WorldWideScience

Sample records for sevillita nm site

  1. 50 CFR Table 12 to Part 679 - Steller Sea Lion Protection Areas, 3nm No Groundfish Fishing Sites

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 9 2010-10-01 2010-10-01 false Steller Sea Lion Protection Areas, 3nm No... EXCLUSIVE ECONOMIC ZONE OFF ALASKA Pt. 679, Table 12 Table 12 to Part 679—Steller Sea Lion Protection Areas, 3nm No Groundfish Fishing Sites Steller Sea Lion Protection Areas, 3nm No Groundfish Fishing Sites...

  2. 76 FR 50212 - Site-Wide Environmental Impact Statement for Sandia National Laboratories, New Mexico (SNL/NM)

    Science.gov (United States)

    2011-08-12

    ... Environmental Impact Statement for Sandia National Laboratories, New Mexico (DOE/EIS-0281-SA-04), DOE/NNSA... Environmental Impact Statement for Sandia National Laboratories, New Mexico for the Installation of a Petawatt..., New Mexico Final Supplement Analysis for the Site-Wide Environmental Impact Statement (2006 SNL/NM...

  3. Simultaneous Ka-Band Site Characterization: Goldstone, CA, White Sands, NM, and Guam, USA

    Science.gov (United States)

    Acosta, Roberto; Morse, Jacquelynne; Zemba, Michael; Nessel, James; Morabito, David; Caroglanian, Armen

    2011-01-01

    To statistically characterize atmospheric effects on Ka-band links at NASA operational sites, NASA has constructed site test interferometers (STI s) which directly measure the tropospheric phase stability and rain attenuation. These instruments observe an unmodulated beacon signal broadcast from a geostationary satellite (e.g., Anik F2) and measure the phase difference between the signals received by the two antennas and its signal attenuation. Three STI s have been deployed so far: the first one at the NASA Deep Space Network Tracking Complex in Goldstone, California (May 2007); the second at the NASA White Sands Complex, in Las Cruses, New Mexico (February 2009); and the third at the NASA Tracking and Data Relay Satellite (TDRS) Remote Ground Terminal (GRGT) complex in Guam (May 2010). Two station-years of simultaneous atmospheric phase fluctuation data have been collected at Goldstone and White Sands, while one year of data has been collected in Guam. With identical instruments operating simultaneously, we can directly compare the phase stability and rain attenuation at the three sites. Phase stability is analyzed statistically in terms of the root-mean-square (rms) of the tropospheric induced time delay fluctuations over 10 minute blocks. For two years, the time delay fluctuations at the DSN site in Goldstone, CA, have been better than 2.5 picoseconds (ps) for 90% of the time (with reference to zenith), meanwhile at the White Sands, New Mexico site, the time delay fluctuations have been better than 2.2 ps with reference to zenith) for 90% of time. For Guam, the time delay fluctuations have been better than 12 ps (reference to zenith) at 90% of the time, the higher fluctuations are as expected from a high humidity tropical rain zone. This type of data analysis, as well as many other site quality characteristics (e.g., rain attenuation, infrastructure, etc.) will be used to determine the suitability of all the sites for NASA s future communication services at Ka-band.

  4. Site selection and evaluation studies of the Waste Isolation Pilot Plant (WIPP), Los Medanos, Eddy County, NM

    International Nuclear Information System (INIS)

    Griswold, G.B.

    1977-12-01

    Bedded-salt deposits of the Salado Formation have been selected for evaluation for a proposed Waste Isolation Pilot Plant (WIPP) to be located in Eddy County, NM, approximately 26 mi east of Carlsbad. Site selection and evaluation studies that included geologic mapping, geophysical surveys, drilling, and resource appraisal were conducted over and under the prospective location. The lower portion of the Salado meets essential criteria for waste isolation. Beds chosen for waste storage lie 2074 to 2730 ft below the surface. High-purity salt exists at these depths, and the geologic structure revealed by geophysical surveys indicates that these beds are essentially flat. Additional geophysical surveys are now under way. The initial interpretation of the new data indicates that more structure may exist in the salt beds in the northern portion of the site area. Full evaluation of potentially commercial deposits of potash and natural gas within the WIPP site will be reported by separate studies, as will be the hydrologic details of the region

  5. Fluorometric titration approach for calibration of quantity of binding site of purified monoclonal antibody recognizing epitope/hapten nonfluorescent at 340 nm.

    Science.gov (United States)

    Yang, Xiaolan; Hu, Xiaolei; Xu, Bangtian; Wang, Xin; Qin, Jialin; He, Chenxiong; Xie, Yanling; Li, Yuanli; Liu, Lin; Liao, Fei

    2014-06-17

    A fluorometric titration approach was proposed for the calibration of the quantity of monoclonal antibody (mcAb) via the quench of fluorescence of tryptophan residues. It applied to purified mcAbs recognizing tryptophan-deficient epitopes, haptens nonfluorescent at 340 nm under the excitation at 280 nm, or fluorescent haptens bearing excitation valleys nearby 280 nm and excitation peaks nearby 340 nm to serve as Förster-resonance-energy-transfer (FRET) acceptors of tryptophan. Titration probes were epitopes/haptens themselves or conjugates of nonfluorescent haptens or tryptophan-deficient epitopes with FRET acceptors of tryptophan. Under the excitation at 280 nm, titration curves were recorded as fluorescence specific for the FRET acceptors or for mcAbs at 340 nm. To quantify the binding site of a mcAb, a universal model considering both static and dynamic quench by either type of probes was proposed for fitting to the titration curve. This was easy for fitting to fluorescence specific for the FRET acceptors but encountered nonconvergence for fitting to fluorescence of mcAbs at 340 nm. As a solution, (a) the maximum of the absolute values of first-order derivatives of a titration curve as fluorescence at 340 nm was estimated from the best-fit model for a probe level of zero, and (b) molar quantity of the binding site of the mcAb was estimated via consecutive fitting to the same titration curve by utilizing such a maximum as an approximate of the slope for linear response of fluorescence at 340 nm to quantities of the mcAb. This fluorometric titration approach was proved effective with one mcAb for six-histidine and another for penicillin G.

  6. 207-nm UV light - a promising tool for safe low-cost reduction of surgical site infections. I: in vitro studies.

    Directory of Open Access Journals (Sweden)

    Manuela Buonanno

    Full Text Available BACKGROUND: 0.5% to 10% of clean surgeries result in surgical-site infections, and attempts to reduce this rate have had limited success. Germicidal UV lamps, with a broad wavelength spectrum from 200 to 400 nm are an effective bactericidal option against drug-resistant and drug-sensitive bacteria, but represent a health hazard to patient and staff. By contrast, because of its limited penetration, ~200 nm far-UVC light is predicted to be effective in killing bacteria, but without the human health hazards to skin and eyes associated with conventional germicidal UV exposure. AIMS: The aim of this work was to test the biophysically-based hypothesis that ~200 nm UV light is significantly cytotoxic to bacteria, but minimally cytotoxic or mutagenic to human cells either isolated or within tissues. METHODS: A Kr-Br excimer lamp was used, which produces 207-nm UV light, with a filter to remove higher-wavelength components. Comparisons were made with results from a conventional broad spectrum 254-nm UV germicidal lamp. First, cell inactivation vs. UV fluence data were generated for methicillin-resistant S. aureus (MRSA bacteria and also for normal human fibroblasts. Second, yields of the main UV-associated pre-mutagenic DNA lesions (cyclobutane pyrimidine dimers and 6-4 photoproducts were measured, for both UV radiations incident on 3-D human skin tissue. RESULTS: We found that 207-nm UV light kills MRSA efficiently but, unlike conventional germicidal UV lamps, produces little cell killing in human cells. In a 3-D human skin model, 207-nm UV light produced almost no pre-mutagenic UV-associated DNA lesions, in contrast to significant yields induced by a conventional germicidal UV lamp. CONCLUSIONS: As predicted based on biophysical considerations, 207-nm light kills bacteria efficiently but does not appear to be significantly cytotoxic or mutagenic to human cells. Used appropriately, 207-nm light may have the potential for safely and inexpensively

  7. 207-nm UV light - a promising tool for safe low-cost reduction of surgical site infections. I: in vitro studies.

    Science.gov (United States)

    Buonanno, Manuela; Randers-Pehrson, Gerhard; Bigelow, Alan W; Trivedi, Sheetal; Lowy, Franklin D; Spotnitz, Henry M; Hammer, Scott M; Brenner, David J

    2013-01-01

    0.5% to 10% of clean surgeries result in surgical-site infections, and attempts to reduce this rate have had limited success. Germicidal UV lamps, with a broad wavelength spectrum from 200 to 400 nm are an effective bactericidal option against drug-resistant and drug-sensitive bacteria, but represent a health hazard to patient and staff. By contrast, because of its limited penetration, ~200 nm far-UVC light is predicted to be effective in killing bacteria, but without the human health hazards to skin and eyes associated with conventional germicidal UV exposure. The aim of this work was to test the biophysically-based hypothesis that ~200 nm UV light is significantly cytotoxic to bacteria, but minimally cytotoxic or mutagenic to human cells either isolated or within tissues. A Kr-Br excimer lamp was used, which produces 207-nm UV light, with a filter to remove higher-wavelength components. Comparisons were made with results from a conventional broad spectrum 254-nm UV germicidal lamp. First, cell inactivation vs. UV fluence data were generated for methicillin-resistant S. aureus (MRSA) bacteria and also for normal human fibroblasts. Second, yields of the main UV-associated pre-mutagenic DNA lesions (cyclobutane pyrimidine dimers and 6-4 photoproducts) were measured, for both UV radiations incident on 3-D human skin tissue. We found that 207-nm UV light kills MRSA efficiently but, unlike conventional germicidal UV lamps, produces little cell killing in human cells. In a 3-D human skin model, 207-nm UV light produced almost no pre-mutagenic UV-associated DNA lesions, in contrast to significant yields induced by a conventional germicidal UV lamp. As predicted based on biophysical considerations, 207-nm light kills bacteria efficiently but does not appear to be significantly cytotoxic or mutagenic to human cells. Used appropriately, 207-nm light may have the potential for safely and inexpensively reducing surgical-site infection rates, including those of drug

  8. Interpretation of stable isotope, denitrification, and groundwater age data for samples collected from Sandia National Laboratories /New Mexico (SNL/NM) Burn Site Groundwater Area of Concern

    Energy Technology Data Exchange (ETDEWEB)

    Madrid, V. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Singleton, M. J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Visser, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Esser, B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-06-02

    This report combines and summarizes results for two groundwater-sampling events (October 2012 and October/November 2015) from the Sandia National Laboratories/New Mexico (SNL/NM) Burn Site Groundwater (BSG) Area of Concern (AOC) located in the Lurance Canyon Arroyo southeast of Albuquerque, NM in the Manzanita Mountains. The first phase of groundwater sampling occurred in October 2012 including samples from 19 wells at three separate sites that were analyzed by the Environmental Radiochemistry Laboratory at Lawrence Livermore National Laboratory as part of a nitrate Monitored Natural Attenuation (MNA) evaluation. The three sites (BSG, Technical Area-V, and Tijeras Arroyo) are shown on the regional hydrogeologic map and described in the Sandia Annual Groundwater Monitoring Report. The first phase of groundwater sampling included six monitoring wells at the Burn Site, eight monitoring wells at Technical Area-V, and five monitoring wells at Tijeras Arroyo. Each groundwater sample was analyzed using the two specialized analytical methods, age-dating and denitrification suites. In September 2015, a second phase of groundwater sampling took place at the Burn Site including 10 wells sampled and analyzed by the same two analytical suites. Five of the six wells sampled in 2012 were resampled in 2015. This report summarizes results from two sampling events in order to evaluate evidence for in situ denitrification, the average age of the groundwater, and the extent of recent recharge of the bedrock fracture system beneath the BSG AOC.

  9. Interpretation of stable isotope, denitrification, and groundwater age data for samples collected from Sandia National Laboratories /New Mexico (SNL/NM) Burn Site Groundwater Area of Concern

    International Nuclear Information System (INIS)

    Madrid, V.; Singleton, M. J.; Visser, A.; Esser, B.

    2016-01-01

    This report combines and summarizes results for two groundwater-sampling events (October 2012 and October/November 2015) from the Sandia National Laboratories/New Mexico (SNL/NM) Burn Site Groundwater (BSG) Area of Concern (AOC) located in the Lurance Canyon Arroyo southeast of Albuquerque, NM in the Manzanita Mountains. The first phase of groundwater sampling occurred in October 2012 including samples from 19 wells at three separate sites that were analyzed by the Environmental Radiochemistry Laboratory at Lawrence Livermore National Laboratory as part of a nitrate Monitored Natural Attenuation (MNA) evaluation. The three sites (BSG, Technical Area-V, and Tijeras Arroyo) are shown on the regional hydrogeologic map and described in the Sandia Annual Groundwater Monitoring Report. The first phase of groundwater sampling included six monitoring wells at the Burn Site, eight monitoring wells at Technical Area-V, and five monitoring wells at Tijeras Arroyo. Each groundwater sample was analyzed using the two specialized analytical methods, age-dating and denitrification suites. In September 2015, a second phase of groundwater sampling took place at the Burn Site including 10 wells sampled and analyzed by the same two analytical suites. Five of the six wells sampled in 2012 were resampled in 2015. This report summarizes results from two sampling events in order to evaluate evidence for in situ denitrification, the average age of the groundwater, and the extent of recent recharge of the bedrock fracture system beneath the BSG AOC.

  10. Study of atmospheric scattering and absorbing aerosols at 550 nm over nearby western Indian tropical sites of Thar Desert effected region

    International Nuclear Information System (INIS)

    Vyas, B. M.; Saxenna, Abhishek; Panwar, Chhagan

    2016-01-01

    The first time experimental results based on spaced satellite observations of different kinds of aerosols properties have been described over two different contrast environmental conditions locations in western tropical Indian region specifically first at Jaisalmer (26.90°N, 69.90°E, 220 m above mean sea level (amsl)) located in central Thar dessert vicinity of western Indian site over Indian Thar Desert region and another at Udaipur (24.6° N, 73.7° E, 560 m amsl) site concerning to semi-urban and semi arid place of hilly areas. The daily values of aerosols optical depth absorption at 500nm (AOD abs 500nm), aerosols optical depth extinction at 500nm (AOD ext 500nm) along with aerosols optical depth at 500nmon (AOD 500nm) of eleven year period from Jan., 2004 to Dec., 2014 are basis of primary database of the present investigation. From the synthesis if the above database and the basis of rigorous statistical approach, following some of interesting facts are noted (i) larger annual monthly AOD variation of 0.93 is noted over JSM when compared to observed annual monthly change in AOD cycle, over UDP, of only 0.50 clearly indicating the more impact of desert influence activities about more than double times over JSM than UDP (ii) The higher abundance of absorbing aerosols occurrences about two time higher are seen in JSM in comparison to UDP. It indicates the clear evidence of strong optical absorption properties of useful solar mid visible wavelength at 550nm as the results of presence of more availability of dust aerosols as mineral natural type in pre-monsoon to post-monsoon over JSM which is also more predominant over JSM than the UDP region located far away from desert activity regime (iii) The greater sharing of extinction solar radiation effect on aerosols are more effective in pre-monsoon in UDP in reference to over JSM, where as in case of UDP, the aerosols effect through the scattering mechanism gradually reduce from monsoon to winter months as compared

  11. Study of atmospheric scattering and absorbing aerosols at 550 nm over nearby western Indian tropical sites of Thar Desert effected region

    Energy Technology Data Exchange (ETDEWEB)

    Vyas, B. M., E-mail: bmvyas@yahoo.com; Saxenna, Abhishek; Panwar, Chhagan [Department of Physics, M.L. Sukhadia University, Udaipur-313001 (India)

    2016-05-06

    The first time experimental results based on spaced satellite observations of different kinds of aerosols properties have been described over two different contrast environmental conditions locations in western tropical Indian region specifically first at Jaisalmer (26.90°N, 69.90°E, 220 m above mean sea level (amsl)) located in central Thar dessert vicinity of western Indian site over Indian Thar Desert region and another at Udaipur (24.6° N, 73.7° E, 560 m amsl) site concerning to semi-urban and semi arid place of hilly areas. The daily values of aerosols optical depth absorption at 500nm (AOD abs 500nm), aerosols optical depth extinction at 500nm (AOD ext 500nm) along with aerosols optical depth at 500nmon (AOD 500nm) of eleven year period from Jan., 2004 to Dec., 2014 are basis of primary database of the present investigation. From the synthesis if the above database and the basis of rigorous statistical approach, following some of interesting facts are noted (i) larger annual monthly AOD variation of 0.93 is noted over JSM when compared to observed annual monthly change in AOD cycle, over UDP, of only 0.50 clearly indicating the more impact of desert influence activities about more than double times over JSM than UDP (ii) The higher abundance of absorbing aerosols occurrences about two time higher are seen in JSM in comparison to UDP. It indicates the clear evidence of strong optical absorption properties of useful solar mid visible wavelength at 550nm as the results of presence of more availability of dust aerosols as mineral natural type in pre-monsoon to post-monsoon over JSM which is also more predominant over JSM than the UDP region located far away from desert activity regime (iii) The greater sharing of extinction solar radiation effect on aerosols are more effective in pre-monsoon in UDP in reference to over JSM, where as in case of UDP, the aerosols effect through the scattering mechanism gradually reduce from monsoon to winter months as compared

  12. Size distributions of non-volatile particle residuals (Dp<800 nm at a rural site in Germany and relation to air mass origin

    Directory of Open Access Journals (Sweden)

    T. Tuch

    2007-11-01

    Full Text Available Atmospheric aerosol particle size distributions at a continental background site in Eastern Germany were examined for a one-year period. Particles were classified using a twin differential mobility particle sizer in a size range between 3 and 800 nm. As a novelty, every second measurement of this experiment involved the removal of volatile chemical compounds in a thermodenuder at 300°C. This concept allowed to quantify the number size distribution of non-volatile particle cores – primarily associated with elemental carbon, and to compare this to the original non-conditioned size distribution. As a byproduct of the volatility analysis, new particles originating from nucleation inside the thermodenuder can be observed, however, overwhelmingly at diameters below 6 nm. Within the measurement uncertainty, every particle down to particle sizes of 15 nm is concluded to contain a non-volatile core. The volume fraction of non-volatile particulate matter (non-conditioned diameter < 800 nm varied between 10 and 30% and was largely consistent with the experimentally determined mass fraction of elemental carbon. The average size of the non-volatile particle cores was estimated as a function of original non-conditioned size using a summation method, which showed that larger particles (>200 nm contained more non-volatile compounds than smaller particles (<50 nm, thus indicating a significantly different chemical composition. Two alternative air mass classification schemes based on either, synoptic chart analysis (Berliner Wetterkarte or back trajectories showed that the volume and number fraction of non-volatile cores depended less on air mass than the total particle number concentration. In all air masses, the non-volatile size distributions showed a more and a less volatile ("soot" mode, the latter being located at about 50 nm. During unstable conditions and in maritime air masses, smaller values were observed compared to stable or continental conditions

  13. Real-time soft error rate measurements on bulk 40 nm SRAM memories: a five-year dual-site experiment

    Science.gov (United States)

    Autran, J. L.; Munteanu, D.; Moindjie, S.; Saad Saoud, T.; Gasiot, G.; Roche, P.

    2016-11-01

    This paper reports five years of real-time soft error rate experimentation conducted with the same setup at mountain altitude for three years and then at sea level for two years. More than 7 Gbit of SRAM memories manufactured in CMOS bulk 40 nm technology have been subjected to the natural radiation background. The intensity of the atmospheric neutron flux has been continuously measured on site during these experiments using dedicated neutron monitors. As the result, the neutron and alpha component of the soft error rate (SER) have been very accurately extracted from these measurements, refining the first SER estimations performed in 2012 for this SRAM technology. Data obtained at sea level evidence, for the first time, a possible correlation between the neutron flux changes induced by the daily atmospheric pressure variations and the measured SER. Finally, all of the experimental data are compared with results obtained from accelerated tests and numerical simulation.

  14. 207-nm UV Light-A Promising Tool for Safe Low-Cost Reduction of Surgical Site Infections. II: In-Vivo Safety Studies.

    Science.gov (United States)

    Buonanno, Manuela; Stanislauskas, Milda; Ponnaiya, Brian; Bigelow, Alan W; Randers-Pehrson, Gerhard; Xu, Yanping; Shuryak, Igor; Smilenov, Lubomir; Owens, David M; Brenner, David J

    2016-01-01

    UVC light generated by conventional germicidal lamps is a well-established anti-microbial modality, effective against both bacteria and viruses. However, it is a human health hazard, being both carcinogenic and cataractogenic. Earlier studies showed that single-wavelength far-UVC light (207 nm) generated by excimer lamps kills bacteria without apparent harm to human skin tissue in vitro. The biophysical explanation is that, due to its extremely short range in biological material, 207 nm UV light cannot penetrate the human stratum corneum (the outer dead-cell skin layer, thickness 5-20 μm) nor even the cytoplasm of individual human cells. By contrast, 207 nm UV light can penetrate bacteria and viruses because these cells are physically much smaller. To test the biophysically-based hypothesis that 207 nm UV light is not cytotoxic to exposed mammalian skin in vivo. Hairless mice were exposed to a bactericidal UV fluence of 157 mJ/cm2 delivered by a filtered Kr-Br excimer lamp producing monoenergetic 207-nm UV light, or delivered by a conventional 254-nm UV germicidal lamp. Sham irradiations constituted the negative control. Eight relevant cellular and molecular damage endpoints including epidermal hyperplasia, pre-mutagenic UV-associated DNA lesions, skin inflammation, and normal cell proliferation and differentiation were evaluated in mice dorsal skin harvested 48 h after UV exposure. While conventional germicidal UV (254 nm) exposure produced significant effects for all the studied skin damage endpoints, the same fluence of 207 nm UV light produced results that were not statistically distinguishable from the zero exposure controls. As predicted by biophysical considerations and in agreement with earlier in vitro studies, 207-nm light does not appear to be significantly cytotoxic to mouse skin. These results suggest that excimer-based far-UVC light could potentially be used for its anti-microbial properties, but without the associated hazards to skin of conventional

  15. 207-nm UV Light—A Promising Tool for Safe Low-Cost Reduction of Surgical Site Infections. II: In-Vivo Safety Studies

    Science.gov (United States)

    Buonanno, Manuela; Stanislauskas, Milda; Ponnaiya, Brian; Bigelow, Alan W.; Randers-Pehrson, Gerhard; Xu, Yanping; Shuryak, Igor; Smilenov, Lubomir; Owens, David M.; Brenner, David J.

    2016-01-01

    Background UVC light generated by conventional germicidal lamps is a well-established anti-microbial modality, effective against both bacteria and viruses. However, it is a human health hazard, being both carcinogenic and cataractogenic. Earlier studies showed that single-wavelength far-UVC light (207 nm) generated by excimer lamps kills bacteria without apparent harm to human skin tissue in vitro. The biophysical explanation is that, due to its extremely short range in biological material, 207 nm UV light cannot penetrate the human stratum corneum (the outer dead-cell skin layer, thickness 5–20 μm) nor even the cytoplasm of individual human cells. By contrast, 207 nm UV light can penetrate bacteria and viruses because these cells are physically much smaller. Aims To test the biophysically-based hypothesis that 207 nm UV light is not cytotoxic to exposed mammalian skin in vivo. Methods Hairless mice were exposed to a bactericidal UV fluence of 157 mJ/cm2 delivered by a filtered Kr-Br excimer lamp producing monoenergetic 207-nm UV light, or delivered by a conventional 254-nm UV germicidal lamp. Sham irradiations constituted the negative control. Eight relevant cellular and molecular damage endpoints including epidermal hyperplasia, pre-mutagenic UV-associated DNA lesions, skin inflammation, and normal cell proliferation and differentiation were evaluated in mice dorsal skin harvested 48 h after UV exposure. Results While conventional germicidal UV (254 nm) exposure produced significant effects for all the studied skin damage endpoints, the same fluence of 207 nm UV light produced results that were not statistically distinguishable from the zero exposure controls. Conclusions As predicted by biophysical considerations and in agreement with earlier in vitro studies, 207-nm light does not appear to be significantly cytotoxic to mouse skin. These results suggest that excimer-based far-UVC light could potentially be used for its anti-microbial properties, but without

  16. Environmental Assessment for Leasing Land for the Siting, Construction and Operation of a Commercial AM Radio Antenna at Los Alamos National Laboratory, Los Alamos, NM

    Energy Technology Data Exchange (ETDEWEB)

    N/A

    2000-02-16

    The United States (U.S.) Department of Energy (DOE) proposes to lease approximately 3 acres of land at the Los Alamos National Laboratory (LANL) on the southeast tip of Technical Area (TA) 54 for the siting, construction and operation of an AM radio broadcasting antenna. This Environmental Assessment (EA) has been developed in order to assess the environmental effects of the Proposed Action and No Action alternative. The Proposed Action includes the lease of land for the siting, construction and operation of an AM radio broadcasting antenna in TA-54, just north of Pajarito Road and State Highway 4. The No Action Alternative was also considered. Under the No Action Alternative, DOE would not lease land on LANL property for the siting and operation of an AM radio broadcasting antenna; the DOE would not have a local station for emergency response use; and the land would continue to be covered in native vegetation and serve as a health and safety buffer zone for TA-54 waste management activities. Other potential sites on LANL property were evaluated but dismissed for reasons such as interference with sensitive laboratory experiments. Potential visual, health, and environmental effects are anticipated to be minimal for the Proposed Action. The radio broadcasting antenna would be visible against the skyline from some public areas, but would be consistent with other man-made objects in the vicinity that partially obstruct viewsheds (e.g. meteorological tower, power lines). Therefore, the net result would be a modest change of the existing view. Electromagnetic field (EMF) emissions from the antenna would be orders or magnitude less than permissible limits. The proposed antenna construction would not affect known cultural sites, but is located in close proximity to two archaeological sites. Construction would be monitored to ensure that the associated road and utility corridor would avoid cultural sites.

  17. Stable isotopic study of soil water from the WIPP site: Constraints on the origin of water in the Rustler Fm, Delaware Basin, NM

    International Nuclear Information System (INIS)

    Campbell, A.R.; Vanlandingham, R.J.; Phillips, F.M.

    1992-01-01

    The Rustler Fm. overlies the salt beds in Salado Fm. in which the Waste Isolation Pilot Plant is being developed. The water in the Rustler Fm. aquifers have been the subject of various studies, including stable isotopes. Lambert and Harvey note that the Rustler waters all have δD below -43% whereas the other young ground waters in the region have δD's above 41%. They conclude that the water in the Rustler is not from modern recharge but is fossil water from a past climatic regime. Chapman on the other hand concludes that waters on Carlsbad Caverns are isotopically heavier than the Rustler water due to cave evaporation, and thus the Rustler water could be from modern recharge. The two different interpretations have very different implications for the hydrological characterization of the WIPP site. In order to further study this issue the authors have collected six shallow cores from the unconsolidated sand in the vicinity of WIPP. Water was extracted from each sample by vacuum distillation. For these samples the projected meteoric waters would have δD values in the range of -45 to -55%. This falls well within the range of the δD values for the Rustler Fm. From this the author concludes that the Rustler water could result from modern precipitation, although not from infiltration through a soil where evaporation is active. Soil waters may provide important isotopic constraints on the origins of water in regional aquifer systems

  18. Reports on 1977 result of research. Investigation for selecting site location of pilot plant for 7,000Nm{sup 3}/day class high calorie gasification; 1977 nendo sunshine keikaku ni kakawaru plant kenkyu kaihatsu seika hokoku. 7,000Nm{sup 3}/nichi kyu kokarori gas ka pilot plant yochi no ricchi sentei chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1978-03-20

    A report was made on the result of investigation for selecting a suitable site for a coal gasification pilot plant. The high calorie gasification plant under the Sunshine Project is scheduled to have a parallel operation of two methods. It could be decided on one only method depending on the future studies. One is the 'water gasification method' using coal only as the raw material, with hydrogen gas added to contrive methanization. The other is the 'hybrid gasification method' using mixed slurry of powdered coal and heavy oil as the raw material, with oxygen supplied to it to form a clean gas. The sites proposed for the pilot plant are the cities of Yubari, Iwaki, Kita-Ibaraki, Tagawa, Iizuka and Imari. The items for assessment of cost effectiveness are the expenses of development of a site, road construction, removal of existing obstacles, plant construction, power receiving equipment construction, irrigation supply facilities construction, wastewater treatment system construction, ash discharging system construction, transportation, and supply/processing-related maintenance. As a result of the assessment, Iwaki city was picked up as the area almost free from drawbacks to cost effectiveness. (NEDO)

  19. Reports on 1977 result of research. Investigation for selecting site location of pilot plant for 7,000Nm{sup 3}/day class high calorie gasification; 1977 nendo sunshine keikaku ni kakawaru plant kenkyu kaihatsu seika hokoku. 7,000Nm{sup 3}/nichi kyu kokarori gas ka pilot plant yochi no ricchi sentei chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1978-03-20

    A report was made on the result of investigation for selecting a suitable site for a coal gasification pilot plant. The high calorie gasification plant under the Sunshine Project is scheduled to have a parallel operation of two methods. It could be decided on one only method depending on the future studies. One is the 'water gasification method' using coal only as the raw material, with hydrogen gas added to contrive methanization. The other is the 'hybrid gasification method' using mixed slurry of powdered coal and heavy oil as the raw material, with oxygen supplied to it to form a clean gas. The sites proposed for the pilot plant are the cities of Yubari, Iwaki, Kita-Ibaraki, Tagawa, Iizuka and Imari. The items for assessment of cost effectiveness are the expenses of development of a site, road construction, removal of existing obstacles, plant construction, power receiving equipment construction, irrigation supply facilities construction, wastewater treatment system construction, ash discharging system construction, transportation, and supply/processing-related maintenance. As a result of the assessment, Iwaki city was picked up as the area almost free from drawbacks to cost effectiveness. (NEDO)

  20. Organic antireflective coatings for 193-nm lithography

    Science.gov (United States)

    Trefonas, Peter, III; Blacksmith, Robert F.; Szmanda, Charles R.; Kavanagh, Robert J.; Adams, Timothy G.; Taylor, Gary N.; Coley, Suzanne; Pohlers, Gerd

    1999-06-01

    Organic anti-reflective coatings (ARCs) continue to play an important role in semiconductor manufacturing. These materials provide a convenient means of greatly reducing the resist photospeed swing and reflective notching. In this paper, we describe a novel class of ARC materials optimized for lithographic applications using 193 nm exposure tools. These ARCs are based upon polymers containing hydroxyl-alkyl methacrylate monomers for crosslinkable sites, styrene for a chromophore at 193 nm, and additional alkyl-methacrylate monomers as property modifiers. A glycouril crosslinker and a thermally-activated acidic catalyst provide a route to forming an impervious crosslinked film activate data high bake temperatures. ARC compositions can be adjusted to optimize the film's real and imaginary refractive indices. Selection of optimal target indices for 193 nm lithographic processing through simulations is described. Potential chromophores for 193 nm were explored using ZNDO modeling. We show how these theoretical studies were combined with material selection criteria to yield a versatile organic anti-reflectant film, Shipley 193 G0 ARC. Lithographic process data indicates the materials is capable of supporting high resolution patterning, with the line features displaying a sharp resist/ARC interface with low line edge roughness. The resist Eo swing is successfully reduced from 43 percent to 6 percent.

  1. 355-nm hypersensitization of optical fibers

    NARCIS (Netherlands)

    Canagasabey, A.; Canning, J.; Groothoff, N.

    2003-01-01

    A study is presented on 355-nm hypersensitization of optical fibers. It is found that the intrinsic 244-nm photosensitivity of boron-codoped germanosilicate optical fibers is enhanced by 355-nm hypersensitization. Hypersensitization through standard polymer coating is also demonstrated.

  2. Advances in 750 nm VECSELs (Conference Presentation)

    Science.gov (United States)

    Saarinen, Esa J.; Ranta, Sanna; Lyytikäinen, Jari; Saarela, Antti; Sirbu, Alexei; Iakovlev, Vladimir; Kapon, Eli; Guina, Mircea

    2017-03-01

    Lasers operating in the transmission window of tissue at wavelengths between 700 and 800 nm are needed in numerous medical and biomedical applications, including photodynamic therapy and fluorescence microscopy. However, the performance of diode lasers in this spectral range is limited by the lack of appropriate compound semiconductors. Here, we review our recent research on 750 nm VECSELs. Two approaches to reaching the 750 nm wavelength will be discussed. The first approach relies on intra-cavity frequency doubling a wafer-fused 1500 nm VECSEL. The VECSEL gain chip comprises a GaAs-based DBR and an InP-based gain section, which allows for optical pumping with low-cost commercial diodes at 980 nm. With this scheme we have achieved watt-level output powers and tuning of the laser wavelength over a 40 nm band at around 750 nm. The second approach is direct emission at 750 nm using the AlGaAs/GaAs material system. In this approach visible wavelengths are required for optical pumping. However, the consequent higher costs compared to pumping at 980 nm are mitigated by the more compact laser setup and prospects of doubling the frequency to the ultraviolet range.

  3. Hypersensitisation using 266nm Laser Light

    DEFF Research Database (Denmark)

    Sørensen, Henrik Rokkjær; Canning, John; Kristensen, Martin

    UV-hypersensitisation using 266nm VW-light on hydrogenated Ge-doped fibre is reported. The optimum fluence to be between 5 to 10 kJ/cm2, coinciding with results obtained using 355nm light, indicating same end-process in both reactions.......UV-hypersensitisation using 266nm VW-light on hydrogenated Ge-doped fibre is reported. The optimum fluence to be between 5 to 10 kJ/cm2, coinciding with results obtained using 355nm light, indicating same end-process in both reactions....

  4. Dust Explosion Characteristics of Agglomerated 35 nm and 100 nm Aluminum Particles

    Directory of Open Access Journals (Sweden)

    Hong-Chun Wu

    2010-01-01

    Full Text Available In the experiment, nanoparticles of 35 nm Al and 100 nm Al powders, respectively, formed particles with average sizes of 161 nm and 167 nm in agglomeration. The characteristics of dust cloud explosions with the two powder sizes, 35 nm and 100 nm, revealed considerable differences, as shown here: (dp/dtmax-35 nm = 1254 bar/s, (dp/dtmax-100 nm = 1105 bar/s; Pmax-35 nm = 7.5 bar, Pmax-100 nm = 12.3 bar, and MEC-35 nm = 40 g/m3, MEC-100 nm = 50 g/m3. The reason of Pmax-35 nm value is smaller than Pmax-100 nm may be due to agglomeration. From an analysis of the explosive residue, the study found that nanoparticles of 35 nm Al powder became filamentous strands after an explosion, where most of 100 nm Al nanoparticles maintained a spherical structure, This may be because the initial melting temperature of 35 nm Al is 435.71°C, while that for 100 nm Al is 523.58°C, higher by 87.87°C. This study discovered that explosive property between the 35 nm Al and 100 nm Al powders after agglomeration were different.

  5. Laser hypersensitisation using 266nm light

    DEFF Research Database (Denmark)

    Sørensen, Henrik Rokkjær; Canning, J.; Kristensen, Martin

    2005-01-01

    UV hypersensitisation using CW 266 nm light on hydrogenated Ge-doped fibre is reported. The optimum sensitisation fluence is found to be in the range of 5 to 10 kJ/cm2, coinciding with previous results obtained using 355 nm light, indicating the same end-process used in the photochemical reaction...

  6. Capillary Condensation in 8 nm Deep Channels.

    Science.gov (United States)

    Zhong, Junjie; Riordon, Jason; Zandavi, Seyed Hadi; Xu, Yi; Persad, Aaron H; Mostowfi, Farshid; Sinton, David

    2018-02-01

    Condensation on the nanoscale is essential to understand many natural and synthetic systems relevant to water, air, and energy. Despite its importance, the underlying physics of condensation initiation and propagation remain largely unknown at sub-10 nm, mainly due to the challenges of controlling and probing such small systems. Here we study the condensation of n-propane down to 8 nm confinement in a nanofluidic system, distinct from previous studies at ∼100 nm. The condensation initiates significantly earlier in the 8 nm channels, and it initiates from the entrance, in contrast to channels just 10 times larger. The condensate propagation is observed to be governed by two liquid-vapor interfaces with an interplay between film and bridging effects. We model the experimental results using classical theories and find good agreement, demonstrating that this 8 nm nonpolar fluid system can be treated as a continuum from a thermodynamic perspective, despite having only 10-20 molecular layers.

  7. Studies on nanosecond 532nm and 355nm and ultrafast 515nm and 532nm laser cutting super-hard materials

    Science.gov (United States)

    Zhang, Jie; Tao, Sha; Wang, Brian; Zhao, Jay

    2017-02-01

    In this paper, micro-processing of three kinds of super-hard materials of poly-crystal diamond (PCD)/tungsten-carbide (WC), CVD-diamond and cubic boron nitride (CNB) has been systematically studied using nanosecond laser (532nm and 355nm), and ultrafast laser (532nm and 515nm). Our purpose is to investigate a full laser micro-cutting solution to achieve a ready-to-use cutting tool insert (CTI). The results show a clean cut with little burns and recasting at edge. The cutting speed of 2-10mm/min depending on thickness was obtained. The laser ablation process was also studied by varying laser parameters (wavelength, pulse width, pulse energy, repetition rate) and tool path to improve cutting speed. Also, studies on material removal efficiency (MRE) of PCD/WC with 355nm-ns and 515nm-fs laser as a function of laser fluence show that 355nm-ns laser is able to achieve higher MRE for PCD and WC. Thus, ultrafast laser is not necessarily used for superhard material cutting. Instead, post-polishing with ultrafast laser can be used to clean cutting surface and improve smoothness.

  8. 650 nm Laser stimulated dating from Side Antique Theatre, Turkey

    International Nuclear Information System (INIS)

    Doğan, M.; Meriç, N.

    2014-01-01

    Samples were taken from the archeological excavation site, which was at the backs of the Side Antique Theatre. Samples were taken from under the base rock in this area. Polymineral fine grains were examined to determine the ages of the sediments. Samples gathered from the Side Antique Theatre were investigated through using the SAR method. Firstly, one part of the samples were evaluated by using conventional IRSL reading head model of (ELSEC-9010) which is infrared (880±80 nm) stimulation source with Schott BG39 filter. The IRSL age dating with feldspar minerals, gives a number of overestimated or underestimated age values as a result. A new reading head was proposed with the following configuration attachments for overestimation of equivalent dose rates. Measurements were done with this newly designed red laser stimulating reading head which works with Elsec 9010 OSL age dating system. SAR measurements were performed by (650±10 nm) red laser light source with two Schott BG3 filters. With usage of the new designed reading head; closer results were obtained in comparision with the Antique Theatre′s expected age range. Fading rates were taken into consideration and these corrections were also handled for true age results. - Highlights: • Polymineral fine grain feldspar minerals were used for dating. • Two different reading heads were used to determine equivalent doses. • IR stimulated (880 nm) and laser stimulated (650 nm) dating results were compared

  9. 308nm Excimer Laser in Dermatology

    Science.gov (United States)

    Mehraban, Shadi

    2014-01-01

    308nm xenon-chloride excimer laser, a novel mode of phototherapy, is an ultraviolet B radiation system consisting of a noble gas and halide. The aim of this systematic review was to investigate the literature and summarize all the experiments, clinical trials and case reports on 308-nm excimer laser in dermatological disorders. 308-nm excimer laser has currently a verified efficacy in treating skin conditions such as vitiligo, psoriasis, atopic dermatitis, alopecia areata, allergic rhinitis, folliculitis, granuloma annulare, lichen planus, mycosis fungoides, palmoplantar pustulosis, pityriasis alba, CD30+ lympho proliferative disorder, leukoderma, prurigo nodularis, localized scleroderma and genital lichen sclerosus. Although the 308-nm excimer laser appears to act as a promising treatment modality in dermatology, further large-scale studies should be undertaken in order to fully affirm its safety profile considering the potential risk, however minimal, of malignancy, it may impose. PMID:25606333

  10. PM Raman fiber laser at 1679 nm

    DEFF Research Database (Denmark)

    Svane, Ask Sebastian; Rottwitt, Karsten

    2012-01-01

    We demonstrate a PM Raman fiber laser emitting light at 1679 nm. The laser has an slope efficiency of 67 % and an output power of more than 275mWwith a 27 pm linewidth.......We demonstrate a PM Raman fiber laser emitting light at 1679 nm. The laser has an slope efficiency of 67 % and an output power of more than 275mWwith a 27 pm linewidth....

  11. 130-nm tunable grating-mirror VCSEL

    DEFF Research Database (Denmark)

    Chung, Il-Sug; Mørk, Jesper

    2014-01-01

    configuration instead of the extended cavity configuration can bring 130-nm tuning range around 1330-nm wavelength. The air-coupled cavity is known to reduce the quantum confinement factor in VCSELs, increasing threshold. In our air-coupled cavity HCG VCSEL case, the very short power penetration length...... in the HCG minimizes this reduction of the quantum confinement factor, not as significant as in the air-coupled cavity DBR VCSEL....

  12. Radiation Failures in Intel 14nm Microprocessors

    Science.gov (United States)

    Bossev, Dobrin P.; Duncan, Adam R.; Gadlage, Matthew J.; Roach, Austin H.; Kay, Matthew J.; Szabo, Carl; Berger, Tammy J.; York, Darin A.; Williams, Aaron; LaBel, K.; hide

    2016-01-01

    In this study the 14 nm Intel Broadwell 5th generation core series 5005U-i3 and 5200U-i5 was mounted on Dell Inspiron laptops, MSI Cubi and Gigabyte Brix barebones and tested with Windows 8 and CentOS7 at idle. Heavy-ion-induced hard- and catastrophic failures do not appear to be related to the Intel 14nm Tri-Gate FinFET process. They originate from a small (9 m 140 m) area on the 32nm planar PCH die (not the CPU) as initially speculated. The hard failures seem to be due to a SEE but the exact physical mechanism has yet to be identified. Some possibilities include latch-ups, charge ion trapping or implantation, ion channels, or a combination of those (in biased conditions). The mechanism of the catastrophic failures seems related to the presence of electric power (1.05V core voltage). The 1064 nm laser mimics ionization radiation and induces soft- and hard failures as a direct result of electron-hole pair production, not heat. The 14nm FinFET processes continue to look promising for space radiation environments.

  13. Diode laser (980nm) cartilage reshaping

    Science.gov (United States)

    El Kharbotly, A.; El Tayeb, T.; Mostafa, Y.; Hesham, I.

    2011-03-01

    Loss of facial or ear cartilage due to trauma or surgery is a major challenge to the otolaryngologists and plastic surgeons as the complicated geometric contours are difficult to be animated. Diode laser (980 nm) has been proven effective in reshaping and maintaining the new geometric shape achieved by laser. This study focused on determining the optimum laser parameters needed for cartilage reshaping with a controlled water cooling system. Harvested animal cartilages were angulated with different degrees and irradiated with different diode laser powers (980nm, 4x8mm spot size). The cartilage specimens were maintained in a deformation angle for two hours after irradiation then released for another two hours. They were serially measured and photographed. High-power Diode laser irradiation with water cooling is a cheep and effective method for reshaping the cartilage needed for reconstruction of difficult situations in otorhinolaryngologic surgery. Key words: cartilage,diode laser (980nm), reshaping.

  14. Liquid Carbon Reflectivity at 19 nm

    Directory of Open Access Journals (Sweden)

    Riccardo Mincigrucci

    2015-01-01

    Full Text Available We hereby report on a pump-probe reflectivity experiment conducted on amorphous carbon, using a 780 nm laser as a pump and a 19 nm FEL emission as probe. Measurements were performed at 50 degrees with respect to the surface normal to have an un-pumped reflectivity higher than 0.5%. A sub-10 fs time synchronization error could be obtained exploiting the nearly jitter-free capabilities of FERMI. EUV FEL-based experiments open the way to study the behaviour of a liquid carbon phase being unaffected by plasma screening.

  15. Design of an 1800nm Raman amplifier

    DEFF Research Database (Denmark)

    Svane, Ask Sebastian; Rottwitt, Karsten

    2013-01-01

    We present the experimental results for a Raman amplifier that operates at 1810 nm and is pumped by a Raman fiber laser at 1680 nm. Both the pump laser and the Raman amplifier is polarization maintaining. A challenge when scaling Raman amplifiers to longer wavelengths is the increase...... in transmission loss, but also the reduction in the Raman gain coefficient as the amplifier wavelength is increased. Both polarization components of the Raman gain is characterized, initially for linearly co-polarized signal and pump, subsequently linearly polarized orthogonal signal and pump. The noise...

  16. Super ACO FEL oscillation at 300 nm

    CERN Document Server

    Nutarelli, D; Renault, E; Nahon, L; Couprie, Marie Emmanuelle

    2000-01-01

    Some recent improvements, involving both the optical cavity mirrors and the positron beam dynamics in the storage ring, have allowed us to achieve a laser oscillation at 300 nm on the Super ACO Storage Ring FEL. The Super ACO storage ring is operated at 800 MeV which is the nominal energy for the usual synchrotron radiation users, and the highest energy for a storage ring FEL. The lasing at 300 nm could be kept during 2 h per injection, with a stored current ranging between 30 and 60 mA. The FEL characteristics are presented here. The longitudinal stability and the FEL optics behaviour are also discussed.

  17. Photoelectron Emission Studies in CsBr at 257 nm

    International Nuclear Information System (INIS)

    Maldonado, Juan R.; Liu, Zhi; Sun, Yun; Pianetta, Piero A.; Pease, Fabian W.

    2006-01-01

    CsBr/Cr photocathodes were found [1,2] to meet the requirements of a multi-electron beam lithography system operating with a light energy of 4.8 eV (257nm). The fact that photoemission was observed with a light energy below the reported 7.3 eV band gap for CsBr was not understood. This paper presents experimental results on the presence of intra-band gap absorption sites (IBAS) in CsBr thin film photo electron emitters, and presents a model based on IBAS to explain the observed photoelectron emission behavior at energies below band gap. A fluorescence band centered at 330 nm with a FWHM of about 0.34 eV was observed in CsBr/Cr samples under 257 nm laser illumination which can be attributed to IBAS and agrees well with previously obtained synchrotron photoelectron spectra[1] from the valence band of CsBr films

  18. Alveolar macrophage accumulation rates, for 28 nm and 250 nm PSL, are mediated by separate mechanisms

    Energy Technology Data Exchange (ETDEWEB)

    Moss, O R; Wong, V A, E-mail: moss@thehamner.or [Hamner Institutes for Health Sciences, Research Triangle Park, NC 27509-2137 (United States)

    2009-02-01

    When macrophages accumulate 28 nm and 250 nm diameter polystyrene latex (PSL) beads, the accumulation rates should reflect differences in molecular and cellular function. We used a confocal microscope to measure the accumulation rates of nanoparticles by F344-rat-alveolar macrophages (approx25,000 cells adhered to a 0.7 cm{sup 2} surface). Over the cells were layered 0.1 ml of media, and 0.1 ml of media-with-beads. Fresh cells were introduced for each exposure scenario. The maximum possible individual macrophage exposures were as follows: 8x10{sup 6}, 8x10{sup 5}, and 8x10{sup 4} 28 nm beads per macrophage; and 8x10{sup 4} and 1.12x10{sup 4} 250 nm beads per macrophage. Accumulation rates were estimated over 23 minutes. The increase in bead accumulation-rate matched changes in bead-availability: 7x increase for 250 nm beads; 100x increase for 28 nm beads; and 700x increase for all bead availabilities. The maximum sustained 28 nm bead accumulation rate was > 30,000 /min (for 5 min). Increases in bead accumulation could be explained by two mechanisms: bead-diffusion; and, for the macrophage, macropinocytosis. Also for the highest concentrations of 28 nm beads, we saw a colligative threshold - possibly due to beads masking the cell surface or obstructing cellular mechanisms.

  19. Repair of near-UV (365nm or 313 nm) induced DNA strand breaks

    International Nuclear Information System (INIS)

    Miguel, A.G.

    1981-01-01

    The action of near-UV (365 nm or 313 nm) radiation in cellular inactivaton (biological measurements) and induction and repair of breaks (physical measurements) is studied in repair proficient strain and in pol A, rec A and uvr A deficient strains of Escherichia coli K-12. (M.A.C.) [pt

  20. All-dry resist processes for 193-nm lithography

    Science.gov (United States)

    Horn, Mark W.; Maxwell, Brian E.; Kunz, Roderick R.; Hibbs, Michael S.; Eriksen, Lynn M.; Palmateer, Susan C.; Forte, Anthony R.

    1995-06-01

    We report on two different all-dry resist schemes for 193-nm lithography, one negative tone and one positive tone. Our negative tone resist is an extension of our initial work on all-dry photoresists. This scheme employs a bilayer in which the imaging layer is formed by plasma enhanced chemical vapor deposition (PECVD) from tetramethylsilane (TMS) and deposited onto PECVD carbon-based planarizing layers. Figure 1 shows SEMs of dark field and light field octagons patterned in projection on Lincoln Laboratory's 0.5-NA 193-nm Micrascan system. These 0.225-micrometers and 0.200-micrometers line and space features were obtained at a dose of approximately 58 mJ/cm2. Dry development of the exposed resist was accomplished using Cl2 chemistry in a helicon high-ion-density etching tool. Pattern transfer was performed in the helicon tool with oxygen-based chemistries. Recently, we have also developed an all-dry positive-tone silylation photoresist. This photoresist is a PECVD carbon-based polymer which is crosslinked by 193-nm exposure, enabling selective silylation similar to that initially reported by Hartney et al., with spin-applied polymers. In those polymers, for example polyvinylphenol, the silylation site concentration is fixed by the hydroxyl groups on the polymer precursors, thus limiting the silicon uptake per unit volume. With PECVD polymers, the total concentration of silylation sites and their depth can be tailored by varying plasma species as a function of time during the deposition. This affords the possibility of greater silicon uptake per unit volume and better depth control of the silylation profile. Figure 2 shows a SEM of 0.5-micrometers features patterned in plasma deposited silylation resist.

  1. Photochemistry of acrylates at 222 nm

    International Nuclear Information System (INIS)

    Knolle, Wolfgang; Naumov, Sergej; Madani, Mohamed; Sonntag, Clemens von

    2005-01-01

    Excimer lamps as monochromatic UV sources with an intense short-wavelength emission (especially KrCl * , 222 nm) allow a photoinitiator-free initiation of the acrylate polymerisation. Laser photolysis (KrCl * excimer laser, pulse width 20 ns, up to 5 mJ per pulse) gives rise to similar transient spectra (λ max ∼ 280 nm) for all acrylates studied. As the rather unspecific spectra do not allow conclusions as to the main reaction channel, a product study has been performed by GC-MS following steady-state photolysis of acrylate solutions in acetonitrile, methanol and n-hexane. Somewhat unexpected, α-cleavage seems to be a main reaction channel, and quantum chemical calculations show that such a reaction can occur from either the excited singlet state or the unrelaxed triplet state, but not from the relaxed triplet state that is observed spectroscopically. A reaction scheme accounting for the observed products is presented

  2. Design of Polymer Wavelength Splitter 1310 nm/1550 nm Based on Multimode Interferences

    Directory of Open Access Journals (Sweden)

    V. Prajzler

    2010-12-01

    Full Text Available We report about design of 1x2 1310/1550 nm optical wavelength division multiplexer based on polymer waveguides. The polymer splitter was designed by using RSoft software based on beam propagation method. Epoxy novolak resin polymer was used as core waveguides layer, silicon substrate with silica layer was used as buffer layer and polymethylmethacrylate was used as protection cover layer. The simulation shows that the output energy for the fundamental mode is 67.1 % for 1310 nm and 67.8 % for 1550 nm wavelength.

  3. Passively mode-locked Nd:YVO4 laser operating at 1073 nm and 1085 nm

    Science.gov (United States)

    Waritanant, Tanant; Major, Arkady

    2018-02-01

    A passively mode-locked Nd:YVO4 laser operating at 1073 nm and 1085 nm was demonstrated with an intracavity birefringent filter as the wavelength selecting element. The average output powers achieved were 2.17 W and 2.18 W with optical-to-optical efficiency of 19.6% and 19.7%, respectively. The slope efficiencies were more than 31% at both output wavelengths. The pulse durations at the highest average output power were 10.3 ps and 8.4 ps, respectively. We believe that this is the first report of mode locking of a Nd:YVO4 laser operating at 1073 nm or 1085 nm lines.

  4. Harmonic Inverse FEL Interaction at 800nm

    CERN Document Server

    Sears, C M S; Siemann, R; Spencer, J E

    2005-01-01

    The inverse Free Electron Laser (IFEL) interaction has recently been proposed and demonstrated as a premodulator for High Gain Harmonic Generation (HGHG) experiments. These experiments utilized the fundamental of the interaction between the laser field and electron bunch. In the current experiment, we explore the higher order resonances of the IFEL interaction from a 3 period, 1.8 centimeter wavelength undulator with a picosecond, 0.25 mJ/pulse laser at 800nm. The resonances are observed by adjusting the gap of the undulator while keeping the beam energy constant. The harmonic IFEL can add flexibility to HGHG FEL design.

  5. Laser–fibre vibrometry at 1550 nm

    International Nuclear Information System (INIS)

    Waz, A T; Kaczmarek, P R; Abramski, K M

    2009-01-01

    This paper presents new solutions for laser vibrometry, which are based on fibre vibrometry in the third telecommunication window. The scattered laser beam from a vibrating object is guided by a fibre collimator and coherently detected through heterodyning it with an acousto-optical frequency-shifted reference beam. The concept of measuring vibration parameters from many points of the vibrating object has been inspired by wavelength division multiplexing (WDM) in fibre telecommunications. The N-independent WDM separated 15XX nm fibre-coupled laser diodes (used for optical fibre telecommunications) form a system of sources for multipoint vibration measurement according to the rule 'one wavelength–one point'

  6. Structural and Biochemical Characterization of the Oxidoreductase NmDsbA3 from Neisseria meningitidis

    Energy Technology Data Exchange (ETDEWEB)

    Vivian, Julian P.; Scoullar, Jessica; Robertson, Amy L.; Bottomley, Stephen P.; Horne, James; Chin, Yanni; Wielens, Jerome; Thompson, Philip E.; Velkov, Tony; Piek, Susannah; Byres, Emma; Beddoe, Travis; Wilce, Matthew C.J.; Kahler, Charlene M.; Rossjohn, Jamie; Scanlon, Martin J. (UWA); (Monash)

    2009-09-02

    DsbA is an enzyme found in the periplasm of Gram-negative bacteria that catalyzes the formation of disulfide bonds in a diverse array of protein substrates, many of which are involved in bacterial pathogenesis. Although most bacteria possess only a single essential DsbA, Neisseria meningitidis is unusual in that it possesses three DsbAs, although the reason for this additional redundancy is unclear. Two of these N. meningitidis enzymes (NmDsbA1 and NmDsbA2) play an important role in meningococcal attachment to human epithelial cells, whereas NmDsbA3 is considered to have a narrow substrate repertoire. To begin to address the role of DsbAs in the pathogenesis of N. meningitidis, we have determined the structure of NmDsbA3 to 2.3-{angstrom} resolution. Although the sequence identity between NmDsbA3 and other DsbAs is low, the NmDsbA3 structure adopted a DsbA-like fold. Consistent with this finding, we demonstrated that NmDsbA3 acts as a thiol-disulfide oxidoreductase in vitro and is reoxidized by Escherichia coli DsbB (EcDsbB). However, pronounced differences in the structures between DsbA3 and EcDsbA, which are clustered around the active site of the enzyme, suggested a structural basis for the unusual substrate specificity that is observed for NmDsbA3.

  7. High power diode lasers emitting from 639 nm to 690 nm

    Science.gov (United States)

    Bao, L.; Grimshaw, M.; DeVito, M.; Kanskar, M.; Dong, W.; Guan, X.; Zhang, S.; Patterson, J.; Dickerson, P.; Kennedy, K.; Li, S.; Haden, J.; Martinsen, R.

    2014-03-01

    There is increasing market demand for high power reliable red lasers for display and cinema applications. Due to the fundamental material system limit at this wavelength range, red diode lasers have lower efficiency and are more temperature sensitive, compared to 790-980 nm diode lasers. In terms of reliability, red lasers are also more sensitive to catastrophic optical mirror damage (COMD) due to the higher photon energy. Thus developing higher power-reliable red lasers is very challenging. This paper will present nLIGHT's released red products from 639 nm to 690nm, with established high performance and long-term reliability. These single emitter diode lasers can work as stand-alone singleemitter units or efficiently integrate into our compact, passively-cooled Pearl™ fiber-coupled module architectures for higher output power and improved reliability. In order to further improve power and reliability, new chip optimizations have been focused on improving epitaxial design/growth, chip configuration/processing and optical facet passivation. Initial optimization has demonstrated promising results for 639 nm diode lasers to be reliably rated at 1.5 W and 690nm diode lasers to be reliably rated at 4.0 W. Accelerated life-test has started and further design optimization are underway.

  8. Compact corner-pumped Nd:YAG/YAG composite slab 1319 nm/1338 nm laser

    International Nuclear Information System (INIS)

    Liu, H; Gong, M; Wushouer, X; Gao, S

    2010-01-01

    A corner-pumped type is a new pumping type in the diode-pumped solid-state lasers, which has the advantages of high pump efficiency and favorable pump uniformity. A corner-pumped Nd:YAG/YAG composite slab continuous-wave 1319 nm/1338 nm dual-wavelength laser is first demonstrated in this paper. When the cavity length is 25 mm, the maximal output power is up to 7.62 W with a slope efficiency of 16.6% and an optical-to-optical conversion efficiency of 17%. The corresponding spectral line widths of 1319 nm laser and 1338 nm laser are 0.11 and 0.1 nm, respectively. The short-term instability of the output power is better than 1% when the pumping power is 39.5 W. The experimental results show that a corner-pumped type is a kind of feasible schedules in the design of diode-pumped solid-state 1.3 μm lasers with low or medium output powers

  9. Comparison of 193 nm and 308 nm laser liquid printing by shadowgraphy imaging

    Energy Technology Data Exchange (ETDEWEB)

    Palla-Papavlu, A., E-mail: apalla@nipne.ro [National Institute for Lasers, Plasma and Radiation Physics, P.O. Box MG-36, Magurele, RO-077125 Bucharest (Romania); Shaw-Stewart, J. [EMPA, Swiss Federal Laboratories for Materials Testing and Research, Laboratory for Functional Polymers, Überlandstrasse 129, 8600 Dübendorf (Switzerland); Paul Scherrer Institute, General Energy Research Department, 5232 Villigen PSI (Switzerland); Mattle, T. [Paul Scherrer Institute, General Energy Research Department, 5232 Villigen PSI (Switzerland); Dinca, V. [National Institute for Lasers, Plasma and Radiation Physics, P.O. Box MG-36, Magurele, RO-077125 Bucharest (Romania); Lippert, T.; Wokaun, A. [Paul Scherrer Institute, General Energy Research Department, 5232 Villigen PSI (Switzerland); Dinescu, M. [National Institute for Lasers, Plasma and Radiation Physics, P.O. Box MG-36, Magurele, RO-077125 Bucharest (Romania)

    2013-08-01

    Over the last years laser-induced forward transfer has emerged as a versatile and powerful tool for engineering surfaces with active compounds. Soft, easily damageable materials can be transferred using a triazene polymer as a sacrificial layer which acts as a pressure generator and at the same time protects the material from direct laser irradiation. To understand and optimize the transfer process of biomolecules in liquid solution by using an intermediate triazene polymer photosensitive layer, shadowgraphy imaging is carried out. Two laser systems i.e. an ArF laser operating at 193 nm and a XeCl laser operating at 308 nm are applied for the transfer. Solutions with 50% v/v glycerol concentration are prepared and the influence of the triazene polymer sacrificial layer thickness (60 nm) on the deposits is studied. The shadowgraphy images reveal a pronounced difference between laser-induced forward transfer using 193 nm or 308 nm, i.e. very different shapes of the ejected liquid.

  10. Read-through transcript from NM23-H1 into the neighboring NM23-H2 gene encodes a novel protein, NM23-LV

    NARCIS (Netherlands)

    Valentijn, Linda J.; Koster, Jan; Versteeg, Rogier

    2006-01-01

    NM23-H1 and NM23-H2 are neighboring genes on chromosome 17q. They encode nucleoside diphosphate kinases that have additional roles in signal transduction, transcription, and apoptosis. NM23-H1 expression is a strong marker for prognosis and metastatic behavior in many tumor types. A new

  11. 308-nm excimer laser in endodontics

    Science.gov (United States)

    Liesenhoff, Tim

    1992-06-01

    Root canal preparation was performed on 20 extracted human teeth. After opening the coronal pulp, the root canals were prepared by 308 nm excimer laser only. All root canals were investigated under SEM after separation in the axial direction. By sagittal separation of the mandibles of freshly slaughtered cows, it was possible to get access to the tissues and irradiate under optical control. Under irradiation of excimer laser light, tissue starts to fluoresce. It was possible to demonstrate that each tissue (dentin, enamel, bone, pulpal, and connective tissue) has a characteristic spectral pattern. The SEM analyses showed that it is well possible to prepare root canals safely. All organic soft tissue has been removed by excimer laser irradiation. There was no case of via falsa. The simultaneous spectroscopic identification of the irradiated tissue provides a safe protection from overinstrumentation. First clinical trials on 20 patients suffering of chronical apical parodontitis have been carried out successfully.

  12. Ocular effects of ultraviolet radiation from 295 to 365 nm

    International Nuclear Information System (INIS)

    Pitts, D.G.; Cullen, A.P.; Hacker, P.D.

    1977-01-01

    A 5,000 watt Xe--Hg source and a double monochromator were used to produce 6.6 nm full band-pass ultraviolet (UV) radiation. Pigmented rabbit eyes were exposed to the 6.6 nm band-pass UV radiant energy in 5 nm steps from 295 to 320 nm and at random intervals above 320 nm. Corneal and lenticular damage was assessed and classified with a biomicroscope. Corneal threshold radiant exposure (Hc) rose very rapidly from 0.022 Jcm -2 at 300 nm to 10.99 Jcm -2 at 335 nm. Radiant exposures exceeding 2 x Hc resulted in irreversible corneal damage. Lenticular damage was limited to wavebands above 295 nm. The action spectrum for the lens began at 295 nm and extended to about 315 nm. Permanent lenticular damage occurred at radiant exposure levels approximately twice the threshold for lenticular radiant exposure. The importance in establishing both corneal and lenticular damage criteria is emphasized

  13. Absolute frequency atlas from 915 nm to 985 nm based on laser absorption spectroscopy of iodine

    Science.gov (United States)

    Nölleke, Christian; Raab, Christoph; Neuhaus, Rudolf; Falke, Stephan

    2018-04-01

    This article reports on laser absorption spectroscopy of iodine gas between 915 nm and 985 nm. This wavelength range is scanned utilizing a narrow linewidth and mode-hop-free tunable diode-laser whose frequency is actively controlled using a calibrated wavelength meter. This allows us to provide an iodine atlas that contains almost 10,000 experimentally observed reference lines with an uncertainty of 50 MHz. For common lines, good agreement is found with a publication by Gerstenkorn and Luc (1978). The new rich dataset allows existing models of the iodine molecule to be refined and can serve as a reference for laser frequency calibration and stabilization.

  14. Laser Shock Processing of 6061-T6 Al alloy with 1064 nm and 532 nm wavelengths

    International Nuclear Information System (INIS)

    Gomez-Rosas, G.; Rubio-Gonzalez, C.; Ocana, J.L.; Molpeceres, C.; Porro, J.A.; Morales, M.; Casillas, F.J.

    2010-01-01

    Laser Shock Processing (LSP) has been proposed as a competitive alternative technology to classical treatments for improving fatigue and wear resistance of metals. We present a configuration and results in the LSP concept for metal surface treatments in underwater laser irradiation at 532 nm and 1064 nm. The purpose of the work is to compare the effect of both wavelengths on the same material. A convergent lens is used to deliver 1.2 J/pulse (1064 nm) and 0.9 J/pulse (532 nm) in a 8 ns laser FWHM pulse produced by 10 Hz Q-switched Nd:YAG laser with spots of a 1.5 mm in diameter moving forward along the work piece. A LSP configuration with experimental results using a pulse density of 2500 pulses/cm 2 and 5000 pulses/cm 2 in 6061-T6 aluminum samples are presented. High level compressive residual stresses are produced using both wavelengths. It has been shown that surface residual stress level is comparable to that achieved by conventional shot peening, but with greater depths. This method can be applied to surface treatment of final metal products.

  15. Characterization of LANDSAT Panels Using the NIST BRDF Scale from 1100 nm to 2500 nm

    Science.gov (United States)

    Markham, Brian; Tsai, Benjamin K.; Allen, David W.; Cooksey, Catherine; Yoon, Howard; Hanssen, Leonard; Zeng, Jinan; Fulton, Linda; Biggar, Stuart; Markham, Brian

    2010-01-01

    Many earth observing sensors depend on white diffuse reflectance standards to derive scales of radiance traceable to the St Despite the large number of Earth observing sensors that operate in the reflective solar region of the spectrum, there has been no direct method to provide NIST traceable BRDF measurements out to 2500 rim. Recent developments in detector technology have allowed the NIST reflectance measurement facility to expand the operating range to cover the 250 nm to 2500 nm range. The facility has been modified with and additional detector using a cooled extended range indium gallium arsenide (Extended InGaAs) detector. Measurements were made for two PTFE white diffuse reflectance standards over the 1100 nm to 2500 nm region at a 0' incident and 45' observation angle. These two panels will be used to support the OLI calibration activities. An independent means of verification was established using a NIST radiance transfer facility based on spectral irradiance, radiance standards and a diffuse reflectance plaque. An analysis on the results and associated uncertainties will be discussed.

  16. Combination of 595-nm pulsed dye laser, long-pulsed 755-nm alexandrite laser, and microdermabrasion treatment for keratosis pilaris: retrospective analysis of 26 Korean patients.

    Science.gov (United States)

    Lee, Sang Ju; Choi, Min Ju; Zheng, Zhenlong; Chung, Won Soon; Kim, Young Koo; Cho, Sung Bin

    2013-06-01

    Keratosis pilaris (KP) has beenpresented as small keratotic follicular papules with or without surrounding erythema. Various treatments with laser or light therapy have been used for the management of KP with various clinical outcomes. In the present study, we investigated the efficacy and safety of a combination therapy for KP. A total of 29 anatomical sites with KP in 26 patients were treated using a 595-nm pulsed dye laser (PDL) with nonpurpuragenic fluences, a long-pulsed 755-nm alexandrite laser, and microdermabrasion. Clinical improvement was assessed by comparing preand posttreatment clinical photographs and patient satisfaction rates. Evaluation of the clinical results three months after the treatments showed that 12 of the 29 anatomical sites (41.4%) demonstrated Grade 3 clinical improvement, ten (34.5%) had Grade 2 clinical improvement, four (13.8%) showed Grade 1 improvement, and three (10.3%) showed Grade 4 improvement. We observed that KP lesions improved not only in erythema and skin texture, but also in brownish dyschromias. Potential adverse events were not observed, except prolonged posttherapy scaling. Our observations demonstrate that combination therapy using a 595-nm PDL, a long-pulsed 755-nm alexandrite laser, and microdermabrasion can have a positive therapeutic effect on KP.

  17. PILOT STUDY: Report on the CCPR Pilot Comparison: Spectral Responsivity 10 nm to 20 nm

    Science.gov (United States)

    Scholze, Frank; Vest, Robert; Saito, Terubumi

    2010-01-01

    The CCPR Pilot Comparison on spectral responsivity in the 10 nm to 20 nm spectral range was carried out within the framework of the CIPM Mutual Recognition Arrangement by three laboratories: PTB (Germany), NIST (USA), and NMIJ/AIST (Japan) with PTB acting as the central and reporting laboratory. All participating laboratories used monochromatized synchrotron radiation. PTB and NIST used a cryogenic radiometer as the primary standard detector and NMIJ, an ionization chamber with extrapolation by a wavelength-independent detector. The aim of the pilot comparison was to check the accuracy of the radiometric scale of spectral responsivity in the short wavelength EUV spectral range which has recently gained in technological importance. The wavelengths of measurement were from 11.5 nm to 20 nm in 0.5 nm steps and additionally 12.2 nm. The comparison was carried out through the calibration of a group of transfer standard detectors. Two sets of three diodes of types AXUV and SXUV from International Radiation Detectors, Inc. were used for the comparison. The comparison had the form of a star comparison: Pilot-lab A-pilot-lab B-pilot, PTB acting as the pilot laboratory. All results were communicated directly to the pilot laboratory. The report describes in detail the measurements made at PTB and summarizes the reports submitted by the participants. Measurements carried out by the pilot laboratory before and after the circulation of the detectors proved that the stability of the detectors was sufficient for the comparison. For the type AXUV detectors, however, changes in their responsivity contributed to the uncertainty of the comparison. Measurement results from participants and their associated uncertainties were analyzed in this report according to the Guidelines for CCPR Comparison Report Preparation. The uncertainty contributions were separated, as to whether they are wavelength dependent or not. All bilateral DoE are well within the respective k = 2 expanded uncertainty

  18. Magnetic Susceptibility of liquid Gd-NM (NM = Cu, Ga, Ge alloys

    Directory of Open Access Journals (Sweden)

    Shimakura Hironori

    2017-01-01

    Full Text Available For rare earth alloys, the indirect interaction of RKKY is at work between rare-earth atoms. Therefore, the magnetism of them depends on the number of conduction electrons and the distance between rare-earth metals. In this work, to reveal the relationship between the number of conduction electrons and magnetic property of rare earth metal alloys, magnetic susceptibility measurements for liquid Gd-NM (NM = Cu, Ga, Ge was performed by Faraday method. As the results, it was observed that the sign of paramagnetic Curie temperature of Cu-Gd alloys are positive at all composition, while Ga-Gd and Ge-Gd alloys show negative paramagnetic Curie temperature at certain composition. Moreover, it was indicated when the alloy at certain composition shows highest melting temperature, it has the lowest paramagnetic Curie temperature.

  19. TUNABLE DIODE LASER MEASUREMENTS OF NO2 NEAR 670 NM AND 395 NM. (R823933)

    Science.gov (United States)

    Two single-mode diode lasers were used to record high-resolution absorption spectra of NO2 (dilute in Ar) near 670.2 and 394.5 nm over a range of temperatures (296 to 774 K) and total pressures (2.4 x 10(-2) to 1 atm). A commercial InGaAsP laser was tuned 1.3 cm(-1) at a repetiti...

  20. Monolithic PM Raman fiber laser at 1679 nm for Raman amplification at 1810 nm

    DEFF Research Database (Denmark)

    Svane, Ask Sebastian; Rottwitt, Karsten

    2013-01-01

    Stimulated Raman scattering (SRS) has been subject to much attention within the field of fiber lasers and amplifiers as it provides an extended wavelength coverage in comparison to rare-earth based devices. Motivated by the projected capacity crunch [1], different approaches are being explored...... demonstrate a monolithic RM Raman fiber laser (RFL), which acts as a pump for a Raman amplifier (RA) at 1810 nm. The lasing wavelength of a RFL, thus also for a RA, can in principle be designed arbitrarily within the entire wavelength range from the Erbium band up to the Thulium/Holmium band...... of OFS PM Raman fiber, with an estimated propagation loss of 0.42/0.46/1.3 dB/km at 1564/1679/1810 nm. The Raman gain coefficient was measured to be gR=2.66/2.35 W-1km-1 at 1679/1810 nm. The laser curve of the RFL is depicted in Fig. 1b, with a slope efficiency of 67 %. The high slope efficiency...

  1. Stimulation of DNA synthesis by 340nm/ 351nm UV laser irradiation

    International Nuclear Information System (INIS)

    Meldrum, R.A.; Wharton, C.W.

    1991-01-01

    During preliminary experiments designed to test the feasibility of using a 'caged' DNA break trapping agent, the authors observed a stimulation of incorporation of 3 H-thymidine into DNA when cells were irradiated with low doses (100-1000J/m 2 ) of 351nm UV laser irradiation. This wavelength is used to photolyse 'caged' dideoxynucleotides in our fast time course measurements of DNA repair in mammalian cells. The dose at which this stimulation was observed is well below that at which measurable damage is detected. (author)

  2. Picosecond laser damage of fused silica at 355 nm

    International Nuclear Information System (INIS)

    Meng Xiangjie; Liu Hongjie; Wang Fang; Zhang Zhen; An Xinyou; Huang Jin; Jiang Xiaodong; Wu Weidong; Ren Weiyi

    2013-01-01

    This paper studies the initiated damage threshold, the damage morphology and the subsequent damage growth on fused silica's input-surface and exit-surface under picosecond laser irradiation at 355 nm. Defects induced fluorescence on surface of the optical component is observed. The results demonstrate a significant dependence of the initiated damage on pulse duration and surface defects, and that of the damage growth on self-focusing, sub-surface defects. The damage-threshold is 3.98 J/cm 2 of input surface and 2.91 J/cm 2 of exit surface. The damage morphologies are quite different between input surface and exit surface. Slow growth behavior appears for the diameter of exit-surface and linear growth one for the depth of exit-surface in the lateral side of damage site with the increase of shot number. Defects have changed obviously compared with nanosecond laser damage in the damage area. Several main reasons such as electric intensification and self-focusing for the observed initiated damage and damage growth behavior are discussed. (authors)

  3. Investigating Degradation Mechanisms in 130 nm and 90 nm Commercial CMOS Technologies Under Extreme Radiation Conditions

    Science.gov (United States)

    Ratti, Lodovico; Gaioni, Luigi; Manghisoni, Massimo; Traversi, Gianluca; Pantano, Devis

    2008-08-01

    The purpose of this paper is to study the mechanisms underlying performance degradation in 130 nm and 90 nm commercial CMOS technologies exposed to high doses of ionizing radiation. The investigation has been mainly focused on their noise properties in view of applications to the design of low-noise, low-power analog circuits to be operated in harsh environment. Experimental data support the hypothesis that charge trapping in shallow trench isolation (STI), besides degrading the static characteristics of interdigitated NMOS transistors, also affects their noise performances in a substantial fashion. The model discussed in this paper, presented in a previous work focused on CMOS devices irradiated with a 10 Mrad(SiO2) gamma -ray dose, has been applied here also to transistors exposed to much higher (up to 100 Mrad(SiO2 )) doses of X-rays. Such a model is able to account for the extent of the observed noise degradation as a function of the device polarity, dimensions and operating point.

  4. Original papers A study on efficacy of 308 nm excimer light therapy in alopecia areata

    Directory of Open Access Journals (Sweden)

    Zo Nun Sanga

    2015-06-01

    Full Text Available Introduction. Alopecia areata (AA is an autoimmune condition characterized by T-cell-mediated attack on hair follicles. Objective. Evaluation of efficacy of 308 nm excimer light in the treatment of alopecia areata. Material and methods. Patches of AA were treated twice weekly, but not on 2 consecutive days, with UVB excimer 308 nm light. In all patients, half of the AA patch was irradiated and the other half was spared, covered with a black rubber shield and taken as a control. Therapy was started with an initial dose of 300 mJ/cm 2 , with an incremental dose of 100 mJ/cm 2 at every sitting until fine erythema appeared. Results. At the end of the treatment, one patient (3.33% at the test site showed > 50% hair regrowth vs. none at the control site. After a 2-month post-treatment period, successful hair regrowth (grades 3 and 4 was seen in 12 patients at test sites and in 2 patients at control sites. The differences were statistically significant (p < 0.05. After 4 months successful hair regrowth (grades 3 and 4 was seen in 16 patients at test sites and in 5 patients at control sites. The differences were statistically significant (p 0.05. Conclusions. Excimer light has the potential to stimulate hair regrowth in patches of alopecia areata.

  5. First principles study on the interfacial properties of NM/graphdiyne (NM = Pd, Pt, Rh and Ir): The implications for NM growing

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Zhansheng; Li, Shuo; Lv, Peng [College of Physics and Electronic Engineering, Henan Normal University, Xinxiang 453007 (China); He, Chaozheng, E-mail: hecz2013@nynu.edu.cn [College of Physics and Electronic Engineering, Nanyang Normal University, Nanyang 473061 (China); Ma, Dongwei [School of Physics, Anyang Normal University, Anyang 455000 (China); Yang, Zongxian, E-mail: yzx@henannu.edu.cn [College of Physics and Electronic Engineering, Henan Normal University, Xinxiang 453007 (China); Collaborative Innovation Center of Nano Functional Materials and Applications, Kaifeng (China)

    2016-01-01

    Graphical abstract: - Highlights: • The NM adatoms belong to embedded adsorption in 18C-hexagon of GDY. • The Rh and Ir/GDY can be applied to single metal catalysts or sensors. • A simple linear relationship between E{sub e-ads} and E{sub b} is presented. • The linear relationship can be used in the noble metal modified GDY. - Abstract: Based on the dispersion-corrected density functional calculations (DFT-D), we systematically studied the adsorption of noble metals (NM), Pd, Pt, Rh and Ir, on graphdiyne (GDY). We present a systematic study on the geometry, embedded adsorption energy and electronic structure of four different adatoms adsorbed on the GDY. The strong interaction between the NM adatoms and the GDY substrate is found with the NM embedded in the 18C-hexagon of the GDY. We investigated the mobility of the NM adatoms on the GDY, and found that the mobility barrier energy increases along with the increasing of the embedded adsorption energy. We present the NM adatoms growth of high concentrations on the GDY. Upon the analysis of the electronic structure and the frontier molecular orbitals, Rh and Ir adatoms of low concentrations (about 1.37 at%) on the GDY have the potential to be applied as single metal catalysts or gas molecule sensors.

  6. Growth of Laser Initiated Damage in Fused Silica at 527 nm

    International Nuclear Information System (INIS)

    Norton, M A; Donohue, E E; Hollingsworth, W G; McElroy, J N; Hackel, R P

    2003-01-01

    The effective lifetime of optics is limited by both laser-induced damage and the subsequent growth of laser initiated damage sites. We have measured the growth rate of laser-induced damage in fused silica in both air and vacuum at 527 nm. For damage on the exit surface, the data shows exponential growth in the lateral size of the damage site with shot number. The exponential growth coefficient depends linearly on the laser fluence. The behavior at the fluence threshold for growth is contrasted to that observed at 351 nm. The growth rate was not significantly affected by either the wavelength of the initiating fluence or the presence of 10 torr of air as compared to vacuum. When the damage is located on the input surface, it has both a higher threshold for growth and does not grow exponentially

  7. Induction of DNA-protein cross-linking in Chinese hamster cells by monochromatic 365 and 405 NM ultraviolet light

    International Nuclear Information System (INIS)

    Han, A.; Peak, M.J.; Peak, J.G.

    1984-01-01

    The survival, the induction of DNA-protein cross-linking, and the number of T4-endonuclease sensitive sites were measured in Chinese hamster cells that had been irradiated with 365 and 405 nm monochromatic light. The survival measurements show that cells are somewhat less sensitive to 405 nm light than to 365 nm light. The difference is expressed predominantly in the shoulder widths of the survival curves, whereas the slopes of the two curves are about the same. Induction of pyrimidine dimers, as indicated by the number of endonuclease-sensitive sites, after exposures that produce about 10% survival is very low at 365 nm (approx. 4 endonuclease sites per 2 x 10 8 daltons), while no dimers are detected at 405 nm. In contrast, DNA-protein cross-links are induced rather effectively at either wavelength even after exposures that result in a relatively high survival (60-20%). These measurements support the conclusion that lethality in mammalian cells after irradiations with 365 or 405 nm light is caused by a nondimer damage, possibly DNA-protein cross-links. (author)

  8. Laser-Induced Damage Growth on Larger-Aperture Fused Silica Optical Components at 351 nm

    International Nuclear Information System (INIS)

    Wan-Qing, Huang; Wei, Han; Fang, Wang; Yong, Xiang; Fu-Quan, Li; Bin, Feng; Feng, Jing; Xiao-Feng, Wei; Wan-Guo, Zheng; Xiao-Min, Zhang

    2009-01-01

    Laser-induced damage is a key lifetime limiter for optics in high-power laser facility. Damage initiation and growth under 351 nm high-fluence laser irradiation are observed on larger-aperture fused silica optics. The input surface of one fused silica component is damaged most severely and an explanation is presented. Obscurations and the area of a scratch on it are found to grow exponentially with the shot number. The area of damage site grows linearly. Micrographs of damage sites support the micro-explosion damage model which could be used to qualitatively explain the phenomena

  9. Humboldt Open Ocean Disposal Site (HOODS) Survey Work 2014

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Humboldt Open Ocean Disposal Site (HOODS) is a dredged material disposal site located 3 nautical miles (nm) offshore of Humboldt Bay in Northern California....

  10. High-efficency stable 213-nm generation for LASIK application

    Science.gov (United States)

    Wang, Zhenglin; Alameh, Kamal; Zheng, Rong

    2005-01-01

    213nm Solid-state laser technology provides an alternative method to replace toxic excimer laser in LASIK system. In this paper, we report a compact fifth harmonic generation system to generate high pulse energy 213nm laser from Q-switched Nd:YAG laser for LASIK application based on three stages harmonic generation procedures. A novel crystal housing was specifically designed to hold the three crystals with each crystal has independent, precise angular adjustment structure and automatic tuning control. The crystal temperature is well maintained at ~130°C to improve harmonic generation stability and crystal operation lifetime. An output pulse energy 35mJ is obtained at 213nm, corresponding to total conversion efficiency ~10% from 1064nm pump laser. In system verification tests, the 213nm output power drops less than 5% after 5 millions pulse shots and no significant damage appears in the crystals.

  11. Thin film and multilayer optics for XUV spectral domain (1 nm to 60 nm)

    International Nuclear Information System (INIS)

    Delmotte, Franck

    2010-02-01

    The XUV spectral domain (1-60 nm wavelength range) has experienced rapid growth in recent years. On one side, the sources (synchrotron radiation, harmonic generation, x-ray laser, free-electron laser...) require ever more efficient optics, on the other hand, applications (diagnostics of hot plasma, solar physics, x-ray microscopy, EUV lithography, x-ray analysis...) provide new constraints on the design of multilayer stacks. The multilayer mirrors are the only way to achieve efficient optics operating at non-grazing incidence angles in this spectral range. Our work within the team XUV Optics at Laboratoire Charles Fabry de l'Institut d'Optique focuses on the study of materials in thin layers correlated to the study of optical properties of multilayers. The objective is to achieve new multilayer components previously unavailable in the XUV domain, through a better understanding of physical phenomena in these nano-layer stacks. We show through several examples of how we have managed both to improve the performance of multilayer mirrors in a broad spectral range, and secondly, to develop new optical functions: beam splitters, broadband mirrors, dual-band mirrors or phase compensation mirrors. (author)

  12. Picosecond laser texturization of mc-silicon for photovoltaics: A comparison between 1064 nm, 532 nm and 355 nm radiation wavelengths

    Energy Technology Data Exchange (ETDEWEB)

    Binetti, Simona [Department of Materials Science and Milano-Bicocca Solar Energy Research Center (MIB-SOLAR), University of Milano-Bicocca, Via Cozzi 55, 20125 Milano (Italy); Le Donne, Alessia, E-mail: alessia.ledonne@mater.unimib.it [Department of Materials Science and Milano-Bicocca Solar Energy Research Center (MIB-SOLAR), University of Milano-Bicocca, Via Cozzi 55, 20125 Milano (Italy); Rolfi, Andrea [Department of Materials Science and Milano-Bicocca Solar Energy Research Center (MIB-SOLAR), University of Milano-Bicocca, Via Cozzi 55, 20125 Milano (Italy); Jäggi, Beat; Neuenschwander, Beat [Bern University of Applied Sciences, Engineering and Information Technology, Institute for Applied Laser, Photonics and Surface Technologies ALPS, Pestalozzistrasse 20, CH-3400 Burgdorf (Switzerland); Busto, Chiara [ENI Spa, Via Giacomo Fauser, 4, 28100 Novara (Italy); Frigeri, Cesare [CNR-IMEM Institute, Parco Area Delle Scienze 37/A, Fontanini, 43010 Parma (Italy); Scorticati, Davide; Longoni, Luca; Pellegrino, Sergio [Laserpoint Srl, Via Della Burrona 51, 20090 Vimodrone, Milano (Italy)

    2016-05-15

    Highlights: • Self-organized surface structures were produced by picosecond laser pulses on mc-Si. • Three laser wavelengths were used which effectively reduce Si reflectivity up to 8%. • The subsurface damage induced by the three lasers was studied in detail. • μ-Raman, PL and TEM proved that UV laser provides the lowest subsurface damage. • UV laser induced damage is located above the depletion region of the p–n junction. - Abstract: Self-organized surface structures were produced by picosecond laser pulses on multi-crystalline silicon for photovoltaic applications. Three different laser wavelengths were employed (i.e. 1064 nm, 532 nm and 355 nm) and the resulting morphologies were observed to effectively reduce the reflectivity of the samples after laser irradiation. Besides, a comparative study of the laser induced subsurface damage generated by the three different wavelengths was performed by confocal micro-Raman, photoluminescence and transmission electron microscopy. The results of both the structural and optical characterization showed that the mc-Si texturing performed with the laser at 355 nm provides surface reflectivity between 11% and 8% over the spectral range from 400 nm to 1 μm, while inducing the lowest subsurface damage, located above the depletion region of the p–n junction.

  13. Site Features

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset consists of various site features from multiple Superfund sites in U.S. EPA Region 8. These data were acquired from multiple sources at different times...

  14. Development of 2-channel (532 nm and 355 nm) mobile LIDAR for mapping particulate matter in the atmosphere

    CSIR Research Space (South Africa)

    Sivakumar, V

    2010-09-01

    Full Text Available In this paper, the authors describe the developmentof 2-Channel (532 nm and 355 nm) mobile LIDAR system for studying atmospheric particulate matter. The system is currently tested in house at the Council for Scientific and Industrial Research...

  15. Wavelength dependence on the forensic analysis of glass by nanosecond 266 nm and 1064 nm laser induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Cahoon, Erica M.; Almirall, Jose R.

    2010-05-01

    Laser induced breakdown spectroscopy can be used for the chemical characterization of glass to provide evidence of an association between a fragment found at a crime scene to a source of glass of known origin. Two different laser irradiances, 266 nm and 1064 nm, were used to conduct qualitative and quantitative analysis of glass standards. Single-pulse and double-pulse configurations and lens-to-sample-distance settings were optimized to yield the best laser-glass coupling. Laser energy and acquisition timing delays were also optimized to result in the highest signal-to-noise ratio corresponding to the highest precision and accuracy. The crater morphology was examined and the mass removed was calculated for both the 266 nm and 1064 nm irradiations. The analytical figures of merit suggest that the 266 nm and 1064 nm wavelengths are capable of good performance for the forensic chemical characterization of glass. The results presented here suggest that the 266 nm laser produces a better laser-glass matrix coupling, resulting in a better stoichiometric representation of the glass sample. The 266 nm irradiance is therefore recommended for the forensic analysis and comparison of glass samples.

  16. Wavelength dependence on the forensic analysis of glass by nanosecond 266 nm and 1064 nm laser induced breakdown spectroscopy

    International Nuclear Information System (INIS)

    Cahoon, Erica M.; Almirall, Jose R.

    2010-01-01

    Laser induced breakdown spectroscopy can be used for the chemical characterization of glass to provide evidence of an association between a fragment found at a crime scene to a source of glass of known origin. Two different laser irradiances, 266 nm and 1064 nm, were used to conduct qualitative and quantitative analysis of glass standards. Single-pulse and double-pulse configurations and lens-to-sample-distance settings were optimized to yield the best laser-glass coupling. Laser energy and acquisition timing delays were also optimized to result in the highest signal-to-noise ratio corresponding to the highest precision and accuracy. The crater morphology was examined and the mass removed was calculated for both the 266 nm and 1064 nm irradiations. The analytical figures of merit suggest that the 266 nm and 1064 nm wavelengths are capable of good performance for the forensic chemical characterization of glass. The results presented here suggest that the 266 nm laser produces a better laser-glass matrix coupling, resulting in a better stoichiometric representation of the glass sample. The 266 nm irradiance is therefore recommended for the forensic analysis and comparison of glass samples.

  17. Histologic evaluation of laser lipolysis: pulsed 1064-nm Nd:YAG laser versus cw 980-nm diode laser.

    Science.gov (United States)

    Mordon, Serge; Eymard-Maurin, Anne Françoise; Wassmer, Benjamin; Ringot, Jean

    2007-01-01

    The use of the laser as an auxiliary tool has refined the traditional technique for lipoplasty. During laser lipolysis, the interaction between the laser and the fat produced direct cellular destruction before the suction, reduced bleeding, and promoted skin tightening. This study sought to perform a comparative histologic evaluation of laser lipolysis with the pulsed 1064-nm Nd:YAG laser versus a continuous 980-nm diode laser. A pulsed 1064-nm Nd:YAG (Smart-Lipo; Deka, Italy) and a CW 980-nm diode laser (Pharaon, Osyris, France) were evaluated at different energy settings for lipolysis on the thighs of a fresh cadaver. The lasers were coupled to a 600-microm optical fiber inserted in a 1-mm diameter cannula. Biopsy specimens were taken on irradiated and non-irradiated areas. Hematoxylin-erythrosin-safran staining and immunostaining (anti-PS100 polyclonal antibody) were performed to identify fat tissue damage. In the absence of laser exposures (control specimens), cavities created by cannulation were seen; adipocytes were round in appearance and not deflated. At low energy settings, tumescent adipocytes were observed. At higher energy settings, cytoplasmic retraction, disruption of membranes, and heat-coagulated collagen fibers were noted; coagulated blood cells were also present. For the highest energy settings, carbonization of fat tissue involving fibers and membranes was clearly seen. For equivalent energy settings, 1064-nm and 980-nm wavelengths gave similar histologic results. Laser lipolysis is a relatively new technique that is still under development. Our histologic findings suggest several positive benefits of the laser, including skin retraction and a reduction in intraoperative bleeding. The interaction of the laser with the tissue is similar at 980 nm and 1064 nm with the same energy settings. Because higher volumes of fat are removed with higher total energy, a high-power 980-nm diode laser could offer an interesting alternative to the 1064-nm Nd

  18. Tapered diode laser pumped 946 nm Nd:YAG laser

    DEFF Research Database (Denmark)

    Cheng, Haynes Pak Hay; Jensen, Ole Bjarlin; Petersen, Paul Michael

    2009-01-01

    We successfully implemented a 946 nm Nd:YAG laser based on a 808 nm tapered diode pump laser. The tapered diode is developed at the Ferdinand-Braun-Institute fur Hochstfrequenztechnik in Germany. Figure 2 shows the experimental setup and results of each pump source coupled into a 1.5 mm crystal...... laser, we show that tapered diode laser pumping potentially increase the power of 946 nm lasers by a factor of two and reduce the threshold by a factor of three....

  19. Site decontamination

    International Nuclear Information System (INIS)

    Bicker, A.E.

    1981-01-01

    Among the several DOE sites that have been radiologically decontaminated under the auspices of the Nevada Operations Office are three whose physical characteristics are unique. These are the Tatum Dome Test Site (TDTS) near Hattiesburg, Mississippi; a location of mountainous terrain (Pahute Mesa) on the Nevada Test Site; and the GNOME site near Carlsbad, New Mexico. In each case the contamination, the terrain, and the climate conditions were different. This presentation includes a brief description of each site, the methods used to perform radiological surveys, the logistics required to support the decontamination (including health physics and sample analysis), and the specific techniques used to reduce or remove the contamination

  20. Site organization and site arrangement

    International Nuclear Information System (INIS)

    Boissonnet, B.; Macqueron, J.F.

    1976-01-01

    The present paper deals with criteria for the choice of a production unit or power plant site, the organization and development of a site in terms of its particular characteristics and takes into account personnel considerations in site organizations as well as the problem of integrating the architecture into the environment. (RW) [de

  1. CORRECTION OF THE TEMPERATURE EFFECT IN 1020 NM BAND OF SUN-SKY RADIOMETER

    Directory of Open Access Journals (Sweden)

    K. Li

    2018-04-01

    Full Text Available Aerosol is an important part of the earth-atmosphere system. It can directly and indirectly influence solar radiation and then affect the energy balance of earth-atmosphere system. AERONET, as the largest ground-based observation network, provides multi-parameters of aerosol from more than 600 hundred sites using sun-sky radiometer, which contains 9 channels from 340 nm to 1640 nm. Among which, 1020 nm channel is greatly influenced by the temperature. In this paper, a new correction method of 1020 nm band is introduced. The new method transfers the temperature correction coefficient of the master radiometer to the comparative one. The filed calibration experiment shown that the temperature correction coefficient obtained by this method is close to the result from the temperature controlled chamber, and the difference is about 2.1 %. This new method is easy-to-use, and its accuracy is comparable to the standard one. It is more applicable for large-scale instrument calibration. In principle, this method is applicable to all bands of the sun-sky radiometer.

  2. Correction of the Temperature Effect in 1020 NM Band of Sun-Sky Radiometer

    Science.gov (United States)

    Li, K.; Li, Z.; Li, D.; Xie, Y.; Xu, H.

    2018-04-01

    Aerosol is an important part of the earth-atmosphere system. It can directly and indirectly influence solar radiation and then affect the energy balance of earth-atmosphere system. AERONET, as the largest ground-based observation network, provides multi-parameters of aerosol from more than 600 hundred sites using sun-sky radiometer, which contains 9 channels from 340 nm to 1640 nm. Among which, 1020 nm channel is greatly influenced by the temperature. In this paper, a new correction method of 1020 nm band is introduced. The new method transfers the temperature correction coefficient of the master radiometer to the comparative one. The filed calibration experiment shown that the temperature correction coefficient obtained by this method is close to the result from the temperature controlled chamber, and the difference is about 2.1 %. This new method is easy-to-use, and its accuracy is comparable to the standard one. It is more applicable for large-scale instrument calibration. In principle, this method is applicable to all bands of the sun-sky radiometer.

  3. Northern Edge Navajo Casino, Fruitland, NM: NN0030343

    Science.gov (United States)

    NPDES Permit and Fact Sheet explaining EPA's action under the Clean Water Act to issue NPDES Permit No. NN0030343) to the Navajo Tribal Utility Authority Northern Edge Navajo Casino Wastewater Treatment Facility, 2752 Indian Service Road 36, Fruitland, NM.

  4. Compact 2050 nm Semiconductor Diode Laser Master Oscillator, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase I effort seeks to develop DFB laser master oscillators at the novel wavelength of 12050 nm. Two prototypes will be built, tested, and delivered ....

  5. Transcanalicular laser dacryocystorhinostomy using low energy 810 nm diode laser

    Directory of Open Access Journals (Sweden)

    Sanjiv K Gupta

    2012-01-01

    Conclusions: Transcanalicular Laser DCR can be safely performed using a low power 810 nm diode laser. The surgery is elegant, minimally invasive, allows fast rehabilitation, and has an excellent success rate.

  6. Photorefractive effect at 775 nm in doped lithium niobate crystals

    Energy Technology Data Exchange (ETDEWEB)

    Nava, G.; Minzioni, P.; Cristiani, I.; Degiorgio, V. [Department of Electrical, Computer, and Biomedical Engineering, and CNISM, University of Pavia, 27100 Pavia (Italy); Argiolas, N.; Bazzan, M.; Ciampolillo, M. V.; Pozza, G.; Sada, C. [Physics and Astronomy Departement, University of Padova, 35131 Padova (Italy)

    2013-07-15

    The photorefractive effect induced by 775-nm laser light on doped lithium niobate crystals is investigated by the direct observation in the far field of the transmitted-beam distortion as a function of time. Measurements performed at various Zr-doping concentrations and different light intensities show that the 775-nm light beam induces a steady-state photorefractive effect comparable to that of 532-nm light, but the observed build-up time of the photovoltaic field is longer by three-orders of magnitude. The 775-nm photorefractivity of lithium niobate crystals doped with 3 mol. % ZrO{sub 2} or with 5.5 mol. % MgO is found to be negligible.

  7. Removing foxing stains from old paper at 157 nm

    International Nuclear Information System (INIS)

    Sarantopoulou, E.; Samardzija, Z.; Kobe, S.; Kollia, Z.; Cefalas, A.C.

    2003-01-01

    Using a molecular fluorine laser at 157 nm foxing stains were removed successfully from a 16th century old paper. Laser cleaning of stains and foxing from old paper manuscripts is far more effective at 157 nm in comparison to different wavelengths without leaving any yellowish after-effect on the paper. This is because at 157 nm illumination of old paper, complete bond breaking of all the organic molecules of the paper is taking place. Mass spectroscopy at 157 nm and for moderate laser intensities up to 1 mJ/cm 2 of old paper suffering from foxing indicate organic matter disintegration to small photofragments atomic, diatomic or triatomic, which are flying apart with supersonic speed. In addition high spatial resolution energy dispersive X-ray system (EDXS) analysis over the effected areas indicate the presence of iron, suggesting that biological activity is taking place preferentially in paper areas containing iron

  8. Investigations of a Dual Seeded 1178 nm Raman Laser System

    Science.gov (United States)

    2016-01-14

    was obtained by Raman amplification of a distributed feedback diode laser in a variably strained polarization- maintaining fiber with a record-high...Calia, D.B., “50W CW visible laser source at 589 nm obtained via frequency doubling of three coherently combined narrow-band Raman fiber amplifiers...AFRL-RD-PS- TP-2016-0009 AFRL-RD-PS- TP-2016-0009 INVESTIGATIONS OF A DUAL SEEDED 1178 NM RAMAN LASER SYSTEM Leanne Henry, et al. 14 January

  9. Clock Gating Based Energy Efficient and Thermal Aware Design for Vedic Equation Solver on 28nm and 40nm FPGA

    DEFF Research Database (Denmark)

    Pandey, Bishwajeet; Pandey, Sujeet; Sharma, Shivani

    2016-01-01

    In this paper, we are integrating clock gating in design of energy efficient equation solver circuits based on Vedic mathematics. Clock gating is one of the best energy efficient techniques. The Sutra 'SunyamSamyasamuccaye' says thatif sum of numerator and sum of denominator is same then we can e......, 94.54% for 1800MHz, and 94.02% for 2.2GHz, when we use gated clock instead of un gated one on 40nm FPGA and temperature is 329.85K. Power consumption in 28nm FPGA is less than 40nm FPGA....

  10. Power scaling of laser diode pumped Pr3+:LiYF4 cw lasers: efficient laser operation at 522.6 nm, 545.9 nm, 607.2 nm, and 639.5 nm.

    Science.gov (United States)

    Gün, Teoman; Metz, Philip; Huber, Günter

    2011-03-15

    We report efficient cw laser operation of laser diode pumped Pr(3+)-doped LiYF4 crystals in the visible spectral region. Using two InGaN laser diodes emitting at λ(P)=443.9 nm with maximum output power of 1 W each and a 2.9-mm-long crystal with a doping concentration of 0.5%, output powers of 938 mW, 418 mW, 384 mW, and 773 mW were achieved for the laser wavelengths 639.5 nm, 607.2 nm, 545.9 nm, and 522.6 nm, respectively. The maximum absorbed pump powers were approximately 1.5 W, resulting in slope efficiencies of 63.6%, 32.0%, 52.1%, and 61.5%, as well as electro-optical efficiencies of 9.4%, 4.2%, 3.8%, and 7.7%, respectively. Within these experiments, laser diode-pumped laser action at 545.9 nm was demonstrated for what is believed to be the first time.

  11. Trends in nanosecond melanosome microcavitation up to 1540 nm

    Science.gov (United States)

    Schmidt, Morgan S.; Kennedy, Paul K.; Noojin, Gary D.; Vincelette, Rebecca L.; Thomas, Robert J.; Rockwell, Benjamin A.

    2015-09-01

    Thresholds for microcavitation of bovine and porcine melanosomes were previously reported, using single nanosecond (ns) laser pulses in the visible (532 nm) and the near-infrared (NIR) from 1000 to 1319 nm. Here, we report average radiant exposure thresholds for bovine melanosome microcavitation at additional NIR wavelengths up to 1540 nm, which range from ˜0.159 J/cm2 at 800 nm to 4.5 J/cm2 at 1540 nm. Melanosome absorption coefficients were also estimated, and decreased with increasing wavelength. These values were compared to retinal pigment epithelium coefficients, and to water absorption, over the same wavelength range. Corneal total intraocular energy retinal damage threshold values were estimated and compared to the previous (2007) and recently changed (2014) maximum permissible exposure (MPE) safe levels. Results provide additional data that support the recent changes to the MPE levels, as well as the first microcavitation data at 1540 nm, a wavelength for which melanosome microcavitation may be an ns-pulse skin damage mechanism.

  12. Site operations

    International Nuclear Information System (INIS)

    House, W.B.; Ebenhack, D.G.

    1989-01-01

    This chapter is a discussion of the management and operations practices used at the Barnwell Waste Management Facility in Barnwell, SC. The following topics are discussed: (1) Waste receiving and inspection, including manifest and certificates of compliance, radiological surveys, disposition of nonconforming items, and decontamination and disposition of secondary waste streams; (2) Waste disposal, including Title 10 CFR 61 requirements, disposal area evaluations, shipment offloading, container emplacement, and radiation protection; (3) Trench closure, including trench backfilling, trench capping, and permanent markers; (4) Site maintenance and stabilization, including trench maintenance, surface water management, and site closure activities; (5) Site monitoring programs, including operational monitoring, and environmental monitoring program; (6) Personnel training and qualifications, including basic training program, safety training program, special skills training, and physical qualifications; (7) Records management, including waste records, personnel training records, personnel dosimetry records, site monitoring records, trench qualification and construction records, and site drawings and stabilization records; (8) Site security; (9) Emergency response plans; and (10) Quality assurance

  13. Efficient continuous-wave 1112 nm Nd:YAG laser operation under direct diode pumping at 885 nm

    International Nuclear Information System (INIS)

    Gao, J; Dai, X J; Zhang, L; Wu, X D

    2013-01-01

    We report compact diode-end-pumped continuous-wave laser operation at 1112 nm under 885 nm diode-direct pumping for the first time. On the basis of the R 2 →Y 6 transition in a conventional Nd:YAG (yttrium aluminum garnet) single crystal, the maximum output power of 12.5 W is achieved, with an optical to optical efficiency of 46.6% and a slope efficiency of 52.9%. To the best of our knowledge, this represents the highest output at 1112 nm generated by a diode-end-pumped Nd:YAG laser. Furthermore, it is the highest optical to optical efficiency ever reported for 1112 nm Nd:YAG lasers. The short term power stability is ∼0.32% at 12.0 W output. (letter)

  14. Experimental Studies of Simultaneous 351 nm and 527 nm Laser Beam Interactions in a Long Scalelength Plasma

    International Nuclear Information System (INIS)

    Moody, J D; Divol, L; Glenzer, S H; MacKinnon, A J; Froula, D H; Gregori, G; Kruer, W L; Suter, L J; Williams, E A; Bahr, R; Seka, W

    2003-01-01

    We describe experiments investigating the simultaneous backscattering from 351 nm (3w) and 527 nm (2w) interaction beams in a long scalelength laser-produced plasma for intensities (le) 1 x 10 15 W/cm 2 . Measurements show comparable scattering fractions for both color probe beams. Time resolved spectra of stimulated Raman and Brillouin scattering (SRS and SBS) indicate the effects of laser intensity and smoothing as well as plasma composition and parameters on the scattering levels

  15. Absorption spectrum of DNA for wavelengths greater than 300 nm

    International Nuclear Information System (INIS)

    Sutherland, J.C.; Griffin, K.P.

    1981-01-01

    Although DNA absorption at wavelengths greater than 300 nm is much weaker than that at shorter wavelengths, this absorption seems to be responsible for much of the biological damage caused by solar radiation of wavelengths less than 320 nm. Accurate measurement of the absorption spectrum of DNA above 300 nm is complicated by turbidity characteristic of concentrated solutions of DNA. We have measured the absorption spectra of DNA from calf thymus, Clostridium perfringens, Escherichia coli, Micrococcus luteus, salmon testis, and human placenta using procedures which separate optical density due to true absorption from that due to turbidity. Above 300 nm, the relative absorption of DNA increases as a function of guanine-cytosine content, presumably because the absorption of guanine is much greater than the absorption of adenine at these wavelengths. This result suggests that the photophysical processes which follow absorption of a long-wavelength photon may, on the average, differ from those induced by shorter-wavelength photons. It may also explain the lower quantum yield for the killing of cells by wavelengths above 300 nm compared to that by shorter wavelengths

  16. 100-nm gate lithography for double-gate transistors

    Science.gov (United States)

    Krasnoperova, Azalia A.; Zhang, Ying; Babich, Inna V.; Treichler, John; Yoon, Jung H.; Guarini, Kathryn; Solomon, Paul M.

    2001-09-01

    The double gate field effect transistor (FET) is an exploratory device that promises certain performance advantages compared to traditional CMOS FETs. It can be scaled down further than the traditional devices because of the greater electrostatic control by the gates on the channel (about twice as short a channel length for the same gate oxide thickness), has steeper sub-threshold slope and about double the current for the same width. This paper presents lithographic results for double gate FET's developed at IBM's T. J. Watson Research Center. The device is built on bonded wafers with top and bottom gates self-aligned to each other. The channel is sandwiched between the top and bottom polysilicon gates and the gate length is defined using DUV lithography. An alternating phase shift mask was used to pattern gates with critical dimensions of 75 nm, 100 nm and 125 nm in photoresist. 50 nm gates in photoresist have also been patterned by 20% over-exposure of nominal 100 nm lines. No trim mask was needed because of a specific way the device was laid out. UV110 photoresist from Shipley on AR-3 antireflective layer were used. Process windows, developed and etched patterns are presented.

  17. Magnetic Nature of Light Transmission through a 5-nm Gap.

    Science.gov (United States)

    Yang, Hyosim; Kim, Dai-Sik; Kim, Richard H Joon-Yeon; Ahn, Jae Sung; Kang, Taehee; Jeong, Jeeyoon; Lee, Dukhyung

    2018-02-09

    Slot antennas have been exploited as important building blocks of optical magnetism because their radiations are invoked by the magnetic fields along the axes, as vectorial Babinet principle predicts. However, optical magnetism of a few-nanometer-width slit, for which fascinating applications are found due to the colossal field enhancement but Babinet principle fails due to the nonnegligible thickness, has not been investigated. In this paper, we demonstrated that the magnetic field plays a dominant role in light transmission through a 5-nm slit on a 150-nm-thick gold film. The 5-nm slit was fabricated by atomic layer lithography, and the transmission was investigated for various incident angles by experiment and simulation at 785-nm wavelength. We found that, due to the deep subwavelength gap width, the transmission has the same incident angle dependence as the tangential magnetic field on the metal surface and this magnetic nature of a nanogap holds up to ~100-nm width. Our analysis establishes conditions for nanogap optical magnetism and suggests new possibilities in realizing magnetic-field-driven optical nonlinearities.

  18. Prototyping the HPDP Chip on STM 65 NM Process

    Science.gov (United States)

    Papadas, C.; Dramitinos, G.; Syed, M.; Helfers, T.; Dedes, G.; Schoellkopf, J.-P.; Dugoujon, L.

    2011-08-01

    Currently Astrium GmbH is involved in the of the High Performance Data Processor (HPDP) development programme for telecommunication applications under a DLR contract. The HPDP project targets the implementation of the commercially available reconfigurable array processor IP (XPP from the company PACT XPP Technologies) in a radiation hardened technology.In the current complementary development phase funded under the Greek Industry Incentive scheme, it is planned to prototype the HPDP chip in commercial STM 65 nm technology. In addition it is also planned to utilise the preliminary radiation hardened components of this library wherever possible.This abstract gives an overview of the HPDP chip architecture, the basic details of the STM 65 nm process and the design flow foreseen for the prototyping. The paper will discuss the development and integration issues involved in using the STM 65 nm process (also including the available preliminary radiation hardened components) for designs targeted to be used in space applications.

  19. Large-scale lithography for sub-500nm features

    International Nuclear Information System (INIS)

    Pelzer, R L; Steininger, T; Belier, Benoit; Julie, Gwenaelle

    2006-01-01

    The interest in micro- and nanotechnologies has grown rapidly in the last years. The applications are versatile and different techniques found its way into several research domains as optics, electronics, magnetism, fluidics, etc. In all of these fields integration of more and more functions on steadily decreasing device dimensions lead to an increase in structural density and feature size. Expensive and slow processes utilizing projection steppers or e-beam direct writer equipment are used to fabricate nm features today. A high throughput and cost effective method adapted on a standard mask aligner will be demonstrated, making features of below 300nm available on wafer-level. We will demonstrate results of 4 different resists exposed on a DUV proximity aligner and plasma etched for optical and biological applications in the sub-300nm range

  20. Large-scale lithography for sub-500nm features

    Energy Technology Data Exchange (ETDEWEB)

    Pelzer, R L [Technology group, EV Group, DI Erich Thallner Str. 1, A-4780 Schaerding (Austria); Steininger, T [Technology group, EV Group, DI Erich Thallner Str. 1, A-4780 Schaerding (Austria); Belier, Benoit [CNRS, Institut d' Electronique Fondamentale, Universite Paris-Sud Bat 220, F- 91405 Orsay Cedex (France); Julie, Gwenaelle [CNRS, Institut d' Electronique Fondamentale, Universite Paris-Sud Bat 220, F- 91405 Orsay Cedex (France)

    2006-04-01

    The interest in micro- and nanotechnologies has grown rapidly in the last years. The applications are versatile and different techniques found its way into several research domains as optics, electronics, magnetism, fluidics, etc. In all of these fields integration of more and more functions on steadily decreasing device dimensions lead to an increase in structural density and feature size. Expensive and slow processes utilizing projection steppers or e-beam direct writer equipment are used to fabricate nm features today. A high throughput and cost effective method adapted on a standard mask aligner will be demonstrated, making features of below 300nm available on wafer-level. We will demonstrate results of 4 different resists exposed on a DUV proximity aligner and plasma etched for optical and biological applications in the sub-300nm range.

  1. 300 mm arrays and 30 nm Features: Frontiers in Sorting Biological Objects

    Science.gov (United States)

    Austin, Robert; Comella, Brandon; D'Silva, Joseph; Sturm, James

    2014-03-01

    One of the great challenges in prediction of metastasis is determining when the metastatic process actually begins. It is presumed that this process occurs due to passage of biological objects in the blood from tumor to remote sites. We will discuss our attempts to find both very large objects (circulating tumor cell clumps) and very small (exosomes) using a combination of extremely large scale photolithography on 300 mm wafers and deep-UV lithography to produce sub-100 nm arrays to sort exosomes. These technologies push the envelope of present day academic facilities . Supported by the National Science Foundation and the National Cancer Institute.

  2. [Cleavage of DNA fragments induced by UV nanosecond laser excitation at 193 nm].

    Science.gov (United States)

    Vtiurina, N N; Grokhovskiĭ, S L; Filimonov, I V; Medvedkov, O I; Nechipurenko, D Iu; Vasil'ev, S A; Nechipurenko, Iu D

    2011-01-01

    The cleavage of dsDNA fragments in aqueous solution after irradiation with UV laser pulses at 193 nm has been studied. Samples were investigated using polyacrylamide gel electrophoresis. The intensity of damage of particular phosphodiester bond after hot alkali treatment was shown to depend on the base pair sequence. It was established that the probability of cleavage is twice higher for sites of DNA containing two or more successively running guanine residues. A possible mechanism of damage to the DNA molecule connected with the migration of holes along the helix is discussed.

  3. Extreme Ultraviolet Process Optimization for Contact Layer of 14 nm Node Logic and 16 nm Half Pitch Memory Devices

    Science.gov (United States)

    Tseng, Shih-En; Chen, Alek

    2012-06-01

    Extreme ultraviolet (EUV) lithography is considered the most promising single exposure technology at the 27 nm half-pitch node and beyond. The imaging performance of ASML TWINSCAN NXE:3100 has been demonstrated to be able to resolve 26 nm Flash gate layer and 16 nm static random access memory (SRAM) metal layer with a 0.25 numerical aperture (NA) and conventional illumination. Targeting for high volume manufacturing, ASML TWINSCAN NXE:3300B, featuring a 0.33 NA lens with off-axis illumination, will generate a higher contrast aerial image due to improved diffraction order collection efficiency and is expected to reduce target dose via mask biasing. This work performed a simulation to determine how EUV high NA imaging benefits the mask rule check trade-offs required to achieve viable lithography solutions in two device application scenarios: a 14 nm node 6T-SRAM contact layer and a 16 nm half-pitch NAND Flash staggered contact layer. In each application, the three-dimensional mask effects versus Kirchhoff mask were also investigated.

  4. Superfund Sites

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This layer represents active Superfund Sites published by the Environmental Protection Agency (EPA). These data were extracted from the Superfund Enterprise...

  5. Site development

    International Nuclear Information System (INIS)

    Noack, J.

    1975-01-01

    The subject of this paper is a general view over all necessary considerations to develop the site after it has been chosen and before starting with the construction of a nuclear power plant. (orig./RW) [de

  6. Site selection

    International Nuclear Information System (INIS)

    Olsen, C.W.

    1983-07-01

    The conditions and criteria for selecting a site for a nuclear weapons test at the Nevada Test Site are summarized. Factors considered are: (1) scheduling of drill rigs, (2) scheduling of site preparation (dirt work, auger hole, surface casing, cementing), (3) schedule of event (when are drill hole data needed), (4) depth range of proposed W.P., (5) geologic structure (faults, Pz contact, etc.), (6) stratigraphy (alluvium, location of Grouse Canyon Tuff, etc.), (7) material properties (particularly montmorillonite and CO 2 content), (8) water table depth, (9) potential drilling problems (caving), (10) adjacent collapse craters and chimneys, (11) adjacent expended but uncollapsed sites, (12) adjacent post-shot or other small diameter holes, (13) adjacent stockpile emplacement holes, (14) adjacent planned events (including LANL), (15) projected needs of Test Program for various DOB's and operational separations, and (16) optimal use of NTS real estate

  7. On-chip measurements of Brownian relaxation of magnetic beads with diameters from 10 nm to 250 nm

    DEFF Research Database (Denmark)

    Østerberg, Frederik Westergaard; Rizzi, Giovanni; Hansen, Mikkel Fougt

    2013-01-01

    We demonstrate the use of planar Hall effect magnetoresistive sensors for AC susceptibility measurements of magnetic beads with frequencies ranging from DC to 1 MHz. This wide frequency range allows for measuring Brownian relaxation of magnetic beads with diameters ranging from 10 nm to 250 nm....... Brownian relaxation is measured for six different magnetic bead types and their hydrodynamic diameters are determined. The hydrodynamic diameters are found to be within 40% of the nominal bead diameters. We discuss the applicability of the different bead types for volume-based biosensing with respect...... to sedimentation, magnetic trapping, and signal per bead. Among the investigated beads, we conclude that the beads with a nominal diameter of 80 nm are best suited for future on-chip volume-based biosensing experiments using planar Hall effect sensors....

  8. FDML swept source at 1060 nm using a tapered amplifier

    DEFF Research Database (Denmark)

    Marschall, Sebastian; Klein, Thomas; Wieser, Wolfgang

    2010-01-01

    We present a novel frequency-swept light source working at 1060nm that utilizes a tapered amplifier as gain medium. These devices feature significantly higher saturation power than conventional semiconductor optical amplifiers and can thus improve the limited output power of swept sources in this...... an axial resolution of 15 µm in air (~11µm in tissue) for OCT applications can be achieved....

  9. A novel double patterning approach for 30nm dense holes

    Science.gov (United States)

    Hsu, Dennis Shu-Hao; Wang, Walter; Hsieh, Wei-Hsien; Huang, Chun-Yen; Wu, Wen-Bin; Shih, Chiang-Lin; Shih, Steven

    2011-04-01

    Double Patterning Technology (DPT) was commonly accepted as the major workhorse beyond water immersion lithography for sub-38nm half-pitch line patterning before the EUV production. For dense hole patterning, classical DPT employs self-aligned spacer deposition and uses the intersection of horizontal and vertical lines to define the desired hole patterns. However, the increase in manufacturing cost and process complexity is tremendous. Several innovative approaches have been proposed and experimented to address the manufacturing and technical challenges. A novel process of double patterned pillars combined image reverse will be proposed for the realization of low cost dense holes in 30nm node DRAM. The nature of pillar formation lithography provides much better optical contrast compared to the counterpart hole patterning with similar CD requirements. By the utilization of a reliable freezing process, double patterned pillars can be readily implemented. A novel image reverse process at the last stage defines the hole patterns with high fidelity. In this paper, several freezing processes for the construction of the double patterned pillars were tested and compared, and 30nm double patterning pillars were demonstrated successfully. A variety of different image reverse processes will be investigated and discussed for their pros and cons. An economic approach with the optimized lithography performance will be proposed for the application of 30nm DRAM node.

  10. Isolation and genomic characterization of Escherichia coli O157:NM ...

    African Journals Online (AJOL)

    Human diseases caused by Escherichia coli O157:NM and E. coli O157:H7 strains have been reported throughout the world. In developed countries, serotype O157:H7 represents the major cause of human diseases; however, there have been increasing reports of non-O157 Shiga toxin (Stx)-producing E. coli strains ...

  11. 78 FR 72141 - New Mexico Disaster Number NM-00037

    Science.gov (United States)

    2013-12-02

    ... SMALL BUSINESS ADMINISTRATION [Disaster Declaration 13787 and 13788] New Mexico Disaster Number NM... Mexico (FEMA-4148-DR), dated 09/30/2013. Incident: Severe Storms and Flooding Incident Period: 07/23/2013... INFORMATION: The notice of the President's major disaster declaration for Private Non-Profit organizations in...

  12. 76 FR 2431 - New Mexico Disaster #NM-00016

    Science.gov (United States)

    2011-01-13

    ... SMALL BUSINESS ADMINISTRATION [Disaster Declaration 12320 and 12321] New Mexico Disaster NM-00016... Presidential declaration of a major disaster for Public Assistance Only for the State of New Mexico (FEMA-1936... INFORMATION: The notice of the President's major disaster declaration for Private Non-Profit organizations in...

  13. 78 FR 73581 - New Mexico Disaster Number NM-00035

    Science.gov (United States)

    2013-12-06

    ... SMALL BUSINESS ADMINISTRATION [Disaster Declaration 13809 and 13810] New Mexico Disaster Number NM... Mexico (FEMA-4152-DR), dated 10/29/2013. Incident: Severe Storms, Flooding, and Mudslides. Incident... 20416. SUPPLEMENTARY INFORMATION: The notice of the President's major disaster declaration for Private...

  14. 77 FR 63409 - New Mexico Disaster Number NM-00029

    Science.gov (United States)

    2012-10-16

    ... SMALL BUSINESS ADMINISTRATION [Disaster Declaration 13252 and 13253] New Mexico Disaster Number NM... Mexico (FEMA-4079-DR), dated 08/24/2012. Incident: Flooding. Incident Period: 06/22/2012 through 07/12... the President's major disaster declaration for Private Non-Profit organizations in the State of NEW...

  15. 78 FR 66982 - New Mexico Disaster #NM-00035

    Science.gov (United States)

    2013-11-07

    ... SMALL BUSINESS ADMINISTRATION [Disaster Declaration 13809 and 13810] New Mexico Disaster NM-00035... declaration of a major disaster for Public Assistance Only for the State of New Mexico (FEMA- 4152-DR), dated... INFORMATION: Notice is hereby given that as a result of the President's major disaster declaration on 10/29...

  16. 76 FR 81553 - New Mexico Disaster Number NM-00024

    Science.gov (United States)

    2011-12-28

    ... SMALL BUSINESS ADMINISTRATION [Disaster Declaration 12940 and 12941] New Mexico Disaster Number NM... Mexico (FEMA-4047-DR), dated 11/23/2011. Incident: Flooding. Incident Period: 08/19/2011 through 08/24... INFORMATION: The notice of the President's major disaster declaration for Private Non-Profit organizations in...

  17. EST Table: NM_001043366 [KAIKOcDNA[Archive

    Lifescience Database Archive (English)

    Full Text Available NM_001043366 Sap-r 10/09/29 98 %/961 aa ref|NP_001036831.1| saposin-related [Bombyx... gnl|Amel|GB16561-PA 10/09/10 42 %/808 aa gi|91077504|ref|XP_966852.1| PREDICTED: similar to saposin isoform 1 [Tribolium castaneum] FS791050 ...

  18. 308-nm excimer laser for the treatment of alopecia areata.

    Science.gov (United States)

    Al-Mutairi, Nawaf

    2007-12-01

    Alopecia areata is loss of hair from localized or diffuse areas of hair-bearing area of the skin. Recently there are reports of efficacy of the 308-nm excimer radiation for this condition. To study the effect of the 308-nm excimer laser in the treatment of alopecia areata. Eighteen patients with 42 recalcitrant patches (including 1 adult with alopecia totalis) were enrolled in this study. The lesions were treated with the 308-nm excimer laser twice a week for a period of 12 weeks; one lesion on each patient was left as a control for comparison. There were 7 males and 11 females in this study. Regrowth of hair was observed in 17 (41.5%) patches. Thirteen of the 18 lesions in scalp showed a complete regrowth of hair. The extremity regions failed to show a response. Atopic diatheses had an unfavorable effect on the outcome in our patients. The 308-nm excimer laser is an effective therapeutic option for patchy alopecia areata of the scalp and for some cases with patchy alopecia areata of the beard area. It does not work for patchy alopecia areata of the extremities.

  19. Spectral narrowing of a 980 nm tapered diode laser bar

    Science.gov (United States)

    Vijayakumar, Deepak; Jensen, Ole Bjarlin; Lucas Leclin, Ga"lle; Petersen, Paul Michael; Thestrup, Birgitte

    2011-03-01

    High power diode laser bars are interesting in many applications such as solid state laser pumping, material processing, laser trapping, laser cooling and second harmonic generation. Often, the free running laser bars emit a broad spectrum of the order of several nanometres which limit their scope in wavelength specific applications and hence, it is vital to stabilize the emission spectrum of these devices. In our experiment, we describe the wavelength narrowing of a 12 element 980 nm tapered diode laser bar using a simple Littman configuration. The tapered laser bar which suffered from a big smile has been "smile corrected" using individual phase masks for each emitter. The external cavity consists of the laser bar, both fast and slow axis micro collimators, smile correcting phase mask, 6.5x beam expanding lens combination, a 1200 lines/mm reflecting grating with 85% efficiency in the first order, a slow axis focusing cylindrical lens of 40 mm focal length and an output coupler which is 10% reflective. In the free running mode, the laser emission spectrum was 5.5 nm wide at an operating current of 30A. The output power was measured to be in excess of 12W. Under the external cavity operation, the wavelength spread of the laser could be limited to 0.04 nm with an output power in excess of 8 W at an operating current of 30A. The spectrum was found to be tuneable in a range of 16 nm.

  20. Conjugated 12 nm long oligomers as molecular wires in nanoelectronics

    DEFF Research Database (Denmark)

    Søndergaard, Roar; Strobel, Sebastian; Bundgaard, Eva

    2009-01-01

    We demonstrate a generic synthetic approach to oligophenylenevinylene (OPV) derivative molecules with a molecular length of up to 12 nm and a relatively free choice of end group that can attach to different electrodes such as metallic gold or potentially transition metal oxide semiconductors. OPV...

  1. Magneto-optical trap for metastable helium at 389 nm

    NARCIS (Netherlands)

    Koelemeij, J.C.J.; Stas, R.J.W.; Hogervorst, W.; Vassen, W.

    2003-01-01

    We have constructed a magneto-optical trap (MOT) for metastable triplet helium atoms utilizing the 2 S-3(1)-->3 P-3(2) line at 389 nm as the trapping and cooling transition. The far-red-detuned MOT (detuning Delta=-41 MHz) typically contains few times 10(7) atoms at a relatively high (similar

  2. ILT optimization of EUV masks for sub-7nm lithography

    Science.gov (United States)

    Hooker, Kevin; Kuechler, Bernd; Kazarian, Aram; Xiao, Guangming; Lucas, Kevin

    2017-06-01

    The 5nm and 7nm technology nodes will continue recent scaling trends and will deliver significantly smaller minimum features, standard cell areas and SRAM cell areas vs. the 10nm node. There are tremendous economic pressures to shrink each subsequent technology, though in a cost-effective and performance enhancing manner. IC manufacturers are eagerly awaiting EUV so that they can more aggressively shrink their technology than they could by using complicated MPT. The current 0.33NA EUV tools and processes also have their patterning limitations. EUV scanner lenses, scanner sources, masks and resists are all relatively immature compared to the current lithography manufacturing baseline of 193i. For example, lens aberrations are currently several times larger (as a function of wavelength) in EUV scanners than for 193i scanners. Robustly patterning 16nm L/S fully random logic metal patterns and 40nm pitch random logic rectangular contacts with 0.33NA EUV are tough challenges that will benefit from advanced OPC/RET. For example, if an IC manufacturer can push single exposure device layer resolution 10% tighter using improved ILT to avoid using DPT, there will be a significant cost and process complexity benefit to doing so. ILT is well known to have considerable benefits in finding flexible 193i mask pattern solutions to improve process window, improve 2D CD control, improve resolution in low K1 lithography regime and help to delay the introduction of DPT. However, ILT has not previously been applied to EUV lithography. In this paper, we report on new developments which extend ILT method to EUV lithography and we characterize the benefits seen vs. traditional EUV OPC/RET methods.

  3. Treatment of oral lichen planus using 308-nm excimer laser.

    Science.gov (United States)

    Liu, Wei-Bing; Sun, Li-Wei; Yang, Hua; Wang, Yan-Fei

    2017-09-01

    Oral lichen planus (OLP) is a chronic inflammatory disease, has prolonged courses, repeated attacks and resistance to treatment. The traditional narrow spectrum UVB treatment has an established efficacy on skin lichen planus, and high safety. However, most of ultraviolet phototherapy devices have a huge volume, thereby cannot be used in the treatment of OLP. Lymphocytic infiltration is evident in the lesions of lichen planus, and the direct irradiation of 308-nm excimer laser can induce apoptosis of the T lymphocytes in skin lesions, thereby has a unique therapeutic effect on the diseases involving T lymphocytes. This study aims to investigate the efficacy of 308-nm excimer laser in the treatment of OLP. A total of six OLP patients were enrolled into this study, and further pathological diagnosis was conducted, then 308-nm excimer laser was used in the treatment. The efficacy of 308-nm excimer laser in the treatment of OLP was satisfactory. The clinical symptoms of five patients were significantly improved. In two patients, the erosion surface based on congestion and the surrounding white spots completely disappeared, and clinical recovery was achieved. Three patients achieved partial remission, that is, the erosion surface healed, congestion and white spot area shrunk by more than 1/2 of the primary skin lesions. In the remaining one patient, the erosion surface had not completely healed after treatment, and congestion and white spot area shrunk by less than 1/2 of the primary skin lesions. Only one patients had developed mild pain during the treatment, and this symptom alleviated by itself. The 308-nm excimer laser therapy can serve as a safe and effective treatment for OLP. © 2017 Wiley Periodicals, Inc.

  4. Effects of a 1,450 nm diode laser on facial sebum excretion.

    Science.gov (United States)

    Laubach, Hans-Joachim; Astner, Susanne; Watanabe, Kanna; Clifford, Joan; Rius-Diaz, Francisca; Zurakowski, David; Manstein, Dieter

    2009-02-01

    Laser therapy with a 1,450 nm diode laser is a clinically effective treatment for acne vulgaris, although the mechanism of action is unknown. To investigate this, we conducted a small, prospective, controlled clinical trial to assess this laser's effects on the facial sebum excretion rate (SER). Fourteen healthy volunteers without active acne were enrolled in this study and received three laser treatments on test areas of the nose and forehead. Nine subjects completed the treatment regimen and were available for follow-up. SER was measured with Sebumeter prior to the first treatment, and at 1 week and 1 month after the third treatment. Photographs were taken and subjective assessment of skin oiliness and pore size determined by questionnaires at 1 month follow-up. No significant reduction in SER was observed comparing treated with control on all treatment sites (P>0.05) on the nose. Reduction in the absolute SER was observed for both test and control sites on the forehead, reaching significance on the treatment site (P = 0.04) and marginal significance on the control site (P = 0.08). While our study was designed to detect only large changes in SER, we conclude that three 1,450 nm laser treatment sessions did not cause marked changes in SER compared to the control (i.e., >44%). Thus, major destruction of sebaceous glands as a result of this treatment is unlikely. However, reduced sebum production was observed on both treatment and control sides at 1 month. Therefore alternative mechanisms should also be considered to explain the clinical efficacy of this treatment for acne vulgaris. (c) 2009 Wiley-Liss, Inc.

  5. Site development

    International Nuclear Information System (INIS)

    Gaynor, R.K.

    1989-01-01

    Development of a low-level radioactive waste land disposal facility is little different than any industrial development of similar scope. Consideration must be made for normal business and operations management, security, facility maintenance, traffic control and necessary amenities for personnel. The item specific to the low-level waste site is the handling of radioactive waste materials and the regulatory and environmental protection procedures that must be planned for and accomodated in the site design and development. Each of these elements and the facility as a whole must be designed to be compatible with local land use plans, available transportation and support services, and the social and economic goals of the local community. Plans should also be made for quality control and orderly construction. This chapter deals with those aspects of the facility, its design and construction which are integral parts to the overall performance of the site

  6. Study of drain-extended NMOS under electrostatic discharge stress in 28 nm and 40 nm CMOS process

    Science.gov (United States)

    Wang, Weihuai; Jin, Hao; Dong, Shurong; Zhong, Lei; Han, Yan

    2016-02-01

    Researches on the electrostatic discharge (ESD) performance of drain-extended NMOS (DeNMOS) under the state-of-the-art 28 nm and 40 nm bulk CMOS process are performed in this paper. Three distinguishing phases of avalanche breakdown stage, depletion region push-out stage and parasitic NPN turn on stage of the gate-grounded DeNMOS (GG-DeNMOS) fabricated under 28 nm CMOS process measured with transmission line pulsing (TLP) test are analyzed through TCAD simulations and tape-out silicon verification detailedly. Damage mechanisms and failure spots of GG-DeNMOS under both CMOS processes are thermal breakdown of drain junction. Improvements based on the basic structure adjustments can increase the GG-DeNMOS robustness from original 2.87 mA/μm to the highest 5.41 mA/μm. Under 40 nm process, parameter adjustments based on the basic structure have no significant benefits on the robustness improvements. By inserting P+ segments in the N+ implantation of drain or an entire P+ strip between the N+ implantation of drain and polysilicon gate to form the typical DeMOS-SCR (silicon-controlled rectifier) structure, the ESD robustness can be enhanced from 1.83 mA/μm to 8.79 mA/μm and 29.78 mA/μm, respectively.

  7. Cryogenic Lifetime Studies of 130 nm and 65 nm CMOS Technologies for High-Energy Physics Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Hoff, James R. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Deptuch, G. W. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Wu, Guoying [Southern Methodist Univ., Dallas, TX (United States); Gui, Ping [Southern Methodist Univ., Dallas, TX (United States)

    2015-06-04

    The Long Baseline Neutrino Facility intends to use unprecedented volumes of liquid argon to fill a time projection chamber in an underground facility. Research is under way to place the electronics inside the cryostat. For reasons of efficiency and economics, the lifetimes of these circuits must be well in excess of 20 years. The principle mechanism for lifetime degradation of MOSFET devices and circuits operating at cryogenic temperatures is hot carrier degradation. Choosing a process technology that is, as much as possible, immune to such degradation and developing design techniques to avoid exposure to such damage are the goals. This, then, requires careful investigation and a basic understanding of the mechanisms that underlie hot carrier degradation and the secondary effects they cause in circuits. In this work, commercially available 130 nm and 65 nm nMOS transistors operating at cryogenic temperatures are investigated. Our results show that both technologies achieve the lifetimes required by the experiment. Minimal design changes are necessary in the case of the 130 nm process and no changes whatsoever are necessary for the 65 nm process.

  8. Probing the diffusion of vacuum ultraviolet ({lambda} = 172 nm) induced oxidants by nanoparticles immobilization

    Energy Technology Data Exchange (ETDEWEB)

    Khatri, Om P.; Hatanaka, Takeshi; Murase, Kuniaki [Department of Materials Science and Engineering, Kyoto University, Sakyo-ku, Kyoto 606-8501 (Japan); Sugimura, Hiroyuki, E-mail: hiroyuki.sugimura@materials.mbox.media.kyoto-u.ac.jp [Department of Materials Science and Engineering, Kyoto University, Sakyo-ku, Kyoto 606-8501 (Japan)

    2009-09-30

    Vacuum ultraviolet (VUV, {lambda} = 172 nm) patterning of alkyl monolayer on silicon surface has been demonstrated with emphasis on the diffusion of VUV induced oxygen-derived active species, which are accountable for the pattern broadening. The VUV photons photo-dissociates the atmospheric oxygen and water molecules into the oxygen-derived active species (oxidants). These oxidants photo-oxidize the hexadecyl (HD) monolayer in VUV irradiated regions (Khatri et al., Langmuir. 24 (2008) 12077), as well as the little concentration of oxidants diffuses towards the masked areas. In this study, we performed VUV patterning at a vacuum pressure of 10 Pa to track the diffusion pathways for the oxidants with help of gold nanoparticles (AuNPs; {phi} = 10 nm) immobilization. At VUV irradiated sites AuNPs are found as uniformly distributed, but adjacent to the pattern boundary we observed quasi-linear arrays of AuNPs, which are determined by diffusion pathways of the oxidants. The diffusion of oxidants plays vital role in pattern broadening. The site selective anchoring of AuNPs demonstrates the utility of VUV photons for the construction of functional materials with microstructural architecture.

  9. Site Practice

    DEFF Research Database (Denmark)

    Wahedi, Haseebullah

    2016-01-01

    different practices in the construction phase. The research is based on an ethnographic study of a case in Denmark. The empirical data were collected through direct observations and semi-structured interviews with site managers, contract managers, foremen and craftsmen. Findings revealed...... that the construction phase comprises several communities and practices, leading to various uses of the drawings. The results indicated that the craftsmen used drawings to position themselves in the correct location, and that the site managers and contract managers used them as management tools and legal documents...

  10. CALIPSO lidar calibration at 532 nm: version 4 nighttime algorithm

    Science.gov (United States)

    Kar, Jayanta; Vaughan, Mark A.; Lee, Kam-Pui; Tackett, Jason L.; Avery, Melody A.; Garnier, Anne; Getzewich, Brian J.; Hunt, William H.; Josset, Damien; Liu, Zhaoyan; Lucker, Patricia L.; Magill, Brian; Omar, Ali H.; Pelon, Jacques; Rogers, Raymond R.; Toth, Travis D.; Trepte, Charles R.; Vernier, Jean-Paul; Winker, David M.; Young, Stuart A.

    2018-03-01

    Data products from the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) on board Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) were recently updated following the implementation of new (version 4) calibration algorithms for all of the Level 1 attenuated backscatter measurements. In this work we present the motivation for and the implementation of the version 4 nighttime 532 nm parallel channel calibration. The nighttime 532 nm calibration is the most fundamental calibration of CALIOP data, since all of CALIOP's other radiometric calibration procedures - i.e., the 532 nm daytime calibration and the 1064 nm calibrations during both nighttime and daytime - depend either directly or indirectly on the 532 nm nighttime calibration. The accuracy of the 532 nm nighttime calibration has been significantly improved by raising the molecular normalization altitude from 30-34 km to the upper possible signal acquisition range of 36-39 km to substantially reduce stratospheric aerosol contamination. Due to the greatly reduced molecular number density and consequently reduced signal-to-noise ratio (SNR) at these higher altitudes, the signal is now averaged over a larger number of samples using data from multiple adjacent granules. Additionally, an enhanced strategy for filtering the radiation-induced noise from high-energy particles was adopted. Further, the meteorological model used in the earlier versions has been replaced by the improved Modern-Era Retrospective analysis for Research and Applications, Version 2 (MERRA-2), model. An aerosol scattering ratio of 1.01 ± 0.01 is now explicitly used for the calibration altitude. These modifications lead to globally revised calibration coefficients which are, on average, 2-3 % lower than in previous data releases. Further, the new calibration procedure is shown to eliminate biases at high altitudes that were present in earlier versions and consequently leads to an improved representation of

  11. Chemical vapour deposition of freestanding sub-60 nm graphene gyroids

    Science.gov (United States)

    Cebo, Tomasz; Aria, Adrianus I.; Dolan, James A.; Weatherup, Robert S.; Nakanishi, Kenichi; Kidambi, Piran R.; Divitini, Giorgio; Ducati, Caterina; Steiner, Ullrich; Hofmann, Stephan

    2017-12-01

    The direct chemical vapour deposition of freestanding graphene gyroids with controlled sub-60 nm unit cell sizes is demonstrated. Three-dimensional (3D) nickel templates were fabricated through electrodeposition into a selectively voided triblock terpolymer. The high temperature instability of sub-micron unit cell structures was effectively addressed through the early introduction of the carbon precursor, which stabilizes the metallized gyroidal templates. The as-grown graphene gyroids are self-supporting and can be transferred onto a variety of substrates. Furthermore, they represent the smallest free standing periodic graphene 3D structures yet produced with a pore size of tens of nm, as analysed by electron microscopy and optical spectroscopy. We discuss generality of our methodology for the synthesis of other types of nanoscale, 3D graphene assemblies, and the transferability of this approach to other 2D materials.

  12. Single, composite, and ceramic Nd:YAG 946-nm lasers

    Science.gov (United States)

    Lan, Rui-Jun; Yang, Guang; Zheng-Ping, Wang

    2015-06-01

    Single, composite crystal and ceramic continuous wave (CW) 946-nm Nd:YAG lasers are demonstrated, respectively. The ceramic laser behaves better than the crystal laser. With 5-mm long ceramic, a CW output power of 1.46 W is generated with an optical conversion efficiency of 13.9%, while the slope efficiency is 17.9%. The optimal ceramic length for a 946-nm laser is also calculated. Project supported by the National Natural Science Foundation of China (Grant No. 61405171), the Natural Science Foundation of Shandong Province, China (Grant No. ZR2012FQ014), and the Science and Technology Program of the Shandong Higher Education Institutions of China (Grant No. J13LJ05).

  13. Blue laser diode (450 nm) systems for welding copper

    Science.gov (United States)

    Silva Sa, M.; Finuf, M.; Fritz, R.; Tucker, J.; Pelaprat, J.-M.; Zediker, M. S.

    2018-02-01

    This paper will discuss the development of high power blue laser systems for industrial applications. The key development enabling high power blue laser systems is the emergence of high power, high brightness laser diodes at 450 nm. These devices have a high individual brightness rivaling their IR counterparts and they have the potential to exceed their performance and price barriers. They also have a very high To resulting in a 0.04 nm/°C wavelength shift. They have a very stable lateral far-field profile which can be combined with other diodes to achieve a superior brightness. This paper will report on the characteristics of the blue laser diodes, their integration into a modular laser system suitable for scaling the output power to the 1 kW level and beyond. Test results will be presented for welding of copper with power levels ranging from 150 Watts to 600 Watts

  14. Site selection

    CERN Multimedia

    CERN PhotoLab

    1968-01-01

    To help resolve the problem of site selection for the proposed 300 GeV machine, the Council selected "three wise men" (left to right, J H Bannier of the Netherlands, A Chavanne of Switzerland and L K Boggild of Denmark).

  15. Site Restoration

    Energy Technology Data Exchange (ETDEWEB)

    Noynaert, L.; Bruggeman, A.; Cornelissen, R.; Massaut, V.; Rahier, A

    2001-04-01

    The objectives, the programme, and the achievements of the Site Restoration Department of SCK-CEN in 2000 are summarised. Main activities include the decommissioning of the BR3 PWR-reactor as well as other clean-up activities, projects on waste minimisation and activities related to the management of decommissioning projects. The department provides consultancy and services to external organisations.

  16. Site Restoration

    International Nuclear Information System (INIS)

    Noynaert, L.; Bruggeman, A.; Cornelissen, R.; Massaut, V.; Rahier, A.

    2001-01-01

    The objectives, the programme, and the achievements of the Site Restoration Department of SCK-CEN in 2000 are summarised. Main activities include the decommissioning of the BR3 PWR-reactor as well as other clean-up activities, projects on waste minimisation and activities related to the management of decommissioning projects. The department provides consultancy and services to external organisations

  17. Photodissociation of the OD radical at 226 and 243 nm

    International Nuclear Information System (INIS)

    Radenovic, Dragana C.; Roij, Andre J.A. van; Chestakov, Dmitri A.; Eppink, Andre T.J.B.; Meulen, J.J. ter; Parker, David H.; Loo, Mark P.J. van der; Groenenboom, Gerrit C.; Greenslade, Margaret E.; Lester, Marsha I.

    2003-01-01

    The photodissociation dynamics of state selected OD radicals has been examined at 243 and 226 nm using velocity map imaging to probe the angle-speed distributions of the D( 2 S) and O( 3 P 2 ) products. Both experiment and complementary first principle calculations demonstrate that photodissociation occurs by promotion of OD from high vibrational levels of the ground X 2 Π state to the repulsive 1 2 Σ - state

  18. Writable and erasable PPV medium by irradiation at 365 nm

    Energy Technology Data Exchange (ETDEWEB)

    Mochizuki, Hiroyuki [Photonics Research Institutes, National Institute of Advanced Industrial Science and Technology, 1-8-31 Midorigaoka, Ikeda, Osaka 563-8577 (Japan)], E-mail: h-mochizuki@aist.go.jp; Mizokuro, Toshiko; Tanigaki, Nobutaka; Hiraga, Takashi [Photonics Research Institutes, National Institute of Advanced Industrial Science and Technology, 1-8-31 Midorigaoka, Ikeda, Osaka 563-8577 (Japan)

    2008-03-03

    Dopings of vaporized cis-1,2-dicyano-1,2-bis(2,4,5-trimethyl-3-thienyl) ethane (CMTE) into poly(methyl methacrylate) (PMMA), polystyrene, and polycarbonate were performed by a vacuum process, and the doping behaviors of CMTE were evaluated. Among the matrix polymers, PMMA was dispersed CMTE densely in its surface region. By using the CMTE-doped PMMA, we could fabricate a novel rewritable medium: a multi-layered film was prepared from over-coating of CMTE-doped PMMA onto poly(p-phenylene vinylene) (PPV) film, which set on a transparent substrate. Image storage could be performed upon irradiation at 365 nm at the side of CMTE/PMMA layer: color of the irradiated area changed a light yellow to a red due to photo-isomerization of CMTE. Next, upon irradiation at 365 nm at the side of the transparent substrate, PPV emitted a green fluorescence at around 530 nm, and the CMTE absorbed the emission from PPV causing image-erasure based on back-isomerization of CMTE.

  19. Advanced CMOS device technologies for 45 nm node and below

    Directory of Open Access Journals (Sweden)

    A. Veloso, T. Hoffmann, A. Lauwers, H. Yu, S. Severi, E. Augendre, S. Kubicek, P. Verheyen, N. Collaert, P. Absil, M. Jurczak and S. Biesemans

    2007-01-01

    Full Text Available We review and discuss the latest developments and technology options for 45 nm node and below, with scaled planar bulk MOSFETs and MuGFETs as emerging devices. One of the main metal gate (MG candidates for scaled CMOS technologies are fully silicided (FUSI gates. In this work, by means of a selective and controlled poly etch-back integration process, dual work-function Ni-based FUSI/HfSiON CMOS circuits with record ring oscillator performance (high-VT are reported (17 ps at VDD=1.1 V and 20 pA/μm Ioff, meeting the ITRS 45 nm node requirement for low-power (LP CMOS. Compatibility of FUSI and other MG with known stress boosters like stressed CESL (contact-etch-stop-layer with high intrinsic stress or embedded SiGe in the pMOS S/D regions is validated. To obtain MuGFET devices that are competitive, as compared to conventional planar bulk devices, and that meet the stringent drive and leakage current requirements for the 32 nm node and beyond, higher channel mobilities are required. Results obtained by several strain engineering methods are presented here.

  20. Water line positions in the 782–840 nm region

    International Nuclear Information System (INIS)

    Hu, S.-M.; Chen, B.; Tan, Y.; Wang, J.; Cheng, C.-F.; Liu, A.-W.

    2015-01-01

    A set of water transitions in the 782–840 nm region, including 38 H 2 16 O lines, 12 HD 16 O lines, and 30 D 2 16 O lines, were recorded with a cavity ring-down spectrometer calibrated using precise atomic lines. Absolute frequencies of the lines were determined with an accuracy of about 5 MHz. Systematic shifts were found in the line positions given in the HITRAN database and the upper energy levels given in recent MARVEL studies. - Highlights: • Cavity ring-down spectra of H 2 16 O, HD 16 O, and D 2 16 O lines in the 782–840 nm region were measured. • Absolute line positions of 80 water lines were determined with an accuracy of about 5 MHz. • The H 2 16 O positions given in HITRAN have a systematic shift of 0.001 cm −1 in the 796–840 nm region. • MARVEL D 2 16 O energies have a systematic deviation of about −0.008 cm −1

  1. Cultured Human Fibroblast Biostimulation Using a 940 nm Diode Laser

    Science.gov (United States)

    Illescas-Montes, Rebeca; Melguizo-Rodríguez, Lucía; Manzano-Moreno, Francisco Javier; García-Martínez, Olga; Ruiz, Concepción

    2017-01-01

    Background: Fibroblasts are the main cells involved in regeneration during wound healing. The objective was to determine the effect of 940 nm diode laser on cultured human fibroblasts using different irradiation regimens. Methods: The CCD-1064Sk human epithelial fibroblast cell line was treated with a 940 nm diode laser at different energy doses (power: 0.2–1 W and energy density: 1–7 J/cm2) using different transmission modes (continuous or pulsed). The effect on cell growth at 24 and 72 h post-treatment was examined by measuring the proliferative capacity, the impact on the cell cycle, and the effect on cell differentiation. Results: fibroblast proliferative capacity was increased at 24 and 72 h post-treatment as a function of the energy dose. The greatest increase was observed with a power of 0.2 or 0.5 W and energy density between 1 and 4 J/cm2; no difference was observed between continuous and pulsed modes. There were no significant differences in cell cycle between treated groups and controls. α-actin expression was increased by treatment, indicating enhanced cell differentiation. Conclusion: The 940 nm diode laser has biostimulating effects on fibroblasts, stimulating proliferative capacity and cell differentiation without altering the cell cycle. Further researches are necessary to explore its potential clinical usefulness in wound healing. PMID:28773152

  2. Photoacoustic imaging at 1064nm wavelength with exogenous contrast agents

    Science.gov (United States)

    Upputuri, Paul Kumar; Jiang, Yuyan; Pu, Kanyi; Pramanik, Manojit

    2018-02-01

    Photoacoustic (PA) imaging is a promising imaging modality for both preclinical research and clinical practices. Laser wavelengths in the first near infrared window (NIR-I, 650-950 nm) have been widely used for photoacoustic imaging. As compared with NIR-I window, scattering of photons by biological tissues is largely reduced in the second NIR (NIR-II) window, leading to enhanced imaging fidelity. However, the lack of biocompatible NIR-II absorbing exogenous agents prevented the use of this window for in vivo imaging. In recent years, few studies have been reported on photoacoustic imaging in NIR-II window using exogenous contrast agents. In this work, we discuss the recent work on PA imaging using 1064 nm wavelength, the fundamental of Nd:YAG laser, as an excitation wavelength. The PA imaging at 1064 nm is advantageous because of the low and homogeneous signal from tissue background, enabling high contrast in PA imaging when NIR-II absorbing contrast agents are employed.

  3. Ion transport in sub-5-nm graphene nanopores

    International Nuclear Information System (INIS)

    Suk, Myung E.; Aluru, N. R.

    2014-01-01

    Graphene nanopore is a promising device for single molecule sensing, including DNA bases, as its single atom thickness provides high spatial resolution. To attain high sensitivity, the size of the molecule should be comparable to the pore diameter. However, when the pore diameter approaches the size of the molecule, ion properties and dynamics may deviate from the bulk values and continuum analysis may not be accurate. In this paper, we investigate the static and dynamic properties of ions with and without an external voltage drop in sub-5-nm graphene nanopores using molecular dynamics simulations. Ion concentration in graphene nanopores sharply drops from the bulk concentration when the pore radius is smaller than 0.9 nm. Ion mobility in the pore is also smaller than bulk ion mobility due to the layered liquid structure in the pore-axial direction. Our results show that a continuum analysis can be appropriate when the pore radius is larger than 0.9 nm if pore conductivity is properly defined. Since many applications of graphene nanopores, such as DNA and protein sensing, involve ion transport, the results presented here will be useful not only in understanding the behavior of ion transport but also in designing bio-molecular sensors

  4. Advances in 193 nm excimer lasers for mass spectrometry applications

    Science.gov (United States)

    Delmdahl, Ralph; Esser, Hans-Gerd; Bonati, Guido

    2016-03-01

    Ongoing progress in mass analysis applications such as laser ablation inductively coupled mass spectrometry of solid samples and ultraviolet photoionization mediated sequencing of peptides and proteins is to a large extent driven by ultrashort wavelength excimer lasers at 193 nm. This paper will introduce the latest improvements achieved in the development of compact high repetition rate excimer lasers and elaborate on the impact on mass spectrometry instrumentation. Various performance and lifetime measurements obtained in a long-term endurance test over the course of 18 months will be shown and discussed in view of the laser source requirements of different mass spectrometry tasks. These sampling type applications are served by excimer lasers delivering pulsed 193 nm output of several mJ as well as fast repetition rates which are already approaching one Kilohertz. In order to open up the pathway from the laboratory to broader market industrial use, sufficient component lifetimes and long-term stable performance behavior have to be ensured. The obtained long-term results which will be presented are based on diverse 193 nm excimer laser tube improvements aiming at e.g. optimizing the gas flow dynamics and have extended the operational life the laser tube for the first time over several billion pulses even under high duty-cycle conditions.

  5. Cultured Human Fibroblast Biostimulation Using a 940 nm Diode Laser

    Directory of Open Access Journals (Sweden)

    Rebeca Illescas-Montes

    2017-07-01

    Full Text Available Background: Fibroblasts are the main cells involved in regeneration during wound healing. The objective was to determine the effect of 940 nm diode laser on cultured human fibroblasts using different irradiation regimens. Methods: The CCD-1064Sk human epithelial fibroblast cell line was treated with a 940 nm diode laser at different energy doses (power: 0.2–1 W and energy density: 1–7 J/cm2 using different transmission modes (continuous or pulsed. The effect on cell growth at 24 and 72 h post-treatment was examined by measuring the proliferative capacity, the impact on the cell cycle, and the effect on cell differentiation. Results: fibroblast proliferative capacity was increased at 24 and 72 h post-treatment as a function of the energy dose. The greatest increase was observed with a power of 0.2 or 0.5 W and energy density between 1 and 4 J/cm2; no difference was observed between continuous and pulsed modes. There were no significant differences in cell cycle between treated groups and controls. α-actin expression was increased by treatment, indicating enhanced cell differentiation. Conclusion: The 940 nm diode laser has biostimulating effects on fibroblasts, stimulating proliferative capacity and cell differentiation without altering the cell cycle. Further researches are necessary to explore its potential clinical usefulness in wound healing.

  6. A reflectivity profilometer for the optical characterisation of graded reflectivity mirrors in the 250 nm - 1100 nm spectral region

    International Nuclear Information System (INIS)

    Colucci, Alessandro; Nichelatti, Enrico

    1998-04-01

    It's developed the prototype of an instrument that can be used for the optical characterisation of graded reflectivity mirrors at any wavelength in the spectral region from 250 nm to 1100 nm. The instrument utilises a high-pressure Xe arc lamp as light source. Light is spectrally filtered by means of a grating monochromator. The sample is illuminated with an image of the monochromator exit slit. After reflection from the sample, this image is projected onto a 1024-elements charge-coupled device linear array driven by a digital frame board and interfaced with a personal computer. It's tested the instrument accuracy by comparing measurement results with the corresponding ones obtained by means of a laser scanning technique. Measurement Rms repeatability has been estimated to be approximately of 0.8% [it

  7. Combined fractional resurfacing (10600 nm/1540 nm): Tridimensional imaging evaluation of a new device for skin rejuvenation.

    Science.gov (United States)

    Mezzana, Paolo; Valeriani, Maurizio; Valeriani, Roberto

    2016-11-01

    In this study were described the results, by tridimensional imaging evaluation, of the new "Combined Fractional Resurfacing" technique with the first fractional laser that overtakes the limits of traditional ablative, nonablative fractional resurfacing by combining CO 2 ablative and GaAs nonablative lasers. These two wavelengths can work separately or in a mixed modality to give the best treatment choice to all the patients. In this study, it is demonstrated that the simultaneous combination of the CO 2 wavelength (10600 nm) and GaAs wavelength (1540 nm) reduced the downtime, reduced pain during the treatment, and produced better results on fine wrinkles reduction and almost the same results on pigmentation as seen with 3D analysis by Antera (Miravex).

  8. Paranode Abnormalities and Oxidative Stress in Optic Nerve Vulnerable to Secondary Degeneration: Modulation by 670 nm Light Treatment.

    Directory of Open Access Journals (Sweden)

    Charis R Szymanski

    Full Text Available Secondary degeneration of nerve tissue adjacent to a traumatic injury results in further loss of neurons, glia and function, via mechanisms that may involve oxidative stress. However, changes in indicators of oxidative stress have not yet been demonstrated in oligodendrocytes vulnerable to secondary degeneration in vivo. We show increases in the oxidative stress indicator carboxymethyl lysine at days 1 and 3 after injury in oligodendrocytes vulnerable to secondary degeneration. Dihydroethidium staining for superoxide is reduced, indicating endogenous control of this particular reactive species after injury. Concurrently, node of Ranvier/paranode complexes are altered, with significant lengthening of the paranodal gap and paranode as well as paranode disorganisation. Therapeutic administration of 670 nm light is thought to improve oxidative metabolism via mechanisms that may include increased activity of cytochrome c oxidase. Here, we show that light at 670 nm, delivered for 30 minutes per day, results in in vivo increases in cytochrome c oxidase activity co-localised with oligodendrocytes. Short term (1 day 670 nm light treatment is associated with reductions in reactive species at the injury site. In optic nerve vulnerable to secondary degeneration superoxide in oligodendrocytes is reduced relative to handling controls, and is associated with reduced paranode abnormalities. Long term (3 month administration of 670 nm light preserves retinal ganglion cells vulnerable to secondary degeneration and maintains visual function, as assessed by the optokinetic nystagmus visual reflex. Light at a wavelength of 670 nm may serve as a therapeutic intervention for treatment of secondary degeneration following neurotrauma.

  9. A reflectivity profilometer for the optical characterisation of grade reflectivity mirrors in the 250 nm - 1100 nm spectral region

    Energy Technology Data Exchange (ETDEWEB)

    Colucci, Alessandro; Nichelatti, Enrico [ENEA, Centro Ricerche Casaccia, Rome (Italy). Dipt. Innovazione

    1998-04-01

    It`s developed the prototype of an instrument that can be used for the optical characterisation of graded reflectivity mirrors at any wavelength in the spectral region from 250 nm to 1100 nm. The instrument utilises a high-pressure Xe arc lamp as light source. Light is spectrally filtered by means of a grating monochromator. The sample is illuminated with an image of the monochromator exit slit. After reflection from the sample, this image is projected onto a 1024-elements charge-coupled device linear array driven by a digital frame board and interfaced with a personal computer. It`s tested the instrument accuracy by comparing measurement results with the corresponding ones obtained by means of a laser scanning technique. Measurement Rms repeatability has been estimated to be approximately of 0.8%. [Italiano] E` stato sviluppato il prototipo di uno strumento per la catatterizzazione ottica di specchi a riflettivita` variabile, operante a qualsiasi lunghezza d`onda nell`intervallo spettrale da 250 nm a 1100 nm. La sorgente dello strumento e` una lampada ad arco allo Xenon ad alta pressione. La luce e` filtrata spettralmente per mezzo di un monocromatore a reticolo. Il campione viene illuminato da un`immagine della fenditura d`uscita del monocromatore. Dopo essere stata riflessa dal campione, questa immagine viene proiettata su un array CCD lineare a 1024 elementi, connesso elettronicamente a una scheda digitale e interfacciato a un personal computer. L`accuratezza dello strumento e` stata verificata confrontando alcune misure con le corrispondenti misure ottenute mediante una tecnica a scansione laser. La ripetibilita` RMS delle misure e` stata stimata essere circa dello 0.8%.

  10. Mechanistic comparison of pulse laser induced phase separation of particulates from cellulose paper at 213 nm and 532 nm

    Energy Technology Data Exchange (ETDEWEB)

    Arif, S.; Forster, M.; Kautek, W. [University of Vienna, Department of Physical Chemistry, Wien (Austria); Bushuk, S.; Kouzmouk, A.; Tatur, H.; Batishche, S. [National Academy of Sciences of the Republic of Belarus, Institute of Physics, Minsk (Belarus)

    2013-02-15

    The laser-induced phase separation of charcoal particles on additive-free cotton linters cellulose paper was investigated by electron and optical microscopy, colorimetry, and diffuse reflectance FT-IR. The fibre bundles were vaporised in depth of several 10 {mu}m above destruction fluence thresholds using visible 532 nm radiation. This is in contrast to mid-ultraviolet 213 nm radiation, where only the top fibre bundles were modified and partially evaporated. The colorimetric lightness results generally represented the cleaning status, whereas the colorimetric yellowing data represented irreversible chemical and/or photochemical changes. Charcoal-contaminated paper treated with visible and mid-ultraviolet radiation exhibited yellowing, whereas uncontaminated did not. This suggests that the electron-rich plasma generated by the evaporation of the particles heats the adjacent substrate and also excludes oxygen. Mid-ultraviolet, in contrast to visible radiation, shows particle removal always accompanied by paper destruction. IR spectroscopy results suggest cross-linking by ether bonds near the destruction threshold, but do not prove the formation of oxidation products and double bonds as the basis of the yellowing. A ''cleaning window'' between the cleaning threshold (0.1 J/cm{sup 2}) and the paper destruction threshold (2.9 J/cm{sup 2}) with a pulse number of 2 is provided by visible 532 nm laser treatment. (orig.)

  11. Mechanistic comparison of pulse laser induced phase separation of particulates from cellulose paper at 213 nm and 532 nm

    International Nuclear Information System (INIS)

    Arif, S.; Forster, M.; Kautek, W.; Bushuk, S.; Kouzmouk, A.; Tatur, H.; Batishche, S.

    2013-01-01

    The laser-induced phase separation of charcoal particles on additive-free cotton linters cellulose paper was investigated by electron and optical microscopy, colorimetry, and diffuse reflectance FT-IR. The fibre bundles were vaporised in depth of several 10 μm above destruction fluence thresholds using visible 532 nm radiation. This is in contrast to mid-ultraviolet 213 nm radiation, where only the top fibre bundles were modified and partially evaporated. The colorimetric lightness results generally represented the cleaning status, whereas the colorimetric yellowing data represented irreversible chemical and/or photochemical changes. Charcoal-contaminated paper treated with visible and mid-ultraviolet radiation exhibited yellowing, whereas uncontaminated did not. This suggests that the electron-rich plasma generated by the evaporation of the particles heats the adjacent substrate and also excludes oxygen. Mid-ultraviolet, in contrast to visible radiation, shows particle removal always accompanied by paper destruction. IR spectroscopy results suggest cross-linking by ether bonds near the destruction threshold, but do not prove the formation of oxidation products and double bonds as the basis of the yellowing. A ''cleaning window'' between the cleaning threshold (0.1 J/cm 2 ) and the paper destruction threshold (2.9 J/cm 2 ) with a pulse number of 2 is provided by visible 532 nm laser treatment. (orig.)

  12. Intra-cavity upconversion to 631 nm of images illuminated by an eye-safe ASE source at 1550 nm.

    Science.gov (United States)

    Torregrosa, A J; Maestre, H; Capmany, J

    2015-11-15

    We report an image wavelength upconversion system. The system mixes an incoming image at around 1550 nm (eye-safe region) illuminated by an amplified spontaneous emission (ASE) fiber source with a Gaussian beam at 1064 nm generated in a continuous-wave diode-pumped Nd(3+):GdVO(4) laser. Mixing takes place in a periodically poled lithium niobate (PPLN) crystal placed intra-cavity. The upconverted image obtained by sum-frequency mixing falls around the 631 nm red spectral region, well within the spectral response of standard silicon focal plane array bi-dimensional sensors, commonly used in charge-coupled device (CCD) or complementary metal-oxide-semiconductor (CMOS) video cameras, and of most image intensifiers. The use of ASE illumination benefits from a noticeable increase in the field of view (FOV) that can be upconverted with regard to using coherent laser illumination. The upconverted power allows us to capture real-time video in a standard nonintensified CCD camera.

  13. 5.5nm wavelength-tunable high-power MOPA diode laser system at 971 nm

    Science.gov (United States)

    Tawfieq, Mahmoud; Müller, André; Fricke, Jörg; Della Casa, Pietro; Ressel, Peter; Ginolas, Arnim; Feise, David; Sumpf, Bernd; Tränkle, Günther

    2018-02-01

    In this work, a widely tunable hybrid master oscillator power amplifier (MOPA) diode laser with 6.2 W of output power at 971.8 nm will be presented. The MO is a DBR laser, with a micro heater embedded on top of the DBR grating for wavelength tunability. The emitted light of the MO is collimated and coupled into a tapered amplifier using micro cylindrical lenses, all constructed on a compact 25 mm × 25 mm conduction cooled laser package. The MOPA system emits light with a measured spectral width smaller than 17 pm, limited by the spectrometer, and with a beam propagation factor of M2 1/e2 = 1.3 in the slow axis. The emission is thus nearly diffraction limited with 79% of the total power within the central lobe (4.9 W diffraction limited). The electrically controlled micro-heater provides up to 5.5 nm of wavelength tunability, up to a wavelength of 977.3 nm, while maintaining an output power variation of only +/- 0.16 % for the entire tuning range.

  14. Novel 755-nm diode laser vs. conventional 755-nm scanned alexandrite laser: Side-by-side comparison pilot study for thorax and axillary hair removal.

    Science.gov (United States)

    Paasch, Uwe; Wagner, Justinus A; Paasch, Hartmut W

    2015-01-01

    Alexandrite (755 nm) and diode lasers (800-810 nm) are commonly used for hair removal. The alexandrite laser technology is somewhat cumbersome whereas new diode lasers are more robust. Recently, alexandrite-like 755 nm wavelength diodes became available. To compare the efficacy, tolerability, and subject satisfaction of a 755 nm diode laser operated in conventional (HR) and non-conventional in-motion (SHR) modes with a conventional scanned alexandrite 755 nm laser for chest and axillary hair removal. A prospective, single-center, proof of principle study was designed to evaluate the safety, efficacy and handling of a 755 nm diode laser system in comparison to a standard alexandrite 755 nm scanning hair removal laser. The new 755 nm diode is suitable to be used in SHR and HR mode and has been tested for its safety, efficacy and handling in a volunteer with success. Overall, both systems showed a high efficacy in hair reduction (88.8% 755 nm diode laser vs. 77.7% 755 nm alexandrite laser). Also, during the study period, no severe adverse effects were reported. The new 755 nm diode laser is as effective and safe as the traditional 755 nm alexandrite laser. Additionally, treatment with the 755 nm diode laser with HR and SHR modes was found to be less painful.

  15. Reduced nonlinearities in 100-nm high SOI waveguides

    Science.gov (United States)

    Lacava, C.; Marchetti, R.; Vitali, V.; Cristiani, I.; Giuliani, G.; Fournier, M.; Bernabe, S.; Minzioni, P.

    2016-03-01

    Here we show the results of an experimental analysis dedicated to investigate the impact of optical non linear effects, such as two-photon absorption (TPA), free-carrier absorption (FCA) and free-carrier dispersion (FCD), on the performance of integrated micro-resonator based filters for application in WDM telecommunication systems. The filters were fabricated using SOI (Silicon-on-Insulator) technology by CEA-Leti, in the frame of the FP7 Fabulous Project, which aims to develop low-cost and high-performance integrated optical devices to be used in new generation passive optical- networks (NG-PON2). Different designs were tested, including both ring-based structures and racetrack-based structures, with single-, double- or triple- resonator configuration, and using different waveguide cross-sections (from 500 x 200 nm to 825 x 100 nm). Measurements were carried out using an external cavity tunable laser source operating in the extended telecom bandwidth, using both continuous wave signals and 10 Gbit/s modulated signals. Results show that the use 100-nm high waveguide allows reducing the impact of non-linear losses, with respect to the standard waveguides, thus increasing by more than 3 dB the maximum amount of optical power that can be injected into the devices before causing significant non-linear effects. Measurements with OOK-modulated signals at 10 Gbit/s showed that TPA and FCA don't affect the back-to-back BER of the signal, even when long pseudo-random-bit-sequences (PRBS) are used, as the FCD-induced filter-detuning increases filter losses but "prevents" excessive signal degradation.

  16. Polishing Sapphire Substrates by 355 nm Ultraviolet Laser

    Directory of Open Access Journals (Sweden)

    X. Wei

    2012-01-01

    Full Text Available This paper tries to investigate a novel polishing technology with high efficiency and nice surface quality for sapphire crystal that has high hardness, wear resistance, and chemical stability. A Q-switched 355 nm ultraviolet laser with nanosecond pulses was set up and used to polish sapphire substrate in different conditions in this paper. Surface roughness Ra of polished sapphire was measured with surface profiler, and the surface topography was observed with scanning electronic microscope. The effects of processing parameters as laser energy, pulse repetition rate, scanning speed, incident angle, scanning patterns, and initial surface conditions on surface roughness were analyzed.

  17. High bit rate germanium single photon detectors for 1310nm

    Science.gov (United States)

    Seamons, J. A.; Carroll, M. S.

    2008-04-01

    There is increasing interest in development of high speed, low noise and readily fieldable near infrared (NIR) single photon detectors. InGaAs/InP Avalanche photodiodes (APD) operated in Geiger mode (GM) are a leading choice for NIR due to their preeminence in optical networking. After-pulsing is, however, a primary challenge to operating InGaAs/InP single photon detectors at high frequencies1. After-pulsing is the effect of charge being released from traps that trigger false ("dark") counts. To overcome this problem, hold-off times between detection windows are used to allow the traps to discharge to suppress after-pulsing. The hold-off time represents, however, an upper limit on detection frequency that shows degradation beginning at frequencies of ~100 kHz in InGaAs/InP. Alternatively, germanium (Ge) single photon avalanche photodiodes (SPAD) have been reported to have more than an order of magnitude smaller charge trap densities than InGaAs/InP SPADs2, which allowed them to be successfully operated with passive quenching2 (i.e., no gated hold off times necessary), which is not possible with InGaAs/InP SPADs, indicating a much weaker dark count dependence on hold-off time consistent with fewer charge traps. Despite these encouraging results suggesting a possible higher operating frequency limit for Ge SPADs, little has been reported on Ge SPAD performance at high frequencies presumably because previous work with Ge SPADs has been discouraged by a strong demand to work at 1550 nm. NIR SPADs require cooling, which in the case of Ge SPADs dramatically reduces the quantum efficiency of the Ge at 1550 nm. Recently, however, advantages to working at 1310 nm have been suggested which combined with a need to increase quantum bit rates for quantum key distribution (QKD) motivates examination of Ge detectors performance at very high detection rates where InGaAs/InP does not perform as well. Presented in this paper are measurements of a commercially available Ge APD

  18. Megasonic cleaning strategy for sub-10nm photomasks

    Science.gov (United States)

    Hsu, Jyh-Wei; Samayoa, Martin; Dress, Peter; Dietze, Uwe; Ma, Ai-Jay; Lin, Chia-Shih; Lai, Rick; Chang, Peter; Tuo, Laurent

    2016-10-01

    One of the main challenges in photomask cleaning is balancing particle removal efficiency (PRE) with pattern damage control. To overcome this challenge, a high frequency megasonic cleaning strategy is implemented. Apart from megasonic frequency and power, photomask surface conditioning also influences cleaning performance. With improved wettability, cleanliness is enhanced while pattern damage risk is simultaneously reduced. Therefore, a particle removal process based on higher megasonic frequencies, combined with proper surface pre-treatment, provides improved cleanliness without the unintended side effects of pattern damage, thus supporting the extension of megasonic cleaning technology into 10nm half pitch (hp) device node and beyond.

  19. 5 nm structures produced by direct laser writing

    International Nuclear Information System (INIS)

    Pavel, E; Jinga, S; Andronescu, E; Vasile, B S; Rotiu, E; Ionescu, L; Mazilu, C

    2011-01-01

    Here we present a new approach to overcome the optical diffraction limit by using novel materials. In the paper, we report experimental results obtained by high-resolution transmission electron microscopy (HRTEM) and optical absorption spectroscopy, for a fluorescent photosensitive glass-ceramic containing rare-earth ions such as samarium (Sm). Using a home built dynamic tester, with a low power laser, we recorded nanostructures having 5 nm line widths. In the line structure, measurements reveal the presence of silver nanocrystals with few nanometre sizes. HRTEM shows that there is a random orientation of the nanocrystals. A writing mechanism with three steps is proposed.

  20. Comparison of a novel high-power blue diode laser (λ=442 nm) with Ho:YAG (λ=2100 nm), Tm fiber (λ=1940 nm), and KTP (λ=532 nm) lasers for soft tissue ablation

    Science.gov (United States)

    Vinnichenko, Victoriya; Kovalenko, Anastasiya; Arkhipova, Valeriya; Yaroslavsky, Ilya; Altshuler, Gregory; Gapontsev, Valentin

    2018-02-01

    Three lasers were directly compared, including the Ho:YAG laser (λ = 2100 nm), Tm fiber laser (λ = 1940 nm) operating in 3 different modes (CW, regular pulse, and super pulse), and blue diode laser (λ = 442 nm) for vaporization and coagulation efficiency for treating blood-rich soft tissues, ex vivo, in a porcine kidney model at quasi-contact cutting in water. In addition, experimental results were compared with published data on performance of KTP laser (λ = 532 nm) at similar experimental settings (Power = 60 W and cutting speed = 2 mm/s). Tm fiber laser in pulsed mode and blue laser produced highest vaporization rates of 3.7 and 3.4 mm3/s, respectively. Tm fiber laser (in both CW and pulsed modes) also produced the largest coagulation zone among the laser sources tested. A carbonization zone was observed for Tm fiber laser in CW and pulsed modes, as well as for the blue diode laser. Tm fiber laser in super-pulse mode and Ho:YAG laser both resulted in irregular coagulation zones without carbonization. Comparison with known data for KTP laser revealed that tissue effects of the blue laser are similar to that of the KTP laser. These results suggest that the combination of the two lasers (Tm fiber and blue diode) in one system may achieve high cutting efficiency and optimal coagulation for hemostasis during surgical treatment. Ex vivo testing of the combined system revealed feasibility of this approach. The combination of the CW Tm fiber laser (120W) and the blue diode laser (60W) emitting through a combination tip were compared with CW 120 W Tm fiber laser alone and 120 W Ho:YAG laser. Vaporization rates measured 34, 28, and 6 mm3/s, and coagulation zones measured 0.6, 1.3, and 1.7 mm, respectively. A carbonization zone was only observed with CW Tm fiber laser. The vaporization rate of combined CW Tm fiber laser / blue diode laser was comparable to published data for KTP laser for equivalent total power. Thus, high-power blue diode laser, Tm fiber laser, and

  1. Diode laser spectroscopy of oxygen electronic band at 760 nm

    International Nuclear Information System (INIS)

    Lucchesini, A.; De Rosa, M.; Gozzini, S.

    1998-01-01

    Collisional broadening and shift coefficients have been obtained by analyzing the line shapes of oxygen absorptions in the 760 nm electronic band. By using a diode laser spectrometer with commercially available etherostructure Al x Ga 1-x As diode lasers operating in 'free-running mode', line shape parameters have been collected at room temperature by varying the gas pressure. A systematic study has been carried on seven absorption lines by scanning the diode laser emission wavelength around the gas resonances. The weak absorption lines have been detected by using the wavelength modulation (WM) spectroscopy technique with second-harmonic detection

  2. Printed sub-100 nm polymer-derived ceramic structures.

    Science.gov (United States)

    Duong, Binh; Gangopadhyay, Palash; Brent, Josh; Seraphin, Supapan; Loutfy, Raouf O; Peyghambarian, Nasser; Thomas, Jayan

    2013-05-01

    We proposed an unconventional fabrication technique called spin-on nanoprinting (SNAP) to generate and transfer sub-100 nm preceramic polymer patterns onto flexible and rigid substrates. The dimensions of printed nanostructures are almost the same as those of the mold, since the ceramic precursor used is a liquid. The printed patterns can be used as a replica for printing second-generation structures using other polymeric materials or they can be further converted to desirable ceramic structures, which are very attractive for high-temperature and harsh environment applications. SNAP is an inexpensive parallel process and requires no special equipment for operation.

  3. A 205GHz Amplifier in 90nm CMOS Technology

    Science.gov (United States)

    2017-03-01

    10.5dB power gain, Psat of -1.6dBm, and P1dB ≈ -5.8dBm in a standard 90nm CMOS process. Moreover, the design employs internal (layout-based) /external...other advantages, such as low- cost , reliability, and mixed-mode analog/digital chips, intensifying its usage in the mm-wave band [5]. CMOS has several... disadvantages at the higher frequency range with the worst case scenario happening when the device operates near its fmax. This is chiefly due to

  4. Spectroscopy of Pluto, 380-930 Nm at Six Longitudes

    Science.gov (United States)

    Cruikshank, D. P.; Pinilla-Alonso, N.; Lorenzi, V.; Grundy, William; Licandro, J.; Binzel, R. P.

    2014-01-01

    We have obtained spectra of the Pluto-Charon pair (unresolved) in the wavelength range 380-930 nm with resolution approx..450 at six roughly equally spaced longitudes. The data were taken in May and June, 2014, with the 4.2-m Isaac Newton Telescope at Roque de Los Muchachos Observatory in the Canary Islands, using the ACAM (auxiliary-port camera) in spectrometer mode, and using two solar analog stars. The new spectra clearly show absorption bands of solid CH4 at 620, 728, and 850-910 nm, which were known from earlier work. The 620-nm CH4 band is intrinsically very weak, and its appearance indicates a long optical path-length through the ice. This is especially true if it arises from CH4 dissolved in N2 ice. Earlier work (Owen et al. Science 261, 745, 1993) on the near-infrared spectrum of Pluto (1-2.5 microns) has shown that the CH4 bands are shifted to shorter wavelengths because the CH4 occurs as a solute in beta-phase crystalline N2. The optical path-length through the N2 crystals must be on the order of several cm to produce the N2 band observed at 2.15 microns. The new spectra exhibit a pronounced red slope across the entire wavelength range; the slope is variable with longitude, and differs in a small but significant way from that measured at comparable longitudes by Grundy & Fink (Icarus 124, 329, 1996) in their 15-year study of Pluto's spectrum (500-1000 nm). The new spectra will provide an independent means for calibrating the color filter bands on the Multispectral Visible Imaging Camera (MVIC) (Reuter et al. Space Sci. Rev. 140, 129, 2008) on the New Horizons spacecraft, which will encounter the Pluto-Charon system in mid-2015. They will also form the basis of modeling the spectrum of Pluto at different longitudes to help establish the nature of the non-ice component(s) of Pluto's surface. It is presumed that the non-ice component is the source of the yellow-red coloration of Pluto, which is known to be variable across the surface.

  5. 240 nm UV LEDs for LISA test mass charge control

    Science.gov (United States)

    Olatunde, Taiwo; Shelley, Ryan; Chilton, Andrew; Serra, Paul; Ciani, Giacomo; Mueller, Guido; Conklin, John

    2015-05-01

    Test Masses inside the LISA Gravitational Reference Sensor must maintain almost pure geodesic motion for gravitational waves to be successfully detected. LISA requires residual test mass accelerations below 3 fm/s2/√Hz at all frequencies between 0.1 and 3 mHz. One of the well-known noise sources is associated with the charges on the test masses which couple to stray electrical potentials and external electromagnetic fields. LISA Pathfinder will use Hg-discharge lamps emitting mostly around 254 nm to discharge the test masses via photoemission in its 2015/16 flight. A future LISA mission launched around 2030 will likely replace the lamps with newer UV-LEDs. Presented here is a preliminary study of the effectiveness of charge control using latest generation UV-LEDs which produce light at 240 nm with energy above the work function of pure Au. Their lower mass, better power efficiency and small size make them an ideal replacement for Hg lamps.

  6. 240 nm UV LEDs for LISA test mass charge control

    International Nuclear Information System (INIS)

    Olatunde, Taiwo; Shelley, Ryan; Chilton, Andrew; Serra, Paul; Ciani, Giacomo; Mueller, Guido; Conklin, John

    2015-01-01

    Test Masses inside the LISA Gravitational Reference Sensor must maintain almost pure geodesic motion for gravitational waves to be successfully detected. LISA requires residual test mass accelerations below 3 fm/s 2 /√Hz at all frequencies between 0.1 and 3 mHz. One of the well-known noise sources is associated with the charges on the test masses which couple to stray electrical potentials and external electromagnetic fields. LISA Pathfinder will use Hg-discharge lamps emitting mostly around 254 nm to discharge the test masses via photoemission in its 2015/16 flight. A future LISA mission launched around 2030 will likely replace the lamps with newer UV-LEDs. Presented here is a preliminary study of the effectiveness of charge control using latest generation UV-LEDs which produce light at 240 nm with energy above the work function of pure Au. Their lower mass, better power efficiency and small size make them an ideal replacement for Hg lamps. (paper)

  7. Stress release during cyclic loading of 20 nm palladium films

    International Nuclear Information System (INIS)

    Lukáč, František; Vlček, Marián; Vlach, Martin; Wagner, Stefan; Uchida, Helmut; Pundt, Astrid; Bell, Anthony; Čížek, Jakub

    2015-01-01

    Highlights: • Repeated hydrogenation of 20 nm Pd films was investigated by in situ X-ray diffraction. • Hydride precipitates form coherent interfaces with matrix in nanocrystalline and epitaxial thin films. • Grain boundaries affect precipitation of the hydride phase in the nanocrystalline film. • Stress in epitaxial film is tensile due to different thermal expansion of Pd and sapphire. • After hydrogen absorption/desorption cycle the stress in both films becomes tensile. - Abstract: Gas phase loading of nanocrystalline and epitaxial 20 nm Pd films deposited on single crystalline sapphire substrates was studied in this work. The nanocrystalline film was deposited at room temperature and the epitaxial film deposited at 800 °C. The nanocrystalline film suffers from in-plane compressive stress imposed by atomic peening processes. The epitaxial film exhibits tensile stress caused by the different thermal expansion coefficients of Pd and sapphire substrate. Coherent phase transition into the hydride phase was observed both for the nanocrystalline and for the epitaxial film. For both films, the lattice parameters continuously increase during the phase transition to the hydride phase. Both films exhibit enhanced hydride formation pressure compared to bulk Pd. Misfit dislocations are formed at interface between Pd film and substrate during hydrogenation. This leads to irreversible change of stress state of the films subjected to sorption and desorption cycle with hydrogen

  8. Quality metric for accurate overlay control in <20nm nodes

    Science.gov (United States)

    Klein, Dana; Amit, Eran; Cohen, Guy; Amir, Nuriel; Har-Zvi, Michael; Huang, Chin-Chou Kevin; Karur-Shanmugam, Ramkumar; Pierson, Bill; Kato, Cindy; Kurita, Hiroyuki

    2013-04-01

    The semiconductor industry is moving toward 20nm nodes and below. As the Overlay (OVL) budget is getting tighter at these advanced nodes, the importance in the accuracy in each nanometer of OVL error is critical. When process owners select OVL targets and methods for their process, they must do it wisely; otherwise the reported OVL could be inaccurate, resulting in yield loss. The same problem can occur when the target sampling map is chosen incorrectly, consisting of asymmetric targets that will cause biased correctable terms and a corrupted wafer. Total measurement uncertainty (TMU) is the main parameter that process owners use when choosing an OVL target per layer. Going towards the 20nm nodes and below, TMU will not be enough for accurate OVL control. KLA-Tencor has introduced a quality score named `Qmerit' for its imaging based OVL (IBO) targets, which is obtained on the-fly for each OVL measurement point in X & Y. This Qmerit score will enable the process owners to select compatible targets which provide accurate OVL values for their process and thereby improve their yield. Together with K-T Analyzer's ability to detect the symmetric targets across the wafer and within the field, the Archer tools will continue to provide an independent, reliable measurement of OVL error into the next advanced nodes, enabling fabs to manufacture devices that meet their tight OVL error budgets.

  9. Final report for SNL/NM environmental drilling project

    International Nuclear Information System (INIS)

    Wemple, R.P.; Meyer, R.D.; Staller, G.E.; Layne, R.R.

    1994-11-01

    Concern for the environment and cost reduction are driving forces for a broad effort in government and the private sector to develop new, more cost-effective technologies for characterizing, monitoring and remediating environmental sites. Secondary goals of the characterization, monitoring and remediation (CMR) activity are: minimize secondary waste generation, minimize site impact, protect water tables, and develop methods/strategies to apply new technologies. The Sandia National Laboratories (SNL) project in directional boring for CMR of waste sites with enhanced machinery from the underground utility installation industry was initiated in 1990. The project has tested a variety of prototype machinery and hardware built by the industrial partner, Charles Machine Works (CMW), and SNL at several sites (Savannah River Site (SRS), Hanford, SNL, Kirtland AFB (KAFB), CMW), successfully installed usable horizontal environmental test wells at SRS and SNL/KAFB, and functioned as a clearing house for information regarding application of existing commercial machinery to a variety of governmental and commercial sites. The project has continued to test and develop machinery in FY 94. The original goal of cost-effectiveness is being met through innovation, adaptation, and application of fundamental concepts. Secondary goals are being met via a basic philosophy of open-quotes cut/thrust and compact cuttings without adding large quantities of fluidclose quotes to an environmental problem site. This technology will be very cost-effective where applicable. Technology transfer and commercialization by CMW is ongoing and will continue into FY 95. Technology transfer to the private sector is ongoing and reflected in increasing machinery sales to environmental contractors. Education of regulatory agencies resulting in restructuring of appropriate regulatory standards for specification of the horizontal drilling techniques continues to be a long-range goal

  10. Final report for SNL/NM environmental drilling project

    Energy Technology Data Exchange (ETDEWEB)

    Wemple, R.P.; Meyer, R.D.; Staller, G.E. [Sandia National Labs., Albuquerque, NM (United States); Layne, R.R. [Charles Machine Works, Inc., Perry, OK (United States)

    1994-11-01

    Concern for the environment and cost reduction are driving forces for a broad effort in government and the private sector to develop new, more cost-effective technologies for characterizing, monitoring and remediating environmental sites. Secondary goals of the characterization, monitoring and remediation (CMR) activity are: minimize secondary waste generation, minimize site impact, protect water tables, and develop methods/strategies to apply new technologies. The Sandia National Laboratories (SNL) project in directional boring for CMR of waste sites with enhanced machinery from the underground utility installation industry was initiated in 1990. The project has tested a variety of prototype machinery and hardware built by the industrial partner, Charles Machine Works (CMW), and SNL at several sites (Savannah River Site (SRS), Hanford, SNL, Kirtland AFB (KAFB), CMW), successfully installed usable horizontal environmental test wells at SRS and SNL/KAFB, and functioned as a clearing house for information regarding application of existing commercial machinery to a variety of governmental and commercial sites. The project has continued to test and develop machinery in FY 94. The original goal of cost-effectiveness is being met through innovation, adaptation, and application of fundamental concepts. Secondary goals are being met via a basic philosophy of {open_quotes}cut/thrust and compact cuttings without adding large quantities of fluid{close_quotes} to an environmental problem site. This technology will be very cost-effective where applicable. Technology transfer and commercialization by CMW is ongoing and will continue into FY 95. Technology transfer to the private sector is ongoing and reflected in increasing machinery sales to environmental contractors. Education of regulatory agencies resulting in restructuring of appropriate regulatory standards for specification of the horizontal drilling techniques continues to be a long-range goal.

  11. Scalability of Ferroelectric Tunnel Junctions to Sub-100 nm Dimensions

    Science.gov (United States)

    Abuwasib, Mohammad

    The ferroelectric tunnel junction (FTJ) is an emerging low-power device that has potential application as a non-volatile memory and logic element in beyond-CMOS circuits. As a beyond- CMOS device, it is necessary to investigate the device scaling limit of FTJs to sub-50 nm dimensions. In addition to the fabrication of scaled FTJs, the integration challenges and CMOS compatibility of the device needs to be addressed. FTJ device performance including ON/OFF ratio, memory retention time, switching endurance, write /read speed and power dissipation need to be characterized for benchmarking of this emerging device, compared to its charge-based counterparts such as DRAM, NAND/NOR flash, as well as to other emerging memory devices. In this dissertation, a detailed investigation of scaling of BaTiO3 (BTO) based FTJs was performed, from full-scale integration to electrical characterization. Two types of FTJs with La0.67Sr0.33MnO3 (LSMO) and SrRuO3 (SRO) bottom electrodes were investigated in this work namely; Co/BTO/LSMO and Co/BTO/SRO. A CMOS compatible fabrication process for integration of Co/BTO/LSMO FTJ devices ( 3x3 microm 2) was demonstrated for the first time using standard photolithography and self-aligned RIE technique. The fabricated FTJ device showed switching behavior, however, degradation of the LSMO contact was observed during the fabrication process. A detailed investigation of the contact properties of bottom electrode materials (LSMO, SRO) for BTO-based FTJs was performed. The process and thermal stability of different contact overlayers (Ti, Pt) was explained to understand the nature of the ohmic contacts for metal to SRO and LSMO layers. Noble metals-to-SRO was found to form the most stable contacts for FTJs. Based on this study, a systematic scalability study of Co/BTO/SRO FTJs was carried out from micron ( 3x3 microm2) to submicron ( 200x200 nm2) dimensions. Positive UP Negative Down (PUND) measurement confirms the ferroelectric properties of the BTO

  12. Safety and Efficacy of a 1550nm/1927nm Dual Wavelength Laser for the Treatment of Photodamaged Skin.

    Science.gov (United States)

    Narurkar, Vic A; Alster, Tina S; Bernstein, Eric F; Lin, Tina J; Loncaric, Anya

    2018-01-01

    BACKGROUND: Fractional photothermolysis (FP) is a popular treatment option for photodamaged skin and addresses shortcomings of ablative skin resurfacing and nonablative dermal remodeling. Previous studies have demonstrated that FP using the 1550nm wavelength has led to improvement of ultrastructural changes and clinical effects associated with photodamaged skin in the deeper dermal structures, while treatment with the 1927nm wavelength has shown clinical effects in the superficial dermis. Both wavelengths produce precise microscopic treatment zones (MTZs) in the skin. The two wavelengths used in combination may optimize the delivery of fractional nonablative resurfacing intended for dermal and epidermal coagulation of photodamage skin. OBJECTIVES: To evaluate the safety and efficacy of a 1550/1927 Laser System (Fraxel Dual, Solta), using both 1550nm and 1927nm wavelengths in combination for treatment of facial and non-facial photodamage. METHODS: Prospective, multi-center, post-market study in subjects with clinically identifiable photodamage (N=35) (Fitzpatrick skin types I-IV). Both 1550nm and 1927nm wavelengths were used at each treatment visit. Investigator assessment of the affected area(s) occurred at one week, one month and 3 months after a series of up to four treatments. Severity of adverse events (AEs) were assessed using a 4-point scale (where 0=none and 3=marked). Assessments included erythema, edema, hyperkeratosis, hyper- and hypo-pigmentation, scarring, itchiness, dryness, and flaking. Severity of photoaging, fine and coarse wrinkling, mottled hyperpigmentation, sallowness, and tactile roughness at baseline was assessed using the same scale. Investigators and subjects assessed overall appearance of photodamage and pigmentation based on a 5-point quartile improvement scale at all follow-up visits (where 0=no improvement and 4=very significant improvement [76%-100%]). RESULTS: There was a positive treatment effect at all study visits, with moderate

  13. Laser Treatment of Professional Tattoos With a 1064/532-nm Dual-Wavelength Picosecond Laser.

    Science.gov (United States)

    Kauvar, Arielle N B; Keaney, Terrence C; Alster, Tina

    2017-12-01

    Picosecond-domain laser pulses improve the photomechanical disruption of tattoos. This study evaluates the efficacy and safety of a novel, dual-wavelength, 1,064/532-nm, picosecond-domain laser for tattoo clearance. This was a prospective, self-controlled, clinical study of 34 subjects with 39 tattoos treated at 2 sites with an interval of 4.8 ± 1.6 weeks and up to 10 treatments (mean, 7.5). Blinded evaluation and investigator assessment of serial digital images was performed to evaluate treatment efficacy in the 36 tattoos that received at least 3 treatments. Investigators also assessed efficacy before each treatment visit up to 10 treatments. Safety and tolerability was evaluated for all 39 tattoos that underwent at least 1 treatment. Blinded evaluation demonstrated that lightening of tattoos was achieved in all subjects, with 86% (31 of 36 tattoos) showing at least a 50% clearance after 3 treatments. Adverse events were few and transient in nature. Patient satisfaction and treatment tolerability were high. Treatment of single-colored and multicolored tattoos with this novel 1,064/532-nm picosecond laser is highly safe and effective.

  14. Interim report for SNL/NM environmental drilling project

    Energy Technology Data Exchange (ETDEWEB)

    Wemple, R.P.; Meyer, R.D. [Sandia National Labs., Albuquerque, NM (United States); Layne, R.R. [Charles Machine Works, Inc., Perry, OK (United States)

    1994-02-01

    Concern for the environment and cost reduction are the driving forces for a broad effort in government and the private sector to develop new, more cost-effective technologies for characterizing, monitoring and remediating environmental sites. Secondary goals of the characterization, monitoring and remediation (CMR) activity are: minimize secondary waste generation, minimize site impact, protect water tables, and develop methods/strategies to apply new technologies. The Sandia National Laboratories (SNL) project in directional boring for CMR of waste sites with enhanced machinery from the underground utility installation industry was initiated in 1990. Preliminary activities included surveying the directional drilling access needs of various DOE sites, identifying an existing class of machinery that could be enhanced for environmental work through development, and establishing a mutually beneficial working relationship with an industry partner. Since that time the project has tested a variety of prototype machinery and hardware built by the industrial partner, and SNL. The project continues to test and develop the machinery and technique refinements needed for future applications at DOE, DOD, and private sector sites. The original goal of cost-effectiveness is being met through innovation, adaptation, and application of fundamental concepts. Secondary goals are being met via a basic philosophy of ``cut/thrust and compact cuttings without adding large quantities of fluid`` to an environmental problem site. Technology transfer to the private sector is ongoing and ultimately should result in commercial availability of the machinery. Education of regulatory agencies resulting in restructuring appropriate regulatory standards for specification of the horizontal drilling techniques will be a final project goal.

  15. Site Restoration

    Energy Technology Data Exchange (ETDEWEB)

    Noynaert, L.; Bruggeman, A.; Cornelissen, R.; Massaut, V.; Rahier, A

    2002-04-01

    The objectives, the programme, and the achievements of SCK-CEN's Site Restoration Department for 2001 are described. Main activities include the decommissioning of the BR3 PWR-reactor as well as other clean-up activities, projects on waste minimisation and the management of spent fuel and the flow of dismantled materials and the recycling of materials from decommissioning activities based on the smelting of metallic materials in specialised foundries. The department provides consultancy and services to external organisations and performs R and D on new techniques including processes for the treatment of various waste components including the reprocessing of spent fuel, the treatment of tritium, the treatment of liquid alkali metals into cabonates through oxidation, the treatment of radioactive organic waste and the reconditioning of bituminised waste products.

  16. Mochovce site

    International Nuclear Information System (INIS)

    1997-01-01

    In Mochovce site the construction of four units of WWER 440 NPP with V-213 type of reactor is being carried out. The financing of Mochovce units completion was resolved in April 1996. The completion work commenced at the construction site under leadership of SKODA Prague, the general supplier. The completion work on building part and tests of constructional electric distributions and lightning constructors started. The revisions in technological part were finished, and final protocols from revisions are the basis for starting of completion work. The assembly of transport container anchorage,ventilation system in hermetic areas and hermetic coverage of pools for stored spent nuclear fuel is being carried out. The pre-completion tests of instrumentation and control of ventilation systems, individual dosimetric control in medical station, and tests of nuclear programme according to commissioning and assembling work schedule at the equipment for physical protection of the NPP area started. Inspection activities at Mochovce were performed in accordance with inspection plan for 1996. Evaluation of routine inspections was performed by means of quarterly protocols. Main findings from the inspections performed in Mochovce were in the following areas: (a) deficiencies in the knowledge of the respective regulation and conditions from the Resolution of the state regulatory body, concerning selected employees; (b) training of the selected employees; (c) aim of the measures imposes by inspectors is to eliminate deficiencies in preparation of programmes for pre-completion and completion testing. NRA SR assessment activities at Mochovce NPP were focused mainly on approving and inspecting of design modification to approving programmes for pre-completion and completion testing of system s and equipment and on approving quality assurance programmes. The suggestions of international missions, which reviewed Mochovce safety in the years, were taken into consideration in the programme

  17. Deposition and characterization of ITO films produced by laser ablation at 355 nm

    DEFF Research Database (Denmark)

    Holmelund, E.; Thestrup Nielsen, Birgitte; Schou, Jørgen

    2002-01-01

    Indium tin oxide (ITO) films have been deposited by pulsed laser deposition (PLD) at 355 nm. Even though the absorption of laser light at the wavelength 355 nm is much smaller than that of the standard excimer lasers for PLD at 248 nm and 193 nm, high-quality films can be produced. At high fluence...

  18. NM-Scale Anatomy of an Entire Stardust Carrot Track

    Science.gov (United States)

    Nakamura-Messenger, K.; Keller, L. P.; Clemett, S. J.; Messenger, S.

    2009-01-01

    Comet Wild-2 samples collected by NASA s Stardust mission are extremely complex, heterogeneous, and have experienced wide ranges of alteration during the capture process. There are two major types of track morphologies: "carrot" and "bulbous," that reflect different structural/compositional properties of the impactors. Carrot type tracks are typically produced by compact or single mineral grains which survive essentially intact as a single large terminal particle. Bulbous tracks are likely produced by fine-grained or organic-rich impactors [1]. Owing to their challenging nature and especially high value of Stardust samples, we have invested considerable effort in developing both sample preparation and analytical techniques tailored for Stardust sample analyses. Our report focuses on our systematic disassembly and coordinated analysis of Stardust carrot track #112 from the mm to nm-scale.

  19. Pollution Prevention Opportunity Assessment for the SNL/NM cafeterias.

    Energy Technology Data Exchange (ETDEWEB)

    McCord, Samuel Adam

    2005-12-01

    This Pollution Prevention Opportunity Assessment (PPOA) was conducted for the two Sandia National Laboratories/New Mexico cafeteria facilities between May and August 2005. The primary purpose of this PPOA is to assess waste and resource reduction opportunities and issue Pollution Prevention (P2) recommendations for Sandia's food service facilities. This PPOA contains recommendations for energy, water and resource reduction, as well as material substitution based upon environmentally preferable purchasing. Division 3000 has requested the PPOA report as part of the Division's compliance effort to implement the Environmental Management System (EMS) per DOE Order 450.1. This report contains a summary of the information collected and analyses performed with recommended options for implementation. The SNL/NM P2 Group will work with Division 3000 and the respective cafeteria facilities to implement these options.

  20. Extreme ultraviolet resist materials for sub-7 nm patterning

    KAUST Repository

    Li, Li; Liu, Xuan; Pal, Shyam; Wang, Shulan; Ober, Christopher K.; Giannelis, Emmanuel P.

    2017-01-01

    Continuous ongoing development of dense integrated circuits requires significant advancements in nanoscale patterning technology. As a key process in semiconductor high volume manufacturing (HVM), high resolution lithography is crucial in keeping with Moore's law. Currently, lithography technology for the sub-7 nm node and beyond has been actively investigated approaching atomic level patterning. EUV technology is now considered to be a potential alternative to HVM for replacing in some cases ArF immersion technology combined with multi-patterning. Development of innovative resist materials will be required to improve advanced fabrication strategies. In this article, advancements in novel resist materials are reviewed to identify design criteria for establishment of a next generation resist platform. Development strategies and the challenges in next generation resist materials are summarized and discussed.

  1. EST Table: NM_001111334 [KAIKOcDNA[Archive

    Lifescience Database Archive (English)

    Full Text Available NM_001111334 Br-c 10/09/29 81 %/420 aa ref|NP_001104804.1| broad-complex isoform Z1... [Bombyx mori] dbj|BAD23978.1| broad-complex Z1-isoform [Bombyx mori] dbj|BAD23983.1| broad-complex Z1-isofo...rm [Bombyx mori] dbj|BAD24045.1| Broad-Complex isoform Z1 [Bombyx mori] dbj|BAD24046.1| Broad-Complex isofor...m Z1 [Bombyx mori] dbj|BAD46732.1| broad-complex A-Z1 isoform [Bombyx mori] dbj|BAD46739.1| broad...-complex B-Z1 isoform [Bombyx mori] dbj|BAF43564.1| Broad-Complex isoform Z1 [Bombyx mori] 1

  2. Database of average-power damage thresholds at 1064 nm

    International Nuclear Information System (INIS)

    Rainer, F.; Hildum, E.A.; Milam, D.

    1987-01-01

    We have completed a database of average-power, laser-induced, damage thresholds at 1064 nm on a variety of materials. Measurements were made with a newly constructed laser to provide design input for moderate and high average-power laser projects. The measurements were conducted with 16-ns pulses at pulse-repetition frequencies ranging from 6 to 120 Hz. Samples were typically irradiated for time ranging from a fraction of a second up to 5 minutes (36,000 shots). We tested seven categories of samples which included antireflective coatings, high reflectors, polarizers, single and multiple layers of the same material, bare and overcoated metal surfaces, bare polished surfaces, and bulk materials. The measured damage threshold ranged from 2 for some metals to > 46 J/cm 2 for a bare polished glass substrate. 4 refs., 7 figs., 1 tab

  3. Photooxidation of polystyrene: irradiation at 254 and 365 nm

    International Nuclear Information System (INIS)

    Otocka, E.P.; Curran, S.; Porter, R.S.

    1983-01-01

    Studies have been made of the near surface photooxidation of atactic polystyrene films prepared in the absence of air. The samples were photooxidized on exposure to air at two frequencies, 254 and 365 nm, using a calibrated mercury irradiation source with filters. Most studies were made at 40 0 C and as a function of irradiation time with the reactions characterized by changes in molecular weight and composition. The former was evaluated by gel permeation chromatography and the latter by transmission Fourier transform infrared ir spectroscopy and by multiple-internal-reflectance ir spectra using different angles and different crystals to evaluate compositions as a function of film depth. Species identified in photooxidation include the generation of hydroperoxides and the appearance of carbonyl bands with the latter identified by the spectral shift associated with the exposure of the photooxidized polystyrene surface to ammonia. These results suggest that principal products of near-surface oxidation of polystyrene are carboxylic acids. 6 figures, 1 table

  4. Pixel front-end development in 65 nm CMOS technology

    International Nuclear Information System (INIS)

    Havránek, M; Hemperek, T; Kishishita, T; Krüger, H; Wermes, N

    2014-01-01

    Luminosity upgrade of the LHC (HL-LHC) imposes severe constraints on the detector tracking systems in terms of radiation hardness and capability to cope with higher hit rates. One possible way of keeping track with increasing luminosity is the usage of more advanced technologies. Ultra deep sub-micron CMOS technologies allow a design of complex and high speed electronics with high integration density. In addition, these technologies are inherently radiation hard. We present a prototype of analog pixel front-end integrated circuit designed in 65 nm CMOS technology with applications oriented towards the ATLAS Pixel Detector upgrade. The aspects of ultra deep sub-micron design and performance of the analog pixel front-end circuits will be discussed

  5. Extreme ultraviolet resist materials for sub-7 nm patterning.

    Science.gov (United States)

    Li, Li; Liu, Xuan; Pal, Shyam; Wang, Shulan; Ober, Christopher K; Giannelis, Emmanuel P

    2017-08-14

    Continuous ongoing development of dense integrated circuits requires significant advancements in nanoscale patterning technology. As a key process in semiconductor high volume manufacturing (HVM), high resolution lithography is crucial in keeping with Moore's law. Currently, lithography technology for the sub-7 nm node and beyond has been actively investigated approaching atomic level patterning. EUV technology is now considered to be a potential alternative to HVM for replacing in some cases ArF immersion technology combined with multi-patterning. Development of innovative resist materials will be required to improve advanced fabrication strategies. In this article, advancements in novel resist materials are reviewed to identify design criteria for establishment of a next generation resist platform. Development strategies and the challenges in next generation resist materials are summarized and discussed.

  6. Wide modulation bandwidth terahertz detection in 130 nm CMOS technology

    Science.gov (United States)

    Nahar, Shamsun; Shafee, Marwah; Blin, Stéphane; Pénarier, Annick; Nouvel, Philippe; Coquillat, Dominique; Safwa, Amr M. E.; Knap, Wojciech; Hella, Mona M.

    2016-11-01

    Design, manufacturing and measurements results for silicon plasma wave transistors based wireless communication wideband receivers operating at 300 GHz carrier frequency are presented. We show the possibility of Si-CMOS based integrated circuits, in which by: (i) specific physics based plasma wave transistor design allowing impedance matching to the antenna and the amplifier, (ii) engineering the shape of the patch antenna through a stacked resonator approach and (iii) applying bandwidth enhancement strategies to the design of integrated broadband amplifier, we achieve an integrated circuit of the 300 GHz carrier frequency receiver for wireless wideband operation up to/over 10 GHz. This is, to the best of our knowledge, the first demonstration of low cost 130 nm Si-CMOS technology, plasma wave transistors based fast/wideband integrated receiver operating at 300 GHz atmospheric window. These results pave the way towards future large scale (cost effective) silicon technology based terahertz wireless communication receivers.

  7. Extreme ultraviolet resist materials for sub-7 nm patterning

    KAUST Repository

    Li, Li

    2017-06-26

    Continuous ongoing development of dense integrated circuits requires significant advancements in nanoscale patterning technology. As a key process in semiconductor high volume manufacturing (HVM), high resolution lithography is crucial in keeping with Moore\\'s law. Currently, lithography technology for the sub-7 nm node and beyond has been actively investigated approaching atomic level patterning. EUV technology is now considered to be a potential alternative to HVM for replacing in some cases ArF immersion technology combined with multi-patterning. Development of innovative resist materials will be required to improve advanced fabrication strategies. In this article, advancements in novel resist materials are reviewed to identify design criteria for establishment of a next generation resist platform. Development strategies and the challenges in next generation resist materials are summarized and discussed.

  8. TMV Disk Scaffolds for Making sub-30 nm Silver Nanorings.

    Science.gov (United States)

    Bayram, Serene; Zahr, Omar; Del Re, Julia; Blum, Amy Szuchmacher

    2018-01-01

    Nanosized bioscaffolds can be utilized to tackle the challenge of size reduction of metallic rings owing to their miniature features as well as their well-known biomineralization capacity. The tobacco mosaic virus coat protein is used as a command surface to grow and assemble silver nanoparticles into sub-30 nm rings. The versatility of TMV allows the formation of both solid silver rings and rings consisting of discrete silver nanoparticles. The pH-dependent coulombic surface map along with the annular geometry of the protein aggregate allow the generation of rings with or without a central nanoparticle. Our silver rings are believed to be the smallest to date, and they can offer a test material for existing theories on metallic nanorings of this heretofore unreached size scale.

  9. Sub-10 nm patterning with DNA nanostructures: a short perspective

    Science.gov (United States)

    Du, Ke; Park, Myeongkee; Ding, Junjun; Hu, Huan; Zhang, Zheng

    2017-11-01

    DNA is the hereditary material that contains our unique genetic code. Since the first demonstration of two-dimensional (2D) nanopatterns by using designed DNA origami ˜10 years ago, DNA has evolved into a novel technique for 2D and 3D nanopatterning. It is now being used as a template for the creation of sub-10 nm structures via either ‘top-down’ or ‘bottom-up’ approaches for various applications spanning from nanoelectronics, plasmonic sensing, and nanophotonics. This perspective starts with an histroric overview and discusses the current state-of-the-art in DNA nanolithography. Emphasis is put on the challenges and prospects of DNA nanolithography as the next generation nanomanufacturing technique.

  10. Technology of focus detection for 193nm projection lithographic tool

    Science.gov (United States)

    Di, Chengliang; Yan, Wei; Hu, Song; Xu, Feng; Li, Jinglong

    2012-10-01

    With the shortening printing wavelength and increasing numerical aperture of lithographic tool, the depth of focus(DOF) sees a rapidly drop down trend, reach a scale of several hundred nanometers while the repeatable accuracy of focusing and leveling must be one-tenth of DOF, approximately several dozen nanometers. For this feature, this article first introduces several focusing technology, Obtained the advantages and disadvantages of various methods by comparing. Then get the accuracy of dual-grating focusing method through theoretical calculation. And the dual-grating focusing method based on photoelastic modulation is divided into coarse focusing and precise focusing method to analyze, establishing image processing model of coarse focusing and photoelastic modulation model of accurate focusing. Finally, focusing algorithm is simulated with MATLAB. In conclusion dual-grating focusing method shows high precision, high efficiency and non-contact measurement of the focal plane, meeting the demands of focusing in 193nm projection lithography.

  11. Spectral narrowing of a 980 nm tapered diode laser bar

    DEFF Research Database (Denmark)

    Vijayakumar, Deepak; Jensen, Ole Bjarlin; Lucas Leclin, Gaëlle

    2011-01-01

    High power diode laser bars are interesting in many applications such as solid state laser pumping, material processing, laser trapping, laser cooling and second harmonic generation. Often, the free running laser bars emit a broad spectrum of the order of several nanometres which limit their scope...... been "smile corrected" using individual phase masks for each emitter. The external cavity consists of the laser bar, both fast and slow axis micro collimators, smile correcting phase mask, 6.5x beam expanding lens combination, a 1200 lines/mm reflecting grating with 85% efficiency in the first order......, a slow axis focusing cylindrical lens of 40 mm focal length and an output coupler which is 10% reflective. In the free running mode, the laser emission spectrum was 5.5 nm wide at an operating current of 30A. The output power was measured to be in excess of 12W. Under the external cavity operation...

  12. Lasing at 300 nm and below: Optical challenges and perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Garzella, D. [Universite de Paris-Sud, Orsay (France); Couprie, M.E. [Universite de Paris-Sud, Orsay (France)]|[CEA DSM DRECAM SPAM, Gif Sur Yvette (France); Billardon, M. [ESPCI, Paris (France)

    1995-12-31

    The FEL experiment in the visible and near UV on the Super ACO storage ring has given, since 1989, important informations on the SRFEL dynamics and, furthermore, a very good beam stability has been achieved. In addition, the operation at 350 nm with this good stability and a long beam lifetime allowed us to perform the first user experiment in biology and to start with a campaign for using the laser as photons source for experiments in other domains, coupling FEL light and the Synchrotron Radiation. For this, FEL starts to be very competitive with respect to the other conventional laser sources, provided that it could oscillate further in the UV, say at 300 nm and below. So, the real challenge is now given by the lasing at shorter wavelengths and, for this, by the optical technology existing nowadays. Since 1992 the efforts have been concentrating to look for every kind of solution allowing us to overcome the problem of having a very low gain. From an optical point of view, in the range of wavelengths explored, there is a lack of transparents dielectric materials for substrates and coatings. Substrates are required at the same time to be relatively not absorbing (a few tens 10{sup -6}), to have a very good surface quality (RMS roughness below 10 {Angstrom}) because of scattering losses dramatically increasing in this spectral range and, due to the thermal load of the undulator emission, to have adequate thermal characteristics. In order to fulfill all these requirements, a good characterisation and modelisation of the substrates is needed, especially to correlate thermal loading and mechanical deformations from one hand, and roughness and scattering losses from the other hand. Coatings must be not absorbing too and, above all, the most amorphous as possible (this could be obtained with IBS deposition technique), in order to insure a good reproduction of the substrate roughness at the interfaces and on the top layer and an higher resistance to the XUV photons load.

  13. Time-resolved photodissociation of oxygen at 162 nm

    International Nuclear Information System (INIS)

    Trushin, Sergei A; Schmid, Wolfram E; Fuss, Werner

    2011-01-01

    Oxygen was excited by 10 fs pulses in the Schumann-Runge continuum at 162 nm, which is by 0.57 eV above the dissociation limit. It was probed by high-intensity ionization at 810 nm with 10 14 W cm -2 , measuring the ion yields. The O 2 + signal decays in 4.3 fs, which is much shorter than the expected time for dissociation. It is ascribed to a rapid decay of the ionization probability. In a similar time, the ion in the second excited state (with excess energy taken over from the neutral) reaches the dissociation limit, whereas this time would be much longer from the two lower ion states. In fact, the O + signal rises to a (first) maximum at 6 fs. The preference for the higher ion state is rationalized by an intermediate resonance in the neutral molecule for which the polarization dependence also provides evidence. But the shape of the O + signal is very odd: it exhibits three maxima (at 6, 29 and 53 fs) of increasing intensity, before decaying rapidly (≤3.5 fs) to a pedestal. In contrast to the first maximum, the others appear at times when there is practically no interatomic force left in the excited state. We postulate a highly repulsive doubly excited state as a resonance for interpreting the second maximum, and for the third an ion-pair state lying further outside. Comparison is made with enhanced ionization, which has often been found at large interatomic distances on multiple ionization in strong laser fields. Consistent with this mechanism is the absence of similar observations at negative delay times, where five fundamental photons act as a pump and the fifth harmonic as a probe.

  14. (-)PPAP: a new and selective ligand for sigma binding sites.

    Science.gov (United States)

    Glennon, R A; Battaglia, G; Smith, J D

    1990-11-01

    Most agents employed for the investigation of sigma (sigma) binding sites display relatively low affinity for these sites, bind both at sigma sites and at either phencyclidine (PCP) sites or dopamine receptors with similar affinity, and/or produce some dopaminergic activity in vivo. We describe a new agent, (-)PPAP or R(-)-N-(3-phenyl-n-propyl)-1-phenyl-2-aminopropane hydrochloride, that binds with high affinity and selectivity at sigma (IC50 = 24 nM) versus either PCP sites (IC50 greater than 75,000 nM) or D1 and D2 dopamine receptors (IC50 greater than 5,000 nM). The sigma affinity of this agent is comparable to that of the standard ligands (+)-3-PPP and DTG. Furthermore, although (-)PPAP is structurally related to amphetamine, it neither produces nor antagonizes amphetamine-like stimulus effect in rats trained to discriminate 1 mg/kg of S(+)amphetamine from saline.

  15. Temporal-spatial structure of magnetic merging at the magnetopause inferred from 557.7-nm all-sky images

    Directory of Open Access Journals (Sweden)

    N. C. Maynard

    2004-09-01

    Full Text Available We demonstrate that high-resolution 557.7-nm all-sky images are useful tools for investigating the spatial and temporal evolution of merging on the dayside magnetopause. Analysis of ground and satellite measurements leads us to conclude that high-latitude merging events can occur at multiple sites simultaneously and vary asynchronously on time scales of 30s to 3min. Variations of 557.7nm emissions were observed at a 10s cadence at Ny-Ålesund on 19 December 2001, while significant changes in the IMF clock angle were reaching the magnetopause. The optical patterns are consistent with a scenario in which merging occurs around the rim of the high-latitude cusp at positions dictated by the IMF clock angle. Electrons energized at merging sites represent plausible sources for 557.7nm emissions in the cusp. Polar observations at the magnetopause have directly linked enhanced fluxes of ≥0.5keV electrons with merging. Spectra of electrons responsible for some of the emissions, measured during a DMSP F15 overflight, exhibit "inverted-V" features, indicating further acceleration above the ionosphere. SuperDARN spectral width boundaries, characteristic of open-closed field line transitions, are located at the equatorward edge of the 557.7nm emissions. Optical data suggest that with IMF BY>0, the Northern Hemisphere cusp divides into three source regions. When the IMF clock angle was ~150° structured 557.7-nm emissions came from east of the 13:00 MLT meridian. At larger clock angles the emissions appeared between 12:00 and 13:00 MLT. No significant 557.7-nm emissions were detected in the prenoon MLT sector. MHD simulations corroborate our scenario, showing that with the observed large dipole-tilt and IMF clock angles, merging sites develop near the front and eastern portions of the high-altitude cusp rim in the Northern Hemisphere and near the western part of the cusp rim in the Southern Hemisphere.

  16. Quasi-three level Nd:YLF fundamental and Raman laser operating under 872-nm and 880-nm direct diode pumping

    Science.gov (United States)

    Wetter, Niklaus U.; Bereczki, Allan; Paes, João. Pedro Fonseca

    2018-02-01

    Nd:YLiF4 is the gain material of choice whenever outstanding beam quality or a birefringent gain material is necessary such as in certain applications for terahertz radiation or dual-frequency mode-locking. However, for high power CW applications the material is hampered by a low thermal fracture threshold. This problem can be mitigated by special 2D pump set-ups or by keeping the quantum defect to a minimum. Direct pumping into the upper laser level of Nd:YLiF4 is usually performed at 880 nm. For quasi-three level laser emission at 908 nm, direct pumping at this wavelength provides a high quantum defect of 0.97, which allows for very high CW pump powers. Although the direct pumping transition to the upper laser state at 872 nm has a slightly smaller quantum defect of 0.96, its pump absorption cross section along the c-axis is 50% higher than at 880 nm, leading to a higher absorption efficiency. In this work we explore, for the first time to our knowledge, 908 nm lasing under 872 nm diode pumping and compare the results with 880 nm pumping for quasicw and cw operation. By inserting a KGW crystal in the cavity, Raman lines at 990 nm and 972 nm were obtained for the first time from a directly pumped 908 nm Nd:YLF fundamental laser for both quasi-cw and cw conditions.

  17. Laser-damage thresholds of thin-film optical coatings at 248 nm

    International Nuclear Information System (INIS)

    Milam, D.; Rainer, F.; Lowdermilk, W.H.

    1981-01-01

    We have measured the laser-induced damage thresholds for 248 nm wavelength light of over 100 optical coatings from commercial vendors and research institutions. All samples were irradiated once per damage site with temporally multi-lobed, 20-ns pulses generated by a KrF laser. The survey included high, partial, and dichroic reflectors, anti-reflective coatings, and single layer films. The samples were supplied by ten vendors. The majority of samples tested were high reflectors and antireflective coatings. The highest damage thresholds were 8.5 to 9.4 J/cm 2 , respectively. Although these represent extremes of what has been tested so far, several vendors have produced coatings of both types with thresholds which consistently exceed 6 J/cm 2 . Repeated irradiations of some sites were made on a few samples. These yielded no degradation in threshold, but in fact some improvement in damage resistance. These same samples also exhibited no change in threshold after being retested seven months later

  18. Comparison of the ablation ability of nucleus pulposus after 1,064 nm Nd:YAG laser and 980 nm diode laser radiation.

    Science.gov (United States)

    Yin, Jian; Han, Zhengfeng; Guo, Baofeng; Guo, Han; Zhang, Tongtong; Zeng, Yanjun; Ren, Longxi

    2015-07-01

    To compare the ablation ability of nucleus pulposus after 1,064 nm Nd:YAG laser and 980 nm diode laser radiation. Goat spine specimen (GSS) was radiated using Nd:YAG laser and 980 nm diode laser and then divided into five groups based on the final energy--200, 400, 600, 800 and 1,000 J groups. The ablation quality of nucleus pulposus after radiation was recorded. The ablation quality of GSS was greater at higher radiation energies in both lasers. When compared at the same energy level, the ablation quality of GSS was greater in 980 nm diode laser than in 1,064 nm Nd:YAG laser. Statistical significance was observed in 200 and 400 J groups (P diode laser showed better ablation ability than 1,064 nm Nd:YAG laser.

  19. Nantenna for Standard 1550 nm Optical Communication Systems

    Directory of Open Access Journals (Sweden)

    Waleed Tariq Sethi

    2016-01-01

    Full Text Available Nanoscale transmission and reception technologies will play a vital role and be part of the next generation communication networks. This applies for all application fields including imaging, health, biosensing, civilian, and military communications. The detection of light frequency using nanooptical antennas may possibly become a good competitor to the semiconductor based photodetector because of the simplicity of integration, cost, and inherent capability to detect the phase and amplitude instead of power only. In this paper, authors propose simulated design of a hexagonal dielectric loaded nantenna (HDLN and explore its potential benefits at the standard optical C-band (1550 nm. The proposed nantenna consists of “Ag-SiO2-Ag” structure, consisting of “Si” hexagonal dielectric with equal lengths fed by “Ag” nanostrip transmission line. The simulated nantenna achieves an impedance bandwidth of 3.7% (190.9 THz–198.1 THz and a directivity of 8.6 dBi, at a center frequency of 193.5 THz, covering most of the ITU-T standard optical transmission window (C-band. The hexagonal dielectric nantenna produces HE20δ modes and the wave propagation is found to be end-fire. The efficiency of the nantenna is proven via numerical expressions, thus making the proposed design viable for nanonetwork communications.

  20. Laser ablation of nanoscale particles with 193 nm light

    International Nuclear Information System (INIS)

    Choi, J H; Lucas, D; Koshland, C P

    2007-01-01

    Laser interaction with nanoscale particles is distinct and different from laser-bulk material interaction, where a hot plasma is normally created. Here, we review our studies on 193 nm laser ablation of various nanoscale particles including NaCl, soot, polystyrene, and gold. The 20 ns laser beam with fluences up to 0.3 J/cm 2 irradiates nanoparticles in a gas stream at laser repetition rates from 10 to 100 Hz. The particle size distributions before and after irradiation are measured with a scanning mobility particle sizer (SMPS), and particle morphology is examined with electron microscopy. All the nanomaterials studied exhibit a similar disintegration pattern and similar particle formation characteristics. No broadband emission associated with particle heating or optical breakdown is observed. The nanoparticles formed after irradiation have a smaller mean diameter and an order of magnitude higher number concentration with a more spherical shape compared to the original particles. We use the photon-atom ratio (PAR) to interpret the laser-particle interaction energetics

  1. Electrical control of antiferromagnetic metal up to 15 nm

    Science.gov (United States)

    Zhang, PengXiang; Yin, GuFan; Wang, YuYan; Cui, Bin; Pan, Feng; Song, Cheng

    2016-08-01

    Manipulation of antiferromagnetic (AFM) spins by electrical means is on great demand to develop the AFM spintronics with low power consumption. Here we report a reversible electrical control of antiferromagnetic moments of FeMn up to 15 nm, using an ionic liquid to exert a substantial electric-field effect. The manipulation is demonstrated by the modulation of exchange spring in [Co/Pt]/FeMn system, where AFM moments in FeMn pin the magnetization rotation of Co/Pt. By carrier injection or extraction, the magnetic anisotropy of the top layer in FeMn is modulated to influence the whole exchange spring and then passes its influence to the [Co/Pt]/FeMn interface, through a distance up to the length of exchange spring that fully screens electric field. Comparing FeMn to IrMn, despite the opposite dependence of exchange bias on gate voltages, the same correlation between carrier density and exchange spring stiffness is demonstrated. Besides the fundamental significance of modulating the spin structures in metallic AFM via all-electrical fashion, the present finding would advance the development of low-power-consumption AFM spintronics.

  2. Synchrotron Radiation Lithography for Manufacturing Integrated Circuits Beyond 100 nm.

    Science.gov (United States)

    Kinoshita, H; Watanabe, T; Niibe, M

    1998-05-01

    Extreme ultraviolet lithography is a powerful tool for printing features of 0.1 micro m and below; in Japan and the USA there is a growing tendency to view it as the wave of the future. With Schwarzschild optics, replication of a 0.05 micro m pattern has been demonstrated in a 25 micro m square area. With a two-aspherical-mirror system, a 0.15 micro m pattern has been replicated in a ring slit area of 20 mm x 0.4 mm; a combination of this system with illumination optics and synchronized mask and wafer stages has enabled the replication of a 0.15 micro m pattern in an area of 10 mm x 12.5 mm. Furthermore, in the USA, the Sandia National Laboratory has succeeded in fabricating a fully operational NMOS transistor with a gate length of 0.1 micro m. The most challenging problem is the fabrication of mirrors with the required figure error of 0.28 nm. However, owing to advances in measurement technology, mirrors can now be made to a precision that almost satisfies this requirement. Therefore, it is time to move into a rapid development phase in order to obtain a system ready for practical use by the year 2004. In this paper the status of individual technologies is discussed in light of this situation, and future requirements for developing a practical system are considered.

  3. High-speed stimulated Brillouin scattering spectroscopy at 780 nm

    Directory of Open Access Journals (Sweden)

    Itay Remer

    2016-09-01

    Full Text Available We demonstrate a high-speed stimulated Brillouin scattering (SBS spectroscopy system that is able to acquire stimulated Brillouin gain point-spectra in water samples and Intralipid tissue phantoms over 2 GHz within 10 ms and 100 ms, respectively, showing a 10-100 fold increase in acquisition rates over current frequency-domain SBS spectrometers. This improvement was accomplished by integrating an ultra-narrowband hot rubidium-85 vapor notch filter in a simplified frequency-domain SBS spectrometer comprising nearly counter-propagating continuous-wave pump-probe light at 780 nm and conventional single-modulation lock-in detection. The optical notch filter significantly suppressed stray pump light, enabling detection of stimulated Brillouin gain spectra with substantially improved acquisition times at adequate signal-to-noise ratios (∼25 dB in water samples and ∼15 dB in tissue phantoms. These results represent an important step towards the use of SBS spectroscopy for high-speed measurements of Brillouin gain resonances in scattering and non-scattering samples.

  4. Observations of thunderstorm-related 630 nm airglow depletions

    Science.gov (United States)

    Kendall, E. A.; Bhatt, A.

    2015-12-01

    The Midlatitude All-sky imaging Network for Geophysical Observations (MANGO) is an NSF-funded network of 630 nm all-sky imagers in the continental United States. MANGO will be used to observe the generation, propagation, and dissipation of medium and large-scale wave activity in the subauroral, mid and low-latitude thermosphere. This network is actively being deployed and will ultimately consist of nine all-sky imagers. These imagers form a network providing continuous coverage over the western United States, including California, Oregon, Washington, Utah, Arizona and Texas extending south into Mexico. This network sees high levels of both medium and large scale wave activity. Apart from the widely reported northeast to southwest propagating wave fronts resulting from the so called Perkins mechanism, this network observes wave fronts propagating to the west, north and northeast. At least three of these anomalous events have been associated with thunderstorm activity. Imager data has been correlated with both GPS data and data from the AIRS (Atmospheric Infrared Sounder) instrument on board NASA's Earth Observing System Aqua satellite. We will present a comprehensive analysis of these events and discuss the potential thunderstorm source mechanism.

  5. Diode-pumped continuous-wave eye-safe Nd:YAG laser at 1415 nm.

    Science.gov (United States)

    Lee, Hee Chul; Byeon, Sung Ug; Lukashev, Alexei

    2012-04-01

    We describe the output performance of the 1415 nm emission in Nd:YAG in a plane-concave cavity under traditional pumping into the 4F5/2 level (808 nm) and direct in-band pumping into the 4F3/2 level (885 nm). An end-pumped Nd:YAG laser yielded maximum cw output power of 6.3 W and 4.2 W at 885 nm and 808 nm laser diode (LD) pumping, respectively. To the best of our knowledge, this is the highest output power of a LD-pumped 1415 nm laser.

  6. Broadband light generation at ~1300 nm through spectrally recoiled solitons and dispersive waves

    DEFF Research Database (Denmark)

    Falk, Peter Andreas; Frosz, Michael Henoch; Bang, Ole

    2008-01-01

    We experimentally study the generation of broadband light at ~1300 nm from an 810 nm Ti:sapphire femtosecond pump laser. We use two photonic crystal fibers with a second infrared zero-dispersion wavelength (λZ2) and compare the efficiency of two schemes: in one fiber λZ2=1400 nm and the light...... at 1300 nm is composed of spectrally recoiled solitons; in the other fiber λZ2=1200 nm and the light at 1300 nm is composed of dispersive waves....

  7. Two transistor cluster DICE Cells with the minimum area for a hardened 28-nm CMOS and 65-nm SRAM layout design

    International Nuclear Information System (INIS)

    Stenin, V.Ya.; Stepanov, P.V.

    2015-01-01

    A hardened DICE cell layout design is based on the two spaced transistor clusters of the DICE cell each consisting of four transistors. The larger the distance between these two CMOS transistor clusters, the more robust the hardened DICE SRAM to Single Event Upsets. Some versions of the 28-nm and 65-nm DICE CMOS SRAM block composition have been suggested with minimum cluster distances of 2.27-2.32 mkm. The area of hardened 28-nm DICE CMOS cells is larger than the area of 28-nm 6T CMOS cells by a factor of 2.1 [ru

  8. Identification of remediation needs and technology development focus areas for the Environmental Restoration (ER) Project at Sandia National Laboratories/New Mexico (SNL/NM)

    International Nuclear Information System (INIS)

    Tucker, M.D.

    1995-06-01

    The Environmental Restoration (ER) Project has been tasked with the characterization, assessment, remediation and long-term monitoring of contaminated waste sites at Sandia National Laboratories/New Mexico (SNL/NM). Many of these sites will require remediation which will involve the use of baseline technologies, innovative technologies that are currently under development, and new methods which will be developed in the near future. The Technology Applications Program (TAP) supports the ER Project and is responsible for development of new technologies for use at the contaminated waste sites, including technologies that will be used for remediation and restoration of these sites. The purpose of this report is to define the remediation needs of the ER Project and to identify those remediation needs for which the baseline technologies and the current development efforts are inadequate. The area between the remediation needs and the existing baseline/innovative technology base represents a technology gap which must be filled in order to remediate contaminated waste sites at SNL/NM economically and efficiently. In the first part of this report, the remediation needs of the ER Project are defined by both the ER Project task leaders and by TAP personnel. The next section outlines the baseline technologies, including EPA defined Best Demonstrated Available Technologies (BDATs), that are applicable at SNL/NM ER sites. This is followed by recommendations of innovative technologies that are currently being developed that may also be applicable at SNL/NM ER sites. Finally, the gap between the existing baseline/innovative technology base and the remediation needs is identified. This technology gap will help define the future direction of technology development for the ER Project

  9. Novel EUV photoresist for sub-7nm node (Conference Presentation)

    Science.gov (United States)

    Furukawa, Tsuyoshi; Naruoka, Takehiko; Nakagawa, Hisashi; Miyata, Hiromu; Shiratani, Motohiro; Hori, Masafumi; Dei, Satoshi; Ayothi, Ramakrishnan; Hishiro, Yoshi; Nagai, Tomoki

    2017-04-01

    Extreme ultraviolet (EUV) lithography has been recognized as a promising candidate for the manufacturing of semiconductor devices as LS and CH pattern for 7nm node and beyond. EUV lithography is ready for high volume manufacturing stage. For the high volume manufacturing of semiconductor devices, significant improvement of sensitivity and line edge roughness (LWR) and Local CD Uniformity (LCDU) is required for EUV resist. It is well-known that the key challenge for EUV resist is the simultaneous requirement of ultrahigh resolution (R), low line edge roughness (L) and high sensitivity (S). Especially high sensitivity and good roughness is important for EUV lithography high volume manufacturing. We are trying to improve sensitivity and LWR/LCDU from many directions. From material side, we found that both sensitivity and LWR/LCDU are simultaneously improved by controlling acid diffusion length and efficiency of acid generation using novel resin and PAG. And optimizing EUV integration is one of the good solution to improve sensitivity and LWR/LCDU. We are challenging to develop new multi-layer materials to improve sensitivity and LWR/LCDU. Our new multi-layer materials are designed for best performance in EUV lithography system. From process side, we found that sensitivity was substantially improved maintaining LWR applying novel type of chemical amplified resist (CAR) and process. EUV lithography evaluation results obtained for new CAR EUV interference lithography. And also metal containing resist is one possibility to break through sensitivity and LWR trade off. In this paper, we will report the recent progress of sensitivity and LWR/LCDU improvement of JSR novel EUV resist and process.

  10. Simulation of 50-nm Gate Graphene Nanoribbon Transistors

    Directory of Open Access Journals (Sweden)

    Cedric Nanmeni Bondja

    2016-01-01

    Full Text Available An approach to simulate the steady-state and small-signal behavior of GNR MOSFETs (graphene nanoribbon metal-semiconductor-oxide field-effect transistor is presented. GNR material parameters and a method to account for the density of states of one-dimensional systems like GNRs are implemented in a commercial device simulator. This modified tool is used to calculate the current-voltage characteristics as well the cutoff frequency fT and the maximum frequency of oscillation fmax of GNR MOSFETs. Exemplarily, we consider 50-nm gate GNR MOSFETs with N = 7 armchair GNR channels and examine two transistor configurations. The first configuration is a simplified MOSFET structure with a single GNR channel as usually studied by other groups. Furthermore, and for the first time in the literature, we study in detail a transistor structure with multiple parallel GNR channels and interribbon gates. It is shown that the calculated fT of GNR MOSFETs is significantly lower than that of GFETs (FET with gapless large-area graphene channel with comparable gate length due to the mobility degradation in GNRs. On the other hand, GNR MOSFETs show much higher fmax compared to experimental GFETs due the semiconducting nature of the GNR channels and the resulting better saturation of the drain current. Finally, it is shown that the gate control in FETs with multiple parallel GNR channels is improved while the cutoff frequency is degraded compared to single-channel GNR MOSFETs due to parasitic capacitances of the interribbon gates.

  11. 75 FR 65526 - Xilinx, Inc., Including On-Site Leased Workers of TEKsystems, Albuquerque, NM; Notice of Revised...

    Science.gov (United States)

    2010-10-25

    ..., for integrated circuit test engineers and test equipment engineers for a Product and Test Engineering... engineering services. In the request for reconsideration, workers alleged that the subject firm has shifted abroad the supply of services like and directly competitive with the internal-use engineering services...

  12. 76 FR 2148 - Xilinx, Inc. Including On-Site Leased Workers of TEKsystems, Albuquerque, NM; Notice of Revised...

    Science.gov (United States)

    2011-01-12

    ..., for integrated circuit test engineers and test equipment engineers for a Product and Test Engineering... engineering services. In the request for reconsideration, workers alleged that the subject firm has shifted abroad the supply of services like and directly competitive with the internal-use engineering services...

  13. Design and Fabrication of 850 and 980 nm Vertical Cavity Surface Emitting Laser

    National Research Council Canada - National Science Library

    Das, N

    2004-01-01

    .... VCSELs on GaAs substrates were grown by the molecular beam epitaxy technique. In this report we present detailed procedures to design and fabricate 850-nm top-emitting and 980-nm bottom-emitting VCSELs...

  14. Site-selective spectroscopy of Er in GaN

    International Nuclear Information System (INIS)

    Dierolf, V.; Sandmann, C.; Zavada, J.; Chow, P.; Hertog, B.

    2004-01-01

    We investigated different Er 3+ defect sites found in Er-doped GaN layers by site-selective combined excitation-emission spectroscopy and studied the role of these sites in different direct and multistep excitation schemes. The layers were grown by molecular beam epitaxy and were 200 nm thick. Two majority sites were found along with several minority sites. The sites strongly differ in excitation and energy transfer efficiencies as well as branching ratios during relaxation. For this reason, relative emission intensities from these sites depend strongly on emission and excitation. The sites were identified for several transitions and a comprehensive list of energy levels has been compiled. One of the minority sites appears strongly under ultraviolet excitation above the GaN band gap suggesting that this site is an excellent trap for excitation energy of electron-hole pairs

  15. Investigation of a Pulsed 1550 nm Fiber Laser System (Briefing Charts)

    Science.gov (United States)

    2016-02-14

    Pump dump and splice Pump dump and splice MFA 976 nm 15 W TFB TFB Pump dump and splice Waveform shaping Delay Power meter...filter 976 nm 7.6 W TFB WDM Pump dump and splice Pump dump and splice MFA 976 nm 15 W TFB TFB Pump dump and splice Waveform shaping...Multimode fiber to OSA or photodiode EOM EOM ASE filter ASE filter 976 nm 7.6 W TFB

  16. Combination of Q-switched and quasi long-pulsed 1064-nm Nd:YAG laser, non-ablative 1450-nm diode laser, and ablative 10 600-nm carbon dioxide fractional laser for enlarged pores.

    Science.gov (United States)

    Cho, Sung Bin; Noh, Seongmin; Lee, Sang Ju; Kang, Jin Moon; Kim, Young Koo; Lee, Ju Hee

    2010-07-01

    Currently, there is no gold standard for the treatment of enlarged facial pores. In this report, we describe a patient with enlarged nasal pores which were treated with a combination of a non-ablative 1450-nm diode laser, a Q-switched and quasi long-pulsed 1064-nm Nd:YAG laser, and an ablative 10 600-nm carbon dioxide fractional laser system. Four months after the final treatment, the condition of the patient's pores had markedly improved, and the patient was satisfied with the results.

  17. A comparative study with a 755 nm picosecond Alexandrite laser with a diffractive lens array and a 532 nm/1064 nm Nd:YAG with a holographic optic.

    Science.gov (United States)

    Tanghetti Md, Emil; Jennings, John

    2018-01-01

    This study was performed to better understand the cutaneous effects of using a fractional picosecond laser at 755 nm with a diffractive lens array and a picosecond Nd:YAG laser at 532 mn and 1064 nm with a holographic optic. We characterized the injuries created by these devices on skin clinically and histologically over 24 hours. With this information we modeled the effects of these devices on a cutaneous target. Eight patients, representing Fitzpatrick skin types I-VI, were treated on their backs with a picosecond Alexandrite laser with a diffractive lens array, as well as a picosecond Nd:YAG laser at 532 nm and 1064 nm with a holographic optic. Photographs were taken 15 minutes and 24 hours after treatments. Punch biopsies were obtained at 24 hours and examined histologically. Treatment with the picosecond Nd:YAG laser at both 532 nm and 1064 nm with the holographic optic revealed erythema and small scatted areas of petechial hemorrhage areas immediately and in many cases at 24 hours after treatment. The 755 nm picosecond Alexandrite laser with diffractive lens array produced erythema immediately after treatment, which largely dissipated 24 hours later. Histologies revealed intra-epidermal vacuoles with all three wavelengths. Fractional picosecond Nd:YAG laser at 532 nm and 1064 nm with the holographic optic showed focal areas of dermal and intra-epidermal hemorrhage with areas of vascular damage in some patients. This study demonstrates that both fractional picosecond devices produce vacuoles in the skin, which are most likely due to areas of laser induced optical breakdown (LIOB). In the patients (skin type II-IV) we observed scatter areas of hemorrhage in the skin, due to vascular damage with the 532 nm and 1064 nm, but not with 755 nm wavelengths. Lasers Surg. Med. 50:37-44, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  18. Contaminated Sites in Iowa

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Sites contaminated by hazardous materials or wastes. These sites are those administered by the Contaminated Sites Section of Iowa DNR. Many are sites which are...

  19. Treatment of inflammatory facial acne vulgaris with combination 595-nm pulsed-dye laser with dynamic-cooling-device and 1,450-nm diode laser.

    Science.gov (United States)

    Glaich, Adrienne S; Friedman, Paul M; Jih, Ming H; Goldberg, Leonard H

    2006-03-01

    The 585-nm pulsed-dye laser and the 1,450-nm diode laser have been found effective for the treatment of mild-to-moderate inflammatory facial acne. This study was designed to evaluate the efficacy and safety of the combined treatment with the 595-nm pulsed-dye laser and the 1,450-nm diode laser for inflammatory facial acne. Fifteen patients with inflammatory facial acne were treated with a combination of the 595-nm pulsed-dye laser and the 1,450-nm diode laser. Patients' subjective response to treatment was evaluated regarding improvement in acne, acne scarring, oiliness, and redness of the skin. All patients had reductions in acne lesion counts. Mean lesion counts decreased 52% (P < 0.01), 63% (P < 0.01), and 84% (P < 0.01) after one, two, and three treatments, respectively. Patients described moderate-to-marked improvement in acne, acne scarring, and post-inflammatory erythema. Adverse effects were limited to mild, transient erythema. The combination of the 595-nm pulsed-dye laser and the 1,450-nm diode laser is safe and effective for the treatment of inflammatory facial acne, acne scarring, and post-inflammatory erythema. 2005 Wiley-Liss, Inc.

  20. Impact electrochemistry on screen-printed electrodes for the detection of monodispersed silver nanoparticles of sizes 10-107 nm.

    Science.gov (United States)

    Nasir, Muhammad Zafir Mohamad; Pumera, Martin

    2016-10-12

    Impact electrochemistry provides a useful alternative technique for the detection of silver nanoparticles in solutions. The combined use of impact electrochemistry on screen-printed electrodes (SPEs) for the successful detection of silver nanoparticles provides an avenue for future on-site, point-of-care detection devices to be made for environmental, medicinal and biological uses. Here we discuss the use of screen-printed electrodes for the detection of well-defined monodispersed silver nanoparticles of sizes 10, 20, 40, 80, and 107 nm.

  1. Increase of the photosensitivity of undoped poly(methylmethacrylate) under UV radiation at 325 nm

    DEFF Research Database (Denmark)

    Sáez-Rodríguez, D.; Nielsen, Kristian; Bang, Ole

    2014-01-01

    in undoped PMMA mPOFs with a hexagonal structure of three rings in the inner cladding. Two sets of FBGs were inscribed at two different resonant wavelengths (827 nm and 1562 nm) at different strains using an UV He-Cd laser at 325 nm focused by a lens and scanned over the fibre. We observed an increase...

  2. 16.7 W 885 nm diode-side-pumped actively Q -switched Nd:YAG/YVO4 intracavity Raman laser at 1176 nm

    International Nuclear Information System (INIS)

    Jiang, Pengbo; Zhang, Guizhong; Liu, Jian; Ding, Xin; Sheng, Quan; Sun, Bing; Shi, Rui; Wu, Liang; Yao, Jianquan; Yu, Xuanyi; Wang, Rui

    2017-01-01

    We proposed and experimentally demonstrated the generation of high-power 1176 nm Stokes wave by frequency shifting of a 885 nm diode-side-pumped Nd:YAG laser using a YVO 4 crystal in a Z -shaped cavity configuration. Employing the 885 nm diode-side-pumped scheme and the Z -shaped cavity, for the first time to our knowledge, we realized the thermal management effectively, achieving excellent 1176 nm Stokes wave consequently. With an incident pump power of ∼190.0 W, a maximum average output power of 16.7 W was obtained at the pulse repetition frequency of 10 kHz. The pulse duration and spectrum linewidth of the Stokes wave at the maximum output power were 20.3 ns and ∼0.08 nm, respectively. (paper)

  3. Enhancement of 800 nm upconversion emission in a thulium doped tellurite microstructured fiber pumped by a 1560 nm femtosecond fiber laser

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Zhixu; Zheng, Kezhi [State Key Laboratory of Optical Fiber and Cable Manufacture Technology, Yangtze Optical Fiber and Cable Joint Stock Limited Company, Wuhan 430073 (China); State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun 130012 (China); Yao, Chuanfei; Wang, Shunbin; Qin, Guanshi, E-mail: qings@jlu.edu.cn; Qin, Weiping, E-mail: wpqin@jlu.edu.cn [State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun 130012 (China); Xiong, Liangming; Luo, Jie; Lv, Dajuan [State Key Laboratory of Optical Fiber and Cable Manufacture Technology, Yangtze Optical Fiber and Cable Joint Stock Limited Company, Wuhan 430073 (China); Ohishi, Yasutake [Research Center for Advanced Photon Technology, Toyota Technological Institute, 2-12-1 Hisakata, Tempaku, Nagoya 468–8511 (Japan)

    2016-04-28

    We report enhanced upconversion (UC) fluorescence in Tm{sup 3+} doped tellurite microstructured fibers (TDTMFs) fabricated by using a rod-in-tube method. Under the pumping of a 1560 nm femtosecond fiber laser, ultrabroadband supercontinuum light expanding from ∼1050 to ∼2700 nm was generated in a 4 cm long TDTMF. Simultaneously, intense 800 nm UC emission from the {sup 3}H{sub 4} → {sup 3}H{sub 6} transition of Tm{sup 3+} was observed in the same TDTMF. Compared to that pumped by a 1560 nm continuous wave fiber laser, the UC emission intensity was enhanced by ∼4.1 times. The enhancement was due to the spectral broadening in the TDTMF under the pumping of the 1560 nm femtosecond fiber laser.

  4. Archaeological reconnaissance of a proposed site for the Waste Isolation Plant (WIPP)

    International Nuclear Information System (INIS)

    Nielsen, J.

    1976-01-01

    An archaeological reconnaissance was carried out on Sections 20, 21, 28, and 29 of T 22 S, R 31 E, Eddy County, NM, the core area of a site proposed for disposal of radioactive waste in bedded salt (the Waste Isolation Pilot Plant). This site is located in the Los Medanos area east of Carlsbad, NM. Results of the survey are presented in sections on survey techniques, geology, terrain, floristics, cultural resources, theoretical considerations, site description, and recommendations

  5. Macular autofluorescence in eyes with cystoid macula edema, detected with 488 nm-excitation but not with 580 nm-excitation.

    Science.gov (United States)

    Bessho, Kenichiro; Gomi, Fumi; Harino, Seiyo; Sawa, Miki; Sayanagi, Kaori; Tsujikawa, Motokazu; Tano, Yasuo

    2009-06-01

    Fundus autofluorescence (AF) derives from lipofuscin in the retinal pigment epithelium (RPE). Because lipofuscin is a by-product of phagocytosis of photoreceptors by RPE, AF imaging is expected to describe some functional aspect of the retina. In this study we report distribution of AF in patients showing macular edema. Three eyes with diabetic macular edema (DME) and 11 with retinal vein occlusion (RVO), associated with macular edema (ME) were examined. ME was determined by standard fundus examination, fluorescein angiography (FA) and optical coherence tomography (OCT). AF was recorded using a Heidelberg confocal scanning laser ophthalmoscope (cSLO) with 488 nm laser exciter (488 nm-AF), and a conventional Topcon fundus camera with halogen lamp exciter and 580 nm band-pass filter (580 nm-AF). Color fundus picture, FA image and these two AF images were analyzed by superimposing all images. All subjects presented cystoid macular edema (CME) with petaloid pattern hyperfluorescence in FA. In 488 nm-AF, all eyes (100%) showed macular autofluorescence of a similar shape to that of the CME in FA. In contrast, in 580 nm-AF only one eye (7%) presented this corresponding petaloid-shaped autofluorescence. In all cases, peripheral retinal edemas did not show autofluorescence corresponding to the leakage in FA. In eyes with CME, analogous hyperautofluorescence to the CME was always observed in 488 nm-AF, while it was rarely observed in 580 nm-AF. Moreover, this CME hyperautofluorescence was only seen in the macular area. We hypothesize that autofluorescence from CME may be considered as a "pseudo" or "relative" autofluorescence, due to macular stretching following CME that may result in lateral displacement of macular pigments (MPs) and subsequent reduction of MPs density, as MPs block 488 nm-AF more intensely than 580 nm-AF. Although this phenomenon may not directly indicate change of RPE function, it may be used as a method to assess or track CME non-invasively.

  6. The Type 3 copper site is intact but labile in Type 2-depleted laccase

    DEFF Research Database (Denmark)

    Frank, P; Farver, O; Pecht, I

    1983-01-01

    We report results of experiments designed to characterize the Type 1 and Type 3 copper sites in Rhus laccase depleted of Type 2 copper (T2D). Use of the Lowry method for determining protein concentration yielded the value 5620 +/- 570 M-1 cm-1 for the extinction of the 615-nm absorption band...... as intensity perturbations at 280 and 615 nm. Comparison of difference spectra show that this 330-nm band derives from a Type 3 copper-bound peroxide and not from a reoxidized Type 3 site. Dioxygen reoxidation of ascorbate-reduced T2D laccase produced new difference bands at 330 nm (delta epsilon = 770 M-1 cm...

  7. Texture investigation in the trench depth direction of very fine copper wires less than 100 nm wide using electron backscatter diffraction

    International Nuclear Information System (INIS)

    Khoo, Khyoupin; Onuki, Jin

    2010-01-01

    We clarified the correlations between resistivity and microstructures in the depth direction of copper (Cu) wires. The resistivity of Cu wires increased with the polishing depth ΔH, and the influence of ΔH on resistivity increment was significant for 60 nm wide Cu wires. We attributed this to the fact that the deeper the depth and the finer the line width, the smaller are the grain sizes and the lower are the fractions of {111} textures and Σ3 coincident site lattice boundaries. Among the above factors, the grain size was the dominant factor determining the resistivity of less than 100 nm wide Cu wire.

  8. 20 W continuous-wave cladding-pumped Nd-doped fiber laser at 910 nm.

    Science.gov (United States)

    Laroche, M; Cadier, B; Gilles, H; Girard, S; Lablonde, L; Robin, T

    2013-08-15

    We demonstrate a double-clad fiber laser operating at 910 nm with a record power of 20 W. Laser emission on the three-level scheme is enabled by the combination of a small inner cladding-to-core diameter ratio and a high brightness pump source at 808 nm. A laser conversion efficiency as high as 44% was achieved in CW operating regime by using resonant fiber Bragg reflectors at 910 nm that prevent the lasing at the 1060 nm competing wavelength. Furthermore, in a master oscillator power-amplifier scheme, an amplified power of 14.8 W was achieved at 914 nm in the same fiber.

  9. Laser Application in Dentistry: Irradiation Effects of Nd:YAG 1064 nm and Diode 810 nm and 980 nm in Infected Root Canals—A Literature Overview

    Science.gov (United States)

    Kuypers, Thorsten; Gutknecht, Norbert

    2016-01-01

    Objective. In endodontics, Nd:YAG laser (1064 nm) and diode laser (810 nm and 980 nm) devices are used to remove bacteria in infected teeth. A literature review was elaborated to compare and evaluate the advantages and disadvantages of using these lasers. Methods. Using combined search terms, eligible articles were retrieved from PubMed and printed journals. The initial search yielded 40 titles and 27 articles were assigned to full-text analysis. The studies were classified based upon laser source, laser energy level, duration/similarity of application, and initial and final bacterial count at a minimum of 20 prepared root canals. Part of the analysis was only reduced microorganisms and mechanically treated root canals upon preparation size of ISO 30. All studies were compared to evaluate the most favorable laser device for best results in endodontic therapy. Results. A total of 22 eligible studies were found regarding Nd:YAG laser 1064 nm. Four studies fulfilled all demanded criteria. Seven studies referring to the diode laser 980 nm were examined, although only one fulfilled all criteria. Eleven studies were found regarding the diode laser 810 nm, although only one study fulfilled all necessary criteria. Conclusions. Laser therapy is effective in endodontics, although a comparison of efficiency between the laser devices is not possible at present due to different study designs, materials, and equipment. PMID:27462611

  10. Laser Application in Dentistry: Irradiation Effects of Nd:YAG 1064 nm and Diode 810 nm and 980 nm in Infected Root Canals-A Literature Overview.

    Science.gov (United States)

    Saydjari, Yves; Kuypers, Thorsten; Gutknecht, Norbert

    2016-01-01

    Objective. In endodontics, Nd:YAG laser (1064 nm) and diode laser (810 nm and 980 nm) devices are used to remove bacteria in infected teeth. A literature review was elaborated to compare and evaluate the advantages and disadvantages of using these lasers. Methods. Using combined search terms, eligible articles were retrieved from PubMed and printed journals. The initial search yielded 40 titles and 27 articles were assigned to full-text analysis. The studies were classified based upon laser source, laser energy level, duration/similarity of application, and initial and final bacterial count at a minimum of 20 prepared root canals. Part of the analysis was only reduced microorganisms and mechanically treated root canals upon preparation size of ISO 30. All studies were compared to evaluate the most favorable laser device for best results in endodontic therapy. Results. A total of 22 eligible studies were found regarding Nd:YAG laser 1064 nm. Four studies fulfilled all demanded criteria. Seven studies referring to the diode laser 980 nm were examined, although only one fulfilled all criteria. Eleven studies were found regarding the diode laser 810 nm, although only one study fulfilled all necessary criteria. Conclusions. Laser therapy is effective in endodontics, although a comparison of efficiency between the laser devices is not possible at present due to different study designs, materials, and equipment.

  11. Multiple double cross-section transmission electron microscope sample preparation of specific sub-10 nm diameter Si nanowire devices.

    Science.gov (United States)

    Gignac, Lynne M; Mittal, Surbhi; Bangsaruntip, Sarunya; Cohen, Guy M; Sleight, Jeffrey W

    2011-12-01

    The ability to prepare multiple cross-section transmission electron microscope (XTEM) samples from one XTEM sample of specific sub-10 nm features was demonstrated. Sub-10 nm diameter Si nanowire (NW) devices were initially cross-sectioned using a dual-beam focused ion beam system in a direction running parallel to the device channel. From this XTEM sample, both low- and high-resolution transmission electron microscope (TEM) images were obtained from six separate, specific site Si NW devices. The XTEM sample was then re-sectioned in four separate locations in a direction perpendicular to the device channel: 90° from the original XTEM sample direction. Three of the four XTEM samples were successfully sectioned in the gate region of the device. From these three samples, low- and high-resolution TEM images of the Si NW were taken and measurements of the NW diameters were obtained. This technique demonstrated the ability to obtain high-resolution TEM images in directions 90° from one another of multiple, specific sub-10 nm features that were spaced 1.1 μm apart.

  12. Generation of continuous-wave 194 nm laser for mercury ion optical frequency standard

    Science.gov (United States)

    Zou, Hongxin; Wu, Yue; Chen, Guozhu; Shen, Yong; Liu, Qu; Precision measurement; atomic clock Team

    2015-05-01

    194 nm continuous-wave (CW) laser is an essential part in mercury ion optical frequency standard. The continuous-wave tunable radiation sources in the deep ultraviolet (DUV) region of the spectrum is also serviceable in high-resolution spectroscopy with many atomic and molecular lines. We introduce a scheme to generate continuous-wave 194 nm radiation with SFM in a Beta Barium Borate (BBO) crystal here. The two source beams are at 718 nm and 266 nm, respectively. Due to the property of BBO, critical phase matching (CPM) is implemented. One bow-tie cavity is used to resonantly enhance the 718 nm beam while the 266 nm makes a single pass, which makes the configuration easy to implement. Considering the walk-off effect in CPM, the cavity mode is designed to be elliptical so that the conversion efficiency can be promoted. Since the 266 nm radiation is generated by a 532 nm laser through SHG in a BBO crystal with a large walk-off angle, the output mode is quite non-Gaussian. To improve mode matching, we shaped the 266 nm beam into Gaussian modes with a cylindrical lens and iris diaphragm. As a result, 2.05 mW 194 nm radiation can be generated. As we know, this is the highest power for 194 nm CW laser using SFM in BBO with just single resonance. The work is supported by the National Natural Science Foundation of China (Grant No. 91436103 and No. 11204374).

  13. On the origins of 718 nm fluorescence from Porphyridium cruentum at 77 K.

    Science.gov (United States)

    Wang, R T; Graham, J R; Myers, J

    1980-09-05

    Emission spectra and transient behavior of fluorescence in Porphyridium cruentum have been studied in search of the pathway of excitation energy from the phycobilisome to Photosystem I (PS I) of photosynthesis. For activating light at 436 nm, absorbed almost entirely by chlorophyll, fluorescence is dominated by the 718 nm band generally attributed to chlorophyll of PS I. Activating light at 550 nm, absorbed mostly by the phycobilisome, gives rise to the distinctive fluorescence band of PS II chlorophyll at 696 nm but also gives a large component at 718 nm. Analysis depends critically upon the source of emission at 718 nm under 550 nm activation: does it arise from PS I or PS IIC0 Ley and Butler (Ley, A.C. and Butler, W.L. (1976) Proc. Natl. Acad. Sci. U.S.A. 73, 3956-3960) have proposed that the 718 nm arises mostly from PS I, to which it is transferred by spillover from PS II. We suggest a different proposition: that under 550 nm activation most of the 718 emission arises from PS II. Analysis shows that this proposition provides an alternative explanation. Using the small change in fluorescence yield observed under 436 nm activation as a monitor of excitation in PS I, we provide evidence that under 550 activation most of the 718 nm fluorescence arises from PS II.

  14. Surgical performance of a 405-nm diode laser in treatment of soft tissue

    International Nuclear Information System (INIS)

    Kato, J; Akashi, G; Moriya, K; Hirai, Y; Hatayama, H; Inoue, A; Miyazaki, H

    2008-01-01

    The study was conducted to evaluate the surgical performance of a 405-nm diode laser ex vivo. The experiments were carried out using tuna tissue, which was irradiated with a 405-nm diode laser at output powers of 400 mW (694 W/cm 2 ) to 1 W (1735 W/cm 2 ) on a motorized stage moving at a rate of 1 mm/sec. As a control, a 920-nm diode laser was used with the same irradiation conditions. After irradiation, the thickness of ablation and coagulation was measured by stereoscopic microscopy and evaluated statistically. Ablation and coagulation zones were obtained with 405-nm laser irradiation, but not with irradiation at 920 nm. Ablation depth increased significantly with output power and a thick coagulation zone was observed with 405-nm irradiation. The 405-nm diode laser performed well for incising and coagulating soft tissue at a low power density

  15. In vivo retinal optical coherence tomography at 1030 nm with enhanced penetration into the choroid

    Science.gov (United States)

    Unterhuber, A.; Povazay, B.; Hermann, B.; Sattmann, H.; Michels, S.; Sacu, S.; Ahlers, C.; Scholda, C.; Chavez-Pirson, A.; Schmidt-Erfurth, U.; Fercher, Adolf F.; Drexler, W.

    2005-08-01

    In vivo retinal imaging with ~ 8 μm axial resolution at 1030 nm is demonstrated for the first time, enabling enhanced penetration into the choroid. A new high power, broad bandwidth light source based on amplified spontaneous emission (NP Photonics, λc = 1030 nm, Δλ= 50 nm, Pout = 25 mW) has been interfaced to a time domain ophthalmic OCT system. In vivo retinal OCT tomograms performed at 800 nm are compared to those achieved at 1030 nm. Retinal OCT at longer wavelengths, e.g. 1030 nm significantly improves the visualization of the retinal pigment epithelium/choriocapillaris/choroid interface and might therefore provide new insight into choroidal/choriocapillary changes in age-related macular degeneration and other diseases of the retinal pigment epithelium (RPE)-choroid complex. 1030 nm OCT could also become a valuable tool in monitoring treatment effects on the choroids as in Verteporfin therapy.

  16. Combined 595-nm and 1,064-nm laser irradiation of recalcitrant and hypertrophic port-wine stains in children and adults.

    Science.gov (United States)

    Alster, Tina S; Tanzi, Elizabeth L

    2009-06-01

    Although pulsed dye laser (PDL) treatment of port-wine stain (PWS) has long been proven safe and effective, incomplete clearance of these vascular malformations can be problematic. In addition, advanced PWS with deeper coloration and tissue hypertrophy can be particularly difficult to treat because of the superficial dermal penetration of 585- to 595-nm light. The purpose of this study was to evaluate the safety and efficacy of a novel device that delivers sequential pulses of 595- and 1,064-nm wavelengths in the treatment of recalcitrant and hypertrophic PWS. Twenty-five children and adults (skin phototypes I-III) with recalcitrant or hypertrophic PWS showing incomplete clearance after 10 prior PDL treatments were included in the study. Successive treatments using a 595-nm PDL and a 1,064-nm neodymium-doped yttrium-aluminum-garnet (Nd:YAG) laser were delivered at 6- to 8-week intervals. Two masked assessors determined clinical improvement of treatment areas using independent evaluation of comparative photographs at baseline and 3 months after treatment using a standard quartile grading scale. The use of dual 595-/1,064-nm wavelengths provided continued improvement of PWS that were previously recalcitrant to ongoing PDL therapy. Side effects were limited to transient erythema, edema, and mild purpura. Rare vesicle formation was observed, with no subsequent scarring or undesirable pigmentary changes. The novel dual 595-nm PDL and 1,064-nm Nd:YAG laser is an effective treatment for PWS that are recalcitrant to PDL therapy alone.

  17. Short-term clinical outcomes of laser supported periodontal treatment concept using Er,Cr:YSGG (2780nm) and diode (940 nm): a pilot study

    Science.gov (United States)

    Odor, Alin A.; Violant, Deborah; Badea, Victoria; Gutknecht, Norbert

    2016-03-01

    Backgrounds: Er,Cr:YSGG (2780nm) and diode (940 nm) lasers can be used adjacent to the conventional periodontal treatment as minimally invasive non-surgical devices. Aim: To describe the short-term clinical outcomes by combining Er,Cr:YSGG (2780nm) and diode 940 nm lasers in non-surgical periodontal treatment. Materials and methods: A total of 10 patients with periodontal disease (mild, moderate, severe) - 233 teeth and 677 periodontal pockets ranging from 4 mm to 12 mm - were treated with Er,Cr:YSGG (2780nm) and diode (940 nm) lasers in adjunct to manual and piezoelectric scaling and root planning (SRP). Periodontal parameters such as mean probing depth (PD), mean clinical attachment level (CAL) and mean bleeding on probing (BOP) were evaluated at baseline and 6 months after the laser treatment using an electronic periodontal chart. Results: At baseline, the mean PD was 4.06 ± 1.06 mm, mean CAL was 4.56 ± 1.43 mm, and mean BOP was 43.8 ± 23.84 %. At 6 months after the laser supported periodontal treatments the mean PD was 2.6 ± 0.58 mm (p laser wavelengths in adjunct to SRP offers significant improvements of periodontal clinical parameters such as PD, CAL and BOP. Keywords: Laser supported periodontal treatment concept, Er,Cr:YSGG and diode 940nm lasers, Scaling and root planning, Minimally invasive non-surgical device

  18. Comparative analysis of the effect of the GaAlAs laser irradiation in 780 nm and 660 nm in the hypersensitive dentin

    International Nuclear Information System (INIS)

    Yuan, Sun Chien

    2003-01-01

    This study was to evaluate and compare the effects of the low intensity in laser radiation among GaAlAs 780 nm and GaAlAs 660 nm. The main proposal is to verify if there is any difference of the effects or results in low intensity laser application treatment of hypersensitive dentin, keeping the same parameters, only differing in wavelength. The samples were distributed in two groups. Group A 90 cases, treated with GaAlAs 780 nm and group B irradiated with GaAlAs 660 nm with a total of 76 cases analyzed. The results of application with GaAlAs 660 nm and GaAlAs 780 nm do not differ statistically. Which means using any one of the irradiation gives the same results. However can be noted that the response of reduction of hypersensitivity is faster with the radiation of GaAlAs 780 nm, but the results after three applications is the same for both types of radiation. (author)

  19. Comparative mutagenesis and interaction between near-ultraviolet (313- to 405-nm) and far-ultraviolet (254-nm) radiation in Escherichia coli strains with differing repair capabilities

    International Nuclear Information System (INIS)

    Turner, M.A.; Webb, R.B.

    1981-01-01

    Comparative mutagenesis and possible synergistic interaction between broad-spectrum (313- to 405-nm) near-ultraviolet (black light bulb [BLB]) radiation and 254-nm radiation were studied in Escherichia coli strains WP2 (wild type), WP2s (uvrA), WP10 (recA), WP6 (polA), WP6s (polA uvrA), WP100 (uvrA recA), and WP5 (lexA). With BLB radiation, strains WP2s and WP6s demonstrated a high level of mutagenesis, whereas strains WP2, WP5, WP6, WP10, and WP100 did not demonstrate significant mutagenesis. In contrast, 254-nm radiation was mutagenic in strains WP2, WP2s, WP6, and WP6s, but strains WP5, WP10, and WP100 were not significantly mutated. The absence of mutagenesis by BLB radiation in lexA and recA strains WP10, WP5, and WP100 suggests that lex + rec + repair may play a major role in mutagenesis by both BLB and 254-nm radiation. The hypothesis that BLB radiation selectively inhibits rec + lex + repair was tested by sequential BLB-254 nm radiation. With strain WP2, a fluence of 30 J/m 2 at 254 nm induced trp + revertants at a frequency of 15 x 10 -6 . However, when 10 5 J/m 2 or more BLB radiation preceded the 254-nm exposure, no trp + revertants could be detected. A similar inhibition of 254-nm mutagenesis was observed with strain WP6 (polA). However, strains WP2s (uvrA) and WP6s (polA uvrA) showed enhanced 254-nm mutagenesis when a prior exposure to BLB radiation was given

  20. Isotopomer fractionation during photolysis of nitrous oxide by ultraviolet of 206 to 210 nm

    International Nuclear Information System (INIS)

    Toyoda, S.; Yoshida, N.; Suzuki, T.; Tsuji, K.; Shibuya, K.

    2002-01-01

    Nitrous oxide (N 2 O) is an important trace gas in the stratospheric chemistry as well as in the tropospheric radiative balance. Although there have been observations on the distribution of N 2 O in the atmosphere and its flux from individual sources, the global N 2 O budget is not fully understood. The isotopic information of N 2 O has been useful for constraining the N 2 O cycle since each source and sink has its own isotopic signature and isotope fractionation that is unique to the process. We have recently developed a method to determine isotopomers of N 2 O and showed that intramolecular distribution of 15 N is a parameter that has more fundamental and sensitive information than bulk 15 N abundance for constraining the atmospheric N 2 O budget. Here, we report the fractionation of isotopomers during ultraviolet photolysis of N 2 O in a 206 to 210 nm region. The fractionation factors are different among isotopomers and the site preference between two nitrogen isotopomers becomes larger along with the photolysis. The isotopomer fractionation factors of this representative wavelength are close to the apparent fractionation factors observed in the stratosphere indicating ultraviolet photolysis in the stratosphere is the dominant sink of N 2 O. Sources of atmospheric N 2 O including terrestrial and oceanic biological processes, agricultural activities, industrial formation and fossil fuel combustion are expected to be characterized to better constrain the global budget of N 2 O. (author)

  1. Clean-up progress at the SNL/NM Classified Waste Landfill

    International Nuclear Information System (INIS)

    Slavin, P.J.; Galloway, R.B.

    1999-01-01

    The Sandia National Laboratories/New Mexico (SNL/NM)Environmental Restoration Project is currently excavating the Classified Waste Landfill in Technical Area II, a disposal area for weapon components for approximately 40 years until it closed in 1987. Many different types of classified parts were disposed in unlined trenches and pits throughout the course of the landfill's history. A percentage of the parts contain explosives and/or radioactive components or contamination. The excavation has progressed backward chronologically from the last trenches filled through to the earlier pits. Excavation commenced in March 1998, and approximately 75 percent of the site (as defined by geophysical anomalies) has been completed as of November 1999. The material excavated consists primarily of classified weapon assemblies and related components, so disposition must include demilitarization and sanitization. This has resulted in substantial waste minimization and cost avoidance for the project as upwards of 90 percent of the classified materials are being demilitarized and recycled. The project is using field screening and lab analysis in conjunction with preliminary and in-process risk assessments to characterize soil and make waste determinations in a timely a fashion as possible. Challenges in waste management have prompted the adoption of innovative solutions. The hand-picked crew (both management and field staff) and the ability to quickly adapt to changing conditions has ensured the success of the project. The current schedule is to complete excavation in July 2000, with follow-on verification sampling, demilitarization, and waste management activities following

  2. Nuclear installations sites safety

    International Nuclear Information System (INIS)

    Barber, P.; Candes, P.; Duclos, P.; Doumenc, A.; Faure, J.; Hugon, J.; Mohammadioun, B.

    1988-11-01

    This report is divided into ten parts bearing: 1 Safety analysis procedures for Basis Nuclear Installations sites (BNI) in France 2 Site safety for BNI in France 3 Industrial and transport activities risks for BNI in France 4 Demographic characteristics near BNI sites in France 5 Meteorologic characteristics of BNI sites in France 6 Geological aspects near the BNI sites in France 7 Seismic studies for BNI sites in France 8 Hydrogeological aspects near BNI sites in France 9 Hydrological aspects near BNI sites in France 10 Ecological and radioecological studies of BNI sites in France [fr

  3. Social Media Sites

    Science.gov (United States)

    Media Sites Site Registration Contact Us Search AF.mil: Home > AF Sites > Social Media Sites Social Media Welcome to the Air Force social media directory! The directory is a one-stop shop of official Air Force social media pages across various social media sites. Social media is all about

  4. Peculiarities of near-ultraviolet (365 nm) and visible light effects in Paramecium Caudatum cells

    International Nuclear Information System (INIS)

    Samoilova, K.A.; Sushchenko, N.B.

    1977-01-01

    After treatment with 365 nm or visible light Paramecium caudatum cells fail to divide and die shortly after irradiation; no death occurs long after irradiation, as well as after several cell cycles, unlike the situation after the action of 254 nm or 300-380 nm. Irradiation inhibits mainly the first cell cycle following which the recovery of cells starts. Thus no after-effects take place after the action of 365 nm and visible light, and the patterns of their effects are rather similar. The photoreactivation of damages induced by 365 nm is quite small, being about 2 times less than that for 254 nm and 300-380 nm. Similarity of the action of 254, 300-380, 365 nm and visible light was established by the stimulation of cell division by low doses and increase in viability of infusoria from cultures with low survival and depressed rate of multiplication. This effect of 365 nm is not eliminated by visible light; moreover, the latter promotes the 'therapeutic' effect of the 365 nm line. (author)

  5. The generation of a continuous-wave Nd:YVO4/LBO laser at 543 nm by direct in-band diode pumping at 888 nm

    International Nuclear Information System (INIS)

    Fu, S C; Wang, X; Chu, H

    2013-01-01

    We report the generation of a green laser at 543 nm by intracavity frequency doubling of the continuous-wave (cw) laser operation of a 1086 nm Nd:YVO 4 laser under 888 nm diode pumping into the emitting level 4 F 3/2 . An LiB 3 O 5 (LBO) crystal, cut for critical type I phase matching at room temperature, is used for the laser second-harmonic generation. At an incident pump power of 17.8 W, as high as 4.53 W cw output power at 543 nm is achieved. The optical-to-optical conversion efficiency is up to 25.4%, and the fluctuation of the green output power is better than 2.3% in a 30 min period. (paper)

  6. Sulphur abundances in halo giants from the [S ı] line at 1082 nm and the [S ı] triplet around 1045 nm

    DEFF Research Database (Denmark)

    Jönsson, H.; Ryde, N.; Nissen, Poul Erik

    2011-01-01

    to clarify this situation by measuring the sulphur abundance in a sample of halo giants using two diagnostics: the S i triplet around 1045 nm and the [S i] line at 1082 nm. The latter of the two is not believed to be sensitive to non-LTE effects. We can thereby minimize the uncertainties in the diagnostic...... used and estimate the usefulness of the triplet for the sulphur determination in halo K giants. We will also be able to compare our sulphur abundance differences from the two diagnostics with the expected non-LTE effects in the 1045 nm triplet previously calculated by others. Methods. High...... diagnostics using tailored 1D model atmospheres and relying on non-LTE corrections from the litterature. Effects of convective inhomogeneities in the stellar atmospheres are investigated. Results. The sulphur abundances derived from both the [S i] line and the non-LTE corrected 1045 nm triplet favor a flat...

  7. Bilirubin isomer distribution in jaundiced neonates during phototherapy with LED light centered at 497 nm (turquoise) vs. 459 nm (blue).

    Science.gov (United States)

    Ebbesen, Finn; Madsen, Poul H; Vandborg, Pernille K; Jakobsen, Lasse H; Trydal, Torleif; Vreman, Hendrik J

    2016-10-01

    Phototherapy using blue light is the treatment of choice worldwide for neonatal hyperbilirubinemia. However, treatment with turquoise light may be a desirable alternative. Therefore, the aim of this randomized, controlled study was to compare the bilirubin isomer distribution in serum of jaundiced neonates after 24 h of therapy with narrow-band (LED) light centered at 497 nm (turquoise) vs. 459 nm (blue), of essentially equal irradiance. Eighty-three neonates (≥33 wk gestational age) with uncomplicated hyperbilirubinemia were included in the study. Forty neonates were exposed to light centered at 497 nm and 43 infants with light centered at 459 nm. Irradiances were 5.2 × 10(15) and 5.1 × 10(15) photons/cm(2)/s, respectively. After 24 h of treatment no significant differences in serum concentrations of total bilirubin isomers and Z,Z-bilirubin were observed between the 2 groups. Interestingly, concentrations of Z,E-bilirubin, and thus also total bilirubin isomers formed during therapy, were highest for infants receiving light centered at 459 nm, while the concentration of E,Z-bilirubin was highest for those receiving light centered at 497 nm. No significant difference was found between concentrations of E,Z-lumirubin. Therapy with LED light centered at 497 nm vs. 459 nm, applied with equal irradiance on the infants, resulted in a different distribution of bilirubin isomers in serum.

  8. First demonstration of InGaP/InAlGaP based 608nm orange laser and 583nm yellow superluminescent diode

    KAUST Repository

    Majid, Mohammed Abdul

    2015-11-12

    We report on the first demonstration of InGaP/InAlGaP based orange semiconductor laser (OSL) and yellow superluminescent diode (YSLD) emitting at a wavelength of 608nm and 583nm respectively. The total output power of YSLD is ∼4.5mW which is the highest ever reported power on this material system at room-temperature.

  9. Comparison of the effects of 665 nm low level diode Laser Hat versus and a combination of 665 nm and 808nm low level diode Laser Scanner of hair growth in androgenic alopecia.

    Science.gov (United States)

    Barikbin, Behrooz; Khodamrdi, Zeinab; Kholoosi, Leila; Akhgri, Mohammad Reza; Haj Abbasi, Majid; Hajabbasi, Mojgan; Razzaghi, Zahra; Akbarpour, Samaneh

    2017-05-17

    This study aimed to evaluate the effectiveness of a combined set of low level diode laser scanner (665 nm and 808nm) on hair growth, and assessment of safety and effectiveness of a new laser scanner on hair growth treatment procedure in androgenic alopecia. 90 patients (18 to 70 years) with androgenic alopecia were randomized into three groups. The first group (n=30) received 655 nm red light using laser hat, the second group (n=30) received 655 nm red laser plus 808 nm infrared laser using a laser scanner of hair growth device (with the patent number: 77733) and the third group (n=30) received no laser as the control group. Patients in laser scanner group had better results and showed a higher increase in terminal hair density compared with laser hat group (mean of 9.61 versus 9.16 per cm 2 ). We found significant decrease in terminal hair density from baseline in control group (mean -1.8 per cm 2 , plaser scanner of the hair growth group compared with laser hat and the control group. The study showed that treatment with new laser devise had a promising result without any observable adverse effects.

  10. Comparative Study of the Detection of Chromium Content in Rice Leaves by 532 nm and 1064 nm Laser-Induced Breakdown Spectroscopy

    Directory of Open Access Journals (Sweden)

    Jiyu Peng

    2018-02-01

    Full Text Available Fast detection of toxic metals in crops is important for monitoring pollution and ensuring food safety. In this study, laser-induced breakdown spectroscopy (LIBS was used to detect the chromium content in rice leaves. We investigated the influence of laser wavelength (532 nm and 1064 nm excitation, along with the variations of delay time, pulse energy, and lens-to-sample distance (LTSD, on the signal (sensitivity and stability and plasma features (temperature and electron density. With the optimized experimental parameters, univariate analysis was used for quantifying the chromium content, and several preprocessing methods (including background normalization, area normalization, multiplicative scatter correction (MSC transformation and standardized normal variate (SNV transformation were used to further improve the analytical performance. The results indicated that 532 nm excitation showed better sensitivity than 1064 nm excitation, with a detection limit around two times lower. However, the prediction accuracy for both excitation wavelengths was similar. The best result, with a correlation coefficient of 0.9849, root-mean-square error of 3.89 mg/kg and detection limit of 2.72 mg/kg, was obtained using the SNV transformed signal (Cr I 425.43 nm induced by 532 nm excitation. The results indicate the inspiring capability of LIBS for toxic metals detection in plant materials.

  11. NM WAIDS: A PRODUCED WATER QUALITY AND INFRASTRUCTURE GIS DATABASE FOR NEW MEXICO OIL PRODUCERS

    Energy Technology Data Exchange (ETDEWEB)

    Martha Cather; Robert Lee; Ibrahim Gundiler; Andrew Sung; Naomi Davidson; Ajeet Kumar Reddy; Mingzhen Wei

    2003-04-01

    The New Mexico Water and Infrastructure Data System (NM WAIDS) seeks to alleviate a number of produced water-related issues in southeast New Mexico. The project calls for the design and implementation of a Geographical Information System (GIS) and integral tools that will provide operators and regulators with necessary data and useful information to help them make management and regulatory decisions. The major components of this system are: (1) databases on produced water quality, cultural and groundwater data, oil pipeline and infrastructure data, and corrosion information, (2) a web site capable of displaying produced water and infrastructure data in a GIS or accessing some of the data by text-based queries, (3) a fuzzy logic-based, site risk assessment tool that can be used to assess the seriousness of a spill of produced water, and (4) a corrosion management toolkit that will provide operators with data and information on produced waters that will aid them in deciding how to address corrosion issues. The various parts of NM WAIDS will be integrated into a website with a user-friendly interface that will provide access to previously difficult-to-obtain data and information. Primary attention during the first six months of this project has been focused on creating the water quality databases for produced water and surface water, along with collection of corrosion information and building parts of the corrosion toolkit. Work on the project to date includes: (1) Creation of a water quality database for produced water analyses. The database was compiled from a variety of sources and currently has over 4000 entries for southeast New Mexico. (2) Creation of a web-based data entry system for the water quality database. This system allows a user to view, enter, or edit data from a web page rather than having to directly access the database. (3) Creation of a semi-automated data capturing system for use with standard water quality analysis forms. This system improves the

  12. NM WAIDS: A PRODUCED WATER QUALITY AND INFRASTRUCTURE GIS DATABASE FOR NEW MEXICO OIL PRODUCERS

    Energy Technology Data Exchange (ETDEWEB)

    Martha Cather; Robert Lee; Ibrahim Gundiler; Andrew Sung

    2003-09-24

    The New Mexico Water and Infrastructure Data System (NM WAIDS) seeks to alleviate a number of produced water-related issues in southeast New Mexico. The project calls for the design and implementation of a Geographical Information System (GIS) and integral tools that will provide operators and regulators with necessary data and useful information to help them make management and regulatory decisions. The major components of this system are: (1) Databases on produced water quality, cultural and groundwater data, oil pipeline and infrastructure data, and corrosion information. (2) A web site capable of displaying produced water and infrastructure data in a GIS or accessing some of the data by text-based queries. (3) A fuzzy logic-based, site risk assessment tool that can be used to assess the seriousness of a spill of produced water. (4) A corrosion management toolkit that will provide operators with data and information on produced waters that will aid them in deciding how to address corrosion issues. The various parts of NM WAIDS will be integrated into a website with a user-friendly interface that will provide access to previously difficult-to-obtain data and information. Primary attention during the first six months of this project was focused on creating the water quality databases for produced water and surface water, along with collecting of corrosion information and building parts of the corrosion toolkit. Work on the project to date includes: (1) Creation of a water quality database for produced water analyses. The database was compiled from a variety of sources and currently has over 7000 entries for New Mexico. (2) Creation of a web-based data entry system for the water quality database. This system allows a user to view, enter, or edit data from a web page rather than having to directly access the database. (3) Creation of a semi-automated data capturing system for use with standard water quality analysis forms. This system improves the accuracy and speed

  13. NM23 proteins: innocent bystanders or local energy boosters for CFTR?

    Science.gov (United States)

    Muimo, Richmond; Alothaid, Hani Mm; Mehta, Anil

    2018-03-01

    NM23 proteins NDPK-A and -B bind to the cystic fibrosis (CF) protein CFTR in different ways from kinases such as PKA, CK2 and AMPK or linkers to cell calcium such as calmodulin and annexins. NDPK-A (not -B) interacts with CFTR through reciprocal AMPK binding/control, whereas NDPK-B (not -A) binds directly to CFTR. NDPK-B can activate G proteins without ligand-receptor coupling, so perhaps NDPK-B's binding influences energy supply local to a nucleotide-binding site (NBD1) needed for CFTR to function. Curiously, CFTR (ABC-C7) is a member of the ATP-binding cassette (ABC) protein family that does not obey 'clan rules'; CFTR channels anions and is not a pump, regulates disparate processes, is itself regulated by multiple means and is so pleiotropic that it acts as a hub that orchestrates calcium signaling through its consorts such as calmodulin/annexins. Furthermore, its multiple partners make CFTR dance to different tunes in different cellular and subcellular locations as it recycles from the plasma membrane to endosomes. CFTR function in airway apical membranes is inhibited by smoking which has been dubbed 'acquired CF'. CFTR alone among family members possesses a trap for other proteins that it unfurls as a 'fish-net' and which bears consensus phosphorylation sites for many protein kinases, with PKA being the most canonical. Recently, the site of CFTR's commonest mutation has been proposed as a knock-in mutant that alters allosteric control of kinase CK2 by log orders of activity towards calmodulin and other substrates after CFTR fragmentation. This link from CK2 to calmodulin that binds the R region invokes molecular paths that control lumen formation, which is incomplete in the tracheas of some CF-affected babies. Thus, we are poised to understand the many roles of NDPK-A and -B in CFTR function and, especially lumen formation, which is defective in the gut and lungs of many CF babies.

  14. Ocean Disposal Site Monitoring

    Science.gov (United States)

    EPA is responsible for managing all designated ocean disposal sites. Surveys are conducted to identify appropriate locations for ocean disposal sites and to monitor the impacts of regulated dumping at the disposal sites.

  15. Promoting Your Web Site.

    Science.gov (United States)

    Raeder, Aggi

    1997-01-01

    Discussion of ways to promote sites on the World Wide Web focuses on how search engines work and how they retrieve and identify sites. Appropriate Web links for submitting new sites and for Internet marketing are included. (LRW)

  16. Particle Physics Education Sites

    Science.gov (United States)

    back to home page Particle Physics Education Sites quick reference Education and Information - National Laboratory Education Programs - Women and Minorities in Physics - Other Physics Sites - Physics Alliance - Accelerators at National Laboratories icon Particle Physics Education and Information sites: top

  17. CMOS-NEMS Copper Switches Monolithically Integrated Using a 65 nm CMOS Technology

    Directory of Open Access Journals (Sweden)

    Jose Luis Muñoz-Gamarra

    2016-02-01

    Full Text Available This work demonstrates the feasibility to obtain copper nanoelectromechanical (NEMS relays using a commercial complementary metal oxide semiconductor (CMOS technology (ST 65 nm following an intra CMOS-MEMS approach. We report experimental demonstration of contact-mode nano-electromechanical switches obtaining low operating voltage (5.5 V, good ION/IOFF (103 ratio, abrupt subthreshold swing (4.3 mV/decade and minimum dimensions (3.50 μm × 100 nm × 180 nm, and gap of 100 nm. With these dimensions, the operable Cell area of the switch will be 3.5 μm (length × 0.2 μm (100 nm width + 100 nm gap = 0.7 μm2 which is the smallest reported one using a top-down fabrication approach.

  18. Diode-side-pumped 131 W, 1319 nm single-wavelength cw Nd:YAG laser.

    Science.gov (United States)

    Haiyong, Zhu; Ge, Zhang; Chenghui, Huang; Yong, Wei; Lingxiong, Huang; Jing, Chen; Weidong, Chen; Zhenqiang, Chen

    2007-01-20

    A diode-side-pumped high-power 1319 nm single-wavelength Nd:YAG continuous wave (cw) laser is described. Through reasonable coating design of the cavity mirrors, the 1064 nm strongest line as well as the 1338 nm one have been successfully suppressed. The laser output powers corresponding to four groups of different output couplers operating at 1319 nm single wavelength have been compared. The output coupler with the transmission T=5.3% has the highest output power, and a 131 W cw output power was achieved at the pumping power of 555 W. The optical-optical conversion efficiency is 23.6%, and the slope efficiency is 46%. The output power is higher than the total output power of the dual-wavelength laser operating at 1319 nm and 1338 nm in the experiment.

  19. 308-nm excimer lamp for the treatment of alopecia areata: Clinical trial on 16 cases

    Directory of Open Access Journals (Sweden)

    Akiko Ohtsuki

    2013-01-01

    Full Text Available Background: Alopecia areata (AA is considered as a T-cell mediated autoimmune disorder. The 308-nm excimer laser is thought to be capable of inducing T-cell apoptosis in vitro, suggesting that the 308-nm excimer lamp (not laser might be effective for the treatment of AA. We examined the effectiveness of the 308-nm excimer lamp for treating AA. Materials and Methods: We treated 16 patients with single AA and multiple AA (MAA. The lesions were irradiated with a 308-nm excimer lamp at 2-week intervals. Results: Hair regrowth was observed in 14 patients. Among them, 10 patients showed more than 50% hair re-growth. Our results suggested that the 308-nm excimer lamp system is effective and safe for the treatment of single AA and MAA. Conclusion: Our results suggest that the 308-nm excimer lamp is a good therapeutic alternative without serious side effect for treating AA.

  20. Raman Spectra and Bulk Modulus of Nanodiamond in a Size Interval of 2-5 nm

    Science.gov (United States)

    Popov, Mikhail; Churkin, Valentin; Kirichenko, Alexey; Denisov, Viktor; Ovsyannikov, Danila; Kulnitskiy, Boris; Perezhogin, Igor; Aksenenkov, Viktor; Blank, Vladimir

    2017-10-01

    Nanodiamond in a 2-5-nm size interval (which is typical for an appearance of quantum confinement effect) show Raman spectra composed of 3 bands at 1325, 1600, and 1500 cm-1 (at the 458-nm laser excitation) which shifts to 1630 cm-1 at the 257-nm laser excitation. Contrary to sp2-bonded carbon, relative intensities of the bands do not depend on the 458- and 257-nm excitation wavelengths, and a halfwidth and the intensity of the 1600 cm-1 band does not change visibly under pressure at least up to 50 GPa. Bulk modulus of the 2-5-nm nanodiamond determined from the high-pressure study is around 560 GPa. Studied 2-5-nm nanodiamond was purified from contamination layers and dispersed in Si or NaCl.

  1. Metastable Magnesium fluorescence spectroscopy using a frequency-stabilized 517 nm laser

    DEFF Research Database (Denmark)

    He, Ming; Jensen, Brian B; Therkildsen, Kasper T

    2009-01-01

    We present a laser operating at 517 nm for our Magnesium laser-cooling and atomic clock project. A two-stage Yb-doped fiber amplifier (YDFA) system generates more than 1.5 W of 1034 nm light when seeded with a 15 mW diode laser. Using a periodically poled lithium niobate (PPLN) waveguide, we obta...... obtained more than 40 mW of 517 nm output power by single pass frequency doubling. In addition, fluorescence spectroscopy of metastable magnesium atoms could be used to stabilize the 517 nm laser to an absolute frequency within 1 MHz.......We present a laser operating at 517 nm for our Magnesium laser-cooling and atomic clock project. A two-stage Yb-doped fiber amplifier (YDFA) system generates more than 1.5 W of 1034 nm light when seeded with a 15 mW diode laser. Using a periodically poled lithium niobate (PPLN) waveguide, we...

  2. Densification of ∼5 nm-thick SiO_2 layers by nitric acid oxidation

    International Nuclear Information System (INIS)

    Choi, Jaeyoung; Joo, Soyeong; Park, Tae Joo; Kim, Woo-Byoung

    2017-01-01

    Highlights: • Leakage current density of the commercial PECVD grown ∼5 nm SiO_2 layer has been decreased about three orders of magnitude by densification. • The densification of SiO_2 layer is achieved by high oxidation ability of O·. • Densities of suboxide, fixed charge (N_f) and defect state (N_d) in SiO_2/Si interface are decreased by NAOS and PMA. • Tunneling barrier height (Φ_t) is increased because of the increase of atomic density in SiO_2 layer. - Abstract: Low-temperature nitric acid (HNO_3) oxidation of Si (NAOS) has been used to improve the interface and electrical properties of ∼5 nm-thick SiO_2/Si layers produced by plasma-enhanced chemical vapor deposition (PECVD). Investigations of the physical properties and electrical characteristics of these thin films revealed that although their thickness is not changed by NAOS, the leakage current density at a gate bias voltage of −1 V decreases by about two orders of magnitude from 1.868 × 10"−"5 A/cm"2. This leakage current density was further reduced by post-metallization annealing (PMA) at 250 °C for 10 min in a 5 vol.% hydrogen atmosphere, eventually reaching a level (5.2 × 10"−"8 A/cm"2) approximately three orders of magnitude less than the as-grown SiO_2 layer. This improvement is attributed to a decrease in the concentration of suboxide species (Si"1"+, Si"2"+ and Si"3"+) in the SiO_2/Si interface, as well as a decrease in the equilibrium density of defect sites (N_d) and fixed charge density (N_f). The barrier height (Φ_t) generated by a Poole-Frenkel mechanism also increased from 0.205 to 0.371 eV after NAOS and PMA. The decrease in leakage current density is therefore attributed to a densification of the SiO_2 layer in combination with the removal of OH species and increase in interfacial properties at the SiO_2/Si interface.

  3. Spectroscopy and decay kinetics of Pr3+-doped chloride crystals for 1300-nm optical amplifiers

    International Nuclear Information System (INIS)

    Page, R.H.; Schaffers, K.I.; Wilke, G.D.

    1995-01-01

    Several Pr 3+ -doped chloride crystals have been tested spectroscopically for suitability as 1300-nm optical amplifiers operating on the 1 G 4 - 3 H 5 transition. 1 G 4 lifetimes are much longer than in fluoride hosts, ranging up to 1300 μsec and suggesting a near-unity luminescence quantum yield. Emission spectra are typically broad (FWHM ∼ 70 nm) and include the 1310-nm zero-dispersion wavelength of standard telecommunications fiber

  4. Semiconductor lasers with a continuous tuning range above 100 nm in the nearest IR spectral region

    Energy Technology Data Exchange (ETDEWEB)

    Kostin, Yu O; Lobintsov, A A; Shramenko, M V [OOO ' Opton' , Moscow (Russian Federation); Ladugin, M A; Marmalyuk, A A [Open Joint-Stock Company M.F. Stel' makh Polyus Research Institute, Moscow (Russian Federation); Chamorovsky, A Yu [Superlum Ltd., Unit B3, Fota Point Enterprise Park, Carrigtwohill, Co Cork (Ireland); Yakubovich, S D [Moscow State Institute of Radio-Engineering, Electronics and Automation (Technical University), Moscow (Russian Federation)

    2015-08-31

    We have developed two new types of lasers based on quantum-confined semiconductor optical amplifiers with an acousto-optic tunable filter in an external fibre ring cavity. The lasers offer continuous wavelength tuning ranges from 780 to 885 and from 880 to 1010 nm, 20 mW of cw output power, and a tuning rate up to 10{sup 4} nm s{sup -1} at an instantaneous spectral linewidth less than 0.1 nm. (lasers)

  5. Hanford Site Development Plan

    Energy Technology Data Exchange (ETDEWEB)

    Rinne, C.A.; Curry, R.H.; Hagan, J.W.; Seiler, S.W.; Sommer, D.J. (Westinghouse Hanford Co., Richland, WA (USA)); Yancey, E.F. (Pacific Northwest Lab., Richland, WA (USA))

    1990-01-01

    The Hanford Site Development Plan (Site Development Plan) is intended to guide the short- and long-range development and use of the Hanford Site. All acquisition, development, and permanent facility use at the Hanford Site will conform to the approved plan. The Site Development Plan also serves as the base document for all subsequent studies that involve use of facilities at the Site. This revision is an update of a previous plan. The executive summary presents the highlights of the five major topics covered in the Site Development Plan: general site information, existing conditions, planning analysis, Master Plan, and Five-Year Plan. 56 refs., 67 figs., 31 tabs.

  6. Hanford Site Development Plan

    International Nuclear Information System (INIS)

    Rinne, C.A.; Curry, R.H.; Hagan, J.W.; Seiler, S.W.; Sommer, D.J.; Yancey, E.F.

    1990-01-01

    The Hanford Site Development Plan (Site Development Plan) is intended to guide the short- and long-range development and use of the Hanford Site. All acquisition, development, and permanent facility use at the Hanford Site will conform to the approved plan. The Site Development Plan also serves as the base document for all subsequent studies that involve use of facilities at the Site. This revision is an update of a previous plan. The executive summary presents the highlights of the five major topics covered in the Site Development Plan: general site information, existing conditions, planning analysis, Master Plan, and Five-Year Plan. 56 refs., 67 figs., 31 tabs

  7. [Comparative investigation of underwater-LIBS using 532 and 1 064 nm lasers].

    Science.gov (United States)

    Song, Jiao-Jian; Tian, Ye; Lu, Yuan; Li, Ying; Zheng, Rong-Er

    2014-11-01

    With the hope of applying laser induced breakdown spectroscopy (LIBS) to the ocean applications, the laser energy at 532 and 1 064 nm wavelength with 3 and 40 mj respectively was used, which was near their breakdown threshold. Extensive experimental investigations of LIBS from CaCl2 water solution were carried out in this paper using different laser wavelengths of 532 and 1 064 nm. The obtained results show that compared with the 532 nm laser, the 1 064 nm laser can induce the plasma in water with higher emission intensity and longer lifetime, while the reproducibility of LIBS signal under 1 064 nm laser is poorer. On the other hand, due to the different attenuation ratios of 532 and 1 064 nm laser energies in water, the LIBS signal of 1 064 nm laser decreases a lot within the transmission distance range 2-5 cm, while LIBS signal of 532 nm remains the same, because that the wavelength of 532 nm lies in the "transmission window" of the water solution. This study will provide valuable design considerations for the development of LIBS-sea system in near future.

  8. Bismuth-doped fibre amplifier operating between 1600 and 1800 nm

    Energy Technology Data Exchange (ETDEWEB)

    Firstov, S V; Alyshev, S V; Riumkin, K E; Mel' kumov, M A; Dianov, E M [Fiber Optics Research Center, Russian Academy of Sciences, Moscow (Russian Federation); Khopin, V F; Gurjanov, A N [G.G.Devyatykh Institute of Chemistry of High-Purity Substances, Russian Academy of Sciences, Nizhnii Novgorod (Russian Federation)

    2015-12-31

    We report the first bismuth-doped fibre amplifier operating between 1600 and 1800 nm, which utilises bidirectional pumping (co-propagating and counter-propagating pump beams) by laser diodes at a wavelength of 1550 nm. The largest gain coefficient of the amplifier is 23 dB, at a wavelength of 1710 nm. It has a noise figure of 7 dB, 3-dB gain bandwidth of 40 nm and gain efficiency of 0.1 dB mW{sup -1}. (letters)

  9. Chaos, Consternation and CALIPSO Calibration: New Strategies for Calibrating the CALIOP 1064 nm Channel

    Science.gov (United States)

    Vaughan, Mark; Garnier, Anne; Liu, Zhaoyan; Josset, Damien; Hu, Yongxiang; Lee, Kam-Pui; Hunt, William; Vernier, Jean-Paul; Rodier, Sharon; Pelon, Jaques; hide

    2012-01-01

    The very low signal-to-noise ratios of the 1064 nm CALIOP molecular backscatter signal make it effectively impossible to employ the "clear air" normalization technique typically used to calibrate elastic back-scatter lidars. The CALIPSO mission has thus chosen to cross-calibrate their 1064 nm measurements with respect to the 532 nm data using the two-wavelength backscatter from cirrus clouds. In this paper we discuss several known issues in the version 3 CALIOP 1064 nm calibration procedure, and describe the strategies that will be employed in the version 4 data release to surmount these problems.

  10. SITE COMPREHENSIVE LISTING (CERCLIS) (Superfund) - NPL Sites

    Data.gov (United States)

    U.S. Environmental Protection Agency — National Priorities List (NPL) Sites - The Comprehensive Environmental Response, Compensation and Liability Information System (CERCLIS) (Superfund) Public Access...

  11. Superfund Site Information - Site Sampling Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — This asset includes Superfund site-specific sampling information including location of samples, types of samples, and analytical chemistry characteristics of...

  12. Site Closure Strategy Model for Creosote Site

    International Nuclear Information System (INIS)

    Coll, F.R.; Gray, D.R.

    2009-01-01

    In conjunction with RCRA site corrective action at an active wood preserving facility, a risk-based site closure strategy was developed and incorporated the performance of a dense non-aqueous phase liquid (DNAPL) source recovery remedy, a monitored natural attenuation (MNA) remedy for dissolved phase groundwater, and institutional controls. Innovative creosote DNAPL source recovery has been undertaken at the Site since 1998. Pooled creosote DNAPL is present 90 feet below ground within a transmissive sand and gravel aquifer with a saturated thickness of approximately 80 feet. The creosote DNAPL source is situated on the property boundary of the site and has generated a 1/2 mile off-site dissolved phase plume, creating significant NAPL management and remedial technology verification issues. To date, over 120,000 gallons of creosote DNAPL have been recovered from the subsurface utilizing a modified circulation well technology. A mass discharge flux protocol was developed to serve as a major performance metrics for the continuation of source removal efforts and to support the application of monitored natural attenuation as an associated remedial technology for groundwater. The mass removal success has supported the MNA remedy for dissolved phase groundwater and the associated development of institutional controls. The enacted site management strategy outlines the current and future risk management activities for the Site and represents an appropriate site closure strategy for the Site. (authors)

  13. Organic nanostructures on silicon, created with semitransparent polystyrene spheres and 248 nm laser pulses

    International Nuclear Information System (INIS)

    Rothe, Erhard W; Manke, Charles W; Piparia, Reema; Baird, Ronald J

    2008-01-01

    Arrays of nanostructures are made starting with a template of close-packed, polystyrene spheres on a silicon surface. The spheres are either 1.091 or 2.99 μm in diameter (d) and are of polystyrene (PS). They are irradiated with a pulse of either 308 or 248 nm light to which they are transparent and semitransparent, respectively. A transparent sphere with d = 1.091 μm diameter concentrates incident light onto a small substrate area. As has been previously reported, that creates silicon nanobumps that rise from circular craters. At 248 nm and d = 2.99 μm, the light energy is mainly absorbed, destroys the sphere, and leaves a shrunken mass (typically about 500 nm wide and 100 nm high) of organic material that is probably polystyrene and its thermal degradation products. At 248 nm and d = 1.091 μm, the residual organic structures are on the order of 300 nm wide and 100 nm high. A distinctive feature is that these organic structures are connected by filaments that are on the order of 50 nm wide and 10 nm high. Filaments form because the close-packed PS spheres expand into each other during the early part of the laser pulse, and then, as the main structures shrink, their viscoelasticity leads to threads between them. Our results with 248 nm and d = 1.091 μm differ from those described by Huang et al with 248 nm and d = 1.0 μm. Future studies might include the further effect of wavelength and fluence upon the process as well the use of other materials and the replacement of nanospheres by other focusing shapes, such as ellipsoids or rods

  14. 1300 nm and 890 nm OCT images of oral cancer tissue engineered models and biopsy samples offer complimentary performance (Conference Presentation)

    Science.gov (United States)

    Boadi, Joseph; Byers, Robert A.; Fernandes, Jon; Mittar, Shweta; Hearnden, Vanessa; Lu, Zenghai; MacNeil, Sheila; Thornhill, Martin; Murdoch, Craig; Hunter, Keith D.; McKechnie, Alasdair; Matcher, Stephen J.

    2016-02-01

    OCT has demonstrated great potential to non-invasively detect oral epithelial cancers, potentially guiding biopsy and surgical resection. On non-ophthalmic tissues the preferred illumination wavelength is 1300 nm. Previous studies on skin have shown that useful image data can also be obtained at shorter wavelengths, with systems at 1060 nm and 820 nm offering reduced depth penetration but higher contrast. Here we apply a similar comparison to tissue engineered models of oral cancer and also to human biopsy samples, generally finding a similar trend. 1300 nm multi-beam OCT (Michelson Diagnostics EX1301) visualises stromal structures and surface keratin more clearly, providing useful image contrast down to around 1 mm. This system was compared with an ultra-high resolution home-built system operating at 890 nm (2.5 micron resolution vs 7.5 micron axial resolution for the EX1301). The UHR system reveals epithelial features more clearly, especially in the DOK pre-invasive cell line model and the biopsy samples. The relative effects of center wavelength vs axial resolution in generating the differential, wavelength-dependent contrast are assessed and the OCT biopsy images are compared with contemporary histology.

  15. Nearly fully compressed 1053 nm pulses directly obtained from 800 nm laser-seeded photonic crystal fiber below zero dispersion point

    Science.gov (United States)

    Refaeli, Zaharit; Shamir, Yariv; Ofir, Atara; Marcus, Gilad

    2018-02-01

    We report a simple robust and broadly spectral-adjustable source generating near fully compressed 1053 nm 62 fs pulses directly out of a highly-nonlinear photonic crystal fiber. A dispersion-nonlinearity balance of 800 nm Ti:Sa 20 fs pulses was obtained initially by negative pre-chirping and then launching the pulses into the fibers' normal dispersion regime. Following a self-phase modulation spectral broadening, some energy that leaked below the zero dispersion point formed a soliton whose central wavelength could be tuned by Self-Frequency-Raman-Shift effect. Contrary to a common approach of power, or, fiber-length control over the shift, here we continuously varied the state of polarization, exploiting the Raman and Kerr nonlinearities responsivity for state of polarization. We obtained soliton pulses with central wavelength tuned over 150 nm, spanning from well below 1000 to over 1150 nm, of which we could select stable pulses around the 1 μm vicinity. With linewidth of > 20 nm FWHM Gaussian-like temporal-shape pulses with 62 fs duration and near flat phase structure we confirmed high quality pulse source. We believe such scheme can be used for high energy or high power glass lasers systems, such as Nd or Yb ion-doped amplifiers and systems.

  16. Ablative Fractional 10 600 nm Carbon Dioxide Laser Versus Non-ablative Fractional 1540 nm Erbium-Glass Laser in Egyptian Post-acne Scar patients.

    Science.gov (United States)

    Elsaie, Mohamed L; Ibrahim, Shady M; Saudi, Wael

    2018-01-01

    Introduction: Non-ablative fractional erbium-doped glass 1540 nm and fractional ablative 10600 nm carbon dioxide lasers are regarded as effective modalities for treating acne atrophic scars. In this study, we aimed to compare the effectiveness of fractional CO 2 laser and fractional nonablative 1540 nm erbium doped glass laser in treating post acne atrophic scars in Egyptian patients. Methods: Fifty-eight patients complaining of moderate and severe acne atrophic scars were randomly divided into 2 groups of 29 patients each. Both groups were subjected to 4 treatment sessions with 3 weeks interval and were followed up for 3 months. In group A, enrolled patient sreceived C2 laser, while in group B, patients were treated with 1540 nm erbium glass fractional laser. Results: Clinical assessment revealed that the mean grades of progress and improvement were higher with fractional 10600 nm CO2 laser but with non-significant difference between both treatments ( P = 0.1). The overall patients' satisfaction with both lasers were not significantly different ( P = 0.44). Conclusion: Both fractional ablative CO2 and fractional non-ablative erbium glass lasers are good modalities for treating acne scars with a high efficacy and safety profile and good patient satisfaction. The fractional ablative laser showed higher efficacy while non-ablative laser offered less pain and shorter downtime.

  17. Site specific information in site selection

    International Nuclear Information System (INIS)

    Aeikaes, T.; Hautojaervi, A.

    1998-01-01

    The programme for the siting of a deep repository for final disposal of spent nuclear fuel was started already in 1983 and is carried out today by Posiva Oy which continues the work started by Teollisuuden Voima Oy. The programme aims at site selection by the end of the year 2000. The programme has progressed in successive interim stages with defined goals. After an early phase for site identification, five sites were selected in 1987 for preliminary site characterisation. Three of these were selected and judged to be best suited for the more detailed characterisation in 1992. An additional new site was included into the programme based on a separate feasibility study in the beginning of 1997. Since the year 1983 several safety assessments together with technical plans of the facility have been completed. When approaching the site selection the needs for more detailed consideration of the site specific properties in the safety assessment have been increased. The Finnish regulator STUK has published a proposal for general safety requirements for the final disposal of spent nuclear fuel in Finland. This set of requirements has been projected to be used in conjunction of the decision making by the end 2000. Based on the site evaluation all sites can provide a stable environment and there is evidence that the requirements for the longevity of the canister can be fulfilled at each site. In this manner the four candidate sites do not differ too much from each other. The main difference between the sites is in the salinity of the deep groundwater. The significance of differences in the salinity for the long-term safety cannot be defined yet. The differences may contribute to the discussion of the longevity of the bentonite buffer and also to the modelling of the groundwater flow and transport. The use of the geosphere as a transport barrier is basically culminated on the questions about sparse but fast flow routes and 'how bad channeling can be'. To answer these questions

  18. Hanford Site Development Plan

    International Nuclear Information System (INIS)

    Hathaway, H.B.; Daly, K.S.; Rinne, C.A.; Seiler, S.W.

    1993-05-01

    The Hanford Site Development Plan (HSDP) provides an overview of land use, infrastructure, and facility requirements to support US Department of Energy (DOE) programs at the Hanford Site. The HSDP's primary purpose is to inform senior managers and interested parties of development activities and issues that require a commitment of resources to support the Hanford Site. The HSDP provides an existing and future land use plan for the Hanford Site. The HSDP is updated annually in accordance with DOE Order 4320.1B, Site Development Planning, to reflect the mission and overall site development process. Further details about Hanford Site development are defined in individual area development plans

  19. Summary pamphlet: 1995 site environmental report

    International Nuclear Information System (INIS)

    1996-01-01

    As required in U.S. Department of Energy (DOE) Order 5400.1, an Annual Site Environmental Report (ASER) has been prepared for Sandia National Laboratories/New Mexico (SNL/NM) for 1995. The ASER represents a key component of the DOE's effort to keep the public informed about environmental efforts and compliance status at SNL/NM. This booklett was prepared by the Environmental Operations Center of SNL/NM and reviewed by Community Relations and Risk Management. Suggestions were incorporated from the students of New Futures High School as a part of the Environmental Education Program. This work is supported by the DOE under Contract DE-AC04-94AL85000. A copy of the ASER can be obtained by calling the Environmental Monitoring and Reporting Department at 848-0927. This pamphlet provides a brief summary of the 1995 SNL/NM environmental programs and monitoring results. Additional copies of this pamphlet may be obtained by calling the number above

  20. Investigation of the impact of water absorption on retinal OCT imaging in the 1060 nm range

    DEFF Research Database (Denmark)

    Marschall, Sebastian; Pedersen, Christian; Andersen, Peter E.

    2012-01-01

    the optimal resolution by spectral shaping. As our results show, with currently available semiconductor-based light sources with up to 100–120 nm bandwidth centered close to 1060 nm, the resolution degradation caused by the water absorption spectrum is smaller than 10%, and it can be compensated by spectral...

  1. Effects of photoprotection and reversible inactivation of the yeast Candida guilliermondii, induced by 313 nm light

    International Nuclear Information System (INIS)

    Frajkin, G.Ya.; Pospelov, M.E.; Rubin, L.B.

    1976-01-01

    The results of studies on the effect of near uv light on the yeast Candida guilliermondii are presented. It was shown that certain doses of 313 nm light inactivated the yeast. The detailed affect is shown in the loss of the ability of the cells to form microcolonies and outwardly does not differ from inactivation caused by 254 nm uv. It was concluded that the cell destruction caused by the 313 nm light was not due to damage to DNA. Experiments in which yeast cells were inactivated by 313 nm light before plating on agar and held for some time in a non-nutrient medium permitted observation of recovery of their viability. A difference was shown in the level of repair of yeasts irradiated by 313 nm light (up to 100% recovery) and 254 nm light (60% recovery). The nature of the dependence of the photoprotection on the 313 nm light dose was determined. A decrease in photoprotection was noted, starting with 7x10 -7 einstein/cm 2 , with its complete disappearance upon further dose increase. It is suggested that, in this recovery of the yeast, some other, thus far unknown, mechanism participates. Data were obtained on the survival of yeast irradiated with lethal uv doses. Of special importance, in the authors' opinion, is the fact that, for the photoprotection effect to appear, some time is needed between actions of the 313 and 254 nm lights, which suggests a photoinduced formation in the yeast cells of compounds that protect them from lethal injury

  2. 32nm and below logic patterning using optimized illumination and double patterning

    Science.gov (United States)

    Smayling, Michael C.; Axelrad, Valery

    2009-03-01

    Line/space dimensions for 32nm generation logic are expected to be ~45-50nm at ~90-100nm pitch. It is likely that the node will begin at the upper end of the range, and then shrink by ~10% to a "28nm" node. For the lower end of the range, even with immersion scanners, the Rayleigh k1 factor is below 0.32. The 22nm logic node should begin with minimum pitches of approximately 70nm, requiring some form of double patterning to maintain k1 above 0.25. Logic patterning has been more difficult than NAND Flash patterning because random logic was designed with complete "freedom" compared to the very regular patterns used in memory. The logic layouts with bends and multiple pitches resulted in larger rules, un-optimized illumination, and a poorly understood process windows with little control of context-dependent "hot spots."[1] The introduction of logic design styles which use strictly one-directional lines for the critical levels now gives the opportunity for illumination optimization. Gridded Design Rules (GDR) have been demonstrated to give areacompetitive layouts at existing 90, 65, and 45nm logic nodes while reducing CD variability.[2] These benefits can be extended to <=32nm logic using selective double pass patterning.

  3. Ultrathin Nanocrystalline Diamond Films with Silicon Vacancy Color Centers via Seeding by 2 nm Detonation Nanodiamonds.

    Science.gov (United States)

    Stehlik, Stepan; Varga, Marian; Stenclova, Pavla; Ondic, Lukas; Ledinsky, Martin; Pangrac, Jiri; Vanek, Ondrej; Lipov, Jan; Kromka, Alexander; Rezek, Bohuslav

    2017-11-08

    Color centers in diamonds have shown excellent potential for applications in quantum information processing, photonics, and biology. Here we report chemical vapor deposition (CVD) growth of nanocrystalline diamond (NCD) films as thin as 5-6 nm with photoluminescence (PL) from silicon-vacancy (SiV) centers at 739 nm. Instead of conventional 4-6 nm detonation nanodiamonds (DNDs), we prepared and employed hydrogenated 2 nm DNDs (zeta potential = +36 mV) to form extremely dense (∼1.3 × 10 13 cm -2 ), thin (2 ± 1 nm), and smooth (RMS roughness < 0.8 nm) nucleation layers on an Si/SiO x substrate, which enabled the CVD growth of such ultrathin NCD films in two different and complementary microwave (MW) CVD systems: (i) focused MW plasma with an ellipsoidal cavity resonator and (ii) pulsed MW plasma with a linear antenna arrangement. Analytical ultracentrifuge, infrared and Raman spectroscopies, atomic force microscopy, and scanning electron microscopy are used for detailed characterization of the 2 nm H-DNDs and the nucleation layer as well as the ultrathin NCD films. We also demonstrate on/off switching of the SiV center PL in the NCD films thinner than 10 nm, which is achieved by changing their surface chemistry.

  4. Grating writing and growth at 325nm in non-hydrogenated silica fiber

    DEFF Research Database (Denmark)

    Town, Graham E; Yuan, Scott Wu; Stefani, Alessio

    We report on the writing and growth dynamics of Bragg gratings written in standard silica fiber using a 325nm He:Cd laser.......We report on the writing and growth dynamics of Bragg gratings written in standard silica fiber using a 325nm He:Cd laser....

  5. Sub-10-nm Graphene Nanoribbons with Tunable Surface Functionalities for Lithium-ion Batteries

    International Nuclear Information System (INIS)

    Li, Yan-Sheng; Ao, Xiang; Liao, Jia-Liang; Jiang, Jianjun; Wang, Chundong; Chiang, Wei-Hung

    2017-01-01

    Highlights: •A green and scalable method to produce sub-10-nm GNR is present. •The surface functionality of sub-10-nm GNR is critical for the LIB properties. •The sub-10-nm GNR showed superior LIB capacity of 490.4 mAh g −1 after 100 cycles. -- Abstract: A systematic study to reveal the relationship between the surface oxygen-containing functionalities of sub-10-nm GNRs and their electrochemical properties for lithium-ion batteries has been presented. Sub-10-nm GNRs with controlled oxygen-containing groups were synthesized by a green and scalable intercalation-assisted unzipping SWCNTs. Detailed materials characterizations including TEM, XRD, Raman and XPS indicate that KNO 3 could be an effective intercalation agent to facilitate the SWCNT unzipping by reducing the strong Van der Waals force attraction of bundled SWCNT. The levels of surface functionalities of sub-10-nm GNR were tuned by carefully controlling the KMnO 4 concentration during the unzipping process. The electrochemical analysis suggests that the as-produced sub-10-nm GNR with 31.4 atomic percent (atom %) oxygen-containing functional groups showed the highest capacity of 490.4 mAh g −1 after 100 cycles. This work proposed that sub-10-nm GNRs with appropriate oxygen-functional groups can be a promising electrode material for high performance lithium-ion batteries.

  6. Nearest-IR superluminescent diodes with a 100-nm spectral width

    Energy Technology Data Exchange (ETDEWEB)

    Il' chenko, S N; Ladugin, M A; Marmalyuk, Aleksandr A; Yakubovich, S D

    2012-11-30

    This paper presents an experimental study of quantum well superluminescent diodes with an extremely thin (InGa)As active layer. Under cw injection, the output power of such diodes is several milliwatts, with a centre wavelength of 830 nm and emission bandwidth of about 100 nm. (letters)

  7. EVALUATION OF THE PROGNOSTIC VALUE OF nm23 GENE EXPRESSION IN BREAST CANCER

    Institute of Scientific and Technical Information of China (English)

    刘红; 毛慧生; 傅西林; 方志沂; 冯玉梅; 范宇; 李树玲

    2002-01-01

    Objective: To investigate the expression of nm23 gene and evaluate its prognostic value in breast cancer. Methods: nm23 expressions were detected in 101 breast cancer patients (group 1) by immunohistochemistry. RT-PCR and immunohistochemistry were used to measure expressions of nm23 gene in another 68 patients with breast cancer (group 2). Results: nm23 gene expression in group 1 was inversely associated with distant metastasis and lymph node metastasis (P<0.05). In 44 patients with negative lymph node, 9 cases progressed to distant metastasis, 7 of them (77.8%) showed low expression of nm23 gene (P<0.05). In 57 patients with positive lymph node, 24 our of 29 patients who had no distant metastasis (82.8%) expressed nm23 gene at high level (P<0.05). Meanwhile, there were 6 patients with distant metastasis in the group 2, all of thenm expressed nm23 gene mRNA at low level. Conclusion: The results showed that nm23 gene might play an independent role in predicting prognosis of breast cancer.

  8. Evaluation of 405 nm monochromatic light for inactivation of tulane virus on blueberry surfaces

    Science.gov (United States)

    The aim of this study was to evaluate the potential of 405 nm light as an intervention for virus contaminated blueberries. Tulane virus-contaminated-blueberries were treated with 4.2 mW/sq cm of 405 nm light for 5 to 30 min. To mitigate thermal heating due to the intense light, a dry ice-chilled ni...

  9. High-reflectance La/B-based multilayer mirror for 6.x  nm wavelength

    NARCIS (Netherlands)

    Kuznetsov, Dmitry; Yakshin, Andrey; Sturm, Jacobus Marinus; van de Kruijs, Robbert Wilhelmus Elisabeth; Louis, Eric; Bijkerk, Frederik

    2015-01-01

    We report a hybrid thin-film deposition procedure to significantly enhance the reflectivity of La/B-based multilayer structures. This is of relevance for applications of multilayer optics at 6.7-nm wavelength and beyond. Such multilayers showed a reflectance of 64.1% at 6.65 nm measured at

  10. Inhibition of enteric pathogens using integrated high intensity 405 nm LED on the surface of almonds

    Science.gov (United States)

    The disinfecting properties of 405 nm light were investigated against Escherichia coli O157:H7, Salmonella, and their non-pathogenic surrogates inoculated onto the surface of almonds. High intensity monochromatic light was generated from an array of narrow-band 405 nm light emitting diodes (LED). Al...

  11. High-power frequency-stabilized laser for laser cooling of metastable helium at 389 nm

    NARCIS (Netherlands)

    Koelemeij, J.C.J.; Hogervorst, W.; Vassen, W.

    2005-01-01

    A high-power, frequency-stabilized laser for cooling of metastable helium atoms using the 2 S13 →3 P23 transition at 389 nm has been developed. The 389 nm light is generated by frequency doubling of a titanium:sapphire laser in an external enhancement cavity containing a lithium-triborate nonlinear

  12. Region 9 NPL Sites (Superfund Sites 2013)

    Science.gov (United States)

    NPL site POINT locations for the US EPA Region 9. NPL (National Priorities List) sites are hazardous waste sites that are eligible for extensive long-term cleanup under the Superfund program. Eligibility is determined by a scoring method called Hazard Ranking System. Sites with high scores are listed on the NPL. The majority of the locations are derived from polygon centroids of digitized site boundaries. The remaining locations were generated from address geocoding and digitizing. Area covered by this data set include Arizona, California, Nevada, Hawaii, Guam, American Samoa, Northern Marianas and Trust Territories. Attributes include NPL status codes, NPL industry type codes and environmental indicators. Related table, NPL_Contaminants contains information about contaminated media types and chemicals. This is a one-to-many relate and can be related to the feature class using the relationship classes under the Feature Data Set ENVIRO_CONTAMINANT.

  13. A high power, continuous-wave, single-frequency fiber amplifier at 1091 nm and frequency doubling to 545.5 nm

    International Nuclear Information System (INIS)

    Stappel, M; Steinborn, R; Kolbe, D; Walz, J

    2013-01-01

    We present a high power single-frequency ytterbium fiber amplifier system with an output power of 30 W at 1091 nm. The amplifier system consists of two stages, a preamplifier stage in which amplified spontaneous emission is efficiently suppressed (>40 dB) and a high power amplifier with an efficiency of 52%. Two different approaches to frequency doubling are compared. We achieve 8.6 W at 545.5 nm by single-pass frequency doubling in a MgO-doped periodically poled stoichiometric LiTaO 3 crystal and up to 19.3 W at 545.5 nm by frequency doubling with a lithium-triborate crystal in an external enhancement cavity. (paper)

  14. Low-noise low-jitter 32-pixels CMOS single-photon avalanche diodes array for single-photon counting from 300 nm to 900 nm

    Energy Technology Data Exchange (ETDEWEB)

    Scarcella, Carmelo; Tosi, Alberto, E-mail: alberto.tosi@polimi.it; Villa, Federica; Tisa, Simone; Zappa, Franco [Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Piazza Leonardo da Vinci 32, I-20133 Milano (Italy)

    2013-12-15

    We developed a single-photon counting multichannel detection system, based on a monolithic linear array of 32 CMOS SPADs (Complementary Metal-Oxide-Semiconductor Single-Photon Avalanche Diodes). All channels achieve a timing resolution of 100 ps (full-width at half maximum) and a photon detection efficiency of 50% at 400 nm. Dark count rate is very low even at room temperature, being about 125 counts/s for 50 μm active area diameter SPADs. Detection performance and microelectronic compactness of this CMOS SPAD array make it the best candidate for ultra-compact time-resolved spectrometers with single-photon sensitivity from 300 nm to 900 nm.

  15. In situ growth monitoring of AlGaN/GaN distributed Bragg reflectors at 530 nm using a 633 nm laser

    Energy Technology Data Exchange (ETDEWEB)

    Wen Feng; Huang Lirong; Jiang Bo; Tong Liangzhu; Xu Wei; Liu Deming, E-mail: hlr5649@163.co [Wuhan National Laboratory for Optoelectronics, College of Opto-Electronics Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2010-09-15

    The metal-organic chemical vapor deposition (MOCVD) growth of AlGaN/GaN distributed Bragg reflectors (DBR) with a reflection peak at 530 nm was in situ monitored using 633 nm laser reflectometry. Evolutions of in situ reflected reflectivity for different kinds of AlGaN/GaN DBR were simulated by the classical transfer matrix method. Two DBR samples, which have the same parameters as the simulated structures, were grown by MOCVD. The simulated and experimental results show that it is possible to evaluate the DBR parameters from the envelope shape of the in situ reflectivity spectrum. With the help of the 633 nm laser reflectometry, a DBR light emitting diode (LED) was grown. The room temperature photoluminescence spectra show that the reflection peak of the DBR in the LED is within the design region. (semiconductor devices)

  16. Laser ablation of ceramic Al{sub 2}O{sub 3} at 193 nm and 248 nm: The importance of single-photon ionization processes

    Energy Technology Data Exchange (ETDEWEB)

    Pelaez, R. J.; Afonso, C. N. [Laser Processing Group, Instituto de Optica, CSIC, Serrano 121, Madrid 28006 (Spain); Bator, M.; Lippert, T. [General Energy Research Department, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland)

    2013-06-14

    The aim of this work is to demonstrate that single-photon photoionization processes make a significant difference in the expansion and temperature of the plasma produced by laser ablation of ceramic Al{sub 2}O{sub 3} in vacuum as well as to show their consequences in the kinetic energy distribution of the species that eventually will impact on the film properties produced by pulsed laser deposition. This work compares results obtained by mass spectrometry and optical spectroscopy on the composition and features of the plasma produced by laser ablation at 193 nm and 248 nm, i.e., photon energies that are, respectively, above and below the ionization potential of Al, and for fluences between threshold for visible plasma and up to Almost-Equal-To 2 times higher. The results show that the ionic composition and excitation of the plasma as well as the ion kinetic energies are much higher at 193 nm than at 248 nm and, in the latter case, the population of excited ions is even negligible. The comparison of Maxwell-Boltzmann temperature, electron temperatures, and densities of the plasmas produced with the two laser wavelengths suggests that the expansion of the plasma produced at 248 nm is dominated by a single population. Instead, the one produced at 193 nm is consistent with the existence of two populations of cold and hot species, the latter associated to Al{sup +} ions that travel at the forefront and produced by single photon ionization as well as Al neutrals and double ionized ions produced by electron-ion impact. The results also show that the most energetic Al neutrals in the plasma produced at the two studied wavelengths are in the ground state.

  17. Laser ablation of ceramic Al2O3 at 193 nm and 248 nm: The importance of single-photon ionization processes

    Science.gov (United States)

    Peláez, R. J.; Afonso, C. N.; Bator, M.; Lippert, T.

    2013-06-01

    The aim of this work is to demonstrate that single-photon photoionization processes make a significant difference in the expansion and temperature of the plasma produced by laser ablation of ceramic Al2O3 in vacuum as well as to show their consequences in the kinetic energy distribution of the species that eventually will impact on the film properties produced by pulsed laser deposition. This work compares results obtained by mass spectrometry and optical spectroscopy on the composition and features of the plasma produced by laser ablation at 193 nm and 248 nm, i.e., photon energies that are, respectively, above and below the ionization potential of Al, and for fluences between threshold for visible plasma and up to ≈2 times higher. The results show that the ionic composition and excitation of the plasma as well as the ion kinetic energies are much higher at 193 nm than at 248 nm and, in the latter case, the population of excited ions is even negligible. The comparison of Maxwell-Boltzmann temperature, electron temperatures, and densities of the plasmas produced with the two laser wavelengths suggests that the expansion of the plasma produced at 248 nm is dominated by a single population. Instead, the one produced at 193 nm is consistent with the existence of two populations of cold and hot species, the latter associated to Al+ ions that travel at the forefront and produced by single photon ionization as well as Al neutrals and double ionized ions produced by electron-ion impact. The results also show that the most energetic Al neutrals in the plasma produced at the two studied wavelengths are in the ground state.

  18. Prospective study of the 532 nm laser (KTP) versus diode laser 980 nm in the resection of hyperplastic lesions of the oral cavity

    Science.gov (United States)

    Bargiela-Pérez, Patricia; González-Merchán, Jorge; Díaz-Sánchez, Rosa; Serrera-Figallo, Maria-Angeles; Volland, Gerd; Joergens, Martin; Gutiérrez-Pérez, Jose-Luis

    2018-01-01

    Background The aim of this study is to evaluate the resection of hyperplastic lesions on the buccal mucosa comparing the 532nm laser (KTP), versus diode 980nm laser, considering pain, scarring, inflammation and drug consumption that occurred postoperatively with each lasers. Material and Methods A prospective study of consecutive series of 20 patients in two groups that presents hyperplastic lesions on the buccal mucosa. The choice of the KTP laser or diode 980nm laser for the surgery was made randomly. The power used was 1.5W in both groups in a continuous wave mode with a 320 μm optical fiber. Parameters of pain, scarring, inflammation and consumption of drugs were recorded by a Numerical Rating Scale and evaluated postoperatively. These recordings were made the day of the surgery, 24 hours after, 14 and 28 days after. Results Pain and inflammation was light - moderate. The consumption of paracetamol was somewhat higher in the diode 980nm laser versus the KTP laser after 24 hours, although data was not statistically significant; significant differences were found after 28 days in regards to pain (p = 0.023) and inflammation (p = 0.023), but always in the absence parameter so we find no pain in both lasers. Scarring in the two types of laser showed no differences along the visits, with not detected scar retractable. Conclusions Although there is a slight histological difference regarding the KTP laser in the oral soft tissues for clinical use, both wavelengths are very suitable for excision of oral fibroma. Key words:Laser surgery, Laser therapy, oral surgery, soft tissue, 980 nm diode laser, 532 nm KTP laser. PMID:29274158

  19. Diode-pumped cw Nd:YAG three-level laser at 869 nm.

    Science.gov (United States)

    Lü, Yanfei; Xia, Jing; Cheng, Weibo; Chen, Jifeng; Ning, Guobin; Liang, Zuoliang

    2010-11-01

    We report for the first time (to our knowledge) a diode-pumped Nd:YAG laser emitting at 869 nm based on the (4)F(3/2)-(4)I(9/2) transition, generally used for a 946 nm emission. Power of 453 mW at 869 nm has been achieved in cw operation with a fiber-coupled laser diode emitting 35.4 W at 809 nm. Intracavity second-harmonic generation in the cw mode has also been demonstrated with power of 118 mW at 435 nm by using a BiB(3)O(6) nonlinear crystal. In our experiment, we used a LiNbO(3) crystal lens to complement the thermal lens of the laser rod, and we obtained good beam quality and high output power stability.

  20. Building blocks for future detectors: Silicon test masses and 1550 nm laser light

    International Nuclear Information System (INIS)

    Schnabel, R; Britzger, M; Burmeister, O; Danzmann, K; Duck, J; Eberle, T; Friedrich, D; Luck, H; Mehmet, M; Steinlechner, S; Willke, B; Brueckner, F; Nawrodt, R

    2010-01-01

    Current interferometric gravitational wave detectors use the combination of quasi-monochromatic, continuous-wave laser light at 1064 nm and fused silica test masses at room temperature. Detectors of the third generation, such as the Einstein-Telescope, will involve a considerable sensitivity increase. The combination of 1550 nm laser radiation and crystalline silicon test masses at low temperatures might be important ingredients in order to achieve the sensitivity goal. Here we compare some properties of the fused silica and silicon test mass materials relevant for decreasing the thermal noise in future detectors as well as the recent technology achievements in the preparation of laser radiation at 1064 nm and 1550 nm relevant for decreasing the quantum noise. We conclude that silicon test masses and 1550 nm laser light have the potential to form the future building blocks of gravitational wave detection.

  1. Repair of 313-nm induced lesions and photoprotection in yeast Candida guilliermondii

    International Nuclear Information System (INIS)

    Fraikin, G.Y.; Pospelov, M.E.; Rubin, L.B.

    1977-01-01

    The present communication is concerned with the effects of near-UV radiation (300-380 nm) on yeast Candida guilliermondii. It was found that certain doses of 313 nm irradiation caused inactivation of the yeast which was exhibited in a way different from the lethal action of far-UV radiation. It was also found that the cells inactivated by 313 nm are capable of recovering vitality, if incubated for some time in a non-nutrient medium. The yeast inactivated by far-UV radiation also proved to be capable of recovering, though to a lesser degree. Both 334 nm radiation and non-lethal doses at 313 nm induced the photoprotective effect against far-UV damage. The effect was exhibited if there was a certain time interval (2-4 h) between the exposures to photoprotective light and subsequent far-UV radiation. Within this time interval the extent of photoprotection was dependent on temperature. (author)

  2. [3]tetrahydrotrazodone binding. Association with serotonin binding sites

    International Nuclear Information System (INIS)

    Kendall, D.A.; Taylor, D.P.; Enna, S.J.

    1983-01-01

    High (17 nM) and low (603 nM) affinity binding sites for [ 3 ]tetrahydrotrazodone ([ 3 ] THT), a biologically active analogue of trazodone, have been identified in rat brain membranes. The substrate specificity, concentration, and subcellular and regional distributions of these sites suggest that they may represent a component of the serotonin transmitter system. Pharmacological analysis of [ 3 ]THT binding, coupled with brain lesion and drug treatment experiments, revealed that, unlike other antidepressants, [ 3 ] THT does not attach to either a biogenic amine transporter or serotonin binding sites. Rather, it would appear that [ 3 ]THT may be an antagonist ligand for the serotonin binding site. This probe may prove of value in defining the mechanism of action of trazodone and in further characterizing serotonin receptors

  3. Methodology of site studies

    International Nuclear Information System (INIS)

    Caries, J.C.; Hugon, J.; Grauby, A.

    1980-01-01

    This methodology consists in an essentially dynamic, estimated and follow-up analysis of the impact of discharges on all the environment compartments, whether natural or not, that play a part in the protection of man and his environment. It applies at two levels, to wit: the choice of site, or the detailed study of the site selected. Two examples of its application will be developed, namely: at the choice of site level in the case of marine sites, and of the detailed study level of the chosen site in that of a riverside site [fr

  4. Aerosol extinction profiles at 525 nm and 1020 nm derived from ACE imager data: comparisons with GOMOS, SAGE II, SAGE III, POAM III, and OSIRIS

    Directory of Open Access Journals (Sweden)

    F. Vanhellemont

    2008-04-01

    Full Text Available The Canadian ACE (Atmospheric Chemistry Experiment mission is dedicated to the retrieval of a large number of atmospheric trace gas species using the solar occultation technique in the infrared and UV/visible spectral domain. However, two additional solar disk imagers (at 525 nm and 1020 nm were added for a number of reasons, including the retrieval of aerosol and cloud products. In this paper, we present first comparison results for these imager aerosol/cloud optical extinction coefficient profiles, with the ones derived from measurements performed by 3 solar occultation instruments (SAGE II, SAGE III, POAM III, one stellar occultation instrument (GOMOS and one limb sounder (OSIRIS. The results indicate that the ACE imager profiles are of good quality in the upper troposphere/lower stratosphere, although the aerosol extinction for the visible channel at 525 nm contains a significant negative bias at higher altitudes, while the relative differences indicate that ACE profiles are almost always too high at 1020 nm. Both problems are probably related to ACE imager instrumental issues.

  5. Power and efficiency scaling of diode pumped Cr:LiSAF lasers: 770-1110 nm tuning range and frequency doubling to 387-463 nm.

    Science.gov (United States)

    Demirbas, Umit; Baali, Ilyes

    2015-10-15

    We report significant average power and efficiency scaling of diode-pumped Cr:LiSAF lasers in continuous-wave (cw), cw frequency-doubled, and mode-locked regimes. Four single-emitter broad-area laser diodes around 660 nm were used as the pump source, which provided a total pump power of 7.2 W. To minimize thermal effects, a 20 mm long Cr:LiSAF sample with a relatively low Cr-concentration (0.8%) was used as the gain medium. In cw laser experiments, 2.4 W of output power, a slope efficiency of 50%, and a tuning range covering the 770-1110 nm region were achieved. Intracavity frequency doubling with beta-barium borate (BBO) crystals generated up to 1160 mW of blue power and a record tuning range in the 387-463 nm region. When mode locked with a saturable absorber mirror, the laser produced 195 fs pulses with 580 mW of average power around 820 nm at a 100.3 MHz repetition rate. The optical-to-optical conversion efficiency of the system was 33% in cw, 16% in cw frequency-doubled, and 8% in cw mode-locked regimes.

  6. 1018 nm Yb-doped high-power fiber laser pumped by broadband pump sources around 915 nm with output power above 100 W

    DEFF Research Database (Denmark)

    Midilli, Yakup; Efunbajo, Oyewole Benjamin; Şimşek, Bartu

    2017-01-01

    laser were also addressed in this study. Finally, we have tested this system for high power experimentation and obtained 67% maximum optical-to-optical efficiency at an approximately 110 W output power level. To the best of our knowledge, this is the first 1018 nm ytterbium-doped all-fiber laser pumped...

  7. Results from a new 193nm die-to-database reticle inspection platform

    Science.gov (United States)

    Broadbent, William H.; Alles, David S.; Giusti, Michael T.; Kvamme, Damon F.; Shi, Rui-fang; Sousa, Weston L.; Walsh, Robert; Xiong, Yalin

    2010-05-01

    A new 193nm wavelength high resolution reticle defect inspection platform has been developed for both die-to-database and die-to-die inspection modes. In its initial configuration, this innovative platform has been designed to meet the reticle qualification requirements of the IC industry for the 22nm logic and 3xhp memory generations (and shrinks) with planned extensions to the next generation. The 22nm/3xhp IC generation includes advanced 193nm optical lithography using conventional RET, advanced computational lithography, and double patterning. Further, EUV pilot line lithography is beginning. This advanced 193nm inspection platform has world-class performance and the capability to meet these diverse needs in optical and EUV lithography. The architecture of the new 193nm inspection platform is described. Die-to-database inspection results are shown on a variety of reticles from industry sources; these reticles include standard programmed defect test reticles, as well as advanced optical and EUV product and product-like reticles. Results show high sensitivity and low false and nuisance detections on complex optical reticle designs and small feature size EUV reticles. A direct comparison with the existing industry standard 257nm wavelength inspection system shows measurable sensitivity improvement for small feature sizes

  8. Compact gain saturated plasma based X-ray lasers down to 6.9nm

    Science.gov (United States)

    Rocca, Jorge; Wang, Y.; Wang, S.; Rockwood, A.; Berrill, M.; Shlyaptsev, V.

    2017-10-01

    Plasma based soft x-ray amplifiers allow many experiments requiring bright, high energy soft x-ray laser pulses to be conducted in compact facilities. We have extended the wavelength of compact gain saturated x-ray lasers to 6.89 nm in a Ni-like Gd plasma generated by a Ti:Sa laser. Gain saturated laser operation was also obtained at 7.36 nm in Ni-like Sm. Isolectronic scaling and optimization of laser pre-pulse duration allowed us to also observe strong lasing at 6.6 nm and 6.1 nm in Ni-like Tb, and amplification at 6.4 nm and 5.89 nm in Ni-like Dy. The results were obtained by transient laser heating of solid targets with traveling wave excitation at progressively increased gracing incidence angles. We show that the optimum pump angle of incidence for collisional Ni-like lasers increases linearly with atomic number from Z =42 to Z =66, reaching 43 degrees for Ni-like Dy, in good agreement with hydrodynamic/atomic physics simulations. These results will enable single-shot nano-scale imaging and other application of sub-7 nm lasers to be performed at compact facilities. Work supported by Grant DE-FG02-4ER15592 of the Department of Energy, Office of Science, and by the National Science Foundation Grant ECCS 1509925.

  9. Comparative analysis of the effect of the GaAlAs laser irradiation in 780 nm and 660 nm in the hypersensitive dentin; Analise comparativa do efeito da irradiacao do laser de GaAlAs em 780 nm e 660 nm na hipersensibilidade dentinaria

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Sun Chien

    2003-07-01

    This study was to evaluate and compare the effects of the low intensity in laser radiation among GaAlAs 780 nm and GaAlAs 660 nm. The main proposal is to verify if there is any difference of the effects or results in low intensity laser application treatment of hypersensitive dentin, keeping the same parameters, only differing in wavelength. The samples were distributed in two groups. Group A 90 cases, treated with GaAlAs 780 nm and group B irradiated with GaAlAs 660 nm with a total of 76 cases analyzed. The results of application with GaAlAs 660 nm and GaAlAs 780 nm do not differ statistically. Which means using any one of the irradiation gives the same results. However can be noted that the response of reduction of hypersensitivity is faster with the radiation of GaAlAs 780 nm, but the results after three applications is the same for both types of radiation. (author)

  10. Preparation of sub 3 nm copper nanoparticles by microwave irradiation in the presence of triethylene tetramin

    Science.gov (United States)

    Tseng, Po-Hao; Wang, Yen-Zen; Hsieh, Tar-Hwa; Ho, Ko-Shan; Tsai, Cheng-Hsien; Chen, Kuan-Ting

    2018-02-01

    The preparation of sub 3 nm copper nanoparticles (CuNPs) in ethylene glycol (EG) using triethylene tetramine (TETA) as chelating and reducing agents via a rapid microwave (MW) irradiation is reported. The sub 3 nm CuNPs after MW irradiation are clearly seen from the electronic micrographs. The firm chelation of Cu2+ by TETA is illustrated by the dark blue color of Cu2+/TETA/EG solution and the redox reaction is confirmed by the appearance of red color of the mixtures. The optimal mole ratio of TETA/Cu 2+ is found to be 2.5/1 for preparing sub 3 nm CuNPs under the MW irradiation, operated at 800 W for 1 min. The plasmonic absorption λ max demonstrated in UV-vis spectra are found to close to 200 nm for sub 3 nm CuNPs, comparing to 500 ˜ 600 nm for regular, larger CuNPs. The extremely low Tm around 30 °C and the fusion/recrystallization sequence of sub 3 nm CuNPs can be directly measured by their differential scanning calorimetry thermograms.

  11. Mapping the Use of Engineered NM in Quebec's Industries and Research Laboratories

    International Nuclear Information System (INIS)

    Ostiguy, Claude; Emond, Claude; Dossa, Inès; Plavski, Anton; Malki, Yasmina; Boily, Chantale; Roughley, David; Endo, Charles-Anica

    2013-01-01

    Engineered NanoMaterials (NM) offer an opportunity to develop a wide variety of new products with unique properties but many studies have shown potential OHS risks specific to NM. Addressing these risks requires knowledge about release of NM into the workplaces. This research aimed to map the state of nanotechnology OHS practices in Quebec through a questionnaire following a first contact by telephone when possible and by compiling the type and volumes of NM used as well as gathering information related to the working conditions and OHS aspects. This survey was conducted among 1310 Quebec industries and 653 researchers working in different specialties potentially involved in the development/production/distribution/integration of NM and use of NM containing products. Overall, 90 questionnaires, including 51 from the industries, were completed. These showed that NM are mainly used into the powder form, in many different sectors and deserve a wide range of markets. The prevention measures implemented vary widely from a workplace to another but about one third of the participants report that they have implemented NP adapted prevention measures but they remain worried on some specific operations. More than 50% of the participants request more information about the safe laboratory/plant design, toxicity, regulation, good work practices and prevention measures, efficiency of personal protective equipment and environmental impacts.

  12. Mapping the Use of Engineered NM in Quebec's Industries and Research Laboratories

    Science.gov (United States)

    Ostiguy, Claude; Emond, Claude; Dossa, Inès; Malki, Yasmina; Boily, Chantale; Roughley, David; Plavski, Anton; Endo, Charles-Anica

    2013-04-01

    Engineered NanoMaterials (NM) offer an opportunity to develop a wide variety of new products with unique properties but many studies have shown potential OHS risks specific to NM. Addressing these risks requires knowledge about release of NM into the workplaces. This research aimed to map the state of nanotechnology OHS practices in Quebec through a questionnaire following a first contact by telephone when possible and by compiling the type and volumes of NM used as well as gathering information related to the working conditions and OHS aspects. This survey was conducted among 1310 Quebec industries and 653 researchers working in different specialties potentially involved in the development/production/distribution/integration of NM and use of NM containing products. Overall, 90 questionnaires, including 51 from the industries, were completed. These showed that NM are mainly used into the powder form, in many different sectors and deserve a wide range of markets. The prevention measures implemented vary widely from a workplace to another but about one third of the participants report that they have implemented NP adapted prevention measures but they remain worried on some specific operations. More than 50% of the participants request more information about the safe laboratory/plant design, toxicity, regulation, good work practices and prevention measures, efficiency of personal protective equipment and environmental impacts.

  13. Synthesis and characterization of metastable, 20 nm-sized Pna21-LiCoPO4 nanospheres

    International Nuclear Information System (INIS)

    Ludwig, Jennifer; Nordlund, Dennis; Doeff, Marca M.; Nilges, Tom

    2017-01-01

    The majority of research activities on LiCoPO 4 are focused on the phospho-olivine (space group Pnma), which is a promising high-voltage cathode material for Li-ion batteries. In contrast, comparably little is known about its metastable Pna2 1 modification. Herein, we present a comprehensive study on the structure–property relationships of 15–20 nm Pna2 1 -LiCoPO 4 nanospheres prepared by a simple microwave-assisted solvothermal process. Unlike previous reports, the results indicate that the compound is non-stoichiometric and shows cation-mixing with Co ions on the Li sites, which provides an explanation for the poor electrochemical performance. Co L 2,3 -edge X-ray absorption spectroscopic data confirm the local tetrahedral symmetry of Co 2+ . Comprehensive studies on the thermal stability using thermogravimetric analysis, differential scanning calorimetry, and in situ powder X-ray diffraction show an exothermic phase transition to olivine Pnma-LiCoPO 4 at 527 °C. The influence of the atmosphere and the particle size on the thermal stability is also investigated. - Graphical abstract: Blue nano-sized Pna2 1 -LiCoPO 4, featuring tetrahedrally-coordinated Co 2+ , was synthesized in a rapid one-step microwave-assisted solvothermal process. The phase relation between this metastable and the stable polymorph was analyzed and electrochemical properties are discussed. - Highlights: • Preparation of uniform 15–20 nm nanospheres of metastable Pna2 1 -LiCoPO 4 polymorph. • Structure redetermination shows cation-mixing (Co blocking Li sites). • In situ investigation of phase transformation to olivine Pnma-LiCoPO 4 at 527 °C. • Pna2 1 -LiCoPO 4 reemerges as a stable high-temperature phase above 800 °C. • X-ray absorption spectroscopy confirms local tetrahedral symmetry (T d Co 2+ ).

  14. Treatment of tattoos with a 755-nm Q-switched alexandrite laser and novel 1064 nm and 532 nm Nd:YAG laser handpieces pumped by the alexandrite treatment beam.

    Science.gov (United States)

    Bernstein, Eric F; Bhawalkar, Jay; Clifford, Joan; Hsia, James

    2010-11-01

    Multi-colored and even black tattoos often require more than one wavelength to remove the target pigment. The authors report here a novel alexandrite laser with two Nd:YAG laser handpieces pumped by the alexandrite treatment beam enabling the delivery of three wavelengths from a single device. To describe and evaluate the effectiveness of a novel Q-switched laser-pumped laser for treating tattoos. Twenty tattoos in 14 subjects were treated at four-week intervals using a combination of available wavelengths (532, 755 and 1064 nm) as determined by the treating physician. Digital cross-polarized photographs were taken before treatment and two months following the fourth and final treatment. Photographs were evaluated by three physician observers blinded as to the treatment condition and rated for clearance by the following scale: 1 = > 95 percent, 2 = 76-95 percent, 3 = 51-75 percent, 4 = 26-50 percent and 5 = 0-25 percent clearance. The average clearance score was 3.1, in the 51-75 percent range, two months following four treatments. No scarring, hyper- or hypopigmentation was noted on post-treatment photographs or by the treating physician. The alexandrite and alexandrite-pumped 532 nm and 1064 nm Q-switched lasers are effective for removing decorative tattoos, and represents the first commercial laser with laser-pumped, laser handpieces.

  15. Exploration of BEOL line-space patterning options at 12 nm half-pitch and below

    Science.gov (United States)

    Decoster, S.; Lazzarino, F.; Petersen Barbosa Lima, L.; Li, W.; Versluijs, J.; Halder, S.; Mallik, A.; Murdoch, G.

    2018-03-01

    While the semiconductor industry is almost ready for high-volume manufacturing of the 7 nm technology node, research centers are defining and troubleshooting the patterning options for the 5 nm technology node (N5) and below. The target dimension for imec's N5 BEOL applications is 20-24 nm Metal Pitch (MP), which requires Self-Aligned multiple (Double/Quadruple/Octuple) Patterning approaches (SAxP) in combination with EUV or immersion lithography at 193 nm. There are numerous technical challenges to enable gratings at the hard mask level such as good uniformity across wafer, low line edge/width roughness (LER/LWR), large process window, and all of this at low cost. An even greater challenge is to transfer these gratings into the dielectric material at such critical dimensions, where increased line edge roughness, line wiggling and even pattern collapse can be expected for materials with small mechanical stability such as highly porous low-k dielectrics. In this work we first compare three different patterning options for 12 nm half-pitch gratings at the hard mask level: EUV-based SADP and 193i-based SAQP and SAOP. This comparison will be based on process window, line edge/width roughness and cost. Next, the transfer of 12 nm line/space gratings in the dielectric material is discussed and presented. The LER of the dielectric lines is investigated as a function of the dielectric material, the trench depth, and the stress in the sacrificial hard mask. Finally, we elaborate on the different options to enable scaling down from 24 nm MP to 16 nm MP, and demonstrate 8 nm line/space gratings with 193i-based SAOP.

  16. Efficiency of soft tissue incision with a novel 445-nm semiconductor laser.

    Science.gov (United States)

    Braun, Andreas; Kettner, Moritz; Berthold, Michael; Wenzler, Johannes-Simon; Heymann, Paul Günther Baptist; Frankenberger, Roland

    2018-01-01

    Using a 445-nm semiconductor laser for tissue incision, an effective cut is expected due to the special absorption properties of blue laser light in soft tissues. The aim of the present study was the histological evaluation of tissue samples after incision with a 445-nm diode laser. Forty soft tissue specimens were obtained from pork oral mucosa and mounted on a motorized linear translation stage. The handpiece of a high-frequency surgery device, a 970-nm semiconductor laser, and a 445-nm semiconductor laser were connected to the slide, allowing a constant linear movement (2 mm/s) and the same distance of the working tip to the soft tissue's surface. Four incisions were made each: (I) 970-nm laser with conditioned fiber tip, contact mode at 3-W cw; (II-III): 445-nm laser with non-conditioned fiber tip, contact mode at 2-W cw, and non-contact mode (1 mm) at 2 W; and (IV): high-frequency surgery device with straight working tip, 90° angulation, contact mode at 50 W. Histological analysis was performed after H&E staining of the embedded specimens at 35-fold magnification. The comparison of the incision depths showed a significant difference depending on the laser wavelength and the selected laser parameters. The highest incision depth was achieved with the 445-nm laser contact mode (median depth 0.61 mm, min 0.26, max 1.17, interquartile range 0.58) (p laser, a higher cutting efficiency can be expected when compared with a 970-nm diode laser and high-frequency surgery. Even the 445-nm laser application in non-contact mode shows clinically acceptable incision depths without signs of extensive soft tissue denaturation.

  17. NM23 protein expression in colorectal carcinoma using TMA (tissue microarray: association with metastases and survival

    Directory of Open Access Journals (Sweden)

    Levindo Alves de Oliveira

    2010-12-01

    Full Text Available CONTEXT: NM23, a metastasis suppressor gene, may be associated with prognosis in patients with colorectal carcinoma. OBJECTIVE: To analyze NM23 expression and its association with the presence of lymph node and liver metastases and survival in patients operated on for colorectal carcinoma. METHODS: One hundred thirty patients operated on for colorectal carcinoma were investigated. Tissue microarray blocks containing neoplastic tissue and tumor-adjacent non-neoplastic mucosa were obtained and analyzed by immunohistochemical staining using a monoclonal anti-NM23 antibody. Immunohistochemical expression was assessed using a semiquantitative scoring method, counting the percentage of stained cells. The results were compared regarding morphological and histological characteristics of the colorectal carcinoma, presence of lymph node and liver metastases, tumor staging, and patient survival. Statistical analysis was performed using the Mann-Whitney test, the Kruskal-Wallis test and Fisher's exact test. Survival analysis was performed using the Kaplan-Meier method and the log-rank test. RESULTS: NM23 expression was higher in colorectal carcinoma tissue than in adjacent non-neoplastic mucosa (P<0.0001. NM23 protein expression did not correlate with degree of cell differentiation (P = 0.57, vascular invasion (P = 0.85, lymphatic invasion (P = 0.41, perineural infiltration (P = 0.46, staging (P = 0.19, lymph node metastases (P = 0.08, or liver metastases (P = 0.59. Disease-free survival showed significant association (P = 0.01 with the intensity of NM23 protein immunohistochemical expression in colorectal carcinoma tissue, whereas overall survival showed no association with NM23 protein expression (P = 0.13. CONCLUSIONS: NM23 protein expression was higher in neoplastic colorectal carcinoma tissue than in adjacent non-neoplastic mucosa, showing no correlation with morphological aspects, presence of lymph node or liver metastases, colorectal carcinoma

  18. Magnetic rotational hysteresis study on spherical 85-160 nm Fe3O4 particles

    Science.gov (United States)

    Schmidbauer, E.

    1988-05-01

    Rotational hysteresis losses Wr were determined as a function of magnetic field H for dispensed spherical Fe3O4 particles of mean grain sizes 85 nm, 127 nm and 162 nm between 78 K and 294 K. The observed Wr-H curves are compared with theoretical curves for single domain particles. The analysed particles reveal centers of high magnetic anisotropy. Such centers can be of importance during the generation of a thermoremanent magnetization, as they may be the origin of enhanced magnetic stability.

  19. Semiconductor optical amplifiers for the 1000-1100-nm spectral range

    International Nuclear Information System (INIS)

    Lobintsov, A A; Shramenko, M V; Yakubovich, S D

    2008-01-01

    Two types of semiconductor optical amplifiers (SOAs) based on a double-layer quantum-well (InGa)As/(GaAl)As/GaAs heterostructure are investigated. The optical gain of more than 30 dB and saturation output power of more than 30 mW are achived at 1060 nm in pigtailed SOA modules. These SOAs used as active elements of a tunable laser provide rapid continuous tuning within 85 nm and 45 nm at output powers of 0.5 mW and more than 30 mW, respectively. (active media, lasers, and amplifiers)

  20. Broadband superluminescent diodes and semiconductor optical amplifiers for the spectral range 750 - 800 nm

    International Nuclear Information System (INIS)

    Il'chenko, S N; Kostin, Yu O; Kukushkin, I A; Ladugin, M A; Lapin, P I; Lobintsov, A A; Marmalyuk, Aleksandr A; Yakubovich, S D

    2011-01-01

    We have studied superluminescent diodes (SLDs) and semiconductor optical amplifiers (SOAs) based on an (Al x Ga 1-x )As/GaAs single quantum well structure with an Al content x ∼ 0.1 in a 10-nm-thick active layer. Depending on the length of the active channel, the single-mode fibre coupled cw output power of the SLDs is 1 to 30 mW at a spectral width of about 50 nm. The width of the optical gain band in the active channel exceeds 40 nm. Preliminary operating life tests have demonstrated that the devices are sufficiently reliable. (lasers)

  1. National Environmental Policy Act (NEPA) compliance at Sandia National Laboratories/New Mexico (SNL/NM)

    International Nuclear Information System (INIS)

    Wolff, T.A.

    1998-08-01

    This report on National Environmental Policy Act (NEPA) compliance at Sandia National Laboratories/New Mexico (SNL/NM) chronicles past and current compliance activities and includes a recommended strategy that can be implemented for continued improvement. This report provides a list of important references. Attachment 1 contains the table of contents for SAND95-1648, National Environmental Policy Act (NEPA) Compliance Guide Sandia National Laboratories (Hansen, 1995). Attachment 2 contains a list of published environmental assessments (EAs) and environmental impact statements (EISs) prepared by SNL/NM. Attachment 3 contains abstracts of NEPA compliance papers authored by SNL/NM and its contractors

  2. EUV beam splitter for use in the wavelength region around 6 nm

    International Nuclear Information System (INIS)

    Takenaka, Hisataka; Ichimaru, Satoshi; Gullikson, E.M.

    2005-01-01

    Extreme ultraviolet (EUV) beam splitters for use at a wavelength of around 6 nm were fabricated. The designs were optimized for Cr/C multilayers and incident angles of 45 deg. and 80 deg. . Measurements revealed the reflectivity of a Cr/C beam splitter to be 3.3% and the transmittance to be 5.6% at a wavelength of 6.36 nm and an incident angle of 45 deg. . The reflectivity of a Cr/C beam splitter was 5.8% and the transmittance was 6.6% at a wavelength of 6.15 nm and an incident angle of 80 deg.

  3. National Environmental Policy Act (NEPA) compliance at Sandia National Laboratories/New Mexico (SNL/NM)

    Energy Technology Data Exchange (ETDEWEB)

    Wolff, T.A. [Sandia National Labs., Albuquerque, NM (United States). Community Involvement and Issues Management Dept.; Hansen, R.P. [Hansen Environmental Consultants, Englewood, CO (United States)

    1998-08-01

    This report on National Environmental Policy Act (NEPA) compliance at Sandia National Laboratories/New Mexico (SNL/NM) chronicles past and current compliance activities and includes a recommended strategy that can be implemented for continued improvement. This report provides a list of important references. Attachment 1 contains the table of contents for SAND95-1648, National Environmental Policy Act (NEPA) Compliance Guide Sandia National Laboratories (Hansen, 1995). Attachment 2 contains a list of published environmental assessments (EAs) and environmental impact statements (EISs) prepared by SNL/NM. Attachment 3 contains abstracts of NEPA compliance papers authored by SNL/NM and its contractors.

  4. Widely Tunable High-Power Tapered Diode Laser at 1060 nm

    DEFF Research Database (Denmark)

    Jensen, Ole Bjarlin; Sumpf, Bernd; Erbert, Götz

    2011-01-01

    We report a large tuning range from 1018 to 1093 nm from a InGaAs single quantum-well 1060-nm external cavity tapered diode laser. More than 2.5-W output power has been achieved. The tuning range is to our knowledge the widest obtained from a high-power InGaAs single quantum-well tapered laser...... operating around 1060 nm. The light emitted by the laser has a nearly diffraction limited beam quality and a narrow linewidth of less than 6 pm everywhere in the tuning range....

  5. NPL Site Locations

    Data.gov (United States)

    U.S. Environmental Protection Agency — The National Priorities List (NPL) is a list published by EPA of Superfund sites. A site must be added to this list before remediation can begin under Superfund. The...

  6. Site Area Boundaries

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset consists of site boundaries from multiple Superfund sites in U.S. EPA Region 8. These data were acquired from multiple sources at different times and...

  7. NPL Site Boundaries

    Data.gov (United States)

    U.S. Environmental Protection Agency — The National Priorities List (NPL) is a list published by EPA of Superfund sites. A site must be added to this list before remediation can begin under Superfund. The...

  8. Drupal 7 Multilingual Sites

    CERN Document Server

    Pol, Kristen

    2012-01-01

    A practical book with plenty of screenshots to guide you through the many features of multilingual Drupal. A demo ecommerce site is provided if you want to practice on a sample site, although you can apply the techniques learnt in the book directly to your site too. Any Drupal users who know the basics of building a Drupal site and are familiar with the Drupal UI, will benefit from this book. No previous knowledge of localization or internationalization is required.

  9. DEVELOPMENT AND TESTING OF PROCEDURES FOR CARRYING OUT EMERGENCY PHYSICAL INVENTORY TAKING AFTER DETECTING ANOMALY EVENTS CONCERNING NM SECURITY

    International Nuclear Information System (INIS)

    VALENTE, J.; FISHBONE, L.

    2003-01-01

    In the State Scientific Center of Russian Federation - Institute of Physics and Power Engineering (SSC RF-IPPE, Obninsk), which is under Minatom jurisdiction, the procedures for carrying out emergency physical inventory taking (EPIT) were developed and tested in cooperation with the Brookhaven National Laboratory (USA). Here the emergency physical inventory taking means the PIT, which is carried out in case of symptoms indicating a possibility of NM loss (theft). Such PIT often requires a verification of attributes and quantitative characteristics for all the NM items located in a specific Material Balance Area (MBA). In order to carry out the exercise, an MBA was selected where many thousands of NM items containing highly enriched uranium are used. Three clients of the computerized material accounting system (CMAS) are installed in this MBA. Labels with unique (within IPPE site) identification numbers in the form of digit combinations and an appropriate bar code have been applied on the NM items, containers and authorized locations. All the data to be checked during the EPIT are stored in the CMAS database. Five variants of anomalies initiating EPIT and requiring different types of activities on EPIT organization are considered. Automatic working places (AWP) were created on the basis of the client computers in order to carry out a large number of measurements within a reasonable time. In addition to a CMAS client computer, the main components of an AWP include a bar-code reader, an electronic scale and an enrichment meter with NaI--detector--the lMCA Inspector (manufactured by the Canberra Company). All these devices work together with a client computer in the on-line mode. Special computer code (Emergency Inventory Software-EIS) was developed. All the algorithms of interaction between the operator and the system, as well as algorithms of data exchange during the measurements and data comparison, are implemented in this software. Registration of detected

  10. Lower Energy Endovenous Laser Ablation of the Great Saphenous Vein with 980 nm Diode Laser in Continuous Mode

    International Nuclear Information System (INIS)

    Kim, Hyun S.; Nwankwo, Ikechi J.; Hong, Kelvin; McElgunn, Patrick S.J.

    2006-01-01

    Purpose. To assess clinical outcomes, complication rates, and unit energy applied using 980 nm diode endovenous laser treatment at 11 watts for symptomatic great saphenous vein (GSV) incompetence and reflux disease. Methods. Thirty-four consecutive ablation therapies with a 980 nm diode endovenous laser at 11 watts were studied. The diagnosis of GSV incompetence with reflux was made by clinical evaluation and duplex Doppler examinations. The treated GSVs had a mean diameter of 1.19 cm (range 0.5-2.2 cm). The patients were followed with clinical evaluation and color flow duplex studies up to 18.5 months (mean 12.19 months ± 4.18). Results. Using 980 nm diode endovenous laser ablation in continuous mode, 100% technical success was noted. The mean length of GSVs treated was 33.82 cm (range 15-45 cm). The mean energy applied during the treatment was 1,155.81 joules (J) ± 239.50 (range 545.40-1620 J) for a mean treatment duration of 90.77 sec ± 21.77. The average laser fiber withdrawal speed was 0.35 cm/sec ± 0.054. The mean energy applied per length of GSV was 35.16 J/cm ± 8.43. Energy fluence, calculated separately for each patient, averaged 9.82 J/cm 2 ± 4.97. At up to 18.5 months follow-up (mean 12.19 months), 0% recanalization was noted; 92% clinical improvement was achieved. There was no major complication. Minor complications included 1 patient with hematoma at the percutaneous venotomy site, 1 patient with thrombophlebitis on superficial tributary varices of the treated GSV, 24% ecchymoses, and 32% self-limiting hypersensitivity/tenderness/'pulling' sensation along the treatment area. One patient developed temporary paresthesia. Four endovenous laser ablation treatments (12%) were followed by adjunctive sclerotherapies for improved cosmetic results. Conclusion. Endovenous laser ablation treatment of GSV using a 980 nm diode laser at 11 watts in continuous mode appears safe and effective. Mean energy applied per treated GSV length of 35.16 J/cm or mean

  11. Nuclear waste repository siting

    International Nuclear Information System (INIS)

    Soloman, B.D.; Cameron, D.M.

    1987-01-01

    This paper discusses the geopolitics of nuclear waste disposal in the USA. Constitutional choice and social equity perspectives are used to argue for a more open and just repository siting program. The authors assert that every potential repository site inevitably contains geologic, environmental or other imperfections and that the political process is the correct one for determining sites selected

  12. Site Calibration report

    DEFF Research Database (Denmark)

    Yordanova, Ginka; Vesth, Allan

    The report describes site calibration measurements carried out on a site in Denmark. The measurements are carried out in accordance to Ref. [1]. The site calibration is carried out before a power performance measurement on a given turbine to clarify the influence from the terrain on the ratio...

  13. CCS site characterisation criteria

    Energy Technology Data Exchange (ETDEWEB)

    Bachu, S.; Hawkes, C.; Lawton, D.; Pooladi-Darvish, M.; Perkins, E.

    2009-12-15

    IEA GHG recently commissioned the Alberta Research Counil in Canada to conduct a review of storage site selection criteria and site characterisation methods in order to produce a synthesis report. This report reviews the literature on the subject on the site seleciton and characterisation since the publication of the IPCC Special Report on CCS, and provides a synthesis and classification of criteria. 161 refs.

  14. The SNL/NM Classified Waste Landfill Excavation: Lessons Learned Moving from Planning to Implementation

    International Nuclear Information System (INIS)

    Galloway, Robert B; Slavin, Paula

    1999-01-01

    The Sandia National Laboratories/New Mexico (SNL/NM) Environmental Restoration Project is halfway through excavating the Classified Waste Landfill in Technical Area II, a disposal area for weapon components for approximately 40 years. While the planning phase of any project is important, it is only a means of getting to the field implementation phase where reality quickly sinks in. Documents outlining the general processes are developed, heavy equipment, supply needs, requisite skills, and staffing levels are anticipated, and contingencies for waste management are put in place. However, the nature of landfill excavation dictates that even the most detailed plans will probably change. This project is proving that trying to account for undefined variables and predicting the total cost of landfill remediation is very difficult if the contents are not well known. In landfill excavation, contingency cannot be minimized. During development of the waste management plan, it was recognized that even the best forecasting could not formulate the perfect cradle-to-grave processes because waste streams are rarely definable before excavation begins. Typically, as excavation progresses and waste streams are generated, new characterization information allows further definition of disposal options which, in turn, modify the generation/management process. A general plan combined with close involvement of waste management personnel to resolve characterization and packaging questions during generation has worked very well. And, as expected, each new pit excavated creates new waste management challenges. The material excavated consists primarily of classified weapon assemblies and related components, so disposition must include demilitarization and sanitization. The demilitarization task at the start of the project was provided by an SNL/NM group that has since lost their funding and operational capability. This project is having to take on the task of disassembly, destruction, and

  15. Loss-Less planar waveguide 1:4 power splitter at 1550 nm

    DEFF Research Database (Denmark)

    Sckerl, Mads W.; Guldberg-Kjær, Søren Andreas; Laurent-Lund, Christian

    1999-01-01

    By a unique desposition/etching technique an erbuim-doped planar silica waveguide with intergrated splitter on a silicon substrate was produced and is demonstrated to show net gain at 1550 nm and good saturation and noise characteristics....

  16. Remote Sensing Reflectance at 667 nm , Aqua MODIS, NPP, 0.125 degrees, Gulf of Mexico

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — MODIS measures the remote sensing reflectance (Rrs) at 667nm. This can be used to view very high concentrations of phytoplankton in the very surface of the water.

  17. Photolysis of butenedial at 193, 248, 280, 308, 351, 400, and 450 nm

    Science.gov (United States)

    Tang, Yongxin; Zhu, Lei

    2005-06-01

    We have studied the photolysis of butenedial at 193, 248, 280, 308, 351, 400, and 450 nm by using laser photolysis combined with cavity ring-down spectroscopy. The HCO radical is a photodissociation product at 193 and 248 nm. The corresponding HCO quantum yields are 0.55 ± 0.07 and 0.12 ± 0.01, independent of butenedial pressure and nitrogen buffer gas pressure. Absorption cross-sections of butenedial are (6.88 ± 0.39) × 10 -18 and (3.62 ± 0.69) × 10 -19 cm 2 at 193 and 248 nm. The end-products from the photolysis of butenedial at 193, 248, 308, and 351 nm were measured by FTIR. Acrolein and 3H-furan-2-one were observed and their yields have been estimated.

  18. Wide-Field Imaging of Single-Nanoparticle Extinction with Sub-nm2 Sensitivity

    Science.gov (United States)

    Payne, Lukas M.; Langbein, Wolfgang; Borri, Paola

    2018-03-01

    We report on a highly sensitive wide-field imaging technique for quantitative measurement of the optical extinction cross section σext of single nanoparticles. The technique is simple and high speed, and it enables the simultaneous acquisition of hundreds of nanoparticles for statistical analysis. Using rapid referencing, fast acquisition, and a deconvolution analysis, a shot-noise-limited sensitivity down to 0.4 nm2 is achieved. Measurements on a set of individual gold nanoparticles of 5 nm diameter using this method yield σext=(10.0 ±3.1 ) nm2, which is consistent with theoretical expectations and well above the background fluctuations of 0.9 nm2 .

  19. Diode-pumped thin-disk Nd:GdVO4 laser at 893 nm

    International Nuclear Information System (INIS)

    Li, Y L; Fu, X H; Wang, A G

    2011-01-01

    We report for the first time a Nd:GdVO 4 laser operating in a continuous wave (CW) on the quasi-three-level laser at 893 nm, based on the 4 F 3/2 – 4 I 9/2 transition, generally used for a 912 nm emission. The use of a pump module with 16 passes through the crystal allowed the realization of a Nd:GdVO 4 thin-disk laser with 157 mW of CW output power at 893 nm. Moreover, intracavity second-harmonic generation (SHG) has also been achieved with a power of 23 mW at 447 nm by using a BiB 3 O 6 (BiBO) nonlinear crystal

  20. Diode-pumped CW Nd:SGG laser at 1070 nm

    International Nuclear Information System (INIS)

    Liang, W; Sun, G C; Yu, X; Li, B Z; Jin, G Y

    2011-01-01

    We report for the first time (to our knowledge) a diode-pumped Nd:SGG laser emitting at 1070 nm. A power of 1.23 W at 1070 nm has been achieved in continuous-wave (CW) operation with a fiber-coupled laser diode emitting 18.2 W at 806 nm. Intracavity second-harmonic generation (SHG) in CW mode has also been demonstrated with a power of 328 mW at 535 nm by using a LiB 3 O 5 (LBO) nonlinear crystal. The green beam quality factor M 2 was less than 1.22. The green power stability was less 2.5% in 4 hour

  1. VIIRSN Level-3 Standard Mapped Image, Remote Sensing Reflectance at 671 nm, 8 Day, 4km

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA CoastWatch distributes Remote sensing reflectance (671 nm) data from the NPP-suomi spacecraft. Measurements are gathered by the VIIRS instrument carried aboard...

  2. High-resolution magnetic-domain imaging by Fourier transform holography at 21 nm wavelength

    International Nuclear Information System (INIS)

    Schaffert, Stefan; Pfau, Bastian; Günther, Christian M; Schneider, Michael; Korff Schmising, Clemens von; Eisebitt, Stefan; Geilhufe, Jan

    2013-01-01

    Exploiting x-ray magnetic circular dichroism at the L-edges of 3d transition metals, Fourier transform holography has become a standard technique to investigate magnetic samples with sub-100 nm spatial resolution. Here, magnetic imaging in the 21 nm wavelength regime using M-edge circular dichroism is demonstrated. Ultrafast pulses in this wavelength regime are increasingly available from both laser- and accelerator-driven soft x-ray sources. We explain the adaptations concerning sample preparation and data evaluation compared to conventional holography in the 1 nm wavelength range. We find the correction of the Fourier transform hologram to in-plane Fourier components to be critical for high-quality reconstruction and demonstrate 70 nm spatial resolution in magnetization imaging with this approach. (paper)

  3. 375-nm ultraviolet-laser based non-line-of-sight underwater optical communication

    KAUST Repository

    Sun, Xiaobin; Cai, Wenqi; Alkhazragi, Omar; Ooi, Ee-Ning; He, Hongsen; Chaaban, Anas; Shen, Chao; Oubei, Hassan M.; Khan, Mohammed Zahed Mustafa; Ng, Tien Khee; Alouini, Mohamed-Slim; Ooi, Boon S.

    2018-01-01

    For circumventing the alignment requirement of line-of-sight (LOS) underwater wireless optical communication (UWOC), we demonstrated a non-line-of-sight (NLOS) UWOC link adequately enhanced using ultraviolet (UV) 375-nm laser. Path loss was chosen

  4. Injection Characterization of Packaged Bi-Directional Diamond Shaped Ring Laser at 1550 NM

    National Research Council Canada - National Science Library

    Bussjager, Rebecca; Erdmann, Reinhard; Kovanis, Vassillios; McKeon, Brian; Fanto, Michael; Johns, Steve; Hayduk, Michael J; Osman, Joseph; Morrow, Alan; Green, Malcolm

    2006-01-01

    The Air Force Research Laboratory. Binoptics Corp. and Infotonics Technology Center worked collaboratively to package and characterize recently developed diode based ring lasers that operate at 1550 nm in a diamond shaped cavity...

  5. Optical system for Argus 355-nm 90-mm aperture target-illumination experiments

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, B.C.; Boyd, R.; Hermes, G.; Hildum, J.S.; Linford, G.; Martin, W.E.

    1982-02-01

    The requirements of laser alignment, crystal tuning, target alignment, and laser beam diagnosis are provided by this optical system. Initial setup and preshot alignment techniques are discussed. Layout and operation are contrasted with the 532 nm target experiments.

  6. Characteristics of Charging and Collection of 10-nm-Class Ultrafine Nanoparticles in an Electrostatic Precipitator

    International Nuclear Information System (INIS)

    Han, Bang Woo; Kim, Hak Joon; Kim, Yong Jin; Song, Dong Keun; Hong, Won Seok; Shin, Wan Ho

    2011-01-01

    The charging of 10-nm-class nanoparticles in an electrostatic precipitator (ESP) according to particle charging ratio has been investigated and compared to the diffusion effect of the nanoparticles. The competition between the charging probability and the diffusion loss effect determines the collection efficiency of nanoparticles in the ESP. The collection efficiency of nanoparticles decreased continuously with decreasing particle diameter. This indicates that the partial charging effect of 10-nm-class nanoparticles is more dominant than their diffusion loss effect in the ESP for nanoparticles in the particle size range of less than 10 nm. The charging ratios based on unipolar diffusion charging calculations were in good agreement with the experimental collection efficiencies for nanoparticles less than 10 nm in diameter

  7. Sub-10 nm low current resistive switching behavior in hafnium oxide stack

    Energy Technology Data Exchange (ETDEWEB)

    Hou, Y., E-mail: houyi@pku.edu.cn, E-mail: lfliu@pku.edu.cn [Institute of Microelectronics, Peking University, 100871 Beijing (China); IMEC, Kapeldreef 75, B-3001 Heverlee (Belgium); Department of Physics and Astronomy, KU Leuven, Celestijnenlaan 200D, B-3001 Heverlee (Belgium); Celano, U.; Xu, Z.; Vandervorst, W. [IMEC, Kapeldreef 75, B-3001 Heverlee (Belgium); Department of Physics and Astronomy, KU Leuven, Celestijnenlaan 200D, B-3001 Heverlee (Belgium); Goux, L.; Fantini, A.; Degraeve, R.; Youssef, A.; Jurczak, M. [IMEC, Kapeldreef 75, B-3001 Heverlee (Belgium); Liu, L., E-mail: houyi@pku.edu.cn, E-mail: lfliu@pku.edu.cn; Cheng, Y.; Kang, J. [Institute of Microelectronics, Peking University, 100871 Beijing (China)

    2016-03-21

    In this letter, a tip-induced cell relying on the conductive atomic force microscope is proposed. It is verified as a referable replica of an integrated resistive random access memory (RRAM) device. On the basis of this cell, the functionality of sub-10 nm resistive switching is confirmed in hafnium oxide stack. Moreover, the low current switching behavior in the sub-10 nm dimension is found to be more pronounced than that of a 50 × 50 nm{sup 2} device. It shows better ON/OFF ratio and low leakage current. The enhanced memory performance is ascribed to a change in the shape of the conductive filament as the device dimensions are reduced to sub-10 nm. Therefore, device downscaling provides a promising approach for the resistance optimization that benefits the RRAM array design.

  8. Study on the specificity of yeast cell damage by high-intensity UV radiation (266nm)

    International Nuclear Information System (INIS)

    Burchuladze, T.G.; Frajkin, G.Ya.; Rubin, L.B.

    1981-01-01

    Peculiarities of photoreactivation and photoprotection of the Candida guilliermondii and Candida utilis yeast cells, irradiated with far and near ultraviolet radiation, are considered. New results on the study of the dependence of the cells inactivation degree on the intensity of ultraviolet radiation are presented. The impulse rate density at 266 nm reached 10 10 Ix m -2 xs -1 at the impulse duration of 10 -8 s. Survival curves of the yeast cells during their irradiation with ultraviolet radiation of 266 nm and 254 nm are given. It is shown that with the increase of the irradiation intensity of 266 nm the rates and final levels of photoreactivation decrease. Under the effect of ultraviolet irradiation of high intensity contribution of pyrimidine dimers to the cell inactivation decreases [ru

  9. Design of narrow band photonic filter with compact MEMS for tunable resonant wavelength ranging 100 nm

    Directory of Open Access Journals (Sweden)

    Guanquan Liang

    2011-12-01

    Full Text Available A prototype of planar silicon photonic structure is designed and simulated to provide narrow resonant line-width (∼2 nm in a wide photonic band gap (∼210 nm with broad tunable resonant wavelength range (∼100 nm around the optical communication wavelength 1550 nm. This prototype is based on the combination of two modified basic photonic structures, i.e. a split tapered photonic crystal micro-cavity embedded in a photonic wire waveguide, and a slot waveguide with narrowed slabs. This prototype is then further integrated with a MEMS (microelectromechanical systems based electrostatic comb actuator to achieve “coarse tune” and “fine tune” at the same time for wide range and narrow-band filtering and modulating. It also provides a wide range tunability to achieve the designed resonance even fabrication imperfection occurs.

  10. Remote Sensing Reflectance at 667 nm, Aqua MODIS, NPP, 0.05 degrees, Global, Science Quality

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — MODIS measures the remote sensing reflectance (Rrs) at 667nm. This can be used to view very high concentrations of phytoplankton in the very surface of the water.

  11. Long Term Ultrastable Laser System at 780 nm for Atomic Clocks, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Gener8 and AOSense team together to propose a novel new architecture for a low-phase noise, single-frequency electronically tunable laser at 780 nm. This laser...

  12. Broadband pulsed difference frequency generation laser source centered 3326 nm based on ring fiber lasers

    Science.gov (United States)

    Chen, Guangwei; Li, Wenlei

    2018-03-01

    A broadband pulsed mid-infrared difference frequency generation (DFG) laser source based on MgO-doped congruent LiNbO3 bulk is experimentally demonstrated, which employs a homemade pulsed ytterbium-doped ring fiber laser and a continuous wave erbium-doped ring fiber laser to act as seed sources. The experimental results indicate that the perfect phase match crystal temperature is about 74.5∘C. The maximum spectrum bandwidth of idler is about 60 nm with suitable polarization states of fundamental lights. The central wavelength of idlers varies from 3293 nm to 3333 nm over the crystal temperature ranges of 70.4-76∘C. A jump of central wavelength exists around crystal temperature of 72∘C with variation of about 30 nm. The conversion efficiency of DFG can be tuned with the crystal temperature and polarization states of fundamental lights.

  13. Room temperature synthesis and optical properties of small diameter (5 nm) ZnO nanorod arrays.

    Science.gov (United States)

    Cho, Seungho; Jang, Ji-Wook; Lee, Jae Sung; Lee, Kun-Hong

    2010-10-01

    We report a simple wet-chemical synthesis of ∼5 nm diameter ZnO nanorod arrays at room temperature (20 °C) and normal atmospheric pressure (1 atm) and their optical properties. They were single crystalline in nature, and grew in the [001] direction. These small diameter ZnO nanorod arrays can also be synthesized at 0 °C. Control experiments were also conducted. On the basis of the results, we propose a mechanism for the spontaneous growth of the small diameter ZnO structures. The optical properties of the 5 nm diameter ZnO nanorod arrays synthesized using this method were probed by UV-Visible diffuse reflectance spectroscopy. A clear blue-shift, relative to the absorption band from 50 nm diameter ZnO nanorod arrays, was attributed to the quantum confinement effects caused by the small nanocrystal size in the 5 nm diameter ZnO nanorods.

  14. Anomalous variations of NmF2 over the Argentine Islands: a statistical study

    Directory of Open Access Journals (Sweden)

    A. V. Pavlov

    2009-04-01

    Full Text Available We present a statistical study of variations in the F2-layer peak electron density, NmF2, and altitude, hmF2, over the Argentine Islands ionosonde. The critical frequencies, foF2, and, foE, of the F2 and E-layers, and the propagation factor, M(3000F2, measured by the ionosonde during the 1957–1959 and 1962–1995 time periods were used in the statistical analysis to determine the values of NmF2 and hmF2. The probabilities to observe maximum and minimum values of NmF2 and hmF2 in a diurnal variation of the electron density are calculated. Our study shows that the main part of the maximum diurnal values of NmF2 is observed in a time sector close to midnight in November, December, January, and February exhibiting the anomalous diurnal variations of NmF2. Another anomalous feature of the diurnal variations of NmF2 exhibited during November, December, and January when the minimum diurnal value of NmF2 is mainly located close to the noon sector. These anomalous diurnal variations of NmF2 are found to be during both geomagnetically quiet and disturbed conditions. Anomalous features are not found in the diurnal variations of hmF2. The statistical study of the NmF2 winter anomaly phenomena over the Argentine Islands ionosonde was carried out. The variations in a maximum daytime value, R, of a ratio of a geomagnetically quiet daytime winter NmF2 to a geomagnetically quiet daytime summer NmF2 taken at a given UT and for approximately the same level of solar activity were studied. The conditional probability of the occurrence of R in an interval of R, the most frequent value of R, the mean expected value of R, and the conditional probability to observe the F2-region winter anomaly during a daytime period were calculated for low, moderate, and high solar activity. The calculations show that the mean expected value of R and the occurrence frequency of the F2-region winter anomaly increase with increasing solar activity.

  15. Site Environmental Report, 1993

    Energy Technology Data Exchange (ETDEWEB)

    1994-06-01

    The Site Environmental Report (SER) is prepared annually in accordance with DOE Order 5400.1, ``General Environmental Protection Program.`` This 1993 SER provides the general public as well as scientists and engineers with the results from the site`s ongoing Environmental Monitoring Program. Also included in this report is information concerning the site`s progress toward achieving full compliance with requirements set forth by DOE, US Environmental Protection Agency (USEPA), and Ohio EPA (OEPA). For some readers, the highlights provided in the Executive Summary may provide sufficient information. Many readers, however, may wish to read more detailed descriptions of the information than those which are presented here.

  16. Olkiluoto site description 2011

    International Nuclear Information System (INIS)

    2012-12-01

    This fourth version of the Olkiluoto Site Report, produced by the OMTF (Olkiluoto Modelling Task Force), updates the Olkiluoto Site Report 2008 with the data and knowledge obtained up to December 2010. A descriptive model of the site (the Site Descriptive Model, SDM), i.e. a model describing the geological and hydrogeological structure of the site, properties of the bedrock and the groundwater and its flow, and the associated interacting processes and mechanisms. The SDM is divided into six parts: surface system, geology, rock mechanics, hydrogeology, hydrogeochemistry and transport properties

  17. Olkiluoto site description 2011

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-12-15

    This fourth version of the Olkiluoto Site Report, produced by the OMTF (Olkiluoto Modelling Task Force), updates the Olkiluoto Site Report 2008 with the data and knowledge obtained up to December 2010. A descriptive model of the site (the Site Descriptive Model, SDM), i.e. a model describing the geological and hydrogeological structure of the site, properties of the bedrock and the groundwater and its flow, and the associated interacting processes and mechanisms. The SDM is divided into six parts: surface system, geology, rock mechanics, hydrogeology, hydrogeochemistry and transport properties.

  18. A diode-end-pumped Nd:GYSGG continuous wave laser at 1104 nm

    International Nuclear Information System (INIS)

    Shen, B J; Kang, H X; Zhang, C G; Chen, P; Gao, R L; Liang, J; Gao, H J; Zhang, Q L; Sun, D L; Yin, S T; Luo, J Q

    2013-01-01

    The continuous wave (CW) laser performance of Nd:GYSGG at 1104 nm is investigated for the first time, to our knowledge. A CW laser output power of 4.7 W is obtained when the pump power of the 808 nm fiber coupled laser diode is 19.1 W, corresponding to a conversion efficiency of 24.6% and slope efficiency of 37%. (paper)

  19. Flat-topped emission centred at 1 250 nm from quantum dot superluminescent diodes

    Directory of Open Access Journals (Sweden)

    R.A. Hogg

    2010-01-01

    Full Text Available We present a method for tailoring a broadband and flat-topped emission spectrum in quantum dot superluminescent diodes based upon modification of the dots-in-compositionally-modulated-well (DCMWELL technique. We demonstrate flat-topped emission with 95 nm full width at half maximum (FWHM, centred at 1 250 nm, and with output power in excess of 8 mW.

  20. 300 nm bandwidth adiabatic SOI polarization splitter-rotators exploiting continuous symmetry breaking.

    Science.gov (United States)

    Socci, Luciano; Sorianello, Vito; Romagnoli, Marco

    2015-07-27

    Adiabatic polarization splitter-rotators are investigated exploiting continuous symmetry breaking thereby achieving significant device size and losses reduction in a single mask fabrication process for both SOI channel and ridge waveguides. A crosstalk lower than -25 dB is expected over 300nm bandwidth, making the device suitable for full grid CWDM and diplexer/triplexer FTTH applications at 1310, 1490 and 1550nm.

  1. Three hundred patients treated with ultrapulsed 980 nm diode laser for skin disorders

    Directory of Open Access Journals (Sweden)

    Uwe Wollina

    2016-01-01

    Full Text Available The use of lasers in skin diseases is quite common. In contrast to other laser types, medical literature about 980 nm ultrapulsed diode laser is sparse in dermatology. Herein, we report the use of ultrapulsed diode 980 nm laser in 300 patients with vascular lesions, cysts and pseudocysts, infectious disease, and malignant tumors. This laser is a versatile tool with excellent safety and efficacy in the hands of the experienced user.

  2. Phase-shifted Bragg grating inscription in PMMA microstructured POF using 248 nm UV radiation

    OpenAIRE

    Pereira, L.; Pospori, A.; Antunes, Paulo; Domingues, Maria Fatima; Marques, S.; Bang, Ole; Webb, David J.; Marques, Carlos A.F.

    2017-01-01

    In this work we experimentally validate and characterize the first phase-shifted polymer optical fiber Bragg gratings (PS-POFBGs) produced using a single pulse from a 248 nm krypton fluoride laser. A single-mode poly (methyl methacrylate) optical fiber with a core doped with benzyl dimethyl ketal for photosensitivity improvement was used. A uniform phase mask customized for 850 nm grating inscription was used to inscribe these Bragg structures. The phase shift defect was created directly duri...

  3. Three Hundred Patients Treated with Ultrapulsed 980 nm Diode Laser for Skin Disorders

    Science.gov (United States)

    Wollina, Uwe

    2016-01-01

    The use of lasers in skin diseases is quite common. In contrast to other laser types, medical literature about 980 nm ultrapulsed diode laser is sparse in dermatology. Herein, we report the use of ultrapulsed diode 980 nm laser in 300 patients with vascular lesions, cysts and pseudocysts, infectious disease, and malignant tumors. This laser is a versatile tool with excellent safety and efficacy in the hands of the experienced user. PMID:27688445

  4. Integrated Active and Passive Polymer Optical Components with nm to mm Features

    DEFF Research Database (Denmark)

    Christiansen, Mads Brøkner; Schøler, Mikkel; Kristensen, Anders

    2007-01-01

    We present wafer-scale fabrication of integrated active and passive polymer optics with nm to mm features. First order DFB lasers, defined in dye doped SU-8 resist are integrated with SU-8 waveguides.......We present wafer-scale fabrication of integrated active and passive polymer optics with nm to mm features. First order DFB lasers, defined in dye doped SU-8 resist are integrated with SU-8 waveguides....

  5. 8 nm nanodiamonds as markers for 2 photon excited luminescent microscopy

    International Nuclear Information System (INIS)

    Kharin, A; Rogov, A; Bonacina, L; Geloen, A; Lysenko, V

    2016-01-01

    Structural and luminescent properties of stable suspensions of fluorescent nanodiamonds were investigated. Measurement of the effective hydrodynamic radius yields particles less than 30 nm diameter, while the TEM measurements made on the same particles shows average diameter about 8 nm. It was found that NDs have relatively low toxicity. Upon incubation, 3T3-L1 cells spontaneously take up nanodiamonds that uniformly distribute in cells cytoplasm. The possibility of fluorescent imaging using both single ore two-photon excitation was shown. (paper)

  6. Hanford Site Infrastructure Plan

    International Nuclear Information System (INIS)

    1990-01-01

    The Hanford Site Infrastructure Plan (HIP) has been prepared as an overview of the facilities, utilities, systems, and services that support all activities on the Hanford Site. Its purpose is three-fold: to examine in detail the existing condition of the Hanford Site's aging utility systems, transportation systems, Site services and general-purpose facilities; to evaluate the ability of these systems to meet present and forecasted Site missions; to identify maintenance and upgrade projects necessary to ensure continued safe and cost-effective support to Hanford Site programs well into the twenty-first century. The HIP is intended to be a dynamic document that will be updated accordingly as Site activities, conditions, and requirements change. 35 figs., 25 tabs

  7. Hanford Site Development Plan

    International Nuclear Information System (INIS)

    Hathaway, H.B.; Daly, K.S.; Rinne, C.A.; Seiler, S.W.

    1992-05-01

    The Hanford Site Development Plan (HSDP) provides an overview of land use, infrastructure, and facility requirements to support US Department of Energy (DOE) programs at the Hanford Site. The HSDP's primary purpose is to inform senior managers and interested parties of development activities and issues that require a commitment of resources to support the Hanford Site. The HSDP provides a land use plan for the Hanford Site and presents a picture of what is currently known and anticipated in accordance with DOE Order 4320.1B. Site Development Planning. The HSDP wig be updated annually as future decisions further shape the mission and overall site development process. Further details about Hanford Site development are defined in individual area development plans

  8. Narrow line width operation of a 980 nm gain guided tapered diode laser bar

    DEFF Research Database (Denmark)

    Vijayakumar, Deepak; Jensen, Ole Bjarlin; Barrientos-Barria, Jessica

    2011-01-01

    We demonstrate two different schemes for the spectral narrowing of a 12 emitter 980 nm gain guided tapered diode laser bar. In the first scheme, a reflective grating has been used in a Littman Metcalf configuration and the wavelength of the laser emission could be narrowed down from more than 5.......5 nm in the free running mode to 0.04 nm (FWHM) at an operating current of 30 A with an output power of 8 W. The spectrum was found to be tunable within a range of 16 nm. In the second scheme, a volume Bragg grating has been used to narrow the wavelength of the laser bar from over 5 nm to less than 0.......2 nm with an output of 5 W at 20 A. To our knowledge, this is the first time spectral narrowing has been performed on a gain guided tapered diode laser bar. In the Littman Metcalf configuration, the spectral brightness has been increased by 86 times and in the volume Bragg grating cavity the spectral...

  9. Tapping mode SPM local oxidation nanolithography with sub-10 nm resolution

    International Nuclear Information System (INIS)

    Nishimura, S; Ogino, T; Shirakashi, J; Takemura, Y

    2008-01-01

    Tapping mode SPM local oxidation nanolithography with sub-10 nm resolution is investigated by optimizing the applied bias voltage (V), scanning speed (S) and the oscillation amplitude of the cantilever (A). We fabricated Si oxide wires with an average width of 9.8 nm (V = 17.5 V, S 250 nm/s, A = 292 nm). In SPM local oxidation with tapping mode operation, it is possible to decrease the size of the water meniscus by enhancing the oscillation amplitude of cantilever. Hence, it seems that the water meniscus with sub-10 nm dimensions could be formed by precisely optimizing the oxidation conditions. Moreover, we quantitatively explain the size (width and height) of Si oxide wires with a model based on the oxidation ratio, which is defined as the oxidation time divided by the period of the cantilever oscillation. The model allows us to understand the mechanism of local oxidation in tapping mode operation with amplitude modulation. The results imply that the sub-10 nm resolution could be achieved using tapping mode SPM local oxidation technique with the optimization of the cantilever dynamics

  10. Continuous-wave and passively Q-switched Nd:YVO4 laser at 1085 nm

    Science.gov (United States)

    Lin, Hongyi; Liu, Hong; Huang, Xiaohua; Zhang, Jiyan

    2017-11-01

    An admirable and efficient Nd:YVO4 laser at 1085 nm is demonstrated with a compact 35 mm plano-plano cavity. A chosen narrow bandpass filter with high-transmittance (HT) coating at 1064 nm (T=96%) and optimized part-reflection (PR) coating at 1085 nm (T=15%) is used as the output coupler. In the continuous-wave (CW) regime, the maximum output power reaches 3110 mW at the pump power of 11.41 W. Based on a Cr:YAG crystal with initial-transmittance of 91%, the first passively Q-switched Nd:YVO4 laser at 1085 nm is achieved. When the pump power is changed from the threshold of 4.50 to 6.08 W, the dual-wavelength lines at 1064 and 1085 nm are generated simultaneously. However, at the pump power of above 6.08 W, the single-wavelength line at 1085 nm is achieved. The largest output power, the highest peak power, and the narrowest pulse width are 1615 mW, 878 W and 26.2 ns, respectively.

  11. Pre-storm NmF2 enhancements at middle latitudes: delusion or reality?

    Directory of Open Access Journals (Sweden)

    A. V. Mikhailov

    2009-03-01

    Full Text Available A critical analysis of recent publications devoted to the NmF2 pre-storm enhancements is performed. There are no convincing arguments that the observed cases of NmF2 enhancements at middle and sub-auroral latitudes bear a relation to the following magnetic storms. In all cases considered the NmF2 pre-storm enhancements were due to previous geomagnetic storms, moderate auroral activity or they presented the class of positive quiet time events (Q-disturbances. Therefore, it is possible to conclude that there is no such an effect as the pre-storm NmF2 enhancement as a phenomenon inalienably related to the following magnetic storm. The observed nighttime NmF2 enhancements at sub-auroral latitudes may result from plasma transfer from the plasma ring area by meridional thermospheric wind. Enhanced plasmaspheric fluxes into the nighttime F2-region resulted from westward substorm-associated electric fields is another possible source of nighttime NmF2 enhancements. Daytime positive Q-disturbances occurring under very low geomagnetic activity level may be related to the dayside cusp activity.

  12. Sub-10-nm suspended nano-web formation by direct laser writing

    Science.gov (United States)

    Wang, Sihao; Yu, Ye; Liu, Hailong; Lim, Kevin T. P.; Madurai Srinivasan, Bharathi; Zhang, Yong Wei; Yang, Joel K. W.

    2018-06-01

    A diffraction-limited three-dimensional (3D) direct laser writing (DLW) system based on two-photon polymerization can routinely pattern structures at the 100 nm length scale. Several schemes have been developed to improve the patterning resolution of 3D DLW but often require customized resist formulations or multi-wavelength exposures. Here, we introduce a scheme to produce suspended nano-webs with feature sizes below 10 nm in IP-Dip resist using sub-threshold exposure conditions in a commercial DLW system. The narrowest suspended lines (nano-webs) measured 7 nm in width. Larger ∼20 nm nano-webs were patterned with ∼80% yield at increased laser powers. In addition, closely spaced nano-gaps with a center-to-center distance of 33 nm were produced by patterning vertically displaced suspended lines followed by metal deposition and liftoff. We provide hypotheses and present preliminary results for a mechanism involving the initiation of a percolative path and a strain-induced narrowing in the nano-web formation. Our approach allows selective features to be patterned with dimensions comparable to the sub-10 nm patterning capability of electron-beam lithography (EBL).

  13. Mechanisms involved in HBr and Ar cure plasma treatments applied to 193 nm photoresists

    International Nuclear Information System (INIS)

    Pargon, E.; Menguelti, K.; Martin, M.; Bazin, A.; Joubert, O.; Chaix-Pluchery, O.; Sourd, C.; Derrough, S.; Lill, T.

    2009-01-01

    In this article, we have performed detailed investigations of the 193 nm photoresist transformations after exposure to the so-called HBr and Ar plasma cure treatments using various characterization techniques (x-ray photoelectron spectroscopy, Fourier transformed infrared, Raman analyses, and ellipsometry). By using windows with different cutoff wavelengths patched on the photoresist film, the role of the plasma vacuum ultraviolet (VUV) light on the resist modifications is clearly outlined and distinguished from the role of radicals and ions from the plasma. The analyses reveal that both plasma cure treatments induce severe surface and bulk chemical modifications of the resist films. The synergistic effects of low energetic ion bombardment and VUV plasma light lead to surface graphitization or cross-linking (on the order of 10 nm), while the plasma VUV light (110-210 nm) is clearly identified as being responsible for ester and lactone group removal from the resist bulk. As the resist modification depth depends strongly on the wavelength penetration into the material, it is found that HBr plasma cure that emits near 160-170 nm can chemically modify the photoresist through its entire thickness (240 nm), while the impact of Ar plasmas emitting near 100 nm is more limited. In the case of HBr cure treatment, Raman and ellipsometry analyses reveal the formation of sp 2 carbon atoms in the resist bulk, certainly thanks to hydrogen diffusion through the resist film assisted by the VUV plasma light.

  14. Absolute cross sections for emission of 284.7-nm (Hg II) and 479.7-nm (Hg III) radiation in electron--mercury-ion collisions

    International Nuclear Information System (INIS)

    Phaneuf, R.A.; Taylor, P.O.; Dunn, G.H.

    1976-01-01

    Crossed beams of electrons and Hg + ions have been used to measure absolute cross sections for emission of 284.7-nm radiation, resulting from excitation of a predominantly ground-state Hg + target to the 7s 2 S 1 / 2 state. Values range from 3 x 10 -17 cm 2 near threshold, where the cross section is strongly peaked, to 1.3 x 10 -18 cm 2 at 280 eV. Also reported are some measurements of emission of 479.7-nm (Hg III) radiation, resulting from electron impact on both Hg + and Hg ++ targets. Cross sections range from approximately 5 x 10 -19 to 5 x 10 -20 cm 2 , and in the case of electron-Hg ++ collisions, are more than an order of magnitude smaller than predicted by an available semiclassical binary-encounter calculation

  15. Comparison of 850-nm and 1550-nm VCSELs for low-cost short-reach IM/DD and OFDM SMF/MMF links

    DEFF Research Database (Denmark)

    Karinou, Fotini; Deng, Lei; Rodes Lopez, Roberto

    2013-01-01

    In this paper, we experimentally compare the suitability of two VCSEL designs of different wavelength and technology as inexpensive, off-the-shelf transmitter components to enable low-cost and energy-efficient optical interconnects employing conventional (NRZ IM/DD) and advanced (OFDM) modulation....... In particular, we assess the performance of a multimode (MM) 850-nm and a single-mode (SM) 1550-nm VCSEL over 100 m/1 km of 50.7-μm diameter OM-4 MMF links and 100 m/5 km SMF links. OFDM-QPSK is investigated in order to substitute IM/DD in order to increase the capacity in the aforementioned VCSEL-based, MMF...

  16. Irradiation Effect of Argon Ion on Interfacial Structure Fe(2nm/Si(tsi=0.5-2 nm Multilayer thin Film

    Directory of Open Access Journals (Sweden)

    S. Purwanto

    2010-04-01

    Full Text Available Investigation includes formation of interfacial structure of Fe(2nm/Si(tSi= 0.5-2 nm multilayer thin film and the behavior of antiferromagnetic coupling between Fe layers due to Argon ion irradiation was investigated. [Fe(2nm/Si]30 multilayers (MLs with a thickness of Si spacer 0.5 - 2 nanometer were prepared on n-type (100 Si substrate by the helicon plasma sputtering method. Irradiation were performed using 400keV Ar ion to investigate the behavior of magnetic properties of the Fe/Si MLs. The magnetization measurements of Fe/Si MLs after 400keV Ar ion irradiation show the degradation of antiferromagnetic behavior of Fe layers depend on the ion doses. The Magnetoresistance (MR measurements using by Four Point Probe (FPP method also confirm that MR ratio decrease after ion irradiation. X-ray diffraction (XRD patterns indicate that the intensity of a satellite peak induced by a superlattice structure does not change within the range of ion dose. These results imply that the surface of interface structures after ion irradiation become rough although the layer structures are maintained. Therefore, it is considered that the MR properties of Fe/Si MLs also are due to the metallic superlattice structures such as Fe/Cr and Co/Cu MLs.

  17. Complete resolution of minocycline pigmentation following a single treatment with non-ablative 1550-nm fractional resurfacing in combination with the 755-nm Q-switched alexandrite laser.

    Science.gov (United States)

    Vangipuram, Ramya K; DeLozier, Whitney L; Geddes, Elizabeth; Friedman, Paul M

    2016-03-01

    Pigmentation secondary to minocycline ingestion is an uncommon adverse event affecting 3.7-14.8% of treated individuals for which few effective therapies are available. Three patterns of minocycline pigmentation have a characteristic clinical and histological appearance. The pigment composition in each variety is different and occurs at varying skin depths. Accordingly, a tailored approach according to the type of minocycline pigmentation is crucial for treatment success. The purpose of this intervention was to evaluate the efficacy of non-ablative fractional photothermolysis in combination with the Q-switched alexandrite laser for the treatment of type I minocycline pigmentation on the face. A patient with type I minocycline pigmentation was treated with non-ablative 1550-nm fractional photothermolysis followed immediately by 755-nm Q-switched alexandrite laser and then observed clinically to determine the outcome of this modality. The patient was seen in clinic 1 month later following her single treatment session and 100% clearance of all blue facial pigment was observed. Non-ablative fractional photothermolysis in combination with the 755-nm Q-switched alexandrite laser should be considered for treatment of type I minocycline pigmentation. © 2015 Wiley Periodicals, Inc.

  18. Simultaneous measurements of new particle formation at 1 s time resolution at a street site and a rooftop site

    Science.gov (United States)

    Zhu, Yujiao; Yan, Caiqing; Zhang, Renyi; Wang, Zifa; Zheng, Mei; Gao, Huiwang; Gao, Yang; Yao, Xiaohong

    2017-08-01

    This study is the first to use two identical Fast Mobility Particle Sizers for simultaneous measurement of particle number size distributions (PNSDs) at a street site and a rooftop site within 500 m distance in wintertime and springtime to investigate new particle formation (NPF) in Beijing. The collected datasets at 1 s time resolution allow deduction of the freshly emitted traffic particle signal from the measurements at the street site and thereby enable the evaluation of the effects on NPF in an urban atmosphere through a site-by-site comparison. The number concentrations of 8 to 20 nm newly formed particles and the apparent formation rate (FR) in the springtime were smaller at the street site than at the rooftop site. In contrast, NPF was enhanced in the wintertime at the street site with FR increased by a factor of 3 to 5, characterized by a shorter NPF time and higher new particle yields than at the rooftop site. Our results imply that the street canyon likely exerts distinct effects on NPF under warm or cold ambient temperature conditions because of on-road vehicle emissions, i.e., stronger condensation sinks that may be responsible for the reduced NPF in the springtime but efficient nucleation and partitioning of gaseous species that contribute to the enhanced NPF in the wintertime. The occurrence or absence of apparent growth for new particles with mobility diameters larger than 10 nm was also analyzed. The oxidization of biogenic organics in the presence of strong photochemical reactions is suggested to play an important role in growing new particles with diameters larger than 10 nm, but sulfuric acid is unlikely to be the main species for the apparent growth. However, the number of datasets used in this study is relatively small, and larger datasets are essential to draw a general conclusion.

  19. Site characterization plan:

    International Nuclear Information System (INIS)

    1988-01-01

    The Yucca Mountain site in Nevada is one of three candidate sites for the first geologic repository for radioactive waste. On May 28, 1986, it was recommended for detailed study in a program of site characterization. This site characterization plan (SCP) has been prepared in accordance with the requirements of the Nuclear Waste Policy Act to summarize the information collected to date about the geologic conditions at the site;to describe the conceptual designs for the repository and the waste package;and to present the plans for obtaining the geologic information necessary to demonstrate the suitability of the site for repository, to design the repository and the waste package, to prepare an environmental impact statement, and to obtain from the US Nuclear Regulatory Commission (NRC) an authorization to construct the repository. This introduction begins with a brief section on the process for siting and developing a repository, followed by a discussion of the pertinent legislation and regulations. A description of site characterization is presented next;it describes the facilities to be constructed for the site characterization program and explains the principal activities to be conducted during the program. Finally, the purpose, content, organizing principles, and organization of this site characterization plan are outlined, and compliance with applicable regulations is discussed

  20. Site characterization plan:

    International Nuclear Information System (INIS)

    1988-01-01

    The Yucca Mountain site in Nevada is one of three candidate sites for the first geologic repository for radioactive waste. On May 28, 1986, it was recommended for detailed study in a program of site characterization. This site characterization plan (SCP) has been prepared in acordance with the requirements of the Nuclear Waste Policy Act to summarize the information collected to date about the geologic conditions at the site;to describe the conceptual designs for the repository and the waste package and to present the plans for obtaining the geologic information necessary to demonstrate the suitability of the site for a repository, to design the repository and the waste package, to prepare an environmental impact statement, and to obtain from the US Nuclear Regulatory Commission (NRC) an authorization to construct the repository. This introduction begins with a brief section on the process for siting and eveloping a repository, followed by a discussion of the pertinent legislation and regulations. A description of site characterization is presented next;it describes the facilities to be constructed for the site characterization program and explains the principal activities to be conducted during the program. Finally, the purpose, content, organizing prinicples, and organization of this site characterization plan are outlined, and compliance with applicable regulations is discussed. 880 refs., 130 figs., 25 tabs

  1. Removal of sulfamethoxazole, ibuprofen and nitrobenzene by UV and UV/chlorine processes: A comparative evaluation of 275 nm LED-UV and 254 nm LP-UV.

    Science.gov (United States)

    Kwon, Minhwan; Yoon, Yeojoon; Kim, Seonbaek; Jung, Youmi; Hwang, Tae-Mun; Kang, Joon-Wun

    2018-05-15

    The aim of this study is to evaluate the micropollutant removal capacity of a 275 nm light-emitting diode (LED)-UV/chlorine system. The sulfamethoxazole, ibuprofen, and nitrobenzene removal efficiencies of this system were compared with those of a conventional 254 nm low-pressure (LP)-UV system as a function of the UV dose. In a direct photolysis system, the photon reactivity of sulfamethoxazole is higher than that of nitrobenzene and ibuprofen at both wavelengths. The molar absorption coefficients and quantum yields of each micropollutant were as follows: sulfamethoxazole (ε SMX, 275 nm protonated  = 17,527 M -1  cm -1 , Φ SMX, 275 nm protonated  = 0.239, ε SMX, 275 nm deprotonated  = 8430 M -1  cm -1 , and Φ SMX, 275 nm deprotonated  = 0.026), nitrobenzene (ε NB, 275 nm  = 7176 M -1  cm -1 and Φ NB, 275 nm  = 0.057), and ibuprofen (ε NB, 275 nm  = 200 M -1  cm -1 and Φ IBF, 275 nm  = 0.067). The photon reactivity of chlorine species, i.e., HOCl and OCl-, were determined at 275 nm (ε HOCl, 275 nm  = 28 M -1  cm -1 , Φ HOCl, 275 nm  = 1.97, ε OCl-, 275 nm  = 245 M -1  cm -1 , and Φ OCl-, 275 nm  = 0.8), which indicate that the decomposition rate of OCl - is higher and that of HOCl is lower by 275 nm photolysis than that by 254 nm photolysis (ε HOCl, 254 nm  = 60 M -1  cm -1 , Φ HOCl, 254 nm  = 1.46, ε OCl-, 254 nm  = 58 M -1  cm -1 , and Φ OCl-, 254 nm  = 1.11). In the UV/chlorine system, the removal rates of ibuprofen and nitrobenzene were increased by the formation of OH and reactive chlorine species. The 275-nm LED-UV/chlorine system has higher radical yields at pH 7 and 8 than the 254 nm LP-UV/chlorine system. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. In Vitro Study of Dentin Hypersensitivity Treated by 980-nm Diode Laser.

    Science.gov (United States)

    Liu, Ying; Gao, Jie; Gao, Yan; Xu, Shuaimei; Zhan, Xueling; Wu, Buling

    2013-01-01

    To investigate the ultrastructural changes of dentin irradiated with 980-nm diode laser under different parameters and to observe the morphological alterations of odontoblasts and pulp tissue to determine the safety parameters of 980-nm diode laser in the treatment of dentin hypersensitivity (DH). Twenty extracted human third molars were selected to prepare dentin discs. Each dentin disc was divided into four areas and was irradiated by 980-nm diode laser under different parameters: Group A: control group, 0 J/cm(2); Group B: 2 W/CW (continuous mode), 166 J/cm(2); Group C: 3W/CW, 250 J/cm(2); and Group D: 4W/CW, 333 J/cm(2). Ten additional extracted human third molars were selected to prepare dentin discs. Each dentin disc was divided into two areas and was irradiated by 980-nm diode laser: Group E: control group, 0 J/cm(2); and Group F: 2.0 W/CW, 166 J/cm(2). The morphological alterations of the dentin surfaces and odontoblasts were examined with scanning electron microscopy (SEM), and the morphological alterations of the dental pulp tissue irradiated by laser were observed with an upright microscope. The study demonstrated that dentinal tubules can be entirely blocked after irradiation by 980-nm diode laser, regardless of the parameter setting. Diode laser with settings of 2.0 W and 980-nm sealed exposed dentin tubules effectively, and no significant morphological alterations of the pulp and odontoblasts were observed after irradiation. Irradiation with 980-nm diode laser could be effective for routine clinical treatment of DH, and 2.0W/CW (166 J/cm(2)) was a suitable energy parameter due to its rapid sealing of the exposed dentin tubules and its safety to the odontoblasts and pulp tissue.

  3. MYBPH inhibits NM IIA assembly via direct interaction with NMHC IIA and reduces cell motility

    International Nuclear Information System (INIS)

    Hosono, Yasuyuki; Usukura, Jiro; Yamaguchi, Tomoya; Yanagisawa, Kiyoshi; Suzuki, Motoshi; Takahashi, Takashi

    2012-01-01

    Highlights: ► MYBPH inhibits NMHC IIA assembly and cell motility. ► MYBPH interacts to assembly-competent NM IIA. ► MYBPH inhibits RLC and NMHC IIA, independent components of NM IIA. -- Abstract: Actomyosin filament assembly is a critical step in tumor cell migration. We previously found that myosin binding protein H (MYBPH) is directly transactivated by the TTF-1 lineage-survival oncogene in lung adenocarcinomas and inhibits phosphorylation of the myosin regulatory light chain (RLC) of non-muscle myosin IIA (NM IIA) via direct interaction with Rho kinase 1 (ROCK1). Here, we report that MYBPH also directly interacts with an additional molecule, non-muscle myosin heavy chain IIA (NMHC IIA), which was found to occur between MYBPH and the rod portion of NMHC IIA. MYBPH inhibited NMHC IIA assembly and reduced cell motility. Conversely, siMYBPH-induced increased motility was partially, yet significantly, suppressed by blebbistatin, a non-muscle myosin II inhibitor, while more profound effects were attained by combined treatment with siROCK1 and blebbistatin. Electron microscopy observations showed well-ordered paracrystals of NMHC IIA reflecting an assembled state, which were significantly less frequently observed in the presence of MYBPH. Furthermore, an in vitro sedimentation assay showed that a greater amount of NMHC IIA was in an unassembled state in the presence of MYBPH. Interestingly, treatment with a ROCK inhibitor that impairs transition of NM IIA from an assembly-incompetent to assembly-competent state reduced the interaction between MYBPH and NMHC IIA, suggesting that MYBPH has higher affinity to assembly-competent NM IIA. These results suggest that MYBPH inhibits RLC and NMHC IIA, independent components of NM IIA, and negatively regulates actomyosin organization at 2 distinct steps, resulting in firm inhibition of NM IIA assembly.

  4. Evidence for stepwise dissociation dynamics in acetone at 248 and 193 nm

    Science.gov (United States)

    North, Simon W.; Blank, David A.; Gezelter, J. Daniel; Longfellow, Cheryl A.; Lee, Yuan T.

    1995-03-01

    The technique of molecular beam photofragment translational spectroscopy has been used to study the dissociation of acetone following S1←S0 (248 nm) and S2←S0 (193 nm) excitation. Excitation at 248 nm resulted in the production of CH3 and CH3CO with 14.2±1.0 kcal/mole on average of the available energy appearing as translation of the photofragments. Comparison of the measured with values reported at 266 nm suggest that the energy partitioning is dominated by the exit barrier caused by an avoided crossing on the potential energy surface. A substantial fraction (30±4%) of the nascent acetyl radicals from the primary dissociation contain sufficient energy to undergo spontaneous secondary decomposition. From the onset of the truncation of the CH3CO P(ET) a threshold of 17.8±3.0 kcal/mole for the dissociation of the acetyl radical has been determined in agreement with recent results on the photodissociation of acetyl chloride. The translational energy release in the dissociation of CH3CO closely matches the experimentally determined exit barrier. At 193 nm the only observed dissociation pathway was the formation of two methyl radicals and carbon monoxide. On average ˜38% of the available energy is found in product translation suggesting that significant internal energy resides in the nascent CH3 fragments consistent with the results of Hall et al. [J. Chem. Phys. 94, 4182 (1991)]. We conclude that the dynamics and energy partitioning for dissociation at 193 nm is similar to that at 248 nm.

  5. In Vitro Study of Dentin Hypersensitivity Treated by 980-nm Diode Laser

    Science.gov (United States)

    Liu, Ying; Gao, Jie; Gao, Yan; XU, Shuaimei; Zhan, Xueling; Wu, Buling

    2013-01-01

    Introduction: To investigate the ultrastructural changes of dentin irradiated with 980-nm diode laser under different parameters and to observe the morphological alterations of odontoblasts and pulp tissue to determine the safety parameters of 980-nm diode laser in the treatment of dentin hypersensitivity (DH). Methods: Twenty extracted human third molars were selected to prepare dentin discs. Each dentin disc was divided into four areas and was irradiated by 980-nm diode laser under different parameters: Group A: control group, 0 J/cm2; Group B: 2 W/CW (continuous mode), 166 J/cm2; Group C: 3W/CW, 250 J/cm2; and Group D: 4W/CW, 333 J/cm2. Ten additional extracted human third molars were selected to prepare dentin discs. Each dentin disc was divided into two areas and was irradiated by 980-nm diode laser: Group E: control group, 0 J/cm2; and Group F: 2.0 W/CW, 166 J/cm2. The morphological alterations of the dentin surfaces and odontoblasts were examined with scanning electron microscopy (SEM), and the morphological alterations of the dental pulp tissue irradiated by laser were observed with an upright microscope. Results: The study demonstrated that dentinal tubules can be entirely blocked after irradiation by 980-nm diode laser, regardless of the parameter setting. Diode laser with settings of 2.0 W and 980-nm sealed exposed dentin tubules effectively, and no significant morphological alterations of the pulp and odontoblasts were observed after irradiation. Conclusions: Irradiation with 980-nm diode laser could be effective for routine clinical treatment of DH, and 2.0W/CW (166 J/cm2) was a suitable energy parameter due to its rapid sealing of the exposed dentin tubules and its safety to the odontoblasts and pulp tissue. PMID:25606318

  6. Site environmental programs

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, J.W.; Hanf, R.W.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the site environmental programs. Effluent monitoring and environmental surveillance programs monitor for impacts from operations in several areas. The first area consists of the point of possible release into the environment. The second area consists of possible contamination adjacent to DOE facilities, and the third area is the general environment both on and off the site.

  7. Site environmental report summary

    International Nuclear Information System (INIS)

    1992-01-01

    In this summary of the Fernald 1992 Site Environmental Report the authors will describe the impact of the Fernald site on man and the environment and provide results from the ongoing Environmental Monitoring Program. Also included is a summary of the data obtained from sampling conducted to determine if the site complies with DOE, US Environmental Protection Agency (USEPA), and Ohio EPA (OEPA) requirements. These requirements are set to protect both man and the environment

  8. Site environmental programs

    International Nuclear Information System (INIS)

    Schmidt, J.W.; Hanf, R.W.

    1995-01-01

    This section of the 1994 Hanford Site Environmental Report summarizes the site environmental programs. Effluent monitoring and environmental surveillance programs monitor for impacts from operations in several areas. The first area consists of the point of possible release into the environment. The second area consists of possible contamination adjacent to DOE facilities, and the third area is the general environment both on and off the site

  9. CERCLA site assessment workbook

    International Nuclear Information System (INIS)

    1994-08-01

    This contains comments for each chapter of exercises (in Vol. 1) which illustrate how to conduct site assessments for CERCLA regulation. A through analysis of the exercises is provided so that work and solutions from Vol 1 can be critiqued and comments are also included on the strategy of site assessment whereas the exercises illustrate the principles involved. Covered exercises include the following: A preliminary assessment of a ground water site; waste characteristics and characterization of sources; documentation of observed releases and actual contamination of targets; the strategy of an SI at a surface water site; the soil exposure pathway; the air pathway

  10. Nuclear site selection studies

    International Nuclear Information System (INIS)

    Gharib, A.; Zohoorian Izadpanah, A.A.; Iranmanesh, H.

    2000-01-01

    It is of special importance, especially from the nuclear safety viewpoint, to select suitable sites for different nuclear structures with the considered future activities. Site selection sometimes involves high costs not necessarily for merely selecting of site but for some preliminary measures to be taken so as the site may have the necessary characteristics. The more suitable the natural characteristics of the site for the considered project, the more successful and efficient the project, the lower the project costs and the longer the project operation period. If so, the project will cause the growth of public culture and sustainable socioeconomic development. This paper is the result of the conclusion of numerous massive reports of this activity in the preliminary phase based on theories, practices and the related safety principles on this ground as well as the application of data and information of the past and a glance to the future. The conception of need for a site for medium structures and nuclear research projects and how to perform this process are presented step by step here with a scientific approach to its selection during the investigations. In this study, it is practically described how the site is selected, by determining and defining the characteristics of research and nuclear projects with medium structures and also its fitting to the optimum site. The discovered sites typically involve the best advantages in technical and economic aspects and no particular contrast with the concerned structures

  11. Meteorology in site operations

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    During the site selection and design phases of a plant, meteorological assistance must be based on past records, usually accumulated at stations not actually on the site. These preliminary atadvices will be averages and extremes that might be expected. After a location has been chosen and work has begun, current and forecast weather conditions become of immediate concern. On-site meteorological observations and forecasts have many applications to the operating program of an atomic energy site. Requirements may range from observations of the daily minimum temperatures to forecasts of radiation dosages from airborne clouds

  12. 1994 Site environmental report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-07-01

    The Fernald site is a Department of Energy (DOE)-owned facility that produced high-quality uranium metals for military defense for nearly 40 years. DOE suspended production at the site in 1989 and formally ended production in 1991. Although production activities have ceased, the site continues to examine the air and liquid pathways as possible routes through which pollutants from past operations and current remedial activities may leave the site. The Site Environmental Report (SER) is prepared annually in accordance with DOE Order 5400.1, General Environmental Protection Program. This 1994 SER provides the general public as well as scientists and engineers with the results from the site`s ongoing Environmental Monitoring Program. Also included in this report is information concerning the site`s progress toward achieving full compliance with requirements set forth by DOE, U.S. Environmental Protection Agency (USEPA), and Ohio EPA (OEPA). For some readers, the highlights provided in this Executive Summary may provide sufficient information. Many readers, however, may wish to read more detailed descriptions of the information than those which are presented here. All information presented in this summary is discussed more fully in the main body of this report.

  13. Negative-tone imaging with EUV exposure for 14nm hp and beyond

    Science.gov (United States)

    Tsubaki, Hideaki; Nihashi, Wataru; Tsuchihashi, Toru; Fujimori, Toru; Momota, Makoto; Goto, Takahiro

    2015-03-01

    Manipulation of dissolution properties by changing organic solvent developer and rinse material provides a novel technology to obtain fine pattern beyond the limitation of imaging system based on alkaline developer. QCM study showed no swelling character in negative-tone imaging (NTI) process even for current developer of n-butyl acetate (nBA). Actually, NTI process has shown advantages on resolution and line-width roughness (LWR) in loose pitch around 30 ~ 45 nm hp as a consequence of its non-swelling character. On the other hand, bridge and collapse limited its resolution below 20 nm hp, indicating that non-negligible amount of swelling still exists for tight pitch resolution. We investigated effects of solubility parameter of organic solvents on resolution below 20 nm hp. A bridge was reduced with a decrease in the solubility parameter dp from nBA. On the other hand, much lower dp caused film remaining due to its extremely slow Rmax. Based on these results, we newly developed FN-DP301 containing organic solvent with smaller dp than nBA. Although rinse solvent gave negligible effects on bridge, there is a clear improvement on pattern collapse only in case of using new rinse solvent of FN-RP311. Lithographic performances of NTI process using nBA and FN-DP301 together with the other organic solvents were described in this paper under exposures with an E-beam and a EUV light. It is emphasized that 14 nm hp resolution was obtained only using FN-DP301 as a developer and FN-RP311 as a rinse under E-beam exposure. NTI showed 43% faster photospeed in comparison with PTI at 16 nm hp, indicating that NTI is applicable to obtain high throughput with maintaining resolution. In addition, sub-20 nm trench was obtained using NTI without bridge under EUV exposure, all of which are attributed to the low swelling character of NTI process. Similarly, NTI was able to print 20 nm dots using NXE:3100 with only a little peeling. Conversely CH patterning was significantly worse with NTI

  14. Optical breakdown threshold investigation of 1064 nm laser induced air plasmas

    International Nuclear Information System (INIS)

    Thiyagarajan, Magesh; Thompson, Shane

    2012-01-01

    We present the theoretical and experimental measurements and analysis of the optical breakdown threshold for dry air by 1064 nm infrared laser radiation and the significance of the multiphoton and collisional cascade ionization process on the breakdown threshold measurements over pressures range from 10 to 2000 Torr. Theoretical estimates of the breakdown threshold laser intensities and electric fields are obtained using two distinct theories namely multiphoton and collisional cascade ionization theories. The theoretical estimates are validated by experimental measurements and analysis of laser induced breakdown processes in dry air at a wavelength of 1064 nm by focusing 450 mJ max, 6 ns, 75 MW max high-power 1064 nm IR laser radiation onto a 20 μm radius spot size that produces laser intensities up to 3 - 6 TW/cm 2 , sufficient for air ionization over the pressures of interest ranging from 10 to 2000 Torr. Analysis of the measured breakdown threshold laser intensities and electric fields are carried out in relation with classical and quantum theoretical ionization processes, operating pressures. Comparative analysis of the laser air breakdown results at 1064 nm with corresponding results of a shorter laser wavelength (193 nm) [M. Thiyagarajan and J. E. Scharer, IEEE Trans. Plasma Sci. 36, 2512 (2008)] and a longer microwave wavelength (10 8 nm) [A. D. MacDonald, Microwave Breakdown in Gases (Wiley, New York, 1966)]. A universal scaling analysis of the breakdown threshold measurements provided a direct comparison of breakdown threshold values over a wide range of frequencies ranging from microwave to ultraviolet frequencies. Comparison of 1064 nm laser induced effective field intensities for air breakdown measurements with data calculated based on the collisional cascade and multiphoton breakdown theories is used successfully to determine the scaled collisional microwave portion. The measured breakdown threshold of 1064 nm laser intensities are then scaled to

  15. Sub-4 nm PtZn Intermetallic Nanoparticles for Enhanced Mass and Specific Activities in Catalytic Electrooxidation Reaction

    International Nuclear Information System (INIS)

    Qi, Zhiyuan

    2017-01-01

    Atomically ordered intermetallic nanoparticles (iNPs) have sparked considerable interest in fuel cell applications by virtue of their exceptional electronic and structural properties. However, the synthesis of small iNPs in a controllable manner remains a formidable challenge because of the high temperature generally required in the formation of intermetallic phases. Here in this paper we report a general method for the synthesis of PtZn iNPs (3.2 ± 0.4 nm) on multiwalled carbon nanotubes (MWNT) via a facile and capping agent free strategy using a sacrificial mesoporous silica (mSiO 2 ) shell. The as-prepared PtZn iNPs exhibited ca. 10 times higher mass activity in both acidic and basic solution toward the methanol oxidation reaction (MOR) compared to larger PtZn iNPs synthesized on MWNT without the mSiO 2 shell. Density functional theory (DFT) calculations predict that PtZn systems go through a “non-CO” pathway for MOR because of the stabilization of the OH* intermediate by Zn atoms, while a pure Pt system forms highly stable COH* and CO* intermediates, leading to catalyst deactivation. Experimental studies on the origin of the backward oxidation peak of MOR coincide well with DFT predictions. Moreover, the calculations demonstrate that MOR on smaller PtZn iNPs is energetically more favorable than larger iNPs, due to their high density of corner sites and lower-lying energetic pathway. Therefore, smaller PtZn iNPs not only increase the number but also enhance the activity of the active sites in MOR compared with larger ones. This work opens a new avenue for the synthesis of small iNPs with more undercoordinated and enhanced active sites for fuel cell applications.

  16. REBL: design progress toward 16 nm half-pitch maskless projection electron beam lithography

    Science.gov (United States)

    McCord, Mark A.; Petric, Paul; Ummethala, Upendra; Carroll, Allen; Kojima, Shinichi; Grella, Luca; Shriyan, Sameet; Rettner, Charles T.; Bevis, Chris F.

    2012-03-01

    REBL (Reflective Electron Beam Lithography) is a novel concept for high speed maskless projection electron beam lithography. Originally targeting 45 nm HP (half pitch) under a DARPA funded contract, we are now working on optimizing the optics and architecture for the commercial silicon integrated circuit fabrication market at the equivalent of 16 nm HP. The shift to smaller features requires innovation in most major subsystems of the tool, including optics, stage, and metrology. We also require better simulation and understanding of the exposure process. In order to meet blur requirements for 16 nm lithography, we are both shrinking the pixel size and reducing the beam current. Throughput will be maintained by increasing the number of columns as well as other design optimizations. In consequence, the maximum stage speed required to meet wafer throughput targets at 16 nm will be much less than originally planned for at 45 nm. As a result, we are changing the stage architecture from a rotary design to a linear design that can still meet the throughput requirements but with more conventional technology that entails less technical risk. The linear concept also allows for simplifications in the datapath, primarily from being able to reuse pattern data across dies and columns. Finally, we are now able to demonstrate working dynamic pattern generator (DPG) chips, CMOS chips with microfabricated lenslets on top to prevent crosstalk between pixels.

  17. Fluorescence-based calculus detection using a 405-nm excitation wavelength

    Science.gov (United States)

    Brede, O.; Schelle, F.; Krueger, S.; Oehme, B.; Dehn, C.; Frentzen, M.; Braun, A.

    2011-03-01

    The aim of this study was to assess the difference of fluorescence signals of cement and calculus using a 405 nm excitation wavelength. A total number of 20 freshly extracted teeth was used. The light source used for this study was a blue LED with a wavelength of 405nm. For each tooth the spectra of calculus and cementum were measured separately. Fluorescence light was collimated into an optical fibre and spectrally analyzed using an echelle spectrometer (aryelle 200, Lasertechnik Berlin, Germany) with an additionally bandpass (fgb 67, Edmund Industrial Optics, Karlsruhe, Germany). From these 40 measurements the median values were calculated over the whole spectrum, leading to two different median spectra, one for calculus and one for cementum. For further statistical analysis we defined 8 areas of interest (AOI) in wavelength regions, showing remarkable differences in signal strength. In 7 AOIs the intensity of the calculus spectrum differed statistically significant from the intensity of the cementum spectrum (p calculus and cement between 600nm and 700nm. Thus, we can conclude that fluorescence of calculus shows a significant difference to the fluorescence of cement. A differentiation over the intensity is possible as well as over the spectrum. Using a wavelength of 405nm, it is possible to distinguish between calculus and cement. These results could be used for further devices to develop a method for feedback controlled calculus removal.

  18. Ultralow-Power Electronic Trapping of Nanoparticles with Sub-10 nm Gold Nanogap Electrodes.

    Science.gov (United States)

    Barik, Avijit; Chen, Xiaoshu; Oh, Sang-Hyun

    2016-10-12

    We demonstrate nanogap electrodes for rapid, parallel, and ultralow-power trapping of nanoparticles. Our device pushes the limit of dielectrophoresis by shrinking the separation between gold electrodes to sub-10 nm, thereby creating strong trapping forces at biases as low as the 100 mV ranges. Using high-throughput atomic layer lithography, we manufacture sub-10 nm gaps between 0.8 mm long gold electrodes and pattern them into individually addressable parallel electronic traps. Unlike pointlike junctions made by electron-beam lithography or larger micron-gap electrodes that are used for conventional dielectrophoresis, our sub-10 nm gold nanogap electrodes provide strong trapping forces over a mm-scale trapping zone. Importantly, our technology solves the key challenges associated with traditional dielectrophoresis experiments, such as high voltages that cause heat generation, bubble formation, and unwanted electrochemical reactions. The strongly enhanced fields around the nanogap induce particle-transport speed exceeding 10 μm/s and enable the trapping of 30 nm polystyrene nanoparticles using an ultralow bias of 200 mV. We also demonstrate rapid electronic trapping of quantum dots and nanodiamond particles on arrays of parallel traps. Our sub-10 nm gold nanogap electrodes can be combined with plasmonic sensors or nanophotonic circuitry, and their low-power electronic operation can potentially enable high-density integration on a chip as well as portable biosensing.

  19. Electron multibeam technology for mask and wafer writing at 0.1 nm address grid

    Science.gov (United States)

    Platzgummer, Elmar; Klein, Christof; Loeschner, Hans

    2013-07-01

    IMS Nanofabrication realized a 50 keV electron multibeam proof-of-concept (POC) tool confirming writing principles with 0.1 nm address grid and lithography performance capability. The POC system achieves the predicted 5 nm 1 sigma blur across the 82 μm×82 μm array of 512×512 (262,144) programmable 20 nm beams. 24-nm half pitch (HP) has been demonstrated and complex patterns have been written in scanning stripe exposure mode. The first production worthy system for the 11-nm HP mask node is scheduled for 2014 (Alpha), 2015 (Beta), and first-generation high-volume manufacturing multibeam mask writer (MBMW) tools in 2016. In these MBMW systems the max beam current through the column is 1 μA. The new architecture has also the potential for 1× mask (master template) writing. Substantial further developments are needed for maskless e-beam direct write (EBDW) applications as a beam current of >2 mA is needed to achieve 100 wafer per hour industrial targets for 300 mm wafer size. Necessary productivity enhancements of more than three orders of magnitude are only possible by shrinking the multibeam optics such that 50 to 100 subcolumns can be placed on the area of a 300 mm wafer and by clustering 10 to 20 multicolumn tools. An overview of current EBDW efforts is provided.

  20. Efficient 525 nm laser generation in single or double resonant cavity

    Science.gov (United States)

    Liu, Shilong; Han, Zhenhai; Liu, Shikai; Li, Yinhai; Zhou, Zhiyuan; Shi, Baosen

    2018-03-01

    This paper reports the results of a study into highly efficient sum frequency generation from 792 and 1556 nm wavelength light to 525 nm wavelength light using either a single or double resonant ring cavity based on a periodically poled potassium titanyl phosphate crystal (PPKTP). By optimizing the cavity's parameters, the maximum power achieved for the resultant 525 nm laser was 263 and 373 mW for the single and double resonant cavity, respectively. The corresponding quantum conversion efficiencies were 8 and 77% for converting 1556 nm photons to 525 nm photons with the single and double resonant cavity, respectively. The measured intra-cavity single pass conversion efficiency for both configurations was about 5%. The performances of the sum frequency generation in these two configurations was studied and compared in detail. This work will provide guidelines for optimizing the generation of sum frequency generated laser light for a variety of configurations. The high conversion efficiency achieved in this work will help pave the way for frequency up-conversion of non-classical quantum states, such as the squeezed vacuum and single photon states. The proposed green laser source will be used in our future experiments, which includes a plan to generate two-color entangled photon pairs and achieve the frequency down-conversion of single photons carrying orbital angular momentum.

  1. Photodissociation of the acetone cation at 355 nm using the velocity imaging technique

    Science.gov (United States)

    Jackson, William M.; Xu, Dadong

    2000-09-01

    Photodissociation of acetone cations, CH3COCH3+, at 355 nm has been studied by means of the ion velocity imaging technique. Acetone cations are produced via direct photoionization of a supersonic beam of acetone at 118 nm generated by frequency tripling the 355 nm laser. Only the acetyl cation, CH3CO+, could be detected as a dissociation product in the time-of-flight mass spectrometer. The acetyl ion signal depends upon the fifth power of the 355 nm laser energy, while the acetone ion signal depends upon the third power. This suggests that the fragment ion is produced via two-photon absorption of 355 nm photons by the acetone cation. The total translational energy distribution and angular distribution of acetyl cation were derived from the 2D images of CH3CO+ for the reaction CH3COCH3++2hν355nm→CH3CO++CH3*. The translational energy distribution suggests that methyl radicals are produced in two electronically excited states, the Rydberg 3s 1 2A1' and the valence 1 2A″ states. The anisotropy parameter β shows that the Rydberg state is formed via a perpendicular excitation and the valence state via a parallel transition.

  2. EUV patterning using CAR or MOX photoresist at low dose exposure for sub 36nm pitch

    Science.gov (United States)

    Thibaut, Sophie; Raley, Angélique; Lazarrino, Frederic; Mao, Ming; De Simone, Danilo; Piumi, Daniele; Barla, Kathy; Ko, Akiteru; Metz, Andrew; Kumar, Kaushik; Biolsi, Peter

    2018-04-01

    The semiconductor industry has been pushing the limits of scalability by combining 193nm immersion lithography with multi-patterning techniques for several years. Those integrations have been declined in a wide variety of options to lower their cost but retain their inherent variability and process complexity. EUV lithography offers a much desired path that allows for direct print of line and space at 36nm pitch and below and effectively addresses issues like cycle time, intra-level overlay and mask count costs associated with multi-patterning. However it also brings its own sets of challenges. One of the major barrier to high volume manufacturing implementation has been hitting the 250W power exposure required for adequate throughput [1]. Enabling patterning using a lower dose resist could help move us closer to the HVM throughput targets assuming required performance for roughness and pattern transfer can be met. As plasma etching is known to reduce line edge roughness on 193nm lithography printed features [2], we investigate in this paper the level of roughness that can be achieved on EUV photoresist exposed at a lower dose through etch process optimization into a typical back end of line film stack. We will study 16nm lines printed at 32 and 34nm pitch. MOX and CAR photoresist performance will be compared. We will review step by step etch chemistry development to reach adequate selectivity and roughness reduction to successfully pattern the target layer.

  3. Via patterning in the 7-nm node using immersion lithography and graphoepitaxy directed self-assembly

    Science.gov (United States)

    Doise, Jan; Bekaert, Joost; Chan, Boon Teik; Hori, Masafumi; Gronheid, Roel

    2017-04-01

    Insertion of a graphoepitaxy directed self-assembly process as a via patterning technology into integrated circuit fabrication is seriously considered for the 7-nm node and beyond. At these dimensions, a graphoepitaxy process using a cylindrical block copolymer that enables hole multiplication can alleviate costs by extending 193-nm immersion-based lithography and significantly reducing the number of masks that would be required per layer. To be considered for implementation, it needs to be proved that this approach can achieve the required pattern quality in terms of defects and variability using a representative, aperiodic design. The patterning of a via layer from an actual 7-nm node logic layout is demonstrated using immersion lithography and graphoepitaxy directed self-assembly in a fab-like environment. The performance of the process is characterized in detail on a full 300-mm wafer scale. The local variability in an edge placement error of the obtained patterns (4.0 nm 3σ for singlets) is in line with the recent results in the field and significantly less than of the prepattern (4.9 nm 3σ for singlets). In addition, it is expected that pattern quality can be further improved through an improved mask design and optical proximity correction. No major complications for insertion of the graphoepitaxy directed self-assembly into device manufacturing were observed.

  4. Continuous-wave single-frequency laser with dual wavelength at 1064 and 532 nm.

    Science.gov (United States)

    Zhang, Chenwei; Lu, Huadong; Yin, Qiwei; Su, Jing

    2014-10-01

    A continuous-wave high-power single-frequency laser with dual-wavelength output at 1064 and 532 nm is presented. The dependencies of the output power on the transmission of the output coupler and the phase-matching temperature of the LiB(3)O(5) (LBO) crystal are studied. An output coupler with transmission of 19% is used, and the temperature of LBO is controlled to the optimal phase-matching temperature of 422 K; measured maximal output powers of 33.7 W at 1064 nm and of 1.13 W at 532 nm are obtained with optical-optical conversion efficiency of 45.6%. The laser can be single-frequency operated stably and mode-hop-free, and the measured frequency drift is less than 15 MHz in 1 min. The measured Mx2 and My2 for the 1064 nm laser are 1.06 and 1.09, respectively. The measured Mx2 and My2 for the 532 nm laser are 1.12 and 1.11, respectively.

  5. Savannah River Site's Site Specific Plan

    International Nuclear Information System (INIS)

    1991-01-01

    This Site Specific Plan (SSP) has been prepared by the Savannah River Site (SRS) in order to show the Environmental Restoration and Waste Management activities that were identified during the preparation of the Department of Energy-Headquarters (DOE-HQ) Environmental Restoration and Waste Management Five-Year Plan (FYP) for FY 1992--1996. The SSP has been prepared in accordance with guidance received from DOE-HQ. DOE-SR is accountable to DOE-HQ for the implementation of this plan. The purpose of the SSP is to develop a baseline for policy, budget, and schedules for the DOE Environmental Restoration and Waste Management activities. The plan explains accomplishments since the Fiscal Year (FY) 1990 plan, demonstrates how present and future activities are prioritized, identifies currently funded activities and activities that are planned to be funded in the upcoming fiscal year, and describes future activities that SRS is considering

  6. SITE-94. Mineralogy of the Aespoe site

    International Nuclear Information System (INIS)

    Andersson, Karin

    1996-12-01

    The water composition has several impacts on the repository. It will influence the behaviour of the engineered materials (e.g. corrosion). It may also determine the possible solubility and speciation of released radionuclides. It also acts as a transport medium for the released elements. The groundwater composition and the potential development of the composition due to the presence of the repository as well as due to external variations is thus an important issue in a safety analysis. The development of the groundwater composition is strongly dependent on reactions with the minerals present in water bearing fractures. Here equilibrium chemistry may be of importance, but also reaction kinetics is important to the long-term behaviour. Within the SITE-94 project, a safety analysis is performed for the conditions at the Aespoe site. The mineralogy of the area has been evaluated from drill cores at various places at the site. In this report a recommendation for selection of mineralogy to be used in geochemical modelling of the repository is given. Calcite and iron containing minerals dominate the fracture filling mineralogy at the Aespoe site. Some typical fracture filling mineralogies may be identified in the fractures: epidote, chlorite, calcite, hematite, some illite/smectite + quartz, fluorite, pyrite and goethite. In addition to these a number of minor minerals are found in the fractures. Uncertainties in the fracture filling data may be due to problems when taking out the drill cores. Drilling water may remove important clay minerals and sealed fractures may be reopened mechanically and treated as water conducting fractures. The problem of determining the variability of the mineralogy along the flow paths also remains. This problem will never be solved when the investigation is performed by drilling investigation holes

  7. Preliminary Site Characterization Report, Rulsion Site, Colorado

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-08-01

    This report is a summary of environmental information gathered during a review of the documents pertaining to Project Rulison and interviews with personnel who worked on the project. Project Rulison was part of Operation Plowshare (a program designed to explore peaceful uses for nuclear devices). The project consisted of detonating a 43-kiloton nuclear device on September 10, 1969, in western Colorado to stimulate natural gas production. Following the detonation, a reentry well was drilled and several gas production tests were conducted. The reentry well was shut-in after the last gas production test and was held in standby condition until the general cleanup was undertaken in 1972. A final cleanup was conducted after the emplacement and testing wells were plugged in 1976. However, some surface radiologic contamination resulted from decontamination of the drilling equipment and fallout from the gas flaring during drilling operations. With the exception of the drilling effluent pond, all surface contamination at the Rulison Site was removed during the cleanup operations. All mudpits and other excavations were backfilled, and both upper and lower drilling pads were leveled and dressed. This report provides information regarding known or suspected areas of contamination, previous cleanup activities, analytical results, a review of the regulatory status, the site`s physical environment, and future recommendations for Project Ruhson. Based on this research, several potential areas of contamination have been identified. These include the drilling effluent pond and mudpits used during drilling operations. In addition, contamination could migrate in the gas horizon.

  8. Study of heat generation and cutting force according to minimization of grain size (500 nm to 180 nm) of WC ball endmill using FEM

    Science.gov (United States)

    Byeon, J. H.; Ahmed, F.; Ko, T. J.; lee, D. K.; Kim, J. S.

    2018-03-01

    As the industry develops, miniaturization and refinement of products are important issues. Precise machining is required for cutting, which is a typical method of machining a product. The factor determining the workability of the cutting process is the material of the tool. Tool materials include carbon tool steel, alloy tool steel, high-speed steel, cemented carbide, and ceramics. In the case of a carbide material, the smaller the particle size, the better the mechanical properties with higher hardness, strength and toughness. The specific heat, density, and thermal diffusivity are also changed through finer particle size of the material. In this study, finite element analysis was performed to investigate the change of heat generation and cutting power depending on the physical properties (specific heat, density, thermal diffusivity) of tool material. The thermal conductivity coefficient was obtained by measuring the thermal diffusivity, specific heat, and density of the material (180 nm) in which the particle size was finer and the particle material (0.05 μm) in the conventional size. The coefficient of thermal conductivity was calculated as 61.33 for 180nm class material and 46.13 for 0.05μm class material. As a result of finite element analysis using this value, the average temperature of exothermic heat of micronized particle material (180nm) was 532.75 °C and the temperature of existing material (0.05μm) was 572.75 °C. Cutting power was also compared but not significant. Therefore, if the thermal conductivity is increased through particle refinement, the surface power can be improved and the tool life can be prolonged by lowering the temperature generated in the tool during machining without giving a great influence to the cutting power.

  9. [The influence of pulsed low-intensity laser radiation of the red (635 nm) and infrared (904 nm) spectra on the human mesenchymal stem cells in vitro].

    Science.gov (United States)

    Moskvin, S V; Kliuchnikov, D Iu; Antipov, E V; Volchkov, S E; Kiseleva, O N

    2014-01-01

    Mesenchymal stem cells (MSC) have for a long time been an object of investigation with a view to elucidating the prospects for their application in clinical medicine and cosmetology. One of the approaches to the non-specific regulation of the activity of these cells at the stage of preliminary in vitro combination is the treatment with low-intensity laser radiation (LILR). The objective of the present study was to evaluate the possibility of using pulsed LILR of the infrared and red spectra for this purpose. We used the 4th passage adhesive MSC cultures based at the umbilical tissue of a donor who gave the informed consent to participate in the study. The source of illumination was a Lazmik-VLOK laser therapeutic apparatus (RU No RZN 2014/1410 dated 06.02.2014) with the matrix laser infrared radiation heads (wavelength 904 nm, light pulse length 108 ns, frequency 1500 Hz). The apparatus was operated either in the multi-frequency Lazmik regime [Moskvin S.V., 2014] with mean power density 0.05 and 0.14 mW/cm2 and the red spectrum (wavelength 635 nm, light pulse length 144 ns, frequency 1500 Hz) or in the multi-frequency Lazmik regime [Moskvin S.V., 2014] with mean power density 0.03 and 0.12. The exposition was 5 min in both regimes. The study has demonstrated that neither the morphological structure nor the viability of mesenchymal stem cells changed under the influence of energy and time parameters used in experiments. The number of cells was shown to slightly increase in comparison with control. The most pronounced effect was documented after illumination with pulse infrared (904 nm) LILR in the multi-frequency Lazmik regime. The maximum effect was observed during a period between days 1 and 3 of cultivation.

  10. Synthesis of sub-10 nm VO{sub 2} nanoparticles films with plasma-treated glass slides by aqueous sol–gel method

    Energy Technology Data Exchange (ETDEWEB)

    Lan, Shi-Di [Department of Materials Science and Engineering, National Taiwan University of Science and Technology, 43, Sec. 4, Keelung Rd, Taipei 106, Taiwan, ROC (China); Cheng, Chih-Chia [Graduate Institute of Applied Science and Technology, National Taiwan University of Science and Technology, Taipei, Taiwan (China); Huang, Chi-Hsien [Department of Materials Engineering, Ming Chi University of Technology, 84 Gungjuan Road, Taishan Dist., New Taipei City 24301, Taiwan (China); Chen, Jem-Kun, E-mail: jkchen@mail.ntust.edu.tw [Department of Materials Science and Engineering, National Taiwan University of Science and Technology, 43, Sec. 4, Keelung Rd, Taipei 106, Taiwan, ROC (China)

    2015-12-01

    Highlights: • Sub-10 nm VO{sub 2} nanoparticles (VNPs) are synthesized on a plasma-treated glass. • Glass slides generate negative charges sites after plasma treatment to attract VO{sub 2}{sup +}. • Doping tungsten with 1 wt% in VNPs did not change particle size significantly. • The particle size of VNP can be tuned by the density of negative charge sites. • Sub-10 nm structured VO{sub 2} particle films exhibited high visible transmittance. - Abstract: This paper describes an aqueous sol–gel synthesis of thermochromic thin films consisted of vanadium dioxide nanoparticles (VNPs) on glass slides. The glass slides were treated by argon/oxygen plasma to generate dispersedly negative charge sites on the surface to attract VO{sub 2}{sup +} from a sol–gel solution. After heat treatment in a low-pressure carbon monoxide/carbon dioxide (CO/CO{sub 2}) atmosphere, the VNPs could be generated in sub-10 nm of particle size on the surface. Various levels of doping were achieved by adding small quantities of a water-soluble tungsten compound to the sol; however, the particle size increased slightly with the tungsten doping levels. The change in electrical conductivity with temperature for VNP films were measured and compared to VO{sub 2} crystalline films. VNP films exhibited the lower transition temperature of the semiconductor to metal phase change; at a doping level of 4 wt% the transition temperature was measured at 32.2 ± 1.2 and 24.1 ± 1.2 °C for the VO{sub 2} and VNP films, respectively. The VNP films showed excellent visible transparency and a large change in transmittance at near-infrared (NIR) wavelengths before and after the metal–insulator phase transition (MIT). The current method is a landmark in the development of nanostructured material toward applications in energy-saving smart windows.

  11. Synthesis of sub-10 nm VO2 nanoparticles films with plasma-treated glass slides by aqueous sol–gel method

    International Nuclear Information System (INIS)

    Lan, Shi-Di; Cheng, Chih-Chia; Huang, Chi-Hsien; Chen, Jem-Kun

    2015-01-01

    Highlights: • Sub-10 nm VO 2 nanoparticles (VNPs) are synthesized on a plasma-treated glass. • Glass slides generate negative charges sites after plasma treatment to attract VO 2 + . • Doping tungsten with 1 wt% in VNPs did not change particle size significantly. • The particle size of VNP can be tuned by the density of negative charge sites. • Sub-10 nm structured VO 2 particle films exhibited high visible transmittance. - Abstract: This paper describes an aqueous sol–gel synthesis of thermochromic thin films consisted of vanadium dioxide nanoparticles (VNPs) on glass slides. The glass slides were treated by argon/oxygen plasma to generate dispersedly negative charge sites on the surface to attract VO 2 + from a sol–gel solution. After heat treatment in a low-pressure carbon monoxide/carbon dioxide (CO/CO 2 ) atmosphere, the VNPs could be generated in sub-10 nm of particle size on the surface. Various levels of doping were achieved by adding small quantities of a water-soluble tungsten compound to the sol; however, the particle size increased slightly with the tungsten doping levels. The change in electrical conductivity with temperature for VNP films were measured and compared to VO 2 crystalline films. VNP films exhibited the lower transition temperature of the semiconductor to metal phase change; at a doping level of 4 wt% the transition temperature was measured at 32.2 ± 1.2 and 24.1 ± 1.2 °C for the VO 2 and VNP films, respectively. The VNP films showed excellent visible transparency and a large change in transmittance at near-infrared (NIR) wavelengths before and after the metal–insulator phase transition (MIT). The current method is a landmark in the development of nanostructured material toward applications in energy-saving smart windows.

  12. 980nm laser for difficult-to-treat basal cell carcinoma

    Science.gov (United States)

    Derjabo, A. D.; Cema, I.; Lihacova, I.; Derjabo, L.

    2013-06-01

    Begin basal cell carcinoma (BCC) is most common skin cancer over the world. There are around 20 modalities for BCC treatment. Laser surgery is uncommon option. We demonstrate our long term follow up results. Aim: To evaluate long term efficacy of a 980nm diode laser for the difficult-to-treat basal cell carcinoma. Materials and Methods: 167 patients with 173 basal cell carcinoma on the nose were treated with a 980 nm diode laser from May 1999 till May 2005 at Latvian Oncology center. All tumors were morphologically confirmed. 156 patients were followed for more than 5 years. Results: The lowest recurrence rate was observed in cases of superficial BCC, diameterConclusions: 980 nm diode laser is useful tool in dermatology with high long term efficacy, good acceptance by the patients and good cosmetics results.

  13. Continuous-wave ceramic Nd:YAG laser at 1123 nm

    International Nuclear Information System (INIS)

    Zhang, S S; Wang, Q P; Zhang, X Y; Cong, Z H; Fan, S Z; Liu, Z J; Sun, W J

    2009-01-01

    Ceramic Nd:YAG (cNd:YAG) materials are employed to generate 1123-nm laser. A fiber-coupled continuous-wave (CW) 808-nm diode laser is used as the pumping source. With an incident diode power of 26.1 W, a CW output power of up to 10.8 W is obtained with a 10-mm-long ceramic Nd:YAG rod (1.0 at.%-Nd-doped). The conversion efficiency from diode power to 1123-nm laser power is 41.4%. The laser performance of another 10-mm-long cNd:YAG rod with a Nd-doping concentration of 0.6 at.% is studied as a comparison

  14. Optical track width measurements below 100 nm using artificial neural networks

    Science.gov (United States)

    Smith, R. J.; See, C. W.; Somekh, M. G.; Yacoot, A.; Choi, E.

    2005-12-01

    This paper discusses the feasibility of using artificial neural networks (ANNs), together with a high precision scanning optical profiler, to measure very fine track widths that are considerably below the conventional diffraction limit of a conventional optical microscope. The ANN is trained using optical profiles obtained from tracks of known widths, the network is then assessed by applying it to test profiles. The optical profiler is an ultra-stable common path scanning interferometer, which provides extremely precise surface measurements. Preliminary results, obtained with a 0.3 NA objective lens and a laser wavelength of 633 nm, show that the system is capable of measuring a 50 nm track width, with a standard deviation less than 4 nm.

  15. Line width measurement below 60 nm using an optical interferometer and artificial neural network

    Science.gov (United States)

    See, Chung W.; Smith, Richard J.; Somekh, Michael G.; Yacoot, Andrew

    2007-03-01

    We have recently described a technique for optical line-width measurements. The system currently is capable of measuring line-width down to 60 nm with a precision of 2 nm, and potentially should be able to measure down to 10nm. The system consists of an ultra-stable interferometer and artificial neural networks (ANNs). The former is used to generate optical profiles which are input to the ANNs. The outputs of the ANNs are the desired sample parameters. Different types of samples have been tested with equally impressive results. In this paper we will discuss the factors that are essential to extend the application of the technique. Two of the factors are signal conditioning and sample classification. Methods, including principal component analysis, that are capable of performing these tasks will be considered.

  16. EUV lithography for 30nm half pitch and beyond: exploring resolution, sensitivity, and LWR tradeoffs

    Science.gov (United States)

    Putna, E. Steve; Younkin, Todd R.; Chandhok, Manish; Frasure, Kent

    2009-03-01

    The International Technology Roadmap for Semiconductors (ITRS) denotes Extreme Ultraviolet (EUV) lithography as a leading technology option for realizing the 32nm half-pitch node and beyond. Readiness of EUV materials is currently one high risk area according to assessments made at the 2008 EUVL Symposium. The main development issue regarding EUV resist has been how to simultaneously achieve high sensitivity, high resolution, and low line width roughness (LWR). This paper describes the strategy and current status of EUV resist development at Intel Corporation. Data is presented utilizing Intel's Micro-Exposure Tool (MET) examining the feasibility of establishing a resist process that simultaneously exhibits <=30nm half-pitch (HP) L/S resolution at <=10mJ/cm2 with <=4nm LWR.

  17. EUV lithography for 22nm half pitch and beyond: exploring resolution, LWR, and sensitivity tradeoffs

    Science.gov (United States)

    Putna, E. Steve; Younkin, Todd R.; Leeson, Michael; Caudillo, Roman; Bacuita, Terence; Shah, Uday; Chandhok, Manish

    2011-04-01

    The International Technology Roadmap for Semiconductors (ITRS) denotes Extreme Ultraviolet (EUV) lithography as a leading technology option for realizing the 22nm half pitch node and beyond. According to recent assessments made at the 2010 EUVL Symposium, the readiness of EUV materials remains one of the top risk items for EUV adoption. The main development issue regarding EUV resists has been how to simultaneously achieve high resolution, high sensitivity, and low line width roughness (LWR). This paper describes our strategy, the current status of EUV materials, and the integrated post-development LWR reduction efforts made at Intel Corporation. Data collected utilizing Intel's Micro- Exposure Tool (MET) is presented in order to examine the feasibility of establishing a resist process that simultaneously exhibits <=22nm half-pitch (HP) L/S resolution at <=11.3mJ/cm2 with <=3nm LWR.

  18. In vivo 808 nm image-guided photodynamic therapy based on an upconversion theranostic nanoplatform

    Science.gov (United States)

    Liu, Xiaomin; Que, Ivo; Kong, Xianggui; Zhang, Youlin; Tu, Langping; Chang, Yulei; Wang, Tong Tong; Chan, Alan; Löwik, Clemens W. G. M.; Zhang, Hong

    2015-09-01

    A new strategy for efficient in vivo image-guided photodynamic therapy (PDT) has been demonstrated utilizing a ligand-exchange constructed upconversion-C60 nanophotosensitizer. This theranostic platform is superior to the currently reported nanophotosensitizers in (i) directly bonding photosensitizer C60 to the surface of upconversion nanoparticles (UCNPs) by a smart ligand-exchange strategy, which greatly shortened the energy transfer distance and enhanced the 1O2 production, resulting in the improvement of the therapeutic effect; (ii) realizing in vivo NIR 808 nm image-guided PDT with both excitation (980 nm) and emission (808 nm) light falling in the biological window of tissues, which minimized auto-fluorescence, reduced light scatting and improved the imaging contrast and depth, and thus guaranteed noninvasive diagnostic accuracy. In vivo and ex vivo tests demonstrated its favorable bio-distribution, tumor-selectivity and high therapeutic efficacy. Owing to the effective ligand exchange strategy and the excellent intrinsic photophysical properties of C60, 1O2 production yield was improved, suggesting that a low 980 nm irradiation dosage (351 J cm-2) and a short treatment time (15 min) were sufficient to perform NIR (980 nm) to NIR (808 nm) image-guided PDT. Our work enriches the understanding of UCNP-based PDT nanophotosensitizers and highlights their potential use in future NIR image-guided noninvasive deep cancer therapy.A new strategy for efficient in vivo image-guided photodynamic therapy (PDT) has been demonstrated utilizing a ligand-exchange constructed upconversion-C60 nanophotosensitizer. This theranostic platform is superior to the currently reported nanophotosensitizers in (i) directly bonding photosensitizer C60 to the surface of upconversion nanoparticles (UCNPs) by a smart ligand-exchange strategy, which greatly shortened the energy transfer distance and enhanced the 1O2 production, resulting in the improvement of the therapeutic effect; (ii

  19. Sub-10 nm colloidal lithography for circuit-integrated spin-photo-electronic devices

    Directory of Open Access Journals (Sweden)

    Adrian Iovan

    2012-12-01

    Full Text Available Patterning of materials at sub-10 nm dimensions is at the forefront of nanotechnology and employs techniques of various complexity, efficiency, areal scale, and cost. Colloid-based patterning is known to be capable of producing individual sub-10 nm objects. However, ordered, large-area nano-arrays, fully integrated into photonic or electronic devices have remained a challenging task. In this work, we extend the practice of colloidal lithography to producing large-area sub-10 nm point-contact arrays and demonstrate their circuit integration into spin-photo-electronic devices. The reported nanofabrication method should have broad application areas in nanotechnology as it allows ballistic-injection devices, even for metallic materials with relatively short characteristic relaxation lengths.

  20. Performance of diethylene glycol-based particle counters in the sub-3 nm size range

    CERN Document Server

    Wimmer, D; Franchin, A; Kangasluoma, J; Kreissl, F; Kürten, A; Kupc, A; Metzger, A; Mikkilä, J; Petäjä, J; Riccobono, F; Vanhanen, J; Kulmala, M; Curtius, J

    2013-01-01

    When studying new particle formation, the uncertainty in determining the "true" nucleation rate is considerably reduced when using condensation particle counters (CPCs) capable of measuring concentrations of aerosol particles at sizes close to or even at the critical cluster size (1–2 nm). Recently, CPCs able to reliably detect particles below 2 nm in size and even close to 1 nm became available. Using these instruments, the corrections needed for calculating nucleation rates are substantially reduced compared to scaling the observed formation rate to the nucleation rate at the critical cluster size. However, this improved instrumentation requires a careful characterization of their cut-off size and the shape of the detection efficiency curve because relatively small shifts in the cut-off size can translate into larger relative errors when measuring particles close to the cut-off size. Here we describe the development of two continuous-flow CPCs using diethylene glycol (DEG) as the working fluid. The desig...

  1. Optimum source/drain overlap design for 16 nm high-k/metal gate MOSFETs

    International Nuclear Information System (INIS)

    Jang, Junyong; Lim, Towoo; Kim, Youngmin

    2009-01-01

    We explore a source/drain (S/D) design for a 16 nm MOSFET utilizing a replacement process for a high-k gate dielectric and metal gate electrode integration. Using TCAD simulation, a trade-off study between series resistance and overlap capacitance is carried out for a high-k dielectric surrounding gate structure, which results from the replacement process. An optimum S/D overlap to gate for the high-k surrounding gate structure is found to be different from the conventional gate structure, i.e. 0∼1 nm underlap is preferred for the surround high-k gate structure while 1∼2 nm overlap for the conventional gate one

  2. Supercontinuum generation from 437 to 2850 nm in a tapered fluorotellurite microstructured fiber

    Science.gov (United States)

    Wang, F.; Jia, Z. X.; Yao, C. F.; Wang, S. B.; Hu, M. L.; Wu, C. F.; Ohishi, Y.; Qin, W. P.; Qin, G. S.

    2016-12-01

    We demonstrated supercontinuum (SC) generation in a tapered fluorotellurite microstructured fiber (MF) with a sub-micrometer core diameter. Fluorotellurite MFs based on TeO2-BaF2-Y2O3 glasses were fabricated by using a rod-in-tube method and a tapered fluorotellurite MF with a minimum core diameter of ~0.65 µm was prepared by employing a tapering system. A 1560 nm femtosecond fiber laser was used as the pumping source. With increasing the peak power of the launched pump laser to ~11 kW, SC light expanding from 437 to 2850 nm was generated in the tapered fluorotellurite MF. In addition, relatively strong blue-shifted dispersive wave at ~489 nm was also observed from the tapered fluorotellurite MF.

  3. Evaluation of portable Raman spectrometer with 1064 nm excitation for geological and forensic applications.

    Science.gov (United States)

    Vítek, Petr; Ali, Esam M A; Edwards, Howell G M; Jehlička, Jan; Cox, Rick; Page, Kristian

    2012-02-01

    The development of miniaturized Raman instrumentation is in demand for applications relevant to forensic, pharmaceutical and art analyses, as well as geosciences, and planetary exploration. In this study we report on evaluation of a portable dispersive Raman spectrometer equipped with 1064 nm laser excitation. Selected samples from geological, geobiological and forensic areas of interest have been studied from which the advantages, disadvantages and the analytical potential of the instrument are assessed based on a comparison with bench instrumentation and other portable Raman spectrometers using 785 nm excitation. It is demonstrated that the instrument operating with 1064 nm excitation has potential for expanding the number and types of samples that can be measured by miniaturized Raman spectroscopy without interfering fluorescence background emission. It includes inorganic and organic minerals, biomolecules within living lichen and endolithic cyanobacteria as well as drugs of abuse and explosives. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. NM-Net Gigabit-based Implementation on Core Network Facilities and Network Design Hierarchy

    International Nuclear Information System (INIS)

    Raja Murzaferi Raja Moktar; Mohd Fauzi Haris; Siti Nurbahyah Hamdan

    2011-01-01

    Nuclear Malaysia computing network or NM the main backbone of internet working on operational staffs. Main network operating center or NOC is situated in Block 15 and linkup via fiber cabling to adjacent main network blocks (18, 29, 11 connections. Pre 2009 infrastructure; together to form the core networking switch. of the core network infrastructure were limited by the up link between core switches that is the Pair (UTP) Category 6 Cable. Furthermore, majority of the networking infrastructure throughout the agency were mainly built with Fast Ethernet Based specifications to date. With current research and operational tasks highly dependent on IT infrastructure that is being enabled through NM-Net, the performance NM-Net implementing gigabit-based networking system achieve optimal performance of internet networking services in the agency thus catalyze initiative. (author)

  5. High efficiency single frequency 355 nm all-solid-state UV laser

    International Nuclear Information System (INIS)

    Xie, Xiaobing; Wei, Daikang; Ma, Xiuhua; Li, Shiguang; Liu, Jiqiao; Zhu, Xiaolei; Chen, Weibiao

    2016-01-01

    A novel conductively cooled high energy single-frequency 355 nm all-solid-state UV laser is presented based on sum-frequency mixing technique. In this system, a pulsed seeder laser at 1064 nm wavelength, modulated by an AOM, is directly amplified by the cascaded multi-stage hybrid laser amplifiers, and two LBO crystals are used for the SHG and SFG, finally a maximum UV pulse energy of 226 mJ at 355 nm wavelength is achieved with frequency-tripled conversion efficiency as high as 55%, the pulse width is around 12.2 ns at the repetition frequency of 30 Hz. The beam quality factor M 2 of the output UV laser is measured to be 2.54 and 2.98 respectively in two orthogonal directions. (paper)

  6. Generation of 25-TW Femtosecond Laser Pulses at 515 nm with Extremely High Temporal Contrast

    Directory of Open Access Journals (Sweden)

    Marco Hornung

    2015-12-01

    Full Text Available We report on the frequency doubling of femtosecond laser pulses at 1030 nm center wavelength generated from the fully diode-pumped laser system POLARIS. The newly generated pulses at a center wavelength of 515 nm have a pulse energy of 3 J with a pulse duration of 120 fs. On the basis of initially ultra-high contrast seed pulses we expect a temporal intensity contrast better 10 17 200 ps before the peak of the main pulse. We analyzed the temporal intensity contrast from milliseconds to femtoseconds with a dynamic range covering more than 20 orders of magnitude. The pulses were focussed with a f/2-focussing parabola resulting in a peak intensity exceeding 10 20 W / cm 2 . The peak power and intensity are to the best of our knowledge the highest values for 515 nm-laser-pulses achieved so far.

  7. Efficient laser-diode end-pumped Nd:GGG lasers at 1054 and 1067 nm.

    Science.gov (United States)

    Xu, Bin; Xu, Huiying; Cai, Zhiping; Camy, P; Doualan, J L; Moncorgé, R

    2014-10-10

    Efficient and compact laser-diode end-pumped Nd:GGG simultaneous multiwavelength continuous-wave lasers at ∼1059, ∼1060 and ∼1062  nm were first demonstrated in a free-running 30 mm plano-concave laser cavity. The maximum output power was up to 3.92 W with a slope efficiency of about 53.6% with respect to the absorbed pump power. By inserting a 0.1 mm optical glass plate acting as a Fabry-Pérot etalon, a single-wavelength laser at ∼1067  nm with a maximum output power of 1.95 W and a slope efficiency of 28.5% can be obtained. Multiwavelength lasers, including those at ∼1054 or ∼1067  nm, were also achievable by suitably tilting the glass etalon. These simultaneous multiwavelength lasers provide a potential source for terahertz wave generation.

  8. EUV actinic defect inspection and defect printability at the sub-32 nm half pitch

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Sungmin; Kearney, Patrick; Wurm, Stefan; Goodwin, Frank; Han, Hakseung; Goldberg, Kenneth; Mochi, Iacopp; Gullikson, Eric M.

    2009-08-01

    Extreme ultraviolet (EUV) mask blanks with embedded phase defects were inspected with a reticle actinic inspection tool (AIT) and the Lasertec M7360. The Lasertec M7360, operated at SEMA TECH's Mask Blank Development Center (MBDC) in Albany, NY, has a sensitivity to multilayer defects down to 40-45 nm, which is not likely sufficient for mask blank development below the 32 nm half-pitch node. Phase defect printability was simulated to calculate the required defect sensitivity for a next generation blank inspection tool to support reticle development for the sub-32 nm half-pitch technology node. Defect mitigation technology is proposed to take advantage of mask blanks with some defects. This technology will reduce the cost of ownership of EUV mask blanks. This paper will also discuss the kind of infrastructure that will be required for the development and mass production stages.

  9. Site-Specific Innovation

    DEFF Research Database (Denmark)

    Reeh, Henrik; Hemmersam, Peter

    2015-01-01

    Currently, cities across the Northern European region are actively redeveloping their former industrial harbours. Indeed, harbours areas are essential in the long-term transition from industrial to information and experience societies; harbours are becoming sites for new businesses and residences...... question is how innovation may contribute to urban life and site-specific qualities....

  10. Criminal Justice Web Sites.

    Science.gov (United States)

    Dodge, Timothy

    1998-01-01

    Evaluates 15 criminal justice Web sites that have been selected according to the following criteria: authority, currency, purpose, objectivity, and potential usefulness to researchers. The sites provide narrative and statistical information concerning crime, law enforcement, the judicial system, and corrections. Searching techniques are also…

  11. The site selection process

    International Nuclear Information System (INIS)

    Kittel, J.H.

    1989-01-01

    One of the most arduous tasks associated with the management of radioactive wastes is the siting of new disposal facilities. Experience has shown that the performance of the disposal facility during and after disposal operations is critically dependent on the characteristics of the site itself. The site selection process consists of defining needs and objectives, identifying geographic regions of interest, screening and selecting candidate sites, collecting data on the candidate sites, and finally selecting the preferred site. Before the site selection procedures can be implemented, however, a formal legal system must be in place that defines broad objectives and, most importantly, clearly establishes responsibilities and accompanying authorities for the decision-making steps in the procedure. Site selection authorities should make every effort to develop trust and credibility with the public, local officials, and the news media. The responsibilities of supporting agencies must also be spelled out. Finally, a stable funding arrangement must be established so that activities such as data collection can proceed without interruption. Several examples, both international and within the US, are given

  12. A 1470-nm laser combined with foam sclerotherapy in day surgery: a better choice for lower limb varicose veins.

    Science.gov (United States)

    Zhang, Xing; Wang, Xin; Gao, Cheng; Qin, Jinbao; Zhao, Haiguang; Li, Weimin; Lu, Xinwu

    2018-04-23

    Day surgery is being more and more adopted by clinicians. Higher wavelength lasers give patients better experience than lower wavelength lasers, which makes it more suitable for day surgery. This study compares the short- and mid-term efficacy, postoperative morbidity, and patient satisfaction of "1470-nm endovenous laser ablation (EVLA) combining foam sclerotherapy in day surgery" with "810-nm EVLA with high ligation combining foam sclerotherapy in hospital surgery" on great saphenous vein (GSV) insufficiency postoperatively. A single-institution historical cohort study of 194 patients was performed in Shanghai Ninth People's Hospital, China. Ninety-seven patients received 1470-nm EVLA combining foam sclerotherapy in day surgery ("1470-nm group"), and 97 patients received 810-nm EVLA with high ligation combining foam sclerotherapy in hospital surgery recommended by guidelines ("810-nm group"). No significant difference was found between the 1470-nm group and the 810-nm group in terms of GSV occlusion rate (both 100%), complication rate, and recurrence rate (8.2 vs. 11.3%) during the period of 1-12 months after surgery. Serious complications in the 1470-nm group and 810-nm group were 0 and 1.0%. Minor complications in the 1470-nm group and 810-nm group were ecchymosis at 20.6 and 18.6%, edema at 69.1 and 63.9%, and paresthesia around ankle at 0 and 3.1%, respectively. Advantage of the 1470-nm group over the 810-nm group was statistically significant considering the patient perioperative comfort and economic cost. Treatment of 1470-nm EVLA combining foam sclerotherapy in day surgery has similar efficacy as the 810-nm EVLA with high ligation combining foam sclerotherapy in hospital surgery in GSV insufficiency and is more comfortable with less incision, hospitalization procedure, and medical costs. It may be a new option for patients who are afraid or unable to be hospitalized.

  13. Advanced 65 nm CMOS devices fabricated using ultra-low energy plasma doping

    International Nuclear Information System (INIS)

    Walther, S.; Lenoble, D.; Lallement, F.; Grouillet, A.; Erokhin, Y.; Singh, V.; Testoni, A.

    2005-01-01

    For leading edge CMOS and DRAM technologies, plasma doping (PLAD) offers several unique advantages over conventional beamline implantation. For ultra-low energy source and drain extensions (SDE), source drain contact and high dose poly doping implants PLAD delivers 2-5x higher throughput compared to beamline implanters. In this work we demonstrate process performance and process integration benefits enabled by plasma doping for advanced 65 nm CMOS devices. Specifically, p + /n ultra-shallow junctions formed with BF 3 plasma doping have superior X j /R s characteristics to beamline implants and yield up to 30% lower R s for 20 nm X j while using standard spike anneal with ramp-up rate of 75 deg. C/s. These results indicate that PLAD could extend applicability of standard spike anneal by at least one technology node past 65 nm. A CMOS split lot has been run to investigate process integration advantages unique to plasma doping and to determine CMOS device characteristics. Device data measured on 65 nm transistors fabricated with offset spacers indicate that devices with SDE formed by plasma doping have superior V t roll-off characteristics arguably due to improved lateral gate-overlap of PLAD SDE junctions. Furthermore, offset spacers could be eliminated in 65 nm devices with PLAD SDE implants while still achieving V t roll-off and I on -I off performance at least equivalent to control devices with offset spacers and SDE formed by beamline implantation. Thus, another advantage of PLAD is simplified 65 nm CMOS manufacturing process flow due to elimination of offset spacers. Finally, we present process transfer from beamline implants to PLAD for several applications, including SDE and gate poly doping with very high productivity

  14. Simultaneous response of NmF2 and GPS-TEC to storm events at Ilorin

    Science.gov (United States)

    Joshua, B. W.; Adeniyi, J. O.; Oladipo, O. A.; Doherty, P. H.; Adimula, I. A.; Olawepo, A. O.; Adebiyi, S. J.

    2018-06-01

    A comparative study of both TEC and NmF2 variations during quiet and disturbed conditions has been investigated using simultaneous measurements from dual frequency Global Positioning System (GPS) receiver and a DPS-4 Digisonde co-located at Ilorin (Geog. Lat. 8.50°N, Long. 4.50°E, dip. - 7.9°). The results of the quiet time variations of the two parameters show some similarities as well as differences in their structures. The values of both parameters generally increase during the sunrise period attaining a peak around the noon and then decaying towards the night time. The onset time of the sunrise growth is observed to be earlier in TEC than in NmF2. The rate of decay of TEC was observed to be faster than that of the NmF2 in most cases. Also, the noon 'bite-outs', leading to the formation of pre-noon and post-noon peaks, are prominent in the NmF2 structure and was hardly noticed in TEC. Results of the variations of both TEC and NmF2 during the 5 April, 10 May and 3 August 2010 geomagnetic storm events showed a simultaneous deviations of both parameters from the quiet time behavior. The magnitude of the deviations is however most pronounced in NmF2 structure than in TEC. We also found that the enhancement observed in the two parameters during the storm events generally corresponds to decrease in hmF2.

  15. Dose and batch-dependent hepatobiliary toxicity of 10 nm silver nanoparticles

    Directory of Open Access Journals (Sweden)

    Marcella De Maglie

    2015-07-01

    Full Text Available Silver nanoparticles (AgNPs are widely used because of their antimicrobial properties in medical devices and in a variety of consumer products. The extensive use of AgNPs raises concerns about their potential toxicity, although it is still difficult to draw definite conclusions about their toxicity based on published data. Our preliminary studies performed to compare the effect of the AgNPs size (10-40-100 nm on toxicity, demonstrated that the smallest AgNPs determine the most severe toxicological effects. In order to best investigate the impact of physicochemical characteristics of 10 nm AgNPs on toxicity, we compare three different batches of 10 nm AgNPs slightly different in size distribution (Batch A: 8.8±1.7 nm; Batch B: 9.4±1.7 nm; Batch C: 10.0±1.8 nm. Mice were intravenously treated with two doses (5 and 10 mg/kg of the 3 AgNPs. 24 hours after the treatment, mice were euthanized and underwent complete necropsy. Tissues were collected for histopathological examination and total silver content was determined in tissues by inductively coupled plasma mass spectrometry (ICP-MS. All batches induced severe hepatobiliary lesions, i.e. marked hepatocellular necrosis and massive hemorrhage of the gall bladder. The toxicity was dose-dependent and interestingly, the toxic effects were more severe in mice treated with batches A and B that contained smaller AgNPs. Since the total silver mass concentration was similar, the observed batch-dependent toxicity suggest that even subtle differences in size may contribute to relevant changes in the toxicological outcomes, confirming the fundamental involvement of physicochemical features with respect to toxicity.

  16. Efficacy of antimicrobial 405 nm blue-light for inactivation of airborne bacteria

    Science.gov (United States)

    Dougall, Laura R.; Anderson, John G.; Timoshkin, Igor V.; MacGregor, Scott J.; Maclean, Michelle

    2018-02-01

    Airborne transmission of infectious organisms is a considerable concern within the healthcare environment. A number of novel methods for `whole room' decontamination, including antimicrobial 405 nm blue light, are being developed. To date, research has focused on its effects against surface-deposited contamination; however, it is important to also establish its efficacy against airborne bacteria. This study demonstrates evidence of the dose-response kinetics of airborne bacterial contamination when exposed to 405 nm light and compares bacterial susceptibility when exposed in three different media: air, liquid and surfaces. Bacterial aerosols of Staphylococcus epidermidis, generated using a 6-Jet Collison nebulizer, were introduced into an aerosol suspension chamber. Aerosolized bacteria were exposed to increasing doses of 405 nm light, and air samples were extracted from the chamber using a BioSampler liquid impinger, with viability analysed using pour-plate culture. Results have demonstrated successful aerosol inactivation, with a 99.1% reduction achieved with a 30 minute exposure to high irradiance (22 mWcm-2) 405 nm light (P=0.001). Comparison to liquid and surface exposures proved bacteria to be 3-4 times more susceptible to 405 nm light inactivation when in aerosol form. Overall, results have provided fundamental evidence of the susceptibility of bacterial aerosols to antimicrobial 405 nm light treatment, which offers benefits in terms of increased safety for human exposure, and eradication of microbes regardless of antibiotic resistance. Such benefits provide advantages for a number of applications including `whole room' environmental decontamination, in which reducing levels of airborne bacteria should reduce the number of infections arising from airborne contamination.

  17. The application of phase grating to CLM technology for the sub-65nm node optical lithography

    Science.gov (United States)

    Yoon, Gi-Sung; Kim, Sung-Hyuck; Park, Ji-Soong; Choi, Sun-Young; Jeon, Chan-Uk; Shin, In-Kyun; Choi, Sung-Woon; Han, Woo-Sung

    2005-06-01

    As a promising technology for sub-65nm node optical lithography, CLM(Chrome-Less Mask) technology among RETs(Resolution Enhancement Techniques) for low k1 has been researched worldwide in recent years. CLM has several advantages, such as relatively simple manufacturing process and competitive performance compared to phase-edge PSM's. For the low-k1 lithography, we have researched CLM technique as a good solution especially for sub-65nm node. As a step for developing the sub-65nm node optical lithography, we have applied CLM technology in 80nm-node lithography with mesa and trench method. From the analysis of the CLM technology in the 80nm lithography, we found that there is the optimal shutter size for best performance in the technique, the increment of wafer ADI CD varied with pattern's pitch, and a limitation in patterning various shapes and size by OPC dead-zone - OPC dead-zone in CLM technique is the specific region of shutter size that dose not make the wafer CD increased more than a specific size. And also small patterns are easily broken, while fabricating the CLM mask in mesa method. Generally, trench method has better optical performance than mesa. These issues have so far restricted the application of CLM technology to a small field. We approached these issues with 3-D topographic simulation tool and found that the issues could be overcome by applying phase grating in trench-type CLM. With the simulation data, we made some test masks which had many kinds of patterns with many different conditions and analyzed their performance through AIMS fab 193 and exposure on wafer. Finally, we have developed the CLM technology which is free of OPC dead-zone and pattern broken in fabrication process. Therefore, we can apply the CLM technique into sub-65nm node optical lithography including logic devices.

  18. Laboratory Measurements of the 940, 1130, and 1370 nm Water Vapor Absorption Band Profiles

    Science.gov (United States)

    Giver, Lawrence P.; Gore, Warren J.; Pilewskie, P.; Freedman, R. S.; Chackerian, C., Jr.; Varanasi, P.

    2001-01-01

    We have used the solar spectral flux radiometer (SSFR) flight instrument with the Ames 25 meter base-path White cell to obtain about 20 moderate resolution (8 nm) pure water vapor spectra from 650 to 1650 nm, with absorbing paths from 806 to 1506 meters and pressures up to 14 torr. We also obtained a set at 806 meters with several different air-broadening pressures. Model simulations were made for the 940, 1130, and 1370 nm absorption bands for some of these laboratory conditions using the Rothman, et al HITRAN-2000 linelist. This new compilation of HITRAN includes new intensity measurements for the 940 nm region. We compared simulations for our spectra of this band using HITRAN-2000 with simulations using the prior HITRAN-1996. The simulations of the 1130 nm band show about 10% less absorption than we measured. There is some evidence that the total intensity of this band is about 38% stronger than the sum of the HITRAN line intensities in this region. In our laboratory conditions the absorption depends approximately on the square root of the intensity. Thus, our measurements agree that the band is stronger than tabulated in HITRAN, but by about 20%, substantially less than the published value. Significant differences have been shown between Doppler-limited resolution spectra of the 1370 nm band obtained at the Pacific Northwest National Laboratory and HITRAN simulations. Additional new intensity measurements in this region are continuing to be made. We expect the simulations of our SSFR lab data of this band will show the relative importance of improving the HITRAN line intensities of this band for atmospheric measurements.

  19. [Study on genetic instability of nm23H1 gene in Chinese with original gallbladder tumor].

    Science.gov (United States)

    Lu, Hai Ying; Zhang, Guo Qiang; Li, Ji Cheng

    2006-06-01

    The aim of this study was to examine the microsatellite instability (MSI) and loss of heterozygosity (LOH) of locus D17S396 on chromosome 17 and their influence on the expression of nm23H1 in gallbladder tumors, which may provide experimental basis for the tumor occurrence and metastasis. Techniques such as DNA extraction from formalin-fixed paraffin-embedded tissues, polymerase chain reaction-single strand conformation polymorphism (PCR-SSCP), ordinary silver stain were used to study MSI and LOH of locus D17S396. Envision immunohistochemistry and Leica-Qwin computer imaging techniques were used to assess the expression of gene nm23H1. In our experiment, the frequency of genetic instability of malignant gallbladder tumors was 42.55%, which was higher than that of gallbladder adenomas, while there were no genetic instability occurred in chronic cholecystitis tissue. The frequency of LOH seemed higher with the deteriorism of gallbladder tumor. Among 47 gallbladder carcinomas, the frequency of LOH and MSI were different between different differentiation cases (P gallbladder carcinoma, gallbladder adenoma and chronic cholecystitis tissue were different (P gallbladder carcinomas, the positive frequency of nm23H1 protein in LOH positive group was lower than that of LOH negative group (P gallbladder tumor. Both MSI and LOH of nm23H1 gene controlled the development of gallbladder tumor independently in different paths. MSI may be an early stage molecule marker of gallbladder carcinoma. LOH may be molecule marker for the deteriorism of gallbladder tissue, which could inhibit the expression of nm23H1 in local tissue of gallbladder carcinoma and endow it with high aggressive and poor prognosis. Increasing the amount of nm23H1 protein expression could effectively restrain gallbladder carcinoma metastasis and improve prognosis of patients.

  20. Siting nuclear power plants

    International Nuclear Information System (INIS)

    Yellin, J.; Joskow, P.L.

    1980-01-01

    The first edition of this journal is devoted to the policies and problems of siting nuclear power plants and the question of how far commercial reactors should be placed from urban areas. The article is divided into four major siting issues: policies, risk evaluation, accident consequences, and economic and physical constraints. One concern is how to treat currently operating reactors and those under construction that were established under less-stringent criteria if siting is to be used as a way to limit the consequences of accidents. Mehanical cost-benefit analyses are not as appropriate as the systematic use of empirical observations in assessing the values involved. Stricter siting rules are justified because (1) opposition because of safety is growing: (2) remote siting will make the industry more stable; (3) the conflict is eliminated between regulatory policies and the probability basis for nuclear insurance; and (4) joint ownership of utilities and power-pooling are increasing. 227 references, 7 tables

  1. Site directed recombination

    Science.gov (United States)

    Jurka, Jerzy W.

    1997-01-01

    Enhanced homologous recombination is obtained by employing a consensus sequence which has been found to be associated with integration of repeat sequences, such as Alu and ID. The consensus sequence or sequence having a single transition mutation determines one site of a double break which allows for high efficiency of integration at the site. By introducing single or double stranded DNA having the consensus sequence flanking region joined to a sequence of interest, one can reproducibly direct integration of the sequence of interest at one or a limited number of sites. In this way, specific sites can be identified and homologous recombination achieved at the site by employing a second flanking sequence associated with a sequence proximal to the 3'-nick.

  2. Site decommissioning management plan

    International Nuclear Information System (INIS)

    Fauver, D.N.; Austin, J.H.; Johnson, T.C.; Weber, M.F.; Cardile, F.P.; Martin, D.E.; Caniano, R.J.; Kinneman, J.D.

    1993-10-01

    The Nuclear Regulatory Commission (NRC) staff has identified 48 sites contaminated with radioactive material that require special attention to ensure timely decommissioning. While none of these sites represent an immediate threat to public health and safety they have contamination that exceeds existing NRC criteria for unrestricted use. All of these sites require some degree of remediation, and several involve regulatory issues that must be addressed by the Commission before they can be released for unrestricted use and the applicable licenses terminated. This report contains the NRC staff's strategy for addressing the technical, legal, and policy issues affecting the timely decommissioning of the 48 sites and describes the status of decommissioning activities at the sites

  3. Site decommissioning management plan

    Energy Technology Data Exchange (ETDEWEB)

    Fauver, D.N.; Austin, J.H.; Johnson, T.C.; Weber, M.F.; Cardile, F.P.; Martin, D.E.; Caniano, R.J.; Kinneman, J.D.

    1993-10-01

    The Nuclear Regulatory Commission (NRC) staff has identified 48 sites contaminated with radioactive material that require special attention to ensure timely decommissioning. While none of these sites represent an immediate threat to public health and safety they have contamination that exceeds existing NRC criteria for unrestricted use. All of these sites require some degree of remediation, and several involve regulatory issues that must be addressed by the Commission before they can be released for unrestricted use and the applicable licenses terminated. This report contains the NRC staff`s strategy for addressing the technical, legal, and policy issues affecting the timely decommissioning of the 48 sites and describes the status of decommissioning activities at the sites.

  4. The development needs of nuclear medicine (NM) in Finland in 1980-84

    International Nuclear Information System (INIS)

    Vauramo, E.; Ahonen, A.; Korkola, O.; Liewendahl, K.; Laensimies, E.; Nyyssoenen, O.; Pietilae, P.; Tervo-Pellikka, R.; Wendelin, H.

    1980-01-01

    In autumn 1978, a task group was set up by the Finnish Hospital League to investigate the development needs of nuclear medicine (NM) in Finland. Clinical chemistry, clinical physiology, diagnostic radiology and hospital physics were represented on the working group. The National Board of Health, the Institute of Radiation Protection and the Finnish Hospital League were also represented. The views of other fields were considered by asking for statements from hospitals, research institutes and medical associations. This report deals with NM procedures on patients. Sample studies (in vitro) belong to the clinical laboratory and they were dealt with only to a minor extent. (orig.) [de

  5. Wavelength beam combining of a 980-nm tapered diode laser bar in an external cavity

    DEFF Research Database (Denmark)

    Vijayakumar, Deepak; Jensen, Ole Bjarlin; Thestrup Nielsen, Birgitte

    2010-01-01

    solution for preserving the beam quality of the bar in the range of that of a single emitter and at the same time, enabling the power scaling. We report spectral beam combining applied to a 12 emitter tapered laser bar at 980 nm. The external cavity has been designed for a wavelength separation of 4.0 nm......High power diode lasers are used in a large number of applications. A limiting factor for more widespread use of broad area lasers is the poor beam quality. Gain guided tapered diode lasers are ideal candidates for industrial applications that demands watt level output power with good beam quality...

  6. Coherent Detection for 1550 nm, 5 Gbit/s VCSEL Based 40 km Bidirectional PON Transmission

    DEFF Research Database (Denmark)

    Jensen, Jesper Bevensee; Rodes Lopez, Roberto; Zibar, Darko

    2011-01-01

    Coherent detection of directly modulated 1550nm VCSELs in 5Gbit/s bidirectional 40km SSMF PON-links is presented. Receiver sensitivity of –37.3dBm after transmission is achieved with 30dB system margin, corresponding to 1:1024 passive powersplitting.......Coherent detection of directly modulated 1550nm VCSELs in 5Gbit/s bidirectional 40km SSMF PON-links is presented. Receiver sensitivity of –37.3dBm after transmission is achieved with 30dB system margin, corresponding to 1:1024 passive powersplitting....

  7. 885-nm laser diode array pumped ceramic Nd:YAG master oscillator power amplifier system

    Science.gov (United States)

    Yu, Anthony W.; Li, Steven X.; Stephen, Mark A.; Seas, Antonios; Troupaki, Elisavet; Vasilyev, Aleksey; Conley, Heather; Filemyr, Tim; Kirchner, Cynthia; Rosanova, Alberto

    2010-04-01

    The objective of this effort is to develop more reliable, higher efficiency diode pumped Nd:YAG laser systems for space applications by leveraging technology investments from the DoD and other commercial industries. Our goal is to design, build, test and demonstrate the effectiveness of combining 885 nm laser pump diodes and the use of ceramic Nd:YAG for future flight missions. The significant reduction in thermal loading on the gain medium by the use of 885 nm pump lasers will improve system efficiency.

  8. Red laser-diode pumped 806 nm Tm3+: ZBLAN fibre laser

    Science.gov (United States)

    Juárez-Hernández, M.; Mejía, E. B.

    2017-06-01

    A Tm3+-doped fluorozirconate (ZBLAN) fibre laser operating CW at 806 nm when diode-pumped at 687 nm is described for the first time. This device is based on the 3F4  →  3H6 transition, and is suitable for first telecom window and sensing applications. A slope efficiency of 50.3% and low threshold pump-power of 11.6 mW were obtained. Maximum output power of 15 mW for 40 mW coupled pump was achieved.

  9. Reduction of single-walled carbon nanotube diameter to sub-nm via feedstock

    Energy Technology Data Exchange (ETDEWEB)

    Thurakitseree, T.; Zhao, Pei; Chiashi, Shohei; Maruyama, Shigeo [Department of Mechanical Engineering, University of Tokyo (Japan); Kramberger, Christian [Faculty of Physics, University of Vienna (Austria); Einarsson, Erik [Department of Mechanical Engineering, University of Tokyo (Japan); Global Center of Excellence for Mechanical Systems Innovation, University of Tokyo (Japan)

    2012-12-15

    Vertically aligned single-walled carbon nanotube arrays were synthesized from dip-coated binary Co/Mo catalyst by no-flow chemical vapor deposition (CVD) from either pure ethanol or acetonitrile as carbon feedstock. By changing to acetonitrile the mean diameter was reduced from 2.1 nm to less than 1.0 nm despite using identically prepared catalyst. The demonstrated diameter control on flat substrates is a versatile approach towards the direct synthesis of tailored single-walled carbon nanotubes. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  10. Detection of OH on photolysis of styrene oxide at 193 nm in gas phase

    Science.gov (United States)

    Kumar, Awadhesh; SenGupta, Sumana; Pushpa, K. K.; Naik, P. D.; Bajaj, P. N.

    2006-10-01

    Photodissociation of styrene oxide at 193 nm in gas phase generates OH, as detected by laser-induced fluorescence technique. Under similar conditions, OH was not observed from ethylene and propylene oxides, primarily because of their low absorption cross-sections at 193 nm. Mechanism of OH formation involves first opening of the three-membered ring from the ground electronic state via cleavage of either of two C sbnd O bonds, followed by isomerization to enolic forms of phenylacetaldehyde and acetophenone, and finally scission of the C sbnd OH bond of enols. Ab initio molecular orbital calculations support the proposed mechanism.

  11. Negative-tone imaging with EUV exposure toward 13nm hp

    Science.gov (United States)

    Tsubaki, Hideaki; Nihashi, Wataru; Tsuchihashi, Toru; Yamamoto, Kei; Goto, Takahiro

    2016-03-01

    Negative-tone imaging (NTI) with EUV exposure has major advantages with respect to line-width roughness (LWR) and resolution due in part to polymer swelling and favorable dissolution mechanics. In NTI process, both resist and organic solvents play important roles in determining lithography performances. The present study describes novel chemically amplified resist materials based on NTI technology with EUV using a specific organic solvents. Lithographic performances of NTI process were described in this paper under exposures using ASML NXE:3300 EUV scanner at imec. It is emphasized that 14 nm hp was nicely resolved under exposure dose of 37 mJ/cm2 without any bridge and collapse, which are attributed to the low swelling character of NTI process. Although 13 nm hp resolution was potentially obtained, a pattern collapse still restricts its resolution in case coating resist film thickness is 40 nm. Dark mask limitation due mainly to mask defectivity issue makes NTI with EUV favorable approach for printing block mask to produce logic circuit. A good resolution of CD-X 21 nm/CD-Y 32 nm was obtained for block mask pattern using NTI with usable process window and dose of 49 mJ/cm2. Minimum resolution now reaches CD-X 17 nm / CD-Y 23 nm for the block. A 21 nm block mask resolution was not affected by exposure dose and explored toward low dose down to 18 mJ/cm2 by reducing quencher loading. In addition, there was a negligible amount of increase in LCDU for isolated dot pattern when decreasing exposure dose from 66 mJ/cm2 to 24 mJ/cm2. On the other hand, there appeared tradeoff relationship between LCDU and dose for dense dot pattern, indicating photon-shot noise restriction, but strong dependency on patterning features. Design to improve acid generation efficiency was described based on acid generation mechanism in traditional chemically amplified materials which contains photo-acid generator (PAG) and polymer. Conventional EUV absorber comprises of organic compounds is

  12. Microstructure and Mechanical Properties of ASTM A743 CA6NM Steel Welded by FCAW Process

    OpenAIRE

    Silva, Rafael de Paula; Faria, Maria Ismenia Sodero Toledo; Almeida, Luiz Fernando Cursino Briet de; Nunes, Carlos Angelo; Vieira, Décio; Borges Júnior, Wanderlei

    2017-01-01

    CA6NM steel is widely used in the manufacture of hydraulic turbines metallic parts, due to its resistance to corrosion and cavitation damage, combined with good weldability and fatigue properties. However, welding of this type of steel is complex and to ensure a minimum residual stress after welding it is necessary perform a post welding heat treatment (PWHT) of the part. This study aims to analyze the effect of a PWHT on the microstructure and mechanical properties of CA6NM steel weld joint ...

  13. Absorption coefficients for water vapor at 193 nm from 300 to 1073 K

    Science.gov (United States)

    Kessler, W. J.; Carleton, K. L.; Marinelli, W. J.

    1993-01-01

    Measurements of the water absorption coefficient at 193 nm from 300 to 1073 K are reported. The measurements were made using broadband VUV radiation and a monochromator-based detection system. The water vapor was generated by a saturator and metered into a flowing, 99 cm absorption cell via a water vapor mass flow meter. The 193 nm absorption coefficient measurements are compared to room temperature and high temperature shock tube measurements with good agreement. The absorption can be parameterized by a nu3 vibrational mode reaction coordinate and the thermal population of the nu3 mode.

  14. Response of Cloud Condensation Nuclei (> 50 nm) to changes in ion-nucleation

    DEFF Research Database (Denmark)

    Svensmark, Henrik; Enghoff, Martin B.; Pedersen, Jens Olaf Pepke

    2012-01-01

    In experiments where ultraviolet light produces aerosols from trace amounts of ozone, sulphur dioxide, and water vapour, the number of additional small particles produced by ionization by gamma sources all grow up to diameters larger than 50 nm, appropriate for cloud condensation nuclei. This res......In experiments where ultraviolet light produces aerosols from trace amounts of ozone, sulphur dioxide, and water vapour, the number of additional small particles produced by ionization by gamma sources all grow up to diameters larger than 50 nm, appropriate for cloud condensation nuclei...... finding points to a process not included in current theoretical models, possibly an ion-induced formation of sulphuric acid in small clusters....

  15. Design for manufacturability from 1D to 4D for 90-22 nm technology nodes

    CERN Document Server

    Balasinski, Artur

    2013-01-01

    This book explains integrated circuit design for manufacturability (DfM) at the product level (packaging, applications) and applies engineering DfM principles to the latest standards of product development at 22 nm technology nodes.  It is a valuable guide for layout designers, packaging engineers and quality engineers, covering DfM development from 1D to 4D, involving IC design flow setup, best practices, links to manufacturing and product definition, for process technologies down to 22 nm node, and product families including memories, logic, system-on-chip and system-in-package.

  16. 375-nm ultraviolet-laser based non-line-of-sight underwater optical communication

    KAUST Repository

    Sun, Xiaobin

    2018-05-04

    For circumventing the alignment requirement of line-of-sight (LOS) underwater wireless optical communication (UWOC), we demonstrated a non-line-of-sight (NLOS) UWOC link adequately enhanced using ultraviolet (UV) 375-nm laser. Path loss was chosen as a figure-of-merit for link performance in this investigation, which considers the effects of geometries, water turbidity, and transmission wavelength. The experiments suggest that path loss decreases with smaller azimuth angles, higher water turbidity, and shorter wavelength due in part to enhanced scattering utilizing 375-nm radiation. We highlighted that it is feasible to extend the current findings for long distance NLOS UWOC link in turbid water, such as harbor water.

  17. Modeling of filamentation damage induced in silica by 351-nm laser pulses

    International Nuclear Information System (INIS)

    Milam, D.; Manes, K.R.; Williams, W.H.

    1996-01-01

    A major risk factor that must be considered in design of the National Ignition Facility is the possibility for catastrophic self-focusing of the 351-nm beam in the silica optical components that are in the final section of the laser. Proposed designs for the laser are analyzed by the beam-propagation code PROP92. A 351-nm self-focusing experiment, induction of tracking damage, was done to provide data for validation of this code. The measured self-focusing lengths were correctly predicted by the code

  18. Design, synthesis, and characterization of fluorine-free PAGs for 193-nm lithography

    Science.gov (United States)

    Liu, Sen; Glodde, Martin; Varanasi, Pushkara R.

    2010-04-01

    Photoacid generators (PAGs) are a key component in chemically amplified resists used in photolithography. Perfluorooctanesulfonates (PFOS) and other perfluoroalkylsulfonates (PFAS) have been well adopted as PAGs in 193 nm photoresist. Recently, concerns have been raised about their environmental impact due to their chemical persistency, bioaccumulation and toxicity. It is a general interest to find environmentally benign PAGs that are free of fluorine atoms. Here we describe the design, synthesis and characterization of a series of novel fluorine-free onium salts as PAGs for 193 nm photoresists. These PAGs demonstrated desirable physical and lithography properties when compared with PFAS-based PAGs for both dry and immersion exposures.

  19. Phase-shifted Bragg grating inscription in PMMA microstructured POF using 248 nm UV radiation

    DEFF Research Database (Denmark)

    Pereira, L.; Pospori, A.; Antunes, Paulo

    2017-01-01

    In this work we experimentally validate and characterize the first phase-shifted polymer optical fiber Bragg gratings (PS-POFBGs) produced using a single pulse from a 248 nm krypton fluoride laser. A single-mode poly (methyl methacrylate) optical fiber with a core doped with benzyl dimethyl ketal...... for photosensitivity improvement was used. A uniform phase mask customized for 850 nm grating inscription was used to inscribe these Bragg structures. The phase shift defect was created directly during the grating inscription process by placing a narrow blocking aperture in the center of the UV beam. The produced high...

  20. Gain optimization and saturation of the Xe III 109 nm auger laser

    International Nuclear Information System (INIS)

    Macklin, J.J.; Sher, M.H.; Barty, C.P.J.; King, D.A.; Yin, G.Y.; Harris, S.E.; Young, J.F.

    1988-01-01

    The authors describe the construction and operation of a 109 nm, photoionization-pumped, single-pass laser in Xe III. The laser is pumped by soft x-rays emitted from a laser-produced plasma in a traveling-wave geometry. Using a 3.5 J, 300 psec, 1064 nm laser pump pulse, they measure a small-signal gain coefficient of 4.4 cm -1 and a total small signal gain of exp(40). The laser is fully saturated and produces an output energy of 20 μJ in a beam with 10 mrad divergence

  1. Two-photon-excited fluorescence spectroscopy of atomic fluorine at 170 nm

    Science.gov (United States)

    Herring, G. C.; Dyer, Mark J.; Jusinski, Leonard E.; Bischel, William K.

    1988-01-01

    Two-photon-excited fluorescence spectroscopy of atomic fluorine is reported. A doubled dye laser at 286-nm is Raman shifted in H2 to 170 nm (sixth anti-Stokes order) to excite ground-state 2P(0)J fluorine atoms to the 2D(0)J level. The fluorine atoms are detected by one of two methods: observing the fluorescence decay to the 2PJ level or observing F(+) production through the absorption of an additional photon by the excited atoms. Relative two-photon absorption cross sections to and the radiative lifetimes of the 2D(0)J states are measured.

  2. Measurement of the quantum efficiency of TMAE and TEA from threshold to 120 nm

    International Nuclear Information System (INIS)

    Holroyd, R.A.; Preses, J.M.; Woody, C.L.; Johnson, R.A.

    1986-01-01

    Several existing and planned high energy physics experiments incorporate detectors which use either TMAE (tetrakis-dimethylaminoethylene) or TEA (triethylamine) as their photosensitive agent. Understanding the operation of these devices requires knowledge of the absolute photoionization quantum efficiencies and absorption lengths of TMAE and TEA. In an experiment performed at the National Synchrotron Light source at Brookhaven National Laboratory, we have measured these parameters from 120 nm to 280 nm. The quantum efficiencies were normalized to the known photoionization yields of benzene and cis-2-butene. The results of these measurements and details of the experiment are presented in this paper

  3. High resolution emission spectra of H2 and D2 near 80 nm

    International Nuclear Information System (INIS)

    Larzilliere, M.; Roncin, J.-Y.; Launay, F.

    1980-01-01

    A few lines have been observed in the far ultraviolet emission spectrum of molecular hydrogen and deuterium. They are assigned to transitions from levels of the 3pπD 1 PIsub(u)sup(-) state, lying above the dissociation limit into H(ls) + H(n=2), near 84.5 nm, and, for some of them, above the first ionization limit near 80.4 nm, the lower state being X 1 Σsub(g)sup(+) (v''=1). This is in fair agreement with measured predissociation and preionization yields. Accurate line position measurements lead to molecular constants in very good agreement with theoretical calculations

  4. Nearly penalty-free, less than 4 ps supercontinuum Gbit/s pulse generation over 1535-1560 nm

    Science.gov (United States)

    Morioka, T.; Kawanishi, S.; Mori, K.; Saruwatari, M.

    1994-05-01

    Nearly penalty-free less than 4ps supercontinuum WDM pulses are generated at 6.3 Gbit/s over 1535-1560 nm for the first time using a 200 nm superbroadened supercontinuum in an optical fibre pumped by 1.7 W, 3.3 ps, 1542 nm short pulses from an Er(3+)-doped fibre ring laser.

  5. Tunable high-power narrow-spectrum external-cavity diode laser based on tapered amplifier at 668 nm

    DEFF Research Database (Denmark)

    Chi, Mingjun; Erbert, G.; Sumpf, B.

    2010-01-01

    A 668 nm tunable high-power narrow-spectrum diode laser system based on a tapered semiconductor optical amplifier in external cavity is demonstrated. The laser system is tunable from 659 to 675 nm. As high as 1.38 W output power is obtained at 668.35 nm. The emission spectral bandwidth is less than...

  6. Effects of blue diode laser (445 nm) and LED (430-480 nm) radiant heat treatments on dental glass ionomer restoratives

    Science.gov (United States)

    Dionysopoulos, Dimitrios; Tolidis, Kosmas; Strakas, Dimitrios; Gerasimou, Paris; Sfeikos, Thrasyvoulos; Gutknecht, Norbert

    2018-02-01

    The purpose of this in vitro study was to evaluate the effect of two radiant heat treatments on water sorption, solubility and surface roughness of three conventional glass ionomer cements by using a blue diode laser (445 nm) and a light emitting diode (LED) unit (430-480 nm). Thirty disk-shaped specimens were prepared for each tested GIC (Equia Fil, Ketac Universal Aplicap and Riva Self Cure). The experimental groups (n = 10) of the study were as follows: Group 1 was the control group, in Group 2 the specimens were irradiated for 60 s at the top surface using a LED light-curing unit and in Group 3 the specimens were irradiated for 60 s at the top surface using a blue light diode laser. Statistical analysis was performed using one-way ANOVA and Tukey post hoc tests at a level of significance of a = 0.05. Radiant heat treatments with both laser and LED devices significantly decreased water sorption and solubility (p tested GICs. Blue diode laser treatment was seemed to be more effective compared to LED treatment for some of the tested materials. There were no changes in surface roughness of the GICs after the treatments (p > 0.05). Among the tested materials there were differences in water sorption and solubility (p 0.05). The use of the blue diode laser for this radiant heat treatment was harmless for the surface of the tested GICs and may be advantageous for the longevity of their restorations.

  7. Raman ratios on the repair of grafted surgical bone defects irradiated or not with laser (λ780 nm) or LED (λ850 nm).

    Science.gov (United States)

    Pinheiro, Antonio Luiz B; Soares, Luiz Guilherme P; Marques, Aparecida Maria C; Aciole, Jouber Mateus S; de Souza, Renato Aparecido; Silveira, Landulfo

    2014-09-05

    This work aimed to assess biochemical changes associated to mineralization and remodeling of bone defects filled with Hydroxyapatite+Beta-Beta-tricalcium phosphate irradiated or not with 2 light sources. Ratios of intensities, band position and bandwidth of selected Raman peaks of collagen and apatites were used. Sixty male Wistar rats were divided into 6 groups subdivided into 2 subgroups (15th and 30th days). A standard surgical defect was created on one femur of each animal. In 3 groups the defects were filled with blood clot (Clot, Clot+Laser and Clot+LED groups) and in the remaining 3 groups the defects were filled with biomaterial (Biomaterial, Biomaterial+Laser and Biomaterial+LED groups). When indicated, the defects were irradiated with either Laser (λ780 nm, 70 mW, Φ∼0.4 cm(2)) or LED (λ850±10 nm, 150 mW, Φ∼0.5 cm(2)), 20 J/cm(2) each session, at 48 h intervals/2 weeks (140 J/cm(2) treatment). Following sacrifice, bone fragments were analyzed by Raman spectroscopy. Statistical analysis (ANOVA General Linear Model, pRaman ratios of selected protein matrix and phosphate and carbonate HA indicated that the use of biphasic synthetic micro-granular HA+Beta-TCP graft improved the repair of bone defects, associated or not with Laser or LED light, because of the increasing deposition of HA. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Synthesis and characterization of metastable, 20 nm-sized Pna2{sub 1}-LiCoPO{sub 4} nanospheres

    Energy Technology Data Exchange (ETDEWEB)

    Ludwig, Jennifer [Technical University of Munich, Department of Chemistry, Synthesis and Characterization of Innovative Materials, Lichtenbergstr. 4, 85747 Garching (Germany); Nordlund, Dennis [Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, 2575 Sand Hill Rd, Menlo Park, CA 94025 (United States); Doeff, Marca M. [Lawrence Berkeley National Laboratory, Environmental Energy Technologies Division, 1 Cyclotron Rd, Berkeley, CA 94720 (United States); Nilges, Tom, E-mail: tom.nilges@lrz.tum.de [Technical University of Munich, Department of Chemistry, Synthesis and Characterization of Innovative Materials, Lichtenbergstr. 4, 85747 Garching (Germany)

    2017-04-15

    The majority of research activities on LiCoPO{sub 4} are focused on the phospho-olivine (space group Pnma), which is a promising high-voltage cathode material for Li-ion batteries. In contrast, comparably little is known about its metastable Pna2{sub 1} modification. Herein, we present a comprehensive study on the structure–property relationships of 15–20 nm Pna2{sub 1}-LiCoPO{sub 4} nanospheres prepared by a simple microwave-assisted solvothermal process. Unlike previous reports, the results indicate that the compound is non-stoichiometric and shows cation-mixing with Co ions on the Li sites, which provides an explanation for the poor electrochemical performance. Co L{sub 2,3}-edge X-ray absorption spectroscopic data confirm the local tetrahedral symmetry of Co{sup 2+}. Comprehensive studies on the thermal stability using thermogravimetric analysis, differential scanning calorimetry, and in situ powder X-ray diffraction show an exothermic phase transition to olivine Pnma-LiCoPO{sub 4} at 527 °C. The influence of the atmosphere and the particle size on the thermal stability is also investigated. - Graphical abstract: Blue nano-sized Pna2{sub 1}-LiCoPO{sub 4,} featuring tetrahedrally-coordinated Co{sup 2+}, was synthesized in a rapid one-step microwave-assisted solvothermal process. The phase relation between this metastable and the stable polymorph was analyzed and electrochemical properties are discussed. - Highlights: • Preparation of uniform 15–20 nm nanospheres of metastable Pna2{sub 1}-LiCoPO{sub 4} polymorph. • Structure redetermination shows cation-mixing (Co blocking Li sites). • In situ investigation of phase transformation to olivine Pnma-LiCoPO{sub 4} at 527 °C. • Pna2{sub 1}-LiCoPO{sub 4} reemerges as a stable high-temperature phase above 800 °C. • X-ray absorption spectroscopy confirms local tetrahedral symmetry (T{sub d} Co{sup 2+}).

  9. 1994 Site environmental report

    International Nuclear Information System (INIS)

    1995-07-01

    The Fernald site is a Department of Energy (DOE)-owned facility that produced high-quality uranium metals for military defense for nearly 40 years. DOE suspended production at the site in 1989 and formally ended production in 1991. Although production activities have ceased, the site continues to examine the air and liquid pathways as possible routes through which pollutants from past operations and current remedial activities may leave the site. The Site Environmental Report (SER) is prepared annually in accordance with DOE Order 5400.1, General Environmental Protection Program. This 1994 SER provides the general public as well as scientists and engineers with the results from the site's ongoing Environmental Monitoring Program. Also included in this report is information concerning the site's progress toward achieving full compliance with requirements set forth by DOE, U.S. Environmental Protection Agency (USEPA), and Ohio EPA (OEPA). For some readers, the highlights provided in this Executive Summary may provide sufficient information. Many readers, however, may wish to read more detailed descriptions of the information than those which are presented here. All information presented in this summary is discussed more fully in the main body of this report

  10. SITE-94. Radionuclide solubilities for SITE-94

    Energy Technology Data Exchange (ETDEWEB)

    Arthur, R.; Apted, M. [QuantiSci, Denver, CO (United States)

    1996-12-01

    In this report, solubility constraints are evaluated on radioelement source-term concentrations supporting the SITE-94 performance assessment. Solubility models are based on heterogeneous-equilibrium, mass- and charge-balance constraints incorporated into the EQ3/6 geochemical software package, which is used to calculate the aqueous speciation behavior and solubilities of U, Th, Pu, Np, Am, Ni, Ra, Se, Sn, Sr, Tc and Zr in site groundwaters and near-field solutions. The chemical evolution of the near field is approximated using EQ3/6 in terms of limiting conditions at equilibrium, or steady state, in three closed systems representing fully saturated bentonite, Fe{sup o} corrosion products of the canister, and spent fuel. The calculations consider both low-temperature (15 deg C) and high-temperature (80 deg C) conditions in the near field, and the existence of either reducing or strongly oxidizing conditions in each of the bentonite, canister, and spent-fuel barriers. Heterogeneities in site characteristics are evaluated through consideration of a range of initial groundwaters and their interactions with engineered barriers. Aqueous speciation models for many radioelements are constrained by thermodynamic data that are estimated with varying degrees of accuracy. An important question, however, is how accurate do these models need to be for purposes of estimating source-term concentrations? For example, it is unrealistic to expect a high degree of accuracy in speciation models if such models predict solubilities that are below the analytical detection limit for a given radioelement. From a practical standpoint, such models are irrelevant if calculated solubilities cannot be tested by direct comparison to experimental data. In the absence of models that are both accurate and relevant for conditions of interest, the detection limit could define a pragmatic upper limit on radioelement solubility 56 refs, 25 tabs, 10 figs

  11. SITE-94. Radionuclide solubilities for SITE-94

    International Nuclear Information System (INIS)

    Arthur, R.; Apted, M.

    1996-12-01

    In this report, solubility constraints are evaluated on radioelement source-term concentrations supporting the SITE-94 performance assessment. Solubility models are based on heterogeneous-equilibrium, mass- and charge-balance constraints incorporated into the EQ3/6 geochemical software package, which is used to calculate the aqueous speciation behavior and solubilities of U, Th, Pu, Np, Am, Ni, Ra, Se, Sn, Sr, Tc and Zr in site groundwaters and near-field solutions. The chemical evolution of the near field is approximated using EQ3/6 in terms of limiting conditions at equilibrium, or steady state, in three closed systems representing fully saturated bentonite, Fe o corrosion products of the canister, and spent fuel. The calculations consider both low-temperature (15 deg C) and high-temperature (80 deg C) conditions in the near field, and the existence of either reducing or strongly oxidizing conditions in each of the bentonite, canister, and spent-fuel barriers. Heterogeneities in site characteristics are evaluated through consideration of a range of initial groundwaters and their interactions with engineered barriers. Aqueous speciation models for many radioelements are constrained by thermodynamic data that are estimated with varying degrees of accuracy. An important question, however, is how accurate do these models need to be for purposes of estimating source-term concentrations? For example, it is unrealistic to expect a high degree of accuracy in speciation models if such models predict solubilities that are below the analytical detection limit for a given radioelement. From a practical standpoint, such models are irrelevant if calculated solubilities cannot be tested by direct comparison to experimental data. In the absence of models that are both accurate and relevant for conditions of interest, the detection limit could define a pragmatic upper limit on radioelement solubility

  12. The dynamics of femtosecond pulsed laser removal of 20 nm Ni films from an interface

    Energy Technology Data Exchange (ETDEWEB)

    Schrider, Keegan J.; Yalisove, Steven M. [Department of Materials Science and Engineering, University of Michigan, Ann Arbor, Michigan 48109 (United States); Torralva, Ben [Department of Atmospheric, Oceanic, and Space Sciences, University of Michigan, Ann Arbor, Michigan 48109 (United States)

    2015-09-21

    The dynamics of femtosecond laser removal of 20 nm Ni films on glass substrates was studied using time-resolved pump-probe microscopy. 20 nm thin films exhibit removal at two distinct threshold fluences, removal of the top 7 nm of Ni above 0.14 J/cm{sup 2}, and removal of the entire 20 nm film above 0.36 J/cm{sup 2}. Previous work shows the top 7 nm is removed through liquid spallation, after irradiation the Ni melts and rapidly expands leading to tensile stress and cavitation within the Ni film. This work shows that above 0.36 J/cm{sup 2} the 20 nm film is removed in two distinct layers, 7 nm and 13 nm thick. The top 7 nm layer reaches a speed 500% faster than the bottom 13 nm layer at the same absorbed fluence, 500–2000 m/s and 300–700 m/s in the fluence ranges studied. Significantly different velocities for the top 7 nm layer and bottom 13 nm layer indicate removal from an interface occurs by a different physical mechanism. The method of measuring film displacement from the development of Newton's rings was refined so it could be shown that the 13 nm layer separates from the substrate within 70 ps and accelerates to its final velocity within several hundred picoseconds. We propose that removal of the bottom 13 nm is consistent with heterogeneous nucleation and growth of vapor at the Ni-glass interface, but that the rapid separation and acceleration of the 13 nm layer from the Ni-glass interface requires consideration of exotic phases of Ni after excitation.

  13. Site Environmental Report, 1993

    International Nuclear Information System (INIS)

    1994-06-01

    The Site Environmental Report (SER) is prepared annually in accordance with DOE Order 5400.1, ''General Environmental Protection Program.'' This 1993 SER provides the general public as well as scientists and engineers with the results from the site's ongoing Environmental Monitoring Program. Also included in this report is information concerning the site's progress toward achieving full compliance with requirements set forth by DOE, US Environmental Protection Agency (USEPA), and Ohio EPA (OEPA). For some readers, the highlights provided in the Executive Summary may provide sufficient information. Many readers, however, may wish to read more detailed descriptions of the information than those which are presented here

  14. Spin wave eigenmodes in single and coupled sub-150 nm rectangular permalloy dots

    Energy Technology Data Exchange (ETDEWEB)

    Carlotti, G., E-mail: giovanni.carlotti@fisica.unipg.it; Madami, M. [Dipartimento di Fisica e Geologia, Università di Perugia, Perugia (Italy); Tacchi, S. [Istituto Officina dei Materiali del CNR (CNR-IOM), Dipartimento di Fisica e Geologia, Perugia (Italy); Gubbiotti, G.; Dey, H.; Csaba, G.; Porod, W. [Center for Nano Science and Technology, Department of Electrical Engineering, University of Notre Dame, Notre Dame, Indiana 46556 (United States)

    2015-05-07

    We present the results of a Brillouin light scattering investigation of thermally excited spin wave eigenmodes in square arrays of either isolated rectangular dots of permalloy or twins of dipolarly coupled elements, placed side-by-side or head-to-tail. The nanodots, fabricated by e-beam lithography and lift-off, are 20 nm thick and have the major size D in the range between 90 nm and 150 nm. The experimental spectra show the presence of two main peaks, corresponding to modes localized either at the edges or in the center of the dots. Their frequency dependence on the dot size and on the interaction with adjacent elements has been measured and successfully interpreted on the basis of dynamical micromagnetic simulations. The latter enabled us also to describe the spatial profile of the eigenmodes, putting in evidence the effects induced by the dipolar interaction between coupled dots. In particular, in twinned dots the demagnetizing field is appreciably modified in proximity of the “internal edges” if compared to the “external” ones, leading to a splitting of the edge mode. These results can be relevant for the exploitation of sub-150 nm magnetic dots in new applications, such as magnonic metamaterials, bit-patterned storage media, and nano-magnetic logic devices.

  15. SC-FDE for MMF short reach optical interconnects using directly modulated 850 nm VCSELs

    DEFF Research Database (Denmark)

    Teichmann, Victor S. C.; Barreto, Andre N.; Pham, Tien Thang

    2012-01-01

    We propose the use of single-carrier frequency-domain equalization (SC-FDE) for the compensation of modal dispersion in short distance optical links using multimode fibers and 850 nm VCSELs. By post-processing of experimental data, we demonstrate, at 7.9% overhead, the error-free transmission (ov...

  16. Development of a new water sterilization device with a 365 nm UV-LED.

    Science.gov (United States)

    Mori, Mirei; Hamamoto, Akiko; Takahashi, Akira; Nakano, Masayuki; Wakikawa, Noriko; Tachibana, Satoko; Ikehara, Toshitaka; Nakaya, Yutaka; Akutagawa, Masatake; Kinouchi, Yohsuke

    2007-12-01

    Ultraviolet (UV) irradiation is an effective disinfection method. In sterilization equipment, a low-pressure mercury lamp emitting an effective germicidal UVC (254 nm) is used as the light source. However, the lamp, which contains mercury, must be disposed of at the end of its lifetime or following damage due to physical shock or vibration. We investigated the suitability of an ultraviolet light-emitting diode at an output wavelength of 365 nm (UVA-LED) as a sterilization device, comparing with the other wavelength irradiation such as 254 nm (a low-pressure mercury lam) and 405 nm (LED). We used a commercially available UVA-LED that emitted light at the shortest wavelength and at the highest output energy. The new sterilization system using the UVA-LED was able to inactivate bacteria, such as Escherichia coli DH5 alpha, Enteropathogenic E. coli, Vibrio parahaemolyticus, Staphylococcus aureus, and Salmonella enterica serovar Enteritidis. The inactivations of the bacteria were dependent on the accumulation of UVA irradiation. Taking advantage of the safety and compact size of LED devices, we expect that the UVA-LED sterilization device can be developed as a new type of water sterilization device.

  17. Fourier domain mode-locked swept source at 1050 nm based on a tapered amplifier

    DEFF Research Database (Denmark)

    Marschall, Sebastian; Klein, Thomas; Wieser, Wolfgang

    2010-01-01

    While swept source optical coherence tomography (OCT) in the 1050 nm range is promising for retinal imaging, there are certain challenges. Conventional semiconductor gain media have limited output power, and the performance of high-speed Fourier domain mode-locked (FDML) lasers suffers from...

  18. Broadband Fourier domain mode-locked laser for optical coherence tomography at 1060 nm

    DEFF Research Database (Denmark)

    Marschall, Sebastian; Klein, Thomas; Wieser, Wolfgang

    2012-01-01

    Optical coherence tomography (OCT) in the 1060nm range is interesting for in vivo imaging of the human posterior eye segment (retina, choroid, sclera) due to low absorption in water and deep penetration into the tissue. Rapidly tunable light sources, such as Fourier domain mode-locked (FDML) lasers...

  19. UVB 311 nm tolerance of vitiligo skin increases with skin photo type

    NARCIS (Netherlands)

    Caron-Schreinemachers, Anne-Lou D. B.; Kingswijk, Melanie M.; Bos, Jan D.; Westerhof, Wiete

    2005-01-01

    It is assumed that skin is protected against sunburn by melanin. In patients with vitiligo, there are white patches in the normal pigmented skin. We noticed that there is a difference in burning capacity of these white patches between people with different skin types. With UVB 311 nm lamps, we

  20. Nanostructured current-confined single quantum dot light-emitting diode at 1300 nm

    NARCIS (Netherlands)

    Monat, C.; Alloing, B.; Zinoni, C.; Li, L.; Fiore, A.

    2006-01-01

    A novel light-emitting-diode structure is demonstrated, which relies on nanoscale current injection through an oxide aperture to achieve selective excitation of single InAs/GaAs quantum dots. Low-temp. electroluminescence spectra evidence discrete narrow lines around 1300 nm (line width ~ 75 micro

  1. Diode lasers with asymmetric barriers for 850 nm spectral range: experimental studies of power characteristics

    DEFF Research Database (Denmark)

    Zubov, F. I.; Zhukov, A. E.; Shernyakov, Yu M.

    2015-01-01

    It is demonstrated that the use of asymmetric barrier layers in a waveguide of a diode laser suppress non-linearity of light-current characteristic and thus improve its power characteristics under high current injection. The results are presented for 850-nm AlGaAs/GaAs broad-area lasers with Ga...

  2. An approach for extracting the vein and heart boundaries from raw NM images

    International Nuclear Information System (INIS)

    Mitrovski, Cvetko D.; Kostov, Mitko B.

    2003-01-01

    In this paper we present our approach on prE.processing chest region dynamical NM images which enables anatomical data extraction of the vena cava and the heart. The aim of the method is developing sophisticated diagnostic software that could automatically offer the optimal positions and the shapes of the regions of interest needed for the heart studies. (Author)

  3. Synthesis of 2.5 nm colloidal iridium nanoparticles with strong surface enhanced Raman scattering activity

    International Nuclear Information System (INIS)

    Cui, Malin; Zhao, Yuan; Wang, Chan; Song, Qijun

    2016-01-01

    Colloidal iridium nanoparticles (IrNPs) were synthesized through an environmentally friendly approach by using trisodium citrate as the capping molecule in an aqueous medium. The resulting colloidal IrNPs have a typical diameter of 2.5 nm and display absorption bands at 250, 400 and 600 nm. They possess uniform morphology, good dispersibility, excellent stability in water, and exhibit strong surface enhanced Raman scattering (SERS) activity with an enhancement factor (EF) of 3.5 × 10 5 at the 1512 cm -1 peak when using Rhodamine 6G as the probe molecule. The excellent SERS performance of the IrNPs was exemplarily applied to the determination of the industrial colorant Sudan Red I. The peak intensity of the Raman band at 1236 cm -1 is linearly related to the concentration of Sudan Red I which can be determined by SERS in the 2 nM to 8 μM concentration range with a limit of detection as low as 0.6 nM. In our perception, this strong SERS activity of the IrNPs has a large potential in the SERS-based quantitation of various chemical substances. (author)

  4. The efficacy of selective calculus ablation at 400 nm: comparison to conventional calculus removal methods

    Science.gov (United States)

    Schoenly, Joshua E.; Seka, Wolf; Romanos, Georgios; Rechmann, Peter

    A desired outcome of scaling and root planing is the complete removal of calculus and infected root tissue and preservation of healthy cementum for rapid healing of periodontal tissues. Conventional periodontal treatments for calculus removal, such as hand instrument scaling and ultrasonic scaling, often deeply scrape the surface of the underlying hard tissue and may leave behind a smear layer. Pulsed lasers emitting at violet wavelengths (specifically, 380 to 400 nm) are a potential alternative treatment since they can selectively ablate dental calculus without ablating pristine hard tissue (i.e., enamel, cementum, and dentin). In this study, light and scanning electron microscopy are used to compare and contrast the efficacy of in vitro calculus removal for several conventional periodontal treatments (hand instruments, ultrasonic scaler, and Er:YAG laser) to calculus removal with a frequency-doubled Ti:sapphire (λ = 400 nm). After calculus removal, enamel and cementum surfaces are investigated for calculus debris and damage to the underlying hard tissue surface. Compared to the smear layer, grooves, and unintentional hard tissue removal typically found using these conventional treatments, calculus removal using the 400-nm laser is complete and selective without any removal of pristine dental hard tissue. Based on these results, selective ablation from the 400-nm laser appears to produce a root surface that would be more suitable for successful healing of periodontal tissues.

  5. Super continuum generation at 800 nm in highly nonlinear photonic crystal fibers with normal dispersion

    DEFF Research Database (Denmark)

    Hansen, Kim Per; Larsen, Jacob Juul; Jensen, Jacob Riis

    2001-01-01

    More than 90 nm broad self-phase modulation (SPM) induced pulses have been created from both 25 and 50 fs pulses in just 12.5 cm of fiber. The broadening is more than 2.5 times that observed in standard SMF. SPM broadening in PCFs has several advantages over more complex super continuum generatio...

  6. Mutagenesis of mNeptune Red-Shifts Emission Spectrum to 681-685 nm.

    Science.gov (United States)

    Li, ZhaoYang; Zhang, ZhiPing; Bi, LiJun; Cui, ZongQiang; Deng, JiaoYu; Wang, DianBing; Zhang, Xian-En

    2016-01-01

    GFP-like fluorescent proteins with diverse emission wavelengths have been developed through mutagenesis, offering many possible choices in cellular and tissue imaging, such as multi-targets imaging, deep tissue imaging that require longer emission wavelength. Here, we utilized a combined approach of random mutation and structure-based rational design to develop new NIR fluorescent proteins on the basis of a far-red fluorescent protein, mNeptune (Ex/Em: 600/650 nm). We created a number of new monomeric NIR fluorescent proteins with the emission range of 681-685 nm, which exhibit the largest Stocks shifts (77-80 nm) compared to other fluorescent proteins. Among them, mNeptune681 and mNeptune684 exhibit more than 30 nm redshift in emission relative to mNeptune, owing to the major role of the extensive hydrogen-bond network around the chromophore and contributions of individual mutations to the observed redshift. Furthermore, the two variants still maintain monomeric state in solution, which is a trait crucial for their use as protein tags. In conclusion, our results suggest that there is untapped potential for developing fluorescent proteins with desired properties.

  7. Efficient generation of 509 nm light by sum-frequency mixing between two tapered diode lasers

    DEFF Research Database (Denmark)

    Tawfieq, Mahmoud; Jensen, Ole Bjarlin; Hansen, Anders Kragh

    2015-01-01

    We demonstrate a concept for visible laser sources based on sum-frequency generation of beam com- bined tapered diode lasers. In this specific case, a 1.7 W sum-frequency generated green laser at 509 nm is obtained, by frequency adding of 6.17 W from a 978 nm tapered diode laser with 8.06 W from...... a 1063 nm tapered diode laser, inside a periodically poled MgO doped lithium niobate crystal. This corresponds to an optical to optical conversion ef fi ciency of 12.1%. As an example of potential applica- tions, the generated nearly diffraction-limited green light is used for pumping a Ti:sapphire laser......, thus demonstrating good beam quality and power stability. The maximum output powers achieved when pumping the Ti:sapphire laser are 226 mW (CW) and 185 mW (mode-locked) at 1.7 W green pump power. The optical spectrum emitted by the mode-locked Ti:sapphire laser shows a spectral width of about 54 nm...

  8. Efficient high power operation of erbium 3 µm fibre laser diode-pumped at 975 nm

    NARCIS (Netherlands)

    Jackson, S.D.; King, T.A.; Pollnau, Markus

    2000-01-01

    Efficient CW operation of a 2.71 um Er,Pr:ZBLAN double-clad fibre laser pumped with a single diode laser operating at a wavelength of 975 nm is described. A maximum output power of 0.5 W and a slope efficiency of 25% (with respect to the launched pump power) were obtained. Threshold pump powers of <

  9. 1-bit sub threshold full adders in 65nm CMOS technology

    DEFF Research Database (Denmark)

    Moradi, Farshad; Wisland, Dag T.; Tuan Vu, Cao

    In this paper a new full adder (FA) circuit optimized for ultra low power operation is proposed. The circuit is based on modified XOR gates operated in the subthreshold region to minimize the power consumption. Simulated results using 65 nm standarad CMOS models are provided. The simulation results...

  10. Acute and Cumulative Effects of Unmodified 50-nm Nano-ZnO on Mice.

    Science.gov (United States)

    Kong, Tao; Zhang, Shu-Hui; Zhang, Ji-Liang; Hao, Xue-Qin; Yang, Fan; Zhang, Cai; Yang, Zi-Jun; Zhang, Meng-Yu; Wang, Jie

    2018-01-02

    Nanometer zinc oxide (nano-ZnO) is widely used in diverse industrial and agricultural fields. Due to the extensive contact humans have with these particles, it is crucial to understand the potential effects that nano-ZnO have on human health. Currently, information related to the toxicity and mechanisms of nano-ZnO is limited. The aim of the present study was to investigate acute and cumulative toxic effects of 50-nm unmodified ZnO in mice. This investigation will seek to establish median lethal dose (LD50), a cumulative coefficient, and target organs. The acute and cumulative toxicity was investigated by Karber's method and via a dose-increasing method, respectively. During the experiment, clinical signs, mortality, body weights, hematology, serum biochemistry, gross pathology, organ weight, and histopathology were examined. The LD50 was 5177-mg/kg·bw; the 95% confidence limits for the LD50 were 5116-5238-mg/kg·bw. It could be concluded that the liver, kidney, lung, and gastrointestinal tract were target organs for the 50-nm nano-ZnO acute oral treatment. The cumulative coefficient (K) was 1.9 which indicated that the cumulative toxicity was apparent. The results also indicated that the liver, kidney, lung, and pancrea were target organs for 50-nm nano-ZnO cumulative oral exposure and might be target organs for subchronic and chronic toxicity of oral administered 50-nm ZnO.

  11. Oral two-generation reproduction toxicity study with NM-200 synthetic amorphous silica in Wistar rats

    NARCIS (Netherlands)

    Wolterbeek, A.; Oosterwijk, T.; Schneider, S.; Landsiedel, R.; Groot, D. de; Ee, R. van; Wouters, M.; Sandt, H. van de

    2015-01-01

    Synthetic amorphous silica (SAS) like NM-200 is used in a wide variety of technological applications and consumer products. Although SAS has been widely investigated the available reproductive toxicity studies are old and do not cover all requirements of current OECD Guidelines. As part of a

  12. 76 FR 76689 - Cibola National Forest, Mount Taylor Ranger District, NM, Mount Taylor Combined Exploratory Drilling

    Science.gov (United States)

    2011-12-08

    ... National Forest, Mount Taylor Ranger District, NM, Mount Taylor Combined Exploratory Drilling AGENCY... proposed action is to approve two Plans of Operations for exploratory uranium drilling on the Cibola... San Mateo. In total, there are up to 279 drill holes that would be drilled over a period not to exceed...

  13. Safety and efficacy of 2,790-nm laser resurfacing for chest photoaging.

    Science.gov (United States)

    Grunebaum, Lisa D; Murdock, Jennifer; Cofnas, Paul; Kaufman, Joely

    2015-01-01

    Chest photodamage is a common cosmetic complaint. Laser treatment of the chest may be higher risk than other areas. The objective of this study was to assess the safety and efficacy of 2,790-nm chest resurfacing for photodamage. Twelve patients with Fitzpatrick skin types I-III were enrolled in this university IRB-approved study. Photo documentation was obtained at baseline and each visit. A test spot with the 2,790-nm resurfacing laser was performed on the chest. Patients who did not have adverse effects from the test spot went on to have a full chest resurfacing procedure. Patients were instructed on standardized aftercare, including sunscreen. A 5-point healing and photodamage improvement scale was used to rate improvement by both investigators and the patients and was obtained at 2 weeks, 1 month, 2 months, and 3 months. One pass chest treatment with the 2,790-nm resurfacing laser at fluences greater than or equal to 3.0 mJ with 10% overlap leads to unacceptable rates of hyperpigmentation. Double pass chest treatment at fluences less than or equal to 2.5 mJ with 10% overlap leads to mild improvement in chest photodamage parameters without significant or persistent adverse effects. Laser treatment of aging/photodamaged chest skin remains a challenge due to the delicacy of chest skin. Mild improvement may be obtained with double pass resurfacing with the 2,790-nm wavelength.

  14. Efficient coupling of 527 nm laser beam power to a long scale-length plasma

    International Nuclear Information System (INIS)

    Moody, J.D.; Divol, L.; Glenzer, S.H.; MacKinnon, A.J.; Froula, D.H.; Gregori, G.; Kruer, W.L.; Meezan, N.B.; Suter, L.J.; Williams, E.A.; Bahr, R.; Seka, W.

    2006-01-01

    We experimentally demonstrate that application of laser smoothing schemes including smoothing by spectral dispersion (SSD) and polarization smoothing (PS) increases the intensity range for efficient coupling of frequency doubled (527 nm) laser light to a long scale-length plasma with n e /n cr equals 0.14 and T e equals 2 keV. (authors)

  15. In vitro double-integrating-sphere optical properties of tissues between 630 and 1064 nm

    Science.gov (United States)

    Beek, J. F.; Blokland, P.; Posthumus, P.; Aalders, M.; Pickering, J. W.; Sterenborg, H. J. C. M.; van Gemert, M. J. C.

    1997-11-01

    The optical properties (absorption and scattering coefficients and the scattering anisotropy factor) were measured in vitro for cartilage, liver, lung, muscle, myocardium, skin, and tumour (colon adenocarcinoma CC 531) at 630, 632.8, 790, 850 and 1064 nm. Rabbits, rats, piglets, goats, and dogs were used to obtain the tissues. A double-integrating-sphere setup with an intervening sample was used to determine the reflectance, and the diffuse and collimated transmittances of the sample. The inverse adding - doubling algorithm was used to determine the optical properties from the measurements. The overall results were comparable to those available in the literature, although only limited data are available at 790 - 850 nm. The results were reproducible for a specific sample at a specific wavelength. However, when comparing the results of different samples of the same tissue or different lasers with approximately the same wavelength (e.g. argon dye laser at 630 nm and HeNe laser at 632.8 nm) variations are large. We believe these variations in optical properties should be explained by biological variations of the tissues. In conclusion, we report on an extensive set of in vitro absorption and scattering properties of tissues measured with the same equipment and software, and by the same group. Although the accuracy of the method requires further improvement, it is highly likely that the other existing data in the literature have a similar level of accuracy.

  16. Formation of nickel germanides from Ni layers with thickness below 10 nm

    Energy Technology Data Exchange (ETDEWEB)

    Jablonka, Lukas; Kubart, Tomas; Primetzhofer, Daniel; Abedin, Ahmad; Hellström, Per-Erik; Östling, Mikael; Jordan-Sweet, Jean; Lavoie, Christian; Zhang, Shi-Li; Zhang, Zhen

    2017-03-01

    The authors have studied the reaction between a Ge (100) substrate and thin layers of Ni ranging from 2 to 10 nm in thickness. The formation of metal-rich Ni5Ge3Ni5Ge3 was found to precede that of the monogermanide NiGe by means of real-time in situ x-ray diffraction during ramp-annealing and ex situ x-ray pole figure analyses for phase identification. The observed sequential growth of Ni5Ge3Ni5Ge3 and NiGe with such thin Ni layers is different from the previously reported simultaneous growth with thicker Ni layers. The phase transformation from Ni5Ge3Ni5Ge3 to NiGe was found to be nucleation-controlled for Ni thicknesses <5 nm<5 nm, which is well supported by thermodynamic considerations. Specifically, the temperature for the NiGe formation increased with decreasing Ni (rather Ni5Ge3Ni5Ge3) thickness below 5 nm. In combination with sheet resistance measurement and microscopic surface inspection of samples annealed with a standard rapid thermal processing, the temperature range for achieving morphologically stable NiGe layers was identified for this standard annealing process. As expected, it was found to be strongly dependent on the initial Ni thickness

  17. Evaluation of skin melanoma in spectral range 450-950 nm using principal component analysis

    Science.gov (United States)

    Jakovels, D.; Lihacova, I.; Kuzmina, I.; Spigulis, J.

    2013-06-01

    Diagnostic potential of principal component analysis (PCA) of multi-spectral imaging data in the wavelength range 450- 950 nm for distant skin melanoma recognition is discussed. Processing of the measured clinical data by means of PCA resulted in clear separation between malignant melanomas and pigmented nevi.

  18. Sub-50 nm patterning of functional oxides by soft lithographic edge printing

    NARCIS (Netherlands)

    George, A.; ten Elshof, Johan E.

    2012-01-01

    We report a fast, versatile and reproducible method to make arbitrary nanoscale patterns of functional metal oxides by edge transfer printing of aqueous metal-loaded water-soluble polyacrylic acid (PAA) solutions on silicon. Patterns of ZnO, CuO, NiO and Fe2O3 with lateral dimensions below 50 nm

  19. Bactericidal effect of a 405-nm diode laser on Porphyromonas gingivalis

    International Nuclear Information System (INIS)

    Kotoku, Y; Kato, J; Akashi, G; Hirai, Y; Ishihara, K

    2009-01-01

    The study was conducted to determine the effect of 405-nm diode laser irradiation on periodontopathic bacteria such as Porphyromonas gingivalis in vitro. A diluted suspension of P. gingivalis was irradiated directly with a 405-nm diode laser under conditions of 100 mW-10 sec, 100 mW-20 sec, 200 mW-5 sec, 200 mW-10 sec, 200 mW-20 sec, 400 mW-5 sec, 400 mW-10 sec, and 400 mW-20 sec. The energy density ranged from 2.0 to 16.0 J/cm 2 . The irradiated bacterial suspension was spread on a blood agar plate and growth of the colonies was examined after an anaerobic culture for 7 days. Bacterial growth was inhibited under all irradiation conditions, but the bactericidal effect of the 405-nm diode laser depended on the energy density. More than 97% of bacterial growth was inhibited with irradiation at an energy density > 4.0 J/cm 2 . The mechanism of the bactericidal effect is photochemical, rather than photothermal. These findings suggest that a 405-nm diode laser has a high bactericidal effect on P. gingivalis

  20. Bactericidal effect of a 405-nm diode laser on Porphyromonas gingivalis

    Science.gov (United States)

    Kotoku, Y.; Kato, J.; Akashi, G.; Hirai, Y.; Ishihara, K.

    2009-05-01

    The study was conducted to determine the effect of 405-nm diode laser irradiation on periodontopathic bacteria such as Porphyromonas gingivalis in vitro. A diluted suspension of P. gingivalis was irradiated directly with a 405-nm diode laser under conditions of 100 mW-10 sec, 100 mW-20 sec, 200 mW-5 sec, 200 mW-10 sec, 200 mW-20 sec, 400 mW-5 sec, 400 mW-10 sec, and 400 mW-20 sec. The energy density ranged from 2.0 to 16.0 J/cm2. The irradiated bacterial suspension was spread on a blood agar plate and growth of the colonies was examined after an anaerobic culture for 7 days. Bacterial growth was inhibited under all irradiation conditions, but the bactericidal effect of the 405-nm diode laser depended on the energy density. More than 97% of bacterial growth was inhibited with irradiation at an energy density > 4.0 J/cm2. The mechanism of the bactericidal effect is photochemical, rather than photothermal. These findings suggest that a 405-nm diode laser has a high bactericidal effect on P. gingivalis.