WorldWideScience

Sample records for serum urine saliva

  1. Cortisol in urine and saliva

    DEFF Research Database (Denmark)

    Hurwitz Eller, N; Netterstrøm, B; Hansen, Åse Marie

    2001-01-01

    The objective of the study was to analyse the relations between excretion of cortisol in urine and saliva and the intima media thickness (IMT) of the artery carotis communis.......The objective of the study was to analyse the relations between excretion of cortisol in urine and saliva and the intima media thickness (IMT) of the artery carotis communis....

  2. Rapid determination of recent cocaine use with magnetic particles-based enzyme immunoassays in serum, saliva, and urine fluids.

    Science.gov (United States)

    Vidal, Juan C; Bertolín, Juan R; Bonel, Laura; Asturias, Laura; Arcos-Martínez, M Julia; Castillo, Juan R

    2016-06-05

    Cocaine is one of the most worldwide used illicit drugs. We report a magnetic particles-based enzyme-linked immunoassay (mpEIA) method for the rapid and sensitive determination of cocaine (COC) in saliva, urine and serum samples. Under optimized conditions, the limits of detections were 0.09ngmL(-1) (urine), 0.15ngmL(-1) (saliva), and 0.06ngmL(-1) COC (human serum). Sensitivities were in the range EC50=0.6-2.5ngmL(-1) COC. The cross-reactivity with the principal metabolite benzoylecgonine (BZE) was only 1.6%. Recovering percentages of doped samples (0, 10, 50, and 100ngmL(-1) of COC) ranged from about 86-111%. Some advantages of the developed mpEIA over conventional ELISA kits are faster incubations, improved reproducibility, and consumption of lower amounts of antibody and enzyme conjugates due to the use of magnetic beads. The reported method was validated following the guidelines on bioanalytical methods of the European Medicines Agency (2011). Unmetabolized COC detection has a great interest in pharmacological, pharmacokinetics, and toxicokinetics studies, and can be used to detect a very recent COC use (1-6h). Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Nicotine concentrations in urine and saliva of smokers and non-smokers.

    Science.gov (United States)

    Feyerabend, C; Higenbottam, T; Russell, M A

    1982-01-01

    Nicotine concentrations were measured in saliva and urine samples collected from 82 smokers and 56 non-smokers after a morning at work. Each subject answered a series of questions related to their recent intentional or passive exposure to tobacco smoke. All non-smokers had measurable amounts of nicotine in both saliva and urine. Those non-smokers who reported recent exposure to tobacco smoke had significantly higher nicotine concentrations (p less than 0.001) than those who had not been exposed; their concentrations overlapped those of smokers who had smoked up to three cigarettes before sampling had the greatest influence on nicotine concentrations (r=0.62 for saliva and r=0.51 for urine). Neither the nicotine for yield of cigarettes nor the self-reported degree of inhalation had any significant effect on nicotine concentrations. PMID:6802384

  4. Estimation of Cutoff Values of Cotinine in Urine and Saliva for Pregnant Women in Poland

    Directory of Open Access Journals (Sweden)

    Joanna Stragierowicz

    2013-01-01

    Full Text Available Setting appropriate cutoff values and the use of a highly sensitive analytical method allow for correct classification of the smoking status. Urine-saliva pairs samples of pregnant women in the second and third trimester, and saliva only in the first trimester were collected. Offline SPE and LC-ESI-MS/MS method was developed in the broad concentration range (saliva 0.4–1000 ng/mL, urine 0.8–4000 ng/mL. The mean recoveries were 3.7±7.6% for urine and 99.1±2.6% for saliva. LOD for saliva was 0.12 ng/mL and for urine 0.05 ng/mL; LOQ was 0.4 ng/mL and 0.8 ng/mL, respectively. Intraday and interday precision equaled, respectively, 1.2% and 3.4% for urine, and 2.3% and 6.4% for saliva. There was a strong correlation between salivary cotinine and the uncorrected cotinine concentration in urine in the second and third trimesters of pregnancy. The cutoff values were established for saliva 12.9 ng/mL and urine 42.3 ng/mL or 53.1 μg/g creatinine with the ROC curve analysis. The developed analytical method was successfully applied to quantify cotinine, and a significant correlation between the urinary and salivary cotinine levels was found. The presented cut-off values for salivary and urinary cotinine ensure a categorization of the smoking status among pregnant women that is more accurate than self-reporting.

  5. Isolation of Infective Zika Virus from Urine and Saliva of Patients in Brazil

    Science.gov (United States)

    da Silva, Kely A. B.; de Castro, Marcia G.; Gerber, Alexandra L.; de Almeida, Luiz G. P.; Lourenço-de-Oliveira, Ricardo; Vasconcelos, Ana Tereza R.

    2016-01-01

    Background Zika virus (ZIKV) is an emergent threat provoking a worldwide explosive outbreak. Since January 2015, 41 countries reported autochthonous cases. In Brazil, an increase in Guillain-Barré syndrome and microcephaly cases was linked to ZIKV infections. A recent report describing low experimental transmission efficiency of its main putative vector, Ae. aegypti, in conjunction with apparent sexual transmission notifications, prompted the investigation of other potential sources of viral dissemination. Urine and saliva have been previously established as useful tools in ZIKV diagnosis. Here, we described the presence and isolation of infectious ZIKV particles from saliva and urine of acute phase patients in the Rio de Janeiro state, Brazil. Methodology/Principal Findings Nine urine and five saliva samples from nine patients from Rio de Janeiro presenting rash and other typical Zika acute phase symptoms were inoculated in Vero cell culture and submitted to specific ZIKV RNA detection and quantification through, respectively, NAT-Zika, RT-PCR and RT-qPCR. Two ZIKV isolates were achieved, one from urine and one from saliva specimens. ZIKV nucleic acid was identified by all methods in four patients. Whenever both urine and saliva samples were available from the same patient, urine viral loads were higher, corroborating the general sense that it is a better source for ZIKV molecular diagnostic. In spite of this, from the two isolated strains, each from one patient, only one derived from urine, suggesting that other factors, like the acidic nature of this fluid, might interfere with virion infectivity. The complete genome of both ZIKV isolates was obtained. Phylogenetic analysis revealed similarity with strains previously isolated during the South America outbreak. Conclusions/Significance The detection of infectious ZIKV particles in urine and saliva of patients during the acute phase may represent a critical factor in the spread of virus. The epidemiological

  6. Isolation of Infective Zika Virus from Urine and Saliva of Patients in Brazil.

    Directory of Open Access Journals (Sweden)

    Myrna C Bonaldo

    2016-06-01

    Full Text Available Zika virus (ZIKV is an emergent threat provoking a worldwide explosive outbreak. Since January 2015, 41 countries reported autochthonous cases. In Brazil, an increase in Guillain-Barré syndrome and microcephaly cases was linked to ZIKV infections. A recent report describing low experimental transmission efficiency of its main putative vector, Ae. aegypti, in conjunction with apparent sexual transmission notifications, prompted the investigation of other potential sources of viral dissemination. Urine and saliva have been previously established as useful tools in ZIKV diagnosis. Here, we described the presence and isolation of infectious ZIKV particles from saliva and urine of acute phase patients in the Rio de Janeiro state, Brazil.Nine urine and five saliva samples from nine patients from Rio de Janeiro presenting rash and other typical Zika acute phase symptoms were inoculated in Vero cell culture and submitted to specific ZIKV RNA detection and quantification through, respectively, NAT-Zika, RT-PCR and RT-qPCR. Two ZIKV isolates were achieved, one from urine and one from saliva specimens. ZIKV nucleic acid was identified by all methods in four patients. Whenever both urine and saliva samples were available from the same patient, urine viral loads were higher, corroborating the general sense that it is a better source for ZIKV molecular diagnostic. In spite of this, from the two isolated strains, each from one patient, only one derived from urine, suggesting that other factors, like the acidic nature of this fluid, might interfere with virion infectivity. The complete genome of both ZIKV isolates was obtained. Phylogenetic analysis revealed similarity with strains previously isolated during the South America outbreak.The detection of infectious ZIKV particles in urine and saliva of patients during the acute phase may represent a critical factor in the spread of virus. The epidemiological relevance of this finding, regarding the contribution

  7. SALIVA SEBAGAI UJI SARING OSTEOPOROSIS

    Directory of Open Access Journals (Sweden)

    Niniarty Z. Djamal

    2015-07-01

    Full Text Available Osteoporosis is a metabolic bone disease, and is characterized by low bone mass and microstructure deterioration of the bone, which leads to increased risk of fracture. Biomarker of bone metabolism can be seen as beginning of bone loss and first detection before imbalanced bone turnover comes. Biomarker of bone formation as serum bone alkaline fosfatase, osteocalcin (OC, procollagen type I, and biomarker of bone resorption as urine pyridinoline (Pyd and deoxypyridinoline (Dpd crosslinks, hydroxyprolin. The simultaneous examination of serum OC and urine Pyd or Dpd as a very good screening test for determination of bone imbalanced at the moment of the menopausal or the beginning of the pasca menopausal. Saliva as a potential diagnostic fluid for the assessment of osteoporosis biomarker concentrations. The study found elevated three classic warning signs for osteopororsis os OC, Dpd and 116 in the saliva of sheep without ovaries, which were similar to the levels of signs found in their blood and urine. Expectations, that the test may become available within five years and one day the test may be able to be performed at home like pregnancy test. Osteoporosis biomarker in saliva suggested detected of bone mass density easier. Beside that can be used as a method of early diagnostic and as a monitor therapy that as salinity of the examinations of bone mass on radiology.

  8. Saliva/serum ghrelin, obestatin and homocysteine levels in patients with ischaemic heart disease

    Science.gov (United States)

    Kilic, Nermin; Dagli, Necati; Aydin, Suleyman; Erman, Fazilet; Bek, Yuksel; Akin, Okhan; Kilic, SS; Erdemli, Haci Kemal; Alacam, Hasan

    2017-01-01

    Summary Background: We aimed to compare ghrelin, obestatin, homocysteine (Hcy), vitamin B12 and folate levels in the serum and saliva of ischaemic heart disease patients. Methods: Serum and saliva were collected from 33 ischaemic heart disease (IHD) patients and 28 age- and body mass index-matched healthy individuals. Levels of acylated and desacylated ghrelin, obestatin and Hcy were determined using the ELISA method. Results: Acylated ghrelin, desacylated ghrelin and obestatin levels in the saliva were found to be higher than those in the serum of the control group, while acylated and desacylated ghrelin levels in the saliva were significantly lower than those in the serum. Obestatin levels were higher in IHD patients (p = 0.001). Saliva and serum vitamin B12 and folate levels in IHD patients were significantly lower than in the control group (p = 0.001). Conclusions: It was determined that serum ghrelin levels increased in ischaemic heart disease patients, while serum levels of obestatin decreased. PMID:28759087

  9. Serum and saliva levels of cathepsin L in patients with acute coronary syndrome.

    Science.gov (United States)

    Mirzaii-Dizgah, Iraj; Riahi, Esmail

    2011-03-01

    Coronary artery disease (CAD) is the major cause of death nearly all over the world, and accurate and rapid diagnosis of CAD is of major medical and economic importance. The aim of this study was to evaluate the serum and saliva levels of cathepsin L in patients with acute coronary syndrome (ACS). In a cross-sectional study, 39 patients with ACS and 28 with controls were recruited to the study, and cathepsin L levels were measured in serum, resting saliva, and stimulated saliva obtained 12 and 24 h after the onset of ACS by ELISA method. Statistical analyses of Fisher's exact test, the Student's t-test or Kruskal-Wallis test were performed. Stimulated saliva cathepsin L levels in patients with ACS 12 hours but not 24 hours after admission showed significant decrease compared with that in control subjects. However, there were no significant differences in serum and unstimulated saliva cathepsin L levels between groups. Serum and saliva levels of cathepsin L remain unchanged in patients with ACS and hence may not be a promising factor in CAD risk assessment. It seems that serum and saliva cathepsin L may not be a good biomarker for CHD. CAD: Coronary artery disease, ACS: Acute coronary syndrome, CHD: Coronary heart disease, EU: Emergency unit, MI: Myocardial infarction. Cathepsin L, Acute coronary syndrome, Resting saliva, Stimulated saliva. How to cite this article: Mirzaii-Dizgah I, Riahi E. Serum and Saliva Levels of Cathepsin L in Patients with Acute Coronary Syndrome. J Contemp Dent Pract 2011;12(2):114-119.

  10. Realising the Potential of Urine and Saliva as Diagnostic Tools in Sport and Exercise Medicine.

    Science.gov (United States)

    Lindsay, Angus; Costello, Joseph T

    2017-01-01

    Accurate monitoring of homeostatic perturbations following various psychophysiological stressors is essential in sports and exercise medicine. Various biomarkers are routinely used as monitoring tools in both clinical and elite sport settings. Blood collection and muscle biopsies, both invasive in nature, are considered the gold standard for the analysis of these biomarkers in exercise science. Exploring non-invasive methods of collecting and analysing biomarkers that are capable of providing accurate information regarding exercise-induced physiological and psychological stress is of obvious practical importance. This review describes the potential benefits, and the limitations, of using saliva and urine to ascertain biomarkers capable of identifying important stressors that are routinely encountered before, during, or after intense or unaccustomed exercise, competition, over-training, and inappropriate recovery. In particular, we focus on urinary and saliva biomarkers that have previously been used to monitor muscle damage, inflammation, cardiovascular stress, oxidative stress, hydration status, and brain distress. Evidence is provided from a range of empirical studies suggesting that urine and saliva are both capable of identifying various stressors. Although additional research regarding the efficacy of using urine and/or saliva to indicate the severity of exercise-induced psychophysiological stress is required, it is likely that these non-invasive biomarkers will represent "the future" in sports and exercise medicine.

  11. The use of saliva as a practical and feasible alternative to urine in large-scale screening for congenital cytomegalovirus infection increasesinclusion and detection rates

    Directory of Open Access Journals (Sweden)

    Emanuelle Santos de Carvalho Cardoso

    2015-04-01

    Full Text Available INTRODUCTION: Although urine is considered the gold-standard material for the detection of congenital cytomegalovirus (CMV infection, it can be difficult to obtain in newborns. The aim of this study was to compare the efficiency of detection of congenital CMV infection in saliva and urine samples. METHODS: One thousand newborns were included in the study. Congenital cytomegalovirus deoxyribonucleic acid (DNA was detected by polymerase chain reaction (PCR. RESULTS: Saliva samples were obtained from all the newborns, whereas urine collection was successful in only 333 cases. There was no statistically significant difference between the use of saliva alone or saliva and urine collected simultaneously for the detection of CMV infection. CONCLUSIONS: Saliva samples can be used in large-scale neonatal screening for CMV infection.

  12. Biomonitorization of cadmium, chromium, manganese, nickel and lead in whole blood, urine, axillary hair and saliva in an occupationally exposed population

    Energy Technology Data Exchange (ETDEWEB)

    Gil Fernando, E-mail: fgil@ugr.es [Department of Legal Medicine and Toxicology, University of Granada, School of Medicine (Spain); Hernandez, Antonio F. [Department of Legal Medicine and Toxicology, University of Granada, School of Medicine (Spain); Marquez, Claudia [Internal Resident in Occupational Medicine, School of Occupational Medicine of University of Granada (Spain); Femia, Pedro [Department of Statistics, University of Granada, School of Medicine (Spain); Olmedo, Pablo; Lopez-Guarnido, Olga; Pla, Antonio [Department of Legal Medicine and Toxicology, University of Granada, School of Medicine (Spain)

    2011-02-15

    Heavy metal contamination from occupational origin is a cause for concern because of its potential accumulation in the environment and in living organisms leading to long term toxic effects. This study was aimed to assess Cd, Cr, Mn, Ni and Pb levels in whole blood, urine, axillary hair and saliva from 178 individuals with occupational exposure to heavy metals. Levels of metal compounds were determined by atomic absorption spectrometry. We collected information on occupation, lifestyle habits and food intake by questionnaire. Multiple linear regression analyses for metal ion concentration in whole blood, urine, axillary hair and saliva were adjusted for age, gender, smoking and alcohol consumption, lifetime workplace exposure, residence area and food habits. Overall, blood and urine median concentrations found for the five metals analyzed do not exceed biological exposure indexes, so that they are very similar to a non-occupationally exposed population. Toxicokinetic differences may account for the lack of correlations found for metal levels in hair and saliva with those in blood or urine. For those heavy metals showing higher median levels in blood with respect to hair (Cd, Mn and Pb) indicating lesser hair incorporation from blood, the lifetime working experience was inversely correlated with their hair levels. The longer the lifetime working experience in industrial environments, the higher the Mn and Ni concentration in saliva. Axillary hair and saliva may be used as additional and/or alternative samples to blood or urine for biomonitoring hair Mn, and saliva Ni in subjects with occupational exposure. - Research Highlights: {yields} Metal levels in workers were similar to an occupationally non-exposed population. {yields} Metal levels in blood and urine were below recommended reference values. {yields} A lack of correlation was observed between metal levels in blood and saliva. {yields} Toxicokinetic differences may account for the lack of correlations observed

  13. Metronidazole as a radiosensitizer: a preliminary report on estimation in serum and saliva

    International Nuclear Information System (INIS)

    Karim, A.B.M.F.; Faber, D.B.; Haas, R.E.; Hoekstra, F.H.; Njo, K.H.

    1980-01-01

    Some studies indicate the clinical benefit of hypoxic radiosensitizers in patients who are undergoing radiotherapy. Serum level of sensitizers are usualy advised; however they are very demanding on the patient. Saliva level of the sensitizers may be an alternative method. This study correlated serum level of metronidazole to the saliva level in 10 patients who were undergoing radiotherapy with the sensitizer. A change to the saliva level method appears to relieve the patients

  14. Determination of carbamazepine in serum and saliva samples by high performance liquid chromatography with ultraviolet detection.

    Science.gov (United States)

    Dordević, Snezana; Kilibarda, Vesna; Stojanović, Tomislav

    2009-05-01

    Carbamazepine is antiepileptic drug widely used for the treatment of epilepsy. Due to low therapeutic index of carbamazepine there is a need for routine measuring its concentrations in biological fluids. The aim of the study was to describe a method for concomitant determination of carbamazepine in the serum and saliva. Separation of the drug from matrix is achieved by reversed-phase chromatography on a C18 column, with a mobile phase of methanol-water-acetic acid (65:34:1) at a flow-rate of 1.0 ml/min. Detection was effected by ultra-violet absorption at 285 nm. The total run time was 5 min. Samples were prepared by alkaline extraction (pH 10) using chlorophorm. Calibration curves were in the range 0.1-5 microg/mL for serum and saliva samples. Mean recoveries of spiked serum and saliva were 97.59 and 92.30%, respectively. Limits of detection (LOD) of carbamazepine in serum and saliva were 0.166 and 0.178 microg/mL, respectively. Limits of quantification (LOQ) in the serum and saliva were 0.237 and 0.226 microg/mL, respectively. The method precision was carried out with coefficient of variation of 2.10% and 4.03% for the serum and saliva, respectively. The obtained data showed that there was a strong correlation between saliva and serum concentrations (r = 0.9481, p < 0.001). The method described here is rapid, precise, accurate and simple, and can be used for quantitative determination of carbamazepine in human serum and saliva after therapy applying. Saliva samples could be used as an alternative matrix for therapeutic drug monitoring of this antiepileptic drug.

  15. Therapeutic drug monitoring of caffeine in preterm infants: Could saliva be an alternative to serum?

    Science.gov (United States)

    Chaabane, Amel; Chioukh, Fatma Z; Chadli, Zohra; Ben Fredj, Nadia; Ben Ameur, Karim; Ben Hmida, Hayet; Boughattas, Naceur A; Monastiri, Kamel; Aouam, Karim

    2017-12-01

    Evaluate whether saliva could be a useful alternative to serum for routine therapeutic drug monitoring of caffeine in preterm infants using the enzyme multiplied immunoassay technique (EMIT) assay. We conducted a prospective study including preterm infants (less than 34 weeks' amenorrhea) admitted to the intensive care and neonatal medicine department. All infants received 5, 10, 15, 20 and 25mg/kg/day of citrate caffeine intravenously from the first to the fifth day of birth, respectively. For each patient, two concomitant blood and saliva samples corresponding to the trough concentrations were collected 24hours after each caffeine dose. The caffeine concentrations were determined using the EMIT ® 2000 caffeine assay. Thirteen preterm infants were included. The saliva and the serum caffeine concentration increased proportionally to the administered dose. Saliva and serum kinetics were comparable and the saliva caffeine concentrations were correlated to the serum ones (r 2 =0.76). Saliva caffeine monitoring by EMIT is a valid, useful and safe alternative to serum in preterm infants. Copyright © 2017 Société française de pharmacologie et de thérapeutique. Published by Elsevier Masson SAS. All rights reserved.

  16. Determination of carbamazepine in serum and saliva samples by high performance liquid chromatography with ultraviolet detection

    Directory of Open Access Journals (Sweden)

    Đorđević Snežana

    2009-01-01

    Full Text Available Background/Aim. Carbamazepine is antiepileptic drug widely used for the treatment of epilepsy. Due to low therapeutic index of carbamazepine there is a need for routine measuring its concentrations in biological fluids. The aim of the study was to describe a method for concomitant determination of carbamazepine in the serum and saliva. Methods. Separation of the drug from matrix is achieved by reversedphase chromatography on a C18 column, with a mobile phase of methanol-water-acetic acid (65:34:1 at a flow-rate of 1.0 ml/min. Detection was effected by ultra-violet absorption at 285 nm. The total run time was 5 min. Samples were prepared by alkaline extraction (pH 10 using chlorophorm. Results. Calibration curves were in the range 0.1-5 μg/mL for serum and saliva samples. Mean recoveries of spiked serum and saliva were 97.59 and 92.30%, respectively. Limits of detection (LOD of carbamazepine in serum and saliva were 0.166 and 0.178 μg/mL, respectively. Limits of quantification (LOQ in the serum and saliva were 0.237 and 0.226 μg/mL, respectively. The method precision was carried out with coefficient of variation of 2.10% and 4.03% for the serum and saliva, respectively. The obtained data showed that there was a strong correlation between saliva and serum concentrations (r = 0.9481, p < 0.001. Conclusion. The method described here is rapid, precise, accurate and simple, and can be used for quantitative determination of carbamazepine in human serum and saliva after therapy applying. Saliva samples could be used as an alternative matrix for therapeutic drug monitoring of this antiepileptic drug.

  17. Comparison between Serum and Saliva Biochemical Constituents in Dairy Cows during Lactation and Dry Period

    Directory of Open Access Journals (Sweden)

    Mahmoud R. Abd Ellah

    2015-07-01

    Full Text Available The present study was undertaken to compare serum and salivary biochemical constituents during lactation and dry period in dairy cows. Also, the present study evaluated for the first time the salivary biochemical constituents in dairy cows. The study was carried out using 45 healthy multiparous Holstein cows maintained in dairy farms located in Morioka city (Iwate prefecture, Japan. Cows were classified into groups based on the month of lactation. Serum, saliva and milk samples were collected and analyzed. Data were statistically analyzed and the variation in serum and salivary biochemical constituents during lactation and dry period were discussed. From the present study, it could be concluded that the 1st month of lactation has the highest levels for serum free fatty acids (FFA, β- Hydroxy butyric acid (BHBA and aceto Acetic acid (ACAC. The dry period has the highest serum glucose level and the lowest serum FFA, BHBA and aspartate aminotransferase levels. Both serum and salivary FFA showed the highest value during the 1st month of lactation. Saliva contains a high level of gamma glutamyl transferase. The level of ammonia in saliva is higher than its serum level during all months of lactation and dry period. Most of the biochemical constituents in saliva change in different way from serum during lactation and dry period. Milk protein/fat ratio of 0.7 may be not indicative for subclinical ketosis.

  18. Urine and serum fetuin-A levels in patients with urolithiasis.

    Science.gov (United States)

    Arora, Rajat; Abrol, Nitin; Antonisamy, B; Vanitha, S; Chandrasingh, J; Kumar, Santosh; Kekre, Nitin; Devasia, Antony

    2017-01-01

    Fetuin-A is a glycoprotein secreted by liver and has been shown to inhibit extraosseous mineralization. Urolithiasis may be a manifestation in the urinary tract due to fetuin deficiency in urine. The objective of this study was to compare the 24-h urine and serum fetuin-A levels of patients with and without urolithiasis. Serum and 24-h urine fetuin-A levels were measured in 41 patients with bilateral, multiple, or recurrent urinary tract calculi (Group A) and 41 matched controls with no calculi (Group B). Fetuin levels were measured by enzyme linked immunosorbent assay. Serum and urine fetuin-A levels in the two groups were compared. The median (range) 24-h urine fetuin-A value in Group A was 11.9 (1.12-221) mg/day and in Group B was 37.7 (1.28-125) mg/day. This difference was statistically significant (Mann-Whitney test, P = 0.0169). The median (range) serum fetuin-A in Group A was 0.67 (0.05-2.68) g/L and in Group B was 0.99 (0.01-5.5) g/L. The difference between serum values in the two arms was not statistically significant (Mann-Whitney test, P = 0.1817). However, the serum creatinine-adjusted mean log serum fetuin and urine fetuin were significantly different in the two arms ( P = 0.003). The mean ± standard deviation (range) serum creatinine in Group A was 0.98 ± 0.25 (0.56-1.58) mg% and in Group B was 0.83 ± 0.16 (0.58-1.18) mg% (two sample t -test, P = 0.0031). Patients with urolithiasis have lower urine fetuin-A and creatinine-adjusted serum fetuin-A levels.

  19. A Population Pharmacokinetic Model for Disposition in Plasma, Saliva and Urine of Scopolamine after Intranasal Administration to Healthy Human Subjects

    Science.gov (United States)

    Wu, L.; Tam, V. H.; Chow, D. S. L.; Putcha, L.

    2014-01-01

    An intranasal gel formulation of scopolamine (INSCOP) was developed for the treatment of Space Motion Sickness. The bioavailability and pharmacokinetics (PK) were evaluated under the Food and Drug Administration guidelines for clinical trials with an Investigative New Drug (IND) protocol. The aim of this project was to develop a PK model that can predict the relationship between plasma, saliva and urinary scopolamine concentrations using data collected from the IND clinical trials with INSCOP. Methods: Twelve healthy human subjects were administered three dose levels (0.1, 0.2 and 0.4 mg) of INSCOP. Serial blood, saliva and urine samples were collected between 5 min and 24 h after dosing and scopolamine concentrations were measured by using a validated LC-MS-MS assay. Pharmacokinetic Compartmental models, using actual dosing and sampling times, were built using Phoenix (version 1.2). Model selection was based on the likelihood ratio test on the difference of criteria (-2LL) and comparison of the quality of fit plots. Results: The best structural model for INSCOP (minimal -2LL= 502.8) was established. It consisted of one compartment each for plasma, saliva and urine, respectively, which were connected with linear transport processes except the nonlinear PK process from plasma to saliva compartment. The best-fit estimates of PK parameters from individual PK compartmental analysis and Population PK model analysis were shown in Tables 1 and 2, respectively. Conclusion: A population PK model that could predict population and individual PK of scopolamine in plasma, saliva and urine after dosing was developed and validated. Incorporating a non-linear transfer from plasma to saliva compartments resulted in a significantly improved model fitting. The model could be used to predict scopolamine plasma concentrations from salivary and urinary drug levels, allowing non-invasive therapeutic monitoring of scopolamine in space and other remote environments.

  20. Analysis of risperidone and 9-hydroxyrisperidone in human plasma, urine and saliva by MEPS-LC-UV.

    Science.gov (United States)

    Mandrioli, Roberto; Mercolini, Laura; Lateana, Domenico; Boncompagni, Giancarlo; Raggi, Maria Augusta

    2011-01-15

    Risperidone is currently one of the most frequently prescribed atypical antipsychotic drugs; its main active metabolite 9-hydroxyrisperidone contributes significantly to the therapeutic effects observed. An original analytical method is presented for the simultaneous analysis of risperidone and the metabolite in plasma, urine and saliva by high-performance liquid chromatography coupled to an original sample pre-treatment procedure based on micro-extraction by packed sorbent (MEPS). The assays were carried out using a C8 reversed-phase column and a mobile phase composed of 73% (v/v) acidic phosphate buffer (30 mM, pH 3.0) containing 0.23% triethylamine and 27% (v/v) acetonitrile. The UV detector was set at 238 nm and diphenhydramine was used as the internal standard. The sample pre-treatment by MEPS was carried out on a C8 sorbent. The extraction yields values were higher than 92% for risperidone and 90% for 9-hydroxyrisperidone, with RSD for precision always lower than 7.9% for both analytes. Limit of quantification values in the different matrices were 4 ng/mL or lower for risperidone and 6 ng/mL or lower for the metabolite. The method was successfully applied to plasma, urine and saliva samples from psychotic patients undergoing therapy with risperidone, with satisfactory accuracy results (recovery>89%) and no interference from other drugs. Thus, the method seems to be suitable for the therapeutic drug monitoring of schizophrenic patients using the three different biological matrices plasma, urine and saliva. Copyright © 2010 Elsevier B.V. All rights reserved.

  1. Validation of a method to quantify chromium, cadmium, manganese, nickel and lead in human whole blood, urine, saliva and hair samples by electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Olmedo, P.; Pla, A.; Hernandez, A.F.; Lopez-Guarnido, O.; Rodrigo, L. [Department of Legal Medicine and Toxicology, University of Granada, School of Medicine (Spain); Gil, F., E-mail: fgil@ugr.es [Department of Legal Medicine and Toxicology, University of Granada, School of Medicine (Spain)

    2010-02-05

    For biological monitoring of heavy metal exposure in occupational toxicology, usually whole blood and urine samples are the most widely used and accepted matrix to assess internal xenobiotic exposure. Hair samples and saliva are also of interest in occupational and environmental health surveys but procedures for the determination of metals in saliva and hair are very scarce and to our knowledge there is no validation of a method to quantify Cr, Cd, Mn, Ni and Pb in four different human biological materials (whole blood, urine, saliva and axilary hair) by electrothermal atomization atomic absorption spectrometry (ETAAS). In the present study, quantification methods for the determination of Cr, Cd, Mn, Ni and Pb in whole blood, urine, saliva and axilary hair were validated according to the EU common standards. Pyrolisis and atomization temperatures have been determined. The main parameters evaluated were: detection and quantification limits, linearity range, repeatability, reproducibility, recovery and uncertainty. Accuracy of the methods was tested with the whole blood, urine and hair certified reference materials and recoveries of the spiked samples were acceptable ranged from 96.3 to 107.8%.

  2. Validation of a method to quantify chromium, cadmium, manganese, nickel and lead in human whole blood, urine, saliva and hair samples by electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Olmedo, P.; Pla, A.; Hernandez, A.F.; Lopez-Guarnido, O.; Rodrigo, L.; Gil, F.

    2010-01-01

    For biological monitoring of heavy metal exposure in occupational toxicology, usually whole blood and urine samples are the most widely used and accepted matrix to assess internal xenobiotic exposure. Hair samples and saliva are also of interest in occupational and environmental health surveys but procedures for the determination of metals in saliva and hair are very scarce and to our knowledge there is no validation of a method to quantify Cr, Cd, Mn, Ni and Pb in four different human biological materials (whole blood, urine, saliva and axilary hair) by electrothermal atomization atomic absorption spectrometry (ETAAS). In the present study, quantification methods for the determination of Cr, Cd, Mn, Ni and Pb in whole blood, urine, saliva and axilary hair were validated according to the EU common standards. Pyrolisis and atomization temperatures have been determined. The main parameters evaluated were: detection and quantification limits, linearity range, repeatability, reproducibility, recovery and uncertainty. Accuracy of the methods was tested with the whole blood, urine and hair certified reference materials and recoveries of the spiked samples were acceptable ranged from 96.3 to 107.8%.

  3. Estimation of malondialdehyde levels in serum and saliva of children affected with sickle cell anemia

    Directory of Open Access Journals (Sweden)

    Sudhindra Baliga

    2018-01-01

    Full Text Available Background: Sickle cell anemia (SCA is an inherited disorder of hemoglobin synthesis characterized by deformed erythrocytes. Hemoglobin S present in sickle-shaped erythrocytes exhibits an enhanced rate of auto-oxidation compared with normal hemoglobin A. It produces more of reactive oxygen species (ROS which promotes oxidatively stressed environment. ROS degrade the membranes of sickle cell erythrocytes composed of polyunsaturated lipids and form malondialdehyde (MDA as a by-product. Aim: The aim of the study is to evaluate and compare the MDA levels of serum and saliva in SCA patients. Design: A total of 150 children aged 4–12 years were divided into two groups: Group A (n = 75 consisting of children suffering from SCA and Group B (n = 75 consisting of healthy children. Blood and saliva samples were collected aseptically from both the groups, and they were subjected to thiobarbituric acid assay. Absorbance was evaluated spectrophotometrically at 531 nm, and the values of concentration of MDA were derived. Results: The mean MDA levels in serum and saliva were 8.9825 ± 1.04 and 0.5152 ± 0.28, respectively, in Group A and they were found to be higher than mean MDA levels of serum (5.87 ± 0.92 and saliva (0.2929 ± 0.06 of Group B and the difference of their mean was found to be statistically significant. Conclusion: A significant correlation of the MDA was found in saliva and serum of the patients with SCA. This finding suggests that saliva can be effectively used as a noninvasive alternative for assessing the oxidative stress in patients with SCA.

  4. Metabolomic biomarkers in serum and urine in women with preeclampsia.

    Directory of Open Access Journals (Sweden)

    Marie Austdal

    Full Text Available To explore the potential of magnetic resonance (MR metabolomics for study of preeclampsia, for improved phenotyping and elucidating potential clues to etiology and pathogenesis.Urine and serum samples from pregnant women with preeclampsia (n = 10, normal pregnancies (n = 10 and non-pregnant women (n = 10 matched by age and gestational age were analyzed with MR spectroscopy and subjected to multivariate analysis. Metabolites were then quantified and compared between groups.Urine and serum samples revealed clear differences between women with preeclampsia and both control groups (normal pregnant and non-pregnant women. Nine urine metabolites were significantly different between preeclampsia and the normal pregnant group. Urine samples from women with early onset preeclampsia clustered together in the multivariate analysis. The preeclampsia serum spectra showed higher levels of low and very-low density lipoproteins and lower levels of high-density lipoproteins when compared to both non-pregnant and normal pregnant women.The MR determined metabolic profiles in urine and serum from women with preeclampsia are clearly different from normal pregnant women. The observed differences represent a potential to examine mechanisms underlying different preeclampsia phenotypes in urine and serum samples in larger studies. In addition, similarities between preeclampsia and cardiovascular disease in metabolomics are demonstrated.

  5. Serum and urine metabolomic fingerprinting in diagnostics of inflammatory bowel diseases.

    Science.gov (United States)

    Dawiskiba, Tomasz; Deja, Stanisław; Mulak, Agata; Ząbek, Adam; Jawień, Ewa; Pawełka, Dorota; Banasik, Mirosław; Mastalerz-Migas, Agnieszka; Balcerzak, Waldemar; Kaliszewski, Krzysztof; Skóra, Jan; Barć, Piotr; Korta, Krzysztof; Pormańczuk, Kornel; Szyber, Przemyslaw; Litarski, Adam; Młynarz, Piotr

    2014-01-07

    To evaluate the utility of serum and urine metabolomic analysis in diagnosing and monitoring of inflammatory bowel diseases (IBD). Serum and urine samples were collected from 24 patients with ulcerative colitis (UC), 19 patients with the Crohn's disease (CD) and 17 healthy controls. The activity of UC was assessed with the Simple Clinical Colitis Activity Index, while the activity of CD was determined using the Harvey-Bradshaw Index. The analysis of serum and urine samples was performed using proton nuclear magnetic resonance (NMR) spectroscopy. All spectra were exported to Matlab for preprocessing which resulted in two data matrixes for serum and urine. Prior to the chemometric analysis, both data sets were unit variance scaled. The differences in metabolite fingerprints were assessed using partial least-squares-discriminant analysis (PLS-DA). Receiver operating characteristic curves and area under curves were used to evaluate the quality and prediction performance of the obtained PLS-DA models. Metabolites responsible for separation in models were tested using STATISTICA 10 with the Mann-Whitney-Wilcoxon test and the Student's t test (α = 0.05). The comparison between the group of patients with active IBD and the group with IBD in remission provided good PLS-DA models (P value 0.002 for serum and 0.003 for urine). The metabolites that allowed to distinguish these groups were: N-acetylated compounds and phenylalanine (up-regulated in serum), low-density lipoproteins and very low-density lipoproteins (decreased in serum) as well as glycine (increased in urine) and acetoacetate (decreased in urine). The significant differences in metabolomic profiles were also found between the group of patients with active IBD and healthy control subjects providing the PLS-DA models with a very good separation (P value fingerprinting of serum and urine has the potential to be a useful tool in distinguishing patients with active IBD from those in remission.

  6. Saliva, Serum Levels of Interleukin-21, -33 and Prostaglandin E2 in Patients with Generalised Aggressive or Chronic Periodontitis.

    Science.gov (United States)

    Gümüş, Pınar; Nizam, Nejat; Nalbantsoy, Ayşe; Özçaka, Özgün; Buduneli, Nurcan

    This cross-sectional study aims to evaluate saliva, serum levels of interleukin-21 (IL-21), IL-33, and prostaglandin E2 (PGE2) in patients with generalised chronic periodontitis or aggressive periodontitis. Before initiation of any periodontal treatment, saliva and serum samples were collected and clinical periodontal measurements were recorded from 94 participants (25 aggressive periodontitis patients, 25 chronic periodontitis patients, 44 periodontally healthy individuals). IL-21, IL-33 and PGE2 levels in serum and saliva samples were determined by ELISA. Data were tested statistically using Kruskal-Wallis, Mann-Whitney U-, and Spearman-rho rank tests. Saliva IL-33 levels were statistically significantly higher in the chronic than the aggressive group (p periodontitis groups. Saliva IL-33 levels correlated with age in the chronic periodontitis group (p periodontitis groups (p chronic and aggressive periodontitis, but the present findings support the role of these cytokines in periodontitis. Statistically significantly higher saliva IL-33 levels in the chronic periodontitis group warrant further research.

  7. Significance of serum and urine β2-MG abnormality for diabetes

    International Nuclear Information System (INIS)

    Yu Fengling; Zhang Qiliang; Feng Zhixu; Hou Xiangzhen

    1995-01-01

    Levels of serum and urine β 2 -MG are determined in 114 patients with diabetes. It is found that levels of serum and urine β 2 -MG in diabetes are significantly higher than that of normal contrasts (P 2 -MG are increased with diabetes progress, especially urine β 2 -MG. There is no difference in levels of serum and urine β 2 -MG between non-insulin dependent diabetes mellitus (NIDDM) and insulin dependent diabetes mellitus (IDDM, P>0.05). Urine β 2 -MG levels of diabetes are relatively increased with the increase of serum β 2 -MG levels. Both are obviously positive correlation. While diabetes progressing, both are gradually increased. It can be shown that the longer diabetes process, the more renal function was damaged. Therefore, determination of β 2 -MG is very important for early diagnosing, preventing and treating diabetic nephropathy

  8. Pilot study of the pharmacokinetics of betel nut and betel quid biomarkers in saliva, urine, and hair of betel consumers.

    Science.gov (United States)

    Franke, Adrian A; Li, Xingnan; Lai, Jennifer F

    2016-10-01

    Approximately 600 million people worldwide practise the carcinogenic habit of betel nut/quid chewing. Carcinogenic N-nitroso compounds have been identified in saliva or urine of betel chewers and the betel alkaloid arecoline in hair from habitual betel quid chewers. However, the pharmacokinetic parameters of these compounds have been little explored. Assessment of betel use by biomarkers is urgently needed to evaluate the effectiveness of cessation programmes aimed at reducing betel consumption to decrease the burden of cancers in regions of high betel consumption. In the search for biomarkers of betel consumption, we measured by liquid chromatography-mass spectrometry (LC-MS) the appearance and disappearance of betel alkaloids (characteristic for betel nuts), N-nitroso compounds, and chavibetol (characteristic for Piper Betle leaves) in saliva (n=4), hair (n=2), and urine (n=1) of occasional betel nut/quid chewers. The betel alkaloids arecoline, guvacoline, guvacine, and arecaidine were detected in saliva of all four participants and peaked within the first 2 h post-chewing before returning to baseline levels after 8 h. Salivary chavibetol was detected in participants consuming Piper Betle leaves in their quid and peaked ~1 h post-chewing. Urinary arecoline, guvacoline, and arecaidine excretion paralleled saliva almost exactly while chavibetol glucuronide excretion paralleled salivary chavibetol. No betel nut related compounds were detected in the tested hair samples using various extraction methods. From these preliminary results, we conclude that betel exposure can only be followed on a short-term basis (≤8 h post-chewing) using the applied biomarkers from urine and saliva while the feasibility of using hair has yet to be validated. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  9. Relationship of serum and saliva calcium, phosphorus and alkaline phosphatase with dry mouth feeling in menopause.

    Science.gov (United States)

    Agha-Hosseini, Farzaneh; Mirzaii-Dizgah, Iraj; Moosavi, Mahdieh-Sadat

    2012-06-01

    The aim of this study was to compare serum and saliva calcium, phosphorus and alkaline phosphatase of menopausal women with/without dry mouth (DM) feeling. The composition of saliva in menopause women with/without DM feeling is different. Some of these differences are in hormones that are related to bone turnover. A case-control study was carried out on 60 selected menopausal women aged 45-79 years with or without DM feeling (30 as case, 30 as control), conducted at the Clinic of Oral Medicine, Tehran University of Medical Sciences. The phosphorus concentration was measured by photometrical measurement of the blue colour formed after the addition of ammonium molybdate and stannous chloride; calcium was measured by Arsenazo reaction; and alkaline phosphatase by the pNPP-AMP method. Statistical analysis of Student's t-test was used. The mean serum phosphorus and alkaline phosphatase, stimulated and unstimulated saliva calcium and alkaline phosphatase levels were significantly higher in the menopausal women suffering from DM. There were no significant differences between groups regarding saliva phosphorus and serum calcium concentration. Calcium, phosphorus and alkaline phosphatase appear associated with DM feeling in menopause. © 2012 The Gerodontology Society and John Wiley & Sons A/S.

  10. Detection of phencyclidine usage by radioimmunoassay of saliva

    International Nuclear Information System (INIS)

    McCarron, M.M.; Walberg, C.B.; Soares, J.R.; Gross, S.J.; Baselt, R.C.

    1984-01-01

    Paired serum and saliva samples, obtained from 100 emergency department patients suspected of phencyclidine (PCP) intoxication, were analyzed using a specific PCP radioimmunoassay (RIA). Seventy-four of the 100 saliva samples and 75 of the paired serum samples were positive for PCP. The final clinical diagnosis was PCP intoxication in 79 cases. Of these, both serum and saliva tests were positive in 70 cases, only serum was positive in two cases, and both serum and saliva samples were negative in seven cases. The concentration of PCP in the samples did not correlate with the severity of PCP intoxication. In the remaining 21 cases, with no clinical evidence of PCP intoxication, PCP assays were negative in both serum and saliva in 17 cases, three patients had positive saliva and serum tests, and one other patient had a positive PCP saliva assay. Thus, saliva would appear to be as reliable as serum as a specimen for PCP analysis

  11. Interleukin-6 and neopterin levels in the serum and saliva of patients with Lichen planus and oral Lichen planus.

    Science.gov (United States)

    Abdel-Haq, Ayman; Kusnierz-Cabala, Beata; Darczuk, Dagmara; Sobuta, Eliza; Dumnicka, Paulina; Wojas-Pelc, Anna; Chomyszyn-Gajewska, Maria

    2014-11-01

    Lichen planus together with its oral variant is a chronic, inflammatory disease of the skin and the mucosa of unclear aetiology and with an unpredictable course that still poses a major problem in terms of diagnosis and treatment. The objective of this study was to assess the concentrations of interleukin-6 (IL-6) and neopterin in saliva and serum of patients with lichen planus (including reticular and erosive form of oral lichen planus) and to compare them with the concentrations observed in healthy controls. The study material comprised serum and saliva samples from 56 patients diagnosed with lichen planus and 56 healthy volunteers. The ELISA test was used to measure concentrations of IL-6 and neopterin in the serum and saliva of the study participants. The concentrations of IL-6 in saliva and serum of patients with lichen planus were significantly higher than in controls (P = 0.0002; P oral lichen planus had significantly higher IL-6 concentrations in their saliva compared to patients with reticular form of disease (P = 0.01). The concentrations of neopterin were significantly higher in the serum but not in saliva of lichen planus patients vs. controls (P lichen planus as well as the salivary concentrations of IL-6. The differences observed in IL-6 levels in patients with erosive-atrophic forms of oral lichen planus may indicate a substantial role played by the cytokine in the disease. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. The effect of sex and time of day on testosterone concentrations in equine saliva and serum

    DEFF Research Database (Denmark)

    Andersen, Rikke Munk; Jensen, R.B.; Palme, R.

    2016-01-01

    In terms of exercise, testosterone is important for the growth and maintenance of skeletal muscle mass. Sampling saliva could be a non-invasive alternative to blood sampling for the quantification of testosterone levels in horses. The objective of this study was to compare testosterone concentrat......In terms of exercise, testosterone is important for the growth and maintenance of skeletal muscle mass. Sampling saliva could be a non-invasive alternative to blood sampling for the quantification of testosterone levels in horses. The objective of this study was to compare testosterone......:00-08:00), at midday (11:00-13:00) and in the evening (17:00-19:00). The results demonstrated a weak correlation between saliva and serum testosterone concentrations (rs=0.25, P=0.04). Stallions had higher serum testosterone concentrations than mares and geldings (Peffect of sex...

  13. Longitudinal Study of Hepatitis A Infection by Saliva Sampling: The Kinetics of HAV Markers in Saliva Revealed the Application of Saliva Tests for Hepatitis A Study

    Science.gov (United States)

    Amado Leon, Luciane Almeida; de Almeida, Adilson José; de Paula, Vanessa Salete; Tourinho, Renata Santos; Villela, Daniel Antunes Maciel; Gaspar, Ana Maria Coimbra; Lewis-Ximenez, Lia Laura; Pinto, Marcelo Alves

    2015-01-01

    Despite the increasing numbers of studies investigating hepatitis A diagnostic through saliva, the frequency and the pattern of hepatitis A virus (HAV) markers in this fluid still remains unknown. To address this issue, we carried on a longitudinal study to examine the kinetics of HAV markers in saliva, in comparison with serum samples. The present study followed-up ten patients with acute hepatitis A infection during 180 days post diagnosis (dpd). Total anti-HAV was detected in paired serum and saliva samples until the end of the follow-up, showing a peak titer at 90th. However, total anti-HAV level was higher in serum than in saliva samples. This HAV marker showed a probability of 100% to be detected in both serum and saliva during 180 dpd. The IgM anti-HAV could be detected in saliva up to 150 dpd, showing the highest frequency at 30th, when it was detected in all individuals. During the first month of HAV infection, this acute HAV marker showed a detection probability of 100% in paired samples. The detection of IgM anti-HAV in saliva was not dependent on its level in serum, HAV-RNA detection and/or viral load, since no association was found between IgM anti-HAV positivity in saliva and any of these parameter (p>0.05). Most of the patients (80%) were found to contain HAV-RNA in saliva, mainly at early acute phase (30th day). However, it was possible to demonstrate the HAV RNA presence in paired samples for more than 90 days, even after seroconversion. No significant relationship was observed between salivary HAV-RNA positivity and serum viral load, demonstrating that serum viral load is not predictive of HAV-RNA detection in saliva. Similar viral load was seen in paired samples (on average 104 copies/mL). These data demonstrate that the best diagnostic coverage can be achieved by salivary anti-HAV antibodies and HAV-RNA tests during 30–90 dpd. The long detection and high probability of specific-HAV antibodies positivity in saliva samples make the assessment of

  14. Clinical significance of determination of changes of serum IL-6, hs-CRP and saliva secretory IgA levels after treatment in patients with periodontitis

    International Nuclear Information System (INIS)

    Wang Tongwu

    2009-01-01

    Objective: To explore the clinical significance of changes of serum IL-6, hs-CRP and saliva secretory IgA levels after treatment in patients with periodontitis. Methods: Serum IL-6, saliva secretory IgA (with RIA) and serum hs-CRP (with immuno-tarbility method) levels were measured in 42 patients with periodontitis both before and after treatment as well as in 35 controls. Results: Before treatment serum IL-6, hs-CRP and saliva secretory IgA levels in the patients wree significantly higher than those in controls (P 0.05). However, the saliva secreatory IgA levels were still significantly higher than those in controls (P<0.05). Conclusion: There was disturbance of immunomodulation in patients with periodontitis as expressed by the changes of cytokines levels in the course of the diseases. (authors)

  15. Determination of some psychotropic drugs in serum and saliva samples by HPLC-DAD and HPLC MS.

    Science.gov (United States)

    Petruczynik, A; Wróblewski, K; Szultka-Młyńska, M; Buszewski, B; Karakuła-Juchnowicz, H; Gajewski, J; Morylowska-Topolska, J; Waksmundzka-Hajnos, M

    2016-08-05

    A simple, rapid and sensitive HPLC-DAD method has been developed and validated for the simultaneous determination of seven psychotropic drugs (risperidone, citalopram, clozapine,quetiapine, levomepromazine, perazine and aripiprazole) in human serum or saliva samples. The chromatographic analyses were performed on a XSELECT CSH Phenyl-Hexyl column with a mobile phase containing methanol, acetate buffer at pH 3.5 and 0.025mL(-1) diethylamine. The influence of concentration of methanol in injection samples and injection volume on peak symmetry and system efficiency was examined.The full separation of all investigated drugs, good peaks' symmetry and simultaneously high systems efficiency were obtained in applied chromatographic system. The method is suitable for the analysis of investigated drugs in human plasma or saliva for psychiatric patients for control of pharmacotherapy, particularly in combination therapy. HPLC-MS was applied for verification of the presence of drugs and their metabolites in serum and saliva samples from patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Cadmium monitoring in saliva and urine as indicator of smoking addiction

    Energy Technology Data Exchange (ETDEWEB)

    Talio, Maria Carolina [Instituto de Quimica de San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, 5700 San Luis (Argentina); Luconi, Marta O. [Area de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad Nacional de San Luis (Argentina); Masi, Adriana N. [Area de Bromatologia- Ensayo y Valoracion de Medicamentos, Facultad de Quimica, Bioquimica y Farmacia, Universidad Nacional de San Luis (Argentina); Instituto de Quimica de San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, 5700 San Luis (Argentina); Fernandez, Liliana P., E-mail: lfernand@unsl.edu.ar [Area de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad Nacional de San Luis (Argentina); Instituto de Quimica de San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, 5700 San Luis (Argentina)

    2010-07-15

    Cadmium is one of the many substances that may be acquired through active and passive smoking of tobacco. Saliva and urine are proposed for cadmium monitoring of non-smokers, second hand smokers, smokers and tobacco chewing appertaining to San Luis citizens without occupational exposition. Biological samples were collected by the same subjects, under strict proceeding instructions of sampling. Physical characteristics of samples were observed and checked with commercial test. Samples were analyzed using an adapted molecular fluorescence methodology with a previous extraction step. Stability of biological samples was daily studied for a period of one month. The method was successfully validated for accuracy, precision, linearity, specificity, and sensitivity. The simplicity and low coefficient of variance confirm the suitability of the method for urinary and salivary cadmium analyses. On the other side, the obtained results are in concordance with previous national epidemiological dates.

  17. Cadmium monitoring in saliva and urine as indicator of smoking addiction

    International Nuclear Information System (INIS)

    Talio, Maria Carolina; Luconi, Marta O.; Masi, Adriana N.; Fernandez, Liliana P.

    2010-01-01

    Cadmium is one of the many substances that may be acquired through active and passive smoking of tobacco. Saliva and urine are proposed for cadmium monitoring of non-smokers, second hand smokers, smokers and tobacco chewing appertaining to San Luis citizens without occupational exposition. Biological samples were collected by the same subjects, under strict proceeding instructions of sampling. Physical characteristics of samples were observed and checked with commercial test. Samples were analyzed using an adapted molecular fluorescence methodology with a previous extraction step. Stability of biological samples was daily studied for a period of one month. The method was successfully validated for accuracy, precision, linearity, specificity, and sensitivity. The simplicity and low coefficient of variance confirm the suitability of the method for urinary and salivary cadmium analyses. On the other side, the obtained results are in concordance with previous national epidemiological dates.

  18. Assessment of extracellular dehydration using saliva osmolality.

    Science.gov (United States)

    Ely, Brett R; Cheuvront, Samuel N; Kenefick, Robert W; Spitz, Marissa G; Heavens, Kristen R; Walsh, Neil P; Sawka, Michael N

    2014-01-01

    When substantial solute losses accompany body water an isotonic hypovolemia (extracellular dehydration) results. The potential for using blood or urine to assess extracellular dehydration is generally poor, but saliva is not a simple ultra-filtrate of plasma and the autonomic regulation of salivary gland function suggests the possibility that saliva osmolality (Sosm) may afford detection of extracellular dehydration via the influence of volume-mediated factors. This study aimed to evaluate the assessment of extracellular dehydration using Sosm. In addition, two common saliva collection methods and their effects on Sosm were compared. Blood, urine, and saliva samples were collected in 24 healthy volunteers during paired euhydration and dehydration trials. Furosemide administration and 12 h fluid restriction were used to produce extracellular dehydration. Expectoration and salivette collection methods were compared in a separate group of eight euhydrated volunteers. All comparisons were made using paired t-tests. The diagnostic potential of body fluids was additionally evaluated. Dehydration (3.1 ± 0.5% loss of body mass) decreased PV (-0.49 ± 0.12 L; -15.12 ± 3.94% change), but Sosm changes were marginal ( 0.05). Extracelluar dehydration was not detectable using plasma, urine, or saliva measures. Salivette and expectoration sampling methods produced similar, consistent results for Sosm, suggesting no methodological influence on Sosm.

  19. Saliva Preservative for Diagnostic Purposes

    Science.gov (United States)

    Pierson, Duane L.; Mehta, Satish K.

    2012-01-01

    Saliva is an important body fluid for diagnostic purposes. Glycoproteins, glucose, steroids, DNA, and other molecules of diagnostic value are found in saliva. It is easier to collect as compared to blood or urine. Unfortunately, saliva also contains large numbers of bacteria that can release enzymes, which can degrade proteins and nucleic acids. These degradative enzymes destroy or reduce saliva s diagnostic value. This innovation describes the formulation of a chemical preservative that prevents microbial growth and inactivates the degradative enzymes. This extends the time that saliva can be stored or transported without losing its diagnostic value. Multiple samples of saliva can be collected if needed without causing discomfort to the subject and it does not require any special facilities to handle after it is collected.

  20. Serum and Urine Copper – Contamination and Stability

    OpenAIRE

    Dimitrova Ivanova I.; Atanasova B.; Dragneva S.; Vladimirova L.; Krastev Z.; Kostadinova A.; Ivanova A.; Tzatchev K.

    2015-01-01

    Pre-analytical factors of variation need to be carefully considered and investigated in efforts to harmonize all aspects of the total testing process. This study aimed to evaluate contamination and stability in copper (Cu) analysis of serum and urine by flame atomic absorption spectroscopy (FAAS) and to compare the stability of urine Cu in controls and in D-penicillamine (D-PA) administration. Cu was measured by AAnalyst 400, Perkin Elmer, USA. Blood was collected in BD Vacutainer®SSTTM II Ad...

  1. Zinc and selenium in serum and urine of Duchenne muscular dystrophy patients

    International Nuclear Information System (INIS)

    Reyes, J.; Holmgren, J.

    1993-01-01

    Zn and Se levels were measured by the method of neutron activation analysis in serum and urine of Duchenne Muscular Dystrophy (DMD) patients, comparing them with a well paired control group in order to help defining the phenotype of this pathology and the role these trace elements could have in the physiopathology of this disease. The levels of Zn and Se in serum and urine in DMD patients are higher than in controls. A tendency to higher levels of Zn in serum LDH and CK is observed in patients of lower age. (author)

  2. Low Cotinine Glucuronidation Results in Higher Serum and Saliva Cotinine in African American Compared to White Smokers.

    Science.gov (United States)

    Murphy, Sharon E; Sipe, Christopher J; Choi, Kwangsoo; Raddatz, Leah M; Koopmeiners, Joseph S; Donny, Eric C; Hatsukami, Dorothy K

    2017-07-01

    Background: Tobacco exposure is often quantified by serum or saliva concentrations of the primary nicotine metabolite, cotinine. However, average cotinine concentrations are higher in African Americans (AA) compared with Whites with similar smoking levels. Cotinine is metabolized by UGT2B10 and CYP2A6, and low UGT2B10 activity is common in AA, due to the prevalence of a UGT2B10 splice variant. Methods: UGT2B10 activity was phenotyped in 1,446 smokers (34% AA) by measuring the percentage of cotinine excreted as a glucuronide. Urinary total nicotine equivalents (TNE), the sum of nicotine and 6 metabolites, were determined to quantify smoking dose, and cotinine and 3'-hydroxycotinine were quantified in saliva (study 1) or serum (study 2). Results: Ninety-seven smokers (78% AA) were null for UGT2B10 activity, and the saliva and serum cotinine levels, after adjustment for TNE and cigarettes per day (CPD), were 68% and 48% higher in these smokers compared with nonnull smokers ( P smokers, but with additional adjustment for UGT2B10 activity, there were no significant differences in saliva and serum cotinine concentrations between these two groups. Conclusions: UGT2B10 activity significantly influences plasma cotinine levels, and higher cotinine concentrations in AA versus White smokers (after adjustment for smoking dose) result from lower levels of UGT2B10-catalyzed cotinine glucuronidation by AA. Impact: UGT2B10 activity or genotype should be considered when using cotinine as a tobacco exposure biomarker, particularly in populations such as AA with high frequencies of UGT2B10 nonfunctional variants. Cancer Epidemiol Biomarkers Prev; 26(7); 1093-9. ©2017 AACR . ©2017 American Association for Cancer Research.

  3. Differences in urine cadmium associations with kidney outcomes based on serum creatinine and cystatin C

    International Nuclear Information System (INIS)

    Weaver, Virginia M.; Kim, Nam-Soo; Lee, Byung-Kook; Parsons, Patrick J.; Spector, June; Fadrowski, Jeffrey; Jaar, Bernard G.; Steuerwald, Amy J.; Todd, Andrew C.

    2011-01-01

    Cadmium is a well-known nephrotoxicant; chronic exposure increases risk for chronic kidney disease. Recently, however, associations between urine cadmium and higher creatinine-based estimated glomerular filtration rate (eGFR) have been reported. Analyses utilizing alternate biomarkers of kidney function allow evaluation of potential mechanisms for these observations. We compared associations of urine cadmium with kidney function measures based on serum cystatin C to those with serum creatinine in 712 lead workers. Mean (standard deviation) molybdenum-corrected urine cadmium, Modification of Diet in Renal Disease (MDRD) eGFR and multi-variable cystatin C eGFR were 1.02 (0.65) μg/g creatinine, and 97.4 (19.2) and 112.0 (17.7) mL/min/1.73 m 2 , respectively. The eGFR measures were moderately correlated (r s =0.5; p 2 ; 95% confidence interval=1.6, 6.6). Urine creatinine was associated with serum creatinine-based but not cystatin-C-based eGFRs. These results support a biomarker-specific, rather than a kidney function, effect underlying the associations observed between higher urine cadmium and creatinine-based kidney function measures. Given the routine use of serum and urine creatinine in kidney and biomarker research, additional research to elucidate the mechanism(s) for these associations is essential.

  4. Magnetic resonance imaging and biomarkers of serum and urine wile diagnostics of kidney cancer

    Directory of Open Access Journals (Sweden)

    Nickolsky Yu.Ye.

    2016-03-01

    Full Text Available Purpose: improvement of differential diagnostics of benign and malignant renal tumors basing on complex estimation of the results of MRTand the level of such biomarkers as vascular endothelial growth factor, monocyte chemotactic protein-1 and matrix metalloproteinase-9 in blood serum and urine. Material and Methods. A total of 106 patients including the main group of 60 patients with renal cancer (RC, the group of comparison of 16 patients with benign renal tumors and the control group of 30 practically healthy persons were examined. ELISA was employed for detection of the biomarkers in blood serum and urine. The tumors were diagnosed by MRT Results. The increase of the level of the biomarkers in blood serum and urine was registered independently of the character of neoplastic process; more significant increase was observed in patients with RC, especially at the early stages of the disease. Some peculiarities of changing of the level of the biomarkers depending on the dimensions of malignant tumors were found. Conclusion. At the early stages of RC complex detection of the abovementioned biomarkers in blood serum and urine can serve an additional clinical diagnostic and prognostic criterion.

  5. Trends in the levels of urine and serum creatinine: data from NHANES 2001-2014.

    Science.gov (United States)

    Jain, Ram B

    2017-04-01

    Data from the National Health and Nutrition Examination Survey were used to study trends for urine and serum creatinine over 2001-2014 for those aged ≥20 years. In the absence of chronic kidney disease, levels of urine creatinine decreased for the total population, for those aged 20-29, 50-59, and ≥70 years, for males, and for Mexican Americans and other race/ethnicities. Levels of serum cotinine also exhibited a decreasing trend over 2001-2014 for the total population, for those aged 20-29 and 40-49 years, for females, and for non-Hispanic whites and Mexican Americans. In general, levels of serum creatinine and urine creatinine were positively correlated for chronic kidney disease stages 1-3 and negatively correlated for chronic kidney disease stages 4 and 5.

  6. Tumor, serum and urine carcinoembryonic antigen (CEA) in upper urinary tract urothelial cancer

    International Nuclear Information System (INIS)

    Stefanovic, V.; Ignjatovic, M.

    1987-01-01

    The aim of this investigation was to study the possible diagnostic value of a CEA test in cancer of the renal pelvis and ureter. Thirty-eight patients with upper urinary tract cancer, 15 patients with transitional cell carcinoma of the bladder, 6 kidney carcinoma patients and 25 healthy adults were studied. CEA was determined in tumor tissue, serum and urine, by using a monoclonal radioimmunoassay. Increased serum CEA level was found in 7 out of 27 patients (26%) with active cancer of the renal pelvis and ureter. None of 11 patients with inactive cancer had an increased serum CEA level. No significant correlation was found between the serum CEA level and the histological grading. The tumor CEA content varied markedly, from values obtainted in normal urothelium up to 840 ng/g wet weight. CEA content of tumor tissue did not correlate with the serum level. Our data suggest that serum and urine CEA have not diagnostic accuracy for clinical diagnosis of upper tract urothelial cancer. (orig.) [de

  7. Pilot study of the pharmacokinetics of betel nut and betel quid biomarkers in saliva, urine, and hair of betel consumers

    OpenAIRE

    Franke, Adrian A.; Li, Xingnan; Lai, Jennifer F.

    2015-01-01

    Approximately 600 million people worldwide practise the carcinogenic habit of betel nut/quid chewing. Carcinogenic N-nitroso compounds have been identified in saliva or urine of betel chewers and the betel alkaloid arecoline in hair from habitual betel quid chewers. However, the pharmacokinetic parameters of these compounds have been little explored. Assessment of betel use by biomarkers is urgently needed to evaluate the effectiveness of cessation programmes aimed at reducing betel consumpti...

  8. Comparison of proteomic biomarker panels in urine and serum for ovarian cancer diagnosis

    DEFF Research Database (Denmark)

    Petri, Anette Lykke; Simonsen, Anja Hviid; Høgdall, Estrid

    2010-01-01

    The purposes of this study were to confirm previously found candidate epithelial ovarian cancer biomarkers in urine and to compare a paired serum biomarker panel and a urine biomarker panel from the same study cohort with regard to the receiver operating characteristic curve (ROC) area under the ...

  9. The human volatilome: volatile organic compounds (VOCs) in exhaled breath, skin emanations, urine, feces and saliva.

    Science.gov (United States)

    Amann, Anton; Costello, Ben de Lacy; Miekisch, Wolfram; Schubert, Jochen; Buszewski, Bogusław; Pleil, Joachim; Ratcliffe, Norman; Risby, Terence

    2014-09-01

    Breath analysis is a young field of research with its roots in antiquity. Antoine Lavoisier discovered carbon dioxide in exhaled breath during the period 1777-1783, Wilhelm (Vilém) Petters discovered acetone in breath in 1857 and Johannes Müller reported the first quantitative measurements of acetone in 1898. A recent review reported 1765 volatile compounds appearing in exhaled breath, skin emanations, urine, saliva, human breast milk, blood and feces. For a large number of compounds, real-time analysis of exhaled breath or skin emanations has been performed, e.g., during exertion of effort on a stationary bicycle or during sleep. Volatile compounds in exhaled breath, which record historical exposure, are called the 'exposome'. Changes in biogenic volatile organic compound concentrations can be used to mirror metabolic or (patho)physiological processes in the whole body or blood concentrations of drugs (e.g. propofol) in clinical settings-even during artificial ventilation or during surgery. Also compounds released by bacterial strains like Pseudomonas aeruginosa or Streptococcus pneumonia could be very interesting. Methyl methacrylate (CAS 80-62-6), for example, was observed in the headspace of Streptococcus pneumonia in concentrations up to 1420 ppb. Fecal volatiles have been implicated in differentiating certain infectious bowel diseases such as Clostridium difficile, Campylobacter, Salmonella and Cholera. They have also been used to differentiate other non-infectious conditions such as irritable bowel syndrome and inflammatory bowel disease. In addition, alterations in urine volatiles have been used to detect urinary tract infections, bladder, prostate and other cancers. Peroxidation of lipids and other biomolecules by reactive oxygen species produce volatile compounds like ethane and 1-pentane. Noninvasive detection and therapeutic monitoring of oxidative stress would be highly desirable in autoimmunological, neurological, inflammatory diseases and cancer

  10. Variation of serum and urine cotinine in passive and active smokers and applicability in preconceptional smoking cessation counseling

    International Nuclear Information System (INIS)

    Weerd, Sabina de; Thomas, Chris M.G.; Kuster, Josien E.T.G.; Cikot, Rolf J.L.M.; Steegers, Eric A.P.

    2002-01-01

    This study assessed the applicability of serum and urine cotinine as a biochemical marker of self-reported smoking habits for use in a preconception smoking cessation program. The variation of serum and urine cotinine over the course of the day was investigated in a sample of 21 smokers and 8 passive smokers who reported their smoking habits and exposure to smoke daily in a questionnaire for 10 consecutive days. Blood and urine samples were collected on two sampling days, 1 week apart. Both serum and urine cotinine assay could distinguish between passive and active smokers, but not between higher categories of smokers (1019 and ≥20 cigarettes per ay) due to significant intersubject overlap. In serum, no significant differences were found between morning and afternoon cotinine concentrations in either day, in contrast to urine cotinine (with lower excretions observed n the morning). An overall coefficient of variation of 22- was observed for both specimens in smokers. Because serum cotinine is subject to lower variability over the course of the day, it is more practical for use in a clinical setting where appointments are scheduled throughout the day in order o confirm smoking status

  11. Determination of inorganic nitrate in serum and urine by a kinetic cadmium-reduction method.

    Science.gov (United States)

    Cortas, N K; Wakid, N W

    1990-08-01

    Nitrate in serum and urine was assayed by a modification of the cadmium-reduction method; the nitrite produced was determined by diazotization of sulfanilamide and coupling to naphthylethylene diamine. After samples were deproteinized with Somogyi reagent, the nitrate was reduced by Cu-coated Cd in glycine buffer at pH 9.7 (2.5 to 3 g of Cd granules for a 4-mL reaction mixture). The reduction followed pseudo-first-order reaction kinetics, a convenient time interval for assay being 75 to 90 min. Maximum reduction (85%) occurred at about 2 h. Detection limits in urine or serum were 2 to 250 mumol/L. This method does not require the reaction to go to completion, does not require expensive reagents or equipment, and can assay several samples simultaneously. Repeated assays of two serum pools gave CVs of 9.0% and 4.7% for nitrate concentrations of 31.4 and 80.2 mumol/L, respectively (n = 20 each). The mean concentration of nitrate was 1704.0 +/- 1294 (SD) mumol/L (n = 21) in untimed normal urine, 81.8 +/- 50.1 mumol/L in serum of 38 renal dialysis patients, and 51.2 +/- 26.4 mumol/L in serum of 38 controls.

  12. Estimation of Antioxidant Levels in Saliva and Serum of Chronic Periodontitis Patients with and without Ischemic Heart Disease

    Directory of Open Access Journals (Sweden)

    Anahita Punj

    2017-01-01

    Full Text Available Objective. To investigate whether there is a relationship between periodontitis and ischemic heart disease by estimation of total antioxidant status in saliva and serum. Materials and Methods. A total of 80 samples were collected and divided equally into 4 groups of healthy controls, chronic periodontitis patients, ischemic heart disease patients with periodontitis, and ischemic heart disease patients without periodontitis. Saliva and venous blood samples were collected and analyzed for levels of total antioxidant capacity, superoxide dismutase, glutathione peroxidase, and catalase. Results. There were significant (p<0.05 differences in the mean serum levels of total antioxidant capacity (p<0.001, superoxide dismutase (p<0.001, glutathione peroxidase (p<0.006, and catalase (p<0.001 within the 4 groups, whereas the mean salivary levels were significant only for glutathione peroxidase (p=0.001. Both of these serum and salivary antioxidant levels were lower in disease groups of IHD + CP, IHD + H, and CP as compared to healthy controls, with different patterns. Conclusion. Antioxidant capacity is significantly hampered in chronic periodontitis and ischemic heart disease patients with or without periodontitis as compared to healthy controls. The salivary and serum antioxidants may not follow the same increase or decrease as a result of increased oxidant stress due to disease.

  13. Evaluating engrailed-2 and cytokines in urine with serum PSA as ...

    African Journals Online (AJOL)

    Evaluating engrailed-2 and cytokines in urine with serum PSA as potential biomarkers in patients with prostatism at Moi Teaching and Referral Hospital, Eldoret, Kenya. B Donald-Buri, K Patel, P Musau, E.N. Fish ...

  14. Quantification of theobromine and caffeine in saliva, plasma and urine via liquid chromatography-tandem mass spectrometry: a single analytical protocol applicable to cocoa intervention studies.

    Science.gov (United States)

    Ptolemy, Adam S; Tzioumis, Emma; Thomke, Arjun; Rifai, Sami; Kellogg, Mark

    2010-02-01

    Targeted analyses of clinically relevant metabolites in human biofluids often require extensive sample preparation (e.g., desalting, protein removal and/or preconcentration) prior to quantitation. In this report, a single ultra-centrifugation based sample pretreatment combined with a designed liquid chromatography-tandem mass spectrometry (LC-MS/MS) protocol provides selective quantification of 3,7-dimethylxanthine (theobromine) and 1,3,7-trimethylxanthine (caffeine) in human saliva, plasma and urine samples. The optimized chromatography permitted elution of both analytes within 1.3 min of the applied gradient. Positive-mode electrospray ionization and a triple quadruple MS/MS instrument operated in multiple reaction mode were used for detection. (13)C(3) isotopically labeled caffeine was included as an internal standard to improve accuracy and precision. Implementing a 20-fold dilution of the isolated low MW biofluid fraction prior to injection effectively minimized the deleterious contributions of all three matrices to quantitation. The assay was linear over a 160-fold concentration range from 2.5 to 400 micromol L(-1) for both theobromine (average R(2) 0.9968) and caffeine (average R(2) 0.9997) respectively. Analyte peak area variations for 2.5 micromol L(-1) caffeine and theobromine in saliva, plasma and urine ranged from 5 and 10% (intra-day, N=10) to 9 and 13% (inter-day, N=25) respectively. The intra- and inter-day precision of theobromine and caffeine elution times were 3 and theobromine ranged from 114 to 118% and 99 to 105% at concentration levels of 10 and 300 micromol L(-1). This validated protocol also permitted the relative saliva, plasma and urine distribution of both theobromine and caffeine to be quantified following a cocoa intervention. 2009 Elsevier B.V. All rights reserved.

  15. Quantification of anti-Leishmania antibodies in saliva of dogs.

    Science.gov (United States)

    Cantos-Barreda, Ana; Escribano, Damián; Bernal, Luis J; Cerón, José J; Martínez-Subiela, Silvia

    2017-08-15

    Detection of serum anti-Leishmania antibodies by quantitative or qualitative techniques has been the most used method to diagnose Canine Leishmaniosis (CanL). Nevertheless, saliva may represent an alternative to blood because it is easy to collect, painless and non-invasive in comparison with serum. In this study, two time-resolved immunofluorometric assays (TR-IFMAs) for quantification of anti-Leishmania IgG2 and IgA antibodies in saliva were developed and validated and their ability to distinguish Leishmania-seronegative from seropositive dogs was evaluated. The analytical study was performed by evaluation of assay precision, sensitivity and accuracy. In addition, serum from 48 dogs (21 Leishmania-seropositive and 27 Leishmania-seronegative) were analyzed by TR-IFMAs. The assays were precise, with an intra- and inter-assay coefficients of variation lower than 11%, and showed high level of accuracy, as determined by linearity under dilution (R 2 =0.99) and recovery tests (>88.60%). Anti-Leishmania IgG2 antibodies in saliva were significantly higher in the seropositive group compared with the seronegative (pLeishmania IgA antibodies between both groups were observed. Furthermore, TR-IFMA for quantification of anti-Leishmania IgG2 antibodies in saliva showed higher differences between seropositive and seronegative dogs than the commercial assay used in serum. In conclusion, TR-IFMAs developed may be used to quantify anti-Leishmania IgG2 and IgA antibodies in canine saliva with an adequate precision, analytical sensitivity and accuracy. Quantification of anti-Leishmania IgG2 antibodies in saliva could be potentially used to evaluate the humoral response in CanL. However, IgA in saliva seemed not to have diagnostic value for this disease. For future studies, it would be desirable to evaluate the ability of the IgG2 assay to detect dogs with subclinical disease or with low antibody titers in serum and also to study the antibodies behaviour in saliva during the

  16. The influence of storage time and temperature on the measurement of serum, plasma and urine osmolality.

    Science.gov (United States)

    Bezuidenhout, Karla; Rensburg, Megan A; Hudson, Careen L; Essack, Younus; Davids, M Razeen

    2016-07-01

    Many clinical laboratories require that specimens for serum and urine osmolality determination be processed within 3 h of sampling or need to arrive at the laboratory on ice. This protocol is based on the World Health Organization report on sample storage and stability, but the recommendation lacks good supporting data. We studied the effect of storage temperature and time on osmolality measurements. Blood and urine samples were obtained from 16 patients and 25 healthy volunteers. Baseline serum, plasma and urine osmolality measurements were performed within 30 min. Measurements were then made at 3, 6, 12, 24 and 36 h on samples stored at 4-8℃ and room temperature. We compared baseline values with subsequent measurements and used difference plots to illustrate changes in osmolality. At 4-8℃, serum and plasma osmolality were stable for up to 36 h. At room temperature, serum and plasma osmolality were very stable for up to 12 h. At 24 and 36 h, changes from baseline osmolality were statistically significant and exceeded the total allowable error of 1.5% but not the reference change value of 4.1%. Urine osmolality was extremely stable at room temperature with a mean change of less than 1 mosmol/kg at 36 h. Serum and plasma samples can be stored at room temperature for up to 36 h before measuring osmolality. Cooling samples to 4-8℃ may be useful when delays in measurement beyond 12 h are anticipated. Urine osmolality is extremely stable for up to 36 h at room temperature. © The Author(s) 2015.

  17. Urine and serum microRNA-1 as novel biomarkers for myocardial injury in open-heart surgeries with cardiopulmonary bypass.

    Science.gov (United States)

    Zhou, Xian; Mao, Anqiong; Wang, Xiaobin; Duan, Xiaoxia; Yao, Yi; Zhang, Chunxiang

    2013-01-01

    MicroRNA-1 (miR-1) is a cardio-specific/enriched microRNA. Our recent studies have revealed that serum and urine miR-1 could be a novel sensitive biomarker for acute myocardial infarction. Open-heart surgeries with cardiopulmonary bypass (CPB) are often accompanied with surgery injury and CPB-associated injury on the hearts. However, the association of miR-1 and these intra-operative and post-operative cardiac injures is unknown. The objective of this study was to test the hypothesis that urine and serum miR-1 might be a novel biomarker for myocardial injuries in open-heart surgeries with CPB. Serum and urine miR-1 levels in 20 patients with elective mitral valve surgery were measured at pre-surgery, pre-CPB, 60 min post-CBP, and 24h post-CBP. Serum cardiac troponin-I (cTnI) was used as a positive control biomarker for cardiac injury. Compared with these in pre-operative and pre-CPB groups, the levels of miR-1 in serum and urine from patients after open-heart surgeries and CPB were significant increased at all observed time points. A similar pattern of serum cTnI levels and their strong positive correlation with miR-1 levels were identified in these patients. The results suggest that serum and urine miR-1 may be a novel sensitive biomarker for myocardial injury in open-heart surgeries with CPB.

  18. Effect of subchronic zinc toxicity on rat salivary glands and serum composition.

    Science.gov (United States)

    Mizari, Nazer; Hirbod-Mobarakeh, Armin; Shahinpour, Shervin; Ghalichi-Tabriz, Mostafa; Beigy, Maani; Yamini, Ali; Dehpour, Ahmad Reza

    2012-11-01

    Zinc plays an important role in a wide variety of metabolic processes in animal systems. The role of zinc in preservative treatment, fungicidal action and medicine, and addition of supplementary zinc have increased the probability of zinc toxicity, specially the chronic type. It is known that the composition and quantity of saliva influence the oral health. Regarding people's exposure to zinc in routine life and the importance of saliva, our purpose was to investigate the effects of oral zinc intoxication on secretory function in rat salivary glands and also on serum composition. In this study, there were five groups of female rats. Four groups received zinc acetate dehydrate through their drinking water. After 3 months of experiment, the chemical characteristics and flow rate of saliva and weight of salivary glands were determined. The effects of zinc on hematological and chemical factors of plasma were assessed too. Flow rate of submandibular glands was significantly lower in experimental groups and there were significant changes in Na(+), Ca(2+) and K(+) concentration both in saliva and in plasma. The serum glutamate oxaloacetate transaminase, serum glutamate pyruvate transaminase, glucose levels in the plasma and urine creatinine levels were also altered in experimental groups in comparison with the control group. Our results show that zinc toxicity will affect the quantity and quality of saliva probably through changes in the various neurologic pathways to the salivary glands or effects on acinar cells of the salivary glands. Furthermore, our results showed that zinc toxicity will affect the liver and renal function.

  19. Radioimmunoassay of class-specific antibodies to Streptococcus mutans in monkey serum and saliva

    International Nuclear Information System (INIS)

    Walker, J.; Colman, G.; Huges, M.

    1979-01-01

    A radioimmunoassay (RIA) has been developed to measure class-specific antibodies to Streptococcus mutans in the serum and saliva of monkeys (Macaca fascicularis). Antihuman immunoglobulin antibodies purified by affinity chromatography on immobilised monkey immoglobulins and labelled with 125 I were employed. Formalised cells of S. mutans and an extract of culture supernatant adsorbed to polystyrene wells were used as solid-phase antigens. The coefficients of variation of IgG, IgA, and IgM assays were less than or equal to 10% for both antigen systems. It is shown that this RIA is a sensitive, reproducible and quantitative method. (Auth.)

  20. Per- and polyfluoroalkyl substances in human serum and urine samples from a residentially exposed community.

    Science.gov (United States)

    Worley, Rachel Rogers; Moore, Susan McAfee; Tierney, Bruce C; Ye, Xiaoyun; Calafat, Antonia M; Campbell, Sean; Woudneh, Million B; Fisher, Jeffrey

    2017-09-01

    Per- and polyfluoroalkyl substances (PFAS) are considered chemicals of emerging concern, in part due to their environmental and biological persistence and the potential for widespread human exposure. In 2007, a PFAS manufacturer near Decatur, Alabama notified the United States Environmental Protection Agency (EPA) it had discharged PFAS into a wastewater treatment plant, resulting in environmental contamination and potential exposures to the local community. To characterize PFAS exposure over time, the Agency for Toxic Substances and Disease Registry (ATSDR) collected blood and urine samples from local residents. Eight PFAS were measured in serum in 2010 (n=153). Eleven PFAS were measured in serum, and five PFAS were measured in urine (n=45) from some of the same residents in 2016. Serum concentrations were compared to nationally representative data and change in serum concentration over time was evaluated. Biological half-lives were estimated for perfluorooctanoic acid (PFOA), perfluorooctane sulfonic acid (PFOS), and perfluorohexane sulfonic acid (PFHxS) using a one-compartment pharmacokinetic model. In 2010 and 2016, geometric mean PFOA and PFOS serum concentrations were elevated in participants compared to the general U.S. In 2016, the geometric mean PFHxS serum concentration was elevated compared to the general U.S. Geometric mean serum concentrations of PFOA, PFOS, and perfluorononanoic acid (PFNA) were significantly (p≤0.0001) lower (49%, 53%, and 58%, respectively) in 2016 compared to 2010. Half-lives for PFOA, PFOS, and PFHxS were estimated to be 3.9, 3.3, and 15.5years, respectively. Concentrations of PFOA in serum and urine were highly correlated (r=0.75) in males. Serum concentrations of some PFAS are decreasing in this residentially exposed community, but remain elevated compared to the U.S. general population. Published by Elsevier Ltd.

  1. Clinical significance of determination of serum and urine β2-microglobulin (β2-m) in patients with Graves' disease

    International Nuclear Information System (INIS)

    Wang Luhua; Mai Mang; Ouyang Xiaoqing; Wang Shuhua; Lin Cen; Fang Linli

    2005-01-01

    Objective: To explore the relationship between the serum, urine contents of β 2 -m and serum thyroid hormones levels in patients with Graves' disease. Methods: Serum, urine β 2 -m contents (with RIA), serum FT 3 , FT 4 levels (with CLIA), TGA, TMA positive rates (with RIA) were determined in 82 patients with Graves' disease both before and after treatment as well as in 40 controls. Results: The serum and urine β 2 -m contents as well as the serum FT 3 , FT 4 levels in the 82 hyperthyroid patients before treatment were significantly higher than those in the controls (P 2 -m, FT 3 , FT 4 levels dropped to approaching normal (vs controls, P>0.05). In the 13 treatment failures, the levels remained significantly higher than those in controls (P 2 -m contents after treatment paralleled those of FT 3 , FT 4 levels. β 2 -m could be used as a diagnostic indicator for hyperthyroidism. (authors)

  2. Direct determination of lead in human urine and serum samples by electrothermal atomic absorption spectrometry and permanent modifiers

    International Nuclear Information System (INIS)

    Andrada, Daniel; Pinto, Frederico G.; Magalhaes, Cristina Goncalves; Nunes, Berta R.; Silva, Jose Bento Borba da; Franco, Milton B.

    2006-01-01

    The object of the present study was the development of alternative methods for the direct determination of lead in undigested samples of human urine and serum by electrothermal atomic absorption spectrometry (ETAAS). Thus, some substances have been investigated to act as chemical modifiers. Volumes of 20 μL of diluted samples, 1 + 1, v/v for urine and 1 + 4, v/v for serum, with HNO 3 1% v/v and 0.02% v/v of cetyl trimethyl ammonium chloride (CTAC) were prepared directly in the autosampler cups and placed into the graphite furnace. For modifiers in solutions 10 μL were used. Pyrolysis and atomization temperature curves were used in all optimizations in the matrixes diluted as exposed. For urine with permanent iridium (500 μg), the best pyrolysis and atomization temperatures were 900 and 1600 deg C, respectively, with a characteristic mass of 12 pg (recommended of 10 pg), with symmetrical absorption pulses and corrected background. Spiked urine samples presented recoveries between 86 and 112% for Ir permanent. The analysis results of certified urine samples are in agreement with certified values (95% of confidence) for two levels of the metal. For serum, good results were obtained with the mixture of Zr+Rh or Ir+Rh as permanent modifiers, with characteristic masses of 9.8 and 8.1 pg, respectively. Recoveries from spiked serum samples varied between 98.6 and 100.1% (Ir+Rh) and between 93.9 and 105.2% (Zr+Rh). In both recovery studies, the relative standard deviation (n=3) was lower than 7%. Calibration for both samples were made with aqueous calibration curves and presented r 2 higher than 0.99. The limits of detection were 0.7 μg L -1 for serum samples, with Zr+Rh permanent, and 1.0 μg L -1 for urine with iridium permanent. (author)

  3. Direct determination of lead in human urine and serum samples by electrothermal atomic absorption spectrometry and permanent modifiers

    Directory of Open Access Journals (Sweden)

    Andrada Daniel

    2006-01-01

    Full Text Available The object of the present study was the development of alternative methods for the direct determination of lead in undigested samples of human urine and serum by electrothermal atomic absorption spectrometry (ET AAS. Thus, some substances have been investigated to act as chemical modifiers. Volumes of 20 µL of diluted samples, 1 + 1, v/v for urine and 1 + 4, v/v for serum, with HNO3 1% v/v and 0.02% v/v of cetil trimethyl ammonium chloride (CTAC were prepared directly in the autosampler cups and placed into the graphite furnace. For modifiers in solutions 10 µL were used. Pyrolysis and atomization temperature curves were used in all optimizations in the matrixes diluted as exposed. For urine with permanent iridium (500 µg, the best pyrolysis and atomization temperatures were 900 and 1600 ºC, respectively, with a characteristic mass of 12 pg (recommended of 10 pg, with symmetrical absorption pulses and corrected background. Spiked urine samples presented recoveries between 86 and 112% for Ir permanent. The analysis results of certified urine samples are in agreement with certified values (95% of confidence for two levels of the metal. For serum, good results were obtained with the mixture of Zr+Rh or Ir+Rh as permanent modifiers, with characteristic masses of 9.8 and 8.1 pg, respectively. Recoveries from spiked serum samples varied between 98.6 and 100.1% (Ir+Rh and between 93.9 and 105.2% (Zr+Rh. In both recovery studies, the relative standard deviation (n=3 was lower than 7%. Calibration for both samples were made with aqueous calibration curves and presented r² higher than 0.99. The limits of detection were 0.7 µg L-1 for serum samples, with Zr+Rh permanent, and 1.0 µg L-1 for urine with iridium permanent.

  4. Influence of storage conditions on aluminum concentrations in serum, dialysis fluid, urine, and tap water.

    Science.gov (United States)

    Wilhelm, M; Ohnesorge, F K

    1990-01-01

    The influence of storage temperature, vessel type, and treatment on alterations of aluminum (Al) concentrations in serum, urine, and dialysis fluid samples was studied at three different concentrations for each sample over an 18-month period. Furthermore, the influence of acidification on Al levels in tap water, urine, and dialysis fluid samples was studied over a four-month period. Al was measured by atomic absorption spectrometry. Sample storage in glass vessels was unsuitable, whereas only minor alterations of Al levels were observed with storage in polypropylene tubes, polystyrene tubes, and Monovettes. By using appropriate plastic containers, acid washing of the vessels showed no improvement. Frozen storage was superior compared with 4 degrees C, whereas storage at -80 degrees C offered no advantage compared with storage at -20 degrees C. Acidification of tap water samples was necessary to stabilize Al levels during storage. No striking effect of acidification on Al levels in urine and dialysis fluid samples was found. It is concluded that longterm storage of serum, urine, tap water, and dialysis fluid samples is possible if appropriate conditions are used.

  5. GFR, serum creatinine and 24-hour urine protein in evaluating renal function of patients with diabetes mellitus

    International Nuclear Information System (INIS)

    Chi Xiaohua; Li Guiping; Liu Feng; Wang Bing; Du Li; Deng Zhifang; Li Wei

    2013-01-01

    Background: Diabetes nephropathy is a common complication of diabetes mellitus patients. Early detection of renal impairment can improve the quality of life of patients. Purpose: The value of total GFR, serum creatinine, 24-hour urine protein excretion in diabetes mellitus patients with renal impairment were evaluated. Methods: A retrospective analysis of 147 patients with diabetes undergoing routine renal dynamic imaging was undertaken. The cases were divided into three groups according to the illness duration: group I of not more than five years, group 2 of five to ten years, Gr.3: more than ten years. The 22 renal transplant donors were selected as the normal control group, The total GFR, serum creatinine and 24-hour urinary protein excretion of all patients were measured before the treatments, and the data were statistically analyzed. Results: There was no significant differences in renal function between the two kidneys of in the diabetes mellitus patients (P=0.536). Serum creatinine and total GFR had significant correlation (R 2 =0.762), but no significant relationship between the 24-hour urine protein and the total GFR or serum creatinine. In the early and middle times of renal function impairment, the total GFR and serum creatinine have significant difference in different time periods (P<0.05). During the mid-late times of renal function impairment, total GFR and serum creatinine have no statistically significant differences (P value is 0.781, 0.297). 24-hour urine protein quality had no statistical differences in each stage. However: the total GFR is more sensitive than the serum creatinine in evaluation of early impairing of renal function. Conclusions: There is significant correlation between serum creatinine and total GFR. Both of them can reflect the degree of diabetic renal injury, but the total GFR is more sensitive than serum creatinine in early degree. 24-hour urine protein quantitative can not evaluate the degree of impaired renal function alone

  6. Interferences of homogentisic acid (HGA) on routine clinical chemistry assays in serum and urine and the implications for biochemical monitoring of patients with alkaptonuria.

    Science.gov (United States)

    Curtis, S L; Roberts, N B; Ranganath, L R

    2014-05-01

    We have assessed the effect of elevated concentrations of homogentisic acid (HGA) as in alkaptonuria (AKU), on a range of routine chemistry tests in serum and urine. HGA was added to pooled serum and a range of assays was analysed with Roche Modular chemistries. Effects on urine were assessed by diluting normal urine with urine from a patient with AKU, adding HGA to urine and after lowering output of urinary HGA with nitisinone treatment. Serum enzymatic creatinine showed 30% negative interference with 100μmol/L HGA and >50% at 400μmol/L. Serum urate 100 to 480μmol/L was reduced up to 20% at 100 and to 50% with 400μmol/L HGA. Serum cholesterol between 3 and 11mmol/L was reduced by 0.5mmol/L with 400μmol/L HGA. Urine enzymatic creatinine and urate with >2mmol/L HGA showed concentration dependent negative interference up to 80%. A positive interference in urine total protein by benzethonium turbidometric assay was observed, with 10mmol/L HGA equivalent to 1g/L protein. Jaffe creatinine, Na, K, Cl, Mg, Ca, phosphate, ALT, GGT, ALP activities and urea in serum and or urine were not affected by increases in HGA. To avoid interferences by HGA in alkaptonuria concentration of HGA should be established before samples are assayed with peroxidase assays and benzethonium urine protein. Copyright © 2013 The Canadian Society of Clinical Chemists. All rights reserved.

  7. Combined determination of serum type IV collagen with urine Tamm-Horsfall protein and albumin for early diagnosis in diabetic retinopathy

    International Nuclear Information System (INIS)

    Wang Hong; Zhang Aihua; Ren Yuguo

    2003-01-01

    Objective: To study the relationship between changes of serum type IV collagen, urine Tamm-horsfall protein, albumin and development of diabetic retinopathy (DR) in patients with type 2 diabetes mellitus. Methods: Serum CIV, urine THP and Alb were determined with ELISA and RIA respectively in 76 patients with type 2 diabetes mellitus (NDR26, BDR26, PDR24) and 30 controls. Results: Values of the three markers were significantly different among the three groups of patients (p < 0.01; p < 0.01; p < 0.001 respectively). Conclusion: Serum type IV collagens, urine Tamm-Horsfall protein and albumin were sensitive indicators in predicting diabetic retinopathy

  8. Driving under the influence of drugs -- evaluation of analytical data of drugs in oral fluid, serum and urine, and correlation with impairment symptoms.

    Science.gov (United States)

    Toennes, Stefan W; Kauert, Gerold F; Steinmeyer, Stefan; Moeller, Manfred R

    2005-09-10

    A study was performed to acquire urine, serum and oral fluid samples in cases of suspected driving under the influence of drugs of abuse. Oral fluid was collected using a novel sampling/testing device (Dräger DrugTest System). The aim of the study was to evaluate oral fluid and urine as a predictor of blood samples positive for drugs and impairment symptoms. Analysis for cannabinoids, amphetamine and its derivatives, opiates and cocaine was performed in urine using the Mahsan Kombi/DOA4-test, in serum using immunoassay and gas chromatography-mass spectrometry (GC-MS) confirmation and in oral fluid by GC-MS. Police and medical officer observations of impairment symptoms were rated and evaluated using a threshold value for the classification of driving inability. Accuracy in correlating drug detection in oral fluid and serum were >90% for all substances and also >90% in urine and serum except for THC (71.0%). Of the cases with oral fluid positive for any drug 97.1% of corresponding serum samples were also positive for at least one drug; of drug-positive urine samples this were only 82.4%. In 119 of 146 cases, impairment symptoms above threshold were observed (81.5%). Of the cases with drugs detected in serum, 19.1% appeared not impaired which were the same with drug-positive oral fluid while more persons with drug-positive urine samples appeared uninfluenced (32.7%). The data demonstrate that oral fluid is superior to urine in correlating with serum analytical data and impairment symptoms of drivers under the influence of drugs of abuse.

  9. Epstein-Barr virus antibodies in serum and DNA load in saliva are not associated with radiological or clinical disease activity in patients with early multiple sclerosis.

    Directory of Open Access Journals (Sweden)

    René M Gieß

    Full Text Available To investigate the association of Epstein-Barr virus (EBV nuclear antigen-1 (EBNA-1 and viral capsid antigen (VCA immunoglobulin (IgG antibodies in serum as well as EBV DNA load in saliva with radiological and clinical disease activity in patients with clinically isolated syndrome (CIS and early relapsing-remitting MS (RRMS.EBNA-1 and VCA immunoglobulin (IgG antibodies were determined in serum of 100 patients with CIS/early RRMS and 60 healthy controls. EBV DNA load was measured in saliva of 48 patients and 50 controls. Patients underwent clinical assessment with the Expanded Disability Status Scale (EDSS and 3 Tesla magnetic resonance imaging at baseline and after a median of 20 months of follow-up (n = 63 for MRI, n = 71 for EDSS. The association of EBV parameters with occurrence of a second relapse, indicating conversion to clinically definite MS (CDMS, was evaluated over a median of 35 months of follow-up after the first clinical event (n = 89.EBNA-1 IgG antibody frequency (p = 0.00005 and EBNA-1 and VCA IgG antibody levels (p<0.0001 for both were higher in patients than in controls. EBV DNA load in saliva did not differ between groups. Neither EBV antibody levels nor DNA load in saliva were associated with baseline or follow-up number or volume of T2-weighted (T2w or contrast enhancing lesions, number of Barkhof criteria or the EDSS, or with the number of new T2w lesions, T2w lesion volume change or EDSS change on follow-up. Likewise, levels of EBV IgG antibodies in serum and DNA load in saliva were not associated with conversion to CDMS.While these findings confirm the association of EBV infection with early MS, neither EBNA-1 nor VCA IgG antibodies in serum nor EBV DNA load in saliva were associated with radiological or clinical disease activity in patients with CIS/early RRMS. These data are compatible with the concept that EBV may be a trigger for MS acting very early during the development of the disease.

  10. Multiple sclerosis test or the 4 humors: cerebrospinal fluid serum, tears and saliva

    International Nuclear Information System (INIS)

    Oehninger Gatti, C.; Buzo Del Puerto, R.; Chouza Antelo, C.; Scotti Bianchi, C.; Cibils, D.; Alcantara Pelaez, J.; Gomez, A.; Heuguerot Oliveira, C.

    1994-01-01

    4 were studied biological fluids easily accessible to the immune exploration (cerebrospinal fluid, serum, tears and saliva) in 25 patients with Multiple Sclerosis (MS) during a push clinical disease. The level of interleukin-2 receptor soluble (RsIL-2) was significantly increased by at least 3 of these 4 fluids, compared with normal controls. The sensitivity and specificity of its determination for the diagnosis of the condition was higher than other immunochemical parameters, oligoclonal distribution (OD) of immunoglobulin (Ig) light chain imbalance-and-evoked electrophysiological studies. This method is used to establish a more accurate diagnosis of Multiple Sclerosis as well as to monitor its biological activity with nuclear magnetic resonance (NMR) (Author) [es

  11. Metabolomic biomarkers in serum and urine in women with preeclampsia

    OpenAIRE

    Austdal, Marie; Skråstad, Ragnhild; Gundersen, Astrid; Austgulen, Rigmor; Iversen, Ann-Charlotte; Bathen, Tone Frost

    2014-01-01

    Objective To explore the potential of magnetic resonance (MR) metabolomics for study of preeclampsia, for improved phenotyping and elucidating potential clues to etiology and pathogenesis. Methods Urine and serum samples from pregnant women with preeclampsia (n = 10), normal pregnancies (n = 10) and non-pregnant women (n = 10) matched by age and gestational age were analyzed with MR spectroscopy and subjected to multivariate analysis. Metabolites were then quantified and compared ...

  12. Detection of trace fluoride in serum and urine by online membrane-based distillation coupled with ion chromatography.

    Science.gov (United States)

    Lou, Chaoyan; Guo, Dandan; Wang, Nani; Wu, Shuchao; Zhang, Peimin; Zhu, Yan

    2017-06-02

    An online membrane-based distillation (MBD) coupled with ion chromatography (IC) method was proposed for automatic detection of trace fluoride (F - ) in serum and urine samples. The system consisted of a sample vessel, a lab-made membrane module and an ion chromatograph. Hydrophobic polytetrafluoroethylene (PTFE) hollow fiber membrane was used in MBD which was directly performed in serum and urine samples to eliminate the matrix interferences and enrich fluoride, while enabling automation. The determination of fluoride in biological samples was carried out by IC with suppressed conductometric detection. The proposed method feasibly determined trace fluoride in serum and urine matrices with the optimized parameters, such as acid concentration, distillation temperature, and distillation time, etc. Fluoride exhibited satisfactory linearity in the range of 0.01-5.0mg/L with a correlation coefficient of 0.9992. The limit of detection (LOD, S/N=3) and limit of quantification (LOQ, S/N=10) were 0.78μg/L and 2.61μg/L, respectively. The relative standard deviations of peak area and peak height were all less than 5.15%. The developed method was validated for the determination of fluoride in serum and urine with good spiked recoveries ranging between 97.1-101.9%. This method also can be proposed as a suitable alternative for the analysis of fluoride in other complex biological samples. Copyright © 2017. Published by Elsevier B.V.

  13. Relationship between water, urine and serum fluoride and fluorosis in school children of Jhajjar District, Haryana, India

    Science.gov (United States)

    Kumar, Sunil; Lata, Suman; Yadav, Jyoti; Yadav, J. P.

    2017-10-01

    The present study was undertaken to determine the relationship between fluoride in water, urine and serum and dental fluorosis. The fluoride level in water and urine were measured spectrophotometrically by using acid zirconyl and SPADNS reagents, while the fluoride level in serum was determined by ion selective electrode meter. Dental fluorosis survey was conducted with the help of Performa prescribed by Rajiv Gandhi Drinking Water Mission and the use of Tooth Surface Index for Fluorosis. Mean fluoride values in water samples of Jhajjar City and Dadanpur and Dariyapur villages of Jhajjar District were measured to be 2.17 (range from 1.92 to 2.60 mg/L), 2.81 (range from 2.53 to 3.14 mg/L) and 2.22 mg/L (range from 1.63 to 3.33 mg/L), respectively. The mean fluoride values in the urine samples of children were found to be 1.51 (range from 0.05 to 2.64 mg/L), 1.71 (range from 0.69 to 2.80 mg/L) and 1.45 mg/L (range from 0.31 to 2.50 mg/L) at Jhajjar City and Dadanpur and Dariyapur sites, respectively. Serum fluoride was detected in the blood samples of children, who have high urinary fluoride at these three sites. The mean serum fluoride level was reported to be 0.15, 0.34 and 0.17 mg/L, respectively. A total of 842 children were also analyzed for dental fluorosis. The mean values of fluorosis-affected children in Jhajjar, Dadanpur and Dariyapur were 51.90, 94.63 and 36.84 %, respectively. A significantly positive correlation between water, urine, serum fluoride concentration and fluorosis was seen.

  14. Liquid chromatographic determination of pioglitazone in pharmaceuticals, serum and urine samples

    International Nuclear Information System (INIS)

    Abro, K.; Memon, N.; Bhanger, M.I.; Mahesar, S.A.; Parveen, S.

    2011-01-01

    A rapid and reliable analytical method based on high-performance liquid chromatography (HPLC) with UV detection (221 nm) has been developed for the determination of the anti-hyper glycemic agent Pioglitazone in pharmaceutical formulations and biological fluids (serum and urine) after clean-up with solid-phase extraction. Chromatographic separation was achieved with a Chromolith Performance RP-18e (10 4.6mm) column using mobile phase composition of acetonitrile: mixed phosphate buffer (pH 2.5; 10mM) (30:70, v/v) with a flow rate of 2.0mL/min. The total run time was 2 min. under optimized conditions. The calibration curve was found to be linear in the range of 1-10 mu g mL/sup -1/ with regression coefficient of 0.9996, and the lower limit of detection 72 ng/20 mu L injection. The method has been validated for the system suitability, linearity, precision and accuracy, limits of detection, specificity, stability and robustness. The %recovery of Pioglitazone in pharmaceutical formulations was found to be 104.7%. The assay has been applied successfully to the pharmaceutical Tablet samples and biological fluids (serum and urine) of healthy volunteers. (author)

  15. Aluminum concentrations in serum, dialysate, urine and bone among patients undergoing continuous ambulatory peritoneal dialysis (CAPD)

    DEFF Research Database (Denmark)

    Joffe, P; Olsen, F; Heaf, J G

    1989-01-01

    Aluminum (Al) concentration in serum, urine, and dialysate was estimated in 21 patients undergoing continuous ambulatory peritoneal dialysis (CAPD). In 12 of the patients bone Al concentration was measured as well. Mean serum Al level was 32.4 +/- 21.0 micrograms/l. The Al concentrations in the d...

  16. Profiles of bile acids and their glucuronide and sulphate conjugates in the serum, urine and bile from patients undergoing bile drainage.

    OpenAIRE

    Takikawa, H; Beppu, T; Seyama, Y

    1985-01-01

    Bile acid profiles in serum, urine, and bile from patients undergoing bile drainage and the changes of serum bile acids after bile drainage were studied. Bile acids were separated into non-glucuronidate-non-sulphate, glucuronidated, and sulphated fractions and were measured by mass fragmentography using conjugates of deuterium labelled bile acids as internal standards. Glucuronidated and sulphated bile acids contribute 14-32% and 16-44% of serum bile acids, 4-11% and 61-82% of urine bile acid...

  17. Spectrophotometric determination of metformin in pharmaceutical preparations, serum and urine using benzoin as derivatizing reagent

    International Nuclear Information System (INIS)

    Alamgir, M.; Hayat, A.

    2014-01-01

    A simple and selective spectrophotometric procedure is described for the determination of Metformin based on derivatization with benzoin. The Beers law was obeyed with 2.50-12.50 meu mol L-1 at 290 nm with coefficient of determination (r2) 0.997. The experimental conditions in term of pH, reaction time and temperature, and addition of derivatizing reagent were examined. The pure metformin-benzoin derivative was prepared and characterized by FT-IR and mass spectroscopic techniques. The method was applied for the determination of metformin from pharmaceutical preparations and serum and urine of volunteers after spiking with metformin. The results were checked by standard addition method. A number of pharmaceutical additives and serum or urine matrix did not affect the determination of metformin. (author)

  18. GC/TOFMS analysis of metabolites in serum and urine reveals metabolic perturbation of TCA cycle in db/db mice involved in diabetic nephropathy.

    Science.gov (United States)

    Li, Mengjie; Wang, Xufang; Aa, Jiye; Qin, Weisong; Zha, Weibin; Ge, Yongchun; Liu, Linsheng; Zheng, Tian; Cao, Bei; Shi, Jian; Zhao, Chunyan; Wang, Xinwen; Yu, Xiaoyi; Wang, Guangji; Liu, Zhihong

    2013-06-01

    Early diagnosis of diabetic nephropathy (DN) is difficult although it is of crucial importance to prevent its development. To probe potential markers and the underlying mechanism of DN, an animal model of DN, the db/db mice, was used and serum and urine metabolites were profiled using gas chromatography/time-of-flight mass spectrometry. Metabolic patterns were evaluated based on serum and urine data. Principal component analysis of the data revealed an obvious metabonomic difference between db/db mice and controls, and db/db mice showed distinctly different metabolic patterns during the progression from diabetes to early, medium, and later DN. The identified metabolites discriminating between db/db mice and controls suggested that db/db mice have perturbations in the tricarboxylic acid cycle (TCA, citrate, malate, succinate, and aconitate), lipid metabolism, glycolysis, and amino acid turnover. The db/db mice were characterized by acidic urine, high TCA intermediates in serum at week 6 and a sharp decline thereafter, and gradual elevation of free fatty acids in the serum. The sharp drop of serum TCA intermediates from week 6 to 8 indicated the downregulated glycolysis and insulin resistance. However, urinary TCA intermediates did not decrease in parallel with those in the serum from week 6 to 10, and an increased portion of TCA intermediates in the serum was excreted into the urine at 8, 10, and 12 wk than at 6 wk, indicating kidney dysfunction occurred. The relative abundances of TCA intermediates in urine relative to those in serum were suggested as an index of renal damage.

  19. Detection of Wuchereria bancrofti DNA in paired serum and urine samples using polymerase chain reaction-based systems

    Directory of Open Access Journals (Sweden)

    Camila Ximenes

    2014-12-01

    Full Text Available The Global Program for the Elimination of Lymphatic Filariasis (GPELF aims to eliminate this disease by the year 2020. However, the development of more specific and sensitive tests is important for the success of the GPELF. The present study aimed to standardise polymerase chain reaction (PCR-based systems for the diagnosis of filariasis in serum and urine. Twenty paired biological urine and serum samples from individuals already known to be positive for Wuchereria bancrofti were collected during the day. Conventional PCR and semi-nested PCR assays were optimised. The detection limit of the technique for purified W. bancrofti DNA extracted from adult worms was 10 fg for the internal systems (WbF/Wb2 and 0.1 fg by using semi-nested PCR. The specificity of the primers was confirmed experimentally by amplification of 1 ng of purified genomic DNA from other species of parasites. Evaluation of the paired urine and serum samples by the semi-nested PCR technique indicated only two of the 20 tested individuals were positive, whereas the simple internal PCR system (WbF/Wb2, which has highly promising performance, revealed that all the patients were positive using both samples. This study successfully demonstrated the possibility of using the PCR technique on urine for the diagnosis of W. bancrofti infection.

  20. Comparing Serum and 24-hour Urine Calcium between Preeclamptic and Non-preeclamptic Patients

    Directory of Open Access Journals (Sweden)

    N Shahbazian

    2014-02-01

    Results: No statistically significant difference was found between serum calcium means in the two groups (p=0.07, though mean of 24-hour urine calcium in preeclamptic patients was significantly lower than that of control group (p=0.0003. In preeclamptic group, the degree of hypocalciuria was related to disordered liver enzymes, serum creatinine greater than 1.2 mg/dl, thrombocytopenia and proteinuria more than 2g/24h. Conclusion: Preeclampsia is associated with hypocalciuria; the more hypocalciuria there exists , the more preeclampsia is observed.

  1. Paired Serum and Urine Concentrations of Biomarkers of Diethyl Phthalate, Methyl Paraben, and Triclosan in Rats

    Science.gov (United States)

    Teitelbaum, Susan L.; Li, Qian; Lambertini, Luca; Belpoggi, Fiorella; Manservisi, Fabiana; Falcioni, Laura; Bua, Luciano; Silva, Manori J.; Ye, Xiaoyun; Calafat, Antonia M.; Chen, Jia

    2015-01-01

    Background Exposure to environmental chemicals, including phthalates and phenols such as parabens and triclosan, is ubiquitous within the U.S. general population. Objective This proof-of-concept rodent study examined the relationship between oral doses of three widely used personal care product ingredients [diethyl phthalate (DEP), methyl paraben (MPB), and triclosan] and urine and serum concentrations of their respective biomarkers. Methods Using female Sprague-Dawley rats, we carried out two rounds of experiments with oral gavage doses selected in accordance with no observed adverse effect levels (NOAELs) derived from previous studies: 1,735 (DEP), 1,050 (MPB), 50 (triclosan) mg/kg/day. Administered doses ranged from 0.005 to 173 mg/kg/day, 10–100,000 times below the NOAEL for each chemical. Controls for the MPB and triclosan experiments were animals treated with olive oil (vehicle) only; controls for the DEP serum experiments were animals treated with the lowest doses of MPB and triclosan. Doses were administered for 5 days with five rats in each treatment group. Urine and blood serum, collected on the last day of exposure, were analyzed for biomarkers. Relationships between oral dose and biomarker concentrations were assessed using linear regression. Results Biomarkers were detected in all control urine samples at parts-per-billion levels, suggesting a low endemic environmental exposure to the three chemicals that could not be controlled even with all of the precautionary measures undertaken. Among the exposed animals, urinary concentrations of all three biomarkers were orders of magnitude higher than those in serum. A consistently positive linear relationship between oral dose and urinary concentration was observed (R2 > 0.80); this relationship was inconsistent in serum. Conclusions Our study highlights the importance of carefully considering the oral dose used in animal experiments and provides useful information in selecting doses for future studies

  2. Performance of polymerase chain reaction for the diagnosis of cystic echinococcosis using serum, urine, and cyst fluid samples.

    Science.gov (United States)

    Chaya, Dr; Parija, Subhash Chandra

    2014-01-01

    Cystic echinococcosis (CE) is a chronic zoonosis which presents with variable clinical manifestations. Currently the diagnosis of this disease is based on radiological findings and serological tests which lack specificity. Although antigen detection from the cyst fluid is the most specific, it is seldom done due to the complications involved. Detecting the presence of Echinococcus granulosus specific deoxyribonucleic acid (DNA) by the polymerase chain reaction (PCR) could provide a definitive diagnosis of CE. An in-house PCR assay was devised to detect E. granulosus specific DNA in serum, urine and hydatid cyst fluid. The ability of the PCR to detect E. granulosus in the above mentioned samples were observed in comparison with other antigen and antibody detection tests. Serum samples from surgically confirmed patients of CE with ruptured cysts contained the corresponding DNA while the in the majority of cases who had an intact cyst had no DNA of E. granulosus in their serum. DNA of E. granulosus was not found to be excreted in urine. PCR performed equal to antigen detection ELISA while testing hydatid cyst fluid samples. Serum and urine might not serve as useful samples for the molecular diagnosis of cystic echinococcosis. However, PCR can be useful on serum samples to detect ruptured hydatid cysts and on hydatid cyst fluid to confirm the parasitic diagnosis.

  3. Clinical significance of changes of serum APN, plasma VEGF, Hcy and urine albumin levels in patients with DM2 nephrosis

    International Nuclear Information System (INIS)

    Zhang Yuejin; Zhang Xinfang; Hu Ying

    2011-01-01

    Objective: Explore type 2 diabetes mellitus (DM2) and complicating with kidney disease patients homocysteine (Hcy), adiponectin (APN), vascular endothelial growth factor (VEGF) and urine albumin change relations. Methods: A normal controls and no complications of diabetes groups, combined with nephropathy. A comparison were measured of serum APN, plasma VEGF, Hcy and urine albumin level among. Results: Two groups of patients with diabetes fasting blood glucose level were no significant difference. Also there is no difference of BUN and Cr in three groups urine albumin in diabetic-nephropathy albumin increased significantly (P<0.01), than without complications group. Three groups of Hcy concentrations were significantly higher than that of normal control group (P<0.01), serum APN, plasma VEGF level obviously lower than normal control group, which increased in patients with nephropathy increased or reduced more apparently no complications group also have obvious difference (P<0.01). Conclusion: In patients with diabetes in two groups, plasma Hcy and urine albumin were significantly higher APN, and VEGF decreased significantly. In patients with nephropathy manifested more apparently, but renal damage did not enter decompensated period, clinically necessary for people with diabetes testing serum APN, plasma VEGF, Hcy and urine Albumin level, promptly intervention to prevent or relieve the further development of diabetes. (authors)

  4. Comparison of Plasma, Saliva, and Hair Levetiracetam Concentrations.

    Science.gov (United States)

    Karaś-Ruszczyk, Katarzyna; Kuczyńska, Julita; Sienkiewicz-Jarosz, Halina; Kurkowska-Jastrzębska, Iwona; Bienkowski, Przemyslaw; Restel, Magdalena; Samochowiec, Jerzy; Mierzejewski, Pawel

    2017-06-01

    Previous findings revealed high correlations between serum/plasma and saliva levetiracetam concentrations, indicating saliva as an alternative matrix for monitoring levetiracetam therapy. Levetiracetam concentration in the hair, which could reflect long-term drug exposure and patients' compliance, has not been systematically tested, as yet. The aim of this study was to determine the correlation between plasma, saliva, and hair levetiracetam concentrations in 47 patients with epilepsy. Plasma, saliva, and hair levetiracetam concentrations were measured by liquid chromatography-tandem mass spectrometry with positive ionization. Levetiracetam saliva and plasma concentrations were highly correlated (r = 0.93). Plasma concentrations were not influenced by sex, age, and other concomitant antiepileptic drugs. Levetiracetam hair concentrations correlated with plasma concentrations (r = 0.36) but not daily dose (mg/kg). Drug hair concentrations were not influenced by hair color or treatment (dyed). The results tend to indicate that saliva may be a reliable alternative to plasma for monitoring levetiracetam concentrations. Levetiracetam can also be detected in human hair.

  5. Factors determining the passage of drugs from blood into saliva.

    OpenAIRE

    Stephen, K W; McCrossan, J; Mackenzie, D; Macfarlane, C B; Speirs, C F

    1980-01-01

    1. Following single oral dosing of ampicillin, cephalexin, tetracycline, erythromycin estolate, clindamycin and rifampicin to six normal volunteers, antibacterial activity was measured at 1, 3 and 6 h in serum, gingival fluid and minor gland saliva from all subjects and in parotid and submandiabular saliva from three. 2. pH values of all gingival fluid and saliva specimens were noted. 3. Partition coefficients between n-octanol and water were measured for erythromycin, clindamycin and rifampi...

  6. Speciation analysis of arsenic compounds in the serum and urine of a patient with acute arsine poisoning

    Directory of Open Access Journals (Sweden)

    Yamanaka K.

    2013-04-01

    Full Text Available Arsine is one of the most potent hemolytic agents. It is important to clarify arsine metabolism as well as its chemical interactions with biological components. The aim of the present study was to clarify arsine metabolism by arsenic speciation analysis in serum and urine from an acute poisoning patient with hematuria, anemia, and renal and liver dysfunction. Speciation analysis of arsenics in serum and urine was performed using HPLC-ICP-MS. The total arsenic (T-As concentration in serum was 244.8 μg/l at admission and 97.1 μg/l at discharge. In the speciation analysis, four kinds of As compounds derived from arsine metabolism were detected in serum and urine. The concentration of arsenite (AsIII, arsenate (AsV, monomethylarsonic acid (MMA, and dimethylarsinic acid (DMA in serum at admission were 45.8, 5.2, 17.9 and 9.3 μg/l, respectively. The concentrations of AsIII, AsV, and MMA decreased with biological half time (BHT of 30.1, 43.0, and 96.3 h, respectively. Only DMA was increased at discharge. The urinary AsIII, AsV, MMA and DMA concentrations were 223.0, 12.1, 317.5 and 1053.5 μg/l at discharge, and decreased with BHT of 15.1, 20.8, 14.7, and 16.0 d, respectively. The results indicate that arsine was quickly metabolized to AsIII and subsequently up to DMA, with the result that the toxic effects of inorganic arsenic were added to those of arsine toxicity.

  7. Gas chromatography-mass spectrometry/mass spectrometry analysis to determine natural and post-administration levels of oestrogens in bovine serum and urine

    International Nuclear Information System (INIS)

    Biddle, S.; Teale, P.; Robinson, A.; Bowman, J.; Houghton, E.

    2007-01-01

    A novel analytical approach has been developed and shown to be capable of detecting the isomers of oestradiol in the low ppt (pg mL -1 ) range in bovine serum and urine. Following extractive derivatisation the analytes were detected as their 3-pentafluorobenzoyl 17-trimethylsilyl ether derivatives by gas chromatography-mass spectrometry/mass spectrometry (GC-MS/MS), using electron capture negative ion chemical ionisation. The isomers of oestradiol were quantified in both blank and post-administration urine and serum samples, with a view to setting action/threshold levels for these compounds, to allow discrimination between normal samples and samples from animals treated with growth promoting ear implants. A non-parametric statistical assessment of the data resulted in proposed action levels (with a false positive probability of 1 in 1000) of 1.6 and 2.7 ng mL -1 for 17α-oestradiol, in male and female urine, respectively, and 40 and 44 pg mL -1 for 17β-oestradiol, in male and female urine, respectively. An action level of 20 pg mL -1 was proposed for 17α- and 17β-oestradiol in male serum. In female serum the proposed action levels were 40 and 20 pg mL -1 for 17α- and 17β-oestradiol, respectively

  8. Determination of ethyl sulfate in human serum and urine by capillary zone electrophoresis.

    Science.gov (United States)

    Jung, Balthasar; Caslavska, Jitka; Thormann, Wolfgang

    2008-10-03

    The use of capillary zone electrophoresis (CZE) with indirect absorbance detection for the analysis of ethyl sulfate (EtS) in serum and urine was investigated. EtS is a direct metabolite of ethanol employed as marker for recent alcohol consumption. Fused-silica capillaries of 60 cm total length were either coated with cetyltrimethylammonium bromide (CTAB, 50 microm I.D. capillary) or poly(diallyldimethylammonium chloride) (PDADMAC, 100 microm I.D. capillary) to allow CZE analyses to be performed with reversed polarity. At pH 2.2 with a maleic acid/phthalic acid background electrolyte, both approaches provided reliable EtS serum levels down to 0.2 mg L(-1) (1.6 microM) for the analysis of solid-phase extracts that were prepared after chloride precipitation. Analysis of urines diluted to a conductivity of 5 S m(-1) and analyzed in the two capillary formats resulted in limits of quantification (LOQs) of 2 and 1 mg L(-1), respectively. With urines adjusted to 10 S m(-1) via dilution or condensation, an LOQ of 0.6 mg L(-1) (4.8 microM) was obtained in the CTAB coated capillary whereas in the PDADMAC-coated capillary of equal length not all matrix components were resolved from EtS. The developed assays are robust and suitable to monitor EtS in samples of individuals who consumed as little as one standard drink of an alcoholic beverage containing about 14 g of ethanol.

  9. First Trimester Urine and Serum Metabolomics for Prediction of Preeclampsia and Gestational Hypertension: A Prospective Screening Study.

    Science.gov (United States)

    Austdal, Marie; Tangerås, Line H; Skråstad, Ragnhild B; Salvesen, Kjell; Austgulen, Rigmor; Iversen, Ann-Charlotte; Bathen, Tone F

    2015-09-08

    Hypertensive disorders of pregnancy, including preeclampsia, are major contributors to maternal morbidity. The goal of this study was to evaluate the potential of metabolomics to predict preeclampsia and gestational hypertension from urine and serum samples in early pregnancy, and elucidate the metabolic changes related to the diseases. Metabolic profiles were obtained by nuclear magnetic resonance spectroscopy of serum and urine samples from 599 women at medium to high risk of preeclampsia (nulliparous or previous preeclampsia/gestational hypertension). Preeclampsia developed in 26 (4.3%) and gestational hypertension in 21 (3.5%) women. Multivariate analyses of the metabolic profiles were performed to establish prediction models for the hypertensive disorders individually and combined. Urinary metabolomic profiles predicted preeclampsia and gestational hypertension at 51.3% and 40% sensitivity, respectively, at 10% false positive rate, with hippurate as the most important metabolite for the prediction. Serum metabolomic profiles predicted preeclampsia and gestational hypertension at 15% and 33% sensitivity, respectively, with increased lipid levels and an atherogenic lipid profile as most important for the prediction. Combining maternal characteristics with the urinary hippurate/creatinine level improved the prediction rates of preeclampsia in a logistic regression model. The study indicates a potential future role of clinical importance for metabolomic analysis of urine in prediction of preeclampsia.

  10. First Trimester Urine and Serum Metabolomics for Prediction of Preeclampsia and Gestational Hypertension: A Prospective Screening Study

    Directory of Open Access Journals (Sweden)

    Marie Austdal

    2015-09-01

    Full Text Available Hypertensive disorders of pregnancy, including preeclampsia, are major contributors to maternal morbidity. The goal of this study was to evaluate the potential of metabolomics to predict preeclampsia and gestational hypertension from urine and serum samples in early pregnancy, and elucidate the metabolic changes related to the diseases. Metabolic profiles were obtained by nuclear magnetic resonance spectroscopy of serum and urine samples from 599 women at medium to high risk of preeclampsia (nulliparous or previous preeclampsia/gestational hypertension. Preeclampsia developed in 26 (4.3% and gestational hypertension in 21 (3.5% women. Multivariate analyses of the metabolic profiles were performed to establish prediction models for the hypertensive disorders individually and combined. Urinary metabolomic profiles predicted preeclampsia and gestational hypertension at 51.3% and 40% sensitivity, respectively, at 10% false positive rate, with hippurate as the most important metabolite for the prediction. Serum metabolomic profiles predicted preeclampsia and gestational hypertension at 15% and 33% sensitivity, respectively, with increased lipid levels and an atherogenic lipid profile as most important for the prediction. Combining maternal characteristics with the urinary hippurate/creatinine level improved the prediction rates of preeclampsia in a logistic regression model. The study indicates a potential future role of clinical importance for metabolomic analysis of urine in prediction of preeclampsia.

  11. Gas chromatography-mass spectrometry/mass spectrometry analysis to determine natural and post-administration levels of oestrogens in bovine serum and urine

    Energy Technology Data Exchange (ETDEWEB)

    Biddle, S. [HFL, Newmarket Road, Fordham, Cambridgeshire (United Kingdom)]. E-mail: sbiddle@hfl.co.uk; Teale, P. [HFL, Newmarket Road, Fordham, Cambridgeshire (United Kingdom); Robinson, A. [HFL, Newmarket Road, Fordham, Cambridgeshire (United Kingdom); Bowman, J. [HFL, Newmarket Road, Fordham, Cambridgeshire (United Kingdom); Houghton, E. [HFL, Newmarket Road, Fordham, Cambridgeshire (United Kingdom)

    2007-03-14

    A novel analytical approach has been developed and shown to be capable of detecting the isomers of oestradiol in the low ppt (pg mL{sup -1}) range in bovine serum and urine. Following extractive derivatisation the analytes were detected as their 3-pentafluorobenzoyl 17-trimethylsilyl ether derivatives by gas chromatography-mass spectrometry/mass spectrometry (GC-MS/MS), using electron capture negative ion chemical ionisation. The isomers of oestradiol were quantified in both blank and post-administration urine and serum samples, with a view to setting action/threshold levels for these compounds, to allow discrimination between normal samples and samples from animals treated with growth promoting ear implants. A non-parametric statistical assessment of the data resulted in proposed action levels (with a false positive probability of 1 in 1000) of 1.6 and 2.7 ng mL{sup -1} for 17{alpha}-oestradiol, in male and female urine, respectively, and 40 and 44 pg mL{sup -1} for 17{beta}-oestradiol, in male and female urine, respectively. An action level of 20 pg mL{sup -1} was proposed for 17{alpha}- and 17{beta}-oestradiol in male serum. In female serum the proposed action levels were 40 and 20 pg mL{sup -1} for 17{alpha}- and 17{beta}-oestradiol, respectively.

  12. Monoclonal antibody-based dipstick assay: a reliable field applicable technique for diagnosis of Schistosoma mansoni infection using human serum and urine samples.

    Science.gov (United States)

    Demerdash, Zeinab; Mohamed, Salwa; Hendawy, Mohamed; Rabia, Ibrahim; Attia, Mohy; Shaker, Zeinab; Diab, Tarek M

    2013-02-01

    A field applicable diagnostic technique, the dipstick assay, was evaluated for its sensitivity and specificity in diagnosing human Schistosoma mansoni infection. A monoclonal antibody (mAb) against S. mansoni adult worm tegumental antigen (AWTA) was employed in dipstick and sandwich ELISA for detection of circulating schistosome antigen (CSA) in both serum and urine samples. Based on clinical and parasitological examinations, 60 S. mansoni-infected patients, 30 patients infected with parasites other than schistosomiasis, and 30 uninfected healthy individuals were selected. The sensitivity and specificity of dipstick assay in urine samples were 86.7% and 90.0%, respectively, compared to 90.0% sensitivity and 91.7% specificity of sandwich ELISA. In serum samples, the sensitivity and specificity were 88.3% and 91.7% for dipstick assay vs. 91.7% and 95.0% for sandwich ELISA, respectively. The diagnostic efficacy of dipstick assay in urine and serum samples was 88.3% and 90.0%, while it was 90.8% and 93.3% for sandwich ELISA, respectively. The diagnostic indices of dipstick assay and ELISA either in serum or in urine were statistically comparable (P>0.05). In conclusion, the dipstick assay offers an alternative simple, rapid, non-invasive technique in detecting CSA or complement to stool examinations especially in field studies.

  13. Erosion protection conferred by whole human saliva, dialysed saliva, and artificial saliva

    Science.gov (United States)

    Baumann, T.; Kozik, J.; Lussi, A.; Carvalho, T. S.

    2016-10-01

    During dental erosion, tooth minerals are dissolved, leading to a softening of the surface and consequently to irreversible surface loss. Components from human saliva form a pellicle on the tooth surface, providing some protection against erosion. To assess the effect of different components and compositions of saliva on the protective potential of the pellicle against enamel erosion, we prepared four different kinds of saliva: human whole stimulated saliva (HS), artificial saliva containing only ions (AS), human saliva dialysed against artificial saliva, containing salivary proteins and ions (HS/AS), and human saliva dialysed against deionised water, containing only salivary proteins but no ions (HS/DW). Enamel specimens underwent four cycles of immersion in either HS, AS, HS/AS, HS/DW, or a humid chamber (Ctrl), followed by erosion with citric acid. During the cycling process, the surface hardness and the calcium released from the surface of the specimens were measured. The different kinds of saliva provided different levels of protection, HS/DW exhibiting significantly better protection than all the other groups (p < 0.0001). Different components of saliva, therefore, have different effects on the protective properties of the pellicle and the right proportions of these components in saliva are critical for the ability to form a protective pellicle.

  14. Evaluation of the iodine concentration in serum and urine of hypothyroid males an inexpensive and rapid method

    International Nuclear Information System (INIS)

    Kandhro, G.A.; Kazi, T.G.; Sirajuddin; Afridi, H.I.; Baig, J.A.; Shah, A.Q.; Arain, M.B.

    2009-01-01

    The aim of present study was to evaluate the iodine/iodide status in biological samples (serum and urine) of 172 male hypothyroid patients (HPs) and their supplemental effects on thyroid hormones. For comparison purpose, non-goitrous subjects (n= 220) of same age group and socioeconomic status were also studied. A simple and rapid iodide-ion selective electrode (ISE) was used to measure the concentration of iodine in microwave assisted acid digested serum and urine samples. Quality control for the methodology was established with certified samples and with those obtained by conventional wet acid digestion method on the same certified reference materials (CRMs) and real samples. A linear calibration curve was obtained for a reasonable concentration range of the potassium iodide solutions. The mean concentration of iodine in the serum and urine samples of the HPs was significantly reduced as compared to control male subjects (p< 0.01). The low levels of free triiodothyronine and thyroxin were found in HPs than age matched healthy control (p< 0.005 and 0.002) respectively while high levels of thyroid stimulating hormone were observed in HPs (p< 0.008). The proposed method was relatively efficient as well as cost effective by using inexpensive equipment. It was observed that iodine in biological samples of HPs can play an important role in determining the severity of the hypothyroidism. (author)

  15. Evaluation of U.S. Commercial-Off-the-Shelf Hand-Held Assays to Detect Opiate Pain Reliever Compounds in Multiple Biofluids

    Science.gov (United States)

    2016-09-01

    plasma. The plasma was carefully removed from the tubes and aliquoted before storage at –80 °C. Urine samples were collected using syringes during...serum, urine , saliva, and environmental samples . The limit of detection (LOD) and specificity were also determined for these products. The final...followed the cervical dislocation procedure. Samples were collected from three inoculated rabbits, as shown in Figure 1. Blood, plasma, urine and saliva

  16. Development and validation of a rapid turboflow LC-MS/MS method for the quantification of LSD and 2-oxo-3-hydroxy LSD in serum and urine samples of emergency toxicological cases.

    Science.gov (United States)

    Dolder, Patrick C; Liechti, Matthias E; Rentsch, Katharina M

    2015-02-01

    Lysergic acid diethylamide (LSD) is a widely used recreational drug. The aim of the present study is to develop a quantitative turboflow LC-MS/MS method that can be used for rapid quantification of LSD and its main metabolite 2-oxo-3-hydroxy LSD (O-H-LSD) in serum and urine in emergency toxicological cases without time-consuming extraction steps. The method was developed on an ion-trap LC-MS/MS instrument coupled to a turbulent-flow extraction system. The validation data showed no significant matrix effects and no ion suppression has been observed in serum and urine. Mean intraday accuracy and precision for LSD were 101 and 6.84%, in urine samples and 97.40 and 5.89% in serum, respectively. For O-H-LSD, the respective values were 97.50 and 4.99% in urine and 107 and 4.70% in serum. Mean interday accuracy and precision for LSD were 100 and 8.26% in urine and 101 and 6.56% in serum, respectively. For O-H-LSD, the respective values were 101 and 8.11% in urine and 99.8 and 8.35% in serum, respectively. The lower limit of quantification for LSD was determined to be 0.1 ng/ml. LSD concentrations in serum were expected to be up to 8 ng/ml. 2-Oxo-3-hydroxy LSD concentrations in urine up to 250 ng/ml. The new method was accurate and precise in the range of expected serum and urine concentrations in patients with a suspected LSD intoxication. Until now, the method has been applied in five cases with suspected LSD intoxication where the intake of the drug has been verified four times with LSD concentrations in serum in the range of 1.80-14.70 ng/ml and once with a LSD concentration of 1.25 ng/ml in urine. In serum of two patients, the O-H-LSD concentration was determined to be 0.99 and 0.45 ng/ml. In the urine of a third patient, the O-H-LSD concentration was 9.70 ng/ml.

  17. Radioimmunoassay of lysergic acid diethylamide (LSD) in serum and urine by using antisera of different specificities

    International Nuclear Information System (INIS)

    Ratcliffe, W.A.; Fletcher, S.M.; Moffat, A.C.; Ratcliffe, J.G.; Harland, W.A.; Levitt, T.E.

    1977-01-01

    We raised high-titre antisera to two LSD-bovine serum albumin conjugates, one linked via the indole nitrogen, the other via the amide side-chain. The antisera were specific for different parts of the LSD molecule, as demonstrated by cross-reactivity studies with LSD, its metabolites, ergot alkaloids, and closely related compounds. The antisera were used to develop a double-antibody radioimmunoassay with a detection limit of about 0.4 μg of LSD per liter of unextracted urine or serum. We saw no nonspecific interference by urine, serum, or from a series of commonly used drugs. There was good correlation between immunoassay values obtained with the two antisera (r = 0.91). However, the antiserum linked via the indole nitrogen gave consistently higher results for samples from persons who had taken LSD, owing to greater cross-reactivity with LSD metabolites. Radioimmunoassay by use of two such antisera is a more specific screening procedure for LSD abuse than has been available previously. In addition, antisera cross-reacting with LSD metabolites allow measurement of these compounds, for which there is no satisfactory method at the concentrations found in biological fluids in man

  18. Stability of serum, plasma and urine osmolality in different storage conditions: Relevance of temperature and centrifugation.

    Science.gov (United States)

    Sureda-Vives, Macià; Morell-Garcia, Daniel; Rubio-Alaejos, Ana; Valiña, Laura; Robles, Juan; Bauça, Josep Miquel

    2017-09-01

    Osmolality reflects the concentration of all dissolved particles in a body fluid, and its measurement is routinely performed in clinical laboratories for the differential diagnosis of disorders related with the hydrolytic balance regulation, the renal function and in small-molecule poisonings. The aim of the study was to assess the stability of serum, plasma and urine osmolality through time and under different common storage conditions, including delayed centrifugation. Blood and urine samples were collected, and classified into different groups according to several preanalytical variables: serum or plasma lithium-heparin tubes; spun or unspun; stored at room temperature (RT), at 4°C or frozen at -21°C. Aliquots from each group were assayed over time, for up to 14days. Statistical differences were based on three different international performance criteria. Whole blood stability was higher in the presence of anticoagulant. Serum osmolality was stable for 2days at RT and 8days at 4°C, while plasma was less stable when refrigerated. Urine stability was 5days at RT, 4days at 4°C and >14days when frozen. Osmolality may be of great interest for the management of several conditions, such as in case of a delay in the clinical suspicion, or in case of problems in sample collection or processing. The ability to obtain reliable results for samples kept up to 14days also offers the possibility to retrospectively assess baseline values for patients which may require it. Copyright © 2017. Published by Elsevier Inc.

  19. Correlations between phthalate metabolites in urine, serum, and seminal plasma from young Danish men determined by isotope dilution liquid chromatography tandem mass spectrometry

    DEFF Research Database (Denmark)

    Frederiksen, Hanne; Jørgensen, Niels; Andersson, Anna-Maria

    2010-01-01

    Phthalates are suspected of endocrine disrupting effects. We aimed to develop an analytical method for simultaneous determination of several phthalate metabolites in human urine, serum, and seminal plasma and to study correlations between levels of metabolites in these matrices. Thirteen metaboli......Phthalates are suspected of endocrine disrupting effects. We aimed to develop an analytical method for simultaneous determination of several phthalate metabolites in human urine, serum, and seminal plasma and to study correlations between levels of metabolites in these matrices. Thirteen...... metabolites were determined in samples from 60 young Danish men. Metabolites of common di-ester phthalates were detected in most urine samples. Summed di-(2-ethylhexyl) phthalate (DEHP) metabolites were excreted in urine in the highest amount (median = 91.1 ng/mL), followed by monoethyl phthalate (MEP), mono...

  20. Relaxin concentrations in serum and urine of endangered and crazy mixed-up species.

    Science.gov (United States)

    Steinetz, B; Lasano, S; de Haas van Dorsser, F; Glickman, S; Bergfelt, D; Santymire, R; Songsassen, N; Swanson, W

    2009-04-01

    The human population explosion has pushed many mammalian wildlife species to the brink of extinction. Conservationists are increasingly turning to captive breeding as a means of preserving the gene pool. We previously reported that serum immunoactive relaxin provided a reliable means of distinguishing between true and pseudopregnancy in domestic dogs, and this method has since been found to be a reliable indicator of true pregnancy in endangered Asian and African elephants and Sumatran rhinoceroses. Our canine relaxin radioimmunoassay (RIA) has now been adapted and validated to measure relaxin in the serum and urine of felids, including domestic and wild species. Moreover, a commercially available canine serum relaxin kit (Witness) Relaxin Kit; Synbiotics, San Diego, CA), has been adapted for reliable detection of relaxin in urine of some felid species. Our porcine relaxin RIA has also been utilized to investigate the role of relaxin in reproductive processes of the spotted hyena, a species in which the female fetuses are severely masculinized in utero. Indeed, this species might well now be extinct were it not for the timely secretion of relaxin to enable copulation and birth of young through the clitoris. Additional studies have suggested relaxin may be a useful marker of pregnancy in the northern fur seal and the maned wolf (the former species has been designated as "depleted" and the latter as "near threatened"). Given appropriate immunoassay reagents, relaxin determination in body fluids thus provides a powerful tool for conservationists and biologists investigating reproduction in a wide variety of endangered and exotic species.

  1. Changes of serum and urine β2-microglobulin of leukopenia in hyperthyroidism of Graves' disease before and after 131I therapy

    International Nuclear Information System (INIS)

    Lin Chen; Wang Luhua; Li Junxiong; Ouyang Liang; Guan Chuwen

    2007-01-01

    Objective: To investigate the value of 131 I therapy and the changes of the serum, urine contents of β 2 -microglobulin(β 2 -MG)in leukopenia in patients with Graves' disease before and after mi therapy. Methods: Serum and urine β 2 -MG contents (with radioimmunoassay), serum free triiodothyronine (FT 3 ) and free tetraiodothyronine (FT 4 ) lever (with chemiluminescence immunoassay) were determined before and after mi therapy. At the same time, measure blood ured nitrogen (BUN) and creatine (Cr) Results: The cure rate, improvement, invalid, hypothyroidiam and total effective rate of 131 I therpy are 76.7%, 13.3%, 3.3%, 6.7%, 96.7% respectively. The serum and urine β 2 -MG contents as well as the serum FT 3 , FT 4 levels in the 30 patients before treatment were significantly higher than those in the controls (P 3 , FT 4 levels lower than before treatment (P 2 -MG levels lower (vs before treatment, P 2 MG, FT 3 , FT 4 levels dropped to approaching normal (rs controls, P>0.05 and vs before treatments, P 3 , FT 4 level was positively correlative to the β 2 -MG (P 131 I therapy is an ideal treatment for Graves' hyperthyroidism, which have many advantages. β 2 -MG could be used as a diagnostic indicator for leukopenia in patients with Graves' disease. (authors)

  2. Combined serum and EPS-urine proteomic analysis using iTRAQ technology for discovery of potential prostate cancer biomarkers.

    Science.gov (United States)

    Zhang, Mo; Chen, Lizhu; Yuan, Zhengwei; Yang, Zeyu; Li, Yue; Shan, Liping; Yin, Bo; Fei, Xiang; Miao, Jianing; Song, Yongsheng

    2016-11-01

    Prostate cancer (PCa) is one of the most common malignant tumors and a major cause of cancer-related death for men worldwide. The aim of our study was to identify potential non-invasive serum and expressed prostatic secretion (EPS)-urine biomarkers for accurate diagnosis of PCa. Here, we performed a combined isobaric tags for relative and absolute quantification (iTRAQ) proteomic analysis to compare protein profiles using pooled serum and EPS-urine samples from 4 groups of patients: benign prostate hyperplasia (BPH), high grade prostatic intraepithelial neoplasia (HGPIN), localized PCa and metastatic PCa. The differentially expressed proteins were rigorously selected and further validated in a large and independent cohort using classical ELISA and Western blot assays. Finally, we established a multiplex biomarker panel consisting of 3 proteins (serum PF4V1, PSA, and urinary CRISP3) with an excellent diagnostic capacity to differentiate PCa from BPH [area under the receiver operating characteristic curve (AUC) of 0.941], which showed an evidently greater discriminatory ability than PSA alone (AUC, 0.757) (P<0.001). Importantly, even when PSA level was in the gray zone (4-10 ng/mL), a combination of PF4V1 and CRISP3 could achieve a relatively high diagnostic efficacy (AUC, 0.895). Furthermore, their combination also had the potential to distinguish PCa from HGPIN (AUC, 0.934). Our results demonstrated that the combined application of serum and EPS-urine biomarkers can improve the diagnosis of PCa and provide a new prospect for non-invasive PCa detection.

  3. Evaluation of the Iodine Concentration in Serum and Urine of Hypothyroid Males Using an Inexpensive and Rapid Method

    Directory of Open Access Journals (Sweden)

    Ghulam Abbas Kandhro

    2009-12-01

    Full Text Available The aim of present study was to evaluate the iodine/iodide status in biological samples (serum and urine of 172 male hypothyroid patients (HPs and their supplemental effects on thyroid hormones. For comparison purpose, non-goitrous subjects (n= 220 of same age group and socioeconomic status were also studied. A simple and rapid iodide-ion selective electrode (ISE was used to measure the concentration of iodine in microwave assisted acid digested serum and urine samples. Quality control for the methodology was established with certified samples and with those obtained by conventional wet acid digestion method on the same certified reference materials (CRMs and real samples. A linear calibration curve was obtained for a reasonable concentration range of the potassium iodide solutions. The mean concentration of iodine in the serum and urine samples of the HPs was significantly reduced as compared to control male subjects (p< 0.01. The low levels of free triiodothyronine and thyroxin were found in HPs than age matched healthy control (p< 0.005 and 0.002 respectively while high levels of thyroid stimulating hormone were observed in HPs (p< 0.008. The proposed method was relatively efficient as well as cost effective by using inexpensive equipment. It was observed that iodine in biological samples of HPs can play an important role in determining the severity of the hypothyroidism.

  4. Detection of anti-HIV-1 IgG antibodies in whole saliva by GACELISA and Western blot assays.

    Science.gov (United States)

    Matee, M I; Lyamuya, E F; Simon, E; Mbena, E C; Kagoma, C; Samaranayake, L P; Scheutz, F

    1996-05-01

    The present study, based on 158 HIV seropositives and 167 HIV seronegatives, demonstrates that saliva collected with the Omni-SAL device and tested with GACELISA (an IgG antibody capture ELISA) is an effective non-invasive alternative to serum for anti-HIV IgG antibody screening. The study also shows that a conventional serum Western blot kit can be used, with slight modifications, for confirmatory testing of saliva specimens. Collecting saliva with the Omni-SAL device had a very good acceptance rate among Tanzanian subjects, and although this diagnostic method is not yet known by the general public, 65% of the study participants preferred to give saliva instead of blood for HIV testing.

  5. An observation on positive rate of HBsAg in the urine of patients suffering from positive serum HBsAg

    Energy Technology Data Exchange (ETDEWEB)

    Peixun, Lin; Mingzheng, Zeng; Xiaoling, Chai [Wuhan Eighth Municipal Hospital, HB (China). Dept. of Laboratory

    1989-08-01

    In 1983, the Virus Research Office of the Shanxi Research Insitute of Preventive Medicine found out the granules of hepatitis B virus from the urine of patients and proved that this kind of virus can be spread through the urine. With the help of self-developed method of radio immunoelectrophoresis, our research office has purified and concentrated the urine of the patients suffering from positive serum HBsAg (hepatitis B surface antigen). Among them 25 are male, and another 25 are female. The result shows that the positive rate of HBsAg accounts for 80%. This is of important significance to the care of urine specimens, the protection of experimentalists and the development of clinical medicine.

  6. Saliva of obese patients – is it different?

    Directory of Open Access Journals (Sweden)

    Katarzyna Choromańska

    2015-01-01

    Full Text Available Obesity is a major public health concern that increases the risk of cardiovascular disease, type 2 diabetes and cancer. The incidence of obesity has increased significantly in recent years, not only in adults, but also in adolescents and children. This is evidenced by rapidly developing bariatric surgery, the most effective method of treating morbid obesity. Obesity is a multifactorial disease, and its pathogenesis is not completely understood. Numerous studies have been performed to clarify pathogenetic mechanisms, based mostly on blood and sometimes urine samples. Saliva is easily accessible and can be obtained non-invasively. Our aim was to review studies performed on saliva obtained from obese subjects in order to answer the title question.Obese people have different composition of salivary bacteria. Changes in the concentration of sialic acid, phosphorus and peroxidase activity as well as a lower flow rate of stimulated whole saliva promote dental caries and periodontal disease. Concentrations of salivary uric acid, endocannabinoids and CRP are increased in obesity and may provide a useful index of cardiometabolic risk. Assessment of fasting salivary ghrelin might facilitate choosing the best type of bariatric surgery for a specific patient. A significant decrease in salivary cortisol in women with morbid obesity also seems interesting.There is sufficient evidence to state that the saliva of obese and lean subjects is different. Saliva as an easily accessible research material seems promising, as shown by the few studies performed so far.

  7. Factors determining the passage of drugs from blood into saliva.

    Science.gov (United States)

    Stephen, K W; McCrossan, J; Mackenzie, D; Macfarlane, C B; Speirs, C F

    1980-01-01

    1. Following single oral dosing of ampicillin, cephalexin, tetracycline, erythromycin estolate, clindamycin and rifampicin to six normal volunteers, antibacterial activity was measured at 1, 3 and 6 h in serum, gingival fluid and minor gland saliva from all subjects and in parotid and submandiabular saliva from three. 2. pH values of all gingival fluid and saliva specimens were noted. 3. Partition coefficients between n-octanol and water were measured for erythromycin, clindamycin and rifampicin. Published data were used for ampicillin, cephalexin and tetracycline. 4. All antibiotics, but particularly rifampicin, were detected in gingival fluid. Only rifampicin and to a lesser degree, clindamycin were present in the other salivary constituents. 5. In studies of secretion of drugs in saliva, both the physico-chemical characteristics of the drugs and the physiological differences between individual salivary components should be considered. 6. Parotid saliva samples are likely to be of greatest value. PMID:7356893

  8. Impact of urine concentration adjustment method on associations between urine metals and estimated glomerular filtration rates (eGFR) in adolescents

    International Nuclear Information System (INIS)

    Weaver, Virginia M.; Vargas, Gonzalo García; Silbergeld, Ellen K.; Rothenberg, Stephen J.; Fadrowski, Jeffrey J.; Rubio-Andrade, Marisela; Parsons, Patrick J.; Steuerwald, Amy J.

    2014-01-01

    Positive associations between urine toxicant levels and measures of glomerular filtration rate (GFR) have been reported recently in a range of populations. The explanation for these associations, in a direction opposite that of traditional nephrotoxicity, is uncertain. Variation in associations by urine concentration adjustment approach has also been observed. Associations of urine cadmium, thallium and uranium in models of serum creatinine- and cystatin-C-based estimated GFR (eGFR) were examined using multiple linear regression in a cross-sectional study of adolescents residing near a lead smelter complex. Urine concentration adjustment approaches compared included urine creatinine, urine osmolality and no adjustment. Median age, blood lead and urine cadmium, thallium and uranium were 13.9 years, 4.0 μg/dL, 0.22, 0.27 and 0.04 g/g creatinine, respectively, in 512 adolescents. Urine cadmium and thallium were positively associated with serum creatinine-based eGFR only when urine creatinine was used to adjust for urine concentration (β coefficient=3.1 mL/min/1.73 m 2 ; 95% confidence interval=1.4, 4.8 per each doubling of urine cadmium). Weaker positive associations, also only with urine creatinine adjustment, were observed between these metals and serum cystatin-C-based eGFR and between urine uranium and serum creatinine-based eGFR. Additional research using non-creatinine-based methods of adjustment for urine concentration is necessary. - Highlights: • Positive associations between urine metals and creatinine-based eGFR are unexpected. • Optimal approach to urine concentration adjustment for urine biomarkers uncertain. • We compared urine concentration adjustment methods. • Positive associations observed only with urine creatinine adjustment. • Additional research using non-creatinine-based methods of adjustment needed

  9. Impact of urine concentration adjustment method on associations between urine metals and estimated glomerular filtration rates (eGFR) in adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, Virginia M., E-mail: vweaver@jhsph.edu [Department of Environmental Health Sciences, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Johns Hopkins University School of Medicine, Baltimore, MD (United States); Welch Center for Prevention, Epidemiology, and Clinical Research, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Vargas, Gonzalo García [Faculty of Medicine, University of Juárez of Durango State, Durango (Mexico); Secretaría de Salud del Estado de Coahuila, Coahuila, México (Mexico); Silbergeld, Ellen K. [Department of Environmental Health Sciences, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Rothenberg, Stephen J. [Instituto Nacional de Salud Publica, Centro de Investigacion en Salud Poblacional, Cuernavaca, Morelos (Mexico); Fadrowski, Jeffrey J. [Johns Hopkins University School of Medicine, Baltimore, MD (United States); Welch Center for Prevention, Epidemiology, and Clinical Research, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Rubio-Andrade, Marisela [Faculty of Medicine, University of Juárez of Durango State, Durango (Mexico); Parsons, Patrick J. [Laboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health, Albany, NY (United States); Department of Environmental Health Sciences, School of Public Health, University at Albany, Albany, NY (United States); Steuerwald, Amy J. [Laboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health, Albany, NY (United States); and others

    2014-07-15

    Positive associations between urine toxicant levels and measures of glomerular filtration rate (GFR) have been reported recently in a range of populations. The explanation for these associations, in a direction opposite that of traditional nephrotoxicity, is uncertain. Variation in associations by urine concentration adjustment approach has also been observed. Associations of urine cadmium, thallium and uranium in models of serum creatinine- and cystatin-C-based estimated GFR (eGFR) were examined using multiple linear regression in a cross-sectional study of adolescents residing near a lead smelter complex. Urine concentration adjustment approaches compared included urine creatinine, urine osmolality and no adjustment. Median age, blood lead and urine cadmium, thallium and uranium were 13.9 years, 4.0 μg/dL, 0.22, 0.27 and 0.04 g/g creatinine, respectively, in 512 adolescents. Urine cadmium and thallium were positively associated with serum creatinine-based eGFR only when urine creatinine was used to adjust for urine concentration (β coefficient=3.1 mL/min/1.73 m{sup 2}; 95% confidence interval=1.4, 4.8 per each doubling of urine cadmium). Weaker positive associations, also only with urine creatinine adjustment, were observed between these metals and serum cystatin-C-based eGFR and between urine uranium and serum creatinine-based eGFR. Additional research using non-creatinine-based methods of adjustment for urine concentration is necessary. - Highlights: • Positive associations between urine metals and creatinine-based eGFR are unexpected. • Optimal approach to urine concentration adjustment for urine biomarkers uncertain. • We compared urine concentration adjustment methods. • Positive associations observed only with urine creatinine adjustment. • Additional research using non-creatinine-based methods of adjustment needed.

  10. SELDI-TOF MS of quadruplicate urine and serum samples to evaluate changes related to storage conditions.

    Science.gov (United States)

    Traum, Avram Z; Wells, Meghan P; Aivado, Manuel; Libermann, Towia A; Ramoni, Marco F; Schachter, Asher D

    2006-03-01

    Proteomic profiling with SELDI-TOF MS has facilitated the discovery of disease-specific protein profiles. However, multicenter studies are often hindered by the logistics required for prompt deep-freezing of samples in liquid nitrogen or dry ice within the clinic setting prior to shipping. We report high concordance between MS profiles within sets of quadruplicate split urine and serum samples deep-frozen at 0, 2, 6, and 24 h after sample collection. Gage R&R results confirm that deep-freezing times are not a statistically significant source of SELDI-TOF MS variability for either blood or urine.

  11. Differential staining of Western blots of human secreted glycoproteins from serum, milk, saliva, and seminal fluid using lectins displaying diverse sugar specificities.

    Science.gov (United States)

    Gilboa-Garber, Nechama; Lerrer, Batya; Lesman-Movshovich, Efrat; Dgani, Orly

    2005-12-01

    Human milk, serum, saliva, and seminal fluid glycoproteins (gps) nourish and protect newborn and adult tissues. Their saccharides, which resemble cell membrane components, may block pathogen adhesion and infection. In the present study, they were examined by a battery of lectins from plants, animals, and bacteria, using hemagglutination inhibition and Western blot analyses. The lectins included galactophilic ones from Aplysia gonad, Erythrina corallodendron, Maclura pomifera (MPL), peanut, and Pseudomonas aeruginosa (PA-IL); fucose-binding lectins from Pseudomonas aeruginosa (PA-IIL), Ralstonia solanacearum (RSL), and Ulex europaeus (UEA-I), and mannose/glucose-binding Con A. The results demonstrated the chosen lectin efficiency for differential analysis of human secreted gps as compared to CBB staining. They unveiled the diversity of these body fluid gp glycans (those of the milk and seminal fluid being highest): the milk gps interacted most strongly with PA-IIL, followed by RSL; the saliva gps with RSL, followed by PA-IIL and MPL; the serum gps with Con A and MPL, followed by PA-IIL and RSL, and the seminal plasma gps with RSL and MPL, followed by UEA-I and PA-IIL. The potential usage of these lectins as probes for scientific, industrial, and medical purposes, and for quality control of the desired gps is clearly indicated.

  12. Per- and polyfluoroalkyl substances and fluorinated alternatives in urine and serum by on-line solid phase extraction-liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kato, Kayoko; Kalathil, Akil A; Patel, Ayesha M; Ye, Xiaoyun; Calafat, Antonia M

    2018-06-14

    Per- and polyfluoroalkyl substances (PFAS), man-made chemicals with variable length carbon chains containing the perfluoroalkyl moiety (C n F 2n+1 -), are used in many commercial applications. Since 1999-2000, several long-chain PFAS, including perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA), have been detected at trace levels in the blood of most participants of the National Health and Nutrition Examination Survey (NHANES)-representative samples of the U.S. general population-while short-chain PFAS have not. Lower detection frequencies and concentration ranges may reflect lower exposure to short-chain PFAS than to PFOS or PFOA or that, in humans, short-chain PFAS efficiently eliminate in urine. We developed on-line solid phase extraction-HPLC-isotope dilution-MS/MS methods for the quantification in 50 μL of urine or serum of 15 C 3 -C 11 PFAS (C 3 only in urine), and three fluorinated alternatives used as PFOA or PFOS replacements: GenX (ammonium salt of 2,3,3,3,-tetrafluoro-2-(1,1,2,2,3,3,3-heptafluoropropoxy)-propanoate, also known as HFPO-DA), ADONA (ammonium salt of 4,8-dioxa-3H-perfluorononanoate), and 9Cl-PF3ONS (9-chlorohexadecafluoro-3-oxanonane-1-sulfonate), main component of F53-B. Limit of detection for all analytes was 0.1 ng/mL. To validate the method, we analyzed 50 commercial urine/serum paired samples collected in 2016 from U.S. volunteers with no known exposure to the chemicals. In serum, detection frequency and concentration patterns agreed well with those from NHANES. By contrast, except for perfluorobutanoate, we did not detect long-chain or short-chain PFAS in urine. Also, we did not detect fluorinated alternatives in either urine or serum. Together, these results suggest limited exposure to both short-chain PFAS and select fluorinated alternatives in this convenience population. Copyright © 2018. Published by Elsevier Ltd.

  13. Rapid antemortem detection of CWD prions in deer saliva.

    Directory of Open Access Journals (Sweden)

    Davin M Henderson

    Full Text Available Chronic wasting disease (CWD is an efficiently transmitted prion disease of cervids, now identified in 22 United States, 2 Canadian provinces and Korea. One hallmark of CWD is the shedding of infectious prions in saliva, as demonstrated by bioassay in deer. It is also clear that the concentration of prions in saliva, blood, urine and feces is much lower than in the nervous system or lymphoid tissues. Rapid in vitro detection of CWD (and other prions in body fluids and excreta has been problematic due to the sensitivity limits of direct assays (western blotting, ELISA and the presence of inhibitors in these complex biological materials that hamper detection. Here we use real-time quaking induced conversion (RT-QuIC to demonstrate CWD prions in both diluted and prion-enriched saliva samples from asymptomatic and symptomatic white-tailed deer. CWD prions were detected in 14 of 24 (58.3% diluted saliva samples from CWD-exposed white-tailed deer, including 9 of 14 asymptomatic animals (64.2%. In addition, a phosphotungstic acid enrichment enhanced the RT-QuIC assay sensitivity, enabling detection in 19 of 24 (79.1% of the above saliva samples. Bioassay in Tg[CerPrP] mice confirmed the presence of infectious prions in 2 of 2 RT-QuIC-positive saliva samples so examined. The modified RT-QuIC analysis described represents a non-invasive, rapid ante-mortem detection of prions in complex biologic fluids, excreta, or environmental samples as well as a tool for exploring prion trafficking, peripheralization, and dissemination.

  14. Determination of psilocin, bufotenine, LSD and its metabolites in serum, plasma and urine by SPE-LC-MS/MS.

    Science.gov (United States)

    Martin, Rafaela; Schürenkamp, Jennifer; Gasse, Angela; Pfeiffer, Heidi; Köhler, Helga

    2013-05-01

    A validated method for the simultaneous determination of psilocin, bufotenine, lysergic acid diethylamide and its metabolites in serum, plasma and urine using liquid chromatography-electrospray ionization/tandem mass spectrometry was developed. During the solid-phase extraction procedure with polymeric mixed-mode cation exchange columns, the unstable analytes were protected by ascorbic acid, drying with nitrogen and exclusion of light. The limits of detection and quantitation for all analytes were low. Recovery was ≥86 % for all analytes and no significant matrix effects were observed. Interday and intraday imprecisions at different concentrations ranged from 1.1 to 8.2 % relative standard deviation, bias was within ±5.3 %. Processed samples were stable in the autosampler for at least 2 days. Furthermore, freeze/thaw and long-term stability were investigated. The method was successfully applied to authentic serum and urine samples.

  15. Radioimmunological analysis of circadian rhythms of cortisol and melatonin in saliva

    International Nuclear Information System (INIS)

    Demel, A.W.

    1990-12-01

    Since blood cortisol (F) and melatonin (MLT) display a circadian secretion pattern and since the saliva concentration of this hormones is an excellent indicator of its blood levels the measurement of salivary F and MLT may be used for examining circadian rhythmicity. In this study the relationship between salivary F and MLT was explored. For this purpose it was necessary first to establish and validate a radioimmunoassay for F in saliva: salivary F was determined by a direct radioimmunoassay using cortisol-3-(O-carboxymethyl) oximino-(2-( 125 I)iodohistamin) as tracer and cortisol-3-CMO-BSA antiserum. The parallel measurement of F levels in saliva and serum of adults gave an excellent correlation (r=0.87, p 0.00956x ). Serum F was assayed on the Abott TDX-System using a radioimmunofluorescence method. Secondly, using this assay the circadian saliva F pattern was determined as well as the pattern of salivary MLT in 9 young, healthy volunteers. For saliva MLT estimations a previously published method was applied (Schulz et al 1990). Using a computerized program (RHYTHM) written by Eve v. Cauter (1979), the hormone data of each individuum were examined for circadian rhythmicity and its acrophase (time of occurrence of the maximum of a sinusoid fitted to the data). The F acrophase occurred between 7:00 and 12:00 h (mean: 3:33 h, SD: 104.4 min). The easy stress-free non invasive nature of saliva collection makes saliva to one of the most accessible body fluids and of high value in studying the circadian system in healthy humans as well as in infants, children, pregnant women and anaemic patients. Measurements of salivary F and MLT may help to elucidate not only the circadian rhythms of these hormones under normal and pathological conditions but it may also provide insight in physiology and pathology of the circadian system in general. (author)

  16. Effects of bodybuilding and protein supplements in saliva, gingival crevicular fluid, and serum.

    Science.gov (United States)

    Aral, Kübra; Berdeli, Eynar; Aral, Cüneyt A; Berdeli, Afig; Atan, Merve

    2017-01-01

    The effects of bodybuilding and protein supplements on periodontal tissues have not yet been evaluated. The present study aimed to examine the periodontal status and interleukin (IL)-1β, apoptosis-associated speck-like protein containing C-terminal caspase-recruitment domain (ASC), and caspase 1 (CASP1) gene expression levels of body builders compared with those of controls. Twenty-five bodybuilders with gingivitis (BB-G) who used protein powder supplements were compared with 25 nonexercising males with (G) and 25 without (H) gingivitis. Saliva, gingival crevicular fluid (GCF), and serum were collected for gene expression analysis. Plaque index (PI), gingival index (GI), probing depth (PD), clinical attachment level (CAL), and bleeding on probing (BOP) were recorded. GI and BOP were higher in group BB-G and G than in group H (P 0.05). In GCF, CASP1, ASC, and IL-1β expression were upregulated in group G compared with groups BB-G and H (P Bodybuilding and supplement usage may decrease gingival inflammation by downregulating CASP1, IL-1β, and ASC.

  17. Multiple sclerosis test or the 4 humors: cerebrospinal fluid serum, tears and saliva; Esclerosis multiple test de los 4 humores: liquido cefalorraquideo, suero, lagrimas y saliva

    Energy Technology Data Exchange (ETDEWEB)

    Oehninger Gatti, C; Buzo Del Puerto, R; Chouza Antelo, C; Scotti Bianchi, C; Cibils, D; Alcantara Pelaez, J; Gomez, A; Heuguerot Oliveira, C

    1994-12-15

    4 were studied biological fluids easily accessible to the immune exploration (cerebrospinal fluid, serum, tears and saliva) in 25 patients with Multiple Sclerosis (MS) during a push clinical disease. The level of interleukin-2 receptor soluble (RsIL-2) was significantly increased by at least 3 of these 4 fluids, compared with normal controls. The sensitivity and specificity of its determination for the diagnosis of the condition was higher than other immunochemical parameters, oligoclonal distribution (OD) of immunoglobulin (Ig) light chain imbalance-and-evoked electrophysiological studies. This method is used to establish a more accurate diagnosis of Multiple Sclerosis as well as to monitor its biological activity with nuclear magnetic resonance (NMR) (Author) [Spanish] Se estudiaron 4 fluidos biologicos de facil acceso a la exploracion inmune (liquido cefalorraquideo, suero, lagrimas y saliva) en 25 pacientes con Esclerosis Multiple (EM) obtenidos durante un empuje clinico de la enfermedad. El nivel del receptor de Interleukina-2 soluble (RsIL-2) se encontro significativamente aumentado en por lo menos 3 de estos 4 fluidos, en comparacion con el de los controles normales. La sensibilidad y especificidad de su determinacion para el diagnostico de la afeccion, fue mayor que la de otros parametros inmunoquimicos - distribucion oligoclonal (DO) de inmunoglobulinas (Ig), disbalance de cadenas livianas - y estudios electrofisiologicos -potenciales evocados-. Este metodo es utilizado para establecer un diagnostico mas certero de la Esclerosis Multiple asi como tambien para monitorizar su actividad biologica junto con la resonancia magnetica nuclear (RMN)(Author)

  18. Characteristic changes of saliva and taste in burning mouth syndrome patients.

    Science.gov (United States)

    Imura, Hiroko; Shimada, Masahiko; Yamazaki, Yoko; Sugimoto, Kumiko

    2016-03-01

    Burning mouth syndrome (BMS) is characterized by chronic pain with a burning sensation of the tongue and oral mucosa and reported to be often accompanied by subjective xerostomia and dysgeusia. Since the etiology of BMS has not been elucidated, to understand the characteristics of BMS, we measured some components of saliva and taste sensitivity and compared the measured values between BMS and healthy subjects. Unstimulated saliva was collected from 15 female BMS patients and 30 healthy women. The flow rate, viscosity (spinnability) and concentration of secretory IgA (SIgA) of saliva and serum antioxidant capacity were measured. The recognition thresholds for sweet, salty, sour, bitter, and umami tastes were measured by whole-mouth method. The statistical analyses were performed using Student's t-test, and P < 0.05 was considered to be significant. In BMS group, the flow rate of saliva was significantly lower and the spinnability was significantly higher compared with healthy group. The secreted amount of SIgA per min and serum antioxidant capacity was significantly lower in the patients. The threshold for sourness in patients was significantly higher, while those for other tastes did not differ from healthy group. BMS patients showed lower salivary flow and higher salivary spinnability. These results together with decreased SIgA amount, suggest that BMS may be relevant to the deterioration of salivary condition, which could in turn affect taste function. Furthermore, the lower antioxidant capacity in patient's serum suggests that it can serve as a diagnostic tool for BMS. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Saliva with reduced calcium and phosphorous concentrations: Effect on erosion dental lesions.

    Science.gov (United States)

    Denucci, Giovanna Corrêa; Mantilla, Taís Fonseca; Amaral, Flávia Lucisano Botelho; Basting, Roberta Tarkany; França, Fabiana Mantovani Gomes; Turssi, Cecilia Pedroso

    2018-02-08

    To investigate whether saliva formulations with reduced calcium (Ca) and inorganic phosphorous (Pi) concentration would affect dental erosion caused by hydrochloric acid (HCl). Enamel and root dentine bovine slabs were embedded, polished and measured for surface Knoop microhardness (SMH). After reference areas were created, specimens were exposed to HCl solution (0.01M; pH 2; 120s) and immersed in artificial salivas (6h) containing three different Ca/Pi concentrations (n=15), which simulate serum conditions of normo-, mild- or severe hypocalcaemia. The control group was immersed in Ca/Pi-free saliva. The study protocol was carried out 2x/day for 5 days. Surface loss of enamel and root dentine was assessed using an optical profilometer and SMH was remeasured for enamel. ANOVA (pdental substrate, salivary formulations resembling serum hypocalcaemia affected surface loss due to erosion and rehardening thereof. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  20. DELTA-5-ANDROSTENEDIOL AND ITS SULFATE IN SERUM AND URINE OF NORMAL ADULTS AND PATIENTS WITH ENDOCRINE DISEASES

    NARCIS (Netherlands)

    DIKKESCHEI, LD; WILLEMSE, PHB; WOLTHERS, BG; DERUYTERBUITENHUIS, AW; NAGEL, GT

    1993-01-01

    OBJECTIVES We evaluated the role of delta-5-androstenediol (adiol) and its sulphates in health and endocrine diseases. DESIGN Serum and urine samples from healthy adult men and pre and post-menopausal women were analysed by gas chromatography-mass spectrometry to establish reference values. In

  1. Increased dietary long-chain polyunsaturated fatty acids alter serum fatty acid concentrations and lower risk of urine stone formation in cats.

    Directory of Open Access Journals (Sweden)

    Jean A Hall

    Full Text Available The lifespan of cats with non-obstructive kidney stones is shortened compared with healthy cats indicating a need to reduce stone formation and minimize chronic kidney disease. The purpose of this study was to investigate the effects of increasing dietary polyunsaturated fatty acids (PUFA on urine characteristics. Domestic-short-hair cats (n = 12; mean age 5.6 years were randomized into two groups and fed one of two dry-cat foods in a cross-over study design. For one week before study initiation, all cats consumed control food that contained 0.07% arachidonic acid (AA, but no eicosapentaenoic acid (EPA or docosahexaenoic acid (DHA. Group 1 continued eating control food for 56 days. Group 2 was fed test food for 56 days, which was control food plus fish oil and high-AA oil. Test food contained 0.17% AA, 0.09% EPA and 0.18% DHA. After 56 days, cats were fed the opposite food for another 56 days. At baseline and after each feeding period, serum was analyzed for fatty acid concentrations, and urine for specific gravity, calcium concentration, relative-super-saturation for struvite crystals, and a calcium-oxalate-titrimetric test was performed. After consuming test food, cats had increased (all P<0.001 serum concentrations of EPA (173%, DHA (61%, and AA (35%; decreased urine specific gravity (P = 0.02; decreased urine calcium concentration (P = 0.06; decreased relative-super-saturation for struvite crystals (P = 0.03; and increased resistance to oxalate crystal formation (P = 0.06 compared with cats consuming control food. Oxalate crystal formation was correlated with serum calcium concentration (r = 0.41; P<0.01. These data show benefits for reducing urine stone formation in cats by increasing dietary PUFA.

  2. Evaluation of immunologic effect of Enniatin A and quantitative determination in feces, urine and serum on treated Wistar rats.

    Science.gov (United States)

    Juan, Cristina; Manyes, Lara; Font, Guillermina; Juan-García, Ana

    2014-09-01

    Study of dietary supplementation with ENN A mycotoxin during 28 days of exposure time on Wistar rats to determinate its levels in serum, urine and feces and, to evaluate the immunologic effect in peripheral blood lymphocytes (PBL) is presented. The first method for ENN A extraction, determination and detection by LC-MS/MS in serum, urine and feces samples is reported. ENN A food dose administrated was detected in serum samples and influenced lymphocyte phenotyping. Levels in serum were founded from the second week of the experiment; reaching values of 4.76 μg/ml on the fourth week, which corresponds to 3.24 μg/ml in blood. PBL as T helper (CD4(+)) were presented in greater percentages compared to control (p ≤ 0.001), while T cytotoxic (CD8(+)) decreased significantly compared to control (p ≤ 0.001). ENN A treatment significantly increased CD4(+)/CD3(+) and CD4(+)/CD8(+) ratios but significantly decreased CD8(+)/CD3(+) ratio. CD4(+)/CD8(+) ratio was 2.94:1, indicating that PBL surface antigen expression and immune status in Wistar rats treated were impaired by the ENN A mycotoxin. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. The Cutoff Level for Urine Protein in Urine Immunofixation Electrophoresis.

    Science.gov (United States)

    Ellidag, Hamit Yasar; Curek, Gulten; Eren, Esin; Aydin, Ozgur; Yilmaz, Necat

    2015-01-01

    Immunofixation electrophoresis (IFE) maintains its importance in diagnosing monoclonal gammopathies. In particular, urine IFE detects free light chains (FLC) in urine samples even at low concentrations and offers higher sensitivity compared to serum electrophoresis and serum IFE. The aim of the present study was to determine the place and significance of quantitative urinary protein measurement before IFE in interpreting the results of subsequent IFE and to determine the most appropriate protein concentrations for the appearance of bands. The records of a total of 600 patients, who underwent screening for Bence Jones proteinuria using IFE on 24-hour urine, were retrospectively reviewed. Urine IFE was performed using Helena SAS-I and SAS-I devices. The total protein concentration in the urine was quantitatively determined by the Pyrogallol red method, and the urine albumin level was determined using the immunoturbidimetric method. These analyses were measured on an Olympus/Beckmann AU5800. The evaluation of IFE results revealed that 311 patients had normal results, 108 patients had monoclonal bands, five patients had biclonal bands, 28 had polyclonal bands, and 148 patients had various degrees of proteinuria. ROC curves were created in order to determine the most appropriate urinary protein and albumin levels to observe bands in IFE. Accordingly, urine baseline protein level (mg/dL) showed the highest AUC value (cutoff value: 19.4 mg/dL, sensitivity: 92%, specificity: 98.2%, AUC: 0.972). The present study showed that quantitative protein measurement before IFE eliminated the disadvantages associated with the IFE method and its interpretation.

  4. The correlation between LH determination in the urine (luteonosticon and HI-gonavis) and serum LH, FSH, oestradiol, progesterone testosterone and prolactin levels at midcycle

    International Nuclear Information System (INIS)

    Kemeter, P.; Woegerbauer, C.; Gring, H.; Salzer, H.; Friedrich, F.; Breitenecker, G.

    1979-01-01

    Radioimmunoassays (RIA) were carried out of serum gonadotrophins, prolactin, oestradiol, progesterone and testosterone at the time of presumed ovulation in 15 normal cycles and in 4 clomiphen-stimulated cycles of 14 women. In addition, daily measurements of LH in urine were performed using two semiquantitative methods: Luteonosticon and HI-Gonavis. Finally, the viscosity of the cervical mucus was assessed daily in order to find out the optimum time for conception. LH in serum, as well as in urine, increased significantly at midcycle and so did FSH, progesterone, testosterone, prolactin and viscosity. Lutenosticon, used in the modification of Keller and Gerber 1970 showed the first significant increase 2 days before the serum LH peak. HI-Gonavis, on the other hand, showed a significant increase only on the day of LH peak in serum. The best correlation of the 3 LH methods was found between LH in serum (RIA) and HI-Gonavis in urine. For the evaluation of the optimum time for conception in normal and clomiphen-stimulated cycles, determination of the uriany LH increase at midcycle by HI-Gonavis appears to be the most economic, both in time and expense, hormone method tested. Since only one significant increase in LH becomes apparent at midcycle by this method, the interpretation of the results is easy and additional gynaecological investigations are, thus, not absolutely necessary. (author)

  5. Evaluation of HBsAg and anti-HBc assays in saliva and dried blood spot samples according HIV status.

    Science.gov (United States)

    Flores, Geane Lopes; Cruz, Helena Medina; Potsch, Denise Vigo; May, Silvia Beatriz; Brandão-Mello, Carlos Eduardo; Pires, Marcia Maria Amendola; Pilotto, Jose Henrique; Lewis-Ximenez, Lia Laura; Lampe, Elisabeth; Villar, Livia Melo

    2017-09-01

    Influence of HIV status in HBV markers detection in saliva and dried blood spots (DBS) was not well established. This study aims to evaluate the performance of optimized commercial immunoassay for identifying HBsAg and anti-HBc in saliva and DBS according HIV status. A sum of 535 individuals grouped as HIV + , HBV + , HIV/HBV + and HIV/HBV- were recruited where 347 and 188 were included for HBsAg and anti-HBc evaluation, respectively. Serum, DBS collected in Whatman 903 paper and saliva obtained using salivette device were analyzed using EIA. Increased sample volume and ROC curve analysis for cut off determination were used for DBS and saliva testing. HBsAg detection in saliva and DBS exhibited sensitivities of 80.9% and 85.6% and specificities of 86.8% and 96.3%. Sensitivity of anti-HBc in saliva and DBS were 82.4% and 76.9% and specificities in saliva and DBS were 96.9% and 91.7%. Low sensitivities were observed for HBsAg (62%) and anti-HBc (47%) detection in saliva of HIV/HBV+ individuals. OD values were also lower for HBsAg detection in DBS and saliva of HIV/HBV+ individuals compared to their serum samples. Statistical significance was found for sensitivities in HBsAg detection between saliva and DBS demonstrating high sensitivity for DBS specimens. In conclusion, HIV status or antiretroviral treatment appears to interfere in the performance of HBsAg and anti-HBc detection in DBS and saliva samples using the adapted commercial EIA. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. The Association between Serum 25-Hydroxy Vitamin D Level and Urine Cathelicidin in Children with a Urinary Tract Infection.

    Science.gov (United States)

    Övünç Hacıhamdioğlu, Duygu; Altun, Demet; Hacıhamdioğlu, Bülent; Çekmez, Ferhat; Aydemir, Gökhan; Kul, Mustafa; Müftüoğlu, Tuba; Süleymanoğlu, Selami; Karademir, Ferhan

    2016-09-01

    Cathelicidin is an important antimicrobial peptide in the urinary tract. Cathelicidin expression is strongly stimulated by 1,25-dihydroxy vitamin D in epithelial cells, macrophages/monocytes, and neutrophils. Vitamin D and cathelicidin status in children with urinary tract infection (UTI) caused by Escherichia coli is unknown. To establish the relationship between serum vitamin D and urine cathelicidin levels in children with a UTI caused by Escherichia coli. Serum 25-hydroxy vitamin D and urine cathelicidin levels were measured in 36 patients with UTI (mean age 6.8±3.6 years, range: 0.25-12.6 years) and 38 controls (mean age 6.3±2.8 years, range: 0.42-13 years). There were no significant differences in urine cathelicidin levels between the study and control groups (p>0.05). Eight (22.2%) patients in the study group and 21 (58.3%) children in the control group were found to have sufficient vitamin D (≥20 ng/mL). Patients with sufficient vitamin D had higher urine cathelicidin levels than the controls with sufficient vitamin D (respectively 262.5±41.1 vs. 168±31.6 ng/mL, p=0.001). There were no significant differences between the patients and controls with insufficient vitamin D (p>0.05). The children with vitamin D insufficiency may not be able to increase their urine cathelicidin level during UTI caused by Escherichia coli. There is a need of prospective studies in order to prove a beneficial effect of vitamin D supplementation for the restoration of cathelicidin stimulation and consequently for prevention of UTI recurrence.

  7. Acute radiation effects on saliva composition in rats with different vitamin a levels in serum

    Energy Technology Data Exchange (ETDEWEB)

    Funegard, U; Johansson, I; Franzen, L; Ericson, T [Dept. of Cardiology, Univ. Umeaa (Sweden) Dept. of Oncology, Univ. Umeaa (Sweden)

    1991-01-01

    Irradiation of the head and neck often causes loss of salivary gland function which may lead to severe oral discomfort. The effects of a single dose of 25 Gy given to rats with different serum levels of vitamin A were studied. The salivary secretion rate as well as concentrations of protein, hexosamine, amylase and electrolytes, and the activities of two antibacterial glycoproteins were measured. At an adequates of two antibacterial glycoproteins were measured. At an adequate level of vitamin A in the diet, irradiation significantly reduced whole saliva secretion rate, and decreased the concentration of salivary sodium, calcium and hexosamine as well as the activity of a glycoprotein agglutinating a serotype c strain of S. mutans. Peroxidase, amylase and potassium were not significantly affected. The reductions seen at an adequate level of vitamin A were not reduced by supplementation of excess dietary retinol. The damage caused by irradiation was enhanced by vitamin A deficiency as seen in the reduced protein and hexosamine concentrations. (orig.).

  8. Acute radiation effects on saliva composition in rats with different vitamin a levels in serum

    International Nuclear Information System (INIS)

    Funegard, U.; Johansson, I.; Franzen, L.; Ericson, T.

    1991-01-01

    Irradiation of the head and neck often causes loss of salivary gland function which may lead to severe oral discomfort. The effects of a single dose of 25 Gy given to rats with different serum levels of vitamin A were studied. The salivary secretion rate as well as concentrations of protein, hexosamine, amylase and electrolytes, and the activities of two antibacterial glycoproteins were measured. At an adequates of two antibacterial glycoproteins were measured. At an adequate level of vitamin A in the diet, irradiation significantly reduced whole saliva secretion rate, and decreased the concentration of salivary sodium, calcium and hexosamine as well as the activity of a glycoprotein agglutinating a serotype c strain of S. mutans. Peroxidase, amylase and potassium were not significantly affected. The reductions seen at an adequate level of vitamin A were not reduced by supplementation of excess dietary retinol. The damage caused by irradiation was enhanced by vitamin A deficiency as seen in the reduced protein and hexosamine concentrations. (orig.)

  9. Toxicokinetics and correlation of carbamazepine salivary and serum concentrations in acute poisonings

    Directory of Open Access Journals (Sweden)

    Đorđević Snežana

    2012-01-01

    Full Text Available Background/Aim. Saliva is a body fluid which, like serum, can be used for determination of concentrations of certain drugs, both in pharmacotherapy as well as in acute poisonings. The aim of this study was to determine carbamazepine concentrations in both saliva and serum in acute poisoning in order to show if there is a correlation between the obtained values, as well as to monitor toxicokinetics of carbamazepine in body fluides. Methods. Saliva and serum samples were obtained from 26 patients treated with carbamazepine and 20 patients acutely poisoned by the drug immediately after their admission in the Emergency Toxicology Unit. Determination of salivary and serum carbamazepine concentrations was performed by the validated high pressure liquid chromatographyultraviolet (HPLC-UV method. Results. A significant correlation of salivary and serum carbamazepine concentrations in both therapeutic application and acute poisoning (r = 0.9481 and 0.9117, respectively was confirmed. In acute poisonings the mean ratio between salivary and serum concentrations of carbamazepine (0.43 was similar to the mean ratio after its administration in therapeutic doses (0.39, but there were high inter-individual variations in carbamazepine concentrations in the acutely poisoned patients, as a consequence of different ingested doses of the drug. In acute poisoning the halftime of carbamazepine in saliva and serum was 12.57 h and 6.76 h, respectively. Conclusion. Our results suggest a possible use of saliva as an alternative biological material for determination of carbamazepine concentrations in therapeutic application and acute poisoning as well, and a possible extrapolation of the results obtained in saliva to serum concentrations of carbamazepine.

  10. Radioimmunological analysis of circadian rhythms of cortisol and melatonin in saliva

    International Nuclear Information System (INIS)

    Demel, A.W.

    1990-12-01

    Since blood cortisol (F) and melatonin (MLT) display a circadian secretion pattern and since the saliva concentration of this hormones is an excellent indicator of its blood levels the measurement of salivary F and MLT may be user for examining circadian rhythmicity. In this study the relationship between salivary F and MLT was explored. For this purpose it was necessary first to establish and validate a radioimmunoassay for F in saliva: salivary F was determined by a direct radioimmunoassay using cortisol-3-(O-carb oxymethyl) oximino-(2-( 125 I)iodohistamin) as tracer and cortisol-3-CMO-BSA antiserum. The parallel measurement of F levels in saliva and serum of adults gave an excellent correlation (r=0.87, p 0.00956x ). Serum F was assayed on the Abott TDX-System using a radioimmunofluorescence method. Secondly, using this assay the circadian saliva F pattern was determined as well as the pattern of salivary MLT in 9 young, healthy volunteers. For saliva MLT estimations a previously published method was applied (SCHULZ et al 1990). Using a computerized program (RHYTHM) written by EVE v. CAUTER (1979), the hormone data of each individuum were examined for circadian rhythmicity and its acrophase (time of occurence of the maximum of a sinusoid fitted to the data). The F acrophase occured between 7:00 and 12:00 h (Mean: 3:33 h, SD: 104.4 min). The easy stress-free non invasive nature of saliva collection makes saliva to one of the most accessible body fluids and of high value in studying the circadian system in healthy humans as well as in infants, children, pregnant women and anaemic patients. Measurements of salivary F and MLT may help to elucidate not only the circadian rhythms of these hormones under normal and pathological conditions but it may also provide insight in physiology and pathology of the circadian system in general. (author)

  11. Urine phenobarbital drug screening: potential use for compliance assessment in neonates.

    Science.gov (United States)

    Guillet, Ronnie; Kwon, Jennifer M; Chen, Sixaio; McDermott, Michael P

    2012-02-01

    This study was done to determine if urine phenobarbital measurements provide a reliable indicator of presence of the drug in neonates. Urine was collected from neonates treated with phenobarbital for clinical indications within 4 to 6 hours of clinically indicated collection of serum phenobarbital levels. Urine samples were also collected from control neonates not treated with phenobarbital. One aliquot was assayed fresh, another frozen at -30°C and assayed 1 to 3 months later. Phenobarbital was assayed using the ONLINE TDM Roche/Hitachi automated clinical chemistry analyzer. Serum and urine concentrations were compared as were fresh and frozen urine measurements. Serum phenobarbital ranged from 5.6 to 52.7 μg/mL. Matched urine samples were 56.6 ± 12.5% of the serum level. Frozen samples were 98.3 ± 8.0% of the fresh samples. Urine phenobarbital concentrations, either fresh or frozen, can be used in neonates as a noninvasive estimate of drug levels.

  12. Simple and rapid quantification of vancomycin in serum, urine and peritoneal/pleural effusion via UHPLC-MS/MS applicable to personalized antibiotic dosing research.

    Science.gov (United States)

    Javorska, Lenka; Krcmova, Lenka Kujovska; Solich, Petr; Kaska, Milan

    2017-08-05

    Management of the therapy of life-threatening bacterial infection is extremely based on an optimal antibiotic treatment. Achieving the correct vancomycin dosage in blood and target tissues can be complicated in special situations, e.g., where large fluid sequestration and/or acute renal failure occur. A UHPLC-MS/MS method operating in electrospray (ESI) positive ion mode was applied for the determination of vancomycin in serum, urine and peritoneal/pleural effusion. Sample pretreatment was composed of dilution and simple protein precipitation where only a small volume (50μL) of serum, urine or peritoneal/pleural effusion was required. The separation of vancomycin was performed on a Meteoric Core C18 BIO column (100×4.6mm, 2.7μm) by gradient elution with 0.1% formic acid in water and acetonitrile. The total time of analysis was 4.5min. The method was found to be linear in the range of 2-60μM (or 0.5-10μM) for serum, 0.27-10μM (or 2-60μM) for peritoneal/pleural effusion and 25-300μM for urine, which was adequate for the determination of vancomycin in patient samples. The intra- and inter-day precision was below 8% RSD, and accuracy was from 89 to 104%. The UHPLC/MS-MS method offers a fast and reliable approach to determine vancomycin concentrations in three different human body fluid samples (serum, urine and peritoneal/pleural effusion) with a simple sample pretreatment that was the same for all selected specimens. This method should be applicable to large sample series in clinical (pharmacokinetic/pharmacodynamic) studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Fluoride Levels in Urine, Blood Plasma and Serum of People Living in an Endemic Fluorosis Area in the Thar Desert, Pakistan

    International Nuclear Information System (INIS)

    Rafique, T.; Shirin, K.; Ahmed, I.; Khan, M. H.; Soomro, F.

    2015-01-01

    Fluoride (F/sup -/) levels in the urine, blood plasma and serum samples of people living in a village in the Thar Desert have been analysed where fluorosis is endemic and groundwater contains fluoride as high as 9.76 mg/L. Average values of fluoride levels in these human specimens i.e. urine, blood plasma and serum have been found to be 12.98 mg/L, 0.61 mg/L and 0.75 mg/L, respectively. These values are much higher than the normal values reported from other parts of the world. It was observed that urinary fluoride levels increase with age of an individual but with an insignificant correlation (r = 0.116), however, fluoride levels in plasma and serum samples did not vary considerably with age in male and female subjects. It has been found that after the age of 50 years the urinary fluoride decreases with its concomitant increase in serum fluoride level. Since groundwater is the only available source of water for human consumption and it contains higher fluoride (av. 7.09 mg/L) than WHO limit (1.5 mg/L), therefore, it is the main cause of fluorosis in the area. (author)

  14. Parámetros inflamatorios en saliva y sangre en niños y adolescentes sanos Inflammatory parameters in saliva and blood from healthy children and adolescents

    Directory of Open Access Journals (Sweden)

    Ninoska Tahis Viera Sirit

    2011-09-01

    como fluido corporal que permita sustituir la determinación sérica de IL-1, IL-6 y sustancias reactivas al ácido tiobarbitúrico. En cuanto al TNF-a se evidenció una correlación significativa, lo cual podría plantear la posible sustitución de muestras séricas por salivales.At present times, there is interest in the use of saliva as a diagnosis, prediction and progression alternative of different pathologies in relation to the body fluids. To correlate the concentrations of IL-1, IL-6, TNF-a, substances reactive to thiobarbituric acid (RSTBA and O2- in the saliva and blood of systematically healthy children and adolescents. A cross-sectional study was performed in 23 healthy children and adolescents aged from 4 to 17 underwent to clinical tests to demonstrate the oral conditions and immunological to identify the cytokine levels and the RSTBAs by colorimetry trial. There was a significant difference in saliva samples compared to that of peripheral blood in study cytokines and RSTBAs: IL-1 (blood: 1.646 ± 0.13 pg/mL, saliva: 552.36 ± 75.7 pg/mL; IL-6 (blood: 3.506 ± 1.85 pg/mL, saliva: 26.89 ± 9.97 pg/mL: TNF-a (blood: 12.91 ± 3.05 pg/mL, saliva: 43.56 ± 6.44 pg/mL, RSTBA (blood: 9.46 ± 3.26 nmol/mL, saliva: 1.26 ± 0.03 nmol/mL. There was not a statistically significant difference among blood and saliva samples for IL-1, IL-6 and RSTBA values. As regards TNF-a it was demonstrated a significant correlation, r s= 0.78. There was not evidence of cells positive to O2 in study samples. Results of correlation analysis obtained among the saliva and serum samples not offer evidences that saliva may be used as body fluid allows substituting the serum determination of IL-1, IL-6 and RSTBA. In the case of the TNF-a, there was a significant correlation, which could to propose the possible substitution of serum samples for the salivary ones.

  15. Salivary and serum inflammatory mediators among pre-conception women with periodontal disease.

    Science.gov (United States)

    Jiang, Hong; Zhang, Yiming; Xiong, Xu; Harville, Emily W; O, Karmin; Qian, Xu

    2016-12-15

    There have been inconsistent conclusions regarding the levels of inflammatory mediators in saliva and serum among people with or without periodontal disease. Although pre-conception has been put forward as the optimal time for the periodontal treatment in order to improving pregnancy outcomes, few studies have been conducted to examine inflammatory mediators in saliva and serum among pre-conception women. Pre-conception women were recruited between January 2012 and December 2014. Women were provided with an oral health examination to detect periodontal disease. Salivary and serum samples were collected at the same of examination. Inflammatory mediators includinginterleukin-1 beta (IL-1β), IL-6, tumor necrosis factor alpha (TNF-α) and beta-glucuronidase (β-glucuronidase) were tested and analyzed among women with overall periodontal disease (n = 442) or moderate/severe periodontal disease (n = 247). Results were compared to that in women with a healthy periodontium (n = 91). Significantly increased concentrations of inflammatory mediators of IL-1β, IL-6, TNF-α and β-glucuronidase in saliva and IL-1β, β-glucuronidase and TNF-α in serum were found among pre-conception women with moderate/severe periodontal disease, compared with women without periodontal disease. Significantly increased levels were also found in all the above saliva inflammatory mediators and in serum IL-1β and TNF-α among women with overall periodontal disease. The levels of all inflammatory mediators in saliva and almost all inflammatory mediators except IL-6 in serum significantly increased with severity of periodontal disease. Periodontal disease is highly associated with the elevated levels of inflammatory mediators in saliva and some mediators in serum among pre-conception women.

  16. Detecção de imunoglobulinas IgG, IgM e IgA anti-Toxoplasma gondii no soro, líquor e saliva de pacientes com síndrome da imunodeficiência adquirida e neurotoxoplasmose Detection of anti-Toxoplasma gondii IgG, IgM and IgA immunoglobulins in the serum, cerebrospinal fluid and saliva of patients with acquired immunodeficiency syndrome and neurotoxoplasmosis

    Directory of Open Access Journals (Sweden)

    Aercio Sebastião Borges

    2004-12-01

    Full Text Available Estudamos 55 pacientes com sindrome da imunodeficiência adquirida (SIDA e neurotoxoplasmose (grupo 1; 37 pacientes com SIDA e comprometimento neurológico por outra etiologia (grupo 2 e 18 indivíduos anti-HIV negativos com manifestações neurológicas (grupo 3, pesquisando IgG, IgA e IgM anti-Toxoplasma gondii, no soro, líquor e saliva, utilizando teste ELISA, para fins diagnósticos. O valor preditivo negativo do teste para o encontro de IgG no soro foi 100% e no líquor, 92,4%. Não houve diferença entre os três grupos quanto aos anticorpos IgA neste material. Para IgA, no líquor, o teste alcançou 72,7% de especificidade (pWe studied 55 patients with acquired immunodeficiency syndrome (AIDS and neurotoxoplasmosis (group 1, 37 patients with AIDS and neurological involvement due to another etiology (group 2 and 18 anti-HIV-negative individuals with neurological manifestations, by searching for anti-T. gondii IgG, IgA and IgM immunoglobulins in serum, cerebrospinal fluid (CSFand saliva, using ELISA. The negative predictive value of the test for IgG in serum was 100% and in CSF, 92.4%. There was no difference among the three groups studied regarding IgA in serum. For IgA, in CSF the test reached 72.7% specificity (p<0.05. In saliva, only the detection of IgG was found to be correlated with a diagnosis of neurotoxoplasmosis. We emphasize that the absence of anti-T. gondii IgG antibodies in serum and CSF strongly indicates the absence of a diagnosis of neurotoxoplasmosis and that specific IgA immunoglobulins in CSF and IgG in saliva may represent two auxiliary markers for the differential diagnosis of toxoplasmic encephalitis in AIDS.

  17. Characterizing concentrations of diethylene glycol and suspected metabolites in human serum, urine, and cerebrospinal fluid samples from the Panama DEG mass poisoning.

    Science.gov (United States)

    Schier, J G; Hunt, D R; Perala, A; McMartin, K E; Bartels, M J; Lewis, L S; McGeehin, M A; Flanders, W D

    2013-12-01

    Diethylene glycol (DEG) mass poisoning is a persistent public health problem. Unfortunately, there are no human biological data on DEG and its suspected metabolites in poisoning. If present and associated with poisoning, the evidence for use of traditional therapies such as fomepizole and/or hemodialysis would be much stronger. To characterize DEG and its metabolites in stored serum, urine, and cerebrospinal fluid (CSF) specimens obtained from human DEG poisoning victims enrolled in a 2006 case-control study. In the 2006 study, biological samples from persons enrolled in a case-control study (42 cases with new-onset, unexplained AKI and 140 age-, sex-, and admission date-matched controls without AKI) were collected and shipped to the Centers for Disease Control and Prevention (CDC) in Atlanta for various analyses and were then frozen in storage. For this study, when sufficient volume of the original specimen remained, the following analytes were quantitatively measured in serum, urine, and CSF: DEG, 2-hydroxyethoxyacetic acid (HEAA), diglycolic acid, ethylene glycol, glycolic acid, and oxalic acid. Analytes were measured using low resolution GC/MS, descriptive statistics calculated and case results compared with controls when appropriate. Specimens were de-identified so previously collected demographic, exposure, and health data were not available. The Wilcoxon Rank Sum test (with exact p-values) and bivariable exact logistic regression were used in SAS v9.2 for data analysis. The following samples were analyzed: serum, 20 case, and 20 controls; urine, 11 case and 22 controls; and CSF, 11 samples from 10 cases and no controls. Diglycolic acid was detected in all case serum samples (median, 40.7 mcg/mL; range, 22.6-75.2) and no controls, and in all case urine samples (median, 28.7 mcg/mL; range, 14-118.4) and only five (23%) controls (median, urine diglycolic acid (both OR > 999; exact p sample results were excluded and two from the same case were averaged, yielding

  18. Contribution of linseed intake to urine and serum enterolignan levels in German females: a randomised controlled intervention trial.

    Science.gov (United States)

    Knust, U; Spiegelhalder, B; Strowitzki, T; Owen, R W

    2006-07-01

    Linseeds are a rich source of lignans, secondary plant substances which are suggested to possess chemopreventive effects inter alia with regard to breast cancer. In a randomised controlled trial 40 German women were informed about "5-a-day" and encouraged to increase their dietary intake of fruit and vegetables. Moreover 19 participants were randomly assigned to an intervention group supplemented with ground linseeds (20 g/d) over a 2-month period. Before and after intervention, urine and blood samples were collected after an overnight fast. Analysis was by intention-to-treat and the outcome parameters of interest were enterolignan concentrations. After linseed supplementation, enterolignan concentrations (mean) measured as their glucuronides by a newly developed high performance liquid chromatography electrospray mass spectrometry (HPLC-ESI-MS) in serum (122 nmol/l) as well as in urine (72 micromol/l) showed a significant increase (P<0.01) compared to pre-intervention values (47 nmol/l and 29 micromol/l). In the control group enterolignan levels were raised slightly but did not reach significance. Serum and urinary enterolignans of the whole collective showed a good pairwise correlation.

  19. Evaluation of a newly designed sandwich enzyme linked immunosorbent assay for the detection of hydatid antigen in serum, urine and cyst fluid for diagnosis of cystic echinococcosis.

    Science.gov (United States)

    Chaya, Dr; Parija, Subhash Chandra

    2013-07-01

    Cystic echinococcosis (CE) is a zoonotic disease of humans with variable clinical manifestations. Imaging and immunological methods are currently the mainstay of diagnosis of this disease. Although the immunological tests for detection of anti-echinococcal antibodies have several disadvantages, they are widely being used. Antigen is far more superior than antibody detection test as they can provide a specific parasitic diagnosis. A sandwich enzyme linked immunosorbent assay (ELISA) was designed using antibodies to 24 kDa urinary hydatid antigen for the detection of hydatid antigens in urine, serum and cyst fluid specimens. The performance of this novel test was compared with that of other hydatid antibody detection ELISA and enzyme immune transfer blot (EITB) using radiological and surgical confirmation as the gold standard. The antigen detection ELISA showed 100% sensitivity and specificity when tested with cyst fluid. On testing urine and serum, the antigen detection ELISA was found to be more specific than antibody detection ELISA. EITB was found to be the most sensitive and specific test. ELISA using polyclonal antibodies against 24 kDa urinary hydatid protein was moderately sensitive to detect hydatid antigen in serum and urine. Hence polyclonal antibodies to 24 kDa urinary hydatid antigen can be used as an alternative source of antibody to detect hydatid antigen in serum, urine and cyst fluid. In the present study, EITB was found to be highly specific test for detection of hydatid antibodiesin serum. 24 kDa protein was found to be specific and of diagnostic value in CE.

  20. The role of serum and urine interleukin-8 on acute pyelonephritis and subsequent renal scarring in children.

    Science.gov (United States)

    Sheu, Ji-Nan; Chen, Shan-Ming; Meng, Meng-Hsiao; Lue, Ko-Huang

    2009-10-01

    Interleukin (IL)-8 acts as a potent neutrophils chemoattractant responsible for the migration of neutrophils into the infected renal tissue to protect against invading pathogens. The aim of this study was to assess the role of IL-8 on acute-phase pyelonephritis and later renal scarring in children. A total of 124 children with a first-time febrile urinary tract infection (UTI) were studied. The diagnosis of acute pyelonephritis was confirmed by Tc-dimercaptosuccinic acid (DMSA) renal scan. Serum and urine samples were obtained from 124 children with UTI and 20 healthy children for IL-8 measurement. The 124 children were divided into acute pyelonephritis (n = 70) and lower UTI (n = 54) groups according to the results of DMSA scans. The initial serum and urine IL-8 values of children with acute pyelonephritis were significantly higher when compared with lower UTI and healthy controls (all P or =III all were independent predictors of renal scarring. Those children younger than 2 years of age with the highest IL-8 concentrations during the acute phase of pyelonephritis as well as children with reflux grades of III or greater are at a high-risk for developing renal scarring in the future.

  1. Saliva and sera IgA and IgG in Egyptian Giardia-infected children.

    Science.gov (United States)

    El-Gebaly, Naglaa Saad M; Halawa, Eman Fawzy; Moussa, Hanaa M Ezzat; Rabia, Ibrahim; Abu-Zekry, Maha

    2012-08-01

    Giardiasis is a gastrointestinal infection of wide distribution that is more prevalent in childhood. Easy and rapid diagnosis of giardiasis is essential for reduction of this infection. This cross-sectional study included 62 children in which collection of saliva, stool and serum samples was performed. An enzyme-linked immunosorbent assay (ELISA) technique was evaluated to detect IgA and IgG responses in both saliva and serum samples. Twenty-two children were positive for Giardia duodenalis infection by direct examination of faecal specimens, 20 non-infected and 20 infected with other parasites. Salivary and serum IgA and IgG responses against G. duodenalis infection were significantly higher in Giardia parasitized than non-Giardia parasitized children (p < 0.001). This concludes that specific salivary IgA may serve as a diagnostic tool and specific salivary IgG as a screening tool in monitoring the exposure of various populations to Giardia duodenalis. The advantage of salivary assays over serum immunoglobulin assay is being easy and non-invasive in sampling technique which is important especially for young children.

  2. Radioimmunological analysis of circadian rhythms of cortisol and melatonin in saliva

    International Nuclear Information System (INIS)

    Demel, A.W.

    1990-12-01

    Since blood cortisol (F) and melatonin (MTL) display a circadian secretion pattern and since the saliva concentration of these hormones is an excellent indicator of its blood levels the measurement of salivary F and MLT may be used for examining circadian rhythmicity. In these study the relationship between salivary F and MLT was explored. For this purpose it was necessary first to establish and validate a radioimmunoassay for F in saliva: salivary F was determined by a direct radioimmunoassay using cortisol-3-(O-carboxymethyl) oximino-(2- ( 125 I)iodohistamin) as tracer and cortisol-3-CMO-BSA antiserum. The parallel measurement of F levels in saliva and serum of adults gave an excellent correlation (r=0.87, p 0.00956x ). Serum F was assayed on the Abott TDX-System using a radioimmunofluorescence method. Secondly, using this assay the circadian saliva F pattern was determined as well as the pattern of salivary MLT in 9 young, healthy volunteers. For saliva MLT estimations a previously published method was applied (SCHULZ et al 1990). Using a computerized program (RHYTHM) written by EVE v. CAUTER (1979), the hormone data of each individuum were examined for circadian rhythmicity and its acrophases (time of occurrence of the maximum of a sinusoid fitted to the data). The F acrophase occured between 7:00 and 12:00 h (Mean: 8:06 h, SD: 93.8 min). The acrophase for MLT was found between 0:00 and 6:00 h (Mean: 3:33 h, SD: 104.4 min). There was a phase difference between both hormones of 3 to 7 hours (Mean: 292.5 min, SD: 74.7 min). The easy stress-free non-invasive nature of saliva collection makes saliva to one of the most accessible body fluids and of high value in studying the circadian system in healthy humans as well as in infants, children, pregnant women and anaemic patients. Measurements of salivary F and MLT may help to elucidate not only the circadian rhythms of these hormones under normal and pathological conditions but it may also provide insight in

  3. Comparing Properties (Concentration, PH and mutans streptococcus Saliva in Both Status Resting Saliva and Stimulated Saliva in Preschoolers of Kerman city

    Directory of Open Access Journals (Sweden)

    Elham Farokh-Gisour,

    2016-08-01

    Full Text Available This paper aimed to compare the characteristics (concentration, PH and mutans streptococcus saliva in both status resting saliva and stimulated saliva in preschoolers of Kerman city. In this study, 100 children aged 5 years among patients admitted to the pediatric ward of Kerman dental school and dental offices, some experts in Kerman dental school participated. Resting and stimulated saliva (after chewing oral paraffin children collected and in concentrations, PH and the amount of mutans streptococcus was measured. Mc Nemar test to compare the frequency of positive and negative cultures before and after stimulation as well as paired t-test to compare the saliva pH and concentration of not stimulated saliva and stimulated saliva in two modes was used. The significance level was set less than 0.05.The mean resting salivary osmolality of the population: 30.42 ± 87.41 and the average salivary osmolality of the total population were 79.81. Osmolality differences in saliva before and after stimulation with each other was significant (p = 0.009, paired t-test. The mean of resting saliva in the total population PH 0.45 ± 7.78 and the average PH stimulated saliva in the total population was 8.22 and the difference before and after each significant (p = 0.02, paired t-test. In mutans streptococcus in test samples in all 71 patients (71% positive test and 29 patients (29% had a negative test that number of positive cultures are equal before and after stimulation of saliva and thus the difference between the two groups (p> 0.05 was observed. In terms of comparing the properties of resting and stimulated saliva can conclude that salivary stimulated PH was significantly higher than resting saliva. While stimulated saliva osmolality was significantly less than resting saliva and the frequency of positive test mutans streptococcus in saliva before and after stimulation had no significant difference (p> 0.05. This means that test results on samples of mutans

  4. Serum and ascitic fluid serotonin levels and 5-hydroxyindoleacetic acid urine excretion in the liver of cirrhotic patients with encephalopathy.

    Science.gov (United States)

    Chojnacki, C; Walecka-Kapica, E; Stepien, A; Pawlowicz, M; Wachowska-Kelly, P; Chojnacki, J

    2013-01-01

    The excess and deficit of serotonin can be the cause of somatic and mental disorders. The aim of this study was to evaluate serotonin levels in blood and ascitic fluid as well as excretion of 5-hydroxyindoleacetic acid (5-HIAA) in urine in patients with hepatic encephalopathy (HE). The study included 75 alcoholic cirrhotic patients divided into 3 groups (HE1, HE2, HE3), 25 patients each, with grade 1, 2 and 3 of hepatic encephalopathy according to West-Haven classification. The control group (C) included 25 clinically healthy volunteers. Venous blood and ascitic fluid were collected in fasting. On the same day a 24-hour urine collection was performed. Immunoenzymatic method was used to determine the serotonin level in serum and ascitic fluid, and 5-HIAA in urine (IBL-RE-59121, RE-59131). In the control group, mean serum serotonin level (ng/ml) was 155.5 ± 38.1 and in the 3 study groups: HE1 - 175.2 ± 32.4 (NS), HE2 - 137.2 ± 28.6 (NS), HE3 - 108.3 ± 46.3 (pencephalopathy. In patients with severe hepatic encephalopathy serotonin concentration in blood is decreased which can affect some clinical manifestation of this disease.

  5. Correlation of Cyfra 21-1 levels in saliva and serum with CK19 mRNA expression in oral squamous cell carcinoma.

    Science.gov (United States)

    Malhotra, Rewa; Urs, Aadithya B; Chakravarti, Anita; Kumar, Suman; Gupta, V K; Mahajan, Bhawna

    2016-07-01

    Oral squamous cell carcinoma (OSCC) accounts for 90 % of malignant lesions of oral cavity. The study assessed the potential of Cyfra 21-1 as a tumor marker in OSCC. The study included 50 patients of OSCC to evaluate levels of Cyfra 21-1 in serum and saliva by electrochemiluminescent immunoassay (ECLIA) and CK19 messenger RNA (mRNA) expression in tissue by florescent quantitative real-time reverse transcriptase polymerase chain reaction (RT-PCR) along with healthy individuals as control. The salivary and serum Cyfra 21-1 levels in patients of OSCC were significantly higher compared to controls (p value < 0.01). There was a 2.75-fold increase in CK19 mRNA expression in OSCC cases compared to controls. A significant positive correlation was found between serum and salivary Cyfra 21-1, serum Cyfra 21-1, and CK19 mRNA expression and between salivary Cyfra 21-1 and CK19 mRNA expression. Among these, correlation between serum and salivary Cyfra 21-1 was highly significant. Salivary and serum Cyfra 21-1 showed significantly elevated levels in grade II OSCC compared to grade I histopathologically. Elevated levels of salivary Cyfra 21-1 were associated with recurrence in OSCC patients. Reverse operating curve constructed using 3 ng/ml as a cutoff for serum Cyfra 21-1 revealed the sensitivity and specificity to be 88 and 78.2 %, respectively. Using a cutoff value of 8.5 ng/ml for salivary Cyfra 21-1, the sensitivity was found to be 93.8 % and specificity 84.3 %. We advocate salivary Cyfra 21-1 as a better diagnostic marker over serum Cyfra 21-1 as well as a potential marker in the prognosis of OSCC.

  6. Assumed non-persistent environmental chemicals in human adipose tissue; matrix stability and correlation with levels measured in urine and serum

    DEFF Research Database (Denmark)

    Artacho-Cordón, F; Arrebola, J P; Nielsen, O

    2017-01-01

    The aim of this study was to (1) optimize a method for the measurement of parabens and phenols in adipose tissue, (2) evaluate the stability of chemical residues in adipose tissue samples, and (3) study correlations of these compounds in urine, serum, and adipose tissue. Samples were obtained fro...

  7. Radioimmunoassay of prostaglandins and thromboxane B2 in extracted and unextracted urine and serum using an iodinated ligand

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, D.P.; Barden, A.; Beilin, L.J.; Vandongen, R.

    1983-09-01

    A comparison of radioimmunoassay (RIA) for 6-keto PGF 1 alpha, PGE2 and TXB2 using 125I-histamine ligands and tritiated tracers showed a 7 to 10 fold increase in sensitivity for the 125I derivative, with a resultant reduction in antisera requirements by 80%. Study of the effect of purification of biological samples by organic extraction and thin layer chromatography showed that for human and rat urine, and urine from perfused rat kidneys, direct R.I.A. of unextracted samples gave substantially higher estimates of PGE2, 6-keto PGF1 alpha and TXB2 than R.I.A. purified material. Indomethacin pre-treatment reduced the levels estimated in both extracted and unextracted samples; the results indicating that the higher estimates obtained by direct assay were due to a combination of PG/TXB2 metabolites and non-specific interference. In serum from incubated human blood, estimated 6-keto PGF1 alpha and PGE2 levels were significantly higher by direct R.I.A. than after extraction, whereas TXB2 levels were similar. Thus purification procedures are unnecessary when high serum TXB2 levels are being measured by RIA with relatively specific antisera.

  8. Alterations in urine, serum and brain metabolomic profiles exhibit sexual dimorphism during malaria disease progression

    Directory of Open Access Journals (Sweden)

    Sharma Shobhona

    2010-04-01

    Full Text Available Abstract Background Metabolic changes in the host in response to Plasmodium infection play a crucial role in the pathogenesis of malaria. Alterations in metabolism of male and female mice infected with Plasmodium berghei ANKA are reported here. Methods 1H NMR spectra of urine, sera and brain extracts of these mice were analysed over disease progression using Principle Component Analysis and Orthogonal Partial Least Square Discriminant Analysis. Results Analyses of overall changes in urinary profiles during disease progression demonstrate that females show a significant early post-infection shift in metabolism as compared to males. In contrast, serum profiles of female mice remain unaltered in the early infection stages; whereas that of the male mice changed. Brain metabolite profiles do not show global changes in the early stages of infection in either sex. By the late stages urine, serum and brain profiles of both sexes are severely affected. Analyses of individual metabolites show significant increase in lactate, alanine and lysine, kynurenic acid and quinolinic acid in sera of both males and females at this stage. Early changes in female urine are marked by an increase of ureidopropionate, lowering of carnitine and transient enhancement of asparagine and dimethylglycine. Several metabolites when analysed individually in sera and brain reveal significant changes in their levels in the early phase of infection mainly in female mice. Asparagine and dimethylglycine levels decrease and quinolinic acid increases early in sera of infected females. In brain extracts of females, an early rise in levels is also observed for lactate, alanine and glycerol, kynurenic acid, ureidopropionate and 2-hydroxy-2-methylbutyrate. Conclusions These results suggest that P. berghei infection leads to impairment of glycolysis, lipid metabolism, metabolism of tryptophan and degradation of uracil. Characterization of early changes along these pathways may be crucial for

  9. Rapid determination of methadone and its major metabolite in biological fluids by gas-liquid chromatography with thermionic detection for maintenance treatment of opiate addicts.

    Science.gov (United States)

    Chikhi-Chorfi, N; Pham-Huy, C; Galons, H; Manuel, N; Lowenstein, W; Warnet, J M; Claude, J R

    1998-11-06

    A rapid gas-liquid chromatographic assay is developed for the quantification of methadone (Mtd) and its major metabolite, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), in biological fluids of opiate addicts. After alkaline extraction from samples with lidocaine hydrochloride as internal standard, Mtd and EDDP are separated on SP-2250 column at 220 degrees C and detected with a thermionic detector. The chromatographic time is about 6 min. The relative standard deviations (R.S.D.) of Mtd and EDDP standards are between 1.5 and 5.5%. Most drugs of abuse (morphine, codeine, narcotine, cocaine, benzoylecgonine, cocaethylene, dextropropoxyphene etc) are shown not to interfere with this technique. The method has been applied to study the levels of Mtd and EDDP metabolite in serum, saliva and urine of patients under maintenance treatment for opiate dependence. EDDP levels were found higher than those of Mtd in urine samples from four treated patients, but lower in serum and undetectable in saliva. However, Mtd concentrations were higher in saliva than in serum.

  10. Calcium in Urine Test

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Calcium, Serum; Calcium and Phosphates, Urine; ...

  11. Multiplex detection of pathogen biomarkers in human blood, serum, and saliva using silicon photonic microring resonators

    Science.gov (United States)

    Estrada, I. A.; Burlingame, R. W.; Wang, A. P.; Chawla, K.; Grove, T.; Wang, J.; Southern, S. O.; Iqbal, M.; Gunn, L. C.; Gleeson, M. A.

    2015-05-01

    Genalyte has developed a multiplex silicon photonic chip diagnostics platform (MaverickTM) for rapid detection of up to 32 biological analytes from a drop of sample in just 10 to 20 minutes. The chips are manufactured with waveguides adjacent to ring resonators, and probed with a continuously variable wavelength laser. A shift in the resonant wavelength as mass binds above the ring resonators is measured and is directly proportional to the amount of bound macromolecules. We present here the ability to multiplex the detection of hemorrhagic fever antigens in whole blood, serum, and saliva in a 16 minute assay. Our proof of concept testing of a multiplex antigencapture chip has the ability to detect Zaire Ebola (ZEBOV) recombinant soluble glycoprotein (rsGP), Marburg virus (MARV) Angola recombinant glycoprotein (rGP) and dengue nonstructural protein I (NS1). In parallel, detection of 2 malaria antigens has proven successful, but has yet to be incorporated into multiplex with the others. Each assay performs with sensitivity ranging from 1.6 ng/ml to 39 ng/ml depending on the antigen detected, and with minimal cross-reactivity.

  12. Determination of platinum in urine and serum after the administration of cisplatin by neutron activation analysis

    International Nuclear Information System (INIS)

    Kucera, J.; Drobnik, J.

    1982-01-01

    A simple neutron activation method is described for platinum determination in urine and serum of dogs when studying the pharmacokinetics of cisplatin, an antitumour drug. The procedure is based on the nuclear reaction 198 Pt(n,ν,ν) 199 Au, a radiochemical separation of gold, and gamma-spectrometry of the radionuclide 199 Au. Gold is separated as metal by coprecipitation with selenium after the addition of ascorbic acid in a highly acidic medium. The interference contribution of 199 Au originating from stable gold is evaluated, too. (author)

  13. Adrenal status assessed by direct radioimmunoassay of cortisol in whole saliva or parotid saliva

    International Nuclear Information System (INIS)

    Walker, R.F.; Riad-Fahmy, D.; Read, G.F.

    1978-01-01

    We describe a direct radioimmunoassay for cortisol in 10-μl volumes of parotid saliva or whole saliva. Binding proteins are absent from these fluids, as demonstrated by the excellent correlation between results for samples assayed directly and by a comparison procedure involving extraction with 1,2-dichloroethane. The direct assay is specific, precise, and had a lower limit of sensitivity of 4 pg per assay tube. Comparison of cortisol concentrations in plasma, parotid saliva, and whole saliva in persons undergoing investigations for assessing adrenal function, including stimulation with cosyntropin (Synachthen) and suppression with dexamethasone, indicated that changes in plasma cortisol concentration were accurately and immediately reflected in saliva from either the parotid-gland or whole saliva. A marked circadian rhythm has also been demonstrated for cortisol in parotid-gland saliva and whole saliva. We had to modify the 1,2-dichloroethane extraction procedure for accurate determination of cortisol in parotid saliva and whole saliva of patients undergoing treatment with metyrapone

  14. CXCL13 levels in serum but not in saliva are elevated in Asian Indian patients with primary Sjögren's syndrome.

    Science.gov (United States)

    Mandal, Santosh Kumar; Sandhya, Pulukool; Kabeerdoss, Jayakanthan; Ramya, Janardana; Mahasampath, Gowri; Danda, Debashish

    2018-05-01

    Human and animal model studies suggest CXCL13 is a potential biomarker in primary Sjögren's syndrome (pSS). CXCL13 has not been studied in Indian patients with pSS. pSS cases classified by American European Consensus Group (AECG) or American college of Rheumatology(ACR) 2012 criteria, attending rheumatology clinic between July 2014 and July 2015 were included. Hospital staff and healthy, non-blood related family members of patients constituted the control group. pSS cases underwent clinical evaluation, laboratory investigations, ESSDAI and ESSPRI scoring. Unstimulated saliva was collected by the spitting method. Salivary and serum CXCL13 were quantified by indirect ELISA. CXCL13 positivity was determined using Receiver Operator Characteristic (ROC) curve. STATA13.1 (StataCorpLP,Texas,USA) software was used for statistical analysis. In this study, 45 pSS cases and 42 healthy controls were recruited. In pSS, median levels of serum CXCL13, but not salivary CXCL13 was significantly higher as compared to the corresponding levels in healthy controls (p associated with oral symptoms (p = 0.02), ocular signs (p = 0.03) and hyperglobulinemia (p = 0.01). There was no association of salivary CXCL13 level with any of the clinical variables. While serum CXCL13 was elevated in pSS, salivary CXCL13 was not. In conclusion, serum CXCL13 positivity was found to be associated with oral symptoms, ocular signs and hyperglobulinemia in pSS.

  15. Relationship between urine albumin and endothelin in children with anaphylactoid purpura

    International Nuclear Information System (INIS)

    Duan Yongqiang; Chen Nianfa

    2009-01-01

    To study the function of urine albumin and endothelin (ET-1) in the occurrence and progress of ansphylactoid purura (HSP) and anaphylaxis purura nephritis (HSPN) in children, the serum level of ET-1 and urine albumin excretion rate in 29 children with HSP and 21 normal controls was detected by RIA and salicylic acid nephelometry respectively. The results showed that the content of urine albumin in 24 hours in HSP group has no significant difference compared with that of control group (P>0.05) , but the corresponding content in HSPN group has significant difference compared with that of control and HSP group (P<0.01). The serum ET-1 in HSP group has significant difference compared with control group (P<0.05), and the corresponding content in HSPN group has significant difference compared with control group and HSP group (P<0.01, P<0.05). The levels of urine albumin of 24 hours and serum ET-1 in HSPN group after treatment were decreased obviously compared with those before treatment (P<0.01). The content of urine albumin of 24 hours was positively correlated with serum levels of ET-1. The ET-1 participated the formation of HSP and HSPN, and was related to the occurrence and progress of urine albumin. (authors)

  16. Ethanol Induced Urine Acidification is Related with Early Acetaldehyde Concentration

    Directory of Open Access Journals (Sweden)

    Soon Kil Kwon

    2014-06-01

    Conclusion: In conclusion, urine acidification after ethanol ingestion is related with serum acetaldehyde concentration. Early elevation of acetaldhyde could induce urine acidification, but the urine pH was elevated after a few hours, that might make prolonged acidemia.

  17. Urine creatinine in treatment-naïve HIV subjects in eastern Nigeria.

    Science.gov (United States)

    Anyabolu, Ernest Ndukaife

    2016-01-01

    Human immunodeficiency virus (HIV) infection is a global healthcare problem. Some diseases and physiological states may be altered in HIV-infected individuals. Our objective was to evaluate urine creatinine and factors that influence urine creatinine in treatment-naïve HIV subjects in Nigeria. This was a cross-sectional study involving treatment-naïve HIV subjects in a tertiary hospital in Nigeria. Creatinine in spot and 24-hour urine samples and other relevant investigations were performed. Low urine creatinine or dilute urine was defined as 24-hour urine creatinine (24HUCr) creatinine as 24HUCr 300-3000mg and high urine creatinine or concentrated urine as 24HUCr>3000mg.Theassociation of low urine creatinine and high urine creatinine with potential risk factors was determined. The mean spot urine creatinine (SUCr) of the treatment-naïve HIV subjects was 137.21± 98.47(mg/dl), minimum value 13.3mg/dl, maximum value 533.3mg/dl and range of values 520.0mg/dl. The mean 24HUCr was 1507±781mg, minimum value 206mg, maximum value 4849mg and range of values 4643mg. Twenty four-hour urine creatinine3000mg in 24(6.4%) subjects. There was significant association between 24HUCr and serum low density lipoprotein cholesterol (LDL),serum high density lipoprotein cholesterol (HDL). There was high correlation between 24HUCr>3000mg and 24-hour urine osmolality (24HUOsm) (r=0.95), body mass index (BMI) (r=0.74), CD4 cells count (r=-0.71), serum HDL (r=-0.73). The prevalence of dilute urine and concentrated urine was low. Twenty-four hour urine osmolality. BMI, CD4 cells count and HDL were strong correlates of high urine creatinine. Lipid abnormalities were common in treatment-naïve HIV subjects with high urine creatinine. There is need for clinicians to routinely conduct urine creatinine and further search for abnormalities of serum lipids, weight changes, depressed immunity and anemia in HIV subjects with dilute or concentrated urine in the early stages of the infection.

  18. Salivary Creatinine Estimation as an Alternative to Serum Creatinine in Chronic Kidney Disease Patients

    OpenAIRE

    Venkatapathy, Ramesh; Govindarajan, Vasupradha; Oza, Nirima; Parameswaran, Sreejith; Pennagaram Dhanasekaran, Balamurali; Prashad, Karthikshree V.

    2014-01-01

    Context. Sampling blood for serum analysis is an invasive procedure. A noninvasive alternative would be beneficial to patients and health care professionals. Aim. To correlate serum and salivary creatinine levels and evaluate the role of saliva as a noninvasive alternative to serum for creatinine estimation in chronic kidney disease patients. Study Design. Case-control study. Methods. Blood and saliva samples were collected from 37 healthy individuals and 105 chronic kidney disease patients...

  19. Assumed non-persistent environmental chemicals in human adipose tissue; matrix stability and correlation with levels measured in urine and serum.

    Science.gov (United States)

    Artacho-Cordón, F; Arrebola, J P; Nielsen, O; Hernández, P; Skakkebaek, N E; Fernández, M F; Andersson, A M; Olea, N; Frederiksen, H

    2017-07-01

    The aim of this study was to (1) optimize a method for the measurement of parabens and phenols in adipose tissue, (2) evaluate the stability of chemical residues in adipose tissue samples, and (3) study correlations of these compounds in urine, serum, and adipose tissue. Samples were obtained from adults undergoing trauma surgery. Nine phenols and seven parabens were determined by isotope diluted TurboFlow-LC-MS/MS. The analytical method showed good accuracy and precision. Limits of detection (LOD) for parabens and phenols ranged from 0.05 to 1.83ng/g tissue. Good recovery rates were found, even when biological samples remained defrosted up to 24h. Benzophenone-3 (BP-3; range of values: 70% of adipose tissue samples, while bisphenol-A (BPA; 40% of adipose tissue samples. In general, levels were similar between adipose tissue and serum, while a correlation between adipose tissue and urine was only found for BP-3. In conclusion, adipose tissue samples in this study were found to contain environmental chemicals considered to be non-persistent, whose levels were weakly or not at all correlated with the urine burden. Therefore, adipose tissue may potentially provide additional information to that obtained from other biological matrices. Further investigations are warranted to explore whether adipose tissue might be a suitable matrix for assessment of the consequences for human health of mid/long-term exposure to these chemicals. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. The role of saliva in the process of oxidative stress – review of literature

    Directory of Open Access Journals (Sweden)

    Anna Krysińska

    2016-12-01

    Full Text Available Background: Saliva constitutes a first line of defence against free radical-mediated oxidative stress, since the process of mastication and digestion promotes lipid peroxidation. During gingival inflammation, gingival crevicular fluid flow increases the change of saliva composition with products from the inflammatory response, modulating oxidative damages in the oral cavity. Authors review the current literature concerning the reactive oxygen species, oxidants, pro-oxidants and antioxidants in saliva, and methods for assessing the antioxidant capacity of saliva. Comparison of salivary antioxidant status in male and female subjects reveales a significant gender-related difference in saliva composition. The current data demonstrate a significant enhancement of the salivary antioxidant system in juvenile idiopathic arthritis patients. Also patients with chronic renal failure, diabetes and on hemodialysis show increase oxidative stress burden in both serum and saliva. The finding of reduced oral peroxidase levels in smoking subjects may represent a contributory mechanism for initiation and progression of cigarette smoke-related oral diseases such as oral cancer. The results of recent studies indicate that the total antioxidant capacity of saliva decreased in children with HIV infection. Conclusion: Whole saliva may contain simply measured indicators of oxidative processes. This may provide a tool for the development and monitoring of new treatment strategies. A non-invasive determination of the salivary concentrations of antioxidants such as superoxide dismutase (SOD and uric acid (UR allows the evaluation of the defensive capacity of the oral mucosa. Still, there is a need for standardization of methods for saliva sampling and testing protocol.

  1. [Determination of ciprofloxacin in human serum and urine by reversed-phase HPLC].

    Science.gov (United States)

    Qin, Y; Liang, D

    1993-03-01

    A sensitive and rapid method for the determination of ciprofloxacin using enoxacin as the internal standard was reported. High-performance liquid chromatograph model 344 (Beckman, USA) with a variable wavelength UV detector and reversed-phase Ultrasphere-ODS column (5 microns, 250 x 4.6 mm) was used. Serum or urine sample preparation involved addition phosphate buffer (pH 7.5) and aqueous solution of sodium lauryl sulfate, followed by chloroform extraction. The organic layer was removed and evaporated to dryness under an air stream in a 37 degrees C water bath. The residue was dissolved in 50 microliters mobile phase and 20 microliters injected. The mobile phase of 0.02 mol/L acetate buffer (pH 3.0) -acetonitril-dimethylformamide-10% aqueous solution of tetrabutyl ammonium hydroxide (88:6.5:5:0.5) was pumped at 0.9 ml/min through the column. The detector operated at 0.01 aufs and the wavelength was set at 276 nm. The retention times for ciprofloxacin and enoxacin were 7.31 min and 5.59 min, respectively. In serum, standard curve was linear in the concentration range of 0.75 to 24 mumol/L, the detective limit was 0.2 mumol/L, extraction recovery was 69-74%, within-day CV was less than 5%, and inter-day CV was less than 6%.

  2. Tears from children with chronic hepatitis B virus (HBV) infection are infectious vehicles of HBV transmission: experimental transmission of HBV by tears, using mice with chimeric human livers.

    Science.gov (United States)

    Komatsu, Haruki; Inui, Ayano; Sogo, Tsuyoshi; Tateno, Akihiko; Shimokawa, Reiko; Fujisawa, Tomoo

    2012-08-15

    Body fluids such as saliva, urine, sweat, and tears from hepatitis B virus (HBV) carriers are potential sources of HBV transmission. Thirty-nine children and 8 adults who were chronically infected with HBV were enrolled. Real-time polymerase chain reaction was used for the quantification of HBV DNA. HBV DNA was detected in 73.7% of urine samples (14 of 19), 86.8% of saliva samples (33 of 38), 100% of tear samples (11 of 11), and 100% of sweat samples (9 of 9). Mean HBV DNA levels (±SD) in urine, saliva, tears, and sweat were 4.3 ± 1.1 log copies/mL, 5.9 ± 1.2 log copies/mL, 6.2 ± 0.7 log copies/mL, and 5.2 ± 0.6 log copies/mL, respectively. A statistically significant correlation was observed between the HBV DNA level in serum specimens and HBV DNA levels in saliva and tear specimens (r = 0.88; P Tear specimens from a child were injected intravenously into 2 human hepatocyte-transplanted chimeric mice. One week after inoculation, both chimeric mice had serum positive for HBV DNA. The levels of HBV DNA in tear specimens from young children were high. Tears were confirmed to be infectious, using chimeric mice. Strict precautions should be taken against direct contact with body fluids from HBV carriers with high-level viremia.

  3. A New Method for Noninvasive Genetic Sampling of Saliva in Ecological Research.

    Directory of Open Access Journals (Sweden)

    Diana Lobo

    Full Text Available Noninvasive samples for genetic analyses have become essential to address ecological questions. Popular noninvasive samples such as faeces contain degraded DNA which may compromise genotyping success. Saliva is an excellent alternative DNA source but scarcity of suitable collection methods makes its use anecdotal in field ecological studies. We develop a noninvasive method of collection that combines baits and porous materials able to capture saliva. We report its potential in optimal conditions, using confined dogs and collecting saliva early after deposition. DNA concentration in saliva extracts was generally high (mean 14 ng μl(-1. We correctly identified individuals in 78% of samples conservatively using ten microsatellite loci, and 90% of samples using only eight loci. Consensus genotypes closely matched reference genotypes obtained from hair DNA (99% of identification successes and 91% of failures. Mean genotyping effort needed for identification using ten loci was 2.2 replicates. Genotyping errors occurred at a very low frequency (allelic dropout: 2.3%; false alleles: 1.5%. Individual identification success increased with duration of substrate handling inside dog's mouth and the volume of saliva collected. Low identification success was associated with baits rich in DNA-oxidant polyphenols and DNA concentrations <1 ng μl(-1. The procedure performed at least as well as other noninvasive methods, and could advantageously allow detection of socially low-ranked individuals underrepresented in sources of DNA that are involved in marking behaviour (faeces or urine. Once adapted and refined, there is promise for this technique to allow potentially high rates of individual identification in ecological field studies requiring noninvasive sampling of wild vertebrates.

  4. Monodisperse, molecularly imprinted polymers for creatinine by modified precipitation polymerization and their applications to creatinine assays for human serum and urine.

    Science.gov (United States)

    Miura, Chitose; Funaya, Noriko; Matsunaga, Hisami; Haginaka, Jun

    2013-11-01

    Molecularly imprinted polymers (MIPs) for creatinine were prepared by modified precipitation polymerization using methacrylic acid as a functional monomer and divinylbenzene as a crosslinker. The prepared MIPs were monodispersed with a narrow particle size distribution. Binding experiments and Scatchard analyses revealed that two classes of binding sites, high- and low-affinity sites, were formed on the MIPs. The retention and molecular-recognition properties of the MIPs were evaluated by hydrophilic interaction chromatography using a mixture of ammonium acetate buffer and acetonitrile as a mobile phase. With an increase of acetonitrile content, the retention factor of creatinine was increased on the MIP. In addition to shape recognition, hydrophilic interactions seemed to enhance the recognition of creatinine on the MIP. The MIPs' molecular-recognition ability was specific for creatinine; the structurally related compounds such as hydantoin, 1-methylhydantoin, 2-pyrrolidone, N-hydroxysuccinimide and creatine were not recognized. Furthermore, the creatinine concentrations in human serum and urine were successfully determined by direct injection of the deproteinized serum and diluted urine samples onto the MIP. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. [Concentration of cysteine proteinase inhibitors in urine, amniotic fluid and serum from women in pregnancy complicated by EPH-gestosis].

    Science.gov (United States)

    Karmowski, A; Sobiech, K A; Kertyńska, I; Terpiłowski, L; Słowińska-Lisowska, M; Pałczyński, B; Malik, B

    2000-10-01

    Cysteine proteinase inhibitors (IPC) concentration was measured by the modified Barrett method using papaine in urine, amniotic fluid and serum obtained from the healthy labored women and from labored women in pregnancy complicated by EPH-gestosis. It was noticed the statistically significant increase in the IPC concentration in the material from the pregnant women with EPH-gestosis comparing to the women, which pregnancy had the physiologically normal course.

  6. seroprevalence of cytomegalovirus infection amongst pregnant

    African Journals Online (AJOL)

    boaz

    Cytomegalovirus (CMV) is a major public health problem throughout the world. It is the leading cause of ... Serum obtained from the blood samples were examined ... systems have been weakened by disease or drug ... fluids (e.g. saliva, urine, breast milk cervico-vaginal ... centrifuged on same day and the serum stored at -.

  7. [The effect of the light schedule on biochemical indicators in the blood, serum and urine of heifers during their estrus cycle].

    Science.gov (United States)

    Urbanová, J; Drybcák, J; Vĕzník, Z; Vojtísek, B; Alexa, P; Holcák, V; Kaláb, P; Pecka, F

    1983-10-01

    The dynamics of 38 biochemical parameters of blood, serum and urine was studied in ten heifers during their oestrous cycle in a light house (80-340 lux) and a dark small house (10-40 lux). In the light stable a significant influence (P less than 0.05) was found to be exerted on five parameters and in the dark stable nine parameters, four being influenced in the same way in both houses: haematocrit value and haemoglobin in blood and cholesterol and progesterone in serum; the relationship of progesterone content in serum to the days of oestrous cycle was particularly high in the light house. The comparison of the parameters between the groups demonstrated a significant (P less than 0.05) influence of light regime, exerted on some days of the oestrous cycle upon the levels of inorganic phosphorus, total protein and aspartate aminotransferase activity (AST) in serum and upon haematocrit, haemoglobin and ketone bodies in the blood of heifers. However, the light regime did not influence the levels of progesterone which were somewhat higher in the light house but with no statistically significant difference from the dark house. A significant difference between the groups was obtained in the levels of sodium and phosphorus in urine (P less than 0.05) between the first and tenth days of the oestrous cycle. No differences in the oestrous cycle between the heifers in the light and dark stables were recorded. Neither was the duration of heat influenced significantly; it was only less manifest in the dark stable.

  8. Urine and Serum Metabolite Profiling of Rats Fed a High-Fat Diet and the Anti-Obesity Effects of Caffeine Consumption

    Directory of Open Access Journals (Sweden)

    Hyang Yeon Kim

    2015-02-01

    Full Text Available In this study, we investigated the clinical changes induced by a high fat diet (HFD and caffeine consumption in a rat model. The mean body weight of the HFD with caffeine (HFDC-fed rat was decreased compared to that of the HFD-fed rat without caffeine. The levels of cholesterol, triglycerides (TGs, and free fatty acid, as well as the size of adipose tissue altered by HFD, were improved by caffeine consumption. To investigate the metabolites that affected the change of the clinical factors, the urine and serum of rats fed a normal diet (ND, HFD, and HFDC were analyzed using ultra performance liquid chromatography quadruple time-of-flight mass spectrometry (UPLC-Q-TOF-MS, gas chromatography (GC-TOF-MS, and linear trap quadruple mass spectrometry (LTQ-XL-MS combined with multivariate analysis. A total of 68 and 52 metabolites were found to be different in urine and serum, respectively. After being fed caffeine, some glucuronide-conjugated compounds, lysoPCs, CEs, DGs, TGs, taurine, and hippuric acid were altered compared to the HFD group. In this study, caffeine might potentially inhibit HFD-induced obesity and we suggest possible biomarker candidates using MS-based metabolite profiling.

  9. Saliva from nymph and adult females of Haemaphysalis longicornis: a proteomic study.

    Science.gov (United States)

    Tirloni, Lucas; Islam, Mohammad Saiful; Kim, Tae Kwon; Diedrich, Jolene K; Yates, John R; Pinto, Antônio F M; Mulenga, Albert; You, Myung-Jo; Da Silva Vaz, Itabajara

    2015-06-24

    Haemaphysalis longicornis is a major vector of Theileria spp., Anaplasma phagocytophilum, Babesia spp. and Coxiella burnetti in East Asian countries. All life stages of ixodid ticks have a destructive pool-feeding style in which they create a pool-feeding site by lacerating host tissue and secreting a variety of biologically active compounds that allows the tick to evade host responses, enabling the uptake of a blood meal. The identification and functional characterization of tick saliva proteins can be useful to elucidate the molecular mechanisms involved in tick development and to conceive new anti-tick control methods. H. longicornis tick saliva was collected from fully engorged nymphs and fully engorged adults induced by dopamine or pilocarpine, respectively. Saliva was digested with trypsin for LC-MS/MS sequencing and peptides were searched against tick and rabbit sequences. A total of 275 proteins were identified, of which 135 were tick and 100 were rabbit proteins. Of the tick proteins, 30 proteins were identified exclusively in fully engorged nymph saliva, 74 in fully engorged adult females, and 31 were detected in both stages. The identified tick proteins include heme/iron metabolism-related proteins, oxidation/detoxification proteins, enzymes, proteinase inhibitors, tick-specific protein families, and cytoskeletal proteins. Proteins involved in signal transduction, transport and metabolism of carbohydrate, energy, nucleotide, amino acids and lipids were also detected. Of the rabbit proteins, 13 were present in nymph saliva, 48 in adult saliva, and 30 were present in both. The host proteins include immunoglobulins, complement system proteins, antimicrobial proteins, serum albumin, peroxiredoxin, serotransferrin, apolipoprotein, hemopexin, proteinase inhibitors, and hemoglobin/red blood cells-related products. This study allows the identification of H. longicornis saliva proteins. In spontaneously detached tick saliva various proteins were identified

  10. Observations on saliva osmolality during progressive dehydration and partial rehydration.

    Science.gov (United States)

    Taylor, Nigel A S; van den Heuvel, Anne M J; Kerry, Pete; McGhee, Sheena; Peoples, Gregory E; Brown, Marc A; Patterson, Mark J

    2012-09-01

    A need exists to identify dehydrated individuals under stressful settings beyond the laboratory. A predictive index based on changes in saliva osmolality has been proposed, and its efficacy and sensitivity was appraised across mass (water) losses from 1 to 7%. Twelve euhydrated males [serum osmolality: 286.1 mOsm kg(-1) H(2)O (SD 4.3)] completed three exercise- and heat-induced dehydration trials (35.6°C, 56% relative humidity): 7% dehydration (6.15 h), 3% dehydration (with 60% fluid replacement: 2.37 h), repeat 7% dehydration (5.27 h). Expectorated saliva osmolality, measured at baseline and at each 1% mass change, was used to predict instantaneous hydration state relative to mass losses of 3 and 6%. Saliva osmolality increased linearly with dehydration, although its basal osmolality and its rate of change varied among and within subjects across trials. Receiver operating characteristic curves indicated a good predictive power for saliva osmolality when used with two, single-threshold cutoffs to differentiate between hydrated and dehydrated individuals (area under curve: 3% cutoff = 0.868, 6% cutoff = 0.831). However, when analysed using a double-threshold detection technique (3 and 6%), as might be used in a field-based monitor, <50% of the osmolality data could correctly identify individuals who exceeded 3% dehydration. Indeed, within the 3-6% dehydration range, its sensitivity was 64%, while beyond 6% dehydration, this fell to 42%. Therefore, while expectorated saliva osmolality tracked mass losses within individuals, its large intra- and inter-individual variability limited its predictive power and sensitivity, rendering its utility questionable within a universal dehydration monitor.

  11. Urine matrix metalloproteinases and their extracellular inducer EMMPRIN in children with chronic kidney disease.

    Science.gov (United States)

    Musiał, Kinga; Bargenda, Agnieszka; Zwolińska, Danuta

    2015-07-01

    Transforming growth factor (TGF)beta1 and matrix metalloproteinases (MMPs) play an essential role in CKD-related tissue remodeling. However, there are no data on urine MMPs and their extracellular inducer EMMPRIN in CKD patients. The aim of study was to assess the concentrations of MMP-2, MMP-7, MMP-9, EMMPRIN and TGFbeta1 in serum and urine of CKD children and to analyze the potential relations between those parameters. Forty-one pre-dialysis CKD children and 23 age-matched controls were enrolled in the study. The concentrations of analyzed parameters were assessed by ELISA. Serum and urine values of MMP-2, MMP-7, MMP-9, EMMPRIN and TGFbeta1 were significantly elevated in CKD patients versus controls. The MMP-2 and MMP-9 levels in urine correlated significantly with the corresponding values in serum, whereas MMP-7, EMMPRIN and TGFbeta1 urine concentrations did not. There were also significant correlations between urine values of all parameters. The increased urine levels of MMPs, EMMPRIN and TGFbeta1 indicate enhanced proteolysis and renal tissue remodeling. In the case of MMP-7, EMMPRIN and TGFbeta1 those disturbances seem independent of enhanced serum activity of the corresponding enzymes. The urine MMP-7 and EMMPRIN concentrations may serve as new independent indices of tissue remodeling and renal interstitial fibrosis in children with CKD.

  12. Assessment of sodium status in large ruminants by measuring the sodium-to-potassium ratio in muzzle secretions.

    Science.gov (United States)

    Singh, S P; Rani, D

    1999-09-01

    To develop a simple diagnostic test to assess sodium status in large ruminants on the basis of the sodium-to-potassium ratio (Na:K) and to determine its relevance. 7 buffalo heifers and 21 lactating, pregnant, and nonpregnant dairy cows and heifers. Buffalo heifers were subjected in 2 experiments to variable dietary sodium intake or sodium depletion and changes in sodium and potassium concentrations; Na:K was simultaneously monitored in various body fluids to study its value for indicating sodium status. Validity of the muzzle secretion test was assessed. Muzzle secretion and urinary Na:K and sodium concentration, but not serum electrolyte concentrations, reflected the sodium status of buffalo heifers in response to the widely variable intake of sodium (0.03 to 0.16% of dry matter [DM]). Progressive sodium depletion during an 11-day period, using saliva deprivation caused reciprocal changes in sodium and potassium concentrations in saliva and muzzle secretion, but not in urine. Decreasing urine sodium concentration was associated with decreasing urine potassium concentration. Saliva, urine, and muzzle secretion Na:K closely reflected the degree of sodium deficit. Buffaloes or dairy cows maintained on optimal sodium intake had muzzle secretion and urine Na:K > 0.30. Muzzle secretion or urine Na:K muzzle secretion Na:K, and to a large extent urine Na:K, may be used as a convenient diagnostic tool to assess sodium status in large ruminants. It has accuracy similar to that of saliva Na:K.

  13. Safety assessment of genetically modified rice expressing human serum albumin from urine metabonomics and fecal bacterial profile.

    Science.gov (United States)

    Qi, Xiaozhe; Chen, Siyuan; Sheng, Yao; Guo, Mingzhang; Liu, Yifei; He, Xiaoyun; Huang, Kunlun; Xu, Wentao

    2015-02-01

    The genetically modified (GM) rice expressing human serum albumin (HSA) is used for non-food purposes; however, its food safety assessment should be conducted due to the probability of accidental mixture with conventional food. In this research, Sprague Dawley rats were fed diets containing 50% (wt/wt) GM rice expressing HSA or non-GM rice for 90 days. Urine metabolites were detected by (1)H NMR to examine the changes of the metabolites in the dynamic process of metabolism. Fecal bacterial profiles were detected by denaturing gradient gel electrophoresis to reflect intestinal health. Additionally, short chain fatty acids and fecal enzymes were investigated. The results showed that compared with rats fed the non-GM rice, some significant differences were observed in rats fed with the GM rice; however, these changes were not significantly different from the control diet group. Additionally, the gut microbiota was associated with blood indexes and urine metabolites. In conclusion, the GM rice diet is as safe as the traditional daily diet. Furthermore, urine metabonomics and fecal bacterial profiles provide a non-invasive food safety assessment rat model for genetically modified crops that are used for non-food/feed purposes. Fecal bacterial profiles have the potential for predicting the change of blood indexes in future. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Detection of 70 kDa heat shock protein in the saliva of dairy cows.

    Science.gov (United States)

    Lamy, Elsa; Jurkovich, Viktor; Rodrigues, Lénia; Geraldo, Ana; Cachucho, Liliana; Silva, Flávio; Matos, Catarina; Capela E Silva, Fernando; Pinheiro, Cristina; Könyves, László; Bakony, Mikolt; Pereira, Alfredo

    2017-08-01

    This Research Communication describes, for the first time, the detection of HSP70 in saliva of dairy cows. Thermal stress is a major environmental stress that limits animal growth, metabolism, and productivity. The cellular response to heat stress involves the synthesis of heat shock proteins (HSPs), presumably to protect the functional stability of cells at increasing temperatures. HSP70 has been found to be present in cattle blood serum and may also be present in other secretory fluids, such as saliva, as already observed in humans. The aim of this study was to detect heat shock protein HSP70 in bovine saliva. Saliva samples were taken from higher- (n = 5) and lower milk producing (n = 5) Holstein-Friesian cows in summer and in winter for the detection of HSP70. HSP70 concentrations were assayed using the ELISA technique. Salivary HSP70 concentrations ranged from 0·524 to 12·174 ng/ml in cows. Higher salivary HSP70 concentrations were significantly associated with higher milk production and higher environmental temperature, but not with rectal temperature.

  15. Fluoride concentration in urine after silver diamine fluoride application on tooth enamel

    Science.gov (United States)

    Sari, D. L.; Bahar, A.; Gunawan, H. A.; Adiatman, M.; Rahardjo, A.; Maharani, D. A.; Toptanci, I. R.; Yavuz, I.

    2017-08-01

    Silver Diammine Fluoride (SDF), which contains fluoride, is known to inhibit tooth enamel demineralization and increase fluoride concentrations in saliva and urine. The aim of this study is to analyze the fluoride concentration in urine after application of SDF on tooth enamel. Urine from four subjects was collected prior to, 30 minutes after, and two and three hours after the application of SDF, and an ion-selective electrode was used to measure the fluoride concentrations. There was no significant difference between time 1 and time 2, time 1 and time 3, time 1 and time 4, time 2 and 3 (p > 0.05), and there was a significant difference between time 2 and time 4 as well as time 3 and time 4 (p < 0.05). There was a decrease in the concentration of fluoride ions in urine from the baseline to 30 minutes after application, and an increase from baseline to two and three hours after the application of SDF.

  16. Urine Osmolality in Treatment-naïve HIV-positive Subjects in ...

    African Journals Online (AJOL)

    2017-03-01

    Mar 1, 2017 ... a significant association between urine osmolality and body mass index (BMI), creatinine clearance, as well as serum .... approved by the Ethics Research Committee of the hospital. With the help of a questionnaire, .... SD=standard deviation, SUOsm=spot urine osmolality,. 24UOsm=24-h urine osmolality, ...

  17. Metabolic Profiling Analysis of the Alleviation Effect of Treatment with Baicalin on Cinnabar Induced Toxicity in Rats Urine and Serum

    OpenAIRE

    Guangyue Su; Guangyue Su; Gang Chen; Gang Chen; Xiao An; Haifeng Wang; Haifeng Wang; Yue-Hu Pei; Yue-Hu Pei

    2017-01-01

    Objectives: Baicalin is the main bioactive flavonoid constituent isolated from Scutellaria baicalensis Georgi. The mechanisms of protection of liver remain unclear. In this study, 1H NMR-based metabonomics approach has been used to investigate the alleviation effect of Baicalin.Method:1H NMR metabolomics analyses of urine and serum from rats, was performed to illuminate the alleviation effect of Baicalin on mineral medicine (cinnabar)-induced liver and kidney toxicity.Results: The metabolic p...

  18. Metabolic Profiling Analysis of the Alleviation Effect of Treatment with Baicalin on Cinnabar Induced Toxicity in Rats Urine and Serum

    OpenAIRE

    Su, Guangyue; Chen, Gang; An, Xiao; Wang, Haifeng; Pei, Yue-Hu

    2017-01-01

    Objectives: Baicalin is the main bioactive flavonoid constituent isolated from Scutellaria baicalensis Georgi. The mechanisms of protection of liver remain unclear. In this study, 1H NMR-based metabonomics approach has been used to investigate the alleviation effect of Baicalin. Method: 1H NMR metabolomics analyses of urine and serum from rats, was performed to illuminate the alleviation effect of Baicalin on mineral medicine (cinnabar)-induced liver and kidney toxicity. Results: The me...

  19. Kinetics of human serum amyloid A

    International Nuclear Information System (INIS)

    Rosenthal, C.J.; Martin, M.E.; Solomon, N.

    1986-01-01

    In order to better understand the pathogenetic role of serum amyloid A (SAA) we studied the kinetics of 131 I radiolabelled pure SAA, extracted from 400 ml serum of a human volunteer. 50 microCi of 131 I SAA and 15 microCi 125 I labelled sodium iodide were administered i.v. on two occasions at 6 month intervals. Serum and plasma samples were collected at 10-20 min intervals x 10, then once daily x 10; lymphocytes were separated from monocytes and granulocytes. Counts per minute of 131 I and 125 I were measured in each sample in the serum, in serum precipitates resulting after addition of a rabbit anti-SAA antibody and of TCA and in various cell subpopulations as well as in the whole urine and TCA precipitated urine from each micturition. The 131 I disappearance curves from the plasma and serum precipitates were semilogarithmically plotted; cumulative 131 I cpm in plasma, cells and urine at various intervals were determined. Body scanning was performed at 2, 16, and 48 h. The results of the two experiments were very similar. The curve of 131 I SAA in plasma TCA precipitates indicated the existence of 4 compartments likely due to uptake of 131 I SAA by some plasma proteins, circulating cells and other tissues; later release from tissues started at 6 h. The 131 I SAA half-life time in these compartments was found to be 35, 170, 255, and 550 min, respectively. Tissue binding of 131 I was also suggested by a rising of the 125 I: 131 I ratio with time and by a 26% release of 131 I in the urine at 15 h which could not account for its plasma disappearance. Scanning, except for 131 I uptake in the spleen at 2 h likely due to blood activity, showed no organ concentration. 92% of the injected 131 I was found in the urine but only 6.2% of 131 I SAA was accounted for in urine precicipitates

  20. Saliva and wound healing.

    Science.gov (United States)

    Brand, Henk S; Ligtenberg, Antoon J M; Veerman, Enno C I

    2014-01-01

    Oral wounds heal faster and with less scar formation than skin wounds. One of the key factors involved is saliva, which promotes wound healing in several ways. Saliva creates a humid environment, thus improving the survival and functioning of inflammatory cells that are crucial for wound healing. In addition, saliva contains several proteins which play a role in the different stages of wound healing. Saliva contains substantial amounts of tissue factor, which dramatically accelerates blood clotting. Subsequently, epidermal growth factor in saliva promotes the proliferation of epithelial cells. Secretory leucocyte protease inhibitor inhibits the tissue-degrading activity of enzymes like elastase and trypsin. Absence of this protease inhibitor delays oral wound healing. Salivary histatins in vitro promote wound closure by enhancing cell spreading and cell migration, but do not stimulate cell proliferation. A synthetic cyclic variant of histatin exhibits a 1,000-fold higher activity than linear histatin, which makes this cyclic variant a promising agent for the development of a new wound healing medication. Conclusively, recognition of the many roles salivary proteins play in wound healing makes saliva a promising source for the development of new drugs involved in tissue regeneration.

  1. Serum and urine analysis of the aminoterminal procollagen peptide type III by radioimmunoassay with antibody Fab fragments.

    Science.gov (United States)

    Rohde, H; Langer, I; Krieg, T; Timpl, R

    1983-09-01

    A radioimmunoassay based on antibody Fab fragments was developed for the aminoterminal peptide Col 1-3 of bovine type III procollagen. This assay does not distinguish the intact aminopropeptide Col 1-3 from its globular fragment Col 1. Parallel inhibition profiles were observed with human serum and urine allowing the simultaneous quantitative determination of intact and fragmented antigens in these samples. Most of the material has a size similar to that of fragment Col 1 indicating that the aminopropeptide is degraded under physiologic conditions. The concentration of aminopeptide in normal sera was in the range 15-63 ng/ml. Daily excretion was found to be in the range 30-110 micrograms. More than 50% of patients with alcoholic hepatitis and liver cirrhosis showed elevated serum levels of aminopropeptide by the Fab assay. Elevated concentrations were detected more frequently with an antibody radioimmunoassay which measures mainly the intact form of the aminopropeptide. It is suggested that analysis of patients material by both assays could improve their diagnostic application.

  2. Saliva and dental erosion.

    Science.gov (United States)

    Buzalaf, Marília Afonso Rabelo; Hannas, Angélicas Reis; Kato, Melissa Thiemi

    2012-01-01

    Dental erosion is a multifactorial condition. The consideration of chemical, biological and behavioral factors is fundamental for its prevention and therapy. Among the biological factors, saliva is one of the most important parameters in the protection against erosive wear. This review discusses the role of salivary factors on the development of dental erosion. A search was undertaken on MeDLINe website for papers from 1969 to 2010. The keywords used in the research were "saliva", "acquired pellicle", "salivary flow", "salivary buffering capacity" and "dental erosion". Inclusion of studies, data extraction and quality assessment were undertaken independently and in duplicate by two members of the review team. Disagreements were solved by discussion and consensus or by a third party. Several characteristics and properties of saliva play an important role in dental erosion. Salivary clearance gradually eliminates the acids through swallowing and saliva presents buffering capacity causing neutralization and buffering of dietary acids. Salivary flow allows dilution of the acids. In addition, saliva is supersaturated with respect to tooth mineral, providing calcium, phosphate and fluoride necessary for remineralization after an erosive challenge. Furthermore, many proteins present in saliva and acquired pellicle play an important role in dental erosion. Saliva is the most important biological factor affecting the progression of dental erosion. Knowledge of its components and properties involved in this protective role can drive the development of preventive measures targeting to enhance its known beneficial effects.

  3. Saliva and dental erosion

    Directory of Open Access Journals (Sweden)

    Marília Afonso Rabelo Buzalaf

    2012-10-01

    Full Text Available Dental erosion is a multifactorial condition. The consideration of chemical, biological and behavioral factors is fundamental for its prevention and therapy. Among the biological factors, saliva is one of the most important parameters in the protection against erosive wear. Objective: This review discusses the role of salivary factors on the development of dental erosion. Material and Methods: A search was undertaken on MeDLINe website for papers from 1969 to 2010. The keywords used in the research were "saliva", "acquired pellicle", "salivary flow", "salivary buffering capacity" and "dental erosion". Inclusion of studies, data extraction and quality assessment were undertaken independently and in duplicate by two members of the review team. Disagreements were solved by discussion and consensus or by a third party. Results: Several characteristics and properties of saliva play an important role in dental erosion. Salivary clearance gradually eliminates the acids through swallowing and saliva presents buffering capacity causing neutralization and buffering of dietary acids. Salivary flow allows dilution of the acids. In addition, saliva is supersaturated with respect to tooth mineral, providing calcium, phosphate and fluoride necessary for remineralization after an erosive challenge. Furthermore, many proteins present in saliva and acquired pellicle play an important role in dental erosion. Conclusions: Saliva is the most important biological factor affecting the progression of dental erosion. Knowledge of its components and properties involved in this protective role can drive the development of preventive measures targeting to enhance its known beneficial effects.

  4. Simultaneous LC-MS/MS determination of JWH-210, RCS-4, ∆(9)-tetrahydrocannabinol, and their main metabolites in pig and human serum, whole blood, and urine for comparing pharmacokinetic data.

    Science.gov (United States)

    Schaefer, Nadine; Kettner, Mattias; Laschke, Matthias W; Schlote, Julia; Peters, Benjamin; Bregel, Dietmar; Menger, Michael D; Maurer, Hans H; Ewald, Andreas H; Schmidt, Peter H

    2015-05-01

    A series of new synthetic cannabinoids (SC) has been consumed without any toxicological testing. For example, pharmacokinetic data have to be collected from forensic toxicological case work and/or animal studies. To develop a corresponding model for assessing such data, samples of controlled pig studies with two selected SC (JWH-210, RCS-4) and, as reference, ∆(9)-tetrahydrocannabinol (THC) should be analyzed as well as those of human cases. Therefore, a method for determination of JWH-210, RCS-4, THC, and their main metabolites in pig and human serum, whole blood, and urine samples is presented. Specimens were analyzed by liquid-chromatography tandem mass spectrometry and multiple-reaction monitoring with three transitions per compound. Full validation was carried out for the pig specimens and cross-validation for the human specimens concerning precision and bias. For the pig studies, the limits of detection were between 0.05 and 0.50 ng/mL in serum and whole blood and between 0.05 and 1.0 ng/mL in urine, the lower limits of quantification between 0.25 and 1.0 ng/mL in serum and 0.50 and 2.0 ng/mL in whole blood and urine, and the intra- and interday precision values lower than 15% and bias values within ±15%. The applicability was tested with samples taken from a pharmacokinetic pilot study with pigs following intravenous administration of a mixture of 200 μg/kg body mass dose each of JWH-210, RCS-4, and THC. The cross-validation data for human serum, whole blood, and urine showed that this approach should also be suitable for human specimens, e.g., of clinical or forensic cases.

  5. A competitive immunoassay for ultrasensitive detection of Hg"2"+ in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering

    International Nuclear Information System (INIS)

    She, Pei; Chu, Yanxin; Liu, Chunwei; Guo, Xun; Zhao, Kang; Li, Jianguo; Du, Haijing; Zhang, Xiang; Wang, Hong; Deng, Anping

    2016-01-01

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg"2"+. This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg"2"+ and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg"2"+. The ICT was able to directly detect Hg"2"+ without complexing due to the specific recognition of the mAb with Hg"2"+. The IC_5_0 and limit of detection (LOD) of the assay for Hg"2"+ detection were 0.12 ng mL"−"1 and 0.45 pg mL"−"1, respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg"2"+ were in range of 88.3–107.3% with the relative standard deviations (RSD) of 1.5–9.5% (n = 3). The proposed ICT was used for the detection of Hg"2"+ in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg"2"+ in environmental water samples and biological serum and urine samples. - Highlights: • The proposed ICT was able to directly detect Hg"2"+ without formation of Hg"2"+-ligand complex. • The proposed ICT exhibited high sensitivity, specificity, stability, precision and accuracy for Hg"2"+ detection. • The proposed ICT was applicable for the detection of trace amount of Hg"2"+ in water, human serum and urine samples.

  6. Increase in acrolein-conjugated immunoglobulins in saliva from patients with primary Sjögren's syndrome.

    Science.gov (United States)

    Hirose, Tadao; Saiki, Ryotaro; Uemura, Takeshi; Suzuki, Takehiro; Dohmae, Naoshi; Ito, Satoshi; Takahashi, Hoyu; Ishii, Itsuko; Toida, Toshihiko; Kashiwagi, Keiko; Igarashi, Kazuei

    2015-10-23

    We previously reported that the level of protein-conjugated acrolein (PC-Acro), a marker of cell or tissue damage, was increased in saliva from patients with primary Sjögren's syndrome (pSS), and that the level of PC-Acro was well correlated with the severity of pSS. Acrolein-conjugated immunoglobulins were measured in saliva from pSS patients. The activities of autoantibodies recognizing Sjögren's syndrome SSA (Ro) and SSB (La) proteins in saliva from pSS patients were approximately 3- to 5-fold higher than those from control subjects. We also found that autoantibody activities recognizing SSA (Ro) and SSB (La) proteins increased after acrolein treatment of saliva from control subjects. When an antibody against human serum albumin was treated with acrolein, the ability to recognize albumin was reduced but the ability to recognize other proteins was increased. Twenty-four and eleven kinds of acrolein-conjugated amino acids were found at the variable and constant regions of peptides, respectively, obtained from the immunoglobulins in saliva from pSS patients. The altered recognition patterns of immunoglobulins due to acrolein conjugation are at least partially involved in autoimmune diseases. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Androgen and androgen metabolite levels in serum and urine of East African chimpanzees (Pan troglodytes schweinfurthii): comparison of EIA and LC-MS analyses.

    Science.gov (United States)

    Preis, Anna; Mugisha, Lawrence; Hauser, Barbara; Weltring, Anja; Deschner, Tobias

    2011-12-01

    The primary male androgen testosterone (T) is often used as an endocrinological marker to investigate androgen-behaviour interactions in males. In chimpanzees and bonobos, studies investigating the relationship between T levels and dominance rank or aggressive behaviour have revealed contradictory results. The immunoassays used in these studies were originally developed for the measurement of steroids in serum. Their application to non-invasively collected samples, however, can lead to methodological problems due to cross-reacting metabolites, which might occur in urine or faeces but not in blood. The overall aim of this study, therefore, is to clarify whether a T enzyme immunoassay (EIA) is an applicable method to monitor testicular function in adult male chimpanzees. To estimate the impact of cross-reacting androgens on the used T EIA, we compared the results of an EIA measurement with a set of androgen metabolite levels measured by LC-MS. In urine from male chimpanzees, cross-reactivities appear to exist mainly with T and its exclusive metabolites, 5α-dihydrotestosterone (5α-DHT) and 5α-androstanediol (androstanediol). Both urinary and serum T levels of male chimpanzees were significantly higher than female T levels when measured with the T EIA, indicating a reliable measurement of testicular androgens and their exclusive metabolites with the used EIA. In urine from female chimpanzees, the comparison between LC-MS and T EIA results indicated a higher impact of cross-reactions with adrenal androgen metabolites. Therefore, the investigation of urinary T levels in female chimpanzees with a T EIA seems to be problematic. Overall our results show that a T EIA can be a reliable method to monitor testicular function in male chimpanzee urine and that LC-MS is a valuable tool for the validation of immunoassays. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. Measurement of recent exposure to Phlebotomus argentipes, the vector of Indian visceral Leishmaniasis, by using human antibody responses to sand fly saliva.

    Science.gov (United States)

    Clements, Meredith F; Gidwani, Kamlesh; Kumar, Rajiv; Hostomska, Jitka; Dinesh, Diwakar S; Kumar, Vijay; Das, Pradeep; Müller, Ingrid; Hamilton, Gordon; Volfova, Vera; Boelaert, Marleen; Das, Murari; Rijal, Suman; Picado, Albert; Volf, Petr; Sundar, Shyam; Davies, Clive R; Rogers, Matthew E

    2010-05-01

    Antibody (IgG) responses to the saliva of Phlebotomus argentipes were investigated using serum samples from regions of India endemic and non-endemic for visceral leishmaniasis (VL). By pre-adsorbing the sera against the saliva of the competing human-biting but non-VL vector P. papatasi, we significantly improved the specificity of a P. argentipes saliva enzyme-linked immunosorbent assay. Using this method, we observed a statistically significant correlation between antibodies to P. argenitpes saliva and the average indoor density of female sand flies. Additionally, the method was able to detect recent changes in vector exposure when sera from VL patients were assayed before, during, and after hospitalization and protected from sand fly bites under untreated bed nets. Collectively, these results highlight the utility of antibodies to P. argentipes saliva as an important tool to evaluate VL vector control programs.

  9. Analysis of Serum and Urinal Copper and Zinc in Chinese Northeast Population with the Prediabetes or Diabetes with and without Complications

    Directory of Open Access Journals (Sweden)

    Jiancheng Xu

    2013-01-01

    Full Text Available This study investigated the association of copper and zinc levels in the serum or urine of patients living in northeast China, with either prediabetes or diabetes. From January 2010 to October 2011, patients with type 1 diabetes (T1D, n=25, type 2 diabetes (T2D, n=137, impaired fasting glucose (IFG, n = 12 or impaired glucose tolerance (IGT, n=15, and age/gender matched controls (n=50 were enrolled. In the T2D group, there were 24 patients with nephropathy, 34 with retinopathy, and 50 with peripheral neuropathy. Serum copper levels were significantly higher in IFG, IGT, and T2D groups. Serum zinc level was dramatically lower, and urinary zinc level was significantly higher in both T1D and T2D subjects compared with controls. The serum zinc/copper ratio was significantly lower in all the patients with IFG, ITG, T1D, and T2D. The serum copper level was positively associated with HbA1c in T2D subjects. Simvastatin treatment in T2D patients had no significant effect on serum and urinary copper and zinc. These results suggest the need for further studies of the potential impact of the imbalanced serum copper and zinc levels on metabolic syndrome, diabetes, and diabetic complications.

  10. Urine colorimetry for therapeutic drug monitoring of pyrazinamide during tuberculosis treatment.

    Science.gov (United States)

    Zentner, Isaac; Modongo, Chawangwa; Zetola, Nicola M; Pasipanodya, Jotam G; Srivastava, Shashikant; Heysell, Scott K; Mpagama, Stellah; Schlect, Hans P; Gumbo, Tawanda; Bisson, Gregory P; Vinnard, Christopher

    2018-03-01

    Pyrazinamide is a key drug in the first-line treatment regimen for tuberculosis, with a potent sterilizing effect. Although low pyrazinamide peak serum concentrations (C max ) are associated with poor treatment outcomes, many resource-constrained settings do not have sufficient laboratory capacity to support therapeutic drug monitoring (TDM). The objective of this study was to determine whether a colorimetric test of urine can identify tuberculosis patients with adequate pyrazinamide exposures, as defined by serum C max above a target threshold. In the derivation study of healthy volunteers, three dose sizes of pyrazinamide were evaluated, and intensive pharmacokinetic blood sampling was performed over an 8-h period, with a timed urine void at 4h post-dosing. Pyrazinamide in urine was isolated by spin column centrifugation with an exchange resin, followed by colorimetric analysis; the absorbance peak at 495nm was measured. The urine assay was then evaluated in a study of 39 HIV/tuberculosis patients in Botswana enrolled in an intensive pharmacokinetic study. Receiver operating characteristics (ROC) curves were used to measure diagnostic accuracy. The guideline-recommended pyrazinamide serum C max target of 35mg/l was evaluated in the primary analysis; this target was found to be predictive of favorable outcomes in a clinical study. Following this, a higher serum C max target of 58mg/l was evaluated in the secondary analysis. At the optimal cut-off identified in the derivation sample, the urine colorimetric assay was 97% sensitive and 50% specific to identify 35 of 39 HIV/tuberculosis patients with pharmacokinetic target attainment, with an area under the ROC curve of 0.81 (95% confidence interval 0.60-0.97). Diagnostic accuracy was lower at the 58mg/l serum C max target, with an area under the ROC curve of 0.68 (95% confidence interval 0.48-0.84). Men were less likely than women to attain either serum pharmacokinetic target. The urine colorimetric assay was

  11. A comparison of the adsorption of saliva proteins and some typical proteins onto the surface of hydroxyapatite

    NARCIS (Netherlands)

    Kawasaki, K; Kambara, M; Matsumura, H; Norde, W

    2003-01-01

    Adsorption of protein from saliva on hydroxyapatite was compared with adsorption of several typical proteins with different electric charges, i.e. lysozyme, human serum albumin, beta-lactoglobulin and ovalbumin. Adsorbed amounts of these proteins were determined and electrophoretic mobilities of

  12. A comparison of the adsorption of saliva proteins and some typical proteins onto the surface of hydroxyapatite

    NARCIS (Netherlands)

    Kawasaki, K.; Kambara, M.; Matsumura, H.; Norde, W.

    2003-01-01

    Adsorption of protein from saliva on hydroxyapatite was compared with adsorption of several typical proteins with different electric charges, i.e. lysozyme, human serum albumin, @b-lactoglobulin and ovalbumin. Adsorbed amounts of these proteins were determined and electrophoretic mobilities of

  13. The development and applications of polyclonal and monoclonal antibodies for the detection of illicit drugs in saliva samples

    OpenAIRE

    Fanning, Lorna M.

    2002-01-01

    Anti-tetrahydrocannabinol (THC), anti-cocaine and anti-morphine polyclonal antibodies were produced. These antibodies were successfully applied to an ELISA format for the detection of THC, cocaine, and morphine in saliva samples. Monoclonal antibodies against amphetamine and its derivatives were produced using two different conjugates, amphetamine-bovine serum albumin and methamphetaminebovine serum albumin. Two successful clones were produced, and the antibodies were applied to an ELISA ...

  14. Formation of an adduct by clenbuterol, a beta-adrenoceptor agonist drug, and serum albumin in human saliva at the acidic pH of the stomach: evidence for an aryl radical-based process.

    Science.gov (United States)

    Pietraforte, D; Brambilla, G; Camerini, S; Scorza, G; Peri, L; Loizzo, A; Crescenzi, M; Minetti, M

    2008-07-15

    Clenbuterol (CLB) is an antiasthmatic drug used also illegally as a lean muscle mass enhancer in both humans and animals. CLB and amine-related drugs in general are nitrosatable, thus raising concerns regarding possible genotoxic/carcinogenic activity. Oral administration of CLB raises the issue of its possible transformation by salivary nitrite at the acidic pH of gastric juice. In acidic human saliva CLB was rapidly transformed to the CLB arenediazonium ion. This suggests a reaction of CLB with salivary nitrite, as confirmed in aerobic HNO(2) solution by a drastic decrease in nitric oxide, nitrite, and nitrate. In human saliva, both glutathione and ascorbic acid were able to inhibit CLB arenediazonium formation and to react with preformed CLB arenediazonium. The effect of ascorbic acid is particularly pertinent because this vitamin is actively concentrated within the gastric juice. EPR spin trapping experiments showed that preformed CLB arenediazonium ion was reduced to the aryl radical by ascorbic acid, glutathione, and serum albumin, the major protein of saliva. As demonstrated by anti-CLB antibodies and MS, the CLB-albumin interaction leads to the formation of a covalent drug-protein adduct, with a preference for Tyr-rich regions. This study highlights the possible hazards associated with the use/abuse of this drug.

  15. The soluble receptor for vitamin B12 uptake (sCD320) increases during pregnancy and occurs in higher concentration in urine than in serum

    DEFF Research Database (Denmark)

    Abuyaman, Omar; Andreasen, Birgitte H; Kronborg, Camilla

    2013-01-01

    BACKGROUND: Cellular uptake of vitamin B12 (B12) demands binding of the vitamin to transcobalamin (TC) and recognition of TC-B12 (holoTC) by the receptor CD320, a receptor expressed in high quantities on human placenta. We have identified a soluble form of CD320 (sCD320) in serum and here we...... gestational weeks 17-41. sCD320, holoTC, total TC and complex formation between holoTC and sCD320 were measured by in-house ELISA methods, while creatinine was measured on the automatic platform Cobas 6000. Size exclusion chromatography was performed on a Superdex 200 column. RESULTS: Median (range) of serum...... was around two fold higher than in serum. Urinary sCD320/creatinine ratio correlated with serum sCD320 and reached a peak median level of 53 (30-101) pmol/mmol creatinine (week 35). sCD320 present in serum and urine showed the same elution pattern upon size exclusion chromatography. CONCLUSION: We report...

  16. Serum and urine trace metals in ketosis

    Energy Technology Data Exchange (ETDEWEB)

    Burch, R.E.; Hiner, C.; Sullivan, J.F.

    1974-01-01

    Three groups of male rats were housed in metabolic cages. The control group was fed ad libitum, a second group was fasted and diabetes was induced in the third group by the subcutaneous injection of alloxan. After 48 hours all animals were bled and livers, which were quick-frozen in situ, were obtained. Fasted and diabetic animals were ketotic as manifested by lowering urinary pH and elevated urinary and blood acetoacetate and ..beta..-hydroxybutyrate. Blood and hepatic content of acetate was elevated in diabetic versus control rats. Blood and hepatic content of acetate was not increased in fasted animals. In fasted rats total urinary Zn and Cu were decreased and Mg and Ca did not differ significantly from control values. In diabetic rats total urinary excretion of Mg was increased whereas urinary Zn, Cu and Ca levels did not differ significantly from control values. In fasted animals only serum Zn was diminished. In diabetic rats serum Cu and Ca were decreased and serum Mg was increased while serum Zn was unchanged. Thus, the ketosis of fasting differs from the ketosis of diabetes in several of its metabolic manifestations. 11 references, 9 figures.

  17. A Simple and High-Throughput Analysis of Amatoxins and Phallotoxins in Human Plasma, Serum and Urine Using UPLC-MS/MS Combined with PRiME HLB μElution Platform

    Directory of Open Access Journals (Sweden)

    Shuo Zhang

    2016-05-01

    Full Text Available Amatoxins and phallotoxins are toxic cyclopeptides found in the genus Amanita and are among the predominant causes of fatal food poisoning in China. In the treatment of Amanita mushroom poisoning, an early and definite diagnosis is necessary for a successful outcome, which has prompted the development of protocols for the fast and confirmatory determination of amatoxins and phallotoxins in human biological fluids. For this purpose, a simple, rapid and sensitive multiresidue UPLC-MS/MS method for the simultaneous determination of α-amanitin, β-amanitin, γ-amanitin, phalloidin (PHD and phallacidin (PCD in human plasma, serum and urine was developed and validated. The diluted plasma, serum and urine samples were directly purified with a novel PRiME technique on a 96-well μElution plate platform, which allowed high-throughput sample processing and low reagent consumption. After purification, a UPLC-MS/MS analysis was performed using positive electrospray ionization (ESI+ in multiple reaction monitoring (MRM mode. This method fulfilled the requirements of a validation test, with good results for the limit of detection (LOD, lower limit of quantification (LLOQ, accuracy, intra- and inter-assay precision, recovery and matrix effects. All of the analytes were confirmed and quantified in authentic plasma, serum and urine samples obtained from cases of poisoning using this method. Using the PRiME μElution technique for quantification reduces labor and time costs and represents a suitable method for routine toxicological and clinical emergency analysis.

  18. A device for the collection of submandibular saliva.

    Science.gov (United States)

    Hanning, Sara; Motoi, Lidia; Medlicott, Natalie; Swindells, Stephen

    2012-03-01

    The objective of this study was to describe the construction of a non-invasive device for the collection of submandibular saliva. Preliminary tests were carried out on saliva collected from a single donor in order to determine whether the rheological properties of submandibular saliva collected using the device were comparable to whole saliva collected using the expectoration (or 'spit') method. The device collected a lower quantity of saliva than that collected using the expectoration method. Stimulated saliva collected using the device had a pH close to that of unstimulated saliva because the sealed collection unit in the device minimised contamination. Saliva exhibited shear-thinning behaviour regardless of the method of collection, although that collected using the device was more viscous. The viscoelasticity of saliva collected using the two methods was different, probably as a result of differences in composition. This difference was greater with stimulated saliva. Despite the discrepancies between whole saliva and submandibular saliva, the device provides a non-invasive method for the collection of high-quality saliva over extended periods.

  19. Parabens in urine, serum and seminal plasma from healthy Danish men determined by liquid chromatography-tandem mass spectrometry (LC-MS/MS)

    DEFF Research Database (Denmark)

    Frederiksen, Hanne; Jørgensen, Niels; Andersson, Anna-Maria

    2011-01-01

    Parabens are used as anti-microbial preservatives in a range of consumer products, especially in cosmetics. In vitro and animal studies have shown weak estrogenic and other endocrine disrupting effects of parabens, including reduced testosterone levels in exposed male rats. The knowledge of paraben...... exposure, distribution and excretion in humans is limited. In this study we determined the concentration of five parabens; methyl-, ethyl-, n-propyl-, n-butyl- and benzylparaben in urine, serum and seminal plasma samples from 60 healthy Danish men. To conduct the study a sensitive and specific method using...... LC-MS/MS for simultaneous determination of the five parabens was developed for all three different matrices. Highest concentrations of the parabens were found in urine, wherein methyl-, ethyl-, n-propyl- and n-butyl parabens were measurable in 98%, 80%, 98% and 83% of the men, respectively. Benzyl...

  20. Oestrogens in saliva

    International Nuclear Information System (INIS)

    Rothschild, R.S.; Levine, L.S.; Hattingh, J.

    1981-01-01

    Matched plasma and saliva samples were obtained from a non-pregnant and pregnant group (last trimester) of female caucasians. Using a sensitive radioimmunoassay, 17β-oestradiol was measured, and the gingival index system of Loe (1967) was used to assess the gingival condition of each patient. The results showed that 17β-oestradiol could be measured in saliva but that the levels were extremely low and a very sensitive immunoassay was necessary. In the pregnant group, saliva represented 3 per cent of the plasma level. This was not the case in the non-pregnant group, probably because of the constantly changing free: bound plasma ratio. The results are discussed in relation to the fact that oestrogens are known to bind to the oral epithelium [af

  1. Optimal preprocessing of serum and urine metabolomic data fusion for staging prostate cancer through design of experiment

    International Nuclear Information System (INIS)

    Zheng, Hong; Cai, Aimin; Zhou, Qi; Xu, Pengtao; Zhao, Liangcai; Li, Chen; Dong, Baijun; Gao, Hongchang

    2017-01-01

    Accurate classification of cancer stages will achieve precision treatment for cancer. Metabolomics presents biological phenotypes at the metabolite level and holds a great potential for cancer classification. Since metabolomic data can be obtained from different samples or analytical techniques, data fusion has been applied to improve classification accuracy. Data preprocessing is an essential step during metabolomic data analysis. Therefore, we developed an innovative optimization method to select a proper data preprocessing strategy for metabolomic data fusion using a design of experiment approach for improving the classification of prostate cancer (PCa) stages. In this study, urine and serum samples were collected from participants at five phases of PCa and analyzed using a 1 H NMR-based metabolomic approach. Partial least squares-discriminant analysis (PLS-DA) was used as a classification model and its performance was assessed by goodness of fit (R 2 ) and predictive ability (Q 2 ). Results show that data preprocessing significantly affect classification performance and depends on data properties. Using the fused metabolomic data from urine and serum, PLS-DA model with the optimal data preprocessing (R 2  = 0.729, Q 2  = 0.504, P < 0.0001) can effectively improve model performance and achieve a better classification result for PCa stages as compared with that without data preprocessing (R 2  = 0.139, Q 2  = 0.006, P = 0.450). Therefore, we propose that metabolomic data fusion integrated with an optimal data preprocessing strategy can significantly improve the classification of cancer stages for precision treatment. - Highlights: • NMR metabolomic analysis of body fluids can be used for staging prostate cancer. • Data preprocessing is an essential step for metabolomic analysis. • Data fusion improves information recovery for cancer classification. • Design of experiment achieves optimal preprocessing of metabolomic data fusion.

  2. GC-MS determination of creatinine in human biological fluids as pentafluorobenzyl derivative in clinical studies and biomonitoring: Inter-laboratory comparison in urine with Jaffé, HPLC and enzymatic assays.

    Science.gov (United States)

    Tsikas, Dimitrios; Wolf, Alexander; Mitschke, Anja; Gutzki, Frank-Mathias; Will, Wolfgang; Bader, Michael

    2010-10-01

    In consideration of its relatively constant urinary excretion rate, creatinine in urine is a useful biochemical parameter to correct the urinary excretion rate of endogenous and exogenous biomolecules. Assays based on the reaction of creatinine and picric acid first reported by Jaffé in 1886 still belong to the most frequently used laboratory approaches for creatinine measurement in urine. Further analytical methods for creatinine include HPLC-UV, GC-MS, and LC-MS and LC-MS/MS approaches. In the present article we report on the development, validation and biomedical application of a new GC-MS method for the reliable quantitative determination of creatinine in human urine, plasma and serum. This method is based on the derivatization of creatinine (d(0)-Crea) and the internal standard [methyl-trideutero]creatinine (d(3)-Crea) with pentafluorobenzyl (PFB) bromide in the biological sample directly or after dilution with phosphate buffered saline, extraction of the reaction products with toluene and quantification in 1-μl aliquots of the toluene extract by selected-ion monitoring of m/z 112 for d(0)-Crea-PFB and m/z 115 for d(3)-Crea-PFB in the electron-capture negative-ion chemical ionization mode. The limit of detection of the method is 100 amol of creatinine. In an inter-laboratory study on urine samples from 100 healthy subjects, the GC-MS method was used to test the reliability of currently used Jaffé, enzymatic and HPLC assays in clinical and occupational studies. The results of the inter-laboratory study indicate that all three tested methods allow for satisfactory quantification of creatinine in human urine. The GC-MS method is suitable for use as a reference method for urinary creatinine in humans. In serum, creatine was found to contribute to creatinine up to 20% when measured by the present GC-MS method. The application of the GC-MS method can be extended to other biological samples such as saliva. Copyright © 2010 Elsevier B.V. All rights reserved.

  3. ARSENIC SPECIATION ANALYSIS IN HUMAN SALIVA

    Science.gov (United States)

    Background: Determination of arsenic species in human saliva is potentially useful for biomonitoring of human exposure to arsenic and for studying arsenic metabolism. However, there is no report on the speciation analysis of arsenic in saliva. Methods: Arsenic species in saliva ...

  4. The pH changes of artificial saliva after interaction with oral of artificial saliva after interaction with oral micropathogen

    Directory of Open Access Journals (Sweden)

    Basri A. Gani

    2012-12-01

    Full Text Available Backgorund: Saliva contains several protein elements, exocrine proteins and antibodies, such as lactoferrin, sIgA, peroxidase, albumin, polypeptides, and oligopeptides that contribute to the defense of oral mucosa and dental pellicle to prevent infection caused by oral micropathogen, such as Candida albicans, Streptococcus mutans and Aggregatibacter actinomycetemcomitans (A. actinomycetemcomitans. Those micropathogens have a role to change salivary pH as an indicator of oral disease activities. Purpose: This study was aimed to analyze the changes of artificial saliva pH after interaction with S. mutans, C. albicans, and A. Actinomycetemcpmitans. Methods: The materials used in this study consist of S. mutans (ATCC 31987, C. albicans (ATCC 10231, A. actinomycetemcomitans (ATTC 702 358, and artificial saliva. To examine the pH changes of artificial saliva, those three microbiotas were cultured and incubated for 24 hours. Results: The results showed that the interactions of S. mutans, C. albicans, and A. actinomycetemcomitans in the artificial saliva can change the salivary on neutral. There were no significant difference with the control treatment salivary pH 4, 5, 6, 8, and 9 (p>0.05. Similarly, there was also no significant difference when those three microorganism interacted each other in the artificial saliva (p<0.05. Conclusion: It can be concluded that the biological activity of S. mutans, C. albicans, and A. actinomycetemcomitans in artificial saliva can change the salivary pH into neutral. It indicates that those microbiotas mutually supported and cooperated in influencing the biological cycle of the oral cavity with salivary pH as an indicator.Latar belakang: Saliva merupakan cairan eksokrin yang mengandung unsur protein dan antibodi seperti sIgA laktoferin peroksidase, albumin, polipeptida dan oligopeptida yang berperan pada pertahanan mukosa rongga mulut dan gigi guna mencegah infeksi oral mikropatogen seperti C. albicans, S. mutans, dan

  5. Measurements of amylase isoenzymes in sera and saliva of patients after radiotherapy because of larynx carcinoma

    International Nuclear Information System (INIS)

    Tomasik, A.; Tarnawski, R.; Wierzynski, J.; Tarnawski, R.

    1994-01-01

    Serum and salivary alpha-amylase were measured for controls and patients with laryngeal carcinoma before and after localized irradiation including salivary glands. A significant increase in amylasemia was observed after irradiation. Alpha-amylase activity in saliva was decreased after irradiation but differences were not statistically significant due to the significant decrease of protein in saliva of irradiated group. An increase of salivary isoenzyme S activity was observed while pancreatic isoenzyme activity was not altered. This method allows easy differentiation of hyperamylasemia due to irradiation of parothyroid gland and disorders of the pancreas. Alpha-amylase activity measurements may detect metabolic changes in salivary glands after irradiation. (author)

  6. Lutzomyia longipalpis saliva or salivary protein LJM19 protects against Leishmania braziliensis and the saliva of its vector, Lutzomyia intermedia.

    Directory of Open Access Journals (Sweden)

    Natalia M Tavares

    Full Text Available BACKGROUND: Leishmania transmission occurs in the presence of insect saliva. Immunity to Phlebotomus papatasi or Lutzomyia longipalpis saliva or salivary components confers protection against an infection by Leishmania in the presence of the homologous saliva. However, immunization with Lutzomyia intermedia saliva did not protect mice against Leishmania braziliensis plus Lu. intermedia saliva. In the present study, we have studied whether the immunization with Lu. longipalpis saliva or a DNA plasmid coding for LJM19 salivary protein would be protective against L. braziliensis infection in the presence of Lu. intermedia saliva, the natural vector for L. braziliensis. METHODOLOGY/PRINCIPAL FINDINGS: Immunization with Lu. longipalpis saliva or with LJM19 DNA plasmid induced a Delayed-Type Hypersensitivity (DTH response against Lu. longipalpis as well as against a Lu. intermedia saliva challenge. Immunized and unimmunized control hamsters were then intradermally infected in the ears with L. braziliensis in the presence of Lu. longipalpis or Lu. intermedia saliva. Animals immunized with Lu. longipalpis saliva exhibited smaller lesion sizes as well as reduced disease burdens both at lesion site and in the draining lymph nodes. These alterations were associated with a significant decrease in the expression levels of IL-10 and TGF-β. Animals immunized with LJM19 DNA plasmid presented similar findings in protection and immune response and additionally increased IFN-γ expression. CONCLUSIONS/SIGNIFICANCE: Immunization with Lu. longipalpis saliva or with a DNA plasmid coding LJM19 salivary protein induced protection in hamsters challenged with L. braziliensis plus Lu. intermedia saliva. These findings point out an important role of immune response against saliva components, suggesting the possibility to develop a vaccine using a single component of Lu. longipalpis saliva to generate protection against different species of Leishmania, even those

  7. Environmental Chemicals in Urine and Blood: Improving Methods for Creatinine and Lipid Adjustment

    Science.gov (United States)

    O’Brien, Katie M.; Upson, Kristen; Cook, Nancy R.; Weinberg, Clarice R.

    2015-01-01

    Background Investigators measuring exposure biomarkers in urine typically adjust for creatinine to account for dilution-dependent sample variation in urine concentrations. Similarly, it is standard to adjust for serum lipids when measuring lipophilic chemicals in serum. However, there is controversy regarding the best approach, and existing methods may not effectively correct for measurement error. Objectives We compared adjustment methods, including novel approaches, using simulated case–control data. Methods Using a directed acyclic graph framework, we defined six causal scenarios for epidemiologic studies of environmental chemicals measured in urine or serum. The scenarios include variables known to influence creatinine (e.g., age and hydration) or serum lipid levels (e.g., body mass index and recent fat intake). Over a range of true effect sizes, we analyzed each scenario using seven adjustment approaches and estimated the corresponding bias and confidence interval coverage across 1,000 simulated studies. Results For urinary biomarker measurements, our novel method, which incorporates both covariate-adjusted standardization and the inclusion of creatinine as a covariate in the regression model, had low bias and possessed 95% confidence interval coverage of nearly 95% for most simulated scenarios. For serum biomarker measurements, a similar approach involving standardization plus serum lipid level adjustment generally performed well. Conclusions To control measurement error bias caused by variations in serum lipids or by urinary diluteness, we recommend improved methods for standardizing exposure concentrations across individuals. Citation O’Brien KM, Upson K, Cook NR, Weinberg CR. 2016. Environmental chemicals in urine and blood: improving methods for creatinine and lipid adjustment. Environ Health Perspect 124:220–227; http://dx.doi.org/10.1289/ehp.1509693 PMID:26219104

  8. Multiple stage MS in analysis of plasma, serum, urine and in vitro samples relevant to clinical and forensic toxicology.

    Science.gov (United States)

    Meyer, Golo M; Maurer, Hans H; Meyer, Markus R

    2016-01-01

    This paper reviews MS approaches applied to metabolism studies, structure elucidation and qualitative or quantitative screening of drugs (of abuse) and/or their metabolites. Applications in clinical and forensic toxicology were included using blood plasma or serum, urine, in vitro samples, liquids, solids or plant material. Techniques covered are liquid chromatography coupled to low-resolution and high-resolution multiple stage mass analyzers. Only PubMed listed studies published in English between January 2008 and January 2015 were considered. Approaches are discussed focusing on sample preparation and mass spectral settings. Comments on advantages and limitations of these techniques complete the review.

  9. Determination of morphine, codeine and 6-monoacetylmorphine in saliva of substance-abuse patients using HPLC/MS methods

    Directory of Open Access Journals (Sweden)

    Milovanović Vesna

    2012-01-01

    Full Text Available Background/Aim. Saliva represents an alternative specimen for substances abuse determination in toxicology. Hence, the aim of this study was to optimize a method for saliva specimen preparation for heroin metabolites, morphine and 6-monoacetylmorphine (6-mam, and codeine determination by liquid chromatography-mass spectrometry (LC/MS, and to apply this method on saliva samples taken from the patients. Methods. Saliva specimen was prepared using liqiud/liquid extraction of morphine, codeine and 6- mam by mixture of chloroform and isopropanol (9 : 1; v/v. Extracts were analysed by HPLC/MS technique: separation column Waters Spherisorb® 5 μm, ODS2, 4.6 × 100 mm; mobile phase: ammonium acetate : acetonitile (80 : 20; v/v, mobile phase flow rate 0.3 mL/min; mass detection range: 100-400 m/z. Regression and correlation analyses were performed with the probalility level of 0.05. Concentrations of morphine, codeine and 6-mam were determined in saliva samples of the patients with “opiates” in urine identified by the test strips. Results. Calibration for each analysed substance was done in the concentration range from 0.1 to 1 mg/L and the coefficient of correlation was R2 > 0.99. We obtained following calibration curves: y = 385531x + 14584; y = 398036x + 31542; and y = 524162x - 27105, for morphine, codeine and 6-mam, respectively. Recovery for morphine and codeine determination was 99%, while for 6- mam it was 94%. Limits of detection and quantification of a proposed method were 0.01 mg/L and 0.05 mg/L, respectively. Concentration of morphine in the saliva of the heroin users ranged between 0.54 and 5.82 mg/L, concentration of codeine between 0.05 and 5.33, and 6-mam between 0.01 and 0.68 mg/L. A statistically significant correlation between codeine and 6-mam concentrations was obtained. Conclusion. A proposed HPLC/MS method for morphine, codeine and 6-mam determination in saliva is accurate, simple, cheap and suitable for routine analysis and

  10. 24-hour human urine and serum profiles of bisphenol A: Evidence against sublingual absorption following ingestion in soup

    Energy Technology Data Exchange (ETDEWEB)

    Teeguarden, Justin G., E-mail: jt@pnl.gov [Health Effects and Exposure Science, Pacific Northwest National Laboratory, Richland, WA 99352 (United States); Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, OR 93771 (United States); Twaddle, Nathan C., E-mail: nathan.twaddle@fda.hhs.gov [Division of Biochemical Toxicology, National Center for Toxicological Research, U.S. Food and Drug Administration, Jefferson, AR 72079 (United States); Churchwell, Mona I., E-mail: mona.churchwell@fda.hhs.gov [Division of Biochemical Toxicology, National Center for Toxicological Research, U.S. Food and Drug Administration, Jefferson, AR 72079 (United States); Yang, Xiaoxia, E-mail: xiaoxia.yang@fda.hhs.gov [Division of Biochemical Toxicology, National Center for Toxicological Research, U.S. Food and Drug Administration, Jefferson, AR 72079 (United States); Fisher, Jeffrey W., E-mail: jeffrey.fisher@fda.hhs.gov [Division of Biochemical Toxicology, National Center for Toxicological Research, U.S. Food and Drug Administration, Jefferson, AR 72079 (United States); Seryak, Liesel M., E-mail: seryak.2@osu.edu [Division of Epidemiology, College of Public Health, The Ohio State University, Columbus, OH 43210 (United States); Doerge, Daniel R., E-mail: daniel.doerge@fda.hhs.gov [Division of Biochemical Toxicology, National Center for Toxicological Research, U.S. Food and Drug Administration, Jefferson, AR 72079 (United States)

    2015-10-15

    Extensive first-pass metabolism of ingested bisphenol A (BPA) in the gastro-intestinal tract and liver restricts blood concentrations of bioactive BPA to < 1% of total BPA in humans and non-human primates. Absorption of ingested BPA through non-metabolizing tissues of the oral cavity, recently demonstrated in dogs, could lead to the higher serum BPA concentrations reported in some human biomonitoring studies. We hypothesized that the extensive interaction with the oral mucosa by a liquid matrix, like soup, relative to solid food or capsules, might enhance absorption through non-metabolizing oral cavity tissues in humans, producing higher bioavailability and higher serum BPA concentrations. Concurrent serum and urine concentrations of d6-BPA, and its glucuronide and sulfate conjugates, were measured over a 24 hour period in 10 adult male volunteers following ingestion of 30 μg d6-BPA/kg body weight in soup. Absorption of d6-BPA was rapid (t{sub 1/2} = 0.45 h) and elimination of the administered dose was complete 24 h post-ingestion, evidence against any tissue depot for BPA. The maximum serum d6-BPA concentration was 0.43 nM at 1.6 h after administration and represented < 0.3% of total d6-BPA. Pharmacokinetic parameters, pharmacokinetic model simulations, and the significantly faster appearance half-life of d6-BPA-glucuronide compared to d6-BPA (0.29 h vs 0.45 h) were evidence against meaningful absorption of BPA in humans through any non-metabolizing tissue (< 1%). This study confirms that typical exposure to BPA in food produces picomolar to subpicomolar serum BPA concentrations in humans, not nM concentrations reported in some biomonitoring studies.

  11. 24-hour human urine and serum profiles of bisphenol A: Evidence against sublingual absorption following ingestion in soup

    International Nuclear Information System (INIS)

    Teeguarden, Justin G.; Twaddle, Nathan C.; Churchwell, Mona I.; Yang, Xiaoxia; Fisher, Jeffrey W.; Seryak, Liesel M.; Doerge, Daniel R.

    2015-01-01

    Extensive first-pass metabolism of ingested bisphenol A (BPA) in the gastro-intestinal tract and liver restricts blood concentrations of bioactive BPA to < 1% of total BPA in humans and non-human primates. Absorption of ingested BPA through non-metabolizing tissues of the oral cavity, recently demonstrated in dogs, could lead to the higher serum BPA concentrations reported in some human biomonitoring studies. We hypothesized that the extensive interaction with the oral mucosa by a liquid matrix, like soup, relative to solid food or capsules, might enhance absorption through non-metabolizing oral cavity tissues in humans, producing higher bioavailability and higher serum BPA concentrations. Concurrent serum and urine concentrations of d6-BPA, and its glucuronide and sulfate conjugates, were measured over a 24 hour period in 10 adult male volunteers following ingestion of 30 μg d6-BPA/kg body weight in soup. Absorption of d6-BPA was rapid (t 1/2 = 0.45 h) and elimination of the administered dose was complete 24 h post-ingestion, evidence against any tissue depot for BPA. The maximum serum d6-BPA concentration was 0.43 nM at 1.6 h after administration and represented < 0.3% of total d6-BPA. Pharmacokinetic parameters, pharmacokinetic model simulations, and the significantly faster appearance half-life of d6-BPA-glucuronide compared to d6-BPA (0.29 h vs 0.45 h) were evidence against meaningful absorption of BPA in humans through any non-metabolizing tissue (< 1%). This study confirms that typical exposure to BPA in food produces picomolar to subpicomolar serum BPA concentrations in humans, not nM concentrations reported in some biomonitoring studies.

  12. Patients with dental calculus have increased saliva and gingival crevicular fluid fetuin-A levels but no association with fetuin-A polymorphisms.

    Science.gov (United States)

    Doğan, Gülnihal Emrem; Demir, Turgut; Laloğlu, Esra; Sağlam, Ebru; Aksoy, Hülya; Yildirim, Abdulkadir; Akçay, Fatih

    2016-12-22

    Fetuin-A is a potent inhibitor of calcium-phosphate precipitation and of the calcification process, therefore it can also be related with dental calculus. Thus, we aimed to investigate a possible relationship between fetuin-A gene polymorphism and the presence of dental calculus. A possible relationship between serum, saliva and gingival crevicular fluid (GCF) levels of fetuin-A was also investigated. Fetuin-A c.742C > T and c.766C > G polymorphisms were investigated in 103 patients with or without dental calculus. Additionally, serum, saliva and GCF fetuin-A levels of patients were compared according to dental calculus presence. A significant difference was not observed in the distribution of the fetuin-A c.742C > T and c.766C > G polymorphisms between patients with or without dental calculus. Saliva and GCF fetuin-A concentrations of patients with dental calculus were statistically higher than those without dental calculus (P=0.001, P=0.036 respectively). According to our results, fetuin-A c.742C > T and c.766C > G polymorphisms were not associated with presence of dental calculus. However, higher GCF and saliva fetuin-A levels were detected in patients with dental calculus than in patients without dental calculus, which may result from an adaptive mechanism to inhibit mineral precipitation and eventually calculus formation.

  13. Patients with dental calculus have increased saliva and gingival crevicular fluid fetuin-A levels but no association with fetuin-A polymorphisms

    Directory of Open Access Journals (Sweden)

    Gülnihal Emrem DOĞAN

    Full Text Available ABSTRACT: Fetuin-A is a potent inhibitor of calcium-phosphate precipitation and of the calcification process, therefore it can also be related with dental calculus. Thus, we aimed to investigate a possible relationship between fetuin-A gene polymorphism and the presence of dental calculus. A possible relationship between serum, saliva and gingival crevicular fluid (GCF levels of fetuin-A was also investigated. Fetuin-A c.742C > T and c.766C > G polymorphisms were investigated in 103 patients with or without dental calculus. Additionally, serum, saliva and GCF fetuin-A levels of patients were compared according to dental calculus presence. A significant difference was not observed in the distribution of the fetuin-A c.742C > T and c.766C > G polymorphisms between patients with or without dental calculus. Saliva and GCF fetuin-A concentrations of patients with dental calculus were statistically higher than those without dental calculus (P=0.001, P=0.036 respectively. According to our results, fetuin-A c.742C > T and c.766C > G polymorphisms were not associated with presence of dental calculus. However, higher GCF and saliva fetuin-A levels were detected in patients with dental calculus than in patients without dental calculus, which may result from an adaptive mechanism to inhibit mineral precipitation and eventually calculus formation.

  14. Radioimmunoassay of human urinary kallikrein

    International Nuclear Information System (INIS)

    Goering, W.

    1980-01-01

    Using a human urinary kallikrein, purified by means of Trasylol sepharose, it has been possible to develop a radioimmunoassay of kallikrein capable of detecting the substance down to a concentration of 0.5 ng/ml. The specific activity of the tracer labelled with 125-iodine using the Chloramine-T method was 30-70 nCi/ng of kallikrein. The antiserum titres for the antikallikrein serum were 1:20.000 up to 1:50.000. Human urine, submandibular and parotid salivae as well as pancreatic secretion in this RIA reacted in the same manner as the kallikrein standard solution. The kallikrein content in urine, as determined by the RIA was between 0 and 300 ng/ml, in the saliva between 400 and 2.000 ng/ml, and in the pancreatic juice between 300 and 12.000 ng/ml. Using human serum, only an incomplete immunological cross-reaction could be achieved. In human liquor as well as in animal preparation, no cross-reacting substances could be detected. (orig.) [de

  15. Urine nickel concentrations in nickel-exposed workers.

    Science.gov (United States)

    Bernacki, E J; Parsons, G E; Roy, B R; Mikac-Devic, M; Kennedy, C D; Sunderman, F W

    1978-01-01

    Electrothermal atomic absorption spectrometry was employed for analyses of nickel concentrations in urine samples from nickel-exposed workers in 10 occupational groups and from non-exposed workers in two control groups. Mean concentrations of nickel in urine were greatest in workers who were exposed to inhalation of aerosols of soluble nickel salts (e.g., workers in nickel plating operations and in an electrolytic nickel refinery). Less marked increases in urine nickel concentrations were found in groups of metal sprayers, nickel battery workers, bench mechanics and are welders. No significant increases in mean concentrations of nickel were found in urine samples from workers who performed grinding, buffing and polishing of nickel-containing alloys or workers in a coal gasification plant who employed Raney nickel as a hydrogenation catalyst. Measurements of nickel concentrations in urine are more sensitive and practical than measurements of serum nickel concentrations for evaluation of nickel exposures in industrial workers.

  16. Urine Galactomannan-to-Creatinine Ratio for Detection of Invasive Aspergillosis in Patients with Hematological Malignancies

    OpenAIRE

    Reischies, Frederike M. J.; Raggam, Reinhard B.; Prattes, Juergen; Krause, Robert; Eigl, Susanne; List, Agnes; Quehenberger, Franz; Strenger, Volker; Wölfler, Albert; Hoenigl, Martin

    2016-01-01

    Galactomannan (GM) testing of urine specimens may provide important advantages, compared to serum testing, such as easy noninvasive sample collection. We evaluated a total of 632 serial urine samples from 71 patients with underlying hematological malignancies and found that the urine GM/creatinine ratio, i.e., (urine GM level × 100)/urine creatinine level, which takes urine dilution into account, reliably detected invasive aspergillosis and may be a promising diagnostic tool for patients with...

  17. Investigation of mixed saliva by optoelectronic methods

    Science.gov (United States)

    Savchenko, Ekaterina; Nepomnyashchaya, Elina; Baranov, Maksim; Velichko, Elena; Aksenov, Evgenii; Bogomaz, Tatyana

    2018-04-01

    At present, saliva and its properties are being actively studied. Human saliva is a unique biological material that has potential in clinical practice. A detailed analysis of the characteristics and properties of saliva is relevant for diagnostic purposes. In this paper, the properties and characteristics of saliva are studied using optoelectronic methods: dynamic light scattering, electrophoretic light scattering and optical microscopy. Mixed saliva from a healthy patient and patient with diabetes mellitus type 2 was used as an object of the study. The dynamics of the behavior of a healthy and patient with diabetes mellitus type 2 is visible according to the results obtained. All three methods confirm hypothesis of structural changes in mixed saliva in the disease of diabetes mellitus type 2.

  18. Enhancement of Cellulose Degradation by Cattle Saliva

    Science.gov (United States)

    Seki, Yasutaka; Kikuchi, Yukiko; Kimura, Yoshihiro; Yoshimoto, Ryo; Takahashi, Masatoshi; Aburai, Kenichi; Kanai, Yoshihiro; Ruike, Tatsushi; Iwabata, Kazuki; Sugawara, Fumio; Sakai, Hideki; Abe, Masahiko; Sakaguchi, Kengo

    2015-01-01

    Saccharification of cellulose is a promising technique for producing alternative source of energy. However, the efficiency of conversion of cellulose into soluble sugar using any currently available methodology is too low for industrial application. Many additives, such as surfactants, have been shown to enhance the efficiency of cellulose-to-sugar conversion. In this study, we have examined first whether cattle saliva, as an additive, would enhance the cellulase-catalyzed hydrolysis of cellulose, and subsequently elucidated the mechanism by which cattle saliva enhanced this conversion. Although cattle saliva, by itself, did not degrade cellulose, it enhanced the cellulase-catalyzed degradation of cellulose. Thus, the amount of reducing sugar produced increased approximately 2.9-fold by the addition of cattle saliva. We also found that non-enzymatic proteins, which were present in cattle saliva, were responsible for causing the enhancement effect. Third, the mechanism of cattle saliva mediated enhancement of cellulase activity was probably similar to that of the canonical surfactants. Cattle saliva is available in large amounts easily and cheaply, and it can be used without further purification. Thus, cattle saliva could be a promising additive for efficient saccharification of cellulose on an industrial scale. PMID:26402242

  19. A review on development of analytical methods to determine monitorable drugs in serum and urine by micellar liquid chromatography using direct injection.

    Science.gov (United States)

    Esteve-Romero, Josep; Albiol-Chiva, Jaume; Peris-Vicente, Juan

    2016-07-05

    Therapeutic drug monitoring is a common practice in clinical studies. It requires the quantification of drugs in biological fluids. Micellar liquid chromatography (MLC), a well-established branch of Reverse Phase-High Performance Liquid Chromatography (RP-HPLC), has been proven by many researchers as a useful tool for the analysis of these matrices. This review presents several analytical methods, taken from the literature, devoted to the determination of several monitorable drugs in serum and urine by micellar liquid chromatography. The studied groups are: anticonvulsants, antiarrhythmics, tricyclic antidepressants, selective serotonin reuptake inhibitors, analgesics and bronchodilators. We detail the optimization strategy of the sample preparation and the main chromatographic conditions, such as the type of column, mobile phase composition (surfactant, organic solvent and pH), and detection. The finally selected experimental parameters, the validation, and some applications have also been described. In addition, their performances and advantages have been discussed. The main ones were the possibility of direct injection, and the efficient chromatographic elution, in spite of the complexity of the biological fluids. For each substance, the measured concentrations were accurate and precise at their respective therapeutic range. It was found that the MLC-procedures are fast, simple, inexpensive, ecofriendly, safe, selective, enough sensitive and reliable. Therefore, they represent an excellent alternative for the determination of drugs in serum and urine for monitoring purposes. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. A competitive immunoassay for ultrasensitive detection of Hg{sup 2+} in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering

    Energy Technology Data Exchange (ETDEWEB)

    She, Pei; Chu, Yanxin [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Liu, Chunwei; Guo, Xun [OptoTrace (Suzhou) Technologies, Inc., STE 316, Building 4, No. 218, Xinghu Street, bioBAY, Suzhou Industrial Park, Suzhou 215123 (China); Zhao, Kang [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Li, Jianguo, E-mail: lijgsd@suda.edu.cn [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Du, Haijing; Zhang, Xiang [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Wang, Hong [OptoTrace (Suzhou) Technologies, Inc., STE 316, Building 4, No. 218, Xinghu Street, bioBAY, Suzhou Industrial Park, Suzhou 215123 (China); Deng, Anping, E-mail: denganping@suda.edu.cn [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China)

    2016-02-04

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg{sup 2+}. This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg{sup 2+} and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg{sup 2+}. The ICT was able to directly detect Hg{sup 2+} without complexing due to the specific recognition of the mAb with Hg{sup 2+}. The IC{sub 50} and limit of detection (LOD) of the assay for Hg{sup 2+} detection were 0.12 ng mL{sup −1} and 0.45 pg mL{sup −1}, respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg{sup 2+} were in range of 88.3–107.3% with the relative standard deviations (RSD) of 1.5–9.5% (n = 3). The proposed ICT was used for the detection of Hg{sup 2+} in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg{sup 2+} in environmental water samples and biological serum and urine samples. - Highlights: • The proposed ICT was able to directly detect Hg{sup 2+} without formation of Hg{sup 2+}-ligand complex. • The proposed ICT exhibited high sensitivity, specificity, stability, precision and accuracy for Hg{sup 2+} detection. • The proposed ICT was applicable for the detection of trace amount of Hg{sup 2+} in water, human serum and urine samples.

  1. Rapid colorimetric detection of Zika virus from serum and urine specimens by reverse transcription loop-mediated isothermal amplification (RT-LAMP.

    Directory of Open Access Journals (Sweden)

    Amanda E Calvert

    Full Text Available Zika virus (ZIKV has emerged as a major global public health concern in the last two years due to its link as a causative agent of human birth defects. Its rapid expansion into the Western Hemisphere as well as the ability to be transmitted from mother to fetus, through sexual transmission and possibly through blood transfusions has increased the need for a rapid and expansive public health response to this unprecedented epidemic. A non-invasive and rapid ZIKV diagnostic screening assay that can be performed in a clinical setting throughout pregnancy is vital for prenatal care of women living in areas of the world where exposure to the virus is possible. To meet this need we have developed a sensitive and specific reverse transcriptase loop-mediated isothermal amplification (RT-LAMP assay to detect ZIKV RNA in urine and serum with a simple visual detection. RT-LAMP results were shown to have a limit of detection 10-fold higher than qRT-PCR. As little as 1.2 RNA copies/μl was detected by RT-LAMP from a panel of 178 diagnostic specimens. The assay was shown to be highly specific for ZIKV RNA when tested with diagnostic specimens positive for dengue virus (DENV and chikungunya virus (CHIKV. The assay described here illustrates the potential for a fast, reliable, sensitive and specific assay for the detection of ZIKV from urine or serum that can be performed in a clinical or field setting with minimal equipment and technological expertise.

  2. [Sampling, storage and transport of biological materials collected from living and deceased subjects for determination of concentration levels of ethyl alcohol and similarly acting substances. A proposal of updating the blood and urine sampling protocol].

    Science.gov (United States)

    Wiergowski, Marek; Reguła, Krystyna; Pieśniak, Dorota; Galer-Tatarowicz, Katarzyna; Szpiech, Beata; Jankowski, Zbigniew

    2007-01-01

    The present paper emphasizes the most common mistakes committed at the beginning of an analytical procedure. To shorten the time and decrease the cost of determinations of substances with similar to alcohol activity, it is postulated to introduce mass-scale screening analysis of saliva collected from a living subject at the site of the event, with all positive results confirmed in blood or urine samples. If no saliva sample is collected for toxicology, a urine sample, allowing for a stat fast screening analysis, and a blood sample, to confirm the result, should be ensured. Inappropriate storage of a blood sample in the tube without a preservative can cause sample spilling and its irretrievable loss. The authors propose updating the "Blood/urine sampling protocol", with the updated version to be introduced into practice following consultations and revisions.

  3. 24-hour human urine and serum profiles of bisphenol A: Evidence against sublingual absorption following ingestion in soup.

    Science.gov (United States)

    Teeguarden, Justin G; Twaddle, Nathan C; Churchwell, Mona I; Yang, Xiaoxia; Fisher, Jeffrey W; Seryak, Liesel M; Doerge, Daniel R

    2015-10-15

    Extensive first-pass metabolism of ingested bisphenol A (BPA) in the gastro-intestinal tract and liver restricts blood concentrations of bioactive BPA to <1% of total BPA in humans and non-human primates. Absorption of ingested BPA through non-metabolizing tissues of the oral cavity, recently demonstrated in dogs, could lead to the higher serum BPA concentrations reported in some human biomonitoring studies. We hypothesized that the extensive interaction with the oral mucosa by a liquid matrix, like soup, relative to solid food or capsules, might enhance absorption through non-metabolizing oral cavity tissues in humans, producing higher bioavailability and higher serum BPA concentrations. Concurrent serum and urine concentrations of d6-BPA, and its glucuronide and sulfate conjugates, were measured over a 24hour period in 10 adult male volunteers following ingestion of 30μg d6-BPA/kg body weight in soup. Absorption of d6-BPA was rapid (t1/2=0.45h) and elimination of the administered dose was complete 24h post-ingestion, evidence against any tissue depot for BPA. The maximum serum d6-BPA concentration was 0.43nM at 1.6h after administration and represented <0.3% of total d6-BPA. Pharmacokinetic parameters, pharmacokinetic model simulations, and the significantly faster appearance half-life of d6-BPA-glucuronide compared to d6-BPA (0.29h vs 0.45h) were evidence against meaningful absorption of BPA in humans through any non-metabolizing tissue (<1%). This study confirms that typical exposure to BPA in food produces picomolar to subpicomolar serum BPA concentrations in humans, not nM concentrations reported in some biomonitoring studies. Published by Elsevier Inc.

  4. Monocyte chemoattractant protein-1 and interleukin-8 levels in urine and serum of patents with hemolytic uremic syndrome.

    Science.gov (United States)

    van Setten, P A; van Hinsbergh, V W; van den Heuvel, L P; Preyers, F; Dijkman, H B; Assmann, K J; van der Velden, T J; Monnens, L A

    1998-06-01

    The epidemic form of the hemolytic uremic syndrome (HUS) in children is hallmarked by endothelial cell damage, most predominantly displayed by the glomerular capillaries. The influx of mononuclear (MO) and polymorphonuclear cells (PMNs) into the glomeruli may be an important event in the initiation, prolongation, and progression of glomerular endothelial cell damage in HUS patients. The molecular mechanisms for the recruitment of these leukocytes into the kidney are unclear, but monocyte chemoattractant protein-1 (MCP-1) and IL-8 are suggested to be prime candidates. In this study, we analyzed the presence of both chemokines in 24-h urinary (n = 15) and serum (n = 14) samples of HUS children by specific ELISAs. Furthermore, kidney biopsies of three different HUS children were examined for MO and PMN cell infiltration by histochemical techniques and electron microscopy. Whereas the chemokines MCP-1 and IL-8 were present in only very limited amounts in urine of 17 normal control subjects, serial samples of HUS patients demonstrated significantly elevated levels of both chemokines. HUS children with anuria showed higher initial and maximum chemokine levels than their counterparts without anuria. A strong positive correlation was observed between urinary MCP-1 and IL-8 levels. Whereas initial serum IL-8 levels were significantly increased in HUS children, serum MCP-1 levels were only slightly elevated compared with serum MCP-1 in control children. No correlation was found between urinary and serum chemokine concentrations. Histologic and EM studies of HUS biopsy specimens clearly showed the presence of MOs and to a lesser extent of PMNs in the glomeruli. The present data suggest an important local role for MOs and PMNs in the process of glomerular endothelial-cell damage. The chemokines MCP-1 and IL-8 may possibly be implicated in the pathogenesis of HUS through the recruitment and activation of MOs and PMNs, respectively.

  5. Conversion to Sirolimus Ameliorates Cyclosporine-Induced Nephropathy in the Rat: Focus on Serum, Urine, Gene, and Protein Renal Expression Biomarkers

    Directory of Open Access Journals (Sweden)

    José Sereno

    2014-01-01

    Full Text Available Protocols of conversion from cyclosporin A (CsA to sirolimus (SRL have been widely used in immunotherapy after transplantation to prevent CsA-induced nephropathy, but the molecular mechanisms underlying these protocols remain nuclear. This study aimed to identify the molecular pathways and putative biomarkers of CsA-to-SRL conversion in a rat model. Four animal groups (n=6 were tested during 9 weeks: control, CsA, SRL, and conversion (CsA for 3 weeks followed by SRL for 6 weeks. Classical and emergent serum, urinary, and kidney tissue (gene and protein expression markers were assessed. Renal lesions were analyzed in hematoxylin and eosin, periodic acid-Schiff, and Masson’s trichrome stains. SRL-treated rats presented proteinuria and NGAL (serum and urinary as the best markers of renal impairment. Short CsA treatment presented slight or even absent kidney lesions and TGF-β, NF-κβ, mTOR, PCNA, TP53, KIM-1, and CTGF as relevant gene and protein changes. Prolonged CsA exposure aggravated renal damage, without clear changes on the traditional markers, but with changes in serums TGF-β and IL-7, TBARs clearance, and kidney TGF-β and mTOR. Conversion to SRL prevented CsA-induced renal damage evolution (absent/mild grade lesions, while NGAL (serum versus urine seems to be a feasible biomarker of CsA replacement to SRL.

  6. Vaccination of Sheep with a Methanogen Protein Provides Insight into Levels of Antibody in Saliva Needed to Target Ruminal Methanogens.

    Directory of Open Access Journals (Sweden)

    Supatsak Subharat

    Full Text Available Methane is produced in the rumen of ruminant livestock by methanogens and is a major contributor to agricultural greenhouse gases. Vaccination against ruminal methanogens could reduce methane emissions by inducing antibodies in saliva which enter the rumen and impair ability of methanogens to produce methane. Presently, it is not known if vaccination can induce sufficient amounts of antibody in the saliva to target methanogen populations in the rumen and little is known about how long antibody in the rumen remains active. In the current study, sheep were vaccinated twice at a 3-week interval with a model methanogen antigen, recombinant glycosyl transferase protein (rGT2 formulated with one of four adjuvants: saponin, Montanide ISA61, a chitosan thermogel, or a lipid nanoparticle/cationic liposome adjuvant (n = 6/formulation. A control group of sheep (n = 6 was not vaccinated. The highest antigen-specific IgA and IgG responses in both saliva and serum were observed with Montanide ISA61, which promoted levels of salivary antibodies that were five-fold higher than the second most potent adjuvant, saponin. A rGT2-specific IgG standard was used to determine the level of rGT2-specific IgG in serum and saliva. Vaccination with GT2/Montanide ISA61 produced a peak antibody concentration of 7 × 1016 molecules of antigen-specific IgG per litre of saliva, and it was estimated that in the rumen there would be more than 104 molecules of antigen-specific IgG for each methanogen cell. Both IgG and IgA in saliva were shown to be relatively stable in the rumen. Salivary antibody exposed for 1-2 hours to an in vitro simulated rumen environment retained approximately 50% of antigen-binding activity. Collectively, the results from measuring antibody levels and stablility suggest a vaccination-based mitigation strategy for livestock generated methane is in theory feasible.

  7. Surface plasmon resonance immunoassay analysis of pituitary hormones in urine and serum samples.

    Science.gov (United States)

    Treviño, Juan; Calle, Ana; Rodríguez-Frade, José Miguel; Mellado, Mario; Lechuga, Laura M

    2009-05-01

    Direct determination of four pituitary peptide hormones: human thyroid stimulating hormone (hTSH), growth hormone (hGH), follicle stimulating hormone (hFSH), and luteinizing hormone (hLH) has been carried out using a portable surface plasmon resonance (SPR) immunosensor. A commercial SPR biosensor was employed. The immobilization of the hormones was optimized and monoclonal antibodies were selected in order to obtain the best sensor performance. Assay parameters as running buffer and regeneration solution composition or antibody concentration were adjusted to achieve a sensitive analyte detection. The performance of the assays was assessed in buffer solution, serum and urine, showing sensitivity in the range from 1 to 6 ng/mL. The covalent attachment of the hormones ensured the stability of the SPR signal through repeated use in up to 100 consecutive assay cycles. Mean intra- and inter-day coefficients of variation were all <7%, while batch-assay variability using different sensor surfaces was <5%. Taking account both the excellent reutilization performance and the outstanding reproducibility, this SPR immunoassay method turns on a highly reliable tool for endocrine monitoring in laboratory and point-of-care (POC) settings.

  8. A urine midmolecule osteocalcin assay shows higher discriminatory power than a serum midmolecule osteocalcin assay during short-term alendronate treatment of osteoporotic patients.

    Science.gov (United States)

    Srivastava, A K; Mohan, S; Singer, F R; Baylink, D J

    2002-07-01

    We isolated and characterized a peptide fragment corresponding to amino acid sequence 14-28 of human osteocalcin in urine from Paget's disease, and developed a polyclonal antibody reactive to this peptide in urine. We used this antibody to measure urinary fragments of osteocalcin and compared to efficacy of the urinary osteocalcin assay with a serum osteocalcin (sOC) assay (ELISA-Osteo, Cis-Bio International) to monitor the short-term changes in bone turnover in response to alendronate treatment. The synthetic peptide-based urinary osteocalcin (uOC) radioimmunoassay (RIA) showed an analytical sensitivity of 6.25 ng/mL, standard curve range of 3.12-400 ng/mL, and mean intra- (n = 20) and interassay (n = 30) coefficient of variation (CV) of sALP) (Alkphose-B, Metra Biosystems) in serum samples. The percent change data obtained between baseline and 30 days (n = 18) posttreatment suggested a rapid decline in uOC concentration (-27%, p sALP (-3.4%, p = 0.689), two specific markers of bone formation. As expected, due to the coupling of bone formation and bone resorption, the concentration of all markers showed a 30%-45% decline compared with baseline values after 90 days (n = 16) of treatment. Correlation of markers after a 30 day treatment with alendronate revealed a higher correlation (r = 0.61, p sALP (r = -0.14, p = 0.295) with uNTx. Similarly, correlation coefficients with r values between 0.48 and 0.55 (p < 0.05) were observed between uOC, sNTx, and sCTx, whereas no significant correlation was observed between sOC and sNTx or sCTx. These results provide indirect evidence that fragments measured by the urine assay probably originated from bone resorption, and suggest that the uOC assay could be used to assess short-term changes in bone metabolism with regard to osteocalcin.

  9. SALIVA AS A DIAGNOSTIC FLUID

    Directory of Open Access Journals (Sweden)

    Pezelj-Ribarić Sonja

    2015-12-01

    Full Text Available Saliva is a readily available oral fluid with many functions, from digestion, maintenance of oral tissues' integrity, to caries prevention. Changes regarding its secretion may be divided into qualitative and quantitative: both of them are a consequence of certain conditions/diseases (e.g. internal factors or nutrients/drugs ingested (e.g. external factors. During the last 15 years, technological advances gave a significant momentum to utilization of saliva as a diagnostic tool. Analysis of saliva, just like the blood analysis, has two main objectives: to identify the subjects suffering from a certain disorder, and to follow the development and progress of therapy. This paper provides an overview of possibilities for the use of saliva for diagnostic purposes and gives specific examples of some clinical investigations, with the final aim to stimulate the use of this noninvasive means for the health care promotion.

  10. Short communication: Ability of dogs to detect cows in estrus from sniffing saliva samples.

    Science.gov (United States)

    Fischer-Tenhagen, C; Tenhagen, B-A; Heuwieser, W

    2013-02-01

    Efficient estrus detection in high-producing dairy cows is a permanent challenge for successful reproductive performance. In former studies, dogs have been trained to identify estrus-specific odor in vaginal fluid, milk, urine, and blood samples under laboratory conditions with an accuracy of more than 80%. For on-farm utilization of estrus-detection dogs it would be beneficial in terms of hygiene and safety if dogs could identify cows from the feed alley. The objective of this proof of concept study was to test if dogs can be trained to detect estrus-specific scent in saliva of cows. Saliva samples were collected from cows in estrus and diestrus. Thirteen dogs of various breeds and both sexes were trained in this study. Five dogs had no experience in scent detection, whereas 8 dogs had been formerly trained for detection of narcotics or cancer. In the training and test situation, dogs had to detect 1 positive out of 4 samples. Dog training was based on positive reinforcement and dogs were rewarded with a clicker and food for indicating saliva samples of cows in estrus. A false indication was ignored and documented in the test situation. Dogs with and without prior training were trained for 1 and 5 d, respectively. For determining the accuracy of detection, the position of the positive sample was unknown to the dog handler, to avoid hidden cues to the dog. The overall percentage of correct positive indications was 57.6% (175/304), with a range from 40 (1 dog) to 75% (3 dogs). To our knowledge, this is the first indication that dogs are able to detect estrus-specific scent in saliva of cows. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  11. Contribution of targeted saliva screening for congenital CMV-related hearing loss in newborns who fail hearing screening.

    Science.gov (United States)

    Ari-Even Roth, Daphne; Lubin, Daniel; Kuint, Jacob; Teperberg-Oikawa, Michal; Mendelson, Ella; Strauss, Tzipora; Barkai, Galia

    2017-11-01

    We previously reported a 2.2% rate of infants born with sensorineural hearing loss (SNHL) due to congenital cytomegalovirus (cCMV) infection identified by universal neonatal screen for cCMV using saliva. To evaluate the contribution of targeted saliva screening for cCMV to the detection of infants born with cCMV-related SNHL who failed universal newborn hearing screening (UNHS). We retrospectively reviewed the audiological and medical records of infants who failed UNHS and were tested for cCMV using saliva sample prior to discharge at Sheba Medical Center between 2014 and 2015. Positive cases were confirmed by urine sample. Two hundred (1%) of the 19 830 infants tested during the study period failed in-hospital hearing screening. A saliva specimen was obtained prior to discharge in 187 infants (93.5% of those who failed UNHS). In 178 infants saliva testing was performed at ≤21 days of chronological age and yielded results. cCMV infection was identified in 4/178 tested infants (2.25%, 95% CI 0.8% to 5.3%), of whom three were diagnosed with SNHL (1.7%, 95% CI 0.5% to 4.4%) and offered antiviral treatment. Two of the tested infants (1.12%, 95% CI 0.2% to 3.6%) were diagnosed with cCMV solely due to failure in UNHS. Occult central nervous system (CNS) symptoms of cCMV infection were detected in 2/4 infants following targeted investigation. Targeted cCMV screening in newborns who failed UNHS contributed to the early detection of infants born with cCMV-related isolated SNHL or with occult CNS symptoms who could potentially benefit from antiviral treatment. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Albumin adsorption onto surfaces of urine collection and analysis containers.

    Science.gov (United States)

    Robinson, Mary K; Caudill, Samuel P; Koch, David D; Ritchie, James; Hortin, Glen; Eckfeldt, John H; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W Greg

    2014-04-20

    Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. We added (125)I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Adsorption of urine albumin (UA) at 5-6 mg/l was containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2-28%) was larger than that from urine. Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Radioimmunoassay of bleomycin in plasma and urine

    International Nuclear Information System (INIS)

    Teale, J.D.; Clough, J.M.; Marks, V.

    1977-01-01

    Antibodies to bleomycin were raised by immunization of sheep and rabbits with bleomycin-albumin conjugates. The combination of a high-titre, high-avidity sheep antiserum and iodinated bleomycin produced a radioimmunoassay sensitive to 8 ng of bleomycin per ml of plasma or urine. Untreated specimens (100 μl) of plasma or urine could be added directly to the assay tubes. The anti-serum was specific for bleomycin and showed no cross-reaction with other anti-cancer agents used in combination chemotherapy. Over a concentration range of 20 to 100 ng/ml. recovery of bleomycin from plasma was 110% and from urine, 93%. Repeated assay of plasma samples showed a decrease in bleomycin levels unless the samples were kept at 4 0 C or below. Assay of bleomycin levels in plasma and urine from patients under treatment with bleomycin showed similarities with results reported using a microbiological assay. The radioimmunoassay offers a more reliable, rapid and sensitive method for the measurement of bleomycin. (author)

  14. Chemotherapy-induced gastrointestinal toxicity is associated with changes in serum and urine metabolome and fecal microbiota in male Sprague-Dawley rats.

    Science.gov (United States)

    Forsgård, Richard A; Marrachelli, Vannina G; Korpela, Katri; Frias, Rafael; Collado, Maria Carmen; Korpela, Riitta; Monleon, Daniel; Spillmann, Thomas; Österlund, Pia

    2017-08-01

    Chemotherapy-induced gastrointestinal toxicity (CIGT) is a complex process that involves multiple pathophysiological mechanisms. We have previously shown that commonly used chemotherapeutics 5-fluorouracil, oxaliplatin, and irinotecan damage the intestinal mucosa and increase intestinal permeability to iohexol. We hypothesized that CIGT is associated with alterations in fecal microbiota and metabolome. Our aim was to characterize these changes and examine how they relate to the severity of CIGT. A total of 48 male Sprague-Dawley rats were injected intraperitoneally either with 5-fluorouracil (150 mg/kg), oxaliplatin (15 mg/kg), or irinotecan (200 mg/kg). Body weight change was measured daily after drug administration and the animals were euthanized after 72 h. Blood, urine, and fecal samples were collected at baseline and at the end of the experiment. The changes in the composition of fecal microbiota were analyzed with 16S rRNA gene sequencing. Metabolic changes in serum and urine metabolome were measured with 1 mm proton nuclear magnetic resonance ( 1 H-NMR). Irinotecan increased the relative abundance of Fusobacteria and Proteobacteria, while 5-FU and oxaliplatin caused only minor changes in the composition of fecal microbiota. All chemotherapeutics increased the levels of serum fatty acids and N(CH 3 ) 3 moieties and decreased the levels of Krebs cycle metabolites and free amino acids. Chemotherapeutic drugs, 5-fluorouracil, oxaliplatin, and irinotecan, induce several microbial and metabolic changes which may play a role in the pathophysiology of CIGT. The observed changes in intestinal permeability, fecal microbiota, and metabolome suggest the activation of inflammatory processes.

  15. 24-hour human urine and serum profiles of bisphenol A following ingestion in soup: Individual pharmacokinetic data and emographics

    Directory of Open Access Journals (Sweden)

    Justin G. Teeguarden

    2015-09-01

    Full Text Available Here we present data to evaluate potential absorption of Bisphenol A through non-metabolizing tissues of the upper digestive tract. Concurrent serum and urine concentrations of d6-BPA, and its glucuronide and sulfate conjugates, were measured over a 24 h period in 10 adult male volunteers following ingestion of 30 μg d6-BPA/kg body weight in soup. The pharmacokinetic behavior of BPA and its metabolites in this cohort (rapid absorption, complete elimination, evidence against sublingual absorption was reported. This Data in Brief article contains the corresponding individual pharmacokinetic data, reports the demographics of the cohort and provides additional details related to the analytical methods employed and is related to [4].

  16. 24-hour human urine and serum profiles of bisphenol A following ingestion in soup: Individual pharmacokinetic data and emographics

    Science.gov (United States)

    Teeguarden, Justin G.; Twaddle, Nathan C.; Churchwell, Mona I.; Yang, Xiaoxia; Fisher, Jeffrey W.; Seryak, Liesel M.; Doerge, Daniel R.

    2015-01-01

    Here we present data to evaluate potential absorption of Bisphenol A through non-metabolizing tissues of the upper digestive tract. Concurrent serum and urine concentrations of d6-BPA, and its glucuronide and sulfate conjugates, were measured over a 24 h period in 10 adult male volunteers following ingestion of 30 μg d6-BPA/kg body weight in soup. The pharmacokinetic behavior of BPA and its metabolites in this cohort (rapid absorption, complete elimination, evidence against sublingual absorption) was reported. This Data in Brief article contains the corresponding individual pharmacokinetic data, reports the demographics of the cohort and provides additional details related to the analytical methods employed and is related to [4]. PMID:26217767

  17. Serum and Urine Markers of Collagen Type VI Formation (Pro-C6) and Type III Degradation (C3M) Reflect Renal Function in Type 1 Diabetes

    DEFF Research Database (Denmark)

    Hansen, Tine Wilum; Guldager, Daniel Kring Rasmussen; Pilemann-Lyberg, Sascha

    ). We applied unadjusted and adjusted linear regression analyses.Adjustment included age, sex, LDL cholesterol, smoking, HbA1c, systolic blood pressure, UAER (in analyses of eGFR) and eGFR (in analyses of UAER). To adjust for urine output levels, the urinary markers were normalized for urinary...... (unadjusted: plost after adjustment (p=0.43). Higher serum levels of C3M were associated with lower e...

  18. White Light Generation in Human Saliva

    Science.gov (United States)

    Santhosh, C.; Dharmadhikari, A. K.; Dharmadhikari, J. A.; Alti, K.; Mathur, D.

    2011-07-01

    Interaction of intense, femto-second pulses of infrared light (800 nm) with water generates white light supercontinuum due to nonlinear optical effects. This supercontinuum was found to be suppressed by the addition of alpha amylase, a major protein in the human saliva. We have studied the suppression of supper continuum by human saliva, collected from healthy subjects with and without smoking habits. Suppression of the blue-sided components was observed significantly in non-smokers saliva than chain smokers.

  19. Urine Galactomannan-to-Creatinine Ratio for Detection of Invasive Aspergillosis in Patients with Hematological Malignancies.

    Science.gov (United States)

    Reischies, Frederike M J; Raggam, Reinhard B; Prattes, Juergen; Krause, Robert; Eigl, Susanne; List, Agnes; Quehenberger, Franz; Strenger, Volker; Wölfler, Albert; Hoenigl, Martin

    2016-03-01

    Galactomannan (GM) testing of urine specimens may provide important advantages, compared to serum testing, such as easy noninvasive sample collection. We evaluated a total of 632 serial urine samples from 71 patients with underlying hematological malignancies and found that the urine GM/creatinine ratio, i.e., (urine GM level × 100)/urine creatinine level, which takes urine dilution into account, reliably detected invasive aspergillosis and may be a promising diagnostic tool for patients with hematological malignancies. (This study has been registered at ClinicalTrials.gov under registration no. NCT01576653.). Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  20. The functions of human saliva

    DEFF Research Database (Denmark)

    Dawes, C; Pedersen, Anne Marie Lynge; Villa, A

    2015-01-01

    This narrative review of the functions of saliva was conducted in the PubMed, Embase and Web of Science databases. Additional references relevant to the topic were used, as our key words did not generate references which covered all known functions of saliva. These functions include maintaining a...... of oral wounds. Clearly, saliva has many functions which are needed for proper protection and functioning of the human body....... a moist oral mucosa which is less susceptible to abrasion, and removal of micro-organisms, desquamated epithelial cells, leucocytes and food debris by swallowing. The mucins form a slimy coating on all surfaces in the mouth and act as a lubricant during such processes as mastication, formation of a food...

  1. Factors That Influence the Extensional Rheological Property of Saliva.

    Directory of Open Access Journals (Sweden)

    Amrita Vijay

    Full Text Available The spinnbarkeit of saliva reflects the ability of saliva to adhere to surfaces within the mouth, thereby serving as a protective role and aiding in lubrication. Therefore, alterations in the extensional rheology of saliva may result in the loss in adhesiveness or the ability to bind onto surfaces. Mucin glycoproteins and their structures are known to be important factors for the extensional rheological properties of saliva. The conformation of mucin depends on factors such as pH and ionic strength. Chewing is one of the main stimuli for salivary secretion but creates significant sheer stress on the salivary film which could influence mouthfeel perceptions. The current study investigates the possible factors which affect the extensional rheological properties of saliva by comparing submandibular/sublingual saliva with different oral stimuli within the same group of subjects. Unstimulated and stimulated saliva (chew, smell and taste salivas were collected primarily from submandibular/sublingual glands. The saliva samples were measured for Spinnbarkeit followed by the measuring mucin, total protein, total calcium and bicarbonate concentrations. The results indicated correlations between rheological properties and mucin/ion concentrations. However, chewing stimulated submandibular/sublingual saliva is shown to have significantly lower Spinnbarkeit, but factors such as mucin, protein and calcium concentrations did not account for this variation. Analysis of the concentration of bicarbonate and pH appears to suggest that it has a prominent effect on extensional rheology of saliva.

  2. Astronaut Bones: Stable Calcium Isotopes in Urine as a Biomarker of Bone Mineral Balance

    Science.gov (United States)

    Skulan, J.; Gordon, G. W.; Romaniello, S. J.; Anbar, A. D.; Smith, S. M.; Zwart, S.

    2016-12-01

    Bone loss is a common health concern, in conditions ranging from osteoporosis to cancer. Bone loss due to unloading is also an important health issue for astronauts. We demonstrate stable calcium isotopes, a tool developed in geochemistry, are capable of detecting real-time quantitative changes in net bone mineral balance (BMB) using serum and urine [1]. We validated this technique by comparing with DEXA and biomarker data in subjects during bed rest, a ground-based analog of space flight effects [2-4]. We now apply this tool to assess changes in astronauts' BMB before, during and after 4-6 month space missions. There is stable isotope fractionation asymmetry between bone formation and resorption. During bone formation there is a mass-dependent preference for "lighter" calcium isotopes to be removed from serum and incorporated into bone mineral. During bone resorption, there is no measurable isotopic discrimination between serum and bone. Hence, when bone formation rates exceed that of resorption, serum and urine become isotopically "heavy" due to the sequestration of "light" calcium in bone. Conversely, when bone resorption exceeds bone formation, serum and urine become isotopically "light" due to the release of the sequestered light calcium from bone. We measured Ca isotopes in urine of thirty International Space Station astronauts. Average Ca isotope values in astronauts' urine shift isotopically lighter during microgravity, consistent with negative net BMB. Within a month of return to Earth, astronauts returned to within error of their δ44Ca value prior to departure. Urine samples from astronauts testing bone loss countermeasures showed bisphosphonates provide a viable pharmacological countermeasure. Some, but not all, individuals appear able to resist bone loss through diet and intensive resistive exercise alone. This is a promising new technique for monitoring BMB in astronauts, and hopefully someday on the way to/from Mars, this also has important clinical

  3. TRH radioimmunoassay for unextracted human urine

    International Nuclear Information System (INIS)

    Mitsuma, Terunori; Hirooka, Yoshibumi; Nihei, Noriyuki

    1975-01-01

    The authors developed a TRH radioimmunoassay for unextracted human urine using anti-TRH antibody produced by immunization of rabbits with a TRH-bis-diazotized-bovine serum albumin conjugate. The antibody had no crossreactivity with TRH analogues, amino acids or pituitary hormones, but with L or DL-Aze3-TRH. TRH was radioiodinized by Greenwood-Hunter's method, followed by purification on Sephadex G-10. Inactivation of TRH by serum was well documented. The authors found however that this inactivation of TRH could be prevented by adjusting the pH to 3.0 or by keeping the temperature between 4 0 C and -20 0 C. All assay procedures were performed in 0.01 M phosphate buffer with 0.15 M NaCl (pH 7.5) at 4 0 C. Free and bound forms were separated with a second antibody system. In this system, sensitivity was 0.01 ng/tube, recovery was approximately 100%, intrassay reproducibility was 3.2% and interassay variation was 9.8%. TRH levels in urine measured with this system were undetectable to 9.0 ng/ml in normal subjects, undetectable in hyperthyroid patients or a tertiary hypothyroid patient and 13 to 24 ng/ml in primary hypothyroid patients. Approximately 6 percent of the intravenously administered TRH was excreted into the urine within 12 hours following administration in a normal subject. As a result this assay system is quite attractive for clinical determination as well as research application. (Evans, J.)

  4. Clinical significance of myoglobinuria and serum myoglobin in heroin-addicted patients

    International Nuclear Information System (INIS)

    Chen Xuehong; Zhong Ganping; Zhang Lan; Liu Jiangyan

    2001-01-01

    The authors study the relationship between myoglobinuria and acute rhabdomyolysis in heroin-addicted patients. The levels of myoglobin in serum and urine were determined by RIA in 106 heroin-addicted patients and 30 healthy volunteers who were selected as the controls. The levels of myoglobin in serum and urine increased significantly in heroin-addicted patients in 3 days after giving up heroin, and gradually decreased in 2 weeks but still higher than the levels of the controls (P 0.05). Urine myoglobin detection is a simple and effective method to find out acute rhabdomyolysis derived from heroin addiction early

  5. The application of micro-coil NMR probe technology to metabolomics of urine and serum

    International Nuclear Information System (INIS)

    Grimes, John H.; O’Connell, Thomas M.

    2011-01-01

    Increasing the sensitivity and throughput of NMR-based metabolomics is critical for the continued growth of this field. In this paper the application of micro-coil NMR probe technology was evaluated for this purpose. The most commonly used biofluids in metabolomics are urine and serum. In this study we examine different sample limited conditions and compare the detection sensitivity of the micro-coil with a standard 5 mm NMR probe. Sample concentration is evaluated as a means to leverage the greatly improved mass sensitivity of the micro-coil probes. With very small sample volumes, the sensitivity of the micro-coil probe does indeed provide a significant advantage over the standard probe. Concentrating the samples does improve the signal detection, but the benefits do not follow the expected linear increase and are both matrix and metabolite specific. Absolute quantitation will be affected by concentration, but an analysis of relative concentrations is still possible. The choice of the micro-coil probe over a standard tube based probe will depend upon a number of factors including number of samples and initial volume but this study demonstrates the feasibility of high-throughput metabolomics with the micro-probe platform.

  6. Recuperación de veillonellas a partir de saliva Recovery of Veillonella from saliva

    Directory of Open Access Journals (Sweden)

    M.I. Gutiérrez De Ferro

    2005-03-01

    Full Text Available Las veillonellas son cocos gram-negativos anaerobios asociados con salud oral. Para su aislamiento, se han reportado diferentes medios de cultivo. Las colonias de Veillonella spp. producen fluorescencia roja visible con luz ultravioleta, que desaparece en contacto con oxígeno. Esta propiedad sería útil para su identificación presuntiva rápida. Los objetivos de este trabajo fueron: 1- comparar el medio selectivo para Veillonella de Rogosa con los medios de cultivo recomendados por diferentes autores para determinar en cual de ellos se obtiene una mejor recuperación de veillonellas a partir de saliva, ya que esta muestra es generalmente utilizada para determinar la presencia y predominio de esta bacteria; 2- detectar la producción de fluorescencia en estos medios de cultivo como método rápido de identificación. Los medios de cultivo estudiados fueron: medio selectivo para Veillonella, agar Schaedler para anaerobios con vitamina K, agar tioglicolato, agar infusión cerebro corazón, agar Brucella, agar tripteína soja y agar Columbia con y sin el agregado de vancomicina y sangre lacada. La muestra ensayada fue un pool de saliva. Se hicieron recuentos de colonias de veillonellas y de microorganismos totales expresados en UFC/ml de saliva. La mayor recuperación de veillonellas en saliva se obtuvo en el medio selectivo para Veillonella con vancomicina y sangre lacada. Sólo se observó producción de fluorescencia en este medio.Veillonella spp. are anaerobic gram-negative cocci associated to oral health. Different types of cultures have been reported for the isolation of these microorganisms. Veillonella spp. colonies produce a red fluorescence, which is made visible through ultraviolet light and disappears in contact with oxygen. This feature would be very useful for rapid presumptive identification. The aims of this study were: 1. to compare the Rogosa selective medium for Veillonella with the cultures recommended by different authors in

  7. Molecular neutron activation analysis of selenium metabolites in urine

    International Nuclear Information System (INIS)

    Blotcky, A.J.; Hansen, G.T.; Ebrahim, A.; Rack, E.P.

    1988-01-01

    Because of the biological importance of selenium in living biological systems, various analytical procedures have been developed for analysis of microquantities of elemental selenium, in urine, serum, and tissue. For urine selenium, these include atomic absorption spectrometry, solution absorption spectrometry, solution fluorescence spectrometry, volumetry, and neutron activation analysis. Of equal or greater importance is the determination of selenium metabolites present in urine for the purpose of describing the biological pathways for the metabolism of selenium in living organisms. While it is known from previous studies that trimethylselenonium ion (TMSe) is a major metabolite in urine, probably the result of reduction and methylation reaction, there are no definitive results in the literature indicating the nature or quantity of other selenium metabolic products in urine. Early techniques to measure TMSe levels in urine involved the use of the radiotracer 75 Se. Because of the long biological half-life of selenium and issues of radiation exposure, its use in humans has been limited. In this paper, the authors report the experimental procedure for the determination of total selenoamino acid concentration in urine and present total selenium values, and, where applicable, TMSe, SeO 2- 3 , and total selenoamino acid concentrations in the urine of normal and diseased subjects

  8. Human metabolism of [1-methyl-14C]- and [2-14C]caffeine after oral administration

    International Nuclear Information System (INIS)

    Callahan, M.M.; Robertson, R.S.; Arnaud, M.J.; Branfman, A.R.; McComish, M.F.; Yesair, D.W.

    1982-01-01

    Radiolabeled caffeine was administered orally at 5 mg/kg to adult, male volunteers. Blood, saliva, expired CO2, urine, and feces were collected and analyzed for total radiolabeled equivalents, caffeine, and its metabolites. High-performance liquid chromatography (HPLC) was the principal technique used to separate caffeine and the various metabolites with quantitation by liquid-scintillation counting. The half-life of caffeine in both serum and saliva was approximately 3 hr, with the concentration of caffeine in the saliva samples ranging from 65 to 85% of that found in the serum samples. The major metabolites found in serum and saliva were the dimethylxanthines. In the course of separating the urinary metabolites, our HPLC system partially resolved two unidentified polar metabolites arising from radiolabeled caffeine. The major component corresponded to 5-acetylamino-6-amino-3-methyluracil and in our subjects ranged from 7 to 35% of the administered dose. The other principal urinary metabolites were 1-methylxanthine at approximately 18% of the administered dose and 1-methyluric acid at 15%. The fecal samples contained approximately 5% of the dose, mainly as uric acid compounds which retained the 1-methyl group. In this study we accounted for approximately 90% of the administered radiolabeled dose and identified greater than 95% of the urinary radioactivity as specific metabolites

  9. Concentration compared with total urinary excretion of 11,17-DOA in cynomolgus monkey urine

    DEFF Research Database (Denmark)

    Hau, Jann; Royo, F

    2008-01-01

    Strees sensitive molecules exhibit great variation in concentration in the circulation and it may often be advantageous to quantify these in urine or feces rather than in serum or plasma. We advocate that all urine-or feces-should be collected, and that excretion of stress sensitive molecules sho...

  10. Determination of fluvoxamine maleate in human urine and human serum using alkaline KMnO4 -rhodamine B chemiluminescence.

    Science.gov (United States)

    Yang, Dongqin; He, Yanyan; Chen, Funan

    2017-09-01

    The flow-injection chemiluminescence (FI-CL) behavior of a gold nanocluster (Au NC)-enhanced rhodamine B-KMnO 4 system was studied under alkaline conditions for the first time. In the present study, the as-prepared bovine serum albumin-stabilized Au NCs showed excellent stability and reproducibility. The addition of trace levels of fluvoxamine maleate (Flu) led to an obvious decline in CL intensity in the rhodamine B-KMnO 4 -Au NCs system, which could be used for quantitative detection of Flu. Under optimized conditions, the proposed CL system exhibited a favorable analytical performance for Flu determination in the range 2 to 100 μg ml -1 . The detection limit for Flu measurement was 0.021 μg ml -1 . Moreover, this newly developed system revealed outstanding selectivity for Flu detection when compared with a multitude of other species, such as the usual ions, uric acid and a section of hydroxy compounds. Additionally, CL spectra, UV-visible spectroscopes and fluorescence spectra were measured in order to determine the possible reaction mechanism. This approach could be used to detect Flu in human urine and human serum samples with the desired recoveries and could have promising application under physiological conditions. Copyright © 2017 John Wiley & Sons, Ltd.

  11. A competitive immunoassay for ultrasensitive detection of Hg(2+) in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering.

    Science.gov (United States)

    She, Pei; Chu, Yanxin; Liu, Chunwei; Guo, Xun; Zhao, Kang; Li, Jianguo; Du, Haijing; Zhang, Xiang; Wang, Hong; Deng, Anping

    2016-02-04

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg(2+). This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg(2+) and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg(2+). The ICT was able to directly detect Hg(2+) without complexing due to the specific recognition of the mAb with Hg(2+). The IC50 and limit of detection (LOD) of the assay for Hg(2+) detection were 0.12 ng mL(-1) and 0.45 pg mL(-1), respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg(2+) were in range of 88.3-107.3% with the relative standard deviations (RSD) of 1.5-9.5% (n = 3). The proposed ICT was used for the detection of Hg(2+) in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg(2+) in environmental water samples and biological serum and urine samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. The proteome of human saliva

    Science.gov (United States)

    Griffin, Timothy J.

    2013-05-01

    Human saliva holds tremendous potential for transforming disease and health diagnostics given its richness of molecular information and non-invasive collection. Enumerating its molecular constituents is an important first step towards reaching this potential. Among the molecules in saliva, proteins and peptides arguably have the most value: they can directly indicate biochemical functions linked to a health condition/disease state, and they are attractive targets for biomarker assay development. However, cataloging and defining the human salivary proteome is challenging given the dynamic, chemically heterogeneous and complex nature of the system. In addition, the overall human saliva proteome is composed of several "sub-proteomes" which include: intact full length proteins, proteins carrying post-translational modifications (PTMs), low molecular weight peptides, and the metaproteome, derived from protein products from nonhuman organisms (e.g. microbes) present in the oral cavity. Presented here will be a summary of communal efforts to meet the challenge of characterizing the multifaceted saliva proteome, focusing on the use of mass spectrometry as the proteomic technology of choice. Implications of these efforts to characterize the salivary proteome in the context of disease diagnostics will also be discussed.

  13. Determination of acetone in saliva by reversed-phase liquid chromatography with fluorescence detection and the monitoring of diabetes mellitus patients with ketoacidosis.

    Science.gov (United States)

    Fujii, Shinya; Maeda, Toshio; Noge, Ichiro; Kitagawa, Yutaka; Todoroki, Kenichiro; Inoue, Koichi; Min, Jun Zhe; Toyo'oka, Toshimasa

    2014-03-20

    In diabetes mellitus (DM) patients with ketoacidosis, ketone bodies, i.e., acetone, acetoacetic acid (AA) and β-hydroxybutyric acid (HA), are increased in the blood and urine. Acetone is also excreted by breathing due to the spontaneous decomposition of AA. Thus, the increase in acetone has been considered as one of the biomarkers for the diagnosis of DM. However, the determination of acetone in one's breath is not recommended because of the sample handling difficulty. We measured acetone in saliva by reversed-phase liquid chromatography (LC) with fluorescence (FL) detection. The proposed method was applied to the determination of acetone in the saliva of healthy volunteers and DM patients with and without ketoacidosis. 3-Pentanone (I.S.) and DBD-H in acetonitrile were added to freshly collected saliva and reacted at room temperature for 20 min in the presence of trifluoroacetic acid. After the reaction, the solution was centrifuged at 10,000 × g and 4 °C for 5 min. The supernatant was separated by reversed-phase LC and the FL detected at 550 nm (excitation at 460 nm). The concentrations of acetone in the DM patients with ketoacidosis were significantly higher than those of the normal subjects and DM patients without ketoacidosis. Furthermore, the total contents of the ketone bodies in the blood correlated with acetone in the saliva of the DM patients. The concentrations of acetone in the saliva of an emergency patient also correlated with the ketone bodies in the blood at each sampling time. The proposed method using LC-FL seems to be useful for the determination of acetone in the saliva of DM patients with ketoacidosis. The method offers a new option for the diagnosis and monitoring of DM patients with ketoacidosis. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Associations between food consumption patterns and saliva composition: Specificities of eating difficulties children.

    Science.gov (United States)

    Morzel, Martine; Truntzer, Caroline; Neyraud, Eric; Brignot, Hélène; Ducoroy, Patrick; Lucchi, Géraldine; Canlet, Cécile; Gaillard, Ségolène; Nicod, Florian; Nicklaus, Sophie; Peretti, Noël; Feron, Gilles

    2017-05-01

    Identifying objective markers of diet would be beneficial to research fields such as nutritional epidemiology. As a preliminary study on the validity of using saliva for this purpose, and in order to explore the relationship between saliva and diet, we focused on clearly contrasted groups of children: children with eating difficulties (ED) receiving at least 50% of their energy intake through artificial nutrition vs healthy controls (C). Saliva of ED and C children was analyzed by various methods (targeted biochemical analyses, 2-D electrophoresis coupled to MS, 1 H NMR) and their diet was characterized using food frequency questionnaires, considering 148 food items grouped into 13 categories. Complete datasets were obtained for 16 ED and 16 C subjects (median age 4.7y and 5.0y, respectively) and the statistical link between salivary and dietary characteristics was studied by Multiple Factor Analysis (MFA). Overall, ED children showed as expected lower consumption frequency scores and higher food selectivity. The two groups of children differed in "diet/saliva" associations. Some distinctive salivary variables were common to both groups of children. For example, carbonic anhydrase 6 and the consumption frequency of biscuits & sweets and drinks were positively associated with the MFA axis 1 in C children, but oppositely associated in ED children. Specifically for ED children, abundant salivary proteins (cystatins, amylase, amylase fragments) and some metabolites (amino acids, galactose, lactate) correlated with axis 1, together with the consumption frequency of sauces & seasonings, bread & cereal products, ready-to-eat meals, fish, biscuits & sweets, drinks and potatoes. Specifically for C children, several proteins (serum albumin, haptoglobin, Igκ, apolipoprotein A-1, α-1 antitrypsin) correlated with axis 1, together with the consumption frequency of biscuits & sweets, milk & dairy products, drinks, fruit, meat and vegetables. This study demonstrates that the

  15. Relationship of flow rate, uric acid, peroxidase, and superoxide dismutase activity levels with complications in diabetic patients: can saliva be used to diagnose diabetes?

    Science.gov (United States)

    Zloczower, Moshe; Reznick, Abraham Z; Zouby, Rula Obeid; Nagler, Rafael M

    2007-06-01

    Can salivary free radicals and antioxidant parameters be useful in general diagnosis and evaluation of diabetes mellitus Type II (DM)? Serum and salivary redox state of 40 diabetes mellitus patients were examined and compared with 20 controls. The involvement of salivary gland in diabetes mellitus has been suggested based on salivary flow rate and compositional alterations. In addition, the redox state of saliva of diabetes mellitus patients is different than that of normoglycemic control human subjects. This observation unveils the opportunity to use noninvasive saliva-based diagnostics for diabetes mellitus patients.

  16. Evaluation of HPV-16 and HPV-18 specific antibody measurements in saliva collected in oral rinses and merocel® sponges.

    Science.gov (United States)

    Parker, Katherine H; Kemp, Troy J; Pan, Yuanji; Yang, Zhen; Giuliano, Anna R; Pinto, Ligia A

    2018-05-03

    Current Human papillomavirus (HPV) L1 VLP vaccines protect against HPV-16 and HPV-18-associated cancers, in females and males. Although correlates of protection have not been identified, HPV-specific antibodies at sites of infection are thought to be the main mechanism of protection afforded by vaccination. Oral sampling has gained increased attention as a potential alternative to serum in monitoring immunity to vaccination and understanding local immunity in oral cancers. Serum was collected via venipuncture, and saliva was collected via oral rinses and Merocel® sponges from healthy volunteers: 16 unvaccinated females, 6 females (ages 24-41) and 6 mid-adult aged males (ages 27-45) recipients of three doses of the HPV-16/18/6/11 vaccine (Gardasil®). Mid-adult male vaccine trial participants were compared to female participants. Samples were tested for anti-HPV-16 and anti-HPV-18 immunoglobulin G levels by an L1 virus-like particle-based enzyme-linked immunosorbent assay (ELISA). All vaccinated participants had detectable serum anti-HPV-16 and anti-HPV-18 antibodies. Optimal standard concentration range and sample serial dilutions for oral rinses were determined. The standard curve was not affected by the type of solution examined. Reproducibility of HPV-16 and HPV-18 antibody titers in mouthwash (overall CV  0.9) was observed for sera spiked controls in both solutions. HPV-16 and HPV-18 specific antibodies were detectable in saliva from vaccine recipients, both in mouthwash and in Merocel® sponges but levels were several logs lower than those in serum. This study confirms the application of HPV-16 and HPV-18 ELISAs currently used in sero-epidemiological studies of immunogenicity of HPV vaccines for use with oral samples. Oral samples may be a useful resource for the detection of HPV-16 and HPV-18-specific antibodies in saliva following vaccination. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Is parotid saliva sterile on entry to the oral cavity?

    DEFF Research Database (Denmark)

    Schrøder, Stine A; Bardow, Allan; Eickhardt-Dalbøge, Steffen

    2017-01-01

    CONCLUSION: The present study indicates that parotid saliva is sterile on entry to the oral cavity. OBJECTIVES: The objective was to investigate if parotid saliva is sterile on entry to the oral cavity and, thus, prior to contamination by oral bacteria. METHOD: Forty healthy volunteers were...... included in sterile parotid saliva collection. Parotid saliva was collected using a sterile Lashley cup, placed over the papilla of the Stensen´s duct, as well as sterile tubes and syringes for collection. All collections were followed by collection of a positive control sample where some of the sterile...... obtained parotid saliva had been exposed to the contralateral mucosal membranes. All samples parotid saliva, as well as the positive controls, were cultivated, and 10 randomly selected parotid saliva samples underwent polymerase chain reaction (PCR) analyses. RESULTS: In 33 of 40 parotid saliva samples...

  18. Human Saliva Collection Devices for Proteomics: An Update

    Directory of Open Access Journals (Sweden)

    Zohaib Khurshid

    2016-06-01

    Full Text Available There has been a rapid growth in the interest and adaptation of saliva as a diagnostic specimen over the last decade, and in the last few years in particular, there have been major developments involving the application of saliva as a clinically relevant specimen. Saliva provides a “window” into the oral and systemic health of an individual, and like other bodily fluids, saliva can be analyzed and studied to diagnose diseases. With the advent of new, more sensitive technologies to detect smaller concentrations of analytes in saliva relative to blood levels, there have been a number of critical developments in the field that we will describe. In particular, recent advances in standardized saliva collection devices that were not available three to four years ago, have made it easy for safe, simple, and non-invasive collection of samples to be carried out from patients. With the availability of these new technologies, we believe that in the next decade salivary proteomics will make it possible to predict and diagnose oral as well as systemic diseases, cancer, and infectious diseases, among others. The aim of this article is to review recent developments and advances in the area of saliva specimen collection devices and applications that will advance the field of proteomics.

  19. Saliva as a diagnostic fluid: literature review

    OpenAIRE

    Martí Álamo, Silvia; Mancheño Franch, Aisha; Marzal Gamarra, Cristina

    2012-01-01

    There is a growing interest in diagnosis based on the analysis of saliva. This is a simple, non-invasive method of obtaining oral samples which is safe for both the health worker and the patient, not to mention allowing for simple and cost-efficient storage. The majority of studies use general saliva samples in their entirety, complex fluids containing both local and systemic sources and whose composition corresponds to that of the blood. General saliva contains a considerable ...

  20. Direct Analysis of Amphetamine Stimulants in a Whole Urine Sample by Atmospheric Solids Analysis Probe Tandem Mass Spectrometry

    Science.gov (United States)

    Crevelin, Eduardo J.; Salami, Fernanda H.; Alves, Marcela N. R.; De Martinis, Bruno S.; Crotti, Antônio E. M.; Moraes, Luiz A. B.

    2016-05-01

    Amphetamine-type stimulants (ATS) are among illicit stimulant drugs that are most often used worldwide. A major challenge is to develop a fast and efficient methodology involving minimal sample preparation to analyze ATS in biological fluids. In this study, a urine pool solution containing amphetamine, methamphetamine, ephedrine, sibutramine, and fenfluramine at concentrations ranging from 0.5 pg/mL to 100 ng/mL was prepared and analyzed by atmospheric solids analysis probe tandem mass spectrometry (ASAP-MS/MS) and multiple reaction monitoring (MRM). A urine sample and saliva collected from a volunteer contributor (V1) were also analyzed. The limit of detection of the tested compounds ranged between 0.002 and 0.4 ng/mL in urine samples; the signal-to-noise ratio was 5. These results demonstrated that the ASAP-MS/MS methodology is applicable for the fast detection of ATS in urine samples with great sensitivity and specificity, without the need for cleanup, preconcentration, or chromatographic separation. Thus ASAP-MS/MS could potentially be used in clinical and forensic toxicology applications.

  1. [Concentration of calcium ions in the saliva and the value of the pH of the saliva in female and male smokers].

    Science.gov (United States)

    Nakonieczna-Rudnicka, Marta; Bachanek, Teresa; Rogowska, Wanda

    2009-01-01

    Dental decay is a pathological process of extrasomatic origin which leads to demineralization and proteolytic degradation of hard surfaces of a tooth susceptible to this disease. Saliva composition, including calcium ion concentration and its pH value, is of importance in the development of the carious process. Tobacco smoke contains toxic compounds which negatively influence oral health. The aim of the study was evaluation of the selected saliva components: protein concentration, Ca2+ concentration, pH value both in male and female smokers. The investigated group included 65 patients reporting for the treatment to the Department of Conservative Dentistry of Medical University in Lublin. In the investigated group male smokers constituted 15.38%, female smokers--20.00%, male nicotine abstinents 21.54% and female nicotine abstinent 43.08%. The study included both survey examinations of patients and biochemical examinations of the saliva. Mixed, non-stimulated saliva was used as a material for biochemical examinations. Ca2+ concentration and pH of the saliva were assayed with the use of Rapidlab 348 analyzer. Protein in the saliva was assayed with calorimetric method according to Lowry. Saliva was collected from smokers 10-120 minutes after smoking of several cigarettes. It was stated that Ca2+ and protein concentration as well as pH of the saliva were not correlated with sex and cigarette smoking or non-smoking.

  2. Efek Pengunyahan Permen Karet Gula dan Xylitol terhadap Status Saliva

    Directory of Open Access Journals (Sweden)

    Lisna Kurnia Rezky

    2016-11-01

    Full Text Available Latar belakang. Rongga mulut sebagai pintu masuk makanan ke dalam tubuh selalu dibasahi oleh saliva setiap harinya. Saat ini banyak produk permen karet yang beredar di masyarakat yang mengandung gula dan xylitol. Banyak orang yang gemar mengunyah permen karet dengan kurang memperhatikan komposisinya baik yang mengandung gula ataupun xylitol sehingga kurang mengetahui efek masing-masing jenis permen karet tersebut terhadap kesehatan rongga mulut. Tujuan. Penelitian ini bertujuan untuk mengetahui efek pengunyahan permen karet gula dengan permen karet xylitol terhadap status saliva yang terdiri dari volume, pH, dan viskositas saliva. Metode penelitian. Subjek penelitian berjumlah 30 orang dibagi menjadi 3 kelompok masing-masing 10 orang, terdiri dari kelompok mengunyah permen karet gula, xylitol, dan kontrol dengan mengunyah apel. Pengambilan saliva dilakukan pagi hari dan siang hari. Subjek mengunyah 2 butir permen karet dan tidak diperbolehkan untuk makan dan minum 1 jam sebelum mengunyah. Subjek diinstruksikan meludah ke dalam pot saliva selama 10 menit dalam interval setiap 1 menit. Pengukuran volume saliva menggunakan pipet volume, pH saliva dengan menggunakan pH meter, dan viskositas saliva dengan menggunakan viskometer Ostwald hari ke-1 dan ke-4. Analisis data dengan uji statistik Mann-Whitney. Hasil. penelitian menunjukkan adanya peningkatan bermakna volume dan viskositas saliva pada pengunyahan permen karet xylitol dan gula. Derajat keasaman (pH saliva menurun setelah mengunyah permen karet gula sedangkan pada perm en karet xylitol relatif stabil. Disimpulkan bahwa permen karet xylitollebih baik untuk kestabilan status saliva dibandingkan permen karet gula.

  3. Disposable Collection Kit for Rapid and Reliable Collection of Saliva

    OpenAIRE

    Yamaguchi, Masaki; Tezuka, Yuki; Takeda, Kazunori; Shetty, Vivek

    2015-01-01

    Objectives To describe and evaluate disposable saliva collection kit for rapid, reliable, and reproducible collection of saliva samples. Methods The saliva collection kit comprised of a saliva absorbent swab and an extractor unit was used to retrieve whole saliva samples from 10 subjects. The accuracy and precision of the extracted volumes (3, 10, and 30 ?l) were compared to similar volumes drawn from control samples obtained by passive drool. Additionally, the impact of kit collection method...

  4. Evaluation of calcium, phosphorus and potassium in saliva and their relationship to blood biochemical factors in hemodialysis patients

    Directory of Open Access Journals (Sweden)

    Javad Hashemi

    2017-04-01

    Full Text Available Background: Nowadays, chronic kidney disease (CKD is known as an epidemic disease all around the world. Chronic kidney disease considered as a serious health problem with numerous side effects, including complications progressive in reducing glomerular filtration rate (GFR, imbalances in the homeostasis of the body and decreased quality of life and finally an increase in mortality due to cardiovascular problems. End-stage renal disease leads to hypocalcemia and hyperphosphatemia, that as a result of, parathyroid hormone (PTH will increased that secondary hyperparathyroidism will occurred eventually. So it is essential to routine examination of electrolytes in these patients. The current study have been done to determine the electrolytes in saliva as a non-invasive sample in hemodialysis patients in order to the saliva to be presented as an appropriate samples for clinical laboratories. Methods: In the present case-control study that has been performed at Imam Ali Hospital, Bojnord, North Khorasan Province, Iran, in the summer of 2016, 44 hemodialysis patients and 44 aged, gender and body mass index (BMI matched healthy controls were selected and then their cell count, Hb, HCT, iron, ferritin, total iron binding capacity (TIBC, glucose, CRP, triglycerides, cholesterol, urea, creatinine, calcium, phosphorus, potassium and PTH were measured. Results: Calcium and phosphorus were higher in hemodialysis patients in comparison to the control group. Furthermore, there are not any significant relationship between levels of calcium, phosphorus and potassium in both serum and saliva samples. In addition, we observed the positive relationship between PTH in serum as well as phosphorus and potassium in the saliva. Conclusion: The findings of current study have been shown that salivary levels of calcium and phosphorus in hemodialysis patients is higher than healthy people, therefor could be a non- invasive suitable marker for diagnosis. In addition, blood PTH

  5. CYP2D6 Phenotyping Using Urine, Plasma, and Saliva Metabolic Ratios to Assess the Impact of CYP2D6∗10 on Interindividual Variation in a Chinese Population

    Directory of Open Access Journals (Sweden)

    Pei Hu

    2017-05-01

    Full Text Available Purpose: Asian populations have around 40–60% frequency of reduced function allele CYP2D6∗10 compared to 1–2% in Caucasian populations. The wide range of CYP2D6 enzyme activities in subjects with the CYP2D6∗10 variant is a big concern for clinical practice. The quantitative analysis measuring the impact of CYP2D6 enzyme activity as a result of one CYP2D6∗10 allele or two CYP2D6∗10 alleles has not been reported in large Asian populations.Methods: A total of 421 healthy Chinese subjects were genotyped for CYP2D6 by polymerase chain reaction and direct DNA sequencing. A total of 235 subjects with CYP2D6∗1/∗1 (n = 22, CYP2D6∗1/∗10 (n = 93, CYP2D6∗10/∗10 (n = 85, and CYP2D6∗5/∗10 (n = 35 were phenotyped for CYP2D6 using dextromethorphan as the probe drug. Metabolic ratios (MR were calculated as the ratio of parent drug to metabolite in 0–3 h urine, 3 h plasma, and 3 h saliva for each sample type.Results: The urinary, plasma, or salivary MRs increased successively in subjects with CYP2D6∗1/∗1, ∗1/∗10, ∗10/∗10, and ∗5/∗10 (all P < 0.001. In the normal metabolizer group, homozygous CYP2D6∗10/∗10 decreased the CYP2D6 enzyme activity further than heterozygous CYP2D6∗1/∗10. Urinary, plasma, and salivary MRs were highly correlated.Conclusion: The normal metabolizer group calls for a more detailed classification. The activity score system could more accurately predict enzyme activity than by grouping a number of genotypes into a single phenotype group. Single-point plasma samples and saliva samples could be used as alternative phenotyping methods for clinical convenience.

  6. Saliva transit in patients with gastroesophageal reflux disease.

    Science.gov (United States)

    Cassiani, R A; Mota, G A; Aprile, L R O; Dantas, R O

    2015-10-01

    Saliva is an important factor in the neutralization of the acidity of the refluxed material that comes from the stomach to the esophagus. The impairment of saliva transit from oral cavity to distal esophagus may be one of the causes of esophagitis and symptoms in gastroesophageal reflux disease (GERD). With the scintigraphic method, the transit of 2 mL of artificial saliva was measured in 30 patients with GERD and 26 controls. The patients with GERD had symptoms of heartburn and acid regurgitation, a 24-hour pH monitoring with more than 4.2% of the time with pH below four, 26 with erosive esophagitis, and four with non-erosive reflux disease. Fourteen had mild dysphagia for solid foods. Twenty-one patients had normal esophageal manometry, and nine had ineffective esophageal motility. They were 15 men and 15 women, aged 21-61 years, mean 39 years. The control group had 14 men and 12 women, aged 19-61 years, mean 35 years. The subjects swallowed in the sitting and supine position 2 mL of artificial saliva labeled with 18 MBq of (99m) Technetium phytate. The time of saliva transit was measured from oral cavity to esophageal-gastric transition, from proximal esophagus to esophageal-gastric transition, and the transit through proximal, middle, and distal esophageal body. There was no difference between patients and controls in the time for saliva to go from oral cavity to esophageal-gastric transition, and from proximal esophagus to esophageal-gastric transition, in the sitting and supine positions. In distal esophagus in the sitting position, the saliva transit duration was shorter in patients with GERD (3.0 ± 0.8 seconds) than in controls (7.6 ± 1.7 seconds, P = 0.03). In conclusion, the saliva transit from oral cavity to the esophageal-gastric transition in patients with GERD has the same duration than in controls. Saliva transit through the distal esophageal body is faster in patients with GERD than controls. © 2014 International Society for Diseases of the

  7. Identifying Urinary and Serum Exosome Biomarkers for Radiation Exposure Using a Data Dependent Acquisition and SWATH-MS Combined Workflow

    International Nuclear Information System (INIS)

    Kulkarni, Shilpa; Koller, Antonius; Mani, Kartik M.; Wen, Ruofeng; Alfieri, Alan; Saha, Subhrajit; Wang, Jian; Patel, Purvi; Bandeira, Nuno; Guha, Chandan

    2016-01-01

    Purpose: Early and accurate assessment of radiation injury by radiation-responsive biomarkers is critical for triage and early intervention. Biofluids such as urine and serum are convenient for such analysis. Recent research has also suggested that exosomes are a reliable source of biomarkers in disease progression. In the present study, we analyzed total urine proteome and exosomes isolated from urine or serum for potential biomarkers of acute and persistent radiation injury in mice exposed to lethal whole body irradiation (WBI). Methods and Materials: For feasibility studies, the mice were irradiated at 10.4 Gy WBI, and urine and serum samples were collected 24 and 72 hours after irradiation. Exosomes were isolated and analyzed using liquid chromatography mass spectrometry/mass spectrometry-based workflow for radiation exposure signatures. A data dependent acquisition and SWATH-MS combined workflow approach was used to identify significantly exosome biomarkers indicative of acute or persistent radiation-induced responses. For the validation studies, mice were exposed to 3, 6, 8, or 10 Gy WBI, and samples were analyzed for comparison. Results: A comparison between total urine proteomics and urine exosome proteomics demonstrated that exosome proteomic analysis was superior in identifying radiation signatures. Feasibility studies identified 23 biomarkers from urine and 24 biomarkers from serum exosomes after WBI. Urinary exosome signatures identified different physiological parameters than the ones obtained in serum exosomes. Exosome signatures from urine indicated injury to the liver, gastrointestinal, and genitourinary tracts. In contrast, serum showed vascular injuries and acute inflammation in response to radiation. Selected urinary exosomal biomarkers also showed changes at lower radiation doses in validation studies. Conclusions: Exosome proteomics revealed radiation- and time-dependent protein signatures after WBI. A total of 47 differentially secreted

  8. Identifying Urinary and Serum Exosome Biomarkers for Radiation Exposure Using a Data Dependent Acquisition and SWATH-MS Combined Workflow

    Energy Technology Data Exchange (ETDEWEB)

    Kulkarni, Shilpa [Department of Radiation Oncology, Albert Einstein College of Medicine, Bronx, New York (United States); Koller, Antonius [Proteomics Center, Stony Brook University School of Medicine, Stony Brook, New York (United States); Proteomics Shared Resource, Herbert Irving Comprehensive Cancer Center, New York, New York (United States); Mani, Kartik M. [Department of Radiation Oncology, Albert Einstein College of Medicine, Bronx, New York (United States); Wen, Ruofeng [Department of Applied Mathematics and Statistics, Stony Brook University, Stony Brook, New York (United States); Alfieri, Alan; Saha, Subhrajit [Department of Radiation Oncology, Albert Einstein College of Medicine, Bronx, New York (United States); Wang, Jian [Center for Computational Mass Spectrometry, University of California, San Diego, California (United States); Department of Computer Science and Engineering, University of California, San Diego, California (United States); Patel, Purvi [Proteomics Shared Resource, Herbert Irving Comprehensive Cancer Center, New York, New York (United States); Department of Pharmacological Sciences, Stony Brook University, Stony Brook, New York (United States); Bandeira, Nuno [Center for Computational Mass Spectrometry, University of California, San Diego, California (United States); Department of Computer Science and Engineering, University of California, San Diego, California (United States); Skaggs School of Pharmacy and Pharmaceutical Sciences, University of California, San Diego, California (United States); Guha, Chandan, E-mail: cguha@montefiore.org [Department of Radiation Oncology, Albert Einstein College of Medicine, Bronx, New York (United States); and others

    2016-11-01

    Purpose: Early and accurate assessment of radiation injury by radiation-responsive biomarkers is critical for triage and early intervention. Biofluids such as urine and serum are convenient for such analysis. Recent research has also suggested that exosomes are a reliable source of biomarkers in disease progression. In the present study, we analyzed total urine proteome and exosomes isolated from urine or serum for potential biomarkers of acute and persistent radiation injury in mice exposed to lethal whole body irradiation (WBI). Methods and Materials: For feasibility studies, the mice were irradiated at 10.4 Gy WBI, and urine and serum samples were collected 24 and 72 hours after irradiation. Exosomes were isolated and analyzed using liquid chromatography mass spectrometry/mass spectrometry-based workflow for radiation exposure signatures. A data dependent acquisition and SWATH-MS combined workflow approach was used to identify significantly exosome biomarkers indicative of acute or persistent radiation-induced responses. For the validation studies, mice were exposed to 3, 6, 8, or 10 Gy WBI, and samples were analyzed for comparison. Results: A comparison between total urine proteomics and urine exosome proteomics demonstrated that exosome proteomic analysis was superior in identifying radiation signatures. Feasibility studies identified 23 biomarkers from urine and 24 biomarkers from serum exosomes after WBI. Urinary exosome signatures identified different physiological parameters than the ones obtained in serum exosomes. Exosome signatures from urine indicated injury to the liver, gastrointestinal, and genitourinary tracts. In contrast, serum showed vascular injuries and acute inflammation in response to radiation. Selected urinary exosomal biomarkers also showed changes at lower radiation doses in validation studies. Conclusions: Exosome proteomics revealed radiation- and time-dependent protein signatures after WBI. A total of 47 differentially secreted

  9. Saliva: Physiology and Diagnostic Potential in Health and Disease

    Directory of Open Access Journals (Sweden)

    Sebastien J. C. Farnaud

    2010-01-01

    Full Text Available Saliva has been described as the mirror of the body. In a world of soaring healthcare costs and an environment where rapid diagnosis may be critical to a positive patient outcome, saliva is emerging as a viable alternative to blood sampling. In this review, we discuss the composition and various physiological roles of saliva in the oral cavity, including soft tissue protection, antimicrobial activities, and oral tissue repair. We then explore saliva as a diagnostic marker of local oral disease and focus particularly on oral cancers. The cancer theme continues when we focus on systemic disease diagnosis from salivary biomarkers. Communicable disease is the focus of the next section where we review the literature relating to the direct and indirect detection of pathogenic infections from human saliva. Finally, we discuss hormones involved in appetite regulation and whether saliva is a viable alternative to blood in order to monitor hormones that are involved in satiety.

  10. The Association Between Urine Output, Creatinine Elevation, and Death.

    Science.gov (United States)

    Engoren, Milo; Maile, Michael D; Heung, Michael; Jewell, Elizabeth S; Vahabzadeh, Christie; Haft, Jonathan W; Kheterpal, Sachin

    2017-04-01

    Acute kidney injury can be defined by a fall in urine output, and urine output criteria may be more sensitive in identifying acute kidney injury than traditional serum creatinine criteria. However, as pointed out in the Kidney Disease Improving Global Outcome guidelines, the association of urine output with subsequent creatinine elevations and death is poorly characterized. The purpose of this study was to determine what degrees of reduced urine output are associated with subsequent creatinine elevation and death. This was a retrospective cohort study of adult patients (age ≥18 years) cared for in a cardiovascular intensive care unit after undergoing cardiac operations in a tertiary care university medical center. All adult patients who underwent cardiac operations and were not receiving dialysis preoperatively were studied. The development of acute kidney injury was defined as an increase in creatinine of more than 0.3 mg/dL or by more than 50% above baseline by postoperative day 3. Acute kidney injury developed in 1,061 of 4,195 patients (25%). Urine output had moderate discrimination in predicting subsequent acute kidney injury (C statistic = .637 ± .054). Lower urine output and longer duration of low urine output were associated with greater odds of developing acute kidney injury and death. We found that there is similar accuracy in using urine output corrected for actual, ideal, or adjusted weight to discriminate future acute kidney injury by creatinine elevation and recommend using actual weight for its simplicity. We also found that low urine output is associated with subsequent acute kidney injury and that the association is greater for lower urine output and for low urine output of longer durations. Low urine output (creatinine elevation, is independently associated with mortality. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  11. HEPATITIS B VIRUS DNA IN SALIVA FROM CHILDREN WITH CHRONIC HEPATITIS B INFECTION IMPLICATIONS FOR SALIVA AS A POTENTIAL MODE OF HORIZONTAL TRANSMISSION

    NARCIS (Netherlands)

    Heiberg, Ida Louise; Hoegh, Mette; Ladelund, Steen; Niesters, Hubert G. M.; Hogh, Birthe

    2010-01-01

    To explore the mechanism of horizontal transmission of hepatitis B virus (HBV) among children, we investigated the quantitative relationship between HBV in saliva and blood from 46 children with chronic hepatitis B. We found high levels of HBV DNA in saliva of HBeAg (+) children, suggesting saliva

  12. Hepatitis B virus DNA in saliva from children with chronic hepatitis B infection: implications for saliva as a potential mode of horizontal transmission

    DEFF Research Database (Denmark)

    Heiberg, Ida Louise; Hoegh, Mette; Ladelund, Steen

    2010-01-01

    To explore the mechanism of horizontal transmission of hepatitis B virus (HBV) among children, we investigated the quantitative relationship between HBV in saliva and blood from 46 children with chronic hepatitis B. We found high levels of HBV DNA in saliva of HBeAg (+) children, suggesting saliva...

  13. Anti-inflammatory and antinociceptive activities of Rhipicephalus microplus saliva

    Directory of Open Access Journals (Sweden)

    D F Buccini

    2018-01-01

    Full Text Available Objective: To evaluate the antinociceptive and anti-inflammatory activities and the toxic effects of Rhipicephalus microplus saliva for elucidating the modulation mechanism between arthropod saliva and host. Methods: For saliva collection, engorged ticks were obtained from a controlled bovine infestation and collected by natural fall. The ticks were fixed and injected pilocarpine 0.2% for induction of salivation. Saliva was collected, lyophilized and stored at - 80 °C. Cytotoxic activity was assessed by the hemolysis method (25, 50, 100, 200 and 300 μ g/mL and MTT cell viability assay (2.5, 5, 10, 20 and 40 μ g/mL for 24, 48 and 72 h. Anti-inflammatory activity was evaluated using the method of neutrophil migration to the peritoneal cavity of mice at doses of 10, 15 and 20 mg/kg; antinociceptive activity was assessed using the acetic acid-induced writhing test, and formalin-induced paw-licking in mice at dose of 15 mg/kg. Results: Saliva did not cause erythrocytes hemolysis at any concentration tested, as well as did not decrease cell viability in the MTT assay. Saliva inhibited neutrophil migration by 87% and 73% at doses of 15 and 20 mg/kg, respectively. In the nociceptive tests, saliva presented analgesic activity of 69.96% in the abdominal writhing test, and of 84.41% in the formalin test. Conclusions: The study proves that Rhipicephalus microplus saliva has significant in vivo anti-inflammatory and antinociceptive activities. The data presented herein support the development of further studies to elucidate the active principles of Rhipicephalus microplus saliva and its mechanism of action and, in future, to develop novel anti-inflammatory and analgesic drugs.

  14. Estimate of dietary phosphorus intake using 24-h urine collection

    Science.gov (United States)

    Morimoto, Yuuka; Sakuma, Masae; Ohta, Hiroyuki; Suzuki, Akitsu; Matsushita, Asami; Umeda, Minako; Ishikawa, Makoto; Taketani, Yutaka; Takeda, Eiji; Arai, Hidekazu

    2014-01-01

    Increases in serum phosphorus levels and dietary phosphorus intake induces vascular calcification, arterial sclerosis and cardiovascular diseases. Limiting phosphorus intake is advisable, however, no assessment methods are capable of estimating dietary phosphorus intake. We hypothesized that urinary phosphorus excretion can be translated into estimation of dietary phosphorus intake, and we evaluated whether a 24-h urine collection method could estimate dietary phosphorus intake. Thirty two healthy subjects were recruited for this study. Subjects collected urine samples over 24 h and weighed dietary records. We calculated dietary protein intake and phosphorus intake from dietary records and urine collection, and investigated associations between the two methods in estimating protein and phosphorus intake. Significant positive correlations were observed between dietary records and UC for protein and phosphorus intake. The average intakes determined from dietary records were significantly higher than from urine collection for both protein and phosphorus. There was a significant positive correlation between both the phosphorus and protein difference in dietary records and urine collection. The phosphorus-protein ratio in urine collection was significantly higher than in dietary records. Our data indicated that the 24-h urine collection method can estimate the amount of dietary phosphorus intake, and the results were superior to estimation by weighed dietary record. PMID:25120281

  15. Dynamic changes in saliva after acute mental stress

    Science.gov (United States)

    Naumova, Ella A.; Sandulescu, Tudor; Bochnig, Clemens; Khatib, Philipp Al; Lee, Wing-Kee; Zimmer, Stefan; Arnold, Wolfgang H.

    2014-01-01

    Stress-related variations of fluoride concentration in supernatant saliva and salivary sediment, salivary cortisol, total protein and pH after acute mental stress were assessed. The hypothesis was that stress reactions have no influence on these parameters. Thirty-four male students were distributed into two groups: first received the stress exposure followed by the same protocol two weeks later but without stress exposure, second underwent the protocol without stress exposure followed by the stress exposure two weeks later. The stressor was a public speech followed by tooth brushing. Saliva was collected before, immediately after stress induction and immediately, at 10, 30 and 120 min. after tooth brushing. Cortisol concentrations, total protein, intraoral pH, and fluoride content in saliva were measured. The data were analyzed statistically. Salivary sediment was ca 4.33% by weight of whole unstimulated saliva. Fluoride bioavailability was higher in salivary sediment than in supernatant saliva. The weight and fluoride concentration was not altered during 2 hours after stress exposure. After a public speech, the salivary cortisol concentration significantly increased after 20 minutes compared to the baseline. The salivary protein concentration and pH also increased. Public speaking influences protein concentration and salivary pH but does not alter the fluoride concentration of saliva. PMID:24811301

  16. HEMATOLOGY, SERUM BIOCHEMISTRY, AND URINALYSIS VALUES IN THE ADULT GIANT PANDA ( AILUROPODA MELANOLEUCA).

    Science.gov (United States)

    Burrell, Caitlin; Zhang, Hemin; Li, Desheng; Wang, Chengdong; Li, Caiwu; Aitken-Palmer, Copper

    2017-12-01

    The giant panda ( Ailuropoda melanoleuca) is a high-profile threatened species with individuals in captivity worldwide. As a result of advances in captive animal management and veterinary medicine, the ex situ giant panda population is aging, and improved understanding of age-related changes is necessary. Urine and blood samples were collected in April and July 2015 and analyzed for complete blood count, serum biochemistry, and biochemical and microscopic urine analysis for all individuals sampled ( n = 7, 7-16 yr of age) from giant panda housed at the China Research and Conservation Centre for the Giant Panda in Bifengxia, Sichuan Province, China. Hematology and serum biochemistry values were similar to those previously reported for giant panda aged 2-20 yr and to Species360 (formerly International Species Information System) values. Urine was overall dilute (urine specific gravity range: 1.001-1.021), acellular, and acidic (pH range: 6-7). This is the first report of hematologic and serum biochemistry, with associated urinalysis values, in the giant panda aged 7-16 yr.

  17. Can salivary creatinine and urea levels be used to diagnose chronic kidney disease in children as accurately as serum creatinine and urea levels? A case-control study.

    Science.gov (United States)

    Renda, Rahime

    2017-11-01

    Children with chronic kidney disease (CKD) develop many metabolic changes in blood that often necessitate frequent biochemical analysis. Serum analysis is an invasive and painful procedure. It would be highly beneficial if a noninvasive alternative process to serum analysis in children were identified. Saliva can be collected noninvasively, repeatedly, and without the use of healthcare personnel. The aims of this study were to compare serum and salivary urea and creatinine levels in children with CKD and healthy controls, and to determine if salivary creatinine and urea levels can be used to diagnose CKD in children as accurately as serum creatinine and urea levels. This case-control study included 35 children with CKD and 28 healthy children as controls. Saliva and blood samples were collected for measurement of urea and creatinine levels. The urea and creatinine levels in serum and saliva in the CKD and control groups were compared using the independent samples Mann-Whitney U test. Correlations between the serum and salivary urea and creatinine levels were determined using Pearson's correlation coefficient. Receiver operating characteristic analysis was used to assess the diagnostic performance of salivary creatinine and cutoff values were identified. In the CKD group, the mean salivary creatinine level was 0.45 mg/dL and the mean salivary urea level was 0.11 mg/dL, versus 28.83 mg/dL and 21.78 mg/dL, respectively, in the control group. Stage 4 and 5 CKD patients had a mean salivary urea level of 31.35 mg/dL, as compared to 17.78 mg/dL in the control group. Serum urea and creatinine, and salivary creatinine were significantly higher in the CKD patients (regardless of disease stage) than in the controls (p creatinine. The area under the curve for salivary creatinine was 0.805. The cutoff value for salivary creatinine was 0.125 mg/dL, with a sensitivity of 82.9% and specificity of 78.6%. Based on the positive correlation between the serum and saliva

  18. DNA methylation analysis from saliva samples for epidemiological studies.

    Science.gov (United States)

    Nishitani, Shota; Parets, Sasha E; Haas, Brian W; Smith, Alicia K

    2018-06-18

    Saliva is a non-invasive, easily accessible tissue, which is regularly collected in large epidemiological studies to examine genetic questions. Recently, it is becoming more common to use saliva to assess DNA methylation. However, DNA extracted from saliva is a mixture of both bacterial and human DNA derived from epithelial and immune cells in the mouth. Thus, there are unique challenges to using salivary DNA in methylation studies that can influence data quality. This study assesses: (1) quantification of human DNA after extraction; (2) delineation of human and bacterial DNA; (3) bisulfite conversion (BSC); (4) quantification of BSC DNA; (5) PCR amplification of BSC DNA from saliva and; (6) quantitation of DNA methylation with a targeted assay. The framework proposed will allow saliva samples to be more widely used in targeted epigenetic studies.

  19. Binding of corroded ions to human saliva.

    Science.gov (United States)

    Mueller, H J

    1985-05-01

    Employing equilibrium dialysis, the binding abilities of Cu, Al, Co and Cr ions from corroded Cu-Al and Co-Cr dental casting alloys towards human saliva and two of its gel chromatographic fractions were determined. Results indicate that both Cu and Co bind to human saliva i.e. 0.045 and 0.027 mg/mg protein, respectively. Besides possessing the largest binding ability, Cu also possessed the largest binding capacity. The saturation of Cu binding was not reached up to the limit of 0.35 mg protein/ml employed in the tests, while Co reached full saturation at about 0.2 mg protein/ml. Chromium showed absolutely no binding to human saliva while Al ions did not pass through the dialysis membranes. Compared to the binding with solutions that were synthetically made up to contain added salivary-type proteins, it is shown that the binding to human saliva is about 1 order of magnitude larger, at least for Cu ions.

  20. Hepatitis B virus DNA in saliva from children with chronic hepatitis B infection: implications for saliva as a potential mode of horizontal transmission

    DEFF Research Database (Denmark)

    Heiberg, Ida Louise; Hoegh, Mette; Ladelund, Steen

    2010-01-01

    To explore the mechanism of horizontal transmission of hepatitis B virus (HBV) among children, we investigated the quantitative relationship between HBV in saliva and blood from 46 children with chronic hepatitis B. We found high levels of HBV DNA in saliva of HBeAg (+) children, suggesting saliva...... as a vehicle for horizontal transmission of HBV among children....

  1. Value of Tropheryma whipplei quantitative polymerase chain reaction assay for the diagnosis of Whipple disease: usefulness of saliva and stool specimens for first-line screening.

    Science.gov (United States)

    Fenollar, Florence; Laouira, Sonia; Lepidi, Hubert; Rolain, Jean-Marc; Raoult, Didier

    2008-09-01

    Whipple disease (WD) is a chronic infectious disease caused by Tropheryma whipplei. WD DNA has been found in stool and saliva specimens from patients and asymptomatic carriers. A total of 4418 samples that were sent to our center for determination of WD were tested by a T. whipplei-specific quantitative polymerase chain reaction (PCR) based on repetitive sequences. Definite WD was diagnosed in 71 patients, including 55 patients with classic WD (defined by positive results of periodic acid-Schiff staining and/or specific immunohistochemistry of small-bowel biopsy specimens) and 16 patients with localized WD (including patients with endocarditis, neurologic infection, and uveitis). Of the persons without WD, 2.3% had stool specimens positive for T. whipplei by PCR and 0.2% had saliva specimens positive for T. whipplei by PCR. Diagnosis of WD was likely in patients with positive results of both PCR of saliva specimens and PCR of stool specimens (positive predictive value, 95.2%). When the bacterial load was >10(4) colony-forming units per g of stool, the positive predictive value was 100%. A negative result of PCR of a saliva or stool specimen had a negative predictive value of 99.2% for classic WD. For localized WD, positive results of both PCR of saliva specimens and PCR of stool specimens had a sensitivity of 58% (compared with 94% for classic WD). The positive predictive value of testing of blood, cerebrospinal fluid, and urine specimens was 100% for each, and the positive predictive value for testing of duodenal biopsy specimens was 97.5%. T. whipplei-specific quantitative PCR of saliva and stool specimens should be performed as first-line noninvasive screening for WD. When the results for both types of specimens are positive, diagnosis of classic WD should be highly suspected, especially if a high bacterial load is detected. Because PCR of saliva and stool specimens lacks sensitivity for determination of localized WD, invasive samples should be tested on the

  2. Facilitated saliva secretion and reduced oral inflammation by a novel artificial saliva system in the treatment of salivary hypofunction

    Directory of Open Access Journals (Sweden)

    Kang M

    2017-01-01

    Full Text Available Minkyung Kang,1 Hyounggeun Park,1 Joon-Ho Jun,1 Miwon Son,1 Myung Joo Kang2 1Pharmaceutical Product Research Laboratories, Dong-A ST Research Institute, Gyeonggi, 2Division of Pharmaceutical Sciences, College of Pharmacy, Dankook University, Cheonan, Chungnam, Korea Abstract: Saliva substitutes and/or lubricants are commonly employed to lessen dry mouth symptoms by stimulating and/or substituting for the secretion of saliva. In this study, a novel artificial saliva containing inorganic salts, including sodium chloride and potassium chloride, and bactericidal agents, including potassium thiocyanate and lactoperoxidase, was formulated in the form of a solution (DM-sol or gel (DM-gel. Those in vivo therapeutic efficacies were assessed in terms of saliva secretion and anti-inflammatory activity in rats and mice, respectively. Salivary secretion was promoted by mucosal application of DM-formulations in normal rats. In particular, DM-gel resulted in 2.5- and 1.9-fold greater salivary flow rates compared to normal saline and DM-sol, respectively. In an in vivo efficacy evaluation in diabetic mice with salivary hypofunction, repeated application of DM-formulations alleviated histopathological changes in the buccal mucosa in terms of atrophy and thinning of the epithelium, compared to vehicle, after 4 weeks. Moreover, the DM-sol and DM-gel were comparably effective for relieving periodontal gingivitis, reducing infiltration of inflammatory cells, and normalizing the neutrophil level in the gingival gingiva, after 4 weeks. Therefore, the novel artificial saliva is expected to facilitate salivary secretion and restore physiological conditions in the mouth of patients with salivary hypofunction. Keywords: saliva substitute, carbopol gel, hypothiocyanite–hydrogen peroxide mixture, antimicrobial activity, diabetic rats

  3. Assessment of range of uric and serum biomarkers in determination of bladder cancer severity

    Directory of Open Access Journals (Sweden)

    Popkov V.M.

    2013-12-01

    Full Text Available Purpose: to establish efficiency of a range of uric and serum biomarkers of bladder cancer for diagnostics and the prognosis of risk of development of disease recurrence. Material and methods: TPA and TPS, VEGF level research in blood serum, UBC in urine in 176 people, among which 135 patients with bladder cancer (RMP have been conducted. Group of comparison has included16 patients (patients with cystitis. The control group has been made of 25 almost healthy men. 75 patients had non-muscle invasive RMP (Ta-1N0M0. Results. It has been statistically determined that reliable growth of of TPA, TPS in blood serum and UBC in urine in patients with non-muscle invasive RMP in comparison with patients in groups of control and comparison has been established. The increase of UBC in urine of patients of this group with recurrence of tumoral growth within a year has been noted. In comparison with cytological research of urine sedimentation, molecular markers of RMP (the uric UBC and serum TPA, TPS possess diagnostic sensitivity, allow to confirm the presence of disease, to carry out diagnostics of stages of organ and extra invasion. RMP is possible to consider as an additional prognostic serum marker increase in the VEGF level in blood serum. Conclusion. Inclusion in diagnostic process in the clinical research of biomarkers showed that identification of NMIRMP increased from 18,1% in 2006 to 55,6% in 2011. The chosen volume of complex treatment allowed to reduce recurrence and lethality in the first two years from 32 to 15,5%.

  4. Spectrophotometric determination of dopamine hydrochloride in pharmaceutical, banana, urine and serum samples by potassium ferricyanide-Fe(III).

    Science.gov (United States)

    Guo, Li; Zhang, Yan; Li, Quanmin

    2009-12-01

    In the present work, we developed a simple, sensitive and inexpensive method to determine dopamine hydrochloride using potassium ferricyanide-Fe(III) by spectrophotometry. The results show that Fe(III) is deoxidized to Fe(II) by dopamine hydrochloride at pH 4.0, and then Fe(II) reacts with potassium ferricyanide to form a soluble prussian blue (KFe(III)[Fe(II)(CN)6]). The absorbance of this product was monitored over time using a spectrophotometer at an absorption maximum of 735 nm, and the amount of dopamine hydrochloride could be calculated based on the absorbance. A good linear relationship of the concentration of dopamine hydrochloride versus absorbance was observed, and a linear regression equation of A = 0.022 + 0.16921C (microg mL(-1)) was obtained. Moreover, the apparent molar absorption coefficient for the indirect determination of dopamine hydrochloride was 3.2 x 10(4) L mol(-1) cm(-1). This described method has been used to determine dopamine hydrochloride in pharmaceutical, banana, urine and serum samples with satisfactory results.

  5. Pengaruh Stimulus Pengunyahan dan Pengecapan Terhadap Kecepatan Aliran dan pH Saliva

    Directory of Open Access Journals (Sweden)

    Hj. Edeh Rolette Haroen

    2015-09-01

    Full Text Available The aim of the research were to describe how salivary flow rate and pH vary with time during use of chewing and gustatory stimulation. Fifty young adult subjects collected unstimulated saliva by spitting method, and then collected stimulated saliva by chewing paraffin wax, and a few drops of citric acid are usually placed on the subject’s tongue. The mean of saliva flow rate that unstimulated: 0.50 cc/minute; stimulated saliva by chewing paraffin wax: 1.57 cc/minute, and drops of citric acid stimulation showed that saliva flow rate: 2.98 cc/minute; and pH saliva that unstimulated 6.39; stimulated saliva by chewing paraffin wax 7.2; and stimulated saliva by citric acid: 7.55. Statistical paired t test showed that t lower than t table. The conclusion of the research showed that there were significant influences in the unstimulated salivary flow rates and pH with stimulated saliva elicited by chewing and gustatory stimulation.

  6. Determination of human albumin in serum and urine samples by constant-energy synchronous fluorescence method.

    Science.gov (United States)

    Madrakian, Tayyebeh; Bagheri, Habibollah; Afkhami, Abbas

    2015-08-01

    A sensitive spectrofluorimetric method using constant-energy synchronous fluorescence technique is proposed for the determination of human albumin without separation. In this method, no reagent was used for enhancement of the fluorescence signal of albumin in the solution. Effects of some parameters, such as energy difference between excitation and emission monochromators (ΔE), emission and excitation slit widths and scan rate of wavelength were studied and the optimum conditions were established. For this purpose factorial design and response surface method were employed for optimization of the effective parameters on the fluorescence signal. The results showed that the scan rate of the wavelength has no significant effect on the analytical signal. The calibration curve was linear in the range 0.1-220.0 µg mL(-1) of albumin with a detection limit of 7.0 × 10(-3)  µg mL(-1). The relative standard deviations (RSD) for six replicate measurements of albumin were calculated as 2.2%, 1.7% and 1.3% for 0.5, 10.0 and 100.0 µg mL(-1) albumin, respectively. Furthermore the proposed method has been employed for the determination of albumin in human serum and urine samples. Copyright © 2014 John Wiley & Sons, Ltd.

  7. Simple and suitable immunosensor for β-lactam antibiotics analysis in real matrixes: milk, serum, urine.

    Science.gov (United States)

    Merola, Giovanni; Martini, Elisabetta; Tomassetti, Mauro; Campanella, Luigi

    2015-03-15

    The anti-penicillin G was conjugated to avidin-peroxidase and biotin to obtain immunogen and competitor which were then used to develop a competitive immunosensor assay for the detection of penicillin G and other β-lactam antibiotics, with Kaff values of the order of 10(8) M(-1). The new immunosensor appears to afford a number of advantages in terms of sensitivity, possibility of "in situ" analysis, but especially of simplicity and lower costs, compared with other existing devices, or different chemical instrumental methods reported in the literature and used for the analysis of β-lactam compounds. Satisfactory results were found in the analysis of real matrixes and good recoveries were obtained by applying the standard addition method to spiked milk, urine, serum and drug samples. The new device uses an amperometric electrode for hydrogen peroxide as transducer, the BSA-penicillin G immobilized on polymeric membrane overlapping the amperometric transducer and the peroxidase enzyme as marker. It proved to be highly sensitive, inexpensive and easily reproducible; LOD was of the order of 10(-11)M. Lastly, the new immunosensor displayed low selectivity versus the entire class of β-lactam antibiotics and higher selectivity toward other classes of non-β-lactam antibiotics. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Disposable collection kit for rapid and reliable collection of saliva.

    Science.gov (United States)

    Yamaguchi, Masaki; Tezuka, Yuki; Takeda, Kazunori; Shetty, Vivek

    2015-01-01

    To describe and evaluate disposable saliva collection kit for rapid, reliable, and reproducible collection of saliva samples. The saliva collection kit comprised of a saliva absorbent swab and an extractor unit was used to retrieve whole saliva samples from 10 subjects. The accuracy and precision of the extracted volumes (3, 10, and 30 μl) were compared to similar volumes drawn from control samples obtained by passive drool. Additionally, the impact of kit collection method on subsequent immunoassay results was verified by assessing salivary cortisol levels in the samples and comparing them to controls. The recovered volumes for the whole saliva samples were 3.85 ± 0.28, 10.79 ± 0.95, and 31.18 ± 1.72 μl, respectively (CV = 8.76%) and 2.91 ± 0.19, 9.75 ± 0.43, and 29.64 ± 0.91 μl, respectively, (CV = 6.36%) for the controls. There was a close correspondence between the salivary cortisol levels from the saliva samples obtained by the collection kit and the controls (R(2)  > 0.96). The disposable saliva collection kit allows accurate and repeatable collection of fixed amounts of whole saliva and does not interfere with subsequent measurements of salivary cortisol. The simple collection process, lack of elaborate specimen recovery steps, and the short turnaround time (<3 min) should render the kit attractive to test subjects and researchers alike. © 2015 Wiley Periodicals, Inc.

  9. Fluoride in dental biofilm and saliva

    DEFF Research Database (Denmark)

    Larsen, Line Staun

    Dette ph.d.-projekt bidrager med ny viden om fordelingen af fluorid i dental biofilm og saliva. For at udforske koncentrationen af fluorid i naturlig (in vivo) biofilmvæske, biofilmsediment og i saliva, blev der udført to meget forskellige kliniske studier. Resultaterne fra tværsnitsstudiet (Studie...... I), hos en stor gruppe mennesker (n=42) der konsulterede en tandklinik for behandling, bekræfter tidligere viden, at der findes en naturlig biologisk variation i fluoridkoncentrationerne i biofilm fra forskellige intra-orale regioner samt mellem biofilmvæske, biofilmsediment og saliva...... fluoridkoncentrationer i underkæbefronten, intermediære koncentrationer i alle tre overkæberegioner og de laveste koncentrationer i underkæbemolarregionerne. Begge studier viser at biofilmsedimentet indeholder størstedelen af fluorid i biofilm. Set i et bredere perspektiv viser fundene at der er et omvendt forhold...

  10. Urine Trefoil Factors as Prognostic Biomarkers in Chronic Kidney Disease.

    Science.gov (United States)

    Yamanari, Toshio; Sugiyama, Hitoshi; Tanaka, Keiko; Morinaga, Hiroshi; Kitagawa, Masashi; Onishi, Akifumi; Ogawa-Akiyama, Ayu; Kano, Yuzuki; Mise, Koki; Ohmoto, Yasukazu; Shikata, Kenichi; Wada, Jun

    2018-01-01

    Trefoil factor family (TFF) peptides are increased in serum and urine in patients with chronic kidney disease (CKD). However, whether the levels of TFF predict the progression of CKD remains to be elucidated. We determined the TFF levels using peptide-specific ELISA in spot urine samples and performed a prospective cohort study. The association between the levels of urine TFFs and other urine biomarkers as well as the renal prognosis was analyzed in 216 CKD patients (mean age: 53.7 years, 47.7% female, 56.9% with chronic glomerulonephritis, and mean eGFR: 58.5 ml/min/1.73 m 2 ). The urine TFF1 and TFF3 levels significantly increased with the progression of CKD stages, but not the urine TFF2 levels. The TFF1 and TFF3 peptide levels predicted the progression of CKD ≥ stage 3b by ROC analysis (AUC 0.750 and 0.879, resp.); however, TFF3 alone predicted CKD progression in a multivariate logistic regression analysis (odds ratio 3.854, 95% confidence interval 1.316-11.55). The Kaplan-Meier survival curves demonstrated that patients with a higher TFF1 and TFF3 alone, or in combination with macroalbuminuria, had a significantly worse renal prognosis. The data suggested that urine TFF peptides are associated with renal progression and the outcomes in patients with CKD.

  11. Trace element measurement in Saliva by NAA and PIXE techniques

    Energy Technology Data Exchange (ETDEWEB)

    Hamidian, M.R.; Vahid Golpayegani, M.; Shojai, S. (Shahid Beheshti Medical Science Univ., Shemiran, Tehran (Iran, Islamic Republic of))

    1993-01-01

    The activity of salivary glands and the chemical and physical properties of saliva, especially in some illnesses in which the activity of salivary glands and the chemical and physical properties alter, sometimes have severe effects on sedimentation and tooth decay. Long-standing investigations have shown the relationship between salivary gland activity and saliva composition in dental carries. Many modern techniques have been employed to measure important elements in saliva. The major elements in saliva include sodium, potassium, calcium, magnesium, chlorine, phosphorus, iodine, and fluorine. It should be pointed out that the amount of minerals changes when the diet changes. The major constituent of saliva is water with a density of 1.007 g/cm[sup 3] in which 0.6% is solid, 0.3% organic material and 0.3% inorganic material. In addition to other effects, the acidity (pH) of saliva has a strong effect on tooth sedimentation. Type of work, degree of stress, and mental condition affect salivary gland activity. When the acidity of salivary fluid in the mouth and consequently over the teeth drops, sedimentation increases. In this paper, the results of trace element measurement in saliva are presented.

  12. PPARα-dependent increase of mouse urine output by gemfibrozil and fenofibrate.

    Science.gov (United States)

    Song, Danjun; Luo, Min; Dai, Manyun; Bu, Shizhong; Wang, Weihua; Zhang, Burong; Gonzalez, Frank J; Liu, Aiming

    2017-02-01

    While gemfibrozil and fenofibrate are prescribed for anti-dyslipidemia treatment, a rational basis for the use of these drugs for treatment of dyslipidemia with concurrent metabolic syndrome has not been established. In this study, wild-type and Pparα-null mice were fed gemfibrozil- or fenofibrate-containing diets for 14 days. Urine output (24 h) was monitored, and urine, serum, and liver and kidney tissues were subjected to toxicity assessment. A 2-month challenge followed by a 2-week wash-out was performed for gemfibrozil to determine urine output and the potential toxicity. A therapeutically equivalent dose of gemfibrozil was more effective than fenofibrate in increasing urine output. This regulatory effect was not observed in Pparα-null mice. In contrast, hepatomegaly induced by fenofibrate was more pronounced than that of gemfibrozil. No significant toxicity was observed in liver or kidney in the 2-month treatment with gemfibrozil. These data demonstrated PPARα mediates the increased urine output by fibrates. Considering the relative action on hepatomegaly and the regulatory effect on urine output, gemfibrozil may be the preferable drug to increase urine output. These results revealed a new pharmacodynamic effect of clinically prescribed PPARα agonists and suggested the potential value of gemfibrozil in modification of blood pressure.

  13. [The value of serum free light chain in differential diagnosis of monoclonal gammopathy of renal significance].

    Science.gov (United States)

    Li, C; Wen, Y B; Li, H; Su, W; Li, J; Cai, J F; Chen, L M; Li, X M; Li, X W

    2017-08-08

    Objective: To investigate the value of serum free light chain (FLC) in differential diagnosis of monoclonal gammopathy of renal significance (MGRS). Methods: Forty-nine hospitalized patients who underwent renal biopsy in Peking Union Medical College Hospital between January 2013 and December 2015 were included. Monoclonal gammopathy was detected by serum protein electrophoresis (SPE), serum immunofixation electrophoresis (IFE), urine IFE and serum FLC. All patients were classified as MGRS ( n =32) and monoclonal gammopathy of undetermined significance (MGUS) ( n =17). Results: Renal lesions in MGRS subgroup included light chain amyloidosis ( n =24, 75.0%), light chain deposition disease ( n =7, 21.9%), and fibrillary glomerulopathy ( n =1, 3.1%). Renal diseases in MGUS subgroup included membranous nephropathy ( n =10), focal segmental glomerulosclerosi (FSGS) ( n =3), diabetic glomerulopathy ( n =1), Henoch-Schonlein purpura nephritis ( n =1), anti-GBM disease concurrent with membranous nephropathy ( n =1) and glomerulomegaly ( n =1). Positive number of SPE, serum IFE, urine IFE and abnormal number of serum FLC ratio in MGRS subgroup were 12, 16, 23 and 30, respectively. Positive number of SPE, serum IFE, urine IFE and abnormal number of serum FLC ratio in MGUS subgroup were 11, 17, 6 and 3, respectively. MGRS and MGUS subgroups differed significantly in positive rate of serum IFE ( P value for MGRS, which was helpful for differential diagnosis of patients who had contraindication to renal biopsy.

  14. Radioimmunological method for determination of cortisol in saliva

    International Nuclear Information System (INIS)

    Maleeva, A.; Mileva, Zh.; Kekhajova, M.

    1989-01-01

    A method was developed for determination of cortisol in saliva after being previously extracted with dichlormethane. Cortisol concentration in saliva of 19 subjects was determined by this method. The saliva cortisol levels were compared with those of blood plasma. No statistically significant difference was found. The method finds acceptance primarily when frequent measurements of cortisol level are neccessary as a screening technique and when strongly abnormally high levels should be differentiated from the normal ones: in this latter case determination of plasma cortisol is mandatory. 5 tabs., 8 refs

  15. Effects of saliva collection using cotton swab on cortisol enzyme immunoassay.

    Science.gov (United States)

    Kozaki, Tomoaki; Hashiguchi, Nobuko; Kaji, Yumi; Yasukouchi, Akira; Tochihara, Yutaka

    2009-12-01

    Cotton swabs are among the most commonly used devices for collecting saliva, but various studies have reported that their use impacts the results of salivary cortisol assays. These studies, however, estimated this impact by comparing the average of the concentration and/or scatter plots. In the present study, we estimated the impact of cotton swabs on the results of salivary cortisol enzyme immunoassay (EIA) by Bland-Altman plot. Eight healthy males (aged 20-23 years) provided four saliva samples on different days to yield a total of 32 samples. Saliva samples were collected directly in plastic tubes using plastic straws and then pipetted onto cotton swabs (cotton saliva collection) and into clear sterile tubes (passive saliva collection). There was a lower correlation between cotton and passive saliva collection. Individually, four subjects showed a negative correlation between passive and cotton saliva collection. A Bland-Altman plot indicated that cotton swabs causes a proportional bias on the EIA assay result. Our findings indicate a considerable effect of using cotton swabs for saliva collection, and subject-specific variability in the impact. A Bland-Altman plot further suggests possible reasons for this effect.

  16. Clinical trial participant characteristics and saliva and DNA metrics

    Directory of Open Access Journals (Sweden)

    Richards Julie

    2009-10-01

    Full Text Available Abstract Background Clinical trial and epidemiological studies need high quality biospecimens from a representative sample of participants to investigate genetic influences on treatment response and disease. Obtaining blood biospecimens presents logistical and financial challenges. As a result, saliva biospecimen collection is becoming more frequent because of the ease of collection and lower cost. This article describes an assessment of saliva biospecimen samples collected through the mail, trial participant demographic and behavioral characteristics, and their association with saliva and DNA quantity and quality. Methods Saliva biospecimens were collected using the Oragene® DNA Self-Collection Kits from participants in a National Cancer Institute funded smoking cessation trial. Saliva biospecimens from 565 individuals were visually inspected for clarity prior to and after DNA extraction. DNA samples were then quantified by UV absorbance, PicoGreen®, and qPCR. Genotyping was performed on 11 SNPs using TaqMan® SNP assays and two VNTR assays. Univariate, correlation, and analysis of variance analyses were conducted to observe the relationship between saliva sample and participant characteristics. Results The biospecimen kit return rate was 58.5% among those invited to participate (n = 967 and 47.1% among all possible COMPASS participants (n = 1202. Significant gender differences were observed with males providing larger saliva volume (4.7 vs. 4.5 ml, p = 0.019, samples that were more likely to be judged as cloudy (39.5% vs. 24.9%, p 0.21, P Conclusion Findings from this study show that demographic and behavioral characteristics of smoking cessation trial participants have significant associations with saliva and DNA metrics, but not with the performance of TaqMan® SNP or VNTR genotyping assays. Trial registration COMPASS; registered as NCT00301145 at clinicaltrials.gov.

  17. Effect of urine pH changed by dietary intervention on uric acid clearance mechanism of pH-dependent excretion of urinary uric acid

    Directory of Open Access Journals (Sweden)

    Kanbara Aya

    2012-06-01

    Full Text Available Abstract Background The finding reported in a previous paper - alkalization of urine facilitates uric acid excretion - is contradictory to what one might expect to occur: because food materials for the alkalization of urine contain fewer purine bodies than those for acidification, less uric acid in alkaline urine should have been excreted than in acid urine. To make clear what component of uric acid excretion mechanisms is responsible for this unexpected finding, we simultaneously collected data for the concentration of both creatinine and uric acid in serum as well as in urine, in order to calculate both uric acid and creatinine clearances. Methods Within the framework of the Japanese government’s health promotion program, we made recipes which consisted of protein-rich and less vegetable-fruit food materials for H + -load (acidic diet and others composed of less protein and more vegetable-fruit rich food materials (alkaline diet. This is a crossover study within some limitations. Healthy female students, who had no medical problems at the regular physical examination provided by the university, were enrolled in this consecutive 5-day study for each test. From whole-day collected urine, total volume, pH, organic acid, creatinine, uric acid, titratable acid and all cations (Na+,K+,Ca2+,Mg2+,NH4+ and anions (Cl−,SO42−,PO4− necessary for the estimation of acid–base balance were measured. In the early morning before breakfast of the 1st, 3rd and 5th experimental day, we sampled 5 mL of blood to estimate the creatinine and uric acid concentration in serum. Results and discussion Urine pH reached a steady state 3 days after switching from ordinary daily diets to specified regimens. The amount of acid generated ([SO42−] + organic acid − gut alkaliwas linearly related with the excretion of acid (titratable acid + [NH4+] − [HCO3−], indicating that H + in urine is generated by the metabolic degradation of

  18. Hypoglycin A Content in Blood and Urine Discriminates Horses with Atypical Myopathy from Clinically Normal Horses Grazing on the Same Pasture.

    Directory of Open Access Journals (Sweden)

    M Bochnia

    Full Text Available Hypoglycin A (HGA in seeds of Acer spp. is suspected to cause seasonal pasture myopathy in North America and equine atypical myopathy (AM in Europe, fatal diseases in horses on pasture. In previous studies, this suspicion was substantiated by the correlation of seed HGA content with the concentrations of toxic metabolites in urine and serum (MCPA-conjugates of affected horses. However, seed sampling was conducted after rather than during an outbreak of the disease. The aim of this study was to further confirm the causality between HGA occurrence and disease outbreak by seed sampling during an outbreak and the determination of i HGA in seeds and of ii HGA and MCPA-conjugates in urine and serum of diseased horses. Furthermore, cograzing healthy horses, which were present on AM affected pastures, were also investigated. AM-pastures in Germany were visited to identify seeds of Acer pseudoplatanus and serum (n = 8 as well as urine (n = 6 from a total of 16 diseased horses were analyzed for amino acid composition by LC-ESI-MS/MS, with a special focus on the content of HGA. Additionally, the content of its toxic metabolite was measured in its conjugated form in body fluids (UPLC-MS/MS. The seeds contained 1.7-319.8 μg HGA/g seed. The content of HGA in serum of affected horses ranged from 387.8-8493.8 μg/L (controls < 10 μg/L, and in urine from 143.8-926.4 μg/L (controls < 10 μg/L, respectively. Healthy cograzing horses on AM-pastures showed higher serum (108.8 ± 83.76 μg/L and urine concentrations (26.9 ± 7.39 μg/L compared to control horses, but lower concentrations compared to diseased horses. The range of MCPA-carnitine and creatinine concentrations found in diseased horses in serum and urine were 0.17-0.65 mmol/L (controls < 0.01, and 0.34-2.05 μmol/mmoL (controls < 0.001, respectively. MCPA-glycine levels in urine of cograzing horses were higher compared to controls. Thus, the causal link between HGA intoxication and disease outbreak

  19. Noninvasive glucose monitoring using saliva nano-biosensor

    Directory of Open Access Journals (Sweden)

    Wenjun Zhang

    2015-06-01

    Full Text Available Millions of people worldwide live with diabetes and several millions die from it each year. A noninvasive, painless method of glucose testing would highly improve compliance and glucose control while reducing complications and overall disease management costs. To provide accurate, low cost, and continuous glucose monitoring, we have developed a unique, disposable saliva nano-biosensor. More than eight clinical trials on real-time noninvasive salivary glucose monitoring were carried out on two healthy individuals (a 2–3 h-period for each trial, including both regular food and standard glucose beverage intake with more than 35 saliva samples obtained. Excellent clinical accuracy was revealed as compared to the UV Spectrophotometer. By measuring subjects’ salivary glucose and blood glucose in parallel, we found the two generated profiles share the same fluctuation trend but the correlation between them is individual dependent. There is a time lag between the peak glucose values from blood and from saliva. However, the correlation between the two glucose values at fasting is constant for each person enabling noninvasive diagnosis of diabetes through saliva instead of blood. Furthermore, a good correlation of glucose levels in saliva and in blood before and 2 h after glucose intake was observed. Glucose monitoring before and 2 h after meals is usually prescribed by doctors for diabetic patients. Thus, this disposable biosensor will be an alternative for real-time salivary glucose tracking at any time.

  20. Saliva as a future potential predictor for various periodontal diseases

    Directory of Open Access Journals (Sweden)

    Zahreni Hamzah

    2011-06-01

    Full Text Available Background: There are many diagnostic biomarkers have been found in saliva. Saliva contains a wide variety of proteins, including bacteria and products, enzymes, inflammatory mediators and host response modifiers, products of tissue breakdown. Purpose: The purpose of the study was studied current development of diagnostic biomarkers in saliva that will lead to the development of simple and accurate diagnostic tools for periodental disease. Reviews: Specifically, the salivary biomarkers divided for three aspects of periodontitis i.e. inflammation, collagen degradation and bone turnover, correlated with clinical features of periodontal disease. The diagnostic biomarkers is in saliva, such as enzyme, immunoglobulin, cytokines, bacteria and bacterial products, hormones. For the past two decades, oral health researchers have been developing salivary diagnostic tools to monitor oral diseases. Conclusion: The indicators of acute periodontitis can detect with ß-glucuronidase and AST, IL-1β, and MMP-8, whereas indicators for chronic periodontitis can detect with ALP. The indicators for collagen degradation and bone turnover suggest ICTP, fibronectin fragments, and osteonectin. The indicators of severity of periodontitis especially can be predict by B. forsythus.Latar belakang: Banyak biomarker telah ditemukan dalam saliva. Saliva terdiri dari berbagai protein unik meliputi bakteri dan produk bakteri, enzim, mediator inflamasi dan modifikasi respon host (immunoglobulin, sitokin, produk kerusakan jaringan (telopeptida kolagen, osteokalsin, proteoglikan, fragmen fibronectin. Tujuan: Mengkaji biomarker dalam saliva untuk pengembangan metode diagnostik sederhana dan akurat untuk penyakit periodontal. Tinjauan Pustaka: Secara khusus, biomarker saliva pada periodontitis dibagi dalam tiga aspek yaitu inflamasi, dan degradasi kolagen serta pergantian tulang. Biomarker diagnostik dalam saliva, meliputi enzim, imunoglobulin, sitokin, bakteri dan produk

  1. Saliva-catalyzed hydrolysis of a ketobemidone ester prodrug

    DEFF Research Database (Denmark)

    Hansen, L.B.; Christrup, Lona Louring; Bundgaard, H.

    1992-01-01

    Saliva enzyme-catalysed hydrolysis of ester prodrugs or drugs containing sensitive ester groups may be a limiting factor for the buccal absorption of such compounds. Using the isopropyl carbonate ester of ketobemidone as a model substance of a hydrolysis-sensitive prodrug the esterase activity...... of human saliva has been characterized as a function of various factors. The esterase activity was found to decrease rapidly upon storage of the saliva at 37°C. The activity increased with increasing pH in the range 4.5-7.4 and with increasing salivation flow rate up to a rate of 0.9 ml min. Under resting...... conditions, the flow rate was about 0.2 ml min which implied a greatly decreased esterase activity. The activity was highest after fasting and decreased after intake of a meal. The intraindividual variation in the saliva esterase activity was small whereas a larger interindividual variation was found....

  2. Detection of prostate specific antigen (PSA) in human saliva using an ultra-sensitive nanocomposite of graphene nanoplatelets with diblock-co-polymers and Au electrodes.

    Science.gov (United States)

    Khan, M S; Dighe, K; Wang, Z; Srivastava, I; Daza, E; Schwartz-Dual, A S; Ghannam, J; Misra, S K; Pan, D

    2018-02-26

    Prostate-specific antigen (PSA) is a commonly used biomarker for the detection of prostate cancer (PCa) and there are numerous data available for its invasive detection in the serum and whole blood. In this work, an electrochemical sensing method was devised to detect traces of PSA in human saliva using a hybrid nanocomposite of graphene nanoplatelets with diblock co-polymers and Au electrodes (GRP-PS 67 -b-PAA 27 -Au). The pure graphitic composition on filter paper provides significantly high electrical and thermal conductivity while PS 67 -b-PAA 27 makes an amphiphilic bridge between GRP units. The sensor utilizes the binding of an anti-PSA antibody with an antigen-PSA to act as a resistor in a circuit providing an impedance change that in turn allows for the detection and quantification of PSA in saliva samples. A miniaturized electrical impedance analyzer was interfaced with a sensor chip and the data were recorded in real-time using a Bluetooth-enabled module. This fully integrated and optimized sensing device exhibited a wide PSA range of detection from 0.1 pg mL -1 to 100 ng mL -1 (R 2 = 0.963) with a lower limit of detection of 40 fg mL -1 . The performance of the biosensor chip was validated with an enzyme-linked immunosorbent assay technique with a regression coefficient as high as 0.940. The advantages of the newly developed saliva-PSA electrical biosensor over previously reported serum-PSA electrochemical biosensors include a faster response time (3-5 min) to achieve a stable electrical signal for PSA detection, high selectivity, improved sensitivity, no additional requirement of a redox electrolyte for electron exchange and excellent shelf life. The presented sensor is aimed for clinical commercialization to detect PSA in human saliva.

  3. Urine Cytology

    Science.gov (United States)

    Urine cytology Overview Urine cytology is a test to look for abnormal cells in your urine. It's used with other tests and procedures to diagnose ... bladder cancer. Your doctor might recommend a urine cytology test if you have blood in your urine ( ...

  4. Understanding of xerostomia and strategies for the development of artificial saliva.

    Science.gov (United States)

    Kho, Hong-Seop

    2014-01-01

    Xerostomia is becoming a major issue in dental and medical clinics with an increase of aged population. Medication is the most common etiology of xerostomia, while the most severe xerostomia generally occurs in patients with a history of head and neck radiotherapy. Xerostomic patients usually suffer from diminished quality of life due to various symptoms and complications. Decreased salivary output is a definite objective sign, but oral mucosal wetness is a more reliable factor for the evaluation of xerostomia. At present there are no effective therapeutic methods for the treatment of xerostomia. Sialogogues may have problematic side effects and their therapeutic effects last only brief duration. Artificial saliva typically does not produce satisfactory results in therapeutic efficacy. Therefore, further research and development of better therapeutic modalities are necessary. The basic concept for the development of ideal and functional artificial saliva is the mimicry of natural human saliva. We need proper candidate molecules and antimicrobial supplements to simulate the rheological and biological properties of human saliva. We also need better understanding of the interactions between the ingredients of artificial saliva themselves and between the ingredients and components of human saliva both in solution and on surface phases. In addition, we need accepted measures to evaluate the efficacy of artificial saliva. In conclusion, for the development of ideal artificial saliva, research based on the understanding of pathophysiology of xerostomia and knowledge about rheological and biological functions of human saliva are necessary.

  5. Periodontitis diagnostics using resonance Raman spectroscopy on saliva

    Science.gov (United States)

    Gonchukov, S.; Sukhinina, A.; Bakhmutov, D.; Biryukova, T.; Tsvetkov, M.; Bagratashvily, V.

    2013-07-01

    In view of its wealth of molecular information, Raman spectroscopy has been the subject of active biomedical research. The aim of this work is Raman spectroscopy (RS) application for the determination of molecular biomarkers in saliva with the objective of early periodontitis detection. As was shown in our previous study, carotenoids contained in saliva can be molecular fingerprint information for the periodontitis level. It is shown here that the carotenoid RS lines at wavenumbers of 1156 and 1524 cm-1 can be easily detected and serve as reliable biomarkers of periodontitis using resonance Raman spectroscopy of dry saliva.

  6. Periodontitis diagnostics using resonance Raman spectroscopy on saliva

    International Nuclear Information System (INIS)

    Gonchukov, S; Sukhinina, A; Bakhmutov, D; Biryukova, T; Tsvetkov, M; Bagratashvily, V

    2013-01-01

    In view of its wealth of molecular information, Raman spectroscopy has been the subject of active biomedical research. The aim of this work is Raman spectroscopy (RS) application for the determination of molecular biomarkers in saliva with the objective of early periodontitis detection. As was shown in our previous study, carotenoids contained in saliva can be molecular fingerprint information for the periodontitis level. It is shown here that the carotenoid RS lines at wavenumbers of 1156 and 1524 cm −1 can be easily detected and serve as reliable biomarkers of periodontitis using resonance Raman spectroscopy of dry saliva. (letter)

  7. UPLC-Q-TOF/MS based metabolomic profiling of serum and urine of hyperlipidemic rats induced by high fat diet

    Directory of Open Access Journals (Sweden)

    Qiong Wu

    2014-12-01

    Full Text Available Hyperlipidemia is considered to be a high lipid level in blood, can induce metabolic disorders and dysfunctions of the body, and results in some severe complications. Therefore, hunting for some metabolite markers and clarifying the metabolic pathways in vivo will be an important strategy in the treatment and prevention of hyperlipidemia. In this study, a rat model of hyperlipidemia was constructed according to histopathological data and biochemical parameters, and the metabolites of serum and urine were analyzed by UPLC-Q-TOF/MS. Combining pattern recognition and statistical analysis, 19 candidate biomarkers were screened and identified. These changed metabolites indicated that during the development and progression of hyperlipidemia, energy metabolism, lipid metabolism, amino acid metabolism and nucleotide metabolism were mainly disturbed, which are reported to be closely related to diabetes, cardiovascular diseases, etc. This study demonstrated that a UPLC-Q-TOF/MS based metabolomic approach is useful to profile the alternation of endogenous metabolites of hyperlipidemia. Keywords: UPLC-Q-TOF/MS, Hyperlipidemia, Metabolomic, Pattern recognition

  8. Inorganic component of saliva during fasting and after fast break

    OpenAIRE

    Samad, Rasmidar

    2016-01-01

    Oral health is closely related to salivary components. Saliva consists of water, inorganic and organic materials. Fasting changes one???s meal and drinking time that in turn can affect the environment in oral cavity, including inorganic componenet of saliva. The purpose of this study is to determine the inorganic component of saliva during fasting and after fast break.

  9. Hypoglycin A Content in Blood and Urine Discriminates Horses with Atypical Myopathy from Clinically Normal Horses Grazing on the Same Pasture

    Science.gov (United States)

    Bochnia, M.; Ziegler, J.; Sander, J.; Uhlig, A.; Schaefer, S.; Vollstedt, S.; Glatter, M.; Abel, S.; Recknagel, S.; Schusser, G. F.; Wensch-Dorendorf, M.; Zeyner, A.

    2015-01-01

    Hypoglycin A (HGA) in seeds of Acer spp. is suspected to cause seasonal pasture myopathy in North America and equine atypical myopathy (AM) in Europe, fatal diseases in horses on pasture. In previous studies, this suspicion was substantiated by the correlation of seed HGA content with the concentrations of toxic metabolites in urine and serum (MCPA-conjugates) of affected horses. However, seed sampling was conducted after rather than during an outbreak of the disease. The aim of this study was to further confirm the causality between HGA occurrence and disease outbreak by seed sampling during an outbreak and the determination of i) HGA in seeds and of ii) HGA and MCPA-conjugates in urine and serum of diseased horses. Furthermore, cograzing healthy horses, which were present on AM affected pastures, were also investigated. AM-pastures in Germany were visited to identify seeds of Acer pseudoplatanus and serum (n = 8) as well as urine (n = 6) from a total of 16 diseased horses were analyzed for amino acid composition by LC-ESI-MS/MS, with a special focus on the content of HGA. Additionally, the content of its toxic metabolite was measured in its conjugated form in body fluids (UPLC-MS/MS). The seeds contained 1.7–319.8 μg HGA/g seed. The content of HGA in serum of affected horses ranged from 387.8–8493.8 μg/L (controls horses on AM-pastures showed higher serum (108.8 ± 83.76 μg/L) and urine concentrations (26.9 ± 7.39 μg/L) compared to control horses, but lower concentrations compared to diseased horses. The range of MCPA-carnitine and creatinine concentrations found in diseased horses in serum and urine were 0.17–0.65 mmol/L (controls horses were higher compared to controls. Thus, the causal link between HGA intoxication and disease outbreak could be further substantiated, and the early detection of HGA in cograzing horses, which are clinically normal, might be a promising step in prophylaxis. PMID:26378918

  10. Microbial community profiling of human saliva using shotgun metagenomic sequencing.

    Directory of Open Access Journals (Sweden)

    Nur A Hasan

    Full Text Available Human saliva is clinically informative of both oral and general health. Since next generation shotgun sequencing (NGS is now widely used to identify and quantify bacteria, we investigated the bacterial flora of saliva microbiomes of two healthy volunteers and five datasets from the Human Microbiome Project, along with a control dataset containing short NGS reads from bacterial species representative of the bacterial flora of human saliva. GENIUS, a system designed to identify and quantify bacterial species using unassembled short NGS reads was used to identify the bacterial species comprising the microbiomes of the saliva samples and datasets. Results, achieved within minutes and at greater than 90% accuracy, showed more than 175 bacterial species comprised the bacterial flora of human saliva, including bacteria known to be commensal human flora but also Haemophilus influenzae, Neisseria meningitidis, Streptococcus pneumoniae, and Gamma proteobacteria. Basic Local Alignment Search Tool (BLASTn analysis in parallel, reported ca. five times more species than those actually comprising the in silico sample. Both GENIUS and BLAST analyses of saliva samples identified major genera comprising the bacterial flora of saliva, but GENIUS provided a more precise description of species composition, identifying to strain in most cases and delivered results at least 10,000 times faster. Therefore, GENIUS offers a facile and accurate system for identification and quantification of bacterial species and/or strains in metagenomic samples.

  11. Urine neutrophil gelatinase-associated lipocalin (NGAL as a biomarker for acute canine kidney injury

    Directory of Open Access Journals (Sweden)

    Lee Ya-Jane

    2012-12-01

    Full Text Available Abstract Background Biomarkers for the early prediction of canine acute kidney injury (AKI are clinically important. Recently, neutrophil gelatinase-associated lipocalin (NGAL was found to be a sensitive biomarker for the prediction of human AKI at a very early stage and the development of AKI after surgery. However, NGAL has not yet been studied with respect to dog kidney diseases. The application of NGAL canine AKI was investigated in this study. Results The canine NGAL gene was successfully cloned and expressed. Polyclonal antibodies against canine NGAL were generated and used to develop an ELISA for measuring NGAL protein in serum and urine samples that were collected from 39 dogs at different time points after surgery. AKI was defined by the standard method, namely a serum creatinine increase of greater than or equal to 26.5 μmol/L from baseline within 48 h. At 12 h after surgery, compared to the group without AKI (12 dogs, the NGAL level in the urine of seven dogs with AKI was significantly increased (median 178.4 pg/mL vs. 88.0 pg/mL, and this difference was sustained to 72 h. Conclusion As the increase in NGAL occurred much earlier than the increase in serum creatinine, urine NGAL seems to be able to serve as a sensitive and specific biomarker for the prediction of AKI in dogs.

  12. Saliva Polymerase-Chain-Reaction Assay for Cytomegalovirus Screening in Newborns

    Science.gov (United States)

    Boppana, Suresh B.; Ross, Shannon A.; Shimamura, Masako; Palmer, April L.; Ahmed, Amina; Michaels, Marian G.; Sánchez, Pablo J.; Bernstein, David I.; Tolan, Robert W.; Novak, Zdenek; Chowdhury, Nazma; Britt, William J.; Fowler, Karen B.

    2011-01-01

    BACKGROUND Congenital cytomegalovirus (CMV) infection is an important cause of hearing loss, and most infants at risk for CMV-associated hearing loss are not identified early in life because of failure to test for the infection. The standard assay for newborn CMV screening is rapid culture performed on saliva specimens obtained at birth, but this assay cannot be automated. Two alternatives — real-time polymerase-chain-reaction (PCR)–based testing of a liquid-saliva or dried-saliva specimen obtained at birth — have been developed. METHODS In our prospective, multicenter screening study of newborns, we compared real-time PCR assays of liquid-saliva and dried-saliva specimens with rapid culture of saliva specimens obtained at birth. RESULTS A total of 177 of 34,989 infants (0.5%; 95% confidence interval [CI], 0.4 to 0.6) were positive for CMV, according to at least one of the three methods. Of 17,662 newborns screened with the use of the liquid-saliva PCR assay, 17,569 were negative for CMV, and the remaining 85 infants (0.5%; 95% CI, 0.4 to 0.6) had positive results on both culture and PCR assay. The sensitivity and specificity of the liquid-saliva PCR assay were 100% (95% CI, 95.8 to 100) and 99.9% (95% CI, 99.9 to 100), respectively, and the positive and negative predictive values were 91.4% (95% CI, 83.8 to 96.2) and 100% (95% CI, 99.9 to 100), respectively. Of 17,327 newborns screened by means of the dried-saliva PCR assay, 74 were positive for CMV, whereas 76 (0.4%; 95% CI, 0.3 to 0.5) were found to be CMV-positive on rapid culture. Sensitivity and specificity of the dried-saliva PCR assay were 97.4% (95% CI, 90.8 to 99.7) and 99.9% (95% CI, 99.9 to 100), respectively. The positive and negative predictive values were 90.2% (95% CI, 81.7 to 95.7) and 99.9% (95% CI, 99.9 to 100), respectively. CONCLUSIONS Real-time PCR assays of both liquid- and dried-saliva specimens showed high sensitivity and specificity for detecting CMV infection and should be

  13. Effects of saliva collection using cotton swabs on melatonin enzyme immunoassay.

    Science.gov (United States)

    Kozaki, Tomoaki; Lee, Soomin; Nishimura, Takayuki; Katsuura, Tetsuo; Yasukouchi, Akira

    2011-01-10

    Although various acceptable and easy-to-use devices have been used for saliva collection, cotton swabs are among the most common ones. Previous studies reported that cotton swabs yield a lower level of melatonin detection. However, this statistical method is not adequate for detecting an agreement between cotton saliva collection and passive saliva collection, and a test for bias is needed. Furthermore, the effects of cotton swabs have not been examined at lower melatonin level, a level at which melatonin is used for assessment of circadian rhythms, namely dim light melatonin onset (DLMO). In the present study, we estimated the effect of cotton swabs on the results of salivary melatonin assay using the Bland-Altman plot at lower level. Nine healthy males were recruited and each provided four saliva samples on a single day to yield a total of 36 samples. Saliva samples were directly collected in plastic tubes using plastic straws, and subsequently pipetted onto cotton swabs (cotton saliva collection) and into clear sterile tubes (passive saliva collection). The melatonin levels were analyzed in duplicate using commercially available ELISA kits. The mean melatonin concentration in cotton saliva collection samples was significantly lower than that in passive saliva collection samples at higher melatonin level (>6 pg/mL). The Bland-Altman plot indicated that cotton swabs causes relative and proportional biases in the assay results. For lower melatonin level (<6 pg/mL), although the BA plots didn't show proportional and relative biases, there was no significant correlation between passive and cotton saliva collection samples. Our findings indicate an interference effect of cotton swabs on the assay result of salivary melatonin at lower melatonin level. Cotton-based collection devices might, thus, not be suitable for assessment of DLMO.

  14. INFRARED STUDIES OF HUMAN SALIVA. IDENTIFICATION OF A FACTOR IN HUMAN SALIVA PRODUCING AN INFRARED ABSORBANCE MAXIMUM AT 4.9 MICRONS

    Science.gov (United States)

    An absorption maximum was observed at 4.9 microns in infrared spectra of human parotid saliva. The factor causing this absorbance was found to be a...nitrate, and heat stability. Thiocyanate was then determined in 16 parotid saliva samples by a spectrophotometric method, which involved formation of

  15. Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks

    Energy Technology Data Exchange (ETDEWEB)

    Bernini, Patrizia; Bertini, Ivano, E-mail: bertini@cerm.unifi.it; Luchinat, Claudio [University of Florence, Magnetic Resonance Center (CERM) (Italy); Nincheri, Paola; Staderini, Samuele [FiorGen Foundation (Italy); Turano, Paola [University of Florence, Magnetic Resonance Center (CERM) (Italy)

    2011-04-15

    {sup 1}H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0-4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.

  16. Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks.

    Science.gov (United States)

    Bernini, Patrizia; Bertini, Ivano; Luchinat, Claudio; Nincheri, Paola; Staderini, Samuele; Turano, Paola

    2011-04-01

    (1)H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0-4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.

  17. Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks

    International Nuclear Information System (INIS)

    Bernini, Patrizia; Bertini, Ivano; Luchinat, Claudio; Nincheri, Paola; Staderini, Samuele; Turano, Paola

    2011-01-01

    1 H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0−4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.

  18. ELISA for the core protein of the cartilage large aggregating proteoglycan, aggrecan: comparison with the concentrations of immunogenic keratan sulphate in synovial fluid, serum and urine

    DEFF Research Database (Denmark)

    Møller, H J; Larsen, F S; Ingemann-Hansen, T

    1994-01-01

    ELISA. The within-assay and between-assay coefficients of variation were 4.9-8.9% and 11.1-13.0%, respectively. The mean concentrations of core protein in synovial fluid, serum and urine were 76.4 micrograms/ml, 104.0 ng/ml and 81.0 ng/ml, respectively. In synovial fluids the concentrations were closely......Immunological assays for fragments of the cartilage large aggregating proteoglycan, aggrecan, have been widely used to monitor cartilage turnover. These assays have commonly employed the monoclonal keratan sulphate antibody, 5D4. Keratan sulphate, however, is present in many tissues and 5D4...

  19. Comparison of methods, storage conditions, and time to analysis of serum and urine creatinine measured from microsamples by liquid chromatography mass spectrometery (LC/MS) vs. Jaffe.

    Science.gov (United States)

    Askenazi, David J; Moore, John F; Fineberg, Naomi; Koralkar, Rajesh; Clevenger, Stephanie; Sharer, Jon Daniel

    2014-09-01

    Measurement of serum creatinine (SCr) and urine creatinine (UCr) is regularly used in clinical and research settings. For small animal experiments and for studies in which sample collection is spare (i.e. neonatal cohorts), measuring SCr and UCr using tiny amounts of sample (as low as 10 mcl) would maximize exploration and minimize iatrogenic blood loss. We performed an evaluation in six healthy adults to determine differences between SCr and UCr values in different methodologies and storage environments and time. Study was conducted using 20 mcl of sample. Analyses were done using two-way repeated measures of ANOVA. Scr values showed no significant differences between LC/MS vs. Jaffe. However, the SCr using LC/MS method was lowest when measured immediately compared to other time points (F = 7.2; Psamples measured by LC/MS. UCr measurements by LC/MS vary more over time, mostly due to the sample measured after 1 year; therefore, storage of urine for more than 90 days measured by LC/MS may provide altered results. © 2014 Wiley Periodicals, Inc.

  20. The association between saliva control, silent saliva penetration, aspiration, and videofluoroscopic findings in Parkinson's disease patients

    Science.gov (United States)

    Rajaei, Ali; Ashtari, Fereshteh; Azargoon, Seyed Abolfazl; Chitsaz, Ahmad; Nilforoush, Mohammad Hussein; Taheri, Masoud; Sadeghi, Saba

    2015-01-01

    Background: Dysphagia is a common disorder among patients with Parkinson's disease (PD). It occurs in up to 80% of all (PD) patients during the early stages of the disease and up to 95% in the advanced stages; but professionals may not hear from the patients about dysphagia symptoms until these symptoms reach an advanced stage and lead to medical complications. Materials and Methods: Thirty-three PD patients (mean age 66.09 ± 9.4 years; 24 men, nine women) participated in this study at our Neurology Institute, between April 20, 2013, and October 26, 2013. They were asked two questions; one about saliva control and the other about silent saliva penetration and aspiration. Next, they underwent the videofluoroscopic swallowing study (VFSS). Results: The Pearson Correlation coefficient between the Penetration–Aspiration Scale (PAS) scores and question 1 scores was 0.48 (P < 0.05, =0.25), and there was a significant correlation between the PAS scores and question 2 scores, and also question 1 scores + question 2 scores (r = 0.589, P < 0.05, =0 and r = 0589, P < 0.05, =0). Conclusions: This study showed a significant correlation between the questions about saliva control, silent saliva penetration, and aspiration, and laryngeal penetration and aspiration during VFSS. Therefore, by using these two questions, the potential silent laryngeal penetration and aspiration during meals could be detected before it led to aspiration pneumonia. Taking the benefit of these questions, as a part of the swallowing assessment of PD patients, is recommended. PMID:26261810

  1. Joint detection and clinical analyse of urine β2-microglobulin, albumin and immunoglobulin G in patients with hyperthyroidism

    International Nuclear Information System (INIS)

    Cui Liqun; Yang Baojun

    2009-01-01

    Objective: To evaluate the clinical significance of joint detection of urine β 2 -microglobulin (β 2 MG), albumin (Alb) and immunoglobulin G (IgG) in patients with hyperthyroidism Methods: Urine β 2 -MG, Alb, IgG and serum thyroid hormone free trilute (FT 3 ), free thyroxin (FT 4 ) of 45 healthy volunteers (as control group) and 120 patients with hyperthyroidism were measured by radioimmunoassay (RIA). Results: The urine β 2 -MG, Alb and IgG in the hyperthyroidism group (including the primary group (group A) and uncured group (group B)) were distinctly higher than those in control group and hyperthyroidism cured group (group C) (t=6.682, P 2 -MG, Alb and IgG with serum FT 3 and FT 4 (the related coefficients were 0.98, 0.88, 0.93, 0.87, 0.94, and 0.85 respectively). Conclusion: It is important to measure urine β 2 -MG together with Alb and IgG in early judgment of the location and degree of kidney injury, as well as the severity of disease in patients with hyperthyroidism. (authors)

  2. Bilirubin - urine

    Science.gov (United States)

    Conjugated bilirubin - urine; Direct bilirubin - urine ... Bilirubin is not normally found in the urine. ... Increased levels of bilirubin in the urine may be due to: Biliary tract disease Cirrhosis Gallstones in the biliary tract Hepatitis Liver disease ...

  3. Effects of saliva collection using cotton swabs on melatonin enzyme immunoassay

    Directory of Open Access Journals (Sweden)

    Katsuura Tetsuo

    2011-01-01

    Full Text Available Abstract Background Although various acceptable and easy-to-use devices have been used for saliva collection, cotton swabs are among the most common ones. Previous studies reported that cotton swabs yield a lower level of melatonin detection. However, this statistical method is not adequate for detecting an agreement between cotton saliva collection and passive saliva collection, and a test for bias is needed. Furthermore, the effects of cotton swabs have not been examined at lower melatonin level, a level at which melatonin is used for assessment of circadian rhythms, namely dim light melatonin onset (DLMO. In the present study, we estimated the effect of cotton swabs on the results of salivary melatonin assay using the Bland-Altman plot at lower level. Methods Nine healthy males were recruited and each provided four saliva samples on a single day to yield a total of 36 samples. Saliva samples were directly collected in plastic tubes using plastic straws, and subsequently pipetted onto cotton swabs (cotton saliva collection and into clear sterile tubes (passive saliva collection. The melatonin levels were analyzed in duplicate using commercially available ELISA kits. Results The mean melatonin concentration in cotton saliva collection samples was significantly lower than that in passive saliva collection samples at higher melatonin level (>6 pg/mL. The Bland-Altman plot indicated that cotton swabs causes relative and proportional biases in the assay results. For lower melatonin level ( Conclusion Our findings indicate an interference effect of cotton swabs on the assay result of salivary melatonin at lower melatonin level. Cotton-based collection devices might, thus, not be suitable for assessment of DLMO.

  4. The Analysis of Cyanide and Its Breakdown Products in Biological Samples

    Science.gov (United States)

    2010-01-01

    Biological sampleb Speciesc CN Minutes-hours Some in a few species Low Blood, urine, saliva, tissue, expired air, rumen Human, fish, cow, mouse, rat...higher content in the left ventricle of fire victims. Journal of Chromatography 490 (1989):319–327. 96. R. H. Cardozo and I. S. Edelman, The volume of...Hagedorn, and R. Schulz, Development of a method for determination of cyanide concentrations in serum and rumen fluid of cattle. American Journal of

  5. Protein components in saliva and plaque fluid from irradiated primates

    Energy Technology Data Exchange (ETDEWEB)

    Edgar, W.M.; Bowen, W.H.; Cole, M.F. (Caries Prevention and Research Branch, National Caries Program, NIDR, Bethesda, Maryland, USA)

    1982-01-01

    Irradiation of the major salivary glands of monkeys (Macaca mulatta) fed cariogenic diets leads to caries clinically indistinguishable from radiation caries in man. This study compares the organic compostion of individual samples of plaque fluid and saliva from irradiated and control monkeys receiving the same cariogenic diet. Plaque and saliva were collected from fasting, tranquillised animals. Four irradiated animals were sampled repeatedly as were non-irradiated controls. Total protein, albumin, immunoglobulins A, G, and M, and the third component of complement (C'3) were quantitated in plaque fluid and whole saliva. Salivary amylase and peroxidase activities were also determined. Plaque fluid and saliva samples were also subjected to polyacrylamide gel electrophoresis. The total viable anaerobic count and numbers of Streptococcus mutans were determined in samples of plaque. The results suggest that the major effect of irradiation leading to increased numbers of S. mutans and caries susceptibility is in the amount, and not the composition, of the saliva produced by the residual gland tissue. The scanty flow of saliva may reduce the effectiveness of cleansing, buffering and lubrication mechanisms as well as resulting in a marked reduction in the total amount of specific and non-specific immune factors entering the mouth.

  6. Protein components in saliva and plaque fluid from irradiated primates

    International Nuclear Information System (INIS)

    Edgar, W.M.; Bowen, W.H.; Cole, M.F.

    1982-01-01

    Irradiation of the major salivary glands of monkeys (Macaca mulatta) fed cariogenic diets leads to caries clinically indistinguishable from radiation caries in man. This study compares the organic compostion of individual samples of plaque fluid and saliva from irradiated and control monkeys receiving the same cariogenic diet. Plaque and saliva were collected from fasting, tranquillised animals. Four irradiated animals were sampled repeatedly as were non-irradiated controls. Total protein, albumin, immunoglobulins A, G, and M, and the third component of complement (C'3) were quantitated in plaque fluid and whole saliva. Salivary amylase and peroxidase activities were also determined. Plaque fluid and saliva samples were also subjected to polyacrylamide gel electrophoresis. The total viable anaerobic count and numbers of Streptococcus mutans were determined in samples of plaque. The results suggest that the major effect of irradiation leading to increased numbers of S. mutans and caries susceptibility is in the amount, and not the composition, of the saliva produced by the residual gland tissue. The scanty flow of saliva may reduce the effectiveness of cleansing, buffering and lubrication mechanisms as well as resulting in a marked reduction in the total amount of specific and non-specific immune factors entering the mouth. (author)

  7. Protein components in saliva and plaque fluid from irradiated primates

    Energy Technology Data Exchange (ETDEWEB)

    Edgar, W M; Bowen, W H; Cole, M F [Caries Prevention and Research Branch, National Caries Program, NIDR, Bethesda, Maryland, USA

    1982-01-01

    Irradiation of the major salivary glands of monkeys (Macaca mulatta) fed cariogenic diets leads to caries clinically indistinguishable from radiation caries in man. This study compares the organic compostion of individual samples of plaque fluid and saliva from irradiated and control monkeys receiving the same cariogenic diet. Plaque and saliva were collected from fasting, tranquillised animals. Four irradiated animals were sampled repeatedly as were non-irradiated controls. Total protein, albumin, immunoglobulins A, G, and M, and the third component of complement (C'3) were quantitated in plaque fluid and whole saliva. Salivary amylase and peroxidase activities were also determined. Plaque fluid and saliva samples were also subjected to polyacrylamide gel electrophoresis. The total viable anaerobic count and numbers of Streptococcus mutans were determined in samples of plaque. The results suggest that the major effect of irradiation leading to increased numbers of S. mutans and caries susceptibility is in the amount, and not the composition, of the saliva produced by the residual gland tissue. The scanty flow of saliva may reduce the effectiveness of cleansing, buffering and lubrication mechanisms as well as resulting in a marked reduction in the total amount of specific and non-specific immune factors entering the mouth.

  8. Urinary estrogen excretion and concentration of serum human placental lactogen in pregnancies following legally induced abortion

    DEFF Research Database (Denmark)

    Obel, E B; Madsen, Mette

    1980-01-01

    Feto-placental function was assessed by 24-hour excretion of estrogen in urine and by the concentration of human Placental Lactogen (hPL) in serum in pregnant women whose previous pregnancy was terminated by legally induced abortion. The mean 24-hour excretion of estrogens in urine and the mean...... an increased frequency of dysfunction of the feto-placental unit during the last part of pregnancy in women with previous legally induced abortion. These findings indicate that legal abortion does not seem to increase the frequency of retarded intrauterine growth in a subsequent pregnancy....... concentration of hPL in serum were no lower in this group than in women without previous induced abortion. Neither was the frequency of a low 24-hour excretion of estrogens in urine or low concentration of hPL in serum (values less than mean - 1.96 s) found to be increased. This study could not demonstrate...

  9. Proteinuria: The diagnostic strategy based on urine proteins differentiation

    Directory of Open Access Journals (Sweden)

    Stojimirović Biljana B.

    2004-01-01

    Full Text Available Basal glomerular membrane represents mechanical and electrical barrier for passing of the plasma proteins. Mechanical barrier is composed of cylindrical pores and filtration fissure, and negative layer charge in exterior and interior side of basal glomerular membrane, made of heparan sulphate and sialoglicoproteine, provides certain electrical barrier. Diagnostic strategy based on different serum and urine proteins enables the differentiation of various types of proteinuria. Depending on etiology of proteinuria it can be prerenal, renal and postrenal. By analyzing albumin, armicroglobulin, immunoglobulin G and armacroglobulin, together with total protein in urine, it is possible to detect and differentiate causes of prerenal, renal (glomerular, tubular, glomerulo-tubular and postrenal proteinuria. The adequate and early differentiation of proteinuria type is of an immense diagnostic and therapeutic importance.

  10. Microbial Community Profiling of Human Saliva Using Shotgun Metagenomic Sequencing

    OpenAIRE

    Hasan, Nur A.; Young, Brian A.; Minard-Smith, Angela T.; Saeed, Kelly; Li, Huai; Heizer, Esley M.; McMillan, Nancy J.; Isom, Richard; Abdullah, Abdul Shakur; Bornman, Daniel M.; Faith, Seth A.; Choi, Seon Young; Dickens, Michael L.; Cebula, Thomas A.; Colwell, Rita R.

    2014-01-01

    Human saliva is clinically informative of both oral and general health. Since next generation shotgun sequencing (NGS) is now widely used to identify and quantify bacteria, we investigated the bacterial flora of saliva microbiomes of two healthy volunteers and five datasets from the Human Microbiome Project, along with a control dataset containing short NGS reads from bacterial species representative of the bacterial flora of human saliva. GENIUS, a system designed to identify and quantify ba...

  11. Myoglobin urine test

    Science.gov (United States)

    Urine myoglobin; Heart attack - myoglobin urine test; Myositis - myoglobin urine test; Rhabdomyolysis - myoglobin urine test ... The test involves only normal urination, which should cause no discomfort.

  12. The association between saliva control, silent saliva penetration, aspiration, and videofluoroscopic findings in Parkinson′s disease patients

    Directory of Open Access Journals (Sweden)

    Ali Rajaei

    2015-01-01

    Full Text Available Background: Dysphagia is a common disorder among patients with Parkinson′s disease (PD. It occurs in up to 80% of all (PD patients during the early stages of the disease and up to 95% in the advanced stages; but professionals may not hear from the patients about dysphagia symptoms until these symptoms reach an advanced stage and lead to medical complications. Materials and Methods: Thirty-three PD patients (mean age 66.09 ± 9.4 years; 24 men, nine women participated in this study at our Neurology Institute, between April 20, 2013, and October 26, 2013. They were asked two questions; one about saliva control and the other about silent saliva penetration and aspiration. Next, they underwent the videofluoroscopic swallowing study (VFSS. Results: The Pearson Correlation coefficient between the Penetration-Aspiration Scale (PAS scores and question 1 scores was 0.48 (P < 0.05, =0.25, and there was a significant correlation between the PAS scores and question 2 scores, and also question 1 scores + question 2 scores (r = 0.589, P < 0.05, =0 and r = 0589, P < 0.05, =0. Conclusions: This study showed a significant correlation between the questions about saliva control, silent saliva penetration, and aspiration, and laryngeal penetration and aspiration during VFSS. Therefore, by using these two questions, the potential silent laryngeal penetration and aspiration during meals could be detected before it led to aspiration pneumonia. Taking the benefit of these questions, as a part of the swallowing assessment of PD patients, is recommended.

  13. Effects of Lactobacillus rhamnosus GG on saliva-derived microcosms

    NARCIS (Netherlands)

    Pham, L.C.; Hoogenkamp, M.A.; Exterkate, R.A.M.; Terefework, Z.; de Soet, J.J.; ten Cate, J.M.; Crielaard, W.; Zaura, E.

    2011-01-01

    Objective The probiotic strain Lactobacillus rhamnosus GG (LGG) is shown to hamper the presence of mutans streptococci in saliva and may have positive effects on oral health. We investigated the effects of LGG on the cariogenic potential and microbial composition of saliva-derived microcosms. Design

  14. The role of electrostatics in saliva-induced emulsion flocculation

    NARCIS (Netherlands)

    Silletti, Erika; Vingerhoeds, Monique H.; Norde, Willem; Van Aken, George A.

    Upon consumption food emulsions undergo different processes, including mixing with saliva. It has been shown that whole saliva induces emulsion flocculation [van Aken, G. A., Vingerhoeds, M. H., & de Hoog, E. H. A. (2005). Colloidal behaviour of food emulsions under oral conditions. In E. Dickinson

  15. Assessing genetic polymorphisms using DNA extracted from cells present in saliva samples

    Directory of Open Access Journals (Sweden)

    Nemoda Zsofia

    2011-12-01

    Full Text Available Abstract Background Technical advances following the Human Genome Project revealed that high-quality and -quantity DNA may be obtained from whole saliva samples. However, usability of previously collected samples and the effects of environmental conditions on the samples during collection have not been assessed in detail. In five studies we document the effects of sample volume, handling and storage conditions, type of collection device, and oral sampling location, on quantity, quality, and genetic assessment of DNA extracted from cells present in saliva. Methods Saliva samples were collected from ten adults in each study. Saliva volumes from .10-1.0 ml, different saliva collection devices, sampling locations in the mouth, room temperature storage, and multiple freeze-thaw cycles were tested. One representative single nucleotide polymorphism (SNP in the catechol-0-methyltransferase gene (COMT rs4680 and one representative variable number of tandem repeats (VNTR in the serotonin transporter gene (5-HTTLPR: serotonin transporter linked polymorphic region were selected for genetic analyses. Results The smallest tested whole saliva volume of .10 ml yielded, on average, 1.43 ± .77 μg DNA and gave accurate genotype calls in both genetic analyses. The usage of collection devices reduced the amount of DNA extracted from the saliva filtrates compared to the whole saliva sample, as 54-92% of the DNA was retained on the device. An "adhered cell" extraction enabled recovery of this DNA and provided good quality and quantity DNA. The DNA from both the saliva filtrates and the adhered cell recovery provided accurate genotype calls. The effects of storage at room temperature (up to 5 days, repeated freeze-thaw cycles (up to 6 cycles, and oral sampling location on DNA extraction and on genetic analysis from saliva were negligible. Conclusions Whole saliva samples with volumes of at least .10 ml were sufficient to extract good quality and quantity DNA. Using

  16. Ketones urine test

    Science.gov (United States)

    Ketone bodies - urine; Urine ketones; Ketoacidosis - urine ketones test; Diabetic ketoacidosis - urine ketones test ... Urine ketones are usually measured as a "spot test." This is available in a test kit that ...

  17. Bacterial profiles of saliva in relation to diet, lifestyle factors, and socioeconomic status

    DEFF Research Database (Denmark)

    Belstrøm, Daniel; Holmstrup, Palle; Nielsen, Claus H

    2014-01-01

    BACKGROUND AND OBJECTIVE: The bacterial profile of saliva is composed of bacteria from different oral surfaces. The objective of this study was to determine whether different diet intake, lifestyle, or socioeconomic status is associated with characteristic bacterial saliva profiles. DESIGN: Stimu...... of saliva. CONCLUSIONS: The bacterial profile of saliva seems independent of diet intake, but influenced by smoking and maybe socioeconomic status.......BACKGROUND AND OBJECTIVE: The bacterial profile of saliva is composed of bacteria from different oral surfaces. The objective of this study was to determine whether different diet intake, lifestyle, or socioeconomic status is associated with characteristic bacterial saliva profiles. DESIGN...... presence and levels (mean HOMIM-value) of bacterial probes as endpoints, the influence of diet intake, lifestyle, and socioeconomic status on the bacterial saliva profile was analyzed by Mann-Whitney tests with Benjamini-Hochberg's correction for multiple comparisons and principal component analysis...

  18. Cultural, behavioral, social, and psychological perceptions of saliva: relevance to clinical diagnostics.

    Science.gov (United States)

    Nguyen, Sean; Wong, David T

    2006-04-01

    The search for a resource that can be used to detect a broad range of diseases easily and reliably is akin to a search for the diagnostic Holy Grail. Yet, each of us may have inside our mouths, a key to the pathological and disease biomarker library hidden inside our bodies. Saliva--the source of all this information--is the secretory product of glands located in or around the oral cavity. If one could read the stories of diagnostic information present within saliva, then the abundance of information waiting to be found could be comparable to a vast vault of information, such as the Internet. Upon dissection of this data, it would be seen that the source of this information is from saliva's origin as a filtrate of blood, and that the validity of both mediums should be equal. Although one day this may be the view, most people's hold of saliva, current and past cultures, have fared much more diverse meanings to the secretion. Ivan Pavlov's experiments has shown how closely tied salivation is with the thought of food, one of life's primary indulgences. The relationship between salivation and behaviors within our daily lives is undeniable. Yet most people never appreciate the uniqueness of saliva. Throughout the world, saliva carries definite positive and negative connotations, based upon its social, psychological, behavioral, and cultural settings. The thought of saliva may be viewed as grotesque in one population, yet may be the vehicle of blessing in other cultures. Saliva's double nature brings up some interesting cultural, social, behavioral, and psychological points about how saliva is perceived in the world, some of which are subsequently stated in order to present saliva as the spirited fluid it is.

  19. [Estimation of mercury in the urine of cigarette smokers].

    Science.gov (United States)

    Kulikowska-Karpińska, Elżbieta; Zdanowicz, Magdalena; Gałażyn-Sidorczuk, Małgorzata

    Cigarette smoking is one of the most common habits of the modern world. According to a NATPOL PLU study, every third adult Pole is dependent on nicotine. Tobacco smoke contains about 5,000 components, of which over 1,000 are very toxic chemical substances (3,4-benzopyrene, heavy metals, free radicals, hydrogen cyanide, nitrogen oxides and N-nitrosamines). Exposure to tobacco smoke is an example of a complex, with a significant number of interactions. To assess the concentration of copper in the urine of smokers. Based on the results, an attempt was made to determine whether smoking can affect the level of copper in the body. The study involved 170 healthy volunteers, 99 smokers and 71 non-smokers (control group). The age of patients in both groups were in the range of 20-60 years. The mean age for men and women was 41 years. The average length of cigarette smoking was 18 years for women and 21 years for men, and the number of cigarettes smoked 1-40 ⁄ 24. The urine concentrations of Cu were determined by atomic absorption spectrometry (AAS) and serum creatinine kinetic method using a set of BIOLAB. Cu concentration in urine was expressed in mg / g creatinine. Smokers were found to have reduced levels of copper in the urine, depending on sex, age and brand of cigarettes. In male smokers, copper concentration in the urine was dependent on age and time of smoking, whereas among women this relationship was not observed. Cigarette smoking significantly influences the level of copper in the urine. Both female and male smokers showed reduced levels of copper in the urine, which may indicate its increased accumulation in the body. Excessive accumulation of copper is very dangerous since it may exhibit toxic effects towards many organs and systems.

  20. Changes in Cytokines and Aggrecan ARGS Neoepitope in Synovial Fluid and Serum and in C-Terminal Crosslinking Telopeptide of Type II Collagen and N-Terminal Crosslinking Telopeptide of Type I Collagen in Urine Over Five Years After Anterior Cruciate Ligament Rupture

    DEFF Research Database (Denmark)

    Struglics, André; Larsson, Staffan; Kumahashi, Nobuyuki

    2015-01-01

    OBJECTIVE: To prospectively monitor levels of proinflammatory cytokines and aggrecan ARGS neoepitope in synovial fluid and serum as well as levels of C-terminal crosslinking telopeptide of type II collagen (CTX-II) and N-terminal crosslinking telopeptide of type I collagen (NTX-I) in urine after ...

  1. CORRELATION OF SPOT URINE ALBUMIN AND 12-HOUR URINE PROTEIN WITH 24-HOUR URINE PROTEIN IN PRE-ECLAMPSIA

    Directory of Open Access Journals (Sweden)

    S. Vinayachandran

    2017-11-01

    Full Text Available BACKGROUND Pre-eclampsia is defined as the development of new-onset hypertension in the second half of pregnancy often accompanied by new-onset proteinuria with other signs and symptoms. Proteinuria is defined by the excretion of 300 mg or more of protein in a 24-hour urine collection. To avoid time consumed in collection of 24-hour urine specimens, efforts have been made to develop faster methods to determine concentration of urine protein. Preliminary studies have suggested that 12-hour urine protein collection maybe adequate for evaluation of pre-eclampsia with advantage of early diagnosis and treatment of pre-eclampsia as well as potential for early hospital discharge and increased compliance with specimen collection. The aim of the study is to evaluate and correlate spot urine albumin and 12-hour urine protein with 24-hour urine protein in pre-eclampsia. MATERIALS AND METHODS A diagnostic evaluation study- a 24-hour urine protein, 12-hour urine protein and spot urine albumin results are analysed. Correlation of 12-hour urine protein and spot urine albumin with 24-hour urine protein is analysed using SPSS software. The strength of correlation was measured by Pearson’s correlation coefficient (r. Student’s t-test and Chi-square tests were used to compare patients with and without 24-hour urine protein ≥300 mg. Probability value of 165 mg with 24-hour urine protein ≥300 mg suggest that this test has role in the evaluation of women with suspected pre-eclampsia and could be substituted for 24-hour urine protein as a simple, faster and cheaper method.

  2. Zinc in human serum

    International Nuclear Information System (INIS)

    Kiilerich, S.

    1987-01-01

    The zinc ion is essential for the living organism. Many pathological conditions have been described as a consequence of zinc deficiency. As zinc constitutes less than 0.01 per cent of the body weight, it conventionally belongs to the group of trace elements. The method of atomic absorption spectrophotometry is used to measure the concentration of zinc in serum and urine from healthy persons. The assumptions of the method is discussed. The importance of proteinbinding, diet and the diurnal variation of serum zinc concentration is presented. Serum versus plasma zinc concentration is discussed. Reference serum zinc values from 104 normal subjects are given. Zinc in serum is almost entirely bound to proteins. A preliminary model for the estimation of the distribution of zinc between serum albumin and α 2 -macroglobulin is set up. This estimate has been examined by an ultracentrufugation method. The binding of zinc to a α 2 -macroglobulin in normal persons is appoximately 7 per cent, in patients with cirrhosis of the liver of alcoholic origin approximately 6 per cent, in patients with insulin dependent diabetes mellitus approximately 5 per cent, and in patients with chronic renal failure approximately 2 per cent. It is concluded, therefore, that for clinical purposes it is sufficient to use the concentration of total serum zinc corrected for the concentration of serum albumin. (author)

  3. The relationship between body iron stores and blood and urine cadmium concentrations in US never-smoking, non-pregnant women aged 20-49 years

    International Nuclear Information System (INIS)

    Gallagher, Carolyn M.; Chen, John J.; Kovach, John S.

    2011-01-01

    Background: Cadmium is a ubiquitous environmental pollutant associated with increased risk of leading causes of mortality and morbidity in women, including breast cancer and osteoporosis. Iron deficiency increases absorption of dietary cadmium, rendering women, who tend to have lower iron stores than men, more susceptible to cadmium uptake. We used body iron, a measure that incorporates both serum ferritin and soluble transferrin receptor, as recommended by the World Health Organization, to evaluate the relationships between iron status and urine and blood cadmium. Methods: Serum ferritin, soluble transferrin receptor, urine and blood cadmium values in never-smoking, non-pregnant, non-lactating, non-menopausal women aged 20-49 years (n=599) were obtained from the 2003-2008 National Health and Nutrition Examination Surveys. Body iron was calculated from serum ferritin and soluble transferrin receptor, and iron deficiency defined as body iron <0 mg/kg. Robust linear regression was used to evaluate the relationships between body iron and blood and urine cadmium, adjusted for age, race, poverty, body mass index, and parity. Results: Per incremental (mg/kg) increase in body iron, urine cadmium decreased by 0.003 μg/g creatinine and blood cadmium decreased by 0.014 μg/L. Iron deficiency was associated with 0.044 μg/g creatinine greater urine cadmium (95% CI=0.020, 0.069) and 0.162 μg/L greater blood cadmium (95% CI=0.132, 0.193). Conclusions: Iron deficiency is a risk factor for increased blood and urine cadmium among never-smoking, pre-menopausal, non-pregnant US women, independent of age, race, poverty, body mass index and parity. Expanding programs to detect and correct iron deficiency among non-pregnant women merits consideration as a potential means to reduce the risk of cadmium associated diseases. - Highlights: → Body iron was calculated from serum ferritin and soluble transferrin receptor. → Body iron was inversely associated with blood and urine cadmium

  4. The relationship between body iron stores and blood and urine cadmium concentrations in US never-smoking, non-pregnant women aged 20-49 years

    Energy Technology Data Exchange (ETDEWEB)

    Gallagher, Carolyn M., E-mail: 2crgallagher@optonline.net [PhD Program in Population Health and Clinical Outcomes Research, Stony Brook University, NY (United States) and Department of Preventive Medicine, Stony Brook University, Z-8036, Level 3, HSC, Stony Brook, NY 11794-8036 (United States); Chen, John J.; Kovach, John S. [Department of Preventive Medicine, Stony Brook University, Z-8036, Level 3, HSC, Stony Brook, NY 11794-8036 (United States)

    2011-07-15

    Background: Cadmium is a ubiquitous environmental pollutant associated with increased risk of leading causes of mortality and morbidity in women, including breast cancer and osteoporosis. Iron deficiency increases absorption of dietary cadmium, rendering women, who tend to have lower iron stores than men, more susceptible to cadmium uptake. We used body iron, a measure that incorporates both serum ferritin and soluble transferrin receptor, as recommended by the World Health Organization, to evaluate the relationships between iron status and urine and blood cadmium. Methods: Serum ferritin, soluble transferrin receptor, urine and blood cadmium values in never-smoking, non-pregnant, non-lactating, non-menopausal women aged 20-49 years (n=599) were obtained from the 2003-2008 National Health and Nutrition Examination Surveys. Body iron was calculated from serum ferritin and soluble transferrin receptor, and iron deficiency defined as body iron <0 mg/kg. Robust linear regression was used to evaluate the relationships between body iron and blood and urine cadmium, adjusted for age, race, poverty, body mass index, and parity. Results: Per incremental (mg/kg) increase in body iron, urine cadmium decreased by 0.003 {mu}g/g creatinine and blood cadmium decreased by 0.014 {mu}g/L. Iron deficiency was associated with 0.044 {mu}g/g creatinine greater urine cadmium (95% CI=0.020, 0.069) and 0.162 {mu}g/L greater blood cadmium (95% CI=0.132, 0.193). Conclusions: Iron deficiency is a risk factor for increased blood and urine cadmium among never-smoking, pre-menopausal, non-pregnant US women, independent of age, race, poverty, body mass index and parity. Expanding programs to detect and correct iron deficiency among non-pregnant women merits consideration as a potential means to reduce the risk of cadmium associated diseases. - Highlights: {yields} Body iron was calculated from serum ferritin and soluble transferrin receptor. {yields} Body iron was inversely associated with blood

  5. Comparative evaluation of qigong on various parameters of saliva

    Directory of Open Access Journals (Sweden)

    Bayat Movahed S.

    2007-05-01

    Full Text Available Background and Aim: Qigong is a type of Chinese psychosomatic exercise that integrates meditation, slow physical movements, and breathing. Numerous physical and mental benefits have been classically ascribed to qigong. On the other hand, unstimulated saliva is thought to play an important role in oral immunity, enamel stability and moisturizing the oral mucous membrane. Impaired salivary secretion leads to dental caries, mucosal deterioration and mouth dryness. The aim of the present study was to analyze the effect of a qigong program on various parameters of saliva such as quantity of unstimulated saliva, pH and SIgA. Materials and Methods: Twenty three subjects participated in this clinical trial study. The experimental subjects underwent a qigong training program, conducted by a qualified instructor. The program consisted of half an hour daily practice for 6 months (spring and winter. Saliva was collected in two periods: once during the spring before the experiment commencement and the second, in the following spring. During each period saliva collection was done on tuesday of each week. pH and quantity of salvia measurements were taken simultaneously. SIgA measurements were also taken based on the values obtained in the last phase of the experiment at the end of each spring. The results were analyzed using paired sample T test, one way repeated measure and Bon Ferroni multiple comparison. P<0.05 was the level of significance. Results: Based on our findings, the change in the amount of unstimulated salvia as well as SIgA was statistically significant (P<0.001; however, there was no significant difference in pH values before and after experiment. Conclusion: These findings demonstrate that after 6 months of practicing qigong, significant changes in amount of unstimulated saliva and SIgA occurred in participants. The authors suggest that qigong may be a beneficial adjunctive treatment that enhances amount of unstimulated saliva and SIgA.

  6. Urine β2 Microglobulin and other Biochemical Indices in β Thalassemia Major

    Directory of Open Access Journals (Sweden)

    Yazdan Ghandi

    2009-12-01

    Full Text Available To find if some indices have predictive value for renal complications. We conducted a cross sectional and included 80 patients with the age ranged 5-17 years, all with the proven diagnosis of β-thalassemia major. A urine and 5 ml of blood sample were obtained from all of the cases. Biochemical indices such as serum levels of creatinine, Na, Mg, Hb, and ferritin and also urine levels of Na, Mg, creatinine and β2 microglobulin was measured. All data analysis was performed using SPSS 14.0. P-Spearman test was applied to assess correlation between urine beta-2-microglobulin and other variables. Patients GFR was in normal range. Abnormal level of urine β2 microglobulin was reported in 44 patients (55%. P Spearman test proved correlation only between urine β2 microglobulin and FE-Mg. We concluded that renal proximal tubular dysfunction may oocur in children with β thalassemia major without clinical manifestations of renal dysfunction or decrease in GFR. We warn not to rely only on GFR as a early indicator for renal complications among children with β thalassemia major.

  7. Automated color classification of urine dipstick image in urine examination

    Science.gov (United States)

    Rahmat, R. F.; Royananda; Muchtar, M. A.; Taqiuddin, R.; Adnan, S.; Anugrahwaty, R.; Budiarto, R.

    2018-03-01

    Urine examination using urine dipstick has long been used to determine the health status of a person. The economical and convenient use of urine dipstick is one of the reasons urine dipstick is still used to check people health status. The real-life implementation of urine dipstick is done manually, in general, that is by comparing it with the reference color visually. This resulted perception differences in the color reading of the examination results. In this research, authors used a scanner to obtain the urine dipstick color image. The use of scanner can be one of the solutions in reading the result of urine dipstick because the light produced is consistent. A method is required to overcome the problems of urine dipstick color matching and the test reference color that have been conducted manually. The method proposed by authors is Euclidean Distance, Otsu along with RGB color feature extraction method to match the colors on the urine dipstick with the standard reference color of urine examination. The result shows that the proposed approach was able to classify the colors on a urine dipstick with an accuracy of 95.45%. The accuracy of color classification on urine dipstick against the standard reference color is influenced by the level of scanner resolution used, the higher the scanner resolution level, the higher the accuracy.

  8. Effects of isoflurane anesthesia and pilocarpine on rat parotid saliva flow

    DEFF Research Database (Denmark)

    Knudsen, Jacob Dronninglund; Nauntofte, Birgitte; Josipovic, M

    2011-01-01

    The purpose of this study was to investigate the effects of isoflurane on unstimulated and pilocarpine-stimulated parotid saliva secretion. Ten male Sprague-Dawley rats weighing 350-400 g were randomized into two groups, and the saliva flow rate and lag phase were measured at two doses of isoflur......The purpose of this study was to investigate the effects of isoflurane on unstimulated and pilocarpine-stimulated parotid saliva secretion. Ten male Sprague-Dawley rats weighing 350-400 g were randomized into two groups, and the saliva flow rate and lag phase were measured at two doses...... of isoflurane in a crossover study design. Increasing the isoflurane concentration from 1% to 2% was associated with a 19% decrease in saliva secretion rate, and the lag to saliva secretion was increased by 155%. To clarify whether the effect of isoflurane (1.5%) on the parotid flow varied with stimulus...... intensity, we measured the parotid flow induced by seven different doses of pilocarpine on sham-irradiated rats and rats irradiated with single doses of 15 Gy. A maximal pilocarpine response was obtained with 1.5 mg/kg in both irradiated and sham-irradiated rats; however, the parotid flow of the irradiated...

  9. Radioimmunological determination of chloramphenicol in the saliva of lactating cows

    International Nuclear Information System (INIS)

    Dotter, A.; Kroker, R.; Arnold, D.; Somogyi, A.

    1987-01-01

    In an effort to search for noninvasive methods suitable to monitor compliance with the ban of chloramphenicol (CAP) in milkproducing animals, the pharmacokinetic behavior of this drug in bovine saliva was investigated. As revealed by studies using a radioimmunological assay, CAP appears following its intracisternal (i.c.) or subcutaneous (s.c.) administration in the saliva of lactating cows. The level of sensitivity of the method (1.5 ng CAP per g saliva) was reached 14 and 18 days after i.c. and s.c. administration, respectively. At present, the question must remain open as to whether the concentration of CAP in the saliva can serve as a reliable indicator for the enforcement of the highest permissible level set at 1 ng CAP per g of milk by German regulations. (orig.) [de

  10. Radioimmunological determination of chloramphenicol in the saliva of lactating cows

    Energy Technology Data Exchange (ETDEWEB)

    Dotter, A.; Kroker, R.; Arnold, D.; Somogyi, A.

    1987-02-01

    In an effort to search for noninvasive methods suitable to monitor compliance with the ban of chloramphenicol (CAP) in milk-producing animals, the pharmacokinetic behavior of this drug in bovine saliva was investigated. As revealed by studies using a radioimmunological assay, CAP appears following its intracisternal (i.c.) or subcutaneous (s.c.) administration in the saliva of lactating cows. The level of sensitivity of the method (1.5 ng CAP per g saliva) was reached 14 and 18 days after i.c. and s.c. administration, respectively. At present, the question must remain open as to whether the concentration of CAP in the saliva can serve as a reliable indicator for the enforcement of the highest permissible level set at 1 ng CAP per g of milk by German regulations.

  11. Laboratory test for 18 imported Zika cases in China%中国18例输入性寨卡病毒感染者实验室检测结果分析

    Institute of Scientific and Technical Information of China (English)

    吴德; 张欢; 谈琦琪; 孙九峰; 周惠琼; 宁丹; 管大伟

    2016-01-01

    目的:了解寨卡病例的排毒途径和时间,为寨卡病例的实验检测提供科学依据。方法收集寨卡病例不同时间的多类临床样本,用real-time RT-PCR方法对其进行核酸检测,阳性标本进行乳鼠颅内和细胞接种分离寨卡病毒,将获得的寨卡病毒利用二代测序方法进行全基因组测序,所测得的序列与GenBank中寨卡序列进行系统进化分析。结果18例感染者尿液、唾液和血清样本中寨卡病毒核酸阳性率分别为82.4%(14/17)、82.4%(14/17)和52.9%(9/17),尿液排毒的持续时间最长,其次是唾液和血液。9份阳性血清标本共分离到6株寨卡病毒,进化分析6条寨卡基因组序列均属于亚洲族系,来自萨摩亚与委内瑞拉的病毒位于不同的进化分支中。结论唾液、血清和尿液均可用于寨卡病例的日常检测,尿液和唾液的核酸检测率更高,阳性血清更容易分离到寨卡病毒。乳鼠和细胞均可用于寨卡病毒的分离,但乳鼠颅内接种的病毒分离率更高。%Objective To provide scientific evidences for Zika virus detection by clarifying the means by which Zika virus was discharged and the duration of corresponding processes. Methods Various samples of Zika cases were collected at different times and detected by using real-time RT-PCR. The positive samples were inoculated into cells and suckling mice through intracranial injection. The whole genome se-quences of those isolated Zika virus strain were sequenced and the results were further analyzed by comparing with the sequences of Zika virus from GenBank. Results The positive rates of Zika virus in urine, saliva and serum samples were 82. 4% (14/17), 82. 4% (14/17) and 52. 9% (9/17) respectively. The longest period of detected presence of Zika virus was found in urine samples amongst the three types of samples, fol-lowed by saliva and serum samples. Six Zika virus strains were isolated from 9 positive serum samples. Phy

  12. Urine cup for collection of urine from cows.

    Science.gov (United States)

    Fellner, V; Weiss, M F; Belo, A T; Belyea, R L; Martz, F A; Orma, A H

    1988-08-01

    A urine cup for continuous and complete collection of urine from cows was constructed from Plastisol, cotton webb strapping, Velcro Brand touch fasteners [corrected], snap-fasteners, denim patches, weather stripping, and vacuum hose. The urine cup was made from Plastisol using a heated lead mold. It was large enough to enclose a 9 cm x 6 cm area around the vulva of a cow and was attached by strapping and Velcro Brand touch fasteners [corrected] to patches glued to the rump. Urine cups were used repeatedly and provided for long-term collection of urine from cows, eliminating the need for indwelling catheters. Applications include long-term nutrient balance, radioisotope, and metabolism studies.

  13. Autologous saliva transfusion: treatment for HIV?

    Science.gov (United States)

    Arakeri, Gururaj

    2010-05-01

    The HIV-1 pandemic is a complex mix of diverse epidemics within and between countries and regions of the world, and is undoubtedly the defining public-health crisis of our time. Any therapeutic or prophylactic measure which holds promise or provides clues of eliminating or inhibiting the infection is worthy of investigation. As our body's own saliva is suspiciously escaping from the infection and providing clues regarding the resistance/inhibition of HIV; in this paper, a treatment approach is suggested with the rationale of in vitro effective antiviral action of autogenous saliva may also have a better therapeutic potential by its intravenous administration along with dextran.

  14. Radioimmunoassay of triiodothyronine in urine

    International Nuclear Information System (INIS)

    Kosowicz, J.; Gembicki, M.; Schneider, E.; Eder, M.

    1977-01-01

    In 21 cases of hypothyroidism, in 39 cases of hyperthyroidism, in 54 healthy subjects, in 23 pregnant women, and in certain internal diseases determinations of triiodothyronine were carried out in urine by radioimmunoassay. Anti-T 3 antibodies were obtained in rabbits and sheep immunized with a complex of bovine albumin with triiodothyronine ester. Labelled triiodothyronine of high specific activity was obtained by iodinating triodothyronine by the chloramine method. Determinations of triiodothyronine were performed in morning urine and the obtained values were calculated for one-hour excretion. In healthy subjects the excretion of T 3 was from 20 to 95 ng/hour, in hyperthyroidism it was significantly raised to from 120 to over 600 ng/hour, while in most cases of hypothyroidism it was decreased. In pregnancy the urinary excretion of T 3 was normal amounting to from 34 to 87 ng/hour, although in most cases the serum T 3 concentration was raised. In cases of anorexia nervosa and in obese starving subjects the excretion of T 3 fell significantly, and similarly low excretion was found in some cases of debilitating diseases and myocardial infarction. (author)

  15. Interference by p--hydroxyphenobarbital in the 125I--radioimmunoassay of serum and urinary phenobarbital

    International Nuclear Information System (INIS)

    Viswanathan, C.T.; Booker, H.E.; Welling, P.G.

    1977-01-01

    A radioimmunoassay for barbiturates is shown to be equally sensitive to phenobarbital and its major urinary metabolite, p-hydroxyphenobarbital, in serum and urine. Interference by the metabolite can be essentially eliminated by selectively extracting phenobarbital into chloroform. The extraction efficiency of the method for phenobarbital was 93 +- 2 percent (SD) over the concentration range studied. Although cross reactivity between barbiturates and their metabolites may be less important in determining cases of barbiturates abuse or overdose, it may be extremely important if data on serum or urine are required for accurate estimates of drug disposition, or in establishing dose/response relationships

  16. Patients with dental calculus have increased saliva and gingival crevicular fluid fetuin-A levels but no association with fetuin-A polymorphisms

    OpenAIRE

    DOĞAN, Gülnihal Emrem; DEMİR, Turgut; LALOĞLU, Esra; SAĞLAM, Ebru; AKSOY, Hülya; YILDIRIM, Abdulkadir; AKÇAY, Fatih

    2016-01-01

    ABSTRACT: Fetuin-A is a potent inhibitor of calcium-phosphate precipitation and of the calcification process, therefore it can also be related with dental calculus. Thus, we aimed to investigate a possible relationship between fetuin-A gene polymorphism and the presence of dental calculus. A possible relationship between serum, saliva and gingival crevicular fluid (GCF) levels of fetuin-A was also investigated. Fetuin-A c.742C > T and c.766C > G polymorphisms were investigated in 103 patients...

  17. Saliva in relation to dental erosion before and after radiotherapy

    DEFF Research Database (Denmark)

    Jensdottir, Thorbjorg; von Buchwald, Christian; Nauntofte, Birgitte

    2013-01-01

    Abstract Objective. Low saliva flow and abnormal saliva composition are common conditions after radiotherapy for oral cavity and pharyngeal cancer. Both conditions increase the susceptibility to dental caries and erosion, which may be further accelerated by changes in food preferences. The aim...... of this study was to determine changes in saliva flow and susceptibility to erosive challenges in pharyngeal cancer patients before and after radiotherapy to the head and neck. Materials and methods: The erosive potential of sucking acidic candies with and without calcium was determined in nine patients (50...

  18. Effect of immobilization on urine calcium excretion in orthopedic patients with pelvic fracture treated by skin traction.

    Science.gov (United States)

    Derakhshan, Ali; Derakhshan, Nima; Namazi, Hamid; Ghaffarpasand, Fariborz

    2015-03-31

    To determine the effects on urine calcium excretion of immobilization by skin traction in patients with pelvic fracture. In a prospective study, a consecutive series of patients with pelvic fracture treated by skin traction were enrolled. Serum (calcium, phosphorous, alkaline phosphatase, sodium, potassium, uric acid, BUN, creatinine) and fasting urine calcium, creatinine, sodium, potassium and uric acid were checked within 48 hours of hospitalization and at 7, 14 and 21 days of immobilization and then after 3 months of mobilization. Trends in changes of variables were recorded. Fifty five patients were enrolled in this study; they were 45 (81.8%) males and 10 (18.2%) females with a mean age 19.4 ± 12.7 years. We found that serum levels of calcium (p = 0.004), phosphorous (p = 0.047) and alkaline phosphatase (p = 0.001) increased significantly during the 3 weeks of immobilization. In the same way, urine calcium/ urine creatinine ratio increased significantly in the study period (p = 0.004). No symptomatic renal stone formation was observed during the study period. Immobilization even in short term causes hypercalciuria in orthopedic patients. Although it is transient and improves with subsequent mobilization, it is needed to be considered specifically by the team caring for this group of patients.

  19. Isolation and Analytical Characterization of Local Malaysian Leech Saliva

    Directory of Open Access Journals (Sweden)

    Mohamed Alaama

    2011-12-01

    Full Text Available Leech saliva contains biologically active compounds that are mainly proteins and peptides. In this study a modified and smooth extraction method of saliva was used without leeches' scarification. UV and Bradford Assay protein methods showed that the saliva extract contains high concentrations of proteins. RP-HPLC chromatogram revealed that more than 30 different peaks were observed in leech saliva extract. Gel electrophoresis revealed the existence of proteins and peptides with different molecular weights. The gel showed up to 25 different bands. Comparison of gel electrophoresis data with protein database revealed the closeness of four molecular weights to known proteins from Hirudinaria leech family. Other proteins detected by gel electrophoresis may be related to completely new biologically active proteins and peptides in the saliva extract or to a modification (isoforms of the existing ones or finally to a mixture of both.ABSTRAK: Air liur pacat secara biologinya mengandungi sebahagian besar campuran aktif protein dan peptida. Dalam kajian ini, kaedah pengestrakan air liur pacat yang telah diubah suai digunakan tanpa perlu membunuh pacat. Kaedah protein Cerakin UV dan Bradford menunjukkan air liur pacat yang diekstrak mengandungi konsentrasi protein yang tinggi. Kromatogram RP-HPLC memperlihatkan lebih daripada 30 puncak berbeza diperolehi semasa air liur pacat diekstrak. Gel elektroforesis memperlihatkan kewujudan protein dan peptida dengan berat molekul yang berbeza. Gel menunjukkan hingga 25 jalur yang berbeza. Perbandingan data menggunakan gel elektroforesis seiring dengan pangkalan data protein memperlihatkan persamaan empat berat molekul, dengan protein yang yang dikenali daripada keluarga pacat Hirudinaria. Jenis protein lain yang dikesan dengan menggunakan gel elektrofosis mungkin juga berkait secara biologinya dengan protein dan peptida aktif yang baru, dalam ekstrak air liur atau pengubahsuaian (beberapa jenis yang berbeza daripada

  20. Urine culture

    Science.gov (United States)

    Culture and sensitivity - urine ... when urinating. You also may have a urine culture after you have been treated for an infection. ... when bacteria or yeast are found in the culture. This likely means that you have a urinary ...

  1. Urate-Lowering Agents in Asymptomatic Hyperuricemia: Role of Urine Sediment Analysis and Musculoskeletal Ultrasound

    Directory of Open Access Journals (Sweden)

    Davide Viggiano

    2018-04-01

    Full Text Available Current urate-lowering therapy (ULT includes three direct acting drugs (allopurinol, febuxostat, Rasburicase and at least four ‘indirect’ drugs with other important targets (canagliflozin, losartan, fenofibrate and sevelamer. Moreover, the alcalinization of urines using bicarbonate can be used to dissolve urate crystals and the clinician may discontinue several drugs are known to increase serum levels of uric acid, such as diuretics, aspirin, cyclosporine, theophylline, mycophenolate and ACE inhibitors. While there is a consensus to start ULT in cases of symptomatic hyperuricemia (gout, urate-nephrolithiasis, the very frequent conditions of asymptomatic hyperuricemia remains a major conundrum. The effect of asymptomatic hyperuricemia on kidney function has had fluctuating positions over decades. The conflicting results might indicate: (i the presence of counterbalancing positive and negative effects on kidney function of both serum uric acid and urate-lowering agents, (ii the presence of a subpopulation of patients, as yet unidentified, which could truly benefit from a urate-lowering therapy. Therefore, today the treatment of asymptomatic hyperuricemia is not recommended nor excluded by current guidelines. Here we suggest that a possible guide for the treatment of asymptomatic hyperuricemia might be the presence of urate crystals in the urine sediment and/or signs of asymptomatic articular damage by urates, identified by musculo-skeletal ultrasound. Moreover, a watchful analysis of the trend in creatinine/eGFR, proteinuria or urate levels might also guide the clinician. Initiation of ULT and follow-up in cases of asymptomatic hyperuricemia should consider urine sediment analysis, musculoskeletal ultrasound and trends in creatinine, proteinuria and serum urate levels.

  2. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration

    Science.gov (United States)

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    Background The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. Methods During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Results Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples

  3. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration.

    Science.gov (United States)

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. The UPCR in samples with low

  4. A population-based study of how children are exposed to saliva in KwaZulu-Natal Province, South Africa: implications for the spread of saliva-borne pathogens to children

    Science.gov (United States)

    Butler, L. M.; Neilands, T. B.; Mosam, A.; Mzolo, S.; Martin, J. N.

    2014-01-01

    Summary Objectives In sub-Saharan Africa, many viral infections, including Epstein–Barr virus, cytomegalovirus, Kaposi’s sarcoma-associated herpesvirus and hepatitis B are acquired in childhood. While saliva is an important transmission conduit for these viruses, little is known about how saliva is passed to African children. We endeavoured to identify the range and determinants of acts by which African children are exposed to saliva. Methods To identify the range of acts by which African children are exposed to saliva, we conducted focus groups, semi-structured interviews and participant observations in an urban and a rural community in South Africa. To measure the prevalence and determinants of the identified acts, we administered a questionnaire to a population-based sample of caregivers. Results We identified 12 caregiving practices that expose a child’s oral–respiratory mucosa, cutaneous surfaces or anal–rectal mucosa to saliva. Several acts were heretofore not described in the contemporary literature (e.g., caregiver inserting finger lubricated with saliva into child’s rectum to relieve constipation). Among 896 participants in the population-based survey, many of the acts were commonly practised by all respondent types (mothers, fathers, grandmothers and siblings). The most common were premastication of food, sharing sweets and premastication of medicinal plants that are spit onto a child’s body. Conclusions African children are exposed to saliva through a variety of acts, practised by a variety of caregivers, with no single predominant practice. This diversity poses challenges for epidemiologic work seeking to identify specific saliva-passing practices that transmit viruses. Most acts could be replaced by other actions and are theoretically preventable. PMID:20149165

  5. Serum Soluble Fms-Like Tyrosine Kinase 1 (sFlt-1 Predicts the Severity of Acute Pancreatitis

    Directory of Open Access Journals (Sweden)

    Paulina Dumnicka

    2016-12-01

    Full Text Available Organ failure is the most important determinant of the severity of acute pancreatitis (AP. Soluble fms-like tyrosine kinase 1 (sFlt-1 is positively associated with organ failure in sepsis. Our aim was to evaluate the diagnostic utility of automated sFlt-1 measurements for early prediction of AP severity. Adult patients (66 with AP were recruited, including 46 with mild (MAP, 15 with moderately-severe (MSAP and 5 with severe AP (SAP. Serum and urine samples were collected twice. Serum sFlt-1 was measured with automated electrochemiluminescence immunoassay. Serum concentrations of sFlt-1 were significantly higher in patients with MSAP and SAP as compared to MAP. SAP patients had the highest concentrations. At 24 and 48 h, sFlt-1 positively correlated with inflammatory markers (leukocyte count, C-reactive protein, kidney function (creatinine, urea, cystatin C, serum and urine neutrophil gelatinase-associated lipocalin, urine albumin/creatinine ratio, D-dimer and angiopoietin-2. sFlt-1 positively correlated with the bedside index of severity in AP (BISAP score and the duration of hospital stay. Serum sFlt-1 above 139 pg/mL predicted more severe AP (MSAP + SAP. In the early phase of AP, sFlt-1 is positively associated with the severity of AP and predicts organ failure, in particular kidney failure. Serum sFlt-1 may be a practical way to improve early assessment of AP severity.

  6. A Schistosoma haematobium-specific real-time PCR for diagnosis of urogenital schistosomiasis in serum samples of international travelers and migrants.

    Science.gov (United States)

    Cnops, Lieselotte; Soentjens, Patrick; Clerinx, Jan; Van Esbroeck, Marjan

    2013-01-01

    Diagnosis of urogenital schistosomiasis by microscopy and serological tests may be elusive in travelers due to low egg load and the absence of seroconversion upon arrival. There is need for a more sensitive diagnostic test. Therefore, we developed a real-time PCR targeting the Schistosoma haematobium-specific Dra1 sequence. The PCR was evaluated on urine (n = 111), stool (n = 84) and serum samples (n = 135), and one biopsy from travelers and migrants with confirmed or suspected schistosomiasis. PCR revealed a positive result in 7/7 urine samples, 11/11 stool samples and 1/1 biopsy containing S. haematobium eggs as demonstrated by microscopy and in 22/23 serum samples from patients with a parasitological confirmed S. haematobium infection. S. haematobium DNA was additionally detected by PCR in 7 urine, 3 stool and 5 serum samples of patients suspected of having schistosomiasis without egg excretion in urine and feces. None of these suspected patients demonstrated other parasitic infections except one with Blastocystis hominis and Entamoeba cyst in a fecal sample. The PCR was negative in all stool samples containing S. mansoni eggs (n = 21) and in all serum samples of patients with a microscopically confirmed S. mansoni (n = 22), Ascaris lumbricoides (n = 1), Ancylostomidae (n = 1), Strongyloides stercoralis (n = 1) or Trichuris trichuria infection (n = 1). The PCR demonstrated a high specificity, reproducibility and analytical sensitivity (0.5 eggs per gram of feces). The real-time PCR targeting the Dra1 sequence for S. haematobium-specific detection in urine, feces, and particularly serum, is a promising tool to confirm the diagnosis, also during the acute phase of urogenital schistosomiasis.

  7. Dot-ELISA-IgM in saliva for the diagnosis of human leptospirosis using polyester fabric-resin as support (Preliminary Report Dot-ELISA-IgM em saliva para diagnóstico da leptospirose humana, empregando como suporte tecido de poliéster-resina (Nota Prévia

    Directory of Open Access Journals (Sweden)

    Marcos Vinicius da Silva

    1994-10-01

    Full Text Available In order to improve the diagnosis of human leptospirosis, we standardized the dot-ELISA for the search of specific IgM antibodies in saliva. Saliva and serum samples were collected simultaneously from 20 patients with the icterohemorrhagic form of the disease, from 10 patients with other pathologies and from 5 negative controls. Leptospires of serovars icterohaemorrhagiae, canicola, hebdomadis, brasiliensis and cynopteri grown in EMJH medium and mixed together in equal volumes, were used as antigen at individual protein concentration of 0.2 µg/µl. In the solid phase of the test we used polyester fabric impregnated with N-methylolacrylamide resin. The antigen volume for each test was 1µl, the saliva volume was 8 µl, and the volume of peroxidase-labelled anti-human IgM conjugate was 30 µl. A visual reading was taken after development in freshly prepared chromogen solution. In contrast to the classic nitrocellulose membrane support, the fabric support is easy to obtain and to handle. Saliva can be collected directly onto the support, a fact that facilitates the method and reduces the expenses and risks related to blood processing.Com a finalidade de melhorar o diagnóstico da leptospirose humana, padronizou-se o teste dot-ELISA para a pesquisa de anticorpos específicos da classe IgM na saliva. Empregaram-se amostras de saliva e soro coletadas simultaneamente de 20 pacientes com a forma ictero-hemorrágica da doença, de 10 pacientes com outras patologias e 5 controles negativos. Culturas de Leptos-pira em meio EMJH, dos sorovares: icterohaemorrhagiae, canicola, hebdomadis, brasiliensis e cynopteri, foram utilizadas como antígeno, na concentração proteica individual de 0,2 µg/µl, misturadas em volumes iguais. Na fase sólida do teste empregou-se tecido de po-liéster impregnado com resina de N-metilol-acrilamida. O volume do antígeno para cada teste foi de 1µl, o de saliva 8µl, o de conjugado anti-IgM humana marcada com peroxidase, de

  8. Determination of 17-oxosteroid glucuronides and sulfates in urine and serum by fluorescence high-performance liquid chromatography using dansyl hydrazine as a prelabeling reagent.

    Science.gov (United States)

    Kawasaki, T; Maeda, M; Tsuji, A

    1982-12-10

    A fluorescence high-performance liquid chromatographic method is described for the direct determination of conjugated 17-oxosteroids in biological fluids without hydrolysis. Conjugated 17-oxosteroids are extracted with Sep-Pak C18 cartridge, labeled with dansyl hydrazine in trichloroacetic acid--benzene solution and then separated by high-performance liquid chromatography on reversed-phase muBondapak C18 column using 0.01 M sodium acetate in methanol-water-acetic acid (65:35:1, v/v) as the mobile phase. The eluate is monitored by a fluorophotometer at 365 nm (excitation) and 520 nm (emission). Linearities of fluorescence intensities (peak heights) with the amounts of various conjugated 17-oxosteroids were obtained between 10 pmol and 100 pmol. This method is sensitive, reliable and useful for the simultaneous determination of conjugated 17-oxosteroids in urine and serum.

  9. Association between Serum Albumin Concentration and Ketosis Risk in Hospitalized Individuals with Type 2 Diabetes Mellitus.

    Science.gov (United States)

    Cheng, Po-Chung; Hsu, Shang-Ren; Cheng, Yun-Chung

    2016-01-01

    Objective. This study examined the association between serum albumin concentration and ketosis risk in hospitalized individuals with type 2 diabetes mellitus (T2DM). Methods. A retrospective cross-sectional study was conducted at a medical center in Taiwan. Inclusion criteria were endocrinology ward inpatients exceeding 21 years of age, with preexisting diagnosis of T2DM, and blood glucose above 13.9 millimoles per liter (mmol/L) at admission. Individuals without measurement of serum albumin, urine ketone, or hemoglobin A1C, or harboring active infection, myocardial infarction, cerebrovascular event, cirrhosis, malignancy, or overt proteinuria were excluded. Using serum albumin concentration below 3.0 grams per deciliter to define hypoalbuminemia, 151 hypoalbuminemic cases and 104 normoalbuminemic controls were enrolled. The presence of ketones in urine established ketosis. Results. The prevalence of ketonuria was 48% in hypoalbuminemic subjects compared to 30% in normoalbuminemic controls (odds ratio (OR): 2.15; 95% confidence interval (CI): 1.26-3.57; P = 0.004). Moreover, among the 156 subjects with serum beta-hydroxybutyrate measurement in addition to urine ketone, 33% of the hypoalbuminemic individuals had ketonemia exceeding 3 mmol/L compared to 19% of those with normoalbuminemia (OR: 2.12, 95% CI: 0.99-4.48, P = 0.051). Conclusions. Serum albumin concentration is inversely associated with ketosis risk in hospitalized individuals with T2DM.

  10. Metabolic Profiling Analysis of the Alleviation Effect of Treatment with Baicalin on Cinnabar Induced Toxicity in Rats Urine and Serum

    Directory of Open Access Journals (Sweden)

    Guangyue Su

    2017-05-01

    Full Text Available Objectives: Baicalin is the main bioactive flavonoid constituent isolated from Scutellaria baicalensis Georgi. The mechanisms of protection of liver remain unclear. In this study, 1H NMR-based metabonomics approach has been used to investigate the alleviation effect of Baicalin.Method:1H NMR metabolomics analyses of urine and serum from rats, was performed to illuminate the alleviation effect of Baicalin on mineral medicine (cinnabar-induced liver and kidney toxicity.Results: The metabolic profiles of groups receiving Baicalin at a dose of 80 mg/kg were remarkably different from cinnabar, and meanwhile, the level of endogenous metabolites returned to normal compared to group cinnabar. PLS-DA scores plots demonstrated that the variation tendency of control and Baicalein are apart from Cinnabar. The metabolic profiles of group Baicalein were similar to those of group control. Statistics results were confirmed by the histopathological examination and biochemical assay.Conclusion: Baicalin have the alleviation effect to the liver and kidney damage induced by cinnabar. The Baicalin could regulate endogenous metabolites associated with the energy metabolism, choline metabolism, amino acid metabolism, and gut flora.

  11. CHROMOGRANIN A DETECTION IN SALIVA OF TYPE 2 DIABETES PATIENTS

    Directory of Open Access Journals (Sweden)

    Martine Soell

    2010-02-01

    Full Text Available Chromogranin A is present in secretion granules of nerve, endocrine and immune cells and is a precursor of several peptides with antibacterial and antifungal properties at micromolar concentrations.Our aim in this prospective, double blind study, was to determine the expression of chromogranin A and its peptides at protein level in saliva of type 2 diabetic patients and thereby to obtain a new non-invasive diagnostic means for the future.Saliva was taken from 30 type 2 diabetic patients and 30 healthy individuals at the same time interval in the morning without any oral stimuli. Circadianic periodics in protein productions have been avoided. The presence of chromogranin A and its derived peptides was determined in whole saliva, after centrifugation at 40C for 12 min at 14 000 rpm, by SDS-PAGE electrophoresis and Immunoblotting (Western Blot. To ensure same protein concentrations Bradford protein quantification assay has been performed before.For the first time, we have determined an overexpression of chromogranin A in saliva of diabetic patients in 100% of the individuals.Chromogranin A, a circulating biomarker for epithelial tumours, is also overexpressed in saliva of type 2 diabetic patients. To confirm our results, more studies with a large amount of patients is necessary.

  12. Chromogranin A Detection in Saliva of Type 2 Diabetes Patients

    Directory of Open Access Journals (Sweden)

    Martine Soell

    2010-02-01

    Full Text Available Chromogranin A is present in secretion granules of nerve, endocrine and immune cells and is a precursor of several peptides with antibacterial and antifungal properties at micromolar concentrations.Our aim in this prospective, double blind study, was to determine the expression of chromogranin A and its peptides at protein level in saliva of type 2 diabetic patients and thereby to obtain a new non-invasive diagnostic means for the future.Saliva was taken from 30 type 2 diabetic patients and 30 healthy individuals at the same time interval in the morning without any oral stimuli. Circadianic periodics in protein productions have been avoided. The presence of chromogranin A and its derived peptides was determined in whole saliva, after centrifugation at 4°C for 12 min at 14 000 rpm, by SDS-PAGE electrophoresis and Immunoblotting (Western Blot. To ensure same protein concentrations Bradford protein quantification assay has been performed before.For the first time, we have determined an overexpression of chromogranin A in saliva of diabetic patients in 100% of the individuals.Chromogranin A, a circulating biomarker for epithelial tumours, is also overexpressed in saliva of type 2 diabetic patients. To confirm our results, more studies with a large amount of patients is necessary.

  13. Some Biological Activities of Malaysian Leech Saliva Extract

    OpenAIRE

    Abdualrahman M. Abdualkader; Ahmed Merzouk; Abbas Mohammed Ghawi; and Mohammed Alaama

    2011-01-01

    Leeches were fed on the phagostimulatory solution through parafilm membrane. The satiated leeches were forced to regurgitate the solution by soaking them in an ice-container. The anticoagulant activity was ascertained using thrombin time assay (TT). The result revealed that the saliva concentration which increases TT by 100% (IC100) is 43.205µg/ml plasma. The antimicrobial activity of the saliva was tested against several bacterial spp. (E.coli, P.aeruginosa, B.cereus, Sal.typhi and S...

  14. Pengaruh Berkumur Air Kelapa Muda Terhadap Ph Saliva

    OpenAIRE

    Mokoginta, Zuthra P

    2017-01-01

    PENGARUH BERKUMUR AIR KELAPA MUDA TERHADAP pH SALIVA Zuthra P. Mokoginta1) , Vonny N.S. Wowor1) , Juliatri1) 1)Program Studi Pendidikan Dokter Gigi, Fakultas Kedokteran UNSRAT Manado, 95115 ABSTRACT Saliva is one factor that contributes to the development of caries, particularly in the process of demineralization. The low pH in the oral cavity will facilitate the growth of acidogenic bacteria such as Streptococcus mutans and Lactobacillus which is the main cause microorganisms in th...

  15. Electrochemical behavior and pH stability of artificial salivas for corrosion tests.

    Science.gov (United States)

    Queiroz, Gláucia Maria Oliveira de; Silva, Leandro Freitas; Ferreira, José Tarcísio Lima; Gomes, José Antônio da Cunha P; Sathler, Lúcio

    2007-01-01

    It is assumed that the compositions of artificial salivas are similar to that of human saliva. However, the use of solutions with different compositions in in vitro corrosion studies can lead dissimilar electrolytes to exhibit dissimilar corrosivity and electrochemical stability. This study evaluated four artificial salivas as regards pH stability with time, redox potentials and the polarization response of an inert platinum electrode. The tested solutions were: SAGF medium, Mondelli artificial saliva, UFRJ artificial saliva (prepared at the School of Pharmacy, Federal University of Rio de Janeiro, RJ, Brazil) and USP-RP artificial saliva (prepared at the School of Pharmaceutical Sciences of Ribeirão Preto, University of São Paulo, SP, Brazil). It was observed that pH variations were less than 1 unit during a 50-hour test. The SAGF medium, and the UFRJ and USP-RP solutions exhibited more oxidizing characteristics, whereas the Mondelli solution presented reducing properties. Anodic polarization revealed oxidation of the evaluated electrolytes at potentials below +600 mV SCE. It was observed that the UFRJ and USP-RP solutions presented more intense oxidation and reduction processes as compared to the Mondelli and SAGF solutions.

  16. Investigations of serum HPL during pregnancy using two different radioimmunoassays

    International Nuclear Information System (INIS)

    Stracke, H.

    1978-01-01

    The interassay investigations showed that it is absolutely necessary to standardize the HPL antisera as well as the standard sera, as it is otherwise impossible to compare and interpret the findings of different HPL radioimmunoassays. The investigations have shown that in addition to conventional clinical examinations and laboratory test methods (urine estriol determination, DHEAS-dehydroepiandrosterone sulphate test-, urine pregnandiol determination, and determination of heat-resisting alkaline serum phosphatase), HPL concentration determination is a parameter of the nutritive function of the placenta. (orig.) [de

  17. Precision and costs of techniques for self-monitoring of serum glucose levels.

    OpenAIRE

    Chiasson, J. L.; Morrisset, R.; Hamet, P.

    1984-01-01

    The poor correlation between serum and urine glucose measurements has led to the development of new techniques for monitoring the blood glucose level in diabetic patients. Either a nurse or the patient can perform these tests, which involve spreading a single drop of blood onto a reagent strip. A colour change that is proportional to the serum glucose level can be read visually or with a reflectance meter. Evaluated against simultaneous serum glucose levels determined by the hospital biochemi...

  18. Candida in saliva of Brazilian hemophilic patients Candida na saliva de pacientes hemofílicos brasileiros

    Directory of Open Access Journals (Sweden)

    Claudio Maranhão Pereira

    2004-12-01

    Full Text Available Hemophilia is a common hereditary hemorrhagic disorder, however little is known about the oral microflora of hemophilic patients. The aim of this study was to quantify the Candida and identify its species in non-stimulated saliva of hemophilic patients, and consider its relationship with clinical factors influencing Candida carriage. This study comprised evaluation of 86 hemophilic patients of the Hematology Center/UNICAMP and 43 healthy subjects as controls. All patients were submitted to anamnesis, intraoral examination and unstimulated saliva collection. Candida counts and species identification were performed in salivary samples. Candida was present in 64% of the hemophilic patients and in 44% of the healthy controls. C. albicans represented 65% and 68% of the isolated species, in hemophiliacs and control group respectively, and C. tropicalis was the second most common species in both groups. These results indicate that hemophilic patients carry Candida more frequently and in higher counts than healthy controls, independently of oral clinical parameter considered, as viral infections, complete dentures, transfusions of hemoderivatives, and salivary flow.Hemofilia é uma alteração hemorrágica hereditária comum, entretanto pouco se sabe a respeito da microbiota oral destes indivíduos. O objetivo deste estudo foi quantificar a presença de Candida e identificar as suas espécies na saliva de hemofílicos, correlacionando os resultados com fatores clínicos que possam influenciar a presença deste fungo. Foram avaliados 86 hemofílicos do Hemocentro/UNICAMP e 43 indivíduos saudáveis. Todos os pacientes foram submetidos a anamnese, exame clínico intra-oral e coleta de saliva de forma não estimulada. A quantificação e identificação das espécies de Candida foram realizadas nas amostras de saliva. Candida estava presente em 64% dos hemofílicos e em 44% dos indivíduos saudáveis. C. albicans representou 65% e 68% das esp

  19. Preliminary findings on the correlation of saliva pH, buffering ...

    African Journals Online (AJOL)

    The aim of the present comparative study was to compare some salivary characteristics between exclusive waterpipe smokers (EWPS) and non-smokers. 72 males (36 EWPS) were recruited. The volume of stimulated saliva was determined and divided by the duration of saliva collection. The pH was measured directly ...

  20. Effects of different tastants on parotid saliva flow and composition

    NARCIS (Netherlands)

    Neyraud, E.; Heinzerling, C.I.; Bult, J.H.F.; Mesmin, C.; Dransfield, E.

    2009-01-01

    Saliva from parotid glands plays a role in taste perception. Parotid saliva is also stimulated by tastants. The aim of this work is to investigate the effects of different tastants on the parotid salivary response in six subjects. Five tastants were given in different concentrations in solution and

  1. Impaired Urine Dilution Capability in HIV Stable Patients

    Directory of Open Access Journals (Sweden)

    Waldo H. Belloso

    2014-01-01

    Full Text Available Renal disease is a well-recognized complication among patients with HIV infection. Viral infection itself and the use of some antiretroviral drugs contribute to this condition. The thick ascending limb of Henle’s loop (TALH is the tubule segment where free water clearance is generated, determining along with glomerular filtration rate the kidney’s ability to dilute urine. Objective. We analyzed the function of the proximal tubule and TALH in patients with HIV infection receiving or not tenofovir-containing antiretroviral treatment in comparison with healthy seronegative controls, by applying a tubular physiological test, hyposaline infusion test (Chaimowitz’ test. Material & Methods. Chaimowitz’ test was performed on 20 HIV positive volunteers who had normal renal functional parameters. The control group included 10 healthy volunteers. Results. After the test, both HIV groups had a significant reduction of serum sodium and osmolarity compared with the control group. Free water clearance was lower and urine osmolarity was higher in both HIV+ groups. Proximal tubular function was normal in both studied groups. Conclusion. The present study documented that proximal tubule sodium reabsorption was preserved while free water clearance and maximal urine dilution capability were reduced in stable HIV patients treated or not with tenofovir.

  2. Direct Agglutination Test and Enzyme Linked Immunosorbent Assay with Urine Samples for the Diagnosis of Visceral Leishma-niasis

    Directory of Open Access Journals (Sweden)

    Sarkari B

    2007-07-01

    Full Text Available Background: Visceral leishmaniasis (VL or Kala azar is an infectious disease caused by various species of Leishmania parasites. The aim of this study was to detect and compare the presence of anti-Leishmania antibodies in the urine of vis-ceral leishmaniasis patients using ELISA and DAT methods."nMethods: A total of 30 urine samples were collected from VL patients referred to Shiraz (southeast of Iran hospitals. Moreover 31 urine samples were collected from healthy individuals and patients with other diseases such as malaria, brucellosis, hydatidosis and cutaneous leishmaniasis. Collected samples were examined to detect anti-Leishmania antibod-ies in urine, using ELISA and DAT."nResults: Anti-Leishmania antibody was detected in urine of 18 out of 30 (60% VL patients by DAT while ELISA detected anti-Leishmania antibodies in urine of 28 out of 30 (93.3% of VL cases. Sensitivity and specificity of urine-based DAT was 60% and 83.9%, respectively while sensitivity and specificity of urine-based ELISA were 93.3% and 93.5%, corre-spondingly. "nConclusion: Urine-based DAT and ELISA have a reasonable specificity and sensitivity in diagnosis of VL. Accordingly, urine-based ELISA might be a suitable alternative for serum based assays for diagnosis of VL.

  3. INFLUENCE OF SYSTEMIC DISEASES AND REMOVABLE ORTHODONTIC APPLIANCES ON THE QUALITY OF SALIVA IN CHILDHOOD.

    Directory of Open Access Journals (Sweden)

    Maya Rashkova

    2012-03-01

    Full Text Available During the last 10 years numerous investigations using saliva as a diagnostic tool have been carried out. The aim of present study is to evaluate saliva qualities for various general diseases and conditions that influence its qualities. (1 Evaluation of salivary flow and saliva consistency of children. (2 Evaluation of saliva pH and buffer capacity of children. Material and Methods. The investigation was carried out with 126 children (age 6 to 17 selected by their general diseases and conditions influencing the oral risk environment. The children were divided into 4 groups: 30 children with diabetes, 25 children with asthma treated with local corticosteroids, 27 healthy children with orthodontic treatment, 34 children as a control group (healthy children. The saliva of the children was tested with the help of “Saliva Check” of GC company. The instructions of the company producer were followed.Results. Stimulated saliva current is reliably lower for children with asthma treated with local corticosteroids, diabetes and children with orthodontic appliances. Saliva pH is with lower values for children with diabetes and asthma – diseases predisposing to acid oral environment. The decreased saliva buffer capacity for children with diabetes and asthma is an indicator for the difficult regulation of the dynamically changing oral electrolytic balance of those children.Conclusion. The saliva parameters studied can be used as biomarkers of the liquid oral environment with regard to the risks for caries and periodontal diseases in children. General health status influences saliva qualities increasing thus indirectly the caries risk.

  4. Creatine metabolism: detection of creatine and guanidinoacetate in saliva of healthy subjects.

    Science.gov (United States)

    Martínez, Lidia D; Bezard, Miriam; Brunotto, Mabel; Dodelson de Kremer, Raquel

    2016-04-01

    Creatine (Cr) plays an important role in storage and transmission of phosphate-bound energy. Cerebral creatine deficiency syndromes comprise three inherited defects in Cr biosynthesis and transport. The aim of this study was to investigate whether Cr and Guanidinoacetate (GAA) can be detected in saliva of healthy subjects and to establish the relationship between salivary and plasma levels of these molecules. An adapted gas chromatography (GC) method is described for the quantification of Cr and GAA biomarkers in saliva. Reference values were established for GAA and Cr in saliva. These values were age dependent (p= 0.001). No difference between genders was observed. We detected a difference between GAA and Cr concentrations in saliva and in plasma. The GC method for simultaneous determination of GAA and Cr in human saliva is fast, reliable, sensitive, non-invasive and precise to use as a biochemical approach in early detection of cerebral creatine deficiency syndromes. Sociedad Argentina de Investigación Odontológica.

  5. Influence of artificial saliva in biofilm formation of Candida albicans in vitro

    Directory of Open Access Journals (Sweden)

    Michelle Peneluppi Silva

    2012-02-01

    Full Text Available Due to the increase in life expectancy, new treatments have emerged which, although palliative, provide individuals with a better quality of life. Artificial saliva is a solution that contains substances that moisten a dry mouth, thus mimicking the role of saliva in lubricating the oral cavity and controlling the existing normal oral microbiota. This study aimed to assess the influence of commercially available artificial saliva on biofilm formation by Candida albicans. Artificial saliva I consists of carboxymethylcellulose, while artificial saliva II is composed of glucose oxidase, lactoferrin, lysozyme and lactoperoxidase. A control group used sterile distilled water. Microorganisms from the oral cavity were transferred to Sabouraud Dextrose Agar and incubated at 37°C for 24 hours. Colonies of Candida albicans were suspended in a sterile solution of NaCl 0.9%, and standardisation of the suspension to 106 cells/mL was achieved. The acrylic discs, immersed in artificial saliva and sterile distilled water, were placed in a 24-well plate containing 2 mL of Sabouraud Dextrose Broth plus 5% sucrose and 0.1 mL aliquot of the Candida albicans suspension. The plates were incubated at 37°C for 5 days, the discs were washed in 2 mL of 0.9% NaCl and placed into a tube containing 10 mL of 0.9% NaCl. After decimal dilutions, aliquots of 0.1 mL were seeded on Sabouraud Dextrose Agar and incubated at 37°C for 48 hours. Counts were reported as CFU/mL (Log10. A statistically significant reduction of 29.89% (1.45 CFU/mL of Candida albicans was observed in saliva I when compared to saliva II (p = 0.002, considering p≤0.05.

  6. Pengaruh (pH Saliva terhadap Terjadinya Karies Gigi pada Anak Usia Prasekolah

    Directory of Open Access Journals (Sweden)

    Made Ayu Lely

    2017-12-01

    Full Text Available AbstractDental caries is a multifactorial process that occurs through the interaction between teeth and saliva as host, the bacteria in the oral cavity, as well as easily fermented foods. Saliva is one of the factors that have a major influence on the severity of dental caries. The aim of this study was to determine the relationship of salivary pH with dental caries among 564 preschool-age children in DIY Province and Banten Province. The results showed that pH levels of the preschool-age children’saliva are more than 75% basic ranging between 6.8 to 8.0 and the highest levels are in Serang District. Index def-t in Serang District is highest (8.83 and the lowest one is in Yogyakarta City (4.97. The mean number of cavities/ decay more than missing teeth or filling teeth. The study indicates that the acidity of saliva among preschool children in the two provinces is not associated with the occurrence of dental caries.It is more likely due to the habit of drinking sweet milk or eating sticky foods.Key words: thepH of saliva, dental caries,sweet food, sticky foods, preschool childrenageAbstrakKaries gigi merupakan proses multifaktor yang terjadi melalui interaksi antara gigi dan saliva sebagai pejamu, bakteri didalam rongga mulut, serta makanan yang mudah difermentasikan. Saliva merupakan salah satu faktor yang mempunyai pengaruh besar terhadap keparahan karies gigi. Tujuan dari penelitian ini adalah untuk mengetahui pengaruh pH saliva terhadap terjadinya karies gigi pada anak usia prasekolah. Penelitian dilakukan secara potong lintang pada 564 orang anak usia prasekolah di Provinsi Daerah Istimewa Yogyakarta (Provinsi DIY dan Provinsi Banten. Hasil penelitian menunjukkan bahwa derajat keasaman (pH saliva pada anak-anak usia prasekolah lebih dari 75% bersifat basa berkisar antara 6,8-8,0 dan tertinggi di Kabupaten Serang. Indeks def-t tertinggi 8,83 di Kabupaten Serang dan yang terendah 4,97 di Kotamadya Yogyakarta. Rerata jumlah gigi berlubang

  7. Urate-Lowering Agents in Asymptomatic Hyperuricemia: Role of Urine Sediment Analysis and Musculoskeletal Ultrasound.

    Science.gov (United States)

    Viggiano, Davide; Gigliotti, Giuseppe; Vallone, Gianfranco; Giammarino, Anna; Nigro, Michelangelo; Capasso, Giovambattista

    2018-01-01

    Current urate-lowering therapy (ULT) includes three direct acting drugs (allopurinol, febuxostat, Rasburicase) and at least four 'indirect' drugs with other important targets (canagliflozin, losartan, fenofibrate and sevelamer). Moreover, the alcalinization of urines using bicarbonate can be used to dissolve urate crystals and the clinician may discontinue several drugs are known to increase serum levels of uric acid, such as diuretics, aspirin, cyclosporine, theophylline, mycophenolate and ACE inhibitors. While there is a consensus to start ULT in cases of symptomatic hyperuricemia (gout, urate-nephrolithiasis), the very frequent conditions of asymptomatic hyperuricemia remains a major conundrum. The effect of asymptomatic hyperuricemia on kidney function has had fluctuating positions over decades. The conflicting results might indicate: (i) the presence of counterbalancing positive and negative effects on kidney function of both serum uric acid and urate-lowering agents, (ii) the presence of a subpopulation of patients, as yet unidentified, which could truly benefit from a urate-lowering therapy. Therefore, today the treatment of asymptomatic hyperuricemia is not recommended nor excluded by current guidelines. Here we suggest that a possible guide for the treatment of asymptomatic hyperuricemia might be the presence of urate crystals in the urine sediment and/or signs of asymptomatic articular damage by urates, identified by musculo-skeletal ultrasound. Moreover, a watchful analysis of the trend in creatinine/eGFR, proteinuria or urate levels might also guide the clinician. Initiation of ULT and follow-up in cases of asymptomatic hyperuricemia should consider urine sediment analysis, musculoskeletal ultrasound and trends in creatinine, proteinuria and serum urate levels. © 2018 The Author(s). Published by S. Karger AG, Basel.

  8. [The physicochemical and microbiological characteristics of saliva during and after pregnancy].

    Science.gov (United States)

    Martínez-Pabón, María C; Martínez Delgado, Cecilia M; López-Palacio, Ana M; Patiño-Gómez, Lina M; Arango-Pérez, Eduin A

    2014-01-01

    Identify the changes in some physiological and microbiological parameters in the saliva from a group of women during and after their pregnancies. Stimulated whole saliva was collected from a cohort of 35 women during their pregnancy and afterwards to determine each sample's physicochemical (secretion rate, pH and buffer capacity) and microbiological characteristics (acidogenic bacteria count). The pH and buffer capacity of saliva during pregnancy were lower than after pregnancy. There were no statistically significant changes regarding S. mutans and Lactobacillus spp. count, but a tendency towards increased values during pregnancy was noted. Changes occurring in the saliva of pregnant women can lead to an increase of risk of suffering disease affecting one's oral health, such as caries, gingivitis and periodontal disease; this could be prevented by appropriate diagnosis and dental follow-up, including education regarding pregnant women's oral health.

  9. Clinical aspects of Candida species carriage in saliva of xerotomic subjects.

    Science.gov (United States)

    Torres, S R; Peixoto, C B; Caldas, D M; Silva, E B; Magalhães, F A C; Uzeda, M; Nucci, M

    2003-10-01

    In order to investigate the clinical factors that might influence the diversity and the degree of Candida species carriage in saliva, we conducted a cross-sectional study with 133 patients with complaints of xerostomia. Anamnesis, oral examination and collection of chewing-stimulated whole saliva were performed. The samples of saliva were kept refrigerated until they were plated onto CHROMagar Candida; cfu were counted and Candida species were identified by standard methods. There was a high prevalence of mixed Candida colonization. No relationship was found between total Candida cfu counts and variables like gender, age, place of origin, underlying diseases, exposure to medications (except antibiotics), daily habits and salivary flow rates. Oral candidiasis, antibiotic exposure and dental prosthesis wearing were associated with relatively high Candida counts in saliva. Low salivary flow rates predisposed to intense colonization by C. albicans and C. parapsilosis.

  10. Sample Stability and Protein Composition of Saliva: Implications for Its Use as a Diagnostic Fluid

    Directory of Open Access Journals (Sweden)

    Han Roelofsen

    2008-01-01

    Full Text Available Saliva is an easy accessible plasma ultra-filtrate. Therefore, saliva can be an attractive alternative to blood for measurement of diagnostic protein markers. Our aim was to determine stability and protein composition of saliva. Protein stability at room temperature was examined by incubating fresh whole saliva with and without inhibitors of proteases and bacterial metabolism followed by Surface Enhanced Laser Desorption/Ionization (SELDI analyses. Protein composition was determined by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE fractionation of saliva proteins followed by digestion of excised bands and identification by liquid chromatography tandem mass spectrometry (LC-MS/MS. Results show that rapid protein degradation occurs within 30 minutes after sample collection. Degradation starts already during collection. Protease inhibitors partly prevented degradation while inhibition of bacterial metabolism did not affect degradation. Three stable degradation products of 2937 Da, 3370 Da and 4132 Da were discovered which can be used as markers to monitor sample quality. Saliva proteome analyses revealed 218 proteins of which 84 can also be found in blood plasma. Based on a comparison with seven other proteomics studies on whole saliva we identified 83 new saliva proteins. We conclude that saliva is a promising diagnostic fl uid when precautions are taken towards protein breakdown.

  11. Comparative analysis of bacterial profiles in unstimulated and stimulated saliva samples

    DEFF Research Database (Denmark)

    Belstrøm, Daniel; Holmstrup, Palle; Jensen, Allan Bardow

    2016-01-01

    BACKGROUND AND OBJECTIVE: The microbial profiles of stimulated saliva samples have been shown to differentiate between patients with periodontitis, patients with dental caries, and orally healthy individuals. Saliva was stimulated to allow for easy and rapid collection; however, microbial...

  12. Can fluconazole concentrations in saliva be used for therapeutic drug monitoring?

    NARCIS (Netherlands)

    Koks, C. H.; Crommentuyn, K. M.; Hoetelmans, R. M.; Mathôt, R. A.; Beijnen, J. H.

    2001-01-01

    The saliva/plasma concentration ratio of fluconazole was investigated in 22 HIV-1-infected individuals with an oropharyngeal Candida infection to determine whether saliva fluconazole concentrations could provide useful information for therapeutic drug monitoring in this population. Steady-state

  13. The urine marker test

    DEFF Research Database (Denmark)

    Elbe, Anne-Marie; Jensen, Stine Nylandsted; Elsborg, Peter

    2016-01-01

    BACKGROUND: Urine sample collection for doping control tests is a key component of the World Anti-Doping Agency's fight against doping in sport. However, a substantial number of athletes experience difficulty when having to urinate under supervision. Furthermore, it cannot always be ensured...... that athletes are actually delivering their own urine. A method that can be used to alleviate the negative impact of a supervised urination procedure and which can also identify urine as coming from a specific athlete is the urine marker test. Monodisperse low molecular weight polyethylene glycols (PEGs......) are given orally prior to urination. Urine samples can be traced to the donor by analysis of the PEGs previously given. OBJECTIVE: The objective of this study was to investigate the use of the urine marker during urine doping control testing. METHODS: Two studies investigated athletes' acceptance...

  14. Muzzle secretion electrolytes as a possible indicator of sodium status in buffalo (Bubalus bubalis) calves: effects of sodium depletion and aldosterone administration.

    Science.gov (United States)

    Kumar, S; Singh, S P

    1981-01-01

    In two separate experiments, the effects of sodium depletion and aldosterone administration on sodium and potassium concentrations in muzzle secretion, saliva and urine were studied in buffalo calves. Sodium deficiency in the animals was experimentally produced by unilateral parotid saliva deprivation for 18 days. During sodium depletion, the sodium levels in saliva and muzzle secretion gradually fell while the potassium level gradually rose. The concentrations of both of these cations in urine gradually fell during the course of sodium depletion. Aldosterone administration in normal (sodium-replete) animals simulated the effects of sodium depletion as far as cationic changes in saliva were concerned. However, aldosterone did not affect sodium and potassium concentration in the urine and in muzzle secretion in a manner similar to that caused by sodium depletion. Though the hormone decreased urinary sodium without affecting urinary potassium, it did not affect the muzzle sodium or potassium. Results suggest that aldosterone affects the composition of saliva and urine in buffaloes as it does in sheep and other ruminants. Similar changes in composition of muzzle secretion and saliva during sodium depletion indicate that the concentration of sodium in muzzle secretion could possibly be used to evaluate the sodium status of animals.

  15. Application of cloud point preconcentration and flame atomic absorption spectrometry for the determination of cadmium and zinc ions in urine, blood serum and water samples

    Directory of Open Access Journals (Sweden)

    Ardeshir Shokrollahi

    2013-01-01

    Full Text Available A simple, sensitive and selective cloud point extraction procedure is described for the preconcentration and atomic absorption spectrometric determination of Zn2+ and Cd2+ ions in water and biological samples, after complexation with 3,3',3",3'"-tetraindolyl (terephthaloyl dimethane (TTDM in basic medium, using Triton X-114 as nonionic surfactant. Detection limits of 3.0 and 2.0 µg L-1 and quantification limits 10.0 and 7.0 µg L-1were obtained for Zn2+ and Cd2+ ions, respectively. Relative standard deviation was 2.9 and 3.3, and enrichment factors 23.9 and 25.6, for Zn2+ and Cd2+ ions, respectively. The method enabled determination of low levels of Zn2+ and Cd2+ ions in urine, blood serum and water samples.

  16. Bacterial composition in whole saliva from patients with severe hyposalivation

    DEFF Research Database (Denmark)

    Belstrøm, Daniel; Holmstrup, Palle; Fiehn, Nils-Erik

    2016-01-01

    OBJECTIVE: The purpose of this study was to compare the microbiota of stimulated whole saliva samples from patients with severe hyposalivation to samples from individuals with normal whole saliva flow rates. It was hypothesized that the two groups differ with regard to salivary bacterial profiles...... with severe hyposalivation do not differ from those of individuals with normal salivary secretion, when there are virtually no untreated active caries lesions present in the oral cavity. This article is protected by copyright. All rights reserved.......OBJECTIVE: The purpose of this study was to compare the microbiota of stimulated whole saliva samples from patients with severe hyposalivation to samples from individuals with normal whole saliva flow rates. It was hypothesized that the two groups differ with regard to salivary bacterial profiles....... METHODS: This cross-sectional study included 36 participants (24 females and 12 males, mean age 58.5 years) with severe hyposalivation and 36 gender-, age- and geographically-matched participants with normal salivary secretion from the Danish Health Examination Survey (DANHES). The microbiota...

  17. Zinc in human serum. Biochemical and clinical aspects. Zink i humant serum. Biokemiske og kliniske aspekter

    Energy Technology Data Exchange (ETDEWEB)

    Kiilerich, S

    1987-01-01

    The zinc ion is essential for the living organism. Many pathological conditions have been described as a consequence of zinc deficiency. As zinc constitutes less than 0.01 percent of the body weight, it conventionally belongs to the group of trace elements. The method of atomic absorption spectrophotometry is used to measure the concentration of zinc in serum and urine from healthy persons. The assumptions of the method is discussed. The importance of protein binding, diet and the diurnal variation of serum zinc concentration is presented. Serum versus plasma zinc concentration is discussed. Reference serum zinc values from 104 normal subjects are given. Zinc in serum is almost entirely bound to proteins. A preliminary model for the estimation of the distribution of zinc between serum albumin and ..cap alpha../sub 2/-macroglobulin is set up. This estimate has been examined by an ultracentrufugation method. The binding of zinc to a ..cap alpha../sup 2/-macroglobulin in normal persons is appoximately 7 percent, in patients with cirrhosis of the liver of alcoholic origin approximately 6 percent, in patients with insulin dependent diabetes mellitus approximately 5 percent, and in patients with chronic renal failure approximately 2 percent. It is concluded, therefore, that for clinical purposes it is sufficient to use the concentration of total serum zinc corrected for the concentration of serum albumin.

  18. Bond strength of self-etch adhesives after saliva contamination at different application steps.

    Science.gov (United States)

    Cobanoglu, N; Unlu, N; Ozer, F F; Blatz, M B

    2013-01-01

    This study evaluated and compared the effect of saliva contamination and possible decontamination methods on bond strengths of two self-etching adhesive systems (Clearfil SE Bond [CSE], Optibond Solo Plus SE [OSE]). Flat occlusal dentin surfaces were created on 180 extracted human molar teeth. The two bonding systems and corresponding composite resins (Clearfil AP-X, Kerr Point 4) were bonded to the dentin under six surface conditions (n=15/group): group 1 (control): primer/bonding/composite; group 2: saliva/drying/primer/bonding/composite; group 3: primer/saliva/rinsing/drying/primer/bonding/composite; group 4: primer/saliva/rinsing/drying/bonding/composite; group 5: primer/bonding (cured)/saliva/rinsing/drying/primer/bonding/composite; group 6: primer/bonding (cured)/saliva/removing contaminated layer with a bur/rinsing/drying/primer/bonding/composite. Shear bond strength was tested after specimens were stored in distilled water at 37°C for 24 hours. One-way analysis of variance and Tukey post hoc tests were used for statistical analyses. For CSE, groups 2, 3, and 4 and for OSE, groups 6, 2, and 4 showed significantly lower bond strengths than the control group (pcontamination occurred after light polymerization of the bonding agent, repeating the bonding procedure recovered the bonding capacity of both self-etch adhesives. However, saliva contamination before or after primer application negatively affected their bond strength.

  19. Blood Contamination in Saliva: Impact on the Measurement of Salivary Oxidative Stress Markers

    Directory of Open Access Journals (Sweden)

    Natália Kamodyová

    2015-01-01

    Full Text Available Salivary oxidative stress markers represent a promising tool for monitoring of oral diseases. Saliva can often be contaminated by blood, especially in patients with periodontitis. The aim of our study was to examine the impact of blood contamination on the measurement of salivary oxidative stress markers. Saliva samples were collected from 10 healthy volunteers and were artificially contaminated with blood (final concentration 0.001–10%. Next, saliva was collected from 12 gingivitis and 10 control patients before and after dental hygiene treatment. Markers of oxidative stress were measured in all collected saliva samples. Advanced oxidation protein products (AOPP, advanced glycation end products (AGEs, and antioxidant status were changed in 1% blood-contaminated saliva. Salivary AOPP were increased in control and patients after dental treatment (by 45.7% and 34.1%, p<0.01. Salivary AGEs were decreased in patients after microinjury (by 69.3%, p<0.001. Salivary antioxidant status markers were decreased in both control and patients after dental treatment (p<0.05 and p<0.01. One % blood contamination biased concentrations of salivary oxidative stress markers. Saliva samples with 1% blood contamination are visibly discolored and can be excluded from analyses without any specific biochemic detection of blood constituents. Salivary markers of oxidative stress were significantly altered in blood-contaminated saliva in control and patients with gingivitis after dental hygiene treatment.

  20. Electrochemical behavior and pH stability of artificial salivas for corrosion tests Comportamento eletroquímico e estabilidade de pH de salivas artificiais para testes de corrosão

    Directory of Open Access Journals (Sweden)

    Gláucia Maria Oliveira de Queiroz

    2007-09-01

    Full Text Available It is assumed that the compositions of artificial salivas are similar to that of human saliva. However, the use of solutions with different compositions in in vitro corrosion studies can lead dissimilar electrolytes to exhibit dissimilar corrosivity and electrochemical stability. This study evaluated four artificial salivas as regards pH stability with time, redox potentials and the polarization response of an inert platinum electrode. The tested solutions were: SAGF medium, Mondelli artificial saliva, UFRJ artificial saliva (prepared at the School of Pharmacy, Federal University of Rio de Janeiro, RJ, Brazil and USP-RP artificial saliva (prepared at the School of Pharmaceutical Sciences of Ribeirão Preto, University of São Paulo, SP, Brazil. It was observed that pH variations were less than 1 unit during a 50-hour test. The SAGF medium, and the UFRJ and USP-RP solutions exhibited more oxidizing characteristics, whereas the Mondelli solution presented reducing properties. Anodic polarization revealed oxidation of the evaluated electrolytes at potentials below +600 mV SCE. It was observed that the UFRJ and USP-RP solutions presented more intense oxidation and reduction processes as compared to the Mondelli and SAGF solutions.Admite-se que as composições das salivas artificiais são semelhantes àquela da saliva humana. A utilização de soluções de composições distintas em estudos de corrosão in vitro, entretanto, pode fazer com que eletrólitos diferentes exibam diferenças no processo corrosivo e na estabilidade eletroquímica. Este estudo avaliou quatro salivas artificiais em relação a estabilidade do pH em função do tempo, potencial redox e resposta à polarização de um eletrodo de platina inerte. As soluções testadas foram: meio SAGF, saliva artificial Mondelli, saliva artificial UFRJ (preparada pela Faculdade de Farmácia da Universidade Federal do Rio de Janeiro, RJ, Brasil e saliva artificial USP-RP (preparada pela

  1. Xylitol concentrations in artificial saliva after application of different xylitol dental varnishes

    OpenAIRE

    Pereira,Agnes de Fátima Faustino; Silva,Thiago Cruvinel da; Silva,Thelma Lopes da; Caldana,Magali de Lourdes; Bastos,José Roberto Magalhães; Buzalaf,Marília Afonso Rabelo

    2012-01-01

    Objective: The present study analyzed xylitol concentrations in artificial saliva over time after application of varnishes containing 10% and 20% xylitol. Material and Methods: Fifteen bovine enamel specimens (8x4 mm) were randomly allocated to 3 groups (n=5/group), according to the type of varnish used: 10% xylitol, 20% xylitol and no xylitol (control). After varnish application (4 mg), specimens were immersed in vials containing 500 mu L of artificial saliva. Saliva samples were collected i...

  2. KDIGO 2012 Clinical Practice Guideline CKD classification rules out creatinine clearance 24 hour urine collection?

    Science.gov (United States)

    Ognibene, A; Grandi, G; Lorubbio, M; Rapi, S; Salvadori, B; Terreni, A; Veroni, F

    2016-01-01

    The recent guideline for the evaluation and management of Chronic Kidney Disease recommends assessing GFR employing equations based on serum creatinine; despite this, creatinine clearance 24-hour urine collection is used routinely in many settings. In this study we compared the classification assessed from CrCl (creatinine clearance 24h urine collection) and e-GFR calculated with CKD-EPI or MDRD formulas. In this retrospective study we analyze consecutive laboratory data: creatinine clearance 24h urine collection, serum creatinine and demographic data such as sex and age from 15,777 patients >18 years of age collected from 2011 to 2013 in our laboratory at Careggi Hospital. The results were then compared to the estimated GFR calculated with the equations according to the recent treatment guidelines. Consecutive and retrospective laboratory data (creatinine clearance 24h urine collection, serum creatinine and, demographic data such as sex and age) from 15,777 patients >18 years of age seen at Careggi Hospital were collected. Comparison between e-GFR calculated with CKD-EPI or MDRD formulas and GFR according CrCl determinations and bias [95% CI] were 11.34 [-47,4/70.1] and 11.4 [-50.2/73] respectively. The concordance for 18/65 years aged group when compared with e-GFR classification between MDRD vs CKDEPI, MDRD vs CrCl and CKD-EPI vs CrCl were 0.78, 0.34, and 0.41 respectively, while in the 65/110years aged group the concordance Kappas were 0.84, 0.38, and 0.36 respectively. The use of CrCl provides a different classification than the estimation of GFR using a prediction equation. The CrCl is unreliable when it is necessary to identify CKD subjects with decrease of GFR of 5ml/min/1.73m(2)/year. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  3. Urine - abnormal color

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003139.htm Urine - abnormal color To use the sharing features on this page, please enable JavaScript. The usual color of urine is straw-yellow. Abnormally colored urine ...

  4. Frequency of enterococcus faecalis in saliva and root canals with treatment failure

    International Nuclear Information System (INIS)

    Khan, I.; Shan, T.; Manzoor, M.A.

    2015-01-01

    To compare the frequency of E. faecalis in the saliva and root canals of teeth associated with apical periodontitis due to endodontic treatment failure in the same patient. Study Design: Cross-sectional comparative study. Place and Duration of Study: Samples were collected from Operative Dentistry Department, AFID, while laboratory processing was done at AFIP, Rawalpindi. Study duration was one year. Patients and Methods: Fifty patients, both males and females with failed endodontic treatment were selected. Saliva and root canal samples were collected from each patient, inoculated on MacKonkey agar plate and incubated at 35-37 degree C for 48 hrs. E. faecalis colonies were identified by colony morphology, gramstain, catalase, bile asculin test, arabinose fermentation and growth in 6% NaCl nutrient broth. Results: The frequency of E. faecalis in saliva was 34% and in root canal it was 58%. Frequency between the presence of E. faecalis in root canals and saliva was found to be statistically different (p = 0.001). Conclusion: The presence of E. faecalis in root canal was not associated with their presence in saliva. (author)

  5. Frequency of enterococcus faecalis in saliva and root canals with treatment failure

    International Nuclear Information System (INIS)

    Shan, T.; Manzoor, M.A.; Hussain, W.

    2014-01-01

    To compare the frequency of E.faecalis in the saliva and root canals of teeth associated with apical periodontitis due to endodontic treatment failure Study. Design: Cross-sectional comparative. Place and Duration of Study: Samples were collected from Operative Dentistry department, AFID, while laboratory processing was done at AFIP, Rawalpindi. Duration of this study was one year. Patients and Method: Fifty patients, both males and females with failed endodontic treatment were selected. Saliva and root canal samples were collected from each patient, inoculated on MacKonkey agar plate and incubated at 35-370 C for 48 hours. E.faecalis colonies were identified by colony morphology, Gram stain, catalase, bile asculin test, arabinose fermentation and growth in 6% NaCl nutrient broth. Results: The frequency of E.faecalis in saliva was 34% and 58% in root canal samples. Frequency of the presence of E.faecalis in root canals and saliva was found to be statistically different (p=0.000). Conclusion: The presence of E.faecalis in root canal was not associated with their presence in saliva. (author)

  6. Antimicrobial defense systems in saliva

    NARCIS (Netherlands)

    van 't Hof, W.; Veerman, E.C.I.; Nieuw Amerongen, A.V.; Ligtenberg, A.J.M.; Ligtenberg, A.J.M.; Veerman, E.C.I.

    2014-01-01

    The oral cavity is one of the most heavily colonized parts of our body. The warm, nutrient-rich and moist environment promotes the growth of a diverse microflora. One of the factors responsible for the ecological equilibrium in the mouth is saliva, which in several ways affects the colonization and

  7. Effect of endurance training on dental erosion, caries, and saliva.

    Science.gov (United States)

    Frese, C; Frese, F; Kuhlmann, S; Saure, D; Reljic, D; Staehle, H J; Wolff, D

    2015-06-01

    The aim of this investigation was to give insights into the impact of endurance training on oral health, with regard to tooth erosion, caries, and salivary parameters. The study included 35 triathletes and 35 non-exercising controls. The clinical investigation comprised oral examination, assessment of oral status with special regard to caries and erosion, saliva testing during inactivity, and a self-administered questionnaire about eating, drinking, and oral hygiene behavior. In addition, athletes were asked about their training habits and intake of beverages and sports nutrition. For saliva assessment during exercise, a subsample of n = 15 athletes volunteered in an incremental running field test (IRFT). Athletes showed an increased risk for dental erosion (P = 0.001). No differences were observed with regard to caries prevalence and salivary parameters measured during inactivity between athletes and controls. Among athletes, a significant correlation was found between caries prevalence and the cumulative weekly training time (r = 0.347, P = 0.04). In athletes after IRFT and at maximum workload, saliva flow rates decreased (P = 0.001 stimulated; P = 0.01 unstimulated) and saliva pH increased significantly (P = 0.003). Higher risk for dental erosions, exercise-dependent caries risk, and load-dependent changes in saliva parameters point out the need for risk-adapted preventive dental concepts in the field of sports dentistry. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Salivary and serum insulin-like growth factor (IGF-1) assays in anorexic patients.

    Science.gov (United States)

    Paszynska, Elzbieta; Dmitrzak-Weglarz, Monika; Slopien, Agnieszka; Tyszkiewicz-Nwafor, Marta; Rajewski, Andrzej

    2016-12-01

    The purpose of this study was to measure the salivary and serum free IGF-1 concentration of patients with anorexia nervosa (AN) in comparison to an average population. A controlled clinical trial was designed for an age- and gender-matched group of 121 AN patients and 77 healthy individuals. A clinical examination was made and blood and salivary samples were taken during the acute stage of AN (BMI measuring free IGF-1 was used. Anorexic patients had significant reductions in salivary unstimulated flow rate (UFR), pH and free IGF-1 levels in their saliva and serum. Significant correlations between serum IGF-1 and BMI; salivary IGF-1 and UFR and pH were detected. Salivary and serum IGF-1 analyses appear to be a reliable biochemical indicator of malnutrition in AN patients. Measurement of salivary IGF-1 levels would allow new perspectives in monitoring AN in its early stages.

  9. Antialarmin effect of tick saliva during the transmission of Lyme disease

    NARCIS (Netherlands)

    Marchal, Claire; Schramm, Frederic; Kern, Aurélie; Luft, Benjamin J.; Yang, Xiaohua; Schuijt, Tim J.; Hovius, Joppe W.; Jaulhac, Benoît; Boulanger, Nathalie

    2011-01-01

    Tick saliva has potent immunomodulatory properties. In arthropod-borne diseases, this effect is largely used by microorganisms to increase their pathogenicity and to evade host immune responses. We show that in Lyme borreliosis, tick salivary gland extract and a tick saliva protein, Salp15, inhibit

  10. Effect of Oestrogen on Altering the Serum and Urinary Levels of Calcium, Phosphate and Magnesium in Hysterectomised Women Compared to Natural Menopausal South Indian Women: A Case Control Study.

    Science.gov (United States)

    Sonu, Yeldose; Avinash, S S; Sreekantha; Arun Kumar, K; Malathi, M; Shivashankara, A R

    2016-07-01

    Given the paucity of studies conducted to know the effect of suddenness and earlier onset of endocrinological changes associated with hysterectomy, on the serum and urinary levels of calcium, magnesium and phosphate the present study was conducted to compare the levels of calcium, magnesium and phosphate in serum and urine of hysterectomised and natural menopausal south Indian women. This is a cross-sectional observational study. The study included three groups of 30 healthy premenopausal, 30 early surgical menopausal and 30 natural post menopausal women. Women suffering from any endocrine disease were excluded. Analysis was performed in serum and urine sample. The levels of calcium, magnesium and phosphate in serum and calcium/creatinine, magnesium/creatinine and phosphate/creatinine ratio were estimated in urine by spectrophotometric method. Hysterectomised women (serum calcium: 8.7 ± 0.09 mg/dl; urine calcium/creatinine: 0.16 ± 0.02) have significantly low serum calcium (p women (serum magnesium: 2.1 ± 0.03; serum phosphate: 4.4 ± 0.16; urinary calcium/creatinine: 0.17 ± 0.02; urinary magnesium/creatinine: 0.09 ± 0.01) have significantly high serum magnesium (p = 0.016), serum phosphate (p = 0.043) and high urinary calcium/creatinine (p = 0.002), magnesium/creatinine ratio (p = 0.025) compared to healthy pre menopausal women. Post menopausal women (serum calcium: 9.1 ± 0.08) have significantly high serum calcium and phosphate compared to hysterectomised women (serum phosphate: 3.93 ± 0.11). Hysterectomised women have significantly low serum calcium, oestrogen and high urinary calcium/creatinine ratio compared to healthy premenopausal women and low serum calcium and low serum phosphate compared to natural postmenopausal women. Natural postmenopausal women had low serum oestrogen and high serum magnesium, serum phosphate, urinary calcium creatinine ratio and urinary magnesium creatinine ratio compared to healthy premenopausal

  11. The determination of serum and urinary endocan concentrations in patients with bladder cancer.

    Science.gov (United States)

    Laloglu, Esra; Aksoy, Hulya; Aksoy, Yılmaz; Ozkaya, Fatih; Akcay, Fatih

    2016-11-01

    Background Endocan (endothelial cell-specific molecule-1) is a proteoglycan and plays an important role in angiogenesis and inflammation. The aim of this study was to evaluate of serum and urinary concentrations of endothelial cell-specific molecule-1 in bladder cancer. Methods The study included 50 bladder cancer patients, 50 with urinary tract infection and 51 healthy volunteers. Serum and urinary endothelial cell-specific molecule-1 concentrations were measured with enzyme linked immunosorbent assay. Results In bladder cancer group, serum and urinary endothelial cell-specific molecule-1 concentrations were significantly higher than in the healthy subjects ( P = 0.003 and P bladder cancer and urinary tract infection groups in terms of serum and urinary endothelial cell-specific molecule-1 concentrations. Urinary endothelial cell-specific molecule-1 concentrations were higher than those of corresponding serum endothelial cell-specific molecule-1 concentrations ( P bladder cancer and urinary tract infection groups, P = 0.002 for healthy subjects). In bladder cancer group, there was a positive correlation between serum endothelial cell-specific molecule-1 and urinary endothelial cell-specific molecule-1 concentrations ( r = 0.32, P = 0.002). For serum endothelial cell-specific molecule-1, sensitivity and specificity were 50%, and 77%, and for urinary endothelial cell-specific molecule-1, 62%, and 71%, respectively. Conclusion Serum and urinary endothelial cell-specific molecule-1 concentrations increase in bladder cancer. This parameter also increases in serum and urine of cases with urinary tract infection. That urinary endothelial cell-specific molecule-1 values were higher than serum endothelial cell-specific molecule-1 values in all groups may be attributed to direct exfoliation of epithelial cells in bladder to urine.

  12. Black Urine

    Directory of Open Access Journals (Sweden)

    Rahim Vakili

    2016-06-01

    Full Text Available A 2-year-old boy was born at term of healthy, non-consanguineous Iranian parents. His mother attended in the clinic with the history of sometimes discoloration of diapers after passing urine. She noticed that first at the age of one month with intensified in recent months. His Physical examination and growth parameters were normal. His mother denied taking any medication (sorbitol, nitrofurantoin, metronidazole, methocarbamol, sena and methyldopa (5. Qualitative urine examination showed dark black discoloration. By this history, alkaptonuria was the most clinical suspicious. A 24-hour-urine sample was collected and sent for quantitative measurements. The urine sample was highly positive for homogentisic acid and negative for porphyrin metabolites.

  13. Effects of isoflurane anesthesia and pilocarpine on rat parotid saliva flow

    DEFF Research Database (Denmark)

    Knudsen, Jacob Dronninglund; Nauntofte, Birgitte; Josipovic, M

    2011-01-01

    rats was 50% slower than that of the sham-irradiated rats. In conclusion, 1.5% isoflurane was found to be a good compromise between proper anesthesia and isoflurane-induced inhibition of saliva secretion. Pilocarpine induces saliva secretion in a dose-dependent matter, with supra-maximal stimulation...

  14. Kinetics of Anti-Phlebotomus perniciosus Saliva Antibodies in Experimentally Bitten Mice and Rabbits.

    Directory of Open Access Journals (Sweden)

    Inés Martín-Martín

    Full Text Available Sand flies are hematophagous arthropods that act as vectors of Leishmania parasites. When hosts are bitten they develop cellular and humoral responses against sand fly saliva. A positive correlation has been observed between the number of bites and antibody levels indicating that anti-saliva antibody response can be used as marker of exposure to sand flies. Little is known about kinetics of antibodies against Phlebotomus perniciosus salivary gland homogenate (SGH or recombinant salivary proteins (rSP. This work focused on the study of anti-P. perniciosus saliva antibodies in sera of mice and rabbits that were experimentally exposed to the bites of uninfected sand flies.Anti-saliva antibodies were evaluated by ELISA and Western blot. In addition, antibody levels against two P. perniciosus rSP, apyrase rSP01B and D7 related protein rSP04 were determined in mice sera. Anti-saliva antibody levels increased along the immunizations and correlated with the number of sand fly bites. Anti-SGH antibody levels were detected in sera of mice five weeks after exposure, and persisted for at least three months. Anti-apyrase rSP01B antibodies followed similar kinetic responses than anti-SGH antibodies while rSP04 showed a delayed response and exhibited a greater variability among sera of immunized mice. In rabbits, anti-saliva antibodies appeared after the second week of exposure and IgG antibodies persisted at high levels, even 7 months post-exposure.Our results contributed to increase the knowledge on the type of immune response P. perniciosus saliva and individual proteins elicited highlighting the use of rSP01B as an epidemiological marker of exposure. Anti-saliva kinetics in sera of experimentally bitten rabbits were studied for the first time. Results with rabbit model provided useful information for a better understanding of the anti-saliva antibody levels found in wild leporids in the human leishmaniasis focus in the Madrid region, Spain.

  15. Urine Levels of Defensin α1 Reflect Kidney Injury in Leptospirosis Patients

    Directory of Open Access Journals (Sweden)

    Haorile Chagan-Yasutan

    2016-09-01

    Full Text Available Leptospirosis is a zoonotic disease whose severe forms are often accompanied by kidney dysfunction. In the present study, urinary markers were studied for potential prediction of disease severity. Urine samples from 135 patients with or without leptospirosis at San Lazaro Hospital, the Philippines, were analyzed. Urine levels of defensin α1 (uDA1 were compared with those of neutrophil gelatinase-associated lipocalin (uNGAL and N-acetyl-β-d-glucosidase (uNAG. Serum creatinine (Cr was used as a marker of kidney injury. The levels of uDA1/Cr, uNGAL/Cr, and uNAG/Cr were positive in 46%, 90%, and 80% of leptospirosis patients, and 69%, 70%, and 70% of non-leptospirosis patients, respectively. In leptospirosis patients, the correlation of uDA1/Cr, uNGAL/Cr and uNAG/Cr levels with serum Cr were r = 0.3 (p < 0.01, r = 0.29 (p < 0.01, and r = 0.02 (p = 0.81, respectively. uDA1/Cr levels were correlated with uNGAL/Cr levels (r = 0.49, p < 0.01 and uNAG/Cr levels (r = 0.47, p < 0.0001 in leptospirosis patients. These findings suggest that uDA1, uNGAL, and uNAG were elevated in leptospirosis patients and reflected various types of kidney damage. uDA1 and uNGAL can be used to track kidney injury in leptospirosis patients because of their correlation with the serum Cr level.

  16. Bacterial profiles of saliva in relation to diet, lifestyle factors, and socioeconomic status

    Directory of Open Access Journals (Sweden)

    Daniel Belstrøm

    2014-04-01

    Full Text Available Background and objective: The bacterial profile of saliva is composed of bacteria from different oral surfaces. The objective of this study was to determine whether different diet intake, lifestyle, or socioeconomic status is associated with characteristic bacterial saliva profiles. Design: Stimulated saliva samples from 292 participants with low levels of dental caries and periodontitis, enrolled in the Danish Health Examination Survey (DANHES, were analyzed for the presence of approximately 300 bacterial species by means of the Human Oral Microbe Identification Microarray (HOMIM. Using presence and levels (mean HOMIM-value of bacterial probes as endpoints, the influence of diet intake, lifestyle, and socioeconomic status on the bacterial saliva profile was analyzed by Mann–Whitney tests with Benjamini–Hochberg's correction for multiple comparisons and principal component analysis. Results: Targets for 131 different probes were identified in 292 samples, with Streptococcus and Veillonella being the most predominant genera identified. Two bacterial taxa (Streptococcus sobrinus and Eubacterium [11][G-3] brachy were more associated with smokers than non-smokers (adjusted p-value<0.01. Stratification of the group based on extreme ends of the parameters age, gender, alcohol consumption, body mass index (BMI, and diet intake had no statistical influence on the composition of the bacterial profile of saliva. Conversely, differences in socioeconomic status were reflected by the bacterial profiles of saliva. Conclusions: The bacterial profile of saliva seems independent of diet intake, but influenced by smoking and maybe socioeconomic status.

  17. Saliva secretion difference before and after rinsing with baking soda on menopause women

    Directory of Open Access Journals (Sweden)

    Dewi Anggraeni

    2007-03-01

    Full Text Available Menopause women can experience a decrease in saliva secretion (decrease. To understand the clear picture about saliva secretion, the volume, flow rate, pH and viscosity were then measured. The aim of this research was to obtain a picture about the difference of saliva secretion before and after rinsing with baking soda on menopause women. The type of the research used was a laboratory quasi-experiment with comparative descriptive form. The technique used in this research is the survey method, and samples were taken using the multistage cluster random sampling method, and t-student statistical analysis. This research was conducted with the saliva collected with spitting method on 45 menopause women. The results show that the average volume, flow rate, pH and viscosity before rinsing with baking soda was 1.79 ml, 0.18 ml/minute, 7.40 and 0.81 mm2/second. The average volume, flow rate, pH and viscosity after rinsing with baking soda were 2.66 ml; 0.27 ml/minute; 8.67 and 0.78 mm2/second. Statistical analysis t-student on α = 0.05 shows volume changes, flow rate, pH and saliva viscosity before and after rinsing with baking soda was 0.873; 0.086; 1.273 and 0.037 respectively. The conclusion shows a significant difference between saliva secretion before and after rinsing with baking soda, and saliva secretion after rinsing with baking soda on menopause women.

  18. Erosive potential of saliva stimulating tablets with and without fluoride in irradiated head and neck cancer patients

    DEFF Research Database (Denmark)

    Lajer, Christel; Buchwald, Christian; Nauntofte, Birgitte

    2009-01-01

    stimulated saliva without fluoride, and with fluoride. Saliva pH was determined without loss of CO(2) and in combination with inorganic measures used to calculate the degree of saturation of hydroxyapatite (HAp) and fluorapatite (FAp). EP was determined directly in all saliva samples by monitored dissolution......BACKGROUND: Patients irradiated in the head and neck region often suffer from severe dry mouth and use acidic saliva stimulating products, which may cause erosion of teeth. PURPOSE: To determine saliva stimulating effects and erosive potential (EP) of acidic saliva stimulating tablets (Xerodent...

  19. Cigarette smoke-exposed saliva suppresses cellular and humoral immune responses in an animal model

    International Nuclear Information System (INIS)

    Jafarzadeh, A.; Bakhshi, H.; Rezayati, M.T.; Nemati, M.

    2009-01-01

    To evaluate the effects of cigarette smoke (CS)-exposed saliva on cellular and antibody responses in an animal model. The stimulatory and non-stimulatory saliva samples were collected from 10 healthy subjects and were then exposed to CS for 20 or 80 minutes. The CS-exposed saliva samples were administrated intraperitoneally (i.p) to male Balb/c mice. Then the delayed type hypersensitivity (DTH) and antibody responses to sheep red blood cell (SRBC) was assessed. Moreover, the total white blood cells (WBC) counts and the blood lymphocytes counts were determined. The mean of DTH responses of animal groups received 20 minutes or 80 minutes CS-exposed saliva samples was significantly lower than that observed in control group. Moreover, The mean titer of anti-SRBC antibody was significantly lower in animal groups who received 80 minutes CS-exposed stimulatory or non-stimulatory saliva as compared to control group (P<0.04 and P<0.002, respectively). The mean counts of blood lymphocytes in 80 minutes CS exposed-stimulatory saliva group was also significantly lower as compared to control group (P<0.05). These results show that the CS-exposed saliva samples have profound suppressive effects on both cellular and humoral immune response in a mouse animal model (JPMA 59:760; 2009). (author)

  20. Ethyl substituted β-cyclodextrin enhanced fluorimetric method for the determination of trace amounts of oxytetracycline in urine, serum, feed of chook and milk

    International Nuclear Information System (INIS)

    Wang Hongjian; Hou Faju; Jiang Chongqiu

    2005-01-01

    A simple sensitive spectrofluorimetric method was developed for the determination of oxytetracycline (OTC). Ethyl substituted β-cyclodextrin (DE-β-CD) can remarkably enhance the fluorescence intensity of the OTC-Eu 3+ complex at λ=612nm and the enhanced fluorescence intensity of Eu 3+ ion is in proportion to the concentration of OTC. Optimum conditions for the determination of OTC were also investigated. The linear range of this method for the determination of OTC is 8.28x10 -8 -1.73x10 -5 mol/L and the limit of detection is 6.76x10 -9 mol/L, respectively. The developed method is practical and relatively free interference from coexisting substances and can be successfully applied to determination of OTC in samples of urine, serum, feed of chook and milk. The enhancement of the fluorescence at λ em =612nm of Eu 3+ ion is because of the inclusion complex OTC-Eu 3+ -DE-β-CD

  1. Ethyl substituted {beta}-cyclodextrin enhanced fluorimetric method for the determination of trace amounts of oxytetracycline in urine, serum, feed of chook and milk

    Energy Technology Data Exchange (ETDEWEB)

    Hongjian, Wang [Department of Chemistry, Shandong Normal University, Jinan 250014 (China); Faju, Hou [Department of Chemistry, Shandong Normal University, Jinan 250014 (China); Chongqiu, Jiang [Department of Chemistry, Shandong Normal University, Jinan 250014 (China)

    2005-05-15

    A simple sensitive spectrofluorimetric method was developed for the determination of oxytetracycline (OTC). Ethyl substituted {beta}-cyclodextrin (DE-{beta}-CD) can remarkably enhance the fluorescence intensity of the OTC-Eu{sup 3+} complex at {lambda}=612nm and the enhanced fluorescence intensity of Eu{sup 3+} ion is in proportion to the concentration of OTC. Optimum conditions for the determination of OTC were also investigated. The linear range of this method for the determination of OTC is 8.28x10{sup -8}-1.73x10{sup -5}mol/L and the limit of detection is 6.76x10{sup -9}mol/L, respectively. The developed method is practical and relatively free interference from coexisting substances and can be successfully applied to determination of OTC in samples of urine, serum, feed of chook and milk. The enhancement of the fluorescence at {lambda}{sub em}=612nm of Eu{sup 3+} ion is because of the inclusion complex OTC-Eu{sup 3+}-DE-{beta}-CD.

  2. Total Protein of Whole Saliva as a Biomarker of Anaerobic Threshold

    Science.gov (United States)

    Bortolini, Miguel Junior Sordi; De Agostini, Guilherme Gularte; Reis, Ismair Teodoro; Lamounier, Romeu Paulo Martins Silva; Blumberg, Jeffrey B.; Espindola, Foued Salmen

    2009-01-01

    Saliva provides a convenient and noninvasive matrix for assessing specific physiological parameters, including some biomarkers of exercise. We investigated whether the total protein concentration of whole saliva (TPWS) would reflect the anaerobic threshold during an incremental exercise test. After a warm-up period, 13 nonsmoking men performed a…

  3. The effect of saliva composition on texture perception of semi-solids

    NARCIS (Netherlands)

    Engelen, L.; Keybus, P.A.M. van den; Wijk, R.A. de; Veerman, E.C.I.; Amerongen, A.V.N.; Bosman, F.; Prinz, J.F.; Bilt, A. van der

    2007-01-01

    Saliva is expected to be of significance for the perception of food stimuli in the mouth. Mixing the food with saliva, including breakdown and dilution, is considered to be of large importance for semi-solids as these products are masticated without chewing. It is known that there are large

  4. Kontrasepsi Hormonal Meningkatkan Kadar α-Amylase Saliva

    Directory of Open Access Journals (Sweden)

    Juni Handajani

    2014-06-01

    Full Text Available Salivary α-amylase atau α-amylase saliva (SAA adalah salah satu enzim dalam saliva yang berperan penting pada inisiasi digesti karbohidrat dan fungsi interaksi bakteri. Kontrasepsi hormonal sangat populer di Indonesia untuk mencegah kehamilan. Penelitian ini bertujuan untuk mengetahui kadar SAA wanita pemakai kontrasepsi pil dan suntik. Subjek penelitian sebanyak 30 perempuan usia 20-35 tahun. Prosedur penelitian telah mendapat persetujuan dari Komite Etik Fakultas Kedokteran Universitas Gadjah Mada Yogyakarta. Subjek dibagi menjadi 3 kelompok (pemakai kontrasepsi pil, suntik, dan kontrol, masing-masing 10 perempuan. Kriteria subjek antara lain subjek sehat, tidak menggunakan alat ortodontik, protesa atau mahkota, serta menggunakan kontrasepsi hormonal lebih dari 3 bulan. Sampel saliva dikumpulkan pada sore hari (16.00-18.00 WIB selama 1 menit dengan metode tanpa stimulasi. Kadar tingkat SAA diukur menggunakan ELISA kit (Salimetrics LLC dengan Optical Density (OD pada 405 nm. Data dianalisis menggunakan ANOVA (p<0,05. Hasil penelitian menunjukkan kadar SAA tertinggi pada perempuan pemakai kontrasepsi  pil dan ada perbedaan yang signifikan diantara tiga kelompok. Disimpulkan bahwa kontrasepsi hormonal meningkatkan kadar SAA. Hormonal Contraceptive Increased The Level of Salivary Α-Amylase. Salivary α-amylase (SAA is one of the most important enzymes in saliva. This enzyme was mainly involved in the initiation of the digestion of starch in the oral cavity and has significant bacterial interactive function. Hormonal contraceptives are very popular in Indonesia to avoid pregnancy. This study aimed to evaluate the level of SAA in woman who taking pill and by injection contraceptives. Thirty women were in subjects, 20-35 years old, approval ethical clearance from Ethic Committee Medical Faculty of Gadjah Mada University, Yogyakarta Indonesia. Subjects were divided into three groups (taking pill contraceptive, by injection contraceptive and

  5. Hubungan Body Mass Index dengan Laju Aliran Saliva (Studi pada Mahasiswa Fakultas Kedokteran Gigi Universitas Andalas

    Directory of Open Access Journals (Sweden)

    Fildzah Nurul Fajrin

    2015-12-01

    Relationship between Body Mass Index and Saliva Flow Rate (A Study in Faculty of Dentistry, Andalas University. Saliva flow rate is an affecting factor of caries formation. Adequate saliva flow rate can prevent cariess formation process and progression of periodontal disease and oral infection. Nutritional status is known as an influencing factor of saliva flow rate. The parameter of nutritional status is Body Mass Index (BMI. The purpose of this study is to discover the relation between BMI and saliva flow rate in College Students of the Dentistry Faculty Andalas University. This observational study with cross sectional design was conducted to 24 college students of the Dentistry Faculty Andalas University whose ages were 18-25 years old who complied with inclussion and exclussion criteria. BMI was calculated with BMI formula. The saliva flow rate was determined with Sialometry Method of Navazesh 2008 with ”ml/minute” unit. The univariat data analysis was caried out to describe each variable. Normality test Kolmogorov Smirnoff was done to see the normal distribution (p > 0,05. After the distribution was proven to be normal, corelation and regression test was executed to discover the relation between BMI and saliva flow rate. Based on the correlation test result, BMI of college students of the Dentistry Faculty Andalas University is χχ ± SD = 24,6 ± 6,02 kg/m2 and saliva flow rate is χχ ± SD = 0,29 ± 0,1 ml/minute. The relation between BMI and saliva flow rate expresses medium correlation with negative direction ( r = - 0,451. The result of linear regression shows that Saliva Flow Rate = 0,404 - 0,008*(BMI. The coefficient of regression BMI 0.008 shows that increasing 1 unit of BMI will decrease saliva flow rate 0,008 ml/minute. This study concludes that there is correlation between Body Mass Index and saliva flow rate. Obesity group has the lowest saliva flow rate, while the saliva flow rate does not decrease in underweight group.

  6. Non-Coding RNAs in Saliva: Emerging Biomarkers for Molecular Diagnostics

    Directory of Open Access Journals (Sweden)

    Blanca Majem

    2015-04-01

    Full Text Available Saliva is a complex body fluid that comprises secretions from the major and minor salivary glands, which are extensively supplied by blood. Therefore, molecules such as proteins, DNA, RNA, etc., present in plasma could be also present in saliva. Many studies have reported that saliva body fluid can be useful for discriminating several oral diseases, but also systemic diseases including cancer. Most of these studies revealed messenger RNA (mRNA and proteomic biomarker signatures rather than specific non-coding RNA (ncRNA profiles. NcRNAs are emerging as new regulators of diverse biological functions, playing an important role in oncogenesis and tumor progression. Indeed, the small size of these molecules makes them very stable in different body fluids and not as susceptible as mRNAs to degradation by ribonucleases (RNases. Therefore, the development of a non-invasive salivary test, based on ncRNAs profiles, could have a significant applicability to clinical practice, not only by reducing the cost of the health system, but also by benefitting the patient. Here, we summarize the current status and clinical implications of the ncRNAs present in human saliva as a source of biological information.

  7. Serum Fetuin-A Levels Related with Microalbuminuria in Diet-Induced Obese Rats

    Directory of Open Access Journals (Sweden)

    Yanyan Li

    2013-01-01

    Full Text Available The aim of the study was to investigate the association between elevated serum fetuin-A and increased urine albumin excretion in obese rats, and whether increased urine albumin excretion was modified by improving hepatic steatosis and lipid metabolism disorder. Male Wistar rats 4 weeks in age were randomly divided into three groups and fed with normal chow (control group, high-fat chow (obesity group, or high-fat chow plus fenofibrate (fenofibrate group. After 24 weeks, both body weight and visceral fat/body weight ratio in obese rats were higher than in controls. A difference in serology markers and pathology associated with hepatic steatosis was also found among the three groups. Serum fetuin-A and the expression of NF-κB in the liver were increased, while serum adiponectin was decreased in obese rats in comparison to controls (. Urinary albumin/creatinine ratio (ACR was increased in the obesity group compared to controls (. The fenofibrate intervention reduced serum fetuin-A and NF-κB expression in the liver and increased serum adiponectin compared to obese rats and was accompanied by decrease in ACR. A positive correlation was found between ACR and fetuin-A (, , and a negative correlation was found between ACR and adiponectin (, . We conclude that elevated fetuin-A levels are associated with microalbuminuria in obese rats, and abnormal albuminuria is reversible by improving hepatic steatosis.

  8. Erosive potential of saliva stimulating tablets with and without fluoride in irradiated head and neck cancer patients

    International Nuclear Information System (INIS)

    Lajer, Christel; Buchwald, Christian; Nauntofte, Birgitte; Specht, Lena; Bardow, Allan; Jensdottir, Thorbjoerg

    2009-01-01

    Background: Patients irradiated in the head and neck region often suffer from severe dry mouth and use acidic saliva stimulating products, which may cause erosion of teeth. Purpose: To determine saliva stimulating effects and erosive potential (EP) of acidic saliva stimulating tablets (Xerodent TM ) with and without fluoride in irradiated head and neck cancer patients. Materials and method: Nineteen irradiated patients (median age 57 years) sucked Xerodent TM tablets with and without fluoride. Saliva collections were divided into three 10-min sessions in the sequence: unstimulated whole saliva, Xerodent TM stimulated saliva without fluoride, and with fluoride. Saliva pH was determined without loss of CO 2 and in combination with inorganic measures used to calculate the degree of saturation of hydroxyapatite (HAp) and fluorapatite (FAp). EP was determined directly in all saliva samples by monitored dissolution of HAp crystals. Results: Saliva flow rates increased significantly (15-fold) when sucking both tablets (p TM with and without fluoride were evaluated as non-erosive, however, for additional caries protection the fluoride variant is preferable.

  9. DNA extraction from human saliva deposited on skin and its use in forensic identification procedures Extração de DNA de saliva humana depositada sobre a pele e sua aplicabilidade aos processos de identificação forense

    Directory of Open Access Journals (Sweden)

    Evelyn Anzai-Kanto

    2005-09-01

    Full Text Available Saliva is usually deposited in bite marks found in many homicides, assault and other criminal cases. In the present study, saliva obtained from volunteers was deposited on skin and recovered for DNA extraction and typing in order to evaluate its usefulness for practical case investigation and discuss the contribution of forensic dentistry to saliva DNA typing. Twenty saliva samples were colleted from different donors and used as suspects' samples. Five of these samples were randomly selected and deposited (250 µl on arm skin. Saliva was collected from skin using the double swab technique. DNA from saliva and skin-deposited saliva samples was extracted by the phenol-chloroform method. DNA samples were amplified by PCR for DNA typing using a set of 15 STRs. The recovery of DNA from saliva deposited in the skin was 14 to 10 times lower than DNA quantity from saliva samples. DNA typing was demonstrated in 4 of 5 deposited saliva samples, the likelihood ratios estimated for these samples based on data of the Brazilian population were 1:11, 1:500, 1:159.140 and 1:153.700.123. Our results indicate that standardized procedures used for DNA collection and extraction from skin-deposited saliva can be used as a method to recover salivary DNA in criminal cases. However, it is important to observe that DNA recovery in forensic samples can be difficult. This study suggests that the analysis of saliva deposited on skin be incorporated into a criminal investigation since it may have great discriminatory power.A saliva é usualmente depositada em marcas de mordida encontradas em homicídios, agressões e outros crimes. Neste estudo, a saliva obtida de voluntários foi depositada na pele, recuperada para extração e tipagem do DNA, para avaliação de sua utilização e sua contribuição na odontologia legal. Vinte amostras de saliva foram coletadas de diferentes doadores e utilizadas como amostras de suspeitos. Cinco dessas amostras foram sorteadas e

  10. Serum amino acid abnormalities in pediatric patients with chronic ...

    African Journals Online (AJOL)

    Mohamad A. El Sawy

    2011-08-10

    Aug 10, 2011 ... physical examination and sample collection from the patients, ... Details of HD session and drugs were gathered ... the serum, aliquoted, and stored frozen at À20 °C until used ..... clinical problem in dialysis patients, which is multifactorial in origin ... the plasma and urine metabolic profiling of atherosclerosis.

  11. Clinical evaluation of the BioFire FilmArray® BioThreat-E test for the diagnosis of Ebola Virus Disease in Guinea.

    Science.gov (United States)

    Gay-Andrieu, Françoise; Magassouba, N'Fally; Picot, Valentina; Phillips, Cynthia L; Peyrefitte, Christophe N; Dacosta, Brigitte; Doré, Ahmadou; Kourouma, Fode; Ligeon-Ligeonnet, Véronique; Gauby, Corentin; Longuet, Christophe; Scullion, Matt; Faye, Ousmane; Machuron, Jean Louis; Miller, Mark

    2017-07-01

    The recent West Africa Ebola outbreak highlighted the need to provide access to rapid, safe and reliable Ebola Virus Disease diagnostics. The objective of this field study was to assess the clinical performance of the FilmArray ® BioThreat-E test for the detection of Ebola Zaïre virus in whole blood in symptomatic patients suspected of Ebola Virus Disease in Conakry (Guinea) from March to July 2015. The BioThreat-E test was compared to the two RT-PCRs, using serum, implemented at Donka Hospital in the emergency context: an in-house developed quantitative one-step RT-PCR adapted from the Weidmann technique, and the RealStar ® Filovirus RT-PCR Kit 1.0 (Altona-Diagnostics). We also assessed the performance of this assay in noninvasive specimens (urine and saliva) to detect infected patients. Of 135 patients enrolled and eligible for performance assessment on whole blood, the sensitivity was 95.7% [95% CI: 85.5-99.5] and specificity 100% [95% CI: 95.9-100]. Of the 37 symptomatic infected patients able to provide saliva and/or urine samples, 34 of the 35 saliva samples and all 3 of the urine samples were positive with the BioThreat-E test. This study showed that the FilmArray BioThreat-E test performs comparably to conventional molecular tests under field conditions, providing results and interpretation in approximately 1h. Due to its operational characteristics, it can be easily deployed in the field during an epidemic and could also be a useful tool for post-outbreak surveillance. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Assessment of serum HE4 levels throughout the normal menstrual cycle.

    Science.gov (United States)

    Moore, Richard G; Plante, Beth; Hartnett, Erin; Mitchel, Jessica; Raker, Christine A; Vitek, Wendy; Eklund, Elizabeth; Lambert-Messerlian, Geralyn

    2017-07-01

    Human epididymis protein 4 is a serum biomarker to aid in differentiating benign and malignant disease in women with a pelvic mass. Interpretation of human epididymis protein 4 results relies on robust normative data. The purpose of this study was to evaluate whether human epididymis protein 4 levels are variable in women during the normal menstrual cycle. Healthy women, 18-45 years old, with regular menstrual cycles were recruited from community gynecologic practices in Rhode Island. Women consented to enroll and to participate by the donation of blood and urine samples at 5 specific times over the course of each cycle. Levels of reproductive hormones and human epididymis protein 4 were determined. Data were analyzed with the use of linear regression after log transformation. Among 74 enrolled cycles, 53 women had confirmed ovulation during the menstrual cycle and completed all 5 sample collections. Levels of estradiol, progesterone, and luteinizing hormone displayed the expected menstrual cycle patterns. Levels of human epididymis protein 4 in serum were relatively stable across the menstrual cycle, except for a small ovulatory (median, 37.0 pM) increase. Levels of human epididymis protein 4 in urine, after correction for creatinine, displayed the same pattern of secretion observed in serum. Serum human epididymis protein 4 levels are relatively stable across the menstrual cycle of reproductive-aged women and can be determined on any day to evaluate risk of ovarian malignancy. A slight increase is expected at ovulation; but even with this higher human epididymis protein 4 level, results are well within the healthy reference range for women (<120 pM). Levels of human epididymis protein 4 in urine warrant further investigation for use in clinical practice as a simple and convenient sample. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Immune responses induced in rabbits after oral administration of bovine serum albumin in combination with different adjuvants (herb extracts, aluminium hydroxide and platinum nanoparticles

    Directory of Open Access Journals (Sweden)

    G. Bižanov

    2016-12-01

    Full Text Available The aim of the current study was to evaluate the immunostimulatory activity of 10 different herbal extracts from Vitex agnus-castus, Vinca major, Aloe arborescens and the polyherbal product containing extracts from Sambucus nigra, Primula versis, Pinus alba, Gentiana lutea, Cetraria islandica, Eucaliptus globulus, Citrus limon and aluminium hydroxide, as well as platinum nanoparticles. Rabbits were immunized three times orally with bovine serum albumin (BSA in combination with the components mentioned above. BSA-specific IgA antibodies in saliva and IgG antibodies in serum were examined by ELISA. It was found that the rabbits immunized with BSA in combination with either platinum nanoparticles or aluminium hydroxide had higher titres of BSA-specific IgA antibodies in their saliva at day 56 of observation. Likewise, rabbits treated with BSA and Vinca major or Aloe arborescens extracts showed higher levels of BSA-specific IgG antibodies in the serum at the end of observation. These results suggest that some plant extracts, aluminium hydroxide and platinum nanoparticles components could be used as oral adjuvants or as immunomodulators for rabbits.

  14. Identifikasi epitop dari Streptococcus mutans terhadap sekretori Imunoglobulin A saliva (The identification of Streptococcus mutans epitopes to secretory Immunoglobulin A saliva

    Directory of Open Access Journals (Sweden)

    Anita Yuliati

    2005-09-01

    Full Text Available S. mutans is one of the etiology agent of dental caries, these bacteria have a surface protein of about 185 kDa named Ag I/II. The secretory of sIgA saliva to Ag I/II of S.mutans has shown to be able to prevent colonization in human oral cavity. Peptides derived from the 824 to 853 residues of the P region of antigen I/II S. mutans related to the pathogenesis of dental caries. The aim of this study was to identify the overlapping sequence of amino acids (epitope derived from the 624 to 853 residues of P of antigen I/II S. mutans to sIgA saliva on caries and caries-free subject in a observational cross sectional study. The P region of antigen I/II S.mutans was cut into 22 peptides of 9 mer sequences with an overlapping of 8 mer and an offset of 1 mer, synthesized on polyethylene pins and tested for the reactivity with an ELISA indirect method to sIgA saliva on caries and caries-free subject. The results of this study showed that amino acid sequences with TPPVKP (832–837 and TAPTKPTY (838–845 were reactive to sIgA saliva on caries and caries-free subject. The conclusion of this study was that the overlapping common sequence of amino acid (epitopes corresponding to TPPVKP (832–837 and TAPTKPTY (838–845 was identified as caries marker epitopes in human.

  15. Protein buffering in model systems and in whole human saliva.

    Directory of Open Access Journals (Sweden)

    Andreas Lamanda

    Full Text Available The aim of this study was to quantify the buffer attributes (value, power, range and optimum of two model systems for whole human resting saliva, the purified proteins from whole human resting saliva and single proteins. Two model systems, the first containing amyloglucosidase and lysozyme, and the second containing amyloglucosidase and alpha-amylase, were shown to provide, in combination with hydrogencarbonate and di-hydrogenphosphate, almost identical buffer attributes as whole human resting saliva. It was further demonstrated that changes in the protein concentration as small as 0.1% may change the buffer value of a buffer solution up to 15 times. Additionally, it was shown that there was a protein concentration change in the same range (0.16% between saliva samples collected at the time periods of 13:00 and others collected at 9:00 am and 17:00. The mode of the protein expression changed between these samples corresponded to the change in basic buffer power and the change of the buffer value at pH 6.7. Finally, SDS Page and Ruthenium II tris (bathophenantroline disulfonate staining unveiled a constant protein expression in all samples except for one 50 kDa protein band. As the change in the expression pattern of that 50 kDa protein band corresponded to the change in basic buffer power and the buffer value at pH 6.7, it was reasonable to conclude that this 50 kDa protein band may contain the protein(s belonging to the protein buffer system of human saliva.

  16. Barium determination in gastric contents, blood and urine by inductively coupled plasma mass spectrometry in the case of oral barium chloride poisoning.

    Science.gov (United States)

    Łukasik-Głębocka, Magdalena; Sommerfeld, Karina; Hanć, Anetta; Grzegorowski, Adam; Barałkiewicz, Danuta; Gaca, Michał; Zielińska-Psuja, Barbara

    2014-01-01

    A serious case of barium intoxication from suicidal ingestion is reported. Oral barium chloride poisoning with hypokalemia, neuromuscular and cardiac toxicity, treated with intravenous potassium supplementation and hemodialysis, was confirmed by the determination of barium concentrations in gastric contents, blood, serum and urine using the inductively coupled plasma mass spectrometry method. Barium concentrations in the analyzed specimens were 20.45 µg/L in serum, 150 µg/L in blood, 10,500 µg/L in urine and 63,500 µg/L in gastric contents. Results were compared with barium levels obtained from a non-intoxicated person. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Xylitol concentrations in artificial saliva after application of different xylitol dental varnishes

    Science.gov (United States)

    PEREIRA, Agnes de Fátima Faustino; da SILVA, Thiago Cruvinel; da SILVA, Thelma Lopes; CALDANA, Magali de Lourdes; BASTOS, José Roberto Magalhães; BUZALAF, Marília Afonso Rabelo

    2012-01-01

    Objective The present study analyzed xylitol concentrations in artificial saliva over time after application of varnishes containing 10% and 20% xylitol. Material and Methods Fifteen bovine enamel specimens (8x4 mm) were randomly allocated to 3 groups (n=5/group), according to the type of varnish used: 10% xylitol, 20% xylitol and no xylitol (control). After varnish application (4 mg), specimens were immersed in vials containing 500 µL of artificial saliva. Saliva samples were collected in different times (1, 8, 12, 16, 24, 48 and 72 h) and xylitol concentrations were analyzed. Data were assessed by two-way repeated-measures ANOVA (pxylitol in saliva samples of the control group. Salivary xylitol concentrations were significantly higher up to 8 h after application of the 20% xylitol varnish. Thereafter, the 10% xylitol varnish released larger amounts of that polyol in artificial saliva. Conclusions Despite the results in short-term, sustained xylitol releases could be obtained when the 10% xylitol varnish was used. These varnishes seem to be viable alternatives to increase salivary xylitol levels, and therefore, should be clinically tested to confirm their effectiveness. PMID:22666828

  18. Morphology and Differentiation of MG63 Osteoblast Cells on Saliva Contaminated Implant Surfaces

    Directory of Open Access Journals (Sweden)

    Neda Shams

    2015-11-01

    Full Text Available Objectives: Osteoblasts are the most important cells in the osseointegration process. Despite years of study on dental Implants, limited studies have discussed the effect of saliva on the adhesion process of osteoblasts to implant surfaces. The aim of this in vitro study was to evaluate the effect of saliva on morphology and differentiation of osteoblasts attached to implant surfaces.Materials and Methods: Twelve Axiom dental implants were divided into two groups. Implants of the case group were placed in containers, containing saliva, for 40 minutes. Then, all the implants were separately stored in a medium containing MG63 human osteoblasts for a week. Cell morphology and differentiation were assessed using a scanning electron microscope and their alkaline phosphatase (ALP activity was determined. The t-test was used to compare the two groups.Results: Scanning electron microscopic observation of osteoblasts revealed round or square cells with fewer and shorter cellular processes in saliva contaminated samples, whereas elongated, fusiform and well-defined cell processes were seen in the control group. ALP level was significantly lower in case compared to control group (P<0.05.Conclusion: Saliva contamination alters osteoblast morphology and differentiation and may subsequently interfere with successful osseointegration. Thus, saliva contamination of bone and implant must be prevented or minimized.

  19. La saliva como medio de diagnóstico de VIH

    Directory of Open Access Journals (Sweden)

    Ricardo Medina Madrid

    2000-12-01

    Full Text Available La saliva como medio diagnóstico permite reconocer las concentraciones de una serie de componentes tanto endógenos como exógenos presentes en el organismo. Gracias a los anticuerpos presentes en la saliva se pueden aplicar las nuevas tecnologías biomédicas en el diagnóstico del síndrome de inmunodeficiencia humana causado por el VIH. Este novedoso método posee numerosas ventajas con respecto a las pruebas en sangre. Se plantea información sobre los fluidos bucales, los diversos componentes con posibilidad de diagnóstico presentes en la saliva y se establecen las características de un método diagnóstico (Omni-Sal® aplicado a personas que padecen de alguna enfermedad del complejo bucal. Descriptores

  20. [Activity of alpha-amylase and concentration of protein in saliva of pregnant women].

    Science.gov (United States)

    Ciejak, Magdalena; Olszewska, Maria; Jakubowska, Katarzyna; Zebiełowicz, Dariusz; Safranow, Krzysztof; Chlubek, Dariusz

    2007-01-01

    One of the hypothetical reasons of the increased incidence of caries in women during the pregnancy may be the increased activity of alpha-amylase, which can be found in their saliva. The enzyme takes part in the process of decomposition of simple sugars, which make basic substrate for caries-causing bacteria. The aim of the paper was the evaluation of the influence of pregnancy and gestational age on the activity of alpha-amylase and the concentration of protein in women's saliva. The examined group consisted of 64 pregnant women at age 17-39, between 21st and 40th week of pregnancy. The control group consisted of 44 healthy women at age 20-35, who were not pregnant. In saliva, which was taken before morning meal, without stimulation, protein concentration was determined by Bradford method and the activity of amylase was determined by kinetic method. The activity of amylase correlated strongly and positively with protein concentration in saliva of both the pregnant (RS = +0.65; p women. There were no significant differences between examined parameters in the examined and the control group. It has been observed in the examined group, that there is the significant negative correlation between protein concentration in saliva and the week of pregnancy (RS = -0.35; p increased caries incidence of pregnant women. However, the observed changes of total protein concentration in saliva during pregnancy, suggest that the exact cognition of proteins in pregnant women's saliva may reveal new mechanisms, which lead to an increase of caries risk.

  1. Acupuncture for serum uric acid in patients with asymptomatic hyperuricemia: A randomized, double-blind, placebo-controlled trial.

    Science.gov (United States)

    Huang, Yingjuan; Meng, Jun; Sun, Baoguo; Xiang, Ting; Zhou, Xin; Xu, Biyu; Wu, Yingzi; Chen, Zexiong; Zhang, Shijun

    2017-04-01

    Hyperuricemia (HUA) is the most common disease associated with cardiovascular disease, metabolic syndrome, hypertension, and kidney disease. The objective of the current study was to evaluate the preliminary efficacy, mechanism, and safety of acupuncture on serum uric acid in patients with asymptomatic HUA. A randomized, placebo-controlled trial among 123 patients with asymptomatic HUA was conducted. The acupoints used in the acupuncture group were bilateral Five Shu in Spleen Meridian. Each participant received the intervention once daily for 10 consecutive days. The sham group received the same treatment duration on the same acupoints by the Park Sham Device. All patients underwent measurements of serum or urine creatinine, uric acid, serum lipid profiles, fasting plasma glucose, HbA1c, xanthine oxidase (XOD) and urate-anion exchanger (URAT-1). At the end of the intervention, the individuals in the acupuncture group were found to have significantly less levels of serum uric acid than those in the sham group [(453±65 vs. 528±81) μmol/L, puric acid level, urine pH value and 24-hour urine volume than the sham treatment (puric acid in a Chinese HUA patient population. The mechanism might be associated with the decrease level of enzyme URAT-1. ChiCTR-TRC-13004122. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Controversies in using urine samples for prostate cancer detection: PSA and PCA3 expression analysis

    Directory of Open Access Journals (Sweden)

    S. Fontenete

    2011-12-01

    Full Text Available PURPOSE: Prostate cancer (PCa is one of the most commonly diagnosed malignancies in the world. Although PSA utilization as a serum marker has improved prostate cancer detection it still presents some limitations, mainly regarding its specificity. The expression of this marker, along with the detection of PCA3 mRNA in urine samples, has been suggested as a new approach for PCa detection. The goal of this work was to evaluate the efficacy of the urinary detection of PCA3 mRNA and PSA mRNA without performing the somewhat embarrassing prostate massage. It was also intended to optimize and implement a methodological protocol for this kind of sampling. MATERIALS AND METHODS: Urine samples from 57 patients with suspected prostate disease were collected, without undergoing prostate massage. Increased serum PSA levels were confirmed by medical records review. RNA was extracted by different methods and a preamplification step was included in order to improve gene detection by Real-Time PCR. RESULTS: An increase in RNA concentration with the use of TriPure Isolation Reagent. Despite this optimization, only 15.8% of the cases showed expression of PSA mRNA and only 3.8% of prostate cancer patients presented detectable levels of PCA3 mRNA. The use of a preamplification step revealed no improvement in the results obtained. CONCLUSION: This work confirms that prostate massage is important before urine collection for gene expression analysis. Since PSA and PCA3 are prostate specific, it is necessary to promote the passage of cells from prostate to urinary tract, in order to detect these genetic markers in urine samples.

  3. Tongue-mandible coupling movements during saliva swallowing.

    Science.gov (United States)

    Bourdiol, P; Mishellany-Dutour, A; Peyron, M-A; Woda, A

    2014-03-01

    The purpose of this study was to measure the tongue and mandible positions and displacements in relation to the maxilla in the midsagittal plane to characterize the different saliva swallowing patterns by recording their kinematics. A 2D electromagnetic articulograph using four transducer coils, three attached to the upper surface of the tongue midline plus one attached to the chin anterior part allowed continuous evaluation of tongue and chin movements in twelve young adults in good general health. During 170 s sequences recorded at a frequency of 100 Hz, subjects were at rest, silently reading a text they had chosen. The subjects were free to swallow during the sequence. Deglutition of accumulated saliva was analysed after averaging all values obtained during successive 250 ms periods. We identified three elementary swallowing patterns. Mean duration of tongue-mandible movements were 1·51 ± 0·17 s, 1·63 ± 0·14 s and 2·00 ± 0·08 s for the first, second and third patterns respectively. In the light of other studies based on intra-oral pressure recordings, our results help to understand the tongue-mandible coupling behaviours involved in managing an in-mouth saliva bolus during the three elementary swallowing patterns identified. © 2014 John Wiley & Sons Ltd.

  4. Characterization of the Activity and Stability of Amylase from Saliva and Detergent: Laboratory Practicals for Studying the Activity and Stability of Amylase from Saliva and Various Commercial Detergents

    Science.gov (United States)

    Valls, Cristina; Rojas, Cristina; Pujadas, Gerard; Garcia-Vallve, Santi; Mulero, Miquel

    2012-01-01

    This article presents two integrated laboratory exercises intended to show students the role of [alpha]-amylases (AAMYs) in saliva and detergents. These laboratory practicals are based on the determination of the enzymatic activity of amylase from saliva and different detergents using the Phadebas test (quantitative) and the Lugol test…

  5. Serum lithium as a compliance marker for food and supplement intake

    NARCIS (Netherlands)

    Roos, de N.; Vries, de J.H.M.; Katan, M.B.

    2001-01-01

    Analyzing 24-h urine for lithium after consumption of lithium-tagged foods or supplements provides a validated compliance marker but is laborious. Objective: Most studies involve blood sampling; therefore, we tested whether serum lithium concentration could be used as a compliance marker. Design: We

  6. Continuous analysis of parotid saliva during resting and short-duration simulated chewing

    NARCIS (Netherlands)

    Neyraud, E.; Bult, J.H.F.; Dransfield, E.

    2009-01-01

    Objective: Parotid saliva flow is increased by mastication and its composition is also modified. The aim of this work was to clarify the relationships between flow rate, pH and protein concentration, during resting and short-duration simulated chewing, using continuous and fractional saliva

  7. Leaching of 210Po in human saliva from smokeless tobacco

    International Nuclear Information System (INIS)

    Syed, U.F.; Bari, A.; Husain, L.; Husain, L.

    2009-01-01

    Use of smokeless tobacco (SLT) is associated with cancer of the oral cavity. 210 Po, a known carcinogen present in SLT may leach into the saliva when the snuff is held in the mouth. Alpha emission from leached 210 Po can cause oral tissue damage, especially in the presence of non healing ulcers seen frequently in snuff users' mouth. Leaching of 210 Po from SLT in human saliva was determined for six popular US snuff brands. 210 Po was leached into human saliva for 30 min, separated radiochemically and its activity was determined by α-counting. Approximately 2-10% of 210 Po present in SLT was observed to leach. Annual exposure from leached 210 Po, based on average daily consumption of 15 g of SLT, was calculated to range from 1.1 to 3.8 Bq year -1 . (author)

  8. Trefoil factors in saliva and gingival tissues of patients with chronic periodontitis

    DEFF Research Database (Denmark)

    Chaiyarit, Ponlatham; Chayasadom, Anek; Wara-Aswapati, Nawarat

    2012-01-01

    BACKGROUND: Trefoil factors (TFFs) are secreted molecules that are involved in cytoprotection against tissue damage and the immune response. TFFs have been detected in saliva and oral tissues, but their clinical significance has never been investigated in patients with chronic periodontitis....... The objective of this study is to determine whether TFF expression in saliva and gingival tissues is associated with periodontal pathology. METHODS: Saliva and gingival tissue samples were collected from 25 non-periodontitis individuals and 25 patients with chronic periodontitis (CP). Enzyme...... observed in patients with CP (P = 0.003 and P periodontal pathology and number of Porphyromonas gingivalis...

  9. Effect of blood contamination on results of dipstick evaluation and urine protein-to-urine creatinine ratio for urine samples from dogs and cats.

    Science.gov (United States)

    Vientós-Plotts, Aida I; Behrend, Ellen N; Welles, Elizabeth G; Chew, Dennis J; Gaillard, Philippe R; Busler, Jessica N; Lee, Hollie P

    2018-05-01

    OBJECTIVE To evaluate effects of blood contamination on dipstick results, specific gravity (SG), and urine protein-to-urine creatinine ratio (UPCR) for urine samples from dogs and cats. SAMPLE Urine samples collected from 279 dogs and 120 cats. PROCEDURES Urine pools were made for each species (dogs [n = 60] and cats [30]). Blood was added to an aliquot of a pool, and serial dilutions were prepared with the remaining urine. Color and dipstick variables were recorded, and SG and UPCR were measured. For cats, 1 set of pools was used; for dogs, 2 sets were used. Comparisons were made between undiluted urine and spiked urine samples for individual colors. Repeated-measures ANOVA on ranks was used to compare dipstick scores and UPCR results; χ 2 tests were used to compare proteinuria categorizations (nonproteinuric, borderline, or proteinuric). RESULTS Any blood in the urine resulted in significantly increased dipstick scores for blood. In both species, scores for bilirubin and ketones, pH, and SG were affected by visible blood contamination. No significant difference for the dipstick protein reagent results was evident until a sample was visibly hematuric. The UPCR was significantly increased in dark yellow samples of both species. Proteinuria categorizations differed significantly between undiluted urine and urine of all colors, except light yellow. CONCLUSIONS AND CLINICAL RELEVANCE Any degree of blood contamination affected results of dipstick analysis. Effects depended on urine color and the variable measured. Microscopic blood contamination may affect the UPCR; thus, blood contamination may be a differential diagnosis for proteinuria in yellow urine samples.

  10. Novel Two-Component System of Streptococcus sanguinis Affecting Functions Associated with Viability in Saliva and Biofilm Formation.

    Science.gov (United States)

    Camargo, Tarsila M; Stipp, Rafael N; Alves, Lívia A; Harth-Chu, Erika N; Höfling, José F; Mattos-Graner, Renata O

    2018-04-01

    Streptococcus sanguinis is a pioneer species of teeth and a common opportunistic pathogen of infective endocarditis. In this study, we identified a two-component system, S. sanguinis SptRS (SptRS Ss ), affecting S. sanguinis survival in saliva and biofilm formation. Isogenic mutants of sptR Ss (SKsptR) and sptS Ss (SKsptS) showed reduced cell counts in ex vivo assays of viability in saliva compared to those of parent strain SK36 and complemented mutants. Reduced counts of the mutants in saliva were associated with reduced growth rates in nutrient-poor medium (RPMI) and increased susceptibility to the deposition of C3b and the membrane attach complex (MAC) of the complement system, a defense component of saliva and serum. Conversely, sptR Ss and sptS Ss mutants showed increased biofilm formation associated with higher levels of production of H 2 O 2 and extracellular DNA. Reverse transcription-quantitative PCR (RT-qPCR) comparisons of strains indicated a global role of SptRS Ss in repressing genes for H 2 O 2 production (2.5- to 15-fold upregulation of spxB , spxR , vicR , tpk , and ackA in sptR Ss and sptS Ss mutants), biofilm formation, and/or evasion of host immunity (2.1- to 11.4-fold upregulation of srtA , pcsB , cwdP , iga , and nt5e ). Compatible with the homology of SptR Ss with AraC-type regulators, duplicate to multiple conserved repeats were identified in 1,000-bp regulatory regions of downstream genes, suggesting that SptR Ss regulates transcription by DNA looping. Significant transcriptional changes in the regulatory genes vicR , spxR , comE , comX , and mecA in the sptR Ss and sptS Ss mutants further indicated that SptRS Ss is part of a regulatory network that coordinates cell wall homeostasis, H 2 O 2 production, and competence. This study reveals that SptRS Ss is involved in the regulation of crucial functions for S. sanguinis persistence in the oral cavity. Copyright © 2018 American Society for Microbiology.

  11. Rapid simultaneous determination of organophosphorus pesticides in human serum and urine by liquid chromatography-mass spectrometry

    Directory of Open Access Journals (Sweden)

    Zlatković Milica

    2010-01-01

    Full Text Available Background/Aim. Analysis of organophosphosphorus compounds and their metabolites in a biological material includes the use of numerous methods, covering both preparation of samples for analysis and their identification that is considered to be very complex. Low concentrations monitoring requires implementation of highly sensitive analytical techniques. The aim of this study was to develop and validate an original and sensitive method for the detection and quantitation of organophosphorus pesticides (dimethoate, diazinon, malathion and malaoxon in human biological matrices (serum, urine. Methods. This method was based on a solid-phase extraction procedure, a chromatographic separation using an ACQUITY UPLC ® HSST3 column and mass spectrometric detection in the positve ion mode. Mobile phase: was consited of Solvent A (5 mM ammonium formate pH 3.0 and Solvent B (0.1% acetic formate in methanol, in a linear gradient (constant flow-rate 0.3 mL/min. Results. The standard curve was linear in the range of 0.05-5.00 mg/L for malathion and malaoxon, 0.10-5.00 mg/L for dimethoate and 0.05-2.50 mg/L for diazinon. The correlation coefficient was r ≥ 0.99. Extraction recoveries were satisfactory and ranged between 90-99%. The limits of detection (LOD was between 0.007- 0.07 mg/L and the limits of quantitation (LOQ ranged between 0.022-0.085 mg/L. Intra- and interassay precision and accuracy were satisfactory for all of the pesticides analyzed. Conclusion. The method of liquid chromatography - mass spectrometry is simple, accurate, and useful for the determination of organophosphorus pesticides in both clinical and forensic toxicology.

  12. Urine culture - catheterized specimen

    Science.gov (United States)

    Culture - urine - catheterized specimen; Urine culture - catheterization; Catheterized urine specimen culture ... urinary tract infections may be found in the culture. This is called a contaminant. You may not ...

  13. Whole Saliva has a Dual Role on the Adherence of Candida albicans to Polymethylmetacrylate.

    Science.gov (United States)

    Elguezabal, N; Maza, J L; Dorronsoro, S; Pontón, J

    2008-01-01

    Adhesion of Candida albicans to acrylic of dental prostheses or to salivary macromolecules adsorbed on their surface is believed to be a critical event in the development of denture stomatitis. In previous studies our group has shown that adhesion of C. albicans germ tubes to polystyrene is decreased by saliva whereas C. albicans yeast cells adhesion to the same material is enhanced. The results presented in this study confirm this dual role played by whole saliva, since it decreased the adhesion of germ tubes but increased the adhesion of yeast cells to polymethylmetacrylate (PMMA). These effects mediated by whole saliva do not seem to be related to an inhibition of the germination of C. albicans, since similar levels of filamentation were observed in presence and absence of saliva. These results may give new insights into the conflicting role of saliva in the adhesion of C. albicans to acrylic resins of dental prostheses.

  14. The Urine Marker Test: An Alternative Approach to Supervised Urine Collection for Doping Control.

    Science.gov (United States)

    Elbe, Anne-Marie; Jensen, Stine Nylansted; Elsborg, Peter; Wetzke, Monika; Woldemariam, Getachew A; Huppertz, Bernd; Keller, Ruprecht; Butch, Anthony W

    2016-01-01

    Urine sample collection for doping control tests is a key component of the World Anti-Doping Agency's fight against doping in sport. However, a substantial number of athletes experience difficulty when having to urinate under supervision. Furthermore, it cannot always be ensured that athletes are actually delivering their own urine. A method that can be used to alleviate the negative impact of a supervised urination procedure and which can also identify urine as coming from a specific athlete is the urine marker test. Monodisperse low molecular weight polyethylene glycols (PEGs) are given orally prior to urination. Urine samples can be traced to the donor by analysis of the PEGs previously given. The objective of this study was to investigate the use of the urine marker during urine doping control testing. Two studies investigated athletes' acceptance of this new method via two questionnaires (n = 253). Furthermore, a third study (n = 91) investigated whether ingestion of the marker can identify the urine as coming from a specific person and whether the marker interferes with the detection of prohibited substances. The results indicate that this new method finds wide acceptance both from athletes who have only heard about the procedure and those who have actually tested the new method. Furthermore, the marker, which can identify urine as coming from a specific person, does not interfere with the detection of prohibited substances.

  15. Urine Odor

    Science.gov (United States)

    ... doctor. Brunzel NA. Physical examination of urine. In: Fundamentals of Urine and Body Fluid Analysis. 3rd ed. St. Louis, Mo.: Saunders Elsevier; 2013:97. McPherson RA, et al., eds. Henry's Clinical Diagnosis and Management by Laboratory Methods. 23rd ed. St. Louis, Mo.: ...

  16. Effect of low-dose ketamine on post-operative serum IL-6 production ...

    African Journals Online (AJOL)

    Department of Anaesthesia Mulago National Referral Hospital's ... Materials and methods: Institutional Review Board's approval was sought and RCT was ... Blood samples were collected and laboratory analyzed at baseline, ... The greater the surgical trauma, the greater the serum ..... Plasma, urine, and cerebrospinal fluid.

  17. The Human Serum Metabolome

    Science.gov (United States)

    Psychogios, Nikolaos; Hau, David D.; Peng, Jun; Guo, An Chi; Mandal, Rupasri; Bouatra, Souhaila; Sinelnikov, Igor; Krishnamurthy, Ramanarayan; Eisner, Roman; Gautam, Bijaya; Young, Nelson; Xia, Jianguo; Knox, Craig; Dong, Edison; Huang, Paul; Hollander, Zsuzsanna; Pedersen, Theresa L.; Smith, Steven R.; Bamforth, Fiona; Greiner, Russ; McManus, Bruce; Newman, John W.; Goodfriend, Theodore; Wishart, David S.

    2011-01-01

    Continuing improvements in analytical technology along with an increased interest in performing comprehensive, quantitative metabolic profiling, is leading to increased interest pressures within the metabolomics community to develop centralized metabolite reference resources for certain clinically important biofluids, such as cerebrospinal fluid, urine and blood. As part of an ongoing effort to systematically characterize the human metabolome through the Human Metabolome Project, we have undertaken the task of characterizing the human serum metabolome. In doing so, we have combined targeted and non-targeted NMR, GC-MS and LC-MS methods with computer-aided literature mining to identify and quantify a comprehensive, if not absolutely complete, set of metabolites commonly detected and quantified (with today's technology) in the human serum metabolome. Our use of multiple metabolomics platforms and technologies allowed us to substantially enhance the level of metabolome coverage while critically assessing the relative strengths and weaknesses of these platforms or technologies. Tables containing the complete set of 4229 confirmed and highly probable human serum compounds, their concentrations, related literature references and links to their known disease associations are freely available at http://www.serummetabolome.ca. PMID:21359215

  18. Comparative analysis of detection methods for congenital cytomegalovirus infection in a Guinea pig model.

    Science.gov (United States)

    Park, Albert H; Mann, David; Error, Marc E; Miller, Matthew; Firpo, Matthew A; Wang, Yong; Alder, Stephen C; Schleiss, Mark R

    2013-01-01

    To assess the validity of the guinea pig as a model for congenital cytomegalovirus (CMV) infection by comparing the effectiveness of detecting the virus by real-time polymerase chain reaction (PCR) in blood, urine, and saliva. Case-control study. Academic research. Eleven pregnant Hartley guinea pigs. Blood, urine, and saliva samples were collected from guinea pig pups delivered from pregnant dams inoculated with guinea pig CMV. These samples were then evaluated for the presence of guinea pig CMV by real-time PCR assuming 100% transmission. Thirty-one pups delivered from 9 inoculated pregnant dams and 8 uninfected control pups underwent testing for guinea pig CMV and for auditory brainstem response hearing loss. Repeated-measures analysis of variance demonstrated no statistically significantly lower weight for the infected pups compared with the noninfected control pups. Six infected pups demonstrated auditory brainstem response hearing loss. The sensitivity and specificity of the real-time PCR assay on saliva samples were 74.2% and 100.0%, respectively. The sensitivity of the real-time PCR on blood and urine samples was significantly lower than that on saliva samples. Real-time PCR assays of blood, urine, and saliva revealed that saliva samples show high sensitivity and specificity for detecting congenital CMV infection in guinea pigs. This finding is consistent with recent screening studies in human newborns. The guinea pig may be a good animal model in which to compare different diagnostic assays for congenital CMV infection.

  19. The effect of saliva on the fate of nanoparticles.

    Science.gov (United States)

    Teubl, Birgit J; Stojkovic, Biljana; Docter, Dominic; Pritz, Elisabeth; Leitinger, Gerd; Poberaj, Igor; Prassl, Ruth; Stauber, Roland H; Fröhlich, Eleonore; Khinast, Johannes G; Roblegg, Eva

    2018-03-01

    The design of nanocarriers for local drug administration to the lining mucosa requires a sound knowledge of how nanoparticles (NPs) interact with saliva. This contact determines whether NPs agglomerate and become immobile due to size- and interaction-filtering effects or adsorb on the cell surface and are internalized by epithelial cells. The aim of this study was to examine the behavior of NPs in saliva considering physicochemical NP properties. The salivary pore-size distribution was determined, and the viscosity of the fluid inside of the pores was studied with optical tweezers. Distinct functionalized NPs (20 and 200 nm) were dispersed in saliva and salivary buffers and characterized, and surface-bound MUC5B and MUC7 were analyzed by 1D electrophoresis and immunoblotting. NP mobility was recorded, and cellular uptake studies were performed with TR146 cells. The mode diameter of the salivary mesh pores is 0.7 μm with a peak width of 1.9 μm, and pores are filled with a low-viscosity fluid. The physicochemical properties of the NPs affected the colloidal stability and mobility: compared with non-functionalized particles, which did not agglomerate and showed a cellular uptake rate of 2.8%, functionalized particles were immobilized, which was correlated with agglomeration and increased binding to mucins. The present study showed that the salivary microstructure facilitates NP adsorption. However, NP size and surface functionalization determine the colloidal stability and cellular interactions. The sound knowledge of NP interactions with saliva enables the improvement of current treatment strategies for inflammatory oral diseases.

  20. Real-time PCR quantification of six periodontal pathogens in saliva samples from healthy young adults.

    Science.gov (United States)

    Zhou, Xiaodong; Liu, Xiaoli; Li, Jing; Aprecio, Raydolfo M; Zhang, Wu; Li, Yiming

    2015-05-01

    The use of saliva as a diagnostic fluid for the evaluation of periodontal health has gained attention recently. Most published real-time PCR assays focused on quantification of bacteria in subgingival plaque, not in saliva. The aims of this study were to develop a real-time PCR assay for quantification of six periodontal pathogens in saliva and to establish a relationship between the amount of DNA (fg) and colony-forming unit (CFU). TaqMan primers/probe sets were used for the detection of Aggregatibacter actinomycetemcomitans (Aa), Eikenella corrodens (Ec), Fusobacterium nucleatum (Fn), Porphyromonas gingivalis (Pg), Prevotella intermedia (Pi), Tannerella forsythia (Tf), and total bacteria. Six periodontal pathogens and total bacteria in saliva from 24 periodontally healthy individuals were determined. The relationship between the amount of DNA (fg) and CFU was established by measuring the concentrations of extracted bacterial DNA and CFU per milliliter of bacteria on agar plates. Fn, Ec, and Pi were detected in all saliva samples, while 58.5, 45.8, and 33.3% were detected for Tf, Pg, and Aa, respectively. Numbers of Ec and Fn in saliva were highly correlated (R(2) = 0.93, P periodontal pathogens in saliva and estimate the number of live bacteria (CFU). This real-time PCR assay in combination with the relationship between DNA (fg) and CFU has the potential to be an adjunct in evaluation of periodontal health status.

  1. Saliva oxytocin measures do not reflect peripheral plasma concentrations after intranasal oxytocin administration in men.

    Science.gov (United States)

    Quintana, Daniel S; Westlye, Lars T; Smerud, Knut T; Mahmoud, Ramy A; Andreassen, Ole A; Djupesland, Per G

    2018-05-16

    Oxytocin plays an important role in social behavior. Thus, there has been significant research interest for the role of the oxytocin system in several psychiatric disorders, and the potential of intranasal oxytocin administration to treat social dysfunction. Measurement of oxytocin concentrations in saliva are sometimes used to approximate peripheral levels of oxytocin; however, the validity of this approach is unclear. In this study, saliva and plasma oxytocin was assessed after two doses of Exhalation Delivery System delivered intranasal oxytocin (8 IU and 24 IU), intravenous oxytocin (1 IU) and placebo in a double-dummy, within-subjects design with men. We found that intranasal oxytocin (8 IU and 24 IU) administration increased saliva oxytocin concentrations in comparison to saliva oxytocin concentration levels after intravenous and placebo administration. Additionally, we found that saliva oxytocin concentrations were not significantly associated with plasma oxytocin concentrations after either intranasal or intravenous oxytocin administration. Altogether, we suggest that saliva oxytocin concentrations do not accurately index peripheral oxytocin after intranasal or intravenous oxytocin administration, at least in men. The data indicates that elevated oxytocin saliva levels after nasal delivery primarily reflect exogenous administered oxytocin that is cleared from the nasal cavity to the oropharynx, and is therefore a weak surrogate for peripheral blood measurements. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. The Y4-RNA fragment, a potential diagnostic marker, exists in saliva

    Directory of Open Access Journals (Sweden)

    Tatsuya Ishikawa

    2017-06-01

    Full Text Available The 94-nt full-length Y4-RNA is thought to have roles in the initiation of DNA replication and RNA quality control. Although its 31/32-nt fragment also exists abundantly in plasma, little is known about its physiological role. Since the 31/32-nt Y4-RNA fragment in sera is reported to be more abundant in patients with coronary artery disease than healthy persons, the fragment may have a potential for a diagnostic and/or prognostic biomarker for some diseases regardless of its functionality. As a step toward further investigation of its potential utility, we examined if the 31/32-nt Y4-RNA fragment also exists in saliva that can be obtained noninvasively, and showed that, in addition to the 31/32-nt fragment, 14- and 11-nt Y4-RNA fragments are present in all saliva RNA samples from four healthy persons. We established a PCR method to accurately quantitate the amount of the 31/32-nt Y4-RNA fragment, and estimated its amount in saliva of healthy persons to be 0.06 ± 0.04 fmol per nanogram of saliva RNA. We also tried to develop an easier quantitation method using a DNA molecular beacon. Keywords: Y4-RNA fragment, Saliva RNA, Diagnostic/prognostic marker, Next-generation sequencing, RT-PCR, Molecular beacon

  3. Levels of saliva cotinine in electronic cigarette users.

    Science.gov (United States)

    Etter, Jean-François

    2014-05-01

    To assess saliva cotinine levels in experienced users of e-cigarettes ('vapers'). An internet survey in 2011 and 2012, with collection of saliva vials by mail. Participants were 71 users of e-cigarettes enrolled mainly on websites and online forums dedicated to e-cigarettes. Use of e-cigarettes, tobacco and nicotine medications. Collection of saliva by mail and analysis of cotinine by liquid chromatography-mass spectrometry. Most participants (89%) were former smokers, most (92%) were using e-cigarettes daily, had been using e-cigarettes for 12 months on average and puffed a median of 150 times per day on their e-cigarettes [mean = 220 puffs/day, 95% confidence interval (CI) = 169-271]. The median concentration of nicotine in refill liquids was 16 mg/ml (mean = 16.4, 95% CI = 14.5-18.3). In the 62 e-cigarette users who, in the past 5 days, had not used any tobacco or nicotine medications, the median cotinine level was 353 ng/ml (mean = 374, 95% CI = 318-429), the correlation between cotinine and nicotine concentration in e-liquids was r = 0.33 (P = 0.013), and the correlation between cotinine and the number of cigarettes smoked per day before quitting smoking was r = 0.48 (P Addiction.

  4. Analysis for drugs in saliva and breath

    Science.gov (United States)

    1981-09-25

    Collection devices for saliva and breath that involved non-invasive techniques for sample collection were evaluated. Having subjects simply spit into a specially prepared glass vial was found to be an efficient, inexpensive and simple way to collect ...

  5. Analysis for drug in saliva and breath

    Science.gov (United States)

    1981-09-25

    Collection devices for saliva and breath that involved non-invasive : techniques for sample collection were evaluated. Having subjects simply : spit into a specially prepared glass vial was found to be an efficient, : inexpensive and simple way to co...

  6. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    Science.gov (United States)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  7. Saliva and gastrointestinal functions of mastication, taste and textural perception, swallowing and initial digestion

    DEFF Research Database (Denmark)

    Pedersen, Anne Marie Lynge; Sørensen, Christiane E; Proctor, Gordon

    2018-01-01

    pattern. This review paper provides insight into the mechanisms by which saliva acts in relation to taste, mastication, bolus formation, enzymatic digestion, and swallowing. Also the protective functions of saliva including maintenance of dental and mucosal integrity will be discussed as they indirectly......Saliva exerts multiple functions in relation to the initial digestive processes taking place in the upper parts of the gastrointestinal tract. Ingestion of food and beverages, in turn, is a strong stimulus for secretion of saliva with a differential composition depending on the neuronal stimulation...... influence the digestive process. The final part of this paper focuses on the implications of xerostomia and salivary gland dysfunction on gastrointestinal functions. This article is protected by copyright. All rights reserved....

  8. Effect of saliva contamination on bond strength witha hydrophilic composite resin

    Directory of Open Access Journals (Sweden)

    Mauren Bitencourt Deprá

    2013-02-01

    Full Text Available OBJECTIVE: To evaluate the influence of saliva contamination on the bond strength of metallic brackets bonded to enamel with hydrophilic resin composite. METHODS: Eighty premolars were randomly divided into 4 groups (n = 20 according to bonding material and contamination: G1 bonded with Transbond XT with no saliva contamination, G2 bonded with Transbond XT with saliva contamination, G3 bonded with Transbond Plus Color Change with no saliva contamination and G4 bonded with Transbond Plus Color Change with saliva contamination. The results were statistically analyzed (ANOVA/Tukey. RESULTS: The means and standard deviations (MPa were: G110.15 ± 3.75; G2 6.8 ± 2.54; G3 9.3 ± 3.36; G4 8.3 ± 2.95. The adhesive remnant index (ARI ranged between 0 and 1 in G1 and G4. In G2 there was a prevalence of score 0 and similar ARI distribution in G3. CONCLUSION: Saliva contamination reduced bond strength when Transbond XT hydrophobic resin composite was used. However, the hydrophilic resin Transbond Plus Color Change was not affected by the contamination.OBJETIVO: avaliar a influência da contaminação por saliva na resistência de união de braquetes metálicos colados ao esmalte com um compósito resinoso hidrofílico. MÉTODOS: oitenta pré-molares foram divididos aleatoriamente em quatro grupos (n=20, de acordo com o material de colagem e a presença de contaminação - G1 colagem com Transbond XT na ausência de contaminação; G2 colagem com Transbond XT na presença de contaminação; G3 colagem com Transbond Plus Color Change na ausência de contaminação; G4 colagem com Transbond Plus Color Change na presença de contaminação. Os resultados foram tratados estatisticamente (ANOVA/Tukey. RESULTADOS: as médias e desvios-padrão (MPa foram G1 = 10,15 ± 3,75; G2 = 6,8 ± 2,54; G3 = 9,3 ± 3,36; G4 = 8,3 ± 2,95. O índice de adesivo remanescente (IAR variou entre 0 e 1 no G1 e no G4; no G2, houve predomínio do escore 0 e distribuição similar no

  9. Quantitative study of non-stimulated human whole saliva using NAA

    International Nuclear Information System (INIS)

    Lewgoy, H.R.; Zamboni, C.B.; Sabrina Metairon; Medeiros, I.M.M.A.; Medeiros de, J.A.G.

    2013-01-01

    In the past few years, the use of saliva has increased as a method for diagnosis of a variety of diseases. Investigations of flow rates, pH, molecular components, hormones and proteins have presented significant progress in clinical testing as a diagnostic tool. Inorganic elements found in saliva also have important correlations that can assist in the diagnosis of periodontal disease, but these salivary components are still poorly investigated. In this study, we investigated non-stimulated whole saliva of 44 healthy subjects and 12 patients with periodontal disease, obtained from donors at Sao Paulo city (Brazil). Using neutron activation analysis (NAA) technique, we found considerable metabolic changes in the salivary composition of periodontal patients: abnormal concentrations of Br, Ca, I, K, Mg and S that may be associated with periodontal, with the most effective indicator of periodontal disease being Ca concentration. The data from healthy donors also provide a scientific basis for biomedical researches of other oral diseases. (author)

  10. Incidence of Epstein-Barr Virus in Astronaut Saliva During Spaceflight

    Science.gov (United States)

    Payne, Deborah A.; Mehta, Satish K.; Tyring, Stephen K.; Stowe, Raymond P.; Pierson, Duane L.

    1998-01-01

    Astronauts experience psychological and physical stresses that may result in re-activation of latent viruses during spaceflight, potentially increasing the risk of disease among crew members. The shedding of Epstein-Barr virus (EBV) in the saliva of astronauts will increase during spaceflight. A total of 534 saliva specimens were collected from 11 EBV-seropositive astronauts before, during, and after four space shuttle missions. The presence of EBV DNA in saliva, assessed by polymerase chain reaction (PCR), was used to determine shedding patterns before, during, and after spaceflight. EBV DNA was detected more frequently before flight than during (p less than 0.001) or after (p less than 0.01) flight. No significant difference between the in-flight and postflight periods was detected in the frequency of occurrence of EBV DNA. The increased frequency of shedding of EBV before flight suggests that stress levels may be greater before launch than during or after spaceflight.

  11. Improving ambulatory saliva-sampling compliance in pregnant women: a randomized controlled study.

    Directory of Open Access Journals (Sweden)

    Julian Moeller

    Full Text Available OBJECTIVE: Noncompliance with scheduled ambulatory saliva sampling is common and has been associated with biased cortisol estimates in nonpregnant subjects. This study is the first to investigate in pregnant women strategies to improve ambulatory saliva-sampling compliance, and the association between sampling noncompliance and saliva cortisol estimates. METHODS: We instructed 64 pregnant women to collect eight scheduled saliva samples on two consecutive days each. Objective compliance with scheduled sampling times was assessed with a Medication Event Monitoring System and self-reported compliance with a paper-and-pencil diary. In a randomized controlled study, we estimated whether a disclosure intervention (informing women about objective compliance monitoring and a reminder intervention (use of acoustical reminders improved compliance. A mixed model analysis was used to estimate associations between women's objective compliance and their diurnal cortisol profiles, and between deviation from scheduled sampling and the cortisol concentration measured in the related sample. RESULTS: Self-reported compliance with a saliva-sampling protocol was 91%, and objective compliance was 70%. The disclosure intervention was associated with improved objective compliance (informed: 81%, noninformed: 60%, F(1,60  = 17.64, p<0.001, but not the reminder intervention (reminders: 68%, without reminders: 72%, F(1,60 = 0.78, p = 0.379. Furthermore, a woman's increased objective compliance was associated with a higher diurnal cortisol profile, F(2,64  = 8.22, p<0.001. Altered cortisol levels were observed in less objective compliant samples, F(1,705  = 7.38, p = 0.007, with delayed sampling associated with lower cortisol levels. CONCLUSIONS: The results suggest that in pregnant women, objective noncompliance with scheduled ambulatory saliva sampling is common and is associated with biased cortisol estimates. To improve sampling compliance, results suggest

  12. The management of xerostomia in patients on haemodialysis: comparison of artificial saliva and chewing gum.

    Science.gov (United States)

    Bots, Casper P; Brand, Henk S; Veerman, Enno C I; Valentijn-Benz, Marianne; Van Amerongen, Barbara M; Nieuw Amerongen, Arie V; Valentijn, Robert M; Vos, Pieter F; Bijlsma, Joost A; Bezemer, Pieter D; ter Wee, Piet M

    2005-04-01

    Many patients on haemodialysis (HD) therapy suffer from a dry mouth and xerostomia. This can be relieved by mechanical and gustatory stimulation or palliative care. The aim of this crossover study was to investigate the effect and preferences of a sugar-free chewing gum (Freedent White) and a xanthan gum-based artificial saliva (Xialine) in the management of xerostomia in chronic HD patients. Sixty-five HD patients participated in a 6-week crossover trial. The artificial saliva was rated significantly lower than the chewing gum for effectiveness, taste and a global assessment. No preference differences were found for gender and age, although older subjects rated the artificial saliva with a higher mark. Thirty-nine subjects (60%) preferred chewing gum, 15% (n=10) preferred the artificial saliva. Therefore, both chewing gum and artificial saliva could play an important role in the palliative care of xerostomia in HD patients.

  13. The performance of fully automated urine analysis results for predicting the need of urine culture test

    Directory of Open Access Journals (Sweden)

    Hatice Yüksel

    2014-06-01

    Full Text Available Objectives: Urinalysis and urine culture are most common tests for diagnosis of urinary tract infections. The aim of our study is to examine the diagnostic performance of urine analysis and the role of urine analysis to determine the requirements for urine culture. Methods: Urine culture and urine analysis results of 362 patients were retrospectively analyzed. Culture results were taken as a reference for chemical and microscopic examination of urine and diagnostic accuracy of the test parameters, that may be a marker for urinary tract infection, and the performance of urine analysis were calculated for predicting the urine culture requirements. Results: A total of 362 urine culture results of patients were evaluated and 67% of them were negative. The results of leukocyte esterase and nitrite in chemical analysis and leukocytes and bacteria in microscopic analysis were normal in 50.4% of culture negative urines. In diagnostic accuracy calculations, leukocyte esterase (86.1% and microscopy leukocytes (88.0% were found with high sensitivity, nitrite (95.4% and bacteria (86.6% were found with high specificity. The area under the curve was calculated as 0.852 in ROC analysis for microscopic examination for leukocytes. Conclusion: Full-automatic urine devices can provide sufficient diagnostic accuracy for urine analysis. The evaluation of urine analysis results in an effective way can predict the necessity for urine culture requests and especially may contribute to a reduction in the work load and cost. J Clin Exp Invest 2014; 5 (2: 286-289

  14. Urine Tests (For Parents)

    Science.gov (United States)

    ... the urine sample. In certain situations, a sterile bag can be placed around a baby’s diaper area to collect a urine sample. If you have any questions about urine tests, talk with your doctor. Reviewed by: Yamini Durani, MD ...

  15. Development of a Zika Virus Infection Model in Cynomolgus Macaques

    Directory of Open Access Journals (Sweden)

    Fusataka Koide

    2016-12-01

    Full Text Available Limited availability of Indian rhesus macaques (IRM is a bottleneck to study Zika virus (ZIKV pathogenesis and evaluation of appropriate control measures in non-human primates. To address these issues, we report here the Mauritian cynomolgus macaque (MCM model for ZIKV infection. In brief, six MCMs (seronegative for dengue and ZIKV were subdivided into 3 cohorts with a male and female each and challenged with different doses of Asian PRVABC59 (Puerto Rico or FSS13025 (Cambodia or African (IBH30656 lineage ZIKV isolates. Clinical signs were monitored; and biological fluids (serum, saliva and urine and tissues (testes and brain were assessed for viral load by quantitative RT-PCR and neutralizing antibodies (Nab by 50% Plaque Reduction Neutralization Test (PRNT50 at various times post infection (p.i. PRVABC59 induced viremia detectable up to day 10, with peak viral load at 2 to 3 days p.i. An intermittent viremia spike was observed on day 30 with titers reaching 2.5 ×103 genomes/mL. Moderate viral load was observed in testes, urine and saliva. In contrast, FSS13025 induced viremia lasting only up to 6 days and detectable viral loads in testes but not in urine and saliva. Recurrent viremia was detected but at lower titers compare to PRVABC59. Challenge with either PRVABC59 or FSS13025 resulted in 100% seroconversion; with mean PRNT50 titers ranging from 597 to 5179. IBH30656 failed to establish infection in MCM suggesting that MCM are susceptible to infection with ZIKV isolates of the Asian lineage but not from Africa. Due to the similarity of biphasic viremia and Nab responses between MCM and IRM models, MCM could be a suitable alternative for evaluation of ZIKV vaccine and therapeutic candidates.

  16. Microbial profile comparisons of saliva, pooled and site-specific subgingival samples in periodontitis patients.

    Directory of Open Access Journals (Sweden)

    Daniel Belstrøm

    Full Text Available The purpose of this study was to compare microbial profiles of saliva, pooled and site-specific subgingival samples in patients with periodontitis. We tested the hypotheses that saliva can be an alternative to pooled subgingival samples, when screening for presence of periopathogens.Site specific subgingival plaque samples (n = 54, pooled subgingival plaque samples (n = 18 and stimulated saliva samples (n = 18 were collected from 18 patients with generalized chronic periodontitis. Subgingival and salivary microbiotas were characterized by means of HOMINGS (Human Oral Microbe Identification using Next Generation Sequencing and microbial community profiles were compared using Spearman rank correlation coefficient.Pronounced intraindividual differences were recorded in site-specific microbial profiles, and site-specific information was in general not reflected by pooled subgingival samples. Presence of Porphyromonas gingivalis, Treponema denticola, Prevotella intermedia, Filifactor alocis, Tannerella forsythia and Parvimona micra in site-specific subgingival samples were detected in saliva with an AUC of 0.79 (sensitivity: 0.61, specificity: 0.94, compared to an AUC of 0.76 (sensitivity: 0.56, specificity: 0.94 in pooled subgingival samples.Site-specific presence of periodontal pathogens was detected with comparable accuracy in stimulated saliva samples and pooled subgingival plaque samples. Consequently, saliva may be a reasonable surrogate for pooled subgingival samples when screening for presence of periopathogens. Future large-scale studies are needed to confirm findings from this study.

  17. Interactions between resin monomers and commercial composite resins with human saliva derived esterases.

    Science.gov (United States)

    Jaffer, F; Finer, Y; Santerre, J P

    2002-04-01

    Cholesterol esterase (CE) and pseudocholinesterase (PCE) have been reported to degrade commercial and model composite resins containing bisphenylglycidyl dimethacrylate (BisGMA), triethylene glycol dimethacrylate (TEGDMA) or the latter in combination with urethane modified BisGMA monomer systems. In addition, human saliva has been shown to contain esterase like activities similar to CE and PCE. Hence, it was the aim of the current study to determine to what extent human saliva could degrade two common commercial composite resins (Z250 from 3M Inc. and Spectrum TPH from L.D. Caulk) which contain the above monomer systems. Saliva samples from different volunteers were collected, processed, pooled, and freeze-dried. TEGDMA and BisGMA monomers were incubated with human saliva derived esterase activity (HSDEA) and their respective hydrolysis was monitored using high performance liquid chromatography (HPLC). Both monomers were completely hydrolyzed within 25 h by HSDEA. Photopolymerized composites were incubated with buffer or human saliva (pH 7.0 and 37 C) for 2, 8 and 16 days. The incubation solutions were analyzed using HPLC and mass spectrometry. Surface morphology characterization was carried out using scanning electron microscopy. Upon biodegradation, the Z250 composite yielded higher amounts of BisGMA and TEGDMA related products relative to the TPH composite. However, there were higher amounts of ethoxylated bis-phenol A released from the TPH material. In terms of total mass of products released, human saliva demonstrated a greater ability to degrade Z250. In summary, HSDEA has been shown to contain esterase activities that can readily catalyze the biodegradation of current commercial composite resins.

  18. Analysis of urine composition in type Ⅱ diabetic mice after intervention therapy using holothurian polypeptides

    Science.gov (United States)

    Li, Yanyan; Xu, Jiajie; Su, Xiurong

    2017-07-01

    Hydrolysates and peptide fractions (PF) obtained from sea cucumber with commercial enzyme were studied on the hpyerglycemic and renal protective effects on db/db rats using urine metabolomics. Compared with the control group the polypeptides from the two species could significantly reduce the urine glucose and urea. We also tried to address the compositions of highly expressed urinary proteins using a proteomics approach. They were serum albumins, AMBP proteins, negative trypsin, elastase and urinary protein, GAPDH, a receptor of urokinase-type plasminogen activator (uPAR), and Ig kappa chain C region. We used the electronic nose to quickly detect changes in the volatile substances in mice urine after holothurian polypeptides fed, and the results show it can identify the difference between treatment groups with the control group without overlapping. The protein express mechanism of holothurian polypeptides treating diabetes was discussed, and we suggested these two peptides with the hypoglycemic and renal protective activity might be utilized as nutraceuticals.

  19. Analysis of Urine Composition in Type II Diabetic Mice after Intervention Therapy Using Holothurian Polypeptides

    Directory of Open Access Journals (Sweden)

    Yanyan Li

    2017-07-01

    Full Text Available Hydrolysates and peptide fractions (PF obtained from sea cucumber with commercial enzyme were studied on the hyperglycemic and renal protective effects on db/db rats using urine metabolomics. Compared with the control group the polypeptides from the two species could significantly reduce the urine glucose and urea. We also tried to address the compositions of highly expressed urinary proteins using a proteomics approach. They were serum albumins, AMBP proteins, negative trypsin, elastase, and urinary protein, GAPDH, a receptor of urokinase-type plasminogen activator (uPAR, and Ig kappa chain C region. We used the electronic nose to quickly detect changes in the volatile substances in mice urine after holothurian polypeptides (HPP fed, and the results show it can identify the difference between treatment groups with the control group without overlapping. The protein express mechanism of HPP treating diabetes was discussed, and we suggested these two peptides with the hypoglycemic and renal protective activity might be utilized as nutraceuticals.

  20. Kadar leptin saliva dan kejadian karies gigi anak obesitas (Salivary leptin levels and caries incidence in obese children

    Directory of Open Access Journals (Sweden)

    Elfrida Atzmaryanni

    2013-09-01

    Full Text Available Background: Children with obesity have a lower incidence of caries. Salivary leptin levels of obese children is higher than normal children. Leptin is protein hormone, contained in saliva. Salivary proteins maintain the balance of the ecosystem in the mouth. Purpose: The article was aimed to study the correlation of salivary leptin levels with caries incidence in obese children. Review: Mouth is reflection of the health status and so many changes occur as a weight gain. Child with obesity has a low incidence of caries than normal. This condition is associated with changes in oral cavity, especially the increase in salivary leptin. Caries is a disease of hard tissues cause by the activty of microorganisms, especially Streptococcus mutans. Salivary proteins maintain the balance of the ecosystem in the mouth. Leptin is a protein saliva, produced predominantly in adipose tissue and conduct active transport to saliva. Salivary leptin works in two ways: as an antimicrobial which prevents the attachment of bacteria on tooth surface or by inducing cytokine that affect the immune system in oral cavity. Conclusion: Salivary leptin is higher in obese children than in normal children. The low incidence of caries on obesity is associated with salivary leptin. Alteration in salivary composition and flow rate also decreased caries in obesity.Latar belakang: Anak yang mengalami obesitas memiliki insiden karies yang rendah. Kadar leptin saliva anak obesitas lebih tinggi dari anak normal. Leptin merupakan salah satu protein hormon yang terdapat di saliva. Protein saliva berfungsi untuk menjaga keseimbangan ekosistem di mulut. Tujuan: Artikel ini bertujuan mempelajari hubungan antara kadar leptin di dalam saliva dengan kejadian karies anak obesitas. Tinjauan pustaka: Rongga mulut merupakan cerminan dari status kesehatan dan banyak perubahan yang terjadi seiring peningkatan berat badan seseorang. Anak Obesitas memiliki insiden karies yang rendah jika dibandingkan

  1. Serum cystatin C and urinary neutrophil gelatinase-associated lipocalin in pediatric acute kidney injury; a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Neamatollah Ataei

    2017-10-01

    Full Text Available Background: Acute kidney injury (AKI refers to insults that lead to decreased kidney function within hours to weeks and can be associated with complications including chronic kidney failure, end-stage renal disease and even death. Although various biomarkers have been proposed to predict AKI in children, but no consensus has been reached on the best diagnostic method. Accordingly, the present study aimed to assess the correlation between urine NGAL levels and development of AKI in children and determine which one of the biomarkers of urine NGAL, serum Cystatin C and serum creatinine has a stronger association with AKI in the pediatric population. Methods: The present cross-sectional study was conducted on children younger than 14 years of age, hospitalized in the intensive care unit of Children’s Medical Centre in Tehran, Iran, during 2016. Urine NGAL, serum Cystatin C and serum creatinine levels of these subjects were measured on admission to the intensive care unit. The concentrations of serum Cystatin C and serum creatinine were measured again after 48 hours to determine the AKI status of the subjects. Data were analyzed to determine the association between GFR and the concentrations of evaluated biomarkers and to compare the levels of biomarkers between the four groups of no AKI, injury, failure, loss and end-stage. Results: A total of 104 children (59 boys and 45 girls, average age=28.0±3.5 months were included in this study. The mean level of uNGAL on admission in the No-AKI group (153.79±29.82 was significantly lower than the children in the injury (1225.0 ±275.0 and failure (756.56±147.79 groups (df:3, 100; F=10.74; p<0.0001. The mean concentration of Cystatin C on admission in the three groups of risk (0.94±0.30, injury (1.75±0.05 and failure (1.75±0.36 was also significantly higher than the No-AKI (0.27±0.04 (df:3, 100; F=19.21; p<0.0001. However, there was no significant correlation between the level of serum creatinine on

  2. Application of ICP-OES to the determination of barium in blood and urine in clinical and forensic analysis.

    Science.gov (United States)

    Lech, Teresa

    2013-05-01

    Exposure to barium (Ba) mostly occurs in the workplace or from drinking water, but it may sometimes be due to accidental or intentional intoxication. This paper presents a reliable, sensitive method for the determination of Ba in blood and urine: inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave digestion of samples. The overall procedure was checked using Seronorm Whole Blood L-2, Trace Elements Urine and spiked blood and urine samples (0.5-10 µg/mL of Ba). The accuracy of the whole procedure (relative error) was 4% (blood) and 7% (urine); the recovery was 76-104% (blood) and 85-101% (urine). The limits of detection and quantification (Ba λ = 455.403 nm) were 0.11 and 0.4 µg/L of Ba, respectively; precision (relative standard deviation) was below 6% at the level of 15 µg/L of Ba for blood. This method was applied to a case of the poisoning of a man who had been exposed at the workplace for over two years to powdered BaCO3, and who suffered from paralysis and heart disorders. The concentrations of Ba, in μg/L, were 160 (blood), 460 (serum) and 1,458 (urine) upon his admission to the hospital, and 6.1 (blood) and 4.9 (urine) after 11 months (reference values: 3.34 ± 2.20 µg/L of Ba for blood and 4.43 ± 4.60 µg/L of Ba for urine).

  3. Effect of masticatory stimulation on the quantity and quality of saliva and the salivary metabolomic profile.

    Directory of Open Access Journals (Sweden)

    Nobuyuki Okuma

    Full Text Available This study characterized the changes in quality and quantity of saliva, and changes in the salivary metabolomic profile, to understand the effects of masticatory stimulation.Stimulated and unstimulated saliva samples were collected from 55 subjects and salivary hydrophilic metabolites were comprehensively quantified using capillary electrophoresis-time-of-flight mass spectrometry.In total, 137 metabolites were identified and quantified. The concentrations of 44 metabolites in stimulated saliva were significantly higher than those in unstimulated saliva. Pathway analysis identified the upregulation of the urea cycle and synthesis and degradation pathways of glycine, serine, cysteine and threonine in stimulated saliva. A principal component analysis revealed that the effect of masticatory stimulation on salivary metabolomic profiles was less dependent on sample population sex, age, and smoking. The concentrations of only 1 metabolite in unstimulated saliva, and of 3 metabolites stimulated saliva, showed significant correlation with salivary secretion volume, indicating that the salivary metabolomic profile and salivary secretion volume were independent factors.Masticatory stimulation affected not only salivary secretion volume, but also metabolite concentration patterns. A low correlation between the secretion volume and these patterns supports the conclusion that the salivary metabolomic profile may be a new indicator to characterize masticatory stimulation.

  4. Simultaneous determination of vinclozolin and detection of its degradation products in mouse plasma, serum and urine, and from rabbit bile, by high-performance liquid chromatography.

    Science.gov (United States)

    Dhananjeyan, Mugunthu R; Erhardt, Paul W; Corbitt, Cynthia

    2006-05-19

    A specific high-performance liquid chromatography method has been developed for simultaneous detection of vinclozolin and its degradation products (M1, M2, and M3). The method has been validated according to ICH guidelines and can be extended to quantitation of vinclozolin. A base-line separation of vinclozolin and its degradation products was found with symmetrical peak shapes on an XTerra MS C18 column using 10 mM ammonium bicarbonate at pH 9.2 and acetonitrile as mobile phase. The retention times of vinclozolin, M1, M2, and M3 were 12.8, 8.1, 11.6, and 11.1 min, respectively. A linear calibration curve was obtained across a range from 5 to 200 microM for vinclozolin. The intra- and inter-day relative standard deviations (%RSD) were vinclozolin from bio-fluids including mouse plasma, serum and urine, and rabbit bile, were obtained in a single step with a single solvent.

  5. Urine Biochemistry in the Early Postoperative Period after Cardiac Surgery: Role in Acute Kidney Injury Monitoring

    Directory of Open Access Journals (Sweden)

    Alexandre Toledo Maciel

    2013-01-01

    Full Text Available We have recently suggested that sequential urine electrolyte measurement in critically ill patients may be useful in monitoring kidney function. Cardiac surgery is one of the leading causes of acute kidney injury (AKI in the intensive care unit (ICU. In this paper, we describe the sequential behavior of urine electrolytes in three patients in the early (first 60 hours postoperative period after cardiac surgery according to AKI status: no AKI, transient AKI, and persistent AKI. We have found that the patient with no AKI had stable and high concentrations of sodium (NaU and chloride (ClU in sequential spot samples of urine. AKI development was characterized in the other two patients by decreases in NaU and ClU, which have started early after ICU admission. Transient AKI was marked by also transient and less severe decreases in NaU and ClU. Persistent AKI was marked by the less favorable clinical course with abrupt and prolonged declines in NaU and ClU values. These electrolytes in urine had a behavior like a “mirror image” in comparison with that of serum creatinine. We suggest that sequential urine electrolytes are useful in monitoring acute kidney injury development in the early postoperative period after cardiac surgery.

  6. Meal-induced compositional changes in blood and saliva in persons with bulimia nervosa

    DEFF Research Database (Denmark)

    Dynesen, Anja Weirsøe; Jensen, Allan Bardow; Astrup, Arne

    2008-01-01

    in controls before and after intake of a meal and whether these changes may be reflected in saliva. Design: Twenty women with bulimia nervosa and 20 age- and sex-matched healthy controls participated. After an overnight fast, the subjects ate a standardized carbohydrate-rich breakfast. Whole saliva and blood...... were collected, and visual analogue scales for hunger and satiety were completed once before and continuously for 5 h after the breakfast. Results: A lower pre- and postprandial whole saliva flow rate was found in subjects with bulimia nervosa, which might have been attributable to a concomitant intake...

  7. Determination of epirubicin and its metabolite epirubicinol in saliva and plasma by HPLC

    NARCIS (Netherlands)

    Dodde, WIW; Maring, JG; Hendriks, G; Wachters, FM; Groen, HJM; de Vries, EGE; Uges, DRA

    We present a high-performance liquid chromatography (HPLC) method suitable for the analysis of epirubicin and its metabolite epirubicinol in saliva and plasma. Preparation of saliva and plasma samples was performed by extraction of analytes with a chloroform: 2-propanol mixture (6:1, vol/vol) and

  8. Corticosteroids in plasma and saliva : the influence of oral contraceptive use and pregnancy

    NARCIS (Netherlands)

    Meulenberg, E.P.M.M.

    1995-01-01

    Cortisol in saliva is considered to be derived from the free, unbound fraction in plasma by simple diffusion through the salivary gland. Despite considerable conversion into cortisone in the salivary gland by the enzyme 11β-hydroxysteroid dehydrogenase, levels of cortisol in saliva form a

  9. Fluoride level in saliva after bonding orthodontic brackets with a fluoride containing adhesive

    NARCIS (Netherlands)

    Ogaard, B; Arends, J; Helseth, H; Dijkman, G; vanderKuijl, M

    The fluoride level in saliva is considered an important parameter in caries prevention. Elevation of the salivary fluoride level by a fluoride-releasing orthodontic bonding adhesive would most likely be beneficial in the prevention of enamel caries. In this study, the fluoride level in saliva was

  10. Effects of moderate-dose versus high-dose trimethoprim on serum creatinine and creatinine clearance and adverse reactions.

    OpenAIRE

    Naderer, O; Nafziger, A N; Bertino, J S

    1997-01-01

    The effects of a 10-day course of moderate-dose (10 mg/kg/day) or high-dose (20 mg/kg/day) trimethoprim therapy on serum creatinine, measured creatinine clearance, urinary creatinine excretion, and serum folate were studied in 20 healthy volunteers. Serum creatinine concentrations increased significantly during trimethoprim therapy, began to decrease near day 10, and returned to baseline during the washout phase at both dosage levels. At the same time, measured creatinine clearance and urine ...

  11. Fourier Transform Infrared Spectroscopy and Photoacoustic Spectroscopy for Saliva Analysis.

    Science.gov (United States)

    Mikkonen, Jopi J W; Raittila, Jussi; Rieppo, Lassi; Lappalainen, Reijo; Kullaa, Arja M; Myllymaa, Sami

    2016-09-01

    Saliva provides a valuable tool for assessing oral and systemic diseases, but concentrations of salivary components are very small, calling the need for precise analysis methods. In this work, Fourier transform infrared (FT-IR) spectroscopy using transmission and photoacoustic (PA) modes were compared for quantitative analysis of saliva. The performance of these techniques was compared with a calibration series. The linearity of spectrum output was verified by using albumin-thiocyanate (SCN(-)) solution at different SCN(-) concentrations. Saliva samples used as a comparison were obtained from healthy subjects. Saliva droplets of 15 µL were applied on the silicon sample substrate, 6 drops for each specimen, and dried at 37 ℃ overnight. The measurements were carried out using an FT-IR spectrometer in conjunction with an accessory unit for PA measurements. The findings with both transmission and PA modes mirror each other. The major bands presented were 1500-1750 cm(-1) for proteins and 1050-1200 cm(-1) for carbohydrates. In addition, the distinct spectral band at 2050 cm(-1) derives from SCN(-) anions, which is converted by salivary peroxidases to hypothiocyanate (OSCN(-)). The correlation between the spectroscopic data with SCN(-) concentration (r > 0.990 for transmission and r = 0.967 for PA mode) was found to be significant (P < 0.01), thus promising to be utilized in future applications. © The Author(s) 2016.

  12. Artificial saliva effect on toxic substances release from acrylic resins

    Directory of Open Access Journals (Sweden)

    Kostić Milena

    2015-01-01

    Full Text Available Background/Aim. Acrylic-based resins are intensively used in dentistry practice as restorative or denture-base materials. The purpose of this study was to analyze the surface structure of denture base resins and the amount of released potentially toxic substances (PTS immediately upon polymerization and incubation in different types of artificial saliva. Methods. Storage of acrylic samples in two models of artificial saliva were performed in a water bath at the temperature of 37 ± 1°C. Analysis of the surface structure of samples was carried out using scanning electronic microscopy analysis immediately after polymerization and after the 30-day incubation. The amounts of PTS per day, week and month extracts were measured using high-pressure liquid chromatography. Results. Surface design and amount of PTS in acrylic materials were different and depended on the types and duration of polymerization. The surfaces of tested acrylates became flatter after immersing in solutions of artificial saliva. The degree of acrylic materials release was not dependent on the applied model of artificial saliva. Conclusion. In order to improve biological features of acrylic resin materials, it was recommended that dentures lined with soft or hard coldpolymerized acrylates should be kept at least 1 to 7 days in water before being given to a patient. So, as to reach high degree of biocompatibility preparation of prosthetic restorations from heat-polymerized acrylate was unnecessary. [Projekat Ministarstva nauke Republike Srbije, br. 41017

  13. Association of Serum Adropin Concentrations with Diabetic Nephropathy

    Directory of Open Access Journals (Sweden)

    Wenchao Hu

    2016-01-01

    Full Text Available Objective. Adropin is a newly identified regulatory protein encoded by the Enho gene and is critically involved in energy homeostasis and insulin sensitivity. This study aims to determine the correlation of serum adropin concentrations with diabetic nephropathy (DN. Methods. This study consisted of 245 patients with type 2 diabetes mellitus (T2DM and 81 healthy subjects. Then T2DM patients were divided into normoalbuminuria, microalbuminuria, and macroalbuminuria subgroups based on urine albumin to creatinine ratio (ACR. Results. T2DM patients showed significantly lower serum adropin concentrations than those in the controls. T2DM patients with macroalbuminuria had significantly decreased serum adropin concentrations compared with the other three groups. In addition, T2DM patients with microalbuminuria showed lower serum adropin concentrations than those in patients with normoalbuminuria. Logistic regression analysis showed that serum adropin was correlated with decreased risk of developing T2DM and DN. Pearson correlation analysis indicated that serum adropin was negatively correlated with body mass index (BMI, blood urea nitrogen, creatinine, and ACR and positively correlated with glomerular filtration rate. Furthermore, multiple linear regression analysis showed that BMI and ACR were negatively correlated with serum adropin levels. Conclusion. Serum adropin concentrations are negatively associated with renal function. Adropin may be implicated in the pathogenesis of DN development.

  14. A Qualitative Review on the Pharmacokinetics of Antibiotics in Saliva: Implications on Clinical Pharmacokinetic Monitoring in Humans.

    Science.gov (United States)

    Kiang, Tony K L; Ensom, Mary H H

    2016-03-01

    We conducted a systematic search to describe the current state of knowledge regarding the utility of saliva for clinical pharmacokinetic monitoring (CPM) of antibiotics. Although the majority of identified studies lacked sufficient pharmacokinetic data needed to assign an appropriate suitability classification, most aminoglycosides, fluoroquinolones, macrolides, penicillins/cephalosporins, and tetracyclines are likely not suitable for CPM in saliva. No clear pattern of correlation was observed between physiochemical properties that favor drug distribution into saliva and the likelihood of the antibiotic being classified as suitable for CPM in saliva (and vice versa). Insufficient data were available to determine if pathophysiological conditions affected salivary distribution of antibiotics. Additional confirmatory data are required for drugs (especially in patients) that are deemed likely suitable for CPM in saliva because only a few studies were available and many focused only on healthy subjects. All studies identified had relatively small sample sizes and exhibited large variability. Very few studies reported salivary collection parameters (e.g., salivary flow, pH) that could potentially have some impact on drug distribution into saliva. The available data are heavily weighted on healthy subjects, and insufficient data were available to determine if pathophysiology had effects on saliva drug distribution. Some studies also lacked assay sensitivity for detecting antibiotics in saliva. Overall, this review can be useful to clinicians who desire an overview on the suitability of saliva for conducting CPM of specific antibiotics, or for researchers who wish to fill the identified knowledge gaps to move the science of salivary CPM further.

  15. Acid base status in swamp buffaloes (Bubalus Bubalis fed rice straw and concentrate with addition of sodium

    Directory of Open Access Journals (Sweden)

    G Joseph

    2001-12-01

    Full Text Available An experiment was conducted to study the addition of NaHCO3 and Na2CO3 on acid-base status in swamp buffaloes, Three fistulated buffaloes were each introduced to dietary treatment control diett (50% rice straw + 50% concentrate, control + \\0% NaHCO3 and diet control + 10% Na2CO3 in two times Latin Square Design. The diets contained 9,7% crude protein and 53% TDN to achieve maintenance requirements of the animals. Parameters measured include (l Fed consumption, water consumption and urine volume. (2 pH in rumen fluid, saliva, bLood and urine, (3 natrium mineral content in rumen fluid, saliva, blood and urine. The results of the experiment showed higher pH in the rumen fluid, saliva, blood and urine of buffaloes due to supplementation of NaHCO3 and Na2CO3, Water consumption and urine volume was significanly increased as the effect of Na supplement. The acid-base status of buffaloes was apparently normal in all animals.

  16. Zika virus infection spread through saliva – a truth or myth?

    Directory of Open Access Journals (Sweden)

    Walter Luiz SIQUEIRA

    2016-01-01

    Full Text Available Abstract In this Point-of-view article we highlighted some features related to saliva and virus infection, in special for zika virus. In addition, we pointed out the potential oral problems caused by a microcephaly originated by a zika virus infection. In the end the, we demonstrated the importance of a more comprehensive exploration of saliva and their components as a fluid for diagnostic and therapeutic approaches on oral and systemic diseases.

  17. Validity of Serum Cystatin C as an Early and Accurate Marker of Glomerular Filtration Rate in type 1 Diabetes Mellitus Patients

    International Nuclear Information System (INIS)

    Fathy, H.A.; Fathy, M.A.

    2017-01-01

    The present study aims at exploring the clinical validity of measuring cystatin C for the early and accurate assessment of GFR (as compared to measuring serum creatinine or β2 microglobulin) in patients suffering from type 1 diabetes mellitus who are at risk of developing diabetic nephropathy as well as those who have already developed the condition. This study included 80 subjects who were further subdivided into two groups: Control group (1) which comprised 20 healthy age and sex matched children. Patient group (2) comprised 60 patients of both sexes properly diagnosed with type 1 diabetes. The patients were further subdivided into 3 subgroups according albumin levels in their 24 hour urine : Group 2a: 20 patients who were considered normo-albumin uric. Group 2b: 20 patients who were considered micro-albumin uric. Group 2c: 20 patients who were considered macro - albumin uric. All subjects were subjected to the estimation of serum creatinine level as well as serum β2 microglobulin and serum cystatin C levels. They were also subjected to Isotope renogram using "9"9"mTc- diethylene triamine pentaacetic acid (DTPA) single injection technique for accurate measurement of glomerular filtration rate (GFR). A positive correlation was observed between each of serum creatinine, β2 microglobulin, cystatin C with albumin in 24 hr urine in all the patient subgroups and this correlation was highly significant. However, the correlation between serum cystatin C levels in the diabetic patients and albumin in 24 hr urine was higher than that observed for either serum creatinine or serum β2 microglobulin. Cystatin C had the highest negative correlation with GFR (as measured by "9"9"mTc-DTPA clearance) compared to either serum creatinine or serum β 2 microglobulin in group II patients. It can be concluded that cystatin C could act as an early and accurate marker of GFR and renal function in patients with type 1 diabetes mellitus at risk of developing or who have already

  18. Human Elimination of Phthalate Compounds: Blood, Urine, and Sweat (BUS) Study

    Science.gov (United States)

    Genuis, Stephen J.; Beesoon, Sanjay; Lobo, Rebecca A.; Birkholz, Detlef

    2012-01-01

    Background. Individual members of the phthalate family of chemical compounds are components of innumerable everyday consumer products, resulting in a high exposure scenario for some individuals and population groups. Multiple epidemiological studies have demonstrated statistically significant exposure-disease relationships involving phthalates and toxicological studies have shown estrogenic effects in vitro. Data is lacking in the medical literature, however, on effective means to facilitate phthalate excretion. Methods. Blood, urine, and sweat were collected from 20 individuals (10 healthy participants and 10 participants with assorted health problems) and analyzed for parent phthalate compounds as well as phthalate metabolites using high performance liquid chromatography-tandem mass spectrometry. Results. Some parent phthalates as well as their metabolites were excreted into sweat. All patients had MEHP (mono(2-ethylhexyl) phthalate) in their blood, sweat, and urine samples, suggesting widespread phthalate exposure. In several individuals, DEHP (di (2-ethylhexl) phthalate) was found in sweat but not in serum, suggesting the possibility of phthalate retention and bioaccumulation. On average, MEHP concentration in sweat was more than twice as high as urine levels. Conclusions. Induced perspiration may be useful to facilitate elimination of some potentially toxic phthalate compounds including DEHP and MEHP. Sweat analysis may be helpful in establishing the existence of accrued DEHP in the human body. PMID:23213291

  19. A Lab-on-a-Chip-Based Non-Invasive Optical Sensor for Measuring Glucose in Saliva

    Directory of Open Access Journals (Sweden)

    Dong Geon Jung

    2017-11-01

    Full Text Available A lab-on-a-chip (LOC-based non-invasive optical sensor for measuring glucose in saliva was fabricated. Existing glucose sensors utilizing blood require acquisition of a blood sample by pricking the finger, which is painful and inconvenient. To overcome these limitations, we propose a non-invasive glucose sensor with LOC, micro-electro-mechanical system and optical measurement technology. The proposed sensor for measuring glucose in saliva involves pretreatment, mixing, and measurement on a single tiny chip. Saliva containing glucose and glucose oxidase for glucose oxidation are injected through Inlets 1 and 2, respectively. Next, H2O2 is produced by the reaction between glucose and glucose oxidase in the pretreatment part. The saliva and generated H2O2 are mixed with a colorizing agent injected through Inlet 3 during the mixing part and the absorbance of the colorized mixture is measured in the measurement part. The absorbance of light increases as a function of glucose concentration at a wavelength of 630 nm. To measure the absorbance of the colorized saliva, a light-emitting diode with a wavelength of 630 nm and a photodiode were used during the measurement part. As a result, the measured output current of the photodiode decreased as glucose concentration in the saliva increased.

  20. Orthodontic treatment effects on inflammatory marker profiles in saliva before and after 2 archwire changes

    Science.gov (United States)

    Yamamoto, Zulham; Jaafar, Ikmal Mohamad; Rohaya, M. A. W.; Abidin, Intan Zarina Zainol; Senafi, Sahidan; Ariffin, Zaidah Zainal; Ariffin, Shahrul Hisham Zainal

    2013-11-01

    Periodontal tissue changes exerted by external forces in orthodontic treatment allow tooth movement. The changes in periodontal tissues i.e. inflammation can be monitored using gingival crevicular fluid (GCF). GCF is a component of saliva. Saliva could be used to monitor periodontal disease progression. The use of saliva to monitor periodontal tissues changes during orthodontic treatment is still unknown. Therefore, we observed the profiles of inflammatory markers namely creatine kinase ('CK), nitric oxide (NO), lactate dehydrogenase (LDH) and aspartate aminotransferase (AST) in saliva of orthodontic patients to evaluate their importance in orthodontic treatment. A total of 21 subjects (13 female and 8 male) participated in this study. Samples were collected from gingival crevicular fluid at three period of archwire changes: baseline (M0), 2 weeks after 0.014" NiTi archwire (M1), and 2 weeks after 0.018" NiTi archwire (M2). All enzyme activities i.e. CK, LDH and AST were measured spectrophotometrically at 340 nm. Griess assay was used to measure nitric oxide level. CK activity, NO level, LDH activity and AST activity in saliva samples did not show significant differences among period of archwire changes. The use of inflammatory marker profiles in saliva may not represent the changes in periodontal tissues during orthodontic treatment.