WorldWideScience

Sample records for shed blood volume

  1. [Blood conservation effect and safety of shed mediastinal blood autotransfusion after cardiac surgery].

    Science.gov (United States)

    Komiya, T; Ban, K; Yamazaki, K; Date, O; Nakamura, T; Kanzaki, Y

    1998-10-01

    Autotransfusion of shed mediastinal blood after cardiac surgery has been used to reduce risks related to homologous blood transfusions. To document the efficacy and safety of autotransfusion, we compared clinical findings of 80 patients receiving shed mediastinal blood (autotransfusion group) with those of the control group of 52 patients. The amount of the autotransfusion was limited to 800 ml, given the potentially harmful effects of shed blood transfusion. The mean transfused shed volume was 314 +/- 236 ml (S.D.). The serum levels of FDP-E, D-dimer and TAT after autotransfusion were higher in the autotransfusion group than in the control group (p = 0.01, p = 0.0004, p = 0.001, respectively). However, postoperative blood loss and the rate of reexploration for bleeding were similar in the two groups. The patients receiving blood products were fewer in the autotransfusion group than those in the control group (21% vs 44%; p = 0.005). Autotransfusion did not increase postoperative complications, including infection. Thus, although autotransfusion of mediastinal shed blood has the potential to affect hemostasis, unless the amount of autotransfusion exceeds 800 ml, it appears that this method is clinically safe and effective as a mean of blood conservation.

  2. Reinfusion of Shed Blood Following Pediatric Orthopaedic Surgery

    National Research Council Canada - National Science Library

    Blevins, Field

    1991-01-01

    .... The use of a system for salvage and reinfusion of nonwashed shed blood postoperatively is recommended as a safe method to minimize the need for homologous transfusion, especially when there is...

  3. Blood volume studies

    International Nuclear Information System (INIS)

    Lewis, S.M.; Yin, J.A.L.

    1986-01-01

    The use of dilution analysis with such radioisotopes as 51 Cr, 32 P, sup(99m)Tc and sup(113m)In for measuring red cell volume is reviewed briefly. The use of 125 I and 131 I for plasma volume studies is also considered and the subsequent determination of total blood volume discussed, together with the role of the splenic red cell volume. Substantial bibliography. (UK)

  4. Resuscitation from severe hemorrhagic shock after traumatic brain injury using saline, shed blood, or a blood substitute.

    Science.gov (United States)

    Gibson, Jeffrey B; Maxwell, Robert A; Schweitzer, John B; Fabian, Timothy C; Proctor, Kenneth G

    2002-03-01

    The original purpose of this study was to compare initial resuscitation of hemorrhagic hypotension after traumatic brain injury (TBI) with saline and shed blood. Based on those results, the protocol was modified and saline was compared to a blood substitute, diaspirin cross-linked hemoglobin (DCLHb). Two series of experiments were performed in anesthetized and mechanically ventilated (FiO2 = 0.4) pigs (35-45 kg). In Series 1, fluid percussion TBI (6-8 ATM) was followed by a 30% hemorrhage. At 120 min post-TBI, initial resuscitation consisted of either shed blood (n = 7) or a bolus of 3x shed blood volume as saline (n = 13). Saline supplements were then administered to all pigs to maintain a systolic arterial blood pressure (SAP) of >100 mmHg and a heart rate (HR) of 100 mmHg and a HR of CO2 reactivity was preserved with blood vs. saline (all P CO2 reactivity were improved, and ScvO2 was lower with DCLHb vs. saline (P effective than saline for resuscitation of TBI, whereas DCLHb was no more, and according to many variables, less effective than saline resuscitation. These experimental results are comparable to those in a recent multicenter trial using DCLHb for the treatment of severe traumatic shock. Further investigations in similar experimental models might provide some plausible explanations why DCLHb unexpectedly increased mortality in patients.

  5. Cardiorespiratory effects of venous lipid micro embolization in an experimental model of mediastinal shed blood reinfusion

    Directory of Open Access Journals (Sweden)

    Dencker Magnus

    2009-09-01

    Full Text Available Abstract Background Retransfusion of the patient's own blood during surgery is used to reduce the need for allogenic blood transfusion. It has however been found that this blood contains lipid particles, which form emboli in different organs if the blood is retransfused on the arterial side. In this study, we tested whether retransfusion of blood containing lipid micro-particles on the venous side in a porcine model will give hemodynamic effects. Methods Seven adult pigs were used. A shed blood surrogate containing 400 ml diluted blood and 5 ml radioactive triolein was produced to generate a lipid embolic load. The shed blood surrogate was rapidly ( Results A more than 30-fold increase in pulmonary vascular resistance was observed, with subsequent increase in pulmonary artery pressure, and decrease in cardiac output and arterial pressure. This response was transient, but was followed by a smaller, persistent increase in pulmonary vascular resistance. Only a small portion of the infused triolein passed the lungs, and only a small fraction could be recirculated by increasing cardiac output and pulmonary pressure. Conclusion Infusion of blood containing lipid micro-emboli on the venous side leads to acute, severe hemodynamic responses that can be life threatening. Lipid particles will be trapped in the lungs, leading to persistent effects on the pulmonary vascular resistance.

  6. Reduced central blood volume in cirrhosis

    DEFF Research Database (Denmark)

    Bendtsen, F; Henriksen, Jens Henrik Sahl; Sørensen, T I

    1989-01-01

    than 0.0001). The lowest values (18 ml/kg) were found in patients with gross ascites and a reduced systemic vascular resistance. In patients with cirrhosis central blood volume was inversely correlated to the hepatic venous pressure gradient (r = -0.41, p less than 0.01), and the total blood volume...... was inversely correlated to the systemic vascular resistance (r = -0.49, p less than 0.001), the latter being significantly reduced in the patient group. Patients with cirrhosis apparently are unable to maintain a normal central blood volume. This may be due to arteriolar vasodilation, portosystemic collateral...

  7. Blood flow and blood volume in a transplanted rat fibrosarcoma

    International Nuclear Information System (INIS)

    Tozer, G.M.; Morris, C.C.

    1990-01-01

    Blood flow measurements following i.v. infusion of iodi-antipyrine labelled with 14 C ( 14 C-IAP) and blood volume measurements following i.v. injection of 125 I human serum albumin and 51 Cr-labelled red blood cells were made in a transplanted rat fibrosarcoma for comparison with various normal tissues. The tumour-blood partition co-efficient for 14 C-IAP w as found to be 0.79 ± 0.07 which is similar to most of the normal tissues studied. The solubility of 14 C-IAP in plasma was found to be higher than that in whole blood. Blood flow to tumours 3 was found to be 17.9 ± 4.0 ml blood 100 g tissue -1 xmin -1 . These values were considered to be primarily measurements of nutritive flow. Blood in the tumours was found to occupy around 1% of the tissue space which was similar to that found for normal muscle and skin. There was no direct correlation between % blood volume and blood flow for the different tissues studied. Th haematocrit of blood contained in tumour tissue was calculated to be significantly lower than that of blood contained in the normal tissues. It was suspected that permeability of tumour blood vessel walls to 125 I-HSA could have accounted for this difference. (author). 41 refs.; 2 figs.; 3 tabs

  8. Tissue hepatic blood volume and liver function

    International Nuclear Information System (INIS)

    Masuyama, Mamoru

    1997-01-01

    Positron emission tomography (PET) scan has an advantage that it can measure regional organ blood flow and volume not only quantitatively but also non-invasively. In order to estimate the liver function, tissue hepatic blood volume was measured using C 15 O inhalation in conjunction with positron emission tomography. PET scans of the liver were performed after the single breath inhalation of 20 mCi of high specific activity 15 O-labeled carbon monoxide in 105 patients which were classified 3 groups; normal, chronic hepatitis, and cirrhosis. They consist of 61, 14, and 30 patients, respectively. Significant differences between normal and cirrhotic patients were noted in tissue hepatic blood volume (mean 20.4, 18.2, 16.0 ml/100 g, respectively). Tissue hepatic blood volume (tHBV) correlated with the reaction of the peripheral reticuloendothelial compartment and protein synthesis, because there was a potent correlation between tHBV and hepatic fibrosis. In normal livers, we were able to demonstrate significant differences in tissue hepatic blood volume among liver segments. (author)

  9. Immersive volume rendering of blood vessels

    Science.gov (United States)

    Long, Gregory; Kim, Han Suk; Marsden, Alison; Bazilevs, Yuri; Schulze, Jürgen P.

    2012-03-01

    In this paper, we present a novel method of visualizing flow in blood vessels. Our approach reads unstructured tetrahedral data, resamples it, and uses slice based 3D texture volume rendering. Due to the sparse structure of blood vessels, we utilize an octree to efficiently store the resampled data by discarding empty regions of the volume. We use animation to convey time series data, wireframe surface to give structure, and utilize the StarCAVE, a 3D virtual reality environment, to add a fully immersive element to the visualization. Our tool has great value in interdisciplinary work, helping scientists collaborate with clinicians, by improving the understanding of blood flow simulations. Full immersion in the flow field allows for a more intuitive understanding of the flow phenomena, and can be a great help to medical experts for treatment planning.

  10. Safety of retransfusing shed blood after local infiltration analgesia in total knee arthroplasty

    NARCIS (Netherlands)

    Thomassen, B.J.; Pool, L.; Van Der Flier, R.; Stienstra, R.; in 't Veld, B.A.

    2012-01-01

    We investigated the safety of LIA (local infiltration analgesia) combined with retransfusion of drained blood. Total knee arthroplasty patients received two peri-articular injections during surgery followed by continuous infusion, both with ropivacaine (567 mg). Ropivacaine plasma concentrations

  11. Cerebral blood volume alterations during fractional pneumoencephalography

    International Nuclear Information System (INIS)

    Voigt, K.; Greitz, T.

    1976-01-01

    Simultaneous and continuous measurements of the cerebral blood volume (CBV), cerebrospinal fluid (CSF) and blood pressure were carried out in six patients during fractional pneumoencephalography in order to examine intracranial volumetric interactions. Three patients (Group A) showed normal encephalographic findings, and in three patients (Group B) communicating hydrocephalus with convexity block was found encephalographically. In all patients the injection of air was followed by an immediate increase of CSF pressure and blood pressure and a concomitant decrease of CBV. The initial CSF pressure was invariably re-established within 3 to 3.5 min. During this time interval the CBV of the patients of Group B decreased significantly and 30 percent more than that of Group A. Furthermore, after restoration of the original CSF pressure, CBV returned to its initial level in all patients of Group A, whereas it remained unchanged or showed a further decrease in the patients of Group B. Removal of an amount of CSF corresponding to half of the amount of injected air was followed by a significant reactive hyperemic response in two normal patients. The intracranial volumetric alterations during fractional pneumoencephalography are discussed in detail with respect to the underlying physiologic mechanisms and are suggested as a model for acute and low pressure hydrocephalus

  12. Relative blood volume changes underestimate total blood volume changes during hemodialysis

    NARCIS (Netherlands)

    Dasselaar, Judith J.; Lub-de Hooge, Marjolijn N.; Pruim, Jan; Nijnuis, Hugo; Wiersum, Anneke; de Jong, Paul E.; Huisman, Roel M.; Franssen, Casper F. M.

    Background: Measurements of relative blood volume changes (ARBV) during hemodialysis (HD) are based on hemoconcentration and assume uniform mixing of erythrocytes and plasma throughout the circulation. However, whole-body hematocrit (Ht) is lower than systemic Ht. During HD, a change in the ratio

  13. Variations in gastric emptying of liquid elicited by acute blood volume changes in awake rats

    Directory of Open Access Journals (Sweden)

    Gondim F. de-A.A.

    1998-01-01

    Full Text Available We have observed that acute blood volume expansion increases the gastroduodenal resistance to the flow of liquid in anesthetized dogs, while retraction decreases it (Santos et al. (1991 Acta Physiologica Scandinavica, 143: 261-269. This study evaluates the effect of blood volume expansion and retraction on the gastric emptying of liquid in awake rats using a modification of the technique of Scarpignato (1980 (Archives Internationales de Pharmacodynamie et de Therapie, 246: 286-294. Male Wistar rats (180-200 g were fasted for 16 h with water ad libitum and 1.5 ml of the test meal (0.5 mg/ml phenol red solution in 5% glucose was delivered to the stomach immediately after random submission to one of the following protocols: 1 normovolemic control (N = 22, 2 expansion (N = 72 by intravenous infusion (1 ml/min of Ringer-bicarbonate solution, volumes of 1, 2, 3 or 5% body weight, or 3 retraction (N = 22 by controlled bleeding (1.5 ml/100 g. Gastric emptying of liquid was inhibited by 19-51.2% (P<0.05 after blood volume expansion (volumes of 1, 2, 3 or 5% body weight. Blood volume expansion produced a sustained increase in central venous pressure while mean arterial pressure was transiently increased during expansion (P<0.05. Blood volume retraction increased gastric emptying by 28.5-49.9% (P<0.05 and decreased central venous pressure and mean arterial pressure (P<0.05. Infusion of the shed blood 10 min after bleeding reversed the effect of retraction on gastric emptying. These findings suggest that gastric emptying of liquid is subject to modulation by the blood volume.

  14. Post-mortem virtual estimation of free abdominal blood volume

    International Nuclear Information System (INIS)

    Ampanozi, Garyfalia; Hatch, Gary M.; Ruder, Thomas D.; Flach, Patricia M.; Germerott, Tanja; Thali, Michael J.; Ebert, Lars C.

    2012-01-01

    Purpose: The purpose of this retrospective study was to examine the reliability of virtually estimated abdominal blood volume using segmentation from postmortem computed tomography (PMCT) data. Materials and methods: Twenty-one cases with free abdominal blood were investigated by PMCT and autopsy. The volume of the blood was estimated using a manual segmentation technique (Amira, Visage Imaging, Germany) and the results were compared to autopsy data. Six of 21 cases had undergone additional post-mortem computed tomographic angiography (PMCTA). Results: The virtually estimated abdominal blood volumes did not differ significantly from those measured at autopsy. Additional PMCTA did not bias data significantly. Conclusion: Virtual estimation of abdominal blood volume is a reliable technique. The virtual blood volume estimation is a useful tool to deliver additional information in cases where autopsy is not performed or in cases where a postmortem angiography is performed

  15. Peripheral blood volume influenced by various external factors

    Energy Technology Data Exchange (ETDEWEB)

    Ittner, A; Scheibe, J; Stoll, W [Friedrich-Schiller-Universitaet, Jena (German Democratic Republic). Bereich Medizin

    1982-01-01

    The dependence of the peripheral blood volume upon various exogenous factors was studied in male sports students using /sup 113m/InCl. The results obtained revealed that whole-body exertions and local muscular activity produce an increase of the blood volume in the lower extremities associated with increased blood circulation. The passive measures applied caused also an increase of the blood volume, but not in all of the subjects examined. Isometric concentrations led to a highly significant reduction of the peripheral blood volume. The scintigraphic method for the visualization of the blood volume in peripheral regions of the body can be regarded as suitable for the study of hemodynamics and for the substantiation of the efficiency of measures promoting restoration.

  16. The peripheral blood volume influenced by various external factors

    International Nuclear Information System (INIS)

    Ittner, A.; Scheibe, J.; Stoll, W.

    1982-01-01

    The dependence of the peripheral blood volume upon various exogenous factors was studied in male sports students using /sup 113m/InCl. The results obtained revealed that whole-body exertions and local muscular activity produce an increase of the blood volume in the lower extremities associated with increased blood circulation. The passive measures applied caused also an increase of the blood volume, but not in all of the subjects examined. Isometric concentrations led to a highly significant reduction of the peripheral blood volume. The scintigraphic method for the visualization of the blood volume in peripheral regions of the body can be regarded as suitable for the study of hemodynamics and for the substantiation of the efficiency of measures promoting restoration. (author)

  17. Critical evaluation of blood volume measurements during hemodialysis.

    Science.gov (United States)

    Dasselaar, Judith J; van der Sande, Frank M; Franssen, Casper F M

    2012-01-01

    Devices that continuously measure relative blood volume (RBV) changes during hemodialysis (HD) are increasingly used for the prevention of dialysis hypotension and fine-tuning of dry weight. However, RBV measurements are subject to various limitations. First, RBV devices provide information on relative blood volume changes but not on absolute blood volume. Since blood volume varies with the hydration status, identical reductions of RBV may result in very different absolute blood volumes at the end of HD. Second, RBV changes underestimate the change of total blood volume due to translocation of lower-hematocrit blood from the microcirculation to the central circulation. Third, changes in posture before and during HD, food intake, exercise, and administration of intravenous fluids may influence the validity of the RBV measurement. Fourth, results obtained by various RBV devices show large interdevice differences. Finally, although a fall in blood volume is an important factor in dialysis hypotension, frank dialysis hypotension only occurs when the cardiovascular compensatory mechanisms can no longer compensate for the reduction in blood volume. Therefore, the dialysis staff should not exclusively focus on RBV, but also search for opportunities in the dialysis prescription to facilitate cardiovascular compensatory mechanisms, e.g. by lowering dialysate temperature. In the opinion of the authors, routine RBV monitoring should be used with caution until the major conceptual and methodological problems that are inherent to the indirect RBV estimation are clarified. Copyright © 2012 S. Karger AG, Basel.

  18. Effect of volume expansion on systemic hemodynamics and central and arterial blood volume in cirrhosis

    DEFF Research Database (Denmark)

    Møller, S; Bendtsen, F; Henriksen, Jens Henrik Sahl

    1995-01-01

    , and arterial pressure were determined before and during a volume expansion induced by infusion of a hyperosmotic galactose solution. RESULTS: During volume expansion, the central and arterial blood volume increased significantly in patients with class A and controls, whereas no significant change was found...... in patients with either class B or class C. Conversely, the noncentral blood volume increased in patients with class B and C. In both patients and controls, the cardiac output increased and the systemic vascular resistance decreased, whereas the mean arterial blood pressure did not change significantly......BACKGROUND & AIMS: Systemic vasodilatation in cirrhosis may lead to hemodynamic alterations with reduced effective blood volume and decreased arterial blood pressure. This study investigates the response of acute volume expansion on hemodynamics and regional blood volumes in patients with cirrhosis...

  19. Determination of the blood volume of rabbits (1963)

    International Nuclear Information System (INIS)

    Bernard, Y.; Pierotti, Th.; Rinaldi, R.

    1963-01-01

    The knowledge of the ratio of the blood volume to the weight of an animal is of a great deal in various experiments. Therefore authors have decided to determine this ratio for rabbits by using chromium 51. Results show that the blood volume represents about 54.4 g per kilogram of body weight. (authors) [fr

  20. blood and plasma volumes in normal west african dwarf sheep

    African Journals Online (AJOL)

    Dr Olaleye

    volume (PCV) and haemoglobin (Hb) values were determined as descried by Benjamin (1978) using the microhaematocrit and ... Standard dye concentration of 20 mg/ml was used for determining the dye concentration in plasma. ... Haemoglobin (Hb), Plasma Volume and Blood Volume in the West African Dwarf. Sheep.

  1. Blood and plasma volumes in normal west African dwarf sheep ...

    African Journals Online (AJOL)

    Blood and plasma volumes were determined using T-1824 in 36 normal adult West African Dwarf sheep. In the rams, dry ewes, pregnant ewes and lactating ewes, the mean values for the blood volume (ml/kg body weight) were 64.08 ± 6.11, 55.74 ± 9.31, 71.46 ± 6.46 and 147.12 ± 12.79 respectively, while the mean values ...

  2. Effect of pulmonary hyperinflation on central blood volume

    DEFF Research Database (Denmark)

    Mijacika, Tanja; Kyhl, Kasper; Frestad, Daria

    2017-01-01

    (11±7%) above the total lung capacity. All cardiac chambers decreased in volume and despite a heart rate increase of 24±29 bpm (39±50%), pulmonary blood flow decreased by 2783±1820mL (43±20%). The pulmonary transit time remained unchanged at 7.5±2.2s and pulmonary blood volume decreased by 354±176m...

  3. Determination of blood volume by pulse CO-oximetry

    International Nuclear Information System (INIS)

    Lalande, S; Kelsey, J W; Joyner, M J; Johnson, B D

    2012-01-01

    The objective of this study was to determine whether changes in carboxyhaemoglobin (COHb) saturation following carbon monoxide (CO) rebreathing can be accurately detected by pulse CO-oximetry in order to determine blood volume. Noninvasive measurements of carboxyhaemoglobin saturation (SpCO) were continuously monitored by pulse CO-oximetry before, during and following 2 min of CO rebreathing. Reproducibility and accuracy of noninvasive blood volume measurements were determined in 16 healthy non-smoking individuals (15 males, age: 28 ± 2 years, body mass index: 25.4 ± 0.6 kg m −2 ) through comparison with blood volume measurements calculated from invasive measurements of COHb saturation. The coefficient of variation for noninvasive blood volume measurements performed on separate days was 15.1% which decreases to 9.1% when measurements were performed on the same day. Changes in COHb saturation and SpCO following CO rebreathing were strongly correlated (r = 0.90, p < 0.01), resulting in a significant correlation between invasive and noninvasive blood volume measurements (r = 0.83, p = 0.02). Changes in SpCO following CO rebreathing can be accurately detected by pulse CO-oximetry, which could potentially provide a simplified, convenient and reproducible method to rapidly determine blood volume in healthy individuals

  4. Radionuclide method for blood volume determination in kidneys

    International Nuclear Information System (INIS)

    Trindev, P.; Nikolov, D.; Shejretova, E.; Garcheva-Tsacheva, M.

    1989-01-01

    The method is applied in nephrology for diagnosing changes in blood circulation of the kidneys. The blood volume of each kidney is determined separately by perfusion angioscintigraphy (PAS) with improved accuracy. The method consists in intravenous injection of 300-450 MBq 99m Tc for in-vivo labelling of the erythrocytes. About 30 images are registered every 2 sec, and through zones of interest perfusion histograms of kidneys are derived. Ten minutes later kidneys images (one full-face and two profiles) are registered. Correction coefficients for kidneys depth are derived and the activities registered according to full-face images and amplitudes of perfusion histograms are corrected. The activity of 1 ml blood is determined from blood sample of the patient. The blood volume of each kidney is expressed as a ratio of the activity corrected for background and depth and the activity of 1 ml blood of the sample. 1 claim

  5. The cost of post-operative shed blood salvage after total knee arthroplasty: an analysis of 1,093 consecutive procedures

    Science.gov (United States)

    Muñoz, Manuel; Ariza, Daniel; Campos, Arturo; Martín-Montañez, Elisa; Pavía, José

    2013-01-01

    Background Requirements for allogeneic red cell transfusion after total knee arthroplasty are still high (20–50%), and salvage and reinfusion of unwashed, filtered post-operative shed blood is an established method for reducing transfusion requirements following this operation. We performed a cost analysis to ascertain whether this alternative is likely to be cost-effective. Materials and methods Data from 1,093 consecutive primary total knee arthroplasties, managed with (reinfusion group, n=763) or without reinfusion of unwashed salvaged blood (control group, n=330), were retrospectively reviewed. The costs of low-vacuum drains, shed blood collection canisters (Bellovac ABT®, Wellspect HealthCare and ConstaVac CBC II®, Stryker), shed blood reinfusion, acquisition and transfusion of allogeneic red cell concentrate, haemoglobin measurements, and prolonged length of hospital stay were used for the blood management cost analysis. Results Patients in the reinfusion group received 152±64 mL of red blood cells from postoperatively salvaged blood, without clinically relevant incidents, and showed a lower allogeneic transfusion rate (24.5% vs 8.5%, for the control and reinfusion groups, respectively; p =0.001). There were no differences in post-operative infection rates. Patients receiving allogeneic transfusions stayed in hospital longer (+1.9 days [95% CI: 1.2 to 2.6]). As reinfusion of unwashed salvaged blood reduced the allogeneic transfusion rate, both reinfusion systems may provide net savings in different cost scenarios (€ 4.6 to € 106/patient for Bellovac ABT, and € −51.9 to € 49.9/patient for ConstaVac CBCII). Discussion Return of unwashed salvaged blood after total knee arthroplasty seems to save costs in patients with pre-operative haemoglobin between 12 and 15 g/dL. It is not cost-saving in patients with a pre-operative haemoglobin >15 g/dL, whereas in those with a pre-operative haemoglobin cost-saving, its efficacy could be increased by

  6. Pediatric blood volumes: a one-page reference guide.

    Science.gov (United States)

    Smiley, J; Reitan, J

    1998-10-01

    At our institution, a multidisciplinary team met to work out a blood volume policy for our pediatric patients' laboratory testing. Because we are a cancer center, many of our patients are on protocols and/or are in the hospital for an extended period of time. These factors result in multiple blood draws. It is important to manage the volumes used so that we do not compromise the hematological status of our pediatric patients. The concerns of nurses and laboratory technologists were discussed and a three-tiered system was designed consisting of adult volumes, volumes for inflexibility to verify or add to the original order without resticking the patient increase at each tier. It is imperative to the overall quality of care for all patients that discretion is used when following these guidelines. When it is medically prudent to restrict the blood volumes taken from any patient, it should be done. However, when it is not medically necessary, the increased costs and potential decrease in the quality of laboratory service outweighs the desire to use smaller blood volumes.

  7. Correlation of ultrasound estimated placental volume and umbilical cord blood volume in term pregnancy.

    Science.gov (United States)

    Pannopnut, Papinwit; Kitporntheranunt, Maethaphan; Paritakul, Panwara; Kongsomboon, Kittipong

    2015-01-01

    To investigate the correlation between ultrasound measured placental volume and collected umbilical cord blood (UCB) volume in term pregnancy. An observational cross-sectional study of term singleton pregnant women in the labor ward at Maha Chakri Sirindhorn Medical Center was conducted. Placental thickness, height, and width were measured using two-dimensional (2D) ultrasound and calculated for placental volume using the volumetric mathematic model. After the delivery of the baby, UCB was collected and measured for its volume immediately. Then, birth weight, placental weight, and the actual placental volume were analyzed. The Pearson's correlation was used to determine the correlation between each two variables. A total of 35 pregnant women were eligible for the study. The mean and standard deviation of estimated placental volume and actual placental volume were 534±180 mL and 575±118 mL, respectively. The median UCB volume was 140 mL (range 98-220 mL). The UCB volume did not have a statistically significant correlation with the estimated placental volume (correlation coefficient 0.15; p=0.37). However, the UCB volume was significantly correlated with the actual placental volume (correlation coefficient 0.62; pcorrelation coefficient 0.38; p=0.02). The estimated placental volume by 2D ultrasound was not significantly correlated with the UCB volume. Further studies to establish the correlation between the UCB volume and the estimated placental volume using other types of placental imaging may be needed.

  8. Estimation of lung volume and pulmonary blood volume from radioisotopic images

    International Nuclear Information System (INIS)

    Kanazawa, Minoru

    1989-01-01

    Lung volume and pulmonary blood volume in man were estimated from the radioisotopic image using single photon emission computed tomography (SPECT). Six healthy volunteers were studied in a supine position with normal and altered lung volumes by applying continuous negative body-surface pressure (CNP) and by positive end-expiratory pressure (PEEP). 99m Tc labeled human serum albumin was administered as an aerosol to image the lungs. The CNP caused the diaphragm to be lowered and it increased the mean lung tissue volume obtained by SPECT from 3.09±0.49 l for baseline to 3.67±0.62 l for 10 cmH 2 O (p 2 O (p 2 O), respectively. The PEEP also increased the lung tissue volume to 3.68±0.68 l for 10 cmH 2 O as compared with the baseline (p 2 O PEEP. The lung tissue volume obtained by SPECT showed a positive correlation with functional residual capacity measured by the He dilution method (r=0.91, p 99m Tc-labeled red blood cells. The L/H ratio decreased after either the CNP or PEEP, suggesting a decrease in the blood volume per unit lung volume. However, it was suggested that the total pulmonary blood volume increased slightly either on the CNP (+7.4% for 10 cmH 2 O, p 2 O,p<0.05) when we extrapolated the L/H ratio to the whole lungs by multiplying the lung tissue volume obtained by SPECT. We concluded that SPECT could offer access to the estimation of lung volume and pulmonary blood volume in vivo. (author)

  9. Radionuclide determined pulmonary blood volume in ischaemic heart disease

    International Nuclear Information System (INIS)

    Hannan, W.J.; Vojacek, J.; Connell, H.M. Dewhurst N.G.; Muir, A.L.

    1981-01-01

    Most measurements of pulmonary blood volume have been based on the Stewart-Hamilton dye dilution principle and have required direct catheterisation of the cardiac chambers. Alternatively a precordial counter may be used to detect the composite right and left heart curves after an intravenous injection of radionuclide. We investigated the use of a gamma camera/computer system to determine the radionuclide (sup(99m)Tc) dilution curves from individual cardiac chambers. Pulmonary transit time and pulmonary blood volume were measured in nine normal subjects, eight patients with angina pectoris but without heart failure, and 13 patients with ischaemic heart disease and left ventricular failure. Patients with heart failure had significantly greater (p 0 angle. A reduction in pulmonary blood volume in the tilted position was observed in each subject (p < 0.005). This simple non-invasive measurement should allow more detailed assessment of physiological or pharmacological changes of the pulmonary vascular bed. (author)

  10. The determination of chromium-50 in human blood and its utilization for blood volume measurements

    International Nuclear Information System (INIS)

    Zeisler, R.; Young, I.

    1986-01-01

    Possible relationships between insufficient blood volume increases during pregnancy and infant mortality could be established with an adequate measurement procedure. An accurate and precise technique for blood volume measurements has been found in the isotope dilution technique using chromium-51 as a label for red blood cells. However, in a study involving pregnant women, only stable isotopes can be used for labeling. Stable chromium-50 can be determined in total blood samples before and after dilution experiments by neutron activation analysis (NAA) or mass spectrometry. However, both techniques may be affected by insufficient sensitivity and contamination problems at the inherently low natural chromium concentrations to be measured in the blood. NAA procedures involving irradiations with highly thermalized neutrons at a fluence rate of 2x10 13 n/cm 2 xs and low background gamma spectrometry are applied to the analysis of total blood. Natural levels of chromium-50 in human and animal blood have been found to be <0.1 ng/mL; i.e., total chromium levels of <3 ng/mL. Based on the NAA procedure, a new approach to the blood volume measurement via chromium-50 isotope dilution has been developed which utilizes the ratio of the induced activities of chromium-51 to the iron-59 in three blood samples taken from each individual, namely blank, labeled and diluted labeled blood. (author)

  11. Effect of high and low ultrafiltration volume during hemodialysis on relative blood volume

    NARCIS (Netherlands)

    Dasselaar, JJ; de Jong, PE; Huisman, RM; Franssen, CFM

    2006-01-01

    Achieving an optimal posthemodialysis hydration status may be difficult because objective criteria for dry weight are lacking. Both relative blood volume changes (Delta RBV) at the end of hemodialysis and Delta RBV normalized for ultrafiltration volume (Delta RBV/UF ratio) have been reported to

  12. A reference frame for blood volume in children and adolescents

    Directory of Open Access Journals (Sweden)

    Donckerwolcke Raymond

    2006-02-01

    Full Text Available Abstract Background Our primary purpose was to determine the normal range and variability of blood volume (BV in healthy children, in order to provide reference values during childhood and adolescence. Our secondary aim was to correlate these vascular volumes to body size parameters and pubertal stages, in order to determine the best normalisation parameter. Methods Plasma volume (PV and red cell volume (RCV were measured and F-cell ratio was calculated in 77 children with idiopathic nephrotic syndrome in drug-free remission (mean age, 9.8 ± 4.6 y. BV was calculated as the sum of PV and RCV. Due to the dependence of these values on age, size and sex, all data were normalised for body size parameters. Results BV normalised for lean body mass (LBM did not differ significantly by sex (p Conclusion LBM was the anthropometric index most closely correlated to vascular fluid volumes, independent of age, gender and pubertal stage.

  13. Critical Evaluation of Blood Volume Measurements during Hemodialysis

    NARCIS (Netherlands)

    Dasselaar, Judith J.; van der Sande, Frank M.; Franssen, Casper F. M.

    2012-01-01

    Devices that continuously measure relative blood volume (RBV) changes during hemodialysis (HD) are increasingly used for the prevention of dialysis hypotension and fine-tuning of dry weight. However, RBV measurements are subject to various limitations. First, RBV devices provide information on

  14. Muscle blood volume assessment during exercise with Power Doppler Ultrasound

    NARCIS (Netherlands)

    Heres, H.M.; Tchang, B.C.Y.; Schoots, T.; Rutten, M.C.M.; van de Vosse, F.N.; Lopata, R.G.P.

    2016-01-01

    Assessment of perfusion adaptation in muscle during exercise can provide diagnostic information on cardiac and endothelial diseases. Power Doppler Ultrasound (PDUS) is known for its feasibility in the non-invasive measurement of moving blood volume (MBV), a perfusion related parameter. In this

  15. 21 CFR 864.5950 - Blood volume measuring device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood volume measuring device. 864.5950 Section 864.5950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices...

  16. Influence of Gravity on Blood Volume and Flow Distribution

    Science.gov (United States)

    Pendergast, D.; Olszowka, A.; Bednarczyk, E.; Shykoff, B.; Farhi, L.

    1999-01-01

    In our previous experiments during NASA Shuttle flights SLS 1 and 2 (9-15 days) and EUROMIR flights (30-90 days) we observed that pulmonary blood flow (cardiac output) was elevated initially, and surprisingly remained elevated for the duration of the flights. Stroke volume increased initially and then decreased, but was still above 1 Gz values. As venous return was constant, the changes in SV were secondary to modulation of heart rate. Mean blood pressure was at or slightly below 1 Gz levels in space, indicating a decrease in total peripheral resistance. It has been suggested that plasma volume is reduced in space, however cardiac output/venous return do not return to 1 Gz levels over the duration of flight. In spite of the increased cardiac output, central venous pressure was not elevated in space. These data suggest that there is a change in the basic relationship between cardiac output and central venous pressure, a persistent "hyperperfusion" and a re-distribution of blood flow and volume during space flight. Increased pulmonary blood flow has been reported to increase diffusing capacity in space, presumably due to the improved homogeneity of ventilation and perfusion. Other studies have suggested that ventilation may be independent of gravity, and perfusion may not be gravity- dependent. No data for the distribution of pulmonary blood volume were available for flight or simulated microgravity. Recent studies have suggested that the pulmonary vascular tree is influenced by sympathetic tone in a manner similar to that of the systemic system. This implies that the pulmonary circulation is dilated during microgravity and that the distribution of blood flow and volume may be influenced more by vascular control than by gravity. The cerebral circulation is influenced by sympathetic tone similarly to that of the systemic and pulmonary circulations; however its effects are modulated by cerebral autoregulation. Thus it is difficult to predict if cerebral perfusion is

  17. An Angiotensin I-Converting Enzyme Mutation (Y465D) Causes a Dramatic Increase in Blood ACE via Accelerated ACE Shedding

    Science.gov (United States)

    Gordon, Kerry; Nesterovitch, Andrew B.; Lünsdorf, Heinrich; Chen, Zhenlong; Castellon, Maricela; Popova, Isolda A.; Kalinin, Sergey; Mendonca, Emma; Petukhov, Pavel A.; Schwartz, David E.

    2011-01-01

    Background Angiotensin I-converting enzyme (ACE) metabolizes a range of peptidic substrates and plays a key role in blood pressure regulation and vascular remodeling. Thus, elevated ACE levels may be associated with an increased risk for different cardiovascular or respiratory diseases. Previously, a striking familial elevation in blood ACE was explained by mutations in the ACE juxtamembrane region that enhanced the cleavage-secretion process. Recently, we found a family whose affected members had a 6-fold increase in blood ACE and a Tyr465Asp (Y465D) substitution, distal to the stalk region, in the N domain of ACE. Methodology/Principal Findings HEK and CHO cells expressing mutant (Tyr465Asp) ACE demonstrate a 3- and 8-fold increase, respectively, in the rate of ACE shedding compared to wild-type ACE. Conformational fingerprinting of mutant ACE demonstrated dramatic changes in ACE conformation in several different epitopes of ACE. Cell ELISA carried out on CHO-ACE cells also demonstrated significant changes in local ACE conformation, particularly proximal to the stalk region. However, the cleavage site of the mutant ACE - between Arg1203 and Ser1204 - was the same as that of WT ACE. The Y465D substitution is localized in the interface of the N-domain dimer (from the crystal structure) and abolishes a hydrogen bond between Tyr465 in one monomer and Asp462 in another. Conclusions/Significance The Y465D substitution results in dramatic increase in the rate of ACE shedding and is associated with significant local conformational changes in ACE. These changes could result in increased ACE dimerization and accessibility of the stalk region or the entire sACE, thus increasing the rate of cleavage by the putative ACE secretase (sheddase). PMID:21998728

  18. An angiotensin I-converting enzyme mutation (Y465D causes a dramatic increase in blood ACE via accelerated ACE shedding.

    Directory of Open Access Journals (Sweden)

    Sergei M Danilov

    Full Text Available Angiotensin I-converting enzyme (ACE metabolizes a range of peptidic substrates and plays a key role in blood pressure regulation and vascular remodeling. Thus, elevated ACE levels may be associated with an increased risk for different cardiovascular or respiratory diseases. Previously, a striking familial elevation in blood ACE was explained by mutations in the ACE juxtamembrane region that enhanced the cleavage-secretion process. Recently, we found a family whose affected members had a 6-fold increase in blood ACE and a Tyr465Asp (Y465D substitution, distal to the stalk region, in the N domain of ACE.HEK and CHO cells expressing mutant (Tyr465Asp ACE demonstrate a 3- and 8-fold increase, respectively, in the rate of ACE shedding compared to wild-type ACE. Conformational fingerprinting of mutant ACE demonstrated dramatic changes in ACE conformation in several different epitopes of ACE. Cell ELISA carried out on CHO-ACE cells also demonstrated significant changes in local ACE conformation, particularly proximal to the stalk region. However, the cleavage site of the mutant ACE--between Arg1203 and Ser1204--was the same as that of WT ACE. The Y465D substitution is localized in the interface of the N-domain dimer (from the crystal structure and abolishes a hydrogen bond between Tyr465 in one monomer and Asp462 in another.The Y465D substitution results in dramatic increase in the rate of ACE shedding and is associated with significant local conformational changes in ACE. These changes could result in increased ACE dimerization and accessibility of the stalk region or the entire sACE, thus increasing the rate of cleavage by the putative ACE secretase (sheddase.

  19. Measurement of regional pulmonary blood volume in patients with increased pulmonary blood flow or pulmonary arterial hypertension

    International Nuclear Information System (INIS)

    Wollmer, P.; Rozcovek, A.; Rhodes, C.G.; Allan, R.M.; Maseri, A.

    1984-01-01

    The effects of chronic increase in pulmonary blood flow and chronic pulmonary hypertension on regional pulmonary blood volume was measured in two groups of patients. One group of patients had intracardiac, left-to-right shunts without appreciable pulmonary hypertension, and the other consisted of patients with Eisenmenger's syndrome or primary pulmonary hypertension, i.e. patients with normal or reduced blood flow and severe pulmonary hypertension. A technique based on positron tomography was used to measure lung density (by transmission scanning) and regional pulmonary blood volume (after inhalation of /sup 11/CO). The distribution of pulmonary blood volume was more uniform in patients with chronic increase in pulmonary blood flow than in normal subjects. There were also indications of an absolute increase in intrapulmonary blood volume by about 15%. In patients with chronic pulmonary arterial hypertension, the distribution of pulmonary blood volume was also abnormally uniform. There was, however, no indication that overall intrapulmonary blood volume was substantially different from normal subjects. The abnormally uniform distribution of pulmonary blood volume can be explained by recruitment and/or dilatation of vascular beds. Intrapulmonary blood volume appears to be increased in patients with intracardiac, left-to-right shunts. With the development of pulmonary hypertension, intrapulmonary blood volume falls, which may be explained by reactive changes in the vasculature and/or obliteration of capillaries

  20. The determination of blood volume in horses using stable isotope 50Cr

    International Nuclear Information System (INIS)

    Ito, Nobuhiko; Kunugiyama, Iwao; Tanaka, Masayoshi; Inoue, Megumi; Furukawa, Yoshinori; Hiraga, Atsushi; Yamanobe, Akira; Kubo, Katsuyoshi.

    1991-01-01

    A method using stable isotope 50 Cr was presented to determine equine blood volumes accurately in the field. The erythrocyte labelled with 50 Cr was injected intravenously, then small amount of blood was collected at regular intervals, and the erythrocyte volume was measured from dilution rate of 50 Cr. A blood volume was calculated from the erythrocyte volume and the packed cell volume (PCV). The present results suggested that the optimum time of collecting blood at rest was 2 h after injection of tagged blood. The red cell volumes and the total blood volumes of fifteen thoroughbred horses measured by the 50 Cr method were 46.6±9.9 and 133±17 ml/kg body weight, respectively. The mean red cell volume of stallion was larger than mare (t-test, p<0.05), and three was no significant difference in the blood volume. (author)

  1. The determination of blood volume in horses using stable isotope sup 50 Cr

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Nobuhiko; Kunugiyama, Iwao; Tanaka, Masayoshi; Inoue, Megumi; Furukawa, Yoshinori (Kitasato Univ., Towada, Aomori (Japan). School of Veterinary Medicine and Animal Sciences); Hiraga, Atsushi; Yamanobe, Akira; Kubo, Katsuyoshi

    1991-05-01

    A method using stable isotope {sup 50}Cr was presented to determine equine blood volumes accurately in the field. The erythrocyte labelled with {sup 50}Cr was injected intravenously, then small amount of blood was collected at regular intervals, and the erythrocyte volume was measured from dilution rate of {sup 50}Cr. A blood volume was calculated from the erythrocyte volume and the packed cell volume (PCV). The present results suggested that the optimum time of collecting blood at rest was 2 h after injection of tagged blood. The red cell volumes and the total blood volumes of fifteen thoroughbred horses measured by the {sup 50}Cr method were 46.6+-9.9 and 133+-17 ml/kg body weight, respectively. The mean red cell volume of stallion was larger than mare (t-test, p<0.05), and three was no significant difference in the blood volume. (author).

  2. Orthostatic leg blood volume changes assessed by near-infrared spectroscopy

    DEFF Research Database (Denmark)

    Truijen, J; Kim, Y S; Krediet, C T P

    2012-01-01

    posture, volume accumulation in small blood vessels contributes significantly to the total fluid volume accumulated in the legs. Considering that near-infrared spectroscopy (NIRS) tracks postural blood volume changes within the small blood vessels of the lower leg, we evaluated the NIRS-determined changes......-linear accumulation of blood volume in the small vessels of the leg, with an initial fast phase followed by a more gradual increase at least partly contributing to the relocation of fluid during orthostatic stress....

  3. Colloid volume loading does not mitigate decreases in central blood volume during simulated hemorrhage while heat stressed

    DEFF Research Database (Denmark)

    Crandall, Craig G; Wilson, Thad E; Marving, Jens

    2012-01-01

    attenuates the reduction in regional blood volumes during a simulated hemorrhagic challenge imposed via lower-body negative pressure (LBNP). Seven subjects underwent 30 mmHg LBNP while normothermic, during passive heat stress (increased internal temperature ~1°C), and while continuing to be heated after...... intravenous colloid volume loading (11 ml/kg). Relative changes in torso and regional blood volumes were determined by gamma camera imaging with technetium-99m labeled erythrocytes. Heat stress reduced blood volume in all regions (ranging from 7 to 16%), while subsequent volume loading returned those values...... to normothermic levels. While normothermic, LBNP reduced blood volume in all regions (torso: 22±8%; heart: 18±6%; spleen: 15±8%). During LBNP while heat stressed, the reductions in blood volume in each region were markedly greater when compared to LBNP while normothermic (torso: 73±2%; heart: 72±3%; spleen: 72...

  4. Blood volume studies in chronic renal failure using radioactive 51Cr

    International Nuclear Information System (INIS)

    Chadda, V.S.; Mehta, S.R.; Mathur, D.

    1975-01-01

    Estimation of blood volume was carried out in 20 healthy subjects and in 25 patients suffering from chronic renal failure using radioactive 51 Cr. A detailed history, physical examination and investigations were also undertaken. On statistical evaluation, the red cell volume was diminished significantly in males and females but rise in blood volume was insignificant. Plasma volume was raised significantly in females but was insignificant in males. The reduction in red cell volume is due to reduced red cell mass because of chronic renal disease. Plasma volume may be elevated in order to compensate for decreased red cell volume. The variability in these two parameters results in variable blood volume. (author)

  5. [Blood plasma volume dynamics in monkeys during immersion].

    Science.gov (United States)

    Krotov, V P; Burkovskaia, T E; Dotsenko, M A; Gordeev, Iu V; Nosovskiĭ, A M; Chel'naia, N A

    2004-01-01

    Dynamics of blood plasma volume (PV) was studied with indirect methods (hematocrit count, hemoglobin, total protein and high-molecular protein) during 9-d immersion of monkeys Macaca mulatta. The animals were donned in waterproof suits, motor restrained in space seat liners and immersed down to the xiphisternum. Two monkeys were immersed in the bath at one time. The suits were changed every day under ketamine (10 mg/kg of body mass). There were two groups with 12 animals in each. The first group was kept in the bath 3 days and the second--9 days. Prior to the experiment, the animals had been trained to stay in the seat liner put down into the dry bath. It was shown that already two days of exposure to the hydrostatic forces (approximately 15 mm Hg) and absence of negative pressure breathing reduced PV by 18-20% on the average in all animals. Subsequent PV dynamics was individual by character; however, PV deficit persisted during 4 days of immersion in the whole group. In this period, albumin filtration was increased significantly, whereas high-molecular protein filtration was increased to a less degree. During the remaining days in immersion PV regained normal values. Ten days of readaptation (reclined positioning of monkeys brought back into cage) raised VP beyond baseline values. This phenomenon can be attributed to the necessity to provide appropriate venous return and sufficient blood supply of organs and tissues following extension of blood vessels capacity.

  6. Altitude Acclimatization and Blood Volume: Effects of Exogenous Erythrocyte Volume Expansion

    National Research Council Canada - National Science Library

    Sawka, M

    1996-01-01

    ...: (a) altitude acclimatization effects on erythrocyte volume and plasma volume; (b) if exogenous erythrocyte volume expansion alters subsequent erythrocyte volume and plasma volume adaptations; (c...

  7. Resistance exercise with different volumes: blood pressure response and forearm blood flow in the hypertensive elderly

    Directory of Open Access Journals (Sweden)

    Brito AF

    2014-12-01

    Full Text Available Aline de Freitas Brito,1 Caio Victor Coutinho de Oliveira,2 Maria do Socorro Brasileiro-Santos,1 Amilton da Cruz Santos1 1Physical Education Department, 2Research Laboratory for Physical Training Applied to Performance and Health, Federal University of Paraíba, João Pessoa, Brazil Background: The purpose of this study was to evaluate the effect of two sessions of resistance exercise with different volumes on post-exercise hypotension, forearm blood flow, and forearm vascular resistance in hypertensive elderly subjects.Methods: The study was conducted with ten hypertensive elderly (65±3 years, 28.7±3 kg/m2 subjected to three experimental sessions, ie, a control session, exercise with a set (S1, and exercise with three sets (S3. For each session, the subjects were evaluated before and after intervention. In the pre-intervention period, blood pressure, forearm blood flow, and forearm vascular resistance were measured after 10 minutes of rest in the supine position. Thereafter, the subjects were taken to the gym to perform their exercise sessions or remained at rest during the same time period. Both S1 and S3 comprised a set of ten repetitions of ten exercises, with an interval of 90 seconds between exercises. Subsequently, the measurements were again performed at 10, 30, 50, 70, and 90 minutes of recovery (post-intervention in the supine position.Results: Post-exercise hypotension was greater in S3 than in S1 (systolic blood pressure, −26.5±4.2 mmHg versus −17.9±4.7 mmHg; diastolic blood pressure, −13.8±4.9 mmHg versus −7.7±5 mmHg, P<0.05. Similarly, forearm blood flow and forearm vascular resistance changed significantly in both sessions with an increase and decrease, respectively, that was more evident in S3 than in S1 (P<0.05.Conclusion: Resistance exercises with higher volume were more effective in causing post-exercise hypotension, being accompanied by an increase in forearm blood flow and a reduction of forearm vascular

  8. Blood volume, blood pressure and total body sodium: internal signalling and output control

    DEFF Research Database (Denmark)

    Bie, P

    2009-01-01

    Total body sodium and arterial blood pressure (ABP) are mutually dependent variables regulated by complex control systems. This review addresses the role of ABP in the normal control of sodium excretion (NaEx), and the physiological control of renin secretion. NaEx is a pivotal determinant of ABP......, and under experimental conditions, ABP is a powerful, independent controller of NaEx. Blood volume is a function of dietary salt intake; however, ABP is not, at least not in steady states. A transient increase in ABP after a step-up in sodium intake could provide a causal relationship between ABP...... and the regulation of NaEx via a hypothetical integrative control system. However, recent data show that subtle sodium loading (simulating salty meals) causes robust natriuresis without changes in ABP. Changes in ABP are not necessary for natriuresis. Normal sodium excretion is not regulated by pressure. Plasma...

  9. Effects of transjugular intrahepatic portosystemic shunt (TIPS) on blood volume distribution in patients with cirrhosis

    DEFF Research Database (Denmark)

    Busk, Troels M; Bendtsen, Flemming; Henriksen, Jens H

    2017-01-01

    increased (+22%, prestores central hypovolaemia......BACKGROUND: Cirrhosis is accompanied by portal hypertension with splanchnic and systemic arterial vasodilation, and central hypovolaemia. A transjugular intrahepatic portosystemic shunt (TIPS) alleviates portal hypertension, but also causes major haemodynamic changes. AIMS: To investigate effects...... catheterization. Central and arterial blood volume (CBV) and cardiac output (CO) were determined with indicator dilution technique. RESULTS: After TIPS, the thoracic blood volume increased (+10.4% of total blood volume (TBV), p

  10. Effects of passive heating on central blood volume and ventricular dimensions in humans

    DEFF Research Database (Denmark)

    Crandall, C.G.; Wilson, T.E.; Marving, J.

    2008-01-01

    Mixed findings regarding the effects of whole-body heat stress on central blood volume have been reported. This study evaluated the hypothesis that heat stress reduces central blood volume and alters blood volume distribution. Ten healthy experimental and seven healthy time control (i.e. non-heat...... stressed) subjects participated in this protocol. Changes in regional blood volume during heat stress and time control were estimated using technetium-99m labelled autologous red blood cells and gamma camera imaging. Whole-body heating increased internal temperature (> 1.0 degrees C), cutaneous vascular...... conductance (approximately fivefold), and heart rate (52 +/- 2 to 93 +/- 4 beats min(-1)), while reducing central venous pressure (5.5 +/- 07 to 0.2 +/- 0.6 mmHg) accompanied by minor decreases in mean arterial pressure (all P heat stress reduced the blood volume of the heart (18 +/- 2%), heart...

  11. The effect of glycerol on regional cerebral blood flow, blood volume and oxygen metabolism

    International Nuclear Information System (INIS)

    Ishikawa, Masatsune; Kikuchi, Haruhiko; Nagata, Izumi; Yamagata, Sen; Taki, Waro; Kobayashi, Akira; Yonekura, Yoshiharu; Nishizawa, Sadahiko.

    1989-01-01

    Using positron emission tomography with 15 O-labelled CO 2 , O 2 and CO gases, the effects of glycerol on regional cerebral blood flow (CBF), blood volume (CBV) and oxygen metabolism (CMRO 2 ) were investigated in 6 patients with meningioma accompanying peritumoral brain edema. The same study was done in 5 normal volunteers. The changes of blood gases, hematocrit and hemoglobin were also examined. After a drip infusion of glycerol, the regional CBF increased not only in the peritumoral cortex and white matter but also in the intact cortex and white matter on the contralateral side. The increase of CBF was extensive and substantially there were no regional differences. In contrast, the changes of CMRO 2 were not significant. This was derived from the increase in oxygen extraction fraction throughout extensive areas including the peritumoral area. There were no changes in CBV. Hematocrit and hemoglobin decreased to a small degree. In the normal volunteers, the same findings were noted. Thus, glycerol increases the functional reserve for cerebral oxygen metabolism, not only in the peritumoral regions but also in the intact regions. The effects of glycerol on hemodynamics and metabolism were discussed with reference to some differences from mannitol. (author)

  12. Plasma and blood volume in the calf from birth till 90 days of age

    International Nuclear Information System (INIS)

    Moellerberg, L.; Ekman, L.; Jacobsson, S.-O.

    1975-01-01

    Determinations of plasma volume were made of 9 clinically healthy Swedish Red and White calves from birth to 90 days of age by means of the isotop dilution technique. Commercially available 131 I labelled human serum albumin was used. Calculation of the total blood volume was based on the plasma volume and packed cell volume. The plasma and blood volumes increased per kg body weight in average 17 and 14 percent respectively from directly after birth to 24 hrs. old. From 1 to 90 days of age the plasma and blood volume fell steadily per kg body weight. Plasma volume expressed as a percentage of body weight was 5.3 percent at birth, 6.5 percent at 1 day old, and 4.9 percent at 90 days old. Corresponding values for blood were 8.4, 9.3 and 7.0 percent. (author)

  13. Whole body and tissue blood volumes of two strains of rainbow trout (Oncorhynchus mykiss)

    Science.gov (United States)

    Gingerich, W.H.; Pityer, R.A.; Rach, J.J.

    1990-01-01

    1. Estimates of apparent packed cell, plasma and total blood volumes for the whole body and for 13 selected tissues were compared between Kamloops and Wytheville strains of rainbow trout (Oncorhynchus mykiss) by the simultaneous injection of two vascular tracers, radiolabeled trout erythrocytes (51Cr-RBC) and radioiodated bovine serum albumin (125I-BSA).2. Whole body total blood volume, plasma volume and packed cell volume were slightly, but not significantly greater in the Wytheville trout, whereas, the apparent plasma volumes and total blood volumes in 4 of 13 tissues were significantly greater in the Kamloops strain.3. Differences were most pronounced in highly perfused organs, such as the liver and kidney and in organs of digestion such as the stomach and intestines.4. Differences in blood volumes between the two strains may be related to the greater permeability of the vascular membranes in the Kamloops strain fish.

  14. Blood volume measurement with indocyanine green pulse spectrophotometry: dose and site of dye administration

    NARCIS (Netherlands)

    Germans, Menno R.; de Witt Hamer, Philip C.; van Boven, Leonard J.; Zwinderman, Koos A. H.; Bouma, Gerrit J.

    2010-01-01

    (1) To determine the optimal administration site and dose of indocyanine green (ICG) for blood volume measurement using pulse spectrophotometry, (2) to assess the variation in repeated blood volume measurements for patients after subarachnoid hemorrhage and (3) to evaluate the safety and efficacy of

  15. Blood, blood compounds and cell cultures irradiation in clinical radiotherapy equipment: studies on ideal volume and dose

    International Nuclear Information System (INIS)

    Fernandes, Marco Antonio R.; Pereira, Adelino Jose; Novaes, Paulo Eduardo R.S.

    1995-01-01

    The authors present the technic and equipment used by the Physical Radiologic Service of Radiation Therapy Department of A.C. Camargo Hospital to irradiate blood and blood compounds. The practical routine is illustrated. The results from others Institutions are presented, discussing about the homogeneity of dose of 2000 to 3500 c Gy to all target volume, sufficient to neutralize cells responsible by graft-versus-host disease from blood transfusions. (author). 6 refs., 2 figs., 1 tab

  16. Differential effects of lower body negative pressure and upright tilt on splanchnic blood volume

    Science.gov (United States)

    Taneja, Indu; Moran, Christopher; Medow, Marvin S.; Glover, June L.; Montgomery, Leslie D.; Stewart, Julian M.

    2015-01-01

    Upright posture and lower body negative pressure (LBNP) both induce reductions in central blood volume. However, regional circulatory responses to postural changes and LBNP may differ. Therefore, we studied regional blood flow and blood volume changes in 10 healthy subjects undergoing graded lower-body negative pressure (−10 to −50 mmHg) and 8 subjects undergoing incremental head-up tilt (HUT; 20°, 40°, and 70°) on separate days. We continuously measured blood pressure (BP), heart rate, and regional blood volumes and blood flows in the thoracic, splanchnic, pelvic, and leg segments by impedance plethysmography and calculated regional arterial resistances. Neither LBNP nor HUT altered systolic BP, whereas pulse pressure decreased significantly. Blood flow decreased in all segments, whereas peripheral resistances uniformly and significantly increased with both HUT and LBNP. Thoracic volume decreased while pelvic and leg volumes increased with HUT and LBNP. However, splanchnic volume changes were directionally opposite with stepwise decreases in splanchnic volume with LBNP and stepwise increases in splanchnic volume during HUT. Splanchnic emptying in LBNP models regional vascular changes during hemorrhage. Splanchnic filling may limit the ability of the splanchnic bed to respond to thoracic hypovolemia during upright posture. PMID:17085534

  17. Blood cell labeling with technetium-99m. II. Measurement of circulating blood volume by sup(99m)Tc-labeled red blood cells

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, T; Yoshida, H; Matsuda, S; Kimura, H; Miura, N [Fukushima Medical Coll. (Japan)

    1978-02-01

    Using a labeling method with sup(99m)Tc-pertechnetate to red blood cells (RBC), circulating blood volume was measured in comparison with that from /sup 51/Cr-labeled RBC method. The technique is easier than already published methods, because CIS kit for sup(99m)Tc-RBC labeling (TCK-11) became to be available recently. Two mls of ACD-anticoagulated blood were withdrawn and 0.5 ml of reducing reagent prepared just before use was added to blood, waiting 5 minutes and discarding the serum after centrifugation, then adding 100 ..mu..Ci of sup(99m)Tc. After washing the labeled cells by isotonic saline, cells were re-suspended in 10 ml of saline and injected to the subject. Blood specimen was obtained 10, 30, 60 and 120 minutes after infusion and blood volume was calculated by the usual way. Circulating blood volume by sup(99m)Tc was well correlated with that by /sup 51/Cr (=0.98, p 0.01), however, the value calculated from sup(99m)Tc were 4.8 percent higher than those by /sup 51/Cr, which suggested the elution of sup(99m)Tc from labeled RBC. sup(99m)Tc method has the advantages that higher radioactivity can be obtained in small amount of blood, which is useful in the determination of blood volume in children or in small animals in the laboratory. The measurement of blood volume of the mouse was done by using sup(99m)Tc method. The results were 1.70 +- 0.06 ml (6.35 +- 0.18%/gm), which coincided with the values reported previously. Because of it's short half life and low radiation dosage to the patients, sup(99m)Tc method will be recommended in the field of pediatrics or in patients with polycythemia or congestive heart failure, who are requested the repeated measurement of blood volume.

  18. Plasma volume changes during hypoglycaemia: the effect of arterial blood sampling

    DEFF Research Database (Denmark)

    Hilsted, J; Bendtsen, Flemming; Christensen, N J

    1990-01-01

    To investigate whether previously reported changes in venous blood volume and composition induced by acute hypoglycaemia in humans are representative for the entire body we measured erythrocyte 51Cr content, haematocrit, plasma volume, intravascular albumin content and transcapillary escape rate...... hypoglycaemia. The magnitude of the changes in arterial and venous blood were not significantly different. These results indicate that the above changes in blood volume and composition are whole-body phenomena: furthermore, the major part of the changes are likely to occur in tissues other than upper extremity...... of albumin in arterial and venous blood in seven healthy subjects before and during insulin-induced hypoglycaemia. In both vascular sites blood 51Cr content and the haematocrit increased, plasma volume and intravascular albumin content decreased and the transcapillary escape rate of albumin increased during...

  19. SPECT measurements of cerebral blood volume before and after acetazolamide in occlusive cerebrovascular diseases

    International Nuclear Information System (INIS)

    Inoue, Yusuke; Momose, Toshimitsu; Machida, Kikuo; Honda, Norinari; Nishikawa, Junichi; Sasaki, Yasuhito.

    1994-01-01

    Cerebral blood volume before and after acetazolamide was measured by SPECT to evaluate cerebral vasodilatory capacity in eight patients with cerebrovascular disease and five control subjects. Two SPECT measurements were performed serially, and acetazolamide was administered between them. The ratio of increase in hemispheric blood volume was calculated, and it was compared with the results of cerebral blood flow and cerebral blood volume measurements. A cerebral vasodilatory capacity map, the image after acetazolamide minus the baseline image, was also produced. Acetazolamide increased hemispheric blood volume in all subjects. The ratio of increase was lower in the involved hemispheres of the patients with unilateral carotid disease than in the uninvolved hemispheres of the patients and control subjects. The ratio of concordance with blood flow and blood volume measurements was approximated at 80%. Cerebral vasodilatory capacity mapping revealed three defects compatible with the clinical data. SPECT measurements of cerebral blood volume after acetazolamide can be performed following baseline SPECT with no additional radiotracer, and may be helpful to assess hemodynamic status. (author)

  20. Decreased right heart blood volume determined by magnetic resonance imaging: evidence of central underfilling in cirrhosis

    DEFF Research Database (Denmark)

    Møller, S; Søndergaard, L; Møgelvang, J

    1995-01-01

    mL, NS), and left atrial volume (70 vs. 57 mL, P = .08) were normal or slightly increased. The right ejection fraction (68% vs. 53%, P fraction was slightly reduced (61% vs. 69%, NS). The central and arterial blood volume (CBV), assessed......Whether the central blood volume is reduced or expanded in cirrhosis is still under debate. Accordingly, the current study was undertaken to assess the volume of the heart cavities. Ten cirrhotic patients and matched controls had their right and left ventricular end-diastolic volumes (RVDV and LVDV...... as the cardiac output (CO) multiplied by the central circulation time, was significantly decreased (1.47 vs. 1.81 L, P blood volume (4.43 vs. 3.64 L, P

  1. Pulmonary blood volume and transit time in cirrhosis: relation to lung function

    DEFF Research Database (Denmark)

    Møller, Søren; Burchardt, H; Øgard, CG

    2006-01-01

    BACKGROUND/AIMS: In cirrhosis a systemic vasodilatation leads to an abnormal distribution of the blood volume with a contracted central blood volume. In addition, the patients have a ventilation/perfusion imbalance with a low diffusing capacity. As the size of the pulmonary blood volume (PBV) has...... not been determined separately we assessed PBV and pulmonary transit time (PTT) in relation to lung function in patients with cirrhosis and in controls. METHODS: Pulmonary and cardiac haemodynamics and transit times were determined by radionuclide techniques in 22 patients with alcoholic cirrhosis......, in the controls, Pvolume...

  2. Global and regional changes of cardiopulmonary blood volume under continuous work load

    International Nuclear Information System (INIS)

    Hoeck, A.; Schuerch, P.; Freundlieb, C.; Vyska, K.; Kunz, N.; Feinendegen, L.E.; Hollmann, W.

    1980-01-01

    The present study describes a method for the continuous determination of global and regional stress-induced alterations of cardiopulmonary blood volumes in normals, trained athletes and patients with latent cardiac insufficiency. In contrast to normals and athletes there is an increase of the total cardiac blood volume in the cardiac patients. There are also significant differences in blood volume changes of the left lung between normals and athletes on the one hand and the cardiac patients on the other. The method is simple and non-hazardous; it permits the observation of the obviously different adaptation of the cardiopulmonary system during exercise in normals, athletes and cardiac patients. (orig.) [de

  3. Plasma volume changes during hypoglycaemia: the effect of arterial blood sampling

    DEFF Research Database (Denmark)

    Hilsted, J; Bendtsen, F; Christensen, N J

    1990-01-01

    To investigate whether previously reported changes in venous blood volume and composition induced by acute hypoglycaemia in humans are representative for the entire body we measured erythrocyte 51Cr content, haematocrit, plasma volume, intravascular albumin content and transcapillary escape rate...... hypoglycaemia. The magnitude of the changes in arterial and venous blood were not significantly different. These results indicate that the above changes in blood volume and composition are whole-body phenomena: furthermore, the major part of the changes are likely to occur in tissues other than upper extremity...

  4. C-arm flat detector computed tomography parenchymal blood volume imaging: the nature of parenchymal blood volume parameter and the feasibility of parenchymal blood volume imaging in aneurysmal subarachnoid haemorrhage patients

    International Nuclear Information System (INIS)

    Kamran, Mudassar; Byrne, James V.

    2015-01-01

    C-arm flat detector computed tomography (FDCT) parenchymal blood volume (PBV) measurements allow assessment of cerebral haemodynamics in the neurointerventional suite. This paper explores the feasibility of C-arm computed tomography (CT) PBV imaging and the relationship between the C-arm CT PBV and the MR-PWI-derived cerebral blood volume (CBV) and cerebral blood flow (CBF) parameters in aneurysmal subarachnoid haemorrhage (SAH) patients developing delayed cerebral ischemia (DCI). Twenty-six patients with DCI following aneurysmal SAH underwent a research C-arm CT PBV scan using a biplane angiography system and contemporaneous MR-PWI scan as part of a prospective study. Quantitative whole-brain atlas-based volume-of-interest analysis in conjunction with Pearson correlation and Bland-Altman tests was performed to explore the agreement between C-arm CT PBV and MR-derived CBV and CBF measurements. All patients received medical management, while eight patients (31 %) underwent selective intra-arterial chemical angioplasty. Colour-coded C-arm CT PBV maps were 91 % sensitive and 100 % specific in detecting the perfusion abnormalities. C-arm CT rPBV demonstrated good agreement and strong correlation with both MR-rCBV and MR-rCBF measurements; the agreement and correlation were stronger for MR-rCBF relative to MR-rCBV and improved for C-arm CT PBV versus the geometric mean of MR-rCBV and MR-rCBF. Analysis of weighted means showed that the C-arm CT PBV has a preferential blood flow weighting (∼60 % blood flow and ∼40 % blood volume weighting). C-arm CT PBV imaging is feasible in DCI following aneurysmal SAH. PBV is a composite perfusion parameter incorporating both blood flow and blood volume weightings. That PBV has preferential (∼60 %) blood flow weighting is an important finding, which is of clinical significance when interpreting the C-arm CT PBV maps, particularly in the setting of acute brain ischemia. (orig.)

  5. C-arm flat detector computed tomography parenchymal blood volume imaging: the nature of parenchymal blood volume parameter and the feasibility of parenchymal blood volume imaging in aneurysmal subarachnoid haemorrhage patients

    Energy Technology Data Exchange (ETDEWEB)

    Kamran, Mudassar; Byrne, James V. [University of Oxford, Nuffield Department of Surgical Sciences, Oxford (United Kingdom)

    2015-09-15

    C-arm flat detector computed tomography (FDCT) parenchymal blood volume (PBV) measurements allow assessment of cerebral haemodynamics in the neurointerventional suite. This paper explores the feasibility of C-arm computed tomography (CT) PBV imaging and the relationship between the C-arm CT PBV and the MR-PWI-derived cerebral blood volume (CBV) and cerebral blood flow (CBF) parameters in aneurysmal subarachnoid haemorrhage (SAH) patients developing delayed cerebral ischemia (DCI). Twenty-six patients with DCI following aneurysmal SAH underwent a research C-arm CT PBV scan using a biplane angiography system and contemporaneous MR-PWI scan as part of a prospective study. Quantitative whole-brain atlas-based volume-of-interest analysis in conjunction with Pearson correlation and Bland-Altman tests was performed to explore the agreement between C-arm CT PBV and MR-derived CBV and CBF measurements. All patients received medical management, while eight patients (31 %) underwent selective intra-arterial chemical angioplasty. Colour-coded C-arm CT PBV maps were 91 % sensitive and 100 % specific in detecting the perfusion abnormalities. C-arm CT rPBV demonstrated good agreement and strong correlation with both MR-rCBV and MR-rCBF measurements; the agreement and correlation were stronger for MR-rCBF relative to MR-rCBV and improved for C-arm CT PBV versus the geometric mean of MR-rCBV and MR-rCBF. Analysis of weighted means showed that the C-arm CT PBV has a preferential blood flow weighting (∼60 % blood flow and ∼40 % blood volume weighting). C-arm CT PBV imaging is feasible in DCI following aneurysmal SAH. PBV is a composite perfusion parameter incorporating both blood flow and blood volume weightings. That PBV has preferential (∼60 %) blood flow weighting is an important finding, which is of clinical significance when interpreting the C-arm CT PBV maps, particularly in the setting of acute brain ischemia. (orig.)

  6. The effect of chronic erythrocytic polycythemia and high altitude upon plasma and blood volumes.

    Science.gov (United States)

    Burton, R. R.; Smith, A. H.

    1972-01-01

    Comparison of two kinds of physiological chronic erythrocytic polycythemias in order to differentiate the specific effect of erythrocytic polycythemia from the general effects of high altitude upon the plasma volume. The two kinds were produced hormonally in female chickens, at sea level, or by protracted high-altitude exposures. It appears that the vascular system of the body may account for an increase in red blood cell mass either by reduction in plasma volume, or by no change in plasma volume, resulting in differential changes in total blood volumes.

  7. Changes in circulating blood volume after infusion of hydroxyethyl starch 6% in critically ill patients

    DEFF Research Database (Denmark)

    Christensen, P; Andersson, J; Rasmussen, S E

    2001-01-01

    The cardiovascular response to a volume challenge with hydroxyethyl starch (HES) (200/0.5) 6% depends on the relation between the volume of HES 6% infused and the expansion of the blood volume in critically ill patients. However, only relatively limited data exist on the plasma expanding effect...... of infusion of HES 6% in critically ill patients. The purpose of the study was to evaluate the variation in the expansion of the circulating blood volume (CBV) in critically ill patients after infusion of 500 ml of colloid (HES (200/0.5) 6%) using the carbon monoxide method....

  8. Very Low Cerebral Blood Volume Predicts Parenchymal Hematoma in Acute Ischemic Stroke

    DEFF Research Database (Denmark)

    Hermitte, Laure; Cho, Tae-Hee; Ozenne, Brice

    2013-01-01

    BACKGROUND AND PURPOSE: Parenchymal hematoma (PH) may worsen the outcome of patients with stroke. The aim of our study was to confirm the relationship between the volume of very low cerebral blood volume (CBV) and PH using a European multicenter database (I-KNOW). A secondary objective was to exp......BACKGROUND AND PURPOSE: Parenchymal hematoma (PH) may worsen the outcome of patients with stroke. The aim of our study was to confirm the relationship between the volume of very low cerebral blood volume (CBV) and PH using a European multicenter database (I-KNOW). A secondary objective...

  9. [Blood volume for biochemistry determinations--laboratory needs and everyday practice].

    Science.gov (United States)

    Sztefko, Krystyna; Mamica, Katarzyna; Bugajska, Jolanta; Maziarz, Barbara; Tomasik, Przemysław

    2014-01-01

    Blood loss due to diagnostic phlebotomy jest a very serious problem, especially for newborn, infants and critically ill patients on intensive care units. Although single blood loss can be easily tolerated in adults, in small babies and in patients who are frequently monitored based on laboratory tests iatrogenic anaemia can occur. To evaluate the blood volume drawn for routine biochemistry tests in relation to patient age and the number of parameters requested. Blood volume drawn for routine biochemistry measurements from patients hospitalized in University Children's Hospital (N = 2980, children age from one day to 18 years) and in University Hospital (N = 859, adults, aged > 1.8 years) in Cracow has been analyzed. Blood volume was calculated based on regular tube diameter and blood heights in the tube. In case of microvettes the blood volume was 0.2 ml. Statistical analysis has been performed by using PRISM 5.0. The statistical significance was set at p nurses and doctors should include the information about current laboratory automation and methods miniaturization; 2) The amount of blood volume needed by laboratory for the requested number of tests should always be taken into account when diagnostic phlebotomy is necessary.

  10. Extracellular space, blood volume, and the early dumping syndrome after total gastrectomy

    Energy Technology Data Exchange (ETDEWEB)

    Miholic, J.; Reilmann, L.; Meyer, H.J.; Koerber, H.K.; Kotzerke, J.; Hecker, H. (Medzinische Hochschule Hannover (Germany, F.R.))

    1990-10-01

    Extracellular space and blood volume were measured using 82Br dilution and 51Cr-tagged erythrocytes in 24 tumor-free patients after total gastrectomy. Eleven of the patients suffered from early dumping. Age, blood volume, and extracellular space were significantly smaller in dumpers (P less than 0.05). The dumping score could be predicted by a multiple regression model considering blood volume per lean body mass and extracellular space (r = 0.637; P = 0.0039). Rapid (t1/2 less than 360 seconds) emptying of the gastric substitute, assessed using a 99Tc-labeled solid test meal, was significantly associated with dumping in addition to extracellular space and blood volume (r = 0.876; P = 0.0018). Both rapid emptying and a narrow extracellular space seem to contribute to the early dumping syndrome.

  11. Blood Volume and Other Hematologic Values in Young Elephant Seals (Mirounga angustirostris)

    National Research Council Canada - National Science Library

    Simpson, John G; Gilmartin, William G; Ridgway, Sam H

    1970-01-01

    ... (Mirounga angustirostris) by a method that could be accurate to 2 percent. The blood volumes of 7 young northern elephant seals were analyzed using a dilution of radioactive iodinated human serum albumin...

  12. Determination of left ventricular volume using gated blood pool tomography comparison with contrast ventriculography

    International Nuclear Information System (INIS)

    Lu Ping; Mo Lijun; Liu Xiujie

    1992-01-01

    48 patients with cardiac disease were studied with gated blood pool tomography to determine left ventricular volume at end diastole, end-systole and ejection fraction. The volumes were calculated from serial short-axis tomograms by multiplying the number of pixels and the known volume of each pixel. Excellent correlation was found between blood pool tomography and contrast ventriculographic volume. At end-diastole, r = 0.91 (P < 0.01); at end-systole, r = 0.95 (P < 0.01); for left ventricular ejection fraction, r 0.90 (P < 0.01). The results suggest that gated blood pool tomography is a promising noninvasive and direct method for measuring left ventricular volume

  13. Volume of blood suctioned during vacuum-assisted breast biopsy predicts later hematoma formation

    Directory of Open Access Journals (Sweden)

    Panopoulou Effrosyni

    2010-03-01

    Full Text Available Abstract Background To evaluate whether the volume of blood suctioned during vacuum-assisted breast biopsy (VABB is associated with hematoma formation and progression, patient's age and histology of the lesion. Findings 177 women underwent VABB according to standardized protocol. The volume of blood suctioned and hematoma formation were noted at the end of the procedure, as did the subsequent development and progression of hematoma. First- and second-order logistic regression was performed, where appropriate. Cases with hematoma presented with greater volume of blood suctioned (63.8 ± 44.7 cc vs. 17.2 ± 32.9 cc; p Conclusion The likelihood of hematoma is increasing along with increasing amount of blood suctioned, reaching a plateau approximately at 80 cc of blood lost.

  14. Computer simulation of preflight blood volume reduction as a countermeasure to fluid shifts in space flight

    Science.gov (United States)

    Simanonok, K. E.; Srinivasan, R.; Charles, J. B.

    1992-01-01

    Fluid shifts in weightlessness may cause a central volume expansion, activating reflexes to reduce the blood volume. Computer simulation was used to test the hypothesis that preadaptation of the blood volume prior to exposure to weightlessness could counteract the central volume expansion due to fluid shifts and thereby attenuate the circulatory and renal responses resulting in large losses of fluid from body water compartments. The Guyton Model of Fluid, Electrolyte, and Circulatory Regulation was modified to simulate the six degree head down tilt that is frequently use as an experimental analog of weightlessness in bedrest studies. Simulation results show that preadaptation of the blood volume by a procedure resembling a blood donation immediately before head down bedrest is beneficial in damping the physiologic responses to fluid shifts and reducing body fluid losses. After ten hours of head down tilt, blood volume after preadaptation is higher than control for 20 to 30 days of bedrest. Preadaptation also produces potentially beneficial higher extracellular volume and total body water for 20 to 30 days of bedrest.

  15. Cerebral blood volume measurement using radioactive carboxyhemoglobin and positron emission tomography. Chapter 26

    International Nuclear Information System (INIS)

    Kanno, Iwao; Murakami, Matsutaro; Miura, Shuichi; Iida, Hidehiro; Takahashi, Kazuhiro; Sasaki, Hiroshi; Uemura, Kazuo

    1988-01-01

    This paper aims to describe the technical basis for this simplest cerebral blood volume (CBV) measurement using CO-labelled red blood cells and PET and to clarify the error sources in the technique which will become critical when we perform studies on physiological activation of CBV. 17 refs.; 6 figs.; 2 tabs

  16. Tranexamic Acid Reduced the Percent of Total Blood Volume Lost During Adolescent Idiopathic Scoliosis Surgery.

    Science.gov (United States)

    Jones, Kristen E; Butler, Elissa K; Barrack, Tara; Ledonio, Charles T; Forte, Mary L; Cohn, Claudia S; Polly, David W

    2017-01-01

    Multilevel posterior spine fusion is associated with significant intraoperative blood loss. Tranexamic acid is an antifibrinolytic agent that reduces intraoperative blood loss. The goal of this study was to compare the percent of total blood volume lost during posterior spinal fusion (PSF) with or without tranexamic acid in patients with adolescent idiopathic scoliosis (AIS). Thirty-six AIS patients underwent PSF in 2011-2014; the last half (n=18) received intraoperative tranexamic acid. We retrieved relevant demographic, hematologic, intraoperative and outcomes information from medical records. The primary outcome was the percent of total blood volume lost, calculated from estimates of intraoperative blood loss (numerator) and estimated total blood volume per patient (denominator, via Nadler's equations). Unadjusted outcomes were compared using standard statistical tests. Tranexamic acid and no-tranexamic acid groups were similar (all p>0.05) in mean age (16.1 vs. 15.2 years), sex (89% vs. 83% female), body mass index (22.2 vs. 20.2 kg/m2), preoperative hemoglobin (13.9 vs. 13.9 g/dl), mean spinal levels fused (10.5 vs. 9.6), osteotomies (1.6 vs. 0.9) and operative duration (6.1 hours, both). The percent of total blood volume lost (TBVL) was significantly lower in the tranexamic acid-treated vs. no-tranexamic acid group (median 8.23% vs. 14.30%, p = 0.032); percent TBVL per level fused was significantly lower with tranexamic acid than without it (1.1% vs. 1.8%, p=0.048). Estimated blood loss (milliliters) was similar across groups. Tranexamic acid significantly reduced the percentage of total blood volume lost versus no tranexamic acid in AIS patients who underwent PSF using a standardized blood loss measure.Level of Evidence: 3. Institutional Review Board status: This medical record chart review (minimal risk) study was approved by the University of Minnesota Institutional Review Board.

  17. Relation of mean platelet volume and red blood cell distribution width with epistaxis.

    Science.gov (United States)

    Kemal, Ozgur; Müderris, Togay; Sevil, Ergün; Kutlar, Gökhan

    2015-04-01

    Mean platelet volume is the measurement of the average size of platelets in the blood, and red blood cell distribution width is the variability of the size of red blood cells in circulation. This study aimed to investigate if there was any relationship between mean platelet volume, red blood cell distribution, and epistaxis. Prospective controlled trial. The study included 90 patients admitted to Ankara Atatürk Hospital and Samsun Medicana Hospital with complaints of recurrent epistaxis, and a control group of 90 healthy subjects. Blood samples were taken from all patients and control group subjects. Mean platelet volume and red blood cell distribution parameters were examined and compared between the two groups. The mean platelet volume levels were determined as 8.86 ± 0.1 in the control group and 8.36 ± 0.1 in the patient group. The difference between the two groups with respect to mean platelet volume was statistically significant (P epistaxis. These findings could be beneficial in new investigations into epistaxis mechanisms. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  18. Coxiella burnetii shedding by dairy cows.

    Science.gov (United States)

    Guatteo, Raphaël; Beaudeau, François; Joly, Alain; Seegers, Henri

    2007-01-01

    While shedding routes of Coxiella burnetii are identified, the characteristics of Coxiella shedding are still widely unknown, especially in dairy cattle. However, this information is crucial to assess the natural course of Coxiella burnetii infection within a herd and then to elaborate strategies to limit the risks of transmission between animals and to humans. The present study aimed at (i) describing the characteristics of Coxiella burnetii shedding by dairy cows (in milk, vaginal mucus, faeces) in five infected dairy herds, and at (ii) investigating the possible relationships between shedding patterns and serological responses. A total of 145 cows were included in a follow-up consisting of seven concomitant samplings of milk, vaginal mucus, faeces and blood (Day 0, D7, D14, D21, D28, D63, D90). Detection and quantification of Coxiella burnetii titres were performed in milk, vaginal mucus and faeces samples using real-time PCR assay, while antibodies against Coxiella were detected using an ELISA technique. For a given shedding route, and a given periodicity (weekly or monthly), cows were gathered into different shedding kinetic patterns according to the sequence of PCR responses. Distribution of estimated titres in Coxiella burnetii was described according to shedding kinetic patterns. Coxiella burnetii shedding was found scarcely and sporadically in faeces. Vaginal mucus shedding concerned almost 50% of the cows studied and was found intermittently or sporadically, depending on the periodicity considered. Almost 40% of cows were detected as milk shedders, with two predominant shedding patterns: persistent and sporadic, regardless of the sampling periodicity. Significantly higher estimated titres in Coxiella burnetii were observed in cows with persistent shedding patterns suggesting the existence of heavy shedder cows. These latter cows were mostly, persistently highly-seropositive, suggesting that repeated serological testings could be a reliable tool to screen

  19. Relative blood volume monitoring during hemodialysis in end stage renal disease patients.

    Science.gov (United States)

    Ion Titapiccolo, Jasmine; Ferrario, Manuela; Garzotto, Francesco; Cruz, Dinna; Moissl, Ulrich; Tetta, Ciro; Ronco, Claudio; Signorini, Maria G; Cerutti, Sergio

    2010-01-01

    A crucial point in the haemodialysis (HD) treatment is the reliable assessment of hydration status. An inadequate removed volume may lead to chronic fluid overload which can lead to hypertension, left ventricular hypertrophy and heart failure. Therefore, the estimation of the hydration state and the management of a well-tolerated water removal is an important challenge. This exploratory study aims at identifying new parameters obtained from continuous Blood Volume Monitoring (BVM) allowing a qualitative evaluation of hydration status for verifying the adequacy of HD setting parameters (e.g UFR, target dry weight). The percentage of blood volume reduction (BVR%) during HD was compared against a gold standard method for hydration status assessment. The slope of the first 30 minute of blood volume reduction (BVR) was proposed as a useful parameter to identify overhydrated patients.

  20. /sup 3/H-dextran method for measurements of the blood volume in the rat choroid

    Energy Technology Data Exchange (ETDEWEB)

    Matsusaka, T [Osaka Prefectural Center for Adult Diseases (Japan); Morimoto, K; Kikkawa, Y

    1980-01-01

    A new method was developed using /sup 3/H-dextran for measuring the blood volume in the choroid. Under pentobarbital-anesthesia, albino rats weighing 200 grams were perfused through the left ventricle with a 2.5 percent glutaraldehyde solution containing the radioactive dextran. The procedure allowed exchange of the choroidal blood with the /sup 3/H-dextran solution with a simultaneous fixation of the choroid. The blood volume in the choroid was calculated from the radioactivity count, which is estimated to be 1.690 x 10/sup -4/ ml per mg wet weight and 5.070 x 10/sup -4/ ml per mg dry weight. Epinephrine subconjunctivally injected diminished the blood volume in the choroid by 68 percent. Pretreatment with lidocaine almost nullified the effect of epinephrine. Applicability of this method to the analytical study of the choroidal circulation is discussed.

  1. 3H-dextran method for measurements of the blood volume in the rat choroid

    International Nuclear Information System (INIS)

    Matsusaka, Toshihiko; Morimoto, Kazuhiro; Kikkawa, Yoshizo.

    1980-01-01

    A new method was developed using 3 H-dextran for measuring the blood volume in the choroid. Under pentobarbital-anesthesia, albino rats weighing 200 grams were perfused through the left ventricle with a 2.5 percent glutaraldehyde solution containing the radioactive dextran. The procedure allowed exchange of the choroidal blood with the 3 H-dextran solution with a simultaneous fixation of the choroid. The blood volume in the choroid was calculated from the radioactivity count, which is estimated to be 1.690 x 10 -4 ml per mg wet weight and 5.070 x 10 -4 ml per mg dry weight. Epinephrine subconjunctivally injected diminished the blood volume in the choroid by 68 percent. Pretreatment with lidocaine almost nullified the effect of epinephrine. Applicability of this method to the analytical study of the choroidal circulation is discussed. (author)

  2. Scintigraphic method for evaluating reductions in local blood volumes in human extremities

    DEFF Research Database (Denmark)

    Blønd, L; Madsen, Jan Lysgård

    2000-01-01

    in the experiment. Evaluation of one versus two scintigraphic projections, trials for assessment of the reproducibility, a comparison of the scintigraphic method with a water-plethysmographic method and registration of the fractional reduction in blood volume caused by exsanguination as a result of simple elevation......% in the lower limb experiment and 6% in the upper limb experiment. We found a significant relation (r = 0.42, p = 0.018) between the results obtained by the scintigraphic method and the plethysmographic method. In fractions, a mean reduction in blood volume of 0.49+0.14 (2 SD) was found after 1 min of elevation......We introduce a new method for evaluating reductions in local blood volumes in extremities, based on the combined use of autologue injection of 99mTc-radiolabelled erythrocytes and clamping of the limb blood flow by the use of a tourniquet. Twenty-two healthy male volunteers participated...

  3. Volume-dependent hemodynamic effects of blood collection in canine donors - evaluation of 13% and 15% of total blood volume depletion

    Directory of Open Access Journals (Sweden)

    RUI R.F. FERREIRA

    2015-03-01

    Full Text Available Background: There is no consensus regarding the blood volume that could be safely donated by dogs, ranging from 11 to 25% of its total blood volume (TBV. No previous studies evaluated sedated donors.Aim: To evaluate the hemodynamic effects of blood collection from sedated and non-sedated dogs and to understand if such effects were volume-dependent.Materials and Methods: Fifty three donations of 13% of TBV and 20 donations of 15% TBV were performed in dogs sedated with diazepam and ketamine. Additionally, a total of 30 collections of 13% TBV and 20 collections of 15% TBV were performed in non-sedated dogs. Non-invasive arterial blood pressures and pulse rates were registered before and 15 min after donation. Results: Post-donation pulse rates increased significantly in both sedated groups, with higher differences in the 15% TBV collections. Systolic arterial pressures decreased significantly in these groups, while diastolic pressures increased significantly in 13% TBV donations. Non-sedated groups revealed a slight, but significant, SBP decrease. No clinical signs related to donations were registered.Conclusion: These results suggest that the collection of 15% TBV in sedated donors induces hemodynamic variations that may compromise the harmlessness of the procedure, while it seems to be a safe procedure in non-sedated dogs.

  4. Fluorescence Exclusion: A Simple Method to Assess Projected Surface, Volume and Morphology of Red Blood Cells Stored in Blood Bank

    Directory of Open Access Journals (Sweden)

    Camille Roussel

    2018-05-01

    Full Text Available Red blood cells (RBC ability to circulate is closely related to their surface area-to-volume ratio. A decrease in this ratio induces a decrease in RBC deformability that can lead to their retention and elimination in the spleen. We recently showed that a subpopulation of “small RBC” with reduced projected surface area accumulated upon storage in blood bank concentrates, but data on the volume of these altered RBC are lacking. So far, single cell measurement of RBC volume has remained a challenging task achieved by a few sophisticated methods some being subject to potential artifacts. We aimed to develop a reproducible and ergonomic method to assess simultaneously RBC volume and morphology at the single cell level. We adapted the fluorescence exclusion measurement of volume in nucleated cells to the measurement of RBC volume. This method requires no pre-treatment of the cell and can be performed in physiological or experimental buffer. In addition to RBC volume assessment, brightfield images enabling a precise definition of the morphology and the measurement of projected surface area can be generated simultaneously. We first verified that fluorescence exclusion is precise, reproducible and can quantify volume modifications following morphological changes induced by heating or incubation in non-physiological medium. We then used the method to characterize RBC stored for 42 days in SAG-M in blood bank conditions. Simultaneous determination of the volume, projected surface area and morphology allowed to evaluate the surface area-to-volume ratio of individual RBC upon storage. We observed a similar surface area-to-volume ratio in discocytes (D and echinocytes I (EI, which decreased in EII (7% and EIII (24%, sphero-echinocytes (SE; 41% and spherocytes (S; 47%. If RBC dimensions determine indeed the ability of RBC to cross the spleen, these modifications are expected to induce the rapid splenic entrapment of the most morphologically altered RBC

  5. Determination of the blood volume on young trotters with J131-HSA (RIHSA)

    International Nuclear Information System (INIS)

    Adamopoulou, B.

    1975-01-01

    We have examined the accuracy of our method of determining blood volume and its utility under field conditions on forty trotters of the same age. Furthermore we were interested in to what extent it is possible to conclude from the quantity of blood emitted by the corresponding blood reservoirs on the capacity of sport horses. The blood volume determination was carried out with J 131 -human-serum-albumin, after we had excluded the usability of Cr 51 by reason of radiological protection. Our results show that the methodical total error, which we had determined from four different controls is so low under field conditions that our method can be used in the field with highly evaltable results. The percentage of blood emitted by the reservoirs gives information only about the momentary capacity of a horse. It is not an objective measure for the future capacity of a growing horse for this is influenced by too many endogenic an exogenic factors. (orig.) [de

  6. Understanding the heterogeneity in volume overload and fluid distribution in decompensated heart failure is key to optimal volume management: role for blood volume quantitation.

    Science.gov (United States)

    Miller, Wayne L; Mullan, Brian P

    2014-06-01

    This study sought to quantitate total blood volume (TBV) in patients hospitalized for decompensated chronic heart failure (DCHF) and to determine the extent of volume overload, and the magnitude and distribution of blood volume and body water changes following diuretic therapy. The accurate assessment and management of volume overload in patients with DCHF remains problematic. TBV was measured by a radiolabeled-albumin dilution technique with intravascular volume, pre-to-post-diuretic therapy, evaluated at hospital admission and at discharge. Change in body weight in relation to quantitated TBV was used to determine interstitial volume contribution to total fluid loss. Twenty-six patients were prospectively evaluated. Two patients had normal TBV at admission. Twenty-four patients were hypervolemic with TBV (7.4 ± 1.6 liters) increased by +39 ± 22% (range, +9.5% to +107%) above the expected normal volume. With diuresis, TBV decreased marginally (+30 ± 16%). Body weight declined by 6.9 ± 5.2 kg, and fluid intake/fluid output was a net negative 8.4 ± 5.2 liters. Interstitial compartment fluid loss was calculated at 6.2 ± 4.0 liters, accounting for 85 ± 15% of the total fluid reduction. TBV analysis demonstrated a wide range in the extent of intravascular overload. Dismissal measurements revealed marginally reduced intravascular volume post-diuretic therapy despite large reductions in body weight. Mobilization of interstitial fluid to the intravascular compartment with diuresis accounted for this disparity. Intravascular volume, however, remained increased at dismissal. The extent, composition, and distribution of volume overload are highly variable in DCHF, and this variability needs to be taken into account in the approach to individualized therapy. TBV quantitation, particularly serial measurements, can facilitate informed volume management with respect to a goal of treating to euvolemia. Copyright © 2014 American College of Cardiology Foundation. Published

  7. Hemodynamic and ADH responses to central blood volume shifts in cardiac-denervated humans

    Science.gov (United States)

    Convertino, V. A.; Thompson, C. A.; Benjamin, B. A.; Keil, L. C.; Savin, W. M.; Gordon, E. P.; Haskell, W. L.; Schroeder, J. S.; Sandler, H.

    1990-01-01

    Hemodynamic responses and antidiuretic hormone (ADH) were measured during body position changes designed to induce blood volume shifts in ten cardiac transplant recipients to assess the contribution of cardiac and vascular volume receptors in the control of ADH secretion. Each subject underwent 15 min of a control period in the seated posture, then assumed a lying posture for 30 min at 6 deg head down tilt (HDT) followed by 20 min of seated recovery. Venous blood samples and cardiac dimensions (echocardiography) were taken at 0 and 15 min before HDT, 5, 15, and 30 min of HDT, and 5, 15, and 30 min of seated recovery. Blood samples were analyzed for hematocrit, plasma osmolality, plasma renin activity (PRA), and ADH. Resting plasma volume (PV) was measured by Evans blue dye and percent changes in PV during posture changes were calculated from changes in hematocrit. Heart rate (HR) and blood pressure (BP) were recorded every 2 min. Results indicate that cardiac volume receptors are not the only mechanism for the control of ADH release during acute blood volume shifts in man.

  8. Modelling merchantable volumes for uneven aged maritime pine (Pinus pinaster Aiton stands establi-shed by natural regeneration in the central Portugal

    Directory of Open Access Journals (Sweden)

    Cristina Alegria

    2013-12-01

    Full Text Available Uneven aged maritime pine stands established by natural regeneration have a great expression in Portugal. These stands being overstocked, as opposed to those established from plantations, provide straight and cylindrical tree boles and logs with less knots that makes them very suitable for certain industrial purposes. Therefore, the aim of this study was to fit a set of equations to predict total volume and merchantable volumes to any merchantable limit for uneven aged maritime pine stands established by natural regeneration in the central inland region of Portugal. Data were collected in 30 circular sampling plots of 500 m2 of area, on 1426 trees and 314 sample trees for volume assessment, corresponding to 2353 diameter/height mea-surements. A total height equation, a total volume equation, a volume ratio equation to any top height limit and a taper equation, over bark, were fitted. To select among the best models, several statistics were computed during model fitting and the independent validation procedure to evaluate model fitting, collinearity and prediction performances. A ranking index was used to support the final decision. The models selected were then fitted again using robust regression and weighted regression techniques, because studentized residuals distribution normality and homogeneity assumptions were not observed. This research showed that the models selected for these stands were not the same as those selected in previous studies for the species in this region, suggesting that these results may be due to the influence of stand density conditions on diameter and total height growth, and consequently, on stem form and volume. This set of equations will also be included as components in a single tree growth and yield model developed for these stands. 

  9. Measurement of regional extravascular lung density and of pulmonary blood volume with positron emitting isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Larock, M.P.; Quaglia, L.; Lamotte, D.; De Landsheere, C.; Del Fiore, G.; Chevigne, M.; Peters, J.M.; Rigo, P. (Universite de Liege (Belgium))

    1982-01-01

    Studies of pulmonary blood volume changes with exercise can be performed after labelling of the blood pool by /sup 11/CO inhalation. Positron transaxial tomography permits the quantitative study of density distribution of the chest and of the pulmonary blood volume. This paper represents our preliminary experience with these techniques on models and control patients. We have first verified the linearity of transmission for density distribution below one. The tomographic examination first records a transmission image, then an emission image on the same section. We next normalize emission and transmission values on a region of unit density corresponding to blood: then we substract the emission from the transmission values to measure the extravascular pulmonary density. With crystal probes we record pulmonary blood volume variations before, during and after exercise. Peripheral hemodynamic variations explain the change recorded at the begining and at the end of exercise. Combination of these two techniques should help us to better study the importance of the acute changes in the ''formation'' of pulmonary oedema and its influence on regional pulmonary blood volume.

  10. Non-equilibrium Inertial Separation Array for High-throughput, Large-volume Blood Fractionation.

    Science.gov (United States)

    Mutlu, Baris R; Smith, Kyle C; Edd, Jon F; Nadar, Priyanka; Dlamini, Mcolisi; Kapur, Ravi; Toner, Mehmet

    2017-08-30

    Microfluidic blood processing is used in a range of applications from cancer therapeutics to infectious disease diagnostics. As these applications are being translated to clinical use, processing larger volumes of blood in shorter timescales with high-reliability and robustness is becoming a pressing need. In this work, we report a scaled, label-free cell separation mechanism called non-equilibrium inertial separation array (NISA). The NISA mechanism consists of an array of islands that exert a passive inertial lift force on proximate cells, thus enabling gentler manipulation of the cells without the need of physical contact. As the cells follow their size-based, deterministic path to their equilibrium positions, a preset fraction of the flow is siphoned to separate the smaller cells from the main flow. The NISA device was used to fractionate 400 mL of whole blood in less than 3 hours, and produce an ultrapure buffy coat (96.6% white blood cell yield, 0.0059% red blood cell carryover) by processing whole blood at 3 mL/min, or ∼300 million cells/second. This device presents a feasible alternative for fractionating blood for transfusion, cellular therapy and blood-based diagnostics, and could significantly improve the sensitivity of rare cell isolation devices by increasing the processed whole blood volume.

  11. Determining the optimal portal blood volume in a shunt before surgery in extrahepatic portal hypertension

    Directory of Open Access Journals (Sweden)

    Yurchuk Vladimir A

    2016-04-01

    Full Text Available The aim of the study: To determine the necessary shunt diameter and assess the optimal portal blood volume in a shunt in children with extrahepatic portal hypertension before the portosystemic shunt surgery. Changes in the liver hemodynamics were studied in 81 children aged from 4 to 7 years with extrahepatic portal hypertension. We established that it is necessary to calculate the shunt diameter and the blood volume in a shunt in patients with extrahepatic portal hypertension before the portosystemic shunt surgery. It allows us to preserve the hepatic portal blood flow and effectively decrease the pressure in the portal system. Portosystemic shunt surgery in patients with extrahepatic portal hypertension performed in accordance with the individualized shunt volume significantly decreases portal pressure, preserves stable hepatic hemodynamics and prevents gastro-esophageal hemorrhage.

  12. Orthostatic changes in the blood volumes of the lower extremities in practically healthy humans

    Energy Technology Data Exchange (ETDEWEB)

    Frolov, V K; Koshkin, V M; Karalkin, A V [Vtoroj Moskovskij Gosudarstvennyj Meditsinskij Inst. (USSR)

    1979-07-01

    The method and the results of measuring the blood volumes in the lower extremities in the horizontal and vertical position of the body are given. A combination of a single-sensor counter of the whole body and a gamma-chamber with the use of two nondiffuse active radioindicators, erythrocytes labelled with /sup 51/Cr and albumin-sup(99m)Tc in certain sequence, is found to be the most optimal for quantitative evaluation of the regional volumes of the blood. To raise the informativeness of the studies the authors recommend distinguishing ''rapid'' and ''slow'' fractions of the blood volume progressive growth in the crus since the correlation of these fractions reflect the specific features of an individual orthostatic reaction for each examinee.

  13. Pulmonary blood volume and transit time in cirrhosis: relation to lung function

    DEFF Research Database (Denmark)

    Møller, Søren; Burchardt, H; Øgard, CG

    2006-01-01

    BACKGROUND/AIMS: In cirrhosis a systemic vasodilatation leads to an abnormal distribution of the blood volume with a contracted central blood volume. In addition, the patients have a ventilation/perfusion imbalance with a low diffusing capacity. As the size of the pulmonary blood volume (PBV) has...... in cirrhosis. The relation between PBV and PTT and the low diffusing capacity suggests the pulmonary vascular compartment as an important element in the pathophysiology of the lung dysfunction in cirrhosis....... not been determined separately we assessed PBV and pulmonary transit time (PTT) in relation to lung function in patients with cirrhosis and in controls. METHODS: Pulmonary and cardiac haemodynamics and transit times were determined by radionuclide techniques in 22 patients with alcoholic cirrhosis...

  14. Exercise induced pulmonary, hepatic and splenic blood volume changes in diabetic subjects

    International Nuclear Information System (INIS)

    Mubashar, M.

    1993-01-01

    Exercise induced blood volume changes in visceral organs were determined by scintillation gamma camera imaging in 11 normal healthy male volunteers and 15 NIDDM male diabetics without clinical signs of neuropathy. After in-vivo labelling of red cells with Technetium-99m, the data was acquired in the supine position at rest and immediately after graded upright ergometer bicycle exercise. From rest to peak exercise, pulmonary blood volume increased 19% and 75% in normal volunteers of less than and more than 40 years of age respectively. A decrease of 18% and 42% was noted in the hepatic and splenic blood volume respectively, regardless of the age, in the normal subjects. In contrast to normals, the diabetic patients showed in response to peak exercise as compared to age-matched controls. A significant difference in the drop in pulmonary blood volume 82.37% and 90% was observed between diabetics of more than and less than 7 years duration respectively. The liver and spleen of the diabetic subjects revealed a lesser decrease of 87.6% and 71.33% respectively in response to peak stress in comparison to the age matched controls. The reduction in the hepatic and splenic blood volume was equally evident in diabetics of more than or less than 50 years of age and it was statistically nonsignificant. This study demonstrates that the normal pattern of redistribution of blood volume in response to maximum exercise in diabetics is altered such that there is restricted pulmonary perfusion and diminished vasoconstriction of the hepato splenic vascular bed and the changes in the pulmonary circulation are related to the duration of the diabetics rather than the age of the patient. (author)

  15. Baroreflex Responses to Acute Changes in Blood Volume in Humans

    Science.gov (United States)

    Thompson, Cynthia A.; Tatro, Dana L.; Ludwig, David A.; Convertino, Victor A.

    1990-01-01

    To test the hypothesis that acute changes in plasma volume affect the stimulus-response relations of high- and low- pressure baroreflexes, eight men (27-44 yr old) underwent measurements for carotid-cardiac and cardiopulmonary baro-reflex responses under the following three volemic conditions: hypovolemic, normovolemic, and hypervolemic. The stimulus- response relation of the carotid-cardiac response curve was generated using a neck cuff device, which delivered pressure changes between +40 and -65 mmHg in continuous steps of 15 mmHg. The stimulus-response relationship, of the cardio-pulmonary baroreflex were studied by measurements of Forearm Vascular Resistance (FVR) and Peripheral Venous Pressure (PVP) during low levels of lower body negative pressure (O to -20 mmHg). The results indicate greater demand for vasoconstriction for equal reductions in venous pressure during progressive hypovolemia; this condition may compromise the capacity to provide adequate peripheral resistance during severe orthostatic stress. Fluid loading before reentry after spaceflight may act to restore vasoconstrictive capacity of the cardiopulmonary baroreflex but may not be an effective countermeasure against potential post- flight impairment of the carotid-cardiac baroreflex.

  16. Circulating atrial natriuretic peptide (ANP) and central blood volume (CBV) in cirrhosis

    DEFF Research Database (Denmark)

    Schütten, H J; Henriksen, Jens Henrik Sahl; Bendtsen, F

    1986-01-01

    Endogenous alpha-atrial natriuretic peptide (ANP) in plasma is elevated in various hypervolaemic conditions. Possible relationships between circulating immunoreactive ANP and cardiovascular and splanchnic haemodynamics were therefore studied in patients with cirrhosis (n = 16) and controls (n = 12...... or diuretic treatment. Central blood volume (CBV, i.e. the blood volume in the heart cavities, lungs, and aorta), determined from the mean transit time of 125I-labelled of 125I-labelled albumin and cardiac output, was significantly reduced in cirrhotics compared to controls (1.45 +/- 0.12 vs. 1.83 +/- 0.10 l...

  17. Blood Volume: Importance and Adaptations to Exercise Training, Environmental Stresses and Trauma Sickness

    Science.gov (United States)

    2000-02-01

    because of limb atrophy, weight loss, and inactivity) because erythro- cyte levels of 2,3- diphosphoglycerate (2,3-DPG) were in- creased. However...blood volume expansion during exercise training may partially be explained by factors such as initial fitness level , training intensity, exercise mode...335 and their hydration level when measurements are made (131). Plasma volume expansion seems to be greatest when performing upright exercise on about

  18. Blood volume determination with two radioisotopes: application to non-cardiogenic shock

    International Nuclear Information System (INIS)

    Mallet, J.-J.

    1975-01-01

    Knowledge of the circulating blood volume may be of great assistance in the study of clinical shock. The isotope dilution principle is used to measure both plasma and red cell volume. Considering the increased capillary permeability in patients in shock, it may be of considerable value to quantify the diffusion of liquid through the capillary walls. A double determination of the volume of distribution of the tracer is to be envisaged. Two methods are described. The first one uses a non-diffusible tracer (sup(99m)Tc-labelled red cells) confined to the intravascular space, giving a measure of the intravascular blood volume. The latter uses 131 I-labelled serum albumin which remains, usually, in the vascular bed, but is able to diffuse through the pores of the capillary membrane, because of its low molecular weight. A resulting increase of the tracer volume distribution, with regard to this capillary diffusion is considered. A comparison of the two methods used simultaneously appear to provide information on the possible liquid diffusion in clinical shock. The results obtained in several pathological conditions are described. They enable conclusion to be drawn on the possibility of errors introduced by the use of 131 I-labelled serum albumin alone in determining the circulating blood volume in clinical shock [fr

  19. Chronic fatigue syndrome: illness severity, sedentary lifestyle, blood volume and evidence of diminished cardiac function.

    Science.gov (United States)

    Hurwitz, Barry E; Coryell, Virginia T; Parker, Meela; Martin, Pedro; Laperriere, Arthur; Klimas, Nancy G; Sfakianakis, George N; Bilsker, Martin S

    2009-10-19

    The study examined whether deficits in cardiac output and blood volume in a CFS (chronic fatigue syndrome) cohort were present and linked to illness severity and sedentary lifestyle. Follow-up analyses assessed whether differences in cardiac output levels between CFS and control groups were corrected by controlling for cardiac contractility and TBV (total blood volume). The 146 participants were subdivided into two CFS groups based on symptom severity data, severe (n=30) and non-severe (n=26), and two healthy non-CFS control groups based on physical activity, sedentary (n=58) and non-sedentary (n=32). Controls were matched to CFS participants using age, gender, ethnicity and body mass. Echocardiographic measures indicated that the severe CFS participants had 10.2% lower cardiac volume (i.e. stroke index and end-diastolic volume) and 25.1% lower contractility (velocity of circumferential shortening corrected by heart rate) than the control groups. Dual tag blood volume assessments indicated that the CFS groups had lower TBV, PV (plasma volume) and RBCV (red blood cell volume) than control groups. Of the CFS subjects with a TBV deficit (i.e. > or = 8% below ideal levels), the mean+/-S.D. percentage deficit in TBV, PV and RBCV were -15.4+/-4.0, -13.2+/-5.0 and -19.1+/-6.3% respectively. Lower cardiac volume levels in CFS were substantially corrected by controlling for prevailing TBV deficits, but were not affected by controlling for cardiac contractility levels. Analyses indicated that the TBV deficit explained 91-94% of the group differences in cardiac volume indices. Group differences in cardiac structure were offsetting and, hence, no differences emerged for left ventricular mass index. Therefore the findings indicate that lower cardiac volume levels, displayed primarily by subjects with severe CFS, were not linked to diminished cardiac contractility levels, but were probably a consequence of a co-morbid hypovolaemic condition. Further study is needed to address

  20. Evaluation of the effects of insufficient blood volume samples on the performance of blood glucose self-test meters.

    Science.gov (United States)

    Pfützner, Andreas; Schipper, Christina; Ramljak, Sanja; Flacke, Frank; Sieber, Jochen; Forst, Thomas; Musholt, Petra B

    2013-11-01

    Accuracy of blood glucose readings is (among other things) dependent on the test strip being completely filled with sufficient sample volume. The devices are supposed to display an error message in case of incomplete filling. This laboratory study was performed to test the performance of 31 commercially available devices in case of incomplete strip filling. Samples with two different glucose levels (60-90 and 300-350 mg/dl) were used to generate three different sample volumes: 0.20 µl (too low volume for any device), 0.32 µl (borderline volume), and 1.20 µl (low but supposedly sufficient volume for all devices). After a point-of-care capillary reference measurement (StatStrip, NovaBiomedical), the meter strip was filled (6x) with the respective volume, and the response of the meters (two devices) was documented (72 determinations/meter type). Correct response was defined as either an error message indicating incomplete filling or a correct reading (±20% compared with reference reading). Only five meters showed 100% correct responses [BGStar and iBGStar (both Sanofi), ACCU-CHEK Compact+ and ACCU-CHEK Mobile (both Roche Diagnostics), OneTouch Verio (LifeScan)]. The majority of the meters (17) had up to 10% incorrect reactions [predominantly incorrect readings with sufficient volume; Precision Xceed and Xtra, FreeStyle Lite, and Freedom Lite (all Abbott); GlucoCard+ and GlucoMen GM (both Menarini); Contour, Contour USB, and Breeze2 (all Bayer); OneTouch Ultra Easy, Ultra 2, and Ultra Smart (all LifeScan); Wellion Dialog and Premium (both MedTrust); FineTouch (Terumo); ACCU-CHEK Aviva (Roche); and GlucoTalk (Axis-Shield)]. Ten percent to 20% incorrect reactions were seen with OneTouch Vita (LifeScan), ACCU-CHEK Aviva Nano (Roche), OmniTest+ (BBraun), and AlphaChek+ (Berger Med). More than 20% incorrect reactions were obtained with Pura (Ypsomed), GlucoCard Meter and GlucoMen LX (both Menarini), Elite (Bayer), and MediTouch (Medisana). In summary, partial and

  1. Effects of Anti-VEGF on Predicted Antibody Biodistribution: Roles of Vascular Volume, Interstitial Volume, and Blood Flow

    Science.gov (United States)

    Boswell, C. Andrew; Ferl, Gregory Z.; Mundo, Eduardo E.; Bumbaca, Daniela; Schweiger, Michelle G.; Theil, Frank-Peter; Fielder, Paul J.; Khawli, Leslie A.

    2011-01-01

    Background The identification of clinically meaningful and predictive models of disposition kinetics for cancer therapeutics is an ongoing pursuit in drug development. In particular, the growing interest in preclinical evaluation of anti-angiogenic agents alone or in combination with other drugs requires a complete understanding of the associated physiological consequences. Methodology/Principal Findings Technescan™ PYP™, a clinically utilized radiopharmaceutical, was used to measure tissue vascular volumes in beige nude mice that were naïve or administered a single intravenous bolus dose of a murine anti-vascular endothelial growth factor (anti-VEGF) antibody (10 mg/kg) 24 h prior to assay. Anti-VEGF had no significant effect (p>0.05) on the fractional vascular volumes of any tissues studied; these findings were further supported by single photon emission computed tomographic imaging. In addition, apart from a borderline significant increase (p = 0.048) in mean hepatic blood flow, no significant anti-VEGF-induced differences were observed (p>0.05) in two additional physiological parameters, interstitial fluid volume and the organ blood flow rate, measured using indium-111-pentetate and rubidium-86 chloride, respectively. Areas under the concentration-time curves generated by a physiologically-based pharmacokinetic model changed substantially (>25%) in several tissues when model parameters describing compartmental volumes and blood flow rates were switched from literature to our experimentally derived values. However, negligible changes in predicted tissue exposure were observed when comparing simulations based on parameters measured in naïve versus anti-VEGF-administered mice. Conclusions/Significance These observations may foster an enhanced understanding of anti-VEGF effects in murine tissues and, in particular, may be useful in modeling antibody uptake alone or in combination with anti-VEGF. PMID:21436893

  2. Altitude acclimatization and blood volume: effects of exogenous erythrocyte volume expansion

    DEFF Research Database (Denmark)

    Sawka, M N; Young, Jette Feveile; Rock, P B

    1996-01-01

    blood oxygen content alters erythropoietin responses during altitude acclimatization, and 4) mechanisms responsible for plasma loss at altitude. Sixteen healthy men had a series of hematologic measurements made at sea level, on the first and ninth days of altitude (4,300 m) residence, and after...

  3. White cell labeling: 20 ML VS 4 ML of blood volume-case reports

    International Nuclear Information System (INIS)

    Imam, S.K.

    1998-01-01

    Full text: Some times, it becomes difficult to draw 20 mL blood from a patient with bad veins. On two occasions, we could collect only about 4 mL of blood, that too with a great deal of struggle, and then we carried out the routine labelling procedure. A labelling efficiency of 98.2% and 95.6% was achieved. The white cell scan was negative in one patient, but positive in the next one. In a third patient, a comparison of labelling efficiency was done between 5 and 20 mLs of blood volumes separately and the results were found to be identical, 98.5% and 98.4%, respectively. As we have achieved the usual pattern of white cell scan with as low as 4-5 mL of blood, it appears that enough number of white cells is present even in the 4-5 mL of blood that is capable of generating a white cell scan and so, it seems rational to reduce the blood volume from 20 mL to 4 or 5 mL. However, further studies are warranted before adopting this modification. The procedure appears to carry the following advantages: ease of blood collection, handling and re-injection and less risk to the patient

  4. Susceptibility contrast imaging of CO2-induced changes in the blood volume of the human brain

    DEFF Research Database (Denmark)

    Rostrup, Egill; Larsson, H B; Toft, P B

    1996-01-01

    PURPOSE: To investigate changes in the regional cerebral blood volume (rCBV) in human subjects during rest and hypercapnia by MR imaging, and to compare the results from contrast-enhanced and noncontrast-enhanced susceptibility-weighted imaging. MATERIAL AND METHODS: Five healthy volunteers (aged...

  5. Blood flow and blood volume in the femoral heads of healthy adults according to age. Measurement with positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Kubo, Toshikazu; Kimori, Kokuto; Nakamura, Fuminori; Inoue, Shigehiro; Fujioka, Mikihiro; Ueshima, Keiichiro; Hirasawa, Yasusuke; Ushijima, Yo; Nishimura, Tsunehiko

    2001-01-01

    To deepen understanding of hemodynamics in the femoral head, i.e., the essential factor in clarifying pathogenesis of hip disorders, this study examined blood flow and blood volume in the femoral heads of healthy adults, and their changes with age, by using positron emission tomography (PET). In 16 healthy adult males (age: 20-78 years old, mean age: 42 years), blood flow was measured by means of the H 2 15 O dynamic study method, and blood volume was measured by means of the 15 O-labeled carbon monoxide bolus inhalation method. Blood flow was 1.68-6.47 ml/min/100 g (mean ±SD: 3.52±1.2), and blood volume was 1.67-6.03 ml/100 g (mean ±SD: 3.00±1.27). Blood flow significantly decreased (p<0.01) with age, and blood volume significantly increased (P<0.05). PET was useful in the measurement of blood flow and blood volume in the femoral heads. With age, physiological hemodynamic changes also increased in femoral heads. (author)

  6. Evaluation of the BD BACTEC FX blood volume monitoring system as a continuous quality improvement measure.

    Science.gov (United States)

    Coorevits, L; Van den Abeele, A-M

    2015-07-01

    The yield of blood cultures is proportional to the volume of blood cultured. We evaluated an automatic blood volume monitoring system, recently developed by Becton Dickinson within its BACTEC EpiCenter module, that calculates mean volumes of negative aerobic bottles and generates boxplots and histograms. First, we evaluated the filling degree of 339 aerobic glass blood cultures by calculating the weight-based volume for each bottle. A substantial amount of the bottles (48.3%) were inadequately filled. Evaluation of the accuracy of the monitoring system showed a mean bias of -1.4 mL (-15.4%). Additional evaluation, using the amended software on 287 aerobic blood culture bottles, resulted in an acceptable mean deviation of -0.3 mL (-3.3%). The new software version was also tested on 200 of the recently introduced plastic bottles, which will replace the glass bottles in the near future, showing a mean deviation of +2.8 mL (+26.7%). In conclusion, the mean calculated volumes can be used for the training of a single phlebotomist. However, filling problems appear to be masked when using them for phlebotomist groups or on wards. Here, visual interpretation of boxplots and histograms can serve as a useful tool to observe the spread of the filling degrees and to develop a continuous improvement program. Re-adjustment of the software has proven to be necessary for use with plastic bottles. Due to our findings, BD has developed further adjustments to the software for validated use with plastic bottles, which will be released soon.

  7. Effect of volume loading on the Frank-Starling relation during reductions in central blood volume in heat-stressed humans

    DEFF Research Database (Denmark)

    Bundgaard-Nielsen, Morten; Wilson, T E; Seifert, Thomas

    2010-01-01

    During reductions in central blood volume while heat stressed, a greater decrease in stroke volume (SV) for a similar decrease in ventricular filling pressure, compared to normothermia, suggests that the heart is operating on a steeper portion of a Frank-Starling curve. If so, volume loading...... of heat-stressed individuals would shift the operating point to a flatter portion of the heat stress Frank-Starling curve thereby attenuating the reduction in SV during subsequent decreases in central blood volume. To investigate this hypothesis, right heart catheterization was performed in eight males...... from whom pulmonary capillary wedge pressure (PCWP), central venous pressure and SV (via thermodilution) were obtained while central blood volume was reduced via lower-body negative pressure (LBNP) during normothermia, whole-body heating (increase in blood temperature 1 degrees C), and during whole...

  8. Blood Volume, Plasma Volume and Circulation Time in a High-Energy-Demand Teleost, the Yellowfin Tuna (Thunnus Albacares)

    DEFF Research Database (Denmark)

    Brill, R.W.; Cousins, K.L.; Jones, D.R.

    1998-01-01

    We measured red cell space with 51Cr-labeled red blood cells, and dextran space with 500 kDa fluorescein-isothiocyanate-labeled dextran (FITC-dextran), in two groups of yellowfin tuna (Thunnus albacares). Red cell space was 13.8+/-0.7 ml kg-1 (mean +/- s.e.m.) Assuming a whole- body hematocrit...... for albacore (Thunnus alalunga, 82-197 ml kg-1). Plasma volume within the primary circulatory system (calculated from the 51Cr-labeled red blood cell data) was 32.9+/-2.3 ml kg-1. Dextran space was 37.0+/-3.7 ml kg-1. Because 500 kDa FITC-dextran appeared to remain within the vascular space, these data imply...

  9. Changes in extracellular muscle volume affect heart rate and blood pressure responses to static exercise

    Science.gov (United States)

    Baum, K.; Essfeld, D.; Stegemann, J.

    To investigate the effect of μg-induced peripheral extracellular fluid reductions on heart rate and blood pressure during isometric exercise, six healthy male subjects performed three calf ergometer test with different extracellular volumes of working muscles. In all tests, body positions during exercise were identical (supine with the knee joint flexed to 900). After a pre-exercise period of 25 min, during which calf volumes were manipulated, subjects had to counteract an external force of 180 N for 5 min. During the pre-exercise period three different protocols were applied. Test A: Subjects rested in the exercise position; test B: Body position was the same as in A but calf volume was increased by venous congestion (cuffs inflated to 80 mm Hg); test C: Calf volumes were decreased by a negative hydrostatic pressure (calves about 40 cm above heart level with the subjects supine). To clamp the changed calf volumes in tests B and C, cuffs were inflated to 300 mm Hg 5 min before the onset of exercise. This occlusion was maintained until termination of exercise. Compared to tests A and B, the reduced volume of test C led to significant increases in heart rate and blood pressure during exercise. Oxygen uptake did not exceed resting levels in B and C until cuffs were deflated, indicating that exclusively calf muscles contributed to the neurogenic peripheral drive. It is concluded that changes in extracellular muscle volume have to be taken into account when comparing heart rate and blood pressure during lg- and μg- exercise.

  10. Sequential assessment of regional cerebral blood flow, regional cerebral blood volume, and blood-brain barrier in focal cerebral ischemia: a case report

    International Nuclear Information System (INIS)

    Di Piero, V.; Perani, D.; Savi, A.; Gerundini, P.; Lenzi, G.L.; Fazio, F.

    1986-01-01

    Regional CBF (rCBF) and regional cerebral blood volume (rCBV) were evaluated by N,N,N'-trimethyl-N'-(2)-hydroxy-3-methyl-5-[123I]iodobenzyl-1, 3-propanediamine-2 HCl- and /sup 99m/TC-labeled red blood cells, respectively, and single-photon emission computerized tomography (SPECT) in a patient with focal cerebral ischemia. Sequential transmission computerized tomography (TCT) and SPECT functional data were compared with clinical findings to monitor the pathophysiological events occurring in stroke. A lack of correlation between rCBF-rCBV distributions and blood-brain barrier (BBB) breakdown was found in the acute phase. In the face of more prolonged alteration of BBB, as seen by TCT enhancement, a rapid evolution of transient phenomena such as luxury perfusion was shown by SPECT studies. Follow-up of the patient demonstrated a correlation between the neurological recovery and a parallel relative improvement of the cerebral perfusion

  11. Errors of the backextrapolation method in determination of the blood volume

    Science.gov (United States)

    Schröder, T.; Rösler, U.; Frerichs, I.; Hahn, G.; Ennker, J.; Hellige, G.

    1999-01-01

    Backextrapolation is an empirical method to calculate the central volume of distribution (for example the blood volume). It is based on the compartment model, which says that after an injection the substance is distributed instantaneously in the central volume with no time delay. The occurrence of recirculation is not taken into account. The change of concentration with time of indocyanine green (ICG) was observed in an in vitro model, in which the volume was recirculating in 60 s and the clearance of the ICG could be varied. It was found that the higher the elimination of ICG, the higher was the error of the backextrapolation method. The theoretical consideration of Schröder et al ( Biomed. Tech. 42 (1997) 7-11) was proved. If the injected substance is eliminated somewhere in the body (i.e. not by radioactive decay), the backextrapolation method produces large errors.

  12. Variations in gastric compliance induced by acute blood volume changes in anesthetized rats

    Directory of Open Access Journals (Sweden)

    Graça J.R.V.

    2002-01-01

    Full Text Available The impact of acute volume imbalances on gastric volume (GV was studied in anesthetized rats (250-300 g. After cervical and femoral vessel cannulation, a balloon catheter was positioned in the proximal stomach. The opposite end of the catheter was connected to a barostat with an electronic sensor coupled to a plethysmometer. A standard ionic solution was used to fill the balloon (about 3.0 ml and the communicating vessel system, and to raise the reservoir liquid level 4 cm above the animals' xiphoid appendix. Due to constant barostat pressure, GV values were considered to represent the gastric compliance index. All animals were monitored for 90 min. After a basal interval, they were randomly assigned to normovolemic, hypervolemic, hypovolemic or restored protocols. Data were compared by ANOVA followed by Bonferroni's test. Mean arterial pressure (MAP, central venous pressure (CVP and GV values did not change in normovolemic animals (N = 5. Hypervolemic animals (N = 12 were transfused at 0.5 ml/min with a suspension of red blood cells in Ringer-lactate solution with albumin (12.5 ml/kg, which reduced GV values by 11.3% (P0.05. MAP and CVP values increased (P<0.05 after hypervolemia but decreased (P<0.05 with hypovolemia. In conclusion, blood volume level modulates gastric compliance, turning the stomach into an adjustable reservoir, which could be part of the homeostatic process to balance blood volume.

  13. The effect of intralesional steroid injections on the volume and blood flow in periocular capillary haemangiomas.

    Science.gov (United States)

    Verity, David H; Rose, Geoffrey E; Restori, M

    2008-01-01

    To examine the effect of steroid therapy on the volume estimates and blood flow characteristics of childhood periorbital capillary haemangiomas. Children at risk of amblyopia due to periorbital haemangiomas were treated with intralesional steroid injections (between 1 and 4 courses) and serial assessment of the volume and blood-flow characteristics of the lesions measured using colour Doppler ultrasonography. The characteristics of the haemangiomas in these children were compared with a cohort of untreated cases. Eight of nine treated children were female, this proportion being significantly different from the equal sex distribution of an untreated cohort (p suppression persisting for several months (between 5 and 20) before the lesion later displays the cyclic fluctuations in volume and flow seen with untreated lesions. All treated haemangiomas had some residual vascular anomaly, detectable on ultrasonography, at last follow-up--this being despite absence of clinical signs in most cases. Periorbital capillary haemangiomas requiring steroid therapy for risk of amblyopia were significantly commoner in females, were larger lesions and presented at an earlier age. Intralesional steroids appear to cause a reduction of blood flow, with a transient reduction in volume and a suppression of the natural cyclic variation seen without treatment. The changes after a course of steroid therapy appear to last for between 5 and 20 months, this period of suppression of the lesion probably being particularly useful during infancy and early childhood when the child is at greatest risk of amblyopia.

  14. Human cerebral blood volume measurements using dynamic contrast enhancement in comparison to dynamic susceptibility contrast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Artzi, Moran [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Sackler Faculty of Medicine, Tel Aviv (Israel); Liberman, Gilad; Vitinshtein, Faina; Aizenstein, Orna [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Nadav, Guy [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Faculty of Engineering, Tel Aviv (Israel); Blumenthal, Deborah T.; Bokstein, Felix [Tel Aviv Sourasky Medical Center, Neuro-Oncology Service, Tel Aviv (Israel); Bashat, Dafna Ben [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Sackler Faculty of Medicine and Sagol School of Neuroscience, Tel Aviv (Israel)

    2015-07-15

    Cerebral blood volume (CBV) is an important parameter for the assessment of brain tumors, usually obtained using dynamic susceptibility contrast (DSC) MRI. However, this method often suffers from low spatial resolution and high sensitivity to susceptibility artifacts and usually does not take into account the effect of tissue permeability. The plasma volume (v{sub p}) can also be extracted from dynamic contrast enhancement (DCE) MRI. The aim of this study was to investigate whether DCE can be used for the measurement of cerebral blood volume in place of DSC for the assessment of patients with brain tumors. Twenty-eight subjects (17 healthy subjects and 11 patients with glioblastoma) were scanned using DCE and DSC. v{sub p} and CBV values were measured and compared in different brain components in healthy subjects and in the tumor area in patients. Significant high correlations were detected between v{sub p} and CBV in healthy subjects in the different brain components; white matter, gray matter, and arteries, correlating with the known increased tissue vascularity, and within the tumor area in patients. This work proposes the use of DCE as an alternative method to DSC for the assessment of blood volume, given the advantages of its higher spatial resolution, its lower sensitivity to susceptibility artifacts, and its ability to provide additional information regarding tissue permeability. (orig.)

  15. Portal blood flow volume measurement in schistosomal patients: evaluation of Doppler ultrasonography reproducibility

    International Nuclear Information System (INIS)

    Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; Shigueoka, David Carlos; D'Ippolito, Giuseppe; Colleoni, Ramiro

    2008-01-01

    Objective: To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. Materials and methods: Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient. Results: Interobserver agreement was excellent. Intraclass correlation ranged from 80.6% to 93.0% (IC at 95% [65.3% ; 95.8%]), with the Pearson's correlation coefficient ranging between 81.6% and 92.7% with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749). Conclusion: Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement. (author)

  16. Determination of the cerebral blood volume by computer tomography in grey and white matter

    International Nuclear Information System (INIS)

    Ladurner, G.

    1978-01-01

    Until now cerebral blood volume estimations have been made using dye dilution methods, by labelling the red cells with Cr 51 , Tc 99 , or I 131 , or using radiofluorescence or from regional cerebral blood flow. A new method of measurement of rCBV will be described which employs contrast medium and computer tomography. A scan before the intravenous introduction of contrast medium is subtracted from the scan following, using a second computer. At the same time during the scans measurements are made of the contrast medium level in the blood, the haematocrit and the capillary PCO 2 tension. From the subtraction picture which represents the density change in the vascular compartment due to the contrast medium, and knowing the plasma contrast medium level, the regional plasma volume can be calculated. Hence, taking the haematorcrit into account, the regional blood volume can be estimated. The greatest advantage of the subtraction method of measuring rCBV is that it is non-invasive. Also the three dimensional information is better and the definition more exact than in other methods making possible estimations of rCBV in definite anatomical areas so that for the first time CBV can be assessed in the basal ganglion. In addition changes in rCBV with hyperventilation can be measured. (orig./VJ) [de

  17. Portal blood flow volume measurement in schistosomal patients: evaluation of Doppler ultrasonography reproducibility

    Energy Technology Data Exchange (ETDEWEB)

    Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; Shigueoka, David Carlos; D' Ippolito, Giuseppe [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostico por Imagem]. E-mail: ar.leao@uol.com.br; Colleoni, Ramiro [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Gastroenterologia

    2008-09-15

    Objective: To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. Materials and methods: Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient. Results: Interobserver agreement was excellent. Intraclass correlation ranged from 80.6% to 93.0% (IC at 95% [65.3% ; 95.8%]), with the Pearson's correlation coefficient ranging between 81.6% and 92.7% with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749). Conclusion: Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement. (author)

  18. Revisiting the Logan plot to account for non-negligible blood volume in brain tissue.

    Science.gov (United States)

    Schain, Martin; Fazio, Patrik; Mrzljak, Ladislav; Amini, Nahid; Al-Tawil, Nabil; Fitzer-Attas, Cheryl; Bronzova, Juliana; Landwehrmeyer, Bernhard; Sampaio, Christina; Halldin, Christer; Varrone, Andrea

    2017-08-18

    Reference tissue-based quantification of brain PET data does not typically include correction for signal originating from blood vessels, which is known to result in biased outcome measures. The bias extent depends on the amount of radioactivity in the blood vessels. In this study, we seek to revisit the well-established Logan plot and derive alternative formulations that provide estimation of distribution volume ratios (DVRs) that are corrected for the signal originating from the vasculature. New expressions for the Logan plot based on arterial input function and reference tissue were derived, which included explicit terms for whole blood radioactivity. The new methods were evaluated using PET data acquired using [ 11 C]raclopride and [ 18 F]MNI-659. The two-tissue compartment model (2TCM), with which signal originating from blood can be explicitly modeled, was used as a gold standard. DVR values obtained for [ 11 C]raclopride using the either blood-based or reference tissue-based Logan plot were systematically underestimated compared to 2TCM, and for [ 18 F]MNI-659, a proportionality bias was observed, i.e., the bias varied across regions. The biases disappeared when optimal blood-signal correction was used for respective tracer, although for the case of [ 18 F]MNI-659 a small but systematic overestimation of DVR was still observed. The new method appears to remove the bias introduced due to absence of correction for blood volume in regular graphical analysis and can be considered in clinical studies. Further studies are however required to derive a generic mapping between plasma and whole-blood radioactivity levels.

  19. Doppler sonography of diabetic feet: Quantitative analysis of blood flow volume

    International Nuclear Information System (INIS)

    Seo, Young Lan; Kim, Ho Chul; Choi, Chul Soon; Yoon, Dae Young; Han, Dae Hee; Moon, Jeung Hee; Bae, Sang Hoon

    2002-01-01

    To analyze Doppler sonographic findings of diabetic feet by estimating the quantitative blood flow volume and by analyzing waveform on Doppler. Doppler sonography was performed in thirty four patients (10 diabetic patients with foot ulceration, 14 diabetic patients without ulceration and 10 normal patients as the normal control group) to measure the flow volume of the arteries of the lower extremities (posterior and anterior tibial arteries, and distal femoral artery. Analysis of doppler waveforms was also done to evaluate the nature of the changed blood flow volume of diabetic patients, and the waveforms were classified into triphasic, biphasic-1, biphasic-2 and monophasic patterns. Flow volume of arteries in diabetic patients with foot ulceration was increased witha statistical significance when compared to that of diabetes patients without foot ulceration of that of normal control group (P<0.05). Analysis of Doppler waveform revealed that the frequency of biphasic-2 pattern was significantly higher in diabetic patients than in normal control group(p<0.05). Doppler sonography in diabetic feet showed increased flow volume and biphasic Doppler waveform, and these findings suggest neuropathy rather than ischemic changes in diabetic feet.

  20. Doppler sonography of diabetic feet: Quantitative analysis of blood flow volume

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Young Lan; Kim, Ho Chul; Choi, Chul Soon; Yoon, Dae Young; Han, Dae Hee; Moon, Jeung Hee; Bae, Sang Hoon [Hallym University College of Medicine, Seoul (Korea, Republic of)

    2002-09-15

    To analyze Doppler sonographic findings of diabetic feet by estimating the quantitative blood flow volume and by analyzing waveform on Doppler. Doppler sonography was performed in thirty four patients (10 diabetic patients with foot ulceration, 14 diabetic patients without ulceration and 10 normal patients as the normal control group) to measure the flow volume of the arteries of the lower extremities (posterior and anterior tibial arteries, and distal femoral artery. Analysis of doppler waveforms was also done to evaluate the nature of the changed blood flow volume of diabetic patients, and the waveforms were classified into triphasic, biphasic-1, biphasic-2 and monophasic patterns. Flow volume of arteries in diabetic patients with foot ulceration was increased witha statistical significance when compared to that of diabetes patients without foot ulceration of that of normal control group (P<0.05). Analysis of Doppler waveform revealed that the frequency of biphasic-2 pattern was significantly higher in diabetic patients than in normal control group(p<0.05). Doppler sonography in diabetic feet showed increased flow volume and biphasic Doppler waveform, and these findings suggest neuropathy rather than ischemic changes in diabetic feet.

  1. Noninvasive MRI measurement of the absolute cerebral blood volume-cerebral blood flow relationship during visual stimulation in healthy humans.

    Science.gov (United States)

    Ciris, Pelin Aksit; Qiu, Maolin; Constable, R Todd

    2014-09-01

    The relationship between cerebral blood volume (CBV) and cerebral blood flow (CBF) underlies blood oxygenation level-dependent functional MRI signal. This study investigates the potential for improved characterization of the CBV-CBF relationship in humans, and examines sex effects as well as spatial variations in the CBV-CBF relationship. Healthy subjects were imaged noninvasively at rest and during visual stimulation, constituting the first MRI measurement of the absolute CBV-CBF relationship in humans with complete coverage of the functional areas of interest. CBV and CBF estimates were consistent with the literature, and their relationship varied both spatially and with sex. In a region of interest with stimulus-induced activation in CBV and CBF at a significance level of the P < 0.05, a power function fit resulted in CBV = 2.1 CBF(0.32) across all subjects, CBV = 0.8 CBF(0.51) in females and CBV = 4.4 CBF(0.15) in males. Exponents decreased in both sexes as ROIs were expanded to include less significantly activated regions. Consideration for potential sex-related differences, as well as regional variations under a range of physiological states, may reconcile some of the variation across literature and advance our understanding of the underlying cerebrovascular physiology. Copyright © 2013 Wiley Periodicals, Inc.

  2. Cerebral blood volume changes in cats with acute increased intracranial pressure

    International Nuclear Information System (INIS)

    Kondo, Takashi; Kano, Mitsumasa; Ikeda, Takuya.

    1984-01-01

    We measured the changes in cerebral blood volume in cats with increased intracranial pressure with a high-speed CT scanner, employing contrast effects by the iodine agent. In acute increased intracranial pressure caused by raising the extradural pressure by 20 mmHg, cerebral blood volume showed a significant decrease by 32% in comparison with that at normal intracranial pressure. There was also a tendency that a decline of iodine was delayed with time at increased intracranial pressure than that at normal pressure. This was supposed to be a delay of cerebral circulation due to venous congestion. This experimental model and measuring method provide the changes in CBV in the same individual without any tedious procedure, and therefore this is a reliable method with respect to precision. (author)

  3. The Blood Volume of the Guinea Pig: Effects of Epinephrine and Isoproterenol upon the Red Cell and Plasma Volumes, Heart Rate, and Mean Arterial Pressure,

    Science.gov (United States)

    1987-09-01

    capillaries (4), blood volumes calculated from plasma volume measures must correct for label that has left the system between the time of the injected dose...Splenic sequestration and contraction are mediated by the autonomic nervous system and blood-borne agents (10). Sympathetic nerve fibers from the truncus...sympathlcus and parasympathetic neurons of the nervus vagus (cranial nerve X) innervate the celiac plexus (8, 11). A subdivision of the celiac plexus

  4. Detection of Low-volume Blood Loss: Compensatory Reserve Versus Traditional Vital Signs

    Science.gov (United States)

    2014-01-01

    follows: heart rate (HR), blood pressure (BP), respiratory rate, and oxygen saturation. These vital signs are, however, notoriously unreliable.2,3 As...additional tests using specific equipment.22 Base deficit (BD) is a rapidly and widely available serum laboratory marker of systemic acidosis that...and mortality.23,24 BD can increase, however, because of any derangement causing metabolic acidosis and is not limited to intravascular volume loss

  5. Susceptibility contrast imaging of CO2-induced changes in the blood volume of the human brain

    DEFF Research Database (Denmark)

    Rostrup, Egill; Larsson, H B; Toft, P B

    1996-01-01

    PURPOSE: To investigate changes in the regional cerebral blood volume (rCBV) in human subjects during rest and hypercapnia by MR imaging, and to compare the results from contrast-enhanced and noncontrast-enhanced susceptibility-weighted imaging. MATERIAL AND METHODS: Five healthy volunteers (aged...... in cerebral hemodynamics than noncontrast-enhanced imaging. The results of the deconvolution analysis suggested that perfusion calculation by conventional tracer kinetic methods may be impracticable because of nonlinear effects in contrast-enhanced MR imaging....

  6. Pulmonary diffusing capacity, capillary blood volume, and cardiac output during sustained microgravity

    Science.gov (United States)

    Prisk, G. K.; Guy, Harold J. B.; Elliott, Ann R.; Deutschman, Robert A., III; West, John B.

    1993-01-01

    We measured pulmonary diffusing capacity (DL), diffusing capacity per unit lung volume, pulmonary capillary blood volume (Vc), membrane diffusing capacity (Dm), pulmonary capillary blood flow or cardiac output (Qc), and cardiac stroke volume (SV) in four subjects exposed to nine days of microgravity. DL in microgravity was elevated compared with preflight standing values and was higher than preflight supine because of the elevation of both Vc and Dm. The elevation in Vc was comparable to that measured supine in 1 G, but the increase in Dm was in sharp contrast to the supine value. We postulate that, in 0 G, pulmonary capillary blood is evenly distributed throughout the lung, providing for uniform capillary filling, leading to an increase in the surface area available for diffusion. By contrast, in the supine 1-G state, the capillaries are less evenly filled, and although a similar increase in blood volume is observed, the corresponding increase in surface area does not occur. DL and its subdivisions showed no adaptive changes from the first measurement 24 h after the start of 0 G to eight days later. Similarly, there were no trends in the postflight data, suggesting that the principal mechanism of these changes was gravitational. The increase in Dm suggests that subclinical pulmonary edema did not result from exposure to 0 G. Qc was modestly increased inflight and decreased postflight compared with preflight standing. Compared with preflight standing, SV was increased 46 percent inflight and decreased 14 percent in the 1st week postflight. There were temporal changes in Qc and SV during 0 G, with the highest values recorded at the first measurement, 24 h into the flight. The lowest values of Qc and SV occurred on the day of return.

  7. Precision of a new bedside method for estimation of the circulating blood volume

    DEFF Research Database (Denmark)

    Christensen, P; Eriksen, B; Henneberg, S W

    1993-01-01

    The present study is a theoretical and experimental evaluation of a modification of the carbon monoxide method for estimation of the circulating blood volume (CBV) with respect to the precision of the method. The CBV was determined from measurements of the CO-saturation of hemoglobin before and a......, determination of CBV can be performed with an amount of CO that gives rise to a harmless increase in the carboxyhemoglobin concentration.(ABSTRACT TRUNCATED AT 250 WORDS)...

  8. Noninvasive measurement of cardiopulmonary blood volume: evaluation of the centroid method

    International Nuclear Information System (INIS)

    Fouad, F.M.; MacIntyre, W.J.; Tarazi, R.C.

    1981-01-01

    Cardiopulmonary blood volume (CPV) and mean pulmonary transit time (MTT) determined by radionuclide measurements (Tc-99m HSA) were compared with values obtained from simultaneous dye-dilution (DD) studies (indocyanine green). The mean transit time was obtained from radionuclide curves by two methods: the peak-to-peak time and the interval between the two centroids determined from the right and left-ventricular time-concentration curves. Correlation of dye-dilution MTT and peak-to-peak time was significant (r = 0.79, p < 0.001), but its correlation with centroid-derived values was better (r = 0.86, p < 0.001). CPV values (using the centroid method for radionuclide technique) correlated significantly with values derived from dye-dilution curves (r = 0.74, p < 0.001). Discrepancies between the two were greater the more rapid the circulation (r = 0.61, p < 0.01), suggesting that minor inaccuracies of dye-dilution methods, due to positioning or delay of the system, can become magnified in hyperkinetic conditions. The radionuclide method is simple, repeatable, and noninvasive, and it provides simultaneous evaluation of pulmonary and systemic hemodynamics. Further, calculation of the ratio of cardiopulmonary to total blood volume can be used as an index of overall venous distensibility and relocation of intravascular blood volume

  9. Volume-activated trimethylamine oxide efflux in red blood cells of spiny dogfish (Squalus acanthias).

    Science.gov (United States)

    Koomoa, D L; Musch, M W; MacLean, A V; Goldstein, L

    2001-09-01

    The aims of this study were to determine the pathway of swelling-activated trimethylamine oxide (TMAO) efflux and its regulation in spiny dogfish (Squalus acanthias) red blood cells and compare the characteristics of this efflux pathway with the volume-activated osmolyte (taurine) channel present in erythrocytes of fishes. The characteristics of the TMAO efflux pathway were similar to those of the taurine efflux pathway. The swelling-activated effluxes of both TMAO and taurine were significantly inhibited by known anion transport inhibitors (DIDS and niflumic acid) and by the general channel inhibitor quinine. Volume expansion by hypotonicity, ethylene glycol, and diethyl urea activated both TMAO and taurine effluxes similarly. Volume expansion by hypotonicity, ethylene glycol, and diethyl urea also stimulated the activity of tyrosine kinases p72syk and p56lyn, although the stimulations by the latter two treatments were less than by hypotonicity. The volume activations of both TMAO and taurine effluxes were inhibited by tyrosine kinase inhibitors, suggesting that activation of tyrosine kinases may play a role in activating the osmolyte effluxes. These results indicate that the volume-activated TMAO efflux occurs via the organic osmolyte (taurine) channel and may be regulated by the volume activation of tyrosine kinases.

  10. Relationship between Stroke Volume Variation and Blood Transfusion during Liver Transplantation.

    Science.gov (United States)

    Choi, Jae Moon; Lee, Yoon Kyung; Yoo, Hwanhee; Lee, Sukyung; Kim, Hee Yeong; Kim, Young-Kug

    2016-01-01

    Intraoperative blood transfusion increases the risk for perioperative mortality and morbidity in liver transplant recipients. A high stroke volume variation (SVV) method has been proposed to reduce blood loss during living donor hepatectomy. Herein, we investigated whether maintaining high SVV could reduce the need for blood transfusion and also evaluated the effect of the high SVV method on postoperative outcomes in liver transplant recipients. We retrospectively analyzed 332 patients who underwent liver transplantation, divided into control (maintaining blood transfusion requirement and hemodynamic parameters, including SVV, as well as postoperative outcomes, such as incidences of acute kidney injury, durations of postoperative intensive care unit and hospital stay, and rates of 1-year mortality. Mean SVV values were 7.0% ± 1.3% in the control group (n = 288) and 11.2% ± 1.8% in the high SVV group (n = 44). The median numbers of transfused packed red blood cells and fresh frozen plasmas in the high SVV group were significantly lower than those in control group (0 vs. 2 units, P = 0.003; and 0 vs. 3 units, P = 0.033, respectively). No significant between-group differences were observed for postoperative outcomes. Maintaining high SVV can reduce the blood transfusion requirement during liver transplantation without worsening postoperative outcomes. These findings provide insights into improving perioperative management in liver transplant recipients.

  11. Validation of tomographic measurement of cerebral blood volume with C-11-labeled carboxyhemoglobin

    International Nuclear Information System (INIS)

    Phelps, M.E.; Huang, S.C.; Hoffman, E.J.; Kuhl, D.E.

    1979-01-01

    Red blood cells, tagged with C-11 administration of 11 CO gas, have been used to portray the distribution of blood in the brain. To date, however, the accuracy of this approach has not been validated. We have performed in vitro measurements of regional cerebral blood volume (CBV) with red blood cells labeled with C-11 and Cr-51 in four dogs and two rhesus monkeys. These studies yielded a ratio of CBV/sub C-1/ to CBV/sub Cr-11/ of 1.02 +- 0.03 (s.d.) from 92 samples. A least-squares fit to these data showed CBV/sub C-11/ = 1.01 CBV/sub Cr-51/ + 0.037; P much 11 CO-RBC gave coefficients of variation of +- 2.8% and +- 4.8% for cross-sectional CBV and regional (approx.4 cm 2 ) CBV over an 80-min period. The average human CBV was found to be 4.2 +- 0.4 cc blood per 100 g tissue. Clear tomographic delineation of the distribution of CBV in human subjects is achieved with ECT, which provides a ''live'' measurement of this parameter of cerebral hemodynamics. These data demonstrate that 11 CO administered by single-breath inhalation is a reliable and accurate blood tracer for measurement of CBV with ECT

  12. STS-42 MS Readdy conducts blood volume test on OV-103's middeck

    Science.gov (United States)

    1992-01-01

    STS-42 Mission Specialist (MS) William F. Readdy, using intravehicular activity (IVA) foot restraints, studies a checklist as he measures the veins in his lower right leg on the middeck of Discovery, Orbiter Vehicle (OV) 103. Readdy uses an electronic monitor and a pair of large blood pressure cuffs that encircle the thigh and calf. Changes in blood volume are determined by inflating the cuffs which then alters the blood pressure. The tone of the veins was monitored before and during the flight and will be measured following the eight-day mission. Behind Readdy are the forward lockers with combuster analyzer, checklists, communications kit assemblies, and spotmeter attached. At Readdy's left is the sleep station along the starboard wall.

  13. Quantitative agreement between [(15)O]H2O PET and model free QUASAR MRI-derived cerebral blood flow and arterial blood volume

    NARCIS (Netherlands)

    Heijtel, D. F. R.; Petersen, E. T.; Mutsaerts, H. J. M. M.; Bakker, E.; Schober, P.; Stevens, M. F.; van Berckel, B. N. M.; Majoie, C. B. L. M.; Booij, J.; van Osch, M. J. P.; van Bavel, E. T.; Boellaard, R.; Lammertsma, A. A.; Nederveen, A. J.

    2016-01-01

    The purpose of this study was to assess whether there was an agreement between quantitative cerebral blood flow (CBF) and arterial cerebral blood volume (CBVA) measurements by [(15)O]H2O positron emission tomography (PET) and model-free QUASAR MRI. Twelve healthy subjects were scanned within a week

  14. Volume-dependent K+ transport in rabbit red blood cells comparison with oxygenated human SS cells

    Energy Technology Data Exchange (ETDEWEB)

    Al-Rohil, N.; Jennings, M.L.

    1989-07-01

    In this study the volume-dependent or N-ethylmaleimide (NEM)-stimulated, ouabain-insensitive K+ influx and efflux were measured with the tracer 86Rb+ in rabbit red blood cells. The purpose of the work was to examine the rabbit as a potential model for cell volume regulation in human SS red blood cells and also to investigate the relationship between the NEM-reactive sulfhydryl group(s) and the signal by which cell swelling activates the transport. Ouabain-resistant K+ efflux and influx increase nearly threefold in cells swollen hypotonically by 15%. Pretreatment with 2 mM NEM stimulates efflux 5-fold and influx 10-fold (each measured in an isotonic medium). The ouabain-resistant K+ efflux was dependent on the major anion in the medium. The anion dependence of K+ efflux in swollen or NEM-stimulated cells was as follows: Br- greater than Cl- much greater than NO3- = acetate. The magnitudes of both the swelling- and the NEM-stimulated fluxes are much higher in young cells (density separated but excluding reticulocytes) than in older cells. Swelling- or NEM-stimulated K+ efflux in rabbit red blood cells was inhibited 50% by 1 mM furosemide, and the inhibitory potency of furosemide was enhanced by extracellular K+, as is known to be true for human AA and low-K+ sheep red blood cells. The swelling-stimulated flux in both rabbit and human SS cells has a pH optimum at approximately 7.4. We conclude that rabbit red blood cells are a good model for swelling-stimulated K+ transport in human SS cells.

  15. Impedance cardiography: Pulsatile blood flow and the biophysical and electrodynamic basis for the stroke volume equations

    Directory of Open Access Journals (Sweden)

    Donald P Bernstein

    2010-01-01

    Full Text Available Impedance cardiography (ICG is a branch of bioimpedance pimarily concerned with the determination of left ventricular stroke volume (SV. As implemented, using the transthoracic approach, the technique involves applying a current field longitudinally across a segment of thorax by means of a constant magnitude, high frequency, low amplitude alternating current (AC. By Ohm's Law, the voltage difference measured within the current field is proportional to the electrical impedance Z (Ω. Without ventilatory or cardiac activity, Z is known as the transthoracic, static base impedance Z0. Upon ventricular ejection, a characteristic time dependent cardiac-synchronous pulsatile impedance change is obtained, ΔZ(t, which, when placed electrically in parallel with Z0, constitutes the time-variable total transthoracic impedance Z(t. ΔZ(t represents a dual-element composite waveform, which comprises both the radially-oriented volumetric expansion of and axially-directed forward blood flow within both great thoracic arteries. In its majority, however, ΔZ(t is known to primarily emanate from the ascending aorta. Conceptually, commonly implemented methods assume a volumetric origin for the peak systolic upslope of ΔZ(t, (i.e. dZ/dtmax, with the presumed units of Ω·s-1. A recently introduced method assumes the rapid ejection of forward flowing blood in earliest systole causes significant changes in the velocity-induced blood resistivity variation (Δρb(t, Ωcm·s-1, and it is the peak rate of change of the blood resistivity variation dρb(t/dtmax (Ωcm·s-2 that is the origin of dZ/dtmax. As a consequence of dZ/dtmax peaking in the time domain of peak aortic blood acceleration, dv/dtmax (cm·s-2, it is suggested that dZ/dtmax is an ohmic mean acceleration analog (Ω·s-2 and not a mean flow or velocity surrogate as generally assumed. As conceptualized, the normalized value, dZ/dtmax/Z0, is a dimensionless ohmic mean acceleration equivalent (s-2

  16. Cardiac variation of inferior vena cava: new concept in the evaluation of intravascular blood volume.

    Science.gov (United States)

    Nakamura, Kensuke; Tomida, Makoto; Ando, Takehiro; Sen, Kon; Inokuchi, Ryota; Kobayashi, Etsuko; Nakajima, Susumu; Sakuma, Ichiro; Yahagi, Naoki

    2013-07-01

    Evaluation of the intravascular blood volume is an important assessment in emergency and critical care medicine. Measurement of the inferior vena cava (IVC) respiratory variation by ultrasound echography is useful, but it entails subjective problems. We have hypothesized that IVC cardiac variation is also correlated with intravascular blood volume and analyzed it automatically using computer software of two kinds, later comparing the results. Snakes, software to track boundaries by curve line continuity, and template matching software were incorporated into a computer with an ultrasound machine to track the short-axis view of IVC automatically and analyze it with approximation by ellipse. Eight healthy volunteers with temporary mild hypovolemia underwent echography before and after passive leg raising and while wearing medical anti-shock trousers. IVC cardiac variation was visually decreased by both leg raising and medical anti-shock trousers. The collapse index (maximum - minimum/maximum) of area during three cardiac beats was decreased showing a good relationship to fluid load simulations; 0.24 ± 0.03 at baseline versus 0.11 ± 0.01 with leg raising and 0.12 ± 0.01 with medical anti-shock trousers. In conclusion, IVC cardiac variation has the potential to provide an evaluation of water volume. It presents some advantages in mechanical analysis over respiratory variation. At the very least, we need to exercise some caution with cardiac variation when evaluating respiratory variation.

  17. Blood products, volume control, and renal support in the coagulopathy of liver disease.

    Science.gov (United States)

    Argo, Curtis K; Balogun, Rasheed A

    2009-02-01

    Plasma-based products are commonly used in patients who have chronic liver disease to treat perceived coagulopathy despite unproven efficacy and potentially severe risks, such as transfusion-related acute lung injury, which carries a high mortality rate. Moreover, volume expansion may acutely worsen portal hypertension and increase bleeding from the collateral portal vascular bed. Although factor replacement therapy may be warranted in selected situations, its use should be restricted because of the limitations of target tests, such as international normalized ratio, which poorly reflects presence of bleeding diatheses in patients who have cirrhosis. Renal replacement therapies are frequent adjuncts in patients who have cirrhosis and are acutely decompensated, and may correct uremia-related bleeding diathesis and assist in controlling vascular volume, although they are generally limited to use as a bridge to liver transplantation. Novel extracorporeal therapies are emerging and may also have significant interaction with the hemostatic system. Volume contraction and blood conservation therapies are relatively new and promising approaches to reduce use of blood products in liver transplantation.

  18. Variation of Red Blood Cell Distribution Width and Mean Platelet Volume after Moderate Endurance Exercise

    Directory of Open Access Journals (Sweden)

    Giuseppe Lippi

    2014-01-01

    Full Text Available Although physical exercise strongly influences several laboratory parameters, data about the hematological changes after medium distance running are scarce. We studied 31 middle-trained athletes (mean training regimen 217±32 min/week who performed a 21.1 km, half-marathon run. Blood samples were collected before the run, at the end, and 3 and 20 hours thereafter. The complete blood count was performed on Advia 2120 and included red blood cell (RBC, reticulocyte, and platelet counts; hemoglobin; mean corpuscular volume (MCV; mean corpuscular hemoglobin (MCH; reticulocyte haemoglobin content (Ret CHR; RBC distribution width (RDW, mean platelet volume (MPV. No significant variations were observed for MCH and Ret CHR. The RBC, reticulocyte, and hemoglobin values modestly decreased after the run. The MCV significantly increased at the end of running but returned to baseline 3 hours thereafter. The RDW constantly increased, reaching a peak 20 hours after the run. The platelet count and MPV both increased after the run and returned to baseline 3 hours thereafter. These results may have implications for definition of reference ranges and antidoping testing, and may also contribute to explaining the relationship between endurance exercise and mortality, since previous studies reported that RDW and MPV may be significantly associated with cardiovascular disease.

  19. System modeling and identification in indicator dilution method for assessment of ejection fraction and pulmonary blood volume

    NARCIS (Netherlands)

    Bharath, H.N.; Prabhu, K.M.M.; Korsten, H.H.M.; Mischi, M.

    2012-01-01

    Clinically relevant cardiovascular parameters, such as pulmonary blood volume (PBV) and ejection fraction (EF), can be assessed through indicator dilution techniques. Among these techniques, which are typically invasive due to the need for central catheterization, contrast ultrasonography provides a

  20. Rapid multi-wavelength optical assessment of circulating blood volume without a priori data

    Science.gov (United States)

    Loginova, Ekaterina V.; Zhidkova, Tatyana V.; Proskurnin, Mikhail A.; Zharov, Vladimir P.

    2016-03-01

    The measurement of circulating blood volume (CBV) is crucial in various medical conditions including surgery, iatrogenic problems, rapid fluid administration, transfusion of red blood cells, or trauma with extensive blood loss including battlefield injuries and other emergencies. Currently, available commercial techniques are invasive and time-consuming for trauma situations. Recently, we have proposed high-speed multi-wavelength photoacoustic/photothermal (PA/PT) flow cytometry for in vivo CBV assessment with multiple dyes as PA contrast agents (labels). As the first step, we have characterized the capability of this technique to monitor the clearance of three dyes (indocyanine green, methylene blue, and trypan blue) in an animal model. However, there are strong demands on improvements in PA/PT flow cytometry. As additional verification of our proof-of-concept of this technique, we performed optical photometric CBV measurements in vitro. Three label dyes—methylene blue, crystal violet and, partially, brilliant green—were selected for simultaneous photometric determination of the components of their two-dye mixtures in the circulating blood in vitro without any extra data (like hemoglobin absorption) known a priori. The tests of single dyes and their mixtures in a flow system simulating a blood transfusion system showed a negligible difference between the sensitivities of the determination of these dyes under batch and flow conditions. For individual dyes, the limits of detection of 3×10-6 M‒3×10-6 M in blood were achieved, which provided their continuous determination at a level of 10-5 M for the CBV assessment without a priori data on the matrix. The CBV assessment with errors no higher than 4% were obtained, and the possibility to apply the developed procedure for optical photometric (flow cytometry) with laser sources was shown.

  1. Minimal volume regulation after shrinkage of red blood cells from five species of reptiles

    DEFF Research Database (Denmark)

    Kristensen, Karina; Berenbrink, Michael; Koldkjær, Pia

    2008-01-01

    Red blood cells (RBCs) from most vertebrates restore volume upon hypertonic shrinkage and the mechanisms underlying this regulatory volume increase (RVI) have been studied extensively in these cells. Despite the phylogenetically interesting position of reptiles, very little is known about their red...... cell function. The present study demonstrates that oxygenated RBCs in all major groups of reptiles exhibit no or a very reduced RVI upon ~ 25% calculated hyperosmotic shrinkage. Thus, RBCs from the snakes Crotalus durissus and Python regius, the turtle Trachemys scripta and the alligator Alligator...... was not characterized. It seems, therefore, that the RVI response based on NHE activation was lost among the early sauropsids that gave rise to modern reptiles and birds, while it was retained in mammals. An RVI response has then reappeared in birds, but based on activation of the NKCC. Alternatively, the absence...

  2. Measurement of hepatic volume and effective blood flow with radioactive colloids: Evaluation of development in liver diseases

    International Nuclear Information System (INIS)

    Fujii, M.; Uchino, H.; Kyoto Univ.

    1982-01-01

    Changes in hepatic volume and the blood flow effectively perfusing the liver parenchyma were studied as an assessment of the severity of liver diseases. Hepatic effective blood flow was estimated as the hepatic fractional clearance of radioactive colloids, obtained from the disappearance rate multiplied by the fraction of injected dose taken up by the liver. The hepatic fractional clearance was normal or not markedly decreased in patients with acute hepatitis which had developed favorably, but was severely decreased in patients with fulminant hepatitis. In liver diseases, the ratio of hepatic volume to fractional clearance was found to increase as the clearance decreased. In subjects with normal clearance, hepatic fractional clearance was correlated significantly with liver volume, indicating that hepatic effective blood flow is proportional to parenchymal volume in an unanesthetized, resting state. In biopsied cases changes in volume and blood flow accorded well with changes indicated by morphological criteria. In chronic persistent hepatitis, effective hepatic blood flow is not diminished. However, hepatic blood flow were observed between the cirrhosis or chronic aggressive hepatitis, and normal control groups. Extension of chronic inflammatory infiltration into the parenchyma distinguishes chronic aggressive hepatitis from chronic persistent hepatitis. Architecture is often disturbed in the former. These changes should be accompanied by disturbance of microcirculation. The present study indicates that the decrease in effective hepatic blood flow in chronic hepatitis and cirrhosis has two aspects: one is a summation of microcirculatory disturbances, and the other is a decrease in liver cell mass. (orig.)

  3. Susceptibility contrast imaging of CO2-induced changes in the blood volume of the human brain

    DEFF Research Database (Denmark)

    Rostrup, Egill; Larsson, H B; Toft, P B

    1996-01-01

    PURPOSE: To investigate changes in the regional cerebral blood volume (rCBV) in human subjects during rest and hypercapnia by MR imaging, and to compare the results from contrast-enhanced and noncontrast-enhanced susceptibility-weighted imaging. MATERIAL AND METHODS: Five healthy volunteers (aged...... to be in accordance with results obtained by other methods. Noncontrast functional MR (fMR) imaging showed signal increases in gray matter, but also inconsistent changes in some white matter regions. CONCLUSION: In this experiment, contrast-enhanced imaging seemed to show a somewhat higher sensitivity towards changes...

  4. Quantitation of cerebral blood volume by 99mTc-DTPA-HSA SPECT

    International Nuclear Information System (INIS)

    Inoue, Yusuke; Machida, Kikuo; Momose, Toshimitsu

    1992-01-01

    The characteristics of technetium-99m diethylenetriaminepentaacetic acid human serum albumin ( 99m Tc-DTPA-HSA) as an agent for quantitation of cerebral blood volume (CBV) were examined. The radioactivity after decay correction as a percentage of the activity at 10 minutes was 84.3±1.3% at 120 minutes after the injection of 99m Tc-DTPA-HSA. Radioactivity was found exclusively in plasma, with little in blood cells. The blood retention of 99m Tc-DTPA-HSA is sufficient, and its use in the quantitation of CBV omits the need for centrifugation of the blood sample. CBV quantified using the tracer and a SPECT system with a single-head rotating gamma camera was 4.09±0.60 ml/100g brain, similar to values reported previously. Two serial SPECT scans provided similar images, and the CBV values determined by the two scans were closely correlated (p 99m Tc-DTPA-HSA has useful properties for quantitative CBV measurement and that quantitation of CBV by 99m Tc-DTPA-HSA SPECT is feasible using a system with a single-head rotating gamma camera. (author)

  5. Effects of local single and fractionated X-ray doses on rat bone marrow blood flow and red blood cell volume

    International Nuclear Information System (INIS)

    Pitkaenen, M.A.; Hopewell, J.W.

    1985-01-01

    Time and dose dependent changes in blood flow and red blood cell volume were studied in the locally irradiated bone marrow of the rat femur after single and fractionated doses of X-rays. With the single dose of 10 Gy the bone marrow blood flow although initially reduced returned to the control levels by seven months after irradiation. With doses >=15 Gy the blood flow was still significantly reduced at seven months. The total dose levels predicted by the nominal standard dose equation for treatments in three, six or nine fractions produced approximately the same degree of reduction in the bone marrow blood flow seven months after the irradiation. However, the fall in the red blood cell volume was from 23 to 37% greater in the three fractions groups compared with that in the nine fractions groups. Using the red blood cell volume as a parameter the nominal standard dose formula underestimated the severity of radiation damage in rat bone marrow at seven months for irradiation with small numbers of large dose fractions. (orig.) [de

  6. Quantified measurement of brain blood volume: comparative evaluations between the single photon emission computer tomography and the positron computer tomography

    International Nuclear Information System (INIS)

    Bouvard, G.; Fernandez, Y.; Petit-Taboue, M.C.; Derlon, J.M.; Travere, J.M.; Le Poec, C.

    1991-01-01

    The quantified measurement of cerebral blood volume is interesting for the brain blood circulation studies. This measurement is often used in positron computed tomography. It's more difficult in single photon emission computed tomography: there are physical problems with the limited resolution of the detector, the Compton effect and the photon attenuation. The objectif of this study is to compare the results between these two techniques. The quantified measurement of brain blood volume is possible with the single photon emission computer tomogragry. However, there is a loss of contrast [fr

  7. Magnetic resonance imaging as a diagnostic method for assessing function. New procedures for the non-invasive quantification of cerebral blood volume and blood flow

    International Nuclear Information System (INIS)

    Gueckel, F.; Rempp, K.; Becker, G.; Koepke, J.; Loose, R.; Brix, G.

    1994-01-01

    This paper presents a brief introduction to the current status of cerebral blood volume and blood flow imaging with magnetic resonance imaging (MRI) techniques. A new method for the quantitative assessment of regional cerebral blood volume (rCBV) and regional cerebral blood flow (rCBF) on the basis of the indicator dilution theory is described and preliminary quantitative results from healthy volunteers are presented. The mean values for the rCBV are 8,27±1,85 ml/100 g for grey matter and 3,78±1,34 ml/100 g for white matter. The mean values for the rCBF are 44,8±11,29 ml/min/100 g for the grey matter and 20,88±8,42 ml/min/100 g for the white matter. These results are in good agreement with PET results from the literature. (orig.) [de

  8. Scintigraphic method for evaluating reductions in local blood volumes in human extremities

    DEFF Research Database (Denmark)

    Blønd, L; Madsen, Jan Lysgård

    2000-01-01

    were carried out. No significant differences between results obtained by the use of one or two scintigraphic projections were found. The between-subject coefficient of variation was 14% in the lower limb experiment and 11% in the upper limb experiment. The within-subject coefficient of variation was 6......% in the lower limb experiment and 6% in the upper limb experiment. We found a significant relation (r = 0.42, p = 0.018) between the results obtained by the scintigraphic method and the plethysmographic method. In fractions, a mean reduction in blood volume of 0.49+0.14 (2 SD) was found after 1 min of elevation...... of the lower limb and a mean reduction of 0.45+/-0.10 (2 SD) after half a minute of elevation of the upper limb. We conclude that the method is precise and can be used in investigating physiologic and pathophysiologic mechanisms in relation to blood volumes of limbs not subject to research previously....

  9. Prefrontal cerebral blood volume patterns while playing video games--a near-infrared spectroscopy study.

    Science.gov (United States)

    Nagamitsu, Shinichiro; Nagano, Miki; Yamashita, Yushiro; Takashima, Sachio; Matsuishi, Toyojiro

    2006-06-01

    Video game playing is an attractive form of entertainment among school-age children. Although this activity reportedly has many adverse effects on child development, these effects remain controversial. To investigate the effect of video game playing on regional cerebral blood volume, we measured cerebral hemoglobin concentrations using near-infrared spectroscopy in 12 normal volunteers consisting of six children and six adults. A Hitachi Optical Topography system was used to measure hemoglobin changes. For all subjects, the video game Donkey Kong was played on a Game Boy device. After spectroscopic probes were positioned on the scalp near the target brain regions, the participants were asked to play the game for nine periods of 15s each, with 15-s rest intervals between these task periods. Significant increases in bilateral prefrontal total-hemoglobin concentrations were observed in four of the adults during video game playing. On the other hand, significant decreases in bilateral prefrontal total-hemoglobin concentrations were seen in two of the children. A significant positive correlation between mean oxy-hemoglobin changes in the prefrontal region and those in the bilateral motor cortex area was seen in adults. Playing video games gave rise to dynamic changes in cerebral blood volume in both age groups, while the difference in the prefrontal oxygenation patterns suggested an age-dependent utilization of different neural circuits during video game tasks.

  10. Assessment of red blood cell distribution width and mean platelet volume in children with epistaxis.

    Science.gov (United States)

    Üstün Bezgin, Selin; Çakabay, Taliye; Odaman Al, Işık

    2017-04-01

    This study aimed to investigate whether there is a relationship between red blood cell distribution width, mean platelet volume and epistaxis in children. Between January 2015 and July 2016, 105 children who were referred to our clinic with epistaxis and 100 sex- and age-matched controls were retrospectively analyzed. Red blood cell distribution width (RDW) and mean platelet volume (MPV) values were determined in both groups. RDW values were found significantly (P epistaxis than in the control group (11.95 ± 1.31 vs. 12.74 ± 1.21). MPV was 7.49 ± 1.33 in the group with epistaxis and 7.23 ± 1.06 in the control group, and there was no significant difference between the groups (p > 0.05). We found no difference between MPV values of both groups and significantly lower RDW values in children with epistaxis. Decreased RDW values were considered as an accompanying marker rather than a result of epistaxis. In addition, it may be thought that low RDW values may increase the bleeding tendency by disrupting the thrombotic activities. Further studies are needed to validate the relation of these parameters with epistaxis and its mechanisms. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Measurement of brain perfusion, blood volume, and blood-brain barrier permeability, using dynamic contrast-enhanced T(1)-weighted MRI at 3 tesla

    DEFF Research Database (Denmark)

    Larsson, Henrik B W; Courivaud, Frédéric; Rostrup, Egill

    2009-01-01

    Assessment of vascular properties is essential to diagnosis and follow-up and basic understanding of pathogenesis in brain tumors. In this study, a procedure is presented that allows concurrent estimation of cerebral perfusion, blood volume, and blood-brain permeability from dynamic T(1)-weighted...... on a pixel-by-pixel basis of cerebral perfusion, cerebral blood volume, and blood-brain barrier permeability.......Assessment of vascular properties is essential to diagnosis and follow-up and basic understanding of pathogenesis in brain tumors. In this study, a procedure is presented that allows concurrent estimation of cerebral perfusion, blood volume, and blood-brain permeability from dynamic T(1)-weighted...... imaging of a bolus of a paramagnetic contrast agent passing through the brain. The methods are applied in patients with brain tumors and in healthy subjects. Perfusion was estimated by model-free deconvolution using Tikhonov's method (gray matter/white matter/tumor: 72 +/- 16/30 +/- 8/56 +/- 45 mL/100 g...

  12. Blood Volume: Importance and Adaptations to Exercise Training, Environmental Stresses and Trauma/Sickness

    Science.gov (United States)

    Sawka, Michael N.; Convertino, Victor A.; Eichner, E. Randy; Schnieder, Suzanne M.; Young, Andrew J.

    2000-01-01

    This paper reviews the influence of several perturbations (physical exercise, heat stress, terrestrial altitude, microgravity, and trauma/sickness) on adaptations of blood volume (BV), erythrocyte volume (EV), and plasma volume (PV). Exercise training can induced BV expansion; PV expansion usually occurs immediately, but EV expansion takes weeks. EV and PV expansion contribute to aerobic power improvements associated with exercise training. Repeated heat exposure induces PV expansion but does not alter EV. PV expansion does not improve thermoregulation, but EV expansion improves thermoregulation during exercise in the heat. Dehydration decreases PV (and increases plasma tonicity) which elevates heat strain and reduces exercise performance. High altitude exposure causes rapid (hours) plasma loss. During initial weeks at altitude, EV is unaffected, but a gradual expansion occurs with extended acclimatization. BV adjustments contribute, but are not key, to altitude acclimatization. Microgravity decreases PV and EV which contribute to orthostatic intolerance and decreased exercise capacity in astronauts. PV decreases may result from lower set points for total body water and central venous pressure, which EV decrease bay result form increased erythrocyte destruction. Trauma, renal disease, and chronic diseases cause anemia from hemorrhage and immune activation, which suppressions erythropoiesis. The re-establishment of EV is associated with healing, improved life quality, and exercise capabilities for these injured/sick persons.

  13. Measuring Blood Glucose Concentrations in Photometric Glucometers Requiring Very Small Sample Volumes.

    Science.gov (United States)

    Demitri, Nevine; Zoubir, Abdelhak M

    2017-01-01

    Glucometers present an important self-monitoring tool for diabetes patients and, therefore, must exhibit high accuracy as well as good usability features. Based on an invasive photometric measurement principle that drastically reduces the volume of the blood sample needed from the patient, we present a framework that is capable of dealing with small blood samples, while maintaining the required accuracy. The framework consists of two major parts: 1) image segmentation; and 2) convergence detection. Step 1 is based on iterative mode-seeking methods to estimate the intensity value of the region of interest. We present several variations of these methods and give theoretical proofs of their convergence. Our approach is able to deal with changes in the number and position of clusters without any prior knowledge. Furthermore, we propose a method based on sparse approximation to decrease the computational load, while maintaining accuracy. Step 2 is achieved by employing temporal tracking and prediction, herewith decreasing the measurement time, and, thus, improving usability. Our framework is tested on several real datasets with different characteristics. We show that we are able to estimate the underlying glucose concentration from much smaller blood samples than is currently state of the art with sufficient accuracy according to the most recent ISO standards and reduce measurement time significantly compared to state-of-the-art methods.

  14. Evaluation of low red blood cell mean corpuscular volume in an apheresis donor population.

    Science.gov (United States)

    Bryant, Barbara J; Hopkins, Julie A; Arceo, Sarah M; Leitman, Susan F

    2009-09-01

    Apheresis donors are routinely evaluated with a complete blood count (CBC). Low red blood cell mean corpuscular volume (MCV) values (or=12.5 g/dL) could be due to iron deficiency or hemoglobinopathy. The etiology of a low MCV in a healthy apheresis donor population was assessed. Predonation samples for CBC were obtained from 1162 consecutive apheresis donors. Donors with a MCV of less than 80 fL were evaluated by CBC, iron studies (ferritin, serum iron, transferrin, percentage of transferrin saturation), and hemoglobin (Hb) electrophoresis. Iron deficiency was defined as a ferritin value below the reference range. Beta chain Hb variants were determined by Hb electrophoresis. Alpha thalassemia trait was presumed if the red blood cell (RBC) count was elevated, no variant Hbs were detected, and the iron studies were within normal ranges. In a 19-month period, 33 of 1162 apheresis donors had low MCV values. Iron deficiency was present in 64%; 49% had isolated iron deficiency and 15% had iron deficiency plus hemoglobinopathy. Hemoglobinopathy without concomitant iron deficiency was found in the remaining 36%. Iron deficiency is present in the majority of apheresis donors with repeatedly low MCV values and Hb levels of 12.5 g/dL or more. Hemoglobinopathy is also commonly present but may not be easily recognized in the setting of iron deficiency. The MCV is a useful screening tool to detect iron deficiency and hemoglobinopathy. Low MCV values should be investigated to determine if iron replacement therapy is indicated.

  15. Regional Myocardial Blood Volume and Flow: First-Pass MR Imaging with Polylysine-Gd-DTPA

    Science.gov (United States)

    Wilke, Norbert; Kroll, Keith; Merkle, Hellmut; Wang, Ying; Ishibashi, Yukata; Xu, Ya; Zhang, Jiani; Jerosch-Herold, Michael; Mühler, Andreas; Stillman, Arthur E.; Bassingthwaighte, James B.; Bache, Robert; Ugurbil, Kamil

    2010-01-01

    The authors investigated the utility of an intravascular magnetic resonance (MR) contrast agent, poly-L-lysine-gadolinium diethylenetriaminepentaacetic acid (DTPA), for differentiating acutely ischemic from normally perfused myocardium with first-pass MR imaging. Hypoperfused regions, identified with microspheres, on the first-pass images displayed significantly decreased signal intensities compared with normally perfused myocardium (P < .0007). Estimates of regional myocardial blood content, obtained by measuring the ratio of areas under the signal intensity-versus-time curves in tissue regions and the left ventricular chamber, averaged 0.12 mL/g ± 0.04 (n = 35), compared with a value of 0.11 mL/g ± 0.05 measured with radiolabeled albumin in the same tissue regions. To obtain MR estimates of regional myocardial blood flow, in situ calibration curves were used to transform first-pass intensity-time curves into content-time curves for analysis with a multiple-pathway, axially distributed model. Flow estimates, obtained by automated parameter optimization, averaged 1.2 mL/min/g ± 0.5 [n = 29), compared with 1.3 mL/min/g ± 0.3 obtained with tracer microspheres in the same tissue specimens at the same time. The results represent a combination of T1-weighted first-pass imaging, intravascular relaxation agents, and a spatially distributed perfusion model to obtain absolute regional myocardial blood flow and volume. PMID:7766986

  16. Prediction of Packed Cell Volume after Whole Blood Transfusion in Small Ruminants and South American Camelids: 80 Cases (2006-2016).

    Science.gov (United States)

    Luethy, D; Stefanovski, D; Salber, R; Sweeney, R W

    2017-11-01

    Calculation of desired whole blood transfusion volume relies on an estimate of an animal's circulating blood volume, generally accepted to be 0.08 L/kg or 8% of the animal's body weight in kilograms. To use packed cell volume before and after whole blood transfusion to evaluate the accuracy of a commonly used equation to predict packed cell volume after transfusion in small ruminants and South American camelids; to determine the nature and frequency of adverse transfusion reactions in small ruminants and camelids after whole blood transfusion. Fifty-eight small ruminants and 22 alpacas that received whole blood transfusions for anemia. Retrospective case series; medical record review for small ruminants and camelids that received whole blood transfusions during hospitalization. Mean volume of distribution of blood as a fraction of body weight in sheep (0.075 L/kg, 7.5% BW) and goats (0.076 L/kg, 7.6% BW) differed significantly (P blood volume (volume of distribution of blood) is adequate for calculation of transfusion volumes; however, use of the species-specific circulating blood volume can improve calculation of transfusion volume to predict and achieve desired packed cell volume. The incidence of transfusion reactions in small ruminants and camelids is low. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  17. Does Preinterventional Flat-Panel Computer Tomography Pooled Blood Volume Mapping Predict Final Infarct Volume After Mechanical Thrombectomy in Acute Cerebral Artery Occlusion?

    International Nuclear Information System (INIS)

    Wagner, Marlies; Kyriakou, Yiannis; Mesnil de Rochemont, Richard du; Singer, Oliver C.; Berkefeld, Joachim

    2013-01-01

    PurposeDecreased cerebral blood volume is known to be a predictor for final infarct volume in acute cerebral artery occlusion. To evaluate the predictability of final infarct volume in patients with acute occlusion of the middle cerebral artery (MCA) or the distal internal carotid artery (ICA) and successful endovascular recanalization, pooled blood volume (PBV) was measured using flat-panel detector computed tomography (FPD CT).Materials and MethodsTwenty patients with acute unilateral occlusion of the MCA or distal ACI without demarcated infarction, as proven by CT at admission, and successful Thrombolysis in cerebral infarction score (TICI 2b or 3) endovascular thrombectomy were included. Cerebral PBV maps were acquired from each patient immediately before endovascular thrombectomy. Twenty-four hours after recanalization, each patient underwent multislice CT to visualize final infarct volume. Extent of the areas of decreased PBV was compared with the final infarct volume proven by follow-up CT the next day.ResultsIn 15 of 20 patients, areas of distinct PBV decrease corresponded to final infarct volume. In 5 patients, areas of decreased PBV overestimated final extension of ischemia probably due to inappropriate timing of data acquisition and misery perfusion.ConclusionPBV mapping using FPD CT is a promising tool to predict areas of irrecoverable brain parenchyma in acute thromboembolic stroke. Further validation is necessary before routine use for decision making for interventional thrombectomy

  18. Photoplethysmography for blood volumes and oxygenation changes during intermittent vascular occlusions.

    Science.gov (United States)

    Abay, T Y; Kyriacou, P A

    2018-06-01

    Photoplethysmography (PPG) is an optical technique that measures blood volume variations. The main application of dual-wavelength PPG is pulse oximetry, in which the arterial oxygen saturation (SpO[Formula: see text]) is calculated noninvasively. However, the PPG waveform contains other significant physiological information that can be used in conjunction to SpO[Formula: see text] for the assessment of oxygenation and blood volumes changes. This paper investigates the use of near infrared spectroscopy (NIRS) processing techniques for extracting relative concentration changes of oxygenated ([Formula: see text]HbO[Formula: see text]), reduced ([Formula: see text]HHb) and total haemoglobin ([Formula: see text]tHb) from dual-wavelength PPG signals during intermittent pressure-increasing vascular occlusions. A reflectance PPG sensor was attached on the left forearm of nineteen (n = 19) volunteers, along with a reference NIRS sensor positioned on the same forearm, above the left brachioradialis. The investigation protocol consisted of seven intermittent and pressure-increasing vascular occlusions. Relative changes in haemoglobin concentrations were obtained by applying the modified Beer-Lambert law to PPG signals, while oxygenation changes were estimated by the difference between red and infrared attenuations of DC PPGs (A[Formula: see text] = [Formula: see text]A[Formula: see text] - [Formula: see text]A[Formula: see text]) and by the conventional SpO[Formula: see text]. The [Formula: see text]HbO[Formula: see text], [Formula: see text]HHb, [Formula: see text]tHb from the PPG signals indicated significant changes in perfusion induced by either partial and complete occlusions (p < 0.05). The trends in the variables extracted from PPG showed good correlation with the same parameters measured by the reference NIRS monitor. Bland and Altman analysis of agreement between PPG and NIRS showed underestimation of the magnitude of changes by the PPG. A[Formula: see text

  19. Regional blood flow analysis and its relationship with arterial branch lengths and lumen volume in the coronary arterial tree

    International Nuclear Information System (INIS)

    Molloi, Sabee; Wong, Jerry T

    2007-01-01

    The limitations of visually assessing coronary artery disease are well known. These limitations are particularly important in intermediate coronary lesions (30-70% diameter stenosis) where it is difficult to determine whether a particular lesion is the cause of ischaemia. Therefore, a functional measure of stenosis severity is needed. The purpose of this study is to determine whether the expected maximum coronary blood flow in an arterial tree is predictable from its sum of arterial branch lengths or lumen volume. Using a computer model of a porcine coronary artery tree, an analysis of blood flow distribution was conducted through a network of millions of vessels that included the entire coronary artery tree down to the first capillary branch. The flow simulation results show that there is a linear relationship between coronary blood flow and the sum of its arterial branch lengths. This relationship holds over the entire arterial tree. The flow simulation results also indicate that there is a 3/4 er relation between coronary blood flow (Q) and the sum of its arterial lumen volume (V). Moreover, there is a linear relationship between normalized Q and normalized V raised to a power of 3/4 over the entire arterial tree. These results indicate that measured arterial branch lengths or lumen volumes can be used to predict the expected maximum blood flow in an arterial tree. This theoretical maximum blood flow, in conjunction with an angiographically measured blood flow, can potentially be used to calculate fractional flow reserve based entirely on angiographic data

  20. Sleep apnea termination decreases cerebral blood volume: a near-infrared spectroscopy case study

    Science.gov (United States)

    Virtanen, Jaakko; Noponen, Tommi; Salmi, Tapani; Toppila, Jussi; Meriläinen, Pekka

    2009-07-01

    Medical near-infrared spectroscopy (NIRS) can be used to estimate cerebral haemodynamic changes non-invasively. Sleep apnea is a common sleep disorder where repetitive pauses in breathing decrease the quality of sleep and exposes the individual to various health problems. We have measured oxygenated and deoxygenated haemoglobin concentration changes during apneic events in sleep from the forehead of one subject using NIRS and used principal component analysis to extract extracerebral and cortical haemodynamic changes from NIRS signals. Comparison of NIRS signals with EEG, bioimpedance, and pulse oximetry data suggests that termination of apnea leads to decreases in cerebral blood volume and flow that may be related to neurological arousal via neurovascular coupling.

  1. Precision of a new bedside method for estimation of the circulating blood volume

    DEFF Research Database (Denmark)

    Christensen, P; Eriksen, B; Henneberg, S W

    1993-01-01

    The present study is a theoretical and experimental evaluation of a modification of the carbon monoxide method for estimation of the circulating blood volume (CBV) with respect to the precision of the method. The CBV was determined from measurements of the CO-saturation of hemoglobin before...... ventilation with the CO gas mixture. The amount of CO administered during each determination of CBV resulted in an increase in the CO saturation of hemoglobin of 2.1%-3.9%. A theoretical noise propagation analysis was performed by means of the Monte Carlo method. The analysis showed that a CO dose...... patients. The coefficients of variation were 6.2% and 4.7% in healthy and diseased subjects, respectively. Furthermore, the day-to-day variation of the method with respect to the total amount of circulating hemoglobin (nHb) and CBV was determined from duplicate estimates separated by 24-48 h. In conclusion...

  2. Reference values for total blood volume and cardiac output in humans

    Energy Technology Data Exchange (ETDEWEB)

    Williams, L.R. [Indiana Univ., South Bend, IN (United States). Division of Liberal Arts and Sciences

    1994-09-01

    Much research has been devoted to measurement of total blood volume (TBV) and cardiac output (CO) in humans but not enough effort has been devoted to collection and reduction of results for the purpose of deriving typical or {open_quotes}reference{close_quotes} values. Identification of normal values for TBV and CO is needed not only for clinical evaluations but also for the development of biokinetic models for ultra-short-lived radionuclides used in nuclear medicine (Leggett and Williams 1989). The purpose of this report is to offer reference values for TBV and CO, along with estimates of the associated uncertainties that arise from intra- and inter-subject variation, errors in measurement techniques, and other sources. Reference values are derived for basal supine CO and TBV in reference adult humans, and differences associated with age, sex, body size, body position, exercise, and other circumstances are discussed.

  3. Role of cerebral blood volume changes in brain specific-gravity measurements

    International Nuclear Information System (INIS)

    Picozzi, P.; Todd, N.V.; Crockard, A.H.

    1985-01-01

    Cerebral blood volume (CBV) was calculated in gerbils from specific-gravity (SG) changes between normal and saline-perfused brains. Furthermore, changes in CBV were investigated during ischemia using carbon-14-labeled dextran (MW 70,000) as an intravascular marker. Both data were used to evaluate the possible error due to a change in CBV on the measurement of ischemic brain edema by the SG method. The methodological error found was 0.0004 for a 100% CBV change. This error is insignificant, being less than the standard deviation in the SG measured for the gerbil cortex. Thus, CBV changes are not responsible for the SG variations observed during the first phase of ischemia. These variations are better explained as an increase of brain water content during ischemia

  4. Phthalate SHEDS-HT runs

    Data.gov (United States)

    U.S. Environmental Protection Agency — Inputs and outputs for SHEDS-HT runs of DiNP, DEHP, DBP. This dataset is associated with the following publication: Moreau, M., J. Leonard, K. Phillips, J. Campbell,...

  5. Accurate measurement of volume and shape of resting and activated blood platelets from light scattering.

    Science.gov (United States)

    Moskalensky, Alexander E; Yurkin, Maxim A; Konokhova, Anastasiya I; Strokotov, Dmitry I; Nekrasov, Vyacheslav M; Chernyshev, Andrei V; Tsvetovskaya, Galina A; Chikova, Elena D; Maltsev, Valeri P

    2013-01-01

    We introduce a novel approach for determination of volume and shape of individual blood platelets modeled as an oblate spheroid from angle-resolved light scattering with flow-cytometric technique. The light-scattering profiles (LSPs) of individual platelets were measured with the scanning flow cytometer and the platelet characteristics were determined from the solution of the inverse light-scattering problem using the precomputed database of theoretical LSPs. We revealed a phenomenon of parameter compensation, which is partly explained in the framework of anomalous diffraction approximation. To overcome this problem, additional a priori information on the platelet refractive index was used. It allowed us to determine the size of each platelet with subdiffraction precision and independent of the particular value of the platelet aspect ratio. The shape (spheroidal aspect ratio) distributions of platelets showed substantial differences between native and activated by 10 μM adenosine diphosphate samples. We expect that the new approach may find use in hematological analyzers for accurate measurement of platelet volume distribution and for determination of the platelet activation efficiency.

  6. Effect of PEEP, blood volume, and inspiratory hold maneuvers on venous return.

    Science.gov (United States)

    Berger, David; Moller, Per W; Weber, Alberto; Bloch, Andreas; Bloechlinger, Stefan; Haenggi, Matthias; Sondergaard, Soren; Jakob, Stephan M; Magder, Sheldon; Takala, Jukka

    2016-09-01

    According to Guyton's model of circulation, mean systemic filling pressure (MSFP), right atrial pressure (RAP), and resistance to venous return (RVR) determine venous return. MSFP has been estimated from inspiratory hold-induced changes in RAP and blood flow. We studied the effect of positive end-expiratory pressure (PEEP) and blood volume on venous return and MSFP in pigs. MSFP was measured by balloon occlusion of the right atrium (MSFPRAO), and the MSFP obtained via extrapolation of pressure-flow relationships with airway occlusion (MSFPinsp_hold) was extrapolated from RAP/pulmonary artery flow (QPA) relationships during inspiratory holds at PEEP 5 and 10 cmH2O, after bleeding, and in hypervolemia. MSFPRAO increased with PEEP [PEEP 5, 12.9 (SD 2.5) mmHg; PEEP 10, 14.0 (SD 2.6) mmHg, P = 0.002] without change in QPA [2.75 (SD 0.43) vs. 2.56 (SD 0.45) l/min, P = 0.094]. MSFPRAO decreased after bleeding and increased in hypervolemia [10.8 (SD 2.2) and 16.4 (SD 3.0) mmHg, respectively, P waterfall. Copyright © 2016 the American Physiological Society.

  7. Cerebral blood flow in temporal lobe epilepsy: a partial volume correction study

    International Nuclear Information System (INIS)

    Giovacchini, Giampiero; Bonwetsch, Robert; Theodore, William H.; Herscovitch, Peter; Carson, Richard E.

    2007-01-01

    Previous studies in temporal lobe epilepsy (TLE) have shown that, owing to brain atrophy, positron emission tomography (PET) can overestimate deficits in measures of cerebral function such as glucose metabolism (CMR glu ) and neuroreceptor binding. The magnitude of this effect on cerebral blood flow (CBF) is unexplored. The aim of this study was to assess CBF deficits in TLE before and after magnetic resonance imaging-based partial volume correction (PVC). Absolute values of CBF for 21 TLE patients and nine controls were computed before and after PVC. In TLE patients, quantitative CMR glu measurements also were obtained. Before PVC, regional values of CBF were significantly (p glu in middle and inferior temporal cortex, fusiform gyrus and hippocampus both before and after PVC. A significant positive relationship between disease duration and AIs for CMR glu , but not CBF, was detected in hippocampus and amygdala, before but not after PVC. PVC should be used for PET CBF measurements in patients with TLE. Reduced blood flow, in contrast to glucose metabolism, is mainly due to structural changes. (orig.)

  8. Functional Response of Tumor Vasculature to PaCO2: Determination of Total and Microvascular Blood Volume by MRI

    Directory of Open Access Journals (Sweden)

    Scott D. Packard

    2003-07-01

    Full Text Available In order to identify differences in functional activity, we compared the reactivity of glioma vasculature and the native cerebral vasculature to both dilate and constrict in response to altered PaCO2. Gliomas were generated by unilateral implantation of U87MGdEGFR human glioma tumor cells into the striatum of adult female athymic rats. Relative changes in total and microvascular cerebral blood volume were determined by steady state contrast agent-enhanced magnetic resonance imaging for transitions from normocarbia to hypercarbia and hypocarbia. Although hypercarbia induced a significant increase in both total and microvascular blood volume in normal brain and glioma, reactivity of glioma vasculature was significantly blunted in comparison to normal striatum; glioma total CBV increased by 0.6±0.1%/mm Hg CO2 whereas normal striatum increased by 1.5±0.2%/mm Hg CO2, (P < .0001, group t-test. Reactivity of microvascular blood volume was also significantly blunted. In contrast, hypocarbia decreased both total and microvascular blood volumes more in glioma than in normal striatum. These results indicate that cerebral blood vessels derived by tumor-directed angiogenesis do retain reactivity to CO2. Furthermore, reduced reactivity of tumor vessels to a single physiological perturbation, such as hypercarbia, should not be construed as a generalized reduction of functional activity of the tumor vascular bed.

  9. Determination of the volume of circulating blood by means of in vivo labelled red blood cells with 99mTc pertechnetate and use of a Bulgarian kit

    International Nuclear Information System (INIS)

    Kostadinova, I.; Shejretova, E.; Pencheva, V.; Udvareva, N.

    1988-01-01

    A method was proposed for determination of the circulating blood volume (CBV) by means of in vivo labelled red blood cells, which was compared to the routine method with 51 Cr-sodium chromate. To the patients concecutively was given 1 g of potassium perchlorate (for blocking of the organs, which actively absorbed the perchnetate ion) and 500 mkg of tin pyrophosphate (Bulgarian kit) with subsequent labelling of the red blood cells with 99m Tc-pertechnate (1,8 - 3,7 MBq). The volume of the red blood cells, and hence also CBV, was measured with the use of a modified by the authors formula, in which correction for the individual effectiveness of the cell labelling was done. In comparison with the standard method for in vitro labelling of the red blood cells with 51 Cr sodium chromate, the method proposed gave an insignificant difference of 4,16%, but when compared to the commercial tin pyrophosphate (of the firm Mallinckrot - Holland), the Bulgarian kit displayed equivalent qualities. It was concluded that the method has a high accuracy and was easy for execution, cause a low radiation burden of the patient and is suitable for application in nuclear cardiology and radionuclide angiography

  10. Dynamic Contrast-Enhanced Computed Tomography-Derived Blood Volume and Blood Flow Correlate With Patient Outcome in Metastatic Renal Cell Carcinoma

    DEFF Research Database (Denmark)

    Mains, Jill Rachel; Donskov, Frede; Pedersen, Erik Morre

    2017-01-01

    = 7). Using a prototype software program (Advanced Perfusion and Permeability Application, Philips Healthcare, Best, the Netherlands), blood volume (BV), blood flow (BF), and permeability surface area product (PS) were calculated for each tumor at baseline, week 5, and week 10. These parameters......OBJECTIVES: The aim was to explore the potential for using dynamic contrast-enhanced computed tomography as a noninvasive functional imaging biomarker before and during the early treatment of metastatic renal cell carcinoma (mRCC). MATERIALS AND METHODS: Dynamic contrast-enhanced computed...

  11. Reduced left ventricular filling following blood volume extraction does not result in compensatory augmentation of cardiac mechanics.

    Science.gov (United States)

    Lord, Rachel; MacLeod, David; George, Keith; Oxborough, David; Shave, Rob; Stembridge, Mike

    2018-04-01

    What is the central question of this study? A reduction in left ventricular (LV) filling, and concomitant increase in heart rate, augments LV mechanics to maintain stroke volume (SV); however, the impact of reduced LV filling in isolation on SV and LV mechanics is currently unknown. What is the main finding and its importance? An isolated decrease in LV filling did not provoke a compensatory increase in mechanics to maintain SV; in contrast, LV mechanics and SV were reduced. These data indicate that when LV filling is reduced without changes in heart rate, LV mechanics do not compensate to maintain SV. An acute non-invasive reduction in preload has been shown to augment cardiac mechanics to maintain stroke volume and cardiac output. Such interventions induce concomitant changes in heart rate, whereas blood volume extraction reduces preload without changes in heart rate. Therefore, the purpose of this study was to determine whether a preload reduction in isolation resulted in augmented stroke volume achieved via enhanced cardiac mechanics. Nine healthy volunteers (four female, age 29 ± 11 years) underwent echocardiography for the assessment of left ventricular (LV) volumes and mechanics in a supine position at baseline and end extraction after the controlled removal of 25% of total blood volume (1062 ± 342 ml). Arterial blood pressure was monitored continuously by a pressure transducer attached to an indwelling radial artery catheter. Heart rate and total peripheral resistance were unchanged from baseline to end extraction, but systolic blood pressure was reduced (from 148 to 127 mmHg). From baseline to end extraction there were significant reductions in left ventricular end-diastolic volume (from 89 to 71 ml) and stroke volume (from 56 to 37 ml); however, there was no change in LV twist, basal or apical rotation. In contrast, LV longitudinal strain (from -20 to -17%) and basal circumferential strain (from -22 to -19%) were significantly reduced from

  12. A study on the pulmonary mean transit time and the pulmonary blood volume by RI-cardiogram

    International Nuclear Information System (INIS)

    Ushio, Norio

    1987-01-01

    The pulmonary mean transit time and the pulmonary blood volume in cases of cardio-pulmonary disease were measured using Giuntini's method which is considered the most appropriate among radiocardiographic methods. The errors in this method were confirmed to be almost negligible. The results obtained were as follows: 1) The pulmonary mean transit time was related to the systemic mean transit time and markedly prolonged in left heart failure. On the other hand, it was markedly shortened in some cases of chronic pulmonary disease, particularly pulmonary emphysema. 2) The pulmonary blood volume tended to increase in left heart disorders and mitral valve disease and tended to decrease in the chronic pulmonary disease. The decrease was conspicuous particularly in some cases of pulmonary emphysema. 3) A structural change of the pulmonary vascular system in the chronic pulmonary disease appeared to bring about shortening of the pulmonary mean transit time and a decrease in the pulmonary blood volume. The pathophysiology of cardio-pulmonary disease can be more clarified by the RI-cardiogram used in this study, in which the pulmonary mean transit time and the pulmonary blood volume are used as the indicator. (author)

  13. Anuran amphibians as comparative models for understanding extreme dehydration tolerance: a negative feedback lymphatic mechanism for blood volume regulation.

    Science.gov (United States)

    Hillman, Stanley S

    2018-06-06

    Anurans are the most terrestrial order of amphibians. Couple the high driving forces for evaporative loss in terrestrial environments and their low resistance to evaporation, dehydration is an inevitable stress on their water balance. Anurans have the greatest tolerances for dehydration of any vertebrate group, some species can tolerate evaporative losses up to 45% of their standard body mass. Anurans have remarkable capacities to regulate blood volume with hemorrhage and dehydration compared to mammals. Stabilization of blood volume is central to extending dehydration tolerance, since it avoids both the hypovolemic and hyperviscosity stresses on cardiac output and its consequential effects on aerobic capacity. Anurans, in contrast to mammals, seem incapable of generating a sufficient pressure difference, either oncotically or via interstitial compliance, to move fluid from the interstitium into the capillaries. Couple this inability to generate a sufficient pressure difference for transvascular uptake to a circulatory system with high filtration coefficients and a high rate of plasma turnover is the consequence. The novel lymphatic system of anurans is critical to a remarkable capacity for blood volume regulation. This review summarizes what is known about the anatomical and physiological specializations which are involved in explaining differential blood volume regulation and dehydration tolerance involving a true centrally mediated negative feedback of lymphatic function involving baroreceptors as sensors and lymph hearts, AVT, pulmonary ventilation and specialized skeletal muscles as effectors.

  14. The Effects of TM on Concurrent Heart Rate, Peripheral Blood Pulse Volume, and the Alpha Wave Frequency.

    Science.gov (United States)

    Lukas, Jerome S.

    Through observation of 26 subjects over a 3 month period, this research project measured the effects of transcendental meditation (TM) on concurrent heart rate, peripheral blood pulse volume, and the alpha wave frequency. The subjects were assigned randomly to three groups. One group practiced TM as prescribed by the International Meditation…

  15. Relationship between haemoglobin concentration and packed cell volume in cattle blood samples

    Directory of Open Access Journals (Sweden)

    Paa-Kobina Turkson

    2015-02-01

    Full Text Available A convention that has been adopted in medicine is to estimate haemoglobin (HB concentration as a third of packed cell volume (PCV or vice versa. The present research set out to determine whether a proportional relationship exists between PCV and Hb concentration in cattle blood samples, and to assess the validity of the convention of estimating Hb concentration as a third of PCV. A total of 440 cattle in Ghana from four breeds (Ndama, 110; West African Short Horn, 110; Zebu, 110 and Sanga, 110 were bled for haematological analysis, specifically packed cell volume, using the microhaematocrit technique and haemoglobin concentration using the cyanmethaemoglobin method. Means, standard deviations, standard errors of mean and 95% confidence intervals were calculated. Trendline analyses generated linear regression equations from scatterplots. For all the cattle, a significant and consistent relationship (r = 0.74 was found between Hb concentration and PCV (%. This was expressed as Hb concentration (g/dL = 0.28 PCV + 3.11. When the Hb concentration was estimated by calculating it as a third of PCV, the relationship was expressed in linear regression as Hb concentration (g/dL = 0.83 calculated Hb + 3.11. The difference in the means of determined (12.2 g/dL and calculated (10.9 g/dL Hb concentrations for all cattle was significant (p < 0.001, whereas the difference in the means of determined Hb and corrected calculated Hb was not significant. In conclusion, a simplified relationship of Hb (g/dL = (0.3 PCV + 3 may provide a better estimate of Hb concentration from the PCV of cattle.

  16. Cerebral blood flow in temporal lobe epilepsy: a partial volume correction study

    Energy Technology Data Exchange (ETDEWEB)

    Giovacchini, Giampiero [University Milano-Bicocca, Milan (Italy); Bonwetsch, Robert; Theodore, William H. [National Institute of Neurological Diseases and Strokes, Clinical Epilepsy Section, Bethesda, MD (United States); Herscovitch, Peter [National Institutes of Health, PET Department, Clinical Center, Bethesda, MD (United States); Carson, Richard E. [Yale PET Center, New Haven, CT (United States)

    2007-12-15

    Previous studies in temporal lobe epilepsy (TLE) have shown that, owing to brain atrophy, positron emission tomography (PET) can overestimate deficits in measures of cerebral function such as glucose metabolism (CMR{sub glu}) and neuroreceptor binding. The magnitude of this effect on cerebral blood flow (CBF) is unexplored. The aim of this study was to assess CBF deficits in TLE before and after magnetic resonance imaging-based partial volume correction (PVC). Absolute values of CBF for 21 TLE patients and nine controls were computed before and after PVC. In TLE patients, quantitative CMR{sub glu} measurements also were obtained. Before PVC, regional values of CBF were significantly (p<0.05) lower in TLE patients than in controls in all regions, except the fusiform gyrus contralateral to the epileptic focus. After PVC, statistical significance was maintained in only four regions: ipsilateral inferior temporal cortex, bilateral insula and contralateral amygdala. There was no significant difference between patients and controls in CBF asymmetry indices (AIs) in any region before or after PVC. In TLE patients, AIs for CBF were significantly smaller than for CMR{sub glu} in middle and inferior temporal cortex, fusiform gyrus and hippocampus both before and after PVC. A significant positive relationship between disease duration and AIs for CMR{sub glu}, but not CBF, was detected in hippocampus and amygdala, before but not after PVC. PVC should be used for PET CBF measurements in patients with TLE. Reduced blood flow, in contrast to glucose metabolism, is mainly due to structural changes. (orig.)

  17. ECG-gated blood pool tomography in the determination of left ventricular volume, ejection fraction, and wall motion

    International Nuclear Information System (INIS)

    Underwood, S.R.; Ell, P.J.; Jarritt, P.H.; Emanuel, R.W.; Swanton, R.H.

    1984-01-01

    ECG-gated blood pool tomography promises to provide a ''gold standard'' for noninvasive measurement of left ventricular volume, ejection fraction, and wall motion. This study compares these measurements with those from planar radionuclide imaging and contrast ventriculography. End diastolic and end systolic blood pool images were acquired tomographically using an IGE400A rotating gamma camera and Star computer, and slices were reconstructed orthogonal to the long axis of the heart. Left ventricular volume was determined by summing the areas of the slices, and wall motion was determined by comparison of end diastolic and end systolic contours. In phantom experiments this provided an accurate measurement of volume (r=0.98). In 32 subjects who were either normal or who had coronary artery disease left ventricular volume (r=0.83) and ejection fraction (r=0.89) correlated well with those using a counts based planar technique. In 16 of 18 subjects who underwent right anterior oblique X-ray contrast ventriculography, tomographic wall motion agreed for anterior, apical, and inferior walls, but abnormal septal motion which was not apparent by contrast ventriculography, was seen in 12 subjects tomographically. All 12 had disease of the left anterior descending coronary artery and might have been expected to have abnormal septal motion. ECG-gated blood pool tomography can thus determine left ventricular volume and ejection fraction accurately, and provides a global description of wall motion in a way that is not possible from any single planar image

  18. Effects of radiation on the skin blood volume pulse in humans

    Energy Technology Data Exchange (ETDEWEB)

    Zanelli, G D [Mount Vernon Hospital, Northwood (UK)

    1977-01-01

    Measurements have been made of the changes in skin blood volume pulse (BVP) in the irradiated skin of three patients (two female, one male) during and up to 250 days after radiotherapy for malignant disease. The instrumentation comprised a modified commercial finger photo-plethysmograph probe with associated electronics, and a survey of the literature revealed that the consensus of opinion seems to be that the recorded pulsations arise from small 'muscular' arteries and arterioles in the 40 to 300 ..mu..m size range. The results show that, as expected, normal, untreated skin shows sizeable variations in BVP. The BVP of irradiated skin became significantly greater than that of normal skin when a dose of 1000 to 1500 rad has been accumulated. The maximum amplitude of the BVP of the irradiated skin seemed to correlate well with the overall severity of the erythema, but increases in BVP preceded erythema flare-ups. In two patients, elevated BVP were recorded for irradiated areas even when most visual signs of erythema had disappeared. Mild cooling of irradiated and non-irradiated skin had differing effects in the BVP. The measurement of the BVP of irradiated skin is a simple, reliable and completely atraumatic method for investigating vascular damage to superficial tissues in humans.

  19. Cannula Tip With Integrated Volume Sensor for Rotary Blood Pump Control: Early-Stage Development.

    Science.gov (United States)

    Cysyk, Joshua; Newswanger, Ray; Popjes, Eric; Pae, Walter; Jhun, Choon-Sik; Izer, Jenelle; Weiss, William; Rosenberg, Gerson

    2018-05-10

    The lack of direct measurement of left ventricular unloading is a significant impediment to the development of an automatic speed control system for continuous-flow left ventricular assist devices (cf-LVADs). We have developed an inlet cannula tip for cf-LVADs with integrated electrodes for volume sensing based on conductance. Four platinum-iridium ring electrodes were installed into grooves on a cannula body constructed from polyetheretherketone (PEEK). A sinusoidal current excitation waveform (250 μA pk-pk, 50 kHz) was applied across one pair of electrodes, and the conductance-dependent voltage was sensed across the second pair of electrodes. The conductance catheter was tested in an acute ovine model (n = 3) in conjunction with the HeartMate II rotary blood pump to provide circulatory support and unload the ventricle. Echocardiography was used to measure ventricular size during pump support for verification for the conductance measurements. The conductance measurements correlated linearly with the echocardiography dimension measurements more than the full range of pump support from minimum support to suction. This cannula tip will enable the development of automatic control systems to optimize pump support based on a real-time measurement of ventricular size.

  20. MRI assessment of cerebral blood volume in patients with brain infarcts

    International Nuclear Information System (INIS)

    Wu, R.H.; Bruening, R.; Berchtenbreiter, C.; Weber, J.; Peller, M.; Penzkofer, H.; Reiser, M.; Steiger, H.J.

    1998-01-01

    MRI perfusion studies have focussed mainly on acute ischaemia and characterisation in ischaemia. Our purpose was to analyse regional brain haemodynamic information in acute, subacute, and chronic ischaemia. We performed 16 examinations of 11 patients on a 1.5 T MR images. Conventional and dynamic contrast-enhanced imaging were employed in all examinations. For the dynamic susceptibility sequences, a bolus (0.2 mmol/kg) of gadopentetate dimeglumine was injected. Reconstructed regional relative cerebral blood volume (rCBV) maps, bolus maps, and conventional images were analysed by consensus reading. In all examinations decreases in rCBV were observed in the lesions. The distribution of regional rCBV in lesions was heterogeneous. The rCBV of the periphery of the lesions was higher than that at their center. There was a correlation between the time since onset and abnormalities on the rCBV map and T2-weighted images (T2WI). In the early stage of acute stroke, the abnormalities tended to be larger on the rCBV than on T2WI. Many patterns of bolus passage were observed in ischaemic regions. rCBV maps provide additional haemodynamic information in patients with brain infarcts. (orig.)

  1. Remote spectral measurements of the blood volume pulse with applications for imaging photoplethysmography

    Science.gov (United States)

    Blackford, Ethan B.; Estepp, Justin R.; McDuff, Daniel J.

    2018-02-01

    Imaging photoplethysmography uses camera image sensors to measure variations in light absorption related to the delivery of the blood volume pulse to peripheral tissues. The characteristics of the measured BVP waveform depends on the spectral absorption of various tissue components including melanin, hemoglobin, water, and yellow pigments. Signal quality and artifact rejection can be enhanced by taking into account the spectral properties of the BVP waveform and surrounding tissue. The current literature regarding the spectral relationships of remote PPG is limited. To supplement this fundamental data, we present an analysis of remotely-measured, visible and near-infrared spectroscopy to better understand the spectral signature of remotely measured BVP signals. To do so, spectra were measured from the right cheek of 25, stationary participants whose heads were stabilized by a chinrest. A collimating lens was used to collect reflected light from a region of 3 cm in diameter. The spectrometer provided 3 nm resolution measurements from 500-1000 nm. Measurements were acquired at a rate of 50 complete spectra per second for a period of five minutes. Reference physiology, including electrocardiography was simultaneously and synchronously acquired. The spectral data were analyzed to determine the relationship between light wavelength and the resulting remote-BVP signal-to-noise ratio and to identify those bands best suited for pulse rate measurement. To our knowledge this is the most comprehensive dataset of remotely-measured spectral iPPG data. In due course, we plan to release this dataset for research purposes.

  2. Blood volume of nonsplenectomized and splenectomized cats before and after acute hemorrhage

    International Nuclear Information System (INIS)

    Breznock, E.M.; Strack, D.

    1982-01-01

    Blood volume (BV) was determined in awake, nonsplenectomized (NSPX) and splenectomized (SPX) cats before and after hemorrhage (6 ml/kg). Each NSPX cat had a determined BV at least 10 ml/kg greater than the same cat after splenectomy. The mean BV of SPX cats was 43.4 +/- 8.94. ml kg (4.3% of body weight). The calculated RBC masses of NSPX and SPX cats were 17.0 +/- 4.07 and 12.2 +/- 1.12 ml/kg, respectively. Each NSPX cat had apparent RBC masses of 5 ml/kg greater than that of the same cat after splenectomy was done. At 1 hour after a hemorrhage, the BV and RBC masses determined in SPX cats were 46.7 +/- 12.1 and 9.7 +/- 1.90 ml/kg, respectively. Extravascular-to-intravascular fluid flux (calculated from RBC masses and plasma protein dilution) was approximately 0.80% of body weight. The indirect method with 51 Cr-labeled RBC for BV determination was accurate and precise in awake, SPX cats; in awake, NSPX cats, the 51 Cr-labeled RBC dilution method was precise, but not accurate. The spleen in the cat resulted in marked overestimations of BV and RBC masses

  3. Cerebral blood volume imaging by flat detector computed tomography in comparison to conventional multislice perfusion CT

    International Nuclear Information System (INIS)

    Struffert, Tobias; Kloska, Stephan; Engelhorn, Tobias; Doerfler, Arnd; Deuerling-Zheng, Yu; Boese, Jan; Zellerhoff, Michael; Schwab, Stefan

    2011-01-01

    We tested the hypothesis that Flat Detector computed tomography (FD-CT) with intravenous contrast medium would allow the calculation of whole brain cerebral blood volume (CBV) mapping (FD-CBV) and would correlate with multislice Perfusion CT (PCT). Twenty five patients were investigated with FD-CBV and PCT. Correlation of the CBV maps of both techniques was carried out with measurements from six anatomical regions from both sides of the brain. Mean values of each region and the correlation coefficient were calculated. Bland-Altman analysis was performed to compare the two different imaging techniques. The image and data quality of both PCT and FD-CBV were suitable for evaluation in all patients. The mean CBV values of FD-CBV and PCT showed only minimal differences with overlapping standard deviation. The correlation coefficient was 0.79 (p < 0.01). Bland-Altman analysis showed a mean difference of -0.077 ± 0.48 ml/100 g between FD-CBV and PCT CBV measurements, indicating that FD-CBV values were only slightly lower than those of PCT. CBV mapping with intravenous contrast medium using Flat Detector CT compared favourably with multislice PCT. The ability to assess cerebral perfusion within the angiographic suite may improve the management of ischaemic stroke and evaluation of the efficacy of dedicated therapies. (orig.)

  4. Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging.

    Science.gov (United States)

    Rempp, K A; Brix, G; Wenz, F; Becker, C R; Gückel, F; Lorenz, W J

    1994-12-01

    Quantification of regional cerebral blood flow (rCBF) and volume (rCBV) with dynamic magnetic resonance (MR) imaging. After bolus administration of a paramagnetic contrast medium, rapid T2*-weighted gradient-echo images of two sections were acquired for the simultaneous creation of concentration-time curves in the brain-feeding arteries and in brain tissue. Absolute rCBF and rCBV values were determined for gray and white brain matter in 12 subjects with use of principles of the indicator dilution theory. The mean rCBF value in gray matter was 69.7 mL/min +/- 29.7 per 100 g tissue and in white matter, 33.6 mL/min +/- 11.5 per 100 g tissue; the average rCBV was 8.0 mL +/- 3.1 per 100 g tissue and 4.2 mL +/- 1.0 per 100 g tissue, respectively. An age-related decrease in rCBF and rCBV for gray and white matter was observed. Preliminary data demonstrate that the proposed technique allows the quantification of rCBF and rCBV. Although the results are in good agreement with data from positron emission tomography studies, further evaluation is needed to establish the validity of method.

  5. Echo-planar MR cerebral blood volume mapping of glomas. Clinical utility

    International Nuclear Information System (INIS)

    Aronen, H.J.; Univ. Central Hospital, Helsinki; Glass, J.; Pardo, F.S.; Belliveau, J.W.; Gruber, M.L.; Buchbinder, B.R.; Gazit, I.E.; Linggood, R.M.; Fischman, A.J.; Rosen, F.S.; Hochberg, F.H.

    1995-01-01

    Neovascularization is a common phenomenon in gliomas. MR imaging cerebral blood volume (CBV) mapping utilizes ultrafast echo-planar imaging and simultaneous use of gadolinium-based contrast material. To determine the utility of MR CBV mapping in the clinical evaluation of gliomas, we followed 15 patients with serial studies. This technique provided functional information that was not evident with conventional CT or MR imaging. Low-grade tumors demonstrated homogeneously low CBV, while high-grade tumors often showed areas of both high and low CBV. The maximum tumor CBV/white matter ratio was compared between low- (n=3) and high-grade gliomas (n=5) in patients without previous treatment and with histologic verification (n=8) and was significantly higher in high-grade gliomas (p<0.01), High CBV foci in nonenhancing tumor areas were present in 2 cases. The distinction between radiation necrosis and active tumor could be made correctly in 3 of 4 cases. The information provided by MR CBV mapping has the potential to be an adjunct in the clinical care of glioma patients. (orig.)

  6. Comparison of pathogen DNA isolation methods from large volumes of whole blood to improve molecular diagnosis of bloodstream infections.

    Directory of Open Access Journals (Sweden)

    Anne J M Loonen

    Full Text Available For patients suffering from bloodstream infections (BSI molecular diagnostics from whole blood holds promise to provide fast and adequate treatment. However, this approach is hampered by the need of large blood volumes. Three methods for pathogen DNA isolation from whole blood were compared, i.e. an enzymatic method (MolYsis, 1-5 ml, the novel non-enzymatic procedure (Polaris, 1-5 ml, and a method that does not entail removal of human DNA (Triton-Tris-EDTA EasyMAG, 200 µl. These methods were evaluated by processing blood spiked with 0-1000 CFU/ml of Staphylococcus aureus, Pseudomonas aeruginosa and Candida albicans. Downstream detection was performed with real-time PCR assays. Polaris and MolYsis processing followed by real-time PCRs enabled pathogen detection at clinically relevant concentrations of 1-10 CFU/ml blood. By increasing sample volumes, concurrent lower cycle threshold (Ct values were obtained at clinically relevant pathogen concentrations, demonstrating the benefit of using larger blood volumes. A 100% detection rate at a concentration of 10 CFU/ml for all tested pathogens was obtained with the Polaris enrichment, whereas comparatively lower detection rates were measured for MolYsis (50-67% and EasyMAG (58-79%. For the samples with a concentration of 1 CFU/ml Polaris resulted in most optimal detection rates of 70-75% (MolYsis 17-50% and TTE-EasyMAG 20-36%. The Polaris method was more reproducible, less labour intensive, and faster (45 minutes (including Qiagen DNA extraction vs. 2 hours (MolYsis. In conclusion, Polaris and MolYsis enrichment followed by DNA isolation and real-time PCR enables reliable and sensitive detection of bacteria and fungi from 5 ml blood. With Polaris results are available within 3 hours, showing potential for improved BSI diagnostics.

  7. Prediction of Packed Cell Volume after Whole Blood Transfusion in Small Ruminants and South American Camelids: 80 Cases (2006–2016)

    OpenAIRE

    Luethy, D.; Stefanovski, D.; Salber, R.; Sweeney, R.W.

    2017-01-01

    Background Calculation of desired whole blood transfusion volume relies on an estimate of an animal's circulating blood volume, generally accepted to be 0.08 L/kg or 8% of the animal's body weight in kilograms. Objective To use packed cell volume before and after whole blood transfusion to evaluate the accuracy of a commonly used equation to predict packed cell volume after transfusion in small ruminants and South American camelids; to determine the nature and frequency of adverse transfusion...

  8. A Means for the Scintigraphic Imaging of Regional Brain Dynamics. Regional Cerebral Blood Flow and Regional Cerebral Blood Volume

    Energy Technology Data Exchange (ETDEWEB)

    Potchen, E. J.; Bentley, R.; Gerth, W.; Hill, R. L.; Davis, D. O. [Washington University School Of Medicine, St. Louis, MO (United States)

    1969-05-15

    The use of freely diffusable inert radioactive gas as a washout indicator to measure regional cerebral blood flow has become a standardized kinetic procedure in many laboratories. Recent investigations with this technique have led us to conclude that we can reliably distinguish regional flow with perfusion against regional flow without perfusion from the early portion of the curve. Based on a detailed study of the early curve kinetics in patients with and without cerebral vascular disease we have defined the sampling duration necessary for application of the Anger gamma camera imaging process to regional changes in cerebral radioactivity. Using a standard camera and a small computer, a procedure has been developed and based upon entire field to determine the time of maximum height followed by analysis of the data in a matrix. This will permit a contour plot presentation of calculated regional cerebral blood flow in millilitres per 100 grams perfused brain per minute. In addition, we propose to augment this data by the display of regional non-perfusion blood flow versus regional cerebral flow with perfusion. Preliminary investigation on sampling duration, and Compton scattering were prerequisite to clinical scintigraphy of regional cerebral blood flow. In addition, the method of interface for the conventional Anger gamma camera to digital computers used in this procedure are discussed. Applications to further assess regional cerebral dynamics by scintigraphy are presented. (author)

  9. Analysis of decrease in lung perfusion blood volume with occlusive and non-occlusive pulmonary embolisms

    International Nuclear Information System (INIS)

    Ikeda, Yohei; Yoshimura, Norihiko; Hori, Yoshiro; Horii, Yosuke; Ishikawa, Hiroyuki; Yamazaki, Motohiko; Noto, Yoshiyuki; Aoyama, Hidefumi

    2014-01-01

    Highlights: • The proportion of preserved PE lesions in the non-occlusive group was 76.7% (33/43). • HUs of the iodine map were significantly higher in the non-occlusive group than in the occlusive group. • There was no significant difference in HUs between the non-occlusive and corresponding normal group. - Abstract: Purpose: The aim of this study was to determine if lung perfusion blood volume (lung PBV) with non-occlusive pulmonary embolism (PE) differs quantitatively and visually from that with occlusive PE and to investigate if lung PBV with non-occlusive PE remains the same as that without PE. Materials and methods: Totally, 108 patients suspected of having acute PE underwent pulmonary dual-energy computed tomography angiography (DECTA) between April 2011 and January 2012. Presence of PE on DECTA was evaluated by one radiologist. Two radiologists visually evaluated the PE distribution (segmental or subsegmental) and its nature (occlusive or non-occlusive) on DECTA and classified perfusion in lung PBV as “decreased,” “slightly decreased,” and “preserved”. Two radiologists used a lung PBV application to set a region of interest (ROI) in the center of the lesion and measured HU values of an iodine map. In the same slice as the ROI of the lesion and close to the lesion, another ROI was set in the normal perfusion area without PE, and HUs were measured. The proportion of lesions was compared between the occlusive and non-occlusive groups. HUs were compared among the occlusive, non-occlusive, and corresponding normal groups. Results: Twenty-five patients had 80 segmental or subsegmental lesions. There were 37 and 43 lesions in the occlusive and non-occlusive groups, respectively. The proportion of decreased lesions was 73.0% (27/37) in the occlusive group, while that of preserved lesions in the non-occlusive group was 76.7% (33/43). There was a significant difference in the proportion of lesions (P < 0.001) between the two groups. HUs of the

  10. Analysis of renal blood flow and renal volume in normal fetuses and in fetuses with a solitary functioning kidney.

    Science.gov (United States)

    Hindryckx, An; Raaijmakers, Anke; Levtchenko, Elena; Allegaert, Karel; De Catte, Luc

    2017-12-01

    To evaluate renal blood flow and renal volume for the prediction of postnatal renal function in fetuses with solitary functioning kidney (SFK). Seventy-four SFK fetuses (unilateral renal agenesis [12], multicystic dysplastic kidney [36], and severe renal dysplasia [26]) were compared with 58 healthy fetuses. Peak systolic velocity (PSV), pulsatility index (PI), and resistance index (RI) of the renal artery (RA) were measured; 2D and 3D (VOCAL) volumes were calculated. Renal length and glomerular filtration rate (GFR) were obtained in SFK children (2 years). Compared with the control group, the PSV RA was significantly lower in nonfunctioning kidneys and significantly higher in SFK. Volume measurements indicated a significantly larger volume of SFK compared with healthy kidneys. All but 4 children had GFR above 70 mL/min/1.73 m 2 , and compensatory hypertrophy was present in 69% at 2 years. PSV RA and SFK volume correlated with postnatal renal hypertrophy. No correlation between prenatal and postnatal SFK volume and GFR at 2 years was demonstrated. Low PSV RA might have a predictive value for diagnosing a nonfunctioning kidney in fetuses with a SFK. We demonstrated a higher PSV RA and larger renal volume in the SFK compared with healthy kidneys. © 2017 John Wiley & Sons, Ltd.

  11. Low Cerebral Blood Volume Identifies Poor Outcome in Stent Retriever Thrombectomy

    International Nuclear Information System (INIS)

    Protto, Sara; Pienimäki, Juha-Pekka; Seppänen, Janne; Numminen, Heikki; Sillanpää, Niko

    2017-01-01

    BackgroundMechanical thrombectomy (MT) is an efficient treatment of acute stroke caused by large-vessel occlusion. We evaluated the factors predicting poor clinical outcome (3-month modified Rankin Scale, mRS >2) although MT performed with modern stent retrievers.MethodsWe prospectively collected the clinical and imaging data of 105 consecutive anterior circulation stroke patients who underwent MT after multimodal CT imaging. Patients with occlusion of the internal carotid artery and/or middle cerebral artery up to the M2 segment were included. We recorded baseline clinical, procedural and imaging variables, technical outcome, 24-h imaging outcome and the clinical outcome. Differences between the groups were studied with appropriate statistical tests and binary logistic regression analysis.ResultsLow cerebral blood volume Alberta stroke program early CT score (CBV-ASPECTS) was associated with poor clinical outcome (median 7 vs. 9, p = 0.01). Lower collateral score (CS) significantly predicted poor outcome in regression modelling with CS = 0 increasing the odds of poor outcome 4.4-fold compared to CS = 3 (95% CI 1.27–15.5, p = 0.02). Lower CBV-ASPECTS significantly predicted poor clinical outcome among those with moderate or severe stroke (OR 0.82, 95% CI 0.68–1, p = 0.05) or poor collateral circulation (CS 0–1, OR 0.66, 95% CI 0.48–0.90, p = 0.009) but not among those with mild strokes or good collaterals.ConclusionsCBV-ASPECTS estimating infarct core is a significant predictor of poor clinical outcome among anterior circulation stroke patients treated with MT, especially in the setting of poor collateral circulation and/or moderate or severe stroke.

  12. Low Cerebral Blood Volume Identifies Poor Outcome in Stent Retriever Thrombectomy

    Energy Technology Data Exchange (ETDEWEB)

    Protto, Sara, E-mail: sara.protto@pshp.fi; Pienimäki, Juha-Pekka; Seppänen, Janne [Tampere University Hospital, Medical Imaging Center (Finland); Numminen, Heikki [Tampere University Hospital, Department of Neurology (Finland); Sillanpää, Niko [Tampere University Hospital, Medical Imaging Center (Finland)

    2017-04-15

    BackgroundMechanical thrombectomy (MT) is an efficient treatment of acute stroke caused by large-vessel occlusion. We evaluated the factors predicting poor clinical outcome (3-month modified Rankin Scale, mRS >2) although MT performed with modern stent retrievers.MethodsWe prospectively collected the clinical and imaging data of 105 consecutive anterior circulation stroke patients who underwent MT after multimodal CT imaging. Patients with occlusion of the internal carotid artery and/or middle cerebral artery up to the M2 segment were included. We recorded baseline clinical, procedural and imaging variables, technical outcome, 24-h imaging outcome and the clinical outcome. Differences between the groups were studied with appropriate statistical tests and binary logistic regression analysis.ResultsLow cerebral blood volume Alberta stroke program early CT score (CBV-ASPECTS) was associated with poor clinical outcome (median 7 vs. 9, p = 0.01). Lower collateral score (CS) significantly predicted poor outcome in regression modelling with CS = 0 increasing the odds of poor outcome 4.4-fold compared to CS = 3 (95% CI 1.27–15.5, p = 0.02). Lower CBV-ASPECTS significantly predicted poor clinical outcome among those with moderate or severe stroke (OR 0.82, 95% CI 0.68–1, p = 0.05) or poor collateral circulation (CS 0–1, OR 0.66, 95% CI 0.48–0.90, p = 0.009) but not among those with mild strokes or good collaterals.ConclusionsCBV-ASPECTS estimating infarct core is a significant predictor of poor clinical outcome among anterior circulation stroke patients treated with MT, especially in the setting of poor collateral circulation and/or moderate or severe stroke.

  13. Evaluation of regional cerebral blood flow and volume of rapidly exchangeable water in man by positron emission tomography

    International Nuclear Information System (INIS)

    Depresseux, J.C.; Cheslet, J.P.; Hodiaumont, J.

    1982-01-01

    The present investigation uses bolus inhalation of C 15 O 2 and sequential positron emission tomography of the brain in view to simultaneously evaluate regional cerebral blood flow and regional cerebral volume of rapidly exchangeable water in normal human subjects. Arguments allow to infer that the cerebral distribution volume of radiowater does vary with time during the initial period of invasion of tissue by the indicator. Implications of this variation on the validity of classical data procedures is discussed and an alternative original method is proposed [fr

  14. An intravenous isotope method for measuring regional cerebral blood flow (rCBF) and volume (rCBV)

    International Nuclear Information System (INIS)

    Kuikka, J.; Ahonen, A.; Koivula, A.; Kallanranta, T.; Laitinen, J.

    1977-01-01

    The regional cerebal blood flow (rCBF), initial slope index (ISI), transfer time (t - sub(h)) and volume (rCBV) were measured simultaneously in 43 hospital patients using a 133 Xe intravenous injection method and quantitative dynamic 99 Tcsup(m) brain scintigraphy. The measurements were made with a gamma camera and the data processing interfaced with a small digital computer. The mean values and standard deviations were obtained from 50 control hemispheres standardized to the age of 40 years. Good agreement was found between the blood flow values determined from the intra-arterial and intravenous injection techniques. (author)

  15. Irradiation of blood, blood compounds and cell culture in equipment of radiotherapy of clinical usage. Study about volume and ideal dose

    International Nuclear Information System (INIS)

    Fernandes, Marco Antonio Rodrigues; Pereira, Adelino Jose; Novaes, Paulo Eduardo Ribeiro dos Santos

    1996-01-01

    The irradiation of blood bags with the objective of minimizing the graft-versus-host disease in the proceedings of blood transfusion has been consolidated as an indispensable step in the advances of hematopoietic system diseases therapeutics. This practice performed in the great oncological treatment centers requires appropriate equipment (cell irradiators), that due to the high coast, is inaccessible to the majority of the services. The main objective of this work is the show the technique developed by the Radiological Physics Service of the Hospital A. C. Camargo Radiation Department, using the teletherapy equipment of clinical usage available at the Institution. The literature shows that a total dose of 2000 to 3500 c Gy must be administered to all target volume to get an ideal dose/volume relation that proportionates better therapeutic results, neutralizing the cells which are causative of post transfusion reactions of rejection, without prejudicing the other cells that are necessary to the maintenance and preservation of the transplanted person's hematopoietic system functions. With the technic developed for optimization of the irradiation. it is possible to conclude that the utilization of radiotherapy equipment of clinical usage for blood irradiation, substituting cells irradiators, is a good option, permitting safe transfusion of products irradiated with adequate dose. (author)

  16. Induced renal artery stenosis in rabbits: magnetic resonance imaging, angiography, and radionuclide determination of blood volume and blood flow

    International Nuclear Information System (INIS)

    Mitchell, D.G.; Tobin, M.; LeVeen, R.; Tomaczewski, J.; Alavi, A.; Staum, M.; Kundel, H.

    1988-01-01

    To investigate the ability of MRI to detect alterations due to renal ischemia, a rabbit renal artery stenosis (RAS) model was developed. Seven rabbits had RAS induced by surgically encircling the artery with a polyethylene band which had a lumen of 1 mm, 1 to 2 weeks prior to imaging. The stenosis was confirmed by angiography, and the rabbits were then imaged in a 1.4 T research MRI unit. T1 was calculated using four inversion recovery sequences with different inversion times. Renal blood flow, using 113 Sn-microspheres, and regional water content by drying were then measured. The average T1 of the inner medulla was shorter for the ischemia (1574 msec) than for the contralateral kidney (1849 msec), while no change ws noted in the cortex. Ischemic kidneys had less distinct outer medullary zones on IR images with TI = 600 msec than did contralateral or control kidneys. Blood flow to both the cortex and medulla were markedly reduced in ischemic kidneys compared with contralateral kidneys (119.5 vs. 391 ml/min/100 gm for cortex and 19.8 vs. 50.8 ml/min/100 gm for medulla). Renal water and blood content were less affected. Our rabbit model of renal artery stenosis with MRI, radionuclide, and angiographic correlation has the potential to increase our understanding of MR imaging of the rabbit kidney

  17. Positron emission tomography in cerebrovascular disease: The relationship between regional cerebral blood flow, blood volume and oxygen metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Herold, S.

    1985-03-01

    Positron emission tomography in cerebrovascular disease has demonstrated the importance of the relationship between regional cerebral blood flow and the cerebral metabolic activity. In acute stroke it has been found that within the first hours after the onset of symptoms cerebral blood flow in the affected area is more depressed than cerebral oxygen utilisation. This relative preservation of oxygen utilisation results from an increase in the oxygen extraction ratio far above its normal value. However, the oxygen extraction fraction subsequently falls in the following days indicating the transition from a situation of possibly reversible ischaemia to irreversible infarction. In patients with carotid occlusive disease an increase in the oxygen extraction ratio has been observed only in very few cases. It has been shown, however, that at an earlier stage the relationship between CBF and CBV (as CBF/CBV-ratio) provides a sensitive measure of diminished perfusion pressure which could be helpful for the selection of patients for EC-IC bypass surgery. In patients with sickle cell anaemia it has been found that oxygen delivery to the brain is maintained by an increase in cerebral blood flow, whereas the oxygen extraction ratio is not increased despite the presence of a low oxygen affinity haemoglobin. Preliminary observations in classical migraine suggest an ischaemic situation during the attack.

  18. Nitric oxide, prostaglandins and angiotensin II in the regulation of renal medullary blood flow during volume expansion.

    Science.gov (United States)

    Moreno, Carol; Llinás, María T; Rodriguez, Francisca; Moreno, Juan M; Salazar, F Javier

    2016-03-01

    Regulation of medullary blood flow (MBF) is essential in maintaining renal function and blood pressure. However, it is unknown whether outer MBF (OMBF) and papillary blood flow (PBF) are regulated independently when extracellular volume (ECV) is enhanced. The aim of this study was to determine whether OMBF and PBF are differently regulated and whether there is an interaction between nitric oxide (NO), prostaglandins (PGs) and angiotensin II (Ang II) in regulating OMBF and PBF when ECV is enhanced. To achieve these goals, OMBF and PBF were measured by laser-Doppler in volume-expanded rats treated with a cyclooxygenase inhibitor (meclofenamate, 3 mg/kg) and/or a NO synthesis inhibitor (L-nitro-arginine methyl ester (L-NAME), 3 μg/kg/min) and/or Ang II (10 ng/kg/min). OMBF was unchanged by NO or PGs synthesis inhibition but decreased by 36 % (P blood flows to the outer medulla and renal papilla are differently regulated and showing that there is a complex interaction between NO, PGs and Ang II in regulating OMBF and PBF when ECV is enhanced.

  19. Using Hematology Data from Malaria Vaccine Research Trials in Humans and Rhesus Macaques (Macaca mulatta) To Guide Volume Limits for Blood Withdrawal.

    Science.gov (United States)

    Hegge, Sara R; Hickey, Bradley W; Mcgrath, Shannon M; Stewart, V Ann

    2016-12-01

    Guidelines on safe volume limits for blood collection from research participants in both humans and laboratory animals vary widely between institutions. The main adverse event that may be encountered in large blood volume withdrawal is iron-deficiency anemia. Monitoring various parameters in a standard blood panel may help to prevent this outcome. To this end, we analyzed the Hgb and MCV values from 43 humans and 46 macaques in malaria vaccine research trials. Although the percentage of blood volume removed was greater for macaques than humans, macaques demonstrated an overall increase of MCV over time, indicating the ability to respond appropriately to frequent volume withdrawals. In contrast, humans showed a consistent declining trend in MCV. These declines in human MCV and Hgb were significant from the beginning to end of the study despite withdrawals that were smaller than recommended volume limits. Limiting the volume withdrawn to no more than 12.5% seemed to be sufficient for macaques, and at 14% or more individual animals tended to fail to respond appropriately to large-volume blood loss, as demonstrated by a decrease in MCV. The overall positive erythropoietic response seen in macaques was likely due to the controlled, iron-fortified diet they received. The lack of erythropoietic response in the human subjects may warrant iron supplementation or reconsideration of current blood volume withdrawal guidelines.

  20. A simple method to determine the blood volume of newborns with serum-albumin labeled with technetium-99m (HSA-sup(99m)Tc)

    International Nuclear Information System (INIS)

    Camargo, E.E.; Vaz, F.A.C.; Rockmann, R.L.; Barreto, T.M.; Eston, T.E. de; Carvalho, N.

    1973-01-01

    A method for determination of small volumes, with which it is determined blood volume of 11 newborns, is described. By injecting through the anterior fontannelle 1 ml a human serum albumin solution labelled with technetium-99m and withdrawing from the posterior fontanelle blood samples of 1.2 to 1.5 ml at 10, 20 and 30 minutes after the injection, the possibility of determining blood volume with only two of these samples without using a standard is shown. Non-significant whole body radiation (3.2 mrad/6h) is shown as well [pt

  1. Hydration and blood volume effects on human thermoregulation in the heat: Space applications

    Science.gov (United States)

    Sawka, Michael N.; Gonzalez, Richard R.; Pandolf, Kent B.

    1994-01-01

    Astronauts exposed to prolonged weightlessness will experience deconditioning, dehydration, and hypovolemia which all adversely affect thermoregulation. These thermoregulatory problems can be minimized by several countermeasures that manipulate body water and vascular volumes. USARIEM scientists have extensively studied dehydration effects and several possible countermeasures including hyperhydration, plasma and erythrocyte volume expansion. This paper reviews USARIEM research into these areas.

  2. Three-dimensional whole-brain perfused blood volume imaging with multimodal CT for evaluation of acute ischaemic stroke

    International Nuclear Information System (INIS)

    Lu, J.; Zhang, M.; Cao, Y.; Ma, Q.; Chen, J.; Ji, X.; Li, K.

    2011-01-01

    Aim: To determine the diagnostic value of integrating three-dimensional perfused blood volume (3D PBV) with multimodal computed tomography (CT) [non-enhanced CT (NECT), CT perfusion (CTP), and CT angiography (CTA)] in acute ischaemic stroke. Materials and methods: NECT, CTP, and CTA were performed in 25 acute ischaemic stroke patients. The ischaemia detection rate of 3D PBV was compared with the results of baseline NECT and CTP. The correlation of ischaemic lesion volume between 3D PBV, CTP images, and follow-up NECT were analysed. Results: NECT demonstrated ischaemic signs in 12 of 25 patients with proven infarction. CTP maps of cerebral blood flow (CBF), cerebral blood volume (CBV), and time to peak (TTP) all demonstrated perfusion deficits in 21 of 25 patients. However, 3D PBV demonstrated perfusion deficits in all of the 25 patients. Among the 25 patients, a strong correlation was found between PBV and the follow-up NECT infarct (r = 0.858). The correlation between CTP and the follow-up NECT infarct as following: CBF (r = 0.718), CBV (r = 0.785), and TTP (r = 0.569). In 14 thrombolytic patients, strong correlation was found between the ischaemic volume on 3D PBV and follow-up NECT (r = 0.798). Conclusion: In acute stroke patients, the combination of 3D PBV and multimodal CT (NECT, CTP, and CTA) can improve the detection rate of ischaemia and enable assessment of the full extent of ischaemia, which correlates well with follow-up NECT.

  3. 3-D segmentation of retinal blood vessels in spectral-domain OCT volumes of the optic nerve head

    Science.gov (United States)

    Lee, Kyungmoo; Abràmoff, Michael D.; Niemeijer, Meindert; Garvin, Mona K.; Sonka, Milan

    2010-03-01

    Segmentation of retinal blood vessels can provide important information for detecting and tracking retinal vascular diseases including diabetic retinopathy, arterial hypertension, arteriosclerosis and retinopathy of prematurity (ROP). Many studies on 2-D segmentation of retinal blood vessels from a variety of medical images have been performed. However, 3-D segmentation of retinal blood vessels from spectral-domain optical coherence tomography (OCT) volumes, which is capable of providing geometrically accurate vessel models, to the best of our knowledge, has not been previously studied. The purpose of this study is to develop and evaluate a method that can automatically detect 3-D retinal blood vessels from spectral-domain OCT scans centered on the optic nerve head (ONH). The proposed method utilized a fast multiscale 3-D graph search to segment retinal surfaces as well as a triangular mesh-based 3-D graph search to detect retinal blood vessels. An experiment on 30 ONH-centered OCT scans (15 right eye scans and 15 left eye scans) from 15 subjects was performed, and the mean unsigned error in 3-D of the computer segmentations compared with the independent standard obtained from a retinal specialist was 3.4 +/- 2.5 voxels (0.10 +/- 0.07 mm).

  4. WE-FG-206-05: New Arterial Spin Labeling Method for Simultaneous Estimation of Arterial Cerebral Blood Volume, Cerebral Blood Flow and Arterial Transit Time

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, M; Whitlow, C; Jung, Y [Wake Forest School of Medicine, Winston-Salem, NC (United States); Liu, H [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To demonstrate the feasibility of a novel Arterial Spin Labeling (ASL) method for simultaneously measuring cerebral blood flow (CBF), arterial transit time (ATT), and arterial cerebral blood volume (aCBV) without the use of a contrast agent. Methods: A series of multi-TI ASL images were acquired from one healthy subject on a 3T Siemens Skyra, with the following parameters: PCASL labeling with variable TI [300, 400, 500, 600, 700, 800, 900, 1000, 1500, 2000, 2500, 3000, 3500, 4000] ms, labeling bolus 1400 ms when TI allows, otherwise 100 ms less than TI, TR was minimized for each TI, two sinc shaped pre-saturation pulses were applied in the imaging plane immediately before 2D EPI acquisition. 64×64×24 voxels, 5 mm slice thickness, 1 mm gap, full brain coverage, 6 averages per TI, no crusher gradients, 11 ms TE, scan time of 4:56. The perfusion weighted time-series was created for each voxel and fit to a novel model. The model has two components: 1) the traditional model developed by Buxton et al., accounting for CBF and ATT, and 2) a box car function characterizing the width of the labeling bolus, with variable timing and height in proportion to the aCBV. All three parameters were fit using a nonlinear fitting routine that constrained all parameters to be positive. The main purpose of the high-temporal resolution TI sampling for the first second of data acquisition was to precisely estimate the blood volume component for better detection of arrival time and magnitude of signal. Results: Whole brain maps of CBF, ATT, and aCBV were produced, and all three parameters maps are consistent with similar maps described in the literature. Conclusion: Simultaneous mapping of CBF, ATT, and aCBV is feasible with a clinically tractable scan time (under 5 minutes).

  5. Dynamic glucose enhanced (DGE) MRI for combined imaging of blood-brain barrier break down and increased blood volume in brain cancer.

    Science.gov (United States)

    Xu, Xiang; Chan, Kannie W Y; Knutsson, Linda; Artemov, Dmitri; Xu, Jiadi; Liu, Guanshu; Kato, Yoshinori; Lal, Bachchu; Laterra, John; McMahon, Michael T; van Zijl, Peter C M

    2015-12-01

    Recently, natural d-glucose was suggested as a potential biodegradable contrast agent. The feasibility of using d-glucose for dynamic perfusion imaging was explored to detect malignant brain tumors based on blood brain barrier breakdown. Mice were inoculated orthotopically with human U87-EGFRvIII glioma cells. Time-resolved glucose signal changes were detected using chemical exchange saturation transfer (glucoCEST) MRI. Dynamic glucose enhanced (DGE) MRI was used to measure tissue response to an intravenous bolus of d-glucose. DGE images of mouse brains bearing human glioma showed two times higher and persistent changes in tumor compared with contralateral brain. Area-under-curve (AUC) analysis of DGE delineated blood vessels and tumor and had contrast comparable to the AUC determined using dynamic contrast enhanced (DCE) MRI with GdDTPA, both showing a significantly higher AUC in tumor than in brain (P blood volume and permeability with respect to normal brain. We expect DGE will provide a low-risk and less expensive alternative to DCE MRI for imaging cancer in vulnerable populations, such as children and patients with renal impairment. © 2015 Wiley Periodicals, Inc.

  6. Energetic Interrelationship between Spontaneous Low-Frequency Fluctuations in Regional Cerebral Blood Volume, Arterial Blood Pressure, Heart Rate, and Respiratory Rhythm

    Science.gov (United States)

    Katura, Takusige; Yagyu, Akihiko; Obata, Akiko; Yamazaki, Kyoko; Maki, Atsushi; Abe, Masanori; Tanaka, Naoki

    2007-07-01

    Strong spontaneous fluctuations around 0.1 and 0.3 Hz have been observed in blood-related brain-function measurements such as functional magnetic resonance imaging and optical topography (or functional near-infrared spectroscopy). These fluctuations seem to reflect the interaction between the cerebral circulation system and the systemic circulation system. We took an energetic viewpoint in our analysis of the interrelationships between fluctuations in cerebral blood volume (CBV), mean arterial blood pressure (MAP), heart rate (HR), and respiratory rhythm based on multivariate autoregressive modeling. This approach involves evaluating the contribution of each fluctuation or rhythm to specific ones by performing multivariate spectral analysis. The results we obtained show MAP and HR can account slightly for the fluctuation around 0.1 Hz in CBV, while the fluctuation around 0.3 Hz is derived mainly from the respiratory rhythm. During our presentation, we will report on the effects of posture on the interrelationship between the fluctuations and the respiratory rhythm.

  7. The effect of blood volume loss on cardiovascular response to lower body negative pressure using a mathematical model

    Science.gov (United States)

    Karam, E. H.; Srinivasan, R. S.; Charles, J. B.; Fortney, S. M.

    1994-01-01

    Different mathematical models of varying complexity have been proposed in recent years to study the cardiovascular (CV) system. However, only a few of them specifically address the response to lower body negative pressure (LBNP), a stress that can be applied in weightlessness to predict changes in orthostatic tolerance. Also, the simulated results produced by these models agree only partially with experimental observations. In contrast, the model proposed by Melchior et al., and modified by Karam et al. is a simple representation of the CV system capable of accurately reproducing observed LBNP responses up to presyncopal levels. There are significant changes in LBNP response due to a loss of blood volume and other alterations that occur in weightlessness and related one-g conditions such as bedrest. A few days of bedrest can cause up to 15% blood volume loss (BVL), with consequent decreases in both stroke volume and cardiac output, and increases in heart rate, mean arterial pressure, and total peripheral resistance. These changes are more pronounced at higher levels of LBNP. This paper presents the results of a simulation study using our CV model to examine the effect of BVL on LBNP response.

  8. Integrated analysis of halogenated organic pollutants in sub-millilitre volumes of venous and umbilical cord blood sera

    Energy Technology Data Exchange (ETDEWEB)

    Grimalt, Joan O.; Carrizo, Daniel; Otero, Raquel; Vizcaino, Esther [Institute of Environmental Assessment and Water Research (IDAeA-CSIC), Department of Environmental Chemistry, Barcelona, Catalonia (Spain); Howsam, Mike [Universite de Lille 2, Centre Universitaire de Mesure et d' Analyse, Faculte de Pharmacie, Lille (France); Rodrigues de Marchi, Mary Rosa [Institute of Chemistry UNESP, Department of Analytical Chemistry, Araraquara, SP (Brazil)

    2010-03-15

    A rapid, robust and economical method for the analysis of persistent halogenated organic compounds in small volumes of human serum and umbilical cord blood is described. The pollutants studied cover a broad range of molecules of contemporary epidemiological and legislative concern, including polychlorobiphenyls (PCBs), polychlorobenzenes (CBs), hexachlorocyclohexanes (HCHs), DDTs, polychlorostyrenes (PCSs) and polybromodiphenyl ethers (PBDEs). Extraction and clean-up with n-hexane and concentrated sulphuric acid was followed with analysis by gas chromatography coupled to electron capture (GC-ECD) and GC coupled to negative ion chemical ionisation mass spectrometry (GC-NICI-MS). The advantages of this method rest in the broad range of analytes and its simplicity and robustness, while the use of concentrated sulphuric acid extraction/clean-up destroys viruses that may be present in the samples. Small volumes of reference serum between 50 and 1000{mu}L were extracted and the limits of detection/quantification and repeatability were determined. Recoveries of spiked compounds for the extraction of small volumes ({>=}300 {mu}L) of the spiked reference serum were between 90% and 120%. The coefficients of variation of repeatability ranged from 0.1-14%, depending on the compound. Samples of 4-year-old serum and umbilical cord blood (n=73 and 40, respectively) from a population inhabiting a village near a chloro-alkali plant were screened for the above-mentioned halogenated pollutants using this method and the results are briefly described. (orig.)

  9. Elevation of the correlation between cerebral blood volume and permeability surface from CT perfusion images with glioma grade

    International Nuclear Information System (INIS)

    Ding Bei; Ling Huawei; Zhang Huan; Song Qi; Dong Haipeng; Chen Kemin

    2007-01-01

    Objective: To evaluate the correlation between cerebral blood volume and permeability surface by using multislice CT perfusion imaging with glioma grade. Methods: Ninteen patients with gliomas underwent conventional MR and multislice CT perfusion imaging preoperatively. These patients were divided into low grade and high grade groups which were correspond to WHO II grade gliomas and WHO III or IV grade gliomas respectively. CT data were transferred to on-line working station and processed to obtain time-signal curves, color perfusion maps and calculated perfusion parameters, including cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTF) and permeability surfaces (PS) in tumoral parenchyma. Kruskal-Wallis test and correlation of CBV and PS was assessed by using SPSS 11.0 software. Results: The median of CBV and PS in low-grade and high-grade glioma were 2.7, 6.5 ml/100 g; 0.389, 12.810 ml·100 g -1 ·min -1 respectively, corresponding t value were 12.907 13.500 with P<0.05. Pearson correlations between CBV and PS were as follows: in low-grade group, r=-0.058, in high-grade group, r=0.648. Conclusion: Both CBV and PS have obvious correlation with glioma grade. The correlation between CBV and PS in low-grade glioma was weaker, probably because of the focal high vascularity in oligodendroglioma. (authors)

  10. Intraprocedural blood volume measurement using C-arm CT as a predictor for treatment response of malignant liver tumours undergoing repetitive transarterial chemoembolization (TACE)

    International Nuclear Information System (INIS)

    Vogl, Thomas J.; Schaefer, Patrik; Lehnert, Thomas; Mbalisike, Emmanuel; Hammerstingl, Renate; Eichler, Katrin; Zangos, Stephan; Nour-Eldin, Nour-Eldin A.; Ackermann, Hanns; Naguib, Nagy N.N.

    2016-01-01

    To evaluate feasibility of measuring parenchymal blood volume (PBV) of malignant hepatic tumours using C-arm CT, test the changes in PBV following repeated transarterial chemoembolization (TACE) and correlate these changes with the change in tumour size in MRI. 111 patients with liver malignancy were included. Patients underwent MRI and TACE in a 4- to 6-week interval. During intervention C-arm CT was performed. Images were post-processed to generate PBV maps. Blood volume data in C-arm CT and change in size in MRI were evaluated. The correlation between PBV and size was tested using Spearman rank test. Pre-interventional PBV maps showed a mean blood volume of 84.5 ml/1000 ml ± 62.0, follow-up PBV maps after multiple TACE demonstrated 61.1 ml/1000 ml ± 57.5. The change in PBV was statistically significant (p = 0.02). Patients with initial tumour blood volume >100 ml/1000 ml dropped 7.1 % in size and 47.2 % in blood volume; 50-100 ml/1000 ml dropped 4.6 % in size and 25.7 % in blood volume; and <50 ml/1000 ml decreased 2.8 % in size and increased 82.2 % in blood volume. PBV measurement of malignant liver tumours using C-arm CT is feasible. Following TACE PBV decreased significantly. Patients with low initial PBV show low local response rates and further increase in blood volume, whereas high initial tumour PBV showed better response to TACE. (orig.)

  11. Molecular detection of blood pathogens and their impacts on levels of packed cell volume in stray dogs from Thailand

    Directory of Open Access Journals (Sweden)

    Supawadee Piratae

    2017-04-01

    Full Text Available Objective: To evaluate the prevalence of blood parasite infection in stray dogs by PCR technique and the association between levels of packed cell volume (PCV and blood parasitic infection in stray dogs. Methods: A total of 65 blood samples were collected from stray dogs in animal quarantine station from Mahasarakham, Thailand to evaluate the levels of PCV before molecular screening for tick-borne pathogens infection. Results: Stray dogs were positive with one or more pathogens in 44 (67.69% out of 65 blood samples. Ehrlichia canis [43.1%, 95% confidence interval (CI: 38.1–48.1] was the most common blood pathogen found infecting in stray dogs in Mahasarakham Province, followed by Anaplasma platys (29.2%, 95% CI: 24.2–34.2, Hepatozoon canis (12.3%, 95% CI: 7.3–17.3 and Babesia canis vogeli (6.2%, 95% CI: 1.2–11.2, respectively. Moreover, co-infections with two pathogens were identified in 11 (16.9% of dogs examined and two (2.9% dogs were coinfections with three pathogens. Statistically significant relationship between the PCV levels and Ehrlichia canis infection was found (P < 0.05. Conclusions: This study indicated that blood pathogens are spreading in stray dogs and they are potentially high risk of agent transmission to human via exposure with tick vectors. It was also the first report of Anaplasma platys infection in dogs in north-eastern part of Thailand.

  12. Perfusion MRI (dynamic susceptibility contrast imaging) with different measurement approaches for the evaluation of blood flow and blood volume in human gliomas

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, H. (Den Sundhedsfaglige Kandidatuddannelse, Aarhus Universitet Bygning 1264, Aarhus (Denmark); University College Nordjylland, Aalborg (Denmark)), Email: hnt@ucn.dk; Steffensen, E. (Aalborg Hospital/Aarhus University Hospital, Department of Radiology, Aalborg (Denmark)); Larsson, E. M. (Aalborg Hospital/Aarhus University Hospital, Department of Radiology, Aalborg (Denmark); Uppsala University Hospital, Department of Radiology, Uppsala (Sweden))

    2012-02-15

    Background. Perfusion magnetic resonance imaging (MRI) is increasingly used in the evaluation of brain tumors. Relative cerebral blood volume (rCBV) is usually obtained by dynamic susceptibility contrast (DSC) MRI using normal appearing white matter as reference region. The emerging perfusion technique arterial spin labelling (ASL) presently provides measurement only of cerebral blood flow (CBF), which has not been widely used in human brain tumor studies. Purpose. To assess if measurement of blood flow is comparable with measurement of blood volume in human biopsy-proven gliomas obtained by DSC-MRI using two different regions for normalization and two different measurement approaches. Material and Methods. Retrospective study of 61 patients with different types of gliomas examined with DSC perfusion MRI. Regions of interest (ROIs) were placed in tumor portions with maximum perfusion on rCBF and rCBV maps, with contralateral normal appearing white matter and cerebellum as reference regions. Larger ROIs were drawn for histogram analyses. The type and grade of the gliomas were obtained by histopathology. Statistical comparison was made between diffuse astrocytomas, anaplastic astrocytomas, and glioblastomas. Results. rCBF and rCBV measurements obtained with the maximum perfusion method were correlated when normalized to white matter (r = 0.60) and to the cerebellum (r = 0.49). Histogram analyses of rCBF and rCBV showed that mean and median values as well as skewness and peak position were correlated (0.61 < r < 0.93), whereas for kurtosis and peak height, the correlation coefficient was about 0.3 when comparing rCBF and rCBV values for the same reference region. Neither rCBF nor rCBV quantification provided a statistically significant difference between the three types of gliomas. However, both rCBF and rCBV tended to increase with tumor grade and to be lower in patients who had undergone resection/treatment. Conclusion. rCBF measurements normalized to white matter

  13. Determinants of the renin-angiotensin-aldosterone system in cirrhosis with special emphasis on the central blood volume

    DEFF Research Database (Denmark)

    Møller, Søren; Bendtsen, Flemming; Henriksen, Jens H

    2006-01-01

    OBJECTIVE: Several studies have shown activation of the renin-angiotensin-aldosterone system (RAAS) in cirrhosis. Although the activated RAAS may have several determinants, the system is often considered a surrogate marker of effective hypovolaemia. In this study we investigated the activity...... of the RAAS and its potential determinants with special focus on the central and arterial blood volume (CBV). MATERIAL AND METHODS: Eighty-nine patients (Child class A/B/C: 19/41/29) and 32 controls were included in the study. All were given a haemodynamic examination with measurement of determinants...

  14. Relationship between the changes in blood flow and volume in the finger during a Braille character discrimination task.

    Science.gov (United States)

    Murata, J; Murata, S; Soma, M; Nakae, H; Sato, Y; Kogo, H; Umeki, N

    2017-11-01

    We hypothesized that skin blood flow (SBF) of fingers are modulated during concentrated finger perception and that the changes in SBF reflect fluctuations in finger volume (FV). The aim of this study, therefore, was examine the relationship between the changes in SBF and FV during Braille reading. We measured SBF of the finger, cutaneous vascular conductance (CVC), FV, and arterial blood pressure during Braille reading performed under blind conditions in thirty healthy subjects. The subjects were instructed to read a flat plate with raised letters (Braille reading) for 15 seconds using their forefinger, and to touch a blank plate as a control for the Braille discrimination procedure. Arterial blood pressure slightly increased during Braille reading but remained unchanged during the touching of the blank plate. SBF, CVC, and FV were reduced during Braille reading (decreased by -26%, -29%, and -0.3 mL/100 mL respectively). Furthermore, a significant relationship was observed between the changes in SBF and FV (r=.613) during Braille reading. These results suggested that SBF of fingers is modulated during concentrated finger perception, and that the variability of blood flow reflects the response in FV. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Roles of myocardial blood volume and flow in coronary artery disease: an experimental MRI study at rest and during hyperemia

    International Nuclear Information System (INIS)

    McCommis, Kyle S.; Goldstein, Thomas A.; Pilgram, Thomas; Abendschein, Dana R.; Misselwitz, Bernd; Gropler, Robert J.; Zheng, Jie

    2010-01-01

    To validate fast perfusion mapping techniques in a setting of coronary artery stenosis, and to further assess the relationship of absolute myocardial blood volume (MBV) and blood flow (MBF) to global myocardial oxygen demand. A group of 27 mongrel dogs were divided into 10 controls and 17 with acute coronary stenosis. On 1.5-T MRI, first-pass perfusion imaging with a bolus injection of a blood-pool contrast agent was performed to determine myocardial perfusion both at rest and during either dipyridamole-induced vasodilation or dobutamine-induced stress. Regional values of MBF and MBV were quantified by using a fast mapping technique. Color microspheres and 99m Tc-labeled red blood cells were injected to obtain respective gold standards. Microsphere-measured MBF and 99m Tc-measured MBV reference values correlated well with the MR results. Given the same changes in MBF, changes in MBV are twofold greater with dobutamine than with dipyridamole. Under dobutamine stress, MBV shows better association with total myocardial oxygen demand than MBF. Coronary stenosis progressively reduced this association in the presence of increased stenosis severity. MR first-pass perfusion can rapidly estimate regional MBF and MBV. Absolute quantification of MBV may add additional information on stenosis severity and myocardial viability compared with standard qualitative clinical evaluations of myocardial perfusion. (orig.)

  16. Roles of myocardial blood volume and flow in coronary artery disease: an experimental MRI study at rest and during hyperemia

    Science.gov (United States)

    McCommis, Kyle S.; Goldstein, Thomas A.; Abendschein, Dana R.; Misselwitz, Bernd; Pilgram, Thomas; Gropler, Robert J.

    2010-01-01

    Objective To validate fast perfusion mapping techniques in a setting of coronary artery stenosis, and to further assess the relationship of absolute myocardial blood volume (MBV) and blood flow (MBF) to global myocardial oxygen demand. Methods A group of 27 mongrel dogs were divided into 10 controls and 17 with acute coronary stenosis. On 1.5-T MRI, first-pass perfusion imaging with a bolus injection of a blood-pool contrast agent was performed to determine myocardial perfusion both at rest and during either dipyridamole-induced vasodilation or dobutamine-induced stress. Regional values of MBF and MBV were quantified by using a fast mapping technique. Color microspheres and 99mTc-labeled red blood cells were injected to obtain respective gold standards. Results Microsphere-measured MBF and 99mTc-measured MBV reference values correlated well with the MR results. Given the same changes in MBF, changes in MBV are twofold greater with dobutamine than with dipyridamole. Under dobutamine stress, MBV shows better association with total myocardial oxygen demand than MBF. Coronary stenosis progressively reduced this association in the presence of increased stenosis severity. Conclusions MR first-pass perfusion can rapidly estimate regional MBF and MBV. Absolute quantification of MBV may add additional information on stenosis severity and myocardial viability compared with standard qualitative clinical evaluations of myocardial perfusion. PMID:20182731

  17. Relative cerebral blood volume as a marker of durable tissue-at-risk viability in hyperacute ischemic stroke.

    Science.gov (United States)

    Cortijo, Elisa; Calleja, Ana Isabel; García-Bermejo, Pablo; Mulero, Patricia; Pérez-Fernández, Santiago; Reyes, Javier; Muñoz, Ma Fe; Martínez-Galdámez, Mario; Arenillas, Juan Francisco

    2014-01-01

    Selection of best responders to reperfusion therapies could be aided by predicting the duration of tissue-at-risk viability, which may be dependant on collateral circulation status. We aimed to identify the best predictor of good collateral circulation among perfusion computed tomography (PCT) parameters in middle cerebral artery (MCA) ischemic stroke and to analyze how early MCA response to intravenous thrombolysis and PCT-derived markers of good collaterals interact to determine stroke outcome. We prospectively studied patients with acute MCA ischemic stroke treated with intravenous thrombolysis who underwent PCT before treatment showing a target mismatch profile. Collateral status was assessed using a PCT source image-based score. PCT maps were quantitatively analyzed. Cerebral blood volume (CBV), cerebral blood flow, and Tmax were calculated within the hypoperfused volume and in the equivalent region of unaffected hemisphere. Occluded MCAs were monitored by transcranial Duplex to assess early recanalization. Main outcome variables were brain hypodensity volume and modified Rankin scale score at day 90. One hundred patients with MCA ischemic stroke imaged by PCT received intravenous thrombolysis, and 68 met all inclusion criteria. A relative CBV (rCBV) >0.93 emerged as the only predictor of good collaterals (odds ratio, 12.6; 95% confidence interval, 2.9-55.9; P=0.001). Early MCA recanalization was associated with better long-term outcome and lower infarct volume in patients with rCBV<0.93, but not in patients with high rCBV. None of the patients with rCBV<0.93 achieved good outcome in absence of early recanalization. High rCBV was the strongest marker of good collaterals and may characterize durable tissue-at-risk viability in hyperacute MCA ischemic stroke.

  18. Does helmet CPAP reduce cerebral blood flow and volume by comparison with Infant Flow driver CPAP in preterm neonates?

    Science.gov (United States)

    Zaramella, Patrizia; Freato, Federica; Grazzina, Nicoletta; Saraceni, Elisabetta; Vianello, Andrea; Chiandetti, Lino

    2006-10-01

    We compared neonatal helmet continuous positive airway pressure (CPAP) and the conventional nasal Infant Flow driver (IFD) CPAP in the noninvasive assessment of absolute cerebral blood flow (CBF) and relative cerebral blood volume changes (DeltaCBV) by near-infrared spectroscopy. A randomized crossover study in a tertiary referral NICU. Assessment of CBF and DeltaCBV in 17 very low birth weight infants with respiratory distress (median age 5 days) treated with two CPAP devices at a continuous distending pressure of 4 mbar. Neonates were studied for two consecutive 60-min periods with helmet CPAP and with IFD CPAP. Basal chromophore traces enabled DeltaCBV changes to be calculated. CBF was calculated in milliliters per 100 grams per minute from the saturation rise integral and rate of rise O(2)Hb-HHb. Median (range) CBF with helmet CPAP was 27.37 (9.47-48.20) vs. IFD CBF 34.74 (13.59-60.10)(p=0.049) and DeltaCBV 0.15 (0.09-0.28) with IFD and 0.13 (0.07-0.27) with helmet CPAP (NS). Using helmet and IFD CPAP, the neonates showed no difference in mean physiological parameters (transcutaneous carbon dioxide and oxygen tension, pulse oximetry saturation, heart rate, breathing rate, mean arterial blood pressure, desaturation rate, axillary temperature). Assessing CBF and DeltaCBV measured by near-infrared spectroscopy with two CPAP devices revealed no differences in relative blood volume, but CBF was lower with helmet CPAP. Greater active vasoconstriction and/or passive capillary and/or venous vessel compression seem the most likely reason, due to a positive pressure around the head, neck, and shoulders by comparison with the airway pressure.

  19. Volume Tracking: A new method for quantitative assessment and visualization of intracardiac blood flow from three-dimensional, time-resolved, three-component magnetic resonance velocity mapping

    International Nuclear Information System (INIS)

    Töger, Johannes; Carlsson, Marcus; Söderlind, Gustaf; Arheden, Håkan; Heiberg, Einar

    2011-01-01

    Functional and morphological changes of the heart influence blood flow patterns. Therefore, flow patterns may carry diagnostic and prognostic information. Three-dimensional, time-resolved, three-directional phase contrast cardiovascular magnetic resonance (4D PC-CMR) can image flow patterns with unique detail, and using new flow visualization methods may lead to new insights. The aim of this study is to present and validate a novel visualization method with a quantitative potential for blood flow from 4D PC-CMR, called Volume Tracking, and investigate if Volume Tracking complements particle tracing, the most common visualization method used today. Eight healthy volunteers and one patient with a large apical left ventricular aneurysm underwent 4D PC-CMR flow imaging of the whole heart. Volume Tracking and particle tracing visualizations were compared visually side-by-side in a visualization software package. To validate Volume Tracking, the number of particle traces that agreed with the Volume Tracking visualizations was counted and expressed as a percentage of total released particles in mid-diastole and end-diastole respectively. Two independent observers described blood flow patterns in the left ventricle using Volume Tracking visualizations. Volume Tracking was feasible in all eight healthy volunteers and in the patient. Visually, Volume Tracking and particle tracing are complementary methods, showing different aspects of the flow. When validated against particle tracing, on average 90.5% and 87.8% of the particles agreed with the Volume Tracking surface in mid-diastole and end-diastole respectively. Inflow patterns in the left ventricle varied between the subjects, with excellent agreement between observers. The left ventricular inflow pattern in the patient differed from the healthy subjects. Volume Tracking is a new visualization method for blood flow measured by 4D PC-CMR. Volume Tracking complements and provides incremental information compared to particle

  20. Can a central blood volume deficit be detected by systolic pressure variation during spontaneous breathing?

    DEFF Research Database (Denmark)

    Dahl, Michael; Hayes, Chris; Steen Rasmussen, Bodil

    2016-01-01

    BACKGROUND: Whether during spontaneous breathing arterial pressure variations (APV) can detect a volume deficit is not established. We hypothesized that amplification of intra-thoracic pressure oscillations by breathing through resistors would enhance APV to allow identification of a reduced card...

  1. Reliability and validity of non-invasive determined haemoglobin mass and blood volumes

    DEFF Research Database (Denmark)

    Fagoni, Nazzareno; Andersen, Andreas Breenfeldt; Oberholzer, Laura

    2018-01-01

    INTRODUCTION: The carbon monoxide (CO) rebreathing method used for the determination of haemoglobin mass (Hbmass ) is associated with blood sample analysis (in this study: Radiometer ABL800). As an alternative hereto the aim of the present study was to evaluate the use of a portable and non-invas...

  2. Association of Automatically Quantified Total Blood Volume after Aneurysmal Subarachnoid Hemorrhage with Delayed Cerebral Ischemia

    NARCIS (Netherlands)

    Zijlstra, I. A.; Gathier, C. S.; Boers, A. M.; Marquering, H. A.; Slooter, A. J.; Velthuis, B. K.; Coert, B. A.; Verbaan, D.; van den Berg, R.; Rinkel, G. J.; Majoie, C. B.

    2016-01-01

    The total amount of extravasated blood after aneurysmal subarachnoid hemorrhage, assessed with semiquantitative methods such as the modified Fisher and Hijdra scales, is known to be a predictor of delayed cerebral ischemia. However, prediction rates of delayed cerebral ischemia are moderate, which

  3. Quantitative agreement between [(15)O]H2O PET and model free QUASAR MRI-derived cerebral blood flow and arterial blood volume.

    Science.gov (United States)

    Heijtel, D F R; Petersen, E T; Mutsaerts, H J M M; Bakker, E; Schober, P; Stevens, M F; van Berckel, B N M; Majoie, C B L M; Booij, J; van Osch, M J P; van Bavel, E T; Boellaard, R; Lammertsma, A A; Nederveen, A J

    2016-04-01

    The purpose of this study was to assess whether there was an agreement between quantitative cerebral blood flow (CBF) and arterial cerebral blood volume (CBVA) measurements by [(15)O]H2O positron emission tomography (PET) and model-free QUASAR MRI. Twelve healthy subjects were scanned within a week in separate MRI and PET imaging sessions, after which quantitative and qualitative agreement between both modalities was assessed for gray matter, white matter and whole brain region of interests (ROI). The correlation between CBF measurements obtained with both modalities was moderate to high (r(2): 0.28-0.60, P QUASAR significantly underestimated CBF by 30% (P QUASAR yielding values that were only 27% of the [(15)O]H2O-derived values (P QUASAR MRI, indicating similar qualitative CBVA and CBF information by both modalities. In conclusion, the results of this study demonstrate that QUASAR MRI and [(15)O]H2O PET provide similar CBF and CBVA information, but with systematic quantitative discrepancies. Copyright © 2016 John Wiley & Sons, Ltd.

  4. Dynamic Glucose Enhanced (DGE) MRI for Combined Imaging of Blood Brain Barrier Break Down and Increased Blood Volume in Brain Cancer

    Science.gov (United States)

    Xu, Xiang; Chan, Kannie WY; Knutsson, Linda; Artemov, Dmitri; Xu, Jiadi; Liu, Guanshu; Kato, Yoshinori; Lal, Bachchu; Laterra, John; McMahon, Michael T.; van Zijl, Peter C.M.

    2015-01-01

    Purpose Recently, natural d-glucose was suggested as a potential biodegradable contrast agent. The feasibility of using d-glucose for dynamic perfusion imaging was explored to detect malignant brain tumors based on blood brain barrier breakdown. Methods Mice were inoculated orthotopically with human U87-EGFRvIII glioma cells. Time-resolved glucose signal changes were detected using chemical exchange saturation transfer (glucoCEST) MRI. Dynamic glucose enhanced (DGE) MRI was used to measure tissue response to an intravenous bolus of d-glucose. Results DGE images of mouse brains bearing human glioma showed two times higher and persistent changes in tumor compared to contralateral brain. Area-under-curve (AUC) analysis of DGE delineated blood vessels and tumor and had contrast comparable to the AUC determined using dynamic contrast enhanced (DCE) MRI with GdDTPA, both showing a significantly higher AUC in tumor than in brain (pblood volume and permeability with respect to normal brain. We expect DGE will provide a low-risk and less expensive alternative to DCE MRI for imaging cancer in vulnerable populations, such as children and patients with renal impairment. PMID:26404120

  5. Relationship between relative cerebral blood flow, relative cerebral blood volume, and relative cerebral metabolic rate of oxygen in the preterm neonatal brain.

    Science.gov (United States)

    Nourhashemi, Mina; Kongolo, Guy; Mahmoudzadeh, Mahdi; Goudjil, Sabrina; Wallois, Fabrice

    2017-04-01

    The mechanisms responsible for coupling between relative cerebral blood flow (rCBF), relative cerebral blood volume (rCBV), and relative cerebral metabolic rate of oxygen ([Formula: see text]), an important function of the microcirculation in preterm infants, remain unclear. Identification of a causal relationship between rCBF-rCBV and [Formula: see text] in preterms may, therefore, help to elucidate the principles of cortical hemodynamics during development. We simultaneously recorded rCBF and rCBV and estimated [Formula: see text] by two independent acquisition systems: diffuse correlation spectroscopy and near-infrared spectroscopy, respectively, in 10 preterms aged between 28 and 35 weeks of gestational age. Transfer entropy was calculated in order to determine the directionality between rCBF-rCBV and [Formula: see text]. The surrogate method was applied to determine statistical significance. The results show that rCBV and [Formula: see text] have a predominant driving influence on rCBF at the resting state in the preterm neonatal brain. Statistical analysis robustly detected the correct directionality of rCBV on rCBF and [Formula: see text] on rCBF. This study helps to clarify the early organization of the rCBV-rCBF and [Formula: see text] inter-relationship in the immature cortex.

  6. Blood

    Science.gov (United States)

    ... a reduced production of red blood cells, including: Iron deficiency anemia. Iron deficiency anemia is the most common type of anemia and ... inflammatory bowel disease are especially likely to have iron deficiency anemia. Anemia due to chronic disease. People with chronic ...

  7. Peripheral arterial volume distensibility: significant differences with age and blood pressure measured using an applied external pressure

    International Nuclear Information System (INIS)

    Zheng, Dingchang; Murray, Alan

    2011-01-01

    A new arterial distensibility measurement technique was assessed in 100 healthy normotensive subjects. Arterial transmural pressures on the whole right arm were reduced with a 50 cm long cuff inflated to 10, 20, 30 and 40 mmHg. The electrocardiogram, and finger and ear photoplethysmograms were recorded simultaneously. Arm pulse propagation time, pulse wave velocity (PWV) and arterial volume distensibility were determined. With a 40 mmHg reduction in transmural pressure, arm pulse propagation time increased from 61 to 83 ms, PWV decreased from 12 to 8 m s −1 and arterial distensibility increased from 0.102% to 0.232% per mmHg (all P < 0.0001). At all cuff pressures, arterial distensibility was significantly related to resting mean arterial pressure (MAP), diastolic blood pressure (DBP) and age, and for systolic blood pressure at 30 and 40 mmHg (all P < 0.05). At 40 mmHg cuff pressure, arterial distensibility fell by 54% for a MAP increase from 75 to 105 mmHg, 57% for a DBP increase from 60 to 90 mmHg and 47% for an age increase from 20 to 70 years. These changes were more than double than those without cuff pressure. Our technique showed that systemic volume distensibility of the peripheral arm artery reduced with age, with a greater effect at higher external and lower transmural pressures

  8. Comparison of blood volume pulse and skin conductance responses to mental and affective stimuli at different anatomical sites

    International Nuclear Information System (INIS)

    Kushki, Azadeh; Fairley, Jillian; Merja, Satyam; King, Gillian; Chau, Tom

    2011-01-01

    Measurements of blood volume pulse (BVP) and skin conductance are commonly used as indications of psychological arousal in affective computing and human–machine interfaces. To date, palmar surfaces remain the primary site for these measurements. Placement of sensors on palmar surfaces, however, is undesirable when recordings are fraught with motion and pressure artifacts. These artifacts are frequent when the human participant has involuntary movements as in hyperkinetic cerebral palsy. This motivates the use of alternative measurement sites. The present study examined the correlation between measurements of blood volume pulse and skin conductance obtained from three different sites on the body (fingers, toes and ear for BVP; fingers, toes and arch of the foot for skin conductance) in response to cognitive and affective stimuli. The results of this pilot study indicated significant inter-site correlation among signal features derived from different sites, with the exception of BVP amplitude, the number of electrodermal reactions and the slope of the electrodermal activity response. We attribute these differences in part to inter-site discrepancies in local skin conditions, such as skin temperature. Despite these differences, significant changes from baseline were present in the responses to the cognitive and affective stimuli at non-palmar sites, suggesting that these sites may provide viable signal measurements for use in affective computing and human–machine interface applications

  9. Enrichment of circulating tumor cells from a large blood volume using leukapheresis and elutriation: proof of concept.

    Science.gov (United States)

    Eifler, Robert L; Lind, Judith; Falkenhagen, Dieter; Weber, Viktoria; Fischer, Michael B; Zeillinger, Robert

    2011-03-01

    The aim of this study was to determine the applicability of a sequential process using leukapheresis, elutriation, and fluorescence-activated cell sorting (FACS) to enrich and isolate circulating tumor cells from a large blood volume to allow further molecular analysis. Mononuclear cells were collected from 10 L of blood by leukapheresis, to which carboxyfluorescein succinimidyl ester prelabeled CaOV-3 tumor cells were spiked at a ratio of 26 to 10⁶ leukocytes. Elutriation separated the spiked leukapheresates primarily by cell size into distinct fractions, and leukocytes and tumor cells, characterized as carboxyfluorescein succinimidyl ester positive, EpCAM positive and CD45 negative events, were quantified by flow cytometry. Tumor cells were isolated from the last fraction using FACS or anti-EpCAM coupled immunomagnetic beads, and their recovery and purity determined by fluorescent microscopy and real-time PCR. Leukapheresis collected 13.5 x 10⁹ mononuclear cells with 87% efficiency. In total, 53 to 78% of spiked tumor cells were pre-enriched in the last elutriation fraction among 1.6 x 10⁹ monocytes. Flow cytometry predicted a circulating tumor cell purity of ~90% giving an enrichment of 100,000-fold following leukapheresis, elutriation, and FACS, where CaOV-3 cells were identified as EpCAM positive and CD45 negative events. FACS confirmed this purity. Alternatively, immunomagnetic bead adsorption recovered 10% of tumor cells with a median purity of 3.5%. This proof of concept study demonstrated that elutriation and FACS following leukapheresis are able to enrich and isolate tumor cells from a large blood volume for molecular characterization. Copyright © 2010 International Clinical Cytometry Society.

  10. Systemic Immune Activation and HIV Shedding in the Female Genital Tract.

    Science.gov (United States)

    Spencer, LaShonda Y; Christiansen, Shawna; Wang, Chia-Hao H; Mack, Wendy J; Young, Mary; Strickler, Howard D; Anastos, Kathryn; Minkoff, Howard; Cohen, Mardge; Geenblatt, Ruth M; Karim, Roksana; Operskalski, Eva; Frederick, Toni; Homans, James D; Landay, Alan; Kovacs, Andrea

    2016-02-01

    Plasma HIV RNA is the most significant determinant of cervical HIV shedding. However, shedding is also associated with sexually transmitted infections (STIs) and cervical inflammation. The mechanism by which this occurs is poorly understood. There is evidence that systemic immune activation promotes viral entry, replication, and HIV disease progression. We hypothesized that systemic immune activation would be associated with an increase in HIV genital shedding. Clinical assessments, HIV RNA in plasma and genital secretions, and markers of immune activation (CD38(+)DR(+) and CD38(-)DR(-)) on CD4(+) and CD8(+) T cells in blood were evaluated in 226 HIV+ women enrolled in the Women's Interagency HIV Study. There were 569 genital evaluations of which 159 (28%) exhibited HIV RNA shedding, defined as HIV viral load >80 copies per milliliter. We tested associations between immune activation and shedding using generalized estimating equations with logit link function. In the univariate model, higher levels of CD4(+) and CD8(+) T-cell activation in blood were significantly associated with genital tract shedding. However, in the multivariate model adjusting for plasma HIV RNA, STIs, and genital tract infections, only higher levels of resting CD8(+) T cells (CD38(-)DR(-)) were significantly inversely associated with HIV shedding in the genital tract (odds ratios = 0.44, 95% confidence interval: 0.21 to 0.9, P = 0.02). The association of systemic immune activation with genital HIV shedding is multifactorial. Systemic T-cell activation is associated with genital tract shedding in univariate analysis but not when adjusting for plasma HIV RNA, STIs, and genital tract infections. In addition, women with high percentage of resting T cells are less likely to have HIV shedding compared with those with lower percentages. These findings suggest that a higher percentage of resting cells, as a result of maximal viral suppression with treatment, may decrease local genital activation, HIV

  11. Three-dimensional finite volume modelling of blood flow in simulated angular neck abdominal aortic aneurysm

    Science.gov (United States)

    Algabri, Y. A.; Rookkapan, S.; Chatpun, S.

    2017-09-01

    An abdominal aortic aneurysm (AAA) is considered a deadly cardiovascular disease that defined as a focal dilation of blood artery. The healthy aorta size is between 15 and 24 mm based on gender, bodyweight, and age. When the diameter increased to 30 mm or more, the rupture can occur if it is kept growing or untreated. Moreover, the proximal angular neck of aneurysm is categorized as a significant morphological feature with prime harmful effects on endovascular aneurysm repair (EVAR). Flow pattern in pathological vessel can influence the vascular intervention. The aim of this study is to investigate the blood flow behaviours in angular neck abdominal aortic aneurysm with simulated geometry based on patient’s information using computational fluid dynamics (CFD). The 3D angular neck AAA models have been designed by using SolidWorks Software. Consequently, CFD tools are used for simulating these 3D models of angular neck AAA in ANSYS FLUENT Software. Eventually, based on the results, we summarized that the CFD techniques have shown high performance in explaining and investigating the flow patterns for angular neck abdominal aortic aneurysm.

  12. Imaging transient blood vessel fusion events in zebrafish by correlative volume electron microscopy.

    Directory of Open Access Journals (Sweden)

    Hannah E J Armer

    Full Text Available The study of biological processes has become increasingly reliant on obtaining high-resolution spatial and temporal data through imaging techniques. As researchers demand molecular resolution of cellular events in the context of whole organisms, correlation of non-invasive live-organism imaging with electron microscopy in complex three-dimensional samples becomes critical. The developing blood vessels of vertebrates form a highly complex network which cannot be imaged at high resolution using traditional methods. Here we show that the point of fusion between growing blood vessels of transgenic zebrafish, identified in live confocal microscopy, can subsequently be traced through the structure of the organism using Focused Ion Beam/Scanning Electron Microscopy (FIB/SEM and Serial Block Face/Scanning Electron Microscopy (SBF/SEM. The resulting data give unprecedented microanatomical detail of the zebrafish and, for the first time, allow visualization of the ultrastructure of a time-limited biological event within the context of a whole organism.

  13. Improved Load Shedding Scheme considering Distributed Generation

    DEFF Research Database (Denmark)

    Das, Kaushik; Nitsas, Antonios; Altin, Müfit

    2017-01-01

    With high penetration of distributed generation (DG), the conventional under-frequency load shedding (UFLS) face many challenges and may not perform as expected. This article proposes new UFLS schemes, which are designed to overcome the shortcomings of traditional load shedding scheme...

  14. Goodbye, solar shed; Pfiat di, Solarstadl

    Energy Technology Data Exchange (ETDEWEB)

    Diermann, Ralph

    2012-07-01

    In southern Germany, farmers and conservationalists are fighting over new sheds equipped with photovoltaic roofs. The impending amendment of the EEG is expected to solve the conflict. The losers of the game will be the farmers as reimbursement for solar roofs on sheds will be lowered.

  15. Factors affecting the lung perfused blood volume in patients with intrapulmonary clots after anti-coagulation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Munemasa, E-mail: radokada@yamaguchi-u.ac.jp [Department of Radiology, Yamaguchi University Graduate School of Medicine 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan); Masuda, Yu [4th Grade of 6-year Medicine Doctor Program, Department of Medicine, Yamaguchi University Faculty of Medicine and Health Sciences 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan); Nakashima, Yoshiteru [Department of Radiology, Yamaguchi Grand Medical Center, Oosaki 77, Hofu, Yamaguchi 747-8511 (Japan); Nomura, Takafumi; Nakao, Sei [Department of Radiology, Yamaguchi University Graduate School of Medicine 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan); Suga, Kazuyoshi [Department of Radiology, St Hills Hospital, Imamurakita 3-7-18, Ube, Yamaguchi 755-0155 (Japan); Kido, Shoji [Computer-aided Diagnosis and Biomedical Imaging Research Biomedical Engineering, Applied Medical Engineering Science Graduate School of Medicine, Yamaguchi University, Tokiwadai 2-16-1, Ube, Yamaguchi 755-8611 (Japan); Matsunaga, Naofumi [Department of Radiology, Yamaguchi University Graduate School of Medicine 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan)

    2015-08-15

    Highlights: • Dual-energy CT can provide morphological and functional lung images in the same examination. • The subsequent dual-energy CT demonstrates the increased whole lung perfused blood volume (V{sub 120}) despite the residual intrapulmonary clots after treatment in one examination. • The increased whole lung perfusion (V{sub 120}) and a decreased low perfusion volume (V{sub 5}) result in the improvement in the low perfusion rate (%V{sub 5}) in the patients with acute pulmonary embolism after treatment. - Abstract: Objectives: Factors affecting the improvement in the lung perfused blood volume (LPBV) were evaluated based on the presence of intrapulmonary clots (IPCs) after anti-coagulation therapy using 64-slice dual-energy CT. Materials and methods: 96 patients exhibiting venous thromboembolism underwent initial and repeated LPBV examinations between December 2008 and July 2014. Fifteen patients were excluded due to pulmonary comorbidities, and a total of 81 patients were included in this study. Acute pulmonary embolism (PE) was diagnosed in 46 of the patients (56.7%). LPBV images were three-dimensionally reconstructed with two threshold ranges: 1–120 HU (V{sub 120}) and 1–5 HU (V{sub 5}), and the relative value of V{sub 5} per V{sub 120} expressed as %V{sub 5}. These values were subsequently compared with indicators of the severity of PE, such as the D-dimer level, heart rate and CT measurements. This study was approved by the local ethics committee. Results: In patients with IPCs, the D-dimer, V{sub 5} and %V{sub 5}values were significantly larger (p ≤ 0.01) in the initial LPBV, although these differences disappeared in subsequent LPBV after treatment. The right ventricular (RV) diameter, RV/left ventricular (RV/LV) diameter ratio and %V{sub 5} values were also significantly reduced, whereas the V{sub 5} value did not significantly decrease (p = 0.07), but V{sub 120} value significantly increased (p < 0.001) after treatment. However, in

  16. 77 FR 53884 - Automatic Underfrequency Load Shedding and Load Shedding Plans Reliability Standards; Notice of...

    Science.gov (United States)

    2012-09-04

    ... Underfrequency Load Shedding and Load Shedding Plans Reliability Standards; Notice of Compliance Filing Take notice that on August 9, 2012, North American Electric Reliability Corporation submitted a compliance... Load Shedding Plans Reliability Standards, 139 FERC ] 61,098, (Order No. 763) (2012). Any person...

  17. Quantitation of regional cerebral blood flow corrected for partial volume effect using O-15 water and PET

    DEFF Research Database (Denmark)

    IIda, H.; Law, I.; Pakkenberg, B.

    2000-01-01

    Limited spatial resolution of positron emission tomography (PET) can cause significant underestimation in the observed regional radioactivity concentration (so-called partial volume effect or PVE) resulting in systematic errors in estimating quantitative physiologic parameters. The authors have...... formulated four mathematical models that describe the dynamic behavior of a freely diffusible tracer (H215O) in a region of interest (ROI) incorporating estimates of regional tissue flow that are independent of PVE. The current study was intended to evaluate the feasibility of these models and to establish...... a methodology to accurately quantify regional cerebral blood flow (CBF) corrected for PVE in cortical gray matter regions. Five monkeys were studied with PET after IV H2(15)O two times (n = 3) or three times (n = 2) in a row. Two ROIs were drawn on structural magnetic resonance imaging (MRI) scans and projected...

  18. Simultaneous evaluation of brain tumour metabolism, structure and blood volume using [18F]-fluoroethyltyrosine (FET) PET/MRI

    DEFF Research Database (Denmark)

    Henriksen, Otto M.; Larsen, Vibeke A; Muhic, Aida

    2016-01-01

    PURPOSE: Both [(18)F]-fluoroethyltyrosine (FET) PET and blood volume (BV) MRI supplement routine T1-weighted contrast-enhanced MRI in gliomas, but whether the two modalities provide identical or complementary information is unresolved. The aims of the study were to investigate the feasibility...... of simultaneous structural MRI, BV MRI and FET PET of gliomas using an integrated PET/MRI scanner and to assess the spatial and quantitative agreement in tumour imaging between BV MRI and FET PET. METHODS: A total of 32 glioma patients underwent a 20-min static simultaneous PET/MRI acquisition on a Siemens m......MR system 20 min after injection of 200 MBq FET. The MRI protocol included standard structural MRI and dynamic susceptibility contrast (DSC) imaging for BV measurements. Maximal relative tumour FET uptake (TBRmax) and BV (rBVmax), and Dice coefficients were calculated to assess the quantitative and spatial...

  19. Relative cerebral blood volume is associated with collateral status and infarct growth in stroke patients in SWIFT PRIME.

    Science.gov (United States)

    Arenillas, Juan F; Cortijo, Elisa; García-Bermejo, Pablo; Levy, Elad I; Jahan, Reza; Goyal, Mayank; Saver, Jeffrey L; Albers, Gregory W

    2017-01-01

    We aimed to evaluate how predefined candidate cerebral perfusion parameters correlate with collateral circulation status and to assess their capacity to predict infarct growth in patients with acute ischemic stroke (AIS) eligible for endovascular therapy. Patients enrolled in the SWIFT PRIME trial with baseline computed tomography perfusion (CTP) scans were included. RAPID software was used to calculate mean relative cerebral blood volume (rCBV) in hypoperfused regions, and hypoperfusion index ratio (HIR). Blind assessments of collaterals were performed using CT angiography in the whole sample and cerebral angiogram in the endovascular group. Reperfusion was assessed on 27-h CTP; infarct volume was assessed on 27-h magnetic resonance imaging/CT scans. Logistic and rank linear regression models were conducted. We included 158 patients. High rCBV ( p = 0.03) and low HIR ( p = 0.03) were associated with good collaterals. A positive association was found between rCBV and better collateral grades on cerebral angiography ( p = 0.01). Baseline and 27-h follow-up CTP were available for 115 patients, of whom 74 (64%) achieved successful reperfusion. Lower rCBV predicted a higher infarct growth in successfully reperfused patients ( p = 0.038) and in the endovascular treatment group ( p = 0.049). Finally, rCBV and HIR may serve as markers of collateral circulation in AIS patients prior to endovascular therapy. Unique identifier: NCT0165746.

  20. Gliomas: Application of Cumulative Histogram Analysis of Normalized Cerebral Blood Volume on 3 T MRI to Tumor Grading

    Science.gov (United States)

    Kim, Hyungjin; Choi, Seung Hong; Kim, Ji-Hoon; Ryoo, Inseon; Kim, Soo Chin; Yeom, Jeong A.; Shin, Hwaseon; Jung, Seung Chai; Lee, A. Leum; Yun, Tae Jin; Park, Chul-Kee; Sohn, Chul-Ho; Park, Sung-Hye

    2013-01-01

    Background Glioma grading assumes significant importance in that low- and high-grade gliomas display different prognoses and are treated with dissimilar therapeutic strategies. The objective of our study was to retrospectively assess the usefulness of a cumulative normalized cerebral blood volume (nCBV) histogram for glioma grading based on 3 T MRI. Methods From February 2010 to April 2012, 63 patients with astrocytic tumors underwent 3 T MRI with dynamic susceptibility contrast perfusion-weighted imaging. Regions of interest containing the entire tumor volume were drawn on every section of the co-registered relative CBV (rCBV) maps and T2-weighted images. The percentile values from the cumulative nCBV histograms and the other histogram parameters were correlated with tumor grades. Cochran’s Q test and the McNemar test were used to compare the diagnostic accuracies of the histogram parameters after the receiver operating characteristic curve analysis. Using the parameter offering the highest diagnostic accuracy, a validation process was performed with an independent test set of nine patients. Results The 99th percentile of the cumulative nCBV histogram (nCBV C99), mean and peak height differed significantly between low- and high-grade gliomas (P = histogram analysis of nCBV using 3 T MRI can be a useful method for preoperative glioma grading. The nCBV C99 value is helpful in distinguishing high- from low-grade gliomas and grade IV from III gliomas. PMID:23704910

  1. Effect of UVB irradiation of the blood on cellular volume adherence and phagocytosis in probands and patients with multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Mix, E; Jenssen, H L; Lehmitz, R; Buddenhagen, F; Hitzschke, B; Richter, M

    1988-01-01

    UVB-induced changes of blood cell properties were investigated in 12 multiple sclerosis (MS) patients and in 10 healthy volunteers. The mean cell volume (MCV) was determined by electronic sizing, the granulocyte and lymphocyte adherence was estimated in a capillary assay, and the phagocytic activity of granulocytes was measured in a test system based on the incorporation of opsonized baker's yeast. In MS patients the MCV of red cells and lymphocytes decreased rapidly within 6 UVB treatments. In contrast, the reduction of the granulocyte volume was delayed (between the 6th and 12th UVB). In the control group the mean value of the red cell and lymphocyte MCV remained rather unaffected. There was a slight rise of the granulocyte volume after the 6th UVB. The only significant change of adherence was an increase of granulocyte adherence in MS patients. Untreated patients had a significantly enhanced phagocytic activity in comparison to the control group. 6 UVB treatments induced a singificant reduction of the phagocytic activity in MS patients. However, subsequently the percentage of phagocytizing cells increased again, whereas the particle uptake per cell continued to decrease. In the control group only minor UVB-induced changes of phagocytosis were observed. The in vitro UV irradiation caused an enhanced phagocytosis in the majority of cases in both controls and MS patients. In general, under the UVB treatment all parameters examined changed in the sense of a normalisation, in that the measured values reached a new level lying between the extreme pretreatment values accompanied by a reduced standard deviation. The effect of UVB was more pronounced in MS patients when compared with normal control. This could result from an enhanced sensitivity to the influence of UVB of pathologically altered cells in MS patients. (Abstract Truncated)

  2. Effect of UVB irradiation of the blood on cellular volume adherence and phagocytosis in probands and patients with multiple sclerosis

    International Nuclear Information System (INIS)

    Mix, E.; Jenssen, H.L.; Lehmitz, R.; Buddenhagen, F.; Hitzschke, B.; Richter, M.

    1988-01-01

    UVB-induced changes of blood cell properties were investigated in 12 multiple sclerosis (MS) patients and in 10 healthy volunteers. The mean cell volume (MCV) was determined by electronic sizing, the granulocyte and lymphocyte adherence was estimated in a capillary assay, and the phagocytic activity of granulocytes was measured in a test system based on the incorporation of opsonized baker's yeast. In MS patients the MCV of red cells and lymphocytes decreased rapidly within 6 UVB treatments. In contrast, the reduction of the granulocyte volume was delayed (between the 6th and 12th UVB). In the control group the mean value of the red cell and lymphocyte MCV remained rather unaffected. There was a slight rise of the granulocyte volume after the 6th UVB. The only significant change of adherence was an increase of granulocyte adherence in MS patients. Untreated patients had a significantly enhanced phagocytic activity in comparison to the control group. 6 UVB treatments induced a singificant reduction of the phagocytic activity in MS patients. However, subsequently the percentage of phagocytizing cells increased again, whereas the particle uptake per cell continued to decrease. In the control group only minor UVB-induced changes of phagocytosis were observed. The in vitro UV irradiation caused an enhanced phagocytosis in the majority of cases in both controls and MS patients. In general, under the UVB treatment all parameters examined changed in the sense of a normalisation, in that the measured values reached a new level lying between the extreme pretreatment values accompanied by a reduced standard deviation. The effect of UVB was more pronounced in MS patients when compared with normal control. This could result from an enhanced sensitivity to the influence of UVB of pathologically altered cells in MS patients. The monitoring of the MCV of red cells and lymphocytes as well as the repeated testing of granulocyte phagocytosis are recommended for supportion of therapy

  3. Myocardial Blood Volume Is Associated with Myocardial Oxygen Consumption: An Experimental Study with CMR in a Canine Model

    Science.gov (United States)

    McCommis, Kyle S.; Zhang, Haosen; Goldstein, Thomas A.; Misselwitz, Bernd; Abendschein, Dana R.; Gropler, Robert J.; Zheng, Jie

    2009-01-01

    OBJECTIVES To evaluate the feasibility of cardiovascular MR (CMR) to determine regional myocardial perfusion and O2 metabolism, and assess the role of myocardial blood volume (MBV) on oxygen supply. BACKGROUND Coronary artery disease presents as an imbalance of myocardial oxygen supply and demand. We have developed relevant CMR methods to determine the relationship of myocardial blood flow (MBF) and MBV to oxygen consumption (MVO2) during pharmacologic hyperemia. METHODS Twenty-one mongrel dogs were studied with varying stenosis severities imposed on the proximal left anterior descending (LAD) coronary artery. MBF and MBV were determined by CMR first-pass perfusion, while the oxygen extraction fraction (OEF) and MVO2 were determined by the myocardial Blood-Oxygen-Level-Dependent (BOLD) effect and Fick’s law, respectively. MR imaging was performed at rest, and during either dipyridamole-induced vasodilation or dobutamine-induced hyperemia. Regional differences in myocardial perfusion and oxygenation were then evaluated. RESULTS Dipyridamole and dobutamine both led to 145–200% increases in MBF and 50–80% increases in MBV in normal perfused myocardium. As expected, MVO2 increased more significantly with dobutamine (~175%) than dipyridamole (~40%). Coronary stenosis resulted in an attenuation of MBF, MBV, and MVO2 in both the LAD-subtended stenosis region and the left circumflex subtended remote region. Liner regression analysis showed that MBV reserve appears to be more correlated with MVO2 reserve during dobutamine stress than MBF reserve, particularly in the stenotic regions. Conversely, MBF reserve appears to be more correlated with MVO2 reserve during dipyridamole, although neither of these differences was significant. CONCLUSIONS Noninvasive evaluation of both myocardial perfusion and oxygenation by CMR facilitates direct monitoring of regional myocardial ischemia and provides a valuable tool for better understanding microvascular pathophysiology. These

  4. Blood volume-monitored regulation of ultrafiltration in fluid-overloaded hemodialysis patients: study protocol for a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Hecking Manfred

    2012-06-01

    Full Text Available Abstract Background Data generated with the body composition monitor (BCM, Fresenius show, based on bioimpedance technology, that chronic fluid overload in hemodialysis patients is associated with poor survival. However, removing excess fluid by lowering dry weight can be accompanied by intradialytic and postdialytic complications. Here, we aim at testing the hypothesis that, in comparison to conventional hemodialysis, blood volume-monitored regulation of ultrafiltration and dialysate conductivity (UCR and/or regulation of ultrafiltration and temperature (UTR will decrease complications when ultrafiltration volumes are systematically increased in fluid-overloaded hemodialysis patients. Methods/design BCM measurements yield results on fluid overload (in liters, relative to extracellular water (ECW. In this prospective, multicenter, triple-arm, parallel-group, crossover, randomized, controlled clinical trial, we use BCM measurements, routinely introduced in our three maintenance hemodialysis centers shortly prior to the start of the study, to recruit sixty hemodialysis patients with fluid overload (defined as ≥15% ECW. Patients are randomized 1:1:1 into UCR, UTR and conventional hemodialysis groups. BCM-determined, ‘final’ dry weight is set to normohydration weight −7% of ECW postdialysis, and reached by reducing the previous dry weight, in steps of 0.1 kg per 10 kg body weight, during 12 hemodialysis sessions (one study phase. In case of intradialytic complications, dry weight reduction is decreased, according to a prespecified algorithm. A comparison of intra- and post-dialytic complications among study groups constitutes the primary endpoint. In addition, we will assess relative weight reduction, changes in residual renal function, quality of life measures, and predialysis levels of various laboratory parameters including C-reactive protein, troponin T, and N-terminal pro-B-type natriuretic peptide, before and after the first study

  5. Identification of shed or plucked origin of Indian peafowl (Pavo cristatus) tail feathers: preliminary findings.

    Science.gov (United States)

    Sahajpal, Vivek; Goyal, S P

    2008-06-01

    Indian Peafowl (Pavo cristatus) tail covert feathers were studied to investigate the difference between shed and plucked feathers in the context of wildlife offence cases involving the killing of the Indian national bird for the purpose of plucking feathers. Plucked feathers were distinguished from shed feathers by examining their roots under low magnification of a stereoscopic microscope. A chemical test to show the presence of blood on the roots of plucked feathers was used to corroborate the plucked origin of feathers.

  6. Volume Tracking: A new method for quantitative assessment and visualization of intracardiac blood flow from three-dimensional, time-resolved, three-component magnetic resonance velocity mapping

    Directory of Open Access Journals (Sweden)

    Arheden Håkan

    2011-04-01

    Full Text Available Abstract Background Functional and morphological changes of the heart influence blood flow patterns. Therefore, flow patterns may carry diagnostic and prognostic information. Three-dimensional, time-resolved, three-directional phase contrast cardiovascular magnetic resonance (4D PC-CMR can image flow patterns with unique detail, and using new flow visualization methods may lead to new insights. The aim of this study is to present and validate a novel visualization method with a quantitative potential for blood flow from 4D PC-CMR, called Volume Tracking, and investigate if Volume Tracking complements particle tracing, the most common visualization method used today. Methods Eight healthy volunteers and one patient with a large apical left ventricular aneurysm underwent 4D PC-CMR flow imaging of the whole heart. Volume Tracking and particle tracing visualizations were compared visually side-by-side in a visualization software package. To validate Volume Tracking, the number of particle traces that agreed with the Volume Tracking visualizations was counted and expressed as a percentage of total released particles in mid-diastole and end-diastole respectively. Two independent observers described blood flow patterns in the left ventricle using Volume Tracking visualizations. Results Volume Tracking was feasible in all eight healthy volunteers and in the patient. Visually, Volume Tracking and particle tracing are complementary methods, showing different aspects of the flow. When validated against particle tracing, on average 90.5% and 87.8% of the particles agreed with the Volume Tracking surface in mid-diastole and end-diastole respectively. Inflow patterns in the left ventricle varied between the subjects, with excellent agreement between observers. The left ventricular inflow pattern in the patient differed from the healthy subjects. Conclusion Volume Tracking is a new visualization method for blood flow measured by 4D PC-CMR. Volume Tracking

  7. The prediction of radiofrequency ablation zone volume using vascular indices of 3-dimensional volumetric colour Doppler ultrasound in an in vitro blood-perfused bovine liver model

    Science.gov (United States)

    Lanctot, Anthony C; McCarter, Martin D; Roberts, Katherine M; Glueck, Deborah H; Dodd, Gerald D

    2017-01-01

    Objective: To determine the most reliable predictor of radiofrequency (RF) ablation zone volume among three-dimensional (3D) volumetric colour Doppler vascular indices in an in vitro blood-perfused bovine liver model. Methods: 3D colour Doppler volume data of the local hepatic parenchyma were acquired from 37 areas of 13 bovine livers connected to an in vitro oxygenated blood perfusion system. Doppler vascular indices of vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were obtained from the volume data using 3D volume analysis software. 37 RF ablations were performed at the same locations where the ultrasound data were obtained from. The relationship of these vascular indices and the ablation zone volumes measured from gross specimens were analyzed using a general linear mixed model fit with random effect for liver and backward stepwise regression analysis. Results: FI was significantly associated with ablation zone volumes measured on gross specimens (p = 0.0047), but explained little of the variance (Rβ2 = 0.21). Ablation zone volume decreased by 0.23 cm3 (95% confidence interval: −0.38, −0.08) for every 1 increase in FI. Neither VI nor VFI was significantly associated with ablation zone volumes (p > 0.05). Conclusion: Although FI was associated with ablation zone volumes, it could not sufficiently explain their variability, limiting its clinical applicability. VI, FI and VFI are not clinically useful in the prediction of RF ablation zone volume in the liver. Advances in knowledge: Despite a significant association of FI with ablation zone volumes, VI, FI and VFI cannot be used for their prediction. Different Doppler vascular indices need to be investigated for clinical use. PMID:27925468

  8. Effect of age on heart rate, blood lactate concentration, packed cell volume and hemoglobin to exercise in Jeju crossbreed horses

    Directory of Open Access Journals (Sweden)

    Ok-Deuk Kang

    2017-01-01

    Full Text Available Abstract Background This study aimed to analyze the on heart rate, blood lactate concentration, packed cell volume (PCV and hemoglobin (Hb response after conducting exercise in endurance horses. Methods A total of 20 healthy 3–9-years-old Jeju crossbreed mares (5.95 ± 2.24 year of age and 312.65 ± 13.59 kg of weight currently participating the endurance competition were used. The field tests selected for the experiment was gallop (approximately 8.3 m/s along the selected 2.5 km course (a natural forest trail, not artificial road; a closed loop course. The horses were divided into three groups according to their age; 3–4 years of age (G1, 3.29 ± 0.49 year, 6–7 years of age (G2, 6.42 ± 0.53, and 8–9 years of age (G3, 8.50 ± 0.55. The measurements times for the heart rate, blood lactate concentration, PCV, and Hb analysis were conducted before exercise (T0, shortly after exercise (T1, 15 min after exercise (T2, and 30 min after exercise (T3, respectively. Data was analyzed using an analysis of covariance (ANCOVA for repeated measures with times and groups. Results The results of the comparison depending on the passage of rest time after exercise suggest that the heart rate and blood lactate concentration of three groups at T2 significantly decreased compared to T1 (p < 0.001. PCV of the G2 and G3 groups were significantly decreased at T2 compared to T1 (p < 0.01. Hb values at G2 (p < 0.01 and G3 (p < 0.001 groups were significantly decreased at T2 as compared to T1. However, heart rate, blood lactate concentration, PCV and Hb level at T1 showed no difference in the comparison of horses from different age groups with the exception of G3 group in terms of heart rate. Conclusion The physiologic and hematological responses of horses during recovery time after 2,500 m exercise with gallop were no significant difference among the groups. These data are useful as a response evaluation method for

  9. The volume of the carotid bodies and blood pressure variability and pulse pressure in patients with essential hypertension

    International Nuclear Information System (INIS)

    Jaźwiec, P.; Gać, P.; Poręba, M.; Sobieszczańska, M.; Mazur, G.; Poręba, R.

    2016-01-01

    Aim: To assess the relationship between the volume of the carotid bodies (V rCB+lCB ) examined by means of computed tomography angiography (CTA) and blood pressure variability and pulse pressure (PP) in 24-hour ambulatory blood pressure monitoring (ABPM) in patients with essential hypertension. Materials and methods: A group of 52 patients with essential hypertension was examined (mean age: 68.32±12.31 years), the sizes of carotid bodies were measured by means of carotid artery CTA, and 24-hour ABPM was carried out. The 24-hour ABPM established systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), PP, SBP variability (SBPV), and DBP variability (DBPV). Results: SBP, MAP, and SBPV were significantly higher in the group of hypertension patients with V rCB+lCB equal to or above the median than in the group of hypertension patients with V rCB+lCB less than the median, as well as in the group of hypertension patients with oversized carotid bodies, than in the group of hypertension patients with normal V rCB+lCB . Moreover, the PP was statistically significantly higher in the group of hypertension patients with V rCB+lCB equal to or above the median than in the group of hypertension patients with V rCB+lCB less than the median. The existence of statistically significant positive linear relationships was revealed between V rCB+lCB and SBP, PP, and SBPV. A higher body mass index, older age, smoking, and higher V rCB+lCB are independent risk factors increasing SBPV in the research group. Conclusion: A positive relationship between the size of the carotid bodies and variability of the SBP and PP is observed in patients with essential hypertension. - Highlights: • Purpose. Determination of the relationships: V rCB+lCB vs. BPV and V rCB+lCB vs. PP. • Positive linear correlations were documented between V rCB+lCB and SBP, PP and SBPV. • Higher BMI, age, V rCB+lCB and smoking are independent risk factor of increased SBPV.

  10. Smart fast blood counting of trace volumes of body fluids from various mammalian species using a compact custom-built microscope cytometer (Conference Presentation)

    Science.gov (United States)

    Smith, Zachary J.; Gao, Tingjuan; Lin, Tzu-Yin; Carrade-Holt, Danielle; Lane, Stephen M.; Matthews, Dennis L.; Dwyre, Denis M.; Wachsmann-Hogiu, Sebastian

    2016-03-01

    Cell counting in human body fluids such as blood, urine, and CSF is a critical step in the diagnostic process for many diseases. Current automated methods for cell counting are based on flow cytometry systems. However, these automated methods are bulky, costly, require significant user expertise, and are not well suited to counting cells in fluids other than blood. Therefore, their use is limited to large central laboratories that process enough volume of blood to recoup the significant capital investment these instruments require. We present in this talk a combination of a (1) low-cost microscope system, (2) simple sample preparation method, and (3) fully automated analysis designed for providing cell counts in blood and body fluids. We show results on both humans and companion and farm animals, showing that accurate red cell, white cell, and platelet counts, as well as hemoglobin concentration, can be accurately obtained in blood, as well as a 3-part white cell differential in human samples. We can also accurately count red and white cells in body fluids with a limit of detection ~3 orders of magnitude smaller than current automated instruments. This method uses less than 1 microliter of blood, and less than 5 microliters of body fluids to make its measurements, making it highly compatible with finger-stick style collections, as well as appropriate for small animals such as laboratory mice where larger volume blood collections are dangerous to the animal's health.

  11. Real-time contrast-enhanced ultrasound determination of microvascular blood volume in abdominal subcutaneous adipose tissue in man. Evidence for adipose tissue capillary recruitment

    DEFF Research Database (Denmark)

    Tobin, L; Simonsen, L; Bülow, J

    2010-01-01

    The adipose tissue metabolism is dependent on its blood perfusion. During lipid mobilization e.g. during exercise and during lipid deposition e.g. postprandial, adipose tissue blood flow is increased. This increase in blood flow may involve capillary recruitment in the tissue. We investigated...... of ultrasound contrast agent to establish the reproducibility of the technique. In nine subjects, the effect of an oral glucose load on blood flow and microvascular volume was measured in abdominal subcutaneous adipose tissue and forearm skeletal muscle. ¹³³Xe washout and venous occlusion strain......-gauge plethysmography was used to measure the adipose tissue and forearm blood flow, respectively. Ultrasound signal intensity of the first plateau phases was 27 ± dB in the abdominal subcutaneous adipose tissue and 18 ± 2 dB (P

  12. A new method to study changes in microvascular blood volume in muscle and adipose tissue: Real time imaging in humans and rat

    DEFF Research Database (Denmark)

    Sjøberg, Kim Anker; Rattigan, Stephen; Hiscock, Natalie J

    2011-01-01

    We employed and evaluated a new application of contrast enhanced ultrasound for real time imaging of changes in microvascular blood volume (MVB) in tissues in females, males and rat. Continuous real time imaging was performed using contrast enhanced ultrasound to quantify infused gas filled micro...

  13. Effect of hysteroscopic adhesiolysis combined with growth hormone on endometrial blood flow and volume as well as Smad2/3 expression

    Directory of Open Access Journals (Sweden)

    Xing-Chan Li

    2016-10-01

    Full Text Available Objective: To study the effect of hysteroscopic adhesiolysis combined with growth hormone on endometrial blood flow and volume as well as Smad2/3 expression. Methods: A total of 64 patients with moderate or severe intrauterine adhesions who received hysteroscopic adhesiolysis in our hospital from May 2013 to October 2015 were selected as the research subjects and randomly divided into two groups who received different postoperative drug treatment, observation group received postoperative manual cycle intervention combined with growth hormone treatment and control group only received manual cycle intervention. Transvaginal ultrasonography was conducted after treatment to assess endometrial thickness, volume and blood flow, and endometrium was collected to determine Smad2, Smad3 and TGF- β1 levels. Results: After treatment, endometrial blood flow signal of observation group was more abundant than that of control group, ultrasound parameters RI and PI were significantly lower than those of control group, and VI, FI and VFI as well as endometrial thickness and endometrial cavity volume were significantly higher than those of control group; Smad2, Smad3 and TGF-β1 levels in endometrial tissue of observation group after treatment were significantly lower than those of control group. Conclusions: Hysteroscopic adhesiolysis combined with growth hormone therapy can promote endometrial repair and growth, increase endometrial blood flow and volume and also suppress the expression of Smad2/3 and TGF-β1 in patients with intrauterine adhesions.

  14. Blood-retinal barrier glycerol permeability in diabetic macular edema and healthy eyes: estimations from macular volume changes after peroral glycerol

    DEFF Research Database (Denmark)

    Thornit, Dorte Nellemann; Vinten, Carl Martin; Sander, Birgit

    2010-01-01

    PURPOSE: To compare the changes in macular volume (MV) between healthy subjects and patients with diabetic macular edema (DME) after an osmotic load and to determine the glycerol permeability (P(gly)) of the blood-retinal barrier (BRB). METHODS: In this unmasked study, 13 patients with DME and 5...

  15. Role of the adrenal medulla in control of blood pressure and renal function during furosemide-induced volume depletion

    DEFF Research Database (Denmark)

    Hasbak, Philip; Petersen, Jørgen Søberg; Shalmi, Michael

    1995-01-01

    Farmakologi, furosemide, adrenaline, renal function, adrenal medullectomy, arterial blood pressure......Farmakologi, furosemide, adrenaline, renal function, adrenal medullectomy, arterial blood pressure...

  16. Red Blood Cell Transfusion Need for Elective Primary Posterior Lumbar Fusion in A High-Volume Center for Spine Surgery

    Science.gov (United States)

    Ristagno, Giuseppe; Beluffi, Simonetta; Tanzi, Dario; Belloli, Federica; Carmagnini, Paola; Croci, Massimo; D’Aviri, Giuseppe; Menasce, Guido; Pastore, Juan C.; Pellanda, Armando; Pollini, Alberto; Savoia, Giorgio

    2018-01-01

    (1) Background: This study evaluated the perioperative red blood cell (RBC) transfusion need and determined predictors for transfusion in patients undergoing elective primary lumbar posterior spine fusion in a high-volume center for spine surgery. (2) Methods: Data from all patients undergoing spine surgery between 1 January 2014 and 31 December 2016 were reviewed. Patients’ demographics and comorbidities, perioperative laboratory results, and operative time were analyzed in relation to RBC transfusion. Multivariate logistic regression analysis was performed to identify the predictors of transfusion. (3) Results: A total of 874 elective surgeries for primary spine fusion were performed over the three years. Only 54 cases (6%) required RBC transfusion. Compared to the non-transfused patients, transfused patients were mainly female (p = 0.0008), significantly older, with a higher ASA grade (p = 0.0002), and with lower pre-surgery hemoglobin (HB) level and hematocrit (p < 0.0001). In the multivariate logistic regression, a lower pre-surgery HB (OR (95% CI) 2.84 (2.11–3.82)), a higher ASA class (1.77 (1.03–3.05)) and a longer operative time (1.02 (1.01–1.02)) were independently associated with RBC transfusion. (4) Conclusions: In the instance of elective surgery for primary posterior lumbar fusion in a high-volume center for spine surgery, the need for RBC transfusion is low. Factors anticipating transfusion should be taken into consideration in the patient’s pre-surgery preparation. PMID:29385760

  17. Red Blood Cell Transfusion Need for Elective Primary Posterior Lumbar Fusion in A High-Volume Center for Spine Surgery

    Directory of Open Access Journals (Sweden)

    Giuseppe Ristagno

    2018-01-01

    Full Text Available (1 Background: This study evaluated the perioperative red blood cell (RBC transfusion need and determined predictors for transfusion in patients undergoing elective primary lumbar posterior spine fusion in a high-volume center for spine surgery. (2 Methods: Data from all patients undergoing spine surgery between 1 January 2014 and 31 December 2016 were reviewed. Patients’ demographics and comorbidities, perioperative laboratory results, and operative time were analyzed in relation to RBC transfusion. Multivariate logistic regression analysis was performed to identify the predictors of transfusion. (3 Results: A total of 874 elective surgeries for primary spine fusion were performed over the three years. Only 54 cases (6% required RBC transfusion. Compared to the non-transfused patients, transfused patients were mainly female (p = 0.0008, significantly older, with a higher ASA grade (p = 0.0002, and with lower pre-surgery hemoglobin (HB level and hematocrit (p < 0.0001. In the multivariate logistic regression, a lower pre-surgery HB (OR (95% CI 2.84 (2.11–3.82, a higher ASA class (1.77 (1.03–3.05 and a longer operative time (1.02 (1.01–1.02 were independently associated with RBC transfusion. (4 Conclusions: In the instance of elective surgery for primary posterior lumbar fusion in a high-volume center for spine surgery, the need for RBC transfusion is low. Factors anticipating transfusion should be taken into consideration in the patient’s pre-surgery preparation.

  18. Hepatic blood flow and splanchnic oxygen consumption in patients with liver failure. Effect of high-volume plasmapheresis.

    Science.gov (United States)

    Clemmesen, J O; Gerbes, A L; Gülberg, V; Hansen, B A; Larsen, F S; Skak, C; Tygstrup, N; Ott, P

    1999-02-01

    Liver failure represents a major therapeutic challenge, and yet basic pathophysiological questions about hepatic perfusion and oxygenation in this condition have been poorly investigated. In this study, hepatic blood flow (HBF) and splanchnic oxygen delivery (DO2, sp) and oxygen consumption (VO2,sp) were assessed in patients with liver failure defined as hepatic encephalopathy grade II or more. Measurements were repeated after high-volume plasmapheresis (HVP) with exchange of 8 to 10 L of plasma. HBF was estimated by use of constant infusion of D-sorbitol and calculated according to Fick's principle from peripheral artery and hepatic vein concentrations. In 14 patients with acute liver failure (ALF), HBF (1.78 +/- 0.78 L/min) and VO2,sp (3.9 +/- 0.9 mmol/min) were higher than in 11 patients without liver disease (1.07 +/- 0.19 L/min, P HVP, HBF increased from 1.67 +/- 0.72 to 2.07 +/- 1.11 L/min (n=11) in ALF, and from 1.89 +/- 1.32 to 2.34 +/- 1.54 L/min (n=7) in AOCLD, P HVP. Blood flow was redirected to the liver as the systemic vascular resistance index increased (1,587 +/- 650 vs. 2, 020 +/- 806 Dyne. s. cm-5. m2, P HVP, but as cardiac output increased from 9.1 +/- 2.8 to 10.1 +/- 2.9 L/min (P HVP (n=18), DO2,sp increased by 15% (P HVP. Changes of ET-1 were positively correlated with changes in HBF (P HVP (P HVP did not correlate. Our data suggest that liver failure is associated with increased HBF and VO2, sp. HVP further increased HBF and DO2,sp but VO2,sp was unchanged, indicating that splanchnic hypoxia was not present.

  19. Radionuclide-determined changes in pulmonary blood volume and thallium lung uptake in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Wilson, R.A.; Okada, R.D.; Boucher, C.A.; Strauss, H.W.; Pohost, G.M.

    1983-01-01

    Exercise-induced increases in radionuclide-determined pulmonary blood volume (PBV) and thallium lung uptake have been described in patients with coronary artery disease (CAD) and have been shown to correlate with transient exercise-induced left ventricular dysfunction. To compare these 2 techniques in the same patients, 74 patients (59 with and 15 without significant CAD) underwent supine bicycle exercise twice on the same day--first for thallium myocardial and lung imaging and then for technetium-99m gated blood pool imaging for the PBV ratio determination. Thallium activity of lung and myocardium was determined to calculate thallium lung/heart ratio. Relative changes in PBV from rest to exercise were expressed as a ratio of pulmonary counts (exercise/rest). Previously reported normal ranges for thallium lung/heart ratio and PBV ratio were used. The PBV ratio and thallium lung/heart ratio were abnormal in 71 and 36%, respectively, of patients with CAD (p less than 0.01). Both ratios were normal in all patients without CAD. Although the resting ejection fractions did not differ significantly in patients with normal versus those with abnormal PBV ratios or thallium lung/heart ratios, abnormal PBV ratios and thallium lung/heart ratios were associated with an exercise-induced decrease in ejection fraction. Propranolol use was significantly higher in patients with abnormal than in those with normal thallium lung/heart ratios (p less than 0.01). No significant difference in propranolol use was present in patients with abnormal or normal PBV ratios. In conclusion: (1) the prevalence of an abnormal thallium lung/heart ratio is less than that of the PBV ratio in patients with CAD; (2) both tests are normal in normal control subjects; (3) propranolol does not cause abnormal results in normal control subjects; however, propranolol may influence lung thallium uptake in patients with CAD; and (4) when both tests are abnormal, there is a high likelihood of multivessel disease

  20. High "normal" blood glucose is associated with decreased brain volume and cognitive performance in the 60s: the PATH through life study.

    Directory of Open Access Journals (Sweden)

    Moyra E Mortby

    Full Text Available Type 2 diabetes is associated with cerebral atrophy, cognitive impairment and dementia. We recently showed higher glucose levels in the normal range not to be free of adverse effects and to be associated with greater hippocampal and amygdalar atrophy in older community-dwelling individuals free of diabetes.This study aimed to determine whether blood glucose levels in the normal range (<6.1 mmol/L were associated with cerebral volumes in structures other than the hippocampus and amygdale, and whether these glucose-related regional volumes were associated with cognitive performance.210 cognitively healthy individuals (68-73 years without diabetes, glucose intolerance or metabolic syndrome were assessed in the large, community-based Personality and Total Health Through Life (PATH study.Baseline blood glucose levels in the normal range (3.2-6.1 mmol/l were used to determine regional brain volumes and associated cognitive function at wave 3.Higher blood glucose levels in the normal range were associated with lower grey/white matter regional volumes in the frontal cortices (middle frontal gyrus, inferior frontal gyrus precentral gyrus. Moreover, identified cerebral regions were associated with poorer cognitive performance and the structure-function associations were gender specific to men.These findings stress the need to re-evaluate what is considered as healthy blood glucose levels, and consider the role of higher normal blood glucose as a risk factor for cerebral health, cognitive function and dementia. A better lifetime management of blood glucose levels may contribute to improved cerebral and cognitive health in later life and possibly protect against dementia.

  1. MR-based cerebral blood volume maps as a diagnostic tool of stroke: results of a clinical pilot study

    International Nuclear Information System (INIS)

    Hacklaender, T.; Hofer, M.; Binkofski, F.; Reichenbach, J.; Moedder, U.

    1996-01-01

    In this study the sensitivity of proving a stroke using regional cerebral blood volume (rCBV) maps were investigated. Another aim was to evaluate the strength of the ischaemia. Seven patients were examined during the acute phase of a stroke, eight during the subacute or chronically stage. To calculate rCBV-maps of one slice low dosed Gd-DTPA was injected as a bolus. Using the relaxation-effect the obtained signal intensity-time curves were converted pixel-wise to rCBV images. For the region of the infarction rCBV ratios were calculated relative to the corresponding area in the contralateral hemisphere. Only 63% of the investigations carried out during the acute phase were utilizable. In all those cases a decrease of rCBV was found. The infarct area could only be visually recognized if the rCBV ratio was lower than 0.7. The ratios of completely and partical necrotic areas of the infarctions were 0.481 and 1.028 respectively. With a p=0.0015 these values are even statistically different. During the acute stage the sensitivity of the rCBV measurement was not as high as that of morphological MR imaging. However, rCBV maps make it possible to estimate the strength of the ischaemia even during the first hours. (orig./MG) [de

  2. Near-infrared spectroscopy measurement of the pulsatile component of cerebral blood flow and volume from arterial oscillations

    Science.gov (United States)

    Themelis, George; D'Arceuil, Helen; Diamond, Solomon G.; Thaker, Sonal; Huppert, Theodore J.; Boas, David A.

    2009-01-01

    We describe a near-infrared spectroscopy (NIRS) method to noninvasively measure relative changes in the pulsate components of cerebral blood flow (pCBF) and volume (pCBV) from the shape of heartbeat oscillations. We present a model that is used and data to show the feasibility of the method. We use a continuous-wave NIRS system to measure the arterial oscillations originating in the brains of piglets. Changes in the animals' CBF are induced by adding CO2 to the breathing gas. To study the influence of scalp on our measurements, comparative, invasive measurements are performed on one side of the head simultaneously with noninvasive measurements on the other side. We also did comparative measurements of CBF using a laser Doppler system to validate the results of our method. The results indicate that for sufficient source-detector separation, the signal contribution of the scalp is minimal and the measurements are representative of the cerebral hemodynamics. Moreover, good correlation between the results of the laser Doppler system and the NIRS system indicate that the presented method is capable of measuring relative changes in CBF. Preliminary results show the potential of this NIRS method to measure pCBF and pCBV relative changes in neonatal pigs. PMID:17343508

  3. Influence of vascular enhancement, age and gender on pulmonary perfused blood volume quantified by dual-energy-CTPA

    International Nuclear Information System (INIS)

    Meinel, Felix G.; Graef, Anita; Sommer, Wieland H.; Thierfelder, Kolja M.; Reiser, Maximilian F.; Johnson, Thorsten R.C.

    2013-01-01

    Objectives: To determine the influence of technical and demographic parameters on quantification of pulmonary perfused blood volume (PBV) in dual energy computed tomography pulmonary angiography (DE-CTPA). Materials and methods: Pulmonary PBV was quantified in 142 patients who underwent DE-CTPA for suspected pulmonary embolism but in whom no thoracic pathologies were detected. Multivariate linear regression analysis was performed to calculate the influence of age, gender, enhancement of pulmonary trunk and enhancement difference between pulmonary trunk and left atrium (as a measure of timing) on PBV values. The resulting regression coefficients were used to calculate age-specific ranges of normal for PBV values adjusted for vascular enhancement and timing. Results: Enhancement of the pulmonary trunk (β = −0.29, p = 0.001) and enhancement difference between pulmonary trunk and left atrium (β = −0.24, p = 0.003) were found to significantly influence PBV values. Age (β = −0.33, p < 0.001) but not gender (β = 0.14, p = 0.05) had a significant negative influence on pulmonary PBV values. There was a 20% relative decrease of pulmonary PBV from patients aged <30 to patients over 80 years of age. Conclusions: DE-CTPA derived PBV values need to be corrected for age, vascular enhancement and timing but not for gender. The age-specific ranges of normal derived from this study can be used as a reference in future studies of PBV in pulmonary pathologies

  4. Non-invasive estimation of the human pulmonary blood volume with gamma camera and RI-angiocardiography

    International Nuclear Information System (INIS)

    Goto, Koshi; Hirano, Akihiko; Hirakawa, Senri

    1981-01-01

    A new, non-invasive method for the estimation of the human pulmonary blood volume (PBV), existing between the pulmonary artery bifurcation (PAB) and the left atrium (LA), has been developed in this laboratory, in the form of PBV = PPT sub(RCG) x 0.77 x CO, equation (6), given in Appendix. This was an extension of the classical Stewart-Hamilton method of indicator dilution, applied to radioisotope angiocardiography. Using a gamma-camera, the radio-isotope (99 m Tc-albumin) dilution curves were recorded externally at the region of PAB, LA and LV (left ventricle), among other things, in human subjects in supine position. The mean transit time (MTT) was determined for each region, and the difference in MTT, e.g., ΔMTT sub(PAB-LA), was measured. We calculated PBV between PAB and LA as PBV = ΔMTT sub(PAB-LA) x CO, equation (1) given in Appendix. Empirical time relations between ΔMTT sub(PAB-LA) and PPT sub(RCG) were examined in mechanical models and human subjects, through several steps represented by equations (2) to (5), given in Appendix, and our tentatively final formula was equation (6). The values of PBV estimated in this way were in good agreement with those of PBV measured invasively in the past, using two injection sites (PA and LA) and one sampling site (artery). (author)

  5. The heart rate increase at the onset of high-work intensity exercise is accelerated by central blood volume loading.

    Science.gov (United States)

    Miyamoto, Tadayoshi; Oshima, Yoshitake; Ikuta, Komei; Kinoshita, Hiroshi

    2006-01-01

    Using a water immersion (WI) method, the combined effect of central blood volume (CBV) loading and work intensity on the time course of heart rate (HR) at the onset of upright dynamic exercise was investigated. Seven males cranked a cycle ergometer for 12 min using their un-immersed arms at low-, moderate- and high-work intensities, followed by a 12-min rest. For WI, the pre-exercise resting cardiac output increased by 36%, while HR decreased by 22% [from 76.8 (10.4) to 59.6 (9.8) beats/min]. WI also increased the high-frequency (HF, 0.15-0.40 Hz) component of the HR variability, suggesting an increased vagal activity. During the initial 2 min of the exercise period at low-work intensity, HR increased by 34.9 and 25.8% in the WI and control conditions, respectively. These were 117 and 73% at high-work intensity, indicating more accelerated HR with WI than the control. The plasma norepinephrine concentration increased less during high-work intensity exercise during WI, as compared to exercise during control conditions. In conclusion, the HR increase at the onset of high-work intensity exercise is accelerated by CBV loading but not at low intensity, possibly reflecting vago-sympathetic interaction and reduced baroreflex sensitivity.

  6. Dynamic Contrast-Enhanced Computed Tomography-Derived Blood Volume and Blood Flow Correlate With Patient Outcome in Metastatic Renal Cell Carcinoma.

    Science.gov (United States)

    Mains, Jill Rachel; Donskov, Frede; Pedersen, Erik Morre; Madsen, Hans Henrik Torp; Rasmussen, Finn

    2017-02-01

    The aim was to explore the potential for using dynamic contrast-enhanced computed tomography as a noninvasive functional imaging biomarker before and during the early treatment of metastatic renal cell carcinoma (mRCC). Dynamic contrast-enhanced computed tomography scans were performed at baseline and after 5 and 10 weeks' treatment in 69 prospectively included mRCC patients receiving treatment with interferon alpha and interleukin 2 (n = 26); interferon alpha, interleukin 2, and bevacizumab (n = 24); sunitinib (n = 7); pazopanib (n = 5); or temsirolimus (n = 7). Using a prototype software program (Advanced Perfusion and Permeability Application, Philips Healthcare, Best, the Netherlands), blood volume (BV), blood flow (BF), and permeability surface area product (PS) were calculated for each tumor at baseline, week 5, and week 10. These parameters as well as relative changes between baseline and weeks 5 and 10 were tested for associations with progression-free survival (PFS) and overall survival (OS) using Kaplan-Meier curves and log-rank tests. Using the 25th percentile as the cutoff, baseline BV for all patients independent of subsequent treatment was statistically significantly associated with PFS (10.8 vs 5.3 months, P = 0.007) and OS (35.2 vs 13.3 months, P = 0.001), and baseline BF was significantly associated with OS (31.7 vs 14.6 months, P = 0.024) with high values for both parameters being associated with significantly longer PFS and OS. Baseline PS was not associated with PFS or OS.In patients treated with angiogenesis inhibitors (bevacizumab, sunitinib, pazopanib, or temsirolimus), the relative change in BV from baseline to week 5 using 25th percentile as the cutoff was associated with PFS (5.6 vs 24.8 months, P = 0.001) and OS (19.1 months vs not reached, P = 0.008) and from baseline to week 10 with PFS (8.1 vs 16.4 months, P = 0.014) and OS (15.5 months vs not reached, P = 0.002). The relative change in BF from baseline to week 5 using medians as the

  7. Vortex Shedding Inside a Baffled Air Duct

    Science.gov (United States)

    Davis, Philip; Kenny, R. Jeremy

    2010-01-01

    Common in the operation of both segmented and un-segmented large solid rocket motors is the occurrence of vortex shedding within the motor chamber. A portion of the energy within a shed vortex is converted to acoustic energy, potentially driving the longitudinal acoustic modes of the motor in a quasi-discrete fashion. This vortex shedding-acoustic mode excitation event occurs for every Reusable Solid Rocket Motor (RSRM) operation, giving rise to subsequent axial thrust oscillations. In order to better understand this vortex shedding/acoustic mode excitation phenomena, unsteady CFD simulations were run for both a test geometry and the full scale RSRM geometry. This paper covers the results from the subscale geometry runs, which were based on work focusing on the RSRM hydrodynamics. Unsteady CFD simulation parameters, including boundary conditions and post-processing returns, are reviewed. The results were further post-processed to identify active acoustic modes and vortex shedding characteristics. Probable locations for acoustic energy generation, and subsequent acoustic mode excitation, are discussed.

  8. Effect of volume loading on the Frank-Starling relation during reductions in central blood volume in heat-stressed humans

    DEFF Research Database (Denmark)

    Bundgaard-Nielsen, Morten; Wilson, T E; Seifert, Thomas

    2010-01-01

    -body heating after intravascular volume expansion. Volume expansion was accomplished by administration of a combination of a synthetic colloid (HES 130/0.4, Voluven) and saline. Before LBNP, SV was not affected by heating (122 +/- 30 ml; mean +/- s.d.) compared to normothermia (110 +/- 20 ml; P = 0...

  9. In a Canine Pneumonia Model of Exchange-Transfusion, Altering the Age but Not the Volume of Older Red Blood Cells Markedly Alters Outcome

    Science.gov (United States)

    Cortés-Puch, Irene; Remy, Kenneth E.; Solomon, Steven B.; Sun, Junfeng; Wang, Dong; Al-Hamad, Mariam; Kelly, Seth M.; Sinchar, Derek; Bellavia, Landon; Kanias, Tamir; Popovsky, Mark A.; Kim-Shapiro, Daniel B.; Klein, Harvey G.; Natanson, Charles

    2015-01-01

    Background Massive exchange-transfusion of 42-day-old red blood cells (RBCs) in a canine model of S. aureus pneumonia resulted in in vivo hemolysis with increases in cell-free hemoglobin (CFH), transferrin bound iron (TBI), non-transferrin bound iron (NTBI), and mortality. We have previously shown that washing 42-day-old RBCs before transfusion significantly decreased NTBI levels and mortality, but washing 7-day-old RBCs increased mortality and CFH levels. We now report the results of altering volume, washing, and age of RBCs. Study Design and Methods Two-year-old purpose-bred infected beagles were transfused with increasing volumes (5-10, 20-40, or 60-80 mL/kg) of either 42- or 7-day-old RBCs (n=36) or 80 mL/kg of either unwashed or washed RBCs with increasing storage age (14, 21, 28, or 35 days) (n=40). Results All volumes transfused (5-80 mL/kg) of 42-day-old RBCs, resulted in alike (i.e., not significantly different) increases in TBI during transfusion as well as in CFH, lung injury, and mortality rates after transfusion. Transfusion of 80 mL/kg of RBCs stored for 14, 21, 28 and 35 days resulted in increased CFH and NTBI in between levels found at 7 and 42 days of storage. However, washing RBCs of intermediate ages (14-35 days) does not alter NTBI and CFH levels or mortality rates. Conclusions Preclinical data suggest that any volume of 42-day-old blood potentially increases risks during established infection. In contrast, even massive volumes of 7-day-old blood result in minimal CFH and NTBI levels and risks. In contrast to the extremes of storage, washing blood stored for intermediate ages does not alter risks of transfusion or NTBI and CFH clearance. PMID:26469998

  10. SU-G-IeP1-12: Size Selective Arterial Cerebral Blood Volume Mapping Using Multiple Inversion Time Arterial Spin Labeling

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Y; Johnston, M; Whitlow, C [Wake Forest School of Medicine, Winston-salem, NC (United States); Liu, H [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To demonstrate the feasibility of a novel method for size specific arterial cerebral blood volume (aCBV) mapping using pseudo-continuous arterial spin labeling (PCASL), with multiple TI. Methods: Multiple PCASL images were obtained from a subject with TI of [300, 400, 500, 600, 700, 800, 900, 1000, 1500, 2000, 2500, 3000, 3500, 4000] ms. Each TI pair was averaged six times. Two scans were performed: one without a flow crusher gradient and the other with a crusher gradient (10cm/s in three directions) to remove signals from large arteries. Scan times were 5min. without a crusher gradient and 5.5 min with a crusher gradient. Non-linear fitting algorithm finds the minimum mean squared solution of per-voxel based aCBV, cerebral blood flow, and arterial transit time, and fits the data into a hemodynamic model that represents superposition of blood volume and flow components within a single voxel. Results: aCBV maps with a crusher gradient represent signals from medium and small sized arteries, while those without a crusher gradient represent signals from all sized arteries, indicating that flow crusher gradients can be effectively employed to achieve size-specific aCBV mapping. Regardless of flow crusher, the CBF and ATT maps are very similar in appearance. Conclusion: Quantitative size selective blood volume mapping controlled by a flow crusher is feasible without additional information because the ASL quantification process doesn’t require an arterial input function measured from a large artery. The size specific blood volume mapping is not interfered by sSignals from large arteries do not interfere with size specific aCBV mapping in the applications of interest in for applications in which only medium or small arteries are of interest.

  11. Quantification of serial changes in cerebral blood volume and metabolism in patients with recurrent glioblastoma undergoing antiangiogenic therapy

    Energy Technology Data Exchange (ETDEWEB)

    Stadlbauer, Andreas, E-mail: andi@nmr.at [Institute of Medical Radiology, University Clinic of St. Pölten, Propst Führer-Straße 4, A-3100 St. Pölten (Austria); Department of Neurosurgery, University of Erlangen-Nuremberg, Schwabachanlage 6, D-91054 Erlangen (Germany); Department of Radiology and Nuclear Medicine, Medical University Vienna, Währinger Gürtel 18-20, A-1097 Vienna (Austria); Pichler, Petra [First Department of Internal Medicine, University Clinic of St. Pölten, Propst Führer-Straße 4, A-3100 St. Poelten (Austria); Karl, Marianne [Institute of Medical Radiology, University Clinic of St. Pölten, Propst Führer-Straße 4, A-3100 St. Pölten (Austria); Brandner, Sebastian [Department of Neurosurgery, University of Erlangen-Nuremberg, Schwabachanlage 6, D-91054 Erlangen (Germany); Lerch, Claudia [Institute of Medical Radiology, University Clinic of St. Pölten, Propst Führer-Straße 4, A-3100 St. Pölten (Austria); Renner, Bertold [Institute of Experimental and Clinical Pharmacology and Toxicology, University of Erlangen-Nürnberg, Erlangen (Germany); Heinz, Gertraud [Institute of Medical Radiology, University Clinic of St. Pölten, Propst Führer-Straße 4, A-3100 St. Pölten (Austria)

    2015-06-15

    Highlights: • Antiangiogenic therapy can lead to a decreased in CBV in normal brain tissue. • Responding and pseudoresponding lesions to AAT showed a similar CBV decrease. • Cho and NAA allowed for a distinction of responding and pseudoresponding lesions. • Cr ratios are not suited for evaluation of antiangiogenic therapy response. • Responders to AAT may have an increased risk for remote progression of the GBM. - Abstract: Objectives: To evaluate the usefulness of quantitative advanced magnetic resonance imaging (MRI) methods for assessment of antiangiogenic therapy (AAT) response in recurrent glioblastoma multiforme (GBM). Methods: Eighteen patients with recurrent GBM received bevacizumab and 18 patients served as control group. Baseline MRI and two follow-up examinations were acquired every 3–5 months using dynamic susceptibility-weighted contrast (DSC) perfusion MRI and {sup 1}H-MR spectroscopic imaging ({sup 1}H-MRSI). Maps of absolute cerebral blood volume (aCBV) were coregistered with choline (Cho) and N-acetyl-aspartate (NAA) concentrations and compared to usually used relative parameters as well as controls. Results: Perfusion significantly decreased in responding and pseudoresponding GBMs but also in normal appearing brain after AAT onset. Cho and NAA concentrations were superior to Cr-ratios in lesion differentiation and showed a clear gap between responding and pseudoresponding lesions. Responders to AAT exceptionally frequently (6 out of 8 patients) showed remote GBM progression. Conclusions: Quantification of CBV reveals changes in normal brain perfusion due to AAT, which were not described so far. DSC perfusion MRI seems not to be suitable for differentiation between response and pseudoresponse to AAT. However, absolute quantification of brain metabolites may allow for distinction due to a clear gap at 6–9 months after therapy onset.

  12. Added value of lung perfused blood volume images using dual-energy CT for assessment of acute pulmonary embolism

    International Nuclear Information System (INIS)

    Okada, Munemasa; Kunihiro, Yoshie; Nakashima, Yoshiteru; Nomura, Takafumi; Kudomi, Shohei; Yonezawa, Teppei; Suga, Kazuyoshi; Matsunaga, Naofumi

    2015-01-01

    Purpose: To investigate the added value of lung perfused blood volume (LPBV) using dual-energy CT for the evaluation of intrapulmonary clot (IPC) in patients suspected of having acute pulmonary embolism (PE). Materials and methods: Institutional review board approval was obtained for this retrospective study. Eighty-three patients suspected of having PE who underwent CT pulmonary angiography (CTPA) using a dual-energy technique were enrolled in this study. Two radiologists who were blinded retrospectively and independently reviewed CTPA images alone and the combined images with color-coded LPBV over a 4-week interval, and two separate sessions were performed with a one-month interval. Inter- and intraobserver variability and diagnostic accuracy were evaluated for each reviewer with receiver operating characteristic (ROC) curve analysis. Results: Values for inter- and intraobserver agreement, respectively, were better for CTPA combined with LPBV (ICC = 0.847 and 0.937) than CTPA alone (ICC = 0.748 and 0.861). For both readers, diagnostic accuracy (area under the ROC curve [A z ]) were also superior, when CTPA alone (A z = 0.888 [reader 1] and 0.912 [reader 2]) was compared with that after the combination with LPBV images (A z = 0.966 [reader 1] and 0.959 [reader 2]) (p < 0.001). However, A z values of both images might not have significant difference in statistics, because A z value of CTPA alone was high and 95% confidence intervals overlapped in both images. Conclusion: Addition of dual-energy perfusion CT to CTPA improves detection of peripheral IPCs with better interobserver agreement

  13. Suramin-restricted blood volume in the placenta of normal and diabetic rats is normalized by vitamin E treatment.

    Science.gov (United States)

    Nash, P; Eriksson, U J

    2007-01-01

    Previously maternal and fetal alterations resembling human pre-eclampsia were induced in pregnant rats by injections of the angiogenesis inhibitor Suramin. These alterations were aggravated by maternal diabetes and partly rectified by vitamin E supplementation. In the present study we evaluated the morphology of placentae and kidneys in this model. Non-diabetic and streptozotocin-induced diabetic pregnant rats of two rat strains (U and H) were treated with Suramin or saline, and given standard or vitamin E-enriched food. On gestational day 20 one placenta and the left kidney of the mother were collected for morphological and stereological analysis. In the placental trophospongium Suramin treatment caused cysts, which were further enhanced by maternal diabetes. Vitamin E treatment had no effect on the vacuolization. In the placental labyrinth of the non-diabetic rats Suramin treatment restricted maternal placental blood volume and increased the interface between maternal and fetal circulation. These changes were reversed by vitamin E treatment. Diabetes increased slightly the interface between the circulations in both rat strains. Suramin treatment decreased the interface, and vitamin E further decreased the interface in the diabetic U rats, whereas neither treatment affected the maternal-fetal interface in the diabetic H rats. The kidneys of Suramin-treated and diabetic rats were heavier compared to controls. Suramin treatment and maternal diabetes damaged renal glomeruli to a similar extent. Vitamin E treatment diminished the Suramin- and diabetes-induced glomerular damage in U rats, but not in H rats. The average cell count per glomerulus was decreased by Suramin in the U rats. Vitamin E treatment did not affect cell number per glomerulus in any group. We conclude that Suramin-injected pregnant rats constitute a valid animal model for placental dysfunction and pre-eclampsia, also from the histological perspective. The present work supports the notion that one

  14. Determination of the total blood volume of the rat using chromium 51 (1962); Determination du volume sanguin total chez le rat a l'aide du chrome 51 (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Bernard, Y; Rinaldi, R [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1962-07-01

    In various experiments it is important that the rat's blood volume should be known and it is essential that it could be worked out by simply weighing the animal. Therefore authors decided to work out systematically with chromium 51 blood volume for rats with different weights. Results have shown that blood volume for 100 g is 5.55 ml and that it does not seen to vary with the weight of animals. (authors) [French] La connaissance de la masse sanguine chez le rat est indispensable dans de nombreuses experiences et il est essentiel de pouvoir l'evaluer apres une simple pesee de l'animal. C'est dans ce but que les auteurs ont entrepris la determination systematique de la masse sanguine a l'aide du chrome 51 chez des rats de poids differents. Les resultats obtenus ont montre que la masse sanguine rapportee a 100 grammes d'animal est de 5,53 millilitres, et qu'elle ne parait pas varier avec le poids de l'animal. (auteurs)

  15. Microparticle Shedding from Neural Progenitor Cells and Vascular Compartment Cells Is Increased in Ischemic Stroke.

    Science.gov (United States)

    Chiva-Blanch, Gemma; Suades, Rosa; Crespo, Javier; Peña, Esther; Padró, Teresa; Jiménez-Xarrié, Elena; Martí-Fàbregas, Joan; Badimon, Lina

    2016-01-01

    Ischemic stroke has shown to induce platelet and endothelial microparticle shedding, but whether stroke induces microparticle shedding from additional blood and vascular compartment cells is unclear. Neural precursor cells have been shown to replace dying neurons at sites of brain injury; however, if neural precursor cell activation is associated to microparticle shedding, and whether this activation is maintained at long term and associates to stroke type and severity remains unknown. We analyzed neural precursor cells and blood and vascular compartment cells microparticle shedding after an acute ischemic stroke. Forty-four patients were included in the study within the first 48h after the onset of stroke. The cerebral lesion size was evaluated at 3-7 days of the stroke. Circulating microparticles from neural precursor cells and blood and vascular compartment cells (platelets, endothelial cells, erythrocytes, leukocytes, lymphocytes, monocytes and smooth muscle cells) were analyzed by flow cytometry at the onset of stroke and at 7 and 90 days. Forty-four age-matched high cardiovascular risk subjects without documented vascular disease were used as controls. Compared to high cardiovascular risk controls, patients showed higher number of neural precursor cell- and all blood and vascular compartment cell-derived microparticles at the onset of stroke, and after 7 and 90 days. At 90 days, neural precursor cell-derived microparticles decreased and smooth muscle cell-derived microparticles increased compared to levels at the onset of stroke, but only in those patients with the highest stroke-induced cerebral lesions. Stroke increases blood and vascular compartment cell and neural precursor cell microparticle shedding, an effect that is chronically maintained up to 90 days after the ischemic event. These results show that stroke induces a generalized blood and vascular cell activation and the initiation of neuronal cell repair process after stroke. Larger cerebral lesions

  16. Microparticle Shedding from Neural Progenitor Cells and Vascular Compartment Cells Is Increased in Ischemic Stroke.

    Directory of Open Access Journals (Sweden)

    Gemma Chiva-Blanch

    Full Text Available Ischemic stroke has shown to induce platelet and endothelial microparticle shedding, but whether stroke induces microparticle shedding from additional blood and vascular compartment cells is unclear. Neural precursor cells have been shown to replace dying neurons at sites of brain injury; however, if neural precursor cell activation is associated to microparticle shedding, and whether this activation is maintained at long term and associates to stroke type and severity remains unknown. We analyzed neural precursor cells and blood and vascular compartment cells microparticle shedding after an acute ischemic stroke.Forty-four patients were included in the study within the first 48h after the onset of stroke. The cerebral lesion size was evaluated at 3-7 days of the stroke. Circulating microparticles from neural precursor cells and blood and vascular compartment cells (platelets, endothelial cells, erythrocytes, leukocytes, lymphocytes, monocytes and smooth muscle cells were analyzed by flow cytometry at the onset of stroke and at 7 and 90 days. Forty-four age-matched high cardiovascular risk subjects without documented vascular disease were used as controls.Compared to high cardiovascular risk controls, patients showed higher number of neural precursor cell- and all blood and vascular compartment cell-derived microparticles at the onset of stroke, and after 7 and 90 days. At 90 days, neural precursor cell-derived microparticles decreased and smooth muscle cell-derived microparticles increased compared to levels at the onset of stroke, but only in those patients with the highest stroke-induced cerebral lesions.Stroke increases blood and vascular compartment cell and neural precursor cell microparticle shedding, an effect that is chronically maintained up to 90 days after the ischemic event. These results show that stroke induces a generalized blood and vascular cell activation and the initiation of neuronal cell repair process after stroke. Larger

  17. Early Prediction of Outcome in Advanced Head-and-Neck Cancer Based on Tumor Blood Volume Alterations During Therapy: A Prospective Study

    International Nuclear Information System (INIS)

    Cao Yue; Popovtzer, Aron; Li, Diana; Chepeha, Douglas B.; Moyer, Jeffrey S.; Prince, Mark E.; Worden, Francis; Teknos, Theodoros; Bradford, Carol; Mukherji, Suresh K.; Eisbruch, Avraham

    2008-01-01

    Purpose: To assess whether alterations in tumor blood volume (BV) and blood flow (BF) during the early course of chemo-radiotherapy (chemo-RT) for head-and-neck cancer (HNC) predict treatment outcome. Methods and Materials: Fourteen patients receiving concomitant chemo-RT for nonresectable, locally advanced HNC underwent dynamic contrast-enhanced (DCE) MRI scans before therapy and 2 weeks after initiation of chemo-RT. The BV and BF were quantified from DCE MRI. Preradiotherapy BV and BF, as well as their changes during RT, were evaluated separately in the primary gross tumor volume (GTV) and nodal GTV for association with outcomes. Results: At a median follow-up of 10 months (range, 5-27 months), 9 patients had local-regional controlled disease. One patient had regional failure, 3 had local failures, and 1 had local-regional failure. Reduction in tumor volume after 2 weeks of chemo-RT did not predict for local control. In contrast, the BV in the primary GTV after 2 weeks of chemo-RT was increased significantly in the local control patients compared with the local failure patients (p < 0.03). Conclusions: Our data suggest that an increase in available primary tumor blood for oxygen extraction during the early course of RT is associated with local control, thus yielding a predictor with potential to modify treatment. These findings require validation in larger studies

  18. Carbogen Breathing Differentially Enhances Blood Plasma Volume and 5-Fluorouracil Uptake in Two Murine Colon Tumor Models with a Distinct Vascular Structure

    Directory of Open Access Journals (Sweden)

    Hanneke W.M. van Laarhoven

    2006-06-01

    Full Text Available For the systemic treatment of colorectal cancer, 5-fluorouracil (FU-based chemotherapy is the standard. However, only a subset of patients responds to chemotherapy. Breathing of carbogen (95% O2 and 5% CO2 may increase the uptake of FU through changes in tumor physiology. This study aims to monitor in animal models in vivo the effects of carbogen breathing on tumor blood plasma volume, pH, and energy status, and on FU uptake and metabolism in two colon tumor models C38 and C26a, which differ in their vascular structure and hypoxic status. Phosphorus-31 magnetic resonance spectroscopy (MRS was used to assess tumor pH and energy status, and fluorine-19 MRS was used to follow FU uptake and metabolism. Advanced magnetic resonance imaging methods using ultrasmall particles of iron oxide were performed to assess blood plasma volume. The results showed that carbogen breathing significantly decreased extracellular pH and increased tumor blood plasma volume and FU uptake in tumors. These effects were most significant in the C38 tumor line, which has the largest relative vascular area. In the C26a tumor line, carbogen breathing increased tumor growth delay by FU. In this study, carbogen breathing also enhanced systemic toxicity by FU.

  19. Blood parasites, total plasma protein and packed cell volume of small wild mammals trapped in three mountain ranges of the Atlantic Forest in Southeastern Brazil

    Directory of Open Access Journals (Sweden)

    MAML. Silva

    Full Text Available A study of blood parasites in small wild non-flying mammals was undertaken in three areas of the Atlantic Forest in Southeastern Brazil: Serra de Itatiaia, RJ, Serra da Bocaina, SP and Serra da Fartura, SP, from June 1999 to May 2001. A total of 450 animals (15 species were captured in traps and it was observed in 15.5% of the blood smears the presence of Haemobartonella sp. and Babesia sp. in red blood cells. There was no statistically significant difference between parasited and non-parasited specimens regarding total plasma protein, packed cell volume and body weight, which strongly suggests that these specimens might be parasite reservoirs.

  20. [Interpretation and use of routine pulmonary function tests: Spirometry, static lung volumes, lung diffusion, arterial blood gas, methacholine challenge test and 6-minute walk test].

    Science.gov (United States)

    Bokov, P; Delclaux, C

    2016-02-01

    Resting pulmonary function tests (PFT) include the assessment of ventilatory capacity: spirometry (forced expiratory flows and mobilisable volumes) and static volume assessment, notably using body plethysmography. Spirometry allows the potential definition of obstructive defect, while static volume assessment allows the potential definition of restrictive defect (decrease in total lung capacity) and thoracic hyperinflation (increase in static volumes). It must be kept in mind that this evaluation is incomplete and that an assessment of ventilatory demand is often warranted, especially when facing dyspnoea: evaluation of arterial blood gas (searching for respiratory insufficiency) and measurement of the transfer coefficient of the lung, allowing with the measurement of alveolar volume to calculate the diffusing capacity of the lung for CO (DLCO: assessment of alveolar-capillary wall and capillary blood volume). All these pulmonary function tests have been the subject of an Americano-European Task force (standardisation of lung function testing) published in 2005, and translated in French in 2007. Interpretative strategies for lung function tests have been recommended, which define abnormal lung function tests using the 5th and 95th percentiles of predicted values (lower and upper limits of normal values). Thus, these recommendations need to be implemented in all pulmonary function test units. A methacholine challenge test will only be performed in the presence of an intermediate pre-test probability for asthma (diagnostic uncertainty), which is an infrequent setting. The most convenient exertional test is the 6-minute walk test that allows the assessment of walking performance, the search for arterial desaturation and the quantification of dyspnoea complaint. Copyright © 2015 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  1. Interaction between peri-operative blood transfusion, tidal volume, airway pressure and postoperative ARDS: an individual patient data meta-analysis.

    Science.gov (United States)

    Serpa Neto, Ary; Juffermans, Nicole P; Hemmes, Sabrine N T; Barbas, Carmen S V; Beiderlinden, Martin; Biehl, Michelle; Fernandez-Bustamante, Ana; Futier, Emmanuel; Gajic, Ognjen; Jaber, Samir; Kozian, Alf; Licker, Marc; Lin, Wen-Qian; Memtsoudis, Stavros G; Miranda, Dinis Reis; Moine, Pierre; Paparella, Domenico; Ranieri, Marco; Scavonetto, Federica; Schilling, Thomas; Selmo, Gabriele; Severgnini, Paolo; Sprung, Juraj; Sundar, Sugantha; Talmor, Daniel; Treschan, Tanja; Unzueta, Carmen; Weingarten, Toby N; Wolthuis, Esther K; Wrigge, Hermann; de Abreu, Marcelo Gama; Pelosi, Paolo; Schultz, Marcus J

    2018-01-01

    Transfusion of blood products and mechanical ventilation with injurious settings are considered risk factors for postoperative lung injury in surgical Patients. A systematic review and individual patient data meta-analysis was done to determine the independent effects of peri-operative transfusion of blood products, intra-operative tidal volume and airway pressure in adult patients undergoing mechanical ventilation for general surgery, as well as their interactions on the occurrence of postoperative acute respiratory distress syndrome (ARDS). Observational studies and randomized trials were identified by a systematic search of MEDLINE, CINAHL, Web of Science, and CENTRAL and screened for inclusion into a meta-analysis. Individual patient data were obtained from the corresponding authors. Patients were stratified according to whether they received transfusion in the peri-operative period [red blood cell concentrates (RBC) and/or fresh frozen plasma (FFP)], tidal volume size [≤7 mL/kg predicted body weight (PBW), 7-10 and >10 mL/kg PBW] and airway pressure level used during surgery (≤15, 15-20 and >20 cmH 2 O). The primary outcome was development of postoperative ARDS. Seventeen investigations were included (3,659 patients). Postoperative ARDS occurred in 40 (7.2%) patients who received at least one blood product compared to 40 patients (2.5%) who did not [adjusted hazard ratio (HR), 2.32; 95% confidence interval (CI), 1.25-4.33; P=0.008]. Incidence of postoperative ARDS was highest in patients ventilated with tidal volumes of >10 mL/kg PBW and having airway pressures of >20 cmH 2 O receiving both RBC and FFP, and lowest in patients ventilated with tidal volume of ≤7 mL/kg PBW and having airway pressures of ≤15 cmH 2 O with no transfusion. There was a significant interaction between transfusion and airway pressure level (P=0.002) on the risk of postoperative ARDS. Peri-operative transfusion of blood products is associated with an increased risk of

  2. Wake shed by an accelerating carangiform fish

    Science.gov (United States)

    Ting, Shang-Chieh; Yang, Jing-Tang

    2008-11-01

    We reveal an important fact that momentum change observed in the wake of an accelerating carangiform fish does not necessarily elucidate orientations of propulsive forces produced. An accelerating Crucian Carp (Carassius auratus) was found to shed a wake with net forward fluid momentum, which seemed drag-producing. Based on Newton's law, however, an accelerating fish is expected to shed a thrust wake with net rearward fluid momentum, rather than a drag wake. The unusual wake pattern observed is considered to be resulted primarily from the effect of pressure gradient created by accelerating movements of the fish. Ambient fluids tend to be sucked into low pressure zones behind an accelerating fish, resulting in forward orientations of jets recognizable in the wake. Accordingly, as to an accelerating fish, identifying force orientations from the wake requires considering also the effect of pressure gradient.

  3. CAD Instructor Designs Eco-Friendly Shed

    Science.gov (United States)

    Schwendau, Mark

    2013-01-01

    Dissatisfied with the options offered by big box stores--and wanting to save some money and go as green as possible--the author puts his design and construction skills to good use. In this article, he shares how he designed and built an eco-friendly shed. He says he is very pleased with the results of working with his own design, reducing waste,…

  4. Hjemløshed i Danmark 2011

    DEFF Research Database (Denmark)

    Lauritzen, Heidi Hesselberg; Boje-Kovacs, Bence; Benjaminsen, Lars

    Rapporten fremlægger resultaterne af den tredje nationale kortlægning af hjemløshed i Danmark og giver et ajourført billede af omfanget og karakteren af hjemløsheden. Ligesom i de to forrige optællinger blev der i kortlægningsugen (uge 6) registreret ca. 5.000 hjemløse. Sammensætningen af gruppen...

  5. Periodic cavitation shedding in a cylindrical orifice

    Energy Technology Data Exchange (ETDEWEB)

    Stanley, C.; Barber, T.; Milton, B.; Rosengarten, G. [University of New South Wales, School of Mechanical and Manufacturing Engineering, Sydney (Australia)

    2011-11-15

    Cavitation structures in a large-scale (D = 8.25 mm), plain orifice style nozzle within a unique experimental rig are investigated using high-speed visualisation and digital image processing techniques. Refractive index matching with an acrylic nozzle is achieved using aqueous sodium iodide for the test fluid. Cavitation collapse length, unsteady shedding frequency and spray angles are measured for cavitation conditions from incipient to supercavitation for a range of Reynolds numbers, for a fixed L/D ratio of 4.85. Periodic cavitation shedding was shown to occur with frequencies between 500 and 2,000 Hz for conditions in which cavitation occupied less than 30% of the nozzle length. A discontinuity in collapse length was shown to occur once the cavitation exceeded this length, coinciding with a loss of periodic shedding. A mechanism for this behaviour is discussed. Peak spray angles of approximately {theta} {approx} 14 were recorded for supercavitation conditions indicating the positive influence of cavitation bubble collapse on the jet atomisation process. (orig.)

  6. Subclinical herpesvirus shedding among HIV-1-infected men on antiretroviral therapy.

    Science.gov (United States)

    Agudelo-Hernandez, Arcadio; Chen, Yue; Bullotta, Arlene; Buchanan, William G; Klamar-Blain, Cynthia R; Borowski, Luann; Riddler, Sharon A; Rinaldo, Charles R; Macatangay, Bernard J C

    2017-09-24

    We evaluated the subclinical shedding of six different herpesviruses in antiretroviral drug-treated HIV-positive [HIV(+)] MSM, and determined how this is associated with markers of inflammation and immune activation. We obtained blood, semen, throat washing, urine, and stool from 15 antiretroviral-treated HIV-1-infected MSM with CD4 T-cell reconstitution, and 12 age-matched HIV-negative [HIV (-)] MSM from the Multicenter AIDS Cohort Study at four timepoints over 24 weeks to measure DNA levels of cytomegalovirus (CMV), Epstein-Barr virus (EBV), herpes simplex virus 1 and 2, human herpesvirus 6 (HHV6), and HHV8. T-cell activation and plasma levels of soluble markers of inflammation and activation were also measured at the corresponding timepoints. HIV(+) participants had a trend for higher total herpesvirus shedding rate. HIV(+) participants also had a significantly higher rate of shedding EBV and CMV compared with the HIV(-) group. Herpesvirus shedding was mostly seen in throat washings. In the HIV(+) group, herpesvirus shedding rate inversely correlated with plasma levels of interferon γ-induced protein 10 and soluble CD163. CMV DNA levels negatively correlated with levels of T-cell activation. There was a trend for a positive correlation between EBV shedding rate and plasma soluble CD14. HHV6 shedding rate negatively correlated with plasma levels of interleukin-6, soluble CD163, and interferon gamma-induced protein 10. Correlations were not observed among HIV(-) individuals. Among treated HIV-infected MSM, there are higher subclinical shedding rates of some herpesviruses that occur in different body compartments and negatively correlate with levels of inflammation and immune activation.

  7. Changes in plasma volume, in transcapillary escape rate of albumin and in subcutaneous blood flow during hypoglycaemia in man

    DEFF Research Database (Denmark)

    Hilsted, J; Bonde-Petersen, F; Madsbad, S

    1985-01-01

    and transcapillary escape rate increased significantly during hypoglycaemia. Skin temperature and local subcutaneous adipose tissue blood flow were measured in four different regions. Both tended to decrease during hypoglycaemia and decreased significantly 2 h after hypoglycaemia. There was no correlation between...... changes in the two measurements, suggesting that there is no simple relationship between subcutaneous blood flow and skin temperature during hypoglycaemia....

  8. Mean corpuscular volume of control red blood cells determines the interpretation of eosin-5'-maleimide (EMA) test result in infants aged less than 6 months.

    Science.gov (United States)

    Ciepiela, Olga; Adamowicz-Salach, Anna; Bystrzycka, Weronika; Łukasik, Jan; Kotuła, Iwona

    2015-08-01

    Eosin-5'-maleimide (EMA) binding test is a flow cytometric test used to detect hereditary spherocytosis (HS). To perform the test sample from patients, 5-6 reference samples of red blood are needed. Our aim was to investigate how the mean corpuscular volume (MCV) of red blood cells influences on the value of fluorescence of bounded EMA dye and how the choice of reference samples affects the test result. EMA test was performed in peripheral blood from 404 individuals, including 31 children suffering from HS. Mean fluorescence channel of EMA-RBCs was measured with Cytomics FC500 flow cytometer. Mean corpuscular volume of RBCs was assessed with LH750 Beckman Coulter. Statistical analysis was performed using Graph Pad Prism. The correlation Spearman coefficient between mean channel of fluorescence of EMA-RBCs and MCV was r = 0.39, p < 0.0001. Interpretation of EMA test depends on MCV of the reference samples. If reference blood samples have lower MCV than the patients MCV, EMA test result might be negative. Due to different MCV values of RBCs in infancy and ca. Three months later, EMA test in neonates might be interpreted falsely negative. Samples from children younger than 3 months old had EMA test result 86.1 ± 11.7 %, whereas same samples that analyzed 4.1 ± 2.1 later had results of 75.4 ± 4.5 %, p < 0.05. Mean fluorescence of EMA-bound RBC depends on RBC's volume. MCV of reference samples affects EMA test results; thus, we recommend selection of reference samples with MCV in range of ±2 fL compared to MCV of patient RBC's.

  9. Bovine coronavirus in naturally and experimentally exposed calves; viral shedding and the potential for transmission.

    Science.gov (United States)

    Oma, Veslemøy Sunniva; Tråvén, Madeleine; Alenius, Stefan; Myrmel, Mette; Stokstad, Maria

    2016-06-13

    Bovine coronavirus (BCoV) is a widely distributed pathogen, causing disease and economic losses in the cattle industry worldwide. Prevention of virus spread is impeded by a lack of basic knowledge concerning viral shedding and transmission potential in individual animals. The aims of the study were to investigate the duration and quantity of BCoV shedding in feces and nasal secretions related to clinical signs, the presence of virus in blood and tissues and to test the hypothesis that seropositive calves are not infectious to naïve in-contact calves three weeks after BCoV infection. A live animal experiment was conducted, with direct contact between animal groups for 24 h as challenge procedure. Four naïve calves were commingled with a group of six naturally infected calves and sequentially euthanized. Two naïve sentinel calves were commingled with the experimentally exposed group three weeks after exposure. Nasal swabs, feces, blood and tissue samples were analyzed for viral RNA by RT-qPCR, and virus isolation was performed on nasal swabs. Serum was analyzed for BCoV antibodies. The calves showed mild general signs, and the most prominent signs were from the respiratory system. The overall clinical score corresponded well with the shedding of viral RNA the first three weeks after challenge. General depression and cough were the signs that correlated best with shedding of BCoV RNA, while peak respiratory rate and peak rectal temperature appeared more than a week later than the peak shedding. Nasal shedding preceded fecal shedding, and the calves had detectable amounts of viral RNA intermittently in feces through day 35 and in nasal secretions through day 28, however virus isolation was unsuccessful from day six and day 18 from the two calves investigated. Viral RNA was not detected in blood, but was found in lymphatic tissue through day 42 after challenge. Although the calves were shedding BCoV RNA 21 days after infection the sentinel animals were not infected

  10. Visit-to-Visit Blood Pressure Variability in Young Adulthood and Hippocampal Volume and Integrity at Middle Age: The CARDIA Study (Coronary Artery Risk Development in Young Adults).

    Science.gov (United States)

    Yano, Yuichiro; Reis, Jared P; Levine, Deborah A; Bryan, R Nick; Viera, Anthony J; Shimbo, Daichi; Tedla, Yacob G; Allen, Norrina B; Schreiner, Pamela J; Bancks, Michael P; Sidney, Stephen; Pletcher, Mark J; Liu, Kiang; Greenland, Philip; Lloyd-Jones, Donald M; Launer, Lenore J

    2017-12-01

    The aims of this study are to assess the relationships of visit-to-visit blood pressure (BP) variability in young adulthood to hippocampal volume and integrity at middle age. We used data over 8 examinations spanning 25 years collected in the CARDIA study (Coronary Artery Risk Development in Young Adults) of black and white adults (age, 18-30 years) started in 1985 to 1986. Visit-to-visit BP variability was defined as by SD BP and average real variability (ARV BP , defined as the absolute differences of BP between successive BP measurements). Hippocampal tissue volume standardized by intracranial volume (%) and integrity assessed by fractional anisotropy were measured by 3-Tesla magnetic resonance imaging at the year-25 examination (n=545; mean age, 51 years; 54% women and 34% African Americans). Mean systolic BP (SBP)/diastolic BP levels were 110/69 mm Hg at year 0 (baseline), 117/73 mm Hg at year 25, and ARV SBP and SD SBP were 7.7 and 7.9 mm Hg, respectively. In multivariable-adjusted linear models, higher ARV SBP was associated with lower hippocampal volume (unstandardized regression coefficient [standard error] with 1-SD higher ARV SBP : -0.006 [0.003]), and higher SD SBP with lower hippocampal fractional anisotropy (-0.02 [0.01]; all P young adulthood may be useful in assessing the potential risk for reductions in hippocampal volume and integrity in midlife. © 2017 American Heart Association, Inc.

  11. Measurement of absolute myocardial blood flow with H215O and dynamic positron-emission tomography. Strategy for quantification in relation to the partial-volume effect

    International Nuclear Information System (INIS)

    Iida, H.; Kanno, I.; Takahashi, A.

    1988-01-01

    An in vivo technique was developed for measuring the absolute myocardial blood flow with H 2 15 O and dynamic positron-emission tomography. This technique was based on a new model involving the concept of the tissue fraction, which was defined as the fraction of the tissue mass in the volume of the region of interest. The myocardium was imaged dynamically by positron-emission tomography, starting at the time of intravenous bolus injection of H 2 15 O. The arterial input function was measured continuously with a beta-ray detector. A separate image after C 15 O inhalation was also obtained for correction of the H 2 15 O radioactivity in the blood. The absolute myocardial blood flow and the tissue fraction were calculated for 15 subjects with a kinetic technique under region-of-interest analysis. These results seem consistent with their coronary angiographic findings. The mean value of the measured absolute myocardial blood flows in normal subjects was 0.95 +/- 0.09 ml/min/g. This technique detected a diffuse decrease of myocardial blood flow in patients with triple-vessel disease

  12. Leading-edge vortex shedding from rotating wings

    Energy Technology Data Exchange (ETDEWEB)

    Kolomenskiy, Dmitry [Centre de Recherches Mathématiques (CRM), Department of Mathematics and Statistics, McGill University, 805 Sherbrooke W., Montreal, QC H3A 0B9 (Canada); Elimelech, Yossef [Faculty of Aerospace Engineering, Technion-Israel Institute of Technology, Haifa 32000 (Israel); Schneider, Kai, E-mail: dkolom@gmail.com [M2P2–CNRS, Université d' Aix-Marseille, 39, rue Frédéric Joliot-Curie, F-13453 Marseille Cedex 13 (France)

    2014-06-01

    This paper presents a numerical investigation of the leading-edge vortices generated by rotating triangular wings at Reynolds number Re = 250. A series of three-dimensional numerical simulations have been carried out using a Fourier pseudo-spectral method with volume penalization. The transition from stable attachment of the leading-edge vortex to periodic vortex shedding is explored, as a function of the wing aspect ratio and the angle of attack. It is found that, in a stable configuration, the spanwise flow in the recirculation bubble past the wing is due to the centrifugal force, incompressibility and viscous stresses. For the flow outside of the bubble, an inviscid model of spanwise flow is presented. (papers)

  13. Iodine status and its correlations with age, blood pressure, and thyroid volume in South Indian women above 35 years of age (Amrita Thyroid Survey

    Directory of Open Access Journals (Sweden)

    Vadayath Usha Menon

    2011-01-01

    Full Text Available Background: Thyroid disorders are more commonly seen among females and the prevalence increases with age. There is no population data from India focusing on iodine levels and their correlations with thyroid volume and other factors in adult women. Aim: This study was designed to establish the iodine status and its relation with various factors including thyroid volume measured by ultrasound among the females of Kerala. Materials and Methods: This was a cross sectional house to house survey among the females above 35 years of age in a randomly selected urban area in Cochin Corporation, Kerala State, India. Selected subjects were interviewed, examined and blood and urine tests were done. Thyroid volume was calculated using ultrasound. Results: Among the 508 subjects who participated in the checkup, 471 subjects were included for analysis. Mean age was 50.3 + 10.7 years and 53.2% were postmenopausal. A total of 98% of the subjects were using iodized salt and median urinary iodine excretion (UIE was 162.6 mcg/l. UIE had negative correlation with age and systolic blood pressure (BP, but had no correlation with thyroid volume (TV, thyroid nodularity, free thyroxine 4 (FT4, thyroid stimulating hormone (TSH or anti thyroid peroxidase (TPO levels. Iodine deficiency was more commonly seen in subjects with hypertension and also among postmenopausal females. Conclusions: This study showed that females > 35 years were iodine sufficient, though one third of the subjects had UIE levels less than the recommended level. Iodine levels had significant negative correlation with age and systolic BP and no correlation with thyroid volume or biochemical parameters. Iodine deficiency was significantly higher in subjects with new and known hypertension and this relation merits further evaluation.

  14. The effect of endogenously released glucose, insulin, glucagon-like peptide 1, ghrelin on cardiac output, heart rate, stroke volume, and blood pressure.

    Science.gov (United States)

    Hlebowicz, Joanna; Lindstedt, Sandra; Björgell, Ola; Dencker, Magnus

    2011-12-29

    Ingestion of a meal increases the blood flow to the gastrointestinal organs and affects the heart rate (HR), blood pressure and cardiac output (CO), although the mechanisms are not known. The aim of this study was to evaluate the effect of endogenously released glucose, insulin, glucagon-like peptide 1 (GLP-1), ghrelin on CO, HR, stroke volume (SV), and blood pressure. Eleven healthy men and twelve healthy women ((mean ± SEM) aged: 26 ± 0.2 y; body mass index: 21.8 ± 0.1 kg/m(2))) were included in this study. The CO, HR, SV, systolic and diastolic blood pressure, antral area, gastric emptying rate, and glucose, insulin, GLP-1 and ghrelin levels were measured. The CO and SV at 30 min were significantly higher, and the diastolic blood pressure was significantly lower, than the fasting in both men and women (P blood pressure (P = 0.021, r = -0.681), and the change in SV (P = 0.008, r = -0.748) relative to the fasting in men. The insulin 0-30 min AUC was significantly correlated to the CO 0-30 min AUC (P = 0.002, r = 0.814) in men. Significant correlations were also found between the 0-120 min ghrelin and HR AUCs (P = 0.007, r = 0.966) in men. No statistically significant correlations were seen in women. Physiological changes in the levels of glucose, insulin, GLP-1 and ghrelin may influence the activity of the heart and the blood pressure. There may also be gender-related differences in the haemodynamic responses to postprandial changes in hormone levels. The results of this study show that subjects should not eat immediately prior to, or during, the evaluation of cardiovascular interventions as postprandial affects may affect the results, leading to erroneous interpretation of the cardiovascular effects of the primary intervention. NCT01027507.

  15. Novel system using microliter order sample volume for measuring arterial radioactivity concentrations in whole blood and plasma for mouse PET dynamic study.

    Science.gov (United States)

    Kimura, Yuichi; Seki, Chie; Hashizume, Nobuya; Yamada, Takashi; Wakizaka, Hidekatsu; Nishimoto, Takahiro; Hatano, Kentaro; Kitamura, Keishi; Toyama, Hiroshi; Kanno, Iwao

    2013-11-21

    This study aimed to develop a new system, named CD-Well, for mouse PET dynamic study. CD-Well allows the determination of time-activity curves (TACs) for arterial whole blood and plasma using 2-3 µL of blood per sample; the minute sample size is ideal for studies in small animals. The system has the following merits: (1) measures volume and radioactivity of whole blood and plasma separately; (2) allows measurements at 10 s intervals to capture initial rapid changes in the TAC; and (3) is compact and easy to handle, minimizes blood loss from sampling, and delay and dispersion of the TAC. CD-Well has 36 U-shaped channels. A drop of blood is sampled into the opening of the channel and stored there. After serial sampling is completed, CD-Well is centrifuged and scanned using a flatbed scanner to define the regions of plasma and blood cells. The length measured is converted to volume because the channels have a precise and uniform cross section. Then, CD-Well is exposed to an imaging plate to measure radioactivity. Finally, radioactivity concentrations are computed. We evaluated the performance of CD-Well in in vitro measurement and in vivo (18)F-fluorodeoxyglucose and [(11)C]2-carbomethoxy-3β-(4-fluorophenyl) tropane studies. In in vitro evaluation, per cent differences (mean±SE) from manual measurement were 4.4±3.6% for whole blood and 4.0±3.5% for plasma across the typical range of radioactivity measured in mouse dynamic study. In in vivo studies, reasonable TACs were obtained. The peaks were captured well, and the time courses coincided well with the TAC derived from PET imaging of the heart chamber. The total blood loss was less than 200 µL, which had no physiological effect on the mice. CD-Well demonstrates satisfactory performance, and is useful for mouse PET dynamic study.

  16. Simultaneous assessment of cerebral blood volume and diffusion heterogeneity using hybrid IVIM and DK MR imaging: initial experience with brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Wen-Chau [National Taiwan University, Graduate Institute of Oncology, Taipei (China); National Taiwan University, Graduate Institute of Clinical Medicine, Taipei (China); National Taiwan University, Graduate Institute of Biomedical Electronics and Bioinformatics, Taipei (China); National Taiwan University Hospital, Department of Medical Imaging, Taipei (China); Yang, Shun-Chung; Chen, Ya-Fang; My, Pei-Chi [National Taiwan University Hospital, Department of Medical Imaging, Taipei (China); Tseng, Han-Min [National Taiwan University Hospital, Department of Neurology, Taipei (China)

    2017-01-15

    To investigate the feasibility of simultaneously assessing cerebral blood volume and diffusion heterogeneity using hybrid diffusion-kurtosis (DK) and intravoxel-incoherent-motion (IVIM) MR imaging. Fifteen healthy volunteers and 30 patients with histologically proven brain tumours (25 WHO grade II-IV gliomas and five metastases) were recruited. On a 3-T system, diffusion-weighted imaging was performed with six b-values ranging from 0 to 1,700 s/mm{sup 2}. Nonlinear least-squares fitting was employed to extract diffusion coefficient (D), diffusion kurtosis coefficient (K, a measure of the degree of non-Gaussian and heterogeneous diffusion) and intravascular volume fraction (f, a measure proportional to cerebral blood volume). Repeated-measures multivariate analysis of variance and receiver operating characteristic analysis were performed to assess the ability of D/K/f in differentiating contrast-enhanced tumour from peritumoral oedema and normal-appearing white matter. Based on our imaging setting (baseline signal-to-noise ratio = 32-128), coefficient of variation was 14-20 % for K, ∝6 % for D and 26-44 % for f. The indexes were able to differentiate contrast-enhanced tumour (Wilks' λ = 0.026, p < 10{sup -3}), and performance was greatest with K, followed by f and D. Hybrid DK IVIM imaging is capable of simultaneously measuring cerebral perfusion and diffusion indexes that together may improve brain tumour diagnosis. (orig.)

  17. Dual energy CT pulmonary blood volume assessment in acute pulmonary embolism - correlation with D-dimer level, right heart strain and clinical outcome

    International Nuclear Information System (INIS)

    Bauer, Ralf W.; Frellesen, Claudia; Schell, Boris; Lehnert, Thomas; Jacobi, Volkmar; Vogl, Thomas J.; Kerl, J.M.; Renker, Matthias; Ackermann, Hanns; Schoepf, U.J.

    2011-01-01

    To investigate the role of perfusion defect (PD) size on dual energy CT pulmonary blood volume assessment as predictor of right heart strain and patient outcome and its correlation with d-dimer levels in acute pulmonary embolism (PE). 53 patients with acute PE who underwent DECT pulmonary angiography were retrospectively analyzed. Pulmonary PD size caused by PE was measured on DE iodine maps and quantified absolutely (VolPD) and relatively to the total lung volume (RelPD). Signs of right heart strain (RHS) on CT were determined. Information on d-dimer levels and readmission for recurrent onset of PE and death was collected. D-dimer level was mildly (r = 0.43-0.47) correlated with PD size. Patients with RHS had significantly higher VolPD (215 vs. 73 ml) and RelPD (9.9 vs. 2.9%) than patients without RHS (p 5% RelPD, while no such events were found for patients with <5% RelPD. Pulmonary blood volume on DECT in acute PE correlates with RHS and appears to be a predictor of patient outcome in this pilot study. (orig.)

  18. Dual energy CT pulmonary blood volume assessment in acute pulmonary embolism - correlation with D-dimer level, right heart strain and clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, Ralf W.; Frellesen, Claudia; Schell, Boris; Lehnert, Thomas; Jacobi, Volkmar; Vogl, Thomas J.; Kerl, J.M. [Clinic of the Goethe University, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Renker, Matthias [Clinic of the Goethe University, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Medical University of South Carolina, Heart and Vascular Center, Ashley River Tower, Charleston, SC (United States); Ackermann, Hanns [Clinic of the Goethe University, Department of Biostatistics and Mathematical Modelling, Frankfurt (Germany); Schoepf, U.J. [Medical University of South Carolina, Heart and Vascular Center, Ashley River Tower, Charleston, SC (United States)

    2011-09-15

    To investigate the role of perfusion defect (PD) size on dual energy CT pulmonary blood volume assessment as predictor of right heart strain and patient outcome and its correlation with d-dimer levels in acute pulmonary embolism (PE). 53 patients with acute PE who underwent DECT pulmonary angiography were retrospectively analyzed. Pulmonary PD size caused by PE was measured on DE iodine maps and quantified absolutely (VolPD) and relatively to the total lung volume (RelPD). Signs of right heart strain (RHS) on CT were determined. Information on d-dimer levels and readmission for recurrent onset of PE and death was collected. D-dimer level was mildly (r = 0.43-0.47) correlated with PD size. Patients with RHS had significantly higher VolPD (215 vs. 73 ml) and RelPD (9.9 vs. 2.9%) than patients without RHS (p < 0.003). There were 2 deaths and 1 readmission due of PE in 18 patients with >5% RelPD, while no such events were found for patients with <5% RelPD. Pulmonary blood volume on DECT in acute PE correlates with RHS and appears to be a predictor of patient outcome in this pilot study. (orig.)

  19. Noninvasive, low-noise, fast imaging of blood volume and deoxygenation changes in muscles using light-emitting diode continuous-wave imager

    Science.gov (United States)

    Lin, Yuanqing; Lech, Gwen; Nioka, Shoko; Intes, Xavier; Chance, Britton

    2002-08-01

    This article focuses on optimizing the signal to noise ratio (SNR) of a three-wavelength light-emitting diode (LED) near-infrared continuous-wave (cw) imager and its application to in vivo muscle metabolism measurement. The shot-noise limited SNR is derived and calculated to be 2 x104 for the physiological blood concentrations of muscle. Aiming at shot-noise limited SNR performance and fast imaging, we utilize sample and hold circuits to reduce high-frequency noise. These circuits have also been designed to be parallel integrating, through which SNR of 2 x103 and 2 Hz imaging acquisition rate have been achieved when the probe is placed on a muscle model. The noise corresponds to 2 x10-4 optical density error, which suggests an in vitro resolution of 15. 4 nM blood volume and 46.8 nM deoxygenation changes. A 48 dB digital gain control circuit with 256 steps is employed to enlarge the dynamic range of the imager. We utilize cuff ischemia as a living model demonstration and its results are reported. The instrument is applied during exercise to measure the changes of blood volume and deoxygenation, which provides important information about muscle metabolism. We find that the primary source of noise encountered during exercise experiment is from the random motion of muscle. The results demonstrate that the LED cw imager is ideal for the noninvasive study of muscle metabolism.

  20. Information content in spectral dependencies of optical unit volume parameters under action of He-Ne laser on blood

    Science.gov (United States)

    Khairullina, Alphiya Y.; Oleinik, Tatiana V.

    1995-01-01

    Our previous works concerned with the development of methods for studying blood and action of low-intensity laser radiation on blood and erythrocyte suspensions had shown the light- scattering methods gave a large body of information on a medium studied due to the methodological relationship between irradiation processes and techniques for investigations. Detail analysis of spectral diffuse reflectivities and transmissivities of optically thick blood layers, spectral absorptivities calculated on this basis over 600 - 900 nm, by using different approximations, for a pathological state owing to hypoxia testifies to the optical significance of not only hemoglobin derivatives but also products of hemoglobin decomposition. Laser action on blood is specific and related to an initial state of blood absorption due to different composition of chromoproteids. This work gives the interpretation of spectral observations. Analysis of spectral dependencies of the exinction coefficient e, mean cosine m of phase function, and parameter Q equals (epsilon) (1-(mu) )H/(lambda) (H - hematocrit) testifies to decreasing the relative index of refraction of erythrocytes and to morphological changes during laser action under pathology owing to hypoxia. The possibility to obtain physical and chemical information on the state of blood under laser action in vivo is shown to be based on the method proposed by us for calculating multilayered structures modeling human organs and on the technical implementation of this method.

  1. Suppression of vortex shedding around a square cylinder using ...

    Indian Academy of Sciences (India)

    control of vortex shedding of square cylinders using blowing or suction. ... also showed complete suppression of vortex shedding if suction velocity falls between 0.40 .... equations such that mass balance (continuity) is satisfied simultaneously.

  2. Lysozyme and bilirubin bind to ACE and regulate its conformation and shedding

    Science.gov (United States)

    Danilov, Sergei M.; Lünsdorf, Heinrich; Akinbi, Henry T.; Nesterovitch, Andrew B.; Epshtein, Yuliya; Letsiou, Eleftheria; Kryukova, Olga V.; Piegeler, Tobias; Golukhova, Elena Z.; Schwartz, David E.; Dull, Randal O.; Minshall, Richard D.; Kost, Olga A.; Garcia, Joe G. N.

    2016-01-01

    Angiotensin I-converting enzyme (ACE) hydrolyzes numerous peptides and is a critical participant in blood pressure regulation and vascular remodeling. Elevated tissue ACE levels are associated with increased risk for cardiovascular and respiratory disorders. Blood ACE concentrations are determined by proteolytic cleavage of ACE from the endothelial cell surface, a process that remains incompletely understood. In this study, we identified a novel ACE gene mutation (Arg532Trp substitution in the N domain of somatic ACE) that increases blood ACE activity 7-fold and interrogated the mechanism by which this mutation significantly increases blood ACE levels. We hypothesized that this ACE mutation disrupts the binding site for blood components which may stabilize ACE conformation and diminish ACE shedding. We identified the ACE-binding protein in the blood as lysozyme and also a Low Molecular Weight (LMW) ACE effector, bilirubin, which act in concert to regulate ACE conformation and thereby influence ACE shedding. These results provide mechanistic insight into the elevated blood level of ACE observed in patients on ACE inhibitor therapy and elevated blood lysozyme and ACE levels in sarcoidosis patients. PMID:27734897

  3. The Effect of Radioactive Lantern Mantle Powder and Bentonite-Zeoloite Minerals on the Volume of Blood Loss, Bleeding and Clotting Time

    Directory of Open Access Journals (Sweden)

    M Atefi

    2009-04-01

    Full Text Available ABSTRACT Introduction & Objective: Over the past decade the US army has widely studied new technologies for stopping sever hemorrhages and has introduced an effective Zeolite based hemostatic agent. On the other hand, Mortazavi and his colleagues previously reported the bio-stimulatory effects of the topical application of radioactive lantern mantle powder on wound healing. Their subsequent studies showed significant changes in some histological parameters concerning healing. In this light, here the bio-stimulatory effect of burned radioactive lantern mantles powder as well as two minerals bentonite and zeolite are presented. Materials & Methods: This experimental study was conducted in the center for radiological studies, Shiraz University of Medical Sciences in 2008. Fifty male Wistar rats were divided randomly into 5 groups of 10 animals each. Following anesthesia, animals’ tails were cut at a thickness of 5 mm by using a surgical scissor. No intervention was made on the animals of the 1st group. The 2nd to 4th group received topical non-radioactive lantern mantle powder, radioactive lantern mantle powder, Bentonite mineral or a mixture of Bentonite-Zeoliteat minerals respectively. After treatment with above mentioned agents, the volume of blood loss was measured using a scaled test-tube. The bleeding time and clotting time were also measured using a chronometer. SPSS software was used for statistical analysis. ANOVA was used for comparing the means of each parameter in the 5 groups. Results: The the volume of blood loss, bleeding and clotting times in control animals were 4.39±1.92 cc, 112.10±39.60 sec and 94.9±54.26 sec, respectively. In the 5th group in which the animals were treated with a mixture of Bentonite-Zeoliteat minerals, the volume of blood loss, bleeding and clotting times were 1.31±0.60 cc, 34.50±4.65 sec and 24.2±4.61 sec, respectively. Conclusion: This is the 1st investigation that studied the alterations of bleeding

  4. Epicardial adipose tissue volume a diagnostic study for independent predicting disorder of circadian rhythm of blood pressure in patients with essential hypertension.

    Science.gov (United States)

    Zhou, L; Deng, Y; Gong, J; Chen, X; Zhang, Q; Wang, J

    2016-05-30

    The aim of the study was to determine whether epicardial adipose tissue volume (EATV), a new cardiometabolic risk factor, is associated with circadian changes of blood pressure (BP) in patients with newly diagnosed essential hypertension. Ninety patients with newly diagnosed essential hypertension underwent ambulatory blood pressure monitoring for 24 h. EATV was measured using cardiac computed tomography. These patients were categorized into three groups according to their BP patterns (group 1, n=46, dipper hypertension, also called normal pattern; group 2, n=24, non-dipper hypertension; group 3, n=20, anti-dipper hypertension; group 2 and 3 are also called abnormal pattern). Data were collected retrospectively and compared between hypertensive patients with normal pattern and abnormal pattern. The normal pattern hypertensive patient had significant lower mean EATV and BP ((EATV, 91.3±29.4 cm3) than those of abnormal pattern patients including group 2 (EATV, 116.2±31.06cm3, EATV, 124.8±28.5cm3, PEATV with abnormal blood pressure mode was 0.500 (pEATV was elevated in newly diagnosed and untreated patients with non-dipper hypertension and anti-dipper hypertension. EATV measured by cardiac computed tomography can be used to indicate the increased risk of circadian rhythm of blood pressure.

  5. EFFECTS OF A BASKETBALL ACTIVITY ON LUNG CAPILLARY BLOOD VOLUME AND MEMBRANE DIFFUSING CAPACITY, MEASURED BY NO/CO TRANSFER IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Rim Dridi

    2006-09-01

    Full Text Available In both children and adults, acute exercise increases lung capillary blood volume (Vc and membrane factor (DmCO. We sought to determine whether basketball training affected this adaptation to exercise in children. The purpose of this study was to determine the effects of two years sport activity on the components of pulmonary gas transfer in children. Over a 2-yr period, we retested 60 nine year old boys who were initially separated in two groups: 30 basketball players (P (9.0 ± 1.0 yrs; 35.0 ± 5.2 kg; 1.43 ± 0.05 m, and matched non players controls (C (8.9 ± 1.0 yrs; 35.0 ± 6.0 kg; 1.44 ± 0.06 m who did not perform any extracurricular activity, Vc and DmCO were measured by the NO/CO transfer method at rest and during sub-maximal exercise. Maximal aerobic power and peak power output was 12% higher in the trained group compared to matched controls (p < 0.05. Nitric oxide lung transfer (TLNO per unit lung volume and thus, DmCO per unit of lung volume (VA were higher at rest and during exercise in the group which had undergone regular basketball activity compared to matched controls (p < 0.05. Neither lung capillary blood volume nor total lung transfer for carbon monoxide (TLCO were significantly different between groups. These results suggest that active sport can alter the properties of the lung alveolo-capillary membrane by improving alveolar membrane conductance in children

  6. Avian bornavirus in free-ranging waterfowl: prevalence of antibodies and cloacal shedding of viral RNA.

    Science.gov (United States)

    Delnatte, Pauline; Nagy, Éva; Ojkic, Davor; Leishman, David; Crawshaw, Graham; Elias, Kyle; Smith, Dale A

    2014-07-01

    We surveyed free-ranging Canada Geese (Branta canadensis), Trumpeter Swans (Cygnus buccinator), Mute Swans (Cygnus olor), and Mallards (Anas platyrhynchos) to estimate the prevalence of antibodies to avian bornavirus (ABV) and of cloacal shedding of ABV RNA in southern Ontario, Canada. Blood samples and cloacal swabs were collected from 206 free-ranging Canada Geese, 135 Trumpeter Swans, 75 Mute Swans, and 208 Mallards at 10 main capture sites between October 2010 and May 2012. Sera were assessed for antibodies against ABV by enzyme-linked immunosorbent assay and swabs were evaluated for ABV RNA using real-time reverse-transcription PCR. Serum antibodies were detected in birds from all four species and at each sampling site. Thirteen percent of the geese caught on the Toronto Zoo site shed ABV RNA in feces compared with 0% in geese sampled at three other locations. The proportions of shedders among Mute Swans, Trumpeter Swans, and Mallards were 9%, 0%, and 0%, respectively. Birds that were shedding viral RNA were more likely to have antibodies against ABV and to have higher antibody levels than those that were not, although many birds with antibodies were not shedding. We confirmed that exposure to, or infection with, ABV is widespread in asymptomatic free-ranging waterfowl in Canada; however, the correlation between cloacal shedding, presence of antibodies, and presence of disease is not fully understood.

  7. Shedding and serological patterns of dairy cows following abortions associated with Coxiella burnetii DNA detection.

    Science.gov (United States)

    Guatteo, R; Joly, A; Beaudeau, F

    2012-03-23

    To describe both shedding and serological patterns following abortions detected as being associated with Coxiella burnetii (Cb), 24 cows experiencing an abortion due to Cb were followed over a one month period. Samples taken on the day of abortion (D0) were followed 3-fold by weekly samplings from day 14 (D14) to D28 after the abortion. Milk and vaginal mucus were collected at each weekly sampling and tested using real-time PCR while blood samples were collected 2-fold on D21 and D28 and tested using ELISA. We found a very short duration of C. burnetii shedding in vaginal mucus after abortion, highlighting the need to collect samples as rapidly as possible following an abortion to avoid false negative results. In contrast with previous results, concomitancy of vaginal and mucus shedding was frequent, especially for cows shedding a high bacterial load on DO leading to the hypothesis that the clinical onset of the infection influences the modalities of Cb shedding. Lastly, serological results indicating a lack of sensitivity to detect Cb shedder cows (especially for cows for which Ct values were high) suggest that ELISA is not a useful tool to diagnose abortions at the individual level. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Whole-tumor histogram analysis of the cerebral blood volume map: tumor volume defined by 11C-methionine positron emission tomography image improves the diagnostic accuracy of cerebral glioma grading.

    Science.gov (United States)

    Wu, Rongli; Watanabe, Yoshiyuki; Arisawa, Atsuko; Takahashi, Hiroto; Tanaka, Hisashi; Fujimoto, Yasunori; Watabe, Tadashi; Isohashi, Kayako; Hatazawa, Jun; Tomiyama, Noriyuki

    2017-10-01

    This study aimed to compare the tumor volume definition using conventional magnetic resonance (MR) and 11C-methionine positron emission tomography (MET/PET) images in the differentiation of the pre-operative glioma grade by using whole-tumor histogram analysis of normalized cerebral blood volume (nCBV) maps. Thirty-four patients with histopathologically proven primary brain low-grade gliomas (n = 15) and high-grade gliomas (n = 19) underwent pre-operative or pre-biopsy MET/PET, fluid-attenuated inversion recovery, dynamic susceptibility contrast perfusion-weighted magnetic resonance imaging, and contrast-enhanced T1-weighted at 3.0 T. The histogram distribution derived from the nCBV maps was obtained by co-registering the whole tumor volume delineated on conventional MR or MET/PET images, and eight histogram parameters were assessed. The mean nCBV value had the highest AUC value (0.906) based on MET/PET images. Diagnostic accuracy significantly improved when the tumor volume was measured from MET/PET images compared with conventional MR images for the parameters of mean, 50th, and 75th percentile nCBV value (p = 0.0246, 0.0223, and 0.0150, respectively). Whole-tumor histogram analysis of CBV map provides more valuable histogram parameters and increases diagnostic accuracy in the differentiation of pre-operative cerebral gliomas when the tumor volume is derived from MET/PET images.

  9. 76 FR 66220 - Automatic Underfrequency Load Shedding and Load Shedding Plans Reliability Standards

    Science.gov (United States)

    2011-10-26

    .... I. Background A. Underfrequency Load Shedding 4. An interconnected electric power system must... generation and load within an interconnected electric power system is shown in the frequency of the system.\\4... Reliability Standards for the Bulk-Power System, Order No. 693, FERC Stats. & Regs. ] 31,242, order on reh'g...

  10. Factors affecting autologous peripheral blood hematopoietic stem cell collections by large-volume leukapheresis: a single center experience

    Directory of Open Access Journals (Sweden)

    Araci Massami Sakashita

    2011-06-01

    Full Text Available Objective: To evaluate factors affecting peripheral bloodhematopoietic stem cell yield in patients undergoing large-volumeleukapheresis for autologous peripheral blood stem cell collection.Methods: Data from 304 consecutive autologous peripheral bloodstem cell donors mobilized with hematopoietic growth factor (usually G-CSF, associated or not with chemotherapy, at Hospital Israelita Albert Einstein between February 1999 and June 2010 were retrospectively analyzed. The objective was to obtain at least 2 x 106CD34+ cells/kg of body weight. Pre-mobilization factors analyzedincluded patient’s age, gender and diagnosis. Post mobilizationparameters evaluated were pre-apheresis peripheral white bloodcell count, immature circulating cell count, mononuclear cell count,peripheral blood CD34+ cell count, platelet count, and hemoglobinlevel. The effect of pre and post-mobilization factors on hematopoietic stem cell collection yield was investigated using logistic regression analysis (univariate and multivariate approaches. Results: Premobilization factors correlating to poor CD34+ cell yield in univariate analysis were acute myeloid leukemia (p = 0.017 and other hematological diseases (p = 0.023. Significant post-mobilization factors included peripheral blood immature circulating cells (p = 0.001, granulocytes (p = 0.002, hemoglobin level (p = 0.016, and CD34+ cell concentration (p < 0.001 in the first harvesting day. However, according to multivariate analysis, peripheral blood CD34+ cell content (p < 0.001 was the only independent factor that significantly correlated to poor hematopoietic stem cell yield. Conclusion: In this study, peripheral blood CD34+ cell concentration was the only factor significantly correlated to yield in patients submitted to for autologous collection.

  11. HIV shedding in cervico-vaginal secretions in pregnant women.

    Science.gov (United States)

    Gardella, Barbara; Roccio, Marianna; Maccabruni, Anna; Mariani, Bianca; Panzeri, Lucia; Zara, Francesca; Spinillo, Arsenio

    2011-07-01

    The purpose of this study was to evaluate the presence of HIV-1 in cervico-vaginal secretions of pregnant as compared to non-pregnant HIV-seropositive women. We compared 43 known HIV seropositive pregnant patients versus 241 age-matched (± 2 years) control non-pregnant HIV-seropositive subjects. In pregnant patients blood and cervico-vaginal samples were obtained during each trimester of pregnancy. In control subjects the same samples were obtained at enrolment. HIV-1 RNA was measured in plasma; proviral HIV-1 DNA, cell-associated and cell-free HIV-1 RNA in cervico-vaginal secretion by competitive polymerase chain reaction (cRT-PCR) and reverse transcriptase PCR. The genital shedding of HIV-DNA (22/43 as compared to 79/241, p = 0.02), and cell-free HIV-RNA detection (26/43 as compared to 72/241, p pregnant than in non pregnant women. Pregnancy correlated with a significant positive trend in the cervico-vaginal load of HIV-DNA (Spearman Rho= 0.149, p= 0.012), and cell-free HIV-RNA (Spearman Rho= 0.253, p HIV-RNA transcripts (Spearman Rho = 0.06, p= 0.31). After correction for potential confounders, first trimester pregnant women had increased rates of genital HIV- DNA (odds ratio = 1.94, 95% confidence interval = 1.01 3.78) and cell-free HIV-RNA (odds ratio = 4.07, 95% confidence interval = 1.97 8.41) detection compared to nonpregnant controls. The shedding of genital HIV was increased in pregnant compared to non pregnant subjects, even in patients with undetectable viremia. In this low-risk HIV-positive population the risks of vertical or horizontal transmissions should not be underestimated.

  12. Validation of a blood marker for plasma volume in endurance athletes during a live-high train-low altitude training camp.

    Science.gov (United States)

    Lobigs, Louisa M; Garvican-Lewis, Laura A; Vuong, Victor L; Tee, Nicolin; Gore, Christopher J; Peeling, Peter; Dawson, Brian; Schumacher, Yorck O

    2018-02-19

    Altitude is a confounding factor within the Athlete Biological Passport (ABP) due, in part, to the plasma volume (PV) response to hypoxia. Here, a newly developed PV blood test is applied to assess the possible efficacy of reducing the influence of PV on the volumetric ABP markers; haemoglobin concentration ([Hb]) and the OFF-score. Endurance athletes (n=34) completed a 21-night simulated live-high train-low (LHTL) protocol (14 h.d -1 at 3000 m). Bloods were collected twice pre-altitude; at days 3, 8, and 15 at altitude; and 1, 7, 21, and 42 days post-altitude. A full blood count was performed on the whole blood sample. Serum was analysed for transferrin, albumin, calcium, creatinine, total protein, and low-density lipoprotein. The PV blood test (consisting of the serum markers, [Hb] and platelets) was applied to the ABP adaptive model and new reference predictions were calculated for [Hb] and the OFF-score, thereby reducing the PV variance component. The PV correction refined the ABP reference predictions. The number of atypical passport findings (ATPFs) for [Hb] was reduced from 7 of 5 subjects to 6 of 3 subjects. The OFF-score ATPFs increased with the PV correction (from 9 to 13, 99% specificity); most likely the result of more specific reference limit predictions combined with the altitude-induced increase in red cell production. Importantly, all abnormal biomarker values were identified by a low confidence value. Although the multifaceted, individual physiological response to altitude confounded some results, the PV model appears capable of reducing the impact of PV fluctuations on [Hb]. Copyright © 2018 John Wiley & Sons, Ltd.

  13. A randomized, controlled, double-blind crossover study on the effects of 1-L infusions of 6% hydroxyethyl starch suspended in 0.9% saline (voluven) and a balanced solution (Plasma Volume Redibag) on blood volume, renal blood flow velocity, and renal cortical tissue perfusion in healthy volunteers.

    Science.gov (United States)

    Chowdhury, Abeed H; Cox, Eleanor F; Francis, Susan T; Lobo, Dileep N

    2014-05-01

    We compared the effects of intravenous administration of 6% hydroxyethyl starch (maize-derived) in 0.9% saline (Voluven; Fresenius Kabi, Runcorn, United Kingdom) and a "balanced" preparation of 6% hydroxyethyl starch (potato-derived) [Plasma Volume Redibag (PVR); Baxter Healthcare, Thetford, United Kingdom] on renal blood flow velocity and renal cortical tissue perfusion in humans using magnetic resonance imaging. Hyperchloremia resulting from 0.9% saline infusion may adversely affect renal hemodynamics when compared with balanced crystalloids. This phenomenon has not been studied with colloids. Twelve healthy adult male subjects received 1-L intravenous infusions of Voluven or PVR over 30 minutes in a randomized, double-blind manner, with crossover studies 7 to 10 days later. Magnetic resonance imaging proceeded for 60 minutes after commencement of infusion to measure renal artery blood flow velocity and renal cortical perfusion. Blood was sampled, and weight was recorded at 0, 30, 60, 120, 180, and 240 minutes. Mean peak serum chloride concentrations were 108 and 106 mmol/L, respectively, after Voluven and PVR infusion (P = 0.032). Changes in blood volume (P = 0.867), strong ion difference (P = 0.219), and mean renal artery flow velocity (P = 0.319) were similar. However, there was a significant increase in mean renal cortical tissue perfusion after PVR when compared with Voluven (P = 0.033). There was no difference in urinary neutrophil gelatinase-associated liopcalin to creatinine ratios after the infusion (P = 0.164). There was no difference in the blood volume-expanding properties of the 2 preparations of 6% hydroxyethyl starch. The balanced starch produced an increase in renal cortical tissue perfusion, a phenomenon not seen with starch in 0.9% saline.

  14. Simultaneous estimations of blood brain barrier (BBB) permeability and local cerebral blood volume (CBV) in human brain tumors with positron tomography and Ga-68 EDTA

    International Nuclear Information System (INIS)

    Hawkins, R.A.; Phelps, M.E.; Huang, S.C.; Wapenski, J.A.; Grimm, P.D.; Greenberg, P.; Parker, R.G.; Juillard, G.; Kuhl, D.E.

    1984-01-01

    Using Ga-68 EDTA and a two compartment model for diffusion across the BBB that includes a weighted subtraction term for determination of the relative CBV (compared to a normal region of brain with an intact BBB) or the absolute value of CBV (using measurements of Ga-68 concentrations in the blood: the input function), the authors determined values for the forward and reverse rate constants (k1 and k2) for diffusion across the BBB as well as values of CBV in 12 subjects with primary or metastatic brain tumors. Patients were studied on a NeuroECAT tomograph; imaging times were 1 to 10 minutes per scan for a total of about 2 hours. Measurements of Ga-68 concentrations were made on plasma arterial samples. Four direct measurements (in 3 subjects) of CBV using C(15-0) were also obtained. Values of k1 (the transfer constant which numerically approximates the capillary permeability surface area (PS) product) averaged 0.0030 (+- 0.0017) ml/min/gm while k2 averaged 0.0308 (+- 0.0157)/min. Linear regression analysis of the relative CBV in 7 tumor deposits in 4 paired Ga-68 EDTA/C(15-0) studies compared to normal brain tissues resulted in a correlation coefficient of 0.97 for the two methods. The estimates of k1 and k2 were insensitive to changes in the location of the control regions (although CBV estimates changed appropriately) as well as to substituting the input function for a normal brain region when determining the absolute CBV of the lesions

  15. Simultaneous assessment of cerebral blood volume and diffusion heterogeneity using hybrid IVIM and DK MR imaging: initial experience with brain tumors.

    Science.gov (United States)

    Wu, Wen-Chau; Yang, Shun-Chung; Chen, Ya-Fang; Tseng, Han-Min; My, Pei-Chi

    2017-01-01

    To investigate the feasibility of simultaneously assessing cerebral blood volume and diffusion heterogeneity using hybrid diffusion-kurtosis (DK) and intravoxel-incoherent-motion (IVIM) MR imaging. Fifteen healthy volunteers and 30 patients with histologically proven brain tumours (25 WHO grade II-IV gliomas and five metastases) were recruited. On a 3-T system, diffusion-weighted imaging was performed with six b-values ranging from 0 to 1,700 s/mm 2 . Nonlinear least-squares fitting was employed to extract diffusion coefficient (D), diffusion kurtosis coefficient (K, a measure of the degree of non-Gaussian and heterogeneous diffusion) and intravascular volume fraction (f, a measure proportional to cerebral blood volume). Repeated-measures multivariate analysis of variance and receiver operating characteristic analysis were performed to assess the ability of D/K/f in differentiating contrast-enhanced tumour from peritumoral oedema and normal-appearing white matter. Based on our imaging setting (baseline signal-to-noise ratio = 32-128), coefficient of variation was 14-20 % for K, ~6 % for D and 26-44 % for f. The indexes were able to differentiate contrast-enhanced tumour (Wilks' λ = 0.026, p DK IVIM imaging is capable of simultaneously measuring cerebral perfusion and diffusion indexes that together may improve brain tumour diagnosis. • Hybrid DK-IVIM imaging allows simultaneous measurement of K, D and f. • Combined K/D/f better demarcates contrast-enhanced tumour than they do separately. • f correlates better with contrast-leakage-corrected CBV DSC than with uncorrected CBV DSC.

  16. Non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the Nexfin blood pressure monitor.

    Science.gov (United States)

    Stens, Jurre; Oeben, Jeroen; Van Dusseldorp, Ab A; Boer, Christa

    2016-10-01

    Nexfin beat-to-beat arterial blood pressure monitoring enables continuous assessment of hemodynamic indices like cardiac index (CI), pulse pressure variation (PPV) and stroke volume variation (SVV) in the perioperative setting. In this study we investigated whether Nexfin adequately reflects alterations in these hemodynamic parameters during a provoked fluid shift in anesthetized and mechanically ventilated patients. The study included 54 patients undergoing non-thoracic surgery with positive pressure mechanical ventilation. The provoked fluid shift comprised 15° Trendelenburg positioning, and fluid responsiveness was defined as a concomitant increase in stroke volume (SV) >10 %. Nexfin blood pressure measurements were performed during supine steady state, Trendelenburg and supine repositioning. Hemodynamic parameters included arterial blood pressure (MAP), CI, PPV and SVV. Trendelenburg positioning did not affect MAP or CI, but induced a decrease in PPV and SVV by 3.3 ± 2.8 and 3.4 ± 2.7 %, respectively. PPV and SVV returned back to baseline values after repositioning of the patient to baseline. Bland-Altman analysis of SVV and PPV showed a bias of -0.3 ± 3.0 % with limits of agreement ranging from -5.6 to 6.2 %. The SVV was more superior in predicting fluid responsiveness (AUC 0.728) than the PVV (AUC 0.636), respectively. The median bias between PPV and SVV was different for patients younger [-1.5 % (-3 to 0)] or older [+2 % (0-4.75)] than 55 years (P < 0.001), while there were no gender differences in the bias between PPV and SVV. The Nexfin monitor adequately reflects alterations in PPV and SVV during a provoked fluid shift, but the level of agreement between PPV and SVV was low. The SVV tended to be superior over PPV or Eadyn in predicting fluid responsiveness in our population.

  17. Diagnosis of hemodynamic compromise in patients with chronic cerebral ischemia; Measurement of cerebral blood volume (CBV) with sup 99m Tc-RBC SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, Satoshi; Sakuragi, Mitsugi; Motomiya, Mineo; Nakagawa, Tango; Mitsumori, Kenji; Tsuru, Mitsuo (Hokkaido Neurosurgical Memorial Hospital (Japan)); Takigawa, Shugo; Kamiyama, Hiroyasu; Abe, Hiroshi

    1990-03-01

    To evaluate the efficacy of tests for selecting patients with hemodynamic compromise, measurement of cerebral blood volume (CBV) with {sup 99m}Tc-RBC single photon emission computed tomography (SPECT) was performed in thirteen patients with occlusive cerebrovascular disease, and was compared with results obtained by {sup 133}Xe SPECT and acetazolamide (Diamox) test. All patients in our study suffered TIA, RIND, or minor completed stroke. Cerebral angiography demonstrated severe stenosis or occlusion in the ipsilateral internal carotid artery or middle cerebral artery, although plain CT scan or MRI revealed no or, if any, only localized infarcted lesions. Regional cerebral blood volume (rCBV) was measured with {sup 99m}Tc-RBC SPECT and regional cerebral blood flow (rCBF) was measured with {sup 133}Xe SPECT before and after intravenous injection of 10 - 12 mg/kg acetazolamide (Diamox). Our results suggest that the ipsilateral rCBV/rCBF (mean transit time) is a more sensitive index of the cerebral perfusion reserve than the use of only rCBV or rCBF of the ipsilateral hemisphere. Also, the ipsilateral rCBV/rCBF is significantly correlated (r= -0.72) with the Diamox reactivity of rCBF, which is considered to represent the cerebral vasodilatory capacity in patients with chronic cerebral ischemia. Postoperative SPECT study revealed remarkable improvement of ipsilateral rCBV/rCBF and Diamox reactivity in four patients who underwent EC/IC bypass surgery to improve the hemodynamic compromise. In conclusion, our results suggest that the measurement of rCBV/rCBF with {sup 133}Xe SPECT and {sup 99m}Tc-RBC SPECT is useful for detecting the hemodynamic compromise in patients with occlusive cerebrovascular disease. (author).

  18. The Effect of Low Volume Interval Training on Resting Blood Pressure in Pre-hypertensive Subjects: A Preliminary Study.

    Science.gov (United States)

    Skutnik, Benjamin C; Smith, Joshua R; Johnson, Ariel M; Kurti, Stephanie P; Harms, Craig A

    2016-01-01

    Clinically pre-hypertensive adults are at a greater risk of developing hypertension, stiffened arteries, and other cardiovascular risks. Endurance exercise training has been shown to improve elevated resting blood pressure and C-reactive protein (CRP) levels. However, a primary barrier preventing individuals from engaging in regular physical activity is a lack of time. The purpose of our study was to determine if a high-intensity interval training (HIIT) protocol would be as effective as continuous aerobic endurance training (ET) on resting blood pressure in pre-hypertensive participants. Additionally, this study investigated the effects of HIIT vs. ET on CRP. Twelve pre-hypertensive participants (33.3±6.1 yrs; 3M/9W) participated in 8 weeks of cycle ergometer exercise training. The ET exercised for 30 continuous min/day, 4 days/week at 40% VO2max reserve. The HIIT exercised at a 1:1 work-to-rest for 20 min/day, 3 days/week at 60% peak power. Resting mean arterial pressure and CRP were compared throughout the study. Both groups showed decreases (pHIIT: -8.6 ± 4.8 mmHg) following the 8 weeks. For CRP, there was a significant decrease (p=0.014) as a main effect of time. VO2max increased (pHIIT and ET. These preliminary data suggest HIIT and ET similarly decreased resting blood pressure and increased VO2max.

  19. The effect of endogenously released glucose, insulin, glucagon-like peptide 1, ghrelin on cardiac output, heart rate, stroke volume, and blood pressure

    Directory of Open Access Journals (Sweden)

    Hlebowicz Joanna

    2011-12-01

    Full Text Available Abstract Background Ingestion of a meal increases the blood flow to the gastrointestinal organs and affects the heart rate (HR, blood pressure and cardiac output (CO, although the mechanisms are not known. The aim of this study was to evaluate the effect of endogenously released glucose, insulin, glucagon-like peptide 1 (GLP-1, ghrelin on CO, HR, stroke volume (SV, and blood pressure. Methods Eleven healthy men and twelve healthy women ((mean ± SEM aged: 26 ± 0.2 y; body mass index: 21.8 ± 0.1 kg/m2 were included in this study. The CO, HR, SV, systolic and diastolic blood pressure, antral area, gastric emptying rate, and glucose, insulin, GLP-1 and ghrelin levels were measured. Results The CO and SV at 30 min were significantly higher, and the diastolic blood pressure was significantly lower, than the fasting in both men and women (P P = 0.015, r = 0.946, and between ghrelin levels and HR (P = 0.013, r = 0.951 at 110 min. Significant correlations were also found between the change in glucose level at 30 min and the change in systolic blood pressure (P = 0.021, r = -0.681, and the change in SV (P = 0.008, r = -0.748 relative to the fasting in men. The insulin 0-30 min AUC was significantly correlated to the CO 0-30 min AUC (P = 0.002, r = 0.814 in men. Significant correlations were also found between the 0-120 min ghrelin and HR AUCs (P = 0.007, r = 0.966 in men. No statistically significant correlations were seen in women. Conclusions Physiological changes in the levels of glucose, insulin, GLP-1 and ghrelin may influence the activity of the heart and the blood pressure. There may also be gender-related differences in the haemodynamic responses to postprandial changes in hormone levels. The results of this study show that subjects should not eat immediately prior to, or during, the evaluation of cardiovascular interventions as postprandial affects may affect the results, leading to erroneous interpretation of the cardiovascular effects of the

  20. [The assessment of ultrasonic measurement of superior vena cava blood flow for the volume responsiveness of patients with mechanical ventilation].

    Science.gov (United States)

    Guo, Zhe; He, Wei; Hou, Jing; Li, Tong; Zhou, Hua; Xu, Yuan; Xi, Xiuming

    2014-09-01

    To approach the evaluative effect of respiratory variation of superior vena cava peak flow velocity measured using transthoracic echocardiography (TTE) on fluid responsiveness in patients with mechanical ventilation. A prospective cohort study was conducted. All mechanical ventilated critically ill patients whose fluid therapy was planned due to hypovolemia in Department of Critical Care Medicine of Beijing Tongren Hospital of Capital Medical University from April 2011 to April 2013 were enrolled. Volume expansion was performed with 500 mL Linger solution within 30 minutes. Patients were classified as responders if pulse pressure variation (PPV) increased ≥ 13% before volume expansion. The respiratory variation in superior vena cava peak velocity was calculated as the difference between maximum and minimum values of velocity in peak A, peak S and peak D over a single respiratory circle, and their variations (ΔA, ΔS, ΔD) were also calculated. The receiver operating characteristic curve (ROC curve) was plotted to assess the evaluative effect of respiratory variation of superior vena cava peak velocity on fluid responsiveness. Twenty-seven patients were enrolled in this study. Volume expansion increased PPV ≥ 13% happened in 14 patients (responders). The velocity of superior vena cava in peak A, peak S, peak D was significantly increased after volume expansion compared with that before volume expansion in responders [peak A (cm/s): 34.6 ± 2.2 vs. 31.3 ± 2.1, t=-2.493, P=0.027; peak S (cm/s): 39.1 ± 1.3 vs. 35.3 ± 2.1, t=-2.564, P=0.024; peak D (cm/s): 28.1 ± 1.2 vs. 23.3 ± 1.4, t=-4.995, P=0.000], but there was no significant difference in ΔA, ΔS and ΔD between before and after volume expansion. The ΔA, ΔS and ΔD were positively correlated with PPV (r=0.040, P=0.854; r=0.350, P=0.074; r=0.749, P=0.000). The area under ROC curve (AUC) of peak S was 0.36 [95% confidence interval (95%CI): 0.11-0.52], but the AUC of ΔS was 0.68 (95%CI 0.47-0.89), the

  1. Intra-lesional spatial correlation of static and dynamic FET-PET parameters with MRI-based cerebral blood volume in patients with untreated glioma

    Energy Technology Data Exchange (ETDEWEB)

    Goettler, Jens; Preibisch, Christine [TU Muenchen, Department of Neuroradiology, Klinikum rechts der Isar, Munich (Germany); TU Muenchen, TUM Neuroimaging Center (TUM-NIC), Klinikum rechts der Isar, Munich (Germany); Lukas, Mathias; Mustafa, Mona; Schwaiger, Markus; Pyka, Thomas [TU Muenchen, Department of Nuclear Medicine, Klinikum rechts der Isar, Munich (Germany); Kluge, Anne; Kaczmarz, Stephan; Zimmer, Claus [TU Muenchen, Department of Neuroradiology, Klinikum rechts der Isar, Munich (Germany); Gempt, Jens; Ringel, Florian; Meyer, Bernhard [TU Muenchen, Department of Neurosurgery, Klinikum rechts der Isar, Munich (Germany); Foerster, Stefan [TU Muenchen, TUM Neuroimaging Center (TUM-NIC), Klinikum rechts der Isar, Munich (Germany); TU Muenchen, Department of Nuclear Medicine, Klinikum rechts der Isar, Munich (Germany); Klinikum Bayreuth, Department of Nuclear Medicine, Bayreuth (Germany)

    2017-03-15

    {sup 18}F-fluorethyltyrosine-(FET)-PET and MRI-based relative cerebral blood volume (rCBV) have both been used to characterize gliomas. Recently, inter-individual correlations between peak static FET-uptake and rCBV have been reported. Herein, we assess the local intra-lesional relation between FET-PET parameters and rCBV. Thirty untreated glioma patients (27 high-grade) underwent simultaneous PET/MRI on a 3 T hybrid scanner obtaining structural and dynamic susceptibility contrast sequences. Static FET-uptake and dynamic FET-slope were correlated with rCBV within tumour hotspots across patients and intra-lesionally using a mixed-effects model to account for inter-individual variation. Furthermore, maximal congruency of tumour volumes defined by FET-uptake and rCBV was determined. While the inter-individual relationship between peak static FET-uptake and rCBV could be confirmed, our intra-lesional, voxel-wise analysis revealed significant positive correlations (median r = 0.374, p < 0.0001). Similarly, significant inter- and intra-individual correlations were observed between FET-slope and rCBV. However, rCBV explained only 12% of the static and 5% of the dynamic FET-PET variance and maximal overlap of respective tumour volumes was 37% on average. Our results show that the relation between peak values of MR-based rCBV and static FET-uptake can also be observed intra-individually on a voxel basis and also applies to a dynamic FET parameter, possibly determining hotspots of higher biological malignancy. However, just a small part of the FET-PET signal variance is explained by rCBV and tumour volumes determined by the two modalities showed only moderate overlap. These findings indicate that FET-PET and MR-based rCBV provide both congruent and complimentary information on glioma biology. (orig.)

  2. Intra-lesional spatial correlation of static and dynamic FET-PET parameters with MRI-based cerebral blood volume in patients with untreated glioma.

    Science.gov (United States)

    Göttler, Jens; Lukas, Mathias; Kluge, Anne; Kaczmarz, Stephan; Gempt, Jens; Ringel, Florian; Mustafa, Mona; Meyer, Bernhard; Zimmer, Claus; Schwaiger, Markus; Förster, Stefan; Preibisch, Christine; Pyka, Thomas

    2017-03-01

    18 F-fluorethyltyrosine-(FET)-PET and MRI-based relative cerebral blood volume (rCBV) have both been used to characterize gliomas. Recently, inter-individual correlations between peak static FET-uptake and rCBV have been reported. Herein, we assess the local intra-lesional relation between FET-PET parameters and rCBV. Thirty untreated glioma patients (27 high-grade) underwent simultaneous PET/MRI on a 3 T hybrid scanner obtaining structural and dynamic susceptibility contrast sequences. Static FET-uptake and dynamic FET-slope were correlated with rCBV within tumour hotspots across patients and intra-lesionally using a mixed-effects model to account for inter-individual variation. Furthermore, maximal congruency of tumour volumes defined by FET-uptake and rCBV was determined. While the inter-individual relationship between peak static FET-uptake and rCBV could be confirmed, our intra-lesional, voxel-wise analysis revealed significant positive correlations (median r = 0.374, p dynamic FET-PET variance and maximal overlap of respective tumour volumes was 37% on average. Our results show that the relation between peak values of MR-based rCBV and static FET-uptake can also be observed intra-individually on a voxel basis and also applies to a dynamic FET parameter, possibly determining hotspots of higher biological malignancy. However, just a small part of the FET-PET signal variance is explained by rCBV and tumour volumes determined by the two modalities showed only moderate overlap. These findings indicate that FET-PET and MR-based rCBV provide both congruent and complimentary information on glioma biology.

  3. CORRELATION OF VOLUME BLOOD CIRCULATION IN THE HEPATIC ARTERY AND THE STATE OF MICROCIRCULATORY BLOODSTREAM OF THE TRANSPLANTED LIVER AFTER ITS REVASCULIZATION

    Directory of Open Access Journals (Sweden)

    D. A. Granov

    2014-01-01

    Full Text Available Aim: optimization of the surgical treatment policy with orthotopic liver transplantation (OLT depending on the results of intraoperative fl owmetry and the state of intrahepatic microcirculatory bloodstream according to immunohistochemical (IHC study of microspecimens of the donor’s liver.Materials and methods. 60 patients are included in the study. Group I (n = 30 comprised of patients for whom it was not necessary to perform any additional interventions on the bloodstream in the hepatopancreatobiliary area during OLT. Group II (n = 30 had patients with insuffi cient arterial blood supply for the graft in the intraoperative stage where it was needed to perform additional and/or repeated interventions in the arteries of the hepatopancreatobilliary area. Intraoperative fl owmetry with assessment of the volume blood circulation (VBC in the hepatic artery (HA was carried out in the both studied groups. Reference value of VBC was 100 ml/min and higher. Before and after reperfusion in the liver biopsy material we performed immunohistochemical study with the use of endothelial marker CD 31 with subsequent morphometric estimation of the specifi c square of the microvascular bloodstream.Results. In both groups there was no change in the specifi c square in the areas of portal tract and central vein before and after restoring blood fl ow. In the second group, an 8 times increase of the specifi c square of sinusoids was observed after restoring blood fl ow (р < 0,01.Conclusion. Intraoperative fl owmetric control of the blood fl ow allows in due time to perform surgical correction of the graft arterial blood supply during OLT, and it reduces the risk of thrombosis up to 0%. The value of VBC in the hepatic artery (HA has reliable dependence upon the state of microcirculatory bloodstream of cadaveric donor’s liver after reperfusion.

  4. Quantitation of regional cerebral blood flow corrected for partial volume effect using O-15 water and PET: II. Normal values and gray matter blood flow response to visual activation

    DEFF Research Database (Denmark)

    Law, I; Iida, H; Holm, S

    2000-01-01

    One of the most limiting factors for the accurate quantification of physiologic parameters with positron emission tomography (PET) is the partial volume effect (PVE). To assess the magnitude of this contribution to the measurement of regional cerebral blood flow (rCBF), the authors have formulated...... or 3D). Furthermore, the authors wanted to measure the activation response in the occipital gray matter compartment, and in doing so test the stability of the PTF, during perturbations of rCBF induced by visual stimulation. Eight dynamic PET scans were acquired per subject (n = 8), each for a duration...... of 6 minutes after IV bolus injection of H2(15)O. Four of these scans were performed using 2D and four using 3D acquisition. Visual stimulation was presented in four scans, and four scans were during rest. Model C was found optimal based on Akaike's Information Criteria (AIC) and had the smallest...

  5. Interleaved quantitative BOLD: Combining extravascular R2' - and intravascular R2-measurements for estimation of deoxygenated blood volume and hemoglobin oxygen saturation.

    Science.gov (United States)

    Lee, Hyunyeol; Englund, Erin K; Wehrli, Felix W

    2018-03-23

    Quantitative BOLD (qBOLD), a non-invasive MRI method for assessment of hemodynamic and metabolic properties of the brain in the baseline state, provides spatial maps of deoxygenated blood volume fraction (DBV) and hemoglobin oxygen saturation (HbO 2 ) by means of an analytical model for the temporal evolution of free-induction-decay signals in the extravascular compartment. However, mutual coupling between DBV and HbO 2 in the signal model results in considerable estimation uncertainty precluding achievement of a unique set of solutions. To address this problem, we developed an interleaved qBOLD method (iqBOLD) that combines extravascular R 2 ' and intravascular R 2 mapping techniques so as to obtain prior knowledge for the two unknown parameters. To achieve these goals, asymmetric spin echo and velocity-selective spin-labeling (VSSL) modules were interleaved in a single pulse sequence. Prior to VSSL, arterial blood and CSF signals were suppressed to produce reliable estimates for cerebral venous blood volume fraction (CBV v ) as well as venous blood R 2 (to yield HbO 2 ). Parameter maps derived from the VSSL module were employed to initialize DBV and HbO 2 in the qBOLD processing. Numerical simulations and in vivo experiments at 3 T were performed to evaluate the performance of iqBOLD in comparison to the parent qBOLD method. Data obtained in eight healthy subjects yielded plausible values averaging 60.1 ± 3.3% for HbO 2 and 3.1 ± 0.5 and 2.0 ± 0.4% for DBV in gray and white matter, respectively. Furthermore, the results show that prior estimates of CBV v and HbO 2 from the VSSL component enhance the solution stability in the qBOLD processing, and thus suggest the feasibility of iqBOLD as a promising alternative to the conventional technique for quantifying neurometabolic parameters. Copyright © 2018. Published by Elsevier Inc.

  6. Veje ind og ud af hjemløshed

    DEFF Research Database (Denmark)

    Benjaminsen, Lars; Enemark, Morten Holm

    Hjemløsheden i Danmark har været stigende i de seneste år. Denne rapport beskriver forløbene op mod hjemløshed, vejene gennem hjemløshed og chancerne for at komme ud af hjemløshed igen. På baggrund af data fra hjemløsetællingerne og fra landets herberger (§ 110-boformer) i perioden 2009-2015 anal...

  7. Load shedding scheme in the south/southeastern interconnected system

    Energy Technology Data Exchange (ETDEWEB)

    Vieira Filho, Xisto; Couri, J J.G.; Gomes, P; Almeida, P C [ELETROBRAS, Rio de Janeiro, RJ (Brazil)

    1988-12-31

    This paper presents some characteristics of the Brazilian interconnected system and discusses the load shedding scheme in its different stages considering the beginning of operation of the Itaipu power plant. The present situation of the South and Southeastern load shedding scheme combination is also commented. Finally, the interconnected system evolution and the effects on the load shedding schemes are discussed. 4 refs., 5 figs., 2 tabs.

  8. Effects of delayed cord clamping on residual placental blood volume, hemoglobin and bilirubin levels in term infants: a randomized controlled trial.

    Science.gov (United States)

    Mercer, J S; Erickson-Owens, D A; Collins, J; Barcelos, M O; Parker, A B; Padbury, J F

    2017-03-01

    The objective of the study was to measure the effects of a 5-min delay (DCC) versus immediate cord clamping (ICC) on residual placental blood volume (RPBV) at birth, and hemoglobin and serum bilirubin at 24 to 48 h of age. In this prospective randomized controlled trial, 73 women with term (37 to 41 weeks) singleton fetuses were randomized to DCC (⩾5 min; n=37) or ICC (protocol violations. Cord milking was the proxy for DCC (n=11) when the provider could not wait. Infants randomized to DCC compared with ICC had significantly less RPBV (20.0 versus 30.8 ml kg -1 , Phemoglobin levels (19.4 versus 17.8 g dl -1 , P=0.002) at 24 to 48 h, with no difference in bilirubin levels. Term infants had early hematological advantage of DCC without increases in hyperbilirubinemia or symptomatic polycythemia.

  9. Quantitation of regional cerebral blood flow corrected for partial volume effect using O-15 water and PET: I. Theory, error analysis, and stereologic comparison

    DEFF Research Database (Denmark)

    Lida, H; Law, I; Pakkenberg, B

    2000-01-01

    Limited spatial resolution of positron emission tomography (PET) can cause significant underestimation in the observed regional radioactivity concentration (so-called partial volume effect or PVE) resulting in systematic errors in estimating quantitative physiologic parameters. The authors have...... formulated four mathematical models that describe the dynamic behavior of a freely diffusible tracer (H215O) in a region of interest (ROI) incorporating estimates of regional tissue flow that are independent of PVE. The current study was intended to evaluate the feasibility of these models and to establish...... a methodology to accurately quantify regional cerebral blood flow (CBF) corrected for PVE in cortical gray matter regions. Five monkeys were studied with PET after IV H2(15)O two times (n = 3) or three times (n = 2) in a row. Two ROIs were drawn on structural magnetic resonance imaging (MRI) scans and projected...

  10. Shedding Light on Dark Liquidity Pools

    NARCIS (Netherlands)

    Degryse, H.A.; van Achter, M.; Wuyts, G.

    2008-01-01

    This article reviews the recent developments on dark liquidity pools starting from the theoretical and empirical academic literature. The number of dark liquidity pools as well as their trading volume has grown substantially in the last couple of years. We highlight the incentives of providers as

  11. Small volume transfusion of irradiated red blood cells using satellite bags in very low birth weight infants

    International Nuclear Information System (INIS)

    Yamagiwa, Kazuhiro; Honda, Yoshinobu; Sakuma, Kimiko; Igarashi, Etsuo; Watanabe, Masahiko; Ujiie, Niro; Suzuki, Hitoshi; Ohto, Hitoshi

    1993-01-01

    We have treated anemia of prematurity with concentrated red cells divided into 3 packs by using the Sterile Connection Device (SCD, USA). This study was performed to reveal the influence for very low birth weight infants of transfusion of red cells stored after irradiation. The following facts were observed in infants after transfusion: (1) no change in sodium and potassium level and leucocyte count, (2) increased amount of total bilirubin but no change in unbound bilirubin level, (3) decrease in platelet count less than 50,000/mm 3 . According to these results we conclude that the transfusion of concentrated red blood cells stored within 2 weeks after irradiation was safe even for very low birth weight infants. (author)

  12. Cryogenic transmission electron microscopy nanostructural study of shed microparticles.

    Directory of Open Access Journals (Sweden)

    Liron Issman

    Full Text Available Microparticles (MPs are sub-micron membrane vesicles (100-1000 nm shed from normal and pathologic cells due to stimulation or apoptosis. MPs can be found in the peripheral blood circulation of healthy individuals, whereas elevated concentrations are found in pregnancy and in a variety of diseases. Also, MPs participate in physiological processes, e.g., coagulation, inflammation, and angiogenesis. Since their clinical properties are important, we have developed a new methodology based on nano-imaging that provides significant new data on MPs nanostructure, their composition and function. We are among the first to characterize by direct-imaging cryogenic transmitting electron microscopy (cryo-TEM the near-to-native nanostructure of MP systems isolated from different cell types and stimulation procedures. We found that there are no major differences between the MP systems we have studied, as most particles were spherical, with diameters from 200 to 400 nm. However, each MP population is very heterogeneous, showing diverse morphologies. We investigated by cryo-TEM the effects of standard techniques used to isolate and store MPs, and found that either high-g centrifugation of MPs for isolation purposes, or slow freezing to -80 °C for storage introduce morphological artifacts, which can influence MP nanostructure, and thus affect the efficiency of these particles as future diagnostic tools.

  13. Ebola Virus Shedding and Transmission: Review of Current Evidence.

    Science.gov (United States)

    Vetter, Pauline; Fischer, William A; Schibler, Manuel; Jacobs, Michael; Bausch, Daniel G; Kaiser, Laurent

    2016-10-15

     The magnitude of the 2013-2016 Ebola virus disease outbreak in West Africa was unprecedented, with >28 500 reported cases and >11 000 deaths. Understanding the key elements of Ebola virus transmission is necessary to implement adequate infection prevention and control measures to protect healthcare workers and halt transmission in the community.  We performed an extensive PubMed literature review encompassing the period from discovery of Ebola virus, in 1976, until 1 June 2016 to evaluate the evidence on modes of Ebola virus shedding and transmission.  Ebola virus has been isolated by cell culture from blood, saliva, urine, aqueous humor, semen, and breast milk from infected or convalescent patients. Ebola virus RNA has been noted in the following body fluids days or months after onset of illness: saliva (22 days), conjunctiva/tears (28 days), stool (29 days), vaginal fluid (33 days), sweat (44 days), urine (64 days), amniotic fluid (38 days), aqueous humor (101 days), cerebrospinal fluid (9 months), breast milk (16 months [preliminary data]), and semen (18 months). Nevertheless, the only documented cases of secondary transmission from recovered patients have been through sexual transmission. We did not find strong evidence supporting respiratory or fomite-associated transmission. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  14. Simultaneous evaluation of brain tumour metabolism, structure and blood volume using [{sup 18}F]-fluoroethyltyrosine (FET) PET/MRI: feasibility, agreement and initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Henriksen, Otto M.; Hansen, Adam E.; Law, Ian [Copenhagen University Hospital Rigshospitalet Blegdamsvej, Department of Clinical Physiology Nuclear Medicine and PET, Copenhagen (Denmark); Larsen, Vibeke A. [Copenhagen University Hospital Rigshospitalet Blegdamsvej, Department of Radiology, Copenhagen (Denmark); Muhic, Aida; Poulsen, Hans S. [Copenhagen University Hospital Rigshospitalet Blegdamsvej, Department of Oncology, Copenhagen (Denmark); Larsson, Henrik B.W. [Copenhagen University Hospital Rigshospitalet Glostrup, Functional Imaging Unit, Department of Clinical Physiology Nuclear Medicine and PET, Glostrup (Denmark)

    2016-01-15

    Both [{sup 18}F]-fluoroethyltyrosine (FET) PET and blood volume (BV) MRI supplement routine T1-weighted contrast-enhanced MRI in gliomas, but whether the two modalities provide identical or complementary information is unresolved. The aims of the study were to investigate the feasibility of simultaneous structural MRI, BV MRI and FET PET of gliomas using an integrated PET/MRI scanner and to assess the spatial and quantitative agreement in tumour imaging between BV MRI and FET PET. A total of 32 glioma patients underwent a 20-min static simultaneous PET/MRI acquisition on a Siemens mMR system 20 min after injection of 200 MBq FET. The MRI protocol included standard structural MRI and dynamic susceptibility contrast (DSC) imaging for BV measurements. Maximal relative tumour FET uptake (TBR{sub max}) and BV (rBV{sub max}), and Dice coefficients were calculated to assess the quantitative and spatial congruence in the tumour volumes determined by FET PET, BV MRI and contrast-enhanced MRI. FET volume and TBR{sub max} were higher in BV-positive than in BV-negative scans, and both VOL{sub BV} and rBV{sub max} were higher in FET-positive than in FET-negative scans. TBR{sub max} and rBV{sub max} were positively correlated (R{sup 2} = 0.59, p < 0.001). FET and BV positivity were in agreement in only 26 of the 32 patients and in 42 of 63 lesions, and spatial congruence in the tumour volumes as assessed by the Dice coefficients was generally poor with median Dice coefficients exceeding 0.1 in less than half the patients positive on at least one modality for any pair of modalities. In 56 % of the patients susceptibility artefacts in DSC BV maps overlapped the tumour on MRI. The study demonstrated that although tumour volumes determined by BV MRI and FET PET were quantitatively correlated, their spatial congruence in a mixed population of treated glioma patients was generally poor, and the modalities did not provide the same information in this population of patients. Combined

  15. MR vascular fingerprinting: A new approach to compute cerebral blood volume, mean vessel radius, and oxygenation maps in the human brain.

    Science.gov (United States)

    Christen, T; Pannetier, N A; Ni, W W; Qiu, D; Moseley, M E; Schuff, N; Zaharchuk, G

    2014-04-01

    In the present study, we describe a fingerprinting approach to analyze the time evolution of the MR signal and retrieve quantitative information about the microvascular network. We used a Gradient Echo Sampling of the Free Induction Decay and Spin Echo (GESFIDE) sequence and defined a fingerprint as the ratio of signals acquired pre- and post-injection of an iron-based contrast agent. We then simulated the same experiment with an advanced numerical tool that takes a virtual voxel containing blood vessels as input, then computes microscopic magnetic fields and water diffusion effects, and eventually derives the expected MR signal evolution. The parameter inputs of the simulations (cerebral blood volume [CBV], mean vessel radius [R], and blood oxygen saturation [SO2]) were varied to obtain a dictionary of all possible signal evolutions. The best fit between the observed fingerprint and the dictionary was then determined by using least square minimization. This approach was evaluated in 5 normal subjects and the results were compared to those obtained by using more conventional MR methods, steady-state contrast imaging for CBV and R and a global measure of oxygenation obtained from the superior sagittal sinus for SO2. The fingerprinting method enabled the creation of high-resolution parametric maps of the microvascular network showing expected contrast and fine details. Numerical values in gray matter (CBV=3.1±0.7%, R=12.6±2.4μm, SO2=59.5±4.7%) are consistent with literature reports and correlated with conventional MR approaches. SO2 values in white matter (53.0±4.0%) were slightly lower than expected. Numerous improvements can easily be made and the method should be useful to study brain pathologies. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. EVIDENCE OF PSEUDORABIES VIRUS SHEDDING IN FERAL SWINE ( SUS SCROFA) POPULATIONS OF FLORIDA, USA.

    Science.gov (United States)

    Hernández, Felipe A; Sayler, Katherine A; Bounds, Courtney; Milleson, Michael P; Carr, Amanda N; Wisely, Samantha M

    2018-01-01

    :  Feral swine ( Sus scrofa) are a pathogen reservoir for pseudorabies virus (PrV). The virus can be fatal to wildlife and contributes to economic losses in the swine industry worldwide. National surveillance efforts in the US use serology to detect PrV-specific antibodies in feral swine populations, but PrV exposure is not a direct indicator of pathogen transmission among conspecifics or to non-suid wildlife species. We measured antibody production and the presence of PrV DNA in four tissue types from feral swine populations of Florida, US. We sampled blood, nasal, oral, and genital swabs from 551 individuals at 39 sites during 2014-16. Of the animals tested for antibody production, 224 of 436 (51%) feral swine were antibody positive while 38 of 549 feral swine (7%) tested for viral shedding were quantitative polymerase chain reaction (qPCR)-positive for PrV. The detection of PrV DNA across all the collected sample types (blood, nasal, oral, and genital [vaginal] swabs) suggested viral shedding via direct (oronasal or venereal), and potentially indirect (through carcass consumption), routes of transmission among infected and susceptible animals. Fourteen of 212 seronegative feral swine were qPCR-positive, indicating 7% false negatives in the serologic assay. Our findings suggest that serology may underestimate the actual infection risk posed by feral swine to other species and that feral swine populations in Florida are capable of shedding the virus through multiple routes.

  17. Diagnostic examination performance by using microvascular leakage, cerebral blood volume, and blood flow derived from 3-T dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging in the differentiation of glioblastoma multiforme and brain metastasis

    International Nuclear Information System (INIS)

    Server, Andres; Nakstad, Per H.; Orheim, Tone E.D.; Graff, Bjoern A.; Josefsen, Roger; Kumar, Theresa

    2011-01-01

    Conventional magnetic resonance (MR) imaging has limited capacity to differentiate between glioblastoma multiforme (GBM) and metastasis. The purposes of this study were: (1) to compare microvascular leakage (MVL), cerebral blood volume (CBV), and blood flow (CBF) in the distinction of metastasis from GBM using dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging (DSC-MRI), and (2) to estimate the diagnostic accuracy of perfusion and permeability MR imaging. A prospective study of 61 patients (40 GBMs and 21 metastases) was performed at 3 T using DSC-MRI. Normalized rCBV and rCBF from tumoral (rCBVt, rCBFt), peri-enhancing region (rCBVe, rCBFe), and by dividing the value in the tumor by the value in the peri-enhancing region (rCBVt/e, rCBFt/e), as well as MVL were calculated. Hemodynamic and histopathologic variables were analyzed statistically and Spearman/Pearson correlations. Receiver operating characteristic curve analysis was performed for each of the variables. The rCBVe, rCBFe, and MVL were significantly greater in GBMs compared with those of metastases. The optimal cutoff value for differentiating GBM from metastasis was 0.80 which implies a sensitivity of 95%, a specificity of 92%, a positive predictive value of 86%, and a negative predictive value of 97% for rCBVe ratio. We found a modest correlation between rCBVt and rCBFt ratios. MVL measurements in GBMs are significantly higher than those in metastases. Statistically, both rCBVe, rCBVt/e and rCBFe, rCBFt/e were useful in differentiating between GBMs and metastases, supporting the hypothesis that perfusion MR imaging can detect infiltration of tumor cells in the peri-enhancing region. (orig.)

  18. Diagnostic examination performance by using microvascular leakage, cerebral blood volume, and blood flow derived from 3-T dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging in the differentiation of glioblastoma multiforme and brain metastasis

    Energy Technology Data Exchange (ETDEWEB)

    Server, Andres; Nakstad, Per H. [Oslo University Hospital-Ullevaal, Section of Neuroradiology, Department of Radiology and Nuclear Medicine, Oslo (Norway); University of Oslo, Oslo (Norway); Orheim, Tone E.D. [Oslo University Hospital, Interventional Centre, Oslo (Norway); Graff, Bjoern A. [Oslo University Hospital-Ullevaal, Department of Radiology and Nuclear Medicine, Oslo (Norway); Josefsen, Roger [Oslo University Hospital-Ullevaal, Department of Neurosurgery, Oslo (Norway); Kumar, Theresa [Oslo University Hospital-Ullevaal, Department of Pathology, Oslo (Norway)

    2011-05-15

    Conventional magnetic resonance (MR) imaging has limited capacity to differentiate between glioblastoma multiforme (GBM) and metastasis. The purposes of this study were: (1) to compare microvascular leakage (MVL), cerebral blood volume (CBV), and blood flow (CBF) in the distinction of metastasis from GBM using dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging (DSC-MRI), and (2) to estimate the diagnostic accuracy of perfusion and permeability MR imaging. A prospective study of 61 patients (40 GBMs and 21 metastases) was performed at 3 T using DSC-MRI. Normalized rCBV and rCBF from tumoral (rCBVt, rCBFt), peri-enhancing region (rCBVe, rCBFe), and by dividing the value in the tumor by the value in the peri-enhancing region (rCBVt/e, rCBFt/e), as well as MVL were calculated. Hemodynamic and histopathologic variables were analyzed statistically and Spearman/Pearson correlations. Receiver operating characteristic curve analysis was performed for each of the variables. The rCBVe, rCBFe, and MVL were significantly greater in GBMs compared with those of metastases. The optimal cutoff value for differentiating GBM from metastasis was 0.80 which implies a sensitivity of 95%, a specificity of 92%, a positive predictive value of 86%, and a negative predictive value of 97% for rCBVe ratio. We found a modest correlation between rCBVt and rCBFt ratios. MVL measurements in GBMs are significantly higher than those in metastases. Statistically, both rCBVe, rCBVt/e and rCBFe, rCBFt/e were useful in differentiating between GBMs and metastases, supporting the hypothesis that perfusion MR imaging can detect infiltration of tumor cells in the peri-enhancing region. (orig.)

  19. The effect of acetazolamide on cerebral blood volume and intracranial pressure in patients with hydrocephalus. Theoretical background of the acetazolamide challenge test

    International Nuclear Information System (INIS)

    Ogawa, Daiji

    2000-01-01

    The acetazolamide challenge test is one of the useful tests for diagnosing normal pressure hydrocephalus (NPH). It has the advantage of being less invasive than other tests. However, the manner of increment in cerebral blood volume (CBV) has not been well clarified. Therefore, the theoretical background of the test is also unclear. The aims of this study were to evaluate the effect of acetazolamide on CBV and intracranial pressure (ICP) and elucidate the theoretical background of the test. Thirteen patients with NPH were studied. CBV and ICP were measured before and after the intravenous injection of acetazolamide (1000 mg). CBV was evaluated by means of cerebral pool SPECT; ICP was evaluated by OSAKA telesensor or a pressure transducer via ventricular catheter. Immediately after the injection, CBV increased rapidly, reaching its maximum (15% increase) at 6 minutes. Then CBV gradually decreased. ICP also elevated rapidly, reaching its maximum (12.6 mmHg elevation) at 4 minutes. A gradual decrement ICP was observed, and 26 minutes after injection, the ICP became lower than the pre-injection level. The rapid increase in CBV caused the ICP elevation, and the increment ratio reflected the cerebral compliance. Therefore, we concluded that the acetazolamide challenge test is based on the alteration of cerebral compliance seen in NPH patients. The decrement ratio of ICP is affected not only by the resistance cerebrospinal fluid (CSF) absorption but also by decrease in the CBV and CSF production induced by acetazolamide. Consequently, it is difficult to evaluate the resistance of CSF absorption by this test. Because CBV increased in all cases, it is assumed that acetazolamide administration can be used to reliably load the volume. (author)

  20. The relationship between pulmonary artery wedge pressure and pulmonary blood volume derived from contrast echocardiography: A proof-of-concept study.

    Science.gov (United States)

    Monahan, Ken; Lenihan, Daniel; Brittain, Evan L; Saliba, Linda; Piana, Robert N; Robison, Leslie L; Hudson, Melissa M; Armstrong, Gregory T

    2018-05-14

    Pulmonary transit time (PTT) obtained from contrast echocardiography is a marker of global cardiopulmonary function. Pulmonary blood volume (PBV), derived from PTT, may be a noninvasive surrogate for left-sided filling pressures, such as pulmonary artery wedge pressure (PAWP). We sought to assess the relationship between PBV obtained from contrast echocardiography and PAWP. Participants were adult survivors of childhood cancer that had contrast echocardiography performed nearly simultaneously with right-heart catheterization. PTT was derived from time-intensity curves of contrast passage through the right ventricle (RV) and left atrium (LA). PBV relative to overall stroke volume (rPBV) was estimated from the product of PTT and heart rate during RV-LA transit. PAWP was obtained during standard right-heart catheterization. The Spearman correlation coefficient was used to assess the relationship between rPBV and PAWP. The study population consisted of 7 individuals who had contrast echocardiography and right-heart catheterization within 3 hours of each other. There was a wide range of right atrial (1-17 mm Hg), mean pulmonary artery (18-42 mm Hg), and PAW pressures (4-26 mm Hg) as well as pulmonary vascular resistance (<1-6 Wood Units). We observed a statistically significant correlation between rPBV and PAWP (r = .85; P = .02). Relative PBV derived from contrast echocardiography correlates with PAWP. If validated in larger studies, rPBV could potentially be used as an alternative to invasively determine left-sided filling pressure. © 2018 Wiley Periodicals, Inc.

  1. Effect of pyloroplasty and fundectomy on the delay of gastric emptying and gastrointestinal transit of liquid elicited by acute blood volume expansion in awake rats

    Directory of Open Access Journals (Sweden)

    M.C.V. Rêgo

    1998-03-01

    Full Text Available We evaluated the effects of fundectomy and pyloroplasty on the delay of gastric emptying (GE and gastrointestinal (GI transit of liquid due to blood volume (BV expansion in awake rats. Male Wistar rats (N = 76, 180-250 g were first submitted to fundectomy (N = 26, Heinecke-Mikulicz pyloroplasty (N = 25 or SHAM laparotomy (N = 25. After 6 days, the left external jugular vein was cannulated and the animals were fasted for 24 h with water ad libitum. The test meal was administered intragastrically (1.5 ml of a phenol red solution, 0.5 mg/ml in 5% glucose to normovolemic control animals and to animals submitted to BV expansion (Ringer-bicarbonate, iv infusion, 1 ml/min, volume up to 5% body weight. BV expansion decreased GE and GI transit rates in SHAM laparotomized animals by 52 and 35.9% (P<0.05. Fundectomy increased GE and GI transit rates by 61.1 and 67.7% (P<0.05 and prevented the effect of expansion on GE but not on GI transit (13.9% reduction, P<0.05. Pyloroplasty also increased GE and GI transit rates by 33.9 and 44.8% (P<0.05 but did not prevent the effect of expansion on GE or GI transit (50.7 and 21.1% reduction, P<0.05. Subdiaphragmatic vagotomy blocked the effect of expansion on GE and GI transit in both SHAM laparotomized animals and animals submitted to pyloroplasty. In conclusion 1 the proximal stomach is involved in the GE delay due to BV expansion but is not essential for the establishment of a delay in GI transit, which suggests the activation of intestinal resistances, 2 pyloric modulation was not apparent, and 3 vagal pathways are involved

  2. Relationship between ischemic ST depression pattern and coronary blood volume. Study using 13NH3 positron emission computed tomography under light exercise

    International Nuclear Information System (INIS)

    Watabe, Takuya; Okazaki, Osamu; Michihata, Tetsuo; Hara, Toshihiko; Harumi, Kenichi; Akutsu, Yasushi; Yamanaka, Hideyuki; Katagiri, Takashi.

    1994-01-01

    To determine the relationship between ST depression pattern and coronary blood volume in exercise induced myocardial ischemia, exercise-induced ST changes on ECG and regional myocardial blood flow (RMBF) on positron emission computed tomography (PET) were examined. The subjects were 41 patients with myocardial infarction and 30 with angina pectoris, consisting of 55 men and 16 women. Five normal men served as controls. In the group of ST depression, maximum PRP and age were significantly high, and patients with multiple vessel disease accounted for 63.6%. RMBF, as shown on PET, increased by 10% or more after exercise in 71.1% in the group of non ST change and in the control group. In 60.6% of the patients having ST depression, there was a decrease in RMBF or an unfavorable increase in RMBF. Among 33 patients in the group of ST depression, 17 had a sagging type. Of these 17, 12 (70.6%) showed a decrease of RMBF or an unfavorable increase in RMBF, and 10 had triple vessel disease. Sixteen patients had a horizontal type, 8 of whom (50.0%) had a decrease or unfavorable increase in RMBF. These findings suggest that a decrease or unfavorable increase (an increased rate of 10% or less) may be involved in the occurrence of ST depression induced by exercise. In particular, patients with a sagging type ST depression should be monitored during exercise because many of these patients may have triple vessel disease and a decrease or unfavorable increase in RMBF. (N.K.)

  3. Numerical Simulations of Vortex Shedding in Hydraulic Turbines

    Science.gov (United States)

    Dorney, Daniel; Marcu, Bogdan

    2004-01-01

    Turbomachines for rocket propulsion applications operate with many different working fluids and flow conditions. Oxidizer boost turbines often operate in liquid oxygen, resulting in an incompressible flow field. Vortex shedding from airfoils in this flow environment can have adverse effects on both turbine performance and durability. In this study the effects of vortex shedding in a low-pressure oxidizer turbine are investigated. Benchmark results are also presented for vortex shedding behind a circular cylinder. The predicted results are compared with available experimental data.

  4. Less impairment of hemostasis and reduced blood loss in pigs after resuscitation from hemorrhagic shock using the small-volume concept with hypertonic saline/hydroxyethyl starch as compared to administration of 4% gelatin or 6% hydroxyethyl starch solution.

    Science.gov (United States)

    Haas, Thorsten; Fries, Dietmar; Holz, Carmen; Innerhofer, Petra; Streif, Werner; Klingler, Anton; Hanke, Alexander; Velik-Salchner, Corinna

    2008-04-01

    Small-volume resuscitation using hypertonic saline/hydroxyethyl starch 200/0.62 (HS-HES) has been shown to be an effective alternative to the administration of crystalloids or colloids in trauma patients. All i.v. fluids cause dose-related dilutional coagulopathy and show intrinsic effects on the hemostatic system, but only few data refer to functional consequences after small-volume resuscitation. Using thrombelastometry (ROTEM), we studied 30 pigs (weighing 35-45 kg) after withdrawal of 60% of blood volume [1484 mL (1369-1624 mL)] and receiving 4 mL/kg HS-HES for compensation of blood loss or 4% gelatin or 6% HES 130/0.4 in a 1:1 ratio to lost blood volume. To compare the ROTEM variables (coagulation time, clot formation time, alpha angle, clot firmness, and fibrinogen polymerization) with bleeding tendency, a hepatic incision was made and blood loss was measured. Median (25th, 75th percentile) fibrinogen polymerization was significantly higher after HS-HES infusion [11 mm (10, 11), P = 0.0034] when compared with administration of 4% gelatin [4.5 mm (3.0, 5.8)] or HES 130/0.4 [3.5 mm (2.3, 4.0)]. Median blood loss after liver incision was 725 mL (900, 375) after HS-HES, 1625 mL (1275, 1950) after 4% gelatin, and 1600 mL (1500, 1800) after 6% HES 130/0.4 (P = 0.004). Hemodynamic stabilization was traceable in all groups but showed differences regarding filling pressures. Resuscitation from hemorrhagic shock with HS-HES 200/0.62 results in less impairment of clot formation when compared with compensation of blood loss by administering 6% HES 130/0.4 or 4% gelatin.

  5. Membrane diffusion- and capillary blood volume measurements are not useful as screening tools for pulmonary arterial hypertension in systemic sclerosis: a case control study

    Directory of Open Access Journals (Sweden)

    Spreeuwenberg Marieke D

    2008-10-01

    Full Text Available Abstract Background There is no optimal screening tool for the assessment of pulmonary arterial hypertension (PAH in patients with systemic sclerosis (SSc. A decreasing transfer factor of the lung for CO (TLCO is associated with the development of PAH in SSc. TLCO can be partitioned into the diffusion of the alveolar capillary membrane (Dm and the capillary blood volume (Vc. The use of the partitioned diffusion to detect PAH in SSc is not well established yet. This study evaluates whether Dm and Vc could be candidates for further study of the use for screening for PAH in SSc. Methods Eleven SSc patients with PAH (SScPAH+, 13 SSc patients without PAH (SScPAH- and 10 healthy control subjects were included. Pulmonary function testing took place at diagnosis of PAH. TLCO was partitioned according to Roughton and Forster. As pulmonary fibrosis in SSc influences values of the (partitioned TLCO, these were adjusted for fibrosis score as assessed on HRCT. Results TLCO as percentage of predicted (% was lower in SScPAH+ than in SScPAH- (41 ± 7% vs. 63 ± 12%, p vs. 39 ± 12%, p Conclusion SScPAH+ patients have lower Dm% than SScPAH- patients. There are no correlations between Dm% and hemodynamic parameters of PAH in SScPAH+. These findings do not support further study of the role of partitioning TLCO in the diagnostic work- up for PAH in SSc.

  6. Effect of steroid on brain tumors and surround edemas : observation with regional cerebral blood volume (rCBV) maps of perfusion MRI

    International Nuclear Information System (INIS)

    Choi, Ju Youl; Sun, Joo Sung; Kim, Sun Yong; Kim, Ji Hyung; Suh, Jung Ho; Cho, Kyung Gi; Kim, Jang Sung

    2000-01-01

    To observe the hemodynamic change in brain tumors and peritumoral edemas after steroid treatment, and then investigate the clinical usefulness of perfusion MRI. We acquired conventional and perfusion MR images in 15 patients with various intracranial tumors (4 glioblastoma multiformes, 4 meningiomas, 3 metastatic tumors, 1 anaplastic ependymoma, 1 anaplastic astrocytoma, 1 hemangioblastoma, and 1 pilocytic astrocytoma). For perfusion MR imaging, a 1.5T unit employing the gradient-echo EPI technique was used, and further perfusion MR images were obtained 2-10 days after intravenous steroid therapy. After processing of the raw data, regional cerebral blood volume (rCBV) maps were reconstructed. The maps were visually evaluated by comparing relative perfusion in brain tumors and peritumoral edemas with that in contralateral white matter. Objective evaluations were performed by comparing the perfusion ratios of brain tumors and peritumoral edemas. Visual evaluations of rCBV maps, showed that in most brain tumors (67%, 10/15), perfusion was high before steroid treatment and showed in (80%, 12/15) decreased afterwards. Objective evaluation, showed that in all brain tumors, perfusion decreased. Visual evaluation of perfusion change in peritumoral edemas revealed change in only one case, but objective evaluation indicated that perfusion decreased significantly in all seven cases. rCBV maps acquired by perfusion MR imaging can provide hemodynamic information about brain tumors and peritumoral edemas. Such maps could prove helpful in the preoperative planning of brain tumor surgery and the monitoring of steroid effects during conservative treatment. (author)

  7. Amide proton transfer imaging to discriminate between low- and high-grade gliomas: added value to apparent diffusion coefficient and relative cerebral blood volume

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yoon Seong; Ahn, Sung Soo; Lee, Seung-Koo [Yonsei University College of Medicine, Department of Radiology and Research Institute of Radiological Science, College of Medicine, Seoul (Korea, Republic of); Chang, Jong Hee; Kang, Seok-Gu [Yonsei University College of Medicine, Department of Neurosurgery, Seoul (Korea, Republic of); Kim, Se Hoon [Yonsei University College of Medicine, Department of Pathology, Seoul (Korea, Republic of); Zhou, Jinyuan [Johns Hopkins University School of Medicine, Division of MRI Research, Department of Radiology, Baltimore, MD (United States)

    2017-08-15

    To evaluate the added value of amide proton transfer (APT) imaging to the apparent diffusion coefficient (ADC) from diffusion tensor imaging (DTI) and the relative cerebral blood volume (rCBV) from perfusion magnetic resonance imaging (MRI) for discriminating between high- and low-grade gliomas. Forty-six consecutive adult patients with diffuse gliomas who underwent preoperative APT imaging, DTI and perfusion MRI were enrolled. APT signals were compared according to the World Health Organization grade. The diagnostic ability and added value of the APT signal to the ADC and rCBV for discriminating between low- and high-grade gliomas were evaluated using receiver operating characteristic (ROC) analyses and integrated discrimination improvement. The APT signal increased as the glioma grade increased. The discrimination abilities of the APT, ADC and rCBV values were not significantly different. Using both the APT signal and ADC significantly improved discrimination vs. the ADC alone (area under the ROC curve [AUC], 0.888 vs. 0.910; P = 0.007), whereas using both the APT signal and rCBV did not improve discrimination vs. the rCBV alone (AUC, 0.927 vs. 0.923; P = 0.222). APT imaging may be a useful imaging biomarker that adds value to the ADC for discriminating between low- and high-grade gliomas. (orig.)

  8. Improvements in the Quantitative Assessment of Cerebral Blood Volume and Flow with the Removal of Vessel Voxels from MR Perfusion Images

    Directory of Open Access Journals (Sweden)

    Michael Mu Huo Teng

    2013-01-01

    Full Text Available Objective. To improve the quantitative assessment of cerebral blood volume (CBV and flow (CBF in the brain voxels from MR perfusion images. Materials and Methods. Normal brain parenchyma was automatically segmented with the time-to-peak criteria after cerebrospinal fluid removal and preliminary vessel voxel removal. Two scaling factors were calculated by comparing the relative CBV and CBF of the segmented normal brain parenchyma with the absolute values in the literature. Using the scaling factors, the relative values were converted to the absolute CBV and CBF. Voxels with either CBV > 8 mL/100 g or CBF > 100 mL/100 g/min were characterized as vessel voxels and were excluded from the quantitative measurements. Results. The segmented brain parenchyma with normal perfusion was consistent with the angiographic findings for each patient. We confirmed the necessity of dual thresholds including CBF and CBV for proper removal of vessel voxels. The scaling factors were 0.208 ± 0.041 for CBV, and 0.168 ± 0.037, 0.172 ± 0.037 for CBF calculated using standard and circulant singular value decomposition techniques, respectively. Conclusion. The automatic scaling and vessel removal techniques provide an alternative method for obtaining improved quantitative assessment of CBV and CBF in patients with thromboembolic cerebral arterial disease.

  9. Intrinsic optical signal imaging of the blood volume changes is sufficient for mapping the resting state functional connectivity in the rodent cortex

    Science.gov (United States)

    Kura, Sreekanth; Xie, Hongyu; Fu, Buyin; Ayata, Cenk; Boas, David A.; Sakadžić, Sava

    2018-06-01

    Objective. Resting state functional connectivity (RSFC) allows the study of functional organization in normal and diseased brain by measuring the spontaneous brain activity generated under resting conditions. Intrinsic optical signal imaging (IOSI) based on multiple illumination wavelengths has been used successfully to compute RSFC maps in animal studies. The IOSI setup complexity would be greatly reduced if only a single wavelength can be used to obtain comparable RSFC maps. Approach. We used anesthetized mice and performed various comparisons between the RSFC maps based on single wavelength as well as oxy-, deoxy- and total hemoglobin concentration changes. Main results. The RSFC maps based on IOSI at a single wavelength selected for sensitivity to the blood volume changes are quantitatively comparable to the RSFC maps based on oxy- and total hemoglobin concentration changes obtained by the more complex IOSI setups. Moreover, RSFC maps do not require CCD cameras with very high frame acquisition rates, since our results demonstrate that they can be computed from the data obtained at frame rates as low as 5 Hz. Significance. Our results will have general utility for guiding future RSFC studies based on IOSI and making decisions about the IOSI system designs.

  10. Nanoscale interfacial defect shedding in a growing nematic droplet.

    Science.gov (United States)

    Gurevich, Sebastian; Provatas, Nikolas; Rey, Alejandro

    2017-08-01

    Interfacial defect shedding is the most recent known mechanism for defect formation in a thermally driven isotropic-to-nematic phase transition. It manifests in nematic-isotropic interfaces going through an anchoring switch. Numerical computations in planar geometry established that a growing nematic droplet can undergo interfacial defect shedding, nucleating interfacial defect structures that shed into the bulk as +1/2 point defects. By extending the study of interfacial defect shedding in a growing nematic droplet to larger length and time scales, and to three dimensions, we unveil an oscillatory growth mode involving shape and anchoring transitions that results in a controllable regular distributions of point defects in planar geometry, and complex structures of disclination lines in three dimensions.

  11. Resveratrol Improves Tube Formation in AGE-Induced Late Endothelial Progenitor Cells by Suppressing Syndecan-4 Shedding

    Directory of Open Access Journals (Sweden)

    Han Wu

    2018-01-01

    Full Text Available Dysfunction of endothelial progenitor cells (EPCs contributes to cardiovascular complications in diabetes, and resveratrol has been shown to improve EPC functions. Syndecan-4 (Synd4, a cell surface heparin sulfate proteoglycan, has been shown to promote neovascularization. Thus, the present study was performed to determine whether resveratrol promoted angiogenesis of EPCs by regulating Synd4. Late EPCs were isolated from human peripheral blood and stimulated with AGEs. Western blot showed that AGEs induced Synd4 shedding in a dose- and time-dependent manner. AGE-induced Synd4 shedding was partly reversed by NAC or resveratrol, along with normalized ROS production. Overexpression of Synd4 or pretreatment of resveratrol reversed AGE-impaired tube formation of EPCs and regulated the Akt/eNOS pathway. Furthermore, resveratrol suppressed Synd4 shedding via the inhibition of oxidative stress and improved tube formation of late EPCs via the regulation of the Synd4/Akt/eNOS pathway.

  12. Counter and Complicit Masculine Discourse Among Men's Shed Members.

    Science.gov (United States)

    Mackenzie, Corey S; Roger, Kerstin; Robertson, Steve; Oliffe, John L; Nurmi, Mary Anne; Urquhart, James

    2017-07-01

    Men's Sheds is a growing international movement aimed at providing men with places and activities that facilitate social connectedness. Despite Men's Sheds' focus on males, little attention has been paid to masculinities within the specific context of these settings. The current study used a gender relations framework to explore the ways in which attendees discussed Men's Sheds, with particular attention to discussions that were complicit and counter to traditional, hegemonic views of masculinity, and diverse positions in between these binaries. The data consisted of transcripts and field notes from four focus groups comprising mostly older, White, retired male members of a Canadian shed ( N = 22). The analysis revealed three overall themes: (1) focus on work, (2) independence, and (3) need for male-focused spaces. These themes and associated subthemes suggest that shed members ascribe to dominant masculine values and ideals, but also support more fluid and flexible views of masculinity. Implications are discussed for how working with an array of masculinities within the Men's Sheds movement will be helpful with respect to their future growth in Canada and internationally.

  13. Capacity building in indigenous men's groups and sheds across Australia.

    Science.gov (United States)

    Southcombe, Amie; Cavanagh, Jillian; Bartram, Timothy

    2015-09-01

    This article presents an investigation into capacity building, at the community level, in Aboriginal and Torres Strait Islander Men's Groups and Sheds. As safe men's spaces, Men's Groups and Sheds represent an ever-growing social, and health and well-being community service across Australia. The study is qualitative and employs 'yarning circles' (focus groups), semi-structured interviews and observations to gather data from 15 Groups/Sheds involving 45 men from urban, regional and remote communities. We found that capacity building is primarily about securing relationships between Group Leaders/Shed Co-ordinators and Government services. Capacity building establishes links to services such as Centrelink, Medicare, Department of Housing, Probation and Control, and positive outcomes such as Indigenous men securing housing and Centrelink payments. Capacity building results in better health outcomes and, educates and empowers men to improve their social, cultural, emotional and economic well-being. It helps men to better connect with family and community. The current research paves the way for countries worldwide to explore the conceptual and empirical approach of capacity building applicable to other Indigenous [and non-Indigenous] Men's Groups/Sheds. We recommend feasibilities studies, on approaches to capacity building in Indigenous Groups/Sheds, be carried out within urban, regional and remote regions across the country. © The Author (2014). Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Circadian disc shedding in Xenopus retina in vitro

    International Nuclear Information System (INIS)

    Flannery, J.G.; Fisher, S.K.

    1984-01-01

    To further examine the endogenous rhythm of disc shedding and phagocytosis observed in several species, adult Xenopus were entrained to a 12 hr light/12 hr dark cycle and then placed in constant darkness. At various times during a 3-day period of constant darkness, eyes were explanted and placed into culture medium, then processed for light and electron microscopy. A clear rhythmicity of disc shedding was observed, with pronounced peaks at the times light onset occurred in the original entrainment cycle. Modification of the HCO 3 - ion concentration in the medium was found to raise the amplitude of the peak of endogenous disc shedding. Explants maintained in culture medium containing deuterium oxide (a compound known to perturb circadian oscillators) were found to shed with a longer interval between peaks. The addition of the protein synthesis inhibitor, anisomycin, to this preparation suppressed the shedding rhythm. The action of anisomycin was investigated by autoradiographic examination of the pattern of 3 H-leucine uptake and protein synthesis by the explant. The findings suggest the presence of a circadian oscillator for rhythmic disc shedding within the amphibian eye

  15. Experimental feline enteric coronavirus infection reveals an aberrant infection pattern and shedding of mutants with impaired infectivity in enterocyte cultures

    Science.gov (United States)

    Desmarets, Lowiese M. B.; Vermeulen, Ben L.; Theuns, Sebastiaan; Conceição-Neto, Nádia; Zeller, Mark; Roukaerts, Inge D. M.; Acar, Delphine D.; Olyslaegers, Dominique A. J.; Van Ranst, Marc; Matthijnssens, Jelle; Nauwynck, Hans J.

    2016-01-01

    Feline infectious peritonitis (FIP) results from mutations in the viral genome during a common feline enteric coronavirus (FECV) infection. Since many virological and immunological data on FECV infections are lacking, the present study investigated these missing links during experimental infection of three SPF cats with FECV strain UCD. Two cats showed mild clinical signs, faecal shedding of infectious virus from 4 dpi, a cell-associated viraemia at inconsistent time points from 5 dpi, a highly neutralising antibody response from 9 dpi, and no major abnormalities in leukocyte numbers. Faecal shedding lasted for 28–56 days, but virus shed during this stage was less infectious in enterocyte cultures and affected by mutations. Remarkably, in the other cat neither clinical signs nor acute shedding were seen, but virus was detected in blood cells from 3 dpi, and shedding of non-enterotropic, mutated viruses suddenly occurred from 14 dpi onwards. Neutralising antibodies arose from 21 dpi. Leukocyte numbers were not different compared to the other cats, except for the CD8+ regulatory T cells. These data indicate that FECV can infect immune cells even in the absence of intestinal replication and raise the hypothesis that the gradual adaptation to these cells can allow non-enterotropic mutants to arise. PMID:26822958

  16. Evaluation of right ventricular function using gated equilibrium blood pool radionuclide ventriculography in patients with congenital volume and pressure overload late after surgical repair

    International Nuclear Information System (INIS)

    Hirata, Nobuaki; Sakakibara, Tetsuo; Watanabe, Shinichiro; Nomura, Fumikazu; Akamatsu, Hiroki; Matsumura, Yasushi; Yamamoto, Kazuhiro; Sasaki, Jiro; Kodama, Kazuhisa

    1991-01-01

    The effects of congenital right ventricular pressure and volume overload were studied in 3 patients with pulmonary stenosis, 7 with atrial septal defect and 6 with atrial septal defect plus pulmonary stenosis late after successful surgical correction. Gated equilibrium blood pool radionuclide ventriculography was used to measure right ventricular function at rest and during exercise and to compare it with eight normal subjects. Right ventricular ejection fractions at rest and during exercise were measured to be 61±9% and 66±13%, respectively, in the group with pulmonary stenosis, 49±7% and 54±8% in the group with atrial septal defect, and 65±13% and 69±13% in the group with atrial septal defect plus pulmonary stenosis. The values in the groups with pulmonary stenosis and atrial septal defect plus pulmonary stenosis were significantly higher than the control subjects (45±5% and 51±5%, p<0.01). The peak filling rate at rest and during exercise was also significantly higher in the groups with pulmonary stenosis and atrial septal defect plus pulmonary stenosis than in controls (at rest, 2.72±0.72, 2.53±0.94 vs. 1.64±0.24 p<0.05; during exercise, 4.38±1.23, 4.13±1.18 vs. 2.25±0.62, p<0.01). When patients with right ventricular systolic pressure equal to or greater than left ventricular systolic pressure and those with right ventricular systolic pressure less than left ventricular systolic pressure were compared, the right ventricular ejection fraction and peak filling rate were greater with the higher pressure at rest (71±10% and 3.12±0.81% vs. 55±3% and 2.30±0.27, p<0.05) and during exercise (75±11% and 4.86±1.01 vs. 59±3% and 2.61±0.35, p<0.05). Postoperative right ventricular hyperfunction may be due to preoperative pressure, but not volume, overload. (author)

  17. Experimental Investigation of Vortex Shedding in High Reynolds Number Flow Over Compressor Blades in Cascade

    National Research Council Canada - National Science Library

    Lim, Choon

    2003-01-01

    .... Vortex shedding was determined to be a leading edge phenomenon as periodic shedding was only detected on the pressure side of the wake, The relationship between vortex shedding frequency and Reynolds...

  18. Investigation of cognitive circuits using steady-state cerebral blood volume and diffusion tensor imaging in patients with mild cognitive impairment following electrical injury

    International Nuclear Information System (INIS)

    Park, Chang-hyun; Seo, Cheong Hoon; Joo, So Young; Jung, Myung Hun; Jang, Soyeon; Lee, Ho Young; Ohn, Suk Hoon

    2017-01-01

    We utilized cerebral blood volume (CBV) magnetic resonance imaging and diffusion tensor imaging (DTI) to investigate changes in cognitive networks in patients experiencing cognitive dysfunction following electrical injury. Cognitive function was assessed across various domains, including attention, verbal memory, executive function, and language. Depressive symptoms were also evaluated. CBV maps and DTI measures were obtained from 24 patients (age, 41.8 ± 5.8 years; education, 13.3 ± 1.9 years) and 24 healthy controls (age, 42.3 ± 2.7 years; education, 14.3 ± 1.9 years). CBV maps and DTI measures were compared between patients and controls, and correlations between these measures and each cognitive assessment score were examined. Patients exhibited lower attention, verbal memory, and executive function scores than controls (all p < 0.01). Patients also exhibited higher depression scores than controls (p < 0.01), as well as a predominant increase in CBV in the cerebellar vermis relative to that of controls (height p < uncorrected 0.001, extent p < corrected 0.05). Correlation analyses revealed a strong association between executive function scores and CBV in the bilateral posterior cingulate cortex and left mammillary body in patients (height p < uncorrected 0.001, extent p < corrected 0.05). There were no significant differences in DTI measures between patients and controls. The CBV maps showed hypermetabolism in the cerebello-limbic system; DTI did not find any microstructural changes. Our results suggest that patients experiencing cognitive dysfunction following electrical injury may possess a cognitive reserve that protects against deteriorating conditions such as dementia. (orig.)

  19. Regional cerebral blood volume (rCBV) in the cerebral and cerebellar hemispheres in nomal 52 healthy adults. Measurement with contrast-enhanced dynamic echo-planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Muroi, Kenzo; Kurihara, Hiroaki; Amauchi, Hiroshi; Nozawa, Takeo; Matsubara, Sho; Yamamoto, Isao [Yokohama City Univ. (Japan). Hospital; Iwasawa, Tae

    2001-05-01

    The aim of this study was to investigate the possibility of absolute quantification of mean transit time (MTT) and rCBV in normal 52 healthy adults using contrast-enhanced dynamic echo-planar imaging, changes in signals in the middle cerebral arteries (MCAs) in the Sylvian fissures as AIF. MR was performed with a 1.5 T magnet (Horizon, GE Medical System, Milwaukee, WI). Dynamic susceptibility contrast-enhanced imaging was obtained every 1.8 second using echo-planar imaging (EPI) sequence (TE=42 msec, matrices=128 x 128) in six slices (6 mm slice thickness with 10 mm gap) including the cerebellar hemisphere at the level of middle cerebellar peduncles. The regional cerebral blood volume (rCBV) was calculated based on dilution theory. We calculated rCBV of the cerebral white matter (WM), cortical gray matter (GM), and cerebellar hemispheres (CH), and the effect of age on MTT and rCBV were evaluated linear regression analyses. The MTT of MCAs did not change with age, and the area under the curve of MCAs declined slightly with age. The mean rCBV of cortical GM, cerebral WM and cerebellar hemispheres were 8.2{+-}2.8, 2.0{+-}0.8 and 8.8{+-}2.1 respectively. The rCBV of cortical GM and the CH decreased slightly with age, however, that of WM remained to be a greater extent than those in GM. From these results, the method using AIF determined in bilateral MCAs was considered as an practical approach for the quantification of rCBV. Further clinical and/or comparative studies with other modalities will be necessary for the application of this method for patients with atherosclerosis and/or major vessel occlusion. (author)

  20. Effects of 5-hydroxymethyl-2-furfural on the volume and membrane permeability of red blood cells from patients with sickle cell disease

    Science.gov (United States)

    Hannemann, Anke; Cytlak, Urszula M; Rees, David C; Tewari, Sanjay; Gibson, John S

    2014-01-01

    The heterocyclic aldehyde 5-hydroxymethyl-2-furfural (5HMF) interacts allosterically with the abnormal form of haemoglobin (Hb), HbS, in red blood cells (RBCs) from patients with sickle cell disease (SCD), thereby increasing oxygen affinity and decreasing HbS polymerization and RBC sickling during hypoxia. We hypothesized that should 5HMF also inhibit the main cation pathways implicated in the dehydration of RBCs from SCD patients – the deoxygenation-induced cation pathway (Psickle), the Ca2+-activated K+ channel (the Gardos channel) and the K+–Cl− cotransporter (KCC) – it would have a synergistic effect in protection against sickling, directly through interacting with HbS, and indirectly through maintaining hydration and reducing [HbS]. This study was therefore designed to investigate the effects of 5HMF on RBC volume and K+ permeability in vitro. 5HMF markedly reduced the deoxygenation-induced dehydration of RBCs whether in response to maintained deoxygenation or to cyclical deoxygenation/re-oxygenation. 5HMF was found to inhibit Psickle, an effect which correlated with its effects on sickling. Deoxygenation-induced activation of the Gardos channel and exposure of phosphatidylserine were also inhibited, probably indirectly via reduced entry of Ca2+ through the Psickle pathway. Effects of 5HMF on KCC were more modest with a slight inhibition in N-ethylmaleimide (NEM, 1 mm)-treated RBCs and stimulation in RBCs untreated with NEM. These findings support the hypothesis that 5HMF may also be beneficial through effects on RBC ion and water homeostasis. PMID:25015917

  1. Improved target volume definition in radiosurgery of arteriovenous malformations by stereotactic correlation of MRA, MRI, blood bolus tagging, and functional MRI

    International Nuclear Information System (INIS)

    Schad, L.R.; Bock, M.; Baudendistel, K.; Essig, M.; Debus, J.; Knopp, M.V.; Engenhart, R.; Lorenz, W.J.

    1996-01-01

    The authors report the sterotactic correlation of different MRI-techniques [MR angiography (MRA), MRI, blood bolus tagging (STAR), and functional MRI] in 10 patients with cerebral arteriovenous malformations (AVM) and its application in precision radiotherapy planning. The patient's head was fixed in a stereotactic localization system. By phantom measurements different materials (steel, aluminium, titanium, plastic, wood, ceramics) used for the stereotactic system were tested for mechanical stability and geometrical MR image distortion. All metallic stereotactic rings led to a more or less dramatic geometrical distortion and signal cancellation in the MR images. The best properties - nearly no distortion and high mechanical stability - are provided by a ceramic ring. If necessary, the remaining geometrical MR image distortion can be 'corrected' by calculations based on modeling the distortion as a fourth-order 2D-polynomial. Using this method multimodality matching can be performed automatically as long as all images are acquired in the same examination and the patient is sufficiently immobilized. Precise definition of the target volume could be performed by the radiotherapist either directly in MR images or in calculated projection MR angiograms. As a result, information about the hemodynamics of the AVM was provided by a 3D-phase-contrast flow measurement and a dynamic MRA with the STAR technique leading to an improved definition of the size of the nidus, and the pattern of the venous drainage. In addition, functional MRI was performed in patients with lesions close to the primary motor cortex area leading to an improved definition of structures at risk for high-dose application in radiosurgery. (orig./MG)

  2. Differentiating between Glioblastoma and Primary CNS Lymphoma Using Combined Whole-tumor Histogram Analysis of the Normalized Cerebral Blood Volume and the Apparent Diffusion Coefficient.

    Science.gov (United States)

    Bao, Shixing; Watanabe, Yoshiyuki; Takahashi, Hiroto; Tanaka, Hisashi; Arisawa, Atsuko; Matsuo, Chisato; Wu, Rongli; Fujimoto, Yasunori; Tomiyama, Noriyuki

    2018-05-31

    This study aimed to determine whether whole-tumor histogram analysis of normalized cerebral blood volume (nCBV) and apparent diffusion coefficient (ADC) for contrast-enhancing lesions can be used to differentiate between glioblastoma (GBM) and primary central nervous system lymphoma (PCNSL). From 20 patients, 9 with PCNSL and 11 with GBM without any hemorrhagic lesions, underwent MRI, including diffusion-weighted imaging and dynamic susceptibility contrast perfusion-weighted imaging before surgery. Histogram analysis of nCBV and ADC from whole-tumor voxels in contrast-enhancing lesions was performed. An unpaired t-test was used to compare the mean values for each type of tumor. A multivariate logistic regression model (LRM) was performed to classify GBM and PCNSL using the best parameters of ADC and nCBV. All nCBV histogram parameters of GBMs were larger than those of PCNSLs, but only average nCBV was statistically significant after Bonferroni correction. Meanwhile, ADC histogram parameters were also larger in GBM compared to those in PCNSL, but these differences were not statistically significant. According to receiver operating characteristic curve analysis, the nCBV average and ADC 25th percentile demonstrated the largest area under the curve with values of 0.869 and 0.838, respectively. The LRM combining these two parameters differentiated between GBM and PCNSL with a higher area under the curve value (Logit (P) = -21.12 + 10.00 × ADC 25th percentile (10 -3 mm 2 /s) + 5.420 × nCBV mean, P histogram analysis of nCBV and ADC combined can be a valuable objective diagnostic method for differentiating between GBM and PCNSL.

  3. Reliability of perfusion MR imaging in symptomatic carotid occlusive disease. Cerebral blood volume, mean transit time and time-to-peak

    International Nuclear Information System (INIS)

    Kim, J.H.; Lee, E.J.; Lee, S.J.; Choi, N.C.; Lim, B.H.; Shin, T.

    2002-01-01

    Purpose: Perfusion MR imaging offers an easy quantitative evaluation of relative regional cerebral blood volume (rrCBV), relative mean transit time (rMTT) and time-to-peak (TTP). The purpose of this study was to investigate the reliability of these parameters in assessing the hemodynamic disturbance of carotid occlusive disease in comparison with normative data. Material and Methods: Dynamic contrast-enhanced T2*-weighted perfusion MR imaging was performed in 19 patients with symptomatic unilateral internal carotid artery occlusion and 20 control subjects. The three parameters were calculated from the concentration-time curve fitted by gamma-variate function. Lesion-to-contralateral ratios of each parameter were compared between patients and control subjects. Results: Mean±SD of rrCBV, rMTT and TTP ratios of patients were 1.089±0.118, 1.054±0.031 and 1.062±0.039, respectively, and those of control subjects were 1.002±0.045, 1.000±0.006, 1.001±0.006, respectively. The rMTT and TTP ratios of all patients were greater than 2SDs of control data, whereas in only 6 patients (32%), rrCBV ratios were greater than 2SDs of control data. The three parameter ratios of the patients were significantly high compared with those of control subjects, respectively (p<0.01 for rrCBV ratios, p<0.0001 for rMTT ratios, and p<0.0001 for TTP ratios). Conclusion: Our results indicate that rMTT and TTP of patients, in contrast to rrCBV, are distributed in narrow ranges minimally overlapped with control data. The rMTT and TTP could be more reliable parameters than rrCBV in assessing the hemodynamic disturbance in carotid occlusive disease

  4. Effects of 5-hydroxymethyl-2-furfural on the volume and membrane permeability of red blood cells from patients with sickle cell disease.

    Science.gov (United States)

    Hannemann, Anke; Cytlak, Urszula M; Rees, David C; Tewari, Sanjay; Gibson, John S

    2014-09-15

    The heterocyclic aldehyde 5-hydroxymethyl-2-furfural (5HMF) interacts allosterically with the abnormal form of haemoglobin (Hb), HbS, in red blood cells (RBCs) from patients with sickle cell disease (SCD), thereby increasing oxygen affinity and decreasing HbS polymerization and RBC sickling during hypoxia. We hypothesized that should 5HMF also inhibit the main cation pathways implicated in the dehydration of RBCs from SCD patients - the deoxygenation-induced cation pathway (Psickle), the Ca(2+)-activated K(+) channel (the Gardos channel) and the K(+)-Cl(-) cotransporter (KCC) - it would have a synergistic effect in protection against sickling, directly through interacting with HbS, and indirectly through maintaining hydration and reducing [HbS]. This study was therefore designed to investigate the effects of 5HMF on RBC volume and K(+) permeability in vitro. 5HMF markedly reduced the deoxygenation-induced dehydration of RBCs whether in response to maintained deoxygenation or to cyclical deoxygenation/re-oxygenation. 5HMF was found to inhibit Psickle, an effect which correlated with its effects on sickling. Deoxygenation-induced activation of the Gardos channel and exposure of phosphatidylserine were also inhibited, probably indirectly via reduced entry of Ca(2+) through the Psickle pathway. Effects of 5HMF on KCC were more modest with a slight inhibition in N-ethylmaleimide (NEM, 1 mm)-treated RBCs and stimulation in RBCs untreated with NEM. These findings support the hypothesis that 5HMF may also be beneficial through effects on RBC ion and water homeostasis. © 2014 The Authors. The Journal of Physiology © 2014 The Physiological Society.

  5. Investigation of cognitive circuits using steady-state cerebral blood volume and diffusion tensor imaging in patients with mild cognitive impairment following electrical injury

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chang-hyun [Catholic University of Korea, Department of Psychiatry, College of Medicine, Seoul (Korea, Republic of); Seo, Cheong Hoon; Joo, So Young [Hallym University College of Medicine, Department of Physical Medicine and Rehabilitation, Hangang Sacred Heart Hospital, Seoul (Korea, Republic of); Jung, Myung Hun [Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Department of Psychiatry, Dongan-gu Anyang, Gyeonggi-do (Korea, Republic of); Jang, Soyeon; Lee, Ho Young; Ohn, Suk Hoon [Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Department of Physical Medicine and Rehabilitation, Dongan-gu Anyang, Gyeonggi-do (Korea, Republic of)

    2017-09-15

    We utilized cerebral blood volume (CBV) magnetic resonance imaging and diffusion tensor imaging (DTI) to investigate changes in cognitive networks in patients experiencing cognitive dysfunction following electrical injury. Cognitive function was assessed across various domains, including attention, verbal memory, executive function, and language. Depressive symptoms were also evaluated. CBV maps and DTI measures were obtained from 24 patients (age, 41.8 ± 5.8 years; education, 13.3 ± 1.9 years) and 24 healthy controls (age, 42.3 ± 2.7 years; education, 14.3 ± 1.9 years). CBV maps and DTI measures were compared between patients and controls, and correlations between these measures and each cognitive assessment score were examined. Patients exhibited lower attention, verbal memory, and executive function scores than controls (all p < 0.01). Patients also exhibited higher depression scores than controls (p < 0.01), as well as a predominant increase in CBV in the cerebellar vermis relative to that of controls (height p < uncorrected 0.001, extent p < corrected 0.05). Correlation analyses revealed a strong association between executive function scores and CBV in the bilateral posterior cingulate cortex and left mammillary body in patients (height p < uncorrected 0.001, extent p < corrected 0.05). There were no significant differences in DTI measures between patients and controls. The CBV maps showed hypermetabolism in the cerebello-limbic system; DTI did not find any microstructural changes. Our results suggest that patients experiencing cognitive dysfunction following electrical injury may possess a cognitive reserve that protects against deteriorating conditions such as dementia. (orig.)

  6. CRISP. Intelligent load shedding. Deliverable 1.5

    International Nuclear Information System (INIS)

    Gajic, Z.; Karlsson, D.; Ullah, N.R.; Okuboye, S.; Andrieu, C.; Carlsson, P.

    2005-08-01

    Load shedding has been used to mitigate the consequences of large disturbances in electric power systems, since the beginning of the electrification era. The way to execute the load shedding, i.e. open a circuit breaker, has hardly developed at all for a 100-year period. The modern society dependence on reliable electricity supply is continuously increasing. This means that the consequences of traditional load shedding are not acceptable. In the meantime computer and communication technology has developed tremendously. There is also a trend to use more and more intelligent control and less hardware, such as lines and generators, to provide the required level of reliability for the electric supply. Especially in power systems, and parts of power systems, comprising distributed generation, there seems to be a great potential to improve the overall cost/benefit-ratio for the desired level of reliability, by the use of intelligent load shedding. Intelligent load shedding is a means to improve power system stability, by providing an adapted load control along the distribution network, in situations where the power system otherwise would go unstable. The work with intelligent load shedding in this work package results in various technical principles of dedicated algorithms. These algorithms intend to bring a support tool for the operating system during critical situations. The main aspects are evaluating the right amount and location of power response for a given disturbance, and evaluating the right time response expected in order to comply with an acceptable stability recover. This time response is a main object in order to define appropriate ICT network enabling such a reliable implementation. A main problem of the intelligent load shedding is how to choose load to shed conveniently and quickly. There is a technical problem of finding the right level and location of the load to shed, and also an economical problem of giving incentives in order to have enough remote

  7. Influence of particle shedding from silicone tubing on antibody stability.

    Science.gov (United States)

    Saller, Verena; Hediger, Constanze; Matilainen, Julia; Grauschopf, Ulla; Bechtold-Peters, Karoline; Mahler, Hanns-Christian; Friess, Wolfgang

    2018-05-01

    Peristaltic pumps are increasingly employed during fill & finish operations of a biopharmaceutical drug, due to sensitivity of many biological products to rotary piston pump-related stresses. Yet, possibly also unit operations using peristaltic pumps may shed particulates into the final product due to abrasion from the employed tubing. It was the aim of this study to elucidate the potential influence of particles shed from peristaltic pump tubing on the stability of a drug product. Spiking solutions containing shed silicone particles were prepared via peristaltic pumping of placebo under recirculating conditions and subsequently characterized. Two formulated antibodies were spiked with two realistic, but worst-case levels of particles and a 6-month accelerated stability study with storage at 2-8, 25 and 40°C were conducted. Regarding the formation of aggregates and fragments, both mAbs degraded at their typically expected rates and no additional impact of spiked particles was observed. No changes were discerned however in turbidity, subvisible and visible particle assessments. Flow imaging data for one of the mAb formulations with spiked particles suggested limited colloidal stability of shed particles as indicated by a similar increase in spiked placebo. Shed silicone particles from peristaltic pump tubing are assumed to not impair drug product stability. © 2016 Royal Pharmaceutical Society.

  8. The dynamics of herpesvirus and polyomavirus reactivation and shedding in healthy adults: a 14-month longitudinal study

    Science.gov (United States)

    Ling, Paul D.; Lednicky, John A.; Keitel, Wendy A.; Poston, David G.; White, Zoe S.; Peng, RongSheng; Liu, Zhensheng; Mehta, Satish K.; Pierson, Duane L.; Rooney, Cliona M.; hide

    2003-01-01

    Humans are infected with viruses that establish long-term persistent infections. To address whether immunocompetent individuals control virus reactivation globally or independently and to identify patterns of sporadic reactivation, we monitored herpesviruses and polyomaviruses in 30 adults, over 14 months. Epstein-Barr virus (EBV) DNA was quantitated in saliva and peripheral blood mononuclear cells (PBMCs), cytomegalovirus (CMV) was assayed in urine, and JC virus (JCV) and BK virus (BKV) DNAs were assayed in urine and PBMCs. All individuals shed EBV in saliva, whereas 67% had >or=1 blood sample positive for EBV. Levels of EBV varied widely. CMV shedding occurred infrequently but occurred more commonly in younger individuals (Por=40 years old (P.50). Thus, adults independently control persistent viruses, which display discordant, sporadic reactivations.

  9. Stochastic oscillations induced by vortex shedding in wind

    DEFF Research Database (Denmark)

    Christensen, Claus

    1997-01-01

    As a fluid flows past a circular cylinder,vortices are shed alternately from each side at most values of the Reynolds number. Over a certain range of windspeeds, the periodicity in the wake is synchronized or captured by the mechanical system. The shedding abruptly deviates from the linear Strouhal...... dependence and stays constant at the mechanical natural frequency. This coupling between the velocity field and the motion of the mechanical system is referred to as the lock-in phenomenon. The lock-in phenomenon has importance in structural engineering for slightly damped slender structures exposed to wind...... in the wake is synchronized or captured by the mechanical system. The shedding abruptly deviates from the linear Strouhal dependence and stays constant at the mechanical natural frequency. This coupling between the velocity field and the motion of the mechanical system is referred to as the lock-in phenomenon...

  10. Protoearth mass shedding and the origin of the moon

    Science.gov (United States)

    Boss, A. P.

    1986-01-01

    Darwin's (1980) theory of lunar formation from the earth by means of a rotationally driven dynamic fission instability is presently considered in view of viscous shear's maintenance of solid body rotation throughout the protoearth's accretion phase. Assuming the appropriateness of a polytropic account of the protoearth, it is unlikely that dynamic fission could have occurred; instantaneous spin-up following a giant impact would instead have led to mass shedding. The dynamical phenomenon of mass shedding is here explored on the basis of numerical models for a self-gravitating, axisymmetric, polytropic and dissipative protoearth. It is concluded that mass shedding from the protoearth mantle after a giant impact and explosion could have contributed substantial matter to a lunar disk.

  11. Men's re-placement: Social practices in a Men's Shed.

    Science.gov (United States)

    Anstiss, David; Hodgetts, Darrin; Stolte, Ottilie

    2018-05-06

    Transitions into retirement can be difficult at the best of times. Many men find themselves having to reflect on who they are and what their lives are about. Their access to social supports and material resources are often disrupted. Men's Sheds offer a space where retired men can actively pursue wellbeing, and respond to disruption and loneliness through emplaced community practices. This paper draws on ethnographic research in a Men's Shed in Auckland, New Zealand in order to explore the social practices through which men create a shared space for themselves in which they can engage in meaningful relationships with each other. We document how participants work in concert to create a space in which they can be together through collective labour. Their emplacement in the shed affords opportunities for supported transitions into retirement and for engaging healthy lives beyond paid employment. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. HydroSHEDS: A global comprehensive hydrographic dataset

    Science.gov (United States)

    Wickel, B. A.; Lehner, B.; Sindorf, N.

    2007-12-01

    The Hydrological data and maps based on SHuttle Elevation Derivatives at multiple Scales (HydroSHEDS) is an innovative product that, for the first time, provides hydrographic information in a consistent and comprehensive format for regional and global-scale applications. HydroSHEDS offers a suite of geo-referenced data sets, including stream networks, watershed boundaries, drainage directions, and ancillary data layers such as flow accumulations, distances, and river topology information. The goal of developing HydroSHEDS was to generate key data layers to support regional and global watershed analyses, hydrological modeling, and freshwater conservation planning at a quality, resolution and extent that had previously been unachievable. Available resolutions range from 3 arc-second (approx. 90 meters at the equator) to 5 minute (approx. 10 km at the equator) with seamless near-global extent. HydroSHEDS is derived from elevation data of the Shuttle Radar Topography Mission (SRTM) at 3 arc-second resolution. The original SRTM data have been hydrologically conditioned using a sequence of automated procedures. Existing methods of data improvement and newly developed algorithms have been applied, including void filling, filtering, stream burning, and upscaling techniques. Manual corrections were made where necessary. Preliminary quality assessments indicate that the accuracy of HydroSHEDS significantly exceeds that of existing global watershed and river maps. HydroSHEDS was developed by the Conservation Science Program of the World Wildlife Fund (WWF) in partnership with the U.S. Geological Survey (USGS), the International Centre for Tropical Agriculture (CIAT), The Nature Conservancy (TNC), and the Center for Environmental Systems Research (CESR) of the University of Kassel, Germany.

  13. The Effect of Disinfection on Viability and Function of Baboon Red Blood Cells and Platelets

    Science.gov (United States)

    1997-07-11

    blood cells was evaluated by their ability to transport oxygen as assessed by measurement of 2,3 diphosphoglycerate (DPG)14 and red blood cell p50,15...Blood collected from the bleeding time site (referred to as "shed blood") had a significantly reduced thromboxane A2 level . The ability of the...preserved or treated platelets to increase the shed blood thromboxane A2 level and reduce the 8; extended bleeding time is the measure of their

  14. Neisseria gonorrhoeae co-infection exacerbates vaginal HIV shedding without affecting systemic viral loads in human CD34+ engrafted mice.

    Directory of Open Access Journals (Sweden)

    Stacey X Xu

    Full Text Available HIV synergy with sexually transmitted co-infections is well-documented in the clinic. Co-infection with Neisseria gonorrhoeae in particular, increases genital HIV shedding and mucosal transmission. However, no animal model of co-infection currently exists to directly explore this relationship or to bridge the gap in understanding between clinical and in vitro studies of this interaction. This study aims to test the feasibility of using a humanized mouse model to overcome this barrier. Combining recent in vivo modelling advancements in both HIV and gonococcal research, we developed a co-infection model by engrafting immunodeficient NSG mice with human CD34+ hematopoietic stem cells to generate humanized mice that permit both systemic HIV infection and genital N. gonorrhoeae infection. Systemic plasma and vaginal lavage titres of HIV were measured in order to assess the impact of gonococcal challenge on viral plasma titres and genital shedding. Engrafted mice showed human CD45+ leukocyte repopulation in blood and mucosal tissues. Systemic HIV challenge resulted in 104-105 copies/mL of viral RNA in blood by week 4 post-infection, as well as vaginal shedding of virus. Subsequent gonococcal challenge resulted in unchanged plasma HIV levels but higher viral shedding in the genital tract, which reflects published clinical observations. Thus, human CD34+ stem cell-transplanted NSG mice represent an experimentally tractable animal model in which to study HIV shedding during gonococcal co-infection, allowing dissection of molecular and immunological interactions between these pathogens, and providing a platform to assess future therapeutics aimed at reducing HIV transmission.

  15. Neisseria gonorrhoeae co-infection exacerbates vaginal HIV shedding without affecting systemic viral loads in human CD34+ engrafted mice.

    Science.gov (United States)

    Xu, Stacey X; Leontyev, Danila; Kaul, Rupert; Gray-Owen, Scott D

    2018-01-01

    HIV synergy with sexually transmitted co-infections is well-documented in the clinic. Co-infection with Neisseria gonorrhoeae in particular, increases genital HIV shedding and mucosal transmission. However, no animal model of co-infection currently exists to directly explore this relationship or to bridge the gap in understanding between clinical and in vitro studies of this interaction. This study aims to test the feasibility of using a humanized mouse model to overcome this barrier. Combining recent in vivo modelling advancements in both HIV and gonococcal research, we developed a co-infection model by engrafting immunodeficient NSG mice with human CD34+ hematopoietic stem cells to generate humanized mice that permit both systemic HIV infection and genital N. gonorrhoeae infection. Systemic plasma and vaginal lavage titres of HIV were measured in order to assess the impact of gonococcal challenge on viral plasma titres and genital shedding. Engrafted mice showed human CD45+ leukocyte repopulation in blood and mucosal tissues. Systemic HIV challenge resulted in 104-105 copies/mL of viral RNA in blood by week 4 post-infection, as well as vaginal shedding of virus. Subsequent gonococcal challenge resulted in unchanged plasma HIV levels but higher viral shedding in the genital tract, which reflects published clinical observations. Thus, human CD34+ stem cell-transplanted NSG mice represent an experimentally tractable animal model in which to study HIV shedding during gonococcal co-infection, allowing dissection of molecular and immunological interactions between these pathogens, and providing a platform to assess future therapeutics aimed at reducing HIV transmission.

  16. True progression versus pseudoprogression in the treatment of glioblastomas: a comparison study of normalized cerebral blood volume and apparent diffusion coefficient by histogram analysis.

    Science.gov (United States)

    Song, Yong Sub; Choi, Seung Hong; Park, Chul-Kee; Yi, Kyung Sik; Lee, Woong Jae; Yun, Tae Jin; Kim, Tae Min; Lee, Se-Hoon; Kim, Ji-Hoon; Sohn, Chul-Ho; Park, Sung-Hye; Kim, Il Han; Jahng, Geon-Ho; Chang, Kee-Hyun

    2013-01-01

    The purpose of this study was to differentiate true progression from pseudoprogression of glioblastomas treated with concurrent chemoradiotherapy (CCRT) with temozolomide (TMZ) by using histogram analysis of apparent diffusion coefficient (ADC) and normalized cerebral blood volume (nCBV) maps. Twenty patients with histopathologically proven glioblastoma who had received CCRT with TMZ underwent perfusion-weighted imaging and diffusion-weighted imaging (b = 0, 1000 sec/mm(2)). The corresponding nCBV and ADC maps for the newly visible, entirely enhancing lesions were calculated after the completion of CCRT with TMZ. Two observers independently measured the histogram parameters of the nCBV and ADC maps. The histogram parameters between the true progression group (n = 10) and the pseudoprogression group (n = 10) were compared by use of an unpaired Student's t test and subsequent multivariable stepwise logistic regression analysis to determine the best predictors for the differential diagnosis between the two groups. Receiver operating characteristic analysis was employed to determine the best cutoff values for the histogram parameters that proved to be significant predictors for differentiating true progression from pseudoprogression. Intraclass correlation coefficient was used to determine the level of inter-observer reliability for the histogram parameters. The 5th percentile value (C5) of the cumulative ADC histograms was a significant predictor for the differential diagnosis between true progression and pseudoprogression (p = 0.044 for observer 1; p = 0.011 for observer 2). Optimal cutoff values of 892 × 10(-6) mm(2)/sec for observer 1 and 907 × 10(-6) mm(2)/sec for observer 2 could help differentiate between the two groups with a sensitivity of 90% and 80%, respectively, a specificity of 90% and 80%, respectively, and an area under the curve of 0.880 and 0.840, respectively. There was no other significant differentiating parameter on the nCBV histograms. Inter

  17. Database of normal human cerebral blood flow measured by SPECT. II. Quantification of I-123-IMP studies with ARG method and effects of partial volume correction

    International Nuclear Information System (INIS)

    Inoue, Kentaro; Ito, Hiroshi; Shidahara, Miho

    2006-01-01

    The limited spatial resolution of SPECT causes a partial volume effect (PVE) and can lead to the significant underestimation of regional tracer concentration in the small structures surrounded by a low tracer concentration, such as the cortical gray matter of an atrophied brain. The aim of the present study was to determine, using 123 I-IMP and SPECT, normal cerebral blood flow (CBF) of elderly subjects with and without PVE correction (PVC), and to determine regional differences in the effect of PVC and their association with the regional tissue fraction of the brain. Quantitative CBF SPECT using 123 I-IMP was performed in 33 healthy elderly subjects (18 males, 15 females, 54-74 years old) using the autoradiographic method. We corrected CBF for PVE using segmented MR images, and analyzed quantitative CBF and regional differences in the effect of PVC using tissue fractions of gray matter (GM) and white matter (WM) in regions of interest (ROIs) placed on the cortical and subcortical GM regions and deep WM regions. The mean CBF in GM-ROIs were 31.7±6.6 and 41.0±8.1 ml/100 g/min for males and females, and in WM-ROIs, 18.2±0.7 and 22.9±0.8 ml/100 g/min for males and females, respectively. The mean CBF in GM-ROIs after PVC were 50.9±12.8 and 65.8±16.1 ml/100 g/min for males and females, respectively. There were statistically significant differences in the effect of PVC among ROIs, but not between genders. The effect of PVC was small in the cerebellum and parahippocampal gyrus, and it was large in the superior frontal gyrus, superior parietal lobule and precentral gyrus. Quantitative CBF in GM recovered significantly, but did not reach values as high as those obtained by invasive methods or in the H 2 15 O PET study that used PVC. There were significant regional differences in the effect of PVC, which were considered to result from regional differences in GM tissue fraction, which is more reduced in the frontoparietal regions in the atrophied brain of the elderly

  18. Faecal Campylobacter shedding among dogs in animal shelters across Texas.

    Science.gov (United States)

    Leahy, A M; Cummings, K J; Rodriguez-Rivera, L D; Hamer, S A; Lawhon, S D

    2017-12-01

    Epidemiologic studies on faecal Campylobacter shedding among dogs in the United States have been limited, despite evidence that the incidence of human campylobacteriosis has increased over the last decade. Our objectives were to estimate the prevalence of faecal Campylobacter shedding among shelter dogs in Texas, to estimate the specific prevalence of Campylobacter jejuni and Campylobacter coli shedding, and to identify risk factors for Campylobacter-positive status. Using a cross-sectional study design, we collected faecal samples from dogs in six animal shelters across Texas between May and December, 2014. Quantitative PCR protocols were used to detect Campylobacter in samples and to specifically identify C. jejuni and C. coli. The prevalence of faecal Campylobacter shedding among sampled dogs was 75.7% (140/185). Prevalence varied significantly by shelter (p = .03), ranging from 57% to 93%. There was a marginal association (p = .06) between abnormal faecal consistency and positive Campylobacter status, after controlling for shelter as a random effect. However, approximately 70% of Campylobacter-positive dogs had grossly normal faeces. Campylobacter prevalence did not vary significantly by age group or sex. The prevalence of C. jejuni-positive samples was 5.4% (10/185), but C. coli was not detected in any samples. Dogs are a potential source of zoonotic Campylobacter transmission. © 2017 Blackwell Verlag GmbH.

  19. Developing of the EV charging and parking shed of BIPV

    Institute of Scientific and Technical Information of China (English)

    Wu Shaobo; Wei Chuanchuan; Yu Jiang

    2013-01-01

    Building-integrated photovoltaic (BIPV) is an important application way of solar photovoltaic power. The electric vehicle (EV) charging and parking shed of BIPV is the regeneration energy intellectual integration demonstration application system collection of photovoltaic (PV) grid power,PV off-grid power,EV charging and parking shed,and any part of the functions and their combination will be engaged in practical application on demand. The paper describes the PV shed system structure and design in detail with the present of its actual photos. The shed is 50 m long and 5.5 m wide and capable of parking 18 cars. Under the control of system intellectual con-troller,the power produced by PV from sunlight will charge the parking EV car prior to charging the storage bat-tery,charging the storage battery prior to grid power,grid power at last,and charge the EV by utility grid when it is a cloudy or rainy day.

  20. Circulation shedding in viscous starting flow past a flat plate

    International Nuclear Information System (INIS)

    Nitsche, Monika; Xu, Ling

    2014-01-01

    Numerical simulations of viscous flow past a flat plate moving in the direction normal to itself reveal details of the vortical structure of the flow. At early times, most of the vorticity is attached to the plate. This paper introduces a definition of the shed circulation at all times and shows that it indeed represents vorticity that separates and remains separated from the plate. During a large initial time period, the shed circulation satisfies the scaling laws predicted for self-similar inviscid separation. Various contributions to the circulation shedding rate are presented. The results show that during this initial time period, viscous diffusion of vorticity out of the vortex is significant but appears to be independent of the value of the Reynolds number. At later times, the departure of the shed circulation from its large Reynolds number behaviour is significantly affected by diffusive loss of vorticity through the symmetry axis. A timescale is proposed that describes when the viscous loss through the axis becomes relevant. The simulations provide benchmark results to evaluate simpler separation models such as point vortex and vortex sheet models. A comparison with vortex sheet results is included. (paper)

  1. Replication, pathogenicity, shedding, and transmission of Zaire ebolavirus in pigs.

    Science.gov (United States)

    Kobinger, Gary P; Leung, Anders; Neufeld, James; Richardson, Jason S; Falzarano, Darryl; Smith, Greg; Tierney, Kevin; Patel, Ami; Weingartl, Hana M

    2011-07-15

    (See the editorial commentary by Bausch, on pages 179-81.) Reston ebolavirus was recently detected in pigs in the Philippines. Specific antibodies were found in pig farmers, indicating exposure to the virus. This important observation raises the possibility that pigs may be susceptible to Ebola virus infection, including from other species, such as Zaire ebolavirus (ZEBOV), and can transmit to other susceptible hosts. This study investigated whether ZEBOV, a species commonly reemerging in central Africa, can replicate and induce disease in pigs and can be transmitted to naive animals. Domesticated Landrace pigs were challenged through mucosal exposure with a total of 1 ×10(6) plaque-forming units of ZEBOV and monitored for virus replication, shedding, and pathogenesis. Using similar conditions, virus transmission from infected to naive animals was evaluated in a second set of pigs. Following mucosal exposure, pigs replicated ZEBOV to high titers (reaching 10(7) median tissue culture infective doses/mL), mainly in the respiratory tract, and developed severe lung pathology. Shedding from the oronasal mucosa was detected for up to 14 days after infection, and transmission was confirmed in all naive pigs cohabiting with inoculated animals. These results shed light on the susceptibility of pigs to ZEBOV infection and identify an unexpected site of virus amplification and shedding linked to transmission of infectious virus.

  2. Shedding and seroprevalence of pathogenic Leptospira spp. in sheep and cattle at a New Zealand Abattoir.

    Science.gov (United States)

    Fang, F; Collins-Emerson, J M; Cullum, A; Heuer, C; Wilson, P R; Benschop, J

    2015-06-01

    A cross-sectional study was carried out on sheep and cattle slaughtered at a New Zealand abattoir from September to November 2010 to investigate the supplier-specific shedding rate, renal carriage rate and seroprevalence of leptospires. In the 2008/2009 season, this abattoir experienced three human leptospirosis cases from 20 staff, of which two were hospitalized. Urine, kidney and blood samples were collected from carcasses of 399 sheep (six suppliers, 17 slaughter lines) and 146 cattle (three suppliers, 22 slaughter lines). The urine and kidney samples were tested by quantitative real-time PCR (qPCR), while serum samples (from coagulated blood samples) were tested by microscopic agglutination test (MAT). In total, 27% (73/274; 95% CI: 18-37) of urine samples tested positive by qPCR. Species-specific shedding rates (prevalence of positive urine qPCR) were 31% (95% CI: 17-48) for sheep and 21% (95% CI: 14-30) for cattle. For 545 kidney samples tested, 145 were qPCR positive (27%; 95% CI: 17-39). The average prevalence of kidney qPCR positivity was 29% (95% CI: 17-45) for sheep and 21% (95% CI: 15-28) for cattle. Three hundred and thirty of 542 sampled sheep and cattle had antibodies against Leptospira borgpetersenii serovar Hardjobovis (Hardjobovis) and/or Leptospira interrogans serovar Pomona (Pomona), based on reciprocal MAT titre ≥1 : 48 (overall seroprevalence of 61%; 95% CI: 48-73). Seroprevalence was 57% (95% CI: 40-72) for sheep and 73% (95% CI: 59-83) for cattle. Among the seropositive animals, 41% (70/170; 95% CI: 30-54) were shedding (tested positive by urine qPCR) and 42% (137/330; 95% CI: 30-54) had renal carriage (tested positive by kidney qPCR). Some risk management options for abattoirs or farms to prevent human leptospirosis infections include vaccination of maintenance hosts, the use of personal protective equipment, and the application of urine qPCR to detect shedding status of stock as surveillance and as an alert. © 2014 Blackwell Verlag

  3. Zika Virus Shedding in Semen of Symptomatic Infected Men.

    Science.gov (United States)

    Mead, Paul S; Duggal, Nisha K; Hook, Sarah A; Delorey, Mark; Fischer, Marc; Olzenak McGuire, Dana; Becksted, Heidi; Max, Ryan J; Anishchenko, Michael; Schwartz, Amy M; Tzeng, Wen-Pin; Nelson, Christina A; McDonald, Erin M; Brooks, John T; Brault, Aaron C; Hinckley, Alison F

    2018-04-12

    Zika virus (ZIKV) is an emerging mosquito-borne flavivirus that has been linked to adverse birth outcomes. Previous reports have shown that person-to-person transmission can occur by means of sexual contact. We conducted a prospective study involving men with symptomatic ZIKV infection to determine the frequency and duration of ZIKV shedding in semen and urine and to identify risk factors for prolonged shedding in these fluids. Specimens were obtained twice per month for 6 months after illness onset and were tested by real-time reverse-transcriptase-polymerase-chain-reaction (RT-PCR) assay for ZIKV RNA and by Vero cell culture and plaque assay for infectious ZIKV. A total of 1327 semen samples from 184 men and 1038 urine samples from 183 men were obtained 14 to 304 days after illness onset. ZIKV RNA was detected in the urine of 7 men (4%) and in the semen of 60 (33%), including in semen samples from 22 of 36 men (61%) who were tested within 30 days after illness onset. ZIKV RNA shedding in semen decreased substantially during the 3 months after illness onset but continued for 281 days in 1 man (1%). Factors that were independently associated with prolonged RNA shedding included older age, less frequent ejaculation, and the presence of certain symptoms at the time of initial illness. Infectious ZIKV was isolated from 3 of 78 semen samples with detectable ZIKV RNA, all obtained within 30 days after illness onset and all with at least 7.0 log 10 ZIKV RNA copies per milliliter of semen. ZIKV RNA was commonly present in the semen of men with symptomatic ZIKV infection and persisted in some men for more than 6 months. In contrast, shedding of infectious ZIKV appeared to be much less common and was limited to the first few weeks after illness onset. (Funded by the Centers for Disease Control and Prevention.).

  4. Intestinal Adenovirus Shedding Before Allogeneic Stem Cell Transplantation Is a Risk Factor for Invasive Infection Post-transplant

    Directory of Open Access Journals (Sweden)

    Karin Kosulin

    2018-02-01

    Full Text Available Human adenoviruses (HAdV are a major cause of morbidity and mortality in pediatric human stem cell transplant (HSCT recipients. Our previous studies identified the gastrointestinal tract as a site of HAdV persistence, but the role of intestinal virus shedding pre-transplant for the risk of ensuing invasive infection has not been entirely elucidated. Molecular HAdV monitoring of serial stool samples using RQ-PCR was performed in 304 children undergoing allogeneic HSCT. Analysis of stool and peripheral blood specimens was performed pre-transplant and at short intervals until day 100 post-HSCT. The virus was detected in the stool of 129 patients (42%, and 42 tested positive already before HSCT. The patients displaying HAdV shedding pre-transplant showed a significantly earlier increase of intestinal HAdV levels above the critical threshold associated with high risk of invasive infection (p < 0.01. In this subset of patients, the occurrence of invasive infection characterized by viremia was significantly higher than in patients without HAdV shedding before HSCT (33% vs 7%; p < 0.0001. The data demonstrate that intestinal HAdV shedding before HSCT confers a greatly increased risk for invasive infection and disseminated disease post-transplant, and highlights the need for timely HAdV monitoring and pre-emptive therapeutic considerations in HSCT recipients.

  5. Analysis of regional cerebral blood flow and distribution volume in Machado-Joseph disease by iodine-{sup 123}I IMP single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Tsunemi; Nakajima, Takashi; Fukuhara, Nobuyoshi [National Saigata Hospital, Ohagata, Niigata (Japan)

    2001-09-01

    Machado-Joseph disease (MJD) is an autosomal dominant spinocerebellar ataxia. Its clinical features vary greatly in different generations of the same family. Regional cerebral blood flow (rCBF) and distribution volume (V{sub d}) in the pons, cerebellum, and cerebral cortex were measured in 12 patients with MJD by autoradiography (ARG) and the table look-up (TLU) method of iodine-123 IMP ({sup 123}I-IMP) single photon emission computed tomography (SPECT). Representative cases were as follows: A 46-year-old woman first experienced gait ataxia at age 38. Computed tomography (CT) and magnetic resonance imaging (MRI) showed no atrophy in the pons or cerebellum, but rCBF measured by the {sup 123}I-IMP SPECT ARG method detected hypoperfusion in the pons, and cerebellar vermis and hemisphere. A 76-year-old woman first experienced gait ataxia at age 69. CT and MRI findings showed severe atrophy in the pons, and cerebellar vermis and hemisphere. Moreover, rCBF was decreased in the pons, whereas it was not decreased in the cerebellar vermis and hemisphere. In the pons of patients with MJD, rCBF was markedly decreased regardless of disease severity. Because this SPECT finding for the pons looked like a 'dot', we have called it the 'pontine dot sign'. In the MJD group, rCBF was significantly decreased in the pons (Student's t test, p<0.01) and cerebellar vermis (p<0.05). The V{sub d} was also significantly decreased in the pons (p<0.005) in comparison with that for normal subjects. Pearson's correlation analysis yielded a significant relationship between the rCBF in the pons and age at onset (r=0.578, p<0.05). There was a strong correlation between the V{sub d} for the pons and age at onset (r=0.59, p<0.05). Person's correlation analysis also showed a significant relationship between the V{sub d} in the cerebellar hemispheres and International Cooperative Ataxia Rating Scale (r=0.644, p<0.05). The pontine rCBFs in patients with early onset MJD

  6. Hepatocyte growth factor inhibitor-2 prevents shedding of matritpase

    DEFF Research Database (Denmark)

    Larsen, Brian R; Steffensen, Simon D; Nielsen, Nis V L

    2013-01-01

    Hepatocyte growth factor activator inhibitor-2 (HAI-2) is an inhibitor of many proteases in vitro, including the membrane-bound serine protease, matriptase. Studies of knock-out mice have shown that HAI-2 is essential for placental development only in mice expressing matriptase, suggesting that HAI......-2 is important for regulation of matriptase. Previous studies have shown that recombinant expression of matriptase was unsuccessful unless co-expressed with another HAI, HAI-1. In the present study we show that when human matriptase is recombinantly expressed alone in the canine cell line MDCK......, then human matriptase mRNA can be detected and the human matriptase ectodomain is shed to the media, suggesting that matriptase expressed alone is rapidly transported through the secretory pathway and shed. Whereas matriptase expressed together with HAI-1 or HAI-2 accumulates on the plasma membrane where...

  7. Syndecan-4 shedding impairs macrovascular angiogenesis in diabetes mellitus

    Energy Technology Data Exchange (ETDEWEB)

    Li, Ran; Xie, Jun; Wu, Han; Li, Guannan; Chen, Jianzhou; Chen, Qinhua; Wang, Lian; Xu, Biao, E-mail: xubiao@medmail.com.cn

    2016-05-20

    Purpose: Syndecan-4 (synd4) is a ubiquitous heparan sulfate proteoglycan cell surface receptor that modulates cell proliferation, migration, mechanotransduction, and endocytosis. The extracellular domain of synd4 sheds heavily in acute inflammation, but the shedding of synd4 in chronic inflammation, such as diabetes mellitus (DM), is still undefined. We investigated the alterations of synd4 endothelial expression in DM and the influence of impaired synd4 signaling on angiogenesis in human umbilical vein endothelial cells (HUVECs), diabetic rats, synd4 null mice, and db/db mice. Material and methods: HUVECs were incubated with advanced glycation end products (AGEs). Western blot analysis was used to determine synd4 protein expression and ELISA was used to detect soluble synd4 fragments. The concentration of synd4 in the aortic endothelia of diabetic rats was detected by immunohistochemical staining. Aortic ring assays were performed to study the process of angiogenesis in the diabetic rats and in synd4 null and db/db mice. Recombinant adenoviruses containing the synd4 gene or null were constructed to enhance synd4 aortic expression in db/db mice. Results: Western blot analysis showed decreased expression of the synd4 extracellular domain in HUVECs, and ELISA detected increased soluble fragments of synd4 in the media. Synd4 endothelial expression in the aortas of diabetic rats was decreased. Aortic ring assay indicated impaired angiogenesis in synd4 null and db/db mice, which was partially reversed by synd4 overexpression in db/db mice. Conclusion: Synd4 shedding from vascular endothelial cells played an important role in the diabetes-related impairment of angiogenesis. -- Highlights: •Synd4 shedding from endothelial cells is accelerated under the stimulation of AGEs. •Extracellular domain of synd4 is diminished in the endothelium of DM rats. •Aortic rings of synd4 null mice showed impaired angiogenesis. •Overexpression of synd4 partly rescues macrovascular

  8. Vortex Shedding from Tapered Cylinders at high Reynolds Numbers

    DEFF Research Database (Denmark)

    Johansson, Jens; Andersen, Michael Styrk; Christensen, Silas Sverre

    2015-01-01

    percent for strakes of circular cross section. The present paper argues that this height can be reduced for structures where the critical wind velocity for vortex shedding is in the Supercritical Reynolds number regime. The present investigations are aimed for suppressing VIV on offshore wind turbine......^5 (Supercritical). Results indicate that circular strakes with a diameter corresponding to 3 percent of the structures mean diameter can be used to efficiently reduce VIV in the Supercritical Reynolds number regime....

  9. Birds shed RNA-viruses according to the pareto principle.

    Science.gov (United States)

    Jankowski, Mark D; Williams, Christopher J; Fair, Jeanne M; Owen, Jennifer C

    2013-01-01

    A major challenge in disease ecology is to understand the role of individual variation of infection load on disease transmission dynamics and how this influences the evolution of resistance or tolerance mechanisms. Such information will improve our capacity to understand, predict, and mitigate pathogen-associated disease in all organisms. In many host-pathogen systems, particularly macroparasites and sexually transmitted diseases, it has been found that approximately 20% of the population is responsible for approximately 80% of the transmission events. Although host contact rates can account for some of this pattern, pathogen transmission dynamics also depend upon host infectiousness, an area that has received relatively little attention. Therefore, we conducted a meta-analysis of pathogen shedding rates of 24 host (avian) - pathogen (RNA-virus) studies, including 17 bird species and five important zoonotic viruses. We determined that viral count data followed the Weibull distribution, the mean Gini coefficient (an index of inequality) was 0.687 (0.036 SEM), and that 22.0% (0.90 SEM) of the birds shed 80% of the virus across all studies, suggesting an adherence of viral shedding counts to the Pareto Principle. The relative position of a bird in a distribution of viral counts was affected by factors extrinsic to the host, such as exposure to corticosterone and to a lesser extent reduced food availability, but not to intrinsic host factors including age, sex, and migratory status. These data provide a quantitative view of heterogeneous virus shedding in birds that may be used to better parameterize epidemiological models and understand transmission dynamics.

  10. Birds shed RNA-viruses according to the pareto principle.

    Directory of Open Access Journals (Sweden)

    Mark D Jankowski

    Full Text Available A major challenge in disease ecology is to understand the role of individual variation of infection load on disease transmission dynamics and how this influences the evolution of resistance or tolerance mechanisms. Such information will improve our capacity to understand, predict, and mitigate pathogen-associated disease in all organisms. In many host-pathogen systems, particularly macroparasites and sexually transmitted diseases, it has been found that approximately 20% of the population is responsible for approximately 80% of the transmission events. Although host contact rates can account for some of this pattern, pathogen transmission dynamics also depend upon host infectiousness, an area that has received relatively little attention. Therefore, we conducted a meta-analysis of pathogen shedding rates of 24 host (avian - pathogen (RNA-virus studies, including 17 bird species and five important zoonotic viruses. We determined that viral count data followed the Weibull distribution, the mean Gini coefficient (an index of inequality was 0.687 (0.036 SEM, and that 22.0% (0.90 SEM of the birds shed 80% of the virus across all studies, suggesting an adherence of viral shedding counts to the Pareto Principle. The relative position of a bird in a distribution of viral counts was affected by factors extrinsic to the host, such as exposure to corticosterone and to a lesser extent reduced food availability, but not to intrinsic host factors including age, sex, and migratory status. These data provide a quantitative view of heterogeneous virus shedding in birds that may be used to better parameterize epidemiological models and understand transmission dynamics.

  11. Laminar vortex shedding behind a cooled circular cylinder

    Czech Academy of Sciences Publication Activity Database

    Trávníček, Zdeněk; Wang, A. B.; Tu, W.Y.

    2014-01-01

    Roč. 55, č. 2 (2014), s. 1-12 ISSN 0723-4864 R&D Projects: GA ČR GA14-08888S Institutional support: RVO:61388998 Keywords : vortex shedding * cooled circular cylinder * thermal effect Subject RIV: JU - Aeronautics, Aerodynamics, Aircrafts Impact factor: 1.670, year: 2014 http://link.springer.com/journal/348/55/2/page/1

  12. Reliability Constrained Priority Load Shedding for Aerospace Power System Automation

    Science.gov (United States)

    Momoh, James A.; Zhu, Jizhong; Kaddah, Sahar S.; Dolce, James L. (Technical Monitor)

    2000-01-01

    The need for improving load shedding on board the space station is one of the goals of aerospace power system automation. To accelerate the optimum load-shedding functions, several constraints must be involved. These constraints include congestion margin determined by weighted probability contingency, component/system reliability index, generation rescheduling. The impact of different faults and indices for computing reliability were defined before optimization. The optimum load schedule is done based on priority, value and location of loads. An optimization strategy capable of handling discrete decision making, such as Everett optimization, is proposed. We extended Everett method to handle expected congestion margin and reliability index as constraints. To make it effective for real time load dispatch process, a rule-based scheme is presented in the optimization method. It assists in selecting which feeder load to be shed, the location of the load, the value, priority of the load and cost benefit analysis of the load profile is included in the scheme. The scheme is tested using a benchmark NASA system consisting of generators, loads and network.

  13. Genital HSV Shedding among Kenyan Women Initiating Antiretroviral Therapy.

    Directory of Open Access Journals (Sweden)

    Griffins O Manguro

    Full Text Available Genital ulcer disease (GUD prevalence increases in the first month of antiretroviral treatment (ART, followed by a return to baseline prevalence by month 3. Since most GUD is caused by herpes simplex virus type 2 (HSV-2, we hypothesized that genital HSV detection would follow a similar pattern after treatment initiation.We conducted a prospective cohort study of 122 HSV-2 and HIV-1 co-infected women with advanced HIV disease who initiated ART and were followed closely with collection of genital swab specimens for the first three months of treatment.At baseline, the HSV detection rate was 32%, without significant increase in genital HSV detection noted during the first month or the third month of ART. HIV-1 shedding declined during this period; no association was also noted between HSV and HIV-1 shedding during this period.Because other studies have reported increased HSV detection in women initiating ART and we have previously reported an increase in GUD during early ART, it may be prudent to counsel HIV-1 infected women initiating ART that HSV shedding in the genital tract may continue after ART initiation.

  14. Postoperative volume balance

    DEFF Research Database (Denmark)

    Frost, H; Mortensen, C.R.; Secher, Niels H.

    2017-01-01

    In healthy humans, stroke volume (SV) and cardiac output (CO) do not increase with expansion of the central blood volume by head-down tilt or administration of fluid. Here, we exposed 85 patients to Trendelenburg's position about one hour after surgery while cardiovascular variables were determin...

  15. Polynitroxylated Pegylated Hemoglobin-A Novel, Small Volume Therapeutic for Traumatic Brain Injury Resuscitation: Comparison to Whole Blood and Dose Response Evaluation.

    Science.gov (United States)

    Brockman, Erik C; Jackson, Travis C; Dixon, C Edward; Bayɪr, Hülya; Clark, Robert S B; Vagni, Vincent; Feldman, Keri; Byrd, Catherine; Ma, Li; Hsia, Carleton; Kochanek, Patrick M

    2017-04-01

    Resuscitation with polynitroxylated pegylated hemoglobin (PNPH), a pegylated bovine hemoglobin decorated with nitroxides, eliminated the need for fluid administration, reduced intracranial pressure (ICP) and brain edema, and produced neuroprotection in vitro and in vivo versus Lactated Ringer's solution (LR) in experimental traumatic brain injury (TBI) plus hemorrhagic shock (HS). We hypothesized that resuscitation with PNPH would improve acute physiology versus whole blood after TBI+HS and would be safe and effective across a wide dosage range. Anesthetized mice underwent controlled cortical impact and severe HS to mean arterial pressure (MAP) of 25-27 mm Hg for 35 min, then were resuscitated with PNPH, autologous whole blood, or LR. Markers of acute physiology, including mean arterial blood pressure (MAP), heart rate (HR), blood gases/chemistries, and brain oxygenation (PbtO 2 ), were monitored for 90 min on room air followed by 15 min on 100% oxygen. In a second experiment, the protocol was repeated, except mice were resuscitated with PNPH with doses between 2 and 100 mL/kg. ICP and 24 h %-brain water were evaluated. PNPH-resuscitated mice had higher MAP and lower HR post-resuscitation versus blood or LR (p < 0.01). PNPH-resuscitated mice, versus those resuscitated with blood or LR, also had higher pH and lower serum potassium (p < 0.05). Blood-resuscitated mice, however, had higher PbtO 2 versus those resuscitated with LR and PNPH, although PNPH had higher PbtO 2 versus LR (p < 0.05). PNPH was well tolerated across the dosing range and dramatically reduced fluid requirements in all doses-even 2 or 5 mL/kg (p < 0.001). ICP was significantly lower in PNPH-treated mice for most doses tested versus in LR-treated mice, although %-brain water did not differ between groups. Resuscitation with PNPH, versus resuscitation with LR or blood, improved MAP, HR, and ICP, reduced acidosis and hyperkalemia, and was well tolerated and effective

  16. Polynitroxylated Pegylated Hemoglobin—A Novel, Small Volume Therapeutic for Traumatic Brain Injury Resuscitation: Comparison to Whole Blood and Dose Response Evaluation

    Science.gov (United States)

    Brockman, Erik C.; Jackson, Travis C.; Dixon, C. Edward; Bayɪr, Hülya; Clark, Robert S. B.; Vagni, Vincent; Feldman, Keri; Byrd, Catherine; Ma, Li; Hsia, Carleton

    2017-01-01

    Abstract Resuscitation with polynitroxylated pegylated hemoglobin (PNPH), a pegylated bovine hemoglobin decorated with nitroxides, eliminated the need for fluid administration, reduced intracranial pressure (ICP) and brain edema, and produced neuroprotection in vitro and in vivo versus Lactated Ringer's solution (LR) in experimental traumatic brain injury (TBI) plus hemorrhagic shock (HS). We hypothesized that resuscitation with PNPH would improve acute physiology versus whole blood after TBI+HS and would be safe and effective across a wide dosage range. Anesthetized mice underwent controlled cortical impact and severe HS to mean arterial pressure (MAP) of 25–27 mm Hg for 35 min, then were resuscitated with PNPH, autologous whole blood, or LR. Markers of acute physiology, including mean arterial blood pressure (MAP), heart rate (HR), blood gases/chemistries, and brain oxygenation (PbtO2), were monitored for 90 min on room air followed by 15 min on 100% oxygen. In a second experiment, the protocol was repeated, except mice were resuscitated with PNPH with doses between 2 and 100 mL/kg. ICP and 24 h %-brain water were evaluated. PNPH-resuscitated mice had higher MAP and lower HR post-resuscitation versus blood or LR (p < 0.01). PNPH-resuscitated mice, versus those resuscitated with blood or LR, also had higher pH and lower serum potassium (p < 0.05). Blood-resuscitated mice, however, had higher PbtO2 versus those resuscitated with LR and PNPH, although PNPH had higher PbtO2 versus LR (p < 0.05). PNPH was well tolerated across the dosing range and dramatically reduced fluid requirements in all doses—even 2 or 5 mL/kg (p < 0.001). ICP was significantly lower in PNPH-treated mice for most doses tested versus in LR-treated mice, although %-brain water did not differ between groups. Resuscitation with PNPH, versus resuscitation with LR or blood, improved MAP, HR, and ICP, reduced acidosis and hyperkalemia, and was well tolerated and

  17. Timing of blood transfusion and not ABO blood type is associated with survival in patients treated with radical cystectomy for nonmetastatic bladder cancer: Results from a single high-volume institution.

    Science.gov (United States)

    Moschini, Marco; Bianchi, Marco; Rossi, Martina Sofia; Dell׳Oglio, Paolo; Gandaglia, Giorgio; Fossati, Nicola; Mattei, Agostino; Damiano, Rocco; Shariat, Shahrokh F; Salonia, Andrea; Montorsi, Francesco; Briganti, Alberto; Colombo, Renzo; Gallina, Andrea

    2016-06-01

    Perioperative transfusions have been recently associated to poor outcomes as an indirect consequence of immune-hematological changes related to transfusion itself and blood type. We tested the role of blood transfusion on cancer-specific mortality (CSM) and overall mortality (OM), considering the effect of ABO system, Rh factor, and timing of transfusions. The study focused on 728 patients with bladder cancer treated with radical cystectomy at a single tertiary care referral center between January 1995 and August 2013 with complete ABO blood type information. Kaplan-Meier analysis was used to assess the effect of transfusions, stratified according to ABO type and Rh factor, on CSM and OM. The same endpoints were tested in Cox regression models, after adjusting for all available confounders. A total of 341 (46.8%), 277 (38.0%), 83 (11.4%), and 27 (3.7%) patients had blood type O, A, B and AB, respectively. Overall, 630 (86.5%) and 98 (13.5%) patients were Rh-and Rh+, respectively. At a median follow-up time of 65 months, 225 (30.9%) and 282 (38.7%) patients recorded CSM and OM, respectively. At univariable analyses, ABO blood type and Rh status were not associated to either CSM or OM (all P>0.2). Similar results were observed when ABO blood type and Rh factor were tested in multivariable models (all P>0.3). Conversely, Charlson score, preoperative hemoglobin, number of nodes removed, pathological T stage, and number of positive nodes were associated to both CSM and OM (all Pblood units in the postoperative period (P>0.05) was associated with an increase of CSM and OM. Although ABO type or Rh factor or both were associated with several adverse outcomes in many cancers, we were not able to confirm this association in bladder cancer. Based on our results, the effect of transfusion on survival is independent by ABO type but is associated to the timing of blood supply administration. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Age-Related Differences in Memory and Executive Functions in Healthy "APOE"[epsilon]4 Carriers: The Contribution of Individual Differences in Prefrontal Volumes and Systolic Blood Pressure

    Science.gov (United States)

    Bender, Andrew R.; Raz, Naftali

    2012-01-01

    Advanced age and vascular risk are associated with declines in the volumes of multiple brain regions, especially the prefrontal cortex, and the hippocampus. Older adults, even unencumbered by declining health, perform less well than their younger counterparts in multiple cognitive domains, such as episodic memory, executive functions, and speed of…

  19. The peculiarities of regional volume cerebral blood flow in patients with hypertensive encephalopathy by the findings of single photon emission computed tomography

    International Nuclear Information System (INIS)

    Makejev, S.S.; Novyikova, T.G.; Kustkova, A.S.

    2012-01-01

    The investigation of the state of the brain perfusion in patients with stage II hypertensive encephalopathy (HE) at development of hypertension crisis vs. crisis-free course of HE showed that in 79,5% of the patients with stage II HE, single photon emission computed tomography demonstrated local changes of the blood flow

  20. Blood pressure

    Science.gov (United States)

    Normal blood pressure is important for proper blood flow to the body's organs and tissues. The force of the blood on the walls of the arteries is called blood pressure. Blood pressure is measured both as the heart ...

  1. Blood Types

    Science.gov (United States)

    ... blood, safe blood transfusions depend on careful blood typing and cross-matching. There are four major blood ... cause exceptions to the above patterns. ABO blood typing is not sufficient to prove or disprove paternity ...

  2. [Alternatives to allogenous blood transfusion].

    Science.gov (United States)

    Cernea, Daniela; Vlădoianu, Alice; Stoica, Maria; Novac, M; Berteanu, Cristina

    2009-01-01

    Blood transfusion is usually meant to lower morbidity and mortality rates. Allogenous blood transfusion implies certain risks that can be avoided by autologous blood transfusions techniques including: preoperatory autologous blood donation, acute normovolemic hemodilution, intraoperatory and postoperatory blood salvage. Preoperatory blood donation and acute normovolemic hemodilution are used for planned interventions with an estimated blood loss higher than 20% of blood volume. These methods imply Erythropoietin and iron treatment. Intraoperatory and postoperatory blood salvage is performed by personnel trained in blood donation, handling and storage. Autologous blood transfusions are used for certain surgical procedures that commonly require transfusions: orthopedic surgery, radical prostatectomy, cardiovascular surgery, organ transplantation. An alternative to allogenous blood transfusion is the use of artificial oxygen transporters: human or animal hemoglobin solutions or pefluorocarbonate solutions. These solutions do not require cross reactions, do not carry diseases and are generally well tolerated and easily stored in the operating room, ambulance and other transport means. They have however a slight degree of toxicity.

  3. Clinical application of a right ventricular pressure-volume loop determined by gated blood-pool imaging and simultaneously measured right ventricular pressure

    International Nuclear Information System (INIS)

    Yasue, Takao; Watanabe, Sachiro; Sugishita, Nobuyoshi; Tanaka, Tsutomu; Yokoyama, Hideo

    1983-01-01

    The data obtained by ECG-gated radionuclide angiography were collected simultaneously with right ventricular pressure and thermal cardiac output (CO) obtained by a Swan-Ganz catheter in Scintipac 1200 (Shimazu Co) in order to create a right ventricular pressure-volume (RV P-V) loop. Subjects consisted of 15 patients with old myocardial infarction (MI group), seven with angina pectoris (AP group), six with congestive cardiomyopathy (CCM group) and five with neurocirculatory asthenia (NCA group). Right ventricular end-diastolic volume (RVEDV) was calculated as RVEDV = CO/(EF x HR) (CO = cardiac output; HR = heart rate). Systolic work (W sub(S)), diastolic work (W sub(D)) and net work (W sub(N)) were calculated from a RV P-V loop by Simpson's method. The measurements were performed before and 5 min after sublingual administration of nitroglycerin (NG) (0.3 mg). The results were as follows: 1. RV P-V loops shifted towards the left lower part of the P-V plane after sublingual administration of nitroglycerin, indicating the reduction of pressure and volume of the right ventricle. 2. Right ventricular ejection fraction (RVEF) in the MI, AP and CCM groups showed smaller values than that of the NCA group. 3. Right ventricular end-diastolic volume index (RVEDVI) showed a converse relation with RVEF. 4. Cardiac index in all groups decreased after NG and a statistical significance was seen in the MI, AP and NCA groups (p<0.05). 5. RV W sub(S), RV W sub(D) and RV W sub(N) showed no difference among each groups in the control state, and significantly decreased after NG. We conclude that the present method using RV P-V loop might be useful as a noninvasive bedside monitoring and permits the evaluation of RV function in a clinical setting

  4. Men's Sheds function and philosophy: towards a framework for future research and men's health promotion.

    Science.gov (United States)

    Wilson, Nathan J; Cordier, Reinie; Doma, Kenji; Misan, Gary; Vaz, Sharmila

    2015-08-01

    The Men's Shed movement supports a range of men's health promotion initiatives. This paper examines whether a Men's Shed typology could inform future research and enable more efficient and targeted health promotion activities through Men's Sheds. The International Men's Shed Survey consisted of a cross-sectional exploration of sheds, their members, and health and social activities. Survey data about shed 'function' and 'philosophy' were analysed using descriptive and inferential statistics. A framework of Men's Sheds based on function and philosophy demonstrated that most sheds serve a primary utility function, a secondary social function, but most importantly a primary social opportunity philosophy. Sheds with a primary health philosophy participated in fewer health promotion activities when compared with sheds without a primary health philosophy. In addition to the uniform health promotion resources distributed by the Men's Shed associations, specific health promotion activities, such as prostate education, are being initiated from an individual shed level. This framework can potentially be used to enable future research and health promotion activities to be more efficiently and effectively targeted. SO WHAT? Men experience poorer health and well being outcomes than women. This framework offers a novel approach to providing targeted health promotion activities to men in an environment where it is okay to talk about men's health.

  5. Longitudinal prevalence and faecal shedding of Chlamydia pecorum in sheep.

    Science.gov (United States)

    Yang, Rongchang; Jacobson, Caroline; Gardner, Graham; Carmichael, Ian; Campbell, Angus J D; Ryan, Una

    2014-09-01

    The prevalence and faecal shedding of Chlamydia spp. in sheep in Australia has not been well described. Two species-specific quantitative PCRs (qPCRs) targeting the chlamydial outer membrane protein cell surface antigen gene (ompA) were validated and used to determine the prevalence and faecal shedding of C. abortus and C. pecorum from faecal samples of lambs at three sampling times (weaning, post-weaning and pre-slaughter) from eight farms in South Australia, New South Wales, Victoria and Western Australia. A total of 3412 faecal samples were collected and screened from approximately 1189 lambs across the four states. C. abortus was not detected in any of the samples screened. The overall prevalence of C. pecorum was 1027/3412 (30.1%) and median bacterial concentrations at weaning, post-weaning and pre-slaughter were 1.8 × 10(7), 1.2 × 10(7) and 9.6 × 10(5)/g faeces, respectively. A subset of C. pecorum positive samples from each farm, (n = 48) was sequenced to confirm their identity. The present study demonstrates that C. pecorum is prevalent in Australian sheep, highlighting a need for further research on the impact of this bacterium on production. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Measurement on the cavitating vortex shedding behind rectangular obstacles

    International Nuclear Information System (INIS)

    Hegedus, F; Hos, C; Pandula, Z; Kullmann, L

    2010-01-01

    Measurement results on the cavitating vortex shedding behind sharp-edged rectangular bodies are presented, intended to provide benchmark cases for the validation of unsteady cavitation models of CFD codes. Rectangular bodies of increasing aspect ratio (1, 2, 3 and 4) were used with a constant 25mm height (12.5% blockage ratio). The water velocity in the 0.2x0.05m test section of the channel was varied between 1 and 12 m/s resulting in a Reynolds number in the range of (0.4-3.5)x105. Pressure signals were measured at several locations, notably in the wake. Dominant frequencies and Strouhal numbers are reported from cavitation-free flow (classic von Karman vortex shedding) up to supercavitation as a function of the free-stream Reynolds number. The results are in good agreement with the literature in case of the square cylinder. We experienced a slight increase of the dominant Strouhal number with increasing aspect ratio. This result is somewhat inconsistent with the literature, in which a fall of the Strouhal number can be observed at side ratio 2. This may be the consequence of the different ranges of Reynolds numbers. It was also found that between the inception of cavitation and the formation of supercavitation the Strouhal number is not affected by cavitation.

  7. Measurement on the cavitating vortex shedding behind rectangular obstacles

    Energy Technology Data Exchange (ETDEWEB)

    Hegedus, F; Hos, C; Pandula, Z; Kullmann, L, E-mail: hegedusf@hds.bme.h [Department of Hydrodynamic Systems, Budapest University of Technology and Economics Muegyetem rkp. 1, Budapest 1111 (Hungary)

    2010-08-15

    Measurement results on the cavitating vortex shedding behind sharp-edged rectangular bodies are presented, intended to provide benchmark cases for the validation of unsteady cavitation models of CFD codes. Rectangular bodies of increasing aspect ratio (1, 2, 3 and 4) were used with a constant 25mm height (12.5% blockage ratio). The water velocity in the 0.2x0.05m test section of the channel was varied between 1 and 12 m/s resulting in a Reynolds number in the range of (0.4-3.5)x105. Pressure signals were measured at several locations, notably in the wake. Dominant frequencies and Strouhal numbers are reported from cavitation-free flow (classic von Karman vortex shedding) up to supercavitation as a function of the free-stream Reynolds number. The results are in good agreement with the literature in case of the square cylinder. We experienced a slight increase of the dominant Strouhal number with increasing aspect ratio. This result is somewhat inconsistent with the literature, in which a fall of the Strouhal number can be observed at side ratio 2. This may be the consequence of the different ranges of Reynolds numbers. It was also found that between the inception of cavitation and the formation of supercavitation the Strouhal number is not affected by cavitation.

  8. Conventional blood conservation techniques in 500 consecutive coronary artery bypass operations.

    Science.gov (United States)

    Ovrum, E; Holen, E A; Abdelnoor, M; Oystese, R

    1991-09-01

    With use of a nonpharmacological, simple, and inexpensive program for blood conservation, 500 consecutive patients underwent elective coronary artery bypass grafting without need of homologous red cell transfusions in 493 (98.6%). At least one internal mammary artery was grafted in all but 1 patient, with supplemental saphenous vein grafts. Intraoperatively, autologous heparinized blood was removed before bypass and retransfused at the conclusion of extracorporeal circulation. The volume remaining in the oxygenator and tubing set was returned without cell processing or hemofiltration. Using the hard-shell cardiotomy reservoir from the heart-lung machine, autotransfusion of the shed mediastinal blood was continued hourly up to 18 hours after operation. The mean postoperative mediastinal blood loss was 643 +/- 354 mL, whereas 624 +/- 296 mL was autotransfused. Thirteen patients (2.6%) needed reexploration for bleeding, of whom 7 (7/500, 1.4%) received homologous blood. No other patients required red cell transfusions. In addition, 9 patients were given a mean of 2.6 units of fresh frozen plasma because of suspected coagulopathy. No platelets were transfused, and no cryoprecipitate therapy was undertaken. Thus, in total, 484 patients (96.8%) were not exposed to any homologous blood products during the hospital stay. At discharge, the mean hemoglobin concentration was 121 +/- 14 g/L (12.1 +/- 1.4 g/dL) and the hematocrit, 0.36 +/- 0.04. Postoperative complications were few. There was one in-hospital death (0.2%).

  9. Volume Replacement Therapy during Hip Arthroplasty using Hydroxyethyl Starch (130/0.4 Compared to Lactated Ringer Decreases Allogeneic Blood Transfusion and Postoperative Infection

    Directory of Open Access Journals (Sweden)

    Adilson Hamaji

    2013-01-01

    Full Text Available Background and objectives: Hydroxyethyl starch (HES 130/0.4 is considered an effective plasma expander when compared to crystalloids. There is controversy around its superiority regarding hemodynamic optimization and about possible detrimental effects on coagulation. The aim of this study was to compare the effects of HES 130/0.4 to lactated Ringer solution during hip arthroplasty in adult patients under spinal anesthesia regarding intraoperative bleeding, hemodynamic parameters, coagulation profile, transfusion requirements and clinical outcomes. Methods: In this randomized, controlled trial, 48 patients scheduled for hip arthroplasty with spinal anesthesia were randomized into two groups: 24 patients were allocated to receive a preload of 15 mL.kg-1 of HES 130/0.4 and 24 patients received a preload of 30 mL.kg-1 lactated Ringer solution before surgery. Hemodynamic measurements, hemoglobin concentrations, biochemical parameters and coagulation tests were evaluated in three periods during surgical procedure. Patients received medical follow-up during their hospital stay and up to postoperative 30 days. Primary outcome was the requirement of red blood cell transfusion between groups during hospital stay. Secondary outcome were hemodynamic parameters, length of hospital stay, mortality and occurrence of clinical postoperative complications. Results: Red blood cell transfusion was required in 17% of patients in the HES group and in 46% in the Ringer group (p = .029. Postoperative infections were more frequently observed in the Ringer group (17% compared to the HES group (0, p = .037. There were no significant differences between groups in mortality, hospital length of stay and clinical complications other than infection. Conclusions: During hip arthroplasty, patients treated with hypervolemic hemodilution with hydroxyethyl starch 130/0.4 required less transfusion and presented lower infection rate compared to patients who received lactated

  10. Two-Stage Load Shedding for Secondary Control in Hierarchical Operation of Islanded Microgrids

    DEFF Research Database (Denmark)

    Zhou, Quan; Li, Zhiyi; Wu, Qiuwei

    2018-01-01

    A two-stage load shedding scheme is presented to cope with the severe power deficit caused by microgrid islanding. Coordinated with the fast response of inverter-based distributed energy resources (DERs), load shedding at each stage and the resulting power flow redistribution are estimated....... The first stage of load shedding will cease rapid frequency decline in which the measured frequency deviation is employed to guide the load shedding level and process. Once a new steady-state is reached, the second stage is activated, which performs load shedding according to the priorities of loads...

  11. The Role of Collaborative Learning on Training and Development Practices within the Australian Men's Shed Movement: A Study of Five Men's Sheds

    Science.gov (United States)

    Cavanagh, Jillian; Southcombe, Amie; Bartram, Tim

    2014-01-01

    This study examines the role and impact of collaborative learning on training and development practices in Australian Men's Sheds. We use a case study approach, underpinned by Peters and Armstrong's theoretical framework of collaborative learning in adult education, to investigate five Men's Sheds. Semi-structured interviews were carried out with…

  12. Determination of proguanil and metabolites in small sample volumes of whole blood stored on filter paper by high-performance liquid chromatography.

    Science.gov (United States)

    Kolawole, J A; Taylor, R B; Moody, R R

    1995-12-01

    A method is reported for the determination of proguanil and its two metabolites cycloguanil and 4-chlorophenylbiguanide in whole blood and plasma samples obtained by thumbprick and stored dry on filter paper. The sample preparation involves liquid extraction from the filter paper and subsequent solid-phase extraction using C8 Bond-Elut cartridges. Separation and quantification is by a previously reported ion-pairing high-performance liquid chromatographic system with ODS Hypersil as stationary phase and an 50:50 acetonitrile-pH 2 phosphate buffer mobile phase containing 200 mM sodium dodecylsulphate as ion-pairing agent. The analytical characteristics of the method are reported. Representative concentrations are shown as a function of time from a human subject after ingestion of a single 200-mg dose of proguanil hydrochloride. Typical ranges of concentration detected by the proposed method in human subjects were proguanil 12-900 ng/ml, cycloguanil 16-44 ng/ml and 4-chlorophenylbiguanide 1.5-10 ng/ml in whole blood.

  13. Combined aprotinin and erythropoietin use for blood conservation: results with Jehovah's Witnesses.

    Science.gov (United States)

    Rosengart, T K; Helm, R E; Klemperer, J; Krieger, K H; Isom, O W

    1994-11-01

    Despite recent advances in blood conservation techniques, major risks persist for excessive bleeding and blood transfusion after open heart operations. We reviewed the records of 100 consecutive patients undergoing first-time coronary artery bypass grafting at our institution to define these risks and develop a multimodality blood conservation program based on the results. This program was subsequently applied on a prospective basis to a select group of patients who refuse blood transfusion on religious grounds (Jehovah's Witnesses [JW]) (n = 15). Encouraging initial results with coronary artery bypass grafting in this group (n = 8) led to the application of the program to more complex operations (n = 7), including repeat bypass grafting with use of the internal mammary artery, repeat mitral valve replacement, aortic and mitral valve replacement with coronary artery bypass grafting, mitral valve replacement with bypass grafting, chronic type 1 dissection repair, aortic valve replacement, and atrial septal defect repair in 1 patient each. The blood conservation program employed in these patients included the use of (1) aprotinin (full Hammersmith regimen), (2) high-dose erythropoietin, (3) "maximal"-volume intraoperative autologous blood donation, (4) low-prime cardiopulmonary bypass, (5) exclusive use of intraoperative cell salvage, and (6) continuous reinfusion of shed mediastinal blood. There were no deaths in the JW group. Thromboembolic complications consisted of a transient posterior circulation stroke in only 1 patient (dissection repair). No blood or blood products were transfused compared with the transfusion of 5.1 +/- 7.8 units (mean +/- standard deviation) in the 100 primary coronary bypass patients in whom the blood conservation program was not employed.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Shedding light on restoring respiratory function after spinal cord injury

    Directory of Open Access Journals (Sweden)

    Warren J Alilain

    2009-10-01

    Full Text Available Loss of respiratory function is one of the leading causes of death following spinal cord injury. Because of this, much work has been done in studying ways to restore respiratory function following SCI - including pharmacological and regeneration strategies. With the emergence of new and powerful tools from molecular neuroscience, new therapeutically relevant alternatives to these approaches have become available, including expression of light sensitive proteins called channelrhodopsins. In this article we briefly review the history of various attempts to restore breathing after C2 hemisection, and focus on our recent work using the activation of light sensitive channels to restore respiratory function after experimental spinal cord injury. We also discuss how such light induced activity can help shed light on the inner workings of the central nervous system respiratory circuitry that controls diaphragmatic function.

  15. Hjemløshed i Grønland

    DEFF Research Database (Denmark)

    Hansen, Knud Erik; Andersen, Hans Thor

    Rapporten giver en beskrivelse af karakteren af hjemløsheden i Grønland. Den beskriver forholdene for tre måder at være ude i hjemløshed på i Grønland, hvordan husstande når dertil og hvilke muligheder de har for at komme ud af hjemløsheden. I rapporten indgår beskrivelser af en række personers liv...... households get homeless and their options to get out of homelessness. The report contains descriptions of how a number of people live in homelessness. The three types are: Homeless with no fixed accommodation, resettled living in resettlement housing and homeless who are long-time living with family, friends...

  16. Epstein-Barr virus shedding by astronauts during space flight

    Science.gov (United States)

    Pierson, D. L.; Stowe, R. P.; Phillips, T. M.; Lugg, D. J.; Mehta, S. K.

    2005-01-01

    Patterns of Epstein-Barr virus (EBV) reactivation in 32 astronauts and 18 healthy age-matched control subjects were characterized by quantifying EBV shedding. Saliva samples were collected from astronauts before, during, and after 10 space shuttle missions of 5-14 days duration. At one time point or another, EBV was detected in saliva from each of the astronauts. Of 1398 saliva specimens from 32 astronauts, polymerase chain reaction analysis showed that 314 (23%) were positive for EBV DNA. Examination by flight phase showed that 29% of the saliva specimens collected from 28 astronauts before flight were positive for EBV DNA, as were 16% of those collected from 25 astronauts during flight and 16% of those collected after flight from 23 astronauts. The mean number of EBV copies from samples taken during the flights was 417 per mL, significantly greater (p<.05) than the number of viral copies from the preflight (40) and postflight (44) phases. In contrast, the control subjects shed EBV DNA with a frequency of 3.7% and mean number of EBV copies of 40 per mL of saliva. Ten days before flight and on landing day, titers of antibody to EBV viral capsid antigen were significantly (p<.05) greater than baseline levels. On landing day, urinary levels of cortisol and catecholamines were greater than their preflight values. In a limited study (n=5), plasma levels of substance P and other neuropeptides were also greater on landing day. Increases in the number of viral copies and in the amount of EBV-specific antibody were consistent with EBV reactivation before, during, and after space flight.

  17. Nocturnal drainage wind characteristics in two converging air sheds

    International Nuclear Information System (INIS)

    Gedayloo, T.; Clements, W.E.; Barr, S.; Archuleta, J.A.

    1980-01-01

    During the short experimental period in the Grants Basin of Northeastern New Mexico a survey was conducted on the complex meteorology of this area. Emphasis was placed on the nocturnal drainage flow because of the potential hazards to the populated areas of Milan and Grants from the effluents of the uranium mining and milling operation in this area. This investigation has shown that the nocturnal drainage flow patterns agree with the winds predicted on the basis of the complex terrain of the area. Because of the surface cooling at night (over 25 0 C during summer and about 20 0 C during winter), air from elevated surrounding areas flows to the low lying regions consequently setting up a nocturnal drainage flow. This regime exists over 60% of the time during summer months and over 65% of the time during winter months with a depth generally less than 200 m. In the San Mateo air shed the drainage flow is east northeast, and in the Ambrosia Lake air shed it is from northwest. The confluence of these two air flows contributes mainly to the drainage flow through the channel formed by La Ja Mesa and Mesa Montanosa. The analysis of data collected by the recording Flats Station confirms the prediction that although the area south of the channel region broadens considerably causing a reduction in flow speed, contributions from the southside of La Jara Mesa and Mesa Montanosa partly compensate for this reduction. The position of this recording station is 15 to 20 km from the populated towns of Milan and Grants. A drainage flow speed of approximately 2.2 m s -1 and the duration of over 11 hours as recorded by this station indicates that air from the San Mateo and Ambrosia Lake regions may be transported southwards to these population centers during a nocturnal period. In order to test this prediction, a series of multi-atmospheric tracer experiments were conducted in the Grants Basin

  18. [Effect of different volumes of fluid resuscitation on hemorrhagic shock with pulmonary edema at high altitude in the unacclimated rat].

    Science.gov (United States)

    Liu, Liang-ming; Hu, De-yao; Liu, Jian-cang; Li, Ping; Liu, Hou-dong; Xiao, Nan; Zhou, Xue-wu; Tian, Kun-lun; Huo, Xiao-ping; Shi, Quan-gui; He, Yan-mei; Yin, Zuo-ming

    2003-05-01

    To study the effects of different volumes of fluid resuscitation on hemorrhagic shock with pulmonary edema at high altitude in the unacclimated rat. One hundred and twenty-six SD rats transported to Lasa, Tibet, 3 760 meters above the sea level, were anesthetized one week later with sodium pentobarbital (30 mg/kg, intraperitoneal). Hemorrhagic shock with pulmonary edema model was induced by hemorrhage (50 mm Hg for 1 hour, 1 mmHg=0.133 kPa) plus intravenous injection of oleic acid (50 microl/kg). Experiments were then conducted in two parts. Sixty-three rats in part I were equally divided into nine groups (n=7): normal control, hemorrhagic shock control, hemorrhagic shock with pulmonary edema (HSPE) without fluid infusion, HSPE plus infusing lactated Ringer's solution (LR) with 0.5-, 1-, 1.5-, 2- or 3- fold volume shed blood, and 1 volume of LR plus mannitol (10 ml/kg). Hemodynamic parameters including mean arterial blood pressure (MAP), left intraventricular systolic pressure (LVSP) and the maximal change rate of intraventricular pressure rise or decline (+/- dp/dt max) were observed at 15, 30, 60 and 120 minutes after infusion, blood gases were measured at 30 and 120 minutes after infusion and the water content of lung and brain was determined at 120 minutes after infusion. In part II, additional 63 rats were used to observe the effect of different volumes of fluid resuscitation on survival time of HSPE rats. 0.5 volume of LR infusion significantly improved MAP, LVSP and +/- dp/dt max, prolonged the survival time of HSPE animals (all P<0.01), while it did not increase the water content of lung and brain and had no marked influence on blood gases. One volume of LR infusion slightly improved hemodynamic parameters, prolonged the survival time and increased the water content of lung. More than 1 volume of LR infusion including 1.5-, 2- and 3- fold volume LR deteriorated the hemodynamic parameters and decreased the survival time of shocked animal, meanwhile they

  19. Electroencephalography reveals lower regional blood perfusion and atrophy of the temporoparietal network associated with memory deficits and hippocampal volume reduction in mild cognitive impairment due to Alzheimer’s disease

    Directory of Open Access Journals (Sweden)

    Moretti DV

    2015-02-01

    Full Text Available Davide Vito MorettiNational Institute for the research and cure of Alzheimer’s disease, S. John of God, Fatebenefratelli, Brescia, Italy Background: An increased electroencephalographic (EEG upper/lower alpha power ratio has been associated with less regional blood perfusion, atrophy of the temporoparietal region of the brain, and reduction of hippocampal volume in subjects affected by mild cognitive impairment due to Alzheimer’s disease as compared with subjects who do not develop the disease. Moreover, EEG theta frequency activity is quite different in these groups. This study investigated the correlation between biomarkers and memory performance.Methods: EEG α3/α2 power ratio and cortical thickness were computed in 74 adult subjects with prodromal Alzheimer’s disease. Twenty of these subjects also underwent assessment of blood perfusion by single-photon emission computed tomography (SPECT. Pearson’s r was used to assess the correlation between cortical thinning, brain perfusion, and memory impairment.Results: In the higher α3/α2 frequency power ratio group, greater cortical atrophy and lower regional perfusion in the temporoparietal cortex was correlated with an increase in EEG theta frequency. Memory impairment was more pronounced in the magnetic resonance imaging group and SPECT groups.Conclusion: A high EEG upper/low alpha power ratio was associated with cortical thinning and less perfusion in the temporoparietal area. Moreover, atrophy and less regional perfusion were significantly correlated with memory impairment in subjects with prodromal Alzheimer’s disease. The EEG upper/lower alpha frequency power ratio could be useful for identifying individuals at risk for progression to Alzheimer’s dementia and may be of value in the clinical context.Keywords: electroencephalography, perfusion, atrophy, temporoparietal network, memory deficits, hippocampal volume, mild cognitive impairment, Alzheimer’s disease

  20. A method for the direct injection and analysis of small volume human blood spots and plasma extracts containing high concentrations of organic solvents using revered-phase 2D UPLC/MS.

    Science.gov (United States)

    Rainville, Paul D; Simeone, Jennifer L; Root, Dan S; Mallet, Claude R; Wilson, Ian D; Plumb, Robert S

    2015-03-21

    The emergence of micro sampling techniques holds great potential to improve pharmacokinetic data quality, reduce animal usage, and save costs in safety assessment studies. The analysis of these samples presents new challenges for bioanalytical scientists, both in terms of sample processing and analytical sensitivity. The use of two dimensional LC/MS with, at-column-dilution for the direct analysis of highly organic extracts prepared from biological fluids such as dried blood spots and plasma is demonstrated. This technique negated the need to dry down and reconstitute, or dilute samples with water/aqueous buffer solutions, prior to injection onto a reversed-phase LC system. A mixture of model drugs, including bromhexine, triprolidine, enrofloxacin, and procaine were used to test the feasibility of the method. Finally an LC/MS assay for the probe pharmaceutical rosuvastatin was developed from dried blood spots and protein-precipitated plasma. The assays showed acceptable recovery, accuracy and precision according to US FDA guidelines. The resulting analytical method showed an increase in assay sensitivity of up to forty fold as compared to conventional methods by maximizing the amount loaded onto the system and the MS response for the probe pharmaceutical rosuvastatin from small volume samples.

  1. Plasma volume changes during hypoglycaemia

    DEFF Research Database (Denmark)

    Hilsted, J; Bendtsen, F; Christensen, N J

    1990-01-01

    To investigate whether previously reported changes in venous blood volume and composition induced by acute hypoglycaemia in humans are representative for the entire body we measured erythrocyte 51Cr content, haematocrit, plasma volume, intravascular albumin content and transcapillary escape rate...... of albumin in arterial and venous blood in seven healthy subjects before and during insulin-induced hypoglycaemia. In both vascular sites blood 51Cr content and the haematocrit increased, plasma volume and intravascular albumin content decreased and the transcapillary escape rate of albumin increased during...

  2. A radiocardiographic method for continuous registration of cardiac and pulmonary blood volume changes during exercise in normals, athlets and patients with latent cardiac insufficiency

    International Nuclear Information System (INIS)

    Hoeck, A.; Hoeck, A.; Vyska, K.; Freundlieb, C.; Feinendegen, L.E.

    1978-01-01

    Radiocardiographic methods thus far measure transit times, ejection fractions and ventricular wall motion. In the present study a method is described that permits continuous registration of exercise induced changes of cardiac and pulmonary volume and their ratio. 12 normal individuals, 15 athlets and 6 patients with latent cardiac insufficiency received i.v. 2-3 mCi 99m-Tc-Albumin. Fast serial scintigrams were taken in AP projection of the chest for 5 minutes at rest, during 5 minutes of graded exercise and 5 minutes rest again. The ROIs were the entire heart and left upper lung. The athlets showed, compared to normals, an exercise induced increase of the pulmonary counting rates and a decrease of the cardiac counting rates; the opposite phenomen was observed in patients with latent cardiac insufficiency. The ratio of the two counting rates amplyfied the signal of deviation. The method is simple, safe and highly sensitive for measuring changes in cardio-pulmonary hemodynamics. (author)

  3. Impact of transvaginal hydrolaparoscopy ovarian drilling on ovarian stromal blood flow and ovarian volume in clomiphene citrate-resistant PCOS patients: a case-control study.

    Science.gov (United States)

    Giampaolino, Pierluigi; Morra, Ilaria; De Rosa, Nicoletta; Cagnacci, Angelo; Pellicano, Massimiliano; Di Carlo, Costantino; Nappi, Carmine; Bifulco, Giuseppe

    2017-09-01

    Polycystic ovarian syndrome (PCOS) is the most common endocrine disorder in gynecology. In PCOS patients vascularization parameters are altered. Transvaginal hydrolaparoscopy (THL) is a mini-invasive approach for ovarian drilling in PCOS patients. In this study, we assessed the effect of ovarian drilling using THL on ovarian volume (OV) and vascularization index (VI) using 3D power Doppler ultrasonography in CC-resistant PCOS patients. A case-control study on 123 CC-resistant PCOS women who underwent THL ovarian drilling was performed. Patients underwent 3D ultrasound and power Doppler to measure VI, flow index (FI), vascularization flow index (VFI) and to evaluate OV before and after the procedure, at six months, and on the early follicular phase of the menstrual cycle. After THL ovarian drilling, OV and power Doppler flow indices were significantly reduced compared to pre-operative values (OV: 7.85 versus 11.72 cm 3 , p drilling seems to reduce OV and 3D power Doppler indices, and could therefore be a viable alternative to LOD in PCOS patients resistant to medical therapy.

  4. Subclinical Shed of Infectious Varicella zoster Virus in Astronauts

    Science.gov (United States)

    Cohrs, Randall J.; Mehta, Satish K.; Schmid, D. Scott; Gilden, Donald H.; Pierson, Duane L.

    2007-01-01

    Aerosol borne varicella zoster virus (VZV) enters the nasopharynx and replicates in tonsillar T-cells, resulting in viremia and varicella (chickenpox). Virus then becomes latent in cranial nerve, dorsal root and autonomic nervous system ganglia along the entire neuraxis (1). Decades later, as cell-mediated immunity to VZV declines (4), latent VZV can reactivate to produce zoster (shingles). Infectious VZV is present in patients with varicella or zoster, but shed of infectious virus in the absence of disease has not been shown. We previously detected VZV DNA in saliva of astronauts during and shortly after spaceflight, suggesting stress induced subclinical virus reactivation (3). We show here that VZV DNA as well as infectious virus in present in astronaut saliva. VZV DNA was detected in saliva during and after a 13-day spaceflight in 2 of 3 astronauts (Fig. panel A). Ten days before liftoff, there was a rise in serum anti-VZV antibody in subjects 1 and 2, consistent with virus reactivation. In subject 3, VZV DNA was not detected in saliva, and there was no rise in anti-VZV antibody titer. Subject 3 may have been protected from virus reactivation by having zoster DNA was detected in astronaut saliva months before spaceflight, or in saliva of 10 age/sex-matched healthy control subjects sampled on alternate days for 3 weeks (88 saliva samples). Saliva taken 2-6 days after landing from all 3 subjects was cultured on human fetal lung cells (Fig. panel B). Infectious VZV was recovered from saliva of subjects 1 and 2 on the second day after landing. Virus specificity was confirmed by antibody staining and DNA analysis which showed it to be VZV of European descent, common in the US (5). Further, both antibody staining and DNA PCR demonstrated that no HSV-1 was detected in any infected culture. This is the first report of infectious VZV shedding in the absence of clinical disease. Spaceflight presents a uniquely stressful environment which includes physical isolation and

  5. Cell shedding from X-irradiated multicellular spheroids of human lung carcinomas

    International Nuclear Information System (INIS)

    Sakata, K.; Okada, S.; Suzuki, N.; Majima, H.

    1991-01-01

    We studied the effect of radiation on cell shedding from the surface of multicellular spheroids. Spheroids were produced from two human lung cell lines, one adenocarcinoma (LCT1) and the other small cell carcinoma (LCT2), by using a liquid overlay culture technique. The number of cells shed from both kinds of spheroids did not change significantly when they were irradiated. The number of clonogenic cells shed from both kinds of irradiated spheroids decreased sharply as the dose of irradiation increases. There were no significant differences in clonogenic cell shedding per spheroid between LCT1 and LCT2 spheroids. 400 μm spheroids were more radioresistant to inhibition of clonogenic cell shedding than 250 μm spheroids. Shed cells were more radiosensitive than speroid cells. In these experiments, we did not obtain any results indicating that radiation enchances metastasis. (orig.) [de

  6. Large-Eddy Simulation of turbulent vortex shedding

    International Nuclear Information System (INIS)

    Archambeau, F.

    1995-06-01

    This thesis documents the development and application of a computational algorithm for Large-Eddy Simulation. Unusually, the method adopts a fully collocated variable storage arrangement and is applicable to complex, non-rectilinear geometries. A Reynolds-averaged Navier-Stokes algorithm has formed the starting point of the development, but has been modified substantially: the spatial approximation of convection is effected by an energy-conserving central-differencing scheme; a second-order time-marching Adams-Bashforth scheme has been introduced; the pressure field is determined by solving the pressure-Poisson equation; this equation is solved either by use of preconditioned Conjugate-Gradient methods or with the Generalised Minimum Residual method; two types of sub-grid scale models have been introduced and examined. The algorithm has been validated by reference to a hierarchy of unsteady flows of increasing complexity starting with unsteady lid-driven cavity flows and ending with 3-D turbulent vortex shedding behind a square prism. In the latter case, for which extensive experimental data are available, special emphasis has been put on examining the dependence of the results on mesh density, near-wall treatment and the nature of the sub-grid-scale model, one of which is an advanced dynamic model. The LES scheme is shown to return time-average and phase-averaged results which agree well with experimental data and which support the view that LES is a promising approach for unsteady flows dominated by large periodic structures. (author)

  7. Fabrication of Micromixers Utilizing Shedding Effect Induced by Electrokinetic Instability

    International Nuclear Information System (INIS)

    Fu, L-M; Tai, C-H; Tsai, C-H; Lin, C-H; Lee, C-Y

    2006-01-01

    This paper proposes a T-shaped micromixer featuring 45 deg. parallelogram barriers within the mixing channel. The proposed device obtains a rapid mixing of two sample fluids by means of the electrokinetic instability induced by shedding effect which is produced as an appropriate intensity of DC electric field of is applied. The proposed device uses a single high-voltage power source to simultaneously drive and mix the sample fluids. The effectiveness of the mixer is characterized experimentally as a function of the applied electrical field intensity and the extent to which the parallelogram barriers obstruct the mixing channel. The experimental results indicate that the mixing performance reaches 91.2% at a cross-section located 2.3 mm downstream of the T-junction when the barriers obstruct four-fifths of the channel width and an electrical field of 300V/cm is applied. The micromixing method presented in this study provides a simple low-cost solution to mixing problems in lab-on-a-chip systems

  8. CFTR Modulators: Shedding Light on Precision Medicine for Cystic Fibrosis

    Science.gov (United States)

    Lopes-Pacheco, Miquéias

    2016-01-01

    Cystic fibrosis (CF) is the most common life-threatening monogenic disease afflicting Caucasian people. It affects the respiratory, gastrointestinal, glandular and reproductive systems. The major cause of morbidity and mortality in CF is the respiratory disorder caused by a vicious cycle of obstruction of the airways, inflammation and infection that leads to epithelial damage, tissue remodeling and end-stage lung disease. Over the past decades, life expectancy of CF patients has increased due to early diagnosis and improved treatments; however, these patients still present limited quality of life. Many attempts have been made to rescue CF transmembrane conductance regulator (CFTR) expression, function and stability, thereby overcoming the molecular basis of CF. Gene and protein variances caused by CFTR mutants lead to different CF phenotypes, which then require different treatments to quell the patients’ debilitating symptoms. In order to seek better approaches to treat CF patients and maximize therapeutic effects, CFTR mutants have been stratified into six groups (although several of these mutations present pleiotropic defects). The research with CFTR modulators (read-through agents, correctors, potentiators, stabilizers and amplifiers) has achieved remarkable progress, and these drugs are translating into pharmaceuticals and personalized treatments for CF patients. This review summarizes the main molecular and clinical features of CF, emphasizes the latest clinical trials using CFTR modulators, sheds light on the molecular mechanisms underlying these new and emerging treatments, and discusses the major breakthroughs and challenges to treating all CF patients. PMID:27656143

  9. A vortex-shedding flowmeter based on IPMCs

    International Nuclear Information System (INIS)

    Pasquale, Giovanna Di; Pollicino, Antonino; Graziani, Salvatore; Strazzeri, Salvatore

    2016-01-01

    Ionic polymer–metal composites (IPMCs) are electroactive polymers that can be used both as sensors and actuators. They have been demonstrated for many potential applications, in wet and underwater environments. Applications in fields such as biomimetics, robotics, and aerospace, just to mention a few, have been proposed. In this paper, the sensing nature of IPMCs is used to develop a flowmeter based on the vortex shedding phenomenon. The system is described, and a model is proposed and verified. A setup has been realized, and data have been acquired for many working conditions. The performance of the sensing system has been investigated by using acquired experimental data. Water flux velocities in the range [0.38, 2.83] m s −1 have been investigated. This working range is comparable with ranges claimed for established technologies. Results show the suitability of the proposed system to work as a flowmeter. The proposed transducer is suitable for envisaged post-silicon applications, where the use of IPMCs gives the opportunity to realize a new generating polymeric flowmeter. This has potential applications in fields where properties of IPMCs such as low cost, usability, and disposability are relevant. (paper)

  10. Correlates of HIV-1 genital shedding in Tanzanian women.

    Directory of Open Access Journals (Sweden)

    Clare Tanton

    2011-03-01

    Full Text Available Understanding the correlates of HIV shedding is important to inform strategies to reduce HIV infectiousness. We examined correlates of genital HIV-1 RNA in women who were seropositive for both herpes simplex virus (HSV-2 and HIV-1 and who were enrolled in a randomised controlled trial of HSV suppressive therapy (aciclovir 400 mg b.i.d vs. placebo in Tanzania.Samples, including a cervico-vaginal lavage, were collected and tested for genital HIV-1 and HSV and reproductive tract infections (RTIs at randomisation and 6, 12 and 24 months follow-up. Data from all women at randomisation and women in the placebo arm during follow-up were analysed using generalised estimating equations to determine the correlates of cervico-vaginal HIV-1 RNA detection and load.Cervico-vaginal HIV-1 RNA was detected at 52.0% of 971 visits among 482 women, and was independently associated with plasma viral load, presence of genital ulcers, pregnancy, bloody cervical or vaginal discharge, abnormal vaginal discharge, cervical ectopy, Neisseria gonorrhoeae, Chlamydia trachomatis, Trichomonas vaginalis, an intermediate bacterial vaginosis score and HSV DNA detection. Similar factors were associated with genital HIV-1 RNA load.RTIs were associated with increased presence and quantity of genital HIV-1 RNA in this population. These results highlight the importance of integrating effective RTI treatment into HIV care services.

  11. Community-based Men's Sheds: promoting male health, wellbeing and social inclusion in an international context.

    Science.gov (United States)

    Cordier, Reinie; Wilson, Nathan J

    2014-09-01

    Males experience greater mortality and morbidity than females in most Western countries. The Australian and Irish National Male Health Policies aim to develop a framework to address this gendered health disparity. Men's Sheds have a distinct community development philosophy and are thus identified in both policies as an ideal location to address social isolation and positively impact the health and wellbeing of males who attend. The aim of this international cross-sectional survey was to gather information about Men's Sheds, the people who attend Men's Sheds, the activities at Men's Sheds, and the social and health dimensions of Men's Sheds. Results demonstrate that Men's Sheds are contributing a dual health and social role for a range of male subgroups. In particular, Men's Sheds have an outward social focus, supporting the social and mental health needs of men; health promotion and health literacy are key features of Men's Sheds. Men's Sheds have an important role to play in addressing the gendered health disparity that males face. They serve as an exemplar to health promotion professionals of a community development context where the aims of male health policy can be actualized as one part of a wider suite of global initiatives to reduce the gendered health disparity. © The Author (2013). Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Effect of antigen shedding on targeted delivery of immunotoxins in solid tumors from a mathematical model.

    Directory of Open Access Journals (Sweden)

    Youngshang Pak

    Full Text Available Most cancer-specific antigens used as targets of antibody-drug conjugates and immunotoxins are shed from the cell surface (Zhang & Pastan (2008 Clin. Cancer Res. 14: 7981-7986, although at widely varying rates and by different mechanisms (Dello Sbarba & Rovida (2002 Biol. Chem. 383: 69-83. Why many cancer-specific antigens are shed and how the shedding affects delivery efficiency of antibody-based protein drugs are poorly understood questions at present. Before a detailed numerical study, it was assumed that antigen shedding would reduce the efficacy of antibody-drug conjugates and immunotoxins. However, our previous study using a comprehensive mathematical model showed that antigen shedding can significantly improve the efficacy of the mesothelin-binding immunotoxin, SS1P (anti-mesothelin-Fv-PE38, and suggested that receptor shedding can be a general mechanism for enhancing the effect of inter-cellular signaling molecules. Here, we improved this model and applied it to both SS1P and another recombinant immunotoxin, LMB-2, which targets CD25. We show that the effect of antigen shedding is influenced by a number of factors including the number of antigen molecules on the cell surface and the endocytosis rate. The high shedding rate of mesothelin is beneficial for SS1P, for which the antigen is large in number and endocytosed rapidly. On the other hand, the slow shedding of CD25 is beneficial for LMB-2, for which the antigen is small in number and endocytosed slowly.

  13. Database of normal human cerebral blood flow measured by SPECT: II. Quantification of I-123-IMP studies with ARG method and effects of partial volume correction.

    Science.gov (United States)

    Inoue, Kentaro; Ito, Hiroshi; Shidahara, Miho; Goto, Ryoi; Kinomura, Shigeo; Sato, Kazunori; Taki, Yasuyuki; Okada, Ken; Kaneta, Tomohiro; Fukuda, Hiroshi

    2006-02-01

    The limited spatial resolution of SPECT causes a partial volume effect (PVE) and can lead to the significant underestimation of regional tracer concentration in the small structures surrounded by a low tracer concentration, such as the cortical gray matter of an atrophied brain. The aim of the present study was to determine, using 123I-IMP and SPECT, normal CBF of elderly subjects with and without PVE correction (PVC), and to determine regional differences in the effect of PVC and their association with the regional tissue fraction of the brain. Quantitative CBF SPECT using 123I-IMP was performed in 33 healthy elderly subjects (18 males, 15 females, 54-74 years old) using the autoradiographic method. We corrected CBF for PVE using segmented MR images, and analyzed quantitative CBF and regional differences in the effect of PVC using tissue fractions of gray matter (GM) and white matter (WM) in regions of interest (ROIs) placed on the cortical and subcortical GM regions and deep WM regions. The mean CBF in GM-ROIs were 31.7 +/- 6.6 and 41.0 +/- 8.1 ml/100 g/min for males and females, and in WM-ROIs, 18.2 +/- 0.7 and 22.9 +/- 0.8 ml/100 g/min for males and females, respectively. The mean CBF in GM-ROIs after PVC were 50.9 +/- 12.8 and 65.8 +/- 16.1 ml/100 g/min for males and females, respectively. There were statistically significant differences in the effect of PVC among ROIs, but not between genders. The effect of PVC was small in the cerebellum and parahippocampal gyrus, and it was large in the superior frontal gyrus, superior parietal lobule and precentral gyrus. Quantitative CBF in GM recovered significantly, but did not reach values as high as those obtained by invasive methods or in the H2(15)O PET study that used PVC. There were significant regional differences in the effect of PVC, which were considered to result from regional differences in GM tissue fraction, which is more reduced in the frontoparietal regions in the atrophied brain of the elderly.

  14. The association between the transfusion of small volumes of leucocyte-depleted red blood cells and outcomes in patients undergoing open-heart valve surgery.

    Science.gov (United States)

    Zittermann, Armin; Koster, Andreas; Faraoni, David; Börgermann, Jochen; Schirmer, Uwe; Gummert, Jan F

    2017-02-01

    The relationship between the transfusion of red blood cell (RBC) units and outcomes in patients undergoing cardiac surgery is the subject of intense debates. In this study, we investigated the relationship between the transfusion of 1-2 leucocyte-depleted (LD) RBC units and outcomes in patients undergoing open-heart valve surgery. The investigation encompassed consecutive patients undergoing open-heart valve surgery at our institution between July 2009 and March 2015 who received no (RBC- group) or 1-2 units of LD RBC (RBC+ group). End-points were 30-day mortality (primary), the incidence of in-hospital major organ dysfunctions and 1-year mortality (secondary). Propensity score (PS)-adjusted statistical analysis was used to assess the effect of RBC transfusion on end-points. Thirty-day mortality rate was 0.2% (3/1485) in the RBC- group and 0.4% (6/1672) in the RBC+ group, with a PS-adjusted odds ratio (OR) for 30-day mortality of 1.00 (95% CI: 0.21-4.83;P = 0.99). The two groups showed no significant differences in PS-adjusted ORs for major complications, such as stroke, low cardiac output syndrome, thoracic wound infection and prolonged mechanical ventilation (>24 h). The PS-adjusted ORs for prolonged intensive care unit stay (>48 h) were, however, significantly higher in the RBC+ group (OR = 1.34 [95%CI: 1.04-1.72; P = 0.02]) than in the RBC- group. One-year mortality was comparable between groups (PS-adjusted hazard ratio for the RBC+ group: 0.85 [95% CI: 0.42-1.72; P = 0.65]). Our data do not provide evidence that in patients undergoing valve surgery with cardiopulmonary bypass, transfusion of 1-2 units of LD RBC increases operative mortality, the incidence of postoperative complications or 1-year mortality. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  15. Donating Blood

    Science.gov (United States)

    ... The medical history includes questions that help blood bank staff decide if a person is healthy enough to donate blood. They'll ... Food and Drug Administration (FDA) regulates U.S. blood banks. All blood ... operating. Sometimes people who donate blood notice a few minor side ...

  16. Fetal blood drawing.

    Science.gov (United States)

    Hobbins, J C; Mahoney, M J

    1975-07-19

    A small sample of fetal blood suitable for studies of haemoglobin synthesis was obtained from a placental vessel under endoscopic visualisation in 23 of 26 patients in whom the procedure was attempted prior to second-trimester abortion. Fetal blood loss, calculated in 23 cases, was between 0-2 ml. and 2-5 ml., and fetal blood-volume depletion varied from 0-5% to 15%. No short-term ill-effects were demonstrated in mother or fetus in any of 16 patients in whom the injection of aborti-facient was postponed for between 16 and 24 hours after the procedure.

  17. Deterministic hydrodynamics: Taking blood apart

    Science.gov (United States)

    Davis, John A.; Inglis, David W.; Morton, Keith J.; Lawrence, David A.; Huang, Lotien R.; Chou, Stephen Y.; Sturm, James C.; Austin, Robert H.

    2006-10-01

    We show the fractionation of whole blood components and isolation of blood plasma with no dilution by using a continuous-flow deterministic array that separates blood components by their hydrodynamic size, independent of their mass. We use the technology we developed of deterministic arrays which separate white blood cells, red blood cells, and platelets from blood plasma at flow velocities of 1,000 μm/sec and volume rates up to 1 μl/min. We verified by flow cytometry that an array using focused injection removed 100% of the lymphocytes and monocytes from the main red blood cell and platelet stream. Using a second design, we demonstrated the separation of blood plasma from the blood cells (white, red, and platelets) with virtually no dilution of the plasma and no cellular contamination of the plasma. cells | plasma | separation | microfabrication

  18. Large-Eddy Simulation of turbulent vortex shedding

    Energy Technology Data Exchange (ETDEWEB)

    Archambeau, F

    1995-06-01

    This thesis documents the development and application of a computational algorithm for Large-Eddy Simulation. Unusually, the method adopts a fully collocated variable storage arrangement and is applicable to complex, non-rectilinear geometries. A Reynolds-averaged Navier-Stokes algorithm has formed the starting point of the development, but has been modified substantially: the spatial approximation of convection is effected by an energy-conserving central-differencing scheme; a second-order time-marching Adams-Bashforth scheme has been introduced; the pressure field is determined by solving the pressure-Poisson equation; this equation is solved either by use of preconditioned Conjugate-Gradient methods or with the Generalised Minimum Residual method; two types of sub-grid scale models have been introduced and examined. The algorithm has been validated by reference to a hierarchy of unsteady flows of increasing complexity starting with unsteady lid-driven cavity flows and ending with 3-D turbulent vortex shedding behind a square prism. In the latter case, for which extensive experimental data are available, special emphasis has been put on examining the dependence of the results on mesh density, near-wall treatment and the nature of the sub-grid-scale model, one of which is an advanced dynamic model. The LES scheme is shown to return time-average and phase-averaged results which agree well with experimental data and which support the view that LES is a promising approach for unsteady flows dominated by large periodic structures. (author) 87 refs.

  19. A study on the frictional response of reptilian shed skin

    International Nuclear Information System (INIS)

    Abdel-Aal, H A; Vargiolu, R; Zahouani, H; Mansori, M El

    2011-01-01

    Deterministic surfaces are constructs of which profile, topography and textures are integral to the function of the system they enclose. They are designed to yield a predetermined tribological response. Developing such entities relies on controlling the structure of the rubbing interface so that, not only the surface is of optimized topography, but also is able to self-adjust its tribological behaviour according to the evolution of sliding conditions. In seeking inspirations for such designs, many engineers are turning toward the biological world to study the construction and behaviour of bio-analogues, and to probe the role surface topography assumes in conditioning of frictional response. That is how a bio-analogue can self-adjust its tribological response to adapt to habitat constraints. From a tribological point of view, Squamate Reptiles, offer diverse examples where surface texturing, submicron and nano-scale features, achieves frictional regulation. In this paper, we study the frictional response of shed skin obtained from a snake (Python regius). The study employed a specially designed tribo-acoustic probe capable of measuring the coefficient of friction and detecting the acoustical behavior of the skin in vivo. The results confirm the anisotropy of the frictional response of snakes. The coefficient of friction depends on the direction of sliding: the value in forward motion is lower than that in the backward direction. Diagonal and side winding motion induces a different value of the friction coefficient. We discuss the origin of such a phenomenon in relation to surface texturing and study the energy constraints, implied by anisotropic friction, on the motion of the reptile.

  20. A study on the frictional response of reptilian shed skin

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Aal, H A [Arts et Metier ParisTech, Rue Saint Dominique BP 508, 51006 Chalons-en-Champagne (France); Vargiolu, R; Zahouani, H [Laboratoire de Tribology et Dynamique des Systemes, UMR CNRS 5513, ENI Saint Etienne - Ecole Centrale de Lyon -36 Avenue Guy de Collongue, 69131 Ecully cedex. France (France); Mansori, M El, E-mail: Hisham.abdel-aal@ensam.eu [Ecole Nationale Superieure d' Arts et Metiers, 2, cours des Arts et Metiers - 13617 Aix en Provence cedex 1 (France)

    2011-08-19

    Deterministic surfaces are constructs of which profile, topography and textures are integral to the function of the system they enclose. They are designed to yield a predetermined tribological response. Developing such entities relies on controlling the structure of the rubbing interface so that, not only the surface is of optimized topography, but also is able to self-adjust its tribological behaviour according to the evolution of sliding conditions. In seeking inspirations for such designs, many engineers are turning toward the biological world to study the construction and behaviour of bio-analogues, and to probe the role surface topography assumes in conditioning of frictional response. That is how a bio-analogue can self-adjust its tribological response to adapt to habitat constraints. From a tribological point of view, Squamate Reptiles, offer diverse examples where surface texturing, submicron and nano-scale features, achieves frictional regulation. In this paper, we study the frictional response of shed skin obtained from a snake (Python regius). The study employed a specially designed tribo-acoustic probe capable of measuring the coefficient of friction and detecting the acoustical behavior of the skin in vivo. The results confirm the anisotropy of the frictional response of snakes. The coefficient of friction depends on the direction of sliding: the value in forward motion is lower than that in the backward direction. Diagonal and side winding motion induces a different value of the friction coefficient. We discuss the origin of such a phenomenon in relation to surface texturing and study the energy constraints, implied by anisotropic friction, on the motion of the reptile.

  1. Replication and shedding kinetics of infectious hematopoietic necrosis virus in juvenile rainbow trout

    Science.gov (United States)

    Wargo, Andrew R.; Scott, Robert J.; Kerr, Benjamin; Kurath, Gael

    2017-01-01

    Viral replication and shedding are key components of transmission and fitness, the kinetics of which are heavily dependent on virus, host, and environmental factors. To date, no studies have quantified the shedding kinetics of infectious hematopoietic necrosis virus (IHNV) in rainbow trout (Oncorhynchus mykiss), or how they are associated with replication, making it difficult to ascertain the transmission dynamics of this pathogen of high agricultural and conservation importance. Here, the replication and shedding kinetics of two M genogroup IHNV genotypes were examined in their naturally co-evolved rainbow trout host. Within host virus replication began rapidly, approaching maximum values by day 3 post-infection, after which viral load was maintained or gradually dropped through day 7. Host innate immune response measured as stimulation of Mx-1 gene expression generally followed within host viral loads. Shedding also began very quickly and peaked within 2 days, defining a generally uniform early peak period of shedding from 1 to 4 days after exposure to virus. This was followed by a post-peak period where shedding declined, such that the majority of fish were no longer shedding by day 12 post-infection. Despite similar kinetics, the average shedding rate over the course of infection was significantly lower in mixed compared to single genotype infections, suggesting a competition effect, however, this did not significantly impact the total amount of virus shed. The data also indicated that the duration of shedding, rather than peak amount of virus shed, was correlated with fish mortality. Generally, the majority of virus produced during infection appeared to be shed into the environment rather than maintained in the host, although there was more retention of within host virus during the post-peak period. Viral virulence was correlated with shedding, such that the more virulent of the two genotypes shed more total virus. This fundamental understanding of IHNV

  2. Comparison of three nonlinear models to describe long-term tag shedding by lake trout

    Science.gov (United States)

    Fabrizio, Mary C.; Swanson, Bruce L.; Schram, Stephen T.; Hoff, Michael H.

    1996-01-01

    We estimated long-term tag-shedding rates for lake trout Salvelinus namaycush using two existing models and a model we developed to account for the observed permanence of some tags. Because tag design changed over the course of the study, we examined tag-shedding rates for three types of numbered anchor tags (Floy tags FD-67, FD-67C, and FD-68BC) and an unprinted anchor tag (FD-67F). Lake trout from the Gull Island Shoal region, Lake Superior, were double-tagged, and subsequent recaptures were monitored in annual surveys conducted from 1974 to 1992. We modeled tag-shedding rates, using time at liberty and probabilities of tag shedding estimated from fish released in 1974 and 1978–1983 and later recaptured. Long-term shedding of numbered anchor tags in lake trout was best described by a nonlinear model with two parameters: an instantaneous tag-shedding rate and a constant representing the proportion of tags that were never shed. Although our estimates of annual shedding rates varied with tag type (0.300 for FD-67, 0.441 for FD-67C, and 0.656 for FD-68BC), differences were not significant. About 36% of tags remained permanently affixed to the fish. Of the numbered tags that were shed (about 64%), two mechanisms contributed to tag loss: disintegration and dislodgment. Tags from about 11% of recaptured fish had disintegrated, but most tags were dislodged. Unprinted tags were shed at a significant but low rate immediately after release, but the long-term, annual shedding rate of these tags was only 0.013. Compared with unprinted tags, numbered tags dislodged at higher annual rates; we hypothesized that this was due to the greater frictional drag associated with the larger cross-sectional area of numbered tags.

  3. What's Blood?

    Science.gov (United States)

    ... Body Make Blood? It's not made in a kitchen, but blood has ingredients, just like a recipe. ... these ingredients together and you have blood — an essential part of the circulatory system. Thanks to your ...

  4. Blood typing

    Science.gov (United States)

    ... detect these minor antigens. It is done before transfusions, except in emergency situations. Alternative Names Cross matching; Rh typing; ABO blood typing; Blood group; Anemia - immune hemolytic blood type; ...

  5. Blood smear

    Science.gov (United States)

    ... smear URL of this page: //medlineplus.gov/ency/article/003665.htm Blood smear To use the sharing features on this ... view of cellular parasites Malaria, photomicrograph of cellular parasites Red blood cells, sickle cells Red blood cells, sickle and ...

  6. Mean Platelet Volume, Red Cell Distribution Width to Platelet Count Ratio, Globulin Platelet Index, and 16 Other Indirect Noninvasive Fibrosis Scores: How Much Do Routine Blood Tests Tell About Liver Fibrosis in Chronic Hepatitis C?

    Science.gov (United States)

    Thandassery, Ragesh B; Al Kaabi, Saad; Soofi, Madiha E; Mohiuddin, Syed A; John, Anil K; Al Mohannadi, Muneera; Al Ejji, Khalid; Yakoob, Rafie; Derbala, Moutaz F; Wani, Hamidullah; Sharma, Manik; Al Dweik, Nazeeh; Butt, Mohammed T; Kamel, Yasser M; Sultan, Khaleel; Pasic, Fuad; Singh, Rajvir

    2016-07-01

    Many indirect noninvasive scores to predict liver fibrosis are calculated from routine blood investigations. Only limited studies have compared their efficacy head to head. We aimed to compare these scores with liver biopsy fibrosis stages in patients with chronic hepatitis C. From blood investigations of 1602 patients with chronic hepatitis C who underwent a liver biopsy before initiation of antiviral treatment, 19 simple noninvasive scores were calculated. The area under the receiver operating characteristic curves and diagnostic accuracy of each of these scores were calculated (with reference to the Scheuer staging) and compared. The mean age of the patients was 41.8±9.6 years (1365 men). The most common genotype was genotype 4 (65.6%). Significant fibrosis, advanced fibrosis, and cirrhosis were seen in 65.1%, 25.6, and 6.6% of patients, respectively. All the scores except the aspartate transaminase (AST) alanine transaminase ratio, Pohl score, mean platelet volume, fibro-alpha, and red cell distribution width to platelet count ratio index showed high predictive accuracy for the stages of fibrosis. King's score (cutoff, 17.5) showed the highest predictive accuracy for significant and advanced fibrosis. King's score, Göteborg university cirrhosis index, APRI (the AST/platelet count ratio index), and Fibrosis-4 (FIB-4) had the highest predictive accuracy for cirrhosis, with the APRI (cutoff, 2) and FIB-4 (cutoff, 3.25) showing the highest diagnostic accuracy.We derived the study score 8.5 - 0.2(albumin, g/dL) +0.01(AST, IU/L) -0.02(platelet count, 10/L), which at a cutoff of >4.7 had a predictive accuracy of 0.868 (95% confidence interval, 0.833-0.904) for cirrhosis. King's score for significant and advanced fibrosis and the APRI or FIB-4 score for cirrhosis could be the best simple indirect noninvasive scores.

  7. Genetic relationship between wool shedding in ewe-lambs and ewes

    Science.gov (United States)

    Interest in reducing labor costs related to shearing has led to the development of breeds that naturally shed their wool annually. This goal has been achieved by introducing hair-sheep genetics. These developments are relatively recent and thus the genetic underpinnings of wool shedding (WS) are not...

  8. Strongyle egg shedding consistency in horses on farms using selective therapy in Denmark

    DEFF Research Database (Denmark)

    Nielsen, Martin Krarup; Haaning, Niels; Olsen, Susanne Nautrup

    2006-01-01

    Knowledge of horses that shed the same number of strongyle eggs over time can lead to the optimization of parasite control strategies. This study evaluated shedding of strongyle eggs in 424 horses on 10 farms whan a selective anthelmintic treatment regime was used over a 3-year period....

  9. Prolonged Shedding of Human Parechovirus in Feces of Young Children after Symptomatic Infection

    NARCIS (Netherlands)

    Wildenbeest, Joanne G; Benschop, Kimberley S M; Bouma-de Jongh, Saskia; Wolthers, Katja C; Pajkrt, Dasja

    2016-01-01

    After symptomatic human parechovirus (HPeV) infection in infants, the duration of (mostly asymptomatic) shedding in feces was 2-24 weeks (median 58 days). HPeV cycle threshold value could neither differentiate between symptomatic disease and asymptomatic shedding nor between severe and mild disease

  10. Application of computational intelligence techniques for load shedding in power systems: A review

    International Nuclear Information System (INIS)

    Laghari, J.A.; Mokhlis, H.; Bakar, A.H.A.; Mohamad, Hasmaini

    2013-01-01

    Highlights: • The power system blackout history of last two decades is presented. • Conventional load shedding techniques, their types and limitations are presented. • Applications of intelligent techniques in load shedding are presented. • Intelligent techniques include ANN, fuzzy logic, ANFIS, genetic algorithm and PSO. • The discussion and comparison between these techniques are provided. - Abstract: Recent blackouts around the world question the reliability of conventional and adaptive load shedding techniques in avoiding such power outages. To address this issue, reliable techniques are required to provide fast and accurate load shedding to prevent collapse in the power system. Computational intelligence techniques, due to their robustness and flexibility in dealing with complex non-linear systems, could be an option in addressing this problem. Computational intelligence includes techniques like artificial neural networks, genetic algorithms, fuzzy logic control, adaptive neuro-fuzzy inference system, and particle swarm optimization. Research in these techniques is being undertaken in order to discover means for more efficient and reliable load shedding. This paper provides an overview of these techniques as applied to load shedding in a power system. This paper also compares the advantages of computational intelligence techniques over conventional load shedding techniques. Finally, this paper discusses the limitation of computational intelligence techniques, which restricts their usage in load shedding in real time

  11. Blood Culture (For Parents)

    Science.gov (United States)

    ... Metabolic Panel (BMP) Blood Test: Complete Blood Count Basic Blood Chemistry Tests Getting a Blood Test (Video) Blood Test: Basic Metabolic Panel Blood Test: Comprehensive Metabolic Panel Blood ...

  12. Under-Frequency Load Shedding Technique Considering Event-Based for an Islanded Distribution Network

    Directory of Open Access Journals (Sweden)

    Hasmaini Mohamad

    2016-06-01

    Full Text Available One of the biggest challenge for an islanding operation is to sustain the frequency stability. A large power imbalance following islanding would cause under-frequency, hence an appropriate control is required to shed certain amount of load. The main objective of this research is to develop an adaptive under-frequency load shedding (UFLS technique for an islanding system. The technique is designed considering an event-based which includes the moment system is islanded and a tripping of any DG unit during islanding operation. A disturbance magnitude is calculated to determine the amount of load to be shed. The technique is modeled by using PSCAD simulation tool. A simulation studies on a distribution network with mini hydro generation is carried out to evaluate the UFLS model. It is performed under different load condition: peak and base load. Results show that the load shedding technique have successfully shed certain amount of load and stabilized the system frequency.

  13. Experimental investigation on cavitating flow shedding over an axisymmetric blunt body

    Science.gov (United States)

    Hu, Changli; Wang, Guoyu; Huang, Biao

    2015-03-01

    Nowadays, most researchers focus on the cavity shedding mechanisms of unsteady cavitating flows over different objects, such as 2D/3D hydrofoils, venturi-type section, axisymmetric bodies with different headforms, and so on. But few of them pay attention to the differences of cavity shedding modality under different cavitation numbers in unsteady cavitating flows over the same object. In the present study, two kinds of shedding patterns are investigated experimentally. A high speed camera system is used to observe the cavitating flows over an axisymmetric blunt body and the velocity fields are measured by a particle image velocimetry (PIV) technique in a water tunnel for different cavitation conditions. The U-type cavitating vortex shedding is observed in unsteady cavitating flows. When the cavitation number is 0.7, there is a large scale cavity rolling up and shedding, which cause the instability and dramatic fluctuation of the flows, while at cavitation number of 0.6, the detached cavities can be conjunct with the attached part to induce the break-off behavior again at the tail of the attached cavity, as a result, the final shedding is in the form of small scale cavity and keeps a relatively steady flow field. It is also found that the interaction between the re-entrant flow and the attached cavity plays an important role in the unsteady cavity shedding modality. When the attached cavity scale is insufficient to overcome the re-entrant flow, it deserves the large cavity rolling up and shedding just as that at cavitation number of 0.7. Otherwise, the re-entrant flow is defeated by large enough cavity to induce the cavity-combined process and small scale cavity vortexes shedding just as that of the cavitation number of 0.6. This research shows the details of two different cavity shedding modalities which is worthful and meaningful for the further study of unsteady cavitation.

  14. Correlation between left ventricular diastolic function before and after valve replacement surgery and myocardial ultrastructural changes in patients with left ventricular volume-overloaded valvular heart diseases; Evaluation with gated blood pool scintigraphy using [sup 99m]Tc

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Tomiro (Okayama Univ. (Japan). School of Medicine)

    1993-06-01

    Left ventricular (LV) diastolic functions in 23 patients with aortic regurgitation (AR) and 22 patients with mitral regurgitation (MR) were evaluated by gated blood pool scintigraphy. LV myocardial biopsy was performed during open heart surgery, and LV myocardial ultrastructural changes were evaluated by electron microscope. Correlation between LV diastolic function and myocardial ultrastructural changes was examined. It was suggested that preoperative LV diastolic dysfunction occurred earlier than LV systolic dysfunction in patients with AR and MR. LV early diastolic dysfunction was especially significant in patients with AR. LV systolic function was significantly improved postoperatively compared with LV diastolic function in patients with AR and MR. It was suggested that LV interstitial fibrosis caused LV diastolic dysfunction in patients with AR and MR, and insufficiency of myocardial thickening as compensation in patients with MR. It was presumed that LV diastolic dysfunction was irreversible in patients with AR and MR in the distant postoperative period due to persistence of the preoperative myocardial ultrastructural change, e.g., interstitial fibrosis. These LV diastolic indices measured by gated pool scintigraphy were useful in predicting LV ultrastructural changes and postoperative LV dysfunction in patients with LV volume-overloaded valvular heart disease. (author).

  15. Application of histogram analysis for the evaluation of vascular permeability in glioma by the K2 parameter obtained with the dynamic susceptibility contrast method: Comparisons with Ktrans obtained with the dynamic contrast enhance method and cerebral blood volume.

    Science.gov (United States)

    Taoka, Toshiaki; Kawai, Hisashi; Nakane, Toshiki; Hori, Saeka; Ochi, Tomoko; Miyasaka, Toshiteru; Sakamoto, Masahiko; Kichikawa, Kimihiko; Naganawa, Shinji

    2016-09-01

    The "K2" value is a factor that represents the vascular permeability of tumors and can be calculated from datasets obtained with the dynamic susceptibility contrast (DSC) method. The purpose of the current study was to correlate K2 with Ktrans, which is a well-established permeability parameter obtained with the dynamic contrast enhance (DCE) method, and determine the usefulness of K2 for glioma grading with histogram analysis. The subjects were 22 glioma patients (Grade II: 5, III: 6, IV: 11) who underwent DSC studies, including eight patients in which both DSC and DCE studies were performed on separate days within 10days. We performed histogram analysis of regions of interest of the tumors and acquired 20th percentile values for leakage-corrected cerebral blood volume (rCBV20%ile), K2 (K220%ile), and for patients who underwent a DCE study, Ktrans (Ktrans20%ile). We evaluated the correlation between K220%ile and Ktrans20%ile and the statistical difference between rCBV20%ile and K220%ile. We found a statistically significant correlation between K220%ile and Ktrans20%ile (r=0.717, pK220%ile showed a statistically significant (pK2 value calculated from the DSC dataset, which can be obtained with a short acquisition time, showed a correlation with Ktrans obtained with the DCE method and may be useful for glioma grading when analyzed with histogram analysis. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Volume and mass measurements of liquids

    International Nuclear Information System (INIS)

    Zander, M.

    1987-12-01

    The report comprises the 10 lectures given at the 74th PTB seminar, which represent the state of the art in the field of liquid flow measurement. The lectures deal with the overflow-pipette as the primary volume standard of PTB, gas elimination devices (compulsory in measuring assemblies with volume meters), measuring assemblies for the reception of milk, electromagnetic flowmeters, vortex-shedding meters, indirect mass measurement from volume and density, direct mass measurement (coriolis flowmeters), pipeline-measurements, level measurement at storage tanks with conventional and optical methods and a development aid project for the set up of test rigs in India. (orig.) [de

  17. Practical dosimetric aspects of blood and blood product irradiation

    International Nuclear Information System (INIS)

    Fearon, T.C.; Luban, N.L.

    1986-01-01

    The method of choice to reduce susceptibility to transfusion-transmitted graft-versus-host disease is irradiation of allogenic blood and blood products for transfusion to immunosuppressed recipients. Optimal irradiation requires delivery of a known and homogeneous absorbed dose. The use of absorbed dose in air measured at the center of the irradiation volume without proper compensation for sample absorption can lead to approximately 20 percent underexposure. A lucite cylinder was used to provide the delivery of a homogeneous irradiation dose to blood products of different volumes by allowing rotation of the product

  18. Salmonella fecal shedding and immune responses are dose- and serotype- dependent in pigs.

    Directory of Open Access Journals (Sweden)

    Renata Ivanek

    Full Text Available Despite the public health importance of Salmonella infection in pigs, little is known about the associated dynamics of fecal shedding and immunity. In this study, we investigated the transitions of pigs through the states of Salmonella fecal shedding and immune response post-Salmonella inoculation as affected by the challenge dose and serotype. Continuous-time multistate Markov models were developed using published experimental data. The model for shedding had four transient states, of which two were shedding (continuous and intermittent shedding and two non-shedding (latency and intermittent non-shedding, and one absorbing state representing permanent cessation of shedding. The immune response model had two transient states representing responses below and above the seroconversion level. The effects of two doses [low (0.65×10(6 CFU/pig and high (0.65×10(9 CFU/pig] and four serotypes (Salmonella Yoruba, Salmonella Cubana, Salmonella Typhimurium, and Salmonella Derby on the models' transition intensities were evaluated using a proportional intensities model. Results indicated statistically significant effects of the challenge dose and serotype on the dynamics of shedding and immune response. The time spent in the specific states was also estimated. Continuous shedding was on average 10-26 days longer, while intermittent non-shedding was 2-4 days shorter, in pigs challenged with the high compared to low dose. Interestingly, among pigs challenged with the high dose, the continuous and intermittent shedding states were on average up to 10-17 and 3-4 days longer, respectively, in pigs infected with S. Cubana compared to the other three serotypes. Pigs challenged with the high dose of S. Typhimurium or S. Derby seroconverted on average up to 8-11 days faster compared to the low dose. These findings highlight that Salmonella fecal shedding and immune response following Salmonella challenge are dose- and serotype-dependent and that the detection of

  19. Screening Test for Shed Skin Cells by Measuring the Ratio of Human DNA to Staphylococcus epidermidis DNA.

    Science.gov (United States)

    Nakanishi, Hiroaki; Ohmori, Takeshi; Hara, Masaaki; Takahashi, Shirushi; Kurosu, Akira; Takada, Aya; Saito, Kazuyuki

    2016-05-01

    A novel screening method for shed skin cells by detecting Staphylococcus epidermidis (S. epidermidis), which is a resident bacterium on skin, was developed. Staphylococcus epidermidis was detected using real-time PCR. Staphylococcus epidermidis was detected in all 20 human skin surface samples. Although not present in blood and urine samples, S. epidermidis was detected in 6 of 20 saliva samples, and 5 of 18 semen samples. The ratio of human DNA to S. epidermidisDNA was significantly smaller in human skin surface samples than in saliva and semen samples in which S. epidermidis was detected. Therefore, although skin cells could not be identified by detecting only S. epidermidis, they could be distinguished by measuring the S. epidermidis to human DNA ratio. This method could be applied to casework touch samples, which suggests that it is useful for screening whether skin cells and human DNA are present on potential evidentiary touch samples. © 2016 American Academy of Forensic Sciences.

  20. Early Diagnosis of Congenital Trypanosoma cruzi Infection, Using Shed Acute Phase Antigen, in Ushuaia, Tierra del Fuego, Argentina

    Science.gov (United States)

    Mallimaci, María Cristina; Sosa-Estani, Sergio; Russomando, Graciela; Sanchez, Zunilda; Sijvarger, Carina; Alvarez, Isabel Marcela; Barrionuevo, Lola; Lopez, Carlos; Segura, Elsa Leonor

    2010-01-01

    Chagas' disease, or American trypanosomiasis, is caused by the protozoan parasite Trypanasoma cruzi. It is estimated that 15,000 new cases of congenital T. cruzi transmission occur in the Americas each year. The aim of this study was to estimate the rate of congenital T. cruzi infection in infants born to infected women living in Ushuaia, Argentina, as well to assess a serologic test using Shed Acute Phase Antigen (SAPA) for a timely diagnosis of congenital infection. The rate of congenital infection among children in the study was 4.4% (3/68). Our results show that for infants younger than 30 days of age, matched blood samples from mother and infant were capable of identifying congenital transmission of infection using an enzyme-linked immunosorbent assay with SAPA. For infants older than 3 months, congenital infection could be ruled out using the same procedure. PMID:20064996

  1. Engineering Extreme Hydrophobic and Super Slippery Water Shedding Surfaces

    Science.gov (United States)

    McHale, Glen

    2017-04-01

    The intrinsic water repellency of a material is fundamentally determined by its surface chemistry, but alone this does not determine the ability of a surface to shed water. Physical factors such as the surface texture/topography, rigidity/flexibility, granularity/porosity combined with the intrinsic wetting properties of the liquid with the surface and whether it is infused by a lubricating liquid are equally important. In this talk I will outline fundamental, but simple, ideas on the topographic enhancement of surface chemistry to create superhydrophobicity, the adhesion of particles to liquid-air interfaces to create liquid marbles, elastocapillarity to create droplet wrapping, and lubricant impregnated surfaces to create completely mobile droplets [1-3]. I will discuss how these ideas have their origins in natural systems and surfaces, such as Lotus leaves, galling aphids and the Nepenthes pitcher plant. I will show how we have applied these concepts to study the wetting of granular systems, such as sand, to understand extreme soil water repellency. I will argue that relaxing the assumption that a solid substrate is fixed in shape and arrangement, can lead to the formation of liquid marbles, whereby a droplet self-coats in a hydrophobic powder/grains. I will show that the concepts of wetting and porosity blur as liquids penetrate into a porous or granular substrate. I will also discuss how lubricant impregnated super slippery surfaces can be used to study a pure constant contact angle mode of droplet evaporation [4]. Finally, I will show dewetting of a surface is not simply a video reversal of wetting [5], and I will give an example of the use of perfect hydrophobicity using the Leidenfrost effect to create a new type of low friction mechanical and hear engine [6]. References: [1] Shirtcliffe, N. J., et al., An introduction to superhydrophobicity. Advances in Colloid and Interface Science, vol. 161, pp.124-138 (2010). [2] McHale, G. & Newton, M. I. Liquid

  2. Kinetics of viral shedding provide insights into the epidemiology of viral hemorrhagic septicemia in Pacific herring

    Science.gov (United States)

    Hershberger, Paul K.; Gregg, Jacob L.; Winton, James R.; Grady, Courtney; Collins, Rachael

    2010-01-01

    Losses from infectious diseases are an important component of natural mortality among marine fish species, but factors controlling the ecology of these diseases and their potential responses to anthropogenic changes are poorly understood. We used viral hemorrhagic septicemia virus (VHSV) and a laboratory stock of Pacific herring Clupea pallasii to investigate the kinetics of viral shedding and its effect on disease transmission and host mortality. Outbreaks of acute disease, accompanied by mortality and viral shedding, were initiated after waterborne exposure of herring to concentrations of VHSV as low as 101 plaque-forming units (pfu) ml–1. Shed virus in flow-through tanks was first detected 4 to 5 d post-exposure, peaked after 6 to 10 d, and was no longer detected after 16 d. Shedding rates, calculated from density, flow and waterborne virus titer reached 1.8 to 5.0 × 108 pfu fish–1 d–1. Onset of viral shedding was dose-dependent and preceded initial mortality by 2 d. At 21 d, cumulative mortality in treatment groups ranged from 81 to 100% and was dependent not on challenge dose, but on the kinetics and level of viral shedding by infected fish in the tank. Possible consequences of the viral shedding and disease kinetics are discussed in the context of epizootic initiation and perpetuation among populations of wild Pacific herring.

  3. The Transition from Thick to Thin Plate Wake Physics: Whither Vortex Shedding?

    Science.gov (United States)

    Rai, Man Mohan

    2016-01-01

    The near and very near wake of a flat plate with a circular trailing edge is investigated with data from direct numerical simulations. Computations were performed for six different combinations of the Reynolds numbers based on plate thickness (D) and boundary layer momentum thickness upstream of the trailing edge (theta). Unlike the case of the cylinder, these Reynolds numbers are independent parameters for the flat plate. The separating boundary layers are turbulent in all the cases investigated. One objective of the study is to understand the changes in the wake vortex shedding process as the plate thickness is reduced (increasing theta/D). The value of D varies by a factor of 16 and that of theta by approximately 5 in the computations. Vortex shedding is vigorous in the low theta/D cases with a substantial decrease in shedding intensity in the large theta/D cases. Other shedding characteristics are also significantly altered with increasing theta/D. A visualization of the shedding process in the different cases is provided and discussed. The basic shedding mechanism is explored in depth. The effect of changing theta/D on the time-averaged, near-wake velocity statistics is also discussed. A functional relationship between the shedding frequency and the Reynolds numbers mentioned above is obtained.

  4. Persistent genital herpes simplex virus-2 shedding years following the first clinical episode.

    Science.gov (United States)

    Phipps, Warren; Saracino, Misty; Magaret, Amalia; Selke, Stacy; Remington, Mike; Huang, Meei-Li; Warren, Terri; Casper, Corey; Corey, Lawrence; Wald, Anna

    2011-01-15

    Patients with newly acquired genital herpes simplex virus 2 (HSV-2) infection have virus frequently detected at the genital mucosa. Rates of genital shedding initially decrease over time after infection, but data on long-term viral shedding are lacking. For this study, 377 healthy adults with history of symptomatic genital HSV-2 infection collected anogenital swabs for HSV-2 DNA polymerase chain reaction for at least 30 consecutive days. Time since first genital herpes episode was significantly associated with reduced genital shedding. Total HSV shedding occurred on 33.6% of days in participants <1 year, 20.6% in those 1-9 years, and 16.7% in those ≥10 years from first episode. Subclinical HSV shedding occurred on 26.2% of days among participants <1 year, 13.1% in those 1-9 years, and 9.3% in those ≥10 years from first episode. On days with HSV detection, mean quantity was 4.9 log₁₀ copies/mL for those <1 year, 4.7 log₁₀ copies/mL among those 1-9 years, and 4.6 log₁₀ copies/mL among those ≥10 years since first episode. Rates of total and subclinical HSV-2 shedding decrease after the first year following the initial clinical episode. However, viral shedding persists at high rates and copy numbers years after infection, and therefore may pose continued risk of HSV-2 transmission to sexual partners.

  5. Microparticle Shedding by Erythrocytes, Monocytes and Vascular Smooth Muscular Cells Is Reduced by Aspirin in Diabetic Patients.

    Science.gov (United States)

    Chiva-Blanch, Gemma; Suades, Rosa; Padró, Teresa; Vilahur, Gemma; Peña, Esther; Ybarra, Juan; Pou, Jose M; Badimon, Lina

    2016-07-01

    Diabetes mellitus is associated with an enhanced risk for cardiovascular disease and its prevalence is increasing. Diabetes induces metabolic stress on blood and vascular cells, promoting platelet activation and vascular dysfunction. The level of vascular cell activation can be measured by the number and phenotype of microparticles found in the circulation. The aim of this study was to investigate the effect of a platelet-inhibitory dose of aspirin on the number and type of microparticles shed to the circulation. Forty-three diabetic patients were enrolled in the study and received a daily dose of 100mg of aspirin for 10 days to cover the average platelet life-span in the circulation. Before and after the intervention period, circulating microparticles were characterized and quantified by flow cytometry. Type 1 diabetic patients had about twice the number of tissue factor-positive circulating microparticles (derived both from platelets and monocytes) and endothelial-derived E-selectin positive microparticles than type 2 diabetic patients. Aspirin therapy significantly inhibited platelets since cyclooxygenase 1 derived thromboxane generation levels were reduced by 99%. Microparticles derived from erythrocytes, activated monocytes, and smooth muscle cells were significantly reduced after 10 days of aspirin administration. These results indicate that: a) vascular and blood cells in type 1 diabetic patients are exposed to more sustained stress shown by their specific microparticle origin and levels; b) aspirin therapy inhibits vascular wall cell activation and microparticle shedding, and c) the effects of aspirin are similar in type 1 and 2 diabetes. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  6. Hot-Wire Calibration at Low Velocities: Revisiting the Vortex Shedding Method

    Directory of Open Access Journals (Sweden)

    Sohrab S. Sattarzadeh

    2013-01-01

    Full Text Available The necessity to calibrate hot-wire probes against a known velocity causes problems at low velocities, due to the inherent inaccuracy of pressure transducers at low differential pressures. The vortex shedding calibration method is in this respect a recommended technique to obtain calibration data at low velocities, due to its simplicity and accuracy. However, it has mainly been applied in a low and narrow Reynolds number range known as the laminar vortex shedding regime. Here, on the other hand, we propose to utilize the irregular vortex shedding regime and show where the probe needs to be placed with respect to the cylinder in order to obtain unambiguous calibration data.

  7. The N domain of somatic angiotensin-converting enzyme negatively regulates ectodomain shedding and catalytic activity

    OpenAIRE

    Woodman, Zenda L.; Schwager, Sylva L. U.; Redelinghuys, Pierre; Carmona, Adriana K.; Ehlers, Mario R. W.; Sturrock, Edward D.

    2005-01-01

    sACE (somatic angiotensin-converting enzyme) consists of two homologous, N and C domains, whereas the testis isoenzyme [tACE (testis ACE)] consists of a single C domain. Both isoenzymes are shed from the cell surface by a sheddase activity, although sACE is shed much less efficiently than tACE. We hypothesize that the N domain of sACE plays a regulatory role, by occluding a recognition motif on the C domain required for ectodomain shedding and by influencing the catalytic efficiency. To test ...

  8. Short communication: Passive shedding of Mycobacterium avium ssp. paratuberculosis in commercial dairy goats in Brazil.

    Science.gov (United States)

    Schwarz, D G G; Lima, M C; Barros, M; Valente, F L; Scatamburlo, T M; Rosado, N; Oliveira, C T S A M; Oliveira, L L; Moreira, M A S

    2017-10-01

    Goat farming is a low-cost alternative to dairy production in developing countries. In Brazil, goat production has increased in recent years due in part to the implementation of programs encouraging this activity. Mycobacterium avium ssp. paratuberculosis (MAP) is the causative agent of paratuberculosis, a disease that causes chronic granulomatous enteritis in ruminants, but MAP transmission dynamics are still poorly understood in goats. In a previously published study of our research group, 10 dairy goat farms (467 animals) from Minas Gerais state were analyzed for MAP detection; 2 fecal cultures and 11 milk samples tested positive for MAP by conventional PCR and were confirmed by sequencing. Because no clinical signs were observed over 1 yr of monitoring, we hypothesized that these MAP-positive goats could be passive shedders. Thus, in the present study, 4 positive goats (4/13) from the previous study were purchased and feces and milk samples were collected for evaluation (twice, with an interval of 3 mo between tests) by culture of MAP, IS900 PCR, or both. All analyses were negative for MAP. At the last time point, blood samples were collected for ELISA, the animals were killed, and tissues collected for tissue culture and histopathology. At necropsy, no macroscopic lesions related to paratuberculosis were observed. Similarly, no histological changes were observed and MAP in samples stained by Ziehl-Neelsen was not detected. These animals were characterized as potential passive shedders with upward contamination of the teat canal by MAP. This is the first report of the passive shedding phenomenon in goats in Brazil and it highlights the importance of identifying these animals for control programs and to ensure the quality of dairy products. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  9. Internal magnesium, 2,3-diphosphoglycerate, and the regulation of the steady-state volume of human red blood cells by the Na/K/2Cl cotransport system

    Science.gov (United States)

    1992-01-01

    This study is concerned with the relationship between the Na/K/Cl cotransport sys