WorldWideScience

Sample records for sewerage line samples

  1. Sewerage system (cloaca in Roman law

    Directory of Open Access Journals (Sweden)

    Aličić Samir

    2012-01-01

    Full Text Available Sewerage system (cloaca, which implies any cavity through which waste water flows, has in Roman law a special legal protection due to its importance for public health preservation and safety of citizens. In Praetorian Edict, two interdicts are envisaged; one prohibitory, by which private sewerage system is protected and one restitutory, by which public sewerage system is protected. It is possible that a restitutory interdict about private sewerage system existed. By the public sewerage interdict, a person who blocks or damages public sewerage is ordered to restore everything to previous state. By the private sewerage interdict, anyone is forbidden to obstruct a person who wants to repair sewerage that leads from his building through neighboring buildings. By lawyers' interpretations, the application of this interdict is expanded to all realty, as well as a situation of building a new sewerage system. Moreover, it is envisaged by Praetorian edict that against a person who builds or repairs sewerage neither interdict uti possidetis can be filed. Similarly, by lawyers' interpretations, application of operis novi nuntiatio is prevented against a person who repairs or cleans sewerage system if interruption of work could cause danger. Law developed in the direction that enabled unobstructed maintenance and building of sewerage system through neighboring realty, especially if danger of effusion existed. The only limitations were comprised in the obligation of compensation of damages to third parties, and in certain obligations of public law character: obligation to obtain consent of magistrate when building a new sewerage and duty to pay sewerage tax (cloacarium.

  2. Frequency of HEV contamination in sewerage waters in Pakistan.

    Science.gov (United States)

    Ahmad, Tahir; Waheed, Yasir; Tahir, Sadia; Safi, Sher Zaman; Fatima, Kaneez; Afzal, Muhammad Sohail; Farooqi, Zia-ur-Rehman; Qadri, Ishtiaq

    2010-12-23

    Enteric viruses, including Hepatitis E virus (HEV), are able to persist under environmental conditions and may cause public health problems by contaminating natural and drinking water resources. Routine procedures for monitoring viruses in water samples have not been established for the water microbiology screening panel. Eighty-six raw sewerage samples were collected from the different regions of Islamabad and Rawalpindi, the twin cities of Pakistan. Samples were concentrated for HEV, using a polyethylene glycol-based method followed by viral RNA extraction using a commercial kit-based method. Reverse transcription polymerase chain reaction (RT-PCR) with HEV specific primers was used for the detection of HEV. The present investigation focused on 86 raw sewerage water samples taken from different locations of drainage outlets of Islamabad and Rawalpindi. After careful experimentation, 35 samples were found to be RT-PCR positive.  Nineteen (44.7%) out of 47 samples from Rawalpindi city were HEV positive while 16 (41.02%) out of 39 samples from Islamabad were HEV positive. All positive samples were found in the highly congested areas. The high detection rate of HEV in this study shows that HEV circulates at a relatively high frequency in the sewerage waters in Pakistan. This study is the first report on detection of HEV from sewerage waste water from Pakistan and suggests that HEV might be a potent indicator of viral pollution in environmental specimens.

  3. Sewerage system (cloaca) in Roman law

    OpenAIRE

    Aličić, Samir

    2012-01-01

    Sewerage system (cloaca), which implies any cavity through which waste water flows, has in Roman law a special legal protection due to its importance for public health preservation and safety of citizens. In Praetorian Edict, two interdicts are envisaged; one prohibitory, by which private sewerage system is protected and one restitutory, by which public sewerage system is protected. It is possible that a restitutory interdict about private sewerage system existed. By the public sewerage inter...

  4. Coliform bacteria as in indicator of sewerage water mixing with drinking water sources in Rawalpindi city

    International Nuclear Information System (INIS)

    Mashiatullah, A.; Qureshi, R.M.; Bibi, S.; Javed, T.; Shah, Z.; Sajjad, M.I.

    1993-12-01

    The coliform group of bacteria are consider to be one of the prominent indicators of surface/groundwater pollution as their presence in drinking water sources shows that water has been in contact with soil, plants, septic tanks or sewerage lines/drains. As a part of surface/groundwater pollution studies in various areas of Rawalpindi city coliform bacteria have been determined in the available drinking sources to evaluate their possible connection with the nearby septic tanks and sewerage lines/drains. Selective water samples were tapped from 72 domestic dug wells, and 98 municipal corporation tube-wells and associated water supply lines in some poorly drained areas of Rawalpindi. These samples were analyzed using membrane filter technique. In general, the sampled areas have indicated poor water quality w.r.t. coliform activity. 52% samples of the collected samples have indicated presence of Ecoli. Of these, 73% samples mostly collected from the poorly drained areas have shown significant counts of Ecoli. These water are rendered unfit for drinking purposes. Thirteen water samples collected indicated toxic levels of Ecoli in the municipal water supply caused due to a known leakage in the main domestic water supply line. The presence of coliform in the tube-well water supply taps are thus attributed to ruptures in the underground water supply lines. Present study reveals that general sanitary condition and water quality in the city are poor and that there is an urgent need of improvement in the water treatment and distribution systems by the concern quaters. (Orig./A.B.)

  5. Automation model of sewerage rehabilitation planning.

    Science.gov (United States)

    Yang, M D; Su, T C

    2006-01-01

    The major steps of sewerage rehabilitation include inspection of sewerage, assessment of structural conditions, computation of structural condition grades, and determination of rehabilitation methods and materials. Conventionally, sewerage rehabilitation planning relies on experts with professional background that is tedious and time-consuming. This paper proposes an automation model of planning optimal sewerage rehabilitation strategies for the sewer system by integrating image process, clustering technology, optimization, and visualization display. Firstly, image processing techniques, such as wavelet transformation and co-occurrence features extraction, were employed to extract various characteristics of structural failures from CCTV inspection images. Secondly, a classification neural network was established to automatically interpret the structural conditions by comparing the extracted features with the typical failures in a databank. Then, to achieve optimal rehabilitation efficiency, a genetic algorithm was used to determine appropriate rehabilitation methods and substitution materials for the pipe sections with a risk of mal-function and even collapse. Finally, the result from the automation model can be visualized in a geographic information system in which essential information of the sewer system and sewerage rehabilitation plans are graphically displayed. For demonstration, the automation model of optimal sewerage rehabilitation planning was applied to a sewer system in east Taichung, Chinese Taiwan.

  6. Synchronous municipal sewerage-sludge stabilization.

    Science.gov (United States)

    Bukuru, Godefroid; Jian, Yang

    2005-01-01

    A study on a pilot plant accomplishing synchronous municipal sewerage-sludge stabilization was conducted at a municipal sewerage treatment plant. Stabilization of sewerage and sludge is achieved in three-step process: anaerobic reactor, roughing filter and a microbial-earthworm-ecofilter. The integrated ecofilter utilizes an artificial ecosystem to degrade and stabilize the sewerage and sludge. When the hydraulic retention time(HRT) of the anaerobic reactor is 6 h, the hydraulic load(HL) of the bio-filter is 16 m3/(m2 x d), the HL of the eco-filter is 5 m3/(m2 x d), the recycle ratio of nitrified liquor is 1.5, the removal efficiency is 83%-89% for COD(Cr), 94%-96% for BOD5, 96%-98% for SS, and 76%-95% for NH3-N. The whole system realizes the zero emission of sludge, and has the characteristics of saving energy consumption and operational costs.

  7. Sewerage: a return to basics to benefit the poor

    OpenAIRE

    Mara, D.D.; Broome, J.

    2008-01-01

    Around 2.8 billion people, mostly in developing countries,\\ud currently lack adequate sanitation. Approximately half live\\ud in urban areas, where the most appropriate sanitation\\ud solution is commonly simplified sewerage. This paper\\ud presents the rigorous hydraulic design basis of simplified\\ud sewerage and compares this design approach with that\\ud used in the UK for conventional sewerage. It reviews\\ud simplified sewerage construction and how this achieves\\ud major cost savings and also...

  8. 25 CFR 91.13 - Health, sanitation, and sewerage disposal.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Health, sanitation, and sewerage disposal. 91.13 Section... INDIAN VILLAGES, OSAGE RESERVATION, OKLAHOMA § 91.13 Health, sanitation, and sewerage disposal. Health, sanitation, and sewerage disposal problems within the village reserves shall be subject to and controlled by...

  9. Sewerage Collection Lines, Wilkinson County and its municipalities: Data set is maintained by the MGRC with collaboration with Wilkinson County., Published in 2009, 1:4800 (1in=400ft) scale, Middle Georgia Regional Commission.

    Data.gov (United States)

    NSGIC Regional | GIS Inventory — Sewerage Collection Lines dataset current as of 2009. Wilkinson County and its municipalities: Data set is maintained by the MGRC with collaboration with Wilkinson...

  10. 10 CFR 20.2003 - Disposal by release into sanitary sewerage.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Disposal by release into sanitary sewerage. 20.2003... Disposal § 20.2003 Disposal by release into sanitary sewerage. (a) A licensee may discharge licensed material into sanitary sewerage if each of the following conditions is satisfied: (1) The material is...

  11. The proposal of recommendations for the operation of vacuum sewerage

    Science.gov (United States)

    Mazák, J.; Dvorský, T.; Václavík, V.; Zajac, R.; Hluštík, P.

    2017-10-01

    This article deals with a comparison of vacuum sewerage system and gravity based sewerage system. It also includes the results of the comparison of both of these systems from various cities, and there are measures suggested on the basis of the findings focused on increasing the efficiency and reducing the operational costs of the selected vacuum sewerage system.

  12. Ternary Blends of High Aluminate Cement, Fly ash and Blast-furnace slag for Sewerage Lining Mortar

    Science.gov (United States)

    Chao, L. C.; Kuo, C. P.

    2018-01-01

    High aluminate cement (HAC), fly ash (FA) and blast-furnace slag (BFS) have been treated sustainable materials for the use of cement products for wastewater infrastructure due to their capabilities of corrosion resistance. The purpose of this study is to optimize a ternary blend of above mentioned materials for a special type of mortar for sewerage lining. By the using of Taguchi method, four control parameters including water/cementitious material ratio, mix water content, fly ash content and blast-furnace slag content were considered in nine trial mix designs in this study. By evaluating target properties including (1) maximization of compressive strength, (2) maximization of electricity resistance and (3) minimization of water absorption rate, the best possible levels for each control parameter were determined and the optimal mix proportions were verified. Through the implementation of the study, a practical and completed idea for designing corrosion resistive mortar comprising HAC, FA and BSF is provided.

  13. Benchmarking the efficiency of the Chilean water and sewerage companies: a double-bootstrap approach.

    Science.gov (United States)

    Molinos-Senante, María; Donoso, Guillermo; Sala-Garrido, Ramon; Villegas, Andrés

    2018-03-01

    Benchmarking the efficiency of water companies is essential to set water tariffs and to promote their sustainability. In doing so, most of the previous studies have applied conventional data envelopment analysis (DEA) models. However, it is a deterministic method that does not allow to identify environmental factors influencing efficiency scores. To overcome this limitation, this paper evaluates the efficiency of a sample of Chilean water and sewerage companies applying a double-bootstrap DEA model. Results evidenced that the ranking of water and sewerage companies changes notably whether efficiency scores are computed applying conventional or double-bootstrap DEA models. Moreover, it was found that the percentage of non-revenue water and customer density are factors influencing the efficiency of Chilean water and sewerage companies. This paper illustrates the importance of using a robust and reliable method to increase the relevance of benchmarking tools.

  14. ANALYSIS OF GROUP MAINTENANCE STRATEGY -ROAD PAVEMENT AND SEWERAGE PIPES-

    Science.gov (United States)

    Tanimoto, Keishi; Sugimoto, Yasuaki; Miyamoto, Shinya; Nada, Hideki; Hosoi, Yoshihiko

    Recently, it is critical to manage deteriorating sewerage and road facilities efficiently and strategically. Since the sewerage pipes are mostly installed under road pavement, the works for the replacement of the sewerage pipes are partially common to the works for the road. This means that the replacement cost can be saved by coordinating the timing of the replacements by sewerage pipe and road pavement. The purpose of the study is to develop the model based on Markov decision process to derive the optimal group maintenance policy so as to minimize lifecycle cost. Then the model is applied to case study area and demonstrated to estimate the lifecycle cost using statistical data such as pipe replacement cost, road pavement rehabilitation cost, and state of deterioration of pipes and road pavement.

  15. Contamination level in vegetables grown around Peshawar using sewerage and canal water

    International Nuclear Information System (INIS)

    Mahmood, S.

    2001-01-01

    The level of contamination in vegetables grown around Peshawar using sewerage/canal water is reported. The vegetable samples were collected from three representative locations. The results indicated that vegetables grown with sewerage water contained higher levels of Cd, Cu and Pb than those with irrigation water. Maximum amount of Cd was in Qulfa (3.68 mu g/ g) followed by sponge gourd leaves (3.38 mu g/ g) the tomato leaves (93.32 mu g/ g). while Pb in tomato leaves (4.88 mu g / g), Cu content ranged between 2.08 and 7.5 mu g/g in these vegetables. In the vegetables grown with canal water the Cd ranged 0.82 - 2.88 mu g/g, Cu 2.38 mu g /g and Pb 0.84 - 1.88 mu g/ g. The concentration of Fe and P in the vegetables of sewerage water ranged 9.0-25.0 and 5.6-14.8 mg/100g respectively while those grown with canal water 9.0-11.0 mg/ 100 g and 8.4-12.8 mg/ 100 g respectively. (author)

  16. Current research trend on urban sewerage system in China

    Science.gov (United States)

    Ning, Yun-Fang; Dong, Wen-Yi; Lin, Lu-Sheng; Zhang, Qian

    2017-03-01

    The research emphasis has always been on sewerage treatment technology in China, though urban drainage system has gained little attention. In the context of urban drainage system and the problem associated with rain, the focus is still mainly toward the simple “emissions”. While the relationship between conservation and utilization of rainwater resources and urban ecology are popular, the relationship between rainwater discharge and non-point source pollution are often neglected. The reasonable choice of sewerage system is dependent on the collection and discharge of urban sewerage, the applicability and economic benefits, along with the ability to meet the water quality requirements and environmental protection. This paper analyzes and summarizes the development of urban drainage system in china, and introduces different drainage forms. The choice of drainage system should be based on the overall planning of the city, environmental protection requirements, the local natural conditions and water conditions, urban sewerage and water quality, the original drainage facilities, and local climatic conditions. It must be comprehensive to meet the environmental protection requirements, through technical and economic comparison.

  17. Needs-based sewerage prioritization: alternative to conventional cost-benefit analysis.

    Science.gov (United States)

    Rashid, Md M; Hayes, Donald F

    2011-10-01

    This paper presents an empirical approach to select and prioritize sewerage projects within set budgetary limitations. The methodology includes a model which quantifies benefits of a sewerage project as an index or dimensionless number. The index considers need and urgency of sewerage and other project goals. Benefit is defined as the difference in anticipated impact between the current condition (without the project) and the expected condition with the project. Anticipated benefits primarily include reduction in environmental pollution, reduction of human diseases and morbidity, and other tangible and intangible improvement. This approach is a powerful decision tool for sewerage prioritization and an effective alternative to conventional cost-benefit analysis. Unlike conventional analysis, this approach makes no attempt to convert project benefits and other impacts into a monetary measure. This work recognizes that the decision to provide sewerage based solely on net benefits is not practical. Instead, benefit-cost ratios (B/C) are calculated utilizing cost-effectiveness approach. Using these ratios, 16 unserviced areas of Ensenada, Mexico are ranked. The prioritization rankings produced by this method must be further scrutinized and carefully reviewed for logic, accuracy of input data, and practicality of implementation. A similar framework may also be useful for prioritizing other public works projects. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Impediments to the adoption of alternative sewerage in South African urban informal settlements.

    Science.gov (United States)

    Ashipala, N; Armitage, N P

    2011-01-01

    In recent decades South Africa has witnessed a substantial growth in its urban population. This growth has been accompanied by the mushrooming of informal settlements (shantytowns) flanking more formal development. The lack of adequate urban drainage in many of these informal settlements has resulted in extremely polluted environments which add to the disease burden of the poor people who live there. In many instances, informal settlements in South Africa are established on marginal land that is inherently difficult to service using conventional gravity sewerage. International experience has shown that various alternative wastewater collection systems may present more appropriate ways of providing water-borne sewerage in areas that are difficult to service by conventional means. Alternative sewerage schemes have however had a poor record of success in South African informal settlements - primarily stemming from the implementing agencies' failure to adequately address various social and institutional factors. In this paper, a review of South African experiences with simplified sewerage, settled sewerage and vacuum sewerage in urban informal settlements is used to highlight the key constraints that currently impede the application of these technologies.

  19. Sewerage Pumping Stations, File name = UTILITIES - PARTIAL Data is incomplete. Contains electric trans lines, electric substations, sewer plants, sewer pumpstations, water plants, water tanks http://www.harfordcountymd.gov/gis/Index.cfm, Published in 2011, 1:600 (1in=50ft) scale, Harford County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Sewerage Pumping Stations dataset current as of 2011. File name = UTILITIES - PARTIAL Data is incomplete. Contains electric trans lines, electric substations, sewer...

  20. Determination of an Optimal Trunk Sewer-line Route for Kikuyu ...

    African Journals Online (AJOL)

    The best alternative is a sewerage system that uses sewer-lines to convey sewage into a treatment works. This project seeks to replace the traditional methods currently used in Kikuyu Town with a sewerage system. Geospatial technologies are used to site a treatment plant and the main trunk sewer-line route in Kikuyu ...

  1. Heavy metal contents and other physical quality indices of sewerage, canal and drinking water

    International Nuclear Information System (INIS)

    Mahmood, S.; Sattar, A.; Ihsanullash; Atta, S.; Arif, S. University of Engineering and Technology, Peshawar

    2001-01-01

    Analysis of Cd, Pb and Cu in canal, sewerage and drinking water by potentiometric stripping analysis (PSA) is described. Other quality indices of water such as temperature, pH, EC and total solid were also determined. The levels of heavy metal contents of sewerage, canal and drinking water revealed marked differences and wide coefficient of variability (CV). Generally Cd and Pb contents were higher in sewerage than canal and drinking water. However, Cu content of drinking waters was higher than other water tested. The total solids were found to be generally higher in sewerage and canal water than drinking water tested. The total solids were found to be generally higher in sewerage and canal water than drinking water The variations in temperature, pH and EC were marginal to marked depending upon the source and the location. (author)

  2. Measurement of the gross α radioactivity in a river near a sewerage of a uranium mine

    International Nuclear Information System (INIS)

    Xu Congxue; Li Tianduo; Zhou Chunlin; Han Feng; Ma Wenyan

    2003-01-01

    This paper introduced the measurement of the gross α radioactivity in a river near a sewerage of a uranium mine. By using the drip infusion set, the water was transfused into the sample trays and evaporated directly. This method makes it possible batch the water samples

  3. Auto-control of pumping operations in sewerage systems by rule-based fuzzy neural networks

    Directory of Open Access Journals (Sweden)

    Y.-M. Chiang

    2011-01-01

    Full Text Available Pumping stations play an important role in flood mitigation in metropolitan areas. The existing sewerage systems, however, are facing a great challenge of fast rising peak flow resulting from urbanization and climate change. It is imperative to construct an efficient and accurate operating prediction model for pumping stations to simulate the drainage mechanism for discharging the rainwater in advance. In this study, we propose two rule-based fuzzy neural networks, adaptive neuro-fuzzy inference system (ANFIS and counterpropagation fuzzy neural network for on-line predicting of the number of open and closed pumps of a pivotal pumping station in Taipei city up to a lead time of 20 min. The performance of ANFIS outperforms that of CFNN in terms of model efficiency, accuracy, and correctness. Furthermore, the results not only show the predictive water levels do contribute to the successfully operating pumping stations but also demonstrate the applicability and reliability of ANFIS in automatically controlling the urban sewerage systems.

  4. Acceptability of sewerage outfalls in accordance with the new water laws

    Energy Technology Data Exchange (ETDEWEB)

    Czychowski, M

    1980-01-01

    In more than one respect, sewerage outfalls must be seen in a different light since the fourth amendment to the water resources policy act was passed on April 24th 1976, which incorporated the sewerage taxation law of September 13th 1976 and its administrative by-laws. A review on the situation to date is given.

  5. Using sewerage system to generate electricity

    International Nuclear Information System (INIS)

    Asghar, J.

    2005-01-01

    The development of the sanitary engineering has paralleled and contributed to the growth of the city. Without an adequate supply of safe water, the great city could not exist and life in it would be both unpleasant and dangerous unless human and other waste were promptly removed. The concentration of population in relatively small areas has made the task of sanitary engineer more complex. The cities, towns and villages are being polluted ground water and surface water. Industries also demand more and better water from all available sources. The rivers receive ever-increasing amount of sewage and industrial wastes and thus resulting more attention to the water treatment, stream pollution and complicated phenomena of self-purification. In many developing countries there is no such treatment plants for the sewerage water. Rivers receive large amount of polluted water and resulting many diseases. Thus self-purification and treatment plants playa vital role in sanitation. The other benefit is now introducing as Generating electricity from Sewerage System. (author)

  6. Renovation of the Stockholm sewerage system

    International Nuclear Information System (INIS)

    Sandin, Paer

    1987-01-01

    Within a few years Stockholm will let all its treated wastewater into the Saltsjoen. The Saltsjoen is the inner part of the Stockholm Archipelago, which is one of the finest recreation areas in Sweden and where many Stockholmians spend a great deal of their leisure time. That is one reason why it is so important that all wastewater is treated before it reaches the recipient. A sewerage system in bad condition means that the risk of not allowed/unplanned overflows is increased. In order to prevent overflows we drafted 'Plan 83' which tells us how our sewerage system shall be constructed in the future and what measures has to be made in the system. Renovations of the existing pipes is one method to get a well functioning sewer system. Today we have made about 50 different objects at a total length of 6000 m. Why do we renovate sewers and why are we attempting to develop methods for pipe renovations?

  7. Effects of sewerage on diarrhoea and enteric infections: a systematic review and meta-analysis.

    Science.gov (United States)

    Norman, Guy; Pedley, Steve; Takkouche, Bahi

    2010-08-01

    Sanitation is inadequate in most cities in developing countries, with major effects on infectious disease burden: in this situation, is piped sewerage an appropriate solution, or should efforts focus on systems based on onsite solutions, such as latrines? We reviewed the effects of the presence of sewerage systems on diarrhoeal disease and related outcomes. We included only observational studies because so far there have been no randomised controlled trials. We identified relevant studies by use of a comprehensive strategy including searches of Medline and other databases from 1966 to February, 2010. In studies that compared sewerage with one other sanitation category, we used relative risk (RR) estimates for sewerage versus the other category. When a single study made two or more comparisons, we calculated a weighted average RR value, and used this value in our meta-analysis. We used the most adjusted RR estimate provided by the authors; if no adjusted estimate was available, we used the crude estimate. To obtain pooled-effect estimates, meta-analyses were done by use of an inverse variance method-ie, the study-specific adjusted log ORs for case-control and cross-sectional studies, and log RRs for cohort studies, were weighted by the inverse of their variance to compute a pooled RR with 95% CI. 25 studies investigated the association between sewerage and diarrhoea or related outcomes, including presence of intestinal nematodes. Pooled estimates show that sewerage systems typically reduce diarrhoea incidence by about 30% (RR 0.70, 95% CI 0.61-0.79), or perhaps as much as 60% when starting sanitation conditions are very poor. Studies with objective outcome measures showed even stronger pooled effect than studies that assessed diarrhoea incidence with interviews, while sensitivity analysis indicated that the effect remains even if we assume strong residual confounding. Sewerage interventions seem to reduce the incidence of diarrhoea and related outcomes. However, we

  8. Sewerage Mapping and Information System of the Metropolis of Tokyo (SEMIS) : Details of the Development and Outline of the System

    Science.gov (United States)

    Kawakami, Kouichi; Sekita, Mitsunobu

    It is essential to manage sewerage ledgers as information when maintaining and controlling sewerage, one of the infrastructures of cities. The Bureau of Sewerage developed the full scale Sewerage Mapping and Information System (SEMIS), the first trial done by a local government in this country and has operated it since 1985. Before the development the questionnaires were conducted to survey the use of sewerage ledgers by staffs engaged in sewage works, and means of improving how to prepare plans of sewerage were considered based on them. Employing these means the Bureau made a database of plans and descriptions which comprise sewerage ledgers, and then constructed the computer system which manages it comprehensively. The details of the development and the system outline are described.

  9. BENEFITS OF SEWERAGE SYSTEM REAL-TIME CONTROL

    Science.gov (United States)

    Real-time control (RTC) is a custom-designed computer-assisted management system for a specific urban sewerage network that is activated during a wet-weather flow event. Though uses of RTC systems had started in the mid 60s, recent developments in computers, telecommunication, in...

  10. The essential aspect in sewerage regulation in Indonesia

    Science.gov (United States)

    Siami, L.

    2018-01-01

    Several cities in Indonesia have the sewerage local regulation such as Banjarmasin, Bantul, Surakarta and Denpasar. Meanwhile, The National Government have guideline in composing domestic sewerage regulation. Each city have their own characteristic and issues that need to be carried out by the local regulation. By using SWOT analysis, this study tries to figure out several aspect that need to be included in the local regulation. International references from developed and developing countries like Japan, Phillipines, Malaysia and Thailand were also used as benchmark without neglecting the local conditions of cities in Indonesia. Several crucial aspect of local regulation are institutional authority, composition on-site and off-site system, tariff, evaluation and monitoring, as well as punishment and rewards. Both tariff and evaluation aspects need to be narrowed down into specific regulations.

  11. The impact of an urban sewerage system on childhood diarrhoea in Tehran, Iran: a concurrent control field trial.

    Science.gov (United States)

    Kolahi, Ali-Asghar; Rastegarpour, Ali; Sohrabi, Mohammad-Reza

    2009-05-01

    The stepwise implementation of the Tehran Sewerage Project provided a convenient setting for which health impacts of an urban sewerage system could be examined with appropriate controls. In 2001, Tehran municipal districts 17 and 18 had no sewerage system connections, but areas within these districts had been planned to be connected by 2006. These areas were chosen as an intervention group. Neighbouring areas, with a similar socio-economic status, that had not been planned to connect to the sewerage system by 2006, were chosen as controls. Homes within designated areas were randomized and surveyed twice to determine diarrhoea incidences for children aged 6-60 months, once in 2001, before connection to the sewerage system, and once again in 2006, after the intervention. By 2006, 76% of the homes in the intervention zones were connected to the sewerage system. In the first stage of the study, diarrhoea incidences for intervention and control groups were 18.6 and 16.6%, respectively. In the second stage, incidences decreased to 10.1 and 10.5%, respectively. Data collected from 4179 children demonstrated that the diarrhoea incidence had decreased by 46% in the intervention group, whereas it had decreased by 37% in the controls.

  12. Microbial Character Related Sulfur Cycle under Dynamic Environmental Factors Based on the Microbial Population Analysis in Sewerage System.

    Science.gov (United States)

    Dong, Qian; Shi, Hanchang; Liu, Yanchen

    2017-01-01

    The undesired sulfur cycle derived by microbial population can ultimately causes the serious problems of sewerage systems. However, the microbial community characters under dynamic environment factors in actual sewerage system is still not enough. This current study aimed to character the distributions and compositions of microbial communities that participate in the sulfur cycle under the dynamic environmental conditions in a local sewerage system. To accomplish this, microbial community compositions were assessed using 454 high-throughput sequencing (16S rDNA) combined with dsrB gene-based denaturing gradient gel electrophoresis. The results indicated that a higher diversity of microbial species was present at locations in sewers with high concentrations of H 2 S. Actinobacteria and Proteobacteria were dominant in the sewerage system, while Actinobacteria alone were dominant in regions with high concentrations of H 2 S. Specifically, the unique operational taxonomic units could aid to characterize the distinct microbial communities within a sewerage manhole. The proportion of sulfate-reducing bacteria, each sulfur-oxidizing bacteria (SOB) were strongly correlated with the liquid parameters (DO, ORP, COD, Sulfide, NH 3 -N), while the Mycobacterium and Acidophilic SOB (M&A) was strongly correlated with gaseous factors within the sewer, such as H 2 S, CH 4 , and CO. Identifying the distributions and proportions of critical microbial communities within sewerage systems could provide insights into how the microbial sulfur cycle is affected by the dynamic environmental conditions that exist in sewers and might be useful for explaining the potential sewerage problems.

  13. 3-D steady analysis of flow in CRDM sewerage system

    International Nuclear Information System (INIS)

    Sun Yan; Liang Tiebo; Chen Zhihui; Zhao Jing; Zhang Yulong

    2014-01-01

    In order to obtain the flow state during sewer condition in Reactor and CRDM Sewerage system (RSE), this paper analyzes the 3-D steady flow in RSE by using Computational Fluid Dynamics (CFD) method. In the premise that the pressure drop of the RSE is known, the mass flow rate, the velocity and the type of flow in the system is obtained with the inverse method, which is proposed and validated to be applicable in the paper. The result shows that in the sewerage conditions, the type of flow in the RSE is turbulence flow, which is helpful to sewer drain. The study results give an reference for the design of RSE. (authors)

  14. Trajectory of Sewerage System Development Optimization

    Science.gov (United States)

    Chupin, R. V.; Mayzel, I. V.; Chupin, V. R.

    2017-11-01

    The transition to market relations has determined a new technology for our country to manage the development of urban engineering systems. This technology has shifted to the municipal level and it can, in large, be presented in two stages. The first is the development of a scheme for the development of the water supply and sanitation system, the second is the implementation of this scheme on the basis of investment programs of utilities. In the investment programs, financial support is provided for the development and reconstruction of water disposal systems due to the investment component in the tariff, connection fees for newly commissioned capital construction projects and targeted financing for selected state and municipal programs, loans and credits. Financial provision with the development of sewerage systems becomes limited and the problem arises in their rational distribution between the construction of new water disposal facilities and the reconstruction of existing ones. The paper suggests a methodology for developing options for the development of sewerage systems, selecting the best of them by the life cycle cost criterion, taking into account the limited investments in their construction, models and methods of analysis, optimizing their reconstruction and development, taking into account reliability and seismic resistance.

  15. Impact of drainage and sewerage on diarrhoea in poor urban areas in Salvador, Brazil.

    Science.gov (United States)

    Moraes, L R; Cancio, Jacira Azevedo; Cairncross, Sandy; Huttly, Sharon

    2003-01-01

    A longitudinal prospective study of the effect of drainage and sewerage systems on diarrhoea in children aged sewerage improvements, and 3 from neither. An extensive questionnaire was applied to collect information on each child and on the conditions of the household, and mothers recorded diarrhoea episodes in their children aged sewerage less than one-third, of the incidence in neighbourhoods with neither. After controlling for potential confounders, the proportion of children with 'frequent diarrhoea' showed the same significant trend across the study groups. Though the groups were not exactly comparable, more than one child was monitored per household, and it was not possible to rotate fieldworkers between study groups, the study provides evidence that community sanitation can have an impact on diarrhoeal disease, even without measures to promote hygiene behaviour.

  16. Including public perception data in the evaluation of the consequences of sewerage derived urban flooding.

    Science.gov (United States)

    Arthur, Scott; Crow, Helen; Karikas, Naoum

    2009-01-01

    This text reports research which was undertaken to assess the failure consequences associated with sewerage systems. In an effort to move away from considering only flood volume, depth or extent, the text will focus on how a survey of public opinion was used to inform the development of a consequence scoring methodology. The failure consequences considered range from internal flooding of properties, to road closure, environmental damage and odour problems. The text reports the extent to which experience of flooding influences perceptions of failure consequence and sewerage system management. It is also outlined how this data was used, along with other data sources, to construct an objective scoring process that can be used to evaluate failure consequence and readily prioritise sewerage maintenance.

  17. The Financing of Water Supply and Sewerage Services in Romania

    Directory of Open Access Journals (Sweden)

    Alina Florentina CUCOS

    2013-08-01

    Full Text Available Water supply and sewerage services represent utilities that must be provided to all users, both the urban and the rural. The responsibility to ensure these services in terms of non-discrimination and affordability belongs to the local authorities, which in the spirit of decentralization have exclusive jurisdiction on their establishment, organization and operation. Regardless of the chosen management, the funding of water supply and sewerage services, is accomplished by means of the prices and tariffs paid by the users. Their quantum, specific to some social services, covers the costs without allowing the accumulation of consistent profit margins, which would ensure the development of the specific infrastructure from the operators' own funds. It is therefore necessary that funding for the creation and rehabilitation of water supply and sewerage systems to be provided from other sources than the budgets of operators, such as: budgetary allocations of local public authorities, government or European funding programs. This paper is of interest because it captures just how the prices and tariffs for these services are composed, and the entire procedure for foundation, adjustment and modification that follows different rules from those of pricing in the market economy, and it provides a review of the types of programs through which the development of the specific technical-urban infrastructure and the significant increase in the number of users in the past 25 years.

  18. Sewerage force adjustment technology for energy conservation in vacuum sanitation systems

    Science.gov (United States)

    Guo, Zhonghua; Li, Xiaoning; Kagawa, Toshiharu

    2013-03-01

    The vacuum sanitation is the safe and sound disposal approach of human excreta under the specific environments like flights, high speed trains and submarines. However, the propulsive force of current systems is not adjustable and the energy consumption does not adapt to the real time sewerage requirement. Therefore, it is important to study the sewerage force adjustment to improve the energy efficiency. This paper proposes an energy conservation design in vacuum sanitation systems with pneumatic ejector circuits. The sewerage force is controlled by changing the systematic vacuum degree according to the amount of the excreta. In particular, the amount of the excreta is tested by liquid level sensor and mass sensor. According to the amount of the excreta, the relationship between the excreta amount and the sewerage force is studied to provide proper propulsive force. In the other aspect, to provide variable vacuum degrees for different sanitation requirements, the suction and discharge system is designed with pneumatic vacuum ejector. On the basis of the static flow-rate characteristics and the vacuum generation model, the pressure response in the ejector circuit is studied by using the static flow rate characteristics of the ejector and air status equation. The relationship is obtained between supplied compressed air and systematic vacuum degree. When the compressed air is supplied to the ejector continuously, the systematic vacuum degree increases until the vacuum degree reaches the extreme value. Therefore, the variable systematic vacuum degree is obtained by controlling the compressed air supply of the ejector. To verify the effect of energy conservation, experiments are carried out in the artificial excreta collection, and the variable vacuum-degree design saves more than 30% of the energy supply. The energy conservation is realized effectively in the new vacuum sanitation systems with good application prospect. The proposed technology provides technological

  19. Assessment on inflow and infiltration in sewerage systems of Kuantan, Pahang.

    Science.gov (United States)

    Yap, Hiew Thong; Ngien, Su Kong

    2017-12-01

    Inflow and infiltration are important aspects of sewerage systems that need to be considered during the design stage and constantly monitored once the sewerage system is in operation. The aim of this research is to analyse the relationship of rainfall as well as inflow infiltration with sewage flow patterns through data collected from fieldwork. Three sewer pipelines were selected at the residential areas of Taman Lepar Hilir Saujana, Bandar Putra and Kota Sas for data collection. Sewage flow data were collected in terms of flowrate, velocity and depth of flow using flowmeters with ultrasonic sensors that utilize the continuous Doppler effect in the sewer pipelines, while rainfall intensity data were collected using rain gauges installed at the study locations. Based on the result, the average infiltration rates of Q peak and Q ave for the locations were 17% and 21%, which exceeded the respective values of 5% and 10% stated in Hammer and Hammer. The flowrate of wastewater in the sewer pipelines was found to be directly proportional to rainfall. These findings indicate that the sewer pipelines in the study areas may have been affected by capacity reduction, whereas the sewerage treatment plants receiving the wastewater influent may have been overloaded.

  20. Household Response to Inadequate Sewerage and Garbage Collection Services in Abuja, Nigeria.

    Science.gov (United States)

    Abubakar, Ismaila Rimi

    2017-01-01

    Provision of sanitation and garbage collection services is an important and yet challenging issue in the rapidly growing cities of developing countries, with significant human health and environmental sustainability implications. Although a growing number of studies have investigated the consequences of inadequate delivery of basic urban services in developing countries, few studies have examined how households cope with the problems. Using the Exit, Voice, Loyalty, and Neglect (EVLN) model, this article explores how households respond to inadequate sewerage and garbage collection services in Abuja, Nigeria. Based on a qualitative study, data were gathered from in-depth interviews with sixty households, complemented with personal observation. The findings from grounded analysis indicated that majority (62%) and about half (55%) of the respondents have utilized the informal sector for sewerage services and garbage collection, respectively, to supplement the services provided by the city. While 68% of the respondents reported investing their personal resources to improve the delivery of existing sewerage services, half (53%) have collectively complained to the utility agency and few (22%) have neglected the problems. The paper concludes by discussing the public health and environmental sustainability implications of the findings.

  1. Culturally appropriate organization of water and sewerage projects built through public private partnerships.

    Directory of Open Access Journals (Sweden)

    Jessica A Kaminsky

    Full Text Available This paper contributes to the pursuit of socially sustainable water and sanitation infrastructure for all people by discovering statistically robust relationships between Hofstede's dimensions of cross-cultural comparison and the choice of contract award types, project type, and primary revenue sources. This analysis, which represents 973 projects distributed across 24 low- and middle-income nations, uses a World Bank dataset describing high capital cost water and sewerage projects funded through private investment. The results show that cultural dimensions explain variation in the choice of contract award types, project type, and primary revenue sources. These results provide empirical evidence that strategies for water and sewerage project organization are not culturally neutral. The data show, for example, that highly individualistic contexts are more likely to select competitive contract award types and to depend on user fees to provide the primary project revenue stream post-construction. By selecting more locally appropriate ways to organize projects, project stakeholders will be better able to pursue the construction of socially sustainable water and sewerage infrastructure.

  2. Culturally appropriate organization of water and sewerage projects built through public private partnerships.

    Science.gov (United States)

    Kaminsky, Jessica A

    2017-01-01

    This paper contributes to the pursuit of socially sustainable water and sanitation infrastructure for all people by discovering statistically robust relationships between Hofstede's dimensions of cross-cultural comparison and the choice of contract award types, project type, and primary revenue sources. This analysis, which represents 973 projects distributed across 24 low- and middle-income nations, uses a World Bank dataset describing high capital cost water and sewerage projects funded through private investment. The results show that cultural dimensions explain variation in the choice of contract award types, project type, and primary revenue sources. These results provide empirical evidence that strategies for water and sewerage project organization are not culturally neutral. The data show, for example, that highly individualistic contexts are more likely to select competitive contract award types and to depend on user fees to provide the primary project revenue stream post-construction. By selecting more locally appropriate ways to organize projects, project stakeholders will be better able to pursue the construction of socially sustainable water and sewerage infrastructure.

  3. Fate of Zinc and Silver Engineered Nanoparticles in Sewerage Networks

    Science.gov (United States)

    Engineered zinc oxide (ZnO) and silver (Ag) nanoparticles (NPs) used in consumer products are largely released into the environment through the wastewater stream. Limited information is available regarding the transformations they undergo during their transit through sewerage sy...

  4. Impact of drainage and sewerage on intestinal nematode infections in poor urban areas in Salvador, Brazil.

    Science.gov (United States)

    Moraes, L R S; Cancio, Jacira Azevedo; Cairncross, Sandy

    2004-04-01

    This cross-sectional study was conducted in 1989 among children aged between 5 and 14 years old living in nine poor urban areas of the city of Salvador (pop. 2.44 million), capital of Bahia State, in Northeast Brazil. Three of these areas had benefited from both drainage and sewerage, 3 from improved drainage only, and 3 from neither. The children studied thus belonged to 3 exposure groups regarding their level of sanitation infrastructure. An extensive questionnaire was applied to collect information on each child and on the conditions of the household, and stool examinations of the children 5-14 years old were performed to measure nematode infection. Comparison of the sewerage group with the drainage-only group and the latter with the control (no sewerage or drainage) group showed that, when the level of community sanitation was better, the prevalence of infection among children was less, but risk factors identified for infection were more numerous and more significant. Intensity of infection with Trichuris, but not with Ascaris or hookworm, was also less. The results suggest that sewerage and drainage can have a significant effect on intestinal nematode infections, by reducing transmission occurring in the public domain.

  5. OXYGEN TRANSFER STUDIES AT THE MADISON METROPOLITAN SEWERAGE DISTRICT FACILITIES

    Science.gov (United States)

    Field studies at the Madison Metropolitan Sewerage District facilities were conducted over a 3-year period to obtain long-term data on the performance of fine pore aeration equipment in municipal wastewater. The studies were conducted on several basins in the East Plant containi...

  6. Prevention of strong stench for stocked radioisotope sewerage using total water treatment agent for small-sized cooling towers

    International Nuclear Information System (INIS)

    Aoki, Katsumi; Nishimaki, Toshiyuki; Furuse, Yuko; Shinozuka, Akiko

    1996-01-01

    In general, the sewerage at radioisotope laboratories has very strong stench. We treated the sewerage with a total water treatment agent (Tachileslegi, Nippon Nouyaku Co., Ltd. ) that is widely used for prevention of slime, scale, corrosion in cooling towers. As the result, the stench was decreased to about two thirds to that of control estimated by odor-test. (author)

  7. OPTIMIZED REAL-TIME CONTROL OF COMBINED SEWERAGE SYSTEMS: TWO CASE STUDIES

    Science.gov (United States)

    The paper presents results of two case studies of Real-Time Control (RTC) alternatives evaluations that were conducted on portions of sewerage systems near Paris, France and in Quebec City, Canada, respectively. The studies were performed at real-scale demonstration sites. RTC ...

  8. Geolocation Support for Water Supply and Sewerage Projects in Azerbaijan

    Science.gov (United States)

    Qocamanov, M. H.; Gurbanov, Ch. Z.

    2016-10-01

    Drinking water supply and sewerage system designing and reconstruction projects are being extensively conducted in Azerbaijan Republic. During implementation of such projects, collecting large amount of information about the area and detailed investigations are crucial. Joint use of the aerospace monitoring and GIS play an essential role for the studies of the impact of environmental factors, development of the analytical information systems and others, while achieving the reliable performance of the existing and designed major water supply pipelines, as well as construction and exploitation of the technical installations. With our participation the GIS has been created in "Azersu" OJSC that includes systematic database of the drinking water supply and sewerage system, and rain water networks to carry out necessary geo information analysis. GIScreated based on "Microstation" platform and aerospace data. Should be mentioned that, in the country, specifically in large cities (i.e. Baku, Ganja, Sumqait, etc.,) drinking water supply pipelines cross regions with different physico-geographical conditions, geo-morphological compositions and seismotectonics.Mains water supply lines in many accidents occur during the operation, it also creates problems with drinking water consumers. In some cases the damage is caused by large-scale accidents. Long-term experience gives reason to say that the elimination of the consequences of accidents is a major cost. Therefore, to avoid such events and to prevent their exploitation and geodetic monitoring system to improve the rules on key issues. Therefore, constant control of the plan-height positioning, geodetic measurements for the detailed examination of the dynamics, repetition of the geodetic measurements for certain time intervals, or in other words regular monitoring is very important. During geodetic monitoring using the GIS has special significance. Given that, collecting geodetic monitoring measurements of the main pipelines

  9. Prevalence of antibiotic resistant coliform bacteria, Enterococcus spp. and Staphylococcus spp. in wastewater sewerage biofilm.

    Science.gov (United States)

    Lépesová, Kristína; Kraková, Lucia; Pangallo, Domenico; Medveďová, Alžbeta; Olejníková, Petra; Mackuľak, Tomáš; Tichý, Jozef; Grabic, Roman; Birošová, Lucia

    2018-03-28

    Urban wastewater contains different micropollutants and high number of different microorganisms. Some bacteria in wastewater can attach to the surfaces and form biofilm, which gives bacteria advantage in fight against environmental stress. This work is focused on bacterial community analysis in biofilms isolated from influent and effluent sewerage of wastewater treatment plant in Bratislava. Biofilm microbiota detection was performed by culture-independent and culture-dependent approaches. Composition of bacterial strains was detected by denaturing gradient gel electrophoresis fingerprinting coupled with the construction of 16S rRNA clone libraries. The biofilm collected at the inlet point was characterized primarily by the presence of Pseudomonas sp., Acinetobacter sp. and Janthinobacterium sp. clones, while in the biofilm isolated at outflow of wastewater treatment plant members of Pseudomonas genus were largely detected. Beside this analysis prevalence of antibiotics and resistant coliforms, Enterococcus spp. and Staphylococcus spp. in sewerage was studied. In influent wastewater were dominant antibiotics like azithromycin, clarithromycin and ciprofloxacin. Removal efficiency of these antibiotics notably azithromycin and clarithromycin were 30% in most cases. The highest number of resistant bacteria with predominance of coliforms was detected in sample of effluent biofilm. Multidrug resistant strains in effluent biofilm showed very good ability to form biofilm. Copyright © 2018. Published by Elsevier Ltd.

  10. FINE PORE DIFFUSER SYSTEM EVALUATION FOR THE GREEN BAY METROPOLITAN SEWERAGE DISTRICT

    Science.gov (United States)

    The Green Bay Metropolitan Sewerage District retrofitted two quadrants of their activated sludge aeration system with ceramic and membrane fine pore diffusers to provide savings in energy usage compared to the sparged turbine aerators originally installed. Because significant di...

  11. 2009 Melbourne metropolitan sewerage strategy: a portfolio of decentralised and on-site concept designs.

    Science.gov (United States)

    Brown, V; Jackson, D W; Khalifé, M

    2010-01-01

    The bulk and retail water companies of the greater Melbourne area are developing the 2009 Metropolitan Sewerage Strategy to provide sustainable sewerage services to 2060. The objective of the strategy is to establish long term principles and near term actions to produce a robust sewage management system for Melbourne. Melbourne's existing sewerage system is largely centralised and discharges to two major treatment plants. Several small satellite treatment plants service local urban areas generally more distant from the centralised system. Decentralised and on-site wastewater systems are options for future sewage management and could play a role in local recycling. A portfolio of 18 on-site and decentralised concept designs was developed, applicable to the full range of urban development types in Melbourne. The concepts can be used in evaluation of metropolitan system configurations as part of future integrated water cycle planning. The options included secondary and tertiary treatment systems incorporating re-use of water for non potable uses, urine separation, black and greywater separation and composting toilets. On-site and cluster treatment systems were analysed. Each option is described by its indicative capital and operating costs, energy use and water and nutrient balances. This paper summarises and compares the portfolio mix of decentralized and on-site options in Melbourne's context.

  12. Sewerage overflows put production and fertility of dairy cows at risk

    NARCIS (Netherlands)

    Meijer, G.A.L.; Bree, de J.; Wagenaar, J.A.; Spoelstra, S.F.

    1999-01-01

    More than 50% of the diary farmers in the Netherlands use surface water as the main source of drinking water for their cows during the grazing season. The quality of this water may be affected by discharges from sewerage overflows, but possible effects on health of dairy cows have not been

  13. Task profile and risk of occupational hepatitis A infection in sewerage workers.

    Science.gov (United States)

    Nuebling, M; Hofmann, F

    2001-10-01

    The aim of the study was to assess to what extent parameters of task-related occupational exposure influence anti-hepatitis A virus (anti-HAV) seroprevalence in sewerage workers, using a new instrument for classification of exposure. A new instrument for the assessment of work-related infection hazards was developed based on expert interviews, evaluation of literature and theoretical considerations. It was included in a questionnaire for collecting detailed information on occupational exposure, safety awareness, safety behaviour and socio-demography. Anti-HAV status was assessed for all (n = 343) (non-vaccinated) study participants. Marked differences in task profile and task-related exposure within the group of sewerage workers were found, underlining the necessity of a detailed exposure analysis. In a multivariate model three risk factors that were related significantly to anti-HAV positivity were identified: age, country of origin and task-related exposure. Since task profiles and occupational exposure differ strongly within the job category of sewerage workers. evaluation of endangerment has to reflect individual task-related exposure. The task-exposure matrix developed and presented in this study is a practicable and valid instrument for exposure assessment and may be used for the exposure analysis of further biological agents in this working environment. Besides the known risk parameters age and origin, our study demonstrates a dose-response relationship between the degree of occupational exposure and the anti-HAV seroprevalence. Therefore, an effective worksite HAV-prevention programme should consider all technical, structural and educational measures that help to reduce individual exposure.

  14. Minimising street work disruption by mapping cavities derived from 3D GPR-data: a new sewerage project in Torrente (Valencia, Spain)

    Science.gov (United States)

    Valls, Ana; Garcia, Francisco; Ramirez, Manuel; Benlloch, Javier

    2015-04-01

    Ground penetrating radar is usually employed for non-destructive detection of cavities in karst areas and road maintenance. This paper describes the inspection for cavity detection in a street located in Torrente (Valencia, Spain) where a new sewerage project was planned. Torrente population growth (more than 80,000 inhabitants last year) has caused urban development southwards from its downtown. According to municipality geologic configuration, new urbanized areas are located in mountains composed of limestone with presence of karst systems. During excavation work for a sewerage system installation, a 4 x 2 x 1.5 m shallow cave was found in one planned street. For this reason, digging activities were stopped and a GPR survey was carried out on the street. A 1x1 m grid was collected using a GSSI SIR-3000 equipment. A 400 MHz frequency antenna was used for reaching 2.5 m approx. depth, attending the characteristics of the discovered cave and the excavation project depth. GPR records were calibrated in situ, thanks to the unearthed cavity. The 3D GPR-data interpretation mapped several caves only on one side of the street. The detected cavities coincided with the sewerage system layout. These underground spaces were isolated from each other, as small individual karst caves. The outcomes of this study allowed the modification of the sewerage project. Therefore, the sewerage system layout was moved to the other side of the street where no cavities were detected with the GPR survey. GPR is proved to be an efficient tool to be taken into consideration by civil engineers and architects for designing new infrastructures (e.g. sewerage systems) in urban planning areas. We conclude GPR helps minimising cost, time and inconveniences to neighbourhood during excavation works, especially in cities.

  15. Sustainable sewerage servicing options for peri-urban areas with failing septic systems.

    Science.gov (United States)

    Sharma, A K; Tjandraatmadja, G; Grant, A L; Grant, T; Pamminger, F

    2010-01-01

    The provision of water and wastewater services to peri-urban areas faces very different challenges to providing services to cities. Sustainable solutions for such areas are increasingly being sought, in order to solve the environmental and health risks posed by failing septic systems. These solutions should have the capability to reduce potable water demand, provide fit for purpose reuse options, and minimise impacts on the local and global environment. A methodology for the selection of sustainable sewerage servicing systems and technologies is presented in this paper. This paper describes the outcomes of applying this methodology to a case study in rural community near Melbourne, Australia, and describes the economic and environmental implications of various sewerage servicing options. Applying this methodology has found that it is possible to deliver environmental improvements at a lower community cost, by choosing servicing configurations not historically used by urban water utilities. The selected solution is currently being implemented, with the aim being to generate further transferable learnings for the water industry.

  16. LEAK DETECTION AND WIRELESS TELEMETRY FOR WATER DISTRIBUTION AND SEWERAGE SYSTEMS - PHASE I

    Science.gov (United States)

    According to the study EPA 2000 Community Water System Survey Data on Pipe Assets, the infrastructure for water distribution and sewerage systems is aging and requires replacement.  In addition, in EPA’s September 2002 report Clean Water and Drinking Water Infr...

  17. Optimized Real-Time Control of Combined Sewerage Systems: Two Case Studies (Proceedings Paper)

    Science.gov (United States)

    The paper presents results of two case studies of Real-Time Control (RTC) alternatives evaluations that were conducted on portions of sewerage systems near Paris, France and in Quebec City, Canada, respectively. The studies were performed at real-scale demonstration sites. RTC al...

  18. MODELING AND DESIGN OF INNOVATIVE SMALL DIAMETER GRAVITY SEWERAGE SYSTEM

    Directory of Open Access Journals (Sweden)

    Tadeusz Nawrot

    2017-05-01

    Full Text Available The article presents modern methods of hydraulic design of an innovative small diameter gravity sewerage system. In this system, domestic wastewater is preliminary treated in septic tanks equipped with outlet filters, thus the effluent features are similar to those of clear water. Innovative non-return valves at the outlets eliminate introduction of air to the system and thus the flows can be treated as one-phase ones. Computer codes EPANET 2 and SWMM 5.0 were applied and compared. Two flow schemes typical for the sewerage system were implemented in EPANET 2, and the third - in a slightly modified SWMM 5.0. Simulation results were validated on empirical data obtained on a laboratory physical model, consisting of four tanks of minimum volumes 600 dm3 each, connecting PE pipelines of diameters 25 mm and 36 mm and relevant sanitary fittings. Water inflows, typical for domestic wastewater outflows from single homesteads, were provided by a pump. Water flows were measured using water meters with pulse outputs, and water levels in tanks by pressure transducers. Hydraulic characteristics of filters and non-return valves were provided. Simulation results showed good agreement with the empirical data. Ranges of values of design parameters, needed for successful application of both codes, were established and discussed.

  19. Prague’s Sewerage System in the 1930’ and the General Sewerage Project (1933–1936

    Directory of Open Access Journals (Sweden)

    K. Drnek

    2010-01-01

    Full Text Available Prague’s sewerage system was built at the end of the era of the monarchy in the united town that Prague was transformed into. The system was soon overloaded, and was not able to remove all the sewage produced by the citizens.To deal with this hygienic threat, the city council and the management of the wastewater services undertook several actions to build a new system or improve the existing system. The most ambitious and extensive measure was the general project carried out between 1933 and 1936.The project was invented to resolve the problem once and for all by introducing new ideas and cut out the problem of placing a new sewage plant instead of the old one. For the present-day observer it also offers a range of spectacular and interesting ideas on urban wastewater treatment.

  20. The influence of supply and sewerage area characteristics on water and sewerage companies responses to the Water Framework Directive.

    Science.gov (United States)

    Spiller, M; McIntosh, B S; Seaton, R A F

    2009-01-01

    Using the example of raw water quality this paper examines the relationship between different spatial characteristics (geographical and physical properties) of Water and Sewerage Companies (WaSCs) supply and sewage areas and response to the Water Framework Directive. Results were obtained from thematic analysis and content analysis of 14 interviews with WaSCs representatives. Principal component analysis and cluster analysis of 51 WaSCs business function characteristics was employed to derive groups of similar WaSCs. Results indicate that there is difference in how WaSCs approach raw water quality issues. It appears that small WaSCs with relatively large agricultural areas in their supply catchments are more likely to seek managerial solutions to raw water quality problems.

  1. Limited influence of hospital wastewater on the microbiome and resistome of wastewater in a community sewerage system.

    Science.gov (United States)

    Buelow, Elena; Bayjanov, Jumamurat R; Majoor, Eline; Willems, Rob J L; Bonten, Marc J M; Schmitt, Heike; van Schaik, Willem

    2018-05-14

    Effluents from wastewater treatment plants (WWTPs) have been proposed to act as point sources of antibiotic-resistant bacteria (ARB) and antimicrobial resistance genes (ARGs) in the environment. Hospital sewage may contribute to the spread of ARB and ARGs as it contains the feces and urine of hospitalized patients, who are more frequently colonized with multi-drug resistant bacteria than the general population. However, whether hospital sewage noticeably contributes to the quantity and diversity of ARGs in the general sewerage system has not yet been determined.Here, we employed culture-independent techniques, namely 16S rRNA gene sequencing and nanolitre-scale quantitative PCRs, to assess the role of hospital effluent as a point source of ARGs in the sewerage system, through comparing microbiota composition and levels of ARGs in hospital sewage with WWTP influent with and without hospital sewage.Compared to other sites, hospital sewage was richest in human-associated bacteria and contained the highest relative levels of ARGs. Yet, the relative abundance of ARGs was comparable in the influent of WWTPs with and without hospital sewage, suggesting that hospitals do not contribute importantly to the quantity and diversity of ARGs in the investigated sewerage system.

  2. Design flow factors for sewerage systems in small arid communities

    OpenAIRE

    Imam, Emad H.; Elnakar, Haitham Y.

    2014-01-01

    Reliable estimation of sewage flow rates is essential for the proper design of sewers, pumping stations, and treatment plants. The design of the various components of the sewerage system should be based on the most critical flow rates with a focus on extremely low and peak flow rates that would be sustained for a duration related to the acceptable limits of behavior of the components under consideration. The extreme flow conditions and to what extent they differ from the average values are cl...

  3. An Intelligent Network Proposed for Assessing Seismic Vulnerability Index of Sewerage Networks within a GIS Framework (A Case Study of Shahr-e-Kord

    Directory of Open Access Journals (Sweden)

    Mohamadali Rahgozar

    2016-01-01

    Full Text Available Due to their vast spread, sewerage networks are exposed to considerable damages during severe earthquakes, which may lead to catastrophic environmental contamination. Multiple repairs in the pipelines, including pipe and joint fractures, could be costly and time-consuming. In seismic risk management, it is of utmost importance to have an intelligent tool for assessing seismic vulnerability index at any given point in time for such important utilities as sewerage networks. This study uses a weight-factor methodology and proposes an online GIS-based intelligent algorithm to evaluate the seismic vulnerability index (VI for metropolitan sewerage networks. The proposed intelligent tool is capable of updating VI as the sewerage network conditions may change with time and at different locations. The city of Shahr-e-Kord located on the high risk seismic belt is selected for a case study to which the proposed methodology is applied for zoning the vulnerability index in GIS. Results show that the overall seismic vulnerability index for the selected study area ranges from low to medium but that it increases in the southern parts of the city, especially in the old town where brittle pipes have been laid

  4. Provision of private, piped water and sewerage connections and directly observed handwashing of mothers in a peri-urban community of Lima, Peru.

    Science.gov (United States)

    Oswald, William E; Hunter, Gabrielle C; Kramer, Michael R; Leontsini, Elli; Cabrera, Lilia; Lescano, Andres G; Gilman, Robert H

    2014-04-01

    To estimate the association between improved water and sanitation access and handwashing of mothers living in a peri-urban community of Lima, Peru. We observed 27 mothers directly, before and after installation of private, piped water and sewerage connections in the street just outside their housing plots, and measured changes in the proportion of faecal-hand contamination and hand-to-mouth transmission events with handwashing. After provision of water and sewerage connections, mothers were approximately two times more likely to be observed washing their hands within a minute of defecation, compared with when they relied on shared, external water sources and non-piped excreta disposal (RR = 2.14, 95% CI = 0.99-4.62). With piped water and sewerage available at housing plots, handwashing with or without soap occurred within a minute after 48% (10/21) of defecation events and within 15 min prior to 8% (11/136) of handling food events. Handwashing increased following installation of private, piped water and sewerage connections, but its practice remained infrequent, particularly before food-related events. Infrastructural interventions should be coupled with efforts to promote hygiene and ensure access to water and soap at multiple on-plot locations convenient to mothers. © 2014 John Wiley & Sons Ltd.

  5. Transmission of radioiodine through sampling lines

    International Nuclear Information System (INIS)

    Unrein, P.J.; Pelletier, C.A.; Cline, J.E.; Voilleque, P.G.

    1985-01-01

    An experimental program to measure radioiodine transmission through sampling lines is described. The transmission depends upon both deposition on and resuspension from the walls of the line. The deposition and resuspension processes are themselves controlled by the length, diameter, and material of the line and the conditions under which it is operated. The operating conditions under study are sampling flow rate, temperature and relative humidity. Measurement results have been interpreted in terms of a four-compartment model of radioiodine deposition and resuspension. The model is applied to each of twenty or more segments of the line. Experimental measurements of short-term transmission fractions and the deposition velocities derived from them are presented for six lines. Data on resuspension rates for the same lines were obtained and are also discussed

  6. Discussion of 10 CRF 20 rules for waste of effluents in sanitary sewerage

    International Nuclear Information System (INIS)

    Rocha, A.C.S. da; Pina, J.L.S.

    1986-12-01

    An interpretation of the Code of Federal Regulations, volume 10 part 20 (10 CFR 20) from Nuclear Regulatory Commission is proposed, aiming at his easier use in waste of radioactive liquid effluents to the environment, by sanitary sewerage. The study is based on recommendations of International Commission of Radiological Protection (ICPR 2) and International Atomic Energy Agency (Basic Safety Standards for Radiation Protection). (M.A.C.) [pt

  7. Addressing Flooding and SuDS when Improving Drainage and Sewerage Systems—A Comparative Study of Selected Scandinavian Cities

    Directory of Open Access Journals (Sweden)

    Geir Torgersen

    2014-04-01

    Full Text Available Pluvial flooding already challenges the capacity of drainage and sewerage system in urban areas in Scandinavia. For system owners this requires a stricter prioritization when improving the systems. Experts seem to agree that a regime shift from improving old combined sewers by piped solutions to more sustainable drainage systems (SuDS, must take place. In this paper results from an investigation amongst the largest cities in Norway, Denmark and Sweden concerning drivers and preferred methods for improving the old system are presented. The results indicate that Norway ranks flood prevention lower than the other Scandinavian countries. During the last decades, Norwegian authorities have had a strong focus on pollution from wastewater treatment plants (WWTP. The attention to drainage and sewerage system regarding flooding, water leaks, infiltration or pollution has been neglected. Renewal or rate of investment in relation to existing drainage and sewerage system is easy to register, and provides a measure of the activity. In order to optimize flood prevention, and may be promoting the use of SuDS, the cities should be required to measure the efficiency, either by monitoring or modeling the impact of stormwater to the system. Lack of such requirements from Norwegian authorities seem to be a plausible explanation to why Norwegian cities are less focused on flood prevention compared to Swedish and Danish cities.

  8. Hydraulic and Condition Assessment of Existing Sewerage Network: A Case Study of an Educational Institute

    Science.gov (United States)

    Sourabh, Nishant; Timbadiya, P. V.

    2018-04-01

    The hydraulic simulation of the existing sewerage network provides various information about critical points to assess the deteriorating condition and help in rehabilitation of existing network and future expansion. In the present study, hydraulic and condition assessment of existing network of educational Institute (i.e. Sardar Vallabhbhai National Institute of Technology-Surat, Gujarat, India), having an area of 100 ha and ground levels in range of 5.0-9.0 m above mean sea level, has been carried out using sewage flow simulation for existing and future scenarios analysis using SewerGEMS v8i. The paper describes the features of 4.79 km long sewerage network of institute followed by network model simulation for aforesaid scenarios and recommendations on improvement of the existing network for future use. The total sewer loads for present and future scenarios are 1.67 million litres per day (MLD) and 3.62 MLD, considering the peak factor of 3 on the basis of population. The hydraulic simulation of the existing scenario indicated depth by diameter (d/D) ratio in the range of 0.02-0.48 and velocity range of 0.08-0.53 m/s for existing network for present scenario. For the future scenario, the existing network is needed to be modified and it was found that total of 11 conduits (length: 464.8 m) should be replaced to the next higher diameter available, i.e., 350 mm for utilization of existing network for future scenario. The present study provides the methodology for condition assessment of existing network and its utilization as per guidelines provided by Central Public Health and Environmental Engineering Organization, 2013. The methodology presented in this paper can be used by municipal/public health engineer for the assessment of existing sewerage network for its serviceability and improvement in future.

  9. Radar-based alert system to operate a sewerage network: relevance and operational effectiveness after several years of use.

    Science.gov (United States)

    Faure, D; Payrastre, O; Auchet, P

    2005-01-01

    Since January 2000, the sewerage network of a very urbanised catchment area in the Greater Nancy Urban Community has been operated according to the alarms generated in real time by a storm alert system using weather radar data. This alert system is based on an automatic identification of intense rain cells in the radar images. This paper presents the characteristics of this alert system and synthesises the main results of two complementary studies realised in 2002 in order to estimate the relevance and the operational effectiveness of the alert system. The first study consisted in an off-line analysis of almost 50,000 intense rain cells detected in four years of historical radar data. The second study was an analysis of the experience feedback after two years of operational use of this alert system. The results of these studies are discussed in function of the initial operational objectives.

  10. Chemical analysis of sewage sludge of southern sewerage treatment plant (SSTP) Hyderabad for achieving sustainable development in sector of agriculture

    International Nuclear Information System (INIS)

    Qureshi, K.; Shaikh, N.; Ahmed, R.S.; Nawaz, Z.

    2003-01-01

    A study on the chemical analysis of sewage sludge of southern sewerage treatment plant (SSPP) Hyderabad was studied. Chemical analysis on sludge samples collected form the waste stabilization for different micro-nutrients (essential manures, nitrogen, phosphorus, potassium, calcium and magnesium) were conducted in year 1999-2000. These nutrients and metal were detected by reliable analytical method i.e. Kjeldahls method and Atomic Absorption Spectrophotometer. The analysis showed that sewage sludge contained sufficient quantity of primary and secondary nutrients, hence sewage sludge could be utilized as a natural fertilizer. This will not only solve the disposal problem but it would also be environmentally safer way of providing regulators to the plants. (author)

  11. Investigation of the motion processes of wastewater in sewerage of high-rise buildings

    Directory of Open Access Journals (Sweden)

    Pomogaeva Valentina

    2018-01-01

    Full Text Available When designing, constructing and operating sewage pipelines in high-rise buildings, issues of failure-free operation of a network arise. Investigation of the processes of wastewater moving allows identifying problem areas during operation, assessing the possibility of obstructions and breakdowns of plumbing traps on the gravity drainage sections of the pipeline. The article performs the schemes of the water outflow from the floor sewer into the riser, including the places where the riser is bent, of air delivery to the working riser under the change of the direction of drain movement with the dropout line set-up, with the installation of an automatic anti-vacuum valve, with the installation of the ventilation pipeline. Investigations of the process of sewage waste flow in a sewage riser were carried out, in order to select the appropriate structure. The authors consider structure features of some sections of sewerage in high-rise buildings. The exhaustion value in the riser is determined from the rarefactions that occur below the compressed cross-section of the riser and the loss of the air flow pressure coming from the atmosphere into the riser during the deflooding of the liquid. Preventing the formation of obstructions and breakdowns of plumbing traps is an integral part of sewage networks.

  12. Investigation of the motion processes of wastewater in sewerage of high-rise buildings

    Science.gov (United States)

    Pomogaeva, Valentina; Metechko, Lyudmila; Prokofiev, Dmitry; Narezhnaya, Tamara

    2018-03-01

    When designing, constructing and operating sewage pipelines in high-rise buildings, issues of failure-free operation of a network arise. Investigation of the processes of wastewater moving allows identifying problem areas during operation, assessing the possibility of obstructions and breakdowns of plumbing traps on the gravity drainage sections of the pipeline. The article performs the schemes of the water outflow from the floor sewer into the riser, including the places where the riser is bent, of air delivery to the working riser under the change of the direction of drain movement with the dropout line set-up, with the installation of an automatic anti-vacuum valve, with the installation of the ventilation pipeline. Investigations of the process of sewage waste flow in a sewage riser were carried out, in order to select the appropriate structure. The authors consider structure features of some sections of sewerage in high-rise buildings. The exhaustion value in the riser is determined from the rarefactions that occur below the compressed cross-section of the riser and the loss of the air flow pressure coming from the atmosphere into the riser during the deflooding of the liquid. Preventing the formation of obstructions and breakdowns of plumbing traps is an integral part of sewage networks.

  13. Water-resources-related information for the Milwaukee Metropolitan Sewerage District planning area, Wisconsin, 1970-2002

    Science.gov (United States)

    Schneider, Morgan A.; Lutz, Michelle A.; ,

    2004-01-01

    The Milwaukee Metropolitan Sewerage District (MMSD) Corridor Study is a three-phase project designed to improve the understanding of water resources in the stream corridors of the MMSD planning area by initially compiling existing data and using the compiled information to develop 3-year baseline and long-term monitoring plans. This report is one of the products of Phase I of the Corridor Study.

  14. Innovative sewerage solutions for small rural towns.

    Science.gov (United States)

    Diaper, C; Sharma, A

    2007-01-01

    The development and implementation of alternative wastewater servicing approaches in rural communities in Australia appears more feasible than in larger urban developments as many rural centres rely on septic tanks and surface discharge of greywater. This method of disposal creates many environmental, social and economic issues and is seen to limit potential for growth in many towns. This paper describes a generic methodology for the selection of innovative sewerage options for six regional towns in Victoria, Australia. The method includes consultation with stakeholders, multi-criteria assessment and concept design of the most favourable option. Despite the broad range of initial wastewater servicing options presented which included cluster-scale systems, upgrade of existing systems, greywater reuse and alternative collection, the outcome for five of the six towns was a modified centralised collection system as the preferred option. Lack of robust and reliable data on the human health risks and environmental impacts of alternative systems were identified as the primary data gaps in the sustainability assessment. In addition, biases in the assessment method due to stakeholder perceptions were found to be an additional issue.

  15. Application of toxicity monitor using nitrifying bacteria biosensor to sewerage systems.

    Science.gov (United States)

    Inui, T; Tanaka, Y; Okayas, Y; Tanaka, H

    2002-01-01

    Toxic substances may be included in wastewater influent and can damage biological processing of wastewater treatment, therefore continuous toxic-monitoring of wastewater influent is needed. This paper describes the potential toxic-monitoring applications of the toxicity monitor using a nitrifying bacteria biosensor to sewerage systems. The results of sensitivity tests show that aspects of wastewater do not affect the sensor sensitivity and confirm that the sensor can be applied to wastewater monitoring as it is. The monitor with a prototype of filtration system installed in a wastewater treatment plant is able to operate continuously for one month at least after the modification of filtration system and the optimization of operation conditions.

  16. Amount of deposited by river silt Cs-137 brought to the river Arbuzynka with sewerage water from South Ukrainian Atomic Power Plant

    International Nuclear Information System (INIS)

    Vyintsukevich, N.V.; Tomyilyin, Yu.A.; Grigor'jeva, L.Yi.

    1996-01-01

    The peculiarities of radionuclide depositing in the silt of the river Arbuzynka in the place of discharge of sewerage water from South Ukrainian Atomic Power Plant have been studied. According to the finding of the observation, the main contribution to the total radioactivity of the sewerage water for the entire period of the plant operation was made by Cs-137. The greatest contamination of the river was observed in 1988 and 1993. It has been established that for the whole period of the plant operation two processes developed dynamically in the Arbuzynka, e.i. Cs-137 accumulation by the bottom deposits and its reserve receipt by the water. The process of accumulation was more dynamic

  17. HASE - The Helsinki adaptive sample preparation line

    Energy Technology Data Exchange (ETDEWEB)

    Palonen, V., E-mail: vesa.palonen@helsinki.fi [Department of Physics, University of Helsinki, P.O. Box 43, FI-00014 (Finland); Pesonen, A. [Laboratory of Chronology, Finnish Museum of Natural History, P.O. Box 64, FI-00014 (Finland); Herranen, T.; Tikkanen, P. [Department of Physics, University of Helsinki, P.O. Box 43, FI-00014 (Finland); Oinonen, M. [Laboratory of Chronology, Finnish Museum of Natural History, P.O. Box 64, FI-00014 (Finland)

    2013-01-15

    We have designed and built an adaptive sample preparation line with separate modules for combustion, molecular sieve handling, CO{sub 2} gas cleaning, CO{sub 2} storage, and graphitization. The line is also connected to an elemental analyzer. Operation of the vacuum equipment, a flow controller, pressure sensors, ovens, and graphitization reactors are automated with a reliable NI-cRIO real-time system. Stepped combustion can be performed in two ovens at temperatures up to 900 Degree-Sign C. Depending on the application, CuO or O{sub 2}-flow combustion can be used. A flow controller is used to adjust the O{sub 2} flow and pressure during combustion. For environmental samples, a module for molecular sieve regeneration and sample desorption is attached to the line replacing the combustion module. In the storage module, CO{sub 2} samples can be stored behind a gas-tight diaphragm valve and either stored for later graphitization or taken for measurements with separate equipment (AMS gas ion source or a separate mass spectrometer). The graphitization module consists of four automated reactors, capable of graphitizing samples with masses from 3 mg down to 50 {mu}g.

  18. Line Shape Variability in a Sample of AGN with Broad Lines

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... We give here a comparative review of the line shape variability in a sample of five type 1 AGNs, those with broad emission lines in their spectra, of the data obtained from the international long-term optical monitoring campaign coordinated by the Special Astrophysical Observatory of the Russian Academy ...

  19. On-line sample treatment - Capillary gas chromatography

    NARCIS (Netherlands)

    Goosens, EC; de Jong, D; de Jong, GJ; Brinkman, UAT

    Sample pretreatment is often the bottleneck of a trace level analytical procedure. In order to increase performance, increasing attention is therefore being devoted to combining sample pretreatment on-line with the separation technique that has to be used. In the present review, a variety of

  20. Radioactive and electron microscope analysis of effluent monitor sample lines

    International Nuclear Information System (INIS)

    Kowalski, J.F.

    1986-01-01

    Effluent air sampling at nuclear power plant often leads to the question ''How representative is the sample of the effluent stream?'' Samples from radiation monitors are typically obtained at great distances from the sample nozzle because of high background concerns under postulated accidents. Sample line plateout during normal effluent sampling becomes the major concern. A US Nuclear Regulatory Commission inspection raised a concern that monitors were not collecting representative samples per ANSI standard N13.1. A comprehensive 2-yr study at Beaver Valley was performed during normal effluent releases in two phases: 1) weekly charcoal and glass fiber filter samples were analyzed for radioactivity for 6 months, and 2) nuclepore membrane filter samples were analyzed by electron microscope for 4- and 6-h periods. A specially designed test nozzle was directly inserted into an effluent stream for comparison with the radiation monitor samples. Particle behavior characteristics can be determined during effluent releases using a simple test probe. While particle plateout was the major purpose of the study, other particle behavior characteristics were evident and equally as important. Particle travel through long sample lines can also lead to (a) agglomeration or the coagulation of smaller particles to form larger ones, (b) particle splitting or fracturing upon impact with the sample line interior walls, and (c) resuspension of large particles in sample lines

  1. Report: Association of Metropolitan Sewerage Agencies - Costs Claimed Under EPA Cooperative Agreements X827577-01, X828302-01, and X829595-01

    Science.gov (United States)

    Report #2004-4-00038, August 31, 2004. The Association of Metropolitan Sewerage Agencies’ (recipient) financial management and procurement systems need to be improved to fully comply with the requirements of Title 40 CFR Part 30 and OMB Circular A-122.

  2. Edge Effects in Line Intersect Sampling With

    Science.gov (United States)

    David L. R. Affleck; Timothy G. Gregoire; Harry T. Valentine

    2005-01-01

    Transects consisting of multiple, connected segments with a prescribed configuration are commonly used in ecological applications of line intersect sampling. The transect configuration has implications for the probability with which population elements are selected and for how the selection probabilities can be modified by the boundary of the tract being sampled. As...

  3. The role of environmental variables on the efficiency of water and sewerage companies: a case study of Chile.

    Science.gov (United States)

    Molinos-Senante, María; Sala-Garrido, Ramón; Lafuente, Matilde

    2015-07-01

    This paper evaluates the efficiency of water and sewerage companies (WaSCs) by introducing the lack of service quality as undesirable outputs. It also investigates whether the production frontier of WaSCs is overall constant returns to scale (CRS) or variable returns to scale (VRS) by using two different data envelopment analysis models. In a second-stage analysis, we study the influence of exogenous and endogenous variables on WaSC performance by applying non-parametric hypothesis tests. In a pioneering approach, the analysis covers 18 WaSCs from Chile, representing about 90% of the Chilean urban population. The results evidence that the technology of the sample studied is characterized overall by CRS. Peak water demand, the percentage of external workers, and the percentage of unbilled water are the factors affecting the efficiency of WaSCs. From a policy perspective, the integration of undesirable outputs into the assessment of WaSC performance is crucial not to penalize companies that provide high service quality to customers.

  4. Draft Genome Sequence of Bacillus aryabhattai Strain PHB10, a Poly(3-Hydroxybutyrate)-Accumulating Bacterium Isolated from Domestic Sewerage.

    Science.gov (United States)

    Balakrishna Pillai, Aneesh; Jaya Kumar, Arjun; Thulasi, Kavitha; Reghunathan, Dinesh; Prasannakumar, Manoj; Kumarapillai, Harikrishnan

    2017-10-12

    Bacillus aryabhattai PHB10 is a poly(3-hydroxybutyrate) (PHB)-accumulating bacterium isolated from domestic sewerage. Here, we report the 4.19-Mb draft genome sequence, with 4,050 protein-coding genes and a G+C content of 37.5%. This sequence will be helpful in the study of the high-level PHB accumulation mechanism of the strain. Copyright © 2017 Balakrishna Pillai et al.

  5. Historical Transition of Eco-Structure in a Tidal Flat Caused by Expansion of Sewerage Treatment Area

    Directory of Open Access Journals (Sweden)

    Hideki Tatsumoto

    2004-01-01

    Full Text Available An artificial tidal flat was prepared for the mitigation tool on coastal environment. However, it is considered that most of the flat was not restored to the sufficient amenities for aquatic living things, migratory birds, etc. because none of the ecological mechanisms were understood or planned for. It is therefore investigated in this paper that historical transition factors in ecosystem structure are selected and traced with the diffusion of a public sewerage system, and with environmental factors such as water quality, sediment condition, and aquatic producers in the Yatsu Tidal Flat. As a result, it can be defined that the tidal flat, just like a lagoon, was formed artificially with reclamation and development of its circumference at the first step of transition; the water quality and sediment condition gradually became brackish water and muddy sediment conditions, interactively. The ecosystem pyramid forming orderly layers according to trophic level appeared as a high-bio-production potential in its tidal flat. In the second step, i.e., in recent years, the characteristics of water quality and sediment conditions evolved into a foreshore tidal flat, namely, conditions in the flat observed were that the progression of water included a high concentration of chloride ion as seawater and sediment conditions became sandy. Because of that, the inflowing fresh water and organic mater from the land area decreased with the improvement of the public sewerage system. The ecosystem pyramid was distorted into a chaos pyramid, with inversion of Ulva spp.

  6. Historical transition of eco-structure in a tidal flat caused by expansion of sewerage treatment area.

    Science.gov (United States)

    Tatsumoto, Hideki; Ishii, Yuichi; Machida, Motoi; Taki, Kazuo

    2004-05-11

    An artificial tidal flat was prepared for the mitigation tool on coastal environment. However, it is considered that most of the flat was not restored to the sufficient amenities for aquatic living things, migratory birds, etc. because none of the ecological mechanisms were understood or planned for. It is therefore investigated in this paper that historical transition factors in ecosystem structure are selected and traced with the diffusion of a public sewerage system, and with environmental factors such as water quality, sediment condition, and aquatic producers in the Yatsu Tidal Flat. As a result, it can be defined that the tidal flat, just like a lagoon, was formed artificially with reclamation and development of its circumference at the first step of transition; the water quality and sediment condition gradually became brackish water and muddy sediment conditions, interactively. The ecosystem pyramid forming orderly layers according to trophic level appeared as a high-bio-production potential in its tidal flat. In the second step, i.e., in recent years, the characteristics of water quality and sediment conditions evolved into a foreshore tidal flat, namely, conditions in the flat observed were that the progression of water included a high concentration of chloride ion as seawater and sediment conditions became sandy. Because of that, the inflowing fresh water and organic mater from the land area decreased with the improvement of the public sewerage system. The ecosystem pyramid was distorted into a chaos pyramid, with inversion of Ulva spp.

  7. Oxygen consumption by hydrazine in long sample lines

    International Nuclear Information System (INIS)

    Chi, Lisheng; Turner, Carl-W.

    2012-09-01

    In nuclear power plants secondary side system dissolved oxygen concentration is a strictly controlled chemistry parameter intended to minimize corrosion and fouling of steam cycle components. Low dissolved oxygen concentration is maintained by a combination of mechanical de-aeration and chemical reaction. The dissolved oxygen concentration in feedwater is monitored by sampling systems to ensure it remains within station specification during operation. The sample lines in a nuclear power plant's sampling system can be from 5 to nearly 200 meters in length, resulting in sample residence times between the take-off point to the analyzer from a few seconds to several minutes, depending on the flow rate and the length of the sample line. For many chemical parameters the residence time is of no concern. For measurements of dissolved oxygen and hydrazine in the secondary coolant, however, for residence times longer than one minute, it is uncertain whether the sample is representative of conditions in the secondary coolant, especially for samples taken from locations where the temperature is well over 100 deg. C. To address this concern, a series of tests were conducted under both warm-up and power operation conditions, respectively, to investigate the effect of temperature, residence time, sample line length, surface area, hydrazine-to-oxygen ratio, and the concentrations of dissolved oxygen and hydrazine on the consumption of oxygen by hydrazine. The test results revealed that dissolved oxygen measurements in CANDU plants are underestimated to various degrees, depending on the sampling system operating conditions. Two distinct types of behaviours are observed for the oxygen removal rate: 1) the percentage removal of dissolved oxygen is invariant with time during the tests, and increases with increasing residence time in the test section, when the reaction between hydrazine and oxygen is better described by a homogenous reaction mechanism, and 2) the percentage oxygen

  8. Suitability of the line intersect method for sampling hardwood logging residues

    Science.gov (United States)

    A. Jeff Martin

    1976-01-01

    The line intersect method of sampling logging residues was tested in Appalachian hardwoods and was found to provide unbiased estimates of the volume of residue in cubic feet per acre. Thirty-two chains of sample line were established on each of sixteen 1-acre plots on cutover areas in a variety of conditions. Estimates from these samples were then compared to actual...

  9. Sample handling and transport for the Secure Automated Fabrication line

    International Nuclear Information System (INIS)

    Sherrell, D.L.; Jensen, J.D.; Genoway, G.G.; Togesen, H.J.

    1983-06-01

    A totally automated system is described which packages, transports, receives, and unpackages sintered plutonium/uranium oxide fuel pellet samples to support automated chemical analysis equipment for the Secure Automated Fabrication (SAF) line. Samples are transferred 100 meters from the fuel production line to a different floor of the facility where automatic determinations are made for purposes of process control and fuel quality certification. The system automatically records identification numbers, net weights sent and received, and all other pertinent information such as fuel lot number, sample point, date, and time of day

  10. DAMAGE ASSESSMENT ON WATER SUPPLY SYSTEM AND SEWERAGE SYSTEM AT THE 2011 OFF THE PACIFIC COAST OF TOHOKU EARTHQUAKE - CASE STUDY FOR THE DATA AT IBARAKI AND CHIBA PREFECTURES

    Science.gov (United States)

    Naba, Satoshi; Tsukiji, Takuya; Shoji, Gaku; Nagata, Shigeru

    We evaluate the dependency of damage and restoration of water supply systems and sewerage system on the seismic hazards in the 2011 off the Pacific Coast of Tohoku earthquake focusing on the damage at Ibaraki and Chiba prefectures. We use the damage data of the systems by carrying out field survey, interviews for related local government sectors and surveying the information in web sites. We quantify two damage ratios defined by the ratio of number of physical damage points Np with the related pipeline lengths L and that of disrupted lengths Ld with L. In addition, we discuss relation between restoration periods with the seismic hazards. Finally, we verify the fitting of the damage data with previous seismic fragility curves on sewerage pipelines.

  11. Transfer of glyphosate and its degradate AMPA to surface waters through urban sewerage systems.

    Science.gov (United States)

    Botta, Fabrizio; Lavison, Gwenaëlle; Couturier, Guillaume; Alliot, Fabrice; Moreau-Guigon, Elodie; Fauchon, Nils; Guery, Bénédicte; Chevreuil, Marc; Blanchoud, Hélène

    2009-09-01

    A study of glyphosate and aminomethyl phosphonic acid (AMPA) transfer in the Orge watershed (France) was carried out during 2007 and 2008. Water samples were collected in surface water, wastewater sewer, storm sewer and wastewater treatment plant (WWTP). These two molecules appeared to be the most frequently detected ones in the rivers and usually exceeded the European quality standard concentrations of 0.1microg L(-1) for drinking water. The annual glyphosate estimated load was 1.9 kg year(-1) upstream (agricultural zone) and 179.5 kg year(-1) at the catchment outlet (urban zone). This result suggests that the contamination of this basin by glyphosate is essentially from urban origin (road and railway applications). Glyphosate reached surface water prevalently through storm sewer during rainfall event. Maximum concentrations were detected in storm sewer just after a rainfall event (75-90 microg L(-1)). High concentrations of glyphosate in surface water during rainfall events reflected urban runoff impact. AMPA was always detected in the sewerage system. This molecule reached surface water mainly via WWTP effluent and also through storm sewer. Variations in concentrations of AMPA during hydrological episodes were minor compared to glyphosate variations. Our study highlights that AMPA and glyphosate origins in urban area are different. During dry period, detergent degradation seemed to be the major AMPA source in wastewater.

  12. Occurrence of multi-class surfactants in urban wastewater: contribution of a healthcare facility to the pollution transported into the sewerage system.

    Science.gov (United States)

    Bergé, Alexandre; Wiest, Laure; Baudot, Robert; Giroud, Barbara; Vulliet, Emmanuelle

    2018-04-01

    Healthcare facility discharges, by their nature, are often considered as non-domestic effluent, which can provide significant pollution comparatively to other domestic sources. In this context, a total of 12 monthly sampling campaigns were collected from a healthcare facility as well as the output of a sewerage system of Site Pilote de Bellecombe (SIPIBEL) observatory. This study focuses more specifically on 12 surfactants and biocides: four anionics, four cationic, two non-ionic, one zwitterionic, and one dispersive agent, among the most commonly used commercial surfactants. Particular attention was also provided to routine wastewater quality parameters. Both effluents were heavily contaminated by most anionic surfactants; they displayed median concentrations up to 1 to 2 mg/L for linear alkylbenzene sulfonates and between 10 and 100 μg/L for other sodium sulfate congeners (lauryl and laureth). Overall, for the majority of surfactants, the healthcare facility contribution to the total flux reaching the wastewater treatment plant ranges between 5 and 9%.

  13. Evaluating hepatocellular carcinoma cell lines for tumour samples using within-sample relative expression orderings of genes.

    Science.gov (United States)

    Ao, Lu; Guo, You; Song, Xuekun; Guan, Qingzhou; Zheng, Weicheng; Zhang, Jiahui; Huang, Haiyan; Zou, Yi; Guo, Zheng; Wang, Xianlong

    2017-11-01

    Concerns are raised about the representativeness of cell lines for tumours due to the culture environment and misidentification. Liver is a major metastatic destination of many cancers, which might further confuse the origin of hepatocellular carcinoma cell lines. Therefore, it is of crucial importance to understand how well they can represent hepatocellular carcinoma. The HCC-specific gene pairs with highly stable relative expression orderings in more than 99% of hepatocellular carcinoma but with reversed relative expression orderings in at least 99% of one of the six types of cancer, colorectal carcinoma, breast carcinoma, non-small-cell lung cancer, gastric carcinoma, pancreatic carcinoma and ovarian carcinoma, were identified. With the simple majority rule, the HCC-specific relative expression orderings from comparisons with colorectal carcinoma and breast carcinoma could exactly discriminate primary hepatocellular carcinoma samples from both primary colorectal carcinoma and breast carcinoma samples. Especially, they correctly classified more than 90% of liver metastatic samples from colorectal carcinoma and breast carcinoma to their original tumours. Finally, using these HCC-specific relative expression orderings from comparisons with six cancer types, we identified eight of 24 hepatocellular carcinoma cell lines in the Cancer Cell Line Encyclopedia (Huh-7, Huh-1, HepG2, Hep3B, JHH-5, JHH-7, C3A and Alexander cells) that are highly representative of hepatocellular carcinoma. Evaluated with a REOs-based prognostic signature for hepatocellular carcinoma, all these eight cell lines showed the same metastatic properties of the high-risk metastatic hepatocellular carcinoma tissues. Caution should be taken for using hepatocellular carcinoma cell lines. Our results should be helpful to select proper hepatocellular carcinoma cell lines for biological experiments. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. APLICATION OF ABC METHOD FROM AN OPERATOR OF WATER AND SEWERAGE

    Directory of Open Access Journals (Sweden)

    FÜLÖP ÁRPÁD-ZOLTÁN

    2016-12-01

    Full Text Available At the time of the appearance of the ABC method, many specialists considered that they found the most opportune method of calculation to allocate the overhead costs on the cost objects, otherwise said to be able to calculate the total cost of a product or service. Because the method is based on determining the total cost, we can consider that the ABC method is not a method of costing, but rather a method of cost management. Unfortunately, in the specialized literature of Roumania there are many approaches which consider that the ABC method is a method of costing in the traditional way, although in our opinion it is not. Application of ABC method to a regional operator of water and sewerage shows us the possibilities of the method, the possibilities that are offered in the field of cost and administration overhead management, respectively of the establishment of the accounting result on the different cost objects. In case of the regional operator the calculation object is the city or township in which provides the services of water and sewage.

  15. Analysis quality of content digital plan of cadastre lines (underground installation

    Directory of Open Access Journals (Sweden)

    Marinković Goran

    2016-01-01

    Full Text Available This work presents the results of research quality digital geodetic plans lines and underground installations. The study included the creation of a digital geodetic plan sewerage network vectorization of analogue geodetic plans and creation of digital geodetic plan of the same details from the original data survey and maintenance survey. Based on research results the analysis of the accuracy and reliability digital geodetic plan created vectoring analogue plan or 'digitizing from the screen'. The results obtained in this work, the can be use not only in the Republic of Serbia, but also in other countries where digitalization of geodetic plans are increasingly gaining in importance.

  16. Charaxteristics and malfunctions of the drinking water supply and sewerage network in Satu Mare.

    Directory of Open Access Journals (Sweden)

    C. O. MAREŞ

    2017-10-01

    Full Text Available The beginnings of centralized drinking water supply in the metropolitan area date back to the beginning of the 20th century when a project is being developed focusing on the underground sources afferent to Somes' alluvial cone at the expense of other sources. The source raises the issue of water deferring and demanganizing due to its high Fe and Mn content. The age of the adduction network causes defects that require rehabilitation of the old supply chain trunks. The sewage capacity - the discharge of meteoric and domestic water is outweighed by heavy rainfall resulting in outbreaks in certain urban areas with floods in inland waters. The phenomenon is favored by the flatness of the relief, the clogging of the evacuation network and the inconsistency between the urban dynamics and the existing sewerage network.

  17. Design unbiased estimation in line intersect sampling using segmented transects

    Science.gov (United States)

    David L.R. Affleck; Timothy G. Gregoire; Harry T. Valentine; Harry T. Valentine

    2005-01-01

    In many applications of line intersect sampling. transects consist of multiple, connected segments in a prescribed configuration. The relationship between the transect configuration and the selection probability of a population element is illustrated and a consistent sampling protocol, applicable to populations composed of arbitrarily shaped elements, is proposed. It...

  18. Development and commissioning of decision support tools for sewerage management.

    Science.gov (United States)

    Manic, G; Printemps, C; Zug, M; Lemoine, C

    2006-01-01

    Managing sewerage systems is a highly complex task due to the dynamic nature of the facilities. Their performance strongly depends on the know-how applied by the operators. In order to define optimal operational settings, two decision support tools based on mathematical models have been developed. Moreover, easy-to-use interfaces have been created as well, aiding operators who presumably do not have the necessary skills to use modelling software. The two developed programs simulate the behaviour of both wastewater treatment plants (WWTP) and sewer network systems, respectively. They have essentially the same structure, including raw data management and statistical analysis, a simulation layer using the application programming interface of the applied software and a layer responsible for the representation of the obtained results. Four user modes are provided in the two software including the simulation of historical data using the applied and novel operational settings, as well as modes concerning prediction of possible operation periods and updates. Concerning the WWTP software, it was successfully installed in Nantes (France) in June 2004. Moreover, the one managing sewer networks has been deployed in Saint-Malo (France) in January 2005. This paper presents the structure of the developed software and the first results obtained during the commissioning phase.

  19. Influence of radioactive fallout on water supply and sewerage in Finland; Radioaktiivisen laskeuman vaikutukset vesihuoltoon

    Energy Technology Data Exchange (ETDEWEB)

    Rantavaara, A; Saxen, R; Puhakainen, M [Finnish Centre for Radiation and Nuclear Safety, Helsinki (Finland); Hatva, T; Ahosilta, P; Tenhunen, J [National Board of Waters and the Environment, Helsinki (Finland)

    1995-09-01

    The report reviews the practices and organization of water supply and sewerage in Finland and is related to their response to radioactive fallout situations. The contribution of drinking water to the internal radiation dose caused by radioactive fallout has earlier been small in Finland. However, in a wide-scale fallout situation, the decreasing of collective dose received from water may be justified, if the dose can be reduced at a reasonable cost, for instance by a temporary change of the raw water source. Efficient exchange of information between radiation protection and water supply experts is important for successful dose reduction measures. In Finland waterworks deliver tap water to 4.2 million people. Half of the water is ground water, and generally very well protected against fallout radioactivity. The other half is treated surface water. (6 figs., 5 tabs.).

  20. Potential of Micro Hydroelectric Generator Embedded at 30,000 PE Effluent Discharge of Sewerage Treatment Plant

    Science.gov (United States)

    Che Munaaim, M. A.; Razali, N.; Ayob, A.; Hamidin, N.; Othuman Mydin, M. A.

    2018-03-01

    A micro hydroelectric generator is an energy conversion approach to generate electricity from potential (motion) energy to an electrical energy. In this research, it is desired to be implemented by using a micro hydroelectric generator which is desired to be embedded at the continuous flow of effluent discharge point of domestic sewerage treatment plant (STP). This research evaluates the potential of electricity generation from micro hydroelectric generator attached to 30,000 PE sewerage treatment plant. The power output obtained from calculation of electrical power conversion is used to identify the possibility of this system and its ability to provide electrical energy, which can minimize the cost of electric bill especially for the pumping system. The overview of this system on the practical application with the consideration of payback period is summarized. The ultimate aim of the whole application is to have a self-ecosystem electrical power generated for the internal use of STP by using its own flowing water in supporting the sustainable engineering towards renewable energy and energy efficient approach. The results shows that the output power obtained is lower than expected output power (12 kW) and fall beyond of the range of a micro hydro power (5kW - 100kW) since it is only generating 1.58 kW energy by calculation. It is also observed that the estimated payback period is longer which i.e 7 years to recoup the return of investment. A range of head from 4.5 m and above for the case where the flow shall at least have maintained at 0.05 m3/s in the selected plant in order to achieved a feasible power output. In conclusion, wastewater treatment process involves the flowing water (potential energy) especially at the effluent discharge point of STP is possibly harvested for electricity generation by embedding the micro hydroelectric generator. However, the selection of STP needs to have minimum 4.5 meter head with 0.05 m3/s of continuously flowing water to make

  1. Potential of Micro Hydroelectric Generator Embedded at 30,000 PE Effluent Discharge of Sewerage Treatment Plant

    Directory of Open Access Journals (Sweden)

    Che Munaaim M.A.

    2018-01-01

    Full Text Available A micro hydroelectric generator is an energy conversion approach to generate electricity from potential (motion energy to an electrical energy. In this research, it is desired to be implemented by using a micro hydroelectric generator which is desired to be embedded at the continuous flow of effluent discharge point of domestic sewerage treatment plant (STP. This research evaluates the potential of electricity generation from micro hydroelectric generator attached to 30,000 PE sewerage treatment plant. The power output obtained from calculation of electrical power conversion is used to identify the possibility of this system and its ability to provide electrical energy, which can minimize the cost of electric bill especially for the pumping system. The overview of this system on the practical application with the consideration of payback period is summarized. The ultimate aim of the whole application is to have a self-ecosystem electrical power generated for the internal use of STP by using its own flowing water in supporting the sustainable engineering towards renewable energy and energy efficient approach. The results shows that the output power obtained is lower than expected output power (12 kW and fall beyond of the range of a micro hydro power (5kW - 100kW since it is only generating 1.58 kW energy by calculation. It is also observed that the estimated payback period is longer which i.e 7 years to recoup the return of investment. A range of head from 4.5 m and above for the case where the flow shall at least have maintained at 0.05 m3/s in the selected plant in order to achieved a feasible power output. In conclusion, wastewater treatment process involves the flowing water (potential energy especially at the effluent discharge point of STP is possibly harvested for electricity generation by embedding the micro hydroelectric generator. However, the selection of STP needs to have minimum 4.5 meter head with 0.05 m3/s of continuously flowing

  2. Thermotolerant coliform loadings to coastal areas of Santa Catarina (Brazil) evidence the effect of growing urbanisation and insufficient provision of sewerage infrastructure.

    Science.gov (United States)

    Garbossa, Luis H P; Souza, Robson V; Campos, Carlos J A; Vanz, Argeu; Vianna, Luiz F N; Rupp, Guilherme S

    2017-01-01

    Thermotolerant coliform (TC) loadings were quantified for 49 catchments draining into the North and South Bays of Santa Catarina (SC, southeastern Brazil), an area known for its tourism and aquaculture. TC loadings were calculated based on flow measurements taken in 26 rivers. TC concentrations ere quantified based on surface water samples collected at 49 catchment outlets in 2012 and 2013. Median TC loads ranged from 3.7 × 10 3 to 6.8 × 10 8 MPN s -1 . TC loadings in the catchments increased in proportion to increases in resident human population, population density and percentage of urbanised area. Catchments with more than 60% of area covered by wastewater collection and treatment systems had higher TC loads per person than catchments with less than 25%. Based on the study catchments, these results indicate that current sewerage infrastructure is ineffective in reducing contamination of faecal origin to surface waters. These findings have important implications for the management of microbiological health hazards in bathing, recreational and shellfish aquaculture waters in the North and South Bays of Santa Catarina Island.

  3. Sewerage Pumping Stations, City_ssLiftstations, Public and Privately owned sanitary lift stations located in Glynn County and the City of Brunswick., Published in Not Provided, 1:2400 (1in=200ft) scale, Glynn County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Sewerage Pumping Stations dataset current as of unknown. City_ssLiftstations, Public and Privately owned sanitary lift stations located in Glynn County and the City...

  4. A line-based vegetation sampling technique and its application in ...

    African Journals Online (AJOL)

    percentage cover, density and intercept frequency) and also provides plant size distributions, yet requires no more sampling effort than the line-intercept method.. A field test of the three techniques in succulent karoo, showed that the discriminating ...

  5. Investigations of biofilms in the sewerage system of a highly contaminated industrial and mining area for the localization of heavy metal sources. Final report

    International Nuclear Information System (INIS)

    Cichos, C.; Singliar, U.

    1993-02-01

    The high heavy metal loading of the river Freiberger Mulde is largely caused by contaminations arising from the drainage area of the town of Freiberg. The diffuse input from the dewatering surface likely makes an important contribution to this pollution. The elimination of the reasons for the pollutant input into the sewerage and, thus, for the extremely high contamination of the sewage sludges requires a localization of sources and transport ways. For this purpose the method of investigation of biofilms on the sewer surface can be applied as a reliable method. For the industrial and mining area of Freiberg besides the different branches of industry especially the secondary emissions from deposits of old mining and metallurgical plants as well as from the extremely loaded surface of soil play an important role. The investigation of sewerage biofilms in the area considered have shown that the input of nickel and tin into the sewer is mainly caused by industry. Sources of zinc and copper above all are domestic wastewaters, whereas lead is originated from the surface run-off. Especially high pollutions of arsen and cadmium were found obviously arising from mining and production scraps. The results obtained should be the basis of activities for definite interruption of the pollutant input into the sewer system. They are a contribution to the restoration of the hydrographical network of Mulde/Elbe. (orig.) [de

  6. Drinking water quality in urban areas of pakistan a case study of gujranwala city

    International Nuclear Information System (INIS)

    Haydar, S.; Rashid, H.

    2016-01-01

    A study was conducted to evaluate the drinking water quality of Gujranwala city. Samples were collected from 16 locations including: 4 tube wells, 4 overhead reservoirs (OHR) and 8 house connections. Twelve physicochemical and two bacteriological parameters were tested, before and after monsoon and compared with National Standards for Drinking Water Quality (NSDWQ). The results demonstrated that most of the physicochemical parameters, except lead, nickle and chromium were within NSDWQ before and after monsoon. Bacteriological and heavy metal contamination was found before and after the monsoon. Possible reasons of contamination are: no disinfection, old and leaking water pipes, poor drainage during monsoon and possible cross connections between water and sewerage lines. It is recommended to practice disinfection, laying of water and sewerage pipes on opposite sides of streets and periodic water quality monitoring. (author)

  7. Groundwater infiltration, surface water inflow and sewerage exfiltration considering hydrodynamic conditions in sewer systems.

    Science.gov (United States)

    Karpf, Christian; Hoeft, Stefan; Scheffer, Claudia; Fuchs, Lothar; Krebs, Peter

    2011-01-01

    Sewer systems are closely interlinked with groundwater and surface water. Due to leaks and regular openings in the sewer system (e.g. combined sewer overflow structures with sometimes reverse pressure conditions), groundwater infiltration and surface water inflow as well as exfiltration of sewage take place and cannot be avoided. In the paper a new hydrodynamic sewer network modelling approach will be presented, which includes--besides precipitation--hydrographs of groundwater and surface water as essential boundary conditions. The concept of the modelling approach and the models to describe the infiltration, inflow and exfiltration fluxes are described. The model application to the sewerage system of the City of Dresden during a flood event with complex conditions shows that the processes of infiltration, exfiltration and surface water inflows can be described with a higher reliability and accuracy, showing that surface water inflow causes a pronounced system reaction. Further, according to the simulation results, a high sensitivity of exfiltration rates on the in-sewer water levels and a relatively low influence of the dynamic conditions on the infiltration rates were found.

  8. Space density and clustering properties of a new sample of emission-line galaxies

    International Nuclear Information System (INIS)

    Wasilewski, A.J.

    1982-01-01

    A moderate-dispersion objective-prism survey for low-redshift emission-line galaxies has been carried out in an 825 sq. deg. region of sky with the Burrell Schmidt telescope of Case Western Reserve University. A 4 0 prism (300 A/mm at H#betta#) was used with the Illa-J emulsion to show that a new sample of emission-line galaxies is available even in areas already searched with the excess uv-continuum technique. The new emission-line galaxies occur quite commonly in systems with peculiar morphology indicating gravitational interaction with a close companion or other disturbance. About 10 to 15% of the sample are Seyfert galaxies. It is suggested that tidal interaction involving matter infall play a significant role in the generation of an emission-line spectrum. The space density of the new galaxies is found to be similar to the space density of the Makarian galaxies. Like the Markarian sample, the galaxies in the present survey represent about 10% of all galaxies in the absolute magnitude range M/sub p/ = -16 to -22. The observations also indicate that current estimates of dwarf galaxy space densities may be too low. The clustering properties of the new galaxies have been investigated using two approaches: cluster contour maps and the spatial correlation function. These tests suggest that there is weak clustering and possibly superclustering within the sample itself and that the galaxies considered here are about as common in clusters of ordinary galaxies as in the field

  9. On-line determination of manganese in solid seafood samples by flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Yebra, M.C.; Moreno-Cid, A.

    2003-01-01

    Manganese is extracted on-line from solid seafood samples by a simple continuous ultrasound-assisted extraction system (CUES). This system is connected to an on-line manifold, which permits the flow-injection flame atomic absorption spectrometric determination of manganese. Optimisation of the continuous leaching procedure is performed by an experimental design. The proposed method allows the determination of manganese with a relative standard deviation of 0.9% for a sample containing 23.4 μg g -1 manganese (dry mass). The detection limit is 0.4 μg g -1 (dry mass) for 30 mg of sample and the sample throughput is ca. 60 samples per hour. Accurate results are obtained by measuring TORT-1 certified reference material. The procedure is finally applied to mussel, tuna, sardine and clams samples

  10. Performance of fully private and concessionary water and sewerage companies: a metafrontier approach.

    Science.gov (United States)

    Molinos-Senante, María; Sala-Garrido, Ramon

    2016-06-01

    As many countries have privatized their water industries, there is increasing interest in comparing the efficiency of public and private water and sewerage companies (WaSCs). However, previous studies have not considered that privatization can be carried out following two main approaches: fully private WaSCs, which involve the sale of utilities to the private sector, and concessionary WaSCs, in which only the operation of the services is privatized. This paper investigates, for the first time, the impact of both privatization approaches on the efficiency of WaSCs. In doing so, data envelopment analysis (DEA) was applied. However, unlike traditional models, the metafrontier concept was used in this research as it cannot be assumed that fully private and concessionary WaSCs share the same production frontier. The empirical application focused on the Chilean water industry as it was privatized from 1998 to 2004 following the two approaches described. The results suggest that the performance of fully private WaSCs is better than that of concessionary WaSCs. The conclusions of this study will be of great interest to water authorities worldwide facing the challenge of water industry privatization.

  11. A silicon photo-multiplier signal readout using strip-line and waveform sampling for Positron Emission Tomography

    Science.gov (United States)

    Kim, H.; Chen, C.-T.; Eclov, N.; Ronzhin, A.; Murat, P.; Ramberg, E.; Los, S.; Kao, C.-M.

    2016-09-01

    A strip-line and waveform sampling based readout is a signal multiplexing method that can efficiently reduce the readout channels while fully exploiting the fast time characteristics of photo-detectors such as the SiPM. We have applied this readout method for SiPM-based time-of-flight (TOF) positron emission tomography (PET) detectors. We have prototyped strip-line boards in which 8 SiPMs (pitch 5.2 mm) are connected by using a single strip-line, and the signals appearing at the ends of the strip-line are acquired by using the DRS4 waveform sampler at a nominal sampling frequency of 1-5 GS/s. Experimental tests using laser and LYSO scintillator are carried out to assess the performance of the strip-line board. Each SiPM position, which is inferred from the arrival time difference of the two signals at the ends of the strip-line, is well identified with 2.6 mm FWHM resolution when the SiPMs are coupled to LYSO crystals and irradiated by a 22Na source. The average energy and coincidence time resolution corresponding to 511 keV photons are measured to be ∼32% and ∼510 ps FWHM, respectively, at a 5.0 GS/s DRS4 sampling rate. The results show that the sampling rate can be lowered to 1.5 GS/s without performance degradation. These encouraging initial test results indicate that the strip-line and waveform sampling readout method is applicable for SiPM-based TOF PET development.

  12. Sampling and sample preparation development for analytical and on-line measurement techniques of process liquids; Naeytteenoton ja kaesittelyn kehittaeminen prosessinesteiden analytiikan ja on-line mittaustekniikan tarpeisiin - MPKT 11

    Energy Technology Data Exchange (ETDEWEB)

    Karttunen, K. [Oulu Univ. (Finland)

    1998-12-31

    Main goal of the research project is to develop sampling and sample handling methods and techniques for pulp and paper industry to be used for analysis and on-line purposes. The research focus specially on the research and development of the classification and separation methods and techniques needed for liquid and colloidal substances as well as in ion analysis. (orig.)

  13. Sampling and sample preparation development for analytical and on-line measurement techniques of process liquids; Naeytteenoton ja kaesittelyn kehittaeminen prosessinesteiden analytiikan ja on-line mittaustekniikan tarpeisiin - MPKT 11

    Energy Technology Data Exchange (ETDEWEB)

    Karttunen, K [Oulu Univ. (Finland)

    1999-12-31

    Main goal of the research project is to develop sampling and sample handling methods and techniques for pulp and paper industry to be used for analysis and on-line purposes. The research focus specially on the research and development of the classification and separation methods and techniques needed for liquid and colloidal substances as well as in ion analysis. (orig.)

  14. Design of modified annulus air sampling system for the detection of leakage in waste transfer line

    International Nuclear Information System (INIS)

    Deokar, U.V; Khot, A.R.; Mathew, P.; Ganesh, G.; Tripathi, R.M.; Srivastava, Srishti

    2018-01-01

    Various liquid waste streams are generated during the operation of reprocessing plant. The High Level (HL), Intermediate Level (IL) and Low Level (LL) liquid wastes generated, are transferred from reprocessing plant to Waste Management Facility. These respective waste streams are transferred through pipe-in-pipe lines along the shielded concrete trench. For detection of radioactive leakage from primary waste transfer line into secondary line, sampling of the annulus air between the two pipes is carried out. The currently installed pressurized annulus air sampling system did not have online leakage detection provision. Hence, there are chances of personal exposure and airborne activity in the working area. To overcome these design flaws, free air flow modified online annulus air sampling system with more safety features is designed

  15. Automated Sample Exchange Robots for the Structural Biology Beam Lines at the Photon Factory

    International Nuclear Information System (INIS)

    Hiraki, Masahiko; Watanabe, Shokei; Yamada, Yusuke; Matsugaki, Naohiro; Igarashi, Noriyuki; Gaponov, Yurii; Wakatsuki, Soichi

    2007-01-01

    We are now developing automated sample exchange robots for high-throughput protein crystallographic experiments for onsite use at synchrotron beam lines. It is part of the fully automated robotics systems being developed at the Photon Factory, for the purposes of protein crystallization, monitoring crystal growth, harvesting and freezing crystals, mounting the crystals inside a hutch and for data collection. We have already installed the sample exchange robots based on the SSRL automated mounting system at our insertion device beam lines BL-5A and AR-NW12A at the Photon Factory. In order to reduce the time required for sample exchange further, a prototype of a double-tonged system was developed. As a result of preliminary experiments with double-tonged robots, the sample exchange time was successfully reduced from 70 seconds to 10 seconds with the exception of the time required for pre-cooling and warming up the tongs

  16. Design flow factors for sewerage systems in small arid communities

    Directory of Open Access Journals (Sweden)

    Emad H. Imam

    2014-09-01

    Full Text Available Reliable estimation of sewage flow rates is essential for the proper design of sewers, pumping stations, and treatment plants. The design of the various components of the sewerage system should be based on the most critical flow rates with a focus on extremely low and peak flow rates that would be sustained for a duration related to the acceptable limits of behavior of the components under consideration. The extreme flow conditions and to what extent they differ from the average values are closely related to the size of the community or network, and the socioeconomic conditions. A single pumping station is usually sufficient to pump flow from small community in either flat or non-undulating topography. Therefore, the hydraulic loading on the wastewater treatment plant (WWTP results from the pumped flow from the pumping station rather than the trunk sewer flow. The intermittent operation of the pumping units further accentuates the sewage hydrograph in the final trunk sewer. Accordingly, the design flow for the various components of the WWTP should be determined based on their relevant flow factors. In this study, analysis of one representative small community out of five monitored small communities in Egypt and the Kingdom of Saudi Arabia is presented. Pumped sewage flow rates were measured and the sewer incoming flows were hydraulically derived. The hourly and daily sewer and pumped flow records were analyzed to derive the relationship between the flow factors that would be sustained for various durations (instantaneously, 1 h, 2 h, etc. and their probability of non-exceedance. The resulting peaking factors with a consideration for their sustained flow duration and specified probability would permit the design of the various components of the treatment plant using more accurate critical flows.

  17. Design flow factors for sewerage systems in small arid communities.

    Science.gov (United States)

    Imam, Emad H; Elnakar, Haitham Y

    2014-09-01

    Reliable estimation of sewage flow rates is essential for the proper design of sewers, pumping stations, and treatment plants. The design of the various components of the sewerage system should be based on the most critical flow rates with a focus on extremely low and peak flow rates that would be sustained for a duration related to the acceptable limits of behavior of the components under consideration. The extreme flow conditions and to what extent they differ from the average values are closely related to the size of the community or network, and the socioeconomic conditions. A single pumping station is usually sufficient to pump flow from small community in either flat or non-undulating topography. Therefore, the hydraulic loading on the wastewater treatment plant (WWTP) results from the pumped flow from the pumping station rather than the trunk sewer flow. The intermittent operation of the pumping units further accentuates the sewage hydrograph in the final trunk sewer. Accordingly, the design flow for the various components of the WWTP should be determined based on their relevant flow factors. In this study, analysis of one representative small community out of five monitored small communities in Egypt and the Kingdom of Saudi Arabia is presented. Pumped sewage flow rates were measured and the sewer incoming flows were hydraulically derived. The hourly and daily sewer and pumped flow records were analyzed to derive the relationship between the flow factors that would be sustained for various durations (instantaneously, 1 h, 2 h, etc.) and their probability of non-exceedance. The resulting peaking factors with a consideration for their sustained flow duration and specified probability would permit the design of the various components of the treatment plant using more accurate critical flows.

  18. The retention of iodine in stainless steel sample lines

    Energy Technology Data Exchange (ETDEWEB)

    Evans, G.J.; Deir, C. [Univ. of Toronto (Canada); Ball, J.M. [Whiteshell Laboratories, Pinawa (Canada)

    1995-02-01

    Following an accident in a multi-unit CANDU nuclear generating station, decontamination of air vented from containment would play a critical role in minimizing the release of iodine to the environment. The concentration of gas phase iodine in containment air would be measured using the post accident radiation monitoring system, requiring that air samples be passed through a considerable length of tubing to a remote location where the desired measurements could safely be made. A significant loss of iodine, due to adsorption on the sample line surfaces, could greatly distort the measurement. In this study, the retention of I{sub 2}(g) on stainless steel was evaluated in bench scale experiments in order to evaluate, and if possible minimise, the extent of any such line losses. Experiments at the University of Toronto were performed using 6 inch lengths of 1/4 inch stainless steel tubing. Air, containing I-131 labelled I{sub 2}(g), ranging in concentration from 10{sup {minus}10} to 10{sup {minus}6} mol/dm{sup 3} and relative humidity (:RH) from 20 to 90 %, was passed through tubing samples maintained at temperatures ranging from 25 to 90{degrees}C. Adsorption at low gas phase iodine concentrations differed substantially from that at higher concentrations. The rate of deposition was proportional to the gas phase concentration, giving support to the concept of a first order deposition velocity. The surface loading increased with increasing relative humidity, particularly at low RH values, while the deposition rate decreased with increasing temperature. Surface water on the steel may play an important role in the deposition process. The chemisorbed iodine was located primarily in areas of corrosion. Furthermore, water used to wash the steel contained Fe, Mn and iodine in the form of iodide, suggesting that I{sub 2} reacted to form metal iodides. The deposition of I{sub 2} was also found to depend on the initial surface condition.

  19. Uptake of Heavy Metal Residues from Sewerage Sludge in the Milk of Goat and Cattle during Summer Season

    Directory of Open Access Journals (Sweden)

    Bilal Aslam, Ijaz Javed*, Faqir Hussain Khan and Zia-ur-Rahman

    2011-01-01

    Full Text Available Uptake of different heavy metal residues including cadmium (Cd, chromium (Cr, nickel (Ni, led (Pb, arsenic (As, and mercury (Hg were determined in goat and cattle milk collected from two areas, each consisted of three sites. Area 1 was selected in the North-East and Area 2 in the North-West of Faisalabad city along the main sewerage drains. Levels of Cd, Cr, Ni, Pb, As and Hg in the milk of goat and cattle were higher than the most reported values in the literature. The levels of heavy metal residues in the milk of cattle from Area 1 were higher than those present in cattle milk from Area 2. However, in case of goat milk the residual values from Area 1 and Area 2 were non-significantly different. It was concluded that the levels of Cd, Cr, Ni, Pb, As and Hg in the milk of goat and cattle were higher than reported values in the literature.

  20. CORRELATION ANALYSIS OF A LARGE SAMPLE OF NARROW-LINE SEYFERT 1 GALAXIES: LINKING CENTRAL ENGINE AND HOST PROPERTIES

    International Nuclear Information System (INIS)

    Xu Dawei; Komossa, S.; Wang Jing; Yuan Weimin; Zhou Hongyan; Lu Honglin; Li Cheng; Grupe, Dirk

    2012-01-01

    We present a statistical study of a large, homogeneously analyzed sample of narrow-line Seyfert 1 (NLS1) galaxies, accompanied by a comparison sample of broad-line Seyfert 1 (BLS1) galaxies. Optical emission-line and continuum properties are subjected to correlation analyses, in order to identify the main drivers of the correlation space of active galactic nuclei (AGNs), and of NLS1 galaxies in particular. For the first time, we have established the density of the narrow-line region as a key parameter in Eigenvector 1 space, as important as the Eddington ratio L/L Edd . This is important because it links the properties of the central engine with the properties of the host galaxy, i.e., the interstellar medium (ISM). We also confirm previously found correlations involving the line width of Hβ and the strength of the Fe II and [O III] λ5007 emission lines, and we confirm the important role played by L/L Edd in driving the properties of NLS1 galaxies. A spatial correlation analysis shows that large-scale environments of the BLS1 and NLS1 galaxies of our sample are similar. If mergers are rare in our sample, accretion-driven winds, on the one hand, or bar-driven inflows, on the other hand, may account for the strong dependence of Eigenvector 1 on ISM density.

  1. Environmental radiation in Higashi-Hiroshima Campus, Hiroshima University

    International Nuclear Information System (INIS)

    Inada, K.; Matsuhima, A.; Nakashima, S.; Takahashi, Y.; Shizuma, K.; Saito, T.; Iwatani, K.

    2006-01-01

    Environmental radiation of the water sample from the junction point to public sewerage system and from Kadowaki Chosetsu Pond in Higashi-Hiroshima Campus, Hiroshima University was measured. Time dependence of the total radiation from β-emitter in 40 K equivalent was checked from 1995 to 2005. Seasonal dependence of the environmental radiation for the junction point to public sewerage system was observed. There was no relation between this seasonal dependence and the data of discharge of the effluent from Radioisotope Center, suggesting that there was no radiation originated from the RI facilities. The seasonal dependence was closely related to the weight of residue of the water sample. The present results show an interesting seasonal dependence of the weight of residue of the water sample from the junction point to public sewerage system. (author)

  2. 105-K east sandfilter backwash line sample analysis report: Third campaign

    International Nuclear Information System (INIS)

    Miller, G.L.; Bechtold, D.B.

    1996-01-01

    This project seeks to produce uranium (U) and plutonium (Pu) analyses of samples taken from the KE basin filter backwash line each time the sand filter is backwashed. K Basin operations will use the analytical results to determine additions of fissile materials to the backwash sludge pit and thereby maintain a running inventory of fissile elements in the pit. K Basin operations must not exceed a certain total inventory in order to be within a criticality specification. The third campaign of this project consisted of three samples, numbered by the customer 245KEB, 246KEB, and 247KEB. A revised letter of instruction controlled their processing

  3. Evaluation of different continuous cell lines in the isolation of mumps virus by the shell vial method from clinical samples

    Science.gov (United States)

    Reina, J; Ballesteros, F; Mari, M; Munar, M

    2001-01-01

    Aims—To compare prospectively the efficacy of the Vero, LLC-MK2, MDCK, Hep-2, and MRC-5 cell lines in the isolation of the mumps virus from clinical samples by means of the shell vial method. Methods—During an epidemic outbreak of parotiditis 48 clinical samples (saliva swabs and CSF) were studied. Two vials of the Vero, LLC-MK2, MDCK, MRC-5, and Hep-2 cell lines were inoculated with 0.2 ml of the samples by the shell vial assay. The vials were incubated at 36°C for two and five days. The vials were then fixed with acetone at -20°C for 10 minutes and stained by a monoclonal antibody against mumps virus by means of an indirect immunofluorescence assay. Results—The mumps virus was isolated from 36 samples. The Vero and LLC-MK2 cell lines showed a 100% isolation capacity, MDCK showed 77.7%, MRC-5 showed 44.4%, and Hep-2 showed 22.2%. The Vero and LLC-MK2 lines were significantly different to the other cell lines (p 5 infectious foci) were 94.4% for Vero, 97.2% for LLC-MK2, 5.5% for MDCK, 5.5% for Hep-2, and 0% for MRC-5. Conclusions—The Vero and LLC-MK2 cell lines are equally efficient at two and five days incubation for the isolation of the mumps virus from clinical samples, and the use of the shell vial method considerably shortens the time of aetiological diagnosis with higher specificity. Key Words: mumps virus • Vero cell line • LLC-MK2 cell line • MDCK cell line • Hep-2 cell line • MRC-5 cell line • isolation • shell vial PMID:11729211

  4. Integrated system technologies for water and sewage works. Information system technologies for rainwater drainage. Jogesuido sogo system gijutsu. Kou joho system

    Energy Technology Data Exchange (ETDEWEB)

    Shinohara, T; Nakada, M; Kondo, S [Toshiba Corp., Tokyo (Japan)

    1994-05-01

    The present report introduces the technological trend of rainwater drainage information system mainly with radar rain gauges. The information network must be strengthened as measures against the urban flood from the rainwater drainage. A radar rain gauge-based combination is needed of synthetic and organic processing technologies covering the traveling prediction of rainfall, data communication and rainwater drainage/flooding prediction. The correction method and data communication/display technology are explained for the measurement with radar rain gauges. In both correlation function method and rainfall area pursuit method, the traveling of rainfall is predicted by utilizing the radar information for the sewerage system. For the drainage analysis, it is necessary to quantitatively estimate the rainwater drained into both main and branch sewerage lines. It is made by preparing a rainwater drainage model. The quantitative estimation of rainwater drained into the branch sewerage lines calls for a revised Road Research Laboratory guidance by the Ministry of Construction. Supplemented with knowledge by veteran operators, the displayed image of pump operation support system is simulated for its verification. 2 refs., 3 figs.

  5. Biological water-quality assessment of selected streams in the Milwaukee Metropolitan Sewerage District Planning Area of Wisconsin, 2007

    Science.gov (United States)

    Scudder Eikenberry, Barbara C.; Bell, Amanda H.; Sullivan, Daniel J.; Lutz, Michelle A.; Alvarez, David A.

    2010-01-01

    Changes in the water quality of stream ecosystems in an urban area may manifest in conspicuous ways, such as in murky or smelly streamwater, or in less conspicuous ways, such as fewer native or pollution-sensitive organisms. In 2004, and again in 2007, the U.S. Geological Survey sampled stream organisms—algae, invertebrates, and fish—in 14 Milwaukee area streams to assess water quality as part of the ongoing Milwaukee Metropolitan Sewerage District (MMSD) Corridor Study. In addition, passive-sampling devices (SPMDs, “semipermeable membrane devices”) were deployed at a subset of sites in order to evaluate the potential exposure of stream organisms to certain toxic chemicals. Results of the 2007 sampling effort are the focus of this report. Results of sampling from 2007 are compared with results from 2004. The water quality of sampled streams was assessed by evaluating biological-assemblage data, metrics computed from assemblage data, and an aggregate bioassessment ranking method that combined data for algae, invertebrates, and fish. These data contain information about the abundance (number) of different species in each group of stream organisms and the balance between species that can or cannot tolerate polluted or disturbed conditions. In 2007, the highest numbers of algal, invertebrate, and fish species were found at the Milwaukee River at Milwaukee, the largest sampled site. Algal results indicated water quality concerns at 10 of the 14 sampled sites due to the occurrence of nuisance algae or low percentages of pollution-sensitive algae. When compared to 2004, total algal biovolume was higher in 2007 at 12 of 14 sites, due mostly to more nuisance green algae from unknown causes. Results of several metrics, including the Hilsenhoff Biotic Index (HBI-10), suggest that invertebrate assemblages in the Little Menomonee River, Underwood Creek, and Honey Creek were poorer quality in 2007 compared to 2004. Six sites received “very poor” quality ratings for

  6. Development of a New Microextraction Fiber Combined to On-Line Sample Stacking Capillary Electrophoresis UV Detection for Acidic Drugs Determination in Real Water Samples

    Science.gov (United States)

    Araujo, Lilia; Prieto, Avismelsi; Navalón, Alberto; Vílchez, José Luis; Valera, Paola; Zambrano, Ana; Dugas, Vincent

    2017-01-01

    A new analytical method coupling a (off-line) solid-phase microextraction with an on-line capillary electrophoresis (CE) sample enrichment technique was developed for the analysis of ketoprofen, naproxen and clofibric acid from water samples, which are known as contaminants of emerging concern in aquatic environments. New solid-phase microextraction fibers based on physical coupling of chromatographic supports onto epoxy glue coated needle were studied for the off-line preconcentration of these micropollutants. Identification and quantification of such acidic drugs were done by capillary zone electrophoresis (CZE) using ultraviolet diode array detection (DAD). Further enhancement of concentration sensitivity detection was achieved by on-line CE “acetonitrile stacking” preconcentration technique. Among the eight chromatographic supports investigated, Porapak Q sorbent showed higher extraction and preconcentration capacities. The screening of parameters that influence the microextraction process was carried out using a two-level fractional factorial. Optimization of the most relevant parameters was then done through a surface response three-factor Box-Behnken design. The limits of detection and limits of quantification for the three drugs ranged between 0.96 and 1.27 µg∙L−1 and 2.91 and 3.86 µg∙L−1, respectively. Recovery yields of approximately 95 to 104% were measured. The developed method is simple, precise, accurate, and allows quantification of residues of these micropollutants in Genil River water samples using inexpensive fibers. PMID:28686186

  7. Development of a New Microextraction Fiber Combined to On-Line Sample Stacking Capillary Electrophoresis UV Detection for Acidic Drugs Determination in Real Water Samples

    Directory of Open Access Journals (Sweden)

    Maria Espina-Benitez

    2017-07-01

    Full Text Available A new analytical method coupling a (off-line solid-phase microextraction with an on-line capillary electrophoresis (CE sample enrichment technique was developed for the analysis of ketoprofen, naproxen and clofibric acid from water samples, which are known as contaminants of emerging concern in aquatic environments. New solid-phase microextraction fibers based on physical coupling of chromatographic supports onto epoxy glue coated needle were studied for the off-line preconcentration of these micropollutants. Identification and quantification of such acidic drugs were done by capillary zone electrophoresis (CZE using ultraviolet diode array detection (DAD. Further enhancement of concentration sensitivity detection was achieved by on-line CE “acetonitrile stacking” preconcentration technique. Among the eight chromatographic supports investigated, Porapak Q sorbent showed higher extraction and preconcentration capacities. The screening of parameters that influence the microextraction process was carried out using a two-level fractional factorial. Optimization of the most relevant parameters was then done through a surface response three-factor Box-Behnken design. The limits of detection and limits of quantification for the three drugs ranged between 0.96 and 1.27 µg∙L−1 and 2.91 and 3.86 µg∙L−1, respectively. Recovery yields of approximately 95 to 104% were measured. The developed method is simple, precise, accurate, and allows quantification of residues of these micropollutants in Genil River water samples using inexpensive fibers.

  8. Development of a New Microextraction Fiber Combined to On-Line Sample Stacking Capillary Electrophoresis UV Detection for Acidic Drugs Determination in Real Water Samples.

    Science.gov (United States)

    Espina-Benitez, Maria; Araujo, Lilia; Prieto, Avismelsi; Navalón, Alberto; Vílchez, José Luis; Valera, Paola; Zambrano, Ana; Dugas, Vincent

    2017-07-07

    A new analytical method coupling a (off-line) solid-phase microextraction with an on-line capillary electrophoresis (CE) sample enrichment technique was developed for the analysis of ketoprofen, naproxen and clofibric acid from water samples, which are known as contaminants of emerging concern in aquatic environments. New solid-phase microextraction fibers based on physical coupling of chromatographic supports onto epoxy glue coated needle were studied for the off-line preconcentration of these micropollutants. Identification and quantification of such acidic drugs were done by capillary zone electrophoresis (CZE) using ultraviolet diode array detection (DAD). Further enhancement of concentration sensitivity detection was achieved by on-line CE "acetonitrile stacking" preconcentration technique. Among the eight chromatographic supports investigated, Porapak Q sorbent showed higher extraction and preconcentration capacities. The screening of parameters that influence the microextraction process was carried out using a two-level fractional factorial. Optimization of the most relevant parameters was then done through a surface response three-factor Box-Behnken design. The limits of detection and limits of quantification for the three drugs ranged between 0.96 and 1.27 µg∙L -1 and 2.91 and 3.86 µg∙L -1 , respectively. Recovery yields of approximately 95 to 104% were measured. The developed method is simple, precise, accurate, and allows quantification of residues of these micropollutants in Genil River water samples using inexpensive fibers.

  9. A feasibility study of a PET/MRI insert detector using strip-line and waveform sampling data acquisition.

    Science.gov (United States)

    Kim, H; Chen, C-T; Eclov, N; Ronzhin, A; Murat, P; Ramberg, E; Los, S; Wyrwicz, Alice M; Li, Limin; Kao, C-M

    2015-06-01

    We are developing a time-of-flight Positron Emission Tomography (PET) detector by using silicon photo-multipliers (SiPM) on a strip-line and high speed waveform sampling data acquisition. In this design, multiple SiPMs are connected on a single strip-line and signal waveforms on the strip-line are sampled at two ends of the strip to reduce readout channels while fully exploiting the fast time response of SiPMs. In addition to the deposited energy and time information, the position of the hit SiPM along the strip-line is determined by the arrival time difference of the waveform. Due to the insensitivity of the SiPMs to magnetic fields and the compact front-end electronics, the detector approach is highly attractive for developing a PET insert system for a magnetic resonance imaging (MRI) scanner to provide simultaneous PET/MR imaging. To investigate the feasibility, experimental tests using prototype detector modules have been conducted inside a 9.4 Tesla small animal MRI scanner (Bruker BioSpec 94/30 imaging spectrometer). On the prototype strip-line board, 16 SiPMs (5.2 mm pitch) are installed on two strip-lines and coupled to 2 × 8 LYSO scintillators (5.0 × 5.0 × 10.0 mm 3 with 5.2 mm pitch). The outputs of the strip-line boards are connected to a Domino-Ring-Sampler (DRS4) evaluation board for waveform sampling. Preliminary experimental results show that the effect of interference on the MRI image due to the PET detector is negligible and that PET detector performance is comparable with the results measured outside the MRI scanner.

  10. Mid-IR Properties of an Unbiased AGN Sample of the Local Universe. 1; Emission-Line Diagnostics

    Science.gov (United States)

    Weaver, K. A.; Melendez, M.; Muhotzky, R. F.; Kraemer, S.; Engle, K.; Malumuth. E.; Tueller, J.; Markwardt, C.; Berghea, C. T.; Dudik, R. P.; hide

    2010-01-01

    \\Ve compare mid-IR emission-lines properties, from high-resolution Spitzer IRS spectra of a statistically-complete hard X-ray (14-195 keV) selected sample of nearby (z < 0.05) AGN detected by the Burst Alert Telescope (BAT) aboard Swift. The luminosity distribution for the mid-infrared emission-lines, [O IV] 25.89 microns, [Ne II] 12.81 microns, [Ne III] 15.56 microns and [Ne V] 14.32 microns, and hard X-ray continuum show no differences between Seyfert 1 and Seyfert 2 populations, although six newly discovered BAT AGNs are shown to be under-luminous in [O IV], most likely the result of dust extinction in the host galaxy. The overall tightness of the mid-infrared correlations and BAT luminosities suggests that the emission lines primarily arise in gas ionized by the AGN. We also compared the mid-IR emission-lines in the BAT AGNs with those from published studies of star-forming galaxies and LINERs. We found that the BAT AGN fall into a distinctive region when comparing the [Ne III]/[Ne II] and the [O IV]/[Ne III] quantities. From this we found that sources that have been previously classified in the mid-infrared/optical as AGN have smaller emission line ratios than those found for the BAT AGNs, suggesting that, in our X-ray selected sample, the AGN represents the main contribution to the observed line emission. Overall, we present a different set of emission line diagnostics to distinguish between AGN and star forming galaxies that can be used as a tool to find new AGN.

  11. Sample size effect on the determination of the irreversibility line of high-Tc superconductors

    International Nuclear Information System (INIS)

    Li, Q.; Suenaga, M.; Li, Q.; Freltoft, T.

    1994-01-01

    The irreversibility lines of a high-J c superconducting Bi 2 Sr 2 Ca 2 Cu 3 O x /Ag tape were systematically measured upon a sequence of subdivisions of the sample. The irreversibility field H r (T) (parallel to the c axis) was found to change approximately as L 0.13 , where L is the effective dimension of the superconducting tape. Furthermore, it was found that the irreversibility line for a grain-aligned Bi 2 Sr 2 Ca 2 Cu 3 O x specimen can be approximately reproduced by the extrapolation of this relation down to a grain size of a few tens of micrometers. The observed size effect could significantly obscure the real physical meaning of the irreversibility lines. In addition, this finding surprisingly indicated that the Bi 2 Sr 2 Ca 2 Cu 2 O x /Ag tape and grain-aligned specimen may have similar flux line pinning strength

  12. Deciphering the Correlation between Breast Tumor Samples and Cell Lines by Integrating Copy Number Changes and Gene Expression Profiles

    Directory of Open Access Journals (Sweden)

    Yi Sun

    2015-01-01

    Full Text Available Breast cancer is one of the most common cancers with high incident rate and high mortality rate worldwide. Although different breast cancer cell lines were widely used in laboratory investigations, accumulated evidences have indicated that genomic differences exist between cancer cell lines and tissue samples in the past decades. The abundant molecular profiles of cancer cell lines and tumor samples deposited in the Cancer Cell Line Encyclopedia and The Cancer Genome Atlas now allow a systematical comparison of the breast cancer cell lines with breast tumors. We depicted the genomic characteristics of breast primary tumors based on the copy number variation and gene expression profiles and the breast cancer cell lines were compared to different subgroups of breast tumors. We identified that some of the breast cancer cell lines show high correlation with the tumor group that agrees with previous knowledge, while a big part of them do not, including the most used MCF7, MDA-MB-231, and T-47D. We presented a computational framework to identify cell lines that mostly resemble a certain tumor group for the breast tumor study. Our investigation presents a useful guide to bridge the gap between cell lines and tumors and helps to select the most suitable cell line models for personalized cancer studies.

  13. Validation of a Sampling Method to Collect Exposure Data for Central-Line-Associated Bloodstream Infections.

    Science.gov (United States)

    Hammami, Naïma; Mertens, Karl; Overholser, Rosanna; Goetghebeur, Els; Catry, Boudewijn; Lambert, Marie-Laurence

    2016-05-01

    Surveillance of central-line-associated bloodstream infections requires the labor-intensive counting of central-line days (CLDs). This workload could be reduced by sampling. Our objective was to evaluate the accuracy of various sampling strategies in the estimation of CLDs in intensive care units (ICUs) and to establish a set of rules to identify optimal sampling strategies depending on ICU characteristics. Analyses of existing data collected according to the European protocol for patient-based surveillance of ICU-acquired infections in Belgium between 2004 and 2012. CLD data were reported by 56 ICUs in 39 hospitals during 364 trimesters. We compared estimated CLD data obtained from weekly and monthly sampling schemes with the observed exhaustive CLD data over the trimester by assessing the CLD percentage error (ie, observed CLDs - estimated CLDs/observed CLDs). We identified predictors of improved accuracy using linear mixed models. When sampling once per week or 3 times per month, 80% of ICU trimesters had a CLD percentage error within 10%. When sampling twice per week, this was >90% of ICU trimesters. Sampling on Tuesdays provided the best estimations. In the linear mixed model, the observed CLD count was the best predictor for a smaller percentage error. The following sampling strategies provided an estimate within 10% of the actual CLD for 97% of the ICU trimesters with 90% confidence: 3 times per month in an ICU with >650 CLDs per trimester or each Tuesday in an ICU with >480 CLDs per trimester. Sampling of CLDs provides an acceptable alternative to daily collection of CLD data.

  14. On-line immunoaffinity column-liquid chromatography-tandem mass spectrometry method for trace analysis of diuron in wastewater treatment plant effluent sample.

    Science.gov (United States)

    Zhang, Xiuli; Martens, Dieter; Krämer, Petra M; Kettrup, Antonius A; Liang, Xinmiao

    2006-11-10

    An on-line immunoaffinity column with liquid chromatography/tandem mass spectrometry (IAC-LC-MS/MS) method for the determination of diuron in water matrices was described. This method used a sol-gel immunoaffinity column (20 mm x 4 mm I.D.) for on-line sample cleanup and enrichment, a monolithic analytical column (100 mm x 4.6 mm I.D.) for separation, and a triple quadrupole mass spectrometer for quantitation. The major challenges for the on-line set-up were discussed. The optimized on-line protocol was emphasized by the fact that low limit of quantitation (LOQ) of 1.0 ng/L was achieved with only 2.5-mL sample. In addition, a satisfactory accuracy ( approximately 90% of recovery) and precision (effect, the on-line IAC-LC-MS/MS analysis method can reliably determine diuron in wastewater treatment plant effluent sample.

  15. Relative humidity effects on water vapour fluxes measured with closed-path eddy-covariance systems with short sampling lines

    DEFF Research Database (Denmark)

    Fratini, Gerardo; Ibrom, Andreas; Arriga, Nicola

    2012-01-01

    It has been formerly recognised that increasing relative humidity in the sampling line of closed-path eddy-covariance systems leads to increasing attenuation of water vapour turbulent fluctuations, resulting in strong latent heat flux losses. This occurrence has been analyzed for very long (50 m...... from eddy-covariance systems featuring short (4 m) and very short (1 m) sampling lines running at the same clover field and show that relative humidity effects persist also for these setups, and should not be neglected. Starting from the work of Ibrom and co-workers, we propose a mixed method...... and correction method proposed here is deemed applicable to closed-path systems featuring a broad range of sampling lines, and indeed applicable also to passive gases as a special case. The methods described in this paper are incorporated, as processing options, in the free and open-source eddy...

  16. A system for on-line monitoring of light element concentration distributions in thin samples

    NARCIS (Netherlands)

    Brands, P.J.M.; Mutsaers, P.H.A.; Voigt, de M.J.A.

    1999-01-01

    At the Cyclotron Laboratory, a scanning proton microprobe is used to determine concentration distributions in biomedical samples. The data acquired in these measurements used to be analysed in a time consuming off-line analysis. To avoid the loss of valuable measurement and analysis time, DYANA was

  17. THE IMPACT OF FOOD WASTE DISCHARGE INTO THE MUNICIPAL SEWERAGE ON COD CONCENTRATION IN URBAN WASTEWATER IN OLSZTYN

    Directory of Open Access Journals (Sweden)

    Wojciech Janczukowicz

    2016-05-01

    Full Text Available The operators of wastewater treatment plants in Poland have been observing an increase in the concentration of raw sewage for several years. In particular for organic substances. This is the effect of water consumption reduction, restoration of the sewerage networks, growing wealth, widespread waste of food. The most serious adverse, influencing on the municipal wastewater composition is colloid mills application in gastronomical objects and the discharge of shredded food waste to sewer. That widespread behavior has been noticed and negated, in 2010 year, by the common position of GIS and the ME. Far too late, which confirms the situation observed at the Olsztyn wastewater treatment plant, where the biggest increase of COD values ​​was observed in 2008–2010. The average concentration of COD of sewage in the period 2011–2014 was almost twice higher than in 1996, real PE is close to the design value, despite the fact that the hydraulic load of the object slightly exceeded 50% of design value. Removing such large organic pollutant loads generates high costs, that could be avoided by reasonable food waste management.

  18. Hidden Broad Line Seyfert 2 Galaxies in the CfA and 12micron Samples

    OpenAIRE

    Tran, Hien D.

    2001-01-01

    We report the results of a spectropolarimetric survey of the CfA and 12micron samples of Seyfert 2 galaxies (S2s). Polarized (hidden) broad line regions (HBLRs) are confirmed in a number of galaxies, and several new cases (F02581-1136, MCG -3-58-7, NGC 5995, NGC 6552, NGC 7682) are reported. The 12micron S2 sample shows a significantly higher incidence of HBLR (50%) than its CfA counterpart (30%), suggesting that the latter may be incomplete in hidden AGNs. Compared to the non-HBLR S2s, the H...

  19. True coincidence summing correction determination for 214Bi principal gamma lines in NORM samples

    International Nuclear Information System (INIS)

    Haddad, Kh.

    2014-01-01

    The gamma lines 609.3 and 1,120.3 keV are two of the most intensive γ emissions of 214 Bi, but they have serious true coincidence summing (TCS) effects due to the complex decay schemes with multi-cascading transitions. TCS effects cause inaccurate count rate and hence erroneous results. A simple and easy experimental method for determination of TCS correction of 214 Bi gamma lines was developed in this work using naturally occurring radioactive material samples. Height efficiency and self attenuation corrections were determined as well. The developed method has been formulated theoretically and validated experimentally. The corrections problems were solved simply with neither additional standard source nor simulation skills. (author)

  20. On-line combination of liquid chromatography and capillary gas chromatography : preconcentration and analysis of organic compounds in aqueous samples

    NARCIS (Netherlands)

    Noij, T.H.M.; Weiss, E.; Herps, T.; Cruchten, van H.; Rijks, J.A.

    1988-01-01

    This paper describes the design of a new, versatile, and low-cost on-line LC-GC interface that allows the fast and reliable introduction of large sample volumes onto a capillary GC column. The sample introduction procedure consists successively of: evaporation of the entire sample (LC fraction),

  1. Drinking water quality of Sukkur municipal corporation

    International Nuclear Information System (INIS)

    Kandhar, I.A.; Ansari, A.K.

    2002-01-01

    SMC (Sukkur Municipal Corporation) supply the (filtered/settled) water for domestic purpose to the consumers, through intermittent water supply, from Phases I to IV. The water supply distribution network is underground and at most places pass parallel to sewerage lines. The grab sampling technique was followed for collecting representative samples. The official US-EPA and standard methods of water analysis have been used for drinking water quality analysis. DR/2000 spectrophotometer has been used for monitoring: Nitrates, Fluorides, Sulfates, Copper, Chromium, Iron and manganese. The trace metals Cr/sup 6/, Fe/sup 2+/ and other contaminants like; Turbidity and TSS (Total Suspended Solids) have been found higher than World Health Organization (WHO-1993) guideline values. (author)

  2. A system for on-line monitoring of light element concentration distributions in thin samples

    Energy Technology Data Exchange (ETDEWEB)

    Brands, P.J.M. E-mail: p.j.m.brands@tue.nl; Mutsaers, P.H.A.; Voigt, M.J.A. de

    1999-09-02

    At the Cyclotron Laboratory, a scanning proton microprobe is used to determine concentration distributions in biomedical samples. The data acquired in these measurements used to be analysed in a time consuming off-line analysis. To avoid the loss of valuable measurement and analysis time, DYANA was developed. DYANA is an on-line method for the analysis of data from biomedical measurements. By using a database of background shapes, light elements such as Na and Mg, can be fitted even more precisely than in conventional fitting procedures. The entire analysis takes only several seconds and is performed while the acquisition system is gathering a new subset of data. Data acquisition must be guaranteed and may not be interfered by other parallel processes. Therefore, the analysis, the data acquisition and the experiment control is performed on a PCI-based Pentium personal computer (PC), running a real-time operating system. A second PC is added to run a graphical user interface for interaction with the experimenter and the monitoring of the analysed results. The system is here illustrated using atherosclerotic tissue but is applicable to all kinds of thin samples.

  3. Automatic data acquisition and on-line analysis of trace element concentration in serum samples

    International Nuclear Information System (INIS)

    Lecomte, R.; Paradis, P.; Monaro, S.

    1978-01-01

    A completely automated system has been developed to determine the trace element concentration in biological samples by measuring charged particle induced X-rays. A CDC-3100 computer with ADC and CAMAC interface is employed to control the data collection apparatus, acquire data and perform simultaneously the analysis. The experimental set-up consists of a large square plexiglass chamber in which a commercially available 750H Kodak Carousel is suitably arranged as a computer controlled sample changer. A method of extracting trace element concentrations using reference spectra is presented and an on-line program has been developed to easily and conveniently obtain final results at the end of each run. (Auth.)

  4. Sewerage Collection Lines - MO 2014 Springfield Sewer Dead Points (SHP)

    Data.gov (United States)

    NSGIC State | GIS Inventory — This data set was prepared for the City of Springfield by the GIS Section of the Information Systems Department. This is a point file that shows manholes, lampholes,...

  5. THE CORES OF THE Fe Kα LINES IN ACTIVE GALACTIC NUCLEI: AN EXTENDED CHANDRA HIGH ENERGY GRATING SAMPLE

    International Nuclear Information System (INIS)

    Shu, X. W.; Wang, J. X.; Yaqoob, T.

    2010-01-01

    We extend the study of the core of the Fe Kα emission line at ∼6.4 keV in Seyfert galaxies reported by Yaqoob and Padmanabhan using a larger sample observed by the Chandra high-energy grating (HEG). The sample consists of 82 observations of 36 unique sources with z H 23 cm -2 ) Seyfert galaxies to date. From an empirical and uniform analysis, we present measurements of the Fe Kα line centroid energy, flux, equivalent width (EW), and intrinsic width (FWHM). The Fe Kα line is detected in 33 sources, and its centroid energy is constrained in 32 sources. In 27 sources, the statistical quality of the data is good enough to yield measurements of the FWHM. We find that the distribution in the line centroid energy is strongly peaked around the value for neutral Fe, with over 80% of the observations giving values in the range 6.38-6.43 keV. Including statistical errors, 30 out of 32 sources (∼94%) have a line centroid energy in the range 6.35-6.47 keV. The mean EW, among the observations in which a non-zero lower limit could be measured, was 53 ± 3 eV. The mean FWHM from the subsample of 27 sources was 2060 ± 230 km s -1 . The mean EW and FWHM are somewhat higher when multiple observations for a given source are averaged. From a comparison with the Hβ optical emission-line widths (or, for one source, Brα), we find that there is no universal location of the Fe Kα line-emitting region relative to the optical broad-line region (BLR). In general, a given source may have contributions to the Fe Kα line flux from parsec-scale distances from the putative black hole, down to matter a factor ∼2 closer to the black hole than the BLR. We confirm the presence of the X-ray Baldwin effect, an anti-correlation between the Fe Kα line EW and X-ray continuum luminosity. The HEG data have enabled isolation of this effect to the narrow core of the Fe Kα line.

  6. MID-INFRARED PROPERTIES OF THE SWIFT BURST ALERT TELESCOPE ACTIVE GALACTIC NUCLEI SAMPLE OF THE LOCAL UNIVERSE. I. EMISSION-LINE DIAGNOSTICS

    International Nuclear Information System (INIS)

    Weaver, K. A.; Melendez, M.; Mushotzky, R. F.; Kraemer, S.; Engle, K.; Malumuth, E.; Tueller, J.; Markwardt, C.; Berghea, C. T.; Dudik, R. P.; Winter, L. M.; Armus, L.

    2010-01-01

    We compare mid-infrared emission-line properties from high-resolution Spitzer spectra of a hard X-ray (14-195 keV) selected sample of nearby (z < 0.05) active galactic nuclei (AGNs) detected by the Burst Alert Telescope (BAT) aboard Swift. The luminosity distribution for the mid-infrared emission lines, [O IV] 25.89 μm, [Ne II] 12.81 μm, [Ne III] 15.56 μm, and [Ne V] 14.32/24.32 μm, and hard X-ray continuum show no differences between Seyfert 1 and Seyfert 2 populations; however, six newly discovered BAT AGNs are under-luminous in [O IV], most likely the result of dust extinction in the host galaxy. The overall tightness of the mid-infrared correlations and BAT fluxes and luminosities suggests that the emission lines primarily arise in gas ionized by the AGNs. We also compare the mid-infrared emission lines in the BAT AGNs with those from published studies of ULIRGs, Palomar-Green quasars, star-forming galaxies, and LINERs. We find that the BAT AGN sample falls into a distinctive region when comparing the [Ne III]/[Ne II] and the [O IV]/[Ne III] ratios. These line ratios are lower in sources that have been previously classified in the mid-infrared/optical as AGNs than those found for the BAT AGNs, suggesting that, in our X-ray selected sample, the AGNs represent the main contribution to the observed line emission. These ratios represent a new emission line diagnostic for distinguishing between AGNs and star-forming galaxies.

  7. The Kinematics of the Permitted C ii λ 6578 Line in a Large Sample of Planetary Nebulae

    Energy Technology Data Exchange (ETDEWEB)

    Richer, Michael G.; Suárez, Genaro; López, José Alberto; García Díaz, María Teresa, E-mail: richer@astrosen.unam.mx, E-mail: gsuarez@astro.unam.mx, E-mail: jal@astrosen.unam.mx, E-mail: tere@astro.unam.mx [Instituto de Astronomía, Universidad Nacional Autónoma de México, Ensenada, Baja California (Mexico)

    2017-03-01

    We present spectroscopic observations of the C ii λ 6578 permitted line for 83 lines of sight in 76 planetary nebulae at high spectral resolution, most of them obtained with the Manchester Echelle Spectrograph on the 2.1 m telescope at the Observatorio Astronómico Nacional on the Sierra San Pedro Mártir. We study the kinematics of the C ii λ 6578 permitted line with respect to other permitted and collisionally excited lines. Statistically, we find that the kinematics of the C ii λ 6578 line are not those expected if this line arises from the recombination of C{sup 2+} ions or the fluorescence of C{sup +} ions in ionization equilibrium in a chemically homogeneous nebular plasma, but instead its kinematics are those appropriate for a volume more internal than expected. The planetary nebulae in this sample have well-defined morphology and are restricted to a limited range in H α line widths (no large values) compared to their counterparts in the Milky Way bulge; both these features could be interpreted as the result of young nebular shells, an inference that is also supported by nebular modeling. Concerning the long-standing discrepancy between chemical abundances inferred from permitted and collisionally excited emission lines in photoionized nebulae, our results imply that multiple plasma components occur commonly in planetary nebulae.

  8. Improving off-line accelerated tryptic digestion. Towards fast-lane proteolysis of complex biological samples.

    Science.gov (United States)

    Vukovic, Jadranka; Loftheim, Håvard; Winther, Bjørn; Reubsaet, J Léon E

    2008-06-27

    Off-line digestion of proteins using immobilized trypsin beads is studied with respect to the format of the digestion reactor, the digestion conditions, the comparison with in-solution digestion and its use in complex biological samples. The use of the filter vial as the most appropriate digestion reactor enables simple, efficient and easy-to-handle off-line digestion of the proteins on trypsin beads. It was shown that complex proteins like bovine serum albumin (BSA) need much longer time (89 min) and elevated temperature (37 degrees C) to be digested to an acceptable level compared to smaller proteins like cytochrome c (5 min, room temperature). Comparing the BSA digestion using immobilized trypsin beads with conventional in-solution digestion (overnight at 37 degrees C), it was shown that comparable results were obtained with respect to sequence coverage (>90%) and amount of missed cleavages (in both cases around 20 peptides with 1 or 2 missed cleavages were detected). However, the digestion using immobilized trypsin beads was considerable less time consuming. Good reproducibility and signal intensities were obtained for the digestion products of BSA in a complex urine sample. In addition to this, peptide products of proteins typically present in urine were identified.

  9. Trends and perspectives of flow injection/sequential injection on-line sample-pretreatment schemes coupled to ETAAS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2005-01-01

    Flow injection (FI) analysis, the first generation of this technique, became in the 1990s supplemented by its second generation, sequential injection (SI), and most recently by the third generation (i.e.,Lab-on-Valve). The dominant role played by FI in automatic, on-line, sample pretreatments in ...

  10. ECOLO-HOUSE in the heavy snow-fall region. Purification of sewerage water; Yukiguni ekoro house. Gesui shorisui no joka

    Energy Technology Data Exchange (ETDEWEB)

    Umemiya, H; Kitamura, K [Yamagata University, Yamagata (Japan)

    1997-11-25

    In a local town like Yonezawa city, a large city type sewerage system has not yet been spread. Most houses use septic tanks treating waste water from both toilet and kitchen/bath. The treated water from them is discharged directly into surface water of side ditches, etc., which produces environmental problems such as water pollution and eutrophication. Enhancement of purification effects was studied by putting walnut charcoal and bacilli into the aeration tank circulating air in the septic tank to secure bacteria and improve work of them in the aeration tank. The treated water is further reused as drinking water using peat layer. Walnut charcoal can be a nest of bacteria. By this, it became possible to cope also with environmental changes such as water quality and temperature in the septic tank. It is possible to always keep water quality in the purifying tank and quality of the treated water in a stabilized condition. Moreover, existence of bacteria can be confirmed even inside the pores of walnut charcoal can be confirmed. Porosity of walnut charcoal is made use of, and it is useful to use walnut charcoal as a nest of bacteria in the septic tank. 5 refs., 12 figs.

  11. Determination of cobalt in biological samples by line-source and high-resolution continuum source graphite furnace atomic absorption spectrometry using solid sampling or alkaline treatment

    International Nuclear Information System (INIS)

    Ribeiro, Anderson Schwingel; Vieira, Mariana Antunes; Furtado da Silva, Alessandra; Borges, Daniel L. Gallindo; Welz, Bernhard; Heitmann, Uwe; Curtius, Adilson Jose

    2005-01-01

    Two procedures for the determination of Co in biological samples by graphite furnace atomic absorption spectrometry (GF AAS) were compared: solid sampling (SS) and alkaline treatment with tetramethylammonium hydroxide (TMAH) using two different instruments for the investigation: a conventional line-source (LS) atomic absorption spectrometer and a prototype high-resolution continuum source atomic absorption spectrometer. For the direct introduction of the solid samples, certified reference materials (CRM) were ground to a particle size ≤50 μm. Alkaline treatment was carried out by placing about 250 mg of the sample in polypropylene flasks, adding 2 mL of 25% m/v tetramethylammonium hydroxide and de-ionized water. Due to its unique capacity of providing a 3-D spectral plot, a high-resolution continuum source (HR-CS) graphite furnace atomic absorption spectrometry was used as a tool to evaluate potential spectral interferences, including background absorption for both sample introduction procedures, revealing that a continuous background preceded the atomic signal for pyrolysis temperatures lower than 700 deg. C. Molecular absorption bands with pronounced rotational fine structure appeared for atomization temperatures >1800 deg. C probably as a consequence of the formation of PO. After optimization had been carried out using high resolution continuum source atomic absorption spectrometry, the optimized conditions were adopted also for line-source atomic absorption spectrometry. Six biological certified reference materials were analyzed, with calibration against aqueous standards, resulting in agreement with the certified values (according to the t-test for a 95% confidence level) and in detection limits as low as 5 ng g -1

  12. Evaluating the accuracy of sampling to estimate central line-days: simplification of the National Healthcare Safety Network surveillance methods.

    Science.gov (United States)

    Thompson, Nicola D; Edwards, Jonathan R; Bamberg, Wendy; Beldavs, Zintars G; Dumyati, Ghinwa; Godine, Deborah; Maloney, Meghan; Kainer, Marion; Ray, Susan; Thompson, Deborah; Wilson, Lucy; Magill, Shelley S

    2013-03-01

    To evaluate the accuracy of weekly sampling of central line-associated bloodstream infection (CLABSI) denominator data to estimate central line-days (CLDs). Obtained CLABSI denominator logs showing daily counts of patient-days and CLD for 6-12 consecutive months from participants and CLABSI numerators and facility and location characteristics from the National Healthcare Safety Network (NHSN). Convenience sample of 119 inpatient locations in 63 acute care facilities within 9 states participating in the Emerging Infections Program. Actual CLD and estimated CLD obtained from sampling denominator data on all single-day and 2-day (day-pair) samples were compared by assessing the distributions of the CLD percentage error. Facility and location characteristics associated with increased precision of estimated CLD were assessed. The impact of using estimated CLD to calculate CLABSI rates was evaluated by measuring the change in CLABSI decile ranking. The distribution of CLD percentage error varied by the day and number of days sampled. On average, day-pair samples provided more accurate estimates than did single-day samples. For several day-pair samples, approximately 90% of locations had CLD percentage error of less than or equal to ±5%. A lower number of CLD per month was most significantly associated with poor precision in estimated CLD. Most locations experienced no change in CLABSI decile ranking, and no location's CLABSI ranking changed by more than 2 deciles. Sampling to obtain estimated CLD is a valid alternative to daily data collection for a large proportion of locations. Development of a sampling guideline for NHSN users is underway.

  13. Noninvasive Sampling of Mucosal Lining Fluid for the Quantification of In Vivo Upper Airway Immune-mediator Levels

    DEFF Research Database (Denmark)

    Wolsk, Helene Mygind; Chawes, Bo L.; Thorsen, Jonathan

    2017-01-01

    (often used by other techniques). The mucosal lining fluid is sampled on a strip of filter paper placed at the anterior part of the inferior turbinate and left for 2 min of absorption. Analytes are eluted from the filter papers, and the extracted protein-based eluates are analyzed...

  14. Analysis of plant hormones by microemulsion electrokinetic capillary chromatography coupled with on-line large volume sample stacking.

    Science.gov (United States)

    Chen, Zongbao; Lin, Zian; Zhang, Lin; Cai, Yan; Zhang, Lan

    2012-04-07

    A novel method of microemulsion electrokinetic capillary chromatography (MEEKC) coupled with on-line large volume sample stacking was developed for the analysis of six plant hormones including indole-3-acetic acid, indole-3-butyric acid, indole-3-propionic acid, 1-naphthaleneacetic acid, abscisic acid and salicylic acid. Baseline separation of six plant hormones was achieved within 10 min by using the microemulsion background electrolyte containing a 97.2% (w/w) 10 mM borate buffer at pH 9.2, 1.0% (w/w) ethyl acetate as oil droplets, 0.6% (w/w) sodium dodecyl sulphate as surfactant and 1.2% (w/w) 1-butanol as cosurfactant. In addition, an on-line concentration method based on a large volume sample stacking technique and multiple wavelength detection was adopted for improving the detection sensitivity in order to determine trace level hormones in a real sample. The optimal method provided about 50-100 fold increase in detection sensitivity compared with a single MEEKC method, and the detection limits (S/N = 3) were between 0.005 and 0.02 μg mL(-1). The proposed method was simple, rapid and sensitive and could be applied to the determination of six plant hormones in spiked water samples, tobacco leaves and 1-naphthylacetic acid in leaf fertilizer. The recoveries ranged from 76.0% to 119.1%, and good reproducibilities were obtained with relative standard deviations (RSDs) less than 6.6%.

  15. [Hydrology and water quality of rainfall-runoff in combined sewerage system along Suzhou Creek in central Shanghai].

    Science.gov (United States)

    Cheng, Jiang; Yang, Kai; Huang, Xiao-Fang; Lü, Yong-Peng

    2009-07-15

    In order to obtain the processes of hydrology and water quality of urban combined sewerage system (CSS) in highly urbanized region, the precipitation, discharge and pollutant concentration of four different intensity rainfall (light rain, moderate rain, heavy rain and storm) were measured from Jul. to Sep. 2007 in the Chendulu CSS along Suzhou Creek in Shanghai. The results show that the shapes of runoff graph are similar to rainfall graph, with a weaker fluctuation range and a 15-25 min delay between rainfall and runoff graph. Runoff coefficients of the four different rainfall are 0.33, 0.62, 0.67 and 0.73, respectively. The 30/30 first flush phenomenon is found in Chendulu CSS. The peak of pollutant concentration graph lags rainfall peak about 30-40 min. The pH and event mean concentration (EMC) of Cu, Zn, Cr, Cd, Pb and Ni totally measure up to environmental quality standards V for surface water of China besides COD, BOD5, NH4(+) -N and TP, and the EMC of COD, BOD5, NH4(+) -N and TP are 225.0-544.1, 31.5-98.9, 8.9-44.2 and 1.98-3.52 mg x L(-1), respectively. The rainfall-runoff pollutant concentration in Chendulu CSS is close to those of other foreign cites. At the confidence level of p < 0.01, good relationships exist between SS and COD, BOD5, NH4(+) -N and TP, respectively, and the average proportion of particulate organic pollutant and nutrient is 70.21%.

  16. Multiple Lines of Evidence

    Energy Technology Data Exchange (ETDEWEB)

    Amidan, Brett G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Venzin, Alexander M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bramer, Lisa M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-06-03

    This paper discusses the process of identifying factors that influence the contamination level of a given decision area and then determining the likelihood that the area remains unacceptable. This process is referred to as lines of evidence. These lines of evidence then serve as inputs for the stratified compliance sampling (SCS) method, which requires a decision area to be divided into strata based upon contamination expectations. This is done in order to focus sampling efforts more within stratum where contamination is more likely and to use the domain knowledge about these likelihoods of the stratum remaining unacceptable to buy down the number of samples necessary, if possible. Two different building scenarios were considered as an example (see Table 3.1). SME expertise was elicited concerning four lines of evidence factors (see Table 3.2): 1) amount of contamination that was seen before decontamination, 2) post-decontamination air sampling information, 3) the applied decontaminant information, and 4) the surface material. Statistical experimental design and logistic regression modelling were used to help determine the likelihood that example stratum remained unacceptable for a given example scenario. The number of samples necessary for clearance was calculated by applying the SCS method to the example scenario, using the estimated likelihood of each stratum remaining unacceptable as was determined using the lines of evidence approach. The commonly used simple random sampling (SRS) method was also used to calculate the number of samples necessary for clearance for comparison purposes. The lines of evidence with SCS approach resulted in a 19% to 43% reduction in total number of samples necessary for clearance (see Table 3.6). The reduction depended upon the building scenario, as well as the level of percent clean criteria. A sensitivity analysis was also performed showing how changing the estimated likelihoods of stratum remaining unacceptable affect the number

  17. Samples and Sampling Protocols for Scientific Investigations | Joel ...

    African Journals Online (AJOL)

    ... from sampling, through sample preparation, calibration to final measurement and reporting. This paper, therefore offers useful information on practical guidance on sampling protocols in line with best practice and international standards. Keywords: Sampling, sampling protocols, chain of custody, analysis, documentation ...

  18. A large sample of Kohonen-selected SDSS quasars with weak emission lines: selection effects and statistical properties

    Science.gov (United States)

    Meusinger, H.; Balafkan, N.

    2014-08-01

    Aims: A tiny fraction of the quasar population shows remarkably weak emission lines. Several hypotheses have been developed, but the weak line quasar (WLQ) phenomenon still remains puzzling. The aim of this study was to create a sizeable sample of WLQs and WLQ-like objects and to evaluate various properties of this sample. Methods: We performed a search for WLQs in the spectroscopic data from the Sloan Digital Sky Survey Data Release 7 based on Kohonen self-organising maps for nearly 105 quasar spectra. The final sample consists of 365 quasars in the redshift range z = 0.6 - 4.2 (z¯ = 1.50 ± 0.45) and includes in particular a subsample of 46 WLQs with equivalent widths WMg iiattention was paid to selection effects. Results: The WLQs have, on average, significantly higher luminosities, Eddington ratios, and accretion rates. About half of the excess comes from a selection bias, but an intrinsic excess remains probably caused primarily by higher accretion rates. The spectral energy distribution shows a bluer continuum at rest-frame wavelengths ≳1500 Å. The variability in the optical and UV is relatively low, even taking the variability-luminosity anti-correlation into account. The percentage of radio detected quasars and of core-dominant radio sources is significantly higher than for the control sample, whereas the mean radio-loudness is lower. Conclusions: The properties of our WLQ sample can be consistently understood assuming that it consists of a mix of quasars at the beginning of a stage of increased accretion activity and of beamed radio-quiet quasars. The higher luminosities and Eddington ratios in combination with a bluer spectral energy distribution can be explained by hotter continua, i.e. higher accretion rates. If quasar activity consists of subphases with different accretion rates, a change towards a higher rate is probably accompanied by an only slow development of the broad line region. The composite WLQ spectrum can be reasonably matched by the

  19. Monitoring of an esterification reaction by on-line direct liquid sampling mass spectrometry and in-line mid infrared spectrometry with an attenuated total reflectance probe

    International Nuclear Information System (INIS)

    Owen, Andrew W.; McAulay, Edith A.J.; Nordon, Alison; Littlejohn, David; Lynch, Thomas P.; Lancaster, J. Steven; Wright, Robert G.

    2014-01-01

    Highlights: • High efficiency thermal vaporiser designed and used for on-line reaction monitoring. • Concentration profiles of all reactants and products obtained from mass spectra. • By-product formed from the presence of an impurity detected by MS but not MIR. • Mass spectrometry can detect trace and bulk components unlike molecular spectrometry. - Abstract: A specially designed thermal vaporiser was used with a process mass spectrometer designed for gas analysis to monitor the esterification of butan-1-ol and acetic anhydride. The reaction was conducted at two scales: in a 150 mL flask and a 1 L jacketed batch reactor, with liquid delivery flow rates to the vaporiser of 0.1 and 1.0 mL min −1 , respectively. Mass spectrometry measurements were made at selected ion masses, and classical least squares multivariate linear regression was used to produce concentration profiles for the reactants, products and catalyst. The extent of reaction was obtained from the butyl acetate profile and found to be 83% and 76% at 40 °C and 20 °C, respectively, at the 1 L scale. Reactions in the 1 L reactor were also monitored by in-line mid-infrared (MIR) spectrometry; off-line gas chromatography (GC) was used as a reference technique when building partial least squares (PLS) multivariate calibration models for prediction of butyl acetate concentrations from the MIR spectra. In validation experiments, good agreement was achieved between the concentration of butyl acetate obtained from in-line MIR spectra and off-line GC. In the initial few minutes of the reaction the profiles for butyl acetate derived from on-line direct liquid sampling mass spectrometry (DLSMS) differed from those of in-line MIR spectrometry owing to the 2 min transfer time between the reactor and mass spectrometer. As the reaction proceeded, however, the difference between the concentration profiles became less noticeable. DLSMS had advantages over in-line MIR spectrometry as it was easier to generate

  20. Authentication of M14 melanoma cell line proves misidentification of MDA‐MB‐435 breast cancer cell line

    Science.gov (United States)

    Korch, Christopher; Hall, Erin M.; Dirks, Wilhelm G.; Ewing, Margaret; Faries, Mark; Varella‐Garcia, Marileila; Robinson, Steven; Storts, Douglas; Turner, Jacqueline A.; Wang, Ying; Burnett, Edward C.; Healy, Lyn; Kniss, Douglas; Neve, Richard M.; Nims, Raymond W.; Reid, Yvonne A.; Robinson, William A.

    2017-01-01

    A variety of analytical approaches have indicated that melanoma cell line UCLA‐SO‐M14 (M14) and breast carcinoma cell line MDA‐MB‐435 originate from a common donor. This indicates that at some point in the past, one of these cell lines became misidentified, meaning that it ceased to correspond to the reported donor and instead became falsely identified (through cross‐contamination or other means) as a cell line from a different donor. Initial studies concluded that MDA‐MB‐435 was the misidentified cell line and M14 was the authentic cell line, although contradictory evidence has been published, resulting in further confusion. To address this question, we obtained early samples of the melanoma cell line (M14), a lymphoblastoid cell line from the same donor (ML14), and donor serum preserved at the originator's institution. M14 samples were cryopreserved in December 1975, before MDA‐MB‐435 cells were established in culture. Through a series of molecular characterizations, including short tandem repeat (STR) profiling and cytogenetic analysis, we demonstrated that later samples of M14 and MDA‐MB‐435 correspond to samples of M14 frozen in 1975, to the lymphoblastoid cell line ML14, and to the melanoma donor's STR profile, sex and blood type. This work demonstrates conclusively that M14 is the authentic cell line and MDA‐MB‐435 is misidentified. With clear provenance information and authentication testing of early samples, it is possible to resolve debates regarding the origins of problematic cell lines that are widely used in cancer research. PMID:28940260

  1. Determination of drugs in biological fluids by high-performance liquid chromatography with on-line sample processing.

    Science.gov (United States)

    Oertel, R; Richter, K; Gramatté, T; Kirch, W

    1998-02-27

    An automated two column HPLC system with the new packing material LiChrospher RP-18 ADS (alkyl-diol-silica) was tested for the determination of several drugs and metabolites (talinolol, celiprolol, metoprolol, oxprenolol, triamterene, trimethoprim, tiracizine, articaine, detajmium, ajmaline, lamotrigine) in various biological fluids (serum, urine, intestinal aspirates, supernatants of cell cultures and supernatants after protein denaturation). The method allows the direct injection of biological fluids into a reversed-phase HPLC system and on-line clean-up and sample enrichment by a column-switching technique. Precision, accuracy and sensitivity were similar to conventional assays as described in the literature. With this new method it was possible to measure drug concentrations in various biological fluids without changing the sample preparation procedure. In some cases an additional sample preparation like protein denaturation or solid-phase extraction was advantageous to enhance the sensitivity of the method and the life-time of the ADS column.

  2. Cable line engineering

    International Nuclear Information System (INIS)

    Jang, Hak Sin; Kim, Sin Yeong

    1998-02-01

    This book is about cable line engineering. It is comprised of nine chapters, which deals with summary of cable communication such as way, process of cable communication and optical communication, Line constant of transmission on primary constant, reflection and crosstalk, communication cable line of types like flat cable, coaxial cable and loaded cable, Install of communication line with types and facility of aerial line, construction method of communication line facility, Measurement of communication line, Carrier communication of summary, PCM communication with Introduction, regeneration relay system sampling and quantization and Electric communication service and general information network with mobile communication technique and satellite communication system.

  3. Assessment of aquifer system in the city of Lahore, Pakistan using isotopic techniques

    International Nuclear Information System (INIS)

    Ahmad, M.; Rafiq, M.; Akram, W.; Tasneem, M.A.; Ahmad, N.; Iqbal, N.; Sajjad, M.I.

    2002-01-01

    Isotopic and geochemical techniques were applied to assess the groundwater replenishment mechanism, pollution levels and pollution sources in the city of Lahore, the second largest city of Pakistan where water supply has been based on the abstraction of groundwater. Isotopic and chemical data indicates that groundwater has major contribution from the river water up to the center of the city while at remaining locations it seems base-flow recharged by rains of distant area or mixed recharge from river and rains. In case of shallow groundwater, different local sources like irrigation canals, sewerage drains, local rain and maybe the leaking main supply lines also contribute. High tritium values of deep groundwater fed by river show its quick movement up to 8-10 Km. Deep groundwater in the adjacent area towards the center of the city, although fed by the river shows residence time of about 45 years. Recharge to shallow aquifer is generally quick as most of the sampling locations have high tritium values. Chemical data shows that groundwater is mainly of sodium bicarbonate and calcium bicarbonate type. The infiltrating river water is of calcium bicarbonate type which changes to sodium bicarbonate type at few kilometers away from the river due to cation exchange and calcite precipitation processes. Water quality was assessed for drinking purpose and it was noted that concentrations of several parameters exceed the norms of good quality drinking water in case of shallow groundwater. This study clearly indicated an increasing trend of groundwater nitrate concentrations. δ 15 N values of high nitrate waters reveal the localized pollution from sewerage drains. Bacterial contamination of groundwater especially at locations near the drains also proves the penetration of urban recharge from sewerage drains. (author)

  4. Optical Variability of Narrow-line and Broad-line Seyfert 1 Galaxies

    Science.gov (United States)

    Rakshit, Suvendu; Stalin, C. S.

    2017-06-01

    We studied the optical variability (OV) of a large sample of narrow-line Seyfert 1 (NLSy1) and broad-line Seyfert 1 (BLSy1) galaxies with z anti-correlated with Fe II strength but correlated with the width of the Hβ line. The well-known anti-correlation of variability-luminosity and the variability-Eddington ratio is present in our data. Among the radio-loud sample, variability amplitude is found to be correlated with radio-loudness and radio-power, suggesting that jets also play an important role in the OV in radio-loud objects, in addition to the Eddington ratio, which is the main driving factor of OV in radio-quiet sources.

  5. Analysis of microcontaminants in aqueous samples by fully automated on-line solid-phase extraction-gas chromatography-mass selective detection.

    NARCIS (Netherlands)

    Louter, A.J.H.; van Beekvelt, C.A.; Cid Montanes, P.; Slobodník, J.; Vreuls, J.J.; Brinkman, U.A.T.

    1996-01-01

    The trace-level analysis of unknown organic pollutants in water requires the use of fast and sensitive methods which also provide structural information. In the present study, an on-line technique was used which combines sample preparation by means of solid-phase extraction (SPE) on a small

  6. Purity, adulteration and price of drugs bought on-line versus off-line in the Netherlands.

    Science.gov (United States)

    van der Gouwe, Daan; Brunt, Tibor M; van Laar, Margriet; van der Pol, Peggy

    2017-04-01

    On-line drug markets flourish and consumers have high expectations of on-line quality and drug value. The aim of this study was to (i) describe on-line drug purchases and (ii) compare on-line with off-line purchased drugs regarding purity, adulteration and price. Comparison of laboratory analyses of 32 663 drug consumer samples (stimulants and hallucinogens) purchased between January 2013 and January 2016, 928 of which were bought on-line. The Netherlands. Primary outcome measures were (i) the percentage of samples purchased on-line and (ii) the chemical purity of powders (or dosage per tablet); adulteration; and the price per gram, blotter or tablet of drugs bought on-line compared with drugs bought off-line. The proportion of drug samples purchased on-line increased from 1.4% in 2013 to 4.1% in 2015. The frequency varied widely, from a maximum of 6% for controlled, traditional substances [ecstasy tablets, 3,4-methylenedioxy-methamphetamine (MDMA) powder, amphetamine powder, cocaine powder, 4-bromo-2,5-dimethoxyphenethylamine (2C-B) and lysergic acid diethylamide (LSD)] to more than a third for new psychoactive substances (NPS) [4-fluoroamphetamine (4-FA), 5/6-(2-aminopropyl)benzofuran (5/6-APB) and methoxetamine (MXE)]. There were no large differences in drug purity, yet small but statistically significant differences were found for 4-FA (on-line 59% versus off-line 52% purity for 4-FA on average, P = 0.001), MDMA powders (45 versus 61% purity for MDMA, P = 0.02), 2C-B tablets (21 versus 10 mg 2C-B/tablet dosage, P = 0.49) and ecstasy tablets (131 versus 121 mg MDMA/tablet dosage, P = 0.05). The proportion of adulterated samples purchased on-line and off-line did not differ, except for 4-FA powder, being less adulterated on-line (χ 2  = 8.3; P < 0.02). Drug prices were mainly higher on-line, ranging for various drugs from 10 to 23% higher than that of drugs purchased off-line (six of 10 substances: P < 0.05). Dutch drug users increasingly

  7. Influence of the operating parameters and of the sample introduction system on time correlation of line intensities using an axially viewed CCD-based ICP-AES system

    Energy Technology Data Exchange (ETDEWEB)

    Grotti, Marco, E-mail: grotti@chimica.unige.i [Dipartimento di Chimica e Chimica Industriale, Via Dodecaneso 31, 16146 Genova (Italy); Todoli, Jose Luis [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, 03080, Alicante (Spain); Mermet, Jean Michel [Spectroscopy Forever, 01390 Tramoyes (France)

    2010-02-15

    The influence of the acquisition and operating parameters on time correlation between emission line intensities was investigated using axially viewed inductively coupled plasma-multichannel-based emission spectrometry and various sample introduction systems. It was found that to obtain flicker-noise limited signals, necessary to compensate for time-correlated signal fluctuations by internal standardization, the flicker-noise magnitude of the sample introduction system, the integration time and the emission line intensity had to be considered. The highest correlation between lines was observed for ultrasonic nebulization with desolvatation, the noisiest system among those considered, for which the contribution of the uncorrelated shot-noise was negligible. In contrast, for sample introduction systems characterized by lower flicker-noise levels, shot-noise led to high, non-correlated RSD values, making the internal standard method to be much less efficient. To minimize shot-noise, time correlation was improved by increasing the emission line intensities and the integration time. Improvement in repeatability did not depend only on time correlation, but also on the ratio between the relative standard deviations of the analytical and reference lines. The best signal compensation was obtained when RSD values of the reference and analytical lines were similar, which is usually obtained when the system is flicker-noise limited, while departure from similarity can lead to a degradation of repeatability when using the internal standard method. Moreover, the use of so-called robust plasma conditions, i.e. a high power (1500 W) along with a low carrier gas flow rate (0.8 L/min) improved also the compensation. Finally, high correlation and consequent improvement in repeatability by internal standardization was observed also in the presence of complex matrices (sediment and soil samples), although a matrix-induced degradation of the correlation between lines was generally

  8. [Analysis of phthalate esters in plastic-packaging bags on-line sample stacking-microemulsion electrokinetic chromatography].

    Science.gov (United States)

    Xiao, Jia; Huang, Ying; Wang, Minyi; Chen, Guonan

    2012-09-01

    Two convenient, effective, and reproducible methods using microemulsion electrokinetic chromatography (MEEKC)-normal stacking mode (NSM) and reversed electrode polarity stacking mode (REPSM) were developed for the on-line sample stacking of phthalate esters (PAEs). REPSM coupled with MEEKC increased the sensitivity of 937.5 to 7,143 times for four PAEs compared to the conventional MEEKC. The separating conditions in the MEEKC method were studied, and many factors influencing the two sample stacking processes were investigated in detail. The optimum sample matrices for the two stacking methods were as follows: 30 mmol/L sodium cholate (SC) and 30.0 mmol/L borate (pH 8.5). Additionally, sample injections as large as 3.45 kPa x 40 s and 3.45 kPa x 90 s were applied for NSM-MEEKC and REPSM-MEEKC, respectively. The linear relationship and reproducibility were also examined. Under the optimum conditions, the detection limits (S/N = 3) of the PAEs were in the ranges of 0.021 - 0.33 mg/L and 0.7 - 4 microg/L for NSM-MEEKC and REPSM-MEEKC, respectively. The proposed REPSM-MEEKC has been successfully applied to determine PAEs in plastic-packaging bags, and the spiked recoveries were in the range of 89.1% - 105.6% with satisfactory results.

  9. An integrated sample pretreatment platform for quantitative N-glycoproteome analysis with combination of on-line glycopeptide enrichment, deglycosylation and dimethyl labeling

    Energy Technology Data Exchange (ETDEWEB)

    Weng, Yejing; Qu, Yanyan; Jiang, Hao; Wu, Qi [National Chromatographic Research and Analysis Center, Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023 (China); University of the Chinese Academy of Sciences, Beijing 100039 (China); Zhang, Lihua, E-mail: lihuazhang@dicp.ac.cn [National Chromatographic Research and Analysis Center, Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023 (China); Yuan, Huiming [National Chromatographic Research and Analysis Center, Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023 (China); Zhou, Yuan [National Chromatographic Research and Analysis Center, Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023 (China); University of the Chinese Academy of Sciences, Beijing 100039 (China); Zhang, Xiaodan; Zhang, Yukui [National Chromatographic Research and Analysis Center, Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023 (China)

    2014-06-23

    Highlights: • An integrated platform for quantitative N-glycoproteome analysis was established. • On-line enrichment, deglycosylation and labeling could be achieved within 160 min. • A N{sub 2}-assisted interface was applied to improve the compatibility of the platform. • The platform exhibited improved quantification accuracy, precision and throughput. - Abstract: Relative quantification of N-glycoproteomes shows great promise for the discovery of candidate biomarkers and therapeutic targets. The traditional protocol for quantitative analysis of glycoproteomes is usually off-line performed, and suffers from long sample preparation time, and the risk of sample loss or contamination due to manual manipulation. In this study, a novel integrated sample preparation platform for quantitative N-glycoproteome analysis was established, with combination of online N-glycopeptide capture by a HILIC column, sample buffer exchange by a N{sub 2}-assisted HILIC–RPLC interface, deglycosylation by a hydrophilic PNGase F immobilized enzymatic reactor (hIMER) and solid dimethyl labeling on a C18 precolumn. To evaluate the performance of such a platform, two equal aliquots of immunoglobulin G (IgG) digests were sequentially pretreated, followed by MALDI-TOF MS analysis. The signal intensity ratio of heavy/light (H/L) labeled deglycosylated peptides with the equal aliquots was 1.00 (RSD = 6.2%, n = 3), much better than those obtained by the offline protocol, with H/L ratio as 0.76 (RSD = 11.6%, n = 3). Additionally, the total on-line sample preparation time was greatly shortened to 160 min, much faster than that of offline approach (24 h). Furthermore, such an integrated pretreatment platform was successfully applied to analyze the two kinds of hepatocarcinoma ascites syngeneic cell lines with high (Hca-F) and low (Hca-P) lymph node metastasis rates. For H/L labeled Hca-P lysates with the equal aliquots, 99.6% of log 2 ratios (H/L) of quantified glycopeptides ranged from −1

  10. Black hole mass estimates and emission-line properties of a sample of redshift z > 6.5 quasars

    Energy Technology Data Exchange (ETDEWEB)

    De Rosa, Gisella; Peterson, Bradley M.; Frank, Stephan [Department of Astronomy, The Ohio State University, 140 West 18th Avenue, Columbus, OH 43210 (United States); Venemans, Bram P.; Decarli, Roberto; Walter, Fabian [Max-Planck-Institut für Astronomie, Königstuhl 17, D-69117 Heidelberg (Germany); Gennaro, Mario [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD 21218 (United States); Simcoe, Robert A. [MIT-Kavli Center for Astrophysics and Space Research, 77 Massachusetts Avenue, Cambridge, MA 02139 (United States); Dietrich, Matthias [Department of Physics and Astronomy, Ohio University, Clippinger Lab 251B, Athens, OH 45701 (United States); McMahon, Richard G.; Hewett, Paul C. [Institute of Astronomy, University of Cambridge, Madingley Road, Cambridge CB3 0HA (United Kingdom); Mortlock, Daniel J. [Astrophysics Group, Imperial College London, Blackett Laboratory, Prince Consort Road, London, SW7 2AZ (United Kingdom); Simpson, Chris [Astrophysics Research Institute, Liverpool John Moores University, Liverpool Science Park, 146 Brownlow Hill, Liverpool L3 5RF (United Kingdom)

    2014-08-01

    We present the analysis of optical and near-infrared spectra of the only four z > 6.5 quasars known to date, discovered in the UKIDSS-LAS and VISTA-VIKING surveys. Our data set consists of new Very Large Telescope/X-Shooter and Magellan/FIRE observations. These are the best optical/NIR spectroscopic data that are likely to be obtained for the z > 6.5 sample using current 6-10 m facilities. We estimate the black hole (BH) mass, the Eddington ratio, and the Si IV/C IV, C III]/C IV, and Fe II/Mg II emission-line flux ratios. We perform spectral modeling using a procedure that allows us to derive a probability distribution for the continuum components and to obtain the quasar properties weighted upon the underlying distribution of continuum models. The z > 6.5 quasars show the same emission properties as their counterparts at lower redshifts. The z > 6.5 quasars host BHs with masses of ∼10{sup 9} M{sub ☉} that are accreting close to the Eddington luminosity ((log(L{sub Bol}/L{sub Edd})) = –0.4 ± 0.2), in agreement with what has been observed for a sample of 4.0 < z < 6.5 quasars. By comparing the Si IV/C IV and C III]/C IV flux ratios with the results obtained from luminosity-matched samples at z ∼ 6 and 2 ≤ z ≤ 4.5, we find no evidence of evolution of the line ratios with cosmic time. We compare the measured Fe II/Mg II flux ratios with those obtained for a sample of 4.0 < z < 6.4 sources. The two samples are analyzed using a consistent procedure. There is no evidence that the Fe II/Mg II flux ratio evolves between z = 7 and z = 4. Under the assumption that the Fe II/Mg II traces the Fe/Mg abundance ratio, this implies the presence of major episodes of chemical enrichment in the quasar hosts in the first ∼0.8 Gyr after the Big Bang.

  11. Radial line-scans as representative sampling strategy in dried-droplet laser ablation of liquid samples deposited on pre-cut filter paper disks

    Energy Technology Data Exchange (ETDEWEB)

    Nischkauer, Winfried [Institute of Chemical Technologies and Analytics, Vienna University of Technology, Vienna (Austria); Department of Analytical Chemistry, Ghent University, Ghent (Belgium); Vanhaecke, Frank [Department of Analytical Chemistry, Ghent University, Ghent (Belgium); Bernacchi, Sébastien; Herwig, Christoph [Institute of Chemical Engineering, Vienna University of Technology, Vienna (Austria); Limbeck, Andreas, E-mail: Andreas.Limbeck@tuwien.ac.at [Institute of Chemical Technologies and Analytics, Vienna University of Technology, Vienna (Austria)

    2014-11-01

    Nebulising liquid samples and using the aerosol thus obtained for further analysis is the standard method in many current analytical techniques, also with inductively coupled plasma (ICP)-based devices. With such a set-up, quantification via external calibration is usually straightforward for samples with aqueous or close-to-aqueous matrix composition. However, there is a variety of more complex samples. Such samples can be found in medical, biological, technological and industrial contexts and can range from body fluids, like blood or urine, to fuel additives or fermentation broths. Specialized nebulizer systems or careful digestion and dilution are required to tackle such demanding sample matrices. One alternative approach is to convert the liquid into a dried solid and to use laser ablation for sample introduction. Up to now, this approach required the application of internal standards or matrix-adjusted calibration due to matrix effects. In this contribution, we show a way to circumvent these matrix effects while using simple external calibration for quantification. The principle of representative sampling that we propose uses radial line-scans across the dried residue. This compensates for centro-symmetric inhomogeneities typically observed in dried spots. The effectiveness of the proposed sampling strategy is exemplified via the determination of phosphorus in biochemical fermentation media. However, the universal viability of the presented measurement protocol is postulated. Detection limits using laser ablation-ICP-optical emission spectrometry were in the order of 40 μg mL{sup −1} with a reproducibility of 10 % relative standard deviation (n = 4, concentration = 10 times the quantification limit). The reported sensitivity is fit-for-purpose in the biochemical context described here, but could be improved using ICP-mass spectrometry, if future analytical tasks would require it. Trueness of the proposed method was investigated by cross-validation with

  12. Radial line-scans as representative sampling strategy in dried-droplet laser ablation of liquid samples deposited on pre-cut filter paper disks.

    Science.gov (United States)

    Nischkauer, Winfried; Vanhaecke, Frank; Bernacchi, Sébastien; Herwig, Christoph; Limbeck, Andreas

    2014-11-01

    Nebulising liquid samples and using the aerosol thus obtained for further analysis is the standard method in many current analytical techniques, also with inductively coupled plasma (ICP)-based devices. With such a set-up, quantification via external calibration is usually straightforward for samples with aqueous or close-to-aqueous matrix composition. However, there is a variety of more complex samples. Such samples can be found in medical, biological, technological and industrial contexts and can range from body fluids, like blood or urine, to fuel additives or fermentation broths. Specialized nebulizer systems or careful digestion and dilution are required to tackle such demanding sample matrices. One alternative approach is to convert the liquid into a dried solid and to use laser ablation for sample introduction. Up to now, this approach required the application of internal standards or matrix-adjusted calibration due to matrix effects. In this contribution, we show a way to circumvent these matrix effects while using simple external calibration for quantification. The principle of representative sampling that we propose uses radial line-scans across the dried residue. This compensates for centro-symmetric inhomogeneities typically observed in dried spots. The effectiveness of the proposed sampling strategy is exemplified via the determination of phosphorus in biochemical fermentation media. However, the universal viability of the presented measurement protocol is postulated. Detection limits using laser ablation-ICP-optical emission spectrometry were in the order of 40 μg mL - 1 with a reproducibility of 10 % relative standard deviation (n = 4, concentration = 10 times the quantification limit). The reported sensitivity is fit-for-purpose in the biochemical context described here, but could be improved using ICP-mass spectrometry, if future analytical tasks would require it. Trueness of the proposed method was investigated by cross-validation with

  13. Radial line-scans as representative sampling strategy in dried-droplet laser ablation of liquid samples deposited on pre-cut filter paper disks

    Science.gov (United States)

    Nischkauer, Winfried; Vanhaecke, Frank; Bernacchi, Sébastien; Herwig, Christoph; Limbeck, Andreas

    2014-11-01

    Nebulising liquid samples and using the aerosol thus obtained for further analysis is the standard method in many current analytical techniques, also with inductively coupled plasma (ICP)-based devices. With such a set-up, quantification via external calibration is usually straightforward for samples with aqueous or close-to-aqueous matrix composition. However, there is a variety of more complex samples. Such samples can be found in medical, biological, technological and industrial contexts and can range from body fluids, like blood or urine, to fuel additives or fermentation broths. Specialized nebulizer systems or careful digestion and dilution are required to tackle such demanding sample matrices. One alternative approach is to convert the liquid into a dried solid and to use laser ablation for sample introduction. Up to now, this approach required the application of internal standards or matrix-adjusted calibration due to matrix effects. In this contribution, we show a way to circumvent these matrix effects while using simple external calibration for quantification. The principle of representative sampling that we propose uses radial line-scans across the dried residue. This compensates for centro-symmetric inhomogeneities typically observed in dried spots. The effectiveness of the proposed sampling strategy is exemplified via the determination of phosphorus in biochemical fermentation media. However, the universal viability of the presented measurement protocol is postulated. Detection limits using laser ablation-ICP-optical emission spectrometry were in the order of 40 μg mL- 1 with a reproducibility of 10 % relative standard deviation (n = 4, concentration = 10 times the quantification limit). The reported sensitivity is fit-for-purpose in the biochemical context described here, but could be improved using ICP-mass spectrometry, if future analytical tasks would require it. Trueness of the proposed method was investigated by cross-validation with

  14. BROAD ABSORPTION LINE DISAPPEARANCE ON MULTI-YEAR TIMESCALES IN A LARGE QUASAR SAMPLE

    Energy Technology Data Exchange (ETDEWEB)

    Filiz Ak, N.; Brandt, W. N.; Schneider, D. P. [Department of Astronomy and Astrophysics, Pennsylvania State University, University Park, PA 16802 (United States); Hall, P. B. [Department of Physics and Astronomy, York University, 4700 Keele St., Toronto, Ontario M3J 1P3 (Canada); Anderson, S. F.; Gibson, R. R. [Astronomy Department, University of Washington, Seattle, WA 98195 (United States); Lundgren, B. F. [Department of Physics, Yale University, New Haven, CT 06511 (United States); Myers, A. D. [Department of Physics and Astronomy, University of Wyoming, Laramie, WY 82071 (United States); Petitjean, P. [Institut d' Astrophysique de Paris, Universite Paris 6, F-75014, Paris (France); Ross, Nicholas P. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 92420 (United States); Shen Yue [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, MS-51, Cambridge, MA 02138 (United States); York, D. G. [Department of Astronomy and Astrophysics, and Enrico Fermi Institute, University of Chicago, 5640 S. Ellis Ave., Chicago, IL 60637 (United States); Bizyaev, D.; Brinkmann, J.; Malanushenko, E.; Oravetz, D. J.; Pan, K.; Simmons, A. E. [Apache Point Observatory, P.O. Box 59, Sunspot, NM 88349-0059 (United States); Weaver, B. A., E-mail: nfilizak@astro.psu.edu [Center for Cosmology and Particle Physics, New York University, New York, NY 10003 (United States)

    2012-10-01

    We present 21 examples of C IV broad absorption line (BAL) trough disappearance in 19 quasars selected from systematic multi-epoch observations of 582 bright BAL quasars (1.9 < z < 4.5) by the Sloan Digital Sky Survey-I/II (SDSS-I/II) and SDSS-III. The observations span 1.1-3.9 yr rest-frame timescales, longer than have been sampled in many previous BAL variability studies. On these timescales, Almost-Equal-To 2.3% of C IV BAL troughs disappear and Almost-Equal-To 3.3% of BAL quasars show a disappearing trough. These observed frequencies suggest that many C IV BAL absorbers spend on average at most a century along our line of sight to their quasar. Ten of the 19 BAL quasars showing C IV BAL disappearance have apparently transformed from BAL to non-BAL quasars; these are the first reported examples of such transformations. The BAL troughs that disappear tend to be those with small-to-moderate equivalent widths, relatively shallow depths, and high outflow velocities. Other non-disappearing C IV BALs in those nine objects having multiple troughs tend to weaken when one of them disappears, indicating a connection between the disappearing and non-disappearing troughs, even for velocity separations as large as 10,000-15,000 km s{sup -1}. We discuss possible origins of this connection including disk-wind rotation and changes in shielding gas.

  15. Optical Variability of Narrow-line and Broad-line Seyfert 1 Galaxies

    Energy Technology Data Exchange (ETDEWEB)

    Rakshit, Suvendu; Stalin, C. S., E-mail: suvenduat@gmail.com [Indian Institute of Astrophysics, Block II, Koramangala, Bangalore-560034 (India)

    2017-06-20

    We studied the optical variability (OV) of a large sample of narrow-line Seyfert 1 (NLSy1) and broad-line Seyfert 1 (BLSy1) galaxies with z < 0.8 to investigate any differences in their OV properties. Using archival optical V -band light curves from the Catalina Real Time Transient Survey that span 5–9 years and modeling them using damped random walk, we estimated the amplitude of variability. We found that NLSy1 galaxies as a class show lower amplitude of variability than their broad-line counterparts. In the sample of both NLSy1 and BLSy1 galaxies, radio-loud sources are found to have higher variability amplitude than radio-quiet sources. Considering only sources that are detected in the X-ray band, NLSy1 galaxies are less optically variable than BLSy1 galaxies. The amplitude of variability in the sample of both NLSy1 and BLSy1 galaxies is found to be anti-correlated with Fe ii strength but correlated with the width of the H β line. The well-known anti-correlation of variability–luminosity and the variability–Eddington ratio is present in our data. Among the radio-loud sample, variability amplitude is found to be correlated with radio-loudness and radio-power, suggesting that jets also play an important role in the OV in radio-loud objects, in addition to the Eddington ratio, which is the main driving factor of OV in radio-quiet sources.

  16. Water works Slatinka, Garajky, Hroncek and Tichy potok for public profit

    International Nuclear Information System (INIS)

    Holcik, V.

    2003-01-01

    There is 2890 towns and villages in Slovak Republic. About 2030 has drinking water from public ducting. Worse situation is in waste water off take - only about 490 villages are connected to public sewerage. It is necessary to have drinking water at disposal (from underground and ground sources), consequently ducting with water finishing department and at the end sewerage with water purifier. But Slovak Republic is country that has never had enough money for such investments as building drinking water basin, to process and distribute water to 38 villages and to build sewerage and water purifier for these villages. If we want to be equal partner to another European Union countries thus all villages above 2000 inhabitants should have ducting and sewerage. In Slovak Republic there is about 295 villages without ducting and sewerage. First, the source is necessary, then duct and then sewerage, not conversely. Structural, cohesive and other European Union funds should be used also for building of drinking water basins and connecting ducts and sewerage. I am confident that water works Slatinka, Garajky, Hroncek and Tichy Potok recommended by Ministry of Land management are necessary to be built and it will be for public profit

  17. Fate of Zinc and Silver Engineered Nanoparticles in ...

    Science.gov (United States)

    Engineered zinc oxide (ZnO) and silver (Ag) nanoparticles (NPs) used in consumer products are largely released into the environment through the wastewater stream. Limited information is available regarding the transformations they undergo during their transit through sewerage systems before reaching wastewater treatment plants. To address this knowledge gap, laboratory-scale systems fed with raw wastewater were used to evaluate the transformation of ZnO- and Ag-NPs within sewerage transfer networks. Two experimental systems were established and spiked with either Ag- and ZnO-NPs or with their dissolved salts, and the wastewater influent and effluent samples from both systems were thoroughly characterised. X-ray absorption spectroscopy (XAS) was used to assess the extent of the chemical transformation of both forms of Zn and Ag during transport through the model systems. The results indicated that both ZnO- and Ag-NPs underwent significant transformation during their transport through the sewerage network. Reduced sulphur species represented the most important endpoint for these NPs in the sewer with slight differences in terms of speciation; ZnO converted largely to Zn sulfide, while Ag was also sorbed to cysteine and histidine. Importantly, both ionic Ag and Ag-NPs formed secondary Ag sulfide nanoparticles in the sewerage network as revealed by TEM analysis. Ag-cysteine was also shown to be a major species in biofilms. These results were verified in the

  18. Options for alternative types of sewerage and treatment systems directed to improvement of the overall performance.

    Science.gov (United States)

    Otterpohl, R

    2002-01-01

    Technology for future houses may well include a high-tech water recycling unit that makes tapwater while people drink bottled water of high quality. There may be toilets that produce just a bag of dry fertiliser per year, hopefully without fossil energy. Rainwater infiltration is increasingly replacing storm sewers anyway. Many urban areas of the future could simply be without sewerage systems. Technical feasibility is given even today and economic feasability is coming closer by advances in membrane technology. However, there are more likely scenarios than this. One person produces about 500 litres of urine and 50 litres of faeces per year (= blackwater). The same person, produces in a range of 20,000 to over 100,000 litres of wastewater. Black- and greywater (wastewater without toilet) do have very different characteristics. If blackwater is collected separately with low dilution it can be converted to safe natural fertiliser, replacing synthetic products and preventing spreadout of pathogens and other pollutants to receiving waters. New sanitation concepts are now built in several countries as pilot projects. One example is a vacuum-biogas system for around 400 inhabitants that has been built in Lübeck, Germany. It does perform recovery of resources and energy in an urban area. This type of sanitation can serve around up to 10,000 people and can be arranged in independent modules for larger settlements. Another pilot project based on urine-sorting flush toilets (no-mix-toilets) has been built in the rural water-mill museum "Lambertsmühle" near Cologne, Germany. Urine or yellow water is collected with low dilution and can be used as fertiliser as projects in Sweden have shown--the nutrient composition suits many types of soil. Brownwater (the solids and flush from the sorting toilet) is converted to small volume by a two-chamber composting tank with a filtration system. The compost can be used as soil conditioner. These and other concepts can be economic and

  19. Solid-phase extraction of polar pesticides from environmental water samples on graphitized carbon and Empore-activated carbon disks and on-line coupling to octadecyl-bonded silica analytical columns.

    NARCIS (Netherlands)

    Slobodník, J.; Oztekizan, O.; Lingeman, H.; Brinkman, U.A.T.

    1996-01-01

    The suitability of Empore-activated carbon disks (EACD), Envi-Carb graphitized carbon black (GCB) and CPP-50 graphitized carbon for the trace enrichment of polar pesticides from water samples was studied by means of off-line and on-line solid-phase extraction (SPE). In the off-line procedure, 0.5-2

  20. Development of on-line electrochemical sample pretreatment methods for the analysis of thallium and uranium by ICP-MS

    International Nuclear Information System (INIS)

    Zhou, F.; Van Berkel, G.J.; Morton, S.J.; Duckworth, D.C.; Adeniyi, W.K.; Keller, J.M.

    1995-01-01

    Anodic and adsorptive stripping voltammetry (AWV and AdSV, respectively) were performed on-line with a mercury thin-film electrode (MTFE) to effect the selective accumulation and detection of thallium and uranium, respectively. ASV-ICP-MS experiments using thallium as the test element were performed to characterize the behavior of the on-line system for low level and quantitative determinations. Excellent linearity in response was demonstrated for thallium standards ranging from 0.25 ng/L to 50 microg/L. The 1.0 pg/L detection limit calculated from this data for thallium (3σ/sensitivity) was 400 times lower than that of conventional ICP-MS. The ability to overcome sample matrix effects in quantitative determinations was demonstrated by the analysis of an undiluted synthetic urine sample. AdSV-ICP-MS experiments were performed using uranium as the test element to demonstrate the utility of this method for the determination of radiologically important elements. A uranium(VI)-cupferron complex was used to effect adsorptive accumulation of uranium from a 10 microg/L standard solution onto the MTFE. The uranium was chemically stripped from the electrode for subsequent downstream detection by the ICP-MS. The quantitative nature of this method and a modest enhancement of signal levels (∼X10) over those levels obtained with conventional ICP-MS for samples in the microgram/liter concentration range were demonstrated. Modifications to the current system to provide low flow rate operation will allow further optimization of the ASV-ICP-MS and AdSV-ICP-MS combinations

  1. Boosting Lyα and He II λ1640 Line Fluxes from Population III Galaxies: Stochastic IMF Sampling and Departures from Case-B

    Science.gov (United States)

    Mas-Ribas, Lluís; Dijkstra, Mark; Forero-Romero, Jaime E.

    2016-12-01

    We revisit calculations of nebular hydrogen Lyα and He II λ1640 line strengths for Population III (Pop III) galaxies, undergoing continuous, and bursts of, star formation. We focus on initial mass functions (IMFs) motivated by recent theoretical studies, which generally span a lower range of stellar masses than earlier works. We also account for case-B departures and the stochastic sampling of the IMF. In agreement with previous work, we find that departures from case-B can enhance the Lyα flux by a factor of a few, but we argue that this enhancement is driven mainly by collisional excitation and ionization, and not due to photoionization from the n = 2 state of atomic hydrogen. The increased sensitivity of the Lyα flux to the high-energy end of the galaxy spectrum makes it more subject to stochastic sampling of the IMF. The latter introduces a dispersion in the predicted nebular line fluxes around the deterministic value by as much as a factor of ˜4. In contrast, the stochastic sampling of the IMF has less impact on the emerging Lyman Werner photon flux. When case-B departures and stochasticity effects are combined, nebular line emission from Pop III galaxies can be up to one order of magnitude brighter than predicted by “standard” calculations that do not include these effects. This enhances the prospects for detection with future facilities such as the James Webb Space Telescope and large, ground-based telescopes.

  2. On-line sample processing methods in flow analysis

    DEFF Research Database (Denmark)

    Miró, Manuel; Hansen, Elo Harald

    2008-01-01

    In this chapter, the state of the art of flow injection and related approaches thereof for automation and miniaturization of sample processing regardless of the aggregate state of the sample medium is overviewed. The potential of the various generation of flow injection for implementation of in...

  3. BROAD ABSORPTION LINE VARIABILITY ON MULTI-YEAR TIMESCALES IN A LARGE QUASAR SAMPLE

    Energy Technology Data Exchange (ETDEWEB)

    Filiz Ak, N.; Brandt, W. N.; Schneider, D. P. [Department of Astronomy and Astrophysics, Pennsylvania State University, University Park, PA 16802 (United States); Hall, P. B. [Department of Physics and Astronomy, York University, 4700 Keele St., Toronto, Ontario, M3J 1P3 (Canada); Anderson, S. F. [Astronomy Department, University of Washington, Seattle, WA 98195 (United States); Hamann, F. [Department of Astronomy, University of Florida, Gainesville, FL 32611-2055 (United States); Lundgren, B. F. [Department of Astronomy, University of Wisconsin, Madison, WI 53706 (United States); Myers, Adam D. [Department of Physics and Astronomy, University of Wyoming, Laramie, WY 82071 (United States); Pâris, I. [Departamento de Astronomía, Universidad de Chile, Casilla 36-D, Santiago (Chile); Petitjean, P. [Universite Paris 6, Institut d' Astrophysique de Paris, 75014, Paris (France); Ross, Nicholas P. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 92420 (United States); Shen, Yue [Harvard-Smithsonian Center for Astrophysics, 60 Garden St., MS-51, Cambridge, MA 02138 (United States); York, Don, E-mail: nfilizak@astro.psu.edu [The University of Chicago, Department of Astronomy and Astrophysics, Chicago, IL 60637 (United States)

    2013-11-10

    We present a detailed investigation of the variability of 428 C IV and 235 Si IV broad absorption line (BAL) troughs identified in multi-epoch observations of 291 quasars by the Sloan Digital Sky Survey-I/II/III. These observations primarily sample rest-frame timescales of 1-3.7 yr over which significant rearrangement of the BAL wind is expected. We derive a number of observational results on, e.g., the frequency of BAL variability, the velocity range over which BAL variability occurs, the primary observed form of BAL-trough variability, the dependence of BAL variability upon timescale, the frequency of BAL strengthening versus weakening, correlations between BAL variability and BAL-trough profiles, relations between C IV and Si IV BAL variability, coordinated multi-trough variability, and BAL variations as a function of quasar properties. We assess implications of these observational results for quasar winds. Our results support models where most BAL absorption is formed within an order-of-magnitude of the wind-launching radius, although a significant minority of BAL troughs may arise on larger scales. We estimate an average lifetime for a BAL trough along our line-of-sight of a few thousand years. BAL disappearance and emergence events appear to be extremes of general BAL variability, rather than being qualitatively distinct phenomena. We derive the parameters of a random-walk model for BAL EW variability, finding that this model can acceptably describe some key aspects of EW variability. The coordinated trough variability of BAL quasars with multiple troughs suggests that changes in 'shielding gas' may play a significant role in driving general BAL variability.

  4. BOOSTING LY α   AND He ii λ 1640 LINE FLUXES FROM POPULATION III GALAXIES: STOCHASTIC IMF SAMPLING AND DEPARTURES FROM CASE-B

    International Nuclear Information System (INIS)

    Mas-Ribas, Lluís; Dijkstra, Mark; Forero-Romero, Jaime E.

    2016-01-01

    We revisit calculations of nebular hydrogen Ly α and He ii λ 1640 line strengths for Population III (Pop III) galaxies, undergoing continuous, and bursts of, star formation. We focus on initial mass functions (IMFs) motivated by recent theoretical studies, which generally span a lower range of stellar masses than earlier works. We also account for case-B departures and the stochastic sampling of the IMF. In agreement with previous work, we find that departures from case-B can enhance the Ly α flux by a factor of a few, but we argue that this enhancement is driven mainly by collisional excitation and ionization, and not due to photoionization from the n  = 2 state of atomic hydrogen. The increased sensitivity of the Ly α flux to the high-energy end of the galaxy spectrum makes it more subject to stochastic sampling of the IMF. The latter introduces a dispersion in the predicted nebular line fluxes around the deterministic value by as much as a factor of ∼4. In contrast, the stochastic sampling of the IMF has less impact on the emerging Lyman Werner photon flux. When case-B departures and stochasticity effects are combined, nebular line emission from Pop III galaxies can be up to one order of magnitude brighter than predicted by “standard” calculations that do not include these effects. This enhances the prospects for detection with future facilities such as the James Webb Space Telescope and large, ground-based telescopes.

  5. Automation and integration of multiplexed on-line sample preparation with capillary electrophoresis for DNA sequencing

    Energy Technology Data Exchange (ETDEWEB)

    Tan, H.

    1999-03-31

    The purpose of this research is to develop a multiplexed sample processing system in conjunction with multiplexed capillary electrophoresis for high-throughput DNA sequencing. The concept from DNA template to called bases was first demonstrated with a manually operated single capillary system. Later, an automated microfluidic system with 8 channels based on the same principle was successfully constructed. The instrument automatically processes 8 templates through reaction, purification, denaturation, pre-concentration, injection, separation and detection in a parallel fashion. A multiplexed freeze/thaw switching principle and a distribution network were implemented to manage flow direction and sample transportation. Dye-labeled terminator cycle-sequencing reactions are performed in an 8-capillary array in a hot air thermal cycler. Subsequently, the sequencing ladders are directly loaded into a corresponding size-exclusion chromatographic column operated at {approximately} 60 C for purification. On-line denaturation and stacking injection for capillary electrophoresis is simultaneously accomplished at a cross assembly set at {approximately} 70 C. Not only the separation capillary array but also the reaction capillary array and purification columns can be regenerated after every run. DNA sequencing data from this system allow base calling up to 460 bases with accuracy of 98%.

  6. Determination of total and inorganic mercury in fish samples with on-line oxidation coupled to atomic fluorescence spectrometry

    International Nuclear Information System (INIS)

    Shao Lijun; Gan Wuer; Su Qingde

    2006-01-01

    An atomic fluorescence spectrometry system for determination of total and inorganic mercury with electromagnetic induction-assisted heating on-line oxidation has been developed. Potassium peroxodisulphate was used as the oxidizing agent to decompose organomercury compounds. Depending on the temperature selected, inorganic or total mercury could be determined with the same manifold. Special accent was put on the study of the parameters influencing the on-line digestion efficiency. The tolerance to the interference of coexisting ions was carefully examined in this system. Under optimal conditions, the detection limits (3σ) were evaluated to be 2.9 ng l -1 for inorganic mercury and 2.6 ng l -1 for total mercury, respectively. The relative standard deviations for 10 replicate determinations of 1.0 μg l -1 Hg were 2.4 and 3.2% for inorganic mercury and total mercury, respectively. The proposed method was successfully applied to the determination of total and inorganic mercury in fish samples

  7. Investigation of Wastewater Pollution at Clan Jetty, Penang

    Directory of Open Access Journals (Sweden)

    Razak Fazilah Md

    2014-01-01

    Full Text Available This study aims to determine the level of wastewater pollution at Clan Jetty, Penang. 20 locations were chosen for water sampling around the jetties. Experiments were conducted to investigate the parameters, namely, temperature at each point, Chemical Oxygen Demand (COD, Biochemical Oxygen Demand (BOD, pH, Dissolved Oxygen (DO, the presence of Coliform and E. coli, Nitrate Nitrogen, Ammonical Nitrogen, Suspended Solids, Oil and Grease as well as Total Phosphorus (TP. Laboratory results showed that Point 1A was the most polluted location compared to other sampling points. The highest COD recording was 5824 mg/L at Point 1A and the lowest amount of 103 mg/L was recorded at Point 4. This study demonstrates that the absence of a sewerage system contributes to marine pollution around the jetties. Thus, a sewerage system is the best solution to improve water quality around the jetties in the future.

  8. Solid-phase extraction of polar pesticides from environmental water samples on graphitized carbon and Empore-activated carbon disks and on-line coupling to octadecyl-bonded silica analytical columns.

    Science.gov (United States)

    Slobodník, J; Oztezkizan, O; Lingeman, H; Brinkman, U A

    1996-10-25

    The suitability of Empore-activated carbon disks (EACD), Envi-Carb graphitized carbon black (GCB) and CPP-50 graphitized carbon for the trace enrichment of polar pesticides from water samples was studied by means of off-line and on-line solid-phase extraction (SPE). In the off-line procedure, 0.5-2 l samples spiked with a test mixture of oxamyl, methomyl and aldicarb sulfoxide were enriched on EnviCarb SPE cartridges or 47 mm diameter EACD and eluted with dichloromethane-methanol. After evaporation, a sample was injected onto a C18-bonded silica column and analysed by liquid chromatography with ultraviolet (LC-UV) detection. EACD performed better than EnviCarb cartridges in terms of breakthrough volumes (> 2 l for all test analytes), reproducibility (R.S.D. of recoveries, 4-8%, n = 3) and sampling speed (100 ml/min); detection limits in drinking water were 0.05-0.16 microgram/l. In the on-line experiments, 4.6 mm diameter pieces cut from original EACD and stacked onto each other in a 9 mm long precolumn, and EnviCarb and CPP-50 packed in 10 x 2.0 mm I.D. precolumn, were tested, and 50-200 ml spiked water samples were preconcentrated. Because of the peak broadening caused by the strong sorption of the analytes on carbon, the carbon-packed precolumns were eluted by a separate stream of 0.1 ml/min acetonitrile which was mixed with the gradient LC eluent in front of the C18 analytical column. The final on-line procedure was also applied for the less polar propoxur, carbaryl and methiocarb. EnviCarb could not be used due to its poor pressure resistance. CPP-50 provided less peak broadening than EACD: peak widths were 0.1-0.3 min and R.S.D. of peak heights 4-14% (n = 3). In terms of analyte trapping efficiency on-line SPE-LC-UV with a CPP-50 precolumn also showed better performance than when Bondesil C18/OH or polymeric PLRP-S was used, but chromatographic resolution was similar. With the CPP-50-based system, detection limits of the test compounds were 0.05-1 microgram

  9. PERENCANAAN SISTEM PENYALURAN AIR LIMBAH DOMESTIK KOTA BOGOR MENGGUNAKAN AIR HUJAN UNTUK DEBIT PENGGELONTORAN (Planning of Domestic Wastewater Sewerage in Bogor City Using Rainwater for Flushing Flowrate

    Directory of Open Access Journals (Sweden)

    Allen Kurniawan

    2015-03-01

    Full Text Available ABSTRAK Sistem penyaluran air limbah merupakan bagian penting dalam sistem prasarana perkotaan. Tujuan penelitian ini merancang konfigurasi sistem penyaluran air limbah domestik dan memodifikasi sistem drainase skala mikro di Kota Bogor untuk memenuhi debit penggelontoran. Data penelitian berupa data sekunder dari instansi terkait, studi pustaka, dan hasil beberapa penelitian terdahulu. Perkiraan jumlah penduduk setiap kelurahan pada tahun perencanaan 2035 menggunakan metode geometrik. Instalasi Pengolahan Air Limbah (IPAL dibangun pada dua lokasi yaitu IPAL 1 di Kelurahan Bantarjati dan IPAL 2 di Kelurahan Mekarwangi. Perencanaan blok pelayanan sebanyak 254 buah dan jumlah manhole sebanyak 334 buah. Perhitungan kebutuhan air bersih menghasilkan nilai debit jam puncak air limbah (Qjp rata-rata sebesar 5,75 L/detik. Debit air bersih menghasilkan perkiraan sebesar 80% air limbah. Nilai Qp pada inlet IPAL 1 sebesar 0,59 m3/detik dengan diameter 900 mm, sedangkan nilai Qp pada inlet IPAL 2 sebesar 1,42 m3/detik dengan diameter 1000 mm. Pengaliran air limbah diusahakan secara gravitasi dengan kedalaman galian maksimum sebesar 6 m. Sistem drainase skala mikro dirancang untuk memenuhi debit penggelontoran. Perhitungan intensitas hujan terpilih menggunakan Metode Sherman. Titik penggelontoran sebanyak 53 titik dengan debit penggelontoran rata-rata sebesar 0,03 m3/detik. Debit saluran drainase rata-rata sebesar 0,25 m3/detik. ABSTRACT Sewerage system is an important part of the urban infrastructure. The research objectives were to design a system configuration domestic wastewater sewerage and modify drainage systems in Bogor City for flushing discharge. The research used secondary data from relevant institutions, literature, and the results of previous researches. Estimated of the population of each village in 2035 used geometric method. Wastewater Treatment Plant (WWTP would be constructed in two locations in Bantarjati and Mekarwangi Village. Planning

  10. Derivative spectrum chromatographic method for the determination of trimethoprim in honey samples using an on-line solid-phase extraction technique.

    Science.gov (United States)

    Uchiyama, Kazuhisa; Kondo, Mari; Yokochi, Rika; Takeuchi, Yuri; Yamamoto, Atsushi; Inoue, Yoshinori

    2011-07-01

    A simple, selective and rapid analytical method for determination of trimethoprim (TMP) in honey samples was developed and validated. This method is based on a SPE technique followed by HPLC with photodiode array detection. After dilution and filtration, aliquots of 500 μL honey samples were directly injected to an on-line SPE HPLC system. TMP was extracted on an RP SPE column, and separated on a hydrophilic interaction chromatography column during HPLC analysis. At the first detection step, the noise level of the photodiode array data was reduced with two-dimensional equalizer filtering, and then the smoothed data were subjected to derivative spectrum chromatography. On the second-derivative chromatogram at 254 nm, the limit of detection and the limit of quantification of TMP in a honey sample were 5 and 10 ng/g, respectively. The proposed method showed high accuracy (60-103%) with adequate sensitivity for TMP monitoring in honey samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. MICROLENSING OF QUASAR BROAD EMISSION LINES: CONSTRAINTS ON BROAD LINE REGION SIZE

    Energy Technology Data Exchange (ETDEWEB)

    Guerras, E.; Mediavilla, E. [Instituto de Astrofisica de Canarias, Via Lactea S/N, La Laguna E-38200, Tenerife (Spain); Jimenez-Vicente, J. [Departamento de Fisica Teorica y del Cosmos, Universidad de Granada, Campus de Fuentenueva, E-18071 Granada (Spain); Kochanek, C. S. [Department of Astronomy and the Center for Cosmology and Astroparticle Physics, The Ohio State University, 4055 McPherson Lab, 140 West 18th Avenue, Columbus, OH 43221 (United States); Munoz, J. A. [Departamento de Astronomia y Astrofisica, Universidad de Valencia, E-46100 Burjassot, Valencia (Spain); Falco, E. [Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Motta, V. [Departamento de Fisica y Astronomia, Universidad de Valparaiso, Avda. Gran Bretana 1111, Valparaiso (Chile)

    2013-02-20

    We measure the differential microlensing of the broad emission lines between 18 quasar image pairs in 16 gravitational lenses. We find that the broad emission lines are in general weakly microlensed. The results show, at a modest level of confidence (1.8{sigma}), that high ionization lines such as C IV are more strongly microlensed than low ionization lines such as H{beta}, indicating that the high ionization line emission regions are more compact. If we statistically model the distribution of microlensing magnifications, we obtain estimates for the broad line region size of r{sub s} = 24{sup +22} {sub -15} and r{sub s} = 55{sup +150} {sub -35} lt-day (90% confidence) for the high and low ionization lines, respectively. When the samples are divided into higher and lower luminosity quasars, we find that the line emission regions of more luminous quasars are larger, with a slope consistent with the expected scaling from photoionization models. Our estimates also agree well with the results from local reveberation mapping studies.

  12. Applying a Modified Triad Approach to Investigate Wastewater lines

    International Nuclear Information System (INIS)

    Pawlowicz, R.; Urizar, L.; Blanchard, S.; Jacobsen, K.; Scholfield, J.

    2006-01-01

    Approximately 20 miles of wastewater lines are below grade at an active military Base. This piping network feeds or fed domestic or industrial wastewater treatment plants on the Base. Past wastewater line investigations indicated potential contaminant releases to soil and groundwater. Further environmental assessment was recommended to characterize the lines because of possible releases. A Remedial Investigation (RI) using random sampling or use of sampling points spaced at predetermined distances along the entire length of the wastewater lines, however, would be inefficient and cost prohibitive. To accomplish RI goals efficiently and within budget, a modified Triad approach was used to design a defensible sampling and analysis plan and perform the investigation. The RI task was successfully executed and resulted in a reduced fieldwork schedule, and sampling and analytical costs. Results indicated that no major releases occurred at the biased sampling points. It was reasonably extrapolated that since releases did not occur at the most likely locations, then the entire length of a particular wastewater line segment was unlikely to have contaminated soil or groundwater and was recommended for no further action. A determination of no further action was recommended for the majority of the waste lines after completing the investigation. The modified Triad approach was successful and a similar approach could be applied to investigate wastewater lines on other United States Department of Defense or Department of Energy facilities. (authors)

  13. On-line Automated Sample Preparation-Capillary Gas Chromatography for the Analysis of Plasma Samples.

    NARCIS (Netherlands)

    Louter, A.J.H.; van der Wagt, R.A.C.A.; Brinkman, U.A.T.

    1995-01-01

    An automated sample preparation module, (the automated sample preparation with extraction columns, ASPEC), was interfaced with a capillary gas chromatograph (GC) by means of an on-column interface. The system was optimised for the determination of the antidepressant trazodone in plasma. The clean-up

  14. PIXE analysis of U and Pu from hot particles: K-lines vs L-lines

    DEFF Research Database (Denmark)

    Jiménez-Ramos, M.C.; García López, J.; Eriksson, M.

    2012-01-01

    . (2007) [1] and Jiménez-Ramos et al. (2010) [2], radioactive particles from aircraft accidents in Palomares and Thule have been characterized. Using micro-Proton Induced X-ray Emission (μ-PIXE) and confocal X-ray fluorescence microprobe (μ-XRF), the L-lines of the main components in these particles, U......-lines present not overlapping between the main peaks in the spectra and the X-ray absorption in the sample is much lower than for L-lines....

  15. Validation of a high performance liquid chromatography analysis for the determination of noradrenaline and adrenaline in human urine with an on-line sample purification

    DEFF Research Database (Denmark)

    Hansen, Åse Marie; Kristiansen, J; Nielsen, J L

    1999-01-01

    A high performance liquid chromatography (HPLC) method with fluorescence detection including an on-line purification was established for determination of catecholamines in human urine. The method was evaluated using samples of pooled urine spiked with catecholamines and validated for measurements...

  16. MID-INFRARED ATOMIC FINE-STRUCTURE EMISSION-LINE SPECTRA OF LUMINOUS INFRARED GALAXIES: SPITZER/IRS SPECTRA OF THE GOALS SAMPLE

    Energy Technology Data Exchange (ETDEWEB)

    Inami, H. [National Optical Astronomy Observatory, Tucson, AZ 85719 (United States); Armus, L.; Stierwalt, S.; Díaz-Santos, T.; Surace, J.; Howell, J.; Marshall, J. [Spitzer Science Center, California Institute of Technology, CA 91125 (United States); Charmandaris, V. [Department of Physics and Institute of Theoretical and Computational Physics, University of Crete, GR-71003 Heraklion (Greece); Groves, B. [Max Planck Institute for Astronomy, Königstuhl 17, D-69117 Heidelberg (Germany); Kewley, L. [Research School of Astronomy and Astrophysics, The Australian National University, Cotter Road, Weston Creek, ACT 2611 (Australia); Petric, A. [Department of Astronomy, California Institute of Technology, MS 320-47, Pasadena, CA 91125 (United States); Rich, J. [The Observatories, Carnegie Institute of Washington, 813 Santa Barbara Street, Pasadena, CA 91101 (United States); Haan, S. [CSIRO Astronomy and Space Science, Marsfield, NSW 2122 (Australia); Evans, A. S. [Department of Astronomy, University of Virginia, P.O. Box 400325, Charlottesville, VA 22904 (United States); Mazzarella, J.; Lord, S. [Infrared Processing and Analysis Center, MS 100-22, California Institute of Technology, Pasadena, CA 91125 (United States); Appleton, P. [NASA Herschel Science Center, 770 South Wilson Avenue, Pasadena, CA 91125 (United States); Spoon, H. [Astronomy Department, Cornell University, Ithaca, NY 14853 (United States); Frayer, D. [National Radio Astronomy Observatory, P.O. Box 2, Green Bank, WV 24944 (United States); Matsuhara, H., E-mail: inami@noao.edu [Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency (Japan); and others

    2013-11-10

    We present the data and our analysis of mid-infrared atomic fine-structure emission lines detected in Spitzer/Infrared Spectrograph high-resolution spectra of 202 local Luminous Infrared Galaxies (LIRGs) observed as part of the Great Observatories All-sky LIRG Survey (GOALS). We readily detect emission lines of [S IV], [Ne II], [Ne V], [Ne III], [S III]{sub 18.7{sub μm}}, [O IV], [Fe II], [S III]{sub 33.5{sub μm}}, and [Si II]. More than 75% of these galaxies are classified as starburst-dominated sources in the mid-infrared, based on the [Ne V]/[Ne II] line flux ratios and equivalent width of the 6.2 μm polycyclic aromatic hydrocarbon feature. We compare ratios of the emission-line fluxes to those predicted from stellar photo-ionization and shock-ionization models to constrain the physical and chemical properties of the gas in the starburst LIRG nuclei. Comparing the [S IV]/[Ne II] and [Ne III]/[Ne II] line ratios to the Starburst99-Mappings III models with an instantaneous burst history, the emission-line ratios suggest that the nuclear starbursts in our LIRGs have ages of 1-4.5 Myr, metallicities of 1-2 Z{sub ☉}, and ionization parameters of 2-8 × 10{sup 7} cm s{sup –1}. Based on the [S III]{sub 33.5{sub μm}}/[S III]{sub 18.7{sub μm}} ratios, the electron density in LIRG nuclei is typically one to a few hundred cm{sup –3}, with a median electron density of ∼300 cm{sup –3}, for those sources above the low density limit for these lines. We also find that strong shocks are likely present in 10 starburst-dominated sources of our sample. A significant fraction of the GOALS sources (80) have resolved neon emission-line profiles (FWHM ≥600 km s{sup –1}) and five show clear differences in the velocities of the [Ne III] or [Ne V] emission lines, relative to [Ne II], of more than 200 km s{sup –1}. Furthermore, six starburst and five active galactic nucleus dominated LIRGs show a clear trend of increasing line width with ionization potential

  17. On-line coupling of sample preconcentration by LVSEP with gel electrophoretic separation on T-channel chips.

    Science.gov (United States)

    Kitagawa, Fumihiko; Kinami, Saeko; Takegawa, Yuuki; Nukatsuka, Isoshi; Sueyoshi, Kenji; Kawai, Takayuki; Otsuka, Koji

    2017-01-01

    To achieve an on-line coupling of the sample preconcentration by a large-volume sample stacking with an electroosmotic flow pump (LVSEP) with microchip gel electrophoresis (MCGE), a sample solution, a background solution for LVSEP and a sieving solution for MCGE were loaded in a T-form channel and three reservoirs on PDMS microchips. By utilizing the difference in the flow resistance of the two channels, a low-viscosity sample and a viscous polymer solution were easily introduced into the LVSEP and MCGE channels, respectively. Fluorescence imaging of the sequential LVSEP-MCGE processes clearly demonstrated that a faster stacking of anionic fluorescein and successive introduction into the MCGE channel can be carried out on the T-channel chip. To evaluate the preconcentration performance, a conventional MCZE analysis of fluorescein on the cross-channel chip was compared with LVSEP-MCGE on the short T-channel chip, and as a result that the value of sensitive enhancement factor (SEF) was estimated to be 370. The repeatability of the peak height was good with the RSD value of 3.2%, indicating the robustness of the enrichment performance. In the successive LVSEP-MCGE analysis of φX174/HaeIII digest, the DNA fragments were well enriched to a sharp peak in the LVSEP channel, and they were separated in the MCGE channel, whose electropherogram was well-resembled with that in the conventional MCGE. The values of SEF for the DNA fragments were calculated to be ranging from 74 to 108. Thus, the successive LVSEP-MCGE analysis was effective for both preconcentrating and separating DNA fragments. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Determination of trace thorium in water samples by flow injection fluorescence spectrophotometry with microcolumn on-line preconcentration

    International Nuclear Information System (INIS)

    Shen Zhuqin; Zhang Yanan; Guo Dongfa; Huang Yun

    1991-01-01

    An on-line preconcentration time resolved fluorimetric method was developed for the determination of trace thorium in water, based on luminescence of complex Th-morin-TOPO (or TRPO)-sodium lauryl sulfate in sulfuric acid medium. Interferences from companied cations, such as Al 3+ and Zr 4+ , which emit fluorescence with much slower rising rate at the same condition were effectively eliminated through optimization of the manifold parameters and precisely controlling of the elution flow rate. Effects of nearly 40 ions were also investigated. The detection limit, the liner range and relative standard deviation for 50 ng Th are 2.5 ng/L, 0∼80 ng and 3.6%, respectively. Sampling rate is 30 per hour

  19. Long-Term Monitoring of the Broad-Line Region Properties in a Selected Sample of AGN

    Energy Technology Data Exchange (ETDEWEB)

    Ilić, Dragana [Department of Astronomy, Faculty of Mathematics, University of Belgrade, Belgrade (Serbia); Shapovalova, Alla I. [Special Astrophysical Observatory, Russian Academy of Sciences, Nizhnii Arkhyz (Russian Federation); Popović, Luka Č. [Department of Astronomy, Faculty of Mathematics, University of Belgrade, Belgrade (Serbia); Astronomical Observatory, Belgrade (Serbia); Chavushyan, Vahram [Instituto Nacional de Astrofísica, Óptica y Electrónica, Puebla (Mexico); Burenkov, Alexander N. [Special Astrophysical Observatory, Russian Academy of Sciences, Nizhnii Arkhyz (Russian Federation); Kollatschny, Wolfram [Institut fuer Astrophysik, Universitaet Goettingen, Göttingen (Germany); Kovačević, Andjelka [Department of Astronomy, Faculty of Mathematics, University of Belgrade, Belgrade (Serbia); Marčeta-Mandić, Sladjana [Department of Astronomy, Faculty of Mathematics, University of Belgrade, Belgrade (Serbia); Astronomical Observatory, Belgrade (Serbia); Rakić, Nemanja [Department of Astronomy, Faculty of Mathematics, University of Belgrade, Belgrade (Serbia); Faculty of Science, University of Banjaluka, Banjaluka, Republic of Srpska (Bosnia and Herzegovina); La Mura, Giovanni; Rafanelli, Piero, E-mail: dilic@math.rs [Department of Physics and Astronomy, University of Padova, Padova (Italy)

    2017-09-14

    We present the results of the long-term optical monitoring campaign of active galactic nuclei (AGN) coordinated by the Special Astrophysical Observatory of the Russian Academy of Science. This campaign has produced a remarkable set of optical spectra, since we have monitored for several decades different types of broad-line (type 1) AGN, from a Seyfert 1, double-peaked line, radio loud and radio quiet AGN, to a supermassive binary black hole candidate. Our analysis of the properties of the broad line region (BLR) of these objects is based on the variability of the broad emission lines. We hereby give a comparative review of the variability properties of the broad emission lines and the BLR of seven different type 1 AGNs, emphasizing some important results, such as the variability rate, the BLR geometry, and the presence of the intrinsic Baldwin effect. We are discussing the difference and similarity in the continuum and emission line variability, focusing on what is the impact of our results to the supermassive black hole mass determination from the BLR properties.

  20. Long-Term Monitoring of the Broad-Line Region Properties in a Selected Sample of AGN

    Directory of Open Access Journals (Sweden)

    Dragana Ilić

    2017-09-01

    Full Text Available We present the results of the long-term optical monitoring campaign of active galactic nuclei (AGN coordinated by the Special Astrophysical Observatory of the Russian Academy of Science. This campaign has produced a remarkable set of optical spectra, since we have monitored for several decades different types of broad-line (type 1 AGN, from a Seyfert 1, double-peaked line, radio loud and radio quiet AGN, to a supermassive binary black hole candidate. Our analysis of the properties of the broad line region (BLR of these objects is based on the variability of the broad emission lines. We hereby give a comparative review of the variability properties of the broad emission lines and the BLR of seven different type 1 AGNs, emphasizing some important results, such as the variability rate, the BLR geometry, and the presence of the intrinsic Baldwin effect. We are discussing the difference and similarity in the continuum and emission line variability, focusing on what is the impact of our results to the supermassive black hole mass determination from the BLR properties.

  1. Extreme emission-line galaxies out to z ~ 1 in zCOSMOS. I. Sample and characterization of global properties

    Science.gov (United States)

    Amorín, R.; Pérez-Montero, E.; Contini, T.; Vílchez, J. M.; Bolzonella, M.; Tasca, L. A. M.; Lamareille, F.; Zamorani, G.; Maier, C.; Carollo, C. M.; Kneib, J.-P.; Le Fèvre, O.; Lilly, S.; Mainieri, V.; Renzini, A.; Scodeggio, M.; Bardelli, S.; Bongiorno, A.; Caputi, K.; Cucciati, O.; de la Torre, S.; de Ravel, L.; Franzetti, P.; Garilli, B.; Iovino, A.; Kampczyk, P.; Knobel, C.; Kovač, K.; Le Borgne, J.-F.; Le Brun, V.; Mignoli, M.; Pellò, R.; Peng, Y.; Presotto, V.; Ricciardelli, E.; Silverman, J. D.; Tanaka, M.; Tresse, L.; Vergani, D.; Zucca, E.

    2015-06-01

    Context. The study of large and representative samples of low-metallicity star-forming galaxies at different cosmic epochs is of great interest to the detailed understanding of the assembly history and evolution of low-mass galaxies. Aims: We present a thorough characterization of a large sample of 183 extreme emission-line galaxies (EELGs) at redshift 0.11 ≤ z ≤ 0.93 selected from the 20k zCOSMOS bright survey because of their unusually large emission line equivalent widths. Methods: We use multiwavelength COSMOS photometry, HST-ACS I-band imaging, and optical zCOSMOS spectroscopy to derive the main global properties of star-forming EELGs, such as sizes, stellar masses, star formation rates (SFR), and reliable oxygen abundances using both "direct" and "strong-line" methods. Results: The EELGs are extremely compact (r50 ~ 1.3 kpc), low-mass (M∗ ~ 107-1010 M⊙) galaxies forming stars at unusually high specific star formation rates (sSFR ≡ SFR/M⋆ up to 10-7 yr-1) compared to main sequence star-forming galaxies of the same stellar mass and redshift. At rest-frame UV wavelengths, the EELGs are luminous and show high surface brightness and include strong Lyα emitters, as revealed by GALEX spectroscopy. We show that zCOSMOS EELGs are high-ionization, low-metallicity systems, with median 12+log (O/H) = 8.16 ± 0.21 (0.2 Z⊙) including a handful of extremely metal-deficient (Universe, EELGs are most often found in relative isolation. While only very few EELGs belong to compact groups, almost one third of them are found in spectroscopically confirmed loose pairs or triplets. Conclusions: The zCOSMOS EELGs are galaxies caught in a transient and probably early period of their evolution, where they are efficiently building up a significant fraction of their present-day stellar mass in an ongoing, galaxy-wide starburst. Therefore, the EELGs constitute an ideal benchmark for comparison studies between low- and high-redshift low-mass star-forming galaxies. Full

  2. On-line preconcentration and determination of mercury in biological and environmental samples by cold vapor-atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Ferrua, N.; Cerutti, S.; Salonia, J.A.; Olsina, R.A.; Martinez, L.D.

    2007-01-01

    An on-line procedure for the determination of traces of total mercury in environmental and biological samples is described. The present methodology combines cold vapor generation associated to atomic absorption spectrometry (CV-AAS) with preconcentration of the analyte on a minicolumn packed with activated carbon. The retained analyte was quantitatively eluted from the minicolumn with nitric acid. After that, volatile specie of mercury was generated by merging the acidified sample and sodium tetrahydroborate(III) in a continuous flow system. The gaseous analyte was subsequently introduced via a stream of Ar carrier into the atomizer device. Optimizations of both, preconcentration and mercury volatile specie generation variables were carried out using two level full factorial design (2 3 ) with 3 replicates of the central point. Considering a sample consumption of 25 mL, an enrichment factor of 13-fold was obtained. The detection limit (3σ) was 10 ng L -1 and the precision (relative standard deviation) was 3.1% (n = 10) at the 5 μg L -1 level. The calibration curve using the preconcentration system for mercury was linear with a correlation coefficient of 0.9995 at levels near the detection limit up to at least 1000 μg L -1 . Satisfactory results were obtained for the analysis of mercury in tap water and hair samples

  3. An on-line push/pull perfusion-based hollow-fiber liquid-phase microextraction system for high-performance liquid chromatographic determination of alkylphenols in water samples.

    Science.gov (United States)

    Chao, Yu-Ying; Jian, Zhi-Xuan; Tu, Yi-Ming; Wang, Hsaio-Wen; Huang, Yeou-Lih

    2013-06-07

    In this study, we employed a novel on-line method, push/pull perfusion hollow-fiber liquid-phase microextraction (PPP-HF-LPME), to extract 4-tert-butylphenol, 2,4-di-tert-butylphenol, 4-n-nonylphenol, and 4-n-octylphenol from river and tap water samples; we then separated and quantified the extracted analytes through high-performance liquid chromatography (HPLC). Using this approach, we overcame the problem of fluid loss across the porous HF membrane to the donor phase, permitting on-line coupling of HF-LPME to HPLC. In our PPP-HF-LPME system, we used a push/pull syringe pump as the driving source to perfuse the acceptor phase, while employing a heating mantle and an ultrasonic probe to accelerate mass transfer. We optimized the experimental conditions such as the nature of the HF supported intermediary phase and the acceptor phase, the composition of the donor and acceptor phases, the sample temperature, and the sonication conditions. Our proposed method provided relative standard deviations of 3.1-6.2%, coefficients of determination (r(2)) of 0.9989-0.9998, and limits of detection of 0.03-0.2 ng mL(-1) for the analytes under the optimized conditions. When we applied this method to analyses of river and tap water samples, our results confirmed that this microextraction technique allows reliable monitoring of alkylphenols in water samples.

  4. A New Generation of Thermal Desorption Technology Incorporating Multi Mode Sampling (NRT/DAAMS/Liquid Agent) for Both on and off Line Analysis of Trace Level Airbone Chemical Warfare Agents

    International Nuclear Information System (INIS)

    Roberts, G. M.

    2007-01-01

    A multi functional, twin-trap, electrically-cooled thermal desorption (TD) system (TT24-7) will be discussed for the analysis of airborne trace level chemical warfare agents. This technology can operate in both military environments (CW stockpile, or destruction facilities) and civilian locations where it is used to monitor for accidental or terrorist release of acutely toxic substances. The TD system interfaces to GC, GCMS or direct MS analytical platforms and provides for on-line continuous air monitoring with no sampling time blind spots and within a near real time (NRT) context. Using this technology enables on-line sub ppt levels of agent detection from a vapour sample. In addition to continuous sampling the system has the capacity for off-line single (DAAMS) tube analysis and the ability to receive an external liquid agent injection. The multi mode sampling functionality provides considerable flexibility to the TD system, allowing continuous monitoring of an environment for toxic substances plus the ability to analyse calibration standards. A calibration solution can be introduced via a conventional sampling tube on to either cold trap or as a direct liquid injection using a conventional capillary split/splitless injection port within a gas chromatograph. Low level (linearity) data will be supplied showing the TT24-7 analyzing a variety of CW compounds including free (underivitised) VX using the three sampling modes described above. Stepwise changes in vapor generated agent concentrations will be shown, and this is cross referenced against direct liquid agent introduction, and the tube sampling modes. This technology is in use today in several geographies around the world in both static and mobile analytical laboratories. (author)

  5. FEATURES OF SCIENTIFIC INVESTIGATIONS CONDUCTED IN THE LABORATORIES OF THE DEPARTMENT OF WATER SUPPLY OF MGSU

    OpenAIRE

    Nikitina Irina Nikolaevna; Eremeev Aleksandr Vladimirovich

    2016-01-01

    The article focuses on the work of the laboratories of the Department of Water Supply of MGSU. The laboratory of pipe-lines, pumping equipment and sanitary equipment operates in MGSU affiliated to the department of water supply. A hydraulic stand for testing and defining the the hydraulic characteristics of pressure and free-flow pipelines of water supply and sewerage systems is installed there. There are also stands for investigating the sanitary equipment of the buildings, the fire and hot ...

  6. Measurement of radioactive lines in powdered milk samples in Londrina (Parana State, Brazil) region

    International Nuclear Information System (INIS)

    Melquiades, Fabio Luiz

    2000-01-01

    This work deals with the measurement of radioactive lines in powdered milk, with high resolution gamma spectrometry, using a HPGe detector with relative efficiency of 10%, coupled to the electronic nuclear chain and a multichannel card of 8192 channels. Some tests were realized before beginning the measurements. The first of them was to define the shield to be used, making several measured with different shields according to the available materials, opting finally for a shield composed of bricks of lead (10 cm thickness), plates of iron (4nm thickness) and of aluminum (2 mm thickness). Four different geometries for the samples recipients were tested, and the Marinelli beaker of 2,1 liters totally filled was the one which supplied the best peak/background ratio. A statistical inference was also realized to determine the sampling that represents each one of the lots of milk to be measured, resulting in a number of 6 samples, for a confidence level of 95%. Two different kinds of powdered milk produced at Londrina were analyzed, Integral Powdered Milk Cativa and Integral Powdered Milk Polly. The samples were properly put in the Marinelli beaker of 2,1 L, sealed and kept for 40 days to reach the secular equilibrium. The counting time for each measurement was two days. It was possible to identify the radionuclides 40 K, 137 Cs and 232 Th (from 208 Tl), whose activities were calculated according to the International Atomic Energy Agency norms (IAEA, 1989). The detector efficiency was measured using calibrated samples, prepared with the certified reference materials IAEA-326 and IAEA-375. Corrections for self-absorption were accomplished, based on measures of samples with different densities. The results obtained for the powdered milk Cativa were: 464± 12 Bq/kg for 40 K, 3,46 ± 1,05 and 0,46 ± 1,05 and 0,46 ± 0,16 Bq/kg for the minimum detectable activities of 137 Cs and 232 Th, respectively. For the milk Polly, the results were: 452±10 Bq/kg for 40 K, 3,19 ± 0

  7. An optimized Line Sampling method for the estimation of the failure probability of nuclear passive systems

    International Nuclear Information System (INIS)

    Zio, E.; Pedroni, N.

    2010-01-01

    The quantitative reliability assessment of a thermal-hydraulic (T-H) passive safety system of a nuclear power plant can be obtained by (i) Monte Carlo (MC) sampling the uncertainties of the system model and parameters, (ii) computing, for each sample, the system response by a mechanistic T-H code and (iii) comparing the system response with pre-established safety thresholds, which define the success or failure of the safety function. The computational effort involved can be prohibitive because of the large number of (typically long) T-H code simulations that must be performed (one for each sample) for the statistical estimation of the probability of success or failure. In this work, Line Sampling (LS) is adopted for efficient MC sampling. In the LS method, an 'important direction' pointing towards the failure domain of interest is determined and a number of conditional one-dimensional problems are solved along such direction; this allows for a significant reduction of the variance of the failure probability estimator, with respect, for example, to standard random sampling. Two issues are still open with respect to LS: first, the method relies on the determination of the 'important direction', which requires additional runs of the T-H code; second, although the method has been shown to improve the computational efficiency by reducing the variance of the failure probability estimator, no evidence has been given yet that accurate and precise failure probability estimates can be obtained with a number of samples reduced to below a few hundreds, which may be required in case of long-running models. The work presented in this paper addresses the first issue by (i) quantitatively comparing the efficiency of the methods proposed in the literature to determine the LS important direction; (ii) employing artificial neural network (ANN) regression models as fast-running surrogates of the original, long-running T-H code to reduce the computational cost associated to the

  8. Irreversibility line and magnetic field dependence of the critical current in superconducting MgB sub 2 bulk samples

    CERN Document Server

    Gioacchino, D D; Tripodi, P; Grimaldi, G

    2003-01-01

    The third harmonic components of the ac susceptibility of MgB sub 2 bulk samples have been measured as a function of applied magnetic fields, together with standard magnetization cycles. The irreversibility line (IL) of the magnetic field has been extracted from the onset of the third harmonic components. Using a (1 - t) supalpha glass/liquid best fit where alpha 1.27 IL shows a coherent length xi divergence with exponent nu = 0.63, which indicates a 3D behaviour. Moreover, using the numerical solution of the non-linear magnetic diffusion equation, considering the creep model in a 3D vortex glass, a good description of the vortex dynamics has been obtained. The behaviour of the magnetization amplitude (approx Hz) and the ac susceptibility signals (kHz), at different applied magnetic fields, 3.5 T < H sub d sub c < 4.5 T, and at the reduced temperature 0.86 < t < 0.93 (T = 22 K), shows that the superconducting dynamic response of vortices in the MgB sub 2 samples is not evidently dependent on the f...

  9. Study of the pollution impact from wastewater reuse for irrigation on the groundwater of the quaternary aquifer, west cairo

    International Nuclear Information System (INIS)

    Abd El Samie, S.G.; Ahmed, M.A.; Hassan, H.B.; Hamza, M.S.

    2005-01-01

    The hazards resulting from the extensive application of using sewage and drainage effluent in its form or mixing with fresh water from two sewerage stations(Zenin and Abu-Rawash) for agriculture irrigation were studied by means of chemical, isotopic and biological techniques. The hydrochemical results of major chemical constituents of surface water samples fall in the acceptable range for using this water for irrigation, while minor groups (NO 3 , PO 4 ) and heavy metals measurements showed higher values of Cd, Fe, Ni, Mn, and Pb in the mixed water more than the maximum permissible limits. The collected groundwater samples from the area of study showed high values of the total dissolved solids, minor groups and heavy metals in most wells around Zenin and abu Rawash sewerage stations. These values increase in the direction of the groundwater flow from south-east to north-west. The isotopic enrichment of delta 18 O, delta D enhanced with tritium values for surface and groundwater samples confirms the direct replenishment from surface and groundwater samples confirms the direct replenishment from surface water bodies by downward infiltration to the underlying aquifer, which permits the migration of wastewater contaminants through the soil layers to reach the groundwater level. The influence of wastewater infiltration was also detected from the high counting numbers of microbes obtained in all samples, which selected from some drains and wells close to the sewerage stations. From the previous results the real hazards for using this water not only depend on the quantitative estimates of total major ions, but the harmful pathogenic attack of micro and macro organisms as well as heavy metals will pose the greatest risk to the human health. On the long run the infiltration of the polluted water will threat the groundwater to different depths of the shallow layer of the quaternary aquifer that is the only source of potable water supply in some locations

  10. In-line electrochemical reagent generation coupled to a flow injection biamperometric system for the determination of sulfite in beverage samples.

    Science.gov (United States)

    de Paula, Nattany T G; Barbosa, Elaine M O; da Silva, Paulo A B; de Souza, Gustavo C S; Nascimento, Valberes B; Lavorante, André F

    2016-07-15

    This work reports an in-line electrochemical reagent generation coupled to a flow injection biamperometric procedure for the determination of SO3(2-). The method was based on a redox reaction between the I3(-) and SO3(2-) ions, after the diffusion of SO2 through a gas diffusion chamber. Under optimum experimental conditions, a linear response ranging from 1.0 to 12.0 mg L(-1) (R=0.9999 and n=7), a detection and quantification limit estimated at 0.26 and 0.86 mg L(-1), respectively, a standard deviation relative of 0.4% (n=10) for a reference solution of 4.0 mg L(-1) SO3(2-) and sampling throughput for 40 determinations per hour were achieved. Addition and recovery tests with juice and wine samples were performed resulting in a range between 92% and 110%. There were no significant differences at a 95% confidence level in the analysis of eight samples when comparing the new method with a reference procedure. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Rapid determination of 99Tc in environmental samples by high resolution ICP-MS coupled with on-line flow injection system

    International Nuclear Information System (INIS)

    Kim, C.K.; Kim, C.S.; Rho, B.H.; Lee, J.I.

    2002-01-01

    High resolution inductively coupled plasma mass spectrometry coupled with an on-line flow injection system (FI-HR-ICP-MS) was applied to determine the ultra-trace level 99 Tc in soil. The flow injection system (PrepLab TM ) was composed of two TEVA-Spec R resins, reduced remarkably the sample amounts and the analysis time, compared to the conventional analytical methods. In the flow injection system, Mo and Ru were sufficiently eliminated by using the flow injection system, with the decontamination factors of 1.6 x 10 4 and 9.9 x 10 5 , respectively. With the present method, it was possible to determine ultra-low level of 99 Tc in 3∼6 soil at 3-5 hours of analysis time per sample. The relative standard deviation for each sample was less than 4%. The detection limits for 99 Tc was 85 fg x ml -1 (0.05 mBq x ml -1 ), which was calculated from the three times standard deviation of the count rate of the blank. (author)

  12. On-line technique for preparingand measuring stable carbon isotopeof total dissolved inorganic carbonin water samples ( d13CTDIC

    Directory of Open Access Journals (Sweden)

    S. Inguaggiato

    2005-06-01

    Full Text Available A fast and completely automated procedure is proposed for the preparation and determination of d13C of total inorganic carbon dissolved in water ( d13CTDIC. This method is based on the acidification of water samples transforming the whole dissolved inorganic carbon species into CO2. Water samples are directly injected by syringe into 5.9 ml vials with screw caps which have a pierciable rubber septum. An Analytical Precision «Carbonate Prep System» was used both to flush pure helium into the vials and to automatically dispense a fixed amount of H3PO4. Full-equilibrium conditions between produced CO2 and water are reached at a temperature of 70°C (± 0.1°C in less than 24 h. Carbon isotope ratios (13C/ 12C were measured on an AP 2003 continuous flow mass spectrometer, connected on-line with the injection system. The precision and reproducibility of the proposed method was tested both on aqueous standard solutions prepared using Na2CO3 with d13C=-10.78 per mil versus PDB (1 s= 0.08, n = 11, and at five different concentrations (2, 3, 4, 5 and 20 mmol/l and on more than thirty natural samples. Mean d13CTDIC on standard solution samples is ?10.89 < per mil versus PDB (1 s= 0.18, n = 50, thus revealing both a good analytical precision and reproducibility. A comparison between average d13CTDIC values on a quadruplicate set of natural samples and those obtained following the chemical and physical stripping method highlights a good agreement between the two analytical methods.

  13. Coupled modelling of subsurface water flux for an integrated flood risk management

    Directory of Open Access Journals (Sweden)

    T. Sommer

    2009-07-01

    Full Text Available Flood events cause significant damage not only on the surface but also underground. Infiltration of surface water into soil, flooding through the urban sewer system and, in consequence, rising groundwater are the main causes of subsurface damage. The modelling of flooding events is an important part of flood risk assessment. The processes of subsurface discharge of infiltrated water necessitate coupled modelling tools of both, surface and subsurface water fluxes. Therefore, codes for surface flooding, for discharge in the sewerage system and for groundwater flow were coupled with each other. A coupling software was used to amalgamate the individual programs in terms of mapping between the different model geometries, time synchronization and data exchange. The coupling of the models was realized on two scales in the Saxon capital of Dresden (Germany. As a result of the coupled modelling it could be shown that surface flooding dominates processes of any flood event. Compared to flood simulations without coupled modelling no substantial changes of the surface inundation area could be determined. Regarding sewerage, the comparison between the influx of groundwater into sewerage and the loading due to infiltration by flood water showed infiltration of surface flood water to be the main reason for sewerage overloading. Concurrent rainfalls can intensify the problem. The infiltration of the sewerage system by rising groundwater contributes only marginally to the loading of the sewerage and the distribution of water by sewerage has only local impacts on groundwater rise. However, the localization of risk areas due to rising groundwater requires the consideration of all components of the subsurface water fluxes. The coupled modelling has shown that high groundwater levels are the result of a multi-causal process that occurs before and during the flood event.

  14. Measurement of protein-like fluorescence in river and waste water using a handheld spectrophotometer.

    Science.gov (United States)

    Baker, Andy; Ward, David; Lieten, Shakti H; Periera, Ryan; Simpson, Ellie C; Slater, Malcolm

    2004-07-01

    Protein-like fluorescence intensity in rivers increases with increasing anthropogenic DOM inputs from sewerage and farm wastes. Here, a portable luminescence spectrophotometer was used to investigate if this technology could be used to provide both field scientists with a rapid pollution monitoring tool and process control engineers with a portable waste water monitoring device, through the measurement of river and waste water tryptophan-like fluorescence from a range of rivers in NE England and from effluents from within two waste water treatment plants. The portable spectrophotometer determined that waste waters and sewerage effluents had the highest tryptophan-like fluorescence intensity, urban streams had an intermediate tryptophan-like fluorescence intensity, and the upstream river samples of good water quality the lowest tryptophan-like fluorescence intensity. Replicate samples demonstrated that fluorescence intensity is reproducible to +/- 20% for low fluorescence, 'clean' river water samples and +/- 5% for urban water and waste waters. Correlations between fluorescence measured by the portable spectrophotometer with a conventional bench machine were 0.91; (Spearman's rho, n = 143), demonstrating that the portable spectrophotometer does correlate with tryptophan-like fluorescence intensity measured using the bench spectrophotometer.

  15. Continuous-flow liquid microjunction surface sampling probe connected on-line with high-performance liquid chromatography/mass spectrometry for spatially resolved analysis of small molecules and proteins.

    Science.gov (United States)

    Van Berkel, Gary J; Kertesz, Vilmos

    2013-06-30

    A continuous-flow liquid microjunction surface sampling probe extracts soluble material from surfaces for direct ionization and detection by mass spectrometry. Demonstrated here is the on-line coupling of such a probe with high-performance liquid chromatography/mass spectrometry (HPLC/MS) enabling extraction, separation and detection of small molecules and proteins from surfaces in a spatially resolved (~0.5 mm diameter spots) manner. A continuous-flow liquid microjunction surface sampling probe was connected to a six-port, two-position valve for extract collection and injection to an HPLC column. A QTRAP® 5500 hybrid triple quadrupole linear ion trap equipped with a Turbo V™ ion source operated in positive electrospray ionization (ESI) mode was used for all experiments. The system operation was tested with the extraction, separation and detection of propranolol and associated metabolites from drug dosed tissues, caffeine from a coffee bean, cocaine from paper currency, and proteins from dried sheep blood spots on paper. Confirmed in the tissue were the parent drug and two different hydroxypropranolol glucuronides. The mass spectrometric response for these compounds from different locations in the liver showed an increase with increasing extraction time (5, 20 and 40 s). For on-line separation and detection/identification of extracted proteins from dried sheep blood spots, two major protein peaks dominated the chromatogram and could be correlated with the expected masses for the hemoglobin α and β chains. Spatially resolved sampling, separation, and detection of small molecules and proteins from surfaces can be accomplished using a continuous-flow liquid microjunction surface sampling probe coupled on-line with HPLC/MS detection. Published in 2013. This article is a U.S. Government work and is in the public domain in the USA.

  16. ExSample. A library for sampling Sudakov-type distributions

    Energy Technology Data Exchange (ETDEWEB)

    Plaetzer, Simon

    2011-08-15

    Sudakov-type distributions are at the heart of generating radiation in parton showers as well as contemporary NLO matching algorithms along the lines of the POWHEG algorithm. In this paper, the C++ library ExSample is introduced, which implements adaptive sampling of Sudakov-type distributions for splitting kernels which are in general only known numerically. Besides the evolution variable, the splitting kernels can depend on an arbitrary number of other degrees of freedom to be sampled, and any number of further parameters which are fixed on an event-by-event basis. (orig.)

  17. ExSample. A library for sampling Sudakov-type distributions

    International Nuclear Information System (INIS)

    Plaetzer, Simon

    2011-08-01

    Sudakov-type distributions are at the heart of generating radiation in parton showers as well as contemporary NLO matching algorithms along the lines of the POWHEG algorithm. In this paper, the C++ library ExSample is introduced, which implements adaptive sampling of Sudakov-type distributions for splitting kernels which are in general only known numerically. Besides the evolution variable, the splitting kernels can depend on an arbitrary number of other degrees of freedom to be sampled, and any number of further parameters which are fixed on an event-by-event basis. (orig.)

  18. Remote sampling and analysis of highly radioactive samples in shielded boxes

    International Nuclear Information System (INIS)

    Kirpikov, D.A.; Miroshnichenko, I.V.; Pykhteev, O.Yu.

    2010-01-01

    The sampling procedure used for highly radioactive coolant water is associated with high risk of personnel irradiation and uncontrolled radioactive contamination. Remote sample manipulation with provision for proper radiation shielding is intended for safety enhancement of the sampling procedure. The sampling lines are located in an isolated compartment, a shielded box. Various equipment which enables remote or automatic sample manipulation is used for this purpose. The main issues of development of the shielded box equipment intended for a wider ranger of remote chemical analyses and manipulation techniques for highly radioactive water samples are considered in the paper. There were three principal directions of work: Transfer of chemical analysis performed in the laboratory inside the shielded box; Prevalence of computer-aided and remote techniques of highly radioactive sample manipulation inside the shielded box; and, Increase in control over sampling and determination of thermal-hydraulic parameters of the coolant water in the sampling lines. The developed equipment and solutions enable remote chemical analysis in the restricted volume of the shielded box by using ion-chromatographic, amperometrical, fluorimetric, flow injection, phototurbidimetric, conductometric and potentiometric methods. Extent of control performed in the shielded box is determined taking into account the requirements of the regulatory documents as well as feasibility and cost of the technical adaptation of various methods to the shielded box conditions. The work resulted in highly precise determination of more than 15 indexes of the coolant water quality performed in on-line mode in the shielded box. It averages to 80% of the total extent of control performed at the prototype reactor plants. The novel solutions for highly radioactive sample handling are implemented in the shielded box (for example, packaging, sample transportation to the laboratory, volume measurement). The shielded box is

  19. Automated on-line solid phase extraction coupled to HPLC-APCI-MS detection as a versatile tool for the analysis of phenols in water samples

    International Nuclear Information System (INIS)

    Wissiack, R.

    2001-05-01

    In this work a liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (HPLC-APCI-MS) technique was developed for the determination of phenols and anilines in waste water samples. All relevant parameters were optimized for liquid chromatographic (LC) separation and mass spectrometric (MS) detection. Mass spectrometric detection was used in either negative ionization (NI) or positive ionization (PI) mode, which was depending on the physicochemical properties of the analyte. For screening analysis, full scan mode (SCAN) was used, while selected ion monitoring (SIM) mode of acquisition was used for maximum sensitivity. The optimal interface parameters and solvent compositions were evaluated, which mainly determined the ionization of analytes thus strongly influencing the sensitivity. The quasi-molecular ions were the most abundant signals both for phenols ([M-H]- in NI) and for anilines ([M+H]+ in PI). In general, fragmentation was hardly observed for one-ring phenols. Only fragmentation due to neutral losses of NO, HCl, NH3, CO2, CHO or CO from the functional groups were obtained via collision induced dissociation (CID) in a single quadrupole mass spectrometer. A further source of structural information was the relative intensity of positive and negative ions for one analyte: Only in the case of para-methyl substituted phenols, detection was also possible in positive ionization mode with reasonable sensitivity. In contrast to the phenols, anilines offered somewhat higher structural information due to increased fragmentation through CID, when detected in the positive ionization mode. The main goal of this work was the development of a method for the determination of US EPA priority phenols in different environmental matrices. As highest sensitivity and selectivity was required for this task, a preconcentrating step was necessary, and consequently solid phase extraction (SPE) was coupled on-line to HPLC-APCI-MS. The optimized method allowed the

  20. Random sampling technique for ultra-fast computations of molecular opacities for exoplanet atmospheres

    Science.gov (United States)

    Min, M.

    2017-10-01

    Context. Opacities of molecules in exoplanet atmospheres rely on increasingly detailed line-lists for these molecules. The line lists available today contain for many species up to several billions of lines. Computation of the spectral line profile created by pressure and temperature broadening, the Voigt profile, of all of these lines is becoming a computational challenge. Aims: We aim to create a method to compute the Voigt profile in a way that automatically focusses the computation time into the strongest lines, while still maintaining the continuum contribution of the high number of weaker lines. Methods: Here, we outline a statistical line sampling technique that samples the Voigt profile quickly and with high accuracy. The number of samples is adjusted to the strength of the line and the local spectral line density. This automatically provides high accuracy line shapes for strong lines or lines that are spectrally isolated. The line sampling technique automatically preserves the integrated line opacity for all lines, thereby also providing the continuum opacity created by the large number of weak lines at very low computational cost. Results: The line sampling technique is tested for accuracy when computing line spectra and correlated-k tables. Extremely fast computations ( 3.5 × 105 lines per second per core on a standard current day desktop computer) with high accuracy (≤1% almost everywhere) are obtained. A detailed recipe on how to perform the computations is given.

  1. SAF line analytical chemistry system

    International Nuclear Information System (INIS)

    Gerber, E.W.; Sherrell, D.L.

    1983-10-01

    An analytical chemistry system dedicated to supporting the Secure Automated Fabrication (SAF) line is discussed. Several analyses are required prior to the fuel pellets being loaded into cladding tubes to assure certification requirements will be met. These analyses, which will take less than 15 minutes, are described. The automated sample transport system which will be used to move pellets from the fabriction line to the chemistry area is also described

  2. Comparative performance of fetal goat tongue cell line ZZ-R 127 and fetal porcine kidney cell line LFBK-αvβ6 for Foot-and-mouth disease virus isolation.

    Science.gov (United States)

    Fukai, Katsuhiko; Morioka, Kazuki; Yamada, Manabu; Nishi, Tatsuya; Yoshida, Kazuo; Kitano, Rie; Yamazoe, Reiko; Kanno, Toru

    2015-07-01

    The fetal goat tongue cell line ZZ-R 127 and the fetal porcine kidney cell line LFBK-α(v)β(6) have been reported to have high sensitivity to various Foot-and-mouth disease virus (FMDV) strains. The suitability of ZZ-R 127 cells for FMDV isolation not only from epithelial suspensions but also from other clinical samples has already been confirmed in a previous study. However, to our knowledge, the suitability of LFBK-α(v)β(6) cells has not been evaluated using clinical samples other than epithelial materials. In addition, both cell lines have never been compared, in terms of use for FMDV isolation, under the same conditions. Therefore, in the current study, the virus isolation rates of both cell lines were compared using clinical samples collected from animals infected experimentally with FMDV. Viruses were successfully isolated from clinical samples other than epithelial suspensions for both cell lines. The virus isolation rates for the 2 cell lines were not significantly different. The Cohen kappa coefficients between the virus isolation results for both cell lines were significantly high. Taken together, these results confirmed the suitability of LFBK-α(v)β(6) cells for FMDV isolation from clinical samples other than epithelial suspensions. The levels of susceptibility of both cell lines to FMDV isolation were also confirmed to be almost the same. © 2015 The Author(s).

  3. Radiation treatment of organic substances which are difficult to decompose for utilizing sewage water again. Radiation decomposition of lignin

    International Nuclear Information System (INIS)

    Sekiguchi, Masayuki; Sawai, Taruko; Tanabe, Hiroko

    1996-01-01

    The sewerage model projects utilizing sewage-treated water and the sewerage model project for the future city executed in Tokyo are described. It is important to obtain the treated water which is suitable to purposes by setting up the target for control and reducing the organic contamination which is difficult to decompose. In fiscal year 1995, as to the decomposing treatment of lignin by radiation, the effect of reducing coloring and the influence when actual flowing-in sewage and treated water coexist were examined. The experimental samples were lignin aqueous solution, synthetic sewage and flowing-in sewage, treated water, and the mixture of treated water and synthetic sewage. The measurement of water quality is explained. The γ ray irradiation with a Co-60 source was carried out. The results of respective samples are reported. When total organic carbon was at the level in flowing-in sewage and treated water, irradiation was effective for eliminating coloring. The soluble organic substances which are difficult to decompose were efficiently decomposed by irradiation. (K.I.)

  4. Primary Multidrug Resistant Tuberculosis and Utility of Line Probe Assay for Its Detection in Smear-Positive Sputum Samples in a Tertiary Care Hospital in South India

    Directory of Open Access Journals (Sweden)

    Fahmiya Leena Yacoob

    2016-01-01

    Full Text Available In a high tuberculosis burdened country like India, rapid, cost-effective, and reliable diagnostic tools for tuberculosis are an urgent need of the hour to prevent inappropriate treatment strategies and further spread of resistance. This study aimed to estimate the proportion of new smear-positive tuberculosis cases with primary resistance to rifampicin and/or isoniazid as well as identify the common mutations associated with it. Sputum of 200 newly diagnosed smear-positive cases of 1+ score and above was directly subjected to Line Probe Assay using the GenoType MTBDRplus assay kit. All samples were inoculated onto solid media and 61 samples were inoculated in automated liquid culture also. The Line Probe Assay gave hundred percent interpretable results with 2.5% of the study population showing resistant pattern. Only 1% of the cases were primary multidrug resistant tuberculosis and 1.5% showed isoniazid monoresistance. S531L and C15T were the most common genetic mutations seen for rifampicin and isoniazid resistance, respectively. 40% had absent rpoB wild type 8 band indicating probable silent mutation after clinical correlation. The average turnaround time for Line Probe Assay was far less (3.8 days as compared to solid and liquid cultures (35.6 days and 13.5 days, resp..

  5. Primary Multidrug Resistant Tuberculosis and Utility of Line Probe Assay for Its Detection in Smear-Positive Sputum Samples in a Tertiary Care Hospital in South India.

    Science.gov (United States)

    Yacoob, Fahmiya Leena; Philomina Jose, Beena; Karunakaran Lelitha, Sarada Devi; Sreenivasan, Sreelatha

    2016-01-01

    In a high tuberculosis burdened country like India, rapid, cost-effective, and reliable diagnostic tools for tuberculosis are an urgent need of the hour to prevent inappropriate treatment strategies and further spread of resistance. This study aimed to estimate the proportion of new smear-positive tuberculosis cases with primary resistance to rifampicin and/or isoniazid as well as identify the common mutations associated with it. Sputum of 200 newly diagnosed smear-positive cases of 1+ score and above was directly subjected to Line Probe Assay using the GenoType MTBDRplus assay kit. All samples were inoculated onto solid media and 61 samples were inoculated in automated liquid culture also. The Line Probe Assay gave hundred percent interpretable results with 2.5% of the study population showing resistant pattern. Only 1% of the cases were primary multidrug resistant tuberculosis and 1.5% showed isoniazid monoresistance. S531L and C15T were the most common genetic mutations seen for rifampicin and isoniazid resistance, respectively. 40% had absent rpoB wild type 8 band indicating probable silent mutation after clinical correlation. The average turnaround time for Line Probe Assay was far less (3.8 days) as compared to solid and liquid cultures (35.6 days and 13.5 days, resp.).

  6. An on-line coupling of nanofibrous extraction with column-switching high performance liquid chromatography - A case study on the determination of bisphenol A in environmental water samples.

    Science.gov (United States)

    Háková, Martina; Chocholoušová Havlíková, Lucie; Chvojka, Jiří; Solich, Petr; Šatínský, Dalibor

    2018-02-01

    Polyamide 6 nanofiber polymers were used as modern sorbents for on-line solid phase extraction (SPE) coupled with liquid chromatography. The on-line SPE system was tested for the determination of bisphenol A in river water samples. Polyamide nanofibers were prepared using needleless electrospinning, inserted into a mini-column cartridge (5 × 4.6mm) and coupled with HPLC. The effect of column packing and the amount of polyamide 6 on extraction efficiency was tested and the packing process was optimized. The proposed method was performed using a 50-µL sample injection followed by an on-line nanofibrous extraction procedure. The influence of the washing mobile phase on the retention of bisphenol A during the extraction procedure was evaluated. Ascentis ® Express C18 (10cm × 4.6mm) core-shell column was used as an analytical column. Fluorescence detection wavelengths (λ ex = 225nm and λ em = 320nm) were used for identification and quantification of Bisphenol A in river waters. The linearity was tested in the range from 2 to 500µgL -1 (using nine calibration points). The limits of detection and quantification were 0.6 and 2µgL -1 , respectively. The developed method was successfully used for the determination of bisphenol A in various samples of river waters in the Czech Republic (The Ohře, Labe, Nisa, Úpa, and Opava Rivers). Copyright © 2017 Elsevier B.V. All rights reserved.

  7. A core invasiveness gene signature reflects epithelial-to-mesenchymal transition but not metastatic potential in breast cancer cell lines and tissue samples.

    Directory of Open Access Journals (Sweden)

    Melike Marsan

    Full Text Available INTRODUCTION: Metastases remain the primary cause of cancer-related death. The acquisition of invasive tumour cell behaviour is thought to be a cornerstone of the metastatic cascade. Therefore, gene signatures related to invasiveness could aid in stratifying patients according to their prognostic profile. In the present study we aimed at identifying an invasiveness gene signature and investigated its biological relevance in breast cancer. METHODS & RESULTS: We collected a set of published gene signatures related to cell motility and invasion. Using this collection, we identified 16 genes that were represented at a higher frequency than observed by coincidence, hereafter named the core invasiveness gene signature. Principal component analysis showed that these overrepresented genes were able to segregate invasive and non-invasive breast cancer cell lines, outperforming sets of 16 randomly selected genes (all P<0.001. When applied onto additional data sets, the expression of the core invasiveness gene signature was significantly elevated in cell lines forced to undergo epithelial-mesenchymal transition. The link between core invasiveness gene expression and epithelial-mesenchymal transition was also confirmed in a dataset consisting of 2420 human breast cancer samples. Univariate and multivariate Cox regression analysis demonstrated that CIG expression is not associated with a shorter distant metastasis free survival interval (HR = 0.956, 95%C.I. = 0.896-1.019, P = 0.186. DISCUSSION: These data demonstrate that we have identified a set of core invasiveness genes, the expression of which is associated with epithelial-mesenchymal transition in breast cancer cell lines and in human tissue samples. Despite the connection between epithelial-mesenchymal transition and invasive tumour cell behaviour, we were unable to demonstrate a link between the core invasiveness gene signature and enhanced metastatic potential.

  8. Assessing the quality of sewer pipes

    NARCIS (Netherlands)

    Stanic, N.

    2013-01-01

    Sewerage and urban drainage systems are capital intensive infrastructures characterised by process and structure complexity. For instance, in the Netherlands (2009), the municipalities spent around €1,2 billion on sewerage (or €151/per household/annum) (Walder, 2011). Proper operation and

  9. A Sample of Quasars with Strong Nitrogen Emission Lines from the Sloan Digital Sky Survey

    DEFF Research Database (Denmark)

    Jiang, Linhua; Fan, Xiaohui; Vestergaard, Marianne

    2008-01-01

    We report on 293 quasars with strong NIV] lambda 1486 or NIII] lambda 1750 emission lines (rest-frame equivalent width > 3 \\AA) at 1.7......We report on 293 quasars with strong NIV] lambda 1486 or NIII] lambda 1750 emission lines (rest-frame equivalent width > 3 \\AA) at 1.7...

  10. Conventional and molecular cytogenetics of human non-medullary thyroid carcinoma: characterization of eight cell line models and review of the literature on clinical samples

    International Nuclear Information System (INIS)

    Ribeiro, Franclim Ricardo; Meireles, Ana Margarida; Rocha, Ana Sofia; Teixeira, Manuel Rodrigues

    2008-01-01

    Cell lines are often poorly characterized from a genetic point of view, reducing their usefulness as tumor models. Our purpose was to assess the genetic background of eight commonly used human thyroid carcinoma models and to compare the findings with those reported for primary tumors of the gland. We used chromosome banding analysis and comparative genomic hybridization to profile eight non-medullary thyroid carcinoma cell lines of papillary (TPC-1, FB2, K1 and B-CPAP), follicular (XTC-1) or anaplastic origin (8505C, C643 and HTH74). To assess the representativeness of the findings, we additionally performed a thorough review of cytogenetic (n = 125) and DNA copy number information (n = 270) available in the literature on clinical samples of thyroid carcinoma. The detailed characterization of chromosomal markers specific for each cell line revealed two cases of mistaken identities: FB2 was shown to derive from TPC-1 cells, whereas K1 cells have their origin in cell line GLAG-66. All cellular models displayed genomic aberrations of varying complexity, and recurrent gains at 5p, 5q, 8q, and 20q (6/7 cell lines) and losses at 8p, 13q, 18q, and Xp (4/7 cell lines) were seen. Importantly, the genomic profiles were compatible with those of the respective primary tumors, as seen in the meta-analysis of the existing literature data. We provide the genomic background of seven independent thyroid carcinoma models representative of the clinical tumors of the corresponding histotypes, and highlight regions of recurrent aberrations that may guide future studies aimed at identifying target genes. Our findings further support the importance of routinely performing cytogenetic studies on cell lines, to detect cross-contamination mishaps such as those identified here

  11. QSOs with narrow emission lines

    International Nuclear Information System (INIS)

    Baldwin, J.A.; Mcmahon, R.; Hazard, C.; Williams, R.E.

    1988-01-01

    Observations of two new high-redshift, narrow-lined QSOs (NLQSOs) are presented and discussed together with observations of similar objects reported in the literature. Gravitational lensing is ruled out as a possible means of amplifying the luminosity for one of these objects. It is found that the NLQSOs have broad bases on their emission lines as well as the prominent narrow cores which define this class. Thus, these are not pole-on QSOs. The FWHM of the emission lines fits onto the smoothly falling tail of the lower end of the line-width distribution for complete QSO samples. The equivalent widths of the combined broad and narrow components of the lines are normal for QSOs of the luminosity range under study. However, the NLQSOs do show ionization differences from broader-lined QSOs; most significant, the semiforbidden C III/C IV intensity ratio is unusually low. The N/C abundance ratio in these objects is found to be normal; the Al/C abundance ratio may be quite high. 38 references

  12. The study of selective emission lines from plasma, obtained by evaporating as sample by laser radiation in air and argon media

    International Nuclear Information System (INIS)

    Sufian, A.; Dimitrov, G.

    1993-01-01

    Ultra violet visible emission spectroscopic analysis of a plasma produced through laser interaction with a solid probe in different gaseous atmospheres is conducted. Reported are the effects of air and argon, as enveloping media, on the spectral intensities of some lines. The temperature gradient of the plasma, in different atmosphere, is also plotted. In order to improve the detection limits of individual elements, suggested are the possible areas of illuminating the slit of the spectroscopic from the plasma, in respect of the height, above the sample, when working in different gaseous media. (author)

  13. REAL-TIME CONTROL OF COMBINED SEWER NETWORKS

    Science.gov (United States)

    Real-time control (RTC) is a custom-designed management program for a specific urban sewerage system during a wet-weather event. The function of RTC is to assure efficient operation of the sewerage system and maximum utilization of existing storage capacity, either to fully conta...

  14. Use of environmental isotopes for studying human induced change in groundwater environment in Lahore, Pakistan

    International Nuclear Information System (INIS)

    Ahmad, M.; Akram, W.; Sajjad, M.I.; Rafiq, M.; Tasneem, Azam M.

    2002-01-01

    presently active surface source. In order to confirm the source of nitrate, samples having nitrate more than 45 mg/l were analyzed for δ 15 N(NO 3 ). Values were found ranging from +10.3 to +25.1 per mille. These enriched values show that nitrates are derived from untreated domestic wastes thrown into sewerage drains, open channels, etc. Bacterial contamination of groundwater also proves the penetration from sewerage drains. Penetration of urban recharge was also studied on the basis of δ 13 C data. It was noticed that these values are negatively skewed towards 13 C index of sewerage water confirming the pollution of shallow aquifer by sewerage drains

  15. Calibration of a degassing-emanation line for 222Rn determination in seawater samples

    International Nuclear Information System (INIS)

    Farias, Luciana Aparecida

    2002-01-01

    The purpose of this study is to calibrate a degassing-emanation line and to determine 222 Rn and 226 Ra activity concentrations in seawater samples. This methodology, also called Lucas method, consists in the extraction of radon (originally dissolved in seawater), collection of the gas in a liquid nitrogen cold trap and transfer from the trap to an alpha scintillation cell. Total extraction efficiencies of the 4 degassing-emanation systems were determined by measuring 226 Ra reference solutions. The efficiencies obtained for these 4 systems varied from 21 % to 62%. This work also presents preliminary results of a study carried out in a series of small embayements of Ubatuba, Sao Paulo State-Brazil: Flamengo Bay, Fortaleza Bay, Mar Virado Bay and Ubatuba Bay. Concentration of Rn in excess varied from 0,011 to 0,317 Bq/L for Flamengo Bay, from 0,009 to 0,130 Bq/L for Fortaleza Bay, from 0,018 to 0,050 Bq/L for Mar Virado Bay and from 0,004 to 0,120 Bq/L for Ubatuba Bay. The results obtained for the concentration of 222 Rn in excess in a transect at Flamengo Bay varied from 0,002 to 0,036 Bq/L. Higher concentrations of 222 Rn in excess were obtained in Flamengo Bay, Fortaleza Bay and Ubatuba bay. It was also observed that the concentration of 222 Rn in excess increases with depth, as expected. (author)

  16. IMPACT OF REALIZED IMS SYSTEM IN PRODUCTION AND DISTRIBUTION OF WATER ON QUALITY OF LIFE

    Directory of Open Access Journals (Sweden)

    Gordana Todorović

    2017-03-01

    Full Text Available In this paper from the assessments: the satisfaction of the citizens with the services PUC "Waterworks and Sewerage" and the total time interruption in water supply, appreciating their importance, we carried out the assessment of the implemented IMS PUC "Waterworks and Sewerage" in Kragujevac.

  17. Emission Line Correlations as Diagnostics of Quasar Winds

    Science.gov (United States)

    Sheldon, Keziah; Richards, Gordon

    2018-01-01

    We investigate correlations between UV and optical emission line properties for a sample of z~0.5 SDSS (Sloan Digital Sky Survey) quasars that have recently been observed by HST. The sample is designed to be comparable in luminosity to the existing reverberation mapping (RM) sample, but less biased in terms of their "eigenvector 1" properties. We seek to understand the conditions under which high-ionization emission lines become dominated by a wind. Our analysis takes advantage of spectral decomposition through Independent Component Analysis (ICA) and archival UV HST spectroscopy of SDSS quasars. With these data we will clarify the needs for RM analysis of quasars with wind-dominated emission features.

  18. Two-Dimensional Capillary Electrophoresis with On-Line Sample Preparation and Cyclodextrin Separation Environment for Direct Determination of Serotonin in Human Urine.

    Science.gov (United States)

    Piešťanský, Juraj; Maráková, Katarína; Mikuš, Peter

    2017-10-07

    An advanced two-dimensional capillary electrophoresis method, based on on-line combination of capillary isotachophoresis and capillary zone electrophoresis with cyclodextrin additive in background electrolyte, was developed for effective determination of serotonin in human urine. Hydrodynamically closed separation system and large bore capillaries (300-800 µm) were chosen for the possibility to enhance the sample load capacity, and, by that, to decrease limit of detection. Isotachophoresis served for the sample preseparation, defined elimination of sample matrix constituents (sample clean up), and preconcentration of the analyte. Cyclodextrin separation environment enhanced separation selectivity of capillary zone electrophoresis. In this way, serotonin could be successfully separated from the rest of the sample matrix constituents migrating in capillary zone electrophoresis step so that human urine could be directly (i.e., without any external sample preparation) injected into the analyzer. The proposed method was successfully validated, showing favorable parameters of sensitivity (limit of detection for serotonin was 2.32 ng·mL -1 ), linearity (regression coefficient higher than 0.99), precision (repeatability of the migration time and peak area were in the range of 0.02-1.17% and 5.25-7.88%, respectively), and recovery (ranging in the interval of 90.0-93.6%). The developed method was applied for the assay of the human urine samples obtained from healthy volunteers. The determined concentrations of serotonin in such samples were in the range of 12.4-491.2 ng·mL -1 that was in good agreement with literature data. This advanced method represents a highly effective, reliable, and low-cost alternative for the routine determination of serotonin as a biomarker in human urine.

  19. Design development of robotic system for on line sampling in fuel reprocessing

    International Nuclear Information System (INIS)

    Balasubramanian, G.R.; Venugopal, P.R.; Padmashali, G.K.

    1990-01-01

    This presentation describes the design and developmental work that is being carried out for the design of an automated sampling system for fast reactor fuel reprocessing plants. The plant proposes to use integrated sampling system. The sample is taken across regular process streams from any intermediate hold up pot. A robot system is planned to take the sample from the sample pot, transfer it to the sample bottle, cap the bottle and transfer the bottle to a pneumatic conveying station. The system covers a large number of sample pots. Alternate automated systems are also examined (1). (author). 4 refs., 2 figs

  20. Neonatal line width in deciduous incisors from Neolithic, mediaeval and modern skeletal samples from north-central Poland.

    Science.gov (United States)

    Kurek, Marta; Żądzińska, Elżbieta; Sitek, Aneta; Borowska-Strugińska, Beata; Rosset, Iwona; Lorkiewicz, Wiesław

    2016-01-01

    The neonatal line is usually the first accentuated incremental line visible on the enamel. The prenatal environment significantly contributes to the width of the neonatal line, influencing the pace of reaching post-delivery homeostasis by the newborn's organism. Studies of the enamel of the earliest developing deciduous teeth can provide an insight into the prenatal development and the perinatal conditions of children of past human populations, thus being an additional source contributing to consideration of the influence of prenatal and perinatal factors modifying growth processes. The aim of this study was to examine whether the neonatal line, reflecting the conditions of the prenatal and perinatal environment, differed between the Neolithic, the mediaeval and the modern populations from the Kujawy region in north-central Poland. The material consisted of longitudinally ground sections of 57 human deciduous incisors obtained from children aged 1.0-7.5 years representing three archaeological series from Brześć Kujawski site. All teeth were sectioned in the labio-linqual plane using a diamond blade (Buechler IsoMet 1000). Final specimens were observed with the microscope Delta Optical Evolution 300 at 10× and 40× magnifications. For each tooth, linear measurements of the neonatal line width were performed on its labial surface at the three levels from the cemento-enamel junction. No significant difference was found in the mean neonatal line width depending on the tooth type and archaeological site, although the thickest neonatal line characterised children from the Neolithic series. In all analysed series, the neonatal line width was diversified depending on the child's age at death. The value of Spearman's rank correlation coefficient calculated for the correlation between the child's age at death and the neonatal line width was statistically significant. A clear increase in the width of the neonatal line was thus observed along with a decrease in the child

  1. K Basin sandfilter backwash line characterization project, analytical results for Campaign 20

    International Nuclear Information System (INIS)

    STEEN, F.H.

    1999-01-01

    Sample 112KWBMF was taken from the K West Sandfilter Backwash Pit on June 1 , 1999, and received by 222-S Laboratory on June 2,1999. Analyses were performed on sample 112KWBMF in accordance with Letter of Instruction for K Basins Sandfilter Backwash Line Samples (LOI) in support of the K Basin Sandfilter Backwash Line Characterization Project

  2. Method for Hot Real-Time Sampling of Gasification Products

    Energy Technology Data Exchange (ETDEWEB)

    Pomeroy, Marc D [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-09-29

    The Thermochemical Process Development Unit (TCPDU) at the National Renewable Energy Laboratory (NREL) is a highly instrumented half-ton/day pilot scale plant capable of demonstrating industrially relevant thermochemical technologies from lignocellulosic biomass conversion, including gasification. Gasification creates primarily Syngas (a mixture of Hydrogen and Carbon Monoxide) that can be utilized with synthesis catalysts to form transportation fuels and other valuable chemicals. Biomass derived gasification products are a very complex mixture of chemical components that typically contain Sulfur and Nitrogen species that can act as catalysis poisons for tar reforming and synthesis catalysts. Real-time hot online sampling techniques, such as Molecular Beam Mass Spectrometry (MBMS), and Gas Chromatographs with Sulfur and Nitrogen specific detectors can provide real-time analysis providing operational indicators for performance. Sampling typically requires coated sampling lines to minimize trace sulfur interactions with steel surfaces. Other materials used inline have also shown conversion of sulfur species into new components and must be minimized. Sample line Residence time within the sampling lines must also be kept to a minimum to reduce further reaction chemistries. Solids from ash and char contribute to plugging and must be filtered at temperature. Experience at NREL has shown several key factors to consider when designing and installing an analytical sampling system for biomass gasification products. They include minimizing sampling distance, effective filtering as close to source as possible, proper line sizing, proper line materials or coatings, even heating of all components, minimizing pressure drops, and additional filtering or traps after pressure drops.

  3. PIXE analysis of thin samples

    International Nuclear Information System (INIS)

    Kiss, Ildiko; Koltay, Ede; Szabo, Gyula; Laszlo, S.; Meszaros, A.

    1985-01-01

    Particle-induced X-ray emission (PIXE) multielemental analysis of thin film samples are reported. Calibration methods of K and L X-lines are discussed. Application of PIXE analysis to aerosol monitoring, multielement aerosol analysis is described. Results of PIXE analysis of samples from two locations in Hungary are compared with the results of aerosol samples from Scandinavia and the USA. (D.Gy.)

  4. Effects of push/pull perfusion and ultrasonication on the extraction efficiencies of phthalate esters in sports drink samples using on-line hollow-fiber liquid-phase microextraction.

    Science.gov (United States)

    Chao, Yu-Ying; Lee, Chien-Hung; Chien, Tzu-Yang; Shih, Yu-Hsuan; Lu, Yin-An; Kuo, Ting-Hsuan; Huang, Yeou-Lih

    2013-08-28

    In previous studies, we developed a process, on-line ultrasound-assisted push/pull perfusion hollow-fiber liquid-phase microextraction (UA-PPP-HF-LPME), combining the techniques of push/pull perfusion (PPP) and ultrasonication with hollow-fiber liquid-phase microextraction (HF-LPME), to achieve rapid extraction of acidic phenols from water samples. In this present study, we further evaluated three more-advanced and novel effects of PPP and ultrasonication on the extraction efficiencies of neutral high-molecular-weight phthalate esters (HPAEs) in sports drinks. First, we found that inner-fiber fluid leakage occurs only in push-only perfusion-based and pull-only perfusion-based HF-LPME, but not in the PPP mode. Second, we identified a significant negative interaction between ultrasonication and temperature. Third, we found that the extraction time of the newly proposed system could be shortened by more than 93%. From an investigation of the factors affecting UA-PPP-HF-LPME, we established optimal extraction conditions and achieved acceptable on-line enrichment factors of 92-146 for HPAEs with a sampling time of just 2 min.

  5. Water and steam sampling systems; Provtagningssystem foer vatten och aanga

    Energy Technology Data Exchange (ETDEWEB)

    Hellman, Mats

    2009-10-15

    The supervision of cycle chemistry can be divided into two parts, the sampling system and the chemical analysis. In modern steam generating plants most of the chemical analyses are carried out on-line. The detection limits of these analyzers are pushed downward to the ppt-range (parts per trillion), however the analyses are not more correct than the accuracy of the sampling system. A lot of attention has been put to the analyzers and the statistics to interpret the results but the sampling procedures has gained much less attention. This report aims to give guidance of the considerations to be made regarding sampling systems. Sampling is necessary since most analysis of interesting parameters cannot be carried out in- situ on-line in the steam cycle. Today's on-line instruments for pH, conductivity, silica etc. are designed to meet a water sample at a temperature of 10-30 deg C. This means that the sampling system has to extract a representative sample from the process, transport and cool it down to room temperature without changing the characteristics of the fluid. In the literature research work, standards and other reports can be found. Although giving similar recommendations in most aspects there are some discrepancies that may be confusing. This report covers all parts in the sampling system: Sample points and nozzles; Sample lines; Valves, regulating and on-off; Sample coolers; Temperature, pressure and flow rate control; Cooling water; and Water recovery. On-line analyzers connecting to the sampling system are not covered. This report aims to clarify what guidelines are most appropriate amongst the existing ones. The report should also give guidance to the design of the sampling system in order to achieve representative samples. In addition to this the report gives an overview of the fluid mechanics involved in sampling. The target group of this report is owners and operators of steam generators, vendors of power plant equipment, consultants working in

  6. Rapid and automated on-line solid phase extraction HPLC-MS/MS with peak focusing for the determination of ochratoxin A in wine samples.

    Science.gov (United States)

    Campone, Luca; Piccinelli, Anna Lisa; Celano, Rita; Pagano, Imma; Russo, Mariateresa; Rastrelli, Luca

    2018-04-01

    This study reports a fast and automated analytical procedure based on an on-line SPE-HPLC-MS/MS method for the automatic pre-concentration, clean up and sensitive determination of OTA in wine. The amount of OTA contained in 100μL of sample (pH≅5.5) was retained and concentrated on an Oasis MAX SPE cartridge. After a washing step to remove matrix interferents, the analyte was eluted in back-flush mode and the eluent from the SPE column was diluted through a mixing Tee, using an aqueous solution before the chromatographic separation achieved on a monolithic column. The developed method has been validated according to EU regulation N. 519/2014 and applied for the analysis of 41 red and 17 white wines. The developed method features minimal sample handling, low solvent consumption, high sample throughput, low analysis cost and provides an accurate and highly selective results. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. HOT GAS LINES IN T TAURI STARS

    International Nuclear Information System (INIS)

    Ardila, David R.; Herczeg, Gregory J.; Gregory, Scott G.; Hillenbrand, Lynne A.; Ingleby, Laura; Bergin, Edwin; Bethell, Thomas; Calvet, Nuria; France, Kevin; Brown, Alexander; Edwards, Suzan; Johns-Krull, Christopher; Linsky, Jeffrey L.; Yang, Hao; Valenti, Jeff A.; Abgrall, Hervé; Alexander, Richard D.; Brown, Joanna M.; Espaillat, Catherine; Hussain, Gaitee

    2013-01-01

    For Classical T Tauri Stars (CTTSs), the resonance doublets of N V, Si IV, and C IV, as well as the He II 1640 Å line, trace hot gas flows and act as diagnostics of the accretion process. In this paper we assemble a large high-resolution, high-sensitivity data set of these lines in CTTSs and Weak T Tauri Stars (WTTSs). The sample comprises 35 stars: 1 Herbig Ae star, 28 CTTSs, and 6 WTTSs. We find that the C IV, Si IV, and N V lines in CTTSs all have similar shapes. We decompose the C IV and He II lines into broad and narrow Gaussian components (BC and NC). The most common (50%) C IV line morphology in CTTSs is that of a low-velocity NC together with a redshifted BC. For CTTSs, a strong BC is the result of the accretion process. The contribution fraction of the NC to the C IV line flux in CTTSs increases with accretion rate, from ∼20% to up to ∼80%. The velocity centroids of the BCs and NCs are such that V BC ∼> 4 V NC , consistent with the predictions of the accretion shock model, in at most 12 out of 22 CTTSs. We do not find evidence of the post-shock becoming buried in the stellar photosphere due to the pressure of the accretion flow. The He II CTTSs lines are generally symmetric and narrow, with FWHM and redshifts comparable to those of WTTSs. They are less redshifted than the CTTSs C IV lines, by ∼10 km s –1 . The amount of flux in the BC of the He II line is small compared to that of the C IV line, and we show that this is consistent with models of the pre-shock column emission. Overall, the observations are consistent with the presence of multiple accretion columns with different densities or with accretion models that predict a slow-moving, low-density region in the periphery of the accretion column. For HN Tau A and RW Aur A, most of the C IV line is blueshifted suggesting that the C IV emission is produced by shocks within outflow jets. In our sample, the Herbig Ae star DX Cha is the only object for which we find a P-Cygni profile in the C IV

  8. AUTOMATED ANALYSIS OF AQUEOUS SAMPLES CONTAINING PESTICIDES, ACIDIC/BASIC/NEUTRAL SEMIVOLATILES AND VOLATILE ORGANIC COMPOUNDS BY SOLID PHASE EXTRACTION COUPLED IN-LINE TO LARGE VOLUME INJECTION GC/MS

    Science.gov (United States)

    Data is presented on the development of a new automated system combining solid phase extraction (SPE) with GC/MS spectrometry for the single-run analysis of water samples containing a broad range of organic compounds. The system uses commercially available automated in-line 10-m...

  9. Critical comparison of the on-line and off-line molecularly imprinted solid-phase extraction of patulin coupled with liquid chromatography.

    Science.gov (United States)

    Lhotská, Ivona; Holznerová, Anežka; Solich, Petr; Šatínský, Dalibor

    2017-12-01

    Reaching trace amounts of mycotoxin contamination requires sensitive and selective analytical tools for their determination. Improving the selectivity of sample pretreatment steps covering new and modern extraction techniques is one way to achieve it. Molecularly imprinted polymers as selective sorbent for extraction undoubtedly meet these criteria. The presented work is focused on the hyphenation of on-line molecularly imprinted solid-phase extraction with a chromatography system using a column-switching approach. Making a critical comparison with a simultaneously developed off-line extraction procedure, evaluation of pros and cons of each method, and determining the reliability of both methods on a real sample analysis were carried out. Both high-performance liquid chromatography methods, using off-line extraction on molecularly imprinted polymer and an on-line column-switching approach, were validated, and the validation results were compared against each other. Although automation leads to significant time savings, fewer human errors, and required no handling of toxic solvents, it reached worse detection limits (15 versus 6 μg/L), worse recovery values (68.3-123.5 versus 81.2-109.9%), and worse efficiency throughout the entire clean-up process in comparison with the off-line extraction method. The difficulties encountered, the compromises made during the optimization of on-line coupling and their critical evaluation are presented in detail. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. High-redshift SDSS Quasars with Weak Emission Lines

    DEFF Research Database (Denmark)

    Diamond-Stanic, Aleksandar M.; Fan, Xiaohui; Brandt, W. N.

    2009-01-01

    We identify a sample of 74 high-redshift quasars (z > 3) with weak emission lines from the Fifth Data Release of the Sloan Digital Sky Survey and present infrared, optical, and radio observations of a subsample of four objects at z > 4. These weak emission-line quasars (WLQs) constitute a promine...

  11. Semi-on-line analysis for fast and precise monitoring of bioreaction processes

    DEFF Research Database (Denmark)

    Christensen, L.H.; Marcher, J.; Schulze, Ulrik

    1996-01-01

    Monitoring of substrates and products during fermentation processes can be achieved either by on-line, in situ sensors or by semi-on-line analysis consisting of an automatic sampling step followed by an ex situ analysis of the retrieved sample. The potential risk of introducing time delays...

  12. Unification in the low radio luminosity regime: evidence from optical line emission

    Science.gov (United States)

    Marchã, M. J. M.; Browne, I. W. A.; Jethava, N.; Antón, S.

    2005-08-01

    We address the question of whether or not the properties of all low-luminosity flat spectrum radio sources, not just the obvious BL Lac objects, are consistent with them being the relativistically beamed counterparts of the low radio luminosity radio galaxies (the Fanaroff-Riley type 1, FR I). We have accumulated data on a well-defined sample of low redshift, core-dominated, radio sources all of which have one-sided core-jet structures seen with very long baseline interferometry, just like most BL Lac objects. We first compare the emission-line luminosities of the sample of core-dominated radio sources with a matched sample of FR I radio galaxies. The emission lines in the core-dominated objects are on average significantly more luminous than those in the comparison sample, inconsistent with the simplest unified models in which there is no orientation dependence of the line emission. We then compare the properties of our core-dominated sample with those of a sample of radio-emitting UGC galaxies selected without bias to core strength. The core-dominated objects fit well on the UGC correlation between line emission and radio core strength found by Verdoes Kleijn et al. The results are not consistent with all the objects participating in a simple unified model in which the observed line emission is orientation independent, though they could fit a single, unified model provided that some FR I radio galaxies have emission line regions that become more visible when viewed along the jet axis. However, they are equally consistent with a scenario in which, for the majority of objects, beaming has minimal effect on the observed core luminosities of a large fraction of the FR I population and that intrinsically stronger cores simply give rise to stronger emission lines. We conclude that FR I unification is much more complex than usually portrayed, and models combining beaming with an intrinsic relationship between core and emission line strengths need to be explored.

  13. Development of automobile brake lining using pulverized cow hooves

    Directory of Open Access Journals (Sweden)

    Katsina C. BALA

    2016-06-01

    Full Text Available Asbestos has been used for so long as automobile brake lining material because of its good physical and chemical properties. However, due to the health hazard associated with its handling, it has lost favour and several alternative materials are being increasingly used. Asbestos-free brake lining was developed in this work using pulverized cow hooves along with epoxy resin, barium sulphate, graphite and aluminium oxide. This was with a view to exploiting the characteristics of cow hooves, which are largely discarded as waste materials to replace asbestos which has been found to be carcinogenic. Samples of brake linings were produced using compressive moulding in which the physical and mechanical properties of the samples were studied. The results obtained showed that proper bonding was achieved as the percentage by weight of epoxy resin increased and percentage by weight of pulverized cow hooves decreased. The hardness, compressive strength, coefficient of friction, water and oil absorption, relative density and wear rate of the brake linings were determined and compared with existing brake lining properties. The result indicates that pulverized cow hooves can be used as brake lining material for automobiles.

  14. Trace analysis of halogenated hydrocarbons in gaseous samples by on-line enrichment in an adsorption trap, on-column cold-trapping and capillary gas chromatography. I.Method and instrumentation

    NARCIS (Netherlands)

    Noij, T.H.M.; Fabian, P.; Borchers, R.; Janssen, F.; Cramers, C.A.M.G.; Rijks, J.A.

    1987-01-01

    A method is described for the determination of halocarbons in gaseous samples down to the ppt level (1:1012, v/v), consisting of successive on-line sub-ambient enrichment on an adsorbent, on-column cryofocusing, capillary gas chromatography and electron-capture detection. The quantitative aspects of

  15. K Basin Sandfilter Backwash Line Characterization Project and Analytical Results for Campaign 24

    International Nuclear Information System (INIS)

    STEEN, F.H.

    1999-01-01

    Sample 203KWBMF was taken from the K West Sandfilter Backwash Pit on November 4, 1999 and received by 2224 Laboratory on November 4, 1999. Analyses were performed on sample 203KWBMF in accordance with ''Letter of Instruction for K Basins sandfilter Backwash Line Samples'' (LOI) in support of the K Basin Sandfilter Backwash Line Characterization Project

  16. Absorption lines, Faraday rotation, and magnetic field estimates for QSO absorption-line clouds

    International Nuclear Information System (INIS)

    Kronberg, P.P.; Perry, J.J.

    1982-01-01

    We have estimated the extragalactic component of Faraday rotation for a sample of 37 QSOs for which there is good absorption line data, which we have also analyzed. Statistical evidence is presented which suggests that we have isolated a component of Faraday rotation which is occurring in the absorption clouds of some QSOs

  17. Supercritical fluid extraction as an on-line clean-up technique for determination of riboflavin vitamins in food samples by capillary electrophoresis with fluorimetric detection.

    Science.gov (United States)

    Zougagh, Mohammed; Ríos, Angel

    2008-08-01

    An automatic method for the separation and determination of riboflavin (RF) vitamins (RF, flavin mononucleotide and flavin adenine dinucleotide) in food samples (chicken liver, tablet and powder milk) is proposed. The method is based on the on-line coupling of a supercritical fluid extractor (SFE) with a continuous flow-CE system with guided optical fiber fluorimetric detection (CF-CE-FD). The whole SFE-CF-CE-FD arrangement allowed the automatic treatment of food samples (clean-up of the sample followed by the extraction of the analytes), and the direct introduction of a small volume of the extracted plug to the CE-FD system for the determination of RF vitamins. Fluorescence detection introduced an appropriated sensitivity and contributed to avoid interferences of nonfluorescent polar compounds coming from the matrix samples in the extracted plug. Electrophoretic responses were linear within the 0.05-1 microg/g range, whereas the detection limits of RF vitamins were in the 0.036-0.042 microg/g range. The proposed arrangement opens up interesting prospects for the direct determination of polar analytes in complex samples with a good throughput and high level of automation.

  18. Performance enhancement of the single-phase series active filter by employing the load voltage waveform reconstruction and line current sampling delay reduction methods

    DEFF Research Database (Denmark)

    Senturk, O.S.; Hava, A.M.

    2011-01-01

    This paper proposes the waveform reconstruction method (WRM), which is utilized in the single-phase series active filter's (SAF's) control algorithm, in order to extract the load harmonic voltage component of voltage harmonic type single-phase diode rectifier loads. Employing WRM and the line...... current sampling delay reduction method, a single-phase SAF compensated system provides higher harmonic isolation performance and higher stability margins compared to the system using conventional synchronous-reference-frame-based methods. The analytical, simulation, and experimental studies of a 2.5 k...

  19. Odour emission inventory of German wastewater treatment plants--odour flow rates and odour emission capacity.

    Science.gov (United States)

    Frechen, F-B

    2004-01-01

    Wastewater Treatment plants can cause odour emissions that may lead to significant odour annoyance in their vicinity. Thus, over the past 20 years, several measurements were taken of the odour emissions that occur at WWTPs of different sizes, treatment technology, plant design and under different operating conditions. The specific aspects of odour sampling and measurement have to be considered. I presented some of the results of my odour emission measurements 11 years ago. However, it is now necessary to update the figures by evaluating newer measurement results obtained from measurements taken from 1994 to 2003. These are presented in this paper. Also, the paper highlights the odour emission capacity (OEC) measurement technique which characterises liquids and can be used to assess the results achieved by different types of treatment in the liquid phase, e.g. in a sewerage system. In addition, the OEC is a suitable parameter to set standards for the odorant content of industrial wastewaters that are discharged into the publicly owned sewerage system.

  20. Private Water Projects

    OpenAIRE

    Izaguirre, Ada Karina; Hunt, Catherine

    2005-01-01

    Drawing on the World Bank's Private Participation in Infrastructure Project Database, this Note reviews developments in the water and sewerage sector of developing countries in 2004 and changes in private participation in the sector since 2001. Data for 2004 show that total investment in water and sewerage projects with private participation amounted to nearly US$2 billion. Recent private ...

  1. Considerations in applying on-line IC techniques to BWR's

    International Nuclear Information System (INIS)

    Kaleda, R.J.

    1992-01-01

    Ion-Chromatography (IC) has moved from its traditional role as a laboratory analytical tool to a real time, dynamic, on-line measurement device to follow ppb and sub-ppb concentrations of deleterious impurities in nuclear power plants. Electric Power Research Institute (EPRI), individual utilities, and industry all have played significant roles in effecting the transition. This paper highlights considerations and the evolution in current on-line Ion Chromatography systems. The first applications of on-line techniques were demonstrated by General Electric (GE) under EPRI sponsorship at Rancho Seco (1980), Calvert Cliffs, and McGuire nuclear units. The primary use was for diagnostic purposes. Today the on-line IC applications have been expanded to include process control and routine plant monitoring. Current on-line IC's are innovative in design, promote operational simplicity, are modular for simplified maintenance and repair, and use field-proven components which enhance reliability. Conductivity detection with electronic or chemical suppression and spectrometric detection techniques are intermixed in applications. Remote multi-point sample systems have addressed memory effects. Early applications measured ionic species in the part per billion range. Today reliable part per trillion measurements are common for on-line systems. Current systems are meeting the challenge of EPRI guideline requirements. Today's on-line IC's, with programmed sampling systems, monitor fluid streams throughout a power plant, supplying data that can be trended, stored and retrieved easily. The on-line IC has come of age. Many technical challenges were overcome to achieve today's IC

  2. Metrological characterization methods for confocal chromatic line sensors and optical topography sensors

    Science.gov (United States)

    Seppä, Jeremias; Niemelä, Karri; Lassila, Antti

    2018-05-01

    The increasing use of chromatic confocal technology for, e.g. fast, in-line optical topography, and measuring thickness, roughness and profiles implies a need for the characterization of various aspects of the sensors. Single-point, line and matrix versions of chromatic confocal technology, encoding depth information into wavelength, have been developed. Of these, line sensors are particularly suitable for in-line process measurement. Metrological characterization and development of practical methods for calibration and checking is needed for new optical methods and devices. Compared to, e.g. tactile methods, optical topography measurement techniques have limitations related to light wavelength and coherence, optical properties of the sample including reflectivity, specularity, roughness and colour, and definition of optical versus mechanical surfaces. In this work, metrological characterization methods for optical line sensors were developed for scale magnification and linearity, sensitivity to sample properties, and dynamic characteristics. An accurate depth scale calibration method using a single prototype groove depth sample was developed for a line sensor and validated with laser-interferometric sample tracking, attaining (sub)micrometre level or better than 0.1% scale accuracy. Furthermore, the effect of different surfaces and materials on the measurement and depth scale was studied, in particular slope angle, specularity and colour. In addition, dynamic performance, noise, lateral scale and resolution were measured using the developed methods. In the case of the LCI1200 sensor used in this study, which has a 11.3 mm  ×  2.8 mm measurement range, the instrument depth scale was found to depend only minimally on sample colour, whereas measuring steeply sloped specular surfaces in the peripheral measurement area, in the worst case, caused a somewhat larger relative sample-dependent change (1%) in scale.

  3. K basin sandfilter backwash line characterization project, analytical results for campaign 15

    International Nuclear Information System (INIS)

    Steen, F.H.

    1999-01-01

    Sample 183KWBMF was taken from the K West Sandfilter Backwash Pit on August 28, 1998 and received by 222-S Laboratory on August 28, 1998. Analyses were performed in accordance with ''Letter of Instruction for K Basins Sandfilter Backwash Line Samples'' (LOI) in support of the K Basin Sandfilter Backwash Line Characterization Project

  4. On-line hydrogen-isotope measurements of organic samples using elemental chromium: An extension for high temperature elemental-analyzer techniques

    Science.gov (United States)

    Gehre, Matthias; Renpenning, Julian; Gilevska, Tetyana; Qi, Haiping; Coplen, Tyler B.; Meijer, Harro A.J.; Brand, Willi A.; Schimmelmann, Arndt

    2015-01-01

    The high temperature conversion (HTC) technique using an elemental analyzer with a glassy carbon tube and filling (temperature conversion/elemental analysis, TC/EA) is a widely used method for hydrogen isotopic analysis of water and many solid and liquid organic samples with analysis by isotope-ratio mass spectrometry (IRMS). However, the TC/EA IRMS method may produce inaccurate δ2H results, with values deviating by more than 20 mUr (milliurey = 0.001 = 1‰) from the true value for some materials. We show that a single-oven, chromium-filled elemental analyzer coupled to an IRMS substantially improves the measurement quality and reliability for hydrogen isotopic compositions of organic substances (Cr-EA method). Hot chromium maximizes the yield of molecular hydrogen in a helium carrier gas by irreversibly and quantitatively scavenging all reactive elements except hydrogen. In contrast, under TC/EA conditions, heteroelements like nitrogen or chlorine (and other halogens) can form hydrogen cyanide (HCN) or hydrogen chloride (HCl) and this can cause isotopic fractionation. The Cr-EA technique thus expands the analytical possibilities for on-line hydrogen-isotope measurements of organic samples significantly. This method yielded reproducibility values (1-sigma) for δ2H measurements on water and caffeine samples of better than 1.0 and 0.5 mUr, respectively. To overcome handling problems with water as the principal calibration anchor for hydrogen isotopic measurements, we have employed an effective and simple strategy using reference waters or other liquids sealed in silver-tube segments. These crimped silver tubes can be employed in both the Cr-EA and TC/EA techniques. They simplify considerably the normalization of hydrogen-isotope measurement data to the VSMOW-SLAP (Vienna Standard Mean Ocean Water-Standard Light Antarctic Precipitation) scale, and their use improves accuracy of the data by eliminating evaporative loss and associated isotopic fractionation while

  5. On-line hydrogen-isotope measurements of organic samples using elemental chromium: an extension for high temperature elemental-analyzer techniques.

    Science.gov (United States)

    Gehre, Matthias; Renpenning, Julian; Gilevska, Tetyana; Qi, Haiping; Coplen, Tyler B; Meijer, Harro A J; Brand, Willi A; Schimmelmann, Arndt

    2015-01-01

    The high temperature conversion (HTC) technique using an elemental analyzer with a glassy carbon tube and filling (temperature conversion/elemental analysis, TC/EA) is a widely used method for hydrogen isotopic analysis of water and many solid and liquid organic samples with analysis by isotope-ratio mass spectrometry (IRMS). However, the TC/EA IRMS method may produce inaccurate δ(2)H results, with values deviating by more than 20 mUr (milliurey = 0.001 = 1‰) from the true value for some materials. We show that a single-oven, chromium-filled elemental analyzer coupled to an IRMS substantially improves the measurement quality and reliability for hydrogen isotopic compositions of organic substances (Cr-EA method). Hot chromium maximizes the yield of molecular hydrogen in a helium carrier gas by irreversibly and quantitatively scavenging all reactive elements except hydrogen. In contrast, under TC/EA conditions, heteroelements like nitrogen or chlorine (and other halogens) can form hydrogen cyanide (HCN) or hydrogen chloride (HCl) and this can cause isotopic fractionation. The Cr-EA technique thus expands the analytical possibilities for on-line hydrogen-isotope measurements of organic samples significantly. This method yielded reproducibility values (1-sigma) for δ(2)H measurements on water and caffeine samples of better than 1.0 and 0.5 mUr, respectively. To overcome handling problems with water as the principal calibration anchor for hydrogen isotopic measurements, we have employed an effective and simple strategy using reference waters or other liquids sealed in silver-tube segments. These crimped silver tubes can be employed in both the Cr-EA and TC/EA techniques. They simplify considerably the normalization of hydrogen-isotope measurement data to the VSMOW-SLAP (Vienna Standard Mean Ocean Water-Standard Light Antarctic Precipitation) scale, and their use improves accuracy of the data by eliminating evaporative loss and associated isotopic fractionation while

  6. Inexpensive on-line alcohol sensor for fermentation monitoring and control

    Energy Technology Data Exchange (ETDEWEB)

    Birch, S W; Turner, A P.F.; Ashby, R E

    1987-01-01

    An inorganic electrochemical fuel cell sensor was interfaced to a microcomputer and used to measure on-line the alcohol concentration in the off-gas of a fermentor. A calibration curve was obtained for methanol (linear range 0-9 g/l) and ethanol (linear range 0-6 g/l) to relate the alcohol concentration in the fermentor liquid with that in the off-gas. The consumption of methanol in a batch fermentation of the methylotroph Ps.BB1 was monitored (sampling frequency of 5 minutes) and compared with samples taken for off-line analysis by GLC. On-line control of the methanol concentration in a fed-batch fermentation was achieved by proportional and integral control. 24 references.

  7. Study of Bacterial Samples Using Laser Induced Breakdown Spectroscopy

    International Nuclear Information System (INIS)

    Farooq W A; Atif M; Tawfik W; Alsalhi M S; Alahmed Z A; Sarfraz M; Singh J P

    2014-01-01

    Laser-induced breakdown spectroscopy (LIBS) technique has been applied to investigate two different types of bacteria, Escherichia coli (B1) and Micrococcus luteus (B2) deposited on glass slides using Spectrolaser 7000. LIBS spectra were analyzed using spectrolaser software. LIBS spectrum of glass substrate was compared with bacteria spectra. Ca, Mg, Na, K, P, S, Cl, Fe, Al, Mn, Cu, C, H and CN-band appeared in bacterial samples in air. Two carbon lines at 193.02 nm, 247.88 nm and one hydrogen line at 656.28 nm with intensity ratios of 1.9, 1.83 and 1.53 appeared in bacterial samples B1 and B2 respectively. Carbon and hydrogen are the important components of the bio-samples like bacteria and other cancer cells. Investigation on LIBS spectra of the samples in He and Ar atmospheres is also presented. Ni lines appeared only in B2 sample in Ar atmosphere. From the present experimental results we are able to show that LIBS technique has a potential in the identification and discrimination of different types of bacteria. (plasma technology)

  8. Application of the Reverse Line Blot Assay for the Molecular Detection of Theileria and Babesia sp. in Sheep and Goat Blood Samples from Pakistan

    Directory of Open Access Journals (Sweden)

    A Rasul

    2013-06-01

    Full Text Available Background: The present study was designed to detect the presence of tick-borne parasites (Theileria and Babesia spp. in 196 blood samples collected from apparently healthy sheep and goats from two provinces, Punjab and Khyber Pukhtoon Khwa, in Pakistan.Methods: Reverse line blot (RLB assay was applied for the parasitic detection by the amplification of hypervariable V4 region of the 18S ribosomal RNA (rRNA gene. A membrane with covalently linked generic and species specific oligonucleotide probes was used for the hybridization of amplified PCR products.Results: Parasites were detected in 16% of the ruminant blood samples under study. Two Theileria species, T. lestoquardi and T. ovis, were identified in samples. 25, of the total 32, infected animals were from Khyber Pukhtoon Khwa.Conclusion: Sheep were more prone to tick borne haemoprotozans as 81% infected samples were sheep as compared to 19% goats (P > 0.001. Risk factor analysis revealed that male (P = 0.03, ani­mals infested by ticks (P = 0.03 and herd composed of sheep only (P = 0.001 were more infected by blood parasites.

  9. A needle extraction utilizing a molecularly imprinted-sol-gel xerogel for on-line microextraction of the lung cancer biomarker bilirubin from plasma and urine samples.

    Science.gov (United States)

    Moein, Mohammad Mahdi; Jabbar, Dunia; Colmsjö, Anders; Abdel-Rehim, Mohamed

    2014-10-31

    In the present work, a needle trap utilizing a molecularly imprinted sol-gel xerogel was prepared for the on-line microextraction of bilirubin from plasma and urine samples. Each prepared needle could be used for approximately one hundred extractions before it was discarded. Imprinted and non-imprinted sol-gel xerogel were applied for the extraction of bilirubin from plasma and urine samples. The produced molecularly imprinted sol-gel xerogel polymer showed high binding capacity and fast adsorption/desorption kinetics for bilirubin in plasma and urine samples. The adsorption capacity of molecularly imprinted sol-gel xerogel polymer was approximately 60% higher than that of non-imprinted polymer. The effect of the conditioning, washing and elution solvents, pH, extraction time, adsorption capacity and imprinting factor were investigated. The limit of detection and the lower limit of quantification were set to 1.6 and 5nmolL(-1), respectively using plasma or urine samples. The standard calibration curves were obtained within the concentration range of 5-1000nmolL(-1) in both plasma and urine samples. The coefficients of determination values (R(2)) were ≥0.998 for all runs. The extraction recovery was approximately 80% for BR in the human plasma and urine samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Clues to quasar broad-line region geometry and kinematics

    NARCIS (Netherlands)

    Vestergaard, M; Wilkes, BJ; Barthel, PD

    2000-01-01

    We present evidence that the high-velocity C IV lambda 1549 emission-line gas of radio-loud quasars may originate in a disklike configuration, in close proximity to the accretion disk often assumed to emit the low-ionization lines. For a sample of 36 radio-loud z approximate to 2 quasars, we find

  11. Statistical Methods in Assembly Quality Management of Multi-Element Products on Automatic Rotor Lines

    Science.gov (United States)

    Pries, V. V.; Proskuriakov, N. E.

    2018-04-01

    To control the assembly quality of multi-element mass-produced products on automatic rotor lines, control methods with operational feedback are required. However, due to possible failures in the operation of the devices and systems of automatic rotor line, there is always a real probability of getting defective (incomplete) products into the output process stream. Therefore, a continuous sampling control of the products completeness, based on the use of statistical methods, remains an important element in managing the quality of assembly of multi-element mass products on automatic rotor lines. The feature of continuous sampling control of the multi-element products completeness in the assembly process is its breaking sort, which excludes the possibility of returning component parts after sampling control to the process stream and leads to a decrease in the actual productivity of the assembly equipment. Therefore, the use of statistical procedures for continuous sampling control of the multi-element products completeness when assembled on automatic rotor lines requires the use of such sampling plans that ensure a minimum size of control samples. Comparison of the values of the limit of the average output defect level for the continuous sampling plan (CSP) and for the automated continuous sampling plan (ACSP) shows the possibility of providing lower limit values for the average output defects level using the ACSP-1. Also, the average sample size when using the ACSP-1 plan is less than when using the CSP-1 plan. Thus, the application of statistical methods in the assembly quality management of multi-element products on automatic rotor lines, involving the use of proposed plans and methods for continuous selective control, will allow to automating sampling control procedures and the required level of quality of assembled products while minimizing sample size.

  12. On-line analysis of water contamination by organic compounds; On-line-Analytik der Wasserverschmutzung durch organische Substanzen

    Energy Technology Data Exchange (ETDEWEB)

    Wagt, R. van der; Vos, F. de [Skalar Analytical (Netherlands); Babichenko, S.; Poryvkina, L. [Institute of Ecology, Tallinn (Estonia)

    1999-08-01

    In many environmental applications decomposing the mixture of substances in the water into its various chemical ingredients, for subsequent analysis, is a very complicated task. The most productive approach to on-line diagnosis is to treat the object as an integral spectroscopic sample, characterized by certain specific Spectral Fluorescent Signatures (SFS). The SFS are recorded as a matrix of fluorescent intensity of organic compounds in water, in co-ordinates of excitation and emission spectra, providing a three-dimensional spectrum. Spectral windows of SFS are defined by fluorescent characteristics of basic groups of organic substances in the water sample. The novel Skalar Fluo Imager, based on this principle, is intended for the analysis of organic compounds in natural, domestic, and technological waters in an on-line mode. (orig.) [German] In vielen Umweltschutzanwendungen stellt die Auftrennung eines Substanzgemisches zum Zweck der Analyse eine sehr komplizierte Aufgabe dar. Ein erfolgversprechender Ansatz fuer eine on-line-Diagnostik besteht darin, das Objekt als integrale Spektroskopieprobe zu betrachten, die durch bestimmte spezifische Spektral-Fluoreszenz-Signaturen (SFS) charakterisiert wird. Diese werden als Fluoreszenz-Intensitaets-Matrix organischer Verbindungen in Wasser dargestellt, mit Anregungs- und Emissionsspektren als weiteren Koordinaten, wodurch ein dreidimensionales Spektrum entsteht. Spektrale Fenster der SFS sind definiert als Fluoreszenzcharakteristika von Funktionsgruppen organischer Substanzen in der Wasserprobe. Der auf diesem Prinzip basierende Skalar Fluo Imager ist fuer die on-line-Analyse organischer Bestandteile in natuerlichen, Haus- und technischen Waessern gedacht. (orig.)

  13. DISCOVERY OF ULTRA-FAST OUTFLOWS IN A SAMPLE OF BROAD-LINE RADIO GALAXIES OBSERVED WITH SUZAKU

    International Nuclear Information System (INIS)

    Tombesi, F.; Sambruna, R. M.; Mushotzky, R. F.; Reeves, J. N.; Gofford, J.; Braito, V.; Ballo, L.; Cappi, M.

    2010-01-01

    We present the results of a uniform and systematic search for blueshifted Fe K absorption lines in the X-ray spectra of five bright broad-line radio galaxies observed with Suzaku. We detect, for the first time in radio-loud active galactic nuclei (AGNs) at X-rays, several absorption lines at energies greater than 7 keV in three out of five sources, namely, 3C 111, 3C 120, and 3C 390.3. The lines are detected with high significance according to both the F-test and extensive Monte Carlo simulations. Their likely interpretation as blueshifted Fe XXV and Fe XXVI K-shell resonance lines implies an origin from highly ionized gas outflowing with mildly relativistic velocities, in the range v ≅ 0.04-0.15c. A fit with specific photoionization models gives ionization parameters in the range log ξ ≅ 4-5.6 erg s -1 cm and column densities of N H ≅ 10 22 -10 23 cm -2 . These characteristics are very similar to those of the ultra-fast outflows (UFOs) previously observed in radio-quiet AGNs. Their estimated location within ∼0.01-0.3 pc of the central super-massive black hole suggests a likely origin related with accretion disk winds/outflows. Depending on the absorber covering fraction, the mass outflow rate of these UFOs can be comparable to the accretion rate and their kinetic power can correspond to a significant fraction of the bolometric luminosity and is comparable to their typical jet power. Therefore, these UFOs can play a significant role in the expected feedback from the AGN to the surrounding environment and can give us further clues on the relation between the accretion disk and the formation of winds/jets in both radio-quiet and radio-loud AGNs.

  14. Effects of collisions on linear and non-linear spectroscopic line shapes

    International Nuclear Information System (INIS)

    Berman, P.R.

    1978-01-01

    A fundamental physical problem is the determination of atom-atom, atom-molecule and molecule-molecule differential and total scattering cross sections. In this work, a technique for studying atomic and molecular collisions using spectroscopic line shape analysis is discussed. Collisions occurring within an atomic or molecular sample influence the sample's absorptive or emissive properties. Consequently the line shapes associated with the linear or non-linear absorption of external fields by an atomic system reflect the collisional processes occurring in the gas. Explicit line shape expressions are derived characterizing linear or saturated absorption by two-or three-level 'active' atoms which are undergoing collisions with perturber atoms. The line shapes may be broadened, shifted, narrowed, or distorted as a result of collisions which may be 'phase-interrupting' or 'velocity-changing' in nature. Systematic line shape studies can be used to obtain information on both the differential and total active atom-perturber scattering cross sections. (Auth.)

  15. Rational protection of the quality of coastal waters by means of integrated, real-time management of the water environment; Proteccion racional de la calidad de las aguas costeras mediante la gestion integrada y en tiempo real del medio hidrico

    Energy Technology Data Exchange (ETDEWEB)

    Malgrat i Bregolat, P.; Suner Roqueta, D.; Escaler Puigoriol, M. I.; Rivero Moreno, F.

    2005-07-01

    Before the implementation Water Framework directive, it was usual to forget that a good environment protection of the receiving waters needs a correct and coordinated operation of the subsystems of the water cycle, specially sewerage system, WWTP and receiving waters. This explains that most of the countries have focused their efforts in the treatment of dry weather flows forgetting the management of wet weather flows. Actually the idea that a sewerage system or a WWTP can not be planned or managed independently without considering the effects on the receiving waters is commonly accepted because not only each one of these systems must work correctly but also it is required a minimum impact in the receiving waters of the sewerage and WWTP overflows in dry and wet weather. All these links will affect the management strategy of the sewerage system (storm water detection tanks, gates, pumping stations, etc)., the interceptor, the WWTP and the receiving waters. Only an integral planning of the whole water cycle will allow us to get a sustainable environment in the XXI century. Integral management will be important to product the quality of the coastal waters specially in the bathing areas. (Author) 5 refs.

  16. The U-line line balancing problem

    NARCIS (Netherlands)

    Miltenburg, G.J.; Wijngaard, J.

    1994-01-01

    The traditional line balancing (LB) problem considers a production line in which stations are arranged consecutively in a line. A balance is determined by grouping tasks into stations while moving forward (or backward) through a precedence network. Recently many production lines are being arranged

  17. The new Chalk River AMS ion source, sample changer and external sample magazine

    International Nuclear Information System (INIS)

    Koslowsky, V.T.; Bray, N.; Imahori, Y.; Andrews, H.R.; Davies, W.G.

    1997-01-01

    A new sample magazine, sample changer and ion source have been developed and are in routine use at Chalk River. The system features a readily accessible 40-sample magazine at ground potential that is external to the ion source and high-voltage cage. The samples are held in an inert atmosphere and can be individually examined or removed; they can be exchanged en masse as a complete magazine concurrent with an AMS measurement. On-line sample changing is done with a pneumatic rabbit transfer system employing two stages of differential pumping. At Chalk River this is routinely performed across a 200 kV potential. Sample positioning is precise, and hundreds of 36 Cl and 129 I samples have been measured over a period of several days without interruption or alteration of ion source operating conditions. (author)

  18. Incorrect strain information for mouse cell lines: sequential influence of misidentification on sublines.

    Science.gov (United States)

    Uchio-Yamada, Kozue; Kasai, Fumio; Ozawa, Midori; Kohara, Arihiro

    2017-03-01

    Misidentification or cross-contamination of cell lines can cause serious issues. Human cell lines have been authenticated by short tandem repeat profiling; however, mouse cell lines have not been adequately assessed. In this study, mouse cell lines registered with the JCRB cell bank were examined by simple sequence length polymorphism (SSLP) analysis to identify their strains. Based on comparisons with 7 major inbred strains, our results revealed their strains in 80 of 90 cell lines. However, 12 of the 80 cell lines (15%) were found to differ from registered information. Of them, 4 cell lines originated from the same mouse, which had been generated through mating between two different inbred strains. The genotype of the mouse sample had not been examined after the backcross, leading to strain misidentification in those cell lines. Although 8 other cell lines had been established as sublines of a BALB/c cell line, their SSLP profiles are similar to a Swiss cell line. This affects differences in genotypes between inbred and outbred strains. Because the use of inbred samples and interbreeding between strains are not involved in human materials, our results suggest that the cause and influence of misidentification in mouse cell lines are different from those in human.

  19. Searching for the 3.5 keV Line in the Stacked Suzaku Observations of Galaxy Clusters

    Science.gov (United States)

    Bulbul, Esra; Markevitch, Maxim; Foster, Adam; Miller, Eric; Bautz, Mark; Lowenstein, Mike; Randall, Scott W.; Smith, Randall K.

    2016-01-01

    We perform a detailed study of the stacked Suzaku observations of 47 galaxy clusters, spanning a redshift range of 0.01-0.45, to search for the unidentified 3.5 keV line. This sample provides an independent test for the previously detected line. We detect a 2sigma-significant spectral feature at 3.5 keV in the spectrum of the full sample. When the sample is divided into two subsamples (cool-core and non-cool core clusters), the cool-core subsample shows no statistically significant positive residuals at the line energy. A very weak (approx. 2sigma confidence) spectral feature at 3.5 keV is permitted by the data from the non-cool-core clusters sample. The upper limit on a neutrino decay mixing angle of sin(sup 2)(2theta) = 6.1 x 10(exp -11) from the full Suzaku sample is consistent with the previous detections in the stacked XMM-Newton sample of galaxy clusters (which had a higher statistical sensitivity to faint lines), M31, and Galactic center, at a 90% confidence level. However, the constraint from the present sample, which does not include the Perseus cluster, is in tension with previously reported line flux observed in the core of the Perseus cluster with XMM-Newton and Suzaku.

  20. Analysis of hydroxamate siderophores in soil solution using liquid chromatography with mass spectrometry and tandem mass spectrometry with on-line sample preconcentration.

    Science.gov (United States)

    Olofsson, Madelen A; Bylund, Dan

    2015-10-01

    A liquid chromatography with electrospray ionization mass spectrometry method was developed to quantitatively and qualitatively analyze 13 hydroxamate siderophores (ferrichrome, ferrirubin, ferrirhodin, ferrichrysin, ferricrocin, ferrioxamine B, D1 , E and G, neocoprogen I and II, coprogen and triacetylfusarinine C). Samples were preconcentrated on-line by a switch-valve setup prior to analyte separation on a Kinetex C18 column. Gradient elution was performed using a mixture of an ammonium formate buffer and acetonitrile. Total analysis time including column conditioning was 20.5 min. Analytes were fragmented by applying collision-induced dissociation, enabling structural identification by tandem mass spectrometry. Limit of detection values for the selected ion monitoring method ranged from 71 pM to 1.5 nM with corresponding values of two to nine times higher for the multiple reaction monitoring method. The liquid chromatography with mass spectrometry method resulted in a robust and sensitive quantification of hydroxamate siderophores as indicated by retention time stability, linearity, sensitivity, precision and recovery. The analytical error of the methods, assessed through random-order, duplicate analysis of soil samples extracted with a mixture of 10 mM phosphate buffer and methanol, appears negligible in relation to between-sample variations. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. An Advanced Actuator Line Method for Wind Energy Applications and Beyond

    Energy Technology Data Exchange (ETDEWEB)

    Churchfield, Matthew J.; Schreck, Scott; Martinez-Tossas, Luis A.; Meneveau, Charles; Spalart, Philippe R.

    2017-01-09

    The actuator line method to represent rotor aerodynamics within computational fluid dynamics has been in use for over a decade. This method applies a body force to the flow field along rotating lines corresponding to the individual rotor blades and employs tabular airfoil data to compute the force distribution. The actuator line method is attractive because compared to blade-resolved simulations, the required mesh is much simpler and the computational cost is lower. This work proposes a higher fidelity variant of the actuator line method meant to fill the space between current actuator line and blade-resolved simulations. It contains modifications in two key areas. The first is that of freestream velocity vector estimation along the line, which is necessary to compute the lift and drag along the line using tabular airfoil data. Most current methods rely on point sampling in which the location of sampling is ambiguous. Here we test a velocity sampling method that uses a properly weighted integral over space, removing this ambiguity. The second area of improvement is the function used to project the one-dimensional actuator line force onto the three-dimensional fluid mesh as a body force. We propose and test a projection function that spreads the force over a region that looks something like a real blade with the hope that it will produce the blade local and near wake flow features with more accuracy and higher fidelity. Our goal is that between these two improvements, not only will the flow field predictions be enhanced, but also the spanwise loading will be made more accurate. We refer to this combination of improvements as the advanced actuator line method. We apply these improvements to two different wind turbine cases. Although there is a strong wind energy motivation in our work, there is no reason these advanced actuator line ideas cannot be used in other applications, such as helicopter rotors.

  2. Flow injection on-line oxidizing fluorometry coupled to dialysis sampling for the study of carbamazepine-protein binding

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Zhiqi [School of Chemistry and Materials Science, Shaanxi Normal University, Xi' an 710062 (China)]. E-mail: zqzhang@snnu.edu.cn; Liang Guoxi [School of Chemistry and Materials Science, Shaanxi Normal University, Xi' an 710062 (China)

    2005-04-22

    The mechanism of binding of carbamazepine (CBZ) with bovine serum albumin (BSA) has been investigated in vitro based on a new flow injection fluorometry coupled to the technique of dialysis sampling. The CBZ and BSA were mixed in different molar ratios in 0.050 mol L{sup -1} phosphate buffer (containing 0.9% NaCl), pH 7.4, and incubated at 37 {+-} 0.5 deg. C in a water bath. The dialysis sampler was utilized to sample free CBZ from mixed solution with a relative dialytic efficiency of 7.6%. Then the CBZ in dialysis solution was injected into carrier and on-line oxidized by lead dioxide solid-phase reactor into fluorescent product with a maximum excitation wavelength of 355 nm and a maximum emission wavelength of 478 nm. The fluorescence intensity measured was linear proportional with the concentration of free CBZ in mixed solution over the range of 1 x 10{sup -5} to 2 x 10{sup -4} mol L{sup -1} with the detection limit of 6 x 10{sup -6} mol L{sup -1}. According to the fluorescence measurement results from mixed solution, the association constant (K) estimated for CBZ-BSA binding and the number of the binding site (n) with Scatchard analysis were 1.08 x 10{sup 4} L mol{sup -1} and 0.94, respectively. Stern-Volmer plots indicated the presence of dynamic component in the quenching mechanism. The acting force was suggested to be mainly hydrophobic and the distance between the acceptor and donor was 3.12 nm. The estimated binding parameters agreed well with literature values.

  3. Comparison of radiosensitivity between human hematopoietic cell lines derived from patients with Down's syndrome and from normal persons

    International Nuclear Information System (INIS)

    Huang, C.C.; Banerjee, A.; Tan, J.C.; Hou, Y.

    1977-01-01

    Seven hematopoietic cell lines, four derived from the peripheral blood of patients with Down's syndrome (DS) and three from normal persons, were irradiated with 100, 150, 300, and 500 rads from a 60 Co source and harvested for cell count and chromosome aberration studies every 12 hours for 72 hours post irradiation. Cell growth inhibition and an increase in chromosome aberration were observed in all the cell lines at each dose level and time interval. No significant difference was observed in the effects between DS and normal cell lines. The most common types of aberrations in the 12-hour samples were chromosome and/or chromatid breaks. In the later samples, chromatid exchanges were predominant. The results of the variance analyses on the induced chromosome aberrations in six lines (three DS and three normal lines) showed radiation dosage to be the largest component of total variance, following postirradiation duration and cell lines. The samples harvested 24 and 36 hours post irradiation generally showed greater effects than the samples of other harvest durations. The cell line variance could only be attributed to the differences among and between individual cell lines rather than the difference between DS and normal cell lines

  4. A femoral arteriovenous shunt facilitates arterial whole blood sampling in animals

    International Nuclear Information System (INIS)

    Weber, Bruno; Burger, Cyrill; Buck, Alfred; Biro, Peter

    2002-01-01

    In this study we evaluated on-line continuous blood sampling in a femoral arteriovenous (a-v) shunt for use in quantitative tracer studies using gamma-emitting radionuclides in animals. The shunt consisted of 40 cm polyethylene tubing (PE-50) guided through a coincidence probe. Two three-way valves allowed blood pressure measurements and tracer injection. Blood flow in the shunt and the impulse response function (IRF) were assessed using heparinized human blood mixed with fluorine-18 fluorodeoxyglucose (FDG). In vivo experiments were performed in eight male rats (300-350 g) anaesthetized with halothane. In three rats, manual blood sampling was performed in parallel with on-line sampling. In another five animals, the arterial whole blood activity was recorded on-line for 40 min. For the experiments 150-180 MBq FDG was injected over 35 s. Blood flow in the shunt was 23.6, 29.2 and 42.8 ml/h at 100, 120 and 160 mmHg, respectively. The IRF was characterized by minimal dispersion (1-2 s FWHM). Deconvolution of the measured arterial input curves with the IRF changed the measured curve only minimally. Whole blood radioactivity concentration derived from manual and on-line sampling were in excellent agreement. The curves derived from on-line sampling were of high statistical quality. In conclusion, a femoral a-v shunt allows multiple manipulations such as measurement of the arterial whole blood activity, continuous blood pressure monitoring, injection of the tracer and collection of blood samples if necessary. It is not associated with blood loss if the collection of blood samples is not required. It is more convenient to use than manual sampling, the peak of the input curve is never missed and the input curves are of high statistical quality. (orig.)

  5. Rapid and stream-lined methods for analysis of actinides in environmental samples

    International Nuclear Information System (INIS)

    Cooper, E.L.

    2001-01-01

    Full text: 1) Project Summary: A systematic study of separating the actinides from each other in 1 M hydrochloric acid media has been carried out using selective oxidation/reduction processes followed by co-precipitation with neodymium fluoride. We have optimized two such procedures, one with bromate and another with permanganate, for the sequential separation of Am, Pu, Np, and U isotopes. The first procedure involves oxidation of Pu, Np and U to +6 state in 1 M HCI media at 85 deg C with 30% NaBrO 3 and separation from trivalent Am by collecting the latter on the first NdF 3 co- precipitated source. Plutonium is then reduced and converted to +4 oxidation state with 40% NaNO 2 at 85 deg C, while Np and U are kept oxidized with additional bromate in solution at 50-70 deg C, thus separating Pu by collection on a second NdF 3 source. At this stage, Np present in the filtrate is reduced with hydroxylamine hydrochloride and separated from U by collecting on a third source. Subsequently, U is reduced with 30% TiCI 3 and co-precipitated on a final source. The second procedure, which employs KMnO 4 in 1 M HCI media at 60-85 deg C for oxidizing Pu, Np and U, and separating from Am, produces MnO 2 which is collected along with Am on the co-precipitated NdF 3 . This MnO 2 is dissolved on the filter itself with 1 ml of acidified 1.5% H 2 O 2 without any degradation of the α-spectra. After evaporating the filtrate to destroy H 2 O 2 , Pu, Np and U are separated by following steps similar to those in the bromate procedure. The recoveries of the actinides with both procedures are >99%. The decontamination factors are between 10 3 and 10 4 . 2) Summary of Proposed Work for the Next Year: Now that the separation procedure has been developed, we will begin to incorporate it into rapid and steam-lined procedures for samples, such as water, air filters and environmental materials. (author)

  6. Proposals for future activities agreed upon at the seminar on wastewater treatment in urban areas

    International Nuclear Information System (INIS)

    1987-01-01

    The programme of the seminar was divided into three different sections: - Sewerage systems, - Discharge of industrial wastewater to municipal sewerage systems, - Reduction of nitrogen. For each subject the participants of the seminar agreed upon the following proposal for future activities: Sewerage systems: a) Combined sewer overflows (CSO). Brief state-of-the-art reports should be compiled by the Contracting Parties. The reports should provide information on: - extent of combined sewers (in % of sewered area), - design practices including flow equalization, - rates of inflow/infiltration, - pollution due to CSO, - current research, - trends. A compilation of these reports may hopefully lead to the derivation of suitable effluent standards, which may be expressed as frequencies, total volumes or total amount of pollution load. The effluent standards may be expressed as monthly to yearly values

  7. Extensive Sampling of Forest Carbon using High Density Power Line Lidar

    Science.gov (United States)

    Hampton, H. M.; Chen, Q.; Dye, D. G.; Hungate, B. A.

    2013-12-01

    Estimating carbon sequestration and greenhouse gas emissions from forest management, natural processes, and disturbance is of growing interest for mitigating global warming. Ponderosa pine is common at mid-elevations throughout the western United States and is a dominant tree species in southwestern forests. Existing unmanaged "relict" sites and stand reconstructions of southwestern ponderosa pine forests from before European settlement (late 1800s) provide evidence of forests of larger trees of lower density and less vulnerability to severe fires than today's typical conditions of high densities of small trees that have resulted from a century of fire suppression. Forest treatments to improve forest health in the region include tree cutting focused on small-diameter trees (thinning), low-intensity prescribed burning, and monitoring rather than suppressing wildfires. Stimulated by several uncharacteristically-intense fires in the last decade, a collaborative process found strong stakeholder agreement to accelerate forest treatments to reduce fire risk and restore ecological conditions. Land use planning to ramp up management is underway and could benefit from quick and inexpensive techniques to inventory tree-level carbon because existing inventory data are not adequate to capture the range of forest structural conditions. Our approach overcomes these shortcomings by employing recent breakthroughs in estimating aboveground biomass from high resolution light detection and ranging (lidar) remote sensing. Lidar is an active remote sensing technique, analogous to radar, which measures the time required for a transmitted pulse of laser light to return to the sensor after reflection from a target. Lidar data can capture 3-dimensional forest structure with greater detail and broader spatial coverage than is feasible with conventional field measurements. We developed a novel methodology for extensive sampling and field validation of forest carbon, applicable to managed and

  8. [Cultivation of a permanent fish cell line in serum-free media special experiences with a cytotoxicity test for waste water samples

    Science.gov (United States)

    Kohlpoth, Martin; Rusche, Brigitte

    1997-01-01

    The use of fetal calf serum (FCS) as standard medium additive for the cell cultivation must be regarded critically from the point of view of animal welfare as well as for scientific reasons and makes it necessary to look for alternatives. In the last years an in vitro cytotoxicity assay for the testing of industrial waste waters with the permanent fish cell line RTG-2 was established and pre-validated as an alternative to the fish test with the golden orfe. The application of FCS is also a special problem with regard to the testing of waste waters in a cytotoxicity test so that FCS-alternatives were tested. The RTG-2 cells were successfully adapted to the two solvents Basal Medium Supplement (BMS) and Ultroser-G (U-G) that are used to replace serum. The characterisation of these adapted cell lines showed no significant differences in growth rate, adhesion rate, viability and sensitivity to chemicals in comparison to the original RTG-2 cells. On the determination of the cytotoxicity of industrial waste waters the RTG-2 cells adapted to the BMS medium indicated a clearly higher toxicity of the waste water samples than the original RTG-2 cells. This result confirms the thesis that serum components react with waste water elements and thus change the bio-availability of toxic compounds.

  9. Transverse--Harris--lines in a skeletal population from the 1711 Danish plague site

    DEFF Research Database (Denmark)

    Fiscella, Gabriela N; Bennike, Pia; Lynnerup, Niels

    2008-01-01

    This study examines the occurrence and distribution of transverse lines in skeletal remains from the Copenhagen site, a plague cemetery dated 1711 AD. A relatively low frequency for evidence of line formation was observed in the individuals comprising the total sample and no transverse lines were...

  10. On-line stable isotope measurements during plant and soil gas exchange

    International Nuclear Information System (INIS)

    Yakir, D.

    2001-01-01

    Recent techniques for on-line stable isotope measurements during plant and soil exchange of CO 2 and/or water vapor are briefly reviewed. For CO 2 , these techniques provide means for on-line measurements of isotopic discrimination during CO 2 exchange by leaves in the laboratory and in the field, of isotopic discrimination during soil respiration and during soil-atmosphere CO 2 exchange, and of isotopic discrimination in O 2 during plant respiration. For water vapor, these techniques provide means to measure oxygen isotopic composition of water vapor during leaf transpiration and for the analysis of sub microliter condensed water vapor samples. Most of these techniques involve on-line sampling of CO 2 and water vapor from a dynamic, intact soil or plant system. In the laboratory, these systems also allow on-line isotopic analysis by continuous-flow isotope ratio mass spectrometry. The information obtained with these on-line techniques is becoming increasingly valuable, and often critical, for ecophysiologial research and in the study of biosphere-atmosphere interactions. (author)

  11. Fluidic sampling

    International Nuclear Information System (INIS)

    Houck, E.D.

    1992-01-01

    This paper covers the development of the fluidic sampler and its testing in a fluidic transfer system. The major findings of this paper are as follows. Fluidic jet samples can dependably produce unbiased samples of acceptable volume. The fluidic transfer system with a fluidic sampler in-line will transfer water to a net lift of 37.2--39.9 feet at an average ratio of 0.02--0.05 gpm (77--192 cc/min). The fluidic sample system circulation rate compares very favorably with the normal 0.016--0.026 gpm (60--100 cc/min) circulation rate that is commonly produced for this lift and solution with the jet-assisted airlift sample system that is normally used at ICPP. The volume of the sample taken with a fluidic sampler is dependant on the motive pressure to the fluidic sampler, the sample bottle size and on the fluidic sampler jet characteristics. The fluidic sampler should be supplied with fluid having the motive pressure of the 140--150 percent of the peak vacuum producing motive pressure for the jet in the sampler. Fluidic transfer systems should be operated by emptying a full pumping chamber to nearly empty or empty during the pumping cycle, this maximizes the solution transfer rate

  12. Detector Sampling of Optical/IR Spectra: How Many Pixels per FWHM?

    Science.gov (United States)

    Robertson, J. Gordon

    2017-08-01

    Most optical and IR spectra are now acquired using detectors with finite-width pixels in a square array. Each pixel records the received intensity integrated over its own area, and pixels are separated by the array pitch. This paper examines the effects of such pixellation, using computed simulations to illustrate the effects which most concern the astronomer end-user. It is shown that coarse sampling increases the random noise errors in wavelength by typically 10-20 % at 2 pixels per Full Width at Half Maximum, but with wide variation depending on the functional form of the instrumental Line Spread Function (i.e. the instrumental response to a monochromatic input) and on the pixel phase. If line widths are determined, they are even more strongly affected at low sampling frequencies. However, the noise in fitted peak amplitudes is minimally affected by pixellation, with increases less than about 5%. Pixellation has a substantial but complex effect on the ability to see a relative minimum between two closely spaced peaks (or relative maximum between two absorption lines). The consistent scale of resolving power presented by Robertson to overcome the inadequacy of the Full Width at Half Maximum as a resolution measure is here extended to cover pixellated spectra. The systematic bias errors in wavelength introduced by pixellation, independent of signal/noise ratio, are examined. While they may be negligible for smooth well-sampled symmetric Line Spread Functions, they are very sensitive to asymmetry and high spatial frequency sub-structure. The Modulation Transfer Function for sampled data is shown to give a useful indication of the extent of improperly sampled signal in an Line Spread Function. The common maxim that 2 pixels per Full Width at Half Maximum is the Nyquist limit is incorrect and most Line Spread Functions will exhibit some aliasing at this sample frequency. While 2 pixels per Full Width at Half Maximum is nevertheless often an acceptable minimum for

  13. Emission line galaxies and active galactic nuclei in WINGS clusters

    Science.gov (United States)

    Marziani, P.; D'Onofrio, M.; Bettoni, D.; Poggianti, B. M.; Moretti, A.; Fasano, G.; Fritz, J.; Cava, A.; Varela, J.; Omizzolo, A.

    2017-03-01

    We present the analysis of the emission line galaxies members of 46 low-redshift (0.04 employing diagnostic diagrams. We examined the emission line properties and frequencies of star-forming galaxies, transition objects, and active galactic nuclei (AGNs: LINERs and Seyferts), unclassified galaxies with emission lines, and quiescent galaxies with no detectable line emission. A deficit of emission line galaxies in the cluster environment is indicated by both a lower frequency, and a systematically lower Balmer emission line equivalent width and luminosity with respect to control samples; this implies a lower amount of ionized gas per unit mass and a lower star formation rate if the source is classified as Hii region. A sizable population of transition objects and of low-luminosity LINERs (≈ 10-20% of all emission line galaxies) are detected among WINGS cluster galaxies. These sources are a factor of ≈1.5 more frequent, or at least as frequent, as in control samples with respect to Hii sources. Transition objects and LINERs in clusters are most affected in terms ofline equivalent width by the environment and appear predominantly consistent with so-called retired galaxies. Shock heating can be a possible gas excitation mechanism that is able to account for observed line ratios. Specific to the cluster environment, we suggest interaction between atomic and molecular gas and the intracluster medium as a possible physical cause of line-emitting shocks. The data whose description is provided in Table B.1, and emission line catalog of the WINGS database are only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (http://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/599/A83

  14. High-resolution H-band spectroscopy of Be stars with SDSS-III/apogee. I. New Be stars, line identifications, and line profiles

    International Nuclear Information System (INIS)

    Chojnowski, S. Drew; Majewski, Steven R.; Hall, Matthew; Beaton, Rachael; Burton, Adam; Damke, Guillermo; Wilson, John; Whelan, David G.; Wisniewski, John P.; Shetrone, Matthew; Eikenberry, Steve; Hasselquist, Sten; Holtzman, Jon A.; Brewington, Howard; Brinkmann, J.; Mészáros, Szabolcs; Nidever, David; Schneider, Donald P.; Zasowski, Gail; Bizyaev, Dmitry

    2015-01-01

    The Apache Point Observatory Galactic Evolution Experiment (APOGEE) has amassed the largest ever collection of multi-epoch, high-resolution (R∼22,500), H-band spectra for B-type emission line (Be) stars. These stars were targeted by APOGEE as telluric standard stars and subsequently identified via visual inspection as Be stars based on H i Brackett series emission or shell absorption in addition to otherwise smooth continua and occasionally non-hydrogen emission features. The 128/238 APOGEE Be stars for which emission had never previously been reported serve to increase the total number of known Be stars by ∼6%. Because the H band is relatively unexplored compared to other wavelength regimes, we focus here on identification of the H-band lines and analysis of the emission peak velocity separations (Δv p ) and emission peak intensity ratios (V/R) of the usually double-peaked H i and non-hydrogen emission lines. H i Br11 emission is found to preferentially form in the circumstellar disks at an average distance of ∼2.2 stellar radii. Increasing Δv p toward the weaker Br12–Br20 lines suggests these lines are formed interior to Br11. By contrast, the observed IR Fe ii emission lines present evidence of having significantly larger formation radii; distinctive phase lags between IR Fe ii and H i Brackett emission lines further supports that these species arise from different radii in Be disks. Several emission lines have been identified for the first time including C i 16895, a prominent feature in the spectra for almost a fifth of the sample and, as inferred from relatively large Δv p compared to the Br11–Br20, a tracer of the inner regions of Be disks. Emission lines at 15760 Å and 16781 Å remain unidentified, but usually appear along with and always have similar line profile morphology to Fe ii 16878. Unlike the typical metallic lines observed for Be stars in the optical, the H-band metallic lines, such as Fe ii 16878, never exhibit any evidence of

  15. The role of graphene-based sorbents in modern sample preparation techniques.

    Science.gov (United States)

    de Toffoli, Ana Lúcia; Maciel, Edvaldo Vasconcelos Soares; Fumes, Bruno Henrique; Lanças, Fernando Mauro

    2018-01-01

    The application of graphene-based sorbents in sample preparation techniques has increased significantly since 2011. These materials have good physicochemical properties to be used as sorbent and have shown excellent results in different sample preparation techniques. Graphene and its precursor graphene oxide have been considered to be good candidates to improve the extraction and concentration of different classes of target compounds (e.g., parabens, polycyclic aromatic hydrocarbon, pyrethroids, triazines, and so on) present in complex matrices. Its applications have been employed during the analysis of different matrices (e.g., environmental, biological and food). In this review, we highlight the most important characteristics of graphene-based material, their properties, synthesis routes, and the most important applications in both off-line and on-line sample preparation techniques. The discussion of the off-line approaches includes methods derived from conventional solid-phase extraction focusing on the miniaturized magnetic and dispersive modes. The modes of microextraction techniques called stir bar sorptive extraction, solid phase microextraction, and microextraction by packed sorbent are discussed. The on-line approaches focus on the use of graphene-based material mainly in on-line solid phase extraction, its variation called in-tube solid-phase microextraction, and on-line microdialysis systems. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Flow injection microfluidic device with on-line fluorescent derivatization for the determination of Cr(III) and Cr(VI) in water samples after solid phase extraction

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Guilong [Key Laboratory of Eco-Environment of Three Gorges Region of Ministry of Education, Chongqing University, Chongqing, 400045 (China); Department of Chemistry, Beijing Key Laboratory of Microanalytical Methods and Instrumentation, Tsinghua University, Beijing, 100084 (China); He, Qiang, E-mail: heqiang0980@163.com [Key Laboratory of Eco-Environment of Three Gorges Region of Ministry of Education, Chongqing University, Chongqing, 400045 (China); Lu, Ying [Department of Mathematics and Physics, Armed Police College, Chengdu, 610213 (China); Huang, Jing [Research Center for Advanced Computation, College of Science, Xihua University, Chengdu, 610039 (China); Lin, Jin-Ming, E-mail: jmlin@mail.tsinghua.edu.cn [Department of Chemistry, Beijing Key Laboratory of Microanalytical Methods and Instrumentation, Tsinghua University, Beijing, 100084 (China)

    2017-02-22

    In this paper, a rapid and simple method using magnetic multi-walled carbon nanotubes (MWCNTS), as a solid-phase extraction (SPE) sorbent, was successfully developed for extraction and preconcentration trace amounts of Cr(III) in water samples. The synthesized magnetic-MWCNTs nanocomposite was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FT-IR), X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD). A rhodamine derivative (R1) was synthesized and characterized as a highly selective and sensitive fluorescent derivatizing agent for Cr(III). After SPE procedure, Cr(III) analysis was performed by flow injection microfluidic chip with on-line fluorescent derivatization and laser-induced fluorescence (LIF) spectroscopy detection. The parameters, which affected the efficiency of the developed method were investigated and optimized. Under the optimized conditions, the method exhibited a linear dynamic range of 0–10.0 nM, with a detection limit of 0.094 nM and an enrichment factor of 38. Furthermore, real water samples were analyzed and good recoveries were obtained from 91.0 to 101.6%. - Graphical abstract: Flow injection microfluidic device with on-line fluorescent derivatization and detection coupled to LIF. - Highlights: • A highly selective and sensitive derivatizing reagent for Cr(III) was synthesized and characterized. • The magnetic-MWCNTs nanocomposite as a SPE sorbent was successfully synthesized and characterized. • A new portable detection system was developed for microfluidic chip FIA platform.

  17. Metal-organic framework MIL-101 as sorbent based on double-pumps controlled on-line solid-phase extraction coupled with high-performance liquid chromatography for the determination of flavonoids in environmental water samples.

    Science.gov (United States)

    Liu, Yue; Hu, Jia; Li, Yan; Li, Xiao-Shuang; Wang, Zhong-Liang

    2016-10-01

    A novel method with high sensitivity for the rapid determination of chrysin, apigenin and luteolin in environment water samples was developed by double-pumps controlled on-line solid-phase extraction (SPE) coupled with high-performance liquid chromatography (HPLC). In the developed technique, metal organic framework MIL-101 was synthesized and applied as a sorbent for SPE. The as-synthesized MIL-101 was characterized by scanning electron microscope, X-ray diffraction spectrometry, thermal gravimetric analysis and micropore physisorption analysis. The MIL-101 behaved as a fast kinetics in the adsorption of chrysin, apigenin and luteolin. On-line SPE of chrysin, apigenin and luteolin was processed by loading a sample solution at a flow rate of 1.0 mL/min for 10 min. The extracted analytes were subsequently eluted into a ZORBAX Bonus-RP analytical column (25 cm long × 4.6 mm i.d.) for HPLC separation under isocratic condition with a mobile phase (MeOH: ACN: 0.02 M H 3 PO 4 = 35:35:30) at a flow rate of 1.0 mL/min. Experimental conditions, including ionic strength, sample pH, sample loading rates, sample loading time and desorption analytes time, were further optimized to obtain efficient preconcentration and high-precision determination of the analytes mentioned above. The method achieved the merits of simplicity, rapidity, sensitivity, wide linear range and high sample throughput. The possible mechanism for the adsorption of flavonoids on MIL-101 was proposed. The developed method has been applied to determine trace chrysin, apigenin and luteolin in a variety of environmental water samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Survey and analysis of line-frequency interference in the CEBAF accelerator

    International Nuclear Information System (INIS)

    Tiefenback, M.G.; Li, Rui.

    1995-01-01

    Feedthrough of interference from the AC power line into accelerator components is a problem which in pulsed accelerators can be reduced by operation synchronous with the AC line. This means of avoiding line-frequency effects is ineffective for continuous wave machines such as the CEBAF accelerator. We have measured line-frequency perturbations at CEBAF both in beam position and energy by using the beam position monitor system as a multiple-channel sampling oscilloscope. Comparing these data against the measured static optics (taken synchronously with the AC line) we have been able to identify point sources of interference, and resolve line-synchronous variations in the beam energy at a level near 0.001%. 3 refs., 2 figs., 1 tab

  19. Using the Properties of Broad Absorption Line Quasars to Illuminate Quasar Structure

    Science.gov (United States)

    Yong, Suk Yee; King, Anthea L.; Webster, Rachel L.; Bate, Nicholas F.; O'Dowd, Matthew J.; Labrie, Kathleen

    2018-06-01

    A key to understanding quasar unification paradigms is the emission properties of broad absorption line quasars (BALQs). The fact that only a small fraction of quasar spectra exhibit deep absorption troughs blueward of the broad permitted emission lines provides a crucial clue to the structure of quasar emitting regions. To learn whether it is possible to discriminate between the BALQ and non-BALQ populations given the observed spectral properties of a quasar, we employ two approaches: one based on statistical methods and the other supervised machine learning classification, applied to quasar samples from the Sloan Digital Sky Survey. The features explored include continuum and emission line properties, in particular the absolute magnitude, redshift, spectral index, line width, asymmetry, strength, and relative velocity offsets of high-ionisation C IV λ1549 and low-ionisation Mg II λ2798 lines. We consider a complete population of quasars, and assume that the statistical distributions of properties represent all angles where the quasar is viewed without obscuration. The distributions of the BALQ and non-BALQ sample properties show few significant differences. None of the observed continuum and emission line features are capable of differentiating between the two samples. Most published narrow disk-wind models are inconsistent with these observations, and an alternative disk-wind model is proposed. The key feature of the proposed model is a disk-wind filling a wide opening angle with multiple radial streams of dense clumps.

  20. Parsec-Scale Radio Structure and Broad Optical Emission Lines in a Complete Sample of 3CR Lobe-dominated Quasars

    Science.gov (United States)

    Hough, D. H.; Vermeulen, R. C.; Readhead, A. C. S.; Cross, L. L.; Barth, E. L.; Yu, L. H.; Beyer, P. J.; Phifer, E. M.

    2002-03-01

    We present results from VLBI observations of 24 of the 25 lobe-dominated quasars (LDQs) in the 3CR complete sample and from optical spectrophotometry of 14 of these objects. The VLBI observations were made with a variety of arrays-most recently the Very Long Baseline Array-at frequencies ranging from 5 to 22 GHz during the period 1981-1997. The optical spectra were obtained with the Hale 200 inch (5 m) telescope at Palomar Observatory, using the blue and red CCDs of the Double Spectrograph, between 1984 and 1992. The radio nuclei range in strength over nearly 3 orders of magnitude, from ~0.9 Jy down to ~3 mJy, and were imaged at typical resolutions of ~0.5-1.0 mas and sensitivities of ~0.1-0.2 mJy beam-1. All 24 LDQs show detectable radio structure in their nuclei. All 19 objects for which VLBI images could be made show one-sided nuclear jets, often several milliarcseconds in length and significantly curved, on the same side of the compact core as the one-sided large-scale jets seen on Very Large Array images. No counterjets were observed; jet-to-counterjet ratios that virtually all exceed ~10 suggest that these objects are all oriented within ~70° to the line of sight. For the 10 sources in which parsec-scale jet speeds could be estimated, the well-defined motions range from orientations, it is more easily accomodated by a restricted range of orientations. Evidence for slower jet speeds and larger apparent bends close to the core support the concept of a ``transition'' zone in the inner few parsecs of these jets. There are significant correlations among the prominences of the cores and jets, relative jet length, maximum jet deflection angles, and variability amplitude, as well as possible trends involving jet speed and strength of compact jet knots; furthermore, these objects tend to exhibit flat-spectrum cores and steep-spectrum jets. These results are all consistent with orientation-dependent relativistic beaming effects and unification of core- and lobe

  1. EMISSION LINES BETWEEN 1 AND 2 keV IN COMETARY X-RAY SPECTRA

    Energy Technology Data Exchange (ETDEWEB)

    Ewing, Ian; Christian, Damian J. [Department of Physics and Astronomy, California State University, 18111 Nordhoff Street, Northridge, CA 91330 (United States); Bodewits, Dennis [Department of Astronomy, University of Maryland, College Park, MD 20742 (United States); Dennerl, Konrad [Max-Planck-Institut fuer extraterrestrische Physik, Postfach 1312, D-85741 Garching Germany (Germany); Lisse, Carey M. [Planetary Exploration Group, Space Department, Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Rd, Laurel, MD 20723 (United States); Wolk, Scott J., E-mail: ian.ewing.794@my.csun.edu, E-mail: daman.christian@csun.edu [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States)

    2013-01-20

    We present the detection of new cometary X-ray emission lines in the 1.0-2.0 keV range using a sample of comets observed with the Chandra X-Ray Observatory and ACIS spectrometer. We have selected five comets from the Chandra sample with good signal-to-noise spectra. The surveyed comets are C/1999 S4 (LINEAR), C/1999 T1 (McNaught-Hartley), 153P/2002 (Ikeya-Zhang), 2P/2003 (Encke), and C/2008 8P (Tuttle). We modeled the spectra with an extended version of our solar wind charge exchange (SWCX) emission model. Above 1 keV, we find Ikeya-Zhang to have strong emission lines at 1340 and 1850 eV which we identify as being created by SWCX lines of Mg XI and Si XIII, respectively, and weaker emission lines at 1470, 1600, and 1950 eV formed by SWCX of Mg XII, Mg XI, and Si XIV, respectively. The Mg XI and XII and Si XIII and XIV lines are detected at a significant level for the other comets in our sample (LS4, MH, Encke, 8P), and these lines promise additional diagnostics to be included in SWCX models. The silicon lines in the 1700-2000 eV range are detected for all comets, but with the rising background and decreasing cometary emission, we caution that these detections need further confirmation with higher resolution instruments.

  2. An Advanced Actuator Line Method for Wind Energy Applications and Beyond: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Churchfield, Matthew; Schreck, Scott; Martinez-Tossas, Luis A.; Meneveau, Charles; Spalart, Philippe R.

    2017-03-24

    The actuator line method to represent rotor aerodynamics within computational fluid dynamics has been in use for over a decade. This method applies a body force to the flow field along rotating lines corresponding to the individual rotor blades and employs tabular airfoil data to compute the force distribution. The actuator line method is attractive because compared to blade-resolved simulations, the required mesh is much simpler and the computational cost is lower. This work proposes a higher fidelity variant of the actuator line method meant to fill the space between current actuator line and blade-resolved simulations. It contains modifications in two key areas. The first is that of freestream velocity vector estimation along the line, which is necessary to compute the lift and drag along the line using tabular airfoil data. Most current methods rely on point sampling in which the location of sampling is ambiguous. Here we test a velocity sampling method that uses a properly weighted integral over space, removing this ambiguity. The second area of improvement is the function used to project the one-dimensional actuator line force onto the three-dimensional fluid mesh as a body force. We propose and test a projection function that spreads the force over a region that looks something like a real blade with the hope that it will produce the blade local and near wake flow features with more accuracy and higher fidelity. Our goal is that between these two improvements, not only will the flow field predictions be enhanced, but also the spanwise loading will be made more accurate. We refer to this combination of improvements as the advanced actuator line method. We apply these improvements to two different wind turbine cases. Although there is a strong wind energy motivation in our work, there is no reason these advanced actuator line ideas cannot be used in other applications, such as helicopter rotors.

  3. Constraints on Black Hole Spin in a Sample of Broad Iron Line AGN

    Science.gov (United States)

    Brenneman, Laura W.; Reynolds, Christopher S.

    2008-01-01

    We present a uniform X-ray spectral analysis of nine type-1 active galactic nuclei (AGN) that have been previously found to harbor relativistically broadened iron emission lines. We show that the need for relativistic effects in the spectrum is robust even when one includes continuum "reflection" from the accretion disk. We then proceed to model these relativistic effects in order to constrain the spin of the supermassive black holes in these AGN. Our principal assumption, supported by recent simulations of geometrically-thin accretion disks, is that no iron line emission (or any associated Xray reflection features) can originate from the disk within the innermost stable circular orbit. Under this assumption, which tends to lead to constraints in the form of lower limits on the spin parameter, we obtain non-trivial spin constraints on five AGN. The spin parameters of these sources range from moderate (a approximates 0.6) to high (a > 0.96). Our results allow, for the first time, an observational constraint on the spin distribution function of local supermassive black holes. Parameterizing this as a power-law in dimensionless spin parameter (f(a) varies as absolute value of (a) exp zeta), we present the probability distribution for zeta implied by our results. Our results suggest 90% and 95% confidence limits of zeta > -0.09 and zeta > -0.3 respectively.

  4. Final Technical Report - In-line Uranium Immunosensor

    International Nuclear Information System (INIS)

    Blake, Diane A.

    2006-01-01

    In this project, personnel at Tulane University and Sapidyne Instruments Inc. developed an in-line uranium immunosensor that could be used to determine the efficacy of specific in situ biostimulation approaches. This sensor was designed to operate autonomously over relatively long periods of time (2-10 days) and was able to provide near real-time data about uranium immobilization in the absence of personnel at the site of the biostimulation experiments. An alpha prototype of the in-line immmunosensor was delivered from Sapidyne Instruments to Tulane University in December of 2002 and a beta prototype was delivered in November of 2003. The beta prototype of this instrument (now available commercially from Sapidyne Instruments) was programmed to autonomously dilute standard uranium to final concentrations of 2.5 to 100 nM (0.6 to 24 ppb) in buffer containing a fluorescently labeled anti-uranium antibody and the uranium chelator, 2,9-dicarboxyl-1,10-phenanthroline. The assay limit of detection for hexavalent uranium was 5.8 nM or 1.38 ppb. This limit of detection is well below the drinking water standard of 30 ppb recently promulgated by the EPA. The assay showed excellent precision; the coefficients of variation (CV's) in the linear range of the assay were less than 5% and CV?s never rose above 14%. Analytical recovery in the immunosensors-based assay was assessed by adding variable known quantities of uranium to purified water samples. A quantitative recovery (93.75% - 108.17%) was obtained for sample with concentrations from 7.5 to 20 nM (2-4.75 ppb). In August of 2005 the sensor was transported to Oak Ridge National Laboratory, for testing of water samples at the Criddle test site (see Wu et al., Environ. Sci. Technol. 40:3978-3985 2006 for a description of this site). In this first on-site test, the in-line sensor was able to accurately detect changes in the concentrations of uranium in effluent samples from this site. Although the absolute values for the uranium

  5. GAME: GAlaxy Machine learning for Emission lines

    Science.gov (United States)

    Ucci, G.; Ferrara, A.; Pallottini, A.; Gallerani, S.

    2018-06-01

    We present an updated, optimized version of GAME (GAlaxy Machine learning for Emission lines), a code designed to infer key interstellar medium physical properties from emission line intensities of ultraviolet /optical/far-infrared galaxy spectra. The improvements concern (a) an enlarged spectral library including Pop III stars, (b) the inclusion of spectral noise in the training procedure, and (c) an accurate evaluation of uncertainties. We extensively validate the optimized code and compare its performance against empirical methods and other available emission line codes (PYQZ and HII-CHI-MISTRY) on a sample of 62 SDSS stacked galaxy spectra and 75 observed HII regions. Very good agreement is found for metallicity. However, ionization parameters derived by GAME tend to be higher. We show that this is due to the use of too limited libraries in the other codes. The main advantages of GAME are the simultaneous use of all the measured spectral lines and the extremely short computational times. We finally discuss the code potential and limitations.

  6. GAME: GAlaxy Machine learning for Emission lines

    Science.gov (United States)

    Ucci, G.; Ferrara, A.; Pallottini, A.; Gallerani, S.

    2018-03-01

    We present an updated, optimized version of GAME (GAlaxy Machine learning for Emission lines), a code designed to infer key interstellar medium physical properties from emission line intensities of UV/optical/far infrared galaxy spectra. The improvements concern: (a) an enlarged spectral library including Pop III stars; (b) the inclusion of spectral noise in the training procedure, and (c) an accurate evaluation of uncertainties. We extensively validate the optimized code and compare its performance against empirical methods and other available emission line codes (pyqz and HII-CHI-mistry) on a sample of 62 SDSS stacked galaxy spectra and 75 observed HII regions. Very good agreement is found for metallicity. However, ionization parameters derived by GAME tend to be higher. We show that this is due to the use of too limited libraries in the other codes. The main advantages of GAME are the simultaneous use of all the measured spectral lines, and the extremely short computational times. We finally discuss the code potential and limitations.

  7. On-line, proximate analysis of ground beef directly at a meat grinder outlet.

    Science.gov (United States)

    Isaksson, T; Nilsen, B N; Tøgersen, G; Hammond, R P; Hildrum, K I

    1996-07-01

    The fat, moisture and protein contents of ground beef were determined on-line by a diffuse reflectance near infrared (NIR) spectroscopy instrument at the outlet of a meat grinder. Beef samples in the range of 6.2-21.7% fat, 59.6-72.9% moisture and 18.1-20.7% protein were studied. Calibrations from samples ground with hole diameters of 4, 8, 13 or 19 mm in the grinder plate were validated. In addition, calibrations of combinations of these samples from the different hole diameters were validated. Prediction errors, expressed as root mean square error of cross validation of the beef samples, were 0.73-1.50% for fat, 0.75-1.33% for moisture and 0.23-0.32% for protein, depending on the hole diameter of the grinder plate. Calibrations from samples ground with the smallest hole diameters gave lowest prediction errors. The present prediction error results are only slightly higher compared to reported prediction error results using conventional at- and off-line NIR instruments. It is concluded that the on-line NIR prediction results were acceptable for samples ground with grinder plates of 4, 8 or 13 mm hole diameter.

  8. A measure for provisional-and-urgent sanitary improvement in developing countries: septic-tank performance improvement.

    Science.gov (United States)

    Harada, H; Dong, N T; Matsui, S

    2008-01-01

    Although many cities have planed to develop sewerages in developing countries, sewerage establishment still requires huge investment and engineering efforts. Improvement of existing sanitation facilities may contribute the betterment of urban sanitation before sewerage establishment. The purpose of this study is to propose a measure to improve urban sanitation in areas where a sewerage development plan is proposed but has not been yet established, based on a case study in Hanoi, Vietnam. We found that 90.5% of human excreta flowed into septic tanks. However, 89.6% of septic tanks have never been desludged in the past and their performance was observed to be at a low level. The study also showed that if they introduce regular desludging with a frequency of once a year, they can eliminate 72.8% of COD loads from septic tanks. It was indicated that the performance can be dramatically recovered by regular desludging, which could contribute urban sanitation improvement in Hanoi. In conclusion, the performance recovery of septic tanks by regular desludging was proposed as a provisional-and-urgent measure for urban sanitation improvement, together with the septage treatment in sewage sludge treatment facilities, which should be established earlier than other facilities of sewage treatment systems. IWA Publishing 2008.

  9. Comparison of distance sampling estimates to a known population ...

    African Journals Online (AJOL)

    Line-transect sampling was used to obtain abundance estimates of an Ant-eating Chat Myrmecocichla formicivora population to compare these with the true size of the population. The population size was determined by a long-term banding study, and abundance estimates were obtained by surveying line transects.

  10. Microfluidic electrochemical sensor for on-line monitoring of aerosol oxidative activity.

    Science.gov (United States)

    Sameenoi, Yupaporn; Koehler, Kirsten; Shapiro, Jeff; Boonsong, Kanokporn; Sun, Yele; Collett, Jeffrey; Volckens, John; Henry, Charles S

    2012-06-27

    Particulate matter (PM) air pollution has a significant impact on human morbidity and mortality; however, the mechanisms of PM-induced toxicity are poorly defined. A leading hypothesis states that airborne PM induces harm by generating reactive oxygen species in and around human tissues, leading to oxidative stress. We report here a system employing a microfluidic electrochemical sensor coupled directly to a particle-into-liquid sampler (PILS) system to measure aerosol oxidative activity in an on-line format. The oxidative activity measurement is based on the dithiothreitol (DTT) assay, where, after being oxidized by PM, the remaining reduced DTT is analyzed by the microfluidic sensor. The sensor consists of an array of working, reference, and auxiliary electrodes fabricated in a poly(dimethylsiloxane)-based microfluidic device. Cobalt(II) phthalocyanine-modified carbon paste was used as the working electrode material, allowing selective detection of reduced DTT. The electrochemical sensor was validated off-line against the traditional DTT assay using filter samples taken from urban environments and biomass burning events. After off-line characterization, the sensor was coupled to a PILS to enable on-line sampling/analysis of aerosol oxidative activity. Urban dust and industrial incinerator ash samples were aerosolized in an aerosol chamber and analyzed for their oxidative activity. The on-line sensor reported DTT consumption rates (oxidative activity) in good correlation with aerosol concentration (R(2) from 0.86 to 0.97) with a time resolution of approximately 3 min.

  11. Generation of induced pluripotent stem cell line (ZZUi011-A from urine sample of a normal human

    Directory of Open Access Journals (Sweden)

    Huifang Sun

    2018-05-01

    Full Text Available Urine cells collected from 200 mL clean midsection urine of a 25-year-old healthy man were reprogrammed into pluripotent stem cells via Sendai virus delivery system. The induced pluripotent stem cells showed a normal karyotype and exhibited the potential to differentiate into three germ layers in a teratoma assay. This cell line may serve as a useful control for comparison with other pluripotent stem cell lines induced from somatic cells of patients with genetic neurodegenerative disorders.

  12. A simple and highly sensitive on-line column extraction liquid chromatography-tandem mass spectrometry method for the determination of protein-unbound tacrolimus in human plasma samples.

    Science.gov (United States)

    Bittersohl, Heike; Schniedewind, Björn; Christians, Uwe; Luppa, Peter B

    2018-04-27

    Therapeutic drug monitoring (TDM) of the immunosuppressive drug tacrolimus is essential to avoid side effects and rejection of the allograft after transplantation. In the blood circulation, tacrolimus is largely located inside erythrocytes or bound to plasma proteins and less than 0.1% is protein-unbound (free). One basic principle of clinical pharmacology is that only free drug is pharmacologically active and monitoring this portion has the potential to better reflect the drug effect than conventional measurements of total tacrolimus in whole blood. To address this, a highly sensitive and straightforward on-line liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed, validated and applied to patient plasma samples. The sample preparation included ultracentrifugation and addition of the stable isotope labeled drug analogue D2,13C-tacrolimus, followed by on-line sample extraction and measurement using a Sciex QTRAP ® 6500 in the multiple reaction monitoring mode. Due to very low concentrations of protein-unbound tacrolimus, it was important to develop a highly sensitive, precise and accurate assay. Here, we first report the efficient formation of tacrolimus lithium adduct ions, which greatly increased assay sensitivity. A lower limit of quantification (LLOQ) of 1 pg/mL (10 fg on column) was achieved and the assay was linear between 1 and 200 pg/mL. There was no carry-over detected. The inaccuracy ranged from -9.8 to 7.4% and the greatest imprecision was 7.5%. The matrix factor was found to be smaller than 1.1%. In summary, this method represents a suitable tool to investigate the potential clinical value of free tacrolimus monitoring in organ transplant recipients. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. THE BOSS EMISSION-LINE LENS SURVEY (BELLS). I. A LARGE SPECTROSCOPICALLY SELECTED SAMPLE OF LENS GALAXIES AT REDSHIFT {approx}0.5

    Energy Technology Data Exchange (ETDEWEB)

    Brownstein, Joel R.; Bolton, Adam S.; Pandey, Parul [Department of Physics and Astronomy, University of Utah, Salt Lake City, UT 84112 (United States); Schlegel, David J. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Eisenstein, Daniel J. [Harvard College Observatory, 60 Garden Street, MS 20, Cambridge, MA 02138 (United States); Kochanek, Christopher S. [Department of Astronomy and Center for Cosmology and Astroparticle Physics, Ohio State University, Columbus, OH 43210 (United States); Connolly, Natalia [Department of Physics, Hamilton College, Clinton, NY 13323 (United States); Maraston, Claudia [Institute of Cosmology and Gravitation, University of Portsmouth, Portsmouth PO1 3FX (United Kingdom); Seitz, Stella [University Observatory Munich, Scheinstrasse 1, 81679 Muenchen (Germany); Wake, David A. [Department of Astronomy, Yale University, New Haven, CT 06520 (United States); Wood-Vasey, W. Michael [Pittsburgh Center for Particle Physics, Astrophysics, and Cosmology (PITT-PACC), Department of Physics and Astronomy, University of Pittsburgh, Pittsburgh, PA 15260 (United States); Brinkmann, Jon [Apache Point Observatory, P.O. Box 59, Sunspot, NM 88349 (United States); Schneider, Donald P. [Department of Astronomy and Astrophysics and Institute for Gravitation and the Cosmos, Pennsylvania State University, University Park, PA 16802 (United States); Weaver, Benjamin A. [Center for Cosmology and Particle Physics, New York University, New York, NY 10003 (United States)

    2012-01-01

    We present a catalog of 25 definite and 11 probable strong galaxy-galaxy gravitational lens systems with lens redshifts 0.4 {approx}< z {approx}< 0.7, discovered spectroscopically by the presence of higher-redshift emission lines within the Baryon Oscillation Spectroscopic Survey (BOSS) of luminous galaxies, and confirmed with high-resolution Hubble Space Telescope (HST) images of 44 candidates. Our survey extends the methodology of the Sloan Lens Advanced Camera for Surveys survey (SLACS) to higher redshift. We describe the details of the BOSS spectroscopic candidate detections, our HST ACS image processing and analysis methods, and our strong gravitational lens modeling procedure. We report BOSS spectroscopic parameters and ACS photometric parameters for all candidates, and mass-distribution parameters for the best-fit singular isothermal ellipsoid models of definite lenses. Our sample to date was selected using only the first six months of BOSS survey-quality spectroscopic data. The full five-year BOSS database should produce a sample of several hundred strong galaxy-galaxy lenses and in combination with SLACS lenses at lower redshift, strongly constrain the redshift evolution of the structure of elliptical, bulge-dominated galaxies as a function of luminosity, stellar mass, and rest-frame color, thereby providing a powerful test for competing theories of galaxy formation and evolution.

  14. Protocol for Microplastics Sampling on the Sea Surface and Sample Analysis

    Science.gov (United States)

    Kovač Viršek, Manca; Palatinus, Andreja; Koren, Špela; Peterlin, Monika; Horvat, Petra; Kržan, Andrej

    2016-01-01

    Microplastic pollution in the marine environment is a scientific topic that has received increasing attention over the last decade. The majority of scientific publications address microplastic pollution of the sea surface. The protocol below describes the methodology for sampling, sample preparation, separation and chemical identification of microplastic particles. A manta net fixed on an »A frame« attached to the side of the vessel was used for sampling. Microplastic particles caught in the cod end of the net were separated from samples by visual identification and use of stereomicroscopes. Particles were analyzed for their size using an image analysis program and for their chemical structure using ATR-FTIR and micro FTIR spectroscopy. The described protocol is in line with recommendations for microplastics monitoring published by the Marine Strategy Framework Directive (MSFD) Technical Subgroup on Marine Litter. This written protocol with video guide will support the work of researchers that deal with microplastics monitoring all over the world. PMID:28060297

  15. SCADA based radioactive sample bottle delivery system for fuel reprocessing project

    International Nuclear Information System (INIS)

    Kaushik, Subrat; Munj, Niket; Chauhan, R.K.; Kumar, Pramod; Mishra, A.C.

    2011-01-01

    Radioactive samples of process streams need to be analyzed in centralized control lab for measuring concentration of heavy elements as well as activity at various stages of re-processing plants. The sample is taken from biologically shielded process cells remotely through sampling blisters in sample bottles. These are then transferred to control lab located about 50 meters using vacuum transfer system. The bottle movement is tracked from origin to destination in rich HMI SCADA system using Infra-red non contact type proximity sensors located along sampling line and these sensors are connected to PLC in a fail-safe mode. The sample bottle travels at a speed of 10 m/s under vacuum motive force and the detection time is of the order of 1 mS. The contact time Flow meters have been used to know the air flow in sampling line

  16. High rate spectroscopy for on-line nuclear coal analyzer (Nucoalyzer)

    International Nuclear Information System (INIS)

    McQuaid, J.H.; Brown, D.R.; Gozani, T.; Bozorgmanesh, H.

    1980-01-01

    A high count rate, time-variant Ge(Li) spectrometer has been developed for on-line coal analysis. The analyzer is being fabricated for use in a power generating station. Prompt neutron activation of coal samples is the basis of analysis, with 252 Cf as the source for irradiation. The spectroscopy system allows counting rates up to 150 k counts per second without significant loss in energy resolution or peak shape. The high data throughput allows the coal analyzer to be used for on-line process control. The coal analyzer will be discussed, with emphasis on the high-rate signal processing system. Results of analysis of coal samples will be presented

  17. Pilot experimental study on continual spectrum thermal neutron in-line phase contrast radiography

    International Nuclear Information System (INIS)

    Tang Bin; Huo Heyong; Wu Yang

    2009-01-01

    The in-line phase contrast radiography is one of phase contrast imaging methods. The neutron in-line phase contrast is developed with X-rays phase contrast radiography. In the paper, the principle of in-line phase contrast is introduced briefly and the experimental result of thermal neutron in-line contrast at SPRR-300 is analysed. It shows that thermal neutron can be used as in-line phase contrast radiography and enhances the edge of some sample in radiography and complements the disadvantage of conventional neutron radiography. (authors)

  18. Determination of anions with an on-line capillary electrophoresis method; Anionien on-line maeaeritys kapillaarielektroforeesilla - MPKT 10

    Energy Technology Data Exchange (ETDEWEB)

    Siren, H.; Saerme, T.; Kotiaho, T.; Hiissa, T.; Savolahti, P.; Komppa, V. [VTT Chemical Technology, Espoo (Finland)

    1998-12-31

    The aim of the study was to set-up an on-line capillary electrophoresis method for determination of anions in process waters of pulp and paper industry with exporting the results to the process control system of the mill. The quantification is important, since it will give information about the possible causes of precipitation. In recent years, the capillary electrophoresis (CE) due to its high separation efficiency has been shown as a method to take into consideration when analyzing chemical species ranging from small inorganic anions to different macromolecules. Many compounds are not easily detected in their native state, why analysis methods must be developed to improve their detection. Especially, small inorganic and organic anions which do not have chromophores are not sensitive enough for direct-UV detection. In such analyses the anions are mostly detected with indirect-UV technique. Capillary electrophoresis instruments are used to analyze samples in off-line, which seldom represent the situation in process. Therefore, on-line instrument technology with autoanalyzing settings will be needed in quality control. The development of a fully automatic capillary electrophoresis system is underway in co-operation with KCL (The Finnish Pulp and Paper Research Institute). In our research, we have first concentrated on the determination of sulphate in waters of paper industry. The method used for detection of sulphate is based on indirect-UV detection with CE, where the background electrolyte (BGE) is an absorbing mixture of secondary amines. The whole procedure for quantification of sulphate is performed within 15 minutes, after which a new sample is analyzed automatically. The only sample pretreatment is filtration, which is necessary before analysis. The concentrations of sulphate in process waters tested were between 300 and 800 ppm. Our tests show that a simultaneous determination of chloride, sulphate, nitrate, nitrite, sulphite, carbonate and oxalate is also

  19. Determination of anions with an on-line capillary electrophoresis method; Anionien on-line maeaeritys kapillaarielektroforeesilla - MPKT 10

    Energy Technology Data Exchange (ETDEWEB)

    Siren, H; Saerme, T; Kotiaho, T; Hiissa, T; Savolahti, P; Komppa, V [VTT Chemical Technology, Espoo (Finland)

    1999-12-31

    The aim of the study was to set-up an on-line capillary electrophoresis method for determination of anions in process waters of pulp and paper industry with exporting the results to the process control system of the mill. The quantification is important, since it will give information about the possible causes of precipitation. In recent years, the capillary electrophoresis (CE) due to its high separation efficiency has been shown as a method to take into consideration when analyzing chemical species ranging from small inorganic anions to different macromolecules. Many compounds are not easily detected in their native state, why analysis methods must be developed to improve their detection. Especially, small inorganic and organic anions which do not have chromophores are not sensitive enough for direct-UV detection. In such analyses the anions are mostly detected with indirect-UV technique. Capillary electrophoresis instruments are used to analyze samples in off-line, which seldom represent the situation in process. Therefore, on-line instrument technology with autoanalyzing settings will be needed in quality control. The development of a fully automatic capillary electrophoresis system is underway in co-operation with KCL (The Finnish Pulp and Paper Research Institute). In our research, we have first concentrated on the determination of sulphate in waters of paper industry. The method used for detection of sulphate is based on indirect-UV detection with CE, where the background electrolyte (BGE) is an absorbing mixture of secondary amines. The whole procedure for quantification of sulphate is performed within 15 minutes, after which a new sample is analyzed automatically. The only sample pretreatment is filtration, which is necessary before analysis. The concentrations of sulphate in process waters tested were between 300 and 800 ppm. Our tests show that a simultaneous determination of chloride, sulphate, nitrate, nitrite, sulphite, carbonate and oxalate is also

  20. A fully blanketed early B star LTE model atmosphere using an opacity sampling technique

    International Nuclear Information System (INIS)

    Phillips, A.P.; Wright, S.L.

    1980-01-01

    A fully blanketed LTE model of a stellar atmosphere with Tsub(e) = 21914 K (thetasub(e) = 0.23), log g = 4 is presented. The model includes an explicit representation of the opacity due to the strongest lines, and uses a statistical opacity sampling technique to represent the weaker line opacity. The sampling technique is subjected to several tests and the model is compared with an atmosphere calculated using the line-distribution function method. The limitations of the distribution function method and the particular opacity sampling method used here are discussed in the light of the results obtained. (author)

  1. On-line and bulk analysis for the resource industries

    International Nuclear Information System (INIS)

    Lim, C.S.; Sowerby, B.D.; Tickner, J.R.; Madsen, I.C.

    2001-01-01

    Nuclear techniques are the basis of many CSIRO on-line and bulk analysis systems that are now widely used in the mineral and energy industries. The continuous analysis and rapid response of these systems have led to improved control of mining, processing and blending operations. This paper reviews recent developments in neutron, gamma-ray and X-ray techniques for on-line and bulk analysis by CSIRO Minerals including neutron techniques for the on-conveyor belt determination of the composition of cement raw meal, the on-line analysis of composition in pyrometallurgical applications, the on-conveyor belt determination of ash in coal, and the rapid and accurate determination of gold in bulk laboratory samples. The paper also discusses a new gamma-ray technique for the on-line determination of ash in coal and the application of X-ray diffraction techniques for the on-line determination of mineralogy in the cement industry

  2. Quasar outflow energetics from broad absorption line variability

    Science.gov (United States)

    McGraw, S. M.; Shields, J. C.; Hamann, F. W.; Capellupo, D. M.; Herbst, H.

    2018-03-01

    Quasar outflows have long been recognized as potential contributors to the co-evolution between supermassive black holes (SMBHs) and their host galaxies. The role of outflows in active galactic nucleus (AGN) feedback processes can be better understood by placing observational constraints on wind locations and kinetic energies. We utilize broad absorption line (BAL) variability to investigate the properties of a sample of 71 BAL quasars with P V broad absorption. The presence of P V BALs indicates that other BALs like C IV are saturated, such that variability in those lines favours clouds crossing the line of sight. We use these constraints with measurements of BAL variability to estimate outflow locations and energetics. Our data set consists of multiple-epoch spectra from the Sloan Digital Sky Survey and MDM Observatory. We detect significant (4σ) BAL variations from 10 quasars in our sample over rest-frame time-scales between ≤0.2-3.8 yr. Our derived distances for the 10 variable outflows are nominally ≲ 1-10 pc from the SMBH using the transverse-motion scenario, and ≲ 100-1000 pc from the central source using ionization-change considerations. These distances, in combination with the estimated high outflow column densities (i.e. NH ≳ 1022 cm-2), yield outflow kinetic luminosities between ˜ 0.001 and 1 times the bolometric luminosity of the quasar, indicating that many absorber energies within our sample are viable for AGN feedback.

  3. Occurrence of male-specific bacteriophage in feral and domestic animal wastes, human feces, and human-associated wastewaters.

    Science.gov (United States)

    Calci, K R; Burkhardt, W; Watkins, W D; Rippey, S R

    1998-12-01

    Male-specific bacteriophage (MSB) densities were determined in animal and human fecal wastes to assess their potential impact on aquatic environments. Fecal samples (1,031) from cattle, chickens, dairy cows, dogs, ducks, geese, goats, hogs, horses, seagulls, sheep, and humans as well as 64 sewerage samples were examined for MSB. All animal species were found to harbor MSB, although the great majority excreted these viruses at very low levels. The results from this study demonstrate that in areas affected by both human and animal wastes, wastewater treatment plants are the principal contributors of MSB to fresh, estuarine, and marine waters.

  4. Investigation of mutagenicity of extracts of hydrobionts from lake Drukshiai and water from its streamlets

    International Nuclear Information System (INIS)

    Lekevichius, R.; Dagyte, B.; Sabaliuniene, I.; Shumyliene, I.; Mishkelevichiute, E.

    1995-01-01

    Rain-water samples from Ignalina NPP buildings and industry sewerage water samples collected in 1993-1994 induced statistically significant increase in levels of frameshift and and base-substitution mutations in Salmonella typhimurium Ames tester strains. It was found that mutagens originated not by Ignalina NPP get into lake Drukshiai from its streamlets. Extracts from 4 species of molluscs did not induce frameshift and base-substitution mutations in Ames tester-strains. Among extracts of liver, muscles and gonads from 4 fish species tested, the highest mutagenicity levels were induced by extracts of gonads from the largest fish. (author). 4 refs., 4 tabs

  5. Flow cytometric analysis of microbial contamination in food industry technological lines--initial study.

    Science.gov (United States)

    Józwa, Wojciech; Czaczyk, Katarzyna

    2012-04-02

    Flow cytometry constitutes an alternative for traditional methods of microorganisms identification and analysis, including methods requiring cultivation step. It enables the detection of pathogens and other microorganisms contaminants without the need to culture microbial cells meaning that the sample (water, waste or food e.g. milk, wine, beer) may be analysed directly. This leads to a significant reduction of time required for analysis allowing monitoring of production processes and immediate reaction in case of contamination or any disruption occurs. Apart from the analysis of raw materials or products on different stages of manufacturing process, the flow cytometry seems to constitute an ideal tool for the assessment of microbial contamination on the surface of technological lines. In the present work samples comprising smears from 3 different surfaces of technological lines from fruit and vegetable processing company from Greater Poland were analysed directly with flow cytometer. The measured parameters were forward and side scatter of laser light signals allowing the estimation of microbial cell contents in each sample. Flow cytometric analysis of the surface of food industry production lines enable the preliminary evaluation of microbial contamination within few minutes from the moment of sample arrival without the need of sample pretreatment. The presented method of fl ow cytometric initial evaluation of microbial state of food industry technological lines demonstrated its potential for developing a robust, routine method for the rapid and labor-saving detection of microbial contamination in food industry.

  6. Antiproliferative effects of the readily extractable fractions prepared from various citrus juices on several cancer cell lines.

    Science.gov (United States)

    Kawaii, S; Tomono, Y; Katase, E; Ogawa, K; Yano, M

    1999-07-01

    To eliminate the masking effect by flavonoid glycosides, which comprise approximately 70% of conventionally prepared sample, the readily extractable fraction from Citrus juice, which was prepared by adsorbing on HP-20 resin and eluting with ethanol and acetone from the resin, was subjected to antiproliferative tests against several cancer cell lines. Screening of 34 Citrus juices indicated that King (Citrus nobilis) strongly inhibited proliferation of all cancer cell lines examined. Sweet lime and Kabuchi inhibited three of the four cancer cell lines. In contrast, these samples were substantially less cytotoxic toward normal human cell lines.

  7. A high-efficiency neutron coincidence counter for small samples

    International Nuclear Information System (INIS)

    Miller, M.C.; Menlove, H.O.; Russo, P.A.

    1991-01-01

    The inventory sample coincidence counter (INVS) has been modified to enhance its performance. The new design is suitable for use with a glove box sample-well (in-line application) as well as for use in the standard at-line mode. The counter has been redesigned to count more efficiently and be less sensitive to variations in sample position. These factors lead to a higher degree of precision and accuracy in a given counting period and allow for the practical use of the INVS counter with gamma-ray isotopics to obtain a plutonium assay independent of operator declarations and time-consuming chemicals analysis. A calculation study was performed using the Los Alamos transport code MCNP to optimize the design parameters. 5 refs., 7 figs., 8 tabs

  8. HIGH-REDSHIFT SDSS QUASARS WITH WEAK EMISSION LINES

    International Nuclear Information System (INIS)

    Diamond-Stanic, Aleksandar M.; Fan Xiaohui; Jiang Linhua; Kim, J. Serena; Schmidt, Gary D.; Smith, Paul S.; Vestergaard, Marianne; Young, Jason E.; Brandt, W. N.; Shemmer, Ohad; Gibson, Robert R.; Schneider, Donald P.; Strauss, Michael A.; Shen Yue; Anderson, Scott F.; Carilli, Christopher L.; Richards, Gordon T.

    2009-01-01

    We identify a sample of 74 high-redshift quasars (z > 3) with weak emission lines from the Fifth Data Release of the Sloan Digital Sky Survey and present infrared, optical, and radio observations of a subsample of four objects at z > 4. These weak emission-line quasars (WLQs) constitute a prominent tail of the Lyα + N v equivalent width distribution, and we compare them to quasars with more typical emission-line properties and to low-redshift active galactic nuclei with weak/absent emission lines, namely BL Lac objects. We find that WLQs exhibit hot (T ∼ 1000 K) thermal dust emission and have rest-frame 0.1-5 μm spectral energy distributions that are quite similar to those of normal quasars. The variability, polarization, and radio properties of WLQs are also different from those of BL Lacs, making continuum boosting by a relativistic jet an unlikely physical interpretation. The most probable scenario for WLQs involves broad-line region properties that are physically distinct from those of normal quasars.

  9. Estimating the encounter rate variance in distance sampling

    Science.gov (United States)

    Fewster, R.M.; Buckland, S.T.; Burnham, K.P.; Borchers, D.L.; Jupp, P.E.; Laake, J.L.; Thomas, L.

    2009-01-01

    The dominant source of variance in line transect sampling is usually the encounter rate variance. Systematic survey designs are often used to reduce the true variability among different realizations of the design, but estimating the variance is difficult and estimators typically approximate the variance by treating the design as a simple random sample of lines. We explore the properties of different encounter rate variance estimators under random and systematic designs. We show that a design-based variance estimator improves upon the model-based estimator of Buckland et al. (2001, Introduction to Distance Sampling. Oxford: Oxford University Press, p. 79) when transects are positioned at random. However, if populations exhibit strong spatial trends, both estimators can have substantial positive bias under systematic designs. We show that poststratification is effective in reducing this bias. ?? 2008, The International Biometric Society.

  10. Evaluation of inlet sampling integrity on NSF/NCAR airborne platforms

    Science.gov (United States)

    Campos, T. L.; Stith, J. L.; Stephens, B. B.; Romashkin, P.

    2017-12-01

    An inlet test project was conducted during IDEAS-IV-GV (2013), to evaluate the sampling integrity of two inlet designs. Use of a single CO2 sensor provided a high precision detector and a large difference in the mean cabin and external concentrations (500-700 ppmv in the cabin). The original HIAPER Modular InLet (HIMIL) is comprised of a tapered flow straightening flow through `cigar' mounted to a strut. The cigar center sampling line sits 12" from the fuselage skin. An o-ring seals the feedthrough plate coupling sampling lines from the strut into the cigar. However, there is no seal to prevent air inside the strut from seeping out around the cigar body. A pressure-equalizing drain hole in the strut access panel; it was positioned at an approximate distance of 4" from the fuselage to ensure that air from any source that drained out of the strut was confined to a low release point. A second aft-facing inlet design was also evaluated. The sampling center line was moved farther from the fuselage at a height of 16". A similar approach was also applied to sampling locations on the C-130 in 2015. The results of these tests and recommendations for best practices will be presented.

  11. Log sampling methods and software for stand and landscape analyses.

    Science.gov (United States)

    Lisa J. Bate; Torolf R. Torgersen; Michael J. Wisdom; Edward O. Garton; Shawn C. Clabough

    2008-01-01

    We describe methods for efficient, accurate sampling of logs at landscape and stand scales to estimate density, total length, cover, volume, and weight. Our methods focus on optimizing the sampling effort by choosing an appropriate sampling method and transect length for specific forest conditions and objectives. Sampling methods include the line-intersect method and...

  12. 40 CFR 1065.145 - Gaseous and PM probes, transfer lines, and sampling system components.

    Science.gov (United States)

    2010-07-01

    ... Scrubber. You may use ammonia scrubbers for any or all gaseous sampling systems to prevent interference.... Follow the ammonia scrubber manufacturer's recommendations or use good engineering judgment in applying ammonia scrubbers. (f) Optional sample-conditioning components for PM sampling. You may use the following...

  13. On-line moisture analysis

    CERN Document Server

    Cutmore, N G

    2002-01-01

    Measurement of the moisture content of iron ore has become a key issue for controlling moisture additions for dust suppression. In most cases moisture content is still determined by manual or automatic sampling of the ore stream, followed by conventional laboratory analysis by oven drying. Although this procedure enables the moisture content to be routinely monitored, it is too slow for control purposes. This has generated renewed interest in on-line techniques for the accurate and rapid measurement of moisture in iron ore on conveyors. Microwave transmission techniques have emerged over the past 40 years as the dominant technology for on-line measurement of moisture in bulk materials, including iron ores. Alternative technologies have their limitations. Infra-red analysers are used in a variety of process industries, but rely on the measurement of absorption by moisture in a very thin surface layer. Consequently such probes may be compromised by particle size effects and biased presentation of the bulk mater...

  14. Line facilities outline

    International Nuclear Information System (INIS)

    1998-08-01

    This book deals with line facilities. The contents of this book are outline line of wire telecommunication ; development of line, classification of section of line and theory of transmission of line, cable line ; structure of line, line of cable in town, line out of town, domestic cable and other lines, Optical communication ; line of optical cable, transmission method, measurement of optical communication and cable of the sea bottom, Equipment of telecommunication line ; telecommunication line facilities and telecommunication of public works, construction of cable line and maintenance and Regulation of line equipment ; regulation on technique, construction and maintenance.

  15. On Line Characterization of SiC Nanoparticles Produced by Laser Pyrolysis

    International Nuclear Information System (INIS)

    Wattieaux, G; Lecerf, P; Meyer, L; Boufendi, L; Leconte, Y; Sublemontier, O; Herlin, N; Asimakopoulou, A; Tsakis, A; Daskalos, M; Konstandopoulos, A G; Ouf, F X

    2011-01-01

    On Line Measurements campaigns have been carried out for the first time in IRAMIS/SPAM CEA's laser gas-phase pyrolysis nanoparticles production facilities. The produced aerosol is composed of Argon and/or Helium laden with SiC nanoparticles concentrated up to ∼14 mg/l. Different commercial apparatus were used for sampling, and characterisation of size, and morphology of the particles. A series of experiment is performed by IRSN with a DMS500 from Cambustion Ltd TM , which gives electrical mobility equivalent diameter distribution in real time. Particles are sampled with an ejector-diluter VKL-10 from Palas TM . On the same sampling line, APTL performed aerodynamic equivalent diameter mass distribution using a Nanomoudi from MSP Corp. TM and TEM post analysis, as well as post elemental analysis (EDS) after collection on TEM grid with a Thermophoretic Precipitator (TP). A previously developed model is used to obtain the aggregate morphology and primary particles sizes. In addition to these commercial or well-known techniques, a new patent-pending technique called RFPM (Radio Frequency Plasma Metrology developed by CILAS + GREMI in the frame of NANOCARA program) is tested for the first time off the lab. The principle is based on levitation of particles in plasma RF. The entire set up is a prototype, including the sampling line. Experiments showed that this technique is very promising for on line gas phase monitoring, even though future improvements are needed, especially on the direct injection of the sample in the measuring chamber. First results of size distribution on pyrolysis line were obtained: three modes of different geometric mean diameter D50 were measured. Further analysis of TEM micrographs gave insight on these three modes, they can be interpreted as primary particles, aggregated particles, and a third one which could be composed of silica oxide nanoparticles issued from the combustion of the remaining silane initiated by an air leak in the exhaust of

  16. Zinc estimates in ore and slag samples and analysis of ash in coal samples

    International Nuclear Information System (INIS)

    Umamaheswara Rao, K.; Narayana, D.G.S.; Subrahmanyam, Y.

    1984-01-01

    Zinc estimates in ore and slag samples were made using the radioisotope X-ray fluorescence method. A 10 mCi 238 Pu was employed as the primary source of radiation and a thin crystal NaI(Ti) spectrometer was used to accomplish the detection of the 8.64 keV Zinc K-characteristic X-ray line. The results are reported. Ash content of coal concerning about 100 samples from Ravindra Khani VI and VII mines in Andhra Pradesh were measured using X-ray backscattering method with compensation for varying concentrations of iron in different coal samples through iron-X-ray fluorescent intensity measurements. The ash percent is found to range from 10 to 40. (author)

  17. Electronic Current Transducer (ECT) for high voltage dc lines

    Science.gov (United States)

    Houston, J. M.; Peters, P. H., Jr.; Summerayes, H. R., Jr.; Carlson, G. J.; Itani, A. M.

    1980-02-01

    The development of a bipolar electronic current transducer (ECT) for measuring the current in a high voltage dc (HVDC) power line at line potential is discussed. The design and construction of a free standing ECT for use on a 400 kV line having a nominal line current of 2000 A is described. Line current is measured by a 0.0001 ohm shunt whose voltage output is sampled by a 14 bit digital data link. The high voltage interface between line and ground is traversed by optical fibers which carry digital light signals as far as 300 m to a control room where the digital signal is converted back to an analog representation of the shunt voltage. Two redundant electronic and optical data links are used in the prototype. Power to operate digital and optical electronics and temperature controlling heaters at the line is supplied by a resistively and capacitively graded 10 stage cascade of ferrite core transformers located inside the hollow, SF6 filled, porcelain support insulator. The cascade is driven by a silicon controlled rectifier inverter which supplies about 100 W of power at 30 kHz.

  18. Accelerated solvent extraction followed by on-line solid-phase extraction coupled to ion trap LC/MS/MS for analysis of benzalkonium chlorides in sediment samples

    Science.gov (United States)

    Ferrer, I.; Furlong, E.T.

    2002-01-01

    Benzalkonium chlorides (BACs) were successfully extracted from sediment samples using a new methodology based on accelerated solvent extraction (ASE) followed by an on-line cleanup step. The BACs were detected by liquid chromatography/ion trap mass spectrometry (LC/MS) or tandem mass spectrometry (MS/MS) using an electrospray interface operated in the positive ion mode. This methodology combines the high efficiency of extraction provided by a pressurized fluid and the high sensitivity offered by the ion trap MS/MS. The effects of solvent type and ASE operational variables, such as temperature and pressure, were evaluated. After optimization, a mixture of acetonitrile/water (6:4 or 7:3) was found to be most efficient for extracting BACs from the sediment samples. Extraction recoveries ranged from 95 to 105% for C12 and C14 homologues, respectively. Total method recoveries from fortified sediment samples, using a cleanup step followed by ASE, were 85% for C12BAC and 79% for C14-BAC. The methodology developed in this work provides detection limits in the subnanogram per gram range. Concentrations of BAC homologues ranged from 22 to 206 ??g/kg in sediment samples from different river sites downstream from wastewater treatment plants. The high affinity of BACs for soil suggests that BACs preferentially concentrate in sediment rather than in water.

  19. Looking into individual coffee beans during the roasting process: direct micro-probe sampling on-line photo-ionisation mass spectrometric analysis of coffee roasting gases.

    Science.gov (United States)

    Hertz-Schünemann, Romy; Streibel, Thorsten; Ehlert, Sven; Zimmermann, Ralf

    2013-09-01

    A micro-probe (μ-probe) gas sampling device for on-line analysis of gases evolving in confined, small objects by single-photon ionisation time-of-flight mass spectrometry (SPI-TOFMS) was developed. The technique is applied for the first time in a feasibility study to record the formation of volatile and flavour compounds during the roasting process within (inside) or in the direct vicinity (outside) of individual coffee beans. A real-time on-line analysis of evolving volatile and semi-volatile organic compounds (VOC and SVOC) as they are formed under the mild pyrolytic conditions of the roasting process was performed. The soft-ionisation mass spectra depict a molecular ion signature, which is well corresponding with the existing knowledge of coffee roasting and evolving compounds. Additionally, thereby it is possible to discriminate between Coffea arabica (Arabica) and Coffea canephora (Robusta). The recognized differences in the roasting gas profiles reflect the differences in the precursor composition of the coffee cultivars very well. Furthermore, a well-known set of marker compounds for Arabica and Robusta, namely the lipids kahweol and cafestol (detected in their dehydrated form at m/z 296 and m/z 298, respectively) were observed. If the variation in time of different compounds is observed, distinctly different evolution behaviours were detected. Here, phenol (m/z 94) and caffeine (m/z 194) are exemplary chosen, whereas phenol shows very sharp emission peaks, caffeine do not have this highly transient behaviour. Finally, the changes of the chemical signature as a function of the roasting time, the influence of sampling position (inside, outside) and cultivar (Arabica, Robusta) is investigated by multivariate statistics (PCA). In summary, this pilot study demonstrates the high potential of the measurement technique to enhance the fundamental knowledge of the formation processes of volatile and semi-volatile flavour compounds inside the individual coffee bean.

  20. The Lyman alpha reference sample

    DEFF Research Database (Denmark)

    Hayes, M.; Östlin, G.; Schaerer, D.

    2013-01-01

    We report on new imaging observations of the Lyman alpha emission line (Lyα), performed with the Hubble Space Telescope, that comprise the backbone of the Lyman alpha Reference Sample. We present images of 14 starburst galaxies at redshifts 0.028

  1. Comparison of vapor sampling system (VSS) and in situ vapor sampling (ISVS) methods on Tanks C-107, BY-108, and S-102

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Edwards, J.A.; Evans, J.C.

    1996-05-01

    The objective of this report is to evaluate the equivalency of two methods used to sample nonradioactive gases and vapors in the Hanford Site high-level waste tank headspaces. In addition to the comparison of the two sampling methods, the effects of an in-line fine particle filter on sampling results are also examined to determine whether results are adversely affected by its presence. This report discusses data from a January 1996 sampling

  2. 7 CFR 42.143 - Operating Characteristic (OC) curves for on-line sampling and inspection.

    Science.gov (United States)

    2010-01-01

    ...=Number of sample units in a subgroup. T=Subgroup tolerance.L=Acceptance limit.S=Starting value. EC02SE91... ng=Number of sample units in a subgroup. T=Subgroup tolerance. L=Acceptance limit. S=Starting value... of sample units in a subgroup. T=Subgroup tolerance. L=Acceptance limit. S=Starting value. EC02SE91...

  3. Similarity law for Widom lines and coexistence lines.

    Science.gov (United States)

    Banuti, D T; Raju, M; Ihme, M

    2017-05-01

    The coexistence line of a fluid separates liquid and gaseous states at subcritical pressures, ending at the critical point. Only recently, it became clear that the supercritical state space can likewise be divided into regions with liquidlike and gaslike properties, separated by an extension to the coexistence line. This crossover line is commonly referred to as the Widom line, and is characterized by large changes in density or enthalpy, manifesting as maxima in the thermodynamic response functions. Thus, a reliable representation of the coexistence line and the Widom line is important for sub- and supercritical applications that depend on an accurate prediction of fluid properties. While it is known for subcritical pressures that nondimensionalization with the respective species critical pressures p_{cr} and temperatures T_{cr} only collapses coexistence line data for simple fluids, this approach is used for Widom lines of all fluids. However, we show here that the Widom line does not adhere to the corresponding states principle, but instead to the extended corresponding states principle. We resolve this problem in two steps. First, we propose a Widom line functional based on the Clapeyron equation and derive an analytical, species specific expression for the only parameter from the Soave-Redlich-Kwong equation of state. This parameter is a function of the acentric factor ω and compares well with experimental data. Second, we introduce the scaled reduced pressure p_{r}^{*} to replace the previously used reduced pressure p_{r}=p/p_{cr}. We show that p_{r}^{*} is a function of the acentric factor only and can thus be readily determined from fluid property tables. It collapses both subcritical coexistence line and supercritical Widom line data over a wide range of species with acentric factors ranging from -0.38 (helium) to 0.34 (water), including alkanes up to n-hexane. By using p_{r}^{*}, the extended corresponding states principle can be applied within

  4. Unattended reaction monitoring using an automated microfluidic sampler and on-line liquid chromatography.

    Science.gov (United States)

    Patel, Darshan C; Lyu, Yaqi Fara; Gandarilla, Jorge; Doherty, Steve

    2018-04-03

    In-process sampling and analysis is an important aspect of monitoring kinetic profiles and impurity formation or rejection, both in development and during commercial manufacturing. In pharmaceutical process development, the technology of choice for a substantial portion of this analysis is high-performance liquid chromatography (HPLC). Traditionally, the sample extraction and preparation for reaction characterization have been performed manually. This can be time consuming, laborious, and impractical for long processes. Depending on the complexity of the sample preparation, there can be variability introduced by different analysts, and in some cases, the integrity of the sample can be compromised during handling. While there are commercial instruments available for on-line monitoring with HPLC, they lack capabilities in many key areas. Some do not provide integration of the sampling and analysis, while others afford limited flexibility in sample preparation. The current offerings provide a limited number of unit operations available for sample processing and no option for workflow customizability. This work describes development of a microfluidic automated program (MAP) which fully automates the sample extraction, manipulation, and on-line LC analysis. The flexible system is controlled using an intuitive Microsoft Excel based user interface. The autonomous system is capable of unattended reaction monitoring that allows flexible unit operations and workflow customization to enable complex operations and on-line sample preparation. The automated system is shown to offer advantages over manual approaches in key areas while providing consistent and reproducible in-process data. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. On-line chemistry monitoring for the secondary side

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    Babcock and Wilcox (B and W) has developed a computerized water chemistry data acquisition and management system for nuclear plant secondary coolant systems. The Integrated Water Chemistry Monitoring System (IWCMS) provides on-line monitoring of conditions and rapid trend analysis of sampled data. So far it has been installed at GPU Three Mile Island unit 1 and at Toledo Edison Davis-Besse. The IWCMS meets the following utility needs for monitoring power plant chemistry: control of chemistry conditions to minimize corrosion and extend component/system life; continuous analysis of data from on-line detectors and grab samples; expediting of transient recovery actions with trend, alarm and evaluation capability; provision for rapid sharing of useful operational chemistry information; concentration of attention on evaluation instead of data manipulation. The system is composed of three functional parts: data acquisition hardware; PC-based computer system and customised system software. (author)

  6. Calibration samples for accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Hershberger, R.L.; Flynn, D.S.; Gabbard, F.

    1981-01-01

    Radioactive samples with precisely known numbers of atoms are useful as calibration sources for lifetime measurements using accelerator mass spectrometry. Such samples can be obtained in two ways: either by measuring the production rate as the sample is created or by measuring the decay rate after the sample has been obtained. The latter method requires that a large sample be produced and that the decay constant be accurately known. The former method is a useful and independent alternative, especially when the decay constant is not well known. The facilities at the University of Kentucky for precision measurements of total neutron production cross sections offer a source of such calibration samples. The possibilities, while quite extensive, would be limited to the proton rich side of the line of stability because of the use of (p,n) and (α,n) reactions for sample production

  7. SCADA based radioactive sample bottle delivery system for fuel reprocessing project

    International Nuclear Information System (INIS)

    Kaushik, Subrat; Munj, Niket; Chauhan, R.K.; Jayaram, M.N.; Haneef, K.K.M.

    2014-01-01

    Radioactive samples of process streams need to be analyzed in centralized control lab for measuring concentration of heavy elements as well as activity at various stages of re-processing plants. The sample is taken from biologically shielded process cells remotely through sampling blisters in sample bottles. These are then transferred to control lab located about 50 meters using vacuum transfer system. The bottle movement is tracked from origin to destination in rich HMI SCADA system using Infra-red non contact type proximity sensors located along sampling line and these sensors are connected to PLC in a fail-safe mode. The sample bottle travels at a speed of 10 m/s under vacuum motive force and the detection time is of the order of 1 mS. The flow meters have been used to know the air flow in sampling line. The system has been designed, developed, tested and commissioned and in use for four years. (author)

  8. Field results for line intersect distance sampling of coarse woody debris

    Science.gov (United States)

    David L. R. Affleck

    2009-01-01

    A growing recognition of the importance of downed woody materials in forest ecosystem processes and global carbon budgets has sharpened the need for efficient sampling strategies that target this resource. Often the aggregate volume, biomass, or carbon content of the downed wood is of primary interest, making recently developed probability proportional-to-volume...

  9. A new mathematical formulation of the line-by-line method in case of weak line overlapping

    Science.gov (United States)

    Ishov, Alexander G.; Krymova, Natalie V.

    1994-01-01

    A rigorous mathematical proof is presented for multiline representation on the equivalent width of a molecular band which consists in the general case of n overlapping spectral lines. The multiline representation includes a principal term and terms of minor significance. The principal term is the equivalent width of the molecular band consisting of the same n nonoverlapping spectral lines. The terms of minor significance take into consideration the overlapping of two, three and more spectral lines. They are small in case of the weak overlapping of spectral lines in the molecular band. The multiline representation can be easily generalized for optically inhomogeneous gas media and holds true for combinations of molecular bands. If the band lines overlap weakly the standard formulation of line-by-line method becomes too labor-consuming. In this case the multiline representation permits line-by-line calculations to be performed more effectively. Other useful properties of the multiline representation are pointed out.

  10. 76 FR 51367 - China Shipping Container Lines Co., Ltd.; COSCO Container Lines Company Limited; Evergreen Line A...

    Science.gov (United States)

    2011-08-18

    ... FEDERAL MARITIME COMMISSION [Docket No. 11-12] China Shipping Container Lines Co., Ltd.; COSCO Container Lines Company Limited; Evergreen Line A Joint Service Agreement; Hanjin Shipping Co., Ltd... Maritime Commission (Commission) by China Shipping Container Lines Co., Ltd.; COSCO Container Lines Company...

  11. Real Life Poverty in America: Where the American Public Would Set the Poverty Line.

    Science.gov (United States)

    O'Hare, William; And Others

    This report discusses the results of a 1989 poll conducted by the Gallup Organization in which a representative sample of Americans were asked where they would set the poverty line. The poverty line in current use by the Federal Government was created in the mid-1960s, using data from the 1950s. Setting the poverty line involves a basic decision…

  12. On-line measurement and control in sustainable mineral processing and energy production

    International Nuclear Information System (INIS)

    Sowerby, B.D.

    2002-01-01

    Sustainable development can be defined as development that 'meets the needs of the present without compromising the ability of future generations to meet their own needs' (WCED, 1987). A sustainable minerals and energy industry will need to achieve a number of related objectives including greater energy efficiency, improved utilisation of ore deposits, improved utilisation of existing plant, improved product quality, reduction of waste material, reduction of pollution levels and improved safety margins. These objectives all relate in varying degrees to the triple bottom line of economic, social and environmental benefits. One critical component in achieving these objectives is to develop and apply improved control systems across the full range of industry applications from mining to processing and utilisation. However process control relies heavily on the availability of suitable on-line process instrumentation to provide the data and feedback necessary for its implementation. There is a lot of truth in the saying 'if you can't measure it you can't control it'. In the past measurement was achieved by manual sampling followed by sample preparation (such as drying, mixing, crushing and dividing) and off-line laboratory analysis. However this procedure is often subject to significant sampling errors and, most importantly, the measurements are too slow for control purposes. By contrast, on-line analysis can provide rapid and accurate measurement in real time thus opening up new possibilities for improved process control. As a result, there has been a rapid increase in the industrial application of on-line analysis instrumentation over the past few decades. The main purpose of this paper is to briefly review some past Australian developments of on-line analysis systems in the mineral and coal industries and to discuss present developments and future trends

  13. Semi-dwarf mutant lines of hexaploid triticale

    International Nuclear Information System (INIS)

    Pidra, M.

    1989-01-01

    A spring form of hexaploid secondary triticale ADD 143/71, bred by MOGILEVA at the Plant Breeding Station at Uhretice was used for the mutagen treatment. The mutation experiment started in 1979. Seeds were treated with a 0.8 mM water solution of N-methyl-N-nitrosourea (MNH) (CETL and RELICHOVA, unpublished). From 180 M 1 plants, one spike was harvested per plant. A random sample of these seeds was sown as M 2 in 1980 and several plants with shorter main culm were selected. Selfed progenies of eight mutant plants designated ADD 143-m1, ADD 143-m2, ADD 143-m3 etc. were further tested in M 3 and M 4 . There were significant differences in culm length and in some other characters between the original line and the mutant lines. Especially the line m8 looks like a promising source of semi-dwarfness for breeding programmes of hexaploid triticale. During 1985-1987 genetic analysis was performed on the ADD 143/71 and the mutant lines m2, m6, m7 and m8, which suggest that their mutant genes are allelic and recessive

  14. Confirmation of the three-factor model of problematic internet use on off-line adolescent and adult samples.

    Science.gov (United States)

    Koronczai, Beatrix; Urbán, Róbert; Kökönyei, Gyöngyi; Paksi, Borbála; Papp, Krisztina; Kun, Bernadette; Arnold, Petra; Kállai, János; Demetrovics, Zsolt

    2011-11-01

    As the Internet became widely used, problems associated with its excessive use became increasingly apparent. Although for the assessment of these problems several models and related questionnaires have been elaborated, there has been little effort made to confirm them. The aim of the present study was to test the three-factor model of the previously created Problematic Internet Use Questionnaire (PIUQ) by data collection methods formerly not applied (off-line group and face-to-face settings), on the one hand, and by testing on different age groups (adolescent and adult representative samples), on the other hand. Data were collected from 438 high-school students (44.5 percent boys; mean age: 16.0 years; standard deviation=0.7 years) and also from 963 adults (49.9 percent males; mean age: 33.6 years; standard deviation=11.8 years). We applied confirmatory factor analysis to confirm the measurement model of problematic Internet use. The results of the analyses carried out inevitably support the original three-factor model over the possible one-factor solution. Using latent profile analysis, we identified 11 percent of adults and 18 percent of adolescent users characterized by problematic use. Based on exploratory factor analysis, we also suggest a short form of the PIUQ consisting of nine items. Both the original 18-item version of PIUQ and its short 9-item form have satisfactory reliability and validity characteristics, and thus, they are suitable for the assessment of problematic Internet use in future studies.

  15. An extreme Fe II emitter the narrow line quasar PHL 1092

    CERN Document Server

    Bergeron, J

    1980-01-01

    A search for Fe II emission in a sample of radio-quiet quasars has revealed the outstanding properties of PHL 1092. Intense Fe II lines dominate the entire spectrum, and the Fe II UV multiplets are nearly as strong as the optical ones. In contrast the extreme weakness of the Balmer and Mg II lines is striking. For the first time, Fe I lines are identified in an extra-galactic object. The lines are narrow, with a FWHM of 1300 km s/sup -1/. The presence of Fe II UV lines and Fe I lines from the ground state requires moderate column densities. However Fe/sup 0/ can exist only in a region completely shielded from the UV continuum. The weakness of Mg II and H beta relative to Fe II lines is best explained by their thermalization. The emitting region is of high electron density n/sub e/ approximately=10/sup 12/ cm/sup -3/, low temperature T approximately=10000K, and has an optical depth in the Fe II UV lines tau /sub UV/ approximately=10/sup 3/-10/sup 4/. It is speculated that for higher densities all the lines wou...

  16. Hα Emission Line Morphologies in Markarian Starburst Galaxies A ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging Solutions)

    images of a sample of optically selected starburst galaxies from the Markar- ian lists. .... to the size of the galaxy and the histograms were sky dominated. .... simplest qualitative method is to visually examine the distribution of the emission line.

  17. Investigation of Soil Salinity to Distinguish Boundary Line between ...

    African Journals Online (AJOL)

    ADOWIE PERE

    Investigation of Soil Salinity to Distinguish Boundary Line between Saline and ... Setting 4 dSm-1 as the limit between saline and non-saline soils in kriging algorithms resulted in a .... number of sample points within the search window,.

  18. Sampling system for a boiling reactor NPP

    International Nuclear Information System (INIS)

    Zabelin, A.I.; Yakovleva, E.D.; Solov'ev, Yu.A.

    1976-01-01

    Investigations and pilot running of the nuclear power plant with a VK-50 boiling reactor reveal the necessity of normalizing the design system of water sampling and of mandatory replacement of the needle-type throttle device by a helical one. A method for designing a helical throttle device has been worked out. The quantitative characteristics of depositions of corrosion products along the line of reactor water sampling are presented. Recommendations are given on the organizaton of the sampling system of a nuclear power plant with BWR type reactors

  19. Sampling pig farms at the abattoir in a cross-sectional study − Evaluation of a sampling method

    DEFF Research Database (Denmark)

    Birkegård, Anna Camilla; Hisham Beshara Halasa, Tariq; Toft, Nils

    2017-01-01

    slaughter pigs. It was not possible to visit farms within the designated timeframe. Therefore, it was decided to use convenience sampling at the abattoir. Our approach was carried out in three steps: 1) planning: using data from meat inspection to plan at which abattoirs and how many farms to sample; 2......A cross-sectional study design is relatively inexpensive, fast and easy to conduct when compared to other study designs. Careful planning is essential to obtaining a representative sample of the population, and the recommended approach is to use simple random sampling from an exhaustive list...... of units in the target population. This approach is rarely feasible in practice, and other sampling procedures must often be adopted. For example, when slaughter pigs are the target population, sampling the pigs on the slaughter line may be an alternative to on-site sampling at a list of farms. However...

  20. Believing in Your In-Line NDA Instrumentation

    International Nuclear Information System (INIS)

    Hodge, C.A.

    2002-01-01

    A new feature in a processing line at the Savannah River Site (SRS) was the addition of fixed NaI detectors located at strategic points in the processing line. There are many uses of this instrumentation: Process control, MC and A, and criticality safety. In this particular application, there were 23 such strategic points identified. The data can be collected and analyzed in real time at a central point located outside any Radiation Buffer Area. This also allows the data to be collected without sampling or protective equipment requirements. The cost savings in time, cost, and timely production provided by this system are well established. This paper presents an anecdotal story regarding this particular application

  1. Optimization of sampling parameters for standardized exhaled breath sampling.

    Science.gov (United States)

    Doran, Sophie; Romano, Andrea; Hanna, George B

    2017-09-05

    The lack of standardization of breath sampling is a major contributing factor to the poor repeatability of results and hence represents a barrier to the adoption of breath tests in clinical practice. On-line and bag breath sampling have advantages but do not suit multicentre clinical studies whereas storage and robust transport are essential for the conduct of wide-scale studies. Several devices have been developed to control sampling parameters and to concentrate volatile organic compounds (VOCs) onto thermal desorption (TD) tubes and subsequently transport those tubes for laboratory analysis. We conducted three experiments to investigate (i) the fraction of breath sampled (whole vs. lower expiratory exhaled breath); (ii) breath sample volume (125, 250, 500 and 1000ml) and (iii) breath sample flow rate (400, 200, 100 and 50 ml/min). The target VOCs were acetone and potential volatile biomarkers for oesophago-gastric cancer belonging to the aldehyde, fatty acids and phenol chemical classes. We also examined the collection execution time and the impact of environmental contamination. The experiments showed that the use of exhaled breath-sampling devices requires the selection of optimum sampling parameters. The increase in sample volume has improved the levels of VOCs detected. However, the influence of the fraction of exhaled breath and the flow rate depends on the target VOCs measured. The concentration of potential volatile biomarkers for oesophago-gastric cancer was not significantly different between the whole and lower airway exhaled breath. While the recovery of phenols and acetone from TD tubes was lower when breath sampling was performed at a higher flow rate, other VOCs were not affected. A dedicated 'clean air supply' overcomes the contamination from ambient air, but the breath collection device itself can be a source of contaminants. In clinical studies using VOCs to diagnose gastro-oesophageal cancer, the optimum parameters are 500mls sample volume

  2. Characterization of selection effects on broiler lines using DNA fingerprinting

    Directory of Open Access Journals (Sweden)

    GS Schmidt

    2003-05-01

    Full Text Available The objective of this study was to evaluate the effect of selection for body weight on the genetic variability and diversity in broiler lines. Two paternal broiler lines (LL and LLc were used. LL line was selected for 12 generations for growth and carcass and reproduction characteristics. The LLc line was established from LL line in 1985 and mated at random. Blood samples from six chickens per line were collected and used for molecular analysis. Also, a DNA pool was made for each line to compare effects between lines. Data were analyzed considering the collected information on the presence or absence of DNA bands. Band sharing scores were calculated using the DICE coefficient. The pattern of the 21 most representative bands was used. DNA fingerprinting (DFP showed 90.48 % of polymorphism bands for both lines. Difference between lines was not due to the presence or absence of bands, but to the frequency of such bands in each genotype. Considering that both lines had the same genetic background, changes on band frequency were probably due to selection. Selection for body weight had an effect on the band frequency as evaluated by DFP, and for this reason this technique could be used as a tool in the selection process. Results also suggest that bands 4, 5 and 19 were linked to body weight traits, and bands 9, 10, 12, 13 and 21 were linked to reproductive traits such as egg production.

  3. Approaches for on-line coupling of extraction and chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Hyoetylaeinen, Tuulia; Riekkola, Marja-Liisa [Laboratory of Analytical Chemistry, Department of Chemistry, University of Helsinki, P.O. Box 55, 00014, Helsinki (Finland)

    2004-04-01

    This review provides an overview of the approaches available in order to perform on-line coupling of various extraction techniques with liquid and gas chromatography, for the analysis of semivolatile and nonvolatile analytes in liquid and solid samples. The main focus is on the instrumental set-up of these techniques. Selected real applications are described by way of illustration. The extraction methods suitable for on-line coupling covered in this review are: liquid-liquid extraction, solid-phase extraction, membrane-based techniques, pressurised liquid extraction, supercritical fluid extraction, and microwave- and sonication-assisted extractions. The following systems are not covered in this review: on-line coupled solid-phase extraction-liquid chromatography, purge-and-trap-GC, and membrane extraction with a sorbent interface-GC. (orig.)

  4. On-line supercritical fluid extraction-supercritical fluid chromatography-mass spectrometry of polycyclic aromatic hydrocarbons in soil.

    Science.gov (United States)

    Wicker, A Paige; Carlton, Doug D; Tanaka, Kenichiro; Nishimura, Masayuki; Chen, Vivian; Ogura, Tairo; Hedgepeth, William; Schug, Kevin A

    2018-06-01

    On-line supercritical fluid extraction - supercritical fluid chromatography - mass spectrometry (SFE-SFC-MS) has been applied for the determination of polycyclic aromatic hydrocarbons (PAHs) in soil. The purpose of this study was to develop and validate the first on-line SFE-SFC-MS method for the quantification of PAHs in various types of soil. By coupling the sample extraction on-line with chromatography and detection, sample preparation is minimized, diminishing sample loss and contamination, and significantly decreasing the required extraction time. Parameters for on-line extraction coupled to chromatographic analysis were optimized. The method was validated for concentrations of 10-1500 ng of PAHs per gram of soil in Certified Reference Material (CRM) sediment, clay, and sand with R 2  ≥ 0.99. Limits of detection (LOD) were found in the range of 0.001-5 ng/g, and limits of quantification (LOQ) in the range of 5-15 ng/g. The method developed in this study can be effectively applied to the study of PAHs in the environment, and may lay the foundation for further applications of on-line SFE-SFC-MS. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Performance evaluation of the analytical control line for nuclear fuel reprocessing

    International Nuclear Information System (INIS)

    Knobloch, V.; Talas, M.

    1976-01-01

    The analytical line was placed in a five-section semi-hot cell of a total length of 35 m, height of fields 1 m and depth of 75 cm, comprising a manual lift, a sample store, equipment for the opening of the probe vessels, a chemical desk and a desk for preparing the chemical samples for radiometric determination. A two member team worked 6.5 hrs a day making an average of 4.4 chemical determinations and preparing two radiometric determinations. On the basis of experiences gained in this work recommendations are given for the construction of similar installations. A diagram is given of the line and the key parts are shown in figures. (M.K.)

  6. From Off-line to On-line Handwriting Recognition

    NARCIS (Netherlands)

    Lallican, P.; Viard-Gaudin, C.; Knerr, S.

    2004-01-01

    On-line handwriting includes more information on time order of the writing signal and on the dynamics of the writing process than off-line handwriting. Therefore, on-line recognition systems achieve higher recognition rates. This can be concluded from results reported in the literature, and has been

  7. Size optimization for complex permeability measurement of magnetic thin films using a short-circuited microstrip line up to 30 GHz

    Science.gov (United States)

    Takeda, Shigeru; Naoe, Masayuki

    2018-03-01

    High-frequency permeability spectra of magnetic films were measured over a wideband frequency range of 0.1-30 GHz using a shielded and short-circuited microstrip line jig. In this measurement, spurious resonances had to be suppressed up to the highest frequency. To suppress these resonances, characteristic impedance of the microstrip line should approach 50 Ω at the junction between connector and microstrip line. The main factors dominating these resonances were structures of the jig and the sample. The dimensions were optimized in various experiments, and results demonstrated that the frequency could be raised to at least 20 GHz. For the transverse electromagnetic mode to transmit stably along the microstrip line, the preferred sample was rectangular, with the shorter side parallel to the line and the longer side perpendicular to it, and characteristic impedance strongly depended on the signal line width of the jig. However, too small a jig and sample led to a lower S/N ratio.

  8. Distance sampling methods and applications

    CERN Document Server

    Buckland, S T; Marques, T A; Oedekoven, C S

    2015-01-01

    In this book, the authors cover the basic methods and advances within distance sampling that are most valuable to practitioners and in ecology more broadly. This is the fourth book dedicated to distance sampling. In the decade since the last book published, there have been a number of new developments. The intervening years have also shown which advances are of most use. This self-contained book covers topics from the previous publications, while also including recent developments in method, software and application. Distance sampling refers to a suite of methods, including line and point transect sampling, in which animal density or abundance is estimated from a sample of distances to detected individuals. The book illustrates these methods through case studies; data sets and computer code are supplied to readers through the book’s accompanying website.  Some of the case studies use the software Distance, while others use R code. The book is in three parts.  The first part addresses basic methods, the ...

  9. Preparation and applicability of fresh fruit samples for the identification of radiation treatment by EPR

    Energy Technology Data Exchange (ETDEWEB)

    Yordanov, Nicola D. [Laboratory EPR, Institute of Catalysis, Bulgarian Academy of Sciences, 1113 Sofia (Bulgaria)], E-mail: ndyepr@bas.bg; Aleksieva, Katerina [Laboratory EPR, Institute of Catalysis, Bulgarian Academy of Sciences, 1113 Sofia (Bulgaria)

    2009-03-15

    The results of electron paramagnetic resonance (EPR) study on fresh fruits (whole pulp of pears, apples, peaches, apricots, avocado, kiwi and mango) before and after gamma-irradiation are reported using two drying procedures before EPR investigation. In order to remove water from non-irradiated and irradiated samples of the first batch, the pulp of fresh fruits is pressed, and the solid residue is washed with alcohol and dried at room temperature. The fruits of the second batch are pressed and dried in a standard laboratory oven at 40 deg. C. The results obtained with both drying procedures are compared. All samples under study show a singlet EPR line with g=2.0048{+-}0.0005 before irradiation. Irradiation gives rise to typical 'cellulose-like' EPR spectrum featuring one intensive line with g=2.0048{+-}0.0005 and two very weak satellite lines situated 3 mT at left and right of the central line. Only mango samples show a singlet line after irradiation. The fading kinetics of radiation-induced EPR signal is studied for a period of 50 days after irradiation. When the irradiated fruit samples are stored in their natural state and dried just before each EPR measurement, the satellite lines are measurable for less than 17 days of storage. Irradiated fruit samples, when stored dried, lose for 50 days ca. 40% of their radiation-induced radicals if treated with alcohol or ca. 70% if dried in an oven. The reported results unambiguously show that the presence of the satellite lines in the EPR spectra could be used for identification of radiation processing of fresh fruits, thus extending the validity of European Protocol EN 1787 (2000). Foodstuffs-Detection of Irradiated Food Containing Cellulose by EPR Spectroscopy. European Committee for Standardisation. Brussels for dry herbs.

  10. Preparation and applicability of fresh fruit samples for the identification of radiation treatment by EPR

    International Nuclear Information System (INIS)

    Yordanov, Nicola D.; Aleksieva, Katerina

    2009-01-01

    The results of electron paramagnetic resonance (EPR) study on fresh fruits (whole pulp of pears, apples, peaches, apricots, avocado, kiwi and mango) before and after gamma-irradiation are reported using two drying procedures before EPR investigation. In order to remove water from non-irradiated and irradiated samples of the first batch, the pulp of fresh fruits is pressed, and the solid residue is washed with alcohol and dried at room temperature. The fruits of the second batch are pressed and dried in a standard laboratory oven at 40 deg. C. The results obtained with both drying procedures are compared. All samples under study show a singlet EPR line with g=2.0048±0.0005 before irradiation. Irradiation gives rise to typical 'cellulose-like' EPR spectrum featuring one intensive line with g=2.0048±0.0005 and two very weak satellite lines situated 3 mT at left and right of the central line. Only mango samples show a singlet line after irradiation. The fading kinetics of radiation-induced EPR signal is studied for a period of 50 days after irradiation. When the irradiated fruit samples are stored in their natural state and dried just before each EPR measurement, the satellite lines are measurable for less than 17 days of storage. Irradiated fruit samples, when stored dried, lose for 50 days ca. 40% of their radiation-induced radicals if treated with alcohol or ca. 70% if dried in an oven. The reported results unambiguously show that the presence of the satellite lines in the EPR spectra could be used for identification of radiation processing of fresh fruits, thus extending the validity of European Protocol EN 1787 (2000). Foodstuffs-Detection of Irradiated Food Containing Cellulose by EPR Spectroscopy. European Committee for Standardisation. Brussels for dry herbs

  11. Preparation and applicability of fresh fruit samples for the identification of radiation treatment by EPR

    Science.gov (United States)

    Yordanov, Nicola D.; Aleksieva, Katerina

    2009-03-01

    The results of electron paramagnetic resonance (EPR) study on fresh fruits (whole pulp of pears, apples, peaches, apricots, avocado, kiwi and mango) before and after gamma-irradiation are reported using two drying procedures before EPR investigation. In order to remove water from non-irradiated and irradiated samples of the first batch, the pulp of fresh fruits is pressed, and the solid residue is washed with alcohol and dried at room temperature. The fruits of the second batch are pressed and dried in a standard laboratory oven at 40 °C. The results obtained with both drying procedures are compared. All samples under study show a singlet EPR line with g=2.0048±0.0005 before irradiation. Irradiation gives rise to typical "cellulose-like" EPR spectrum featuring one intensive line with g=2.0048±0.0005 and two very weak satellite lines situated 3 mT at left and right of the central line. Only mango samples show a singlet line after irradiation. The fading kinetics of radiation-induced EPR signal is studied for a period of 50 days after irradiation. When the irradiated fruit samples are stored in their natural state and dried just before each EPR measurement, the satellite lines are measurable for less than 17 days of storage. Irradiated fruit samples, when stored dried, lose for 50 days ca. 40% of their radiation-induced radicals if treated with alcohol or ca. 70% if dried in an oven. The reported results unambiguously show that the presence of the satellite lines in the EPR spectra could be used for identification of radiation processing of fresh fruits, thus extending the validity of European Protocol EN 1787 (2000). Foodstuffs—Detection of Irradiated Food Containing Cellulose by EPR Spectroscopy. European Committee for Standardisation. Brussels for dry herbs.

  12. VT Digital Line Graph Miscellaneous Transmission Lines

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) This datalayer is comprised of Miscellaineous Transmission Lines. Digital line graph (DLG) data are digital representations of cartographic...

  13. Evolution of industrial wastewater pollution in the Barcelona Metropolitan Area; Evolucion de la contaminacion industrial en las aguas residuales del area metropolitana de Barcelona

    Energy Technology Data Exchange (ETDEWEB)

    Mantecon Pascual, R.

    2005-07-01

    The Environmental Agency of the Barcelona Metropolitan Area has full powers regarding sewerage. Industrial wastewater emptied into the public sewer system has been monitored and analysed since 1988. the data showing the evolution of the pollution in industrial wastewater are presented, broken down by activities and parameters. These data are based on the analysis of 14,528 samples taken during 19,555 inspections of 5,655 factories. It was found that there has been a gradual improvement in the quality of the effluents. Failure to meet the requirements concerning one or more of the physico-chemical parameters fell from 71% to 39% of the samples analysed. (Author)

  14. Laser-induced Breakdown spectroscopy quantitative analysis method via adaptive analytical line selection and relevance vector machine regression model

    International Nuclear Information System (INIS)

    Yang, Jianhong; Yi, Cancan; Xu, Jinwu; Ma, Xianghong

    2015-01-01

    A new LIBS quantitative analysis method based on analytical line adaptive selection and Relevance Vector Machine (RVM) regression model is proposed. First, a scheme of adaptively selecting analytical line is put forward in order to overcome the drawback of high dependency on a priori knowledge. The candidate analytical lines are automatically selected based on the built-in characteristics of spectral lines, such as spectral intensity, wavelength and width at half height. The analytical lines which will be used as input variables of regression model are determined adaptively according to the samples for both training and testing. Second, an LIBS quantitative analysis method based on RVM is presented. The intensities of analytical lines and the elemental concentrations of certified standard samples are used to train the RVM regression model. The predicted elemental concentration analysis results will be given with a form of confidence interval of probabilistic distribution, which is helpful for evaluating the uncertainness contained in the measured spectra. Chromium concentration analysis experiments of 23 certified standard high-alloy steel samples have been carried out. The multiple correlation coefficient of the prediction was up to 98.85%, and the average relative error of the prediction was 4.01%. The experiment results showed that the proposed LIBS quantitative analysis method achieved better prediction accuracy and better modeling robustness compared with the methods based on partial least squares regression, artificial neural network and standard support vector machine. - Highlights: • Both training and testing samples are considered for analytical lines selection. • The analytical lines are auto-selected based on the built-in characteristics of spectral lines. • The new method can achieve better prediction accuracy and modeling robustness. • Model predictions are given with confidence interval of probabilistic distribution

  15. An opacity-sampled treatment of water vapor

    Science.gov (United States)

    Alexander, David R.; Augason, Gordon C.; Johnson, Hollis R.

    1989-01-01

    Although the bands of H2O are strong in the spectra of cool stars and calculations have repeatedly demonstrated their significance as opacity sources, only approximate opacities are currently available, due both to the difficulty of accounting for the millions of lines involved and to the inadequacy of laboratory and theoretical data. To overcome these obstacles, a new treatment is presented, based upon a statistical representation of the water vapor spectrum derived from available laboratory data. This statistical spectrum of water vapor employs an exponential distribution of line strengths and random positions of lines whose overall properties are forced to reproduce the mean opacities observed in the laboratory. The resultant data set is then treated by the opacity-sampling method exactly as are all other lines, both molecular and atomic. Significant differences are found between the results of this improved treatment and the results obtained with previous treatments of water-vapor opacity.

  16. Controlled chloride cracking of austenitic stainless steel tube samples

    OpenAIRE

    Raseroka, M.S.; Pistorius, P.C.

    2009-01-01

    An experimental rig has been constructed to produce chloride stress corrosion cracks in Type 304L stainless steel tube samples. The samples are to be used to test possible in situ repair methods in future work. The factor which influences the time to failure most strongly is the sample temperature; the distribution of cracks within the sample is affected by local temperature variations and by the position of the water line. Low-frequency oscillations in stress, caused by the on-off temperatur...

  17. Clustering of galaxies around gamma-ray burst sight-lines

    DEFF Research Database (Denmark)

    Sudilovsky, V.; Greiner, J.; Rau, A.

    2013-01-01

    -lines, as strong MgII tends to trace these sources. In this work, we test this expectation by calculating the two point angular correlation function of galaxies within 120'' (~470 h Kpc470h71-1Kpc at z ~ 0.4) of GRB afterglows. We compare the gamma-ray burst optical and near-infrared detector (GROND) GRB afterglow.......3. This result is contrary to the expectations from the MgII excess derived from GRB afterglow spectroscopy, although many confirmed galaxy counterparts to MgII absorbers may be too faint to detect in our sample-especially those at z > 1. We note that the addition of higher sensitivity Spitzer/IRAC or HST/WFC3......There is evidence of an overdensity of strong intervening MgII absorption line systems distributed along the lines of sight toward gamma-ray burst (GRB) afterglows relative to quasar sight-lines. If this excess is real, one should also expect an overdensity of field galaxies around GRB sight...

  18. An integrated and accessible sample data library for Mars sample return science

    Science.gov (United States)

    Tuite, M. L., Jr.; Williford, K. H.

    2015-12-01

    Over the course of the next decade or more, many thousands of geological samples will be collected and analyzed in a variety of ways by researchers at the Jet Propulsion Laboratory (California Institute of Technology) in order to facilitate discovery and contextualize observations made of Mars rocks both in situ and here on Earth if samples are eventually returned. Integration of data from multiple analyses of samples including petrography, thin section and SEM imaging, isotope and organic geochemistry, XRF, XRD, and Raman spectrometry is a challenge and a potential obstacle to discoveries that require supporting lines of evidence. We report the development of a web-accessible repository, the Sample Data Library (SDL) for the sample-based data that are generated by the laboratories and instruments that comprise JPL's Center for Analysis of Returned Samples (CARS) in order to facilitate collaborative interpretation of potential biosignatures in Mars-analog geological samples. The SDL is constructed using low-cost, open-standards-based Amazon Web Services (AWS), including web-accessible storage, relational data base services, and a virtual web server. The data structure is sample-centered with a shared registry for assigning unique identifiers to all samples including International Geo-Sample Numbers. Both raw and derived data produced by instruments and post-processing workflows are automatically uploaded to online storage and linked via the unique identifiers. Through the web interface, users are able to find all the analyses associated with a single sample or search across features shared by multiple samples, sample localities, and analysis types. Planned features include more sophisticated search and analytical interfaces as well as data discoverability through NSF's EarthCube program.

  19. A human monocytic NF-κB fluorescent reporter cell line for detection of microbial contaminants in biological samples.

    Directory of Open Access Journals (Sweden)

    Claire Battin

    Full Text Available Sensing of pathogens by innate immune cells is essential for the initiation of appropriate immune responses. Toll-like receptors (TLRs, which are highly sensitive for various structurally and evolutionary conserved molecules derived from microbes have a prominent role in this process. TLR engagement results in the activation of the transcription factor NF-κB, which induces the expression of cytokines and other inflammatory mediators. The exquisite sensitivity of TLR signalling can be exploited for the detection of bacteria and microbial contaminants in tissue cultures and in protein preparations. Here we describe a cellular reporter system for the detection of TLR ligands in biological samples. The well-characterized human monocytic THP-1 cell line was chosen as host for an NF-ᴋB-inducible enhanced green fluorescent protein reporter gene. We studied the sensitivity of the resultant reporter cells for a variety of microbial components and observed a strong reactivity towards TLR1/2 and TLR2/6 ligands. Mycoplasma lipoproteins are potent TLR2/6 agonists and we demonstrate that our reporter cells can be used as reliable and robust detection system for mycoplasma contaminations in cell cultures. In addition, a TLR4-sensitive subline of our reporters was engineered, and probed with recombinant proteins expressed in different host systems. Bacterially expressed but not mammalian expressed proteins induced strong reporter activity. We also tested proteins expressed in an E. coli strain engineered to lack TLR4 agonists. Such preparations also induced reporter activation in THP-1 cells highlighting the importance of testing recombinant protein preparations for microbial contaminations beyond endotoxins. Our results demonstrate the usefulness of monocytic reporter cells for high-throughput screening for microbial contaminations in diverse biological samples, including tissue culture supernatants and recombinant protein preparations. Fluorescent reporter

  20. SIMULTANEOUS ULTRAVIOLET AND OPTICAL EMISSION-LINE PROFILES OF QUASARS: IMPLICATIONS FOR BLACK HOLE MASS DETERMINATION

    International Nuclear Information System (INIS)

    Ho, Luis C.; Dong Xiaobo; Goldoni, Paolo; Ponti, Gabriele; Greene, Jenny E.

    2012-01-01

    The X-shooter instrument on the Very Large Telescope was used to obtain spectra of seven moderate-redshift quasars simultaneously covering the spectral range ∼3000 Å to 2.5 μm. At z ≈ 1.5, most of the prominent broad emission lines in the ultraviolet to optical region are captured in their rest frame. We use this unique data set, which mitigates complications from source variability, to intercompare the line profiles of C IV λ1549, C III] λ1909, Mg II λ2800, and Hα and evaluate their implications for black hole (BH) mass estimation. We confirm that Mg II and the Balmer lines share similar kinematics and that they deliver mutually consistent BH mass estimates with minimal internal scatter (∼<0.1 dex) using the latest virial mass estimators. Although no virial mass formalism has yet been calibrated for C III], this line does not appear promising for such an application because of the large spread of its velocity width compared to lines of both higher and lower ionization; part of the discrepancy may be due to the difficulty of deblending C III] from its neighboring lines. The situation for C IV is complex and, because of the limited statistics of our small sample, inconclusive. On the one hand, slightly more than half of our sample (4/7) have C IV line widths that correlate reasonably well with Hα line widths, and their respective BH mass estimates agree to within ∼0.15 dex. The rest, on the other hand, exhibit exceptionally broad C IV profiles that overestimate virial masses by factors of 2-5 compared to Hα. As C IV is widely used to study BH demographics at high redshifts, we urgently need to revisit our analysis with a larger sample.

  1. Efficient algorithm for generating spectra using line-by-line methods

    International Nuclear Information System (INIS)

    Sonnad, V.; Iglesias, C.A.

    2011-01-01

    A method is presented for efficient generation of spectra using line-by-line approaches. The only approximation is replacing the line shape function with an interpolation procedure, which makes the method independent of the line profile functional form. The resulting computational savings for large number of lines is proportional to the number of frequency points in the spectral range. Therefore, for large-scale problems the method can provide speedups of two orders of magnitude or more. A method was presented to generate line-by-line spectra efficiently. The first step was to replace the explicit calculation of the profile by the Newton divided-differences interpolating polynomial. The second step is to accumulate the lines effectively reducing their number to the number of frequency points. The final step is recognizing the resulting expression as a convolution and amenable to FFT methods. The reduction in computational effort for a configuration-to-configuration transition array with large number of lines is proportional to the number of frequency points. The method involves no approximations except for replacing the explicit profile evaluation by interpolation. Specifically, the line accumulation and convolution are exact given the interpolation procedure. Furthermore, the interpolation makes the method independent of the line profile functional form contrary to other schemes using FFT methods to generate line-by-line spectra but relying on the analytic form of the profile Fourier transform. Finally, the method relies on a uniform frequency mesh. For non-uniform frequency meshes, however, the method can be applied by using a suitable temporary uniform mesh and the results interpolated onto the final mesh with little additional cost.

  2. Analysis of some coplanar transmission lines: coplanar coupled lines, coplanar coupled striplines, and coplanar coupled lines with rectangular microshield

    Science.gov (United States)

    Yuan, Naichang; He, Jianguo; Yao, Demiao; Dai, Qin; Lin, Weigan

    1995-06-01

    Two types of coplanar transmission lines, rectangular microshield coplanar coupled lines (RMCCL) and coplanar coupled rectangular microshield lines (CCRML), are proposed for MMIC applications. These are developed from coplanar coupled lines (CCL) and coplanar coupled strip lines (CCS). Analytic formulas are presented for calculating the quasistatic TEM parameters of these coupled lines by means of exact conformal mapping techniques. Numerical results are also presented to illustrate the properties of these coplanar transmission lines.

  3. Investigation of Susceptibility of Mycobacterium tuberculosis Complex Strains Isolated from Clinical Samples Against the First and Second-Line Anti-tuberculosis Drugs by the Sensititre MycoTB Plate Method

    Directory of Open Access Journals (Sweden)

    Figen KAYSERİLİ ORHAN

    2018-03-01

    Full Text Available Introduction: Phenotypic methods for drug susceptibility testing of Mycobacterium tuberculosis complex (MTC to second-line drugs are not yet standardized. The Sensititre MycoTB Plate is a microtiter plate containing lyophilized antibiotics and configured for determination of MIC to first and second-line anti-tuberculosis drugs. The purpose of this study is to detect the susceptibility rates of MTC strains isolated from patients’ specimens for first and second-line anti-tuberculosis drugs. Materials and Methods: This study included 50 MTC strains isolated from various clinical specimens. Out of the 50 strains, 38 were isolated from sputum, three from cerebrospinal fluid, three from bronchoalveolar lavage, and six from other samples in this study. The susceptibility of strains to anti-tuberculosis drugs were determined by the Sensititre MycoTB Plate Method. Thawed isolates were subcultured, and dilutions were inoculated into MycoTB wells. The results were read at days 7, 14 and 21. Results: At the end of study, out of 50 MTC isolates, 7 (14% showed resistance to Isoniazid (INH, 5 (10% to streptomycin (SM, 4 (8% to ethambutol (EMB, 4 (8% to ethionamide (ETH, 3 (6% to rifampicin (RIF, 3 (6% to rifabutin (RFB, 2 (4% to kanamycin (KAN, 2 (4% to ofloxacin (OFL, 2 (4% to P-aminosalicyclic acid (PAS, 1 (2% to moxiflocacin (MOX, and 1 (2% to cycloserine (CYC. All strains were found sensitive to amikacin while 2 strains (4% were identified as multidrug-resistant tuberculosis (MDR-TB. Thirty-five strains (70% were sensitive to all drugs. Extensively drug resistant tuberculosis (XDR-TB was not determined in this study. Conclusion: This is the first study that tests second line anti-tuberculosis drugs in our location and provides us valuable data regarding MDR-TB and XDR-TB rates. The Sensititre MycoTB Plate Method is a fast, reliable and practical method and can be used to determine the susceptibility of first and second-line anti-tuberculosis drugs.

  4. Sampling and measurement of long-lived radionuclides in environmental samples

    International Nuclear Information System (INIS)

    Brauer, F.P.; Goles, R.W.; Kaye, J.H.; Rieck, H.G. Jr.

    1977-01-01

    The volatile and semivolatile long-lived man-made radionuclides 3 H, 14 C, 79 Se, 85 Kr, 99 Tc, 129 I, 135 Cs, and 137 Cs are of concern in operation of nuclear facilities because they are difficult and expensive to contain and once emitted to the environment they become permanent ecological constituents with both local and global distributions. Species-selective sampling and analytical methods (radiochemical, neutron activation, and mass spectrometric) have been developed for many of these nuclides with sensitivities well below those required for radiation protection. These sampling and analytical methods have been applied to the measurement of current environmental levels of some of the more ecologically important radionuclides. The detection and tracing of long-lived radionuclides is being conducted in order to establish base-line values and to study environmental behavior. This paper describes detection and measurement techniques and summarizes current measurement results

  5. Physical and Chemical Characterization of Fat and Oil Deposits in Mashhad City Sewer Lines and the Solutions Developed

    Directory of Open Access Journals (Sweden)

    Mahdi kamali

    2017-01-01

    Full Text Available Formation of oil, fat, and grease deposits in sewer pipelines is a major concern as they result in sewage overflow and pose health problems. Analysis of two sample deposits collected from the sewer lines of Imam Reza Street in the city of Mashhad suggested that the chemical reactions promoted by edible oils in the sewer lines lead to the formation of insoluble soap and deposits. Being sticky, the deposits accumulate over time to eventually block the lines. The analysis also showed that the moisture content of the samples ranged between 50‒62%, indicating that water does not play a main role in their formation. The samples were also found to contain 61.78% and 84.35% saturated fatty acids, with palmitic acid being the dominant one. Calcium was the main metal in the samples, which is due to both water hardness and corrosion of the sewer lines. Based on the results obtained, the origin of these deposits, and the relevant protocols for the management of oil and fat wastes, solutions were proposed to prevent deposit formation and sewer line clogging that suit the special cultural and environmental conditions of the city. These proposals are under consideration for implementation in the region.

  6. Impact of lining material on chemical and microbial irrigation water quality of Nubaria canal, Egypt

    Directory of Open Access Journals (Sweden)

    Ahmed Mohamed Azzam

    2016-02-01

    Full Text Available Objective: To assess the effect of lining material (cement of Nubaria canal (Beheira Governorate, Egypt on its water quality. Methods: Trace metal ions (Fe, Zn, Cu, Pb, and Cd and bacterial indictors for water samples collected from two types of stations (lined and unlined during successive four seasons were analyzed. The effect of lining on bacterial indicators; total viable bacterial count at 22 and 37 °C, total coliform, fecal coliform and fecal streptococci and presence of some bacterial species were studied. Results: Bacterial indicators and trace metals showed seasonal variations, where the highest values were recorded during summer. A significant reduction for Cu (P < 0.05, Zn (P < 0.01 and Cd (P < 0.001 was recorded in lined stations compared to those of unlined ones. Bacterial indicators recorded the lowest counts in lined stations during all seasons, while there was a significant reduction (P < 0.05 between total coliform values (1.70 ± 0.50 in lined stations and unlined ones (3.57 ± 1.01 during summer. Escherichia coli bacteria were predominant in water samples of Nubaria canal, where it recorded 34.4% of bacterial isolates. Conclusions: Lined material plays a role for reducing the bacterial growth and metals concentration, therefore the lining of canal helps in preventing the discharge of sewage pollution into canal.

  7. Mechanical properties of the weld line defect in micro injection molding for various nano filled polypropylene composites

    International Nuclear Information System (INIS)

    Xie Lei; Ziegmann, Gerhard

    2011-01-01

    Research highlights: → PP/CNFs and PP/TiO 2 composites with relative high loading fractions (10, 20, 30 and 35 wt%) were fabricated by inner melt mixing process. Micro tensile test samples were formed by injection molding combined with variotherm process for all composites. → The morphological properties of all nano composites were characterized by WXRD, whose results imply the adding nano fillers did not change the crystal form of PP, but the crystallites size and distance between lattices of crystals were changed with various nano fillers and loading fractions. → DSC analysis show that due to the nucleating function of nano fillers, the peak temperature of crystallization was increased and the peak temperature of crystallization melting was decreased by adding the nanofillers. → The flow ability of nano composites was tested by high pressure single capillary rheometer and the results demonstrate that nano fillers increased the viscosity of PP matrix. → Based on these significant information and analysis foundation of the nano filled composites, the micro weld line samples were formed by injection molding process and characterized by tensile test method. From the achieved results, it can be found that in general, for functional nano filled polymer composites, the mechanical property of micro weld lines were obviously influenced by nano fillers' shape and loading fractions. → The E modulus of micro weld line was increased due to loading CNFs in PP matrix, while the elongation of the micro tensile samples with weld line is considerably decreased comparing with those of unfilled PP samples. The detrimental tensile strength of micro weld lines were observed when CNFs contents increasing, except for at a 10 wt%. → For TiO 2 nano particles filled PP, due to the poor dispersion of nano particles, at low loading fraction of 10 wt%, the E modulus and tensile strength of micro weld lines were decreased by filling nano particles, but when the loading fraction

  8. Microplastic sampling in the Mediterranean Sea

    DEFF Research Database (Denmark)

    Biginagwa, Fares; Sosthenes, Bahati; Syberg, Kristian

    The extent of microplastic pollution in the Southwestern Mediterranean Sea is not yet known, although on Northwestern part has been previously studied. Plastic samples were collected at 7 transects during a 10 day expedition from Sicily (Italy) to Malaga (Spain) in September 2014. A 330 µM mesh...... manta trawl was used for surface water sampling. Physical and chemical characterization of plastic particles was performed with regard to size (1-5mm), shape (fragment, line, thin film, foam and pellets), color (transparent, white, black and colored), density and chemical composition according...

  9. Pharmacokinetics of first-line tuberculosis drugs in tanzanian patients

    NARCIS (Netherlands)

    Tostmann, A.; Mtabho, C.M.; Semvua, H.H.; Boogaard, J. van den; Kibiki, G.S.; Boeree, M.J.; Aarnoutse, R.E.

    2013-01-01

    East Africa has a high tuberculosis (TB) incidence and mortality, yet there are very limited data on exposure to TB drugs in patients from this region. We therefore determined the pharmacokinetic characteristics of first-line TB drugs in Tanzanian patients using intensive pharmacokinetic sampling.

  10. SIMS analysis using a new novel sample stage

    International Nuclear Information System (INIS)

    Miwa, Shiro; Nomachi, Ichiro; Kitajima, Hideo

    2006-01-01

    We have developed a novel sample stage for Cameca IMS-series instruments that allows us to adjust the tilt of the sample holder and to vary the height of the sample surface from outside the vacuum chamber. A third function of the stage is the capability to cool sample to -150 deg. C using liquid nitrogen. Using this stage, we can measure line profiles of 10 mm in length without any variation in the secondary ion yields. By moving the sample surface toward the input lens, the primary ion beam is well focused when the energy of the primary ions is reduced. Sample cooling is useful for samples such as organic materials that are easily damaged by primary ions or electrons

  11. SIMS analysis using a new novel sample stage

    Energy Technology Data Exchange (ETDEWEB)

    Miwa, Shiro [Materials Analysis Lab., Sony Corporation, 4-16-1 Okata, Atsugi 243-0021 (Japan)]. E-mail: Shiro.Miwa@jp.sony.com; Nomachi, Ichiro [Materials Analysis Lab., Sony Corporation, 4-16-1 Okata, Atsugi 243-0021 (Japan); Kitajima, Hideo [Nanotechnos Corp., 5-4-30 Nishihashimoto, Sagamihara 229-1131 (Japan)

    2006-07-30

    We have developed a novel sample stage for Cameca IMS-series instruments that allows us to adjust the tilt of the sample holder and to vary the height of the sample surface from outside the vacuum chamber. A third function of the stage is the capability to cool sample to -150 deg. C using liquid nitrogen. Using this stage, we can measure line profiles of 10 mm in length without any variation in the secondary ion yields. By moving the sample surface toward the input lens, the primary ion beam is well focused when the energy of the primary ions is reduced. Sample cooling is useful for samples such as organic materials that are easily damaged by primary ions or electrons.

  12. Efficient Sample Tracking With OpenLabFramework

    DEFF Research Database (Denmark)

    List, Markus; Schmidt, Steffen; Trojnar, Jakub

    2014-01-01

    of samples created and need to be replaced with state-of-the-art laboratory information management systems. Such systems have been developed in large numbers, but they are often limited to specific research domains and types of data. One domain so far neglected is the management of libraries of vector clones...... and genetically engineered cell lines. OpenLabFramework is a newly developed web-application for sample tracking, particularly laid out to fill this gap, but with an open architecture allowing it to be extended for other biological materials and functional data. Its sample tracking mechanism is fully customizable...

  13. Emission-line galaxies toward the booetes void

    International Nuclear Information System (INIS)

    Moody, J.W.

    1986-01-01

    Galaxies with strong emission are potentially useful as probes of the large-scale galaxian distribution. However, to serve as probes, their relative frequency and clustering properties must be known. This dissertation presents a study of these properties for field galaxies having [OIII] λ5007 emission equivalent widths greater than 10 A and reports on a search for galaxies with [OIII] λ5007 emission in the direction of the Booetes void, a volume located at α = 4/sup h/48/sup m/, δ = 47 0 , and cz = 15,000 km/sec that has been demonstrated to be under-abundant in galaxies by a factor of at least four. The study of field emission-line galaxies was done in two magnitude limited surveys consisting of 341 galaxies from both the north and south galactic caps having previously published redshifts and photometry. The galaxy spectra used for redshifts were examined and supplemented by new observations for 56 objects, primarily those with confirmed or suspected emission. Emission-line galaxies were found to comprise 8.8% of galaxies in a Illa-J selected sample or 6.6% of galaxies in a Illa-F selected sample. A search for emission-line galaxies towards the Booetes void was undertaken using the Burrell Schmidt telescope and an objective prism giving a reciprocal dispersion of 900 A/mm at Hβ. Three galaxies were found to lie within it, a result consistent with distributions through the void ranging from uniform to under-abundant by a factor of three

  14. The development of an on-line gold analyser

    International Nuclear Information System (INIS)

    Robert, R.V.D.; Ormrod, G.T.W.

    1982-01-01

    An on-line analyser to monitor the gold in solutions from the carbon-in-pulp process is described. The automatic system is based on the delivery of filtered samples of the solutions to a distribution valve for measurement by flameless atomic-absorption spectrophotometry. The samples is introduced by the aerosol-deposition method. Operation of the analyser on a pilot plant and on a full-scale carbon-in-pulp plant has shown that the system is economically feasible and capable of providing a continuous indication of the efficiency of the extraction process

  15. Do quasar ley lines really exist

    International Nuclear Information System (INIS)

    Webster, A.

    1982-01-01

    The hypothesis that the distribution of the quasars on the celestial sphere contains an unexpectedly large number of well-aligned triples is tested by applying, to the Cerro Tololo objective-prism sample, a shape-statistic which was originally developed to investigate whether neolithic standing stones were deliberately sited on ley lines. It is found that alignment in triples is not a conspicuous feature of the quasars in this sample. The sample does contain one well aligned triple whose properties resemble those of two triples found earlier in a different field by earlier authors, but the probability of this being a chance alignment is not low. The same authors have noted a total of four well-collimated triples which they consider remarkable, but an approximate probability calculation based on the shape-statistic indicates that they need not have a low probability of occurring by chance. (author)

  16. Malaria rapid diagnostic tests: Plasmodium falciparum infections with high parasite densities may generate false positive Plasmodium vivax pLDH lines

    Directory of Open Access Journals (Sweden)

    van Esbroeck Marjan

    2010-07-01

    Full Text Available Abstract Background Most malaria rapid diagnostic tests (RDTs detect Plasmodium falciparum and an antigen common to the four species. Plasmodium vivax-specific RDTs target P. vivax-specific parasite lactate dehydrogenase (Pv-pLDH. Previous observations of false positive Pv-pLDH test lines in P. falciparum samples incited to the present study, which assessed P. vivax-specific RDTs for the occurrence of false positive Pv-pLDH lines in P. falciparum samples. Methods Nine P. vivax-specific RDTs were tested with 85 P. falciparum samples of high (≥2% parasite density. Mixed P. falciparum/P. vivax infections were ruled out by real-time PCR. The RDTs included two-band (detecting Pv-pLDH, three-band (detecting P. falciparum-antigen and Pv-pLDH and four-band RDTs (detecting P. falciparum, Pv-pLDH and pan-pLDH. Results False positive Pv-pLDH lines were observed in 6/9 RDTs (including two- three- and four-band RDTs. They occurred in the individual RDT brands at frequencies ranging from 8.2% to 29.1%. For 19/85 samples, at least two RDT brands generated a false positive Pv-pLDH line. Sixteen of 85 (18.8% false positive lines were of medium or strong line intensity. There was no significant relation between false positive results and parasite density or geographic origin of the samples. Conclusion False positive Pv-pLDH lines in P. falciparum samples with high parasite density occurred in 6/9 P. vivax-specific RDTs. This is of concern as P. falciparum and P. vivax are co-circulating in many regions. The diagnosis of life-threatening P. falciparum malaria may be missed (two-band Pv-pLDH RDT, or the patient may be treated incorrectly with primaquine (three- or four-band RDTs.

  17. Optimization of line configuration and balancing for flexible machining lines

    Science.gov (United States)

    Liu, Xuemei; Li, Aiping; Chen, Zurui

    2016-05-01

    Line configuration and balancing is to select the type of line and allot a given set of operations as well as machines to a sequence of workstations to realize high-efficiency production. Most of the current researches for machining line configuration and balancing problems are related to dedicated transfer lines with dedicated machine workstations. With growing trends towards great product variety and fluctuations in market demand, dedicated transfer lines are being replaced with flexible machining line composed of identical CNC machines. This paper deals with the line configuration and balancing problem for flexible machining lines. The objective is to assign operations to workstations and find the sequence of execution, specify the number of machines in each workstation while minimizing the line cycle time and total number of machines. This problem is subject to precedence, clustering, accessibility and capacity constraints among the features, operations, setups and workstations. The mathematical model and heuristic algorithm based on feature group strategy and polychromatic sets theory are presented to find an optimal solution. The feature group strategy and polychromatic sets theory are used to establish constraint model. A heuristic operations sequencing and assignment algorithm is given. An industrial case study is carried out, and multiple optimal solutions in different line configurations are obtained. The case studying results show that the solutions with shorter cycle time and higher line balancing rate demonstrate the feasibility and effectiveness of the proposed algorithm. This research proposes a heuristic line configuration and balancing algorithm based on feature group strategy and polychromatic sets theory which is able to provide better solutions while achieving an improvement in computing time.

  18. LINE FUSION GENES: a database of LINE expression in human genes

    Directory of Open Access Journals (Sweden)

    Park Hong-Seog

    2006-06-01

    Full Text Available Abstract Background Long Interspersed Nuclear Elements (LINEs are the most abundant retrotransposons in humans. About 79% of human genes are estimated to contain at least one segment of LINE per transcription unit. Recent studies have shown that LINE elements can affect protein sequences, splicing patterns and expression of human genes. Description We have developed a database, LINE FUSION GENES, for elucidating LINE expression throughout the human gene database. We searched the 28,171 genes listed in the NCBI database for LINE elements and analyzed their structures and expression patterns. The results show that the mRNA sequences of 1,329 genes were affected by LINE expression. The LINE expression types were classified on the basis of LINEs in the 5' UTR, exon or 3' UTR sequences of the mRNAs. Our database provides further information, such as the tissue distribution and chromosomal location of the genes, and the domain structure that is changed by LINE integration. We have linked all the accession numbers to the NCBI data bank to provide mRNA sequences for subsequent users. Conclusion We believe that our work will interest genome scientists and might help them to gain insight into the implications of LINE expression for human evolution and disease. Availability http://www.primate.or.kr/line

  19. An on-line tritium-in-water monitor

    International Nuclear Information System (INIS)

    Singh, A.N.; Ratnakaran, M.; Vohra, K.G.

    1985-01-01

    The paper describes the development and operation of a continuous on-line tritium-in-water monitor for the detection of heavy water leaks into the secondary coolant light water of a heavy water power reactor. The heart of the instrument is its plastic scintillator sponge detector, made from 5 μm thick plastic scintillator films. The sponge weighs only about 1 g and is in the form of disc of 48 mm diameter and 8 mm thickness. The total surface area of the films is about 3000 cm 2 . In the coincidence mode of counting, the detector gives 1000 cps for the passage of 3.7 x 10 4 Bq/cm 3 (1 μCi/cm 3 ) of tritiated water. The background in 6 cm thick lead shielding in the laboratory is 0.2 cps, and inside the reactor building it is below 1 cps. The monitor presently scans 18 sample lines in sequence for 5 min each and gives a printout for the activity in each line. (orig.)

  20. An on-line tritium-in-water monitor

    Science.gov (United States)

    Singh, A. N.; Ratnakaran, M.; Vohra, K. G.

    1985-05-01

    The paper describes the development and operation of a continuous on-line tritium-in-water monitor for the detection of heavy water leaks into the secondary coolant light water of a heavy water power reactor. The heart of the instrument is its plastic scintillator sponge detector, made from 5 μm thick plastic scintillator films. The sponge weighs only about 1 g and is in the form of disc of 48 mm diameter and 8 mm thickness. The total surface area of the films is about 3000 cm 2. In the coincidence mode of counting, the detector gives 1000 cps for the passage of 3.7 × 10 4 Bq/cm 3 (1 μCi/cm 3) of tritiated water. The background in 6 cm thick lead shielding in the laboratory is 0.2 cps, and inside the reactor building it is below 1 cps. The monitor presently scans 18 sample lines in sequence for 5 min each and gives a printout for the activity in each line.

  1. Analysis of cement solidified product and ash samples and preparation of a reference material

    International Nuclear Information System (INIS)

    Ishimori, Ken-ichiro; Haraga, Tomoko; Shimada, Asako; Kameo, Yutaka; Takahashi, Kuniaki

    2010-08-01

    Simple and rapid analytical methods for radionuclides in low-level radioactive waste have been developed by the present authors. The methods were applied to simulated solidified products and actual metal wastes to confirm their usefulness. The results were summarized as analytical guide lines. In the present work, cement solidified product and ash waste were analyzed followed by the analytical guide lines and subjects were picked up and solved for the application of the analytical guide lines to these wastes. Pulverization and homogenization method for ash waste was improved to prevent a contamination since the radioactivity concentrations of the ash samples were relatively high. Pre-treatment method was altered for the cement solidified product and ash samples taking account for their high concentration of Ca. Newly, an analytical method was also developed to measure 129 I with a dynamic reaction cell inductively coupled plasma mass spectrometer. In the analytical test based on the improved guide lines, gamma-ray emitting nuclides, 60 Co and 137 Cs, were measured to estimate the radioactivity of the other alpha and beta-ray emitting nuclides. The radionuclides assumed detectable, 3 H, 14 C, 36 Cl, 63 Ni, 90 Sr, and alpha-ray emitting nuclides, were analyzed with the improved analytical guide lines and their applicability for cement solidified product and ash samples were confirmed. Additionally a cement solidified product sample was evaluated in terms of the homogeneity and the radioactivity concentrations in order to prepare a reference material for radiochemical analysis. (author)

  2. THE LOCAL [C ii] 158 μ m EMISSION LINE LUMINOSITY FUNCTION

    Energy Technology Data Exchange (ETDEWEB)

    Hemmati, Shoubaneh; Yan, Lin; Capak, Peter; Faisst, Andreas; Masters, Daniel [Infrared Processing and Analysis Center, Department of Astronomy, California Institute of Technology, 1200 E. California Blvd., Pasadena CA 91125 (United States); Diaz-Santos, Tanio [Nucleo de Astronomia de la Facultad de Ingenieria, Universidad Diego Portales, Av. Ejercito Libertador 441, Santiago (Chile); Armus, Lee, E-mail: shemmati@ipac.caltech.edu [Spitzer Science Center, Department of Astronomy, California Institute of Technology, 1200 E. California Blvd., Pasadena, CA 91125 (United States)

    2017-01-01

    We present, for the first time, the local [C ii] 158 μ m emission line luminosity function measured using a sample of more than 500 galaxies from the Revised Bright Galaxy Sample. [C ii] luminosities are measured from the Herschel PACS observations of the Luminous Infrared Galaxies (LIRGs) in the Great Observatories All-sky LIRG Survey and estimated for the rest of the sample based on the far-infrared (far-IR) luminosity and color. The sample covers 91.3% of the sky and is complete at S{sub 60μm} > 5.24 Jy. We calculate the completeness as a function of [C ii] line luminosity and distance, based on the far-IR color and flux densities. The [C ii] luminosity function is constrained in the range ∼10{sup 7–9} L{sub ⊙} from both the 1/ V{sub max} and a maximum likelihood methods. The shape of our derived [C ii] emission line luminosity function agrees well with the IR luminosity function. For the CO(1-0) and [C ii] luminosity functions to agree, we propose a varying ratio of [C ii]/CO(1-0) as a function of CO luminosity, with larger ratios for fainter CO luminosities. Limited [C ii] high-redshift observations as well as estimates based on the IR and UV luminosity functions are suggestive of an evolution in the [C ii] luminosity function similar to the evolution trend of the cosmic star formation rate density. Deep surveys using the Atacama Large Millimeter Array with full capability will be able to confirm this prediction.

  3. Developing a sustainable energy strategy for a water utility. Part I: A review of the UK legislative framework.

    Science.gov (United States)

    Zakkour, P D; Gaterell, M R; Griffin, P; Gochin, R J; Lester, J N

    2002-10-01

    Increasing political effort to improve water quality across the UK and Europe has led to water and sewerage companies investing heavily in high-tech wastewater treatment plants capable of producing high quality effluents. Consequently, amounts of bought-in electricity used for wastewater treatment has and will continue to increase significantly over coming years, while greater provision of enhanced sewage treatment also produces greater volumes of sewage sludge requiring treatment and disposal. Over the same period, tougher controls on the quality of biosolids applied to agricultural land have also been introduced, while there has been an international attempt to reduce the use of fossil-fuel derived power sources because of concerns over global warming. The latter has brought about the introduction of financial instruments, such as the Climate Change Levy, to curb energy use, promote energy efficiency and encourage the development of renewable energy technologies. These factors are set to drive-up the costs of providing adequate sewage treatment services, while at the same time, a tough regulatory line taken to control profits on regional monopolies held by the UK water companies will significantly reduce their revenues over the period 2000-05. The result is that, financially, UK water and sewerage companies face their most challenging period since privatisation in 1989. This paper briefly outlines the current regulations relating to water quality and energy use that will affect water company operations over coming years.

  4. The Lyα Reference Sample

    DEFF Research Database (Denmark)

    Ostlin, Goran; Hayes, Matthew; Duval, Florent

    2014-01-01

    The Lyα Reference Sample (LARS) is a substantial program with the Hubble Space Telescope (HST) that provides a sample of local universe laboratory galaxies in which to study the detailed astrophysics of the visibility and strength of the Lyαline of neutral hydrogen. Lyα is the dominant spectral...... are produced (whether or not they escape), we demanded an Hα equivalent width W(Hα) ≥100 Å. The final sample of 14 galaxies covers far-UV (FUV, λ ~ 1500 Å) luminosities that overlap with those of high-z Lyα emitters (LAEs) and Lyman break galaxies (LBGs), making LARS a valid comparison sample. We present......) but strongly asymmetric Lyα emission. Spectroscopy from the Cosmic Origins Spectrograph on board HST centered on the brightest UV knot shows a moderate outflow in the neutral interstellar medium (probed by low ionization stage absorption features) and Lyα emission with an asymmetric profile. Radiative transfer...

  5. Mudflow utilization for construction materials of tertiary irrigation canal lining

    Science.gov (United States)

    Azis, Subandiyah; Kustamar

    2017-11-01

    Mudflow in Siring Village, Sidoarjo Regency, Indonesia, has been in eruption since May 29, 2006. It still shows irregular large bursts which loaded in a sludge reservoir with capacity of 59 million m3. From 2007 until 2015, there were more than 20 studies which concluded that the mudflow could be used as a mixture of building materials. However, the studies were not detailed and needed further research. This research aims to investigate the use of mudflow as tertiary irrigation canal lining material. This research comes with several laboratory tests to obtain a mixture that is solid and water-resistant. The methods that were used are descriptive methods as follows: 1). Sampling of mudflow, to be analyzed in Material Testing Laboratory. 2). Sampling of soil at research site, to be analyzed in Soil Mechanics Laboratory 3). Mixing of materials which are consist of mudflow and other materials and doing strength test in the laboratory. 4). Installation of tertiary irrigation canal lining using materials that have been tested. 5). Observation of lining's strength inactive soil pressure-bearing and its impermeability. It is expected that the results of this research will be applied extensively throughout the tertiary irrigation canals, so mudflow can be utilized as raw materials that are environmentally friendly, which are able to help preserving the environment, also to reduce the removal of sand / rock in the river, which has been used for lining materials, that benefits in preventing damage to the river ecosystem.

  6. Durée de vie des réseaux d’assainissement, modélisation Service life in sewerage system, simulation

    Directory of Open Access Journals (Sweden)

    Jauberthie R.

    2012-09-01

    utilisons les techniques les plus récentes d’estimation ensembliste afin de diagnostiquer ces éléments. Une attention particulière est portée sur l’estimation du niveau de corrosion permettant d’envisager la programmation d’une réfection totale ou partielle. Building models of physical systems turns out to be an awkward task by the presence of noise and disturbance. It is not always possible to get information about disturbances and noises acting on the system. This may turn the usual stochastic framework inappropriate. In such cases, assuming bounded uncertainties may be a solution. An interesting way to go is then to use guaranteed estimation methods, which learn the state and/or parameters of the models from data. The set-membership models are well suited for fault detection and for making relevant diagnoses to improve the process evolution. A damage analysis of sewerage structures in Rennes (France is undertaken. These systems (unit network rainwater and wastewater or separate system consist of cement-based materials. The damage is quantified through various indicators of material properties (material extracted in the city. One hundred samples characterized by different streets and laying dates between 1892 and our days are analyzed. Thus, in this work, starting from a set-membership model of the behaviour of different sections of pipe wastewater, we use recent techniques of set-membership estimation to model and diagnose the system. A particular attention is paid to estimating the corrosion level for considering the full or partial rehabilitation.

  7. Mechanical Conversion for High-Throughput TEM Sample Preparation

    International Nuclear Information System (INIS)

    Kendrick, Anthony B; Moore, Thomas M; Zaykova-Feldman, Lyudmila

    2006-01-01

    This paper presents a novel method of direct mechanical conversion from lift-out sample to TEM sample holder. The lift-out sample is prepared in the FIB using the in-situ liftout Total Release TM method. The mechanical conversion is conducted using a mechanical press and one of a variety of TEM coupons, including coupons for both top-side and back-side thinning. The press joins a probe tip point with attached TEM sample to the sample coupon and separates the complete assembly as a 3mm diameter TEM grid, compatible with commercially available TEM sample holder rods. This mechanical conversion process lends itself well to the high through-put requirements of in-line process control and to materials characterization labs where instrument utilization and sample security are critically important

  8. Quasi-elastic neutron line broadening in nematic liquid crystals

    International Nuclear Information System (INIS)

    Cvikl, B.; Dimic, V.; Dusic, M.; Kristof, E.; Srebotnjak, E.

    1979-01-01

    On the basis of a new random walk torsional oscillations model of the amplitude φ 0 of rigid flat molecules a quasi-elastic neutron line broadening has been calculated and the results compared to the measurements obtained on the sample of cholesteryl propionate. A good agreement was obtained. (author)

  9. Transmission Line Series Compensation for Wind Energy Transmission

    International Nuclear Information System (INIS)

    Palanichamy, C; Wong, Y C

    2015-01-01

    Wind energy has demonstrated to be a clean, copious and absolutely renewable source of energy, and the large penetration of it into the power grid indicates that wind energy is considered an effective means of power generation, Transmission of wind energy from remote locations to load centers necessitates long transmission lines. Series compensation is a proven and economical transmission solution to address system power transfer strength, grid stability, and voltage profile issues of long transmission lines. In this paper, a programmable approach to determine the capacitive reactance of series capacitor and optimum location for its placement to achieve maximum power transfer gas been presented. The respective program with sample solutions has been provided for real-time applications. (paper)

  10. Towards quantitative laser-induced breakdown spectroscopy analysis of soil samples

    International Nuclear Information System (INIS)

    Bousquet, B.; Sirven, J.-B.; Canioni, L.

    2007-01-01

    A quantitative analysis of chromium in soil samples is presented. Different emission lines related to chromium are studied in order to select the best one for quantitative features. Important matrix effects are demonstrated from one soil to the other, preventing any prediction of concentration in different soils on the basis of a univariate calibration curve. Finally, a classification of the LIBS data based on a series of Principal Component Analyses (PCA) is applied to a reduced dataset of selected spectral lines related to the major chemical elements in the soils. LIBS data of heterogeneous soils appear to be widely dispersed, which leads to a reconsideration of the sampling step in the analysis process

  11. Experimental analysis of a TEM plane transmission line for DNA studies at 900 MHz EM fields

    International Nuclear Information System (INIS)

    Belloni, F; Doria, D; Lorusso, A; Nassisi, V; Velardi, L; Alifano, P; Monaco, C; Tala, A; Tredici, M; Raino, A

    2006-01-01

    A suitable plane transmission line was developed and its behaviour analysed at 900 MHz radiofrequency fields to study DNA mutability and the repair of micro-organisms. In this work, utilizing such a device, we investigated the behaviour of DNA mutability and repair of Escherichia coli strains. The transmission line was very simple and versatile in changing its characteristic resistance and field intensity by varying its sizes. In the absence of cell samples inside the transmission line, the relative modulation of the electric and/or magnetic field was ±31% with respect to the mean values, allowing the processing of more samples at different exposure fields in a single run. A slight decrease in spontaneous mutability to rifampicin-resistance of the E. coli JC411 strain was demonstrated in mismatch-repair proficient samples exposed to the radio-frequency fields during their growth on solid medium

  12. On-line monitoring of monoclonal antibody formation in high density perfusion culture using FIA.

    Science.gov (United States)

    Fenge, C; Fraune, E; Freitag, R; Scheper, T; Schügerl, K

    1991-05-01

    An automated flow injection system for on-line analysis of proteins in real fermentation fluids was developed by combining the principles of stopped-flow, merging zones flow injection analysis (FIA) with antigen-antibody reactions. IgG in the sample reacted with its corresponding antibody (a-IgG) in the reagent solution. Formation of insoluble immunocomplexes resulted in an increase of the turbidity which was determined photometrically. This system was used to monitor monoclonal antibody production in high cell density perfusion culture of hybridoma cells. Perfusion was performed with a newly developed static filtration unit equipped with hydrophilic microporous tubular membranes. Different sampling devices were tested to obtain a cell-free sample stream for on-line product analysis of high molecular weight (e.g., monoclonal antibodies) and low molecular weight (e.g., glucose, lactate) medium components. In fermentation fluids a good correlation (coefficient: 0.996) between the FIA method and an ELISA test was demonstrated. In a high density perfusion cultivation process mAb formation was successfully monitored on-line over a period of 400 h using a reliable sampling system. Glucose and lactate were measured over the same period of time using a commercially available automatic analyser based on immobilized enzyme technology.

  13. Determination of As(III) and total inorganic As in water samples using an on-line solid phase extraction and flow injection hydride generation atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Sigrist, Mirna; Albertengo, Antonela; Beldomenico, Horacio; Tudino, Mabel

    2011-01-01

    A simple and robust on-line sequential injection system based on solid phase extraction (SPE) coupled to a flow injection hydride generation atomic absorption spectrometer (FI-HGAAS) with a heated quartz tube atomizer (QTA) was developed and optimized for the determination of As(III) in groundwater without any kind of sample pretreatment. The method was based on the selective retention of inorganic As(V) that was carried out by passing the filtered original sample through a cartridge containing a chloride-form strong anion exchanger. Thus the most toxic form, inorganic As(III), was determined fast and directly by AsH 3 generation using 3.5 mol L -1 HCl as carrier solution and 0.35% (m/v) NaBH 4 in 0.025% NaOH as the reductant. Since the uptake of As(V) should be interfered by several anions of natural occurrence in waters, the effect of Cl - , SO 4 2- , NO 3 - , HPO 4 2- , HCO 3 - on retention was evaluated and discussed. The total soluble inorganic arsenic concentration was determined on aliquots of filtered samples acidified with concentrated HCl and pre-reduced with 5% KI-5% C 6 H 8 O 6 solution. The concentration of As(V) was calculated by difference between the total soluble inorganic arsenic and As(III) concentrations. Detection limits (LODs) of 0.5 μg L -1 and 0.6 μg L -1 for As(III) and inorganic total As, respectively, were obtained for a 500 μL sample volume. The obtained limits of detection allowed testing the water quality according to the national and international regulations. The analytical recovery for water samples spiked with As(III) ranged between 98% and 106%. The sampling throughput for As(III) determination was 60 samples h -1 . The device for groundwater sampling was especially designed for the authors. Metallic components were avoided and the contact between the sample and the atmospheric oxygen was carried to a minimum. On-field arsenic species separation was performed through the employ of a serial connection of membrane filters and

  14. Monitoring cell line identity in collections of human induced pluripotent stem cells

    Directory of Open Access Journals (Sweden)

    Raquel Sarafian

    2018-04-01

    Full Text Available The ability to reprogram somatic cells into induced pluripotent stem cells (hiPSCs has led to the generation of large collections of cell lines from thousands of individuals with specific phenotypes, many of which will be shared among different research groups as invaluable tools for biomedical research. As hiPSC-based research involves extensive culture of many cell lines, the issue periodic cell line identification is particularly important to ensure that cell line identity remains accurate. Here we analyzed the different commercially available genotyping methods considering ease of in-house genotyping, cost and informativeness, and applied one of them in our workflow for hiPSC generation. We show that the chosen STR method was able to establish a unique DNA profile for each of the 35 individuals/hiPSC lines at the examined sites, as well as identify two discrepancies resulting from inadvertently exchanged samples. Our results highlight the importance of hiPSC line genotyping by an in-house method that allows periodic cell line identification and demonstrate that STR is a useful approach to supplement less frequent karyotyping and epigenetic evaluations. Keywords: Induced pluripotent stem cells, Genotyping, Cell line identification, Short tandem repeats, Quality control

  15. A Comparative Study of Blood Culture Sampling from Umbilical Catheter Line versus Peripheral Site

    Directory of Open Access Journals (Sweden)

    Abdolkarim Hamedi

    2010-08-01

    Full Text Available Neonatal sepsis is an important cause of death and morbidity in newborns and is diagnosed by isolation of organism in blood culture. In several reports,reliablity of blood cultures were done from umbi lical catheters,have been demonstrated. The objective of the present study was to determine,wether an inde welling umbilical catheter, could be an alternative site for blood culture. In a prospective study over 6 months during 2006,141 paired blood cultures from 134 infant,were done simultaneously from peripheral site and umbilical catheter (mostly U. V. C,during the first four days of life. Majority of these infants were preterm and admitted to NICU for special care. these infants had indwelling umbilical line and had indication of sepsis workup. A total of 141 pairs of blood cultures were obtained from 134 infants. In 16 infants blood culture pairs were positive for one organism in both peripheral vein and umbilical site. 71. 6% of total cultures (n=11pairs were negative in boths site. A total of 22 pairs were positive in one site only,with 5 positive from peripheral vein only and the other 17 from umblical site. Two pairs were positve in boths site with two different organism. In over all 16 infant (11%of blood were considered to be contaminated. Contamination rate were 2. 4% and 9. 2% for peripheral and umbilical catheter site. Contamination rate increased after 48 hours of age in umbilical catheter. The result showed that after 2 days contamination rate for blood culture taken from catheter line increased and specifity decreased. We recommended that blood culture via umblical catheter in first 2 days in sick neonates with indwelling catheter can be a alternate site of blood culture sampelling.

  16. On-Line Ion Exchange Liquid Chromatography as a Process Analytical Technology for Monoclonal Antibody Characterization in Continuous Bioprocessing.

    Science.gov (United States)

    Patel, Bhumit A; Pinto, Nuno D S; Gospodarek, Adrian; Kilgore, Bruce; Goswami, Kudrat; Napoli, William N; Desai, Jayesh; Heo, Jun H; Panzera, Dominick; Pollard, David; Richardson, Daisy; Brower, Mark; Richardson, Douglas D

    2017-11-07

    Combining process analytical technology (PAT) with continuous production provides a powerful tool to observe and control monoclonal antibody (mAb) fermentation and purification processes. This work demonstrates on-line liquid chromatography (on-line LC) as a PAT tool for monitoring a continuous biologics process and forced degradation studies. Specifically, this work focused on ion exchange chromatography (IEX), which is a critical separation technique to detect charge variants. Product-related impurities, including charge variants, that impact function are classified as critical quality attributes (CQAs). First, we confirmed no significant differences were observed in the charge heterogeneity profile of a mAb through both at-line and on-line sampling and that the on-line method has the ability to rapidly detect changes in protein quality over time. The robustness and versatility of the PAT methods were tested by sampling from two purification locations in a continuous mAb process. The PAT IEX methods used with on-line LC were a weak cation exchange (WCX) separation and a newly developed shorter strong cation exchange (SCX) assay. Both methods provided similar results with the distribution of percent acidic, main, and basic species remaining unchanged over a 2 week period. Second, a forced degradation study showed an increase in acidic species and a decrease in basic species when sampled on-line over 7 days. These applications further strengthen the use of on-line LC to monitor CQAs of a mAb continuously with various PAT IEX analytical methods. Implementation of on-line IEX will enable faster decision making during process development and could potentially be applied to control in biomanufacturing.

  17. Measurements of visible forbidden lines and ion distributions of tungsten highly charged ions at the LHD

    International Nuclear Information System (INIS)

    Kato, D.; Sakaue, H.A.; Murakami, I.; Goto, M.; Morita, S.; Nakamura, N.; Koike, F.; Sasaki, Akira; Ding, X.-B.; Dong, C.-Z.

    2013-01-01

    Visible lines, which are presumably associated with forbidden lines from tungsten highly charged ions, were clearly observed in a spectrum of 370 - 410 nm recorded shortly after a tungsten pellet injection at the LHD. One of the measured lines has been assigned to a magnetic-dipole (M1) line of the ground-term fine-structure transition of W 26+ . Photon emission was observed at 44 lines of sight divided along the vertical direction of a horizontally elongated poloidal cross section of the LHD plasma. The line-integrated intensity of the lines along each line of sight indicates peaked profiles near the plasma center, while visible line emissions of neutral hydrogen and helium recoded in the same sampling time have a maximum located in the peripheral region of the poloidal cross section. (author)

  18. NARROW-LINE X-RAY-SELECTED GALAXIES IN THE CHANDRA -COSMOS FIELD. I. OPTICAL SPECTROSCOPIC CATALOG

    Energy Technology Data Exchange (ETDEWEB)

    Pons, E.; Watson, M. G. [University of Leicester, Leicester (United Kingdom); Elvis, M.; Civano, F. [Harvard-Smithsonian Center for Astrophysics, Cambridge, MA (United States)

    2016-04-20

    The COSMOS survey is a large and deep survey with multiwavelength observations of sources from X-rays to the UV, allowing an extensive study of their properties. The central 0.9 deg{sup 2} of the COSMOS field have been observed by Chandra with a sensitivity up to 1.9 × 10{sup −16} erg cm{sup −2} s{sup −1} in the full (0.5–10 keV) band. Photometric and spectroscopic identification of the Chandra -COSMOS (C-COSMOS) sources is available from several catalogs and campaigns. Despite the fact that the C-COSMOS galaxies have a reliable spectroscopic redshift in addition to a spectroscopic classification, the emission-line properties of this sample have not yet been measured. We present here the creation of an emission-line catalog of 453 narrow-line sources from the C-COSMOS spectroscopic sample. We have performed spectral fitting for the more common lines in galaxies ([O ii] λ 3727, [Ne iii] λ 3869, H β , [O iii] λλ 4959, 5007, H α , and [N ii] λλ 6548, 6584). These data provide an optical classification for 151 (i.e., 33%) of the C-COSMOS narrow-line galaxies based on emission-line diagnostic diagrams.

  19. Nicotine Contamination in Particulate Matter Sampling

    Directory of Open Access Journals (Sweden)

    Eric Garshick

    2009-02-01

    Full Text Available We have addressed potential contamination of PM2.5 filter samples by nicotine from cigarette smoke. We collected two nicotine samples – one nicotine sampling filter was placed in-line after the collection of PM2.5 and the other stood alone. The overall correlation between the two nicotine filter levels was 0.99. The nicotine collected on the “stand-alone” filter was slightly greater than that on the “in-line” filter (mean difference = 1.10 μg/m3, but the difference was statistically significant only when PM2.5 was low (≤ 50 μg/m3. It is therefore important to account for personal and secondhand smoke exposure while assessing occupational and environmental PM.

  20. Unmanned Aerial Vehicle Non Line of Sight Chemical Detection Final Report

    Science.gov (United States)

    2016-12-01

    aircraft system that is used to perform point detection of chemical warfare agents and collection of vapor, liquid, and solid samples. A modular payload...their goals to better protect the Warfighter. The North Atlantic Treaty Organization members have divided detection distances into the following three...materials for onboard analysis or transporting chemical samples for analysis to a mobile laboratory. An innovative proposed solution to non-line-of

  1. Differences between the genomes of lymphoblastoid cell lines and blood-derived samples

    Directory of Open Access Journals (Sweden)

    Joesch-Cohen LM

    2017-02-01

    Full Text Available Lena M Joesch-Cohen, Gustavo Glusman Institute for Systems Biology, Seattle, WA, USA Abstract: Lymphoblastoid cell lines (LCLs represent a convenient research tool for expanding the amount of biologic material available from an individual. LCLs are commonly used as reference materials, most notably from the Genome in a Bottle Consortium. However, the question remains how faithfully LCL-derived genome assemblies represent the germline genome of the donor individual as compared to the genome assemblies derived from peripheral blood mononuclear cells. We present an in-depth comparison of a large collection of LCL- and peripheral blood mononuclear cell-derived genomes in terms of distributions of coverage and copy number alterations. We found significant differences in the depth of coverage and copy number calls, which may be driven by differential replication timing. Importantly, these copy number changes preferentially affect regions closer to genes and with higher GC content. This suggests that genomic studies based on LCLs may display locus-specific biases, and that conclusions based on analysis of depth of coverage and copy number variation may require further scrutiny. Keywords: genomics, whole-genome sequencing, viral transformation, copy number changes, bioinformatics

  2. A study of parallelism of the occlusal plane and ala-tragus line.

    Science.gov (United States)

    Sadr, Katayoun; Sadr, Makan

    2009-01-01

    Orientation of the occlusal plane is one of the most important clinical procedures in prostho-dontic rehabilitation of edentulous patients. The aim of this study was to define the best posterior reference point of ala-tragus line for orientation of occlusal plane for complete denture fabrication. Fifty-three dental students (27 females and 26 males) with complete natural dentition and Angel's Class I occlusal relationship were selected. The subjects were photographed in natural head position while clenching on a Fox plane. After tracing the photographs, the angles between the following lines were measured: the occlusal plane (Fox plane) and the superior border of ala-tragus, the occlusal plane (Fox plane) and the middle of ala-tragus as well as the occlusal plane (Fox plane) and the inferior border of ala-tragus. Descriptive statistics, one sample t-test and independent t-test were used. P value less than 0.05 was considered significant. There was no parallelism between the occlusal plane and ala-tragus line with three different posterior ends and one sample t-test showed that the angles between them were significantly different from zero (pplane. The superior border of the tragus is suggested as the posterior reference for ala-tragus line.

  3. Isotopic meteoric line for Colombia

    International Nuclear Information System (INIS)

    Rodriguez N, Cesar O

    2004-01-01

    Isotope analyses from representative rainfall samples taken from different areas in Colombia were processed to yield the meteoric line. Stable isotope composition in precipitation reflects the effects of temperature, altitude and of the continental site, being affected by different sources of atmospheric humidity over the Colombian territory. There is a seasonal variation in isotopic composition of precipitation with grater σ deviation during the rainy season and lower values in the dry season. In coastal areas the variation is smaller and is more pronounced than at continental stations. Correlation between altitude and isotope content led to equations, which indicate, on a regional level, a change in isotopic composition with altitude, of about 0.5 σ units per 200 m, for O 18 and 4 σ units per 200 m for H 2 . Such equations may be used to identify the original altitude of precipitation water, in hydrological surface and groundwater studies. Meteoric line and the concepts derived from the resulting equations presented in this paper may be applied to the interpretation of isotope analysis in future hydrological studies, particularly in areas without available data

  4. Peptidomic analysis of human cell lines

    Science.gov (United States)

    Gelman, Julia S.; Sironi, Juan; Castro, Leandro M.; Ferro, Emer S.; Fricker, Lloyd D.

    2011-01-01

    Peptides have been proposed to function in intracellular signaling within the cytosol. Although cytosolic peptides are considered to be highly unstable, a large number of peptides have been detected in mouse brain and other biological samples. In the present study, we evaluated the peptidome of three diverse cell lines: SH-SY5Y, MCF7, and HEK293 cells. A comparison of the peptidomes revealed considerable overlap in the identity of the peptides found in each cell line. The majority of the observed peptides are not derived from the most abundant or least stable proteins in the cell, and approximately half of the cellular peptides correspond to the N- or C- termini of the precursor proteins. Cleavage site analysis revealed a preference for hydrophobic residues in the P1 position. Quantitative peptidomic analysis indicated that the levels of most cellular peptides are not altered in response to elevated intracellular calcium, suggesting that calpain is not responsible for their production. The similarity of the peptidomes of the three cell lines and the lack of correlation with the predicted cellular degradome implies the selective formation or retention of these peptides, consistent with the hypothesis that they are functional in the cells. PMID:21204522

  5. Industrial variographic analysis for continuous sampling system validation

    DEFF Research Database (Denmark)

    Engström, Karin; Esbensen, Kim Harry

    2017-01-01

    Karin Engström, LKAB mining, Kiruna, Sweden, continues to present illuminative cases from process industry. Here she reveals more from her ongoing PhD project showing application of variographic characterisation for on-line continuous control of process sampling systems, including the one...

  6. Development of BPM/BLM DAQ System for KOMAC Beam Line

    Energy Technology Data Exchange (ETDEWEB)

    Song, Young-Gi; Kim, Jae-Ha; Yun, Sang-Pil; Kim, Han-Sung; Kwon, Hyeok-Jung; Cho, Yong-Sub [Korea Atomic Energy Research Institute, Gyeongju (Korea, Republic of)

    2016-10-15

    The proton beam is accelerated from 3 MeV to 100 MeV through 11 DTL tanks. The KOMAC installed 10 beam lines, 5 for 20-MeV beams and 5 for 100-MeV beams. The proton beam is transmitted to two target room. The KOMAC has been operating two beam lines, one for 20 MeV and one for 100 MeV. New beam line, RI beam line is under commissioning. A Data Acquisition (DAQ) system is essential to monitor beam signals in an analog front-end circuitry from BPM and BLM at beam lines. A data acquisition (DAQ) system is essential to monitor beam signals in an analog front-end circuitry from BPM and BLM at beam lines. The DAQ digitizes beam signal and the sampling is synchronized with a reference signal which is an external trigger for beam operation. The digitized data is accessible by the Experimental Physics and Industrial Control System (EPICS)-based control system, which manages the whole accelerator control. The beam monitoring system integrates BLM and BPM signals into the control system and offers realtime data to operators. The IOC, which is implemented with Linux and a PCI driver, supports data acquisition as a very flexible solution.

  7. HB-Line Material Control and Accountability Measurements at SRS

    International Nuclear Information System (INIS)

    Casella, V.R.

    2003-01-01

    Presently, HB-Line work at the Savannah River Site consists primarily of the stabilization and packaging of nuclear materials for storage and the characterization of materials for disposition in H-Area. In order to ensure compliance with Material Control and Accountability (MC and A) Regulations, accountability measurements are performed throughout the HB-Line processes. Accountability measurements are used to keep track of the nuclear material inventory by constantly updating the amount of material in the MBAs (Material Balance Area) and sub-MBAs. This is done by subtracting the amount of accountable material that is added to a process and by adding the amount of accountable material that is put back in storage. A Physical Inventory is taken and compared to the ''Book Value'' listed in the Nuclear Material Accounting System. The difference (BPID) in the Book Inventory minus the Physical Inventory of a sub-account for bulk material must agree within the measurement errors combined in quadrature to provide assurance that nuclear material is accounted for. This work provides an overview of HB-Line processes and accountability measurements. The Scrap Recovery Line and Neptunium-237/Plutonium-239 Oxide Line are described and sampling and analyses for Phase II are provided. Recommendations for improvements are provided to improve efficiency and cost effectiveness

  8. Sampling and analysis methods for geothermal fluids and gases

    Energy Technology Data Exchange (ETDEWEB)

    Watson, J.C.

    1978-07-01

    The sampling procedures for geothermal fluids and gases include: sampling hot springs, fumaroles, etc.; sampling condensed brine and entrained gases; sampling steam-lines; low pressure separator systems; high pressure separator systems; two-phase sampling; downhole samplers; and miscellaneous methods. The recommended analytical methods compiled here cover physical properties, dissolved solids, and dissolved and entrained gases. The sequences of methods listed for each parameter are: wet chemical, gravimetric, colorimetric, electrode, atomic absorption, flame emission, x-ray fluorescence, inductively coupled plasma-atomic emission spectroscopy, ion exchange chromatography, spark source mass spectrometry, neutron activation analysis, and emission spectrometry. Material on correction of brine component concentrations for steam loss during flashing is presented. (MHR)

  9. Microextraction sample preparation techniques in biomedical analysis.

    Science.gov (United States)

    Szultka, Malgorzata; Pomastowski, Pawel; Railean-Plugaru, Viorica; Buszewski, Boguslaw

    2014-11-01

    Biologically active compounds are found in biological samples at relatively low concentration levels. The sample preparation of target compounds from biological, pharmaceutical, environmental, and food matrices is one of the most time-consuming steps in the analytical procedure. The microextraction techniques are dominant. Metabolomic studies also require application of proper analytical technique for the determination of endogenic metabolites present in biological matrix on trace concentration levels. Due to the reproducibility of data, precision, relatively low cost of the appropriate analysis, simplicity of the determination, and the possibility of direct combination of those techniques with other methods (combination types on-line and off-line), they have become the most widespread in routine determinations. Additionally, sample pretreatment procedures have to be more selective, cheap, quick, and environmentally friendly. This review summarizes the current achievements and applications of microextraction techniques. The main aim is to deal with the utilization of different types of sorbents for microextraction and emphasize the use of new synthesized sorbents as well as to bring together studies concerning the systematic approach to method development. This review is dedicated to the description of microextraction techniques and their application in biomedical analysis. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Minimizing new tritium line sensitivity by a quality process implemented at Madagascar-INSTN

    International Nuclear Information System (INIS)

    Rajaobelison, J.; Raoelina Andriambololona; Ramaroson, V.; Andriamiharitsoa, G.; Fareze, L.P.; Razafintsalama, F.F.A.; Marah, H.

    2009-01-01

    A quality process rigorously implemented in the Isotope Hydrology Laboratory of Madagascar-I.N.S.T.N has significantly contributed to minimize the sensitivity of a recently installed tritium line used for groundwater dating. The ISO/CEI 17025 standard has been applied to fifteen (15) groundwater samples collected from different boreholes in the semi-arid South of Madagascar. The results are in agreement with the spikes analyses results which show that the mean value of the enrichment factor is 23.78 and the enrichment parameter is 0.88 for a preliminary test. Such values are much higher than the usual ones (approximately of 18) for a first enrichment, indicating electrolytic cells optimised work. In addition, the standard deviations are respectively 1.6 and 0.02 for the enrichment factor and parameter, meaning therefore that the cells performances are relatively good. In addition, background measurement was carried out on a dead water sample and produced a relatively low value of 1.07cpm, them simultaneous activities measurement of indoor and outdoor control water samples gave approximately the same values. The latter results prove that there is no indoor contamination of the samples. Finally, the groundwater samples analysis results show that the water activities vary from 0.27 TU to 2.97 TU confirming that the tritium line sensitivity is lower than 0.30 TU and that the system is able to determine groundwater ages up to one thousand years (1000 a), whereas usual tritium lines sensitivities are around 0.80 TU.

  11. Laboratory techniques for safe encapsulation of α-emitting powder samples

    International Nuclear Information System (INIS)

    Chamberlain, H.E.; Pottinger, J.S.

    1984-01-01

    Plutonium oxide powder samples can be encapsulated in thin plastic film to prevent spread of contamination in counting and X-ray diffraction equipment. The film has to be thin enough to transmit X-rays and α-particles. Techniques are described for the wrapping process and the precautions necessary to keep the sample processing line free of significant contamination. (author)

  12. Spectroscopic and polarimetric study of radio-quiet weak emission line quasars

    Science.gov (United States)

    Kumar, Parveen; Chand, Hum; Gopal-Krishna; Srianand, Raghunathan; Stalin, Chelliah Subramonian; Petitjean, Patrick

    2018-04-01

    A small subset of optically selected radio-quiet QSOs with weak or no emission lines may turn out to be the elusive radio-quiet BL Lac objects, or simply be radio-quiet QSOs with an infant/shielded broad line region (BLR). High polarisation (p > 3-4%), a hallmark of BL Lacs, can be used to test whether some optically selected ‘radio-quiet weak emission line QSOs’ (RQWLQs) show a fractional polarisation high enough to qualify as radio-quiet analogues of BL Lac objects. To check this possibility, we have made optical spectral and polarisation measurements of a sample of 19 RQWLQs. Out of these, only 9 sources show a non-significant proper motion (hence very likely extragalactic) and only two of them are found to have p > 1%. For these two RQWLQs, namely J142505.59+035336.2 and J154515.77+003235.2, we found the highest polarization to be 1.59±0.53%, which is again too low to classify them as (radio-quiet) BL Lacs, although one may recall that even genuine BL Lacs sometimes appear weakly polarised. We also present a statistical comparison of the optical spectral index, for a sample of 45 RQWLQs with redshift-luminosity matched control samples of 900 QSOs and an equivalent sample of 120 blazars, assembled from the literature. The spectral index distribution of RQWLQs is found to differ, at a high significance level, from that of blazars. This, too, is consistent with the common view that the mechanism of the central engine in RQWLQs, as a population, is close to that operating in normal QSOs and the primary difference between them is related to the BLR.

  13. Bacterial contamination of groundwater in urban area of Karachi

    International Nuclear Information System (INIS)

    Zubair, A.; Rippey, B.

    1999-01-01

    Well-water samples (in=193) were collected from urban areas of five districts of Karachi during the period 1993 to 1995 to evaluate its bacteriological quality and their impact on city environment and morbidity patterns of inhabitants. Samples were analyzed by the standard method American Public Health Association. The bacteriological contamination level suggest that the groundwater of Chaahi is mainly affected by contamination of wastewater containing high levels of coliform and faecal coliform bacteria. This study points towards serious need to control the seepage from sewerage system and use of contaminated well-water should be discouraged to reduce the incidence of water-borne diseases in order to improve the quality of life and health. (author)

  14. THE PHOTOMETRIC AND KINEMATIC STRUCTURE OF FACE-ON DISK GALAXIES. II. INTEGRATED LINE PROFILE CHARACTERIZATION AND THE ORIGIN OF LINE PROFILE ASYMMETRY

    International Nuclear Information System (INIS)

    Andersen, David R.; Bershady, Matthew A.

    2009-01-01

    We perform a moments analysis of H I and H II global line profiles for 33 nearly face-on disk galaxies for the threefold purpose of rationalizing and interpreting line profile indices in the literature, presenting robust moment definitions with analytic error functions calibrated against Monte Carlo simulation, and probing the physical origin of line profile asymmetries. The first four profile moments serve as viable surrogates for the recession velocity, line width, asymmetry, and profile shape, respectively. The first three moments are superior, by a factor of ∼2 in precision, to related quantities defined in the literature. First and third profile moments are related; skew can be used to calculate more accurate recession velocities from global profiles. Second and fourth profile moments are linked, corresponding to the known trend that narrow (but well resolved) line widths tend to be more Gaussian. Hα kurtosis also appears correlated with the spatially resolved line width of the ionized gas. No systematics appear between various measures of line width and true rotation speed other than the wide range of normalizations, which we calibrate. This conclusion and calibration, however, is highly sample dependent. The ratio of H II to H I widths is consistent with unity, even at low projected line width. There may be a trend toward a decrease in the ratio of H II to H I widths consistent with previous studies, but we also observe greater scatter. While there is good agreement between H I and H II first, second, and fourth moments, we find no positive correlation between skew measured from H I and H II profiles. Detailed analysis of the spatially resolved Hα distribution demonstrates that H II global profile asymmetries are dominated by differences in the gas distribution, not kinematic asymmetries.

  15. LINE-1 hypomethylation in cancer is highly variable and inversely correlated with microsatellite instability.

    Directory of Open Access Journals (Sweden)

    Marcos R H Estécio

    2007-05-01

    Full Text Available Alterations in DNA methylation in cancer include global hypomethylation and gene-specific hypermethylation. It is not clear whether these two epigenetic errors are mechanistically linked or occur independently. This study was performed to determine the relationship between DNA hypomethylation, hypermethylation and microsatellite instability in cancer.We examined 61 cancer cell lines and 60 colorectal carcinomas and their adjacent tissues using LINE-1 bisulfite-PCR as a surrogate for global demethylation. Colorectal carcinomas with sporadic microsatellite instability (MSI, most of which are due to a CpG island methylation phenotype (CIMP and associated MLH1 promoter methylation, showed in average no difference in LINE-1 methylation between normal adjacent and cancer tissues. Interestingly, some tumor samples in this group showed increase in LINE-1 methylation. In contrast, MSI-showed a significant decrease in LINE-1 methylation between normal adjacent and cancer tissues (P<0.001. Microarray analysis of repetitive element methylation confirmed this observation and showed a high degree of variability in hypomethylation between samples. Additionally, unsupervised hierarchical clustering identified a group of highly hypomethylated tumors, composed mostly of tumors without microsatellite instability. We extended LINE-1 analysis to cancer cell lines from different tissues and found that 50/61 were hypomethylated compared to peripheral blood lymphocytes and normal colon mucosa. Interestingly, these cancer cell lines also exhibited a large variation in demethylation, which was tissue-specific and thus unlikely to be resultant from a stochastic process.Global hypomethylation is partially reversed in cancers with microsatellite instability and also shows high variability in cancer, which may reflect alternative progression pathways in cancer.

  16. Physico-chemical changes in grains of some advance lines/ varieties of rice (oryza sativa l.) after parboiling

    International Nuclear Information System (INIS)

    Akhter, M.; Haider, Z.

    2014-01-01

    Some of the advance lines/varieties developed at Rice Research Institute, Kala Shah Kaku, including approved fragrant (Basmati) rice variety i.e., Basmati-2000, were used to assess interactive efficacy of parboiling on these varieties/lines and practical expediency of using standardized parboiling technique for improving nutritional, milling and cooking qualities of these lines/varieties. For this purpose, white milled and parboiled rice samples of ten lines/varieties were analyzed for nutritional quality parameters such as ash, dry matter, crude fat, crude protein, crude fiber, vitamin B6; milling quality parameters such as total milling recovery, head rice recovery, ratio of broken grains and cooking quality parameters such as curling, bursting and cooked grain length. The study showed significant variation in efficacy of parboiling to different varieties/lines. The results clearly showed average increase in mineral contents in terms of ash% increase, dry matter, longer cooked grain length and considerable rise in vitamin B6 contents, higher total milling recovery and head rice recovery in almost all the samples. While crude fiber, crude protein and crude fat decreased non-significantly. Furthermore, quality reducing factors such as number of broken grains, bursting and curling percentage of cooked rice were also reduced significantly in parboiled samples. It may, therefore, be suggested that parboiling offers a better alternative to conserve and increase nutritional, milling and cooking quality values of rice varieties/lines. Less percentage of broken, burst and curled grains may result in augmented net income. (author)

  17. Extracellular enzyme activities of aquatic bacteria in polluted environment: 2. Amylolytic activity

    International Nuclear Information System (INIS)

    Arbaciauskiene, V.

    2003-01-01

    Water samples were taken from Lake Drukshiai tributaries (Ricanka); Gulbinele Stream affected by urban rain sewerage from Visaginas; Gulbinele Stream into which municipal sewage from Visaginas (MS) and industrial rain sewerage from the Ignalina NPP and their mouth, and Lake Dringis. Lake Dringis, in Aukstaitija National Park, was selected as an ecosystem pattern of a weak anthropogenic influence, while Lake Drukshiai was chosen as a regularly polluted water body. Lake Drukshiai, the cooling basin of the Ignalina NPP (IRS-1.2), is being polluted with industrial and municipal sewage through its tributaries. The amylolytic activity (AA) of heterotrophic aquatic bacteria was tested. The highest total mean AA of aquatic bacteria was calculated in Lake Dringis. Here, the results were significantly higher than in Lake Drukshiai tributaries and their mouths, excepting the mouths of the Ricanka and MS. The lowest mean of AA in Lake Drukshiai was characteristic of the IRS-1.2 tributary. A comparison of the mean AA of active isolates showed that certain bacterial strains from the sites of varying degrees of pollution could be noted for a relatively high level of enzymatic activity. Thus, anthropogenic pollution exerts a negative effect on the total mean AA, although certain strains of bacteria are able to adapt to the stressful environment and remain active. (author)

  18. On-line coupled LC-LC-GC for irradiation detection in complex lipid matrices

    International Nuclear Information System (INIS)

    Schulzki, G.; Spiegelberg, A.; Helle, N.; Boegl, K.W.; Schreiber, G.A.

    1993-01-01

    Since sample preparation with HPLC coupled on-line to the GC has been performed for only a few weeks in our laboratory, the results presented give a first look at what can be done by means of this technique. Even difficult samples as the described fish species, where an unequivocal identification regarding an irradiation treatment seemed to become a hopeless enterprise, could be managed. Because of the greater variety of fatty acids in fish ''new'' radiation-induced hydrocarbons were available. According to the theory of Nawar in addition to 16:2 and 17:2 hydrocarbons we have looked for in irradiated meat, further alkadienes appeared in irradiated fish, which were 14:2, 18:2 and 20:2. Analysis of the alkadiene-fraction, transferred to the GC after a two step LC clean up, resulted in an unequivocal identification of all fish samples as well as the fruits and sponge cake. For fruits and sponge cake the detection limit seems to be clearly below 0.5 kGy. It can further be lowered by increasing the amount of lipid whereas the upper limit for a certain LC column has to be determined. In contrast to these samples only qualitative results were obtained for fish. In the case of sponge cake for the first time irradiation of a component of a heat treated food was detected. Further investigations regarding reproducibility, dose dependence and detection limit have to be done. On-line coupled (LC-)LC-GC was proved to be a highly efficient method for analysis of complex samples. In contrast to off-line Florisil column chromatography only a small part of the initial lipid material is needed because the complete hydrocarbon fraction is transferred on-line to the GC. This offers the possibility to analyze even foods with a low fat content like various seafoods. Classification of the hydrocarbon fraction by a two step LC may facilitate the identification of the radiolytic products also if no mass spectrometric detection system is available. (orig./vhe)

  19. Line width measurement below 60 nm using an optical interferometer and artificial neural network

    Science.gov (United States)

    See, Chung W.; Smith, Richard J.; Somekh, Michael G.; Yacoot, Andrew

    2007-03-01

    We have recently described a technique for optical line-width measurements. The system currently is capable of measuring line-width down to 60 nm with a precision of 2 nm, and potentially should be able to measure down to 10nm. The system consists of an ultra-stable interferometer and artificial neural networks (ANNs). The former is used to generate optical profiles which are input to the ANNs. The outputs of the ANNs are the desired sample parameters. Different types of samples have been tested with equally impressive results. In this paper we will discuss the factors that are essential to extend the application of the technique. Two of the factors are signal conditioning and sample classification. Methods, including principal component analysis, that are capable of performing these tasks will be considered.

  20. Clustering Properties of Emission Line Selected Galaxies over the past 12.5 Gyrs

    Science.gov (United States)

    Khostovan, Ali Ahmad; Sobral, David; Mobasher, Bahram; Best, Philip N.; Smail, Ian; Matthee, Jorryt; Darvish, Behnam; Nayyeri, Hooshang; Hemmati, Shoubaneh; Stott, John P.

    2018-01-01

    In this talk, I will present my latest results on the clustering and dark matter halo (DMH) mass properties of ~7000 narrowband-selected [OIII] and [OII] emitters. I will briefly describe the past work that has been done with our samples (e.g., luminosity functions, evolution of equivalent widths) as motivation of using [OIII] and [OII] emitters to study clustering/halo properties. My talk will focus on our findings regarding the line luminosity and stellar mass dependencies with DMH mass. We find strongly increasing and redshift-independent trends between line luminosity and DMH mass with evidence for a shallower slope at the bright end consistent with halo masses of ~ 1012.5-13 M⊙. Similar, but weaker, trends between stellar mass and halo mass have also been found. We investigate the inter-dependencies of these trends on halo mass and find that the correlation with line luminosity is stronger than with stellar mass. This suggest that active galaxies may be connected with their host DMHs simply based on their emission line luminosity. If time permits, I will briefly present our most recent results using our sample of ~4000 Lyα emitters, where we find similar trends to that seen with the [OIII] and [OII] samples, as well as previous Hα measurements, which suggests galaxies selected based on emission lines may be tracing the same subpopulation of star forming galaxies. I will conclude my talk with an interpretation of this connection and suggest that the shallower slope seen for the brightest emitters is evidence for a transitional halo mass as suggested in models where quenching mechanisms truncate star formation activity and reduce the fraction of star forming galaxies with increasing halo mass.

  1. The Wilson-Bappu effect of the MgII k line - dependence on stellar temperature, activity and metallicity

    DEFF Research Database (Denmark)

    Elgaroy, O.; Engvold, O.; Lund, Niels

    1999-01-01

    widths around the regression lines. The sample contains slowly rotating stars of different activity levels and is suitable for investigations of a possible relation between line width and stellar activity. A difference in behavior between dwarfs and giants (and supergiants) of spectral class K seems......The Wilson-Bappu effect is investigated using accurate absolute magnitudes of 65 stars obtained through early release of data from the Hipparcos satellite together with MgII k fine widths determined from high resolution spectra observed with the International Ultraviolet Explorer (IUE) observatory....... Stars of spectral classes F, G, K and M and luminosity classes I-V are represented in the sample. Wilson-Bappu relations for the Mg II k line for stars of different temperatures i.e. spectral classes are determined. The relation varies with spectral class and there is a significant scatter of the line...

  2. REQUIREMENTS AND GUIDELINES FOR NSLS EXPERIMENTAL BEAM LINE VACUUM SYSTEMS-REVISION B

    International Nuclear Information System (INIS)

    FOERSTER, C.

    1999-01-01

    Typical beam lines are comprised of an assembly of vacuum valves and shutters referred to as a ''front end'', optical elements to monochromatize, focus and split the photon beam, and an experimental area where a target sample is placed into the photon beam and data from the interaction is detected and recorded. Windows are used to separate sections of beam lines that are not compatible with storage ring ultra high vacuum. Some experimental beam lines share a common vacuum with storage rings. Sections of beam lines are only allowed to vent up to atmospheric pressure using pure nitrogen gas after a vacuum barrier is established to protect ring vacuum. The front end may only be bled up when there is no current in the machine. This is especially true on the VUV storage ring where for most experiments, windows are not used. For the shorter wavelength, more energetic photons of the x-ray ring, beryllium windows are used at various beam line locations so that the monochromator, mirror box or sample chamber may be used in a helium atmosphere or rough vacuum. The window separates ring vacuum from the environment of the downstream beam line components. The stored beam lifetime in the storage rings and the maintenance of desirable reflection properties of optical surfaces depend upon hydrocarbon-free, ultra-high vacuum systems. Storage ring vacuum systems will operate at pressures of ∼ 1 x 10 -10 Torr without beam and ∼ 1 x 10 -9 Torr with beam. Systems are free of hydrocarbons in the sense that no pumps, valves, etc. containing organics are used. Components are all-metal, chemically cleaned and bakeable. To the extent that beam lines share a common vacuum with the storage ring, the same criteria will hold for beam line components. The design philosophy for NSLS beam lines is to use all-metal, hydrocarbon-free front end components and recommend that experimenters use this approach for common vacuum hardware downstream of front ends. O-ring-sealed valves, if used, are not

  3. Measurement of trace levels of antibiotics in river water using on-line enrichment and triple-quadrupole LC-MS/MS.

    Science.gov (United States)

    Dinh, Quoc Tuc; Alliot, Fabrice; Moreau-Guigon, Elodie; Eurin, Joëlle; Chevreuil, Marc; Labadie, Pierre

    2011-09-15

    This study presents the development of an automated on-line solid phase extraction (SPE)-liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of 23 antibiotics in environmental water samples. After optimisation of LC-MS/MS conditions, SPE parameters such as sorbent type, sample pH or sample volume were optimised. Antibiotic recoveries ranged from 64% to 98% and compared favourably with those achieved using off-line SPE. Limits of detection were in the range 0.5-13.7 ng L(-1). This on-line SPE-LC-MS/MS procedure was applied to the analysis of water samples taken in three rivers within the Seine River basin, near Paris (France). The obtained results revealed the occurrence of 12 antibiotics, including tylosin, erythromycin, tetracycline, amoxicillin, trimethoprim, sulfamethoxazole, oxolinic acid, flumequine, norfloxacin, ciprofloxacin, ofloxacin, and vancomycin (2-1435 ng L(-1)). Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Simultaneous in-line concentration for spectrophotometric determination of cations and anions

    Directory of Open Access Journals (Sweden)

    Rocha Fábio R. P

    2004-01-01

    Full Text Available A flow system is proposed for simultaneous in-line concentration of cations and anions. A sliding-bar commutator was employed to insert an anion and a cation exchange column into a flowing sample stream for serial retention of the analytes. In the injector alternative position, different solutions flowed through the columns for parallel elution of the species in different analytical paths. Three-way solenoid valves allowed the intermittent reagent introduction in the sample zones. Signals were measured by employing two flow-through LED-based detectors. The simultaneous retention of the sample zones in coiled reactors can be also performed to increase the residence time and the analyte conversion rate. The analytical potentiality was demonstrated by the in-line concentration of ammonium and phosphate followed by spectrophotometric detection. For a 90 s loading time, the sampling rate was estimated as 40 determinations per hour, which is three-fold higher than the obtained without performing the tasks simultaneously. Enrichment factors of 8.0 and 18 were estimated for phosphate and ammonium, respectively, yielding detection limits of 1 mg L-1 PO4(3- and 1 mg L-1 NH4+ (99.7% confidence level. The reagent consumption was lower than 2 mg per determination. Results for freshwater samples agreed with the obtained by reference APHA procedures at the 95% confidence level.

  5. Preparing and measuring ultra-small radiocarbon samples with the ARTEMIS AMS facility in Saclay, France

    Energy Technology Data Exchange (ETDEWEB)

    Delque-Kolic, E., E-mail: emmanuelle.delque-kolic@cea.fr [LMC14, CEA Saclay, Batiment 450 Porte 4E, 91191 Gif sur Yvette (France); Comby-Zerbino, C.; Ferkane, S.; Moreau, C.; Dumoulin, J.P.; Caffy, I.; Souprayen, C.; Quiles, A.; Bavay, D.; Hain, S.; Setti, V. [LMC14, CEA Saclay, Batiment 450 Porte 4E, 91191 Gif sur Yvette (France)

    2013-01-15

    The ARTEMIS facility in Saclay France measures, on average, 4500 samples a year for French organizations working in an array of fields, including environmental sciences, archeology and hydrology. In response to an increasing demand for the isolation of specific soil compounds and organic water fractions, we were motivated to evaluate our ability to reduce microgram samples using our standard graphitization lines and to measure the graphite thus obtained with our 3MV NEC Pelletron AMS. Our reduction facility consists of two fully automated graphitization lines. Each line has 12 reduction reactors with a reduction volume of 18 ml for the first line and 12 ml for the second. Under routine conditions, we determined that we could reduce the samples down to 10 {mu}g of carbon, even if the graphitization yield is consequently affected by the lower sample mass. Our results when testing different Fe/C ratios suggest that an amount of 1.5 mg of Fe powder was ideal (instead of lower amounts of catalyst) to prevent the sample from deteriorating too quickly under the Cs+ beam, and to facilitate pressing procedures. Several sets of microsamples produced from HOxI standard, international references and backgrounds were measured. When measuring {sup 14}C-free wood charcoal and HOxI samples we determined that our modern and dead blanks, due to the various preparation steps, were of 1.1 {+-} 0.8 and 0.2 {+-} 0.1 {mu}g, respectively. The results presented here were obtained for IAEA-C1, {sup 14}C-free wood, IAEA-C6, IAEA-C2 and FIRI C.

  6. Preparing and measuring ultra-small radiocarbon samples with the ARTEMIS AMS facility in Saclay, France

    International Nuclear Information System (INIS)

    Delqué-Količ, E.; Comby-Zerbino, C.; Ferkane, S.; Moreau, C.; Dumoulin, J.P.; Caffy, I.; Souprayen, C.; Quilès, A.; Bavay, D.; Hain, S.; Setti, V.

    2013-01-01

    The ARTEMIS facility in Saclay France measures, on average, 4500 samples a year for French organizations working in an array of fields, including environmental sciences, archeology and hydrology. In response to an increasing demand for the isolation of specific soil compounds and organic water fractions, we were motivated to evaluate our ability to reduce microgram samples using our standard graphitization lines and to measure the graphite thus obtained with our 3MV NEC Pelletron AMS. Our reduction facility consists of two fully automated graphitization lines. Each line has 12 reduction reactors with a reduction volume of 18 ml for the first line and 12 ml for the second. Under routine conditions, we determined that we could reduce the samples down to 10 μg of carbon, even if the graphitization yield is consequently affected by the lower sample mass. Our results when testing different Fe/C ratios suggest that an amount of 1.5 mg of Fe powder was ideal (instead of lower amounts of catalyst) to prevent the sample from deteriorating too quickly under the Cs+ beam, and to facilitate pressing procedures. Several sets of microsamples produced from HOxI standard, international references and backgrounds were measured. When measuring 14 C-free wood charcoal and HOxI samples we determined that our modern and dead blanks, due to the various preparation steps, were of 1.1 ± 0.8 and 0.2 ± 0.1 μg, respectively. The results presented here were obtained for IAEA-C1, 14 C-free wood, IAEA-C6, IAEA-C2 and FIRI C.

  7. Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology

    DEFF Research Database (Denmark)

    Dumonceau, Jean-Marc; Deprez, Pierre H; Jenssen, Christian

    2017-01-01

    For pancreatic solid lesions, ESGE recommends performing endoscopic ultrasound (EUS)-guided sampling as first-line procedure when a pathological diagnosis is required. Alternatively, percutaneous sampling may be considered in metastatic disease.Strong recommendation, moderate quality evidence.In ...

  8. Elemental Abundances in the Broad Emission Line Region of Quasars at Redshifts larger than 4

    DEFF Research Database (Denmark)

    Dietrich, M.; Appenzeller, I.; Hamann, F.

    2003-01-01

    the chemical composition of the line emitting gas. Comparisons to photoionization calculations indicate gas metallicities in the broad emission line region in the range of solar to several times solar. The average of the mean metallicity of each high-z quasar in this sample is $Z/Z_\\odot = 4.3 \\pm 0...

  9. The Use of Energy Storage Systems for Supporting the Voltage Needs of Urban and Suburban Railway Contact Lines

    Directory of Open Access Journals (Sweden)

    Enrico Pagano

    2013-03-01

    Full Text Available The paper aims to contribute to the use of electric double layer capacitor (EDLC sets for boosting voltages of contact lines in urban and suburban railway traction systems. Different electrical configurations of contact lines are considered and investigated. For each of them, proper mathematical models are suggested to evaluate the electrical performances of the contact lines. They give rise, also, to sample design procedures for the sizing of the most appropriate energy storage systems, to be distributed along the lines, for boosting line voltages and avoiding undesired voltage drops. A numerical example based on the “Cumana” suburban Naples railway network is presented to give an idea of the weights and sizes of electric double layer capacitors needed to boost the voltage of a sample contact line. In particular, three different EDLC systems, for a overall installed energy of 9.6 kWh, have been placed nearby the stations presenting the highest voltage drops during the most representative situation of trains’ service. The new voltage drop is equal to 32% of that obtained in absence of EDLCs.

  10. The Use of Energy Storage Systems for Supporting the Voltage Needs of Urban and Suburban Railway Contact Lines

    Energy Technology Data Exchange (ETDEWEB)

    Iannuzzi, Diago [University of Federico II, Naples (Italy). Electrical Engineering Department; Pagano, Enrico [University of Federico II, Naples (Italy). Electrical Engineering Department; Tricoli, Pietro [University of Birmingham (United Kingdom). School of Electronic, Electrical and Computer Engineering

    2013-04-15

    The paper aims to contribute to the use of electric double layer capacitor (EDLC) sets for boosting voltages of contact lines in urban and suburban railway traction systems. Different electrical configurations of contact lines are considered and investigated. For each of them, proper mathematical models are suggested to evaluate the electrical performances of the contact lines. They give rise, also, to sample design procedures for the sizing of the most appropriate energy storage systems, to be distributed along the lines, for boosting line voltages and avoiding undesired voltage drops. A numerical example based on the “Cumana” suburban Naples railway network is presented to give an idea of the weights and sizes of electric double layer capacitors needed to boost the voltage of a sample contact line. In particular, three different EDLC systems, for a overall installed energy of 9.6 kWh, have been placed nearby the stations presenting the highest voltage drops during the most representative situation of trains’ service. The new voltage drop is equal to 32% of that obtained in absence of EDLCs.

  11. Transmission Line Ampacity Improvements of AltaLink Wind Plant Overhead Tie-Lines Using Weather-Based Dynamic Line Rating

    Energy Technology Data Exchange (ETDEWEB)

    Bhattarai, Bishnu P.; Gentle, Jake P.; Hill, Porter; McJunkin, Tim; Myers, Kurt S.; Abbound, Alex; Renwick, Rodger; Hengst, David

    2017-07-01

    Abstract—Overhead transmission lines (TLs) are conventionally given seasonal ratings based on conservative environmental assumptions. Such an approach often results in underutilization of the line ampacity as the worst conditions prevail only for a short period over a year/season. We presents dynamic line rating (DLR) as an enabling smart grid technology that adaptively computes ratings of TLs based on local weather conditions to utilize additional headroom of existing lines. In particular, general line ampacity state solver utilizes measured weather data for computing the real-time thermal rating of the TLs. The performance of the presented method is demonstrated from a field study of DLR technology implementation on four TL segments at AltaLink, Canada. The performance is evaluated and quantified by comparing the existing static and proposed dynamic line ratings, and the potential benefits of DLR for enhanced transmission assets utilization. For the given line segments, the proposed DLR results in real-time ratings above the seasonal static ratings for most of the time; up to 95.1% of the time, with a mean increase of 72% over static rating.

  12. The Joint Structural Biology Group beam lines at the ESRF: Modern macromolecular crystallography

    CERN Document Server

    Mitchell, E P

    2001-01-01

    Macromolecular crystallography has evolved considerably over the last decade. Data sets in under an hour are now possible on high throughput beam lines leading to electron density and, possibly, initial models calculated on-site. There are five beam lines currently dedicated to macromolecular crystallography: the ID14 complex and BM-14 (soon to be superseded by ID-29). These lines handle over five hundred projects every six months and demand is increasing. Automated sample handling, alignment and data management protocols will be required to work efficiently with this demanding load. Projects developing these themes are underway within the JSBG.

  13. POINT CLOUD ORIENTED SHOULDER LINE EXTRACTION IN LOESS HILLY AREA

    Directory of Open Access Journals (Sweden)

    L. Min

    2016-06-01

    Full Text Available Shoulder line is the significant line in hilly area of Loess Plateau in China, dividing the surface into positive and negative terrain (P-N terrains. Due to the point cloud vegetation removal methods of P-N terrains are different, there is an imperative need for shoulder line extraction. In this paper, we proposed an automatic shoulder line extraction method based on point cloud. The workflow is as below: (i ground points were selected by using a grid filter in order to remove most of noisy points. (ii Based on DEM interpolated by those ground points, slope was mapped and classified into two classes (P-N terrains, using Natural Break Classified method. (iii The common boundary between two slopes is extracted as shoulder line candidate. (iv Adjust the filter gird size and repeat step i-iii until the shoulder line candidate matches its real location. (v Generate shoulder line of the whole area. Test area locates in Madigou, Jingbian County of Shaanxi Province, China. A total of 600 million points are acquired in the test area of 0.23km2, using Riegl VZ400 3D Laser Scanner in August 2014. Due to the limit Granted computing performance, the test area is divided into 60 blocks and 13 of them around the shoulder line were selected for filter grid size optimizing. The experiment result shows that the optimal filter grid size varies in diverse sample area, and a power function relation exists between filter grid size and point density. The optimal grid size was determined by above relation and shoulder lines of 60 blocks were then extracted. Comparing with the manual interpretation results, the accuracy of the whole result reaches 85%. This method can be applied to shoulder line extraction in hilly area, which is crucial for point cloud denoising and high accuracy DEM generation.

  14. Point Cloud Oriented Shoulder Line Extraction in Loess Hilly Area

    Science.gov (United States)

    Min, Li; Xin, Yang; Liyang, Xiong

    2016-06-01

    Shoulder line is the significant line in hilly area of Loess Plateau in China, dividing the surface into positive and negative terrain (P-N terrains). Due to the point cloud vegetation removal methods of P-N terrains are different, there is an imperative need for shoulder line extraction. In this paper, we proposed an automatic shoulder line extraction method based on point cloud. The workflow is as below: (i) ground points were selected by using a grid filter in order to remove most of noisy points. (ii) Based on DEM interpolated by those ground points, slope was mapped and classified into two classes (P-N terrains), using Natural Break Classified method. (iii) The common boundary between two slopes is extracted as shoulder line candidate. (iv) Adjust the filter gird size and repeat step i-iii until the shoulder line candidate matches its real location. (v) Generate shoulder line of the whole area. Test area locates in Madigou, Jingbian County of Shaanxi Province, China. A total of 600 million points are acquired in the test area of 0.23km2, using Riegl VZ400 3D Laser Scanner in August 2014. Due to the limit Granted computing performance, the test area is divided into 60 blocks and 13 of them around the shoulder line were selected for filter grid size optimizing. The experiment result shows that the optimal filter grid size varies in diverse sample area, and a power function relation exists between filter grid size and point density. The optimal grid size was determined by above relation and shoulder lines of 60 blocks were then extracted. Comparing with the manual interpretation results, the accuracy of the whole result reaches 85%. This method can be applied to shoulder line extraction in hilly area, which is crucial for point cloud denoising and high accuracy DEM generation.

  15. Ultraviolet photometry from the orbiting astronomical observatory. XVI - The stellar Lyman-alpha absorption line

    Science.gov (United States)

    Savage, B. D.; Panek, R. J.

    1974-01-01

    The stellar Lyman-alpha line at 1216 A was observed in 29 lightly reddened stars of spectral type B2.5 to B9 by a far-UV spectrophotometer on OAO-2. The equivalent widths obtained range from 15 A at type B2.5 to 65 A at type B8; in the late-B stars, the L-alpha line removes 2 to 3% of the total stellar flux. In this sampling, the strength of the L-alpha line correlates well with measures of the Balmer discontinuity and Balmer line strengths; luminosity classification does not seem to affect the line strength. The observed line widths also agree with the predictions of Mihala's grid of non-LTE model atmospheres. In some cases, the L-alpha line influences the interstellar column densities reported in the interstellar OAO-2 L-alpha survey. Hence, these data toward lightly reddened B2 and B1.5 stars should be regarded as upper limits only.

  16. Using mark-recapture distance sampling methods on line transect surveys

    Science.gov (United States)

    Burt, Louise M.; Borchers, David L.; Jenkins, Kurt J.; Marques, Tigao A

    2014-01-01

    Mark–recapture distance sampling (MRDS) methods are widely used for density and abundance estimation when the conventional DS assumption of certain detection at distance zero fails, as they allow detection at distance zero to be estimated and incorporated into the overall probability of detection to better estimate density and abundance. However, incorporating MR data in DS models raises survey and analysis issues not present in conventional DS. Conversely, incorporating DS assumptions in MR models raises issues not present in conventional MR. As a result, being familiar with either conventional DS methods or conventional MR methods does not on its own put practitioners in good a position to apply MRDS methods appropriately. This study explains the sometimes subtly different varieties of MRDS survey methods and the associated concepts underlying MRDS models. This is done as far as possible without giving mathematical details – in the hope that this will make the key concepts underlying the methods accessible to a wider audience than if we were to present the concepts via equations.

  17. The U-tube sampling methodology and real-time analysis of geofluids

    International Nuclear Information System (INIS)

    Freifeld, Barry; Perkins, Ernie; Underschultz, James; Boreham, Chris

    2009-01-01

    The U-tube geochemical sampling methodology, an extension of the porous cup technique proposed by Wood (1973), provides minimally contaminated aliquots of multiphase fluids from deep reservoirs and allows for accurate determination of dissolved gas composition. The initial deployment of the U-tube during the Frio Brine Pilot CO 2 storage experiment, Liberty County, Texas, obtained representative samples of brine and supercritical CO 2 from a depth of 1.5 km. A quadrupole mass spectrometer provided real-time analysis of dissolved gas composition. Since the initial demonstration, the U-tube has been deployed for (1) sampling of fluids down gradient of the proposed Yucca Mountain High-Level Waste Repository, Armagosa Valley, Nevada (2) acquiring fluid samples beneath permafrost in Nunuvut Territory, Canada, and (3) at a CO 2 storage demonstration project within a depleted gas reservoir, Otway Basin, Victoria, Australia. The addition of in-line high-pressure pH and EC sensors allows for continuous monitoring of fluid during sample collection. Difficulties have arisen during U-tube sampling, such as blockage of sample lines from naturally occurring waxes or from freezing conditions; however, workarounds such as solvent flushing or heating have been used to address these problems. The U-tube methodology has proven to be robust, and with careful consideration of the constraints and limitations, can provide high quality geochemical samples.

  18. Directed line liquids

    International Nuclear Information System (INIS)

    Kamien, R.D.

    1992-01-01

    This thesis is devoted to the study of ensembles of dense directed lines. These lines are principally to be thought of as polymers, though they also have the morphology of flux lines in high temperature superconductors, strings of colloidal spheres in electrorheological fluids and the world lines of quantum mechanical bosons. The authors discuss how directed polymer melts, string-like formations in electrorheological and ferro-fluids, flux lines in high temperature superconductors and the world lines of quantum mechanical bosons all share similar descriptions. They study a continuous transition in all of these systems, and then study the critical mixing properties of binary mixtures of directed polymers through the renormalization group. They predict the exponents for a directed polymer blend consolute point and a novel two-phase superfluid liquid-gas critical point

  19. Size characterization of airborne SiO2 nanoparticles with on-line and off-line measurement techniques: an interlaboratory comparison study

    Science.gov (United States)

    Motzkus, C.; Macé, T.; Gaie-Levrel, F.; Ducourtieux, S.; Delvallee, A.; Dirscherl, K.; Hodoroaba, V.-D.; Popov, I.; Popov, O.; Kuselman, I.; Takahata, K.; Ehara, K.; Ausset, P.; Maillé, M.; Michielsen, N.; Bondiguel, S.; Gensdarmes, F.; Morawska, L.; Johnson, G. R.; Faghihi, E. M.; Kim, C. S.; Kim, Y. H.; Chu, M. C.; Guardado, J. A.; Salas, A.; Capannelli, G.; Costa, C.; Bostrom, T.; Jämting, Å. K.; Lawn, M. A.; Adlem, L.; Vaslin-Reimann, S.

    2013-10-01

    Results of an interlaboratory comparison on size characterization of SiO2 airborne nanoparticles using on-line and off-line measurement techniques are discussed. This study was performed in the framework of Technical Working Area (TWA) 34—"Properties of Nanoparticle Populations" of the Versailles Project on Advanced Materials and Standards (VAMAS) in the project no. 3 "Techniques for characterizing size distribution of airborne nanoparticles". Two types of nano-aerosols, consisting of (1) one population of nanoparticles with a mean diameter between 30.3 and 39.0 nm and (2) two populations of non-agglomerated nanoparticles with mean diameters between, respectively, 36.2-46.6 nm and 80.2-89.8 nm, were generated for characterization measurements. Scanning mobility particle size spectrometers (SMPS) were used for on-line measurements of size distributions of the produced nano-aerosols. Transmission electron microscopy, scanning electron microscopy, and atomic force microscopy were used as off-line measurement techniques for nanoparticles characterization. Samples were deposited on appropriate supports such as grids, filters, and mica plates by electrostatic precipitation and a filtration technique using SMPS controlled generation upstream. The results of the main size distribution parameters (mean and mode diameters), obtained from several laboratories, were compared based on metrological approaches including metrological traceability, calibration, and evaluation of the measurement uncertainty. Internationally harmonized measurement procedures for airborne SiO2 nanoparticles characterization are proposed.

  20. Size characterization of airborne SiO2 nanoparticles with on-line and off-line measurement techniques: an interlaboratory comparison study

    International Nuclear Information System (INIS)

    Motzkus, C.; Macé, T.; Gaie-Levrel, F.; Ducourtieux, S.; Delvallee, A.; Dirscherl, K.; Hodoroaba, V.-D.; Popov, I.; Popov, O.; Kuselman, I.; Takahata, K.; Ehara, K.; Ausset, P.; Maillé, M.; Michielsen, N.; Bondiguel, S.; Gensdarmes, F.; Morawska, L.; Johnson, G. R.; Faghihi, E. M.

    2013-01-01

    Results of an interlaboratory comparison on size characterization of SiO 2 airborne nanoparticles using on-line and off-line measurement techniques are discussed. This study was performed in the framework of Technical Working Area (TWA) 34—“Properties of Nanoparticle Populations” of the Versailles Project on Advanced Materials and Standards (VAMAS) in the project no. 3 “Techniques for characterizing size distribution of airborne nanoparticles”. Two types of nano-aerosols, consisting of (1) one population of nanoparticles with a mean diameter between 30.3 and 39.0 nm and (2) two populations of non-agglomerated nanoparticles with mean diameters between, respectively, 36.2–46.6 nm and 80.2–89.8 nm, were generated for characterization measurements. Scanning mobility particle size spectrometers (SMPS) were used for on-line measurements of size distributions of the produced nano-aerosols. Transmission electron microscopy, scanning electron microscopy, and atomic force microscopy were used as off-line measurement techniques for nanoparticles characterization. Samples were deposited on appropriate supports such as grids, filters, and mica plates by electrostatic precipitation and a filtration technique using SMPS controlled generation upstream. The results of the main size distribution parameters (mean and mode diameters), obtained from several laboratories, were compared based on metrological approaches including metrological traceability, calibration, and evaluation of the measurement uncertainty. Internationally harmonized measurement procedures for airborne SiO 2 nanoparticles characterization are proposed

  1. Photographs of quantized vortex lines in rotating superfluid helium

    International Nuclear Information System (INIS)

    Williams, G.A.

    1974-01-01

    The spatial positions of quantized vortex lines in rotating He II have been determined using a photographic technique. Electrons are trapped on the vortices and then extracted through the liquid surface and accelerated into a phosphor screen. The light from the phosphor is transmitted to room temperature with coherent fiber optics and photographed with an image intensifier camera. Photographs taken with pure 4 He at T = 0.3 K were complete blurs. These blurs are attributed to nonequilibrium motion of the vortices, arising from the lack of normal fluid damping at this temperature. To resolve the individual vortex lines it was found necessary to add 3 He to the 4 He sample to damp the vortex motion. Photographs are presented for 3 He concentrations up to 1.6 percent. The number of vortices visible varies linearly with rotation speed, but is only about one-half the number expected from theory. The vortex lines in the apparatus were not observed to form a stable array

  2. Line-scanning tomographic optical microscope with isotropic transfer function

    International Nuclear Information System (INIS)

    Gajdátsy, Gábor; Dudás, László; Erdélyi, Miklós; Szabó, Gábor

    2010-01-01

    An imaging method and optical system, referred to as a line-scanning tomographic optical microscope (LSTOM) using a combination of line-scanning technique and CT reconstruction principle, is proposed and studied theoretically and experimentally. In our implementation a narrow focus line is scanned over the sample and the reflected light is measured in a confocal arrangement. One such scan is equivalent to a transverse projection in tomography. Repeating the scanning procedure in several directions, a number of transverse projections are recorded from which the image can be obtained using conventional CT reconstruction algorithms. The resolution of the image is independent of the spatial dimensions and structure of the applied detector; furthermore, the transfer function of the system is isotropic. The imaging performance of the implemented confocal LSTOM was compared with a point-scanning confocal microscope, based on recorded images. These images demonstrate that the resolution of the confocal LSTOM exceeds (by 15%) the resolution limit of a point-scanning confocal microscope

  3. A Unimodal Model for Double Observer Distance Sampling Surveys.

    Directory of Open Access Journals (Sweden)

    Earl F Becker

    Full Text Available Distance sampling is a widely used method to estimate animal population size. Most distance sampling models utilize a monotonically decreasing detection function such as a half-normal. Recent advances in distance sampling modeling allow for the incorporation of covariates into the distance model, and the elimination of the assumption of perfect detection at some fixed distance (usually the transect line with the use of double-observer models. The assumption of full observer independence in the double-observer model is problematic, but can be addressed by using the point independence assumption which assumes there is one distance, the apex of the detection function, where the 2 observers are assumed independent. Aerially collected distance sampling data can have a unimodal shape and have been successfully modeled with a gamma detection function. Covariates in gamma detection models cause the apex of detection to shift depending upon covariate levels, making this model incompatible with the point independence assumption when using double-observer data. This paper reports a unimodal detection model based on a two-piece normal distribution that allows covariates, has only one apex, and is consistent with the point independence assumption when double-observer data are utilized. An aerial line-transect survey of black bears in Alaska illustrate how this method can be applied.

  4. Determination of As(III) and total inorganic As in water samples using an on-line solid phase extraction and flow injection hydride generation atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Sigrist, Mirna, E-mail: msigrist@fiq.unl.edu.ar [Laboratorio Central, Facultad de Ingenieria Quimica, Universidad Nacional del Litoral, Santiago del Estero 2654-Piso 6, (3000) Santa Fe (Argentina); Albertengo, Antonela; Beldomenico, Horacio [Laboratorio Central, Facultad de Ingenieria Quimica, Universidad Nacional del Litoral, Santiago del Estero 2654-Piso 6, (3000) Santa Fe (Argentina); Tudino, Mabel [Laboratorio de Analisis de Trazas, Departamento de Quimica Inorganica, Analitica y Quimica Fisica/INQUIMAE, Facultad de Ciencias Exactas y Naturales, Pabellon II, Ciudad Universitaria (1428), Buenos Aires (Argentina)

    2011-04-15

    A simple and robust on-line sequential injection system based on solid phase extraction (SPE) coupled to a flow injection hydride generation atomic absorption spectrometer (FI-HGAAS) with a heated quartz tube atomizer (QTA) was developed and optimized for the determination of As(III) in groundwater without any kind of sample pretreatment. The method was based on the selective retention of inorganic As(V) that was carried out by passing the filtered original sample through a cartridge containing a chloride-form strong anion exchanger. Thus the most toxic form, inorganic As(III), was determined fast and directly by AsH{sub 3} generation using 3.5 mol L{sup -1} HCl as carrier solution and 0.35% (m/v) NaBH{sub 4} in 0.025% NaOH as the reductant. Since the uptake of As(V) should be interfered by several anions of natural occurrence in waters, the effect of Cl{sup -}, SO{sub 4}{sup 2-}, NO{sub 3}{sup -}, HPO{sub 4}{sup 2-}, HCO{sub 3}{sup -} on retention was evaluated and discussed. The total soluble inorganic arsenic concentration was determined on aliquots of filtered samples acidified with concentrated HCl and pre-reduced with 5% KI-5% C{sub 6}H{sub 8}O{sub 6} solution. The concentration of As(V) was calculated by difference between the total soluble inorganic arsenic and As(III) concentrations. Detection limits (LODs) of 0.5 {mu}g L{sup -1} and 0.6 {mu}g L{sup -1} for As(III) and inorganic total As, respectively, were obtained for a 500 {mu}L sample volume. The obtained limits of detection allowed testing the water quality according to the national and international regulations. The analytical recovery for water samples spiked with As(III) ranged between 98% and 106%. The sampling throughput for As(III) determination was 60 samples h{sup -1}. The device for groundwater sampling was especially designed for the authors. Metallic components were avoided and the contact between the sample and the atmospheric oxygen was carried to a minimum. On-field arsenic species

  5. [Analysis of software for identifying spectral line of laser-induced breakdown spectroscopy based on LabVIEW].

    Science.gov (United States)

    Hu, Zhi-yu; Zhang, Lei; Ma, Wei-guang; Yan, Xiao-juan; Li, Zhi-xin; Zhang, Yong-zhi; Wang, Le; Dong, Lei; Yin, Wang-bao; Jia, Suo-tang

    2012-03-01

    Self-designed identifying software for LIBS spectral line was introduced. Being integrated with LabVIEW, the soft ware can smooth spectral lines and pick peaks. The second difference and threshold methods were employed. Characteristic spectrum of several elements matches the NIST database, and realizes automatic spectral line identification and qualitative analysis of the basic composition of sample. This software can analyze spectrum handily and rapidly. It will be a useful tool for LIBS.

  6. Use of Sequenom sample ID Plus® SNP genotyping in identification of FFPE tumor samples.

    Directory of Open Access Journals (Sweden)

    Jessica K Miller

    Full Text Available Short tandem repeat (STR analysis, such as the AmpFlSTR® Identifiler® Plus kit, is a standard, PCR-based human genotyping method used in the field of forensics. Misidentification of cell line and tissue DNA can be costly if not detected early; therefore it is necessary to have quality control measures such as STR profiling in place. A major issue in large-scale research studies involving archival formalin-fixed paraffin embedded (FFPE tissues is that varying levels of DNA degradation can result in failure to correctly identify samples using STR genotyping. PCR amplification of STRs of several hundred base pairs is not always possible when DNA is degraded. The Sample ID Plus® panel from Sequenom allows for human DNA identification and authentication using SNP genotyping. In comparison to lengthy STR amplicons, this multiplexing PCR assay requires amplification of only 76-139 base pairs, and utilizes 47 SNPs to discriminate between individual samples. In this study, we evaluated both STR and SNP genotyping methods of sample identification, with a focus on paired FFPE tumor/normal DNA samples intended for next-generation sequencing (NGS. The ability to successfully validate the identity of FFPE samples can enable cost savings by reducing rework.

  7. A case-control study of Yersinia enterocolitica infections in Auckland.

    Science.gov (United States)

    Satterthwaite, P; Pritchard, K; Floyd, D; Law, B

    1999-10-01

    To identify major risk factors for Yersinia enterocolitica (YE) and identify measures to reduce YE infections. A prospective case control study, group age matched, using 186 cases of YE identified by community pathology laboratories and 379 randomly selected controls. Conducted between April 1995 and June 1996 in Auckland, New Zealand. Face-to-face interviews used a standardised questionnaire examining exposures to factors potentially associated with YE infections including untreated water, unreticulated sewerage, consumption of selected foods, selected food handling practices and socio-demographic factors. Multivariate logistic regression was used to calculate adjusted odds ratios for the potential risk factors. Population attributable risk (PAR) was calculated for significant exposures. Having more than two people living in the home was more common among cases than controls (OR = 2.2). Town supply water (OR = 0.2), reticulated sewerage (OR = 0.34) and looking after a young child (OR = 0.51) were significantly less common. Of the meats, only pork (OR = 1.34) had a higher consumption rate, while bacon (OR = 0.75) and smallgoods (OR = 0.73) were consumed less frequently by cases than controls. Eating food from a sandwich bar was more frequent among cases (OR = 1.18). Fruit and vegetable consumption was marginally less (OR = 0.98). The population attributable risk of these factors was 0.89, implying that 89% of YE would be eliminated if adverse exposures were removed. The risk of YE illness is increased by contact with untreated water, unreticulated sewerage and consumption of pork. Investigation of non-town water supply, informal sewerage systems and methods of preparation and consumption of pork are recommended to determine how YE enters the human food chain.

  8. Computer simulation of ICP spectra: A new tool for the study of excitation, emission, and line overlap

    International Nuclear Information System (INIS)

    Blades, M.W.; Burton, L.L.

    1986-01-01

    It is well known that the relatively high temperature of ICP sources provides an excitation environment relatively free from dissociation and vaporization interferences and, in addition, produces intense analyte line spectra and hence high analytical sensitivity. However, this feature also introduces the potential for spectral overlaps from sample concomitants. The degree to which an analyte spectral line intensity can be corrected for interfering spectral overlaps depends on many factors including spectrometer resolution, sample composition and ICP operating conditions. The authors have been using a computer program to assist them in the study of ICP analyte emission spectra. This program is being used to study the spectral distribution of line intensity information and also to do detailed investigations on spectral overlaps in complex sample mixtures. As input data the program uses tabulated wavelengths, transition probabilities (gA values), partition functions, excitation energies of the transitions, ionization energy, temperature, and Doppler and Stark linewidths

  9. Caring behaviour perceptions from nurses of their first-line nurse managers.

    Science.gov (United States)

    Peng, Xiao; Liu, Yilan; Zeng, Qingsong

    2015-12-01

    Nursing is acknowledged as being the art and science of caring. According to the theory of nursing as caring, all persons are caring but not every behaviour of a person is caring. Caring behaviours in the relationship between first-line nurse managers and Registered Nurses have been studied to a lesser extent than those that exist between patients and nurses. Caring behaviour of first-line nurse managers from the perspective of Registered Nurses is as of yet unknown. Identifying caring behaviours may be useful as a reference for first-line nurse managers caring for nurses in a way that nurses prefer. To explore first-line nurse managers' caring behaviours from the perspective of Registered Nurses in mainland China. Qualitative study, using descriptive phenomenological approach. Fifteen Registered Nurses recruited by purposive sampling method took part in in-depth interviews. Data were analysed according to Colaizzi's technique. Three themes of first-line nurse managers' caring behaviours emerged: promoting professional growth, exhibiting democratic leadership and supporting work-life balance. A better understanding of the first-line nurse managers' caring behaviours is recognised. The three kinds of behaviours have significant meaning to nurse managers. Future research is needed to describe what first-line nurse managers can do to promote nurses' professional growth, increase the influence of democratic leadership, as well as support their work-life balance. © 2015 Nordic College of Caring Science.

  10. Determination of Pb-210 and U-238 in environment samples by direct measurement using low energy γ spectrometry

    International Nuclear Information System (INIS)

    Godoy, J.M. de; Mendonca, A.H.; Sachett, I.A.

    1985-01-01

    The determination of Pb-210 and U-238 by γ spectrometry in environmental samples was carried out using the 47 KeV (4%) line for Pb-210 and the 63 KeV (3,9%) line from Th-234 to U-238. An intrinsic Ge detector with 0,8 KeV resolution for the 60 KeV line of Am-41 was employed. The eficiency was determined by using the radionuclide water solution. The samples were measured in a cylindric geometry with 7 cm diameter and 3 cm hight with a mass ranging from 25 to 180g, depending on the density. The self absorption correction factor for each sample was determined by using an external source of Pb-210 and Am-241. The results showed good agreement with the radiochemical analysis values. The diferences were lower than 20%; the detection limit changed from sample to sample staying on the pCi/g range for the 200 minutes couting time. (Author) [pt

  11. Public Health Practice Report: water supply and sanitation in Chukotka and Yakutia, Russian Arctic.

    Science.gov (United States)

    Dudarev, Alexey A

    2018-12-01

    Information from 2013-2015 have been analysed on water accessibility, types of water service to households, use of water pretreatment, availability of sewerage, use of sewage treatment in Chukotka Autonomous Okrug and Yakutia Republic, based on evaluation information accessible in open sources, such as regional statistics and sanitary-epidemiologic reports. The main causes of the poor state of water supply and sanitation in the study regions include: very limited access to in-home running water (one-quarter of settlements in Chukotka and half of settlements in Yakutia have no regular water supply) and lack of centralised sewerage (78% and 94% of settlements correspondingly have no sewerage); lack of water pretreatment and sewage treatment, outdated technologies and systems; serious deterioration of facilities and networks, frequent accidents; secondary pollution of drinking water. Lack of open objective information on Russian Arctic water supply and sanitation in the materials of the regional and federal statistics hampers the assessment of the real state of affairs. The situation for water and sanitation supply in these Russian Arctic regions remains steadily unfavourable. A comprehensive intervention from national and regional governmental levels is urgently needed.

  12. On the analysis of line profile variations: A statistical approach

    International Nuclear Information System (INIS)

    McCandliss, S.R.

    1988-01-01

    This study is concerned with the empirical characterization of the line profile variations (LPV), which occur in many of and Wolf-Rayet stars. The goal of the analysis is to gain insight into the physical mechanisms producing the variations. The analytic approach uses a statistical method to quantify the significance of the LPV and to identify those regions in the line profile which are undergoing statistically significant variations. Line positions and flux variations are then measured and subject to temporal and correlative analysis. Previous studies of LPV have for the most part been restricted to observations of a single line. Important information concerning the range and amplitude of the physical mechanisms involved can be obtained by simultaneously observing spectral features formed over a range of depths in the extended mass losing atmospheres of massive, luminous stars. Time series of a Wolf-Rayet and two of stars with nearly complete spectral coverage from 3940 angstrom to 6610 angstrom and with spectral resolution of R = 10,000 are analyzed here. These three stars exhibit a wide range of both spectral and temporal line profile variations. The HeII Pickering lines of HD 191765 show a monotonic increase in the peak rms variation amplitude with lines formed at progressively larger radii in the Wolf-Rayet star wind. Two times scales of variation have been identified in this star: a less than one day variation associated with small scale flickering in the peaks of the line profiles and a greater than one day variation associated with large scale asymmetric changes in the overall line profile shapes. However, no convincing period phenomena are evident at those periods which are well sampled in this time series

  13. Cell Line Controls for the Genotyping of a Spectrum of Human Single Nucleotide Polymorphisms in the Clinical Laboratory.

    Science.gov (United States)

    Kimbacher, Christine; Paar, Christian; Freystetter, Andrea; Berg, Joerg

    2018-05-01

    Genotyping for clinically important single nucleotide polymorphisms (SNPs) is performed by many clinical routine laboratories. To support testing, quality controls and reference materials are needed. Those may be derived from residual patient samples, left over samples of external quality assurance schemes, plasmid DNA or DNA from cell lines. DNAs from cell lines are commutable and available in large amounts. DNA from 38 cell lines were examined for suitability as controls in 11 SNP assays that are frequently used in a clinical routine laboratory: FV (1691G>A), FII (20210G>A), PAI-1 4G/5G polymorphism, MTHFR (677C>T, 1298A>C), HFE (H63D, S65C, C282Y), APOE (E2, E3, E4), LPH (-13910C>T), UGT1A1 (*28, *36, *37), TPMT (*2, *3A, *3B, *3C), VKORC1 (-1639G>A, 1173C>T), CYP2C9 (*2, *3, *5). Genotyping was performed by real-time PCR with melting curve analysis and confirmed by bi-directional sequencing. We find an almost complete spectrum of genotypic constellations within these 38 cell lines. About 12 cell lines appear sufficient as genotypic controls for the 11 SNP assays by covering almost all of the genotypes. However, hetero- and homozygous genotypes for FII and the alleles TPMT*2, UGT1A1*37 and CYP2C9*5 were not detected in any of the cell lines. DNA from most of the examined cell lines appear suitable as quality controls for these SNP assays in the laboratory routine, as to the implementation of those assays or to prepare samples for quality assurance schemes. Our study may serve as a pilot to further characterize these cell lines to arrive at the status of reference materials.

  14. Oncostatin M promotes STAT3 activation, VEGF production, and invasion in osteosarcoma cell lines

    International Nuclear Information System (INIS)

    Fossey, Stacey L; Bear, Misty D; Kisseberth, William C; Pennell, Michael; London, Cheryl A

    2011-01-01

    We have previously demonstrated that both canine and human OSA cell lines, as well as 8 fresh canine OSA tumor samples, exhibit constitutive phosphorylation of STAT3, and that this correlates with enhanced expression of matrix metalloproteinase-2 (MMP2). While multiple signal transduction pathways can result in phosphorylation of STAT3, stimulation of the cytokine receptor gp130 through either IL-6 or Oncostatin M (OSM) is the most common mechanism through which STAT3 is activated. The purpose of this study was to evaluate the role of IL-6 and OSM stimulation on both canine and human OSA cell lines to begin to determine the role of these cytokines in the biology of OSA. RT-PCR and Western blotting were used to interrogate the consequences of OSM and IL-6 stimulation of OSA cell lines. OSA cells were stimulated with OSM and/or hepatocyte growth factor (HGF) and the effects on MMP2 activity (gel zymography), proliferation (CyQUANT), invasion (Matrigel transwell assay), and VEGF production (Western blotting, ELISA) were assessed. The small molecule STAT3 inhibitor LLL3 was used to investigate the impact of STAT3 inhibition following OSM stimulation of OSA cells. Our data demonstrate that the OSM receptor (OSMR), but not IL-6 or its receptor, is expressed by all human and canine OSA cell lines and canine OSA tumor samples; additionally, OSM expression was noted in all tumor samples. Treatment of OSA cell lines with OSM induced phosphorylation of STAT3, Src, and JAK2. OSM stimulation also resulted in a dose dependent increase in MMP2 activity and VEGF expression that was markedly reduced following treatment with the small molecule STAT3 inhibitor LLL3. Lastly, OSM stimulation of OSA cell lines enhanced invasion through Matrigel, particularly in the presence of rhHGF. In contrast, both OSM and HGF stimulation of OSA cell lines did not alter their proliferative capacity. These data indicate OSM stimulation of human and canine OSA cells induces STAT3 activation, thereby

  15. Oncostatin M promotes STAT3 activation, VEGF production, and invasion in osteosarcoma cell lines

    Directory of Open Access Journals (Sweden)

    Kisseberth William C

    2011-04-01

    Full Text Available Abstract Background We have previously demonstrated that both canine and human OSA cell lines, as well as 8 fresh canine OSA tumor samples, exhibit constitutive phosphorylation of STAT3, and that this correlates with enhanced expression of matrix metalloproteinase-2 (MMP2. While multiple signal transduction pathways can result in phosphorylation of STAT3, stimulation of the cytokine receptor gp130 through either IL-6 or Oncostatin M (OSM is the most common mechanism through which STAT3 is activated. The purpose of this study was to evaluate the role of IL-6 and OSM stimulation on both canine and human OSA cell lines to begin to determine the role of these cytokines in the biology of OSA. Methods RT-PCR and Western blotting were used to interrogate the consequences of OSM and IL-6 stimulation of OSA cell lines. OSA cells were stimulated with OSM and/or hepatocyte growth factor (HGF and the effects on MMP2 activity (gel zymography, proliferation (CyQUANT, invasion (Matrigel transwell assay, and VEGF production (Western blotting, ELISA were assessed. The small molecule STAT3 inhibitor LLL3 was used to investigate the impact of STAT3 inhibition following OSM stimulation of OSA cells. Results Our data demonstrate that the OSM receptor (OSMR, but not IL-6 or its receptor, is expressed by all human and canine OSA cell lines and canine OSA tumor samples; additionally, OSM expression was noted in all tumor samples. Treatment of OSA cell lines with OSM induced phosphorylation of STAT3, Src, and JAK2. OSM stimulation also resulted in a dose dependent increase in MMP2 activity and VEGF expression that was markedly reduced following treatment with the small molecule STAT3 inhibitor LLL3. Lastly, OSM stimulation of OSA cell lines enhanced invasion through Matrigel, particularly in the presence of rhHGF. In contrast, both OSM and HGF stimulation of OSA cell lines did not alter their proliferative capacity. Conclusions These data indicate OSM stimulation of

  16. Use of coliform bacteria for the detection of on-line leakage in drinking water

    International Nuclear Information System (INIS)

    Bibi, S.; Karim, H.M.A.; Mashiatullah, A.; Sajjad, I.

    1996-01-01

    In this method, rupture or leakage in under ground water pipes is detected simply by taking the water samples from the main supply lines of the houses and incubating them at 40 deg. C for sixteen hours, colonies (developed with yellow colour) are counted with colony counter. Thirteen samples (in triplicate) collected from different houses in the congested localities during repair work of the major supply line and all of them after test showed heavy rate of pollution. The experiment was repeated for the same locality and sampling sites after completion of repair work. This time the rate of pollution decreases very much showing drastically low growth of microorganisms except for two points. For two further investigation of the nearly leakages at these points, 13 samples (in triplicate) were again collected in serial wise number of houses. Two points of the leakage were identified where the growth rate of the microorganisms was abruptly high between two consecutive houses or opposite houses depending upon the supply of water pipe lines showing the leakage of houses. Two points of the leakage were identified where the growth rate of the microorganisms was abruptly high between two consecutive houses or opposite houses depending upon the supply of water pipe lines showing the leakage of he pipes. This method is useful and causes no health hazard to the population and gives best results where the water supply is on intermittent basis. The technique is specially useful in the remote areas of the country where research facilities are not available and the Pacqualab is a field instrument. So it is handy and rapid method for the detection of leakage in underground water supplies in the remote areas of the country. (author)

  17. Anatomy of the thriple oxygen isotope Terrestrial Fractionatoin Line

    Science.gov (United States)

    Sharp, Z. D.; Pack, A.

    2017-12-01

    In the triple oxygen isotope system, it is well established that the δ17O value of nearly all terrestrial materials is approximately ½ that of the corresponding δ18O value. In triple isotope space then, all samples plot on a slope 1/2 line, termed the Terrestrial Fractionation Line (TFL). It has recently been recognized that subtle, but significant departures from the TFL exist, given by Δ'17O = δ'17O -λ× δ'18O + γ, where λ is the slope of the TFL (γ is the y-intercept and assumed to be zero in most studies). There have been many published λ values, ranging from 0.52 to 0.5305. λ values determined from a best-fit to rock and mineral samples range from 0.5244 to 0.5266. λ values from meteoric waters are 0.527 to 0.528 (γ = 0.007 to 0.034), explained by equilibrium and kinetic processes. Extreme polar glacial samples define a λ >0.53. As pointed out by Matsuhisia et al. (GCA, 1978), there is no single factor that controls the δ17O-δ18O slope, and clearly there is no `correct' TFL line. However, some generalities can be noted. 1) Meteoric waters generally plot with a λ = 0.528 with a Δ'17O = 0.033. At both high and low δ18O values, the Δ'17O values of meteoritic waters decrease. Mantle derived samples plot in a limited δ space, with δ18O values of 5-9‰ and a Δ'17O of -0.05‰. Rock and mineral samples falling outside this narrow range have undergone interaction with meteoric or ocean water at some point in their history, either by alteration or neoform mineral growth. The quartz-water triple isotope fractionation factor varies with temperatures, ranging from 0.5237 to 0.5266 at 0°C and 200°C, respective. A fit to published rock data gives an overall λ = 0.5237-0.5240. These results are most likely explained by the sum of hydrothermal and low-temperature mineral-water fractionations. Attempting to place any significance on a TFL from a set of data in unwarranted without understanding the processes controlling the isotopic compositions of

  18. Terahertz in-line digital holography of human hepatocellular carcinoma tissue

    Science.gov (United States)

    Rong, Lu; Latychevskaia, Tatiana; Chen, Chunhai; Wang, Dayong; Yu, Zhengping; Zhou, Xun; Li, Zeyu; Huang, Haochong; Wang, Yunxin; Zhou, Zhou

    2015-02-01

    Terahertz waves provide a better contrast in imaging soft biomedical tissues than X-rays, and unlike X-rays, they cause no ionisation damage, making them a good option for biomedical imaging. Terahertz absorption imaging has conventionally been used for cancer diagnosis. However, the absorption properties of a cancerous sample are influenced by two opposing factors: an increase in absorption due to a higher degree of hydration and a decrease in absorption due to structural changes. It is therefore difficult to diagnose cancer from an absorption image. Phase imaging can thus be critical for diagnostics. We demonstrate imaging of the absorption and phase-shift distributions of 3.2 mm × 2.3 mm × 30-μm-thick human hepatocellular carcinoma tissue by continuous-wave terahertz digital in-line holography. The acquisition time of a few seconds for a single in-line hologram is much shorter than that of other terahertz diagnostic techniques, and future detectors will allow acquisition of meaningful holograms without sample dehydration. The resolution of the reconstructions was enhanced by sub-pixel shifting and extrapolation. Another advantage of this technique is its relaxed minimal sample size limitation. The fibrosis indicated in the phase distribution demonstrates the potential of terahertz holographic imaging to obtain a more objective, early diagnosis of cancer.

  19. Terahertz in-line digital holography of human hepatocellular carcinoma tissue.

    Science.gov (United States)

    Rong, Lu; Latychevskaia, Tatiana; Chen, Chunhai; Wang, Dayong; Yu, Zhengping; Zhou, Xun; Li, Zeyu; Huang, Haochong; Wang, Yunxin; Zhou, Zhou

    2015-02-13

    Terahertz waves provide a better contrast in imaging soft biomedical tissues than X-rays, and unlike X-rays, they cause no ionisation damage, making them a good option for biomedical imaging. Terahertz absorption imaging has conventionally been used for cancer diagnosis. However, the absorption properties of a cancerous sample are influenced by two opposing factors: an increase in absorption due to a higher degree of hydration and a decrease in absorption due to structural changes. It is therefore difficult to diagnose cancer from an absorption image. Phase imaging can thus be critical for diagnostics. We demonstrate imaging of the absorption and phase-shift distributions of 3.2 mm × 2.3 mm × 30-μm-thick human hepatocellular carcinoma tissue by continuous-wave terahertz digital in-line holography. The acquisition time of a few seconds for a single in-line hologram is much shorter than that of other terahertz diagnostic techniques, and future detectors will allow acquisition of meaningful holograms without sample dehydration. The resolution of the reconstructions was enhanced by sub-pixel shifting and extrapolation. Another advantage of this technique is its relaxed minimal sample size limitation. The fibrosis indicated in the phase distribution demonstrates the potential of terahertz holographic imaging to obtain a more objective, early diagnosis of cancer.

  20. The Quasar Fraction in Low-Frequency Selected Complete Samples and Implications for Unified Schemes

    Science.gov (United States)

    Willott, Chris J.; Rawlings, Steve; Blundell, Katherine M.; Lacy, Mark

    2000-01-01

    Low-frequency radio surveys are ideal for selecting orientation-independent samples of extragalactic sources because the sample members are selected by virtue of their isotropic steep-spectrum extended emission. We use the new 7C Redshift Survey along with the brighter 3CRR and 6C samples to investigate the fraction of objects with observed broad emission lines - the 'quasar fraction' - as a function of redshift and of radio and narrow emission line luminosity. We find that the quasar fraction is more strongly dependent upon luminosity (both narrow line and radio) than it is on redshift. Above a narrow [OII] emission line luminosity of log(base 10) (L(sub [OII])/W) approximately > 35 [or radio luminosity log(base 10) (L(sub 151)/ W/Hz.sr) approximately > 26.5], the quasar fraction is virtually independent of redshift and luminosity; this is consistent with a simple unified scheme with an obscuring torus with a half-opening angle theta(sub trans) approximately equal 53 deg. For objects with less luminous narrow lines, the quasar fraction is lower. We show that this is not due to the difficulty of detecting lower-luminosity broad emission lines in a less luminous, but otherwise similar, quasar population. We discuss evidence which supports at least two probable physical causes for the drop in quasar fraction at low luminosity: (i) a gradual decrease in theta(sub trans) and/or a gradual increase in the fraction of lightly-reddened (0 approximately quasar luminosity; and (ii) the emergence of a distinct second population of low luminosity radio sources which, like M8T, lack a well-fed quasar nucleus and may well lack a thick obscuring torus.

  1. Off-Line Robust Constrained MPC for Linear Time-Varying Systems with Persistent Disturbances

    Directory of Open Access Journals (Sweden)

    P. Bumroongsri

    2014-01-01

    Full Text Available An off-line robust constrained model predictive control (MPC algorithm for linear time-varying (LTV systems is developed. A novel feature is the fact that both model uncertainty and bounded additive disturbance are explicitly taken into account in the off-line formulation of MPC. In order to reduce the on-line computational burdens, a sequence of explicit control laws corresponding to a sequence of positively invariant sets is computed off-line. At each sampling time, the smallest positively invariant set containing the measured state is determined and the corresponding control law is implemented in the process. The proposed MPC algorithm can guarantee robust stability while ensuring the satisfaction of input and output constraints. The effectiveness of the proposed MPC algorithm is illustrated by two examples.

  2. The current role of on-line extraction approaches in clinical and forensic toxicology.

    Science.gov (United States)

    Mueller, Daniel M

    2014-08-01

    In today's clinical and forensic toxicological laboratories, automation is of interest because of its ability to optimize processes, to reduce manual workload and handling errors and to minimize exposition to potentially infectious samples. Extraction is usually the most time-consuming step; therefore, automation of this step is reasonable. Currently, from the field of clinical and forensic toxicology, methods using the following on-line extraction techniques have been published: on-line solid-phase extraction, turbulent flow chromatography, solid-phase microextraction, microextraction by packed sorbent, single-drop microextraction and on-line desorption of dried blood spots. Most of these published methods are either single-analyte or multicomponent procedures; methods intended for systematic toxicological analysis are relatively scarce. However, the use of on-line extraction will certainly increase in the near future.

  3. Service line structure and decision-maker attention in three health systems: Implications for patient-centered care.

    Science.gov (United States)

    Louis, Christopher J; Clark, Jonathan R; Gray, Barbara; Brannon, Diane; Parker, Victoria

    2017-06-15

    Scholars have noted a disconnect between the level at which structure is typically examined (the organization) and the level at which the relevant coordination takes place (service delivery). Accordingly, our understanding of the role structure plays in care coordination is limited. In this article, we explore service line structure, with an aim of advancing our understanding of the role service line structure plays in producing coordinated, patient-centered care. We do so by giving special attention to the cognitive roots of patient-centeredness. Our exploratory study relied on comparative case studies of the breast cancer service lines in three health systems. Nonprobability discriminative snowball sampling was used to identify the final sample of key informants. We employed a grounded approach to analyzing and interpreting the data. We found substantial variation across the three service lines in terms of their structure. We also found corresponding variation across the three case sites in terms of where informant attention was primarily focused in the process of coordinating care. Drawing on the attention-based view of the firm, our results draw a clear connection between structural characteristics and the dominant focus of attention (operational tactics, provider roles and relationships, or patient needs and engagement) in health care service lines. Our exploratory results suggest that service line structures influence attention in two ways: (a) by regulating the type and intensity of the problems facing service line participants and (b) by encouraging (or discouraging) a shared purpose around patient needs. Patient-centered attention-a precursor to coordinated, patient-centered care-depends on the internal choices organizations make around service line structure. Moreover, a key task for organizational and service line leaders is to structure service lines to create a context that minimizes distractions and enables care providers to focus their attention on

  4. Two Dimensional Symmetric Correlation Functions of the S Operator and Two Dimensional Fourier Transforms: Considering the Line Coupling for P and R Lines of Linear Molecules

    Science.gov (United States)

    Ma, Q.; Boulet, C.; Tipping, R. H.

    2014-01-01

    The refinement of the Robert-Bonamy (RB) formalism by considering the line coupling for isotropic Raman Q lines of linear molecules developed in our previous study [Q. Ma, C. Boulet, and R. H. Tipping, J. Chem. Phys. 139, 034305 (2013)] has been extended to infrared P and R lines. In these calculations, the main task is to derive diagonal and off-diagonal matrix elements of the Liouville operator iS1 - S2 introduced in the formalism. When one considers the line coupling for isotropic Raman Q lines where their initial and final rotational quantum numbers are identical, the derivations of off-diagonal elements do not require extra correlation functions of the ^S operator and their Fourier transforms except for those used in deriving diagonal elements. In contrast, the derivations for infrared P and R lines become more difficult because they require a lot of new correlation functions and their Fourier transforms. By introducing two dimensional correlation functions labeled by two tensor ranks and making variable changes to become even functions, the derivations only require the latters' two dimensional Fourier transforms evaluated at two modulation frequencies characterizing the averaged energy gap and the frequency detuning between the two coupled transitions. With the coordinate representation, it is easy to accurately derive these two dimensional correlation functions. Meanwhile, by using the sampling theory one is able to effectively evaluate their two dimensional Fourier transforms. Thus, the obstacles in considering the line coupling for P and R lines have been overcome. Numerical calculations have been carried out for the half-widths of both the isotropic Raman Q lines and the infrared P and R lines of C2H2 broadened by N2. In comparison with values derived from the RB formalism, new calculated values are significantly reduced and become closer to measurements.

  5. Radio molecular maser line study of symbiotic stars

    International Nuclear Information System (INIS)

    Cohen, N.L.; Ghigo, F.D.

    1980-01-01

    A sample of symbiotic stars has been searched for maser emission from the 1665- and 1667-MHz OH mainlines, the 22-GHz H 2 O line, and the 43-GHz SiO line. R Aqr remains the sole symbiotic for which maser emission has been detected. Its SiO spectrum reveals a pedestal of emission with a narrow superposed peak at V/sub LSR/ -26.4 +- 0.7 km/s. The line's existence and the pedestal feature are both characteristic of SiO lines found in late-type variables by Snyder et al. [Astrophys. J. 224, 512 (1978)]. For the other symbiotic stars, it is possible that conditions favorable for maser emission have been suppressed by the presence of a hot companion. Alternatively our findings may argue against the presence of late-type variables in symbiotic stars. In either case, R Aqr seems to be in a class by itself. We cannot confirm the suggestion that R Aqr is a binary, since the spectral feature has not shifted noticeably in the two years since the observations by Lepine, LeSqueren, and Scalise [Astrophys. J. 225, 869 (1978)]. However, we point out that monitoring the pedestal emission over a number of years is the least ambiguous way to discern any velocity shift that might result from orbital motion

  6. Virologic failure of protease inhibitor-based second-line antiretroviral therapy without resistance in a large HIV treatment program in South Africa.

    Directory of Open Access Journals (Sweden)

    Julie H Levison

    Full Text Available We investigated the prevalence of wild-type virus (no major drug resistance and drug resistance mutations at second-line antiretroviral treatment (ART failure in a large HIV treatment program in South Africa.HIV-infected patients ≥ 15 years of age who had failed protease inhibitor (PI-based second-line ART (2 consecutive HIV RNA tests >1000 copies/ml on lopinavir/ritonavir, didanosine, and zidovudine were identified retrospectively. Patients with virologic failure were continued on second-line ART. Genotypic testing for drug resistance was performed on frozen plasma samples obtained closest to and after the date of laboratory confirmed second-line ART failure. Of 322 HIV-infected patients on second-line ART, 43 were adults with confirmed virologic failure, and 33 had available plasma for viral sequencing. HIV-1 RNA subtype C predominated (n = 32, 97%. Mean duration on ART (SD prior to initiation of second-line ART was 23 (17 months, and time from second-line ART initiation to failure was 10 (9 months. Plasma samples were obtained 7(9 months from confirmed failure. At second-line failure, 22 patients (67% had wild-type virus. There was no major resistance to PIs found. Eleven of 33 patients had a second plasma sample taken 8 (5.5 months after the first. Median HIV-1 RNA and the genotypic resistance profile were unchanged.Most patients who failed second-line ART had wild-type virus. We did not observe evolution of resistance despite continuation of PI-based ART after failure. Interventions that successfully improve adherence could allow patients to continue to benefit from second-line ART therapy even after initial failure.

  7. REQUIREMENTS AND GUIDELINES FOR NSLS EXPERIMENTAL BEAM LINE VACUUM SYSTEMS-REVISION B.

    Energy Technology Data Exchange (ETDEWEB)

    FOERSTER,C.

    1999-05-01

    Typical beam lines are comprised of an assembly of vacuum valves and shutters referred to as a ''front end'', optical elements to monochromatize, focus and split the photon beam, and an experimental area where a target sample is placed into the photon beam and data from the interaction is detected and recorded. Windows are used to separate sections of beam lines that are not compatible with storage ring ultra high vacuum. Some experimental beam lines share a common vacuum with storage rings. Sections of beam lines are only allowed to vent up to atmospheric pressure using pure nitrogen gas after a vacuum barrier is established to protect ring vacuum. The front end may only be bled up when there is no current in the machine. This is especially true on the VUV storage ring where for most experiments, windows are not used. For the shorter wavelength, more energetic photons of the x-ray ring, beryllium windows are used at various beam line locations so that the monochromator, mirror box or sample chamber may be used in a helium atmosphere or rough vacuum. The window separates ring vacuum from the environment of the downstream beam line components. The stored beam lifetime in the storage rings and the maintenance of desirable reflection properties of optical surfaces depend upon hydrocarbon-free, ultra-high vacuum systems. Storage ring vacuum systems will operate at pressures of {approximately} 1 x 10{sup {minus}10} Torr without beam and {approximately} 1 x 10{sup {minus}9} Torr with beam. Systems are free of hydrocarbons in the sense that no pumps, valves, etc. containing organics are used. Components are all-metal, chemically cleaned and bakeable. To the extent that beam lines share a common vacuum with the storage ring, the same criteria will hold for beam line components. The design philosophy for NSLS beam lines is to use all-metal, hydrocarbon-free front end components and recommend that experimenters use this approach for common vacuum hardware

  8. Determination of antibiotic compounds in water by on-line SPE-LC/MSD.

    Science.gov (United States)

    Choi, Keun-Joo; Kim, Sang-Goo; Kim, Chang-won; Kim, Seung-Hyun

    2007-01-01

    This study attempts to provide an improved approach for the analysis of antibiotics, which normally exist at low concentration in complex matrices such as receiving streams of wastewater treatment plant discharge. The analytical method developed in this study combines an existing pretreatment technique of solid-phase extraction (SPE) with liquid chromatography mass spectrometry (LC/MSD) through on-line connection. The on-line connection suppressed the target loss by keeping the cartridge from drying, which resulted in improvement of the recovery and saving of the analytical time. For the on-line solid-phase extraction of 10 ml water samples, recoveries were between 74.3% and 116.5% and average LOQ was 0.11 microg l(-1) for the sulfonamide antibiotics (SA) and 0.09 microg l(-1) for the tetracycline antibiotics (TA). Application of the developed method for the analysis of fourteen antibiotics revealed that several antibiotics were detected at concentrations above the LOQ in ARW. Treated and untreated sewage and agricultural wastewater were mostly responsible for the antibiotics contamination of the river. Antibiotics were detected at much higher concentrations in the agricultural wastewater sample than in the sewage sample, implying substantial use of antibiotics in the agricultural industry. Wastewater treatment was generally effective in separation of the antibiotics tested in this study. The extent of the treatment depended on the type of antibiotics. Hydrophobic antibiotics were more effectively separated from the solution than hydrophilic antibiotics.

  9. Lining seam elimination algorithm and surface crack detection in concrete tunnel lining

    Science.gov (United States)

    Qu, Zhong; Bai, Ling; An, Shi-Quan; Ju, Fang-Rong; Liu, Ling

    2016-11-01

    Due to the particularity of the surface of concrete tunnel lining and the diversity of detection environments such as uneven illumination, smudges, localized rock falls, water leakage, and the inherent seams of the lining structure, existing crack detection algorithms cannot detect real cracks accurately. This paper proposed an algorithm that combines lining seam elimination with the improved percolation detection algorithm based on grid cell analysis for surface crack detection in concrete tunnel lining. First, check the characteristics of pixels within the overlapping grid to remove the background noise and generate the percolation seed map (PSM). Second, cracks are detected based on the PSM by the accelerated percolation algorithm so that the fracture unit areas can be scanned and connected. Finally, the real surface cracks in concrete tunnel lining can be obtained by removing the lining seam and performing percolation denoising. Experimental results show that the proposed algorithm can accurately, quickly, and effectively detect the real surface cracks. Furthermore, it can fill the gap in the existing concrete tunnel lining surface crack detection by removing the lining seam.

  10. The use of on-line ion chromatography for high temperature and high pressure reaction studies

    International Nuclear Information System (INIS)

    Lynch, G.J.

    1993-10-01

    This paper describes the use of on-line ion chromatography as a tool for chemistry reaction studies in small volume systems. The technique was used to study chemistry behavior in a high temperature and high pressure autoclave system. A dual analyzer, multi-channel on-line ion chromatograph (IC) was configured to automate the sampling and analysis. Analytical channels were set up for analysis of inorganic anions, monovalent cations, conductivity, and pH. Conductivity and pH were measured using the IC as a flow injection analyzer. Use of the IC system provides significant advantages over conventional sampling and analysis techniques: Reduction in sample volume, a closed sampling system that protects air or light sensitive analytes from breakdown, around-the-clock test performance combined with automatic calibration and quality control checking, and detection and tracking of reaction products or unexpected contaminants. Methods used to correct measured concentrations for the effects of sampling and for calculation of control chemical loss half-lives are presented. A limited evaluation of the flow injection analysis methods for conductivity and pH is provided

  11. Stark broadening of isolated lines from high-Z emitters in dense plasmas

    International Nuclear Information System (INIS)

    Weisheit, J.C.; Pollock, E.L.

    1980-09-01

    The joint distribution of the electric microfield and its longitudinal derivative is required for the calculation of line profiles for the He-like ions in very dense plasmas. We used a molecular dynamics code to compute exact distributions in single- and multi-component plasmas, and then we investigated various analytical approximations to these results. We found that a simplified, two-nearest-neighbor scheme leads to surprisingly accurate distribution functions. Our results are illustrated by sample profiles for Ne +8 and Ar +16 resonance lines

  12. The description of compton lines in energy-dispersive x-ray Fluorescence

    International Nuclear Information System (INIS)

    Van Gysel, Mon; Van Espen, P.J.M.

    2001-01-01

    Energy-Dispersive X-Ray Fluorescence (ED-XRF) is a non-destructive technique for the element analysis in a concentration range ppm - % making use of X rays up to 100 keV. Generally, two photon matter interactions occur, respectively absorption and scattering. The absorption of incident photons gives raise to characteristic lines. Scattering gives an incoherent and a coherent line. A Gaussian peak model is adequate to describe the characteristic and coherent scattered lines. Incoherent lines appear as non-Gaussian, broadened peaks. The profile of a Compton peak is complex. It depends on the geometry and the composition of the sample. Especially, when analyzing a low Z matrix; dominant scattering and multiple scattering may cause large interferences. The absence of an appropriate fitting model makes the Compton profile seen as a limiting factor in the evaluation of spectra. An accurate description of incoherent lines should improve quantitative analysis. Therefore, a suitable fitting model, making use of the expertise of non-linear least squares procedures and Monte-Carlo calculations was systematically investigated. The proposed model, containing a modified Gaussian, is tested on experimental data recorded with a HPGe detector

  13. Phase Velocity Estimation of a Microstrip Line in a Stoichiometric Periodically Domain-Inverted LiTaO3 Modulator Using Electro-Optic Sampling Technique

    Directory of Open Access Journals (Sweden)

    Shintaro Hisatake

    2008-01-01

    Full Text Available We estimate the phase velocity of a modulation microwave in a quasi-velocity-matched (QVM electro-optic (EO phase modulator (QVM-EOM using EO sampling which is accurate and the most reliable technique for measuring voltage waveforms at an electrode. The substrate of the measured QVM-EOM is a stoichiometric periodically domain-inverted LiTaO3 crystal. The electric field of a standing wave in a resonant microstrip line (width: 0.5 mm, height: 0.5 mm is measured by employing a CdTe crystal as an EO sensor. The wavelength of the traveling microwave at 16.0801 GHz is determined as 3.33 mm by fitting the theoretical curve to the measured electric field distribution. The phase velocity is estimated as vm=5.35×107 m/s, though there exists about 5% systematic error due to the perturbation by the EO sensor. Relative dielectric constant of εr=41.5 is led as the maximum likelihood value that derives the estimated phase velocity.

  14. Analysis of special recovery samples by Pu(III) spectrophotometry

    International Nuclear Information System (INIS)

    Van Hare, D.R.

    1985-11-01

    A simple spectrophotometric method has been developed to determine the plutonium concentration of FB-Line Special Recovery samples. The method is applicable over the 1 to 150 g/L range, with an accuracy and precision of better than 1%. 9 refs., 3 figs., 3 tabs

  15. Effect of a polyethylene-lined administration set on the availability of diazepam injection.

    Science.gov (United States)

    Hancock, B G; Black, C D

    1985-02-01

    Delivery of diazepam through a polyethylene-lined i.v. administration set and through a polyvinyl chloride (PVC) set was compared. Diazepam was prepared in concentrations of 50 mg/500 mL and 100 mg/500 mL in 0.9% sodium chloride injection and 5% dextrose injection in glass containers. Diazepam concentrations were measured by high-performance liquid chromatography at 0 through 5 hours in samples collected simultaneously from the glass solution containers and from the distal ends of a PVC administration set and a polyethylene-lined (non-PVC) set. Flow rates of 50 and 100 mL/hr were tested. For the non-PVC sets, diazepam concentration in the infusate was not significantly different from concentration in the glass container at any sampling time. The overall percentage of diazepam recovered was 100.7 +/- 6.8%. For the PVC sets, diazepam concentration in the infusate was less than in the container at all sampling times, and the overall percentage of diazepam recovered was 65.4 +/- 13.3% (significantly different from delivery for the non-PVC sets). Delivery through the non-PVC sets was not affected by flow rate, type of solution, or concentration of diazepam. For infusion periods of up to five hours, delivery of diazepam through polyethylene-lined i.v. administration sets was superior to delivery through polyvinyl chloride sets.

  16. Non-LTE, line-blanketed model atmospheres for late O- and early B-type stars

    Science.gov (United States)

    Grigsby, James A.; Morrison, Nancy D.; Anderson, Lawrence S.

    1992-01-01

    The use of non-LTE line-blanketed model atmospheres to analyze the spectra of hot stars is reported. The stars analyzed are members of clusters and associations, have spectral types in the range O9-B2 and luminosity classes in the range III-IV, have slow to moderate rotation, and are photometrically constant. Sampled line opacities of iron-group elements were incorporated in the radiative transfer solution; solar abundances were assumed. Good to excellent agreement is obtained between the computed profiles and essentially all the line profiles used to fix the model, and reliable stellar parameters are derived. The synthetic M II 5581 equivalent widths agree well with the observed ones at the low end of the temperature range studied, but, above 25,000 K, the synthetic line is generally stronger than the observed line. The behavior of the observed equivalent widths of N II, N III, C II and C III lines as a function of Teff is studied. Most of the lines show much scatter, with no consistent trend that could indicate abundance differences from star to star.

  17. High Line

    DEFF Research Database (Denmark)

    Kiib, Hans

    2015-01-01

    At just over 10 meters above street level, the High Line extends three kilometers through three districts of Southwestern Manhattan in New York. It consists of simple steel construction, and previously served as an elevated rail line connection between Penn Station on 34th Street and the many....... The High Line project has been carried out as part of an open conversion strategy. The result is a remarkable urban architectural project, which works as a catalyst for the urban development of Western Manhattan. The greater project includes the restoration and reuse of many old industrial buildings...

  18. First-order and tricritical wetting transitions in the two-dimensional Ising model caused by interfacial pinning at a defect line.

    Science.gov (United States)

    Trobo, Marta L; Albano, Ezequiel V; Binder, Kurt

    2014-08-01

    We present a study of the critical behavior of the Blume-Capel model with three spin states (S=±1,0) confined between parallel walls separated by a distance L where competitive surface magnetic fields act. By properly choosing the crystal field (D), which regulates the density of nonmagnetic species (S=0), such that those impurities are excluded from the bulk (where D=-∞) except in the middle of the sample [where D(M)(L/2)≠-∞], we are able to control the presence of a defect line in the middle of the sample and study its influence on the interface between domains of different spin orientations. So essentially we study an Ising model with a defect line but, unlike previous work where defect lines in Ising models were defined via weakened bonds, in the present case the defect line is due to mobile vacancies and hence involves additional entropy. In this way, by drawing phase diagrams, i.e., plots of the wetting critical temperature (T(w)) versus the magnitude of the crystal field at the middle of the sample (D(M)), we observe curves of (first-) second-order wetting transitions for (small) high values of D(M). Theses lines meet in tricritical wetting points, i.e., (T(w)(tc),D(M)(tc)), which also depend on the magnitude of the surface magnetic fields. It is found that second-order wetting transitions satisfy the scaling theory for short-range interactions, while first-order ones do not exhibit hysteresis, provided that small samples are used, since fluctuations wash out hysteretic effects. Since hysteresis is observed in large samples, we performed extensive thermodynamic integrations in order to accurately locate the first-order transition points, and a rather good agreement is found by comparing such results with those obtained just by observing the jump of the order parameter in small samples.

  19. Skateboarding: more dangerous than roller skating or in-line skating.

    Science.gov (United States)

    Osberg, J S; Schneps, S E; Di Scala, C; Li, G

    1998-10-01

    To describe the circumstances, severity, and outcomes of skating-related injuries among children admitted to trauma centers. A cross-sectional comparison of roller skaters (n = 154), in-line skaters (n = 190), and skateboarders (n = 254) aged 5 to 19 years who were hospitalized with injuries. Seventy-nine hospitals and pediatric trauma centers participating in the National Pediatric Trauma Registry between October 1988 and April 1997. Three quarters (75.8%) of the study sample were male, nearly half (47.8%) were injured on roads, and more than one third (37.1%) had head injuries. Among skateboarders, 50.8% had head injuries compared with 33.7% of in-line skaters and 18.8% of roller skaters (Pskateboarders were 8 times more likely to be severe or critical compared with roller skaters' injuries and more than 2 times as likely to be severe or critical compared with in-line skaters' injuries. Mean hospital length of stay was 6.0 days for skateboarders, 3.4 days for in-line skaters, and 2.4 days for roller skaters (PSkateboarders were more likely to be male and to be injured on roads than were in-line skaters or roller skaters. Skateboarding-related injuries are more severe and have more serious consequences than roller skating or in-line skating injuries. Research is needed to identify ergonomic and behavioral factors responsible for higher head injury risk to skateboarders, and interventions are needed to reduce the risk.

  20. Focussed ion beam thin sample microanalysis using a field emission gun electron probe microanalyser

    Science.gov (United States)

    Kubo, Y.

    2018-01-01

    Field emission gun electron probe microanalysis (FEG-EPMA) in conjunction with wavelength-dispersive X-ray spectrometry using a low acceleration voltage (V acc) allows elemental analysis with sub-micrometre lateral spatial resolution (SR). However, this degree of SR does not necessarily meet the requirements associated with increasingly miniaturised devices. Another challenge related to performing FEG-EPMA with a low V acc is that the accuracy of quantitative analyses is adversely affected, primarily because low energy X-ray lines such as the L- and M-lines must be employed and due to the potential of line interference. One promising means of obtaining high SR with FEG-EPMA is to use thin samples together with high V acc values. This mini-review covers the basic principles of thin-sample FEG-EPMA and describes an application of this technique to the analysis of optical fibres. Outstanding issues related to this technique that must be addressed are also discussed, which include the potential for electron beam damage during analysis of insulating materials and the development of methods to use thin samples for quantitative analysis.