

    Williams, D E; Elder, E D; Worley, S D

    1988-10-01

    The principle of Le Chatelier was used in demonstrating that 3-chloro-4,4-dimethyl-2-oxazolidinone (compound 1) itself kills Staphylococcus aureus rather than the very small amount of free chlorine in hydrolysis equilibrium with compound 1. On the other hand, when the N-bromo analog of compound 1 (compound 1B) was used as the disinfectant, the mixture of combined compound 1B and free bromine formed in the hydrolysis equilibrium provided disinfection. When the hydrolysis equilibrium for 1B was suppressed to the level at which a negligible amount of free bromine remained in solution, combined compound 1B was much more efficacious than combined compound 1 at killing S. aureus.

  11. Ultraviolet light - nature's own disinfection process

    Energy Technology Data Exchange (ETDEWEB)

    Munkeberg, T [Thorolf Gregersen a/s, Oslo (Norway)

    1978-05-18

    Ultraviolet radiation from the sun is the means by which natural pollution products, as well as much of the smaller amount of pollution products produced by man, are converted and returned to the cycle of nature. Artificial ultraviolet radiation offers an optimum method for the disinfection of drinking water and can be used in the long term without undesireable effects on man or the enviromment. There is no evidence that ultraviolet irradiation leads to radiation resistant mutations of bacteria. The geometrical arrangement of ultraviolet disinfection units is described and the capacities of typical units is mentioned as being 600-800 m/sup 3/ /hr, though there is no reason why this should not be increased.

  12. Ultraviolet light - nature's own disinfection process

    International Nuclear Information System (INIS)

    Munkeberg, T.

    1978-01-01

    Ultraviolet radiation from the sun is the means by which natural pollution products, as well as much of the smaller amount of pollution products produced by man, are converted and returned to the cycle of nature. Artificial ultraviolet radiation offers an optimum method for the disinfection of drinking water and can be used in the long term without undesireable effects on man or the enviromment. There is no evidence that ultraviolet irradiation leads to radiation resistant mutations of bacteria. The geometrical arrangement of ultraviolet disinfection units is described and the capacities of typical units is mentioned as being 600-800 m 3 /hr, though there is no reason why this should not be increased. (JIW)

  13. Assessment of photoreactivation following ultraviolet light disinfection

    International Nuclear Information System (INIS)

    Kashimada, K.; Kamiko, N.; Yamamoto, K.; Ohgaki, S.

    1996-01-01

    Photoreactivation of microorganisms following UV disinfection is one of the research topics of interest in assessing the performance of UV disinfection, because there is little consensus on how the visible light intensity relates to the photoreactivation rate and the maximum survival in wastewater treatment processes. Apparent photoreactivation by a fluorescent lamp was observed in case of indicator bacteria (heterotrophic bacteria, coliform bacteria, fecal coliforms) in raw sewage, but not E. coli B and E. coli K12 A/λ(F+). Inactivation of fecal coliform was observed simultaneously during photoreactivation process by sunlight. Dose rate at 360 nm wave length as visible light intensity showed that it was a useful indicator for assessing the photoreactivation rate and the maximum survival when photoreactivation took place by both fluorescent lamp and sunlight. The model for photoreactivation was developed. The photoreactivation rate increased with increasing visible light intensity at 360 nm. However, the maximum survival value may not be affected by visible light intensity. (author)

  14. Quantification of air plasma chemistry for surface disinfection

    International Nuclear Information System (INIS)

    Pavlovich, Matthew J; Clark, Douglas S; Graves, David B

    2014-01-01

    Atmospheric-pressure air plasmas, created by a variety of discharges, are promising sources of reactive species for the emerging field of plasma biotechnology because of their convenience and ability to operate at ambient conditions. One biological application of ambient-air plasma is microbial disinfection, and the ability of air plasmas to decontaminate both solid surfaces and liquid volumes has been thoroughly established in the literature. However, the mechanism of disinfection and which reactive species most strongly correlate with antimicrobial effects are still not well understood. We describe quantitative gas-phase measurements of plasma chemistry via infrared spectroscopy in confined volumes, focusing on air plasma generated via surface micro-discharge (SMD). Previously, it has been shown that gaseous chemistry is highly sensitive to operating conditions, and the measurements we describe here extend those findings. We quantify the gaseous concentrations of ozone (O 3 ) and nitrogen oxides (NO and NO 2 , or NO x ) throughout the established ‘regimes’ for SMD air plasma chemistry: the low-power, ozone-dominated mode; the high-power, nitrogen oxides-dominated mode; and the intermediate, unstable transition region. The results presented here are in good agreement with previously published experimental studies of aqueous chemistry and parameterized models of gaseous chemistry. The principal finding of the present study is the correlation of bacterial inactivation on dry surfaces with gaseous chemistry across these time and power regimes. Bacterial decontamination is most effective in ‘NO x mode’ and less effective in ‘ozone mode’, with the weakest antibacterial effects in the transition region. Our results underscore the dynamic nature of air plasma chemistry and the importance of careful chemical characterization of plasma devices intended for biological applications. (paper)

  15. Quantification of air plasma chemistry for surface disinfection

    Science.gov (United States)

    Pavlovich, Matthew J.; Clark, Douglas S.; Graves, David B.

    2014-12-01

    Atmospheric-pressure air plasmas, created by a variety of discharges, are promising sources of reactive species for the emerging field of plasma biotechnology because of their convenience and ability to operate at ambient conditions. One biological application of ambient-air plasma is microbial disinfection, and the ability of air plasmas to decontaminate both solid surfaces and liquid volumes has been thoroughly established in the literature. However, the mechanism of disinfection and which reactive species most strongly correlate with antimicrobial effects are still not well understood. We describe quantitative gas-phase measurements of plasma chemistry via infrared spectroscopy in confined volumes, focusing on air plasma generated via surface micro-discharge (SMD). Previously, it has been shown that gaseous chemistry is highly sensitive to operating conditions, and the measurements we describe here extend those findings. We quantify the gaseous concentrations of ozone (O3) and nitrogen oxides (NO and NO2, or NOx) throughout the established ‘regimes’ for SMD air plasma chemistry: the low-power, ozone-dominated mode; the high-power, nitrogen oxides-dominated mode; and the intermediate, unstable transition region. The results presented here are in good agreement with previously published experimental studies of aqueous chemistry and parameterized models of gaseous chemistry. The principal finding of the present study is the correlation of bacterial inactivation on dry surfaces with gaseous chemistry across these time and power regimes. Bacterial decontamination is most effective in ‘NOx mode’ and less effective in ‘ozone mode’, with the weakest antibacterial effects in the transition region. Our results underscore the dynamic nature of air plasma chemistry and the importance of careful chemical characterization of plasma devices intended for biological applications.

  16. UV DISINFECTION GUIDANCE MANUAL FOR THE ...

    Science.gov (United States)

    Provides technical information on selection, design and operation of UV systems; provides regulatory agencies with guidance and the necessary tools to assess UV systems at the design, start-up, and routine operation phase; provides manufacturers with the testing and performance standards for UV components and systems for treating drinking water. Provide guidance to water systems, regulators and manufacturers on UV disinfection of drinking water.

  17. Role of disinfection in the Infection Prevention Multibarrier System

    OpenAIRE

    Kramer, Axel

    2007-01-01

    The role of disinfection in infection prevention has been analyzed over the past 50 years both in the form of benefit-risk evaluations as well as in an epidemiological sense. This has served as the basis for not only national and international guidelines and recommendations, but has also created the legal and normative framework for regulation of infection control (and hence of disinfection) in numerous and acts and ordinances. Likewise, today the efficacy of disinfection measures, user safet...

  18. Disinfectant effect of Methylated Ethanol against Listeria species

    OpenAIRE

    Y Yakubu; M D Salihu; O O Faleke; M B Abubakar; A A Magaji,A U Junaidu

    2012-01-01

    This study was carried out in order to determine the disinfectant effect of Methylated spirit® (95% methanol and 5% ethanol) as a teat dip against Listeria species. Hand milking was employed to collect 576 (288 x 2) raw milk samples from different lactating cows within Sokoto metropolis (Nigeria). 288 samples were collected before disinfecting the udder teats with Methylated spirit®, while the other 288 were collected after disinfection with Methylated spirit®. The ...

  19. Efficacy of a variety of disinfectants against Listeria spp.

    OpenAIRE

    Best, M; Kennedy, M E; Coates, F

    1990-01-01

    The efficacy of 14 disinfectants against Listeria innocua and two strains of Listeria monocytogenes in the presence of organic matter was studied. Quantitative efficacy tests were used. Many of the disinfectants tested were not as effective on Listeria spp. when the test organisms were dried onto the surface of steel disks (carrier tests) as they were when the organisms were placed in suspension (suspension test). The presence of whole serum and milk (2% fat) further reduced the disinfectant ...

  20. Bacterial Spores Survive Treatment with Commercial Sterilants and Disinfectants

    OpenAIRE

    Sagripanti, Jose-Luis; Bonifacino, Aylin

    1999-01-01

    This study compared the activity of commercial liquid sterilants and disinfectants on Bacillus subtilis spores deposited on three types of devices made of noncorrodible, corrodible, or polymeric material. Products like Renalin, Exspor, Wavicide-01, Cidexplus, and cupric ascorbate were tested under conditions specified for liquid sterilization. These products, at the shorter times indicated for disinfection, and popular disinfectants, like Clorox, Cavicide, and Lysol were also studied. Data ob...

  1. Development of the electrical discharge method for water disinfection

    International Nuclear Information System (INIS)

    Vojtenko, L.M.; Kononov, O.V.; Starchik, P.D.; Samojlenko, L.S.; Stavs'ka, S.S.

    1995-01-01

    Studies of processes of bacterially polluted water disinfection by the method of pulse electrical discharge in water are presented. The studies was performed to improve the disinfection technology. Main attention was concentrated to clear up effect of discharge instability on the disinfection. An influence of the shape and sizes of electrodes on repeatability of discharges was also investigated. It was found that salts solved in water greatly influence ultraviolet radiation absorption coefficients

  2. Film sheet cassette

    International Nuclear Information System (INIS)

    1981-01-01

    A novel film sheet cassette is described for handling CAT photographic films under daylight conditions and facilitating their imaging. A detailed description of the design and operation of the cassette is given together with appropriate illustrations. The resulting cassette is a low-cost unit which is easily constructed and yet provides a sure light-tight seal for the interior contents of the cassette. The individual resilient fingers on the light-trap permit the ready removal of the slide plate for taking pictures. The stippled, non-electrostatic surface of the pressure plate ensures an air layer and free slidability of the film for removal and withdrawal of the film sheet. The advantage of the daylight system is that a darkroom need not be used for inserting and removing the film in and out of the cassette resulting in a considerable time saving. (U.K.)

  3. Clean Cities Fact Sheet

    Energy Technology Data Exchange (ETDEWEB)

    2004-01-01

    This fact sheet explains the Clean Cities Program and provides contact information for all coalitions and regional offices. It answers key questions such as: What is the Clean Cities Program? What are alternative fuels? How does the Clean Cities Program work? What sort of assistance does Clean Cities offer? What has Clean Cities accomplished? What is Clean Cities International? and Where can I find more information?

  4. Information sheets on energy

    International Nuclear Information System (INIS)

    2004-01-01

    These sheets, presented by the Cea, bring some information, in the energy domain, on the following topics: the world energy demand and the energy policy in France and in Europe, the part of the nuclear power in the energy of the future, the greenhouse gases emissions and the fight against the greenhouse effect, the carbon dioxide storage cost and the hydrogen economy. (A.L.B.)

  5. Biomolecular Science (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2012-04-01

    A brief fact sheet about NREL Photobiology and Biomolecular Science. The research goal of NREL's Biomolecular Science is to enable cost-competitive advanced lignocellulosic biofuels production by understanding the science critical for overcoming biomass recalcitrance and developing new product and product intermediate pathways. NREL's Photobiology focuses on understanding the capture of solar energy in photosynthetic systems and its use in converting carbon dioxide and water directly into hydrogen and advanced biofuels.

  6. Spiral-shaped reactor for water disinfection

    KAUST Repository

    Soukane, Sofiane

    2016-04-20

    Chlorine-based processes are still widely used for water disinfection. The disinfection process for municipal water consumption is usually carried out in large tanks, specifically designed to verify several hydraulic and disinfection criteria. The hydrodynamic behavior of contact tanks of different shapes, each with an approximate total volume of 50,000 m3, was analyzed by solving turbulent momentum transport equations with a computational fluid dynamics code, namely ANSYS fluent. Numerical experiments of a tracer pulse were performed for each design to generate flow through curves and investigate species residence time distribution for different inlet flow rates, ranging from 3 to 12 m3 s−1. A new nature-inspired Conch tank design whose shape follows an Archimedean spiral was then developed. The spiral design is shown to strongly outperform the other tanks’ designs for all the selected plug flow criteria with an enhancement in efficiency, less short circuiting, and an order of magnitude improvement in mixing and dispersion. Moreover, following the intensification philosophy, after 50% reduction in its size, the new design retains its properties and still gives far better results than the classical shapes.

  7. Biological Treatment of Water Disinfection Byproducts using ...

    Science.gov (United States)

    Major disinfection by-products (DBPs) from the chlorination process of drinking water include trihalomethanes (THMs) and haloacetic acides (HAA5). THMs mainly consist of chloroform, and other harsh chemicals. Prolonged consumptions of drinking water containing high levels of THMs has been linked with diseases of the liver, kidneys, bladder, or central nervous system and may increase likelihood of cancer. A risk also exists for THMs exposure via inhalation while showering, bathing or washing clothes and dishes. Due to these risks, the U.S. EPA regulate THMs content in drinking water. This research investigates biological degradation of THM using chloroform as a model compound. The study aims to decrease possible risks of THMs through filtration. Throughout this year’s presentations, there is a common theme of health and safety concerns. UC researchers are working hard to clean water ways of naturally occurring contaminates as well as man-made toxins found in our waterways. The significance of these presentations translates into the promise of safer environments, and more importantly saved lives, as UC’s faculty continues to produce real-world solutions to problems threatening the world around us. A biotech process has been developed and demonstrated that effectively remove and treat volatile disinfection by-products from drinking water. The process strips low concentration disinfection by-products, such as trihalomethanes, that are formed during the chlori

  8. Evaluation of toothbrush disinfection via different methods

    Directory of Open Access Journals (Sweden)

    Adil BASMAN

    2016-01-01

    Full Text Available The aim of this study was to compare the efficacy of using a dishwasher or different chemical agents, including 0.12% chlorhexidine gluconate, 2% sodium hypochlorite (NaOCl, a mouthrinse containing essential oils and alcohol, and 50% white vinegar, for toothbrush disinfection. Sixty volunteers were divided into five experimental groups and one control group (n = 10. Participants brushed their teeth using toothbrushes with standard bristles, and they disinfected the toothbrushes according to instructed methods. Bacterial contamination of the toothbrushes was compared between the experimental groups and the control group. Data were analyzed by Kruskal–Wallis and Duncan's multiple range tests, with 95% confidence intervals for multiple comparisons. Bacterial contamination of toothbrushes from individuals in the experimental groups differed from those in the control group (p < 0.05. The most effective method for elimination of all tested bacterial species was 50% white vinegar, followed in order by 2% NaOCl, mouthrinse containing essential oils and alcohol, 0.12% chlorhexidine gluconate, dishwasher use, and tap water (control. The results of this study show that the most effective method for disinfecting toothbrushes was submersion in 50% white vinegar, which is cost-effective, easy to access, and appropriate for household use.

  9. Sheet pinch devices

    International Nuclear Information System (INIS)

    Anderson, O.A.; Baker, W.R.; Ise, J. Jr.; Kunkel, W.B.; Pyle, R.V.; Stone, J.M.

    1958-01-01

    Three types of sheet-like discharges are being studied at Berkeley. The first of these, which has been given the name 'Triax', consists of a cylindrical plasma sleeve contained between two coaxial conducting cylinders A theoretical analysis of the stability of the cylindrical sheet plasma predicts the existence of a 'sausage-mode' instability which is, however, expected to grow more slowly than in the case of the unstabilized linear pinch (by the ratio of the radial dimensions). The second pinch device employs a disk shaped discharge with radial current guided between flat metal plates, this configuration being identical to that of the flat hydromagnetic capacitor without external magnetic field. A significant feature of these configurations is the absence of a plasma edge, i.e., there are no regions of sharply curved magnetic field lines anywhere in these discharges. The importance of this fact for stability is not yet fully investigated theoretically. As a third configuration a rectangular, flat pinch tube has been constructed, and the behaviour of a flat plasma sheet with edges is being studied experimentally

  10. Bacterial spores survive treatment with commercial sterilants and disinfectants.

    Science.gov (United States)

    Sagripanti, J L; Bonifacino, A

    1999-09-01

    This study compared the activity of commercial liquid sterilants and disinfectants on Bacillus subtilis spores deposited on three types of devices made of noncorrodible, corrodible, or polymeric material. Products like Renalin, Exspor, Wavicide-01, Cidexplus, and cupric ascorbate were tested under conditions specified for liquid sterilization. These products, at the shorter times indicated for disinfection, and popular disinfectants, like Clorox, Cavicide, and Lysol were also studied. Data obtained with a sensitive and quantitative test suggest that commercial liquid sterilants and disinfectants are less effective on contaminated surfaces than generally acknowledged.

  11. Less skin irritation from alcohol-based disinfectant than from detergent used for hand disinfection

    DEFF Research Database (Denmark)

    Pedersen, L K; Held, E; Johansen, J D

    2005-01-01

    and forearms of 17 healthy volunteers. A control area was included. After 4 weeks an SLS patch was applied to each area. Irritant reactions were quantified with a visual score recording and measurements of transepidermal water loss (TEWL) and skin colour were performed on days 1, 5, 11, 38 and 40. RESULTS...... was found on the disinfectant-treated area compared with the control area and detergent area, and a similar trend was found for TEWL, although it was not statistically significant. CONCLUSION: Alcohol-based disinfectant caused less visible skin irritation and less skin barrier disruption than the use...

  12. Pre-LGM Northern Hemisphere ice sheet topography

    Directory of Open Access Journals (Sweden)

    J. Kleman

    2013-10-01

    Full Text Available We here reconstruct the paleotopography of Northern Hemisphere ice sheets during the glacial maxima of marine isotope stages (MIS 5b and 4.We employ a combined approach, blending geologically based reconstruction and numerical modeling, to arrive at probable ice sheet extents and topographies for each of these two time slices. For a physically based 3-D calculation based on geologically derived 2-D constraints, we use the University of Maine Ice Sheet Model (UMISM to calculate ice sheet thickness and topography. The approach and ice sheet modeling strategy is designed to provide robust data sets of sufficient resolution for atmospheric circulation experiments for these previously elusive time periods. Two tunable parameters, a temperature scaling function applied to a spliced Vostok–GRIP record, and spatial adjustment of the climatic pole position, were employed iteratively to achieve a good fit to geological constraints where such were available. The model credibly reproduces the first-order pattern of size and location of geologically indicated ice sheets during marine isotope stages (MIS 5b (86.2 kyr model age and 4 (64 kyr model age. From the interglacial state of two north–south obstacles to atmospheric circulation (Rocky Mountains and Greenland, by MIS 5b the emergence of combined Quebec–central Arctic and Scandinavian–Barents-Kara ice sheets had increased the number of such highland obstacles to four. The number of major ice sheets remained constant through MIS 4, but the merging of the Cordilleran and the proto-Laurentide Ice Sheet produced a single continent-wide North American ice sheet at the LGM.

  13. Dense sheet Z-pinches

    International Nuclear Information System (INIS)

    Tetsu, Miyamoto

    1999-01-01

    The steady state and quasi-steady processes of infinite- and finite-width sheet z-pinches are studied. The relations corresponding to the Bennett relation and Pease-Braginskii current of cylindrical fiber z-pinches depend on a geometrical factor in the sheet z-pinches. The finite-width sheet z-pinch is approximated by a segment of infinite-width sheet z-pinch, if it is wide enough, and corresponds to a number of (width/thickness) times fiber z-pinch plasmas of the diameter that equals the sheet thickness. If the sheet current equals this number times the fiber current, the plasma created in the sheet z-pinches is as dense as in the fiber z-pinches. The total energy of plasma and magnetic field per unit mass is approximately equal in both pinches. Quasi-static transient processes are different in several aspects from the fiber z-pinch. No radiation collapse occurs in the sheet z-pinch. The stability is improved in the sheet z-pinches. The fusion criterions and the experimental arrangements to produce the sheet z-pinches are also discussed. (author)

  14. Disinfectant Products Fact Sheet. To assess the risks for the consumer

    NARCIS (Netherlands)

    Prud'homme de Lodder LCH; Bremmer HJ; Pelgrom SMGJ; Park MVDZ; Engelen JGM van; SIR

    2006-01-01

    Exposure to compounds in consumer products can be assessed using the computer program ConsExpo (Consumer Exposure). Given the huge number of consumer products, it is not possible to calculate the exposure for each separate product, so a limited number of groups containing similar products are

  15. Perforation of metal sheets

    DEFF Research Database (Denmark)

    Steenstrup, Jens Erik

    simulation is focused on the sheet deformation. However, the effect on the tool and press is included. The process model is based on the upper bound analysis in order to predict the force progress and hole characteristics etc. Parameter analyses are divided into two groups, simulation and experimental tests......The main purposes of this project are:1. Development of a dynamic model for the piercing and performation process2. Analyses of the main parameters3. Establishing demands for process improvements4. Expansion of the existing parameter limitsThe literature survey describes the process influence...

  16. MUTAGENICITY AND DISINFECTION BY-PRODUCTS IN SURFACE DRINKING WATER DISINFECTED WITH PERACETIC ACID

    Science.gov (United States)

    The aims of this research were to study the influence of peracetic acid (PAA) on the formation of mutagens in surface waters used for human consumption and to assess its potential application for the disinfection of drinking water. The results obtained using PAA were compared to ...

  17. 21 CFR 880.6890 - General purpose disinfectants.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use... disinfectant is a germicide intended to process noncritical medical devices and equipment surfaces. A general... prior to terminal sterilization or high level disinfection. Noncritical medical devices make only...

  18. [Scanning electron microscope study of chemically disinfected endodontic files].

    Science.gov (United States)

    Navarro, G; Mateos, M; Navarro, J L; Canalda, C

    1991-01-01

    Forty stainless steel endodontic files were observed at scanning electron microscopy after being subjected to ten disinfection cycles of 10 minutes each one, immersed in different chemical disinfectants. Corrosion was not observed on the surface of the files in circumstances that this study was made.

  19. Ozone reactions with indoor materials during building disinfection

    DEFF Research Database (Denmark)

    Poppendieck, D.; Hubbard, H.; Ward, M.

    2007-01-01

    , and particularly after several hours of disinfection, surface reaction resistance dominated the overall resistance to ozone deposition for nearly all materials. Total building disinfection by-products (all carbonyls) were quantified per unit area of each material for the experimental period. Paper, office...... partition, and medium density fiberboard each released greater than 38 mg m(-2) of by-products....

  20. The antimicrobial activities of some commonly used disinfectants on ...

    African Journals Online (AJOL)

    The disinfectants; SavlonR, JikR, Methylated spirit and kerosene were observed for their inhibitory activities on Bacillus subtilis, Pseudomonas aeruginosa and Candida albicans. This was done by measuring the zone of inhibition of the disinfectants on the tested organisms. The results showed that Savlon was very effective ...

  1. Microbial contamination of disinfectant solutions in some health care ...

    African Journals Online (AJOL)

    Commonly used disinfectants in some health institutions in three major towns of northern Nigeria were examined for presence of bacteria contamination. For each disinfectant, stock, freshly diluted and left-over of used diluted samples were analyzed. All the stock samples were free of bacteria contaminants while 52.17% of ...

  2. HIGH-RATE DISINFECTION TECHNIQUES FOR COMBIND SEWER OVERFLOW

    Science.gov (United States)

    This paper presents high-rate disinfection technologies for combined sewer overflow (CSO). The high-rate disinfection technologies of interest are: chlorination/dechlorination, ultraviolet light irradiation (UV), chlorine dioxide (ClO2 ), ozone (O3), peracetic acid (CH3COOOH )...

  3. Peracetic Acid as a Green Disinfectant for Combined Sewer Overflows

    Science.gov (United States)

    This cooperative research and development agreement between U.S. EPA, Solvay, MSDGC, and CB&I is evaluating the potential of PAA for disinfection of Muddy Creek CSO wastewater and comparing that with sodium hypochlorite disinfection. This presentation will document the effectiven...

  4. Disinfectant effect of Methylated Ethanol against Listeria species

    Directory of Open Access Journals (Sweden)

    Y Yakubu

    2012-04-01

    Full Text Available This study was carried out in order to determine the disinfectant effect of Methylated spirit® (95% methanol and 5% ethanol as a teat dip against Listeria species. Hand milking was employed to collect 576 (288 x 2 raw milk samples from different lactating cows within Sokoto metropolis (Nigeria. 288 samples were collected before disinfecting the udder teats with Methylated spirit®, while the other 288 were collected after disinfection with Methylated spirit®. The samples were analyzed using selective culture and isolation technique in which the 288 samples collected before disinfection, 114 (39.6% were positive for Listeria species. Among the positive samples 44 (38.6% were Listeria innocua, 16 (14.0% Listeria ivanovii, 36 (31.6% Listeria monocytogenes, 11 (9.6% Listeria welshimeri and 7 (6.1% Listeria seeligeri, while none of the 288 samples collected after disinfection was positive. The study has shown high prevalence of Listeria species in milk collected without washing/disinfecting the teats and has also established the sensitivity of Listeria species to methylated ethanol which can be used as dip for disinfecting udder teats before milking in order to prevent contamination with Listeria species and other methylated spirit-sensitive organisms. This study is essential to educate Fulani herdsmen and other milk handlers on the importance of disinfecting udder teats before milking. [Vet. World 2012; 5(2.000: 91-93

  5. Evaluation of hospital disinfection as a means of controlling endemic ...

    African Journals Online (AJOL)

    Evaluation of hospital environment disinfection as a means of controlling endemic nosocomial pathogens in a University Teaching Hospital in Nigeria was evaluated. Disinfectant used in the Hospital was collected from the Infection Control unit and prepared in different concentrations. The isolated bacterial species from the ...

  6. Nanomaterial Case Study: Nanoscale Silver in Disinfectant Spray (Final Report)

    Science.gov (United States)

    EPA announced the release of the final report, Nanomaterial Case Study: Nanoscale Silver in Disinfectant Spray. This report represents a case study of engineered nanoscale silver (nano-Ag), focusing on the specific example of nano-Ag as possibly used in disinfectant spr...

  7. Disinfection studies of Nahar (Mesua ferrea) seed kernel oil using ...

    African Journals Online (AJOL)

    GREGORY

    2011-12-16

    Dec 16, 2011 ... with a k value of -0.040. Key words: Nahar (Mesua ferrea) seed kernel oil, extraction, gum Arabic, disinfection, kinetics. INTRODUCTION. Disinfection plays a key role in the reclamation and reuse of wastewater for eliminating infectious diseases, this, in part, augments domestic water supply and decreases ...

  8. Sewage disinfection towards protection of drinking water resources.

    Science.gov (United States)

    Kolch, A

    2000-01-01

    Wastewater applied in agriculture for irrigation could replace the use of natural drinking-water resources. With respect to high concentrations of human pathogens wastewater has to be disinfected prior to use. This paper introduces disinfection methods with emphasis on UV irradiation.

  9. Endoscope disinfection and its pitfalls - requirement for retrograde surveillance cultures

    NARCIS (Netherlands)

    Buss, A. J.; Been, M. H.; Borgers, R. P.; Stokroos, I.; Melchers, W. J. G.; Peters, F. T. M.; Limburg, A. J.; Degener, J. E.

    Background and study aims: Several endoscopy-related outbreaks of infection have been reported in recent years. For early recognition of inadequate disinfection of endoscopes we designed a microbiological surveillance system to evaluate the efficacy of the cleaning and disinfection procedure, and to

  10. Transformation of pharmaceuticals during oxidation/disinfection processes in drinking water treatment

    International Nuclear Information System (INIS)

    Postigo, Cristina; Richardson, Susan D.

    2014-01-01

    Graphical abstract: - Highlights: • Review of transformation pathways of pharmaceuticals during disinfection processes. • DBPs are formed with chlorine, chloramine, ozone, chlorine dioxide, UV, or UV/H 2 O 2 . • Chlorine reacts with amine and reduced sulfur groups and activated aromatic systems. • Chlorine dioxide and ozone react with electron-rich functional groups. • Potential health effects are noted for some pharmacuetical DBPs when available. - Abstract: Pharmaceuticals are emerging contaminants of concern and are widespread in the environment. While the levels of these substances in finished drinking waters are generally considered too low for human health concern, there are now concerns about their disinfection by-products (DBPs) that can form during drinking water treatment, which in some cases have been proven to be more toxic than the parent compounds. The present manuscript reviews the transformation products of pharmaceuticals generated in water during different disinfection processes, i.e. chlorination, ozonation, chloramination, chlorine dioxide, UV, and UV/hydrogen peroxide, and the main reaction pathways taking place. Most of the findings considered for this review come from controlled laboratory studies involving reactions of pharmaceuticals with these oxidants used in drinking water treatment

  11. Transformation of pharmaceuticals during oxidation/disinfection processes in drinking water treatment

    Energy Technology Data Exchange (ETDEWEB)

    Postigo, Cristina [Institute for Environmental Assessment and Water Research (IDAEA)—Spanish National Research Council (CID-CSIC), Barcelona (Spain); Richardson, Susan D., E-mail: richardson.susan@sc.edu [Department of Chemistry and Biochemistry, University of South Carolina, Columbia, SC (United States)

    2014-08-30

    Graphical abstract: - Highlights: • Review of transformation pathways of pharmaceuticals during disinfection processes. • DBPs are formed with chlorine, chloramine, ozone, chlorine dioxide, UV, or UV/H{sub 2}O{sub 2}. • Chlorine reacts with amine and reduced sulfur groups and activated aromatic systems. • Chlorine dioxide and ozone react with electron-rich functional groups. • Potential health effects are noted for some pharmacuetical DBPs when available. - Abstract: Pharmaceuticals are emerging contaminants of concern and are widespread in the environment. While the levels of these substances in finished drinking waters are generally considered too low for human health concern, there are now concerns about their disinfection by-products (DBPs) that can form during drinking water treatment, which in some cases have been proven to be more toxic than the parent compounds. The present manuscript reviews the transformation products of pharmaceuticals generated in water during different disinfection processes, i.e. chlorination, ozonation, chloramination, chlorine dioxide, UV, and UV/hydrogen peroxide, and the main reaction pathways taking place. Most of the findings considered for this review come from controlled laboratory studies involving reactions of pharmaceuticals with these oxidants used in drinking water treatment.

  12. Experiments on sheet metal shearing

    OpenAIRE

    Gustafsson, Emil

    2013-01-01

    Within the sheet metal industry, different shear cutting technologies are commonly used in several processing steps, e.g. in cut to length lines, slitting lines, end cropping etc. Shearing has speed and cost advantages over competing cutting methods like laser and plasma cutting, but involves large forces on the equipment and large strains in the sheet material.Numerical models to predict forces and sheared edge geometry for different sheet metal grades and different shear parameter set-ups a...

  13. Disinfection of contaminated water by using solar irradiation.

    Science.gov (United States)

    Caslake, Laurie F; Connolly, Daniel J; Menon, Vilas; Duncanson, Catriona M; Rojas, Ricardo; Tavakoli, Javad

    2004-02-01

    Contaminated water causes an estimated 6 to 60 billion cases of gastrointestinal illness annually. The majority of these cases occur in rural areas of developing nations where the water supply remains polluted and adequate sanitation is unavailable. A portable, low-cost, and low-maintenance solar unit to disinfect unpotable water has been designed and tested. The solar disinfection unit was tested with both river water and partially processed water from two wastewater treatment plants. In less than 30 min in midday sunlight, the unit eradicated more than 4 log10 U (99.99%) of bacteria contained in highly contaminated water samples. The solar disinfection unit has been field tested by Centro Panamericano de Ingenieria Sanitaria y Ciencias del Ambiente in Lima, Peru. At moderate light intensity, the solar disinfection unit was capable of reducing the bacterial load in a controlled contaminated water sample by 4 log10 U and disinfected approximately 1 liter of water in 30 min.

  14. Impact of disinfection on drinking water biofilm bacterial community.

    Science.gov (United States)

    Mi, Zilong; Dai, Yu; Xie, Shuguang; Chen, Chao; Zhang, Xiaojian

    2015-11-01

    Disinfectants are commonly applied to control the growth of microorganisms in drinking water distribution systems. However, the effect of disinfection on drinking water microbial community remains poorly understood. The present study investigated the impacts of different disinfectants (chlorine and chloramine) and dosages on biofilm bacterial community in bench-scale pipe section reactors. Illumina MiSeq sequencing illustrated that disinfection strategy could affect both bacterial diversity and community structure of drinking water biofilm. Proteobacteria tended to predominate in chloraminated drinking water biofilms, while Firmicutes in chlorinated and unchlorinated biofilms. The major proteobacterial groups were influenced by both disinfectant type and dosage. In addition, chloramination had a more profound impact on bacterial community than chlorination. Copyright © 2015. Published by Elsevier B.V.

  15. Disinfection of drinking water by ultraviolet light

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    It is no longer mandatory that a given residue of chlorine is present in drinking water and this has led to interest in the use of ultraviolet radiation for disinfection of water in large public waterworks. After a brief discussion of the effect of ultraviolet radiation related to wavelength, the most usual type of irradiation equipment is briefly described. Practioal considerations regarding the installation, such as attenuation of the radiation due to water quality and deposits are presented. The requirements as to dose and residence time are also discussed and finally it is pointed out that hydraulic imperfections can reduce the effectiveness drastically. (JIW)Ψ

  16. Acanthamoeba polyphaga resuscitates viable non-culturable Legionella pneumophila after disinfection.

    Science.gov (United States)

    García, María Teresa; Jones, Snake; Pelaz, Carmen; Millar, Richard D; Abu Kwaik, Yousef

    2007-05-01

    Amoebae are the natural hosts for Legionella pneumophila and play essential roles in bacterial ecology and infectivity to humans. When L. pneumophila colonizes an aquatic installation, it can persist for years despite repeated treatments with disinfectants. We hypothesized that freshwater amoebae play an important role in bacterial resistance to disinfectants, and in subsequent resuscitation of viable non-culturable (VNC) L. pneumophila that results in re-emergence of the disease-causing strain in the disinfected water source. Our work showed that in the absence of Acanthamoeba polyphaga, seven L. pneumophila strains became non-culturable after treatment by 256 p.p.m. of sodium hypochlorite (NaOCl). In contrast, intracellular L. pneumophila within A. polyphaga was resistant to 1024 p.p.m. of NaOCl. In addition, L. pneumophila-infected A. polyphaga exhibited increased resistance to NaOCl. When chlorine-sterilized water samples were co-cultured with A. polyphaga, the non-culturable L. pneumophila were resuscitated and proliferated robustly within A. polyphaga. Upon treatment by NaOCl, uninfected amoebae differentiated into cysts within 48 h. In contrast, L. pneumophila-infected A. polyphaga failed to differentiate into cysts, and L. pneumophila was never detected in cysts of A. polyphaga. We conclude that amoebic trophozoites protect intracellular L. pneumophila from eradication by NaOCl, and play an essential role in resuscitation of VNC L. pneumophila in NaOCl-disinfected water sources. Intracellular L. pneumophila within trophozoites of A. polyphaga block encystation of the amoebae, and the resistance of both organisms to NaOCl is enhanced. To ensure long-term eradication and complete loss of the VNC state of L. pneumophila, we recommend that Legionella-protozoa co-culture should be an important tool to ensure complete loss of the VNC state of L. pneumophila.

  17. The role of surface disinfection in infection prevention

    Science.gov (United States)

    Gebel, Jürgen; Exner, Martin; French, Gary; Chartier, Yves; Christiansen, Bärbel; Gemein, Stefanie; Goroncy-Bermes, Peter; Hartemann, Philippe; Heudorf, Ursel; Kramer, Axel; Maillard, Jean-Yves; Oltmanns, Peter; Rotter, Manfred; Sonntag, Hans-Günther

    2013-01-01

    Background: The Rudolf Schuelke Foundation addresses topics related to hygiene, infection prevention and public health. In this context a panel of scientists from various European countries discussed “The Role of Surface Disinfection in Infection Prevention”. The most important findings and conclusions of this meeting are summarised in the present consensus paper. Aim: Although the relevance of surface disinfection is increasingly being accepted, there are still a number of issues which remain controversial. In particular, the following topics were addressed: Transferral of microbes from surface to patients as a cause of infection, requirements for surface disinfectants, biocidal resistance and toxicity, future challenges. Methods and findings: After discussion and review of current scientific literature the authors agreed that contaminated surfaces contribute to the transmission of pathogens and may thus pose an infection hazard. Targeted surface disinfection based on a risk profile is seen as an indispensable constituent in a multibarrier approach of universal infection control precautions. Resistance and cross-resistance depend on the disinfectant agent as well as on the microbial species. Prudent implementation of surface disinfection regimens tested to be effective can prevent or minimize adverse effects. Conclusions: Disinfection must be viewed as a holistic process. There is a need for defining standard principles for cleaning and disinfection, for ensuring compliance with these principles by measures such as written standard operating procedures, adequate training and suitable audit systems. Also, test procedures must be set up in order to demonstrate the efficacy of disinfectants including new application methods such as pre-soaked wipes for surface disinfection. PMID:23967396

  18. A pilot solar water disinfecting system: performance analysis and testing

    Energy Technology Data Exchange (ETDEWEB)

    Saitoh, T.S.; El-Ghetany, H.H. [Tohoku University, Sendai (Japan). Dept. of Aeronautics and Space Engineering

    2002-07-01

    In most countries, contaminated water is the major cause of most water-borne diseases. Disinfection of water may be accomplished by a number of different physical-chemical treatments including direct application of thermal energy, chemical and filtration techniques. Solar energy also can be used effectively in this field because inactivation of microorganisms is done either by heating water to a disinfecting temperature or by exposing it to ultraviolet solar radiation. A pilot solar system for disinfecting contaminated water is designed, constructed and tested. Investigations are carried out to evaluate the performance of a wooden hot box solar facility as a solar disinfectant. Experimental data show that solar energy is viable for the disinfection process. A solar radiation model is presented and compared with the experimental data. A mathematical model of the solar disinfectant is also presented. The governing equations are solved numerically via the fourth-order Runge-Kutta method. The effects of environmental conditions (ambient temperature, wind speed, solar radiation, etc.) on the performance of the solar disinfectant are examined. Results showed that the system is affected by ambient temperature, wind speed, ultraviolet solar radiation intensity, the turbidity of the water, the quantity of water exposed, the contact area between the transparent water container in the solar disinfectant and the absorber plate as well as the geometrical parameters of the system. It is pointed out that for partially cloudy conditions with a low ambient temperature and high wind speeds, the thermal efficiency of the solar disinfectant is at a minimum. The use of solar energy for the disinfection process will increase the productivity of the system while completely eliminating the coliform group bacteria at the same time. (author)

  19. The role of surface disinfection in infection prevention

    Directory of Open Access Journals (Sweden)

    Gebel, Jürgen

    2013-04-01

    Full Text Available [english] Background: The Rudolf Schuelke Foundation addresses topics related to hygiene, infection prevention and public health. In this context a panel of scientists from various European countries discussed “The Role of Surface Disinfection in Infection Prevention”. The most important findings and conclusions of this meeting are summarised in the present consensus paper.Aim: Although the relevance of surface disinfection is increasingly being accepted, there are still a number of issues which remain controversial. In particular, the following topics were addressed: Transferral of microbes from surface to patients as a cause of infection, requirements for surface disinfectants, biocidal resistance and toxicity, future challenges.Methods and findings: After discussion and review of current scientific literature the authors agreed that contaminated surfaces contribute to the transmission of pathogens and may thus pose an infection hazard. Targeted surface disinfection based on a risk profile is seen as an indispensable constituent in a multibarrier approach of universal infection control precautions. Resistance and cross-resistance depend on the disinfectant agent as well as on the microbial species. Prudent implementation of surface disinfection regimens tested to be effective can prevent or minimize adverse effects.Conclusions: Disinfection must be viewed as a holistic process. There is a need for defining standard principles for cleaning and disinfection, for ensuring compliance with these principles by measures such as written standard operating procedures, adequate training and suitable audit systems. Also, test procedures must be set up in order to demonstrate the efficacy of disinfectants including new application methods such as pre-soaked wipes for surface disinfection.

  20. Costs of Emergency Care

    Science.gov (United States)

    ... All RSS Feeds ACEP In the News Multimedia Image Gallery ACEP Video ACEP Radio ACEP Ads Resources Statistics & Reports Health Policy Campaigns Published Letters Journalism Awards Fact Sheets Social Media Contact Us Site Body Main Content Annals of Emergency Medicine | EMAF Website | ...

  1. 9 CFR 52.7 - Disinfection of premises, conveyances, and materials.

    Science.gov (United States)

    2010-01-01

    ... cleaning and disinfection, unless an official pseudorabies epidemiologist determines that a shorter or... and disinfection, except for cleaning and disinfection of the conveyances used to transport the swine... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Disinfection of premises, conveyances...

  2. 9 CFR 55.4 - Disinfection of premises, conveyances, and materials.

    Science.gov (United States)

    2010-01-01

    ... paid will be responsible for expenses incurred in connection with the cleaning and disinfection, except that APHIS or a State will pay for cleaning and disinfection of the conveyances used to transport the... disinfecting premises when the procedures needed to conduct effective cleaning and disinfection are unusually...

  3. Fine Sprays for Disinfection within Healthcare

    Directory of Open Access Journals (Sweden)

    G Nasr

    2016-09-01

    Full Text Available Problems exist worldwide with Hospital Acquired Infections (HAI's. The Spray Research Group (SRG have been working with relevant industries in developing a product which can provide a delivery system for treatment chemicals for surfaces, including the design and testing of a novel Spill-Return Atomiser (SRA for this purpose. A comprehensive description of this atomiser has already been given. This paper reports on a new application of this atomiser and discusses the problem of spray coating for disinfection that has been considered very little in previous work. The related spray coating performance tests in developing the product are thus provided. The experimental work includes determining the required spray duration and the coverage area produced by different sprays, including the analysis of the effects of atomiser positions, configurations, and the required number of atomisers. Comparison is made with the efficacy of an ultrasonic gas atomiser that is currently used for this purpose. The investigation has found that the utilisation of fine sprays (10μm>D32>25μm at high liquid pressure (<12MPa and low flow rates (<0.3 l/min is suitable for surface disinfection in healthcare applications (i.e. MRSA, VRSA etc.

  4. Cleansing and Disinfection in the Food Industry

    Directory of Open Access Journals (Sweden)

    Ruhtan Baskaya

    2009-02-01

    Full Text Available In the applications of industrial hygiene, it is of utmost importance to define the potential risk factors in the business enterprise in question, to pay sufficient consideration to those factors, and to spend every effort for their checking and elimination. In that sense, cleansing and disinfection applications have a basic importance. Food hygiene covers all the efforts spent in order to ensure the proper conditions for the production of healthy food at every stage of the production process, extending from the farm to the table. Cleansing is the removal of the dirt or food leftovers found on the tools and equipment contacting food, and preventing their conversion into a convenient millieu for the reproduction of microorganisms. Cleansing is the process of removing not only the visible dirts and leftovers, but also a large part of the visible microorganisms. Disinfection is applied after cleansing; it is the process of disintegration of microorganisms which can cause contamination, or reduction of those microorganisms to minimum levels so that they can not create any harmful effects. [TAF Prev Med Bull 2009; 8(1.000: 93-106

  5. Wastewater disinfection with peracetic acid and UV

    International Nuclear Information System (INIS)

    Caretti, C.; Lubello, C.

    2001-01-01

    Was investigated the synergy between UV and peracetic acid (PAA) through a five months on-site experimental study in a pilot plant fed by the secondary effluent of the central wastewater treatment plant of Pistoia, Italy. This experiment is a part of a larger research project on advanced treatment for municipal wastewater reuse in agriculture. Because of Italy's strict limits on unrestricted wastewater reuse in agriculture (2 CFU total coliform/100 ml), a very high degree of disinfection is necessary. In the investigated experimental conditions, it has been impossible to meet such values through an exclusive use of UV irradiation (the UV unit reaches at most 4 Log inactivation). Low levels of PAA greatly enhance the decline of indicator levels, but higher unsustainable doses are required to hit the Italian limit. Through a poor amount of information on the subject was available in literature, it was tried to find out how the disinfection efficiency could improve by simultaneously using UV and PAA. It was found out that a combined treatment is satisfactory and that it is more advantage of the hydroxyl radicals formation due to the PAA photo lysis. The application of 2 ppm of PAA with an UV dose of 192 mWscm - 2 is enough to meet the Italian limit [it

  6. Quality control of disinfection in ultrasonic baths

    Energy Technology Data Exchange (ETDEWEB)

    Schoene, H. [Technical University Dresden (Germany). Faculty of Mechanical Engineering; Jatzwauk, L. [University Hospital of the Technical University Dresden (Germany). Abt. Krankenhaushygiene

    2002-07-01

    Numerous investigations under laboratory conditions confirmed the microbicidal efficacy of ultrasonication. Morphological destruction was shown on bacteria and fungi as well as on different virus species. Ultrasonic treatment seems to increase the effect of different antibiotics and disinfectants. Reasons for this synergism are largely unknown and uninvestigated, but the active principle seems to bee the dispersing effect of ultrasonication in combination with the destruction of cell wall or cell membrane. Unfortunately no validation of test conditions exists for most of these investigations, regarding intensity and frequency of ultrasonic waves, temperature of liquid medium and measurement of cavitation which is an essential part of physical and chemical effects in ultrasonic baths. In contrast to most laboratory experiments sound density of ultrasound for treatment of medical instruments is below 1 W/cm{sup 2} because instruments will be destroyed under stronger ultrasonic conditions. The frequency is below 50 KHz. This paper describes bactericidal and fungicidal effects of low- intensity-ultrasonication and its synergistical support to chemical disinfection. (orig.)

  7. Soft Costs Fact Sheet

    Energy Technology Data Exchange (ETDEWEB)

    None

    2016-05-01

    This fact sheet is an overview of the systems integration subprogram at the U.S. Department of Energy SunShot Initiative. Soft costs can vary significantly as a result of a fragmented energy marketplace. In the U.S., there are 18,000 jurisdictions and 3,000 utilities with different rules and regulations for how to go solar. The same solar equipment may vary widely in its final installation price due to process and market variations across jurisdictions, creating barriers to rapid industry growth. SunShot supports the development of innovative solutions that enable communities to build their local economies and establish clean energy initiatives that meet their needs, while at the same time creating sustainable solar market conditions.

  8. Photovoltaics Fact Sheet

    Energy Technology Data Exchange (ETDEWEB)

    None

    2016-02-01

    This fact sheet is an overview of the Photovoltaics (PV) subprogram at the U.S. Department of Energy SunShot Initiative. The U.S. Department of Energy (DOE)’s Solar Energy Technologies Office works with industry, academia, national laboratories, and other government agencies to advance solar PV, which is the direct conversion of sunlight into electricity by a semiconductor, in support of the goals of the SunShot Initiative. SunShot supports research and development to aggressively advance PV technology by improving efficiency and reliability and lowering manufacturing costs. SunShot’s PV portfolio spans work from early-stage solar cell research through technology commercialization, including work on materials, processes, and device structure and characterization techniques.

  9. Systems Integration Fact Sheet

    Energy Technology Data Exchange (ETDEWEB)

    None

    2016-06-01

    This fact sheet is an overview of the Systems Integration subprogram at the U.S. Department of Energy SunShot Initiative. The Systems Integration subprogram enables the widespread deployment of safe, reliable, and cost-effective solar energy technologies by addressing the associated technical and non-technical challenges. These include timely and cost-effective interconnection procedures, optimal system planning, accurate prediction of solar resources, monitoring and control of solar power, maintaining grid reliability and stability, and many more. To address the challenges associated with interconnecting and integrating hundreds of gigawatts of solar power onto the electricity grid, the Systems Integration program funds research, development, and demonstration projects in four broad, interrelated focus areas: grid performance and reliability, dispatchability, power electronics, and communications.

  10. Hyperspectral light sheet microscopy

    Science.gov (United States)

    Jahr, Wiebke; Schmid, Benjamin; Schmied, Christopher; Fahrbach, Florian O.; Huisken, Jan

    2015-09-01

    To study the development and interactions of cells and tissues, multiple fluorescent markers need to be imaged efficiently in a single living organism. Instead of acquiring individual colours sequentially with filters, we created a platform based on line-scanning light sheet microscopy to record the entire spectrum for each pixel in a three-dimensional volume. We evaluated data sets with varying spectral sampling and determined the optimal channel width to be around 5 nm. With the help of these data sets, we show that our setup outperforms filter-based approaches with regard to image quality and discrimination of fluorophores. By spectral unmixing we resolved overlapping fluorophores with up to nanometre resolution and removed autofluorescence in zebrafish and fruit fly embryos.

  11. Reconstructing the last Irish Ice Sheet 2: a geomorphologically-driven model of ice sheet growth, retreat and dynamics

    Science.gov (United States)

    Greenwood, Sarah L.; Clark, Chris D.

    2009-12-01

    The ice sheet that once covered Ireland has a long history of investigation. Much prior work focussed on localised evidence-based reconstructions and ice-marginal dynamics and chronologies, with less attention paid to an ice sheet wide view of the first order properties of the ice sheet: centres of mass, ice divide structure, ice flow geometry and behaviour and changes thereof. In this paper we focus on the latter aspect and use our new, countrywide glacial geomorphological mapping of the Irish landscape (>39 000 landforms), and our analysis of the palaeo-glaciological significance of observed landform assemblages (article Part 1), to build an ice sheet reconstruction yielding these fundamental ice sheet properties. We present a seven stage model of ice sheet evolution, from initiation to demise, in the form of palaeo-geographic maps. An early incursion of ice from Scotland likely coalesced with local ice caps and spread in a south-westerly direction 200 km across Ireland. A semi-independent Irish Ice Sheet was then established during ice sheet growth, with a branching ice divide structure whose main axis migrated up to 140 km from the west coast towards the east. Ice stream systems converging on Donegal Bay in the west and funnelling through the North Channel and Irish Sea Basin in the east emerge as major flow components of the maximum stages of glaciation. Ice cover is reconstructed as extending to the continental shelf break. The Irish Ice Sheet became autonomous (i.e. separate from the British Ice Sheet) during deglaciation and fragmented into multiple ice masses, each decaying towards the west. Final sites of demise were likely over the mountains of Donegal, Leitrim and Connemara. Patterns of growth and decay of the ice sheet are shown to be radically different: asynchronous and asymmetric in both spatial and temporal domains. We implicate collapse of the ice stream system in the North Channel - Irish Sea Basin in driving such asymmetry, since rapid

  12. Efficiency of cleaning and disinfection of surfaces: correlation between assessment methods

    OpenAIRE

    Frota, Oleci Pereira; Ferreira, Adriano Menis; Guerra, Odanir Garcia; Rigotti, Marcelo Alessandro; Andrade, Denise de; Borges, Najla Moreira Amaral; Almeida, Margarete Teresa Gottardo de

    2017-01-01

    ABSTRACT Objective: to assess the correlation among the ATP-bioluminescence assay, visual inspection and microbiological culture in monitoring the efficiency of cleaning and disinfection (C&D) of high-touch clinical surfaces (HTCS) in a walk-in emergency care unit. Method: a prospective and comparative study was carried out from March to June 2015, in which five HTCS were sampled before and after C&D by means of the three methods. The HTCS were considered dirty when dust, waste, humidity an...

  13. Effects of disinfecting alginate impressions on the scratch hardness of stone models.

    Science.gov (United States)

    Hiraguchi, Hisako; Nakagawa, Hisami; Wakashima, Mitsuru; Miyanaga, Kohichi; Saigo, Masataka; Nishiyama, Minoru

    2006-03-01

    This study investigated the effects of disinfecting alginate impressions on the scratch depth of resultant stone models. Eleven brands of alginate impression material and two disinfectants, 1% sodium hypochlorite and 2% glutaraldehyde, were used. Impressions were immersed in disinfectant solutions or stored in sealed bags after spraying with disinfectants, and then poured with a type V dental stone. The scratch depth of the stone model obtained from disinfected impression was measured. The storage of alginate impressions after spraying with disinfectants did not increase the scratch depth of resultant stone models. However, the effect of immersion in disinfectants on scratch depth varied with the brand of the alginate impression material.

  14. Settlement during vibratory sheet piling

    NARCIS (Netherlands)

    Meijers, P.

    2007-01-01

    During vibratory sheet piling quite often the soil near the sheet pile wall will settle. In many cases this is not a problem. For situations with houses, pipelines, roads or railroads at relative short distance these settlements may not be acceptable. The purpose of the research described in this

  15. Plasma dynamics in current sheets

    International Nuclear Information System (INIS)

    Bogdanov, S.Yu.; Drejden, G.V.; Kirij, N.P.; AN SSSR, Leningrad

    1992-01-01

    Plasma dynamics in successive stages of current sheet evolution is investigated on the base of analysis of time-spatial variations of electron density and electrodynamic force fields. Current sheet formation is realized in a two-dimensional magnetic field with zero line under the action of relatively small initial disturbances (linear regimes). It is established that in the limits of the formed sheet is concentrated dense (N e ∼= 10 16 cm -3 ) (T i ≥ 100 eV, bar-Z i ≥ 2) hot pressure of which is balanced by the magnetic action of electrodynamic forces is carried out both plasma compression in the sheet limits and the acceleration along the sheet surface from a middle to narrow side edges

  16. Analysis of the Strength on the Rotor Punching Sheet of Nuclear Reactor Cooling Medium Driving Motor

    Directory of Open Access Journals (Sweden)

    GE Bao-jun

    2017-02-01

    Full Text Available A strong stress is withstood by the rotor punching sheet during the running of nuclear reactor cooling medium driving motor. In order to study the strength on the rotor punching sheet and the influential factor of its stress,the rotor of driving motor was the research object, the three-dimensional rotor model of driving motor is established by the finite element method to obtain the Mires equivalent stress nephogram and check the rotor’s strength with setting parameters and constraints. According to different rotor speeds,the different average temperatures of rotor punching sheet and shaft and the different static magnitude of interference between rotor punching sheet and shaft,the research about how the contact pressure of matching surface between rotor punching sheet and shaft and the Mires equivalent stress are impacted is carried on. The results show that the maximum Miser equivalent stress value of rotor punching sheet emerges on the axial vents,the stress value is beyond the tensile limit of the materialand. The greater the static magnitude of interference and the smaller temperature difference of rotor punching sheet and shaft lead to the greater interface compressive stress of rotor punching sheet and shaft and the greater maximum Mires equivalent stress value of rotor punching sheet. The higher the rotor speed lead to the smaller interface compressive stress of rotor punching sheet and shaft and the greater equivalent stress value of rotor punching sheet.

  17. Inactivation model for disinfection of biofilms in drinking water

    International Nuclear Information System (INIS)

    Karlicki, A.; O'Leary, K.C.; Gagnon, G.A.

    2002-01-01

    The purpose of the project was to investigate experimentally the effects of free chlorine, monochloramine and chlorine dioxide on the removal of biofilm growth in water as it applies to drinking water in distribution systems. In particular, biofilm kill for a particular dosage of disinfectant was measured as a function of time for each disinfectant over a range of disinfectant concentrations. These results were used to formulate concentration-time (Ct) inactivation values for each disinfectant to compare the efficacy of the three disinfectants for biofilm control. The biofilm reactor system consisted of a 125 mL columns, each containing tightly packed 3 mm glass beads on which heterotrophic bacterial biofilm is established. Following an initial biofilm inoculation period, the glass beads were removed from the columns and placed into glass jars for disinfection with free chlorine, monochloramine and chlorine dioxide. Cell counts were determined on a time series basis with the goal of achieving a Ct inactivation model that is similar to models presently used for inactivation of suspended cells. Ultimately this research could be used to develop a rationale method for setting regulatory values for secondary disinfection in drinking water distribution systems, which presently in only a few states and provinces. (author)

  18. ASSESSMENT OF ACTION OF DISINFECTANTS AGAINST LISTERIA MONOCYTOGENES BIOFILMS

    Directory of Open Access Journals (Sweden)

    T. K. CABEÇA

    2008-12-01

    Full Text Available

    The purpose of this study was to assess the action of various disinfectants used in food industry against biofilm cells of Listeria monocytogenes formed on stainless steel surfaces during 24, 72 and 120 hours. Numbers of viable biofilm cells decreased after treatment with all the tested disinfectants (iodine, biguanide, quaternary ammonium compounds, peracetic acid and sodium hypochlorite. Sodium hypochlorite was the most effective disinfectant against the biofilm cells, while biguanide and iodine were the least. Scanning electron microscopy observations demonstrated attached cells on stainless steel surfaces after treatment with all the disinfectants. These observations showed that microorganisms were not completely removed from stainless steel surfaces after treatment with the disinfectants, however, the attachment did not means the viability of remaining cells. The biofilm age in hours (24, 72 and 120 had no apparent influence on resistance of microbiological cells to the disinfectants under study. In conclusion biofilm cells of L. monocytogenes can withstand disinfectants action.

  19. Wettability changes in polyether impression materials subjected to immersion disinfection.

    Science.gov (United States)

    Shetty, Shweta; Kamat, Giridhar; Shetty, Rajesh

    2013-07-01

    Disinfection of impression materials prevents cross-contamination; however, the disinfectants may alter the wettability property. The purpose of this investigation was to evaluate the wettability changes of polyether impression material after immersing in four different chemical disinfectant solutions for a period of 10 min and 30 min, respectively. A total of 45 samples of polyether dental impression material (Impregum soft, 3MESPE, St. Paul, MN, USA) were randomly divided into nine groups with five specimens each. Each specimen was disc shaped, flat of 32 mm diameter and 3 mm thickness. The samples were immersed in four disinfectant solutions: 2% Glutaraldehyde, 5% sodium hypochlorite, 0.05% iodophor, and 5.25% phenol for 10 min and 30 min, respectively. The control was without disinfection. Wettability of the samples was assessed by measuring the contact angle by using the Telescopic Goniometer. Data were subjected to analysis of variance (Fisher's test) and Tukey's post hoc test for multiple comparisons at 5% level of significance. The contact angle of 20.21° ± 0.22° were recorded in the control samples. After 10 min, the samples that were immersed in 5% sodium hypochlorite and 5.25% phenol showed significant statistical increase in the contact angle as compared to the control (P polyether material. Within the limitations of the study, 2% glutaraldehyde proved safe for 10 min of immersion disinfection while 0.05% iodophor holds promise as an effective disinfectant without affecting the wettability of the material.

  20. Efficacy of a variety of disinfectants against Listeria spp.

    Science.gov (United States)

    Best, M; Kennedy, M E; Coates, F

    1990-02-01

    The efficacy of 14 disinfectants against Listeria innocua and two strains of Listeria monocytogenes in the presence of organic matter was studied. Quantitative efficacy tests were used. Many of the disinfectants tested were not as effective on Listeria spp. when the test organisms were dried onto the surface of steel disks (carrier tests) as they were when the organisms were placed in suspension (suspension test). The presence of whole serum and milk (2% fat) further reduced the disinfectant capacities of most of the formulations studied. Only three disinfectants (povidone-iodine, chlorhexidine gluconate, and glutaraldehyde) were effective in the carrier test in the presence of serum; however, all three were ineffective when challenged with milk (2% fat). Only one solution, sodium dichloroisocyanurate, was effective in the presence of milk. All but four formulations (chloramine-T, phosphoric acid, an iodophor, and formaldehyde) were effective in the suspension tests, regardless of the organic load. L. monocytogenes was observed to be slightly more resistant to disinfection than L. innocua was. There was no difference in disinfectant susceptibility between the two strains of L. monocytogenes. These findings emphasize the need for caution in selecting an appropriate disinfectant for use on contaminated surfaces, particularly in the presence of organic material.

  1. Fact Sheet: What Parents Need to Know About Zika Virus

    Science.gov (United States)

    ... Management Post-Disaster Child Care Resources ACF Capabilities Policies Resources You are here ACF Home › Office of Human Services Emergency Preparedness and Response › Resource Library › Fact Sheet: What Parents Need to Know About ...

  2. Graphene oxide–CdS composite with high photocatalytic degradation and disinfection activities under visible light irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Peng; Liu, Jincheng [School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Sun, Darren Delai, E-mail: DDSUN@ntu.edu.sg [School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Ng, Wunjern [School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Nanyang Environment and Water Research Institute, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore)

    2013-04-15

    Highlights: ► GO–CdS composites were prepared through a novel two-phase mixing method. ► Uniform deposition of CdS nanoparticles on GO sheets. ► Reduced charge recombination rate. ► Enhanced photo-stability. ► High photodegradation and disinfection efficiency. -- Abstract: Graphene oxide (GO)–CdS composites were synthesized via a novel two-phase mixing method successfully. CdS nanoparticles were uniformly self-assembled on GO sheets at water/toluene interface. The photocatalytic degradation (photodegradation) and disinfection activities of GO–CdS composites were investigated thoroughly. The results show that GO–CdS composites exhibit higher efficiency in photodegradation of various water pollutants than pure CdS nanoparticles under visible light irradiation. In addition, the interactions between GO sheets and CdS nanoparticles inhibit the photo-corrosion of CdS and leaching of Cd{sup 2+}. Only 3.5 wt% Cd{sup 2+} of GO–CdS was leached out after photodegradation, while 38.6 wt% Cd{sup 2+} of CdS was lost into aqueous solution. Furthermore, the disinfection activity of GO–CdS composites was investigated for the first time. Nearly 100% of both Gram-negative Escherichia coli (E. coli) and Gram-positive Bacillus subtilis (B. subtilis) were killed within 25 min under visible light irradiation. The excellent performances of GO–CdS composites can be attributed to that (1) effective charge transfer from CdS to GO reduces the recombination rate of photo-generated electron–hole pairs; (2) uniform deposition of CdS on GO sheets eliminates aggregation of CdS nanoparticles; and (3) the strong interactions between GO and CdS enhancing the durability of GO–CdS composites. Finally, the mechanism behind these excellent performances was verified by transient photocurrent measurement and further confirmed by ESR technique as well as employing a radical scavenging species – dimethyl sulfoxide (DMSO)

  3. Graphene oxide–CdS composite with high photocatalytic degradation and disinfection activities under visible light irradiation

    International Nuclear Information System (INIS)

    Gao, Peng; Liu, Jincheng; Sun, Darren Delai; Ng, Wunjern

    2013-01-01

    Highlights: ► GO–CdS composites were prepared through a novel two-phase mixing method. ► Uniform deposition of CdS nanoparticles on GO sheets. ► Reduced charge recombination rate. ► Enhanced photo-stability. ► High photodegradation and disinfection efficiency. -- Abstract: Graphene oxide (GO)–CdS composites were synthesized via a novel two-phase mixing method successfully. CdS nanoparticles were uniformly self-assembled on GO sheets at water/toluene interface. The photocatalytic degradation (photodegradation) and disinfection activities of GO–CdS composites were investigated thoroughly. The results show that GO–CdS composites exhibit higher efficiency in photodegradation of various water pollutants than pure CdS nanoparticles under visible light irradiation. In addition, the interactions between GO sheets and CdS nanoparticles inhibit the photo-corrosion of CdS and leaching of Cd 2+ . Only 3.5 wt% Cd 2+ of GO–CdS was leached out after photodegradation, while 38.6 wt% Cd 2+ of CdS was lost into aqueous solution. Furthermore, the disinfection activity of GO–CdS composites was investigated for the first time. Nearly 100% of both Gram-negative Escherichia coli (E. coli) and Gram-positive Bacillus subtilis (B. subtilis) were killed within 25 min under visible light irradiation. The excellent performances of GO–CdS composites can be attributed to that (1) effective charge transfer from CdS to GO reduces the recombination rate of photo-generated electron–hole pairs; (2) uniform deposition of CdS on GO sheets eliminates aggregation of CdS nanoparticles; and (3) the strong interactions between GO and CdS enhancing the durability of GO–CdS composites. Finally, the mechanism behind these excellent performances was verified by transient photocurrent measurement and further confirmed by ESR technique as well as employing a radical scavenging species – dimethyl sulfoxide (DMSO)

  4. Vitamin and Mineral Supplement Fact Sheets

    Science.gov (United States)

    ... website Submit Search NIH Office of Dietary Supplements Vitamin and Mineral Supplement Fact Sheets Search the list ... Supplements: Background Information Botanical Dietary Supplements: Background Information Vitamin and Mineral Fact Sheets Botanical Supplement Fact Sheets ...

  5. Drinking Water Supply without Use of a Disinfectant

    Science.gov (United States)

    Rajnochova, Marketa; Tuhovcak, Ladislav; Rucka, Jan

    2018-02-01

    The paper focuses on the issue of drinking water supply without use of any disinfectants. Before the public water supply network operator begins to consider switching to operation without use of chemical disinfection, initial assessment should be made, whether or not the water supply system in question is suitable for this type of operation. The assessment is performed by applying the decision algorithm. The initial assessment is followed by another decision algorithm which serves for managing and controlling the process of switching to drinking water supply without use of a disinfectant. The paper also summarizes previous experience and knowledge of this way operated public water supply systems in the Czech Republic.

  6. Sterilization, high-level disinfection, and environmental cleaning.

    Science.gov (United States)

    Rutala, William A; Weber, David J

    2011-03-01

    Failure to perform proper disinfection and sterilization of medical devices may lead to introduction of pathogens, resulting in infection. New techniques have been developed for achieving high-level disinfection and adequate environmental cleanliness. This article examines new technologies for sterilization and high-level disinfection of critical and semicritical items, respectively, and because semicritical items carry the greatest risk of infection, the authors discuss reprocessing semicritical items such as endoscopes and automated endoscope reprocessors, endocavitary probes, prostate biopsy probes, tonometers, laryngoscopes, and infrared coagulation devices. In addition, current issues and practices associated with environmental cleaning are reviewed. Copyright © 2011. Published by Elsevier Inc.

  7. 75 FR 45144 - Recovery Fact Sheet 9580.203, Debris Monitoring

    Science.gov (United States)

    2010-08-02

    ... DEPARTMENT OF HOMELAND SECURITY Federal Emergency Management Agency [Docket ID FEMA-2010-0045] Recovery Fact Sheet 9580.203, Debris Monitoring AGENCY: Federal Emergency Management Agency, DHS. ACTION: Notice of availability; request for comments. SUMMARY: The Federal Emergency Management Agency (FEMA) is...

  8. Selectively reflective transparent sheets

    Science.gov (United States)

    Waché, Rémi; Florescu, Marian; Sweeney, Stephen J.; Clowes, Steven K.

    2015-08-01

    We investigate the possibility to selectively reflect certain wavelengths while maintaining the optical properties on other spectral ranges. This is of particular interest for transparent materials, which for specific applications may require high reflectivity at pre-determined frequencies. Although there exist currently techniques such as coatings to produce selective reflection, this work focuses on new approaches for mass production of polyethylene sheets which incorporate either additives or surface patterning for selective reflection between 8 to 13 μ m. Typical additives used to produce a greenhouse effect in plastics include particles such as clays, silica or hydroxide materials. However, the absorption of thermal radiation is less efficient than the decrease of emissivity as it can be compared with the inclusion of Lambertian materials. Photonic band gap engineering by the periodic structuring of metamaterials is known in nature for producing the vivid bright colors in certain organisms via strong wavelength-selective reflection. Research to artificially engineer such structures has mainly focused on wavelengths in the visible and near infrared. However few studies to date have been carried out to investigate the properties of metastructures in the mid infrared range even though the patterning of microstructure is easier to achieve. We present preliminary results on the diffuse reflectivity using FDTD simulations and analyze the technical feasibility of these approaches.

  9. Enhanced photocatalytic disinfection of indoor air

    Energy Technology Data Exchange (ETDEWEB)

    Vohra, Amit; Goswami, D.Y.; Deshpande, D.A.; Block, S.S. [Solar Energy and Energy Conversion Laboratory, Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, FL 32611 (United States)

    2006-04-18

    A silver ion doped TiO{sub 2} based photocatalyst, with improved destruction of airborne microbes, has been developed. The performance of the silver ion doped photocatalyst is demonstrated using a catalyst coated filter in a recirculating air experimental facility. Bacillus cereus, Staphylococcus aureus, Escherichia coli, Aspergillus niger, and MS2 Bacteriophage have been used as indexes to demonstrate the high disinfection efficiency of the enhanced photocatalysis process. The microbial destruction performance of the enhanced photocatalyst is found to be an order of magnitude higher than that of a conventional TiO{sub 2} photocatalyst. The process of enhanced photocatalysis can thus be used effectively against high concentrations of airborne microorganisms, making it an attractive option as a defense against bio-terrorism. (author)

  10. Antimicrobial-Coated Granules for Disinfecting Water

    Science.gov (United States)

    Akse, James R.; Holtsnider, John T.; Kliestik, Helen

    2011-01-01

    Methods of preparing antimicrobialcoated granules for disinfecting flowing potable water have been developed. Like the methods reported in the immediately preceding article, these methods involve chemical preparation of substrate surfaces (in this case, the surfaces of granules) to enable attachment of antimicrobial molecules to the surfaces via covalent bonds. A variety of granular materials have been coated with a variety of antimicrobial agents that include antibiotics, bacteriocins, enzymes, bactericides, and fungicides. When employed in packed beds in flowing water, these antimicrobial-coated granules have been proven effective against gram-positive bacteria, gram-negative bacteria, fungi, and viruses. Composite beds, consisting of multiple layers containing different granular antimicrobial media, have proven particularly effective against a broad spectrum of microorganisms. These media have also proven effective in enhancing or potentiating the biocidal effects of in-line iodinated resins and of very low levels of dissolved elemental iodine.

  11. Superfund fact sheet: The remedial program. Fact sheet

    International Nuclear Information System (INIS)

    1992-09-01

    The fact sheet describes what various actions the EPA can take to clean up hazardous wastes sites. Explanations of how the criteria for environmental and public health risk assessment are determined and the role of state and local governments in site remediation are given. The fact sheet is one in a series providing reference information about Superfund issues and is intended for readers with no formal scientific training

  12. Effects of different cavity‑disinfectants and potassium titanyl ...

    African Journals Online (AJOL)

    disinfectants and potassium titanyl phosphate (KTP) laser on microtensile bond strength to primary dentin. Chlorhexidine (CHX), propolis (PRO), ozonated water (OW), gaseous ozone (OG) and KTP laser were used for this purpose. Methodology: ...

  13. Drinking water disinfection by means of ultraviolet radiation

    International Nuclear Information System (INIS)

    Gelzhaeuser, P.; Bewig, F.; Holm, K.; Kryschi, R.; Reich, G.; Steuer, W.

    1985-01-01

    The book presents all lectures held during a course at Technical Academy Esslingen, on September 10, 1985, on the subject of 'Drinking water disinfection by means of ultraviolet radiation'. The methods hitherto used for disinfection are no longer suitable because of the increasing amounts of organic pollutants found in the untreated water, and because of the necessity to make drinking water disinfection less expensive, non-polluting and thus environmentally compatible. U.V. irradiation is a method allowing technically simple and safe disinfection of the water, and also does not have any effect on the natural taste of the drinking water. The lectures presented discuss all aspects of the method, the equipment, and the performance of irradiation systems in practice. (orig./PW) [de

  14. Waterline ATS B. globigii spore water disinfection data

    Data.gov (United States)

    U.S. Environmental Protection Agency — Disinfection of B. globigii spores (a non-pathogenic surrogate for B. anthracis) in clean and dirty water using the ATS-Waterline system, which uses ultraviolet...

  15. Effect of ultrasonic pretreatment on purified water disinfection

    International Nuclear Information System (INIS)

    Simon Andreu, P.; Lardin Mifsut, C.; Vergara Romero, L.; Polo Canas, P. M.; Perez Sanchez, P.; Rancano Perez, A.

    2009-01-01

    Due to the importance of a suitable water disinfection in order to insure a pollutant effect minimization against environment, this work has been carried out to determine how can affect an ultrasonic pre-treatment upon disinfection step. It has been confirmed the ultrasonic disintegration of bacterial cells in treated water and disinfectant power of treatment by itself, which is not enough to be used as a single method in water disinfection. It has also been proved that from a technical and economical point of view the combination of UV and ultrasound improves the UV treatment performance. Finally, it has been detected that an ultrasonic pre-treatment increases chlorination effectiveness, however the high cost in this combination makes it unfeasible of industrial scale. (Author) 6 refs

  16. Effect of hydrodynamic cavitation on zooplankton: A tool for disinfection

    Digital Repository Service at National Institute of Oceanography (India)

    Sawant, S.S.; Anil, A.C.; Venkat, K.; Gaonkar, C.; Kolwalkar, J.; Khandeparker, L.; Desai, D.V.; Mahulkar, A.V.; Ranade, V.V.; Pandit, A.B.

    by individual oscillating cavity, cell wall strength and geometrical and operating parameters of cavitation device. Theoretical model for quantifying the cavitationally generated turbulent shear and extent of microbial disinfection has been developed...

  17. Assessment of apparent effectiveness of chemical egg disinfectants ...

    African Journals Online (AJOL)

    Aquaculture holds the potential to supplement catches as well as produce seed ... re-circulating incubation system at the National Aquaculture Center, Domasi, Malawi. ... Key words: Egg, disinfectants, incubation, recirculation, hatchability, egg ...

  18. development of an automated batch-process solar water disinfection

    African Journals Online (AJOL)

    user

    This work presents the development of an automated batch-process water disinfection system ... Locally sourced materials in addition to an Arduinomicro processor were used to control ..... As already mentioned in section 3.1.1, a statistical.

  19. IDENTIFICATION OF TI02/UV DISINFECTION BYPRODUCTS IN DRINKING WATER

    Science.gov (United States)

    Due to concern over the presence of trihalomethanes (THMs) and other chlorinated byproducts in chlorinated drinking water, alternative disinfection methods are being explored. One of the alternative treatment methods currently being evaluated for potential use with small systems ...

  20. Selecting a Sustainable Disinfection Technique for Wastewater Reuse Projects

    Directory of Open Access Journals (Sweden)

    Jorge Curiel-Esparza

    2014-09-01

    Full Text Available This paper presents an application of the Analytical Hierarchy Process (AHP by integrating a Delphi process for selecting the best sustainable disinfection technique for wastewater reuse projects. The proposed methodology provides project managers a tool to evaluate problems with multiple criteria and multiple alternatives which involve non-commeasurable decision criteria, with expert opinions playing a major role in the selection of these treatment technologies. Five disinfection techniques for wastewater reuse have been evaluated for each of the nine criteria weighted according to the opinions of consulted experts. Finally, the VIKOR method has been applied to determine a compromise solution, and to establish the stability of the results. Therefore, the expert system proposed to select the optimal disinfection alternative is a hybrid method combining the AHP with the Delphi method and the VIKOR technique, which is shown to be appropriate in realistic scenarios where multiple stakeholders are involved in the selection of a sustainable disinfection technique for wastewater reuse projects.

  1. Mimicking disinfection and drying of biofilms in contaminated endoscopes

    NARCIS (Netherlands)

    Kovaleva, J.; Degener, J. E.; van der Mei, H. C.

    2010-01-01

    The effects of peracetic acid-based (PAA) disinfectant with, and without, additional drying on Candida albicans, Candida parapsilosis, Pseudomonas aeruginosa and Stenotrophomonas maltophilia, isolated from contaminated flexible endoscopes, in single-and dual-species biofilms were studied. Biofilms

  2. Principles for designing proteins with cavities formed by curved β sheets

    Energy Technology Data Exchange (ETDEWEB)

    Marcos, Enrique; Basanta, Benjamin; Chidyausiku, Tamuka M.; Tang, Yuefeng; Oberdorfer, Gustav; Liu, Gaohua; Swapna, G. V. T.; Guan, Rongjin; Silva, Daniel-Adriano; Dou, Jiayi; Pereira, Jose Henrique; Xiao, Rong; Sankaran, Banumathi; Zwart, Peter H.; Montelione, Gaetano T.; Baker, David

    2017-01-12

    Active sites and ligand-binding cavities in native proteins are often formed by curved β sheets, and the ability to control β-sheet curvature would allow design of binding proteins with cavities customized to specific ligands. Toward this end, we investigated the mechanisms controlling β-sheet curvature by studying the geometry of β sheets in naturally occurring protein structures and folding simulations. The principles emerging from this analysis were used to design, de novo, a series of proteins with curved β sheets topped with α helices. Nuclear magnetic resonance and crystal structures of the designs closely match the computational models, showing that β-sheet curvature can be controlled with atomic-level accuracy. Our approach enables the design of proteins with cavities and provides a route to custom design ligand-binding and catalytic sites.

  3. Selection Criteria for Water Disinfection Techniques in Agricultural Practices

    OpenAIRE

    Haute, Sam van; Sampers, Imca; Jacxsens, Liesbeth; Uyttendaele, Mieke

    2013-01-01

    This paper comprises a selection tool for water disinfection methods for fresh produce pre- and postharvest practices. A variety of water disinfection technologies is available on the market and no single technology is the best choice for all applications. It can be difficult for end users to choose the technology that is best fit for a specific application. Therefore, the different technologies were characterized in order to identify criteria that influence the suitability of a technology fo...

  4. Methodological approaches to disinfection of human hepatitis B virus.

    OpenAIRE

    Prince, D L; Prince, H N; Thraenhart, O; Muchmore, E; Bonder, E; Pugh, J

    1993-01-01

    Three commercial disinfectants (two quaternary formulations and one phenolic) were tested against human hepatitis B virus (HHBV). The treated virus was assayed for infectivity by the chimpanzee assay and for morphological alteration by the Morphological Alteration and Disintegration Test. The same agents were tested against duck hepatitis B virus in a duck hepatocyte infectivity assay. It is apparent that human and duck hepatitis viruses were relatively susceptible to disinfection, becoming n...

  5. Composting of gamma-radiation disinfected sewage sludge

    International Nuclear Information System (INIS)

    Kawakami, W.; Hashimoto, S.; Watanabe, H.; Nishimura, K.; Watanabe, H.; Ito, H.; Takehisa, M.

    1981-01-01

    The composting of radiation disinfected sewage sludge has been studied since 1978, aiming to present a new process of sludge composting for agricultural uses. This process is composed of two steps: irradiation step to disinfect sludge, and composting step to remove odor and easily decomposable organics in sludge. In this paper, the gamma-irradiation effect on sludge cake and composting condition of irradiated sludge are discussed. (author)

  6. 2012 Swimming Season Fact Sheets

    Science.gov (United States)

    To help beachgoers make informed decisions about swimming at U.S. beaches, EPA annually publishes state-by-state data about beach closings and advisories for the previous year's swimming season. These fact sheets summarize that information by state.

  7. State Fact Sheets on COPD

    Science.gov (United States)

    ... Submit Search The CDC Chronic Obstructive Pulmonary Disease (COPD) Note: Javascript is disabled or is not supported ... message, please visit this page: About CDC.gov . COPD Homepage Data and Statistics Fact Sheets Publications Publications ...

  8. A Review of Heterogeneous Photocatalysis for Water and Surface Disinfection

    Directory of Open Access Journals (Sweden)

    John Anthony Byrne

    2015-03-01

    Full Text Available Photo-excitation of certain semiconductors can lead to the production of reactive oxygen species that can inactivate microorganisms. The mechanisms involved are reviewed, along with two important applications. The first is the use of photocatalysis to enhance the solar disinfection of water. It is estimated that 750 million people do not have accessed to an improved source for drinking and many more rely on sources that are not safe. If one can utilize photocatalysis to enhance the solar disinfection of water and provide an inexpensive, simple method of water disinfection, then it could help reduce the risk of waterborne disease. The second application is the use of photocatalytic coatings to combat healthcare associated infections. Two challenges are considered, i.e., the use of photocatalytic coatings to give “self-disinfecting” surfaces to reduce the risk of transmission of infection via environmental surfaces, and the use of photocatalytic coatings for the decontamination and disinfection of medical devices. In the final section, the development of novel photocatalytic materials for use in disinfection applications is reviewed, taking account of materials, developed for other photocatalytic applications, but which may be transferable for disinfection purposes.

  9. Efficiency of hydrogen peroxide in improving disinfection of ICU rooms.

    Science.gov (United States)

    Blazejewski, Caroline; Wallet, Frédéric; Rouzé, Anahita; Le Guern, Rémi; Ponthieux, Sylvie; Salleron, Julia; Nseir, Saad

    2015-02-02

    The primary objective of this study was to determine the efficiency of hydrogen peroxide (H₂O₂) techniques in disinfection of ICU rooms contaminated with multidrug-resistant organisms (MDRO) after patient discharge. Secondary objectives included comparison of the efficiency of a vaporizator (HPV, Bioquell) and an aerosolizer using H₂O₂, and peracetic acid (aHPP, Anios) in MDRO environmental disinfection, and assessment of toxicity of these techniques. This prospective cross-over study was conducted in five medical and surgical ICUs located in one University hospital, during a 12-week period. Routine terminal cleaning was followed by H₂O₂ disinfection. A total of 24 environmental bacteriological samplings were collected per room, from eight frequently touched surfaces, at three time-points: after patient discharge (T0), after terminal cleaning (T1) and after H₂O₂ disinfection (T2). In total 182 rooms were studied, including 89 (49%) disinfected with aHPP and 93 (51%) with HPV. At T0, 15/182 (8%) rooms were contaminated with at least 1 MDRO (extended spectrum β-lactamase-producing Gram-negative bacilli 50%, imipenem resistant Acinetobacter baumannii 29%, methicillin-resistant Staphylococcus aureus 17%, and Pseudomonas aeruginosa resistant to ceftazidime or imipenem 4%). Routine terminal cleaning reduced environmental bacterial load (P disinfection efficiency.

  10. Australian Government Balance Sheet Management

    OpenAIRE

    Wilson Au-Yeung; Jason McDonald; Amanda Sayegh

    2006-01-01

    Since almost eliminating net debt, the Australian Government%u2019s attention has turned to the financing of broader balance sheet liabilities, such as public sector superannuation. Australia will be developing a significant financial asset portfolio in the %u2018Future Fund%u2019 to smooth the financing of expenses through time. This raises the significant policy question of how best to manage the government balance sheet to reduce risk. This paper provides a framework for optimal balance sh...

  11. Energy information sheets, July 1998

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-07-01

    The National Energy Information Center (NEIC), as part of its mission, provides energy information and referral assistance to Federal, State, and local governments, the academic community, business and industrial organizations, and the public. The Energy Information Sheets was developed to provide general information on various aspects of fuel production, prices, consumption, and capability. Additional information on related subject matter can be found in other Energy Information Administration (EIA) publications as referenced at the end of each sheet.

  12. Energy information sheets, September 1996

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-09-01

    The National Energy Information Center (NEIC), as part of its mission, provides energy information and referral assistance to Federal, State, and local governments, the academic community, business and industrial organizations, and the public. The Energy Information Sheets was developed to provide general information on various aspects of fuel production, prices, consumption, and capability. Additional information on related subject matter can be found in other Energy Information Administration (EIA) publications as referenced at the end of each sheet.

  13. Zeolites modified with silver for the development of a water disinfection system

    International Nuclear Information System (INIS)

    Aparicio V, S.

    2013-01-01

    In spite of great strides that have been taken in sanitation technologies, there still exist health problems due to microbiological contamination by water. The waterborne diseases have not been completely eradicated and are a big problem of economic interest and health. Moreover, the microbicidal properties of silver have been used for a long time. The use of silver as a disinfectant has many advantages; for example it inhibits a wide spectrum of microorganisms, it has oligo dynamic properties and owing its mechanisms of cell inactivation, it also does not allow the emergence of new resistant strains. In the present research, the kinetics of water disinfection with silver has been investigated, to develop small system for water disinfection, based in silver modified Mexican clinoptilolite. The chemical species of silver play a significant role in the disinfection processes. For this reason, in this work, were both the Ag + and nanoparticles of Ag ο considered. The synthesis of nanoparticles of Ag ο woes performed by thermal and chemical reduction. It was found that the chemical reduction of Ag + to Ag ο was more efficient because it presented more defined nano structures and better distribution than those of thermal reduction. Clinoptilolite of Taxco (Guerrero) was chosen to exchange the native ions from the clinoptilolite by Ag + from the aqueous medium, or to deposit the nanoparticles of Ag ο on this surface. These silver modified zeolitic materials were characterized by scanning electron microscopy (Sem), elemental analyses (EDS), X-ray diffraction (XRD) and neutron activation analysis (NAA). The results showed that the crystallographic structure of the clinoptilolite did not change during thermal and chemical reduction treatments of Ag + to obtain the nanoparticles of Ag ο . The bactericide activity of the silver modified zeolitic materials (with Ag + or nanoparticles of Ag ο ) was evaluated on Escherichia coli Atcc 8739, in both distilled water and well

  14. Emergency procedures

    International Nuclear Information System (INIS)

    Abd Nasir Ibrahim; Azali Muhammad; Ab Razak Hamzah; Abd Aziz Mohamed; Mohammad Pauzi Ismail

    2004-01-01

    The following subjects are discussed - Emergency Procedures: emergency equipment, emergency procedures; emergency procedure involving X-Ray equipment; emergency procedure involving radioactive sources

  15. Radiation disinfection of sewage sludge and composting of the irradiated sludge

    International Nuclear Information System (INIS)

    Hashimoto, Shoji; Nishimura, Koichi; Watanabe, Hiromasa; Kawakami, Waichiro

    1985-01-01

    In the radiation disinfected sewage sludge, its stabilization is necessary with the composting. In this disinfected sludge, there is no need of keeping it at high temperature at the cost of fermentation velocity. The fermentation velocity can thus be set to obtain its maximum value. In sewage sludge utilization of farm land, to prevent the contamination with pathogenic bacteria and the secondary pollution, the radiation disinfection of dehydrated sludge and the composting of the disinfected sludge have been studied. The disinfection effect when an electron accelerator is used for the radiation source is described. Then, the composting of the disinfected sludge is described in chemical kinetics of the microorganisms. (Mori, K.)

  16. Theoretical model for the UV disinfection system in the operating ward of PZU 'Filip Vtori'

    International Nuclear Information System (INIS)

    Ilkov, Marjan

    2010-01-01

    Here we investigate the theoretical modeling of an UV disinfection system for the operating ward in PZU 'FILIP VTORI'. As nocosomial infections pose a serious threat to patients everywhere in the world, here the disinfection of the air and the surfaces is modeled and discussed. The surfaces are disinfected with direct illumination of open UV after hours system, UV curtains, overhead disinfection, floor disinfection and disinfection of the incoming air through the ventilation/air-condition system. From the results it can be seen that the concentrations of bacteria, fungi and viruses drop significantly which in turn should give a significant drop in a number of hospital acquired infections.(Author)

  17. FDTD modeling of thin impedance sheets

    Science.gov (United States)

    Luebbers, Raymond J.; Kunz, Karl S.

    1991-01-01

    Thin sheets of resistive or dielectric material are commonly encountered in radar cross section calculations. Analysis of such sheets is simplified by using sheet impedances. In this paper it is shown that sheet impedances can be modeled easily and accurately using Finite Difference Time Domain (FDTD) methods.

  18. In vitro study on the disinfectability of two split-septum needle-free connection devices using different disinfection procedures

    Directory of Open Access Journals (Sweden)

    Engelhart, Steffen

    2015-12-01

    Full Text Available This in vitro study investigated the external disinfection of two needle-free connection devices (NFC using Octeniderm (spraying and wiping technique vs. Descoderm pads (wiping technique. The split-septum membrane of the NFC was contaminated with >10 CFU . The efficacy of the disinfection at 30 sec. exposure time was controlled by taking a swab sample and by flushing the NFC with sterile 0.9% sodium chloride solution. Disinfection with octenidine dihydrochloride 0.1 g, 1-Propanol 30.0 g, and 2-Propanol 45.0 g in solution was highly effective (CFU reduction ≥4 log against both microorganisms, whereas the use of 63.1 g 2-Propanol in 100 ml solution led to residual contamination with . Our investigation underlines that (i in clinical practice disinfection of NFCs before use is mandatory, and that (ii details of disinfection technique are of utmost importance regarding their efficacy. Our investigation revealed no significant differences between both split-septum NFC types. Clinical studies are needed to confirm a possible superiority of disinfectants with long-lasting residual antimicrobial activity.

  19. On Jovian plasma sheet structure

    International Nuclear Information System (INIS)

    Khurana, K.K.; Kivelson, M.G.

    1989-01-01

    The authors evaluate several models of Jovian plasma sheet structure by determining how well they organize several aspects of the observed Voyager 2 magnetic field characteristics as a function of Jovicentric radial distance. It is shown that in the local time sector of the Voyager 2 outbound pass (near 0300 LT) the published hinged-magnetodisc models with wave (i.e., models corrected for finite wave velocity effects) are more successful than the published magnetic anomaly model in predicting locations of current sheet crossings. They also consider the boundary between the plasma sheet and the magnetotail lobe which is expected to vary slowly with radial distance. They use this boundary location as a further test of the models of the magnetotail. They show that the compressional MHD waves have much smaller amplitude in the lobes than in the plasma sheet and use this criterion to refine the identification of the plasma-sheet-lobe boundary. When the locations of crossings into and out of the lobes are examined, it becomes evident that the magnetic-anomaly model yields a flaring plasma sheet with a halfwidth of ∼ 3 R J at a radial distance of 20 R J and ∼ 12 R J at a radial distance of 100 R J . The hinged-magnetodisc models with wave, on the other hand, predict a halfwidth of ∼ 3.5 R J independent of distance beyond 20 R J . New optimized versions of the two models locate both the current sheet crossings and lobe encounters equally successfully. The optimized hinged-magnetodisc model suggests that the wave velocity decreases with increasing radial distance. The optimized magnetic anomaly model yields lower velocity contrast than the model of Vasyliunas and Dessler (1981)

  20. Automobile sheet metal part production with incremental sheet forming

    Directory of Open Access Journals (Sweden)

    İsmail DURGUN

    2016-02-01

    Full Text Available Nowadays, effect of global warming is increasing drastically so it leads to increased interest on energy efficiency and sustainable production methods. As a result of adverse conditions, national and international project platforms, OEMs (Original Equipment Manufacturers, SMEs (Small and Mid-size Manufacturers perform many studies or improve existing methodologies in scope of advanced manufacturing techniques. In this study, advanced manufacturing and sustainable production method "Incremental Sheet Metal Forming (ISF" was used for sheet metal forming process. A vehicle fender was manufactured with or without die by using different toolpath strategies and die sets. At the end of the study, Results have been investigated under the influence of method and parameters used.Keywords: Template incremental sheet metal, Metal forming

  1. Formation and occurrence of new polar iodinated disinfection byproducts in drinking water.

    Science.gov (United States)

    Pan, Yang; Li, Wenbin; An, Hao; Cui, Hao; Wang, Ying

    2016-02-01

    During drinking water disinfection, iodinated disinfection byproducts (I-DBPs) can be generated through reactions between iodide, disinfectants, and natural organic matter. Drinking water I-DBPs have been increasingly attracting attention as emerging organic pollutants as a result of their significantly higher toxicity and growth inhibition than their chloro- and bromo-analogues. In this study, by adopting ultra performance liquid chromatography/electrospray ionization-triple quadrupole mass spectrometry precursor ion scan, multiple reaction monitoring, and product ion scan analyses, 11 new polar I-DBPs with confirmed structures and eight new polar I-DBPs with proposed structures were detected in simulated drinking water samples. Chloramination of simulated raw waters containing natural organic matter with higher aromaticity produced higher levels of new phenolic I-DBPs. Formation of new polar I-DBPs and total organic iodine (TOI) was most favored in chloramination, followed by chlorine dioxide treatment, and relatively minor in chlorination. Lower pH in chloramination substantially enhanced the formation of new polar I-DBPs and TOI. NH2Cl and dissolved organic nitrogen could be important nitrogen sources and precursors for formation of the two new nitrogenous phenolic I-DBPs. Notably, in tap water samples collected from nine major cities located in the Yangtze River Delta region of China, seven of the 11 new polar I-DBPs with confirmed structures were detected at levels from 0.11 to 28 ng/L, and the two new nitrogenous phenolic I-DBPs were ubiquitous with concentrations from 0.12 to 24 ng/L, likely due to the relatively high dissolved organic nitrogen levels in regional source waters. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Overcoming the problem of residual microbial contamination in dental suction units left by conventional disinfection using novel single component suction handpieces in combination with automated flood disinfection.

    Science.gov (United States)

    Boyle, M A; O'Donnell, M J; Russell, R J; Galvin, N; Swan, J; Coleman, D C

    2015-10-01

    Decontaminating dental chair unit (DCU) suction systems in a convenient, safe and effective manner is problematic. This study aimed to identify and quantify the extent of the problems using 25 DCUs, methodically eliminate these problems and develop an efficient approach for reliable, effective, automated disinfection. DCU suction system residual contamination by environmental and human-derived bacteria was evaluated by microbiological culture following standard aspiration disinfection with a quaternary ammonium disinfectant or alternatively, a novel flooding approach to disinfection. Disinfection of multicomponent suction handpieces, assembled and disassembled, was also studied. A prototype manual and a novel automated Suction Tube Cleaning System (STCS) were developed and tested, as were novel single component suction handpieces. Standard aspiration disinfection consistently failed to decontaminate DCU suction systems effectively. Semi-confluent bacterial growth (101-500 colony forming units (CFU) per culture plate) was recovered from up to 60% of suction filter housings and from up to 19% of high and 37% of low volume suction hoses. Manual and automated flood disinfection of DCU suction systems reduced this dramatically (ranges for filter cage and high and low volume hoses of 0-22, 0-16 and 0-14CFU/plate, respectively) (P<0.0001). Multicomponent suction handpieces could not be adequately disinfected without prior removal and disassembly. Novel single component handpieces, allowed their effective disinfection in situ using the STCS, which virtually eliminated contamination from the entire suction system. Flood disinfection of DCU suction systems and single component handpieces radically improves disinfection efficacy and considerably reduces potential cross-infection and cross-contamination risks. DCU suction systems become heavily contaminated during use. Conventional disinfection does not adequately control this. Furthermore, multicomponent suction handpieces

  3. Uranium mining sites - Thematic sheets

    International Nuclear Information System (INIS)

    2009-01-01

    A first sheet proposes comments, data and key numbers about uranium extraction in France: general overview of uranium mining sites, status of waste rock and tailings after exploitation, site rehabilitation. The second sheet addresses the sources of exposure to ionizing radiations due to ancient uranium mining sites: discussion on the identification of these sources associated with these sites, properly due to mining activities or to tailings, or due to the transfer of radioactive substances towards water and to the contamination of sediments, description of the practice and assessment of radiological control of mining sites. A third sheet addresses the radiological exposure of public to waste rocks, and the dose assessment according to exposure scenarios: main exposure ways to be considered, studied exposure scenarios (passage on backfilled path and grounds, stay in buildings built on waste rocks, keeping mineralogical samples at home). The fourth sheet addresses research programmes of the IRSN on uranium and radon: epidemiological studies (performed on mine workers; on French and on European cohorts, French and European studies on the risk of lung cancer associated with radon in housing), study of the biological effects of chronic exposures. The last sheet addresses studies and expertises performed by the IRSN on ancient uranium mining sites in France: studies commissioned by public authorities, radioactivity control studies performed by the IRSN about mining sites, participation of the IRSN to actions to promote openness to civil society

  4. Enhanced composting of radiation disinfected sewage sludge

    International Nuclear Information System (INIS)

    Kawakami, W.; Hashimoto, S.

    1984-01-01

    Studies on isothermal composting of radiation disinfected sewage sludge and liquid chromatography of water extracts of the products were carried out. The optimum temperature and pH were around 50 deg C and 7 to 8, respectively. The repeated use of products as seeds increased the rate of CO 2 evolution. The rate reached a maximum within 10 hours and decreased rapidly, and the CO 2 evolution ceased after about 3 days. The conversion of organic carbon to carbon dioxide attained to about 40% for the repeated use of products as seeds at the optimum conditions. As long as seeds as available were used, no remarkable difference was found in the composting of unirradiated and irradiated sludges. The composting process using radiation, however, can be carried out at the optimum conditions and is expected to shorten the composting period, because it is not necessary to keep fermentation temperature higher to reduce pathogen in sludge. Liquid chromatographic studies of the products showed that low molecular components decreased and higher molecular ones increased with fermentation. An index expressing the degree of reduction of easily decomposable organics was presented. The index also showed that the optimum temperature for fermentation was 50 deg C. (author)

  5. Electron beam disinfection of sewage sludge

    International Nuclear Information System (INIS)

    Hashimoto, Shoji

    1992-01-01

    Electron beam treatment of dehydrated sewage sludge for safe reutilization was performed. Ranges of total bacterial counts and total coliforms in the sludge were from 1.5 x 10 8 to 1.6 x 10 9 and from 2.2 x 10 7 to 1.5 x 10 8 per wet gram, respectively. Total bacterial counts decreased about 5 log cycles after irradiating 5 kGy and irradiation with 2 kGy was enough to kill all coliforms in sewage sludge. The survival curves of total bacteria, obtained by irradiation in oxygen atmosphere, approached to that in nitrogen atmosphere with the increase of sludge thickness. No effects of dose rate and electron energy were found when the sludge layers were thin enough. Continuous disinfection of sewage sludge cake, with the maximum feed rate of 300 kg-sludge/hr, was successfully performed with a Cockcroft-Walton type electron accelerator, a sludge pump and a flat nozzle. (J.P.N.)

  6. Designing plasmas for chronic wound disinfection

    International Nuclear Information System (INIS)

    Nosenko, T; Shimizu, T; Morfill, G E

    2009-01-01

    Irradiation with low-temperature atmospheric-pressure plasma provides a promising method for chronic wound disinfection. To be efficient for this purpose, plasma should meet the following criteria: it should significantly reduce bacterial density in the wounded area, cause a long-term post-irradiation inhibition of bacterial growth, yet without causing any negative effect on human cells. In order to design plasmas that would satisfy these requirements, we assessed the relative contribution of different components with respect to bactericidal properties due to irradiation with argon plasma. We demonstrate that plasma-generated UV radiation is the main short-term sterilizing factor of argon plasma. On the other hand, plasma-generated reactive nitrogen species (RNS) and reactive oxygen species (ROS) cause a long-term 'after-irradiation' inhibition of bacterial growth and, therefore, are important for preventing wound recolonization with bacteria between two treatments. We also demonstrate that at certain concentrations plasma-generated RNS and ROS cause significant reduction of bacterial density, but have no adverse effect on human skin cells. Possible mechanisms of the different effects of plasma-generated reactive species on bacteria and human cells are discussed. The results of this study suggest that argon plasma for therapeutic purposes should be optimized in the direction of reducing the intensity of plasma-generated UV radiation and increasing the density of non-UV plasma products.

  7. Designing plasmas for chronic wound disinfection

    Energy Technology Data Exchange (ETDEWEB)

    Nosenko, T; Shimizu, T; Morfill, G E [Max-Planck Institute for Extraterrestrial Physics, Garching (Germany)], E-mail: tnosenko@mpe.mpg.de

    2009-11-15

    Irradiation with low-temperature atmospheric-pressure plasma provides a promising method for chronic wound disinfection. To be efficient for this purpose, plasma should meet the following criteria: it should significantly reduce bacterial density in the wounded area, cause a long-term post-irradiation inhibition of bacterial growth, yet without causing any negative effect on human cells. In order to design plasmas that would satisfy these requirements, we assessed the relative contribution of different components with respect to bactericidal properties due to irradiation with argon plasma. We demonstrate that plasma-generated UV radiation is the main short-term sterilizing factor of argon plasma. On the other hand, plasma-generated reactive nitrogen species (RNS) and reactive oxygen species (ROS) cause a long-term 'after-irradiation' inhibition of bacterial growth and, therefore, are important for preventing wound recolonization with bacteria between two treatments. We also demonstrate that at certain concentrations plasma-generated RNS and ROS cause significant reduction of bacterial density, but have no adverse effect on human skin cells. Possible mechanisms of the different effects of plasma-generated reactive species on bacteria and human cells are discussed. The results of this study suggest that argon plasma for therapeutic purposes should be optimized in the direction of reducing the intensity of plasma-generated UV radiation and increasing the density of non-UV plasma products.

  8. Sterilization and disinfection: the prevailing indifference

    International Nuclear Information System (INIS)

    Mirza, I.

    2007-01-01

    To evaluate the knowledge and attitude of health care professionals towards the process of sterilization and disinfection, and to check the adequacy of the reading material accessible to them. The study comprised of three components. In the first part, sections devoted to this subject in the popular books read by the students of operation theatre assistant course and students of diploma in general nursing were examined for adequacy and authenticity of information. In the second part, standard operating procedures were examined regarding sterilization of textile, rubber tubes of suction units and diathermy hand pieces of 20 operation theatres of three teaching hospital attached to undergraduate medical college of Punjab. In the third part of the study, working knowledge of 64 practicing operation theatre assistants and 57 practicing nurses was assessed through a questionnaire. It was found that popular books either did not contain the required information or the information provided was misleading or incorrect. Standard operating procedures for sterilization of selected items of all the operation theatres studied fell much below the standard of practice desired in the light of current knowledge and contemporary practices. Finally the working knowledge of the professionals studied was much below the bare minimum expected by the profession. There is a dire need for upgrading the knowledge and attitude of health care professionals regarding sterilization, besides improving the operation theatres sterilization procedures. (author)

  9. Patterning nonisometric origami in nematic elastomer sheets

    Science.gov (United States)

    Plucinsky, Paul; Kowalski, Benjamin A.; White, Timothy J.; Bhattacharya, Kaushik

    Nematic elastomers dramatically change their shape in response to diverse stimuli including light and heat. In this paper, we provide a systematic framework for the design of complex three dimensional shapes through the actuation of heterogeneously patterned nematic elastomer sheets. These sheets are composed of \\textit{nonisometric origami} building blocks which, when appropriately linked together, can actuate into a diverse array of three dimensional faceted shapes. We demonstrate both theoretically and experimentally that: 1) the nonisometric origami building blocks actuate in the predicted manner, 2) the integration of multiple building blocks leads to complex multi-stable, yet predictable, shapes, 3) we can bias the actuation experimentally to obtain a desired complex shape amongst the multi-stable shapes. We then show that this experimentally realized functionality enables a rich possible design landscape for actuation using nematic elastomers. We highlight this landscape through theoretical examples, which utilize large arrays of these building blocks to realize a desired three dimensional origami shape. In combination, these results amount to an engineering design principle, which we hope will provide a template for the application of nematic elastomers to emerging technologies.

  10. Prototypical model for tensional wrinkling in thin sheets

    KAUST Repository

    Davidovitch, B.; Schroll, R. D.; Vella, D.; Adda-Bedia, M.; Cerda, E. A.

    2011-01-01

    The buckling and wrinkling of thin films has recently seen a surge of interest among physicists, biologists, mathematicians, and engineers. This activity has been triggered by the growing interest in developing technologies at ever-decreasing scales and the resulting necessity to control the mechanics of tiny structures, as well as by the realization that morphogenetic processes, such as the tissue-shaping instabilities occurring in animal epithelia or plant leaves, often emerge from mechanical instabilities of cell sheets. Although the most basic buckling instability of uniaxially compressed plates was understood by Euler more than two centuries ago, recent experiments on nanometrically thin (ultrathin) films have shown significant deviations from predictions of standard buckling theory. Motivated by this puzzle, we introduce here a theoretical model that allows for a systematic analysis of wrinkling in sheets far from their instability threshold. We focus on the simplest extension of Euler buckling that exhibits wrinkles of finite length--a sheet under axisymmetric tensile loads. The first study of this geometry, which is attributed to Lamé, allows us to construct a phase diagram that demonstrates the dramatic variation of wrinkling patterns from near-threshold to far-from-threshold conditions. Theoretical arguments and comparison to experiments show that the thinner the sheet is, the smaller is the compressive load above which the far-from-threshold regime emerges. This observation emphasizes the relevance of our analysis for nanomechanics applications.

  11. Prototypical model for tensional wrinkling in thin sheets

    KAUST Repository

    Davidovitch, B.

    2011-10-31

    The buckling and wrinkling of thin films has recently seen a surge of interest among physicists, biologists, mathematicians, and engineers. This activity has been triggered by the growing interest in developing technologies at ever-decreasing scales and the resulting necessity to control the mechanics of tiny structures, as well as by the realization that morphogenetic processes, such as the tissue-shaping instabilities occurring in animal epithelia or plant leaves, often emerge from mechanical instabilities of cell sheets. Although the most basic buckling instability of uniaxially compressed plates was understood by Euler more than two centuries ago, recent experiments on nanometrically thin (ultrathin) films have shown significant deviations from predictions of standard buckling theory. Motivated by this puzzle, we introduce here a theoretical model that allows for a systematic analysis of wrinkling in sheets far from their instability threshold. We focus on the simplest extension of Euler buckling that exhibits wrinkles of finite length--a sheet under axisymmetric tensile loads. The first study of this geometry, which is attributed to Lamé, allows us to construct a phase diagram that demonstrates the dramatic variation of wrinkling patterns from near-threshold to far-from-threshold conditions. Theoretical arguments and comparison to experiments show that the thinner the sheet is, the smaller is the compressive load above which the far-from-threshold regime emerges. This observation emphasizes the relevance of our analysis for nanomechanics applications.

  12. The Occurrence and Comparative Toxicity of Haloacetaldehyde Disinfection Byproducts in Drinking Water

    Science.gov (United States)

    The introduction of drinking water disinfection greatly reduced the incidence of waterborne diseases. However, the reaction between disinfectants and natural organic matter in the source water can lead to an unintended consequence, which is the formation of drinking water disinfe...

  13. Disinfection of stabilization pond effluent by peracetic acid and sodium hypochlorite

    Directory of Open Access Journals (Sweden)

    Negar Rezania

    2013-01-01

    Conclusions: The study demonstrated that application of combined PAA and NaOCl in disinfecting the effluent of the stabilization pond will promote the efficiency of disinfection process in inactivating the coliform group bacteria and fecal streptococci.

  14. Residual viral and bacterial contamination of surfaces after cleaning and disinfection

    NARCIS (Netherlands)

    Tuladhar, E.; Hazeleger, W.C.; Koopmans, M.; Zwietering, M.H.; Beumer, R.R.; Duizer, E.

    2012-01-01

    Environmental surfaces contaminated with pathogens can be sources of indirect transmission, and cleaning and disinfection are common interventions focused on reducing contamination levels. We determined the efficacy of cleaning and disinfection procedures for reducing contamination by noroviruses,

  15. Integrated Disinfection By-Products Mixtures Research: Concentration by Reverse Osmosis Membrane Techniques of Disinfection By-Products from Water Disinfected by Chlorination and Ozonation/Postchlorination

    Science.gov (United States)

    To conduct the health-effect studies described in subsequent articles in this series, concentrated aqueous mixtures of disinfection by-products were required for the two water treatment trains described in the preceding article (Miltner et al., 2008). To accomplish this, the fini...

  16. Clinical and cost effectiveness of eight disinfection methods for terminal disinfection of hospital isolation rooms contaminated with Clostridium difficile 027.

    Science.gov (United States)

    Doan, L; Forrest, H; Fakis, A; Craig, J; Claxton, L; Khare, M

    2012-10-01

    Clostridium difficile spores can survive in the environment for months or years, and contaminated environmental surfaces are important sources of nosocomial C. difficile transmission. To compare the clinical and cost effectiveness of eight C. difficile environmental disinfection methods for the terminal cleaning of hospital rooms contaminated with C. difficile spores. This was a novel randomized prospective study undertaken in three phases. Each empty hospital room was disinfected, then contaminated with C. difficile spores and disinfected with one of eight disinfection products: hydrogen peroxide vapour (HPV; Bioquell Q10) 350-700 parts per million (ppm); dry ozone at 25 ppm (Meditrox); 1000 ppm chlorine-releasing agent (Actichlor Plus); microfibre cloths (Vermop) used in combination with and without a chlorine-releasing agent; high temperature over heated dry atomized steam cleaning (Polti steam) in combination with a sanitizing solution (HPMed); steam cleaning (Osprey steam); and peracetic acid wipes (Clinell). Swabs were inoculated on to C. difficile-selective agar and colony counts were performed pre and post disinfection for each method. A cost-effectiveness analysis was also undertaken comparing all methods to the current method of 1000 ppm chlorine-releasing agent (Actichlor Plus). Products were ranked according to the log(10) reduction in colony count from contamination phase to disinfection. The three statistically significant most effective products were hydrogen peroxide (2.303); 1000 ppm chlorine-releasing agent (2.223) and peracetic acid wipes (2.134). The cheaper traditional method of using a chlorine-releasing agent for disinfection was as effective as modern methods. Copyright © 2012 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  17. Root-growth-inhibiting sheet

    Science.gov (United States)

    Burton, F.G.; Cataldo, D.A.; Cline, J.F.; Skiens, W.E.; Van Voris, P.

    1993-01-26

    In accordance with this invention, a porous sheet material is provided at intervals with bodies of a polymer which contain a 2,6-dinitroaniline. The sheet material is made porous to permit free passage of water. It may be either a perforated sheet or a woven or non-woven textile material. A particularly desirable embodiment is a non-woven fabric of non-biodegradable material. This type of material is known as a geotextile'' and is used for weed control, prevention of erosion on slopes, and other landscaping purposes. In order to obtain a root repelling property, a dinitroaniline is blended with a polymer which is attached to the geotextile or other porous material.

  18. Optimal swimming of a sheet.

    Science.gov (United States)

    Montenegro-Johnson, Thomas D; Lauga, Eric

    2014-06-01

    Propulsion at microscopic scales is often achieved through propagating traveling waves along hairlike organelles called flagella. Taylor's two-dimensional swimming sheet model is frequently used to provide insight into problems of flagellar propulsion. We derive numerically the large-amplitude wave form of the two-dimensional swimming sheet that yields optimum hydrodynamic efficiency: the ratio of the squared swimming speed to the rate-of-working of the sheet against the fluid. Using the boundary element method, we show that the optimal wave form is a front-back symmetric regularized cusp that is 25% more efficient than the optimal sine wave. This optimal two-dimensional shape is smooth, qualitatively different from the kinked form of Lighthill's optimal three-dimensional flagellum, not predicted by small-amplitude theory, and different from the smooth circular-arc-like shape of active elastic filaments.

  19. Root-growth-inhibiting sheet

    Science.gov (United States)

    Burton, Frederick G.; Cataldo, Dominic A.; Cline, John F.; Skiens, W. Eugene; Van Voris, Peter

    1993-01-01

    In accordance with this invention, a porous sheet material is provided at intervals with bodies of a polymer which contain a 2,6-dinitroaniline. The sheet material is made porous to permit free passage of water. It may be either a perforated sheet or a woven or non-woven textile material. A particularly desirable embodiment is a non-woven fabric of non-biodegradable material. This type of material is known as a "geotextile" and is used for weed control, prevention of erosion on slopes, and other landscaping purposes. In order to obtain a root repelling property, a dinitroaniline is blended with a polymer which is attached to the geotextile or other porous material.

  20. Selection criteria for water disinfection techniques in agricultural practices.

    Science.gov (United States)

    Haute, Sam van; Sampers, Imca; Jacxsens, Liesbeth; Uyttendaele, Mieke

    2015-01-01

    This paper comprises a selection tool for water disinfection methods for fresh produce pre- and postharvest practices. A variety of water disinfection technologies is available on the market and no single technology is the best choice for all applications. It can be difficult for end users to choose the technology that is best fit for a specific application. Therefore, the different technologies were characterized in order to identify criteria that influence the suitability of a technology for pre- or postharvest applications. Introduced criteria were divided into three principal components: (i) criteria related to the technology and which relate to the disinfection efficiency, (ii) attention points for the management and proper operation, and (iii) necessities in order to sustain the operation with respect to the environment. The selection criteria may help the end user of the water disinfection technology to obtain a systematic insight into all relevant aspects to be considered for preliminary decision making on which technologies should be put to feasibility testing for water disinfection in pre- and postharvest practices of the fresh produce chain.

  1. Microbiological evaluation of ultrasonic nebulization for disinfecting dental impressions.

    Science.gov (United States)

    Mendonca, Marcio Jose; Rafael, Renata Santos; Camilotti, Veridiana; Menolli, Rafael Andrade; Sicoli, Eliseu Augusto; Teixeira, Nancielli; Sinhoreti, Mario Alexandre Coelho

    2013-07-01

    Disinfecting dental impressions is necessary to decrease the risk of cross-contamination in dental offices. Ultrasonic nebulization has been mentioned as a microbicidal technique that can be used to disinfect contaminated dental impressions. This study compared the microbicidal effect of 2% glutaraldehyde and 0.2% peracetic acid for the disinfection of dental impressions made with vinyl polysiloxane, using 2 disinfection methods: immersion and ultrasonic nebulization. Bactericial efficacy was examined using Staphylococcus aureus and Bacillus atrophaeus as indicators. Thirty impressions were obtained and distributed randomly in 5 groups (n = 6). Group 1 was immersed in 2% glutaraldehyde immersion for 10 minutes, Group 2 was immersed in 0.2% peracetic acid for 10 minutes, Group 3 underwent ultrasonic nebulization for 10 minutes in 2% glutaraldehyde solution, Group 4 underwent ultrasonic nebulization for 10 minutes in 0.2% peracetic acid solution, and Group 5 was a control group that received no disinfectant. Both solutions experienced a 100% reduction in microorganisms following ultrasonic nebulization, as did peracetic acid following immersion; however, immersion in glutaraldehyde demonstrated lower values of reduction in B atrophaeus group, with a statistically significant difference compared with the other experimental groups.

  2. Ultraviolet (UV) disinfection of grey water: particle size effects.

    Science.gov (United States)

    Winward, G P; Avery, L M; Stephenson, T; Jefferson, B

    2008-02-01

    The impact of water quality on the ultraviolet (UV) disinfection of grey water was investigated with reference to urban water reuse. Direct UV disinfection of grey water did not meet the stringent California State Title 22 criteria for unrestricted urban water reuse due to the presence of particulate material ranging from or = 2000 microm in size. Grey water was manipulated by settling to produce fractions of varying particle size distributions and blending was employed post-disinfection to extract particle-associated coliforms (PACs). The efficacy of UV disinfection was found to be linked to the particle size of the grey water fractions. The larger particle size fractions with a mean particle size of 262 microm and above were observed to shield more coliforms from UV light than did the smaller particles with a mean particle size below 119 microm. Up to 70% of total coliforms in the larger particle size fractions were particle-associated following a UV dose (fluence) of 260 mJ.cm(-2) and would remain undetected by standard coliform enumeration techniques. Implications for urban water reuse are discussed and recommendations made for grey water treatment to ensure removal of particle-associated indicator bacteria and pathogens prior to UV disinfection.

  3. Fresh water disinfection by pulsed low electric field

    International Nuclear Information System (INIS)

    Zheng, C; Xu, Y; Liu, Z; Yan, K

    2013-01-01

    In this paper, we describe a pulsed low electric field process for water disinfection. Electric intensity of 0.6–1.7 kV cm −1 is applied. Experiments are performed with a 1.2 L axis-cylinder reactor. A bipolar pulsed power source with pulsed width of 25 μs and frequency of 100–3000 Hz is used. Water conductivity of 3–200 μs cm −1 is investigated, which can significantly affect pulsed voltage-current waveforms and injected energy. Energy per pulse rises with increased water conductivity. The initial E. Coli density and water conductivity are two major factors influencing the disinfection. No disinfection effect is performed with deionized water of 3 μs cm −1 . When water conductivity is 25 μs cm −1 and bacteria density is 10 4 –10 6 cfu ml −1 , significant disinfection effect is observed. More than 99% of the cells can be disinfected with an energy density of less than 70 J ml −1 , while water temperature is below 30 °C.

  4. [Decontamination of dental unit waterlines using disinfectants and filters].

    Science.gov (United States)

    Monarca, S; Garusi, G; Gigola, P; Spampinato, L; Zani, C; Sapelli, P L

    2002-10-01

    Bacterial contamination of the dental unit water system can become a health problem for patients, particularly if they are immunodepressed. The present study has had the purpose of evaluating the effectiveness of methods of chemical decontamination using different disinfectants (peracetic acid, hydrogen peroxide, silver salts, chloramine T, glutaraldehyde T4) and methods of physical decontamination using synthetic membranes for the filtration of water. A preliminary removal procedure of the biofilm present in the waterline has been followed in a dental unit prepared on purpose for the research; subsequently different 2-week long maintenance procedures were applied using disinfectants injected by a pump and finally the bacterial contamination of the water flowing from the waterline was evaluated. The physical decontamination was performed using 0.22 mm membrane filters, which have been installed also in another dental unit, and the filtered water was analyzed to detect bacterial contamination. The preliminary procedure of biofilm removal succeeded obtaining germ-free water. Among the disinfectants used for the maintenance of the water quality only glutaraldehyde T4 was able to reduce the bacterial contamination under the limit suggested by the ADA. The membrane filter system was not able to purify the water, but when a disinfectant (peracetic acid) was used in the last part of the waterline good results were obtained. At present no decontamination system of dental waterline is available, and glutaraldehyde T4 seems to be the best disinfectant only if integrated with periodic biofilm removal for the maintenance of the water quality.

  5. Effectiveness of Four Disinfectants against Ebola Virus on Different Materials

    Directory of Open Access Journals (Sweden)

    Sophie Smither

    2016-07-01

    Full Text Available The West Africa Ebola virus (EBOV outbreak has highlighted the need for effective disinfectants capable of reducing viral load in a range of sample types, equipment and settings. Although chlorine-based products are widely used, they can also be damaging to equipment or apparatus that needs continuous use such as aircraft use for transportation of infected people. Two aircraft cleaning solutions were assessed alongside two common laboratory disinfectants in a contact kill assay with EBOV on two aircraft relevant materials representative of a porous and non-porous surface. A decimal log reduction of viral titre of 4 is required for a disinfectant to be deemed effective and two of the disinfectants fulfilled this criteria under the conditions tested. One product, Ardrox 6092, was found to perform similarly to sodium hypochlorite, but as it does not have the corrosive properties of sodium hypochlorite, it could be an alternative disinfectant solution to be used for decontamination of EBOV on sensitive apparatus.

  6. UV disinfection for reuse applications in North America.

    Science.gov (United States)

    Sakamoto, G; Schwartzel, D; Tomowich, D

    2001-01-01

    In an effort to conserve and protect limited water resources, the States of Florida and California have actively promoted wastewater reclamation and have implemented comprehensive regulations covering a range of reuse applications. Florida has a semi-tropical climate with heavy summer rains that are lost due to run off and evaporation. Much of California is arid and suffers periodic droughts, low annual rainfall and depleted ground water supplies. The high population density combined with heavy irrigation demands has depleted ground water supplies resulting in salt-water intrusion. During the past decade, Florida reuse sites have increased dramatically from 118 to 444 plants representing a total flow capacity of 826 MGD. California presently has over 250 plants producing 1 BGD with a projected increase of 160 sites over the next 20 years. To prevent the transmission of waterborne diseases, disinfection of reclaimed water is controlled by stringent regulations. Many states regulate wastewater treatment processes, nutrient removal, final effluent quality and disinfection criteria based upon the specific reuse application. As a rule, the resulting effluents have low turbidity and suspended solids. For such effluents, UV technology can economically achieve the most stringent disinfection targets that are required by the States of California and Florida for restricted and unrestricted reuse. This paper compares UV disinfection for wastewater reuse sites in California and Florida and discusses the effect of effluent quality on UV disinfection.

  7. Cleaning, disinfection and sterilization of surface prion contamination.

    Science.gov (United States)

    McDonnell, G; Dehen, C; Perrin, A; Thomas, V; Igel-Egalon, A; Burke, P A; Deslys, J P; Comoy, E

    2013-12-01

    Prion contamination is a risk during device reprocessing, being difficult to remove and inactivate. Little is known of the combined effects of cleaning, disinfection and sterilization during a typical reprocessing cycle in clinical practice. To investigate the combination of cleaning, disinfection and/or sterilization on reducing the risk of surface prion contamination. In vivo test methods were used to study the impact of cleaning alone and cleaning combined with thermal disinfection and high- or low-temperature sterilization processes. A standardized test method, based on contamination of stainless steel wires with high titres of scrapie-infected brain homogenates, was used to determine infectivity reduction. Traditional chemical methods of surface decontamination against prions were confirmed to be effective, but extended steam sterilization was more variable. Steam sterilization alone reduced the risk of prion contamination under normal or extended exposure conditions, but did show significant variation. Thermal disinfection had no impact in these studies. Cleaning with certain defined formulations in combination with steam sterilization can be an effective prion decontamination process, in particular with alkaline formulations. Low-temperature, gaseous hydrogen peroxide sterilization was also confirmed to reduce infectivity in the presence and absence of cleaning. Prion decontamination is affected by the full reprocessing cycle used on contaminated surfaces. The correct use of defined cleaning, disinfection and sterilization methods as tested in this report in the scrapie infectivity assay can provide a standard precaution against prion contamination. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  8. Modelling the Antarctic Ice Sheet

    DEFF Research Database (Denmark)

    Pedersen, Jens Olaf Pepke; Holm, A.

    2015-01-01

    to sea level high stands during past interglacial periods. A number of AIS models have been developed and applied to try to understand the workings of the AIS and to form a robust basis for future projections of the AIS contribution to sea level change. The recent DCESS (Danish Center for Earth System......The Antarctic ice sheet is a major player in the Earth’s climate system and is by far the largest depository of fresh water on the planet. Ice stored in the Antarctic ice sheet (AIS) contains enough water to raise sea level by about 58 m, and ice loss from Antarctica contributed significantly...

  9. Sheet Beam Klystron Instability Analysis

    International Nuclear Information System (INIS)

    Bane, K.

    2009-01-01

    Using the principle of energy balance we develop a 2D theory for calculating growth rates of instability in a two-cavity model of a sheet beam klystron. An important ingredient is a TE-like mode in the gap that also gives a longitudinal kick to the beam. When compared with a self-consistent particle-in-cell calculation, with sheet beam klystron-type parameters, agreement is quite good up to half the design current, 65 A; at full current, however, other, current-dependent effects come in and the results deviate significantly

  10. The social balance sheet 2004

    OpenAIRE

    Ph. Delhez; P. Heuse

    2005-01-01

    Each year, in the 4th quarter’s Economic Review, the National Bank examines the provisional results of the social balance sheets. As all the social balance sheets are not yet available for 2004, the study is based on a limited population of enterprises, compiled according to the principle of a constant sample. This population is made up of 38,530 enterprises employing around 1,331,000 workers in 2004. The main results of the analysis, in terms of employment, working hours, labour cost and tra...

  11. Evaluation of 5 Cleaning and Disinfection Methods for Nets Used to Collect Zebrafish (Danio rerio)

    OpenAIRE

    Collymore, Chereen; Porelli, Gina; Lieggi, Christine; Lipman, Neil S

    2014-01-01

    Few standardized methods of cleaning and disinfecting equipment in zebrafish facilities have been published, even though the effectiveness of these procedures is vital to preventing the transmission of pathogenic organisms. Four chemical disinfectants and rinsing with municipal tap water were evaluated for their ability to disinfect nets used to capture zebrafish. The disinfectants included benzalkonium chloride+methylene blue, sodium hypochlorite, chlorine dioxide, and potassium peroxymonosu...

  12. Effect of alginate chemical disinfection on bacterial count over gypsum cast

    OpenAIRE

    Haralur, Satheesh B.; Al-Dowah, Omir S.; Gana, Naif S.; Al-Hytham, Abdullah

    2012-01-01

    PURPOSE To evaluate the efficacy of sodium hypochlorite (1 : 10) and iodophor disinfectants on alginate impressions along with their effect on the survived bacterium count on the gypsum cast. MATERIALS AND METHODS Four alginate impression on each dentate patients were made, of which Group I were not washed or disinfected, Group II impressions were merely washed with water, Group III were disinfected by spraying with sodium hypochlorite (1 : 10), Group IV were disinfected with iodophor (1 : 21...

  13. Conventional and Alternative Disinfection Methods of Legionella in Water Distribution Systems – Review

    Directory of Open Access Journals (Sweden)

    Pūle Daina

    2016-12-01

    Full Text Available Prevalence of Legionella in drinking water distribution systems is a widespread problem. Outbreaks of Legionella caused diseases occur despite various disinfectants are used in order to control Legionella. Conventional methods like thermal disinfection, silver/copper ionization, ultraviolet irradiation or chlorine-based disinfection have not been effective in the long term for control of biofilm bacteria. Therefore, research to develop more effective disinfection methods is still necessary.

  14. Inactivation of various influenza strains to model avian influenza (Bird Flu) with various disinfectant chemistries.

    Energy Technology Data Exchange (ETDEWEB)

    Oberst, R. D.; Bieker, Jill Marie; Souza, Caroline Ann

    2005-12-01

    Due to the grave public health implications and economic impact possible with the emergence of the highly pathogenic avian influenza A isolate, H5N1, currently circulating in Asia we have evaluated the efficacy of various disinfectant chemistries against surrogate influenza A strains. Chemistries included in the tests were household bleach, ethanol, Virkon S{reg_sign}, and a modified version of the Sandia National Laboratories developed DF-200 (DF-200d, a diluted version of the standard DF-200 formulation). Validation efforts followed EPA guidelines for evaluating chemical disinfectants against viruses. The efficacy of the various chemistries was determined by infectivity, quantitative RNA, and qualitative protein assays. Additionally, organic challenges using combined poultry feces and litter material were included in the experiments to simulate environments in which decontamination and remediation will likely occur. In all assays, 10% bleach and Sandia DF-200d were the most efficacious treatments against two influenza A isolates (mammalian and avian) as they provided the most rapid and complete inactivation of influenza A viruses.

  15. The Occurrence and Toxicity of Disinfection Byproducts in European Drinking Waters in Relation with the HIWATE Epidemiology Study

    Science.gov (United States)

    Jeong, Clara H.; Wagner, Elizabeth D.; Siebert, Vincent R.; Anduri, Sridevi; Richardson, Susan D.; Daiber, Eric J.; McKague, A. Bruce; Kogevinas, Manolis; Villanueva, Cristina M.; Goslan, Emma H.; Luo, Wentai; Isabelle, Lorne M.; Pankow, James F.; Grazuleviciene, Regina; Cordier, Sylvaine; Edwards, Susan C.; Righi, Elena; Nieuwenhuijsen, Mark J.; Plewa, Michael J.

    2012-01-01

    The HIWATE (Health Impacts of long-term exposure to disinfection byproducts in drinking WATEr) project was a systematic analysis that combined the epidemiology on adverse pregnancy outcomes and other health effects with long term exposure to low levels of drinking water disinfection byproducts (DBPs) in the European Union. The present study focused on the relationship of the occurrence and concentration of DBPs with in vitro mammalian cell toxicity. Eleven drinking water samples were collected from 5 European countries. Each sampling location corresponded with an epidemiological study for the HIWATE program. Over 90 DBPs were identified; the range in the number of DBPs and their levels reflected the diverse collection sites, different disinfection processes, and the different characteristics of the source waters. For each sampling site, chronic mammalian cell cytotoxicity correlated highly with the numbers of DBPs identified and the levels of DBP chemical classes. Although there was a clear difference in the genotoxic responses among the drinking waters, these data did not correlate as well with the chemical analyses. Thus, the agents responsible for the genomic DNA damage observed in the HIWATE samples may be due to unresolved associations of combinations of identified DBPs, unknown emerging DBPs that were not identified, or other toxic water contaminants. This study represents the first to integrate quantitative in vitro toxicological data with analytical chemistry and human epidemiologic outcomes for drinking water DBPs. PMID:22958121

  16. 40 CFR 141.709 - Developing the disinfection profile and benchmark.

    Science.gov (United States)

    2010-07-01

    ... Cryptosporidium Disinfection Profiling and Benchmarking Requirements § 141.709 Developing the disinfection profile...) of the water before or at the first customer and prior to each additional point of disinfectant...) before or at the first customer during peak hourly flow. (ii) Determine successive CTcalc/CT99.9 values...

  17. 9 CFR 51.8 - Disinfection of premises, conveyances, and materials.

    Science.gov (United States)

    2010-01-01

    ... facilities, conveyances, or other materials on the premises that would require such cleaning and disinfection... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Disinfection of premises, conveyances... ANIMALS DESTROYED BECAUSE OF BRUCELLOSIS Indemnity for Cattle, Bison, and Swine § 51.8 Disinfection of...

  18. 9 CFR 91.18 - Cleaning and disinfection of transport carriers for export.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Cleaning and disinfection of transport....18 Cleaning and disinfection of transport carriers for export. All fittings, utensils and equipment... port. Such disinfection of halters, ropes, and similar equipment used in handling and tying of animals...

  19. 9 CFR 77.19 - Cleaning and disinfection of premises, conveyances, and materials.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Cleaning and disinfection of premises... PRODUCTS TUBERCULOSIS Cattle and Bison § 77.19 Cleaning and disinfection of premises, conveyances, and... health officials. Cleaning and disinfection must be completed before the premises, conveyances, or...

  20. 9 CFR 53.7 - Disinfection of premises, conveyances, and materials.

    Science.gov (United States)

    2010-01-01

    ... least 7 days following such cleaning and disinfection, unless the Administrator determines that a... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Disinfection of premises, conveyances... LIVESTOCK OR POULTRY § 53.7 Disinfection of premises, conveyances, and materials. All premises, including...

  1. 9 CFR 77.41 - Cleaning and disinfection of premises, conveyances, and materials.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Cleaning and disinfection of premises... PRODUCTS TUBERCULOSIS Captive Cervids § 77.41 Cleaning and disinfection of premises, conveyances, and... health officials. Cleaning and disinfection must be completed before the premises, conveyances, or...

  2. Genotoxicity of the disinfection by-products resulting from peracetic acid- or hypochlorite-disinfected sewage wastewater.

    Science.gov (United States)

    Crebelli, R; Conti, L; Monarca, S; Feretti, D; Zerbini, I; Zani, C; Veschetti, E; Cutilli, D; Ottaviani, M

    2005-03-01

    Wastewater disinfection is routinely carried out to prevent the spread of human pathogens present in wastewater effluents. To this aim, chemical and physical treatments are applied to the effluents before their emission in water bodies. In this study, the influence of two widely used disinfectants, peracetic acid (PAA) and sodium hypochlorite (NaClO), on the formation of mutagenic by-products was investigated. Wastewater samples were collected before and after disinfection, in winter and in summer, at a pilot plant installed in a municipal wastewater-treatment plant. Samples were adsorbed using silica C18 cartridges and the concentrates were tested for mutagenicity in the Salmonella typhimurium reversion test with strains TA98 and TA100. Non-concentrated water samples were tested with two plant genotoxicity assays (the Allium cepa root anaphase aberration test and the Tradescantia/micronucleus test). Mutagenicity assays in bacteria and in Tradescantia showed borderline mutagenicity in some of the wastewater samples, independent of the disinfection procedure applied. Negative results were obtained in the A. cepa anaphase aberration test. These results indicate that, in the conditions applied, wastewater disinfection with PAA and NaClO does not lead to the formation of significant amounts of genotoxic by-products.

  3. Application of neutral electrolyzed water to disinfection of alginate impression.

    Science.gov (United States)

    Nagamatsu, Yuki; Chen, Ker-Kong; Nagamatsu, Hiroshi; Kozono, Yoshio; Shimizu, Hiroshi

    2016-01-01

    Neutral electrolyzed water was developed with new concepts of long-term good durability and minimum corrosiveness to metal in addition to its excellent bactericidal activities similar to acid type of electrolyzed waters. The present study examined the bactericidal effects of the neutral electrolyzed water on disinfection of the alginate impression of a dental arch model contaminated by bacteria. Only 1-min immersion in neutral electrolyzed water could sufficiently disinfect the alginate impression including the metallic tray under ultrasonic with no significant differences from acid electrolyzed waters. No bactericidal effects were found in any electrolyzed water when used as mixing water. Considering the advantages and disadvantages of each electrolyzed water in a comprehensive way, it was suggested that neutral electrolyzed water may be the most appropriate for the disinfection of alginate impression.

  4. Drinking water and biofilm disinfection by Fenton-like reaction.

    Science.gov (United States)

    Gosselin, F; Madeira, L M; Juhna, T; Block, J C

    2013-10-01

    A Fenton-like disinfection process was conducted with Fenton's reagent (H2O2) at pH 3 or 5 on autochthonous drinking water biofilms grown on corroded or non-corroded pipe material. The biofilm disinfection by Fenton-like oxidation was limited by the low content of iron and copper in the biomass grown on non-corroded plumbing. It was slightly improved by spiking the distribution system with some additional iron source (soluble iron II or ferrihydrite particles appeared as interesting candidates). However successful in situ disinfection of biofilms was only achieved in fully corroded cast iron pipes using H2O2 and adjusting the pH to 5. These new results provide additional support for the use of Fenton's processes for cleaning drinking water distribution systems contaminated with biological agents or organics. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Disinfection of bacteria attached to granular activated carbon.

    Science.gov (United States)

    LeChevallier, M W; Hassenauer, T S; Camper, A K; McFeters, G A

    1984-01-01

    Heterotrophic plate count bacteria, coliform organisms, and pathogenic microorganisms attached to granular activated carbon particles were examined for their susceptibility to chlorine disinfection. When these bacteria were grown on carbon particles and then disinfected with 2.0 mg of chlorine per liter (1.4 to 1.6 mg of free chlorine residual per liter after 1 h) for 1 h, no significant decrease in viable counts was observed. Washed cells attached to the surface of granular activated carbon particles showed similar resistance to chlorine, but a progressive increase in sublethal injury was found. Observations made by scanning electron microscope indicated that granular activated carbon was colonized by bacteria which grow in cracks and crevices and are coated by an extracellular slime layer. These data suggest a possible mechanism by which treatment and disinfection barriers can be penetrated and pathogenic bacteria may enter drinking water supplies. Images PMID:6508306

  6. Solar water disinfecting system using compound parabolic concentrating collector

    Energy Technology Data Exchange (ETDEWEB)

    El-Ghetany, H.H.; Saitoh, T.S. [Tohoku Univ., Sendai (Japan)

    2000-05-31

    Solar water disinfection is an alternative technology using solar radiation and thermal treatment to inactivate and destroy pathogenic microorganisms present in water. The Compound Parabolic Concentrating, (CPC) collector can be used as an efficient key component for solar disinfectanting system. Two types of the CPC collectors are studied, namely the transparent-tube and the Copper-tube CPC collector. It is found that after 30 minutes of exposing the water sample to solar radiation or heating it up to 65 degree C for a few minuets all the coliform bacterial present in the contaminated water sample were completely eliminated. In this article, the effect of water temperature on the disinfecting process was presented. Thermal and micro-biological measurements were also made to evaluate the system performance. (author)

  7. Disinfection procedures for in vitro propagation of Anthurium

    Directory of Open Access Journals (Sweden)

    Silva Jaime A. Teixeira da

    2015-06-01

    Full Text Available Disinfection of plant material is the most important step of the tissue culture protocol. In this process, an attempt is made to eliminate microbial contaminants from the surface and interior of plant material, thus giving the explant a fighting chance at survival in vitro. Initial cultures of Anthurium species and cultivars, which are usually established from ex vitro material grown in a greenhouse, pots or in the field, easily contaminate the in vitro milieu. This review highlights the differences in disinfection protocols that exist for different species or cultivars of Anthurium. The protocol needs to be adjusted based on the material used: spadices, spathes, seeds, leaves, or roots. Regrettably, most of the currently published protocols, derived from a literature that spans over 100 published papers, have numerous weaknesses and flaws in the information provided pertaining to disinfection and infection levels. Advice for future Anthurium researchers should thus be followed cautiously.

  8. Biophysical methods for disinfection and stimulation of wheat seeds

    International Nuclear Information System (INIS)

    Marinkovic, S.; Marinkovic, B.

    2007-01-01

    In this paper we are shown results of applying electron treatment (disinfection of seed by electrons), and RIES method (electromagnetic seed stimulation). Four cultivars of wheat were used in this trial: Renesansa, Durumko, NS-Rana 5 and Sonata. Seed was treated with fast electrons and just before sowing stimulated by ultra low frequency electromagnetic field (from 0 to 100 Hz). For seed disinfection was used chemical treatment as well, as control variant. Control variant for all treatments was seed without any disinfection. The highest number of spikelets per spike was obtained at variant H+RIES. The highest spike length was obtained at variants e sup(-) + RIES and control. At variant H+RIES was achieved the highest grain number. Treatment H had influence on decreasing of grain mass per spike in relation to control variant, for significant value of 0.15 g. The highest grain mass per spike was obtained at variant e sup(-) + RIES

  9. A novel cupping-assisted plasma treatment for skin disinfection

    Science.gov (United States)

    Xiong, Zilan; Graves, David B.

    2017-02-01

    A novel plasma treatment method/plasma source called cupping-assisted plasma treatment/source for skin disinfection is introduced. The idea combines ancient Chinese ‘cupping’ technology with plasma sources to generate active plasma inside an isolated, pressure-controlled chamber attached to the skin. Advantages of lower pressure include reducing the threshold voltage for plasma ignition and improving the spatial uniformity of the plasma treatment. In addition, with reduced pressure inside the cup, skin pore permeability might be increased and it improves attachment of the plasma device to the skin. Moreover, at a given pressure, plasma-generated active species are restricted inside the cup, raising local reactive species concentration and enhancing the measured surface disinfection rate. A surface micro-discharge (SMD) device is used as an example of a working plasma source. We report discharge characteristics and disinfection efficiency as a function of pressure and applied voltage.

  10. [Disinfectants for the skin of premature].

    Science.gov (United States)

    Cucurachi, G; Tuoto, M G

    2010-06-01

    Nosocomial infections are among the leading causes of mortality and morbidity in neonatal intensive care units. Prevention of healthcare-associated infections is based on strategies that aim to limit susceptibility to infections by enhancing host defences, interrupting trasmission of organisms by healthcare workers and by promoting the judicious use of antimicrobials. Strategies for the prevention of nosocomial infections include hand hygiene practices, prevention of central venous (cvc)-related bloodstream infections, judicious use of antimicrobials for therapy, enhancement of host defences, skin care and early enteral feeding with human milk. Major concerns about the use of alcoholic chlorhexidine are for the high risk of skin burns in extremely premature infants during the first days of life, when the skin is thin and not fully keratinesed. Aqueous chlorhexidine could be less irritant when used in very low birthweigth infants and thus could represent a good option. A recent prospective trial of adult patients showed similar effectiveness of alcoholic and aqueos solutions of chlorexidine. However, to date no study evaluated whether the aqueos formulation is less harmful and as effective as the alcoholic formulation in neonatal infants. The lack of evidence for neonatal patients prompts urgent need for large randomised controlled trials comparing effectiveness and safety of different skin disinfectants before CVC placement in neonates and particulary in very low birth-weight infants. Nosocomial infections are still of the most serious problems for the neonatal intensive care unit. Therefore every effort must be implemented to reduce the incidence of these infections, can not be considered a toll required hospitalization, as it may not be acceptable for a place of shelter and care as the hospital may itself be a source of disease.

  11. Generation of ozone foam and its application for disinfection

    Science.gov (United States)

    Hiragaki, Keisuke; Ishimaru, Tomiya; Nakanishi, Masaru; Muraki, Ryouji; Nieda, Masanori; Yamabe, Chobei

    2015-07-01

    Generated ozone foam was applied to the disinfection of Pseudomonas fluorescens. The effect of disinfection has been confirmed experimentally and new equipment for the disinfection of hands using this ozone foam has been put on the market for the practical use. The ozone foam was produced in the foam generator after mixing the water including surfactant (30 mL/min) and air including ozone (1000 ppm = 2.14 g/m3 ~ 1600 ppm = 3.4 g/m3, 300 mL/min). The liquid-to-gas ratio is 100 L/m3. The concentration of dissolved ozone in the thin liquid films of the bubbles was about 3 mg/L which was measured by the chemical method of the KI absorption and titration of sodium thiosulfate solution. The disinfection test samples were prepared using the PET disk on which Pseudomonas fluorescens of its number of more than 108 were attached. Test sample was inserted into ozone foam set on the glass plate for one to 6 min. The survival rate log (N/N0 decreased with time and its value of about-2.6 (i.e., ~1/400) was obtained at 6 min (2 min × 3 times repeated). It was also confirmed that the ozone foam was useful for the disinfection of hands. For more effective disinfection (in case of taking a long time for foam melting), the ozone foam was broken by force and changed into ozone water by which the survival rate decreased ×4 (i.e., N/N0 = 1/10 000) at 4 ~ 6 min. Contribution to the topical issue "The 14th International Symposium on High Pressure Low Temperature Plasma Chemistry (HAKONE XIV)", edited by Nicolas Gherardi, Ronny Brandenburg and Lars Stollenwark

  12. Learning from Balance Sheet Visualization

    Science.gov (United States)

    Tanlamai, Uthai; Soongswang, Oranuj

    2011-01-01

    This exploratory study examines alternative visuals and their effect on the level of learning of balance sheet users. Executive and regular classes of graduate students majoring in information technology in business were asked to evaluate the extent of acceptance and enhanced capability of these alternative visuals toward their learning…

  13. Off-Balance Sheet Financing.

    Science.gov (United States)

    Adams, Matthew C.

    1998-01-01

    Examines off-balance sheet financing, the facilities use of outsourcing for selected needs, as a means of saving operational costs and using facility assets efficiently. Examples of using outside sources for energy supply and food services, as well as partnering with business for facility expansion are provided. Concluding comments address tax…

  14. Inefficacy of marketed contact lens disinfection solutions against keratitis-causing Acanthamoeba castellanii belonging to the T4 genotype.

    Science.gov (United States)

    Lakhundi, Sahreena; Khan, Naveed Ahmed; Siddiqui, Ruqaiyyah

    2014-06-01

    The aim of this study was to assess the anti-amoebic effects of marketed contact lens disinfecting solutions. Using amoebistatic, amoebicidal, and cysticidal assays, nine different contact lens solutions were tested including: ReNu MultiPlus, DuraPlus, Ultimate Plus, OptiFree Replenish, OptiFree Express, Kontex Clean, Kontex Normal, Kontex Multisol extra+, Kontex Soak. In vitro growth inhibition (amoebistatic) assays were performed by incubating Acanthamoeba castellanii with aforementioned contact lens disinfection solutions as per manufacturer's instructions in the growth medium for up to 48h at 30°C. To determine amoebicidal and cysticidal effects, amoebae were incubated with contact lens solutions in phosphate buffered saline for 24h and viability was determined by haemocytometer counting as well as re-inoculating them in the growth medium. For controls, solutions were tested against bacterial corneal pathogen, Pseudomonas aeruginosa, as well as amoebae were incubated with the solvent alone. Of the nine contact lens solutions tested, none of them showed potent amoebicidal effects. Only DuraPlus and OptiFree Replenish exhibited trophozoite lysis of 85.3% and 73.7% respectively. In contrast, all contact lens disinfection solutions except Kontex Clean, Kontex Normal, Kontex Multisol extra+, tested showed amoebistatic effects. Importantly, none of the contact lens disinfection solutions exhibited cysticidal effects using qualitative assays, i.e., cysts treated with aforementioned solutions re-emerged as viable amoebae upon inoculation in the growth medium. However, more than 3-log reduction was observed when ReNu MultiPlus, DuraPlus and OptiFree Express were tested against P. aeruginosa which is in accordance with the ISO Stand-Alone Primary acceptance criteria. These findings are of great concern for contact lens users. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Effect of new disinfectant substances on pseudomonas aeruginosa

    International Nuclear Information System (INIS)

    Majtan, V.

    1998-01-01

    The anti-bacterial effect of 13 new commercially manufactured disinfectant substances on P. aeruginosa strain was studied. The substances tested represent 9 quaternary ammonium salts QAT and 4 combined QAT with other ingredients. The antimicrobial efficacy was characterised by influencing the growth and reproduction of bacterial cells expressed either by MIC and ED 50 as well as and ED 50 , as well as by the inhibition of incorporation rate of incorporation rate of [ 14 C] adenine and [ 14 C] leucine. The method of inhibition of [ 14 C] precursors is suitable as one from possible evaluation criterion on anti-bacterial efficacy of synthetic disinfectant substances. (authors)

  16. [Control of disinfection in the buildings of pig farms].

    Science.gov (United States)

    Maris, P

    1990-01-01

    A survey carried out in pig farms was undertaken in order to compare 4 disinfectants used in 13 disinfecting operations, during the vacation period. It was immediately noticeable that after swabbing and counting the staphylococci, the chloramine T-based preparation was more effective than the quaternary ammonium-aldehyde association, phenolic acid derivatives or the quaternary ammonium preparations. We then observed that although the number of organisms decreased by 99.8%, their number on slatted floors still ranged between 0.02 x 10(4) and 3 x 10(4) per cm2.

  17. Monitoring and improving the effectiveness of surface cleaning and disinfection.

    Science.gov (United States)

    Rutala, William A; Weber, David J

    2016-05-02

    Disinfection of noncritical environmental surfaces and equipment is an essential component of an infection prevention program. Noncritical environmental surfaces and noncritical medical equipment surfaces may become contaminated with infectious agents and may contribute to cross-transmission by acquisition of transient hand carriage by health care personnel. Disinfection should render surfaces and equipment free of pathogens in sufficient numbers to prevent human disease (ie, hygienically clean). Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  18. [Experiments on disinfection of vaccinia virus embedded in scabs and/or at the hand].

    Science.gov (United States)

    Schümann, K; Grossgebauer, K

    1977-01-01

    Vaccinia viruses embedded in rabbit dermal scabs were subjected to physical and chemical disinfection procedures. Scabs were suspended in vitro without saline or in physiological saline, and left for 1 hour at 70 to 90 degrees C. A complete inactivation was achived only in those scab samples which had been incubated at 90 degrees C for 1 hour and suspended in physiological saline. Scabs which had been placed in a disinfecting apparatus (Vacudes 4000) filled with mattrasses consistently proved to be free of infectious vaccinia viruses in each of the chosen programs. In addition scabs were subjected to disinfection by means of chemical disinfecting agents. The scabs had been placed in a chemical disinfecting suspension and left there for 90 minutes. Complete disinfection was obtained with glutaraldehyde 2%, formaldehyde 2%, Lysoformin 2% or 3%, phenol 5% and chloramine T 2%. Complete disinfection was likewise achieved after 3 hours treatment with some alchohols (ethylalcohol 80%, isopropylalcohol 7%, n-propylalcohol 60%), Amocid 5% and formaldehyde 1%.0.5% formaldehyde caused complete disinfection when applied for 6 hours. The only exception was a Quat which did not disinfect fully even after 18 hours application. Concerning the tests to disinfect the hands complete disinfection occurs when using chloramine T (1.5%) or isopropylalcohol (70%) in 2 to 5 minutes. Further tests were performed with scabs which were placed in sick rooms that were terminally disinfected with formaline vapor. It could be confirmed that the usual terminal disinfection with formaldehyde vapor was unable to completely disinfect the scabs. It is necessary to double the amount of formaldehyde (10 g formaldehyde per cubic metre of space) and prolong the period of treatment to 24 hours to achieve a greater degree of disinfection rate.

  19. Whooping Cough (Pertussis) - Fact Sheet for Parents

    Science.gov (United States)

    ... months 4 through 6 years Fact Sheet for Parents Color [2 pages] Español: Tosferina (pertussis) The best ... according to the recommended schedule. Fact Sheets for Parents Diseases and the Vaccines that Prevent Them Chickenpox ...

  20. Application of a high-level peracetic acid disinfection protocol to re-process antibiotic disinfected skin allografts.

    Science.gov (United States)

    Lomas, R J; Huang, Q; Pegg, D E; Kearney, J N

    2004-01-01

    Skin allografts, derived from cadaveric donors, are widely used for the treatment of burns and ulcers. Prior to use in clinical situations, these allografts are disinfected using a cocktail of antibiotics and then cryopreserved. Unfortunately, this antibiotic disinfection procedure fails to decontaminate a significant proportion and these contaminated grafts can not be used clinically. We have investigated whether it is possible to apply a second, more potent disinfection procedure to these contaminated grafts and effectively to re-process them for clinical use. Cadaveric skin grafts, treated with antibiotics and cryopreserved, were thawed and a peracetic acid (PAA) disinfection protocol applied. The grafts were then preserved in a high concentration of glycerol or propylene glycol, and properties thought to be essential for successful clinical performance assessed. The cytotoxicity of the grafts was assessed using both extract and contact assays; damage to the skin collagen was assessed using a collagenase susceptibility assay and the capacity of the grafts to elicit an inflammatory response in vitro was assessed by quantifying the production of the pro-inflammatory cytokine TNF-alpha by human peripheral blood mononuclear phagocytes. PAA disinfection, in conjunction with either glycerol or propylene glycol preservation, did not render the grafts cytotoxic, pro-inflammatory, or increase their susceptibility to collagenase digestion. The rates of penetration of glycerol and propylene glycol into the re-processed skin were comparable to those of fresh skin. This study has demonstrated that PAA disinfection combined with immersion in high concentrations of either glycerol or propylene glycol was an effective method for re-processing contaminated skin allografts, and may justify their clinical use.

  1. Sulfonated graphene oxide-ZnO-Ag photocatalyst for fast photodegradation and disinfection under visible light.

    Science.gov (United States)

    Gao, Peng; Ng, Kokseng; Sun, Darren Delai

    2013-11-15

    Synthesis of efficient visible-light-driven photocatalyst is urgent but challenging for environmental remediation. In this work, for the first time, the hierarchical plasmonic sulfonated graphene oxide-ZnO-Ag (SGO-ZnO-Ag) composites were prepared through nanocrystal-seed-directed hydrothermal method combining with polyol-reduction process. The results indicated that SGO-ZnO-Ag exhibited much faster rate in photodegradation of Rhodamine B (RhB) and disinfection of Escherichia coli (E. coli), than ZnO, SGO-ZnO and ZnO-Ag. SGO-ZnO-Ag totally degraded RhB dye and kill 99% of E. coli within 20 min under visible light irradiation. The outstanding performances of SGO-ZnO-Ag were attributed to the synergetic merits of SGO sheets, ZnO nanorod arrays and Ag nanoparticles. Firstly, the light absorption ability of SGO-ZnO-Ag composite in the visible region was enhanced due to the surface plasmon resonance of Ag. In addition, the hierarchical structure of SGO-ZnO-Ag composite improved the incident light scattering and reflection. Furthermore, SGO sheets facilitated charge transfer and reduce electron-hole recombination rate. Finally, the tentative mechanism was proposed and verified by the photoluminescence (PL) measurement as well as the theoretical finite-difference time-domain (FDTD) simulation. In view of above, this work paves the way for preparation of multi-component plasmonic composites and highlights the potential applications of SGO-ZnO-Ag in photocatalytic wastewater treatment field. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  2. Biobeam—Multiplexed wave-optical simulations of light-sheet microscopy

    Science.gov (United States)

    Weigert, Martin; Bundschuh, Sebastian T.

    2018-01-01

    Sample-induced image-degradation remains an intricate wave-optical problem in light-sheet microscopy. Here we present biobeam, an open-source software package that enables simulation of operational light-sheet microscopes by combining data from 105–106 multiplexed and GPU-accelerated point-spread-function calculations. The wave-optical nature of these simulations leads to the faithful reproduction of spatially varying aberrations, diffraction artifacts, geometric image distortions, adaptive optics, and emergent wave-optical phenomena, and renders image-formation in light-sheet microscopy computationally tractable. PMID:29652879

  3. 21 CFR 880.5180 - Burn sheet.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Burn sheet. 880.5180 Section 880.5180 Food and... Burn sheet. (a) Identification. A burn sheet is a device made of a porous material that is wrapped aroung a burn victim to retain body heat, to absorb wound exudate, and to serve as a barrier against...

  4. Manifold free multiple sheet superplastic forming

    Science.gov (United States)

    Elmer, John W.; Bridges, Robert L.

    2004-01-13

    Fluid-forming compositions in a container attached to enclosed adjacent sheets are heated to relatively high temperatures to generate fluids (gases) that effect inflation of the sheets. Fluid rates to the enclosed space between the sheets can be regulated by the canal from the container. Inflated articles can be produced by a continuous, rather than batch-type, process.

  5. On the possible eigenoscillations of neutral sheets

    International Nuclear Information System (INIS)

    Almeida, W.A.; Costa, J.M. da; Aruquipa, E.G.; Sudano, J.P.

    1974-12-01

    A neutral sheet model with hyperbolic tangent equilibrium magnetic field and hyperbolic square secant density profiles is considered. It is shown that the equation for small oscillations takes the form of an eigenvalue oscillation problem. Computed eigenfrequencies of the geomagnetic neutral sheet were found to be in the range of the resonant frequencies of the geomagnetic plasma sheet computed by other authors

  6. Diabetic Emergencies

    Science.gov (United States)

    ... Campaigns Share this! EmergencyCareForYou » Emergency 101 » Diabetic Emergencies Diabetic Emergencies It is estimated that more than 20 ... they have it. The best way to prevent diabetic emergencies is to effectively manage the disease through ...

  7. Disinfection ultraviolet radiation bulk food products

    OpenAIRE

    Семенов, А. А.

    2014-01-01

    В работе представлены результаты обеззараживания сыпучих пищевых продуктов ультрафиолетовым излучением. Предложена технология бактерицидного обеззараживания сыпучих продуктов с размером частиц до 50 мкм. Проведены необходимые расчеты, связанные с дозой облучения, с временем пребывания частиц в зоне облучения и необходимой дозой инактивации в зависимости от вида бактерий. Considered the results of bulk food products disinfection by ultraviolet radiation. The technology bactericidal disinfec...

  8. Catalog of CERCLA applicable or relevant and appropriate requirements (ARARs) - fact sheets

    Energy Technology Data Exchange (ETDEWEB)

    1990-07-01

    Section 121(d) of the Comprehensive Environmental Response Compensation and Liability Act (CERCLA) as amended by the Superfund Amendments and Reauthorization Act of 1986 (SARA), requires attainment of federal and state applicable or relevant and appropriate requirements (ARARs). Subpart E, Section 300.400(g) {open_quotes}Identification of applicable or relevant and appropriate requirements{close_quotes} of the National Oil and Hazardous Substances Pollution Contingency Plan (NCP)(55 FR 8666, March 8, 1990) describes the process for attaining ARARs. The purpose of this catalog is to provide DOE Program Offices and Field Organizations with all of the {open_quotes}Quick Reference Fact Sheets{close_quotes} on attaining ARARS. These fact sheets provide overviews of ARARs for CERCLA cleanup actions pertinent to DOE environmental restoration activities. All of the fact sheets in this catalog were prepared by the Environmental Protection Agency`s Office of Solid Waste and Emergency Response. Fact sheets 1-7 discuss land disposal restrictions (LDRs) and their applicability. LDRs may pertain to a number of CERCLA response actions at DOE facilities. Fact Sheets 8-13 are based on the CERCLA Compliance with Other Laws Manual: Parts I and II and provide an overview of many other CERCLA ARARs. Overview of ARARs-Focus on ARAR Waivers (fact sheet 11), provides a good introduction to ARARS. The last two fact sheets, 14 and 15, are periodic reports that describe additional fact sheets and clarify issues.

  9. Does disinfection of environmental surfaces influence nosocomial infection rates? A systematic review.

    Science.gov (United States)

    Dettenkofer, Markus; Wenzler, Sibylle; Amthor, Susanne; Antes, Gerd; Motschall, Edith; Daschner, Franz D

    2004-04-01

    To review the evidence on the effects of disinfection of environmental surfaces in hospitals (as compared with cleaning without use of disinfectants) on the occurrence of nosocomial infections. Systematic review of experimental and nonexperimental intervention studies dealing with environmental disinfection or cleaning in different health care settings. A total of 236 scientific articles were identified. None described a meta-analysis, systematic review, or randomized controlled trial. Only 4 articles described completed cohort studies matching the inclusion criteria. None of these studies showed lower infection rates associated with routine disinfection of surfaces (mainly floors) versus cleaning with detergent only. Disinfectants may pose a danger to staff, patients, and the environment and require special safety precautions. However, targeted disinfection of certain environmental surfaces is in certain instances an established component of hospital infection control. Given the complex, multifactorial nature of nosocomial infections, well-designed studies that systematically investigate the role of surface disinfection are required.

  10. One plunge or two?--hand disinfection with alcohol gel.

    Science.gov (United States)

    Macdonald, Duncan J M; Mckillop, Elisabeth C A; Trotter, Sylvia; Gray, Alastair J R

    2006-04-01

    To compare health care workers' hand surface coverage using two different volumes of alcohol gel for hand disinfection. and methods. A total of 84 members of staff in our hospital were studied. Subjects were asked to disinfect their hands with alcohol gel containing a clear fluorescent substance. Performance was assessed by using UV light to identify areas which had been missed, and the total surface area missed was calculated. A total of 42 subjects received 3.5 ml of alcohol gel, and 42 age-, sex-, and job-matched subjects received 1.75 ml of alcohol gel. Significantly less area was missed when hand disinfecting with double the volume of alcohol gel; 1.23 versus 6.35% surface area was missed (P disinfection significantly improves the efficiency of coverage of the hands with alcohol gel. This may result in lower bacterial count on the hands and may reduce the spread of nosocomial infections including that of methicillin-resistant Staphylococcus aureus.

  11. Surface dielectric barrier discharge jet for skin disinfection

    NARCIS (Netherlands)

    Creyghton, Y.; Meijer, R.; Verweij, P.; Zanden, F. van der; Leenders, P.

    2012-01-01

    A consortium consisting of the research institute TNO, the medical -university and hospital St Radboud and two industrial enterprises is working on a non-thermal plasma treatment method for hand disinfection. The group is seeking for cooperation, in particular in the field of validation methods and

  12. Control of house-dust mites with home disinfectants

    NARCIS (Netherlands)

    Schober, G.; Wetter, G.; Bischoff, E.; Bronswijk, van J.E.M.H.; Kniest, F.M.

    1987-01-01

    Chemical disinfectants and biocidal preparations used in households were tested in the laboratory for their ability to kill the house-dust miteDermatophagoides farinae. Batches of ten specimens were soaked in aqueous solutions or suspensions containing 0.0, 0.1, 0.3, 1.0, 3.0 and 10.0% (by volume)

  13. 9 CFR 53.6 - Disinfection of animals.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Disinfection of animals. 53.6 Section 53.6 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF... of animals. Animals of species not susceptible to the disease for which a quarantine has been...

  14. A parametrical study of disinfection with hydrodynamic cavitation.

    Science.gov (United States)

    Arrojo, S; Benito, Y; Tarifa, A Martínez

    2008-07-01

    The physical and chemical conditions generated by cavitation bubbles can be used to destroy microorganisms and disinfect wastewater. The effect of different cavitation chamber designs and diverse operational parameters on the inactivation rate of Escherichia coli have been studied and used to understand the mechanisms involved in cell disruption.

  15. Disinfection Alternatives for Small Communities in Puerto Rico

    Science.gov (United States)

    Disinfection Alternatives for Small Communities in Puerto Rico Craig Patterson1, Graciela Ramirez Toro2, Harvey Minnigh2, Cristina Maldonado3, and Rajib Sinha4 1U.S. EPA Office of Research and Development, 2Centro de Educación, Conservación e Interpretación Ambiental (CECIA),...

  16. A biocoagulant slow sand filtration for disinfection of Toxoplasma ...

    African Journals Online (AJOL)

    An integrated low-tech biocoagulant-sand filter drum for disinfection of oocysts of Toxoplasma gondii targeted for developing countries was evaluated. Dirty and turbid water (130.3 NTU) from Mezam River and leachates from dump sites and stagnant water in Bamenda, Cameroon, was analyzed microscopically after ...

  17. Assessment of peracetic acid disinfected effluents by microbiotests.

    Science.gov (United States)

    Antonelli, M; Mezzanotte, V; Panouillères, M

    2009-09-01

    Bioassays were performed by commercially available kits on peracetic acid (PAA) solutions, at different concentrations, and on secondary effluents (from two different wastewater treatment plants) after disinfection at bench-scale, considering both samples containing residual active PAA and the same samples where residual PAA was quenched. Four indicator organisms were used: Vibrio fischeri, Thamnocephalus platyurus, Daphnia magna, and Selenastrum capricornutum. The experiments lead to conclude that Thamnocephalus platyurus is a very sensitive organism, probably not adequate to perform a reliable toxicity assessment of effluents for monitoring purposes. The presence of specific organic compounds deriving from human metabolism and urban pollution, even at very low concentrations, can affect the results of bioassays, especially those performed on Vibrio fischeri. PAA is toxic for bacteria and crustaceans even at concentrations lower than the ones commonly used in wastewater disinfection (2-5 mg/L), while its effect on algae is smaller. The toxic effect on bacteria was expected, as PAA is used for disinfection, but its possible influence on biological processes in the receiving aquatic environment should be considered. Toxicity on crustaceans would confirm the fact that discharging disinfected effluents could raise some environmental problems.

  18. Wastewater disinfection alternatives: chlorine, ozone, peracetic acid, and UV light.

    Science.gov (United States)

    Mezzanotte, V; Antonelli, M; Citterio, S; Nurizzo, C

    2007-11-01

    Disinfection tests were carried out at pilot scale to compare the disinfection efficiency of ozone, sodium hypochlorite (NaOCl), peracetic acid (PAA), and UV irradiation. Total coliforms, fecal coliforms, and Escherichia coli were monitored as reference microorganisms. Total heterotrophic bacteria (THB) were also enumerated by cytometry. At similar doses, NaOCl was more effective than PAA, and its action was less affected by contact time. The results obtained by ozonation were comparable for total coliforms, fecal coliforms, and E. coli. On the contrary, some differences among the three indicators were observed for NaOCl, PAA, and UV. Differences increased with increasing values of the disinfectant concentration times contact time (C x t) and were probably the result of different initial counts, as total coliforms include fecal coliforms, which include E. coli. The UV irradiation lead to complete E. coli removals, even at low doses (10 to 20 mJ/cm2). Total heterotrophic bacteria appeared to be too wide a group to be a good disinfection indicator; no correlation was found among THB inactivation, dose, and contact time.

  19. 7 CFR 301.89-12 - Cleaning, disinfection, and disposal.

    Science.gov (United States)

    2010-01-01

    ... indica must be cleaned and disinfected in accordance with § 301.89-13 prior to being used in the conditioning of seed that has tested negative for the spores of Tilletia indica or to being moved from a... move bunted-kernel-positive host crops, including trucks, railroad cars, and other containers, that...

  20. A prototype catheter designed for ultraviolet C disinfection

    DEFF Research Database (Denmark)

    Bak, Jimmy; Begovic, Tanja

    2013-01-01

    UVC light exposure, sampling and plate counting. Findings Two minutes of UVC exposure was sufficient to obtain 4 log10 disinfection for the full-length prototype catheter. This exposure corresponds to ∼40 mJ/cm2 at the catheter tip and indicates that even shorter exposure times can be achieved...

  1. The Effect of Various Brands of Chloroxylenol disinfectants on Some ...

    African Journals Online (AJOL)

    Suspension and surface viability tests were carried out to determine the effects of various brands of chloroxylenol disinfectants on clinically important nosocomial gram negative and gram-positive organisms. Dettol and morigard brands of chloroxylenol inhibited gram-positive organisms at a dilution of 1 in 50. Tiscol brand of ...

  2. UASB reactor effluent disinfection by ozone and chlorine

    NARCIS (Netherlands)

    Ribeiro da Silvia, G.H.; Bruning, H.; Gerrity, D.; Daniel, L.A.

    2015-01-01

    This research studied the sequential ozone and chlorine process with respect to, the inactivation of indicator bacteria and the formation of ozone disinfection byproducts in sanitary wastewater effluent. The applied ozone doses were 5, 8 and 10 mg.O3.L-1, followed by chlorine doses of 10, 20 and 30

  3. A practical evaluation of detergent and disinfectant solutions on ...

    African Journals Online (AJOL)

    Student01

    2012-01-06

    Jan 6, 2012 ... inactivation efficacy and effect on material corrosion ... Cleaning and disinfection agents were evaluated against selected bacteria on ... bacteria strains: Escherichia coli K12, E. coli DSM 682, Salmonella ... in terms of the lifespan of the equipment, and also ..... Individual descriptions of the observed basis.

  4. The effect of various disinfectants on dental shade guides.

    Science.gov (United States)

    Huang, Peterson Y; Masri, Radi; Romberg, Elaine; Driscoll, Carl F

    2014-09-01

    Dental shade guides are used to evaluate tooth color before prosthodontic procedures and are subjected to disinfection after use. The effect of disinfection on shade guides has not been thoroughly investigated. The purpose of this study was to evaluate the effect of disinfectants on the color of shade tabs. Changes in the color (ΔE) of VITA Classical Shade Guide tabs were measured with a VITA Easyshade spectrophotometer in the CIELAB system and calculated after being subjected to Cavicide, Asepticare TB, Sporicidin, and distilled water (control) over a simulated period of 2 years. Statistical analysis was accomplished by a 2-way analysis of variance followed by the Tukey honestly significant difference (HSD) test (α=.05). A significant difference was noted in the degree of shade tab color change, depending on the type of disinfectant used (F=153.2, PCavicide (ΔE=1.198). The average total CIELAB color difference for 50% human perceptibility is approximately 1 unit (under standardized laboratory conditions). In the oral cavity, however, an average change of 3.7 ΔE units could still allow teeth to be perceived as having the same color. Therefore, although the results are statistically significant, they may not be clinically important. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  5. [The effect of disinfectant soaking on dental gypsum model size].

    Science.gov (United States)

    Zhu, Cao-yun; Xu, Yun-wen; Xu, Kan

    2012-12-01

    To study the influence of disinfectant soaking on the dimensional stability of three kinds of dental gypsum model. Three commonly used gypsums ( type III,IV,Vtype) in clinic were used to make 24 specimens for 50 mm×15 mm×10 mm in size. One hour after release, the specimens were placed for 24 h. A digital caliper was used to measure the size of the gypsum model. Distilled water immersion was as used control, glutaraldehyde disinfectant and Metrix CaviCide disinfectant soaking were used for the experimental group. After soaking for 0.5h, the gypsum models were removed and placed for 0.5 h, 1 h, 2 h, 24 h. The size of the models was measured again using the same method. The data was analyzed with SPSS10.0 software package. The initial gypsum model length was (50.07±0.017) mm, (50.048±0.015) mm and (50.027±0.015) mm. After soaking for different times, the size of the model changed little, and the dimensions changed less than 0.01%. The results show that disinfectant soaking has no significant effect on dental model dimensions.

  6. Effects of Ozone and Photo‑Activated Disinfection against ...

    African Journals Online (AJOL)

    Objectives: The purpose of this study was to compare the antibacterial effects of gaseous ozone (O3) and photo‑activated disinfection (PAD) methods against Enterococcus faecalis (E. faecalis) biofilms. Materials and Methods: Sixty‑five human mandibular premolars with straight root canals were selected. After root canal ...

  7. Moist Heat Disinfection and Revisiting the A0 Concept.

    Science.gov (United States)

    McCormick, Patrick J; Schoene, Michael J; Dehmler, Matthew A; McDonnell, Gerald

    2016-04-02

    Moist heat is employed in the medical device, pharmaceutical, and food processing industries to render products and goods safe for use and human consumption. Applications include its use to pasteurize a broad range of foods and beverages, the control of microbial contamination of blood products, and treatment of bone tissue transplants and vaccines. In the pharmaceutical industry, water heated to 65°C to 80°C is used to sanitize high-purity water systems. In healthcare, it has been employed for decades to disinfect patient care items ranging from bedpans to anesthesia equipment. There is a good understanding of the conditions necessary to achieve disinfection of microorganisms at temperatures ranging from 65°C to 100°C. Based on this information, the efficacy of moist heat processes at a range of exposure times and temperatures can be quantified based on mathematical models such as the A0 calculation. While the A0 concept is recognized within the European healthcare community, it has yet to be widely adopted within the United States. This article provides information regarding the A0 concept, a brief overview of the classification of thermal disinfection for use with healthcare applications within the United States, and recent data on reinvestigating the thermal disinfection of a selected panel of microorganisms and a mixed culture biofilm.

  8. Disinfection of wastewater with peracetic acid: a review.

    Science.gov (United States)

    Kitis, Mehmet

    2004-03-01

    Peracetic acid is a strong disinfectant with a wide spectrum of antimicrobial activity. Due to its bactericidal, virucidal, fungicidal, and sporicidal effectiveness as demonstrated in various industries, the use of peracetic acid as a disinfectant for wastewater effluents has been drawing more attention in recent years. The desirable attributes of peracetic acid for wastewater disinfection are the ease of implementing treatment (without the need for expensive capital investment), broad spectrum of activity even in the presence of heterogeneous organic matter, absence of persistent toxic or mutagenic residuals or by-products, no quenching requirement (i.e., no dechlorination), small dependence on pH, short contact time, and effectiveness for primary and secondary effluents. Major disadvantages associated with peracetic acid disinfection are the increases of organic content in the effluent due to acetic acid (AA) and thus in the potential microbial regrowth (acetic acid is already present in the mixture and is also formed after peracetic acid decomposition). Another drawback to the use of peracetic acid is its high cost, which is partly due to limited production capacity worldwide. However, if the demand for peracetic acid increases, especially from the wastewater industry, the future mass production capacity might also be increased, thus lowering the cost. In such a case, in addition to having environmental advantages, peracetic acid may also become cost-competitive with chlorine.

  9. The Forming of AISI 409 sheets for fan blade manufacturing

    International Nuclear Information System (INIS)

    Foroni, F. D.; Menezes, M. A.; Moreira Filho, L. A.

    2007-01-01

    The necessity of adapting the standardized fan models to conditions of higher temperature has emerged due to the growth of concern referring to the consequences of the gas expelling after the Mont Blanc tunnel accident in Italy and France, where even though, with 100 fans in operation, 41 people died. The objective of this work is to present an alternative to the market standard fans considering a new technology in constructing blades. This new technology introduces the use of the stainless steel AISI 409 due to its good to temperatures of gas exhaust from tunnels in fire situation. The innovation is centered in the process of a deep drawing of metallic sheets in order to keep the ideal aerodynamic superficies for the fan ideal performance. Through the impression of circles on the sheet plane it is shown, experimentally, that, during the pressing process, the more deformed regions on the sheet plane of the blade can not reach the deformation limits of the utilized sheet material

  10. Geometry of thin liquid sheet flows

    Science.gov (United States)

    Chubb, Donald L.; Calfo, Frederick D.; Mcconley, Marc W.; Mcmaster, Matthew S.; Afjeh, Abdollah A.

    1994-01-01

    Incompresible, thin sheet flows have been of research interest for many years. Those studies were mainly concerned with the stability of the flow in a surrounding gas. Squire was the first to carry out a linear, invicid stability analysis of sheet flow in air and compare the results with experiment. Dombrowski and Fraser did an experimental study of the disintegration of sheet flows using several viscous liquids. They also detected the formulation of holes in their sheet flows. Hagerty and Shea carried out an inviscid stability analysis and calculated growth rates with experimental values. They compared their calculated growth rates with experimental values. Taylor studied extensively the stability of thin liquid sheets both theoretically and experimentally. He showed that thin sheets in a vacuum are stable. Brown experimentally investigated thin liquid sheet flows as a method of application of thin films. Clark and Dumbrowski carried out second-order stability analysis for invicid sheet flows. Lin introduced viscosity into the linear stability analysis of thin sheet flows in a vacuum. Mansour and Chigier conducted an experimental study of the breakup of a sheet flow surrounded by high-speed air. Lin et al. did a linear stability analysis that included viscosity and a surrounding gas. Rangel and Sirignano carried out both a linear and nonlinear invisid stability analysis that applies for any density ratio between the sheet liquid and the surrounding gas. Now there is renewed interest in sheet flows because of their possible application as low mass radiating surfaces. The objective of this study is to investigate the fluid dynamics of sheet flows that are of interest for a space radiator system. Analytical expressions that govern the sheet geometry are compared with experimental results. Since a space radiator will operate in a vacuum, the analysis does not include any drag force on the sheet flow.

  11. Periodic folding of viscous sheets

    Science.gov (United States)

    Ribe, Neil M.

    2003-09-01

    The periodic folding of a sheet of viscous fluid falling upon a rigid surface is a common fluid mechanical instability that occurs in contexts ranging from food processing to geophysics. Asymptotic thin-layer equations for the combined stretching-bending deformation of a two-dimensional sheet are solved numerically to determine the folding frequency as a function of the sheet’s initial thickness, the pouring speed, the height of fall, and the fluid properties. As the buoyancy increases, the system bifurcates from “forced” folding driven kinematically by fluid extrusion to “free” folding in which viscous resistance to bending is balanced by buoyancy. The systematics of the numerically predicted folding frequency are in good agreement with laboratory experiments.

  12. [The principle of registration, evaluation and testing of disinfecting preparations].

    Science.gov (United States)

    Röhm-Rodowald, Ewa; Jakimiak, Bozenna; Podgórska, Marta

    2008-01-01

    Disinfectants are used to produce a state in which the number of living micro-organisms has been reduced to a level which is appropriate to the practical situation. For any products which are included in the Biocidal Directive 98/8/EC, for which specific activity is claimed, test data has to be approved by the regulatory authority and a product license obtained before the product can be offered for sale. Disinfectants can be recorded as biocidal products or medical devices. Presently, it is possible to measure the activity of a product on defined micro-organisms in specified experimental conditions. Efficacy is the result of the use of a product according to a defined application. To allow different requirements in different areas of application, separate tests and pass criteria have been or will be prepared for each of following three areas of application: medical, veterinary and group comprising food, industrial, domestic and institutional areas. The laboratory methods to be used for testing the activity of chemical disinfectants meets the European standards. The tests are categorised on a modular basis as follows: phase 1 tests, phase 2 step 1 tests, phase 2 step 2 tests and phase 3 tests. In order to claim that a product has disinfectant properties, suitable for use in the medical area, the product shall be tested according to European standards: phase 2 step 1 tests, phase 2 step 2 tests. Phase 1 tests are not required to support claims for chemical disinfectants used in human medicine. Only phase 1 tests are required to support claims for active substances for which no particular area of application is specified. Medical devices are subjects to the European Directive 93/42/EEC which requires that a product must carry a CE mark. Disinfectants which are intended specifically by its manufacturer to be used on medical devices are themselves medical devices and so these products, as well as conforming to the instrument disinfection European standards as specified

  13. Load Test in Sheet Pile

    OpenAIRE

    Luis Orlando Ibanez

    2016-01-01

    In this work, are discussed experiences in the use of mathematical modeling and testing in hydraulic engineering structures. For this purpose the results of load tests in sheet pile, evaluating horizontal and vertical deformations that occur in the same exposed. Comparisons between theoretical methods for calculating deformations and mathematical models based on the Finite Element Method are established. Finally, the coincidence between the numerical model and the results of the load test ful...

  14. Ohm's law for a current sheet

    Science.gov (United States)

    Lyons, L. R.; Speiser, T. W.

    1985-01-01

    The paper derives an Ohm's law for single-particle motion in a current sheet, where the magnetic field reverses in direction across the sheet. The result is considerably different from the resistive Ohm's law often used in MHD studies of the geomagnetic tail. Single-particle analysis is extended to obtain a self-consistency relation for a current sheet which agrees with previous results. The results are applicable to the concept of reconnection in that the electric field parallel to the current is obtained for a one-dimensional current sheet with constant normal magnetic field. Dissipated energy goes directly into accelerating particles within the current sheet.

  15. Collective epithelial cell sheet adhesion and migration on polyelectrolyte multilayers with uniform and gradients of compliance

    International Nuclear Information System (INIS)

    Martinez, Jessica S.; Schlenoff, Joseph B.; Keller, Thomas C.S.

    2016-01-01

    surfaces. Interestingly, cells throughout the interior region of the sheets on uncrosslinked PEMUs retained their actin and vinculin organization at adherens junctions after treatment with Blebbistatin. Like Blebbistatin, a Rho-kinase (ROCK) inhibitor, Y27632, promoted loss of cell-cell connections between edge cells, whereas a Rac1 inhibitor, NSC23766, primarily altered the lamellipodial protrusion in edge cells. Compliance gradient PAH-PEMUs promoted durotaxis of the cell sheets but not of individual keratocytes, demonstrating durotaxis, like plithotaxis, is an emergent property of cell sheet organization. - Highlights: • Fish scale cell sheets migrate on PAH-PAABp polyelectrolyte multilayers. • Sheets migrating on softer PEMUs periodically retract. • Sheets durotax on modulus gradients. • Myosin II inhibitors inhibit sheet integrity and migration.

  16. Collective epithelial cell sheet adhesion and migration on polyelectrolyte multilayers with uniform and gradients of compliance

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, Jessica S. [Department of Biological Science, Florida State University, Tallahassee, FL 32306 (United States); Schlenoff, Joseph B. [Department of Chemistry and Biochemistry, Florida State University, Tallahassee, FL 32306 (United States); Keller, Thomas C.S., E-mail: tkeller@bio.fsu.edu [Department of Biological Science, Florida State University, Tallahassee, FL 32306 (United States)

    2016-08-01

    surfaces. Interestingly, cells throughout the interior region of the sheets on uncrosslinked PEMUs retained their actin and vinculin organization at adherens junctions after treatment with Blebbistatin. Like Blebbistatin, a Rho-kinase (ROCK) inhibitor, Y27632, promoted loss of cell-cell connections between edge cells, whereas a Rac1 inhibitor, NSC23766, primarily altered the lamellipodial protrusion in edge cells. Compliance gradient PAH-PEMUs promoted durotaxis of the cell sheets but not of individual keratocytes, demonstrating durotaxis, like plithotaxis, is an emergent property of cell sheet organization. - Highlights: • Fish scale cell sheets migrate on PAH-PAABp polyelectrolyte multilayers. • Sheets migrating on softer PEMUs periodically retract. • Sheets durotax on modulus gradients. • Myosin II inhibitors inhibit sheet integrity and migration.

  17. Disinfecting the iPad: evaluating effective methods.

    Science.gov (United States)

    Howell, V; Thoppil, A; Mariyaselvam, M; Jones, R; Young, H; Sharma, S; Blunt, M; Young, P

    2014-06-01

    Tablet computers are increasingly used in healthcare, but they may carry nosocomial pathogens. There are few data available on how to clean an iPad effectively for use in the clinical setting. We aimed to identify the most effective method of decontaminating the Apple iPad, without causing damage, and establish the duration of any residual effect. Following contamination with a microbial broth (meticillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant enterococcus (VRE) and Clostridium difficile), we examined efficacy of iPad disinfection in the laboratory using six different disinfectant wipes: Sani-Cloth CHG 2% (chlorhexidine 2%/alcohol 70%), Clorox, Tristel, Trigene, soap and water, and plain cloth. Following cleaning, iPads were recontaminated to examine residual activity. After 480 Sani-Cloth CHG 2% disinfecting episodes, functional and visual analysis of iPads was performed by blinded subjects. With the exception of Clostridium difficile, Sani-Cloth CHG 2% and Clorox wipes were most effective against MRSA and VRE, and they were significantly better than the Apple-recommended plain cloth (P ≤ 0.001). A substantial residual antimicrobial effect was seen for >6h after wiping the iPad with Sani-Cloth CHG 2% despite repeated recontamination and without further disinfection. The functionality or visual appearance of the iPad was not damaged by repeated use of Sani-Cloth CHG 2% wipes. Sani-Cloth CHG 2% wipes effectively disinfect the iPad against MRSA and VRE, with a residual antibacterial effect and without causing damage. Copyright © 2014 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  18. Dimensional Stability of Color-Changing Irreversible Hydrocolloids after Disinfection

    Directory of Open Access Journals (Sweden)

    Khaledi AAR

    2015-03-01

    Full Text Available Statement of Problem: Disinfection of dental impressions is a weak point in the dental hygiene chain. In addition, dental office personnel and dental technicians are endangered by cross-contamination. Objectives: This study aimed to investigate the dimensional stability of two color-changing irreversible hydrocolloid materials (IH after disinfection with glutaraldehyde. Materials and Methods: In this in vitro study, impressions were made of a master maxillary arch containing three reference inserts on the occlucal surface of the left and right maxillary second molars and in the incisal surface of the maxillary central incisors. Two types of color-changing irreversible hydrocolloid (tetrachrom, cavex were used. Glutaraldehyde 2% was used in two methods of spraying and immersion to disinfect the impressions. The control group was not disinfected. Casts were made of type IV gypsum. The linear dimensional change of the stone casts was measured with a profile projector. For statistical analysis, Kruskall-Wallis and Mann-Witney tests were used (α=0.05. Results: By immersion method, the casts fabricated from tetrachrom were 0.36% larger in the anteroposterior (AP and 0.05% smaller in cross arch (CA dimensions; however, the casts prepared after spraying of tetrachrom were 0.44% larger in the AP and 0.10% smaller in CA dimensions. The casts made from Cavex were 0.05% smaller in the AP and 0.02% smaller in CA dimensions after spraying and 0.01% smaller in the AP and 0.003% smaller in CA dimensions after immersion. Generally there were not significant differences in AP and CA dimensions of the experimental groups compared to the control (p > 0.05. Conclusions: Disinfection of the tested color-changing irreversible hydrocolloids by glutaraldahyde 2% did not compromise the accuracy of the obtained casts.

  19. The Potsdam Parallel Ice Sheet Model (PISM-PIK – Part 2: Dynamic equilibrium simulation of the Antarctic ice sheet

    Directory of Open Access Journals (Sweden)

    M. A. Martin

    2011-09-01

    Full Text Available We present a dynamic equilibrium simulation of the ice sheet-shelf system on Antarctica with the Potsdam Parallel Ice Sheet Model (PISM-PIK. The simulation is initialized with present-day conditions for bed topography and ice thickness and then run to steady state with constant present-day surface mass balance. Surface temperature and sub-shelf basal melt distribution are parameterized. Grounding lines and calving fronts are free to evolve, and their modeled equilibrium state is compared to observational data. A physically-motivated calving law based on horizontal spreading rates allows for realistic calving fronts for various types of shelves. Steady-state dynamics including surface velocity and ice flux are analyzed for whole Antarctica and the Ronne-Filchner and Ross ice shelf areas in particular. The results show that the different flow regimes in sheet and shelves, and the transition zone between them, are captured reasonably well, supporting the approach of superposition of SIA and SSA for the representation of fast motion of grounded ice. This approach also leads to a natural emergence of sliding-dominated flow in stream-like features in this new 3-D marine ice sheet model.

  20. The Potsdam Parallel Ice Sheet Model (PISM-PIK) - Part 2: Dynamic equilibrium simulation of the Antarctic ice sheet

    Science.gov (United States)

    Martin, M. A.; Winkelmann, R.; Haseloff, M.; Albrecht, T.; Bueler, E.; Khroulev, C.; Levermann, A.

    2011-09-01

    We present a dynamic equilibrium simulation of the ice sheet-shelf system on Antarctica with the Potsdam Parallel Ice Sheet Model (PISM-PIK). The simulation is initialized with present-day conditions for bed topography and ice thickness and then run to steady state with constant present-day surface mass balance. Surface temperature and sub-shelf basal melt distribution are parameterized. Grounding lines and calving fronts are free to evolve, and their modeled equilibrium state is compared to observational data. A physically-motivated calving law based on horizontal spreading rates allows for realistic calving fronts for various types of shelves. Steady-state dynamics including surface velocity and ice flux are analyzed for whole Antarctica and the Ronne-Filchner and Ross ice shelf areas in particular. The results show that the different flow regimes in sheet and shelves, and the transition zone between them, are captured reasonably well, supporting the approach of superposition of SIA and SSA for the representation of fast motion of grounded ice. This approach also leads to a natural emergence of sliding-dominated flow in stream-like features in this new 3-D marine ice sheet model.

  1. Experimental formability analysis of bondal sandwich sheet

    Science.gov (United States)

    Kami, Abdolvahed; Banabic, Dorel

    2018-05-01

    Metal/polymer/metal sandwich sheets have recently attracted the interests of industries like automotive industry. These sandwich sheets have superior properties over single-layer metallic sheets including good sound and vibration damping and light weight. However, the formability of these sandwich sheets should be enhanced which requires more research. In this paper, the formability of Bondal sheet (DC06/viscoelastic polymer/DC06 sandwich sheet) was studied through different types of experiments. The mechanical properties of Bondal were determined by uniaxial tensile tests. Hemispherical punch stretching and hydraulic bulge tests were carried out to determine the forming limit diagram (FLD) of Bondal. Furthermore, cylindrical and square cup drawing tests were performed in dry and oil lubricated conditions. These tests were conducted at different blank holding forces (BHFs). An interesting observation about Bondal sheet deep drawing was obtaining of higher drawing depths at dry condition in comparison with oil-lubricated condition.

  2. Buckling and stretching of thin viscous sheets

    Science.gov (United States)

    O'Kiely, Doireann; Breward, Chris; Griffiths, Ian; Howell, Peter; Lange, Ulrich

    2016-11-01

    Thin glass sheets are used in smartphone, battery and semiconductor technology, and may be manufactured by producing a relatively thick glass slab and subsequently redrawing it to a required thickness. The resulting sheets commonly possess undesired centerline ripples and thick edges. We present a mathematical model in which a viscous sheet undergoes redraw in the direction of gravity, and show that, in a sufficiently strong gravitational field, buckling is driven by compression in a region near the bottom of the sheet, and limited by viscous resistance to stretching of the sheet. We use asymptotic analysis in the thin-sheet, low-Reynolds-number limit to determine the centerline profile and growth rate of such a viscous sheet.

  3. Disinfection aboard cruise liners and naval units: formation of disinfection by-products using chlorine dioxide in different qualities of drinking water.

    Science.gov (United States)

    Ufermann, Petra; Petersen, Hauke; Exner, Martin

    2011-12-01

    The world-wide deployment of cruise liners and naval units has caused an increased need for the disinfection of drinking water. The main cause for this is the unknown quality of drinking water in foreign harbours--besides the formation of bio-films due to the climatically disadvantageous conditions in the operational area. Water conduits on board are currently disinfected with calcium hypochlorite in case of microbiological contamination. Chemical and physical analyses after disinfection with calcium hypochlorite have shown that organic by-products consisting of trihalomethanes develop in considerable amounts during disinfection. Furthermore, the method is susceptible to handling errors and thus often leads to insufficient disinfection results. Hitherto, the use of other disinfection methods allowed by government regulations, especially chlorine dioxide, is not widely spread. Unlike disinfection with calcium hypochlorite, chlorine dioxide does not lead to the formation of trihalomethanes. Typical disinfection by-products (DBP) are the anions chlorite and chlorate, which are formed in oxidative processes. The formation conditions of these anions have not yet been elucidated. For this reason, the probability of the generation of inorganic by-products after disinfection with chlorine dioxide has been determined, and their occurrence in drinking water on board has been examined with respect to a possible correlation between water quality and the formation of chlorate and chlorite. Therefore, a chromatographic method was developed and validated in order to determine the periodical development of chlorate and chlorite from chorine dioxide in purified water at different pH-values as well as in actual drinking water samples from water conduits on board. The formation of the by-products chlorite and chlorate after disinfection with chlorine dioxide is influenced neither by pH-value nor by chemical properties of the disinfected water. Considering the examined conditions

  4. Emergency Communication

    Science.gov (United States)

    : Environmental Documents, Reports LANL Home Calendar Search Contacts Resources » Emergency Communication Emergency Communication Stay informed of emergencies, weather delays, closures, other alerts. Find links to

  5. The Effect of Disinfection by Spray Atomization on Dimensional Accuracy of Condensation Silicone Impressions

    Directory of Open Access Journals (Sweden)

    Fariba Saleh Saber

    2010-12-01

    Full Text Available Background and aims. The condensation silicone impression materials are available, but there is little knowledge of their accuracy after disinfection. The objective of this study was to evaluate the effect of the disinfection by spray atomization on dimensional accuracy of condensation silicone impressions. Materials and methods. Impressions were made on a stainless steel master model containing a simulated two complete crown preparation with an edentulous space interposed using Spidex® and Rapid® impression materials. 44 impressions were made with each material, of which 16 were disinfected with 5.25% sodium hypochlorite, 16 were disinfected with 10% iodophor and 12 were not disinfected. Three dimensional measurements of working casts, including interpreparation distance, height, and diameter, were calculated using a measuring microscope graduated at 0.001 mm. Dimensional changes (mm between the disinfected and non-disinfected working casts were compared. One-way analysis of variance (ANOVA was employed to analyze the data (α=0.05. Results. Disinfection of each condensation silicone material by spraying atomization with two different disinfectant material resulted in significant change in interpreparation distance (p<0.05. Changes in height and diameter were only significant in Spidex® impressions (p<0.05. Conclusion. Significant changes in the mean dimensions were seen as a result of disinfection by spraying; however, the dimensional changes do not seem great enough to cause critical positional distortion of teeth when fixed partial denture restorations are made.

  6. Resistance to disinfection of a polymicrobial association contaminating the surface of elastomeric dental impressions.

    Science.gov (United States)

    Giammanco, Giovanni M; Melilli, Dario; Rallo, Antonio; Pecorella, Sonia; Mammina, Caterina; Pizzo, Giuseppe

    2009-04-01

    The aim of this study was to evaluate the ability to resist disinfection of a polymicrobial association contaminating the surface of dental impressions obtained with two different elastomers: a polyether (Impregum) and an addition-polymerized silicone (Elite). Impressions were contaminated with a mixture of three biofilm-forming microorganisms (Staphylococcus aureus, Pseudomonas aeruginosa and Candida albicans) and disinfected immediately after contamination, or after microbial layers were allowed to develop during a six-hour storage. Two commercial disinfectants were tested: MD 520 containing 0.5% glutaraldehyde and Sterigum Powder without glutaraldehyde. Residual contamination was recovered by mechanical rinsing immediately after disinfection and after a six-hour storage of disinfected impressions, and assessed by colony counting. Both disinfectants tested were shown to be effective in reducing the microbial presence on the impression materials, achieving at least a 102 reduction of microbial counts compared to water rinsing. However, Sterigum was generally less effective on the Elite elastomer and could not grant disinfection on six-hour aged P. aeruginosa and C. albicans microbial layers. The results of this study suggest that the materials used for the impressions influence the efficacy of disinfection. Disinfectants should be tested according to conditions encountered in everyday clinical practice and the need for immediate disinfection of impressions should be clearly indicated by manufacturers.

  7. In-Use Evaluation of Peracetic Acid for High-Level Disinfection of Endoscopes.

    Science.gov (United States)

    Chenjiao, Wu; Hongyan, Zhang; Qing, Gu; Xiaoqi, Zhong; Liying, Gu; Ying, Fang

    2016-01-01

    Many high-level disinfectants have been used for disinfection of endoscopes such as 2% glutaraldehyde (GA), 0.55% ortho-phthalaldehyde (OPA), and peracetic acid (PAA). Both GA and OPA are widely used in disinfection of endoscopes and have been previously discussed, but there is little research on the practical use of PAA as an endoscope disinfectant. An experimental model of a flexible gastrointestinal endoscope being contaminated with 9 strains of microorganism was designed. After the cleaning and disinfecting procedure was completed, we evaluated the biocidal activity (850 ppm PAA, 2% GA, and 0.55% OPA) on our flexible gastrointestinal endoscope model. We also evaluated sterilization effectiveness of PAA on other bacteria, including some antibiotic-resistant bacteria (methicillin-resistant Staphylococcus aureus, vancomycin-resistant Enterococcus, and Clostridium difficile). The residual bacterial colony count number of the PAA-disinfected endoscope was significantly lower than that of the GA- and OPA-disinfected endoscopes. The biocidal effect and efficiency of the endoscope disinfection by PAA appeared to be better than either the GA- or OPA-disinfected endoscope. PAA has demonstrated a good sterilization effect on other bacterial species; of particular note are common antibiotic-resistant bacteria such as methicillin-resistant Staphylococcus aureus, vancomycin-resistant Enterococcus, and Clostridium difficile. The results of this study demonstrate that PAA is a fast and effective high-level disinfectant for use in the reprocessing of flexible endoscopes.

  8. Toxic impact of bromide and iodide on drinking water disinfected with chlorine or chloramines.

    Science.gov (United States)

    Yang, Yang; Komaki, Yukako; Kimura, Susana Y; Hu, Hong-Ying; Wagner, Elizabeth D; Mariñas, Benito J; Plewa, Michael J

    2014-10-21

    Disinfectants inactivate pathogens in source water; however, they also react with organic matter and bromide/iodide to form disinfection byproducts (DBPs). Although only a few DBP classes have been systematically analyzed for toxicity, iodinated and brominated DBPs tend to be the most toxic. The objectives of this research were (1) to determine if monochloramine (NH2Cl) disinfection generated drinking water with less toxicity than water disinfected with free chlorine (HOCl) and (2) to determine the impact of added bromide and iodide in conjunction with HOCl or NH2Cl disinfection on mammalian cell cytotoxicity and genomic DNA damage induction. Water disinfected with chlorine was less cytotoxic but more genotoxic than water disinfected with chloramine. For both disinfectants, the addition of Br(-) and I(-) increased cytotoxicity and genotoxicity with a greater response observed with NH2Cl disinfection. Both cytotoxicity and genotoxicity were highly correlated with TOBr and TOI. However, toxicity was weakly and inversely correlated with TOCl. Thus, the forcing agents for cytotoxicity and genotoxicity were the generation of brominated and iodinated DBPs rather than the formation of chlorinated DBPs. Disinfection practices need careful consideration especially when using source waters containing elevated bromide and iodide.

  9. Observations on Salmonella contamination of commercial duck farms before and after cleaning and disinfection.

    Science.gov (United States)

    Martelli, Francesca; Gosling, Rebecca J; Callaby, Rebecca; Davies, Rob

    2017-04-01

    In the European Union, statutory control of Salmonella is in place in the chicken and turkey sectors, but not in the duck sector. In this study, 14 Salmonella-positive duck farms were sampled before and after cleaning and disinfection, and once the houses had been restocked with a new flock. The cleaning and disinfection programmes used were subdivided into two main categories: ones in which a final formaldehyde disinfection step was included (1) and ones in which it was not included (2). Several types of samples were collected during the study, and faecal samples were those more frequently positive (62% of faecal samples were positive for Salmonella in comparison to 2-23% of samples from all the other sample categories) (P cleaning and disinfection programme used, there was a statistically significant (P cleaning and disinfection (41.1%) and after cleaning and disinfection (3.1%). After restocking, the number of Salmonella-positive samples increased significantly (P disinfection programme 1 was used were 5.34 times less likely to have samples positive for Salmonella after cleaning and disinfection than farms which implemented programme 2. Formaldehyde acts effectively against Salmonella even in the presence of some residual organic matter. Limited residual contamination on farms after cleaning and disinfection represents a risk of infection for young ducklings, and thorough cleaning and disinfection procedures should be implemented to reduce the carry-over of infection between flocks.

  10. Resistance of Pseudomonas aeruginosa isolates to hydrogel contact lens disinfection correlates with cytotoxic activity.

    Science.gov (United States)

    Lakkis, C; Fleiszig, S M

    2001-04-01

    One of the most common pathogens in infection of hydrogel contact lens wearers is Pseudomonas aeruginosa, which can gain access to the eye via contamination of the lens, lens case, and lens care solutions. Only one strain per species is used in current regulatory testing for the marketing of chemical contact lens disinfectants. The aim of this study was to determine whether P. aeruginosa strains vary in their susceptibility to hydrogel contact lens disinfectants. A method for rapidly screening bacterial susceptibility to contact lens disinfectants was developed, based on measurement of the MIC. The susceptibility of 35 P. aeruginosa isolates to two chemical disinfectants was found to vary among strains. MICs ranged from 6.25 to 100% for both disinfectants at 37 degrees C, and a number of strains were not inhibited by a 100% disinfectant concentration in the lens case environment at room temperature (22 degrees C). Resistance to disinfection appeared to be an inherent rather than acquired trait, since some resistant strains had been isolated prior to the introduction of the disinfectants and some susceptible P. aeruginosa strains could not be made more resistant by repeated disinfectant exposure. A number of P. aeruginosa strains which were comparatively more resistant to short-term disinfectant exposure also demonstrated the ability to grow to levels above the initial inoculum in one chemical disinfectant after long-term (24 to 48 h) disinfectant exposure. Resistance was correlated with acute cytotoxic activity toward corneal epithelial cells and with exsA, which encodes a protein that regulates cytotoxicity via a complex type III secretion system. These results suggest that chemical disinfection solutions may select for contamination with cytotoxic strains. Further investigation of the mechanisms and factors responsible for resistance may also lead to strategies for reducing adverse responses to contact lens wear.

  11. Childhood Emergencies

    Science.gov (United States)

    ... SUBSCRIBE Emergency 101 Share this! Home » Emergency 101 Childhood Emergencies Keeping children healthy and safe is every ... and tools to prevent, recognize and address a childhood emergency is the first step in keeping your ...

  12. Eye Emergencies

    Science.gov (United States)

    ... The Marfan Foundation Marfan & Related Disorders What is Marfan Syndrome? What are Related Disorders? What are the Signs? ... Emergencies Eye Emergencies Lung Emergencies Surgeries Eye Emergencies Marfan syndrome significantly increases your risk of retinal detachment, a ...

  13. Emergency contraception

    Science.gov (United States)

    Morning-after pill; Postcoital contraception; Birth control - emergency; Plan B; Family planning - emergency contraception ... IUD placed inside the uterus CHOICES FOR EMERGENCY CONTRACEPTION Two emergency contraceptive pills may be bought without a prescription. ...

  14. Strontium-90 fluoride data sheet

    Energy Technology Data Exchange (ETDEWEB)

    Fullam, H.T.

    1981-06-01

    This report is a compilation of available data and appropriate literature references on the properties of strontium-90 fluoride and nonradioactive strontium fluoride. The objective of the document is to compile in a single source pertinent data to assist potential users in the development, licensing, and use of /sup 90/SrF/sub 2/-fueled radioisotope heat sources for terrestrial power conversion and thermal applications. The report is an update of the Strontium-90 Fluoride Data Sheet (BNWL-2284) originally issued in April 1977.

  15. Vietnamese Hurricane Response Fact Sheets

    Science.gov (United States)

    Các tờ dữ kiện được cung cấp nơi đây mô tả vai trò của EPA trong việc đáp ứng với bão và cách các chương trình cụ thể cung cấp sự hỗ trợ. The Vietnamese fact sheets provided here describe EPA's role in a hurricane response.

  16. Photovoltaic powered ultraviolet and visible light-emitting diodes for sustainable point-of-use disinfection of drinking waters.

    Science.gov (United States)

    Lui, Gough Yumu; Roser, David; Corkish, Richard; Ashbolt, Nicholas; Jagals, Paul; Stuetz, Richard

    2014-09-15

    For many decades, populations in rural and remote developing regions will be unable to access centralised piped potable water supplies, and indeed, decentralised options may be more sustainable. Accordingly, improved household point-of-use (POU) disinfection technologies are urgently needed. Compared to alternatives, ultraviolet (UV) light disinfection is very attractive because of its efficacy against all pathogen groups and minimal operational consumables. Though mercury arc lamp technology is very efficient, it requires frequent lamp replacement, involves a toxic heavy metal, and their quartz envelopes and sleeves are expensive, fragile and require regular cleaning. An emerging alternative is semiconductor-based units where UV light emitting diodes (UV-LEDs) are powered by photovoltaics (PV). Our review charts the development of these two technologies, their current status, and challenges to their integration and POU application. It explores the themes of UV-C-LEDs, non-UV-C LED technology (e.g. UV-A, visible light, Advanced Oxidation), PV power supplies, PV/LED integration and POU suitability. While UV-C LED technology should mature in the next 10 years, research is also needed to address other unresolved barriers to in situ application as well as emerging research opportunities especially UV-A, photocatalyst/photosensitiser use and pulsed emission options. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Initial rigid response and softening transition of highly stretchable kirigami sheet materials.

    Science.gov (United States)

    Isobe, Midori; Okumura, Ko

    2016-04-27

    We study, experimentally and theoretically, the mechanical response of sheet materials on which line cracks or cuts are arranged in a simple pattern. Such sheet materials, often called kirigami (the Japanese words, kiri and gami, stand for cut and paper, respectively), demonstrate a unique mechanical response promising for various engineering applications such as stretchable batteries: kirigami sheets possess a mechanical regime in which sheets are highly stretchable and very soft compared with the original sheets without line cracks, by virtue of out-of-plane deformation. However, this regime starts after a transition from an initial stiff regime governed by in-plane deformation. In other words, the softness of the kirigami structure emerges as a result of a transition from the two-dimensional to three-dimensional deformation, i.e., from stretching to bending. We clarify the physical origins of the transition and mechanical regimes, which are revealed to be governed by simple scaling laws. The results could be useful for controlling and designing the mechanical response of sheet materials including cell sheets for medical regeneration and relevant to the development of materials with tunable stiffness and mechanical force sensors.

  18. AI applications in sheet metal forming

    CERN Document Server

    Hussein, Hussein

    2017-01-01

    This book comprises chapters on research work done around the globe in the area of artificial intelligence (AI) applications in sheet metal forming. The first chapter offers an introduction to various AI techniques and sheet metal forming, while subsequent chapters describe traditional procedures/methods used in various sheet metal forming processes, and focus on the automation of those processes by means of AI techniques, such as KBS, ANN, GA, CBR, etc. Feature recognition and the manufacturability assessment of sheet metal parts, process planning, strip-layout design, selecting the type and size of die components, die modeling, and predicting die life are some of the most important aspects of sheet metal work. Traditionally, these activities are highly experience-based, tedious and time consuming. In response, researchers in several countries have applied various AI techniques to automate these activities, which are covered in this book. This book will be useful for engineers working in sheet metal industri...

  19. Dynamics of Radially Expanding Liquid Sheets

    Science.gov (United States)

    Majumdar, Nayanika; Tirumkudulu, Mahesh S.

    2018-04-01

    The process of atomization often involves ejecting thin liquid sheets at high speeds from a nozzle that causes the sheet to flap violently and break up into fine droplets. The flapping of the liquid sheet has long been attributed to the sheet's interaction with the surrounding gas phase. Here, we present experimental evidence to the contrary and show that the flapping is caused by the thinning of the liquid sheet as it spreads out from the nozzle exit. The measured growth rates of the waves agree remarkably well with the predictions of a recent theory that accounts for the sheet's thinning but ignores aerodynamic interactions. We anticipate these results to not only lead to more accurate predictions of the final drop-size distribution but also enable more efficient designs of atomizers.

  20. Study on a New Ultraviolet Sterilizer to the Surface Disinfection of the Ultrasound Probe.

    Science.gov (United States)

    Chen, Gui Qiu; Chen, Yu Hao; Yi, Liang; Yin, Jin; Gao, Qiong; Song, Jiang Nan; Li, Shi Kang; Chen, Pei Hou; Guo, Gui Ping

    2018-02-01

    We studied the disinfection effect of a new ultraviolet (UV) sterilizer and its utilization on ultrasound probe surfaces. Carrier quantitative germicidal tests, simulated on-the-spot trials, and organic substance influence tests were used to carry out experimental observation. Artificially infected probes were disinfected using the sterilizer or a germicidal lamp for comparison. The total number and types of bacteria were determined and identified. Our results demonstrated the sterilizer had the best disinfection effect among three different disinfection methods in hospital. The sterilizer has been used in a hospital setting for 2 years with no notable damage to the ultrasound probe instrument. It has the advantages of fast disinfection, high disinfection effect, and good compatibility with the ultrasound instrument, worthy of being a promoted application in medical institutions. Copyright © 2018 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  1. Activity of disinfectants against foodborne pathogens in suspension and adhered to stainless steel surfaces

    Directory of Open Access Journals (Sweden)

    Tatiane Karen Cabeça

    2012-09-01

    Full Text Available The purpose of this study was to investigate and compare the efficacy of various disinfectants on planktonic cells and biofilm cells of Listeria monocytogenes, Staphylococcus aureus and Escherichia coli. Numbers of viable biofilm cells decreased after treatment with all tested disinfectants (iodine, biguanide, quaternary ammonium compounds, peracetic acid and sodium hypochlorite. Sodium hypochlorite was the most effective disinfectant against biofilm cells, while biguanide was the least effective. Scanning electron microscopy observations revealed that cells adhered on stainless steel surface after treatment with the disinfectants. No viable planktonic cells were observed after treatment with the same disinfectants. Based on our findings, we concluded that biofilm cells might be more resistant to disinfectants than plancktonic cells.

  2. Thermal disinfection of hotels, hospitals, and athletic venues hot water distribution systems contaminated by Legionella species.

    Science.gov (United States)

    Mouchtouri, Varvara; Velonakis, Emmanuel; Hadjichristodoulou, Christos

    2007-11-01

    Legionella spp. (> or = 500 cfu liter(-1)) were detected in 92 of 497 water distribution systems (WDS) examined. Thermal disinfection was applied at 33 WDS. After the first and second application of the disinfection procedure, 15 (45.4%) and 3 (9%) positive for remedial actions WDS were found, respectively. Legionella pneumophila was more resistant to thermal disinfection than Legionella non-pneumophila spp. (relative risk [RR]=5.4, 95% confidence intervals [CI]=1-35). WDS of hotels with oil heater were more easily disinfected than those with electrical or solar heater (RR=0.4 95% CI=0.2-0.8). Thermal disinfection seems not to be efficient enough to eliminate legionellae, unless repeatedly applied and in combination with extended heat flushing, and faucets chlorine disinfection.

  3. Chemical surface disinfection of eggs of Baltic cod, Gadus morhua L

    DEFF Research Database (Denmark)

    Overton, J L; Bruun, Morten Sichlau; Dalsgaard, Inger

    2010-01-01

    The effect of two disinfectants on eggs and larvae of Baltic cod, Gadus morhua, was investigated. The eggs were disinfected for 10 min using various concentrations of either glutaraldehyde (100, 200, 400, 600 and 800 mg L−1) or iodophor (10, 50, 100 and 150 mg L−1), 1–4-days post......-fertilization. Bactericidal effect of disinfection, survival to hatching, hatching success and larval abnormalities were assessed. Larval survival was recorded at 5-, 10- and 15-days post-hatch (dph). Although Baltic cod eggs have an unusually thin chorion, they could tolerate surface disinfection. A reduction in bacterial...... growth was observed with increased concentrations of disinfectant (3.0 × 107–1.6 × 101 CFU mL−1). Abnormalities in newly hatched larvae were not related to disinfection. Survival of the yolk sac larvae was significantly better for eggs treated with 400 mg L−1 glutaraldehyde for 10 min at 10 and 15 dph...

  4. Laboratory and field investigation of chemical disinfection of combined sewer overflow in Copenhagen area

    DEFF Research Database (Denmark)

    Chhetri, Ravi Kumar; Thornberg, Dines; Berner, Jesper

    We investigated the possibility to apply performic acid (PFA) and peracetic acid (PAA) for disinfection of combined sewer overflow (CSO) in existing CSO management infrastructures. The disinfection power of PFA and PAA to Escherichia coli (E. coli) and enterococcus were studied in batch scale...... and pre-field experiment. In batch scale experiment 2.5 mg·L -1 PAA removed around 4 log unit of E. coli and enterococcus from CSO with long contact time. Removal of E. coli and enterococcus from CSO were always around or above 3 log unit using 2-4 mg·L -1 PFA with short contact time in batch scale...... and pre-field experiment. There were no toxicological effect measured by Vibrio fischeri when CSO was disinfected with PFA, slight toxicological effect was observed on CSO disinfected with PAA. When the design for PFA based disinfection was applied to CSO collected from an authentic event. Disinfection...

  5. Field evaluation of ZeroFly--an insecticide incorporated plastic sheeting against malaria vectors & its impact on malaria transmission in tribal area of northern Orissa.

    Science.gov (United States)

    Sharma, S K; Upadhyay, A K; Haque, M A; Tyagi, P K; Mohanty, S S; Mittal, P K; Dash, A P

    2009-10-01

    Insecticide incorporated plastic sheeting is a new technology to control mosquitoes in emergency shelter places and also temporary habitations in different locations. Therefore, field studies were conducted to assess the efficacy of ZeroFly plastic sheeting treated with deltamethrin on prevailing disease vectors Anopheles culicifacies and An. fluviatilis and its impact on malaria transmission in one of the highly endemic areas of Orissa. The study was conducted in Birkera block of Sundargarh district, Orissa state. The study area comprised 3 villages, which were randomized as ZeroFly plastic sheet, untreated plastic sheet and no sheet area. ZeroFly plastic sheets and untreated plastic sheets were fixed in study and control villages respectively covering all the rooms in each household. Longitudinal studies were conducted on the bioefficacy with the help of cone bioassays, monitoring of the mosquito density through hand catch, floor sheet and exit trap collections and fortnightly domiciliary active surveillance in all the study villages. In ZeroFly plastic sheeting area, there was a significant reduction of 84.7 per cent in the entry rate of total mosquitoes in comparison to pre-intervention phase. There was 56.2 per cent immediate mortality in total mosquitoes in houses with ZeroFly sheeting. The overall feeding success rate of mosquitoes in the trial village was only 12.5 per cent in comparison to 49.7 and 51.1 per cent in villages with untreated plastic sheet and no sheet respectively. There was a significant reduction of 65.0 and 70.5 per cent in malaria incidence in ZeroFly plastic sheeting area as compared to untreated plastic sheet and no sheet area respectively. Our study showed that introduction of ZeroFly plastic sheets in a community-based intervention programme is operationally feasible to contain malaria especially in the high transmission difficult areas.

  6. Microbial electrolytic disinfection process for highly efficient Escherichia coli inactivation

    DEFF Research Database (Denmark)

    Zhou, Shaofeng; Huang, Shaobin; Li, Xiaohu

    2018-01-01

    extensively studied for recalcitrant organics removal, its application potential towards water disinfection (e.g., inactivation of pathogens) is still unknown. This study investigated the inactivation of Escherichia coli in a microbial electrolysis cell based bio-electro-Fenton system (renamed as microbial......Water quality deterioration caused by a wide variety of recalcitrant organics and pathogenic microorganisms has become a serious concern worldwide. Bio-electro-Fenton systems have been considered as cost-effective and highly efficient water treatment platform technology. While it has been......]OH was identified as one potential mechanism for disinfection. This study successfully demonstrated the feasibility of bio-electro-Fenton process for pathogens inactivation, which offers insight for the future development of sustainable, efficient, and cost-effective biological water treatment technology....

  7. Chlorine dioxine DBPs (disinfection by-products in drinking water

    Directory of Open Access Journals (Sweden)

    C. Lasagna

    2013-01-01

    Full Text Available Since the 1970s it has been well known that, though water for human consumption is generally disinfected before being distributed along the network, the use of chemicals results in the formation of many different Disinfection By-Products (DBPs. In the case of chlorine dioxide, the most important and represented DBPs are chlorite and chlorate: after an introduction concerning the current Italian regulation on this subject, in the experimental part the results of a 7-year minitoring campaign, concerning water of different origin collected from taps in various Italian regions, are shown. The analytical technique used for the determination of chlorite and chlorate was Ion Chromatography. The result obtained are finally discussed.

  8. Disinfection of treated sewage. [Ultra-violet irradiation

    Energy Technology Data Exchange (ETDEWEB)

    From, J O

    1976-09-02

    The release of treated sewage in the vicinity of bathing places, drinking water sources or fish and shellfish culture plants is undesirable due to high bacterial content. Disinfection by chlorine would be relatively expensive and the toxicity would result in a local dead zone. The formation of small, but measurable, amounts of persistent chlorated hydrocarbons could also lead to long-term biological effects. Disinfection by ozone or gamma radiation would involve investments unacceptable in small plants. Ultraviolet radiation with wavelength 2500-2600 A has a powerful bacteriocidal effect and has been demonstrated to give bacterial mortality of 99.96 to 99.997 %. A standard plant produced in USA with a capacity of 11.3 m/sup 3//h is illustrated. UV radiation has no effect on the chemical composition of the water and the operating costs are low.

  9. Dose requirements for UVC disinfection of catheter biofilms

    DEFF Research Database (Denmark)

    Bak, Jimmy; Ladefoged, Søren D.; Tvede, Michael

    2009-01-01

    Bacterial biofilms on permanent catheters are the major sources of infection. Exposure to ultraviolet-C (UVC) light has been proposed as a method for disinfecting the inner surface of catheters. Specification of a UVC-based device for in vivo disinfection is based on the knowledge of the required...... doses to kill catheter biofilm. Given these doses and the power of available UVC light sources, calculation of the necessary treatment times is then possible. To determine the required doses, contaminated urinary catheters were used as test samples and UVC treated in vitro. Patient catheters (n = 67......) were collected and cut into segments of equal size and treated with various UVC doses. After treatment, the biofilm was removed by scraping and quantified by counting colony forming units. Percentage killing rates were determined by calculating ratios between UVC-treated samples and controls (no UVC...

  10. Sludge disinfection by combined treatment of bleaching powder and irradiation

    International Nuclear Information System (INIS)

    Harsoyo

    1987-01-01

    Sludge disinfection by combined treatment of bleaching powder and irradiation. Disinfection of sludge by combined treatment of bleaching powder and irradiation has been investigated. Sludge were obtained from water and waste sanitation department (Dinas Kebersihan) DKI located at Kebon Nanas, Jakarta. Sludge were mixed with bleaching powder at the concentration of 0, 10 and 20 mg/l and then irradiated in multipurpose panoramic batch irradiator (PANBIT) with doses of 2, 4, 6, 8, and 10 kGy and a dose rate 9 kGy/h. The reducing colony form unit caused by the combined treatment depend on type bacteria observed in sludge. Pathogenic bacteria as Clostridium still survive at a dose of 10 kGy on sludge containing 20 mg/l bleaching powder, but Salmonella, Shigella, and Vibrio were not detected in this experiment, neither in the control nor in the irradiated samples. (author). 14 refs.; 4 figs

  11. Shape Optimization of Swimming Sheets

    Energy Technology Data Exchange (ETDEWEB)

    Wilkening, J.; Hosoi, A.E.

    2005-03-01

    The swimming behavior of a flexible sheet which moves by propagating deformation waves along its body was first studied by G. I. Taylor in 1951. In addition to being of theoretical interest, this problem serves as a useful model of the locomotion of gastropods and various micro-organisms. Although the mechanics of swimming via wave propagation has been studied extensively, relatively little work has been done to define or describe optimal swimming by this mechanism.We carry out this objective for a sheet that is separated from a rigid substrate by a thin film of viscous Newtonian fluid. Using a lubrication approximation to model the dynamics, we derive the relevant Euler-Lagrange equations to optimize swimming speed and efficiency. The optimization equations are solved numerically using two different schemes: a limited memory BFGS method that uses cubic splines to represent the wave profile, and a multi-shooting Runge-Kutta approach that uses the Levenberg-Marquardt method to vary the parameters of the equations until the constraints are satisfied. The former approach is less efficient but generalizes nicely to the non-lubrication setting. For each optimization problem we obtain a one parameter family of solutions that becomes singular in a self-similar fashion as the parameter approaches a critical value. We explore the validity of the lubrication approximation near this singular limit by monitoring higher order corrections to the zeroth order theory and by comparing the results with finite element solutions of the full Stokes equations.

  12. Magnetic properties of sheet silicates

    International Nuclear Information System (INIS)

    Ballet, O.; Coey, J.M.D.

    1982-01-01

    Susceptibility, magnetisation and Moessbauer measurements are reported for a representative selection of 2:1 layer phyllosilicates. Eight samples from the mica, vermiculite and smectite groups include examples diluted in iron which are paramagnetic at all temperatures, as well as iron-rich silicates which order magnetically below 10 K. Anisotropic susceptibility of crystals of muscovite, biotite and vermiculite is quantitatively explained with a model where the Fe 2+ ions lie in sites of effective trigonal symmetry, the trigonal axis lying normal to the sheets. The ferrous ground state is an orbital singlet. Ferric iron gives an isotropic contribution to the susceptibility. Fe 2+ -Fe 2+ exchange interactions are ferromagnetic with Gapprox. equal to2 K, whereas Fe 3+ -Fe 3+ coupling is antiferromagnetic in the purely ferric minerals. A positive paramagnetic Curie temperature for glauconite may be attributable to Fe 2+ → Fe 3+ charge transfer. Magnetic order was found to set in inhomogeneously for glauconite at 1-7 K. One biotite sample showed an antiferromagnetic transition at Tsub(N) = 7 K marked by a well-defined susceptibility maximum. Its magnetic structure, consisting of ferromagnetic sheets with moments in their planes coupled antiferromagnetically by other, weak interactions, resembles that found earlier for the 1:1 mineral greenalite. (orig.)

  13. Solar disinfection of drinking water and oral rehydration solutions

    Energy Technology Data Exchange (ETDEWEB)

    Acra, A; Raffoul, Z; Karahagopian, Y

    1984-01-01

    This document provides concise information on oral rehydration therapy for the control of diarrheal diseases in developing countries; however, the main emphasis has been placed on the disinfection of oral rehydration solutions, or the water used in their preparation, as achieved by exposure to sunlight in transparent containers. The fundamental principles of solar energy are presented as well as studies which demonstrate the efficacy of the method. 2 figures, 6 tables.

  14. Inactivation Effect of Antibiotic-Resistant Gene Using Chlorine Disinfection

    Directory of Open Access Journals (Sweden)

    Takashi Furukawa

    2017-07-01

    Full Text Available The aim of this study was to elucidate the inactivation effects on the antibiotic-resistance gene (vanA of vancomycin-resistant enterococci (VRE using chlorination, a disinfection method widely used in various water treatment facilities. Suspensions of VRE were prepared by adding VRE to phosphate-buffered saline, or the sterilized secondary effluent of a wastewater treatment plant. The inactivation experiments were carried out at several chlorine concentrations and stirring time. Enterococci concentration and presence of vanA were determined. The enterococci concentration decreased as chlorine concentrations and stirring times increased, with more than 7.0 log reduction occurring under the following conditions: 40 min stirring at 0.5 mg Cl2/L, 20 min stirring at 1.0 mg Cl2/L, and 3 min stirring at 3.0 mg Cl2/L. In the inactivation experiment using VRE suspended in secondary effluent, the culturable enterococci required much higher chlorine concentration and longer treatment time for complete disinfection than the cases of suspension of VRE. However, vanA was detected in all chlorinated suspensions of VRE, even in samples where no enterococcal colonies were present on the medium agar plate. The chlorine disinfection was not able to destroy antibiotic-resistance genes, though it can inactivate and decrease bacterial counts of antibiotic-resistant bacteria (ARB. Therefore, it was suggested that remaining ARB and/or antibiotic-resistance gene in inactivated bacterial cells after chlorine disinfection tank could be discharged into water environments.

  15. Iodine Disinfection in the Use of Individual Water Purification Devices

    Science.gov (United States)

    2006-03-01

    Effect of Resin Disinfectants-I3 and –I5 on Giardia muris and Giardia lamblia. Applied and Environmental Microbiology, 46(5), 965-969. 24. AWWA... Giardia or Cryptosporidium). Iodine-using IWPDs meeting these standards are considered effective against disease causing bacteria, viruses, and...CT = 65 mg-min/L) for a 2-log inactivation of E. histolytica cysts (references 9 and 10). Another study using Giardia cysts showed CT’s up to 3

  16. Automation of air disinfection and lighting in agricultural buildings

    Directory of Open Access Journals (Sweden)

    L. Yu. Yuferev

    2017-01-01

    Full Text Available The article describes the urgency of this problem and modern ways of its solving. Modern disinfection and lighting systems are not developed enough. The authors proposed to automate the system of disinfection, dust removal and lighting in the farm building. We developed algorithm on the basis of which the universal program in the programming language C ++ was written. Assembled the microprocessor set ARDUINO. The program is included in the microprocessor ATMEGA, which is part of ARDUINO. As a basis for the disinfection system, a two-component ARUF device was used, which includes two decontaminating components: an ultraviolet lamp and an aerosol dispenser. Each of the algorithms (lighting and disinfection consists of 3 parts: data collection and analysis, control, data output to the display. The sequence of 3 parts is 1 cycle, then it repeated. In the first part on the basis of indications of sensors assignment to variables of some values was carried out. In the second part, based on the values of the variables, the decontamination and lighting devices are controlled. In the third part due to changing the screen number, variable, it is possible to switch the display and view the status of the installation and external parameters. The program, written on the basis of algorithms, is universal and suitable for almost any poultry and livestock buildings. All parameters (the time of the beginning and completion of the ARUV operation within 24 hours, the daily time of the illumination of a certain cycle, the maximum and minimum humidity, the duration of each cycle used for control and management are variables. Operator can set the items using the display in the menu.

  17. Suitability of electrolyzed oxidizing water for the disinfection of hard surfaces and equipment in radiology

    OpenAIRE

    Pintaric, Robert; Matela, Joze; Pintaric, Stefan

    2015-01-01

    Background Hospitals are faced with increasingly resistant strains of micro-organisms. When it comes to disinfection, individual parts of electronic equipment of angiology diagnostics such as patient couches of computer tomography (CT) and magnetic resonance imaging (MRI) scanners prove to be very hard to disinfect. Disinfectants of choice are therefore expected to possess properties such as rapid, residue-free action without any damaging effect on the sensitive electronic equipment. This pap...

  18. Exposure characteristics of familial cases of lung injury associated with the use of humidifier disinfectants

    OpenAIRE

    Park, Donguk; Leem, Jonghan; Lee, Kyoungmu; Lim, Heungkyu; Choi, Yeyong; Ahn, Jong-Ju; Lim, Sinye; Park, Jeongim; Choi, Kyungho; Lee, Naroo; Jung, Hyejung; Ha, Jongsik; Paek, Domyung

    2014-01-01

    Background This study describes 17 families with 38 lung injury patients (14 males, 24 females; 22 preschool-age children less than six years of age and 16 individuals of 13–50 years) who used disinfectant added to humidifiers in the home. Methods Clinical examination and humidifier disinfectant-use histories were taken, and a thorough home investigation was performed to assess exposure to humidifier disinfectant. Results Nine of the patients (three pregnant females, six preschool-age childre...

  19. Association of high-level humidifier disinfectant exposure with lung injury in preschool children.

    Science.gov (United States)

    Park, Dong-Uk; Ryu, Seung-Hun; Roh, Hyun-Suk; Lee, Eun; Cho, Hyun-Ju; Yoon, Jisun; Lee, So-Yeon; Cho, Young Ah; Do, Kyung-Hyun; Hong, Soo-Jong

    2018-03-01

    Children aged ≤6years reportedly account for 52% of victims of humidifier disinfectant-associated lung injuries. To evaluate the association of humidifier disinfectants with lung injury risk among children aged ≤6years. Patients with humidifier disinfectant-associated lung injuries (n=214) who were clinically evaluated to have a definite (n=108), probable (n=49), or possible (n=57) association with humidifier disinfectants as well as control patients (n=123) with lung injury deemed unlikely to be associated with humidifier disinfectant use were evaluated to determine factors associated with increased risk of humidifier disinfectant-associated lung injury using unconditional multiple logistic regression analysis. For estimated airborne humidifier disinfectant concentrations, risk of humidifier disinfectant-associated lung injury increased ≥two-fold in a dose-dependent manner in the highest quartile (Q4, 135-1443μg/m 3 ) compared with that in the lowest quartile (Q1, ≤33μg/m 3 ). Registered patients using more than two humidifier disinfectant brands were at an increased risk of humidifier disinfectant-associated lung injury (adjusted OR, 2.2; 95% confidence interval, 1.3-3.8) compared with those using only one brand. With respect to the duration of humidifier disinfectant use, risk of humidifier disinfectant-associated lung injury increased ≥two-fold in the lowest quartile (≤5months) compared with that in the highest quartile (≥14months; adjusted OR 0.3; 95% confidence interval, 0.2-0.6). Younger children are more vulnerable to HDLI when exposed to HD chemicals within short period in early life. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Antiviral activity of a novel composition of peracetic acid disinfectant on parvoviruses

    Science.gov (United States)

    Dagher, Fadi; Jiang, Jun; Tijssen, Peter; Laliberté, Jean-François

    2017-01-01

    Porcine parvoviruses (PPV) are known to be particularly resistant to many disinfectants used to control other non-enveloped viruses. However, effective disinfectants used against PPV are harsh and corrosive to animal health facilities and the environment. We propose a noncorrosive “green” disinfectant that generates peracetic acid in-situ and is capable of inactivating PPV completely at a 1% concentration for a 10-minute contact time. PMID:28154460

  1. Weld Repair of Thin Aluminum Sheet

    Science.gov (United States)

    Beuyukian, C. S.; Mitchell, M. J.

    1986-01-01

    Weld repairing of thin aluminum sheets now possible, using niobium shield and copper heat sinks. Refractory niobium shield protects aluminum adjacent to hole, while copper heat sinks help conduct heat away from repair site. Technique limits tungsten/inert-gas (TIG) welding bombardment zone to melt area, leaving surrounding areas around weld unaffected. Used successfully to repair aluminum cold plates on Space Shuttle, Commercial applications, especially in sealing fractures, dents, and holes in thin aluminum face sheets or clad brazing sheet in cold plates, heat exchangers, coolers, and Solar panels. While particularly suited to thin aluminum sheet, this process also used in thicker aluminum material to prevent surface damage near weld area.

  2. Predicting Pulsar Scintillation from Refractive Plasma Sheets

    Science.gov (United States)

    Simard, Dana; Pen, Ue-Li

    2018-05-01

    The dynamic and secondary spectra of many pulsars show evidence for long-lived, aligned images of the pulsar that are stationary on a thin scattering sheet. One explanation for this phenomenon considers the effects of wave crests along sheets in the ionized interstellar medium, such as those due to Alfvén waves propagating along current sheets. If these sheets are closely aligned to our line-of-sight to the pulsar, high bending angles arise at the wave crests and a selection effect causes alignment of images produced at different crests, similar to grazing reflection off of a lake. Using geometric optics, we develop a simple parameterized model of these corrugated sheets that can be constrained with a single observation and that makes observable predictions for variations in the scintillation of the pulsar over time and frequency. This model reveals qualitative differences between lensing from overdense and underdense corrugated sheets: Only if the sheet is overdense compared to the surrounding interstellar medium can the lensed images be brighter than the line-of-sight image to the pulsar, and the faint lensed images are closer to the pulsar at higher frequencies if the sheet is underdense, but at lower frequencies if the sheet is overdense.

  3. Emerging Contaminants and Federal Facility Contaminants of Concern

    Science.gov (United States)

    This page links to fact sheets summarizing contaminants of concern and emerging contaminants that present unique issues and challenges to the environmental community in general and to FFRRO in particular.

  4. Antifungal efficacy of hydrogen peroxide in dental unit waterline disinfection.

    Science.gov (United States)

    Szymańska, Jolanta

    2006-01-01

    The concentration and composition of fungal flora in dental unit waterlines (DUWL) were evaluated. For this purpose, water samples from unit reservoirs and high-speed handpieces, and biofilm samples from the waterline walls from units were collected. Subsequently, analogous samples from DUWL were taken before and after disinfection using agent containing hydrogen peroxide. In the examined samples, the yeast-like fungi Candida albicans and Candida curvata were found. The following species of mould were also identified: Aspergillus amstelodami, Aspergillus fumigatus, Aspergillus glaucus group, Aspergillus (=Eurotium herbariorum) repens, Citromyces spp., Geotrichum candidum, Penicillium (glabrum) frequentans, Penicillium pusillum, Penicillium turolense and Sclerotium sclerotiorum (Sclerotinia sclerotiorum). Before disinfection, Candida curvata and Candida albicans constituted the greatest proportion of the total fungi in the reservoirs water; in the water of handpieces--Candida albicans and Aspergillus glaucus group; and in the biofilm samples--Aspergillus glaucus group and Candida albicans. After disinfection, in all 3 kinds of samples, Candida albicans prevailed, constituting from 31.2-85.7 % of the total fungi. The application of agent containing hydrogen peroxide caused a significant decrease both in the number of total fungi and individual fungal species, which confirms the product effectiveness in fungal decontamination of DUWL.

  5. Sludge disinfection using gamma radiation: a sound option for Albuquerque

    International Nuclear Information System (INIS)

    Noland, P.D.; Khera, A.K.

    1980-01-01

    The City of Albuquerque has disposed of its anaerobically digested dried sludge cake on City and county parks for many years. If the City is to continue such beneficial use of sludge, it must now provide a supplementary disinfection process in order to meet the recent EPA regulations governing land application of sewage sludges. In light of these recent regulations and soaring costs of electrical energy, the City of Albuquerque recently completed a comprehensive sludge management study. This study is intended to supplement the areawide facilities plan completed in 1976. Among the various alternatives evaluated, the most feasible was the continued use of dried sludge cake on City parks and sale of excess sludge cake as an unlimited use soil conditioner and fertilizer. This sludge would be disinfected by gamma irradiation. The proposed solids management system would consist of two-stage anaerobic digestion and pipeline transfer to dewatering, disinfection, and stockpiling facilities at a remote tract approximately 5 miles from the treatment plant

  6. Wastewater disinfection by combination of ultrasound and ultraviolet irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Naddeo, V., E-mail: vnaddeo@unisa.it [Department of Civil Engineering, University of Salerno, Via Ponte don Melillo, 1, 84084 Fisciano (Italy); Landi, M.; Belgiorno, V. [Department of Civil Engineering, University of Salerno, Via Ponte don Melillo, 1, 84084 Fisciano (Italy); Napoli, R.M.A. [Department of Environmental Science, University of Napoli Parthenope, Via Amm. F. Acton, 38, 80133 Napoli (Italy)

    2009-09-15

    Reclamation and reuse of wastewater is one of the most effective ways to alleviate water resource scarcity. In many countries very stringent limit for chlorination by-products such as trihalomethanes has been set for wastewater reuse. Accordingly, the use of alternative oxidation/disinfection systems should be evaluated as possible alternative to chlorine. Recently ultrasound (US) was found to be effective as pre-treatment for wastewater disinfection by UV irradiation. The aim of this work is to investigate the wastewater advanced treatment by simultaneous combination of UV and US in terms of bacteria inactivation (Total coliform and Escherichia coli) at pilot-scale. The pilot plant was composed of two reactors: US-UV reactor and UV reactor. The influence of different reaction times, respective US and UV dose and synergistic effect was tested and discussed for two different kinds of municipal wastewater. An important enhancement of UV disinfection ability has been observed in presence of US, especially with wastewater characterized by low transmittance. In particular the inactivation was greater for T. coliform than for E. coli. Furthermore, the results obtained showed also that the fouling formation on the lamps was slower in US-UV reactor than in UV reactor both with and without solar radiation.

  7. Wastewater disinfection by combination of ultrasound and ultraviolet irradiation

    International Nuclear Information System (INIS)

    Naddeo, V.; Landi, M.; Belgiorno, V.; Napoli, R.M.A.

    2009-01-01

    Reclamation and reuse of wastewater is one of the most effective ways to alleviate water resource scarcity. In many countries very stringent limit for chlorination by-products such as trihalomethanes has been set for wastewater reuse. Accordingly, the use of alternative oxidation/disinfection systems should be evaluated as possible alternative to chlorine. Recently ultrasound (US) was found to be effective as pre-treatment for wastewater disinfection by UV irradiation. The aim of this work is to investigate the wastewater advanced treatment by simultaneous combination of UV and US in terms of bacteria inactivation (Total coliform and Escherichia coli) at pilot-scale. The pilot plant was composed of two reactors: US-UV reactor and UV reactor. The influence of different reaction times, respective US and UV dose and synergistic effect was tested and discussed for two different kinds of municipal wastewater. An important enhancement of UV disinfection ability has been observed in presence of US, especially with wastewater characterized by low transmittance. In particular the inactivation was greater for T. coliform than for E. coli. Furthermore, the results obtained showed also that the fouling formation on the lamps was slower in US-UV reactor than in UV reactor both with and without solar radiation.

  8. Formation of trihalomethanes as disinfection byproducts in herbal spa pools.

    Science.gov (United States)

    Fakour, Hoda; Lo, Shang-Lien

    2018-04-09

    Herbal spa treatments are favorite recreational activities throughout the world. The water in spas is often disinfected to control pathogenic microorganisms and guarantee hygiene. However, chlorinated water may cause the formation of disinfection byproducts (DBPs). Although there have been many studies on DBP formation in swimming pools, the role of organic matter derived from herbal medicines applied in herbal spa water has been largely neglected. Accordingly, the present study investigated the effect of herbal medicines on the formation of trihalomethanes (THMs) in simulated herbal spa water. Water samples were collected from a spa pool, and then, disinfection and herbal addition experiments were performed in a laboratory. The results showed that the organic molecules introduced by the herbal medicines are significant precursors to the formation of THMs in spa pool water. Since at least 50% of THMs were produced within the first six hours of the reaction time, the presence of herbal medicines in spa water could present a parallel route for THM exposure. Therefore, despite the undeniable benefits of herbal spas, the effect of applied herbs on DBP formation in chlorinated water should be considered to improve the water quality and health benefits of spa facilities.

  9. Disinfection of bore well water with chlorine dioxide/sodium hypochlorite and hydrodynamic cavitation.

    Science.gov (United States)

    Wang, Yifei; Jia, Aiyin; Wu, Yue; Wu, Chunde; Chen, Lijun

    2015-01-01

    The effect of hydrodynamic cavitation (HC) on potable water disinfection of chemicals was investigated. The bore well water was introduced into HC set-up to examine the effect of HC alone and combination of HC and chemicals such as chlorine dioxide and sodium hypochlorite. The effect of inlet pressure and geometrical parameters on disinfection was studied using HC alone and the results showed that increasing inlet pressure and using more and bigger holes of orifice plates can result in a higher disinfection rates. When HC was combined with chemicals, HC can reduce the doses of the chemicals and shorten the time of disinfection. It was also found that the decrease in bacteria concentration followed a first-order kinetic model. As for the experiment of combination of HC and sodium hypochlorite for disinfection, HC not only improves the disinfection rate but also degrades natural organic matter and chloroform. Compared with only sodium hypochlorite disinfection, combined processes get higher disinfection rate and lower production of chloroform, particularly the pretreatment with HC enhances the disinfection rate by 32% and there is a simultaneous reduction in production of chloroform by 39%.

  10. TiO{sub 2}-based photocatalytic disinfection of microbes in aqueous media: A review

    Energy Technology Data Exchange (ETDEWEB)

    Laxma Reddy, P.Venkata [Program in Environmental Science and Engineering, University of Texas El Paso, El Paso, TX 799038 (United States); Kavitha, Beluri [Department of Pharmacology, Kamineni Institute of Medical Sciences, Dr. NTRUHS, Vijayawada, Andhra Pradesh 520008 (India); Kumar Reddy, Police Anil [School of Chemical Engineering, Yeungnam University, Gyeongsan, Gyeongbuk 38541 (Korea, Republic of); Kim, Ki-Hyun, E-mail: kkim61@hanyang.ac.kr [Department of Civil & Environmental Engineering, Hanyang University, 222 Wangsimni-Ro, Seoul 04763 (Korea, Republic of)

    2017-04-15

    The TiO{sub 2} based photocatalyst has great potential for the disinfection/inactivation of harmful pathogens (such as E.coli in aqueous media) along with its well-known usefulness on various chemical pollutants. The disinfection property of TiO{sub 2} is primarily attributed to surface generation of reactive oxygen species (ROS) as well as free metal ions formation. Furthermore, its disinfection capacity and overall performance can be significantly improved through modifications of the TiO{sub 2} material. In this review, we provide a brief survey on the effect of various TiO{sub 2} materials in the disinfection of a wide range of environmentally harmful microbial pathogens (e.g., bacteria, fungi, algae, and viruses) in aqueous media. The influencing factors (such as reactor design, water chemistry, and TiO{sub 2} modifications) of such processes are discussed along with the mechanisms of such disinfection. It is believed that the combined application of disinfection and decontamination will greatly enhance the utilization of TiO{sub 2} photocatalyst as a potential alternative to conventional methods of water purification. - Highlights: • The advent of industrialization jeopardized the quality of drinking water. • TiO{sub 2} photocatalysis holds promise both in the degradation of pollutants and for disinfection. • The applicability of TiO{sub 2}-based decontamination is explored for microbial disinfection. • Here we provide a comprehensive review on titania-based photocatalysts for disinfection.

  11. In Vitro Evaluation of Dimensional Stability of Alginate Impressions after Disinfection by Spray and Immersion Methods

    Directory of Open Access Journals (Sweden)

    Fahimeh Hamedi Rad

    2010-12-01

    Full Text Available Background and aims. The most common method for alginate impression disinfection is spraying it with disinfecting agents, but some studies have shown that these impressions can be immersed, too. The aim of this study was to evaluate the dimensional stability of alginate impressions following disinfecting by spray and immersion methods. Materials and methods. Four common disinfecting agents (Sodium Hypochlorite, Micro 10, Glutaraldehyde and Deconex were selected and the impressions (n=108 were divided into four groups (n=24 and eight subgroups (n=12 for disinfecting by any of the four above-mentioned agents by spray or immersion methods. The control group (n=12 was not disinfected. Then the impressions were poured by type III Dental Stone Plaster in a standard method. The results were analyzed by descriptive methods (mean and standard deviation, t-test, two-way analysis of variance (ANOVA and Duncan test, using SPSS 14.0 software for windows. Results. The mean changes of length and height were significant between the various groups and disinfecting methods. Regarding the length, the greatest and the least amounts were related to Deconex and Micro 10 in the immersion method, respectively. Regarding height, the greatest and the least amounts were related to Glutaraldehyde and Deconex in the immersion method, respectively. Conclusion. Disinfecting alginate impressions by Sodium Hypochlorite, Deconex and Glutaraldehyde by immersion method is not recommended and it is better to disinfect alginate impressions by spraying of Micro 10, Sodium Hypochlorite, Glutaraldehyde and immersion in Micro 10.

  12. Chlorine disinfection of grey water for reuse: effect of organics and particles.

    Science.gov (United States)

    Winward, Gideon P; Avery, Lisa M; Stephenson, Tom; Jefferson, Bruce

    2008-01-01

    Adequate disinfection of grey water prior to reuse is important to prevent the potential transmission of disease-causing microorganisms. Chlorine is a widely utilised disinfectant and as such is a leading contender for disinfection of grey water intended for reuse. This study examined the impact of organics and particles on chlorine disinfection of grey water, measured by total coliform inactivation. The efficacy of disinfection was most closely linked with particle size. Larger particles shielded total coliforms from inactivation and disinfection efficacy decreased with increasing particle size. Blending to extract particle-associated coliforms (PACs) following chlorine disinfection revealed that up to 91% of total coliforms in chlorinated grey water were particle associated. The organic concentration of grey water affected chlorine demand but did not influence the disinfection resistance of total coliforms when a free chlorine residual was maintained. Implications for urban water reuse are discussed and it is recommended that grey water treatment systems target suspended solids removal to ensure removal of PACs prior to disinfection.

  13. Practical considerations in the use of UV light for drinking water disinfection

    International Nuclear Information System (INIS)

    Jeyanayagam, S.; Cotton, C.

    2002-01-01

    Ultraviolet (UV) light was discovered approximately 150 years ago. The first commercial UV lamp was made in the early 1900s soon followed by the manufacture of the quartz sleeve. These technological advances allowed the first application of UV light for water disinfection in 1907 in France. In the mid 1980s, UV disinfection was named as a Best available technology (BAT) for wastewater disinfection in the United States. Fueled by the recent findings that UV disinfection can inactivate key pathogens at cost effective UV doses, the drinking water industry in North America is closely investigating its application in large installations. (author)

  14. The efficiency of water treatment and disinfection by means of ultraviolet radiation

    International Nuclear Information System (INIS)

    Sobotka, J.

    1993-01-01

    Advantages and disadvantages of various water disinfection methods are discussed. The report examines the effectiveness of combined chlorine treatment and UV irradiation method of water disinfection and describes methods of determining UV radiation intensity, α absorption coefficient and radiation dose by means of measuring equipment constructed by the author. The α absorption coefficient dependence on the colour and turbidity of water exposed to radiation is defined. Enchytraeus albidus was applied as bioindicator in UV radiation intensity and disinfection effects measurements. The influence of UV radiation on microbiological, physical, chemical, and toxicological properties of water was determined. Prototype devices for water disinfection with UV radiation were made. (author)

  15. The efficiency of water treatment and disinfection by means of ultraviolet radiation

    Energy Technology Data Exchange (ETDEWEB)

    Sobotka, J [Medical Academy, Warsaw (Poland). Inst. of Social Medicine

    1993-01-01

    Advantages and disadvantages of various water disinfection methods are discussed. The report examines the effectiveness of combined chlorine treatment and UV irradiation method of water disinfection and describes methods of determining UV radiation intensity, [alpha] absorption coefficient and radiation dose by means of measuring equipment constructed by the author. The [alpha] absorption coefficient dependence on the colour and turbidity of water exposed to radiation is defined. Enchytraeus albidus was applied as bioindicator in UV radiation intensity and disinfection effects measurements. The influence of UV radiation on microbiological, physical, chemical, and toxicological properties of water was determined. Prototype devices for water disinfection with UV radiation were made. (author).

  16. Decontamination of B. globigii spores from drinking water infrastructure using disinfectants

    Data.gov (United States)

    U.S. Environmental Protection Agency — Decontamination of Bacillus spores adhered to common drinking water infrastructure surfaces was evaluated using a variety of disinfectants. Corroded iron and...

  17. Impact of universal disinfectant cap implementation on central line-associated bloodstream infections.

    Science.gov (United States)

    Merrill, Katreena Collette; Sumner, Sharon; Linford, Lorraine; Taylor, Carrie; Macintosh, Christopher

    2014-12-01

    Central line-associated bloodstream infections (CLABSIs) result in increased length of stay, cost, and patient morbidity and mortality. One CLABSI prevention method is disinfection of intravenous access points. The literature suggests that placing disinfectant caps over needleless connectors decreases CLABSI risk. A quasi-experimental intervention study was conducted in a >430-bed trauma I center. In addition to an existing standard central line bundle, a new intervention consisting of a luer-lock disinfectant cap with 70% alcohol was implemented in all intravenous (IV) needleless connectors on patients with peripheral and central lines. Compliance to the disinfectant cap was monitored weekly. A generalized linear model using a Poisson distribution was fit to determine if there were significant relationships between CLABSIs and disinfectant cap use. Impacts on costs were also examined. The rate of CLABSI decreased following implementation of the disinfectant cap. The incidence rate ratios (.577, P = .004) for implementing the disinfectant caps was statistically significant, indicating that the rate of patient infections decreased by >40%. Increased compliance rates were associated with lower infection rates. Disinfectant cap use was associated with an estimated savings of almost $300,000 per year in the hospital studied. Use of a disinfectant cap on IV needleless connectors in addition to an existing standard central line bundle was associated with decreased CLABSI and costs. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  18. Evaluation of disinfectants in the domestic environment under 'in use' conditions.

    Science.gov (United States)

    Scott, E.; Bloomfield, S. F.; Barlow, C. G.

    1984-01-01

    An 'in use' test was developed to investigate effectiveness of disinfectant application and of detergent of hot water cleaning at kitchen, bathroom and toilet sites in the domestic environment. Detergent and hot water cleaning produced no observable reduction in microbial contamination. Single and daily application tests demonstrated that hypochlorite and phenolic disinfectants can be used to produce substantial reductions in bacterial contamination in the home. Results indicate that maximum protection afforded by disinfection is relatively brief; 3-6 h after disinfection, contamination levels were only marginally less than those observed at pretreatment. Some suggestions are made for improvements in home hygiene. PMID:6323576

  19. Resistance of bacterial biofilms formed on stainless steel surface to disinfecting agent.

    Science.gov (United States)

    Królasik, Joanna; Zakowska, Zofia; Krepska, Milena; Klimek, Leszek

    2010-01-01

    The natural ability of microorganisms for adhesion and biofilm formation on various surfaces is one of the factors causing the inefficiency of a disinfection agent, despite its proven activity in vitro. The aim of the study was to determine the effectiveness of disinfecting substances on bacterial biofilms formed on stainless steel surface. A universally applied disinfecting agent was used in the tests. Bacterial strains: Listeria innocua, Pseudomonas putida, Micrococcus luteus, Staphylococcus hominis strains, were isolated from food contact surfaces, after a cleaning and disinfection process. The disinfecting agent was a commercially available acid specimen based on hydrogen peroxide and peroxyacetic acid, the substance that was designed for food industry usage. Model tests were carried out on biofilm formed on stainless steel (type 304, no 4 finish). Biofilms were recorded by electron scanning microscope. The disinfecting agent in usable concentration, 0.5% and during 10 minutes was ineffective for biofilms. The reduction of cells in biofilms was only 1-2 logarithmic cycles. The use of the agent in higher concentration--1% for 30 minutes caused reduction of cell number by around 5 logarithmic cycles only in the case of one microorganism, M. luteus. For other types: L. innocua, P. putida, S. hominis, the requirements placed on disinfecting agents were not fulfilled. The results of experiments proved that bacterial biofilms are resistant to the disinfectant applied in its operational parameters. Disinfecting effectiveness was achieved after twofold increase of the agent's concentration.

  20. Effective reprocessing of reusable dispensers for surface disinfection tissues – the devil is in the details

    Science.gov (United States)

    Kampf, Günter; Degenhardt, Stina; Lackner, Sibylle; Ostermeyer, Christiane

    2014-01-01

    Background: It has recently been reported that reusable dispensers for surface disinfection tissues may be contaminated, especially with adapted Achromobacter species 3, when products based on surface-active ingredients are used. Fresh solution may quickly become recontaminated if dispensers are not processed adequately. Methods: We evaluated the abilities of six manual and three automatic processes for processing contaminated dispensers to prevent recolonisation of a freshly-prepared disinfectant solution (Mikrobac forte 0.5%). Dispensers were left at room temperature for 28 days. Samples of the disinfectant solution were taken every 7 days and assessed quantitatively for bacterial contamination. Results: All automatic procedures prevented recolonisation of the disinfectant solution when a temperature of 60–70°C was ensured for at least 5 min, with or without the addition of chemical cleaning agents. Manual procedures prevented recontamination of the disinfectant solution when rinsing with hot water or a thorough cleaning step was performed before treating all surfaces with an alcohol-based disinfectant or an oxygen-releaser. Other cleaning and disinfection procedures, including the use of an alcohol-based disinfectant, did not prevent recolonisation. Conclusions: These results indicate that not all processes are effective for processing reusable dispensers for surface-disinfectant tissues, and that a high temperature during the cleaning step or use of a biofilm-active cleaning agent are essential. PMID:24653973

  1. Effective reprocessing of reusable dispensers for surface disinfection tissues – the devil is in the details

    Directory of Open Access Journals (Sweden)

    Kampf, Günter

    2014-03-01

    Full Text Available [english] Background: It has recently been reported that reusable dispensers for surface disinfection tissues may be contaminated, especially with adapted , when products based on surface-active ingredients are used. Fresh solution may quickly become recontaminated if dispensers are not processed adequately. Methods: We evaluated the abilities of six manual and three automatic processes for processing contaminated dispensers to prevent recolonisation of a freshly-prepared disinfectant solution (Mikrobac forte 0.5%. Dispensers were left at room temperature for 28 days. Samples of the disinfectant solution were taken every 7 days and assessed quantitatively for bacterial contamination. Results: All automatic procedures prevented recolonisation of the disinfectant solution when a temperature of 60–70°C was ensured for at least 5 min, with or without the addition of chemical cleaning agents. Manual procedures prevented recontamination of the disinfectant solution when rinsing with hot water or a thorough cleaning step was performed before treating all surfaces with an alcohol-based disinfectant or an oxygen-releaser. Other cleaning and disinfection procedures, including the use of an alcohol-based disinfectant, did not prevent recolonisation.Conclusions: These results indicate that not all processes are effective for processing reusable dispensers for surface-disinfectant tissues, and that a high temperature during the cleaning step or use of a biofilm-active cleaning agent are essential.

  2. Dynamic Antarctic ice sheet during the early to mid-Miocene

    Science.gov (United States)

    Gasson, Edward; DeConto, Robert M.; Pollard, David; Levy, Richard H.

    2016-03-01

    Geological data indicate that there were major variations in Antarctic ice sheet volume and extent during the early to mid-Miocene. Simulating such large-scale changes is problematic because of a strong hysteresis effect, which results in stability once the ice sheets have reached continental size. A relatively narrow range of atmospheric CO2 concentrations indicated by proxy records exacerbates this problem. Here, we are able to simulate large-scale variability of the early to mid-Miocene Antarctic ice sheet because of three developments in our modeling approach. (i) We use a climate-ice sheet coupling method utilizing a high-resolution atmospheric component to account for ice sheet-climate feedbacks. (ii) The ice sheet model includes recently proposed mechanisms for retreat into deep subglacial basins caused by ice-cliff failure and ice-shelf hydrofracture. (iii) We account for changes in the oxygen isotopic composition of the ice sheet by using isotope-enabled climate and ice sheet models. We compare our modeling results with ice-proximal records emerging from a sedimentological drill core from the Ross Sea (Andrill-2A) that is presented in a companion article. The variability in Antarctic ice volume that we simulate is equivalent to a seawater oxygen isotope signal of 0.52-0.66‰, or a sea level equivalent change of 30-36 m, for a range of atmospheric CO2 between 280 and 500 ppm and a changing astronomical configuration. This result represents a substantial advance in resolving the long-standing model data conflict of Miocene Antarctic ice sheet and sea level variability.

  3. Fibrous Catalyst-Enhanced Acanthamoeba Disinfection by Hydrogen Peroxide.

    Science.gov (United States)

    Kilvington, Simon; Winterton, Lynn

    2017-11-01

    Hydrogen peroxide (H2O2) disinfection systems are contact-lens-patient problem solvers. The current one-step, criterion-standard version has been widely used since the mid-1980s, without any significant improvement. This work identifies a potential next-generation, one-step H2O2, not based on the solution formulation but rather on a case-based peroxide catalyst. One-step H2O2 systems are widely used for contact lens disinfection. However, antimicrobial efficacy can be limited because of the rapid neutralization of the peroxide from the catalytic component of the systems. We studied whether the addition of an iron-containing catalyst bound to a nonfunctional propylene:polyacryonitrile fabric matrix could enhance the antimicrobial efficacy of these one-step H2O2 systems. Bausch + Lomb PeroxiClear and AOSept Plus (both based on 3% H2O2 with a platinum-neutralizing disc) were the test systems. These were tested with and without the presence of the catalyst fabric using Acanthamoeba cysts as the challenge organism. After 6 hours' disinfection, the number of viable cysts was determined. In other studies, the experiments were also conducted with biofilm formed by Stenotrophomonas maltophilia and Elizabethkingia meningoseptica bacteria. Both control systems gave approximately 1-log10 kill of Acanthamoeba cysts compared with 3.0-log10 kill in the presence of the catalyst (P catalyst compared with ≥3.0-log10 kill when it was omitted. In 30 rounds' recurrent usage, the experiments, in which the AOSept Plus system was subjected to 30 rounds of H2O2 neutralization with or without the presence of catalytic fabric, showed no loss in enhanced biocidal efficacy of the material. The catalytic fabric was also shown to not retard or increase the rate of H2O2 neutralization. We have demonstrated the catalyst significantly increases the efficacy of one-step H2O2 disinfection systems using highly resistant Acanthamoeba cysts and bacterial biofilm. Incorporating the catalyst into the

  4. Calcium hypochlorite as a disinfecting additive for dental stone.

    Science.gov (United States)

    Twomey, Jonathan O; Abdelaziz, Khalid M; Combe, Edward C; Anderson, Dwight L

    2003-09-01

    Dental casts come into direct contact with impression materials and other items that are contaminated by saliva and blood from a patient's mouth, leaving the casts susceptible to cross-contamination. Topical methods of disinfecting casts are difficult to control, while immersion methods are potentially destructive. Thus, an additional method to control cross-contamination between patients and laboratory personnel is needed. This study was undertaken in an attempt to develop a dental stone with disinfecting properties and adequate compressive and tensile strengths. Calcium hypochlorite [Ca(OCl)(2)] in aqueous solution in concentrations from 0 to 1.5% was tested as a disinfecting additive to type V dental stone. The compressive and tensile strength properties of the modified stone were measured (MPa) using a universal testing machine at a consistency similar to unmodified stone. Strength data were analyzed by 1-way ANOVA and post hoc Tukey-Kramer procedure (alpha CaviCide, and 3 impressions rinsed in water served as controls. In general, the effect of adding the disinfectant to the stone was a decrease in strength. Exceptions were the dry compressive strength, for which there was a significant increase in strength (P=.048) at 0.5%, and the wet compressive and wet tensile strength, which showed no significant difference between the 1.5% and the control. When Ca(OCl)(2) was added at the concentration 0.5% (2765 ppm available chlorine), the gypsum had acceptable mechanical properties; dry compressive strength was 78.86 +/- 4.12 MPa, and dry tensile strength was 10.64 +/- 1.27 MPa, compared to control values of 67.85 +/- 6.28 and 13.41 +/- 1.24 MPa, respectively. At concentrations of 0.3% and higher (36 1650 ppm of available chlorine), calcium hypochlorite was able to completely inactivate phi29. It is possible to prepare a type V dental stone that contains a disinfectant, has adequate mechanical properties, and will reduce numbers of residual microorganisms. For example

  5. Disinfection efficacy of contact lens care solutions against ocular pathogens.

    Science.gov (United States)

    Miller, M J; Callahan, D E; McGrath, D; Manchester, R; Norton, S E

    2001-01-01

    Three commercially available products labeled as multi-purpose contact lens solutions, one multi-purpose disinfecting solution, and a hydrogen peroxide system were evaluated for antimicrobial activity according to the current International Organization for Standardization (ISO) and the U.S. Food and Drug Administration (FDA) stand-alone procedure for disinfecting products. One multi-purpose solution was selected to assess its antimicrobial activity against two human corneal isolates of Pseudomonas aeruginosa. Products were challenged with bacteria and fungi, and following a specified period, aliquots of inoculated test solution were neutralized and plated on validated recovery media. After incubation the number of viable microorganisms was enumerated and mean log reductions determined. ReNu MultiPlus (Bausch & Lomb, Rochester, NY), AOSEPT (CIBA Vision Corporation, Duluth, GA), and Opti-Free Express with Aldox (Alcon Laboratories, Ft. Worth, TX) were the only lens care products that met the stand-alone criteria for all required microorganisms within their minimum recommended disinfection time. Of these, ReNu MultiPlus provided the greatest overall antimicrobial activity. ReNu MultiPlus demonstrated a significantly higher mean log reduction of Staphylococcus aureus and Serratia marcescens than Opti-Free Express. ReNu MultiPlus also gave a higher mean log reduction of S. aureus and S. marcescens than AOSEPT, and a higher mean log reduction of Candida albicans and Fusarium solani than AOSEPT, Complete Comfort Plus (Allergan, Irivine, CA), and Solo-Care (CIBA Vision Corp.) (at 4 hours). Both Complete Comfort Plus and Solo-Care (at 4 hours) met the primary acceptance criteria for bacteria; however, neither product possessed enough antimicrobial activity to meet the minimum criteria for yeast or mold. ReNu Multiplus was effective against corneal isolates of P. aeruginosa. ReNu MultiPlus, AOSEPT, and Opti-Free Express met the requirements of the stand-alone primary

  6. Video-based instructions for surgical hand disinfection as a replacement for conventional tuition? A randomised, blind comparative study.

    Science.gov (United States)

    Weber, Uwe; Constantinescu, Mihai A; Woermann, Ulrich; Schmitz, Felix; Schnabel, Kai

    2016-01-01

    Various different learning methods are available for planning tuition regarding the introduction to surgical hand disinfection. These learning methods should help to organise and deal with this topic. The use of a video film is an alternative to conventional tuition due to the real presentation possibilities of practical demonstration. This study examines by way of comparison which form of communication is more effective for learning and applying surgical hand disinfection for medical students in their first year of studies: video-based instruction or conventional tuition. A total of 50 first-year medical students were randomly allocated either to the "Conventional Instruction" (CI) study group or to the "Video-based Instruction" (VI) study group. The conventional instruction was carried out by an experienced nurse preceptor/nurse educator for the operating theatre who taught the preparatory measures and the actual procedure in a two-minute lesson. The second group watched a two-minute video sequence with identical content. Afterwards, both groups demonstrated practically the knowledge they had acquired at an individual practical test station. The quality (a) of the preparation and (b) of the procedure as well as (c) the quality of the results was assessed by 6 blind experts using a check list. The acceptability of the respective teaching method was also asked about using a questionnaire. The group performance did not differ either in the preparation (t=-78, pvideo-based instruction achieved a significantly better result. In response to the question as to which of the two learning methods they would prefer, the significant majority (60.4%) of students stated video instruction. In this study, the use of the video-based instruction emerged as the more effective teaching method for learning surgical hand disinfection for medical students and is preferable to conventional instruction. The video instruction is associated with a higher learning effectiveness, efficiency

  7. Genotoxicity of drinking water treated with different disinfectants and effects of disinfection conditions detected by umu-test.

    Science.gov (United States)

    Nie, Xuebiao; Liu, Wenjun; Zhang, Liping; Liu, Qing

    2017-06-01

    The genotoxicity of drinking water treated with 6 disinfection methods and the effects of disinfection conditions were investigated using the umu-test. The pretreatment procedure of samples for the umu-test was optimized for drinking water analysis. The results of the umu-test were in good correlation with those of the Ames-test. The genotoxicity and production of haloacetic acids (HAAs) were the highest for chlorinated samples. UV+chloramination is the safest disinfection method from the aspects of genotoxicity, HAA production and inactivation effects. For chloramination, the effects of the mass ratio of Cl 2 to N of chloramine on genotoxicity were also studied. The changes of genotoxicity were different from those of HAA production, which implied that HAA production cannot represent the genotoxic potential of water. The genotoxicity per chlorine decay of chlorination and chloramination had similar trends, indicating that the reaction of organic matters and chlorine made a great contribution to the genotoxicity. The results of this study are of engineering significance for optimizing the operation of waterworks. Copyright © 2016. Published by Elsevier B.V.

  8. Buckling of Aluminium Sheet Components

    Science.gov (United States)

    Hegadekatte, Vishwanath; Shi, Yihai; Nardini, Dubravko

    Wrinkling is one of the major defects in sheet metal forming processes. It may become a serious obstacle to implementing the forming process and assembling the parts, and may also play a significant role in the wear of the tool. Wrinkling is essentially a local buckling phenomenon that results from compressive stresses (compressive instability) e.g., in the hoop direction for axi-symmetric systems such as beverage cans. Modern beverage can is a highly engineered product with a complex geometry. Therefore in order to understand wrinkling in such a complex system, we have started by studying wrinkling with the Yoshida buckling test. Further, we have studied the buckling of ideal and dented beverage cans under axial loading by laboratory testing. We have modelled the laboratory tests and also the imperfection sensitivity of the two systems using finite element method and the predictions are in qualitative agreement with experimental data.

  9. 46 CFR 232.4 - Balance sheet accounts.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 8 2010-10-01 2010-10-01 false Balance sheet accounts. 232.4 Section 232.4 Shipping... ACTIVITIES UNIFORM FINANCIAL REPORTING REQUIREMENTS Balance Sheet § 232.4 Balance sheet accounts. (a.... (b) Purpose of balance sheet accounts. The balance sheet accounts are intended to disclose the...

  10. Fact Sheets on Pesticides in Schools.

    Science.gov (United States)

    National Coalition against the Misuse of Pesticides, Washington, DC.

    This document consists of a collection of fact sheets about the use of pesticides in schools and how to reduce it. The sheets are: (1) "Alternatives to Using Pesticides in Schools: What Is Integrated Pest Management?"; (2) "Health Effects of 48 Commonly Used Pesticides in Schools"; (3) "The Schooling of State Pesticide…

  11. Balance velocities of the Greenland ice sheet

    DEFF Research Database (Denmark)

    Joughin, I.; Fahnestock, M.; Ekholm, Simon

    1997-01-01

    We present a map of balance velocities for the Greenland ice sheet. The resolution of the underlying DEM, which was derived primarily from radar altimetery data, yields far greater detail than earlier balance velocity estimates for Greenland. The velocity contours reveal in striking detail......, the balance map is useful for ice-sheet modelling, mass balance studies, and field planning....

  12. Advanced friction modeling for sheet metal forming

    NARCIS (Netherlands)

    Hol, J.; Cid Alfaro, M.V.; de Rooij, Matthias B.; Meinders, Vincent T.

    2012-01-01

    The Coulomb friction model is frequently used for sheet metal forming simulations. This model incorporates a constant coefficient of friction and does not take the influence of important parameters such as contact pressure or deformation of the sheet material into account. This article presents a

  13. Advanced friction modeling in sheet metal forming

    NARCIS (Netherlands)

    Hol, J.; Cid Alfaro, M.V.; Meinders, Vincent T.; Huetink, Han

    2011-01-01

    The Coulomb friction model is frequently used for sheet metal forming simulations. This model incorporates a constant coefficient of friction and does not take the influence of important parameters such as contact pressure or deformation of the sheet material into account. This article presents a

  14. Antibubbles and fine cylindrical sheets of air

    NARCIS (Netherlands)

    Beilharz, D.; Guyon, A.; Li, E.Q.; Thoraval, Marie-Jean; Thoroddsen, S.T.

    2015-01-01

    Drops impacting at low velocities onto a pool surface can stretch out thin hemispherical sheets of air between the drop and the pool. These air sheets can remain intact until they reach submicron thicknesses, at which point they rupture to form a myriad of microbubbles. By impacting a

  15. Molding cork sheets to complex shapes

    Science.gov (United States)

    Sharpe, M. H.; Simpson, W. G.; Walker, H. M.

    1977-01-01

    Partially cured cork sheet is easily formed to complex shapes and then final-cured. Temperature and pressure levels required for process depend upon resin system used and final density and strength desired. Sheet can be bonded to surface during final cure, or can be first-formed in mold and bonded to surface in separate step.

  16. Lung Emergencies

    Science.gov (United States)

    ... The Marfan Foundation Marfan & Related Disorders What is Marfan Syndrome? What are Related Disorders? What are the Signs? ... Emergencies Lung Emergencies Surgeries Lung Emergencies People with Marfan syndrome can be at increased risk of sudden lung ...

  17. Peracetic acid (PAA) disinfection of primary, secondary and tertiary treated municipal wastewaters.

    Science.gov (United States)

    Koivunen, J; Heinonen-Tanski, H

    2005-11-01

    The efficiency of peracetic acid (PAA) disinfection against enteric bacteria and viruses in municipal wastewaters was studied in pilot-scale. Disinfection pilot-plant was fed with the primary or secondary effluent of Kuopio municipal wastewater treatment plant or tertiary effluent from the pilot-scale dissolved air flotation (DAF) unit. Disinfectant doses ranged from 2 to 7 mg/l PAA in the secondary and tertiary effluents, and from 5 to 15 mg/l PAA in the primary effluents. Disinfection contact times were 4-27 min. Disinfection of secondary and tertiary effluents with 2-7 mg/l PAA and 27 min contact time achieved around 3 log reductions of total coliforms (TC) and enterococci (EC). PAA disinfection also significantly improved the hygienic quality of the primary effluents: 10-15 mg/l PAA achieved 3-4 log reductions of TC and EC, 5 mg/l PAA resulting in below 2 log reductions. F-RNA coliphages were more resistant against the PAA disinfection and around 1 log reductions of these enteric viruses were typically achieved in the disinfection treatments of the primary, secondary and tertiary effluents. Most of the microbial reductions occurred during the first 4-18 min of contact time, depending on the PAA dose and microorganism. The PAA disinfection efficiency remained relatively constant in the secondary and tertiary effluents, despite of small changes of wastewater quality (COD, SS, turbidity, 253.7 nm transmittance) or temperature. The disinfection efficiency clearly decreased in the primary effluents with substantially higher microbial, organic matter and suspended solids concentrations. The results demonstrated that PAA could be a good alternative disinfection method for elimination of enteric microbes from different wastewaters.

  18. Modern technologies for improving cleaning and disinfection of environmental surfaces in hospitals.

    Science.gov (United States)

    Boyce, John M

    2016-01-01

    Experts agree that careful cleaning and disinfection of environmental surfaces are essential elements of effective infection prevention programs. However, traditional manual cleaning and disinfection practices in hospitals are often suboptimal. This is often due in part to a variety of personnel issues that many Environmental Services departments encounter. Failure to follow manufacturer's recommendations for disinfectant use and lack of antimicrobial activity of some disinfectants against healthcare-associated pathogens may also affect the efficacy of disinfection practices. Improved hydrogen peroxide-based liquid surface disinfectants and a combination product containing peracetic acid and hydrogen peroxide are effective alternatives to disinfectants currently in widespread use, and electrolyzed water (hypochlorous acid) and cold atmospheric pressure plasma show potential for use in hospitals. Creating "self-disinfecting" surfaces by coating medical equipment with metals such as copper or silver, or applying liquid compounds that have persistent antimicrobial activity surfaces are additional strategies that require further investigation. Newer "no-touch" (automated) decontamination technologies include aerosol and vaporized hydrogen peroxide, mobile devices that emit continuous ultraviolet (UV-C) light, a pulsed-xenon UV light system, and use of high-intensity narrow-spectrum (405 nm) light. These "no-touch" technologies have been shown to reduce bacterial contamination of surfaces. A micro-condensation hydrogen peroxide system has been associated in multiple studies with reductions in healthcare-associated colonization or infection, while there is more limited evidence of infection reduction by the pulsed-xenon system. A recently completed prospective, randomized controlled trial of continuous UV-C light should help determine the extent to which this technology can reduce healthcare-associated colonization and infections. In conclusion, continued efforts to

  19. Evaluation of possible use of disinfectant based on chlorine dioxide in dairy plant

    Directory of Open Access Journals (Sweden)

    Rakić-Martinez Mira

    2009-01-01

    Full Text Available Poor sanitation of food contact surfaces has been a contributing factor in food borne disease outbreaks, especially those involving Listeria monocytogenes, Salmonella spp., Escherichia coli, Staphylococcus aureus etc. The objectives of this study were therefore to: 1. Determine the efficiency of a disinfectant based on chlorine dioxide in suspension in a closed system in a dairy plant. 2. Evaluate the possibility of disinfection of working surfaces with a disinfectant based on chlorine dioxide. In order to determine the germicidal effect of the disinfectant based on chlorine dioxide by suspension test (BSEN 1276:1997; the following test organisms were used: Listeria monocytogenes, Proteus mirabilis, Escherichia coli, Bacillus cereus, Staphylococcus aureus and Pseudomonas aeruginosa clinical isolate. The corrosive properties of the disinfectant based on chlorine dioxide were tested by IDF 077:1977 standard. The efficacy of this disinfectant was investigated in a closed system in a dairy plant. Results indicated a 100% reduction of >108 cfu/ml L. monocytogenes, E. coli, Proteus mirabilis, Pseudomonas aeruginosa, S. aureus, viable count after 1 minute of exposure to 100 ppm of the disinfectant based on chlorine dioxide and 400 ppm for Bacillus cereus. In the presence of 2% skim milk and 4 % skim milk concentrations of 200 and 250 ppm resulted in 100% reduction in numbers of the five of six test microorganisms, respectively. The spore former, Bacillus cereus is less susceptible to the disinfectant. Therefore, the efficient concentration for 100% reduction in viable count after 1 minute exposure was 500 ppm. The corrosive properties of the disinfectant were not determined. In the case of closed system disinfection in a dairy plant, reduction in viable count after 15 minute exposure to 100 ppm of disinfectant based on chlorine dioxide ranged from 80 to 100%.

  20. Efficacy of computer-based endoscope cleaning and disinfection using a hospital management information system.

    Science.gov (United States)

    Wang, Caixia; Chen, Yuanyuan; Yang, Feng; Ren, Jie; Yu, Xin; Wang, Jiani; Sun, Siyu

    2016-08-01

    The present study aimed to assess the efficacy of computer-based endoscope cleaning and disinfection using a hospital management information system (HMIS). A total of 2,674 gastroscopes were eligible for inclusion in this study. For the processes of disinfection management, the gastroscopes were randomly divided into 2 groups: gastroscope disinfection HMIS (GD-HMIS) group and manual group. In the GD-HMIS group, an integrated circuit card (IC card) chip was installed to monitor and record endoscope cleaning and disinfection automatically and in real time, whereas the endoscope cleaning and disinfection in the manual group was recorded manually. The overall disinfection progresses for both groups were recorded, and the total operational time was calculated. For the GD-HMIS group, endoscope disinfection HMIS software was successfully developed. The time to complete a single session of cleaning and disinfecting on a gastroscope was 15.6 minutes (range, 14.3-17.2 minutes) for the GD-HMIS group and 21.3 minutes (range, 20.2-23.9 minutes) for the manual group. Failure to record information, such as the identification number of the endoscope, occasionally occurred in the manual group, which affected the accuracy and reliability of manual recording. Computer-based gastroscope cleaning and disinfection using a hospital management information system could monitor the process of gastroscope cleaning and disinfection in real time and improve the accuracy and reliability, thereby ensuring the quality of gastroscope cleaning and disinfection. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  1. Pressure balance between lobe and plasma sheet

    International Nuclear Information System (INIS)

    Baumjohann, W.; Paschmann, G.; Luehr, H.

    1990-01-01

    Using eight months of AMPTE/IRM plasma and magnetic field data, the authors have done a statistical survey on the balance of total (thermal and magnetic) pressure in the Earth's plasma sheet and tail lobe. About 300,000 measurements obtained in the plasma sheet and the lobe were compared for different levels of magnetic activity as well as different distances from the Earth. The data show that lobe and plasma sheet pressure balance very well. Even in the worst case they do not deviate by more than half of the variance in the data itself. Approximately constant total pressure was also seen during a quiet time pass when IRM traversed nearly the whole magnetotail in the vertical direction, from the southern hemisphere lobe through the neutral sheet and into the northern plasma sheet boundary layer

  2. Effectiveness of various cleaning and disinfectant products on Clostridium difficile spores of PCR ribotypes 010, 014 and 027

    NARCIS (Netherlands)

    Kenters, N.; Huijskens, E.G.; Wit, S.C.J. de; Sanders, I.; Rosmalen, J. van; Kuijper, E.J.; Voss, A.

    2017-01-01

    BACKGROUND: In healthcare facilities, Clostridium difficile infections spread by transmission of bacterial spores. Appropriate sporicidal disinfectants are needed to prevent development of clusters and outbreaks. In this study different cleaning/disinfecting wipes and sprays were tested for their

  3. Effectiveness of various cleaning and disinfectant products on Clostridium difficile spores of PCR ribotypes 010, 014 and 027

    NARCIS (Netherlands)

    Kenters, N.; E. Huijskens (Elisabeth); de Wit, S.C.J.; Sanders, I.G.J.M.; J.M. van Rosmalen (Joost); E. Kuijper; Voss, A.

    2017-01-01

    textabstractBackground: In healthcare facilities, Clostridium difficile infections spread by transmission of bacterial spores. Appropriate sporicidal disinfectants are needed to prevent development of clusters and outbreaks. In this study different cleaning/disinfecting wipes and sprays were tested

  4. Comparing peracetic acid and hypochlorite for disinfection of combined sewer overflows: Effects of suspended-solids and pH.

    Science.gov (United States)

    McFadden, M; Loconsole, J; Schockling, A J; Nerenberg, R; Pavissich, J P

    2017-12-01

    Peracetic acid (PAA) is an alternative disinfectant that may be effective for combined sewer overflow (CSO) disinfection, but little is known about the effect of particle size on PAA disinfection efficiency. In this work, PAA and hypochlorite were compared as disinfectants, with a focus on the effect of wastewater particles. Inactivation experiments were conducted on suspended cultures of Escherichia coli and wastewater suspended solids. Tested size fractions included particle diameters disinfection efficiency decreased with increasing solids size. However, solids size had little effect on PAA disinfection. The PAA disinfection efficiency decreased at pH values above 7.5. Live/dead staining revealed that PAA disinfection leaves most cells in a viable but non-culturable condition. Fourier transform infrared spectroscopy (FTIR) analyses suggests that PAA and hypochlorite may inactivate E. coli bacteria by similar mechanisms. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. The efficacy of potassium ferrate as a chemical disinfectant on E. coli, Vibrio cholera, human adenovirus, and Giardia lamblia

    Science.gov (United States)

    Introduction: Drinking water and wastewater go through numerous treatments to remove microorganisms and other contaminants one of many processes along the treatment train is disinfection. There are different ways to disinfect these waters, however to date the most common disinf...

  6. The efficacy of potassium ferrate as a chemical disinfectant on E. coli, Vibrio cholera, human adenovirus, and Giardia lamblia - Abstract

    Science.gov (United States)

    Introduction: Drinking water and wastewater effluents go through numerous treatments to remove microorganisms and other contaminants in the United States. One of many processes along the treatment train is disinfection, and to date the most common disinfectants still remain chemi...

  7. Entrepreneurship, Emerging Technologies, Emerging Markets

    NARCIS (Netherlands)

    Thukral, Inderpreet S.; Von Ehr, James; Walsh, Steven Thomas; Groen, Arend J.; van der Sijde, Peter; Adham, Khairul Akmaliah

    2008-01-01

    Academics and practitioners alike have long understood the benefits, if not the risks, of both emerging markets and emerging technologies.Yet it is only recently that foresighted firms have embraced emerging technologies and emerging markets through entrepreneurial activity. Emerging technologies

  8. Folded Sheet Versus Transparent Sheet Models for Human Symmetry Judgments

    Directory of Open Access Journals (Sweden)

    Jacques Ninio

    2011-07-01

    Full Text Available As a contribution to the mysteries of human symmetry perception, reaction time data were collected on the detection of symmetry or repetition violations, in the context of short term visual memory studies. The histograms for reaction time distributions are rather narrow in the case of symmetry judgments. Their analysis was performed in terms of a simple kinetic model of a mental process in two steps, a slow one for the construction of the representation of the images to be compared, and a fast one, in the 50 ms range, for the decision. There was no need for an additional ‘mental rotation’ step. Symmetry seems to facilitate the construction step. I also present here original stimuli showing a color equalization effect across a symmetry axis, and its counterpart in periodic patterns. According to a “folded sheet model”, when a shape is perceived, the brain automatically constructs a mirror-image representation of the shape. Based in part on the reaction time analysis, I present here an alternative “transparent sheet” model in which the brain constructs a single representation, which can be accessed from two sides, thus generating simultaneously a pattern and its mirror-symmetric partner. Filtering processes, implied by current models of symmetry perception could intervene at an early stage, by nucleating the propagation of similar perceptual groupings in the two symmetric images.

  9. Poorly processed reusable surface disinfection tissue dispensers may be a source of infection.

    Science.gov (United States)

    Kampf, Günter; Degenhardt, Stina; Lackner, Sibylle; Jesse, Katrin; von Baum, Heike; Ostermeyer, Christiane

    2014-01-21

    Reusable surface disinfectant tissue dispensers are used in hospitals in many countries because they allow immediate access to pre-soaked tissues for targeted surface decontamination. On the other hand disinfectant solutions with some active ingredients may get contaminated and cause outbreaks. We determined the frequency of contaminated surface disinfectant solutions in reusable dispensers and the ability of isolates to multiply in different formulations. Reusable tissue dispensers with different surface disinfectants were randomly collected from healthcare facilities. Solutions were investigated for bacterial contamination. The efficacy of two surface disinfectants was determined in suspension tests against two isolated species directly from a contaminated solution or after 5 passages without selection pressure in triplicate. Freshly prepared use solutions were contaminated to determine survival of isolates. 66 dispensers containing disinfectant solutions with surface-active ingredients were collected in 15 healthcare facilities. 28 dispensers from nine healthcare facilities were contaminated with approximately 107 cells per mL of Achromobacter species 3 (9 hospitals), Achromobacter xylosoxidans or Serratia marcescens (1 hospital each). In none of the hospitals dispenser processing had been adequately performed. Isolates regained susceptibility to the disinfectants after five passages without selection pressure but were still able to multiply in different formulations from different manufacturers at room temperature within 7 days. Neglecting adequate processing of surface disinfectant dispensers has contributed to frequent and heavy contamination of use-solutions based on surface active ingredients. Tissue dispenser processing should be taken seriously in clinical practice.

  10. Photocatalytic disinfection of spoilage bacteria Pseudomonas fluorescens and Macrococcus caseolyticus by nano-TiO2

    Science.gov (United States)

    Photocatalytic disinfection of spoilage bacteria gram-negative (G-) P. fluorescens and gram-positive (G+) M. caseolyticus by nano-TiO2 under different experimental conditions and the disinfection mechanism were investigated. The experimental conditions included the initial bacterial populations, nan...

  11. Irradiation as an alternative for disinfection of domestic waste in the Canadian Arctic

    International Nuclear Information System (INIS)

    1981-01-01

    This study evaluated the technical and economic feasibility of various methods for disinfecting wastewater in the Canadian Arctic with specific reference to gamma radiation. More conventional disinfection practices, such as chlorination, chlorination-dechlorination, and ozonation were compared to gamma radiation along with ultraviolet irradiation and lime disinfection. The quality of lagoon effluent, highly diluted (weak) sewage, holding tank wastes and honey-bag wastes, which are the typical waste types found in northern communities, was established from data available in the literature. Further literature reviews were undertaken to establish a data base for design and effectiveness of disinfection systems operated in cold climates. Capital and operating costs for all technically feasible disinfection process alternates were estimated based on historical cost data adjusted to 1977 for the construction and instalation of similar systems in the north. The costs of equipment, chemicals, fuel and electrical power were obtained from suppliers. The environmental impact of each of the disinfection processes was reviewed with emphasis on gamma irradiation. Safety and health aspects were also considered. The study concluded that gamma irradiation was capable of providing safe, reliable disinfection for concentrated honey-bag and holding wastes. Pilot-scale testing was recommended prior to construction of full-scale disinfection facilities. For lagoon effluents and weak sewage, gamma irradiation was not cost competitive with other alternates; rather chlorination-dechlorination was found to be the most cost-effective and environmentally acceptable alternative

  12. Fungicidal effect of 15 disinfectants against 24 fungal contaminants commonly found in bread and cheese manufacturing

    DEFF Research Database (Denmark)

    Bundgaard-Nielsen, Kirsten; Nielsen, Per Væggemose

    1996-01-01

    Resistance of 19 mold- and 6 yeast- species against 15 commercial disinfectants was investigated by a suspension-method in which the fungicidal effect and germination time were determined at 20 °C. Disinfectants containing 0.5 % dodecyldiethylentriaminacetic acid, 10 g/l chloramine-T, 2.0 % forma...

  13. Determining Exposure Factors of Anti-Fogging, Dye, Disinfectant, Repellent, and Preservative Products in Korea.

    Science.gov (United States)

    Lee, Daeyeop; Kim, Joo-Hyon; Kim, Taksoo; Yoon, Hyojung; Jo, Areum; Lee, Byeongwoo; Lim, Hyunwoo; Kim, Pilje; Seo, Jungkwan

    2018-01-30

    Reliable exposure factors are essential to determine health risks posed by chemicals in consumer products. We analyzed five risk-concerned product categories (anti-fogging, dye, disinfectant, repellent, and preservative products) for 13 products (three car anti-fogging products, a lens anti-fogging product, two car dye products, two drain disinfectants, an air conditioner disinfectant, a chlorine-based disinfectant, a fabric repellent, an insect repellent for food, and a wood preservative) considered to be of high risk in order to determine exposure factors via web surveys and estimation of amount of product. Among the 3000 participants (1482 (49%) men) aged ≥19 years, drain disinfectants were used most frequently (38.2%); the rate of usage of the other products ranged between 1.1-24.0%. The usage rates for the consumer products differed by sex, age, income, and education. Some consumer products such as car and lens anti-fogging products, chlorine-based disinfectants, fabric repellents, and drain disinfectants were regularly used more than once a month, while car dye products, air conditioner disinfectants, insect repellents for food, and wood preservatives were not regularly used owing to the specific product purposes and seasonal needs. Our results could be used for managing or controlling chemical substances in consumer products and conducting accurate exposure assessments.

  14. Chloraminated Concentrated Drinking Water for Disinfection Byproduct Mixtures Research: Evaluating Free Chlorine Contact Times

    Science.gov (United States)

    Complex mixtures of disinfection by-products (DBPs) are formed when the disinfectant oxidizes constituents (e.g., natural organic matter (NOM) and organic pollutants) present in the source water. Since 1974, over 600 DBPs have been identified in drinking water, yet a large portio...

  15. Chloramination of Concentrated Drinking Water for Disinfection Byproduct Mixtures Creation- Indianapolis

    Science.gov (United States)

    Complex mixtures of disinfection by-products (DBPs) are formed when the disinfectant oxidizes constituents (e.g., natural organic matter (NOM) and organic pollutants) found in the source water. Since 1974, over 600 DBPs have been identified in drinking water. Despite intense iden...

  16. Chloramination of Concentrated Drinking Water: Evaluation of Disinfection Byproduct Formation and Dosing Scenarios - Portland

    Science.gov (United States)

    Complex mixtures of disinfection by-products (DBPs) are formed when the disinfectant oxidizes constituents (e.g., natural organic matter (NOM) and organic pollutants) found in the source water. Since 1974, over 600 DBPs have been identified in drinking water. Despite intense iden...

  17. Innovative Approach to Validation of Ultraviolet (UV) Reactors for Disinfection in Drinking Water Systems - presentation

    Science.gov (United States)

    UV disinfection is an effective process for inactivating many microbial pathogens found in source waters with the potential as stand-alone treatment or in combination with other disinfectants. For surface and groundwater sourced drinking water applications, the U.S. Environmental...

  18. Two-Center Evaluation of Disinfectant Efficacy against Ebola Virus in Clinical and Laboratory Matrices

    Science.gov (United States)

    Smither, Sophie J.; Eastaugh, Lin; Filone, Claire Marie; Freeburger, Denise; Herzog, Artemas; Lever, M. Stephen; Miller, David M.; Mitzel, Dana; Noah, James W.; Reddick-Elick, Mary S.; Reese, Amy; Schuit, Michael; Wlazlowski, Carly B.; Hevey, Michael

    2018-01-01

    Ebola virus (EBOV) in body fluids poses risk for virus transmission. However, there are limited experimental data for such matrices on the disinfectant efficacy against EBOV. We evaluated the effectiveness of disinfectants against EBOV in blood on surfaces. Only 5% peracetic acid consistently reduced EBOV titers in dried blood to the assay limit of quantification. PMID:29261093

  19. Comparing Peracetic Acid with Sodium Hypochlorite for Disinfection of Combined Sewer Overflows

    Science.gov (United States)

    This cooperative research and development agreement between U.S. EPA, Solvay, MSDGC, and CB&I is evaluating the potential of PAA for disinfection of Muddy Creek CSO wastewater and comparing that with sodium hypochlorite disinfection. This presentation will document the effective...

  20. Bench-Scale Evaluation of Peracetic Acid and Twin Oxide ™ as Disinfectants in Drinking Water

    Science.gov (United States)

    Chlorine is widely used as an inexpensive and potent disinfectant in the United States for drinking water. However, chlorine has the potential for forming carcinogenic and mutagenic disinfection by-products (DBPs). In this study, bench scale experiments were conducted at the U.S...

  1. High-Rate Disinfection Techniques for Combined Sewer Overflow (Proceedings Paper)

    Science.gov (United States)

    This paper presents high-rate disinfection technologies for combined sewer overflow (CSO). The high-rate disinfection technologies of interest are: chlorination/dechlorination, ultraviolet light irradiation (UV), chlorine dioxide (ClO2 ), ozone (O3), peracetic acid (CH3COOOH ), a...

  2. Experience of using heat citric acid disinfection method in central dialysis fluid delivery system.

    Science.gov (United States)

    Sakuma, Koji; Uchiumi, Nobuko; Sato, Sumihiko; Aida, Nobuhiko; Ishimatsu, Taketo; Igoshi, Tadaaki; Kodama, Yoshihiro; Hotta, Hiroyuki

    2010-09-01

    We applied the heat citric acid disinfection method in the main part of the central dialysis fluid delivery system (MPCDDS), which consists of a multiple-patient dialysis fluid supply unit, dialysis console units, and dialysis fluid piping. This disinfection method has been used for single-patient dialysis machines, but this is the first trial in the MPCDDS. We examined, by points of safety and disinfection effect, whether this disinfection method is comparable to conventional disinfection methods in Japan. The conventional disinfection method is a combination of two disinfectants, sodium hypochlorite and acetic acid, used separately for protein removal and decalcification. Consequently, total microbial counts and endotoxin concentrations fully satisfied the microbiological requirements for standard dialysis fluid of ISO 11663. From our results and discussion, this heat citric acid disinfection method is proved to be safe and reliable for MPCDDS. However, to satisfy the microbiological requirements for ultrapure dialysis fluid, further consideration for this method in MPCDDS including the reverse osmosis device composition and piping is necessary.

  3. Comparative transcriptome and phenotype analysis of Bacillus cereus in response to disinfectant treatments

    NARCIS (Netherlands)

    Ceragioli, Mara; Mols, J.M.; Moezelaar, Roy; Ghelardi, Emilia; Senesi, Sonia; Abee, Tjakko

    2010-01-01

    Antimicrobial chemicals are widely applied to clean and disinfect food-contacting surfaces. However, the cellular response of bacteria, such as Bacillus cereus, to various disinfectants is unclear. In this study, the physiological and genome-wide transcriptional responses of B. cereus ATCC 14579

  4. Comparative transcriptomic and phenotypic analysis of the responses of Bacillus cereus to various disinfectant treatments

    NARCIS (Netherlands)

    Ceragioli, M.; Mols, J.M.; Moezelaar, R.; Ghelardi, E.; Senesi, S.; Abee, T.

    2010-01-01

    Antimicrobial chemicals are widely applied to clean and disinfect food-contacting surfaces. However, the cellular response of bacteria to various disinfectants is unclear. In this study, the physiological and genome-wide transcriptional responses of Bacillus cereus ATCC 14579 exposed to four

  5. A microbiological evaluation of level of disinfection for flexible cystoscopes protected by disposable endosheaths

    DEFF Research Database (Denmark)

    Jørgensen, Peter Hjorth; Slotsbjerg, Torsten; Westh, Henrik

    2013-01-01

    Flexible cystoscopy is used in urological outpatient departments for diagnostic cystoscopy of bladder cancer and requires a high-level disinfection between each patient. The purpose of this study was to make a microbiological post disinfection efficacy assessment of flexible cystoscopes (FC) using...

  6. Industrial disinfectants do not select for resistance in Listeria monocytogenes following long term exposure

    DEFF Research Database (Denmark)

    Kastbjerg, Vicky Gaedt; Gram, Lone

    2012-01-01

    or tolerance would evolve in L. monocytogenes under continued selection in three industrial disinfectants. L. monocytogenes EGD was exposed to Desinfect CL (hypochlorite) and Incimaxx DES (peracedic acid and hydrogen peroxide) for several hundred generations. This caused no increase in the minimal inhibitory......, and that the disinfectants are still efficient for controlling microorganisms such as L. monocytogenes....

  7. Development of a Standard Test to Assess the Resistance of Staphylococcus aureus Biofilm Cells to Disinfectants

    NARCIS (Netherlands)

    Luppens, S.B.I.; Reij, M.W.; Heijden, van der R.W.; Rombouts, F.M.; Abee, T.

    2002-01-01

    A standardized disinfectant test for Staphylococcus aureus cells in biofilms was developed. Two disinfectants, the membrane-active compound benzalkonium chloride (BAC) and the oxidizing agent sodium hypochlorite, were used to evaluate the biofilm test. S. aureus formed biofilms on glass, stainless

  8. CONTROL OF MICROBIAL CONTAMINANTS AND DISINFECTION BY-PRODUCTS (DBPS): COST AND PERFORMANCE

    Science.gov (United States)

    The USEPA is in the process of developing a sophisticated regulatory strategy in an attempt to balance the complex trade-offs in risks associated with controlling disinfectants and disinfection by-products (D/DBPs) in drinking water. EPA first attempted to control DBPs in 1974, w...

  9. 76 FR 39092 - Agency Information Collection Activities; Proposed Collection; Comment Request; Disinfectants...

    Science.gov (United States)

    2011-07-05

    ... Office of Management and Budget (OMB). The ICRs scheduled to expire are Disinfectants/Disinfection...) enhance the quality, utility, and clarity of the information to be collected; and (iv) minimize the burden...-community water systems such as restaurants and campgrounds. What should I consider when I prepare my...

  10. Reducing viral contamination from finger pads: handwashing is more effective than alcohol-based hand disinfectants

    NARCIS (Netherlands)

    Tuladhar, E.; Hazeleger, W.C.; Koopmans, M.; Zwietering, M.H.; Duizer, E.

    2015-01-01

    Background - Hand hygiene is important for interrupting transmission of viruses through hands. Effectiveness of alcohol-based hand disinfectant has been shown for bacteria but their effectiveness in reducing transmission of viruses is ambiguous. Aim - To test efficacy of alcohol hand disinfectant

  11. 9 CFR 71.12 - Sodium orthophenylphenate as permitted disinfectant for premises infected with tuberculosis.

    Science.gov (United States)

    2010-01-01

    ... disinfectant for premises infected with tuberculosis. 71.12 Section 71.12 Animals and Animal Products ANIMAL... disinfectant for premises infected with tuberculosis. (a) A permitted brand of sodium orthophenylphenate in a proportion of at least one pound to 12 gallons of water is permitted in tuberculosis eradication work for...

  12. Does improving surface cleaning and disinfection reduce health care-associated infections?

    Science.gov (United States)

    Donskey, Curtis J

    2013-05-01

    Contaminated environmental surfaces provide an important potential source for transmission of health care-associated pathogens. In recent years, a variety of interventions have been shown to be effective in improving cleaning and disinfection of surfaces. This review examines the evidence that improving environmental disinfection can reduce health care-associated infections. Published by Mosby, Inc.

  13. Evaluation of 5 cleaning and disinfection methods for nets used to collect zebrafish (Danio rerio).

    Science.gov (United States)

    Collymore, Chereen; Porelli, Gina; Lieggi, Christine; Lipman, Neil S

    2014-11-01

    Few standardized methods of cleaning and disinfecting equipment in zebrafish facilities have been published, even though the effectiveness of these procedures is vital to preventing the transmission of pathogenic organisms. Four chemical disinfectants and rinsing with municipal tap water were evaluated for their ability to disinfect nets used to capture zebrafish. The disinfectants included benzalkonium chloride+methylene blue, sodium hypochlorite, chlorine dioxide, and potassium peroxymonosulfate+sodium chloride for a soak time of 5 or 30 min. Disinfection effectiveness was evaluated by using an ATP-based system that measured the reduction in absolute number and percentage of relative light units. In addition, nets were cultured aerobically on blood and MacConkey agar plates to determine the number of bacteria remaining after disinfection procedures. Soaking nets in sodium hypochlorite for 30 min and in potassium peroxymonosulfate+sodium chloride for 5 or 30 min were effective means of disinfection, according to at least 90% reduction in the number of relative light units and no bacterial growth after cleaning. These results will aid facility managers, veterinarians and investigators in selecting net cleaning and disinfection protocols.

  14. Endoscope disinfection and its pitfalls--requirement for retrograde surveillance cultures.

    NARCIS (Netherlands)

    Buss, A.J.; Been, M.H.; Borgers, R.P.; Stokroos, I.; Melchers, W.J.G.; Peters, F.T.; Limburg, A.J.; Degener, J.E.

    2008-01-01

    BACKGROUND AND STUDY AIMS: Several endoscopy-related outbreaks of infection have been reported in recent years. For early recognition of inadequate disinfection of endoscopes we designed a microbiological surveillance system to evaluate the efficacy of the cleaning and disinfection procedure, and to

  15. Some factors influencing the effective use of disinfectants and cleaning agents

    Directory of Open Access Journals (Sweden)

    W.P. Kortenbout

    1982-09-01

    Full Text Available Disinfection means the freeing of an article from some or all of its burden of live pathogenic microorganisms which might cause infection during its use. The term is a relative one and disinfection may be described as being partially or highly effective according to the proportion of pathogenic organisms killed or removed.

  16. Microbial quality of swimming pool water with treatment without disinfection, with ultrafiltration, with UV-based treatment and with chlorination

    NARCIS (Netherlands)

    Keuten, M.G.A.; Peters, M.C.F.M.; van Dijk, J.C.; van Loosdrecht, Mark C.M.; Rietveld, L.C.

    2017-01-01

    Swimming pools are traditionally disinfected with a residual disinfectant such as sodium hypochlorite. Nowadays, swimming water without a residual disinfectant is increasingly popular, as can be seen by the growing number of (natural) swimming ponds (Weilandt 2015), but health risks for bathers do

  17. 9 CFR 309.7 - Livestock affected with anthrax; cleaning and disinfection of infected livestock pens and driveways.

    Science.gov (United States)

    2010-01-01

    ...; cleaning and disinfection of infected livestock pens and driveways. 309.7 Section 309.7 Animals and Animal... INSPECTION § 309.7 Livestock affected with anthrax; cleaning and disinfection of infected livestock pens and... followed immediately by a thorough disinfection of the exposed premises by soaking the ground, fences...

  18. Removal of Crotamiton from Reverse Osmosis Concentrate by a TiO2/Zeolite Composite Sheet

    Directory of Open Access Journals (Sweden)

    Qun Xiang

    2017-07-01

    Full Text Available Reverse osmosis (RO concentrate from wastewater reuse facilities contains concentrated emerging pollutants, such as pharmaceuticals. In this research, a paper-like composite sheet consisting of titanium dioxide (TiO2 and zeolite was synthesized, and removal of the antipruritic agent crotamiton from RO concentrate was studied using the TiO2/zeolite composite sheet. The RO concentrate was obtained from a pilot-scale municipal secondary effluent reclamation plant. Effective immobilization of the two powders in the sheet made it easy to handle and to separate the photocatalyst and adsorbent from purified water. The TiO2/zeolite composite sheet showed excellent performance for crotamiton adsorption without obvious inhibition by other components in the RO concentrate. With ultraviolet irradiation, crotamiton was simultaneously removed through adsorption and photocatalysis. The photocatalytic decomposition of crotamiton in the RO concentrate was significantly inhibited by the water matrix at high initial crotamiton concentrations, whereas rapid decomposition was achieved at low initial crotamiton concentrations. The major degradation intermediates were also adsorbed by the composite sheet. This result provides a promising method of mitigating secondary pollution caused by the harmful intermediates produced during advanced oxidation processes. The cyclic use of the HSZ-385/P25 composite sheet indicated the feasibility of continuously removing crotamiton from RO concentrate.

  19. Comparison of electrochemical method with ozonation, chlorination and monochloramination in drinking water disinfection

    Energy Technology Data Exchange (ETDEWEB)

    Li Hongna, E-mail: lihongna@gmail.com [Department of Environmental Engineering, Peking University, Key Laboratory of Water and Sediment Sciences, Ministry of Education, Beijing 100871 (China); Zhu Xiuping [Department of Environmental Engineering, Peking University, Key Laboratory of Water and Sediment Sciences, Ministry of Education, Beijing 100871 (China); Ni Jinren, E-mail: nijinren@iee.pku.edu.cn [Department of Environmental Engineering, Peking University, Key Laboratory of Water and Sediment Sciences, Ministry of Education, Beijing 100871 (China)

    2011-11-30

    Highlights: > Electrochemical, O{sub 3}, NaClO and NH{sub 2}Cl were compared at respective optimal condition. > Disinfection efficacy was similar for different bacteria in electrolysis. > Harsh Bacillus was inactivated more difficult in O{sub 3}, NaClO and NH{sub 2}Cl system. > Efficient disinfection of electrolysis was attributed to nonselectivity of {center_dot}OH. > Cell surface damage was more obvious in electrochemical process than the others. - Abstract: Electrochemical process in chloride-free electrolytes was proved to be powerful in disinfection due to the strong oxidants produced in the electrolysis and no formation of disinfection byproducts (DBPs). In this study, disinfection experiments were conducted by electrochemical treatment compared with ordinary and advanced methods (ozonation, chlorination and monochloramination), with Escherichia coli (E. coli) K-12, Staphylococcus aureus (S. aureus) A106, Bacillus subtilis (BST) and an isolated Bacillus as the representative microorganisms. Firstly, factor tests were performed on E. coli to obtain the optimal conditions of the four disinfection procedures. At their respective optimal condition, CT (concentration of disinfectant x contact time) value of a 4-log E. coli inactivation was 33.5, 1440, 1575, 1674 mg min L{sup -1} for electrochemical process, ozonation, chlorination and monochloramination, respectively. It was demonstrated that the disinfection availability was in the following order: electrochemical process > ozonation > chlorination > monochloramination, which could be attributed to the hydroxyl radical generated in the electrolysis, with strong oxidizing ability and non-selectivity compared with the other three disinfectants. Moreover, the disinfection efficacy of the four disinfection procedures was compared for four different bacteria. It was found that the disinfection efficacy was similar for the selected four bacteria in electrochemical process, while in the other three treatments

  20. Comparison of electrochemical method with ozonation, chlorination and monochloramination in drinking water disinfection

    International Nuclear Information System (INIS)

    Li Hongna; Zhu Xiuping; Ni Jinren

    2011-01-01

    Highlights: → Electrochemical, O 3 , NaClO and NH 2 Cl were compared at respective optimal condition. → Disinfection efficacy was similar for different bacteria in electrolysis. → Harsh Bacillus was inactivated more difficult in O 3 , NaClO and NH 2 Cl system. → Efficient disinfection of electrolysis was attributed to nonselectivity of ·OH. → Cell surface damage was more obvious in electrochemical process than the others. - Abstract: Electrochemical process in chloride-free electrolytes was proved to be powerful in disinfection due to the strong oxidants produced in the electrolysis and no formation of disinfection byproducts (DBPs). In this study, disinfection experiments were conducted by electrochemical treatment compared with ordinary and advanced methods (ozonation, chlorination and monochloramination), with Escherichia coli (E. coli) K-12, Staphylococcus aureus (S. aureus) A106, Bacillus subtilis (BST) and an isolated Bacillus as the representative microorganisms. Firstly, factor tests were performed on E. coli to obtain the optimal conditions of the four disinfection procedures. At their respective optimal condition, CT (concentration of disinfectant x contact time) value of a 4-log E. coli inactivation was 33.5, 1440, 1575, 1674 mg min L -1 for electrochemical process, ozonation, chlorination and monochloramination, respectively. It was demonstrated that the disinfection availability was in the following order: electrochemical process > ozonation > chlorination > monochloramination, which could be attributed to the hydroxyl radical generated in the electrolysis, with strong oxidizing ability and non-selectivity compared with the other three disinfectants. Moreover, the disinfection efficacy of the four disinfection procedures was compared for four different bacteria. It was found that the disinfection efficacy was similar for the selected four bacteria in electrochemical process, while in the other three treatments inactivation of the two

  1. Tube sheet design for PFBR steam generator

    International Nuclear Information System (INIS)

    Chellapandi, P.; Chetal, S.C.; Bhoje, S.B.

    1991-01-01

    Top and bottom tube sheets of PFBR Steam Generators have been analysed with 3D and axisymmetric models using CASTEM Programs. Analysis indicates that the effects of piping reactions at the inlet/outlet nozzles on the primary stresses in the tube sheets are negligible and the asymmetricity of the deformation pattern introduced in the tube sheet by the presence of inlet/outlet and manhole nozzles is insignificant. The minimum tube sheet thicknesses for evaporator and reheater are 135 mm and 75 mm respectively. Further analysis has indicated the minimum fillet radius at the junction of tube sheet and dished end should be 20 mm. Simplified methodology has been developed to arrive at the number of thermal baffles required to protect the tube sheet against fatigue damage due to thermal transient. This method has been applied to PFBR steam generators to determine the required number of thermal baffles. For protecting the bottom tube sheet of evaporator against the thermal shock due to feed water and secondary pump trip, one thermal shield is found to be sufficient. Further analysis is required to decide upon the actual number to take care of the severe thermal transient, following the event of sudden dumping of water/steam, immediately after the sodium-water reaction. (author)

  2. Peracetic acid disinfection: a feasible alternative to wastewater chlorination.

    Science.gov (United States)

    Rossi, S; Antonelli, M; Mezzanotte, V; Nurizzo, C

    2007-04-01

    The paper summarizes the results of a bench-scale study to evaluate the feasibility of using peracetic acid (PAA) as a substitute for sodium hypochlorite both for discharge into surface water and for agricultural reuse. Trials were carried out with increasing doses (1, 2, 3, 5, 10, and 15 mg/L) and contact times (6, 12, 18, 36, 42, and 54 minutes) to study disinfectant decay and bacterial removal and regrowth, using fecal coliform and Escherichia coli (E. coli) as process efficiency indicators. Peracetic acid decay kinetics was evaluated in tap water and wastewater; in both cases, PAA decays according to first-order kinetics with respect to time, and a correlation was found between PAA oxidative initial consumption and wastewater characteristics. The PAA disinfection efficiency was correlated with operating parameters (active concentration and contact time), testing different kinetic models. Two data groups displaying a different behavior on the basis of initial active concentration ranges (1 to 2 mg/L and 5 to 15 mg/L, respectively) can be outlined. Both groups had a "tailing-off" inactivation curve with respect to time, but the second one showed a greater inactivation rate. Moreover, the effect of contact time was greater at the lower doses. Hom's model, used separately for the two data groups, was found to best fit experimental data, and the disinfectant active concentration appears to be the main factor affecting log-survival ratios. Moreover, the S-model better explains the initial resistance of E. coli, especially at low active concentrations (< 2 mg/L) and short contact times (< 12 minutes). Microbial counts, performed by both traditional methods and flow cytometry, immediately and 5 hours after sample collection (both with or without residual PAA inactivation), showed that no appreciable regrowth took place after 5 hours, neither for coliform group bacteria, nor for total heterotrophic bacteria.

  3. Enhancing blood donor skin disinfection using natural oils.

    Science.gov (United States)

    Alabdullatif, Meshari; Boujezza, Imen; Mekni, Mohamed; Taha, Mariam; Kumaran, Dilini; Yi, Qi-Long; Landoulsi, Ahmed; Ramirez-Arcos, Sandra

    2017-12-01

    Effective donor skin disinfection is essential in preventing bacterial contamination of blood components with skin flora bacteria like Staphylococcus epidermidis. Cell aggregates of S. epidermidis (biofilms) are found on the skin and are resistant to the commonly used donor skin disinfectants chlorhexidine-gluconate and isopropyl alcohol. It has been demonstrated that essential oils synergistically enhance the antibacterial activity of chlorhexidine-gluconate. The objective of this study was to test plant-extracted essential oils in combination with chlorhexidine-gluconate or chlorhexidine-gluconate plus isopropyl alcohol for their ability to eliminate S. epidermidis biofilms. The composition of oils extracted from Artemisia herba-alba, Lavandula multifida, Origanum marjoram, Rosmarinus officinalis, and Thymus capitatus was analyzed using gas chromatography-mass spectrometry. A rabbit model was used to assess skin irritation caused by the oils. In addition, the anti-biofilm activity of the oils used alone or in combination with chlorhexidine-gluconate or chlorhexidine-gluconate plus isopropyl alcohol was tested against S. epidermidis biofilms. Essential oil concentrations 10%, 20%, and 30% were chosen for anti-biofilm assays, because skin irritation was observed at concentrations greater than 30%. All oils except for O. marjoram had anti-biofilm activity at these three concentrations. L. multifida synergistically enhanced the anti-biofilm activity of chlorhexidine-gluconate and resulted in the highest anti-biofilm activity observed when combined with chlorhexidine-gluconate plus isopropyl alcohol. Gas chromatography-mass spectrometry revealed that the main component contributing to the activity of L. multifida oil was a natural terpene alcohol called linalool. The anti-biofilm activity of chlorhexidine-gluconate plus isopropyl alcohol can be greatly enhanced by L. multifida oil or linalool. Therefore, these components could potentially be used to improve blood

  4. Activity of disinfectants and biofilm production of Corynebacterium pseudotuberculosis

    Directory of Open Access Journals (Sweden)

    Maria da C.A. Sá

    2013-11-01

    Full Text Available To verify the occurrence of caseous lymphadenitis in sheep and goats on farms of Pernambuco, Brazil, and in animals slaughtered in two Brazilian cities (Petrolina/PE and Juazeiro/BA, and to characterize the susceptibility profile of Corynebacterium pseudotuberculosis to disinfectants and antimicrobials, and its relationship with biofilm production were the objectives of this study. 398 samples were tested for sensitivity to antimicrobial drugs, disinfectants, and biofilm production. Among the 108 samples collected on the properties, 75% were positive for C. pseudotuberculosis. Slaughterhouse samples indicated an occurrence of caseous lymphadenitis in 15.66% and 6.31% for animals slaughtered in Petrolina and Juazeiro respectively. With respect to antimicrobials, the sensitivity obtained was 100% for florfenicol and tetracycline; 99.25% for enrofloxacin, ciprofloxacin and lincomycin; 98.99% for cephalothin; 98.74% for norfloxacin and sulfazotrim; 97.74% for gentamicin; 94.22% for ampicillin; 91.71% for amoxicillin; 91.21% for penicillin G; 89.19% for neomycin and 0% for novobiocin. In analyzes with disinfectants, the efficiency for chlorhexidine was 100%, 97.20% for quaternary ammonium, 87.40% for chlorine and 84.40% for iodine. 75% of the isolates were weak or non-biofilm producers. For the consolidated biofilm, found that iodine decreased biofilm formation in 13 isolates and quaternary ammonia in 11 isolates. The reduction of the biofilm formation was observed for iodine and quaternary ammonium in consolidated biofilm formation in 33% and 28% of the isolates, respectively. The results of this study highlight the importance of establishing measures to prevent and control the disease.

  5. Is pomegranate peels infusion effective for disinfection of toothbrushes?

    Directory of Open Access Journals (Sweden)

    Priscila Lima de Luna FREIRE

    Full Text Available Abstract Introduction Methods of decontamination or sanitization of toothbrushes have been questioned. Objective This study assessed the effectiveness of pomegranate peels infusion as a disinfectant of toothbrushes against Streptococcus mutans. Material and method A sample of 16 schoolchildren aged between 7 and 9 years performed brushing 5 days/week, with a careful brushing once a day. After each day of brushing, the toothbrushes were washed and sprayed with one disinfectant solution. This procedure was repeated for 4 weeks using one of the different solutions per week: distilled water (G1; negative control, pomegranate (Punica granatum Linn peels infusion (G2, 1% sodium hypochlorite (G3 and 0.12% chlorhexidine digluconate (G4. After the fifth day, toothbrushes were collected for laboratory analysis. Toothbrushes heads were subjected to agitation in saline dilution of 10–1, 10–2,10–3, and 25 μL of each dilution were seeded in mitis salivarius agar culture medium for S. mutans colony-forming unit (CFU counting. One calibrated examiner (Kappa = 0.91 performed the CFU (mL–1 × 104 counts. Kruskal-Wallis and Dunn Multiple Comparison tests were used at a significance level of 5%. Result G1 presented the highest number of CFU (3.9 ± 8.4, followed by G2 (3.2 ± 4.0. No S. mutans growth was observed in G3 and G4. There was no statistically significant difference between G1 and G2 and between G3 and G4 (p>0.05. Conclusion Pomegranate infusion was completely ineffective for the disinfection of toothbrushes against S. mutans when compared with 1% sodium hypochlorite and 0.12% chlorhexidine digluconate solutions.

  6. Efficacy and toxicity of iodine disinfection of Atlantic salmon eggs

    Science.gov (United States)

    Chalupnicki, M.A.; Ketola, H.G.; Starliper, C.E.; Gallagher, D.

    2011-01-01

    Recent interest in the restoration of Atlantic salmon Salmo salar in the Great Lakes has given rise to new culture techniques and management programs designed to reduce pathogen transmission while stabilizing and enhancing wild populations. We examined the toxicity of iodine to Atlantic salmon eggs and its effectiveness as a disinfectant against bacteria on egg surfaces. We spawned and fertilized eight gravid Atlantic salmon from Cayuga Lake, New York, and exposed their eggs to 10 concentrations of iodine (5, 10, 50, 75, 100, 500, 750, 1,000, 5,000, and 7,500 mg/L) for 30 min during water hardening. An additional subsample of unfertilized eggs was also exposed to some of the same concentrations of iodine (5, 10, 50, 75, and 100 mg/L) to determine the efficiency of disinfection. Viable eggs were only obtained from four females. Survival of eggs to the eyed stage and hatch tended to be reduced at iodine concentrations of 50 and 75 mg/L and was significantly reduced at concentrations of 100 mg/L iodine or more. We calculated the concentrations of iodine that killed 50% of the Atlantic salmon eggs at eye-up and hatch to be 175 and 85 mg/L, respectively. Aeromonas veronii, A. schubertii, A. hydrophila, A. caviae, Plesiomonas shiggeloides, and Citrobacter spp. were the predominant bacteria present on the surface of green eggs and were significantly reduced by an iodine immersion. The use of iodine as a disinfectant on Atlantic salmon eggs was effective at low concentrations (50–75 mg/L), for which toxicity to Atlantic salmon was minimal.

  7. [Surface disinfection in the context of infection prevention in intensive care units].

    Science.gov (United States)

    Kossow, A; Schaber, S; Kipp, F

    2013-03-01

    The highest proportion of nosocomial infections occurs on intensive care units (ICU) and infections with multiresistant pathogens are an ever increasing problem. Preventative measures should consist of a bundle of different measures including measures that address a specific problem and standard hygiene measures that are relevant in all areas. Specific measures in ICUs primarily aim at the prevention of ventilator associated pneumonia, blood vessel catheter associated infections and nosocomial urinary tract infections. Surface disinfection belongs to the standard hygiene measures and plays an inferior role compared to hand hygiene; however, surfaces come into focus in outbreak situations. The Commission on Hospital Hygiene (KRINKO) at the Robert Koch Institute (the German health protection agency) published recommendations regarding the cleaning and disinfection of surfaces. The frequency with which cleaning and/or disinfection is required varies according to defined areas of risk. The frequency and the disinfection agents used are documented in the disinfection plan.

  8. Impact of egg disinfection of hatching eggs on the eggshell microbiome and bacterial load

    DEFF Research Database (Denmark)

    Olsen, R.; Kudirkiene, E.; Thofner, I.

    2017-01-01

    Disinfection of hatching eggs is essential to ensure high quality production of broilers. Different protocols are followed in different hatcheries; however, only limited scientific evidence on how the disinfection procedures impact the microbiome is available. The aim of the present study...... was to characterize the microbiome and aerobic bacterial load of hatching eggs before disinfection and during the subsequent disinfection steps. The study included a group of visibly clean and a group of visibly dirty eggs. For dirty eggs, an initial wash in chlorine was performed, hereafter all eggs were submitted...... to two times fumigation and finally spray disinfection. The eggshell microbiome was characterized by sequencing of the total amount of 16S rRNA extracted from each sample, consisting of shell surface swabs of five eggs from the same group. In addition, the number of colony forming units (cfu) under...

  9. Resistance of Pseudomonas aeruginosa to liquid disinfectants on contaminated surfaces before formation of biofilms.

    Science.gov (United States)

    Sagripanti, J L; Bonifacino, A

    2000-01-01

    A comparison was made of the effectiveness of popular disinfectants (Cavicide, Cidexplus, Clorox, Exspor, Lysol, Renalin, and Wavicide) under conditions prescribed for disinfection in the respective product labels on Pseudomonas aeruginosa either in suspension or deposited onto surfaces of metallic or polymeric plastic devices. The testing also included 7 nonformulated germicidal agents (glutaraldehyde, formaldehyde, peracetic acid, hydrogen peroxide, sodium hypochlorite, phenol, and cupric ascorbate) commonly used in disinfection and decontamination. Results showed that P. aeruginosa is on average 300-fold more resistant when present on contaminated surfaces than in suspension. This increase in resistance agrees with results reported in studies of biofilms, but unexpectedly, it precedes biofilm formation. The surface to which bacteria are attached can influence the effectiveness of disinfectants. Viable bacteria attached to devices may require dislodging through more than a one-step method for detection. The data, obtained with a sensitive and quantitative test, suggest that disinfectants are less effective on contaminated surfaces than generally acknowledged.

  10. Chemical disinfection of combined sewer overflow waters using performic acid or peracetic acids

    DEFF Research Database (Denmark)

    Chhetri, Ravi Kumar; Thornberg, Dines; Berner, Jesper

    2014-01-01

    We investigated the possibility of applying performic acid (PFA) and peracetic acid (PAA) for disinfection of combined sewer overflow (CSO) in existing CSO management infrastructures. The disinfection power of PFA and PAA towards Escherichia coli (E. coli) and Enterococcus was studied in batch......-scale and pre-field experiments. In the batch-scale experiment, 2.5 mg L− 1 PAA removed approximately 4 log unit of E. coli and Enterococcus from CSO with a 360 min contact time. The removal of E. coli and Enterococcus from CSO was always around or above 3 log units using 2–4 mg L− 1 PFA; with a 20 min contact...... time in both batch-scale and pre-field experiments. There was no toxicological effect measured by Vibrio fischeri when CSO was disinfected with PFA; a slight toxic effect was observed on CSO disinfected with PAA. When the design for PFA based disinfection was applied to CSO collected from an authentic...

  11. Effectiveness of disinfection with alcohol 70% (w/v of contaminated surfaces not previously cleaned

    Directory of Open Access Journals (Sweden)

    Maurício Uchikawa Graziano

    2013-04-01

    Full Text Available OBJECTIVE: To evaluate the disinfectant effectiveness of alcohol 70% (w/v using friction, without previous cleaning, on work surfaces, as a concurrent disinfecting procedure in Health Services. METHOD: An experimental, randomized and single-blinded laboratory study was undertaken. The samples were enamelled surfaces, intentionally contaminated with Serratia marcescens microorganisms ATCC 14756 106 CFU/mL with 10% of human saliva added, and were submitted to the procedure of disinfection WITHOUT previous cleaning. The results were compared to disinfection preceded by cleaning. RESULTS: There was a reduction of six logarithms of the initial microbial population, equal in the groups WITH and WITHOUT previous cleaning (p=0.440 and a residual microbial load ≤ 102 CFU. CONCLUSION: The research demonstrated the acceptability of the practice evaluated, bringing an important response to the area of health, in particular to Nursing, which most undertakes procedures of concurrent cleaning /disinfecting of these work surfaces.

  12. Effectiveness of disinfection with alcohol 70% (w/v of contaminated surfaces not previously cleaned

    Directory of Open Access Journals (Sweden)

    Maurício Uchikawa Graziano

    Full Text Available OBJECTIVE: To evaluate the disinfectant effectiveness of alcohol 70% (w/v using friction, without previous cleaning, on work surfaces, as a concurrent disinfecting procedure in Health Services. METHOD: An experimental, randomized and single-blinded laboratory study was undertaken. The samples were enamelled surfaces, intentionally contaminated with Serratia marcescens microorganisms ATCC 14756 106 CFU/mL with 10% of human saliva added, and were submitted to the procedure of disinfection WITHOUT previous cleaning. The results were compared to disinfection preceded by cleaning. RESULTS: There was a reduction of six logarithms of the initial microbial population, equal in the groups WITH and WITHOUT previous cleaning (p=0.440 and a residual microbial load ≤ 102 CFU. CONCLUSION: The research demonstrated the acceptability of the practice evaluated, bringing an important response to the area of health, in particular to Nursing, which most undertakes procedures of concurrent cleaning /disinfecting of these work surfaces.

  13. Thermomechanical processing of plasma sprayed intermetallic sheets

    Science.gov (United States)

    Hajaligol, Mohammad R.; Scorey, Clive; Sikka, Vinod K.; Deevi, Seetharama C.; Fleischhauer, Grier; Lilly, Jr., A. Clifton; German, Randall M.

    2001-01-01

    A powder metallurgical process of preparing a sheet from a powder having an intermetallic alloy composition such as an iron, nickel or titanium aluminide. The sheet can be manufactured into electrical resistance heating elements having improved room temperature ductility, electrical resistivity, cyclic fatigue resistance, high temperature oxidation resistance, low and high temperature strength, and/or resistance to high temperature sagging. The iron aluminide has an entirely ferritic microstructure which is free of austenite and can include, in weight %, 4 to 32% Al, and optional additions such as .ltoreq.1% Cr, .gtoreq.0.05% Zr .ltoreq.2% Ti, .ltoreq.2% Mo, .ltoreq.1% Ni, .ltoreq.0.75% C, .ltoreq.0.1% B, .ltoreq.1% submicron oxide particles and/or electrically insulating or electrically conductive covalent ceramic particles, .ltoreq.1% rare earth metal, and/or .ltoreq.3% Cu. The process includes forming a non-densified metal sheet by consolidating a powder having an intermetallic alloy composition such as by roll compaction, tape casting or plasma spraying, forming a cold rolled sheet by cold rolling the non-densified metal sheet so as to increase the density and reduce the thickness thereof and annealing the cold rolled sheet. The powder can be a water, polymer or gas atomized powder which is subjecting to sieving and/or blending with a binder prior to the consolidation step. After the consolidation step, the sheet can be partially sintered. The cold rolling and/or annealing steps can be repeated to achieve the desired sheet thickness and properties. The annealing can be carried out in a vacuum furnace with a vacuum or inert atmosphere. During final annealing, the cold rolled sheet recrystallizes to an average grain size of about 10 to 30 .mu.m. Final stress relief annealing can be carried out in the B2 phase temperature range.

  14. Immigrant Education: A Fact Sheet.

    Science.gov (United States)

    Aleman, Steven R.

    This report provides information on immigrant education in the United States in the areas of funding, participation, population, services, and allocation method. Additionally, it explores reauthorization issues confronting the Emergency Immigrant Education Act for fiscal year 1994. The report shows that: (1) there has been a steady decrease in…

  15. Ultraviolet light-emitting diodes in water disinfection.

    Science.gov (United States)

    Vilhunen, Sari; Särkkä, Heikki; Sillanpää, Mika

    2009-06-01

    The novel system of ultraviolet light-emitting diodes (UV LEDs) was studied in water disinfection. Conventional UV lamps, like mercury vapor lamp, consume much energy and are considered to be problem waste after use. UV LEDs are energy efficient and free of toxicants. This study showed the suitability of LEDs in disinfection and provided information of the effect of two emitted wavelengths and different test mediums to Escherichia coli destruction. Common laboratory strain of E. coli (K12) was used and the effects of two emitted wavelengths (269 and 276 nm) were investigated with two photolytic batch reactors both including ten LEDs. The effects of test medium were examined with ultrapure water, nutrient and water, and nutrient and water with humic acids. Efficiency of reactors was almost the same even though the one emitting higher wavelength had doubled optical power compared to the other. Therefore, the effect of wavelength was evident and the radiation emitted at 269 nm was more powerful. Also, the impact of background was studied and noticed to have only slight deteriorating effect. In the 5-min experiment, the bacterial reduction of three to four log colony-forming units (CFU) per cubic centimeter was achieved, in all cases. When turbidity of the test medium was greater, part of the UV radiation was spent on the absorption and reactions with extra substances on liquid. Humic acids can also coat the bacteria reducing the sensitivity of the cells to UV light. The lower wavelength was distinctly more efficient when the optical power is considered, even though the difference of wavelengths was small. The reason presumably is the greater absorption of DNA causing more efficient bacterial breakage. UV LEDs were efficient in E. coli destruction, even if LEDs were considered to have rather low optical power. The effect of wavelengths was noticeable but the test medium did not have much impact. This study found UV LEDs to be an optimal method for bacterial

  16. Disinfection of Biofilms in Tubes with Ultraviolet Light

    DEFF Research Database (Denmark)

    Bak, Jimmy; Begovic, Tanja

    2009-01-01

    Bacterial biofilms on long-term catheters are a major source of infection. We demonstrate here the potential of UVC light emitting diodes (LED) for disinfection purposes in catheter like tubes contaminated with biofilm. We show that UVC Light propagation is possible through teflon tubes using...... to a flow system and biofilms were produced during a three day period. Tubes in lengths of 10 cm (FEP teflon) were contaminated. Tubes for control and for UVC treatment were contaminated in parallel. The control and UVC treated tubes were both filled with a 20 % NaCl solution during the UVC treatment time...

  17. Ultraviolet radiation as disinfection for fish surgical tools

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Ricardo W.; Markillie, Lye Meng; Colotelo, Alison HA; Geist, David R.; Gay, Marybeth E.; Woodley, Christa M.; Eppard, M. B.; Brown, Richard S.

    2013-04-04

    Telemetry is frequently used to examine the behavior of fish, and the transmitters used are normally surgically implanted into the coelomic cavity of fish. Implantation requires the use of surgical tools such as scalpels, forceps, needle holders, and sutures. When fish are implanted consecutively, as in large telemetry studies, it is common for surgical tools to be sterilized or, at minimum, disinfected between each use so that pathogens that may be present are not spread among fish. To determine the efficacy for this application, ultraviolet (UV) radiation was used to disinfect surgical tools exposed to one of four aquatic organisms that typically lead to negative health issues for salmonids. These organisms included Aeromonas salmonicida, Flavobacterium psychrophilum, Renibacterium salmoninarum, and Saprolegnia parasitica, causative agents of furunculosis, coldwater disease, bacterial kidney disease, and saprolegniasis (water mold), respectively. Four experiments were conducted to address the question of UV efficacy. In the first experiment, forceps were exposed to the three bacteria at three varying concentrations. After exposure to the bacterial culture, tools were placed into a mobile Millipore UV sterilization apparatus. The tools were then exposed for three different time periods – 2, 5, or 15 min. UV radiation exposures at all durations were effective at killing all three bacteria on forceps at the highest bacteria concentrations. In the second experiment, stab scalpels, sutures, and needle holders were exposed to A. salmonicida using the same methodology as used in Experiment 1. UV radiation exposure at 5 and 15 min was effective at killing A. salmonicida on stab scalpels and sutures but not needle holders. In the third experiment, S. parasitica, a water mold, was tested using an agar plate method and forceps-pinch method. UV radiation was effective at killing the water mold at all three exposure durations. Collectively, this study shows that UV

  18. Interaction between some disinfectants and Tcsup(99m)-radiopharmaceuticals

    International Nuclear Information System (INIS)

    Verbruggen, A.; Cleynhens, B.; Hoogmartens, M.; De Roo, M.

    1985-01-01

    Contamination of Tcsup(99m) sulphur colloid with small amounts of iodinated antiseptics has been described to result in the formation of free pertechnetate and excessive blood-pool activity upon injection. As far as we know similar or other interactions have not been reported for disinfectants that are effective by another mechanism than oxidizing activity. The present study has been set up to investigate the effect of small amounts of a wide variety of commonly available antiseptics on the radiochemical and biological behaviour of different Tcsup(99m) labelled radiopharmaceuticals. (Auth.)

  19. Plasma sheet behavior during substorms

    International Nuclear Information System (INIS)

    Hones, E.W. Jr.

    1983-01-01

    Auroral or magnetic substorms are periods of enhanced auroral and geomagnetic activity lasting one to a few hours that signify increased dissipation of energy from the magnetosphere to the earth. Data acquired during the past decade from satellites in the near-earth sector of the magnetotail have suggested that during a substorm part of the plasma sheet is severed from earth by magnetic reconnection, forming a plasmoid, i.e., a body of plasma and closed magnetic loops, that flows out of the tail into the solar wind, thus returning plasma and energy that have earlier been accumulated from the solar wind. Very recently this picture has been dramatically confirmed by observations, with the ISEE 3 spacecraft in the magnetotail 220 R/sub E/ from earth, of plasmoids passing that location in clear delayed response to substorms. It now appears that plasmoid release is a fundamental process whereby the magnetosphere gives up excess stored energy and plasma, much like comets are seen to do, and that the phenomena of the substorm seen at earth are a by-product of that fundamental process

  20. Radiation dominated relativistic current sheets

    International Nuclear Information System (INIS)

    Jaroschek, C.H.

    2008-01-01

    Relativistic Current Sheets (RCS) feature plasma instabilities considered as potential key to magnetic energy dissipation and non-thermal particle generation in Poynting flux dominated plasma flows. We show in a series of kinetic plasma simulations that the physical nature of non-linear RCS evolution changes in the presence of incoherent radiation losses: In the ultra-relativistic regime (i.e. magnetization parameter sigma = 104 defined as the ratio of magnetic to plasma rest frame energy density) the combination of non-linear RCS dynamics and synchrotron emission introduces a temperature anisotropy triggering the growth of the Relativistic Tearing Mode (RTM). As direct consequence the RTM prevails over the Relativistic Drift Kink (RDK) Mode as competitive RCS instability. This is in contrast to the previously studied situation of weakly relativistic RCS (sigma ∼ 1) where the RDK is dominant and most of the plasma is thermalized. The simulations witness the typical life cycle of ultra-relativistic RCS evolving from a violent radiation induced collapse towards a radiation quiescent state in rather classical Sweet-Parker topology. Such a transition towards Sweet-Parker configuration in the late non-linear evolution has immediate consequences for the efficiency of magnetic energy dissipation and non-thermal particle generation. Ceasing dissipation rates directly affect our present understanding of non-linear RCS evolution in conventional striped wind scenarios. (author)