WorldWideScience

Sample records for setting exposure standards

  1. Repair mechanisms and exposure standards

    International Nuclear Information System (INIS)

    Mills, W.A.

    1978-01-01

    The following topics are discussed; public policy for setting radiation standards; use of linear, nonthreshold theory in setting radiation standards; dose-rate dependence; occupational exposure to radiation; radon inhalation from radium in the soil in the vicinity of the phosphate industry; relation of repair mechanisms for cell survival to cancer induction; application of information on genetic repair to humans and to cancer induction; importance of repair processes in radiation protection standards; corrective factors for repair processes; relation of repair processes to age, sex, and other factors; and population distribution in radiosensitivity

  2. Natural background approach to setting radiation standards

    International Nuclear Information System (INIS)

    Adler, H.I.; Federow, H.; Weinberg, A.M.

    1979-01-01

    The suggestion has often been made that an additional radiation exposure imposed on humanity as a result of some important activity such as electricity generation would be acceptable if the exposure was small compared to the natural background. In order to make this concept quantitative and objective, we propose that small compared with the natural background be interpreted as the standard deviation (weighted with the exposed population) of the natural background. This use of the variation in natural background radiation is less arbitrary and requires fewer unfounded assumptions than some current approaches to standard-setting. The standard deviation is an easily calculated statistic that is small compared with the mean value for natural exposures of populations. It is an objectively determined quantity and its significance is generally understood. Its determination does not omit any of the pertinent data. When this method is applied to the population of the United States, it suggests that a dose of 20 mrem/year would be an acceptable standard. This is comparable to the 25 mrem/year suggested as the maximum allowable exposure to an individual from the complete uranium fuel cycle

  3. Comparison of the rationale used in setting occupational exposure standards for ionizing radiation and hazardous chemical substances

    International Nuclear Information System (INIS)

    Halton, D.M.

    1986-12-01

    Ten chemicals which create significant occupational hazard are reviewed. They are toluene diisocyanate, hydrogen fluoride, n-hexane, carbon disulphide, cadmium, inorganic mercury, cobalt, nitroglycerol, silica and vinyl chloride. Each is discussed under the headings of physiological intake and elimination in humans, characteristics of acute and chronic toxicity, sites of occupational exposure and rationale for limits of such exposure. Since radioactive substances yield ionizing radiation as the common hazard the treatment of the current permissible levels of exposure is somewhat simpler. Having set out industrial standards for exposure to hazardous substances and radionuclides, a detailed comparison is made. Exposure limits to ioninzing radiation are sufficiently low to remove the appearance of directly related injury. It is expected however that low level exposure may have a stochastic effect, that is, there is the possibility of a slightly increased incidence of neoplasms in a large exposed population, but numbers will be too small to be able to attribute any particular case to the exposure. TLVs on the other hand, depending on the particular chemical, may be high enough in the workplace to permit some directly related signs or symptoms in the exposed individual. 244 refs

  4. Aerosol exposure: Concepts, criteria, standards and applications

    International Nuclear Information System (INIS)

    Vincent, James H

    2009-01-01

    This paper places Inhaled Particles X in the context of the whole sequence of such symposia, going back to the first one in 1961. It draws together some of the essential principles that have been learned since that earlier meeting about the nature of exposure and exposure assessment and thus provides a framework by which to integrate the new knowledge presented at this latest one. In the process, the importance of understanding the formal definition of aerosol exposure is stressed, including the distinction between exposure intensity and exposure history, and how that relates to some measure of cumulative dose which, in turn, may be linked with knowledge about intrinsic toxicity, etc. This then leads to a definition of exposure standards, and the important ingredients of criteria, sampling and limit values. A summary is provided of the current set of particle size-selective criteria that have been widely agreed in the international occupational and environmental health community. Some ideas are presented about how this set might be expanded for certain applications, the important case of ultrafine aerosols being one of them.

  5. The natural background approach to setting radiation standards

    International Nuclear Information System (INIS)

    Adler, H.I.; Federow, H.; Weinberg, A.M.

    1979-01-01

    The suggestion has often been made that an additional radiation exposure imposed on humanity as a result of some important activity such as electricity generation would be acceptable if the exposure was 'small' compared to the natural background. In order to make this concept quantitative and objective, we propose that 'small compared with the natural background' be interpreted as the standard deviation (weighted with the exposed population) of the natural background. We believe that this use of the variation in natural background radiation is less arbitrary and requires fewer unfounded assumptions than some current approaches to standard-setting. The standard deviation is an easily calculated statistic that is small compared with the mean value for natural exposures of populations. It is an objectively determined quantity and its significance is generally understood. Its determination does not omit any of the pertinent data. When this method is applied to the population of the USA, it implies that a dose of 20 mrem/year would be an acceptable standard. This is closely comparable to the 25 mrem/year suggested by the Environmental Protection Agency as the maximum allowable exposure to an individual in the general population as a result of the operation of the complete uranium fuel cycle. Other agents for which a natural background exists can be treated in the same way as radiation. In addition, a second method for determining permissible exposure levels for agents other than radiation is presented. This method makes use of the natural background radiation data as a primary standard. Some observations on benzo(a)pyrene, using this latter method, are presented. (author)

  6. Internal emitter research and standard setting

    International Nuclear Information System (INIS)

    Stannard, J.N.

    1981-01-01

    The history of the use of data from internal emitter research in the derivation of safety standards is reviewed. At first, observed biological effects were correlated with body burdens or exposure levels. This direct approach is illustrated by detailed accounts of the cases of uranium and plutonium. In the 1950's, when it was decided to provide standards for over 200 isotopes, the direct approach was replaced by a system of calculations. This necessitated changes in internal emitter research programs to provide metabolic data, and the development of models such as Reference Man and the Lung and Gastrointestinal Tract models. The continuing contribution of internal emitter research to standard setting can be seen in the references quoted in the metabolic data section of the new ICRP report (ICRP Publication 30). Present trends suggest a possible return to the direct use of internal emitter effects data for obtaining risk estimates. (U.K.)

  7. OSHA's approach to risk assessment for setting a revised occupational exposure standard for 1,3-butadiene.

    Science.gov (United States)

    Grossman, E A; Martonik, J

    1990-01-01

    In its 1980 benzene decision [Industrial Union Department, ALF-CIO v. American Petroleum Institute, 448 U.S. 607 (1980)], the Supreme Court ruled that "before he can promulgate any permanent health or safety standard, the Secretary [of Labor] is required to make a threshold finding that a place of employment is unsafe--in the sense that significant risks are present and can be lessened by a change in practices" (448 U.S. at 642). The Occupational Safety and Health Administration (OSHA) has interpreted this to mean that whenever possible, it must quantify the risk associated with occupational exposure to a toxic substance at the current permissible exposure limit (PEL). If OSHA determines that there is significant risk to workers' health at its current standard, then it must quantify the risk associated with a variety of alternative standards to determine at what level, if any, occupational exposure to a substance no longer poses a significant risk. For rulemaking on occupational exposure to 1,3-butadiene, there are two studies that are suitable for quantitative risk assessment. One is a mouse inhalation bioassay conducted by the National Toxicology Program (NTP), and the other is a rat inhalation bioassay conducted by Hazelton Laboratories Europe. Of the four risk assessments that have been submitted to OSHA, all four have used the mouse and/or rat data with a variety of models to quantify the risk associated with occupational exposure to 1,3-butadiene. In addition, OSHA has performed its own risk assessment using the female mouse and female rat data and the one-hit and multistage models.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:2401254

  8. Comparative evaluation of different methods of setting hygienic standards

    International Nuclear Information System (INIS)

    Ramzaev, P.V.; Rodionova, L.F.; Mashneva, N.I.

    1978-01-01

    Long-term experiments were carried out on white mice and rats to study the relative importance of various procedures used in setting hygienic standards for exposure to adverse factors. A variety of radionuclides and chemical substances were tested and the sensitivities to them of various indices of the bodily state were determined. For each index, statistically significant minimal effective concentrations of substances were established

  9. Determinants of corporate lobbying intensity in the lease standard-setting process

    Directory of Open Access Journals (Sweden)

    Lucia Mellado

    2017-07-01

    Full Text Available The highly controversial lease standard-setting project that will replace the standards currently in place, establishes a new approach that includes the recognition of all assets and liabilities associated with lease contracts on the balance sheet, regardless of their classification. The complex standard-setting process and the heated debate among stakeholders makes the analysis of the lobbying phenomenon an important matter for study. The aim of this paper is to find explanatory factors that predict the behaviour of corporate groups with respect to the lease standard-setting process. To achieve this objective, we scrutinize the submission of comment letters by 306 non-financial listed companies in response to the discussion paper (DP 2009 and two exposure drafts (ED 2010 and ED 2013 elaborated jointly by the IASB and the FASB by distinguishing among three degrees of intensity in lobbying activities, depending on participation in the different discussion periods. Our empirical study is conducted through a multivariate analysis that shows the intensity of lobbying by considering participation in the three consultation periods. The results show that the intensity of lobbying is associated with size, profitability, age, industry and managerial ownership. The evidence can be used to predict lobbying behaviour. The research has implications for standard setters and contributes to prior lobbying research.

  10. Rough Standard Neutrosophic Sets: An Application on Standard Neutrosophic Information Systems

    Directory of Open Access Journals (Sweden)

    Nguyen Xuan Thao

    2016-12-01

    Full Text Available A rough fuzzy set is the result of the approximation of a fuzzy set with respect to a crisp approximation space. It is a mathematical tool for the knowledge discovery in the fuzzy information systems. In this paper, we introduce the concepts of rough standard neutrosophic sets and standard neutrosophic information system, and give some results of the knowledge discovery on standard neutrosophic information system based on rough standard neutrosophic sets.

  11. Setting the standard: The IAEA safety standards set the global reference

    International Nuclear Information System (INIS)

    Williams, L.

    2003-01-01

    For the IAEA, setting and promoting standards for nuclear radiation, waste, and transport safety have been priorities from the start, rooted in the Agency's 1957 Statute. Today, a corpus of international standards are in place that national regulators and industries in many countries are applying, and more are being encouraged and assisted to follow them. Considerable work is done to keep safety standards updated and authoritative. They cover five main areas: the safety of nuclear facilities; radiation protection and safety of radiation sources; safe management of radioactive waste; safe transport of radioactive material; and thematic safety areas, such as emergency preparedness or legal infrastructures. Overall, the safety standards reflect an international consensus on what constitutes a high level of safety for protecting people and the environment. All IAEA Member States can nominate experts for the Agency standards committees and provide comments on draft standards. Through this ongoing cycle of review and feedback, the standards are refined, updated, and extended where needed

  12. Repeated Interaction in Standard Setting

    NARCIS (Netherlands)

    Larouche, Pierre; Schütt, Florian

    2016-01-01

    As part of the standard-setting process, certain patents become essential. This may allow the owners of these standard-essential patents to hold up implementers of the standard, who can no longer turn to substitute technologies. However, many real-world standards evolve over time, with several

  13. Standard-Setting Methods as Measurement Processes

    Science.gov (United States)

    Nichols, Paul; Twing, Jon; Mueller, Canda D.; O'Malley, Kimberly

    2010-01-01

    Some writers in the measurement literature have been skeptical of the meaningfulness of achievement standards and described the standard-setting process as blatantly arbitrary. We argue that standard setting is more appropriately conceived of as a measurement process similar to student assessment. The construct being measured is the panelists'…

  14. Accounting for human variability and sensitivity in setting standards for electromagnetic fields.

    Science.gov (United States)

    Bailey, William H; Erdreich, Linda S

    2007-06-01

    Biological sensitivity and variability are key issues for risk assessment and standard setting. Variability encompasses general inter-individual variations in population responses, while sensitivity relates to unusual or extreme responses based on genetic, congenital, medical, or environmental conditions. For risk assessment and standard setting, these factors affect estimates of thresholds for effects and dose-response relationships and inform efforts to protect the more sensitive members of the population, not just the typical or average person. While issues of variability and sensitivity can be addressed by experimental and clinical studies of electromagnetic fields, investigators have paid little attention to these important issues. This paper provides examples that illustrate how default assumptions regarding variability can be incorporated into estimates of 60-Hz magnetic field exposures with no risk of cardiac stimulation and how population thresholds and variability of peripheral nerve stimulation responses at 60-Hz can be estimated from studies of pulsed gradient magnetic fields in magnetic resonance imaging studies. In the setting of standards for radiofrequency exposures, the International Commission for Non-Ionizing Radiation Protection uses inter-individual differences in thermal sensitivity as one of the considerations in the development of "safety factors." However, neither the range of sensitivity nor the sufficiency or excess of the 10-fold and the additional 5-fold safety factors have been assessed quantitatively. Data on the range of responses between median and sensitive individuals regarding heat stress and cognitive function should be evaluated to inform a reassessment of these safety factors and to identify data gaps.

  15. Constructing an exposure chart: step by step (based on standard procedures)

    International Nuclear Information System (INIS)

    David, Jocelyn L; Cansino, Percedita T.; Taguibao, Angileo P.

    2000-01-01

    An exposure chart is very important in conducting radiographic inspection of materials. By using an accurate exposure chart, an inspector is able to avoid a trial and error way of determining correct time to expose a specimen, thereby producing a radiograph that has an acceptable density based on a standard. The chart gives the following information: x-ray machine model and brand, distance of the x-ray tube from the film, type and thickness of intensifying screens, film type, radiograph density, and film processing conditions. The methods of preparing an exposure chart are available in existing radiographic testing manuals. These described methods are presented in step by step procedures, covering the actual laboratory set-up, data gathering, computations, and transformation of derived data into Characteristic Curve and Exposure Chart

  16. National Standard for Limiting Occupational Exposure to Ionizing Radiation. NOHSC:1013(1995)

    International Nuclear Information System (INIS)

    1995-06-01

    The objectives of The National Standard for Limiting Occupational Exposure to Ionizing Radiation are to limit the risk to health arising from exposure to ionizing radiation in the workplace and to optimize radiation protection by setting common essential requirements for the control of exposure to radiation, including the specification of employer duties and employee duties. It serves to identify the provisions which are to be made in the regulations of States, Territories and the Commonwealth for the control of occupational exposure to radiation. It is recognised that legislation, including regulations, may already exist which covers all or part of the scope of this Standard. It is also recognised that it may not be appropriate to take up this Standard verbatim because of differing legislative frameworks and drafting conventions in each State and Territory and in the Commonwealth. However, it is expected that the implementation of the provisions contained in this Standard will be nationally consistent. This Standard deals only with occupational health and safety matters related to exposure to ionizing radiation; the appropriate authority should be consulted about other radiation control requirements which may apply. The complementary 'Recommendations for Limiting Exposure to Ionizing Radiation' - Guidance note NOHSC:3022(1995)- Radiation Health series no. 39 - describes the principles and practice on which this Standard is based and provides interpretive and reference material. It supersedes earlier recommendations of the NHMRC: Recommended Radiation Protection Standards for Individuals Exposed to Ionising Radiation, adopted in 1980, Australia's Radiation Protection Standards (1989) and the Interim on Australia's Radiation Protection Standards (1991). These revised Recommendations for application in Australia take into account the most recent recommendations of the ICRP, which were adopted after careful review of all available scientific evidence concerning the

  17. Standard setting: comparison of two methods.

    Science.gov (United States)

    George, Sanju; Haque, M Sayeed; Oyebode, Femi

    2006-09-14

    The outcome of assessments is determined by the standard-setting method used. There is a wide range of standard-setting methods and the two used most extensively in undergraduate medical education in the UK are the norm-reference and the criterion-reference methods. The aims of the study were to compare these two standard-setting methods for a multiple-choice question examination and to estimate the test-retest and inter-rater reliability of the modified Angoff method. The norm-reference method of standard-setting (mean minus 1 SD) was applied to the 'raw' scores of 78 4th-year medical students on a multiple-choice examination (MCQ). Two panels of raters also set the standard using the modified Angoff method for the same multiple-choice question paper on two occasions (6 months apart). We compared the pass/fail rates derived from the norm reference and the Angoff methods and also assessed the test-retest and inter-rater reliability of the modified Angoff method. The pass rate with the norm-reference method was 85% (66/78) and that by the Angoff method was 100% (78 out of 78). The percentage agreement between Angoff method and norm-reference was 78% (95% CI 69% - 87%). The modified Angoff method had an inter-rater reliability of 0.81-0.82 and a test-retest reliability of 0.59-0.74. There were significant differences in the outcomes of these two standard-setting methods, as shown by the difference in the proportion of candidates that passed and failed the assessment. The modified Angoff method was found to have good inter-rater reliability and moderate test-retest reliability.

  18. Standardized approach for developing probabilistic exposure factor distributions

    Energy Technology Data Exchange (ETDEWEB)

    Maddalena, Randy L.; McKone, Thomas E.; Sohn, Michael D.

    2003-03-01

    The effectiveness of a probabilistic risk assessment (PRA) depends critically on the quality of input information that is available to the risk assessor and specifically on the probabilistic exposure factor distributions that are developed and used in the exposure and risk models. Deriving probabilistic distributions for model inputs can be time consuming and subjective. The absence of a standard approach for developing these distributions can result in PRAs that are inconsistent and difficult to review by regulatory agencies. We present an approach that reduces subjectivity in the distribution development process without limiting the flexibility needed to prepare relevant PRAs. The approach requires two steps. First, we analyze data pooled at a population scale to (1) identify the most robust demographic variables within the population for a given exposure factor, (2) partition the population data into subsets based on these variables, and (3) construct archetypal distributions for each subpopulation. Second, we sample from these archetypal distributions according to site- or scenario-specific conditions to simulate exposure factor values and use these values to construct the scenario-specific input distribution. It is envisaged that the archetypal distributions from step 1 will be generally applicable so risk assessors will not have to repeatedly collect and analyze raw data for each new assessment. We demonstrate the approach for two commonly used exposure factors--body weight (BW) and exposure duration (ED)--using data for the U.S. population. For these factors we provide a first set of subpopulation based archetypal distributions along with methodology for using these distributions to construct relevant scenario-specific probabilistic exposure factor distributions.

  19. Standard setting: Comparison of two methods

    Directory of Open Access Journals (Sweden)

    Oyebode Femi

    2006-09-01

    Full Text Available Abstract Background The outcome of assessments is determined by the standard-setting method used. There is a wide range of standardsetting methods and the two used most extensively in undergraduate medical education in the UK are the norm-reference and the criterion-reference methods. The aims of the study were to compare these two standard-setting methods for a multiple-choice question examination and to estimate the test-retest and inter-rater reliability of the modified Angoff method. Methods The norm – reference method of standard -setting (mean minus 1 SD was applied to the 'raw' scores of 78 4th-year medical students on a multiple-choice examination (MCQ. Two panels of raters also set the standard using the modified Angoff method for the same multiple-choice question paper on two occasions (6 months apart. We compared the pass/fail rates derived from the norm reference and the Angoff methods and also assessed the test-retest and inter-rater reliability of the modified Angoff method. Results The pass rate with the norm-reference method was 85% (66/78 and that by the Angoff method was 100% (78 out of 78. The percentage agreement between Angoff method and norm-reference was 78% (95% CI 69% – 87%. The modified Angoff method had an inter-rater reliability of 0.81 – 0.82 and a test-retest reliability of 0.59–0.74. Conclusion There were significant differences in the outcomes of these two standard-setting methods, as shown by the difference in the proportion of candidates that passed and failed the assessment. The modified Angoff method was found to have good inter-rater reliability and moderate test-retest reliability.

  20. X-ray exposure from colour TV sets

    International Nuclear Information System (INIS)

    Nambi, K.S.V.; Viswanathan, P.S.

    1988-01-01

    A survey has been made of the X-ray exposures from colour television sets of eight different brands manufactured in India and one of foreign make. The high sensitivity of natural CaF 2 TL phosphor to low energy photons has been taken advantage of, in measuring the extremely low levels of the X-ray emis sion from the TV sets. The measured exposures range from 8 to 27 μRh -1 and are well below the radiation safety limit internationally adopted. (author). 4 tabs

  1. A Generalizability Theory Approach to Standard Error Estimates for Bookmark Standard Settings

    Science.gov (United States)

    Lee, Guemin; Lewis, Daniel M.

    2008-01-01

    The bookmark standard-setting procedure is an item response theory-based method that is widely implemented in state testing programs. This study estimates standard errors for cut scores resulting from bookmark standard settings under a generalizability theory model and investigates the effects of different universes of generalization and error…

  2. A novel method for standardized application of fungal spore coatings for mosquito exposure bioassays.

    Science.gov (United States)

    Farenhorst, Marit; Knols, Bart G J

    2010-01-20

    Interest in the use of fungal entomopathogens against malaria vectors is growing. Fungal spores infect insects via the cuticle and can be applied directly on the insect to evaluate infectivity. For flying insects such as mosquitoes, however, application of fungal suspensions on resting surfaces is more realistic and representative of field settings. For this type of exposure, it is essential to apply specific amounts of fungal spores homogeneously over a surface for testing the effects of fungal dose and exposure time. Contemporary methods such as spraying or brushing spore suspensions onto substrates do not produce the uniformity and consistency that standardized laboratory assays require. Two novel fungus application methods using equipment developed in the paint industry are presented and compared. Wired, stainless steel K-bars were tested and optimized for coating fungal spore suspensions onto paper substrates. Different solvents and substrates were evaluated. Two types of coating techniques were compared, i.e. manual and automated coating. A standardized bioassay set-up was designed for testing coated spores against malaria mosquitoes. K-bar coating provided consistent applications of spore layers onto paper substrates. Viscous Ondina oil formulations were not suitable and significantly reduced spore infectivity. Evaporative Shellsol T solvent dried quickly and resulted in high spore infectivity to mosquitoes. Smooth proofing papers were the most effective substrate and showed higher infectivity than cardboard substrates. Manually and mechanically applied spore coatings showed similar and reproducible effects on mosquito survival. The standardized mosquito exposure bioassay was effective and consistent in measuring effects of fungal dose and exposure time. K-bar coating is a simple and consistent method for applying fungal spore suspensions onto paper substrates and can produce coating layers with accurate effective spore concentrations. The mosquito bioassay

  3. A novel method for standardized application of fungal spore coatings for mosquito exposure bioassays

    Directory of Open Access Journals (Sweden)

    Knols Bart GJ

    2010-01-01

    Full Text Available Abstract Background Interest in the use of fungal entomopathogens against malaria vectors is growing. Fungal spores infect insects via the cuticle and can be applied directly on the insect to evaluate infectivity. For flying insects such as mosquitoes, however, application of fungal suspensions on resting surfaces is more realistic and representative of field settings. For this type of exposure, it is essential to apply specific amounts of fungal spores homogeneously over a surface for testing the effects of fungal dose and exposure time. Contemporary methods such as spraying or brushing spore suspensions onto substrates do not produce the uniformity and consistency that standardized laboratory assays require. Two novel fungus application methods using equipment developed in the paint industry are presented and compared. Methods Wired, stainless steel K-bars were tested and optimized for coating fungal spore suspensions onto paper substrates. Different solvents and substrates were evaluated. Two types of coating techniques were compared, i.e. manual and automated coating. A standardized bioassay set-up was designed for testing coated spores against malaria mosquitoes. Results K-bar coating provided consistent applications of spore layers onto paper substrates. Viscous Ondina oil formulations were not suitable and significantly reduced spore infectivity. Evaporative Shellsol T solvent dried quickly and resulted in high spore infectivity to mosquitoes. Smooth proofing papers were the most effective substrate and showed higher infectivity than cardboard substrates. Manually and mechanically applied spore coatings showed similar and reproducible effects on mosquito survival. The standardized mosquito exposure bioassay was effective and consistent in measuring effects of fungal dose and exposure time. Conclusions K-bar coating is a simple and consistent method for applying fungal spore suspensions onto paper substrates and can produce coating layers

  4. Experiences from occupational exposure limits set on aerosols containing allergenic proteins

    DEFF Research Database (Denmark)

    Nielsen, Gunnar; Larsen, Søren; Hansen, Jitka S

    2012-01-01

    Occupational exposure limits (OELs) together with determined airborne exposures are used in risk assessment based managements of occupational exposures to prevent occupational diseases. In most countries, OELs have only been set for few protein-containing aerosols causing IgE-mediated allergies. ...... is available for setting OELs for proteins and protein-containing aerosols where the critical effect is IgE sensitization and IgE-mediated airway diseases.......Occupational exposure limits (OELs) together with determined airborne exposures are used in risk assessment based managements of occupational exposures to prevent occupational diseases. In most countries, OELs have only been set for few protein-containing aerosols causing IgE-mediated allergies...... for setting OELs. Our aim is to analyse prerequisites for setting OELs for the allergenic protein-containing aerosols. Opposite to the key effect of toxicological reactions, two thresholds, one for the sensitization phase and one for elicitation of IgE-mediated symptoms in sensitized individuals, are used...

  5. The effect of the OSHA lead exposure in construction standard on blood lead levels among iron workers employed in bridge rehabilitation.

    Science.gov (United States)

    Levin, S M; Goldberg, M; Doucette, J T

    1997-03-01

    Over 50,000 workers are at risk of occupational exposure to lead in the course of renovating the nation's deteriorating infrastructure. In mid-1993, to control exposure to lead in the construction setting OSHA promulgated a Lead in Construction Standard. In this study, we assessed the effect of the mandated changes in exposure conditions which followed the introduction of this new standard. We analyzed changes in baseline and maximum blood lead concentrations and in maximum increments in blood lead levels before and after introduction of the standard among iron workers employed in the renovation of a large, lead-painted, steel bridge in New York City. Results indicated that baseline and maximum blood lead levels fell significantly after the implementation of the provisions of the standard, as did maximum increments in blood lead concentrations. Seventy-six percent of the workers maintained blood lead concentrations below 20 micrograms/dl after the OSHA standard, as compared with 66% prior to its implementation. Increments of 20 micrograms/dl or more occurred considerably more frequently before introduction of the standard (13% before vs. 4% after; p = 0.01). Evidence of decreased exposure to lead was observed among iron workers who were present both before and after the introduction of the OSHA standard, as well as among iron workers newly hired after the OSHA provisions were put in place. These findings document the effectiveness of the OSHA construction lead standard in controlling exposure to lead in this complex and variable environment. The data indicate the utility of blood lead determinations in assessing the outcome of industrial hygiene interventions to reduce exposures to lead in the construction setting.

  6. The standard set game of a cooperative game

    NARCIS (Netherlands)

    Bumb, A.F.; Hoede, C.

    2003-01-01

    We show that for every cooperative game a corresponding set game can be defined, called the standard set game. Values for set games can be applied to this standard game and determine allocations for the cooperative game. On the other hand, notions for cooperative games, like the Shapley value, the

  7. Reliability and Validity of 10 Different Standard Setting Procedures.

    Science.gov (United States)

    Halpin, Glennelle; Halpin, Gerald

    Research indicating that different cut-off points result from the use of different standard-setting techniques leaves decision makers with a disturbing dilemma: Which standard-setting method is best? This investigation of the reliability and validity of 10 different standard-setting approaches was designed to provide information that might help…

  8. Construct Maps as a Foundation for Standard Setting

    Science.gov (United States)

    Wyse, Adam E.

    2013-01-01

    Construct maps are tools that display how the underlying achievement construct upon which one is trying to set cut-scores is related to other information used in the process of standard setting. This article reviews what construct maps are, uses construct maps to provide a conceptual framework to view commonly used standard-setting procedures (the…

  9. Noise exposure in occupational setting associated with elevated blood pressure in China

    Directory of Open Access Journals (Sweden)

    Shuchang Chen

    2017-01-01

    Full Text Available Abstract Background Hypertension is the primary out-auditory adverse outcome caused due to occupational noise exposure. This study investigated the associations of noise exposure in an occupational setting with blood pressure and risk of hypertension. Methods A total of 1,390 occupational noise-exposed workers and 1399 frequency matched non-noise-exposed subjects were recruited from a cross-sectional survey of occupational noise-exposed and the general population, respectively. Blood pressure was measured using a mercury sphygmomanometer following a standard protocol. Multiple logistic regression was used to calculate the odds ratio (OR and 95% confidence interval (CI of noise exposure adjusted by potential confounders. Results Noise-exposed subjects had significantly higher levels of systolic blood pressure(SBP (125.1 ± 13.9 mm Hg and diastolic blood pressure (DBP (77.6 ± 10.7 mm Hg than control subjects (SBP: 117.2 ± 15.7 mm Hg, DBP: 70.0 ± 10.5 mm Hg (P  0.05. Conclusions Occupational noise exposure was associated with higher levels of SBP, DBP, and the risk of hypertension. These findings indicate that effective and feasible measures should be implemented to reduce the risk of hypertension caused by occupational noise exposure.

  10. Exposure Control--OSHA's Bloodborne Pathogens Standard.

    Science.gov (United States)

    Granville, Mark F.

    1993-01-01

    Explains schools' responsibilities in complying with the Occupational Safety and Health Administration's (OSHA) Bloodborne Pathogens Standard. Describes exposure determination plan, protective equipment, housekeeping practices, labeling of waste, training employees, hepatitis B vaccinations, postexposure evaluation and medical follow-up, and…

  11. Development of human exposure standards for radio frequency fields

    International Nuclear Information System (INIS)

    Lin, James C.

    2000-01-01

    Historical aspects of the problem of developing human exposure standards for radio frequency (RF) electromagnetic fields are discussed. It is shown that biological effects and health implications of radiofrequency (RF) electromagnetic fields have been a subject of scientific investigation for more than 50 years. It has become a focus of attention because of the expanded use of RF radiation in the frequency range between 300 MHz and 6 GHz for wireless communication over the past decade. Another cause for the attention is the uncertainty of some observed responses and lack of understanding of the mechanism of interaction of RF electromagnetic fields with biological systems. At present, considerable efforts are devoted to developing and revising RF exposure standards. Each of these efforts should aim to make explicit the philosophy and process by which they reason and decide guidelines for deeming exposure as safe. Furthermore, the reconciliation of philosophies of protection will definitely be an asset, in practice, to those interested in international harmonization of RF exposure standards [ru

  12. Legal consequences of standard setting for competitive athletes with cardiovascular abnormalities.

    Science.gov (United States)

    Weistart, J C

    1985-12-01

    This paper addresses the issue of whether establishing consensus standards for the treatment of particular medical conditions increases a physician's exposure to legal liability. The conclusion reached is that the legal effects of standard setting, rather than representing a significant threat of liability, should be seen as beneficial to the medical profession. A fundamental point is that the legal test for liability is entirely dependent on the medical profession's definition of what constitutes adequate care. The law incorporates the standard of care defined by the medical profession and does not impose an external norm. In the absence of formally stated standards, the process of defining relevant medical criteria will involve a great deal of uncertainty. Outcomes of legal contests will be affected by such extraneous factors as the relative experience of the lawyers involved, their access to knowledgeable expert witnesses, and their strategic decisions made with respect to tactics and procedures. Establishment of formal standards has the salutory effect of limiting the influence of these factors and thus reducing the randomness of the results reached. Formal standards also have the advantage of being easily replicated in unrelated proceedings and thereby contribute to the development of a consistent, evenly applied rule of liability. Finally, even if formal standards are either more, or less, progressive than the actual state of medical practice, there is relatively little risk that they will produce untoward results.

  13. 7 CFR 28.107 - Original cotton standards and reserve sets.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Original cotton standards and reserve sets. 28.107... Standards Act Practical Forms of Cotton Standards § 28.107 Original cotton standards and reserve sets. (a) The containers of the original Universal Standards and other official cotton standards of the United...

  14. Occupational standard for exposure to ultraviolet radiation (1989)

    International Nuclear Information System (INIS)

    1989-12-01

    The exposure limit (EL) values in this standard refer to ultraviolet radiation (UVR) in the spectral region between 180 and 400 nm and represents conditions under which it is believed that nearly all workers may be repeatedly exposed without adverse effect. The EL values for exposure of the eye or the skin may be used to evaluate potentially hazardous exposure from UVR. The limits do not apply to ultraviolet lasers. The values should be used as guides in the control of exposure to both pulsed and continuous sources of UVR where the exposure duration is not less than 0.1 μsec. The ELs are below levels used for UV exposures of patients as a part of medical treatment or for elective cosmetic purposes. They are intended as upper limits for non therapeutic and non cosmetic exposure. 2 refs., 2 tabs

  15. Adopting Cut Scores: Post-Standard-Setting Panel Considerations for Decision Makers

    Science.gov (United States)

    Geisinger, Kurt F.; McCormick, Carina M.

    2010-01-01

    Standard-setting studies utilizing procedures such as the Bookmark or Angoff methods are just one component of the complete standard-setting process. Decision makers ultimately must determine what they believe to be the most appropriate standard or cut score to use, employing the input of the standard-setting panelists as one piece of information…

  16. Evaluating OSHA's ethylene oxide standard: exposure determinants in Massachusetts hospitals.

    Science.gov (United States)

    LaMontagne, A D; Kelsey, K T

    2001-03-01

    This study sought to identify determinants of workplace exposures to ethylene oxide to assess the effect of the Occupational Safety and Health Administration's (OSHA's) 1984 ethylene oxide standard. An in-depth survey of all hospitals in Massachusetts that used ethylene oxide from 1990 through 1992 (96% participation, N = 90) was conducted. Three types of exposure events were modeled with logistic regression: exceeding the 8-hour action level, exceeding the 15-minute excursion limit, and worker exposures during unmeasured accidental releases. Covariates were drawn from data representing an ecologic framework including direct and indirect potential exposure determinants. After adjustment for frequencies of ethylene oxide use and exposure monitoring, a significant inverse relation was observed between exceeding the action level and the use of combined sterilizer-aerators, an engineering control technology developed after the passage of the OSHA standard. Conversely, the use of positive-pressure sterilizers that employ ethylene oxide gas mixtures was strongly related to both exceeding the excursion limit and the occurrence of accidental releases. These findings provide evidence of a positive effect of OSHA's ethylene oxide standard and specific targets for future prevention and control efforts.

  17. Microwave radiation - Biological effects and exposure standards

    Energy Technology Data Exchange (ETDEWEB)

    Lindsay, I.R.

    1980-06-01

    The thermal and nonthermal effects of exposure to microwave radiation are discussed and current standards for microwave exposure are examined in light of the proposed use of microwave power transmission from solar power satellites. Effects considered include cataractogenesis at levels above 100 mW/sq cm, and possible reversible disturbances such as headaches, sleeplessness, irritability, fatigue, memory loss, cardiovascular changes and circadian rhythm disturbances at levels less than 10 mW/sq cm. It is pointed out that while the United States and western Europe have adopted exposure standards of 10 mW/sq cm, those adopted in other countries are up to three orders of magnitude more restrictive, as they are based on different principles applied in determining safe limits. Various aspects of the biological effects of microwave transmissions from space are considered in the areas of the protection of personnel working in the vicinity of the rectenna, interactions of the transmitted radiation with cardiac pacemakers, and effects on birds. It is concluded that thresholds for biological effects from short-term microwave radiation are well above the maximal power density of 1 mW/sq cm projected at or beyond the area of exclusion of a rectenna.

  18. Investigating the Decision-Making Process of Standard Setting Participants

    Science.gov (United States)

    Papageorgiou, Spiros

    2010-01-01

    Despite the growing interest of the language testing community in standard setting, primarily due to the use of the Common European Framework of Reference (CEFR-Council of Europe, 2001), the participants' decision-making process in the CEFR standard setting context remains unexplored. This study attempts to fill in this gap by analyzing these…

  19. Features of standardized nursing terminology sets in Japan.

    Science.gov (United States)

    Sagara, Kaoru; Abe, Akinori; Ozaku, Hiromi Itoh; Kuwahara, Noriaki; Kogure, Kiyoshi

    2006-01-01

    This paper reports the features and relationships between standardizes nursing terminology sets used in Japan. First, we analyzed the common parts in five standardized nursing terminology sets: the Japan Nursing Practice Standard Master (JNPSM) that includes the names of nursing activities and is built by the Medical Information Center Development Center (MEDIS-DC); the labels of the Japan Classification of Nursing Practice (JCNP), built by the term advisory committee in the Japan Academy of Nursing Science; the labels of the International Classification for Nursing Practice (ICNP) translated to Japanese; the labels, domain names, and class names of the North American Nursing Diagnosis Association (NANDA) Nursing Diagnoses 2003-2004 translated to Japanese; and the terms included in the labels of Nursing Interventions Classification (NIC) translated to Japanese. Then we compared them with terms in a thesaurus dictionary, the Bunrui Goihyo, that contains general Japanese words and is built by the National Institute for Japanese Language. 1) the level of interchangeability between four standardized nursing terminology sets is quite low; 2) abbreviations and katakana words are frequently used to express nursing activities; 3) general Japanese words are usually used to express the status or situation of patients.

  20. Assessing asbestos exposure potential in nonindustrial settings.

    Science.gov (United States)

    Chang, S N; White, L E; Scott, W D

    1987-01-01

    The presence of asbestos containing materials (ACM) in office and commercial buildings is a significant environmental problem. Asbestosis, mesothelioma and lung cancer have been linked with industrial exposure to airborne asbestos. The extensive use of asbestos products in buildings has raised concerns about the widespread exposure of the general public to asbestos in nonoccupational settings. The presence of asbestos in a building does not necessarily mean that significant exposure of the occupants of the building has occurred, but it is important that the asbestos be monitored regularly to ensure that fibers do not become airborne. If ACM are contained within a matrix and not disturbed, exposure is unlikely. However, if the asbestos becomes friable (crumbling) or if building maintenance, repair, renovation or other activities disturb ACM, airborne asbestos fibers may be a source of exposure to the occupants of the building. Currently, asbestos exposure assessment is conducted by a phase contrast light microscope (PCM) technique. Due to its inherent limitation in resolution and the generic counting rules used, analysis by the PCM method underestimates the airborne asbestos fiber concentration as compared to analysis by transmission electron microscopy (TEM). It is important that the air monitoring results analyzed by PCM be interpreted carefully in conjunction with a survey by a professional to judge the physical condition of the ACM in buildings. Exposure levels to airborne asbestos fibers vary from day to day and depend on the physical condition of the material involved and the type of operating and maintenance program in place.(ABSTRACT TRUNCATED AT 250 WORDS)

  1. Approaches to handling uncertainty when setting environmental exposure standards

    DEFF Research Database (Denmark)

    Budtz-Jørgensen, Esben; Keiding, Niels; Grandjean, Philippe

    2009-01-01

    attempts for the first time to cover the full range of issues related to model uncertainties, from the subjectivity of setting up a conceptual model of a given system, all the way to communicating the nature of model uncertainties to non-scientists and accounting for model uncertainties in policy decisions....... Theoretical chapters, providing background information on specific steps in the modelling process and in the adoption of models by end-users, are complemented by illustrative case studies dealing with soils and global climate change. All the chapters are authored by recognized experts in their respective...

  2. 78 FR 68447 - Exposure Draft-Standards for Internal Control in the Federal Government

    Science.gov (United States)

    2013-11-14

    ... GOVERNMENT ACCOUNTABILITY OFFICE Exposure Draft--Standards for Internal Control in the Federal... revisions to the Standards for Internal Control in the Federal Government, known as the ``Green Book,'' to... proposed changes contained in the 2013 Exposure Draft update to the Standards for Internal Control in the...

  3. Standard setting in medical education: fundamental concepts and emerging challenges.

    Science.gov (United States)

    Mortaz Hejri, Sara; Jalili, Mohammad

    2014-01-01

    The process of determining the minimum pass level to separate the competent students from those who do not perform well enough is called standard setting. A large number of methods are widely used to set cut-scores for both written and clinical examinations. There are some challenging issues pertaining to any standard setting procedure. Ignoring these concerns would result in a large dispute regarding the credibility and defensibility of the method. The goal of this review is to provide a basic understanding of the key concepts and challenges in standard setting and to suggest some recommendations to overcome the challenging issues for educators and policymakers who are dealing with decision-making in this field.

  4. Setting standards to determine core clerkship grades in pediatrics.

    Science.gov (United States)

    Dudas, Robert A; Barone, Michael A

    2014-01-01

    One of the greatest challenges for clerkship directors is assigning a final grade and determining the precise point at which a student either passes or fails a clinical clerkship. The process of incorporating both subjective and objective assessment data to provide a final summative grade can be challenging. We describe our experience conducting a standard-setting exercise to set defensible cut points in a 4-tiered grading system in our pediatric clerkship. Using the Hofstee standard-setting approach, 8 faculty members participated in an exercise to establish grade cut points. These faculty members were subsequently surveyed to assess their attitudes toward the standard-setting process as well as their reactions to these newly proposed standards. We applied the new cut points to a historic cohort of 116 Johns Hopkins University School of Medicine students from the academic year 2012-2013 to assess the potential impact on grade distributions. The resultant grading schema would lead to a significant increase in the number of students receiving a failing grade and a decrease in the number of students receiving a grade of honors in a historical cohort. Faculty reported that the Hofstee method was easy to understand and fair. All faculty members thought that grade inflation presently exists within the pediatric clerkship. This study demonstrates that practical standards using the Hofstee method can be set for medical students in a pediatric clerkship in which multiple performance measures are used. Copyright © 2014 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  5. Earnings Management and Participation in Accounting Standard-Setting

    NARCIS (Netherlands)

    Koenigsgruber, R.; Palan, S.

    2015-01-01

    Recent economic and political science research suggests that the way public policy is set, and in particular the participation of those affected by it, impacts upon the outcome of the policy. Accounting standard setting has long offered such a possibility to participate via the due process approach

  6. Standard Establishment Through Scenarios (SETS): A new technique for occupational fitness standards.

    Science.gov (United States)

    Blacklock, R E; Reilly, T J; Spivock, M; Newton, P S; Olinek, S M

    2015-01-01

    An objective and scientific task analysis provides the basis for establishing legally defensible Physical Employment Standards (PES), based on common and essential occupational tasks. Infrequent performance of these tasks creates challenges when developing PES based on criterion, or content validity. Develop a systematic approach using Subject Matter Experts (SME) to provide tasks with 1) an occupationally relevant scenario considered common to all personnel; 2) a minimum performance standard defined by time, distance, load or work. Examples provided here relate to the development of a new PES for the Canadian Armed Forces (CAF). SME of various experience are selected based on their eligibility criteria. SME are required to define a reasonable scenario for each task from personal experience, provide occupational performance requirements of the scenario in sub-groups, and discuss and agree by consensus vote on the final standard based on the definition of essential. A common and essential task for the CAF is detailed as a case example of process application. Techniques to avoid common SME rating errors are discussed and advantages to the method described. The SETS method was developed as a systematic approach to setting occupational performance standards and qualifying information from SME.

  7. The OSHA hazardous chemical occupational exposure standard for laboratories.

    Science.gov (United States)

    Armbruster, D A

    1991-01-01

    OSHA's chemical occupational exposure standard for laboratories is an outgrowth of the previously issued Hazard Communication Standard. The standard relieves laboratories from complying with general industry standards but does require compliance with specific laboratory guidelines. The heart of the standard is the creation of a Chemical Hygiene Plan (CHP). The CHP addresses major issues such as safety equipment and procedures, work practices, training, the designation of a chemical hygiene officer, and the provision of medical consultation and examination for affected employees. This new standard, in full effect as of January 31, 1991, presents yet another regulatory challenge to laboratory managers but also ensures a safer environment for laboratory workers.

  8. The primary exposure standard for Co-60 gamma radiation: characteristics and measurements procedures

    International Nuclear Information System (INIS)

    Laitano, R.F.; Toni, M.P.

    1983-01-01

    A description is given of a cavity ionization chamber used, as a primary exposure standard, at the Laboratorio di Metrologia delle Radiazioni Ionizzanti of the ENEA in Italy. The primary standard is designed to make absolute measurements of exposure due to the Co-60 gamma radiation. The procedures for the realizationof the exposure unit are also described. Finally results of some international comparisons are reported

  9. Setting the bar: Standards for ecosystem services

    CSIR Research Space (South Africa)

    Polasky, S

    2015-06-01

    Full Text Available to specific use contexts, such as national income and wealth accounts, corporate sustainability reporting, land-use planning, and environmental impact assessments. Many standard-setting organizations already exist, and the research community will make the most...

  10. Using PISA as an International Benchmark in Standard Setting.

    Science.gov (United States)

    Phillips, Gary W; Jiang, Tao

    2015-01-01

    This study describes how the Programme for International Student Assessment (PISA) can be used to internationally benchmark state performance standards. The process is accomplished in three steps. First, PISA items are embedded in the administration of the state assessment and calibrated on the state scale. Second, the international item calibrations are then used to link the state scale to the PISA scale through common item linking. Third, the statistical linking results are used as part of the state standard setting process to help standard setting panelists determine how high their state standards need to be in order to be internationally competitive. This process was carried out in Delaware, Hawaii, and Oregon, in three subjects-science, mathematics and reading with initial results reported by Phillips and Jiang (2011). An in depth discussion of methods and results are reported in this article for one subject (mathematics) and one state (Hawaii).

  11. Science and trans-science in standard setting

    International Nuclear Information System (INIS)

    Majone, G.

    1984-01-01

    Standard-setting is a blending of scientific, trans-scientific, and political elements which result in a number of consequences. Health standards, for example, are influenced by biological and philosophical assumptions and scientific traditions, with the dose-response function treated as a trans-scientific question because of scientific uncertainties. Costs and benefits and other values besides health, safety, or environment also enter into the balancing of regulatory decisions and keep regulations from a purely scientific knowledge is desirable. Recommendations that industry be self-regulatory reflect a shift in emphasis from legal enforcement to information-based compliance

  12. Radiological error: analysis, standard setting, targeted instruction and teamworking

    International Nuclear Information System (INIS)

    FitzGerald, Richard

    2005-01-01

    Diagnostic radiology does not have objective benchmarks for acceptable levels of missed diagnoses [1]. Until now, data collection of radiological discrepancies has been very time consuming. The culture within the specialty did not encourage it. However, public concern about patient safety is increasing. There have been recent innovations in compiling radiological interpretive discrepancy rates which may facilitate radiological standard setting. However standard setting alone will not optimise radiologists' performance or patient safety. We must use these new techniques in radiological discrepancy detection to stimulate greater knowledge sharing, targeted instruction and teamworking among radiologists. Not all radiological discrepancies are errors. Radiological discrepancy programmes must not be abused as an instrument for discrediting individual radiologists. Discrepancy rates must not be distorted as a weapon in turf battles. Radiological errors may be due to many causes and are often multifactorial. A systems approach to radiological error is required. Meaningful analysis of radiological discrepancies and errors is challenging. Valid standard setting will take time. Meanwhile, we need to develop top-up training, mentoring and rehabilitation programmes. (orig.)

  13. Science and art of setting performance standards and cutoff scores in kinesiology.

    Science.gov (United States)

    Zhu, Weimo

    2013-12-01

    Setting standards and cutoff scores is essential to any measurement and evaluation practice. Two evaluation frameworks, norm-referenced (NR) and criterion-referenced (CR), have often been used for setting standards. Although setting fitness standards based on the NR evaluation is relatively easy as long as a nationally representative sample can be obtained and regularly updated, it has several limitations-namely, time dependency, population dependence, discouraging low-level performers, and favoring advantaged or punishing disadvantaged individuals. Fortunately, these limitations can be significantly eliminated by employing the CR evaluation, which was introduced to kinesiology by Safrit and colleagues in the 1980s and has been successfully applied to some practical problems (e.g., set health-related fitness standards for FITNESSGRAM). Yet, the CR evaluation has its own challenges, e.g., selecting an appropriate measure for a criterion behavior, when the expected relationship between the criterion behavior and a predictive measure is not clear, and when standards are not consistent among multiple field measures. Some of these challenges can be addressed by employing the latest statistical methods (e.g., test equating). This article provides a comprehensive review of the science and art of setting standards and cutoff scores in kinesiology. After a brief historical overview of the standard-setting practice in kinesiology is presented, a case analysis of a successful CR evaluation, along with related challenges, is described. Lessons learned from past and current practice as well as how to develop a defendable standard are described. Finally, future research needs and directions are outlined.

  14. International Review of Frameworks for Standard Setting & Labeling Development

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Nan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Khanna, Nina Zheng [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Fridley, David [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Romankiewicz, John [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-09-01

    As appliance energy efficiency standards and labeling (S&L) programs reach a broader geographic and product scope, a series of sophisticated and complex technical and economic analyses have been adopted by different countries in the world to support and enhance these growing S&L programs. The initial supporting techno-economic and impact analyses for S&L development make up a defined framework and process for setting and developing appropriate appliance efficiency standards and labeling programs. This report reviews in-depth the existing framework for standards setting and label development in the well-established programs of the U.S., Australia and the EU to identify and evaluate major trends in how and why key analyses are undertaken and to understand major similarities and differences between each of the frameworks.

  15. Standard Setting for the Extractive Industries: A Critical Examination

    Directory of Open Access Journals (Sweden)

    Corinne Cortese

    2007-09-01

    Full Text Available This study examines the players involved in the setting of an international accountingstandard for the extractive industries. Publicly available data is used to exposeconnections between key constituents involved in the process, to enhance understandingof how the international accounting standard setting process occurred, and to identifyfuture research possibilities.

  16. Influences of large sets of environmental exposures on immune responses in healthy adult men.

    Science.gov (United States)

    Yi, Buqing; Rykova, Marina; Jäger, Gundula; Feuerecker, Matthias; Hörl, Marion; Matzel, Sandra; Ponomarev, Sergey; Vassilieva, Galina; Nichiporuk, Igor; Choukèr, Alexander

    2015-08-26

    Environmental factors have long been known to influence immune responses. In particular, clinical studies about the association between migration and increased risk of atopy/asthma have provided important information on the role of migration associated large sets of environmental exposures in the development of allergic diseases. However, investigations about environmental effects on immune responses are mostly limited in candidate environmental exposures, such as air pollution. The influences of large sets of environmental exposures on immune responses are still largely unknown. A simulated 520-d Mars mission provided an opportunity to investigate this topic. Six healthy males lived in a closed habitat simulating a spacecraft for 520 days. When they exited their "spacecraft" after the mission, the scenario was similar to that of migration, involving exposure to a new set of environmental pollutants and allergens. We measured multiple immune parameters with blood samples at chosen time points after the mission. At the early adaptation stage, highly enhanced cytokine responses were observed upon ex vivo antigen stimulations. For cell population frequencies, we found the subjects displayed increased neutrophils. These results may presumably represent the immune changes occurred in healthy humans when migrating, indicating that large sets of environmental exposures may trigger aberrant immune activity.

  17. State Standard-Setting Processes in Brief. State Academic Standards: Standard-Setting Processes

    Science.gov (United States)

    Thomsen, Jennifer

    2014-01-01

    Concerns about academic standards, whether created by states from scratch or adopted by states under the Common Core State Standards (CCSS) banner, have drawn widespread media attention and are at the top of many state policymakers' priority lists. Recently, a number of legislatures have required additional steps, such as waiting periods for…

  18. UV dose-effect relationships and current protection exposure standards

    International Nuclear Information System (INIS)

    Singh, M.S.; Campbell, G.W.

    1982-04-01

    In this paper we have attempted to quantify the health effects in man of uv-radiation exposure of wavelengths from 240 nm to 320 nm. Exposure to uv in this region could result in the formation of skin cancer or premature aging in man. The induction of cancer by uv radiation results from changes in genetic material. We have used the DNA action spectrum coupled with the uv skin cancer data available in the literature to derive the dose-effect relationships. The results are compared against the current uv protection standards

  19. Core Outcome Set-STAndards for Development: The COS-STAD recommendations.

    Directory of Open Access Journals (Sweden)

    Jamie J Kirkham

    2017-11-01

    Full Text Available The use of core outcome sets (COS ensures that researchers measure and report those outcomes that are most likely to be relevant to users of their research. Several hundred COS projects have been systematically identified to date, but there has been no formal quality assessment of these studies. The Core Outcome Set-STAndards for Development (COS-STAD project aimed to identify minimum standards for the design of a COS study agreed upon by an international group, while other specific guidance exists for the final reporting of COS development studies (Core Outcome Set-STAndards for Reporting [COS-STAR].An international group of experienced COS developers, methodologists, journal editors, potential users of COS (clinical trialists, systematic reviewers, and clinical guideline developers, and patient representatives produced the COS-STAD recommendations to help improve the quality of COS development and support the assessment of whether a COS had been developed using a reasonable approach. An open survey of experts generated an initial list of items, which was refined by a 2-round Delphi survey involving nearly 250 participants representing key stakeholder groups. Participants assigned importance ratings for each item using a 1-9 scale. Consensus that an item should be included in the set of minimum standards was defined as at least 70% of the voting participants from each stakeholder group providing a score between 7 and 9. The Delphi survey was followed by a consensus discussion with the study management group representing multiple stakeholder groups. COS-STAD contains 11 minimum standards that are the minimum design recommendations for all COS development projects. The recommendations focus on 3 key domains: the scope, the stakeholders, and the consensus process.The COS-STAD project has established 11 minimum standards to be followed by COS developers when planning their projects and by users when deciding whether a COS has been developed using

  20. Core Outcome Set-STAndards for Development: The COS-STAD recommendations.

    Science.gov (United States)

    Kirkham, Jamie J; Davis, Katherine; Altman, Douglas G; Blazeby, Jane M; Clarke, Mike; Tunis, Sean; Williamson, Paula R

    2017-11-01

    The use of core outcome sets (COS) ensures that researchers measure and report those outcomes that are most likely to be relevant to users of their research. Several hundred COS projects have been systematically identified to date, but there has been no formal quality assessment of these studies. The Core Outcome Set-STAndards for Development (COS-STAD) project aimed to identify minimum standards for the design of a COS study agreed upon by an international group, while other specific guidance exists for the final reporting of COS development studies (Core Outcome Set-STAndards for Reporting [COS-STAR]). An international group of experienced COS developers, methodologists, journal editors, potential users of COS (clinical trialists, systematic reviewers, and clinical guideline developers), and patient representatives produced the COS-STAD recommendations to help improve the quality of COS development and support the assessment of whether a COS had been developed using a reasonable approach. An open survey of experts generated an initial list of items, which was refined by a 2-round Delphi survey involving nearly 250 participants representing key stakeholder groups. Participants assigned importance ratings for each item using a 1-9 scale. Consensus that an item should be included in the set of minimum standards was defined as at least 70% of the voting participants from each stakeholder group providing a score between 7 and 9. The Delphi survey was followed by a consensus discussion with the study management group representing multiple stakeholder groups. COS-STAD contains 11 minimum standards that are the minimum design recommendations for all COS development projects. The recommendations focus on 3 key domains: the scope, the stakeholders, and the consensus process. The COS-STAD project has established 11 minimum standards to be followed by COS developers when planning their projects and by users when deciding whether a COS has been developed using reasonable

  1. American National Standard: nuclear data sets for reactor design calculations

    International Nuclear Information System (INIS)

    1983-01-01

    This standard identifies and describes the specifications for developing, preparing, and documenting nuclear data sets to be used in reactor design calculations. The specifications include criteria for acceptance of evaluated nuclear data sets, criteria for processing evaluated data and preparation of processed continuous data and averaged data sets, and identification of specific evaluated, processed continuous, and averaged data sets which meet these criteria for specific reactor types

  2. Setting standards and detecting intrajudge inconsistency using interdependent evaluation of response alternatives

    NARCIS (Netherlands)

    Chang, Lei; van der Linden, Willem J.; Vos, Hendrik J.

    2004-01-01

    This article introduces a new test-centered standard-setting method as well as a procedure to detect intrajudge inconsistency of the method. The standard-setting method that is based on interdependent evaluations of alternative responses has judges closely evaluate the process that examinees use to

  3. American National Standard nuclear data sets for reactor design calculations

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    A standard is presented which identifies and describes the specifications for developing, preparing, and documenting nuclear data sets to be used in reactor design calculations. The specifications include (a) criteria for acceptance of evaluated nuclear data sets, (b) criteria for processing evaluated data and preparation of processed continuous data and averaged data sets, and (c) identification of specific evaluated, processed continuous, and averaged data sets which meet these criteria for specific reactor types

  4. Explanation of nurse standard of external exposure acute radiation sickness

    International Nuclear Information System (INIS)

    Lu Xiuling; Jiang Enhai; Sun Feifei; Zhang Bin; Wang Xiaoguang; Wang Guilin

    2012-01-01

    National occupational health standard-Nurse Standard of External Exposure Acute Radiation Sickness has been approved and issued by the Ministry of Health. Based on the extensive research of literature, collection of the previous nuclear and radiation accidents excessive exposed personnel data and specific situations in China, this standard was enacted according to the current national laws, regulations, and the opinions of peer experts. It is mainly used for care of patients with acute radiation sickness, and also has directive significance for care of patients with iatrogenic acute radiation sickness which due to the hematopoietic stem cell transplantation pretreatment. To correctly carry out this standard and to reasonably implement nursing measures for patients with acute radiation sickness, the contents of this standard were interpreted in this article. (authors)

  5. Implementation of a primary standard for x-ray exposure

    International Nuclear Information System (INIS)

    Peixoto, Jose Guilherme Pereira

    1991-04-01

    In the scientific program of the National Laboratory for Ionizing Radiation Metrology of the Instituto de Radioprotecao e Dosimetria, which belongs to the Comissao Nacional de Energia Nuclear, a free-air ionization chamber should be established as an exposure primary standard for X-ray s of 10OKV to 250kV of potential range. Preliminary results showed that the available free-air ionization chamber was suitable to be used. The absolute measurement of the radiation quantity exposure, is performed with a free-air ionization chamber. Its geometrical volume, which allows the determination of the air mass, is defined by the effective aperture area and by the length of the region where an electrical field is applied. Most of the ions produced in such volume are collected as an ionization current. Since the collecting rod is small, and positioned far away from the X-ray beam, only a negligible fraction of ionization (0,01 %) is lost due to interactions with it. Parameters related to the measurement of the quantity exposure were evaluated, such as: air absorption, scattering inside the ionization chamber, saturation , beam homogeneity, influence Of beam size and influences of temperature, humidity and atmospheric pressure.Preliminary determination of correction factors has showed good results with 99.9% of repeatability and has demonstrated the reliability of the checked chamber as a standard instrument. (author)

  6. Implementation of a primary standard for a x-ray exposure

    International Nuclear Information System (INIS)

    peixoto, J.G.P.

    1991-04-01

    In the scientific program of the National Laboratory for Ionizing Radiation Metrology of the Instituto de Radioprotecao e Dosimetria, which belongs to the Comissao Nacional de Energia Nuclear, a free-air ionization chamber should be established as an exposure primary standard for X-rays of 100 K V to 250 K V of potential range. Preliminary results showed that the available free-air ionization chamber was suitable to be used. The absolute measurement of the radiation quantity exposure, is performed with a free-air ionization chamber. Its geometrical volume, which allows the determination of the air mass, is defined by the effective aperture area and by the length of the region where an electrical field is applied. Most of the ions produced in such volume are collected as an ionization current. Parameters related to the measurement of the quantity exposure were evaluated, such as: air absorption, scattering inside the ionization chamber, saturation, beam homogeneity, influence of beam size and influences of temperature, humidity and atmospheric pressure. Preliminary determination of correction factors has showed good results with 99.9% of repeatability and has demonstrated the reliability of the checked chamber as a standard instrument. (author)

  7. Research on Standard and Automatic Judgment of Press-fit Curve of Locomotive Wheel-set Based on AAR Standard

    Science.gov (United States)

    Lu, Jun; Xiao, Jun; Gao, Dong Jun; Zong, Shu Yu; Li, Zhu

    2018-03-01

    In the production of the Association of American Railroads (AAR) locomotive wheel-set, the press-fit curve is the most important basis for the reliability of wheel-set assembly. In the past, Most of production enterprises mainly use artificial detection methods to determine the quality of assembly. There are cases of miscarriage of justice appear. For this reason, the research on the standard is carried out. And the automatic judgment of press-fit curve is analysed and designed, so as to provide guidance for the locomotive wheel-set production based on AAR standard.

  8. The Role of Construct Maps in Standard Setting

    Science.gov (United States)

    Kane, Michael T.; Tannenbaum, Richard J.

    2013-01-01

    The authors observe in this commentary that construct maps can help standard-setting panels to make realistic and internally consistent recommendations for performance-level descriptions (PLDs) and cut-scores, but the benefits may not be realized if policymakers do not fully understand the rationale for the recommendations provided by the…

  9. Application of physiologically based pharmacokinetic modeling in setting acute exposure guideline levels for methylene chloride.

    NARCIS (Netherlands)

    Bos, Peter Martinus Jozef; Zeilmaker, Marco Jacob; Eijkeren, Jan Cornelis Henri van

    2006-01-01

    Acute exposure guideline levels (AEGLs) are derived to protect the human population from adverse health effects in case of single exposure due to an accidental release of chemicals into the atmosphere. AEGLs are set at three different levels of increasing toxicity for exposure durations ranging from

  10. Setting the bar: Standards for ecosystem services.

    Science.gov (United States)

    Polasky, Stephen; Tallis, Heather; Reyers, Belinda

    2015-06-16

    Progress in ecosystem service science has been rapid, and there is now a healthy appetite among key public and private sector decision makers for this science. However, changing policy and management is a long-term project, one that raises a number of specific practical challenges. One impediment to broad adoption of ecosystem service information is the lack of standards that define terminology, acceptable data and methods, and reporting requirements. Ecosystem service standards should be tailored to specific use contexts, such as national income and wealth accounts, corporate sustainability reporting, land-use planning, and environmental impact assessments. Many standard-setting organizations already exist, and the research community will make the most headway toward rapid uptake of ecosystem service science by working directly with these organizations. Progress has been made in aligning with existing organizations in areas such as product certification and sustainability reporting, but a major challenge remains in mainstreaming ecosystem service information into core public and private use contexts, such as agricultural and energy subsidy design, national income accounts, and corporate accounts.

  11. Setting the bar: Standards for ecosystem services

    Science.gov (United States)

    Polasky, Stephen; Tallis, Heather; Reyers, Belinda

    2015-01-01

    Progress in ecosystem service science has been rapid, and there is now a healthy appetite among key public and private sector decision makers for this science. However, changing policy and management is a long-term project, one that raises a number of specific practical challenges. One impediment to broad adoption of ecosystem service information is the lack of standards that define terminology, acceptable data and methods, and reporting requirements. Ecosystem service standards should be tailored to specific use contexts, such as national income and wealth accounts, corporate sustainability reporting, land-use planning, and environmental impact assessments. Many standard-setting organizations already exist, and the research community will make the most headway toward rapid uptake of ecosystem service science by working directly with these organizations. Progress has been made in aligning with existing organizations in areas such as product certification and sustainability reporting, but a major challenge remains in mainstreaming ecosystem service information into core public and private use contexts, such as agricultural and energy subsidy design, national income accounts, and corporate accounts. PMID:26082540

  12. Setting Standards and Primary School Teachers' Experiences of the Process

    Science.gov (United States)

    Scherman, Vanessa; Zimmerman, Lisa; Howie, Sarah J.; Bosker, Roel

    2014-01-01

    In South Africa, very few standard-setting exercises are carried out in education and, if they are, teachers are not involved in their execution. As a result, there is no clear understanding of what the standard is and how it was arrived at. This situation is compounded when teachers are held accountable when learners do not meet the prescribed…

  13. Power battles in ICT standards-setting process : lessons from mobile payments

    NARCIS (Netherlands)

    Lim, A.S.

    2006-01-01

    Standards play an important role in ICT innovation to ensure the interoperability and interconnectivity. However, standardisation is a complex process that involves actors with different interests. Various studies, which are mainly economics, have tried to develop the standards-setting process

  14. A primer on standards setting as it applies to surgical education and credentialing.

    Science.gov (United States)

    Cendan, Juan; Wier, Daryl; Behrns, Kevin

    2013-07-01

    Surgical technological advances in the past three decades have led to dramatic reductions in the morbidity associated with abdominal procedures and permanently altered the surgical practice landscape. Significant changes continue apace including surgical robotics, natural orifice-based surgery, and single-incision approaches. These disruptive technologies have on occasion been injurious to patients, and high-stakes assessment before adoption of new technologies would be reasonable. We reviewed the drivers for well-established psychometric techniques available for the standards-setting process. We present a series of examples that are relevant in the surgical domain including standards setting for knowledge and skills assessments. Defensible standards for knowledge and procedural skills will likely become part of surgical clinical practice. Understanding the methodology for determining standards should position the surgical community to assist in the process and lead within their clinical settings as standards are considered that may affect patient safety and physician credentialing.

  15. Toward analytic aids for standard setting in nuclear regulation

    International Nuclear Information System (INIS)

    Brown, R.V.; O'Connor, M.F.; Peterson, C.R.

    1979-05-01

    US NRC promulgates standards for nuclear reprocessing and other facilities to safeguard against the diversion of nuclear material. Two broad tasks have been directed toward establishing performance criteria for standard settings: general-purpose modeling, and analysis specific to a particular performance criterion option. This report emphasizes work on the second task. Purpose is to provide a framework for the evaluation of such options that organizes the necessary components in a way that provides for meaningful assessments with respect to required inputs

  16. Automatic exposure control at single- and dual-heartbeat CTCA on a 320-MDCT volume scanner: effect of heart rate, exposure phase window setting, and reconstruction algorithm.

    Science.gov (United States)

    Funama, Yoshinori; Utsunomiya, Daisuke; Taguchi, Katsuyuki; Oda, Seitaro; Shimonobo, Toshiaki; Yamashita, Yasuyuki

    2014-05-01

    To investigate whether electrocardiogram (ECG)-gated single- and dual-heartbeat computed tomography coronary angiography (CTCA) with automatic exposure control (AEC) yields images with uniform image noise at reduced radiation doses. Using an anthropomorphic chest CT phantom we performed prospectively ECG-gated single- and dual-heartbeat CTCA on a second-generation 320-multidetector CT volume scanner. The exposure phase window was set at 75%, 70-80%, 40-80%, and 0-100% and the heart rate at 60 or 80 or corr80 bpm; images were reconstructed with filtered back projection (FBP) or iterative reconstruction (IR, adaptive iterative dose reduction 3D). We applied AEC and set the image noise level to 20 or 25 HU. For each technique we determined the image noise and the radiation dose to the phantom center. With half-scan reconstruction at 60 bpm, a 70-80% phase window- and a 20-HU standard deviation (SD) setting, the imagenoise level and -variation along the z axis manifested similar curves with FBP and IR. With half-scan reconstruction, the radiation dose to the phantom center with 70-80% phase window was 18.89 and 12.34 mGy for FBP and 4.61 and 3.10 mGy for IR at an SD setting SD of 20 and 25 HU, respectively. At 80 bpm with two-segment reconstruction the dose was approximately twice that of 60 bpm at both SD settings. However, increasing radiation dose at corr80 bpm was suppressed to 1.39 times compared to 60 bpm. AEC at ECG-gated single- and dual-heartbeat CTCA controls the image noise at different radiation dose. Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  17. Developing Archive Information Packages for Data Sets: Early Experiments with Digital Library Standards

    Science.gov (United States)

    Duerr, R. E.; Yang, M.; Gooyabadi, M.; Lee, C.

    2008-12-01

    The key to interoperability between systems is often metadata, yet metadata standards in the digital library and data center communities have evolved separately. In the data center world NASA's Directory Interchange Format (DIF), the Content Standard for Digital Geospatial Metadata (CSDGM), and most recently the international Geographic Information: Metadata (ISO 19115:2003) are used for descriptive metadata at the data set level to allow catalog interoperability; but use of anything other than repository- based metadata standards for the individual files that comprise a data set is rare, making true interoperability, at the data rather than data set level, across archives difficult. While the Open Archival Information Systems (OAIS) Reference Model with its call for creating Archive Information Packages (AIP) containing not just descriptive metadata but also preservation metadata is slowly being adopted in the community, the PREservation Metadata Implementation Strategies (PREMIS) standard, the only extant OAIS- compliant preservation metadata standard, has scarcely even been recognized as being applicable to the community. The digital library community in the meantime has converged upon the Metadata Encoding and Transmission Standard (METS) for interoperability between systems as evidenced by support for the standard by digital library systems such as Fedora and Greenstone. METS is designed to allow inclusion of other XML-based standards as descriptive and administrative metadata components. A recent Stanford study suggests that a combination of METS with included FGDC and PREMIS metadata could work well for individual granules of a data set. However, some of the lessons learned by the data center community over the last 30+ years of dealing with digital data are 1) that data sets as a whole need to be preserved and described and 2) that discovery and access mechanisms need to be hierarchical. Only once a user has reviewed a data set description and determined

  18. Setting Standards for Medically-Based Running Analysis

    Science.gov (United States)

    Vincent, Heather K.; Herman, Daniel C.; Lear-Barnes, Leslie; Barnes, Robert; Chen, Cong; Greenberg, Scott; Vincent, Kevin R.

    2015-01-01

    Setting standards for medically based running analyses is necessary to ensure that runners receive a high-quality service from practitioners. Medical and training history, physical and functional tests, and motion analysis of running at self-selected and faster speeds are key features of a comprehensive analysis. Self-reported history and movement symmetry are critical factors that require follow-up therapy or long-term management. Pain or injury is typically the result of a functional deficit above or below the site along the kinematic chain. PMID:25014394

  19. Transportable GPU (General Processor Units) chip set technology for standard computer architectures

    Science.gov (United States)

    Fosdick, R. E.; Denison, H. C.

    1982-11-01

    The USAFR-developed GPU Chip Set has been utilized by Tracor to implement both USAF and Navy Standard 16-Bit Airborne Computer Architectures. Both configurations are currently being delivered into DOD full-scale development programs. Leadless Hermetic Chip Carrier packaging has facilitated implementation of both architectures on single 41/2 x 5 substrates. The CMOS and CMOS/SOS implementations of the GPU Chip Set have allowed both CPU implementations to use less than 3 watts of power each. Recent efforts by Tracor for USAF have included the definition of a next-generation GPU Chip Set that will retain the application-proven architecture of the current chip set while offering the added cost advantages of transportability across ISO-CMOS and CMOS/SOS processes and across numerous semiconductor manufacturers using a newly-defined set of common design rules. The Enhanced GPU Chip Set will increase speed by an approximate factor of 3 while significantly reducing chip counts and costs of standard CPU implementations.

  20. The role of Health Impact Assessment in the setting of air quality standards: An Australian perspective

    Energy Technology Data Exchange (ETDEWEB)

    Spickett, Jeffery, E-mail: J.Spickett@curtin.edu.au [WHO Collaborating Centre for Environmental Health Impact Assessment (Australia); Faculty of Health Sciences, School of Public Health, Curtin University, Perth, Western Australia (Australia); Katscherian, Dianne [WHO Collaborating Centre for Environmental Health Impact Assessment (Australia); Faculty of Health Sciences, School of Public Health, Curtin University, Perth, Western Australia (Australia); Harris, Patrick [CHETRE — UNSW Research Centre for Primary Health Care and Equity, University of New South Wales (Australia)

    2013-11-15

    The approaches used for setting or reviewing air quality standards vary from country to country. The purpose of this research was to consider the potential to improve decision-making through integration of HIA into the processes to review and set air quality standards used in Australia. To assess the value of HIA in this policy process, its strengths and weaknesses were evaluated aligned with review of international processes for setting air quality standards. Air quality standard setting programmes elsewhere have either used HIA or have amalgamated and incorporated factors normally found within HIA frameworks. They clearly demonstrate the value of a formalised HIA process for setting air quality standards in Australia. The following elements should be taken into consideration when using HIA in standard setting. (a) The adequacy of a mainly technical approach in current standard setting procedures to consider social determinants of health. (b) The importance of risk assessment criteria and information within the HIA process. The assessment of risk should consider equity, the distribution of variations in air quality in different locations and the potential impacts on health. (c) The uncertainties in extrapolating evidence from one population to another or to subpopulations, especially the more vulnerable, due to differing environmental factors and population variables. (d) The significance of communication with all potential stakeholders on issues associated with the management of air quality. In Australia there is also an opportunity for HIA to be used in conjunction with the NEPM to develop local air quality standard measures. The outcomes of this research indicated that the use of HIA for air quality standard setting at the national and local levels would prove advantageous. -- Highlights: • Health Impact Assessment framework has been applied to a policy development process. • HIA process was evaluated for application in air quality standard setting.

  1. Standard setting in the teaching and learning process in the Kenya ...

    African Journals Online (AJOL)

    Standards are set at different levels to govern different requirements that collectively add up to the ingredients of quality education of a child. This study investigated whether or not there are quantitative standards of achievement for guiding teaching and learning in the school system in Kenya. It also investigated teachers' ...

  2. Humidity correction in the standard measurement of exposure

    International Nuclear Information System (INIS)

    Ibaraki, Yasuyuki; Katoh, Akira

    1980-01-01

    This paper deals with the humidity correction to be made in the standard measurement of the exposure to the measured ionization current in the humid air for the purpose of excluding the influence of the water vapour that is not included in the definition of the exposure. First, formulae giving the humidity correction factors for a parallel plate free air chamber and a cavity chamber have been derived respectively in the case where the contributions of air and water vapour to the ionization are independent. Next, in the case where the contributions are not independent, i.e., the Jesse effect is taken into account, a formula to obtain the W-value for humid air has been derived on the basis of the Niatel's experimental result. Using this formula, formulae to obtain the humidity correction factors for the free air chamber and the cavity chamber are derived. The humidity calculated by the latter formulae show good agreements with the results by Niatel and Guiho, respectively. (author)

  3. Standard setting and quality of assessment: A conceptual approach ...

    African Journals Online (AJOL)

    Quality performance standards and the effect of assessment outcomes are important in the educational milieu, as assessment remains the representative ... not be seen as a methodological process of setting pass/fail cut-off points only, but as a powerful catalyst for quality improvements in HPE by promoting excellence in ...

  4. Global rule-setting for business: A critical analysis of multi-stakeholder standards

    NARCIS (Netherlands)

    Fransen, L.W.; Kolk, A.

    2007-01-01

    In the field of global rule-setting for responsible business behaviour, multi-stakeholder standards have emerged in recent years because of their potential for effective consensus-building, knowledgesharing and interest representation. Proponents also hold that multistakeholder standards could

  5. Volatility Exposure for Strategic Asset Allocation

    OpenAIRE

    Briere, Marie; Burgues, Alexandre; Signori, Ombretta

    2008-01-01

    This paper examines the advantages of incorporating strategic exposure to equity volatility into the investment-opportunity set of a long-term equity investor. We consider two standard volatility investments: implied volatility and volatility risk premium strategies. To calibrate and assess the risk/return profile of the portfolio, we present an analytical framework offering pragmatic solutions for long-term investors seeking exposure to volatility. The benefit of volatility exposure for a co...

  6. Radiation safety standards: space hazards vs. terrestrial hazards

    International Nuclear Information System (INIS)

    Sinclair, W.K.

    1983-01-01

    Policies regarding the setting of standards for radiation exposure for astronauts and other workers in space are discussed. The first recommendations for dose limitation and the underlying philosophy of these recommendations, which were put out in 1970, are examined, and consequences for the standards if the same philosophy of allowing a doubling in overall cancer risk for males aged 30-35 over a 20-year period were applied to more recent risk estimates are calculated, leading to values about a factor of 4 below the 1970 recommendation. Standards set since 1930 for terrestrial occupational exposures, which lead to a maximum lifetime risk of about 2.3 percent, are then considered, and the space and terrestrial exposure risks for fatal cancers at maximum lifetime dose are compared with industrial accidental death rates. Attention is also given to the question of the potential effects of HZE particles in space and to the possibility that HZE particle effects, rather than radiation carcinogenesis, might be the limiting factor. 17 references

  7. Risk approaches in setting radiation standards

    International Nuclear Information System (INIS)

    Whipple, C.

    1984-01-01

    This paper discusses efforts to increase the similarity of risk regulation approaches for radiation and chemical carcinogens. The risk assessment process in both cases involves the same controversy over the extrapolation from high to low doses and dose rates, and in both cases the boundaries between science and policy in risk assessment are indistinct. Three basic considerations are presented to approach policy questions: the economic efficiency of the regulatory approach, the degree of residual risk, and the technical opportunities for risk control. It is the author's opinion that if an agency can show that its standard-setting policies are consistent with those which have achieved political and judicial acceptance in other contexts, the greater the predictability of the regulatory process and the stability of this process

  8. Determining a Consistent Set of Accounting and Financial Reporting Standards

    OpenAIRE

    Anne Le Manh-Béna; Olivier Ramond

    2011-01-01

    Following the debate on the Conceptual Framework revision undertaken by the IASB and the FASB, this paper discusses three major concerns about the way financial reporting standards should be determined: (1) What is the role a Conceptual Framework?; (2) For whom and for which needs are accounting and financial reporting standards made?; and (3) What information set should financial reporting provide? We show that the perceived need of a Framework has resulted in practice in weak usefulness We ...

  9. The 1997 determination of the Australian standards of exposure and absorbed dose at 60Co

    International Nuclear Information System (INIS)

    Huntley, R.B.; Boas, J.F.; Van der Gaast, H.

    1998-05-01

    The arrangements for the maintenance of the Australian standards for 60 Co are described in detail. The primary standards are a graphite cavity chamber for exposure/air kerma and a graphite calorimeter for absorbed dose. These secondary standards are described and their responses in corresponding 90 Sr reference sources are reported. Accurate ratios between the Australian Radiation Laboratory (ARL) and Australian Nuclear Science and Technology (ANSTO) 90 Sr reference sources are derived for use in future calibrations. The value of 28.8 years for the half-life of 90 Sr is confirmed. The usefulness of 90 Sr reference source measurements in quality assurance is discussed. The charge sensitivity and linearity of the ANSTO electrometers are reported by two different methods and are compared with previous results. Calibration factors for all the secondary standard ionization chambers are given, in terms of exposure, air kerma and absorbed dose to water. Calibration factors are also given for most of the chambers in terms of absorbed dose to graphite. The methods of deriving the calibration factors are explained in detail, including all the corrections applied to both the primary and secondary standard measurements. Three alternative methods of deriving the absorbed dose to water calibration factors are compared. The reported calibration factors are compared with previous results. Changes in the Australian units of exposure, air kerma and absorbed dose to graphite and water are derived from changes in the corresponding calibration factors. The Australian units of exposure and air kerma have not changed significantly since 1990. The Australian unit of absorbed dose to graphite is now 1.1 % smaller than in 1993 and 1.3 % smaller than in 1990. The Australian unit of absorbed dose to water is now 1.4 % smaller than in 1993, but is only 0.9 % smaller than in 1990. Comparisons of the Australian standards of exposure/air kerma and absorbed dose with those of the Bureau

  10. Basic Laparoscopic Skills Assessment Study: Validation and Standard Setting among Canadian Urology Trainees.

    Science.gov (United States)

    Lee, Jason Y; Andonian, Sero; Pace, Kenneth T; Grober, Ethan

    2017-06-01

    As urology training programs move to a competency based medical education model, iterative assessments with objective standards will be required. To develop a valid set of technical skills standards we initiated a national skills assessment study focusing initially on laparoscopic skills. Between February 2014 and March 2016 the basic laparoscopic skill of Canadian urology trainees and attending urologists was assessed using 4 standardized tasks from the AUA (American Urological Association) BLUS (Basic Laparoscopic Urological Surgery) curriculum, including peg transfer, pattern cutting, suturing and knot tying, and vascular clip applying. All performances were video recorded and assessed using 3 methods, including time and error based scoring, expert global rating scores and C-SATS (Crowd-Sourced Assessments of Technical Skill Global Rating Scale), a novel, crowd sourced assessment platform. Different methods of standard setting were used to develop pass-fail cut points. Six attending urologists and 99 trainees completed testing. Reported laparoscopic experience and training level correlated with performance (p standard setting methods to define pass-fail cut points for all 4 AUA BLUS tasks. The 4 AUA BLUS tasks demonstrated good construct validity evidence for use in assessing basic laparoscopic skill. Performance scores using the novel C-SATS platform correlated well with traditional time-consuming methods of assessment. Various standard setting methods were used to develop pass-fail cut points for educators to use when making formative and summative assessments of basic laparoscopic skill. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  11. Report on the Observance of Standards and Codes, Accounting and Auditing : Module B - Institutional Framework for Corporate Financial Reporting, B.9 Auditing Standard-setting

    OpenAIRE

    World Bank

    2017-01-01

    The purpose of this report is to gain an understanding of the governance arrangements, procedures, and capacity for setting auditing standards in a jurisdiction, covering: (a) the adoption of International Standards on Auditing (ISA) where applicable, and (b) national auditing standards. The questions are based on examples of good practice followed by international standard-setting bodies....

  12. Transition of radiation protection standards in ICRP recommendations and Japan's response

    International Nuclear Information System (INIS)

    Shirabe, Masashi

    2016-01-01

    Radiation protection standards are the standards set for the purpose of preventing radiation hazard and other damage. This paper confirm what the International Commission on Radiological Protection (ICRP) recommended against the standard value on public exposure in Japan's laws and regulations, and how the Japanese government responded in introducing it into Japan's laws and regulations. There were delays of 6 to 12 years for the introduction of ICRP recommendations into the laws and regulations. Compared with response to the copyright treaty, which was extremely quick with the delays of only 1 to 2 years, these delays were very large. In Japan's laws and regulations, there are no regulations on the standard value for public exposure, and introduction of the recommended standard value of 1 mSv/year from ICRP has been avoided by the government. It is supposed that the reason for not introducing radiation dose limit and dose constraint value of public exposure was due to the lobbying of electric companies. After the Fukushima Daiichi nuclear accident, the former Nuclear Safety Commission set the reference level for emergency exposure situation at 20 mSv/year. Although there is the long-term target of 1 mSv/year for existing exposure, no reference level has been set yet. Due to these delays or avoidances, the rights of people suffering from radiation exposure are restricted, while perhaps the benefits of electric companies are being protected. (A.O.)

  13. Protein folding: Defining a standard set of experimental conditions and a preliminary kinetic data set of two-state proteins

    DEFF Research Database (Denmark)

    Maxwell, Karen L.; Wildes, D.; Zarrine-Afsar, A.

    2005-01-01

    Recent years have seen the publication of both empirical and theoretical relationships predicting the rates with which proteins fold. Our ability to test and refine these relationships has been limited, however, by a variety of difficulties associated with the comparison of folding and unfolding ...... efforts is to set uniform standards for the experimental community and to initiate an accumulating, self-consistent data set that will aid ongoing efforts to understand the folding process....... constructs. The lack of a single approach to data analysis and error estimation, or even of a common set of units and reporting standards, further hinders comparative studies of folding. In an effort to overcome these problems, we define here a consensus set of experimental conditions (25°C at pH 7.0, 50 m...... rates, thermodynamics, and structure across diverse sets of proteins. These difficulties include the wide, potentially confounding range of experimental conditions and methods employed to date and the difficulty of obtaining correct and complete sequence and structural details for the characterized...

  14. Patent challenges for standard-setting in the global economy : lessons from information and communication industry

    NARCIS (Netherlands)

    Maskus, K.; Merrill, S.A.; Bekkers, R.N.A.; Sandy Block, Marc; Contreras, Jorge; Gilbert, Richard; Goodman, David; Marasco, Amy; Simcoe, Tim; Smoot, Oliver; Suttmeier, Richard; Updegrove, Andrew

    2014-01-01

    Patent Challenges for Standard-Setting in the Global Economy: Lessons from Information and Communication Technology examines how leading national and multinational standard-setting organizations (SSOs) address patent disclosures, licensing terms, transfers of patent ownership, and other issues that

  15. Standard Setting as Psychometric Due Process: Going a Little Further Down an Uncertain Road.

    Science.gov (United States)

    Cizek, Gregory J.

    The concept of due process provides an analogy for the process of standard setting that emphasizes many of the procedural and substantive elements of the process over technical and statistical concerns. Surely such concerns can and should continue to be addressed. However, a sound rationale for standard setting does not rest on this foundation.…

  16. Implementing standard setting into the Conjoint MAFP/FRACGP Part 1 examination - Process and issues.

    Science.gov (United States)

    Chan, S C; Mohd Amin, S; Lee, T W

    2016-01-01

    The College of General Practitioners of Malaysia and the Royal Australian College of General Practitioners held the first Conjoint Member of the College of General Practitioners (MCGP)/Fellow of Royal Australian College of General Practitioners (FRACGP) examination in 1982, later renamed the Conjoint MAFP/FRACGP examinations. The examination assesses competency for safe independent general practice and as family medicine specialists in Malaysia. Therefore, a defensible standard set pass mark is imperative to separate the competent from the incompetent. This paper discusses the process and issues encountered in implementing standard setting to the Conjoint Part 1 examination. Critical to success in standard setting were judges' understanding of the process of the modified Angoff method, defining the borderline candidate's characteristics and the composition of judges. These were overcome by repeated hands-on training, provision of detailed guidelines and careful selection of judges. In December 2013, 16 judges successfully standard set the Part 1 Conjoint examinations, with high inter-rater reliability: Cronbach's alpha coefficient 0.926 (Applied Knowledge Test), 0.921 (Key Feature Problems).

  17. A Mapmark method of standard setting as implemented for the National Assessment Governing Board.

    Science.gov (United States)

    Schulz, E Matthew; Mitzel, Howard C

    2011-01-01

    This article describes a Mapmark standard setting procedure, developed under contract with the National Assessment Governing Board (NAGB). The procedure enhances the bookmark method with spatially representative item maps, holistic feedback, and an emphasis on independent judgment. A rationale for these enhancements, and the bookmark method, is presented, followed by a detailed description of the materials and procedures used in a meeting to set standards for the 2005 National Assessment of Educational Progress (NAEP) in Grade 12 mathematics. The use of difficulty-ordered content domains to provide holistic feedback is a particularly novel feature of the method. Process evaluation results comparing Mapmark to Anghoff-based methods previously used for NAEP standard setting are also presented.

  18. Factors Influencing the Degree of Intrajudge Consistency during the Standard Setting Process.

    Science.gov (United States)

    Plake, Barbara S.; And Others

    The accuracy of standards obtained from judgmental methods is dependent on the quality of the judgments made by experts throughout the standard setting process. One important dimension of the quality of these judgments is the consistency of the judges' perceptions with item performance of minimally competent candidates. Several interrelated…

  19. Evaluation of the Standard Setting on the 2005 Grade 12 National Assessment of Educational Progress Mathematics Test

    Science.gov (United States)

    Sireci, Stephen G.; Hauger, Jeffrey B.; Wells, Craig S.; Shea, Christine; Zenisky, April L.

    2009-01-01

    The National Assessment Governing Board used a new method to set achievement level standards on the 2005 Grade 12 NAEP Math test. In this article, we summarize our independent evaluation of the process used to set these standards. The evaluation data included observations of the standard-setting meeting, observations of advisory committee meetings…

  20. Variation in assessment and standard setting practices across UK undergraduate medicine and the need for a benchmark.

    Science.gov (United States)

    MacDougall, Margaret

    2015-10-31

    The principal aim of this study is to provide an account of variation in UK undergraduate medical assessment styles and corresponding standard setting approaches with a view to highlighting the importance of a UK national licensing exam in recognizing a common standard. Using a secure online survey system, response data were collected during the period 13 - 30 January 2014 from selected specialists in medical education assessment, who served as representatives for their respective medical schools. Assessment styles and corresponding choices of standard setting methods vary markedly across UK medical schools. While there is considerable consensus on the application of compensatory approaches, individual schools display their own nuances through use of hybrid assessment and standard setting styles, uptake of less popular standard setting techniques and divided views on norm referencing. The extent of variation in assessment and standard setting practices across UK medical schools validates the concern that there is a lack of evidence that UK medical students achieve a common standard on graduation. A national licensing exam is therefore a viable option for benchmarking the performance of all UK undergraduate medical students.

  1. A conceptual analysis of standard setting in large-scale assessments

    NARCIS (Netherlands)

    van der Linden, Willem J.

    1994-01-01

    Elements of arbitrariness in the standard setting process are explored, and an alternative to the use of cut scores is presented. The first part of the paper analyzes the use of cut scores in large-scale assessments, discussing three different functions: (1) cut scores define the qualifications used

  2. Integrated Data Collection Analysis (IDCA) Program — RDX Standard Data Sets

    Energy Technology Data Exchange (ETDEWEB)

    Sandstrom, Mary M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brown, Geoffrey W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Preston, Daniel N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pollard, Colin J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Warner, Kirstin F. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Sorensen, Daniel N. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Remmers, Daniel L. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Phillips, Jason J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Shelley, Timothy J. [Bureau of Alcohol, Tobacco and Firearms, Huntsville, AL (United States); Reyes, Jose A. [Applied Research Associates, Tyndall AFB, FL (United States); Hsu, Peter C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Reynolds, John G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-03-04

    The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of the RDX Type II Class 5 standard, for a third and fourth time in the Proficiency Test and averaged with the analysis results from the first and second time. The results, from averaging all four sets (1, 2, 3 and 4) of data suggest a material to have slightly more impact sensitivity, more BAM friction sensitivity, less ABL friction sensitivity, similar ESD sensitivity, and same DSC sensitivity, compared to the results from Set 1, which was used previously as the values for the RDX standard in IDCA Analysis Reports.

  3. Workplace standards for exposure to toxicants during pregnancy.

    Science.gov (United States)

    Till, Christine; Koren, Gideon; Rovet, Joanne F

    2008-01-01

    Many women of childbearing age are exposed to reproductive toxicants in the workplace. This article highlights the need for an evaluation of current occupational exposure guidelines for pregnant women working with hazardous agents that have the potential of being reproductive toxins. Limited information regarding reproductive risks associated with many chemicals in the workplace presents challenges in the establishment of standards that are 'safe' for vulnerable populations, such as the fetus. The management of these risks must take into consideration the limitations of available knowledge as well as individual risk factors that may amplify the likelihood of adverse outcomes. In 1981, Quebec adopted a policy that provides "precautionary leave" or reassignment of pregnant workers to other jobs if they are exposed to a factor suspected to compromise their health or that of their fetus during pregnancy. The advantages and disadvantages of this approach to managing reproductive hazards are discussed. The existence of a regulatory safety net at the level of the workplace for minimizing the impact of toxicant exposure on reproductive health outcomes is stressed. Management options that can be implemented early to provide added protection when a hazard cannot be reduced or eliminated are recommended.

  4. Estimating the Standard Error of the Judging in a modified-Angoff Standards Setting Procedure

    Directory of Open Access Journals (Sweden)

    Robert G. MacCann

    2004-03-01

    Full Text Available For a modified Angoff standards setting procedure, two methods of calculating the standard error of the..judging were compared. The Central Limit Theorem (CLT method is easy to calculate and uses readily..available data. It estimates the variance of mean cut scores as a function of the variance of cut scores within..a judging group, based on the independent judgements at Stage 1 of the process. Its theoretical drawback is..that it is unable to take account of the effects of collaboration among the judges at Stages 2 and 3. The..second method, an application of equipercentile (EQP equating, relies on the selection of very large stable..candidatures and the standardisation of the raw score distributions to remove effects associated with test..difficulty. The standard error estimates were then empirically obtained from the mean cut score variation..observed over a five year period. For practical purposes, the two methods gave reasonable agreement, with..the CLT method working well for the top band, the band that attracts most public attention. For some..bands in English and Mathematics, the CLT standard error was smaller than the EQP estimate, suggesting..the CLT method be used with caution as an approximate guide only.

  5. Association between Household Air Pollution Exposure and Chronic Obstructive Pulmonary Disease Outcomes in 13 Low- and Middle-Income Country Settings.

    Science.gov (United States)

    Siddharthan, Trishul; Grigsby, Matthew R; Goodman, Dina; Chowdhury, Muhammad; Rubinstein, Adolfo; Irazola, Vilma; Gutierrez, Laura; Miranda, J Jaime; Bernabe-Ortiz, Antonio; Alam, Dewan; Kirenga, Bruce; Jones, Rupert; van Gemert, Frederick; Wise, Robert A; Checkley, William

    2018-03-01

    Forty percent of households worldwide burn biomass fuels for energy, which may be the most important contributor to household air pollution. To examine the association between household air pollution exposure and chronic obstructive pulmonary disease (COPD) outcomes in 13 resource-poor settings. We analyzed data from 12,396 adult participants living in 13 resource-poor, population-based settings. Household air pollution exposure was defined as using biomass materials as the primary fuel source in the home. We used multivariable regressions to assess the relationship between household air pollution exposure and COPD outcomes, evaluated for interactions, and conducted sensitivity analyses to test the robustness of our findings. Average age was 54.9 years (44.2-59.6 yr across settings), 48.5% were women (38.3-54.5%), prevalence of household air pollution exposure was 38% (0.5-99.6%), and 8.8% (1.7-15.5%) had COPD. Participants with household air pollution exposure were 41% more likely to have COPD (adjusted odds ratio, 1.41; 95% confidence interval, 1.18-1.68) than those without the exposure, and 13.5% (6.4-20.6%) of COPD prevalence may be caused by household air pollution exposure, compared with 12.4% caused by cigarette smoking. The association between household air pollution exposure and COPD was stronger in women (1.70; 1.24-2.32) than in men (1.21; 0.92-1.58). Household air pollution exposure was associated with a higher prevalence of COPD, particularly among women, and it is likely a leading population-attributable risk factor for COPD in resource-poor settings.

  6. Standard Practice for Exposure of Cover Materials for Solar Collectors to Natural Weathering Under Conditions Simulating Operational Mode

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1995-01-01

    1.1 This practice provides a procedure for the exposure of cover materials for flat-plate solar collectors to the natural weather environment at temperatures that are elevated to approximate operating conditions. 1.2 This practice is suitable for exposure of both glass and plastic solar collector cover materials. Provisions are made for exposure of single and double cover assemblies to accommodate the need for exposure of both inner and outer solar collector cover materials. 1.3 This practice does not apply to cover materials for evacuated collectors or photovoltaics. 1.4 The values stated in SI units are to be regarded as the standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  7. A global historical data set of tropical cyclone exposure (TCE-DAT)

    Science.gov (United States)

    Geiger, Tobias; Frieler, Katja; Bresch, David N.

    2018-01-01

    Tropical cyclones pose a major risk to societies worldwide, with about 22 million directly affected people and damages of USD 29 billion on average per year over the last 20 years. While data on observed cyclones tracks (location of the center) and wind speeds are publicly available, these data sets do not contain information about the spatial extent of the storm and people or assets exposed. Here, we apply a simplified wind field model to estimate the areas exposed to wind speeds above 34, 64, and 96 knots (kn). Based on available spatially explicit data on population densities and gross domestic product (GDP) we estimate (1) the number of people and (2) the sum of assets exposed to wind speeds above these thresholds accounting for temporal changes in historical distribution of population and assets (TCE-hist) and assuming fixed 2015 patterns (TCE-2015). The associated spatially explicit and aggregated country-event-level exposure data (TCE-DAT) cover the period 1950 to 2015 and are freely available at https://doi.org/10.5880/pik.2017.011 (Geiger at al., 2017c). It is considered key information to (1) assess the contribution of climatological versus socioeconomic drivers of changes in exposure to tropical cyclones, (2) estimate changes in vulnerability from the difference in exposure and reported damages and calibrate associated damage functions, and (3) build improved exposure-based predictors to estimate higher-level societal impacts such as long-term effects on GDP, employment, or migration. We validate the adequateness of our methodology by comparing our exposure estimate to estimated exposure obtained from reported wind fields available since 1988 for the United States. We expect that the free availability of the underlying model and TCE-DAT will make research on tropical cyclone risks more accessible to non-experts and stakeholders.

  8. An International Standard Set of Patient-Centered Outcome Measures After Stroke

    NARCIS (Netherlands)

    Salinas, J. (Joel); Sprinkhuizen, S.M. (Sara M.); Ackerson, T. (Teri); Bernhardt, J. (Julie); Davie, C. (Charlie); George, M.G. (Mary G.); Gething, S. (Stephanie); Kelly, A.G. (Adam G.); Lindsay, P. (Patrice); Liu, L. (Liping); Martins, S.C.O. (Sheila C.O.); Morgan, L. (Louise); B. Norrving (Bo); Ribbers, G.M. (Gerard M.); Silver, F.L. (Frank L.); Smith, E.E. (Eric E.); Williams, L.S. (Linda S.); Schwamm, L.H. (Lee H.)

    2015-01-01

    markdownabstract__BACKGROUND AND PURPOSE:__ Value-based health care aims to bring together patients and health systems to maximize the ratio of quality over cost. To enable assessment of healthcare value in stroke management, an international standard set of patient-centered stroke outcome measures

  9. Radon exposure in uranium mining industry vs. exposure in tourist caves

    International Nuclear Information System (INIS)

    Quindos Poncela, L.; Fernandez Navarro, P.; Sainz Fernandez, C.; Gomez Arozamena, J.; Bordonoba Perez, M.

    2004-01-01

    There is a fairly general consensus among health physicists and radiation professionals that exposure to radon progeny is the largest and most variable contribution to the population's exposure to natural sources of radiation. However, this exposure is the subject of continuing debate concerning the validity of risk assessment and recommendations on how to act in radon-prone areas. The purpose of this contribution is to situate the radon issue in Spain in two very different settings. The first is a uranium mining industry located in Saelices el Chico (Salamanca), which is under strict control of the Spanish Nuclear Safety Council (CSN). We have measured radon concentrations in different workplaces in this mine over a five-year period. The second setting comprises four tourist caves, three of which are located in the province of Cantabria and the fourth on the Canary Island of Lanzarote. These caves are not subject to any administrative control of radiation exposure. Measured air 222 Rn concentrations were used to estimate annual effective doses due to radon inhalation in the two settings, and dose values were found to be from 2 to 10 times lower in the uranium mine than in the tourist caves. These results were analysed in the context of the new European Basic Safety Standards Directive (EU-BSS, 1996). (authors)

  10. The 1997 determination of the Australian standards of exposure and absorbed dose at {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Huntley, R.B.; Boas, J.F. [Australian Radiation Laboratory, Yallambie, VIC (Australia); Van der Gaast, H. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1998-05-01

    The arrangements for the maintenance of the Australian standards for {sup 60}Co are described in detail. The primary standards are a graphite cavity chamber for exposure/air kerma and a graphite calorimeter for absorbed dose. These secondary standards are described and their responses in corresponding {sup 90}Sr reference sources are reported. Accurate ratios between the Australian Radiation Laboratory (ARL) and Australian Nuclear Science and Technology (ANSTO) {sup 90}Sr reference sources are derived for use in future calibrations. The value of 28.8 years for the half-life of {sup 90}Sr is confirmed. The usefulness of {sup 90}Sr reference source measurements in quality assurance is discussed. The charge sensitivity and linearity of the ANSTO electrometers are reported by two different methods and are compared with previous results. Calibration factors for all the secondary standard ionization chambers are given, in terms of exposure, air kerma and absorbed dose to water. Calibration factors are also given for most of the chambers in terms of absorbed dose to graphite. The methods of deriving the calibration factors are explained in detail, including all the corrections applied to both the primary and secondary standard measurements. Three alternative methods of deriving the absorbed dose to water calibration factors are compared. The reported calibration factors are compared with previous results. Changes in the Australian units of exposure, air kerma and absorbed dose to graphite and water are derived from changes in the corresponding calibration factors. The Australian units of exposure and air kerma have not changed significantly since 1990. The Australian unit of absorbed dose to graphite is now 1.1 % smaller than in 1993 and 1.3 % smaller than in 1990. The Australian unit of absorbed dose to water is now 1.4 % smaller than in 1993, but is only 0.9 % smaller than in 1990. Comparisons of the Australian standards of exposure/air kerma and absorbed dose with

  11. Improved inhalation technology for setting safe exposure levels for workplace chemicals

    Science.gov (United States)

    Stuart, Bruce O.

    1993-01-01

    Threshold Limit Values recommended as allowable air concentrations of a chemical in the workplace are often based upon a no-observable-effect-level (NOEL) determined by experimental inhalation studies using rodents. A 'safe level' for human exposure must then be estimated by the use of generalized safety factors in attempts to extrapolate from experimental rodents to man. The recent development of chemical-specific physiologically-based toxicokinetics makes use of measured physiological, biochemical, and metabolic parameters to construct a validated model that is able to 'scale-up' rodent response data to predict the behavior of the chemical in man. This procedure is made possible by recent advances in personal computer software and the emergence of appropriate biological data, and provides an analytical tool for much more reliable risk evaluation and airborne chemical exposure level setting for humans.

  12. Biological bases of the maximum permissible exposure levels of the UK laser standard BS 4803: 1983

    International Nuclear Information System (INIS)

    McKinlay, A.F.; Harlen, F.

    1983-10-01

    The use of lasers has increased greatly over the past 15 years or so, to the extent that they are now used routinely in many occupational and public situations. There has been an increasing awareness of the potential hazards presented by lasers and substantial efforts have been made to formulate safety standards. In the UK the relevant Safety Standard is the British Standards Institution Standard BS 4803. This Standard was originally published in 1972 and a revision has recently been published (BS 4803: 1983). The revised standard has been developed using the American National Standards Institute Standard, ANSI Z136.1 (1973 onwards), as a model. In other countries, national standards have been similarly formulated, resulting in a large measure of international agreement through participation in the work of the International Electrotechnical Commission (IEC). The bases of laser safety standards are biophysical data on threshold injury effects, particularly on the retina, and the development of theoretical models of damage mechanisms. This report deals in some detail with the mechanisms of injury from over exposure to optical radiations, in particular with the dependency of the type and degree of damage on wavelength, image size and pulse duration. The maximum permissible exposure levels recommended in BS 4803: 1983 are compared with published data for damage thresholds and the adequacy of the standard is discussed. (author)

  13. Secondary electron images obtained with a standard PEEM set up

    International Nuclear Information System (INIS)

    Benka, O.; Zeppenfeld, P.

    2004-01-01

    Secondary electron images excited by 3 to 4.3 keV electrons are obtained with a standard photoelectron electron emission microscope (PEEM) set up equipped with an imaging energy filter (IEF). The electron gun was mounted on a standard PEEM entrance flange at an angle of 25 o with respect to the sample surface. A low extraction voltage of 500 V was used to minimize the deflection of the electron beam by the PEEM extraction electrode. The secondary electron images are compared to photoelectron images excited by a standard 4.9 eV UV lamp. In the case of a Cu pattern on a Si substrate it is found that the lateral resolution without the IEF is about the same for electron and photon excitation but that the relative electron emission intensities are very different. The use of the IEF-reduces the lateral resolution. Images for secondary electron energies between eV 1 and eV 2 were obtained by setting the IEF to -V 1 and -V 2 ∼ -(V 1 + 5V) potentials and taking the difference of both images. Images up to 100 eV electron energies were recorded. The lateral resolution is in the range of μm. The material contrast obtained in these difference images are discussed in terms of a secondary electron and photoelectron emission model and secondary electron energy spectra measured with a LEED-Auger spectrometer. (author)

  14. A comparison of important international and national standards for limiting exposure to EMF including the scientific rationale.

    Science.gov (United States)

    Roy, Colin R; Martin, Lindsay J

    2007-06-01

    A comparison of Eastern (from Russia, Hungary, Bulgaria, Poland, and the Czech Republic) and Western (represented by the International Commission on Non-Ionizing Radiation Protection guidelines and the Institute of Electrical and Electronic Engineers standards) radiofrequency standards reveals key differences. The Eastern approach is to protect against non-thermal effects caused by chronic exposure to low level exposure, and the occupational basic restriction is power load (the product of intensity and exposure duration). In contrast, the Western approach is to protect against established acute biological effects that could signal an adverse health effect, and the principal basic restriction is the specific absorption rate to protect against thermal effects. All of the standards are science-based, but a fundamental difference arises from a lack of agreement on the composition of the reference scientific database and of which adverse effect needs to be protected against. However, differences also exist between the ICNIRP and IEEE standards. An additional complication arises when standards are derived or modified using a precautionary approach. For ELF the differences between ICNIRP and IEEE are more fundamental; namely, differences in the basic restriction used (induced current; in-situ electric field) and the location of breakpoints in the strength-frequency curves result in large differences. In 2006, ICNIRP will initiate the review of their ELF and radiofrequency guidelines, and this will provide an opportunity to address differences in standards and the move towards harmonization of EMF standards and guidelines.

  15. Food marketing to children in Canada: a settings-based scoping review on exposure, power and impact.

    Science.gov (United States)

    Prowse, Rachel

    2017-09-01

    Food marketing impacts children's food knowledge, behaviours and health. Current regulations in Canada focus on restricting promotional aspects of food marketing with little-to-no consideration of the places where children experience food. Understanding food marketing in children's everyday settings is necessary to protect children. This scoping review describes the current literature on food marketing to children in Canada by setting. The author searched databases for Canadian research on children's exposure to food marketing, and the power and impact of food marketing to children (2-17 years) across settings, and on how current regulations may mediate the effect of food marketing on children. Peer-reviewed studies in English, published between 2000 and 2016, were included. Twenty-five studies documented children's exposure to food marketing and its power and/or impact on them in homes (via television, or online) (n = 12), public schools (n = 1), grocery stores (n = 8), fast food restaurants (n = 2), and in general (n = 2). Research trends suggest that unhealthy foods are targeted at children using multiple promotional techniques that overlap across settings. Several research gaps exist in this area, leading to an incomplete, and potentially underestimated, picture of food marketing to children in Canada. Available evidence suggests that current Canadian approaches have not reduced children's exposure to or the power of food marketing in these settings, with the exception of some positive influences from Quebec's statutory regulations. The settings where children eat, buy or learn about food expose them to powerful, often unhealthy food marketing. The current evidence suggests that "place" may be an important marketing component to be included in public policy in order to broadly protect children from unhealthy food marketing. Organizations and communities can engage in settings-based health promotion interventions by developing their own marketing policies that

  16. Exposure to environmental tobacco smoke (ETS) and determinants of support for complete smoking bans in psychiatric settings.

    NARCIS (Netherlands)

    Willemsen, M.C.; Gorts, C.A.; Soelen, P. van; Jonkers, R.E.; Hilberink, S.R.

    2004-01-01

    OBJECTIVE: To measure environmental tobacco smoke (ETS) exposure in psychiatric settings and to assess determinants of support for complete smoking bans. DESIGN: Cross sectional study SETTING: Dutch psychiatric hospitals, outpatient care institutions, and sheltered home facilities. SUBJECTS: A

  17. How Good Is Good Enough? Educational Standard Setting and Its Effect on African American Test Takers

    Science.gov (United States)

    Caines, Jade; Engelhard, George, Jr.

    2012-01-01

    Standard setting (the process of establishing minimum passing scores on high-stakes exams) is a highly evaluative and policy-driven process. It is a common belief that standard setting panels should be diverse and representative. There is concern, however, that panelists with varying characteristics may differentially influence the results of the…

  18. PERBANDINGAN ESTIMASI KESALAHAN PENGUKURAN STANDARD SETTING DALAM PENILAIAN KOMPETENSI AKUNTANSI SMK

    Directory of Open Access Journals (Sweden)

    Sebastianus Widanarto Prijowuntato

    2015-10-01

      ESTIMATION OF STANDARD SETTING ERROR MEASUREMENT IN ACCOUNTING COMPETENCY ASSESSMENT IN VOCATIONAL SCHOOLS Abstract This research aims to estimate the measurement error in the Angof, Ebel, and Bookmark methods in Accounting Competency Assessment in Vocational Schools in DIY used by standard setters in deciding a cut score. This research is quantitative research. Data source in this study was the cut score of seven vocational schools in Yogyakarta that were randomly established. The reseach data were students’ answers to the National Examination in Accounting Subject of Package 2 in the academic year of 2011/2012 with 338 students. The teachers who engaged in the Focus Group Discussion (FGD were nine teachers, consisting of seven women and two men. The technical analysis was divided into three stages. 1 preparation, 2 FGD, 3 estimated error measurement by using the Bootstrap method. The results show that the cut score for the Angoff method is 67.809, Ebel method is 59.034, and Bookmark method is 57.022. The Angoff method has the least estimation of the measurement errors (2.102 as compared with the Ebel method (4.004 and the Bookmark method (4.042. Therefore, the Angoff method is the right method for estimating error measurement on standard setting. Keywords: Estimation of error measurement, Bootstrap, Cut Score

  19. Integrated Data Collection Analysis (IDCA) Program - RDX Standard Data Set 2

    Energy Technology Data Exchange (ETDEWEB)

    Sandstrom, Mary M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brown, Geoffrey W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Preston, Daniel N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pollard, Colin J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Warner, Kirstin F. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Sorensen, Daniel N. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Remmers, Daniel L. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Phillips, Jason J. [Air Force Research Lab. (AFRL), Tyndall Air Force Base, FL (United States); Shelley, Timothy J. [Applied Research Associates, Tyndall Air Force Base, FL (United States); Reyes, Jose A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hsu, Peter C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Reynolds, John G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-02-20

    The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of the RDX Type II Class 5 standard, from testing the second time in the Proficiency Test. This RDX testing (Set 2) compared to the first (Set 1) was found to have about the same impact sensitivity, have more BAM friction sensitivity, less ABL friction sensitivity, similar ESD sensitivity, and same DSC sensitivity.

  20. Fluoroscopic radiation exposure: are we protecting ourselves adequately?

    Science.gov (United States)

    Hoffler, C Edward; Ilyas, Asif M

    2015-05-06

    While traditional intraoperative fluoroscopy protection relies on thyroid shields and aprons, recent data suggest that the surgeon's eyes and hands receive more exposure than previously appreciated. Using a distal radial fracture surgery model, we examined (1) radiation exposure to the eyes, thyroid, chest, groin, and hands of a surgeon mannequin; (2) the degree to which shielding equipment can decrease exposure; and (3) how exposure varies with fluoroscopy unit size. An anthropomorphic model was fit with radiation-attenuating glasses, a thyroid shield, an apron, and gloves. "Exposed" thermoluminescent dosimeters overlaid the protective equipment at the eyes, thyroid, chest, groin, and index finger while "shielded" dosimeters were placed beneath the protective equipment. Fluoroscopy position and settings were standardized. The mini-c-arm milliampere-seconds were fixed based on the selection of the kilovolt peak (kVp). Three mini and three standard c-arms scanned a model of the patient's wrist continuously for fifteen minutes each. Ten dosimeter exposures were recorded for each c-arm. Hand exposure averaged 31 μSv/min (range, 22 to 48 μSv/min), which was 13.0 times higher than the other recorded exposures. Eye exposure averaged 4 μSv/min, 2.2 times higher than the mean thyroid, chest, and groin exposure. Gloves reduced hand exposure by 69.4%. Glasses decreased eye exposure by 65.6%. There was no significant difference in exposure between mini and standard fluoroscopy. Surgeons' hands receive the most radiation exposure during distal radial plate fixation under fluoroscopy. There was a small but insignificant difference in mean exposure between standard fluoroscopy and mini-fluoroscopy, but some standard units resulted in lower exposure than some mini-units. On the basis of these findings, we recommend routine protective equipment to mitigate exposure to surgeons' hands and eyes, in addition to the thyroid, chest, and groin, during fluoroscopy procedures

  1. Innovations in Setting Performance Standards for K-12 Test-Based Accountability

    Science.gov (United States)

    Huff, Kristen; Plake, Barbara S.

    2010-01-01

    Standard setting is a systematic process that uses a combination of judgmental and empirical procedures to make recommendations about where on the score continuum "cut scores" should be placed. Cut scores divide the score scale into categories consistent with the descriptions of student performance associated with multiple levels of achievement.…

  2. UK standards for exposure to radon daughters in dwellings

    International Nuclear Information System (INIS)

    Webb, G.A.M.; O'Riordan, M.C.

    1988-01-01

    The National Radiological Protection Board has issued formal advice on the standards to be adopted in the UK for control of exposures to radon daughters in existing dwellings and for changes in building procedures for future dwellings. The standards are based on those recommended by the International Commission on Radiological Protection but adapted to circumstances in the United Kingdom. The matters taken into account by the Board when formulating its advice include the conversion from measured concentrations of radon to effective dose equivalent and the implied levels of risk, the comparison of these levels with risks from other causes, the numbers of dwellings in which various annual doses are likely to be exceeded, the geographical distribution of these dwellings, the likely costs and effectiveness of various remedial measures and the degree of domestic disruption. The action level for existing dwellings selected by the Board was the same, 20 mSv per annum, as that recommended by the ICRP, but the upper bound for new dwellings of 5 mSv per annum was lower than that suggested by the ICRP

  3. Regional radiation standards for population of Chelyabinsk region

    International Nuclear Information System (INIS)

    Kravtsova, Eh.M.; Zajtseva, Yh.A.; Panteleev, V.V.; Gavrilov, A.P.; Kolotygina, N.V.; Pudovkina, L.V.; Kravtsova, O.S.

    1996-01-01

    Regional radiation regulations for population exposures in Chelyabinsk region are developed which are to play the role of standard limits. The priority goal of setting standard level is to consolidate the achieved radioecological balance on the contaminated territories and to establish a mechanism of control over the activities of the facility and over the use of lands in restriction zone by the population

  4. An analysis of violations of Osha's (1987) occupational exposure to benzene standard.

    Science.gov (United States)

    Williams, Pamela R D

    2014-01-01

    The Occupational Safety and Health Administration (OSHA), which was formed by the Occupational Safety and Health Act of 1970 (OSH Act), establishes enforceable health and safety standards in the workplace and issues violations and penalties for non-compliance with these standards. The purpose of the current study was to evaluate the number and type of violations of the OSHA (1987) Occupational Exposure to Benzene Standard. Violations of the OSHA Hazard Communication Standard (HCS), particularly those that may pertain to specific provisions of the benzene standard, were also assessed. All analyses were based on OSHA inspection data that have been collected since the early 1970s and that are publicly available from the U.S. Department of Labor enforcement website. Analysis of these data shows that fewer than a thousand OSHA violations of the benzene standard have been issued over the last 25+ years. The results for benzene are in contrast to those for some other toxic and hazardous substances that are regulated by OSHA, such as blood-borne pathogens, lead, and asbestos, for which there have been issued tens of thousands of OSHA violations. The number of benzene standard violations also varies by time period, standard provision, industry sector, and other factors. In particular, the greatest number of benzene standard violations occurred during the late 1980s to early/mid 1990s, soon after the 1987 final benzene rule was promulgated. The majority of benzene standard violations also pertain to noncompliance with specific provisions and subprovisions of the standard dealing with initial exposure monitoring requirements, the communication of hazards to employees, and medical surveillance programs. Only a small fraction of HCS violations are attributed, at least in part, to potential benzene hazards in the workplace. In addition, most benzene standard violations are associated with specific industries within the manufacturing sector where benzene or benzene

  5. Comparing Panelists' Understanding of Standard Setting across Multiple Levels of an Alternate Science Assessment

    Science.gov (United States)

    Hansen, Mary A.; Lyon, Steven R.; Heh, Peter; Zigmond, Naomi

    2013-01-01

    Large-scale assessment programs, including alternate assessments based on alternate achievement standards (AA-AAS), must provide evidence of technical quality and validity. This study provides information about the technical quality of one AA-AAS by evaluating the standard setting for the science component. The assessment was designed to have…

  6. Food marketing to children in Canada: a settings-based scoping review on exposure, power and impact

    Science.gov (United States)

    Rachel, Prowse

    2017-01-01

    Abstract Introduction: Food marketing impacts children’s food knowledge, behaviours and health. Current regulations in Canada focus on restricting promotional aspects of food marketing with little-to-no consideration of the places where children experience food. Understanding food marketing in children’s everyday settings is necessary to protect children. This scoping review describes the current literature on food marketing to children in Canada by setting. Methods: The author searched databases for Canadian research on children’s exposure to food marketing, and the power and impact of food marketing to children (2-17 years) across settings, and on how current regulations may mediate the effect of food marketing on children. Peer-reviewed studies in English, published between 2000 and 2016, were included. Results: Twenty-five studies documented children’s exposure to food marketing and its power and/or impact on them in homes (via television, or online) (n = 12), public schools (n = 1), grocery stores (n = 8), fast food restaurants (n = 2), and in general (n = 2). Research trends suggest that unhealthy foods are targeted at children using multiple promotional techniques that overlap across settings. Several research gaps exist in this area, leading to an incomplete, and potentially underestimated, picture of food marketing to children in Canada. Available evidence suggests that current Canadian approaches have not reduced children’s exposure to or the power of food marketing in these settings, with the exception of some positive influences from Quebec’s statutory regulations. Conclusion: The settings where children eat, buy or learn about food expose them to powerful, often unhealthy food marketing. The current evidence suggests that “place” may be an important marketing component to be included in public policy in order to broadly protect children from unhealthy food marketing. Organizations and communities can engage in settings-based health

  7. Food marketing to children in Canada: a settings-based scoping review on exposure, power and impact

    Directory of Open Access Journals (Sweden)

    Rachel Prowse

    2017-09-01

    Full Text Available Introduction: Food marketing impacts children’s food knowledge, behaviours and health. Current regulations in Canada focus on restricting promotional aspects of food marketing with little-to-no consideration of the places where children experience food. Understanding food marketing in children’s everyday settings is necessary to protect children. This scoping review describes the current literature on food marketing to children in Canada by setting. Methods: The author searched databases for Canadian research on children’s exposure to food marketing, and the power and impact of food marketing to children (2-17 years across settings, and on how current regulations may mediate the effect of food marketing on children. Peer-reviewed studies in English, published between 2000 and 2016, were included. Results: Twenty-five studies documented children’s exposure to food marketing and its power and/or impact on them in homes (via television, or online (n = 12, public schools (n = 1, grocery stores (n = 8, fast food restaurants (n = 2, and in general (n = 2. Research trends suggest that unhealthy foods are targeted at children using multiple promotional techniques that overlap across settings. Several research gaps exist in this area, leading to an incomplete, and potentially underestimated, picture of food marketing to children in Canada. Available evidence suggests that current Canadian approaches have not reduced children’s exposure to or the power of food marketing in these settings, with the exception of some positive influences from Quebec’s statutory regulations. Conclusion: The settings where children eat, buy or learn about food expose them to powerful, often unhealthy food marketing. The current evidence suggests that “place” may be an important marketing component to be included in public policy in order to broadly protect children from unhealthy food marketing. Organizations and communities can engage in settings-based health

  8. Occupational exposures worldwide and revision of international standards for protection

    International Nuclear Information System (INIS)

    Czarwinski, R.; Crick, M. J.

    2011-01-01

    United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) has become the world authority on the levels and effects of ionising radiation. Since 1975, UNSCEAR has evaluated inter alia the level of occupational exposure worldwide. Based on revised questionnaires, more detailed information is now available. The results of the last evaluation (1995-2002) will be shown in the paper. Lessons learned from the responses by UN Member States will be given, as well as an outline of plans for data collection in future cycles. The requirements for protection against exposure to ionising radiation of workers, the public and patients are established in the International Basic Safety Standards for Protection against Ionising Radiation and for the Safety of Radiation Sources (BSS), published in 1996. As a result of a review of the BSS in 2006, the International Atomic Energy Agency (IAEA) started a process for the revision of these standards in 2007. International organisations including the joint sponsoring organisations of the BSS-IAEA, FAO, ILO, OECD/NEA, PAHO and WHO-as well as potential new joint sponsoring organisations of the revised BSS-the European Commission and UNEP-were involved from the beginning in the revision process. The paper also provides a summary of the status of the Draft Revised BSS and describes the new format. The paper focuses, in particular, on requirements for the protection of workers as well as record keeping requirements, which provide the legal basis for the collection of specific data; these data are of the type that can be used by UNSCEAR. (authors)

  9. Occupational exposure of NRM spectrometrists to static and radiofrequency fields

    International Nuclear Information System (INIS)

    Berlana, Tania; Ubeda, Alejandro

    2017-01-01

    Occupational exposure to static and radiofrequency fields emitted by nuclear magnetic resonance spectrometers was assessed through systematic field metering during operation of 19 devices in nine research centers. Whereas no measurable levels of radiofrequency radiation were registered outside the spectrometers, significant exposure to static field was detected, with maximum values recorded at the user s hand (B = 683.00 mT) and head thorax (B = 135.70 mT) during spectrometer manipulation. All values were well below the exposure limits set by the European standard for workers protection against the effects of acute field exposure only. As for potential effects of chronic exposure, waiting for more complete knowledge, adoption of technical and operational strategies for exposure minimizing is advisable. In this respect, the data revealed that compared with standard magnetic shielding, ultra-shield technology allows a 20-65-fold reduction of the field strength received by the operator. (authors)

  10. Standard Practice for Exposure of Solar Collector Cover Materials to Natural Weathering Under Conditions Simulating Stagnation Mode

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1992-01-01

    1.1 This practice covers a procedure for the exposure of solar collector cover materials to the natural weather environment at elevated temperatures that approximate stagnation conditions in solar collectors having a combined back and edge loss coefficient of less than 1.5 W/(m2 · °C). 1.2 This practice is suitable for exposure of both glass and plastic solar collector cover materials. Provisions are made for exposure of single and double cover assemblies to accommodate the need for exposure of both inner and outer solar collector cover materials. 1.3 This practice does not apply to cover materials for evacuated collectors, photovoltaic cells, flat-plate collectors having a combined back and edge loss coefficient greater than 1.5 W/(m2 ·° C), or flat-plate collectors whose design incorporates means for limiting temperatures during stagnation. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard t...

  11. UK standards for exposure to radon daughters in dwellings

    International Nuclear Information System (INIS)

    Webb, G.A.M.; O'Riordan, M.C.

    1988-01-01

    The National Radiological Protection Board has issued formal advice on the standards to be adopted in the UK for control of exposures to radon daughters in existing dwellings and for changes in building procedures for future dwellings. The standards are based on those recommended by the international commission on radiological protection but adapted to circumstances in the United Kingdom. The matters taken into account by the Board when formulating its advice, and which are discussed in the paper, include the conversion from measured concentrations of radon to effective dose equivalent and the implied levels of risk, the comparison of these levels with risks from other causes, the numbers of dwellings in which various annual doses are likely to be exceeded, the geographical distribution of these dwellings, the likely costs and effectiveness of various remedial measures and the degree of domestic disruption. The action level for existing dwellings selected by the Board was the same, 20 mSv per annum, as that recommended by the ICRP, but the upper bound for new dwellings of 5 mSv per annum was lower than that suggested by the ICRP [fr

  12. A standardized non-instrumental tool for characterizing workstations concerned with exposure to engineered nanomaterials

    Science.gov (United States)

    Canu I, Guseva; C, Ducros; S, Ducamp; L, Delabre; S, Audignon-Durand; C, Durand; Y, Iwatsubo; D, Jezewski-Serra; Bihan O, Le; S, Malard; A, Radauceanu; M, Reynier; M, Ricaud; O, Witschger

    2015-05-01

    The French national epidemiological surveillance program EpiNano aims at surveying mid- and long-term health effects possibly related with occupational exposure to either carbon nanotubes or titanium dioxide nanoparticles (TiO2). EpiNano is limited to workers potentially exposed to these nanomaterials including their aggregates and agglomerates. In order to identify those workers during the in-field industrial hygiene visits, a standardized non-instrumental method is necessary especially for epidemiologists and occupational physicians unfamiliar with nanoparticle and nanomaterial exposure metrology. A working group, Quintet ExpoNano, including national experts in nanomaterial metrology and occupational hygiene reviewed available methods, resources and their practice in order to develop a standardized tool for conducting company industrial hygiene visits and collecting necessary information. This tool, entitled “Onsite technical logbook”, includes 3 parts: company, workplace, and workstation allowing a detailed description of each task, process and exposure surrounding conditions. This logbook is intended to be completed during the company industrial hygiene visit. Each visit is conducted jointly by an industrial hygienist and an epidemiologist of the program and lasts one or two days depending on the company size. When all collected information is computerized using friendly-using software, it is possible to classify workstations with respect to their potential direct and/or indirect exposure. Workers appointed to workstations classified as concerned with exposure are considered as eligible for EpiNano program and invited to participate. Since January 2014, the Onsite technical logbook has been used in ten company visits. The companies visited were mostly involved in research and development. A total of 53 workstations with potential exposure to nanomaterials were pre-selected and observed: 5 with TiO2, 16 with single-walled carbon nanotubes, 27 multiwalled

  13. A standardized non-instrumental tool for characterizing workstations concerned with exposure to engineered nanomaterials

    International Nuclear Information System (INIS)

    I, Guseva Canu; S, Ducamp; L, Delabre; Y, Iwatsubo; D, Jezewski-Serra; C, Ducros; S, Audignon-Durand; C, Durand; O, Le Bihan; S, Malard; A, Radauceanu; M, Reynier; M, Ricaud; O, Witschger

    2015-01-01

    The French national epidemiological surveillance program EpiNano aims at surveying mid- and long-term health effects possibly related with occupational exposure to either carbon nanotubes or titanium dioxide nanoparticles (TiO 2 ). EpiNano is limited to workers potentially exposed to these nanomaterials including their aggregates and agglomerates. In order to identify those workers during the in-field industrial hygiene visits, a standardized non-instrumental method is necessary especially for epidemiologists and occupational physicians unfamiliar with nanoparticle and nanomaterial exposure metrology. A working group, Quintet ExpoNano, including national experts in nanomaterial metrology and occupational hygiene reviewed available methods, resources and their practice in order to develop a standardized tool for conducting company industrial hygiene visits and collecting necessary information. This tool, entitled “Onsite technical logbook”, includes 3 parts: company, workplace, and workstation allowing a detailed description of each task, process and exposure surrounding conditions. This logbook is intended to be completed during the company industrial hygiene visit. Each visit is conducted jointly by an industrial hygienist and an epidemiologist of the program and lasts one or two days depending on the company size. When all collected information is computerized using friendly-using software, it is possible to classify workstations with respect to their potential direct and/or indirect exposure. Workers appointed to workstations classified as concerned with exposure are considered as eligible for EpiNano program and invited to participate. Since January 2014, the Onsite technical logbook has been used in ten company visits. The companies visited were mostly involved in research and development. A total of 53 workstations with potential exposure to nanomaterials were pre-selected and observed: 5 with TiO 2 , 16 with single-walled carbon nanotubes, 27 multiwalled

  14. Standard guidelines for setting up a dermatosurgery theatre

    Directory of Open Access Journals (Sweden)

    Rajendran S

    2009-08-01

    Full Text Available Introduction, definition, rationale and scope: Dermatologists in India are now increasingly performing surgical and cosmetic procedures in their practice. This calls for minimum standards at the national level with the main focus of patient safety and hence the guidelines for setting up a dermatosurgical theatre. Facility: The dermatosurgery theatre can be created in either physician′s clinic, or a hospital depending on the procedure to be performed. The dermatosurgery theatre requires careful planning with regards to - location, dimension, shell design, lighting, electrical requirements, operation table, chair, trolley, surgical instruments, sterilization of devices, asepsis and advanced life support. Apart from physical considerations, other considerations including theatre etiquettes, consent for surgery, safety of dermatosurgeon, theatre staff and lastly biomedical waste management should be looked into. These issues are discussed in detail in the recommendations.

  15. The primary exposure standard of ENEA for medium energy X-ray: characteristics and measurements procedures

    International Nuclear Information System (INIS)

    Laitano, R.F.; Toni, M.P.

    1983-01-01

    A description is given of a medium energy X-ray free-air chamber used, as primary exposure standard, at the Laboratorio di Metrologia delle Radiazioni Ionizzanti of the Enea in Italy. The main features of an X-ray facility for the production of radiation between 40 KeV and 400 KeV are also described. The measurements procedures are then analyzed with respect to the realization of the exposure unit in the relevant energy range. Finally the results of some international comparisons are reported

  16. [Prediction of the total Japanese cedar pollen counts based on male flower-setting conditions of standard trees].

    Science.gov (United States)

    Yuta, Atsushi; Ukai, Kotaro; Sakakura, Yasuo; Tani, Hideshi; Matsuda, Fukiko; Yang, Tian-qun; Majima, Yuichi

    2002-07-01

    We made a prediction of the Japanese cedar (Cryptomeria japonica) pollen counts at Tsu city based on male flower-setting conditions of standard trees. The 69 standard trees from 23 kinds of clones, planted at Mie Prefecture Science and Technology Promotion Center (Hakusan, Mie) in 1964, were selected. Male flower-setting conditions for 276 faces (69 trees x 4 points of the compass) were scored from 0 to 3. The average of scores and total pollen counts from 1988 to 2000 was analyzed. As the results, the average scores from standard trees and total pollen counts except two mass pollen-scattered years in 1995 and 2000 had a positive correlation (r = 0.914) by linear function. On the mass pollen-scattered years, pollen counts were influenced from the previous year. Therefore, the score of the present year minus that of the previous year were used for analysis. The average scores from male flower-setting conditions and pollen counts had a strong positive correlation (r = 0.994) when positive scores by taking account of the previous year were analyzed. We conclude that prediction of pollen counts are possible based on the male flower-setting conditions of standard trees.

  17. 75 FR 62686 - Health Information Technology: Revisions to Initial Set of Standards, Implementation...

    Science.gov (United States)

    2010-10-13

    ... Health Information Technology: Revisions to Initial Set of Standards, Implementation Specifications, and... Health Information Technology (ONC), Department of Health and Human Services. ACTION: Interim final rule... Coordinator for Health Information Technology, Attention: Steven Posnack, Hubert H. Humphrey Building, Suite...

  18. An Investigation of Undefined Cut Scores with the Hofstee Standard-Setting Method

    Science.gov (United States)

    Wyse, Adam E.; Babcock, Ben

    2017-01-01

    This article provides an overview of the Hofstee standard-setting method and illustrates several situations where the Hofstee method will produce undefined cut scores. The situations where the cut scores will be undefined involve cases where the line segment derived from the Hofstee ratings does not intersect the score distribution curve based on…

  19. Development and evaluation of probability density functions for a set of human exposure factors

    Energy Technology Data Exchange (ETDEWEB)

    Maddalena, R.L.; McKone, T.E.; Bodnar, A.; Jacobson, J.

    1999-06-01

    The purpose of this report is to describe efforts carried out during 1998 and 1999 at the Lawrence Berkeley National Laboratory to assist the U.S. EPA in developing and ranking the robustness of a set of default probability distributions for exposure assessment factors. Among the current needs of the exposure-assessment community is the need to provide data for linking exposure, dose, and health information in ways that improve environmental surveillance, improve predictive models, and enhance risk assessment and risk management (NAS, 1994). The U.S. Environmental Protection Agency (EPA) Office of Emergency and Remedial Response (OERR) plays a lead role in developing national guidance and planning future activities that support the EPA Superfund Program. OERR is in the process of updating its 1989 Risk Assessment Guidance for Superfund (RAGS) as part of the EPA Superfund reform activities. Volume III of RAGS, when completed in 1999 will provide guidance for conducting probabilistic risk assessments. This revised document will contain technical information including probability density functions (PDFs) and methods used to develop and evaluate these PDFs. The PDFs provided in this EPA document are limited to those relating to exposure factors.

  20. Development and evaluation of probability density functions for a set of human exposure factors

    International Nuclear Information System (INIS)

    Maddalena, R.L.; McKone, T.E.; Bodnar, A.; Jacobson, J.

    1999-01-01

    The purpose of this report is to describe efforts carried out during 1998 and 1999 at the Lawrence Berkeley National Laboratory to assist the U.S. EPA in developing and ranking the robustness of a set of default probability distributions for exposure assessment factors. Among the current needs of the exposure-assessment community is the need to provide data for linking exposure, dose, and health information in ways that improve environmental surveillance, improve predictive models, and enhance risk assessment and risk management (NAS, 1994). The U.S. Environmental Protection Agency (EPA) Office of Emergency and Remedial Response (OERR) plays a lead role in developing national guidance and planning future activities that support the EPA Superfund Program. OERR is in the process of updating its 1989 Risk Assessment Guidance for Superfund (RAGS) as part of the EPA Superfund reform activities. Volume III of RAGS, when completed in 1999 will provide guidance for conducting probabilistic risk assessments. This revised document will contain technical information including probability density functions (PDFs) and methods used to develop and evaluate these PDFs. The PDFs provided in this EPA document are limited to those relating to exposure factors

  1. Influence of exposure time on toxicity-An overview.

    Science.gov (United States)

    Connell, Des W; Yu, Qiming J; Verma, Vibha

    2016-04-29

    Data on toxicity of chemicals is usually reported as the LD50, or LC50, with the exposure time from experimental testing in the laboratory reported. But the exposure time is not considered to be a quantifiable variable which can be used to evaluate its importance in expressed toxicity, often described in general terms such as acute, chronic and so on. For the last hundred years Habers Rule has been successfully used to extrapolate from reported exposure times to other exposure times which may be needed for setting standards, health risk assessments and other applications. But it has limitations particularly in environmental applications where exposure levels are low and exposure times are relatively long. The Reduced Life Expectancy (RLE) model overcomes these problems and can be utilised under all exposure conditions. It can be expressed as ln(LT50)=-a (LC50)(ν)+b where the constants ν, a and b can be evaluated by fitting the model to experimental data on the LC50, and corresponding LT50, together with the Normal Life Expectancy (NLE) of the organism being considered as a data point when the LC50 is zero. The constant, ν, at a value of unity gives a linear relationship and where νmodel for fish, invertebrates and mammals involving 115 data sets and with a wide range of organic and inorganic toxicants the RLE model gave correlation coefficients of >0.8 with 107 sets of data. The RLE model can be used to extrapolate from a limited data set on exposure times and corresponding LT50 values to any exposure time and corresponding LT50 value. The discrepancy between Haber's Rule and RLE model increases as the exposure time increases. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  2. Secondary electron images obtained with a standard photoelectron emission microscope set-up

    International Nuclear Information System (INIS)

    Benka, Oswald; Zeppenfeld, Peter

    2005-01-01

    The first results of secondary electron images excited by 3-4.3 keV electrons are presented. The images are obtained with a standard FOCUS-PEEM set-up equipped with an imaging energy filter (IEF). The electron gun was mounted on a standard PEEM entrance flange at an angle of 25 deg. with respect to the sample surface. A low extraction voltage of 500 V was used to minimize the deflection of the electron beam by the PEEM extraction electrode. The secondary electron images are compared to photoelectron images excited by a standard 4.9 eV UV lamp. In the case of a Cu pattern on a Si substrate it is found that the lateral resolution without the IEF is about the same for electron and photon excitation but that the relative electron emission intensities are very different. The use of the IEF reduces the lateral resolution. Images for secondary electron energies between eV 1 and eV 2 were obtained by setting the IEF to -V 1 and -V 2 ∼-(V 1 +5V) potentials and taking the difference of both images. Images up to 100 eV electron energies were recorded. The material contrast obtained in these difference images is discussed in terms of a secondary electron and photoelectron emission model and secondary electron energy spectra measured with a LEED-Auger spectrometer

  3. Smoke, Biomass Exposure, and COPD Risk in the Primary Care Setting: The PUMA Study.

    Science.gov (United States)

    Montes de Oca, Maria; Zabert, Gustavo; Moreno, Dolores; Laucho-Contreras, Maria E; Lopez Varela, Maria Victorina; Surmont, Filip

    2017-08-01

    The evidence indicates that risk factors other than smoking are important in the development of COPD. It has been postulated that less traditional risk factors (eg, exposure to coal and/or biomass smoke) may interact with smoking to further increase COPD risk. This analysis evaluated the effect of exposure to biomass and smoking on COPD risk in a primary care setting in Latin America. Subjects attending routine primary care visits, ≥40 y old, who were current or former smokers or were exposed to biomass smoke, completed a questionnaire and performed spirometry. COPD was defined as post-bronchodilator FEV 1 /FVC 30), and biomass exposure was defined as an exposure to coal or wood (for heating, cooking, or both) for ≥ 10 y. One thousand seven hundred forty-three individuals completed the questionnaire, and 1,540 performed spirometry. Irrespective of COPD definition, approximately 40% of COPD subjects reported exposure to biomass versus 30% of those without COPD. A higher proportion of COPD subjects (post-bronchodilator FEV 1 /FVC 30 pack-years (66% vs 39%); similar results were found with the lower limit of normal definition. Analysis of exposure to biomass > 10 y plus smoking > 20 pack-years (reference was no exposure) found that tobacco smoking (crude odds ratio [OR] 4.50, 95% CI 2.73-7.41; adjusted OR 3.30, 95% CI 1.93-5.63) and biomass exposure (crude OR 3.66, 95% CI 2.00-6.73; adjusted OR 2.28, 95% CI 1.18-4.41) were risk factors for COPD, with smoking a possible confounder for the association between biomass and COPD (post-bronchodilator FEV 1 /FVC biomass and smoking compared with non-COPD subjects. Smoking and biomass are both risk factors for COPD, but they do not appear to have an additive effect. Copyright © 2017 by Daedalus Enterprises.

  4. Electromagnetic fields and the public: EMF standards and estimation of risk

    Science.gov (United States)

    Grigoriev, Yury

    2010-04-01

    Mobile communications are a relatively new and additional source of electromagnetic exposure for the population. Standard daily mobile-phone use is known to increase RF-EMF (radiofrequency electromagnetic field) exposure to the brains of users of all ages, whilst mobile-phone base stations, and base station units for cordless phones, can regularly increase the exposures of large numbers of the population to RF-EMF radiation in everyday life. The need to determine appropriate standards stipulating the maximum acceptable short-term and long-term RF-EMF levels encountered by the public, and set such levels as general guidelines, is of great importance in order to help preserve the general public's health and that of the next generation of humanity.

  5. Electromagnetic fields and the public: EMF standards and estimation of risk

    International Nuclear Information System (INIS)

    Grigoriev, Yury

    2010-01-01

    Mobile communications are a relatively new and additional source of electromagnetic exposure for the population. Standard daily mobile-phone use is known to increase RF-EMF (radiofrequency electromagnetic field) exposure to the brains of users of all ages, whilst mobile-phone base stations, and base station units for cordless phones, can regularly increase the exposures of large numbers of the population to RF-EMF radiation in everyday life. The need to determine appropriate standards stipulating the maximum acceptable short-term and long-term RF-EMF levels encountered by the public, and set such levels as general guidelines, is of great importance in order to help preserve the general public's health and that of the next generation of humanity.

  6. Asbestos Exposure Assessment Database

    Science.gov (United States)

    Arcot, Divya K.

    2010-01-01

    Exposure to particular hazardous materials in a work environment is dangerous to the employees who work directly with or around the materials as well as those who come in contact with them indirectly. In order to maintain a national standard for safe working environments and protect worker health, the Occupational Safety and Health Administration (OSHA) has set forth numerous precautionary regulations. NASA has been proactive in adhering to these regulations by implementing standards which are often stricter than regulation limits and administering frequent health risk assessments. The primary objective of this project is to create the infrastructure for an Asbestos Exposure Assessment Database specific to NASA Johnson Space Center (JSC) which will compile all of the exposure assessment data into a well-organized, navigable format. The data includes Sample Types, Samples Durations, Crafts of those from whom samples were collected, Job Performance Requirements (JPR) numbers, Phased Contrast Microscopy (PCM) and Transmission Electron Microscopy (TEM) results and qualifiers, Personal Protective Equipment (PPE), and names of industrial hygienists who performed the monitoring. This database will allow NASA to provide OSHA with specific information demonstrating that JSC s work procedures are protective enough to minimize the risk of future disease from the exposures. The data has been collected by the NASA contractors Computer Sciences Corporation (CSC) and Wyle Laboratories. The personal exposure samples were collected from devices worn by laborers working at JSC and by building occupants located in asbestos-containing buildings.

  7. Radiation cancer, safety standards and current levels of exposure

    International Nuclear Information System (INIS)

    Mole, R.H.

    1976-01-01

    Cancer can be induced by radiation in any tissue where cancer occurs naturally. The observation that antenatal diagnostic radiography causes a small but definite increase in childhood cancer is as good evidence as could be expected in support of the scientific expectation that there would be no threshold of dose for carcinogenesis. A linear relation between radiation dose and frequency of induced cancer is a necessary assumption for a system of radiological protection but is not necessarily a reasonable basis for realistic assessments of cancer risk. Indeed there are radiobiological and epidemiological reasons to the contrary. If the linear hypothesis is accepted then at the present time in the UK the routine practice of medicine is of about 2 orders of magnitude more important in causing cancer than environmental pollution by discharge of radio-activity. The acceptability of radiation safety standards for occupational exposure may be justified by comparison of radiation cancer risks with risks from fatal accidents in the safer industries. The acceptability of the corresponding standards for members of the public seems to require more public discussion of the concept of negligible risk. Emotional reactions to uncontrolled releases of radio-activity are based at least in part on a failure to appreciate the hypothesis of linearity

  8. Factors associated with secondhand smoke exposure in different settings: Results from the German Health Update (GEDA) 2012.

    Science.gov (United States)

    Fischer, Florian; Kraemer, Alexander

    2016-04-14

    The ubiquity of secondhand smoke (SHS) exposure at home or in private establishments, workplaces and public areas poses several challenges for the reduction of SHS exposure. This study aimed to describe the prevalence of SHS exposure in Germany and key factors associated with exposure. Results were also differentiated by place of exposure. A secondary data analysis based on the public use file of the German Health Update 2012 was conducted (n = 13,933). Only non-smokers were included in the analysis. In a multivariable logistic regression model the factors associated with SHS exposure were calculated. In addition, a further set of multivariable logistic regressions were calculated for factors associated with the place of SHS exposure (workplace, at home, bars/discotheques, restaurants, at the house of a friend). More than a quarter of non-smoking study participants were exposed to SHS. The main area of exposure was the workplace (40.9 %). The multivariable logistic regression indicated young age as the most important factor associated with SHS exposure. The odds for SHS exposure was higher in men than in women. The likelihood of SHS exposure decreased with higher education. SHS exposure and the associated factors varied between different places of exposure. Despite several actions to protect non-smokers which were implemented in Germany during the past years, SHS exposure still remains a relevant risk factor at a population level. According to the results of this study, particularly the workplace and other public places such as bars and discotheques have to be taken into account for the development of strategies to reduce SHS exposure.

  9. Correlates of exposure to second-hand smoke in an urban Mediterranean population

    Directory of Open Access Journals (Sweden)

    Borras Josep

    2007-08-01

    Full Text Available Abstract Background To describe the socio-demographic factors associated with exposure to second-hand smoke (SHS in different settings (home, leisure, and workplace. Methods We analysed cross-sectional data on self-reported SHS exposure in 1059 non-daily smokers interviewed in the Cornellà Health Interview Survey Follow-up Study in 2002. We calculated age-adjusted prevalence rates and prevalence rate ratios of SHS exposure at home, at the workplace, during leisure time, and in any of these settings. Results The age-standardized prevalence rate of SHS exposure in any setting was 69.5% in men and 62.9% in women. Among men, 25.9% reported passive smoking at home, 55.1% during leisure time, and 34.0% at the workplace. Among women, prevalence rates in these settings were 34.1%, 44.3% and 30.1%, respectively. Overall exposure to SHS decreased with age in both men and women. In men, SHS exposure was related to marital status, physical activity, smoking, and alcohol intake. In women, SHS exposure was related to educational level, marital status, occupational status, self-perceived health, smoking-related illness, and alcohol intake. Conclusion The prevalence of SHS exposure in this population was high. The strongest association with exposure were found for age and occupational status in men, and age and educational level in women.

  10. 75 FR 44589 - Health Information Technology: Initial Set of Standards, Implementation Specifications, and...

    Science.gov (United States)

    2010-07-28

    ... Part III Department of Health and Human Services 45 CFR Part 170 Health Information Technology... Secretary 45 CFR Part 170 RIN 0991-AB58 Health Information Technology: Initial Set of Standards... of the National Coordinator for Health Information Technology (ONC), Department of Health and Human...

  11. Digital blocks in Camac standard for synchrocyclotron investigations

    International Nuclear Information System (INIS)

    Zhuravlev, N.I.; Li Zu Ehk; Nguen Man' Shat; Petrov, A.G.

    1975-01-01

    Described are brief characteristics and block diagrams of the following 12 blocks in the CAMAC standard designed for experiments on a synchrocyclotron: output register, digital printout, frame controller, logic signal commutator, controlled delay, binary counters of 4 types, exposure-set counter, decimal counter with full indication and L signal grader

  12. How many standard area diagram sets are needed for accurate disease severity assessment

    Science.gov (United States)

    Standard area diagram sets (SADs) are widely used in plant pathology: a rater estimates disease severity by comparing an unknown sample to actual severities in the SADs and interpolates an estimate as accurately as possible (although some SADs have been developed for categorizing disease too). Most ...

  13. Assessing the reliability of the borderline regression method as a standard setting procedure for objective structured clinical examination

    Directory of Open Access Journals (Sweden)

    Sara Mortaz Hejri

    2013-01-01

    Full Text Available Background: One of the methods used for standard setting is the borderline regression method (BRM. This study aims to assess the reliability of BRM when the pass-fail standard in an objective structured clinical examination (OSCE was calculated by averaging the BRM standards obtained for each station separately. Materials and Methods: In nine stations of the OSCE with direct observation the examiners gave each student a checklist score and a global score. Using a linear regression model for each station, we calculated the checklist score cut-off on the regression equation for the global scale cut-off set at 2. The OSCE pass-fail standard was defined as the average of all station′s standard. To determine the reliability, the root mean square error (RMSE was calculated. The R2 coefficient and the inter-grade discrimination were calculated to assess the quality of OSCE. Results: The mean total test score was 60.78. The OSCE pass-fail standard and its RMSE were 47.37 and 0.55, respectively. The R2 coefficients ranged from 0.44 to 0.79. The inter-grade discrimination score varied greatly among stations. Conclusion: The RMSE of the standard was very small indicating that BRM is a reliable method of setting standard for OSCE, which has the advantage of providing data for quality assurance.

  14. Psychometric aspects of item mapping for criterion-referenced interpretation and bookmark standard setting.

    Science.gov (United States)

    Huynh, Huynh

    2010-01-01

    Locating an item on an achievement continuum (item mapping) is well-established in technical work for educational/psychological assessment. Applications of item mapping may be found in criterion-referenced (CR) testing (or scale anchoring, Beaton and Allen, 1992; Huynh, 1994, 1998a, 2000a, 2000b, 2006), computer-assisted testing, test form assembly, and in standard setting methods based on ordered test booklets. These methods include the bookmark standard setting originally used for the CTB/TerraNova tests (Lewis, Mitzel, Green, and Patz, 1999), the item descriptor process (Ferrara, Perie, and Johnson, 2002) and a similar process described by Wang (2003) for multiple-choice licensure and certification examinations. While item response theory (IRT) models such as the Rasch and two-parameter logistic (2PL) models traditionally place a binary item at its location, Huynh has argued in the cited papers that such mapping may not be appropriate in selecting items for CR interpretation and scale anchoring.

  15. Space Life Sciences at NASA: Spaceflight Health Policy and Standards

    Science.gov (United States)

    Davis, Jeffrey R.; House, Nancy G.

    2006-01-01

    In January 2005, the President proposed a new initiative, the Vision for Space Exploration. To accomplish the goals within the vision for space exploration, physicians and researchers at Johnson Space Center are establishing spaceflight health standards. These standards include fitness for duty criteria (FFD), permissible exposure limits (PELs), and permissible outcome limits (POLs). POLs delineate an acceptable maximum decrement or change in a physiological or behavioral parameter, as the result of exposure to the space environment. For example cardiovascular fitness for duty standards might be a measurable clinical parameter minimum that allows successful performance of all required duties. An example of a permissible exposure limit for radiation might be the quantifiable limit of exposure over a given length of time (e.g. life time radiation exposure). An example of a permissible outcome limit might be the length of microgravity exposure that would minimize bone loss. The purpose of spaceflight health standards is to promote operational and vehicle design requirements, aid in medical decision making during space missions, and guide the development of countermeasures. Standards will be based on scientific and clinical evidence including research findings, lessons learned from previous space missions, studies conducted in space analog environments, current standards of medical practices, risk management data, and expert recommendations. To focus the research community on the needs for exploration missions, NASA has developed the Bioastronautics Roadmap. The Bioastronautics Roadmap, NASA's approach to identification of risks to human space flight, revised baseline was released in February 2005. This document was reviewed by the Institute of Medicine in November 2004 and the final report was received in October 2005. The roadmap defines the most important research and operational needs that will be used to set policy, standards (define acceptable risk), and

  16. Using intranet-based order sets to standardize clinical care and prepare for computerized physician order entry.

    Science.gov (United States)

    Heffner, John E; Brower, Kathleen; Ellis, Rosemary; Brown, Shirley

    2004-07-01

    The high cost of computerized physician order entry (CPOE) and physician resistance to standardized care have delayed implementation. An intranet-based order set system can provide some of CPOE's benefits and offer opportunities to acculturate physicians toward standardized care. INTRANET CLINICIAN ORDER FORMS (COF): The COF system at the Medical University of South Carolina (MUSC) allows caregivers to enter and print orders through the intranet at points of care and to access decision support resources. Work on COF began in March 2000 with transfer of 25 MUSC paper-based order set forms to an intranet site. Physician groups developed additional order sets, which number more than 200. Web traffic increased progressively during a 24-month period, peaking at more than 6,400 hits per month to COF. Decision support tools improved compliance with Centers for Medicare & Medicaid Services core indicators. Clinicians demonstrated a willingness to develop and use order sets and decision support tools posted on the COF site. COF provides a low-cost method for preparing caregivers and institutions to adopt CPOE and standardization of care. The educational resources, relevant links to external resources, and communication alerts will all link to CPOE, thereby providing a head start in CPOE implementation.

  17. A Comparison of Standard-Setting Procedures for an OSCE in Undergraduate Medical Education.

    Science.gov (United States)

    Kaufman, David M.; Mann, Karen V.; Muijtjens, Arno M. M.; van der Vleuten, Cees P. M.

    2000-01-01

    Compared four standard-setting procedures for an objective structure clinical examination (OSCE) in medical education. Applied Angoff, borderline, relative, and holistic procedures to the data used to establish a cutoff score for a pass/fail decision. The Angoff and borderline procedures gave similar results; however, the relative and holistic…

  18. Setting a national minimum standard for health benefits: how do state benefit mandates compare with benefits in large-group plans?

    Science.gov (United States)

    Frey, Allison; Mika, Stephanie; Nuzum, Rachel; Schoen, Cathy

    2009-06-01

    Many proposed health insurance reforms would establish a federal minimum benefit standard--a baseline set of benefits to ensure that people have adequate coverage and financial protection when they purchase insurance. Currently, benefit mandates are set at the state level; these vary greatly across states and generally target specific areas rather than set an overall standard for what qualifies as health insurance. This issue brief considers what a broad federal minimum standard might look like by comparing existing state benefit mandates with the services and providers covered under the Federal Employees Health Benefits Program (FEHBP) Blue Cross and Blue Shield standard benefit package, an example of minimum creditable coverage that reflects current standard practice among employer-sponsored health plans. With few exceptions, benefits in the FEHBP standard option either meet or exceed those that state mandates require-indicating that a broad-based national benefit standard would include most existing state benefit mandates.

  19. Setting standards of restorative justice

    Directory of Open Access Journals (Sweden)

    Kostić Miomira

    2007-01-01

    Full Text Available In the article the author deals with the basic theoretical statements and discussions about the practical use of restorative justice. She discusses the questions of introducing and application of restorative justice in order to reach the balance of interests between a victim, society and a delinquent. There is no unique statement about the restorative justice concept, so the authors make this concept by listing certain activities with rispect of standards and principles. Also she emphasizes the values of restorative justice process. A part of the article is dedicated to the standards for restorative justice that are harmonized with the international documents of human rights. .

  20. ACCOUNTING STANDARD SETTING IN THE INTERNATIONAL ARENA: UPDATE ON THE CONVERGENCE PROJECT

    Directory of Open Access Journals (Sweden)

    Bonaci Carmen Giorgiana

    2012-07-01

    Full Text Available Our paper contributes to the literature on international accounting by focusing on the standard setting process. As documented by research literature, accounting regulation can enhance corporate governance (Melis and Carta, 2010, corporate reporting being expected to reduce information asymmetry. Based on accounting research and trade literature we first synthesize recent evolutions in the international accounting arena. We therefore position our study within current realities significantly marked by uncertainty in relation to the world wide globalization process. The objective of our paper is to perform an analysis that would help assess further developments of the convergence project. This is done by looking at the current status of the projects being developed under the IASB –FASB collaboration, as well as by developing a comparison between IFRS and US GAAP. The employed research methodology relies on analyzing data provided through the IASB and the FASB’s websites, as well as other official documents being issued by the two Boards. The assessment of the projects was done by reviewing exposure documents and monitoring the Boards’ deliberations, while the developed comparison requires accounting regulations content analysis. Concluding upon the Boards’ ongoing projects, we might identify areas in which convergence seems to be quite close (such as revenue recognition and leasing, but also areas in which convergence becomes even more challenging (such as financial instruments or the particular case of offsetting. Similar to other studies being developed within accounting research and trade literature (SEC 2011: 8 we may conclude that, generally, US GAAP present more detailed, specific requirements than IFRS.

  1. Development of spatial data guidelines and standards: spatial data set documentation to support hydrologic analysis in the U.S. Geological Survey

    Science.gov (United States)

    Fulton, James L.

    1992-01-01

    Spatial data analysis has become an integral component in many surface and sub-surface hydrologic investigations within the U.S. Geological Survey (USGS). Currently, one of the largest costs in applying spatial data analysis is the cost of developing the needed spatial data. Therefore, guidelines and standards are required for the development of spatial data in order to allow for data sharing and reuse; this eliminates costly redevelopment. In order to attain this goal, the USGS is expanding efforts to identify guidelines and standards for the development of spatial data for hydrologic analysis. Because of the variety of project and database needs, the USGS has concentrated on developing standards for documenting spatial sets to aid in the assessment of data set quality and compatibility of different data sets. An interim data set documentation standard (1990) has been developed that provides a mechanism for associating a wide variety of information with a data set, including data about source material, data automation and editing procedures used, projection parameters, data statistics, descriptions of features and feature attributes, information on organizational contacts lists of operations performed on the data, and free-form comments and notes about the data, made at various times in the evolution of the data set. The interim data set documentation standard has been automated using a commercial geographic information system (GIS) and data set documentation software developed by the USGS. Where possible, USGS developed software is used to enter data into the data set documentation file automatically. The GIS software closely associates a data set with its data set documentation file; the documentation file is retained with the data set whenever it is modified, copied, or transferred to another computer system. The Water Resources Division of the USGS is continuing to develop spatial data and data processing standards, with emphasis on standards needed to support

  2. Lead exposure in US worksites: A literature review and development of an occupational lead exposure database from the published literature

    Science.gov (United States)

    Koh, Dong-Hee; Locke, Sarah J.; Chen, Yu-Cheng; Purdue, Mark P.; Friesen, Melissa C.

    2016-01-01

    Background Retrospective exposure assessment of occupational lead exposure in population-based studies requires historical exposure information from many occupations and industries. Methods We reviewed published US exposure monitoring studies to identify lead exposure measurement data. We developed an occupational lead exposure database from the 175 identified papers containing 1,111 sets of lead concentration summary statistics (21% area air, 47% personal air, 32% blood). We also extracted ancillary exposure-related information, including job, industry, task/location, year collected, sampling strategy, control measures in place, and sampling and analytical methods. Results Measurements were published between 1940 and 2010 and represented 27 2-digit standardized industry classification codes. The majority of the measurements were related to lead-based paint work, joining or cutting metal using heat, primary and secondary metal manufacturing, and lead acid battery manufacturing. Conclusions This database can be used in future statistical analyses to characterize differences in lead exposure across time, jobs, and industries. PMID:25968240

  3. Secondhand Smoke Exposure and Smoke-Free Policy Support Among Public Housing Authority Residents in Rural and Tribal Settings.

    Science.gov (United States)

    Schmidt, Lisa M; Reidmohr, Alison A; Helgerson, Steven D; Harwell, Todd S

    2016-12-01

    Previous research has shown that multi-unit housing (MUH) residents are at risk of secondhand smoke (SHS) exposure, which can transfer between units. The purpose of this study was to determine SHS exposure and examine attitudes towards smoking policies among public housing authority (PHA) residents in rural and tribal settings. A self-administered questionnaire was completed by 895 adult tenants (41 % response rate) living in PHA multiunit buildings in Montana in 2013. Our primary outcome was tenant support of smoke-free policies; our secondary outcome was exacerbation of child asthma symptoms due to SHS exposure. In 2014, we used multiple logistic regression models to test associations between independent variables and outcomes of interest. The majority (80.6 %) of respondents supported having a smoke-free policy in their building, with support being significantly higher among nonsmokers [adjusted odds ratio (aOR) 4.2, 95 % confidence interval (CI) 1.5-11.6] and among residents living with children (aOR 2.9, 95 % CI 1.3-6.2). Tribal residents were as likely to support smoke-free policies as non-tribal residents (aOR 1.4; 95 % CI 0.5-4.0). Over half (56.5 %) of respondents reported SHS exposure in their home; residents in a building with no smoke-free policy in place were significantly more likely to report exposure (aOR 3.5, 95 % CI 2.2-5.5). SHS exposure was not significantly associated with asthma symptoms. There is a significant reduction in exposure to SHS in facilities with smoke-free policies and there is strong support for such policies by both tribal and non-tribal MUH residents. Opportunities exist for smoke-free policy initiatives in rural and tribal settings.

  4. Standard precautions: occupational exposure and behavior of health care workers in Ethiopia.

    Directory of Open Access Journals (Sweden)

    Ayalu A Reda

    2010-12-01

    Full Text Available Occupational exposure to blood and body fluids is a serious concern for health care workers, and presents a major risk for the transmission of infections such as HIV and hepatitis viruses. The objective of this study was to investigate occupational exposures and behavior of health care workers (HCWs in eastern Ethiopia.We surveyed 475 HCWs working in 10 hospitals and 20 health centers in eastern Ethiopia using a structured questionnaire with a response rate of 84.4%. Descriptive statistics and multivariate analysis using logistic regression were performed.Life time risks of needle stick (30.5%; 95% CI 26.4-34.6% and sharps injuries (25.7%; 95% CI 21.8-29.6% were high. The one year prevalence of needle stick and sharps injury were 17.5% (95% CI 14.1-20.9% and 13.5% (95% CI 10.4-16.6% respectively. There was a high prevalence of life time (28.8%; 95% CI = 24.7-32.9% and one year (20.2%; 95% CI = 16.6-23.8% exposures to blood and body fluids. Two hundred thirteen (44.8% HCWs reported that they were dissatisfied by the supply of infection prevention materials. HCWs had sub-optimal practices and unfavorable attitudes related to standard precautions such as needle recapping (46.9% and discriminatory attitudes (30.5% toward HIV/AIDS patients.There was a high level of exposure to blood and body fluids among HCWs. We detected suboptimal practices and behavior that put both patients and HCWs at significant risk of acquiring occupational infections. Health authorities in the study area need to improve the training of HCWs and provision of infection prevention equipment. In addition, regular reporting and assessment of occupational exposures need to be implemented.

  5. Determination of size-specific exposure settings in dental cone-beam CT

    International Nuclear Information System (INIS)

    Pauwels, Ruben; Jacobs, Reinhilde; Bogaerts, Ria; Bosmans, Hilde; Panmekiate, Soontra

    2017-01-01

    To estimate the possible reduction of tube output as a function of head size in dental cone-beam computed tomography (CBCT). A 16 cm PMMA phantom, containing a central and six peripheral columns filled with PMMA, was used to represent an average adult male head. The phantom was scanned using CBCT, with 0-6 peripheral columns having been removed in order to simulate varying head sizes. For five kV settings (70-90 kV), the mAs required to reach a predetermined image noise level was determined, and corresponding radiation doses were derived. Results were expressed as a function of head size, age, and gender, based on growth reference charts. The use of 90 kV consistently resulted in the largest relative dose reduction. A potential mAs reduction ranging from 7 % to 50 % was seen for the different simulated head sizes, showing an exponential relation between head size and mAs. An optimized exposure protocol based on head circumference or age/gender is proposed. A considerable dose reduction, through reduction of the mAs rather than the kV, is possible for small-sized patients in CBCT, including children and females. Size-specific exposure protocols should be clinically implemented. (orig.)

  6. Determination of size-specific exposure settings in dental cone-beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Pauwels, Ruben [Chulalongkorn University, Department of Radiology, Faculty of Dentistry, Patumwan, Bangkok (Thailand); University of Leuven, OMFS-IMPATH Research Group, Department of Imaging and Pathology, Biomedical Sciences Group, Leuven (Belgium); Jacobs, Reinhilde [University of Leuven, OMFS-IMPATH Research Group, Department of Imaging and Pathology, Biomedical Sciences Group, Leuven (Belgium); Bogaerts, Ria [University of Leuven, Laboratory of Experimental Radiotherapy, Department of Oncology, Biomedical Sciences Group, Leuven (Belgium); Bosmans, Hilde [University of Leuven, Medical Physics and Quality Assessment, Department of Imaging and Pathology, Biomedical Sciences Group, Leuven (Belgium); Panmekiate, Soontra [Chulalongkorn University, Department of Radiology, Faculty of Dentistry, Patumwan, Bangkok (Thailand)

    2017-01-15

    To estimate the possible reduction of tube output as a function of head size in dental cone-beam computed tomography (CBCT). A 16 cm PMMA phantom, containing a central and six peripheral columns filled with PMMA, was used to represent an average adult male head. The phantom was scanned using CBCT, with 0-6 peripheral columns having been removed in order to simulate varying head sizes. For five kV settings (70-90 kV), the mAs required to reach a predetermined image noise level was determined, and corresponding radiation doses were derived. Results were expressed as a function of head size, age, and gender, based on growth reference charts. The use of 90 kV consistently resulted in the largest relative dose reduction. A potential mAs reduction ranging from 7 % to 50 % was seen for the different simulated head sizes, showing an exponential relation between head size and mAs. An optimized exposure protocol based on head circumference or age/gender is proposed. A considerable dose reduction, through reduction of the mAs rather than the kV, is possible for small-sized patients in CBCT, including children and females. Size-specific exposure protocols should be clinically implemented. (orig.)

  7. New Zealanders working non-standard hours also have greater exposure to other workplace hazards.

    Science.gov (United States)

    Jay, Sarah M; Gander, Philippa H; Eng, Amanda; Cheng, Soo; Douwes, Jeroen; Ellison-Loschmann, Lis; McLean, Dave; Pearce, Neil; 'tMannetje, Andrea

    2017-01-01

    Exposure to workplace hazards, such as dust, solvents, and fumes, has the potential to adversely affect the health of people. However, the effects of workplace hazards on health may differ when exposure occurs at different times in the circadian cycle, and among people who work longer hours or who do not obtain adequate sleep. The aim of the present study was to document exposures to workplace hazards across a national sample of New Zealanders, comparing people who work a standard 08:00 -17:00 h Monday-to-Friday working week (Std hours) and those who do not (N-Std hours). New Zealanders (n = 10 000) aged 20-64 yrs were randomly selected from the Electoral Roll to take part in a nationwide survey of workplace exposures. Telephone interviews were conducted between 2004 and 2006, using a six-part questionnaire addressing demographics, detailed information on the current or most recent job (including exposures to a range of workplace hazards), sleep, sleepiness, and health status. N-Std hours were categorised on the basis of: being required to start work prior to 07:00 h or finish work after 21:00 h and/or; having a regular on-call commitment (at least once per week) and/or; working rotating shifts and/or; working night shift(s) in the last month. The response rate was 37% (n = 3003), with 22.2% of participants (n = 656) categorised as working N-Std hours. Industry sectors with the highest numbers of participants working N-Std hours were manufacturing, health and community services, and agriculture, fishing, and forestry. Response rate was 37% (n = 3003) with 22.2% (n = 656) categorised as working N-Std hours. Participants working N-Std hours were more likely to be exposed to all identified hazards, including multiple hazards (OR = 2.45, 95% CI = 2.01-3.0) compared to those working Std hours. Participants working N-Std hours were also more likely to report 'never/rarely' getting enough sleep (OR = 1.38, 95% CI = 1.15-1.65), 'never/rarely' waking refreshed (OR = 1

  8. A Comparison of Image Quality and Radiation Exposure Between the Mini C-Arm and the Standard C-Arm.

    Science.gov (United States)

    van Rappard, Juliaan R M; Hummel, Willy A; de Jong, Tijmen; Mouës, Chantal M

    2018-04-01

    The use of intraoperative fluoroscopy has become mandatory in osseous hand surgery. Due to its overall practicality, the mini C-arm has gained popularity among hand surgeons over the standard C-arm. This study compares image quality and radiation exposure for patient and staff between the mini C-arm and the standard C-arm, both with flat panel technology. An observer-based subjective image quality study was performed using a contrast detail (CD) phantom. Five independent observers were asked to determine the smallest circles discernable to them. The results were plotted in a graph, forming a CD curve. From each curve, an image quality figure (IQF) was derived. A lower IQF equates to a better image quality. The patients' entrance skin dose was measured, and to obtain more information about the staff exposure dose, a perspex hand phantom was used. The scatter radiation was measured at various distances and angles relative to a central point on the detector. The IQF was significantly lower for the mini C-arm resulting in a better image quality. The patients' entrance dose was 10 times higher for the mini C-arm as compared with the standard C-arm, and the scatter radiation threefold. Due to its improved image quality and overall practicality, the mini C-arm is recommended for hand surgical procedures. To ensure that the surgeons' radiation exposure is not exceeding the safety limits, monitoring radiation exposure using mini C-arms with flat panel technology during surgery should be done in a future clinical study.

  9. Standard practice for conducting atmospheric corrosion tests on metals

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice covers and defines conditions for exposure of metals and alloys to the weather. It sets forth the general procedures that should be followed in any atmospheric test. It is presented as an aid in conducting atmospheric corrosion tests so that some of the pitfalls of such testing may be avoided. As such, it is concerned mainly with panel exposures to obtain data for comparison purposes. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of whoever uses this standard to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Gas industry standards board: Legal considerations in the standard setting process

    Energy Technology Data Exchange (ETDEWEB)

    Mishkin, M.T.; Adelman, D.I.

    1994-01-01

    On December 23, 1993, the Federal Energy Regulatory Commission (FERC) issued Order 563, a Final Rule adopting the agreements of informal industry-wide working groups to standardize information relating to pipeline capacity release programs mandated under Order 636. Order 563 is noteworthy for its reliance upon the industry to develop consensus standards for Commission adoption. The industry's success in reaching agreements on key communication standards issues spawned recommendations from the working groups to continue the development and maintenance of industry-wide standards through a permanent Gas Industry Standards Board (GISB). This article examines legal issues bearing on GISB's potential role in the regulatory process. Specifically, this article addresses constitutional and statutory considerations relating to the FERC's authority to delegate certain responsibilities to a voluntary, industry sponsored and supported private body such as that taking shape within the gas industry.

  11. Integrated methodology for standard-setting norms of innovative product in the new competitive environment

    Science.gov (United States)

    Polyakova, Marina; Rubin, Gennadiy

    2017-07-01

    Modern theory of technological and economical development is based on long-term cycles. So far it has been proved that the technological structure of the economy can be subdivided into groups of technological complexes, which are inter-related with each other by similar technological links, so called technological modes. Technological mode is defined as a complex of interrelated production units of similar technological level, which develop simultaneously. In order to provide competitiveness of products in the new changing conditions, it is necessary to make sure that they meet all the regulatory requirements specified in standards. But the existing and the fast changing situation on the merchandise markets causes disbalance between the growing customer requirements and the technological capabilities of the manufacturer. This makes the issue of standardization development even more urgent both from the point of view of establishing the current positions and from the point of view of possible promising development trends in technology. In the paper scientific and engineering principles of developing standardization as a science are described. It is shown that further development of standardization is based on the principles of advanced standardization the main idea of which is to set up the prospective requirements to the innovative product. Modern approaches of advanced standardization are shown in this paper. The complexity of the negotiation procedure between customer and manufacturer as a whole and achieving of consensus, in particular, make it necessary to find conceptually new approaches to developing mathematical models. The developed methodology picture the process of achieving the consensus between customer and manufacturer while developing the standard norms in the form of decreasing S-curve diagram. It means that in the end of the negotiation process, there is no difference between customer and manufacturer positions. It makes it possible to provide the

  12. Set up and operation for medical radiation exposure quality control system of health promotion center

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Su; Kim, Jung Min [Korea University,Seoul (Korea, Republic of); Jung, Hae Kyoung [Dept. of Diagnostic Radiology, CHA Bundang Medical Center, CHA University, Sungnam (Korea, Republic of)

    2016-03-15

    In this study, standard model of medical radiation dosage quality control system will be suggested and the useful of this system in clinical field will be reviewed. Radiation dosage information of modalities are gathered from digital imaging and communications in medicine(DICOM) standard data(such as DICOM dose SR and DICOM header) and stored in database. One CT scan, two digital radiography modalities and two mammography modalities in one health promotion center in Seoul are used to derive clinical data for one month. After 1 months research with 703 CT scans, the study shows CT 357.9 mGy·cm in abdomen and pelvic CT, 572.4 mGy·cm in brain without CT, 55.9 mGy·cm in calcium score/heart CT, screening CT at 54 mGy·cm in chest screening CT(low dose screening CT scan), 284.99 mGy·cm in C-spine CT and 341.85 mGy·cm in L-spine CT as health promotion center reference level of each exam. And with 1955 digital radiography cases, it shows 274.0 mGy·cm{sup 2} and for mammography 6.09 mGy is shown based on 536 cases. The use of medical radiation shall comply with the principles of justification and optimization. This quality management of medical radiation exposure must be performed in order to follow the principle. And the procedure to reduce the radiation exposure of patients and staff can be achieved through this. The results of this study can be applied as a useful tool to perform the quality control of medical radiation exposure.

  13. Set up and operation for medical radiation exposure quality control system of health promotion center

    International Nuclear Information System (INIS)

    Kim, Jung Su; Kim, Jung Min; Jung, Hae Kyoung

    2016-01-01

    In this study, standard model of medical radiation dosage quality control system will be suggested and the useful of this system in clinical field will be reviewed. Radiation dosage information of modalities are gathered from digital imaging and communications in medicine(DICOM) standard data(such as DICOM dose SR and DICOM header) and stored in database. One CT scan, two digital radiography modalities and two mammography modalities in one health promotion center in Seoul are used to derive clinical data for one month. After 1 months research with 703 CT scans, the study shows CT 357.9 mGy·cm in abdomen and pelvic CT, 572.4 mGy·cm in brain without CT, 55.9 mGy·cm in calcium score/heart CT, screening CT at 54 mGy·cm in chest screening CT(low dose screening CT scan), 284.99 mGy·cm in C-spine CT and 341.85 mGy·cm in L-spine CT as health promotion center reference level of each exam. And with 1955 digital radiography cases, it shows 274.0 mGy·cm"2 and for mammography 6.09 mGy is shown based on 536 cases. The use of medical radiation shall comply with the principles of justification and optimization. This quality management of medical radiation exposure must be performed in order to follow the principle. And the procedure to reduce the radiation exposure of patients and staff can be achieved through this. The results of this study can be applied as a useful tool to perform the quality control of medical radiation exposure

  14. SU-E-I-27: Establishing Target Exposure Index Values for Computed Radiography

    International Nuclear Information System (INIS)

    Murphy, N; Tchou, P; Belcher, K; Scott, A

    2014-01-01

    Purpose: To develop a standard set of target exposure index (TEI) values to be applied to Agfa Computed Radiography (CR) readers in accordance with International Electrotechnical Committee 62494-1 (ed. 1.0). Methods: A large data cohort was collected from six USAF Medical Treatment Facilities that exclusively use Agfa CR Readers. Dose monitoring statistics were collected from each reader. The data was analyzed based on anatomic region, view, and processing speed class. The Agfa specific exposure metric, logarithmic mean (LGM), was converted to exposure index (EI) for each data set. The optimum TEI value was determined by minimizing the number of studies that fell outside the acceptable deviation index (DI) range of +/− 2 for phototimed techniques or a range of +/−3 for fixed techniques. An anthropomorphic radiographic phantom was used to corroborate the TEI recommendations. Images were acquired of several anatomic regions and views using standard techniques. The images were then evaluated by two radiologists as either acceptable or unacceptable. The acceptable image with the lowest exposure and EI value was compared to the recommended TEI values using a passing DI range. Results: Target EI values were determined for a comprehensive list of anatomic regions and views. Conclusion: Target EI values must be established on each CR unit in order to provide a positive feedback system for the technologist. This system will serve as a mechanism to prevent under or overexposures of patients. The TEI recommendations are a first attempt at a large scale process improvement with the goal of setting reasonable and standardized TEI values. The implementation and effectiveness of the recommended TEI values should be monitored and adjustments made as necessary

  15. Kinetic Analysis of the Multivalent Ligand Binding Interaction between Protein A/G and IgG: A Standard System Setting.

    Science.gov (United States)

    Reader, Peter P; Shaw, Andrew M

    2017-09-28

    Recombinant protein A/G (PAG) has a sequence coding for eight IgG binding sites and has enhanced interspecies affinity. High-frequency sampling of a PAG titration with IgG produces concentration profiles that are sensitive to the kinetic availability of the binding sites. The full kinetic model developed here for IgG binding sequentially to PAG shows only two distinct kinetic processes, describing an initial rapid association of two antibodies to PAG with a rate constant k-fast = (1.86 ± 0.08) × 10 6 M -1 s -1 and a slower antibody binding process to all remaining sites, k-slow = (1.24 ± 0.05) × 10 4 M -1 s -1 . At equilibrium (after 1 h), the maximum IgG occupancy of PAG is 2.8 ± 0.5, conflicting with the genetic evidence of eight binding sites and suggesting significant steric hindrance of the neighboring IgG binding sites. The phosphate-buffered saline (PBS) solution defines a standard system setting, and this may be compared with other settings. The mean association rate of PAG-IgG n in the standard setting is 282 ± 20% higher than when PAG is tethered to a surface. A systems biology approach requires that a model parameter set that defines a system in a standard setting should be transferable to another system. The transfer of parameters between settings may be performed using activity coefficients characterizing an effective concentration of species in a system, a i = γ i c i . The activity correction, γ, for the eight-site occupancy is γ = 0.35 ± 0.06, and mapping from the standard setting to the solution setting suggests γ PAG-IgG = 0.4 ± 0.03. The role of activity coefficients and transferability of kinetic parameters between system settings is discussed.

  16. Setting Proficiency Standards for School Leadership Assessment: An Examination of Cut Score Decision Making

    Science.gov (United States)

    Cravens, Xiu Chen; Goldring, Ellen B.; Porter, Andrew C.; Polikoff, Morgan S.; Murphy, Joseph; Elliott, Stephen N.

    2013-01-01

    Purpose: Performance evaluation informs professional development and helps school personnel improve student learning. Although psychometric literature indicates that a rational, sound, and coherent standard-setting process adds to the credibility of an assessment, few studies have empirically examined the decision-making process. This article…

  17. A standardized set of 3-D objects for virtual reality research and applications.

    Science.gov (United States)

    Peeters, David

    2018-06-01

    The use of immersive virtual reality as a research tool is rapidly increasing in numerous scientific disciplines. By combining ecological validity with strict experimental control, immersive virtual reality provides the potential to develop and test scientific theories in rich environments that closely resemble everyday settings. This article introduces the first standardized database of colored three-dimensional (3-D) objects that can be used in virtual reality and augmented reality research and applications. The 147 objects have been normed for name agreement, image agreement, familiarity, visual complexity, and corresponding lexical characteristics of the modal object names. The availability of standardized 3-D objects for virtual reality research is important, because reaching valid theoretical conclusions hinges critically on the use of well-controlled experimental stimuli. Sharing standardized 3-D objects across different virtual reality labs will allow for science to move forward more quickly.

  18. The report of medical exposures in diagnostic radiology. Pt. 1. The questionnaire of medical exposure and standard radiation exposure

    International Nuclear Information System (INIS)

    Sasakawa, Yasuhiro; Matsumura, Yoshitaka; Iwasaki, Takanobu; Segawa, Hiroo; Yasuda, Sadatoshi; Kusuhara, Toshiaki

    1997-01-01

    We had made reports of patient radiation exposure for doctors to judge adaptation of medical radiation rightly. By these reports the doctors can be offered data of exposure dose and somatic effect. First, we sent out questionnaires so that we grasped the doctor's understanding about radiation exposure. Consequently we understood that the doctors had demanded data of exposure dose and somatic effect. Secondly, by the result of questionnaires we made the tables of exposure dose about radiological examination. As a result we have be able to presume exposure dose about high radiation sensitive organization as concrete figures. (author)

  19. Beyond crosswalks: reliability of exposure assessment following automated coding of free-text job descriptions for occupational epidemiology.

    Science.gov (United States)

    Burstyn, Igor; Slutsky, Anton; Lee, Derrick G; Singer, Alison B; An, Yuan; Michael, Yvonne L

    2014-05-01

    Epidemiologists typically collect narrative descriptions of occupational histories because these are less prone than self-reported exposures to recall bias of exposure to a specific hazard. However, the task of coding these narratives can be daunting and prohibitively time-consuming in some settings. The aim of this manuscript is to evaluate the performance of a computer algorithm to translate the narrative description of occupational codes into standard classification of jobs (2010 Standard Occupational Classification) in an epidemiological context. The fundamental question we address is whether exposure assignment resulting from manual (presumed gold standard) coding of the narratives is materially different from that arising from the application of automated coding. We pursued our work through three motivating examples: assessment of physical demands in Women's Health Initiative observational study, evaluation of predictors of exposure to coal tar pitch volatiles in the US Occupational Safety and Health Administration's (OSHA) Integrated Management Information System, and assessment of exposure to agents known to cause occupational asthma in a pregnancy cohort. In these diverse settings, we demonstrate that automated coding of occupations results in assignment of exposures that are in reasonable agreement with results that can be obtained through manual coding. The correlation between physical demand scores based on manual and automated job classification schemes was reasonable (r = 0.5). The agreement between predictive probability of exceeding the OSHA's permissible exposure level for polycyclic aromatic hydrocarbons, using coal tar pitch volatiles as a surrogate, based on manual and automated coding of jobs was modest (Kendall rank correlation = 0.29). In the case of binary assignment of exposure to asthmagens, we observed that fair to excellent agreement in classifications can be reached, depending on presence of ambiguity in assigned job classification (κ

  20. Evolution of the concept of reduction the exposure levels to natural radiation and the new international standards in protection of radon

    International Nuclear Information System (INIS)

    Pavlovic, R.; Pavlovic, S.

    1995-01-01

    The new scientific information in last decade have caused significant changes in radiation protection standards. The subject of reduction the exposure to natural radiation is now regulated in more details. Some new aspects in protection against Rn exposure at home and work are discussed. (author)

  1. 76 FR 28036 - Request for Comments and Announcement of Workshop on Standard-Setting Issues

    Science.gov (United States)

    2011-05-13

    ... costs resulting from hold-up. Collaborative standard setting plays an important role in the modern... process, and does not require a full search of the firm's patent portfolio. Many rules encourage... excluding patent applications from disclosure or by not requiring members to search their patent portfolios...

  2. Effects of setting new source performance standards for fluidized-bed combustion systems

    Energy Technology Data Exchange (ETDEWEB)

    1978-02-01

    This study was undertaken for the US Environmental Protection Agency to examine the potential consequences of revisions in New Source Performance Standards (NSPS) on fluidized-bed combustor-based steam electric generators of greater than 250,000,000 Btu. A study of the appropriateness and differential effects of alternate regulatory approaches to the standards-setting process was made. Problems dealing with an emerging technology such as fluidized-bed combustion were emphasized. Finally, an examination was made of the potential benefits of fluidized-bed combustion (FBC) systems relative to conventional coal-fired systems equipped with scrubbers. Information is included on the relative advantages and disadvantages of utility-sized fluidized-bed combustors, the technical consequences of NSPS alternatives, policy implications concerning NSPS for steam-electric generators, and cost models for atmospheric and pressurized FBC systems. (LCL)

  3. Results from a Community-Wide Pilot Program to Standardize COPD Education for Patients Across Healthcare Settings in Rhode Island.

    Science.gov (United States)

    Pelland, Kimberly; Youssef, Rouba; Calandra, Kathleen; Cellar, Jennifer; Thiesen, Jennifer; Gardner, Rebekah

    2017-07-05

    Chronic obstructive pulmonary disease (COPD) is associated with significant morbidity, decreased quality of life, and burdensome hospital admissions. Therefore, patients with COPD interact with clinicians in a number of healthcare settings. A coalition of healthcare practitioners in Rhode Island, in partnership with the local Quality Improvement Organization, designed and implemented a standardized, COPD education program for use across multiple healthcare settings. More than 60 organizations participated, producing 140 Master Trainers, who trained 634 staff members at their facilities from October 2015 through June 2016. Master Trainers were satisfied with the training, and we observed significant increases in knowledge scores post-training among all participants, which remained significant when stratified by setting. These results demonstrate that implementation of a community-based program to disseminate patient-centered, standardized COPD education in multiple healthcare settings is feasible. We hope this program will ultimately improve patient outcomes and serve as the foundation for expanding standardized education for other chronic conditions. [Full article available at http://rimed.org/rimedicaljournal-2017-07.asp].

  4. Radiobiological basis for setting neutron radiation safety standards

    International Nuclear Information System (INIS)

    Straume, T.

    1985-01-01

    Present neutron standards, adopted more than 20 yr ago from a weak radiobiological data base, have been in doubt for a number of years and are currently under challenge. Moreover, recent dosimetric re-evaluations indicate that Hiroshima neutron doses may have been much lower than previously thought, suggesting that direct data for neutron-induced cancer in humans may in fact not be available. These recent developments make it urgent to determine the extent to which neutron cancer risk in man can be estimated from data that are available. Two approaches are proposed here that are anchored in particularly robust epidemiological and experimental data and appear most likely to provide reliable estimates of neutron cancer risk in man. The first approach uses gamma-ray dose-response relationships for human carcinogenesis, available from Nagasaki (Hiroshima data are also considered), together with highly characterized neutron and gamma-ray data for human cytogenetics. When tested against relevant experimental data, this approach either adequately predicts or somewhat overestimates neutron tumorigenesis (and mutagenesis) in animals. The second approach also uses the Nagasaki gamma-ray cancer data, but together with neutron RBEs from animal tumorigenesis studies. Both approaches give similar results and provide a basis for setting neutron radiation safety standards. They appear to be an improvement over previous approaches, including those that rely on highly uncertain maximum neutron RBEs and unnecessary extrapolations of gamma-ray data to very low doses. Results suggest that, at the presently accepted neutron dose limit of 0.5 rad/yr, the cancer mortality risk to radiation workers is not very different from accidental mortality risks to workers in various nonradiation occupations

  5. Current exposure method for CCP’s under Basel III

    Directory of Open Access Journals (Sweden)

    Antonie Kotzé

    2013-04-01

    Full Text Available Exposure-at-default is one of the most interesting and most difficult parameters to estimate in counterparty credit risk. Basel I offered only the non-internal Current Exposure Method for estimating this quantity whilst Basel II further introduced the Standardized Method and an Internal Model Method. Under new Basel III rules a central counterparty is defined as being a financial institution. New principles set out by the Basel Committee on Banking Supervision forces Central Counterparties in using the Current Exposure Method when estimating the credit exposures to Clearing Member banks notwithstanding its shortcomings. The Current Exposure Method relies on the Value-at-Risk methodology and its characteristics are discussed in this note. We will particularly investigate exposures to SAFCOM, the South African clearing house and point to a mathematical discrepancy on how netting is effected through the Basel accord.

  6. [Development of a software standardizing optical density with operation settings related to several limitations].

    Science.gov (United States)

    Tu, Xiao-Ming; Zhang, Zuo-Heng; Wan, Cheng; Zheng, Yu; Xu, Jin-Mei; Zhang, Yuan-Yuan; Luo, Jian-Ping; Wu, Hai-Wei

    2012-12-01

    To develop a software that can be used to standardize optical density to normalize the procedures and results of standardization in order to effectively solve several problems generated during standardization of in-direct ELISA results. The software was designed based on the I-STOD method with operation settings to solve the problems that one might encounter during the standardization. Matlab GUI was used as a tool for the development. The software was tested with the results of the detection of sera of persons from schistosomiasis japonica endemic areas. I-STOD V1.0 (WINDOWS XP/WIN 7, 0.5 GB) was successfully developed to standardize optical density. A serial of serum samples from schistosomiasis japonica endemic areas were used to examine the operational effects of I-STOD V1.0 software. The results indicated that the software successfully overcame several problems including reliability of standard curve, applicable scope of samples and determination of dilution for samples outside the scope, so that I-STOD was performed more conveniently and the results of standardization were more consistent. I-STOD V1.0 is a professional software based on I-STOD. It can be easily operated and can effectively standardize the testing results of in-direct ELISA.

  7. Youth Exposure to Violence in an Urban Setting

    OpenAIRE

    Seal, David; Nguyen, Annie; Beyer, Kirsten

    2014-01-01

    To inform a city-wide youth Violence Prevention Initiative, we explored youth narratives about their exposure to violence to gain insight into their understanding of the causes and effects of violence in their communities. At-risk youth were recruited through street outreach for individual interviews and focus group sessions. Types of experiential violence identified included (1) street, (2) family/interpersonal, (3) school, (4) indirect exposure (e.g., neighborhood crime), and (5) prejudice/...

  8. Radiation dosimetry and standards at the austrian dosimetry laboratory

    International Nuclear Information System (INIS)

    Leitner, A.

    1984-10-01

    The Austrian Dosimetry Laboratory, established and operated in cooperation between the Austrian Research Center Seibersdorf and the Federal Office of Metrology and Surveying (Bundesamt and Eich- und Vermessungswesen) maintains the national primary standards for radiation dosimetry. Furthermore its tasks include routine calibration of dosemeters and dosimetric research. The irradiation facilities of the laboratory comprise three X-ray machines covering the voltage range from 5 kV to 420 kV constant potential, a 60 Co teletherapy unit, a circular exposure system for routine batch calibration of personnel dosemeters with four gamma ray sources ( 60 Co and 137 Cs) and a reference source system with six gamma ray sources ( 60 Co and 137 Cs). In addition a set of calibrated beta ray sources are provided ( 147 Pm, 204 Tl and 90 Sr). The dosimetric equipment consists of three free-air parallelplate ionization chambers serving as primary standards of exposure for the X-ray energy region, graphite cavity chambers with measured volume as primary standards for the gamma radiation of 137 Cs and 60 Co as well as different secondary standard ionization chambers covering the dose rate range from the natural background level up to the level of modern therapy accelerators. In addition for high energy photon and electron radiation a graphite calorimeter is provided as primary standard of absorbed dose. The principle experimental set-ups for the practical use of the standards are presented and the procedures for the calibration of the different types of dosemeters are described. (Author)

  9. OSHA Bloodborne Pathogens Standards Exposure Control Plan

    Science.gov (United States)

    Luhrs, Caro Elise; Teitelbaum, Rita

    1993-01-01

    The Hummer Associates Exposure Control Plan is designed to reduce significant occupational exposure to bloodborne pathogens and infectious materials for Hummer Associates health care personnel. Under universal precautions, all patients and all body fluids are considered potentially infectious for bloodborne pathogens. Medical personnel need not be at increased risk if universal precautions are correctly understood and followed. This program covers all employees who could reasonably anticipate contact with blood or other potentially infectious materials during the performance of their job responsibilities. Although HIV and hepatitis B are mentioned most often, this program applies to all bloodborne diseases. The two main components needed to implement this program are universal precautions and engineering/work practice controls. This program covers all employees who may have occupational exposure to blood or other potentially infectious materials. Other aspects of this program are discussed.

  10. Standardized network order sets in rural Ontario: a follow-up report on successes and sustainability.

    Science.gov (United States)

    Rawn, Andrea; Wilson, Katrina

    2011-01-01

    Unifying, implementing and sustaining a large order set project requires strategic placement of key organizational professionals to provide ongoing user education, communication and support. This article will outline the successful strategies implemented by the Grey Bruce Health Network, Evidence-Based Care Program to reduce length of stay, increase patient satisfaction and increase the use of best practices resulting in quality outcomes, safer practice and better allocation of resources by using standardized Order Sets within a network of 11 hospital sites. Audits conducted in 2007 and again in 2008 revealed a reduced length of stay of 0.96 in-patient days when order sets were used on admission and readmission for the same or a related diagnosis within one month decreased from 5.5% without order sets to 3.5% with order sets.

  11. Detecting intrajudge inconsistency in standard setting using test items with a selected-response format

    NARCIS (Netherlands)

    van der Linden, Willem J.; Vos, Hendrik J.; Chang, Lei

    2002-01-01

    In judgmental standard setting experiments, it may be difficult to specify subjective probabilities that adequately take the properties of the items into account. As a result, these probabilities are not consistent with each other in the sense that they do not refer to the same borderline level of

  12. The regulatory framework of accounting and accounting standard-setting bodies in the European Union member states

    Directory of Open Access Journals (Sweden)

    Ivana Mamić-Sačer

    2015-12-01

    Full Text Available One of the principal features of accounting in the 21st century is harmonisation and stanardisation. Regulation of the European Parliament and European Council No. 1606/2002 harmonizes financial reporting for certain companies in the EU. However, national accounting principles are of great importance for financial reporting. The main purpose of this research was to investigate the application of generally accepted accounting principles, the regulatory accounting framework and the standard-setting bodies of EU member states. The analysis of these accounting issues was conducted with respect to all 28 EU member states. The results indicate that EU member states regulate their principal accounting issues through separate accounting acts or implement those issues in companies acts. Some EU member states do not have national accounting standards, the national accounting principles being incorporated in companies acts and accounting acts. Nevertheless, national accounting standard-setting bodies are governmental organisations in almost half the member states.

  13. Air crew exposure on board a subsonic aircraft studied with complex dosimetric sets

    International Nuclear Information System (INIS)

    Spurny, F.; Votockova, I.; Bottollier-Depois, J.F.

    1996-01-01

    Radiation fields on board a subsonic aircraft have been studied using a complex set of measuring instruments i.e. tissue equivalent proportional counter (TEPC), neutron rem-meter, environmental radiation dose rate meter, thermoluminescent detectors (TLDs), track etch detectors (TEDs) and bubble damage neutron detectors (BDNDs). The measurements have been realised on board the Airbus A310-300 during the flights Prague-Montreal and Montreal-Prague, in February 1995. The results obtained are presented, analysed and discussed both from the point of view of the detector responses and the general exposure levels. (authors). 23 refs., 1 fig., 4 tabs

  14. The Common Core State Standards' Quantitative Text Complexity Trajectory: Figuring out How Much Complexity Is Enough

    Science.gov (United States)

    Williamson, Gary L.; Fitzgerald, Jill; Stenner, A. Jackson

    2013-01-01

    The Common Core State Standards (CCSS) set a controversial aspirational, quantitative trajectory for text complexity exposure for readers throughout the grades, aiming for all high school graduates to be able to independently read complex college and workplace texts. However, the trajectory standard is presented without reference to how the…

  15. Setting Standards: Three Tales and a Proposition

    DEFF Research Database (Denmark)

    Knudsen, Mette Præst; Nielsen, Jørgen Ulff-Møller; Pedersen, Kurt

    2001-01-01

    Technological development has a tendency to be reflected in standards. In some cases, the market is the vehicle for defining standards that will be the outcome of a competitive battle between (groups of) firms. In other cases authorities will attempt to influence the technology process - and the ......Technological development has a tendency to be reflected in standards. In some cases, the market is the vehicle for defining standards that will be the outcome of a competitive battle between (groups of) firms. In other cases authorities will attempt to influence the technology process...... - and the standards. The background may be industry policy in combination with the nature of the technology and the products. The battle thus may turn into a battle between the market and the administrators. This paper presents three industry cases, one representing the pure market solution, and two presenting...... conflicts of interests; both leading to the final victory for the market driven solution....

  16. The 1998 calibration of Australian secondary standards of exposure and absorbed dose at 60Co

    International Nuclear Information System (INIS)

    Huntley, R.B.; Van der Gaast, H.

    1998-10-01

    New calibration factors are reported for several of the ionization chambers maintained at the Australian Radiation Laboratory (ARL) and at the Australian Nuclear Science and Technology Organisation (ANSTO) as Australian secondary standards of exposure/air kerma and absorbed dose at 60 Co. These calibration factors supplement or replace the calibration factors given in earlier reports. Updated 90 Sr reference source data are given for the ARL chambers, and for two of the ANSTO chambers. These results confirm the stability of the secondary standards. A re-calibration of the ANSTO reference electrometer is reported. This was carried out using an improved method, which is fully described

  17. Standard practice for exposing and evaluating metals and alloys in surface seawater

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This practice covers conditions for the exposure of metals, alloys, and other materials in natural surface seawater such as those typically found in bays, harbors, channels, and so forth, as contrasted with deep ocean testing. This practice covers full immersion, tidal zone and related splash, and spray zone exposures. 1.2 This practice sets forth general procedures that should be followed in conducting seawater exposure tests so that meaningful comparisons may be made from one location to another. 1.3 This practice identifies recommended procedures for evaluating the effects of natural surface seawater on the materials exposed. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regula...

  18. Incorporating Measurement Error from Modeled Air Pollution Exposures into Epidemiological Analyses.

    Science.gov (United States)

    Samoli, Evangelia; Butland, Barbara K

    2017-12-01

    Outdoor air pollution exposures used in epidemiological studies are commonly predicted from spatiotemporal models incorporating limited measurements, temporal factors, geographic information system variables, and/or satellite data. Measurement error in these exposure estimates leads to imprecise estimation of health effects and their standard errors. We reviewed methods for measurement error correction that have been applied in epidemiological studies that use model-derived air pollution data. We identified seven cohort studies and one panel study that have employed measurement error correction methods. These methods included regression calibration, risk set regression calibration, regression calibration with instrumental variables, the simulation extrapolation approach (SIMEX), and methods under the non-parametric or parameter bootstrap. Corrections resulted in small increases in the absolute magnitude of the health effect estimate and its standard error under most scenarios. Limited application of measurement error correction methods in air pollution studies may be attributed to the absence of exposure validation data and the methodological complexity of the proposed methods. Future epidemiological studies should consider in their design phase the requirements for the measurement error correction method to be later applied, while methodological advances are needed under the multi-pollutants setting.

  19. Are we ready to apply the de minimis concept to standard setting: a historical approach

    International Nuclear Information System (INIS)

    Stannard, J.N.

    1984-01-01

    The pros and cons of the de minimis concept is discussed from a historical point of view. The purpose is first to indicate how long ago many common occupational hazards were recognized and second to conclude that there had to be exposure levels that were essentially trivial, i.e., de minimis. Some aspects of the history of radiation protection are presented. The topics of discussion include: empiricism; the tolerance dose; the maximum permissible exposure dose; as low as possible dose (ALAP) and as low as reasonable achievable (ALARA); and the challenge of the '80s. In the '80s with the strong movement to use risk as a basis for both radiation and chemical standards, the need for adding the concept of a trivial risk has taken hold. Some examples of possible de minimis levels, as well as some of the problems and current activities, are presented

  20. Dealing of embryo/fetal exposures in a medical setting

    International Nuclear Information System (INIS)

    Miller, K.L.

    1991-01-01

    The medical environment presents two uniquely different situations involving potential radiation exposure to the embryo or fetus. On the one hand we have the potential for radiation exposure to the embryo of fetus of the occupationally exposed employee where the recommendations are well defined. On the other hand we have the pregnant or potentially pregnant patient requiring diagnostic radiological examinations or therapeutic procedures where the recommendations are not as well defined. This paper provides an overview of both situations, a discussion of potential exposures and a review of methods for estimating fetal doses when the exposed individual is the patient

  1. Policy issues in setting de minimis standards for latent cancer risks of radiation and chemical carcinogens

    International Nuclear Information System (INIS)

    Spangler, M.

    1984-01-01

    In the fuel cycles for the development and utilization of alternative energy resources, the risk of latent cancer arises from a number of sources. Included are ionizing radiation and the carcinogenic potential of polluting chemicals present in certain fuels or in materials associated with the construction, operation, maintenance or waste treatment processes of nuclear power, fossil fuels, synfuels, biomass, and other sources of energy. One aspect of developing a carcinogen guideline policy for a consistent and effective regulatory regime to use in dealing with these assorted carcinogenic risks is the setting of de minimis quantitative standards. In this report, 11 policy issues related to the setting of such regulatory standards are identified and a brief commentary is provided. 15 references, 1 table

  2. The role of cellular and molecular studies in evaluation of health effects from combined radiation and chemical exposures

    International Nuclear Information System (INIS)

    Brooks, A.L.; Gilbert, E.S.; Kitchin, R.M.; Johnson, N.F.

    1992-06-01

    Additive models are currently used to predict risks following exposure to multiple agents or complex mixtures. Use of these models is questioned because different methods are used to derive risks for chemical and physical agents depending on the database used. Risks for the induction of cancer from radiation are based on large sets of human data, while standards are set for most chemical carcinogens using information derived from animal studies. However, it is not, from a scientific point of view, appropriate to add risks from physical and chemical agents to derive potential health impact from combined exposures. The range of safety factors built into the estimates, the large differences in the data sets used to evaluate and establish standards, and the differences in the basic philosophy for deriving risks for physical and chemical agents make the additive model unacceptable for estimating risks from combined exposures. To understand the potential health impacts from environmental exposure, it is important (1) to consider how risks were derived and (2) to determine if interactions exist between damage induced by the different agents to ensure that additive assumptions are valid. This presentation discusses a number of these safety factors for specific chemicals

  3. Mind-sets, low-level exposures, and research

    International Nuclear Information System (INIS)

    Sagan, L.A.

    1993-01-01

    Much of our environmental policy is based on the notion that carcinogenic agents are harmful at even minuscule doses. From where does this thinking come? What is the scientific evidence that supports such policy? Moreover, why is the public willing to buy into this? Or is it the other way around: Has the scientific community bought into a paradigm that has its origins in public imagery? Or, most likely, are there interactions between the two? It is essential that we find out whether or not there are risks associated with low-level exposures to radiation. The author can see three obvious areas where the future depends on better information: The increasing radiation exposures resulting from the use of medical diagnostic and therapeutic practices need to be properly evaluated for safety; Environmental policies, which direct enormous resources to the reduction of small radiation exposures, needs to be put on a firmer scientific basis; The future of nuclear energy, dependent as it is on public acceptance, may well rely upon a better understanding of low-dose effects. Nuclear energy could provide an important solution of global warming and other possible environmental hazards, but will probably not be implemented as long as fear of low-dose radiation persists. Although an established paradigm has great resilience, it cannot resist the onslaught of inconsistent scientific observations or of the social value system that supports it. Only new research will enable us to determine if a paradigm shift is in order here

  4. Effect of exposure to evening light on sleep initiation in the elderly: a longitudinal analysis for repeated measurements in home settings.

    Science.gov (United States)

    Obayashi, Kenji; Saeki, Keigo; Iwamoto, Junko; Okamoto, Nozomi; Tomioka, Kimiko; Nezu, Satoko; Ikada, Yoshito; Kurumatani, Norio

    2014-05-01

    Epidemiologic data have demonstrated associations of sleep-onset insomnia with a variety of diseases, including depression, dementia, diabetes and cardiovascular diseases. Sleep initiation is controlled by the suprachiasmatic nucleus of the hypothalamus and endogenous melatonin, both of which are influenced by environmental light. Exposure to evening light is hypothesized to cause circadian phase delay and melatonin suppression before bedtime, resulting in circadian misalignment and sleep-onset insomnia; however, whether exposure to evening light disturbs sleep initiation in home settings remains unclear. In this longitudinal analysis of 192 elderly individuals (mean age: 69.9 years), we measured evening light exposure and sleep-onset latency for 4 days using a wrist actigraph incorporating a light meter and an accelerometer. Mixed-effect linear regression analysis for repeated measurements was used to evaluate the effect of evening light exposure on subsequent sleep-onset latency. The median intensity of evening light exposure and the median sleep-onset latency were 27.3 lux (interquartile range, 17.9-43.4) and 17 min (interquartile range, 7-33), respectively. Univariate models showed significant associations between sleep-onset latency and age, gender, daytime physical activity, in-bed time, day length and average intensity of evening and nighttime light exposures. In a multivariate model, log-transformed average intensity of evening light exposure was significantly associated with log-transformed sleep-onset latency independent of the former potential confounding factors (regression coefficient, 0.133; 95% CI, 0.020-0.247; p = 0.021). Day length and nighttime light exposure were also significantly associated with log-transformed sleep-onset latency (p = 0.001 and p < 0.001, respectively). In conclusion, exposure to evening light in home setting prolongs subsequent sleep-onset latency in the elderly.

  5. Alleged B. anthracis exposure claims in a workers' compensation setting.

    Science.gov (United States)

    Jewell, Gregory; Dunning, Kari; Lockey, James E

    2006-01-01

    Workers' compensation insurance in some states may not provide coverage for medical evaluation costs of workplace exposures related to potential bioterrorism acts if there is no diagnosed illness or disease. Personal insurance also may not provide coverage for these exposures occurring at the workplace. Governmental entities, insurers, and employers need to consider how to address such situations and the associated costs. The objective of this study was to examine characteristics of workers and total costs associated with workers' compensation claims alleging potential exposure to the bioterrorism organism B. anthracis. We examined 192 claims referred for review to the Ohio Bureau of Workers' Compensation (OBWC) from October 10, 2001, through December 20, 2004. Although some cases came from out-of-state areas where B. anthracis exposure was known to exist, no Ohio claim was associated with true B. anthracis exposure or B. anthracis-related illness. Of the 155 eligible claims, 126 included medical costs averaging dollar 219 and ranging from dollar 24 to dollar 3,126. There was no difference in mean cost for government and non-government employees (p = 0.202 Wilcoxon). The number of claims and associated medical costs for evaluation and treatment of potential workplace exposure to B. anthracis were relatively small. These results can be attributed to several factors, including no documented B. anthracis exposures and disease in Ohio and prompt transmission of recommended diagnostic and prophylactic treatment protocols to physicians. How employers, insurers, and jurisdictions address payment for evaluation and treatment of potential or documented exposures resulting from a potential terrorism-related event should be addressed proactively.

  6. Environmental radiation standards

    International Nuclear Information System (INIS)

    Kocher, D.C.

    1987-01-01

    This document contains an outline of an oral presentation on environmental radiation standards presented to the American Nuclear Societies' Topical Conference on Population Exposure from the Nuclear Fuel Cycle. The paper contains several definitions, a summary of current radiation exposure limits; and numerous proposed changes to current standards. 7 figs

  7. Preschool Children's Exposure to Media, Technology, and Screen Time: Perspectives of Caregivers from Three Early Childcare Settings

    Science.gov (United States)

    Sharkins, Kimberly A.; Newton, Allison B.; Albaiz, Najla Essa A.; Ernest, James M.

    2016-01-01

    Young children are being increasingly exposed to media, technology, and screen time (MeTS) at home and in instructional settings. Little is known about the long-term effects of MeTS and there is a lack of research concerning caregivers' opinions regarding young children's exposure to and utilization of MeTS. Therefore, this study explored the…

  8. Search for the standard model Higgs Boson produced in association with top quarks using the full CDF data set.

    Science.gov (United States)

    Aaltonen, T; Álvarez González, B; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Apollinari, G; Appel, J A; Arisawa, T; Artikov, A; Asaadi, J; Ashmanskas, W; Auerbach, B; Aurisano, A; Azfar, F; Badgett, W; Bae, T; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Barria, P; Bartos, P; Bauce, M; Bedeschi, F; Behari, S; Bellettini, G; Bellinger, J; Benjamin, D; Beretvas, A; Bhatti, A; Bisello, D; Bizjak, I; Bland, K R; Blumenfeld, B; Bocci, A; Bodek, A; Bortoletto, D; Boudreau, J; Boveia, A; Brigliadori, L; Bromberg, C; Brucken, E; Budagov, J; Budd, H S; Burkett, K; Busetto, G; Bussey, P; Buzatu, A; Calamba, A; Calancha, C; Camarda, S; Campanelli, M; Campbell, M; Canelli, F; Carls, B; Carlsmith, D; Carosi, R; Carrillo, S; Carron, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavaliere, V; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, K; Chokheli, D; Chung, W H; Chung, Y S; Ciocci, M A; Clark, A; Clarke, C; Compostella, G; Connors, J; Convery, M E; Conway, J; Corbo, M; Cordelli, M; Cox, C A; Cox, D J; Crescioli, F; Cuevas, J; Culbertson, R; Dagenhart, D; d'Ascenzo, N; Datta, M; de Barbaro, P; Dell'Orso, M; Demortier, L; Deninno, M; Devoto, F; d'Errico, M; Di Canto, A; Di Ruzza, B; Dittmann, J R; D'Onofrio, M; Donati, S; Dong, P; Dorigo, M; Dorigo, T; Ebina, K; Elagin, A; Eppig, A; Erbacher, R; Errede, S; Ershaidat, N; Eusebi, R; Farrington, S; Feindt, M; Fernandez, J P; Field, R; Flanagan, G; Forrest, R; Frank, M J; Franklin, M; Freeman, J C; Funakoshi, Y; Furic, I; Gallinaro, M; Garcia, J E; Garfinkel, A F; Garosi, P; Gerberich, H; Gerchtein, E; Giagu, S; Giakoumopoulou, V; Giannetti, P; Gibson, K; Ginsburg, C M; Giokaris, N; Giromini, P; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldin, D; Goldschmidt, N; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Goulianos, K; Grinstein, S; Grosso-Pilcher, C; Group, R C; Guimaraes da Costa, J; Hahn, S R; Halkiadakis, E; Hamaguchi, A; Han, J Y; Happacher, F; Hara, K; Hare, D; Hare, M; Harr, R F; Hatakeyama, K; Hays, C; Heck, M; Heinrich, J; Herndon, M; Hewamanage, S; Hocker, A; Hopkins, W; Horn, D; Hou, S; Hughes, R E; Hurwitz, M; Husemann, U; Hussain, N; Hussein, M; Huston, J; Introzzi, G; Iori, M; Ivanov, A; James, E; Jang, D; Jayatilaka, B; Jeon, E J; Jindariani, S; Jones, M; Joo, K K; Jun, S Y; Junk, T R; Kamon, T; Karchin, P E; Kasmi, A; Kato, Y; Ketchum, W; Keung, J; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, S B; Kim, S H; Kim, Y K; Kim, Y J; Kimura, N; Kirby, M; Klimenko, S; Knoepfel, K; Kondo, K; Kong, D J; Konigsberg, J; Kotwal, A V; Kreps, M; Kroll, J; Krop, D; Kruse, M; Krutelyov, V; Kuhr, T; Kurata, M; Kwang, S; Laasanen, A T; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; Lecompte, T; Lee, E; Lee, H S; Lee, J S; Lee, S W; Leo, S; Leone, S; Lewis, J D; Limosani, A; Lin, C-J; Lindgren, M; Lipeles, E; Lister, A; Litvintsev, D O; Liu, C; Liu, H; Liu, Q; Liu, T; Lockwitz, S; Loginov, A; Lucchesi, D; Lueck, J; Lujan, P; Lukens, P; Lungu, G; Lys, J; Lysak, R; Madrak, R; Maeshima, K; Maestro, P; Malik, S; Manca, G; Manousakis-Katsikakis, A; Margaroli, F; Marino, C; Martínez, M; Mastrandrea, P; Matera, K; Mattson, M E; Mazzacane, A; Mazzanti, P; McFarland, K S; McIntyre, P; McNulty, R; Mehta, A; Mehtala, P; Mesropian, C; Miao, T; Mietlicki, D; Mitra, A; Miyake, H; Moed, S; Moggi, N; Mondragon, M N; Moon, C S; Moore, R; Morello, M J; Morlock, J; Movilla Fernandez, P; Mukherjee, A; Muller, Th; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Naganoma, J; Nakano, I; Napier, A; Nett, J; Neu, C; Neubauer, M S; Nielsen, J; Nodulman, L; Noh, S Y; Norniella, O; Oakes, L; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Orava, R; Ortolan, L; Pagan Griso, S; Pagliarone, C; Palencia, E; Papadimitriou, V; Paramonov, A A; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Pianori, E; Pilot, J; Pitts, K; Plager, C; Pondrom, L; Poprocki, S; Potamianos, K; Prokoshin, F; Pranko, A; Ptohos, F; Punzi, G; Rahaman, A; Ramakrishnan, V; Ranjan, N; Redondo, I; Renton, P; Rescigno, M; Riddick, T; Rimondi, F; Ristori, L; Robson, A; Rodrigo, T; Rodriguez, T; Rogers, E; Rolli, S; Roser, R; Ruffini, F; Ruiz, A; Russ, J; Rusu, V; Safonov, A; Sakumoto, W K; Sakurai, Y; Santi, L; Sato, K; Saveliev, V; Savoy-Navarro, A; Schlabach, P; Schmidt, A; Schmidt, E E; Schwarz, T; Scodellaro, L; Scribano, A; Scuri, F; Seidel, S; Seiya, Y; Semenov, A; Sforza, F; Shalhout, S Z; Shears, T; Shepard, P F; Shimojima, M; Shochet, M; Shreyber-Tecker, I; Simonenko, A; Sinervo, P; Sliwa, K; Smith, J R; Snider, F D; Soha, A; Sorin, V; Song, H; Squillacioti, P; Stancari, M; St Denis, R; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Strycker, G L; Sudo, Y; Sukhanov, A; Suslov, I; Takemasa, K; Takeuchi, Y; Tang, J; Tecchio, M; Teng, P K; Thom, J; Thome, J; Thompson, G A; Thomson, E; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Totaro, P; Trovato, M; Ukegawa, F; Uozumi, S; Varganov, A; Vázquez, F; Velev, G; Vellidis, C; Vidal, M; Vila, I; Vilar, R; Vizán, J; Vogel, M; Volpi, G; Wagner, P; Wagner, R L; Wakisaka, T; Wallny, R; Wang, S M; Warburton, A; Waters, D; Wester, W C; Whiteson, D; Wicklund, A B; Wicklund, E; Wilbur, S; Wick, F; Williams, H H; Wilson, J S; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, H; Wright, T; Wu, X; Wu, Z; Yamamoto, K; Yamato, D; Yang, T; Yang, U K; Yang, Y C; Yao, W-M; Yeh, G P; Yi, K; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Yu, S S; Yun, J C; Zanetti, A; Zeng, Y; Zhou, C; Zucchelli, S

    2012-11-02

    A search is presented for the standard model Higgs boson produced in association with top quarks using the full Run II proton-antiproton collision data set, corresponding to 9.45 fb(-1), collected by the Collider Detector at Fermilab. No significant excess over the expected background is observed, and 95% credibility-level upper bounds are placed on the cross section σ(ttH → lepton + missing transverse energy+jets). For a Higgs boson mass of 125 GeV/c(2), we expect to set a limit of 12.6 and observe a limit of 20.5 times the standard model rate. This represents the most sensitive search for a standard model Higgs boson in this channel to date.

  9. Official American Thoracic Society technical standards: spirometry in the occupational setting.

    Science.gov (United States)

    Redlich, Carrie A; Tarlo, Susan M; Hankinson, John L; Townsend, Mary C; Eschenbacher, William L; Von Essen, Susanna G; Sigsgaard, Torben; Weissman, David N

    2014-04-15

    This document addresses aspects of the performance and interpretation of spirometry that are particularly important in the workplace, where inhalation exposures can affect lung function and cause or exacerbate lung diseases, such as asthma, chronic obstructive pulmonary disease, or fibrosis. Issues that previous American Thoracic Society spirometry statements did not adequately address with respect to the workplace were identified for systematic review. Medline 1950-2012 and Embase 1980-2012 were searched for evidence related to the following: training for spirometry technicians; testing posture; appropriate reference values to use for Asians in North America; and interpretative strategies for analyzing longitudinal change in lung function. The evidence was reviewed and technical recommendations were developed. Spirometry performed in the work setting should be part of a comprehensive workplace respiratory health program. Effective technician training and feedback can improve the quality of spirometry testing. Posture-related changes in FEV1 and FVC, although small, may impact interpretation, so testing posture should be kept consistent and documented on repeat testing. Until North American Asian-specific equations are developed, applying a correction factor of 0.88 to white reference values is considered reasonable when testing Asian American individuals in North America. Current spirometry should be compared with previous tests. Excessive loss in FEV1 over time should be evaluated using either a percentage decline (15% plus loss expected due to aging) or one of the other approaches discussed, taking into consideration testing variability, worker exposures, symptoms, and other clinical information. Important aspects of workplace spirometry are discussed and recommendations are provided for the performance and interpretation of workplace spirometry.

  10. International comparison of calibration standards for exposure and absorbed dose

    International Nuclear Information System (INIS)

    Horakova, I.; Wagner, R.

    1990-01-01

    A comparison was performed of the primary calibration standards for 60 Co gamma radiation dose from Czechoslovakia (UDZ CSAV, Prague), Austria (OEFZS/BEV Seibersdorf) and Hungary (OMH Budapest) using ND 1005 (absolute measurement) and V-415 (by means of N x ) graphite ionization chambers. BEV achieved agreement better than 0.1%, OMH 0.35%. Good agreement was also achieved for the values of exposure obtained in absolute values and those obtained via N x , this for the ND 1005/8105 chamber. The first ever international comparison involving Czechoslovakia was also performed of the unit of absorbed gamma radiation in a water and/or graphite phantom. The participants included Czechoslovakia (UDZ CSAV Prague), the USSR (VNIIFTRI Moscow) and Austria (OEFZS/BEV Seibersdorf). In all measurements, the agreement was better than 1%, which, in view of the differences in methodologies (VNIIFTRI, BEV: calorimetry, UDZ, UVVVR: ionometry) and the overall inaccuracies in determining the absorbed dose values, is a good result. (author)

  11. Exposure of medical students to pharmaceutical marketing in primary care settings: frequent and influential.

    Science.gov (United States)

    Sarikaya, Ozlem; Civaner, Murat; Vatansever, Kevser

    2009-12-01

    It is known that interaction between pharmaceutical companies and medical professionals may lead to corruption of professional values, irrational use of medicine, and negative effects on the patient-physician relationship. Medical students frequently interact with pharmaceutical company representatives and increasingly accept their gifts. Considering the move toward early clinical encounters and community-based education, which expose students early to pharmaceutical representatives, the influence of those gifts is becoming a matter of concern. This study examines the frequency and influence of student exposure to drug marketing in primary care settings, as well as student perceptions of physician-pharmaceutical company relationships. This was a two-phase study consisting of qualitative research followed by a cross-sectional survey. Clinical experience logbooks of 280 second-year students in one school were analysed, and the themes that emerged were used to develop a survey that was administered to 308 third-year students from two medical schools. Survey results showed a 91.2% exposure to any type of marketing, and 56.8% of students were exposed to all classes of marketing methods studied. Deliberate targeting of students by pharmaceutical representatives, in particular, was correlated with being less sensitive to the negative effects of and having positive opinions about interactions with pharmaceutical companies. The vast majority of students are exposed to drug marketing in primary care settings, and may become more vulnerable to that strategy. Considering that medical students are vulnerable and are targeted deliberately by pharmaceutical companies, interventions aimed at developing skills in the rational use of medicines and in strategies for coping with drug marketing should be devised.

  12. Experiencing a probabilistic approach to clarify and disclose uncertainties when setting occupational exposure limits.

    Science.gov (United States)

    Vernez, David; Fraize-Frontier, Sandrine; Vincent, Raymond; Binet, Stéphane; Rousselle, Christophe

    2018-03-15

    Assessment factors (AFs) are commonly used for deriving reference concentrations for chemicals. These factors take into account variabilities as well as uncertainties in the dataset, such as inter-species and intra-species variabilities or exposure duration extrapolation or extrapolation from the lowest-observed-adverse-effect level (LOAEL) to the noobserved- adverse-effect level (NOAEL). In a deterministic approach, the value of an AF is the result of a debate among experts and, often a conservative value is used as a default choice. A probabilistic framework to better take into account uncertainties and/or variability when setting occupational exposure limits (OELs) is presented and discussed in this paper. Each AF is considered as a random variable with a probabilistic distribution. A short literature was conducted before setting default distributions ranges and shapes for each AF commonly used. A random sampling, using Monte Carlo techniques, is then used for propagating the identified uncertainties and computing the final OEL distribution. Starting from the broad default distributions obtained, experts narrow it to its most likely range, according to the scientific knowledge available for a specific chemical. Introducing distribution rather than single deterministic values allows disclosing and clarifying variability and/or uncertainties inherent to the OEL construction process. This probabilistic approach yields quantitative insight into both the possible range and the relative likelihood of values for model outputs. It thereby provides a better support in decision-making and improves transparency. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  13. Conduct of operations: establishing operational focus and setting operational standards

    International Nuclear Information System (INIS)

    Lane, L.; McGuigan, K.

    1998-01-01

    Due to the nature of our business, we have often tended to focus on the technological aspects of the nuclear industry. The focus of this paper is directed towards the importance of addressing the people skills, attitudes, and 'culture' within, and surrounding, our facilities as key areas of improvement. Within Ontario Hydro Nuclear (OLIN) we have developed the terminology 'event free' operation and 'event free' culture. 'Event Free' recognizes errors as a part of human performance. 'Event Free' takes into account human weaknesses, and provides tools (such as standards) to manage, control, and mitigate errors. In essence, 'Event Free' encompasses two concepts: 1. Prevent errors from occurring; 2. If an error is made, catch it before it can affect safe operation of the facility, learn from the error, and ensure that it does not happen again. In addressing these business realities, Ontario Hydro has identified a number of key support mechanisms and corresponding performance standards that are essential for achieving operating excellence and an 'event free' business culture. This paper will discuss two operational aspects of an 'event free' culture, the first being a set of expectations to enhance the culture, and the second an example of cultural change: 1. Operating Standards - establishing clear expectations for human performance in operating staff; 2. Operational Focus - the understanding that, as a nuclear worker, you should consider every task, activity, in fact everything you do in this business, for the potential to affect safe and reliable operation of a nuclear facility. Note that although the term 'Operational' appears in the title, this concept applies to every individual in the nuclear business, from the cleaner, to the Board of Directors, to the external supplier. (author)

  14. PROCAL: A Set of 40 Peptide Standards for Retention Time Indexing, Column Performance Monitoring, and Collision Energy Calibration.

    Science.gov (United States)

    Zolg, Daniel Paul; Wilhelm, Mathias; Yu, Peng; Knaute, Tobias; Zerweck, Johannes; Wenschuh, Holger; Reimer, Ulf; Schnatbaum, Karsten; Kuster, Bernhard

    2017-11-01

    Beyond specific applications, such as the relative or absolute quantification of peptides in targeted proteomic experiments, synthetic spike-in peptides are not yet systematically used as internal standards in bottom-up proteomics. A number of retention time standards have been reported that enable chromatographic aligning of multiple LC-MS/MS experiments. However, only few peptides are typically included in such sets limiting the analytical parameters that can be monitored. Here, we describe PROCAL (ProteomeTools Calibration Standard), a set of 40 synthetic peptides that span the entire hydrophobicity range of tryptic digests, enabling not only accurate determination of retention time indices but also monitoring of chromatographic separation performance over time. The fragmentation characteristics of the peptides can also be used to calibrate and compare collision energies between mass spectrometers. The sequences of all selected peptides do not occur in any natural protein, thus eliminating the need for stable isotope labeling. We anticipate that this set of peptides will be useful for multiple purposes in individual laboratories but also aiding the transfer of data acquisition and analysis methods between laboratories, notably the use of spectral libraries. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Twelve-month follow-up of virtual reality and standard exposure therapies for the fear of flying.

    Science.gov (United States)

    Rothbaum, Barbara Olasov; Hodges, Larry; Anderson, Page L; Price, Larry; Smith, Samantha

    2002-04-01

    This study reports the 12-month follow-up from patients with the fear of flying who were treated in a controlled study and randomly assigned (n = 49) to virtual reality exposure (VRE) therapy, standard exposure (SE) therapy, or to a wait-list control (WL). VRE and SE were equally superior to WL. At 12 months posttreatment, data were gathered on 24 of the 30 (80%) patients who were assigned to VRE or SE. Patients maintained their treatment gains, and 92% of VRE participants and 91% of SE participants had flown on a real airplane since the graduation flight. This is the 1st year-long follow-up of patients having been treated with VRE and indicates that short-term treatment can have lasting effects.

  16. Reduced-dose chest CT with 3D automatic exposure control vs. standard chest CT: Quantitative assessment of emphysematous changes in smokers’ lung parenchyma

    International Nuclear Information System (INIS)

    Koyama, Hisanobu; Ohno, Yoshiharu; Yamazaki, Youichi; Matsumoto, Keiko; Onishi, Yumiko; Takenaka, Daisuke; Yoshikawa, Takeshi; Nishio, Mizuho; Matsumoto, Sumiaki; Murase, Kenya; Nishimura, Yoshihiro

    2012-01-01

    Objectives: To determine the capability of reduced-dose chest CT with three-dimensional (3D) automatic exposure control (AEC) on quantitative assessment of emphysematous change in smoker’ lung parenchyma, compared to standard chest CT. Methods: Twenty consecutive smoker patients (mean age 62.8 years) underwent CT examinations using a standard protocol (150 mAs) and a protocol with 3D-AEC. In this study, the targeted standard deviations number was set to 160. For quantitative assessment of emphysematous change in lung parenchyma in each subject using the standard protocol, a percentage of voxels less than −950 HU in the lung (%LAA −950 ) was calculated. The 3D-AEC protocol's %LAA was computed from of voxel percentages under selected threshold CT value. The differences of radiation doses between these two protocols were evaluated, and %LAAs −950 was compared with the 3D-AEC protocol %LAAs. Results: Mean dose length products were 780.2 ± 145.5 mGy cm (standard protocol), and 192.0 ± 95.9 (3D-AEC protocol). There was significant difference between them (paired Student's t test, p −950 and 3D-AEC protocol %LAAs. In adopting the feasible threshold CT values of the 3D-AEC protocol, the 3D-AEC protocol %LAAs were significantly correlated with %LAAs −950 (r = 0.98, p < 0.001) and limits of agreement from Bland–Altman analysis was 0.52 ± 4.3%. Conclusions: Changing threshold CT values demonstrated that reduced-dose chest CT with 3D-AEC can substitute for the standard protocol in assessments of emphysematous change in smoker’ lung parenchyma.

  17. British Standard method for determination of ISO speed and average gradient of direct-exposure medical and dental radiographic film/process combinations

    International Nuclear Information System (INIS)

    1983-01-01

    Under the direction of the Cinematography and Photography Standards Committee, a British Standard method has been prepared for determining ISO speed and average gradient of direct-exposure medical and dental radiographic film/film-process combinations. The method determines the speed and gradient, i.e. contrast, of the X-ray films processed according to their manufacturer's recommendations. (U.K.)

  18. Comparison study of judged clinical skills competence from standard setting ratings generated under different administration conditions.

    Science.gov (United States)

    Roberts, William L; Boulet, John; Sandella, Jeanne

    2017-12-01

    When the safety of the public is at stake, it is particularly relevant for licensing and credentialing exam agencies to use defensible standard setting methods to categorize candidates into competence categories (e.g., pass/fail). The aim of this study was to gather evidence to support change to the Comprehensive Osteopathic Medical Licensing-USA Level 2-Performance Evaluation standard setting design and administrative process. Twenty-two video recordings of candidates assessed for clinical competence were randomly selected from the 2014-2015 Humanistic domain test score distribution ranging from the highest to lowest quintile of performance. Nineteen panelists convened at the same site to receive training and practice prior to generating judgments of qualified or not qualified performance to each of the twenty videos. At the end of training, one panel remained onsite to complete their judgments and the second panel was released and given 1 week to observe the same twenty videos and complete their judgments offsite. The two one-sided test procedure established equivalence between panel group means at the 0.05 confidence level, controlling for rater errors within each panel group. From a practical cost-effective and administrative resource perspective, results from this study suggest it is possible to diverge from typical panel groups, who are sequestered the entire time onsite, to larger numbers of panelists who can make their judgments offsite with little impact on judged samples of qualified performance. Standard setting designs having panelists train together and then allowing those to provide judgments yields equivalent ratings and, ultimately, similar cut scores.

  19. Intercomparison of the medium energy primary standards for X-ray exposure of NPL and ENEA, Italy

    International Nuclear Information System (INIS)

    Moretti, C.J.; Heaton, J.A.; Laitano, R.F.; Toni, M.P.

    1991-04-01

    An intercomparison between the primary standards of exposure for medium energy X-rays held by the National Physical Laboratory (NPL) and ENEA in Italy is described. The intercomparison, using four different transfer chambers, took place at NPL in December 1989 and at ENEA during March 1990. Measurements were made at four therapy-level qualities, with half value layers of 0.15, 0.5, 1.0 and 2.5 mm Cu (nominal generating voltages of 100, 135, 180 and 250 kV respectively). At the 2.5 mm Cu HVL quality the primary standards were found to agree to within about 0.8%; for the other three qualities the chambers differed by no more than 0.3%. (author)

  20. Responses to Human Bioeffluents at Levels Recommended by Ventilation Standards

    DEFF Research Database (Denmark)

    Zhang, Xiaojing; Wargocki, Pawel; Lian, Zhiwei

    2017-01-01

    The purpose of this study was to examine whether exposure to human bioeffluents, at the levels recommended by the current ventilation standards, would cause any effects on humans. Ten subjects were exposed in a low-emission stainless-steel climate chamber for 4.25 hours. The outdoor air supply rate...... was set to 33 or 4 l/s per person, creating two levels of bioeffluents with carbon dioxide (CO2) at 500 or 1600 ppm. Subjective ratings were collected, cognitive performance was examined and physiological responses were monitored. The results show that exposures to human bioeffluents at ventilation rate...

  1. [Development of a computerized system using standard nursing language for creation of a nursing minimum data set].

    Science.gov (United States)

    D'Agostino, Fabio; Vellone, Ercole; Tontini, Francesco; Zega, Maurizio; Alvaro, Rosaria

    2012-01-01

    The aim of a nursing data set is to provide useful information for assessing the level of care and the state of health of the population. Currently, both in Italy and in other countries, this data is incomplete due to the lack of a structured nursing documentation , making it indispensible to develop a Nursing Minimum Data Set (NMDS) using standard nursing language to evaluate care, costs and health requirements. The aim of the project described , is to create a computer system using standard nursing terms with a dedicated software which will aid the decision-making process and provide the relative documentation. This will make it possible to monitor nursing activity and costs and their impact on patients' health : adequate training and involvement of nursing staff will play a fundamental role.

  2. Sulfonylurea herbicides – methodological challenges in setting aquatic limit values

    DEFF Research Database (Denmark)

    Rosenkrantz, Rikke Tjørnhøj; Baun, Anders; Kusk, Kresten Ole

    according to the EU Water Framework Directive, the resulting Water Quality Standards (WQSs) are below the analytical quantification limit, making it difficult to verify compliance with the limit values. However, several methodological concerns may be raised in relation to the very low effect concentrations...... and rimsulfuron. The following parameters were varied during testing: pH, exposure duration, temperature and light/dark cycle. Preliminary results show that a decrease in pH causes an increase in toxicity for all compounds. Exposure to a high concentration for 24 hours caused a reduction in growth rate, from...... for setting limit values for SUs or if more detailed information should be gained by taking methodological considerations into account....

  3. Critical evaluation of German regulatory specifications for calculating radiological exposure

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, Claudia; Walther, Clemens [Hannover Univ. (Germany). Inst. of Radioecology; Smeddinck, Ulrich [Technische Univ. Braunschweig (Germany). Inst. of Law

    2015-07-01

    The assessment of radiological exposure of the public is an issue at the interface between scientific findings, juridical standard setting and political decision. The present work revisits the German regulatory specifications for calculating radiological exposure, like the already existing calculation model General Administrative Provision (AVV) for planning and monitoring nuclear facilities. We address the calculation models for the recent risk assessment regarding the final disposal of radioactive waste in Germany. To do so, a two-pronged approach is pursued. One part deals with radiological examinations of the groundwater-soil-transfer path of radionuclides into the biosphere. Processes at the so-called geosphere-biosphere-interface are examined, especially migration of I-129 in the unsaturated zone. This is necessary, since the German General Administrative Provision does not consider radionuclide transport via groundwater from an underground disposal facility yet. Especially data with regard to processes in the vadose zone are scarce. Therefore, using I-125 as a tracer, immobilization and mobilization of iodine is investigated in two reference soils from the German Federal Environment Agency. The second part of this study examines how scientific findings but also measures and activities of stakeholders and concerned parties influence juridical standard setting, which is necessary for risk management. Risk assessment, which is a scientific task, includes identification and investigation of relevant sources of radiation, possible pathways to humans, and maximum extent and duration of exposure based on dose-response functions. Risk characterization identifies probability and severity of health effects. These findings have to be communicated to authorities, who have to deal with the risk management. Risk management includes, for instance, taking into account acceptability of the risk, actions to reduce, mitigate, substitute or monitor the hazard, the setting of

  4. Clarifying and simplifying the management of environmental exposures under different exposure situations

    International Nuclear Information System (INIS)

    Pentreath, R.J.

    2012-01-01

    The International Commission on Radiological Protection recognises three different exposure situations: planned, existing, and emergency. In all three situations, the release of radionuclides into the natural environment leads to exposures of non-human species, as well as having the potential for exposures of the general public. Each release may therefore need separate evaluations of these two consequences in order to clarify the relevant objectives of protection, their compliance with various legal requirements, and how these objectives can be achieved. However, the need to meet more than one objective should not necessarily lead to a more complicated regulatory system. Indeed, with regard to low-level routine discharges from most nuclear plants, there would appear to be scope for simplifying the entire system, to protect both humans and biota, by using discharge consent and specified radionuclide environmental quality standards for water, soil, and air in a manner similar to that used to regulate other major, non-nuclear industries. In contrast, different objectives for humans and the environment need to be set and evaluated independently for existing exposure situations. For emergency situations, the separate consequences of different management options for humans and the environment should be made clear. Should an emergency occur, it is important to have meaningful environmental criteria in order to communicate clearly with the public at large as events unfold.

  5. A MEPS is a MEPS is a MEPS. Comparing Ecodesign and Top Runner schemes for setting product efficiency standards

    Energy Technology Data Exchange (ETDEWEB)

    Siderius, P.J.S. [NL Agency, Croeselaan 15, P.O. Box 8242, 3503 RE Utrecht (Netherlands); Nakagami, H. [Jyukankyo Research Institute, 3-29, Kioi-cho, Chiyoda-ku Tokyo, 102-0094 (Japan)

    2013-02-15

    Both Top Runner in Japan and Ecodesign in the European Union are schemes to set requirements on the energy efficiency (minimum efficiency performance standards, MEPS) of a variety of products. This article provides an overview of the main characteristics and results of both schemes and gives recommendations for improving them. Both schemes contribute significantly to the energy efficiency targets set by the European Commission and the Japanese government. Although it is difficult to compare the absolute levels of the requirements, comparison of the relative improvements and of the savings on household electricity consumption (11 % in Japan, 16 % in the EU) suggest they are in the same range. Furthermore, the time needed to set or review requirements is in both schemes considerable (between 5 and 6 years on average) and the manageability increasingly will become a challenge. The appeal of the Top Runner approach is that the most efficient product (Top Runner) sets the standard for all products at the next target year. Although the Ecodesign scheme includes the elements for a Top Runner approach, it could exploit this principle more explicitly. On the other hand, the Top Runner scheme could benefit by using a real minimum efficiency performance standard instead of a fleet average. This would make the monitoring and enforcement more simple and transparent, and would open the scheme for products where the market situation is less clear.

  6. Comparison of a suspended radiation protection system versus standard lead apron for radiation exposure of a simulated interventionalist.

    Science.gov (United States)

    Marichal, Daniel A; Anwar, Temoor; Kirsch, David; Clements, Jessica; Carlson, Luke; Savage, Clare; Rees, Chet R

    2011-04-01

    To evaluate the radiation protective characteristics of a system designed to enhance operator protection while eliminating weight to the body and allowing freedom of motion. Radiation doses to a mock interventionalist were measured with calibrated dosimeters in a clinical interventional suite. A standard lead apron (SLA; Pb equivalent, 0.5 mm) was compared with a suspended radiation protection system (ZeroGravity; Zgrav) that shields from the top of the head to the calves (except the right arm and left forearm) with a complex overhead motion system that eliminates weight on the operator and allows freedom of motion. Zgrav included a suspended lead apron with increased lead equivalency, greater length, proximal left arm and shoulder coverage, and a wraparound face shield of 0.5 mm Pb equivalency. A 26-cm-thick Lucite stack (ie, mock patient) created scatter during 10 controlled angiography sequences of 120 exposures each. Parameters included a field of view of 40 cm, table height of 94 cm, 124 cm from the tube to image intensifier, 50 cm from the image center to operator, 66 kVp, and 466-470 mA. Under identical conditions, average doses (SLA vs Zgrav) were 264 versus 3.4 (ratio, 78) to left axilla (P < .001), 456 versus 10.2 (ratio, 45) to left eye (P < .001), 379.4 versus 6.6 (ratio, 57) to right eye (P < .005), and 18.8 versus 1.2 (ratio, 16) to gonad (P < .001). Relative to a conventional lead apron, the Zgrav system provided a 16-78-fold decrease in radiation exposure for a mock interventionalist in a simulated clinical setting. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.

  7. Task-based dermal exposure models for regulatory risk assessment.

    Science.gov (United States)

    Warren, Nicholas D; Marquart, Hans; Christopher, Yvette; Laitinen, Juha; VAN Hemmen, Joop J

    2006-07-01

    The regulatory risk assessment of chemicals requires the estimation of occupational dermal exposure. Until recently, the models used were either based on limited data or were specific to a particular class of chemical or application. The EU project RISKOFDERM has gathered a considerable number of new measurements of dermal exposure together with detailed contextual information. This article describes the development of a set of generic task-based models capable of predicting potential dermal exposure to both solids and liquids in a wide range of situations. To facilitate modelling of the wide variety of dermal exposure situations six separate models were made for groupings of exposure scenarios called Dermal Exposure Operation units (DEO units). These task-based groupings cluster exposure scenarios with regard to the expected routes of dermal exposure and the expected influence of exposure determinants. Within these groupings linear mixed effect models were used to estimate the influence of various exposure determinants and to estimate components of variance. The models predict median potential dermal exposure rates for the hands and the rest of the body from the values of relevant exposure determinants. These rates are expressed as mg or microl product per minute. Using these median potential dermal exposure rates and an accompanying geometric standard deviation allows a range of exposure percentiles to be calculated.

  8. Exposure of nitrous oxide to X-rays

    International Nuclear Information System (INIS)

    Yanagida, H.

    1980-01-01

    A study was performed to determine how much NO and NO 2 is produced when nitrous oxide is exposed to X-radiation. Polyethylene bottles filled with either nitrous oxide alone or with nitrous oxide and 30% oxygen were placed 30 cm from the X-ray tube at a standard X-ray beam setting for chest fluoroscopy for 0 to 5 minutes. In the bottles filled with nitrous oxide alone, the production of NO was not affected by the duration of X-ray exposure, but the longer duration of X-ray exposure produced a larger amount of NO 2 . In the bottles filled with nitrous oxide and 30% oxygen, the longer duration of X-ray exposure produced larger amounts of both NO and NO 2 . These findings confirmed a previous investigation in which nitrous oxide was not inert under X-ray exposure. As the presence of oxygen plays an important role in the oxidation of nitrous oxide under X-ray exposure, this study suggests another potentially hazardous interaction that may occur secondary to the administration of an anaesthetic in the presence of X-irradiation as in pulmonary angiography, cardiac catheterisation, and fluoroscopic bronchoscopy or biopsy. (author)

  9. The calculation of maximum permissible exposure levels for laser radiation

    International Nuclear Information System (INIS)

    Tozer, B.A.

    1979-01-01

    The maximum permissible exposure data of the revised standard BS 4803 are presented as a set of decision charts which ensure that the user automatically takes into account such details as pulse length and pulse pattern, limiting angular subtense, combinations of multiple wavelength and/or multiple pulse lengths, etc. The two decision charts given are for the calculation of radiation hazards to skin and eye respectively. (author)

  10. The ionising radiation (medical exposure) regulations - IR (ME) R, Malta

    International Nuclear Information System (INIS)

    Desai, R.; Brejza, P.; Cremona, J.

    2004-01-01

    framework of procedures for medical exposures. Asole practitioner is required to establish and follow his own procedures. The employer's guidelines must cover the matters set out in regulations 9.1.1 to 9.1.12. It also requires the employer to establish written protocols for standard radiological practices, recommendations concerning referral criteria, quality assurance programmes for standard operating procedures, diagnostic reference levels, appropriate guidance and dose constrains for helpers and medical research programmes. It also requires investigations of incidents suspecting that a patient may have received a radiation dose much greater than intended. 10. Regulation 10 requires the practitioner and operator to comply with the employer's procedures. 11. Regulation 11 provides list of duties of practitioner, referrer and operator. 12. Regulation 12 provides optimisation of procedures so as to ensure that exposure is kept as low as reasonably practicable. The practitioner and the operator are responsible for the optimisation of medical exposures as specified in this regulation. This regulation provides that special attention be given to exposure in (i) medico-legal procedures (ii) health screening or voluntary participation in research where no direct medical benefit is expected from the exposure or where exposure involves high doses, (iii) pregnant or potentially pregnant women (iv) breast-feeding females (v) children. This regulation also provides that certain written instruction and information be given where radioactive medicinal products are administered. 13. Regulation 13 provides for medical physics experts to be consulted where appropriate. 14. Regulation 14 prohibits a practitioner or operator from carrying out a medical procedure without having been adequately trained and requires the employer to keep a record of training qualifications of all practitioners and operators engaged by him. 15. Regulation 15 requires the employer to maintain an inventory of

  11. Some non-scientific influences on radiation protection standards and practice

    International Nuclear Information System (INIS)

    Taylor, L.S.

    1980-01-01

    In this introductory lecture to the 5th International Congress of the IRPA, the problem of setting radiation protection standards and practice is broadly reviewed under the following headings:- 1) Biological effects of radiation, 2) Philosophy, 3) The Media, 4) Morality, (with particular reference to the problem of different classes of exposure) 5) Laws and Regulations (with particular reference to the U.S.) 6) Economics, 7) Education, 8) Credibility of scientists. It is suggested that because of their basic training in a sense of objectivity, a good argument can be made that scientists are as devoid of special interest as any other group. An argument is made that the problem of setting standards for protection can be reduced to a blending of two theories, a) that we are dealing with a single linear, no-threshold dose-effect relationship and b) the toxicological view that concentrations of a toxic substance should be set somewhat below that at which any effect could be found. (U.K.)

  12. Heart rate variability and the relationship between trauma exposure age, and psychopathology in a post-conflict setting.

    Science.gov (United States)

    Liddell, Belinda J; Kemp, Andrew H; Steel, Zachary; Nickerson, Angela; Bryant, Richard A; Tam, Natalino; Tay, Alvin Kuowei; Silove, Derrick

    2016-05-10

    Cumulative exposure to potentially traumatic events (PTEs) increases risk for mental distress in conflict-affected settings, but the psychophysiological mechanisms that mediate this dose-response relationship are unknown. We investigated diminished heart rate variability (HRV) - an index of vagus nerve function and a robust predictor of emotion regulation capacity - as a vulnerability marker that potentially mediates the association between PTE exposure, age and symptoms of posttraumatic stress disorder (PTSD), psychological distress and aggressive behavior, in a community sample from Timor-Leste - a post-conflict country with a history of mass violence. Resting state heart rate data was recorded from 45 cases of PTSD, depression and intermittent explosive disorder (IED); and 29 non-case controls. Resting HRV was significantly reduced in the combined case group compared with non-cases (p = .021; Cohen's d = 0.5). A significant mediation effect was also observed, whereby a sequence of increased age, reduced HRV and elevated PTSD symptoms mediated the association between PTE exposure and distress (B = .06, SE = .05, 95% CI = [.00-.217]) and aggression (B = .02, SE = .02, 95% CI = [.0003-.069])). The findings demonstrate an association between diminished resting HRV and psychopathology. Moreover, age-related HRV reductions emerged as a potential psychophysiological mechanism that underlies enhanced vulnerability to distress and aggression following cumulative PTE exposure.

  13. Multiple Forms and Settings of Exposure to Violence and Values: Unique and Interactive Relationships With Antisocial Behavior in Adolescence.

    Science.gov (United States)

    Bacchini, Dario; Affuso, Gaetana; Aquilar, Serena

    2015-10-01

    The general purpose of this study was to investigate the relationships between multiple forms and settings of exposure to violence (ETV) as well as personal values and antisocial behavior (ASB) in adolescence. The association of ETV as witness or victim in different contexts (family, school, or neighborhood) and the association of the selected values of power, universalism, and conformity with ASB were analyzed. In addition, the role of ETV in moderating the relationship between values and ASB was tested. A total of 369 adolescents participated in the study. Hierarchical multiple regression analysis was performed. Results revealed that ASB was independently affected by exposure to family violence as a victim, exposure to school violence as a witness, exposure to neighborhood violence as a witness, and by all three selected values. The associations of ASB with universalism and conformity were negative. Conversely, the association of ASB with power was positive. One interaction had statistically significant effects. Results revealed that exposure to school violence as a witness moderates the relationship between universalism and ASB. The results highlight a high percentage of explained variance by ETV and values on ASB and suggest the importance of adopting a socio-ecological framework in interpreting adolescent behavior. © The Author(s) 2014.

  14. Implementing standardized, inter-unit communication in an international setting: handoff of patients from emergency medicine to internal medicine.

    Science.gov (United States)

    Balhara, Kamna S; Peterson, Susan M; Elabd, Mohamed Moheb; Regan, Linda; Anton, Xavier; Al-Natour, Basil Ali; Hsieh, Yu-Hsiang; Scheulen, James; Stewart de Ramirez, Sarah A

    2018-04-01

    Standardized handoffs may reduce communication errors, but research on handoff in community and international settings is lacking. Our study at a community hospital in the United Arab Emirates characterizes existing handoff practices for admitted patients from emergency medicine (EM) to internal medicine (IM), develops a standardized handoff tool, and assesses its impact on communication and physician perceptions. EM physicians completed a survey regarding handoff practices and expectations. Trained observers utilized a checklist based on the Systems Engineering Initiative for Patient Safety model to observe 40 handoffs. EM and IM physicians collaboratively developed a written tool encouraging bedside handoff of admitted patients. After the intervention, surveys of EM physicians and 40 observations were subsequently repeated. 77.5% of initial observed handoffs occurred face-to-face, with 42.5% at bedside, and in four different languages. Most survey respondents considered face-to-face handoff ideal. Respondents noted 9-13 patients suffering harm due to handoff in the prior month. After handoff tool implementation, 97.5% of observed handoffs occurred face-to-face (versus 77.5%, p = 0.014), with 82.5% at bedside (versus 42.5%, p face-to-face and bedside handoff, positively impacted workflow, and increased perceptions of safety by EM physicians in an international, non-academic setting. Our three-step approach can be applied towards developing standardized, context-specific inter-specialty handoff in a variety of settings.

  15. Exposure-Based Screening and Priority-Setting (WC10)

    Science.gov (United States)

    The U.S. National Academy of Sciences report “Using 21st Century Science to Improve Risk-Related Evaluations” recognized that high-throughput screening (HTS) and exposure prediction tools are necessary to prioritize thousands of chemicals with the potential to pose human health r...

  16. Setting the standard, implementation and auditing within haemodialysis.

    Science.gov (United States)

    Jones, J

    1997-01-01

    With an ever increasing awareness of the need to deliver a quality of care that is measurable in Nursing, the concept of Standards provides an ideal tool (1). Standards operate outside the boundaries of policies and procedures to provide an audit tool of authenticity and flexibility. Within our five Renal Units, while we felt confident that we were delivering an excellent standard of care to our patients and continually trying to improve upon it, what we really needed was a method of measuring this current level of care and highlighting key areas where we could offer improvement.

  17. Setting and Reviewing Standards to Control Lead (Pb) Pollution

    Science.gov (United States)

    Lead (Pb) standards are part of the National Ambient Air Quality Standards (NAAQS), which limit air pollution to protect health and the environment. Standards are periodically reviewed and updated, and air quality across the U.S. is measured against them.

  18. Setting ambient air quality standards for particulate matter

    International Nuclear Information System (INIS)

    McClellan, Roger O.

    2002-01-01

    Ambient air particulate matter (PM), unspecified as to chemical composition, is of concern because of its health effects. Air quality standards for PM have been established in many countries. The earliest standards were based on threshold models and use of a margin of safety. Initially, standards were based on the mass of total suspended material. In the 1980s a shift to a size-specific standard, PM 10 , began. PM 10 is the fraction of PM captured with 50% efficiency at 10 μm and greater efficiency at smaller sizes. In the late 1990s, standards were proposed for PM 2.5 , which is captured with 50% efficiency at 2.5 μm. The standards for PM are based almost exclusively on human epidemiological data, with laboratory animal and in vitro data used in a supporting role. During the 1990s, new statistical tools began to be used and demonstrated an association between increased PM and an increase in cardiorespiratory morbidity and mortality. The analyses are complicated by the effects of other pollutants such as ozone. Effects have been observed down to 10-20 μg of PM 10 per cubic meter, levels equal to or below background in many parts of the world. In many studies there has been no evidence of a threshold. In the absence of a threshold, a critical issue becomes how to determine how low is low enough? This paper reviews the current literature on PM health effects and suggests research avenues that may yield data which, combined with public policy considerations, may be able to address the issue of 'how low is low enough?'

  19. Developing evidence-based prescriptive ventilation rate standards for commercial buildings in California: a proposed framework

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, Mark J.; Fisk, William J.

    2014-02-01

    Background - The goal of this project, with a focus on commercial buildings in California, was to develop a new framework for evidence-based minimum ventilation rate (MVR) standards that protect occupants in buildings while also considering energy use and cost. This was motivated by research findings suggesting that current prescriptive MVRs in commercial buildings do not provide occupants with fully safe and satisfactory indoor environments. Methods - The project began with a broad review in several areas ? the diverse strategies now used for standards or guidelines for MVRs or for environmental contaminant exposures, current knowledge about adverse human effects associated with VRs, and current knowledge about contaminants in commercial buildings, including their their presence, their adverse human effects, and their relationships with VRs. Based on a synthesis of the reviewed information, new principles and approaches are proposed for setting evidence-based VRs standards for commercial buildings, considering a range of human effects including health, performance, and acceptability of air. Results ? A review and evaluation is first presented of current approaches to setting prescriptive building ventilation standards and setting acceptable limits for human contaminant exposures in outdoor air and occupational settings. Recent research on approaches to setting acceptable levels of environmental exposures in evidence-based MVR standards is also described. From a synthesis and critique of these materials, a set of principles for setting MVRs is presented, along with an example approach based on these principles. The approach combines two sequential strategies. In a first step, an acceptable threshold is set for each adverse outcome that has a demonstrated relationship to VRs, as an increase from a (low) outcome level at a high reference ventilation rate (RVR, the VR needed to attain the best achievable levels of the adverse outcome); MVRs required to meet each

  20. Will the changes proposed to the conceptual framework’s definitions and recognition criteria provide a better basis for the IASB standard setting?

    NARCIS (Netherlands)

    Brouwer, A.; Hoogendoorn, M.; Naarding, E.

    2015-01-01

    In this paper we evaluate the International Accounting Standards Board’s (IASB) efforts, in a discussion paper (DP) of 2013, to develop a new conceptual framework (CF) in the light of its stated ambition to establish a robust and consistent basis for future standard setting, thereby guiding standard

  1. The Cultural Influence in Accounting Standard Setting: A Comparative Analysis of the United States, Canada, and England.

    Science.gov (United States)

    Bloom, Robert; And Others

    A study of the processes for establishing the principles and policies of measurement and disclosure in preparing financial reports examines differences in these processes in the United States, Canada, and England. Information was drawn from international accounting literature on standard setting. The differences and similarities in the…

  2. Analysis of Item-Level Bias in the Bayley-III Language Subscales: The Validity and Utility of Standardized Language Assessment in a Multilingual Setting.

    Science.gov (United States)

    Goh, Shaun K Y; Tham, Elaine K H; Magiati, Iliana; Sim, Litwee; Sanmugam, Shamini; Qiu, Anqi; Daniel, Mary L; Broekman, Birit F P; Rifkin-Graboi, Anne

    2017-09-18

    The purpose of this study was to improve standardized language assessments among bilingual toddlers by investigating and removing the effects of bias due to unfamiliarity with cultural norms or a distributed language system. The Expressive and Receptive Bayley-III language scales were adapted for use in a multilingual country (Singapore). Differential item functioning (DIF) was applied to data from 459 two-year-olds without atypical language development. This involved investigating if the probability of success on each item varied according to language exposure while holding latent language ability, gender, and socioeconomic status constant. Associations with language, behavioral, and emotional problems were also examined. Five of 16 items showed DIF, 1 of which may be attributed to cultural bias and another to a distributed language system. The remaining 3 items favored toddlers with higher bilingual exposure. Removal of DIF items reduced associations between language scales and emotional and language problems, but improved the validity of the expressive scale from poor to good. Our findings indicate the importance of considering cultural and distributed language bias in standardized language assessments. We discuss possible mechanisms influencing performance on items favoring bilingual exposure, including the potential role of inhibitory processing.

  3. Reduction of Secondhand Smoke Exposure in the Cars of Children With Cancer.

    Science.gov (United States)

    Peck, Kelly R; Tyc, Vida L; Huang, Qinlei; Zhang, Hui

    2015-01-01

    This study examined whether an intervention designed to reduce secondhand smoke exposure (SHSe) among children being treated for cancer had effects in the specific setting of a motor vehicle. The parents or guardians (n = 71) of children being treated for cancer were randomized to either a behavioral secondhand smoke (SHS) reduction program or a standard care control group. Parental reports of SHSe were collected over the course of 12 months. Younger children were exposed at baseline more than their older counterparts. The greatest initial declines in car exposure were observed among children ≤5 years old in the intervention group compared with same-aged peers in the control group. After the 3-month time point, the control group showed greater reductions in car exposure in comparison with the intervention group. Interventions that teach parents strategies to manage their smoking while driving in their personal vehicles may produce even greater reductions in child exposure and should be developed. Based on the age-specific results reported here, future studies should account for effects of child age and use setting-specific measures of SHS. © 2015 by Association of Pediatric Hematology/Oncology Nurses.

  4. Social settings and addiction relapse.

    Science.gov (United States)

    Walton, M A; Reischl, T M; Ramanthan, C S

    1995-01-01

    Despite addiction theorists' acknowledgment of the impact of environmental factors on relapse, researchers have not adequately investigated these influences. Ninety-six substance users provided data regarding their perceived risk for relapse, exposure to substances, and involvement in reinforcing activities. These three setting attributes were assessed in their home, work, and community settings. Reuse was assessed 3 months later. When controlling for confounding variables, aspects of the home settings significantly distinguished abstainers from reusers; perceived risk for relapse was the strongest predictor of reuse. Exposure to substances and involvement in reinforcing activities were not robust reuse indicators. The work and community settings were not significant determinants of reuse. These findings offer some initial support for the utility of examining social settings to better understand addiction relapse and recovery. Identification of setting-based relapse determinants provides concrete targets for relapse prevention interventions.

  5. Workers’ cytokines profiling upon exposure to MWCNT aerosol in occupational settings

    Science.gov (United States)

    Fatkhutdinova, L. M.; Khaliullin, T. O.; Zalyalov, R. R.; Vasilyeva, O. L.; Valeeva, I. Kh; Mustafin, I. G.

    2015-11-01

    Recent studies have found that upon pulmonary exposure to multi-walled carbon nanotubes (MWCNTs) animals develop primarily fibrosis and granulomas in lungs. In vitro and in vivo studies also give reason to assume that local exposure could be related to remote effects, including immune system and the endothelium. To investigate the remote effect hypothesis, we have analyzed blood, nasal lavage and induced sputum samples taken from workers in the frame of the Russian epidemiological study on Carbon Nanotubes Exposure and Risk Assessment (CNT-ERA). In serum and nasal lavage no significant differences between exposure and control groups were observed with a high variability to the cytokines content. In the samples of induced sputum from exposed workers the content of IL-1b, IL-6, IL-8, TNF-a, IL-4, IL-5, IFN-g exceeded the control group values, but after the regression models construction and bootstrap analysis, significant differences were found only for IL-1b. This study could not provide evidences of blood cytokines changes following local cytokine production in airways in workers exposed to MWCNTs. Cytokines variability in serum and nasal lavage may indicate the absence of severe systemic inflammatory response upon the existing occupational exposure to MWCNTs. Other systemic responses (including allergy-like or autoimmune reactions) should be regarded as well.

  6. An expanded calibration study of the explicitly correlated CCSD(T)-F12b method using large basis set standard CCSD(T) atomization energies.

    Science.gov (United States)

    Feller, David; Peterson, Kirk A

    2013-08-28

    The effectiveness of the recently developed, explicitly correlated coupled cluster method CCSD(T)-F12b is examined in terms of its ability to reproduce atomization energies derived from complete basis set extrapolations of standard CCSD(T). Most of the standard method findings were obtained with aug-cc-pV7Z or aug-cc-pV8Z basis sets. For a few homonuclear diatomic molecules it was possible to push the basis set to the aug-cc-pV9Z level. F12b calculations were performed with the cc-pVnZ-F12 (n = D, T, Q) basis set sequence and were also extrapolated to the basis set limit using a Schwenke-style, parameterized formula. A systematic bias was observed in the F12b method with the (VTZ-F12/VQZ-F12) basis set combination. This bias resulted in the underestimation of reference values associated with small molecules (valence correlation energies 0.5 E(h)) and an even larger overestimation of atomization energies for bigger systems. Consequently, caution should be exercised in the use of F12b for high accuracy studies. Root mean square and mean absolute deviation error metrics for this basis set combination were comparable to complete basis set values obtained with standard CCSD(T) and the aug-cc-pVDZ through aug-cc-pVQZ basis set sequence. However, the mean signed deviation was an order of magnitude larger. Problems partially due to basis set superposition error were identified with second row compounds which resulted in a weak performance for the smaller VDZ-F12/VTZ-F12 combination of basis sets.

  7. Comparison of ESD and major organ absorbed doses of 5 year old standard guidekines and clinical exposure conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kang, A Ram; Ahn, Sung Min [Dept. of Radiological Science, The Graduate School, Gachon University, Incheon (Korea, Republic of); Lee, In Ja [Dept. of Radiologic technology, Dongnam health University, Suwon (Korea, Republic of)

    2017-09-15

    Pediatrics are more sensibility to radiation than adults and because they are organs that are not completely grown, they have a life expectancy that can be adversely affected by exposure. Therefore, the management of exposure dose is more important than the case of adult. The purpose of this study was to determine the suitability of the 10 year old phantom for the 5 year old pediatric's recommendation and the incident surface dose, and to measure the organ absorbed dose. This study is compared the organ absorbed dose and the entrance surface dose in the clinical conditions at 5 and 10 years old pediatric. Clinical 5 year old condition was slightly higher than recommendation condition and 10 year old condition was very high. In addition, recommendation condition ESD was found to be 43% higher than the ESD of the 5 year old group and the ESD of the 10 year old group was 126% higher than that of the 5 year old group. The recommended ESD at 5 years old and the ESD according to clinical imaging conditions were 31.6%. There was no significant difference between the 5 year old recommended exposure conditions and the organ absorbed dose due to clinical exposure conditions, but there was a large difference between the Chest and Pelvic. However, it was found that there was a remarkable difference when comparing the organ absorbed dose by 10 year clinical exposure conditions. Therefore, more detailed standard exposure dose for the recommended dose of pediatric should be studied.

  8. Comparison of ESD and major organ absorbed doses of 5 year old standard guidekines and clinical exposure conditions

    International Nuclear Information System (INIS)

    Kang, A Ram; Ahn, Sung Min; Lee, In Ja

    2017-01-01

    Pediatrics are more sensibility to radiation than adults and because they are organs that are not completely grown, they have a life expectancy that can be adversely affected by exposure. Therefore, the management of exposure dose is more important than the case of adult. The purpose of this study was to determine the suitability of the 10 year old phantom for the 5 year old pediatric's recommendation and the incident surface dose, and to measure the organ absorbed dose. This study is compared the organ absorbed dose and the entrance surface dose in the clinical conditions at 5 and 10 years old pediatric. Clinical 5 year old condition was slightly higher than recommendation condition and 10 year old condition was very high. In addition, recommendation condition ESD was found to be 43% higher than the ESD of the 5 year old group and the ESD of the 10 year old group was 126% higher than that of the 5 year old group. The recommended ESD at 5 years old and the ESD according to clinical imaging conditions were 31.6%. There was no significant difference between the 5 year old recommended exposure conditions and the organ absorbed dose due to clinical exposure conditions, but there was a large difference between the Chest and Pelvic. However, it was found that there was a remarkable difference when comparing the organ absorbed dose by 10 year clinical exposure conditions. Therefore, more detailed standard exposure dose for the recommended dose of pediatric should be studied

  9. A new method for setting guidelines to protect human health from agricultural exposure by using chlorpyrifos as an example

    Directory of Open Access Journals (Sweden)

    Dung Tri Phung

    2015-05-01

    Full Text Available Introduction and objectives. Guidelines set by various agencies for the control and management of chlorpyrifos cover a wide range of values reflecting difficulties in the procedures for their development. To overcome these difficulties a new method to set guidelines would be developed. Published data derived from epidemiological investigations on human populations would be used to develop a dose-response relationship for chlorpyrifos allowing the calculation of threshold values which can be used as guidelines. Materials and Method. Data from the scientific literature on human populations were collected to evaluate the adverse response doses for a range of health effects. The Cumulative Frequency Distribution (CFD for the minimum levels of adverse effects measured in terms of the Lifetime Average Daily Dose (LADD[sub]D[/sub] and the Absorbed Daily Dose for neurological (ADD[sub]DN[/sub] and non-neurological effects were used. Results. Linear regression equations were fitted to the CFD plots giving R 2 values of 0.93 and 0.86 indicating a normal distribution of the data. Using these CFD plots, the chronic and acute threshold values were calculated at the 5% cumulative frequency level for chlorpyrifos exposure giving values at 0.5 µg/kg/d and 3 µg/kg/d respectively. Conclusions. Guidelines set using this technique at the values at 0.5 µg/kg/d and 3 µg/kg/d for chronic and acute exposure respectively provide an alternative to the currently used biological endpoint and safety factor method.

  10. A comparison of two standard-setting approaches in high-stakes clinical performance assessment using generalizability theory.

    Science.gov (United States)

    Richter Lagha, Regina A; Boscardin, Christy K; May, Win; Fung, Cha-Chi

    2012-08-01

    Scoring clinical assessments in a reliable and valid manner using criterion-referenced standards remains an important issue and directly affects decisions made regarding examinee proficiency. This generalizability study of students' clinical performance examination (CPX) scores examines the reliability of those scores and of their interpretation, particularly according to a newly introduced, "critical actions" criterion-referenced standard and scoring approach. The authors applied a generalizability framework to the performance scores of 477 third-year students attending three different medical schools in 2008. The norm-referenced standard included all station checklist items. The criterion-referenced standard included only those items deemed critical to patient care by a faculty panel. The authors calculated and compared variance components and generalizability coefficients for each standard across six common stations. Norm-referenced scores had moderate generalizability (ρ = 0.51), whereas criterion-referenced scores showed low dependability (φ = 0.20). The estimated 63% of measurement error associated with the person-by-station interaction suggests case specificity. Increasing the number of stations on the CPX from 6 to 24, an impractical solution both for cost and time, would still yield only moderate dependability (φ = 0.50). Though the performance assessment of complex skills, like clinical competence, seems intrinsically valid, careful consideration of the scoring standard and approach is needed to avoid misinterpretation of proficiency. Further study is needed to determine how best to improve the reliability of criterion-referenced scores, by implementing changes to the examination structure, the process of standard-setting, or both.

  11. Study of federal microwave standards

    Energy Technology Data Exchange (ETDEWEB)

    David, L.

    1980-08-01

    Present and future federal regulatory processes which may impact the permissible levels of microwave radiation emitted by the SPS Microwave Power Transmission (MPTS) were studied. An historical development of US occupational and public microwave standards includes an overview of Western and East European philosophies of environmental protection and neurophysiology which have led to the current widely differing maximum permissible exposure limits to microwaves. The possible convergence of microwave standards is characterized by a lowering of Western exposure levels while Eastern countries consider standard relaxation. A trend toward stricter controls on activities perceived as harmful to public health is under way as is interest in improving the federal regulatory process. Particularly relevant to SPS is the initiation of long-term, low-level microwave exposure programs. Coupled with new developments in instrumentation and dosimetry, the results from chronic exposure program and population exposure studies could be expected within the next five to ten years. Also discussed is the increasing public concern that rf energy is yet another hazardous environmental agent.

  12. Controlling criteria for radiation exposure of astronauts and space workers

    International Nuclear Information System (INIS)

    Katoh, Kazuaki

    1989-01-01

    Space workers likely to suffer from radiation exposure in the outer space are currently limited to the U.S. and Soviet Union, and only a small amount of data and information is available concerning the techniques and criteria for control of radiation exposure in this field. Criteria used in the Soviet Union are described first. The criteria (TRS-75), called the Radiation Safety Criteria for Space Navigation, are tentative ones set up in 1975. They are based on risk assessment. The standard radiation levels are established based on unit flight time: 50rem for 1 month, 80rem for 3 months, 110rem for 6 months and 150rem for 12 months. These are largely different from the emergency exposure limit of 100mSv (10rem) specified in a Japanese law, and the standard annual exposure value of 50mSv (5rem) for workers in nuclear power plants at normal times. For the U.S., J.A. Angelo, Jr., presented a paper titled 'Radiation Protection Issues and Techniques concerning Extended Manned Space Missions' at an IAEA meeting held in 1988. Though the criteria shown in the paper are not formal ones at the national level, similar criteria are expected to be adopted by the nation in the near future. The exposure limits recommended in the paper include a depth dose of 1-4Sv for the whole life span of a worker. (Nogami, K.)

  13. Exposure Factors Resources: Contrasting EPA’s Exposure Factors Handbook with International Sources (Journal Article)

    Science.gov (United States)

    Efforts to compile and standardize exposure human factors have resulted in the development of a variety of resources available to the scientific community. For example, the U.S. EPA developed the Exposure Factors Handbook and Child-specific Exposure Factors Handbook to promote c...

  14. Occupational hazard: radiation exposure for the urologist: developing a reference standard

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, Seth A.; Rangarajan, Sriram S.; Chen, Tony; Palazzi, Kerrin L.; Langford, J. Scott; Sur, Roger L., E-mail: rlsur@ucsd.edu [Department of Surgery and Division of Urology, U C San Diego Health Science System, San Diego, CA (United States)

    2013-03-15

    Introduction: to date, there is a paucity of literature offering practicing urologists a reference for the amount of radiation exposure received while surgically managing urolithiasis. This study examines the cumulative radiation exposure of an urologist over 9 months. Materials and methods: We present a case series of fluoroscopic exposures of an experienced stone surgeon operating at an academic comprehensive stone center between April and December 2011. Radiation exposure measurements were determined by a thermoluminescent dosimeter worn on the outside of the surgeon's thyroid shield. Estimations of radiation exposure (mrem) per month were charted with fluoroscopy times, using scatter plots to estimate Spearman's rank correlation coefficients. Results: the total 9-month radiation exposure was 87 mrems for deep dose equivalent (DDE), 293 mrem for lens dose equivalent (LDE), and 282 mrem for shallow dose equivalent (SDE). Total fluoroscopy time was 252.44 minutes for 64 ureteroscopies (URSs), 29 percutaneous nephrolithtomies (PNLs), 20 cystoscopies with ureteral stent placements, 9 shock wave ithotripsies (SWLs), 9 retrograde pyelograms (RPGs), 2 endoureterotomies, and 1 ureteral balloon dilation. Spearman's rank correlation coefficients examining the association between fluoroscopy time and radiation exposure were not significant for DDE (p = 0.6, Spearman's rho = 0.2), LDE (p = 0.6, Spearman's rho = 0.2), or SDE (p = 0.6, Spearman's rho = 0.2). Conclusions: Over a 9-month period, total radiation exposures were well below annual accepted limits (DDE 5000 mrem, LDE 15,000 mrem and SDE 50,000 mrem). Although fluoroscopy time did not correlate with radiation exposure, future prospective studies can account for co-variates such as patient obesity and urologist distance from radiation source. (author)

  15. Mere Exposure and Racial Prejudice: Exposure to Other-Race Faces Increases Liking for Strangers of That Race.

    Science.gov (United States)

    Zebrowitz, Leslie A; White, Benjamin; Wieneke, Kristin

    2008-01-01

    White participants were exposed to other-race or own-race faces to test the generalized mere exposure hypothesis in the domain of face perception, namely that exposure to a set of faces yields increased liking for similar faces that have never been seen. In Experiment 1, rapid supraliminal exposures to Asian faces increased White participants' subsequent liking for a different set of Asian faces. In Experiment 2, subliminal exposures to Black faces increased White participants' subsequent liking for a different set of Black faces. The findings are consistent with prominent explanations for mere exposure effects as well as with the familiar face overgeneralization hypothesis that prejudice derives in part from negative reactions to faces that deviate from the familiar own-race prototype.

  16. Occupational radiation exposure in international recommendations on radiation protection: Basic standards under review

    International Nuclear Information System (INIS)

    Kraus, W.

    1996-01-01

    The ICRP publication 60 contains a number of new recommendations on the radiological protection of occupationally exposed persons. The recommendations have been incorporated to a very large extent in the BSS, the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources, a publication elaborated by the IAEA in cooperation with many other international organisations, and in the Euratom Basic Safety Standards (EUR) to be published soon. However, there exist some considerable discrepancies in some aspects of the three publications. The ICRP committee has set up a task group for defining four general principles of occupational radiation protection, and a safety guide is in preparation under the responsibility of the IAEA. ''StrahlenschutzPraxis'' will deal with this subject in greater detail after publication of these two important international publications. The article in hand discusses some essential aspects of the recommendations published so far. (orig.) [de

  17. Health and safety impacts of nuclear, geothermal, and fossil-fuel electric generation in California. Volume 2. Radiological health and related standards for nuclear power plants

    International Nuclear Information System (INIS)

    Nero, A.V.; Wong, Y.C.

    1977-01-01

    This report summarizes the status and basis of radiation protection standards, with a view to identifying how they particularly apply to nuclear power plants. The national and international organizations involved in the setting of standards are discussed, paying explicit attention to their jurisdictions and to the considerations they use in setting standards. The routine and accidental radioactive emissions from nuclear power plants are characterized, and the effect of these emissions on ambient radiation levels is discussed. The state of information on the relationship between radiation exposures and health effects is summarized

  18. Changes in patient exposure doses from diagnostic radiological procedures in Japan, 1974-2007

    International Nuclear Information System (INIS)

    Suzuki, Shoichi; Ito, Yusuke; Asada, Yasuki; Hattori, S.; Kamei, S.; Koga, Sukehiko

    2008-01-01

    We have investigated changes in exposure dose in Japan in terms of the same items since 1974. An assessment was made of changes in exposure dose during a period of 33 years. Nationwide investigation was conducted six times from 1974 to 2007 with regard to 14 target areas (21 kinds of projections). The investigations we examined is as follows: tube voltage (kV), tube current (mA), exposure time (sec), focus surface distance, thickness of total filtration and type of generator system for diagnostic radiography for a typical patient. Entrance surface doses were evaluated in terms of the respective exposure conditions based on basic experiment. The results showed that the exposure doses decreased to less than 50% during a 15-year period till 1994, with the exposure doses in 1974 assumed to be 100%. The exposure doses in 2007 were equivalent to, or increased over the exposure doses in 1994 at some areas. A comparison with the international basic safety standard for protection against ionizing radiation set up by the IAEA, that is, the so-called guidance level, indicated that the exposure doses in 2007 were less than the standard in all areas. The comparison with past investigations also demonstrated that F/S system using film-intensifying screen has been increasingly replaced with computed radiography (CR) system using imaging plates (IP) and flat panel digital radiography (FPD) system. In the investigation in 2007, an attempt was made of a comparison between exposure dose by the digital radiography system and that by the F/S system as well. It was clarified that there was no large difference in the exposure dose between those systems. (author)

  19. Nitrous oxide pollution during x-ray exposure

    International Nuclear Information System (INIS)

    Yanagida, Hisashi; Nakajima, Michiaki.

    1980-01-01

    X-radiation has been shown to produce NO and NO 2 in the presence of nitrous oxide. The purpose of the present study was to confirm how much NO and NO 2 was produced when constant amount of nitrous oxide was exposed by constant X-radiation. Twenty polyethylene bottles (capacity 10 litres) were filled with nitrous oxide alone. Another 20 bottles were filled with nitrous oxide and 30% oxygen. Each bottle was placed at a distance of 30 cm from X-ray tube and they were directly in the line of the X-ray beam at a setting of 90 KV at 0.5 mA, a standard setting for chest fluoroscopy. The range of duration of X-ray exposure was from 0 (control), to 2, 3, and 5 minutes in 5 bottles each, respectively. A colorimetric recording method (Saltzman) and a chemiluminescent monitor were used for measurement of NO and NO 2 . In the bottles filled with nitrous oxide alone, the production of NO was not affected by the duration of X-ray exposure, but the longer duration of X-ray exposure produced a larger amount of NO 2 . In the bottles filled with nitrous oxide and 30% oxygen, the longer duration of X-ray exposure produced larger amounts of both NO and NO 2 . These findings confirmed a previous investigation in which nitrous oxide was not inert under X-ray exposure. As the presence of oxygen plays an important role in the oxidation of nitrous oxide under X-ray, this study suggests another potentially hazardous interaction that may occur secondary to the administration of anesthetic in the presence of X-irradiation such as pulmonary angiography, cardiac catheterization, and fluoroscopic bronchoscopy or biopsy under general anesthesia. (author)

  20. Limit values for exposure to physical agents

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    The limit values for exposure to thermal environments adopted by the French AFNOR and by the ISO Working Group (AFNOR Standard X 35-201 and ISO Standard 7243, and AFNOR Standard X 35-204). The limit values for exposure to other physical agents established by the American ACGIH for 1982. The following agents are covered: - laser radiation (ocular and skin exposure); - ultraviolet radiation; - visible and near-infrared radiation (retinal thermal and photochemical injury); - airborne and upper sonic and ultrasonic acoustic radiation; - radiofrequency radiation [fr

  1. Standardizing measurement, sampling and reporting for public exposure assessments

    Energy Technology Data Exchange (ETDEWEB)

    Rochedo, Elaine R.R. [Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear, Av. Salvador Allende s/No. CEP 22780-160 Rio de Janeiro, RJ (Brazil)], E-mail: elaine@ird.gov.br

    2008-11-15

    UNSCEAR assesses worldwide public exposure from natural and man-made sources of ionizing radiation based on information submitted to UNSCEAR by United Nations Member States and from peer reviewed scientific literature. These assessments are used as a basis for radiation protection programs of international and national regulatory and research organizations. Although UNSCEAR describes its assessment methodologies, the data are based on various monitoring approaches. In order to reduce uncertainties and improve confidence in public exposure assessments, it would be necessary to harmonize the methodologies used for sampling, measuring and reporting of environmental results.

  2. Implementing standard setting into the Conjoint MAFP/FRACGP Part 1 examination – Process and issues

    Directory of Open Access Journals (Sweden)

    Chan Sook-Ching

    2016-02-01

    Full Text Available The College of General Practitioners of Malaysia and the Royal Australian College of General Practitioners held the first Conjoint Member of the College of General Practitioners (MCGP/Fellow of Royal Australian College of General Practitioners (FRACGP examination in 1982, later renamed the Conjoint MAFP/FRACGP examinations. The examination assesses competency for safe independent general practice and as family medicine specialists in Malaysia. Therefore, a defensible standard set pass mark is imperative to separate the competent from the incompetent.

  3. Virtual reality exposure therapy

    OpenAIRE

    Rothbaum, BO; Hodges, L; Kooper, R

    1997-01-01

    It has been proposed that virtual reality (VR) exposure may be an alternative to standard in vivo exposure. Virtual reality integrates real-time computer graphics, body tracking devices, visual displays, and other sensory input devices to immerse a participant in a computer- generated virtual environment. Virtual reality exposure is potentially an efficient and cost-effective treatment of anxiety disorders. VR exposure therapy reduced the fear of heights in the first control...

  4. The regulatory framework of accounting and accounting standard-setting bodies in the European Union member states

    OpenAIRE

    Mamić-Sačer, Ivana

    2015-01-01

    One of the principal features of accounting in the 21st century is harmonisation and stanardisation. Regulation of the European Parliament and European Council No. 1606/2002 harmonizes financial reporting for certain companies in the EU. However, national accounting principles are of great importance for financial reporting. The main purpose of this research was to investigate the application of generally accepted accounting principles, the regulatory accounting framework and the standard-set...

  5. Dietary exposure to aluminium in the popular Chinese fried bread youtiao.

    Science.gov (United States)

    Li, Ge; Zhao, Xue; Wu, Shimin; Hua, Hongying; Wang, Qiang; Zhang, Zhiheng

    2017-06-01

    Youtiao is a typical, traditional and widely consumed fried food in China. Fermentation of youtiao involves the use of aluminium potassium sulphate (alum). There are health concerns related to the levels of aluminium in food; therefore, we aimed to determine the aluminium concentrations of youtiao from various locations, and to estimate the dietary exposure by different age groups in southern and northern China. The aluminium content of youtiao samples varied considerably (range = 4.46-852.69 mg kg -1 ). Both the mean and median aluminium contents of youtiao exceeded 100 mg kg -1 , which is the China National Standard (GB) 2760-2014 National Food Safety for Standards for food additives. However, the median and 97.5th percentile of weekly dietary exposure to aluminium from youtiao, estimated using Monte Carlo simulation, did not exceed the provisional tolerable weekly intake (PTWI) set by the joint FAO/WHO Expert Committee on Food Additives (JECFA) for children, adolescents, adults and seniors. The weekly dietary exposure to aluminium would exceed the PTWI if children, adolescents, adults and seniors consumed 134.47, 260.98, 327.10 or 320.41 g of youtiao per week, respectively.

  6. Mortality Associated With Emergency Department Boarding Exposure: Are There Differences Between Patients Admitted to ICU and Non-ICU Settings?

    Science.gov (United States)

    Reznek, Martin A; Upatising, Benjavan; Kennedy, Samantha J; Durham, Natassia T; Forster, Richard M; Michael, Sean S

    2018-05-01

    Emergency Department (ED) boarding threatens patient safety. It is unclear whether boarding differentially affects patients admitted to intensive care units (ICUs) versus non-ICU settings. We performed a 2-hospital, 18-month, cross-sectional, observational, descriptive study of adult patients admitted from the ED. We used Kaplan-Meier estimation and Cox Proportional Hazards regression to describe differences in boarding time among patients who died during hospitalization versus those who survived, controlling for covariates that could affect mortality risk or boarding exposure, and separately evaluating patients admitted to ICUs versus non-ICU settings. We extracted age, race, sex, time variables, admission unit, hospital disposition, and Elixhauser comorbidity measures and calculated boarding time for each admitted patient. Among 39,781 admissions from the EDs (21.3% to ICUs), non-ICU patients who died in-hospital had a 1.2-fold risk (95% confidence interval, 1.03-1.36; P=0.016) of having experienced longer boarding times than survivors, accounting for covariates. We did not observe a difference among patients admitted to ICUs. Among non-ICU patients, those who died during hospitalization were more likely to have had incrementally longer boarding exposure than those who survived. This difference was not observed for ICU patients. Boarding risk mitigation strategies focused on ICU patients may have accounted for this difference, but we caution against interpreting that boarding can be safe. Segmentation by patients admitted to ICU versus non-ICU settings in boarding research may be valuable in ensuring that the safety of both groups is considered in hospital flow and boarding care improvements.

  7. Exposure-rate calibration using large-area calibration pads

    International Nuclear Information System (INIS)

    Novak, E.F.

    1988-09-01

    The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center (TMC) at the DOE Grand Junction Projects Office (GJPO) in Grand Junction, Colorado, to standardize, calibrate, and compare measurements made in support of DOE remedial action programs. A set of large-area, radioelement-enriched concrete pads was constructed by the DOE in 1978 at the Walker Field Airport in Grand Junction for use as calibration standards for airborne gamma-ray spectrometer systems. The use of these pads was investigated by the TMC as potential calibration standards for portable scintillometers employed in measuring gamma-ray exposure rates at Uranium Mill Tailings Remedial Action (UMTRA) project sites. Data acquired on the pads using a pressurized ionization chamber (PIC) and three scintillometers are presented as an illustration of an instrumental calibration. Conclusions and recommended calibration procedures are discussed, based on the results of these data

  8. The Impact of Process Instructions on Judges' Use of Examinee Performance Data in Angoff Standard Setting Exercises

    Science.gov (United States)

    Mee, Janet; Clauser, Brian E.; Margolis, Melissa J.

    2013-01-01

    Despite being widely used and frequently studied, the Angoff standard setting procedure has received little attention with respect to an integral part of the process: how judges incorporate examinee performance data in the decision-making process. Without performance data, subject matter experts have considerable difficulty accurately making the…

  9. Validation of five minimally obstructive methods to estimate physical activity energy expenditure in young adults in semi-standardized settings

    DEFF Research Database (Denmark)

    Schneller, Mikkel Bo; Pedersen, Mogens Theisen; Gupta, Nidhi

    2015-01-01

    We compared the accuracy of five objective methods, including two newly developed methods combining accelerometry and activity type recognition (Acti4), against indirect calorimetry, to estimate total energy expenditure (EE) of different activities in semi-standardized settings. Fourteen particip...

  10. Effectiveness of GAEC cross-compliance Standard 4.2c for biodiversity conservation in set-asides, part II (ground-dwelling Arthropods and Vertebrates

    Directory of Open Access Journals (Sweden)

    Marta Biaggini

    2016-02-01

    Full Text Available The MO.NA.CO. project has been set up to evaluate the effectiveness of some GAECs (Good Agricultural and Environmental Conditions through the institution of a monitoring network throughout the Italian territory. The present work deals with the evaluation of the Standard 4.2c, concerning biomass and biodiversity in set-asides, in relation to fauna conservation. Monitoring was performed in three areas, using the following indicators: ground-dwelling Arthropods identified at the order level, Coleoptera identified at the family level and Lacertids. Our results seem to indicate that a mild management of set-asides, consisting in mowing once a year (mid July in the examined areas, may enhance faunal diversity, above all Arthropod diversity. After mowing, the set-asides managed following Standard 4.2, hosted higher levels of Arthropod diversity and a more balanced faunistic composition in comparison to unmoved set-asides and arable lands. On the contrary, we did not find significant effects of mowing on lizard abundance. We also discussed some measures to mitigate the negative direct effects of mechanical mowing on fauna. 

  11. Disciplining standard-setting : Which approach to choose (if any)?

    NARCIS (Netherlands)

    Kanevskaia, Olia; Jacobs, Kai; Blind, Knut

    In the world of continuous globalization, standards play a crucial role in transnational economic development. Being the drivers of harmonization and innovation, standards do not only facilitate production and exchange in goods and services, but also carry significant policy implications and create

  12. Disciplining standard-setting : Which approach to choose (if any)

    NARCIS (Netherlands)

    Kanevskaia, Olia

    2017-01-01

    In the world of continuous globalization, standards play a crucial role in transnational economic development. Being the drivers of harmonization and innovation, standards do not only facilitate production and exchange in goods and services, but also carry significant policy implications and create

  13. ISO 9001:2000--setting the standard for quality management.

    Science.gov (United States)

    Edelstein, M E

    2001-04-01

    How will you approach the next quality management initiative? This article offers an introduction to the ISO 9001:2000 quality management system standards that can be applied to the HIM industry and how these standards can improve your department's policies and procedures.

  14. Measurement and Modeling of Personal Exposure to the Electric and Magnetic Fields in the Vicinity of High Voltage Power Lines

    Directory of Open Access Journals (Sweden)

    Wafa Tourab

    2016-06-01

    Conclusion: We project to set own national standards for exposure to electromagnetic fields, in order to achieve a regional database that will be at the disposal of partners concerned to ensure safety of people and mainly workers inside high voltage electrical substations.

  15. Exposure due to radon in homes - an IAEA perspective

    International Nuclear Information System (INIS)

    Navratilova-Rovenska, K.; Boal, T.; Colgan, T.

    2014-01-01

    The results of miner and residential epidemiology studies provide statistically strong evidence of harmful effects of exposure due to radon and its progeny. With the publication of the fifth edition of the International Basic Safety Standards, of the World Health Organizations Handbook on Indoor Radon and new ICRP statement on radon, there is increased interest from the public health and radiation protection authorities on controlling exposure due to radon and its progeny.The IAEA Safety Requirements publication 'Radiation Protection and Safety of Radiation Sources: International Basic Safety Standards' sets out requirements on governments for control of existing exposure situations, which includes exposure due to radon. The types of situation that are included in the scope of existing exposure situations include exposure in workplaces for which the exposure due to radon is not required by or directly related to the work and for which annual average activity concentrations due to 222 Rn must not exceed a maximum reference level of 1000 Bq/m 3 annual activity concentration, as well as exposure in dwellings and in other buildings with high occupancy factors for members of the public for which the reference level must not exceed a maximum value of 300 Bq/m 3 . These requirements include: collecting data on the activity concentrations of radon in dwellings and other buildings with high occupancy by the public; providing information on exposure due to radon and the associated health risks; and if necessary, to develop an action plan for controlling public exposure to radon. The IAEA has developed a Safety Guide to provide guidance on developing the radon action plan: 'Protection of the Public against Exposure Indoors due to Radon and Other Natural Sources of Radiation'. This presentation will summarize the information on the assistance that the IAEA is currently providing to IAEA Member States to develop radon action plans. These activities include

  16. The Relationship Between and Factors Influencing Staff Nurses' Perceptions of Nurse Manager Caring and Exposure to Workplace Bullying in Multiple Healthcare Settings.

    Science.gov (United States)

    Olender, Lynda

    2017-10-01

    The aim of this study was to examine the relationship between, and factors influencing, staff nurse perceptions of nurse manager caring (NMC) and the perceived exposure to workplace bullying (WPB) in multiple healthcare settings. Workplace bullying is commonplace, increasing, and detrimental to the health and availability of our nursing workforce. Positive relationships between a nurse manager (NM) and staff increase staff satisfaction and reduce turnover. Still unknown, however, is whether a caring relationship between manager and staff can reduce staff nurse perception of exposure to WPB. On the basis of Watson's theory that caring is reciprocal in nature, a descriptive correlational design was used to assess 156 staff nurses' self-report of NMC and their exposure to negative acts using the Caring Factor Survey-Caring of the Manager and the Negative Acts Questionnaire-Revised instruments. There is a significant inverse relationship between NMC and exposure to WPB in the nursing workplace. Gender, work environment, and a high workload influenced these findings. This study highlights the importance of caring leadership to reduce exposure to negative behaviors. The data lend support to the idea of educating NMs regarding the application of caring behaviors to support staff at the point of care.

  17. Environmental radiation standards and risk limitation

    International Nuclear Information System (INIS)

    Kocher, D.C.

    1987-01-01

    The Environmental Protection Agency and Nuclear Regulatory Commission have established environmental radiation standards for specific practices which correspond to limits on risk to the public that vary by several orders of magnitude and often are much less than radiation risks that are essentially unregulated, e.g., risks from radon in homes. This paper discusses a proposed framework for environmental radiation standards that would improve the correspondence with limitation of risk. This framework includes the use of limits on annual effective dose equivalent averaged over a lifetime, rather than limits on dose equivalent to whole body or any organ for each year of exposure, and consideration of exposures of younger age groups as well as adults; limits on annual effective dose equivalent averaged over a lifetime no lower than 0.25 mSv (25 mrem) per practice; maintenance of all exposures as low as reasonably achievable (ALARA); and establishment of a generally applicable de minimis dose for public exposures. Implications of the proposed regulatory framework for the current system of standards for limiting public exposures are discussed. 20 refs

  18. Gamma radiography of defects in concrete. Catalogue of reference exposures

    International Nuclear Information System (INIS)

    1974-01-01

    A catalogue of reference exposure as a basic document for the interpretation of gamma-radiographs of reinforced and prestressed concrete structures is presented. The radiation sources are Iridium 192, Caesium 137 and Cobalt 60. Photographic films are used as radiation detectors combined with intensifying screens and filters of lead, copper and iron. The concrete specimens were designed and made for the purpose of studying, as a function of the concrete thickness, the possibility of detecting certain characteristic incorporations or defects. Each set of standard specimens consists of seven standard blocks with the dimensions 15x15x50cm. The thicknesses of the specimens range from 15 to 75cm (1 to 5 blocks)

  19. The Effect of Realtime Monitoring on Dose Exposure to Staff Within an Interventional Radiology Setting

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, Frederic, E-mail: fredericbaumann@hotmail.com; Katzen, Barry T. [Baptist Hospital of Miami, Miami Cardiac & Vascular Institute (MCVI) (United States); Carelsen, Bart [Philips HealthCare, Clinical Science Interventional X-ray (Netherlands); Diehm, Nicolas [Kantonsspital Aarau, Clinical and Interventional Angiology (Switzerland); Benenati, James F.; Peña, Constantino S. [Baptist Hospital of Miami, Miami Cardiac & Vascular Institute (MCVI) (United States)

    2015-10-15

    PurposeThe purpose of this study is to evaluate a new device providing real-time monitoring on radiation exposure during fluoroscopy procedures intending to reduce radiation in an interventional radiology setting.Materials and MethodsIn one interventional suite, a new system providing a real-time radiation dose display and five individual wireless dosimeters were installed. The five dosimeters were worn by the attending, fellow, nurse, technician, and anesthesiologist for every procedure taking place in that suite. During the first 6-week interval the dose display was off (closed phase) and activated thereafter, for a 6-week learning phase (learning phase) and a 10-week open phase (open phase). During these phases, the staff dose and the individual dose for each procedure were recorded from the wireless dosimeter and correlated with the fluoroscopy time. Further subanalysis for dose exposure included diagnostic versus interventional as well as short (<10 min) versus long (>10 min) procedures.ResultsA total of 252 procedures were performed (n = 88 closed phase, n = 50 learning phase, n = 114 open phase). The overall mean staff dose per fluoroscopic minute was 42.79 versus 19.81 µSv/min (p < 0.05) comparing the closed and open phase. Thereby, anesthesiologists were the only individuals attaining a significant dose reduction during open phase 16.9 versus 8.86 µSv/min (p < 0.05). Furthermore, a significant reduction of total staff dose was observed for short 51 % and interventional procedures 45 % (p < 0.05, for both).ConclusionA real-time qualitative display of radiation exposure may reduce team radiation dose. The process may take a few weeks during the learning phase but appears sustained, thereafter.

  20. The Effect of Realtime Monitoring on Dose Exposure to Staff Within an Interventional Radiology Setting

    International Nuclear Information System (INIS)

    Baumann, Frederic; Katzen, Barry T.; Carelsen, Bart; Diehm, Nicolas; Benenati, James F.; Peña, Constantino S.

    2015-01-01

    PurposeThe purpose of this study is to evaluate a new device providing real-time monitoring on radiation exposure during fluoroscopy procedures intending to reduce radiation in an interventional radiology setting.Materials and MethodsIn one interventional suite, a new system providing a real-time radiation dose display and five individual wireless dosimeters were installed. The five dosimeters were worn by the attending, fellow, nurse, technician, and anesthesiologist for every procedure taking place in that suite. During the first 6-week interval the dose display was off (closed phase) and activated thereafter, for a 6-week learning phase (learning phase) and a 10-week open phase (open phase). During these phases, the staff dose and the individual dose for each procedure were recorded from the wireless dosimeter and correlated with the fluoroscopy time. Further subanalysis for dose exposure included diagnostic versus interventional as well as short (<10 min) versus long (>10 min) procedures.ResultsA total of 252 procedures were performed (n = 88 closed phase, n = 50 learning phase, n = 114 open phase). The overall mean staff dose per fluoroscopic minute was 42.79 versus 19.81 µSv/min (p < 0.05) comparing the closed and open phase. Thereby, anesthesiologists were the only individuals attaining a significant dose reduction during open phase 16.9 versus 8.86 µSv/min (p < 0.05). Furthermore, a significant reduction of total staff dose was observed for short 51 % and interventional procedures 45 % (p < 0.05, for both).ConclusionA real-time qualitative display of radiation exposure may reduce team radiation dose. The process may take a few weeks during the learning phase but appears sustained, thereafter

  1. Combined search for the standard model Higgs boson decaying to a bb pair using the full CDF data set.

    Science.gov (United States)

    Aaltonen, T; Álvarez González, B; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Apollinari, G; Appel, J A; Arisawa, T; Artikov, A; Asaadi, J; Ashmanskas, W; Auerbach, B; Aurisano, A; Azfar, F; Badgett, W; Bae, T; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Barria, P; Bartos, P; Bauce, M; Bedeschi, F; Behari, S; Bellettini, G; Bellinger, J; Benjamin, D; Beretvas, A; Bhatti, A; Binkley, M E; Bisello, D; Bizjak, I; Bland, K R; Blumenfeld, B; Bocci, A; Bodek, A; Bortoletto, D; Boudreau, J; Boveia, A; Brigliadori, L; Bromberg, C; Brucken, E; Budagov, J; Budd, H S; Burkett, K; Busetto, G; Bussey, P; Buzatu, A; Calamba, A; Calancha, C; Camarda, S; Campanelli, M; Campbell, M; Canelli, F; Carls, B; Carlsmith, D; Carosi, R; Carrillo, S; Carron, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavaliere, V; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, K; Chokheli, D; Chung, W H; Chung, Y S; Ciocci, M A; Clark, A; Clarke, C; Compostella, G; Convery, M E; Conway, J; Corbo, M; Cordelli, M; Cox, C A; Cox, D J; Crescioli, F; Cuevas, J; Culbertson, R; Dagenhart, D; d'Ascenzo, N; Datta, M; de Barbaro, P; Dell'Orso, M; Demortier, L; Deninno, M; Devoto, F; d'Errico, M; Di Canto, A; Di Ruzza, B; Dittmann, J R; D'Onofrio, M; Donati, S; Dong, P; Dorigo, M; Dorigo, T; Ebina, K; Elagin, A; Eppig, A; Erbacher, R; Errede, S; Ershaidat, N; Eusebi, R; Farrington, S; Feindt, M; Fernandez, J P; Ferrazza, C; Field, R; Flanagan, G; Forrest, R; Frank, M J; Franklin, M; Freeman, J C; Funakoshi, Y; Furic, I; Gallinaro, M; Garcia, J E; Garfinkel, A F; Garosi, P; Gerberich, H; Gerchtein, E; Giagu, S; Giakoumopoulou, V; Giannetti, P; Gibson, K; Ginsburg, C M; Giokaris, N; Giromini, P; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldin, D; Goldschmidt, N; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Goulianos, K; Grinstein, S; Grosso-Pilcher, C; Group, R C; Guimaraes da Costa, J; Hahn, S R; Halkiadakis, E; Hamaguchi, A; Han, J Y; Happacher, F; Hara, K; Hare, D; Hare, M; Harr, R F; Hatakeyama, K; Hays, C; Heck, M; Heinrich, J; Herndon, M; Hewamanage, S; Hocker, A; Hopkins, W; Horn, D; Hou, S; Hughes, R E; Hurwitz, M; Husemann, U; Hussain, N; Hussein, M; Huston, J; Introzzi, G; Iori, M; Ivanov, A; James, E; Jang, D; Jayatilaka, B; Jeans, D T; Jeon, E J; Jindariani, S; Jones, M; Joo, K K; Jun, S Y; Junk, T R; Kamon, T; Karchin, P E; Kasmi, A; Kato, Y; Ketchum, W; Keung, J; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, S B; Kim, S H; Kim, Y K; Kim, Y J; Kimura, N; Kirby, M; Klimenko, S; Knoepfel, K; Kondo, K; Kong, D J; Konigsberg, J; Kotwal, A V; Kreps, M; Kroll, J; Krop, D; Kruse, M; Krutelyov, V; Kuhr, T; Kurata, M; Kwang, S; Laasanen, A T; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; LeCompte, T; Lee, E; Lee, H S; Lee, J S; Lee, S W; Leo, S; Leone, S; Lewis, J D; Limosani, A; Lin, C-J; Lindgren, M; Lipeles, E; Lister, A; Litvintsev, D O; Liu, C; Liu, H; Liu, Q; Liu, T; Lockwitz, S; Loginov, A; Lucchesi, D; Lueck, J; Lujan, P; Lukens, P; Lungu, G; Lys, J; Lysak, R; Madrak, R; Maeshima, K; Maestro, P; Malik, S; Manca, G; Manousakis-Katsikakis, A; Margaroli, F; Marino, C; Martínez, M; Mastrandrea, P; Matera, K; Mattson, M E; Mazzacane, A; Mazzanti, P; McFarland, K S; McIntyre, P; McNulty, R; Mehta, A; Mehtala, P; Mesropian, C; Miao, T; Mietlicki, D; Mitra, A; Miyake, H; Moed, S; Moggi, N; Mondragon, M N; Moon, C S; Moore, R; Morello, M J; Morlock, J; Movilla Fernandez, P; Mukherjee, A; Muller, Th; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Naganoma, J; Nakano, I; Napier, A; Nett, J; Neu, C; Neubauer, M S; Nielsen, J; Nodulman, L; Noh, S Y; Norniella, O; Oakes, L; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Orava, R; Ortolan, L; Pagan Griso, S; Pagliarone, C; Palencia, E; Papadimitriou, V; Paramonov, A A; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Pianori, E; Pilot, J; Pitts, K; Plager, C; Pondrom, L; Poprocki, S; Potamianos, K; Prokoshin, F; Pranko, A; Ptohos, F; Punzi, G; Rahaman, A; Ramakrishnan, V; Ranjan, N; Redondo, I; Renton, P; Rescigno, M; Riddick, T; Rimondi, F; Ristori, L; Robson, A; Rodrigo, T; Rodriguez, T; Rogers, E; Rolli, S; Roser, R; Ruffini, F; Ruiz, A; Russ, J; Rusu, V; Safonov, A; Sakumoto, W K; Sakurai, Y; Santi, L; Sato, K; Saveliev, V; Savoy-Navarro, A; Schlabach, P; Schmidt, A; Schmidt, E E; Schwarz, T; Scodellaro, L; Scribano, A; Scuri, F; Seidel, S; Seiya, Y; Semenov, A; Sforza, F; Shalhout, S Z; Shears, T; Shepard, P F; Shimojima, M; Shochet, M; Shreyber-Tecker, I; Simonenko, A; Sinervo, P; Sliwa, K; Smith, J R; Snider, F D; Soha, A; Sorin, V; Song, H; Squillacioti, P; Stancari, M; St Denis, R; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Strycker, G L; Sudo, Y; Sukhanov, A; Suslov, I; Takemasa, K; Takeuchi, Y; Tang, J; Tecchio, M; Teng, P K; Thom, J; Thome, J; Thompson, G A; Thomson, E; Tipton, P; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Totaro, P; Trovato, M; Ukegawa, F; Uozumi, S; Varganov, A; Vázquez, F; Velev, G; Vellidis, C; Vidal, M; Vila, I; Vilar, R; Vizán, J; Vogel, M; Volpi, G; Wagner, P; Wagner, R L; Wakisaka, T; Wallny, R; Wang, S M; Warburton, A; Waters, D; Wester, W C; Whiteson, D; Wicklund, A B; Wicklund, E; Wilbur, S; Wick, F; Williams, H H; Wilson, J S; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, H; Wright, T; Wu, X; Wu, Z; Yamamoto, K; Yamato, D; Yang, T; Yang, U K; Yang, Y C; Yao, W-M; Yeh, G P; Yi, K; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Yu, S S; Yun, J C; Zanetti, A; Zeng, Y; Zhou, C; Zucchelli, S

    2012-09-14

    We combine the results of searches for the standard model (SM) Higgs boson based on the full CDF Run II data set obtained from sqrt[s]=1.96  TeV pp collisions at the Fermilab Tevatron corresponding to an integrated luminosity of 9.45  fb(-1). The searches are conducted for Higgs bosons that are produced in association with a W or Z boson, have masses in the range 90-150  GeV/c(2), and decay into bb pairs. An excess of data is present that is inconsistent with the background prediction at the level of 2.5 standard deviations (the most significant local excess is 2.7 standard deviations).

  2. Radiation exposure to children in intraoral dental radiology

    International Nuclear Information System (INIS)

    Looe, H. K.; Pfaffenberger, A.; Chofor, N.; Eenboom, F.; Sering, M.; Ruehmann, A.; Poplawski, A.; Willborn, K.; Poppe, B.

    2006-01-01

    In this study, dose area product (DAP) measurements have been performed aiming at establishing diagnostic reference levels (DRLs) in paediatric intraoral dental radiology. Measurements were carried out at 52 X-ray units for all types of intraoral examinations performed in clinical routine. Not all X-ray units have pre-set child exposure settings with reduced exposure time or in some cases lower tube voltage. Child examinations are carried out using adult exposure settings at these units, which increases the DAP third quartile values by up to 50%. For example, third quartile values for peri-apical examination ranges from 14.4 to 40.9 mGy cm 2 for child settings and 20.6 to 48.8 mGy cm 2 when the adult settings are included. The results show that there exists a large difference between the patient exposures among different dental facilities. It was also observed that clinics working with faster film type or higher tube voltage are not always associated with lower exposure. (authors)

  3. Exposure Plus Response-Prevention Treatment of Bulimia Nervosa.

    Science.gov (United States)

    Leitenberg, Harold; And Others

    1988-01-01

    Evaluated exposure plus response-prevention treatment of bulimia nervosa among 47 women. Subjects were assigned to either exposure plus response-prevention in one setting, exposure plus response-prevention in multiple settings, cognitive-behavioral therapy, or waiting-list control conditions. Found three treatment groups improved significantly on…

  4. Safe Handling of Snakes in an ED Setting.

    Science.gov (United States)

    Cockrell, Melanie; Swanson, Kristofer; Sanders, April; Prater, Samuel; von Wenckstern, Toni; Mick, JoAnn

    2017-01-01

    Efforts to improve consistency in management of snakes and venomous snake bites in the emergency department (ED) can improve patient and staff safety and outcomes, as well as improve surveillance data accuracy. The emergency department at a large academic medical center identified an opportunity to implement a standardized process for snake disposal and identification to reduce staff risk exposure to snake venom from snakes patients brought with them to the ED. A local snake consultation vendor and zoo Herpetologist assisted with development of a process for snake identification and disposal. All snakes have been identified and securely disposed of using the newly implemented process and no safety incidents have been reported. Other emergency department settings may consider developing a standardized process for snake disposal using listed specialized consultants combined with local resources and suppliers to promote employee and patient safety. Copyright © 2017 Emergency Nurses Association. Published by Elsevier Inc. All rights reserved.

  5. Legal and ethical standards for protecting women's human rights and the practice of conscientious objection in reproductive healthcare settings.

    Science.gov (United States)

    Zampas, Christina

    2013-12-01

    The practice of conscientious objection by healthcare workers is growing across the globe. It is most common in reproductive healthcare settings because of the religious or moral values placed on beliefs as to when life begins. It is often invoked in the context of abortion and contraceptive services, including the provision of information related to such services. Few states adequately regulate the practice, leading to denial of access to lawful reproductive healthcare services and violations of fundamental human rights. International ethical, health, and human rights standards have recently attempted to address these challenges by harmonizing the practice of conscientious objection with women's right to sexual and reproductive health services. FIGO ethical standards have had an important role in influencing human rights development in this area. They consider regulation of the unfettered use of conscientious objection essential to the realization of sexual and reproductive rights. Under international human rights law, states have a positive obligation to act in this regard. While ethical and human rights standards regarding this issue are growing, they do not yet exhaustively cover all the situations in which women's health and human rights are in jeopardy because of the practice. The present article sets forth existing ethical and human rights standards on the issue and illustrates the need for further development and clarity on balancing these rights and interests. Copyright © 2013 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  6. Outcome of Accidental Exposure Prone to Blood Borne Viral Infections in an Educational Hospital

    Directory of Open Access Journals (Sweden)

    Shahnaz Sali

    2016-04-01

    Full Text Available Background: The risk for transmission of blood-borne viruses (BBVs such as Human immunodeficiency virus (HIV, hepatitis B virus (HBV and hepatitis C virus (HCV due to occupational exposure is a major concern in the health care setting.Materials and Methods: This study among 337 health care workers (HCWs accidentally exposed to BBVs was carried out from January 2009 to March 2015. The data were reviewed in labbafinejhad hospital, Tehran, Iran.Results: 4 HCWs had exposure to HBS Ag positive, which HBS antibody titer of them was higher than 10 mlu/ml, 6 HCWs were exposed to HCV seropositive patients underwent laboratory investigations for  HCV-antibody on 4,12, 24 weeks that results were negative. 3 cases had exposure to HIV seropositive patients which received standard antiretroviral post exposure prophylaxis.Conclusion: Timely performance for PEP (Post Exposure Prophylaxis reducing BBVs transmission among HCWs.prophylaxis. Conclusions: Timely performance for  PEP(Post Exposure Prophylaxis reducing BBVs transmission among HCWs.Key words: Outcome; Accidental Exposure; Blood Borne Viral Infections

  7. Defining standardized protocols for determining the efficacy of a postmilking teat disinfectant following experimental exposure of teats to mastitis pathogens.

    Science.gov (United States)

    Schukken, Y H; Rauch, B J; Morelli, J

    2013-04-01

    The objective of this paper was to define standardized protocols for determining the efficacy of a postmilking teat disinfectant following experimental exposure of teats to both Staphylococcus aureus and Streptococcus agalactiae. The standardized protocols describe the selection of cows and herds and define the critical points in performing experimental exposure, performing bacterial culture, evaluating the culture results, and finally performing statistical analyses and reporting of the results. The protocols define both negative control and positive control trials. For negative control trials, the protocol states that an efficacy of reducing new intramammary infections (IMI) of at least 40% is required for a teat disinfectant to be considered effective. For positive control trials, noninferiority to a control disinfectant with a published efficacy of reducing new IMI of at least 70% is required. Sample sizes for both negative and positive control trials are calculated. Positive control trials are expected to require a large trial size. Statistical analysis methods are defined and, in the proposed methods, the rate of IMI may be analyzed using generalized linear mixed models. The efficacy of the test product can be evaluated while controlling for important covariates and confounders in the trial. Finally, standards for reporting are defined and reporting considerations are discussed. The use of the defined protocol is shown through presentation of the results of a recent trial of a test product against a negative control. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  8. Effects of exposure equalization on image signal-to-noise ratios in digital mammography: A simulation study with an anthropomorphic breast phantom

    Energy Technology Data Exchange (ETDEWEB)

    Liu Xinming; Lai Chaojen; Whitman, Gary J.; Geiser, William R.; Shen Youtao; Yi Ying; Shaw, Chris C. [Department of Imaging Physics, University of Texas MD Anderson Cancer Center, Houston, Texas 77030-4009 (United States); Department of Diagnostic Radiology, University of Texas MD Anderson Cancer Center, Houston, Texas 77030-4009 (United States); Department of Imaging Physics, University of Texas MD Anderson Cancer Center, Houston, Texas 77030-4009 (United States)

    2011-12-15

    Purpose: The scan equalization digital mammography (SEDM) technique combines slot scanning and exposure equalization to improve low-contrast performance of digital mammography in dense tissue areas. In this study, full-field digital mammography (FFDM) images of an anthropomorphic breast phantom acquired with an anti-scatter grid at various exposure levels were superimposed to simulate SEDM images and investigate the improvement of low-contrast performance as quantified by primary signal-to-noise ratios (PSNRs). Methods: We imaged an anthropomorphic breast phantom (Gammex 169 ''Rachel,'' Gammex RMI, Middleton, WI) at various exposure levels using a FFDM system (Senographe 2000D, GE Medical Systems, Milwaukee, WI). The exposure equalization factors were computed based on a standard FFDM image acquired in the automatic exposure control (AEC) mode. The equalized image was simulated and constructed by superimposing a selected set of FFDM images acquired at 2, 1, 1/2, 1/4, 1/8, 1/16, and 1/32 times of exposure levels to the standard AEC timed technique (125 mAs) using the equalization factors computed for each region. Finally, the equalized image was renormalized regionally with the exposure equalization factors to result in an appearance similar to that with standard digital mammography. Two sets of FFDM images were acquired to allow for two identically, but independently, formed equalized images to be subtracted from each other to estimate the noise levels. Similarly, two identically but independently acquired standard FFDM images were subtracted to estimate the noise levels. Corrections were applied to remove the excess system noise accumulated during image superimposition in forming the equalized image. PSNRs over the compressed area of breast phantom were computed and used to quantitatively study the effects of exposure equalization on low-contrast performance in digital mammography. Results: We found that the highest achievable PSNR improvement

  9. Effects of exposure equalization on image signal-to-noise ratios in digital mammography: A simulation study with an anthropomorphic breast phantom

    International Nuclear Information System (INIS)

    Liu Xinming; Lai Chaojen; Whitman, Gary J.; Geiser, William R.; Shen Youtao; Yi Ying; Shaw, Chris C.

    2011-01-01

    Purpose: The scan equalization digital mammography (SEDM) technique combines slot scanning and exposure equalization to improve low-contrast performance of digital mammography in dense tissue areas. In this study, full-field digital mammography (FFDM) images of an anthropomorphic breast phantom acquired with an anti-scatter grid at various exposure levels were superimposed to simulate SEDM images and investigate the improvement of low-contrast performance as quantified by primary signal-to-noise ratios (PSNRs). Methods: We imaged an anthropomorphic breast phantom (Gammex 169 ''Rachel,'' Gammex RMI, Middleton, WI) at various exposure levels using a FFDM system (Senographe 2000D, GE Medical Systems, Milwaukee, WI). The exposure equalization factors were computed based on a standard FFDM image acquired in the automatic exposure control (AEC) mode. The equalized image was simulated and constructed by superimposing a selected set of FFDM images acquired at 2, 1, 1/2, 1/4, 1/8, 1/16, and 1/32 times of exposure levels to the standard AEC timed technique (125 mAs) using the equalization factors computed for each region. Finally, the equalized image was renormalized regionally with the exposure equalization factors to result in an appearance similar to that with standard digital mammography. Two sets of FFDM images were acquired to allow for two identically, but independently, formed equalized images to be subtracted from each other to estimate the noise levels. Similarly, two identically but independently acquired standard FFDM images were subtracted to estimate the noise levels. Corrections were applied to remove the excess system noise accumulated during image superimposition in forming the equalized image. PSNRs over the compressed area of breast phantom were computed and used to quantitatively study the effects of exposure equalization on low-contrast performance in digital mammography. Results: We found that the highest achievable PSNR improvement factor was 1.89 for

  10. Exposure of healthy subjects with emissions from a gas metal arc welding process: part 1--exposure technique and external exposure.

    Science.gov (United States)

    Brand, P; Havlicek, P; Steiners, M; Holzinger, K; Reisgen, U; Kraus, T; Gube, M

    2013-01-01

    Studies concerning welding fume-related adverse health effects in welders are hampered by the heterogeneity of workplace situations, resulting in complex and non-standardized exposure conditions. In order to carry out welding fume exposure studies under controlled and standardized conditions, the Aachen Workplace Simulation Laboratory was developed. This laboratory consists of an emission room, in which welding fume is produced, and an exposure room in which human subjects are exposed to these fumes. Both rooms are connected by a ventilation system which allows the welding fume concentration to be regulated. Particle mass concentration was measured with a TEOM microbalance and the particle number-size distribution using a Grimm SMPS device. In a study, which is the subject of this paper, it has been shown that welding fume concentration can easily be regulated between 1 and about 3 mg m(-3). The chosen concentration can be kept constant for more than 8 h. However, transport of the particles from the emission room into the exposure room leads to a change in particle size distribution, which is probably due to coagulation of the fraction of smallest particles. The Aachen Workplace Simulation Laboratory is suitable for controlled exposure studies with human subjects.

  11. An improved set of standards for finding cost for cost-effectiveness analysis.

    Science.gov (United States)

    Barnett, Paul G

    2009-07-01

    Guidelines have helped standardize methods of cost-effectiveness analysis, allowing different interventions to be compared and enhancing the generalizability of study findings. There is agreement that all relevant services be valued from the societal perspective using a long-term time horizon and that more exact methods be used to cost services most affected by the study intervention. Guidelines are not specific enough with respect to costing methods, however. The literature was reviewed to identify the problems associated with the 4 principal methods of cost determination. Microcosting requires direct measurement and is ordinarily reserved to cost novel interventions. Analysts should include nonwage labor cost, person-level and institutional overhead, and the cost of development, set-up activities, supplies, space, and screening. Activity-based cost systems have promise of finding accurate costs of all services provided, but are not widely adopted. Quality must be evaluated and the generalizability of cost estimates to other settings must be considered. Administrative cost estimates, chiefly cost-adjusted charges, are widely used, but the analyst must consider items excluded from the available system. Gross costing methods determine quantity of services used and employ a unit cost. If the intervention will affect the characteristics of a service, the method should not assume that the service is homogeneous. Questions are posed for future reviews of the quality of costing methods. The analyst must avoid inappropriate assumptions, especially those that bias the analysis by exclusion of costs that are affected by the intervention under study.

  12. Exposure to potentially toxic hydrocarbons and halocarbons released from the dialyzer and tubing set during hemodialysis.

    Science.gov (United States)

    Lee, Hyun Ji Julie; Meinardi, Simone; Pahl, Madeleine V; Vaziri, Nostratola D; Blake, Donald R

    2012-10-01

    Although much is known about the effect of chronic kidney failure and dialysis on the composition of solutes in plasma, little is known about their impact on the composition of gaseous compounds in exhaled breath. This study was designed to explore the effect of uremia and the hemodialysis (HD) procedure on the composition of exhaled breath. Breath samples were collected from 10 dialysis patients immediately before, during, and after a dialysis session. To determine the potential introduction of gaseous compounds from dialysis components, gasses emitted from dialyzers, tubing set, dialysate, and water supplies were collected. Prospective cohort study. 10 HD patients and 10 age-matched healthy individuals. Predictors include the dialyzers, tubing set, dialysate, and water supplies before, during, and after dialysis. Changes in the composition of exhaled breath. A 5-column/detector gas chromatography system was used to measure hydrocarbon, halocarbon, oxygenate, and alkyl nitrate compounds. Concentrations of 14 hydrocarbons and halocarbons in patients' breath rapidly increased after the onset of the HD treatment. All 14 compounds and 5 others not found in patients' breath were emitted from the dialyzers and tubing sets. Contrary to earlier reports, exhaled breath ethane concentrations in our dialysis patients were virtually unchanged during the HD treatment. Single-center study with a small sample size may limit the generalizability of the findings. The study documented the release of several potentially toxic hydrocarbons and halocarbons to patients from the dialyzer and tubing sets during the HD procedure. Because long-term exposure to these compounds may contribute to the morbidity and mortality in dialysis population, this issue should be considered in the manufacturing of the new generation of dialyzers and dialysis tubing sets. Copyright © 2012 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  13. A randomized noninferiority trial of standard versus enhanced risk reduction and adherence counseling for individuals receiving post-exposure prophylaxis following sexual exposures to HIV.

    Science.gov (United States)

    Roland, Michelle E; Neilands, Torsten B; Krone, Melissa R; Coates, Thomas J; Franses, Karena; Chesney, Margaret A; Kahn, James S; Martin, Jeffrey N

    2011-07-01

    The National HIV/AIDS Strategy proposes to scale-up post-exposure prophylaxis (PEP). Intensive risk reduction and adherence counseling appear to be effective but are resource intensive. Identifying simpler interventions that maximize the HIV prevention potential of PEP is critical. A randomized noninferiority study comparing 2 (standard) or 5 (enhanced) risk reduction counseling sessions was performed. Adherence counseling was provided in the enhanced arm. We measured changes in unprotected sexual intercourse acts at 12 months, compared with baseline; HIV acquisition; and PEP adherence. Outcomes were stratified by degree of baseline risk. We enrolled 457 individuals reporting unprotected intercourse within 72 h with an HIV-infected or at-risk partner. Participants were 96% male and 71% white. There were 1.8 and 2.3 fewer unprotected sex acts in the standard and enhanced groups. The maximum potential risk difference, reflected by the upper bound of the 95% confidence interval, was 3.9 acts. The difference in the riskier subset may have been as many as 19.6 acts. The incidence of HIV seroconversion was 2.9% and 2.6% among persons randomized to standard and enhanced counseling, respectively, with a maximum potential difference of 3.4%. The absolute and maximal HIV seroconversion incidence was 9.9% and 20.4% greater in the riskier group randomized to standard, compared with enhanced, counseling. Adherence outcomes were similar, with noninferiority in the lower risk group and concerning differences among the higher-risk group. Risk assessment is critical at PEP initiation. Standard counseling is only noninferior for individuals with lower baseline risk; thus, enhanced counseling should be targeted to individuals at higher risk. © The Author 2011. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved.

  14. [Investigation of radiation dose for lower tube voltage CT using automatic exposure control].

    Science.gov (United States)

    Takata, Mitsuo; Matsubara, Kousuke; Koshida, Kichirou; Tarohda, Tohru

    2015-04-01

    The purpose of our study was to investigate radiation dose for lower tube voltage CT using automatic exposure control (AEC). An acrylic body phantom was used, and volume CT dose indices (CTDIvol) for tube voltages of 80, 100, 120, and 135 kV were investigated with combination of AEC. Average absorbed dose in the abdomen for 100 and 120 kV were also measured using thermoluminescence dosimeters. In addition, we examined noise characteristics under the same absorbed doses. As a result, the exposure dose was not decreased even when the tube voltage was lowered, and the organ absorbed dose value became approximately 30% high. And the noise was increased under the radiographic condition to be an equal absorbed dose. Therefore, radiation dose increases when AEC is used for lower tube voltage CT under the same standard deviation (SD) setting with 120 kV, and the optimization of SD setting is crucial.

  15. ISO 31000:2009--Setting a new standard for risk management.

    Science.gov (United States)

    Purdy, Grant

    2010-06-01

    Last year saw the publication of IS0 31000:2009, a new globally accepted standard for risk management together with a new, associated vocabulary in ISO Guide 73:2009. These were developed through a consensus-driven process over four years, through seven drafts, and involving the input of hundreds of risk management professionals around the world. The new standard supports a new, simple way of thinking about risk and risk management and is intended to begin the process of resolving the many inconsistencies and ambiguities that exist between many different approaches and definitions. While most decisionmakers seem to welcome the new standard and it has so far received very good reviews, it does create challenges for those who use language and approaches that are unique to their area of work but different from the new standard and guide. The need for compromise and change is the inevitable consequence of standardization.

  16. The difficulties in establishing an occupational exposure limit for carbon nanotubes

    Science.gov (United States)

    Ellenbecker, M.; Tsai, S.-J.; Jacobs, M.; Riediker, M.; Peters, T.; Liou, S.; Avila, A.; FossHansen, S.

    2018-05-01

    Concern over the health effects from the inhalation of carbon nanotubes (CNTs) has been building for some time, and adverse health effects found in animal studies include acute and chronic respiratory damage, cardiac inflammation, and cancer including mesothelioma, heretofore only associated with asbestos exposure. The strong animal evidence of toxicity requires that the occupational hygiene community develops strategies for reducing or eliminating worker exposures to CNTs; part of this strategy involves the setting of occupational exposure limits (OELs) for CNTs. A number of government agencies and private entities have established OELs for CNTs; some are mass-based, while others rely on number concentration. We review these various proposed standards and discuss the pros and cons of each approach. We recommend that specific action be taken, including intensified outreach to employers and employees concerning the potential adverse health effects from CNT inhalation, the development of more nuanced OELs that reflect the complex nature of CNT exposure, a broader discussion of these issues among all interested parties, and further research into important unanswered questions including optimum methods to evaluate CNT exposures. We conclude that current animal toxicity evidence suggests that strong action needs to be taken to minimize exposures to CNTs, and that any CNT OEL should be consistent with the need to minimize exposures.

  17. Setting pass scores for clinical skills assessment.

    Science.gov (United States)

    Liu, Min; Liu, Keh-Min

    2008-12-01

    In a clinical skills assessment, the decision to pass or fail an examinee should be based on the test content or on the examinees' performance. The process of deciding a pass score is known as setting a standard of the examination. This requires a properly selected panel of expert judges and a suitable standard setting method, which best fits the purpose of the examination. Six standard setting methods that are often used in clinical skills assessment are described to provide an overview of the standard setting process.

  18. Preliminary estimation of infantile exposure to BPA based on the standard quality of baby bottles distributed in Isfahan urban society

    Directory of Open Access Journals (Sweden)

    Zohreh Abdi Moghadam

    2013-01-01

    Full Text Available Aims: This study was aimed to estimate the bisphenol A (BPA intake from baby bottles, considering the diversity and the standard quality of the baby bottles distributed in an Isfahan urban society. Materials and Methods: A cross-sectional study was performed in Isfahan in 2011. Baby shops ( n = 33 and drug stores ( n = 7 in four district areas were included in the study. The distribution of baby bottles was investigated regarding their brand, origin, and being labeled "BPA free." Estimation of exposure to BPA from baby bottles was made based on the national and international representative data. Results: The products marked as "BPA free" were found among the western products and limited to two of the selected areas. No "BPA free" marked baby bottle was distinguished among the Iranian made products. Of the 8% exclusively formula-fed infants, 90% may be the high consumers of BPA from polycarbonate baby bottles, with an intake of 1.5-2 μg/kg b.w./day for the moderate and 7.5-10 μg/kg b.w./day in case of worse condition. Conclusion: Considering the current globally accepted threshold daily intake (TDI for BPA, primary exposure estimation is that feeding using non-BPA-free baby bottles is not a serious health concern in Iran. Thought that threshold level of TDI is discussed to be reduced in future, improvement and revision of the national standards can be effective in reducing the exposure to BPA in Iranian infants so as to provide large margin of safety for them.

  19. Setting Performance Standards for Technical and Nontechnical Competence in General Surgery.

    Science.gov (United States)

    Szasz, Peter; Bonrath, Esther M; Louridas, Marisa; Fecso, Andras B; Howe, Brett; Fehr, Adam; Ott, Michael; Mack, Lloyd A; Harris, Kenneth A; Grantcharov, Teodor P

    2017-07-01

    The objectives of this study were to (1) create a technical and nontechnical performance standard for the laparoscopic cholecystectomy, (2) assess the classification accuracy and (3) credibility of these standards, (4) determine a trainees' ability to meet both standards concurrently, and (5) delineate factors that predict standard acquisition. Scores on performance assessments are difficult to interpret in the absence of established standards. Trained raters observed General Surgery residents performing laparoscopic cholecystectomies using the Objective Structured Assessment of Technical Skill (OSATS) and the Objective Structured Assessment of Non-Technical Skills (OSANTS) instruments, while as also providing a global competent/noncompetent decision for each performance. The global decision was used to divide the trainees into 2 contrasting groups and the OSATS or OSANTS scores were graphed per group to determine the performance standard. Parametric statistics were used to determine classification accuracy and concurrent standard acquisition, receiver operator characteristic (ROC) curves were used to delineate predictive factors. Thirty-six trainees were observed 101 times. The technical standard was an OSATS of 21.04/35.00 and the nontechnical standard an OSANTS of 22.49/35.00. Applying these standards, competent/noncompetent trainees could be discriminated in 94% of technical and 95% of nontechnical performances (P < 0.001). A 21% discordance between technically and nontechnically competent trainees was identified (P < 0.001). ROC analysis demonstrated case experience and trainee level were both able to predict achieving the standards with an area under the curve (AUC) between 0.83 and 0.96 (P < 0.001). The present study presents defensible standards for technical and nontechnical performance. Such standards are imperative to implementing summative assessments into surgical training.

  20. Noise exposure and cognitive performance: A study on personnel on board Royal Norwegian Navy vessels.

    Science.gov (United States)

    Irgens-Hansen, Kaja; Gundersen, Hilde; Sunde, Erlend; Baste, Valborg; Harris, Anette; Bråtveit, Magne; Moen, Bente E

    2015-01-01

    Prior research shows that work on board vessels of the Royal Norwegian Navy (RNoN) is associated with noise exposure levels above recommended standards. Further, noise exposure has been found to impair cognitive performance in environmental, occupational, and experimental settings, although prior research in naval and maritime settings is sparse. The aim of this study was to evaluate cognitive performance after exposure to noise among personnel working on board vessels in the RNoN. Altogether 87 Navy personnel (80 men, 7 women; 31 ± 9 years) from 24 RNoN vessels were included. Noise exposure was recorded by personal noise dosimeters at a minimum of 4 h prior to testing, and categorized into 4 groups for the analysis: 85.2 dB(A). The participants performed a visual attention test based on the Posner cue-target paradigm. Multivariable general linear model (GLM) analyses were performed to analyze whether noise exposure was associated with response time (RT) when adjusting for the covariates age, alertness, workload, noise exposure in test location, sleep the night before testing, use of hearing protection device (HPD), and percentage of errors. When adjusting for covariates, RT was significantly increased among personnel exposed to >85.2 dB(A) and 77.1-85.2 dB(A) compared to personnel exposed to <72.6 dB(A).

  1. Noise exposure and cognitive performance: A study on personnel on board Royal Norwegian Navy vessels

    Directory of Open Access Journals (Sweden)

    Kaja Irgens-Hansen

    2015-01-01

    Full Text Available Prior research shows that work on board vessels of the Royal Norwegian Navy (RNoN is associated with noise exposure levels above recommended standards. Further, noise exposure has been found to impair cognitive performance in environmental, occupational, and experimental settings, although prior research in naval and maritime settings is sparse. The aim of this study was to evaluate cognitive performance after exposure to noise among personnel working on board vessels in the RNoN. Altogether 87 Navy personnel (80 men, 7 women; 31 ± 9 years from 24 RNoN vessels were included. Noise exposure was recorded by personal noise dosimeters at a minimum of 4 h prior to testing, and categorized into 4 groups for the analysis: 85.2 dB(A. The participants performed a visual attention test based on the Posner cue-target paradigm. Multivariable general linear model (GLM analyses were performed to analyze whether noise exposure was associated with response time (RT when adjusting for the covariates age, alertness, workload, noise exposure in test location, sleep the night before testing, use of hearing protection device (HPD, and percentage of errors. When adjusting for covariates, RT was significantly increased among personnel exposed to >85.2 dB(A and 77.1-85.2 dB(A compared to personnel exposed to <72.6 dB(A.

  2. Priority Setting for Occupational Cancer Prevention

    Directory of Open Access Journals (Sweden)

    Cheryl E. Peters

    2018-06-01

    Full Text Available Background: Selecting priority occupational carcinogens is important for cancer prevention efforts; however, standardized selection methods are not available. The objective of this paper was to describe the methods used by CAREX Canada in 2015 to establish priorities for preventing occupational cancer, with a focus on exposure estimation and descriptive profiles. Methods: Four criteria were used in an expert assessment process to guide carcinogen prioritization: (1 the likelihood of presence and/or use in Canadian workplaces; (2 toxicity of the substance (strength of evidence for carcinogenicity and other health effects; (3 feasibility of producing a carcinogen profile and/or an occupational estimate; and (4 special interest from the public/scientific community. Carcinogens were ranked as high, medium or low priority based on specific conditions regarding these criteria, and stakeholder input was incorporated. Priorities were set separately for the creation of new carcinogen profiles and for new occupational exposure estimates. Results: Overall, 246 agents were reviewed for inclusion in the occupational priorities list. For carcinogen profile generation, 103 were prioritized (11 high, 33 medium, and 59 low priority, and 36 carcinogens were deemed priorities for occupational exposure estimation (13 high, 17 medium, and 6 low priority. Conclusion: Prioritizing and ranking occupational carcinogens is required for a variety of purposes, including research, resource allocation at different jurisdictional levels, calculations of occupational cancer burden, and planning of CAREX-type projects in different countries. This paper outlines how this process was achieved in Canada; this may provide a model for other countries and jurisdictions as a part of occupational cancer prevention efforts. Keywords: cancer prevention, carcinogen exposure, occupational health

  3. European standards for composite construction

    NARCIS (Netherlands)

    Stark, J.W.B.

    2000-01-01

    The European Standards Organisation (CEN) has planned to develop a complete set of harmonized European building standards. This set includes standards for composite steel and concrete buildings and bridges. The Eurocodes, being the design standards, form part of this total system of European

  4. Setting Pass Scores for Clinical Skills Assessment

    Directory of Open Access Journals (Sweden)

    Min Liu

    2008-12-01

    Full Text Available In a clinical skills assessment, the decision to pass or fail an examinee should be based on the test content or on the examinees' performance. The process of deciding a pass score is known as setting a standard of the examination. This requires a properly selected panel of expert judges and a suitable standard setting method, which best fits the purpose of the examination. Six standard setting methods that are often used in clinical skills assessment are described to provide an overview of the standard setting process.

  5. Optimizing radiation exposure for CT localizer radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Bohrer, Evelyn; Maeder, Ulf; Fiebich, Martin [Univ. of Applied Sciences, Giessen (Germany). Inst. of Medical Physics and Radiation Protection-IMPS; Schaefer, Stefan; Krombach, Gabriele A. [Univ. Hospital Giessen (Germany). Dept. of Radiology; Noel, Peter B. [Technische Univ. Muenchen (Germany). Dept. of Diagnostic and Interventional Radiology

    2017-08-01

    The trend towards submillisievert CT scans leads to a higher dose fraction of localizer radiographs in CT examinations. The already existing technical capabilities make dose optimization of localizer radiographs worthwhile. Modern CT scanners apply automatic exposure control (AEC) based on attenuation data in such a localizer. Therefore not only this aspect but also the detectability of anatomical landmarks in the localizer for the desired CT scan range adjustment needs to be considered. The effective dose of a head, chest, and abdomen-pelvis localizer radiograph with standard factory settings and user-optimized settings was determined using Monte Carlo simulations. CT examinations of an anthropomorphic phantom were performed using multiple sets of acquisition parameters for the localizer radiograph and the AEC for the subsequent helical CT scan. Anatomical landmarks were defined to assess the image quality of the localizer. CTDI{sub vol} and effective mAs per slice of the helical CT scan were recorded to examine the impact of localizer settings on a helical CT scan. The dose of the localizer radiograph could be decreased by more than 90% while the image quality remained sufficient when selecting the lowest available settings (80 kVp, 20 mA, pa tube position). The tube position during localizer acquisition had a greater impact on the AEC than the reduction of tube voltage and tube current. Except for the use of a pa tube position, all changes of acquisition parameters for the localizer resulted in a decreased total radiation exposure. A dose reduction of CT localizer radiograph is necessary and possible. In the examined CT system there was no negative impact on the modulated helical CT scan when the lowest tube voltage and tube current were used for the localizer.

  6. Controlling occupational radiation exposure. Alternatives to regulation

    International Nuclear Information System (INIS)

    Sagan, L.A.; Squitieri, R.; Wildman, S.S.

    1980-01-01

    The principal strategy adopted for the control of occupational radiation exposure has been the establishment of standards expressed as maximum permissible exposures. The use of such standards is subject to a number of defects, among which is the neglect of the economic impact of imposing such standards. Furthermore, such standards carry the implication of a threshold for radiation effects, a concept now widely challenged. Lastly, the use of standards makes it impossible to evaluate the efficiency of the regulatory agency or to compare its performance with other similar agencies. An alternative to the use of standards, i.e. cost-benefit analysis, is discussed. The advantages of this technique meet many of the objections to the use of standards alone and allow health and safety resources to be allocated in a manner most likely to save the most lives. The greatest disadvantage of cost-benefit analysis has been the difficulty in evaluating the benefit side of the equation. Although the risks of radiation exposure are not known with precision, they are nevertheless well understood. Therefore, the application of cost-benefit analysis to occupational radiation exposure is rational. There are a number of barriers to reform in the use of standards and the adoption of cost-benefit analysis. These attitudinal and institutional constraints are discussed. The nature of private or market systems of control are discussed, i.e. the use of liability and insurance mechanisms. These also have shortcomings that require further development but are seen as potentially more efficient for both employer and employee than is the use of regulatory standards. (author)

  7. [Study on standardization of cupping technique: elucidation on the establishment of the National Standard Standardized Manipulation of Acupuncture and Moxibustion, Part V, Cupping].

    Science.gov (United States)

    Gao, Shu-zhong; Liu, Bing

    2010-02-01

    From the aspects of basis, technique descriptions, core contents, problems and solutions, and standard thinking in standard setting process, this paper states experiences in the establishment of the national standard Standardized Manipulation of Acupuncture and Moxibustion, Part V, Cupping, focusing on methodologies used in cupping standard setting process, the method selection and operating instructions of cupping standardization, and the characteristics of standard TCM. In addition, this paper states the scope of application, and precautions for this cupping standardization. This paper also explaines tentative ideas on the research of standardized manipulation of acupuncture and moxibustion.

  8. Electric power industrial applications comply with electromagnetic field thresholds set by the CENELEC standards; Les applications industrielles de l`electricite respectent les seuils de champ electromagnetique imposes par la normalisation Cenelec

    Energy Technology Data Exchange (ETDEWEB)

    Hutzler, B.; Deschamps, F. [Laboratoires de Genie Electrique (France)

    1996-12-31

    Electricite de France (EDF) has carried out theoretical modeling and in-situ measurements in its own plants and in industrial plants, in order to verify the compliance of electromagnetic field exposure to the future european CENELEC standard concerning electromagnetic exposure for the employees. Except in the immediate proximity of certain equipment, which are generally not working places, the exposure values are lower than the specified limitations. Field reduction techniques are proposed for critical equipment

  9. UVR exposures in Australia are high: can they be reduced?

    Energy Technology Data Exchange (ETDEWEB)

    Gies, Peter; Makin, Jen; Dobbinson, Suzanne; Javorniczky, John; Henderso, Stuart; King, Kerryn [Australian Radiation Protection and Nuclear Safety Agency, Miranda (Australia)

    2011-10-15

    Australians have high UVR exposures for a number of reasons, mainly because of their geographical location resulting in high levels of ambient solar UVR but also because of their lifestyle and time spent outdoors. Numerous Australian studies have made measurements of the UVR doses individuals in various high risk groups such as outdoor workers and children receive and these results, summarised in this presentation, indicate that the doses are high. Given skin cancer is preventable by reducing exposures to UVR, can these exposures be significantly reduced? Considerable effort has already gone into trying to reduce both the leisure time and occupational exposures of the population through multiple strategies including public education in media campaigns and establishment and monitoring of compliance to an occupational exposure standard N. More detailed information about which activities and behaviours contribute the major UV exposures in the population and the outdoor workforce would allow more accurately targeted campaigns to reduce those UV exposures. The availability and use of the new technology of time-stamped personal UV dosimeters outlined in this presentation in a number of projects working with at risk groups could provide the more detailed information of UVR exposures required and then facilitate the targeted campaigns and help reduce UVR exposures. One other avenue for Australians to get harmful UVR exposures is by using solaria, where recent work [2] has shown Australian solaria to have some of the highest UV emissions of in the world. Considerable effort has been made over the last few years to remove self regulation by the solarium industry and introduce government regulations independent of the industry. The introduction of a standard set of regulations in each State and Territory governing the procedures and practices in solaria will have improved the situation significantly. Specifically, some state surveys have shown increasing levels of compliance

  10. Protecting workers from pathogens. Employers must act now to comply with OSHA's new standard on bloodborne pathogens.

    Science.gov (United States)

    White, C L

    1992-04-01

    A new standard set forth by the Occupational Safety and Health Administration (OSHA) requires healthcare employers to implement sweeping new controls in areas such as record keeping, engineering, hazard prevention, and work practice. Through the bloodborne pathogen standard, which went into effect on March 6, OSHA acknowledges that healthcare workers face significant health risks as a result of occupational exposure to blood and other infectious materials. Although most prudent healthcare providers already adhere to the Centers for Disease Control's universal precautions, the OSHA regulations include several additional mandatory measures that are more specific and stringent. The additional measures include the development of an exposure control plan, procedures for responding to an employee's exposure to bloodborne pathogens, the implementation of certain engineering and work practice controls to eliminate or minimize on-the-job exposure risks, and the provision of personal protective equipment and information and training programs. OSHA estimates that the greatest cost component of implementing procedures to bring a facility into compliance is attributable to the purchase of personal protective equipment. Although the costs of compliance are substantial, OSHA has estimated that these costs represent less than 1 percent of the healthcare industry's annual revenues. Violation of the bloodborne pathogen standard may result in penalties of up to $70,000, depending on the severity of the infraction. Criminal penalties are also possible for willful violations that result in worker death.

  11. Telemetry Standards, RCC Standard 106-17. Chapter 9. Telemetry Attributes Transfer Standard

    Science.gov (United States)

    2017-07-01

    DIAM-n) IMAGE FRAME RATE (R-x\\ IFR -n) PRE-TRIGGER FRAMES (R-x\\PTG-n) TOTAL FRAMES (R-x\\TOTF-n) EXPOSURE TIME (R-x\\EXP-n) SENSOR ROTATION...Multi-frame). “2” (Continuous). Allowed when: R\\CDT is “IMGIN” IMAGE FRAME RATE R-x\\ IFR -n R/R Ch 10 Status: RO Frame rate in frames per second... impact : A partial IHAL <configuration> element containing only the new settings for everything that has changed: • The new values for the settings

  12. ACCOUNTABILITY WITHIN NEW OZONE STANDARDS

    Science.gov (United States)

    Over the past two decades, as part of the effort to develop the National Ambient Air Quality Standards (NAAQS), researchers have been using real human exposure data to help analyze the magnitude and extent of the risks from specific or multiple pollutants. Surrogates for exposur...

  13. Changing Default Fluoroscopy Equipment Settings Decreases Entrance Skin Dose in Patients.

    Science.gov (United States)

    Canales, Benjamin K; Sinclair, Lindsay; Kang, Diana; Mench, Anna M; Arreola, Manuel; Bird, Vincent G

    2016-04-01

    Proper fluoroscopic education and protocols may reduce the patient radiation dose but few prospective studies in urology have been performed. Using optically stimulated luminescent dosimeters we tested whether fluoroscopy time and/or entrance skin dose would decrease after educational and radiation reduction protocols. At default manufacturer settings fluoroscopy time and entrance skin dose were prospectively measured using optically stimulated luminescent dosimeters in patients undergoing ureteroscopy, retrograde pyelogram/stent or percutaneous nephrolithotomy with access for stone disease. A validated radiation safety competency test was administered to urology faculty and residents before and after web based, hands-on fluoroscopy training. Default fluoroscopy settings were changed from continuous to intermittent pulse rate and from standard to half-dose output. Fluoroscopy time and entrance skin dose were then measured again. The cohorts of 44 pre-protocol and 50 post-protocol patients with stones were similarly matched. The change in mean fluoroscopy time and entrance skin dose from pre-protocol to post-protocol was -0.6 minutes and -11.6 mGy (33%) for percutaneous nephrolithotomy (p = 0.62 and default settings to intermittent pulse rate (12 frames per second) and half-dose lowered the entrance skin dose by 30% across all endourology patients but most significantly during percutaneous nephrolithotomy. To limit patient radiation exposure fluoroscopy default settings should be decreased before all endourology procedures and image equipment manufacturers should consider lowering standard default renal settings. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  14. Consideration of the overall impact of an emission when setting standards for air pollution control

    International Nuclear Information System (INIS)

    Van As, D.

    1981-01-01

    By increasing the release height, dispersion of the effluent is improved and thus the release rate that can be tolerated for the same air concentration at ground level is also increased. Stacks are thus often misapplied if the ground-level concentration alone is taken into account, while total release, and thus the overall impact, are disregarded. In the nuclear industry the control of radioactive releases to the environment is based on two important requirements, viz.: dose limits (air-quality standards) may under no circumstances be exceeded, and; doses should be kept as low as reasonably achievable, which requires that total exposure from all doses, even those well below the dose limit, to all members of the public and for all future time, should be considered. Permissible releases are determined by taking into account the overall impact of the release and optimising the release to the point where the cost of further decreasing the amount is not justified by the additional protection obtained [af

  15. The development of standard operating protocols for paediatric radiology

    International Nuclear Information System (INIS)

    Hardwick, J.; Mencik, C.; McLaren, C.; Young, C.; Scadden, S.; Mashford, P.; McHugh, K.; Beckett, M.; Calvert, M.; Marsden, P.J.

    2001-01-01

    This paper describes how the requirement for operating protocols for standard radiological practice was expanded to provide a comprehensive aide to the operator conducting a medical exposure. The protocols adopted now include justification criteria, patient preparation, radiographic technique, standard exposure charts, diagnostic reference levels and image quality criteria. In total, the protocols have been welcomed as a tool for ensuring that medical exposures are properly optimised. (author)

  16. Standard practice for modified salt spray (fog) testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This practice covers and sets forth conditions for five modifications in salt spray (fog) testing for specification purposes. These are in chronological order of their development: 1.1.1 Annex A1, acetic acid-salt spray test, continuous. 1.1.2 Annex A2, cyclic acidified salt spray test. 1.1.3 Annex A3, seawater acidified test, cyclic (SWAAT). 1.1.4 Annex A4, SO2 salt spray test, cyclic. 1.1.5 Annex A5, dilute electrolyte cyclic fog dry test. 1.2 This practice does not prescribe the type of modification, test specimen or exposure periods to be used for a specific product, nor the interpretation to be given to the results. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to consult and establish appropriate safety and health practices and determine the applicabilit...

  17. Slope across the Curriculum: Principles and Standards for School Mathematics and Common Core State Standards

    Science.gov (United States)

    Nagle, Courtney; Moore-Russo, Deborah

    2014-01-01

    This article provides an initial comparison of the Principles and Standards for School Mathematics and the Common Core State Standards for Mathematics by examining the fundamental notion of slope. Each set of standards is analyzed using eleven previously identified conceptualizations of slope. Both sets of standards emphasize Functional Property,…

  18. Overview of the development of the Korean exposure factors handbook.

    Science.gov (United States)

    Jang, Jae-Yeon; Jo, Soo-Nam; Kim, So-Yeon; Myung, Hyung-Nam

    2014-01-01

    A set of exposure factors that reflects the characteristics of individual behavior capable of influencing exposure is essential for risk and exposure assessment. In 2007, the Korean Exposure Factors Handbook was, therefore, issued, driven by the need to develop reliable exposure factors representing the Korean population. The purpose of this study was to overview the development process of the Korean Exposure Factors Handbook and major recommended exposure values for the Korean population to allow information exchanges and comparison of recommended values among nations. The researchers reviewed the domestic data that could be used in the development of exposure factors, confirmed a knowledge gap, and set a priority of development by phases. A methodology to measure exposure factors was established to develop measuring techniques and test their validity. Data were processed or a survey was conducted according to the availability of data. The study thus produced recommended values for 24 exposure factors grouped by general exposure factors, food ingestion factors, and activity factors by setting up a database of exposure factors and carrying out statistical analysis. The study has significantly contributed to reducing the potential uncertainty of the risk and exposure assessment derived by the application of foreign data or research findings lacking representativeness or grounds by developing a set of exposure factors reflecting the characteristics of the Korean people. It will be necessary to conduct revisions in light of the changing statistical values of national data and the exposure factors based on Korean characteristics.

  19. Varied exposure to carcinogenic, mutagenic, and reprotoxic (CMR) chemicals in occupational settings in France

    Energy Technology Data Exchange (ETDEWEB)

    Havet, Nathalie [Univ. Claude Bernard Lyon 1 (France). Lab. SAF; Penot, Alexis [Lyon Univ. (France). ENS Lyon, GATE-UMR 5824-CNRS; Morelle, Magali; Perrier, Lionel [Lyon Univ. (France). Direction de la Recherche Clinique et de l' Innovation; Charbotel, Barbara [Univ. Claude Bernard Lyon 1 (France). Centre Hospitalier Lyon Sud Service des Maladies Professionnelles; Fervers, Beatrice [Lyon Univ. (France). Dept. Cancer and Environment

    2017-02-15

    To explore varied exposure to carcinogenic, mutagenic, and reprotoxic chemicals (CMR) for French employees. Our study assessed data from the French national cross-sectional survey of occupational risks (SUMER) that was conducted in 2010 in a national representative sample of employees. We selected 28 CMR agents that were classified by the International Agency for Research on Cancer or European Union as being known or presumed to have CMR potential in humans. The association of individual and job characteristics with exposure prevalence, duration, and intensity of the CMR agents during a 1-week period was examined using multilevel logistic regression analysis. Overall, 10.4% of employees in 2010 were exposed to one or more CMR agents at their workplace, and 3.4% were subjected to multiple CMR exposures. Blue-collar workers, night-shift workers and workers with short-term employment contracts experienced higher exposure prevalence (p < 0.01) and intensity (p < 0.05). Bluecollar workers and shift workers experienced also longer exposure duration (p < 0.001). Conversely, managers, workers of large companies, and women were less exposed to CMR agents (p < 0.001). The presence of a Committee for Health, Safety, and Working Conditions, and intervention by Occupational Health and Safety officers were significantly associated with reduced exposure intensities (p < 0.001 and p < 0.05). Establishment of European CMR regulations and the existence of an applicable substitution principle reduced the exposure duration (p < 0.001) and intensity (p < 0.05). Our results point out disparities in CMR exposure and identify high-priority targets for prevention measures to help reducing social health discrepancies.

  20. Varied exposure to carcinogenic, mutagenic, and reprotoxic (CMR) chemicals in occupational settings in France

    International Nuclear Information System (INIS)

    Havet, Nathalie; Penot, Alexis; Morelle, Magali; Perrier, Lionel; Charbotel, Barbara; Fervers, Beatrice

    2017-01-01

    To explore varied exposure to carcinogenic, mutagenic, and reprotoxic chemicals (CMR) for French employees. Our study assessed data from the French national cross-sectional survey of occupational risks (SUMER) that was conducted in 2010 in a national representative sample of employees. We selected 28 CMR agents that were classified by the International Agency for Research on Cancer or European Union as being known or presumed to have CMR potential in humans. The association of individual and job characteristics with exposure prevalence, duration, and intensity of the CMR agents during a 1-week period was examined using multilevel logistic regression analysis. Overall, 10.4% of employees in 2010 were exposed to one or more CMR agents at their workplace, and 3.4% were subjected to multiple CMR exposures. Blue-collar workers, night-shift workers and workers with short-term employment contracts experienced higher exposure prevalence (p < 0.01) and intensity (p < 0.05). Bluecollar workers and shift workers experienced also longer exposure duration (p < 0.001). Conversely, managers, workers of large companies, and women were less exposed to CMR agents (p < 0.001). The presence of a Committee for Health, Safety, and Working Conditions, and intervention by Occupational Health and Safety officers were significantly associated with reduced exposure intensities (p < 0.001 and p < 0.05). Establishment of European CMR regulations and the existence of an applicable substitution principle reduced the exposure duration (p < 0.001) and intensity (p < 0.05). Our results point out disparities in CMR exposure and identify high-priority targets for prevention measures to help reducing social health discrepancies.

  1. Standard practice for exposure of metals and alloys by alternate immersion in neutral 3.5% Sodium Chloride solution

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This practice covers procedures for making alternate immersion stress corrosion tests in 3.5 % sodium chloride (NaCl) (). It is primarily for tests of aluminum alloys (Test Method G 47) and ferrous alloys, but may be used for other metals exhibiting susceptibility to chloride ions. It sets forth the environmental conditions of the test and the means for controlling them. Note 1 Alternate immersion stress corrosion exposures are sometimes made in substitute ocean water (without heavy metals) prepared in accordance with Specification D 1141. The general requirements of this present practice are also applicable to such exposures except that the reagents used, the solution concentration, and the solution pH should be as specified in Specification D 1141. 1.2 This practice can be used for both stressed and unstressed corrosion specimens. Historically, it has been used for stress-corrosion cracking testing, but is often used for other forms of corrosion, such as uniform, pitting, intergranular, and galvanic. ...

  2. Standard operating procedures improve acute neurologic care in a sub-Saharan African setting.

    Science.gov (United States)

    Jaiteh, Lamin E S; Helwig, Stefan A; Jagne, Abubacarr; Ragoschke-Schumm, Andreas; Sarr, Catherine; Walter, Silke; Lesmeister, Martin; Manitz, Matthias; Blaß, Sebastian; Weis, Sarah; Schlund, Verena; Bah, Neneh; Kauffmann, Jil; Fousse, Mathias; Kangankan, Sabina; Ramos Cabrera, Asmell; Kronfeld, Kai; Ruckes, Christian; Liu, Yang; Nyan, Ousman; Fassbender, Klaus

    2017-07-11

    Quality of neurologic emergency management in an under-resourced country may be improved by standard operating procedures (SOPs). Neurologic SOPs were implemented in a large urban (Banjul) and a small rural (Brikama) hospital in the Gambia. As quality indicators of neurologic emergency management, performance of key procedures was assessed at baseline and in the first and second implementation years. At Banjul, 100 patients of the first-year intervention group exhibited higher rates of general procedures of emergency management than 105 control patients, such as neurologic examination (99.0% vs 91.4%; p process quality of neurologic emergency management in under-resourced settings. This study provides Class IV evidence that, for patients with suspected neurologic emergencies in sub-Saharan Africa, neurologic SOPs increase the rate of performance of guideline-recommended procedures. Copyright © 2017 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Neurology.

  3. A case of standardization?

    DEFF Research Database (Denmark)

    Rod, Morten Hulvej; Høybye, Mette Terp

    2016-01-01

    the ones envisioned by the makers of standards. In 2012, the Danish National Health Authorities introduced a set of health promotion guidelines that were meant to guide the decision making and priority setting of Denmark's 98 local governments. The guidelines provided recommendations for health promotion...... and standardization. It remains an open question whether or not the guidelines lead to more standardized policies and interventions, but we suggest that the guidelines promote a risk factor-oriented approach as the dominant frame for knowledge, reasoning, decision making and priority setting in health promotion. We...

  4. Does modern helicopter construction reduce noise exposure in helicopter rescue operations?

    Science.gov (United States)

    Küpper, Thomas; Jansing, Paul; Schöffl, Volker; van Der Giet, Simone

    2013-01-01

    During helicopter rescue operations the medical personnel are at high risk for hearing damage by noise exposure. There are two important factors to be taken into account: first, the extreme variability, with some days involving no exposure but other days with extreme exposure; second, the extreme noise levels during work outside the helicopter, e.g. during winch operations. The benefit of modern, less noisier constructions and the consequences for noise protection are still unknown. We estimated the noise exposure of the personnel for different helicopter types used during rescue operations in the Alps and in other regions of the world with special regard to the advanced types like Eurocopter EC 135 to compare the benefit of modern constructions for noise protection with earlier ones. The rescue operations over 1 year of four rescue bases in the Alps (Raron and Zermatt in Switzerland; Landeck and Innsbruck in Austria, n = 2731) were analyzed for duration of rescue operations (noise exposure). Noise levels were measured during rescue operations at defined points inside and outside the different aircraft. The setting is according to the European standard (Richtlinie 2003/10/EG Amtsblatt) and to Class 1 DIN/IEC 651. With both data sets the equivalent noise level L(eq8h) was calculated. For comparison it was assumed that all rescue operations were performed with a specific type of helicopter. Then model calculations for noise exposure by different helicopter types, such as Alouette IIIb, Alouette II 'Lama', Ecureuil AS350, Bell UH1D, Eurocopter EC135, and others were performed. Depending on modern technologies the situation for the personnel has been improved significantly. Nevertheless noise prevention, which includes noise intermissions in spare time, is essential. Medical checks of the crews by occupational medicine (e.g. 'G20' in Germany) are still mandatory.

  5. Ranking system for national regulatory jurisdictions based on pesticide standard values in major exposures

    Directory of Open Access Journals (Sweden)

    Zijian Li

    2017-07-01

    Full Text Available To control the risk of human exposure to pesticides, about 50 nations have promulgated pesticide soil regulatory guidance values (RGVs, and 104 nations have provided pesticide drinking water maximum concentration levels (MCLs. In addition, 90 nations have regulated pesticide agricultural commodity maximum residue limits (MRLs. Pesticide standard values (PSVs for one single pesticide varied in a range of six, seven, or even eight orders of magnitude. Some PSVs are too large to prevent the impact of pesticides on human health. Many nations have not provided PSVs for some commonly used pesticides until now. This research has introduced several completeness values and numerical values methods to evaluate the national jurisdiction’s performance on PSVs on a nation base. The national jurisdiction ranking system developed by these methods will be beneficial to the environmental regulation makers in the management of PSVs. Results also indicate that European countries perform better in the regulation of pesticide soil RGVs, drinking water MCLs, and agricultural commodity MRLs.

  6. Setting standards for planning off duty and audit of practice.

    Science.gov (United States)

    Walker, Linda; Minchin, Anne; Pickard, Jane

    The off duty or rostering system is an important part of managing any ward or department. This article looks at the issues that need to be considered when drawing up and managing off duty. It recommends standards for off-duty planning and shares the results of an audit carried out against some of these standards in one NHS trust.

  7. [Exposure to fluorides from drinking water in the city of Aguascalientes, Mexico].

    Science.gov (United States)

    Trejo-Vázquez, R; Bonilla-Petriciolet, A

    2001-08-01

    Determine the fluoride content in all the wells that supply drinking water to the city of Aguascalientes, Mexico, in order to establish the population's degree of exposure. The fluoride content of the 126 wells that supply drinking water to the city of Aguascalientes was determined, using the SPADNS method, in accordance with two Mexican regulations, NMX-AA-77-1982 and NMX-014-SSAI-1993. Using that data, we created fluoride isopleth maps showing the distribution of fluoride concentrations in the water supplies for the city of Aguascalientes. We also estimated exposure doses for the city's inhabitants. The mean analysis uncertainty was 3.9%. Seventy-three wells had a fluoride concentration of" 1.5 mg/L, which was the maximum permissible value set by the Mexican standards then in effect. All the maximum exposure doses surpassed the minimum risk level set by Agency for Toxic Substances and Disease Registry (ATSDR) of the Department of Health and Human Services of the United States of America. In the children under 1 year of age, even the minimum does was slightly higher than the ATSDR risk level. From estimating the fluoride exposure doses caused by water consumption in the city of Aguascalientes and comparing those doses with ones from other states in Mexico, we concluded that the fluoride intake in Aguascalientes represents a potential risk for inhabitants' health. The fluoride content of the city's drinking water should be reduced to 0.69 mg/L.

  8. Local dialogue and information within the frame of the setting up of relay antennas. Decreasing the exposure to electromagnetic waves emitted by mobile phone relay antennas. First phase report by Francois Brottes, chairman of the 'experimentations' COMOP

    International Nuclear Information System (INIS)

    Brottes, Francois

    2011-01-01

    The first part of this report describes the progress made on local dialogue and information within the frame of the setting up of relay antennas. It describes the implemented method with a selection of nine local communities, the main results of the dialogue (establishment of an information file, development of a tool set for the pilot communities, and operation, steering and assessment of experimentations). The second part describes the progress made on the exposure of population to electromagnetic waves emitted by mobile phone relay antennas (context, method, exposure status, simulation of the decreasing of relay antenna power, site experimentations). The third part proposes a set of recommendations related to local dialogue and information and to exposure

  9. Role of the IAEA in establishment of the international standards of radiation protection

    International Nuclear Information System (INIS)

    Pinak, M.

    2014-01-01

    The aim of the presentation is to highlight the existing challenges in radiation protection, and provide insight into the role of the IAEA in establishment of the radiation safety standards. It will, inter alia, cover from the following areas: 1. global outreach of safety principles in radiation protection and safety; 2. IAEA and establishment of Safety Standards; 3. IAEA Standards and national regulations; 4. IAEA members states role in drafting and review of IAEA Safety Standards; 5. existing, novel issues and challenges. The role of the IAEA is to establish fundamental safety objectives in radiation protection and safety following fundamental safety objectives, safety principles and concepts. The main aim of Safety Standards is to provide for the establishment of a system for protection of people and the environment from harmful effects of ionizing radiation. The requirements as included in the Safety Standards aim to assess, manage and control exposure to radiation so that radiation risks, including risks of health effects and risks to the environment, are reduced to the extent reasonably achievable.One of the novel feature adopted in the revised Basic Safety Standards (BSS) is the classification of exposures - planned, emergency and existing - each of them including several categories of exposure (occupational, public and medical), where appropriate.The revised BSS also addresses areas like exemption and clearance being particularly important in international trade and transport; significantly increases the number of requirements in medicine, in response to novel and/or expanding techniques in medicine using ionizing radiation; incorporates new regulatory limits for exposure to radon, and in protection of the lens of the eyes, as recommended by WHO and ICRP; newly introduces requirements for specific practices like, for example, airport security screenings; and addresses many other areas.While the principal approach to regulatory aspects in emergency exposure

  10. Skin exposure to isocyanates: reasons for concern.

    Science.gov (United States)

    Bello, Dhimiter; Herrick, Christina A; Smith, Thomas J; Woskie, Susan R; Streicher, Robert P; Cullen, Mark R; Liu, Youcheng; Redlich, Carrie A

    2007-03-01

    Isocyanates (di- and poly-), important chemicals used worldwide to produce polyurethane products, are a leading cause of occupational asthma. Respiratory exposures have been reduced through improved hygiene controls and the use of less-volatile isocyanates. Yet isocyanate asthma continues to occur, not uncommonly in settings with minimal inhalation exposure but opportunity for skin exposure. In this review we evaluate the potential role of skin exposure in the development of isocyanate asthma. We reviewed the published animal and human literature on isocyanate skin-exposure methods, workplace skin exposure, skin absorption, and the role of skin exposure in isocyanate sensitization and asthma. We selected relevant articles from computerized searches on Medline, U.S. Environmental Protection Agency, Occupational Safety and Health Administration, National Institute for Occupational Safety and Health, and Google databases using the keywords "isocyanate," "asthma," "skin," "sensitization," and other synonymous terms, and our own extensive collection of isocyanate publications. Isocyanate production and use continues to increase as the polyurethane industry expands. There is substantial opportunity for isocyanate skin exposure in many work settings, but such exposure is challenging to quantify and continues to be underappreciated. Isocyanate skin exposure can occur at work, even with the use of personal protective equipment, and may also occur with consumer use of certain isocyanate products. In animals, isocyanate skin exposure is an efficient route to induce sensitization, with subsequent inhalation challenge resulting in asthma-like responses. Several lines of evidence support a similar role for human isocyanate skin exposure, namely, that such exposure occurs and can contribute to the development of isocyanate asthma in certain settings, presumably by inducing systemic sensitization. Integrated animal and human research is needed to better understand the role of skin

  11. The Information System on Occupational Exposure in Medicine, Industry and Research (ISEMIR): Interventional Cardiology

    International Nuclear Information System (INIS)

    2014-02-01

    In the last three decades, the use of image guided interventional procedures in cardiology has increased significantly, bringing great benefit to millions of patients around the world. As technology improves, the medical capabilities of these procedures continue to expand, adding further to the armamentarium for diagnosis and treatment of patients with cardiac problems. All of these procedures require health professionals (including interventional cardiologists, electrophysiologists, nurses and medical radiation technologists) to be present in the room and alongside the patient when radiation is being used, which may result in occupational exposure. While it has been long known that there is significant potential for health professionals in attendance during interventional cardiology to receive non-trivial occupational exposures, reported details have been typically limited to a few specific interventional cardiology facilities and situations. A more global perspective has been lacking, as is the availability of a systematic means for improving occupational radiation protection in interventional cardiology facilities throughout the world. In 2006, the IAEA published the Fundamental Safety Principles (IAEA Safety Standards Series No. SF-1), which sets out the fundamental safety objective and principles of protection and safety. In 2011, the IAEA published Radiation Protection and Safety of Sources: International Basic Safety Standards (IAEA Safety Standards Series No. GSR Part 3 (Interim Edition)), which sets out the requirements for meeting the fundamental safety objective and applying the principles specified in the Fundamental Safety Principles. The establishment of safety requirements and provision of guidance on occupational radiation protection is a major component of the support for radiation protection and safety provided by the IAEA to Member States. This publication was developed under the IAEA's statutory responsibility to facilitate worldwide application

  12. Determining a Consistent Set of Accounting and Financial Reporting Standards : A Research Note Based on the IASB-FASB Conceptual Framework Revision Project

    OpenAIRE

    Le Manh-Béna, Anne; Ramond, Olivier,

    2011-01-01

    Following the debate on the Conceptual Framework revision undertaken by the IASB and the FASB, this paper discusses three major concerns about the way financial reporting standards should be determined: (1) What is the role a Conceptual Framework?; (2) For whom and for which needs are accounting and financial reporting standards made?; and (3) What information set should financial reporting provide? We show that the perceived need of a Framework has resulted in practice in weak usefulness We ...

  13. Double bag or Y-set versus standard transfer systems for continuous ambulatory peritoneal dialysis in end-stage kidney disease.

    Science.gov (United States)

    Daly, Conal; Cody, June D; Khan, Izhar; Rabindranath, Kannaiyan S; Vale, Luke; Wallace, Sheila A

    2014-08-13

    Peritonitis is the most frequent serious complication of continuous ambulatory peritoneal dialysis (CAPD). It has a major influence on the number of patients switching from CAPD to haemodialysis and has probably restricted the wider acceptance and uptake of CAPD as an alternative mode of dialysis.This is an update of a review first published in 2000. This systematic review sought to determine if modifications of the transfer set (Y-set or double bag systems) used in CAPD exchanges are associated with a reduction in peritonitis and an improvement in other relevant outcomes. We searched the Cochrane Renal Group's Specialised Register through contact with the Trials Search Co-ordinator. Studies contained in the Specialised Register are identified through search strategies specifically designed for CENTRAL, MEDLINE and EMBASE. Date of last search: 22 October 2013. Randomised controlled trials (RCTs) or quasi-RCTs comparing double bag, Y-set and standard peritoneal dialysis (PD) exchange systems in patients with end-stage kidney disease. Data were abstracted by a single investigator onto a standard form and analysed by Review Manager. Analysis was by a random effects model and results were expressed as risk ratio (RR) or mean difference (MD) with 95% confidence intervals (CI). Twelve eligible trials with a total of 991 randomised patients were identified. Despite the large total number of patients, few trials covered the same interventions, small numbers of patients were enrolled in each trial and the methodological quality was suboptimal. Y-set and twin-bag systems were superior to conventional spike systems (7 trials, 485 patients, RR 0.64, 95% CI 0.53 to 0.77) in preventing peritonitis in PD. Disconnect systems should be the preferred exchange systems in CAPD.

  14. Challenges and perspectives of nanoparticle exposure assessment.

    Science.gov (United States)

    Lee, Ji Hyun; Moon, Min Chaul; Lee, Joon Yeob; Yu, Il Je

    2010-06-01

    Nanoparticle exposure assessment presents a unique challenge in the field of occupational and environmental health. With the commercialization of nanotechnology, exposure usually starts from the workplace and then spreads to environment and consumer exposure. This report discusses the current trends of nanoparticle exposure assessment, including the definition of nanotechnology relevant terms, essential physicochemical properties for nanomaterial characterization, current international activities related nanomaterial safety, and exposure assessment standard development for nanotechnology. Further this report describes challenges of nanoparticle exposure assessment such as background measurement, metrics of nanoparticle exposure assessment and personal sampling.

  15. Sound Exposure of Healthcare Professionals Working with a University Marching Band.

    Science.gov (United States)

    Russell, Jeffrey A; Yamaguchi, Moegi

    2018-01-01

    Music-induced hearing disorders are known to result from exposure to excessive levels of music of different genres. Marching band music, with its heavy emphasis on brass and percussion, is one type that is a likely contributor to music-induced hearing disorders, although specific data on sound pressure levels of marching bands have not been widely studied. Furthermore, if marching band music does lead to music-induced hearing disorders, the musicians may not be the only individuals at risk. Support personnel such as directors, equipment managers, and performing arts healthcare providers may also be exposed to potentially damaging sound pressures. Thus, we sought to explore to what degree healthcare providers receive sound dosages above recommended limits during their work with a marching band. The purpose of this study was to determine the sound exposure of healthcare professionals (specifically, athletic trainers [ATs]) who provide on-site care to a large, well-known university marching band. We hypothesized that sound pressure levels to which these individuals were exposed would exceed the National Institute for Occupational Safety and Health (NIOSH) daily percentage allowance. Descriptive observational study. Eight ATs working with a well-known American university marching band volunteered to wear noise dosimeters. During the marching band season, ATs wore an Etymotic ER-200D dosimeter whenever working with the band at outdoor rehearsals, indoor field house rehearsals, and outdoor performances. The dosimeters recorded dose percent exposure, equivalent continuous sound levels in A-weighted decibels, and duration of exposure. For comparison, a dosimeter also was worn by an AT working in the university's performing arts medicine clinic. Participants did not alter their typical duties during any data collection sessions. Sound data were collected with the dosimeters set at the NIOSH standards of 85 dBA threshold and 3 dBA exchange rate; the NIOSH 100% daily dose is

  16. Use of environmental TLD data at a nuclear power station to estimate detection limits for radiation exposure due to station operation

    International Nuclear Information System (INIS)

    Lang, E.; Hardeman, J.; Kahn, B.

    1987-01-01

    The environmental radiation monitoring network maintained by the Georgia Department of Natural Resources at the Hatch Nuclear Plant, Baxley, GA, was used to determine the variability in measured background exposures in order to estimate the detection limits for radiation due to station operation. Data were obtained from LiF thermoluminescent dosimeters (TLDs) exposed in sets of four at 46 locations for 16 consecutive quarters from 1982 to 1985. The average exposure for 695 values was 11.8 microC kg-1 y-1 (mR/quarter). At individual locations, the averages of quarterly exposures ranged from 9.3 to 14.3 microC kg-1 y-1 and had standard deviations from 0.8 to 2.2 microC kg-1 y-1 with a typical standard deviation of 1.5 microC kg-1 y-1. The standard deviation due to reading the TLDs and subtracting the transit plus storage exposure, estimated as 0.4 microC kg-1 y-1, contributed only a small fraction of the uncertainty of the mean background; the greater contribution is from temporal fluctuations. There is a spatial pattern of higher background along the Altamaha River but no distinct seasonal pattern. The observation that exposure values at most locations rose and fell in unison suggested a calculational model that adjusts the average exposure level at a location by an increment determined each quarter at control locations. This model reduced the standard deviation for a predicted quarterly background exposure to 0.9 microC kg-1 y-1, with a range of 0.5 to 1.3 microC kg-1 y-1. If the standard deviation of the net value is multiplied by an error probability constant of 3.3 (type I and II errors not greater than 5%), the detection limits range from 2 to 5 microC kg-1 y-1 at the individual locations, with an average of 3 microC kg-1 y-1. This approach or two similar ones described earlier are recommended for improving the detection limit where needed

  17. Exposure to Indoor Allergens in Different Residential Settings and Its Influence on IgE Sensitization in a Geographically Confined Austrian Cohort.

    Directory of Open Access Journals (Sweden)

    Teresa Stemeseder

    Full Text Available Exposure to indoor allergens is crucial for IgE sensitization and development of allergic symptoms. Residential settings influence the allergen amount in house dust and hence allergic sensitization. Within this study, we investigated allergen exposure and molecule-based IgE levels in a geographically confined region and evaluated the impact of housing, pets and cleaning.501 adolescents from Salzburg, Austria participated in this cross-sectional study. House dust samples were examined regarding major mite, cat, dog, and mold allergens using a multiplex assay. Serum samples of participants were analyzed for specific IgE to Der p 1, Der p 2, Fel d 1, Can f 1 and Alt a 1 using the multiplex array ImmunoCAP ISAC. Information on allergies, living areas, dwelling form (house, flat, farm, pets, and household cleanliness were obtained by a questionnaire.In investigated house dust samples, the concentration of cat allergen was highest while the prevalence of mold allergens was very low. Participants showed IgE sensitization to Der p 1 (13.2%, Der p 2 (18.2%, Fel d 1 (14.4%, Can f 1 (2.4% and Alt a 1 (2.0%. In alpine regions, lower mite allergen concentrations were detected which correlated with reduced IgE levels. A trend for increased sensitization prevalence from rural to alpine to urban regions was noted. Living on farms resulted in lower sensitization prevalence to mite and cat allergens, even though exposure to mites was significantly elevated. The presence of cats was associated with a lower sensitization rate and IgE levels to cat and mite allergens, and less frequent allergic diseases. Cleaning did not impact allergen concentrations, while IgE reactivity to mites and allergic diseases were more pronounced when living in cleaner homes.Allergen exposure to indoor allergens was influenced by setting of homes. Living in a farm environment and having a cat at home showed a protective effect for IgE sensitization and allergies. This cross

  18. General philosophy of safety standards

    International Nuclear Information System (INIS)

    Dunster, H.J.

    1987-01-01

    Safety standards should be related to the form and magnitude of the risk they aim to limit. Because of the lack of direct information at the exposure levels experienced, radiation protection standards have to be based on risk assumptions that, while plausible, are not proven. The pressure for standards has come as much from public perceptions and fears as from the reality of the risk. (author)

  19. The International Accounting Standards Board’s Progress in Promoting Judgement Through Objectives-Oriented Accounting Standards

    Directory of Open Access Journals (Sweden)

    Tanja Lakovic

    2013-07-01

    Full Text Available This study analyzes how the International Accounting Standards Board (IASB promotes professional judgement by issuing objectives-oriented accounting standards and exposure drafts.  We focus on the the role of judgement as outlined in Phase I of the IASB Conceptual Framework (CF, Chapter 1, “Objective of General Purpose Financial Statements” and Chapter 3, “Qualitative Characteristics of Useful Financial Information” (IASB 2010. We discuss how the framework, when viewed through the prism of 'objectives-oriented accounting standards' as recommended by the United States Securities and Exchange Commission (SEC Report in its “Study Pursuant to Section 108(d of the Sarbanes-Oxley Act of 2002 on the Adoption by the United States Financial Reporting System of a Principles-Based Accounting System” (July 2003, encourages professional judgement. We analyze International Financial Reporting Standards (IFRS and Exposure Drafts (ED issued by the IASB since its inception in 2002 to determine if those documents are consistent with objectives-oriented accounting standards. Our analysis is useful for gaining insights into how the IASB integrates the CF with the SEC’s recommended objectives-oriented accounting approach to promote judgement in the interest of IASB/FASB convergence of accounting standards.

  20. Some practical applications of fundamental standards in radiation protection

    International Nuclear Information System (INIS)

    Duhamel, Francis; Lavie, Jean-Marie

    1964-05-01

    After some general considerations on the recommendations made by the International Commission on Radiological Protection (ICRP) regarding standards of internal or external exposure of organs or tissues to different types of radiations, and a recall of the main problems raised by acute radio-exposures (dose assessment in case of accident, assessment of the dose due to an emergency intervention in case of accident, classification of radio-elements), this report describes how ICRP recommendations have been implemented by the CEA, and tries to relate the problem of acute radio-exposures to the problem of chronic radio-exposures. This study is limited to the case of workers and to internal contamination by inhalation, but can be easily extended to other groups or other contamination types. The authors thus recall some fundamental data and definitions regarding values recommended by the ICRP for chronic radio-exposure and for acute exposure (acceptable exposure, accidental exposure, concerted exposure, units), present and comment how standards are practically applied for dose calculation and assessment. Formulas allow a quick assessment of radiological consequences of an acute radio-exposure, or vice-versa [fr

  1. Using the Many-Faceted Rasch Model to Evaluate Standard Setting Judgments: An Illustration with the Advanced Placement Environmental Science Exam

    Science.gov (United States)

    Kaliski, Pamela K.; Wind, Stefanie A.; Engelhard, George, Jr.; Morgan, Deanna L.; Plake, Barbara S.; Reshetar, Rosemary A.

    2013-01-01

    The many-faceted Rasch (MFR) model has been used to evaluate the quality of ratings on constructed response assessments; however, it can also be used to evaluate the quality of judgments from panel-based standard setting procedures. The current study illustrates the use of the MFR model for examining the quality of ratings obtained from a standard…

  2. Standard Setting for Next Generation TOEFL Academic Speaking Test (TAST): Reflections on the ETS Panel of International Teaching Assistant Developers

    Science.gov (United States)

    Papajohn, Dean

    2006-01-01

    While many institutions have utilized TOEFL scores for international admissions for many years, a speaking section has never before been a required part of TOEFL until the development of the iBT/Next Generation TOEFL. So institutions will need to determine how to set standards for the speaking section of TOEFL, also known as TOEFL Academic…

  3. Health effects of laser printer emissions: a controlled exposure study.

    Science.gov (United States)

    Karrasch, S; Simon, M; Herbig, B; Langner, J; Seeger, S; Kronseder, A; Peters, S; Dietrich-Gümperlein, G; Schierl, R; Nowak, D; Jörres, R A

    2017-07-01

    Ultrafine particles emitted from laser printers are suspected to elicit adverse health effects. We performed 75-minute exposures to emissions of laser printing devices (LPDs) in a standardized, randomized, cross-over manner in 23 healthy subjects, 14 mild, stable asthmatics, and 15 persons reporting symptoms associated with LPD emissions. Low-level exposures (LLE) ranged at the particle background (3000 cm -3 ) and high-level exposures (HLE) at 100 000 cm -3 . Examinations before and after exposures included spirometry, body plethysmography, transfer factors for CO and NO (TLCO, TLNO), bronchial and alveolar NO, cytokines in serum and nasal secretions (IL-1β, IL-5, IL-6, IL-8, GM-CSF, IFNγ, TNFα), serum ECP, and IgE. Across all participants, no statistically significant changes occurred for lung mechanics and NO. There was a decrease in volume-related TLNO that was more pronounced in HLE, but the difference to LLE was not significant. ECP and IgE increased in the same way after exposures. Nasal IL-6 showed a higher increase after LLE. There was no coherent pattern regarding the responses in the participant subgroups or single sets of variables. In conclusion, the experimental acute responses to short but very high-level LPD exposures were small and did not indicate clinically relevant effects compared to low particle number concentrations. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Determination of x-radiation exposure rates from color television sets

    International Nuclear Information System (INIS)

    Campos, L.L.; Caldas, L.V.E.

    1988-05-01

    The exposure rates of low energy X-rays emitted from color televisions were determined by thermoluminescence using CaSO 4 :Dy + Teflon pellets. The measurements were taken at the distances of 5 cm, 2 and 3 m in front of the screens. The results were compared with those obtained for video display terminals at the same experimental conditions. (author) [pt

  5. Medical exposure and the effects of radiation

    International Nuclear Information System (INIS)

    Okuyama, Chio

    2011-01-01

    Radiation gives cracks to genes. The influence is divided into deterministic effect with a threshold value, and the stochastic effect (tumor and genetic effect) which increases according to the exposure amount. Although we are put to various non-artificial radiations, which we cannot be avoided, on the earth, the contamination by artificial radiation can be defended. Artificial radioactive exposure includes medical exposure and non-medical exposure for example by nuclear power plant. As to medical examinations using radiation, the inquiry about the radiation exposure is increasing after the occurrence of the first nuclear power plant disaster of Fukushima. While concern about non-medical radioactive exposure increases, the uneasiness to medical irradiation is also increasing. The dose limit by artificial radioactive exposure other than medical exposure is set up in order to prevent the influence on the health. While the dose limit of the public exposure is set to the lower value than the total dose of non-artificial exposure concerning of a safety margin for all people, the dose limit of medical exposure is not defined, since it is thought that medical irradiation has a benefit for those who receive irradiation. Making an effort to decrease the radiation dose in performing the best medical treatment is the responsibility with which we are burdened. (author)

  6. [Evaluation standards and application for photography of schistosomiasis control theme].

    Science.gov (United States)

    Chun-Li, Cao; Qing-Biao, Hong; Jing-Ping, Guo; Fang, Liu; Tian-Ping, Wang; Jian-Bin, Liu; Lin, Chen; Hao, Wang; You-Sheng, Liang; Jia-Gang, Guo

    2018-02-26

    To set up and apply the evaluation standards for photography of schistosomiasis control theme, so as to offer the scientific advice for enriching the health information carrier of schistosomiasis control. Through the literature review and expert consultation, the evaluation standard for photography of schistosomiasis control theme was formulated. The themes were divided into 4 projects, such as new construction, natural scenery, working scene, and control achievements. The evaluation criteria of the theme photography were divided into the theme (60%), photographic composition (15%), focus exposure (15%), and color saturation (10%) . A total of 495 pictures (sets) from 59 units with 77 authors were collected from schistosomiasis epidemic areas national wide. After the first-step screening and second-step evaluation, the prizes of 3 themes of control achievements and new construction, working scene, and natural scenery were selected, such as 6 pictures of first prize, 12 pictures of second prize, 18 pictures of third prize, and 20 pictures of honorable prize. The evaluation standards of theme photography should be taken into the consideration of the technical elements of photography and the work specification of schistosomiasis prevention and control. In order to improve the ability of records for propaganda purpose of schistosomiasis control and better play a role of guiding correct propaganda, the training and guidance of photography of professionals should be carried out.

  7. Solar set asides and renewable electricity certificates: Early lessons from North Carolina's experience with its renewable portfolio standard

    International Nuclear Information System (INIS)

    Gaul, Chip; Carley, Sanya

    2012-01-01

    This paper assesses the market developments in North Carolina's solar energy industry following the state's adoption of a renewable portfolio standard (RPS). It first reviews how solar renewable electricity certificates (SRECs) are intended to act as a support mechanism for the installation and financing of solar power in North Carolina's RPS compliance market. The paper then analyzes why SRECs have not precipitated growth in the solar industry thus far. Instead of attracting a diversity of solar installation and SREC trading businesses to create a competitive market to North Carolina, the RPS has only enabled a few large solar power producers to compete with utility companies to finance, install, and operate solar generating systems. A comparison between the SREC markets in North Carolina, Pennsylvania, and New Jersey reveals that transparency in prices and volumes of SRECs, limits on utility company self-ownership of solar generators, and more aggressive solar set-aside targets are required to create a competitive market environment that will attract a sustainable and growing solar industry. - Highlights: ► Assesses developments in NC's solar industry from renewable portfolio standard. ► Comparisons between the SREC markets in North Carolina, Pennsylvania, New Jersey. ► Transparency in prices and limits on utility self-ownership are necessary. ► More aggressive solar set-aside targets would also help develop the solar market.

  8. Optimization of radiation protection in the control of occupational exposure

    International Nuclear Information System (INIS)

    2003-01-01

    One of the three main principles on which protection against ionizing radiation is based is the principle of the optimization of radiological protection. The principle of the optimization of protection was first enunciated by the International Commission on Radiological Protection in the 1960s. A principal requirement for the optimization of protection and safety has been incorporated into the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (Basic Safety Standards) from the first edition in 1962 up to the current (1996) edition. The principle of optimization, that all reasonable efforts be made to reduce doses (social and economic factors being taken into account), necessitates considerable effort to apply in practice. The requirement of the Basic Safety Standards to apply the principle of optimization applies to all categories of exposure: occupational, public and medical. The categories of public and medical exposure are rather specific and are covered in other publications. This Safety Report concentrates on the application of the principle to what is probably the largest category, that of occupational exposure. This Safety Report provides practical information on how to apply the optimization of protection in the workplace. The emphasis throughout is on the integration of radiation protection into the more general system of work management, and on the involvement of management and workers in setting up a system of radiation protection and in its implementation. This Safety Report was drafted and finalized in three consultants meetings held in 1999 and 2000. The draft was sent for review and comment to a number of experts, which yielded valuable comments from a number of reviewers whose names are included in the list of contributors to drafting and review

  9. Optimization of radiation protection in the control of occupational exposure

    International Nuclear Information System (INIS)

    2002-01-01

    One of the three main principles on which protection against ionizing radiation is based is the principle of the optimization of radiological protection. The principle of the optimization of protection was first enunciated by the International Commission on Radiological Protection in the 1960s. A principal requirement for the optimization of protection and safety has been incorporated into the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (Basic Safety Standards) from the first edition in 1962 up to the current (1996) edition. The principle of optimization, that all reasonable efforts be made to reduce doses (social and economic factors being taken into account), necessitates considerable effort to apply in practice. The requirement of the Basic Safety Standards to apply the principle of optimization applies to all categories of exposure: occupational, public and medical. The categories of public and medical exposure are rather specific and are covered in other publications; this Safety Report concentrates on the application of the principle to what is probably the largest category, that of occupational exposure. This Safety Report provides practical information on how to apply the optimization of protection in the workplace. The emphasis throughout is on the integration of radiation protection into the more general system of work management, and on the involvement of management and workers in setting up a system of radiation protection and in its implementation. This Safety Report was drafted and finalized in three consultants meetings held in 1999 and 2000. The draft was sent for review and comment to a number of experts, which yielded valuable comments from a number of reviewers whose names are included in the list of contributors to drafting and review

  10. Optimization of radiation protection in the control of occupational exposure

    International Nuclear Information System (INIS)

    2004-01-01

    One of the three main principles on which protection against ionizing radiation is based is the principle of the optimization of radiological protection. The principle of the optimization of protection was first enunciated by the International Commission on Radiological Protection in the 1960s. A principal requirement for the optimization of protection and safety has been incorporated into the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (Basic Safety Standards) from the first edition in 1962 up to the current (1996) edition. The principle of optimization, that all reasonable efforts be made to reduce doses (social and economic factors being taken into account), necessitates considerable effort to apply in practice. The requirement of the Basic Safety Standards to apply the principle of optimization applies to all categories of exposure: occupational, public and medical. The categories of public and medical exposure are rather specific and are covered in other publications. This Safety Report concentrates on the application of the principle to what is probably the largest category, that of occupational exposure. This Safety Report provides practical information on how to apply the optimization of protection in the workplace. The emphasis throughout is on the integration of radiation protection into the more general system of work management, and on the involvement of management and workers in setting up a system of radiation protection and in its implementation. This Safety Report was drafted and finalized in three consultants meetings held in 1999 and 2000. The draft was sent for review and comment to a number of experts, which yielded valuable comments from a number of reviewers whose names are included in the list of contributors to drafting and review

  11. Why quasi-sets?

    Directory of Open Access Journals (Sweden)

    Décio Krause

    2002-11-01

    Full Text Available Quasi-set theory was developed to deal with collections of indistinguishable objects. In standard mathematics, there are no such kind of entities, for indistinguishability (agreement with respect to all properties entails numerical identity. The main motivation underlying such a theory is of course quantum physics, for collections of indistinguishable (’identical’ in the physicists’ jargon particles cannot be regarded as ’sets’ of standard set theories, which are collections of distinguishable objects. In this paper, a rationale for the development of such a theory is presented, motivated by Heinz Post’s claim that indistinguishability ofquantum entities should be attributed ’right at the start’.

  12. Ultraviolet and short wavelength visible light exposure: why ultraviolet protection alone is not adequate.

    Science.gov (United States)

    Reichow, Alan W; Citek, Karl; Edlich, Richard F

    2006-01-01

    The danger of exposure to ultraviolet (UV) radiation in both the natural environment and artificial occupational settings has long been recognized by national and international standards committees and worker safety agencies. There is an increasing body of literature that suggests that protection from UV exposure is not enough. Unprotected exposure to the short wavelengths of the visible spectrum, termed the "blue light hazard", is gaining acceptance as a true risk to long-term visual health. Global standards and experts in the field are now warning that those individuals who spend considerable time outdoors should seek sun filter eyewear with high impact resistant lenses that provide 100% UV filtration, high levels of blue light filtration, and full visual field lens/frame coverage as provided by high wrap eyewear. The Skin Cancer Foundation has endorsed certain sunglasses as "product[s]...effective [as] UV filter[s] for the eyes and surrounding skin". However, such endorsement does not necessarily mean that the eyewear meets all the protective needs for outdoor use. There are several brands that offer products with such protective characteristics. Performance sun eyewear by Nike Vision, available in both corrective and plano (nonprescription) forms, is one such brand incorporating these protective features.

  13. Exposure scenario libraries as a tool for exposure assessment

    International Nuclear Information System (INIS)

    Jiménez, Araceli Sánchez; Rashid, Shahzad; Van Tongeren, Martie; Brouwer, Derk; Fransman, Wouter; Fito, Carlos; Boulougouris, George

    2015-01-01

    The development of nanotechnology has reached a point where it is being widely applied, and numerous nanomaterials and nano-enabled products are handled across a broad range of industrial sectors. Exposure extends beyond occupational settings as products containing nanomaterials are used by different consumer groups.Despite the knowledge on their toxic effects is growing there is still not OEL for most NMS and therefore the precautionary approach is still used where levels are kept as low as possible Therefore there is a need to assess workers and consumers exposure. (paper)

  14. Scoring and setting pass/fail standards for an essay certification examination in nurse-midwifery.

    Science.gov (United States)

    Fullerton, J T; Greener, D L; Gross, L J

    1992-03-01

    Examination for certification or licensure of health professionals (credentialing) in the United States is almost exclusively of the multiple choice format. The certification examination for entry into the practice of the profession of nurse-midwifery has, however, used a modified essay format throughout its twenty-year history. The examination has recently undergone a revision in the method for score interpretation and for pass/fail decision-making. The revised method, described in this paper, has important implications for all health professional credentialing agencies which use modified essay, oral or practical methods of competency assessment. This paper describes criterion-referenced scoring, the process of constructing the essay items, the methods for assuring validity and reliability for the examination, and the manner of standard setting. In addition, two alternative methods for increasing the validity of the pass/fail decision are evaluated, and the rationale for decision-making about marginal candidates is described.

  15. Cost-effectiveness of omalizumab add-on to standard-of-care therapy in patients with uncontrolled severe allergic asthma in a Brazilian healthcare setting.

    Science.gov (United States)

    Suzuki, Cibele; Lopes da Silva, Nilceia; Kumar, Praveen; Pathak, Purnima; Ong, Siew Hwa

    2017-08-01

    Omalizumab add-on to standard-of-care therapy has proven to be efficacious in severe asthma patients for whom exacerbations cannot be controlled otherwise. Moreover, evidence from different healthcare settings suggests reduced healthcare resource utilization with omalizumab. Based on these findings, this study aimed to assess the cost-effectiveness of the addition of omalizumab to standard-of-care therapy in patients with uncontrolled severe allergic asthma in a Brazilian healthcare setting. A previously published Markov model was adapted using Brazil-specific unit costs to compare the costs and outcomes of the addition of omalizumab to standard-of-care therapy vs standard-of-care therapy alone. Model inputs were largely based on the eXpeRience study. Costs and health outcomes were calculated for lifetime-years and were annually discounted at 5%. Both one-way and probabilistic sensitivity analyses were performed. An additional cost of R$280,400 for 5.20 additional quality-adjusted life-years was estimated with the addition of omalizumab to standard-of-care therapy, resulting in an incremental cost-effectiveness ratio of R$53,890. One-way sensitivity analysis indicated that discount rates, standard-of-care therapy exacerbation rates, and exacerbation-related mortality rates had the largest impact on incremental cost-effectiveness ratios. Assumptions of lifetime treatment adherence and rate of future exacerbations, independent of previous events, might affect the findings. The lack of Brazilian patients in the eXpeRience study may affect the findings, although sample size and baseline characteristics suggest that the modeled population closely resembles Brazilian severe allergic asthma patients. Results indicate that omalizumab as an add-on therapy is more cost-effective than standard-of-care therapy alone for Brazilian patients with uncontrolled severe allergic asthma, based on the World Health Organization's cost-effectiveness threshold of up to 3-times the gross

  16. Radiation exposure during ESWL

    International Nuclear Information System (INIS)

    McCullough, D.L.; Van Swearingen, F.L.; Dyer, R.B.; Appel, B.

    1987-01-01

    This paper discusses exposure to ionizing radiation by the ESWL patient and for health professionals. Although the patient is exposed acutely to the highest level of radiation, the lithotripter team is chronically exposed to ionizing radiation at varying levels. Attention to detail is important in reducing that exposure. The operator should follow the guidelines set forth in this chapter in order to minimize exposure to the patient, himself or herself, and to all co-workers. At the present time, investigation of an alternative modality for stone localization, ultrasound, is being investigated

  17. The Flaws of Fragmented Financial Standard Setting

    DEFF Research Database (Denmark)

    Mügge, Daniel; Perry, James

    2014-01-01

    rating, accounting, and derivatives trading, this article demonstrates why the appropriateness of the organizational architecture of global financial governance is necessarily contingent upon one’s understanding of how financial markets work. In particular, if financial markets are not anchored......In the half decade following the 2007 financial crisis, the reform of global financial governance was driven by two separate policy debates: one on the substantive content of regulations, the other on the organizational architecture of their governance. The separation of the two debates among...... policymakers has been mirrored in academia, where postcrisis analyses of financial governance have remained detached from reinvigorated discussions about the nature of financial markets. We argue that this separation is deeply flawed. Presenting an analysis of interactions between standards for banking, credit...

  18. Health effects of long-term exposure to air pollution: An overview of major respiratory and cardiovascular diseases and diabetes

    Directory of Open Access Journals (Sweden)

    Jovanovic-Andersen Zorana

    2012-01-01

    Full Text Available Large number of studies provided convincing evidence for adverse effects of exposure to outdoor air pollution on human health, and served as basis for current USA and EU Air Quality Standards and limit values. Still, new knowledge is emerging, expanding our understanding of vast effects of exposure to air pollution on human health of this ubiquitous exposure affecting millions of people in urban setting. This paper focuses on the studies of health effects of long-term (chronic exposures to air pollution, and includes major chronic and acute diseases in adults and especially elderly, which will present increasing public health burden, due to improving longevity and projected increasing numbers of elderly. The paper gives overview over the most relevant and latest literature presented by different health outcomes: chronic obstructive pulmonary disease, asthma, pneumonia, cardiovascular disease, and diabetes.

  19. Studies on the calibration of mammography automatic exposure mode with computed radiology

    International Nuclear Information System (INIS)

    Zhu Hongzhou; Shao Guoliang; Shi Lei; Liu Qing

    2010-01-01

    Objective: To realize the optimization of image quality and radiation dose by correcting mammography automatic exposure, according to automatic exposure controlled mode of mammography film-screen system. Methods: The film-screen system (28 kV) was applied to perform automatic exposure of plexiglass (40 mm) and get the standard dose of exposure, the exposure mode of CR base on LgM=2.0 was rectified, which was divided into 10 steps. Mammary glands pattern (Fluke NA18-220) were examined with CR (26, 28, and 30 kV) by the automatic exposure mode corrected. The exposure values (mAs) were recorded. CR image was diagnosed and evaluated in double blind way by 4 radiologists according to American Collage of Radiology (ACR) standard. Results: Based on the standard of CR automatic exposure with the dose higher than the traditional exposure of film-screen system, the calibration of mammography automatic exposure was accomplished. The test results of the calibrated mode was better than the scoring system of ACR. Conclusions: Comparative study showed improvement in acquiring high-quality image and reduction of radiation dose. The corrected mammography automatic exposure mode might be a better method for clinical use. (authors)

  20. Reducing the number of options on multiple-choice questions: response time, psychometrics and standard setting.

    Science.gov (United States)

    Schneid, Stephen D; Armour, Chris; Park, Yoon Soo; Yudkowsky, Rachel; Bordage, Georges

    2014-10-01

    Despite significant evidence supporting the use of three-option multiple-choice questions (MCQs), these are rarely used in written examinations for health professions students. The purpose of this study was to examine the effects of reducing four- and five-option MCQs to three-option MCQs on response times, psychometric characteristics, and absolute standard setting judgements in a pharmacology examination administered to health professions students. We administered two versions of a computerised examination containing 98 MCQs to 38 Year 2 medical students and 39 Year 3 pharmacy students. Four- and five-option MCQs were converted into three-option MCQs to create two versions of the examination. Differences in response time, item difficulty and discrimination, and reliability were evaluated. Medical and pharmacy faculty judges provided three-level Angoff (TLA) ratings for all MCQs for both versions of the examination to allow the assessment of differences in cut scores. Students answered three-option MCQs an average of 5 seconds faster than they answered four- and five-option MCQs (36 seconds versus 41 seconds; p = 0.008). There were no significant differences in item difficulty and discrimination, or test reliability. Overall, the cut scores generated for three-option MCQs using the TLA ratings were 8 percentage points higher (p = 0.04). The use of three-option MCQs in a health professions examination resulted in a time saving equivalent to the completion of 16% more MCQs per 1-hour testing period, which may increase content validity and test score reliability, and minimise construct under-representation. The higher cut scores may result in higher failure rates if an absolute standard setting method, such as the TLA method, is used. The results from this study provide a cautious indication to health professions educators that using three-option MCQs does not threaten validity and may strengthen it by allowing additional MCQs to be tested in a fixed amount

  1. Asbestos exposure in Israel: findings, issues and needs

    Energy Technology Data Exchange (ETDEWEB)

    Richter, E.D.

    1984-02-01

    In Israel, since the 1950s, at least several thousand workers, their wives and children, and possibly many others, have been or still may be exposed to hazardous amounts of airborne asbestos fibers. These are found both in asbestos-based industries (asbestos cement, textiles and brake linings) and trades with asbestos exposure (construction, shipyard repair, boiler maintenance, insulation work). These people are at increased risk for disability or illness, or for premature death from asbestosis, from lung cancer, from exacerbation of preexisting respiratory disease (especially if they smoke), from mesothelioma, from gastrointestinal cancer, and from other malignancies. Although there has been progress, much still has to be done in the areas of legislation, standard setting, exposure control, technology, surveillance, smoking cessation, and medical care and follow-up. Compensation is needed to care for those workers currently or previously exposed, as well as for their families and others at risk. A national policy for protecting and caring for those formerly or currently exposed is indicated by the review of the situation in Israel.

  2. Political and Economic Theory of Standards.

    OpenAIRE

    Vandemoortele, Thijs

    2011-01-01

    Standards are increasingly important in the global market system. Consumers rely progressively more on public standards (set by governments) as well as private standards (set by firms) to make their consumption decisions. Similarly producers rely heavily on standards to gear their production systems to one another and to increase transparency and traceability throughout the supply chain. Standards address a large variety of issues in consumption and production such as nutritional (e.g. low fa...

  3. Human exposure to polyhexamethylene guanidine phosphate from humidifiers in residential settings: Cause of serious lung disease.

    Science.gov (United States)

    Lee, Ji Hyun; Yu, Il Je

    2017-11-01

    Exposure to the humidifier disinfectant, polyhexamethylene guanidine phosphate (PHMG), in mists generated from ultrasonic humidifiers was studied in a simulation chamber and apartment rooms. PHMG is suspected as a causative agent of lung disease in Korea residences. In the simulation-chamber study, the amount of disinfectant discharged from three different ultrasonic humidifiers was measured. Mists generated at 1, 2, and 4 times the recommended amount of disinfectant were sampled with an impinger, and the effect of relative humidity (RH) on airborne disinfectant concentration was studied by changing RH from 60%-70% to 90%-100%. In addition, particle size distribution (PSD) in mists was measured by scanning mobility particle sizer (SMPS), aerodynamic particle sizer (APS), and Mastersizer. In the apartment study, mists generated from ultrasonic humidifiers were sampled for 6 h in small and large rooms during fall ( n = 10) and winter ( n = 15). In the simulation study, the humidifiers discharged 205 ± 24.6 ml/h of mist at maximum capacity. Concentrations of airborne disinfectant increased with increasing concentration of disinfectant. RH affected airborne disinfectant concentration in the chamber, with increasing concentration with increasing RH. Below RH 70%, no airborne PHMG was detected. PHMG-containing mists generated from ultrasonic humidifier showed various sizes ranging from 149-157 nm to 690-740 nm to larger than 5.4 µm by SMPS, APS, and Mastersizer, respectively. Surface area mean diameter measured by Mastersizer ranged from 5.39 µm to 5.72 µm. In the apartment study conducted during the fall, the geometric mean (GM) and geometric standard deviation (GSD) and arithmetic mean (AM) and standard deviation (SD) of airborne PHMG concentration were 3.22 + 5.13 µg/m 3 and 8.26 ± 12.18 µg/m 3 , respectively. In the winter, GM + GSD and AM ± SD of airborne PHMG concentration were 0.21 + 2.11 µg/m 3 and 0.35 ± 0.62 µg/m 3 , respectively. RH and temperature

  4. How Do Nurses Manage Their Occupational Exposure to Cytotoxic Drugs? A Descriptive Survey in Chemotherapy Settings, Shiraz, Iran

    Directory of Open Access Journals (Sweden)

    M Momeni

    2013-04-01

    Full Text Available Occupational exposure to cytotoxic drugs is a global concern. We conducted this cross-sectional study in 2012 to describe the adverse effects experienced by nurses working in one of chemotherapy facilities affiliated to Shiraz University of Medical Sciences, Shiraz, southern Iran, and their proper use of personal protective equipment and educational programs. The frequency of side effects reported by participants was noticeably high. Approximately, 60% of the nurses used all personal protective equipment. There were air conditioner ventilation systems in all facilities, but they were not standard. Clinics did not have any dedicated room. Lack of adequate training was noticeable among all participants. We concluded that establishment of safety regulations, health care workers safety surveillance systems as well as continuous training for nurses are of paramount importance.

  5. Comparison of direct measurement methods for headset noise exposure in the workplace

    Directory of Open Access Journals (Sweden)

    Flora G Nassrallah

    2016-01-01

    Full Text Available The measurement of noise exposure from communication headsets poses a methodological challenge. Although several standards describe methods for general noise measurements in occupational settings, these are not directly applicable to noise assessments under communication headsets. For measurements under occluded ears, specialized methods have been specified by the International Standards Organization (ISO 11904 such as the microphone in a real ear and manikin techniques. Simpler methods have also been proposed in some national standards such as the use of general purpose artificial ears and simulators in conjunction with single number corrections to convert measurements to the equivalent diffuse field. However, little is known about the measurement agreement between these various methods and the acoustic manikin technique. Twelve experts positioned circum-aural, supra-aural and insert communication headsets on four different measurement setups (Type 1, Type 2, Type 3.3 artificial ears, and acoustic manikin. Fit-refit measurements of four audio communication signals were taken under quiet laboratory conditions. Data were transformed into equivalent diffuse-field sound levels using third-octave procedures. Results indicate that the Type 1 artificial ear is not suited for the measurement of sound exposure under communication headsets, while Type 2 and Type 3.3 artificial ears are in good agreement with the acoustic manikin technique. Single number corrections were found to introduce a large measurement uncertainty, making the use of the third-octave transformation preferable.

  6. Radiofrequency protection guidelines and standards: basic concepts and principles

    International Nuclear Information System (INIS)

    Czerski, P.

    1985-01-01

    Over the past quarter of a century, radiofrequency radiation protection guidelines and standards evolved gradually and are continuously revised and refined. The scientific rationales presented for proposed exposure limits are achieving a considerable scientific sophistication. With increasing scientific validity of the presented arguments, the values of exposure limits are converging and one may hope that they will become convincing and acceptable to all schools of thought. Still more research is needed to refine the available exposure limits. This is recognized by ANSI who revise their recommendations periodically and are now engaged in the preparation of the next revision. INIRC/IRPA is also reconsidering their interim guideline. The Australian Standards Association also stressed the temporary nature of their exposure limits

  7. It's time to set some standards: Environmental classification of freshwater wetlands in New Zealand and their protection from eutrophication

    DEFF Research Database (Denmark)

    Sorrell, Brian Keith; Clarkson, Beverly

    Most natural resource plans provide protection for lakes and rivers from catchment activities leading to eutrophication. However, they are often silent about wetlands, due to the lack of information available for setting standards, defining reference conditions, and predicting responses to nutrient...... states in New Zealand wetlands, present an environmental classification based on physico-chemical and nutrient data, compare wetlands in New Zealand with those in other temperate regions, and argue for some catchment land use standards to protect wetlands from nutrient enrichment. Our database reveals...... that New Zealand wetlands, like those in other temperate climates, are defined by specific alkalinity and nutrient gradients and that there is a wide range of fertility levels. Using regression tree analysis, we have identified environmental groups of wetlands with significantly distinct nutrient regimes...

  8. Maternal Exposure to Bisphenol-A and Fetal Growth Restriction: A Case-Referent Study

    Directory of Open Access Journals (Sweden)

    Igor Burstyn

    2013-12-01

    Full Text Available We conducted a case-referent study of the effect of exposure to bisphenol-A on fetal growth in utero in full-term, live-born singletons in Alberta, Canada. Newborns <10 percentile of expected weight for gestational age and sex were individually matched on sex, maternal smoking and maternal age to referents with weight appropriate to gestational age. Exposure of the fetus to bisphenol-A was estimated from maternal serum collected at 15–16 weeks of gestation. We pooled sera across subjects for exposure assessment, stratified on case-referent status and sex. Individual 1:1 matching was maintained in assembling 69 case and 69 referent pools created from 550 case-referent pairs. Matched pools had an equal number of aliquots from individual women. We used an analytical strategy conditioning on matched set and total pool-level values of covariates to estimate individual-level effects. Pools of cases and referents had identical geometric mean bisphenol-A concentrations (0.5 ng/mL and similar geometric standard deviations (2.3–2.5. Mean difference in concentration between matched pools was 0 ng/mL, standard deviation: 1 ng/mL. Stratification by sex and control for confounding did not suggest bisphenol-A increased fetal growth restriction. Our analysis does not provide evidence to support the hypothesis that bisphenol-A contributes to fetal growth restriction in full-term singletons.

  9. Accounting for both local aquatic community composition and bioavailability in setting site-specific quality standards for zinc.

    Science.gov (United States)

    Peters, Adam; Simpson, Peter; Moccia, Alessandra

    2014-01-01

    Recent years have seen considerable improvement in water quality standards (QS) for metals by taking account of the effect of local water chemistry conditions on their bioavailability. We describe preliminary efforts to further refine water quality standards, by taking account of the composition of the local ecological community (the ultimate protection objective) in addition to bioavailability. Relevance of QS to the local ecological community is critical as it is important to minimise instances where quality classification using QS does not reconcile with a quality classification based on an assessment of the composition of the local ecology (e.g. using benthic macroinvertebrate quality assessment metrics such as River InVertebrate Prediction and Classification System (RIVPACS)), particularly where ecology is assessed to be at good or better status, whilst chemical quality is determined to be failing relevant standards. The alternative approach outlined here describes a method to derive a site-specific species sensitivity distribution (SSD) based on the ecological community which is expected to be present at the site in the absence of anthropogenic pressures (reference conditions). The method combines a conventional laboratory ecotoxicity dataset normalised for bioavailability with field measurements of the response of benthic macroinvertebrate abundance to chemical exposure. Site-specific QSref are then derived from the 5%ile of this SSD. Using this method, site QSref have been derived for zinc in an area impacted by historic mining activities. Application of QSref can result in greater agreement between chemical and ecological metrics of environmental quality compared with the use of either conventional (QScon) or bioavailability-based QS (QSbio). In addition to zinc, the approach is likely to be applicable to other metals and possibly other types of chemical stressors (e.g. pesticides). However, the methodology for deriving site-specific targets requires

  10. Nanotoxicity: emerging concerns regarding nanomaterial safety and occupational hard metal (WC-Co) nanoparticle exposure.

    Science.gov (United States)

    Armstead, Andrea L; Li, Bingyun

    As the number of commercial and consumer products containing engineered nanomaterials (ENMs) continually rises, the increased use and production of these ENMs presents an important toxicological concern. Although ENMs offer a number of advantages over traditional materials, their extremely small size and associated characteristics may also greatly enhance their toxic potentials. ENM exposure can occur in various consumer and industrial settings through inhalation, ingestion, or dermal routes. Although the importance of accurate ENM characterization, effective dosage metrics, and selection of appropriate cell or animal-based models are universally agreed upon as important factors in ENM research, at present, there is no "standardized" approach used to assess ENM toxicity in the research community. Of particular interest is occupational exposure to tungsten carbide cobalt (WC-Co) "dusts," composed of nano- and micro-sized particles, in hard metal manufacturing facilities and mining and drilling industries. Inhalation of WC-Co dust is known to cause "hard metal lung disease" and an increased risk of lung cancer; however, the mechanisms underlying WC-Co toxicity, the inflammatory disease state and progression to cancer are poorly understood. Herein, a discussion of ENM toxicity is followed by a review of the known literature regarding the effects of WC-Co particle exposure. The risk of WC-Co exposure in occupational settings and the updates of in vitro and in vivo studies of both micro- and nano-WC-Co particles are discussed.

  11. 7 CFR 225.17 - Procurement standards.

    Science.gov (United States)

    2010-01-01

    ...) Procurements by public sponsors comply with applicable State or local laws and the standards set forth in 7 CFR part 3016; and (2) Procurements by private nonprofit sponsors comply with standards set forth in 7 CFR... 7 Agriculture 4 2010-01-01 2010-01-01 false Procurement standards. 225.17 Section 225.17...

  12. A review of automatic exposure control of conventional and digital systems

    International Nuclear Information System (INIS)

    Workman, A.; Cowen, A.R.

    1989-01-01

    The desirable properties and methods of achieving automatic exposure control in film-screen radiography, fluoroscopy, spot-film fluorography and cinefluorography are discussed. Advantages of certain methods in achieving optimum image quality for minimal patient exposure are considered. In digital subtraction fluorography (DSF) where relatively large exposure levels per image are used, proper set-up of exposure conditions is of particular importance. These systems require a high degree of stability in exposure to maintain a high level of image quality. We have developed test methods for monitoring the set-up and reproducibility of exposure levels in DSF. (author)

  13. ISO radiation protection standards

    International Nuclear Information System (INIS)

    Becker, K.; West, N.

    1981-01-01

    After a brief description of the International Organization for Standardization (ISO) and its Technical Committee (TC) 85 ''Nuclear Energy'', the work of its Sub-Committee (SC) 2 ''Radiation Protection'' is described in some detail. Several international standards on subjects closely related to radiation protection have already been published, for example ISO-361 (Basic radiation protection symbol), ISO-1757 (Photographic dosimeters), ISO-1758 and 1759 (Direct and indirect-reading pocket exposure meters), ISO-2889 (Sampling of airborne radioactive materials), ISO-4037 (X and gamma reference radiations for calibration) and ISO-4071 (Testing of exposure meters and dosimeters). TC 85/SC 2 has currently eight active Working Groups (WG) dealing with 14 standards projects, mostly in advanced stages, in such fields as neutron and beta reference radiations, and X and gamma radiations of high and low dose-rates and high energies for calibration purposes, reference radiations for surface contamination apparatus, ejection systems for gamma radiography apparatus, industrial and laboratory irradiators, lead shielding units, protective clothing, thermoluminescence dosemeters, radioelement gauges, and surface contamination and decontamination. (author)

  14. Air toxics regulatory issues facing urban settings

    Energy Technology Data Exchange (ETDEWEB)

    Olden, K.; Guthrie, J. [National Institute of Environmental Health Sciences, Research Triangle Park, NC (United States)

    1996-10-01

    Biomarker research does not exist in isolation. Its usefulness can only be realized when it is translated into prevention strategies to protect public health. In the context of air toxics, these prevention strategies begin with the development of regulatory standards derived from risk assessment schemes. The Clean Air Act Amendments of 1990 list 189 air toxics, including many volatile organics, metals, and pesticides. The National Institute of Environmental Health Sciences (NIEHS), through its affiliation with the National Toxicology Program, has generated toxicity and carcinogenicity data on more than 100 of these air toxics. The NIEHS extramural and intramural research portfolios support a variety of projects that develop and validate biomarkers for use in environmental health science and risk assessment. Biomarkers have a tremendous potential in the areas of regulating air toxics and protecting public health. Risk assessors need data provided by biomarkers of exposure, biomarkers of close/pharmacokinetics, biomarkers of susceptibility or individual variability, and biomarkers of effects. The greatest benefit would be realized if biomarkers could be employed in four areas of primary and secondary prevention. The first is the use of biomarkers to enhance extrapolation of animal data to human exposure situations in establishing risk standards. The second is the use of biomarkers that assess noncancer, as well as cancer, end points. Important health end points include pulmonary dysfunction, immunotoxicity, and neurotoxicity. Third, biomarkers that serve as early warning signs to detect intermediate effects would enhance our ability to design timely and cost-effective intervention strategies. Finally, biomarkers used to evaluate the effectiveness of intervention strategies both in clinical and regulatory settings, would enable us to ensure that programs designed to protect public health do, in fact, achieve the desired outcome. 9 refs., 2 tabs.

  15. The Effect of Uncertainty in Exposure Estimation on the Exposure-Response Relation between 1,3-Butadiene and Leukemia

    Directory of Open Access Journals (Sweden)

    George Maldonado

    2009-09-01

    Full Text Available Abstract: In a follow-up study of mortality among North American synthetic rubber industry workers, cumulative exposure to 1,3-butadiene was positively associated with leukemia. Problems with historical exposure estimation, however, may have distorted the association. To evaluate the impact of potential inaccuracies in exposure estimation, we conducted uncertainty analyses of the relation between cumulative exposure to butadiene and leukemia. We created the 1,000 sets of butadiene estimates using job-exposure matrices consisting of exposure values that corresponded to randomly selected percentiles of the approximate probability distribution of plant-, work area/job group-, and year specific butadiene ppm. We then analyzed the relation between cumulative exposure to butadiene and leukemia for each of the 1,000 sets of butadiene estimates. In the uncertainty analysis, the point estimate of the RR for the first non zero exposure category (>0–<37.5 ppm-years was most likely to be about 1.5. The rate ratio for the second exposure category (37.5–<184.7 ppm-years was most likely to range from 1.5 to 1.8. The RR for category 3 of exposure (184.7–<425.0 ppm-years was most likely between 2.1 and 3.0. The RR for the highest exposure category (425.0+ ppm-years was likely to be between 2.9 and 3.7. This range off RR point estimates can best be interpreted as a probability distribution that describes our uncertainty in RR point estimates due to uncertainty in exposure estimation. After considering the complete probability distributions of butadiene exposure estimates, the exposure-response association of butadiene and leukemia was maintained. This exercise was a unique example of how uncertainty analyses can be used to investigate and support an observed measure of effect when occupational exposure estimates are employed in the absence of direct exposure measurements.

  16. Sensor-triggered sampling to determine instantaneous airborne vapor exposure concentrations.

    Science.gov (United States)

    Smith, Philip A; Simmons, Michael K; Toone, Phillip

    2018-06-01

    It is difficult to measure transient airborne exposure peaks by means of integrated sampling for organic chemical vapors, even with very short-duration sampling. Selection of an appropriate time to measure an exposure peak through integrated sampling is problematic, and short-duration time-weighted average (TWA) values obtained with integrated sampling are not likely to accurately determine actual peak concentrations attained when concentrations fluctuate rapidly. Laboratory analysis for integrated exposure samples is preferred from a certainty standpoint over results derived in the field from a sensor, as a sensor user typically must overcome specificity issues and a number of potential interfering factors to obtain similarly reliable data. However, sensors are currently needed to measure intra-exposure period concentration variations (i.e., exposure peaks). In this article, the digitized signal from a photoionization detector (PID) sensor triggered collection of whole-air samples when toluene or trichloroethylene vapors attained pre-determined levels in a laboratory atmosphere generation system. Analysis by gas chromatography-mass spectrometry of whole-air samples (with both 37 and 80% relative humidity) collected using the triggering mechanism with rapidly increasing vapor concentrations showed good agreement with the triggering set point values. Whole-air samples (80% relative humidity) in canisters demonstrated acceptable 17-day storage recoveries, and acceptable precision and bias were obtained. The ability to determine exceedance of a ceiling or peak exposure standard by laboratory analysis of an instantaneously collected sample, and to simultaneously provide a calibration point to verify the correct operation of a sensor was demonstrated. This latter detail may increase the confidence in reliability of sensor data obtained across an entire exposure period.

  17. Consistency endangered by FASB-GASB (Financial Accounting Standards Board, Government Accounting Standards Board ) dispute.

    Science.gov (United States)

    Garner, M; Grossman, W

    1991-02-01

    The Financial Accounting Foundation's (FAF's) November 1989 decision to uphold the 1984 jurisdictional arrangement between the Financial Accounting Standards Board (FASB) and the Government Accounting Standards Board (GASB) leaves little doubt that the healthcare industry will now be subject to two sets of accounting standards. The FAF's decision created a distinction between the accounting practices of government-owned hospitals and non-hospital governmental entities and their adherence to standards set by FASB, GASB, and the American Institute of Certified Public Accountants. A governmental healthcare organization should carefully determine which accounting rules it follows and remain attentive to further GASB developments.

  18. Nasa-wide Standard Administrative Systems

    Science.gov (United States)

    Schneck, P.

    1984-01-01

    Factors to be considered in developing agency-wide standard administrative systems for NASA include uniformity of hardware and software; centralization vs. decentralization; risk exposure; and models for software development.

  19. Trust, but Verify: Standard Setting That Honors and Validates Professional Teacher Judgment. Subtitle: A Tenuous Titanic Tale of Testy Testing and Titillating Touchstones (A Screen Play with an Unknown Number of Acts).

    Science.gov (United States)

    Matter, M. Kevin

    The Cherry Creek School district (Englewood, Colorado) is a growing district of 37,000 students in the Denver area. The 1988 Colorado State School Finance Act required district-set proficiencies (standards), and forced agreement on a set of values for student knowledge and skills. State-adopted standards added additional requirements for the…

  20. Standard test method for determining the susceptibility to intergranular corrosion of 5XXX series Aluminum alloys by mass loss after exposure to nitric acid (NAMLT Test)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This test method describes a procedure for constant immersion intergranular corrosion testing of 5XXX series aluminum alloys. 1.2 This test method is applicable only to wrought products. 1.3 This test method covers type of specimen, specimen preparation, test environment, and method of exposure. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  1. Nanostructured and nanolayer coatings based on nitrides of the metals structure study and structure and composition standard samples set development

    Directory of Open Access Journals (Sweden)

    E. B. Chabina

    2014-01-01

    Full Text Available Researches by methods of analytical microscopy and the x-ray analysis have allowed to develop a set of standard samples of composition and structure of the strengthening nanostructured and nanolayer coatings for control of the strengthening nanostructured and nanolayer coatings based on nitrides of the metals used to protect critical parts of the compressor of the gas turbine engine from dust erosion, corrosion and oxidation.

  2. A margin-of-exposure approach to assessment of noncancer risks of dioxins based on human exposure and response data.

    Science.gov (United States)

    Aylward, Lesa L; Goodman, Julie E; Charnley, Gail; Rhomberg, Lorenz R

    2008-10-01

    Risk assessment of human environmental exposure to polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/PCDFs) and other dioxin-like compounds is complicated by several factors, including limitations in measuring intakes because of the low concentrations of these compounds in foods and the environment and interspecies differences in pharmacokinetics and responses. We examined the feasibility of relying directly on human studies of exposure and potential responses to PCDD/PCDFs and related compounds in terms of measured lipid-adjusted concentrations to assess margin of exposure (MOE) in a quantitative, benchmark dose (BMD)-based framework using representative exposure and selected response data sets. We characterize estimated central tendency and upper-bound general U.S. population lipid-adjusted concentrations of PCDD/PCDFs from the 1970s and early 2000s based on available data sets. Estimates of benchmark concentrations for three example responses of interest (induction of cytochrome P4501A2 activity, dental anomalies, and neonatal thyroid hormone alterations) were derived based on selected human studies. The exposure data sets indicate that current serum lipid concentrations in young adults are approximately 6- to 7-fold lower than 1970s-era concentrations. Estimated MOEs for each end point based on current serum lipid concentrations range from 100 for dental anomalies-approximately 6-fold greater than would have existed during the 1970s. Human studies of dioxin exposure and outcomes can be used in a BMD framework for quantitative assessments of MOE. Incomplete exposure characterization can complicate the use of such studies in a BMD framework.

  3. Radiation Exposure of Interventional Radiologists During Computed Tomography Fluoroscopy-Guided Renal Cryoablation and Lung Radiofrequency Ablation: Direct Measurement in a Clinical Setting

    Energy Technology Data Exchange (ETDEWEB)

    Matsui, Yusuke, E-mail: wckyh140@yahoo.co.jp; Hiraki, Takao, E-mail: takaoh@tc4.so-net.ne.jp; Gobara, Hideo, E-mail: gobara@cc.okayama-u.ac.jp; Iguchi, Toshihiro, E-mail: i10476@yahoo.co.jp; Fujiwara, Hiroyasu, E-mail: hirofujiwar@gmail.com; Kawabata, Takahiro, E-mail: tkhr-kwbt@yahoo.co.jp [Okayama University Medical School, Department of Radiology (Japan); Yamauchi, Takatsugu, E-mail: me9248@hp.okayama-u.ac.jp; Yamaguchi, Takuya, E-mail: me8738@hp.okayama-u.ac.jp [Okayama University Hospital, Central Division of Radiology (Japan); Kanazawa, Susumu, E-mail: susumu@cc.okayama-u.ac.jp [Okayama University Medical School, Department of Radiology (Japan)

    2016-06-15

    IntroductionComputed tomography (CT) fluoroscopy-guided renal cryoablation and lung radiofrequency ablation (RFA) have received increasing attention as promising cancer therapies. Although radiation exposure of interventional radiologists during these procedures is an important concern, data on operator exposure are lacking.Materials and MethodsRadiation dose to interventional radiologists during CT fluoroscopy-guided renal cryoablation (n = 20) and lung RFA (n = 20) was measured prospectively in a clinical setting. Effective dose to the operator was calculated from the 1-cm dose equivalent measured on the neck outside the lead apron, and on the left chest inside the lead apron, using electronic dosimeters. Equivalent dose to the operator’s finger skin was measured using thermoluminescent dosimeter rings.ResultsThe mean (median) effective dose to the operator per procedure was 6.05 (4.52) μSv during renal cryoablation and 0.74 (0.55) μSv during lung RFA. The mean (median) equivalent dose to the operator’s finger skin per procedure was 2.1 (2.1) mSv during renal cryoablation, and 0.3 (0.3) mSv during lung RFA.ConclusionRadiation dose to interventional radiologists during renal cryoablation and lung RFA were at an acceptable level, and in line with recommended dose limits for occupational radiation exposure.

  4. Radiation Exposure of Interventional Radiologists During Computed Tomography Fluoroscopy-Guided Renal Cryoablation and Lung Radiofrequency Ablation: Direct Measurement in a Clinical Setting.

    Science.gov (United States)

    Matsui, Yusuke; Hiraki, Takao; Gobara, Hideo; Iguchi, Toshihiro; Fujiwara, Hiroyasu; Kawabata, Takahiro; Yamauchi, Takatsugu; Yamaguchi, Takuya; Kanazawa, Susumu

    2016-06-01

    Computed tomography (CT) fluoroscopy-guided renal cryoablation and lung radiofrequency ablation (RFA) have received increasing attention as promising cancer therapies. Although radiation exposure of interventional radiologists during these procedures is an important concern, data on operator exposure are lacking. Radiation dose to interventional radiologists during CT fluoroscopy-guided renal cryoablation (n = 20) and lung RFA (n = 20) was measured prospectively in a clinical setting. Effective dose to the operator was calculated from the 1-cm dose equivalent measured on the neck outside the lead apron, and on the left chest inside the lead apron, using electronic dosimeters. Equivalent dose to the operator's finger skin was measured using thermoluminescent dosimeter rings. The mean (median) effective dose to the operator per procedure was 6.05 (4.52) μSv during renal cryoablation and 0.74 (0.55) μSv during lung RFA. The mean (median) equivalent dose to the operator's finger skin per procedure was 2.1 (2.1) mSv during renal cryoablation, and 0.3 (0.3) mSv during lung RFA. Radiation dose to interventional radiologists during renal cryoablation and lung RFA were at an acceptable level, and in line with recommended dose limits for occupational radiation exposure.

  5. Exposure pathways and health effects associated with chemical and radiological toxicity of natural uranium: a review.

    Science.gov (United States)

    Brugge, Doug; de Lemos, Jamie L; Oldmixon, Beth

    2005-01-01

    Natural uranium exposure derives from the mining, milling, and processing of uranium ore, as well as from ingestion of groundwater that is naturally contaminated with uranium. Ingestion and inhalation are the primary routes of entry into the body. Absorption of uranium from the lungs or digestive track is typically low but can vary depending on compound specific solubility. From the blood, two-thirds of the uranium is excreted in urine over the first 24 hours and up to 80% to 90% of uranium deposited in the bone leaves the body within 1.5 years. The primary health outcomes of concern documented with respect to uranium are renal, developmental, reproductive, diminished bone growth, and DNA damage. The reported health effects derive from experimental animal studies and human epidemiology. The Lowest Observed Adverse Effect Level (LOAEL) derived from animal studies is 50 microg/m3 for inhalation and 60 ug/kg body weight/day for ingestion. The current respiratory standard of the Occupational Safety and Health Administration (OSHA), 50 microg/m3, affords no margin of safety. Considering the safety factors for species and individual variation, the ingestion LOAEL corresponds to the daily consumption set by the World Health Organization Drinking Water Standard at 2 microg/L. Based on economic considerations, the United States Environmental Protection Agency maximum contaminant level is 30 microg/L. Further research is needed, with particular attention on the impact of uranium on indigenous populations, on routes of exposure in communities near uranium sites, on the combined exposures present at many uranium sites, on human developmental defects, and on health effects at or below established exposure standards.

  6. Nanoparticle exposure biomonitoring: exposure/effect indicator development approaches

    Science.gov (United States)

    Marie-Desvergne, C.; Dubosson, M.; Lacombe, M.; Brun, V.; Mossuz, V.

    2015-05-01

    The use of engineered nanoparticles (NP) is more and more widespread in various industrial sectors. The inhalation route of exposure is a matter of concern (adverse effects of air pollution by ultrafine particles and asbestos). No NP biomonitoring recommendations or standards are available so far. The LBM laboratory is currently studying several approaches to develop bioindicators for occupational health applications. As regards exposure indicators, new tools are being implemented to assess potentially inhaled NP in non-invasive respiratory sampling (nasal sampling and exhaled breath condensates (EBC)). Diverse NP analytical characterization methods are used (ICP-MS, dynamic light scattering and electron microscopy coupled to energy-dispersive X-ray analysis). As regards effect indicators, a methodology has been developed to assess a range of 29 cytokines in EBCs (potential respiratory inflammation due to NP exposure). Secondly, collaboration between the LBM laboratory and the EDyp team has allowed the EBC proteome to be characterized by means of an LC-MS/MS process. These projects are expected to facilitate the development of individual NP exposure biomonitoring tools and the analysis of early potential impacts on health. Innovative techniques such as field-flow fractionation combined with ICP-MS and single particle-ICPMS are currently being explored. These tools are directly intended to assist occupational physicians in the identification of exposure situations.

  7. Nanoparticle exposure biomonitoring: exposure/effect indicator development approaches

    International Nuclear Information System (INIS)

    Marie-Desvergne, C; Dubosson, M; Mossuz, V; Lacombe, M; Brun, V

    2015-01-01

    The use of engineered nanoparticles (NP) is more and more widespread in various industrial sectors. The inhalation route of exposure is a matter of concern (adverse effects of air pollution by ultrafine particles and asbestos). No NP biomonitoring recommendations or standards are available so far. The LBM laboratory is currently studying several approaches to develop bioindicators for occupational health applications. As regards exposure indicators, new tools are being implemented to assess potentially inhaled NP in non-invasive respiratory sampling (nasal sampling and exhaled breath condensates (EBC)). Diverse NP analytical characterization methods are used (ICP-MS, dynamic light scattering and electron microscopy coupled to energy-dispersive X-ray analysis). As regards effect indicators, a methodology has been developed to assess a range of 29 cytokines in EBCs (potential respiratory inflammation due to NP exposure). Secondly, collaboration between the LBM laboratory and the EDyp team has allowed the EBC proteome to be characterized by means of an LC-MS/MS process. These projects are expected to facilitate the development of individual NP exposure biomonitoring tools and the analysis of early potential impacts on health. Innovative techniques such as field-flow fractionation combined with ICP-MS and single particle-ICPMS are currently being explored. These tools are directly intended to assist occupational physicians in the identification of exposure situations. (paper)

  8. Exposure of bakery and pastry apprentices to airborne flour dust using PM2.5 and PM10 personal samplers.

    Science.gov (United States)

    Mounier-Geyssant, Estelle; Barthélemy, Jean-François; Mouchot, Lory; Paris, Christophe; Zmirou-Navier, Denis

    2007-11-01

    This study describes exposure levels of bakery and pastry apprentices to flour dust, a known risk factor of occupational asthma. Questionnaires on work activity were completed by 286 students. Among them, 34 performed a series of two personal exposure measurements using a PM2.5 and PM10 personal sampler during a complete work shift, one during a cold ("winter") period, and the other during a hot ("summer") period. Bakery apprentices experience greater average PM2.5 and PM10 exposures than pastry apprentices (p < 0.006). Exposure values for both particulate fractions are greater in winter (average PM10 values among bakers = 1.10 mg.m-3 [standard deviation: 0.83]) than in summer (0.63 mg.m-3 [0.36]). While complying with current European occupational limit values, these exposures exceed the ACGIH recommendations set to prevent sensitization to flour dust (0.5 mg.m-3). Over half the facilities had no ventilation system. Young bakery apprentices incur substantial exposure to known airways allergens, a situation that might elicit early induction of airways inflammation.

  9. Quality of semantic standards

    NARCIS (Netherlands)

    Folmer, Erwin Johan Albert

    2012-01-01

    Little scientific literature addresses the issue of quality of semantic standards, albeit a problem with high economic and social impact. Our problem survey, including 34 semantic Standard Setting Organizations (SSOs), gives evidence that quality of standards can be improved, but for improvement a

  10. Low-cost matched sibling bone marrow transplant for standard-risk thalassemia in a limited-resource setting

    Directory of Open Access Journals (Sweden)

    Stalin Ramprakash

    2017-12-01

    Full Text Available Thalassemias are the most common inherited genetic disorder in India and a major public health burden with bone marrow transplant (BMT considered the only established curative therapy. We describe outcomes for patients (n = 71 with standard-risk thalassemia (liver size 80 at the last follow up. 5 patients (7% died, mortality related to transplant. Enough data existed for 2 centers in India (36/71 transplants to analyze overall costs from admission up to one-year post-BMT which revealed a median cost of Rs 7,30,445 ($11519 [Range Rs 4,52,821–10,32,842 ($ 7079–16147]. In conclusion, children with thalassemia in resource limited settings can achieve good outcomes with BMT at a reasonable cost.

  11. Standardization of a geo-referenced fishing data set for the Indian Ocean bigeye tuna, Thunnus obesus (1952-2014)

    Science.gov (United States)

    Wibawa, Teja A.; Lehodey, Patrick; Senina, Inna

    2017-02-01

    Geo-referenced catch and fishing effort data of the bigeye tuna fisheries in the Indian Ocean over 1952-2014 were analyzed and standardized to facilitate population dynamics modeling studies. During this 62-year historical period of exploitation, many changes occurred both in the fishing techniques and the monitoring of activity. This study includes a series of processing steps used for standardization of spatial resolution, conversion and standardization of catch and effort units, raising of geo-referenced catch into nominal catch level, screening and correction of outliers, and detection of major catchability changes over long time series of fishing data, i.e., the Japanese longline fleet operating in the tropical Indian Ocean. A total of 30 fisheries were finally determined from longline, purse seine and other-gears data sets, from which 10 longline and 4 purse seine fisheries represented 96 % of the whole historical geo-referenced catch. Nevertheless, one-third of total nominal catch is still not included due to a total lack of geo-referenced information and would need to be processed separately, accordingly to the requirements of the study. The geo-referenced records of catch, fishing effort and associated length frequency samples of all fisheries are available at PANGAEA.864154" target="_blank">doi:10.1594/PANGAEA.864154.

  12. Maternal Exposure to Bisphenol-A and Fetal Growth Restriction: A Case-Referent Study

    Science.gov (United States)

    Burstyn, Igor; Martin, Jonathan W.; Beesoon, Sanjay; Bamforth, Fiona; Li, Qiaozhi; Yasui, Yutaka; Cherry, Nicola M.

    2013-01-01

    We conducted a case-referent study of the effect of exposure to bisphenol-A on fetal growth in utero in full-term, live-born singletons in Alberta, Canada. Newborns bisphenol-A was estimated from maternal serum collected at 15–16 weeks of gestation. We pooled sera across subjects for exposure assessment, stratified on case-referent status and sex. Individual 1:1 matching was maintained in assembling 69 case and 69 referent pools created from 550 case-referent pairs. Matched pools had an equal number of aliquots from individual women. We used an analytical strategy conditioning on matched set and total pool-level values of covariates to estimate individual-level effects. Pools of cases and referents had identical geometric mean bisphenol-A concentrations (0.5 ng/mL) and similar geometric standard deviations (2.3–2.5). Mean difference in concentration between matched pools was 0 ng/mL, standard deviation: 1 ng/mL. Stratification by sex and control for confounding did not suggest bisphenol-A increased fetal growth restriction. Our analysis does not provide evidence to support the hypothesis that bisphenol-A contributes to fetal growth restriction in full-term singletons. PMID:24336026

  13. Diversification and Challenges of Software Engineering Standards

    Science.gov (United States)

    Poon, Peter T.

    1994-01-01

    The author poses certain questions in this paper: 'In the future, should there be just one software engineering standards set? If so, how can we work towards that goal? What are the challenges of internationalizing standards?' Based on the author's personal view, the statement of his position is as follows: 'There should NOT be just one set of software engineering standards in the future. At the same time, there should NOT be the proliferation of standards, and the number of sets of standards should be kept to a minimum.It is important to understand the diversification of the areas which are spanned by the software engineering standards.' The author goes on to describe the diversification of processes, the diversification in the national and international character of standards organizations, the diversification of the professional organizations producing standards, the diversification of the types of businesses and industries, and the challenges of internationalizing standards.

  14. Occupational radiation protection: Protecting workers against exposure to ionizing radiation. Contributed papers

    International Nuclear Information System (INIS)

    2003-07-01

    Occupational exposure to ionizing radiation can occur in a range of industries, mining and milling; medical institutions, educational and research establishments and nuclear fuel cycle facilities. The term 'occupational exposure' refers to the radiation exposure incurred by a worker, which is attributable to the worker's occupation and committed during a period of work. According to the latest (2000) Report of the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), an estimated 11 million workers are monitored for exposure to ionizing radiation. They incur radiation doses attributable to their occupation, which range from a small fraction of the global average background exposure to natural radiation up to several times that value. It should be noted that the UNSCEAR 2000 Report describes a downward trend in the exposure of several groups of workers, but it also indicates that occupational exposure is affecting an increasingly large group of people worldwide. The International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (BSS), which are co-sponsored by, inter alia, the International Atomic Energy Agency (IAEA), the International Labour Organization (ILO), the OECD Nuclear Energy Agency (NEA) and the World Health Organization (WHO), establish a system of radiation protection which includes radiation dose limits for occupational exposure. Guidance supporting the requirements of the BSS for occupational protection is provided in three interrelated Safety Guides, jointly sponsored by the IAEA and the ILO. These Guides describe, for example, the implications for employers in discharging their main responsibilities (such as setting up appropriate radiation protection programmes) and similarly for workers (such as properly using the radiation monitoring devices provided to them). The IAEA i organized its first International Conference on Occupational Radiation Protection. The

  15. Radiation exposures to technologists from nuclear medicine imaging procedures

    International Nuclear Information System (INIS)

    Sloboda, R.S.; Schmid, M.G.; Willis, C.P.

    1986-05-01

    Radiation exposures incurred by nuclear medicine technologists during diagnostic imaging and gamma camera quality control (QC) were measured on a procedural basis over a three-month period using a portable, low-range, self-reading ion chamber. A total of more than 400 measurements were made for 15 selected procedures. From these, mean procedural exposures and standard deviations were calculated. The results show that daily flood phantom QC, at 0.58 mR, and gated cardiac studies, at 0.45 mR, were the two greatest sources of exposure. Other procedures resulted in exposures varying roughly from 0.10 to 0.20 mR. Difficult patients were responsible for a doubling of technologist exposure for many procedures. Standard deviations were large for all procedures, averaging 65% of the mean values. Comparison of technologist exposure inferred from the procedural measurements with the time coincident collective dose equivalent recorded by the TLD service of the Radiation Protection Bureau indicates that approximately half of the collective technologist exposure arose from patient handling and flood QC

  16. Selected science: an industry campaign to undermine an OSHA hexavalent chromium standard

    Directory of Open Access Journals (Sweden)

    Lurie Peter

    2006-02-01

    Full Text Available Abstract While exposure to hexavalent chromium (Cr(VI has been associated with increased lung cancer risk for more than 50 years, the chemical is not currently regulated by the U.S. Occupational Safety and Health Administration (OSHA on the basis of its carcinogenicity. The agency was petitioned in 1993 and sued in 1997 and 2002 to lower the workplace Cr(VI exposure limit, resulting in a court order to issue a final standard by February 2006. Faced with the threat of stronger regulation, the chromium industry initiated an effort to challenge the scientific evidence supporting a more protective standard. This effort included the use of "product defense" consultants to conduct post hoc analyses of a publicly-funded study to challenge results viewed unfavorably by the industry. The industry also commissioned a study of the mortality experience of workers at four low-exposure chromium plants, but did not make the results available to OSHA in a timely manner, despite multiple agency requests for precisely these sorts of data. The commissioned study found a statistically significant elevation in lung cancer risk among Cr(VI-exposed workers at levels far below the current standard. This finding changed when the multi-plant cohort was divided into two statistically underpowered components and then published separately. The findings of the first paper published have been used by the chromium industry to attempt to slow OSHA's standard setting process. The second paper was withheld from OSHA until it was accepted for publication in a scientific journal, after the rulemaking record had closed. Studies funded by private sponsors that seek to influence public regulatory proceedings should be subject to the same access and reporting provisions as those applied to publicly funded science. Parties in regulatory proceedings should be required to disclose whether the studies were performed by researchers who had the right to present their findings without the

  17. CHALLENGES IN SETTING UP QUALITY CONTROL IN DIAGNOSTIC RADIOLOGY FACILITIES IN NIGERIA.

    Science.gov (United States)

    Inyang, S O; Egbe, N O; Ekpo, E

    2015-01-01

    The Nigerian Nuclear Regulatory Authority (NNRA) was established to regulate and control the use of radioactive and radiation emitting sources in Nigeria. Quality control (QC) on diagnostic radiology equipment form part of the fundamental requirements for the authorization of diagnostic radiology facilities in the Country. Some quality control tests (output, exposure linearity and reproducibility) were measured on the x-ray machines in the facilities that took part in the study. Questionnaire was developed to evaluate the frequencies at which QC tests were conducted in the facilities and the challenges in setting up QC. Results show great variation in the values of the QC parameters measured. Inadequate cooperation by facilities management, lack of QC equipment and insufficient staff form the major challenges in setting up QC in the facilities under study. The responses on the frequencies at which QC tests should be conducted did not correspond to the recommended standards; indicating that personnel were not familiar with QC implementation and may require further training on QC.

  18. Standard Practice for Visual Inspections of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This practice covers procedures and criteria for visual inspections of photovoltaic modules. 1.2 Visual inspections of photovoltaic modules are normally performed before and after modules have been subjected to environmental, electrical, or mechanical stress testing, such as thermal cycling, humidity-freeze cycling, damp heat exposure, ultraviolet exposure, mechanical loading, hail impact testing, outdoor exposure, or other stress testing that may be part of photovoltaic module testing sequence. 1.3 This practice does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this practice. 1.4 There is no similar or equivalent ISO standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. Proposals for changes in radiation protection standards

    International Nuclear Information System (INIS)

    Bowker, K.W.

    1990-01-01

    The International Commission on Radiological Protection has proposed changes to its recommendations on radiation protection standards. The proposed new control regime would distinguish between planned, potential and pre-existing exposure situations and between occupational, medical and public exposures. The proposals are expected to be published formally later this year. (author)

  20. USEPA consideration of human intrusion in setting radioactive waste disposal standards

    International Nuclear Information System (INIS)

    Egan, D.J.; Hadlock, C.R.

    1989-01-01

    In 1985, the United States Environmental Protection Agency (USEPA) promulgated standards for the disposal of spent nuclear fuel and high-level and transuranic radioactive wastes (40 CFR Part 191). These standards placed limits, called containment requirements, on the projected releases of radioactivity due to both normal and accidental events for 10,000 years after disposal. The standards also contained qualitative assurance requirements that described the role foreseen for both active and passive institutional controls. They included both requirements for such institutional controls and limitations on the ways that they could be relied upon. This paper describes these assumptions about institutional controls made by the USEPA, and it discusses the types of future societies that would be consistent with such assumptions. The paper also reviews the USEPA's approach towards assessing the long-term performance of mined geologic repositories. In these assessments, the risks caused by inadvertent human intrusion into the area of a repository usually dominate the risks projected from other release scenarios. The assumptions made about inadvertent intrusion are discussed, and they are related to the policies regarding institutional controls. The disposal standards that the USEPA promulgated in 1985 were overturned by a Federal court in 1987, and the Agency is now preparing revised standards for public review and comment. These are expected to by published in 1990. However, the approaches regarding institutional controls and human intrusion are expected to remain the same as those used in 1985. Some paragraphs (selected by the NEA Secretariat) of 40 CFR Part 191, subpart B (as of 1985 version) with particular relevance to human intrusion are cited

  1. The ACT/NAGB Standard Setting Process: How "Modified" Does It Have To Be before It Is No Longer a Modified-Angoff Process?

    Science.gov (United States)

    Reckase, Mark D.

    The kernel of the Angoff method of standard setting (W. Angoff, 1971) would seem to be the judgment of whether a minimally competent person could answer an item on a test correctly or not. So it would seem that any procedure that requires independent judgment of the correctness or incorrectness of a response to items for a minimally acceptable…

  2. Aluminium sulfate exposure: A set of effects on hydrolases from brain, muscle and digestive tract of juvenile Nile tilapia (Oreochromis niloticus).

    Science.gov (United States)

    Oliveira, Vagne Melo; Assis, Caio Rodrigo Dias; Costa, Helane Maria Silva; Silva, Raquel Pereira Freitas; Santos, Juliana Ferreira; Carvalho, Luiz Bezerra; Bezerra, Ranilson Souza

    2017-01-01

    Aluminium is a major pollutant due to its constant disposal in aquatic environments through anthropogenic activities. The physiological effects of this metal in fish are still scarce in the literature. This study investigated the in vivo and in vitro effects of aluminium sulfate on the activity of enzymes from Nile tilapia (Oreochromis niloticus): brain acetylcholinesterase (AChE), muscle cholinesterases (AChE-like and BChE-like activities), pepsin, trypsin, chymotrypsin and amylase. Fish were in vivo exposed during 14days when the following experimental groups were assayed: control group (CG), exposure to Al 2 (SO 4 ) 3 at 1μg·mL -1 (G1) and 3μg·mL -1 (G3) (concentrations compatible with the use of aluminium sulfate as coagulant in water treatment). In vitro exposure was performed using animals of CG treatment. Both in vivo and in vitro exposure increased cholinesterase activity in relation to controls. The highest cholinesterase activity was observed for muscle BChE-like enzyme in G3. In contrast, the digestive enzymes showed decreased activity in both in vivo and in vitro exposures. The highest inhibitory effect was observed for pepsin activity. The inhibition of serine proteases was also quantitatively analyzed in zymograms using pixel optical densitometry as area under the peaks (AUP) and integrated density (ID). These results suggest that the inhibition of digestive enzymes in combination with activation of cholinesterases in O. niloticus is a set of biochemical effects that evidence the presence of aluminium in the aquatic environment. Moreover, these enzymatic alterations may support further studies on physiological changes in this species with implications for its neurological and digestive metabolisms. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Study on radiation dose in the medical image data display method-focus on the DICOM standard

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Su [Dept. of Radio-technology, Health Welfare, Wonkwang Health Science University, Iksan (Korea, Republic of)

    2015-12-15

    DICOM (Digital Imaging and Communications in Medicine) standards are generally introduced as de facto and de jure standards in modern medical imaging devices to store and to transmit medical image information. DICOM Dose Structured Report (DICOM dose SR) is implemented to report radiation exposure information in image acquiring process. and DIOCM Modality Performed Procedure Step (DICOM MPPS) is also partly used to report this exposure with the information in its DICOM tag. This article is focused on three type of radiation exposure information of DICOM standards, 1) DICOM dose SR, 2) DICOM MPPS and 3) Radiation Exposure Monitoring(REM) profile by Integrating the Healthcare Enterprise(IHE), to study on radiation exposure reporting. Healthcare facility and its staff of medical imaging related to radiation exposure should have a deep understanding of radiation exposure, and it required a standards to enhance the quality control of medical imaging and the safety of patients and staffs. Staff member have to pay attention on radiation exposures and controlling processes from the purchasing stage of X-ray devices.

  4. Study on radiation dose in the medical image data display method-focus on the DICOM standard

    International Nuclear Information System (INIS)

    Kim, Jung Su

    2015-01-01

    DICOM (Digital Imaging and Communications in Medicine) standards are generally introduced as de facto and de jure standards in modern medical imaging devices to store and to transmit medical image information. DICOM Dose Structured Report (DICOM dose SR) is implemented to report radiation exposure information in image acquiring process. and DIOCM Modality Performed Procedure Step (DICOM MPPS) is also partly used to report this exposure with the information in its DICOM tag. This article is focused on three type of radiation exposure information of DICOM standards, 1) DICOM dose SR, 2) DICOM MPPS and 3) Radiation Exposure Monitoring(REM) profile by Integrating the Healthcare Enterprise(IHE), to study on radiation exposure reporting. Healthcare facility and its staff of medical imaging related to radiation exposure should have a deep understanding of radiation exposure, and it required a standards to enhance the quality control of medical imaging and the safety of patients and staffs. Staff member have to pay attention on radiation exposures and controlling processes from the purchasing stage of X-ray devices

  5. A study of exposure to RF radiation during MRI examinations. 2. A comparison of two procedures measuring the whole body SAR

    International Nuclear Information System (INIS)

    Yamada, Masayuki; Imaeda, Isao; Koga, Sukehiko; Sugie, Masami; Anno, Hirofumi; Kinoshita, Kazuo; Okada, Tatsuhiko; Endou, Yukio; Katada, Kazuhiro.

    1997-01-01

    The purpose of this study is to evaluate exposure to radiofrequency (RF) radiation during magnetic resonance imaging (MRI) examinations. Particularly, in this paper, the authors compared the measuring procedures of a whole body specific absorption rate (SAR) set forth in two safety guidelines respectively: the safety guideline of MRI equipments in Japan which based on the 1988 guideline of the Food and Drug Administration (FDA), and the 1995 standard of the International Electrotechnical Commission (IEC). As a result of the measurement, the measuring procedure set forth in the Japanese guideline underestimated the whole body SAR of a torso phantom in a tuneless type QD coil. The result of our experiment clearly showed that the measuring procedure set forth in the Japanese guideline did not adjust to the tuneless type QD coil. Therefore, the authors recommended ''the pulse energy method'' which is provided by the IEC standard as a measuring procedure of the whole body SAR. (author)

  6. Radiation exposure in diagnostic medicine

    International Nuclear Information System (INIS)

    Haehnel, S.; Michalczak, H.; Reinoehl-Kompa, S.

    1995-01-01

    This volume includes the manuscripts of the papers read at the conference as well as a summary and assessment of its results. The scientific discussions were centred upon the following issues: - International surveys and comparisons of rdiation exposures in diagnostic radiology and nuclear medicine, frequency of the individual diagnostic procedures and age distribution of patients examined; - policies and regulations for the radiation protection of patients, charcteristic dosimetric values and practical usefulness of the effective dose concept during medical examinations; - assessments of the relative benefits and risks and measures to reduce the radiation exposure in the light of quality assurance aspects. The main objective of this conference not only was to evaluate the risks from diagnostic radiology and nuclear medicine but also to encourgage a critical analysis and adjustment of examination routines followed in everyday practice. Among the measures recommended were quality assurance, maintenace of international standards, development of guidelines, introduction of standard doses, improved training and professional education of personnel as well as surveys and analyses of certain examination procedures associated with substantial radiation exposure. (orig./MG) [de

  7. The Australian Work Exposures Study: Prevalence of Occupational Exposure to Formaldehyde.

    Science.gov (United States)

    Driscoll, Timothy R; Carey, Renee N; Peters, Susan; Glass, Deborah C; Benke, Geza; Reid, Alison; Fritschi, Lin

    2016-01-01

    The aims of this study were to produce a population-based estimate of the prevalence of work-related exposure to formaldehyde, to identify the main circumstances of exposure and to describe the use of workplace control measures designed to decrease those exposures. The analysis used data from the Australian Workplace Exposures Study, a nationwide telephone survey, which investigated the current prevalence and exposure circumstances of work-related exposure to 38 known or suspected carcinogens, including formaldehyde, among Australian workers aged 18-65 years. Using the web-based tool OccIDEAS, semi-quantitative information was collected about exposures in the current job held by the respondent. Questions were addressed primarily at tasks undertaken rather than about self-reported exposures. Of the 4993 included respondents, 124 (2.5%) were identified as probably being exposed to formaldehyde in the course of their work [extrapolated to 2.6% of the Australian working population-265 000 (95% confidence interval 221 000-316 000) workers]. Most (87.1%) were male. About half worked in technical and trades occupations. In terms of industry, about half worked in the construction industry. The main circumstances of exposure were working with particle board or plywood typically through carpentry work, building maintenance, or sanding prior to painting; with the more common of other exposures circumstances being firefighters involved in fighting fires, fire overhaul, and clean-up or back-burning; and health workers using formaldehyde when sterilizing equipment or in a pathology laboratory setting. The use of control measures was inconsistent. Workers are exposed to formaldehyde in many different occupational circumstances. Information on the exposure circumstances can be used to support decisions on appropriate priorities for intervention and control of occupational exposure to formaldehyde, and estimates of burden of cancer arising from occupational exposure to formaldehyde

  8. A randomized controlled trial comparing customized versus standard headrests for head and neck radiotherapy immobilization in terms of set-up errors, patient comfort and staff satisfaction (ICORG 08-09)

    International Nuclear Information System (INIS)

    Howlin, C.; O'Shea, E.; Dunne, M.; Mullaney, L.; McGarry, M.; Clayton-Lea, A.; Finn, M.; Carter, P.; Garret, B.; Thirion, P.

    2015-01-01

    Purpose: To recommend a specific headrest, customized or standard, for head and neck radiotherapy patients in our institution based primarily on an evaluation of set-up accuracy, taking into account a comparison of patient comfort, staff and patient satisfaction, and resource implications. Methods and materials: Between 2008 and 2009, 40 head and neck patients were randomized to either a standard (Arm A, n = 21) or customized (Arm B, n = 19) headrest, and immobilized with a customized thermoplastic mask. Set-up accuracy was assessed using electronic portal images (EPI). Random and systematic set-up errors for each arm were determined from 668 EPIs, which were analyzed by one Radiation Therapist. Patient comfort was assessed using a visual analogue scale (VAS) and staff satisfaction was measured using an in-house questionnaire. Resource implications were also evaluated. Results: The difference in set-up errors between arms was not significant in any direction. However, in this study the standard headrest (SH) arm performed well, with set-up errors comparative to customized headrests (CHs) in previous studies. CHs require regular monitoring and 47% were re-vacuumed making them more resource intensive. Patient comfort and staff satisfaction were comparable in both arms. Conclusion: The SH provided similar treatment accuracy and patient comfort compared with the CH. The large number of CHs that needed to be re-vacuumed undermines their reliability for radiotherapy schedules that extend beyond 34 days from the initial CT scan. Accordingly the CH was more resource intensive without improving the accuracy of positioning, thus the standard headrest is recommended for continued use at our institution

  9. Setting a protective PM standard: A view from the frontline

    Energy Technology Data Exchange (ETDEWEB)

    John Paul; Eddie Terrill [Dayton Regional Air Pollution Control Agency, Dayton, OH (United States)

    2006-06-15

    Several aspects of the US EPA's recent proposal to revise the particulate matter (PM) standards deeply concern state and local air agencies and their representatives with the State and Territorial Air Pollution Program Administrators and the Association of Local Air Pollution Control Offices (STAPPA and ALAPCO). STAPPA and ALAPCO urge EPA to follow the recommendations of its appointed scientific experts and lower the annual average standard to 13 or 14 {mu}mg/m{sup 3} in addition to lowering the daily standard to 35 {mu}m/m{sup 3}. Unless EPA strengthens its proposal consistent with the recommendations of the Clean Air Scientific Advisory Committee (CASAC), STAPPA and ALAPCO are extremely concerned that we will continue to see significant increased premature mortality and adverse health effects throughout the country. For the reasons described in the article STAPPA and ALAPCO urge EPA to eliminate the exemptions for agriculture, mining and rural windblown dust. STAPPA and ALAPCO are troubled that EPA has ignored any commitment to funding the proposed coarse PM network scheduled for deployment in Fiscal Year (FY) 2008. EPA has estimated that the capital costs of this monitoring network could easily exceed US$ 14 million, with annual operating expenses of approximately US$ 13 million. State and local agencies will simply not be able to assume these significant costs. 33 refs.

  10. Advisory Committee for the calibration standards of ionizing radiation measurement

    International Nuclear Information System (INIS)

    1979-01-01

    The meeting consisted exceptionally of two sessions (in May and December 1977). The members discussed the comparisons of absorbed dose standards and exposure standards which had taken place since 1975 and suggested improvements for future comparisons. A recommendation was made concerning the humidity correction factor to be applied when using cavity chambers and free-air chambers. Further studies were requested concerning the effective point of measurement of ionization chambers. No method was recommended for the statement of uncertainty in calibration certificates. The exposure standards and calibrations in terms of exposure were maintained but it was agreed that other possibilities should be explored. Finally, progress reports of the national laboratories and a description of the recent work carried out at BIPM were presented and appear as appendices to the report [fr

  11. Common basis of establishing safety standards and other safety decision-making levels for different sources of health risk

    International Nuclear Information System (INIS)

    Demin, V.F.

    2002-01-01

    Current approaches in establishing safety standards and other decision-making levels for different sources of health risk are critically analysed. To have a common basis for this decision-making a specific risk index R is recommended. In the common sense R is quantitatively defined as LLE caused by the annual exposure to the risk source considered: R = annual exposure, damage (LLE) from the exposure unit. This common definition is also rewritten in specific forms for a set of different risk sources (ionising radiation, chemical pollutants, etc): for different risk sources the exposure can be measured with different quantities (the probability of death, the exposure dose, etc.). R is relative LLE: LLE in years referred to 1 year under the risk. The dimension of this value is [year/year]. In the statistical sense R is conditionally the share of the year, which is lost due to exposure to a risk source during this year. In this sense R can be called as the relative damage. Really lifetime years are lost after the exposure. R can be in some conditional sense considered as a dimensionless quantity. General safety standards R n for the public and occupational workers have been suggested in terms of this index: R n = 0.0007 and 0.01 accordingly. Secondary safety standards are derived for a number of risk sources (ionising radiation, environmental chemical pollutants, etc). Values of R n are chosen in such a way that to have the secondary radiation BSS being equivalent to the current one's. Other general and derived levels for safety decision-making are also proposed including the de-minimus levels. Their possible dependence on the national or regional health-demographic data (HDD) is considered. Such issues as the ways of the integration and averaging of risk indices considered through the national or regional HDD for different risk sources and the use of non-threshold linear exposure - response relationships for ionising radiation and chemical pollutants are analysed

  12. Health effects and risks of radon exposure

    International Nuclear Information System (INIS)

    Cross, F.T.

    1990-01-01

    In view of the current widespread concern about the risks associated with indoor radon exposures, this paper explores the evidence on risk from human epidemiology studies, particularly in reference to EPA's 4-pCi/L action level value and from animal studies. While the EPA 4-pCi/L level has no legal force and is not a standard per se, it is becoming a de facto standard as several states are considering the level in pending legislation. Although risk can also be related to radiation dose from radon exposure, this perspective on risk is not treated in this chapter

  13. Relevance of protection quantities in medical exposures

    International Nuclear Information System (INIS)

    Pradhan, A.S.

    2008-01-01

    International Commission on Radiological Protection (ICRP) continues to classify the exposures to radiation in three categories; namely 1- occupational exposure, 2- public exposure, and 3- medical exposure. Protection quantities are primarily meant for the regulatory purpose in radiological protection for controlling and limiting stochastic risks in occupational and public exposures. These are based on two basic assumptions of 1- linear no-threshold dose-effect relationship (LNT) at low doses and 2- long-term additivity of low doses. Medical exposure are predominantly delivered to individuals (patients) undergoing diagnostic examinations, interventional procedures and radiation therapy but also include individual caring for or comforting patients incurring exposure and the volunteers of biomedical medical research programmes. Radiation protection is as relevant to occupational and public exposure as to medical exposures except that the dose limits set for the formers are not applicable to medical exposure but reference levels and dose constrains are recommended for diagnostic and interventional medical procedures. In medical institutions, both the occupational and medical exposure takes place. Since the doses in diagnostic examinations are low, it has been observed that not only the protection quantities are often used in such cases but these are extended to estimate the number of cancer deaths due to such practices. One of the striking features of the new ICRP recommendations has been to elaborate the concepts of the dosimetric quantities. The limitation of protection quantities ((Effective dose, E=Σ RT D TR .W T .W R and Equivalent Dose H T =Σ RT D TR .W R ) have been brought out and this has raised a great concern and initiated debates on the use of these quantities in medical exposures. Consequently, ICRP has set a task group to provide more details and the recommendations. It has, therefore, became important to draw the attention of medical physics community

  14. Computer program for diagnostic X-ray exposure conversion

    International Nuclear Information System (INIS)

    Lewis, S.L.

    1984-01-01

    Presented is a computer program designed to convert any given set of diagnostic X-ray exposure factors sequentially into another, yielding either an equivalent photographic density or one increased or decreased by a specifiable proportion. In addition to containing the wherewithal with which to manipulate a set of exposure factors, the facility to print hard (paper) copy is included enabling the results to be pasted into a notebook and used at any time. This program was originally written as an investigative exercise into examining the potential use of computers for practical radiographic purposes as conventionally encountered. At the same time, its possible use as an educational tool was borne in mind. To these ends, the current version of this program may be used as a means whereby exposure factors used in a diagnostic department may be altered to suit a particular requirement or may be used in the school as a mathematical model to describe the behaviour of exposure factors under manipulation without patient exposure. (author)

  15. The Information System on Occupational Exposure in Medicine, Industry and Research (ISEMIR): Industrial Radiography

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-08-15

    Industrial radiography work is often carried out under difficult working conditions, such as in confined spaces, in extreme cold or heat, or during the night. Working under such adverse conditions might result in operational situations in which occupational radiation protection may be compromised. Experience shows that incidents involving industrial radiography sources have sometimes resulted in high doses to workers, causing severe health consequences such as radiation burns and, in a few cases, death. It has been long known that there is significant potential for industrial radiography personnel to receive non-trivial occupational exposure. However, a global perspective is lacking, as is the availability of a systematic means for improving occupational radiation protection in industrial radiography worldwide. In 2006, the IAEA published IAEA Safety Standards Series No. SF-1, Fundamental Safety Principles, jointly sponsored by the European Atomic Energy Community, the Food and Agriculture Organization of the United Nations (FAO), the International Labour Organization (ILO), the International Maritime Organization, the OECD Nuclear Energy Agency (OECD/NEA), the Pan American Health Organization (PAHO), the United Nations Environment Programme (UNEP) and the World Health Organization (WHO). That publication sets out the fundamental safety objective and principles of protection and safety. In 2014, the IAEA published IAEA Safety Standards Series No. GSR Part 3, Radiation Protection and Safety of Radiation Sources: International Basic Safety Standards (the BSS), jointly sponsored by the European Commission, the FAO, the ILO, OECD/NEA, the PAHO, UNEP and the WHO. The BSS sets out the requirements that are designed to meet fundamental safety objectives and to apply the principles specified in IAEA Safety Standards Series No. SF-1. The establishment of safety requirements and provision of guidance on occupational radiation protection is a major component of the support

  16. The Information System on Occupational Exposure in Medicine, Industry and Research (ISEMIR): Industrial Radiography

    International Nuclear Information System (INIS)

    2014-08-01

    Industrial radiography work is often carried out under difficult working conditions, such as in confined spaces, in extreme cold or heat, or during the night. Working under such adverse conditions might result in operational situations in which occupational radiation protection may be compromised. Experience shows that incidents involving industrial radiography sources have sometimes resulted in high doses to workers, causing severe health consequences such as radiation burns and, in a few cases, death. It has been long known that there is significant potential for industrial radiography personnel to receive non-trivial occupational exposure. However, a global perspective is lacking, as is the availability of a systematic means for improving occupational radiation protection in industrial radiography worldwide. In 2006, the IAEA published IAEA Safety Standards Series No. SF-1, Fundamental Safety Principles, jointly sponsored by the European Atomic Energy Community, the Food and Agriculture Organization of the United Nations (FAO), the International Labour Organization (ILO), the International Maritime Organization, the OECD Nuclear Energy Agency (OECD/NEA), the Pan American Health Organization (PAHO), the United Nations Environment Programme (UNEP) and the World Health Organization (WHO). That publication sets out the fundamental safety objective and principles of protection and safety. In 2014, the IAEA published IAEA Safety Standards Series No. GSR Part 3, Radiation Protection and Safety of Radiation Sources: International Basic Safety Standards (the BSS), jointly sponsored by the European Commission, the FAO, the ILO, OECD/NEA, the PAHO, UNEP and the WHO. The BSS sets out the requirements that are designed to meet fundamental safety objectives and to apply the principles specified in IAEA Safety Standards Series No. SF-1. The establishment of safety requirements and provision of guidance on occupational radiation protection is a major component of the support

  17. Exposure of bakery and pastry apprentices to airborne flour dust using PM2.5 and PM10 personal samplers

    Directory of Open Access Journals (Sweden)

    Paris Christophe

    2007-11-01

    Full Text Available Abstract Background This study describes exposure levels of bakery and pastry apprentices to flour dust, a known risk factor of occupational asthma. Methods Questionnaires on work activity were completed by 286 students. Among them, 34 performed a series of two personal exposure measurements using a PM2.5 and PM10 personal sampler during a complete work shift, one during a cold ("winter" period, and the other during a hot ("summer" period. Results Bakery apprentices experience greater average PM2.5 and PM10 exposures than pastry apprentices (p 10 values among bakers = 1.10 mg.m-3 [standard deviation: 0.83] than in summer (0.63 mg.m-3 [0.36]. While complying with current European occupational limit values, these exposures exceed the ACGIH recommendations set to prevent sensitization to flour dust (0.5 mg.m-3. Over half the facilities had no ventilation system. Conclusion Young bakery apprentices incur substantial exposure to known airways allergens, a situation that might elicit early induction of airways inflammation.

  18. Standard practice for conducting moist SO2 tests

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This practice covers the apparatus and procedure to be used in conducting qualitative assessment tests in accordance with the requirements of material or product specifications by means of specimen exposure to condensed moisture containing sulfur dioxide. 1.2 The exposure conditions may be varied to suit particular requirements and this practice includes provisions for use of different concentrations of sulfur dioxide and for tests either running continuously or in cycles of alternate exposure to the sulfur dioxide containing atmosphere and to the ambient atmosphere. 1.3 The variant of the test to be used, the exposure period required, the type of test specimen, and the criteria of failure are not prescribed by this practice. Such details are provided in appropriate material and product purchase specifications. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety c...

  19. Return to Flying Duties Following Centrifuge or Vibration Exposures

    Science.gov (United States)

    Scheuring, Richard A.; Clarke, Jonathan; Jones, Jeffrey A.

    2009-01-01

    Introduction: In an effort to determine the human performance limits for vibration in spacecraft being developed by NASA, astronauts were evaluated during a simulated launch profile in a centrifuge/vibration environment and separate vibration-only simulation. Current USAF and Army standards for return to flight following centrifuge exposures require 12-24 hours to pass before a crewmember may return to flying duties. There are no standards on vibration exposures and return to flying duties. Based on direct observation and provocative neurological testing of the astronauts, a new standard for return to flying duties following centrifuge and/or vibration exposures was established. Methods: 13 astronaut participants were exposed to simulated launch profiles in a + 3.5 Gx bias centrifuge/vibration environment and separately on a vibration table at the NASA-Ames Research Center. Each subject had complete neurological evaluations pre- and post-exposure for the centrifuge/vibration runs with the NASA neurological function rating scale (NFRS). Subjects who participated in the vibration-only exposures had video oculography performed with provocative maneuvers in addition to the NFRS. NFRS evaluations occurred immediately following each exposure and at 1 hour post-run. Astronauts who remained symptomatic at 1 hour had repeat NFRS performed at 1 hour intervals until the crewmember was asymptomatic. Results: Astronauts in the centrifuge/vibration study averaged a 3-5 point increase in NFRS scores immediately following exposure but returned to baseline 3 hours post-run. Subjects exposed to the vibration-only simulation had a 1-3 point increase following exposure and returned to baseline within 1-2 hours. Pre- and post- vibration exposure video oculography did not reveal any persistent ocular findings with provocative testing 1 hour post-exposure. Discussion: Based on direct observations and objective measurement of neurological function in astronauts following simulated launch

  20. Setting the standard: Medical Education's first 50 years.

    Science.gov (United States)

    Rangel, Jaime C; Cartmill, Carrie; Kuper, Ayelet; Martimianakis, Maria A; Whitehead, Cynthia R

    2016-01-01

    By understanding its history, the medical education community gains insight into why it thinks and acts as it does. This piece provides a Foucauldian archaeological critical discourse analysis (CDA) of the journal Medical Education on the publication of its 50th Volume. This analysis draws upon critical social science perspectives to allow the examination of unstated assumptions that underpin and shape educational tools and practices. A Foucauldian form of CDA was utilised to examine the journal over its first half-century. This approach emphasises the importance of language, and the ways in which words used affect and are affected by educational practices and priorities. An iterative methodology was used to organise the very large dataset (12,000 articles). A distilled dataset, within which particular focus was placed on the editorial pieces in the journal, was analysed. A major finding was the diversity of the journal as a site that has permitted multiple - and sometimes contradictory - discursive trends to emerge. One particularly dominant discursive tension across the time span of the journal is that between a persistent drive for standardisation and a continued questioning of the desirability of standardisation. This tension was traced across three prominent areas of focus in the journal: objectivity and the nature of medical education knowledge; universality and local contexts, and the place of medical education between academia and the community. The journal has provided the medical education community with a place in which to both discuss practical pedagogical concerns and ponder conceptual and social issues affecting the medical education community. This dual nature of the journal brings together educators and researchers; it also gives particular focus to a major and rarely cited tension in medical education between the quest for objective standards and the limitations of standard measures. © 2015 John Wiley & Sons Ltd.

  1. What's in a ray set: moving towards a unified ray set format

    Science.gov (United States)

    Muschaweck, Julius

    2011-10-01

    For the purpose of optical simulation, a plethora of formats exist to describe the properties of a light source. Except for the EULUMDAT and IES formats which describe sources in terms of aperture area and far field intensity, all these formats are vendor specific, and no generally accepted standard exists. Most illumination simulation software vendors use their own format for ray sets, which describe sources in terms of many rays. Some of them keep their format definition proprietary. Thus, software packages typically can read or write only their own specific format, although the actual data content is not so different. Typically, they describe origin and direction of each ray in 3D vectors, and use one more single number for magnitude, where magnitude may denote radiant flux, luminous flux (equivalently tristimulus Y), or tristimulus X and Z. Sometimes each ray also carries its wavelength, while other formats allow to specify an overall spectrum for the whole source. In addition, in at least one format, polarization properties are also included for each ray. This situation makes it inefficient and potentially error prone for light source manufacturers to provide ray data sets for their sources in many different formats. Furthermore, near field goniometer vendors again use their proprietary formats to store the source description in terms of luminance data, and offer their proprietary software to generate ray sets from this data base. Again, the plethora of ray sets make the ray set production inefficient and potentially error prone. In this paper, we propose to describe ray data sets in terms of phase space, as a step towards a standardized ray set format. It is well known that luminance and radiance can be defined as flux density in phase space: luminance is flux divided by etendue. Therefore, single rays can be thought of as center points of phase space cells, where each cell possesses its volume (i.e. etendue), its flux, and therefore its luminance. In

  2. Seven-year neurodevelopmental scores and prenatal exposure to chlorpyrifos, a common agricultural pesticide.

    Science.gov (United States)

    Rauh, Virginia; Arunajadai, Srikesh; Horton, Megan; Perera, Frederica; Hoepner, Lori; Barr, Dana B; Whyatt, Robin

    2011-08-01

    In a longitudinal birth cohort study of inner-city mothers and children (Columbia Center for Children's Environmental Health), we have previously reported that prenatal exposure to chlorpyrifos (CPF) was associated with neurodevelopmental problems at 3 years of age. The goal of the study was to estimate the relationship between prenatal CPF exposure and neurodevelopment among cohort children at 7 years of age. In a sample of 265 children, participants in a prospective study of air pollution, we measured prenatal CPF exposure using umbilical cord blood plasma (picograms/gram plasma) and 7-year neurodevelopment using the Wechsler Intelligence Scale for Children, 4th edition (WISC-IV). Linear regression models were used to estimate associations, with covariate selection based on two alternate approaches. On average, for each standard deviation increase in CPF exposure (4.61 pg/g), Full-Scale intelligence quotient (IQ) declined by 1.4% and Working Memory declined by 2.8%. Final covariates included maternal educational level, maternal IQ, and quality of the home environment. We found no significant interactions between CPF and any covariates, including the other chemical exposures measured during the prenatal period (environmental tobacco smoke and polycyclic aromatic hydrocarbons). We report evidence of deficits in Working Memory Index and Full-Scale IQ as a function of prenatal CPF exposure at 7 years of age. These findings are important in light of continued widespread use of CPF in agricultural settings and possible longer-term educational implications of early cognitive deficits.

  3. Development of acute exposure guideline levels for airborne exposures to hazardous substances.

    Science.gov (United States)

    Krewski, Daniel; Bakshi, Kulbir; Garrett, Roger; Falke, Ernest; Rusch, George; Gaylor, David

    2004-04-01

    Hazardous substances can be released into the atmosphere due to industrial and transportation accidents, fires, tornadoes, earthquakes, and terrorists, thereby exposing workers and the nearby public to potential adverse health effects. Various enforceable guidelines have been set by regulatory agencies for worker and ambient air quality. However, these exposure levels generally are not applicable to rare lifetime acute exposures, which possibly could occur at high concentrations. Acute exposure guideline levels (AEGLs) provide estimates of concentrations for airborne exposures for an array of short durations that possibly could cause mild (AEGL-1), severe, irreversible, potentially disabling adverse health effects (AEGL-2), or life threatening effects (AEGL-3). These levels can be useful for emergency responders and planners in reducing or eliminating potential risks to the public. Procedures and methodologies for deriving AEGLs are reviewed in this paper that have been developed in the United States, with direct input from international representatives of OECD member-countries, by the National Advisory Committee for Acute Exposure Guidelines for Hazardous Substances and reviewed by the National Research Council. Techniques are discussed for the extrapolation of effects across different exposure durations. AEGLs provide a viable approach for assisting in the prevention, planning, and response to acute airborne exposures to toxic agents.

  4. Mental health problems due to community violence exposure in a small urban setting

    Directory of Open Access Journals (Sweden)

    Faraz Ahmad

    2017-10-01

    Full Text Available Objective: Studies conducted in large metropolitan inner-city communities with high violent crime rates have demonstrated an association between exposure to violence and mental health problems; therefore the purpose of this study was to determine if similar trends exist in smaller inner-city communities with substantially lower violent crime rates. Methods: One hundred twenty-six children and young adults living in inner-city Omaha, Nebraska, were screened for posttraumatic stress disorder (PTSD, depression, and anxiety symptoms and assessed for community violence exposure (CVE. Pearson’s correlation and analysis of variance were used to determine the relationship between PTSD, depression, and anxiety symptoms and CVE. Results: A statistically significant relationship was found between CVE and PTSD and anxiety symptoms among participants despite their having lower rates of exposure to violent events in comparison with other studies. No association was found between violence and depression symptoms. Additionally, the presence of anxiety and depression, as well as increased age of participants, was associated with higher rates of PTSD symptoms. Conclusion: We recommend that health care providers in smaller cities, where the effects of violent crime may be underestimated or overlooked, be informed of the existence of this public health problem within their community and that they screen at-risk patients for mental health problems.

  5. Calculations of standard-Higgs-boson production cross sections in e+e- collisions by means of a reasonable set of parameters

    International Nuclear Information System (INIS)

    Biyajima, M.; Shirane, K.; Terazawa, O.

    1987-01-01

    We calculate cross sections for production of the standard Higgs boson in e + e - collisions and compare our results with those of several authors. It is found that there are appreciable differences among them which can be attributed to the coupling constants used, α(0) ( = (1/137) and G/sub F/. We also observe that cross sections depend on the magnitudes of the total width of the Z particle. The use of a reasonable set of parameters in calculations is emphasized

  6. Association Between Prenatal Valproate Exposure and Performance on Standardized Language and Mathematics Tests in School-aged Children

    DEFF Research Database (Denmark)

    Elkjær, Lars Skou; Bech, Bodil Hammer; Sun, Yuelian

    2018-01-01

    by Statistics Denmark on April 15, 2016. All children born alive in Denmark between 1997 and 2006 (n = 656 496) were identified. From this cohort, children who did not participate in the national tests, with presumed coding errors in gestational age and children missing information on their mother's educational......Importance: Valproate sodium is used for the treatment of epilepsy and other neuropsychiatric disorders in women of childbearing potential. However, there are concerns about impaired cognitive development in children who have been exposed to valproate during pregnancy. Objective: To estimate...... the association between long-term school performance and prenatal exposure to valproate and a number of other antiepileptic drugs (AEDs). Design, Setting, and Participants: In a prospective, population-based cohort study conducted from August 1, 2015, to May 31, 2017, data used in the study were provided...

  7. Optimized control of X-ray exposure and image noise using a particular multislice CT scanner

    International Nuclear Information System (INIS)

    Yamamoto, Shuji; Suzuki, Masahiro; Kakinuma, Ryutaro; Moriyama, Noriyuki; Koyama, Yoshihiro; Nagasawa, Hirofumi

    2008-01-01

    Patient dose reduction in computed tomography (CT) always results in a trade off between radiation exposure and image quality. There are few reports that estimate the relationship between image quality and X-ray exposure in CT examinations as one optimal index. The purpose of this study was to determine the optimal parameter settings enabling a low radiation exposure without compromising image quality using a particular 4-row multislice CT (MSCT) scanner (Aquilion VZ 4-slice CT scanner, Toshiba Medical Systems Corporation, Otawara, Tochigi, Japan). Normalized dose divided by image noise for helical pitches (nDNR: normalized dose to noise ratio) were calculated in consideration of beam collimation and tube current-time product. Optimal tube current-time product was calculated using the nDNR for the helical pitches based on user-defined standards of quality of the CT image. As a result, the nDNR proved to be well-supported to decrease the patient exposure in various exposure conditions of MSCT scans; however, the dose and image noise did not show a linear relation to the helical pitch. In conclusion, nDNR can be applied to patient dose reduction while keeping an acceptable image quality using a particular 4-row MSCT scanner. (author)

  8. Dermal exposure assessment to benzene and toluene using charcoal cloth pads

    NARCIS (Netherlands)

    Wendel de Joode, B. van; Tielemans, E.; Vermeulen, R.; Wegh, H.; Kromhout, H.

    2005-01-01

    Charcoal cloth pads have been used to assess volatile chemicals on the skin in a laboratory setting; however, they have not yet been applied to measure dermal exposure in occupational settings. This study aimed at evaluating whether charcoal pads can be used to assess dermal exposure to benzene and

  9. On the radiation exposure in temporomandibular joint examinations

    International Nuclear Information System (INIS)

    Rother, U.; Hildebrandt, K.H.

    1979-01-01

    The radiation exposure caused by standardized examinations of the temporomandibular joint has been determined with the aid of 660 exposures of an Alderson phantom. Comparative examinations were performed with the classic contact technique according to Parma to elucidate the results obtained. The lowest surface exposure was observed in contact examinations of the temporomandibular joint. Application of a flat cone led to a 13-fold reduction in surface exposure compared to contact examinations according to Parma. Furthermore, radiation exposure strongly decreased from the irradiation field to the adjacent area if a cone (flat cone and ear cone) was used. (author)

  10. Aiming for a holistic integrated service for men diagnosed with prostate cancer - Definitions of standards and skill sets for nurses and allied healthcare professionals.

    Science.gov (United States)

    Lamb, Alastair D; Thompson, Sue; Kinsella, Netty; Gerbitz, Ingmar; Chapman, Elaine; Putt, Lisa; Bennett, Sophie; Thankappannair, Vineetha; Geoghegan, Lisa; Wright, Naomi; Stirton-Croft, Alison; Nixon, Penny; Styling, Andrew; Whitney, Diane; Hodgson, Lindsay; Punt, Lisa; Longmore, Jenny; Carter, Mike; Petch, Bill; Rimmer, Yvonne; Russell, Simon; Hughes-Davies, Luke; Mazhar, Danish; Shah, Nimish C; Gnanapragasam, Vincent J; Doble, Andrew; Bratt, Ola; Kastner, Christof

    2017-08-01

    To establish a comprehensive set of recommendations for the service structure and skill set of nurses and allied healthcare professionals in prostate cancer care. Using components of formal consensus methodology, a 30-member multidisciplinary panel produced 53 items for discussion relating to the provision of care for prostate cancer patients by specialist nurses and allied healthcare professionals. Items were developed by two rounds of email correspondence in which, first, items were generated and, second, items refined to form the basis of a consensus meeting which constituted the third round of review. The fourth and final round was an email review of the consensus output. The panel agreed on 33 items that were appropriate for recommendations to be made. These items were grouped under categories of "Environment" and "Patient Pathway" and included comments on training, leadership, communication and quality assessment as well as specific items related to prostate diagnosis clinics, radical treatment clinics and follow-up survivor groups. Specialist nurses and allied healthcare professionals play a vital role alongside urologists and oncologists to provide care to men with prostate cancer and their families. We present a set of standards and consensus recommendations for the roles and skill-set required for these practitioners to provide gold-standard prostate cancer care. These recommendations could form the basis for development of comprehensive integrated prostate cancer pathways in prostate cancer centres as well as providing guidance for any units treating men with prostate cancer. Copyright © 2017. Published by Elsevier Ltd.

  11. International policy and advisory response regarding children's exposure to radio frequency electromagnetic fields (RF-EMF).

    Science.gov (United States)

    Redmayne, Mary

    2016-01-01

    Radiofrequency electromagnetic field (RF-EMF) exposure regulations/guidelines generally only consider acute effects, and not chronic, low exposures. Concerns for children's exposure are warranted due to the amazingly rapid uptake of many wireless devices by increasingly younger children. This review of policy and advice regarding children's RF-EMF exposure draws material from a wide variety of sources focusing on the current situation. This is not a systematic review, but aims to provide a representative cross-section of policy and advisory responses within set boundaries. There are a wide variety of approaches which I have categorized and tabulated ranging from ICNIRP/IEEE guidelines and "no extra precautions needed" to precautionary or scientific much lower maxima and extensive advice to minimize RF-EMF exposure, ban advertising/sale to children, and add exposure information to packaging. Precautionary standards use what I term an exclusion principle. The wide range of policy approaches can be confusing for parents/carers of children. Some consensus among advisory organizations would be helpful acknowledging that, despite extensive research, the highly complex nature of both RF-EMF and the human body, and frequent technological updates, means simple assurance of long-term safety cannot be guaranteed. Therefore, minimum exposure of children to RF-EMF is recommended. This does not indicate need for alarm, but mirrors routine health-and-safety precautions. Simple steps are suggested. ICNIRP guidelines need to urgently publish how the head, torso, and limbs' exposure limits were calculated and what safety margin was applied since this exposure, especially to the abdomen, is now dominant in many children.

  12. 49 CFR 229.73 - Wheel sets.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Wheel sets. 229.73 Section 229.73 Transportation... TRANSPORTATION RAILROAD LOCOMOTIVE SAFETY STANDARDS Safety Requirements Suspension System § 229.73 Wheel sets. (a...) when applied or turned. (b) The maximum variation in the diameter between any two wheel sets in a three...

  13. Occupational Blood Exposure among Health Care Personnel and Hospital Trainees

    Directory of Open Access Journals (Sweden)

    M Hajjaji Darouiche

    2014-01-01

    Full Text Available Blood and body fluid Exposure is a major occupational safety problems for health care workers. Therefore, we conducted a descriptive and retrospective study to identify the characteristics of blood exposure accidents in health care settings which lasted five years (2005-2009 at the two university hospitals of Sfax. We have 593 blood exposure accidents in health care settings 152 (25.6% health personnel and 441 (74.4% trainees' doctors, nurses and health technicians. The mechanism of blood and body fluid exposure was accidental needle-stick injury in 78.9% of health staff, and 81% of trainees, accidental cut in 14.7% of health workers and 10.2% of trainees. The increasing severity of blood exposure accidents is linked to the lack of safe behavior against this risk.

  14. Electrostatic Discharge Test of Multi-Junction Solar Array Coupons After Combined Space Environmental Exposures

    Science.gov (United States)

    Wright, Kenneth H.; Schneider, Todd; Vaughn, Jason; Hoang, Bao; Funderburk, Victor V.; Wong, Frankie; Gardiner, George

    2010-01-01

    A set of multi-junction GaAs/Ge solar array test coupons were subjected to a sequence of 5-year increments of combined environmental exposure tests. The test coupons capture an integrated design intended for use in a geosynchronous (GEO) space environment. A key component of this test campaign is conducting electrostatic discharge (ESD) tests in the inverted gradient mode. The protocol of the ESD tests is based on the ISO/CD 11221, the ISO standard for ESD testing on solar array panels. This standard is currently in its final review with expected approval in 2010. The test schematic in the ISO reference has been modified with Space System/Loral designed circuitry to better simulate the on-orbit operational conditions of its solar array design. Part of the modified circuitry is to simulate a solar array panel coverglass flashover discharge. All solar array coupons used in the test campaign consist of 4 cells. The ESD tests are performed at the beginning of life (BOL) and at each 5-year environment exposure point. The environmental exposure sequence consists of UV radiation, electron/proton particle radiation, thermal cycling, and ion thruster plume. This paper discusses the coverglass flashover simulation, ESD test setup, and the importance of the electrical test design in simulating the on-orbit operational conditions. Results from 5th-year testing are compared to the baseline ESD characteristics determined at the BOL condition.

  15. Tanning lamps ultraviolet emissions and compliance with technical standards

    International Nuclear Information System (INIS)

    Bonino, A.; Facta, S.; Saudino, S.; Anglesio, L.; D'Amore, G.

    2009-01-01

    In this work the compliance of tanning lamps with technical standards EN 60335-2-27 'Household and similar electrical appliances-Safety. Part 2: Particular requirements for appliances for skin exposure to ultraviolet and infrared radiation' was analysed. Results of this analysis showed that none of the examined technical documentation produced by the lamps manufacturers is fully compliant with the standard technique. Furthermore data reported in the same manuals, such as effective radiant exposure or irradiance, would indicate that these sources may be the cause of undue exposure to ultraviolet (UV) radiation. For this reason a measurement campaign on UV lamps used in tanning salons was organised. The first results of these measurements seem to confirm the doubts raised from the analysis of the lamp manuals: the use of a tanning lamp can lead to UV radiation exposure levels higher than reference maximum values recommended by EN 60335-2-27. (authors)

  16. Clustering of Sun Exposure Measurements

    OpenAIRE

    Have, Anna Szynkowiak; Larsen, Jan; Hansen, Lars Kai; Philipsen, Peter Alshede; Thieden, Elisabeth; Wulf, Hans Christian

    2002-01-01

    In a medically motivated Sun-exposure study, questionnaires concerning Sun-habits were collected from a number of subjects together with UV radiation measurements. This paper focuses on identifying clusters in the heterogeneous set of data for the purpose of understanding possible relations between Sun-habits exposure and eventually assessing the risk of skin cancer. A general probabilistic framework originally developed for text and Web mining is demonstrated to be useful for clustering of b...

  17. Physical setting and natural sources of exposure to carcinogenic trace elements and radionuclides in Lahontan Valley, Nevada

    Science.gov (United States)

    Seiler, Ralph L.

    2012-01-01

    In Lahontan Valley, Nevada, arsenic, cobalt, tungsten, uranium, radon, and polonium-210 are carcinogens that occur naturally in sediments and groundwater. Arsenic and cobalt are principally derived from erosion of volcanic rocks in the local mountains and tungsten and uranium are derived from erosion of granitic rocks in headwater reaches of the Carson River. Radon and 210Po originate from radioactive decay of uranium in the sediments. Arsenic, aluminum, cobalt, iron, and manganese concentrations in household dust suggest it is derived from the local soils. Excess zinc and chromium in the dust are probably derived from the vacuum cleaner used to collect the dust, or household sources such as the furnace. Some samples have more than 5 times more cobalt in the dust than in the local soil, but whether the source of the excess cobalt is anthropogenic or natural cannot be determined with the available data. Cobalt concentrations are low in groundwater, but arsenic, uranium, radon, and 210Po concentrations often exceed human-health standards, and sometime greatly exceed them. Exposure to radon and its decay products in drinking water can vary significantly depending on when during the day that the water is consumed. Although the data suggests there have been no long term changes in groundwater chemistry that corresponds to the Lahontan Valley leukemia cluster, the occurrence of the very unusual leukemia cluster in an area with numerous 210Po and arsenic contaminated wells is striking, particularly in conjunction with the exceptionally high levels of urinary tungsten in Lahontan Valley residents. Additional research is needed on potential exposure pathways involving food or inhalation, and on synergistic effects of mixtures of these natural contaminants on susceptibility to development of leukemia.

  18. Physical setting and natural sources of exposure to carcinogenic trace elements and radionuclides in Lahontan Valley, Nevada.

    Science.gov (United States)

    Seiler, Ralph

    2012-04-05

    In Lahontan Valley, Nevada, arsenic, cobalt, tungsten, uranium, radon, and polonium-210 are carcinogens that occur naturally in sediments and groundwater. Arsenic and cobalt are principally derived from erosion of volcanic rocks in the local mountains and tungsten and uranium are derived from erosion of granitic rocks in headwater reaches of the Carson River. Radon and 210Po originate from radioactive decay of uranium in the sediments. Arsenic, aluminum, cobalt, iron, and manganese concentrations in household dust suggest it is derived from the local soils. Excess zinc and chromium in the dust are probably derived from the vacuum cleaner used to collect the dust, or household sources such as the furnace. Some samples have more than 5 times more cobalt in the dust than in the local soil, but whether the source of the excess cobalt is anthropogenic or natural cannot be determined with the available data. Cobalt concentrations are low in groundwater, but arsenic, uranium, radon, and 210Po concentrations often exceed human-health standards, and sometime greatly exceed them. Exposure to radon and its decay products in drinking water can vary significantly depending on when during the day that the water is consumed. Although the data suggests there have been no long term changes in groundwater chemistry that corresponds to the Lahontan Valley leukemia cluster, the occurrence of the very unusual leukemia cluster in an area with numerous 210Po and arsenic contaminated wells is striking, particularly in conjunction with the exceptionally high levels of urinary tungsten in Lahontan Valley residents. Additional research is needed on potential exposure pathways involving food or inhalation, and on synergistic effects of mixtures of these natural contaminants on susceptibility to development of leukemia. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  19. The International Accounting Standards Board’s Progress in Promoting Judgement Through Objectives-Oriented Accounting Standards

    OpenAIRE

    Tanja Lakovic; Jayne Fuglister

    2013-01-01

    This study analyzes how the International Accounting Standards Board (IASB) promotes professional judgement by issuing objectives-oriented accounting standards and exposure drafts.  We focus on the the role of judgement as outlined in Phase I of the IASB Conceptual Framework (CF), Chapter 1, “Objective of General Purpose Financial Statements” and Chapter 3, “Qualitative Characteristics of Useful Financial Information” (IASB 2010). We discuss how the framework, when viewed through the prism of...

  20. Does habituation really happen? Investigation of psycho-biological responses to body exposure in bulimia nervosa.

    Science.gov (United States)

    Trentowska, Monika; Svaldi, Jennifer; Blechert, Jens; Tuschen-Caffier, Brunna

    2017-03-01

    Body exposure is a common and effective treatment for body image disturbance in bulimia nervosa (BN). However, little is known about treatment mechanisms. Based on models of emotional processing and neurovisceral integration, we expected to observe a) initial activation and b) habituation of cognitive-affective and autonomic responding within one and between two standardized body exposure sessions. A group of 13 women with BN and 13 healthy controls (HC) were repeatedly exposed to their bodies. Prior to and after treatment with three individualized mirror exposure sessions participants received a session of standardized exposure to videographic recordings of their body. Subjective ratings of body-related emotions and thoughts were assessed repeatedly throughout the standardized exposure sessions and autonomic responses were recorded continuously. Subjective and sympathetic responses were activated initially in both groups. Cognitive-affective responses habituated within the standardized sessions in both groups, whereas between the standardized sessions habituation was only found in women with BN. Increasing sympathetic responses were found within the sessions in both groups. The results support cognitive-affective habituation during body exposure in BN and to a lesser extent in HC. Autonomic responses however did not show a corresponding pattern and did not distinguish between groups. Implications for body exposure research and practice are discussed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Development of prognostic occupational air standards for nanoparticles

    International Nuclear Information System (INIS)

    Radilov, Andrey S; Glushkova, Anzhela V; Dulov, Sergej A; Khlebnikova, Nataliya S

    2011-01-01

    The intensive progress of nanoindustry in the Russian Federation makes quite urgent the problem of development and especially express development of occupational exposure standards for nanoparticles and nanoaerosols in the workplace air. We developed an approach to comparative toxicity assessment and express calculation of occupational exposure standards for nanoaerosols, based on criteria for the development of maximum allowable concentrations (MACs) of aerosols in the workplace air. The developed approach was used to obtain prognostic MACs of certain aerosols in the workplace air, mg/m 3 : nano-Ag 0.08, nano-TiO 2 0.19, and C 60 0.08.

  2. Exposure assessment strategies for non-routine work operations (NORWO)

    International Nuclear Information System (INIS)

    Lew, V.; Cohen, J.; Chiusano, S.; McGann, C.; McLouth, L.

    1993-09-01

    The DOE Office of Health and Office of Safety and Health Oversight are collaborating to address special problems related to assessment of worker exposures associated with nonroutine work operations (NORWO), such as hazardous waste operations. Both off ices have formed a single working group of industrial hygiene specialists from the DOE, fts contractors, and other interested organizations which held its first meeting July 1993. The DOE Canter of Excellence for Exposure Assessment, maintained at Lawrence Livermore National Laboratory, is assisting in developing reasonable policies and guidance on exposure assessment strategies for NORWO. The DOE EA Center will research this subject to assist the DOE in formulating guidance documents for conduct of EA for NORWO that are consistent with the DOE draft EAS technical standard. This report presents an outline for a section on NORWO intended for inclusion in the DOE technical guidance documents for EAS and Hazardous Waste Operations Emergency Response (HAZWOPER) currently under development by the DOE Industrial Hygiene Division (EH-412), and EM-23. Also presented is a review of the July 21--23 meeting and a proposed workplan for developing NORWO exposure assessment procedures. Appendices include: (A) David Weitzman's memo on NORWO, (B) Draft annotated outline of the technical standard for the Assessment of Employee Exposure to Hazardous Chemical Agents, (C) ORC proposed EAS standard, (D) program for the October 31--November 3, 1993 ACGIH Conference on Occupational Exposure Databases, (E) agenda for the July 15, 1993 DOE meeting on NORWO, (F) viewgraphs used in formal presentations at this meeting, (G) Hanford Exposure Assessment Program Plan, and (H) a list of attendees and invitees to the July DOE -- NORWO meeting

  3. Noise Producing Toys and the Efficacy of Product Standard Criteria to Protect Health and Education Outcomes

    Directory of Open Access Journals (Sweden)

    Stuart J. McLaren

    2013-12-01

    Full Text Available An evaluation of 28 commercially available toys imported into New Zealand revealed that 21% of these toys do not meet the acoustic criteria in the ISO standard, ISO 8124-1:2009 Safety of Toys, adopted by Australia and New Zealand as AS/NZS ISO 8124.1:2010. While overall the 2010 standard provided a greater level of protection than the earlier 2002 standard, there was one high risk toy category where the 2002 standard provided greater protection. A secondary set of toys from the personal collections of children known to display atypical methods of play with toys, such as those with autism spectrum disorders (ASD, was part of the evaluation. Only one of these toys cleanly passed the 2010 standard, with the remainder failing or showing a marginal-pass. As there is no tolerance level stated in the standards to account for interpretation of data and experimental error, a value of +2 dB was used. The findings of the study indicate that the current standard is inadequate in providing protection against excessive noise exposure. Amendments to the criteria have been recommended that apply to the recently adopted 2013 standard. These include the integration of the new approaches published in the recently amended European standard (EN 71 on safety of toys.

  4. Noise producing toys and the efficacy of product standard criteria to protect health and education outcomes.

    Science.gov (United States)

    McLaren, Stuart J; Page, Wyatt H; Parker, Lou; Rushton, Martin

    2013-12-19

    An evaluation of 28 commercially available toys imported into New Zealand revealed that 21% of these toys do not meet the acoustic criteria in the ISO standard, ISO 8124-1:2009 Safety of Toys, adopted by Australia and New Zealand as AS/NZS ISO 8124.1:2010. While overall the 2010 standard provided a greater level of protection than the earlier 2002 standard, there was one high risk toy category where the 2002 standard provided greater protection. A secondary set of toys from the personal collections of children known to display atypical methods of play with toys, such as those with autism spectrum disorders (ASD), was part of the evaluation. Only one of these toys cleanly passed the 2010 standard, with the remainder failing or showing a marginal-pass. As there is no tolerance level stated in the standards to account for interpretation of data and experimental error, a value of +2 dB was used. The findings of the study indicate that the current standard is inadequate in providing protection against excessive noise exposure. Amendments to the criteria have been recommended that apply to the recently adopted 2013 standard. These include the integration of the new approaches published in the recently amended European standard (EN 71) on safety of toys.

  5. Advanced REACH tool: A Bayesian model for occupational exposure assessment

    NARCIS (Netherlands)

    McNally, K.; Warren, N.; Fransman, W.; Entink, R.K.; Schinkel, J.; Van Tongeren, M.; Cherrie, J.W.; Kromhout, H.; Schneider, T.; Tielemans, E.

    2014-01-01

    This paper describes a Bayesian model for the assessment of inhalation exposures in an occupational setting; the methodology underpins a freely available web-based application for exposure assessment, the Advanced REACH Tool (ART). The ART is a higher tier exposure tool that combines disparate

  6. Assessment of Human Exposure to ENMs.

    Science.gov (United States)

    Jiménez, Araceli Sánchez; van Tongeren, Martie

    2017-01-01

    Human exposure assessment of engineered nanomaterials (ENMs) is hampered, among other factors, by the difficulty to differentiate ENM from other nanomaterials (incidental to processes or naturally occurring) and the lack of a single metric that can be used for health risk assessment. It is important that the exposure assessment is carried out throughout the entire life-cycle as releases can occur at the different stages of the product life-cycle, from the synthesis, manufacture of the nano-enable product (occupational exposure) to the professional and consumer use of nano-enabled product (consumer exposure) and at the end of life.Occupational exposure surveys should follow a tiered approach, increasing in complexity in terms of instruments used and sampling strategy applied with higher tiers in order tailor the exposure assessment to the specific materials used and workplace exposure scenarios and to reduce uncertainty in assessment of exposure. Assessment of consumer exposure and of releases from end-of-life processes currently relies on release testing of nano-enabled products in laboratory settings.

  7. Preliminary Assessment of Radiofrequency Radiation Exposure Level, From Mobile Base Stations in Ajaokuta and Environs, Kogi State, Nigeria

    International Nuclear Information System (INIS)

    Ushie, P. O.; Nwankwo, U.J.V.; Osahun, O. D.; Ayinmode, B.

    2013-01-01

    We present the result of a preliminary assessment of radio-frequency radiation exposure from selected mobile base stations in Ajaokuta environs using radio frequency (RF) meter (electromoge meter). The Power density of RF radiation within a radial distance of 125m was measured. Although values fluctuated due to the influence of unavoidable factors suspected to be interferences from other electromagnetic sources around reference base stations, we show from analysis that radiation exposure level is far below the standard limit (10W/cm 2 or 10 7 μW/m 2 ) set by the International Commission on Non-ionizing Radiation Protection (ICNIRP) regulatory agencies. The assessment was done in about ten (10) base stations in Ajaokuta, Kogi state. The position and elevation of the base stations were noted using a global positioning system (GPS) to ascertain the position of such stations on the world map. It was discovered that the limit of exposure to radio frequency radiation set by International Commission on Non-ionizing, Radiation Protection (ICNIRP) of 900MHz band expressed in the same unit as 10W/cm 2 or 10 7 μW/m 2 was not exceeded, the values were also influenced by some inevitable factors. Positions of most of the stations are sited close to homes.

  8. Status of air kerma and absorbed dose standards in India

    International Nuclear Information System (INIS)

    Vijayam, M.; Ramanathan, G.; Patki, V.S.; Soman, A.T.; Shigwan, J.B.; Vinatha, S.P.; Jadhavgaonkar, P.S.; Kadam, V.D.; Shaha, V.V.; Abani, M.C.

    2002-01-01

    Full text: The Radiation Safety Systems Division of Bhabha Atomic Research Centre, India maintains Primary and Secondary Standards of various parameters of radiation measurements and provides calibration services to various users of radiation in the country. This is an apex laboratory in India and plays a pivotal role in ensuring accurate radiological measurements. The laboratory coordinates national intercomparisons of radiation measurements to maintain their uniformity and traceability and is linked through various programmes with the other International organizations such as Bureau Internationale des Poids et Mesures (BIPM) Paris, International Atomic Energy Agency (IAEA) Vienna, Asia Pacific Metrology Programme (APMP) Taiwan. It is the recognized Regional Secondary Standards Dosimetry Laboratory (SSDL) of IAEA/WHO (World Health Organisation). This paper brings out the status of various primary and secondary standards for radiological measurements maintained at BARC. 1. Primary Exposure/Air-kerma standard at Co-60 energy (therapy level): The primary standard for exposure/ air-kerma measurements maintained at BARC is a graphite cavity chamber of volume 4.362 cc with an internal diameter of 1.8 cm, internal height of 1.78 cm and wall thickness of 704.3mg/cm 2 . Correction factors for the difference between electron stopping powers, photon mass energy absorption coefficients of air and graphite wall, correction for recombination, radiation field non-uniformity, stem scatter and polarity effect are applied and the maximum overall uncertainty in the realisation of exposure/air-kerma is around ±1%. This standard has been intercompared with IAEA and BIPM through transfer standard and the agreement in the results are better than ±1%. An intercomparison under the APMP programme is to be held during May, 2002. 2. Primary Exposure/Air-kerma standard at protection and brachytherapy level: A set of three spherical graphite-walled cavity chambers of different air

  9. Trends of VOC exposures among a nationally representative sample: Analysis of the NHANES 1988 through 2004 data sets

    Science.gov (United States)

    Su, Feng-Chiao; Mukherjee, Bhramar; Batterman, Stuart

    2011-09-01

    Exposures to volatile organic compounds (VOCs) are ubiquitous due to emissions from personal, commercial and industrial products, but quantitative and representative information regarding long term exposure trends is lacking. This study characterizes trends from 1988 to 2004 for the 15 VOCs measured in blood in five cohorts of the National Health and Nutrition Examination Survey (NHANES), a large and representative sample of U.S. adults. Trends were evaluated at various percentiles using linear quantile regression (QR) models, which were adjusted for solvent-related occupations and cotinine levels. Most VOCs showed decreasing trends at all quantiles, e.g., median exposures declined by 2.5 (m,p-xylene) to 6.4 (tetrachloroethene) percent per year over the 15 year period. Trends varied by VOC and quantile, and were grouped into three patterns: similar decreases at all quantiles (including benzene, toluene); most rapid decreases at upper quantiles (ethylbenzene, m,p-xylene, o-xylene, styrene, chloroform, tetrachloroethene); and fastest declines at central quantiles (1,4-dichlorobenzene). These patterns reflect changes in exposure sources, e.g., upper-percentile exposures may result mostly from occupational exposure, while lower percentile exposures arise from general environmental sources. Both VOC emissions aggregated at the national level and VOC concentrations measured in ambient air also have declined substantially over the study period and are supportive of the exposure trends, although the NHANES data suggest the importance of indoor sources and personal activities on VOC exposures. While piecewise QR models suggest that exposures of several VOCs decreased little or any during the 1990's, followed by more rapid decreases from 1999 to 2004, questions are raised concerning the reliability of VOC data in several of the NHANES cohorts and its applicability as an exposure indicator, as demonstrated by the modest correlation between VOC levels in blood and personal air

  10. Exposure-response functions for health effects of air pollutants based on epidemiological findings

    Energy Technology Data Exchange (ETDEWEB)

    Aunan, K

    1995-10-01

    The objective of this report is to provide exposure-response functions for health effects and air pollution, which can be used in cost-effectiveness analyses of abatement measures. When cost-effective abatement strategies for air pollution are analyzed, and when air quality standards are set, it is important to have quantitative knowledge about health damage. In spite of their shortcomings, epidemiological studies provide a sound basis for exposure-response functions because they involve a random cross section of the population. In this report the exposure-response functions apply to the relation between air pollutant concentrations and relative effect frequencies, and involve the following health effect end-points: acute and chronic respiratory symptoms in children and adults, asthma episodes in children and adults, eye irritations, headache, lung damage in children, excess mortality, lung cancer incidence. The effects are attributed to one indicator component, which in many cases is particles, but for some effects NO{sub 2}, SO{sub 2}, O{sub 3}, or CO. A calculation procedure is suggested which makes it possible to estimate excess annual symptom-days for short-term effects using the annual average concentration. 103 refs., 1 table

  11. Effect of standards on new equipment design by new international standards and industry restraints

    Science.gov (United States)

    Endelman, Lincoln L.

    1991-01-01

    The use of international standards to further trade is one of the objectives of creating a standard. By having form fit and function compatible the free interchange of manufactured goods can be handled without hindrance. Unfortunately by setting up standards that are peculiar to a particular country or district it is possible to exclude competition from a group of manufacturers. A major effort is now underway to develop international laser standards. In the May I 990 issue of Laser Focus World Donald R. Johnson the director of industrial technology services for the National Institute of Standards and Technology (NIST formerly the National Bureau of Standards) is quoted as follows: " The common means of protectionism has been through certification for the market place. " The article goes on to say " Mr. Johnson expects this tradition to continue and that the new European Community (EC) will demand not just safety standards but performance standards as well. . . . the American laser industry must move very quickly on this issue or risk being left behind the European standards bandwagon. " The article continues laser companies must get involved in the actual standards negotiating process if they are to have a say in future policy. A single set of standards would reduce the need to repeatedly recalibrate products for different national markets. " As a member of ISO TC-72 SC9 I am

  12. Development of personnel exposure management system with personal computer

    International Nuclear Information System (INIS)

    Yamato, Ichiro; Yamamoto, Toshiki

    1992-01-01

    In nuclear power plants, large scale personnel exposure management systems have been developed and established by utilities. Though being common in the base, the implementations are specific by plants. Contractors must control their workers' exposures by their own methods and systems. To comply with the utilities' parental systems, contractors' systems tend to differ by plants, thus make it difficult for contractors to design a standard system that is common to all relevant plants. Circumstances being as such, however, we have developed a system which is applicable to various customer utilities with minimal variations, using personal computers with database management and data communication softwares, with relatively low cost. We hope that this system will develop to the standard model for all Japanese contractors' personnel exposure management systems. (author)

  13. Prenatal cigarette smoke exposure: Pregnancy outcome and gestational changes in plasma nicotine concentration, hematocrit, and carboxyhemoglobin in a newly standardized rat model

    International Nuclear Information System (INIS)

    Farkas, Svetlana; Hussein, Jabeen; Ariano, Robert E.; Sitar, Daniel S.; Hasan, Shabih U.

    2006-01-01

    Epidemiological studies support an association between perinatal cigarette smoke (CS) exposure and a number of severe pre- and postnatal complications. However, the mechanisms through which CS enhances such risks largely remain unknown. One of the reasons for our inability to discover such mechanisms has been the unavailability of a clinically relevant and physiologically concordant animal model. A number of studies have previously used nicotine (Nic) as surrogate for CS. We sought to (1) establish the amount of CS exposure to achieve plasma Nic concentrations observed among moderate to heavy smokers (20-60 ng/ml) (2) investigate the temporal changes in plasma Nic concentrations, carboxyhemoglobin, and hematocrit with advancing pregnancy, and (3) elucidate the effects of CS exposure on pregnancy outcome. Pregnant Sprague-Dawley rats were exposed to various doses of CS or room air (Sham) from days 6 to 21 of gestation. Exposure to 6000 ml/day of CS led to very high plasma Nic concentrations and increased maternal and fetal mortality (P < 0.001). The plasma Nic concentrations remained higher than those observed in moderate smokers until the CS dose was reduced to 1000 ml/day and showed dose-dependent temporal changes with advancing gestational age. Significant increases in carboxyhemoglobin and hematocrit were observed in the CS group as compared with the Sham group (P < 0.001). In addition, prenatally CS exposed fetuses had lower birth weight as compared with the Sham group (P = 0.04). Our current study establishes a newly standardized and physiologically relevant model to investigate the mechanisms of CS-mediated adverse effects during the critical period of fetal development

  14. Performance standards of road safety management

    Directory of Open Access Journals (Sweden)

    Čabarkapa Milenko R.

    2016-01-01

    Full Text Available Road safety management controlling means the process of finding out the information whether the road safety is improving in a measure to achieve the objectives. The process of control consists of three basic elements: definition of performances and standards, measurement of current performances and comparison with the set standards, and improvement of current performances, if they deviate from the set standards. The performance standards of road safety management system are focused on a performances measurement, in terms of their design and characteristics, in order to support the performances improvement of road safety system and thus, ultimately, improve the road safety. Defining the performance standards of road safety management system, except that determines the design of the system for performances measurement, directly sets requirements whose fulfillment will produce a road safety improvement. The road safety management system, based on the performance standards of road safety, with a focus on results, will produce the continuous improvement of road safety, achieving the long-term 'vision zero', the philosophy of road safety, that human life and health take priority over mobility and other traffic objectives of the road traffic.

  15. Realistic evaluation of tester exposure based on Florida testing experience

    International Nuclear Information System (INIS)

    Schreiber, R.A.

    1990-01-01

    This paper reports on a radon decay product exposure model for Florida Certified Radon Measurement Technicians that has been formulated based on the guidance of 10CFR20. This model was used to estimate the exposure of 44 Florida measurement technicians from January through November of 1989. Comparing estimated testing and home exposure shows that 100% of the technicians observed received more exposure in the home than during testing activities. Exposure during normal office hours also exceed testing exposure in 86% of the technicians observed. Health and safety exposure data for radon measurement technicians does not follow the standard concepts of occupational radiation exposure normally accepted in 10CFR20

  16. Providing the Missing Link: the Exposure Science Ontology ExO

    Science.gov (United States)

    Although knowledge-discovery tools are new to the exposure science community, these tools are critical for leveraging exposure information to design health studies and interpret results for improved public health decisions. Standardized ontologies define relationships, allow for ...

  17. Interim report on the National Bureau of Standards/Bureau of Radiological Health 60Co teletherapy survey

    International Nuclear Information System (INIS)

    Thompson, D.L.; Wyckoff, H.O.; Soares, C.G.

    1978-01-01

    During the past three years the National Bureau of Standards and the Bureau of Radiological Health have been conducting a survey of 60 Co teletherapy facilities to determine their accuracy in exposing a phantom to a prescribed dose. As of May 1977, some 700 units were surveyed of the approximately 1000 which are licensed to administer therapy in the United States. Preliminary data indicate that about two-thirds of the respondents were able to calculate the specified 300 rad dose within 5 rad, while 8% reported values which varied from the specified dose by more than 15 rad. The mean exposure determined for a set of dosimeters differed from the 300 rad value by less than 5% for 83% of units; 4% of the units produced an exposure which differed by more than 10% of the target value

  18. Leveraging Standards to Promote Program Quality

    Science.gov (United States)

    Young, Michelle D.; Mawhinney, Hanna; Reed, Cynthia J.

    2016-01-01

    Standards provide a foundation for thinking about leadership development and practice. This article explores three sets of standards that impact educational leadership preparation: (a) the recently revised Interstate School Leaders Licensure Consortium (ISLLC) standards, which are now known as the Practice Standards for Educational Leaders (PSEL);…

  19. Assessing the Impact of Stricter Alcohol Advertising Standards: The Case of Beam Global Spirits.

    Science.gov (United States)

    Ross, Craig S; Sparks, Alicia; Jernigan, David H

    2016-08-01

    Reducing youth exposure to alcohol advertising is a global health priority. In most countries around the world, the alcohol industry is given the opportunity to regulate itself with respect to advertising practices. Generally, the alcohol industry self-regulations are lax, allowing youth to be disproportionately exposed to alcohol advertising. However, Beam Global Spirits and Wine (Beam) voluntarily adopted more restrictive advertising standards in the United States in 2007. This study assessed Beam's compliance with their new standard and estimates its effect on youth exposure and advertising costs. We found that Beam's compliance with its more restrictive standards was imperfect, but never-the-less, we estimated that youth exposure to alcohol advertising was reduced compared to other spirits brands. Beam's more restrictive standards did not increase their advertising costs and therefore other alcohol companies should consider adopting similar standards around the world.

  20. Simulated Prism Therapy in Virtual Reality produces larger after-effects than standard prism exposure in normal healthy subject - Implications for Neglect Therapy

    DEFF Research Database (Denmark)

    Wilms, Inge Linda

    2018-01-01

    BACKGROUND: Virtual reality is an important area of exploration within computer-based cognitive rehabilitation of visual neglect. Virtual reality will allow for closer monitoring of patient behaviour during prism adaptation therapy and perhaps change the way we induce prismatic after......-effects. OBJECTIVE: This study compares the effect of two different prism simulation conditions in virtual reality to a standard exposure to prism goggles after one session of Prism Adaptation Therapy in healthy subjects. METHOD: 20 healthy subjects were subjected to one session of prism adaptation therapy under...... training for rehabilitation of hemi spatial attentional deficits such as visual neglect....

  1. [Schools, office buildings, leisure settings: diversity of indoor air quality issues. Global review on indoor air quality in these settings].

    Science.gov (United States)

    Mandin, C; Derbez, M; Kirchner, S

    2012-07-01

    This review provides a global overview of indoor air quality issues in schools, office buildings and recreational settings. It presents the most recent scientific publications and the on-going work conducted in France in the frame of the indoor air quality Observatory. Monitoring campaigns on indoor air quality in schools have been carried out in the recent years in Europe. However, few studies have specifically addressed the role of exposure in these buildings on children's health. Indoor air quality in office buildings has been little studied so far. However, some specificities, such as emissions from electronic devices, frequent cleaning, impossibility to open windows in high-rise buildings, for example, should be examined and their role on the health and comfort studied. Finally, even if the time spent in recreational settings is short, the quality of indoor air should also be considered because of specific pollution. This is the case of indoor swimming pools (exposure to chlorination byproducts) and ice-rinks (exposure to exhaust from machines used to smooth the ice). Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  2. Development of fusion safety standards

    International Nuclear Information System (INIS)

    Longhurst, G.R.; Petti, D.A.; Dinneen, G.A.; Herring, J.S.; DeLooper, J.; Levine, J.D.; Gouge, M.J.

    1996-01-01

    Two new U.S. Department of Energy (DOE) standards have been prepared to assist in the design and regulation of magnetic fusion facilities. They are DOE-STD-6002-96, 'Safety of Magnetic Fusion Facilities - Requirements,' and DOE-STD-6003-96 'Safety of Magnetic Fusion Facilities - Guidance.' The first standard sets forth requirements, mostly based on the Code of Federal Regulations, deemed necessary for the safe design and operation of fusion facilities and a set of safety principles to use in the design. The second standard provides guidance on how to meet the requirements identified in DOE-STD-6002-96. It is written specifically for a facility such as the International Thermonuclear Experimental Reactor (ITER) in the DOE regulatory environment. As technical standards, they are applicable only to the extent that compliance with these standards is included in the contracts of the developers. 7 refs., 1 fig

  3. An update on standards for radiation in the environment and associated estimates of risk

    International Nuclear Information System (INIS)

    Kocher, D.C.

    1989-01-01

    This presentation reviews current and proposed standards, recommendations, and guidances for limiting routine radiation exposures of the public, and estimates the risk corresponding to standards, recommendations, and guidances. These estimates provide a common basis for comparing different criteria for limiting public exposures to radiation, as well as hazardous chemicals

  4. A probabilistic assessment of health risks associated with short-term exposure to tropospheric ozone

    Energy Technology Data Exchange (ETDEWEB)

    Whitfield, R.G; Biller, W.F.; Jusko, M.J.; Keisler, J.M.

    1996-06-01

    The work described in this report is part of a larger risk assessment sponsored by the U.S. Environmental Protection Agency. Earlier efforts developed exposure-response relationships for acute health effects among populations engaged in heavy exertion. Those efforts also developed a probabilistic national ambient air quality standards exposure model and a general methodology for integrating probabilistic exposure-response relation- ships and exposure estimates to calculate overall risk results. Recently published data make it possible to model additional health endpoints (for exposure at moderate exertion), including hospital admissions. New air quality and exposure estimates for alternative national ambient air quality standards for ozone are combined with exposure-response models to produce the risk results for hospital admissions and acute health effects. Sample results explain the methodology and introduce risk output formats.

  5. Risk assessment and management of radiofrequency radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Dabala, Dana [Railways Medical Clinic Cluj-Napoca, Occupational Medicine Department, 16-20 Bilascu Gheorghe St., 400015 Cluj-Napoca (Romania); Surducan, Emanoil; Surducan, Vasile; Neamtu, Camelia [National Institute for Research and Development of Isotopic and Molecular Technologies, 65-103 Donath St., 400293 Cluj-Napoca (Romania)

    2013-11-13

    Radiofrequency radiation (RFR) industry managers, occupational physicians, security department, and other practitioners must be advised on the basic of biophysics and the health effects of RF electromagnetic fields so as to guide the management of exposure. Information on biophysics of RFR and biological/heath effects is derived from standard texts, literature and clinical experiences. Emergency treatment and ongoing care is outlined, with clinical approach integrating the circumstances of exposure and the patient's symptoms. Experimental risk assessment model in RFR chronic exposure is proposed. Planning for assessment and monitoring exposure, ongoing care, safety measures and work protection are outlining the proper management.

  6. Risk assessment and management of radiofrequency radiation exposure

    International Nuclear Information System (INIS)

    Dabala, Dana; Surducan, Emanoil; Surducan, Vasile; Neamtu, Camelia

    2013-01-01

    Radiofrequency radiation (RFR) industry managers, occupational physicians, security department, and other practitioners must be advised on the basic of biophysics and the health effects of RF electromagnetic fields so as to guide the management of exposure. Information on biophysics of RFR and biological/heath effects is derived from standard texts, literature and clinical experiences. Emergency treatment and ongoing care is outlined, with clinical approach integrating the circumstances of exposure and the patient's symptoms. Experimental risk assessment model in RFR chronic exposure is proposed. Planning for assessment and monitoring exposure, ongoing care, safety measures and work protection are outlining the proper management

  7. Microstructural evolution and mechanical properties of Inconel 718 after thermal exposure

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Z.S., E-mail: yuzaisong@tpri.com.cn [State Key Laboratory for Mechanical Behavior of Materials, Xi’an Jiaotong University, No. 28, Xianning West Road, Xi’an 710049 (China); Xi' an Thermal Power Research Institute Co. Ltd., No. 136, Xingqing Road, Xi’an 710032 (China); Zhang, J.X. [State Key Laboratory for Mechanical Behavior of Materials, Xi’an Jiaotong University, No. 28, Xianning West Road, Xi’an 710049 (China); Yuan, Y.; Zhou, R.C.; Zhang, H.J.; Wang, H.Z. [Xi' an Thermal Power Research Institute Co. Ltd., No. 136, Xingqing Road, Xi’an 710032 (China)

    2015-05-14

    Inconel 718 was subjected to various heat treatments, i.e., solution heat treatment, standard ageing treatment and standard ageing plus 700 °C thermal exposure. The mechanical properties of the alloys were determined using tensile tests and Charpy pendulum impact tests at 650 °C and room temperature, respectively. The highest yield strength of 988 MPa was attained in the standard aged specimen, whereas a maximum impact toughness of 217 J cm{sup −2} was attained in the solution-treated specimen. After thermal exposure, the mechanical properties of the specimens degrade. Both the yield strength and impact toughness decreased monotonically with increasing thermal exposure time. Subjected to a 10000-h long-term thermal exposure, the yield strength dramatically decreased to 475 MPa (almost 50% of the maximum strength), and the impact toughness reduced to only 18 J cm{sup −2}. The microstructures of the specimens were characterized using scanning electron microscopy (SEM) and transmission electron microscopy (TEM). Coarsening of γ′ and γ″ and the transformation of γ″ to δ-Ni{sub 3}Nb was observed after thermal exposure. However, a complete transformation from metastable γ″ to δ-Ni{sub 3}Nb was never accomplished, even after the 10000-h long-term thermal exposure. Based on the obtained experimental results, the effects of the microstructural evolution on the mechanical properties are discussed.

  8. Development of a new fuzzy exposure model

    International Nuclear Information System (INIS)

    Vasconcelos, Wagner Eustaquio de; Lira, Carlos Alberto Brayner de Oliveira; Texeira, Marcello Goulart

    2007-01-01

    The main topic of this study is the development of an exposure fuzzy model to evaluate the exposure of inhabitants in an area containing uranium, which present a high natural background. In this work, a fuzzy model was created, based on some of the following main factors: activity concentration of uranium, physiological factors and characteristic customs of the exposed individuals. An inference block was created to evaluate some factors of radiation exposure. For this, AHP-fuzzy technique (Analytic Hierarchic Process) was used and its application was demonstrated for a subjected population to the radiation of the natural uranium. The Mandami type fuzzy model was also created from the opinion of specialists. The Monte Carlo method was used to generate a statistics of input data and the daily average exposure served as comparison parameter between the three techniques. The output fuzzy sets were expressed in form of linguistic variables, such as high, medium and low. In the qualitative analysis, the obtained results were satisfactory when translating the opinion of the specialists. In the quantitative analysis, the obtained values are part of the same fuzzy set as the values found in literature. The global results suggest that this type of fuzzy model is highly promising for analysis of exposure to ionizing radiation. (author)

  9. Development of a new fuzzy exposure model

    Energy Technology Data Exchange (ETDEWEB)

    Vasconcelos, Wagner Eustaquio de; Lira, Carlos Alberto Brayner de Oliveira [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear. Grupo de Engenharia de Reatores], E-mail: wagner@ufpe.br, E-mail: cabol@ufpe.br; Texeira, Marcello Goulart [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Terrestrial Modelling Group], E-mail: marcellogt@ime.eb.br

    2007-07-01

    The main topic of this study is the development of an exposure fuzzy model to evaluate the exposure of inhabitants in an area containing uranium, which present a high natural background. In this work, a fuzzy model was created, based on some of the following main factors: activity concentration of uranium, physiological factors and characteristic customs of the exposed individuals. An inference block was created to evaluate some factors of radiation exposure. For this, AHP-fuzzy technique (Analytic Hierarchic Process) was used and its application was demonstrated for a subjected population to the radiation of the natural uranium. The Mandami type fuzzy model was also created from the opinion of specialists. The Monte Carlo method was used to generate a statistics of input data and the daily average exposure served as comparison parameter between the three techniques. The output fuzzy sets were expressed in form of linguistic variables, such as high, medium and low. In the qualitative analysis, the obtained results were satisfactory when translating the opinion of the specialists. In the quantitative analysis, the obtained values are part of the same fuzzy set as the values found in literature. The global results suggest that this type of fuzzy model is highly promising for analysis of exposure to ionizing radiation. (author)

  10. Single exposure simultaneous acquisition of digital and conventional radiographs utilizing unaltered dose

    International Nuclear Information System (INIS)

    Oestmann, J.W.; Greene, R.

    1988-01-01

    We describe the simultaneous acquisition of digital and conventional radiographs with a single standard radiographic exposure. A digitizable storage phosphor (ST Imaging Plate, Fuji) is sandwiched into a radiographic cassette (X-Omatic, Kodak) behind a conventional radiographic film-screen combination (Lanex medium screens, OC film, Kodak). The barium fluorohalide storage phosphor is digitized with a helium-neon laser scanner (TCR 201, Toshiba), and the conventional radiograph is processed in the standard fashion (M7B, Kodak). The storage phosphor is exposed by the 'wasted' radiation normally exiting the back of the film-screen combination (32% of the cassette entrance dose at 141 kVp). At a standard exposure (6.3 mAs), the conventional radiograph is of unaltered quality, and the digital image appears to have an adequate signal-to-noise ratio for chest studies despite the lower exposure dose. This technique produces twin images of identical spatial and temporal registration and avoids the added radiation exposure normally required to carry out comparative studies. (orig.)

  11. Adherence to Pre-Exposure Prophylaxis for HIV Prevention in a Clinical Setting.

    Directory of Open Access Journals (Sweden)

    Madeline C Montgomery

    Full Text Available The HIV epidemic in the United States (US disproportionately affects gay, bisexual, and other men who have sex with men (MSM. Pre-exposure prophylaxis (PrEP using co-formulated tenofovir disoproxil fumarate (TDF and emtricitabine (FTC has demonstrated high efficacy in reducing HIV incidence among MSM. However, low adherence was reported in major efficacy trials and may present a substantial barrier to successful PrEP implementation. Rates of adherence to PrEP in "real-world" clinical settings in the US remain largely unknown.We reviewed demographic and clinical data for the first 50 patients to enroll in a clinical PrEP program in Providence, Rhode Island. We analyzed self-reported drug adherence as well as drug concentrations in dried blood spots (DBS from patients who attended either a three- or six-month follow-up appointment. We further assessed drug concentrations and the resistance profile of a single patient who seroconverted while taking PrEP.Of the first 50 patients to be prescribed PrEP, 62% attended a follow-up appointment at three months and 38% at six months. Of those who attended an appointment at either time point (70%, n = 35, 92% and 95% reported taking ±4 doses/week at three and six months, respectively. Drug concentrations were performed on a random sample of 20 of the 35 patients who attended a follow-up appointment. TDF levels consistent with ±4 doses/week were found in 90% of these patients. There was a significant correlation between self-reported adherence and drug concentrations (r = 0.49, p = 0.02. One patient who had been prescribed PrEP seroconverted at his three-month follow-up visit. The patient's drug concentrations were consistent with daily dosing. Population sequencing and ultrasensitive allele-specific PCR detected the M184V mutation, but no other TDF- or FTC-associated mutations, including those present as minor variants.In this clinical PrEP program, adherence was high, and self-reported drug adherence

  12. Adherence to Pre-Exposure Prophylaxis for HIV Prevention in a Clinical Setting.

    Science.gov (United States)

    Montgomery, Madeline C; Oldenburg, Catherine E; Nunn, Amy S; Mena, Leandro; Anderson, Peter; Liegler, Teri; Mayer, Kenneth H; Patel, Rupa; Almonte, Alexi; Chan, Philip A

    2016-01-01

    The HIV epidemic in the United States (US) disproportionately affects gay, bisexual, and other men who have sex with men (MSM). Pre-exposure prophylaxis (PrEP) using co-formulated tenofovir disoproxil fumarate (TDF) and emtricitabine (FTC) has demonstrated high efficacy in reducing HIV incidence among MSM. However, low adherence was reported in major efficacy trials and may present a substantial barrier to successful PrEP implementation. Rates of adherence to PrEP in "real-world" clinical settings in the US remain largely unknown. We reviewed demographic and clinical data for the first 50 patients to enroll in a clinical PrEP program in Providence, Rhode Island. We analyzed self-reported drug adherence as well as drug concentrations in dried blood spots (DBS) from patients who attended either a three- or six-month follow-up appointment. We further assessed drug concentrations and the resistance profile of a single patient who seroconverted while taking PrEP. Of the first 50 patients to be prescribed PrEP, 62% attended a follow-up appointment at three months and 38% at six months. Of those who attended an appointment at either time point (70%, n = 35), 92% and 95% reported taking ±4 doses/week at three and six months, respectively. Drug concentrations were performed on a random sample of 20 of the 35 patients who attended a follow-up appointment. TDF levels consistent with ±4 doses/week were found in 90% of these patients. There was a significant correlation between self-reported adherence and drug concentrations (r = 0.49, p = 0.02). One patient who had been prescribed PrEP seroconverted at his three-month follow-up visit. The patient's drug concentrations were consistent with daily dosing. Population sequencing and ultrasensitive allele-specific PCR detected the M184V mutation, but no other TDF- or FTC-associated mutations, including those present as minor variants. In this clinical PrEP program, adherence was high, and self-reported drug adherence accurately

  13. Rules and recent trends for setting health-based occupational exposure limits for chemicals

    Directory of Open Access Journals (Sweden)

    Jolanta Skowroń

    2015-04-01

    Full Text Available The working environment is the special case of the non-natural environment created by man in which the increased production activity brings about the concentration of stimulators particularly aggressive to the human organism, such as chemical hazards, noise, vibration, extreme temperatures, and finally, intensified psychological and emotional stress. Depending on the nature and intensity, working environment factors have been classified into dangerous, harmful and annoying. The workers are more and more frequently exposed to dangerous chemicals in the working environment. The chemicals cause many diseases including, in the 1st place, respiratory insufficiency, inflammatory skin conditions, psychoneurological disorders and neoplastic diseases. Occupational exposure limit values (OELs, the main criteria for occupational exposure assessment, constitute an important factor for the safe use of chemicals in the working environment. In Poland, to date there are 524 chemical substances and 19 dusts for which maximum admissible concentrations (MAC have been established.

  14. Radiation exposure with the NOMAD portable X-ray system.

    Science.gov (United States)

    Goren, A D; Bonvento, M; Biernacki, J; Colosi, D C

    2008-02-01

    A new hand-held battery-operated portable X-ray system was tested for possible leakage radiation through the existing heavy metal compounds surrounding the X-ray tube, backscatter radiation through the lead-filled acrylic shield attached at the end of the exit tube and patient exposure. Dose measurements were conducted using a DXTRR phantom and a water phantom. All measurements were recorded using calibrated thermoluminescent dosimetry (TLD), calibrated Unfors Model 583L dosemeter, and a calibrated Radcal MDH model 1015 dosemeter. The settings for all exposure were 60 kVp, 2.3 mA and 0.25 s using Kodak Insight (Class F) film. All backscatter measurements, in front of the shield, behind the shield, at the finger of the operator, the operator's chest, eyes and gonads were significantly below the maximum permissible radiation leakage as per the United States Food and Drug Administration regulations (100 mR h(-1)). Our measurements indicate that the exposure would be well within the occupational maximum permissible dose for an occupationally exposed person. Film dose was consistent with the manufacturer's recommendations. As a result of our measurements, the State of New York Bureau of Environmental Radiation Protection granted us a variance to use the NOMAD on a case-by-case basis. Our data have shown that the NOMAD presents risks that are no greater than with standard dental radiographic units to the patient or operator and the measured doses are well below recommended levels.

  15. Electromagnetic field standards in Central and Eastern European countries: current state and stipulations for international harmonization.

    Science.gov (United States)

    Gajsek, P; Pakhomov, A G; Klauenberg, B J

    2002-04-01

    Electromagnetic field standards in the West are based on well-established acute biological effects that could be considered as signaling a potentially adverse health effect. The specific absorption rate, which is proportional to the tissue heating (thermal effects), represents the basic restriction of exposure to Radio-Frequency (RF) fields. On the other hand, Eastern European standards are designed to protect from potential non-thermal effects that might be caused by chronic exposure to very low intensities, where a so-called "power load" (a product of field intensity and duration of exposure) represents the basic limitation. Thus, electromagnetic field standards in Eastern European countries differ considerably from those which are proposed by the International Commission of Non-ionizing Radiation Protection and the Standards Coordinating Committee 28 of the Institute of Electrical and Electronics Engineers, Inc. In the present paper, the strategies for development of exposure limit values in electromagnetic fields standards currently in force in Eastern and Central European countries are discussed. Some differences as well as similarities of the national health and safety standards and the main obstacles to harmonization of these standards with those being established by Western national and international organizations and agencies are presented.

  16. Interaction of dental pulp stem cells with Biodentine and MTA after exposure to different environments

    Directory of Open Access Journals (Sweden)

    Anastasia Agrafioti

    Full Text Available ABSTRACT Objective: The aim of the present study was to evaluate and compare the cytotoxic effects of Biodentine and MTA on dental pulp stem cells (DPSCs and to assess cell viability and adherence after material exposure to an acidic environment. Material and Methods: DPSCs were cultured either alone or in contact with either: Biodentine; MTA set for 1 hour; or MTA set for 24 hours. After 4 and 7 days, cell viability was measured using the MTT assay. Biodentine and MTA were also prepared and packed into standardized bovine dentin disks and divided into three groups according to the storage media (n=6/group: freshly mixed materials without storage medium (Group A; materials stored in saline (Group B; materials stored in citric acid buffered at pH 5.4 (Group C. After 24 hours, DPSCs were introduced in the wells and cell adherence, viability, and cellular morphology were observed via confocal microscopy after three days of culture. Cell viability was analyzed using repeated-measures analysis of variance test with Tukey's post hoc tests (α=0.05. Results: Biodentine expressed significantly higher cell viability compared with all other groups after 4 days, with no differences after 7 days. Notably, cell viability was significantly greater in 24-hour set MTA compared with 1-hour set MTA and control groups after 7 days. Material exposure to an acidic environment showed an increase in cell adherence and viability in both groups. Conclusions: Biodentine induced a significantly accelerated cell proliferation compared with MTA. Setting of these materials in the presence of citric acid enhanced DPSC viability and adherence.

  17. Standards for radiology interpretation and reporting in the emergency setting

    International Nuclear Information System (INIS)

    Berlin, Leonard

    2008-01-01

    The radiologist plays a pivotal role in the medical management of injury and illness in both adults and children in the emergency setting. Although the primary role of the radiologist is to assist in establishing a correct diagnosis, the radiologist's responsibility goes well beyond simple detection and documentation. Communication is fundamental in assuring delivery of quality and safe health care. Lines of communication are most easily recognized between the radiologist and the patient's health-care provider (e.g., emergency department physician), but they are also becoming increasingly important between the radiologist and the patient. Radiologists must be familiar with both local and national practice guidelines related to the care of the patient in the emergency setting, in relation to both construction of the radiology report and appropriate communication of the results of radiologic studies. Familiarity with these aspects of the radiologists' responsibilities maximizes the chance of successful outcomes and minimizes the frequency of (and liability for) malpractice. (orig.)

  18. Completing the Link between Exposure Science and Toxicology for Improved Environmental Health Decision Making: The Aggregate Exposure Pathway Framework.

    Science.gov (United States)

    Teeguarden, Justin G; Tan, Yu-Mei; Edwards, Stephen W; Leonard, Jeremy A; Anderson, Kim A; Corley, Richard A; Kile, Molly L; Simonich, Staci M; Stone, David; Tanguay, Robert L; Waters, Katrina M; Harper, Stacey L; Williams, David E

    2016-05-03

    Driven by major scientific advances in analytical methods, biomonitoring, computation, and a newly articulated vision for a greater impact in public health, the field of exposure science is undergoing a rapid transition from a field of observation to a field of prediction. Deployment of an organizational and predictive framework for exposure science analogous to the "systems approaches" used in the biological sciences is a necessary step in this evolution. Here we propose the aggregate exposure pathway (AEP) concept as the natural and complementary companion in the exposure sciences to the adverse outcome pathway (AOP) concept in the toxicological sciences. Aggregate exposure pathways offer an intuitive framework to organize exposure data within individual units of prediction common to the field, setting the stage for exposure forecasting. Looking farther ahead, we envision direct linkages between aggregate exposure pathways and adverse outcome pathways, completing the source to outcome continuum for more meaningful integration of exposure assessment and hazard identification. Together, the two frameworks form and inform a decision-making framework with the flexibility for risk-based, hazard-based, or exposure-based decision making.

  19. Virtual reality exposure therapy for anxiety disorders: the state of the art

    NARCIS (Netherlands)

    Meyerbröker, K.; Emmelkamp, P.M.G.; Brahnam, S.; Jain, L.C.

    2011-01-01

    In the past 10 years virtual reality exposure therapy (VRET) has become a viable alternative for exposure in vivo, the gold standard for the treatment of anxiety disorders. VRET is often regarded as a natural extension of the systematic exposure component of (cognitive) behavior therapy. The

  20. Development of exposure scenarios for CERCLA risk assessments at the Savannah River Site

    International Nuclear Information System (INIS)

    Nix, D.W.; Immel, J.W.; Phifer, M.A.

    1992-01-01

    A CERCLA Baseline Risk Assessment (BRA) is performed to determine if there are any potential risks to human health and the environment from waste unit at SRS. The SRS has numerous waste units to evaluate in the RFMU and CMS/FS programs and, in order to provide a consistent approach, four standard exposure scenarios were developed for exposure assessments to be used in human health risk assessments. The standard exposure scenarios are divided into two temporal categories: (a) Current Land Use in the BRA, and (b) Future Land Use in the RERA. The Current Land Use scenarios consist of the evaluation of human health risk for Industrial Exposure (of a worker not involved in waste unit characterization or remediation), a Trespasser, a hypothetical current On-site Resident, and an Off-site Resident. The Future Land Use scenario considers exposure to an On-site Resident following termination of institutional control in the absence of any remedial action (No Action Alternative), as well as evaluating potential remedial alternatives against the four scenarios from the BRA. A critical facet in the development of a BRA or RERA is the scoping of exposure scenarios that reflect actual conditions at a waste unit, rather than using factors such as EPA Standard Default Exposure Scenarios (OSWER Directive 9285.6-03) that are based on upper-bound exposures that tend to reflect worst case conditions. The use of site-specific information for developing risk assessment exposure scenarios will result in a more realistic estimate of Reasonable Maximum Exposure for SRS waste units

  1. Development of exposure scenarios for CERCLA risk assessments at the Savannah River Site

    Energy Technology Data Exchange (ETDEWEB)

    Nix, D.W.; Immel, J.W. [Westinghouse Savannah River Co., Aiken, SC (United States); Phifer, M.A. [Tennessee Univ., Knoxville, TN (United States). Dept. of Civil Engineering

    1992-12-31

    A CERCLA Baseline Risk Assessment (BRA) is performed to determine if there are any potential risks to human health and the environment from waste unit at SRS. The SRS has numerous waste units to evaluate in the RFMU and CMS/FS programs and, in order to provide a consistent approach, four standard exposure scenarios were developed for exposure assessments to be used in human health risk assessments. The standard exposure scenarios are divided into two temporal categories: (a) Current Land Use in the BRA, and (b) Future Land Use in the RERA. The Current Land Use scenarios consist of the evaluation of human health risk for Industrial Exposure (of a worker not involved in waste unit characterization or remediation), a Trespasser, a hypothetical current On-site Resident, and an Off-site Resident. The Future Land Use scenario considers exposure to an On-site Resident following termination of institutional control in the absence of any remedial action (No Action Alternative), as well as evaluating potential remedial alternatives against the four scenarios from the BRA. A critical facet in the development of a BRA or RERA is the scoping of exposure scenarios that reflect actual conditions at a waste unit, rather than using factors such as EPA Standard Default Exposure Scenarios (OSWER Directive 9285.6-03) that are based on upper-bound exposures that tend to reflect worst case conditions. The use of site-specific information for developing risk assessment exposure scenarios will result in a more realistic estimate of Reasonable Maximum Exposure for SRS waste units.

  2. A multi-metric assessment of environmental contaminant exposure and effects in an urbanized reach of the Charles River near Watertown, Massachusetts

    Science.gov (United States)

    Smith, Stephen B.; Anderson, Patrick J.; Baumann, Paul C.; DeWeese, Lawrence R.; Goodbred, Steven L.; Coyle, James J.; Smith, David S.

    2012-01-01

    The Charles River Project provided an opportunity to simultaneously deploy a combination of biomonitoring techniques routinely used by the U.S. Geological Survey National Water Quality Assessment Program, the Biomonitoring of Environmental Status and Trends Project, and the Contaminant Biology Program at an urban site suspected to be contaminated with polycyclic aromatic hydrocarbons. In addition to these standardized methods, additional techniques were used to further elucidate contaminant exposure and potential impacts of exposure on biota. The purpose of the study was to generate a comprehensive, multi-metric data set to support assessment of contaminant exposure and effects at the site. Furthermore, the data set could be assessed to determine the relative performance of the standardized method suites typically used by the National Water Quality Assessment Program and the Biomonitoring of Environmental Status and Trends Project, as well as the additional biomonitoring methods used in the study to demonstrate ecological effects of contaminant exposure. The Contaminant Effects Workgroup, an advisory committee of the U.S. Geological Survey/Contaminant Biology Program, identified polycyclic aromatic hydrocarbons as the contaminant class of greatest concern in urban streams of all sizes. The reach of the Charles River near Watertown, Massachusetts, was selected as the site for this study based on the suspected presence of polycyclic aromatic hydrocarbon contamination and the presence of common carp (Cyprinus carpio), largemouth bass (Micropterus salmoides), and white sucker (Catostomus commersoni). All of these fish have extensive contaminant-exposure profiles related to polycyclic aromatic hydrocarbons and other environmental contaminants. This project represented a collaboration of universities, Department of the Interior bureaus including multiple components of the USGS (Biological Resources Discipline and Water Resources Discipline Science Centers, the

  3. Occupational Exposure to Diesel Particulate Matter in Municipal Household Waste Workers.

    Science.gov (United States)

    Lee, Kyong-Hui; Jung, Hye-Jung; Park, Dong-Uk; Ryu, Seung-Hun; Kim, Boowook; Ha, Kwon-Chul; Kim, Seungwon; Yi, Gwangyong; Yoon, Chungsik

    2015-01-01

    The purposes of this study were to determine the following: 1) the exposure levels of municipal household waste (MHW) workers to diesel particulate matter (DPM) using elemental carbon (EC), organic carbon (OC), total carbon (TC), black carbon (BC), and fine particulate matter (PM 2.5) as indicators; 2) the correlations among the indicators; 3) the optimal indicator for DPM; and 4) factors that influence personal exposure to DPM. A total of 72 workers in five MHW collection companies were assessed over a period of 7 days from June to September 2014. Respirable EC/OC samples were quantified using the thermal optical transmittance method. BC and PM 2.5 were measured using real-time monitors, an aethalometer and a laser photometer. All results were statistically analyzed for occupational and environmental variables to identify the exposure determinants of DPM. The geometric mean of EC, OC, TC, BC and PM 2.5 concentrations were 4.8, 39.6, 44.8, 9.1 and 62.0 μg/m3, respectively. EC concentrations were significantly correlated with the concentrations of OC, TC and BC, but not with those of PM 2.5. The exposures of the MHW collectors to EC, OC, and TC were higher than those of the drivers (pemission standard had higher exposures to EC, OC, TC and PM 2.5 than those working on Euro 4 trucks (pemission standard, and average driving speed were the most influential factors in determining worker exposure. We assessed MHW workers' exposure to DPM using parallel sampling of five possible indicators. Of these five indicators, EC was shown to be the most useful indicator of DPM exposure for MHW workers, and the job task, European emission standard, and average driving speed were the main determinants of EC exposure.

  4. Telemetry Standards, Part 1

    Science.gov (United States)

    2015-07-01

    IMAGE FRAME RATE (R-x\\ IFR -n) PRE-TRIGGER FRAMES (R-x\\PTG-n) TOTAL FRAMES (R-x\\TOTF-n) EXPOSURE TIME (R-x\\EXP-n) SENSOR ROTATION (R-x...0” (Single frame). “1” (Multi-frame). “2” (Continuous). Allowed when: When R\\CDT is “IMGIN” IMAGE FRAME RATE R-x\\ IFR -n R/R Ch 10 Status: RO...the settings that the user wishes to modify. Return Value The impact : A partial IHAL <configuration> element containing only the new settings for

  5. Assessment of occupational exposure due to intakes of radionuclides. Safety guide

    International Nuclear Information System (INIS)

    2004-01-01

    Occupational exposure due to radioactive materials can occur as a result of various human activities. These include work associated with the different stages of the nuclear fuel cycle, the use of radioactive sources in medicine, scientific research, agriculture and industry, and occupations which involve the handling of materials containing enhanced concentrations of naturally occurring radionuclides. In order to control this exposure, it is necessary to be able to assess the magnitude of the doses involved. Three interrelated Safety Guides, prepared jointly by the IAEA and the International Labour Office (ILO), provide guidance on the application of the requirements of the Basic Safety Standards with respect to occupational exposure. Reference [3] gives general advice on the exposure conditions for which monitoring programmes should be set up to assess radiation doses arising from external radiation and from intakes of radionuclides by workers. More specific guidance on the assessment of doses from external sources of radiation can be found in Ref. [4] and the present Safety Guide deals with intakes of radioactive materials. Recommendations related to occupational radiation protection have also been developed by the International Commission on Radiological Protection (ICRP) [5]. These and other current recommendations of the ICRP [6] have been taken into account in preparing this Safety Guide. The purpose of this Safety Guide is to provide guidance for regulatory authorities on conducting assessments of intakes of radioactive material arising from occupational exposure. This Guide will also be useful to those concerned with the planning, management and operation of occupational monitoring programmes, and to those involved in the design of equipment for use in internal dosimetry and workplace monitoring

  6. Assessment of occupational exposure due to intakes of radionuclides. Safety guide

    International Nuclear Information System (INIS)

    2000-01-01

    Occupational exposure due to radioactive materials can occur as a result of various human activities. These include work associated with the different stages of the nuclear fuel cycle, the use of radioactive sources in medicine, scientific research, agriculture and industry, and occupations which involve the handling of materials containing enhanced concentrations of naturally occurring radionuclides. In order to control this exposure, it is necessary to be able to assess the magnitude of the doses involved. Three interrelated Safety Guides, prepared jointly by the IAEA and the International Labour Office (ILO), provide guidance on the application of the requirements of the Basic Safety Standards with respect to occupational exposure. Reference [3] gives general advice on the exposure conditions for which monitoring programmes should be set up to assess radiation doses arising from external radiation and from intakes of radionuclides by workers. More specific guidance on the assessment of doses from external sources of radiation can be found in Ref. [4] and the present Safety Guide deals with intakes of radioactive materials. Recommendations related to occupational radiation protection have also been developed by the International Commission on Radiological Protection (ICRP) [5]. These and other current recommendations of the ICRP [6] have been taken into account in preparing this Safety Guide. The purpose of this Safety Guide is to provide guidance for regulatory authorities on conducting assessments of intakes of radioactive material arising from occupational exposure. This Guide will also be useful to those concerned with the planning, management and operation of occupational monitoring programmes, and to those involved in the design of equipment for use in internal dosimetry and workplace monitoring

  7. Assessment of occupational exposure due to intakes of radionuclides. Safety guide

    International Nuclear Information System (INIS)

    2001-01-01

    Occupational exposure due to radioactive materials can occur as a result of various human activities. These include work associated with the different stages of the nuclear fuel cycle, the use of radioactive sources in medicine, scientific research, agriculture and industry, and occupations which involve the handling of materials containing enhanced concentrations of naturally occurring radionuclides. In order to control this exposure, it is necessary to be able to assess the magnitude of the doses involved. Three interrelated Safety Guides, prepared jointly by the IAEA and the International Labour Office (ILO), provide guidance on the application of the requirements of the Basic Safety Standards with respect to occupational exposure. Reference [3] gives general advice on the exposure conditions for which monitoring programmes should be set up to assess radiation doses arising from external radiation and from intakes of radionuclides by workers. More specific guidance on the assessment of doses from external sources of radiation can be found in Ref. [4] and the present Safety Guide deals with intakes of radioactive materials. Recommendations related to occupational radiation protection have also been developed by the International Commission on Radiological Protection (ICRP) [5]. These and other current recommendations of the ICRP [6] have been taken into account in preparing this Safety Guide. The purpose of this Safety Guide is to provide guidance for regulatory authorities on conducting assessments of intakes of radioactive material arising from occupational exposure. This Guide will also be useful to those concerned with the planning, management and operation of occupational monitoring programmes, and to those involved in the design of equipment for use in internal dosimetry and workplace monitoring

  8. Assessment of occupational exposure due to intakes of radionuclides. Safety guide

    International Nuclear Information System (INIS)

    2002-01-01

    Occupational exposure due to radioactive materials can occur as a result of various human activities. These include work associated with the different stages of the nuclear fuel cycle, the use of radioactive sources in medicine, scientific research, agriculture and industry, and occupations which involve the handling of materials containing enhanced concentrations of naturally occurring radionuclides. In order to control this exposure, it is necessary to be able to assess the magnitude of the doses involved. Three interrelated Safety Guides, prepared jointly by the IAEA and the International Labour Office (ILO), provide guidance on the application of the requirements of the Basic Safety Standards with respect to occupational exposure. Reference [3] gives general advice on the exposure conditions for which monitoring programmes should be set up to assess radiation doses arising from external radiation and from intakes of radionuclides by workers. More specific guidance on the assessment of doses from external sources of radiation can be found in Ref. [4] and the present Safety Guide deals with intakes of radioactive materials. Recommendations related to occupational radiation protection have also been developed by the International Commission on Radiological Protection (ICRP) [5]. These and other current recommendations of the ICRP [6] have been taken into account in preparing this Safety Guide. The purpose of this Safety Guide is to provide guidance for regulatory authorities on conducting assessments of intakes of radioactive material arising from occupational exposure. This Guide will also be useful to those concerned with the planning, management and operation of occupational monitoring programmes, and to those involved in the design of equipment for use in internal dosimetry and workplace monitoring

  9. Assessment of occupational exposure due to intakes of radionuclides. Safety guide

    International Nuclear Information System (INIS)

    1999-01-01

    Occupational exposure due to radioactive materials can occur as a result of various human activities. These include work associated with the different stages of the nuclear fuel cycle, the use of radioactive sources in medicine, scientific research, agriculture and industry, and occupations which involve the handling of materials containing enhanced concentrations of naturally occurring radionuclides. In order to control this exposure, it is necessary to be able to assess the magnitude of the doses involved. Three interrelated Safety Guides, prepared jointly by the IAEA and the International Labour Office (ILO), provide guidance on the application of the requirements of the Basic Safety Standards with respect to occupational exposure. Reference [3] gives general advice on the exposure conditions for which monitoring programmes should be set up to assess radiation doses arising from external radiation and from intakes of radionuclides by workers. More specific guidance on the assessment of doses from external sources of radiation can be found in Ref. [4] and the present Safety Guide deals with intakes of radioactive materials. Recommendations related to occupational radiation protection have also been developed by the International Commission on Radiological Protection (ICRP) [5]. These and other current recommendations of the ICRP [6] have been taken into account in preparing this Safety Guide. The purpose of this Safety Guide is to provide guidance for regulatory authorities on conducting assessments of intakes of radioactive material arising from occupational exposure. This Guide will also be useful to those concerned with the planning, management and operation of occupational monitoring programmes, and to those involved in the design of equipment for use in internal dosimetry and workplace monitoring

  10. Clustering of Sun Exposure Measurements

    DEFF Research Database (Denmark)

    Have, Anna Szynkowiak; Larsen, Jan; Hansen, Lars Kai

    2002-01-01

    In a medically motivated Sun-exposure study, questionnaires concerning Sun-habits were collected from a number of subjects together with UV radiation measurements. This paper focuses on identifying clusters in the heterogeneous set of data for the purpose of understanding possible relations between...... Sun-habits exposure and eventually assessing the risk of skin cancer. A general probabilistic framework originally developed for text and Web mining is demonstrated to be useful for clustering of behavioral data. The framework combines principal component subspace projection with probabilistic...

  11. Rules and recent trends for setting health-based occupational exposure limits for chemicals.

    Science.gov (United States)

    Skowroń, Jolanta; Czerczak, Sławomir

    2015-01-01

    The working environment is the special case of the non-natural environment created by man in which the increased production activity brings about the concentration of stimulators particularly aggressive to the human organism, such as chemical hazards, noise, vibration, extreme temperatures, and finally, intensified psychological and emotional stress. Depending on the nature and intensity, working environment factors have been classified into dangerous, harmful and annoying. The workers are more and more frequently exposed to dangerous chemicals in the working environment. The chemicals cause many diseases including, in the 1st place, respiratory insufficiency, inflammatory skin conditions, psychoneurological disorders and neoplastic diseases. Occupational exposure limit values (OELs), the main criteria for occupational exposure assessment, constitute an important factor for the safe use of chemicals in the working environment. In Poland, to date there are 524 chemical substances and 19 dusts for which maximum admissible concentrations (MAC) have been established. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  12. A set of dosimetry systems for electron beam irradiation

    International Nuclear Information System (INIS)

    Lin Min; Lin Jingwen; Chen Yundong; Li Huazhi; Xiao Zhenhong; Gao Juncheng

    1999-01-01

    To follow the rapid development of radiation processing with electron beams, it is urgent to set up a set of dosimetric standards to provide Quality Assurance (QA) of electron beam irradiation and unify the values of the quality of the absorbed dose measurements for electron beams. This report introduces a set of dosimetry systems established in Radiometrology Center of China Institute of Atomic Energy (RCCIAE), which have been or will be used as dosimetric standards in the Nuclear Industry System (NIS) in China. For instance, the potassium (silver) dichromate and ceric-cerous sulfate dosimetry systems will be used as standard dosimeters, while alanine-ESR dosimetry system as a transfer dosimeter, and FJL-01 CTA as a routine dosimeter. (author)

  13. Human response to combined indoor environment exposures

    DEFF Research Database (Denmark)

    Toftum, Jørn

    2002-01-01

    Most thermal comfort standards and guidelines presume sedentary, light activity and a neutral overall thermal sensation when predicting local thermal discomfort. In addition, current standards specify criteria for separate aspects of the indoor environment, e.g. thermal climate, air quality...... or noise, with only little consideration of possible interactions between the different types of exposure. The studies summarized in this article found a clear impact of activity and overall thermal sensation on human sensitivity to air movement, whereas no interaction effects of exposure to several local...... thermal discomfort factors were observed. Limited evidence was found of significant interactions between different aspects of the indoor environment. Only for the effect of air temperature and air humidity on sensory air quality were well-estabished relationships available....

  14. Infrared skin damage thresholds from 1319-nm continuous-wave laser exposures

    Science.gov (United States)

    Oliver, Jeffrey W.; Vincelette, Rebecca; Noojin, Gary D.; Clark, Clifton D.; Harbert, Corey A.; Schuster, Kurt J.; Shingledecker, Aurora D.; Kumru, Semih S.; Maughan, Justin; Kitzis, Naomi; Buffington, Gavin D.; Stolarski, David J.; Thomas, Robert J.

    2013-12-01

    A series of experiments were conducted in vivo using Yucatan miniature pigs (Sus scrofa domestica) to determine thermal damage thresholds to the skin from 1319-nm continuous-wave Nd:YAG laser irradiation. Experiments employed exposure durations of 0.25, 1.0, 2.5, and 10 s and beam diameters of ˜0.6 and 1 cm. Thermal imagery data provided a time-dependent surface temperature response from the laser. A damage endpoint of fifty percent probability of a minimally visible effect was used to determine threshold for damage at 1 and 24 h postexposure. Predicted thermal response and damage thresholds are compared with a numerical model of optical-thermal interaction. Resultant trends with respect to exposure duration and beam diameter are compared with current standardized exposure limits for laser safety. Mathematical modeling agreed well with experimental data, predicting that though laser safety standards are sufficient for exposures <10 s, they may become less safe for very long exposures.

  15. Environmental radiation protection standards

    International Nuclear Information System (INIS)

    Richings, L.D.G.; Morley, F.; Kelley, G.N.

    1978-04-01

    The principles involved in the setting of radiological protection standards are reviewed, and the differences in procedures used by various countries in implementing them are outlined. Standards are taken here to mean the specific numerical limits relating to radiation doses to people or to amounts of radioactive material released into the environment. (author)

  16. Patient radiation exposure during pediatric cardiac catheterization

    International Nuclear Information System (INIS)

    Fellows, K.E.; Leibovic, S.J.

    1983-01-01

    Exposure air product (EAP) and center field entrance exposure (free-in-air) were measured in seventeen pediatric patients undergoing cardiac catheterization. Exposures were recorded separately for biplane fluoroscopy and cine angiocardiography using flat-plate ionization chambers. In the posterior-anterior (PA) projections, median EAP was 425 Roentgen-square centimeter (R-cm 2 ), with a range of 90.5-3,882 R-cm 2 ; 29-35% of this exposure occurred during cine filming. In the lateral projection, median EAP was 276 R-cm 2 (range 117-1,173); 52-59% of this exposure was due to cine filming. Median center field entrance exposure in the PA view was 7.86 Roentgens (R) with a range 2.16-73.9 of and in the lateral projection 7.39 R (range 2.64-24.6). As much as 25% of the exposure from the entire examination was contributed by manual ''test'' exposures to set cine radiographic kVp. We recommend use of testing circuits, which determine cine radiographic factors automatically and thus should lower levels of exposure

  17. Patient radiation exposure during pediatric cardiac catheterization

    International Nuclear Information System (INIS)

    Fellows, K.E.; Leibovic, S.J.

    1983-01-01

    Exposure are product (EAP) and center field entrance exposure (free-in-air) were measured in seventeen pediatric patients undergoing cardiac catheterization. Exposures were recorded separately for biplane fluoroscopy and cine angiocardiography using flat-plate ionization chambers. In the posterior-anterior (PA) projections, median EAP was 425 Roentgen-square centimeter (R-cm 2 ), with a range of 90.5-3,882 R-cm 2 ; 29-35% of this exposure occurred during cine filming. In the lateral projection, median EAP was 276 R-cm 2 (range 117-1,173); 52-59% of this exposure was due to cine filming. Median center field entrance exposure in the PA view was 7.86 Roentgens (R) with a range 2.16-73.9 of and in the lateral projection 7.39 R (range 2.64-24.6). As much as 25% of the exposure from the entire examination was contributed by manual ''test'' exposures to set cine radiographic kVp. We recommend use of testing circuits, which determine cine radiographic factors automatically and thus should lower levels of exposure. (orig.)

  18. Exposure to Interpersonal Violence and Socioemotional Adjustment in Economically Disadvantaged Preschoolers

    Science.gov (United States)

    Bush, Hillary H.; Eisenhower, Abbey

    2014-01-01

    Focusing specifically on the experiences of economically disadvantaged preschoolers, the relations between interpersonal violence exposure, behavior problems, and social skills were examined in both the home and school settings. In this racially and ethnically diverse sample of preschoolers from poor, urban households (N = 64; 3-6 years old; 56% female), many children (33%) had been exposed to at least one type of interpersonal violence, and even more (70%) had been exposed to any type of potentially traumatic event (PTE). Although exposure to interpersonal violence was not directly associated with parent- or teacher-reported behavior problems or social skills, a significant interaction effect was observed between exposure to interpersonal violence and teacher-reported internalizing problems in predicting teacher-reported social skills; specifically, for children with the highest levels of internalizing problems, a positive relation between interpersonal violence exposure and social skills was observed. This indirect effect was observed only in the school setting, whereas children in this high-risk sample appeared to demonstrate resilience in the home setting. Given these high rates of exposure, additional, clinically-relevant research is needed to inform interventions for this vulnerable population. PMID:25175528

  19. Development of a Job-Exposure Matrix (AsbJEM) to Estimate Occupational Exposure to Asbestos in Australia.

    Science.gov (United States)

    van Oyen, Svein C; Peters, Susan; Alfonso, Helman; Fritschi, Lin; de Klerk, Nicholas H; Reid, Alison; Franklin, Peter; Gordon, Len; Benke, Geza; Musk, Arthur W

    2015-07-01

    Occupational exposure data on asbestos are limited and poorly integrated in Australia so that estimates of disease risk and attribution of disease causation are usually calculated from data that are not specific for local conditions. To develop a job-exposure matrix (AsbJEM) to estimate occupational asbestos exposure levels in Australia, making optimal use of the available exposure data. A dossier of all available exposure data in Australia and information on industry practices and controls was provided to an expert panel consisting of three local industrial hygienists with thorough knowledge of local and international work practices. The expert panel estimated asbestos exposures for combinations of occupation, industry, and time period. Intensity and frequency grades were estimated to enable the calculation of annual exposure levels for each occupation-industry combination for each time period. Two indicators of asbestos exposure intensity (mode and peak) were used to account for different patterns of exposure between occupations. Additionally, the probable type of asbestos fibre was determined for each situation. Asbestos exposures were estimated for 537 combinations of 224 occupations and 60 industries for four time periods (1943-1966; 1967-1986; 1987-2003; ≥2004). Workers in the asbestos manufacturing, shipyard, and insulation industries were estimated to have had the highest average exposures. Up until 1986, 46 occupation-industry combinations were estimated to have had exposures exceeding the current Australian exposure standard of 0.1 f ml(-1). Over 90% of exposed occupations were considered to have had exposure to a mixture of asbestos varieties including crocidolite. The AsbJEM provides empirically based quantified estimates of asbestos exposure levels for Australian jobs since 1943. This exposure assessment application will contribute to improved understanding and prediction of asbestos-related diseases and attribution of disease causation. © The

  20. Americans' Average Radiation Exposure

    International Nuclear Information System (INIS)

    2000-01-01

    We live with radiation every day. We receive radiation exposures from cosmic rays, from outer space, from radon gas, and from other naturally radioactive elements in the earth. This is called natural background radiation. It includes the radiation we get from plants, animals, and from our own bodies. We also are exposed to man-made sources of radiation, including medical and dental treatments, television sets and emission from coal-fired power plants. Generally, radiation exposures from man-made sources are only a fraction of those received from natural sources. One exception is high exposures used by doctors to treat cancer patients. Each year in the United States, the average dose to people from natural and man-made radiation sources is about 360 millirem. A millirem is an extremely tiny amount of energy absorbed by tissues in the body